  1. Measurements of the personal dose equivalent

    International Nuclear Information System (INIS)

    Scarlat, F.; Scarisoreanu, A.; Badita, E.; Oane, M.; Mitru, E.

    2008-01-01

    Full text: The paper presents the results of measurements related to the personal dose equivalent in the rooms adjacent to NILPRP 7 MeV linear accelerator, by means of the secondary standard chamber T34035 Hp(10). The chamber was calibrated by PTB at S- 137 Cs (E av = 661.6 keV, T 1/2 11050 days) and has N H = 3.17x10 6 Sv/C calibration factor for the personal dose equivalent, Hp(10), at a depth of 10 mm in climatic reference conditions. The measurements were made for the two operation mode of the 7 MeV linac: electrons and bremsstrahlung

  2. Skin Dose Equivalent Measurement from Neutron-Deficient Isotopes

    International Nuclear Information System (INIS)

    Hsu, Hsiao-Hua; Costigan, Steve A.; Romero, Leonard L.; Whicker, Jeffrey J.

    1997-12-01

    Neutron-deficient-isotopes decay via positron emission and/or electron capture often followed by x-ray, gamma-ray, and 0.511 MeV photons from positron annihilation. For cases of significant area and/or personnel contamination with these isotopes, determination of skin dose equivalent (SDE) is required by 10CFR835. For assessment of SDE, we evaluated the MICROSPEC-2(TM) system manufactured by Bubble Technology Industries of Canada which uses three different probes for dose measurement. We used two probes: (1) the X-probe which measures lower energy (4 - 120 keV) photon energy distributions and determines deep dose equivalent, SDE and dose equivalent to eyes, and (2) the B-probe which measures electron (positron) energy distributions, and determines skin dose equivalent. Also, the measured photon and beta spectra can be used to identify radioactive isotopes in the contaminated area. Measurements with several neutron-deficient sources showed that this system provided reasonably accurate SDE rate measurements when compared with calculated benchmark SDE rates with an average percent difference of 40%. Variations were expected because of differences between the assumed geometries used by MlCROSPEC-2 and the calculations when compared to the measurement conditions

  3. Skin Dose Equivalent Measurement from Neutron-Deficient Isotopes.

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Hsiao-Hua; Costigan, Steve A.; Romero, Leonard L.; Whicker, Jeffrey J.

    1997-12-31

    Neutron-deficient-isotopes decay via positron emission and/or electron capture often followed by x-ray, gamma-ray, and 0.511 MeV photons from positron annihilation. For cases of significant area and/or personnel contamination with these isotopes, determination of skin dose equivalent (SDE) is required by 10CFR835. For assessment of SDE, we evaluated the MICROSPEC-2(TM) system manufactured by Bubble Technology Industries of Canada which uses three different probes for dose measurement. We used two probes: (1) the X-probe which measures lower energy (4 - 120 keV) photon energy distributions and determines deep dose equivalent, SDE and dose equivalent to eyes, and (2) the B-probe which measures electron (positron) energy distributions, and determines skin dose equivalent. Also, the measured photon and beta spectra can be used to identify radioactive isotopes in the contaminated area. Measurements with several neutron-deficient sources showed that this system provided reasonably accurate SDE rate measurements when compared with calculated benchmark SDE rates with an average percent difference of 40%. Variations were expected because of differences between the assumed geometries used by MlCROSPEC-2 and the calculations when compared to the measurement conditions.

  4. Is the dose equivalent index a quantity to be measured

    International Nuclear Information System (INIS)

    Wagner, S.R.

    1980-01-01

    The following modifying factors are briefly considered in relation to the ambiguities and limitations of the Dose Equivalent Index: 1) Variations with time or of the movement of the exposed person 2) Irradiation geometry 3) Effect of radiation energy 4) Instrument performance and calibration, and other operational quantities. (U.K.)

  5. Measurement of ambient dose equivalent H*(10) and directional dose equivalent H'(0.07) with pocket sized survey meters

    International Nuclear Information System (INIS)

    Iwatschenko, Michael

    2008-01-01

    Full text: In many parts of the world, predominantly in Europe, small sized survey meters based on Geiger-Mueller or proportional counters are widely used for dose rate and dose equivalent rate measurements, while in other regions, especially in the U.S., ionisation chambers are preferred for this task. This paper tries to shed some light on the likely reasons for these two diverging instrumental inclinations. Their respective strengths and weaknesses is analyzed in respect to energy response, dose rate measuring range, size, weight and susceptibility to environmental influences. Furthermore the response and limitations regarding the measurement of pulsed radiation (medical X-ray and CT-devices, accelerators, non-destructive testing) is discussed. A newly developed pocket size instrument based on a pan-cake Geiger-Mueller tube is used as an example to explain the capability and flexibility of modern survey meters. The RadEye B20 is a compact multi-purpose dose rate meter and contamination meter for alpha, beta, gamma and X-ray radiation. By virtue of carefully designed multi-layer gamma energy filters, H*(10) (deep dose) or H'(0,07) (shallow dose) measurements from 17 - 1300 keV can be performed. The instrument can even be worn in a belt holster, so that the impact to the mobility of the user is minimized. For emergency response purposes alpha and beta contamination can be discriminated using another optional filter; a simple sample changer adapter can extend the scope of application. Immediate and reproducible counter measurements, e.g. of smear tests can be performed locally. (author)

  6. The Use Of Optical Properties Of Cr-39 In Alpha Particle Equivalent Dose Measurements

    International Nuclear Information System (INIS)

    Shnishin, K.A.

    2007-01-01

    In this work, optical properties of alpha irradiated Cr-39 were measured as a function of optical photon wavelength from 200-1100 nm. Optical energy gap and optical absorption at finite wavelength was also calculated and correlated to alpha fluence and dose equivalent. Alpha doses were calculated from the corresponding irradiation fluence and specific energy loss using TRIM computer program. It was found that, the optical absorption of unattached Cr-39 was varied with alpha fluence and corresponding equivalent doses. Also the optical energy gab was varied with fluence and dose equivalent of alpha particles. This work introduces a reasonably simple method for the Rn dose equivalent calculation by Cr-39 track

  7. New recommendations for dose equivalent

    International Nuclear Information System (INIS)

    Bengtsson, G.

    1985-01-01

    In its report 39, the International Commission on Radiation Units and Measurements (ICRU), has defined four new quantities for the determination of dose equivalents from external sources: the ambient dose equivalent, the directional dose equivalent, the individual dose equivalent, penetrating and the individual dose equivalent, superficial. The rationale behind these concepts and their practical application are discussed. Reference is made to numerical values of these quantities which will be the subject of a coming publication from the International Commission on Radiological Protection, ICRP. (Author)

  8. Dose equivalent measurements in mixed and time varying radiation fields around high-energy accelerators

    CERN Document Server

    Mayer, S

    2003-01-01

    Measurements of ambient dose equivalent in stray radiation fields behind the shielding of high-energy accelerators are a challenging task. Several radiation components (photons, neutrons, charged particles, muons, etc.), spanning a wide range of energies, contribute to the total dose equivalent. The radiation fields are produced by beam losses interacting with structural material during the acceleration or at the ejection to experimental areas or other accelerators. The particle beam is usually not continuous but separated in "bunches" or pulses, which further complicates dose measurements at high-energy accelerators. An ideal dosimeter for operational radiation protection should measure dose equivalent for any composition of radiation components in the entire energy range even when the field is strongly pulsed. The objective of this work was to find out if an ionisation chamber operated as a "recombination chamber" and a TEPC instrument using the variance-covariance method ("Sievert Instrument") are capable ...

  9. Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS

    Energy Technology Data Exchange (ETDEWEB)

    Benton, E.R. [Eril Research, Inc., Stillwater, Oklahoma (United States); Deme, S.; Apathy, I. [KFKI Atomic Energy Research Institute, Budapest (Hungary)

    2006-07-01

    To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET{sub {infinity}}H{sub 2}O {>=} 10 keV/{mu}m, including the secondaries produced in interactions with high-energy neutrons. Dose information from CR-39 P.N.T.D. is used to correct the absorbed dose component {>=} 10 keV/{mu}m measured in TLD to obtain total dose. Dose equivalent from CR-39 P.N.T.D. is combined with the dose component <10 keV/{mu}m measured in TLD to obtain total dose equivalent. Dose rates ranging from 165 to 250 {mu}Gy/day and dose equivalent rates ranging from 340 to 450 {mu}Sv/day were measured aboard I.S.S. during the Expedition 2 mission in 2001. Results from the P.D.S. are consistent with those from other passive detectors tested as part of the ground-based I.C.C.H.I.B.A.N. intercomparison of space radiation dosimeters. (authors)

  10. Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS

    International Nuclear Information System (INIS)

    Benton, E.R.; Deme, S.; Apathy, I.

    2006-01-01

    To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca 2 SO 4 :Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET ∞ H 2 O ≥ 10 keV/μm, including the secondaries produced in interactions with high-energy neutrons. Dose information from CR-39 P.N.T.D. is used to correct the absorbed dose component ≥ 10 keV/μm measured in TLD to obtain total dose. Dose equivalent from CR-39 P.N.T.D. is combined with the dose component <10 keV/μm measured in TLD to obtain total dose equivalent. Dose rates ranging from 165 to 250 μGy/day and dose equivalent rates ranging from 340 to 450 μSv/day were measured aboard I.S.S. during the Expedition 2 mission in 2001. Results from the P.D.S. are consistent with those from other passive detectors tested as part of the ground-based I.C.C.H.I.B.A.N. intercomparison of space radiation dosimeters. (authors)

  11. Developing a single-aliquot protocol for measuring equivalent dose in biogenic carbonates

    International Nuclear Information System (INIS)

    Stirling, R.J.; Duller, G.A.T.; Roberts, H.M.

    2012-01-01

    Exploiting biogenic carbonates as thermoluminescence dosimeters requires an understanding of trap kinetics and an appropriate sequence with which to measure equivalent dose. The trap kinetics of two high temperature peaks (peaks II and III) from calcitic snail opercula have been investigated resulting in the calculation of lifetimes of 7.4 × 10 7 and 1.4 × 10 11 years for the two peaks respectively. Two measurement sequences, based upon changes in the application and measurement of a test dose, have been applied to peaks II and III, and though both methods were equally successful in dose recovery and production of a dose response curve some differences were observed. Primarily, the use of method 1 lead to dose dependant sensitivity change implying competition effects occurring during irradiation; method 2 did not experience this phenomenon. As a consequence method 2 was chosen as the most appropriate protocol for single-aliquot dating of this material. When assessing the TL behaviour of the two peaks, peak II performed poorly in dose recovery experiments recovering a dose 60–100% larger than that applied. Disproportionate growth of peak II in response to a beta dose applied prior to measurement, compared to growth following regeneration doses indicated that peak II was not suitable for use in single-aliquot protocols. However, dose recovery results for peak III were all within errors of unity of the given dose, and peak III was therefore chosen as the most appropriate peak for TL dosimetry in these single-aliquot procedures. The lifetime of charge in peak III is sufficient to date over many millions of years, and furthermore using the chosen method 2 the dose response curve has a D 0 of 3,250 ± 163 Gy allowing dating to over 3 million years.

  12. Measurements of the neutron dose equivalent for various radiation qualities, treatment machines and delivery techniques in radiation therapy.

    Science.gov (United States)

    Hälg, R A; Besserer, J; Boschung, M; Mayer, S; Lomax, A J; Schneider, U

    2014-05-21

    In radiation therapy, high energy photon and proton beams cause the production of secondary neutrons. This leads to an unwanted dose contribution, which can be considerable for tissues outside of the target volume regarding the long term health of cancer patients. Due to the high biological effectiveness of neutrons in regards to cancer induction, small neutron doses can be important. This study quantified the neutron doses for different radiation therapy modalities. Most of the reports in the literature used neutron dose measurements free in air or on the surface of phantoms to estimate the amount of neutron dose to the patient. In this study, dose measurements were performed in terms of neutron dose equivalent inside an anthropomorphic phantom. The neutron dose equivalent was determined using track etch detectors as a function of the distance to the isocenter, as well as for radiation sensitive organs. The dose distributions were compared with respect to treatment techniques (3D-conformal, volumetric modulated arc therapy and intensity-modulated radiation therapy for photons; spot scanning and passive scattering for protons), therapy machines (Varian, Elekta and Siemens linear accelerators) and radiation quality (photons and protons). The neutron dose equivalent varied between 0.002 and 3 mSv per treatment gray over all measurements. Only small differences were found when comparing treatment techniques, but substantial differences were observed between the linear accelerator models. The neutron dose equivalent for proton therapy was higher than for photons in general and in particular for double-scattered protons. The overall neutron dose equivalent measured in this study was an order of magnitude lower than the stray dose of a treatment using 6 MV photons, suggesting that the contribution of the secondary neutron dose equivalent to the integral dose of a radiotherapy patient is small.

  13. Equivalent dose measurements on board an Armenian Airline flight and Concord (9-17 km)

    International Nuclear Information System (INIS)

    Akopova, A.B.; Melkonyan, A.A.; Tatikyan, S.Sh.; Capdevielle, J-N.

    2002-01-01

    The results of investigations of the neutron component (E=1-10 MeV) of cosmic radiation on board the 'Armenian Airlines' aircrafts using nuclear photoemulsion are presented. The emulsions were exposed on the flights from Yerevan to Moscow, St.-Petersburg, Beirut, Athens, Frankfurt, Amsterdam, Paris and Sofia, and on Concord supersonic flights from Paris to New York. The dependence of the neutron fluxes, and on absorbed and equivalent doses on the flight parameters were investigated. On the flights of the supersonic Concord, with an altitude of 17 km, the neutron fluxes were essentially higher in comparison to those measured on Armenian airliners. It is interesting to note, that the neutron flux and equivalent dose rate decrease with altitude up to 470 km in space, for example, on board the STS-57. The shape of the differential energy spectrum for fast neutrons is the same on all Armenian airlines flights, but significantly different at 17 km altitude, where the flux in the energy region above 3 MeV is increasing

  14. Equivalent dose measurements on board an Armenian Airline flight and Concord (9-17 km)

    Energy Technology Data Exchange (ETDEWEB)

    Akopova, A.B. E-mail: akopova@lx2.yerphi.am; Melkonyan, A.A.; Tatikyan, S.Sh.; Capdevielle, J-N

    2002-12-01

    The results of investigations of the neutron component (E=1-10 MeV) of cosmic radiation on board the 'Armenian Airlines' aircrafts using nuclear photoemulsion are presented. The emulsions were exposed on the flights from Yerevan to Moscow, St.-Petersburg, Beirut, Athens, Frankfurt, Amsterdam, Paris and Sofia, and on Concord supersonic flights from Paris to New York. The dependence of the neutron fluxes, and on absorbed and equivalent doses on the flight parameters were investigated. On the flights of the supersonic Concord, with an altitude of 17 km, the neutron fluxes were essentially higher in comparison to those measured on Armenian airliners. It is interesting to note, that the neutron flux and equivalent dose rate decrease with altitude up to 470 km in space, for example, on board the STS-57. The shape of the differential energy spectrum for fast neutrons is the same on all Armenian airlines flights, but significantly different at 17 km altitude, where the flux in the energy region above 3 MeV is increasing.

  15. Study of response of radiation monitors for environmental dose equivalent measurements

    International Nuclear Information System (INIS)

    Souza, Macilene N.; Khoury, H.J.

    2005-01-01

    The environmental dose equivalent H * (10), is the magnitude recommended by ICRU 39 for environmental monitoring in fields of radiation of photons. Most of the equipment used for area monitoring, only quantifies the magnitudes exposure or dose not being designed to this new magnitude. In Brazil, particularly, is not yet regulated the use of H * (10). However, with the revision of the standard 3.01 it will necessary the use of monitors that allow the achievement of measures according to H * (10). The transition for using new magnitudes will be a slow process and the contribution that the laboratories of metrology of ionizing radiation in the country can give is, at first, promote and create the habit of using the unit Sievert (Sv) in the calibration of the instruments, and that is the unit recommended for H * (10). In a second step, the tests for determining the response of the instruments for H * (10) should be made and this is the harder step, taking into account the large number of area monitors around the country. These tests will provide information about the limitations of the instrument to the new magnitude, that is, the range where the instrument will have the best performance in quantification of new magnitude. This paper evaluates the performance for H * (10), with the variation of energy and angle of incidence of radiation, of three of the most used monitors in the country

  16. Regional inter-comparison of measurements of personal dose equivalent Hp(10) using photon beams

    International Nuclear Information System (INIS)

    Bero, M.; Zahili, M.; Kharita, M.H.

    2012-11-01

    The overall objective is to verify performance and to improve the Individual Monitoring services (IMS). This can be achieved with the following specific objectives of the intercomparison:1. To assess the capabilities of the dosimetry services to measure the quantity H p (10) in photon (gamma and x-ray) fields. 2. To help the participating Member States in achieving sufficiently accurate dosimetry service and, if necessary, 3. To provide guidelines for improvements and not simply a test of the performance of the existing dosimetric service. Actually a significant improvement has been achieved by the participants in the accuracy of evaluating personal dose equivalent from 15% in the first phase to 5% in the second phase. Some participants used the results of the inter-comparison to verify the calibration and to improve their dosimetric procedures, but from the results it was clear that some participants need to a technical support especially in calibration and using their measuring system in the field of personal monitoring. The conclusion contains advises, solutions, propositions and evaluation for all situations which noticed during the intercomparison. (authors)

  17. Development of neutron dosimeter using CR-39 for measurement of ambient dose equivalent

    International Nuclear Information System (INIS)

    Maki, Daisuke; Shinozaki, Wakako; Ohguchi, Hiroyuki; Yamamoto, Takayoshi; Nakamura, Takayoshi

    2010-01-01

    A CR-39 has good advantages such as cumulative type dosimeter, small fading effect and gamma-ray insensitive. Therefore, we developed the wide energy-range environmental neutron dosimeter using eight CR-39s for area monitoring in this study. This dosimeter is made of octagonal columnar polyethylene block which height is 60 mm and bottom side is 25 mm. The dosimeter contains two types of CR-39s for fast neutron detection and slow neutron detection. Four CR-39s for fast neutron detection are used for detection of recoil protons produced by H (n, p) reactions. Four CR-39s for slow neutron detection are used with boron nitride converter to detect alpha-rays produced by 10 B (n, α) 7 Li reactions. Ambient dose equivalent is obtained by adding the number of etch-pits observed in four CR-39s for fast neutron detection to the number of etch-pits observed in four CR-39s for slow neutron detection with appropriate constants respectively. Dosimeters were irradiated with some energetic neutrons and evaluated results of ambient dose equivalent were compared with results from neutron transport calculations. Energy response of dosimeter shows good agreement with neutron fluence to ambient dose equivalent conversion coefficients. Directional dependence of dosimeter is at the same level as the rem-counter. (author)

  18. Determination of the conversion coefficient for ambient dose equivalent, H(10), from air kerma measurements

    International Nuclear Information System (INIS)

    Gonzalez J, F.; Alvarez R, J. T.

    2015-09-01

    Namely the operational magnitudes can be determined by the product of a conversion coefficient by exposure air kerma or fluence, etc. In particular in Mexico for the first time is determined the conversion coefficient (Cc) for operational magnitude Environmental Dose Equivalent H(10) by thermoluminescence dosimetry (TLD) technique. First 30 TLD-100 dosimeters are calibrated in terms of air kerma, then these dosimeters are irradiated inside a sphere ICRU type of PMMA and with the aid of theory cavity the absorbed dose in PMMA is determined at a depth of 10 mm within the sphere D PMMA (10), subsequently absorbed dose to ICRU tissue is corrected and the dose equivalent H(10) is determined. The Cc is determined as the ratio of H(10)/K a obtaining a value of 1.20 Sv Gy -1 with a u c = 3.66%, this being consistent with the published value in ISO-4037-3 of 1.20 Sv Gy -1 with a u c = 2%. (Author)

  19. Simulation studies on a prototype ionization chamber for measurement of personal dose equivalent, Hp(10)

    International Nuclear Information System (INIS)

    Cardoso, J.; Oliveira, C.; Carvalho, A.F.

    2005-01-01

    Full text: The Metrological Laboratory of lonizing Radiation and Radioactivity (LMRIR) of Nuclear and Technological Institute (ITN) has designed and constructed a prototype ionization chamber for direct measurement of the personal dose equivalent, H p (10), similar to the developed by the Physikalisch-Technische Bundesanstalt (PTB) and now commercialized by PTW. Tests already performed had shown that the behaviour of this chamber is very close to the PTB chamber, namely the energy dependence for the x-ray radiation qualities of the ISO 4037-1 narrow series N-30, N-40, N-60, N-80, N-100 and N-120 and also for gamma radiation of 137 Cs and 60 Co. However, the results obtained also show a high dependence on the energy for some incident radiation angles and a low magnitude of the electrical response of the ionization chamber. In order to try to optimize the performance of the chamber, namely to decrease the energy dependence and to improve the magnitude of the electrical response of the ionization chamber, the LMRIR initiated numerical simulation of this ionization chamber using a Monte-Carlo method for simulation of radiation transport using, in a first step, the MCNPX code. So, simulation studies of some physical parameters are been performed in order to optimize the response of the ionization chamber, namely the diameter of the central electrode of the ionization chamber, the thickness of the front wall of the ionization chamber, among others. Preliminary results show that probably the actual geometry of the ionization chamber is not yet the optimized configuration. The simulation study will carry on in order to find the optimum geometry. (author)

  20. Ambient neutron dose equivalent during proton therapy using wobbling scanning system: Measurements and calculations

    Science.gov (United States)

    Lin, Yung-Chieh; Lee, Chung-Chi; Chao, Tsi-Chian; Tsai, Hui-Yu

    2017-11-01

    Neutron production is a concern in proton therapy, particularly in scattering proton beam delivery systems. Despite this fact, little is known about the effects of secondary neutron exposure around wobbling scattered proton treatment nozzles. The objective of this study was to estimate the neutron dose level resulting from the use of a wobbling scattered proton treatment unit. We applied the Monte Carlo method for predict the ambient neutron dose equivalent, H*(10), per absorbed dose at the treatment isocenter, D, in the proton therapy center of Chang Gung Memorial Hospital, Linkou, Taiwan. For a 190-MeV proton beam, H* (10) / D values typically decreased with the distance from the isocenter, being 1.106 mSv/Gy at the isocenter versus 0.112 mSv/Gy at a distance of 150 cm from the isocenter. The H* (10) / D values generally decreased as the neutron receptors moved away from the isocenter, and increased when the angle from the initial beam axis increased. The ambient neutron dose equivalents were observed to be slightly lower in the direction of multileaf collimator movement. For radiation protection, the central axis of a proton-treated patient is suggested to be at the 0° angle of the beam. If the beam direction at the 90° angle is necessary, the patient axis is suggested to be along with the direction of MLC movement. Our study provides the neutron dose level and neutron energy fluence for the first wobbling proton system at the proton therapy center of Chang Gung Memorial Hospital.

  1. Measurement of dose equivalent distribution on-board commercial jet aircraft

    International Nuclear Information System (INIS)

    Kubancak, J.; Ambrozova, I.; Ploc, O.; Pachnerova Brabcova, K.; Stepan, V.; Uchihori, Y.

    2014-01-01

    The annual effective doses of aircrew members often exceed the limit of 1 mSv for the public due to the increased level of cosmic radiation at the flight altitudes, and thus, it is recommended to monitor them [International Commission on Radiation Protection. 1990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann. ICRP 21(1-3), (1991)]. According to the Monte Carlo simulations [Battistoni, G., Ferrari, A., Pelliccioni, M. and Villari, R. Evaluation of the doses to aircrew members taking into consideration the aircraft structures. Adv. Space Res. 36, 1645-1652 (2005) and Ferrari, A., Pelliccioni, M. and Villari, R. Evaluation of the influence of aircraft shielding on the aircrew exposure through an aircraft mathematical model. Radiat. Prot. Dosim. 108(2), 91-105 (2004)], the ambient dose equivalent rate H*(10) depends on the location in the aircraft. The aim of this article is to experimentally evaluate H*(10) on-board selected types of aircraft. The authors found that H*(10) values are higher in the front and the back of the cabin and lesser in the middle of the cabin. Moreover, total dosimetry characteristics obtained in this way are in a reasonable agreement with other data, in particular with the above-mentioned simulations. (authors)

  2. Dose sculpting with generalized equivalent uniform dose

    International Nuclear Information System (INIS)

    Wu Qiuwen; Djajaputra, David; Liu, Helen H.; Dong Lei; Mohan, Radhe; Wu, Yan

    2005-01-01

    With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this study was to investigate the effectiveness of gEUD optimization to fine tune the dose distributions of IMRT plans. We analyzed the effect of gEUD-based optimization parameters on plan quality. The objective was to determine whether dose distribution to selected structures could be improved using gEUD optimization without adversely altering the doses delivered to other structures, as in sculpting. We hypothesized that by carefully defining gEUD parameters (EUD 0 and n) based on the current dose distributions, the optimization system could be instructed to search for alternative solutions in the neighborhood, and we could maintain the dose distributions for structures already satisfactory and improve dose for structures that need enhancement. We started with an already acceptable IMRT plan optimized with any objective function. The dose distribution was analyzed first. For structures that dose should not be changed, a higher value of n was used and EUD 0 was set slightly higher/lower than the EUD value at the current dose distribution for critical structures/targets. For structures that needed improvement in dose, a higher to medium value of n was used, and EUD 0 was set to the EUD value or slightly lower/higher for the critical structure/target at the current dose distribution. We evaluated this method in one clinical case each of head and neck, lung and prostate cancer. Dose volume histograms, isodose distributions, and relevant tolerance doses for critical structures were used for the assessment. We found that by adjusting gEUD optimization parameters, the dose distribution could be improved with only a few iterations. A larger value of n could lead to

  3. Adoption of new ICRU operational magnitude for the measurement of equivalent doses in Guatemala

    International Nuclear Information System (INIS)

    Guillen, J.A.

    1996-01-01

    This papers compares the results using a dosimetric irradiation in free air under normal incidence and with an IAEA phantom of 30x30x30 in terms of new ICRU magnitudes for the dosimetric systems designed by the National Radiological Protection Board of the United Kingdom with a Kodak Monitoring film type 2. At the same time , this papers presents the characterization requisites and firsts essays as an angular and energy dependence that should be satisfied to establish the regulations for the personal dosimetry service. Finally, it concludes that the dosimetric systems used by the Nuclear Energy general Direction (DGEN) is available for the measurement of the new ICRU Hp and Hs amounts without any additional modifications to the manufacturing of the dosimeter and that users should be trained once again in interpreting body doses with the new philosophy of the ICRP 60

  4. Measurement of conversion coefficients between air Kerma and personal dose equivalent and backscatter factors for diagnostic X-ray beams

    International Nuclear Information System (INIS)

    Rosado, Paulo Henrique Goncalves

    2008-01-01

    Two sets of quantities are import in radiological protection: the protection and operational quantities. Both sets can be related to basic physical quantities such as kerma through conversion coefficients. For diagnostic x-ray beams the conversion coefficients and backscatter factors have not been determined yet, those parameters are need for calibrating dosimeters that will be used to determine the personal dose equivalent or the entrance skin dose. Conversion coefficients between air kerma and personal dose equivalent and backscatter factors were experimentally determined for the diagnostic x-ray qualities RQR and RQA recommended by the International Electrotechnical Commission (IEC). The air kerma in the phantom and the mean energy of the spectrum were measured for such purpose. Harshaw LiF-100H thermoluminescent dosemeters (TLD) were used for measurements after being calibrated against an 180 cm 3 Radcal Corporation ionization chamber traceable to a reference laboratory. A 300 mm x 300 mm x 150 mm polymethylmethacrylate (PMMA) slab phantom was used for deep-dose measurements. Tl dosemeters were placed in the central axis of the x-ray beam at 5, 10, 15, 25 and 35 mm depth in the phantom upstream the beam direction Another required parameter for determining the conversion coefficients from was the mean energy of the x-ray spectrum. The spectroscopy of x-ray beams was done with a CdTe semiconductor detector that was calibrated with 133 Ba, 241 Am and 57 Co radiation sources. Measurements of the x-ray spectra were carried out for all RQR and RQA IEC qualities. Corrections due to the detector intrinsic efficiency, total energy absorption, escape fraction of the characteristic x-rays, Compton effect and attenuation in the detector were done aiming an the accurate determination of the mean energy. Measured x-ray spectra were corrected with the stripping method by using these response functions. The typical combined standard uncertainties of conversion coefficients and

  5. Editorial: New operational dose equivalent quantities

    International Nuclear Information System (INIS)

    Harvey, J.R.

    1985-01-01

    The ICRU Report 39 entitled ''Determination of Dose Equivalents Resulting from External Radiation Sources'' is briefly discussed. Four new operational dose equivalent quantities have been recommended in ICRU 39. The 'ambient dose equivalent' and the 'directional dose equivalent' are applicable to environmental monitoring and the 'individual dose equivalent, penetrating' and the 'individual dose equivalent, superficial' are applicable to individual monitoring. The quantities should meet the needs of day-to-day operational practice, while being acceptable to those concerned with metrological precision, and at the same time be used to give effective control consistent with current perceptions of the risks associated with exposure to ionizing radiations. (U.K.)

  6. MOSFET dosimeter depth-dose measurements in heterogeneous tissue-equivalent phantoms at diagnostic x-ray energies

    International Nuclear Information System (INIS)

    Jones, A.K.; Pazik, F.D.; Hintenlang, D.E.; Bolch, W.E.

    2005-01-01

    The objective of the present study was to explore the use of the TN-1002RD metal-oxide-semiconductor field effect transistor (MOSFET) dosimeter for measuring tissue depth dose at diagnostic photon energies in both homogeneous and heterogeneous tissue-equivalent materials. Three cylindrical phantoms were constructed and utilized as a prelude to more complex measurements within tomographic physical phantoms of pediatric patients. Each cylindrical phantom was constructed as a stack of seven 5-cm-diameter and 1-cm-thick discs of materials radiographically representative of either soft tissue (S), bone (B), or lung tissue (L) at diagnostic photon energies. In addition to a homogeneous phantom of soft tissue (SSSSSSS), two heterogeneous phantoms were constructed: SSBBSSS and SBLLBSS. MOSFET dosimeters were then positioned at the interface of each disc, and the phantoms were then irradiated at 66 kVp and 200 mAs. Measured values of absorbed dose at depth were then compared to predicated values of point tissue dose as determined via Monte Carlo radiation transport modeling. At depths exceeding 2 cm, experimental results matched the computed values of dose with high accuracy regardless of the dosimeter orientation (epoxy bubble facing toward or away from the x-ray beam). Discrepancies were noted, however, between measured and calculated point doses near the surface of the phantom (surface to 2 cm depth) when the dosimeters were oriented with the epoxy bubble facing the x-ray beam. These discrepancies were largely eliminated when the dosimeters were placed with the flat side facing the x-ray beam. It is therefore recommended that the MOSFET dosimeters be oriented with their flat sides facing the beam when they are used at shallow depths or on the surface of either phantoms or patients

  7. Absorbed Dose and Dose Equivalent Calculations for Modeling Effective Dose

    Science.gov (United States)

    Welton, Andrew; Lee, Kerry

    2010-01-01

    While in orbit, Astronauts are exposed to a much higher dose of ionizing radiation than when on the ground. It is important to model how shielding designs on spacecraft reduce radiation effective dose pre-flight, and determine whether or not a danger to humans is presented. However, in order to calculate effective dose, dose equivalent calculations are needed. Dose equivalent takes into account an absorbed dose of radiation and the biological effectiveness of ionizing radiation. This is important in preventing long-term, stochastic radiation effects in humans spending time in space. Monte carlo simulations run with the particle transport code FLUKA, give absorbed and equivalent dose data for relevant shielding. The shielding geometry used in the dose calculations is a layered slab design, consisting of aluminum, polyethylene, and water. Water is used to simulate the soft tissues that compose the human body. The results obtained will provide information on how the shielding performs with many thicknesses of each material in the slab. This allows them to be directly applicable to modern spacecraft shielding geometries.

  8. Calculation methods for determining dose equivalent

    International Nuclear Information System (INIS)

    Endres, G.W.R.; Tanner, J.E.; Scherpelz, R.I.; Hadlock, D.E.

    1988-01-01

    A series of calculations of neutron fluence as a function of energy in an anthropomorphic phantom was performed to develop a system for determining effective dose equivalent for external radiation sources. critical organ dose equivalents are calculated and effective dose equivalents are determined using ICRP-26 methods. Quality factors based on both present definitions and ICRP-40 definitions are used in the analysis. The results of these calculations are presented and discussed

  9. A comparison of quantum limited dose and noise equivalent dose

    Science.gov (United States)

    Job, Isaias D.; Boyce, Sarah J.; Petrillo, Michael J.; Zhou, Kungang

    2016-03-01

    Quantum-limited-dose (QLD) and noise-equivalent-dose (NED) are performance metrics often used interchangeably. Although the metrics are related, they are not equivalent unless the treatment of electronic noise is carefully considered. These metrics are increasingly important to properly characterize the low-dose performance of flat panel detectors (FPDs). A system can be said to be quantum-limited when the Signal-to-noise-ratio (SNR) is proportional to the square-root of x-ray exposure. Recent experiments utilizing three methods to determine the quantum-limited dose range yielded inconsistent results. To investigate the deviation in results, generalized analytical equations are developed to model the image processing and analysis of each method. We test the generalized expression for both radiographic and fluoroscopic detectors. The resulting analysis shows that total noise content of the images processed by each method are inherently different based on their readout scheme. Finally, it will be shown that the NED is equivalent to the instrumentation-noise-equivalent-exposure (INEE) and furthermore that the NED is derived from the quantum-noise-only method of determining QLD. Future investigations will measure quantum-limited performance of radiographic panels with a modified readout scheme to allow for noise improvements similar to measurements performed with fluoroscopic detectors.

  10. Method for measuring dose-equivalent in a neutron flux with an unknown energy spectra and means for carrying out that method

    Science.gov (United States)

    Distenfeld, Carl H.

    1978-01-01

    A method for measuring the dose-equivalent for exposure to an unknown and/or time varing neutron flux which comprises simultaneously exposing a plurality of neutron detecting elements of different types to a neutron flux and combining the measured responses of the various detecting elements by means of a function, whose value is an approximate measure of the dose-equivalent, which is substantially independent of the energy spectra of the flux. Also, a personnel neutron dosimeter, which is useful in carrying out the above method, comprising a plurality of various neutron detecting elements in a single housing suitable for personnel to wear while working in a radiation area.

  11. A MULTI-ELEMENT THICK GAS ELECTRON MULTIPLIER-BASED MICRODOSEMETER FOR MEASUREMENT OF NEUTRONS DOSE-EQUIVALENT: A MONTE CARLO STUDY.

    Science.gov (United States)

    Moslehi, A; Raisali, G

    2017-11-01

    To determine the dose-equivalent of neutrons in an extended energy range, in the present work a multi-element thick gas electron multiplier-based microdosemeter made of PMMA (Perspex) walls of 10 mm in thickness is designed. Each cavity is filled with the propane-based tissue-equivalent (TE) gas simulating 1 µm of tissue. Also, a few weight fractions of 3He are assumed to be added to the TE gas. The dose-equivalents are determined for 11 neutron energies between thermal and 14 MeV using the lineal energy distributions calculated by Geant4 simulation toolkit and also the lineal energy-based quality factors. The results show that by adding 0.04% of 3He to the TE gas in each cavity, an energy-independent dose-equivalent response within 30% uncertainty around a median value of 0.91 in the above energy range is achieved. It is concluded that after its construction, the studied microdosemeter can be used to measure the dose-equivalent of neutrons, favorably. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Dose equivalent rate calculation tool for FBFC

    International Nuclear Information System (INIS)

    Porte, R.; Lengele, C.; Favier, Th.; Duval, A.

    2010-01-01

    The authors present the results obtained by a software designed to compute dose equivalent rate for the critical workstations of the FBFC plant in Romans, France, which will have to deal with an uranium more heavily loaded with U 232 . The uranium spectrum and the ageing time can be varied in order to visualize the evolution of the dose equivalent rate in different locations with respect to the ageing time

  13. Project ''PHANTOM'' - measurement of the absorbed dose, the ''averaged LET'' and the thermal neutron fluence in a tissue equivalent Phantom onboard space station MIR

    International Nuclear Information System (INIS)

    Berger, T.; Hajek, M.; Vana, N.; Schoener, W.; Akatov, Y.; Shurshakov, V.; Arkhangelsky, V.

    2001-01-01

    A water filled phantom with a diameter of 35 cm was developed at the Institute for Biomedical Problems. This tissue equivalent phantom is equipped with 4 channels to deposit dosemeters in different depths. In the framework of the project 'PHANTOM' (phase 1-3) thermoluminescent dosemeters of the commercially available Types TLD - 600 and TLD - 700 were exposed from May 1997 to February 1999 for an overall of 572 days in the different channels (perpendicular and normal to the hull of the spacecraft) of the phantom. The phantom was positioned in the commander cabin, the board engineer cabin and in the module KWANT 2. Besides the measurement of the depth dose distribution, the 'averaged LET' was determined using the HTR - method. The HTR - method utilizes the different LET - efficiencies of the main - and the high temperature glow peaks of LiF dosemeters for the evaluation of the 'averaged LET' in mixed radiation fields. Therefore it is possible to calculate the depth distribution of the biologically relevant dose equivalent. The results show, that despite of the depth decrease of the absorbed dose, the depth dose equivalent is almost constant. This can be explained by the production of secondary particles inside the phantom. The flux of the thermal neutrons was determined using the pair method. Calibration was performed at the research reactor of the Austrian Universities. First results show, that the contribution of thermal neutrons are roughly 10% of the total neutron dose equivalent. (orig.) [de

  14. Minimum detectable dose equivalant of NTA film for fast neutron

    International Nuclear Information System (INIS)

    Ito, Masashi; Kumazawa, Shigeru; Nishi, Tatsuo; Numakunai, Takao

    1982-01-01

    A method has been studied of estimating the minimum detectable dose equivalent of fast neutrons for measurement of recoil proton tracks in NTA film. Poisson distribution was applied in estimation of the minimum detectable number of tracks. Factors such as sensitivity of the film for fast neutrons, energy dependency of the film response, and latent image fading of the tracks were taken into consideration in the estimation. The minimum detectable dose equivalent was affected by fluctuation in the number of tracks due to background radiation and degree of the affection depended on the measured area. The minimum detectable dose equivalent decreased with increasing the measuring area of background radiation even if the measuring area of neutron-irradiated film was small. The relation between the minimum detectable dose equivalent and the measuring area of neutron-irradiated film was obtained considering the effect of latent image fading. (author)

  15. A novel method for patient exit and entrance dose prediction based on water equivalent path length measured with an amorphous silicon electronic portal imaging device

    International Nuclear Information System (INIS)

    Kavuma, Awusi; Glegg, Martin; Metwaly, Mohamed; Currie, Garry; Elliott, Alex

    2010-01-01

    In vivo dosimetry is one of the quality assurance tools used in radiotherapy to monitor the dose delivered to the patient. Electronic portal imaging device (EPID) images for a set of solid water phantoms of varying thicknesses were acquired and the data fitted onto a quadratic equation, which relates the reduction in photon beam intensity to the attenuation coefficient and material thickness at a reference condition. The quadratic model is used to convert the measured grey scale value into water equivalent path length (EPL) at each pixel for any material imaged by the detector. For any other non-reference conditions, scatter, field size and MU variation effects on the image were corrected by relative measurements using an ionization chamber and an EPID. The 2D EPL is linked to the percentage exit dose table, for different thicknesses and field sizes, thereby converting the plane pixel values at each point into a 2D dose map. The off-axis ratio is corrected using envelope and boundary profiles generated from the treatment planning system (TPS). The method requires field size, monitor unit and source-to-surface distance (SSD) as clinical input parameters to predict the exit dose, which is then used to determine the entrance dose. The measured pixel dose maps were compared with calculated doses from TPS for both entrance and exit depth of phantom. The gamma index at 3% dose difference (DD) and 3 mm distance to agreement (DTA) resulted in an average of 97% passing for the square fields of 5, 10, 15 and 20 cm. The exit dose EPID dose distributions predicted by the algorithm were in better agreement with TPS-calculated doses than phantom entrance dose distributions.

  16. Effective dose equivalents from external radiation due to Chernobyl accident

    International Nuclear Information System (INIS)

    Erkin, V.G.; Debedev, O.V.; Balonov, M.I.; Parkhomenko, V.I.

    1992-01-01

    Summarized data on measurements of individual dose of external γ-sources in 1987-1990 of population of western areas of Bryansk region were presented. Type of distribution of effective dose equivalent, its significance for various professional and social groups of population depending on the type of the house was discussed. Dependences connecting surface soil activity in the populated locality with average dose of external radiation sources were presented. Tendency of dose variation in 1987-1990 was shown

  17. Measurement of the ambient gamma dose equivalent and kerma from the small 252Cf source at 1 meter and the small 60Co source at 2 meters

    Energy Technology Data Exchange (ETDEWEB)

    Carl, W. F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-07-30

    NASA Langley Research Center requested a measurement and determination of the ambient gamma dose equivalent rate and kerma at 100 cm from the 252Cf source and determination of the ambient gamma dose equivalent rate and kerma at 200 cm from the 60Co source for the Radiation Budget Instrument Experiment (Rad-X). An Exradin A6 ion chamber with Shonka air-equivalent plastic walls in combination with a Supermax electrometer were used to measure the exposure rate and free-in-air kerma rate of the two sources at the requested distances. The measured gamma exposure, kerma, and dose equivalent rates are tabulated.

  18. Measurement of extrapolation curves for the secondary pattern of beta radiation Nr. 86 calibrated in rapidity of absorbed dose for tissue equivalent by the Physikalisch Technische Bundesanstalt

    International Nuclear Information System (INIS)

    Alvarez R, J.T.

    1988-10-01

    The following report has as objective to present the obtained results of measuring - with a camera of extrapolation of variable electrodes (CE) - the dose speed absorbed in equivalent fabric given by the group of sources of the secondary pattern of radiation Beta Nr. 86, (PSB), and to compare this results with those presented by the calibration certificates that accompany the PSB extended by the primary laboratory Physikalisch Technische Bundesanstalt, (PTB), of the R.F.A. as well as the uncertainties associated to the measure process. (Author)

  19. Verification of an effective dose equivalent model for neutrons

    International Nuclear Information System (INIS)

    Tanner, J.E.; Piper, R.K.; Leonowich, J.A.; Faust, L.G.

    1992-01-01

    Since the effective dose equivalent, based on the weighted sum of organ dose equivalents, is not a directly measurable quantity, it must be estimated with the assistance of computer modelling techniques and a knowledge of the incident radiation field. Although extreme accuracy is not necessary for radiation protection purposes, a few well chosen measurements are required to confirm the theoretical models. Neutron doses and dose equivalents were measured in a RANDO phantom at specific locations using thermoluminescence dosemeters, etched track dosemeters, and a 1.27 cm (1/2 in) tissue-equivalent proportional counter. The phantom was exposed to a bare and a D 2 O-moderated 252 Cf neutron source at the Pacific Northwest Laboratory's Low Scatter Facility. The Monte Carlo code MCNP with the MIRD-V mathematical phantom was used to model the human body and to calculate the organ doses and dose equivalents. The experimental methods are described and the results of the measurements are compared with the calculations. (author)

  20. Verification of an effective dose equivalent model for neutrons

    International Nuclear Information System (INIS)

    Tanner, J.E.; Piper, R.K.; Leonowich, J.A.; Faust, L.G.

    1991-10-01

    Since the effective dose equivalent, based on the weighted sum of organ dose equivalents, is not a directly measurable quantity, it must be estimated with the assistance of computer modeling techniques and a knowledge of the radiation field. Although extreme accuracy is not necessary for radiation protection purposes, a few well-chosen measurements are required to confirm the theoretical models. Neutron measurements were performed in a RANDO phantom using thermoluminescent dosemeters, track etch dosemeters, and a 1/2-in. (1.27-cm) tissue equivalent proportional counter in order to estimate neutron doses and dose equivalents within the phantom at specific locations. The phantom was exposed to bare and D 2 O-moderated 252 Cf neutrons at the Pacific Northwest Laboratory's Low Scatter Facility. The Monte Carlo code MCNP with the MIRD-V mathematical phantom was used to model the human body and calculate organ doses and dose equivalents. The experimental methods are described and the results of the measurements are compared to the calculations. 8 refs., 3 figs., 3 tabs

  1. Image processing techniques revealing the relationship between the field-measured ambient gamma dose equivalent rate and geological conditions at a granitic area, Velence Mountains, Hungary

    Science.gov (United States)

    Beltran Torres, Silvana; Petrik, Attila; Zsuzsanna Szabó, Katalin; Jordan, Gyozo; Szabó, Csaba

    2017-04-01

    In order to estimate the annual dose that the public receive from natural radioactivity, the identification of the potential risk areas is required which, in turn, necessitates understanding the relationship between the spatial distribution of natural radioactivity and the geogenic risk factors (e.g., rock types, dykes, faults, soil conditions, etc.). A detailed spatial analysis of ambient gamma dose equivalent rate was performed in the western side of Velence Mountains, the largest outcropped granitic area in Hungary. In order to assess the role of local geology in the spatial distribution of ambient gamma dose rates, field measurements were carried out at ground level at 300 sites along a 250 m x 250 m regular grid in a total surface of 14.7 km2. Digital image processing methods were applied to identify anomalies, heterogeneities and spatial patterns in the measured gamma dose rates, including local maxima and minima determination, digital cross sections, gradient magnitude and gradient direction, second derivative profile curvature, local variability, lineament density, 2D autocorrelation and directional variogram analyses. Statistical inference showed that different gamma dose rate levels are associated with the rock types (i.e., Carboniferous granite, Pleistocene colluvial, proluvial, deluvial sediments and talus, and Pannonian sand and pebble), with the highest level on the Carboniferous granite including outlying values. Moreover, digital image processing revealed that linear gamma dose rate spatial features are parallel to the SW-NE dyke system and possibly to the NW-SE main fractures. The results of this study underline the importance of understanding the role of geogenic risk factors influencing the ambient gamma dose rate received by public. The study also demonstrates the power of the image processing techniques for the identification of spatial pattern in field-measured geogenic radiation.

  2. On the calibration of photon dosemeters in the equivalent dose units

    International Nuclear Information System (INIS)

    Bregadze, Yu.I.; Isaev, B.M.; Maslyaev, P.F.

    1980-01-01

    General aspects of transition from exposure dose of photo radiation to equivalent one are considered. By determination the equivalent dose is a function of point location in an irradiated object, that is why it is necessary to know equivalent dose distribution in the human body for uniform description of the risk degree. The international electrotechnical comission recommends to measure equivalent doses at 7 and 800 mg/cm 2 depths in a tissue-equivalent ball with 30 cm diameter, calling them skin equivalent dose and depth equivalent dose, respectively, and to compare them with the permissible 500 mZ and 50 mZ a year, respectively. Practical transition to using equivalent dose for evaluation of radiation danger of being in photon radiation field of low energy should include measures on regraduating already produced dose meters, graduating the dose meters under production and developing the system of their metrologic supply [ru

  3. Measurements of LET distribution and dose equivalent onboard the Space Shuttle IML-2 (STS-65) and S/MM#4 (STS-79)

    Science.gov (United States)

    Hayashi, T.; Doke, T.; Kikuchi, J.; Sakaguchi, T.; Takeuchi, R.; Takashima, T.; Kobayashi, M.; Terasawa, K.; Takahashi, K.; Watanabe, A.; hide

    1997-01-01

    Space radiation dosimetry measurements have been made onboard the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2: 28.5 degrees x 300 km: 14.68 days) and the STS-79 in the 4th Shuttle MIR mission (S/MM#4: 51.6 degrees x 300-400km: 10.2 days). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD-I for IML-2 and RRMD-II with improved triggering system for S/MM#4)" utilizing silicon semi-conductor detectors and the other detectors are conventional passive detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. The main contribution to dose equivalent for particles with LET > 5.0 keV/micrometer (IML-2) and LET > 3.5 keV/micrometer (S/MM#4) is seen to be due to galactic cosmic rays (GCRs) and the contribution of the South Atlantic Anomaly (SAA) is less than 5% (IML-2: 28.5 degrees x 300 km) and 15% (S/MM#4: 51.6 degrees x 400 km) in the above RRMD LET detection conditions. For the whole LET range (> 0.2 kev/micrometer) obtained by TLDs and CR-39 in these two typical orbits (a small inclination x low altitude and a large inclination x high altitude), absorbed dose rates range from 94 to 114 microGy/day, dose equivalent rates from 186 to 207 microSv/day and average quality factors from 1.82 to 2.00 depending on the locations and directions of detectors inside the Spacelab at the highly protected IML-2 orbit (28.5 degrees x 300 km), and also, absorbed dose rates range from 290 to 367 microGy/day, dose equivalent rates from 582 to 651 microSv/day and average quality factors from 1.78 to 2.01 depending on the dosimeter packages around the RRMD-II "Detector Unit" at the S/MM#4 orbit (5l.6 degrees x 400km). In general, it is seen that absorbed doses depend on the orbit altitude (SAA trapped particles contribution dominant) and dose equivalents on the orbit inclination (GCR contribution dominant). The LET

  4. Calculation of exit dose for conformal and dynamically‐wedged fields, based on water‐equivalent path length measured with an amorphous silicon electronic portal imaging device

    Science.gov (United States)

    Glegg, Martin; Metwaly, Mohamed; Currie, Garry; Elliott, Alex

    2011-01-01

    In this study, we use the quadratic calibration method (QCM), in which an EPID image is converted into a matrix of equivalent path lengths (EPLs) and, therefore, exit doses, so as to model doses in conformal and enhanced dynamic wedge (EDW) fields. The QCM involves acquiring series of EPID images at a reference field size for different thicknesses of homogeneous solid water blocks. From these, a set of coefficients is established that is used to compute the EPL of any other irradiated material. To determine the EPL, the irradiated area must be known in order to establish the appropriate scatter correction. A method was devised for the automatic calculation of areas from the EPID image that facilitated the calculation of EPL for any field and exit dose. For EDW fields, the fitting coefficients were modified by utilizing the linac manufacturer's golden segmented treatment tables (GSTT) methodology and MU fraction model. The nonlinear response of the EPL with lower monitor units (MUs) was investigated and slight modification of the algorithm performed to account for this. The method permits 2D dose distributions at the exit of phantom or patient to be generated by relating the EPL with an appropriate depth dose table. The results indicate that the inclusion of MU correction improved the EPL determination. The irradiated field areas can be accurately determined from EPID images to within ± 1% uncertainty. Cross‐plane profiles and 2D dose distributions of EPID predicted doses were compared with those calculated with the Eclipse treatment planning system (TPS) and those measured directly with MapCHECK 2 device. Comparison of the 2D EPID dose maps to those from TPS and MapCHECK shows that more than 90% of all points passed the gamma index acceptance criteria of 3% dose difference and 3 mm distance to agreement (DTA), for both conformal and EDW study cases. We conclude that the EPID QCM is an accurate and convenient method for in vivo dosimetry and may, therefore

  5. Development of a neutron personal dose equivalent detector

    International Nuclear Information System (INIS)

    Tsujimura, N.; Yoshida, T.; Takada, C.; Momose, T.; Nunomiya, T.; Aoyama, K.

    2007-01-01

    A new neutron-measuring instrument that is intended to measure a neutron personal dose equivalent, H p (10) was developed. This instrument is composed of two parts: (1) a conventional moderator-based neutron dose equivalent meter and (2) a neutron shield made of borated polyethylene, which covers a backward hemisphere to adjust the angular dependence. The whole design was determined on the basis of MCNP calculations so as to have response characteristics that would generally match both the energy and angular dependencies of H p (10). This new instrument will be a great help in assessing the reference values of neutron H p (10) during field testing of personal neutron dosemeters in workplaces and also in interpreting their readings. (authors)

  6. Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Nishizawa, Kanae; Kumamoto, Yoshikazu; Iwai, Kazuo; Mase, Naomichi.

    1993-01-01

    Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously calculated using a chord length technique and with data from ICRP publications. The annual collective effective dose equivalent were estimated to be about 21.94 person·Sv for medical workers, 7.73 person·Sv for industrial workers, 0.75 person·Sv for research and educational workers, 2.48 person·Sv for atomic energy industry and 84.4 person ·Sv for workers in nuclear power station. The population doses were calculated to be about 1.07 Sv for genetically significant dose, 0.89 Sv for leukemia significant dose and 0.42 Sv for malignant significant dose. The population risks were estimated using these population doses. (author)

  7. Determination of dose equivalent and risk in thorium cycle

    International Nuclear Information System (INIS)

    Ney, C.L.V.N.

    1988-01-01

    In these report are presented the calculations of dose equivalent and risk, utilizing the dosimetric model described in publication 30 of the International Comission on Radiological Protection. This information was obtained by the workers of the thorium cycle, employed at the Praia and Santo Amaro Facilities, by assessing the quantity and concentration of thorium in the air. The samples and the number of measurements were established through design of experiments techniques, and the results were evaluated with the aid of variance analysis. The estimater of dose equivalent for internal and external radiation exposure and risk associated were compared with the maximum recommended limits. The results indicate the existence of operation areas whose values were above those limits, requiring so an improvement in the procedures and services in order to meet the requirements of the radiological protetion. (author) [pt

  8. Estimation of activity of administered18F-fluorodeoxyglucose by measurement of the dose equivalent rate on the right temporal region of the head.

    Science.gov (United States)

    Sakaguchi, Kenta; Hosono, Makoto; Imamura, Tomomi; Takahara, Naomi; Hayashi, Misa; Yakushiji, Yuko; Ishii, Kazunari; Uto, Tatsuro; Murakami, Takamichi

    2016-12-01

    Positron emission tomography (PET) with 18 F-fluorodeoxyglucose (FDG) is now a routine procedure for the management of cancer patients. Intravenous administration of FDG is sometimes halted due to troubles. In such cases, estimations of the FDG dosage injected prior to halting administration may be helpful. We have established a method of estimating the activity of FDG to patients on the basis of the dose equivalent rate on the surface of the right temporal region of the head. The correlation of actual administered dosage with independent variables, such as the dose equivalent rate on the right temporal region of the head, age, sex, and body weight, was analyzed using multiple regression analysis to obtain linear, quadratic, and cubic regression equations. When entering independent variables, the cubic regression equation could be used to estimate an administered dosage with an accuracy of ±10 % for 62 % of all patients and ±20 % for 90 % of all patients. We conclude that this method is useful for estimating the administered dosage from the dose equivalent rate on the temporal region of the head.

  9. Calculation of committed dose equivalent from intake of tritiated water

    International Nuclear Information System (INIS)

    Law, D.V.

    1978-08-01

    A new computerized method of calculating the committed dose equivalent from the intake of tritiated water at Harwell is described in this report. The computer program has been designed to deal with a variety of intake patterns and urine sampling schemes, as well as to produce committed dose equivalents corresponding to any periods for which individual monitoring for external radiation is undertaken. Details of retrospective doses are added semi-automatically to the Radiation Dose Records and committed dose equivalents are retained on a separate file. (author)

  10. BH3105 type neutron dose equivalent meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Enshan; Yang Jianfeng; Zhang Hong; Huang Jiling

    1995-10-01

    It is noted that to design a neutron dose meter of high sensitivity is almost impossible in the frame of traditional designing principle--'absorption net principle'. Based on a newly proposed principle of obtaining neutron dose equi-biological effect adjustment--' absorption stick principle', a brand-new neutron dose-equivalent meter with high neutron sensitivity BH3105 has been developed. Its sensitivity reaches 10 cps/(μSv·h -1 ), which is 18∼40 times higher than one of foreign products of the same kind and is 10 4 times higher than that of domestic FJ342 neutron rem-meter. BH3105 has a measurement range from 0.1μSv/h to 1 Sv/h which is 1 or 2 orders wider than that of the other's. It has the advanced properties of gamma-resistance, energy response, orientation, etc. (6 tabs., 5 figs.)

  11. Annual average equivalent dose of workers form health area

    International Nuclear Information System (INIS)

    Daltro, T.F.L.; Campos, L.L.

    1992-01-01

    The data of personnel monitoring during 1985 and 1991 of personnel that work in health area were studied, obtaining a general overview of the value change of annual average equivalent dose. Two different aspects were presented: the analysis of annual average equivalent dose in the different sectors of a hospital and the comparison of these doses in the same sectors in different hospitals. (C.G.C.)

  12. Committed dose equivalent in the practice of radiological protection

    International Nuclear Information System (INIS)

    Nenot, J.C.; Piechowski, J.

    1985-01-01

    In the case of internal exposure, the dose is not received at the moment of exposure, as happens with external exposure, since the incorporated radionuclide irradiates the various organs and tissues during the time it is present in the body. By definition, the committed dose equivalent corresponds to the received dose integrated over 50 years from the date of intake. In order to calculate it, one has to know the intake activity and the value of the committed dose equivalent per unit of intake activity. The uncertainties of the first parameter are such that the committed dose equivalent can only be regarded as an order of magnitude and not as a very accurate quantity. The use of it is justified, however, for, like the dose equivalent for external exposure, it expresses the risk of stochastic effects for the individual concerned since these effects, should they appear, would do so only after a latent period which is generally longer than the dose integration time. Moreover, the use of the committed dose equivalent offers certain advantages for dosimetric management, especially when it is simplified. A practical problem which may arise is that the annual dose limit is apparently exceeded by virtue of the fact that one is taking account, in the first year, of doses which will actually be received only in the following years. These problems are rare enough in practice to be dealt with individually in each case. (author)

  13. Dose equivalent response of personal neutron dosemeters as a function of angle

    International Nuclear Information System (INIS)

    Tanner, J.E.; McDonald, J.C.; Stewart, R.D.; Wernli, C.

    1997-01-01

    The measured and calculated dose equivalent response as a function of angle has been examined for an albedo-type thermoluminescence dosemeter (TLD) that was exposed to unmoderated and D 2 O-moderated 252 Cf neutron sources while mounted on a 40 x 40 15 cm 3 polymethylmethacrylate phantom. The dosemeter used in this study is similar to many neutron personal dosemeters currently in use. The detailed construction of the dosemeter was modelled, and the dose equivalent response was calculated, using the MCNP code. Good agreement was found between the measured and calculated values of the relative dose equivalent angular response for the TLD albedo dosemeter. The relative dose equivalent angular response was also compared with the values of directional and personal dose equivalent as a function of angle published by Siebert and Schuhmacher. (author)

  14. Variation of indoor radon concentration and ambient dose equivalent rate in different outdoor and indoor environments

    International Nuclear Information System (INIS)

    Stojanovska, Zdenka; Janevik, Emilija; Taleski, Vaso; Boev, Blazo; Zunic, Zora S.; Ivanova, Kremena; Tsenova, Martina; Ristova, Mimoza; Ajka, Sorsa; Bossew, Peter

    2016-01-01

    Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m 3 for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported. (orig.)

  15. Variation of indoor radon concentration and ambient dose equivalent rate in different outdoor and indoor environments

    Energy Technology Data Exchange (ETDEWEB)

    Stojanovska, Zdenka; Janevik, Emilija; Taleski, Vaso [Goce Delcev University, Faculty of Medical Sciences, Stip (Macedonia, The Former Yugoslav Republic of); Boev, Blazo [Goce Delcev University, Faculty of Natural and Technical Sciences, Stip (Macedonia, The Former Yugoslav Republic of); Zunic, Zora S. [University of Belgrade, Institute of Nuclear Sciences ' ' Vinca' ' , Belgrade (Serbia); Ivanova, Kremena; Tsenova, Martina [National Center of Radiobiology and Radiation Protection, Sofia (Bulgaria); Ristova, Mimoza [University in Ss. Cyril and Methodius, Faculty of Natural Sciences and Mathematic, Institute of Physics, Skopje (Macedonia, The Former Yugoslav Republic of); Ajka, Sorsa [Croatian Geological Survey, Zagreb (Croatia); Bossew, Peter [German Federal Office for Radiation Protection, Berlin (Germany)

    2016-05-15

    Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m{sup 3} for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported. (orig.)

  16. Determination of skin dose reduction by lead equivalent gloves

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Abd Aziz Mhd Ramli

    2006-01-01

    Radiation protective gloves are always used in medical facilities to protect radiation workers from unnecessary radiation exposure. A study on radiation protection gloves which are produced by local company had been performed by the Medical Physics Group, MINT. The gloves were made of lead equivalent material, as the attenuating element. The gloves were evaluated in term of the percentage of skin dose reduction by using a newly developed procedure and facilities in MINT. Attenuation measurements of the gloves had been carried out using direct beams and scattered radiations of different qualities. TLD rings were fitted on finger phantom; and water phantom were used in the measurement. The result were obtained and analysed based on data supplied by manufacturer. (Author)

  17. Evaluation of effective dose equivalent from environmental gamma rays

    International Nuclear Information System (INIS)

    Saito, K.; Tsutsumi, M.; Moriuchi, S.; Petoussi, N.; Zankl, M.; Veit, R.; Jacob, P.; Drexler, G.

    1991-01-01

    Organ doses and effective dose equivalents for environmental gamma rays were calculated using human phantoms and Monte Carlo methods accounting rigorously the environmental gamma ray fields. It was suggested that body weight is the dominant factor to determine organ doses. The weight function expressing organ doses was introduced. Using this function, the variation in organ doses due to several physical factors were investigated. A detector having gamma-ray response similar to that of human bodies has been developed using a NaI(Tl) scintillator. (author)

  18. INTERCOMPARISON ON THE MEASUREMENT OF THE QUANTITY PERSONAL DOSE EQUIVALENT HP(10) IN PHOTON FIELDS. LINEARITY DEPENDENCE, LOWER LIMIT OF DETECTION AND UNCERTAINTY IN MEASUREMENT OF DOSIMETRY SYSTEMS OF INDIVIDUAL MONITORING SERVICES IN GABON AND GHANA.

    Science.gov (United States)

    Ondo Meye, P; Schandorf, C; Amoako, J K; Manteaw, P O; Amoatey, E A; Adjei, D N

    2017-12-01

    An inter-comparison study was conducted to assess the capability of dosimetry systems of individual monitoring services (IMSs) in Gabon and Ghana to measure personal dose equivalent Hp(10) in photon fields. The performance indicators assessed were the lower limit of detection, linearity and uncertainty in measurement. Monthly and quarterly recording levels were proposed with corresponding values of 0.08 and 0.025 mSv, and 0.05 and 0.15 mSv for the TLD and OSL systems, respectively. The linearity dependence of the dosimetry systems was performed following the requirement given in the Standard IEC 62387 of the International Electrotechnical Commission (IEC). The results obtained for the two systems were satisfactory. The procedure followed for the uncertainty assessment is the one given in the IEC technical report TR62461. The maximum relative overall uncertainties, in absolute value, expressed in terms of Hp(10), for the TL dosimetry system Harshaw 6600, are 44. 35% for true doses below 0.40 mSv and 36.33% for true doses ≥0.40 mSv. For the OSL dosimetry system microStar, the maximum relative overall uncertainties, in absolute value, are 52.17% for true doses below 0.40 mSv and 37.43% for true doses ≥0.40 mSv. These results are in good agreement with the requirements for accuracy of the International Commission on Radiological protection. When expressing the uncertainties in terms of response, comparison with the IAEA requirements for overall accuracy showed that the uncertainty results were also acceptable. The values of Hp(10) directly measured by the two dosimetry systems showed a significant underestimation for the Harshaw 6600 system, and a slight overestimation for the microStar system. After correction for linearity of the measured doses, the two dosimetry systems gave better and comparable results. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. The radiobiology of boron neutron capture therapy: Are ''photon-equivalent'' doses really photon-equivalent?

    International Nuclear Information System (INIS)

    Coderre, J.A.; Diaz, A.Z.; Ma, R.

    2001-01-01

    Boron neutron capture therapy (BNCT) produces a mixture of radiation dose components. The high-linear energy transfer (LET) particles are more damaging in tissue than equal doses of low-LET radiation. Each of the high-LET components can multiplied by an experimentally determined factor to adjust for the increased biological effectiveness and the resulting sum expressed in photon-equivalent units (Gy-Eq). BNCT doses in photon-equivalent units are based on a number of assumptions. It may be possible to test the validity of these assumptions and the accuracy of the calculated BNCT doses by 1) comparing the effects of BNCT in other animal or biological models where the effects of photon radiation are known, or 2) if there are endpoints reached in the BNCT dose escalation clinical trials that can be related to the known response to photons of the tissue in question. The calculated Gy-Eq BNCT doses delivered to dogs and to humans with BPA and the epithermal neutron beam of the Brookhaven Medical Research Reactor were compared to expected responses to photon irradiation. The data indicate that Gy-Eq doses in brain may be underestimated. Doses to skin are consistent with the expected response to photons. Gy-Eq doses to tumor are significantly overestimated. A model system of cells in culture irradiated at various depths in a lucite phantom using the epithermal beam is under development. Preliminary data indicate that this approach can be used to detect differences in the relative biological effectiveness of the beam. The rat 9L gliosarcoma cell survival data was converted to photon-equivalent doses using the same factors assumed in the clinical studies. The results superimposed on the survival curve derived from irradiation with Cs-137 photons indicating the potential utility of this model system. (author)

  20. Measurements of U and Ra Activities in Drinking Water Samples and of Rn in Dwellings in Morocco. Calculation of Equivalent Effective Doses

    International Nuclear Information System (INIS)

    Choukri, A.; Hakam, O.K.

    2013-01-01

    Activities of uranium and radium isotopes were measured in some drinking water samples collected from wells, springs and tap water samples. The obtained results show that the 238 U activity, is relatively higher in wells than in springs and 226 Ra activity is more higher in hot springs. The results are similar to those published for other non polluting regions of the world and don't present any risk for public health in Morocco. In parallel measurements of indoor radon showed that the calculated effective dose for dwellings are comparable to those obtained in other regions in the word. The risks related to these activities could be avoided by simple precautions such the continuous ventilation.

  1. Possibility and necessity measures and integral equivalence

    Czech Academy of Sciences Publication Activity Database

    Chen, T.; Mesiar, Radko; Li, J.; Stupňanová, A.

    2017-01-01

    Roč. 86, č. 1 (2017), s. 62-72 ISSN 0888-613X Institutional support: RVO:67985556 Keywords : Integral equivalence * Necessity measure * Possibility measure * Survival function * Universal integral Subject RIV: BA - General Mathematics OBOR OECD: Statistics and probability Impact factor: 2.845, year: 2016 http://library.utia.cas.cz/separaty/2017/E/mesiar-0477092.pdf

  2. Equivalent dose determination using a quartz isothermal TL signal

    DEFF Research Database (Denmark)

    Vandenberghe, D.A.G.; Jain, Mayank; Murray, A.S.

    2009-01-01

    signal can be fully reset by sunlight, and grows with dose over at least the same range as the OSL signal. A single-aliquot regenerative-dose (SAR) protocol can be used with this ITL signal. Dose recovery experiments confirm the suitability of the measurement protocol; the De values are in acceptable...... agreement with the expected burial dose in samples from a variety of depositional environments and ages. Our results suggest that measurement of the ITL signal at 270 °C enables the quartz 325 °C TL peak to be used for accurate dose measurements on a single aliquot. The signal allows dating over at least...

  3. Procedures for Determining the Equivalence of Measures.

    Science.gov (United States)

    Dunivant, Noel

    Eight different methods are reviewed for determining whether two or more tests are equivalent measures. These methods vary in restrictiveness from the Wilks-Votaw test of compound symmetry (which requires that all means, variances, and covariances are equal), to Joreskog's theory of congeneric tests (which requires only that the tests are measures…

  4. Quartz red TL SAR equivalent dose overestimation for Chinese loess

    DEFF Research Database (Denmark)

    Lai, Z.P.; Murray, A.S.; Bailey, R.M.

    2006-01-01

    For the red TL of quartz extracted from Chinese loess, the single-aliquot regenerative-dose (SAR) procedure overestimates the known laboratory doses in dose recovery test. The overestimation is the result of the first heating during the measurement of natural TL signal causing a sensitivity...

  5. Dose equivalent distribution during occupational exposure in oncology

    International Nuclear Information System (INIS)

    Marco H, J.

    1996-01-01

    In this work are presented the results of the radiological surveillance of occupationally exposed workers at the National Institute of Oncology and Radiology during 26 years. The incidence of the equivalent dose in the personal working with radiant sources and radioactive substances in areas of x rays diagnostic, teletherapy, brachytherapy, nuclear medicine and biomedical research was showed. The employed dosimetric system makes use of ORWO RD3/RD4 monitoring film with copper and lead filters inside a plastic cassette manufactured in Cuba. The experimental method is supported by the optical densitometric analysis of films together with a set of standard film calibrated in standard X and gamma photon beams by means of a secondary standard dosimeter, type NPL. Statistics show that except those workings with radium-226, manual brachytherapy or Mo-99/Tc-99 generator elution, the equivalent dose distribution in our workers has been kept in regions well down the annual permissible limit. (authors). 6 refs., 3 tabs

  6. Evaluation of personal dose equivalent using optically stimulated luminescent dosemeters in Marumori after the Fukushima nuclear accident

    International Nuclear Information System (INIS)

    Yoshida-Ohuchi, H.; Hirasawa, N.; Kobayashi, I.; Yoshizawa, T.

    2013-01-01

    The personal dose equivalent for 36 Marumori residents living in wooden houses was evaluated using optically stimulated luminescent dosemeters after the Fukushima nuclear accident. The cumulative doses to residents over 200 d from 1 September 2011 ranged from 536 to 1490 μSv. In each resident's house, the indoor and outdoor ambient dose equivalents were measured with an NaI scintillation survey meter. A linear relationship with a slope of 0.5 was found between them; however, the ratio of the indoor to the outdoor ambient dose equivalent varied from 0.36 to 1.0. A better linear relationship was observed between the personal dose equivalent and the indoor ambient dose equivalent compared with that between the personal dose equivalent and the outdoor ambient dose equivalent. These results indicate that the individual exposure dose depends on the indoor ambient dose equivalent rather than the outdoor ambient dose equivalent. These results should be very helpful in obtaining the countermeasures to reduce residents' exposure dose. (authors)

  7. Neutrons in active proton therapy. Parameterization of dose and dose equivalent

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Uwe; Haelg, Roger A. [Univ. of Zurich (Switzerland). Dept. of Physics; Radiotherapy Hirslanden AG, Aarau (Switzerland); Lomax, Tony [Paul Scherrer Institute, Villigen (Switzerland). Center for Proton Therapy

    2017-08-01

    One of the essential elements of an epidemiological study to decide if proton therapy may be associated with increased or decreased subsequent malignancies compared to photon therapy is an ability to estimate all doses to non-target tissues, including neutron dose. This work therefore aims to predict for patients using proton pencil beam scanning the spatially localized neutron doses and dose equivalents. The proton pencil beam of Gantry 1 at the Paul Scherrer Institute (PSI) was Monte Carlo simulated using GEANT. Based on the simulated neutron dose and neutron spectra an analytical mechanistic dose model was developed. The pencil beam algorithm used for treatment planning at PSI has been extended using the developed model in order to calculate the neutron component of the delivered dose distribution for each treated patient. The neutron dose was estimated for two patient example cases. The analytical neutron dose model represents the three-dimensional Monte Carlo simulated dose distribution up to 85 cm from the proton pencil beam with a satisfying precision. The root mean square error between Monte Carlo simulation and model is largest for 138 MeV protons and is 19% and 20% for dose and dose equivalent, respectively. The model was successfully integrated into the PSI treatment planning system. In average the neutron dose is increased by 10% or 65% when using 160 MeV or 177 MeV instead of 138 MeV. For the neutron dose equivalent the increase is 8% and 57%. The presented neutron dose calculations allow for estimates of dose that can be used in subsequent epidemiological studies or, should the need arise, to estimate the neutron dose at any point where a subsequent secondary tumour may occur. It was found that the neutron dose to the patient is heavily increased with proton energy.

  8. Radiation protection instrumentation ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation

    International Nuclear Information System (INIS)

    2004-01-01

    This international standard applies to dose equivalent (rate) meters and/or monitors for the measurement of ambient dose equivalent (rate) and/or directional dose equivalent (rate) from external beta, X and gamma radiation, as recommended in ICRU report 47. Note 1: if both quantities, ambient dose equivalent and directional dose equivalent are meant, the term dose equivalent may be used as an abbreviation. It applies directly to dose equivalent (rate) meters intended for the determination of the dose equivalent or dose equivalent rate from external beta and/or X and gamma radiation of energies up to 10 MeV for radiation protection purposes. In this document, the expression 'dose equivalent (rate)' is used when the provisions apply to both measurement of dose equivalent and the measurement of dose equivalent rate. Note 2: It does not apply to medical radiology which is within the scope of technical committee 62, where the conditions of radiation exposure may be extremely inhomogeneous, but precisely known. Note 3 It does not apply directly to instruments intended to be worn by an individual for the purpose of estimating the radiation dose received by that individual. The object of this standard is to specify the design requirements and the performance characteristics of dose equivalent ( rate) meters intended for the determination of ambient dose equivalent ( rate) and directional dose equivalent (rate) as defined in ICRU Report 47. Accordingly, this standard specifies: a) general characteristics, the functions and performance characteristics of dose equivalent (rate) meters; b) the methods of test to be used to determine compliance with requirements of this standard. (ICRU Report 47: 1992, Measurements of dose equivalents from external photons and electron radiations, International Commission on Radiation Units and Measurements, 7910 Woodmont Avenue, Bethesda, Maryland 20814-3095, U.S.A.). (N.C.)

  9. Applicability of ambient dose equivalent H*(d) in mixed radiation fields - a critical discussion

    International Nuclear Information System (INIS)

    Hajek, M.; Vana, N.

    2004-01-01

    For purposes of routine radiation protection, it is desirable to characterize the potential irradiation of individuals in terms of a single dose equivalent quantity that would exist in a phantom approximating the human body. The phantom of choice is the ICRU sphere made of 30 cm diameter tissue-equivalent plastic with a density of 1 g.cm-3 and a mass composition of 76.2 % O, 11.1 % C, 10.1 % H and 2.6 % N. Ambient dose equivalent, H*(d), was defined in ICRU report 51 as the dose equivalent that would be produced by an expanded and aligned radiation field at a depth d in the ICRU sphere. The recommended reference depths are 10 mm for strongly penetrating radiation and 0.07 mm for weakly penetrating radiation, respectively. As an operational quantity in radiation protection, H*(d) shall serve as a conservative and directly measurable estimate of protection quantities, e.g. effective dose E, which in turn are intended to give an indication of the risk associated with radiation exposure. The situation attains increased complexity in radiation environments being composed of a variety of charged and uncharged particles in a broad energetic spectrum. Radiation fields of similarly complex nature are, for example, encountered onboard aircraft and in space. Dose equivalent was assessed as a function of depth in quasi tissue-equivalent spheres by means of thermoluminescent dosemeters evaluated according to the high-temperature ratio (HTR) method. The presented experiments were performed both onboard aircraft and the Russian space station Mir. As a result of interaction processes within the phantom body, the incident primary spectrum may be significantly modified with increasing depth. For the radiation field at aviation altitudes we found the maximum of dose equivalent in a depth of 60 mm which conflicts with the 10 mm value recommended by ICRU. Contrary, for the space radiation environment the maximum dose equivalent was found at the surface of the sphere. This suggests that

  10. Applicability of Ambient Dose Equivalent H (d) in Mixed Radiation Fields - A Critical Discussion

    International Nuclear Information System (INIS)

    Vana, R.; Hajek, M.; Bergerm, T.

    2004-01-01

    For purposes of routine radiation protection, it is desirable to characterize the potential irradiation of individuals in terms of a single dose equivalent quantity that would exist in a phantom approximating the human body. The phantom of choice is the ICRU sphere made of 30 cm diameter tissue-equivalent plastic with a density of 1 g/cm3 and a mass composition of 76.2% O, 11.1% C, 10.1% H and 2.6% N. Ambient dose equivalent, H(d), was defined in ICRU report 51 as the dose equivalent that would be produced by an expanded and aligned radiation field at a depth d in the ICRU sphere. The recommended reference depths are 10 mm for strongly penetrating radiation and 0.07 mm for weakly penetrating radiation, respectively. As an operational quantity in radiation protection, H(d) shall serve as a conservative and directly measurable estimate of protection quantities, e.g. effective dose E, which in turn are intended to give an indication of the risk associated with radiation exposure. The situation attains increased complexity in radiation environments being composed of a variety of charged and uncharged particles in a broad energetic spectrum. Radiation fields of similarly complex nature are, for example, encountered onboard aircraft and in space. Dose equivalent was assessed as a function of depth in quasi tissue-equivalent spheres by means of thermoluminescent dosemeters evaluated according to the high-temperature ratio (HTR) method. The presented experiments were performed both onboard aircraft and the Russian space station Mir. As a result of interaction processes within the phantom body, the incident primary spectrum may be significantly modified with increasing depth. For the radiation field at aviation altitudes we found the maximum of dose equivalent in a depth of 60 mm which conflicts with the 10 mm value recommended by ICRU. Contrary, for the space radiation environment the maximum dose equivalent was found at the surface of the sphere. This suggests that skin

  11. Effective dose equivalent to the operator in intra-oral dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    de Haan, R.A.; van Aken, J. (Utrecht Univ., (The Netherlands))

    1990-08-01

    The effective dose equivalent to the operator in intra-oral dental radiography has been determined. The exposure from a bitewing radiograph and periapical views of the left maxillary incisors and first molar was measured at nine heights and 16 positions, all 1 m from the patient. The effective dose equivalent was determined using data from ICRP 51 (International Commission on Radiological Protection: Data for Use in Protection Against External Radiation). The values presented are related to an exposure of 1 C kg-1 (3876 R) measured free in air at the tube-end. They thus constitute ratios which are not influenced by the sensitivity of the film or other detector used and form standard tables which permit the calculation of the effective dose equivalent in clinical situations.

  12. Effective dose equivalent to the operator in intra-oral dental radiography

    International Nuclear Information System (INIS)

    de Haan, R.A.; van Aken, J.

    1990-01-01

    The effective dose equivalent to the operator in intra-oral dental radiography has been determined. The exposure from a bitewing radiograph and periapical views of the left maxillary incisors and first molar was measured at nine heights and 16 positions, all 1 m from the patient. The effective dose equivalent was determined using data from ICRP 51 (International Commission on Radiological Protection: Data for Use in Protection Against External Radiation). The values presented are related to an exposure of 1 C kg-1 (3876 R) measured free in air at the tube-end. They thus constitute ratios which are not influenced by the sensitivity of the film or other detector used and form standard tables which permit the calculation of the effective dose equivalent in clinical situations

  13. A comparison of the angular dependence of effective dose and effective dose equivalent

    International Nuclear Information System (INIS)

    Sitek, M.A.; Gierga, D.P.; Xu, X.G.

    1996-01-01

    In ICRP (International Commission on Radiological Protection) Publication 60, the set of critical organs and their weighing factors were changed, defining the quantity effective dose, E. This quantity replaced the effective dose equivalent, H E , as defined by ICRP 26. Most notably, the esophagus was added to the list of critical organs. The Monte Carlo neutron/photon transport code MCNP was used to determine the effective dose to sex-specific anthropomorphic phantoms. The phantoms, developed in previous research, were modified to include the esophagus. Monte Carlo simulations were performed for monoenergetic photon beams of energies 0.08 MeV, 0.3 MeV, and 1.0 MeV for various azimuthal and polar angles. Separate organ equivalent doses were determined for male and female phantoms. The resulting organ equivalent doses were calculated from arithmetic mean averages. The angular dependence of effective dose was compared with that of effective dose equivalent reported in previous research. The differences between the two definitions and possible implications to regulatory agencies were summarized

  14. Response of radiation monitors for ambient dose equivalent, H*(10)

    International Nuclear Information System (INIS)

    Grecco, Claudio Henrique dos Santos

    2001-01-01

    Radiation monitors are used all over the world to evaluate if places with presence of ionising radiation present safe conditions for people. Radiation monitors should be tested according to international or national standards in order to be qualified for use. This work describes a methodology and procedures to evaluate the energy and angular responses of any radiation monitor for ambient dose equivalent, H*(10), according to the recommendations of ISO and IEC standards. The methodology and the procedures were applied to the Monitor Inteligente de Radiacao MIR 7026, developed by the Instituto em Engenharia Nuclear (IEN), to evaluate and to adjust its response for H*(10), characterizing it as an ambient dose equivalent meter. The tests were performed at the Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI), at Instituto de Radioprotecao e Dosimetria (IRD), and results showed that the Monitor Inteligente de Radiacao MIR 7026 can be used as an EI*(10) meter, in accordance to the IEC 60846 standard requirements. The overall estimated uncertainty for the determination of the MIR 7026 response, in all radiation qualities used in this work, was 4,5 % to a 95 % confidence limit. (author)

  15. Experimental method research on neutron equal dose-equivalent detection

    International Nuclear Information System (INIS)

    Ji Changsong

    1995-10-01

    The design principles of neutron dose-equivalent meter for neutron biological equi-effect detection are studied. Two traditional principles 'absorption net principle' and 'multi-detector principle' are discussed, and on the basis of which a new theoretical principle for neutron biological equi-effect detection--'absorption stick principle' has been put forward to place high hope on both increasing neutron sensitivity of this type of meters and overcoming the shortages of the two traditional methods. In accordance with this new principle a brand-new model of neutron dose-equivalent meter BH3105 has been developed. Its neutron sensitivity reaches 10 cps/(μSv·h -1 ), 18∼40 times higher than that of all the same kinds of meters 0.23∼0.56 cps/(μSv·h -1 ), available today at home and abroad and the specifications of the newly developed meter reach or surpass the levels of the same kind of meters. Therefore the new theoretical principle of neutron biological equi-effect detection--'absorption stick principle' is proved to be scientific, advanced and useful by experiments. (3 refs., 3 figs., 2 tabs.)

  16. Estimates of effective equivalent dose commitments for Slovene population following the Chernobyl accident

    International Nuclear Information System (INIS)

    Kanduc, M.; Jovanowic, O.; Kuhar, B.

    2004-01-01

    This paper shows the estimates of effective equivalent dose commitments for the two groups of Slovene population, 5 years old children and adults. Doses were calculated on the basis of the ICRP 30 methodology, first from the measurements of the concentrations of the radionuclides in air, water and food samples and then compared with the results of the measurements of radionuclides in composite samples of the prepared food, taken in the kindergarten nearby. Results show that there is certain degree of conservatism hidden in the calculation of the doses on the basis of measurements of the activity concentration in the elements of the biosphere and is estimated to be roughly 50%. (author)

  17. Aircraft crew radiation workplaces: Comparison of measured and calculated ambient dose equivalent rate data using the EURADOS in-flight radiation data base

    Czech Academy of Sciences Publication Activity Database

    Beck, P.; Bartlett, D.; Lindborg, L.; McAulay, I.; Schnuer, K.; Schraube, H.; Spurný, František

    2006-01-01

    Roč. 118, č. 2 (2006), s. 182-189 ISSN 0144-8420 R&D Projects: GA MŠk 1P05OC032 Institutional research plan: CEZ:AV0Z10480505 Keywords : aircraft crew radiation * carbon ions beam * measurement results Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.446, year: 2006

  18. Calculation of the dose equivalent around a patient receiving treatment with {sup 125}I seeds

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Toru; Dokiya, Takushi; Toya, Kazuhito; Kawase, Takatsugu [National Tokyo Medical Center Hospital (Japan); Hashimoto, Mitsuyasu

    2001-03-01

    Interstitial brachytherapy with {sup 125}I seeds for treatment of prostate cancer is being carried out successfully in Europe and U.S.A. However, its widespread use in Japan has been limited by regulations governing the exposure of individuals. Basic radiation protection data are required to promote the use of {sup 125}I seed sources. In preparation for implementing this new modality, we carried out a series of measurements to determine the 1 cm dose equivalent in a caregiver located 1 m from the implanted patient. These measurements were compared with published recommendations of acceptable doses, and may be used to develop guidelines for discharge of the patient. The 1 cm dose equivalent was measured 1 m from the source under clinically relevant conditions by placing 50 {sup 125}I seeds (437.5 MBq) into the portion of a humanoid phantom that corresponds to the prostate. The 1 cm dose equivalent was 0.0014 {mu}Sv{center_dot}m{sup 2}{center_dot}MBq{sup -1}{center_dot}h{sup -1} 1 m from the surface of the phantom. The calculated dose to a caregiver based on this figure is well below the 5 mSv value recommended by the IAEA as a constraint dose for the caregiver. These measurements and calculations suggest that {sup 125}I seed implants of outpatients should be permissible. (author)

  19. Out‐of‐field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators

    Science.gov (United States)

    Cardenas, Carlos E.; Nitsch, Paige L.; Kudchadker, Rajat J.; Howell, Rebecca M.

    2016-01-01

    Out‐of‐field doses from radiotherapy can cause harmful side effects or eventually lead to secondary cancers. Scattered doses outside the applicator field, neutron source strength values, and neutron dose equivalents have not been broadly investigated for high‐energy electron beams. To better understand the extent of these exposures, we measured out‐of‐field dose characteristics of electron applicators for high‐energy electron beams on two Varian 21iXs, a Varian TrueBeam, and an Elekta Versa HD operating at various energy levels. Out‐of‐field dose profiles and percent depth‐dose curves were measured in a Wellhofer water phantom using a Farmer ion chamber. Neutron dose was assessed using a combination of moderator buckets and gold activation foils placed on the treatment couch at various locations in the patient plane on both the Varian 21iX and Elekta Versa HD linear accelerators. Our findings showed that out‐of‐field electron doses were highest for the highest electron energies. These doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. The Elekta linear accelerator had higher electron out‐of‐field doses than the Varian units examined, and the Elekta dose profiles exhibited a second dose peak about 20 to 30 cm from central‐axis, which was found to be higher than typical out‐of‐field doses from photon beams. Electron doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. With respect to neutron dosimetry, Q values and neutron dose equivalents increased with electron beam energy. Neutron contamination from electron beams was found to be much lower than that from photon beams. Even though the neutron dose equivalent for electron beams represented a small portion of neutron doses observed under photon beams, neutron doses from electron beams may need to be considered for

  20. Out-of-field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators.

    Science.gov (United States)

    Cardenas, Carlos E; Nitsch, Paige L; Kudchadker, Rajat J; Howell, Rebecca M; Kry, Stephen F

    2016-07-08

    Out-of-field doses from radiotherapy can cause harmful side effects or eventually lead to secondary cancers. Scattered doses outside the applicator field, neutron source strength values, and neutron dose equivalents have not been broadly investigated for high-energy electron beams. To better understand the extent of these exposures, we measured out-of-field dose characteristics of electron applicators for high-energy electron beams on two Varian 21iXs, a Varian TrueBeam, and an Elekta Versa HD operating at various energy levels. Out-of-field dose profiles and percent depth-dose curves were measured in a Wellhofer water phantom using a Farmer ion chamber. Neutron dose was assessed using a combination of moderator buckets and gold activation foils placed on the treatment couch at various locations in the patient plane on both the Varian 21iX and Elekta Versa HD linear accelerators. Our findings showed that out-of-field electron doses were highest for the highest electron energies. These doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. The Elekta linear accelerator had higher electron out-of-field doses than the Varian units examined, and the Elekta dose profiles exhibited a second dose peak about 20 to 30 cm from central-axis, which was found to be higher than typical out-of-field doses from photon beams. Electron doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. With respect to neutron dosimetry, Q values and neutron dose equivalents increased with electron beam energy. Neutron contamination from electron beams was found to be much lower than that from photon beams. Even though the neutron dose equivalent for electron beams represented a small portion of neutron doses observed under photon beams, neutron doses from electron beams may need to be considered for special cases.

  1. Committed equivalent organ doses and committed effective doses from intakes of radionuclides

    CERN Document Server

    Phipps, A W; Kendall, G M; Silk, T J; Stather, J W

    1991-01-01

    This report contains details of committed equivalent doses to individual organs for intakes by ingestion and inhalation of 1 mu m AMAD particles of 359 nuclides by infants aged 3 months, by children aged 1, 5, 10 and 15 years, and by adults. It complements NRPB-R245 which describes the changes which have taken place since the last NRPB compendium of dose per unit intake factors (dose coefficients) and gives summary tables. Information on the way committed doses increase with the integration period is given in NRPB-M289. The information given in these memoranda is also available as a microcomputer package - NRPB-SR245.

  2. Comparison of organ dose and dose equivalent for human phantoms of CAM vs. MAX

    Science.gov (United States)

    Kim, Myung-Hee Y.; Qualls, Garry D.; Slaba, Tony C.; Cucinotta, Francis A.

    2010-04-01

    For the evaluation of organ dose and dose equivalent of astronauts on space shuttle and the International Space Station (ISS) missions, the CAMERA models of CAM (Computerized Anatomical Male) and CAF (Computerized Anatomical Female) of human tissue shielding have been implemented and used in radiation transport model calculations at NASA. One of new human geometry models to meet the “reference person” of International Commission on Radiological Protection (ICRP) is based on detailed Voxel (volumetric and pixel) phantom models denoted for male and female as MAX (Male Adult voXel) and FAX (Female Adult voXel), respectively. We compared the CAM model predictions of organ doses to those of MAX model, since the MAX model represents the male adult body with much higher fidelity than the CAM model currently used at NASA. Directional body-shielding mass was evaluated for over 1500 target points of MAX for specified organs considered to be sensitive to the induction of stochastic effects. Radiation exposures to solar particle event (SPE), trapped protons, and galactic cosmic ray (GCR) were assessed at the specific sites in the MAX phantom by coupling space radiation transport models with the relevant body-shielding mass. The development of multiple-point body-shielding distributions at each organ made it possible to estimate the mean and variance of organ doses at the specific organ. For the estimate of doses to the blood forming organs (BFOs), data on active marrow distributions in adult were used to weight the bone marrow sites over the human body. The discrete number of target points of MAX organs resulted in a reduced organ dose and dose equivalent compared to the results of CAM organs especially for SPE, and should be further investigated. Differences of effective doses between the two approaches were found to be small (<5%) for GCR.

  3. Comparison of dose calculation algorithms in slab phantoms with cortical bone equivalent heterogeneities

    International Nuclear Information System (INIS)

    Carrasco, P.; Jornet, N.; Duch, M. A.; Panettieri, V.; Weber, L.; Eudaldo, T.; Ginjaume, M.; Ribas, M.

    2007-01-01

    To evaluate the dose values predicted by several calculation algorithms in two treatment planning systems, Monte Carlo (MC) simulations and measurements by means of various detectors were performed in heterogeneous layer phantoms with water- and bone-equivalent materials. Percentage depth doses (PDDs) were measured with thermoluminescent dosimeters (TLDs), metal-oxide semiconductor field-effect transistors (MOSFETs), plane parallel and cylindrical ionization chambers, and beam profiles with films. The MC code used for the simulations was the PENELOPE code. Three different field sizes (10x10, 5x5, and 2x2 cm 2 ) were studied in two phantom configurations and a bone equivalent material. These two phantom configurations contained heterogeneities of 5 and 2 cm of bone, respectively. We analyzed the performance of four correction-based algorithms and one based on convolution superposition. The correction-based algorithms were the Batho, the Modified Batho, the Equivalent TAR implemented in the Cadplan (Varian) treatment planning system (TPS), and the Helax-TMS Pencil Beam from the Helax-TMS (Nucletron) TPS. The convolution-superposition algorithm was the Collapsed Cone implemented in the Helax-TMS. All the correction-based calculation algorithms underestimated the dose inside the bone-equivalent material for 18 MV compared to MC simulations. The maximum underestimation, in terms of root-mean-square (RMS), was about 15% for the Helax-TMS Pencil Beam (Helax-TMS PB) for a 2x2 cm 2 field inside the bone-equivalent material. In contrast, the Collapsed Cone algorithm yielded values around 3%. A more complex behavior was found for 6 MV where the Collapsed Cone performed less well, overestimating the dose inside the heterogeneity in 3%-5%. The rebuildup in the interface bone-water and the penumbra shrinking in high-density media were not predicted by any of the calculation algorithms except the Collapsed Cone, and only the MC simulations matched the experimental values within

  4. Comparison of dose calculation algorithms in slab phantoms with cortical bone equivalent heterogeneities.

    Science.gov (United States)

    Carrasco, P; Jornet, N; Duch, M A; Panettieri, V; Weber, L; Eudaldo, T; Ginjaume, M; Ribas, M

    2007-08-01

    To evaluate the dose values predicted by several calculation algorithms in two treatment planning systems, Monte Carlo (MC) simulations and measurements by means of various detectors were performed in heterogeneous layer phantoms with water- and bone-equivalent materials. Percentage depth doses (PDDs) were measured with thermoluminescent dosimeters (TLDs), metal-oxide semiconductor field-effect transistors (MOSFETs), plane parallel and cylindrical ionization chambers, and beam profiles with films. The MC code used for the simulations was the PENELOPE code. Three different field sizes (10 x 10, 5 x 5, and 2 x 2 cm2) were studied in two phantom configurations and a bone equivalent material. These two phantom configurations contained heterogeneities of 5 and 2 cm of bone, respectively. We analyzed the performance of four correction-based algorithms and one based on convolution superposition. The correction-based algorithms were the Batho, the Modified Batho, the Equivalent TAR implemented in the Cadplan (Varian) treatment planning system (TPS), and the Helax-TMS Pencil Beam from the Helax-TMS (Nucletron) TPS. The convolution-superposition algorithm was the Collapsed Cone implemented in the Helax-TMS. All the correction-based calculation algorithms underestimated the dose inside the bone-equivalent material for 18 MV compared to MC simulations. The maximum underestimation, in terms of root-mean-square (RMS), was about 15% for the Helax-TMS Pencil Beam (Helax-TMS PB) for a 2 x 2 cm2 field inside the bone-equivalent material. In contrast, the Collapsed Cone algorithm yielded values around 3%. A more complex behavior was found for 6 MV where the Collapsed Cone performed less well, overestimating the dose inside the heterogeneity in 3%-5%. The rebuildup in the interface bone-water and the penumbra shrinking in high-density media were not predicted by any of the calculation algorithms except the Collapsed Cone, and only the MC simulations matched the experimental values

  5. Determination of the conversion coefficient for ambient dose equivalent, H(10), from air kerma measurements; Determinacion del coeficiente de conversion para la dosis equivalente ambiental, H*(10), a partir de mediciones de kerma en aire

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez J, F. [UNAM, Facultad de Ciencias, Circuito Exterior, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico); Alvarez R, J. T., E-mail: trinidad.alvarez@inin.gob.mx [ININ, Departamento de Metrologia de Radiaciones Ionizantes, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    Namely the operational magnitudes can be determined by the product of a conversion coefficient by exposure air kerma or fluence, etc. In particular in Mexico for the first time is determined the conversion coefficient (Cc) for operational magnitude Environmental Dose Equivalent H(10) by thermoluminescence dosimetry (TLD) technique. First 30 TLD-100 dosimeters are calibrated in terms of air kerma, then these dosimeters are irradiated inside a sphere ICRU type of PMMA and with the aid of theory cavity the absorbed dose in PMMA is determined at a depth of 10 mm within the sphere D{sub PMMA}(10), subsequently absorbed dose to ICRU tissue is corrected and the dose equivalent H(10) is determined. The Cc is determined as the ratio of H(10)/K{sub a} obtaining a value of 1.20 Sv Gy{sup -1} with a u{sub c}= 3.66%, this being consistent with the published value in ISO-4037-3 of 1.20 Sv Gy{sup -1} with a u{sub c}= 2%. (Author)

  6. Method to account for dose fractionation in analysis of IMRT plans: Modified equivalent uniform dose

    International Nuclear Information System (INIS)

    Park, Clinton S.; Kim, Yongbok; Lee, Nancy; Bucci, Kara M.; Quivey, Jeanne M.; Verhey, Lynn J.; Xia Ping

    2005-01-01

    Purpose: To propose a modified equivalent uniform dose (mEUD) to account for dose fractionation using the biologically effective dose without losing the advantages of the generalized equivalent uniform dose (gEUD) and to report the calculated mEUD and gEUD in clinically used intensity-modulated radiotherapy (IMRT) plans. Methods and Materials: The proposed mEUD replaces the dose to each voxel in the gEUD formulation by a biologically effective dose with a normalization factor. We propose to use the term mEUD D o /n o that includes the total dose (D o ) and number of fractions (n o ) and to use the term mEUD o that includes the same total dose but a standard fraction size of 2 Gy. A total of 41 IMRT plans for patients with nasopharyngeal cancer treated at our institution between October 1997 and March 2002 were selected for the study. The gEUD and mEUD were calculated for the planning gross tumor volume (pGTV), planning clinical tumor volume (pCTV), parotid glands, and spinal cord. The prescription dose for these patients was 70 Gy to >95% of the pGTV and 59.4 Gy to >95% of the pCTV in 33 fractions. Results: The calculated average gEUD was 72.2 ± 2.4 Gy for the pGTV, 54.2 ± 7.1 Gy for the pCTV, 26.7 ± 4.2 Gy for the parotid glands, and 34.1 ± 6.8 Gy for the spinal cord. The calculated average mEUD D o /n o using 33 fractions was 71.7 ± 3.5 Gy for mEUD 70/33 of the pGTV, 49.9 ± 7.9 Gy for mEUD 59.5/33 of the pCTV, 27.6 ± 4.8 Gy for mEUD 26/33 of the parotid glands, and 32.7 ± 7.8 Gy for mEUD 45/33 of the spinal cord. Conclusion: The proposed mEUD, combining the gEUD with the biologically effective dose, preserves all advantages of the gEUD while reflecting the fractionation effects and linear and quadratic survival characteristics

  7. Calibration and background measurements with a tissue equivalent proportional counter

    International Nuclear Information System (INIS)

    Autischer, M.; Beck, P.; Rollet, S.; Kindl, P.; Latocha, M.

    2005-01-01

    Full text: A TEPC (tissue equivalent proportional counter) instrument has been used as the reference instrument for cosmic radiation measurement at flight altitudes by several institutes. For characterization purposes the instrument response has been investigated under different standard radiation conditions, in terms of radiation particle, energy and angular direction. Photon sources and photon beams up to 6 MeV and neutron beams up to 200MeV were used. To deepen understanding the shielding influence of the instrument assembly, the angle dependency were analyzed for several radiation conditions. Specific measurement conditions were simulated with the Monte Carlo transport code FLUKA. The measured instrument response is compared with simulation results. lt is demonstrated, that simulation are very helpful to understand the instruments response. The used TEPC instrument of the Austrian Research Center Seibersdorf (ARCS) simulates the energy deposition in a cell size tissue volume of 2 μm diameter. Pure propane at low pressure is used as measurement gas. To characterize the instrument at low dose rates, background measurements were done about 800 m below ground and at the ultra low level laboratory in Gran Sasso, 1380 m below ground. These results were compared with measurements on earth's surface at different altitudes on mountains up to 3480 m above the sea level. The significant increase of the expected dose rate is well reproduced by the experiments at mountain altitudes. As a result of this study a full characterization and a complete understanding of the performance and reliability of the detector is achieved. (author)

  8. Ambient neutron dose equivalent outside concrete vault rooms for 15 and 18 MV radiotherapy accelerators

    International Nuclear Information System (INIS)

    Martinez-ovalle, S. A.; Barquero, R.; Gomez-ros, J. M.; Lallena, A. M.

    2012-01-01

    In this work, the ambient dose equivalent, H*(10), due to neutrons outside three bunkers that house a 15- and a 18-MV Varian Clinac 2100C/D and a 15-MV Elekta Inor clinical linacs, has been calculated. The Monte Carlo code MCNPX (v. 2.5) has been used to simulate the neutron production and transport. The complete geometries including linacs and full installations have been built up according to the specifications of the manufacturers and the planes provided by the corresponding medical physical services of the hospitals where the three linacs operate. Two of these installations, those lodging the Varian linacs, have an entrance door to the bunker while the other one does not, although it has a maze with two bends. Various treatment orientations were simulated in order to establish plausible annual equivalent doses. Specifically anterior-posterior, posterior-anterior, left lateral, right lateral orientations and an additional one with the gantry rotated 30 deg. have been studied. Significant dose rates have been found only behind the walls and the door of the bunker, near the entrance and the console, with a maximum of 12 μSv h -1 . Dose rates per year have been calculated assuming a conservative workload for the three facilities. The higher dose rates in the corresponding control areas were 799 μSv y -1 , in the case of the facility which operates the 15-MV Clinac, 159 μSv y -1 , for that with the 15-MV Elekta, and 21 μSv y -1 for the facility housing the 18-MV Varian. A comparison with measurements performed in similar installations has been carried out and a reasonable agreement has been found. The results obtained indicate that the neutron contamination does not increase the doses above the legal limits and does not produce a significant enhancement of the dose equivalent calculated. When doses are below the detection limits provided by the measuring devices available today, MCNPX simulation provides an useful method to evaluate neutron dose equivalents

  9. Assessment of organ equivalent doses and effective doses from diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Park, Sang Hyun

    2003-02-01

    The MIRD-type adult male, female and age 10 phantoms were constructed to evaluate organ equivalent dose and effective dose of patient due to typical diagnostic X-ray examination. These phantoms were constructed with external and internal dimensions of Korean. The X-ray energy spectra were generated with SPEC78. MCNP4B ,the general-purposed Monte Carlo code, was used. Information of chest PA , chest LAT, and abdomen AP diagnostic X-ray procedures was collected on the protocol of domestic hospitals. The results showed that patients pick up approximate 0.02 to 0.18 mSv of effective dose from a single chest PA examination, and 0.01 to 0.19 mSv from a chest LAT examination depending on the ages. From an abdomen AP examination, patients pick up 0.17 to 1.40 mSv of effective dose. Exposure time, organ depth from the entrance surface and X-ray beam field coverage considerably affect the resulting doses. Deviation among medical institutions is somewhat high, and this indicated that medical institutions should interchange their information and the need of education for medical staff. The methodology and the established system can be applied, with some expansion, to dose assessment for other medical procedures accompanying radiation exposure of patients like nuclear medicine or therapeutic radiology

  10. Investigation of 1-cm dose equivalent for photons behind shielding materials

    International Nuclear Information System (INIS)

    Hirayama, Hideo; Tanaka, Shun-ichi

    1991-03-01

    The ambient dose equivalent at 1-cm depth, assumed equivalent to the 1-cm dose equivalent in practical dose estimations behind shielding slabs of water, concrete, iron or lead for normally incident photons having various energies was calculated by using conversion factors for a slab phantom. It was compared with the 1-cm depth dose calculated with the Monte Carlo code EGS4. It was concluded from this comparison that the ambient dose equivalent calculated by using the conversion factors for the ICRU sphere could be used for the evaluation of the 1-cm dose equivalent for the sphere phantom within 20% errors. Average and practical conversion factors are defined as the conversion factors from exposure to ambient dose equivalent in a finite slab or an infinite one, respectively. They were calculated with EGS4 and the discrete ordinates code PALLAS. The exposure calculated with simple estimation procedures such as point kernel methods can be easily converted to ambient dose equivalent by using these conversion factors. The maximum value between 1 and 30 mfp can be adopted as the conversion factor which depends only on material and incident photon energy. This gives the ambient dose equivalent on the safe side. 13 refs., 7 figs., 2 tabs

  11. Risk measurement with equivalent utility principles

    NARCIS (Netherlands)

    Denuit, M.; Dhaene, J.; Goovaerts, M.; Kaas, R.; Laeven, R.

    2006-01-01

    Risk measures have been studied for several decades in the actuarial literature, where they appeared under the guise of premium calculation principles. Risk measures and properties that risk measures should satisfy have recently received considerable attention in the financial mathematics

  12. Risk equivalent of exposure versus dose of radiation

    International Nuclear Information System (INIS)

    Bond, V.P.

    1986-01-01

    This report describes a risk analysis study of low-dose irradiation and the resulting biological effects on a cell. The author describes fundamental differences between the effects of high-level exposure (HLE) and low-level exposure (LLE). He stresses that the concept of absorbed dose to an organ is not a dose but a level of effect produced by a particular number of particles. He discusses the confusion between a linear-proportional representation of dose limits and a threshold-curvilinear representation, suggesting that a LLE is a composite of both systems

  13. Measurement of conversion coefficients between air Kerma and personal dose equivalent and backscatter factors for diagnostic X-ray beams; Determinacao experimental dos coeficientes de conversao de Kerma no ar para o equivalente de dose pessoal, Hp(d), e fatores de retroespalhamento em feixes de raios-x diagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Rosado, Paulo Henrique Goncalves

    2008-07-01

    Two sets of quantities are import in radiological protection: the protection and operational quantities. Both sets can be related to basic physical quantities such as kerma through conversion coefficients. For diagnostic x-ray beams the conversion coefficients and backscatter factors have not been determined yet, those parameters are need for calibrating dosimeters that will be used to determine the personal dose equivalent or the entrance skin dose. Conversion coefficients between air kerma and personal dose equivalent and backscatter factors were experimentally determined for the diagnostic x-ray qualities RQR and RQA recommended by the International Electrotechnical Commission (IEC). The air kerma in the phantom and the mean energy of the spectrum were measured for such purpose. Harshaw LiF-100H thermoluminescent dosemeters (TLD) were used for measurements after being calibrated against an 180 cm{sup 3} Radcal Corporation ionization chamber traceable to a reference laboratory. A 300 mm x 300 mm x 150 mm polymethylmethacrylate (PMMA) slab phantom was used for deep-dose measurements. Tl dosemeters were placed in the central axis of the x-ray beam at 5, 10, 15, 25 and 35 mm depth in the phantom upstream the beam direction Another required parameter for determining the conversion coefficients from was the mean energy of the x-ray spectrum. The spectroscopy of x-ray beams was done with a CdTe semiconductor detector that was calibrated with {sup 133} Ba, {sup 241} Am and {sup 57} Co radiation sources. Measurements of the x-ray spectra were carried out for all RQR and RQA IEC qualities. Corrections due to the detector intrinsic efficiency, total energy absorption, escape fraction of the characteristic x-rays, Compton effect and attenuation in the detector were done aiming an the accurate determination of the mean energy. Measured x-ray spectra were corrected with the stripping method by using these response functions. The typical combined standard uncertainties of

  14. Implementation of an Analytical Model for Leakage Neutron Equivalent Dose in a Proton Radiotherapy Planning System

    Directory of Open Access Journals (Sweden)

    John Eley

    2015-03-01

    Full Text Available Equivalent dose from neutrons produced during proton radiotherapy increases the predicted risk of radiogenic late effects. However, out-of-field neutron dose is not taken into account by commercial proton radiotherapy treatment planning systems. The purpose of this study was to demonstrate the feasibility of implementing an analytical model to calculate leakage neutron equivalent dose in a treatment planning system. Passive scattering proton treatment plans were created for a water phantom and for a patient. For both the phantom and patient, the neutron equivalent doses were small but non-negligible and extended far beyond the therapeutic field. The time required for neutron equivalent dose calculation was 1.6 times longer than that required for proton dose calculation, with a total calculation time of less than 1 h on one processor for both treatment plans. Our results demonstrate that it is feasible to predict neutron equivalent dose distributions using an analytical dose algorithm for individual patients with irregular surfaces and internal tissue heterogeneities. Eventually, personalized estimates of neutron equivalent dose to organs far from the treatment field may guide clinicians to create treatment plans that reduce the risk of late effects.

  15. Eye lens dose correlations with personal dose equivalent and patient exposure in paediatric interventional cardiology performed with a fluoroscopic biplane system.

    Science.gov (United States)

    Alejo, L; Koren, C; Corredoira, E; Sánchez, F; Bayón, J; Serrada, A; Guibelalde, E

    2017-04-01

    To analyse the correlations between the eye lens dose estimates performed with dosimeters placed next to the eyes of paediatric interventional cardiologists working with a biplane system, the personal dose equivalent measured on the thorax and the patient dose. The eye lens dose was estimated in terms of H p (0.07) on a monthly basis, placing optically stimulated luminescence dosimeters (OSLDs) on goggles. The H p (0.07) personal dose equivalent was measured over aprons with whole-body OSLDs. Data on patient dose as recorded by the kerma-area product (P KA ) were collected using an automatic dose management system. The 2 paediatric cardiologists working in the facility were involved in the study, and 222 interventions in a 1-year period were evaluated. The ceiling-suspended screen was often disregarded during interventions. The annual eye lens doses estimated on goggles were 4.13±0.93 and 4.98±1.28mSv. Over the aprons, the doses obtained were 10.83±0.99 and 11.97±1.44mSv. The correlation between the goggles and the apron dose was R 2 =0.89, with a ratio of 0.38. The correlation with the patient dose was R 2 =0.40, with a ratio of 1.79μSvGy -1 cm -2 . The dose per procedure obtained over the aprons was 102±16μSv, and on goggles 40±9μSv. The eye lens dose normalized to P KA was 2.21±0.58μSvGy -1 cm -2 . Measurements of personal dose equivalent over the paediatric cardiologist's apron are useful to estimate eye lens dose levels if no radiation protection devices are typically used. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  16. Assessment of equivalent dose on the lens in cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, M. V. L.; Campos, P. S. F. [Federal University of Bahia, Department of Health Sciences, Salvador (Brazil); Andrade, M. E. A. [Federal University of Pernambuco, Department of Nuclear Energy, Recife (Brazil); Soares, M. R. [Federal University of Sergipe, Department of Physics, Sao Cristovao (Brazil); Batista, W. O., E-mail: marcusradiology@gmail.com [Federal Institute of Bahia, Department of Applied Sciences, 40.301-015 Salvador (Brazil)

    2014-08-15

    The Cone Beam Computed Tomography (CBCT) is presented as a useful test method for the evaluation of craniofacial structures. Among them stands the temporomandibular joint (T MJ) imaging as complementary to clinical evaluation. It must be considered that there is no reference levels established for diagnosis of this imaging modality. In this same context, recently the limit for crystalline lens was reviewed by ICRP which set new values to the equivalent dose. The aim of this study was to evaluate the kerma at the surface of the crystalline lens in T MJ CBCT and derive the equivalent dose. It was used an anthropomorphic phantom of the head and neck (manufactured by: Radiation Support Devices, model; Rs-230) containing equivalent tissue with dimensions of a typical patient. The dosimetric measurements were obtained by using seven pairs of thermoluminescent dosimetry (TLD) dosimeters (LiF: Mg, Ti) positioned on the surface of the crystalline lens, divided into two pairs (one pair for each eye) per scanner evaluated. The tomographic images were obtained in three CBCT equipment s (Kodak 9000, Gendex GXCB 500 and i-Cat). Values of equivalent dose obtained were: 5.82 mSv (Kodak 9000); 5.38 mSv (Gendex GXCB 500) and 7.98 mSv (i-Cat). These results demonstrate that for this type of procedure the doses are below the annual limit but may vary in accordance with the scanner and the exposure factors used in the image acquisition. The Gendex GXCB500 uses larger Fov and higher kV. It results in levels close to those obtained on Kodak 9000. Larger doses are associated with the i-Cat. Another factor that rises is the repetition of examinations due to positioning errors and / or patient movement, which may exceed the annual limit established by ICRP. Although the ICRP limits are not applied to medical exposures, it is advisable to consider the sensitivity of the organ. For this reason, it is concluded that doses per T MJ procedure on CBCT are below the annual limit and may vary

  17. Reduction of outdoor and indoor ambient dose equivalent after decontamination in the Fukushima evacuation zones

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida-Ohuchi, Hiroko; Kanagami, Takashi [Graduate School of Pharmaceutical Sciences, Tohoku University, Miyagi (Japan); Naitoh, Yutaka; Kameyama, Mizuki [Japan Environment Research Co., Ltd., Miyagi (Japan); Hosoda, Masahiro [Dept. of Radiological Life Sciences, Hirosaki University Graduate School of Health Sciences, Aomori (Japan)

    2017-03-15

    One of the most urgent issues following the accident at the Fukushima Daiichi nuclear power plant (FDNPP) was the remediation of the land, in particular, for residential area contaminated by the radioactive materials discharged. In this study, the effect of decontamination on reduction of ambient dose equivalent outdoors and indoors was evaluated. The latter is essential for residents as most individuals spend a large portion of their time indoors. From December 2012 to November 2014, thirty-seven Japanese single-family detached wooden houses were investigated before and after decontamination in evacuation zones. Outdoor and indoor dose measurements (n=84 and 114, respectively) were collected based on in situ measurements using the NaI (Tl) scintillation surveymeter. The outdoor ambient dose equivalents [H{sup *}(10){sub out}] ranged from 0.61 to 3.71 μSv h{sup -1} and from 0.23 to 1.32 μSv h{sup -1} before and after decontamination, respectively. The indoor ambient dose equivalents [H{sup *}(10){sup in}] ranged from 0.29 to 2.53 μSv h{sup -1} and from 0.16 to 1.22 μSv h{sup -1} before and after decontamination, respectively. The values of reduction efficiency (RE), defined as the ratio by which the radiation dose has been reduced via decontamination, were evaluated as 0.47±0.13, 0.51±0.13, and 0.58±0.08 (average±σ) when H{sup *}(10){sub out} <1.0 μSv h{sup -1}, 1.0 μSv h{sup -1} dose is essential as most individuals spend a large portion of their time indoors. The difference between outdoors and indoors should be considered carefully in order to estimate residents’ exposure dose before their returning home.

  18. Evaluation of dose equivalent rate distribution in JCO critical accident by radiation transport calculation

    CERN Document Server

    Sakamoto, Y

    2002-01-01

    In the prevention of nuclear disaster, there needs the information on the dose equivalent rate distribution inside and outside the site, and energy spectra. The three dimensional radiation transport calculation code is a useful tool for the site specific detailed analysis with the consideration of facility structures. It is important in the prediction of individual doses in the future countermeasure that the reliability of the evaluation methods of dose equivalent rate distribution and energy spectra by using of Monte Carlo radiation transport calculation code, and the factors which influence the dose equivalent rate distribution outside the site are confirmed. The reliability of radiation transport calculation code and the influence factors of dose equivalent rate distribution were examined through the analyses of critical accident at JCO's uranium processing plant occurred on September 30, 1999. The radiation transport calculations including the burn-up calculations were done by using of the structural info...

  19. A new online detector for estimation of peripheral neutron equivalent dose in organ

    Energy Technology Data Exchange (ETDEWEB)

    Irazola, L., E-mail: leticia@us.es; Sanchez-Doblado, F. [Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla 41009, Spain and Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41007 (Spain); Lorenzoli, M.; Pola, A. [Departimento di Ingegneria Nuclear, Politecnico di Milano, Milano 20133 (Italy); Bedogni, R. [Laboratori Nazionali di Frascati, Istituto Nazionale di Fisica Nucleare (INFN), Frascati Roma 00044 (Italy); Terrón, J. A. [Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41007 (Spain); Sanchez-Nieto, B. [Instituto de Física, Pontificia Universidad Católica de Chile, Santiago 4880 (Chile); Expósito, M. R. [Departamento de Física, Universitat Autònoma de Barcelona, Bellaterra 08193 (Spain); Lagares, J. I.; Sansaloni, F. [Centro de Investigaciones Energéticas y Medioambientales y Tecnológicas (CIEMAT), Madrid 28040 (Spain)

    2014-11-01

    Purpose: Peripheral dose in radiotherapy treatments represents a potential source of secondary neoplasic processes. As in the last few years, there has been a fast-growing concern on neutron collateral effects, this work focuses on this component. A previous established methodology to estimate peripheral neutron equivalent doses relied on passive (TLD, CR39) neutron detectors exposed in-phantom, in parallel to an active [static random access memory (SRAMnd)] thermal neutron detector exposed ex-phantom. A newly miniaturized, quick, and reliable active thermal neutron detector (TNRD, Thermal Neutron Rate Detector) was validated for both procedures. This first miniaturized active system eliminates the long postprocessing, required for passive detectors, giving thermal neutron fluences in real time. Methods: To validate TNRD for the established methodology, intrinsic characteristics, characterization of 4 facilities [to correlate monitor value (MU) with risk], and a cohort of 200 real patients (for second cancer risk estimates) were evaluated and compared with the well-established SRAMnd device. Finally, TNRD was compared to TLD pairs for 3 generic radiotherapy treatments through 16 strategic points inside an anthropomorphic phantom. Results: The performed tests indicate similar linear dependence with dose for both detectors, TNRD and SRAMnd, while a slightly better reproducibility has been obtained for TNRD (1.7% vs 2.2%). Risk estimates when delivering 1000 MU are in good agreement between both detectors (mean deviation of TNRD measurements with respect to the ones of SRAMnd is 0.07 cases per 1000, with differences always smaller than 0.08 cases per 1000). As far as the in-phantom measurements are concerned, a mean deviation smaller than 1.7% was obtained. Conclusions: The results obtained indicate that direct evaluation of equivalent dose estimation in organs, both in phantom and patients, is perfectly feasible with this new detector. This will open the door to an

  20. A new online detector for estimation of peripheral neutron equivalent dose in organ

    International Nuclear Information System (INIS)

    Irazola, L.; Sanchez-Doblado, F.; Lorenzoli, M.; Pola, A.; Bedogni, R.; Terrón, J. A.; Sanchez-Nieto, B.; Expósito, M. R.; Lagares, J. I.; Sansaloni, F.

    2014-01-01

    Purpose: Peripheral dose in radiotherapy treatments represents a potential source of secondary neoplasic processes. As in the last few years, there has been a fast-growing concern on neutron collateral effects, this work focuses on this component. A previous established methodology to estimate peripheral neutron equivalent doses relied on passive (TLD, CR39) neutron detectors exposed in-phantom, in parallel to an active [static random access memory (SRAMnd)] thermal neutron detector exposed ex-phantom. A newly miniaturized, quick, and reliable active thermal neutron detector (TNRD, Thermal Neutron Rate Detector) was validated for both procedures. This first miniaturized active system eliminates the long postprocessing, required for passive detectors, giving thermal neutron fluences in real time. Methods: To validate TNRD for the established methodology, intrinsic characteristics, characterization of 4 facilities [to correlate monitor value (MU) with risk], and a cohort of 200 real patients (for second cancer risk estimates) were evaluated and compared with the well-established SRAMnd device. Finally, TNRD was compared to TLD pairs for 3 generic radiotherapy treatments through 16 strategic points inside an anthropomorphic phantom. Results: The performed tests indicate similar linear dependence with dose for both detectors, TNRD and SRAMnd, while a slightly better reproducibility has been obtained for TNRD (1.7% vs 2.2%). Risk estimates when delivering 1000 MU are in good agreement between both detectors (mean deviation of TNRD measurements with respect to the ones of SRAMnd is 0.07 cases per 1000, with differences always smaller than 0.08 cases per 1000). As far as the in-phantom measurements are concerned, a mean deviation smaller than 1.7% was obtained. Conclusions: The results obtained indicate that direct evaluation of equivalent dose estimation in organs, both in phantom and patients, is perfectly feasible with this new detector. This will open the door to an

  1. Equivalence in Dose Fall-Off for Isocentric and Nonisocentric Intracranial Treatment Modalities and Its Impact on Dose Fractionation Schemes

    International Nuclear Information System (INIS)

    Ma Lijun; Sahgal, Arjun; Descovich, Martina; Cho, Y.-B.; Chuang, Cynthia; Huang, Kim; Laperriere, Normand J.; Shrieve, Dennis C.; Larson, David A.

    2010-01-01

    Purpose: To investigate whether dose fall-off characteristics would be significantly different among intracranial radiosurgery modalities and the influence of these characteristics on fractionation schemes in terms of normal tissue sparing. Methods and Materials: An analytic model was developed to measure dose fall-off characteristics near the target independent of treatment modalities. Variations in the peripheral dose fall-off characteristics were then examined and compared for intracranial tumors treated with Gamma Knife, Cyberknife, or Novalis LINAC-based system. Equivalent uniform biologic effective dose (EUBED) for the normal brain tissue was calculated. Functional dependence of the normal brain EUBED on varying numbers of fractions (1 to 30) was studied for the three modalities. Results: The derived model fitted remarkably well for all the cases (R 2 > 0.99). No statistically significant differences in the dose fall-off relationships were found between the three modalities. Based on the extent of variations in the dose fall-off curves, normal brain EUBED was found to decrease with increasing number of fractions for the targets, with α/β ranging from 10 to 20. This decrease was most pronounced for hypofractionated treatments with fewer than 10 fractions. Additionally, EUBED was found to increase slightly with increasing number of fractions for targets with α/β ranging from 2 to 5. Conclusion: Nearly identical dose fall-off characteristics were found for the Gamma Knife, Cyberknife, and Novalis systems. Based on EUBED calculations, normal brain sparing was found to favor hypofractionated treatments for fast-growing tumors with α/β ranging from 10 to 20 and single fraction treatment for abnormal tissues with low α/β values such as α/β = 2.

  2. Spatial analysis of ambient gamma dose equivalent rate data by means of digital image processing techniques.

    Science.gov (United States)

    Szabó, Katalin Zsuzsanna; Jordan, Gyozo; Petrik, Attila; Horváth, Ákos; Szabó, Csaba

    2017-01-01

    A detailed ambient gamma dose equivalent rate mapping based on field measurements at ground level and at 1 m height was carried out at 142 sites in 80 × 90 km area in Pest County, Hungary. Detailed digital image processing analysis was carried out to identify and characterise spatial features such as outlying points, anomalous zones and linear edges in a smoothed TIN interpolated surface. The applied method proceeds from the simple shaded relief model and digital cross-sections to the more complex gradient magnitude and gradient direction maps, 2nd derivative profile curvature map, relief map and lineament density map. Each map is analysed for statistical characteristics and histogram-based image segmentation is used to delineate areas homogeneous with respect to the parameter values in these maps. Assessment of spatial anisotropy is implemented by 2D autocorrelogram and directional variogram analyses. The identified spatial features are related to underlying geological and tectonic conditions using GIS technology. Results show that detailed digital image processing is efficient in revealing the pattern present in field-measured ambient gamma dose equivalent rates and they are related to regional scale tectonic zones and surface sedimentary lithological conditions in the study area. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Individual monitoring of external exposure in terms of personal dose equivalent, Hp(d)

    International Nuclear Information System (INIS)

    Fantuzzi, E.

    2001-01-01

    The institute for Radiation Protection of ENEA - Bologna has organised a one day-workshop on the subject: Individual monitoring of external exposure in terms of personal dose equivalent, H p (d). The aim of the workshop was the discussion of the new implications and modifications to be expected in the routine individual monitoring of external radiation, due to the issue of the Decree 241/00 (G.U. 31/8/2000) in charge since 01/01/2001. The decree set up in Italian law the standards contained in the European Directive EURATOM 96/29-Basic Standards for the Protection of Health of Workers and the General Public against Dangers arising from Ionizing Radiation. Among others, the definition of the operational quantities for external radiation for personal and environmental monitoring, H p (d) e H * (d) respectively as defined by ICRU (International Commission for Radiation Units and Measurements), requires to update the methods of measurements and calibration of the personal dosemeters and environmental monitors. This report collects the papers presented at the workshop dealing with the Personal Dose Equivalent, H p (d), the conversion coefficients, H p (d)/K a e H p (d)/ , obtained through Monte Carlo calculations published by ICRU and ICRP (International Commission for Radiation Protection), the new calibration procedures and the practical implication in the routine of individual monitoring in terms of H p (d). Eventually, in the last chapter, the answers to Frequently Asked Questions (FAQ) are briefly reported [it

  4. Brachytherapy dose measurements in heterogeneous tissues

    Energy Technology Data Exchange (ETDEWEB)

    Paiva F, G.; Luvizotto, J.; Salles C, T.; Guimaraes A, P. C.; Dalledone S, P. de T.; Yoriyaz, H. [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Rubo, R., E-mail: gabrielpaivafonseca@gmail.com [Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, 05403-900 Sao Paulo (Brazil)

    2014-08-15

    Recently, Beau lieu et al. published an article providing guidance for Model-Based Dose Calculation Algorithms (MBDCAs), where tissue heterogeneity considerations are addressed. It is well-known that T G-43 formalism which considers only water medium is limited and significant dose differences have been found comparing both methodologies. The aim of the present work is to experimentally quantify dose values in heterogeneous medium using different dose measurement methods and techniques and compare them with those obtained with Monte Carlo simulations. Experiments have been performed using a Nucletron micro Selectron-Hdr Ir-192 brachytherapy source and a heterogeneous phantom composed by PMMA and different tissue equivalent cylinders like bone, lungs and muscle. Several dose measurements were obtained using tissue equivalent materials with height 1.8 cm and 4.3 cm positioned between the radiation source and the detectors. Radiochromic films, TLDs and MOSFET S have been used for the dose measurements. Film dosimetry has been performed using two methodologies: a) linearization for dose-response curve based on calibration curves to create a functional form that linearize s the dose response and b) 177 multichannel analysis dosimetry where the multiple color channels are analyzed allowing to address not only disturbances in the measurements caused by thickness variation in the film layer, but also, separate other external influences in the film response. All experiments have been simulated using the MCNP5 Monte Carlo radiation transport code. Comparison of experimental results are in good agreement with calculated dose values with differences less than 6% for almost all cases. (Author)

  5. Method to determine the position-dependant metal correction factor for dose-rate equivalent laser testing of semiconductor devices

    Science.gov (United States)

    Horn, Kevin M.

    2013-07-09

    A method reconstructs the charge collection from regions beneath opaque metallization of a semiconductor device, as determined from focused laser charge collection response images, and thereby derives a dose-rate dependent correction factor for subsequent broad-area, dose-rate equivalent, laser measurements. The position- and dose-rate dependencies of the charge-collection magnitude of the device are determined empirically and can be combined with a digital reconstruction methodology to derive an accurate metal-correction factor that permits subsequent absolute dose-rate response measurements to be derived from laser measurements alone. Broad-area laser dose-rate testing can thereby be used to accurately determine the peak transient current, dose-rate response of semiconductor devices to penetrating electron, gamma- and x-ray irradiation.

  6. Equivalent dose determination in foraminifera: analytical description of the CO{sub 2}{sup -}-signal dose-response curve

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, D. E-mail: dirk.hoffmann@iup.uni-heidelberg.de; Woda, C.; Mangini, A

    2003-02-01

    The dose-response of the CO{sub 2}{sup -}signal (g=2.0006) in foraminifera with ages between 19 and 300 ka is investigated. The sum of two exponential saturation functions is an adequate function to describe the dose-response curve up to an additional dose of 8000 Gy. It yields excellent dating results but requires an artificial doses of at least 5000 Gy. For small additional doses of about 500 Gy the single exponential saturation function can be used to calculate a reliable equivalent dose D{sub E}, although it does not describ the dose-response for higher doses. The CO{sub 2}{sup -}-signal dose-response indicates that the signal has two components of which one is less stable than the other.

  7. Total external dose equivalent and effective dose derived to the Piedmont population in the period 30 Apr 1986 - 22 Sep 1987

    International Nuclear Information System (INIS)

    Cortissone, C.; Giacomelli, R.; Spezzano, P.; Porzio, L.

    1988-01-01

    Some dosimetric evaluations concerning the population of the Piemonte Region, obtained after the measurements made following the Chernobyl accident, are reported. The individual effective mean dose equivalent derived from the exposure and intake in the period April 30, 1986 - September 22, 1987, is about 0.50 mSv

  8. The equivalent doses of indoor radon in some dwellings and enclosed areas in Morocco

    International Nuclear Information System (INIS)

    Hakam, O.; Choukri, J.; Reyss, L.

    2008-01-01

    Full text: The principal source of exposure to radiation for public in built-up areas is known to be the inhalation for radon its short-lived daughters.Most of this exposure occurs inside homes,where many hours are spent each day and where the volumic activity of radon is usually higher than outdoors. The compelling effects of radon and its short-lived decay products spread slowly but surely through a wide range of biological problems encountered in such areas as the mortality rates and lung cancer in uranium mines,the results of experimental work with animals, and the discovery of unsually high levels of radon in the living environments of the general population. As a way of prevention, we have measured the volumic activities of indoor radon-222 and we have calculated their effective equivalent dose in some dwellings and enclosed areas in Morocco. The obtained results show that the effective equivalent dose of activities measured indoor dwellings are inferior to the admissible annual limit fixed by ICRP for population, except in two twons situated in regions rich in phosphate deposits where the calculated doses are slightly upper than this limit. The results obtained for enclosed areas are inferior to the admissible annual limit fixed by ICRP for workers, except in the cave of geophysical observatory situated at depth of-12 meters where the obtained value don't present in risk for workers health because workers pass only a few minutes by day in this cave. The risks related to the volumic activities for indoor radon could be avoided by simple precautions such the continuous ventilation

  9. Comparison of the pharmacokinetics of tacrolimus and cyclosporine at equivalent molecular doses

    DEFF Research Database (Denmark)

    Karamperis, N; Povlsen, J V; Højskov, Carsten Schriver

    2003-01-01

    study was to compare single-dose pk profiles of the two drugs, following oral and intravenous administration, on the basis of equivalent molecular dosing, thus ruling out the quantitative factor. Five healthy volunteers and 14 dialysis patients (7 hemodialysis, 7 peritoneal dialysis) were included...

  10. Dose equivalent rate constants and barrier transmission data for nuclear medicine facility dose calculations and shielding design.

    Science.gov (United States)

    Kusano, Maggie; Caldwell, Curtis B

    2014-07-01

    A primary goal of nuclear medicine facility design is to keep public and worker radiation doses As Low As Reasonably Achievable (ALARA). To estimate dose and shielding requirements, one needs to know both the dose equivalent rate constants for soft tissue and barrier transmission factors (TFs) for all radionuclides of interest. Dose equivalent rate constants are most commonly calculated using published air kerma or exposure rate constants, while transmission factors are most commonly calculated using published tenth-value layers (TVLs). Values can be calculated more accurately using the radionuclide's photon emission spectrum and the physical properties of lead, concrete, and/or tissue at these energies. These calculations may be non-trivial due to the polyenergetic nature of the radionuclides used in nuclear medicine. In this paper, the effects of dose equivalent rate constant and transmission factor on nuclear medicine dose and shielding calculations are investigated, and new values based on up-to-date nuclear data and thresholds specific to nuclear medicine are proposed. To facilitate practical use, transmission curves were fitted to the three-parameter Archer equation. Finally, the results of this work were applied to the design of a sample nuclear medicine facility and compared to doses calculated using common methods to investigate the effects of these values on dose estimates and shielding decisions. Dose equivalent rate constants generally agreed well with those derived from the literature with the exception of those from NCRP 124. Depending on the situation, Archer fit TFs could be significantly more accurate than TVL-based TFs. These results were reflected in the sample shielding problem, with unshielded dose estimates agreeing well, with the exception of those based on NCRP 124, and Archer fit TFs providing a more accurate alternative to TVL TFs and a simpler alternative to full spectral-based calculations. The data provided by this paper should assist

  11. Alternatives to dose, quality factor and dose equivalent for low level irradiation

    International Nuclear Information System (INIS)

    Sondhaus, C.A.; Bond, V.P.; Feinendegen, L.E.

    1988-01-01

    Randomly occurring energy deposition events produced by low levels of ionizing radiation interacting with tissue deliver variable amounts of energy to the sensitive target volumes within a small fraction of the cell population. A model is described in which an experimentally derived function relating event size to cell response probability operates mathematically on the microdosimetric event size distribution characterizing a given irradiation and thus determines the total fractional number of responding cells; this fraction measures the effectiveness of the given radiation. Normalizing to equal numbers of events produced by different radiations and applying this cell response or hit size effectiveness function (HSEF) should define radiation quality, or relative effectiveness, on a more nearly absolute basis than do the absorbed dose and dose evaluation, which are confounded when applied to low level irradiations. Examples using both calculation and experimental data are presented. 15 refs., 18 figs

  12. Multilayer detector for skin absorbed dose measuring

    International Nuclear Information System (INIS)

    Osanov, D.P.; Panova, V.P.; Shaks, A.I.

    1985-01-01

    A method for skin dosimetry based on utilization of multilayer detectors and permitting to estimate distribution of absorbed dose by skin depth is described. The detector represents a set of thin sensitive elements separated by tissue-equivalent absorbers. Quantitative evaluation and forecasting the degree of radiation injury of skin are determined by the formula based on determination of the probability of the fact that cells are not destroyed and they can divide further on. The given method ensures a possibility of quantitative evaluation of radiobiological effect and forecasting clinical consequences of skin irradiation by results of corresponding measurements of dose by means of the miultilayer detector

  13. Investigation of real tissue water equivalent path lengths using an efficient dose extinction method

    Science.gov (United States)

    Zhang, Rongxiao; Baer, Esther; Jee, Kyung-Wook; Sharp, Gregory C.; Flanz, Jay; Lu, Hsiao-Ming

    2017-07-01

    For proton therapy, an accurate conversion of CT HU to relative stopping power (RSP) is essential. Validation of the conversion based on real tissue samples is more direct than the current practice solely based on tissue substitutes and can potentially address variations over the population. Based on a novel dose extinction method, we measured water equivalent path lengths (WEPL) on animal tissue samples to evaluate the accuracy of CT HU to RSP conversion and potential variations over a population. A broad proton beam delivered a spread out Bragg peak to the samples sandwiched between a water tank and a 2D ion-chamber detector. WEPLs of the samples were determined from the transmission dose profiles measured as a function of the water level in the tank. Tissue substitute inserts and Lucite blocks with known WEPLs were used to validate the accuracy. A large number of real tissue samples were measured. Variations of WEPL over different batches of tissue samples were also investigated. The measured WEPLs were compared with those computed from CT scans with the Stoichiometric calibration method. WEPLs were determined within  ±0.5% percentage deviation (% std/mean) and  ±0.5% error for most of the tissue surrogate inserts and the calibration blocks. For biological tissue samples, percentage deviations were within  ±0.3%. No considerable difference (extinction measurement took around 5 min to produce ~1000 WEPL values to be compared with calculations. This dose extinction system measures WEPL efficiently and accurately, which allows the validation of CT HU to RSP conversions based on the WEPL measured for a large number of samples and real tissues.

  14. Benefits of the effective dose equivalent concept at a medical center

    International Nuclear Information System (INIS)

    Vetter, R.J.; Classic, K.L.

    1991-01-01

    A primary objective of the recommendations of the International Committee on Radiological Protection Publication 26 is to insure that no source of radiation exposure is unjustified in relation to its benefits. This objective is consistent with goals of the Radiation Safety Committee and Institutional Review Board at medical centers where research may involve radiation exposure of human subjects. The effective dose equivalent concept facilitates evaluation of risk by those who have little or no knowledge of quantities or biological effects of radiation. This paper presents effective dose equivalent data used by radiation workers and those who evaluate human research protocols as these data relate to personal dosimeter reading, entrance skin exposure, and target organ dose. The benefits of using effective dose equivalent to evaluate risk of medical radiation environments and research protocols are also described

  15. Out-of-Field Dose Equivalents Delivered by Passively Scattered Therapeutic Proton Beams for Clinically Relevant Field Configurations

    International Nuclear Information System (INIS)

    Wroe, Andrew; Clasie, Ben; Kooy, Hanne; Flanz, Jay; Schulte, Reinhard; Rosenfeld, Anatoly

    2009-01-01

    Purpose: Microdosimetric measurements were performed at Massachusetts General Hospital, Boston, MA, to assess the dose equivalent external to passively delivered proton fields for various clinical treatment scenarios. Methods and Materials: Treatment fields evaluated included a prostate cancer field, cranial and spinal medulloblastoma fields, ocular melanoma field, and a field for an intracranial stereotactic treatment. Measurements were completed with patient-specific configurations of clinically relevant treatment settings using a silicon-on-insulator microdosimeter placed on the surface of and at various depths within a homogeneous Lucite phantom. The dose equivalent and average quality factor were assessed as a function of both lateral displacement from the treatment field edge and distance downstream of the beam's distal edge. Results: Dose-equivalent value range was 8.3-0.3 mSv/Gy (2.5-60-cm lateral displacement) for a typical prostate cancer field, 10.8-0.58 mSv/Gy (2.5-40-cm lateral displacement) for the cranial medulloblastoma field, 2.5-0.58 mSv/Gy (5-20-cm lateral displacement) for the spinal medulloblastoma field, and 0.5-0.08 mSv/Gy (2.5-10-cm lateral displacement) for the ocular melanoma field. Measurements of external field dose equivalent for the stereotactic field case showed differences as high as 50% depending on the modality of beam collimation. Average quality factors derived from this work ranged from 2-7, with the value dependent on the position within the phantom in relation to the primary beam. Conclusions: This work provides a valuable and clinically relevant comparison of the external field dose equivalents for various passively scattered proton treatment fields

  16. The equivalent dose comparison of different grain size quartz from lakeshore sediments in the arid region

    International Nuclear Information System (INIS)

    Fan Yuxin; Chen Fahu; Zhao Hui

    2009-01-01

    To investigate the feasibility of OSL dating of lakeshore sediments, equivalent dose (D e ) values of quartz fractions in different grain-size were measured using the 'Double-SAR' protocol of optical dating in four lakeshore sediments. There are two obvious different relations between D e values and grain sizes. The first situation is that the D e values are accordant with each other for fractions between 63 μm and 400 μm with a slightly decreasing tread of D e values as increasing of grain-size. The second situation is that the D e values are accordant to each other for fractions between 125 μm and 300 μm, while the D e values of the 63-90 μm fraction are obviously smaller than others. The first is consistent with those reported elsewhere, while the second can't be understood by the previous theory. (authors)

  17. Metoprolol Dose Equivalence in Adult Men and Women Based on Gender Differences: Pharmacokinetic Modeling and Simulations

    Directory of Open Access Journals (Sweden)

    Andy R. Eugene

    2016-11-01

    Full Text Available Recent meta-analyses and publications over the past 15 years have provided evidence showing there are considerable gender differences in the pharmacokinetics of metoprolol. Throughout this time, there have not been any research articles proposing a gender stratified dose-adjustment resulting in an equivalent total drug exposure. Metoprolol pharmacokinetic data was obtained from a previous publication. Data was modeled using nonlinear mixed effect modeling using the MONOLIX software package to quantify metoprolol concentration–time data. Gender-stratified dosing simulations were conducted to identify equivalent total drug exposure based on a 100 mg dose in adults. Based on the pharmacokinetic modeling and simulations, a 50 mg dose in adult women provides an approximately similar metoprolol drug exposure to a 100 mg dose in adult men.

  18. Quantifying the Combined Effect of Radiation Therapy and Hyperthermia in Terms of Equivalent Dose Distributions

    International Nuclear Information System (INIS)

    Kok, H. Petra; Crezee, Johannes; Franken, Nicolaas A.P.; Stalpers, Lukas J.A.; Barendsen, Gerrit W.; Bel, Arjan

    2014-01-01

    Purpose: To develop a method to quantify the therapeutic effect of radiosensitization by hyperthermia; to this end, a numerical method was proposed to convert radiation therapy dose distributions with hyperthermia to equivalent dose distributions without hyperthermia. Methods and Materials: Clinical intensity modulated radiation therapy plans were created for 15 prostate cancer cases. To simulate a clinically relevant heterogeneous temperature distribution, hyperthermia treatment planning was performed for heating with the AMC-8 system. The temperature-dependent parameters α (Gy −1 ) and β (Gy −2 ) of the linear–quadratic model for prostate cancer were estimated from the literature. No thermal enhancement was assumed for normal tissue. The intensity modulated radiation therapy plans and temperature distributions were exported to our in-house-developed radiation therapy treatment planning system, APlan, and equivalent dose distributions without hyperthermia were calculated voxel by voxel using the linear–quadratic model. Results: The planned average tumor temperatures T90, T50, and T10 in the planning target volume were 40.5°C, 41.6°C, and 42.4°C, respectively. The planned minimum, mean, and maximum radiation therapy doses were 62.9 Gy, 76.0 Gy, and 81.0 Gy, respectively. Adding hyperthermia yielded an equivalent dose distribution with an extended 95% isodose level. The equivalent minimum, mean, and maximum doses reflecting the radiosensitization by hyperthermia were 70.3 Gy, 86.3 Gy, and 93.6 Gy, respectively, for a linear increase of α with temperature. This can be considered similar to a dose escalation with a substantial increase in tumor control probability for high-risk prostate carcinoma. Conclusion: A model to quantify the effect of combined radiation therapy and hyperthermia in terms of equivalent dose distributions was presented. This model is particularly instructive to estimate the potential effects of interaction from different treatment

  19. Evaluation of effective dose equivalent on student's practice on intra-oral dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Wada, Shin-ichi; Hayama, Kazuhide; Toyama, Michio; Takase, Hiroshi (Nippon Dental Univ., Tokyo (Japan))

    1991-12-01

    We tried to discuss the problems on radiological protection of students in the practice of technique of intra-oral radiography with use of classmates. This radiographic practice has been performed after the technical training use of 'DXTTR' as a preclinical training. The practice was performed as training to take peri-apical, bite-wing, occlusal and eccentric projections. The mean film numbers which were used to complete those technique were 56 films. In these practice, dosimetries were performed on six locations of the body surface of every student who was taken radiograms using thermoluminescent dosimeters (TLD). The measured locations were orbit, bilateral submandible, neck, chest and abdomen. The effective dose equivalent was estimated using weighting factors of International Comission on Radiological Protection (ICRP) pub. 26 and the values of tissue dose equivalent obtained by TLD measurements. The results showed that the mean value of dose equivalent of each part was 5.40 mSv at orbit, 5.06 mSv at submandible, 0.75 mSv at neck, 0.04 mSv at chest and 0.02 mSv at abdomen. The maximum value of effective equivalent dose was 17.03 mSv which was lower than the dose equivalent limit for workers (50 mSv/year) recommended by ICRP pub. 26. The mean value of effective dose equivalent was 2.36 mSv. ICRP recommended the radiation protection for students aged 18 years or over that the procedures for restricting exposure should be broadly similar to those for occupational exposure. So the results indicate that those training was considered to be controlled in some reasonable level. The mean value of risk was estimated to be 3.94 x 10{sup -5}. Because intra-oral radiographic training with use of classmates is performed under extreme non-uniform irradiation, the evaluation of effective dose equivalent was considered to be important to control this special educational exposure and useful for optimization of the educational programs of radiographic technical training

  20. Measurement of extrapolation curves for the secondary pattern of beta radiation Nr. 86 calibrated in rapidity of absorbed dose for tissue equivalent by the Physikalisch Technische Bundesanstalt; Medicion de curvas de extrapolacion para el patron secundario de radiacion beta Nr. 86 calibrado en rapidez de dosis absorbida para tejido equivalente por el Physikalisch Technische Bundesanstalt

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T

    1988-10-15

    The following report has as objective to present the obtained results of measuring - with a camera of extrapolation of variable electrodes (CE) - the dose speed absorbed in equivalent fabric given by the group of sources of the secondary pattern of radiation Beta Nr. 86, (PSB), and to compare this results with those presented by the calibration certificates that accompany the PSB extended by the primary laboratory Physikalisch Technische Bundesanstalt, (PTB), of the R.F.A. as well as the uncertainties associated to the measure process. (Author)

  1. Neutron fluence-to-dose equivalent conversion factors: a comparison of data sets and interpolation methods

    International Nuclear Information System (INIS)

    Sims, C.S.; Killough, G.G.

    1983-01-01

    Various segments of the health physics community advocate the use of different sets of neutron fluence-to-dose equivalent conversion factors as a function of energy and different methods of interpolation between discrete points in those data sets. The major data sets and interpolation methods are used to calculate the spectrum average fluence-to-dose equivalent conversion factors for five spectra associated with the various shielded conditions of the Health Physics Research Reactor. The results obtained by use of the different data sets and interpolation methods are compared and discussed. (author)

  2. Evaluation of the equivalent dose rates due to neutrons emitted by plutonium oxide sources. Graphs

    International Nuclear Information System (INIS)

    Gouguet, Jackie.

    1975-06-01

    In irradiated fuel processing plants, the personnel concerned with radioprotection often require a rapid estimation of the equivalent dose rates due to neutrons emitted by plutonium oxide sources, sources having different physical and geometrical characteristics. Graphs are presented which facilitate rapid determinations. Graphs enabling the equivalent dose rates to be evaluated in contact with or at some distance from plutonium oxide sources of different geometrical characteristics are presented, the plutonium being obtained from fuels having been irradiated at different burn up in light water power reactors [fr

  3. Calculation of Ambient (H*(10)) and Personal (Hp(10)) Dose Equivalent from a 252Cf Neutron Source

    Energy Technology Data Exchange (ETDEWEB)

    Traub, Richard J.

    2010-03-26

    The purpose of this calculation is to calculate the neutron dose factors for the Sr-Cf-3000 neutron source that is located in the 318 low scatter room (LSR). The dose factors were based on the dose conversion factors published in ICRP-21 Appendix 6, and the Ambient dose equivalent (H*(10)) and Personal dose equivalent (Hp(10)) dose factors published in ICRP Publication 74.

  4. Limit groups, positive-genus towers and measure equivalence

    OpenAIRE

    Bridson, Martin R; Tweedale, Michael; Wilton, Henry

    2005-01-01

    By definition, an $\\omega$-residually free tower is positive-genus if all surfaces used in its construction are of positive genus. We prove that every limit group is virtually a subgroup of a positive-genus $\\omega$-residually free tower. By combining this with results of Gaboriau, we prove that elementarily free groups are measure equivalent to free groups.

  5. Annual dose equivalents estimation received by Cienfuegos population due medical practice

    International Nuclear Information System (INIS)

    Usagaua R, Z.; Santander I, E.

    1996-01-01

    This study represents the first evaluation of the effective equivalent dose that receives the population of the Cienfuegos province in Cuba because of medical practice. The evaluation is based on the tables of doses depending on several parameters that influence over these ones, and also based on large diagnostic examinations statistics of all medical institutions over a 9 years period. Values of examinations frequency, contribution to total dose from radiography, fluoroscopy, dental radiography and nuclear medicine, and other characteristics of the last ones are offered. A comparative reflection dealing with received doses by radiography and fluoroscopy techniques is also included. (authors). 4 refs

  6. Neutron equivalent doses and associated lifetime cancer incidence risks for head & neck and spinal proton therapy

    Science.gov (United States)

    Athar, Basit S.; Paganetti, Harald

    2009-08-01

    In this work we have simulated the absorbed equivalent doses to various organs distant to the field edge assuming proton therapy treatments of brain or spine lesions. We have used computational whole-body (gender-specific and age-dependent) voxel phantoms and considered six treatment fields with varying treatment volumes and depths. The maximum neutron equivalent dose to organs near the field edge was found to be approximately 8 mSv Gy-1. We were able to clearly demonstrate that organ-specific neutron equivalent doses are age (stature) dependent. For example, assuming an 8-year-old patient, the dose to brain from the spinal fields ranged from 0.04 to 0.10 mSv Gy-1, whereas the dose to the brain assuming a 9-month-old patient ranged from 0.5 to 1.0 mSv Gy-1. Further, as the field aperture opening increases, the secondary neutron equivalent dose caused by the treatment head decreases, while the secondary neutron equivalent dose caused by the patient itself increases. To interpret the dosimetric data, we analyzed second cancer incidence risks for various organs as a function of patient age and field size based on two risk models. The results show that, for example, in an 8-year-old female patient treated with a spinal proton therapy field, breasts, lungs and rectum have the highest radiation-induced lifetime cancer incidence risks. These are estimated to be 0.71%, 1.05% and 0.60%, respectively. For an 11-year-old male patient treated with a spinal field, bronchi and rectum show the highest risks of 0.32% and 0.43%, respectively. Risks for male and female patients increase as their age at treatment time decreases.

  7. Personal dose equivalent conversion coefficients for electrons to 1 Ge V.

    Science.gov (United States)

    Veinot, K G; Hertel, N E

    2012-04-01

    In a previous paper, conversion coefficients for the personal dose equivalent, H(p)(d), for photons were reported. This note reports values for electrons calculated using similar techniques. The personal dose equivalent is the quantity used to approximate the protection quantity effective dose when performing personal dosemeter calibrations and in practice the personal dose equivalent is determined using a 30×30×15 cm slab-type phantom. Conversion coefficients to 1 GeV have been calculated for H(p)(10), H(p)(3) and H(p)(0.07) in the recommended slab phantom. Although the conversion coefficients were determined for discrete incident energies, analytical fits of the conversion coefficients over the energy range are provided using a similar formulation as in the photon results previously reported. The conversion coefficients for the personal dose equivalent are compared with the appropriate protection quantity, calculated according to the recommendations of the latest International Commission on Radiological Protection guidance. Effects of eyewear on H(p)(3) are also discussed.

  8. Additional effective dose equivalent for adults and children in Poland as the result of mushroom consumption

    International Nuclear Information System (INIS)

    Jasinska, H.; Kozak, K.; Mietelski, J.W.

    2004-01-01

    Experimental data of caesium radioactivity in samples of various mushrooms collected all over Poland from 1986 to 1989 are presented. Nearly 80 samples from Poland and a few samples from Austria and USSR were analysed. The effective dose equivalents for adults and children caused by the consumption of one mass unit of dried mushrooms for each sample were estimated. (author)

  9. Evaluation of the effective dose equivalent to tbe public of Pavia after the Chernobyl nuclear accident

    International Nuclear Information System (INIS)

    Altieri, S.; Berzero, A.; Meloni, S.; Rosti, G.; Genova, N.

    1988-01-01

    The Chernobyl radionuclide monitoring campaign in air particulate and foodstuffs was carried out and continued up to June 1987. On the basis of collected data estimates of the collective effective dose equivalent commitment to the public of province of Pavia, by external irradiation or by inhalation, were carried out and are reported in the present paper

  10. Dependence on age at intake of committed dose equivalents from radionuclides

    International Nuclear Information System (INIS)

    Adams, N.

    1981-01-01

    The dependence of committed dose equivalents on age at intake is needed to assess the significance of exposures of young persons among the general public resulting from inhaled or ingested radionuclides. The committed dose equivalents, evaluated using ICRP principles, depend on the body dimensions of the young person at the time of intake of a radionuclide and on subsequent body growth. Representation of growth by a series of exponential segments facilitates the derivation of general expressions for the age dependence of committed dose equivalents if metabolic models do not change with age. The additional assumption that intakes of radionuclides in air or food are proportional to a person's energy expenditure (implying age-independent dietary composition) enables the demonstration that the age of the most highly exposed 'critical groups' of the general public from these radionuclides is either about 1 year or 17 years. With the above assumptions the exposure of the critical group is less than three times the exposure of adult members of the general public. Approximate values of committed dose equivalents which avoid both underestimation and excessive overestimation are shown to be obtainable by simplified procedures. Modified procedures are suggested for use if metabolic models change with age. (author)

  11. Equivalent dose, effective dose and risk assessment from panoramic radiography to the critical organs of head and neck region

    International Nuclear Information System (INIS)

    Cho, Bong Hae; Nah, Kyung Soo; Lee, Ae Ryeon

    1995-01-01

    The purpose of this study was to evaluate the equivalent and effective dose, and estimate radiation risk to the critical organs of head and neck region from the use of adult and child mode in panoramic radiography. The results were as follows. 1. The salivary glands showed the highest equivalent and effective dose in adult and child mode. The equivalent and effective dose in adult mode were 837 μSv and 20.93 μSv, those in child mode were 462 μSv and 11.54 μSv, respectively. 2. Total effective doses to the critical head and neck organs were estimated 34.2l μSv in adult mode, 20.14 μSv in child mode. From these data, the probabilities of stochastic effect from adult and child mode were 2.50xl0 -6 and 1.47x10 -6 3. The other remainder showed the greatest risk of fatal cancer. The risk estimate were 4.5 and 2.7 fatal malignancies in adult and child mode from million examinations. The bone marrow and thyroid gland showed about 0.1 fatal cancer in adult. and child mode from these examinations.

  12. Equivalent dose, effective dose and risk assessment from panoramic radiography to the critical organs of head and neck region

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Bong Hae; Nah, Kyung Soo [Dept. of Dental Radiology, College of Dentistry, Pusan National University, Pusan (Korea, Republic of); Lee, Ae Ryeon [Dept. of Pediatric Dentistry, College of Dentistry, Pusan National University, Pusan (Korea, Republic of)

    1995-08-15

    The purpose of this study was to evaluate the equivalent and effective dose, and estimate radiation risk to the critical organs of head and neck region from the use of adult and child mode in panoramic radiography. The results were as follows. 1. The salivary glands showed the highest equivalent and effective dose in adult and child mode. The equivalent and effective dose in adult mode were 837 {mu}Sv and 20.93 {mu}Sv, those in child mode were 462 {mu}Sv and 11.54 {mu}Sv, respectively. 2. Total effective doses to the critical head and neck organs were estimated 34.2l {mu}Sv in adult mode, 20.14 {mu}Sv in child mode. From these data, the probabilities of stochastic effect from adult and child mode were 2.50xl0{sup -6} and 1.47x10{sup -6} 3. The other remainder showed the greatest risk of fatal cancer. The risk estimate were 4.5 and 2.7 fatal malignancies in adult and child mode from million examinations. The bone marrow and thyroid gland showed about 0.1 fatal cancer in adult. and child mode from these examinations.

  13. Equivalent dose estimation using a single aliquot of polymineral fine grains

    DEFF Research Database (Denmark)

    Banerjee, D.; Murray, A.S.; Bøtter-Jensen, L.

    2001-01-01

    We have tested the suitability of a new single-aliquot regenerative-dose protocol for estimating the equivalent dose (D-e) in polymineral fine grains extracted from colluvia from various sites in Germany. First, we report the behaviour of three OSL signals: (i) blue-stimulated, (ii) infrared......C, the post-IR blue signals are stable. The preheat dependence of estimates of D-e obtained using fine grains is presented for the first time, for both blue- and IR-derived signals. Our results are compared with D-e estimates derived from multiple-aliquot additive-dose IR luminescence data, obtained using...

  14. Semi-empirical equivalent field method for dose determination in midline block fields for cobalt - 60 beam

    International Nuclear Information System (INIS)

    Tagoe, S.N.A.; Nani, E.K.; Yarney, J.; Edusa, C.; Quayson-Sackey, K.; Nyamadi, K.M.; Sasu, E.

    2012-01-01

    For teletherapy treatment time calculations, midline block fields are resolved into two fields, but neglecting scattering from other fields, the effective equivalent square field size of the midline block is assumed to the resultant field. Such approach is underestimation, and may be detrimental in achieving the recommended uncertainty of ± 5 % for patient's radiation dose delivery. By comparison, the deviations of effective equivalent square field sizes by calculations and experiments were within 13.2 % for cobalt 60 beams of GWGP80 cobalt 60 teletherapy. Therefore, a modified method incorporating the scatter contributions was adopted to estimate the effective equivalent square field size for midline block field. The measured outputs of radiation beams with the block were compared with outputs of square fields without the blocks (only the block tray) at depths of 5 and 10 cm for the teletherapy machine employing isocentric technique, and the accuracy was within ± 3 % for the cobalt 60 beams. (au)

  15. Assessment of individual dose equivalents Hp(0.07) of medical staff occupationally exposed to ionizing radiation in 2012.

    Science.gov (United States)

    Papierz, Sylwia; Kamiński, Zbigniew; Adamowicz, Małgorzata; Zmyślony, Marek

    2014-01-01

    The paper presents the Nofer Institutes of Occupational Medicine in Łódź's results of the assessment of individual dose equivalents Hp(0.07) of medical staff exposed to X-rays in Poland in 2012. In addition, the collected data was analysed in terms of types of medical units performing medical procedures and the categorization of personnel. Dosimetric service was provided for medical staff of interventional radiology departments occupationally exposed to ionizing radiation in terms of individual dose equivalents Hp(0.07). In 2012, personal dosimetry Hp(0.07) determinations were performed by the Nofer Institute of Occupational Medicine in Łódź and covered 2044 employees from 174 health facilities. The determinations were performed using thermoluminescence dosimetry according to the procedure accredited by the Polish Centre for Accreditation (document number AB 327). The measurements were performed using ring-dosimeters in the periods of 1 or 2 months. Mean annual individual dose equivalent Hp(0.07) in 2012 was equal to 3.3 mSv (annual limit for Hp(0.07) is 500 mSv). The average value of annual individual dose equivalent Hp(0.07) decreased comparing to the previous year. In 2012, no single case of exceeding the annual limit for Hp(0.07) was reported. Data stored in the file indicates that more than 96% of all of the annual doses did not exceed the level of 10 mSv. The analysis of data on occupational exposure to ionizing radiation confirms a stable level of exposure and satisfactory radiological protection in interventional radiology facilities monitored by the Nofer Institute of Occupational Medicine in Łódź in Poland in 2012.

  16. Calculation of the individual effective dose equivalent in Italy following the Chernobyl accident

    International Nuclear Information System (INIS)

    Lotfi, M.; Mancioppi, S.; Piermattei, S.; Tommasino, L.; Azimi-Garakani, D.

    1991-01-01

    Estimates are presented here for the individual effective dose equivalents (EDE) from dietary intake of radiocaesium-contaminated food by the average Italian consumer in different age groups. Food items of consumption rate greater than 50kg/y were included in the food basket studies. In view of the pattern of food consumption in Italy, the radiocaesium concentrations of foodstuffs such as milk, milk products, bread, pasta, meat fruit, vegetables and babyfoods were measured between January 1987 and December 1988 inclusive. These measurements were carried out mainly by the environmental radioactivity laboratories in three administrative districts of Italy. The results show that the total individual EDE values received in 1987 from foodstuffs were around 175, 110 and 70 μSv/year for adults, children (up to 10 years old) and infants (up to one year old), respectively. The corresponding values for 1988 are about 15, 10 and 20 μSv/year, respectively. The EDE committed in the latter half relative to the first half of 1987 was a factor of 2.5 and 3 less for adults and children, respectively, and a factor of about 2 for infants. In 1988, no significant change was observed in EDE values during the year. (author)

  17. Proposed dose equivalence between clonazepam and pramipexole in patients with restless legs syndrome.

    Science.gov (United States)

    Shinno, Hideto; Oka, Yasunori; Otsuki, Manabu; Tsuchiya, Satoshi; Mizuno, Soichi; Kawada, Seiichi; Innami, Toshihiko; Sasaki, Akira; Hineno, Takashi; Sakamoto, Tetsuro; Inami, Yasushi; Nakamura, Yu; Horiguchi, Jun

    2010-04-16

    Dopamine agonists are accepted as the first-line medications for restless legs syndrome (RLS). In some Asian countries, clonazepam is one of the prevalent medications for RLS because of its effect on sleep disturbances. To date, there have not been any studies that examined equivalent doses of pramipexole and clonazepam. To evaluate equivalent doses of pramipexole and clonazepam in RLS, we investigated the efficacy and tolerability after conversion from clonazepam to pramipexole, and examined dose equivalence between the two prescriptions. In a prospective, open-label, multicenter study, 26 RLS patients treated with clonazepam (mean age: 69.2+/-11.0years old) were enrolled and then rapidly switched to pramipexole using a conversion calculation of 4:1 for daily doses. Then the daily dose of pramipexole was up titrated or tapered by 0.125mg/day at each subsequent examination. RLS symptoms and daytime somnolence were evaluated using the International RLS Study Group rating scale (IRLS), Clinical Global Impressions - Severity of illness (CGI-S) and the Epworth Sleepiness Scale (ESS), respectively. Conversion from clonazepam to pramipexole resulted in significant reductions of IRLS (16.3+/-8.7 to 9.1+/-6.3) and ESS (6.5+/-4.2 to 4.4+/-3.2). CGI scores demonstrated improvement after conversion. In 4 patients (15%), adverse events such as somnolence, sensation of oppression in the lower limbs, diarrhea, or nausea were present. Correlation analysis demonstrated a significant relationship between these daily doses. Spearman's correlation coefficient was 0.662. Our study, however, has some limitations since it is an open-label trial and includes only 26 patients. Further studies using a double-blind design or a crossover design are recommended. Statistical analysis demonstrated a 4:1 conversion for clonazepam to pramipexole. When switchover from clonazepam to pramipexole is done, this conversion ratio may be helpful to determine the initial dose of pramipexole for treating

  18. Dose of radiation enhancement, using silver nanoparticles in a human tissue equivalent gel dosimeter.

    Science.gov (United States)

    Hassan, Muhammad; Waheed, Muhammad Mohsin; Anjum, Muhammad Naeem

    2016-01-01

    To quantify the radiation dose enhancement in a human tissue-equivalent polymer gel impregnated with silver nanoparticles. The case-control study was conducted at the Bahawalpur Institute of Nuclear Medicine and Oncology, Bahawalpur, Pakistan, in January 2014. Silver nanoparticles used in this study were prepared by wet chemical method. Polymer gel was prepared by known quantity of gelatine, methacrylic acid, ascorbic acid, copper sulphate pentahydrate, hydroquinone and water. Different concentrations of silver nanoparticles were added to the gel during its cooling process. The gel was cooled in six plastic vials of 50ml each. Two vials were used as a control sample while four vials were impregnated with silver nanoparticles. After 22 hours, the vials were irradiated with gamma rays by aCobalt-60 unit. Radiation enhancement was assessed by taking magnetic resonance images of the vials. The images were analysed using Image J software. The dose enhancement factor was 24.17% and 40.49% for 5Gy and 10Gy dose respectively. The dose enhancement factor for the gel impregnated with 0.10mM silver nanoparticles was 32.88% and 51.98% for 5Gy and 10Gy dose respectively. The impregnation of a tissue-equivalent gel with silver nanoparticles resulted in dose enhancement and this effect was magnified up to a certain level with the increase in concentration of silver nanoparticles.

  19. Dose equivalents of antidepressants: Evidence-based recommendations from randomized controlled trials.

    Science.gov (United States)

    Hayasaka, Yu; Purgato, Marianna; Magni, Laura R; Ogawa, Yusuke; Takeshima, Nozomi; Cipriani, Andrea; Barbui, Corrado; Leucht, Stefan; Furukawa, Toshi A

    2015-07-15

    Dose equivalence of antidepressants is critically important for clinical practice and for research. There are several methods to define and calculate dose equivalence but for antidepressants, only daily defined dose and consensus methods have been applied to date. The purpose of the present study is to examine dose equivalence of antidepressants by a less arbitrary and more systematic method. We used data from all randomized, double-blind, flexible-dose trials comparing fluoxetine or paroxetine as standard drugs with any other active antidepressants as monotherapy in the acute phase treatment of unipolar depression. We calculated the ratio of the mean doses for each study and weighted it by the total sample size to find the weighted mean ratio for each drug, which was then used to define the drug׳s dosage equivalent to fluoxetine 40mg/d. We included 83 studies (14 131 participants). In the primary analysis, fluoxetine 40mg/day was equivalent to paroxetine dosage of 34.0mg/day, agomelatine 53.2mg/day, amitriptyline, 122.3mg/day, bupropion 348.5mg/day, clomipramine 116.1mg/day, desipramine 196.3mg/day, dothiepin 154.8mg/day, doxepin 140.1mg/day, escitalopram 18.0mg/day, fluvoxamine 143.3mg/day, imipramine 137.2mg/day, lofepramine 250.2mg/day, maprotiline 118.0mg/day, mianserin, 101.1mg/day, mirtazapine 50.9mg/day, moclobemide 575.2mg/day, nefazodone 535.2mg/day, nortriptyline 100.9mg/day, reboxetine 11.5mg/day, sertraline 98.5mg/day, trazodone 401.4mg/day, and venlafaxine 149.4mg/day. Sensitivity analyses corroborated the results except for doxepin. The number of studies for some drugs was small. The current method assumes dose response relationship of antidepressants. Our findings can be useful for clinicians when they switch antidepressants and for researchers when they compare various antidepressants in their research. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Development of prediction system of dose equivalent rate around a package

    International Nuclear Information System (INIS)

    Nakao, Tetsuya; Minakami, Goro; Taniuchi, Hiroaki; Fujisawa, Kyosuke; Matsukawa, Yukio; Mimura, Shigemi.

    1993-01-01

    A new system is developed that can evaluate the radiation strength of the source in detail, on the basis of the irradiation history of each fuel assembly in a TN-12 or 12A package, and then to determine the best way to organize the assemblies in the package so that the dose equivalent rate around a package is kept to a minimum. This system for minimizing the danger of radiation for operators involved in packaging and transporting spent fuel was developed for personal computer use, to offer ease in handling and high adaptability. The data input is done in dialogue style, with a variety of check functions. In checks to verify the accuracy of the shielding calculation data in this system by comparing the calculated values with several kinds of measured values, the reliability of this new system has been shown to be very high. Since its high utility has been recognized, the system has already been put into use in actual transportation situations. (J.P.N.)

  1. A computer program to calculate the committed dose equivalent after the inhalation of radioactivity

    International Nuclear Information System (INIS)

    Van der Woude, S.

    1989-03-01

    A growing number of people are, as part of their occupation, at risk of being exposed to radiation originating from sources inside their bodies. The quantification of this exposure is an important part of health physics. The International Commission on Radiological Protection (ICRP) developed a first-order kinetics compartmental model to determine the transport of radioactive material through the human body. The model and the parameters involved in its use, are discussed. A versatile computer program was developed to do the following after the in vivo measurement of either the organ- or whole-body activity: calculate the original amount of radioactive material which was inhaled (intake) by employing the ICRP compartmental model of the human body; compare this intake to calculated reference levels and state any action to be taken for the case under consideration; calculate the committed dose equivalent resulting from this intake. In the execution of the above-mentioned calculations, the computer program makes provision for different aerosol particle sizes and the effect of previous intakes. Model parameters can easily be changed to take the effects of, for instance, medical intervention into account. The computer program and the organization of the data in the input files are such that the computer program can be applied to any first-order kinetics compartmental model. The computer program can also conveniently be used for research on problems related to the application of the ICRP model. 18 refs., 25 figs., 5 tabs

  2. Mapping of isoexposure curves for evaluation of equivalent environmental doses for radiodiagnostic mobile equipment

    International Nuclear Information System (INIS)

    Bacelar, Alexandre; Andrade, Jose Rodrigo Mendes; Fischer, Andreia Caroline Fischer da Silveira; Accurso, Andre; Hoff, Gabriela

    2011-01-01

    This paper generates iso exposure curves in areas where the mobile radiodiagnostic equipment are used for evaluation of iso kerma map and the environment equivalent dose (H * (d)). It was used a Shimadzu mobile equipment and two Siemens, with non anthropomorphic scatter. The exposure was measured in a mesh of 4.20 x 4.20 square meter in steps of 30 cm, at half height from the scatterer. The calculation of H * (d) were estimated for a worker present in all the procedures in a period of 11 months, being considered 3.55 m As/examination and 44.5 procedures/month (adult UTI) and 3.16 m As/examination and 20.1 procedure/month (pediatric UTI), and 3.16 m As/examination and 20.1 procedure/month (pediatric UTI). It was observed that there exist points where the H * (d) was over the limit established for the free area inside the radius of 30 cm from the central beam of radiation in the case of pediatric UTI and 60 cm for adult UTI. The points localized 2.1 m from the center presented values lower than 25% of those limit

  3. The meaning and the principle of determination of the effective dose equivalent in radiation protection

    International Nuclear Information System (INIS)

    Drexler, G.; Williams, G.; Zankl, M.

    1985-01-01

    Since the introduction of the quantity ''effective dose equivalent'' within the framework of new radiation concepts, the meaning and interpretation of the quantity is often discussed and debated. Because of its adoption as a limiting quantity in many international and national laws, it is necessary to be able to interpret this main radiation protection quantity. Examples of organ doses and the related Hsub(E) values in occupational and medical exposures are presented and the meaning of the quantity is considered for whole body exposures to external and internal photon sources, as well as for partial body external exposures to photons. (author)

  4. Isotope determinations of renal clearance equivalent with physiological clearance measurements

    International Nuclear Information System (INIS)

    Junges, R.

    1983-01-01

    The concept of renal clearance in nuclear medicine describes the tubular secretion and glomerular filtration of a substance being removed from the blood plasma. The concept of clearance as used physiologically is rather wider and includes consideration of the outflow of the substances remained back in the kidneys. The present paper discusses clearance measurements as seen from a thermodynamic point of view, in which isotope clearances become equivalent with the physiological concept of clearance. In addition, it is possible to quantify each single step of the excretory function of each kidney separately. (orig.) [de

  5. Determination of eye lenses dose equivalent in terms of Hp(3)

    International Nuclear Information System (INIS)

    Klamert, V.; Caresana, M.; Minchillo, G.; Tambussi, O.

    2002-01-01

    The Italian radioprotection legislation requires the determination of personal dose equivalent in terms of H p (10) and H p (0.07) and the determination of the eye lenses dose equivalent in terms of H p (3). Whereas the calibration of a dosemeter for the determination of H p (10) and H p (0.07) is feasible, the calibration of a dosemeter in terms of H p (3) is impossible, owing to the absence of the suitable phantom and the conversion coefficients h pk (3) from air kerma to H p (3). Using an anthropomorphic phantom for the irradiation, the aim of this work is to determine the experimental values of the conversion coefficients and to relate the result of the dosemeter worn on the forehead with the dose equivalent to the eye lenses. The study is performed in the X energy range from 30 keV to 100 keV, i.e. the one most widely used in medical practices

  6. Using two detectors concurrently to monitor ambient dose equivalent rates in vehicle surveys of radiocesium contaminated land.

    Science.gov (United States)

    Takeishi, Minoru; Shibamichi, Masaru; Malins, Alex; Kurikami, Hiroshi; Murakami, Mitsuhiro; Saegusa, Jun; Yoneya, Masayuki

    2017-10-01

    In response to the accident at Tokyo Electric Power Company's Fukushima Dai-ichi Nuclear Power Plant (FDNPP), vehicle-borne monitoring was used to map radiation levels for radiological protection of the public. By convention measurements from vehicle-borne surveys are converted to the ambient dose equivalent rate at 1 m height in the absence of the vehicle. This allows for comparison with results from other types of survey, including surveys with hand-held or airborne instruments. To improve the accuracy of the converted results from vehicle-borne surveys, we investigated combining measurements from two detectors mounted on the vehicle at different heights above the ground. A dual-detector setup was added to a JAEA monitoring car and compared against hand-held survey meter measurements in Fukushima Prefecture. The results obtained by combining measurements from two detectors were within ±20% of the hand-held reference measurements. The mean absolute percentage deviation from the reference measurements was 7.2%. The combined results from the two detectors were more accurate than those from either the roof-mounted detector, or the detector inside the vehicle, taken alone. One issue with vehicle-borne surveys is that ambient dose equivalent rates above roads are not necessarily representative of adjacent areas. This is because radiocesium is often deficient on asphalt surfaces, as it is easily scrubbed off by rain, wind and vehicle tires. To tackle this issue, we investigated mounting heights for vehicle-borne detectors using Monte Carlo gamma-ray simulations. When radiocesium is deficient on a road compared to the adjacent land, mounting detectors high on vehicles yields results closer to the values adjacent to the road. The ratio of ambient dose equivalent rates reported by detectors mounted at different heights in a dual-detector setup indicates whether radiocesium is deficient on the road compared to the adjacent land. Copyright © 2017 Elsevier Ltd. All rights

  7. Preliminary On-Orbit Neutron Dose Equivalent and Energy Spectrum Results from the ISS-RAD Fast Neutron Detector (FND)

    Science.gov (United States)

    Semones, Edward; Leitgab, Martin

    2016-01-01

    The ISS-RAD instrument was activated on ISS on February 1st, 2016. Integrated in ISS-RAD, the Fast Neutron Detector (FND) performs, for the first time on ISS, routine and precise direct neutron measurements between 0.5 and 8 MeV. Preliminary results for neutron dose equivalent and neutron flux energy distributions from online/on-board algorithms and offline ground analyses will be shown, along with comparisons to simulated data and previously measured neutron spectral data. On-orbit data quality and pre-launch analysis validation results will be discussed as well.

  8. Improvement of the equivalent sphere model for better estimates of skin or eye dose in space radiation environments

    International Nuclear Information System (INIS)

    Lin, Z.W.

    2011-01-01

    It is often useful to get a quick estimate of the dose or dose equivalent of an organ, such as blood-forming organs, the eye or the skin, in a radiation field. Sometimes an equivalent sphere is used to represent the organ for this purpose. For space radiation environments, recently it has been shown that the equivalent sphere model does not work for the eye or the skin in solar particle event environments. In this study, we improve the representation of the eye and the skin using a two-component equivalent sphere model. Motivated by the two-peak structure of the body organ shielding distribution for the eye and the skin, we use an equivalent sphere with two radius parameters, for example a partial spherical shell of a smaller thickness over a proper fraction of the full solid angle combined with a concentric partial spherical shell of a larger thickness over the rest of the full solid angle, to represent the eye or the skin. We find that using an equivalent sphere with two radius parameters instead of one drastically improves the accuracy of the estimates of dose and dose equivalent in space radiation environments. For example, in solar particle event environments the average error in the estimate of the skin dose equivalent using an equivalent sphere with two radius parameters is about 8%, while the average error of the conventional equivalent sphere model using one radius parameter is around 100%.

  9. Interdevice agreement of eight equivalent dental color measurement devices.

    Science.gov (United States)

    Weyhrauch, M; Igiel, C; Pabst, A M; Wentaschek, S; Scheller, H; Lehmann, K M

    2015-12-01

    The reproducibility of electronic color-measuring devices used in dentistry refers to the consistency of measurements of a single device and also that between identical devices. This in vitro study evaluated the short-term interdevice agreement of eight equivalent dental measurement devices. The short-term repeatability of eight identical VITA Easyshade Advance color measurement devices was evaluated. Each device was used to quantify the Commission Internationale de l'Eclairage (CIE) L*a*b* color coordinates of ceramic disks, designed in accordance with guidelines set by the VITA Toothguide 3D-Master shade tab organization. Statistical analysis involved calculating the intraclass correlation coefficients (ICCs) and color differences (ΔE*) for corresponding measurements taken by the devices. In addition, the mean color difference from the mean (MCDM) was calculated for each color. All devices showed high ICCs for the color coordinates (L = 0.996, a = 0.993, b = 0.999). The ΔE* by shade ranged from 0.62 to 1.67. The MCDM by color-measuring device ranged from 0.11 to 0.23. This in vitro study showed that the color-measuring devices used were suitable for determining shade with high repeatability. The high interdevice agreement of the VITA Easyshade Advance means that dental professionals can use this device independently, without compromising the consistency and quality of color measurements.

  10. No-Signalling Is Equivalent To Free Choice of Measurements

    Directory of Open Access Journals (Sweden)

    Samson Abramsky

    2014-12-01

    Full Text Available No-Signalling is a fundamental constraint on the probabilistic predictions made by physical theories. It is usually justified in terms of the constraints imposed by special relativity. However, this justification is not as clear-cut as is usually supposed. We shall give a different perspective on this condition by showing an equivalence between No-Signalling and Lambda Independence, or "free choice of measurements", a condition on hidden-variable theories which is needed to make no-go theorems such as Bell's theorem non-trivial. More precisely, we shall show that a probability table describing measurement outcomes is No-Signalling if and only if it can be realized by a Lambda-Independent hidden-variable theory of a particular canonical form, in which the hidden variables correspond to non-contextual deterministic predictions of measurement outcomes. The key proviso which avoids contradiction with Bell's theorem is that we consider hidden-variable theories with signed probability measures over the hidden variables - i.e. negative probabilities. Negative probabilities have often been discussed in the literature on quantum mechanics. We use a result proved previously in "The Sheaf-theoretic Structure of Locality and Contextuality" by Abramsky and Brandenburger, which shows that they give rise to, and indeed characterize, the entire class of No-Signalling behaviours. In the present paper, we put this result in a broader context, which reveals the surprising consequence that the No-Signalling condition is equivalent to the apparently completely different notion of free choice of measurements.

  11. Biological equivalence of low dose rate to multifractionated high dose rate irradiations: investigations in mouse lip mucosa

    International Nuclear Information System (INIS)

    Stueben, Georg; Kogel, Albert J. van der; Schueren, Emmanuel van der

    1997-01-01

    Background and purpose: The aim of this study was to evaluate the biological equivalence of continuous low dose rate (LDR) irradiations to multifractionated high dose rate (HDR) regimes. The applicability of the LQ model was analysed for fraction sizes and dose rates relevant for the clinic. Material and methods: Investigations were performed in mouse lip mucosa. HDR fractions were given in an overall treatment time ranging from 10 h to 3.5 days. The dose rate effect was analysed in the range of 84 to 0.76 Gy/h. For an assessment of biological equivalence in comparison to LDR, HDR irradiations have been performed in the same overall treatment time as the corresponding LDR regimes. Results: Recovery leads to sparing of radiation damage as the dose rate is reduced from 84 to 0.76 Gy/h (20.0 versus 45.7 Gy ED 50 ). No significant additional sparing from 0.9 to 0.76 Gy/h could be demonstrated (44.9 versus 45.7 Gy ED 50 ). Even 30 HDR fractions in 24 h were not sufficient to match the effect of LDR over the same time period (38.2 versus 41.1 Gy ED 50 ). The present data give evidence for a bi-exponential repair process in mouse lip mucosa (T 1/2fast 27 min, T 1/2slow 150 min). Repair is dominated by the faster component (>80%). Conclusions: LDR is the most efficient way to deliver radiation if recovery is to be maximised and the overall time kept as short as possible. When used with realistic parameters the LQ model is capable of providing quantitative guidelines in areas of clinical interest

  12. Emphysema quantification and lung volumetry in chest X-ray equivalent ultralow dose CT - Intra-individual comparison with standard dose CT.

    Science.gov (United States)

    Messerli, Michael; Ottilinger, Thorsten; Warschkow, René; Leschka, Sebastian; Alkadhi, Hatem; Wildermuth, Simon; Bauer, Ralf W

    2017-06-01

    To determine whether ultralow dose chest CT with tin filtration can be used for emphysema quantification and lung volumetry and to assess differences in emphysema measurements and lung volume between standard dose and ultralow dose CT scans using advanced modeled iterative reconstruction (ADMIRE). 84 consecutive patients from a prospective, IRB-approved single-center study were included and underwent clinically indicated standard dose chest CT (1.7±0.6mSv) and additional single-energy ultralow dose CT (0.14±0.01mSv) at 100kV and fixed tube current at 70mAs with tin filtration in the same session. Forty of the 84 patients (48%) had no emphysema, 44 (52%) had emphysema. One radiologist performed fully automated software-based pulmonary emphysema quantification and lung volumetry of standard and ultralow dose CT with different levels of ADMIRE. Friedman test and Wilcoxon rank sum test were used for multiple comparison of emphysema and lung volume. Lung volumes were compared using the concordance correlation coefficient. The median low-attenuation areas (LAA) using filtered back projection (FBP) in standard dose was 4.4% and decreased to 2.6%, 2.1% and 1.8% using ADMIRE 3, 4, and 5, respectively. The median values of LAA in ultralow dose CT were 5.7%, 4.1% and 2.4% for ADMIRE 3, 4, and 5, respectively. There was no statistically significant difference between LAA in standard dose CT using FBP and ultralow dose using ADMIRE 4 (p=0.358) as well as in standard dose CT using ADMIRE 3 and ultralow dose using ADMIRE 5 (p=0.966). In comparison with standard dose FBP the concordance correlation coefficients of lung volumetry were 1.000, 0.999, and 0.999 for ADMIRE 3, 4, and 5 in standard dose, and 0.972 for ADMIRE 3, 4 and 5 in ultralow dose CT. Ultralow dose CT at chest X-ray equivalent dose levels allows for lung volumetry as well as detection and quantification of emphysema. However, longitudinal emphysema analyses should be performed with the same scan protocol and

  13. Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium

    International Nuclear Information System (INIS)

    Carrasco, P.; Jornet, N.; Duch, M.A.; Weber, L.; Ginjaume, M.; Eudaldo, T.; Jurado, D.; Ruiz, A.; Ribas, M.

    2004-01-01

    An extensive set of benchmark measurement of PDDs and beam profiles was performed in a heterogeneous layer phantom, including a lung equivalent heterogeneity, by means of several detectors and compared against the predicted dose values by different calculation algorithms in two treatment planning systems. PDDs were measured with TLDs, plane parallel and cylindrical ionization chambers and beam profiles with films. Additionally, Monte Carlo simulations by meansof the PENELOPE code were performed. Four different field sizes (10x10, 5x5, 2x2, and1x1 cm 2 ) and two lung equivalent materials (CIRS, ρ e w =0.195 and St. Bartholomew Hospital, London, ρ e w =0.244-0.322) were studied. The performance of four correction-based algorithms and one based on convolution-superposition was analyzed. The correction-based algorithms were the Batho, the Modified Batho, and the Equivalent TAR implemented in the Cadplan (Varian) treatment planning system and the TMS Pencil Beam from the Helax-TMS (Nucletron) treatment planning system. The convolution-superposition algorithm was the Collapsed Cone implemented in the Helax-TMS. The only studied calculation methods that correlated successfully with the measured values with a 2% average inside all media were the Collapsed Cone and the Monte Carlo simulation. The biggest difference between the predicted and the delivered dose in the beam axis was found for the EqTAR algorithm inside the CIRS lung equivalent material in a 2x2 cm 2 18 MV x-ray beam. In these conditions, average and maximum difference against the TLD measurements were 32% and 39%, respectively. In the water equivalent part of the phantom every algorithm correctly predicted the dose (within 2%) everywhere except very close to the interfaces where differences up to 24% were found for 2x2 cm 2 18 MV photon beams. Consistent values were found between the reference detector (ionization chamber in water and TLD in lung) and Monte Carlo simulations, yielding minimal differences (0

  14. Long-term predictions of ambient dose equivalent rates after the Fukushima Daiichi nuclear power plant accident

    International Nuclear Information System (INIS)

    Kinase, Sakae; Saito, Kimiaki; Takahashi, Tomoyuki

    2017-01-01

    To analyze radiation protection strategies and rehabilitation programs in Fukushima, prediction models have been developed for ambient dose equivalent rate distributions within the 80 km-radius around the Fukushima Daiichi nuclear power plant. The prediction models characterized by ecological half-lives of radioactive caesium for land-use, enable Fukushima residents to obtain distribution maps of ambient dose equivalent rates after the Fukushima Daiichi nuclear power plant accident. Model parameters such as the ecological half-lives for the short-term component and the fractional distribution of short-term component were evaluated using ambient dose equivalent rates through car/vehicle-borne surveys. It was found that the ecological half-lives among land-use differ only slightly, whereas the fractional distributions of the short-term component are clearly dependent on land-use. In addition, uncertainties concerning predictions of ambient dose equivalent rates arising from variability in model parameters were assessed using Monte Carlo simulations. Long-term changes of ambient dose equivalent rates were predicted for different land-use areas. Distribution maps of ambient dose equivalent rates for the next 30 years after the accident, created by the prediction models are expected to be useful for follow-up of the radiological situation since they provide information on the space variation of the ambient dose equivalent rates in inhabited areas. (author)

  15. Determination of the equivalent of environmental dose, H*(d), in a radiotherapy installation; Determinacao do equivalente de dose ambiental, H*(d), em uma instalacao de radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Lima, M.A.F.; Borges, J.C. [Universidade Federal de Rio de Janeiro, PEN/COPPE/UFRJ Caixa Postal 68509 21945-970, Rio de Janeiro (Brazil); Mota, H.C. [Instituto de Radio Protecao e Dosimetria, IRD/CNEN Caixa Postal 37750 22780-160, Rio de Janeiro (Brazil)

    1998-12-31

    In order to put into practice radiological protection has been required conversion factors for environmental dose equivalent determination to air kerma value for different kinds of photon and electron beams, such dose values have been determined in a spheric phantom of 30 cm diameter in a alignment field and expanded in a depth of this sphere. Details will be given for determining of equivalent dose distribution calculation using Monte Carlo computational method (ESG4) following the recommendations of ICRU. (Author)

  16. Dynamics of effective dose equivalent in the RSFSR from 90Sr and 137Cs dietary intake

    International Nuclear Information System (INIS)

    Prokof'ev, O.N.; Antonova, V.A.; Golubeva, T.N.

    1987-01-01

    This paper generalizes the long-term observations (1979-1984 Years) of the contents of stratospheric fallout 90 Sr and 137 Cs in main food products and soils of different areas of the USSR. Also, the information is given on 90 Sr content in the human body from the analyses of bone tissue samples and extracted teeth. On the basis of 90 Sr determined in various skeletal tissues and of 137 Cs dietary intake was obtained the dynamics of effective dose equivalent for population of the RSFSR. (author)

  17. Bioequivalence of a fixed-dose repaglinide/metformin combination tablet and equivalent doses of repaglinide and metformin tablets
.

    Science.gov (United States)

    Cho, Hea-Young; Ngo, Lien; Kim, Sang-Ki; Choi, Yoonho; Lee, Yong-Bok

    2018-04-12

    This study was conducted to determine whether a fixed-dose combination (FDC) tablet of repaglinide/metformin (2/500 mg) is equivalent to coadministration of equivalent doses of individual (EDI) tablets of repaglinide (2 mg) and metformin (500 mg) in healthy Korean male subjects. This study was conducted as an open-label, randomized, single-dose, two-period, two-sequence crossover design in 50 healthy Korean male subjects who received an FDC tablet or EDI tablets. Plasma concentrations of repaglinide and metformin were determined for up to 24 hours using a validated UPLC-MS/MS method. Bioequivalence was assessed according to current guidelines issued by the U.S. Food and Drug Administration (FDA) and Korean legislation. Tolerability was also evaluated throughout the study via subject interview, vital signs, and blood sampling. Point estimates (90% CIs) for AUC0-t, AUC0-∞, and Cmax based on EDI tablets were 110.07 (102.25 - 118.49), 109.90 (101.70 - 118.39), and 112.60 (101.49 - 124.85), respectively, for repaglinide. They were 95.18 (89.62 - 101.05), 95.00 (89.74 - 100.65), and 98.44 (92.72 - 104.50), respectively, for metformin. These results satisfied the bioequivalence criteria of 80.00 - 125.00% proposed by the FDA and Korean legislation. Results of pharmacokinetic analysis suggested that repaglinide and metformin in FDC tablets were bioequivalent to EDI tablets of repaglinide (2 mg) and metformin (500 mg) in healthy Korean male subjects. Both formulations appeared to be well tolerated.
.

  18. Efficiency improvement in proton dose calculations with an equivalent restricted stopping power formalism

    Science.gov (United States)

    Maneval, Daniel; Bouchard, Hugo; Ozell, Benoît; Després, Philippe

    2018-01-01

    The equivalent restricted stopping power formalism is introduced for proton mean energy loss calculations under the continuous slowing down approximation. The objective is the acceleration of Monte Carlo dose calculations by allowing larger steps while preserving accuracy. The fractional energy loss per step length ɛ was obtained with a secant method and a Gauss-Kronrod quadrature estimation of the integral equation relating the mean energy loss to the step length. The midpoint rule of the Newton-Cotes formulae was then used to solve this equation, allowing the creation of a lookup table linking ɛ to the equivalent restricted stopping power L eq, used here as a key physical quantity. The mean energy loss for any step length was simply defined as the product of the step length with L eq. Proton inelastic collisions with electrons were added to GPUMCD, a GPU-based Monte Carlo dose calculation code. The proton continuous slowing-down was modelled with the L eq formalism. GPUMCD was compared to Geant4 in a validation study where ionization processes alone were activated and a voxelized geometry was used. The energy straggling was first switched off to validate the L eq formalism alone. Dose differences between Geant4 and GPUMCD were smaller than 0.31% for the L eq formalism. The mean error and the standard deviation were below 0.035% and 0.038% respectively. 99.4 to 100% of GPUMCD dose points were consistent with a 0.3% dose tolerance. GPUMCD 80% falloff positions (R80 ) matched Geant’s R80 within 1 μm. With the energy straggling, dose differences were below 2.7% in the Bragg peak falloff and smaller than 0.83% elsewhere. The R80 positions matched within 100 μm. The overall computation times to transport one million protons with GPUMCD were 31-173 ms. Under similar conditions, Geant4 computation times were 1.4-20 h. The L eq formalism led to an intrinsic efficiency gain factor ranging between 30-630, increasing with the prescribed accuracy of simulations. The

  19. Job embeddedness scoring: measurement equivalence between rural and urban nurses.

    Science.gov (United States)

    Reitz, O Ed; Kim, MyoungJin

    2013-01-01

    This study examined the measurement equivalency (ME) of the job embeddedness (JE) instrument for rural and urban registered nurses (RNs) using a secondary analysis of a cross-sectional mailed survey. JE represents the sum of reasons an employee remains at the present job. RNs from both rural and urban areas returned a 40-item JE instrument designed to assess their level of embeddedness. Analysis was performed using a multi-group confirmatory factor analysis for JE ratings of rural and urban RNs. The findings indicated that the original 40-item JE instrument needed to be respecified to achieve adequate fit for the sample of rural and urban RNs. This 32-item respecified instrument demonstrated that rural and urban RNs use the same metric when giving ratings for JE items. The findings of ME across rural and urban RNs facilitate comparisons between the two groups. The implications of these findings are that differences in ratings between rural and urban RNs may be attributed to real differences and not merely measurement artifact. Examination of these differences may lead to real strategies to retain nurses, thus mitigating the impact of the global nursing shortage.

  20. Evaluation of the directional dose equivalent H,(0.07) for ring dosemeters

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Tovar M, V.M.

    2006-01-01

    The personnel dosimetry laboratory (LDP) of the Metrology department received an user's of radiation beta application that incidentally had irradiated 14 couples of ring dosemeters for extremities of the type TLD-100 given by the LDP. This sample of 14 couples of rings tentatively it was irradiated in the months of July-August of the year 2004, and he requested in an expedite way the evaluation of the received dose equivalent. The LSCD builds two calibration curves in terms of the directional dose equivalent H'(0.07) using two sources patterns of 90 Sr- 90 Y for beta radiation: one of 74 MBq and another of 1850 MBq with traceability to the PTB. The first curve in the interval of 0 to 5 mSv, the second in the range of 5 to 50 mSv, taking into account effects by positioned of the rings in the phantom. Both calibration curves were validated by adjustment lack, symmetry of residuals and normality of the same ones. It is evaluated and analyzing the H'(0.007) for these 14 couples of rings using the Tukey test of media of a single road. It was found that the H , its could be classified in 4 groups, and that the probability that its has irradiated in a random way it was smaller to the level at α = 0.05. (Author)

  1. The monetary value of the collective dose equivalent unit (person-rem)

    International Nuclear Information System (INIS)

    Rodgers, Reginald C.

    1978-01-01

    In the design and operation of nuclear power reactor facilities, it is recommended that radiation exposures to the workers and the general public be kept as 'low as reasonably achievable' (ALARA). In the process of implementing this principle cost-benefit evaluations are part of the decision making process. For this reason a monetary value has to be assigned to the collective dose equivalent unit (person-rem). The various factors such as medical health care, societal penalty and manpower replacement/saving are essential ingredients to determine a monetary value for the person-rem. These factors and their dependence on the level of risk (or exposure level) are evaluated. Monetary values of well under $100 are determined for the public dose equivalent unit. The occupational worker person-rem value is determined to be in the range of $500 to about $5000 depending on the exposure level and the type of worker and his affiliation, i.e., temporary or permanent. A discussion of the variability and the range of the monetary values will be presented. (author)

  2. Understanding differences in dose-equivalents reported by passive and electronic personal dosemeters

    International Nuclear Information System (INIS)

    Perks, Christopher A.; Burgess, Peter; Smith, David; Salasky, Mark; Yahnke, Cliff

    2008-01-01

    Full text: In a number of challenging environments, clients occasionally double badge with electronic personal dosemeters (EPDs) to ensure day-to-day management of their employees personal dose-equivalent while using passive (in our case Luxel or InLight) dosemeters for monthly monitoring for approved results for dose record keeping. In some cases there have been significant differences in the cumulative doses recorded by the EPDs and the passive dosemeters. In these circumstances the passive dosemeters usually report a higher dose than the EPD by up to a factor of two, though more commonly 1.3. In this paper we describe the differences seen between EPD and passive dosemeters (in a number of countries). We then examine the possible causes for such discrepancies by comparison with published response function data available for the EPDs and Landauer dosemeters. We have undertaken a number of experiments comparing directly a number of EPDs and passive dosemeter response to a variety of energy and complex angular geometries where the two types of dosimeter have been exposed at the same time. Recommendations will be made on the appropriate use of double badging in difficult environments and interpretation of the results. (author)

  3. Procedures for operational monitoring of the environmental equivalent doses in cobalt therapy

    International Nuclear Information System (INIS)

    Perez Velasquez, Reytel; Gonzalez Lopez, Nadia; Perez Tamayo, Luis

    2009-01-01

    It took as its object of study environmental equivalent dose rates of field radiation they face radiophysicists technicians and medical physicists in the irradiation site of the radiation department of Lenin Hospital in Holguin, and the public that travels or remains in premises and areas surrounding the campus. It A review of national and international publications as well as technical documents to study the state of the art of the methodological existing monitoring of those dose rates and the valuation of impact in the context of an environmental management system. Since no detailed instructions and to perform the above-mentioned monitoring was proposed structure should contain a procedure to regulate the steps for this monitoring in the radiotherapy department of the Lenin Hospital Holguin, for which we studied the guidelines of NC ISO 14000 , and was conducted wide experiment whose led to: illustrate the level of doses required workers exposed occupationally exposed to radiation and the public compare these levels with natural radiation sources, assess the effectiveness of shielding the site of irradiation and the points of greatest risk within and outside the enclosure irradiation.Also assessed the impact it can have on the health of people exposed to such doses. Finally, we proposed a procedure for conducting subsequent monitoring and made recommendations to reduce levels radiation determined the lowest level reasonably achievable. (author)

  4. Radiation dose rate measuring device

    International Nuclear Information System (INIS)

    Sorber, R.

    1987-01-01

    A portable device is described for in-field usage for measuring the dose rate of an ambient beta radiation field, comprising: a housing, substantially impervious to beta radiation, defining an ionization chamber and having an opening into the ionization chamber; beta radiation pervious electrically-conductive window means covering the opening and entrapping, within the ionization chamber, a quantity of gaseous molecules adapted to ionize upon impact with beta radiation particles; electrode means disposed within the ionization chamber and having a generally shallow concave surface terminating in a generally annular rim disposed at a substantially close spacing to the window means. It is configured to substantially conform to the window means to define a known beta radiation sensitive volume generally between the window means and the concave surface of the electrode means. The concave surface is effective to substantially fully expose the beta radiation sensitive volume to the radiation field over substantially the full ambient area faced by the window means

  5. Radial dose, LET, and W-bar for 16O ions in N2 and tissue-equivalent gases

    International Nuclear Information System (INIS)

    Varma, M.N.; Baum, J.W.; Kuehner, A.V.

    1977-01-01

    Average energy to produce an ion pair (anti W), distance restricted, and total linear energy transfer and dose as a function of radial distance D(r) from the ion's path were measured for 41.1-MeV 16 O ions in nitrogen and Rossi-type tissue-equivalent gas. Results for anti W were 38.9 +- 0.54 eV/ion pair for nitrogen and 33.4 +- 0.47 eV/ion pair for tissue-equivalent gas. Results for total linear energy transfer (LET/sub infinity/) were 6507 MeV . cm 2 g -1 for tissue-equivalent gas and 6210 MeV . cm 2 g -1 for nitrogen. Results for D(r) were used to calculate similar values to be expected in tissue-like material having a density of 1 g/cm 3 . The range of radial distances covered was from 0.2 to 300 nm in tissue. Results are compared with calculations based on Paretzke's continuous slowing down model. Measured D(r) values in nitrogen were randomly distributed about the calculated values between radial distances of 0.56 and 286 nm. The mean deviation between the experimental and the calculated value was 1.3% (the experimental value being higher). For tissue-equivalent gas, previously measured D(r) values were also randomly distributed about the calculated values, with a mean deviation of 4% (the experimental value being lower) between radial distances of 1.5 and 140 nm

  6. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    Enrique

    between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from the source. The study included the interventional radiolo- gists, radiographers and nurses ...

  7. Absorbed dose to water reference dosimetry using various water-equivalent solid phantoms in high-energy photon beams

    International Nuclear Information System (INIS)

    Araki, Fujio; Hanyu, Yuji; Okumura, Masahiko

    2007-01-01

    Most recent megavoltage dosimetry protocols (e.g., the Japan Society of Medical Physics (JSMP) (JSMP-01), the American Association of Physicists in Medicine (AAPM) (TG-51), and the International Atomic Energy Agency (IAEA) (TRS-398)) have limited to the use of liquid water as a phantom material for reference dose measurements. This is because water is well-defined and reproducibly available compared to water-equivalent solid phantoms. This study presents methods to determine absorbed dose to water using ionization chambers calibrated in terms of absorbed dose to water but irradiated in solid phantoms. Achieving solid phantom measurements on an absolute basis has distinct advantages in verification measurements and quality assurance. We provide a depth scaling factor that transfers a depth in the solid phantom to a water equivalent depth and an ionization conversion factor (ionization ratio) that converts a chamber reading in the solid phantom to that in water. The absorbed dose to water under reference conditions can be obtained from the solid phantom measurements by using the two factors. We calculated the depth scaling factor for four solid phantoms (Solid Water RMI457, Tough Water WE211, RW3, and MixDP) for photon energies between 4 and 18 MV. The calculated average scaling factor for each phantom agreed within 1.5% compared with the relative electron density. For various Farmer-type cylindrical chambers, we also calculated and measured the ionization conversion factor for the four solid phantoms. The solid phantom measurements were performed at many hospitals. For RMI457 and WE211, the differences between measured and calculated factors varied between -0.5% and 0.7% with the average ionization conversion factor 0.3% lower than the calculation, whereas RW3 agreed within 0.5% after one phantom examination. Similarly, the differences for MixDP ranged from -0.2% to -1.5% with the average 1.0% lower than the calculation. The composition of commercial plastic

  8. Potential factors that impact the radon level and the prediction of ambient dose equivalent rates of indoor microenvironments.

    Science.gov (United States)

    Ali, Mohamed Yasreen Mohamed; Hanafiah, Marlia M; Khan, Md Firoz

    2018-01-11

    This study aimed to measure the equilibrium equivalent radon (EEC Rn ) concentration in an old building (Building-1) and a new building (Building-2) with mechanical ventilation and a natural ventilation system, respectively. Both buildings were located at the campus of University Kebangsaan Malaysia. The concentration of indoor radon was measured at 25 sampling stations using a radon detector model DOSEman PRO. The sampling was conducted for 8 h to represent daily working hours. A correlation of the radon concentration was made with the annual inhalation dose of the occupants at the indoor stations. The equilibrium factor and the annual effective dose on the lung cancer risks of each occupant were calculated at each sampling station. The average equilibrium equivalent radon measured in Building-1 and Building-2 was 2.33 ± 0.99 and 3.17 ± 1.74 Bqm -3 , respectively. The equilibrium factor for Building 1 ranged from 0.1053 to 0.2273, and it ranged from 0.1031 to 0.16 for Building 2. The average annual inhalation doses recorded at Building-1 and Building-2 were 0.014 ± 0.005 mSv y -1 and 0.020 ± 0.013 mSv y -1 , respectively. The annual effective dose for Building-1 was 0.034 ± 0.012 mSv y -1 , and it was 0.048 ± 0.031 mSv y -1 for Building-2. The values of equilibrium equivalent radon concentration for both buildings were below the standard recommended by the International Commission on Radiological Protection (ICRP). However, people may have different radon tolerance levels. Therefore, the inhalation of the radon concentration can pose a deleterious health effect for people in an indoor environment. Copyright © 2018. Published by Elsevier B.V.

  9. Measurement of neutron dose in the compensator IMRT treatment.

    Science.gov (United States)

    Rezaian, Abbas; Nedaie, Hassan Ali; Banaee, Nooshin

    2017-10-01

    A radiation treatment delivery technique, intensity modulated radiation therapy (IMRT), has found widespread use in the treatment of cancers. One of IMRT implementing methods is IMRT compensator based, which the modulation are done by high Z materials. When photons with energies higher than 8MV interact with high Z material in path, Photoneutrons are produced. In this study, the effect of compensator on photoneutron production was investigated. The Monte Carlo code MCNPX was used to calculate the neutron dose equivalent as a function of the depth in phantom with and without compensator. Measurements were made using CR-39 track-etched detectors. CR-39 detectors, were cut in dimensions of 2.5×2.5 cm 2 by laser, placed in different depths of slab phantom and then irradiated by 18MV photons. Same procedure was performed with the compensator present and absent. The measured data were compared with MCNP calculations. In both experimental and simulation results, neutron dose equivalent when compensator used, was less than non-compensator field. The calculated neutron dose equivalent was maximum at surface and decreased exponentially by increasing depth, but in experimental data, the neutron dose equivalent reached a maximum at approximately 3cm depth in the phantom and beyond which decreased with depth.CR-39 calibration was carried out in air, by considering that neutron energy spectrum changes toward thermal neutrons by depth in phantom increasing, it is suggested that for measuring equivalent neutron dose at phantom depth, should have proper neutron calibration in terms of energy spectrum. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. A new concept in radiation dose calculation by using of 1 cm dose equivalent rate constant with shielding effect and accompanying software

    International Nuclear Information System (INIS)

    Nakamura, Ayako; Yamano, Toyotsugu

    2000-01-01

    A new concept called 1 cm dose equivalent rate constant with shielding effect is introduced for estimation of radiation dose. This new concept represents an expansion of the former standard 1 cm dose equivalent rate constant (defined as μSv·m 2 ·MBq -1 ·h -1 ) adjusted attenuation for any given thickness of shielding material (iron, lead and concrete). The 1 cm dose equivalent rate constant with shielding effect for various shielding conditions can be rapidly computed with a free-software application, KINGS-B621, which may be easily downloaded from the internet. The computed rate constants can be put out as text files which are compatible with commercially available spread-sheet software, so it is easy for users to apply the data to creation of documents concerning radiation dose. (author)

  11. Atmospheric Cosmic-Ray Variation and Ambient Dose Equivalent Assessments Considering Ground Level Enhancement Thanks to Coupled Anisotropic Solar Cosmic Ray and Extensive Air Shower Modeling.

    Science.gov (United States)

    Hubert, Guillaume; Aubry, Sébastien

    2017-11-01

    This work investigates the impact of Forbush decrease (FD) and ground-level enhancement (GLE) in the atmosphere, based on solar and galactic cosmic-ray models and the extensive air shower simulations. This approach gives the possibility to investigate both the dynamic behavior of neutron monitors (NM) (using response function) and the flight dose. The ambient dose equivalent during quiet solar activity and solar events (i.e., FDs and GLEs) were investigated for realistic flight plans issued from the Eurocontrol Demand Data Repository. The calculated ambient dose equivalents were compared with flight measurements in quiet solar conditions; comparisons are relevant and demonstrate the ability to estimate the dose level. The GLE model was validated for the GLEs 5 and 69 using the cosmic-ray variation recorded by NMs. The GLE model was applied to flight dose calculations. All of these results show that dose values vary drastically with the route path (latitude, longitude and altitude) and with the delay between the flight departure and the solar event occurrence. Doses induced by extreme GLE events were investigated specifically for London to New York flights, and resulting additional doses are a few hundred or 1,000 μSv, impacting significantly the annual effective dose. This highlights the importance of monitoring extreme solar events and using realistic semi-empirical and particle transport methods for reliable calculation of dose levels.

  12. Evaluation of dose equivalent to the people accompanying patients in diagnostic radiology using MCNP4C Monte Carlo code

    International Nuclear Information System (INIS)

    Mehdizadeh, S.; Faghihi, R.; Sina, S.; Zehtabian, M.

    2007-01-01

    Complete text of publication follows. Objective: X rays used in diagnostic radiology contribute a major share to population doses from man-made sources of radiation. In some branches of radiology, it is necessary that another person stay in the imaging room and immobilize the patient to carry out radiological operation. ICRP 70 recommends that this should be done by parents or accompanying nursing or ancillary personnel and not in any case by radiation workers. Methods: Dose measurements were made previously using standard methods employing LiF TLD-100 dosimeters. A TLD card was installed on the main trunk of the body of the accompanying people where the maximum dose was probable. In this research the general purpose Monte Carlo N-particle radiation transport computer code (MCNP4C) is used to calculate the equivalent dose to the people accompanying patients exposed to radiation scattered from the patient (Without protective clothing). To do the simulations, all components of the geometry are placed within an air-filled box. Two homogeneous water phantoms are used to simulate the patient and the accompanying person. The accompanying person leans against the table at one side of the patient. Finally in case of source specification, only the focus of the X-ray tube is modelled, i.e. as a standard MCNP point source emitting a cone of photons. Photon stopping material is used as a collimator model to reduce the circular cross section of the cone to a rectangle. The X-ray spectra to be used in the MCNP simulations are generated with spectrum generator software, taking the X-ray voltage and all filtration applied in the clinic as input parameters. These calculations are done for different patient sizes and for different radiological operations. Results: In case of TL dosimetry, for a group of 100 examinations, the dose equivalents ranged from 0.01 μsv to 0.13 msv with the average of 0.05 msv. The results are seen to be in close agreement with Monte Carlo simulations

  13. Conversion coefficients from air kerma to personal dose equivalent in mammography

    Energy Technology Data Exchange (ETDEWEB)

    Kuenzel, R., E-mail: roselikunzel@gmail.co [Area de Ciencias Naturais e Tecnologicas, Centro Universitario Franciscano, Rua dos Andradas 1614, 97010-032 Santa Maria, RS (Brazil); Levenhagen, R.S. [Universidade Nove de Julho, Av. Dr. Adolfo Pinto, 109, Barra Funda, 01156-050 Sao Paulo (Brazil); Herdade, S.B. [Secao Tecnica de Desenvolvimento Tecnologico em Saude, Instituto de Eletrotecnica e Energia, Universidade de Sao Paulo, Avenida Professor Luciano Gualberto, 1289, Cidade Universitaria, CEP 05508-010 Sao Paulo (Brazil)

    2010-05-15

    In this work, the scattered X-ray beams produced by a mammography unit with a Mo/Mo, Mo/Rh and W/Rh anode/filter combinations were applied in the evaluation of the H{sub p}(10,0{sup 0}) and mean conversion coefficients from air kerma to the personal dose equivalent (C-bar{sub H{sub p(10,0{sup 0})}}). The higher values of H{sub p}(10,0{sup 0}) are related to the Mo/Rh combination whereas the lower ones are for the W/Rh target/filter. C-bar{sub H{sub p(10,0{sup 0})}} values are in the range 0.19-0.54 Sv/Gy, where the higher values comprise the W/Rh combination.

  14. Dose-equivalent response CR-39 track detector for personnel neutron dosimetry

    International Nuclear Information System (INIS)

    Oda, K.; Ito, M.; Yoneda, H.; Miyake, H.; Yamamoto, J.; Tsuruta, T.

    1991-01-01

    A dose-equivalent response detector based on CR-39 has been designed to be applied for personnel neutron dosimetry. The intrinsic detection efficiency of bare CR-39 was first evaluated from irradiation experiments with monoenergetic neutrons and theoretical calculations. In the second step, the radiator effect was investigated for the purpose of sensitization to fast neutrons. A two-layer radiator consisting of deuterized dotriacontane (C 32 D 66 ) and polyethylene (CH 2 ) was designed. Finally, we made the CR-39 detector sensitive to thermal neutrons by doping with orthocarbone (B 10 H 12 C 2 ), and also estimated the contribution of albedo neutrons. It was found that the new detector - boron-doped CR-39 with the two-layer radiator - would have a flat response with an error of about 70% in a wide energy region, ranging from thermal to 15 MeV. (orig.)

  15. Effective Dose Equivalent To The Cypriot Population Due To Natural Radiation

    International Nuclear Information System (INIS)

    Christofides, S.

    1994-01-01

    A study was initiated by the Biomedical Research Foundation, two years ago, to estimate the various natural radiation components that contribute to the Effective Dose Equivalent (EDE) to the Cypriot population. The present study has shown that the contribution due to cosmic radiation is estimated to be less than 270 microSiverts per annum, while that due to airborne Rn-222 concentration in Cypriot houses is estimated to be less then 330 microSieverts per annum. The contribution due to terrestrial gamma radiations, which is currently under investigation, is so far estimated to be around 108 microSieverts per annum. Therefore the EDE to the Cypriot population due to natural radiation is likely to be around 700 microSieverts per annum, not taking into account the internal exposure due to other naturally occuring radionuclides. (author)

  16. Determination of the dose equivalent Hp(0.07) in hands of occupationally exposed personnel in the practice of proton emission tomography (PET/CT)

    International Nuclear Information System (INIS)

    Lea, D.; Ruiz, N.; Esteves, L.

    2006-01-01

    In Venezuela recently it was implanted the Positron Emission Tomography technique (PET) with the perspective of implanting it at national level. Even when in our country practices it of nuclear medicine it exists from early of 70, there is not experience in the determination of the occupational doses by exposure to the external radiation in hands. By this reason, a concern exists in the workers of the centers of nuclear medicine where it is practiced the Positron Emission Tomography technique. In absence of the TLD dosimetry to measure dose in hands in our country, measurements of the dose equivalent of the workers of the PET national reference center were made, using a detector of hands type diode. It was determined the dose in hands in terms of dose equivalent Hp(0.07) in two work positions, that is: the corresponding to the transfer of the receiving vial of ( 18 F) FDG to the shield, quality control and uni doses division. The second work position corresponds the person in charge of administering, via intravenous, the ( 18 F) FDG. In this work it realizes the dose equivalent in hands Hp(0.07) measures in each one of the work positions before described by daily production. The informed doses correspond to a total average produced activity of 20.4 GBq (550 mCi). The results of the measurements in terms of dose equivalent in hands Hp(0.07) correspond to 2.1 ± 20% mSv in the work position of division and 0.4 ± 10% mSv in the position of injection of the radioactive material. At short term this foreseen until 4 productions per week, what means an annual dose equivalent Hp(0.07) in hands of 400 mSv approximately, without taking into account abnormal situations as its are spills of the ( 18 F) FDG in the work place. This work is the starting point so that the regulatory authority settles down, in Venezuela, dose restrictions in the PET practices and implant, in the centers of nuclear medicine, an optimization politics of this practice in conformity with the ALARA

  17. Effective Equivalent Doses of External Irradiation of Population by Man-made Radionuclides from the Soil in the Sarajevo Region Over the Period of 1986-1989

    International Nuclear Information System (INIS)

    Saracevic, L.; Samek, D.; Hasanbasic, D.; Gradascevic, N.

    1998-01-01

    Assessment of exposition of human body to radioactive materials is seen as radiation-hygienic measure of utmost importance, since the doses absorbed due to radionuclides present in soil, air, food and water are significant integral parts of the total dose that the human being receives in all kinds and conditions of exposition. External irradiation by radionuclides deposed in soil is a major contributor to the whole dose of irradiation of population. Assuming that fission radionuclides Cs-134 and Cs-137 had a specially significant contribution to the total dose of irradiation of the population over the investigation period (1986-1989), we established their levels of activity in the soil in different localities of the Sarajevo region, and then calculated the effective equivalent dose for the population for each year of investigation. The mean values for the yearly effective equivalent doses of external irradiation of the population by fission radionuclides Cs-134 and Cs-137 from the soil in the Sarajevo region were 0.77 mSv/year in 1989. Contribution by Cs-134 to the total effective equivalent dose was 63.64 % in 1986 year, to be reeducated in 1987 to 45.67 %, in 1988 to 35.89 % and in the year 1989 to 33.33 %. The effective equivalent dose was different to a great extent by the investigated localities (town sections) during the started period. It can be inferred from the above that the average population of the Sarajevo region did not receive a larger dose of radiation than the one established by the International Commission for Radiological Protection as the limit for subsequent exposition to radiation. (author)

  18. Measurement model equivalence in web- and paper-based surveys ...

    African Journals Online (AJOL)

    The aim of this research is to investigate whether web-based and paper-based organisational climate surveys can be regarded as equivalent techniques of data collection. Due to the complex geographical placement of various units of the participating organisation and limited internet access, both paper-based and

  19. Optimal use of β-blockers in high-risk hypertension: A guide to dosing equivalence

    Directory of Open Access Journals (Sweden)

    Janet B McGill

    2010-05-01

    Full Text Available Janet B McGillDepartment of Medicine, Washington University School of Medicine, St. Louis, Missouri, USAAbstract: Hypertension is the number one diagnosis made by primary care physicians, placing them in a unique position to prescribe the antihypertensive agent best suited to the individual patient. In individuals with diabetes mellitus, blood pressure (BP levels > 130/80 mmHg confer an even higher risk for cardiovascular and renal disease, and these patients will benefit from aggressive antihypertensive treatment using a combination of agents. β‑blockers are playing an increasingly important role in the management of hypertension in high-risk patients. β‑blockers are a heterogeneous class of agents, and this review presents the differences between β‑blockers and provides evidence-based protocols to assist in understanding dose equivalence in the selection of an optimal regimen in patients with complex needs. The clinical benefits provided by β‑blockers are only effective if patients adhere to medication treatment long term. β‑blockers with proven efficacy, once-daily dosing, and lower side effect profiles may become instrumental in the treatment of hypertensive diabetic and nondiabetic patients.Keywords: antihypertensive, blood pressure, atenolol, carvedilol, labetalol, metoprolol, nebivolol

  20. Derivation of a reference dose and drinking water equivalent level for 1,2,3-trichloropropane.

    Science.gov (United States)

    Tardiff, Robert G; Carson, M Leigh

    2010-06-01

    In some US potable water supplies, 1,2,3-trichloropropane (TCP) has been present at ranges of non-detect to less than 100 ppb, resulting from past uses. In subchronic oral studies, TCP produced toxicity in kidneys, liver, and other tissues. TCP administered by corn oil gavage in chronic studies produced tumors at multiple sites in rats and mice; however, interpretation of these studies was impeded by substantial premature mortality. Drinking water equivalent levels (DWELs) were estimated for a lifetime of consumption by applying biologically-based safety/risk assessment approaches, including Monte Carlo techniques, and with consideration of kinetics and modes of action, to possibly replace default assumptions. Internationally recognized Frameworks for human relevance of animal data were employed to interpret the findings. Calculated were a reference dose (=39 microg/kg d) for non-cancer and Cancer Values (CV) (=10-14 microg/kg d) based on non-linear dose-response relationships for mutagenicity as a precursor of cancer. Lifetime Average Daily Intakes (LADI) are 3130 and 790-1120 microg/person-d for non-cancer and cancer, respectively. DWELs, estimated by applying a relative source contribution (RSC) of 50% to the LADIs, are 780 and 200-280 microg/L for non-cancer and cancer, respectively. These DWELs may inform establishment of formal/informal guidelines and standards to protect public health. Copyright 2010 Elsevier Ltd. All rights reserved.

  1. Comparison of diagnostic protocols and the equivalent effective dose in renal cancer and herniated lumbar disc

    International Nuclear Information System (INIS)

    Ruiz Perez de Villar, M.J.; Vano Carruana, E.; Lanzos Gonbzalez, E.; Perez Torrubia, A.

    1994-01-01

    Renal cancer (RC) and herniated lumbar disc (HLD) were the two pathologies selected for the study of the diagnostic protocols applied in different centers to determine how their variability is reflected in the effective equivalent dose (EED) and establish the optimal radiological protocol for diagnostic purposes, while using the lowest possible dose. On the basis of 222 case histories, it was observed that the EED resulting from the diagnosis of HLD can vary as much as a factor of 3(6.2-18.9 mSv). Likewise, the EED related to the diagnosis of RC can be modified by a factor of 1.5(32.6-48.3 mSv), depending on the diagnostic protocol employed. It can be considered that the optimal protocol to reach a diagnosis of HLD includes chest x-ray, lumbar spine x-ray and lumbar CT scan, while that required for the diagnosis of RC involves chest x-ray, IVU, abdominal CT scan and digital subtraction angiography. The optimization of the study protocols-especially the reduction of the number of exposures, modernization and quality control of the equipment, among other aspects, can reduce the EED by a factor of 2. (Author)

  2. Effective and equivalent doses for CT head examinations calculated using the voxelized phantoms MASH and FASH

    Science.gov (United States)

    Ferreira, C. C.; Folly, W. S. D.; Vieira, J. W.; Maia, A. F.

    2011-09-01

    The voxelized phantoms MASH and FASH have been used for calculating conversion coefficients (CCs) for a specific CT head examination performed in a specific Toshiba CT scanner. The X-ray spectrum was selected according to the concordance between the calculated C 100,c and measured C 100,c. For 120 kV, the X-raytbc code presented the smaller deviation, equal to -7.11%. Finally, effective doses calculated for the voxelized phantoms MASH and FASH were 6.1 and 4.5, respectively, smaller than the effective dose obtained though the European guidelines on quality criteria for computed tomography.

  3. Entrance and peripheral dose measurements during radiotherapy

    International Nuclear Information System (INIS)

    Sulieman, A.; Kappas, K.; Theodorou, K.

    2008-01-01

    In vivo dosimetry of entrance dose was performed using thermoluminescent dosimeters (TLD) in order to evaluate the clinical application of the build up caps in patient dose measurements and for different treatment techniques. Peripheral dose (thyroid and skin) was measured for patients during breast radiotherapy to evaluate the probability of secondary cancer induction. TLD-100 chips were used with different Copper build up caps (for 6 MV and 15 MV photon beams from two linear accelerators. Entrance doses were measured for patients during radiotherapy course for breast, head and neck, abdomen and pelvis malignancies. The measured entrance dose for the different patients for 6 MV beams is found to be within the ±2.6% compared to the dose derived from theoretical estimation (normalized dose at D max ). The same measurements for 15 MV beams are found to be ±3 %. The perturbation value can reach up to 20% of the D max , which acts as a limitation for entrance dose measurements. An average thyroid skin dose of 3.7% of the prescribed dose was measured per treatment session while the mean skin dose breast treatment session is estimated to be 42% of D max , for both internal and external fields. These results are comparable in those of the in vivo of reported in literature. The risk of fatality due to thyroid cancer per treatment course is 3x10 -3

  4. The European Person Equivalent: Measuring the personal environmental space

    DEFF Research Database (Denmark)

    Hauschild, Michael Zwicky; Wenzel, Henrik

    2001-01-01

    The European person equivalent (PE) is a quantification of the environmental impact caused annually by the activities of an average European. It comprises contributions to all the major environmental impacts from global to local as well as our consumption of resources. Similarly, the targeted...... European person equivalent is a quantification of the average person’s environmental impact in a near future according to the current politically set environmental targets. In addition to expressing the current societal priorities in pollution reduction, the targeted PE expresses the environmental space...... available to all of us according to the current environmental policy. Both concepts were developed in the mid-nineties for use in life cycle impact assessment to help comparisons across different environmental impact categories. Since then they have shown their value as a pedagogic tool in the presentation...

  5. A study of dose equivalent for the nurses in Hirosaki University Hospital

    International Nuclear Information System (INIS)

    Kon, Masanori; Abe, Katsumi

    2001-01-01

    The annual relationships in 1997-1999 between exposure dose of those nurses engaging in full-time radiological works and the number of patients subjected to radiological examinations were investigated in authors' hospital. The annual number of those patients was rather constant. Exposure was measured by film-, carrot- and ring-badges. Eight to nine nurses engaged in radiological examinations like CT, fluoroscopy, urinary tract fluoroscopy and angiography, and other 8 nurses, therapy with sealed 137 Cs and 192 Ir and unsealed 131 I as well. No significant changes in exposure dose were observed in the former group of nurses and in the latter. The dose decreased annually to the level of the former due to skill advancement. (K.H.)

  6. Additional annual collective effective dose equivalent for population living in buildings of stone-like coal cinder materials

    International Nuclear Information System (INIS)

    Li Suyun

    1989-01-01

    A rough estimation of the additional annual collective effective dose equivalent was given for population living in buildings made of stone-like coal cinder bricks. The mean equilibrium-equivalent radon concentration was found to be 84 Bq/m 3 higher, and absorbed dose rate of gamma radiation 48.0 x 10 -8 Gy/h more, than that in control houses. The annual collective effective dose equivalent for population living in buildings of stone-like coal cinder bricks produced during one year was estimated to be 278.87 person-severt (with using a retention factor of 0.8) or 272.63 person-severt (with using a retention factor of 0.65)

  7. Teacher ratings of ODD symptoms: measurement equivalence across Malaysian Malay, Chinese and Indian children.

    Science.gov (United States)

    Gomez, Rapson

    2014-04-01

    The study examined the measurement equivalence for teacher ratings across Malaysian Malay, Chinese and Indian children. Malaysian teachers completed ratings of the ODD symptoms for 574 Malay, 247 Chinese and 98 Indian children. The results supported the equivalences for the configural, metric, and error variances models, and the equivalences for ODD latent variances and mean scores. Together, these findings suggest good support for measurement and structural equivalences of the ODD symptoms across these ethnic groups. The theoretical and clinical implications of the findings for cross-cultural equivalence of the ODD symptoms are discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Estimation of equivalent dose on the ends of hemodynamic physicians during neurological procedures; Avaliacao da dose equivalente nas extremidades de medicos hemodinamicistas durante procedimentos neurologicos

    Energy Technology Data Exchange (ETDEWEB)

    Squair, Peterson L.; Souza, Luiz C. de; Oliveira, Paulo Marcio C. de [Universidade FUMEC, Belo Horizonte, MG (Brazil). Radiologia e Protecao Radiologica; Nogueira, Maria do S. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2005-07-01

    The estimation of doses in the hands of physicists during hemodynamic procedures is important to verify the application of radiation protection related to the optimization and limit of dose, principles required by the Portaria 453/98 of Ministry of Health/ANVISA, Brazil. It was checked the levels of exposure of the hands of doctors during the use of the equipment in hemodynamic neurological procedures through dosimetric rings with thermoluminescent dosemeters detectors of LiF: Mg, Ti (TLD-100), calibrated in personal Dose equivalent HP (0.07). The average equivalent dose in the end obtained was 41.12. {mu}Sv per scan with an expanded uncertainty of 20% for k = 2. This value is relative to the hemodynamic Neurology procedure using radiological protection procedures accessible to minimize the dose.

  9. A Comparison of Equivalent Doses of Lidocaine and Articaine in Maxillary Posterior Tooth Extractions: Case Series

    Directory of Open Access Journals (Sweden)

    Christopher C. Friedl

    2012-06-01

    Full Text Available Objectives: Local anaesthesia is the standard of care during dental extractions. With the advent of newer local anesthetic agents, it is often difficult for the clinician to decide which agent would be most efficacious in a given clinical scenario. This study assessed the efficacy of equal-milligram doses of lidocaine and articaine in achieving surgical anaesthesia of maxillary posterior teeth diagnosed with irreversible pulpitis. Material and Methods: This case-series evaluated a total of 41 patients diagnosed with irreversible pulpitis in a maxillary posterior tooth. Patients randomly received an infiltration of either 3.6 mL (72 mg 2% lidocaine with 1:100,000 epinephrine or 1.8 mL (72 mg 4% articaine with 1:100,000 epinephrine in the buccal fold and palatal soft tissue adjacent to the tooth. After 10 minutes, initial anaesthesia of the tooth was assessed by introducing a sterile 27-gauge needle into the gingival tissue adjacent to the tooth, followed by relief of the gingival cuff. Successful treatment was considered to have occurred when the tooth was extracted with no reported pain. Data was analyzed with the Fisher’s exact test, unpaired t-test and normality test. Results: Twenty-one patients received lidocaine and 20 received articaine. Forty of the 41 patients achieved initial anaesthesia 10 minutes after injection: 21 after lidocaine and 19 after articaine (P = 0.488. Pain-free extraction was accomplished in 33 patients: 19 after lidocaine and 14 after articaine buccal and palatal infiltrations (P = 0.226. Conclusions: There was no significant difference in efficacy between equivalent doses of lidocaine and articaine in the anaesthesia of maxillary posterior teeth with irreversible pulpitis.

  10. SOILD: A computer model for calculating the effective dose equivalent from external exposure to distributed gamma sources in soil

    International Nuclear Information System (INIS)

    Chen, S.Y.; LePoire, D.; Yu, C.; Schafetz, S.; Mehta, P.

    1991-01-01

    The SOLID computer model was developed for calculating the effective dose equivalent from external exposure to distributed gamma sources in soil. It is designed to assess external doses under various exposure scenarios that may be encountered in environmental restoration programs. The models four major functional features address (1) dose versus source depth in soil, (2) shielding of clean cover soil, (3) area of contamination, and (4) nonuniform distribution of sources. The model is also capable of adjusting doses when there are variations in soil densities for both source and cover soils. The model is supported by a data base of approximately 500 radionuclides. 4 refs

  11. Significance and principles of the calculation of the effective dose equivalent for radiological protection of personnel and patients

    International Nuclear Information System (INIS)

    Drexler, G.; Williams, G.

    1985-01-01

    The application of the effective dose equivalent, Hsub(E), concept for radiological protection assessments of occupationally exposed persons is justifiable by the practicability thus achieved with regard to the limiting principles. Nevertheless, it would be proper logic to further use as the basic limiting quantity the real physical dose equivalent of homogeneous whole-body exposure, and for inhomogeneous whole-body irradiation the Hsub(E) value, calculated by means of the concept of the effective dose equivalent. For then the required concepts, models and calculations would not be connected with a basic radiation protection quantity. Application of the effective dose equivalent for radiation protection assessments for patients is misleading and is not practical with regard to assessing an individual or collective radiation risk of patients. The quantity of expected harm would be better suited to this purpose. There is no need to express the radiation risk by a dose quantity, which means careless handling of good information. (orig./WU) [de

  12. Skin dose measurement with MICROSPEC-2 trademark

    International Nuclear Information System (INIS)

    Hsu, H.H.

    1997-01-01

    For many years, the Eberline HP-260 trademark beta detectors were used for skin dose measurements at Los Alamos National Laboratory. This detector does not measure the beta spectrum and the skin dose can only be determined if the contaminating radioactive isotope is known. A new product MICROSPEC-2 trademark, has been developed which consists of a small portable computer with a multichannel analyzer and a beta probe consisting of a phoswich detector. The system measures the beta spectrum and automatically folds in the beta fluence-to-dose conversion function to yield the skin dose

  13. Neutron spectrometry and determination of neutron ambient dose equivalents in different LINAC radiotherapy rooms

    Energy Technology Data Exchange (ETDEWEB)

    Domingo, C., E-mail: carles.domingo@uab.ca [Grup de Fisica de les Radiacions, Departament de Fisica. Edifici C, Campus UAB, Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain); Garcia-Fuste, M.J.; Morales, E.; Amgarou, K. [Grup de Fisica de les Radiacions, Departament de Fisica. Edifici C, Campus UAB, Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain); Terron, J.A. [Servicio de Radiofisica, Hospital Universitario Virgen Macarena. E- 41009 Sevilla. Spain (Spain); Rosello, J.; Brualla, L. [ERESA, Avda. Tres Cruces s/n. E-46014 Valencia (Spain); Nunez, L. [Servicio de Radiofisica, Hospital. Puerta de Hierro. E-28222 Majadahonda (Spain); Colmenares, R. [Serv. de Oncologia Radioterapica, Hosp. Ramon y Cajal, E-28049 Madrid (Spain); Gomez, F. [Dpto. de Particulas. Univ. de Santiago. E-15782 Santiago de Compostela. Spain (Spain); Hartmann, G.H. [DKFZ E0400 Im Neuenheimer Feld 280. D-69120 Heidelberg (Germany) (Germany); Sanchez-Doblado, F. [Servicio de Radiofisica, Hospital Universitario Virgen Macarena. E- 41009 Sevilla. Spain (Spain); Dpto. de Fisiologia Medica y Biofisica. Universidad de Sevilla. E-41009 Sevilla. Spain (Spain); Fernandez, F. [Grup de Fisica de les Radiacions, Departament de Fisica. Edifici C, Campus UAB, Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain); Consejo de Seguridad Nuclear, Justo Dorado 11 E-28040 Madrid (Spain)

    2010-12-15

    A project has been set up to study the effect on a radiotherapy patient of the neutrons produced around the LINAC accelerator head by photonuclear reactions induced by photons above {approx}8 MeV. These neutrons may reach directly the patient, or they may interact with the surrounding materials until they become thermalised, scattering all over the treatment room and affecting the patient as well, contributing to peripheral dose. Spectrometry was performed with a calibrated and validated set of Bonner spheres at a point located at 50 cm from the isocenter, as well as at the place where a digital device for measuring neutrons, based on the upset of SRAM memories induced by thermal neutrons, is located inside the treatment room. Exposures have taken place in six LINAC accelerators with different energies (from 15 to 23 MV) with the aim of relating the spectrometer measurements with the readings of the digital device under various exposure and room geometry conditions. The final purpose of the project is to be able to relate, under any given treatment condition and room geometry, the readings of this digital device to patient neutron effective dose and peripheral dose in organs of interest. This would allow inferring the probability of developing second malignancies as a consequence of the treatment. Results indicate that unit neutron fluence spectra at 50 cm from the isocenter do not depend on accelerator characteristics, while spectra at the place of the digital device are strongly influenced by the treatment room geometry.

  14. Neutron spectrometry and determination of neutron ambient dose equivalents in different LINAC radiotherapy rooms

    International Nuclear Information System (INIS)

    Domingo, C.; Garcia-Fuste, M.J.; Morales, E.; Amgarou, K.; Terron, J.A.; Rosello, J.; Brualla, L.; Nunez, L.; Colmenares, R.; Gomez, F.; Hartmann, G.H.; Sanchez-Doblado, F.; Fernandez, F.

    2010-01-01

    A project has been set up to study the effect on a radiotherapy patient of the neutrons produced around the LINAC accelerator head by photonuclear reactions induced by photons above ∼8 MeV. These neutrons may reach directly the patient, or they may interact with the surrounding materials until they become thermalised, scattering all over the treatment room and affecting the patient as well, contributing to peripheral dose. Spectrometry was performed with a calibrated and validated set of Bonner spheres at a point located at 50 cm from the isocenter, as well as at the place where a digital device for measuring neutrons, based on the upset of SRAM memories induced by thermal neutrons, is located inside the treatment room. Exposures have taken place in six LINAC accelerators with different energies (from 15 to 23 MV) with the aim of relating the spectrometer measurements with the readings of the digital device under various exposure and room geometry conditions. The final purpose of the project is to be able to relate, under any given treatment condition and room geometry, the readings of this digital device to patient neutron effective dose and peripheral dose in organs of interest. This would allow inferring the probability of developing second malignancies as a consequence of the treatment. Results indicate that unit neutron fluence spectra at 50 cm from the isocenter do not depend on accelerator characteristics, while spectra at the place of the digital device are strongly influenced by the treatment room geometry.

  15. Assessment of dose measurement uncertainty using RisøScan

    DEFF Research Database (Denmark)

    Helt-Hansen, J.; Miller, A.

    2006-01-01

    The dose measurement uncertainty of the dosimeter system RisoScan, office scanner and Riso B3 dosimeters has been assessed by comparison with spectrophotometer measurements of the same dosimeters. The reproducibility and the combined uncertainty were found to be approximately 2% and 4%, respectiv......The dose measurement uncertainty of the dosimeter system RisoScan, office scanner and Riso B3 dosimeters has been assessed by comparison with spectrophotometer measurements of the same dosimeters. The reproducibility and the combined uncertainty were found to be approximately 2% and 4......%, respectively, at one standard deviation. The subroutine in RisoScan for electron energy measurement is shown to give results that are equivalent to the measurements with a scanning spectrophotometer. (c) 2006 Elsevier Ltd. All rights reserved....

  16. Calculated organ equivalent doses for individuals in a sitting posture above a contaminated ground and a PET imaging room.

    Science.gov (United States)

    Su, Lin; Han, Bin; Xu, X George

    2012-03-01

    In this paper, phantoms representing sitting postures were developed and implemented in the MCNPX code to perform dose calculations. For the ground contamination case, isotropic planar source of (137)Cs was used. The male sitting phantom received an effective dose rate of 37.73 nSv h(-1) for a contamination of 30 kBq m(-2). The gonadal equivalent dose of the male sitting phantom was 40 % larger than that from the standing phantom. For the positron emission tomography clinic, a point photon source with the energy of 511 keV was used. The gonadal equivalent dose of the male sitting phantom was 117 % larger than that for the standing phantom. For an 8-h day, the effective dose of the sitting phantom was 2.54 μSv for 550 MBq F-18. This study concludes that phantoms with realistic postures could and should be considered in organ equivalent dose calculations in certain environmental and medical dosimetry studies where accurate data are desired.

  17. Online Radiation Dose Measurement System for ATLAS experiment

    CERN Document Server

    Mandić, I; The ATLAS collaboration

    2012-01-01

    Particle detectors and readout electronics in the high energy physics experiment ATLAS at the Large Hadron Collider at CERN operate in radiation field containing photons, charged particles and neutrons. The particles in the radiation field originate from proton-proton interactions as well as from interactions of these particles with material in the experimental apparatus. In the innermost parts of ATLAS detector components will be exposed to ionizing doses exceeding 100 kGy. Energetic hadrons will also cause displacement damage in silicon equivalent to fluences of several times 10e14 1 MeV-neutrons per cm2. Such radiation doses can have severe influence on the performance of detectors. It is therefore very important to continuously monitor the accumulated doses to understand the detector performance and to correctly predict the lifetime of radiation sensitive components. Measurements of doses are important also to verify the simulations and represent a crucial input into the models used for predicting future ...

  18. Nuclear reaction measurements on tissue-equivalent materials and GEANT4 Monte Carlo simulations for hadrontherapy

    Science.gov (United States)

    De Napoli, M.; Romano, F.; D'Urso, D.; Licciardello, T.; Agodi, C.; Candiano, G.; Cappuzzello, F.; Cirrone, G. A. P.; Cuttone, G.; Musumarra, A.; Pandola, L.; Scuderi, V.

    2014-12-01

    When a carbon beam interacts with human tissues, many secondary fragments are produced into the tumor region and the surrounding healthy tissues. Therefore, in hadrontherapy precise dose calculations require Monte Carlo tools equipped with complex nuclear reaction models. To get realistic predictions, however, simulation codes must be validated against experimental results; the wider the dataset is, the more the models are finely tuned. Since no fragmentation data for tissue-equivalent materials at Fermi energies are available in literature, we measured secondary fragments produced by the interaction of a 55.6 MeV u-1 12C beam with thick muscle and cortical bone targets. Three reaction models used by the Geant4 Monte Carlo code, the Binary Light Ions Cascade, the Quantum Molecular Dynamic and the Liege Intranuclear Cascade, have been benchmarked against the collected data. In this work we present the experimental results and we discuss the predictive power of the above mentioned models.

  19. Evaluation of equivalent doses in 18F PET/CT using the Monte Carlo method with MCNPX code

    International Nuclear Information System (INIS)

    Belinato, Walmir; Santos, William Souza; Perini, Ana Paula; Neves, Lucio Pereira; Souza, Divanizia N.

    2017-01-01

    The present work used the Monte Carlo method (MMC), specifically the Monte Carlo NParticle - MCNPX, to simulate the interaction of radiation involving photons and particles, such as positrons and electrons, with virtual adult anthropomorphic simulators on PET / CT scans and to determine absorbed and equivalent doses in adult male and female patients

  20. Blood pressure measurements in the ankle are not equivalent to ...

    African Journals Online (AJOL)

    Background. Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. Objective. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically ...

  1. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    International Nuclear Information System (INIS)

    Braby, L. A.; Reece, W. D.; Hsu, W. H.

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation experiments. We have also developed 4.3 mm diameter ion chambers with both tissue equivalent and carbon walls for the purpose of measuring dose mean lineal energy due to all radiations and due to all radiations except neutrons, respectively. By adjusting the gas pressure in the ion chamber, it can be made to simulate tissue volumes from a few nanometers to a few millimeters in diameter. The charge is integrated for 0.1 seconds, and the resulting pulse height is recorded by a multi channel analyzer. The system has been used in a variety of photon and neutron radiation fields, and measured values of dose and dose mean lineal energy are consistent with values extrapolated from measurements made by other techniques at much lower dose rates. It is expected that this technique will prove to be much more reliable than extrapolations from measurements made at low dose rates because these low dose rate exposures generally do not accurately reproduce the attenuation and

  2. The distribution of committed dose equivalents to workers exposed to tritium in the luminising industry in the United Kingdom

    International Nuclear Information System (INIS)

    Hipkin, J.

    1977-01-01

    In the United Kingdom tritium has become almost the only radionuclide that is used in luminising. Two distinct methods of luminising are used, one involving the use of tritium gas and the other involving the use of tritium activated luminous paint. All major luminisers have voluntarily taken part in urine monitoring programmes. The analyses have been carried out by the National Radiological Protection Board and estimates of committed dose equivalent have been made from the results. The work presented is an analysis of the committed dose equivalents received by all the individuals monitored in the years 1974, 1975 and 1976. It is shown that doses follow, in general, a lognormal distribution modified only at the high dose end by what must be described as dose management. Further evidence for dose management is seen when the pattern of dose versus time are analysed for selected individuals. It is shown that the maximum permissible dose as recommended by the International Commission on Radiological Protection, is only rarely exceeded. It is also shown that there is a substantial difference in the degree of exposure between workers involved in gaseous tritium luminising and workers using paint luminising. A comparison is made between exposure in gaseous tritium luminising and exposure in another common use of gaseous tritium, ie. the filling of electronic devices with tritium gas. It is shown that exposure is very much less in the electronic device work

  3. Impact of the Fukushima nuclear accident on background radiation doses measured by control dosimeters in Japan.

    Science.gov (United States)

    Romanyukha, Alexander; King, David L; Kennemur, Lisa K

    2012-05-01

    After the 9.0 magnitude earthquake and subsequent massive tsunami on 11 March 2011 in Japan, several reactors at the Fukushima Daiichi Nuclear Power Plant suffered severe damage. There was immediate participation of U.S. Navy vessels and other United States Department of Defense (DoD) teams that were already in the area at the time of the disaster or arrived shortly thereafter. The correct determination of occupational dose equivalent requires estimation of the background dose component measured by control dosimeters, which is subsequently subtracted from the total dose equivalent measured by personal dosimeters. The purpose of the control dosimeters is to determine the amount of radiation dose equivalent that has accumulated on the dosimeter from background or other non-occupational sources while they are in transit or being stored. Given the release of radioactive material and potential exposure to radiation from the Fukushima Daiichi Nuclear Power Plant and the process by which the U.S. Navy calculates occupational exposure to ionizing radiation, analysis of pre- and post-event control dosimeters is warranted. Several hundred historical dose records from the Naval Dosimetry Center (NDC) database were analyzed and compared with the post-accident dose equivalent data of control dosimeters. As result, it was shown that the dose contribution of the radiation and released radiological materials from the Fukushima nuclear accident to background radiation doses is less than 0.375 μSv d for shallow and deep photon dose equivalent. There is no measurable effect on neutron background exposure. The latter has at least two important conclusions. First, the NDC can use doses measured by control dosimeters at issuing sites in Japan for determination of personnel dose equivalents; second, the dose data from control dosimeters prior to and after the Fukushima accident may be used to assist in dose reconstruction of non-radiological (non-badged) personnel at these locations.

  4. Monte Carlo simulations of the secondary neutron ambient and effective dose equivalent rates from surface to suborbital altitudes and low Earth orbit.

    Science.gov (United States)

    El-Jaby, Samy; Richardson, Richard B

    2015-07-01

    Occupational exposures from ionizing radiation are currently regulated for airline travel (Earth orbit (∼300-400 km). Aircrew typically receive between 1 and 6 mSv of occupational dose annually, while aboard the International Space Station, the area radiation dose equivalent measured over just 168 days was 106 mSv at solar minimum conditions. It is anticipated that space tourism vehicles will reach suborbital altitudes of approximately 100 km and, therefore, the annual occupational dose to flight crew during repeated transits is expected to fall somewhere between those observed for aircrew and astronauts. Unfortunately, measurements of the radiation environment at the high altitudes reached by suborbital vehicles are sparse, and modelling efforts have been similarly limited. In this paper, preliminary MCNPX radiation transport code simulations are developed of the secondary neutron flux profile in air from surface altitudes up to low Earth orbit at solar minimum conditions and excluding the effects of spacecraft shielding. These secondary neutrons are produced by galactic cosmic radiation interacting with Earth's atmosphere and are among the sources of radiation that can pose a health risk. Associated estimates of the operational neutron ambient dose equivalent, used for radiation protection purposes, and the neutron effective dose equivalent that is typically used for estimates of stochastic health risks, are provided in air. Simulations show that the neutron radiation dose rates received at suborbital altitudes are comparable to those experienced by aircrew flying at 7 to 14 km. We also show that the total neutron dose rate tails off beyond the Pfotzer maximum on ascension from surface up to low Earth orbit. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  5. Incorporating Measurement Non-Equivalence in a Cross-Study Latent Growth Curve Analysis.

    Science.gov (United States)

    Flora, David B; Curran, Patrick J; Hussong, Andrea M; Edwards, Michael C

    2008-10-01

    A large literature emphasizes the importance of testing for measurement equivalence in scales that may be used as observed variables in structural equation modeling applications. When the same construct is measured across more than one developmental period, as in a longitudinal study, it can be especially critical to establish measurement equivalence, or invariance, across the developmental periods. Similarly, when data from more than one study are combined into a single analysis, it is again important to assess measurement equivalence across the data sources. Yet, how to incorporate non-equivalence when it is discovered is not well described for applied researchers. Here, we present an item response theory approach that can be used to create scale scores from measures while explicitly accounting for non-equivalence. We demonstrate these methods in the context of a latent curve analysis in which data from two separate studies are combined to create a single longitudinal model spanning several developmental periods.

  6. The study of equivalent dose of uranium in long bean (V. U. Sesquipedalis) and the effect on human

    Energy Technology Data Exchange (ETDEWEB)

    Rashid, Nur Shahidah Abdul; Yoshandi, Tengku Mohammad; Majid, Sukiman Sarmania Amran Ab.; Mohamed, Faizal; Siong, Khoo Kok, E-mail: khoo@ukm.edu.my [School of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia (UKM), 43600 Bangi, Selangor (Malaysia)

    2016-01-22

    In the case of accidental release of Uranium-238 ({sup 238}U) radionuclides in a nuclear facility or in the environment, internal contamination by either acute or chronic exposure has the potential to induce both radiological and chemical toxic effects. A study was conducted to estimate the {sup 238}U radionuclide concentration in the long beans using Induced Coupled Mass Plasma-Spectrometry (ICP-MS). {sup 238}U radionuclide is a naturally occurring radioactive material that can be found in soil and can be transferred to the long bean (Vigna unguiculata subsp. Sesquapedalis) directly or indirectly via water or air. Kidney and liver are the major sites of deposition of {sup 238}U radionuclide. The obtained dose exposed in the liver and kidney is used to assess the safety level for public intake of {sup 238}U radionuclide from the consumption of long beans. The concentration of {sup 238}U radionuclide measured in long bean samples was 0.0226 ± 0.0009 mg/kg. Total activity of {sup 238}U radionuclide was 0.0044 ± 0.0002 Bq/day with the daily intake of 0.3545 ± 0.0143 µg/day and the annual committed effective dose due to ingestion of {sup 238}U radionuclide in long beans was 0.2230 ± 0.0087 µSv/year. The committed equivalent dose of {sup 238}U radionuclide from the assessment in the liver and kidney are 0.4198 ± 0.0165 nSv and 10.9335 ± 0.4288 nSv. The risk of cancer of {sup 238}U radionuclide was determined to be (86.0466 ± 3.3748) × 10-9. Thus, the results concluded that {sup 238}U radionuclide in local long beans was in the permitted level and safe to consume without posing any significant radiological threat to population.

  7. The study of equivalent dose of uranium in long bean (V. U. Sesquipedalis) and the effect on human

    International Nuclear Information System (INIS)

    Rashid, Nur Shahidah Abdul; Yoshandi, Tengku Mohammad; Majid, Sukiman Sarmania Amran Ab.; Mohamed, Faizal; Siong, Khoo Kok

    2016-01-01

    In the case of accidental release of Uranium-238 ( 238 U) radionuclides in a nuclear facility or in the environment, internal contamination by either acute or chronic exposure has the potential to induce both radiological and chemical toxic effects. A study was conducted to estimate the 238 U radionuclide concentration in the long beans using Induced Coupled Mass Plasma-Spectrometry (ICP-MS). 238 U radionuclide is a naturally occurring radioactive material that can be found in soil and can be transferred to the long bean (Vigna unguiculata subsp. Sesquapedalis) directly or indirectly via water or air. Kidney and liver are the major sites of deposition of 238 U radionuclide. The obtained dose exposed in the liver and kidney is used to assess the safety level for public intake of 238 U radionuclide from the consumption of long beans. The concentration of 238 U radionuclide measured in long bean samples was 0.0226 ± 0.0009 mg/kg. Total activity of 238 U radionuclide was 0.0044 ± 0.0002 Bq/day with the daily intake of 0.3545 ± 0.0143 µg/day and the annual committed effective dose due to ingestion of 238 U radionuclide in long beans was 0.2230 ± 0.0087 µSv/year. The committed equivalent dose of 238 U radionuclide from the assessment in the liver and kidney are 0.4198 ± 0.0165 nSv and 10.9335 ± 0.4288 nSv. The risk of cancer of 238 U radionuclide was determined to be (86.0466 ± 3.3748) × 10-9. Thus, the results concluded that 238 U radionuclide in local long beans was in the permitted level and safe to consume without posing any significant radiological threat to population

  8. Physical requirements for measurement of radiation dose and their relationship to personnel dose meter design and use

    International Nuclear Information System (INIS)

    Chabot, G.E. Jr.; Jimenez, M.A.; Skrable, K.W.

    1978-01-01

    This paper stems from the concerns of the authors with both the design of current personnel dose meters and the interpretation of dose information from them in light of the actual physical requirements to measure dose. These concerns have been reinforced and extended following a comparative study of the responses of particular TLD and film systems and as the result of a recent national survey on personnel dosimetry conducted by the authors. Among the major points discussed are the systems available for penetrating and shallow dose assessment, dose meter calibration, the measurement and interpretation of skin dose, and the deficiencies of neutron albedo dose meters for routine personnel use. Calibration considerations address the questions of whether or not a phantom should be used and the difference in interpretation of responses with and without a phantom; the relationship between calculated and measured doses; and electronic equilibrium considerations in the measurement of photon doses. Matters of importance in relation to skin dose measurement include techniques in use to interpret skin dose from dose meter response; the appropriateness of evaluation of the surface dose to the live skin layer versus the average dose to the live skin layer and the limitations and requirements on dose meter design with respect to the dose being evaluated; and the significance of dose meter response in relationship to currently used beta calibration standards. Regarding the use of TLD albedo type neutron dose meters currently available, considerations are extended to the strong energy spectral dependence of the dose meter response and the possibility of making significant over or underestimations of neutron dose equivalent, depending on the calibration techniques used and the spectral quality encountered. (author)

  9. Fluence to Dose Equivalent Conversion Coefficients for Evaluation of Accelerator Radiation Environments

    International Nuclear Information System (INIS)

    Thomas, Ralph H.; Zeman, Gary H.

    2001-01-01

    The derivation of a set of conversion functions for the expression of neutron fluence measurements in terms of Effective Dose, E, is described. Four functions in analytical form are presented, covering the neutron energy range from 2.5 10-8 to 10+4 MeV, for the interpretation of fluence measurements in the typical irradiation conditions experienced around high-energy proton accelerators such as the Bevatron. For neutron energies below 200 MeV the analytical functions were modeled after the ISO and ROT conversion coefficients in ICRU 57. For neutron energies above 200 MeV, the analytical function was derived from an analysis of recent published data. Sample calculations using either the analytical expressions or the tabulated conversion coefficients from which the analytical expressions are derived show agreement to better than plus/minus 5%

  10. Determination of the equivalent dose in mixed neutron-gamma fields using spectrophotometric readout method: A study on NIRR-1 and Am-Be source

    International Nuclear Information System (INIS)

    Kassimu, A.A.; Akpa, T.C.; Jonah, S. A.; Mallam, S. P.

    2007-01-01

    Aliquots of alanine powder were irradiated with neutrons from a 5 5Ci-Am-Be source in the inner and outer channels of the Nigeria Research Reactor 1 (NIRR-1) in the Centre for Energy Research and Training, Zaria. The aim is to use the radiation-induced free radicals to determine the dose from the neutron sources. The irradiated amino acid was dissolved in a solution containing ferrous ammonium sulphate and xylenol orange in 0.05N H 2 SO 4 (FX-solution). The free radicals oxidize the Fe -2 to Fe -3 , which forms a complex with xylenol orange. The complex absorbs strongly at wavelength of 525nm. The absorbance was measured using CECIL CE 1020 spectrophotometer. Results show that the equivalent dose rate for the Am-Be source which is mainly from thermal neutrons component was 81.5 mSv/hr and that of the NIRR-1 which is mainly from the gamma ray component were 1.54 1011Sv/hr and 3.09 1010 Sv/hr for the inner and outer channels respectively. This shows that the equivalent dose rate in the inner channel is 5 times that of the outer channel. The estimated number of radicals producing a unit equivalent dose (Sv) is 3.33 1012 and 1.67 1012 for the inner and the outer channels respectively. This is in agreement with the predicted thermal neutron flux ratio of 2:1 for the channels in the reactor

  11. Personal dose equivalent Hp(0.07) of medical personnel occupationally exposed to ionizing radiation during 2001-2011.

    Science.gov (United States)

    Papierz, Sylwia; Kacprzyk, Janusz; Kamiński, Zbigniew; Adamowicz, Małgorzata; Zmyślony, Marek

    2012-01-01

    The paper presents the results of the determinations of the personal dose equivalent Hp(0.07) received by medical employees of interventional radiology departments occupationally exposed to X and gamma rays in Poland in 2011, performed by the Nofer Institute of Occupational Medicine in Łódź. The results were compared with the data collected during the last decade. The dosimetric service provided for medical employees of interventional radiology departments occupationally exposed to ionizing radiation in terms of the personal dose equivalent Hp(0.07). In 2011, personal dosimetry Hp(0.07) determinations performed by the Nofer Institute of Occupational Medicine in Łódź covered 2017 workers employed in 159 medical laboratories. The determinations were performed using ring dosimeters equipped with thermoluminescence detectors according to the procedure accredited by the Polish Centre for Accreditation (document number AB 327). The determinations were carried out in one or two-month periods. Mean annual personal dose equivalent Hp(0.07) in 2011 was equal to 4.9 mSv (annual limit for Hp(0.07) is 500 mSv). The mean annual doses of Hp(0.07) varied from 7.6 mSv in 2001 to 5.6 mSv in 2010. In 2011, two cases of exceeding the annual dose limit of Hp(0.07) were reported. The results show that more than 95% of all examined annual doses did not exceed the level of 10 mSv. The comparison of the average annual doses and detailed distributions of the doses during the last few years suggests a stabilized level of occupational exposure and an acceptable level of radiological protection in interventional radiology departments monitored by NIOM in Łódź.

  12. A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations

    International Nuclear Information System (INIS)

    Turner, Adam C.; Zhang Di; Kim, Hyun J.; DeMarco, John J.; Cagnon, Chris H.; Angel, Erin; Cody, Dianna D.; Stevens, Donna M.; Primak, Andrew N.; McCollough, Cynthia H.; McNitt-Gray, Michael F.

    2009-01-01

    The purpose of this study was to present a method for generating x-ray source models for performing Monte Carlo (MC) radiation dosimetry simulations of multidetector row CT (MDCT) scanners. These so-called ''equivalent'' source models consist of an energy spectrum and filtration description that are generated based wholly on the measured values and can be used in place of proprietary manufacturer's data for scanner-specific MDCT MC simulations. Required measurements include the half value layers (HVL 1 and HVL 2 ) and the bowtie profile (exposure values across the fan beam) for the MDCT scanner of interest. Using these measured values, a method was described (a) to numerically construct a spectrum with the calculated HVLs approximately equal to those measured (equivalent spectrum) and then (b) to determine a filtration scheme (equivalent filter) that attenuates the equivalent spectrum in a similar fashion as the actual filtration attenuates the actual x-ray beam, as measured by the bowtie profile measurements. Using this method, two types of equivalent source models were generated: One using a spectrum based on both HVL 1 and HVL 2 measurements and its corresponding filtration scheme and the second consisting of a spectrum based only on the measured HVL 1 and its corresponding filtration scheme. Finally, a third type of source model was built based on the spectrum and filtration data provided by the scanner's manufacturer. MC simulations using each of these three source model types were evaluated by comparing the accuracy of multiple CT dose index (CTDI) simulations to measured CTDI values for 64-slice scanners from the four major MDCT manufacturers. Comprehensive evaluations were carried out for each scanner using each kVp and bowtie filter combination available. CTDI experiments were performed for both head (16 cm in diameter) and body (32 cm in diameter) CTDI phantoms using both central and peripheral measurement positions. Both equivalent source model types

  13. A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations.

    Science.gov (United States)

    Turner, Adam C; Zhang, Di; Kim, Hyun J; DeMarco, John J; Cagnon, Chris H; Angel, Erin; Cody, Dianna D; Stevens, Donna M; Primak, Andrew N; McCollough, Cynthia H; McNitt-Gray, Michael F

    2009-06-01

    The purpose of this study was to present a method for generating x-ray source models for performing Monte Carlo (MC) radiation dosimetry simulations of multidetector row CT (MDCT) scanners. These so-called "equivalent" source models consist of an energy spectrum and filtration description that are generated based wholly on the measured values and can be used in place of proprietary manufacturer's data for scanner-specific MDCT MC simulations. Required measurements include the half value layers (HVL1 and HVL2) and the bowtie profile (exposure values across the fan beam) for the MDCT scanner of interest. Using these measured values, a method was described (a) to numerically construct a spectrum with the calculated HVLs approximately equal to those measured (equivalent spectrum) and then (b) to determine a filtration scheme (equivalent filter) that attenuates the equivalent spectrum in a similar fashion as the actual filtration attenuates the actual x-ray beam, as measured by the bowtie profile measurements. Using this method, two types of equivalent source models were generated: One using a spectrum based on both HVL1 and HVL2 measurements and its corresponding filtration scheme and the second consisting of a spectrum based only on the measured HVL1 and its corresponding filtration scheme. Finally, a third type of source model was built based on the spectrum and filtration data provided by the scanner's manufacturer. MC simulations using each of these three source model types were evaluated by comparing the accuracy of multiple CT dose index (CTDI) simulations to measured CTDI values for 64-slice scanners from the four major MDCT manufacturers. Comprehensive evaluations were carried out for each scanner using each kVp and bowtie filter combination available. CTDI experiments were performed for both head (16 cm in diameter) and body (32 cm in diameter) CTDI phantoms using both central and peripheral measurement positions. Both equivalent source model types result in

  14. Need for quality dose measurements

    International Nuclear Information System (INIS)

    Forbes, J.L.

    1985-01-01

    Work procedures based upon dependable measurements have unquestionably reduced past exposures to a level that will produce few injuries in later years. Of the many legal issues that might be discussed with regard to instrument calibration, the two of present concern are the determination of cause, and the evidence (including expert testimony) submitted to that end. Although they are termed here legal issues, they are in fact highly technical problems which have recently become political footballs. Some background is discussed in order to understand how such legal/technical/political considerations are related to instrument calibration, the subject of this workshop

  15. Estimation of low-level neutron dose-equivalent rate by using extrapolation method for a curie level Am–Be neutron source

    International Nuclear Information System (INIS)

    Li, Gang; Xu, Jiayun; Zhang, Jie

    2015-01-01

    Neutron radiation protection is an important research area because of the strong radiation biological effect of neutron field. The radiation dose of neutron is closely related to the neutron energy, and the connected relationship is a complex function of energy. For the low-level neutron radiation field (e.g. the Am–Be source), the commonly used commercial neutron dosimeter cannot always reflect the low-level dose rate, which is restricted by its own sensitivity limit and measuring range. In this paper, the intensity distribution of neutron field caused by a curie level Am–Be neutron source was investigated by measuring the count rates obtained through a 3 He proportional counter at different locations around the source. The results indicate that the count rates outside of the source room are negligible compared with the count rates measured in the source room. In the source room, 3 He proportional counter and neutron dosimeter were used to measure the count rates and dose rates respectively at different distances to the source. The results indicate that both the count rates and dose rates decrease exponentially with the increasing distance, and the dose rates measured by a commercial dosimeter are in good agreement with the results calculated by the Geant4 simulation within the inherent errors recommended by ICRP and IEC. Further studies presented in this paper indicate that the low-level neutron dose equivalent rates in the source room increase exponentially with the increasing low-energy neutron count rates when the source is lifted from the shield with different radiation intensities. Based on this relationship as well as the count rates measured at larger distance to the source, the dose rates can be calculated approximately by the extrapolation method. This principle can be used to estimate the low level neutron dose values in the source room which cannot be measured directly by a commercial dosimeter. - Highlights: • The scope of the affected area for

  16. Measurement model equivalence in web- and paper-based surveys

    African Journals Online (AJOL)

    N. Martins is in the Department of Industrial and Organisational Psychology, University of South Africa. E-mail: ... settings and, of course, the general survey and survey research industry. The use of ...... Chi-square based fi t indices for invariance tests on measures of 'Operational issues and job satisfaction'. D e gre e s of fre.

  17. Determination of the neutron and photon dose equivalent at work places in nuclear facilities of Sweden. An SSI - EURADOS comparison exercise. Part 2: Evaluation

    International Nuclear Information System (INIS)

    Bartlett, D.; Drake, P.; Lindborg, L.; Klein, H.; Schmitz, Th.; Tichy, M.

    1999-06-01

    Various mixed neutron-photon fields at workplaces in the containment of pressurised water reactors and in the vicinity of transport containers with spent fuel elements were investigated with spectrometers and dosimeters. The spectral neutron fluences evaluated from measurements with multisphere systems were recommended to be used for the calculation of dosimetric reference values for comparison with the readings of the dosemeters applied simultaneously. It turned out that most of the moderator based area dosemeters overestimated, while the TEPC systems generally underestimated the ambient dose equivalent (DE) values of the rather soft neutron fields encountered at these workplaces. The discrepancies can, however, be explained on the basis of energy dependent responses of the instruments used. The ambient DE values obtained with recently developed area dosemeters based on superheated drop detectors and with track etch based personal dosemeters on phantoms, however, were in satisfying agreement with the reference data. Sets of personal dosemeters simultaneously irradiated on a phantom allowed to roughly estimate the directional dependence of the neutron fluence. Hence, personal and limiting dose equivalent quantities could also be calculated. The personal and ambient DE values were always conservative estimates of the limiting quantities. Unexpectedly, discrepancies were observed for photon DE data measured with GM counters and TEPC systems. The up to 50 % higher readings of the GM counters may be explained by a considerable contribution of high energy photons to the total photon dose equivalent, but photon spectrometry is necessary for final clarification

  18. Determination of the neutron and photon dose equivalent at work places in nuclear facilities of Sweden. An SSI - EURADOS comparison exercise. Part 2: Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Bartlett, D. [National Radiological Protection Board, Chilton (United Kingdom); Drake, P. [Vattenfall AB, Vaeroebacka (Sweden); Lindborg, L. [Swedish Radiation Protection Inst., Stockholm (Sweden); Klein, H. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Schmitz, Th. [Forschungszentrum Juelich GmbH, Juelich (Germany); Tichy, M

    1999-06-01

    Various mixed neutron-photon fields at workplaces in the containment of pressurised water reactors and in the vicinity of transport containers with spent fuel elements were investigated with spectrometers and dosimeters. The spectral neutron fluences evaluated from measurements with multisphere systems were recommended to be used for the calculation of dosimetric reference values for comparison with the readings of the dosemeters applied simultaneously. It turned out that most of the moderator based area dosemeters overestimated, while the TEPC systems generally underestimated the ambient dose equivalent (DE) values of the rather soft neutron fields encountered at these workplaces. The discrepancies can, however, be explained on the basis of energy dependent responses of the instruments used. The ambient DE values obtained with recently developed area dosemeters based on superheated drop detectors and with track etch based personal dosemeters on phantoms, however, were in satisfying agreement with the reference data. Sets of personal dosemeters simultaneously irradiated on a phantom allowed to roughly estimate the directional dependence of the neutron fluence. Hence, personal and limiting dose equivalent quantities could also be calculated. The personal and ambient DE values were always conservative estimates of the limiting quantities. Unexpectedly, discrepancies were observed for photon DE data measured with GM counters and TEPC systems. The up to 50 % higher readings of the GM counters may be explained by a considerable contribution of high energy photons to the total photon dose equivalent, but photon spectrometry is necessary for final clarification.

  19. Thermally assisted OSL application for equivalent dose estimation; comparison of multiple equivalent dose values as well as saturation levels determined by luminescence and ESR techniques for a sedimentary sample collected from a fault gouge

    Science.gov (United States)

    Şahiner, Eren; Meriç, Niyazi; Polymeris, George S.

    2017-02-01

    Equivalent dose estimation (De) constitutes the most important part of either trap-charge dating techniques or dosimetry applications. In the present work, multiple, independent equivalent dose estimation approaches were adopted, using both luminescence and ESR techniques; two different minerals were studied, namely quartz as well as feldspathic polymineral samples. The work is divided into three independent parts, depending on the type of signal employed. Firstly, different De estimation approaches were carried out on both polymineral and contaminated quartz, using single aliquot regenerative dose protocols employing conventional OSL and IRSL signals, acquired at different temperatures. Secondly, ESR equivalent dose estimations using the additive dose procedure both at room temperature and at 90 K were discussed. Lastly, for the first time in the literature, a single aliquot regenerative protocol employing a thermally assisted OSL signal originating from Very Deep Traps was applied for natural minerals. Rejection criteria such as recycling and recovery ratios are also presented. The SAR protocol, whenever applied, provided with compatible De estimations with great accuracy, independent on either the type of mineral or the stimulation temperature. Low temperature ESR signals resulting from Al and Ti centers indicate very large De values due to bleaching in-ability, associated with large uncertainty values. Additionally, dose saturation of different approaches was investigated. For the signal arising from Very Deep Traps in quartz saturation is extended almost by one order of magnitude. It is interesting that most of De values yielded using different luminescence signals agree with each other and ESR Ge center has very large D0 values. The results presented above highly support the argument that the stability and the initial ESR signal of the Ge center is highly sample-dependent, without any instability problems for the cases of quartz resulting from fault gouge.

  20. The biologically equivalent dose BED - Is the approach for calculation of this factor really a reliable basis?

    International Nuclear Information System (INIS)

    Jensen, J.M.; Zimmermann, J.

    2000-01-01

    To predict the effect on tumours in radiotherapy, especially relating to irreversible effects, but also to realize the retrospective assessment the so called L-Q-model is relied on at present. Internal specific organ parameters, such as α, β, γ, T p , T k , and ρ, as well as external parameters, so as D, d, n, V, and V ref , were used for determination of the biologically equivalent dose BED. While the external parameters are determinable with small deviations, the internal parameters depend on biological varieties and dispersons: In some cases the lowest value is assumed to be Δ=±25%. This margin of error goes on to the biologically equivalent dose by means of the principle of superposition of errors. In some selected cases (lung, kidney, skin, rectum) these margins of error were calculated exemplarily. The input errors especially of the internal parameters cause a mean error Δ on the biologically equivalent dose and a dispersion of the single fraction dose d dependent on the organ taking into consideration, of approximately 8-30%. Hence it follows only a very critical and cautious application of those L-Q-algorithms in expert proceedings, and in radiotherapy more experienced based decisions are recommended, instead of acting only upon simple two-dimensional mechanistic ideas. (orig.) [de

  1. The interpretation of quartz optically stimulated luminescence equivalent dose versus time plots

    International Nuclear Information System (INIS)

    Bailey, R.M.

    2000-01-01

    Numerical modelling has shown that the form of the quartz OSL shine plateau (hereafter 'D e (t)-plot') is influenced by the effects of phototransferred TL in the ∼110 deg. C region. It is suggested also that the presence of multiple OSL components (as described by Partial bleaching and the decay form characteristics of quartz OSL. Radiat. Meas., 27, 123-136. The form of the optically stimulated luminescence signal of quartz: implications of dating. Unpublished PhD thesis, University of London) affects the form of the D e (t)-plot. Laboratory measurements of a fully reset and artificially dosed sample yielded non-flat D e (t)-plots, the deviation being greater for the larger of the two simulated palaeodoses, in accordance with theoretical predictions. It is suggested that the so-called 'shine plateau' test is of limited use in assessing the bleaching history of quartz sediments

  2. Cross-Ethnicity Measurement Equivalence of Family Coping for Breast Cancer Survivors

    Science.gov (United States)

    Lim, Jung-won; Townsend, Aloen

    2012-01-01

    Objective: The current study examines the equivalence of a measure of family coping, the Family Crisis Oriented Personal Evaluation scales (F-COPES), in Chinese American and Korean American breast cancer survivors (BCS). Methods: Factor structure and cross-ethnicity equivalence of the F-COPES were tested using structural equation modeling with 157…

  3. Breast internal dose measurements in a physical thoracic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Silva, S.D.; Oliveira, M.A.; Castro, A.L.S.; Dias, H.G.; Nogueira, L.B.; Campos, T.P.R., E-mail: sadonatosilva@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Hospital das Clinicas de Uberlandia, MG (Brazil). Departamento de Oncologia; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Anatomia e Departamento de Imagem

    2017-10-01

    Radiotherapy is a cancer treatment intended to deposit the entire prescribed dose homogeneously into a target volume in order to eliminate the tumor and to spare the surrounding healthy tissues. This paper aimed to provide a dosimetric comparison between the treatment planning system (TPS) ECLIPSE from Varian Medical Systems and the internal dosimetric measurements in a breast phantom. The methodology consisted in performing a 3D conformal radiotherapy planning with two tangential opposite parallel fields applied to the synthetic breast in a thoracic phantom. The irradiation was reproduced in the Varian Linear accelerator, model SL - 20 Precise, 6 MV energy. EBT2 Radiochromic films, placed into the glandular equivalent tissue of the breast, were used to measure the spatial dose distribution. The absorbed dose was compared to those values predicted by the treatment planning system; besides, the dosimetric uncertainties were analyzed. The modal absorbed dose was in agreement with the prescribed value of 180 cGy, although few high dose points between 180 and 220 cGy were detected. The findings suggested a non-uniform dose distribution in the glandular tissue of the synthetic breast, similar to those found in the TPS, associated with the irregular anatomic breast shape and presence of inhomogeneities next to the thoracic wall generated by the low lung density. (author)

  4. A Study on intelligent measurement of nuclear explosion equivalent in atmosphere

    International Nuclear Information System (INIS)

    Wang Desheng; Wu Xiaohong

    1999-01-01

    Measurement of nuclear explosion equivalent in atmosphere is an important subject for nuclear survey. Based on the relations between nuclear explosion equivalent and the minimum illuminance time of light radiation from nuclear explosion. The method of RC differential valley time detection and mean-time taking is presented the method, using a single-chip computer as a intelligent part, can realize intelligent measurement of minimum illuminance time with high reliability and low power consumption. This method provides a practical mean for quick, accurate and reliable measurement of nuclear explosion equivalent in atmosphere

  5. A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations

    Science.gov (United States)

    Turner, Adam C.; Zhang, Di; Kim, Hyun J.; DeMarco, John J.; Cagnon, Chris H.; Angel, Erin; Cody, Dianna D.; Stevens, Donna M.; Primak, Andrew N.; McCollough, Cynthia H.; McNitt-Gray, Michael F.

    2009-01-01

    The purpose of this study was to present a method for generating x-ray source models for performing Monte Carlo (MC) radiation dosimetry simulations of multidetector row CT (MDCT) scanners. These so-called “equivalent” source models consist of an energy spectrum and filtration description that are generated based wholly on the measured values and can be used in place of proprietary manufacturer’s data for scanner-specific MDCT MC simulations. Required measurements include the half value layers (HVL1 and HVL2) and the bowtie profile (exposure values across the fan beam) for the MDCT scanner of interest. Using these measured values, a method was described (a) to numerically construct a spectrum with the calculated HVLs approximately equal to those measured (equivalent spectrum) and then (b) to determine a filtration scheme (equivalent filter) that attenuates the equivalent spectrum in a similar fashion as the actual filtration attenuates the actual x-ray beam, as measured by the bowtie profile measurements. Using this method, two types of equivalent source models were generated: One using a spectrum based on both HVL1 and HVL2 measurements and its corresponding filtration scheme and the second consisting of a spectrum based only on the measured HVL1 and its corresponding filtration scheme. Finally, a third type of source model was built based on the spectrum and filtration data provided by the scanner’s manufacturer. MC simulations using each of these three source model types were evaluated by comparing the accuracy of multiple CT dose index (CTDI) simulations to measured CTDI values for 64-slice scanners from the four major MDCT manufacturers. Comprehensive evaluations were carried out for each scanner using each kVp and bowtie filter combination available. CTDI experiments were performed for both head (16 cm in diameter) and body (32 cm in diameter) CTDI phantoms using both central and peripheral measurement positions. Both equivalent source model types

  6. Medical irradiation and the use of the ''effective dose equivalent'' concept

    International Nuclear Information System (INIS)

    Persson, B.R.R.

    1980-01-01

    The aim of this paper is to demonstrate the use of the effective dose for all kinds of medical irradiation. In order to estimate the 'somatic effective dose' the weighting factors recommended by ICRP 26 have been separated into those for somatic effects and for genetic effects. Calculation of the effective dose in diagnostic radiology procedures must consider the various technical parameters which determine the absorbed dose in the various organs, i.e. beam quality, typical entrance dose and the number of films of each view. Knowledge about these parameters is not always well established and therefore the effective dose estimates are very uncertain. The average dose absorbed by various organs in the case of administration of radionuclides to the body depends to a much higher degree on biological parameters than in the case of external irradiation. In contrast to the variability and lack of reliability of biological data, the physical methods for internal dose calculation are quite elaborate. However, these methods have to be extended to involve the target dose from the radioactivity distributed within the remaining parts of the body. An attempt was made to estimate the somatic effective dose for the most common diagnostic X-ray and nuclear medicine procedures. This would make it possible to compare the risk of X-ray and nuclear medicine techniques on a more equitable basis. The collective effective dose from medical irradiation is estimated for various countries on the basis of reported statistical data. (H.K.)

  7. Analytical evaluation of dose measurement of critical accident at SILENE (Contract research)

    CERN Document Server

    Nakamura, T; Tonoike, K

    2003-01-01

    Institute for Radioprotection and Nuclear Safety (IRSN) and the OECD Nuclear Energy Agency (NEA) jointly organized SILENE Accident Dosimetry Intercomparison Exercise to intercompare the dose measurement systems of participating countries. Each participating country carried out dose measurements in the same irradiation field, and the measurement results were mutually compared. The participated in the exercise to measure the doses of gamma rays and neutron from SILENE by using thermoluminescence dosimeters (TLD's) and an alanine dosimeter. In this examination, the derived evaluation formulae for obtaining a tissue-absorbed dose from measured value (ambient dose equivalent) of TLD for neutron. We reported the tissue-absorbed dose computed using this evaluation formula to OECD/NEA. TLD's for neutron were irradiated in the TRACY facility to verify the evaluation formulae. The results of TLD's were compared with the calculations of MCNP and measurements with alanine dose meter. We found that the ratio of the dose b...

  8. Toxicokinetics of Deltamethrin: Dosage Dependency, Vehicle Effects, and Low-Dose Age-Equivalent Dosimetry in Rats.

    Science.gov (United States)

    Mortuza, Tanzir; Chen, Chen; White, Catherine A; Cummings, Brian S; Muralidhara, Srinivasa; Gullick, Darren; Bruckner, James V

    2018-03-01

    There is increasing concern that infants and children may be at increased risk of neurological effects of pyrethroids, the most widely used class of insecticide. The objectives of this investigation were to (1) characterize the dose-dependent toxicokinetics (TK) of deltamethrin (DLM) for exposures ranging from environmentally relevant to acutely toxic; (2) determine the influence of an aqueous versus oil vehicle on oral absorption and bioavailability; and (3) determine whether DLM exhibits low-dose, age-equivalent internal dosimetry. Serial arterial plasma samples were obtained for 72 h from adult, male Sprague Dawley rats given 0.05-5.0 mg DLM/kg as an oral bolus in corn oil (CO). DLM exhibited linear, absorption rate-limited TK. Increases in maximum plasma concentration (Cmax) and AUC∘∞ were directly proportional to the dose. Oral bioavailability was quite limited. The vehicle and its volume had modest effect on the rate and extent of systemic absorption in adult rats. Postnatal day (PND) 15, 21, and 90 (adult) rats received 0.10, 0.25, or 0.50 mg DLM/kg orally in CO and were sacrificed periodically for plasma, brain, and liver collection. Age-dependent differences between PND 15 and 90 plasma Cmax and AUC∘24 values progressively diminished as the dose decreased, but there was a lack of low dose age equivalence in these brain and liver dosimeters. Other maturational factors may account for the lack of the low-dose age equivalence in brain and liver. This investigation provides support for the premise that the relatively low metabolic capacity of immature subjects may be adequate to effectively eliminate trace amounts of DLM and other pyrethroids from the plasma.

  9. Radiation Dose Measurement Using Chemical Dosimeters

    International Nuclear Information System (INIS)

    Lee, Min Sun; Kim, Eun Hee; Kim, Yu Ri; Han, Bum Soo

    2010-01-01

    The radiation dose can be estimated in various ways. Dose estimates can be obtained by either experiment or theoretical analysis. In experiments, radiation impact is assessed by measuring any change caused by energy deposition to the exposed matter, in terms of energy state (physical change), chemical production (chemical change) or biological abnormality (biological change). The chemical dosimetry is based on the implication that the energy deposited to the matter can be inferred from the consequential change in chemical production. The chemical dosimetry usually works on the sample that is an aqueous solution, a biological matter, or an organic substance. In this study, we estimated absorbed doses by quantitating chemical changes in matter caused by radiation exposure. Two different chemical dosimeters, Fricke and ECB (Ethanol-Chlorobenzene) dosimeter, were compared in several features including efficacy as dose indicator and effective dose range

  10. Photo neutron dose equivalent rate in 15 MV X-ray beam from a Siemens Primus Linac.

    Science.gov (United States)

    Ghasemi, A; Pourfallah, T Allahverdi; Akbari, M R; Babapour, H; Shahidi, M

    2015-01-01

    Fast and thermal neutron fluence rates from a 15 MV X-ray beams of a Siemens Primus Linac were measured using bare and moderated BF3 proportional counter inside the treatment room at different locations. Fluence rate values were converted to dose equivalent rate (DER) utilizing conversion factors of American Association of Physicist in Medicine's (AAPM) report number 19. For thermal neutrons, maximum and minimum DERs were 3.46 × 10(-6) (3 m from isocenter in +Y direction, 0 × 0 field size) and 8.36 × 10(-8) Sv/min (in maze, 40 × 40 field size), respectively. For fast neutrons, maximum DERs using 9" and 3" moderators were 1.6 × 10(-5) and 1.74 × 10(-5) Sv/min (2 m from isocenter in +Y direction, 0 × 0 field size), respectively. By changing the field size, the variation in thermal neutron DER was more than the fast neutron DER and the changes in fast neutron DER were not significant in the bunker except inside the radiation field. This study showed that at all points and distances, by decreasing field size of the beam, thermal and fast neutron DER increases and the number of thermal neutrons is more than fast neutrons.

  11. A point-kernel shielding code for calculations of neutron and secondary gamma-ray 1cm dose equivalents: PKN

    International Nuclear Information System (INIS)

    Kotegawa, Hiroshi; Tanaka, Shun-ichi

    1991-09-01

    A point-kernel integral technique code, PKN, and the related data library have been developed to calculate neutron and secondary gamma-ray dose equivalents in water, concrete and iron shields for neutron sources in 3-dimensional geometry. The comparison between calculational results of the present code and those of the 1-dimensional transport code ANISN = JR, and the 2-dimensional transport code DOT4.2 showed a sufficient accuracy, and the availability of the PKN code has been confirmed. (author)

  12. Organ dose measurement using Optically Stimulated Luminescence Detector (OSLD) during CT examination

    Science.gov (United States)

    Yusuf, Muhammad; Alothmany, Nazeeh; Abdulrahman Kinsara, Abdulraheem

    2017-10-01

    This study provides detailed information regarding the imaging doses to patient radiosensitive organs from a kilovoltage computed tomography (CT) scan procedure using OSLD. The study reports discrepancies between the measured dose and the calculated dose from the ImPACT scan, as well as a comparison with the dose from a chest X-ray radiography procedure. OSLDs were inserted in several organs, including the brain, eyes, thyroid, lung, heart, spinal cord, breast, spleen, stomach, liver and ovaries, of the RANDO phantom. Standard clinical scanning protocols were used for each individual site, including the brain, thyroid, lung, breast, stomach, liver and ovaries. The measured absorbed doses were then compared with the simulated dose obtained from the ImPACT scan. Additionally, the equivalent doses for each organ were calculated and compared with the dose from a chest X-ray radiography procedure. Absorbed organ doses measured by OSLD in the RANDO phantom of up to 17 mGy depend on the organ scanned and the scanning protocols used. A maximum 9.82% difference was observed between the target organ dose measured by OSLD and the results from the ImPACT scan. The maximum equivalent organ dose measured during this experiment was equal to 99.899 times the equivalent dose from a chest X-ray radiography procedure. The discrepancies between the measured dose with the OSLD and the calculated dose from the ImPACT scan were within 10%. This report recommends the use of OSLD for measuring the absorbed organ dose during CT examination.

  13. Measurement of the dose distribution around patients injected during different scintigraphic procedures: about 145 patients

    International Nuclear Information System (INIS)

    Mertz, L.; Blanche, J.M.; Bouche, E.; Malzac, D.; Khayat, E.; Brunot, B.; Constantinesco, A.

    1998-01-01

    To take care for medical attention or examinations of injected patients for scintigraphy poses the problem of dose equivalents received the medical personnel. In order to reply in a rational way to hospital personnel giving care to these patients, measures of dose distribution have been realized around 145 injected patients in the frame of diagnostic examinations (scintigraphy) during the period from june to july 1997 in the service of nuclear medicine. From these measurements, the dose equivalents have been calculated in the more frequent care situations. The work was limited to the only risk of internal exposure. (N.C.)

  14. Ionization chamber for high dose measurements

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de Araujo

    2005-01-01

    Industrial gamma irradiators facilities are designed for processing large amounts of products, which are exposed to large doses of gamma radiation. The irradiation, in industrial scale, is usually carried out in a dynamic form, where the products go through a 60 Co gamma source with activity of TBq to P Bq (k Ci to MCi). The dose is estimated as being directly proportional to the time that the products spend to go through the source. However, in some situations, mainly for research purposes or for validation of customer process following the ISO 11137 requirements, it is required to irradiate small samples in a static position with fractional deliver doses. The samples are put inside the irradiation room at a fixed distance from the source and the dose is usually determined using dosimeters. The dose is only known after the irradiation, by reading the dosimeter. Nevertheless, in the industrial irradiators, usually different kinds of products with different densities go through between the source and the static position samples. So, the dose rate varies in function of the product density. A suitable methodology would be to monitor the samples dose in real time, measuring the dose on line with a radiation detector, which would improve the dose accuracy and avoid the overdose. A cylindrical ionization chamber of 0.9 cm 3 has been developed for high-doses real-time monitoring, during the sample irradiation at a static position in a 60 Co gamma industrial plant. Nitrogen and argon gas at pressure of 10 exp 5 Pa (1 bar) was utilized to fill the ionization chamber, for which an appropriate configuration was determined to be used as a detector for high-dose measurements. To transmit the signal generated in the ionization chamber to the associated electronic and processing unit, a 20 m mineral insulated cable was welded to the ionization chamber. The signal to noise ratio produced by the detector was about 100. The dosimeter system was tested at a category I gamma

  15. Study of the equivalent dose distribution in organs and tissues using periapical odontological radiography

    International Nuclear Information System (INIS)

    Santos, H.F.S.; Cipeli, J.F.; Fortes, M.A.B.; Federico, C.A.

    2017-01-01

    In this article presents a study of the doses obtained in periapical odontological radiography in main tissues of the head, using thermoluminescent dosemeters of type TLD-700H applied to a anthropomorphic simulator. The results indicate that the skin and salivary glands received the highest doses and the risk of calculated injury was 1.44 x 10 -6 Sv -1 per radiograph

  16. Equity-regarding poverty measures: differences in needs and the role of equivalence scales

    OpenAIRE

    Udo Ebert

    2010-01-01

    The paper investigates the definition of equity-regarding poverty measures when there are different household types in the population. It demonstrates the implications of a between-type regressive transfer principle for poverty measures, for the choice of poverty lines, and for the measurement of living standard. The role of equivalence scales, which are popular in empirical work on poverty measurement, is clarified.

  17. Calculation of neutron fluence to dose equivalent conversion coefficients using GEANT4; Calculo de coeficientes de fluencia de neutrons para equivalente de dose individual utilizando o GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Rosane M.; Santos, Denison de S.; Queiroz Filho, Pedro P. de; Mauricio, CLaudia L.P.; Silva, Livia K. da; Pessanha, Paula R., E-mail: rosanemribeiro@oi.com.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    Fluence to dose equivalent conversion coefficients provide the basis for the calculation of area and personal monitors. Recently, the ICRP has started a revision of these coefficients, including new Monte Carlo codes for benchmarking. So far, little information is available about neutron transport below 10 MeV in tissue-equivalent (TE) material performed with Monte Carlo GEANT4 code. The objective of this work is to calculate neutron fluence to personal dose equivalent conversion coefficients, H{sub p} (10)/Φ, with GEANT4 code. The incidence of monoenergetic neutrons was simulated as an expanded and aligned field, with energies ranging between thermal neutrons to 10 MeV on the ICRU slab of dimension 30 x 30 x 15 cm{sup 3}, composed of 76.2% of oxygen, 10.1% of hydrogen, 11.1% of carbon and 2.6% of nitrogen. For all incident energy, a cylindrical sensitive volume is placed at a depth of 10 mm, in the largest surface of the slab (30 x 30 cm{sup 2}). Physic process are included for neutrons, photons and charged particles, and calculations are made for neutrons and secondary particles which reach the sensitive volume. Results obtained are thus compared with values published in ICRP 74. Neutron fluence in the sensitive volume was calculated for benchmarking. The Monte Carlo GEANT4 code was found to be appropriate to calculate neutron doses at energies below 10 MeV correctly. (author)

  18. Assessment of ambient dose equivalent rate performance of an automatic survey meter as an instrument to quantify the presence of radiation in soils

    CERN Document Server

    Yoshimura, E M; Okuno, E

    2002-01-01

    Those who work in radiation protection are faced with various quantities that were created to account for the effects of ionizing radiation in the human body. As far as the experimental point of view is concerned, each available equipment is planned to measure a distinct quantity, for a specific radiation protection application, and it is not always clear which one it is. This paper shows a series of tests, planned and applied to a portable gamma ray spectrometer, in order to assure that the monitoring low dose levels of radiation with it is reliable. The equipment is fully automated and does not allow modifications of the conversion factors from counts to ambient dose equivalent. It is therefore necessary to assure that the values provided by the equipment are correct and refer to the actual situation one expects to find in practice. The system is based on an NaI(Tl) scintillation detector, mounted with its electronics in a portable case, suitable for field measurements. It measures ambient dose equivalent r...

  19. Surface dose extrapolation measurements with radiographic film

    International Nuclear Information System (INIS)

    Butson, Martin J; Cheung Tsang; Yu, Peter K N; Currie, Michael

    2004-01-01

    Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown that the surface percentage dose can be estimated within ±3% of parallel plate ionization chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10 cm, 20 cm and 30 cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. The corresponding parallel plate ionization chamber measurements are 16%, 27% and 37%, respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. (note)

  20. Evaluation of the effective equivalent dose in the general public due to the discharge of uranium in groundwater

    International Nuclear Information System (INIS)

    Gordon, A.M.P.L.; Jacomino, V.M.F.

    1989-12-01

    Some facilities available at IPEN-CNEN/SP may discharge uranium in their liquid effluents. The uranium contents of these effluents are analyzed by photometry or fluorimetry, and according to the results obtained a decision is made, by the Environmental Monitoring Division, upon their discharge to the environment. In 1988 a total activity of 3.66x10 9 Bq of uranium was discharge in a volume of approximately 30 m 3 . The effective equivalent dose in the general public was evaluated by making a conservative assumption that all the liquid effluents containing uranium are discharged directly to the soil reaching the groundwater. The dose calculation was carried out by using a generic model which described the transport of radionuclides in the groundwater. In order to be conservative it was also assumed that the critical pathway is the direct in gestion of water through hypothetical wells around the Institute. Conservative assumptions were also made in the characterization of the local aquifer parameters such as vertical and longitudinal dispersivity, effective porosity of the soil, hydraulic conductivity etc., in roder to overestimate the effective equivalent dose. The result obtained, of 5.3x10 -10 mSv/a is far below the dose limit for the public adopted by the Radiological Protection Board. The derived limit for the discharge was also evaluated, using the same model, giving a result of 3.6x10 13 Bq/a. (author) [pt

  1. Diagnostic accuracy of chest X-ray dose-equivalent CT for assessing calcified atherosclerotic burden of the thoracic aorta.

    Science.gov (United States)

    Messerli, Michael; Giannopoulos, Andreas A; Leschka, Sebastian; Warschkow, René; Wildermuth, Simon; Hechelhammer, Lukas; Bauer, Ralf W

    2017-12-01

    To determine the value of ultralow-dose chest CT for estimating the calcified atherosclerotic burden of the thoracic aorta using tin-filter CT and compare its diagnostic accuracy with chest direct radiography. A total of 106 patients from a prospective, IRB-approved single-centre study were included and underwent standard dose chest CT (1.7 ± 0.7 mSv) by clinical indication followed by ultralow-dose CT with 100 kV and spectral shaping by a tin filter (0.13 ± 0.01 mSv) to achieve chest X-ray equivalent dose in the same session. Two independent radiologists reviewed the CT images, rated image quality and estimated presence and extent of calcification of aortic valve, ascending aorta and aortic arch. Conventional radiographs were also reviewed for presence of aortic calcifications. The sensitivity of ultralow-dose CT for the detection of calcifications of the aortic valve, ascending aorta and aortic arch was 93.5, 96.2 and 96.2%, respectively, compared with standard dose CT. The sensitivity for the detection of thoracic aortic calcification was significantly lower on chest X-ray (52.3%) compared with ultralow-dose CT (p < 0.001). A reliable estimation of calcified atherosclerotic burden of the thoracic aorta can be achieved with modern tin-filter CT at dose values comparable to chest direct radiography. Advances in knowledge: Our findings suggest that ultralow-dose CT is an excellent tool for assessing the calcified atherosclerotic burden of the thoracic aorta with higher diagnostic accuracy than conventional chest radiography and importantly without the additional cost of increased radiation dose.

  2. Ambient dose measurement in some CT departments in Khartoum State

    International Nuclear Information System (INIS)

    Mohammed, S. A. H.

    2012-09-01

    Computerized Tomography (CT) is now one of the most important radiological examinations world wide.The frequency of CT examinations is increasing rapidly from 2% of all radiological examinations in some countries a decade age to 10-15% now. During the imaging procedure, staff may expose to a significant dose. Therefore, ambient dose measurement is important in the shortage of regular personal monitoring in sudan. This study intended to evaluate the ambient dose at some CT departments (Medical Military hospital, Alamal National Hospital, Elnelin Diagnostic Center and Modern Medical Centre). These departments were equipped with daul, 16 and 64 multi detector CT machines. A survey meter (Radios) was used to measure ambient doses in three locations: Doors, Control Rooms and Adjacent Rooms. The ambient dose equivalent (scatter dose) was measured at various distances from the isocenter of the CT unit at various angles to establish isodose cartography. The mean and range of radiation at control room is 10.00-0.20 and mean (7.05μSv/hr,) reception 1.0-0 (0.40) and doors 4.00-100.00 (73.5) for height 1 meter above the ground. For height 2 meters at control room 0-10.00 (6,75), reception 0-90.00 (30) at door 9.00-90.00 (49.50). This study confirms that low levels of radiation dose are received by staff during CT imaging and these levels are within safe limits as prescribed by the national and international regulations. (Author)

  3. Personal dose equivalent conversion coefficients for neutron fluence over the energy range of 20-250 MeV.

    Science.gov (United States)

    Olsher, R H; McLean, T D; Justus, A L; Devine, R T; Gadd, M S

    2010-03-01

    Monte Carlo simulations were performed to extend existing neutron personal dose equivalent fluence-to-dose conversion coefficients to an energy of 250 MeV. Presently, conversion coefficients, H(p,slab)(10,alpha)/Phi, are given by ICRP-74 and ICRU-57 for a range of angles of radiation incidence (alpha = 0, 15, 30, 45, 60 and 75 degrees ) in the energy range from thermal to 20 MeV. Standard practice has been to base operational dose quantity calculations 20 MeV. Both light and heavy ions (HIs) (carbon, nitrogen and oxygen recoil nuclei) were transported down to a lower energy limit (1 keV for light ions and 5 MeV for HIs). Track energy below the limit was assumed to be locally deposited. For neutron tracks slab phantom.

  4. An overview of equivalent doses in eye lens of occupational radiation workers in medical, industrial and nuclear areas

    International Nuclear Information System (INIS)

    Lima, A.R.; Silva, F.C.A. da; Hunt, J.G.

    2013-01-01

    Some epidemiological evidences were recently reviewed by the ICRP and it was suggested that, for the eye lens, the absorbed dose threshold for induction of late detriments is about 0.5 Gy. On this basis, on 2011, the ICRP has recommended changes to the occupational dose limit in planned exposure situations, reducing the eye lens dose equivalent limit of 150 mSv to 20 mSv per year, on average, during the period of 5 years, with exposure not exceeding 50 mSv in a single year. Following the ICRP recommendation, the Brazilian Commission of Nuclear Energy (CNEN) adopted immediately the new limit to the eyes lens. This study aimed to show an overview about the doses in eye lens of occupational radiation workers in situations of planned exposures in the medical, industrial and nuclear areas, emphasizing the greatest radiological risks applications. It was observed that there are some limitations, such as example, to use individual monitor calibrated on Hp(3), to assess the equivalent dose in the eye lens. This limitation obstructs some experimental studies and monitoring of the levels of radiation received in the eye lens of radiation workers. Recent studies have showed that the lenses of eyes monitoring of workers, mainly in the planned exposure, must be follow-up. However, such researches were obtained only in medical exposures, mainly in interventional medicine procedures. Studies with planned exposure on nuclear and industrial areas are really needed and will be very important due to the new recommended by ICRP dose limits. (author)

  5. Measuring pacemaker dose: A clinical perspective

    Energy Technology Data Exchange (ETDEWEB)

    Studenski, Matthew T., E-mail: matthew.studenski@jeffersonhospital.org [Department of Radiation Oncology at the Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States); Xiao Ying; Harrison, Amy S. [Department of Radiation Oncology at the Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States)

    2012-07-01

    Recently in our clinic, we have seen an increased number of patients presenting with pacemakers and defibrillators. Precautions are taken to develop a treatment plan that minimizes the dose to the pacemaker because of the adverse effects of radiation on the electronics. Here we analyze different dosimeters to determine which is the most accurate in measuring pacemaker or defibrillator dose while at the same time not requiring a significant investment in time to maintain an efficient workflow in the clinic. The dosimeters analyzed here were ion chambers, diodes, metal-oxide-semiconductor field effect transistor (MOSFETs), and optically stimulated luminescence (OSL) dosimeters. A simple phantom was used to quantify the angular and energy dependence of each dosimeter. Next, 8 patients plans were delivered to a Rando phantom with all the dosimeters located where the pacemaker would be, and the measurements were compared with the predicted dose. A cone beam computed tomography (CBCT) image was obtained to determine the dosimeter response in the kilovoltage energy range. In terms of the angular and energy dependence of the dosimeters, the ion chamber and diode were the most stable. For the clinical cases, all the dosimeters match relatively well with the predicted dose, although the ideal dosimeter to use is case dependent. The dosimeters, especially the MOSFETS, tend to be less accurate for the plans, with many lateral beams. Because of their efficiency, we recommend using a MOSFET or a diode to measure the dose. If a discrepancy is observed between the measured and expected dose (especially when the pacemaker to field edge is <10 cm), we recommend analyzing the treatment plan to see whether there are many lateral beams. Follow-up with another dosimeter rather than repeating multiple times with the same type of dosimeter. All dosimeters should be placed after the CBCT has been acquired.

  6. Estimating average glandular dose by measuring glandular rate in mammograms

    International Nuclear Information System (INIS)

    Goto, Sachiko; Azuma, Yoshiharu; Sumimoto, Tetsuhiro; Eiho, Shigeru

    2003-01-01

    The glandular rate of the breast was objectively measured in order to calculate individual patient exposure dose (average glandular dose) in mammography. By employing image processing techniques and breast-equivalent phantoms with various glandular rate values, a conversion curve for pixel value to glandular rate can be determined by a neural network. Accordingly, the pixel values in clinical mammograms can be converted to the glandular rate value for each pixel. The individual average glandular dose can therefore be calculated using the individual glandular rates on the basis of the dosimetry method employed for quality control in mammography. In the present study, a data set of 100 craniocaudal mammograms from 50 patients was used to evaluate our method. The average glandular rate and average glandular dose of the data set were 41.2% and 1.79 mGy, respectively. The error in calculating the individual glandular rate can be estimated to be less than ±3%. When the calculation error of the glandular rate is taken into consideration, the error in the individual average glandular dose can be estimated to be 13% or less. We feel that our method for determining the glandular rate from mammograms is useful for minimizing subjectivity in the evaluation of patient breast composition. (author)

  7. Do English and Chinese EQ-5D versions demonstrate measurement equivalence? an exploratory study

    Directory of Open Access Journals (Sweden)

    Ng Swee-Cheng

    2003-04-01

    Full Text Available Abstract Background Although multiple language versions of health-related quality of life instruments are often used interchangeably in clinical research, the measurement equivalence of these versions (especially using alphabet vs pictogram-based languages has rarely been assessed. We therefore investigated the measurement equivalence of English and Chinese versions of the EQ-5D, a widely used utility-based outcome instrument. Methods In a cross-sectional study, either EQ-5D version was administered to consecutive outpatients with rheumatic diseases. Measurement equivalence of EQ-5D item responses and utility and visual analog scale (EQ-VAS scores between these versions was assessed using multiple regression models (with and without adjusting for potential confounding variables, by comparing the 95% confidence interval (95%CI of score differences between these versions with pre-defined equivalence margins. An equivalence margin defined a magnitude of score differences (10% and 5% of entire score ranges for item responses and utility/EQ-VAS scores, respectively which was felt to be clinically unimportant. Results Sixty-six subjects completed the English and 48 subjects the Chinese EQ-5D. The 95%CI of the score differences between these versions overlapped with but did not fall completely within pre-defined equivalence margins for 4 EQ-5D items, utility and EQ-VAS scores. For example, the 95%CI of the adjusted score difference between these EQ-5D versions was -0.14 to +0.03 points for utility scores and -11.6 to +3.3 points for EQ-VAS scores (equivalence margins of -0.05 to +0.05 and -5.0 to +5.0 respectively. Conclusion These data provide promising evidence for the measurement equivalence of English and Chinese EQ-5D versions.

  8. Polystyrene calorimeter for electron beam dose measurements

    DEFF Research Database (Denmark)

    Miller, A.

    1995-01-01

    Calorimeters from polystrene have been constructed for dose measurement at 4-10 MeV electron accelerators. These calorimeters have been used successfully for a few years, and polystyrene calorimeters for use at energies down to 1 MeV and being tested. Advantage of polystyrene as the absorbing...

  9. Measurement and evaluation of internal dose

    International Nuclear Information System (INIS)

    Lee, Tae Young; Chang, S. Y.; Lee, J. I.; Song, M. Y.

    2006-01-01

    This report describes the contents and results for implementation of internal radiation monitoring programme, measurement of uranium present in lung by lung counter and assessment of committed effective dose for radiation workers of the KNFC. The aim of radiation protection was achieved by implementing this activity

  10. Measurement of personal equivalent dose Hp(3) during procedures involving in positron emission tomography; Medida del equivalente de dosis personal en cristalino Hp(3) durante los procedimientos asociados a la tomografía por emisión de positrones

    Energy Technology Data Exchange (ETDEWEB)

    Guiu Souto, J.; Sánchez García, M.; Vázquez, R.; Pardo Montero, J.; Pombar Cameán, M.

    2017-11-01

    The aim of the present study consists to determinate the personal equivalent dose Hp(3) at eye lens during the procedures involved in positron emission tomography. We have monitored the nurse's staff which is responsible of handling and dispensing 18F. We characterize the relevant stages as the preparation, the transport and the administration of monodose syringes in terms of occupational dose. We observed that the preparation presents a major contribution to the occupational doses than the other stages. In addition, during those stage there is a correlation between the dose increments and handling activity. To establish the eye lens dose we use the following dosimetry set: a direct readout solid state dosimeter for general purposes calibrated at Hp(10) and a set of thermolumiscent dosimeters specific for 18F calibrated at Hp(3). Finally, for the dose intercomparison between above dosimeters we obtain a correction factor by Monte Carlo. The eye lens dose, with a value of 2.8 ± 0.4 mSv/yr, results more critical than the dose obtained in other locations, as extremities. [Spanish] El propósito del presente trabajo consiste en la determinación del equivalente de dosis personal Hp(3) en cristalino durante los procedimientos asociados a la tomografía por emisión de positrones. Se ha monitorizado al personal de enfermería que realiza las tareas de manipulación y dispensación del 18F. Se ha realizado un estudio caracterizando la dosis en las etapas más relevantes del procedimiento: la preparación manual de las jeringuillas, el transporte de las mismas y su posterior administración al paciente. Se observó que la preparación es la etapa que más contribuye a la dosis ocupacional, además durante dicha etapa se observa una clara correlación entre el incremento de dosis y la actividad manipulada. Para determinar la dosis en cristalino se ha utilizado el siguiente equipo dosimétrico: un detector de estado sólido de lectura directa de propósito general

  11. The risk equivalent of an exposure to-, versus a dose of radiation

    International Nuclear Information System (INIS)

    Bond, V.P.

    1986-01-01

    The long-term potential carcinogenic effects of low-level exposure (LLE) are addressed. The principal point discussed is linear, no-threshold dose-response curve. That the linear no-threshold, or proportional relationship is widely used is seen in the way in which the values for cancer risk coefficients are expressed - in terms of new cases, per million persons exposed, per year, per unit exposure or dose. This implies that the underlying relationship is proportional, i.e., ''linear, without threshold''. 12 refs., 9 figs., 1 tab

  12. Effective doses in the radial gamma radiation field near a point source: gender difference and deviation from the personal dose equivalent

    International Nuclear Information System (INIS)

    Chang, Jai Kwon; Lee, Jai Ki

    1997-01-01

    The individual dose equivalent, H p , effective dose, E, and gender specific effective dose, E m , and E f , were evaluated using the male and female phantoms of MIRD type located in the radial gamma radiation field near a point source. The point sources were placed at the distances of 15, 40 and 100 cm in front of the body at different heights. Two radionuclides, 137 Cs and 131 I, were selected for the illustrative examples. In terms of the gender specific effective doses, E f is higher than E m with a few exceptions, e.g. the case where the point source is at the height of reproductive organs, but the differences from the sex- averaged values are not significant enough to justify use of gender specific dose conversion factors for the radial gamma field. The ratios H p /E were in the range of 1 to 3 depending on the source and dosimeter positions when the dosimeter is worn on the front surface of the torso covering from chest to lower abdomen, but varied from 0.34 to 6.5 in extreme cases. When it is assumed that the typical handling procedure of radioactive source material and the typical dosimeter position (on the chest) be respected, the dosimeters calibrated against the broad parallel field appear to provide estimates with acceptable errors for the effective dose of workers exposed to radial broad gamma field around a point source

  13. Estimating Radiation Risk from Total Effective Dose Equivalent (TEDE) – ISCORS Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2003-01-01

    The Interagency Steering Committee on Radiation Standards (ISCORS) recently issued guidance on calculating radiation risk estimates from dose. An EH-41 Information Brief discussing the method and the ISCORS technical report, “A Method for Estimating Radiation Risk from TEDE,” are attached. Exposure-to-risk estimates have been tabulated in a 1999 report, Cancer Risk Coefficients for Environmental Exposure to Radionuclides, Federal Guidance Report No. 13. This report was distributed within DOE previously for limited review and comment and it is now available on the EH-41 web site: http://www.eh.doe.gov/oepa. Although the approach used in Federal Guidance Report # 13 is more appropriate for circumstances where a radiation risk assessment is required than the dose-to-risk approach in the attached report, it is applicable only when the intake of an inhaled or ingested radionuclide is known or the radionuclide concentration in air, water or on the ground is known. In many cases, doses (specifically the TEDE) are calculated directly from computer codes and estimates of the intake or radionuclide concentrations are not directly available. The attached document is intended to facilitate the estimation of risk in those situations where dose (TEDE) is calculated directly.

  14. Comparison of Out-Of-Field Neutron Equivalent Doses in Scanning Carbon and Proton Therapies for Cranial Fields

    DEFF Research Database (Denmark)

    Athar, B.; Henker, K.; Jäkel, O.

    2010-01-01

    Purpose: The purpose of this analysis is to compare the secondary neutron lateral doses from scanning carbon and proton beam therapies. Method and Materials: We simulated secondary neutron doses for out-of-field organs in an 11-year old male patient. Scanned carbon and proton beams were simulated......, absorbed neutron doses to tonsils and pharynx close to the field-edge were found to be 5x10-4 mSv/GyE and 4x10-4 mSv/GyE, respectively. Whereas, neutron equivalent doses to tonsils and pharynx were estimated to be 0.57mSv/GyE and 0.55 mSv/GyE in scanned proton therapy, respectively. In heavy ion carbon...... beams neutrons produced inside the patient are emitted at small angles, predominantly in the forward direction, whereas in proton therapy, neutrons are emitted more isotropic. Therefore the absorbed neutron doses in carbon therapy lateral to the field edge are smaller compared to the corresponding...

  15. Requirements for beta gamma dose measurement

    International Nuclear Information System (INIS)

    Alvarez, J.L.

    1987-01-01

    The fundamental requirements for dose measurement are discussed for designing a detector that is capable of measuring both beta and gamma dose at a desired depth. A detector that can measure a broad energy range of beta and gamma must, essentially, respond as tissue at the depth of interest. Tissue response requires that photon absorption and electron stopping power be the same or parallel to tissue over the energy range, that back scatter be similar, as well as, having the proper amount of back scatter material, and that the detector have the same angular and depth response as tissue. These requirements restrict both material and configuration selection or require knowledge of the incident spectrum. 10 refs., 6 figs

  16. Equivalent Dose Rate 1 Meter from Neuroendocrine Tumor Patients Exiting the Nuclear Medicine Department After Undergoing Imaging.

    Science.gov (United States)

    Zhang-Yin, Jules; Dirand, Anne-Sophie; Sasanelli, Myriam; Corrégé, Gwenaelle; Peudon, Aude; Kiffel, Thierry; Nataf, Valérie; Clerc, Jérôme; Montravers, Françoise; Talbot, Jean-Noël

    2017-08-01

    123 I-metaiodobenzylguanidine (MIBG) and 111 In-pentetrotide SPECT have been used for functional imaging of neuroendocrine tumors (NETs) for the last 2 decades. More recently, PET/CT imaging with 18 F-FDG, 18 F-fluorodihydroxyphenylalanine (FDOPA), and 68 Ga somatostatin-receptor ligands in NETs has been expanding. A literature search could find no direct measurements of the dose rate from NET patients exiting the nuclear medicine department after undergoing PET/CT with 18 F-FDOPA or 68 Ga-DOTATOC, a somatostatin analog. Methods: We measured the dose rates from 93 NET patients on leaving the department after undergoing PET/CT or SPECT/CT in our centers. In total, 103 paired measurements of equivalent dose rate at 1 m (EDR-1m) from the sternum and urinary bladder were obtained. The detector faced the sternum or bladder and was 1 m away from and directly in front of the patient. The practice for exiting the department differed according to whether the patient had been referred for PET/CT or for SPECT/CT. PET/CT patients were discharged after imaging, whereas SPECT/CT patients left the department earlier, just after radiopharmaceutical injection. Results: The median administered activity was 122 MBq in 53 68 Ga-DOTATOC PET/CT studies, 198 MBq in 15 18 F-FDOPA PET/CT studies, and 176 MBq in 13 18 F-FDG PET/CT studies. The corresponding median EDR-1m was 4.8, 9.5, and 8.8 μSv/h, respectively, facing the sternum, and 5.1, 10.1, and 9.5 μSv/h, respectively, facing the bladder. The median administered activity was 170 MBq in 12 111 In-pentetreotide SPECT/CT studies and 186 MBq in 10 123 I-MIBG SPECT/CT studies. The corresponding median EDR-1m was 9.4, and 4.9 μSv/h, respectively, at the level of the sternum, and 9.3 and 4.7 μSv/h, respectively, at the level of the bladder. The EDR-1m was less than 20 μSv/h in all patients. Thus, when exiting the nuclear medicine department, the NET patients injected with 68 Ga-DOTATOC or 123 I MIBG emitted an average EDR-1m roughly

  17. Evaluation of equivalent and effective dose by KAP for patient and orthopedic surgeon in vertebral compression fracture surgery

    International Nuclear Information System (INIS)

    Santos, Felipe A.; Galeano, Diego C.; Santos, William S.; Silva, Ademir X.; Souza, Susana O.; Carvalho Júnior, Albérico B.

    2017-01-01

    Clinical scenarios were virtually modeled to estimate both the equivalent and effective doses normalized by KAP (Kerma Area Product) to vertebra compression fracture surgery in patient and surgeon. This surgery is known as kyphoplasty and involves the use of X-ray equipment, the C-arm, which provides real-time images to assist the surgeon in conducting instruments inserted into the patient and in the delivery of surgical cement into the fractured vertebra. The radiation transport code used was MCNPX (Monte Carlo N-Particle eXtended) and a pair of UFHADM (University of Florida Hybrid ADult Male) virtual phantoms. The developed scenarios allowed us to calculate a set of equivalent dose (H T ) and effective dose (E) for patients and surgeons. In additional, the same scenario was calculated KAP in the tube output and was used for calculating conversion coefficients (E/KAP and H T /KAP). From the knowledge of the experimental values of KAP and the results presented in this study, it is possible to estimate absolute values of effective doses for different exposure conditions. In this work, we developed scenarios with and without the surgical table with the purpose of comparison with the existing data in the literature. The absence of the bed in the scenario promoted a percentage absolute difference of 56% in the patient effective doses in relation to scenarios calculated with a bed. Regarding the surgeon, the use of the personal protective equipment (PPE) reduces between 75% and 79% the effective dose and the use of the under table shield (UTS) reduces the effective dose of between 3% and 7%. All these variations emphasize the importance of the elaboration of virtual scenarios that approach the actual clinical conditions generating E/KAP and H T /KAP closer to the actual values. - Highlights: • Virtual scenarios of vertebra compression fracture surgery. • MC simulations using virtual anthropomorphic phantoms and surgical setups. • Estimation of E/KAP and H T /KAP

  18. Ionizing radiation population doses at Sao Paulo city, Brazil: open-pit gamma dose measurement

    International Nuclear Information System (INIS)

    Oliveira, Raimundo Enoch Rodrigues

    2001-01-01

    The effects of ionizing radiation to the human beings are well known for high and intermediate doses. As far as low level) radiation doses are concerned, there is no consensus. In order to get a better understanding of such effects it is necessary to assess the low doses with better accuracy. In this work, it was made an estimate of the annual ambient dose equivalent (H * (10)) to which the people are exposed in the city of Sao Paulo. Until now there are no data about it available in the literature. For the purpose of this evaluation, a map with various routes covering the largest and more representative area of the city was designed. The choice of points for data collection was made taking into account mainly the occupancy of the region. A portable gamma spectrometry system was used. It furnishes the rate of H * (10) and the measured gamma spectrum (in the range from 50 to 1670 keV) in the place of interest. The measurements were performed in a short time interval, since the gamma radiation arrives from a great extent of soil. Each measurement was done 1 m above the soil during 300 s. The rates of H * (10) varied from 33.1 to 152.3 nSv.h -1 , net values, obtained after subtraction of the cosmic rays contribution. The standard deviation was 22 n Sv.h -1 for an average for the city of Sao Paulo of 96.1(24) nSv.h -1 . In addition, average values of H * (10) rates for the city Health Divisions were calculated. Those values are not statistically equivalent and the whole set of data could not be treated as one, as the statistical Student test indicated a non homogeneity of the group of data. Hence it is necessary the accomplishment of a more detailed survey in order to verify the origin of the discrepancy. The mean value of H * (10) rate obtained for the city of Sao Paulo as converted to effective dose. in order to be compared with other places results It could be noticed that the annual average of effective dose for the city of Sao Paulo, 0.522(13) mSv, is superior to

  19. In vivo measurement of urethral dose profiles

    International Nuclear Information System (INIS)

    Toye, W.C.; Royal Melbourne Institute of Technology,; Duchesne, G.M.; Das, K.R.; Cee, A.; Mameghan, H.; Johnston, P.N.

    2001-01-01

    Full text: Quality assurance becomes a critical requirement when radiographs are routinely used in planning of treatments. In HDR prostate brachytherapy, the surrounding organs at risk of complications are the bladder and the rectum. However, of particular concern is the urethra that runs centrally through the prostate gland, as an unavoidably high dose can occur in the central region in order to achieve a minimum peripheral dose to a small target volume. Although high urethral doses have previously been related to increased urinary symptoms, some recent studies have not found such a correlation. The aim of this study was firstly, to identify dosimetric indicators of urethral morbidity following HDR prostate brachytherapy (4F x of 5.0 Gy), and secondly, to test the validity of calculated dose values. The in vivo measurements utilised a TLD (LiF:Mg,Ti) train formed by loading eight TLD rods alternating with 1,0 cm brass spacers into a fine plastic flexible tube. The length and diameter of plastic tubing was approximately 45cm and 0.15cm respectively, while the train length was 11.8 cm from the tip of the tube. The TLD train was placed into the central lumen of an 18 F three-way urethral catheter prior to its insertion. Significant urinary morbidity was defined prospectively as a score of a total of 3 or more points for severity from 5 symptoms categories. The five symptoms evaluated were hesitancy, frequency/nocturia, dysuria, haematuria and incontinence. The introduction of in vivo measurements to enhance the existing dosimetric analysis may be required to fully test the quantitative relationships (e.g. dose-volume ratios). Placement of TLDs within the urethra results in measurements whose accuracy is unaffected by internal organ motion as the hollow urethra must move with the prostate. The dose recorded by the TLDs is determined independently of the predictive algorithm used by the treatment planning system, and prostate location errors (e.g. due to image

  20. 50 CFR 648.107 - Conservation equivalent measures for the summer flounder fishery.

    Science.gov (United States)

    2010-10-01

    ... to the recreational fishing measures of this part and registered in states whose fishery management... 50 Wildlife and Fisheries 8 2010-10-01 2010-10-01 false Conservation equivalent measures for the summer flounder fishery. 648.107 Section 648.107 Wildlife and Fisheries FISHERY CONSERVATION AND...

  1. New equivalent-electrical circuit model and a practical measurement method for human body impedance.

    Science.gov (United States)

    Chinen, Koyu; Kinjo, Ichiko; Zamami, Aki; Irei, Kotoyo; Nagayama, Kanako

    2015-01-01

    Human body impedance analysis is an effective tool to extract electrical information from tissues in the human body. This paper presents a new measurement method of impedance using armpit electrode and a new equivalent circuit model for the human body. The lowest impedance was measured by using an LCR meter and six electrodes including armpit electrodes. The electrical equivalent circuit model for the cell consists of resistance R and capacitance C. The R represents electrical resistance of the liquid of the inside and outside of the cell, and the C represents high frequency conductance of the cell membrane. We propose an equivalent circuit model which consists of five parallel high frequency-passing CR circuits. The proposed equivalent circuit represents alpha distribution in the impedance measured at a lower frequency range due to ion current of the outside of the cell, and beta distribution at a high frequency range due to the cell membrane and the liquid inside cell. The calculated values by using the proposed equivalent circuit model were consistent with the measured values for the human body impedance.

  2. Didactic revision of the operative magnitudes system ICRU for the evaluation of the equivalent dose in radiation external fields

    International Nuclear Information System (INIS)

    Alvarez R, J. T.

    2014-10-01

    In this work is presented in a didactic way the operative magnitudes system ICRU, showing as these magnitudes carry out an appropriate estimate of the effective equivalent doses H E and the effective dose. The objective is to present the basic concepts of the dosimetry for radiation external fields with purposes of radiological protection, because the assimilation lack and technological development of this dosimetric magnitudes system has persisted for near 50 years, in terms of practice of the radiological protection in Mexico. Also, this system is an essential part of safety basic standards of the IAEA and ICRP recommendations 26, 60, 74 and 103, as well as of the ICRU 25, 39, 43, 51 and 57. (Author)

  3. A new Monte Carlo program for calculations of dose distributions within tissue equivalent phantoms irradiated from π--meson beams

    International Nuclear Information System (INIS)

    Przybilla, G.

    1980-11-01

    The present paper reports on the structure and first results from a new Monte Carlo programme for calculations of energy distributions within tissue equivalent phantoms irradiated from π - -beams. Each pion or generated secondary particle is transported until to the complete loss of its kinetic energy taking into account pion processes like multiple Coulomb scattering, pion reactions in flight and absorption of stopped pions. The code uses mainly data from experiments, and physical models have been added only in cases of lacking data. Depth dose curves for a pensil beam of 170 MeV/c within a water phantom are discussed as a function of various parameters. Isodose contours are plotted resulting from a convolution of an extended beam profile and the dose distribution of a pencil beams. (orig.) [de

  4. Sensitivity analysis concerning dose equivalents associated with the disposal of radioactive wastes in deep geological formations

    International Nuclear Information System (INIS)

    Lewi, J.; Mejon-Goula, M.J.; Cernes, A.; Brun-Yaba, C.

    1989-11-01

    Even if dose calculations may be performed for nuclear waste repositories in deep geological formations, it is unavoidable that the credibility of the obtained results might be affected by huge incertitudes in connection in particular with a lack of precise knowledge of the different components of the performed evaluations (scenarios, models, parameters). In consequence, this paper presents the approach adopted at the CEA/IPSN for performing sensitivity analysis and some obtained results [fr

  5. Development and use of a fifteen year-old equivalent mathematical phantom for internal dose calculations

    International Nuclear Information System (INIS)

    Jones, R.M.; Poston, J.W.; Hwang, J.L.; Jones, T.D.; Warner, G.G.

    1976-06-01

    The existence of a phantom based on anatomical data for the average fifteen-year-old provides for a proficient means of obtaining estimates of absorbed dose for children of that age. Dimensions representative of an average fifteen-year-old human, obtained from various biological and medical research, were transformed into a mathematical construct of idealized shapes of the exterior, skeletal system, and internal organs of a human. The idealization for an average adult presently in use by the International Commission on Radiological Protection was used as a basis for design. The mathematical equations describing the phantom were developed to be readily adaptable to present-day methods of dose estimation. Typical exposure situations in nuclear medicine have previously been modeled for existing phantoms. With no further development of the exposure model necessary, adaptation to the fifteen-year-old phantom demonstrated the utility of the design. Estimates of absorbed dose were obtained for the administration of two radiopharmaceuticals, /sup 99m/Tc-sulfur colloid and /sup 99m/Tc-DMSA

  6. Influence of length of interval between pulses in PDR brachytherapy (PDRBT on value of Biologically Equivalent Dose (BED in healthy tissues

    Directory of Open Access Journals (Sweden)

    Tomasz Piotrowski

    2010-07-01

    Full Text Available Purpose: Different PDR treatment schemas are used in clinical practice, however optimal length of interval between pulses still remains unclear. The aim of this work was to compare value of BED doses measured in surrounded healthy tissues according to different intervals between pulses in PDRBT. Influence of doses optimization on BED values was analyzed.Material and methods: Fifty-one patients treated in Greater Poland Cancer Centre were qualified for calculations.Calculations of doses were made in 51 patients with head and neck cancer, brain tumor, breast cancer, sarcoma, penis cancer and rectal cancer. Doses were calculated with the use of PLATO planning system in chosen critical points in surrounded healthy tissues. For all treatment plans the doses were compared using Biologically Equivalent Dose formula.Three interval lengths (1, 2 and 4 hours between pulses were chosen for calculations. For statistical analysis Friedman ANOVA test and Kendall ratio were used.Results: The median value of BED in chosen critical points in healthy tissues was statistically related to the length of interval between PDR pulses and decreased exponentially with 1 hour interval to 4 hours (Kendall = from 0.48 to 1.0; p = from 0.002 to 0.00001.Conclusions: Prolongation of intervals between pulses in PDR brachytherapy was connected with lower values of BED doses in healthy tissues. It seems that longer intervals between pulses reduced the risk of late complications, but also decreased the tumour control. Furthermore, optimization influenced the increase of doses in healthy tissues.

  7. Transfer factor of sup 131 I from the fallout to human thyroid dose equivalent after the Chernobyl accident

    Energy Technology Data Exchange (ETDEWEB)

    Beno, M.; Hrabina, J. (Research Inst. of Preventive and Clinical Medicine, Bratislava (Czechoslovakia)); Mikulecky, M. (Comenius Univ., Bratislava (Czechoslovakia). 1. Medical Clinic)

    1992-04-01

    A similar pattern of variation with time in observed maxima of daily dose equivalent rates in human thyroids (TD-{mu}Sv.d{sup -1}) and of daily fallout radioactivities (FR-kBq.m{sup -2}) has been found after the Chernobyl accident. An estimate of the time-lag between the maxima in TD lines and the preceding FR peaks was made of about seven days for adult and nine days for juveniles. Applying this time-lag it was possible to estimate transfer factors from the fallout to thyroid dose equivalent: The highest estimated values were 221 {mu}Sv/kBq.m{sup -2} for adult and 641 {mu}Sv/kBq.m{sup -2} for juvenile thyroids. These values differ from those published by UNSCEAR (United Nations 1988), which have been calculated for various regions of Czechoslovakia, from ingestion and inhalation intake estimates. A broad variation of transfer factor values could be expected to result from such transfer calculations using ingestion and inhalation estimates. The findings also support the concept of a need for prolonged iodine prophylaxy after emissions of radioiodine into the environment. (orig.).

  8. Development of a Reference System for the determination of the personal dose equivalent and the constancy of X- Ray beams

    International Nuclear Information System (INIS)

    Vivolo, Vitor

    2006-01-01

    A reference system for the determination of the personal dose equivalent, Hp (10), and a quality control program of X-ray equipment used In radioprotection require the periodic verification of the X-ray beams constancy. In this work, two parallel-plate ionization chambers were developed with inner electrodes of different materials, and inserted into PMMA slab phantoms. One ionization chamber was developed with inner carbon electrodes and the other with inner aluminium electrodes. The two ionization chambers can be used as a Tandem system. The different energy response of the two ionization chambers allowed the development of the Tandem system that is very useful for the checking of the constancy of beam qualities. Standard intermediary energy X-ray beams (from 48 keV to 118 keV), radioprotection level, were established through the development of a dosimetric methodology and the analysis of their physical parameters. The ionization chambers were studied in relation to their operational characteristics, and they were calibrated in X-ray beams (radioprotection, diagnostic radiology, mammography and radiotherapy levels) in accordance to international recommendations. They presented good performance. The determination procedure of personal dose equivalent, Hp (10), was established. (author)

  9. Increased cortical porosity is associated with daily, not weekly, administration of equivalent doses of teriparatide.

    Science.gov (United States)

    Zebaze, Roger; Takao-Kawabata, Ryoko; Peng, Yu; Zadeh, Ali Ghasem; Hirano, Kyoko; Yamane, Hiroshi; Takakura, Aya; Isogai, Yukihiro; Ishizuya, Toshinori; Seeman, Ego

    2017-06-01

    The pharmacokinetic profile of parathyroid hormone (PTH) determines its effects on bone resorption and formation. When administered intermittently, anabolic effects are favored in comparison with the continuous treatment. Among the intermittent treatment regimens, lower frequency of administration may have a lower effect on bone remodeling. We therefore hypothesized that weekly administration of teriparatide will produce less increase in intracortical remodeling and porosity than reported using daily treatment. We treated 17 female New Zealand white rabbits aged 6months for 1month with teriparatide [human PTH(1-34)] as follows. (i) Vehicle-treated Control (n=4); (ii) 20μg/kg daily (n=3); (iii) 40μg/kg daily (n=3); (iv) 140μg/kg weekly (n=3); (v) 280μg/kg weekly (n=4). Proximal femurs were imaged ex vivo using micro-CT (Scanco Viva CT-40) at 15μmvoxel size. Areas, pore size, and porosity were analyzed on the total, compact cortex (CC), and transitional zones in a 10mm length region of interest (ROI) starting at the midshaft using StrAx1.0. Compared to controls, the 20μg/kg daily was associated with 3.0% higher porosity in the transitional zone (p=0.09) while the 40μg/kg daily was associated with a higher porosity in the cortex (8.7%; p=0.04) and in the transitional zone (5.7%; p=0.007). The daily regimens were also associated with a greater proportion of porosity due to pores >15μm 2 ; particularly in the transitional zone where 20 and 40μg/kg daily increased porosity 2 fold (p=0.06) and 5 fold (p=0.04) relative controls respectively. The 140 and 280μg/kg weekly were not associated with an increase in porosity. There was no difference in total, compact or transitional zone cross sectional areas between the groups. Effects of intermittent teriparatide depend on the dose and frequency of administration. Daily dosing, particularly the higher dose, but not weekly dosing, increased cortical porosity. Work is needed to investigate the effects of the regimens on

  10. The consequences of a reduction in the administratively applied maximum annual dose equivalent level for an individual in a group of occupationally exposed workers

    International Nuclear Information System (INIS)

    Harrison, N.T.

    1980-02-01

    An analysis is described for predicting the consequences of a reduction in the administratively applied maximum dose equivalent level to individuals in a group of workers occupationally exposed to ionising radiations, for the situation in which no changes are made to the working environment. This limitation of the maximum individual dose equivalent is accommodated by allowing the number of individuals in the working group to increase. The derivation of the analysis is given, together with worked examples, which highlight the important assumptions that have been made and the conclusions that can be drawn. The results are obtained in the form of the capacity of the particular working environment to accommodate the limitation of the maximum individual dose equivalent, the increase in the number of workers required to carry out the productive work and any consequent increase in the occupational collective dose equivalent. (author)

  11. Measurement of cardiopulmonary performance during acute exposure to a 2440-m equivalent atmosphere

    Science.gov (United States)

    Levitan, B. M.; Bungo, M. W.

    1982-01-01

    Each of 20 subjects (ranging in age from 18 to 38 years, 15 being male, five female) was given two Bruce Protocol symptom-limited maximum treadmill stress tests, breathing sea-level compressed air (20.9% O2) for one test and a 2440-m equivalent (15.5% O2) for the other. A significant difference was found to exist between measured VO2 max (p less than 0.0002) and exercise time (p less than 0.0004) for the two conditions. No significant differences were observed in heart rate or the recovery time to a respiratory quotient of less than 1. Hemoglobin saturation, as measured by an ear oximeter, averaged 95% for sea-level and 91% for the 2440-m equivalent gases. These results support a 2440-m equivalent contingency atmosphere in the Space Shuttle prior to donning a low-pressure suit for the purpose reducing nitrogen washout times.

  12. Advancing Research on Racial–Ethnic Health Disparities: Improving Measurement Equivalence in Studies with Diverse Samples

    Science.gov (United States)

    Landrine, Hope; Corral, Irma

    2014-01-01

    To conduct meaningful, epidemiologic research on racial–ethnic health disparities, racial–ethnic samples must be rendered equivalent on other social status and contextual variables via statistical controls of those extraneous factors. The racial–ethnic groups must also be equally familiar with and have similar responses to the methods and measures used to collect health data, must have equal opportunity to participate in the research, and must be equally representative of their respective populations. In the absence of such measurement equivalence, studies of racial–ethnic health disparities are confounded by a plethora of unmeasured, uncontrolled correlates of race–ethnicity. Those correlates render the samples, methods, and measures incomparable across racial–ethnic groups, and diminish the ability to attribute health differences discovered to race–ethnicity vs. to its correlates. This paper reviews the non-equivalent yet normative samples, methodologies and measures used in epidemiologic studies of racial–ethnic health disparities, and provides concrete suggestions for improving sample, method, and scalar measurement equivalence. PMID:25566524

  13. Analytical evaluation of dose measurement of critical accident at SILENE (Contract research)

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Takemi; Tonoike, Kotaro; Miyoshi, Yoshinori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-03-01

    Institute for Radioprotection and Nuclear Safety (IRSN) and the OECD Nuclear Energy Agency (NEA) jointly organized SILENE Accident Dosimetry Intercomparison Exercise to intercompare the dose measurement systems of participating countries. Each participating country carried out dose measurements in the same irradiation field, and the measurement results were mutually compared. The authors participated in the exercise to measure the doses of gamma rays and neutron from SILENE by using thermoluminescence dosimeters (TLD's) and an alanine dosimeter. In this examination, the authors derived evaluation formulae for obtaining a tissue-absorbed dose from measured value (ambient dose equivalent) of TLD for neutron. We reported the tissue-absorbed dose computed using this evaluation formula to OECD/NEA. TLD's for neutron were irradiated in the TRACY facility to verify the evaluation formulae. The results of TLD's were compared with the calculations of MCNP and measurements with alanine dose meter. We found that the ratio of the dose by the evaluation formula to the measured value by the alanine dosimeter was 0.94 and the formula agreed within 6%. From examination of this TRACY, we can conclude that the value reported to OECD/NEA has equivalent accuracy. (author)

  14. Development of a neutron dosemeter for personnel dosimetry with direct response of dose equivalent in neutron fields of different energy spectra. 1

    International Nuclear Information System (INIS)

    Doerschel, B.

    1978-12-01

    An energy-independent neutron dosemeter is described. The dosemeter is based on a dielectric track detector (mica foil of 6 μm thickness) between uranium and a thorium-232 radiator pulverized and pressed with polyvinyl alcohol enclosed within a cadmium shell. The track density is direct proportional to the dose equivalent between 5 x 10 -4 and 10 Sv. When evaluated every two months, the dosemeter has for 3 mSv an error of +- 50% decreasing at higher dose equivalents

  15. Self-Esteem: Assessing Measurement Equivalence in a Multiethnic Sample of Youth

    Science.gov (United States)

    Michaels, Marcia L.; Barr, Alicia; Roosa, Mark W.; Knight, George P.

    2007-01-01

    Global self-worth and five domains of self-esteem (scholastic competence, athletic competence, physical appearance, behavioral conduct, social acceptance) were tested for measurement equivalence in a sample of Anglo American, Mexican American, African American, and Native American youth aged 9 through 14 years. The results revealed that global…

  16. Dispositional resistance to change: Measurement equivalence and the link to personal values across 17 nations

    Czech Academy of Sciences Publication Activity Database

    Oreg, S.; Bayazit, M.; Vakola, M.; Arciniega, L.; Armenakis, A.; Barkauskiene, R.; Bozionelos, N.; Ferič, I.; Fujimoto, Y.; Gonzáles, L.; Han, J.; Hetland, H.; Hřebíčková, Martina; Jimmieson, N.; Kordačová, J.; Kotrla Topič, M.; Mitsuhashi, H.; Mlacić, B.; Ohly, S.; Saksvik, I.; Saksvik, P.O.; van Dam, K.

    2008-01-01

    Roč. 93, č. 4 (2008), s. 935-944 ISSN 0021-9010 R&D Projects: GA AV ČR IAA700250702 Institutional research plan: CEZ:AV0Z70250504 Keywords : resistance to change * personal values * measurement equivalence Subject RIV: AN - Psychology Impact factor: 3.769, year: 2008

  17. Effect of cigarette smoke on the measured equivalent volume activity of 222Rn in air

    International Nuclear Information System (INIS)

    Tuckova, S.; Tykva, R.

    1994-01-01

    The effect of cigarette smoke in air on the increase of the measured equivalent volume activity of 222 Rn is demonstrated. After introduction of the smoke from one cigarette into 1 m 3 of air, this value increased up to ten times as shown be the method of sucking air through a filter. (author) 5 refs.; 1 fig

  18. Nursing home resident quality of life: testing for measurement equivalence across resident, family, and staff perspectives.

    Science.gov (United States)

    Godin, Judith; Keefe, Janice; Kelloway, E Kevin; Hirdes, John P

    2015-10-01

    This study explores the factor structure of the interRAI self-report nursing home quality of life survey and develops a measure that will allow researchers to compare predictors of quality of life (QOL) across resident, family, and staff perspectives. Nursing home residents (N = 319), family members (N = 397), and staff (N = 862) were surveyed about their perceptions of resident QOL. Exploratory factor analyses were conducted on a random half of the staff data. Subsequently, confirmatory factor analysis was used to test for measurement equivalence across the three perspectives. The final model had a four-factor structure (i.e., care and support, food, autonomy, and activities) across all three perspectives. Each factor had at least two items that were equivalent across all three perspectives, which suggests at least partial measurement equivalence. The finding of partial measurement equivalence acknowledges there are important differences between perspectives and provides a tool that researchers can use to compare predictors of QOL, but not levels of agreement across perspectives. Targeting these four aspects is likely to have the additional benefit of improving family and staff perceptions of resident QOL in addition to the resident's own QOL.

  19. Flavor-Oscillation Clocks, Continuous Quantum Measurements and a Violation of Einstein Equivalence Principle

    Science.gov (United States)

    Camacho, A.

    The relation between Einstein equivalence principle and a continuous quantum measurement is analyzed in the context of the recently proposed flavor-oscillation clocks, an idea pioneered by Ahluwalia and Burgard (Gen. Rel. Grav. 29, 681(E) (1997)). We will calculate the measurement outputs if a flavor-oscillation clock, which is immersed in a gravitational field, is subject to a continuous quantum measurement. Afterwards, resorting to the weak equivalence principle, we obtain the corresponding quantities in a freely falling reference frame. Finally, comparing this last result with the measurement outputs that would appear in a Minkowskian space-time it will be found that they do not coincide, in other words, we have a violation of Einstein equivalence principle. This violation appears in two different forms, namely: (i) the oscillation frequency in a freely falling reference frame does not match with the case predicted by general relativity, a feature previously obtained by Ahluwalia; (ii) the probability distribution of the measurement outputs, obtained by an observer in a freely falling reference frame, does not coincide with the results that would appear in the case of a Minkowskian space-time. Concerning this last difference, the probability distribution differs in two directions. Firstly, the maximum, as function of the energy of the system (that emerges if we calculate first the probability distribution in the original curved manifold and then, resorting to the weak equivalence principle, we find the corresponding expression in a freely falling reference frame) is shifted with respect to the case in which the system is in a Minkowskian space-time. Secondly, the magnitude of this maximum is not equal to the respective quantity predicted by general relativity. In other words, we obtain two new theoretical results that predict a violation of Einstein equivalence principle, and that could be measured.

  20. Identification of the plasma magnetic contour from external magnetic measurements by means of equivalent currents

    International Nuclear Information System (INIS)

    Bettini, P.; Bellina, F.; Stella, A.; Trevisan, F.; Formisano, A.; Martone, R.

    2001-01-01

    One of the main research issues in the thermonuclear fusion area is the identification of plasma contour starting from external magnetic measurements. Possible approaches to this inverse problem make use of equivalent currents to represent the plasma internal current density, regularizing in this way the magnetic field reconstruction. Of course, the choice of the representation basis for such equivalent currents is critical. The paper aims at analyzing the effect of the number and position of base currents on the performance of the identification algorithm. (orig.)

  1. Testing for multigroup equivalence of a measuring instrument: a walk through the process.

    Science.gov (United States)

    Byrne, Barbara M

    2008-11-01

    This article presents an overview and application of the steps taken in testing for the equivalence of a measuring instrument across one or more groups. Following a basic description of, and rationale underlying these steps, the process is illustrated with data comprising response scores to four nonacademic subscales (Physical SC [Ability], Physical SC [Appearance], Social SC [Peers], and Social SC [Parents]) of the Self Description Questionnaire-I for Australian (N = 497) and Nigerian (N = 439) adolescents. All tests for validity and equivalence are based on the analysis of covariance structures within the framework of CFA models using the EQS 6 program. Prospective impediments to equivalence are suggested and additional caveats proposed in the special case where the groups under study represent different cultures.

  2. Technology Development for Radiation Dose Measurement and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Hwan; Chang, S. Y.; Lee, T. Y. (and others)

    2007-06-15

    The correction factors essential for the operation of In-Vivo counting system were produced and implemented into a field operation for the improvement of accuracy in measurement of the radioactivity inside a human body. The BiDAS2007 code which calculate an internal dose was developed by upgrading the former code prepared in the previous stage of this project. The method of using the multibioassy data, the maximum likelihood function and the Bayesian statistics were established to an internal dose based on the measurement data of radioactivity, intakes and retention of radioactivity in a human body and it can improve the accuracy in estimation of the intakes of radioactivity and the committed effective dose equivalent. In order to solve the problem of low detection efficiency of the conventional Bonner Sphere (BS) to a high energy neutron, the extended BS's were manufactured and the technique for neutron field spectrometry was established. The fast neutron and gamma spectrometry system with a BC501A scintillation detector was also prepared. Several neutron fluence spectra at several nuclear facilities were measured and collected by using the extended BS. The spectrum weighted responses of some neutron monitoring instruments were also derived by using these spectra and the detector response functions. A high efficient TL material for the neutron personal dosimeter was developed. It solved the main problem of low thermal stability and high residual dose of the commercial TLDs and has the sensitivity to neutron and to gamma radiation with 40 and 10 times higher respectively than them.

  3. An equivalence study comparing nitrous oxide and oxygen with low-dose sevoflurane and oxygen as inhalation sedation agents in dentistry for adults.

    Science.gov (United States)

    Allen, M; Thompson, S

    2014-11-01

    The aim of this study was to examine whether sevoflurane in oxygen was equivalent to near equipotent concentrations of nitrous oxide in oxygen when used as an inhalation sedation agent in terms of patient and user acceptability. Forty anxious dental patients referred to the sedation suite at Cardiff University School of Dentistry received either nitrous oxide to a maximum concentration of 40% or sevoflurane to a maximum concentration of 0.3% for a routine maxillary plastic restoration with articaine infiltration local analgesia. The inhalation sedation agent to be administered was chosen by a random number allocator. Measurements of blood pressure, oxygen saturation, heart rate, respiratory rate and bispectral index were recorded every 5 minutes. At the end of the treatment episode the patient, the operator and an observer who was unaware of the agent used, recorded their impressions about the episode by completing questionnaires. In the doses used in this study, sevoflurane was found to be as effective as an inhalation sedation agent as the standard dose of nitrous oxide used in normal inhalation sedation in the treatment of adult anxious dental patients. Sevoflurane in low concentrations is equivalent in effect to near equipotent concentrations of nitrous oxide. This would suggest that further research, perhaps with slightly higher concentrations of sevoflurane, is needed. If sevoflurane was shown to be acceptable at slightly higher concentrations, there is scope to explore the development of equipment specifically designed to deliver sevoflurane as an inhalation sedation agent in future.

  4. Evaluation of the environmental equivalent dose rate using area monitors for neutrons in clinical linear accelerators

    International Nuclear Information System (INIS)

    Salgado, Ana Paula; Pereira, Walsan Wagner; Patrao, Karla C. de Souza; Fonseca, Evaldo S. da; Batista, Delano V.S.

    2009-01-01

    The Neutron Laboratory of the Radioprotection and Dosimetry Institute - IRD/CNEN, Rio de Janeiro, Brazil, initiated studies on the process of calibration of neutron area monitors and the results of the measurements performed at radiotherapy treatment rooms, containing clinical accelerators

  5. Equivalent dose and activity concentration of radionuclides in soil and plants

    Energy Technology Data Exchange (ETDEWEB)

    Bernasconi, E.; Moyano, A.; Charro, E.; Pena, V.; Gutierrez-Villanueva, J. L.

    2009-07-01

    The main objective is to known radionuclide dispersion (238-U, 226-Ra, 210-Pb, 232-Th, 224-Ra) and bio transfer to tree species. The study area is northeast of Salamanca province (Spain), where the was mining uranium. Initially, were measured of plant. In these samples were determined activity concentrations of radionuclides by gamma spectrometry. (Author)

  6. Effects of ISS equivalent ionizing radiation dose on Human T-lymphocytes

    Science.gov (United States)

    Meloni, Maria Antonia; Pani, Giuseppe; Benotmane, Rafi; Mastroleo, Felice; Aboul-El-Ardat, Khalil; Janssen, Ann; Leysen, Liselotte; Vanhavere, Filip; Leys, Natalie; Galleri, Grazia; Pippia, Proto; Baatout, Sarah

    One of the objectives of the current international space programs is to investigate the effects of cosmic environment on Humans. It is known that during a long exposure to the space conditions, including ionizing radiations and microgravity, the immune system of the astronauts is impaired. In past years several experiments were performed to identify responsible factors of in vitro mitogenic activation process in human T-lymphocytes under simulated microgravity effect and during dedicated space missions. It come out that the lack of immune response in microgravity occurs at the cellular and molecular level. In order to evaluate effects on pure primary T-lymphocytes from peripheral blood exposed to International Space Station (ISS)-like ionizing radiation, we applied a mixture of Cesium-137, as representative of low energy particles, and Californium-252, as representative of hight energy particles, with rate similar to those monitored inside the ISS during previous space mission (Goossens et all. 2006). This facility is available at SCK•CEN (Belgium) (Mastroleo et al., 2009). Although the dose received by the cells was relatively low, flow cytometry analysis 24 hours after irradiation showed a decrease in cell viability coupled with the increase of the caspase-3 activity. However, Bcl-2 activity did not seem to be affected by the radiation. Furthermore, activation of cells induced an increase of the cell size and alteration of cellular morphology. Cell cycle as well as 8-oxo-G were also modified upon radiation and activation. Gene expression analysis shows a modulation of genes rather as a consequence of exposure than with the activation status. 330 genes have been identified to be significantly modulated in function of the time and have been grouped in four different cluster representing significant expression profiles. Preliminary functional analysis shows mainly genes involved in the immune response and inflammatory diseases as well as oxidative stress and

  7. Evaluation of patient skin dose equivalent due to diagnostic procedures with X-rays in Lagos State Nigeria

    International Nuclear Information System (INIS)

    Aweda, M.A.

    2001-01-01

    This paper reports the study of Patient Skin Dose Equivalents in Lagos State, Nigeria, as one of the strategies of patient protection and x-ray procedure quality assessment. 13 most frequent x-ray diagnostic procedures were studied, these were: chest, skull, cervical spine, lumbosacral spine, sinusis, pelvis, plain abdomen, shoulder, foot, hysterosalpingography, intravenous urography, barium meal and barium enema. 1977 procedures were monitored for a period of 12 months in both private and public hospitals carefully selected from all over the state. The results obtained compared favorably well with those from similar studies reported in the literature. The slight differences observed have been ascribed to variations in the patient anatomy, exposure conditions and choice of radiographic parameters. (author)

  8. Neutron equivalent dose rates at the surroundings of the electron linear accelerator operated by the university of Sao Paulo - Physics institute

    International Nuclear Information System (INIS)

    Yanagihara, L.S.

    1984-01-01

    For the determination of the neutron dose rates at the surroundings of an electron linear accelerators it is necessary the knowledge of the neutron spectrum or its mean energy, because the conversion factor of the flux in equivalent dose rates, is strongly dependent on the neutron energy. Taking this fact into consideration, equivalent dose rates were determined in the three representative sites of the IF/USP Linear Electron Accelerator. Also, due to the radiation field be pulsed, a theoretical and experimental study has been realized to evaluate the effect produced by the variation of the field on the detector. (author)

  9. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    Enrique

    the shoulder or thyroid guard, and on the hand.7. Radiologists receive larger radia- tion doses during abdominal studies than during cerebral studies, even though the .... body reading. The sitting position and the radiographer's physical build would also influence the reading. An ineffective thyroid guard, openings on.

  10. Measurement equivalence of the Empowerment Scale for White and Black persons with severe mental illness.

    Science.gov (United States)

    Morris, Scott B; Huang, Jialin; Zhao, Lei; Sergent, Jessica D; Neuhengen, Jonas

    2014-12-01

    The current study examined the measurement equivalence on a measure of personal empowerment for Black and White consumers of mental health services. Confirmatory factor analysis was used to assess measurement equivalence of the 28-item Empowerment Scale (Rogers, Chamberlin, Ellison, & Crean, 1997), using data from 1,035 White and 301 Black persons with severe mental illness. Metric invariance of the Empowerment Scale was supported, in that the factor structure and loadings were equivalent across groups. Scalar invariance was violated on 3 items; however, the impact of these items on scale scores was quite small. Finally, subscales of empowerment tended to be more highly intercorrelated for Black than for White respondents. RESULTS generally support the use of Empowerment Scale for ethnic group comparisons. However, subtle differences in the psychometric properties of this measure suggest that Black and White individuals may conceptualize the construct of empowerment in different ways. Specifically, Black respondents had a lower threshold for endorsing some items on the self-esteem and powerlessness dimensions. Further, White respondents viewed the 3 dimensions of empowerment (self-esteem, powerlessness, and activism) as more distinct, whereas these 3 traits were more strongly interrelated for Blacks. (c) 2014 APA, all rights reserved.

  11. High dose amoxicillin-based first line regimen is equivalent to sequential therapy in the eradication of H. pylori infection.

    Science.gov (United States)

    Franceschi, F; Ojetti, V; Gabrielli, M; Petruzziello, C; Tortora, A; Gasbarrini, G; Lopetuso, L R; Scaldaferri, F; Gasbarrini, A

    2016-01-01

    Helicobater (H.) pylori eradication rates with standard first-line triple therapy have declined to unacceptable levels. To date, amoxicillin-resistant H. pylori strains have rarely been detected. Whether increasing the dosage of amoxicillin in a standard 7 days eradicating regimen may enhance its efficacy is not known. The aim of this paper is to compare the efficacy of a 7 days high-dose amoxicillin based first-line regimen with sequential therapy. We have retrospectively analyzed data from 300 sex and age matched patients, who underwent 3 different therapeutic schemes: (1) standard LCA, lansoprazole 30 mg bid, clarithromycin 500 mg bid and amoxicillin 1000 mg bid for 7 days; (2) high dose LCA (HD-LCA), lansoprazole 30 mg bid, clarithromycin 500 mg bid and amoxicillin 1000 mg tid for 7 days; (3) sequential LACT, lansoprazole 30 mg bid plus amoxicillin 1000 mg bid for 5 days, followed by lansoprazole 30 mg bid, clarithromycin 500 mg bid and tinidazole 500 mg bid for 5 days. Eradication was confirmed by 13C-urea breath test. Compliance and occurrence of adverse effects were also assessed. Eradication rates were: 55% for LCA, 75% for HD-LCA and 73% for LACT. Eradication rates were higher in HD-LCA group compared to LCA (pamoxicillin based eradicating treatment is superior to standard triple therapy and equivalent to sequential therapy; compared to the latter, the shorter duration may represent an advantage.

  12. Radiation dose measurement and alarm equipment

    International Nuclear Information System (INIS)

    Girle, H.D.

    1977-01-01

    This portable radiation personal dosemeter contains only commercially available electronic components and is light, easy to operate, stable and requires practically no maintenance. The radiation which is present produces electrical impulses in a detector in the well known way, whose frequency is propertional to the intensity of radiation. The added number of pulses is therefore a measure of the incoming radiation dose. After passing through a pulse forming circuit the pulses are stored in a digital counter, i.e. they are added. An AND circuit connected to the counter output produces the excitation of the sound generator through a subsequent bistable circuit, if a number of pulses preset in the counter is reached. The sound generator feeds a warning signal to a loudspeaker. A second output after the digital counter converts the added number of pulses to an instrument reading in a digital - analogue converter. This makes it possible to read the instantaneous value of dose while the digital value is not indicated but only used for setting off the alarm. (HP) [de

  13. Measurement equivalence of the Toronto Structured Interview for Alexithymia across language, gender, and clinical status.

    Science.gov (United States)

    Keefer, Kateryna V; Taylor, Graeme J; Parker, James D A; Inslegers, Ruth; Michael Bagby, R

    2015-08-30

    The Toronto Structured Interview for Alexithymia (TSIA) has been translated into Dutch, German, and Italian and validated in clinical and nonclinical populations. In order to make valid comparisons across different population groups, it is important to establish measurement equivalence across variables such as language, gender, and clinical status. Our objective in this study was to establish measurement equivalence in relation to language (English, Dutch, German, and Italian), gender, and clinical status (non-clinical, psychiatric, and medical) using differential item functioning (DIF). The sample was composed of 842 adults representing the four language groups, all of whom had undergone the TSIA assessment as part of several earlier studies. Ordinal Logistic Regression was employed to explore DIF of the TSIA items. Although several items were found to exhibit DIF for language, gender, or clinical status, all of these effects were within an acceptable range. These findings provide support for the measurement equivalence of the TSIA, and allow researchers to reliably compare results from studies using the TSIA across the four language groups, gender, and clinical status. Copyright © 2015. Published by Elsevier Ireland Ltd.

  14. Estimation of neutron dose equivalent at the mezzanine of the Advanced Light Source and the laboratory boundary using the ORNL program MORSE.

    Science.gov (United States)

    Sun, R K

    1990-12-01

    To investigate the radiation effect of neutrons near the Advanced Light Source (ALS) at Lawrence Berkeley Laboratory (LBL) with respect to the neutron dose equivalents in nearby occupied areas and at the site boundary, the neutron transport code MORSE, from Oak Ridge National Laboratory (ORNL), was used. These dose equivalents result from both skyshine neutrons transported by air scattering and direct neutrons penetrating the shielding. The ALS neutron sources are a 50-MeV linear accelerator and its transfer line, a 1.5-GeV booster, a beam extraction line, and a 1.9-GeV storage ring. The most conservative total occupational-dose-equivalent rate in the center of the ALS mezzanine, 39 m from the ALS center, was found to be 1.14 X 10(-3) Sv y-1 per 2000-h "occupational" year, and the total environmental-dose-equivalent rate at the ALS boundary, 125 m from the ALS center, was found to be 3.02 X 10(-4) Sv y-1 per 8760-h calendar year. More realistic dose-equivalent rates, using the nominal (expected) storage-ring current, were calculated to be 1.0 X 10(-4) Sv y-1 and 2.65 X 10(-5) Sv y-1 occupational year and calendar year, respectively, which are much lower than the DOE reporting levels.

  15. Estimation of the contribution of neutrons to the equivalent dose for personnel occupationally exposed and public in medical facilities: X-ray with energy equal or greater than 10MV

    International Nuclear Information System (INIS)

    Gonzalez, Alfonso Mayer; Jimenez, Roberto Ortega; Sanchez, Mario A. Reyes; Moranchel y Mejia, Mario

    2013-01-01

    In Mexico the use of electron accelerators for treating cancerous tumors had grown enormously in the last decade. When the treatments are carried out with X-ray beam energy below 10 MV the design of the shielding of the radioactive facility is determined by analyzing the interaction of X-rays, which have a direct impact and dispersion, with materials of the facility. However, when it makes use of X-ray beam energy equal to or greater than 10 MV the neutrons presence is imminent due to their generation by the interaction of the primary beam X-ray with materials head of the accelerator and of the table of treatment, mainly. In these cases, the design and calculation of shielding considers the generation of high-energy neutrons which contribute the equivalent dose that public and Occupationally Staff Exposed (POE) will receive in the areas surrounding the facility radioactive. However, very few measurements have been performed to determine the actual contribution to the neutron dose equivalent received by POE and public during working hours. This paper presents an estimate of the actual contribution of the neutron dose equivalent received by public and POE facilities in various radioactive medical use, considering many factors. To this end, measurements were made of the equivalent dose by using a neutron monitor in areas surrounding different radioactive installations (of Mexico) which used electron accelerators medical use during treatment with X-ray beam energy equal to or greater than 10 MV. The results are presented after a statistical analysis of a wide range of measures in order to estimate more reliability real contribution of the neutron dose equivalent for POE and the public. (author)

  16. Estimation of the contribution by neutrons to the equivalent dose for exposed occupationally personnel and people in medical use facilities: X rays of equal or superior energy to 10 MV

    International Nuclear Information System (INIS)

    Ortega J, R.; Reyes S, M. A.; Moranchel y R, M.

    2013-10-01

    In Mexico the use of electron accelerators for treating cancerous tumors had grown enormously in the last decade. When the treatments are carried out with X-ray beam energy below 10 MV the design of the shielding of the radioactive facility is determined by analyzing the interaction of X-rays, which have a direct impact and dispersion, with materials of the facility. However, when it makes use of X-ray beam energy equal to or greater than 10 MV the neutrons presence is imminent due to their generation by the interaction of the primary beam X-ray with materials head of the accelerator and of the table of treatment, mainly. In these cases, the design and calculation of shielding considers the generation of high-energy neutrons which contribute the equivalent dose that public and occupationally staff exposed (POE) will receive in the areas surrounding the facility radioactive. However, very few measurements have been performed to determine the actual contribution to the neutron dose equivalent received by POE and public during working hours. This paper presents and estimate of the actual contribution of the neutron dose equivalent received by public and POE facilities in various radioactive medical use, considering many factors. To this end, measurements were made of the equivalent dose by using a neutron monitor in areas surrounding different radioactive installations (of Mexico) which used electron accelerators medical use during treatment with X-ray beam energy equal to or greater than 10 MV. The results are presented after a statistical analysis of a wide range of measures in order to estimate more reliability real contribution of the neutron dose equivalent for POE and the public. (author)

  17. Measurement of radiation dose in multi-slice computed tomography

    OpenAIRE

    Surendra Maharjan; Sudil Prajapati; Om Biju Panta

    2016-01-01

    The aim of this study was to measure the radiation doses for computed tomography (CT) examinations of the head, chest and abdomen in adult patients in Nepal in comparison to international standard. Dose length products (DLP) and effective doses for standard patient sizes were calculated from the reported volume CT dose index (CTDIVol). Details were obtained from approximately 90 CT examinations carried out in 128 slice CT scan. Effective dose was calculated for each examination using CT dose ...

  18. What Do Contrast Threshold Equivalent Noise Studies Actually Measure? Noise vs. Nonlinearity in Different Masking Paradigms.

    Directory of Open Access Journals (Sweden)

    Alex S Baldwin

    Full Text Available The internal noise present in a linear system can be quantified by the equivalent noise method. By measuring the effect that applying external noise to the system's input has on its output one can estimate the variance of this internal noise. By applying this simple "linear amplifier" model to the human visual system, one can entirely explain an observer's detection performance by a combination of the internal noise variance and their efficiency relative to an ideal observer. Studies using this method rely on two crucial factors: firstly that the external noise in their stimuli behaves like the visual system's internal noise in the dimension of interest, and secondly that the assumptions underlying their model are correct (e.g. linearity. Here we explore the effects of these two factors while applying the equivalent noise method to investigate the contrast sensitivity function (CSF. We compare the results at 0.5 and 6 c/deg from the equivalent noise method against those we would expect based on pedestal masking data collected from the same observers. We find that the loss of sensitivity with increasing spatial frequency results from changes in the saturation constant of the gain control nonlinearity, and that this only masquerades as a change in internal noise under the equivalent noise method. Part of the effect we find can be attributed to the optical transfer function of the eye. The remainder can be explained by either changes in effective input gain, divisive suppression, or a combination of the two. Given these effects the efficiency of our observers approaches the ideal level. We show the importance of considering these factors in equivalent noise studies.

  19. A phantom based method for deriving typical patient doses from measurements of dose-area product on populations of patients

    International Nuclear Information System (INIS)

    Chapple, C.-L.; Broadhead, D.A.

    1995-01-01

    One of the chief sources of uncertainty in the comparison of patient dosimetry data is the influence of patient size on dose. Dose has been shown to relate closely to the equivalent diameter of the patient. This concept has been used to derive a prospective, phantom based method for determining size correction factors for measurements of dose-area product. The derivation of the size correction factor has been demonstrated mathematically, and the appropriate factor determined for a number of different X-ray sets. The use of phantom measurements enables the effect of patient size to be isolated from other factors influencing patient dose. The derived factors agree well with those determined retrospectively from patient dose survey data. Size correction factors have been applied to the results of a large scale patient dose survey, and this approach has been compared with the method of selecting patients according to their weight. For large samples of data, mean dose-area product values are independent of the analysis method used. The chief advantage of using size correction factors is that it allows all patient data to be included in a survey, whereas patient selection has been shown to exclude approximately half of all patients. (author)

  20. Occupational dose equivalent limits

    International Nuclear Information System (INIS)

    Goldfinch, E.P.

    1980-01-01

    This paper considers methods of limiting individual radiation risks by recognizing the variation of risk with age at exposure, taking into account both somatic and genetic risks and proposes a simple formula for controlling individual cumulative exposure and hence risk. (Author)

  1. Prediction of midline dose from entrance ad exit dose using OSLD measurements for total irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Park, Jong Min; Park, So Yeon; Chun, Min Soo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-06-15

    This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

  2. Acute non-stochastic effect of very low dose whole-body exposure, a thymidine equivalent serum factor

    International Nuclear Information System (INIS)

    Feinendegen, L.E.; Muehlensiepen, H.; Porschen, W.; Booz, J.

    1982-01-01

    Whole-body irradiation of mice causes the dose-dependent appearance of a humoral factor in blood serum which inhibits incorporation of 125-IUdR into tissue culture cells. This factor appears even at doses below 0.01 Gy gamma irradiation and thus is probably not related to cell death. Data are presented relating this humoral factor to thymidine. Since at low doses the target size for this effect was calculated to be the entire cell, a cellular effect is postulated linking the site of few primary absorption events, anywhere in the cell, with the cellular membrane, thus causing changes in membrane charge, structure and/or fluidity. This may lead to blocking thymidine acceptance by the cell, and thus would cause a pile-up of thymidine in the reutilization pathway in peripheral blood and would give rise to the observed effect. The effect appears as a temporary disturbance of the physiological equilibrium and should not be related at present to any cellular damage. The acute low-dose effect described has implications for the measurement of low-dose exposure by biological dosimeters and on basic research on membrane function. (author)

  3. Measurement of characteristic prompt gamma rays emitted from oxygen and carbon in tissue-equivalent samples during proton beam irradiation.

    Science.gov (United States)

    Polf, Jerimy C; Panthi, Rajesh; Mackin, Dennis S; McCleskey, Matt; Saastamoinen, Antti; Roeder, Brian T; Beddar, Sam

    2013-09-07

    The purpose of this work was to characterize how prompt gamma (PG) emission from tissue changes as a function of carbon and oxygen concentration, and to assess the feasibility of determining elemental concentration in tissues irradiated with proton beams. For this study, four tissue-equivalent water-sucrose samples with differing densities and concentrations of carbon, hydrogen, and oxygen were irradiated with a 48 MeV proton pencil beam. The PG spectrum emitted from each sample was measured using a high-purity germanium detector, and the absolute detection efficiency of the detector, average beam current, and delivered dose distribution were also measured. Changes to the total PG emission from (12)C (4.44 MeV) and (16)O (6.13 MeV) per incident proton and per Gray of absorbed dose were characterized as a function of carbon and oxygen concentration in the sample. The intensity of the 4.44 MeV PG emission per incident proton was found to be nearly constant for all samples regardless of their carbon concentration. However, we found that the 6.13 MeV PG emission increased linearly with the total amount (in grams) of oxygen irradiated in the sample. From the measured PG data, we determined that 1.64 × 10(7) oxygen PGs were emitted per gram of oxygen irradiated per Gray of absorbed dose delivered with a 48 MeV proton beam. These results indicate that the 6.13 MeV PG emission from (16)O is proportional to the concentration of oxygen in tissue irradiated with proton beams, showing that it is possible to determine the concentration of oxygen within tissues irradiated with proton beams by measuring (16)O PG emission.

  4. Measurement of characteristic prompt gamma rays emitted from oxygen and carbon in tissue-equivalent samples during proton beam irradiation

    International Nuclear Information System (INIS)

    Polf, Jerimy C; Panthi, Rajesh; Mackin, Dennis S; Beddar, Sam; McCleskey, Matt; Saastamoinen, Antti; Roeder, Brian T

    2013-01-01

    The purpose of this work was to characterize how prompt gamma (PG) emission from tissue changes as a function of carbon and oxygen concentration, and to assess the feasibility of determining elemental concentration in tissues irradiated with proton beams. For this study, four tissue-equivalent water–sucrose samples with differing densities and concentrations of carbon, hydrogen, and oxygen were irradiated with a 48 MeV proton pencil beam. The PG spectrum emitted from each sample was measured using a high-purity germanium detector, and the absolute detection efficiency of the detector, average beam current, and delivered dose distribution were also measured. Changes to the total PG emission from 12 C (4.44 MeV) and 16 O (6.13 MeV) per incident proton and per Gray of absorbed dose were characterized as a function of carbon and oxygen concentration in the sample. The intensity of the 4.44 MeV PG emission per incident proton was found to be nearly constant for all samples regardless of their carbon concentration. However, we found that the 6.13 MeV PG emission increased linearly with the total amount (in grams) of oxygen irradiated in the sample. From the measured PG data, we determined that 1.64 × 10 7 oxygen PGs were emitted per gram of oxygen irradiated per Gray of absorbed dose delivered with a 48 MeV proton beam. These results indicate that the 6.13 MeV PG emission from 16 O is proportional to the concentration of oxygen in tissue irradiated with proton beams, showing that it is possible to determine the concentration of oxygen within tissues irradiated with proton beams by measuring 16 O PG emission. (paper)

  5. Testing for Measurement and Structural Equivalence in Large-Scale Cross-Cultural Studies: Addressing the Issue of Nonequivalence

    Science.gov (United States)

    Byrne, Barbara M.; van de Vijver, Fons J. R.

    2010-01-01

    A critical assumption in cross-cultural comparative research is that the instrument measures the same construct(s) in exactly the same way across all groups (i.e., the instrument is measurement and structurally equivalent). Structural equation modeling (SEM) procedures are commonly used in testing these assumptions of multigroup equivalence.…

  6. Using generalized equivalent uniform dose atlases to combine and analyze prospective dosimetric and radiation pneumonitis data from 2 non-small cell lung cancer dose escalation protocols.

    Science.gov (United States)

    Liu, Fan; Yorke, Ellen D; Belderbos, José S A; Borst, Gerben R; Rosenzweig, Kenneth E; Lebesque, Joos V; Jackson, Andrew

    2013-01-01

    To demonstrate the use of generalized equivalent uniform dose (gEUD) atlas for data pooling in radiation pneumonitis (RP) modeling, to determine the dependence of RP on gEUD, to study the consistency between data sets, and to verify the increased statistical power of the combination. Patients enrolled in prospective phase I/II dose escalation studies of radiation therapy of non-small cell lung cancer at Memorial Sloan-Kettering Cancer Center (MSKCC) (78 pts) and the Netherlands Cancer Institute (NKI) (86 pts) were included; 10 (13%) and 14 (17%) experienced RP requiring steroids (RPS) within 6 months after treatment. gEUD was calculated from dose-volume histograms. Atlases for each data set were created using 1-Gy steps from exact gEUDs and RPS data. The Lyman-Kutcher-Burman model was fit to the atlas and exact gEUD data. Heterogeneity and inconsistency statistics for the fitted parameters were computed. gEUD maps of the probability of RPS rate≥20% were plotted. The 2 data sets were homogeneous and consistent. The best fit values of the volume effect parameter a were small, with upper 95% confidence limit around 1.0 in the joint data. The likelihood profiles around the best fit a values were flat in all cases, making determination of the best fit a weak. All confidence intervals (CIs) were narrower in the joint than in the individual data sets. The minimum P value for correlations of gEUD with RPS in the joint data was .002, compared with P=.01 and .05 for MSKCC and NKI data sets, respectively. gEUD maps showed that at small a, RPS risk increases with gEUD. The atlas can be used to combine gEUD and RPS information from different institutions and model gEUD dependence of RPS. RPS has a large volume effect with the mean dose model barely included in the 95% CI. Data pooling increased statistical power. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Using Generalized Equivalent Uniform Dose Atlases to Combine and Analyze Prospective Dosimetric and Radiation Pneumonitis Data From 2 Non-Small Cell Lung Cancer Dose Escalation Protocols

    Energy Technology Data Exchange (ETDEWEB)

    Liu Fan; Yorke, Ellen D. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Belderbos, Jose S.A.; Borst, Gerben R. [The Netherlands Cancer Institute, Antoni Van Leeuwenhoek Hospital, Amsterdam (Netherlands); Rosenzweig, Kenneth E. [Mount Sinai School of Medicine, New York, New York (United States); Lebesque, Joos V. [The Netherlands Cancer Institute, Antoni Van Leeuwenhoek Hospital, Amsterdam (Netherlands); Jackson, Andrew, E-mail: jacksona@mskcc.org [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2013-01-01

    Purpose: To demonstrate the use of generalized equivalent uniform dose (gEUD) atlas for data pooling in radiation pneumonitis (RP) modeling, to determine the dependence of RP on gEUD, to study the consistency between data sets, and to verify the increased statistical power of the combination. Methods and Materials: Patients enrolled in prospective phase I/II dose escalation studies of radiation therapy of non-small cell lung cancer at Memorial Sloan-Kettering Cancer Center (MSKCC) (78 pts) and the Netherlands Cancer Institute (NKI) (86 pts) were included; 10 (13%) and 14 (17%) experienced RP requiring steroids (RPS) within 6 months after treatment. gEUD was calculated from dose-volume histograms. Atlases for each data set were created using 1-Gy steps from exact gEUDs and RPS data. The Lyman-Kutcher-Burman model was fit to the atlas and exact gEUD data. Heterogeneity and inconsistency statistics for the fitted parameters were computed. gEUD maps of the probability of RPS rate {>=}20% were plotted. Results: The 2 data sets were homogeneous and consistent. The best fit values of the volume effect parameter a were small, with upper 95% confidence limit around 1.0 in the joint data. The likelihood profiles around the best fit a values were flat in all cases, making determination of the best fit a weak. All confidence intervals (CIs) were narrower in the joint than in the individual data sets. The minimum P value for correlations of gEUD with RPS in the joint data was .002, compared with P=.01 and .05 for MSKCC and NKI data sets, respectively. gEUD maps showed that at small a, RPS risk increases with gEUD. Conclusions: The atlas can be used to combine gEUD and RPS information from different institutions and model gEUD dependence of RPS. RPS has a large volume effect with the mean dose model barely included in the 95% CI. Data pooling increased statistical power.

  8. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists.

    Science.gov (United States)

    Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M

    2016-01-01

    To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = radiography (P radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run.

  9. Verification of Entrance Dose Measurements with ...

    African Journals Online (AJOL)

    TLD system at the Radiation Monitoring and. Protection Centre, Lagos State University, Ojo, Lagos‑Nigeria was used for the in vivo entrance dose readings. All patients were treated with Co‑60 (T780c) ... and to determine the influence of shape, size, and density variations of the body of the patient on the dose calculation.

  10. Incidence of late rectal bleeding in high-dose conformal radiotherapy of prostate cancer using equivalent uniform dose-based and dose-volume-based normal tissue complication probability models

    International Nuclear Information System (INIS)

    Soehn, Matthias; Yan Di; Liang Jian; Meldolesi, Elisa; Vargas, Carlos; Alber, Markus

    2007-01-01

    Purpose: Accurate modeling of rectal complications based on dose-volume histogram (DVH) data are necessary to allow safe dose escalation in radiotherapy of prostate cancer. We applied different equivalent uniform dose (EUD)-based and dose-volume-based normal tissue complication probability (NTCP) models to rectal wall DVHs and follow-up data for 319 prostate cancer patients to identify the dosimetric factors most predictive for Grade ≥ 2 rectal bleeding. Methods and Materials: Data for 319 patients treated at the William Beaumont Hospital with three-dimensional conformal radiotherapy (3D-CRT) under an adaptive radiotherapy protocol were used for this study. The following models were considered: (1) Lyman model and (2) logit-formula with DVH reduced to generalized EUD (3) serial reconstruction unit (RU) model (4) Poisson-EUD model, and (5) mean dose- and (6) cutoff dose-logistic regression model. The parameters and their confidence intervals were determined using maximum likelihood estimation. Results: Of the patients, 51 (16.0%) showed Grade 2 or higher bleeding. As assessed qualitatively and quantitatively, the Lyman- and Logit-EUD, serial RU, and Poisson-EUD model fitted the data very well. Rectal wall mean dose did not correlate to Grade 2 or higher bleeding. For the cutoff dose model, the volume receiving > 73.7 Gy showed most significant correlation to bleeding. However, this model fitted the data more poorly than the EUD-based models. Conclusions: Our study clearly confirms a volume effect for late rectal bleeding. This can be described very well by the EUD-like models, of which the serial RU- and Poisson-EUD model can describe the data with only two parameters. Dose-volume-based cutoff-dose models performed worse

  11. Measurement of vocal doses in virtual classrooms

    DEFF Research Database (Denmark)

    Bottalico, Pasquale; Pelegrin Garcia, David

    2010-01-01

    different acoustical conditions, that combined different kind of background noise and virtual classroom acoustics. Readings from the vocal fold vibrations were registered with an Ambulatory Phonation Monitor device. The speech signal from the talker in the center of the facility was picked up with a head...... with an artificial head (corresponding to the mouth-ears path) placed at the talker position while simulating the classrooms. Time histories of the vocal fold vibration readings, with the trend of the fundamental frequency and an estimation of the sound pressure level, sampled every 50 ms, were obtained. From...... these data the vocal doses Time dose, Vocal Loading Index, Distance Dose, Energy Dissipation Dose, and Radiated Energy Dose were calculated and correlated with the acoustical features of the classrooms....

  12. An overview of measuring and modelling dose and risk from ionising radiation for medical exposures

    International Nuclear Information System (INIS)

    Tootell, Andrew; Szczepura, Katy; Hogg, Peter

    2014-01-01

    Purpose: This paper gives an overview of the methods that are used to calculate dose and risk from exposure to ionizing radiation as a support to other papers in this special issue. Background: The optimization of radiation dose is a legal requirement in medical exposures. This review paper aims to provide the reader with knowledge of dose by providing definitions and concepts of absorbed, effective and equivalent dose. Criticisms of the use of effective dose to infer the risk of an exposure to an individual will be discussed and an alternative approach considering the lifetime risks of cancer incidence will be considered. Prior to any dose or risk calculation, data concerning the dose absorbed by the patient needs to be collected. This paper will describe and discuss the main concepts and methods that can be utilised by a researcher in dose assessments. Concepts behind figures generated by imaging equipment such as dose-area-product, computed tomography dose index, dose length product and their use in effective dose calculations will be discussed. Processes, advantages and disadvantages in the simulation of exposures using the Monte Carlo method and direct measurement using digital dosimeters or thermoluminescent dosimeters will be considered. Beyond this special issue, it is proposed that this paper could serve as a teaching or CPD tool for personnel working or studying medical imaging

  13. A volume-equivalent spherical necrosis-tumor-normal liver model for estimating absorbed dose in yttrium-90 microsphere therapy.

    Science.gov (United States)

    Wu, Chin-Hui; Liao, Yi-Jen; Lin, Tzung-Yi; Chen, Yu-Cheng; Sun, Shung-Shung; Liu, Yen-Wan Hsueh; Hsu, Shih-Ming

    2016-11-01

    Primary hepatocellular carcinoma and metastatic liver tumors are highly malignant tumors in Asia. The incidence of fatal liver cancer is also increasing in the United States. The aim of this study was to establish a spherical tumor model and determine its accuracy in predicting the absorbed dose in yttrium-90 (Y-90) microsphere therapy for liver cancer. Liver morphology can be approximated by a spherical model comprising three concentric regions representing necrotic, tumor, and normal liver tissues. The volumes of these three regions represent those in the actual liver. A spherical tumor model was proposed to calculate the absorbed fractions in the spherical tumor, necrotic, and normal tissue regions. The THORplan treatment planning system and Monte Carlo N-particle extended codes were used for this spherical tumor model. Using the volume-equivalent method, a spherical tumor model was created to calculate the total absorbed fraction [under different tumor-to-healthy-liver ratios (TLRs)]. The patient-specific model (THORplan) results were used to verify the spherical tumor model results. The results for both the Y-90 spectrum and the Y-90 mean energy indicated that the absorbed fraction was a function of the tumor radius and mass. The absorbed fraction increased with tumor radius. The total absorbed fractions calculated using the spherical tumor model for necrotic, liver tumor, and normal liver tissues were in good agreement with the THORplan results, with differences of less than 3% for TLRs of 2-5. The results for the effect of TLR indicate that for the same tumor configuration, the total absorbed fraction decreased with increasing TLR; for the same shell tumor thickness and TLR, the total absorbed fraction was approximately constant; and for tumors with the same radius, the total fraction absorbed by the tumor increased with the shell thickness. The results from spherical tumor models with different tumor-to-healthy-liver ratios were highly consistent with the

  14. The current status of eye lens dose measurement in interventional cardiology personnel in Thailand.

    Science.gov (United States)

    Krisanachinda, Anchali; Srimahachota, Suphot; Matsubara, Kosuke

    2017-06-01

    Workers involved in interventional cardiology procedures receive high eye lens doses if radiation protection tools are not properly utilized. Currently, there is no suitable method for routine measurement of eye dose. In Thailand, the eye lens equivalent doses in terms of Hp(3) of the interventional cardiologists, nurses, and radiographers participating in interventional cardiology procedures have been measured at 12 centers since 2015 in the pilot study. The optically stimulated luminescence (OSL) dosimeter was used for measurement of the occupational exposure and the eye lens dose of 42 interventional cardiology personnel at King Chulalongkorn Memorial Hospital as one of the pilot centers. For all personnel, it is recommended that a first In Light OSL badge is placed at waist level and under the lead apron for determination of Hp(10); a second badge is placed at the collar for determination of Hp(0.07) and estimation of Hp(3). Nano Dots OSL dosimeter has been used as an eye lens dosimeter for 16 interventional cardiology personnel, both with and without lead-glass eyewear. The mean effective dose at the body, equivalent dose at the collar, and estimated eye lens dose were 0.801, 5.88, and 5.70 mSv per year, respectively. The mean eye lens dose measured by the Nano Dots dosimeter was 8.059 mSv per year on the left eye and 3.552 mSv per year on the right eye. Two of 16 interventional cardiologists received annual eye lens doses on the left side without lead glass that were higher than 20 mSv per year, the new eye lens dose limit as recommended by ICRP with the risk of eye lens opacity and cataract.

  15. Measurements of soot formation and hydroxyl concentration in near critical equivalence ratio premixed ethylene flame

    Science.gov (United States)

    Inbody, Michael Andrew

    1993-01-01

    The testing and development of existing global and detailed chemical kinetic models for soot formation requires measurements of soot and radical concentrations in flames. A clearer understanding of soot particle inception relies upon the evaluation and refinement of these models in comparison with such measurements. We present measurements of soot formation and hydroxyl (OH) concentration in sequences of flat premixed atmospheric-pressure C2H4/O2/N2 flames and 80-torr C2H4/O2 flames for a unique range of equivalence ratios bracketting the critical equivalence ratio (phi(sub c)) and extending to more heavily sooting conditions. Soot volume fraction and number density profiles are measured using a laser scattering-extinction apparatus capable of resolving a 0.1 percent absorption. Hydroxyl number density profiles are measured using laser-induced fluorescence (LIF) with broadband detection. Temperature profiles are obtained from Rayleigh scattering measurements. The relative volume fraction and number density profiles of the richer sooting flames exhibit the expected trends in soot formation. In near-phi(sub c) visibility sooting flames, particle scattering and extinction are not detected, but an LIF signal due to polycyclic aromatic hydrocarbons (PAH's) can be detected upon excitation with an argon-ion laser. A linear correlation between the argon-ion LIF and the soot volume fraction implies a common mechanistic source for the growth of PAH's and soot particles. The peak OH number density in both the atmospheric and 80-torr flames declines with increasing equivalence ratio, but the profile shape remains unchanged in the transition to sooting, implying that the primary reaction pathways for OH remain unchanged over this transition. Chemical kinetic modeling is demonstrated by comparing predictions using two current reaction mechanisms with the atmospheric flame data. The measured and predicted OH number density profiles show good agreement. The predicted benzene

  16. Evaluating measurement equivalence across race and ethnicity on the CAHPS Cultural Competence Survey.

    Science.gov (United States)

    Carle, Adam C; Weech-Maldonado, Robert; Ngo-Metzger, Quyen; Hays, Ron D

    2012-09-01

    The Consumer Assessments of Healthcare Providers and Systems (CAHPS) Cultural Competence Survey assesses patients' experiences with culturally competent care. This study evaluates the equivalence of responses to this survey across different racial and ethnic subgroups. In this study, we examined whether measurement bias on the CAHPS Cultural Competence Survey impedes valid measurement across white, black, and Hispanic patients. We used multiple group (MG) confirmatory factor analyses (CFA) to examine possible measurement bias across non-Hispanic white (n=146), non-Hispanic black (n=148), and Hispanic (n=339) adults. Participants came from 2 Medicaid managed care plans, one in New York and the other in California in 2008. MG-CFA provided general support for the equivalence of the CAHPS Cultural Competence Survey in measuring doctor communication, health promotion, and perceived trust across groups. However, we observed statistically significant differences in the thresholds associated with the Doctor Communication--Positive Behaviors. Nevertheless, sensitivity analyses indicated that measurement bias did not meaningfully influence conclusions about average experiences with culturally competent care across non-Hispanic white, non-Hispanic black, and Hispanic patients in our sample. Our results support the use of the CAHPS Cultural Competence Survey across non-Hispanic white, non-Hispanic black, and Hispanic patients. Though we found some statistically significant measurement bias, sensitivity analyses demonstrated that measurement bias does not substantively influence conclusions based on patients' responses. Health providers at various levels can place confidence in the CAHPS Cultural Competence Survey and use it in diverse populations to evaluate patients' experiences with culturally competent care.

  17. Estimation of annual dose equivalent (internal and external) for new thorium plant workers of IRE OSCOM, Orissa

    International Nuclear Information System (INIS)

    Vidya Sagar, D.; Tripathy, S.K.; Khan, A.H.; Maharana, L.N.

    2001-01-01

    In addition to thoron, thoron daughters and gamma radiation, the New Thorium Plant workers are exposed to long lived alpha emitters due to inhalation of thorium fine dust present in the working environment. Air samplers were used for measurement of thoron daughters and long lived alpha concentration. Each sample was counted for 3-4 hours for alpha activity and the long lived alpha concentration was calculated after taking the self absorption effect of the deposit on the filter paper into account. Internal dose of individual workers due to thoron daughter concentration and long lived alpha concentration was determined using time weighted factors. Based on the results, it is observed that contribution of thoron daughters, long lived alpha and external gamma is about 2 mSv /y, 1 mSv /y and 5 mSv/y, respectively, to total dose to the workers. (author)

  18. A conversion method of air-kerma from the primary, scatter and leakage radiations to ambient dose equivalent for calculating the mamography x-ray shielding barrier

    International Nuclear Information System (INIS)

    Kharrati, H.

    2005-01-01

    The primary, scatter, and leakage doses(in Gy), which constitute the data base for calculating shielding requirements for x-ray facilities, are often converted to the equivalent dose (in sievert) by using a constant of conversion of 1.145Sv/Gy. This constant is used for diagnostic radiology as well as for mammography spectra, and is derived by considering an exposure of 1 R corresponds to an air kerma of 8.73 m Gy, which renders by tradition an equivalent dose of 10 mSv. However, this conversion does not take into account the energy dependence of the conversion coefficients relating air kerma to the equivalent dose as described in ICRU report. Moreover, current radiation protection standards propose the use of the quantity ambient dose equivalent in order to qualify the efficiently of given radiation shielding. Therefore, in this study, a new approach has been introduced for derivation ambient dose equivalent from air kerma to calculate shielding requirements in mammography facilities. This new approach has been used to compute the conversion coefficients relating air kerma to ambient dose equivalent for mammography reference beam series of the Netherlands Metrology Institute Van Swinden Laboratorium (NMi), National Institute of Standards and Technology (NIST), and International Atomic Energy Agency (AIEA) laboratories. The calculation has been performed by the means of two methods which show a maximum deviation less than 10%2 for the primary, scatter, and leakage radiations. The results show that the conversion coefficients vary from 0.242 Sv/ Gy to 0.692 Sv/Gy with an average value of 0.436 Sv/Gy for the primary and the scatter radiations, and form 0.156 Sv/Gy to 1.329 Sv/Gy with an average value of 0.98 Sv/Gy for the leakage radiation. Simpkin et al. using an empirical approach propose a conversion value of 0.50 Sv/Gy for the mammography x-ray spectra. This value approximately coincides with the average conversion value of 0.436 Sv/Gy obtained in this work for

  19. Laser-based irradiation apparatus and method to measure the functional dose-rate response of semiconductor devices

    Science.gov (United States)

    Horn, Kevin M [Albuquerque, NM

    2008-05-20

    A broad-beam laser irradiation apparatus can measure the parametric or functional response of a semiconductor device to exposure to dose-rate equivalent infrared laser light. Comparisons of dose-rate response from before, during, and after accelerated aging of a device, or from periodic sampling of devices from fielded operational systems can determine if aging has affected the device's overall functionality. The dependence of these changes on equivalent dose-rate pulse intensity and/or duration can be measured with the apparatus. The synchronized introduction of external electrical transients into the device under test can be used to simulate the electrical effects of the surrounding circuitry's response to a radiation exposure while exposing the device to dose-rate equivalent infrared laser light.

  20. Conjugacy, orbit equivalence and classification of measure-preserving group actions

    DEFF Research Database (Denmark)

    Törnquist, Asger Dag

    2009-01-01

    . Further, we obtain that the measure-preserving almost-everywhere-free ergodic actions of such a G cannot be classified up to orbit equivalence by a reasonable assignment of countable structures as complete invariants. We also obtain a strengthening and a new proof of a non-classification result of Foreman......We prove that if G is a countable discrete group with property (T) over an infinite subgroup HG which contains an infinite Abelian subgroup or is normal, then G has continuum-many orbit-inequivalent measure-preserving almost-everywhere-free ergodic actions on a standard Borel probability space...... and Weiss for conjugacy of measure-preserving ergodic almost-everywhere-free actions of discrete countable groups....

  1. Rotor equivalent wind speed for power curve measurement – comparative exercise for IEA Wind Annex 32

    DEFF Research Database (Denmark)

    Wagner, Rozenn; Cañadillas, B.; Clifton, A.

    2014-01-01

    A comparative exercise has been organised within the International Energy Agency (IEA) Wind Annex 32 in order to test the Rotor Equivalent Wind Speed (REWS) method under various conditions of wind shear and measurement techniques. Eight organisations from five countries participated in the exercise....... Each member of the group has derived both the power curve based on the wind speed at hub height and the power curve based on the REWS. This yielded results for different wind turbines, located in diverse types of terrain and where the wind speed profile was measured with different instruments (mast...... was the definition of the segment area used as weighting for the wind speeds measured at the various heights in the calculation of the REWS. This comparative exercise showed that the REWS method results in a significant difference compared to the standard method using the wind speed at hub height in conditions...

  2. Technical Note: Out-of-field dose measurement at near surface with plastic scintillator detector.

    Science.gov (United States)

    Bourgouin, Alexandra; Varfalvy, Nicolas; Archambault, Louis

    2016-09-08

    Out-of-field dose depends on multiple factors, making peripheral dosimetry com-plex. Only a few dosimeters have the required features for measuring peripheral dose. Plastic scintillator dosimeters (PSDs) offer numerous dosimetric advantages as required for out-of-field dosimetry. The purpose of this study is to determine the potential of using PSD as a surface peripheral dosimeter. Measurements were performed with a parallel-plate ion chamber, a small volume ion chamber, and with a PSD. Lateral-dose measurements (LDM) at 0.5 cm depth and depth-dose curve (PDD) were made and compared to the dose calculation provided by a treatment planning system (TPS). This study shows that a PSD can measure a dose as low as 0.51 ± 0.17 cGy for photon beam and 0.58 ± 0.20 cGy for electron beam with a difference of 0.2 and 0.1 cGy compared to a parallel-plate ion chamber. This study demonstrates the potential of using PSD as an out-of-field dosimeter since measure-ments with PSD avoid averaging over a too-large depth, at 1 mm diameter, and can make precise measurement at very low dose. Also, electronic equilibrium is easier to reach with PSD due to its small sensitive volume and its water equivalence. © 2016 The Authors.

  3. Photon and neutron doses of the personnel using moisture and density measurement devices

    International Nuclear Information System (INIS)

    Carinou, E.; Papadomarkaki, E.; Tritakis, P.; Hourdakis, C.I.; Kamenopoulou, V.

    2006-01-01

    The objective of this study is to present the evolution of the photon doses received by the workers who use mobile devices for measuring the moisture and the density in various materials and to estimate the neutron doses. The workers employed in more than 30 construction companies in Greece were 76 in 2004. The devices used for that purpose incorporate a 137 Cs source for density measurements and an 241 Am-Be source for moisture measurements of soil, asphalt or concrete. Photon and neutron measurements were performed occasionally during the on site inspections. The results of the measurements showed that the photon and neutron dose rates were not negligible. The workers were monitored for photon radiation using film badges (Kodak Type 2, Holder NRPB type) till the year 2000 and then TLD badges issued by the Greek Atomic Energy Commission (GAEC), on a monthly basis. Since the neutron dose rates measured by a rem-meter were not so high, no neutron dosemeters were issued for them. Their personal dose equivalent data for photons are kept in the National Dose Registry Information System (N.D.R.I.S.) in G.A.E.C. and were used for statistical analysis for the period from 1997 till 2004. As far as the neutrons are concerned, a Monte Carlo code was used to simulate the measuring devices and the working positions in order to calculate the neutron individual doses. (authors)

  4. Study of the radiation scattered and produced by concrete shielding of radiotherapy rooms and its effects on equivalent doses in patients' organs

    International Nuclear Information System (INIS)

    Braga, K.L.; Rebello, W.F.; Andrade, E.R.; Gavazza, S.; Medeiros, M.P.C.; Mendes, R.M.S.; Gomes, R.G.; Silva, M.G.; Thalhofer, J.L.; Silva, A.X.; Santos, R.F.G.

    2015-01-01

    Within a radiotherapy room, in addition to the primary beam, there is also secondary radiation due to the leakage of the accelerator head and the radiation scattering from room objects, patient and even the room's shielding itself, which is projected to protect external individuals disregarding its effects on the patient. This work aims to study the effect of concrete shielding wall over the patient, taking into account its contribution on equivalent doses. The MCNPX code was used to model the linear accelerator Varian 2100/2300 C/D operating at 18MeV, with MAX phantom representing the patient undergoing radiotherapy treatment for prostate cancer following Brazilian Institute of Cancer four-fields radiation application protocol (0°, 90°, 180° and 270°). Firstly, the treatment was patterned within a standard radiotherapy room, calculating the equivalent doses on patient's organs individually. In a second step, this treatment was modeled withdrawing the walls, floor and ceiling from the radiotherapy room, and then the equivalent doses calculated again. Comparing these results, it was found that the concrete has an average shielding contribution of around 20% in the equivalent dose on the patient's organs. (author)

  5. Re-establishment of the air kerma and ambient dose equivalent standards for the BIPM protection-level 60Co beam

    International Nuclear Information System (INIS)

    Kessler, C.; Roger, P.

    2005-07-01

    The air kerma and ambient dose equivalent standards for the protection-level 60 Co beam have been re-established following the repositioning of the irradiator and modifications to the beam. Details concerning the standards and the new uncertainty budgets are described in this report with their implications for dosimetry comparisons and calibrations. (authors)

  6. Calibration procedures of area monitors in terms of the Ambient Dose Equivalent H*(10), for gamma, x-ray radiation fields

    International Nuclear Information System (INIS)

    Dieguez Davila, L.E.

    1998-01-01

    In the present thesis procedures for calibrating portable survey meters in terms of the new ICRU quantities H*(10) ambient dose equivalent are discussed. Also the remendations of International Comission on Radiation Protection in their report ICRP 60 that inludes the operational magnitudes that the International Comission of Radiation Units proposed for calibrating area monitors

  7. Measurement of temperature, fuel concentration and equivalence ratio fields using tracer LIF in IC engine combustion

    Science.gov (United States)

    Einecke, S.; Schulz, C.; Sick, V.

    2000-11-01

    A technique based on planar laser-induced fluorescence of 3-pentanone, for measurements of absolute concentration, temperature and fuel/air equivalence ratios in turbulent, high-pressure combustion systems such as an internal combustion engine is presented. Quasi-simultaneous excitation with 248 nm and 308 nm of 3-pentanone that is used as a fluorescence tracer doped to iso-octane, yields pairs of strongly temperature-dependent fluorescence images. Previous investigations have resulted in information on temperature and pressure dependence of absorption cross-sections and fluorescence quantum yields. Using these data the ratio of corresponding fluorescence images can be converted to temperature images. Instantaneous temperature distribution fields in the compression stroke and in the unburned end-gas of an SI engine were measured. The temperature fields obtained from the two-line technique are used to correct the original tracer-LIF images in order to evaluate quantitative fuel distributions in terms of number densities and fuel/air equivalence ratio.

  8. Electron fluence to dose equivalent conversion factors calculated with EGS3 for electrons and positrons with energies from 100 keV to 20 GeV

    International Nuclear Information System (INIS)

    Rogers, D.W.O.

    1983-01-01

    At NRC the general purpose Monte-Carlo electron-photon transport code EGS3 is being applied to a variety of radiation dosimetry problems. To test its accuracy at low energies a detailed set of depth-dose curves for electrons and photons has been generated and compared to previous calculations. It was found that by changing the default step-size algorithm in EGS3, significant changes were obtained for incident electron beam cases. It was found that restricting the step-size to a 4% energy loss was appropriate below incident electron beam energies of 10 MeV. With this change, the calculated depth-dose curves were found to be in reasonable agreement with other calculations right down to incident electron energies of 100 keV although small (less than or equal to 10%) but persistent discrepancies with the NBS code ETRAN were obtained. EGS3 predicts higher initial dose and shorter range than ETRAN. These discrepancies are typical of a wide range of energies as is the better agreement with the results of Nahum. Data is presented for the electron fluence to maximal dose equivalent in a 30 cm thick slab of ICRU 4-element tissue irradiated by broad parallel beams of electrons incident normal to the surface. On their own, these values only give an indication of the dose equivalent expected from a spectrum of electrons since one needs to fold the spectrum maximal dose equivalent value. Calculations have also been done for incident positron beams. Despite the large statistical uncertainties, maximal dose equivalent although their values are 5 to 10% lower in a band around 10 MeV

  9. On the applicability of the leading edge method to obtain equivalent doses in OSL dating and dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Woda, C. [Helmholtz Zentrum Muenchen - German Research Center for Environmental Health, Institute of Radiation Protection, D-85764 Neuherberg (Germany)], E-mail: clemens.woda@helmholtz-muenchen.de; Fuchs, M. [Lehrstuhl Geomorphologie, Universitaet Bayreuth, D-95440 Bayreuth (Germany)

    2008-01-15

    The applicability of an objective methodology for dose distribution analysis proposed by Lepper and McKeever [2002. An objective methodology for dose distribution analysis. Radiat. Prot. Dosimetry 101 (1-4), 349-352] to samples, where available material only allows the measurement of a small number of aliquots, is investigated. The basis for the study are artificially and naturally insufficiently bleached samples for which a large number (>90) of aliquots were measured. Smaller sets of aliquots are then randomly drawn from this pool and a Gaussian function fitted to the rising limb of the dose distribution. It is found that when the method is based on a three-parameter fit, it is no longer applicable when the number of aliquots is significantly reduced. The percentage of successful fits for data sets made of only 20 aliquots was on average below 20%. In addition for data sets composed of 40 to 60 aliquots, palaeodoses obtained from fitting spread over a large dose range and showed a strongly asymmetric distribution. A significant improvement could be achieved by fixing the center of the Gaussian function to the mode D{sub E} bin and only fitting a two-parameter function to the data sets. With this approach an 80% change of successful fitting could be achieved even when using dose distributions constructed from only 20 to 30 aliquots. The median of the palaeodose distributions was approximately independent of the number of aliquots used. The modified method is then applied to samples from a sedimentary record in the northern Oman mountain range and the results compared with the method proposed by Fuchs and Lang [2001. OSL dating of coarse-grain fluvial quartz using single-aliquot protocols on sediments from NE Peleponnese, Greece. Quat. Sci. Rev. 20, 783-787]. It is concluded that the leading edge method proposed by Lepper and McKeever can be useful to derive D{sub E}'s from insufficiently bleached sediments even for a small number of aliquots if the Gaussian

  10. Water-equivalent one-dimensional scintillating fiber-optic dosimeter for measuring therapeutic photon beam

    International Nuclear Information System (INIS)

    Moon, Jinsoo; Won Jang, Kyoung; Jae Yoo, Wook; Han, Ki-Tek; Park, Jang-Yeon; Lee, Bongsoo

    2012-01-01

    In this study, we fabricated a one-dimensional scintillating fiber-optic dosimeter, which consists of 9 scintillating fiber-optic dosimeters, septa, and PMMA blocks for measuring surface and percentage depth doses of a therapeutic photon beam. Each dosimeter embedded in the 1-D scintillating fiber-optic dosimeter is composed of square type organic scintillators and plastic optical fibers. Also black PVC films are used as septa to minimize cross-talk between the scintillating fiber-optic dosimeters. To construct a dosimeter system, a 1-D scintillating fiber-optic dosimeter and a CMOS image sensor were combined with 20 m-length plastic optical fibers. Using the dosimeter system, we measured surface and percentage depth doses of 6 and 15 MV photon beams and compared the results with those of EBT films and an ionization chamber. - Highlights: ► Fabrication of a one-dimensional scintillating fiber-optic dosimeter. ► The one-dimensional scintillating fiber-optic dosimeter has 9 scintillating fiber-optic dosimeters. ► Measurements of surface and percentage depth doses of a therapeutic photon beam. ► The results were compared with those of EBT films and an ionization chamber.

  11. Radiation dose distribution measured in hydrogels containing ferrous ions

    International Nuclear Information System (INIS)

    Jin Tao; Murat, A.Q.; Liu Shilian; Duan Shengrong

    1990-01-01

    By the aid of nuclear magnetic resonance and dual wavelength TLC scanner, the absorbed dose distribution in hydrogels containing ferrous sulfate has been measured. The result shows a good straight line between the proton longitudinal relaxation rate and absorbed dose up to 16 Gy in agarose gels. It appeared that thin layer of acrylamide is much better than film for obtaining smooth dose curves

  12. Ambient dose measurement and personal dosimetry in nuclear medicine

    International Nuclear Information System (INIS)

    Friedrich, W.

    1992-01-01

    The dose measurements reported were performed with TLD dosemeters consisting of two glass tubes filled with CaSO 4 :TM powder. The measurements were done around a positron emission tomograph, in a nuclear medicine outpatient department, and in a hospital (therapy with unsealed radioactive substances). The personal doses measured during the campaign reported did not exceed the range of radiation doses and its fluctuations due to natural radiation exposure of the population. (DG) [de

  13. Measurement of the first Townsend ionization coefficient in a methane-based tissue-equivalent gas

    Energy Technology Data Exchange (ETDEWEB)

    Petri, A.R. [Instituto de Pesquisas Energéticas e Nucleares, Cidade Universitária, 05508-000 São Paulo (Brazil); Gonçalves, J.A.C. [Instituto de Pesquisas Energéticas e Nucleares, Cidade Universitária, 05508-000 São Paulo (Brazil); Departamento de Física, Pontifícia Universidade Católica de São Paulo, 01303-050 São Paulo (Brazil); Mangiarotti, A. [Instituto de Física - Universidade de São Paulo, Cidade Universitária, 05508-080 São Paulo (Brazil); Botelho, S. [Instituto de Pesquisas Energéticas e Nucleares, Cidade Universitária, 05508-000 São Paulo (Brazil); Bueno, C.C., E-mail: ccbueno@ipen.br [Instituto de Pesquisas Energéticas e Nucleares, Cidade Universitária, 05508-000 São Paulo (Brazil)

    2017-03-21

    Tissue-equivalent gases (TEGs), often made of a hydrocarbon, nitrogen, and carbon dioxide, have been employed in microdosimetry for decades. However, data on the first Townsend ionization coefficient (α) in such mixtures are scarce, regardless of the chosen hydrocarbon. In this context, measurements of α in a methane-based tissue-equivalent gas (CH{sub 4} – 64.4%, CO{sub 2} – 32.4%, and N{sub 2} – 3.2%) were performed in a uniform field configuration for density-normalized electric fields (E/N) up to 290 Td. The setup adopted in our previous works was improved for operating at low pressures. The modifications introduced in the apparatus and the experimental technique were validated by comparing our results of the first Townsend ionization coefficient in nitrogen, carbon dioxide, and methane with those from the literature and Magboltz simulations. The behavior of α in the methane-based TEG was consistent with that observed for pure methane. All the experimental results are included in tabular form in the .

  14. Race/Ethnicity and Measurement Equivalence of the Everyday Discrimination Scale

    Science.gov (United States)

    Kim, Giyeon; Sellbom, Martin; Ford, Katy-Lauren

    2014-01-01

    The present study examines the effect of race/ethnicity on measurement equivalence of the Everyday Discrimination Scale (EDS). Drawn from the Collaborative Psychiatric Epidemiology Surveys (CPES), adults aged 18 and older from four racial/ethnic groups were selected for analyses: 884 non-Hispanic Whites, 4,950 Blacks, 2,733 Hispanics/Latinos, and 2,089 Asians. Multiple-group confirmatory factor analyses were conducted. After adjusting for age and gender, the underlying construct of the EDS was invariant across four racial/ethnic groups, with Item 7 (“People act as if they’re better than you are”) associated with lower intercepts for the Hispanic/Latino and Asian groups relative to the non-Hispanic White and Black groups. In terms of latent factor differences, Blacks tended to score higher on the latent construct compared to other racial/ethnic groups, whereas Asians tended to score lower on the latent construct compared to Whites and Hispanics/Latinos. Findings suggest that although the EDS in general assesses the underlying construct of perceived discrimination equivalently across diverse racial/ethnic groups, caution is needed when Item 7 is used among Hispanics/Latinos or Asians. Implications are discussed in cultural and methodological contexts. PMID:24708076

  15. Race/ethnicity and measurement equivalence of the Everyday Discrimination Scale.

    Science.gov (United States)

    Kim, Giyeon; Sellbom, Martin; Ford, Katy-Lauren

    2014-09-01

    The present study examines the effect of race/ethnicity on measurement equivalence of the Everyday Discrimination Scale (EDS; Williams, Yu, Jackson, & Anderson, 1997). Drawn from the Collaborative Psychiatric Epidemiology Surveys (CPES; Alegría, Jackson, Kessler, & Takeuchi, 2008), adults aged 18 and older from four racial/ethnic groups were selected for analyses: 884 non-Hispanic Whites, 4,950 Blacks, 2,733 Hispanics/Latinos, and 2,089 Asians. Multiple-group confirmatory factor analyses were conducted. After adjusting for age and gender, the underlying construct of the EDS was invariant across four racial/ethnic groups, with Item 7 ("People act as if they're better than you are") associated with lower intercepts for the Hispanic/Latino and Asian groups relative to the non-Hispanic White and Black groups. In terms of latent factor differences, Blacks tended to score higher on the latent construct compared to other racial/ethnic groups, whereas Asians tended to score lower on the latent construct compared to Whites and Hispanics/Latinos. Findings suggest that although the EDS in general assesses the underlying construct of perceived discrimination equivalently across diverse racial/ethnic groups, caution is needed when Item 7 is used among Hispanics/Latinos or Asians. Implications are discussed in cultural and methodological contexts. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  16. Radiation dose measurements in intravenous pyelography

    International Nuclear Information System (INIS)

    Egeblad, M.; Gottlieb, E.

    1975-01-01

    Intravenous pyelography (IVP) and micturition cystourethrography (MCU) are the standard procedures in the radiological examination of children with urinary tract infections and in the control of these children. Gonad protection against radiation is not possible in MCU, but concerning the girls partly possible in IVP. It is of major importance to know the radiation dose in these procedures, especially since the examination is often repeated in the same patients. All IVP were done by means of the usual technique including possible gonad protection. The thermoluminescence dosimeter was placed rectally in the girls and fixed on the scrota in the boys. A total of 50 children was studied. Gonad dose ranged from 140 to 200mR in the girls and from 20 to 70mR in the boys (mean values). The radiation dose in IVP is very low compared to that of MCU, and from this point of view IVP is a dose saving examination in the control of children with urinary tract infections [fr

  17. Global real-time dose measurements using the Automated Radiation Measurements for Aerospace Safety (ARMAS) system

    Science.gov (United States)

    Tobiska, W. Kent; Bouwer, D.; Smart, D.; Shea, M.; Bailey, J.; Didkovsky, L.; Judge, K.; Garrett, H.; Atwell, W.; Gersey, B.; Wilkins, R.; Rice, D.; Schunk, R.; Bell, D.; Mertens, C.; Xu, X.; Wiltberger, M.; Wiley, S.; Teets, E.; Jones, B.; Hong, S.; Yoon, K.

    2016-11-01

    The Automated Radiation Measurements for Aerospace Safety (ARMAS) program has successfully deployed a fleet of six instruments measuring the ambient radiation environment at commercial aircraft altitudes. ARMAS transmits real-time data to the ground and provides quality, tissue-relevant ambient dose equivalent rates with 5 min latency for dose rates on 213 flights up to 17.3 km (56,700 ft). We show five cases from different aircraft; the source particles are dominated by galactic cosmic rays but include particle fluxes for minor radiation periods and geomagnetically disturbed conditions. The measurements from 2013 to 2016 do not cover a period of time to quantify galactic cosmic rays' dependence on solar cycle variation and their effect on aviation radiation. However, we report on small radiation "clouds" in specific magnetic latitude regions and note that active geomagnetic, variable space weather conditions may sufficiently modify the magnetospheric magnetic field that can enhance the radiation environment, particularly at high altitudes and middle to high latitudes. When there is no significant space weather, high-latitude flights produce a dose rate analogous to a chest X-ray every 12.5 h, every 25 h for midlatitudes, and every 100 h for equatorial latitudes at typical commercial flight altitudes of 37,000 ft ( 11 km). The dose rate doubles every 2 km altitude increase, suggesting a radiation event management strategy for pilots or air traffic control; i.e., where event-driven radiation regions can be identified, they can be treated like volcanic ash clouds to achieve radiation safety goals with slightly lower flight altitudes or more equatorial flight paths.

  18. Determination of the equivalent doses due to the ingestion of radionuclides from the uranium and thorium series presents in drinking waters of the region of Santa Luzia, Paraiba state, Brazil

    International Nuclear Information System (INIS)

    Pastura, Valeria F. da S.; Campos, Thomas F. da C.; Petta, Reinaldo A.

    2011-01-01

    This paper determined the original dose equivalents from radionuclides of uranium and thorium series in a drinking water of well which is supplied to the population of Santa Luzia, Paraiba state, Brazil. The collected waters are near to the mineralized phlegmatic bodies in rose quartz and amazonite feldspar. Radiometric measurements performed on the feldspar vein point out counting ratios surrounding 30000 cps and the analysis of collected samples of minerals presented tenors for the 226 Ra and 219 Pb varying from 0.50 to 2.30 Bq/sw. For determination of concentration of radionuclides U Total , 226 Ra, 228 Ra and 219 Pb, found in the not desalinated, two methods were used, spectrophotometry with arsenazo and radiochemistry, both realized in the CNEN-LAPOC laboratories. For the calculation of dose equivalent it was taken into consideration the following parameters: the dose coefficients for incorporation by ingestion for public individuals with ages over 17 years (Norma CNEN-NN-3.01, Regulatory Position 3.01/011) and daily ingestion of 4 liters of water, which is over the recommended by the WHO of 2L/day - 1993. The obtained values were compared with the reference value for compromised dose equivalent established by WHO for evaluate the risk potential to the health of population, by ingestion. The radionuclide concentrations in the wells varies from 0.054 to 0.21 Bq/L, resulting dose equivalents of 3.94 x 10 -3 mSv/year and 0.17 mSv/year in the studied population

  19. Measured neutron and gamma spectra from californium-252 in a tissue-equivalent medium.

    Science.gov (United States)

    Elson, H R; Stupar, T A; Shapiro, A; Kereiakes, J G

    1979-01-01

    A method of experimentally obtaining both neutron and gamma-ray spectra in a scattering medium is described. The method utilizes a liquid-organic scintillator (NE-213) coupled with a pulse-shape discrimination circuit. This allows the separation of the neutron-induced pulse-height data from the gamma-ray pulse-height data. Using mathematical unfolding techniques, the two sets of pulse-height data were transformed to obtain the neutron and gamma-ray energy spectra. A small spherical detector was designed and constructed to reduce the errors incurred by attempting spectral measurements in a scattering medium. Demonstration of the utility of the system to obtain the neutron and gamma-ray spectra in a scattering medium was performed by characterizing the neutron and gamma-ray spectra at various sites about a 3.7-microgram (1.5 cm active length) californium-252 source in a tissue-equivalent medium.

  20. Estimation of equivalent dose and its uncertainty in the OSL SAR protocol when count numbers do not follow a Poisson distribution

    International Nuclear Information System (INIS)

    Bluszcz, Andrzej; Adamiec, Grzegorz; Heer, Aleksandra J.

    2015-01-01

    The current work focuses on the estimation of equivalent dose and its uncertainty using the single aliquot regenerative protocol in optically stimulated luminescence measurements. The authors show that the count numbers recorded with the use of photomultiplier tubes are well described by negative binomial distributions, different ones for background counts and photon induced counts. This fact is then exploited in pseudo-random count number generation and simulations of D e determination assuming a saturating exponential growth. A least squares fitting procedure is applied using different types of weights to determine whether the obtained D e 's and their error estimates are unbiased and accurate. A weighting procedure is suggested that leads to almost unbiased D e estimates. It is also shown that the assumption of Poisson distribution in D e estimation may lead to severe underestimation of the D e error. - Highlights: • Detailed analysis of statistics of count numbers in luminescence readers. • Generation of realistically scattered pseudo-random numbers of counts in luminescence measurements. • A practical guide for stringent analysis of D e values and errors assessment.

  1. Evolution of water equivalent phantoms

    International Nuclear Information System (INIS)

    Yabutani, Toshimine; Ida, Yoshihiro; Sawada, Takeshi

    1998-01-01

    In radiation therapy, the dose absorbed by the target tissue needs to be extremely accurate. In order to obtain the target absorbed dose, radiation dose measurements are performed using a phantom instead of the patient's body, because the target absorbed dose cannot be directly measured. Although water is the best human muscle equivalent phantom, it is not useful for this purpose. Therefore, water equivalent solid phantoms are usually used for the measurements. We compared the following water equivalent solid phantoms for water: Tough water phantom, 457 Solid water phantom, RW-3, Mix-DP, polystyrene resin, polyethylene resin, and acrylic resin. The measurements obtained were ionization current in the phantoms as determined by ionization chamber, tissue-maximum ratio, transmission measurements in water with and without the phantoms, Hounsfield units of the phantoms for uniformity of inside phantoms as determined by computed tomography, and accuracy of the phantoms. Results showed the phantoms to be almost equivalent to water, except for the acrylic resin phantom. However, the phantoms had various characteristics that affected accuracy, and the phantoms underwent change with time. Measurement error was caused by the characteristics of the phantoms. Therefore, it is important to measure the calibration coefficient of phantoms for water, regardless of what is stated on paper. (author)

  2. Measuring snow water equivalent from common-offset GPR records through migration velocity analysis

    Science.gov (United States)

    St. Clair, James; Holbrook, W. Steven

    2017-12-01

    Many mountainous regions depend on seasonal snowfall for their water resources. Current methods of predicting the availability of water resources rely on long-term relationships between stream discharge and snowpack monitoring at isolated locations, which are less reliable during abnormal snow years. Ground-penetrating radar (GPR) has been shown to be an effective tool for measuring snow water equivalent (SWE) because of the close relationship between snow density and radar velocity. However, the standard methods of measuring radar velocity can be time-consuming. Here we apply a migration focusing method originally developed for extracting velocity information from diffracted energy observed in zero-offset seismic sections to the problem of estimating radar velocities in seasonal snow from common-offset GPR data. Diffractions are isolated by plane-wave-destruction (PWD) filtering and the optimal migration velocity is chosen based on the varimax norm of the migrated image. We then use the radar velocity to estimate snow density, depth, and SWE. The GPR-derived SWE estimates are within 6 % of manual SWE measurements when the GPR antenna is coupled to the snow surface and 3-21 % of the manual measurements when the antenna is mounted on the front of a snowmobile ˜ 0.5 m above the snow surface.

  3. Measuring snow water equivalent from common-offset GPR records through migration velocity analysis

    Directory of Open Access Journals (Sweden)

    J. St. Clair

    2017-12-01

    Full Text Available Many mountainous regions depend on seasonal snowfall for their water resources. Current methods of predicting the availability of water resources rely on long-term relationships between stream discharge and snowpack monitoring at isolated locations, which are less reliable during abnormal snow years. Ground-penetrating radar (GPR has been shown to be an effective tool for measuring snow water equivalent (SWE because of the close relationship between snow density and radar velocity. However, the standard methods of measuring radar velocity can be time-consuming. Here we apply a migration focusing method originally developed for extracting velocity information from diffracted energy observed in zero-offset seismic sections to the problem of estimating radar velocities in seasonal snow from common-offset GPR data. Diffractions are isolated by plane-wave-destruction (PWD filtering and the optimal migration velocity is chosen based on the varimax norm of the migrated image. We then use the radar velocity to estimate snow density, depth, and SWE. The GPR-derived SWE estimates are within 6 % of manual SWE measurements when the GPR antenna is coupled to the snow surface and 3–21 % of the manual measurements when the antenna is mounted on the front of a snowmobile  ∼  0.5 m above the snow surface.

  4. Measurement of gamma radiation doses in nuclear power plant environment

    International Nuclear Information System (INIS)

    Bochvar, I.A.; Keirim-Markus, I.B.; Sergeeva, N.A.

    1976-01-01

    Considered are the problems of measuring gamma radiation dose values and the dose distribution in the nuclear power plant area with the aim of estimating the extent of their effect on the population. Presented are the dosimeters applied, their distribution throughout the controlled area, time of measurement. The distribution of gamma radiation doses over the controlled area and the dose alteration with the increase of the distance from the release source are shown. The results of measurements are investigated. The conclusion is made that operating nuclear power plants do not cause any increase in the gamma radiation dose over the area. Recommendations for clarifying the techniques for using dose-meters and decreasing measurement errors are given [ru

  5. The Australian Commonwealth standard of measurement for absorbed radiation dose

    International Nuclear Information System (INIS)

    Sherlock, S.L.

    1990-06-01

    This report documents the absorbed dose standard for photon beams in the range from 1 to 25 MeV. Measurements of absorbed dose in graphite irradiated by a beam of cobalt-60 gamma rays from an Atomic Energy of Canada Limited (AECL) E1 Dorado 6 teletherapy unit are reported. The measurements were performed using a graphite calorimeter, which is the primary standard for absorbed dose. The measurements are used to calibrate a working standard ion chamber in terms of absorbed dose in graphite. Details of the methods, results and correction factors applied are given in Appendices. 13 refs., 6 tabs., 6 figs

  6. Thyroid equivalent dose in staffs that use neck lead protector in pediatric barium meal; Dose equivalente na tireoide dos profissionais que utilizam o protetor plumbifero nos exames de seed pediatrico

    Energy Technology Data Exchange (ETDEWEB)

    Filipov, Danielle; Sauzen, Jessica; Paschuk, Sergei A., E-mail: dfilipov@utfpr.edu.br [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Schelin, Hugo R.; Denyak, Valeriy [Instituto de Pesquisa Pele Pequeno Principe (IPPP), Curitiba, PR (Brazil); Legnani, Adriano [Hospital Pequeno Principe, Curitiba, PR (Brazil)

    2015-08-15

    The aim of this study is to estimate the thyroid equivalent dose in staffs that perform pediatric barium meal procedures and use neck lead protector. Thermoluminescent Dosimeters (TLDs) were positioned on the lead protectors, used by two professionals. After that, a solid state detector was exposed (with and without the protector above it). Therefore, it was possible to obtain both lead protectors attenuation factors. At the end, average and annual doses received by the TLDs and the thyroid (applying the attenuation factor over the dosimeters doses) were obtained. It was found that the average and annual equivalent doses in the thyroid gland are, respectively, higher than in comparative studies and within the established limits. With these data, it is concluded that the application of radiation protection optimization techniques is required. (author)

  7. Dental radiography: tooth enamel EPR dose assessment from Rando phantom measurements

    International Nuclear Information System (INIS)

    Aragno, D.; Fattibene, P.; Onori, S.

    2000-01-01

    Electron paramagnetic resonance dosimetry of tooth enamel is now established as a suitable method for individual dose reconstruction following radiation accidents. The accuracy of the method is limited by some confounding factors, among which is the dose received due to medical x-ray irradiation. In the present paper the EPR response of tooth enamel to endoral examination was experimentally evaluated using an anthropomorphic phantom. The dose to enamel for a single exposure of a typical dental examination performed with a new x-ray generation unit working at 65 kVp gave rise to a CO 2 -signal of intensity similar to that induced by a dose of about 2 mGy of 60 Co. EPR measurements were performed on the entire tooth with no attempt to separate buccal and lingual components. Also the dose to enamel for an orthopantomography exam was estimated. It was derived from TLD measurements as equivalent to 0.2 mGy of 60 Co. In view of application to risk assessment analysis, in the present work the value for the ratio of the reference dose at the phantom surface measured with TLD to the dose at the tooth measured with EPR was determined. (author)

  8. Reliability of equivalent-dose determination and age-models in the OSL dating of historical and modern palaeoflood sediments

    DEFF Research Database (Denmark)

    Medialdea, Alicia; Thomsen, Kristina Jørkov; Murray, Andrew Sean

    2014-01-01

    of minimum over-dispersion (OD) is based on dose recovery tests based on gamma-irradiated samples. We then present a detailed analysis of the effect of an additional uncertainty added to the individual dose estimates on the burial dose estimates from the MAM and the IEU approach. The results of the various...

  9. Rotor equivalent wind speed for power curve measurement - comparative exercise for IEA Wind Annex 32

    Science.gov (United States)

    Wagner, R.; Cañadillas, B.; Clifton, A.; Feeney, S.; Nygaard, N.; Poodt, M.; St. Martin, C.; Tüxen, E.; Wagenaar, J. W.

    2014-06-01

    A comparative exercise has been organised within the International Energy Agency (IEA) Wind Annex 32 in order to test the Rotor Equivalent Wind Speed (REWS) method under various conditions of wind shear and measurement techniques. Eight organisations from five countries participated in the exercise. Each member of the group has derived both the power curve based on the wind speed at hub height and the power curve based on the REWS. This yielded results for different wind turbines, located in diverse types of terrain and where the wind speed profile was measured with different instruments (mast or various lidars). The participants carried out two preliminary steps in order to reach consensus on how to implement the REWS method. First, they all derived the REWS for one 10 minute wind speed profile. Secondly, they all derived the power curves for one dataset. The main point requiring consensus was the definition of the segment area used as weighting for the wind speeds measured at the various heights in the calculation of the REWS. This comparative exercise showed that the REWS method results in a significant difference compared to the standard method using the wind speed at hub height in conditions with large shear and low turbulence intensity.

  10. Dose-area product measurements during Barium enema radiograph ...

    African Journals Online (AJOL)

    The aim of this study was to obtain a direct measurement of the typical dose delivered to an average adult patient during a barium enema examination. Measurement was done on a sample of 50 patients at three departments, using a dose-area product (DAP) meter. The comparison of the results with UK median levels ...

  11. Measurement of dose distribution in the spherical phantom onboard the ISS-KIBO module -MATROSHKA-R in KIBO-

    Science.gov (United States)

    Kodaira, Satoshi; Kawashima, Hajime; Kurano, Mieko; Uchihori, Yukio; Nikolaev, Igor; Ambrozova, Iva; Kitamura, Hisashi; Kartsev, Ivan; Tolochek, Raisa; Shurshakov, Vyacheslav

    The measurement of dose equivalent and effective dose during manned space missions on the International Space Station (ISS) is important for evaluating the risk to astronaut health and safety when exposed to space radiation. The dosimetric quantities are constantly changing and strongly depend on the level of solar activity and the various spacecraft- and orbit-dependent parameters such as the shielding distribution in the ISS module, location of the spacecraft within its orbit relative to the Earth, the attitude (orientation) and altitude. Consequently, the continuous monitoring of dosimetric quantities is required to record and evaluate the personal radiation dose for crew members during spaceflight. The dose distributions in the phantom body and on its surface give crucial information to estimate the dose equivalent in the human body and effective dose in manned space mission. We have measured the absorbed dose and dose equivalent rates using passive dosimeters installed in the spherical phantom in Japanese Experiment Module (“KIBO”) of the ISS in the framework of Matroshka-R space experiment. The exposure duration was 114 days from May 21 to September 12, 2012. The phantom consists of tissue-equivalent material covered with a poncho jacket with 32 pockets on its surface and 20 container rods inside of the phantom. The phantom diameter is 35 cm and the mass is 32 kg. The passive dosimeters consisted of a combination of luminescent detectors of Al _{2}O _{3};C OSL and CaSO _{4}:Dy TLD and CR-39 plastic nuclear track detectors. As one of preliminary results, the dose distribution on the phantom surface measured with OSL detectors installed in the jacket pockets is found to be ranging from 340 muGy/day to 260 muGy/day. In this talk, we will present the detail dose distributions, and variations of LET spectra and quality factor obtained outside and inside of the spherical phantom installed in the ISS-KIBO.

  12. SFACTOR: a computer code for calculating dose equivalent to a target organ per microcurie-day residence of a radionuclide in a source organ

    International Nuclear Information System (INIS)

    Dunning, D.E. Jr.; Pleasant, J.C.; Killough, G.G.

    1977-11-01

    A computer code SFACTOR was developed to estimate the average dose equivalent S (rem/μCi-day) to each of a specified list of target organs per microcurie-day residence of a radionuclide in source organs in man. Source and target organs of interest are specified in the input data stream, along with the nuclear decay information. The SFACTOR code computes components of the dose equivalent rate from each type of decay present for a particular radionuclide, including alpha, electron, and gamma radiation. For those transuranic isotopes which also decay by spontaneous fission, components of S from the resulting fission fragments, neutrons, betas, and gammas are included in the tabulation. Tabulations of all components of S are provided for an array of 22 source organs and 24 target organs for 52 radionuclides in an adult

  13. Collective dose as a performance measure for occupational radiation protection programs: Issues and recommendations

    International Nuclear Information System (INIS)

    Strom, D.J.; Harty, R.; Hickey, E.E.; Martin, J.B.; Peffers, M.S.; Kathren, R.L.

    1998-07-01

    Collective dose is one of the performance measures used at many US Department of Energy (DOE) contractor facilities to quantitatively assess the objectives of the radiation protection program. It can also be used as a management tool to improve the program for keeping worker doses as low as reasonably achievable (ALARA). Collective dose is used here to mean the sum of all total effective dose equivalent values for all workers in a specified group over a specified time. It is often used as a surrogate estimate of radiological risk. In principle, improvements in radiation protection programs and procedures will result in reduction of collective dose, all other things being equal. Within the DOE, most frequently, a single collective dose number, which may or may not be adjusted for workload and other factors, is used as a performance measure for a contractor. The purpose of this report is to evaluate the use of collective dose as a performance measure for ALARA programs at DOE sites

  14. The measurement of patient doses from diagnostic x-rays

    International Nuclear Information System (INIS)

    Morris, N.D.; Solomon, S.B.

    1980-06-01

    As part of the National Health and Medical Research Council survey to determine the genetic and mean bone-marrow doses to the Australian population from the medical, dental and chiropractic uses of radiation sources, doses to patients undergoing X-ray diagnostic procedures were evaluated. The doses were measured using capsules of LiF or CaF 2 :Dy thermoluminescent dosemeters (TLD). The evaluation of the TLD measurements is described and the mean values of the skin doses for patients undergoing various radiographic examinations in Australia in 1970 are presented

  15. SU-E-T-365: Estimation of Neutron Ambient Dose Equivalents for Radioprotection Exposed Workers in Radiotherapy Facilities Based On Characterization Patient Risk Estimation

    Energy Technology Data Exchange (ETDEWEB)

    Irazola, L; Terron, J; Sanchez-Doblado, F [Departamento de Fisiologia Medica y Biofisica, Universidad de Sevilla (Spain); Servicio de Radiofisica, Hospital Universitario Virgen Macarena, Sevilla (Spain); Domingo, C; Romero-Exposito, M [Departament de Fisica, Universitat Autonoma de Barcelona, Bellaterra (Spain); Garcia-Fuste, M [Health and Safety Department, ALBA Synchrotron Light Source, Cerdanyola del Valles (Spain); Sanchez-Nieto, B [Instituto de Fisica, Pontificia Universidad Catolica de Chile, Santiago (Chile); Bedogni, R [Laboratori Nazionali di Frascati, Istituto Nazionale di Fisica Nucleare (INFN) (Italy)

    2015-06-15

    Purpose: Previous measurements with Bonner spheres{sup 1} showed that normalized neutron spectra are equal for the majority of the existing linacs{sup 2}. This information, in addition to thermal neutron fluences obtained in the characterization procedure{sup 3}3, would allow to estimate neutron doses accidentally received by exposed workers, without the need of an extra experimental measurement. Methods: Monte Carlo (MC) simulations demonstrated that the thermal neutron fluence distribution inside the bunker is quite uniform, as a consequence of multiple scatter in the walls{sup 4}. Although inverse square law is approximately valid for the fast component, a more precise calculation could be obtained with a generic fast fluence distribution map around the linac, from MC simulations{sup 4}. Thus, measurements of thermal neutron fluences performed during the characterization procedure{sup 3}, together with a generic unitary spectra{sup 2}, would allow to estimate the total neutron fluences and H*(10) at any point{sup 5}. As an example, we compared estimations with Bonner sphere measurements{sup 1}, for two points in five facilities: 3 Siemens (15–23 MV), Elekta (15 MV) and Varian (15 MV). Results: Thermal neutron fluences obtained from characterization, are within (0.2–1.6×10{sup 6}) cm−{sup 2}•Gy{sup −1} for the five studied facilities. This implies ambient equivalent doses ranging from (0.27–2.01) mSv/Gy 50 cm far from the isocenter and (0.03–0.26) mSv/Gy at detector location with an average deviation of ±12.1% respect to Bonner measurements. Conclusion: The good results obtained demonstrate that neutron fluence and H*(10) can be estimated based on: (a) characterization procedure established for patient risk estimation in each facility, (b) generic unitary neutron spectrum and (c) generic MC map distribution of the fast component. [1] Radiat. Meas (2010) 45: 1391 – 1397; [2] Phys. Med. Biol (2012) 5 7:6167–6191; [3] Med. Phys (2015) 42

  16. Measured dose to ovaries and testes from Hodgkin's fields and determination of genetically significant dose

    International Nuclear Information System (INIS)

    Niroomand-Rad, A.; Cumberlin, R.

    1993-01-01

    The purpose of this study was to determine the genetically significant dose from therapeutic radiation exposure with Hodgkin's fields by estimating the doses to ovaries and testes. Phantom measurements were performed to verify estimated doses to ovaries and testes from Hodgkin's fields. Thermoluminescent LiF dosimeters (TLD-100) of 1 x 3 x 3 mm 3 dimensions were embedded in phantoms and exposed to standard mantle and paraaortic fields using Co-60, 4 MV, 6 MV, and 10 MV photon beams. The results show that measured doses to ovaries and testes are about two to five times higher than the corresponding graphically estimated doses for Co-60 and 4 MVX photon beams as depicted in ICRP publication 44. In addition, the measured doses to ovaries and testes are about 30% to 65% lower for 10 MV photon beams than for their corresponding Co-60 photon beams. The genetically significant dose from Hodgkin's treatment (less than 0.01 mSv) adds about 4% to the genetically significant dose contribution to medical procedures and adds less than 1% to the genetically significant dose from all sources. Therefore, the consequence to society is considered to be very small. The consequences for the individual patient are, likewise, small. 28 refs., 3 figs., 5 tabs

  17. Variation in Dose Measurement for Glycine Dosimeter

    OpenAIRE

    Santosh H. Shinde; T. Mukherjee

    2011-01-01

    Glycine dosimeter based on spectrophotometric read-out method is being developed for radiation processing dosimetry. According to International Standards Organization (ISO), result of a measurement reported should always be accompanied with some quantitative indication of the quality of the result, which assures the reliability of the result. Without such an indication, measurement results cannot be compared, either among themselves or with reference value given in a specification or standard...

  18. Preliminary results of measurement of natural environmental radiation levels and doses to population in China

    International Nuclear Information System (INIS)

    Wang Qiliang; He Miaoting; Shu Qi

    1985-01-01

    In this paper the preliminary results of measurement of natural environmental radiation levels in China with RSS-111 high pressure ionization chamber and estimated doses to population are reported. A total of 2,723 indoor locales throughout China were measured. The results showed that the average absorbed dose rates in air due to gamma radiation for indoors and outdoors were 11.0 x 10 -8 Gy.h -1 and 7.4 x 10 -8 Gy.h -1 , respectively, and those due to cosmic rays were 3.2 x 10 -8 Gy.h -1 and 3.7 x 10 -8 Gy.h -1 , respectively. The annual average effective dose equivalent to population was 919 μSv, including 630 μSv from natural gamma radiation and 289 μSv from cosmic rays

  19. Comparison of whole-body phantom designs to estimate organ equivalent neutron doses for secondary cancer risk assessment in proton therapy

    International Nuclear Information System (INIS)

    Moteabbed, Maryam; Drenkhahn, Robert; Paganetti, Harald; Geyer, Amy; Bolch, Wesley E

    2012-01-01

    Secondary neutron fluence created during proton therapy can be a significant source of radiation exposure in organs distant from the treatment site, especially in pediatric patients. Various published studies have used computational phantoms to estimate neutron equivalent doses in proton therapy. In these simulations, whole-body patient representations were applied considering either generic whole-body phantoms or generic age- and gender-dependent phantoms. No studies to date have reported using patient-specific geometry information. The purpose of this study was to estimate the effects of patient–phantom matching when using computational pediatric phantoms. To achieve this goal, three sets of phantoms, including different ages and genders, were compared to the patients’ whole-body CT. These sets consisted of pediatric age-specific reference, age-adjusted reference and anatomically sculpted phantoms. The neutron equivalent dose for a subset of out-of-field organs was calculated using the GEANT4 Monte Carlo toolkit, where proton fields were used to irradiate the cranium and the spine of all phantoms and the CT-segmented patient models. The maximum neutron equivalent dose per treatment absorbed dose was calculated and found to be on the order of 0 to 5 mSv Gy −1 . The relative dose difference between each phantom and their respective CT-segmented patient model for most organs showed a dependence on how close the phantom and patient heights were matched. The weight matching was found to have much smaller impact on the dose accuracy except for very heavy patients. Analysis of relative dose difference with respect to height difference suggested that phantom sculpting has a positive effect in terms of dose accuracy as long as the patient is close to the 50th percentile height and weight. Otherwise, the benefit of sculpting was masked by inherent uncertainties, i.e. variations in organ shapes, sizes and locations. Other sources of uncertainty included errors

  20. The equivalence of two phylogenetic biodiversity measures: the Shapley value and Fair Proportion index.

    Science.gov (United States)

    Hartmann, Klaas

    2013-11-01

    Most biodiversity conservation programs are forced to prioritise species in order to allocate their funding. This paper contains a mathematical proof that provides biological support for one common approach based on phylogenetic indices. Phylogenetic trees describe the evolutionary relationships between a group of taxa. Two indices for computing the distinctiveness of each taxon in a phylogenetic tree are considered here-the Shapley value and the Fair Proportion index. These indices provide a measure of the importance of each taxon for overall biodiversity and have been used to prioritise taxa for conservation. The Shapley value is the biodiversity contribution a taxon is expected to make if all taxa are equally likely to become extinct. This interpretation makes it appealing to use the Shapley value in biodiversity conservation applications. The Fair Proportion index lacks a convenient interpretation, however it is significantly easier to calculate and understand. It has been empirically observed that there is a high correlation between the two indices. This paper shows the mathematical basis for this correlation and proves that as the number of taxa increases, the indices become equivalent. Consequently in biodiversity prioritisation the simpler Fair Proportion index can be used whilst retaining the appealing interpretation of the Shapley value.

  1. Uncertainty of dose measurement in radiation processing

    DEFF Research Database (Denmark)

    Miller, A.

    1996-01-01

    The major standard organizations of the world have addressed the issue of reporting uncertainties in measurement reports and certificates. There is, however, still some ambiguity in the minds of many people who try to implement the recommendations in real life. This paper is a contribution to the...

  2. An international intercomparison of absorbed dose measurements for radiation therapy

    International Nuclear Information System (INIS)

    Taiman Kadni; Noriah Mod Ali

    2002-01-01

    Dose intercomparison on an international basis has become an important component of quality assurance measurement i.e. to check the performance of absorbed dose measurements in radiation therapy. The absorbed dose to water measurements for radiation therapy at the SSDL, MINT have been regularly compared through international intercomparison programmes organised by the IAEA Dosimetry Laboratory, Seibersdorf, Austria such as IAEA/WHO TLD postal dose quality audits and the Intercomparison of therapy level ionisation chamber calibration factors in terms of air kerma and absorbed dose to water calibration factors. The results of these intercomparison in terms of percentage deviations for Cobalt 60 gamma radiation and megavoltage x-ray from medical linear accelerators participated by the SSDL-MINT during the year 1985-2001 are within the acceptance limit. (Author)

  3. Preliminary comparative assessment and elements of equivalence of air pollution measurement results of portable monitoring stations with using stochastic models

    Science.gov (United States)

    Owczarek, Tomasz; Rogulski, Mariusz; Badyda, Artur

    2018-01-01

    This article is an attempt to assess the suitability of new non-reference mobile measuring devices for the analysis of PM10 concentrations. The aim is to compare the concentration daily values measured by these devices with the concentrations obtained by the reference device. It also examines the possibility of building models that correct these values to equivalent reference values. The analysis allows to conclude that the properties of the obtained measurements indicate a good chance of constructing an effective model of correcting the concentration values. Comparison of frequency, time variation and correlation of concentrations indicates the ability to demonstrate the equivalence of mobile devices with the reference method.

  4. The minimum measurable dose of the sensitive Harshaw TLDs

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; German, U.; Naim, E.

    1991-01-01

    The TL-dose response was measured for the sensitive Harshaw manufactured phosphors (CaF 2 :Dy and CaF 2 :Tm), taking chips from the same batch and from different batches. The relative standard deviations were fitted to a semiempirical expression, from which the minimum measurable doses were derived and compared to the minimum measurable dose calculated by taking 3 times the standard deviation of unirradiated chips. The contribution of the individual calibration of each TLD chip was checked, as well

  5. SU-E-T-102: Determination of Dose Distributions and Water-Equivalence of MAGIC-F Polymer Gel for 60Co and 192Ir Brachytherapy Sources

    Energy Technology Data Exchange (ETDEWEB)

    Quevedo, A; Nicolucci, P [University of Sao Paulo, Ribeirao Preto, SP (Brazil)

    2014-06-01

    Purpose: Analyse the water-equivalence of MAGIC-f polymer gel for {sup 60}Co and {sup 192}Ir clinical brachytherapy sources, through dose distributions simulated with PENELOPE Monte Carlo code. Methods: The real geometry of {sup 60} (BEBIG, modelo Co0.A86) and {sup 192}192Ir (Varian, model GammaMed Plus) clinical brachytherapy sources were modelled on PENELOPE Monte Carlo simulation code. The most probable emission lines of photons were used for both sources: 17 emission lines for {sup 192}Ir and 12 lines for {sup 60}. The dose distributions were obtained in a cubic water or gel homogeneous phantom (30 × 30 × 30 cm{sup 3}), with the source positioned in the middle of the phantom. In all cases the number of simulation showers remained constant at 10{sup 9} particles. A specific material for gel was constructed in PENELOPE using weight fraction components of MAGIC-f: wH = 0,1062, wC = 0,0751, wN = 0,0139, wO = 0,8021, wS = 2,58×10{sup −6} e wCu = 5,08 × 10{sup −6}. The voxel size in the dose distributions was 0.6 mm. Dose distribution maps on the longitudinal and radial direction through the centre of the source were used to analyse the water-equivalence of MAGIC-f. Results: For the {sup 60} source, the maximum diferences in relative doses obtained in the gel and water were 0,65% and 1,90%, for radial and longitudinal direction, respectively. For {sup 192}Ir, the maximum difereces in relative doses were 0,30% and 1,05%, for radial and longitudinal direction, respectively. The materials equivalence can also be verified through the effective atomic number and density of each material: Zef-MAGIC-f = 7,07 e .MAGIC-f = 1,060 g/cm{sup 3} and Zef-water = 7,22. Conclusion: The results showed that MAGIC-f is water equivalent, consequently being suitable to simulate soft tissue, for Cobalt and Iridium energies. Hence, gel can be used as a dosimeter in clinical applications. Further investigation to its use in a clinical protocol is needed.

  6. Phantoms for IMRT dose distribution measurement and treatment verification

    International Nuclear Information System (INIS)

    Low, Daniel A.; Gerber, Russell L.; Mutic, Sasa; Purdy, James A.

    1998-01-01

    Background: The verification of intensity-modulated radiation therapy (IMRT) patient treatment dose distributions is currently based on custom-built or modified dose measurement phantoms. The only commercially available IMRT treatment planning and delivery system (Peacock, NOMOS Corp.) is supplied with a film phantom that allows accurate spatial localization of the dose distribution using radiographic film. However, measurements using other dosimeters are necessary for the thorough verification of IMRT. Methods: We have developed a phantom to enable dose measurements using a cylindrical ionization chamber and the localization of prescription isodose curves using a matrix of thermoluminescent dosimetry (TLD) chips. The external phantom cross-section is identical to that of the commercial phantom, to allow direct comparisons of measurements. A supplementary phantom has been fabricated to verify the IMRT dose distributions for pelvis treatments. Results: To date, this phantom has been used for the verification of IMRT dose distributions for head and neck and prostate cancer treatments. Designs are also presented for a phantom insert to be used with polymerizing gels (e.g., BANG-2) to obtain volumetric dose distribution measurements. Conclusion: The phantoms have proven useful in the quantitative evaluation of IMRT treatments

  7. Ultralow dose CT for pulmonary nodule detection with chest X-ray equivalent dose - a prospective intra-individual comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Messerli, Michael [University Zurich, Department of Nuclear Medicine, University Hospital Zurich, Zurich (Switzerland); Cantonal Hospital St. Gallen, Division of Radiology and Nuclear Medicine, St. Gallen (Switzerland); Kluckert, Thomas; Knitel, Meinhard; Desbiolles, Lotus; Bauer, Ralf W.; Wildermuth, Simon [Cantonal Hospital St. Gallen, Division of Radiology and Nuclear Medicine, St. Gallen (Switzerland); Waelti, Stephan [Cantonal Hospital St. Gallen, Division of Radiology and Nuclear Medicine, St. Gallen (Switzerland); University of Montreal, Department of Radiology, CHU Sainte-Justine, Montreal, Quebec (Canada); Rengier, Fabian [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Warschkow, Rene [Cantonal Hospital St. Gallen, Department of Surgery, St. Gallen (Switzerland); Alkadhi, Hatem [University Zurich, Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich (Switzerland); Leschka, Sebastian [Cantonal Hospital St. Gallen, Division of Radiology and Nuclear Medicine, St. Gallen (Switzerland); University Zurich, Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich (Switzerland)

    2017-08-15

    To prospectively evaluate the accuracy of ultralow radiation dose CT of the chest with tin filtration at 100 kV for pulmonary nodule detection. 202 consecutive patients undergoing clinically indicated chest CT (standard dose, 1.8 ± 0.7 mSv) were prospectively included and additionally scanned with an ultralow dose protocol (0.13 ± 0.01 mSv). Standard dose CT was read in consensus by two board-certified radiologists to determine the presence of lung nodules and served as standard of reference (SOR). Two radiologists assessed the presence of lung nodules and their locations on ultralow dose CT. Sensitivity and specificity of the ultralow dose protocol was compared against the SOR, including subgroup analyses of different nodule sizes and types. A mixed effects logistic regression was used to test for independent predictors for sensitivity of pulmonary nodule detection. 425 nodules (mean diameter 3.7 ± 2.9 mm) were found on SOR. Overall sensitivity for nodule detection by ultralow dose CT was 91%. In multivariate analysis, nodule type, size and patients BMI were independent predictors for sensitivity (p < 0.001). Ultralow dose chest CT at 100 kV with spectral shaping enables a high sensitivity for the detection of pulmonary nodules at exposure levels comparable to plain film chest X-ray. (orig.)

  8. Computer-aided detection (CAD) of solid pulmonary nodules in chest x-ray equivalent ultralow dose chest CT - first in-vivo results at dose levels of 0.13 mSv

    Energy Technology Data Exchange (ETDEWEB)

    Messerli, Michael, E-mail: Michael.Messerli@usz.ch [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland); Kluckert, Thomas; Knitel, Meinhard [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland); Rengier, Fabian [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg (Germany); Warschkow, René [Department of Surgery, Cantonal Hospital St. Gallen (Switzerland); Alkadhi, Hatem [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich (Switzerland); Leschka, Sebastian [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland); Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich (Switzerland); Wildermuth, Simon; Bauer, Ralf W. [Division of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen (Switzerland)

    2016-12-15

    of CAD (p < 0.001), and nodule size (p < 0.0001) were independent predictors for nodule detection, but not BMI (p = 0.933) and the use of contrast agents (p = 0.176). Conclusions: Computer-aided detection of solid pulmonary nodules using ultralow dose CT with chest X-ray equivalent radiation dose has similar sensitivities to those from standard dose CT. Adding CAD in ultralow dose CT significantly improves the sensitivity of radiologists.

  9. Computer-aided detection (CAD) of solid pulmonary nodules in chest x-ray equivalent ultralow dose chest CT - first in-vivo results at dose levels of 0.13 mSv

    International Nuclear Information System (INIS)

    Messerli, Michael; Kluckert, Thomas; Knitel, Meinhard; Rengier, Fabian; Warschkow, René; Alkadhi, Hatem; Leschka, Sebastian; Wildermuth, Simon; Bauer, Ralf W.

    2016-01-01

    of CAD (p < 0.001), and nodule size (p < 0.0001) were independent predictors for nodule detection, but not BMI (p = 0.933) and the use of contrast agents (p = 0.176). Conclusions: Computer-aided detection of solid pulmonary nodules using ultralow dose CT with chest X-ray equivalent radiation dose has similar sensitivities to those from standard dose CT. Adding CAD in ultralow dose CT significantly improves the sensitivity of radiologists.

  10. Student's music exposure: Full-day personal dose measurements.

    Science.gov (United States)

    Washnik, Nilesh Jeevandas; Phillips, Susan L; Teglas, Sandra

    2016-01-01

    Previous studies have shown that collegiate level music students are exposed to potentially hazardous sound levels. Compared to professional musicians, collegiate level music students typically do not perform as frequently, but they are exposed to intense sounds during practice and rehearsal sessions. The purpose of the study was to determine the full-day exposure dose including individual practice and ensemble rehearsals for collegiate student musicians. Sixty-seven college students of classical music were recruited representing 17 primary instruments. Of these students, 57 completed 2 days of noise dose measurements using Cirrus doseBadge programed according to the National Institute for Occupational Safety and Health criterion. Sound exposure was measured for 2 days from morning to evening, ranging from 7 to 9 h. Twenty-eight out of 57 (49%) student musicians exceeded a 100% daily noise dose on at least 1 day of the two measurement days. Eleven student musicians (19%) exceeded 100% daily noise dose on both days. Fourteen students exceeded 100% dose during large ensemble rehearsals and eight students exceeded 100% dose during individual practice sessions. Approximately, half of the student musicians exceeded 100% noise dose on a typical college schedule. This finding indicates that a large proportion of collegiate student musicians are at risk of developing noise-induced hearing loss due to hazardous sound levels. Considering the current finding, there is a need to conduct hearing conservation programs in all music schools, and to educate student musicians about the use and importance of hearing protection devices for their hearing.

  11. Real-time personal dose measurement and management system

    International Nuclear Information System (INIS)

    Zhang Zhiyong; Cheng Chang; Liu Zhengshan; Yang Huating; Deng Changming; Zhang Xiu; Guo Zhanjie

    2001-01-01

    The composition and design of a real-time personal dose measurement and management system are described. Accordingly, some pertinent hardware circuits and software codes including their operation modes are presented

  12. Dose measurements in pediatric radiology in state of Sergipe, BR

    International Nuclear Information System (INIS)

    Azevedo, J.P.A.; Magalhaes, C.M.S.; Souza, D.N.

    2004-01-01

    Dose measurements are acknowledged to be a vital part of the quality assurance process in diagnostic radiology, and the use of thermoluminescent dosimeters (TLD) is a recommended method of entrance dose quantification. Measurement of doses in radiographic examinations is widely adopted in clinical practice for adults as well as for children. Phantoms can be used to simulate different parts of the body, depending on the materials used to build them. In this work three different sets of phantoms have been prepared with acrylic blocks to simulate thorax children of different ages. The dosimetric measurements have been carried out using TLD and an ionising chamber. Measurements were realised in two X-rays equipment in Aracaju, Brazil. The entrance, half depth and exit surface doses were analysed. (author)

  13. High-temperature absorbed dose measurements in the megagray range

    International Nuclear Information System (INIS)

    Balian, P.; Ardonceau, J.; Zuppiroli, L.

    1988-01-01

    Organic conductors of the tetraselenotetracene family have been tested as ''high-temperature'' absorbed dose dosimeters. They were heated up to 120 0 C and irradiated at this temperature with 1-MeV electrons in order to simulate, in a short time, a much longer γ-ray irradiation. The electric resistance increase of the crystal can be considered a good measurement of the absorbed dose in the range 10 6 Gy to a few 10 8 Gy and presumably one order of magnitude more. This dosimeter also permits on-line (in-situ) measurements of the absorbed dose without removing the sensor from the irradiation site. The respective advantages of organic and inorganic dosimeters at these temperature and dose ranges are also discussed. In this connection, we outline new, but negative, results concerning the possible use of silica as a high-temperature, high-dose dosimeter. (author)

  14. Evaluation of personal dose equivalent 'HP(d)' in a external individual monitoring system for X and gamma radiation

    International Nuclear Information System (INIS)

    Santoro, C.; Antonio Filho, J.; Santos, M.A.P.

    2007-01-01

    The good of individual monitoring for external radiation is the assessment of occupational exposure from X and γ radiations in order to assure that the radiological conditions of the workplace are acceptable, safe and satisfactory. The evaluation of radiations doses for workers must not exceed dose limits specified for workers, according to national regulatory agencies. Nowadays, there are two external monitoring systems in use, both based on ICRU definitions. In the conventional system, the workers doses are evaluated in terms of Hx. The personal dosimeter is worn over chest surface and it is calibrated in function of air kerma. In the new system, the workers doses are evaluated in terms of HP(d) and the personal dosimeter is calibrated in function of phantom doses. The aim of this paper is to adapt an external dosimetry laboratory (based on photographic dosimetry) to evaluate the personal dosimeters in terms of HP(d). In this way, a simple methodology, based on linear programming, was utilized. In this adaptation, calibration curves were obtained for radiation qualities (W and N series) described by International Organization for Standardization (ISO 4037-1, 1995). These calibration curves offer a better accuracy on dose determinations and energy below 140 keV, improving the quality of service rendered the society. (author)

  15. A within-subjects trial to test the equivalence of online and paper outcome measures: the Roland Morris Disability Questionnaire

    Directory of Open Access Journals (Sweden)

    Prentice Philippa

    2010-06-01

    Full Text Available Abstract Background Augmenting validated paper versions of existing outcome measures with an equivalent online version may offer substantial research advantages (cost, rapidity and reliability. However, equivalence of online and paper questionnaires cannot be assumed, nor can acceptability to respondents. The aim was to test whether online and written versions of the Roland Morris Disability Questionnaire (RMDQ, a standard measure of functional disability in back pain, are equivalent at both group and individual levels to establish whether they can be used interchangeably. Methods This is a within-participants equivalence study. 167 participants with back pain fully completed both the paper and online versions of the RMDQ in random order. Participants were recruited from a chiropractic clinic and patient support groups in Southern England. Limits of equivalence were pre-defined as 0.5 RMDQ points, the Bland-Altman range was calculated, and participants' comments were examined using content analysis. Results The mean score difference was 0.03 (SD = 1.43, with the 95% Confidence Interval falling entirely within our limits of equivalence (-0.19 to 0.25. The Bland-Altman range was -2.77 to 2.83 RMDQ points. Participants identified unique advantages and disadvantages associated with each version of the RMDQ. Conclusions The group and individual level data suggest that online and paper versions of the RMDQ are equivalent and can be used interchangeably. The Bland-Altman range appears to reflect the known measurement properties of the RMDQ. Furthermore, participants' comments confirmed the potential value to be had from offering them the choice of completing the RMDQ online or on paper.

  16. Radiation dose metrics in CT: assessing dose using the National Quality Forum CT patient safety measure.

    Science.gov (United States)

    Keegan, Jillian; Miglioretti, Diana L; Gould, Robert; Donnelly, Lane F; Wilson, Nicole D; Smith-Bindman, Rebecca

    2014-03-01

    The National Quality Forum (NQF) is a nonprofit consensus organization that recently endorsed a measure focused on CT radiation doses. To comply, facilities must summarize the doses from consecutive scans within age and anatomic area strata and report the data in the medical record. Our purpose was to assess the time needed to assemble the data and to demonstrate how review of such data permits a facility to understand doses. To assemble the data we used for analysis, we used the dose monitoring software eXposure to automatically export dose metrics from consecutive scans in 2010 and 2012. For a subset of 50 exams, we also collected dose metrics manually, copying data directly from the PACS into an excel spreadsheet. Manual data collection for 50 scans required 2 hours and 15 minutes. eXposure compiled the data in under an hour. All dose metrics demonstrated a 30% to 50% reduction between 2010 and 2012. There was also a significant decline and a reduction in the variability of the doses over time. The NQF measure facilitates an institution's capacity to assess the doses they are using for CT as part of routine practice. The necessary data can be collected within a reasonable amount of time either with automatic software or manually. The collection and review of these data will allow facilities to compare their radiation dose distributions with national distributions and allow assessment of temporal trends in the doses they are using. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  17. Out-of-field dose measurements in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kaderka, Robert

    2011-07-13

    This thesis describes the results from measurements of the out-of-field dose in radiotherapy. The dose outside the treatment volume has been determined in a water phantom and an anthropomorphic phantom. Measurements were performed with linac photons, passively delivered protons, scanned protons, passively delivered carbon ions as well as scanned carbon ions. It was found that the use of charged particles for radiotherapy reduces the out-of-field dose by up to three orders of magnitude compared to conventional radiotherapy with photons.

  18. Characteristics of dosemeter types for skin dose measurements in practice

    International Nuclear Information System (INIS)

    Van, D. J.; Bosmans, H.; Marchal, G.; Wambersie, A.

    2005-01-01

    A growing number of papers report deterministic effects in the skin of patients who have undergone interventional radiological procedures. Dose measurements, and especially skin dose measurements, are therefore increasingly important. Methods and acceptable dosemeters are, however, not clearly defined. This paper is the result of a literature overview with regard to assessing the entrance skin dose during radiological examinations by putting a dosemeter on the patient's skin. The relevant intrinsic characteristics, as well as some examples of clinical use of the different detector types, are presented. In this respect, thermoluminescence, scintillation, semiconductor and film dosemeters are discussed and compared with respect to their practical use. (authors)

  19. Combining virtual observatory and equivalent source dipole approaches to describe the geomagnetic field with Swarm measurements

    Science.gov (United States)

    Saturnino, Diana; Langlais, Benoit; Amit, Hagay; Civet, François; Mandea, Mioara; Beucler, Éric

    2018-03-01

    A detailed description of the main geomagnetic field and of its temporal variations (i.e., the secular variation or SV) is crucial to understanding the geodynamo. Although the SV is known with high accuracy at ground magnetic observatory locations, the globally uneven distribution of the observatories hampers the determination of a detailed global pattern of the SV. Over the past two decades, satellites have provided global surveys of the geomagnetic field which have been used to derive global spherical harmonic (SH) models through some strict data selection schemes to minimise external field contributions. However, discrepancies remain between ground measurements and field predictions by these models; indeed the global models do not reproduce small spatial scales of the field temporal variations. To overcome this problem we propose to directly extract time series of the field and its temporal variation from satellite measurements as it is done at observatory locations. We follow a Virtual Observatory (VO) approach and define a global mesh of VOs at satellite altitude. For each VO and each given time interval we apply an Equivalent Source Dipole (ESD) technique to reduce all measurements to a unique location. Synthetic data are first used to validate the new VO-ESD approach. Then, we apply our scheme to data from the first two years of the Swarm mission. For the first time, a 2.5° resolution global mesh of VO time series is built. The VO-ESD derived time series are locally compared to ground observations as well as to satellite-based model predictions. Our approach is able to describe detailed temporal variations of the field at local scales. The VO-ESD time series are then used to derive global spherical harmonic models. For a simple SH parametrization the model describes well the secular trend of the magnetic field both at satellite altitude and at the surface. As more data will be made available, longer VO-ESD time series can be derived and consequently used to

  20. Effects of ionization chamber construction on dose measurements in a heterogeneity

    International Nuclear Information System (INIS)

    Mauceri, T.; Kase, K.

    1987-01-01

    Traditionally, measurements have been made in heterogeneous phantoms to determine the factors which should be applied to dose calculations, when calculating a dose to a heterogeneous medium. Almost all measurements have relied on relatively thin-walled ion chambers, with no attempt to match ion chamber wall material to the measuring medium. The recent AAPM dosimetry protocol has established that a mismatch between ion chamber wall and phantom material can have an effect on dose measurement. To investigate the affect of this mismatch of ion chamber wall material to phantom material, two parallel-plate ion chambers were constructed. One ion chamber from solid water, for measurements in a solid water phantom and the other from plastic lung material, for measurements in a plastic lung material phantom. Correction factors measured by matching ion chamber to media were compared to correction factors measured by using a thin-walled cavity ion chamber with no regard for matching wall and media for cobalt-60, 6-, 10- and 20-MV photon beams. The results demonstrated that the matching of ion chamber to measuring media can be ignored, provided that a small, approximately tissue-equivalent, thin-walled ion chamber is used for measuring the correction factors

  1. Radiation dose measurement of paediatric patients in Estonia

    Energy Technology Data Exchange (ETDEWEB)

    Kepler, K. [Training Centre of Medical Physics and Biomedical Engineering, University of Tartu (Estonia); Lintrop, M. [Department of Radiology, Tartu University Hospital, Tartu (Estonia); Servomaa, A.; Parviainen, T. [STUK - Radiation and Nuclear Safety Authority, Helsinki (Finland); Eek, V.; Filippova, I. [Estonian Radiation Protection Centre, Tallinn (Estonia)

    2003-06-01

    According to the Medical Exposure Directive (97/43/Euratom) the radiation doses to patients should be measured in every hospital and doses should be compared to the reference doses established by the competent authorities. Special attention should be paid to the paediatric x-ray examinations, because the paediatric patients are more radiosensitive than adult patients. The requirement of measurements of radiation dose to patients is not yet included in the Estonian radiation act, but the purpose to join the European Communities makes the quality control in radiology very actual in Estonia. The necessity exists to introduce suitable measurement methods in the Xray departments of Estonian hospitals for establishing feedback system for radiologists, radiographers and medical physicists in optimising the radiation burden of patients and image quality. (orig.)

  2. Imaging and Measuring Electron Beam Dose Distributions Using Holographic Interferometry

    DEFF Research Database (Denmark)

    Miller, Arne; McLaughlin, W. L.

    1975-01-01

    Holographic interferometry was used to image and measure ionizing radiation depth-dose and isodose distributions in transparent liquids. Both broad and narrowly collimated electron beams from accelerators (2–10 MeV) provided short irradiation times of 30 ns to 0.6 s. Holographic images...... and measurements of absorbed dose distributions were achieved in liquids of various densities and thermal properties and in water layers thinner than the electron range and with backings of materials of various densities and atomic numbers. The lowest detectable dose in some liquids was of the order of a few k......Rad. The precision limits of the measurement of dose were found to be ±4%. The procedure was simple and the holographic equipment stable and compact, thus allowing experimentation under routine laboratory conditions and limited space....

  3. Measurement of dose equivalent distribution on-board commercial jet aircraft

    Czech Academy of Sciences Publication Activity Database

    Kubančák, Ján; Ambrožová, Iva; Ploc, Ondřej; Pachnerová Brabcová, Kateřina; Štěpán, Václav; Uchihori, Y.

    2014-01-01

    Roč. 162, č. 3 (2014), s. 215-219 ISSN 0144-8420 Institutional support: RVO:61389005 Keywords : aircrew dosimetry * space weather * CERF Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.913, year: 2014

  4. Measurement of dose equivalent distribution on-board commercial jet-aircraft

    Czech Academy of Sciences Publication Activity Database

    Kubančák, Ján; Ambrožová, Iva; Ploc, Ondřej; Pachnerová Brabcová, Kateřina; Štěpán, Václav; Uchihori, Y.

    -, - (2013) E-ISSN 1742-3406 Grant - others:České vysoké učení technické(CZ) SGS12/200/OHK4/3T/14 Institutional support: RVO:61389005 Keywords : aircrew dosimetry * space weather * CERF Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders

  5. Thermoluminescent dose measurements on board Salyut type orbital stations

    International Nuclear Information System (INIS)

    Akatov, Yu.A.; Arkhangelskij, V.V.; Aleksandrov, A.P.

    1984-06-01

    A small, vibration- and shock-resistant thermoluminescent dosemeter (TLD) system - named PILLE - was developed for orbital stations at the Central Research Institute for Physics, Hungary, to measure the cosmic radiation dose on-board. The first on-board measurements with this system were performed by B. Farkas, the Hungarian astronaut, on the Salyut-6 space station in 1980. The same instrument was used by other crews in the following years. Doses measured at different sites in Salyut-6 are presented. The dose rates varied from 0.7 to 0.11 mGy.day -1 . After the first cosmic measurements, the system was further developed. The minimum detectable dose of the new TLD system is 1 μGy, i.e. less by one order of magnitude than that of the former system. The self-irradiation dose rate of the TLD bulbs is also reduced by more than an order of magnitude to 10 nGy.h -1 , by use of potassium-free glass for the bulb envelope. This new type of PILLE TLD system is currently on-board Salyut-7. The dose rates (0.12-0.23 mGy.day -1 ) measured in 1983 are presented in detail. (author)

  6. INREM II: a computer implementation of recent models for estimating the dose equivalent to organs of man from an inhaled or ingested radionuclide

    International Nuclear Information System (INIS)

    Killough, G.G.; Dunning, D.E. Jr.; Pleasant, J.C.

    1978-01-01

    This report describes a computer code, INREM II, which calculates the internal radiation dose equivalent to organs of man which results from the intake of a radionuclide by inhalation or ingestion. Deposition and removal of radioactivity from the respiratory tract is represented by the ICRP Task Group Lung Model. A four-segment catenary model of the GI tract is used to estimate movement of radioactive material that is ingested or swallowed after being cleared from the respiratory tract. Retention of radioactivity in other organs is specified by linear combinations of decaying exponential functions. The formation and decay of radioactive daughters is treated explicitly, with each radionuclide species in the chain having its own uptake and retention parameters, as supplied by the user. The dose equivalent to a target organ is computed as the sum of contributions from each source organ in which radioactivity is assumed to be situated. This calculation utilizes a matrix of S-factors (rem/μCi-day) supplied by the user for the particular choice of source and target organs. Output permits the evaluation of crossfire components of dose when penetrating radiations are present. INREM II is coded in FORTRAN IV and has been compiled and executed on an IBM-360 computer

  7. Measuring radiation dose to patients undergoing fluoroscopically-guided interventions

    International Nuclear Information System (INIS)

    Lubis, L E; Badawy, M K

    2016-01-01

    The increasing prevalence and complexity of fluoroscopically guided interventions (FGI) raises concern regarding radiation dose to patients subjected to the procedure. Despite current evidence showing the risk to patients from the deterministic effects of radiation (e.g. skin burns), radiation induced injuries remain commonplace. This review aims to increase the awareness surrounding radiation dose measurement for patients undergoing FGI. A review of the literature was conducted alongside previous researches from the authors’ department. Studies pertaining to patient dose measurement, its formalism along with current advances and present challenges were reviewed. Current patient monitoring techniques (using available radiation dosimeters), as well as the inadequacy of accepting displayed dose as patient radiation dose is discussed. Furthermore, advances in real-time patient radiation dose estimation during FGI are considered. Patient dosimetry in FGI, particularly in real time, remains an ongoing challenge. The increasing occurrence and sophistication of these procedures calls for further advances in the field of patient radiation dose monitoring. Improved measuring techniques will aid clinicians in better predicting and managing radiation induced injury following FGI, thus improving patient care. (paper)

  8. Mapping of isoexposure curves for evaluation of equivalent environmental doses for radiodiagnostic mobile equipment; Mapeamento de curvas de isoexposicao para avaliacao de equivalente de dose ambiente para equipamentos moveis de radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Bacelar, Alexandre, E-mail: abacelar@hcpa.ufrgs.b [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Hospital de Clinicas. Setor de Fisica Medica e Radioprotecao; Andrade, Jose Rodrigo Mendes, E-mail: jose.andrade@santacasa.tche.b [Irmandade da Santa Casa de Misericordia de Porto Alegre, RS (Brazil). Servico de Atencao a Saude e Qualidade de Vida; Fischer, Andreia Caroline Fischer da Silveira; Accurso, Andre; Hoff, Gabriela, E-mail: andreia.silveira.001@acad.pucrs.b, E-mail: andre.accurso@acad.pucrs.b [Pontificia Univ. Catolica do Rio Grande do Sul (PUC/RS), Porto Alegre, RS (Brazil). Grupo de Experimentacao e Simulacao Computacional em Fisica Medica

    2011-10-26

    This paper generates iso exposure curves in areas where the mobile radiodiagnostic equipment are used for evaluation of iso kerma map and the environment equivalent dose (H{sup *}(d)). It was used a Shimadzu mobile equipment and two Siemens, with non anthropomorphic scatter. The exposure was measured in a mesh of 4.20 x 4.20 square meter in steps of 30 cm, at half height from the scatterer. The calculation of H{sup *}(d) were estimated for a worker present in all the procedures in a period of 11 months, being considered 3.55 m As/examination and 44.5 procedures/month (adult UTI) and 3.16 m As/examination and 20.1 procedure/month (pediatric UTI), and 3.16 m As/examination and 20.1 procedure/month (pediatric UTI). It was observed that there exist points where the H{sup *}(d) was over the limit established for the free area inside the radius of 30 cm from the central beam of radiation in the case of pediatric UTI and 60 cm for adult UTI. The points localized 2.1 m from the center presented values lower than 25% of those limit

  9. Measurement of spatial dose distribution for evaluation operator dose during nero-interventional procedures

    Energy Technology Data Exchange (ETDEWEB)

    Han, Su Chul [Division of Medical Radiation Equipment, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Hong, Dong Hee [Dept. of Radiology Science, Far East University, Eumseong (Korea, Republic of)

    2016-09-15

    The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in 18.1±10.5%, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.

  10. Angular and energy dependence of radiation protection monitors to the quantity ambient dose equivalent for gamma radiation;Dependencia angular e energetica de monitores de radioprotecao para medidas de equivalente de dose ambiental para radiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Nonato, Fernanda B.C.; Carvalho, Valdir S.; Diniz, Raphael E.; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    In Brazil, most of the equipment used for monitoring area is just used in the quantities exposure and absorbed dose, with the need of adjustment to the ambient dose equivalent, H{sup *}(10). In this work, 19 Geiger-Mueller detectors and 7 ionization chambers were calibrated in the Calibration Laboratory of the Instituto de Pesquisas Energeticas Nucleares, IPEN. The energy dependence of these radiation detectors was studied for gamma radiation ({sup 137}Cs e {sup 60}Co) and the angular dependence, for {sup 137}Cs radiation. (author)

  11. A new neutron dose equivalent rate meter with improved neutron energy response in terms of H*(10)

    International Nuclear Information System (INIS)

    Klett, A.; Maushart, R.; Burgkhardt, B.; Fieg, G.; Piesch, E.

    1994-01-01

    Conventional neutron dose rate meters make use of thermal neutron detectors such as 3 He counters located in the center of a moderator and absorber for thermal neutrons. The various commercial types used up to now have the disadvantage that the reading is extremely energy dependent exceeding a factor of up to 15. The need to improve the energy response and the sensitivity in the lower dose rate range resulted in joint cooperation between KfK and EG7G Berthold. On the basis of Monte-Carlo calculations and comprehensive calibrations with monoenergetic neutrons at the PTB Braunshweig, a new type of rem-counter has been optimized using a 10 cm x 4 cm diameter 3 He-counter. Both calculations and experiments resulted in a lower energy dependence within ±40% in the energy range 20 keV to 19 MeV. The commercially available dose rate meter of 25 cm diameter, with a weight below 10 kg and with a high neutron sensitivity of 3 counts per nSv has a dose rate range of 0.1 μSv/h - 100 mSv/h and low γ-sensitivity. With integrated electronics, this instrument is applicable for routine monitoring as well as for stationary monitoring of radiation fields near accelerators

  12. Different concentrations and volumes of p-phenylenediamine in pet. (equivalent doses) are associated with similar patch test outcomes

    DEFF Research Database (Denmark)

    Andersen, Flemming; Hamann, Carsten R; Andersen, Klaus E

    2018-01-01

    BACKGROUND: Concern about causing active sensitization when patch testing is performed with p-phenylenediamine (PPD) 1% pet. has led to a recommendation to use PPD 0.3% pet. as a potentially safer preparation. However, the dose per area of allergen delivered, and hence the risk of active sensitiz...

  13. The cross-cultural equivalence of parental rearing measure : EAABU-C

    NARCIS (Netherlands)

    Dekovic, M; ten Have, M; Vollebergh, WAM; Pels, T; Oosterwegel, A; Wissink, IB; De Winter, AF; Verhulst, FC; Ormel, J

    2006-01-01

    We examined the cross-cultural equivalence of a widely used instrument that assesses perceived parental rearing, the EMBU-C, among native Dutch and immigrant adolescents living in The Netherlands. The results of a multigroup confirmatory factor analysis indicated that the factor structure of the

  14. Correlation of dose rate and spectral measurements in the Inner Van Allen Belt.

    Science.gov (United States)

    Thede, A L; Radke, G E

    1968-01-01

    Dose rate measurements and the charged particle environment of the Inner Van Allen Belt have been correlated using recent data obtained from the radiation research satellite, OV3-4. Six tissue equivalent ionization chambers, constructed of a material which simulates the muscle tissue response to ionizing radiation, measured the dose rate behind various types and thicknesses of material. The specific shields used for several of the chambers were 0.192 g/cm2 aluminum, 0.797 g/cm2 Lucite and 4.485 g/cm2 brass. The proton and electron spectra were determined with an omnidirectional spectrometer using solid state detectors. The spectral measurements discussed here include geomagnetically trapped protons with energies in the range of 15 to 200 MeV. The proton spectra and dose rates are presented as profiles in terms of the McIlwain parameters of L (1.5, 2.0 and 2.5 earth radii) and the magnetic field B (0.050 to 0.250 gauss). The excellent agreement between the measured dose rate and the theoretically predicted dose rate based on the measured spectra provides justification for the radiation transport techniques now being employed to predict the doses to be encountered during future manned space missions. It was found, however, that a more adequate description of the proton fluxes for energies greater than 50 MeV will be necessary to predict dose rate accurately behind shields of 2.5 g/cm2 thickness or greater.

  15. Testing the measurement equivalence of paper and interactive voice response system versions of the EORTC QLQ-C30

    NARCIS (Netherlands)

    Lundy, J.J.; Coons, S.J.; Aaronson, N.K.

    2014-01-01

    Purpose: The objective of this study was to evaluate the measurement equivalence of an interactive voice response system (IVRS) version and the original paper-based version of the EORTC QLQ-C30. Methods: The QLQ-C30 is a cancer-specific, health-related quality of life questionnaire consisting of

  16. Diamond detector in absorbed dose measurements in high-energy linear accelerator photon and electron beams.

    Science.gov (United States)

    Ravichandran, Ramamoorthy; Binukumar, John Pichy; Al Amri, Iqbal; Davis, Cheriyathmanjiyil Antony

    2016-03-08

    Diamond detectors (DD) are preferred in small field dosimetry of radiation beams because of small dose profile penumbras, better spatial resolution, and tissue-equivalent properties. We investigated a commercially available 'microdiamond' detector in realizing absorbed dose from first principles. A microdiamond detector, type TM 60019 with tandem electrometer is used to measure absorbed doses in water, nylon, and PMMA phantoms. With sensitive volume 0.004 mm3, radius 1.1mm, thickness 1 x10(-3) mm, the nominal response is 1 nC/Gy. It is assumed that the diamond detector could collect total electric charge (nC) developed during irradiation at 0 V bias. We found that dose rate effect is less than 0.7% for changing dose rate by 500 MU/min. The reproducibility in obtaining readings with diamond detector is found to be ± 0.17% (1 SD) (n = 11). The measured absorbed doses for 6 MV and 15 MV photons arrived at using mass energy absorption coefficients and stop-ping power ratios compared well with Nd, water calibrated ion chamber measured absorbed doses within 3% in water, PMMA, and nylon media. The calibration factor obtained for diamond detector confirmed response variation is due to sensitivity due to difference in manufacturing process. For electron beams, we had to apply ratio of electron densities of water to carbon. Our results qualify diamond dosimeter as a transfer standard, based on long-term stability and reproducibility. Based on micro-dimensions, we recommend these detectors for pretreatment dose verifications in small field irradiations like stereotactic treatments with image guidance.

  17. Measurement of Skin Dose from Using the Treatment Immobilization Devices

    International Nuclear Information System (INIS)

    Je, Jae Yong; Park, Chul Woo; Noh, Kyung Suk

    2009-01-01

    The research was about the relation between the dorsal side dose measured by using the phantom body (Alderson Rando Phantom) and factors like contacted material of the patients, the size of the field, angle of incidence. Compared with mylar (tennis racket), the dose on 10 x 10 cm 2 field size of cotton was increased by 2% and by 8% in the case of breast board. In the case of 15 x 15 cm 2 field size, the dose was increased by 6% compared with 10 x 10 cm 2 size. The field size of 20 x 20 cm 2 resulted in 10% increase of dose, while 5 x 5 cm 2 produced 13% decrease. Compared with incident angle 0 degree, the cases for the incident angle 5 degrees had 0.4% less dose for breast board, 0.5% for tennis racket, 1.1% for cotton. The cases for the incident angle 10 degrees had 1.5% less dose for breast board, 1.9% for tennis racket, 2.6% for cotton. For the incident angle 15 degrees, breast board, tennis racket, cotton caused decrease of dose by 3.9%, 2.6%, 3.86% respectively. Resultantly carbon material can cause more skin dose in treatment field. By the results of this study, we recommend that one should avoid the contact between the carbon material and skin.

  18. Retrieval of Effective Correlation Length and Snow Water Equivalent from Radar and Passive Microwave Measurements

    Directory of Open Access Journals (Sweden)

    Juha Lemmetyinen

    2018-01-01

    Full Text Available Current methods for retrieving SWE (snow water equivalent from space rely on passive microwave sensors. Observations are limited by poor spatial resolution, ambiguities related to separation of snow microstructural properties from the total snow mass, and signal saturation when snow is deep (~>80 cm. The use of SAR (Synthetic Aperture Radar at suitable frequencies has been suggested as a potential observation method to overcome the coarse resolution of passive microwave sensors. Nevertheless, suitable sensors operating from space are, up to now, unavailable. Active microwave retrievals suffer, however, from the same difficulties as the passive case in separating impacts of scattering efficiency from those of snow mass. In this study, we explore the potential of applying active (radar and passive (radiometer microwave observations in tandem, by using a dataset of co-incident tower-based active and passive microwave observations and detailed in situ data from a test site in Northern Finland. The dataset spans four winter seasons with daily coverage. In order to quantify the temporal variability of snow microstructure, we derive an effective correlation length for the snowpack (treated as a single layer, which matches the simulated microwave response of a semi-empirical radiative transfer model to observations. This effective parameter is derived from radiometer and radar observations at different frequencies and frequency combinations (10.2, 13.3 and 16.7 GHz for radar; 10.65, 18.7 and 37 GHz for radiometer. Under dry snow conditions, correlations are found between the effective correlation length retrieved from active and passive measurements. Consequently, the derived effective correlation length from passive microwave observations is applied to parameterize the retrieval of SWE using radar, improving retrieval skill compared to a case with no prior knowledge of snow-scattering efficiency. The same concept can be applied to future radar

  19. The antiproton depth–dose curve measured with alanine detectors

    CERN Document Server

    Bassler, Niels; Palmans, Hugo; Holzscheiter, Michael H; Kovacevic, Sandra

    2008-01-01

    n this paper we report on the measurement of the antiproton depth–dose curve, with alanine detectors. The results are compared with simulations using the particle energy spectrum calculated by FLUKA, and using the track structure model of Hansen and Olsen for conversion of calculated dose into response. A good agreement is observed between the measured and calculated relative effectiveness although an underestimation of the measured values beyond the Bragg-peak remains unexplained. The model prediction of response of alanine towards heavy charged particles encourages future use of the alanine detectors for dosimetry of mixed radiation fields.

  20. The MapCHECK Measurement Uncertainty function and its effect on planar dose pass rates.

    Science.gov (United States)

    Bailey, Daniel W; Spaans, Jason D; Kumaraswamy, Lalith K; Podgorsak, Matthew B

    2016-03-08

    Our study aimed to quantify the effect of the Measurement Uncertainty function on planar dosimetry pass rates, as measured and analyzed with the Sun Nuclear Corporation MapCHECK 2 array and its associated software. This optional function is toggled in the program preferences of the software (though turned on by default upon installation), and automatically increases the dose difference tolerance defined by the user for each planar dose comparison. Dose planes from 109 static-gantry IMRT fields and 40 VMAT arcs, of varying modulation complexity, were measured at 5 cm water-equivalent depth in the MapCHECK 2 diode array, and respective calculated dose planes were exported from a commercial treatment planning system. Planar dose comparison pass rates were calculated within the Sun Nuclear Corporation analytic software using a number of calculation parameters, including Measurement Uncertainty on and off. By varying the percent difference (%Diff) criterion for similar analyses performed with Measurement Uncertainty turned off, an effective %Diff criterion was defined for each field/arc corresponding to the pass rate achieved with Measurement Uncertainty turned on. On average, the Measurement Uncertainty function increases the user-defined %Diff criterion by 0.8%-1.1% for 3%/3 mm analysis, depending on plan type and calculation technique (corresponding to an average change in pass rate of 1.0%-3.5%, and a maximum change of 8.7%). At the 2%/2 mm level, the Measurement Uncertainty function increases the user-defined %Diff criterion by 0.7%-1.2% on average, again depending on plan type and calculation technique (corresponding to an average change in pass rate of 3.5%-8.1%, and a maximum change of 14.2%). The largest increases in pass rate due to the Measurement Uncertainty function are generally seen with poorly matched planar dose comparisons, while the function has a notably smaller effect as pass rates approach 100%. The Measurement Uncertainty function, then, may

  1. Determination of the equivalent doses due to the ingestion of radionuclides from the uranium and thorium series presents in drinking waters of the region of Santa Luzia, Paraiba state, Brazil; Determinacao das doses equivalentes devido a ingestao de radionuclideos das series do uranio e torio presentes em aguas de consumo do municipio de Santa Luzia, estado da Paraiba

    Energy Technology Data Exchange (ETDEWEB)

    Pastura, Valeria F. da S., E-mail: vpastura@cnen.gov.b [Comissao Nacional de Energia Nuclear (DRSN/CNEN), Rio de Janeiro, RJ (Brazil). Diretoria de Radioprotecao e Seguranca Nuclear. Coordenacao de Materias Primas e Minerais; Campos, Thomas F. da C.; Petta, Reinaldo A., E-mail: thomascampos@geologia.ufrn.b, E-mail: petta@geologia.ufrn.b [Universidade Federal do Rio Grande do Norte (LARANA/UFRN), Natal, RN (Brazil). Lab. de Radioatividade Natural

    2011-10-26

    This paper determined the original dose equivalents from radionuclides of uranium and thorium series in a drinking water of well which is supplied to the population of Santa Luzia, Paraiba state, Brazil. The collected waters are near to the mineralized phlegmatic bodies in rose quartz and amazonite feldspar. Radiometric measurements performed on the feldspar vein point out counting ratios surrounding 30000 cps and the analysis of collected samples of minerals presented tenors for the {sup 226}Ra and {sup 219}Pb varying from 0.50 to 2.30 Bq/sw. For determination of concentration of radionuclides U{sub Total}, {sup 226}Ra, {sup 228}Ra and {sup 219}Pb, found in the not desalinated, two methods were used, spectrophotometry with arsenazo and radiochemistry, both realized in the CNEN-LAPOC laboratories. For the calculation of dose equivalent it was taken into consideration the following parameters: the dose coefficients for incorporation by ingestion for public individuals with ages over 17 years (Norma CNEN-NN-3.01, Regulatory Position 3.01/011) and daily ingestion of 4 liters of water, which is over the recommended by the WHO of 2L/day - 1993. The obtained values were compared with the reference value for compromised dose equivalent established by WHO for evaluate the risk potential to the health of population, by ingestion. The radionuclide concentrations in the wells varies from 0.054 to 0.21 Bq/L, resulting dose equivalents of 3.94 x 10{sup -3} mSv/year and 0.17 mSv/year in the studied population

  2. The equivalent circuit of single crab muscle fibers as determined by impedance measurements with intracellular electrodes.

    Science.gov (United States)

    Eisenberg, R S

    1967-07-01

    The input impedance of muscle fibers of the crab was determined with microelectrodes over the frequency range 1 cps to 10 kc/sec. Care was taken to analyze, reduce, and correct for capacitive artifact. One dimensional cable theory was used to determine the properties of the equivalent circuit of the membrane admittance, and the errors introduced by the neglect of the three dimensional spread of current are discussed. In seven fibers the equivalent circuit of an element of the membrane admittance must contain a DC path and two capacitances, each in series with a resistance. In two fibers, the element of membrane admittance could be described by one capacitance in parallel with a resistance. In several fibers there was evidence for a third very large capacitance. The values of the elements of the equivalent circuit depend on which of several equivalent circuits is chosen. The circuit (with a minimum number of elements) that was considered most reasonably consistent with the anatomy of the fiber has two branches in parallel: one branch having a resistance R(e) in series with a capacitance C(e); the other branch having a resistance R(b) in series with a parallel combination of a resistance R(m) and a capacitance C(m). The average circuit values (seven fibers) for this model, treating the fiber as a cylinder of sarcolemma without infoldings or tubular invaginations, are R(e) = 21 ohm cm(2); C(e) = 47 microf/cm(2); R(b) = 10.2 ohm cm(2); R(m) = 173 ohm cm(2); C(m) = 9.0 microf/cm(2). The relation of this equivalent circuit and another with a nonminimum number of circuit elements to the fine structure of crab muscle is discussed. In the above equivalent circuit R(m) and C(m) are attributed to the sarcolemma; R(e) and C(e), to the sarcotubular system; and R(b), to the amorphous material found around crab fibers. Estimates of actual surface area of the sarcolemma and sarcotubular system permit the average circuit values to be expressed in terms of unit membrane area. The

  3. Neutron and gamma dose measurement in the working area of a research reactor using passive dosimeters

    International Nuclear Information System (INIS)

    Sathian, Deepa; Bakshi, A.K.; Prasad, Sajin; Kalyanasundaram, N.; Chougaonkar, M.P.

    2012-01-01

    A national facility (research reactor) for neutron beam research is operated for use of neutron in condensed matter physics research. This facility has a number of neutron beam holes around it to carry out neutron scattering experiment by scientists/researchers from universities and research institutions. The researcher has to spend long duration around the experimental facilities to record and analyze the experimental data. In the present study, radiation dose measurement of several such locations around the experimental facilities of a research reactor was carried out where there is a likelihood of occupancy. Considering the occupancy of the locations which is either rare or occasional, the measured dose equivalent rates are considered to be well within the stipulated limit as per the guidelines of Atomic Energy Regulatory Board (the regulatory authority of India) for radiation workers

  4. Cosmic-ray contribution in measurement of environmental gamma-ray dose

    International Nuclear Information System (INIS)

    Nagaoka, Kazunori; Honda, Kouichirou; Miyano, Keiji

    1996-01-01

    Nowadays several kinds of dosimeters are being used for environmental gamma-ray monitoring. However the results measured by those instruments are not always in good agreement. It may be caused from the different characteristics of dosimeters. In particular the different responses of the instruments to cosmic-rays give significant influence on the results. Environmental radiation measurements at various altitudes on Mt. Fuji were carried out using a scintillation spectrometer with 3''φ spherical NaI(Tl), a pressurized ionization chamber (PIC), an air-equivalent ionization chamber (IC), thermoluminescence dosimeters (TLD), radiophotoluminescence glass dosimeters (RPLD) and NaI(Tl) scintillation survey meters so that the response characteristics of these instruments to cosmic-rays could be clarified. Cosmic-ray contributions for all instruments were correlated with counting rate over 3 MeV by the spectrometer. Each contribution can be estimated by measurement of the counting rate. Conversion factors (nGy/h/cpm) for IC, PIC, TLD, RPLD and NaI survey meters (TCS166 and TCS121C) were 0.33, 0.32, 0.25, 0.24, 0.06 and -0.01, respectively. Self-doses of these instruments were estimated by measurements at Nokogiriyama facilities of the Institute for Cosmic Ray Research, University of Tokyo. Self-doses for TLD and RPLD were approximately 6 nGy/h. The self dose effect should be taken into consideration in environmental dose measurements. These data are expected to be useful in estimating the cosmic-ray contribution and self-dose in the measurement of environmental gamma-ray dose. (author)

  5. Neutron dose measurements with the GSI ball at high energy accelerators

    International Nuclear Information System (INIS)

    Fehrenbacher, G.; Gutermuth, F.; Radon, T.; Kozlova, E.

    2005-01-01

    Full text: At high energy particle accelerators the production of neutron radiation dominates radiation protection. For the radiation survey at accelerators there is a need for reliable detection systems (passive radiation monitors), which can measure the dose for a wide range of neutron energies independently on the beam pulse structure of the produced radiation. In this work a passive neutron dosemeter for the measurement of the ambient dose equivalent is presented. The dosemeter is suitable for measurements of the emerging neutron radiation at accelerators for the whole energy range up to about 10 GeV. The dosemeter consists of a polyethylene sphere, TL elements (pairs of TLD600/700) and an additional lead layer (PE/Pb) in neutron fields at high energy accelerators is investigated in this work. Results of dose measurements which were performed in realistic neutron fields at the high energy accelerator SPS at CERN (CERF facility) and in Cave A at the heavy ion synchrotron SIS at GSI are presented. The results of these measurements are compared with the expected dose values from the neutron spectra determined for the measurement positions at CERF and in Cave A (FLUKA) and with the dosemeter response derived by the calculated response functions (FLUKA) folded with the neutron spectra. The comparisons show that the additional lead layer in the PE/Pb-sphere improves significantly the response of the dosemeter. The response of the PE/Pb-sphere is 40 to 50 % higher at CERF and Cave A in comparison to the bare PE-sphere. At CERF the dose values of the PE/Pb-sphere is about 25 % lower than the expected dose value, whilst for Cave A, a rather good agreement was found (2 % deviation). (author)

  6. Measurements and applications of dose indices in radiography

    International Nuclear Information System (INIS)

    Chen, T.R.; Tyan, Y.S.; Yang, J.J.; Shao, C.H.; Lin, J.Y.; Tung, C.J.

    2011-01-01

    Assessments of radiation dose and image quality are required in diagnostic radiography for quality assurance and optimization studies. In work currently being undertaken, dose indices were measured and image quality evaluated for a chest PA procedure. Thermoluminescent dosimeters of the GR-200 type were attached to the entrance and exit surfaces and placed at various depths of the PMMA phantom to measure the entrance surface dose, the exit surface dose, and the organ dose index. The effective dose was estimated from the entrance surface dose using PCXMC software. Two contrast-detail image plates, one with air holes for the low contrast objects and the other with gypsum holes for the high contrast objects, were used to obtain radiographic images. This image plate was placed at different depths from the entrance surface of the phantom to simulate objects at different positions in the body. Each image was evaluated by three independent radiologists to determine image quality. Analyses of radiation dose versus image quality were performed to determine the optimal technical factors such as, filtration and tube potential. It was found that an 11-cm thick PMMA phantom best simulated the patients. The fractional dose backscattered from this phantom was between 22% and 27% for kVp’s between 66 and 133. Optimization analyses showed that no extra filter was required. For low contrast objects, an optimal choice of tube potential was 120 kVp. For high contrast objects, a kVp as low as 77 kVp could be used, depending on the image quality requirement.

  7. Measurements of dose distribution in thyroids, gonads, crystalline and other organs, for radio-diagnostics with computorized tomography

    International Nuclear Information System (INIS)

    Coelho, M.J.

    1983-01-01

    An evaluation of radiation doses in organs, from radiologic examinations by computorized tomography was done, comparing with theoretic data obtained by Monte Carlo method. The measurements were done with help of a 'Rando Alderson Phantom' exposed to irradiation coming from a 0450 AS and E Pfizer Tomographic. The cases under study were the head and abdomen examinations. The dose assessment was done by using mini TLD's of LiF. The calculated dose equivalents were obtained by using the Monte Carlo method applied to a mathematical antropomorphic phantom, simulating the same experimental arrangements. The results were compared with the experimental one. (E.G.) [pt

  8. Noise equivalent count measurements in a neuro-PET scanner with retractable septa

    International Nuclear Information System (INIS)

    Bailey, D.L.; Jones, T.; Spinks, T.J.; Gilardi, M.C.; Townsend, D.W.

    1990-01-01

    This paper reports on the removal of interplane septa in a PET scanner that enables acquisition of all possible lines of response (3D mode) in an effort to maximize the available number of detected events. One problem with this method at high countrates, however, is a markedly increased deadtime and randoms rate, which has a deleterious effect on data quality. The noise-equivalent countrate (NEC) performance of a neuro-PET scanner has been determined with and without interplane septa on uniform cylindrical phantoms of differing radii and in human studies to assess the optimum countrate conditions that realize the maximum gain. In the brain, the effective gain in NEC performance for 3D ranges from >5 at low countrates to ∼3.3 at 200 kcps (equivalent to 37 kcps in 2D). The gains of the 3D method assessed by this analysis are significant, and are shown to be highly dependent on countrate and object dimensions

  9. A new look at CT dose measurement: Beyond CTDI

    International Nuclear Information System (INIS)

    Dixon, Robert L.

    2003-01-01

    Equations are derived for generating accumulated dose distributions and the dose line integral in a cylindrical dosimetry phantom for a helical CT scan series from the single slice dose profiles using convolution methods. This exposition will better clarify the nature of the dose distribution in helical CT, as well as providing the medical physicist with a better understanding of the physics involved in dose delivery and the measurement process. Also addressed is the concern that as radiation beam widths for multi-slice scanners get wider, the current methodology based on the measurement of the integral of the single slice profile using a 10 cm long ion chamber (CTDI 100 ) may no longer be adequate. It is shown that this measurement would underestimate the equilibrium dose and dose line integral by about 20% in the center of the body phantom, and by about 10% in the center of the head phantom for a 20 mm nominal beam width in a multi-slice scanner. Rather than making the ion chamber even longer to collect the broad scatter tails of the single slice profile, an alternative to the CTDI method is suggested which involves using a small volume ion chamber, and scanning a length of phantom long enough to establish dose equilibrium at the location of the chamber. With a modern CT scanner, such a scan length can be covered in 15 s or less with a helical or axial series, so this method is not significantly more time-consuming than the long chamber method. The method is demonstrated experimentally herein

  10. Radiochromic Plastic Films for Accurate Measurement of Radiation Absorbed Dose and Dose Distributions

    DEFF Research Database (Denmark)

    McLaughlin, W. L.; Miller, Arne; Fidan, S.

    1977-01-01

    of many polymeric systems in industrial radiation processing. The result is that errors due to energy dependence of response of the radiation sensor are effectively reduced, since the spectral sensitivity of the dose meter matches that of the polymer of interest, over a wide range of photon and electron......Thin radiochromic dye films are useful for measuring large radiation absorbed doses (105–108 rads) and for high-resolution imaging of dose patterns produced by penetrating radiation beams passing through non-homogeneous media. Certain types of amino-substituted triarylmethane cyanides dissolved...... in polymeric solutions can be cast into flexible free-standing thin films of uniform thickness and reproducible response to ultraviolet and ionizing radiation. The increase in optical density versus energy deposited by radiation is linear over a wide range of doses and is for practical purposes independent...

  11. Dynamic Equivalent Modeling of a Grid-Tied Microgrid Based on Characteristic Model and Measurement Data

    Directory of Open Access Journals (Sweden)

    Changchun Cai

    2017-11-01

    Full Text Available Microgrids can significantly improve the utilization of distributed generation (DG and the reliability of the power supply. However, in the grid-tied operational mode, the interaction between the microgrid and the distribution network cannot be ignored. The paper proposes an equivalent modeling method for the microgrid under grid-tied mode based on a characteristic model. It can simplify the microgrid model in the numerical simulation of the distribution network. The proposed equivalent model can present the dynamic response of a microgrid but not miss any of its primary characteristics. The characteristic model is represented by a low-order time-varying differential equation with the same characteristics of the original microgrid system. During the modeling process, the voltage and the power exchanged between the microgrid and distribution network are collected as the training data for the identification of model parameters. A recursive damped least squares algorithm (RDLS is used for the parameter identification. A microgrid system containing different DGs is built to test the proposed modeling method in DIgSILENT, and the results show that the proposed dynamic equivalent modeling method is effective and the characteristic model can present the dynamic behaviors of the detailed model of a microgrid.

  12. SU-F-T-426: Measurement of Dose Enhancement Due to Backscatter From Modern Dental Materials

    Energy Technology Data Exchange (ETDEWEB)

    Hurwitz, M; Margalit, D; Williams, C [Brigham and Women’s Hospital / Harvard Medical School, Boston, MA (United States); Tso, T; Lee, S; Rosen, E [Harvard School of Dental Medicine, Boston, MA (United States)

    2016-06-15

    Purpose: High-density materials used in dental restoration can cause significant localized dose enhancement due to electron backscatter in head-and-neck radiotherapy, increasing the risk of mucositis. The materials used in prosthetic dentistry have evolved in the last decades from metal alloys to ceramics. We aim to determine the dose enhancement caused by backscatter from currently-used dental materials. Methods: Measurements were performed for three different dental materials: lithium disilicate (Li{sub 2}Si{sub 2}O{sub 5}), zirconium dioxide (ZrO{sub 2}), and gold alloy. Small thin squares (2×2×0.15 cm{sup 3}) of the material were fabricated, and placed into a phantom composed of tissue-equivalent material. The phantom was irradiated with a single 6 MV photon field. A thin-window parallel-plate ion chamber was used to measure the dose at varying distances from the proximal interface between the material and the plastic. Results: The dose enhancement at the interface between the high-density and tissue-equivalent materials, relative to a homogeneous phantom, was 54% for the gold alloy, 31% for ZrO{sub 2}, and 9% for Li{sub 2}Si{sub 2}O{sub 5}. This enhancement decreased rapidly with distance from the interface, falling to 11%, 5%, and 0.5%, respectively, 2 mm from the interface. Comparisons with the modeling of this effect in treatment planning systems are performed. Conclusion: While dose enhancement due to dental restoration is smaller with ceramic materials than with metal alloys, it can still be significant. A spacer of about 2–3 mm would be effective in reducing this enhancement, even for metal alloys.

  13. Assessments of conversion coefficients between equivalent dose and accumulated activity using pre-dose scanning images of patients subjected to radioiodine treatment and the Fax/Egs4 computational model

    International Nuclear Information System (INIS)

    Lopes Filho, Ferdinand de J.; Vieira, Jose W.; Andrade Lima, Fernando R. de

    2008-01-01

    The radioiodine is a technique for treatment of thyroid cancer. In this technique, the patients are submitted to the incorporation of the radioactive substance sodium iodide (Na 131 I), which reacts with physiologically metastasis, thyroid tissue remains of and other organs and tissues of the human body. The locations of these reactions are known as areas of highest concentration, hipercaptured areas, hiperconcentrator areas, 'hot areas' or organ-sources and are viewed through images of nuclear medicine scan known as pre-dose (front and rear). To obtain these images, the patient receives, orally, a quantity of 131 I with low activity (± 74 MBq) and is positioned in the chamber of flicker. According to the attendance of hot areas shown in the images, the doctor determines the nuclear activity to be administered in treatment. This analysis is purely qualitative. In this study, the scanning images of pre-dose were adjusted to the dimensions of FAX voxel phantom, and the hot areas correspond to internal sources of the proposed model. Algorithms were developed to generate particles (photons and electrons) in these regions of the FAX. To estimate the coefficients of conversions between equivalent dose and accumulated activity in major radiosensitive organs, FAX and algorithms source were coupled to the Monte Carlo EGS4 code (Electron Gamma Shower, version 4). With these factors is possible to estimate the equivalent doses in the radiosensitive organs and tissues of patients as long as is know the activity administered and the half-life of organic sources. (author)

  14. NOTE: Surface dose extrapolation measurements with radiographic film

    Science.gov (United States)

    Butson, Martin J.; Cheung, Tsang; Yu, Peter K. N.; Currie, Michael

    2004-07-01

    Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown that the surface percentage dose can be estimated within ±3% of parallel plate ionization chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10 cm, 20 cm and 30 cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. The corresponding parallel plate ionization chamber measurements are 16%, 27% and 37%, respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size.

  15. Development and use of a fifteen year-old equivalent mathematical phantom for internal dose calculations. [Radiation dose distributions from /sup 99m/Tc-labeled compounds

    Energy Technology Data Exchange (ETDEWEB)

    Jones, R.M.; Poston, J.W.; Hwang, J.L.; Jones, T.D.; Warner, G.G.

    1976-06-01

    The existence of a phantom based on anatomical data for the average fifteen-year-old provides for a proficient means of obtaining estimates of absorbed dose for children of that age. Dimensions representative of an average fifteen-year-old human, obtained from various biological and medical research, were transformed into a mathematical construct of idealized shapes of the exterior, skeletal system, and internal organs of a human. The idealization for an average adult presently in use by the International Commission on Radiological Protection was used as a basis for design. The mathematical equations describing the phantom were developed to be readily adaptable to present-day methods of dose estimation. Typical exposure situations in nuclear medicine have previously been modeled for existing phantoms. With no further development of the exposure model necessary, adaptation to the fifteen-year-old phantom demonstrated the utility of the design. Estimates of absorbed dose were obtained for the administration of two radiopharmaceuticals, /sup 99m/Tc-sulfur colloid and /sup 99m/Tc-DMSA. (auth)

  16. Accredited dose measurements for validation of radiation sterilized products

    DEFF Research Database (Denmark)

    Miller, A.

    1993-01-01

    for control of radiation sterilization. The accredited services include: 1. 1. Irradiation of dosimeters and test samples with cobalt-60 gamma rays. 2. 2. Irradiation of dosimeters and test samples with 10 MeV electrons. 3. 3. Issue of and measurement with calibrated dosimeters. 4. 4. Measurement...... of the dosimetric parameters of an irradiation facility. 5. 5. Measurement of absorbed dose distribution in irradiated products. The paper describes these services and the procedures necessary for their execution....

  17. The Antiproton Depth Dose Curve Measured with Alanine Detectors

    DEFF Research Database (Denmark)

    Bassler, Niels; Hansen, Johnny Witterseh; Palmans, Hugo

    2008-01-01

    In this paper we report on the measurement of the antiproton depth dose curve, with alanine detectors. The results are compared with simulations using the particle energy spectrum calculated by FLUKA, and using the track structure model of Hansen et Olsen for conversion of calculated dose...... into response. A good agreement was observed between the measured and calculated relative effectiveness although a slight underestimation of the calculated values in the Bragg peak remains unexplained. The model prediction of response of alanine towards heavy charged particles encourages future use...... of the alanine detectors for dosimetry of mixed radiation fields....

  18. LCR circuit: new simple methods for measuring the equivalent series resistance of a capacitor and inductance of a coil

    Science.gov (United States)

    Ivković, Saša S.; Marković, Marija Z.; Ivković, Dragica Ž.; Cvetanović, Nikola

    2017-09-01

    Equivalent series resistance (ESR) represents the measurement of total energy loss in a capacitor. In this paper a simple method for measuring the ESR of ceramic capacitors based on the analysis of the oscillations of an LCR circuit is proposed. It is shown that at frequencies under 3300 Hz, the ESR is directly proportional to the period of oscillations. Based on the determined dependence of the ESR on the period, a method is devised and tested for measuring coil inductance. All measurements were performed using the standard equipment found in student laboratories, which makes both methods very suitable for implementation at high school and university levels.

  19. Dose area product measurement for diagnostic reference levels and analysis of patient dose in dental radiography

    International Nuclear Information System (INIS)

    Han, S.; Lee, B.; Shin, G.; Choi, J.; Kim, J.; Park, C.; Park, H.; Lee, K.; Kim, Y.

    2008-01-01

    In this study, diagnostic reference levels (DRLs) were suggested and patient doses were analysed through the dose-area product value in dental radiography. In intraoral radiography, at three sites, i.e. molar, premolar and incisor on the maxilla and acquired third quartile values: 55.5, 46 and 36.5 mGy cm 2 , respectively, were measured. In panoramic, cephalo-metric and cone beam computed tomography, the values were 120.3, 146 and 3203 mGy cm 2 (16 x 18 cm), respectively. It has been shown that, in intraoral radiography, the patient dose changes proportionally to the value of mA s, but the change in extra-oral radiography in response to mA s could not be confirmed. The authors could confirm, however, the difference in dose according to the manufacturer in all dental radiography examinations, except for panoramic radiography. Depending on the size of hospital, there were some differences in patient dose in intraoral radiography, but no difference in patient dose in extra-oral radiography. (authors)

  20. Characterisation of an anthropomorphic chest phantom for dose measurements in radiology beams

    International Nuclear Information System (INIS)

    Henriques, L.M.S.; Cerqueira, R.A.D.; Santos, W.S.; Pereira, A.J.S.; Rodrigues, T.M.A.; Carvalho Júnior, A.B.; Maia, A.F.

    2014-01-01

    The objective of this study was to characterise an anthropomorphic chest phantom for dosimetric measurements of conventional radiology beams. This phantom was developed by a previous research project at the Federal University of Sergipe for image quality control tests. As the phantom consists of tissue-equivalent material, it is possible to characterise it for dosimetric studies. For comparison, a geometric chest phantom, consisting of PMMA (polymethylmethacrylate) with dimensions of 30×30×15 cm³ was used. Measurements of incident air kerma (K i ) and entrance surface dose (ESD) were performed using ionisation chambers. From the results, backscatter factors (BSFs) of the two phantoms were determined and compared with values estimated by CALDose X software, based on a Monte Carlo simulation. For the technical parameters evaluated in this study, the ESD and BSF values obtained experimentally showed a good similarity between the two phantoms, with minimum and maximum difference of 0.2% and 7.0%, respectively, and showed good agreement with the results published in the literature. Organ doses and effective doses for the anthropomorphic phantom were also estimated by the determination of conversion coefficients (CCs) using the visual Monte Carlo (VMC) code. Therefore, the results of this study prove that the anthropomorphic thorax phantom proposed is a good tool to use in dosimetry and can be used for risk evaluation of X-ray diagnostic procedures. - Highlights: ► An anthropomorphic chest phantom was to characterise for dosimetric measurements. ► Anthropomorphic phantom developed for image quality can also be used for dosimetry. ► BSFs were compared and showed tendencies found in the literature. ► CCs equivalent and effective doses obtained for the phantom are within the expected

  1. Bio-equivalent doses of recombinant HCG and recombinant LH during ovarian stimulation result in similar oestradiol output

    DEFF Research Database (Denmark)

    Alsbjerg, Birgit; Elbaek, Helle Olesen; Laursen, Rita Jakubcionyte

    2017-01-01

    In nature, HCG is secreted by the implanting embryo from peri-implantation and onwards. In contrast, LH is mandatory for steroidogenesis and follicular development during the follicular phase, working in synergy with FSH. Moreover, LH is mandatory for the function of the corpus luteum. Although LH...... and HCG bind to the same receptor, significant molecular, structural and functional differences exist, inducing differences in bioactivity. This randomized controlled study compared the effect of recombinant FSH stimulation combined with daily either micro-dose recombinant HCG or recombinant LH...... oestradiol level in the HCG supplemented group was 8662 pmol/l versus 9203 pmol/l in the recombinant LH supplemented group; therefore, no significant difference was found. Moreover, no differences were observed in the number of oocytes retrieved or in the live birth rate. We conclude that recombinant HCG...

  2. Reduced recanalization rates of the great saphenous vein after endovenous laser treatment with increased energy dosing: definition of a threshold for the endovenous fluence equivalent.

    Science.gov (United States)

    Proebstle, Thomas Michael; Moehler, Thomas; Herdemann, Sylvia

    2006-10-01

    Recent reports indicated a correlation between the amount of energy released during endovenous laser treatment (ELT) of the great saphenous vein (GSV) and the success and durability of the procedure. Our objective was to analyze the influence of increased energy dosing on immediate occlusion and recanalization rates after ELT of the GSV. GSVs were treated with either 15 or 30 W of laser power by using a 940-nm diode laser with continuous fiber pullback and tumescent local anesthesia. Patients were followed up prospectively with duplex ultrasonography at day 1 and at 1, 3, 6, and 12 months. A total of 114 GSVs were treated with 15 W, and 149 GSVs were treated with 30 W. The average endovenous fluence equivalents were 12.8 +/- 5.1 J/cm2 and 35.1 +/- 15.6 J/cm2, respectively. GSV occlusion rates according to the method of Kaplan and Meier for the 15- and 30-W groups were 95.6% and 100%, respectively, at day 1, 90.4% and 100% at 3 months, and 82.7% and 97.0% at 12 months after ELT (log-rank; P = .001). An endovenous fluence equivalent exceeding 20 J/cm2 was associated with durable GSV occlusion after 12 months' follow-up, thus suggesting a schedule for dosing of laser energy with respect to the vein diameter. Higher dosing of laser energy shows a 100% immediate success rate and a significantly reduced recanalization rate during 12 months' follow-up.

  3. VMAT QA: Measurement-guided 4D dose reconstruction on a patient

    Energy Technology Data Exchange (ETDEWEB)

    Nelms, Benjamin E.; Opp, Daniel; Robinson, Joshua; Wolf, Theresa K.; Zhang, Geoffrey; Moros, Eduardo; Feygelman, Vladimir [Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States); Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida 33612 (United States); Department of Physics, University of South Florida, Tampa, Florida 33612 (United States); Live Oak Technologies LLC, Kirkwood, Missouri 63122 (United States); Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida 33612 (United States)

    2012-07-15

    Purpose: To develop and validate a volume-modulated arc therapy (VMAT) quality assurance (QA) tool that takes as input a time-resolved, low-density ({approx}10 mm) cylindrical surface dose map from a commercial helical diode array, and outputs a high density, volumetric, time-resolved dose matrix on an arbitrary patient dataset. This first validation study is limited to a homogeneous 'patient.'Methods: A VMAT treatment is delivered to a diode array phantom (ARCCHECK, Sun Nuclear Corp., Melbourne, FL). 3DVH software (Sun Nuclear) derives the high-density volumetric dose using measurement-guided dose reconstruction (MGDR). MGDR cylindrical phantom results are then used to perturb the three-dimensional (3D) treatment planning dose on the patient dataset, producing a semiempirical volumetric dose grid. Four-dimensional (4D) dose reconstruction on the patient is also possible by morphing individual sub-beam doses instead of the composite. For conventional (3D) dose comparison two methods were developed, using the four plans (Multi-Target, C-shape, Mock Prostate, and Head and Neck), including their structures and objectives, from the AAPM TG-119 report. First, 3DVH and treatment planning system (TPS) cumulative point doses were compared to ion chamber in a cube water-equivalent phantom ('patient'). The shape of the phantom is different from the ARCCHECK and furthermore the targets were placed asymmetrically. Second, coronal and sagittal absolute film dose distributions in the cube were compared with 3DVH and TPS. For time-resolved (4D) comparisons, three tests were performed. First, volumetric dose differences were calculated between the 3D MGDR and cumulative time-resolved patient (4D MGDR) dose at the end of delivery, where they ideally should be identical. Second, time-resolved (10 Hz sampling rate) ion chamber doses were compared to cumulative point dose vs time curves from 4D MGDR. Finally, accelerator output was varied to assess the linearity of

  4. Measurements of cosmic-ray doses in commercial airline cabins

    International Nuclear Information System (INIS)

    Okano, M.; Fujitaka, K.; Izumo, K.

    1996-01-01

    Cosmic radiation doses which aircrew and air passengers receive in airplanes have been calling attention in many countries especially in the last decade. In this relation, various types of information had been reported on cosmic radiation intensity. In Japan, the cosmic radiation intensity had been measured in commercial airline cabins as well as chartered flights. While the intensity depends on altitude, geomagnetic latitude (or cutoff rigidity), and temporal variation of the solar activity, their doses are often speculated based on paper records on airflights combined with the intensity-altitude relationship. In this study, however, efforts were made to estimate more realistic integrated doses in airline cabins based on actual on-board measurements which had been conducted several dozens of times in each year (e.g., 45 times in 1994 and 27 times in 1995). (author)

  5. Measurement of patient radiation doses in certain urography procedures

    International Nuclear Information System (INIS)

    Sulieman, A.; Barakat, H.; Zailae, A.; Abuderman, A.; Theodorou, K.

    2015-01-01

    Patients are exposed to significant radiation doses during diagnostic and interventional urological procedures. This study aimed to measure patient entrance surface air kerma (ESAK) and to estimate the effective dose during intravenous urography (IVU), extracorporeal shock-wave lithotripsy (ESWL), and ascending urethrogram (ASU) procedures. ESAK was measured in patients using calibrated thermo luminance dosimeters, GR200A). Effective doses (E) were calculated using the National Radiological Protection Board (NRPB) software. A total of 179 procedures were investigated. 27.9 % of the patients underwent IVU procedures, 27.9 % underwent ESWL procedures and 44.2 % underwent ASU procedures. The mean ESAK was 2.1, 4.18 and 4.9 mGy for IVU, ESWL, and ASU procedures, respectively. Differences in patient ESAK for the same procedure were observed. The mean ESAK values were comparable with those in previous studies. (authors)

  6. Medical reference dosimetry using EPR measurements of alanine: Development of an improved method for clinical dose levels

    International Nuclear Information System (INIS)

    Helt-Hansen, Jakob; Andersen, Claus Erik; Rosendal, Flemming; Kofoed, Inger Matilde

    2009-01-01

    Electron spin resonance (EPR) is used to determine the absorbed dose of alanine dosimeters exposed to clinical photon beams in a solid-water phantom. Alanine is potentially suitable for medical reference dosimetry, because of its near water equivalence over a wide energy spectrum, low signal fading, non-destructive measurement and small dosimeter size. Material and Methods. A Bruker EMX-micro EPR spectrometer with a rectangular cavity and a measurement time of two minutes per dosimeter was used for reading of irradiated alanine dosimeters. Under these conditions a new algorithm based on scaling of known spectra was developed to extract the alanine signal. Results. The dose accuracy, including calibration uncertainty, is less than 2% (k=1) above 4 Gy (n=4). The measurement uncertainty is fairly constant in absolute terms (∼30 mGy) and the relative uncertainty therefore rises for dose measurements below 4 Gy. Typical reproducibility is <1% (k=1) above 10 Gy and <2% between 4 and 10 Gy. Below 4 Gy the uncertainty is higher. A depth dose curve measurement was performed in a solid-water phantom irradiated to a dose of 20 Gy at the maximum dose point (dmax) in 6 and 18 MV photon beams. The typical difference between the dose measured with alanine in solid water and the dose measured with an ion chamber in a water tank was about 1%. A difference of 2% between 6 and 18 MV was found, possibly due to non-water equivalence of the applied phantom. Discussion. Compared to previously published methods the proposed algorithm can be applied without normalisation of phase shifts caused by changes in the g-value of the cavity. The study shows that alanine dosimetry is a suitable candidate for medical reference dosimetry especially for quality control applications

  7. Unit of measurement used and parent medication dosing errors.

    Science.gov (United States)

    Yin, H Shonna; Dreyer, Benard P; Ugboaja, Donna C; Sanchez, Dayana C; Paul, Ian M; Moreira, Hannah A; Rodriguez, Luis; Mendelsohn, Alan L

    2014-08-01

    Adopting the milliliter as the preferred unit of measurement has been suggested as a strategy to improve the clarity of medication instructions; teaspoon and tablespoon units may inadvertently endorse nonstandard kitchen spoon use. We examined the association between unit used and parent medication errors and whether nonstandard instruments mediate this relationship. Cross-sectional analysis of baseline data from a larger study of provider communication and medication errors. English- or Spanish-speaking parents (n = 287) whose children were prescribed liquid medications in 2 emergency departments were enrolled. Medication error defined as: error in knowledge of prescribed dose, error in observed dose measurement (compared to intended or prescribed dose); >20% deviation threshold for error. Multiple logistic regression performed adjusting for parent age, language, country, race/ethnicity, socioeconomic status, education, health literacy (Short Test of Functional Health Literacy in Adults); child age, chronic disease; site. Medication errors were common: 39.4% of parents made an error in measurement of the intended dose, 41.1% made an error in the prescribed dose. Furthermore, 16.7% used a nonstandard instrument. Compared with parents who used milliliter-only, parents who used teaspoon or tablespoon units had twice the odds of making an error with the intended (42.5% vs 27.6%, P = .02; adjusted odds ratio=2.3; 95% confidence interval, 1.2-4.4) and prescribed (45.1% vs 31.4%, P = .04; adjusted odds ratio=1.9; 95% confidence interval, 1.03-3.5) dose; associations greater for parents with low health literacy and non-English speakers. Nonstandard instrument use partially mediated teaspoon and tablespoon-associated measurement errors. Findings support a milliliter-only standard to reduce medication errors. Copyright © 2014 by the American Academy of Pediatrics.

  8. NASA Airborne Snow Observatory: Measuring Spatial Distribution of Snow Water Equivalent and Snow Albedo

    Science.gov (United States)

    Joyce, M.; Painter, T. H.; Bormann, K. J.; Berisford, D. F.; Lai-Norling, J.

    2017-12-01

    The two most critical properties for understanding snowmelt runoff and timing are the spatial and temporal distributions of snow water equivalent (SWE) and snow albedo. Despite their importance in controlling volume and timing of runoff, snowpack albedo and SWE are still largely unquantified in the US and not at all in most of the globe, leaving runoff models poorly constrained. NASA Jet Propulsion Laboratory, in partnership with the California Department of Water Resources, has developed the Airborne Snow Observatory (ASO), an imaging spectrometer and scanning LiDAR system, to quantify SWE and snow albedo, generate unprecedented knowledge of snow properties for cutting edge cryospheric science, and provide complete, robust inputs to water management models and systems of the future. This poster will describe the NASA Airborne Snow Observatory, its outputs and their uses and applications, along with recent advancements to the system and plans for the project's future. Specifically, we will look at how ASO uses its imaging spectrometer to quantify spectral albedo, broadband albedo, and radiative forcing by dust and black carbon in snow. Additionally, we'll see how the scanning LiDAR is used to determine snow depth against snow-free acquisitions and to quantify snow water equivalent when combined with in-situ constrained modeling of snow density.

  9. Measurement of radiation dose in paediatric micturating cystourethrography

    International Nuclear Information System (INIS)

    Hassan, N. E. A.

    2013-06-01

    Paediatrics and children have been recognized that they have a higher risk of developing cancer from the radiation than adults. Therefor, increased attention has been directed towards the dose to the patients. Micturating Cystourethrography (MCU) is a commonly use ed fluoroscopic procedure in children and commonly used to detect the vesicoureteric reflux (VUR) and show urethral and bladder and abnormalities. This study aims to measure the pediatric patients undergoing MCU. The study was carried out in two hospitals in Khartoum. The entrance surface dose (ESD) was determined determined by indirect method for 45 children. Furthermore, the mean ESD, sd and range resulting from MCU procedures has been estimated to be 0.7±.5 (0.2-2.5) mGy for the total patient population. The radiation dose to the patients is well within established safety limits, in the light of the current practice. The radiation dose results of this study are appropriate for adoption as the local initial dose reference level (DRL) value for this technique. The data presented in this study showed our doses to be approximately 50% lower than the lower mean values presented in the literature.(Author)

  10. A study of a measure for reducing radiation dose in dental radiography for children

    International Nuclear Information System (INIS)

    Tateno, Hidemi

    1982-01-01

    For this investigation the author employed the stabilized TLD and measured the effect of doses on several organs (of children) using water and Mix-D phantom. Based upon this data, the author developed an exposure cone (of children) which was thought to be the best concrete method for reduction of absorbed doses for children who are most frequentry X-rayed and therefore most likely to reduced absorbed doses in a considerable amount. The major findings have been obtained concerning this cone compared with the standard cone as follows. 1. The full mouth 6-film examination showed the largest of the absorbed doses to be on skin, eyes and the thyroid gland. 2. For example, the dose on thyroid gland with a full mouth 6-film examination was 0.734R. 3. The dose on the gonad was less than 0.001R with every technique. 4. Using the developed exposure cone for children we have succeeded in reducing the amount of doses on these organs. In addition the image quality improved due to the reduction of scattered X-rays. 5. Using the developed exposure cone (for children) the risk of thyroid cancer can be reduced a level of 10 -6 to a level of 10 -7 as compared with the standard exposure cone. 6. Supposing that it is over the crystalline lens limits of dose-equivalent in a year at several times with full mouth 6-film examinations can be estimated which with standard cone was about three times, developed cone was about eighty-eight times in a year. (J.P.N.)

  11. Differences between near-surface equivalent temperature and temperature trends for the Eastern United States. Equivalent temperature as an alternative measure of heat content

    Science.gov (United States)

    Davey, C.A.; Pielke, R.A.; Gallo, K.P.

    2006-01-01

    There is currently much attention being given to the observed increase in near-surface air temperatures during the last century. The proper investigation of heating trends, however, requires that we include surface heat content to monitor this aspect of the climate system. Changes in heat content of the Earth's climate are not fully described by temperature alone. Moist enthalpy or, alternatively, equivalent temperature, is more sensitive to surface vegetation properties than is air temperature and therefore more accurately depicts surface heating trends. The microclimates evident at many surface observation sites highlight the influence of land surface characteristics on local surface heating trends. Temperature and equivalent temperature trend differences from 1982-1997 are examined for surface sites in the Eastern U.S. Overall trend differences at the surface indicate equivalent temperature trends are relatively warmer than temperature trends in the Eastern U.S. Seasonally, equivalent temperature trends are relatively warmer than temperature trends in winter and are relatively cooler in the fall. These patterns, however, vary widely from site to site, so local microclimate is very important. ?? 2006 Elsevier B.V. All rights reserved.

  12. Experimental study and finite element analysis based on equivalent load method for laser ultrasonic measurement of elastic constants.

    Science.gov (United States)

    Zhan, Yu; Liu, Changsheng; Zhang, Fengpeng; Qiu, Zhaoguo

    2016-07-01

    The laser ultrasonic generation of Rayleigh surface wave and longitudinal wave in an elastic plate is studied by experiment and finite element method. In order to eliminate the measurement error and the time delay of the experimental system, the linear fitting method of experimental data is applied. The finite element analysis software ABAQUS is used to simulate the propagation of Rayleigh surface wave and longitudinal wave caused by laser excitation on a sheet metal sample surface. The equivalent load method is proposed and applied. The pulsed laser is equivalent to the surface load in time and space domain to meet the Gaussian profile. The relationship between the physical parameters of the laser and the load is established by the correction factor. The numerical solution is in good agreement with the experimental result. The simple and effective numerical and experimental methods for laser ultrasonic measurement of the elastic constants are demonstrated. Copyright © 2016. Published by Elsevier B.V.

  13. Ionizing radiation measurements and assay of corresponding dose

    African Journals Online (AJOL)

    PUBLICATIONS1

    Measurements of ionizing radiation and corresponding dose rate around bottling and pharma- ceutical facilities in Ilorin, Nigeria, have been ... hanced naturally occurring radioactive materi- als are produced as a result of industrial activi- ... that the quality of our environment be main- tained in a good state, to ensure a high ...

  14. Dose-area product measurement for patients in diagnostic radiography

    International Nuclear Information System (INIS)

    Alkhawad, Safaa Ibrahim Awad Elkarim

    2001-09-01

    There is a wide spread of the utilization of medical diagnostic x-ray in Sudan upon the last years, in private clinics as well as in public hospitals. The aim of this study was to measure the doses to patients from x-ray in radiography departments in Khartoum State. Use was made of ionization chamber that measures the product of dose times the exposed area of the patient in units of Gy cm 2 . The work was performed in 7 hospitals over 250 patients. 71.2% of the patients were males and 28.8% females. From this work, it appears that the chest radiography represent 42% of the total exposure of human body organs to radiography, there was also a clear variation in doses resulting from this exposure for different x-ray machines. The results of this study were compared with similar from Germany, Finland, New Zealand and Norway; which are recently available studies. The comparison showed those investigation of abdomen, spine and pelvis result in higher radiation doses. No data for limb exposure were obtained from these countries, in Sudan exposure of the limb carry radiation doses compared to the rest of the human body.(Author)

  15. Precedents For Authorization Of Contents Using Dose Rate Measurements

    International Nuclear Information System (INIS)

    Abramczyk, G.; Bellamy, S.; Nathan, S.; Loftin, B.

    2012-01-01

    For the transportation of Radioactive Material (RAM) packages, the requirements for the maximum allowed dose rate at the package surface and in its vicinity are given in Title 10 of the Code of Federal Regulations, Section 71.47. The regulations are based on the acceptable dose rates to which the public, workers, and the environment may be exposed. As such, the regulations specify dose rates, rather than quantity of radioactive isotopes and require monitoring to confirm the requirements are met. 10CFR71.47 requires that each package of radioactive materials offered for transportation must be designed and prepared for shipment so that under conditions normally incident to transportation the radiation level does not exceed 2 mSv/h (200 mrem/h) at any point on the external Surface of the package, and the transport index does not exceed 10. Before shipment, the dose rate of the package is determined by measurement, ensuring that it conforms to the regulatory limits, regardless of any analyses. This is the requirement for all certified packagings. This paper discusses the requirements for establishing the dose rates when shipping RAM packages and the precedents for meeting these requirements by measurement.

  16. Peripheral dose measurement in breast cancer patients submitted to Tomotherapy using thermoluminescent dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Medina A, O.; Medrano S, A. C.; Azorin N, J. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico); Mora G, L. C., E-mail: omedina@xanum.uam.mx [IMSS, Centro Medico Nacional Siglo XXI, Av. Cuauhtemoc 330, 06725 Mexico D. F. (Mexico)

    2015-10-15

    Full text: Thermoluminescence dosimetry (TLD) has been one of the most important techniques in medical radiation applications over many years, creating opportunities of advancing in novel radiotherapy techniques particularly in Tomotherapy with photons. LiF:Mg,Ti TLD is one kind of TLD which can be used in Tomotherapy because of having suitable properties such as good sensitivity, small size and tissue equivalence. Hypo fractionation is a radiotherapeutic technique, widely accepted as an important treatment for breast cancer patients, characterized by high doses at which they are exposed for treatment of cancerous tumors that are irradiated precisely with photons from a helical accelerator and aims to decrease the number of sessions from 3 - 6 weeks to 1 - 3 weeks. Results of measuring the peripheral dose (Pd) in breast cancer patients submitted to Tomotherapy with high-energy photons are presented. (Author)

  17. Development of a computational model for the calculation of neutron dose equivalent in laminated primary barriers of radiotherapy rooms

    International Nuclear Information System (INIS)

    Rezende, Gabriel Fonseca da Silva

    2015-01-01

    Many radiotherapy centers acquire 15 and 18 MV linear accelerators to perform more effective treatments for deep tumors. However, the acquisition of these equipment must be accompanied by an additional care in shielding planning of the rooms that will house them. In cases where space is restricted, it is common to find primary barriers made of concrete and metal. The drawback of this type of barrier is the photoneutron emission when high energy photons (e.g. 15 and 18 MV spectra) interact with the metallic material of the barrier. The emission of these particles constitutes a problem of radiation protection inside and outside of radiotherapy rooms, which should be properly assessed. A recent work has shown that the current model underestimate the dose of neutrons outside the treatment rooms. In this work, a computational model for the aforementioned problem was created from Monte Carlo Simulations and Artificial Intelligence. The developed model was composed by three neural networks, each being formed of a pair of material and spectrum: Pb18, Pb15 and Fe18. In a direct comparison with the McGinley method, the Pb18 network exhibited the best responses for approximately 78% of the cases tested; the Pb15 network showed better results for 100% of the tested cases, while the Fe18 network produced better answers to 94% of the tested cases. Thus, the computational model composed by the three networks has shown more consistent results than McGinley method. (author)

  18. A simplified, improved method for making amplifier equivalent noise charge measurements using a new generation digitizing oscilloscope

    International Nuclear Information System (INIS)

    Zimmerman, T.

    1990-10-01

    Historically a variety of methods have been used to measure the equivalent noise charge (ENC) of amplifier/shaper systems for high energy physics. Some of these methods require several pieces of special test equipment and a fair amount of effort. The advent of digitizing oscilloscopes with statistics capabilities makes it possible to perform certain types of noise measurements accurately with very little effort. This paper describes the noise measurement method of a time invariant amplifier/shaper and of a time variant correlated sampling system, using a Tektronix DSA602 Digitizing Signal Analyzer. 4 figs

  19. Calculation of conversion coefficients for air kerma to ambient dose equivalent using transmitted spectra of megavoltage X-rays through concrete.

    Science.gov (United States)

    Cordeiro, T P V; Silva, A X

    2012-12-01

    With the fast advancement of technology, (60)Co teletherapy units are largely being replaced with medical linear accelerators. In most cases, the linear accelerator tends to be installed in the same room in which the (60)Co teletherapy unit was previously placed. If in-depth structural remodelling is out of the question, high-density concrete is usually used to improve shielding against primary, scatter and leakage radiation originating in the new equipment. This work presents a study based on Monte Carlo simulations of the transmission of some clinical photon spectra (from 6, 10, 15, 18 and 25 MV accelerators) through concrete, considering two different densities. Concrete walls with thickness ranging from 0.70 to 2.0 m were irradiated with 30 cm×30 cm primary beam spectra. The results show that the thickness of the barrier decreases up to ∼65 % when barite (high-density concrete) is used instead of ordinary concrete. The average energies of primary and transmitted beam spectra were also calculated. In addition, conversion coefficients from air kerma to ambient dose equivalent, H*(d)/K(air), and air kerma to effective dose, E/K(air), for photon spectra from the transmitted spectra were calculated and compared. The results suggest that the 10-mm depth is not the best choice to represent the effective dose.

  20. Routine measurement of dose to the bladder: still an utopy?

    International Nuclear Information System (INIS)

    Schaeken, B.; Goor, C.; Weyngaert, D. van den; Middelheim, A.Z.

    1996-01-01

    Dosimetry with alanine is based on the relative and non destructive measurement of stable free radicals produced by radiation. The flexibility of the method (linear dose response, no energy dependence, no dose rate dependence) as well as in detector design makes this method very suited as in vivo dosimetry system for brachytherapy. Absorbed dose to the detector is measured as the signal intensity of the central line of the electron paramagnetic resonance (EPR) powder spectrum of alanine. The dose at the bladder reference point (ICRU 38) can be measured with no additional inconvenience to the patient using a liquid alanine detector (natural oil with alanine crystals of size less than 200 mm) as follows: the balloon of the Foley catheter is filled with ± 7 cc of liquid detector instead of a radio-opaque fluid. By sedimentation the alanine crystals are collected at the posterior surface of the balloon in the vicinity of the bladder reference point. After the treatment the detector is recuperated from the Foley catheter and read out using a small quartz tube. In vitro measurements revealed 1) a perfect linear dose response in the range between 2 Gy and 5 Gy; 2) highly reproducible measurements: 3% (1s) at 1 Gy, 0.3% (1s) at 50 Gy; 3) a minor quantity of oil is leaking through the balloon wall which we expect is of no harm to the patient; 4) retrieving the irradiated alanine crystals from the Foley catheter reduces the EPR signal with a factor 0.927 ± 0.003 (1s); 5) subsequent mixing followed by centrifuge of the detector fluid will result in an EPR signal stable within ± 1% (1s); 6) the detector fluid shows an excellent EPR stability in a period of months after irradiation. We only recently obtained permission of the ethical committee to use this technique in vivo; the results of at least one patient will be discussed

  1. Effective dose measurement at workplaces within an instrumented anthropomorphic phantom

    International Nuclear Information System (INIS)

    Villagrasa, C.; Darreon, J.; Martin-Burtat, N.; Clairand, I.; Colin, J.; Fontbonne, J. M.

    2011-01-01

    The Laboratory of Ionizing Radiation Dosimetry of the IRSN (France) is developing an instrumented anthropomorphic phantom in order to measure the effective dose for photon fields at workplaces. This anthropomorphic phantom will be equipped with small active detectors located inside at chosen positions. The aim of this paper is to present the development of these new detectors showing the results of the characterisation of the prototype under metrological conditions. New evaluations of the effective dose for standard and non-homogenous irradiation configurations taking into account the real constraints of the project have been done validating the feasibility and utility of the instrument. (authors)

  2. KERMA-based radiation dose management system for real-time patient dose measurement

    Science.gov (United States)

    Kim, Kyo-Tae; Heo, Ye-Ji; Oh, Kyung-Min; Nam, Sang-Hee; Kang, Sang-Sik; Park, Ji-Koon; Song, Yong-Keun; Park, Sung-Kwang

    2016-07-01

    Because systems that reduce radiation exposure during diagnostic procedures must be developed, significant time and financial resources have been invested in constructing radiation dose management systems. In the present study, the characteristics of an existing ionization-based system were compared to those of a system based on the kinetic energy released per unit mass (KERMA). Furthermore, the feasibility of using the KERMA-based system for patient radiation dose management was verified. The ionization-based system corrected the effects resulting from radiation parameter perturbations in general radiography whereas the KERMA-based system did not. Because of this difference, the KERMA-based radiation dose management system might overestimate the patient's radiation dose due to changes in the radiation conditions. Therefore, if a correction factor describing the correlation between the systems is applied to resolve this issue, then a radiation dose management system can be developed that will enable real-time measurement of the patient's radiation exposure and acquisition of diagnostic images.

  3. Absorbed photon dose measurement and calculation for some patient organs examined by computed tomography

    Science.gov (United States)

    Shousha, Hany A.

    Patient doses from computed tomography (CT) examinations are usually expressed in terms of dose index, organ doses, and effective dose. The CT dose index (CTDI) can be measured free-in-air or in a CT dosimetry phantom. Organ doses can be measured directly in anthropomorphic Rando phantoms using thermoluminescent detectors. Organ doses can also be calculated by the Monte Carlo method utilizing measured CTDI values. In this work, organ doses were assessed for three main CT examinations: head, chest, and abdomen, using the different mentioned methods. Results of directly measured doses were compared with calculated doses for different organs in the study, and also compared with published international studies.

  4. The direct measurement of dose enhancement in gamma test facilities

    International Nuclear Information System (INIS)

    Burke, E.A.; Snowden, D.P.; Cappelli, J.R.; Mittleman, S.; Lowe, L.F.

    1989-01-01

    The design and use of a dual cavity ionization chamber for routine measurement of dose enhancement factors in Co-60 gamma test facilities is described. The enhancement factors can be derived directly from the chamber measurements without recourse to reference data that may be difficult to obtain. It is shown, in agreement with earlier work, that the maximum dose enhancement factors can be altered by a factor two as a result of Compton scatter from relatively small amounts of low or high atomic number materials next to the target. The dual chamber permits the ready detection of such effects. This relatively simple device reliably reproduced earlier results obtained by more involved equipment and procedures. Measured enhancement factors are reported for new material combinations not previously examined and compared with recent calculations

  5. Dose measurements in space by the Hungarian Pille TLD system

    Energy Technology Data Exchange (ETDEWEB)

    Apathy, I.; Deme, S. E-mail: deme@sunserv.kfki.hu; Feher, I.; Akatov, Y.A.; Reitz, G.; Arkhanguelski, V.V

    2002-10-01

    Exposure of crew, equipment, and experiments to the ambient space radiation environment in low Earth orbit poses one of the most significant problems to long-term space habitation. Accurate dose measurement has become increasingly important during the assembly (extravehicular activity (EVA)) and operation of space stations such as on Space Station Mir. Passive integrating detector systems such as thermoluminescent dosemeters (TLDs) are commonly used for dosimetry mapping and personal dosimetry on space vehicles. The well-known advantages of passive detector systems are their independence of power supply, small dimensions, high sensitivity, good stability, wide measuring range, resistance to environmental effects, and relatively low cost. Nevertheless, they have the general disadvantage that for evaluation purposes they need a laboratory or large--in mass and power consumption--terrestrial equipment, and consequently they cannot provide time-resolved dose data during long-term space flights. KFKI Atomic Energy Research Institute (KFKI AEKI) has developed and manufactured a series of thermoluminescent dosemeter systems for measuring cosmic radiation doses in the 10 {mu}Gy to 10 Gy range, consisting of a set of bulb dosemeters and a compact, self-contained, TLD reader suitable for on-board evaluation of the dosemeters. By means of such a system, highly accurate measurements were carried out on board the Salyut-6, -7 and Mir Space Stations as well as on the Space Shuttle. A detailed description of the system is given and the comprehensive results of these measurements are summarised.

  6. Dose measurements in space by the Hungarian Pille TLD system

    International Nuclear Information System (INIS)

    Apathy, I.; Deme, S.; Feher, I.; Akatov, Y.A.; Reitz, G.; Arkhanguelski, V.V.

    2002-01-01

    Exposure of crew, equipment, and experiments to the ambient space radiation environment in low Earth orbit poses one of the most significant problems to long-term space habitation. Accurate dose measurement has become increasingly important during the assembly (extravehicular activity (EVA)) and operation of space stations such as on Space Station Mir. Passive integrating detector systems such as thermoluminescent dosemeters (TLDs) are commonly used for dosimetry mapping and personal dosimetry on space vehicles. The well-known advantages of passive detector systems are their independence of power supply, small dimensions, high sensitivity, good stability, wide measuring range, resistance to environmental effects, and relatively low cost. Nevertheless, they have the general disadvantage that for evaluation purposes they need a laboratory or large--in mass and power consumption--terrestrial equipment, and consequently they cannot provide time-resolved dose data during long-term space flights. KFKI Atomic Energy Research Institute (KFKI AEKI) has developed and manufactured a series of thermoluminescent dosemeter systems for measuring cosmic radiation doses in the 10 μGy to 10 Gy range, consisting of a set of bulb dosemeters and a compact, self-contained, TLD reader suitable for on-board evaluation of the dosemeters. By means of such a system, highly accurate measurements were carried out on board the Salyut-6, -7 and Mir Space Stations as well as on the Space Shuttle. A detailed description of the system is given and the comprehensive results of these measurements are summarised

  7. 128 slice computed tomography dose profile measurement using thermoluminescent dosimeter

    International Nuclear Information System (INIS)

    Salehhon, N; Hashim, S; Karim, M K A; Ang, W C; Musa, Y; Bahruddin, N A

    2017-01-01

    The increasing use of computed tomography (CT) in clinical practice marks the needs to understand the dose descriptor and dose profile. The purposes of the current study were to determine the CT dose index free-in-air (CTDI air ) in 128 slice CT scanner and to evaluate the single scan dose profile (SSDP). Thermoluminescent dosimeters (TLD-100) were used to measure the dose profile of the scanner. There were three sets of CT protocols where the tube potential (kV) setting was manipulated for each protocol while the rest of parameters were kept constant. These protocols were based from routine CT abdominal examinations for male adult abdomen. It was found that the increase of kV settings made the values of CTDI air increased as well. When the kV setting was changed from 80 kV to 120 kV and from 120 kV to 140 kV, the CTDI air values were increased as much as 147.9% and 53.9% respectively. The highest kV setting (140 kV) led to the highest CTDI air value (13.585 mGy). The p -value of less than 0.05 indicated that the results were statistically different. The SSDP showed that when the kV settings were varied, the peak sharpness and height of Gaussian function profiles were affected. The full width at half maximum (FWHM) of dose profiles for all protocols were coincided with the nominal beam width set for the measurements. The findings of the study revealed much information on the characterization and performance of 128 slice CT scanner. (paper)

  8. Calculation by the Monte Carlo method of the equivalent dose received by a human fetus from gamma sources localized in the gastrointestinal tract

    International Nuclear Information System (INIS)

    Segreto, V.S.A.

    1979-01-01

    New uterus positions are proposed and worked out in detail to evaluate the exposure of the human fetus to radiation originated in the gastrointestinal-tract during the pregnancy period. In our evaluation each organ in the gastrointestinal-tract namely stomach, small intestine, transverse colon, ascendent colon, descendent colon, sigmoid and rectum was individually considered. Changes in the position of each of these organs were studied as a function of the uterus growth. There were evaluated cases in which the uterus was in three, six and nine month pregnancy for photon energies of 0.02, 0.05, 0.10, 0.50 and 4 MeV. The average equivalent doses (H) of the uterus, in the uterine wall and in each one of the twelve compartiments which we considered as sub-divisions of the uterus were also determined and discussed. (Auhor) [pt

  9. Analysis simulation of tectonic earthquake impact to the lifetime of radioactive waste container and equivalent dose rate predication in Yucca Mountain geologic repository, Nevada test site, USA

    International Nuclear Information System (INIS)

    Ko, I.S.; Imardjoko, Y.U.; Karnawati, Dwikorita

    2003-01-01

    US policy not to recycle her spent nuclear fuels brings consequence to provide a nuclear waste repository site Yucca Mountain in Nevada, USA, considered the proper one. High-level radioactive waste to be placed into containers and then will be buried in three hundred meter underground tunnels. Tectonic earthquake is the main factor causing container's damage. Goldsim version 6.04.007 simulates mechanism of container's damage due to a great devastating impact load, the collapse of the tunnels. Radionuclide inventories included are U-234, C-14, Tc-99, I-129, Se-79, Pa-231, Np-237, Pu-242, and Pu-239. Simulation carried out in 100,000 years time span. The research goals are: 1). Estimating tunnels stan-up time, and 2). Predicting the equivalent dose rate contributed by the included radionuclides to the human due to radioactive polluted drinking water intake. (author)

  10. Determination of attenuation factors for mortar of barite in terms of environmental dose equivalent and effective dose; Determinacao de fatores de atenuacao para argamassa de barita em termos do equivalente de dose ambiental e dose efetiva

    Energy Technology Data Exchange (ETDEWEB)

    Almeida Junior, Airton T.; Campos, L.L.R., E-mail: airtontavares@uol.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Araujo, F.G.S. [Universidade Federal de Ouro Preto (UFOP), Ouro Preto, MG (Brazil); Santos, M.A.P. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Nogueira, M.S., E-mail: mnogueira@cdtn.br [Centro de Desenvolvimeto da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2014-07-01

    This work addresses the characterization of barite mortars used as Xray shielding materials through the following quantities: mass attenuation coefficient, air kerma, effective dose and ambient dose - H⁎(10). The experiment was carried out with the use of the following reference qualities: RQR4, RQR6, RQR9 e RQR10, specified in accordance with norm IEC 61267: Medical diagnostic Xray equipment - radiation conditions for use in the determination of characteristics. In this study values was determined experimentally for the attenuation of the Cream barite (density 2.99g/cm{sup 3}, collected in the state of Sao Paulo), Purple barite (density 2.95g/cm{sup 3}, collected in the state of Bahia) and White barite (density 3.10g/cm{sup 3}, collected in the state of Paraiba). These materials, in the form of mortar, were disposed in the form of squares namely poof bodies, whose dimensions were 10 x 10 cm and thickness ranging from 3 to 15 mm approximately. In the experimental procedure, these proof bodies were irradiated with a Pantak, model HF320 industrial X-ray apparatus. The potentials applied to the respective X-ray tube were: 60kV, 80kV, 120kV and 150kV at a constant current of 1mA. The attenuation responses in function of thickness, for each of the materials analyzed, were used to draw the attenuation and transmission curves. The efficiency of the barite studied concerning the capacity to attenuate X-ray radiation for X-ray beams ranging from 60 to 150 kV indicated.

  11. Calculation Monte Carlo equivalent dose to organs in a treatment of prostate with Brachytherapy of high rate; Calculo Monte Carlo de dosis equivalente a organos en un tratamiento de prostata con braquiterapia de alta tasa

    Energy Technology Data Exchange (ETDEWEB)

    Candela-Juan, C.; Vijande, J.; Granero, D.; Ballester, F.; Perez-Calatayud, J.; Rivard, M. J.

    2013-07-01

    The objective of this study was to obtain equivalent dose to radiosensitive organs when applies brachytherapy high dose (HDR) with sources of 60 Co or 192 Go to a localized carcinoma of the prostate. The results are compared with those reported in the literature on treatment with protons and intensity modulated (IMRT) radiation therapy. (Author)

  12. Comparing Hp(3) evaluated from the conversion coefficients from air kerma to personal dose equivalent for eye lens dosimetry calibrated on a new cylindrical PMMA phantom

    Science.gov (United States)

    Esor, J.; Sudchai, W.; Monthonwattana, S.; Pungkun, V.; Intang, A.

    2017-06-01

    Based on a new occupational dose limit recommended by ICRP (2011), the annual dose limit for the lens of the eye for workers should be reduced from 150 mSv/y to 20 mSv/y averaged over 5 consecutive years in which no single year exceeding 50 mSv. This new dose limit directly affects radiologists and cardiologists whose work involves high radiation exposure over 20 mSv/y. Eye lens dosimetry (Hp(3)) has become increasingly important and should be evaluated directly based on dosimeters that are worn closely to the eye. Normally, Hp(3) dose algorithm was carried out by the combination of Hp(0.07) and Hp(10) values while dosimeters were calibrated on slab PMMA phantom. Recently, there were three reports from European Union that have shown the conversion coefficients from air kerma to Hp(3). These conversion coefficients carried out by ORAMED, PTB and CEA Saclay projects were performed by using a new cylindrical head phantom. In this study, various delivered doses were calculated using those three conversion coefficients while nanoDot, small OSL dosimeters, were used for Hp(3) measurement. These calibrations were performed with a standard X-ray generator at Secondary Standard Dosimetry Laboratory (SSDL). Delivered doses (Hp(3)) using those three conversion coefficients were compared with Hp(3) from nanoDot measurements. The results showed that percentage differences between delivered doses evaluated from the conversion coefficient of each project and Hp(3) doses evaluated from the nanoDots were found to be not exceeding -11.48 %, -8.85 % and -8.85 % for ORAMED, PTB and CEA Saclay project, respectively.

  13. Establishing score equivalence of the Functional Independence Measure motor scale and the Barthel Index, utilising the International Classification of Functioning, Disability and Health and Rasch measurement theory

    OpenAIRE

    Prodinger, B; O'Connor, RJ; Stucki, G; Tennant, A

    2017-01-01

    Introduction: Two widely used outcome measures to assess functioning in neurological rehabilitation are the Functional Independence Measure (FIM™) and the Barthel Index. The current study aims to establish the equivalence of the total score of the FIM™ motor scale and the Barthel Index through the application of the International Classification of Functioning, Disability and Health, and Rasch measurement theory. Methods: Secondary analysis of a large sample of patients with stroke, spinal cor...

  14. Dose measurements in laboratory of Physics department, University of Khartoum

    International Nuclear Information System (INIS)

    Hamid, Maria Mohammed

    1999-05-01

    Personal monitoring in University of Khartoum is being conducted using thermoluminescent dosimetry. The purpose of the study is to measure the dose of radiation in laboratory of Physics in physics department. TL phosphors LiF: Mg, Ti (card) and LiF Mg, Cu, P (GR-200) and mini-rad dosimeter are used to measure the dose in laboratory. The total dose for students form the laboratory bu using card, GR-200 and mini-rad dosimeter was found to be 2.2μ sv/year. 2.5 μ sv/year and 2.6 μ sv respectively, and for the teacher about 4.0 μ sv/year, 5.8 μ sv/year and 13.6 μ sv/year respectively, and for the dose near junk room about 3.9 μ sv/year, 2.9 μ sv/year and 2.8 μ sv/year by using card, GR-200 and mini-rad dosimeter respectively. There is just a background radiation in the main library and the applied nuclear.(Author)

  15. Measurement of doses to aviator pilots using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin N, J.; Cruz C, D.; Rivera M, T.

    2004-01-01

    During the development of their work, the aviator pilots are exposed at high levels of natural radiation of bottom caused mainly by the cosmic radiation of galactic origin and lot. For such reason, the Metropolitan Autonomous University (UAM) and the Union Association of Aviator Pilots (ASPA), subscribed an agreement with the purpose of to measure the doses of ionizing radiation received by the aviator pilots of diverse air companies that man different types of airships and to determine if these doses surpass the one limit of 0.11 mSv/h settled down by the IAEA for the public in general; and if therefore, these workers should be considered as personnel occupationally exposed. In this work the obtained results when measuring the absorbed dose received by Mexican civil aviator pilots during the development of their work, using thermoluminescent dosemeters of LiF:Mg,Cu,P + Ptfe of national production are presented. The obtained results during the years of 2001 and 2002 show that the monthly doses received by the pilots surpass the one it limits established for the public in general, for what they should be considered as personnel occupationally exposed. (Author)

  16. Entrance surface dose measurements in mammography using thermoluminescence technique

    International Nuclear Information System (INIS)

    Rivera, T.; Vega C, H.R.; Manzanares A, E; Azorin, J.; Gonzalez, P.R.

    2007-01-01

    Full text: Of the various techniques that can be used for personnel dosimetry, thermoluminescence dosimetry (TLD) has emerged as a superior technique due to its manifold advantages over other methods of dose estimation. Various phosphors have been therefore investigated regarding their suitability for dosimetry. In this paper, a dosimetry system based on thermally stimulated luminescence (TSL) from zirconium oxide phosphors embedded in polytetrafluorethylene (ZrO 2 +PTFE) was developed for entrance surface doses (ES) measurements in mammography. Small ZrO 2 pellets of 5 mm in diameter and 0.8 mm in thickness were used. The reproducibility of measurements and linearity of ZrO 2 were also studied. The results were compared with those obtained from LiF:Mg,Cu,P usually used for the determination of absorbed dose in mammography. Measurements both per unit air kerma and In vivo were performed using a mammography unit model DMR (General Electric). The results showed that ZrO 2 TLDs can be used for the same X-ray dosimetry applications as LiF:Mg,Cu,P, with each type having the disadvantage of a response dependent on energy, particularly at low energies. These results indicate a considerable potential for use in routine control and In vivo ES measurements in mammography. (Author)

  17. Portal dose measurement in radiotherapy using an electronic portal imaging device (EPID)

    International Nuclear Information System (INIS)

    Heijmen, B.J.M.; Pasma, K.L.; Kroonwijk, M.; Boer, J.C.J. de; Visser, A.G.; Huizenga, H.; Althof, V.G.M.

    1995-01-01

    Physical characteristics of a commercially available electronic portal imaging device (EPID), relevant to dosimetric applications in high-energy photon beams, have been investigated. The EPID basically consists of a fluorescent screen, mirrors and a CCD camera. Image acquisition for portal dose measurement has been performed with a special procedure, written in the command language that comes with the system. The observed day-to-day variation in local EPID responses, i.e. measured grey scale value (EPID signal) per unit of delivered portal dose, is 0.4% (1 SD); day-to-day variations in relative EPID responses (e.g. normalized to the on-axis response) are within 0.2% (1 SD). Measured grey scale values are linearly proportional to transmitted portal doses with a proportionality constant which is independent of the thickness of a flat, water-equivalent absorber in the beam, but which does significantly depend on the size of the applied X-ray beam. It is shown that the observed increase in EPID response with increasing field size is mainly due to contributions to the EPID signals from scattered light: visible photons produced by the X-ray beam in a point of the fluorescent screen not only generate a grey scale value in the corresponding point of the EPID image, but also lead (due to scatter from components of the EPID structure onto the CCD chip) to an increased grey scale value at all other points of the image. (Author)

  18. Determination of the dose equivalent Hp(0.07) in hands of occupationally exposed personnel in the practice of proton emission tomography (PET/CT); Determinacion de la dosis equivalente Hp(0.07) en manos de trabajadores ocupacionalmente expuestos en la practica de Tomografia por Emision de Positrones (PET/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Lea, D. [Servicio de Radiofisica Sanitaria, Unidad de Tecnologia Nuclear, Instituto Venezolano de Investigaciones Cientificas, Ministerio de Ciencia y Tecnologia, Km 11 Carretera Panamerican, Altos del Pipe, Caracas (Venezuela); Ruiz, N.; Esteves, L. [Centro Diagnostico Docente Las Mercedes, Calle Paris cruce con calle Caroni, Edif. CDD, Las Mercedes, Caracas (Venezuela)]. e-mail: dlea@ivic.ve

    2006-07-01

    In Venezuela recently it was implanted the Positron Emission Tomography technique (PET) with the perspective of implanting it at national level. Even when in our country practices it of nuclear medicine it exists from early of 70, there is not experience in the determination of the occupational doses by exposure to the external radiation in hands. By this reason, a concern exists in the workers of the centers of nuclear medicine where it is practiced the Positron Emission Tomography technique. In absence of the TLD dosimetry to measure dose in hands in our country, measurements of the dose equivalent of the workers of the PET national reference center were made, using a detector of hands type diode. It was determined the dose in hands in terms of dose equivalent Hp(0.07) in two work positions, that is: the corresponding to the transfer of the receiving vial of ({sup 18}F) FDG to the shield, quality control and uni doses division. The second work position corresponds the person in charge of administering, via intravenous, the ({sup 18}F) FDG. In this work it realizes the dose equivalent in hands Hp(0.07) measures in each one of the work positions before described by daily production. The informed doses correspond to a total average produced activity of 20.4 GBq (550 mCi). The results of the measurements in terms of dose equivalent in hands Hp(0.07) correspond to 2.1 {+-} 20% mSv in the work position of division and 0.4 {+-} 10% mSv in the position of injection of the radioactive material. At short term this foreseen until 4 productions per week, what means an annual dose equivalent Hp(0.07) in hands of 400 mSv approximately, without taking into account abnormal situations as its are spills of the ({sup 18}F) FDG in the work place. This work is the starting point so that the regulatory authority settles down, in Venezuela, dose restrictions in the PET practices and implant, in the centers of nuclear medicine, an optimization politics of this practice in conformity

  19. Dose measurement of fast electrons with a modified Fricke solution

    International Nuclear Information System (INIS)

    Nemec, H.W.; Roth, J.; Luethy, H.

    1975-01-01

    A combination of two different modifications indicated in the literature about the ferrosulfate dosimetry is given. This permits a dose measurement which shows compared to the usual Fricke dosimetry above all following advantages: dose specification related to water; displacement of the absorption maximum in the perceptible spectral sphere; increase of the sensibility and lower influence of pollutions. The molar coefficient of extinction of the modified solution has been determined from 60 Co gamma irradiation and is epsilonsub(m) = 1.46 x 10 4 l x Mol -1 x cm -1 . The increase of extinction which has been measured with this method after the irradiation with 18 MeV electrons occurs linearly within the studied region to 1,200 rd at least, the G-value is 15.5. The indicated method renders possible a relative simple calibration of the ionization chambers used in the practice. (orig.) [de

  20. Dose Measurements in a 20-J Repetitive Plasma Focus

    Science.gov (United States)

    Goudarzi, S.; Babaee, H.; Esmaeli, A.; Nasiri, A.; Mazandarani, A.

    2018-02-01

    In this article, the results of X-ray dose measurements executed using thermoluminescent dosimeters in experiments with a very small (20 J) repetitive plasma focus device named SORENA-1 are presented and analyzed. The working gas in these experiments was Argon. Also, pinch formation in experiments with this device has been observed. This device has been designed and constructed in Plasma and Nuclear Fusion Research School of Nuclear Science and Technology Research Institute of Iran. From these results, it is concluded that we can do experiments with this device using Ar as working gas all over the working days of year, and a good symmetry for measured dose around the device has been seen.

  1. Testing the Second-Order Factor Structure and Measurement Equivalence of the Wong and Law Emotional Intelligence Scale across Gender and Ethnicity

    Science.gov (United States)

    Whitman, Daniel S.; Van Rooy, David L.; Viswesvaran, Chockalingam; Kraus, Eyran

    2009-01-01

    The present study examined the measurement equivalence of a second-order factor model of emotional intelligence (EI). Using scores for 921 job applicants obtained during a personnel selection process, measurement equivalence of the Wong and Law Emotional Intelligence Scale (WLEIS) was tested across ethnic (Whites, Blacks, and Hispanics) and gender…

  2. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  3. SU-F-J-193: Efficient Dose Extinction Method for Water Equivalent Path Length (WEPL) of Real Tissue Samples for Validation of CT HU to Stopping Power Conversion

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, R; Baer, E; Jee, K; Sharp, G; Flanz, J; Lu, H [Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: For proton therapy, an accurate model of CT HU to relative stopping power (RSP) conversion is essential. In current practice, validation of these models relies solely on measurements of tissue substitutes with standard compositions. Validation based on real tissue samples would be much more direct and can address variations between patients. This study intends to develop an efficient and accurate system based on the concept of dose extinction to measure WEPL and retrieve RSP in biological tissue in large number of types. Methods: A broad AP proton beam delivering a spread out Bragg peak (SOBP) is used to irradiate the samples with a Matrixx detector positioned immediately below. A water tank was placed on top of the samples, with the water level controllable in sub-millimeter by a remotely controlled dosing pump. While gradually lowering the water level with beam on, the transmission dose was recorded at 1 frame/sec. The WEPL were determined as the difference between the known beam range of the delivered SOBP (80%) and the water level corresponding to 80% of measured dose profiles in time. A Gammex 467 phantom was used to test the system and various types of biological tissue was measured. Results: RSP for all Gammex inserts, expect the one made with lung-450 material (<2% error), were determined within ±0.5% error. Depends on the WEPL of investigated phantom, a measurement takes around 10 min, which can be accelerated by a faster pump. Conclusion: Based on the concept of dose extinction, a system was explored to measure WEPL efficiently and accurately for a large number of samples. This allows the validation of CT HU to stopping power conversions based on large number of samples and real tissues. It also allows the assessment of beam uncertainties due to variations over patients, which issue has never been sufficiently studied before.

  4. SU-F-J-193: Efficient Dose Extinction Method for Water Equivalent Path Length (WEPL) of Real Tissue Samples for Validation of CT HU to Stopping Power Conversion

    International Nuclear Information System (INIS)

    Zhang, R; Baer, E; Jee, K; Sharp, G; Flanz, J; Lu, H

    2016-01-01

    Purpose: For proton therapy, an accurate model of CT HU to relative stopping power (RSP) conversion is essential. In current practice, validation of these models relies solely on measurements of tissue substitutes with standard compositions. Validation based on real tissue samples would be much more direct and can address variations between patients. This study intends to develop an efficient and accurate system based on the concept of dose extinction to measure WEPL and retrieve RSP in biological tissue in large number of types. Methods: A broad AP proton beam delivering a spread out Bragg peak (SOBP) is used to irradiate the samples with a Matrixx detector positioned immediately below. A water tank was placed on top of the samples, with the water level controllable in sub-millimeter by a remotely controlled dosing pump. While gradually lowering the water level with beam on, the transmission dose was recorded at 1 frame/sec. The WEPL were determined as the difference between the known beam range of the delivered SOBP (80%) and the water level corresponding to 80% of measured dose profiles in time. A Gammex 467 phantom was used to test the system and various types of biological tissue was measured. Results: RSP for all Gammex inserts, expect the one made with lung-450 material (<2% error), were determined within ±0.5% error. Depends on the WEPL of investigated phantom, a measurement takes around 10 min, which can be accelerated by a faster pump. Conclusion: Based on the concept of dose extinction, a system was explored to measure WEPL efficiently and accurately for a large number of samples. This allows the validation of CT HU to stopping power conversions based on large number of samples and real tissues. It also allows the assessment of beam uncertainties due to variations over patients, which issue has never been sufficiently studied before.

  5. A New Measurement Equivalence Technique Based on Latent Class Regression as Compared with Multiple Indicators Multiple Causes.

    Science.gov (United States)

    Jamali, Jamshid; Ayatollahi, Seyyed Mohammad Taghi; Jafari, Peyman

    2016-06-01

    Measurement equivalence is an essential prerequisite for making valid comparisons in mental health questionnaires across groups. In most methods used for assessing measurement equivalence, which is known as Differential Item Functioning (DIF), latent variables are assumed to be continuous. To compare a new method called Latent Class Regression (LCR) designed for discrete latent variable with the multiple indicators multiple cause (MIMIC) as a continuous latent variable technique to assess the measurement equivalence of the 12-item General Health Questionnaire (GHQ-12), which is a cross deferent subgroup of Iranian nurses. A cross-sectional survey was conducted in 2014 among 771 nurses working in the hospitals of Fars and Bushehr provinces of southern Iran. To identify the Minor Psychiatric Disorders (MPD), the nurses completed self-report GHQ-12 questionnaires and sociodemographic questions. Two uniform-DIF detection methods, LCR and MIMIC, were applied for comparability when the GHQ-12 score was assumed to be discrete and continuous, respectively. The result of fitting LCR with 2 classes indicated that 27.4% of the nurses had MPD. Gender was identified as an influential factor of the level of MPD.LCR and MIMIC agree with detection of DIF and DIF-free items by gender, age, education and marital status in 83.3, 100.0, 91.7 and 83.3% cases, r