WorldWideScience

Sample records for dose assessment developments

  1. Development of a real-time radiological dose assessment system

    Energy Technology Data Exchange (ETDEWEB)

    Han, Moon Hee; Lee, Young Bok; Kim, Eun Han; Suh, Kyung Suk; Hwang, Won Tae; Choi, Young Gil

    1997-07-01

    A radiological dose assessment system named FADAS has been developed. This system is necessary to estimated the radiological consequences against a nuclear accident. Mass-consistent wind field module was adopted for the generation of wind field over the whole domain using the several measured wind data. Random-walk dispersion module is used for the calculation of the distribution of radionuclides in the atmosphere. And volume-equivalent numerical integration method has been developed for the assessment of external gamma exposure given from a randomly distributed radioactive materials and a dose data library has been made for rapid calculation. Field tracer experiments have been carried out for the purpose of analyzing the site-specific meteorological characteristics and increasing the accuracy of wind field generation and atmospheric dispersion module of FADAS. At first, field tracer experiment was carried out over flat terrain covered with rice fields using the gas samplers which were designed and manufactured by the staffs of KAERI. The sampled gas was analyzed using gas chromatograph. SODAR and airsonde were used to measure the upper wind. Korean emergency preparedness system CARE was integrated at Kori 4 nuclear power plants in 1995. One of the main functions of CARE is to estimate the radiological dose. The developed real-time dose assessment system FADAS was adopted in CARE as a tool for the radiological dose assessment. (author). 79 refs., 52 tabs., 94 figs.

  2. Development on Dose Assessment Model of Northeast Asia Nuclear Accident Simulator

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ju Yub; Kim, Ju Youl; Kim, Suk Hoon; Lee, Seung Hee; Yoon, Tae Bin [FNC Techology, Yongin (Korea, Republic of)

    2016-05-15

    In order to support the emergency response system, the simulator for overseas nuclear accident is under development including source-term estimation, atmospheric dispersion modeling and dose assessment. The simulator is named NANAS (Northeast Asia Nuclear Accident Simulator). For the source-term estimation, design characteristics of each reactor type should be reflected into the model. Since there are a lot of reactor types in neighboring countries, the representative reactors of China, Japan and Taiwan have been selected and the source-term estimation models for each reactor have been developed, respectively. For the atmospheric dispersion modeling, Lagrangian particle model will be integrated into the simulator for the long range dispersion modeling in Northeast Asia region. In this study, the dose assessment model has been developed considering external and internal exposure. The dose assessment model has been developed as a part of the overseas nuclear accidents simulator which is named NANAS. It addresses external and internal pathways including cloudshine, groundshine and inhalation. Also, it uses the output of atmospheric dispersion model (i.e. the average concentrations of radionuclides in air and ground) and various coefficients (e.g. dose conversion factor and breathing rate) as an input. Effective dose and thyroid dose for each grid in the Korean Peninsula region are printed out as a format of map projection and chart. Verification and validation on the dose assessment model will be conducted in further study by benchmarking with the measured data of Fukushima Daiichi Nuclear Accident.

  3. Development of environmental dose assessment system (EDAS) code of PC version

    Energy Technology Data Exchange (ETDEWEB)

    Taki, Mitsumasa; Kikuchi, Masamitsu; Kobayashi, Hideo; Yamaguchi, Takenori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-05-01

    A computer code (EDAS) was developed to assess the public dose for the safety assessment to get the license of nuclear reactor operation. This code system is used for the safety analysis of public around the nuclear reactor in normal operation and severe accident. This code was revised and composed for personal computer user according to the Nuclear Safety Guidelines reflected the ICRP1990 recommendation. These guidelines are revised by Nuclear Safety Commission on March, 2001, which are 'Weather analysis guideline for the safety assessment of nuclear power reactor', 'Public dose around the facility assessment guideline corresponding to the objective value for nuclear power light water reactor' and 'Public dose assessment guideline for safety review of nuclear power light water reactor'. This code has been already opened for public user by JAERI, and English version code and user manual are also prepared. This English version code is helpful for international cooperation concerning the nuclear safety assessment with JAERI. (author)

  4. Development of dose assessment code for accidental releases of activation products

    International Nuclear Information System (INIS)

    Noguchi, H.; Yokoyama, S.

    2000-01-01

    It is expected that activation products will be important radionuclides as well as tritium in the assessment of the public doses necessary for licensing of a future fusion reactor. In order to calculate the public doses due to the activation products released in cases of accidents, a code named ACUTAP (dose assessment code for ACUTe Activation Product releases) has been developed. Major characteristics of the code are as follows: (1) the transfer model reflects specific behavior of the activation products in the environment, (2) the doses are assessed based on ICRP dose models, (3) it is possible to calculate individual doses using annual meteorological data statistically according to the guide of the Nuclear Safety Commission of Japan, and (4) the code can calculate collective doses as well as individual doses. Individual doses are calculated for the following pathways: internal exposure by inhalation of activation products in a plume and those resuspended from the ground, external exposure from a plume (cloudshine), and external exposure from activation products deposited on the ground (groundshine). The inhalation in a plume and cloudshine pathways are included in the model for calculating collective doses. In addition to parent nuclides released from the facilities, progeny nuclides produced during the atmospheric dispersion are considered in calculating inhalation doses, and those during the deposition period in calculating groundshine doses. External doses from the cloudshine are calculated for 18 energy groups instead of individual energy of emitted gamma rays in order to save the computation time. Atmospheric concentrations are calculated using a Gaussian plume model with atmospheric dispersion parameters prescribed in the guide of the Nuclear Safety Commission of Japan. Data sets of parameters necessary for the dose assessment, such as internal dos coefficients, external dose rate conversion factors and half lives, are prepared for about 100 radionuclides

  5. Development of environmental dose assessment system (EDAS) code of PC version

    CERN Document Server

    Taki, M; Kobayashi, H; Yamaguchi, T

    2003-01-01

    A computer code (EDAS) was developed to assess the public dose for the safety assessment to get the license of nuclear reactor operation. This code system is used for the safety analysis of public around the nuclear reactor in normal operation and severe accident. This code was revised and composed for personal computer user according to the Nuclear Safety Guidelines reflected the ICRP1990 recommendation. These guidelines are revised by Nuclear Safety Commission on March, 2001, which are 'Weather analysis guideline for the safety assessment of nuclear power reactor', 'Public dose around the facility assessment guideline corresponding to the objective value for nuclear power light water reactor' and 'Public dose assessment guideline for safety review of nuclear power light water reactor'. This code has been already opened for public user by JAERI, and English version code and user manual are also prepared. This English version code is helpful for international cooperation concerning the nuclear safety assessme...

  6. Development of internal dose assessment procedure for workers in industries using raw materials containing naturally occurring radioactive materials

    International Nuclear Information System (INIS)

    Choi, Cheol Kyu; KIm, Yong Geon; Ji, Seung Woo; Kim, Kwang Pyo; Koo, Bon Cheol; Chang, Byung Uck

    2016-01-01

    It is necessary to assess radiation dose to workers due to inhalation of airborne particulates containing naturally occurring radioactive materials (NORM) to ensure radiological safety required by the Natural Radiation Safety Management Act. The objective of this study is to develop an internal dose assessment procedure for workers at industries using raw materials containing natural radionuclides. The dose assessment procedure was developed based on harmonization, accuracy, and proportionality. The procedure includes determination of dose assessment necessity, preliminary dose estimation, airborne particulate sampling and characterization, and detailed assessment of radiation dose. The developed dose assessment procedure is as follows. Radioactivity concentration criteria to determine dose assessment necessity are 10 Bq·g-1 for 40K and 1 Bq·g-1 for the other natural radionuclides. The preliminary dose estimation is performed using annual limit on intake (ALI). The estimated doses are classified into 3 groups (<0.1 mSv, 0.1-0.3 mSv, and >0.3 mSv). Air sampling methods are determined based on the dose estimates. Detailed dose assessment is performed using air sampling and particulate characterization. The final dose results are classified into 4 different levels (<0.1 mSv, 0.1-0.3 mSv, 0.3-1 mSv, and >1 mSv). Proper radiation protection measures are suggested according to the dose level. The developed dose assessment procedure was applied for NORM industries in Korea, including coal combustion, phosphate processing, and monazite handing facilities. The developed procedure provides consistent dose assessment results and contributes to the establishment of optimization of radiological protection in NORM industries

  7. Development of internal dose assessment procedure for workers in industries using raw materials containing naturally occurring radioactive materials

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Cheol Kyu; KIm, Yong Geon; Ji, Seung Woo; Kim, Kwang Pyo [College of Engineering, Kyung Hee University, Yongin (Korea, Republic of); Koo, Bon Cheol; Chang, Byung Uck [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-09-15

    It is necessary to assess radiation dose to workers due to inhalation of airborne particulates containing naturally occurring radioactive materials (NORM) to ensure radiological safety required by the Natural Radiation Safety Management Act. The objective of this study is to develop an internal dose assessment procedure for workers at industries using raw materials containing natural radionuclides. The dose assessment procedure was developed based on harmonization, accuracy, and proportionality. The procedure includes determination of dose assessment necessity, preliminary dose estimation, airborne particulate sampling and characterization, and detailed assessment of radiation dose. The developed dose assessment procedure is as follows. Radioactivity concentration criteria to determine dose assessment necessity are 10 Bq·g-1 for 40K and 1 Bq·g-1 for the other natural radionuclides. The preliminary dose estimation is performed using annual limit on intake (ALI). The estimated doses are classified into 3 groups (<0.1 mSv, 0.1-0.3 mSv, and >0.3 mSv). Air sampling methods are determined based on the dose estimates. Detailed dose assessment is performed using air sampling and particulate characterization. The final dose results are classified into 4 different levels (<0.1 mSv, 0.1-0.3 mSv, 0.3-1 mSv, and >1 mSv). Proper radiation protection measures are suggested according to the dose level. The developed dose assessment procedure was applied for NORM industries in Korea, including coal combustion, phosphate processing, and monazite handing facilities. The developed procedure provides consistent dose assessment results and contributes to the establishment of optimization of radiological protection in NORM industries.

  8. Development of a dose assessment computer code for the NPP severe accident

    International Nuclear Information System (INIS)

    Cheong, Jae Hak

    1993-02-01

    A real-time emergency dose assessment computer code called KEDA (KAIST NPP Emergency Dose Assessment) has been developed for the NPP severe accident. A new mathematical model which can calculate cloud shine has been developed and implemented in the code. KEDA considers the specific Korean situations(complex topography, orientals' thyroid metabolism, continuous washout, etc.), and provides functions of dose-monitoring and automatic decision-making. To verify the code results, KEDA has been compared with an NRC officially certified code, RASCAL, for eight hypertical accident scenarios. Through the comparison, KEDA has been proved to provide reasonable results. Qualitative sensitivity analysis also the been performed for potentially important six input parameters, and the trends of the dose v.s. down-wind distance curve have been analyzed comparing with the physical phenomena occurred in the real atmosphere. The source term and meteorological conditions are turned out to be the most important input parameters. KEDA also has been applied to simulate Kori site and a hyperthetical accident with semi-real meteorological data has been simulated and analyzed

  9. Development of Landscape Dose Factors for dose assessments in SR-Can

    Energy Technology Data Exchange (ETDEWEB)

    Avila, Rodolfo; Ekstroem, Per-Anders [Facilia AB, Bromma (Sweden); Kautsky, Ulrik [Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden)

    2006-08-15

    In previous safety assessments Ecosystem Dose Factors (EDFs), were derived from estimates of doses to the most exposed group resulting from constant unit radionuclide release rates over 10,000 years to various ecosystem types, e.g. mires, agricultural lands, lakes and marine ecosystems. A number of limitations of the EDF approach have been identified. The objectives of this report is to further develop the EDF approach, in order to resolve the identified limitations, and to use the improved approach for deriving Dose Conversion Factors for use in the SR-Can risk assessments. The Dose Conversion Factors derived in this report are named Landscape Dose Factors (LDFs). It involves modelling the fate of the radionuclides in the whole landscape, which develops from a sea to a inland situation during 20,000 years. Both candidate sites studies in SR-Can, Forsmark and Laxemar, are included in the study. As a basis for the modelling, the period starting at the beginning of the last interglacial (8,000 BC) is used, over which releases from a hypothetical repository were assumed to take place. For the present temperate period, the overall development of the biosphere at each site is outlined in a 1,000 year perspective and beyond, essentially based on the ongoing shoreline displacement and the understanding on the impact this has on the biosphere. The past development, i.e. from deglaciation to the present time, is inferred from geological records and associated reconstructions of the shore-line. For each time step of 1,000 years, the landscape at the site is described as a number of interconnected biosphere objects constituting an integrated landscape model of each site. The water fluxes through the objects were estimated from the average run-off at the site, the areas of the objects and their associated catchment areas. Radionuclides in both dissolved and particulate forms were considered in the transport calculations. The transformation between ecosystems was modelled as

  10. Assessment of doses to non-human biota: Review of developments and demonstration assessment for Olkiluoto repository

    International Nuclear Information System (INIS)

    Smith, K.; Robinson, C.

    2006-12-01

    This report provides a summary of work commissioned by Posiva Oy and undertaken by Enviros Consulting Ltd to support the development of a strategy for the assessment of environmental impacts from ionising radiation associated with the Olkiluoto waste repository, Finland, as part of the development of the Posiva Safety Case Portfolio. This project included a review of the development of international policies and standards related to protection of biota from the effects of ionizing radiation and of biota assessment methodologies, paying particular attention to those that have been applied to waste repository performance assessments. On the basis of this review, recommendations were developed on the most appropriate methodology to apply in order to assess the impact of radioactive releases from the planned spent fuel repository in Olkiluoto. A test-case was developed, in collaboration with staff from Posiva and Facilia AB, and an assessment was performed. The results and experience of which were analysed and summarised to develop recommendations for a future strategy. The test case highlighted some significant data gaps related to the assessment of impacts to both generic biota types and to interest species. In particular, concentration ratios for generic carnivorous mammals and migratory species such as moose that may consume food from multiple ecosystems and dose conversion factors for large burrowing (i.e. hibernating) mammals. However, in general terms, the dose rates predicted for all organism types were several orders of magnitude below those at which population effects would be expected to be observed and those at which effects on the individual may be anticipated. There would therefore be scope for simplifying the approach applied, although there would be value in performing a sensitivity analysis to ensure that the simplification is applied appropriately. There would also be value in ensuring consistency of the developing approach for non-human biota with

  11. Assessment of doses to non-human biota: Review of developments and demonstration assessment for Olkiluoto repository

    Energy Technology Data Exchange (ETDEWEB)

    Smith, K. [Carol Robinson Enviros Consulting Ltd, Edinburgh (United Kingdom)

    2006-12-15

    This report provides a summary of work commissioned by Posiva Oy and undertaken by Enviros Consulting Ltd to support the development of a strategy for the assessment of environmental impacts from ionising radiation associated with the Olkiluoto waste repository, Finland, as part of the development of the Posiva Safety Case Portfolio. This project included a review of the development of international policies and standards related to protection of biota from the effects of ionizing radiation and of biota assessment methodologies, paying particular attention to those that have been applied to waste repository performance assessments. On the basis of this review, recommendations were developed on the most appropriate methodology to apply in order to assess the impact of radioactive releases from the planned spent fuel repository in Olkiluoto. A test-case was developed, in collaboration with staff from Posiva and Facilia AB, and an assessment was performed. The results and experience of which were analysed and summarised to develop recommendations for a future strategy. The test case highlighted some significant data gaps related to the assessment of impacts to both generic biota types and to interest species. In particular, concentration ratios for generic carnivorous mammals and migratory species such as moose that may consume food from multiple ecosystems and dose conversion factors for large burrowing (i.e. hibernating) mammals. However, in general terms, the dose rates predicted for all organism types were several orders of magnitude below those at which population effects would be expected to be observed and those at which effects on the individual may be anticipated. There would therefore be scope for simplifying the approach applied, although there would be value in performing a sensitivity analysis to ensure that the simplification is applied appropriately. There would also be value in ensuring consistency of the developing approach for non-human biota with

  12. European project for developing general guidelines for harmonising internal dose assessment procedures (IDEAS)

    International Nuclear Information System (INIS)

    Andrasi, A.; Bailey, M.; Puncher, M.; Berkovski, V.; Eric Blanchardon, E.; Jourdain, J.-R.; Carlo-Maria Castellani, C.-M.; Doerfel, H.; Christian Hurtgen, Ch.; Le Guen, B.

    2003-01-01

    Several international intercomparison exercises on intake and internal dose assessments from monitoring data led to the conclusion that the results calculated by different participants varied significantly mainly because of the wide variety of methods and assumptions applied in the assessment procedure. Based on these experiences the need for harmonisation of the procedures has been formulated as an EU research project under the 5 th Framework Programme (2001-2005), with the aim of developing general guidelines for standardising assessments of intakes and internal doses. In the IDEAS project eight institutions from seven European countries are participating using inputs also from internal dosimetry professionals from across Europe to ensure broad consensus in the outcome of the project. The IDEAS project is explained

  13. Consultative exercise on dose assessments.

    Science.gov (United States)

    Bridges, B A; Parker, T; Simmonds, J R; Sumner, D

    2001-06-01

    A summary is given of a meeting held at Sussex University, UK, in October 2000, which allowed the exchange of ideas on methods of assessment of dose to the public arising from potential authorised radioactive discharges from nuclear sites in the UK. Representatives of groups with an interest in dose assessments were invited, and hence the meeting was called the Consultative Exercise on Dose Assessments (CEDA). Although initiated and funded by the Food Standards Agency, its organisation, and the writing of the report, were overseen by an independent Chairman and Steering Group. The report contains recommendations for improvement in co-ordination between different agencies involved in assessments, on method development and on the presentation of data on assessments. These have been prepared by the Steering Group, and will be taken forward by the Food Standards Agency and other agencies in the UK. The recommendations are included in this memorandum.

  14. Development of radiation dose assessment system for radiation accident (RADARAC)

    International Nuclear Information System (INIS)

    Takahashi, Fumiaki; Shigemori, Yuji; Seki, Akiyuki

    2009-07-01

    The possibility of radiation accident is very rare, but cannot be regarded as zero. Medical treatments are quite essential for a heavily exposed person in an occurrence of a radiation accident. Radiation dose distribution in a human body is useful information to carry out effectively the medical treatments. A radiation transport calculation utilizing the Monte Carlo method has an advantageous in the analysis of radiation dose inside of the body, which cannot be measured. An input file, which describes models for the accident condition and quantities of interest, should be prepared to execute the radiation transport calculation. Since the accident situation, however, cannot be prospected, many complicated procedures are needed to make effectively the input file soon after the occurrence of the accident. In addition, the calculated doses are to be given in output files, which usually include much information concerning the radiation transport calculation. Thus, Radiation Dose Assessment system for Radiation Accident (RADARAC) was developed to derive effectively radiation dose by using the MCNPX or MCNP code. RADARAC mainly consists of two parts. One part is RADARAC - INPUT, which involves three programs. A user can interactively set up necessary resources to make input files for the codes, with graphical user interfaces in a personnel computer. The input file includes information concerning the geometric structure of the radiation source and the exposed person, emission of radiations during the accident, physical quantities of interest and so on. The other part is RADARAC - DOSE, which has one program. The results of radiation doses can be effectively indicated with numerical tables, graphs and color figures visibly depicting dose distribution by using this program. These results are obtained from the outputs of the radiation transport calculations. It is confirmed that the system can effectively make input files with a few thousand lines and indicate more than 20

  15. Development of Computational Procedure for Assessment of Patient Dose in Multi-Detector Computed Tomography

    International Nuclear Information System (INIS)

    Park, Dong Wook

    2007-02-01

    Technological development to improve the quality and speed with which images are obtained have fostered the growth of frequency and collective effective dose of CT examination. Especially, High-dose x-ray technique of CT has increased in the concern of patient dose. However CTDI and DLP in CT dosimetry leaves something to be desired to evaluate patient dose. And even though the evaluation of effective dose in CT practice is required for comparison with other radiography, it's not sufficient to show any estimation because it's not for medical purpose. Therefore the calculation of effective dose in CT procedure is needed for that purpose. However modelling uncertainties will be due to insufficient information from manufacturing tolerances. Therefore the purpose of this work is development of computational procedure for assessment of patient dose through the experiment for getting essential information in MDCT. In order to obtain exact absorbed dose, normalization factors must be created to relate simulated dose values with CTDI air measurement. The normalization factors applied to the calculation of CTDI 100 using axial scanning and organ effective dose using helical scanning. The calculation of helical scanning was compared with the experiment of Groves et al.(2004). The result has a about factor 2 of the experiment. It seems because AEC is not simulated. In several studies, when AEC applied to a CT examination, approximately 20-30% dose reduction was appeared. Therefore the study of AEC simulation should be added and modified

  16. IAEA/IDEAS intercomparison exercise on internal dose assessment

    International Nuclear Information System (INIS)

    Doerfel, H.; Andrasi, A.; Cruz-Suarez, R.; Castellani, C. M.; Hurtgen, C.; Marsh, J.; Zeger, J.

    2007-01-01

    An Internet based intercomparison exercise on assessment of occupational exposure due to intakes of radionuclides has been performed to check the applicability of the 'General Guidelines for the Assessment of Internal Dose from Monitoring Data' developed by the IDEAS group. There were six intake cases presented on the Internet and 81 participants worldwide reported solutions to these cases. Results of the exercise indicate that the guidelines have a positive influence on the methodologies applied for dose assessments and, if correctly applied, improve the harmonisation of assessed doses. (authors)

  17. The development of a methodology to assess population doses from multiple sources and exposure pathways of radioactivity

    International Nuclear Information System (INIS)

    Hancox, J.; Stansby, S.; Thorne, M.

    2002-01-01

    The Environment Agency (EA) has new duties in accordance with the Basic Safety Standards Directive under which it is required to ensure that doses to individuals received from exposure to anthropogenic sources of radioactivity are within defined limits. In order to assess compliance with these requirements, the EA needs to assess the doses to members of the most highly exposed population groups ('critical' groups) from all relevant potential sources of anthropogenic radioactivity and all relevant potential exposure pathways to such radioactivity. The EA has identified a need to develop a methodology for the retrospective assessment of effective doses from multiple sources of radioactive materials and exposure pathways associated with those sources. Under contract to the EA, AEA Technology has undertaken the development of a suitable methodology as part of EA R and D Project P3-070. The methodology developed under this research project has been designed to support the EA in meeting its obligations under the Euratom Basic Safety Standards Directive and is consistent with UK and international approaches to radiation dosimetry and radiological protection. The development and trial application of the methodology is described in this report

  18. Assessment of exposure dose to workers in virtual decommissioning environments

    International Nuclear Information System (INIS)

    Jeong, KwanSeong; Moon, JeiKwon; Choi, ByungSeon; Hyun, Dongjun; Lee, Jonghwan; Kim, Ikjune; Kim, GeunHo; Seo, JaeSeok

    2014-01-01

    This paper is intended to suggest the method analyze and assess the exposure dose to workers in virtual decommissioning environments. To simulate a lot of decommissioning scenarios, decommissioning environments were designed in virtual reality. To simulate and assess the exposure dose to workers, human model also was designed in virtual environments. These virtual decommissioning environments made it possible to real-time simulate and assess the exposure dose to workers. This work was to be able to simulate scenarios of decommissioning so that exposure dose to workers could be measured and assessed. To establish the plan of exposure dose to workers during decommissioning of nuclear facilities before decommissioning activities are accomplished, the method of simulation assessment was developed in virtual radiological environments. But this work was developed as a tool of simulation for single subject mode. Afterwards, the simulation environment for multi-subjects mode will be upgraded by simultaneous modules with networking environments. Then the much more practical method will be developed by changing number of workers and duration of time under any circumstances of decommissioning

  19. Assessment of exposure dose to workers in virtual decommissioning environments

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, KwanSeong; Moon, JeiKwon; Choi, ByungSeon; Hyun, Dongjun; Lee, Jonghwan; Kim, Ikjune; Kim, GeunHo; Seo, JaeSeok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    This paper is intended to suggest the method analyze and assess the exposure dose to workers in virtual decommissioning environments. To simulate a lot of decommissioning scenarios, decommissioning environments were designed in virtual reality. To simulate and assess the exposure dose to workers, human model also was designed in virtual environments. These virtual decommissioning environments made it possible to real-time simulate and assess the exposure dose to workers. This work was to be able to simulate scenarios of decommissioning so that exposure dose to workers could be measured and assessed. To establish the plan of exposure dose to workers during decommissioning of nuclear facilities before decommissioning activities are accomplished, the method of simulation assessment was developed in virtual radiological environments. But this work was developed as a tool of simulation for single subject mode. Afterwards, the simulation environment for multi-subjects mode will be upgraded by simultaneous modules with networking environments. Then the much more practical method will be developed by changing number of workers and duration of time under any circumstances of decommissioning.

  20. Development of low-dose protocols for thin-section CT assessment of cystic fibrosis in pediatric patients.

    LENUS (Irish Health Repository)

    O'Connor, Owen J

    2010-12-01

    To develop low-dose thin-section computed tomographic (CT) protocols for assessment of cystic fibrosis (CF) in pediatric patients and determine the clinical usefulness thereof compared with chest radiography.

  1. Enjebi Island dose assessment

    International Nuclear Information System (INIS)

    Robison, W.L.; Conrado, C.L.; Phillips, W.A.

    1987-07-01

    We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and 137 Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral whole-body dose equivalents are 3.5 rem, 5.1 rem, and 6.2 rem, respectively. Bone-marrow dose equivalents are only slightly higher than the whole-body estimates in each case. The bone-surface cells (endosteal cells) receive the highest dose, but they are a less sensitive cell population and are less sensitive to fatal cancer induction than whole body and bone marrow. The effective dose equivalents for 30, 50, and 70 y are 3.6 rem, 5.3 rem, and 6.6 rem, respectively. 79 refs., 17 figs., 24 tabs

  2. Dose assessment in radiological accidents

    International Nuclear Information System (INIS)

    Donkor, S.

    2013-04-01

    The applications of ionizing radiation bring many benefits to humankind, ranging from power generation to uses in medicine, industry and agriculture. Facilities that use radiation source require special care in the design and operation of equipment to prevent radiation injury to workers or to the public. Despite considerable development of radiation safety, radiation accidents do happen. The purpose of this study is therefore to discuss how to assess doses to people who will be exposed to a range of internal and external radiation sources in the event of radiological accidents. This will go a long way to complement their medical assessment thereby helping to plan their treatment. Three radiological accidents were reviewed to learn about the causes of those accidents and the recommendations that were put in place to prevent recurrence of such accidents. Various types of dose assessment methods were discussed.(au)

  3. A review of occupational dose assessment uncertainties and approaches

    International Nuclear Information System (INIS)

    Anderson, R. W.

    2004-01-01

    The Radiological Protection Practitioner (RPP) will spend a considerable proportion of his time predicting or assessing retrospective radiation exposures to occupational personnel for different purposes. The assessments can be for a variety of purposes, such as to predict doses for occupational dose control, or project design purposes or to make retrospective estimates for the dose record, or account for dosemeters which have been lost or damaged. There are other less frequent occasions when dose assessment will be required such as to support legal cases and compensation claims and to provide the detailed dose information for epidemiological studies. It is important that the level of detail, justification and supporting evidence in the dose assessment is suitable for the requirements. So for instance, day to day operational dose assessments often rely mainly on the knowledge of the RPP in discussion with operators whilst at the other end of the spectrum a historical dose assessment for a legal case will require substantial research and supporting evidence for the estimate to withstand forensic challenge. The robustness of the assessment will depend on many factors including a knowledge of the work activities, the radiation dose uptake and field characteristics; all of which are affected by factors such as the time elapsed, the memory of operators and the dosemeters employed. This paper reviews the various options and uncertainties in dose assessments ranging from use of personal dosimetry results to the development of upper bound assessments. The level of assessment, the extent of research and the evidence adduced should then be appropriate to the end use of the estimate. (Author)

  4. Development of dose assessment code for release of tritium during normal operation of nuclear power plants

    International Nuclear Information System (INIS)

    Duran, J.; Malatova, I.

    2009-01-01

    A computer code PTM H TO has been developed to assess tritium doses to the general public. The code enables to simulate the behavior of tritium in the environment released into the atmosphere under normal operation of nuclear power plants. Code can calculate the doses for the three chemical and physical forms: tritium gas (HT), tritiated water vapor and water drops (HTO). The models in this code consist of the tritium transfer model including oxidation of HT to HTO and reemission of HTO from soil to the atmosphere, and the dose calculation model

  5. Technology Assessment and Roadmap for the Emergency Radiation Dose Assessment Program

    International Nuclear Information System (INIS)

    Turteltaub, K W; Hartman-Siantar, C; Easterly, C; Blakely, W

    2005-01-01

    A Joint Interagency Working Group (JIWG) under the auspices of the Department of Homeland Security Office of Research and Development conducted a technology assessment of emergency radiological dose assessment capabilities as part of the overall need for rapid emergency medical response in the event of a radiological terrorist event in the United States. The goal of the evaluation is to identify gaps and recommend general research and development needs to better prepare the Country for mitigating the effects of such an event. Given the capabilities and roles for responding to a radiological event extend across many agencies, a consensus of gaps and suggested development plans was a major goal of this evaluation and road-mapping effort. The working group consisted of experts representing the Departments of Homeland Security, Health and Human Services (Centers for Disease Control and the National Institutes of Health), Food and Drug Administration, Department of Defense and the Department of Energy's National Laboratories (see appendix A for participants). The specific goals of this Technology Assessment and Roadmap were to: (1) Describe the general context for deployment of emergency radiation dose assessment tools following terrorist use of a radiological or nuclear device; (2) Assess current and emerging dose assessment technologies; and (3) Put forward a consensus high-level technology roadmap for interagency research and development in this area. This report provides a summary of the consensus of needs, gaps and recommendations for a research program in the area of radiation dosimetry for early response, followed by a summary of the technologies available and on the near-term horizon. We then present a roadmap for a research program to bring present and emerging near-term technologies to bear on the gaps in radiation dose assessment and triage. Finally we present detailed supporting discussion on the nature of the threats we considered, the status of technology

  6. Technology Assessment and Roadmap for the Emergency Radiation Dose Assessment Program

    Energy Technology Data Exchange (ETDEWEB)

    Turteltaub, K W; Hartman-Siantar, C; Easterly, C; Blakely, W

    2005-10-03

    A Joint Interagency Working Group (JIWG) under the auspices of the Department of Homeland Security Office of Research and Development conducted a technology assessment of emergency radiological dose assessment capabilities as part of the overall need for rapid emergency medical response in the event of a radiological terrorist event in the United States. The goal of the evaluation is to identify gaps and recommend general research and development needs to better prepare the Country for mitigating the effects of such an event. Given the capabilities and roles for responding to a radiological event extend across many agencies, a consensus of gaps and suggested development plans was a major goal of this evaluation and road-mapping effort. The working group consisted of experts representing the Departments of Homeland Security, Health and Human Services (Centers for Disease Control and the National Institutes of Health), Food and Drug Administration, Department of Defense and the Department of Energy's National Laboratories (see appendix A for participants). The specific goals of this Technology Assessment and Roadmap were to: (1) Describe the general context for deployment of emergency radiation dose assessment tools following terrorist use of a radiological or nuclear device; (2) Assess current and emerging dose assessment technologies; and (3) Put forward a consensus high-level technology roadmap for interagency research and development in this area. This report provides a summary of the consensus of needs, gaps and recommendations for a research program in the area of radiation dosimetry for early response, followed by a summary of the technologies available and on the near-term horizon. We then present a roadmap for a research program to bring present and emerging near-term technologies to bear on the gaps in radiation dose assessment and triage. Finally we present detailed supporting discussion on the nature of the threats we considered, the status of

  7. Biosphere Modeling for the Dose Assessment of a HLW Repository: Development of ACBIO

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Youn Myoung; Hwang, Yong Soo; Kang, Chul Hyung

    2006-01-15

    For the purpose of evaluating a dose rate to an individual due to a long-term release of nuclides from a HLW repository, a biosphere assessment model and an implemented code, ACBIO, based on the BIOMASS methodology have been developed by utilizing AMBER, a general compartment modeling tool. To demonstrate its practicability and usability as well as to observe the sensitivity of the compartment scheme, the concentration, the activity in the compartments as well as the annual flux between the compartments at their peak values, were calculated and investigated. For each case when changing the structure of the compartments and GBIs as well as varying selected input Kd values, all of which seem very important among the others, the dose rate per nuclide release rate is calculated separately and analyzed. From the maximum dose rates, the flux to dose conversion factors for each nuclide were derived, which are used for converting the nuclide release rate appearing from the geosphere through various GBIs to dose rates (Sv/y) for an individual in a critical group. It has also been observed that the compartment scheme, the identification of a possible exposure group and the GBIs could all be highly sensitive to the final consequences in a biosphere modeling.

  8. Biosphere Modeling for the Dose Assessment of a HLW Repository: Development of ACBIO

    International Nuclear Information System (INIS)

    Lee, Youn Myoung; Hwang, Yong Soo; Kang, Chul Hyung

    2006-01-01

    For the purpose of evaluating a dose rate to an individual due to a long-term release of nuclides from a HLW repository, a biosphere assessment model and an implemented code, ACBIO, based on the BIOMASS methodology have been developed by utilizing AMBER, a general compartment modeling tool. To demonstrate its practicability and usability as well as to observe the sensitivity of the compartment scheme, the concentration, the activity in the compartments as well as the annual flux between the compartments at their peak values, were calculated and investigated. For each case when changing the structure of the compartments and GBIs as well as varying selected input Kd values, all of which seem very important among the others, the dose rate per nuclide release rate is calculated separately and analyzed. From the maximum dose rates, the flux to dose conversion factors for each nuclide were derived, which are used for converting the nuclide release rate appearing from the geosphere through various GBIs to dose rates (Sv/y) for an individual in a critical group. It has also been observed that the compartment scheme, the identification of a possible exposure group and the GBIs could all be highly sensitive to the final consequences in a biosphere modeling

  9. Development of the model MAAP5-DOSE for dose analysis in Cofrentes NPP

    International Nuclear Information System (INIS)

    Gonzalez, C.; Diaz, P.; Ibanez, L.; Lamela, B.; Serrano, C.

    2013-01-01

    Iberdrola Ingenieria y Construccion has developed a model of Cofrentes NPP with code MAAP5-DOSE in order to be able to assess in realistic conditions the the expected dose in points and radiological consequences of severe accident of local action.

  10. Development of a dosimeter for high doses assessment based on Alanine/EPR

    International Nuclear Information System (INIS)

    Galante, O.L.; Rodrigues, O. Jr.; Campos, L.L.

    2000-01-01

    The increasing use of radiation sources of high activity for industrial and medical applications becomes important the research and the development of detectors and dosimetric methods for quality control of the applied doses. This work presents the current stage of the research at IPEN/CNEN-SP that has as objective the development of a standard dosimetric system for high doses assessment based on the alanine as radiation detector and electron paramagnetic resonance (EPR) as measurement technique. The developed system consists of the cylindrical container built in polyethylene of high density and the detector element based on DL-alanine commercially available. For the detector preparation different binding materials such as paraffin and acetate polyvinyl solution (pva) and also the use of a polyethylene tube of low density with 3.2 mm of external diameter, 2 mm of internal diameter and 30 mm of length were tested to provide the easier preparation method and the most sensitive detector. For the alanine + paraffin detector it was used 80% of alanine and 20% of paraffin, for the alanine + pva detector it was used 70% of alanine and 30% of pva solution, and pure alanine was encapsulated, compacted and sealed in the case of the polyethylene tube. The obtained results with respect to handling, packing and construction easiness showed that the polyethylene tube presents all characteristics to obtain of a good detector element. The validation of the dosimetric system was carried out with gamma radiation of the cobalt-60 with doses in the range between 0.2 Gy to 200 kGy. Type tests such as fading, lowest detection limit, reproducibility and energy dependence of the sign EPR were performed. All measurements were carried out at room temperature using a spectrometer of electron paramagnetic resonance (EPR) Bruker model MXE. Taking into account the results obtained: linearity of the EPR signal between 10 Gy and 50 kGy, reproducibility better than 3%, low fading associated with

  11. Program for rapid dose assessment in criticality accident, RADAPAS

    International Nuclear Information System (INIS)

    Takahashi, Fumiaki

    2006-09-01

    In a criticality accident, a person near fissile material can receive extremely high dose which can cause acute health effect. For such a case, medical treatment should be carried out for the exposed person, according to severity of the exposure. Then, radiation dose should be rapidly assessed soon after an outbreak of an accident. Dose assessment based upon the quantity of induced 24 Na in human body through neutron exposure is expected as one of useful dosimetry techniques in a criticality accident. A dose assessment program, called RADAPAS (RApid Dose Assessment Program from Activated Sodium in Criticality Accidents), was therefore developed to assess rapidly radiation dose to exposed persons from activity of induced 24 Na. RADAPAS consists of two parts; one is a database part and the other is a part for execution of dose calculation. The database contains data compendiums of energy spectra and dose conversion coefficients from specific activity of 24 Na induced in human body, which had been derived in a previous analysis using Monte Carlo calculation code. Information for criticality configuration or characteristics of radiation in the accident field is to be interactively given with interface displays in the dose calculation. RADAPAS can rapidly derive radiation dose to the exposed person from the given information and measured 24 Na specific activity by using the conversion coefficient in database. This report describes data for dose conversions and dose calculation in RADAPAS and explains how to use the program. (author)

  12. Non-human biota dose assessment. Sensitivity analysis and knowledge quality assessment

    International Nuclear Information System (INIS)

    Smith, K.; Robinson, C.; Jackson, D.; La Cruz, I. de; Zinger, I.; Avila, R.

    2010-10-01

    This report provides a summary of a programme of work, commissioned within the BIOPROTA collaborative forum, to assess the quantitative and qualitative elements of uncertainty associated with biota dose assessment of potential impacts of long-term releases from geological disposal facilities (GDF). Quantitative and qualitative aspects of uncertainty were determined through sensitivity and knowledge quality assessments, respectively. Both assessments focused on default assessment parameters within the ERICA assessment approach. The sensitivity analysis was conducted within the EIKOS sensitivity analysis software tool and was run in both generic and test case modes. The knowledge quality assessment involved development of a questionnaire around the ERICA assessment approach, which was distributed to a range of experts in the fields of non-human biota dose assessment and radioactive waste disposal assessments. Combined, these assessments enabled critical model features and parameters that are both sensitive (i.e. have a large influence on model output) and of low knowledge quality to be identified for each of the three test cases. The output of this project is intended to provide information on those parameters that may need to be considered in more detail for prospective site-specific biota dose assessments for GDFs. Such information should help users to enhance the quality of their assessments and build greater confidence in the results. (orig.)

  13. Occupational dose assessment and national dose registry system in Iran

    International Nuclear Information System (INIS)

    Jafari-Zadeh, M.; Nazeri, F.; Hosseini-Pooya, S. M.; Taheri, M.; Gheshlaghi, F.; Kardan, M. R.; Babakhani, A.; Rastkhah, N.; Yousefi-Nejad, F.; Darabi, M.; Oruji, T.; Gholamali-Zadeh, Z.; Karimi-Diba, J.; Kazemi-Movahed, A. A.; Dashti-Pour, M. R.; Enferadi, A.; Jahanbakhshian, M. H.; Sadegh-Khani, M. R.

    2011-01-01

    This report presents status of external and internal dose assessment of workers and introducing the structure of National Dose Registry System of Iran (NDRSI). As well as types of individual dosemeters in use, techniques for internal dose assessment are presented. Results obtained from the International Atomic Energy Agency intercomparison programme on measurement of personal dose equivalent H p (10) and consistency of the measured doses with the delivered doses are shown. Also, implementation of dosimetry standards, establishment of quality management system, authorisation and approval procedure of dosimetry service providers are discussed. (authors)

  14. Inhalation dose assessment for Maralinga and Emu

    International Nuclear Information System (INIS)

    Johnston, P.N.; Lokan, K.H.; Williams, G.A.

    1990-01-01

    Dose assessments for the inhalation of artificial radionuclides are presented for all types of contaminated areas at Maralinga and Emu. These enable Committed Effective Dose Equivalent (CEDE), to be estimated by scaling at any area of interest where activity concentrations are known. In the case of Aborigines, these dose are estimated assuming respirable dust loadings of 1 mg/m 3 for adults and 1.5 mg/m 3 for children and infants. Details of the calculations are presented in the appendix. The model of the respiratory system used in this assessment is that described in Interantional Commission on Radiological Protection (ICRP) Publication 30 (ICRP, 1979a). With the exception of Kuli, which is contaminated with uranium, at all other sites it is only the inhalation of plutonium and americium that contributes significantly to the dose, and of these 239 Pu is the largest contributor. Therefore, considering the long half lives of the radionuclides concerned, it appears that the inhalation problems highlighted by this dose assessment will not diminish significantly within any reasonable period of time and hence management strategies must be developed to deal with such problems. 32 refs., 5 tabs., 1 fig

  15. Calculational Tool for Skin Contamination Dose Assessment

    CERN Document Server

    Hill, R L

    2002-01-01

    Spreadsheet calculational tool was developed to automate the calculations preformed for dose assessment of skin contamination. This document reports on the design and testing of the spreadsheet calculational tool.

  16. Assessing doses of radiotherapy with the risk of developing cancer in the head and neck

    International Nuclear Information System (INIS)

    Yu, Cheng-Ching; Hsu, Fang-Yuh; Yu, Wan-Hsuan; Liu, Mu-Tai; Huang, Sheng-Shien

    2011-01-01

    Radiation is known to be a major cause of cancer in normal tissue. After treatment with radiotherapy, for young patients or the patients can survive for a long time, the radiation-induced cancer risk is noteworthy. This research investigated the dose delivered by the treatment of intensity modulated radiation therapy (IMRT) for head and neck cancer, such as NPC and oral cancer, and assessed the risk of developing radiation-induced secondary cancer in non-targeted normal tissues. A Rando phantom was used to simulate a patient with NPC or oral cancer, and thermoluminescent dosimeter (TLD) chips were placed inside the phantom to estimate the doses delivered by IMRT. In summary, the risks to patients with NPC was somewhat higher than for those with oral cancer, because the region of the PTV was lower, requiring larger field sizes be used for cases of NPC. The smaller the field size used, the less the risk was of developing secondary cancer. In addition, the higher the value of MU used, the higher the dose delivered to normal tissues was. The risk of radiation-induced secondary cancer was proportional to the delivered dose.

  17. Interactive Rapid Dose Assessment Model (IRDAM): user's guide

    International Nuclear Information System (INIS)

    Poeton, R.W.; Moeller, M.P.; Laughlin, G.J.; Desrosiers, A.E.

    1983-05-01

    As part of the continuing emphasis on emergency preparedness the US Nuclear Regulatory Commission (NRC) sponsored the development of a rapid dose assessment system by Pacific Northwest Laboratory (PNL). This system, the Interactive Rapid Dose Assessment Model (IRDAM) is a micro-computer based program for rapidly assessing the radiological impact of accidents at nuclear power plants. This User's Guide provides instruction in the setup and operation of the equipment necessary to run IRDAM. Instructions are also given on how to load the magnetic disks and access the interactive part of the program. Two other companion volumes to this one provide additional information on IRDAM. Reactor Accident Assessment Methods (NUREG/CR-3012, Volume 2) describes the technical bases for IRDAM including methods, models and assumptions used in calculations. Scenarios for Comparing Dose Assessment Models (NUREG/CR-3012, Volume 3) provides the results of calculations made by IRDAM and other models for specific accident scenarios

  18. Internal dose assessment in radiation accidents

    International Nuclear Information System (INIS)

    Toohey, R.E.

    2003-01-01

    Although numerous models have been developed for occupational and medical internal dosimetry, they may not be applicable to an accident situation. Published dose coefficients relate effective dose to intake, but if acute deterministic effects are possible, effective dose is not a useful parameter. Consequently, dose rates to the organs of interest need to be computed from first principles. Standard bioassay methods may be used to assess body contents, but, again, the standard models for bioassay interpretation may not be applicable because of the circumstances of the accident and the prompt initiation of decorporation therapy. Examples of modifications to the standard methodologies include adjustment of biological half-times under therapy, such as in the Goiania accident, and the same effect, complicated by continued input from contaminated wounds, in the Hanford 241 Am accident. (author)

  19. The MESORAD dose assessment model: Computer code

    International Nuclear Information System (INIS)

    Ramsdell, J.V.; Athey, G.F.; Bander, T.J.; Scherpelz, R.I.

    1988-10-01

    MESORAD is a dose equivalent model for emergency response applications that is designed to be run on minicomputers. It has been developed by the Pacific Northwest Laboratory for use as part of the Intermediate Dose Assessment System in the US Nuclear Regulatory Commission Operations Center in Washington, DC, and the Emergency Management System in the US Department of Energy Unified Dose Assessment Center in Richland, Washington. This volume describes the MESORAD computer code and contains a listing of the code. The technical basis for MESORAD is described in the first volume of this report (Scherpelz et al. 1986). A third volume of the documentation planned. That volume will contain utility programs and input and output files that can be used to check the implementation of MESORAD. 18 figs., 4 tabs

  20. Bio-indicators for radiation dose assessment

    International Nuclear Information System (INIS)

    Trivedi, A.

    1990-12-01

    In nuclear facilities, such as Chalk River Laboratories, dose to the atomic radiation workers (ARWs) is assessed routinely by using physical dosimeters and bioassay procedures in accordance with regulatory recommendations. However, these procedures may be insufficient in some circumstances, e.g., in cases where the reading of the physical dosimeters is questioned, in cases of radiation accidents where the person(s) in question was not wearing a dosimeter, or in the event of a radiation emergency when an exposure above the dose limits is possible. The desirability of being able to assess radiation dose on the basis of radio-biological effects has prompted the Dosimetric Research Branch to investigate the suitability of biological devices and techniques that could be used for this purpose. Current biological dosimetry concepts suggest that there does not appear to be any bio-indicator that could reliably measure the very low doses that are routinely measured by the physical devices presently in use. Nonetheless, bio-indicators may be useful in providing valuable supplementary information in cases of unusual radiation exposures, such as when the estimated body doses are doubtful because of lack of proper physical measurements, or in cases where available results need to be confirmed for medical treatment plannings. This report evaluates the present state of biological dosimetry and, in particular, assesses the efficiency and limits of individual indicators. This has led to the recommendation of a few promising research areas that may result in the development of appropriate biological dosimeters for operational and emergency needs at Chalk River

  1. Research toward the development of a biologically based dose response assessment for inorganic arsenic carcinogenicity: A progress report

    International Nuclear Information System (INIS)

    Clewell, Harvey J.; Thomas, Russell S.; Gentry, P. Robinan; Crump, Kenny S.; Kenyon, Elaina M.; El-Masri, Hisham A.; Yager, Janice W.

    2007-01-01

    Cancer risk assessments for inorganic arsenic have been based on human epidemiological data, assuming a linear dose response below the range of observation of tumors. Part of the reason for the continued use of the linear approach in arsenic risk assessments is the lack of an adequate biologically based dose response (BBDR) model that could provide a quantitative basis for an alternative nonlinear approach. This paper describes elements of an ongoing collaborative research effort between the CIIT Centers for Health Research, the U.S. Environmental Protection Agency, ENVIRON International, and EPRI to develop BBDR modeling approaches that could be used to inform a nonlinear cancer dose response assessment for inorganic arsenic. These efforts are focused on: (1) the refinement of physiologically based pharmacokinetic (PBPK) models of the kinetics of inorganic arsenic and its metabolites in the mouse and human; (2) the investigation of mathematical solutions for multi-stage cancer models involving multiple pathways of cell transformation; (3) the review and evaluation of the literature on the dose response for the genomic effects of arsenic; and (4) the collection of data on the dose response for genomic changes in the urinary bladder (a human target tissue for arsenic carcinogenesis) associated with in vivo drinking water exposures in the mouse as well as in vitro exposures of both mouse and human cells. An approach is proposed for conducting a biologically based margin of exposure risk assessment for inorganic arsenic using the in vitro dose response for the expression of genes associated with the obligatory precursor events for arsenic tumorigenesis

  2. Interactive Rapid Dose Assessment Model (IRDAM): reactor-accident assessment methods. Vol.2

    International Nuclear Information System (INIS)

    Poeton, R.W.; Moeller, M.P.; Laughlin, G.J.; Desrosiers, A.E.

    1983-05-01

    As part of the continuing emphasis on emergency preparedness, the US Nuclear Regulatory Commission (NRC) sponsored the development of a rapid dose assessment system by Pacific Northwest Laboratory (PNL). This system, the Interactive Rapid Dose Assessment Model (IRDAM) is a micro-computer based program for rapidly assessing the radiological impact of accidents at nuclear power plants. This document describes the technical bases for IRDAM including methods, models and assumptions used in calculations. IRDAM calculates whole body (5-cm depth) and infant thyroid doses at six fixed downwind distances between 500 and 20,000 meters. Radionuclides considered primarily consist of noble gases and radioiodines. In order to provide a rapid assessment capability consistent with the capacity of the Osborne-1 computer, certain simplifying approximations and assumptions are made. These are described, along with default values (assumptions used in the absence of specific input) in the text of this document. Two companion volumes to this one provide additional information on IRDAM. The user's Guide (NUREG/CR-3012, Volume 1) describes the setup and operation of equipment necessary to run IRDAM. Scenarios for Comparing Dose Assessment Models (NUREG/CR-3012, Volume 3) provides the results of calculations made by IRDAM and other models for specific accident scenarios

  3. Study, assessment of radioactive dose on China's population

    Energy Technology Data Exchange (ETDEWEB)

    Ziqiang, P.

    1984-05-10

    The national population dose is defined as the radioactive dose from both natural and artificial sources which is received by the entire Chinese population. The necessity and prospects for developing ways to assess China's national population dose and some noteworthy problems in this area are described.

  4. Real time source term and dose assessment

    International Nuclear Information System (INIS)

    Breznik, B.; Kovac, A.; Mlakar, P.

    2001-01-01

    The Dose Projection Programme is a tool for decision making in case of nuclear emergency. The essential input data for quick emergency evaluation in the case of hypothetical pressurised water reactor accident are following: source term, core damage assessment, fission product radioactivity, release source term and critical exposure pathways for an early phase of the release. A reduced number of radio-nuclides and simplified calculations can be used in dose calculation algorithm. Simple expert system personal computer programme has been developed for the Krsko Nuclear Power Plant for dose projection within the radius of few kilometers from the pressurised water reactor in early phase of an accident. The input data are instantaneous data of core activity, core damage indicators, release fractions, reduction factor of the release pathways, spray operation, release timing, and dispersion coefficient. Main dose projection steps are: accurate in-core radioactivity determination using reactor power input; core damage and in-containment source term assessment based on quick indications of instrumentation or on activity analysis data; user defines release pathway for typical PWR accident scenarius; dose calculation is performed only for exposure pathway critical for decision about evacuation or sheltering in early phase of an accident.(author)

  5. TSD-DOSE: A radiological dose assessment model for treatment, storage, and disposal facilities

    International Nuclear Information System (INIS)

    Pfingston, M.; Arnish, J.; LePoire, D.; Chen, S.-Y.

    1998-01-01

    Past practices at US Department of Energy (DOE) field facilities resulted in the presence of trace amounts of radioactive materials in some hazardous chemical wastes shipped from these facilities. In May 1991, the DOE Office of Waste Operations issued a nationwide moratorium on shipping all hazardous waste until procedures could be established to ensure that only nonradioactive hazardous waste would be shipped from DOE facilities to commercial treatment, storage, and disposal (TSD) facilities. To aid in assessing the potential impacts of shipments of mixed radioactive and chemically hazardous wastes, a radiological assessment computer model (or code) was developed on the basis of detailed assessments of potential radiological exposures and doses for eight commercial hazardous waste TSD facilities. The model, called TSD-DOSE, is designed to incorporate waste-specific and site-specific data to estimate potential radiological doses to on-site workers and the off-site public from waste-handling operations at a TSD facility. The code is intended to provide both DOE and commercial TSD facilities with a rapid and cost-effective method for assessing potential human radiation exposures from the processing of chemical wastes contaminated with trace amounts of radionuclides

  6. Development of computational pregnant female and fetus models and assessment of radiation dose from positron-emitting tracers

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Tianwu [Geneva University Hospital, Division of Nuclear Medicine and Molecular Imaging, Geneva (Switzerland); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine and Molecular Imaging, Geneva (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland); University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University of Southern Denmark, Department of Nuclear Medicine, Odense (Denmark)

    2016-12-15

    Molecular imaging using PET and hybrid (PET/CT and PET/MR) modalities nowadays plays a pivotal role in the clinical setting for diagnosis and staging, treatment response monitoring, and radiation therapy treatment planning of a wide range of oncologic malignancies. The developing embryo/fetus presents a high sensitivity to ionizing radiation. Therefore, estimation of the radiation dose delivered to the embryo/fetus and pregnant patients from PET examinations to assess potential radiation risks is highly praised. We constructed eight embryo/fetus models at various gestation periods with 25 identified tissues according to reference data recommended by the ICRP publication 89 representing the anatomy of the developing embryo/fetus. The developed embryo/fetus models were integrated into realistic anthropomorphic computational phantoms of the pregnant female and used for estimating, using Monte Carlo calculations, S-values of common positron-emitting radionuclides, organ absorbed dose, and effective dose of a number of positron-emitting labeled radiotracers. The absorbed dose is nonuniformly distributed in the fetus. The absorbed dose of the kidney and liver of the 8-week-old fetus are about 47.45 % and 44.76 % higher than the average absorbed dose of the fetal total body for all investigated radiotracers. For {sup 18}F-FDG, the fetal effective doses are 2.90E-02, 3.09E-02, 1.79E-02, 1.59E-02, 1.47E-02, 1.40E-02, 1.37E-02, and 1.27E-02 mSv/MBq at the 8th, 10th, 15th, 20th, 25th, 30th, 35th, and 38th weeks of gestation, respectively. The developed pregnant female/fetus models matching the ICRP reference data can be exploited by dedicated software packages for internal and external dose calculations. The generated S-values will be useful to produce new standardized dose estimates to pregnant patients and embryo/fetus from a variety of positron-emitting labeled radiotracers. (orig.)

  7. Development of a dose assessment computer code for the NPP severe accident at intermediate level - Korean case

    International Nuclear Information System (INIS)

    Cheong, J.H.; Lee, K.J.; Cho, H.Y.; Lim, J.H.

    1993-01-01

    A real-time dose assessment computer code named RADCON (RADiological CONsequence analysis) has been developed. An approximation method describing the distribution of radionuclides in a puff was proposed and implemented in the code. This method is expected to reduce the time required to calculate the cloud shine (external dose from radioactive plumes). RADCON can simulate an NPP emergency situation by considering complex topography and continuous washout phenomena and provide a function of effective emergency planning. To verify the code results, RADCON has been compared with RASCAL, which was developed for the U.S. NRC by ORNL, for eight hypothetical accident scenarios. Sensitivity analysis was also performed for the important input parameters. (2 tabs., 3 figs.)

  8. Real-time assessment of exposure dose to workers in radiological environments during decommissioning of nuclear facilities

    International Nuclear Information System (INIS)

    Jeong, KwanSeong; Choi, ByungSeon; Moon, JeiKwon; Hyun, Dongjun; Lee, Jonghwan; Kim, IkJune; Kim, GeunHo; Seo, JaeSeok; Jeong, SeongYoung; Lee, JungJun; Song, HaeSang; Lee, SangWha; Son, BongKi

    2014-01-01

    Highlights: • The method of exposure dose assessment to workers during decommissioning of nuclear facilities. • The environments of simulation were designed under a virtual reality. • To assess exposure dose to workers, human model was developed within a virtual reality. - Abstract: This objective of this paper is to develop a method to simulate and assess the exposure dose to workers during decommissioning of nuclear facilities. To simulate several scenarios, decommissioning environments were designed using virtual reality. To assess exposure dose to workers, a human model was also developed using virtual reality. The exposure dose was measured and assessed under the principle of ALARA in accordance with radiological environmental change. This method will make it possible to plan for the exposure dose to workers during decommissioning of nuclear facilities

  9. Occupational dose assessment in interventional cardiology in Serbia

    International Nuclear Information System (INIS)

    Kaljevic, J.; Ciraj-Bjelac, O.; Stankovic, J.; Arandjic, D.; Bozovic, P.; Antic, V.

    2016-01-01

    The objective of this work is to assess the occupational dose in interventional cardiology in a large hospital in Belgrade, Serbia. A double-dosimetry method was applied for the estimation of whole-body dose, using thermoluminescent dosemeters, calibrated in terms of the personal dose equivalent H p (10). Besides the double-dosimetry method, eye dose was also estimated by means of measuring ambient dose equivalent, H*(10), and doses per procedure were reported. Doses were assessed for 13 physicians, 6 nurses and 10 radiographers, for 2 consequent years. The maximum annual effective dose assessed was 4.3, 2.1 and 1.3 mSv for physicians, nurses and radiographers, respectively. The maximum doses recorded by the dosemeter worn at the collar level (over the apron) were 16.8, 11.9 and 4.5 mSv, respectively. This value was used for the eye lens dose assessment. Estimated doses are in accordance with or higher than annual dose limits for the occupational exposure. (authors)

  10. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer

    International Nuclear Information System (INIS)

    Oliveira, Jetro Pereira de; Batista, Delano Valdivino Santos; Bardella, Lucia Helena; Carvalho, Arnaldo Rangel

    2009-01-01

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  11. Combination TLD/TED dose assessment

    International Nuclear Information System (INIS)

    Parkhurst, M.A.

    1992-11-01

    During the early 1980s, an appraisal of dosimetry programs at US Department of Energy (DOE) facilities identified a significant weakness in dose assessment in fast neutron environments. Basing neutron dose equivalent on thermoluminescence dosimeters (TLDS) was not entirely satisfactory for environments that had not been well characterized. In most operational situations, the dosimeters overrespond to neutrons, and this overresponse could be further exaggerated with changes in the neutron quality factor (Q). Because TLDs are energy dependent with an excellent response to thermal and low-energy neutrons but a weak response to fast neutrons, calibrating the dosimetry system to account for mixed and moderated neutron energy fields is a difficult and seldom satisfactory exercise. To increase the detection of fast neutrons and help improve the accuracy of dose equivalent determinations, a combination dosimeter was developed using TLDs to detect thermal and low-energy neutrons and a track-etch detector (TED) to detect fast neutrons. By combining the albedo energy response function of the TLDs with the track detector elements, the dosimeter can nearly match the fluence-to-dose equivalent conversion curve. The polymer CR-39 has neutron detection characteristics superior to other materials tested. The CR-39 track detector is beta and gamma insensitive and does not require backscatter (albedo) from the body to detect the exposure. As part of DOE's Personnel Neutron and Upgrade Program, we have been developing a R-39 track detector over the past decade to address detection and measurement of fast neutrons. Using CR-39 TEDs in combination with TLDs will now allow us to detect the wide spectrum of occupational neutron energies and assign dose equivalents much more confidently

  12. Epidemiological methods for assessing dose-response and dose-effect relationships

    DEFF Research Database (Denmark)

    Kjellström, Tord; Grandjean, Philippe

    2007-01-01

    Selected Molecular Mechanisms of Metal Toxicity and Carcinogenicity General Considerations of Dose-Effect and Dose-Response Relationships Interactions in Metal Toxicology Epidemiological Methods for Assessing Dose-Response and Dose-Effect Relationships Essential Metals: Assessing Risks from Deficiency......Description Handbook of the Toxicology of Metals is the standard reference work for physicians, toxicologists and engineers in the field of environmental and occupational health. This new edition is a comprehensive review of the effects on biological systems from metallic elements...... access to a broad range of basic toxicological data and also gives a general introduction to the toxicology of metallic compounds. Audience Toxicologists, physicians, and engineers in the fields of environmental and occupational health as well as libraries in these disciplines. Will also be a useful...

  13. TSD-DOSE : a radiological dose assessment model for treatment, storage, and disposal facilities

    International Nuclear Information System (INIS)

    Pfingston, M.

    1998-01-01

    In May 1991, the U.S. Department of Energy (DOE), Office of Waste Operations, issued a nationwide moratorium on shipping slightly radioactive mixed waste from DOE facilities to commercial treatment, storage, and disposal (TSD) facilities. Studies were subsequently conducted to evaluate the radiological impacts associated with DOE's prior shipments through DOE's authorized release process under DOE Order 5400.5. To support this endeavor, a radiological assessment computer code--TSD-DOSE (Version 1.1)--was developed and issued by DOE in 1997. The code was developed on the basis of detailed radiological assessments performed for eight commercial hazardous waste TSD facilities. It was designed to utilize waste-specific and site-specific data to estimate potential radiological doses to on-site workers and the off-site public from waste handling operations at a TSD facility. The code has since been released for use by DOE field offices and was recently used by DOE to evaluate the release of septic waste containing residual radioactive material to a TSD facility licensed under the Resource Conservation and Recovery Act. Revisions to the code were initiated in 1997 to incorporate comments received from users and to increase TSD-DOSE's capability, accuracy, and flexibility. These updates included incorporation of the method used to estimate external radiation doses from DOE's RESRAD model and expansion of the source term to include 85 radionuclides. In addition, a detailed verification and benchmarking analysis was performed

  14. Assessment of internal doses

    CERN Document Server

    Rahola, T; Falk, R; Isaksson, M; Skuterud, L

    2002-01-01

    There is a definite need for training in dose calculation. Our first course was successful and was followed by a second, both courses were fully booked. An example of new tools for software products for bioassay analysis and internal dose assessment is the Integrated Modules for Bioassay Analysis (IMBA) were demonstrated at the second course. This suite of quality assured code modules have been adopted in the UK as the standard for regulatory assessment purposes. The intercomparison measurements are an important part of the Quality Assurance work. In what is known as the sup O utside workers ' directive it is stated that the internal dose measurements shall be included in the European Unions supervision system for radiation protection. The emergency preparedness regarding internal contamination was much improved by the training with and calibration of handheld instruments from participants' laboratories. More improvement will be gained with the handbook giving practical instructions on what to do in case of e...

  15. Radiological assessment. A textbook on environmental dose analysis

    Energy Technology Data Exchange (ETDEWEB)

    Till, J.E.; Meyer, H.R. (eds.)

    1983-09-01

    Radiological assessment is the quantitative process of estimating the consequences to humans resulting from the release of radionuclides to the biosphere. It is a multidisciplinary subject requiring the expertise of a number of individuals in order to predict source terms, describe environmental transport, calculate internal and external dose, and extrapolate dose to health effects. Up to this time there has been available no comprehensive book describing, on a uniform and comprehensive level, the techniques and models used in radiological assessment. Radiological Assessment is based on material presented at the 1980 Health Physics Society Summer School held in Seattle, Washington. The material has been expanded and edited to make it comprehensive in scope and useful as a text. Topics covered include (1) source terms for nuclear facilities and Medical and Industrial sites; (2) transport of radionuclides in the atmosphere; (3) transport of radionuclides in surface waters; (4) transport of radionuclides in groundwater; (5) terrestrial and aquatic food chain pathways; (6) reference man; a system for internal dose calculations; (7) internal dosimetry; (8) external dosimetry; (9) models for special-case radionuclides; (10) calculation of health effects in irradiated populations; (11) evaluation of uncertainties in environmental radiological assessment models; (12) regulatory standards for environmental releases of radionuclides; (13) development of computer codes for radiological assessment; and (14) assessment of accidental releases of radionuclides.

  16. Radiological assessment. A textbook on environmental dose analysis

    International Nuclear Information System (INIS)

    Till, J.E.; Meyer, H.R.

    1983-09-01

    Radiological assessment is the quantitative process of estimating the consequences to humans resulting from the release of radionuclides to the biosphere. It is a multidisciplinary subject requiring the expertise of a number of individuals in order to predict source terms, describe environmental transport, calculate internal and external dose, and extrapolate dose to health effects. Up to this time there has been available no comprehensive book describing, on a uniform and comprehensive level, the techniques and models used in radiological assessment. Radiological Assessment is based on material presented at the 1980 Health Physics Society Summer School held in Seattle, Washington. The material has been expanded and edited to make it comprehensive in scope and useful as a text. Topics covered include (1) source terms for nuclear facilities and Medical and Industrial sites; (2) transport of radionuclides in the atmosphere; (3) transport of radionuclides in surface waters; (4) transport of radionuclides in groundwater; (5) terrestrial and aquatic food chain pathways; (6) reference man; a system for internal dose calculations; (7) internal dosimetry; (8) external dosimetry; (9) models for special-case radionuclides; (10) calculation of health effects in irradiated populations; (11) evaluation of uncertainties in environmental radiological assessment models; (12) regulatory standards for environmental releases of radionuclides; (13) development of computer codes for radiological assessment; and (14) assessment of accidental releases of radionuclides

  17. An updated dose assessment for Rongelap Island

    Energy Technology Data Exchange (ETDEWEB)

    Robison, W.L.; Conrado, C.L.; Bogen, K.T.

    1994-07-01

    We have updated the radiological dose assessment for Rongelap Island at Rongelap Atoll using data generated from field trips to the atoll during 1986 through 1993. The data base used for this dose assessment is ten fold greater than that available for the 1982 assessment. Details of each data base are presented along with details about the methods used to calculate the dose from each exposure pathway. The doses are calculated for a resettlement date of January 1, 1995. The maximum annual effective dose is 0.26 mSv y{sup {minus}1} (26 mrem y{sup {minus}1}). The estimated 30-, 50-, and 70-y integral effective doses are 0.0059 Sv (0.59 rem), 0.0082 Sv (0.82 rem), and 0.0097 Sv (0.97 rem), respectively. More than 95% of these estimated doses are due to 137-Cesium ({sup 137}Cs). About 1.5% of the estimated dose is contributed by 90-Strontium ({sup 90}Sr), and about the same amount each by 239+240-Plutonium ({sup 239+240}PU), and 241-Americium ({sup 241}Am).

  18. Developing a flexible and verifiable integrated dose assessment capability

    International Nuclear Information System (INIS)

    Parzyck, D.C.; Rhea, T.A.; Copenhaver, E.D.; Bogard, J.S.

    1987-01-01

    A flexible yet verifiable system of computing and recording personnel doses is needed. Recent directions in statutes establish the trend of combining internal and external doses. We are developing a Health Physics Information Management System (HPIMS) that will centralize dosimetry calculations and data storage; integrate health physics records with other health-related disciplines, such as industrial hygiene, medicine, and safety; provide a more auditable system with published algorithms and clearly defined flowcharts of system operation; readily facilitate future changes dictated by new regulations, new dosimetric models, and new systems of units; and address ad-hoc inquiries regarding worker/workplace interactions, including potential synergisms with non-radiation exposures. The system is modular and provides a high degree of isolation from low-level detail, allowing flexibility for changes without adversely affecting other parts of the system. 10 refs., 3 figs

  19. A real-time internal dose assessment exercise

    International Nuclear Information System (INIS)

    Bingham, D.; Bull, R. K.

    2013-01-01

    A real-time internal dose assessment exercise has been conducted in which participants were required to make decisions about sampling requirements, seek relevant information about the 'incident' and make various interim dose assessments. At the end of the exercise, each participant was requested to make a formal assessment, providing statements of the methods, models and assumptions used in that assessment. In this paper we describe how the hypothetical assessment case was set up and the exercise was conducted, the responses of the participants and the assessments of dose that they made. Finally we discuss the lessons learnt from the exercise and suggest how the exercise may be adapted to a wider range of participants. (authors)

  20. TU-H-CAMPUS-JeP3-02: Automated Dose Accumulation and Dose Accuracy Assessment for Online Or Offline Adaptive Replanning

    International Nuclear Information System (INIS)

    Chen, G; Ahunbay, E; Li, X

    2016-01-01

    Purpose: With introduction of high-quality treatment imaging during radiation therapy (RT) delivery, e.g., MR-Linac, adaptive replanning of either online or offline becomes appealing. Dose accumulation of delivered fractions, a prerequisite for the adaptive replanning, can be cumbersome and inaccurate. The purpose of this work is to develop an automated process to accumulate daily doses and to assess the dose accumulation accuracy voxel-by-voxel for adaptive replanning. Methods: The process includes the following main steps: 1) reconstructing daily dose for each delivered fraction with a treatment planning system (Monaco, Elekta) based on the daily images using machine delivery log file and considering patient repositioning if applicable, 2) overlaying the daily dose to the planning image based on deformable image registering (DIR) (ADMIRE, Elekta), 3) assessing voxel dose deformation accuracy based on deformation field using predetermined criteria, and 4) outputting accumulated dose and dose-accuracy volume histograms and parameters. Daily CTs acquired using a CT-on-rails during routine CT-guided RT for sample patients with head and neck and prostate cancers were used to test the process. Results: Daily and accumulated doses (dose-volume histograms, etc) along with their accuracies (dose-accuracy volume histogram) can be robustly generated using the proposed process. The test data for a head and neck cancer case shows that the gross tumor volume decreased by 20% towards the end of treatment course, and the parotid gland mean dose increased by 10%. Such information would trigger adaptive replanning for the subsequent fractions. The voxel-based accuracy in the accumulated dose showed that errors in accumulated dose near rigid structures were small. Conclusion: A procedure as well as necessary tools to automatically accumulate daily dose and assess dose accumulation accuracy is developed and is useful for adaptive replanning. Partially supported by Elekta, Inc.

  1. Integrated numerical platforms for environmental dose assessments of large tritium inventory facilities

    International Nuclear Information System (INIS)

    Castro, P.; Ardao, J.; Velarde, M.; Sedano, L.; Xiberta, J.

    2013-01-01

    Related with a prospected new scenario of large inventory tritium facilities [KATRIN at TLK, CANDUs, ITER, EAST, other coming] the prescribed dosimetric limits by ICRP-60 for tritium committed-doses are under discussion requiring, in parallel, to surmount the highly conservative assessments by increasing the refinement of dosimetric-assessments in many aspects. Precise Lagrangian-computations of dosimetric cloud-evolution after standardized (normal/incidental/SBO) tritium cloud emissions are today numerically open to the perfect match of real-time meteorological-data, and patterns data at diverse scales for prompt/early and chronic tritium dose assessments. The trends towards integrated-numerical-platforms for environmental-dose assessments of large tritium inventory facilities under development.

  2. Characteristics of environmental gamma-rays and dose assessment

    International Nuclear Information System (INIS)

    Saito, Kimiaki; Moriuchi, Shigeru

    1986-01-01

    Environmental radioactivity has attracted much attention in terms of exposure to the population, although its exposure doses are minimal. This paper presents problems encountered in the assessment of exposure doses using model and monitoring systems, focusing on the characteristics, such as energy distribution, direction distribution, and site, of environmental gamma-rays. The assessment of outdoor and indoor exposure doses of natural gamma-rays is discussed in relation to the shielding effect of the human body. In the assessment of artificial gamma-rays, calculation of exposure doses using build-up factor, the shielding effect of the human body, and energy dependency of the measuring instrument are covered. A continuing elucidation about uncertainties in dose assessment is emphasized. (Namekawa, K.)

  3. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    International Nuclear Information System (INIS)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan

    2012-01-01

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED adj ). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED adj between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED adj that differed by up to 44% from effective dose estimates that were not

  4. The embryogenesis of dose assessment at Hanford

    International Nuclear Information System (INIS)

    Foster, R.F.

    1990-01-01

    Several significant events occurred between 1955 and 1960 that resulted in major changes in environmental monitoring at Hanford and in the initiation of comprehensive dose assessments. These included: (1) specification of dose limits for nonoccupational exposure (including internal emitters); (2) a national and international awakening to the need for managing the disposal of radioactive wastes; (3) identification of the most important radionuclides and their sources of exposure; (4) data that quantified the transfer coefficients of nuclides along environmental pathways; and (5) development of greatly improved radiation detection instrumentation. In response to a growing need, the Hanford Laboratories formed the Environmental Studies and Evaluation component. This group revamped the monitoring and sampling programs so that analytical results contributed directly to dose estimation. Special studies were conducted to ascertain local dietary and recreational habits that affected dose calculations and to calibrate the models. These studies involved extensive contact with the public and governmental agencies, which elicited a positive reaction

  5. A user friendly database for use in ALARA job dose assessment

    Energy Technology Data Exchange (ETDEWEB)

    Zodiates, A.M.; Willcock, A. [Cheshire, England (United Kingdom)

    1995-03-01

    The pressurized water reactor (PWR) design chosen for adoption by Nuclear Electric plc was based on the Westinghouse Standard Nuclear Unit Power Plant (SNUPPS). This design was developed to meet the United Kingdom requirements and these improvements are embodied in the Sizewell B plant which will start commercial operation in 1994. A user-friendly database was developed to assist the station in the dose and ALARP assessments of the work expected to be carried out during station operation and outage. The database stores the information in an easily accessible form and enables updating, editing, retrieval, and searches of the information. The database contains job-related information such as job locations, number of workers required, job times, and the expected plant doserates. It also contains the means to flag job requirements such as requirements for temporary shielding, flushing, scaffolding, etc. Typical uses of the database are envisaged to be in the prediction of occupational doses, the identification of high collective and individual dose jobs, use in ALARP assessments, setting of dose targets, monitoring of dose control performance, and others.

  6. Development of the voxel computational phantoms of pediatric patients and their application to organ dose assessment

    Science.gov (United States)

    Lee, Choonik

    A series of realistic voxel computational phantoms of pediatric patients were developed and then used for the radiation risk assessment for various exposure scenarios. The high-resolution computed tomographic images of live patients were utilized for the development of the five voxel phantoms of pediatric patients, 9-month male, 4-year female, 8-year female, 11-year male, and 14-year male. The phantoms were first developed as head and torso phantoms and then extended into whole body phantoms by utilizing computed tomographic images of a healthy adult volunteer. The whole body phantom series was modified to have the same anthropometrics with the most recent reference data reported by the international commission on radiological protection. The phantoms, named as the University of Florida series B, are the first complete set of the pediatric voxel phantoms having reference organ masses and total heights. As part of the dosimetry study, the investigation on skeletal tissue dosimetry methods was performed for better understanding of the radiation dose to the active bone marrow and bone endosteum. All of the currently available methodologies were inter-compared and benchmarked with the paired-image radiation transport model. The dosimetric characteristics of the phantoms were investigated by using Monte Carlo simulation of the broad parallel beams of external phantom in anterior-posterior, posterior-anterior, left lateral, right lateral, rotational, and isotropic angles. Organ dose conversion coefficients were calculated for extensive photon energies and compared with the conventional stylized pediatric phantoms of Oak Ridge National Laboratory. The multi-slice helical computed tomography exams were simulated using Monte Carlo simulation code for various exams protocols, head, chest, abdomen, pelvis, and chest-abdomen-pelvis studies. Results have found realistic estimates of the effective doses for frequently used protocols in pediatric radiology. The results were very

  7. Nonparametric estimation of benchmark doses in environmental risk assessment

    Science.gov (United States)

    Piegorsch, Walter W.; Xiong, Hui; Bhattacharya, Rabi N.; Lin, Lizhen

    2013-01-01

    Summary An important statistical objective in environmental risk analysis is estimation of minimum exposure levels, called benchmark doses (BMDs), that induce a pre-specified benchmark response in a dose-response experiment. In such settings, representations of the risk are traditionally based on a parametric dose-response model. It is a well-known concern, however, that if the chosen parametric form is misspecified, inaccurate and possibly unsafe low-dose inferences can result. We apply a nonparametric approach for calculating benchmark doses, based on an isotonic regression method for dose-response estimation with quantal-response data (Bhattacharya and Kong, 2007). We determine the large-sample properties of the estimator, develop bootstrap-based confidence limits on the BMDs, and explore the confidence limits’ small-sample properties via a short simulation study. An example from cancer risk assessment illustrates the calculations. PMID:23914133

  8. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    Energy Technology Data Exchange (ETDEWEB)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan [Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States) and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Department of Physics, Duke University, Durham, North Carolina 27710 (United States); and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States)

    2012-11-15

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose

  9. An Internal Dose Assessment Associated with Personal Food Intake

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joeun; Jae, Moosung [Hanyang University, Seoul (Korea, Republic of); Hwang, Wontae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    ICRP (International Commission on Radiological Protection), Therefore, had recommended the concept of 'Critical Group'. Recently the ICRP has recommended the use of 'Representative Person' on the new basic recommendation 103. On the other hand the U.S. NRC (Nuclear Regulatory Commission) has adopted more conservative concept, 'Maximum Exposed Individuals (MEI)' of critical Group. The dose assessment in Korea is based on MEI. Although dose assessment based on MEI is easy to receive the permission of the regulatory authority, it is not efficient. Meanwhile, the internal dose by food consumption takes an important part. Therefore, in this study, the internal dose assessment was performed in accordance with ICRP's new recommendations. The internal dose assessment was performed in accordance with ICRP's new recommendations. It showed 13.2% decreased of the annual internal dose due to gaseous effluents by replacing MEI to the concept of representative person. Also, this calculation based on new ICRP's recommendation has to be extended to all areas of individual dose assessment. Then, more accurate and efficient values might be obtained for dose assessment.

  10. Dose-stress synergism in cancer risk assessment

    International Nuclear Information System (INIS)

    Pop-Jordanova, N.; Pop-Jordanov, J.

    2001-01-01

    Our hypothesis is that the relatively low risk of cancer or leukaemia from depleted uranium, as predicted by the World Health Organization and the International Atomic Energy Agency, is a result of neglecting the synergism between physico-chemical agents and psychological stress agents (here shortly denoted as dose-stress synergism). We use the modified risk assessment model that comprises a psycho-somatic extension, originally developed by us for assessing the risks of energy sources. Our preliminary meta-analysis of animal and human studies on cancers confirmed the existence of stress effects, including the amplifying synergism. Consequently, the psychological stress can increase the probability of even small toxic chemical or ionizing radiation exposure to produce malignancy. Such dose-stress synergism might influence the health risks among military personnel and the residents in the highly stressful environment in the Balkans. Further investigation is needed to estimate the order of magnitude of these combined effects in particular circumstances. (Original)

  11. A radiological dose assessment for the Port Hope conversion facility

    International Nuclear Information System (INIS)

    Garisto, N.C.; Cooper, F.; Janes, A.; Stager, R.; Peters, R.

    2011-01-01

    The Port Hope Conversion Facility (PHCF) receives uranium trioxide for conversion to uranium hexafluoride (UF 6 ) or uranium dioxide (UO 2 ). The PHCF Site has a long history of industrial use. A Radiological Dose Assessment was undertaken as part of a Site Wide Risk Assessment. This assessment took into account all possible human receptors, both workers and members of the public. This paper focuses on a radiological assessment of dose to members of the public. The doses to members of the public from terrestrial pathways were added to the doses from aquatic pathways to obtain overall dose to receptors. The benchmark used in the assessment is 1 mSv/y. The estimated doses related to PHCF operations are much lower than the dose limit. (author)

  12. Dose assessment for Greifswald and Cadarache

    International Nuclear Information System (INIS)

    Raskob, W.

    1996-07-01

    Probabilistic dose assessments for accidental atmospheric releases of tritium and activation products as well as releases under normal operation conditions were performed for the sites of Greifswald, Germany, and Cadarache, France. Additionally, aquatic releases were considered for both sites. No country specific rules were applied and the input parameters were adapted as far as possible to those used within former ITER studies to have a better comparison to site independent dose assessments performed in the frame of ITER. The main goal was to complete the generic data base with site specific values. The agreement between the results from the ITER study on atmospheric releases and the two sites are rather good for tritium, whereas the ITER reference dose values for the activation product releases are often lower, than the maximum doses for Greifswald and Cadarache. However, the percentile values fit better to the deterministic approach of ITER. Within all scenarios, the consequences of aquatic releases are in nearly all cases smaller than those from comparable releases to the atmosphere (HTO and steel). This rule is only broken once in case of accidental releases of activated steel from Cadarache. However, the uncertainties associated with the aquatic assessments are rather high and a better data base is needed to obtain more realistic and thus more reliable dose values. (orig.) [de

  13. ARAC: a computer-based emergency dose-assessment service

    International Nuclear Information System (INIS)

    Sullivan, T.J.

    1990-01-01

    Over the past 15 years, the Lawrence Livermore National Laboratory's Atmospheric Release Advisory Capability (ARAC) has developed and evolved a computer-based, real-time, radiological-dose-assessment service for the United States Departments of Energy and Defense. This service is built on the integrated components of real-time computer-acquired meteorological data, extensive computer databases, numerical atmospheric-dispersion models, graphical displays, and operational-assessment-staff expertise. The focus of ARAC is the off-site problem where regional meteorology and topography are dominant influences on transport and dispersion. Through application to numerous radiological accidents/releases on scales from small accidental ventings to the Chernobyl reactor disaster, ARAC has developed methods to provide emergency dose assessments from the local to the hemispheric scale. As the power of computers has evolved inversely with respect to cost and size, ARAC has expanded its service and reduced the response time from hours to minutes for an accident within the United States. Concurrently the quality of the assessments has improved as more advanced models have been developed and incorporated into the ARAC system. Over the past six years, the number of directly connected facilities has increased from 6 to 73. All major U.S. Federal agencies now have access to ARAC via the Department of Energy. This assures a level of consistency as well as experience. ARAC maintains its real-time skills by participation in approximately 150 exercises per year; ARAC also continuously validates its modeling systems by application to all available tracer experiments and data sets

  14. Howard Hughes Medical Institute dose assessment survey

    International Nuclear Information System (INIS)

    O'Brien, S.L.; McDougall, M.M.; Barkley, W.E.

    1996-01-01

    Biomedical science researchers often express frustration that health physics practices vary widely between individual institutions. A survey examining both internal and external dose assessment practices was devised and mailed to fifty institutions supporting biomedical science research. The results indicate that health physics dose assessment practices and policies are highly variable. Factors which may contribute to the degree of variation are discussed. 2 tabs

  15. Non-monotonic dose-response relationships and endocrine disruptors: a qualitative method of assessment

    OpenAIRE

    Lagarde, Fabien; Beausoleil, Claire; Belcher, Scott M; Belzunces, Luc P; Emond, Claude; Guerbet, Michel; Rousselle, Christophe

    2015-01-01

    International audience; Experimental studies investigating the effects of endocrine disruptors frequently identify potential unconventional dose-response relationships called non-monotonic dose-response (NMDR) relationships. Standardized approaches for investigating NMDR relationships in a risk assessment context are missing. The aim of this work was to develop criteria for assessing the strength of NMDR relationships. A literature search was conducted to identify published studies that repor...

  16. Dose assessment in the Marshall Islands

    International Nuclear Information System (INIS)

    Robison, William L.

    1978-01-01

    Bikini Atoll and Enewetak Atoll in the Marshall Islands were the sites of major U.S. weapons testing from 1948 through 1958. Both the Bikini and Knewetak people have expressed a desire to return to their native Atolls. In 1968 clean-up and resettlement of Bikini was begun. In 1972-73 the initial survey of Enewetak Atoll was conducted and clean-up began in 1977. Surveys have been conducted at both Atolls to establish the concentrations of radionuclides in the biota and to determine the external exposure rates. Subsequent to the surveys dose assessments have been made to determine the potential dose to returning (100) populations at both Atolls. This talk will include discussions of the relative importance of the critical exposure pathways (i.e., external exposure, inhalation, marine, terrestrial and drinking water), the predominant radionuclides contributing to the predicted doses for each pathway, the doses predicted for alternate living patterns, comparison to Federal Guidelines, the comparison between Atolls, some of the social problems created by adherence to Federal Guidelines and the follow-up research identified and initiated to help refine the dose assessments and better predict the long term use of the Atolls (86). (author)

  17. Dose assessment considering evolution of the biosphere

    International Nuclear Information System (INIS)

    Karlsson, Sara; Bergstroem, Ulla

    2002-01-01

    Swedish Nuclear Fuel and Waste Management AB (SKB) is presently updating the safety assessment for SFR (Final repository for radioactive operational waste) in Sweden. The bio-spheric part of the analysis is performed by Studsvik Eco and Safety AB. According to the regulations the safety of the repository has to be accounted for different possible courses of the development of the biosphere. A number of studies have been carried out during the past years to investigate and document the biosphere in the area surrounding the repository. Modelling of shore-level displacement by land uplift, coastal water exchange and sedimentation have provided data for prediction of the evolution of the area. The prediction is done without considering a future change in climatic conditions. The results from this study show that accumulation of radionuclides in sediments is an important process to simulate when performing dose assessments covering biosphere evolution. The dose calculated for the first years of the period with agricultural use of the contaminated sediments may be severely underestimated in a scenario with large accumulation in coastal and lake stages. (LN)

  18. Objective assessment of image quality and dose reduction in CT iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Vaishnav, J. Y., E-mail: jay.vaishnav@fda.hhs.gov; Jung, W. C. [Diagnostic X-Ray Systems Branch, Office of In Vitro Diagnostic Devices and Radiological Health, Center for Devices and Radiological Health, United States Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, Maryland 20993 (United States); Popescu, L. M.; Zeng, R.; Myers, K. J. [Division of Imaging and Applied Mathematics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, United States Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, Maryland 20993 (United States)

    2014-07-15

    Purpose: Iterative reconstruction (IR) algorithms have the potential to reduce radiation dose in CT diagnostic imaging. As these algorithms become available on the market, a standardizable method of quantifying the dose reduction that a particular IR method can achieve would be valuable. Such a method would assist manufacturers in making promotional claims about dose reduction, buyers in comparing different devices, physicists in independently validating the claims, and the United States Food and Drug Administration in regulating the labeling of CT devices. However, the nonlinear nature of commercially available IR algorithms poses challenges to objectively assessing image quality, a necessary step in establishing the amount of dose reduction that a given IR algorithm can achieve without compromising that image quality. This review paper seeks to consolidate information relevant to objectively assessing the quality of CT IR images, and thereby measuring the level of dose reduction that a given IR algorithm can achieve. Methods: The authors discuss task-based methods for assessing the quality of CT IR images and evaluating dose reduction. Results: The authors explain and review recent literature on signal detection and localization tasks in CT IR image quality assessment, the design of an appropriate phantom for these tasks, possible choices of observers (including human and model observers), and methods of evaluating observer performance. Conclusions: Standardizing the measurement of dose reduction is a problem of broad interest to the CT community and to public health. A necessary step in the process is the objective assessment of CT image quality, for which various task-based methods may be suitable. This paper attempts to consolidate recent literature that is relevant to the development and implementation of task-based methods for the assessment of CT IR image quality.

  19. Objective assessment of image quality and dose reduction in CT iterative reconstruction

    International Nuclear Information System (INIS)

    Vaishnav, J. Y.; Jung, W. C.; Popescu, L. M.; Zeng, R.; Myers, K. J.

    2014-01-01

    Purpose: Iterative reconstruction (IR) algorithms have the potential to reduce radiation dose in CT diagnostic imaging. As these algorithms become available on the market, a standardizable method of quantifying the dose reduction that a particular IR method can achieve would be valuable. Such a method would assist manufacturers in making promotional claims about dose reduction, buyers in comparing different devices, physicists in independently validating the claims, and the United States Food and Drug Administration in regulating the labeling of CT devices. However, the nonlinear nature of commercially available IR algorithms poses challenges to objectively assessing image quality, a necessary step in establishing the amount of dose reduction that a given IR algorithm can achieve without compromising that image quality. This review paper seeks to consolidate information relevant to objectively assessing the quality of CT IR images, and thereby measuring the level of dose reduction that a given IR algorithm can achieve. Methods: The authors discuss task-based methods for assessing the quality of CT IR images and evaluating dose reduction. Results: The authors explain and review recent literature on signal detection and localization tasks in CT IR image quality assessment, the design of an appropriate phantom for these tasks, possible choices of observers (including human and model observers), and methods of evaluating observer performance. Conclusions: Standardizing the measurement of dose reduction is a problem of broad interest to the CT community and to public health. A necessary step in the process is the objective assessment of CT image quality, for which various task-based methods may be suitable. This paper attempts to consolidate recent literature that is relevant to the development and implementation of task-based methods for the assessment of CT IR image quality

  20. Development of Internal Dose Assessment Program for Nuclear Power Plant Employees

    Energy Technology Data Exchange (ETDEWEB)

    Song, Myung Jae; Kang, Duck Won; Maeng, Sung Jun; Kim, Hee Geun; Son, Soon Whan; Lim, Young Kee; Son, Joong Kwon; Park, Keyoung Rock [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Jang, See Young; Ha, Jong Woo; Suh, Keyoung Won [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Oh, Oak Doo; Lee, Joong Woo; Yoon, Sung Sik [Yonsei University, Seoul (Korea, Republic of)

    1996-12-31

    Internal exposure monitoring based on new concept of radiation protection. Analysis and Performance test of the in vivo systems being operated in nuclear power plants in Korea. Design and fabrication of humanoid phantom for calibration of in vivo system. Development of internal dose evaluation code based on the ICRP 30 dosimetric model. (author). 44 refs., figs.

  1. WAZA-ARI. A dose assessment system for patients in CT scan

    International Nuclear Information System (INIS)

    Sato, Kaoru; Takahashi, Fumiaki; Endo, Akira; Ono, Koji; Ban, Nobuhiko; Hasegawa, Takayuki; Katsunuma, Yasushi; Yoshitake, Takayasu; Kai, Michiaki

    2015-01-01

    The Japan Atomic Energy Agency (JAEA) are now developing WAZA-ARI for improvement of management of exposure doses due to CT examination under the joint research with the Oita University of Nursing and Health Sciences. The trial version of WAZA-ARI has been released on 21 December 2012. In trial version, users can perform dose assessment by using organ dose database based on the average adult Japanese male (JM-103) and female (JF-103) voxel phantoms and a 4 years old female voxel phantom (UFF4). The homepage of WAZA-ARI has been accessed over 1000 times per month and 28421 times by the end of September 2014. We are developing WAZA-ARI version 2 as the extension version of dose calculation functions of WAZA-ARI. WAZA-ARI version 2 will be released by the end of March 2015. In WAZA-ARI version 2. Users can upload dose calculation results to WAZA-ARI version 2 server, and utilize improvement of the dose management of patients and the optimization of CT scan conditions. (author)

  2. Dose assessment for brachytherapy with Henschke applicator

    International Nuclear Information System (INIS)

    Yu, Pei-Chieh; Chao, Tsi-Chian; Tung, Chuan-Jong; Wu, Ching-Jung; Lee, Chung-Chi

    2011-01-01

    Dose perturbation caused by the Henschke applicator is a major concern for the brachytherapy planning system (BPS) in recent years. To investigate dose impact owing to neglect of the metal shielding effect, Monte Carlo (MC) simulation, BPS calculation, and film measurement have been performed for dose assessment in a water phantom. Additionally, a cylindrical air cavity representing the rectum was added into the MC simulation to study its effect on dose distribution. Monte Carlo N-Particle Transport Code (MCNP) was used in this study to simulate the dose distribution using a mesh tally. This Monte Carlo simulation has been validated using the TG-43 data in a previous report. For the measurement, the Henschke applicator was placed in a specially-designed phantom, and Gafchromic films were inserted in the center plane for 2D dose assessment. Isodose distributions with and without the Henschke applicator by the MC simulation show significant deviation from those by the BPS. For MC simulation, the isodose curves shrank more significantly when the metal applicator was applied. For the impact of the added air cavity, the results indicate that it is hard to distinguish between with and without the cavity. Thus, the rectum cavity has little impact on the dose distribution around the Henschke applicator.

  3. A Unified Probabilistic Framework for Dose-Response Assessment of Human Health Effects.

    Science.gov (United States)

    Chiu, Weihsueh A; Slob, Wout

    2015-12-01

    When chemical health hazards have been identified, probabilistic dose-response assessment ("hazard characterization") quantifies uncertainty and/or variability in toxicity as a function of human exposure. Existing probabilistic approaches differ for different types of endpoints or modes-of-action, lacking a unifying framework. We developed a unified framework for probabilistic dose-response assessment. We established a framework based on four principles: a) individual and population dose responses are distinct; b) dose-response relationships for all (including quantal) endpoints can be recast as relating to an underlying continuous measure of response at the individual level; c) for effects relevant to humans, "effect metrics" can be specified to define "toxicologically equivalent" sizes for this underlying individual response; and d) dose-response assessment requires making adjustments and accounting for uncertainty and variability. We then derived a step-by-step probabilistic approach for dose-response assessment of animal toxicology data similar to how nonprobabilistic reference doses are derived, illustrating the approach with example non-cancer and cancer datasets. Probabilistically derived exposure limits are based on estimating a "target human dose" (HDMI), which requires risk management-informed choices for the magnitude (M) of individual effect being protected against, the remaining incidence (I) of individuals with effects ≥ M in the population, and the percent confidence. In the example datasets, probabilistically derived 90% confidence intervals for HDMI values span a 40- to 60-fold range, where I = 1% of the population experiences ≥ M = 1%-10% effect sizes. Although some implementation challenges remain, this unified probabilistic framework can provide substantially more complete and transparent characterization of chemical hazards and support better-informed risk management decisions.

  4. REIDAC. A software package for retrospective dose assessment in internal contamination with radionuclides

    International Nuclear Information System (INIS)

    Kurihara, Osamu; Kanai, Katsuta; Takada, Chie; Takasaki, Koji; Ito, Kimio; Momose, Takumaro; Hato, Shinji; Ikeda, Hiroshi; Oeda, Mikihiro; Kurosawa, Naohiro; Fukutsu, Kumiko; Yamada, Yuji; Akashi, Makoto

    2007-01-01

    For cases of internal contamination with radionuclides, it is necessary to perform an internal dose assessment to facilitate radiation protection. For this purpose, the ICRP has supplied the dose coefficients and the retention and excretion rates for various radionuclides. However, these dosimetric quantities are calculated under typical conditions and are not necessarily detailed enough for dose assessment situations in which specific information on the incident or/and individual biokinetic characteristics could or should be taken into account retrospectively. This paper describes a newly developed PC-based software package called Retrospective Internal Dose Assessment Code (REIDAC) that meets the needs of retrospective dose assessment. REIDAC is made up of a series of calculation programs and a package of software. The former calculates the dosimetric quantities for any radionuclide being assessed and the latter provides a user with the graphical user interface (GUI) for executing the programs, editing parameter values and displaying results. The accuracy of REIDAC was verified by comparisons with dosimetric quantities given in the ICRP publications. This paper presents the basic structure of REIDAC and its calculation methods. Sensitivity analysis of the aerosol size for 239 Pu compounds and provisional calculations for wound contamination with 241 Am were performed as examples of the practical application of REIDAC. (author)

  5. Summary of the dose assessment tool for diagnostic X-ray CT, WAZA-ARIv2

    International Nuclear Information System (INIS)

    Koba, Yosuke

    2016-01-01

    WAZA-ARIv2 is the web-based open system for the dose assessment for diagnostic X-ray CT. Amid growing interest about the dose assessment for medical exposure, WAZA-ARIv2 is opened to the public from January 2015 and attracts rising attention. Using WAZA-ARIv2 system, users can calculate exposure dose to consider patient's age and body shape, and can register the calculation results on WAZA-ARIv2 server for checking as histogram statistics. This paper reviews the background of development of WAZA-ARI system, the comparison of characteristics between WAZA-ARIv2 and other tools, and the calculation method of organ dose in WAZA-ARIv2. (author)

  6. Computational assessment of effective dose and patient specific doses for kilovoltage stereotactic radiosurgery of wet age-related macular degeneration

    Science.gov (United States)

    Hanlon, Justin Mitchell

    Age-related macular degeneration (AMD) is a leading cause of vision loss and a major health problem for people over the age of 50 in industrialized nations. The current standard of care, ranibizumab, is used to help slow and in some cases stabilize the process of AMD, but requires frequent invasive injections into the eye. Interest continues for stereotactic radiosurgery (SRS), an option that provides a non-invasive treatment for the wet form of AMD, through the development of the IRay(TM) (Oraya Therapeutics, Inc., Newark, CA). The goal of this modality is to destroy choroidal neovascularization beneath the pigment epithelium via delivery of three 100 kVp photon beams entering through the sclera and overlapping on the macula delivering up to 24 Gy of therapeutic dose over a span of approximately 5 minutes. The divergent x-ray beams targeting the fovea are robotically positioned and the eye is gently immobilized by a suction-enabled contact lens. Device development requires assessment of patient effective dose, reference patient mean absorbed doses to radiosensitive tissues, and patient specific doses to the lens and optic nerve. A series of head phantoms, including both reference and patient specific, was derived from CT data and employed in conjunction with the MCNPX 2.5.0 radiation transport code to simulate treatment and evaluate absorbed doses to potential tissues-at-risk. The reference phantoms were used to evaluate effective dose and mean absorbed doses to several radiosensitive tissues. The optic nerve was modeled with changeable positions based on individual patient variability seen in a review of head CT scans gathered. Patient specific phantoms were used to determine the effect of varying anatomy and gaze. The results showed that absorbed doses to the non-targeted tissues were below the threshold levels for serious complications; specifically the development of radiogenic cataracts and radiation induced optic neuropathy (RON). The effective dose

  7. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Ra; Min, Byung Il; Park, Kihyun; Yang, Byung Mo; Suh, Kyung Suk [Nuclear Environmental Safety Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    The International Commission on Radiological Protection (ICRP) recommendations and the Federal Guidance Report (FGR) published by the U.S. Environmental Protection Agency (EPA) have been widely applied worldwide in the fields of radiation protection and dose assessment. The dose conversion coefficients of the ICRP and FGR are widely used for assessing exposure doses. However, before the coefficients are used, the user must thoroughly understand the derivation process of the coefficients to ensure that they are used appropriately in the evaluation. The ICRP provides recommendations to regulatory and advisory agencies, mainly in the form of guidance on the fundamental principles on which appropriate radiological protection can be based. The FGR provides federal and state agencies with technical information to assist their implementation of radiation protection programs for the U.S. population. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR is reviewed in this study. A thorough understanding of their background is essential for the proper use of dose conversion coefficients. The FGR dose assessment system was strongly influenced by the ICRP and the U.S. National Council on Radiation Protection and Measurements (NCRP), and is hence consistent with those recommendations. Moreover, the ICRP and FGR both used the scientific data reported by Biological Effects of Ionizing Radiation (BEIR) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) as their primary source of information. The difference between the ICRP and FGR lies in the fact that the ICRP utilized information regarding a population of diverse races, whereas the FGR utilized data on the American population, as its goal was to provide guidelines for radiological protection in the US. The contents of this study are expected to be utilized as basic research material in the areas of radiation protection and dose assessment.

  8. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR

    International Nuclear Information System (INIS)

    Kim, So Ra; Min, Byung Il; Park, Kihyun; Yang, Byung Mo; Suh, Kyung Suk

    2016-01-01

    The International Commission on Radiological Protection (ICRP) recommendations and the Federal Guidance Report (FGR) published by the U.S. Environmental Protection Agency (EPA) have been widely applied worldwide in the fields of radiation protection and dose assessment. The dose conversion coefficients of the ICRP and FGR are widely used for assessing exposure doses. However, before the coefficients are used, the user must thoroughly understand the derivation process of the coefficients to ensure that they are used appropriately in the evaluation. The ICRP provides recommendations to regulatory and advisory agencies, mainly in the form of guidance on the fundamental principles on which appropriate radiological protection can be based. The FGR provides federal and state agencies with technical information to assist their implementation of radiation protection programs for the U.S. population. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR is reviewed in this study. A thorough understanding of their background is essential for the proper use of dose conversion coefficients. The FGR dose assessment system was strongly influenced by the ICRP and the U.S. National Council on Radiation Protection and Measurements (NCRP), and is hence consistent with those recommendations. Moreover, the ICRP and FGR both used the scientific data reported by Biological Effects of Ionizing Radiation (BEIR) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) as their primary source of information. The difference between the ICRP and FGR lies in the fact that the ICRP utilized information regarding a population of diverse races, whereas the FGR utilized data on the American population, as its goal was to provide guidelines for radiological protection in the US. The contents of this study are expected to be utilized as basic research material in the areas of radiation protection and dose assessment

  9. Determination of environmental radioactivity for dose assessment

    International Nuclear Information System (INIS)

    Nakoaka, A.; Fukushima, M.; Takagi, S.

    1980-01-01

    A method was devised to determine detection limits for radioactivity in environmental samples. The method is based on the 5 mrem/yr whole-body dose objective established by the Japan Atomic Enerty Commission and is valid for assessing the internal dose from radionuclides in the environment around a nuclear facility. Eleven samples and 15 radionuclides were considered. Internal dose was assumed to be one-half of the total dose (5 mrem/yr) and was assessed using the critical pathway method. Needed detection limits (NDLs) were established to confirm the dose of 5 mrem/yr when there was more than one radionuclide per sample. The NDLs for γ-emitters were 10 -5 pCi/l. for air; 10 -3 pCi/l. for seawater; 10 -1 pCi/l. for drinking water; 10 0 pCi/kg for vegetables and fish; 10 0 pCi/l. for milk; and 10 1 pCi/kg for molluscs, crustaceans, seaweeds, soil and submarine sediments. The NDLs for β-emitters were 1-1/100 of those for γ-emitters. (author)

  10. A study on the radiation and environmental safety -Development of a real-time radiological dose assessment system-

    Energy Technology Data Exchange (ETDEWEB)

    Han, Moon Heui; Lee, Yung Bok; Kim, Eun Han; Suh, Kyung Suk; Hwang, Won Tae [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    The real-time dose assessment system under development has been updated and the technology for tracer experiment has been established. The calculation of external gamma dose is the most difficult and time-consuming part of the dose calculations. The characteristics of external gamma exposure have been investigated and the method for reducing the calculation time has been devised. The internal exposure via the ingestion of the contaminated foodstuffs is one of the important pathways to the total radiological exposure. In the emergency, it is necessary to take an action such like food ban to protect the internal exposure. An algorithm for the interface between the real-time system and the food chain model has been provided. The second field tracer experiment over flat terrain has been carried out on a plain in Iksan city in Junrabook-Do. Sequential tracer sampler which can be sampled the tracer gas over arbitrary 12 time interval has been designed and manufactured. SF{sub 6} has been used as the tracer gas and the sampled gas has been analysed by gas-chromatographer. 55 figs, 32 tabs, 65 refs. (Author).

  11. Development of computational pregnant female and fetus models and assessment of radiation dose from positron-emitting tracers

    DEFF Research Database (Denmark)

    Xie, Tianwu; Zaidi, H.

    2016-01-01

    /fetus presents a high sensitivity to ionizing radiation. Therefore, estimation of the radiation dose delivered to the embryo/fetus and pregnant patients from PET examinations to assess potential radiation risks is highly praised. Methods: We constructed eight embryo/fetus models at various gestation periods......Purpose: Molecular imaging using PET and hybrid (PET/CT and PET/MR) modalities nowadays plays a pivotal role in the clinical setting for diagnosis and staging, treatment response monitoring, and radiation therapy treatment planning of a wide range of oncologic malignancies. The developing embryo...

  12. Assessments for high dose radionuclide therapy treatment planning

    International Nuclear Information System (INIS)

    Fisher, D.R.

    2003-01-01

    Advances in the biotechnology of cell specific targeting of cancer and the increased number of clinical trials involving treatment of cancer patients with radiolabelled antibodies, peptides, and similar delivery vehicles have led to an increase in the number of high dose radionuclide therapy procedures. Optimised radionuclide therapy for cancer treatment is based on the concept of absorbed dose to the dose limiting normal organ or tissue. The limiting normal tissue is often the red marrow, but it may sometimes be the lungs, liver, intestinal tract, or kidneys. Appropriate treatment planning requires assessment of radiation dose to several internal organs and tissues, and usually involves biodistribution studies in the patient using a tracer amount of radionuclide bound to the targeting agent and imaged at sequential timepoints using a planar gamma camera. Time-activity curves are developed from the imaging data for the major organ tissues of concern, for the whole body and sometimes for selected tumours. Patient specific factors often require that dose estimates be customised for each patient. In the United States, the Food and Drug Administration regulates the experimental use of investigational new drugs and requires 'reasonable calculation of radiation absorbed dose to the whole body and to critical organs' using the methods prescribed by the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine. Review of high dose studies shows that some are conducted with minimal dosimetry, that the marrow dose is difficult to establish and is subject to large uncertainties. Despite the general availability of software, internal dosimetry methods often seem to be inconsistent from one clinical centre to another. (author)

  13. Uncertainty on faecal analysis on dose assessment

    Energy Technology Data Exchange (ETDEWEB)

    Juliao, Ligia M.Q.C.; Melo, Dunstana R.; Sousa, Wanderson de O.; Santos, Maristela S.; Fernandes, Paulo Cesar P. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/n. Via 9, Recreio, CEP 22780-160, Rio de Janeiro, RJ (Brazil)

    2007-07-01

    Monitoring programmes for internal dose assessment may need to have a combination of bioassay techniques, e.g. urine and faecal analysis, especially in workplaces where compounds of different solubilities are handled and also in cases of accidental intakes. Faecal analysis may be an important data for assessment of committed effective dose due to exposure to insoluble compounds, since the activity excreted by urine may not be detectable, unless a very sensitive measurement system is available. This paper discusses the variability of the daily faecal excretion based on data from just one daily collection; collection during three consecutive days: samples analysed individually and samples analysed as a pool. The results suggest that just 1 d collection is not appropriate for dose assessment, since the 24 h uranium excretion may vary by a factor of 40. On the basis of this analysis, the recommendation should be faecal collection during three consecutive days, and samples analysed as a pool, it is more economic and faster. (authors)

  14. External dose assessment in the Ukraine following the Chernobyl accident

    Science.gov (United States)

    Frazier, Remi Jordan Lesartre

    While the physiological effects of radiation exposure have been well characterized in general, it remains unclear what the relationship is between large-scale radiological events and psychosocial behavior outcomes in individuals or populations. To investigate this, the National Science Foundation funded a research project in 2008 at the University of Colorado in collaboration with Colorado State University to expand the knowledge of complex interactions between radiation exposure, perception of risk, and psychosocial behavior outcomes by modeling outcomes for a representative sample of the population of the Ukraine which had been exposed to radiocontaminant materials released by the reactor accident at Chernobyl on 26 April 1986. In service of this project, a methodology (based substantially on previously published models specific to the Chernobyl disaster and the Ukrainian population) was developed for daily cumulative effective external dose and dose rate assessment for individuals in the Ukraine for as a result of the Chernobyl disaster. A software platform was designed and produced to estimate effective external dose and dose rate for individuals based on their age, occupation, and location of residence on each day between 26 April 1986 and 31 December 2009. A methodology was developed to transform published 137Cs soil deposition contour maps from the Comprehensive Atlas of Caesium Deposition on Europe after the Chernobyl Accident into a geospatial database to access these data as a radiological source term. Cumulative effective external dose and dose rate were computed for each individual in a 703-member cohort of Ukrainians randomly selected to be representative of the population of the country as a whole. Error was estimated for the resulting individual dose and dose rate values with Monte Carlo simulations. Distributions of input parameters for the dose assessment methodology were compared to computed dose and dose rate estimates to determine which

  15. Assessment of low absorbed dose with a MOSFET detector

    International Nuclear Information System (INIS)

    Butson, M.J.; Cancer Services, Wollongong, NSW; Cheung, T.; Yu, P.K.N.

    2004-01-01

    Full text: The ability of a MOSFET dosimetry system to measure low therapeutic doses has been evaluated for accuracy for high energy x-ray radiotherapy applications. The MOSFET system in high sensitivity mode produces a dose measurement reproducibility of within 10%, 4% and 2.5% for 2 cGy, 5 cGy and 10cGy dose assessment respectively. This is compared to 7%, 4% and 2% for an Attix parallel plate ionisation chamber and 20%, 7% and 3.5% for a Wellhofer IC4 small volume ionisation chamber. Results for our dose standard thimble ionisation chamber and low noise farmer dosemeter were 2%, 0.5% and 0.25% respectively for these measurements. The quoted accuracy of the MOSFET dosimetry system is partially due to the slight non linear dose response (reduced response) with age of the detector but mainly due to the intrinsic variations in measured voltage differential per applied dose. Results have shown that the MOSFET dosimetry system provides an adequate measure of dose at low dose levels and is comparable in accuracy to the Attix parallel plate ionisation chambers for relative dose assessment at levels of 2cGy to 10cGy. The use of the MOSFET dosimeter at low doses can extend the life expectancy of the device and may provide useful information for areas where low dose assessment is required. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  16. Assessment of external dose indoors in Lithuania

    International Nuclear Information System (INIS)

    Pilkyte, L.; Butkus, D.; Morkunas, G.

    2006-01-01

    The aim of this paper was an assessment of external exposure indoors and its dependence on construction materials and indoor radon concentrations in Lithuanian living houses. Relationship of absorbed dose rate in air indoors and activity indexes of the most commonly used construction materials (wood, concrete and bricks) have been studied using results received in measurements done in >4700 rooms in 1995-2005. Possible connections of dose rate indoors with indoor radon concentrations are also discussed. Findings of this study helped to make an assessment of the mean value of effective dose of Lithuanian population due to external exposure indoors which is equal to 0.58 mSv y -1 . The received data might also be used in improvement of quality of personal dosimetric measurements done in premises constructed of different construction materials. (authors)

  17. Assessment of a new p-Mosfet usable as a dose rate insensitive gamma dose sensor

    International Nuclear Information System (INIS)

    Vettese, F.; Donichak, C.; Bourgeault, P.

    1995-01-01

    Dosimetric response of unbiased MOS devices has been assessed at dose rates greater than 2000 cGy/h. Application have been made to a personal dosemeter / dose rate meter to measure the absorbed tissue dose received in the case of acute external irradiation. (D.L.)

  18. Development of semi-empirical equations for In-water dose distribution using Co-60 beams

    International Nuclear Information System (INIS)

    Abdalla, Siddig Abdalla Talha

    2001-08-01

    Knowledge of absorbed dose distribution is essential for the management of cancer using Co-60 teletherapy. Since direct measurement of dose in patient is impossible, indirect assessments are always carried. In this study direct assessments in phantoms were taken for dose distribution data. Mainly we concentrated on central axis dose and isodose curves data, which are essential for treatment planning. We started by development of a semi-empirical method which uses a more restricted number of measurements and uses graphical relation to develop the dose distribution. This method was based on the decrement lines method which was introduced by Orchard (1964) to develop isodose curve. In the beginning the already developed percent depth dose, Pdd, equation was modified and used to plot the Pdd lines for randomly selected field sizes. After that the dose profiles at depths 5, 10, 15 and 20 cm for randomly selected field sizes were plotted from the direct measurement. Then with the help of the PDD's equation, an equation for the slope of decrement lines is developed. From this slope equation a relation that gives the off axial distance was found. Making use of these relations, the iso lines 80%, 50% and 20% were plotted for the field sizes: 6*6 cm 2 , 10*10 cm 2 and 18*18 cm 2 . Finally these plotted lines were compared to their correspondents from the manufacturer and those used in the hospital (Rick). (Author)

  19. Excipient Usage Technical Risk Assessment for Generic Solid Dose Products

    Directory of Open Access Journals (Sweden)

    Ajay Babu Pazhayattil

    2017-09-01

    Full Text Available This paper proposes an assessment methodology for solid dose generic small molecule drug products. It addresses the ‘usage of the excipient’ portion of the trinomial by utilizing the systematic approach of Risk Identification, Risk Analysis and Risk Evaluation as per ICH Q9 Quality Risk Management outlined for developing risk control strategies. The assessment and maintenance of excipient risk profile is essential to minimize any potential risk associated to excipients impacting patients.

  20. Going beyond the most exposed people in a dose assessment

    Energy Technology Data Exchange (ETDEWEB)

    Hjerpe, Thomas; Broed, Robert [Facilia AB, Gustavslundsvaegen 151C, SE-167 51 Bromma (Sweden); Ikonen, Ari T.K. [Environmental Research and Assessment, EnviroCase, Ltd., Hallituskatu 1 D 4, FI-28 100 Pori (Finland)

    2014-07-01

    The dose assessment in a long-term radiation safety assessment often focus on assessing dose of a representative person to be used for determining compliance with a radiation dose constraint. This representative person is often assumed to receive a dose that is representative of the most exposed people, i.e., the more highly exposed individuals in the population. This is not always sufficient, the Finnish regulations for disposal of nuclear waste has radiation dose constraint to the most exposed people as well as for larger groups of exposed people. This work presents the methodology to assessing dose of a representative person for a larger group of exposed people as applied by Posiva in the TURVA-2012 safety case for the spent nuclear fuel disposal at Olkiluoto. In addition, annual doses from the set of biosphere calculation cases analysed in TURVA-2012 are presented and discussed. Special focus is given on explaining the differences in exposure levels and exposure routes between the estimated annual doses to representative persons for most exposed people and a larger exposed group. The results show that the annual doses to a larger group of people ranges from one to three orders of magnitude below the annual doses to the most exposed people. Furthermore, the exposure route related to food ingestion is less significant for the larger group of people compared to the most exposed people and that the exposure route related to water ingestion shows the opposite behaviour. (authors)

  1. Dose. Detriment. Limit assessment

    International Nuclear Information System (INIS)

    Breckow, J.

    2015-01-01

    One goal of radiation protection is the limitation of stochastic effects due to radiation exposure. The probability of occurrence of a radiation induced stochastic effect, however, is only one of several other parameters which determine the radiation detriment. Though the ICRP-concept of detriment is a quantitative definition, the kind of detriment weighting includes somewhat subjective elements. In this sense, the detriment-concept of ICRP represents already at the stage of effective dose a kind of assessment. Thus, by comparing radiation protection standards and concepts interconvertible or with those of environment or occupational protection one should be aware of the possibly different principles of detriment assessment.

  2. Guidelines for application of chemical-specific adjustment factors in dose/concentration-response assessment

    International Nuclear Information System (INIS)

    Meek, M.E.; Renwick, A.; Ohanian, E.; Dourson, M.; Lake, B.; Naumann, B.D.; Vu, V.

    2002-01-01

    This manuscript addresses guidance in the use of kinetic and dynamic data to inform quantitatively extrapolations for interspecies differences and human variability in dose-response assessment developed in a project of the International Programme on Chemical Safety (IPCS) initiative on Harmonisation of Approaches to the Assessment of Risk from Exposure to Chemicals. The guidance has been developed and refined through a series of planning and technical meetings and larger workshops of a broad range of participants from academia, government agencies and the private sector. The guidance for adequacy of data for replacement of common defaults for interspecies differences and human variability is presented in the context of several generic categories including: determination of the active chemical species, choice of the appropriate metric (kinetic components) or endpoint (dynamic components) and nature of experimental data, the latter which includes reference to the relevance of population, route and dose and the adequacy of the number of subjects/samples. The principal objective of this guidance developed primarily as a resource for risk assessors, is to foster better understanding of the components of and criteria for adequacy of chemical-specific data to quantitate interspecies differences and human variability in kinetics and dynamics. It is anticipated that this guidance will also encourage the development of appropriate data and facilitate their incorporation in a consistent fashion in dose-response assessment for regulatory purposes (IPCS, 2001)

  3. Assessment of concomitant testicular dose with radiochromic film

    International Nuclear Information System (INIS)

    Fricker, Katherine; Thompson, Christine; Meyer, Juergen

    2013-01-01

    To assess the suitability of EBT2 and XRQA2 Gafchromic film for measuring low doses in the periphery of treatment fields, and to measure the accumulative concomitant dose to the contralateral testis resulting from CT imaging, pre-treatment imaging (CBCT) and seminoma radiotherapy with and without gonadal shielding. Superficial peripheral dose measurements made using EBT2 Gafchromic film on the surface of water equivalent material were compared to measurements made with an ionisation chamber in a water phantom to evaluate the suitability and accuracy of the film dosimeter for such measurements. Similarly, XRQA2 was used to measure surface doses within a kilovoltage beam and compared with ionisation chamber measurements. Gafchromic film was used to measure CT, CBCT and seminoma treatment related testicular doses on an anthropomorphic phantom. Doses were assessed for two clinical plans, both with and without gonadal shielding. Testicular doses resulting from the treatment of up to 0.83 ± 0.17 Gy were measured per treatment. Additional doses of up to 0.49 ± 0.01 and 2.35 ± 0.05 cGy were measured per CBCT and CT image, respectively. Reductions in the testicular dose in the order of 10, 36 and 78 % were observed when gonadal shielding was fitted for treatment, CT and CBCT imaging, respectively. Gafchromic film was found to be suitable for measuring dose in the periphery of treatment fields. The dose to the testis should be limited to minimise the risk of radiation related side effects. This can be achieved by using appropriate gonadal shielding, irrespective of the treatment fields employed.

  4. New technology development for radiation dose measurement and evaluation based on the operational quantity

    International Nuclear Information System (INIS)

    Kim, Jang Lyul; Kim, B. H.; Lee, J. I.; Lim, K. S.; Song, M. Y.; Joo, G. S.; Kim, S. I.; Chang, I. S.

    2012-04-01

    · Development of optically stimulated luminescence (OSL) technique for multi-purpose radiation dosimetry - Development of a semi-automatic type OSL measurement system · Number of sample holders: 10 ea · Development of a built-in type reference radiation irradiation system using 50 kV-1 mA X-rays of the maximum dose rate of 230 mGy/s - Development of an automatic diameter control system and crystal growth system for making a new OSL material: LiMgF 3 : X, LiAlO 2 : C - Development of a procedure of retrospective accident dosimetry · Establishment of Practical Technology for Internal Dose Assessment - Development of the technology to the internal dose assessment for an injection of radionuclides and intercomparison on the evaluation results of the committed effective dose between the estimators of Korea · Construction of workplace monitoring technique by quantification of neutron fields - Preparation of the neutron spectra DB of various neutron fields and production of those dosimetric data: 29 kinds of neutron fields using a thermal neutron irradiator, a proton accelerator and a neutron generator - Neutron monitoring procedure at workplace using neutron fluence spectra

  5. Thermoluminescent dosimetry and assessment of personal dose

    International Nuclear Information System (INIS)

    Boas, J.F.; Martin, L.J.; Young, J.G.

    1982-01-01

    Thermoluminescence is discussed in terms of the energy band structure of a crystalline solid and the trapping of charge carriers by point defects. Some general properties of thermoluminescent materials used for dosimetry are outlined, with thermoluminescence of CaSO 4 :Dy being described in detail. The energy response function and the modification of the energy response of a dosimeter by shielding are discussed. The final section covers the connection between exposure, as recorded by a TLD badge, and the absorbed dose to various organs from gamma radiation in a uranium mine; the conversion from absorbed dose to dose equivalent; and uncertainties in assessment of dose equivalent

  6. Iodine-129 Dose in LLW Disposal Facility Performance Assessments

    International Nuclear Information System (INIS)

    Wilhite, E.L.

    1999-01-01

    Iodine-129 has the lowest Performance Assessment derived inventory limit in SRS disposal facilities. Because iodine is concentrated in the body to one organ, the thyroid, it has been thought that dilution with stable iodine would reduce the dose effects of 129I.Examination of the dose model used to establish the Dose conversion factor for 129I shows that, at the levels considered in performance assessments of low-level waste disposal facilities, the calculated 129I dose already accounts for ingestion of stable iodine. At higher than normal iodine ingestion rates, the uptake of iodine by the thyroid itself decrease, which effectively cancels out the isotopic dilution effect

  7. Technical Note: SCUDA: A software platform for cumulative dose assessment

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seyoun; McNutt, Todd; Quon, Harry; Wong, John; Lee, Junghoon, E-mail: rshekhar@childrensnational.org, E-mail: junghoon@jhu.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland 21231 (United States); Plishker, William [IGI Technologies, Inc., College Park, Maryland 20742 (United States); Shekhar, Raj, E-mail: rshekhar@childrensnational.org, E-mail: junghoon@jhu.edu [IGI Technologies, Inc., College Park, Maryland 20742 and Sheikh Zayed Institute for Pediatric Surgical Innovation, Children’s National Health System, Washington, DC 20010 (United States)

    2016-10-15

    Purpose: Accurate tracking of anatomical changes and computation of actually delivered dose to the patient are critical for successful adaptive radiation therapy (ART). Additionally, efficient data management and fast processing are practically important for the adoption in clinic as ART involves a large amount of image and treatment data. The purpose of this study was to develop an accurate and efficient Software platform for CUmulative Dose Assessment (SCUDA) that can be seamlessly integrated into the clinical workflow. Methods: SCUDA consists of deformable image registration (DIR), segmentation, dose computation modules, and a graphical user interface. It is connected to our image PACS and radiotherapy informatics databases from which it automatically queries/retrieves patient images, radiotherapy plan, beam data, and daily treatment information, thus providing an efficient and unified workflow. For accurate registration of the planning CT and daily CBCTs, the authors iteratively correct CBCT intensities by matching local intensity histograms during the DIR process. Contours of the target tumor and critical structures are then propagated from the planning CT to daily CBCTs using the computed deformations. The actual delivered daily dose is computed using the registered CT and patient setup information by a superposition/convolution algorithm, and accumulated using the computed deformation fields. Both DIR and dose computation modules are accelerated by a graphics processing unit. Results: The cumulative dose computation process has been validated on 30 head and neck (HN) cancer cases, showing 3.5 ± 5.0 Gy (mean±STD) absolute mean dose differences between the planned and the actually delivered doses in the parotid glands. On average, DIR, dose computation, and segmentation take 20 s/fraction and 17 min for a 35-fraction treatment including additional computation for dose accumulation. Conclusions: The authors developed a unified software platform that provides

  8. Dose assessment, radioecology, and community interaction at former nuclear test sites

    International Nuclear Information System (INIS)

    Robison, W.L.

    1994-11-01

    The US conducted a nuclear testing program at Bikini and Enewetak Atolls in the Marshall Islands from 1946 through 1958. A total of 66 nuclear devices were tested--23 at Bikini Atoll (total yield of 77 megatons) and 43 at Enewetak Atoll (total yield of 33 megatons). This resulted in contamination of many of the islands at each atoll. The BRAVO test (yield 15 megatons) on March 1, 1954 contaminated several atolls to the east of Bikini Atoll some of which were inhabited. The author has conducted an experimental, monitoring, and dose assessment program at atolls in the northern Marshall Islands for the past 20 years. The goals have been to: (1) determine the radiological conditions at the atolls; (2) provide dose assessments for resettlement options and alternate living patterns; (3) develop and evaluate remedial measures to reduce the dose to people reinhabiting the atolls; and (4) discuss the results with each of the communities and the Republic of the Marshall Islands government officials to help them understand the data as a basis for resettlement decisions. The remaining radionuclides at the atolls that contribute any significant dose are 137 Cs, 90 Sr, 239+240 Pu, and 241 Am

  9. Relationship between dose and risk, and assessment of carcinogenic risks associated with low doses of ionizing radiation

    International Nuclear Information System (INIS)

    Tubiana, M.; Aurengo, A.

    2005-01-01

    This report raises doubts on the validity of using LNT (linear no-threshold) relationship for evaluating the carcinogenic risk of low doses (< 100 mSv) and even more for very low doses (< 10 mSv). The LNT concept can be a useful pragmatic tool for assessing rules in radioprotection for doses above 10 mSv; however since it is not based on biological concepts of our current knowledge, it should not be used without precaution for assessing by extrapolation the risks associated with low and even more so, with very low doses (< 10 mSv), especially for benefit-risk assessments imposed on radiologists by the European directive 97-43. The biological mechanisms are different for doses lower than a few dozen mSv and for higher doses. The eventual risks in the dose range of radiological examinations (0.1 to 5 mSv, up to 20 mSv for some examinations) must be estimated taking into account radiobiological and experimental data. An empirical relationship which has been just validated for doses higher than 200 mSv may lead to an overestimation of risks (associated with doses one hundred fold lower), and this overestimation could discourage patients from undergoing useful examinations and introduce a bias in radioprotection measures against very low doses (< 10 mSv). Decision makers confronted with problems of radioactive waste or risk of contamination, should re-examine the methodology used for the evaluation of risks associated with very low doses and with doses delivered at a very low dose rate. This report confirms the inappropriateness of the collective dose concept to evaluate population irradiation risks

  10. Recent developments in carcinogenic risk assessment

    International Nuclear Information System (INIS)

    Krewski, D.; Murdoch, D.; Withey, J.R.

    1989-01-01

    In this paper, recent developments in the quantitative assessment of carcinogenic risks based on toxicological and epidemiological data are reviewed. In particular, model-free approaches to low-dose risk assessment which involve only the assumption of low-dose linearity are considered. Measures of carcinogenic potency which avoid the need to extrapolate to low doses are also described. The allometric bases for converting risk estimates between species are then discussed. Pharmacokinetic models for determining the dose delivered to the target tissue are examined, and the implications of using such models in extrapolating between doses, of exposure, and species are examined. The application of these concepts in chemical and radiation carcinogenesis is illustrated by means of brief case studies of methylene chloride and Rn. Biologically motivated cancer models based on the initiation-promotion-progression theory of carcinogenesis are discussed and compared with the classical multistage model. The estimation of risks with time-dependent exposure patterns is considered, and conditions under which the use of a time-weighted average dose is appropriate are identified. Finally, the estimation of carcinogenic risks posed by exposure to complex mixtures is explored. 92 references

  11. Improvement of Off-site Dose Assessment Code for Operating Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Juyub; Kim, Juyoul; Shin, Kwangyoung [FNC Technology Co. Ltd., Yongin (Korea, Republic of); You, Songjae; Moon, Jongyi [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2014-05-15

    XOQDOQ code which calculates atmospheric Dispersion factor was included into INDAC also. A research on the improvement of off-site dose assessment system for an operating nuclear power plant was performed by KINS in 2011. As a result, following improvements were derived: - Separation of dose assessment for new and existing facilities - Update of food ingestion data - Consideration of multi-unit operation and so on In order to reflect the results, INDAC is under modification. INDAC is an integrated dose assessment code for an operating nuclear power plant and consists of three main modules: XOQDOQ, GASDOS and LIQDOS. The modules are under modification in order to improve the accuracy of assessment and usability. Assessment points for multi-unit release can be calculated through the improved code and the method on dose assessment for multi-unit release has been modified, so that the dose assessment result of multi-unit site becomes more realistic by relieving excessive conservatism. Finally, as the accuracy of calculation modules has been improved, the reliability of dose assessment result has been strengthened.

  12. Technical basis for using nose swab bioassay data for early internal dose assessment

    International Nuclear Information System (INIS)

    Guilmette, Raymond A.; Bertelli, Luiz; Miller, Guthrie; Little, Tom T.

    2007-01-01

    One of the challenges to the dose assessment team in response to an inhalation incident in the workplace is to provide the occupational physicians, operational radiation protection personnel and line managers with early estimates of radionuclide intakes so that appropriate consequence management and mitigation can be done. For radionuclides such as Pu, where in vivo counting is not adequately sensitive, other techniques such as the measurement of removable radionuclide from the nasal airway passages can be used. At Los Alamos National Laboratory (LANL), nose swabs of the ET 1 region have been used routinely as a first response to airborne Pu releases in the workplace, as well as for other radionuclides. This paper presents the results of analysing over 15 years of nose swab data, comparing these with dose assessments performed using the Bayesian methods developed at LANL. The results provide empirical support for using nose swab data for early dose assessments. For Pu, a rule of thumb is a dose factor of 0.8 mSv Bq -1 , assuming a linear relationship between nasal swab activity and committed effective dose equivalent. However, this value is specific to the methods and models used at LANL, and should not be applied directly without considering possible differences in measurement and calculation methods. (authors)

  13. Personal monitoring and assessment of doses received by radiation workers

    International Nuclear Information System (INIS)

    Swindon, T.N.; Morris, N.D.

    1981-12-01

    The Personal Radiation Monitoring Service operated by the Australian Radiation Laboratory is outlined and the types of monitors used for assessment of doses received by radiation workers are described. The distribution of doses received by radiation workers in different occupational categories is determined. From these distributions, the average doses received have been assessed and the maximum likely additional increase in cancer deaths in Australia as a result of occupational exposure estimated. This increase is shown to be very small. There is, however, a considerable spread of doses received by individuals within occupational groups

  14. Construction of average adult Japanese voxel phantoms for dose assessment

    International Nuclear Information System (INIS)

    Sato, Kaoru; Takahashi, Fumiaki; Satoh, Daiki; Endo, Akira

    2011-12-01

    The International Commission on Radiological Protection (ICRP) adopted the adult reference voxel phantoms based on the physiological and anatomical reference data of Caucasian on October, 2007. The organs and tissues of these phantoms were segmented on the basis of ICRP Publication 103. In future, the dose coefficients for internal dose and dose conversion coefficients for external dose calculated using the adult reference voxel phantoms will be widely used for the radiation protection fields. On the other hand, the body sizes and organ masses of adult Japanese are generally smaller than those of adult Caucasian. In addition, there are some cases that the anatomical characteristics such as body sizes, organ masses and postures of subjects influence the organ doses in dose assessment for medical treatments and radiation accident. Therefore, it was needed to use human phantoms with average anatomical characteristics of Japanese. The authors constructed the averaged adult Japanese male and female voxel phantoms by modifying the previously developed high-resolution adult male (JM) and female (JF) voxel phantoms. It has been modified in the following three aspects: (1) The heights and weights were agreed with the Japanese averages; (2) The masses of organs and tissues were adjusted to the Japanese averages within 10%; (3) The organs and tissues, which were newly added for evaluation of the effective dose in ICRP Publication 103, were modeled. In this study, the organ masses, distances between organs, specific absorbed fractions (SAFs) and dose conversion coefficients of these phantoms were compared with those evaluated using the ICRP adult reference voxel phantoms. This report provides valuable information on the anatomical and dosimetric characteristics of the averaged adult Japanese male and female voxel phantoms developed as reference phantoms of adult Japanese. (author)

  15. Development of a neutron personal dose equivalent detector

    International Nuclear Information System (INIS)

    Tsujimura, N.; Yoshida, T.; Takada, C.; Momose, T.; Nunomiya, T.; Aoyama, K.

    2007-01-01

    A new neutron-measuring instrument that is intended to measure a neutron personal dose equivalent, H p (10) was developed. This instrument is composed of two parts: (1) a conventional moderator-based neutron dose equivalent meter and (2) a neutron shield made of borated polyethylene, which covers a backward hemisphere to adjust the angular dependence. The whole design was determined on the basis of MCNP calculations so as to have response characteristics that would generally match both the energy and angular dependencies of H p (10). This new instrument will be a great help in assessing the reference values of neutron H p (10) during field testing of personal neutron dosemeters in workplaces and also in interpreting their readings. (authors)

  16. Dose assessment activities in the Republic of the Marshall Islands

    International Nuclear Information System (INIS)

    Simon, S.L.; Graham, J.C.

    1996-01-01

    Dose assessments, both retrospective and prospective, comprise one important function of a radiological study commissioned by the Republic of the Marshall Islands (RMI) government in late 1989. Estimating past or future exposure requires the synthesis of information from historical data, results from a recently completed field monitoring program, laboratory measurements, and some experimental studies. Most of the activities in the RMI to date have emphasized a pragmatic rather than theoretical approach. In particular, most of the recent effort has been expended on conducting an independent radiological monitoring program to determine the degree of deposition and the geographical extent of weapons test fallout over the nation. Contamination levels on 70% of the land mass of the Marshall Islands were unknown prior to 1994. The environmental radioactivity data play an integral role in both retrospective and prospective assessments. One recent use of dose assessment has been to interpret environmental measurements of radioactivity into annual doses that might be expected at every atoll. A second use for dose assessment has been to determine compliance with dose action level for the rehabitation of Rongelap Island. Careful examination of exposure pathways relevant to the island lifestyle has been necessary to accommodate these purposes. Finally, an examination is underway of gummed film, fixed-instrument, and aerial survey data accumulated during the 1950's by the Health and Safety Laboratory of the U.S. AEC. This article gives an overview of these many different activities and a summary of recent dose assessments

  17. Assessment of prospective foodchain doses from radioactive discharges from BNFL Sellafield

    International Nuclear Information System (INIS)

    Ould-Dada, Z.; Tucker, S.; Webbe-Wood, D.; Mondon, K.; Hunt, J.

    2002-01-01

    This paper presents the method used by the UK Food Standards Agency (FSA) to assess the potential impact of proposed radioactive discharges from the Sellafield nuclear site on food and determine their acceptability. It explains aspects of a cautious method that has been adopted to reflect the UK government policy and uncertainties related to people's habits with regard to food production and consumption. Two types of ingestion doses are considered in this method: 'possible' and 'probable' doses. The method is specifically applied to Sellafield discharge limits and calculated possible and probable ingestion doses are presented and discussed. Estimated critical group ingestion doses are below the dose limit and constraint set for members of the public. The method may be subject to future amendments to take account of changes in government policy and the outcome of a recent Consultative Exercise on Dose Assessments carried out by FSA. Uncertainties inherent in dose assessments are discussed and quantified wherever possible

  18. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer; Avaliacao da dose no reto em pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do cancer do colo uterino

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Jetro Pereira de [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina; Rosa, Luiz Antonio Ribeiro da [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)], e-mail: lrosa@ird.gov.br; Batista, Delano Valdivino Santos; Bardella, Lucia Helena [Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ (Brazil). Unit of Medical Physics; Carvalho, Arnaldo Rangel [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. of Thermoluminescent Dosimetry

    2009-03-15

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  19. Study on dose assessment in surrounding environment of the Tono Mine associated with closure activity

    International Nuclear Information System (INIS)

    Sasao, Eiji

    2012-07-01

    Dose assessment associated with closure activity of the Tono Mine has been performed. In this assessment, exposure dose has been calculated on groundwater and surface water migration of radionuclide from 1) waste rock in the waste rock dump facility, 2) mining waste in the mining waste facility, and 3) uranium ore and waste rock backfilled in the shafts and galleries. Direct and skyshine gamma rays and exposure of exhalated radon from the waste rock dump has also been evaluated. An evaluation tool developed for safety assessment for sub-surface disposal of radioactive waste is utilized for this assessment. Localities for dose evaluation are selected at the Higashihoragawa and Hiyoshigawa based on the topography around the Tono Mine and groundwater flow simulation. Evaluation scenarios are classified into 'Scenario for intake of agricultural product' as the base scenario, and 'Scenario for intake of groundwater' as the alternative scenario. Parameters for dose assessment are set-up based on the existing data. But the range and uncertainty of parameters are taken into account in the 'alternative cases'. As the result of dose assessment, maximum exposure dose of the base scenario is 0.08mSv/year, and 0.09mSv/year including direct and skyshine gamma rays and exposure of exhalatedradon at the Higashihoragawa. Maximum exposure dose of the alternative scenario is 0.08mSv/year (0.09mSv/year including direct and skyshine gamma rays and exposure of exhalated radon). On the alternative cases, exposure doses are calculated as 0.05-0.14mSv/year in both of the base and alternative scenarios. At the Hiyoshigawa, maximum exposure dose is less than 0.001mSv/year (1x10 -6 mSv/year) for the base scenario, and 0.001mSv/year for the alternative scenario. On the alternative cases, maximum exposure doses are less than 0.001mSv/year for all cases of the base scenario and 0.0006-0.002mSv/year for the alternative scenario. (author)

  20. Guidance on internal dose assessments from monitoring data (Project IDEAS)

    International Nuclear Information System (INIS)

    Doerfel, H.; Andrasi, A.; Bailey, M.; Berkovski, V.; Castellani, M.; Hurtgen, C.; Jourdain, R.; Le Guen, B.

    2003-01-01

    Several international intercomparison exercises on intake and internal dose assessments from monitoring data led to the conclusion that the results calculated by different participants varied significantly mainly to the broad variety of methods and assumptions applied in the assessment procedure. Based on these experiences the need of harmonisation of the procedures has been formulated as an EU research project under the 5th Framework Programme, with the aim of developing general guidelines for standardising assessments of intakes and internal doses. In the IDEAS project, eight institutions from seven European countries are participating, also using inputs from internal dosimetry professionals from across Europe to ensure broad consensus in the outcome of the project. To ensure that the guidelines are applicable to a wide range of practical situations, the first step will be to compile a database on well documented cases of internal contamination. In parallel, an improved version of existing software will be developed and distributed to the partners for further use. Many cases from the database will be evaluated independently by more partners using the same software and the results will be discussed and the draft guidelines prepared. The guidelines will then be revised and refined on the basis of the experiences and discussions of two workshops, and an inter-comparison exercise organised in the frame of the project which will be open to all internal dosimetry professionals. (author)

  1. Design, implementation and verification of software code for radiation dose assessment based on simple generic environmental model

    International Nuclear Information System (INIS)

    I Putu Susila; Arif Yuniarto

    2017-01-01

    Radiation dose assessment to determine the potential of radiological impacts of various installations within nuclear facility complex is necessary to ensure environmental and public safety. A simple generic model-based method for calculating radiation doses caused by the release of radioactive substances into the environment has been published by the International Atomic Energy Agency (IAEA) as the Safety Report Series No. 19 (SRS-19). In order to assist the application of the assessment method and a basis for the development of more complex assessment methods, an open-source based software code has been designed and implemented. The software comes with maps and is very easy to be used because assessment scenarios can be done through diagrams. Software verification was performed by comparing its result to SRS-19 and CROM software calculation results. Dose estimated by SRS-19 are higher compared to the result of developed software. However, these are still acceptable since dose estimation in SRS-19 is based on conservative approach. On the other hand, compared to CROM software, the same results for three scenarios and a non-significant difference of 2.25 % in another scenario were obtained. These results indicate the correctness of our implementation and implies that the developed software is ready for use in real scenario. In the future, the addition of various features and development of new model need to be done to improve the capability of software that has been developed. (author)

  2. Development of methodology for assessment of absorbed dose and stopping power for low energy conversion electrons

    International Nuclear Information System (INIS)

    Almeida, Ivan Pedro Salati de

    1995-08-01

    The evaluation of absorbed dose in the case of external and internal contamination due to radionuclides is sometimes hard, because of the difficulties in the assessment of the absorbed dose caused by electrons with energy less than 100 KeV in mucous membrane. In this work, a methodology for assessment of absorbed dose and stopping power in VYNS (co-polymer of polivinyl chloride - acetate) absorbers, for the 62.5 KeV and 84-88 KeV energy 109 Cd conversion electrons, working with a 4 π proportional pressurized detector, is presented. In order to assure the reproducibility of measurement conditions, one of the detector halves has been used to obtain a spectrum of a thin 109 Cd source, without absorber. The other half of the detector was used in concomitance to obtain spectra with different thicknesses if absorber. The absorbed energy was obtained subtracting each spectrum with absorber from the spectrum without absorber, which were stored in a microcomputer connected to signal processing systems by ACE type interface. The VYNS weight and thickness were evaluated using common radionuclide metrology procedures. As VYNS has characteristics similar to a tissue equivalent material, the results obtained are consistent with dosimetric concepts and have a good agreement with those of the literature. (author)

  3. Mesorad dose assessment model. Volume 1. Technical basis

    International Nuclear Information System (INIS)

    Scherpelz, R.I.; Bander, T.J.; Athey, G.F.; Ramsdell, J.V.

    1986-03-01

    MESORAD is a dose assessment model for emergency response applications. Using release data for as many as 50 radionuclides, the model calculates: (1) external doses resulting from exposure to radiation emitted by radionuclides contained in elevated or deposited material; (2) internal dose commitment resulting from inhalation; and (3) total whole-body doses. External doses from airborne material are calculated using semi-infinite and finite cloud approximations. At each stage in model execution, the appropriate approximation is selected after considering the cloud dimensions. Atmospheric processes are represented in MESORAD by a combination of Lagrangian puff and Gaussian plume dispersion models, a source depletion (deposition velocity) dry deposition model, and a wet deposition model using washout coefficients based on precipitation rates

  4. Computerized assessment of the measurement of individual doses

    International Nuclear Information System (INIS)

    Kiibus, A.

    1981-06-01

    The department for the measurements of individual doses makes regular dose controls by means of film badges for approximately 14000 individuals. The operation is facilitated by a Honeywell Bull Mini 6 Mod 43 computer. The computer language is COBOL applied to registering of in-data such as delivery of badges, film development, calibration, invoices, recording of individual doses and customers. The print-out consists of customers, badge codes, dosimeter lists, development specifications, dose statements, addresses, bills, dose statistics and the register of individuals. As a consequence of charges the activity is financially self-supporting. (G.B.)

  5. Human intruder dose assessment for deep geological disposal

    International Nuclear Information System (INIS)

    Smith, G. M.; Molinero, J.; Delos, A.; Valls, A.; Conesa, A.; Smith, K.; Hjerpe, T.

    2013-07-01

    For near-surface disposal, approaches to assessment of inadvertent human intrusion have been developed through international cooperation within the IAEA's ISAM programme. Other assessments have considered intrusion into deep geological disposal facilities, but comparable international cooperation to develop an approach for deep disposal has not taken place. Accordingly, the BIOPROTA collaboration project presented here (1) examined the technical aspects of why and how deep geological intrusion might occur; (2) considered how and to what degree radiation exposure would arise to the people involved in such intrusion; (3) identified the processes which constrain the uncertainties; and hence (4) developed and documented an approach for evaluation of human intruder doses which addresses the criteria adopted by the IAEA and takes account of other international guidance and human intrusion assessment experience. Models for radiation exposure of the drilling workers and geologists were developed and described together with compilation of relevant input data, taking into account relevant combinations of drilling technique, geological formation and repository material. Consideration has been given also to others who might be exposed to contaminated material left at the site after drilling work has ceased. The models have been designed to be simple and stylised, in accordance with international recommendations. The set of combinations comprises 58 different scenarios which cover a very wide range of human intrusion possibilities via deep drilling. (orig.)

  6. Utilization of dose assessment models to facilitate off-site recovery operations for accidents at nuclear facilities

    International Nuclear Information System (INIS)

    Dickerson, M.H.; Foster, K.T.

    1989-09-01

    One of the most important uses of dose assessment models in response to accidents at nuclear facilities is to help provide guidance to emergency response managers for identifying, and mitigating, the consequences of an accident once the accident has been terminated. By combining results from assessment models with radiological measurements, a qualitative methodology can be developed to aid emergency response managers in determining the total dose received by the population and to minimize future doses through the use of mitigation procedures. To illustrate the methodology, this discussion focuses on the use of models to estimate the dose delivered to the public both during and after a nuclear accident. 4 refs., 10 figs., 1 tab

  7. Assessment of population external irradiation doses with consideration of Rospotrebnadzor bodies equipment for monitoring of photon radiation dose

    Directory of Open Access Journals (Sweden)

    I. P. Stamat

    2016-01-01

    Full Text Available This paper provides review of equipment and methodology for measurement of photon radiation dose; analysis of possible reasons for considerable deviation between the Russian Federation population annual effective external irradiation doses and the relevant average global value. Data on Rospotrebnadzor bodies dosimetry equipment used for measurement of gamma radiation dose are collected and systematized. Over 60 kinds of dosimeters are used for monitoring of population external irradiation doses. Most of dosimeters used in the country have gas-discharge detectors (Geiger-Mueller counters, minor biochemical annunciators, etc. which have higher total values of own background level and of space radiation response than the modern dosimeters with scintillation detectors. This feature of dosimeters is apparently one of most plausible reasons of a bit overstating assessment of population external irradiation doses. The options for specification of population external irradiation doses assessment are: correction of gamma radiation dose measurement results with consideration of dosimeters own background level and space radiation response, introduction of more up-to-date dosimeters with scintillation detectors, etc. The most promising direction of research in verification of population external irradiation doses assessment is account of dosimetry equipment.

  8. Research and assessment of national population dose

    International Nuclear Information System (INIS)

    Pan Ziqiang

    1984-01-01

    This article describes the necessity and probability of making researches on assessment of national population dose, and discusses some problems which might be noticeable in the research work. (author)

  9. Review of calculational models and computer codes for environmental dose assessment of radioactive releases

    International Nuclear Information System (INIS)

    Strenge, D.L.; Watson, E.C.; Droppo, J.G.

    1976-06-01

    The development of technological bases for siting nuclear fuel cycle facilities requires calculational models and computer codes for the evaluation of risks and the assessment of environmental impact of radioactive effluents. A literature search and review of available computer programs revealed that no one program was capable of performing all of the great variety of calculations (i.e., external dose, internal dose, population dose, chronic release, accidental release, etc.). Available literature on existing computer programs has been reviewed and a description of each program reviewed is given

  10. Review of calculational models and computer codes for environmental dose assessment of radioactive releases

    Energy Technology Data Exchange (ETDEWEB)

    Strenge, D.L.; Watson, E.C.; Droppo, J.G.

    1976-06-01

    The development of technological bases for siting nuclear fuel cycle facilities requires calculational models and computer codes for the evaluation of risks and the assessment of environmental impact of radioactive effluents. A literature search and review of available computer programs revealed that no one program was capable of performing all of the great variety of calculations (i.e., external dose, internal dose, population dose, chronic release, accidental release, etc.). Available literature on existing computer programs has been reviewed and a description of each program reviewed is given.

  11. Assessment and recording of radiation doses to workers

    International Nuclear Information System (INIS)

    1986-01-01

    The assessment and recording of the radiation exposure of workers in activities involving radiation risks are required for demonstrating compliance with institutional dose limitations and for a number of other complementary purposes. A significant proportion of the labor force involved in radiation work is currently represented by those specialised workers who operate as itinerant contractors for different nuclear installations and in different countries. In order to ensure that the exposure of these workers is adequately and consistently controlled and kept within acceptable limits, there is a need for the criteria and methods for dose assessment and recording to be harmonised throughout the different countries. An attempt in that direction has been made in this report, which has been prepared by a group of experts convened by the Committee on Radiation Protection and Public Health of the OECD Nuclear Energy Agency. Its primary purpose is to describe recommended technical procedures for an unified approach to the assessment and recording of worker doses. The report is published under the responsibility of the Secretary-General of the OECD, and does not commit Member governments

  12. Dose assessment under incidental and accidental conditions

    International Nuclear Information System (INIS)

    Huebschmann, W.G.

    1988-01-01

    Dose assessment for the licesing process of a nuclear power plant covers the routine release of radioactive substances into the atmosphere as well as releases due to incidents. Source terms for these incidents are evaluated by the detailed incident analysis of the plant. The types of incidents to be covered are determined in the FRG by the ''Stoerfall-Leitlinien'' of the Ministry of the Interior. The calculation of dose equivalents in the environment of the plant differs from the calculation of doses due to routine releases, as incidents are single events occuring at undeterminate time, and the results must be conservative. Some details are being described. During the operation of the plant it is essential to measure not only the radioactivity release rates but also the necessary meteorological parameters for the instantaneous determination of the atmospheric dispersion in case of incidental or accidental releases of radioactivity. This instantaneous assessment assists in taking measurements of ground contamination and in deciding about countermeasures for the protection of plant personnell and population. (author) [pt

  13. Skin dose assessment in routine personnel beta/gamma dosimetry

    International Nuclear Information System (INIS)

    Christensen, P.

    1980-01-01

    The International Commission on Radiological Protection (Publication 26) has recommended a tissue depth of 5 to 10 mg.cm -2 for skin dose assessments. This requirement is generally not fulfilled by routine monitoring procedures because of practical difficulties in using very thin dosemeters with low sensitivity and therefore a high minimum detectable dose. Especially for low-energy beta-ray exposures underestimations of the skin dose by a factor of more than ten may occur. Low-transparent graphite-mixed sintered LiF and Li 2 B 4 0 7 : Mn dosemeters were produced which show a skin-equivalent response to beta and gamma exposures over a wide range of energies. These have found wide-spread application for extremity dosimetry but have not yet been generally introduced in routine personnel beta/gamma monitoring. The following adaptations of existing routine monitoring systems for improved skin dose assessments have been investigated: 1) Placement of a supplementary, thin, skin-dose equivalent dosemeter in the TLD badge to give additional information on low-energy exposures. 2) Introduction of a second photomultiplier in the read-out chamber which enables a simultaneous determination of emitted TL from both sides of the dosemeter separately. This method makes use of the selfshielding of the dosemeter to give information on the low-energy dose contribution. 3) By diffusion of Li 2 B 4 0 7 into solid LiF-dosemeters it was possible to produce a surface layer with a new distinct glow-peak at about 340 deg C which is not present in the undiffused part of the LiF chip, and which can be utilized for the assessment of the skin-dose. Data on energy response and accuracy of dose measurement for beta/gamma exposures are given for the three methods and advantages and disadvantages are discussed (H.K.)

  14. Internal Dose Conversion Coefficients of Domestic Reference Animal and Plants for Dose Assessment of Non-human Species

    International Nuclear Information System (INIS)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Choi, Yong Ho

    2009-01-01

    Traditionally, radiation protection has been focused on a radiation exposure of human beings. In the international radiation protection community, one of the recent key issues is to establish the methodology for assessing the radiological impact of an ionizing radiation on non-human species for an environmental protection. To assess the radiological impact to non-human species dose conversion coefficients are essential. This paper describes the methodology to calculate the internal dose conversion coefficient for non-human species and presents calculated internal dose conversion coefficients of 25 radionuclides for 8 domestic reference animal and plants

  15. Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality

    International Nuclear Information System (INIS)

    Habib Geryes, Bouchra; Calmon, Raphael; Boddaert, Nathalie; Khraiche, Diala; Bonnet, Damien; Raimondi, Francesca

    2016-01-01

    To assess the impact of different protocols on radiation dose and image quality for paediatric coronary computed tomography (cCT). From January-2012 to June-2014, 140 children who underwent cCT on a 64-slice scanner were included. Two consecutive changes in imaging protocols were performed: 1) the use of adaptive statistical iterative reconstruction (ASIR); 2) the optimization of acquisition parameters. Effective dose (ED) was calculated by conversion of the dose-length product. Image quality was assessed as excellent, good or with significant artefacts. Patients were divided in three age groups: 0-4, 5-7 and 8-18 years. The use of ASIR combined to the adjustment of scan settings allowed a reduction in the median ED of 58 %, 82 % and 85 % in 0-4, 5-7 and 8-18 years group, respectively (7.3 ± 1.4 vs 3.1 ± 0.7 mSv, 5.5 ± 1.6 vs 1 ± 1.9 mSv and 5.3 ± 5.0 vs 0.8 ± 2.0 mSv, all p < 0,05). Prospective protocol was used in 51 % of children. The reduction in radiation dose was not associated with reduction in diagnostic image quality as assessed by the frequency of coronary segments with excellent or good image quality (88 %). cCT can be obtained at very low radiation doses in children using ASIR, and prospective acquisition with optimized imaging parameters. (orig.)

  16. Dose assessments for SFR 1

    International Nuclear Information System (INIS)

    Bergstroem, Ulla; Avila, Rodolfo; Ekstroem, Per-Anders; Cruz, Idalmis de la

    2008-05-01

    Following a review by the Swedish regulatory authorities of the safety analysis of the SFR 1 disposal facility for low and intermediate level waste, SKB has prepared an updated safety analysis, SAR-08. This report presents estimations of annual doses to the most exposed groups from potential radionuclide releases from the SFR 1 repository for a number of calculation cases, selected using a systematic approach for identifying relevant scenarios for the safety analysis. The dose estimates can be used for demonstrating that the long term safety of the repository is in compliance with the regulatory requirements. In particular, the mean values of the annual doses can be used to estimate the expected risks to the most exposed individuals, which can then be compared with the regulatory risk criteria for human health. The conversion from doses to risks is performed in the main report. For one scenario however, where the effects of an earthquake taking place close to the repository are analysed, risk calculations are presented in this report. In addition, prediction of concentrations of radionuclides in environmental media, such as water and soil, are compared with concentration limits suggested by the Erica-project as a base for estimating potential effects on the environment. The assessment of the impact on non-human biota showed that the potential impact is negligible. Committed collective dose for an integration period of 10,000 years for releases occurring during the first thousand years after closure are also calculated. The collective dose commitment was estimated to be 8 manSv. The dose calculations were carried out for a period of 100,000 years, which was sufficient to observe peak doses in all scenarios considered. Releases to the landscape and to a well were considered. The peaks of the mean annual doses from releases to the landscape are associated with C-14 releases to a future lake around year 5,000 AD. In the case of releases to a well, the peak annual doses

  17. Dose assessments for SFR 1

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Ulla (Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden)); Avila, Rodolfo; Ekstroem, Per-Anders; Cruz, Idalmis de la (Facilia AB, Bromma (Sweden))

    2008-06-15

    Following a review by the Swedish regulatory authorities of the safety analysis of the SFR 1 disposal facility for low and intermediate level waste, SKB has prepared an updated safety analysis, SAR-08. This report presents estimations of annual doses to the most exposed groups from potential radionuclide releases from the SFR 1 repository for a number of calculation cases, selected using a systematic approach for identifying relevant scenarios for the safety analysis. The dose estimates can be used for demonstrating that the long term safety of the repository is in compliance with the regulatory requirements. In particular, the mean values of the annual doses can be used to estimate the expected risks to the most exposed individuals, which can then be compared with the regulatory risk criteria for human health. The conversion from doses to risks is performed in the main report. For one scenario however, where the effects of an earthquake taking place close to the repository are analysed, risk calculations are presented in this report. In addition, prediction of concentrations of radionuclides in environmental media, such as water and soil, are compared with concentration limits suggested by the Erica-project as a base for estimating potential effects on the environment. The assessment of the impact on non-human biota showed that the potential impact is negligible. Committed collective dose for an integration period of 10,000 years for releases occurring during the first thousand years after closure are also calculated. The collective dose commitment was estimated to be 8 manSv. The dose calculations were carried out for a period of 100,000 years, which was sufficient to observe peak doses in all scenarios considered. Releases to the landscape and to a well were considered. The peaks of the mean annual doses from releases to the landscape are associated with C-14 releases to a future lake around year 5,000 AD. In the case of releases to a well, the peak annual doses

  18. Radiological environmental dose assessment methods and compliance dose results for 2015 operations at the Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Jannik, G. T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Dixon, K. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-09-01

    This report presents the environmental dose assessment methods and the estimated potential doses to the offsite public from 2015 Savannah River Site (SRS) atmospheric and liquid radioactive releases. Also documented are potential doses from special-case exposure scenarios - such as the consumption of deer meat, fish, and goat milk.

  19. Radiological environmental dose assessment methods and compliance dose results for 2015 operations at the Savannah River Site

    International Nuclear Information System (INIS)

    Jannik, G. T.; Dixon, K. L.

    2016-01-01

    This report presents the environmental dose assessment methods and the estimated potential doses to the offsite public from 2015 Savannah River Site (SRS) atmospheric and liquid radioactive releases. Also documented are potential doses from special-case exposure scenarios - such as the consumption of deer meat, fish, and goat milk.

  20. A model for radiological dose assessment in an urban environment

    International Nuclear Information System (INIS)

    Hwang, Won Tae; Kim, Eun Han; Jeong, Hyo Joon; Suh, Kyung Suk; Han, Moon Hee

    2007-01-01

    A model for radiological dose assessment in an urban environment, METRO-K has been developed. Characteristics of the model are as follows ; 1) mathematical structures are simple (i.e. simplified input parameters) and easy to understand due to get the results by analytical methods using experimental and empirical data, 2) complex urban environment can easily be made up using only 5 types of basic surfaces, 3) various remediation measures can be applied to different surfaces by evaluating the exposure doses contributing from each contamination surface. Exposure doses contributing from each contamination surface at a particular location of a receptor were evaluated using the data library of kerma values as a function of gamma energy and contamination surface. A kerma data library was prepared for 7 representative types of Korean urban building by extending those data given for 4 representative types of European urban buildings. Initial input data are daily radionuclide concentration in air and precipitation, and fraction of chemical type. Final outputs are absorbed dose rate in air contributing from the basic surfaces as a function of time following a radionuclide deposition, and exposure dose rate contributing from various surfaces constituting the urban environment at a particular location of a receptor. As the result of a contaminative scenario for an apartment built-up area, exposure dose rates show a distinct difference for surrounding environment as well as locations of a receptor

  1. Software development for estimating the conversion factor (k-factor) at suitable scan areas, relating the dose length product to the effective dose

    International Nuclear Information System (INIS)

    Kobayashi, Masanao; Asada, Yasuki; Suzuki, Syouichi; Kato, Ryouichi; Matsubara, Kosuke; Koshida, Kichiro; Matsunaga, Yuta; Kawaguchi, Ai; Haba, Tomonobu; Toyama, Hiroshi

    2017-01-01

    We developed a k-factor-creator software (kFC) that provides the k-factor for CT examination in an arbitrary scan area. It provides the k-factor from the effective dose and dose-length product by Imaging Performance Assessment of CT scanners and CT-EXPO. To assess the reliability, we compared the kFC-evaluated k-factors with those of the International Commission on Radiological Protection (ICRP) publication 102. To confirm the utility, the effective dose determined by coronary computed tomographic angiography (CCTA) was evaluated by a phantom study and k-factor studies. In the CCTA, the effective doses were 5.28 mSv in the phantom study, 2.57 mSv (51%) in the k-factor of ICRP, and 5.26 mSv (1%) in the k-factor of the kFC. Effective doses can be determined from the kFC-evaluated k-factors in suitable scan areas. Therefore, we speculate that the flexible k-factor is useful in clinical practice, because CT examinations are performed in various scan regions. (authors)

  2. Development of age-specific Japanese physical phantoms for dose evaluation in infant CT examinations

    International Nuclear Information System (INIS)

    Yamauchi-Kawaura, C.; Fujii, K.; Imai, K.; Ikeda, M.; Akahane, K.; Obara, S.; Yamauchi, M.; Narai, K.; Katsu, T.

    2016-01-01

    Secondary to the previous development of age-specific Japanese head phantoms, the authors designed Japanese torso phantoms for dose assessment in infant computed tomography (CT) examinations and completed a Japanese 3-y-old head-torso phantom. For design of age-specific torso phantoms (0, 0.5, 1 and 3 y old), anatomical structures were measured from CT images of Japanese infant patients. From the CT morphometry, it was found that rib cages of Japanese infants were smaller than those in Europeans and Americans. Radiophotoluminescence glass dosemeters were used for dose measurement of a 3-y-old head-torso phantom. To examine the validity of the developed phantom, organ and effective doses by the in-phantom dosimetry system were compared with simulation values in a web-based CT dose calculation system (WAZA-ARI). The differences in doses between the two systems were <20 % at the doses of organs within scan regions and effective doses in head, chest and abdomino-pelvic CT examinations. (authors)

  3. Development of a computational code for the internal doses assessment of the main radionuclides of occupational exposure at IPEN

    International Nuclear Information System (INIS)

    Claro, Thiago Ribeiro

    2011-01-01

    The dose resulting from internal contamination can be estimated with the use of biokinetic models combined with experimental results obtained from bioanalysis and assessment of the time of incorporation. The biokinetics models are represented by a set of compartments expressing the transportation, retention and elimination of radionuclides from the body. The ICRP publications, number 66, 78 and 100, present compartmental models for the respiratory tract, gastrointestinal tract and for systemic distribution for an array of radionuclides of interest for the radiological protection. The objective of this work is to develop a computational code for the internal doses assessment of the main radionuclides of occupational exposure at IPEN. Consequently serving as a agile and efficient tool for the designing, visualization and resolution of compartmental models of any nature. The architecture of the system was conceived containing two independent software: CBT - responsible for the setup and manipulation of models and SSID - responsible for the mathematical solution of the models. Four different techniques are offered for the resolution of system of equations, including semi-analytical and numerical methods, allowing for comparison of precision and performance of both. The software was developed in C≠ programming, using a Microsoft Access database and XML standards for file exchange with other applications. Compartmental models for uranium, thorium and iodine radionuclides were generated for the validation of the CBT software. The models were subsequently solved via SSID software and the results compared with the values published in the issue 78 of ICRP. In all cases the system replicated the values published by ICRP. (author)

  4. Peak Dose Assessment for Proposed DOE-PPPO Authorized Limits

    International Nuclear Information System (INIS)

    Maldonado, Delis

    2012-01-01

    The Oak Ridge Institute for Science and Education (ORISE), a U.S. Department of Energy (DOE) prime contractor, was contracted by the DOE Portsmouth/Paducah Project Office (DOE-PPPO) to conduct a peak dose assessment in support of the Authorized Limits Request for Solid Waste Disposal at Landfill C-746-U at the Paducah Gaseous Diffusion Plant (DOE-PPPO 2011a). The peak doses were calculated based on the DOE-PPPO Proposed Single Radionuclides Soil Guidelines and the DOE-PPPO Proposed Authorized Limits (AL) Volumetric Concentrations available in DOE-PPPO 2011a. This work is provided as an appendix to the Dose Modeling Evaluations and Technical Support Document for the Authorized Limits Request for the C-746-U Landfill at the Paducah Gaseous Diffusion Plant, Paducah, Kentucky (ORISE 2012). The receptors evaluated in ORISE 2012 were selected by the DOE-PPPO for the additional peak dose evaluations. These receptors included a Landfill Worker, Trespasser, Resident Farmer (onsite), Resident Gardener, Recreational User, Outdoor Worker and an Offsite Resident Farmer. The RESRAD (Version 6.5) and RESRAD-OFFSITE (Version 2.5) computer codes were used for the peak dose assessments. Deterministic peak dose assessments were performed for all the receptors and a probabilistic dose assessment was performed only for the Offsite Resident Farmer at the request of the DOE-PPPO. In a deterministic analysis, a single input value results in a single output value. In other words, a deterministic analysis uses single parameter values for every variable in the code. By contrast, a probabilistic approach assigns parameter ranges to certain variables, and the code randomly selects the values for each variable from the parameter range each time it calculates the dose (NRC 2006). The receptor scenarios, computer codes and parameter input files were previously used in ORISE 2012. A few modifications were made to the parameter input files as appropriate for this effort. Some of these changes

  5. The role of uncertainty analysis in dose reconstruction and risk assessment

    International Nuclear Information System (INIS)

    Hoffman, F.O.; Simon, S.L.; Thiessen. K.M.

    1996-01-01

    Dose reconstruction and risk assessment rely heavily on the use of mathematical models to extrapolate information beyond the realm of direct observation. Because models are merely approximations of real systems, their predictions are inherently uncertain. As a result, full disclosure of uncertainty in dose and risk estimates is essential to achieve scientific credibility and to build public trust. The need for formal analysis of uncertainty in model predictions was presented during the nineteenth annual meeting of the NCRP. At that time, quantitative uncertainty analysis was considered a relatively new and difficult subject practiced by only a few investigators. Today, uncertainty analysis has become synonymous with the assessment process itself. When an uncertainty analysis is used iteratively within the assessment process, it can guide experimental research to refine dose and risk estimates, deferring potentially high cost or high consequence decisions until uncertainty is either acceptable or irreducible. Uncertainty analysis is now mandated for all ongoing dose reconstruction projects within the United States, a fact that distinguishes dose reconstruction from other types of exposure and risk assessments. 64 refs., 6 figs., 1 tab

  6. Application of the ELDO approach to assess cumulative eye lens doses for interventional cardiologists

    International Nuclear Information System (INIS)

    Farah, J.; Jacob, S.; Clairand, I.; Struelens, L.; Vanhavere, F.; Auvinen, A.; Koukorava, C.; Schnelzer, M.

    2015-01-01

    In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiation. The present paper applies one of the ELDO approaches, correlating eye lens dose to whole-body doses, to assess cumulative eye lens dose for 14 different Finnish interventional cardiologists for whom annual whole-body dose records were available for their entire working period. The estimated cumulative left and right eye lens dose ranged from 8 to 264 mSv and 6 to 225 mSv, respectively. In addition, calculations showed annual eye lens doses sometimes exceeding the new ICRP annual limit of 20 mSv. The work also highlights the large uncertainties associated with the application of such an approach proving the need for dedicated dosimetry systems in the routine monitoring of the eye lens dose. (authors)

  7. Radiation dose assessment in nuclear medicine

    International Nuclear Information System (INIS)

    Stabin, M.G.

    2002-01-01

    In any application involving the use of ionizing radiation in humans, risks and benefits must be properly evaluated and balanced. Radionuclides are used in nuclear medicine in a variety of diagnostic and therapeutic procedures. Recently, interest has grown in therapeutic agents for a number of applications in nuclear medicine, particularly in the treatment of hematologic and non-hematologic malignancies. This has heightened interest in the need for radiation dose calculations and challenged the scientific community to develop more patient-specific and relevant dose models. Consideration of radiation dose in such studies is central to efforts to maximize dose to tumor while sparing normal tissues. In many applications, a significant absorbed dose may be received by some radiosensitive organs, particularly the active marrow. This talk will review the methods and models used in internal dosimetry in nuclear medicine, and discuss some current trends and challenges in this field

  8. Updated radiological dose assessment of Bikini and Eneu Islands at Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Mount, M.E.; Phillips, W.A.; Stuart, M.L.; Thompson, S.E.; Conrado, C.L.; Stoker, A.C.

    1982-01-01

    This report is part of a continuing effort to refine dose assessments for resettlement options at Bikini Atoll. Radionuclide concentration data developed at Bikini Atoll since 1977 have been used in conjunction with recent dietary information and current dose models to develop the annual dose rate and 30- and 50-y integral doses presented here for Bikini and Eneu Island living patterns. The terrestrial food chain is the most significant exposure pathway--it contributes more than 50% of the total dose--and external gamma exposure is the second most significant pathway. Other pathways evaluated are the marine food chain, drinking water, and inhalation. Cesium-137 produces more than 85% of the predicted dose; 90 Sr is the second most significant radionuclide; 60 Co contributes to the external gamma exposure in varying degrees, but is a small part of the total predicted dose; the transuranic radionuclides contribute a small portion of the total predicted lung and bone doses but do present a long-term source of exposure. Maximum annual dose rates for Bikini Island are about 1 rem/y for the whole body and bone marrow when imported foods are available and about 1.9 rem/y when imports are unavailable. Maximum annual dose rates for Eneu Island when imports are available are 130 mrem/y for the whole body and 136 mrem/y for bone marrow. Similar doses when imported foods are unavailable are 245 and 263 mrem/y, respectively. The 30-y integral doses for Bikini Island are about 23 rem for whole body and bone marrow when imported foods are available and more than 40 rem when imports are unavailable. The Eneu Island 30-y integral doses for whole body and bone marrow are about 3 rem when imports are available and 5.5 and 6.1 rem, respectively, when imports are unavailable. Doses from living patterns involving some combination of Bikini and Eneu Islands fall between the doses listed above for each island separately

  9. A phantom for assessing the personal dose equivalent, HP(10)

    International Nuclear Information System (INIS)

    Santoro, C.; Filho, J.A

    2013-01-01

    Characteristics of a phantom designed to evaluate the personal dose equivalent, H P (10), and appropriate for photographic dosimetry are presented. It is called HP(10) phantom due to cavities constructed to insert dosimetric films at a depth of 10 mm. The H P (10) phantom is irradiated with ionizing radiation energy, E, from 45 to 1250 keV, with doses ranging from 0.2 to 50 mSv. It is positioned in the direction α = 0 °, and the radiation field focusing perpendicular to its front surface. So, are established calibration curves of dosimeters in the position conventionally true and quantities H P (10). It made a comparison between the responses obtained with the H P (10) phantom and responses obtained when using the calibration procedure recommended by ISO dosimeters. The ISO recommends getting the air kerma, Ka, for photons at test point of the radiation field by an ionization chamber. And through conversion coefficients, h pK (10; E, α), becomes the air kerma for H P (10). The ISO 4037-3 recommendation has been studied by researchers to ensure that the low energy spectral differences occur in radiation fields which are generated by various X-ray equipment, and induce changes in the percentages of conversion coefficients on the order of 10% to 90% . On the basis of the recommendations ISO, this article develops phantom able to assess the dose to the influence of scattering and absorption of radiation, its implications with respect to dosimetry, providing improvement in the assessment of doses. (author)

  10. Assessment of dose conversion factors in a generic biosphere of a Korea HLW repository

    International Nuclear Information System (INIS)

    Hwang, Y. S.; Park, J. B.; Kang, C. H.

    2002-01-01

    Radioactive species released from a waste repository migrate through engineered and natural barriers and eventually reach the biosphere. Once entered the biosphere, contaminants transport various exposure pathways and finally reach a human. In this study the full RES matrix explaining the key compartments in the biosphere and their interactions is introduced considering the characteristics of the Korean biosphere. Then the three exposure groups are identified based on the compartments of interest. The full exposure pathways and corresponding mathematical expression for mass transfer coefficients and etc are developed and applied to assess the dose conversion factors of nuclides for a specific exposure group. Dose conversion factors assessed in this study will be used for total system performance assessment of a potential Korean HLW repository

  11. Accident consequence assessment and siting criteria development

    International Nuclear Information System (INIS)

    Kollas, J.G.

    1988-01-01

    The methodology developed is based on assessing the average over a large spectrum of meteorological conditions whole body collective dose resulting from a severe reference accident. The assessment of this dose is performed by code CRAC.GAEC, the Greek A.E.C. version of code CRAC2. The collective dose, which is chosen as a measure of the social radiation risk, is compared to the dose corresponding to a level of social risk encountered historically in energy production as a whole. The outcome of the comparison can be the determination of one or more sectors of acceptable sites for a set of specific conditions considered, such as the reactor characteristics. The present approach was aimed to deal with the problems stemming from the demographic idiomorphy of Greece, where one third of the country's population is concentrated in Athens, with the rest of the country exhibiting small population densities. One of the applications of the methodology developed concerned the identification of acceptable sites near Athens. For these sites the risk from the reference severe accident of a standard reactor to the over three millions inhabitants of Athens is less tan the risk corresponding to the same population that is due to energy production

  12. An airborne dispersion/dose assessment computer program. Phase 1

    International Nuclear Information System (INIS)

    Scott, C.K.; Kennedy, E.R.; Hughs, R.

    1991-05-01

    The Atomic Energy Control Board (AECB) staff have a need for an airborne dispersion-dose assessment computer programme for a microcomputer. The programme must be capable of analyzing the dispersion of both radioactive and non-radioactive materials. A further requirement of the programme is that it be implemented on the AECB complex of microcomputers and that it have an advanced graphical user interface. A survey of computer programs was conducted to determine which, if any, could meet the AECB's requirements in whole or in part. Ten programmes were selected for detailed review including programs for nuclear and non-radiological emergencies. None of the available programmes for radiation dose assessment meets all the requirements for reasons of user interaction, method of source term estimation or site specificity. It is concluded that the best option for meeting the AECB requirements is to adopt the CAMEO programme (specifically the ALOHA portion) which has a superior graphical user interface and add the necessary models for radiation dose assessment

  13. Revue of some dosimetry and dose assessment European projects

    International Nuclear Information System (INIS)

    Bolognese-Milsztajn, T.; Frank, D.; Lacoste, V.; Pihet, P.

    2006-01-01

    Full text of publication follows: Within the 5. Framework Programme of the European Commission several project dealing with dosimetry and dose assessment for internal and external exposure have been supported. A revue of the results of some of them is presented in this paper. The EURADOS network which involved 50 dosimetry institutes in EUROPE has coordinated the project DOSIMETRY NETWORK: the main results achieved within this action are the following: - The release on the World Wide Web of the EURADOS Database of Dosimetry Research Facilities; - The realisation of the report 'Harmonization of Individual Monitoring (IM) in Europe'; - The continuation of the intercomparisons programme of environmental radiation monitoring systems; - The realisation of the report Cosmic radiation exposure of aircraft crew. The EVIDOS project aimed at evaluating state of the art dosimetry techniques in representative workplaces of the nuclear industry with complex mixed neutron-photon radiation fields. This paper summarises the main findings from a practical point of view. Conclusions and recommendations will be given concerning characterisation of radiation fields, methods to derive radiation protection quantities and dosimeters results. The IDEA project aimed to improve the assessment of incorporated radionuclides through developments of advanced in-vivo and bioassay monitoring techniques and making use of such enhancements for improvements in routine monitoring. The primary goal was to categorize those new developments regarding their potential and eligibility for the routine monitoring community. The costs of monitoring for internal exposures in the workplace are usually significantly greater than the equivalent costs for external exposures. There is therefore a need to ensure that resources are employed with maximum effectiveness. The EC-funded OMINEX (Optimisation of Monitoring for Internal Exposure) project has developed methods for optimising the design and implementation of

  14. Preclinical assessment of HIV vaccines and microbicides by repeated low-dose virus challenges.

    Directory of Open Access Journals (Sweden)

    Roland R Regoes

    2005-08-01

    Full Text Available Trials in macaque models play an essential role in the evaluation of biomedical interventions that aim to prevent HIV infection, such as vaccines, microbicides, and systemic chemoprophylaxis. These trials are usually conducted with very high virus challenge doses that result in infection with certainty. However, these high challenge doses do not realistically reflect the low probability of HIV transmission in humans, and thus may rule out preventive interventions that could protect against "real life" exposures. The belief that experiments involving realistically low challenge doses require large numbers of animals has so far prevented the development of alternatives to using high challenge doses.Using statistical power analysis, we investigate how many animals would be needed to conduct preclinical trials using low virus challenge doses. We show that experimental designs in which animals are repeatedly challenged with low doses do not require unfeasibly large numbers of animals to assess vaccine or microbicide success.Preclinical trials using repeated low-dose challenges represent a promising alternative approach to identify potential preventive interventions.

  15. Microdosimetric approach for lung dose assessments

    International Nuclear Information System (INIS)

    Hofmann, W.; Steinhausler, F.; Pohl, E.; Bernroider, G.

    1980-01-01

    In the macroscopic region the term ''organ dose'' is related to an uniform energy deposition within a homogeneous biological target. Considering the lung, inhaled radioactive nuclides, however, show a significant non-uniform distribution pattern throughout the respiratory tract. For the calculation of deposition and clearance of inhaled alpha-emitting radionuclides within different regions of this organ, a detailed compartment model, based on the Weibel model A was developed. Since biological effects (e.g. lung cancer initiation) are primarily caused at the cellular level, the interaction of alpha particles with different types of cells of the lung tissue was studied. The basic approach is to superimpose alpha particle tracks on magnified images of randomly selected tissue slices, simulating alpha emitting sources. Particle tracks are generated by means of a specially developed computer program and used as input data for an on-line electronic image analyzer (Quantimet-720). Using adaptive pattern recognition methods the different cells in the lung tissue can be identified and their distribution within the whole organ determined. This microdosimetric method is applied to soluble radon decay products as well as to insoluble, highly localized, plutonium particles. For a defined microdistribution of alpha emitters, the resulting dose, integrated over all cellular dose values, is compared to the compartmental doses of the ICRP lung model. Furthermore this methodology is also applicable to other organs and tissues of the human body for dose calculations in practical health physics. (author)

  16. AGING FACILITY WORKER DOSE ASSESSMENT

    International Nuclear Information System (INIS)

    R.L. Thacker

    2005-01-01

    The purpose of this calculation is to estimate radiation doses received by personnel working in the Aging Facility performing operations to transfer aging casks to the aging pads for thermal and logistical management, stage empty aging casks, and retrieve aging casks from the aging pads for further processing in other site facilities. Doses received by workers due to aging cask surveillance and maintenance operations are also included. The specific scope of work contained in this calculation covers both collective doses and individual worker group doses on an annual basis, and includes the contributions due to external and internal radiation from normal operation. There are no Category 1 event sequences associated with the Aging Facility (BSC 2004 [DIRS 167268], Section 7.2.1). The results of this calculation will be used to support the design of the Aging Facility and to provide occupational dose estimates for the License Application. The calculations contained in this document were developed by Environmental and Nuclear Engineering of the Design and Engineering Organization and are intended solely for the use of the Design and Engineering Organization in its work regarding facility operation. Yucca Mountain Project personnel from the Environmental and Nuclear Engineering should be consulted before use of the calculations for purposes other than those stated herein or use by individuals other than authorized personnel in Environmental and Nuclear Engineering

  17. Establishment of exposure dose assessment laboratory in National Radiation Emergency Medical Center (NREMC)

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jae Ryong; Ha, Wi Ho; Yoon, Seok Won; Han, Eun Ae; Lee, Seung Sook [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2011-10-15

    As unclear industry grown, 432 of the nuclear power plants are operating and 52 of NPPs are under construction currently. Increasing use of radiation or radioisotopes in the field of industry, medical purpose and research such as non-destructive examination, computed tomography and x-ray, etc. constantly. With use of nuclear or radiation has incidence possibility for example the Fukushima NPP incident, the Goiania accident and the Chernobyl Nuclear accident. Also the risk of terror by radioactive material such as Radiological Dispersal Device(RDD) etc. In Korea, since the 'Law on protection of nuclear facilities and countermeasure for radioactive preparedness was enacted in 2003, the Korean institute of Radiological and Medical Sciences(KIRAMS) was established for the radiation emergency medical response in radiological disaster due to nuclear accident, radioactive terror and so on. Especially National Radiation Emergency Medical Center(NREMC) has the duty that is protect citizens from nuclear, radiological accidents or radiological terrors through the emergency medical preparedness. The NREMC was established by the 39-article law on physical protection of nuclear material and facilities and measures for radiological emergencies. Dose assessment or contamination survey should be performed which provide the radiological information for medical response. For this reason, the NREMC establish and re-organized dose assessment system based on the existing dose assessment system of the NREMC recently. The exposure dose could be measured by physical and biological method. With these two methods, we can have conservative dose assessment result. Therefore the NREMC established the exposure dose assessment laboratory which was re-organized laboratory space and introduced specialized equipment for dose assessment. This paper will report the establishment and operation of exposure dose assessment laboratory for radiological emergency response and discuss how to enhance

  18. Researches and Applications of ESR Dosimetry for Radiation Accident Dose Assessment

    International Nuclear Information System (INIS)

    Wu, K.; Guo, L.; Cong, J.B.; Sun, C.P.; Hu, J.M.; Zhou, Z.S.; Wang, S.; Zhang, Y.; Zhang, X.; Shi, Y.M.

    1998-01-01

    The aim of this work was to establish methods suitable for practical dose assessment of people involved in ionising radiation accidents. Some biological materials of the human body and materials possibly carried or worn by people were taken as detection samples. By using electron spin resonance (ESR) techniques, the basic dosimetric properties of selected materials were investigated in the range above the threshold dose of human acute haemopoietic radiation syndrome. The dosimetric properties involved included dose response properties of ESR signals, signal stabilities, distribution of background signals, the lowest detectable dose value, radiation conditions, environmental effects on the detecting process, etc. Several practical dose analytical indexes and detecting methods were set up. Some of them (bone, watch glass and tooth enamel) had also been successfully used in the dose assessment of people involved in three radiation accidents, including the Chernobyl reactor accident. This work further proves the important role of ESR techniques in radiation accident dose estimation. (author)

  19. Dose related risk and effect assessment model (DREAM) -- A more realistic approach to risk assessment of offshore discharges

    International Nuclear Information System (INIS)

    Johnsen, S.; Furuholt, E.

    1995-01-01

    Risk assessment of discharges from offshore oil and gas production to the marine environment features determination of potential environmental concentration (PEC) levels and no observed effect concentration (NOEC) levels. The PEC values are normally based on dilution of chemical components in the actual discharge source in the recipient, while the NOEC values are determined by applying a safety factor to acute toxic effects from laboratory tests. The DREAM concept focuses on realistic exposure doses as function of contact time and dilution, rather than fixed exposure concentrations of chemicals in long time exposure regimes. In its present state, the DREAM model is based on a number of assumptions with respect to the link between real life exposure doses and effects observed in laboratory tests. A research project has recently been initiated to develop the concept further, with special focus on chronic effects of different chemical compounds on the marine ecosystem. One of the questions that will be addressed is the link between exposure time, dose, concentration and effect. Validation of the safety factors applied for transforming acute toxic data into NOEC values will also be included. The DREAM model has been used by Statoil for risk assessment of discharges from new and existing offshore oil and gas production fields, and has been found to give a much more realistic results than conventional risk assessment tools. The presentation outlines the background for the DREAM approach, describes the model in its present state, discusses further developments and applications, and shows a number of examples on the performance of DREAM

  20. EMP Attachment 3 DOE-SC PNNL Site Dose Assessment Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, Sandra F.

    2011-12-21

    This Dose Assessment Guidance (DAG) describes methods to use to determine the Maximally-Exposed Individual (MEI) location and to estimate dose impact to that individual under the U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest National Laboratory (PNNL) Site Environmental Monitoring Plan (EMP). This guidance applies to public dose from radioactive material releases to the air from PNNL Site operations. This document is an attachment to the Pacific Northwest National Laboratory (PNNL) Environmental Monitoring Plan (EMP) and describes dose assessment guidance for radiological air emissions. The impact of radiological air emissions from the U.S. Department of Energy Office of Science (DOE-SC) PNNL Site is indicated by dose estimates to a maximally exposed member of the public, referred to as the maximally exposed individual (MEI). Reporting requirements associated with dose to members of the public from radiological air emissions are in 40 CFR Part 61.94, WAC 246-247-080, and DOE Order 458.1. The DOE Order and state standards for dose from radioactive air emissions are consistent with U.S. Environmental Protection Agency (EPA) dose standards in 40 CFR 61.92 (i.e., 10 mrem/yr to a MEI). Despite the fact that the current Contract Requirements Document (CRD) for the DOE-SC PNNL Site operations does not include the requirement to meet DOE CRD 458.1, paragraph 2.b, public dose limits, the DOE dose limits would be met when EPA limits are met.

  1. Local dose assessment for a contaminated wound

    International Nuclear Information System (INIS)

    Piechowski, J.; Chaptinel, Y.

    2004-01-01

    Contaminated wounds present a great variability concerning the type of lesion. Assessment of the local dose is one amongst other factors for a decision as to the surgical operation. A simple model has been used to calculate the doses in a representative volume, that of a phalanx for instance. The dose rates are given for current radionuclides. The method of calculation is enough simple in order to allow the practitioners to use it in situations involving other radionuclides. Committed dose depends on the biological half-life which can be estimated from the local measurements. Some examples of calculation of committed dose are given considering half-lives characteristic of the compound. Transposition of the dose to the local risk is easy for the non-stochastic risk. Conversely, this is not the case for the risk of chronic inflammation or cancer. The latter question could only be solved by a feedback based on the analysis of real till now observed cases, nevertheless taking into account the fact that the available data are generally not so easy to make use for establishing an unquestionable dose - effect relation. A critical issue remains open as to the use of these doses for their comparison to the regulatory limits and for the subsequent decisions in case of exceeding the limits. The actual impact of an irradiation, especially by alpha particles, is not linked to the calculated dose in a simple and direct way. This question needs further consideration and perhaps a practical guide concerning this topic would be useful. The anatomical (surgical side effects), psychological and professional consequences should have a large weight relatively to the doses, obviously except for the cases, involving actually large contamination. (authors)

  2. Software Development for Estimating the Conversion Factor (K-Factor) at Suitable Scan Areas, Relating the Dose Length Product to the Effective Dose.

    Science.gov (United States)

    Kobayashi, Masanao; Asada, Yasuki; Matsubara, Kosuke; Suzuki, Syouichi; Koshida, Kichiro; Matsunaga, Yuta; Kawaguchi, Ai; Haba, Tomonobu; Toyama, Hiroshi; Kato, Ryouichi

    2017-05-01

    We developed a k-factor-creator software (kFC) that provides the k-factor for CT examination in an arbitrary scan area. It provides the k-factor from the effective dose and dose-length product by Imaging Performance Assessment of CT scanners and CT-EXPO. To assess the reliability, we compared the kFC-evaluated k-factors with those of the International Commission on Radiological Protection (ICRP) publication 102. To confirm the utility, the effective dose determined by coronary computed tomographic angiography (CCTA) was evaluated by a phantom study and k-factor studies. In the CCTA, the effective doses were 5.28 mSv in the phantom study, 2.57 mSv (51%) in the k-factor of ICRP, and 5.26 mSv (1%) in the k-factor of the kFC. Effective doses can be determined from the kFC-evaluated k-factors in suitable scan areas. Therefore, we speculate that the flexible k-factor is useful in clinical practice, because CT examinations are performed in various scan regions. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Biological dosimetry: chromosomal aberration analysis for dose assessment

    International Nuclear Information System (INIS)

    1986-01-01

    In view of the growing importance of chromosomal aberration analysis as a biological dosimeter, the present report provides a concise summary of the scientific background of the subject and a comprehensive source of information at the technical level. After a review of the basic principles of radiation dosimetry and radiation biology basic information on the biology of lymphocytes, the structure of chromosomes and the classification of chromosomal aberrations are presented. This is followed by a presentation of techniques for collecting blood, storing, transporting, culturing, making chromosomal preparations and scaring of aberrations. The physical and statistical parameters involved in dose assessment are discussed and examples of actual dose assessments taken from the scientific literature are given

  4. Biological dose assessment of 15 victims in Haerbin radiation accident

    International Nuclear Information System (INIS)

    Liu, Jian-xiang; Huang, Min-yan; Ruan, Jian-lei; Bai, Yu-shu; Xu, Su

    2008-01-01

    Full text: a) On July 5 and 8, 2005, Two patients with bone marrow suppression were successively hospitalized by the First Affiliated Hospital of Haerbin Medical University. Examination results showed that the patients seemed to get suspicious radiation disease. On July 13, 2005, a radioactive source was found in the patients' dwelling. The radiation source is Iridium-192 with 0.5 Ci(1.85 x 10 10 Bq) radioactivity. The radiation source is a metal bar which is a kind of radioactive industrial detection source for welding. The source is currently stored in the urban radioactive waste storehouse of Heilongjiang province. After finding the radioactive source on July 13, The Haerbin municipal government initiated an emergency response plan and developed medical rescue, radioactive source examination and case detection through organizing ministries involving health, environmental protection and public security. After receiving a report at 17:00 on July 14, 2005, Chinese Ministry of Health immediately sent experts to the spot for investigation, dose estimation and direction of patients' rescue. Health authority carried out physical examination twice on 113 residents within 30 meters to the source, among which 4 got radiation sickness, 5 showed abnormal hemotogram, and others showed no abnormal response. Of 4 patients with radiation sickness, one 81 year old patient has died of severe bone marrow form of sub acute radiation sickness coupled with lung infection and prostrate apparatus at 13:00 on Oct., 20. Two children have been treated in Beitaiping Road Hospital in Beijing, another patient has been treated in local hospital. b) Biological dosimetry using conventional chromosome aberration analysis in human peripheral blood lymphocytes has been shown as a reliable and useful tool in medical management of radiation accident victims. Peripheral blood lymphocytes of the victims were cultured using conventional culture medium with colchicine added at the beginning. Chromosome

  5. ARAC: A flexible real-time dose consequence assessment system

    International Nuclear Information System (INIS)

    Ellis, J.S.; Sullivan, T.J.

    1993-01-01

    Since its beginning, the Atmospheric Release Advisory Capability (ARAC), an emergency radiological dose assessment service of the US Government, has been called on to do consequence assessments for releases into the atmosphere of radionuclides and a variety of other substances. Some of the more noteworthy emergency responses have been for the Three Mile Island and Chernobyl nuclear power reactor accidents, and more recently, for a cloud of gases from a rail-car spill into the Sacramento river of the herbicide metam sodium, smoke from hundreds of burning oil wells in Kuwait, and ash clouds from the eruption of Mt. Pinatubo. The spatial scales of these responses range from local, to regional, to global, and the response periods from hours, to weeks, to months. Because of the variety of requirements of each unique assessment, ARAC has developed and maintains a flexible system of people, computer software and hardware

  6. Assessment of organ equivalent doses and effective doses from diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Park, Sang Hyun

    2003-02-01

    The MIRD-type adult male, female and age 10 phantoms were constructed to evaluate organ equivalent dose and effective dose of patient due to typical diagnostic X-ray examination. These phantoms were constructed with external and internal dimensions of Korean. The X-ray energy spectra were generated with SPEC78. MCNP4B ,the general-purposed Monte Carlo code, was used. Information of chest PA , chest LAT, and abdomen AP diagnostic X-ray procedures was collected on the protocol of domestic hospitals. The results showed that patients pick up approximate 0.02 to 0.18 mSv of effective dose from a single chest PA examination, and 0.01 to 0.19 mSv from a chest LAT examination depending on the ages. From an abdomen AP examination, patients pick up 0.17 to 1.40 mSv of effective dose. Exposure time, organ depth from the entrance surface and X-ray beam field coverage considerably affect the resulting doses. Deviation among medical institutions is somewhat high, and this indicated that medical institutions should interchange their information and the need of education for medical staff. The methodology and the established system can be applied, with some expansion, to dose assessment for other medical procedures accompanying radiation exposure of patients like nuclear medicine or therapeutic radiology

  7. 4D cone beam CT-based dose assessment for SBRT lung cancer treatment

    International Nuclear Information System (INIS)

    Cai, Weixing; Dhou, Salam; Cifter, Fulya; Myronakis, Marios; Hurwitz, Martina H; Williams, Christopher L; Berbeco, Ross I; Seco, Joao; Lewis, John H

    2016-01-01

    The purpose of this research is to develop a 4DCBCT-based dose assessment method for calculating actual delivered dose for patients with significant respiratory motion or anatomical changes during the course of SBRT. To address the limitation of 4DCT-based dose assessment, we propose to calculate the delivered dose using time-varying (‘fluoroscopic’) 3D patient images generated from a 4DCBCT-based motion model. The method includes four steps: (1) before each treatment, 4DCBCT data is acquired with the patient in treatment position, based on which a patient-specific motion model is created using a principal components analysis algorithm. (2) During treatment, 2D time-varying kV projection images are continuously acquired, from which time-varying ‘fluoroscopic’ 3D images of the patient are reconstructed using the motion model. (3) Lateral truncation artifacts are corrected using planning 4DCT images. (4) The 3D dose distribution is computed for each timepoint in the set of 3D fluoroscopic images, from which the total effective 3D delivered dose is calculated by accumulating deformed dose distributions. This approach is validated using six modified XCAT phantoms with lung tumors and different respiratory motions derived from patient data. The estimated doses are compared to that calculated using ground-truth XCAT phantoms. For each XCAT phantom, the calculated delivered tumor dose values generally follow the same trend as that of the ground truth and at most timepoints the difference is less than 5%. For the overall delivered dose, the normalized error of calculated 3D dose distribution is generally less than 3% and the tumor D95 error is less than 1.5%. XCAT phantom studies indicate the potential of the proposed method to accurately estimate 3D tumor dose distributions for SBRT lung treatment based on 4DCBCT imaging and motion modeling. Further research is necessary to investigate its performance for clinical patient data. (paper)

  8. Review of Cl-36 behaviour in the biosphere and implications for long-term dose assessment

    International Nuclear Information System (INIS)

    Leclerc, E.; Smith, G.; Lloyd, P.

    2009-01-01

    Cl-36 is an important contributor to potential radiation doses in the long term, arising from release into the biosphere from radioactive waste disposal facilities. Its special attributes include its long half-life, high mobility in many environmental conditions, and potentially high uptake into plants and hence accumulation in the food-chain. Review has shown very wide ranges of Cl-36 values of parameters commonly employed in models used for long term doses. Accordingly, a workshop was held recently within the aegis of the international collaboration project BIOPROTA, to consider the causes of such variation, and in particular: to provide an open forum for presentation and discussion of environmental processes involved in Cl-36 migration and accumulation, and on how to model them, and to develop recommendations for the direction of continuing research as input to long-term radiological assessment. Participation in the workshop included specialists and contributions from North America, Europe and Japan in environmental behaviour of chlorine, radioecology of Cl-36 and long term dose assessment. This paper will present the output from that workshop in the context of the wider aspects of performance assessment, taking into account information about: waste types for which Cl-36 is a significant component of the total Cl-36 inventory; data requirements for the dose assessment models, notably concerning uptake from soils into food crops which may lead to higher doses than direct consumption of contaminated drinking water; critical data weaknesses which may lead to overly pessimistic dose estimates; time dependent factors within a single growing season which can affect final concentrations in food crops for animals and humans; alternative conceptual models for the behaviour of Cl-36 in the environment, notably models structured as other trace radionuclide dose assessment models as opposed to models which are based specifically on chlorine behaviour which should take

  9. Human data and internal dose assessment

    International Nuclear Information System (INIS)

    Kawamura, H.; Tanaka, G.; Shiraishi, K.; Yamamoto, M.

    1992-01-01

    Recent data on physical and anatomical and physiological or metabolic data regarding Japanese Reference Man is briefly reviewed. This includes reference values for masses of all organs and tissues proposed for a Japanese Reference male adult. Part of the data is used to assess alpha doses to bone tissues from naturally occurring 226 Ra in bone of Japanese adult. (author)

  10. Eye lens exposure to medical staff performing electrophysiology procedures: dose assessment and correlation to patient dose

    International Nuclear Information System (INIS)

    Ciraj-Bjelac, Olivera; Bozovic, Predrag; Arandjic, Danijela; Antic, Vojislav; Selakovic, Jovana; Pavlovic, Sinisa

    2016-01-01

    The purpose of this study was to assess the patient exposure and staff eye dose levels during implantation procedures for all types of pacemaker therapy devices performed under fluoroscopic guidance and to investigate potential correlation between patients and staff dose levels. The mean eye dose during pacemaker/defibrillator implementation was 12 μSv for the first operator, 8.7 μSv for the second operator/nurse and 0.50 μSv for radiographer. Corresponding values for cardiac re-synchronisation therapy procedures were 30, 26 and 2.0 μSv, respectively. Significant (p < 0.01) correlation between the eye dose and the kerma-area product was found for the first operator and radiographers, but not for other staff categories. The study revealed eye dose per procedure and eye dose normalised to patient dose indices for different staff categories and provided an input for radiation protection in electrophysiology procedures. (authors)

  11. The Thule accident: Assessment of radiation doses from terrestrial radioactive contamination

    International Nuclear Information System (INIS)

    Ulbak, K.

    2011-12-01

    Risoe DTU has carried out research on the terrestrial contamination in the Thule area after the radioactive contents of four nuclear weapons were dispersed following the crash of an American B-52 bomber in 1968. The results of Risoe DTU's studies are described in the report Thule-2007 - Investigation of radioactive pollution on land, which covers all measurements that were carried out on land in Thule in the years 2003, 2006, 2007 and 2008. The present report uses Risoe DTU's report as a basis for assessing radiation doses and consequently the risk for individuals as a result of terrestrial radioactive contamination in the Thule area. The assessment of radiation doses involves a number of conservative assumptions, estimates, and measurements, all of which are subject to considerable uncertainty. In some cases, models have been used based on experiences from other contaminated areas elsewhere in the world, which are subject to climatic and other conditions that diverge from those in the Thule area. The calculated doses are thus associated with considerable uncertainty, which must be taken into account when the results are used for comparison and when the risks of staying in the Thule area are assessed. It has therefore been chosen to provide the assessed radiation doses in the form of indicative orders of magnitude, which are applicable to everyone who might stay in the area, across various age groups. If the estimated doses in this report are combined with the National Institute of Radiation Protections recommended reference level for contamination as a result of the Thule Accident of 1 mSv/year, the assessed magnitudes of radiation doses for inhalation and ingestion as exposure pathways are many orders of magnitude below the reference level (10,00010 million times smaller). The wound contamination exposure pathway has a magnitude of radiation dose that is smaller than the reference level by a factor of 101000, and it should be recalled that the probability of this

  12. The Thule accident: Assessment of radiation doses from terrestrial radioactive contamination

    Energy Technology Data Exchange (ETDEWEB)

    Ulbak, K. (National Institute of Radiation Protection, Herlev (Denmark))

    2011-12-15

    Risoe DTU has carried out research on the terrestrial contamination in the Thule area after the radioactive contents of four nuclear weapons were dispersed following the crash of an American B-52 bomber in 1968. The results of Risoe DTU's studies are described in the report Thule-2007 - Investigation of radioactive pollution on land, which covers all measurements that were carried out on land in Thule in the years 2003, 2006, 2007 and 2008. The present report uses Risoe DTU's report as a basis for assessing radiation doses and consequently the risk for individuals as a result of terrestrial radioactive contamination in the Thule area. The assessment of radiation doses involves a number of conservative assumptions, estimates, and measurements, all of which are subject to considerable uncertainty. In some cases, models have been used based on experiences from other contaminated areas elsewhere in the world, which are subject to climatic and other conditions that diverge from those in the Thule area. The calculated doses are thus associated with considerable uncertainty, which must be taken into account when the results are used for comparison and when the risks of staying in the Thule area are assessed. It has therefore been chosen to provide the assessed radiation doses in the form of indicative orders of magnitude, which are applicable to everyone who might stay in the area, across various age groups. If the estimated doses in this report are combined with the National Institute of Radiation Protection's recommended reference level for contamination as a result of the Thule Accident of 1 mSv/year, the assessed magnitudes of radiation doses for inhalation and ingestion as exposure pathways are many orders of magnitude below the reference level (10,000-10 million times smaller). The wound contamination exposure pathway has a magnitude of radiation dose that is smaller than the reference level by a factor of 10-1000, and it should be recalled that the

  13. Dose assessment activities in the Republic of the Marshall Islands.

    Science.gov (United States)

    Simon, S L; Graham, J C

    1996-10-01

    Dose assessments, both retrospective and prospective, comprise one important function of a radiological study commissioned by the Republic of the Marshall Islands (RMI) government in late 1989. Estimating past or future exposure requires the synthesis of information from historical data, results from a recently completed field monitoring program, laboratory measurements, and some experimental studies. Most of the activities in the RMI to date have emphasized a pragmatic rather than theoretical approach. In particular, most of the recent effort has been expended on conducting an independent radiological monitoring program to determine the degree of deposition and the geographical extent of weapons test fallout over the nation. Contamination levels on 70% of the land mass of the Marshall Islands were unknown prior to 1994. The environmental radioactivity data play an integral role in both retrospective and prospective assessments. One recent use of dose assessment has been to interpret environmental measurements of radioactivity into annual doses that might be expected at every atoll. A second use for dose assessment has been to determine compliance with a dose action level for the rehabilitation of Rongelap Island. Careful examination of exposure pathways relevant to the island lifestyle has been necessary to accommodate these purposes. Examples of specific issues studied include defining traditional island diets as well as current day variations, sources of drinking water, uses of tropical plants including those consumed for food and for medicinal purposes, the nature and microvariability of plutonium particles in the soil and unusual pathways of exposure, e.g., that which might be associated with cooking and washing outdoors and inadvertent soil ingestion. A study on the prevalence of thyroid disease is also being conducted and the geographic pattern of disease may be useful as a bioindicator of the geographic pattern of exposure to radioiodine. Finally, an

  14. Thoron in the air: assessment of the occupational dose

    International Nuclear Information System (INIS)

    Campos, Marcia Pires de

    1999-01-01

    The occupational dose due to inhalation of thoron was assessed through the committed effective dose and the committed equivalent dose received by workers exposed to the radionuclide at the nuclear materials storage site and the thorium purification plant of the Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP). The radiation doses were performed by compartmental analysis following the compartmental model of the lung and biokinetic model of the lead, through the thoron equilibrium equivalent concentrations. These values were obtained by gamma ray spectrometry, total alpha count and alpha particle spectrometry of air samples glass fiber filters. The results of the thoron equilibrium equivalent concentration varied from 0.3 to 0,67 Bq/m 3 at the nuclear materials storage site and from 0.9 to 249.8 Bq/m 3 at the thorium purification plant. The committed effective dose due to thoron inhalation varied from 0.03 mSv/a to 0.67 mSv/a at the nuclear materials storage site and from 0.12 mSv/a to 6.0 mSv/a at the thorium purification plant. The risk assessment of lung cancer and fatal cancers for the workers exposed to thoron at the nuclear materials storage site and the thorium purification plant showed an increment for both risk cancer. (author)

  15. EcoDoses. Improving radiological assessment of doses to man from terrestrial ecosystems: A status report for the NKS-B activity 2006

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, S.; Andersson, K.G. (Technical Univ. of Denmark, Risoe National Lab. for Sustainable Energy, Roskilde (Denmark)); Thoerring, H.; Liland, A. (Norwegian Radiation Protection Authority (Norway)); Joensen, H.P. (Frooskaparsetur Foeroya, Faroe Islands, Torshavn (Denmark)); Isaksson, M. (Goeteborg Univ. (Sweden)); Saxen, R.; Kostiainen, E. (Radiation and Nuclear Safety Authority (STUK) (Finland)); Suolanen, V. (VTT Technical Research Centre of Finland, Espoo (Finland)); Palsson, S.E. (Geislavarnir rikisins (Iceland))

    2009-03-15

    The overall aim of the NKS-B EcoDoses activity is to improve the prediction of doses to humans from consumption of radioactively contaminated food. For this purpose, various published and unpublished datasets have been compiled and applied in developing refined parameterisation for existing food dose models. The ECOSYS model developed in Germany after the Chernobyl accident has been applied as the basis for the investigations. This model can be operated both with discrete releases adequately representing a nuclear power plant accident, and with continuous or multiple releases, as observed in the nuclear weapons testing period. The modelling has revealed that it is essential to ensure that case-specific values are applied for a range of parameters, adequately reflecting the actual conditions with respect to geology, season, climate and demography. In connection with this year's work on the activity, sensitivity studies have been conducted with the ECOSYS model, in which the influence on ingestion dose estimates of a number of parameters has been evaluated in relation to Faroese conditions. The importance of applying location specific data to estimate dose is pinpointed, and it is also concluded that dose predictions for a small and distinct area like the Faroese, where not all of the many parameters required to run ECOSYS optimally have been adequately assessed in recent years, can be associated with considerable uncertainty. A Finnish study has been made in relation to modelling of radiocaesium behaviour in lakes. This study was carried out using a compartmental model that is included as a module in the DETRA dose assessment tool. A total of nine different input parameters (distribution coefficients, run-off from the catchment, erosion from the catchment, sedimentation rate in the lakes, lake water exchange rate, and biological half-lives in four fish species) were varied, and particularly distribution coefficients and lake water exchange rates were

  16. EcoDoses. Improving radiological assessment of doses to man from terrestrial ecosystems: A status report for the NKS-B activity 2006

    International Nuclear Information System (INIS)

    Nielsen, S.; Andersson, K.G.; Thoerring, H.; Liland, A.; Joensen, H.P.; Isaksson, M.; Saxen, R.; Kostiainen, E.; Suolanen, V.; Palsson, S.E.

    2009-03-01

    The overall aim of the NKS-B EcoDoses activity is to improve the prediction of doses to humans from consumption of radioactively contaminated food. For this purpose, various published and unpublished datasets have been compiled and applied in developing refined parameterisation for existing food dose models. The ECOSYS model developed in Germany after the Chernobyl accident has been applied as the basis for the investigations. This model can be operated both with discrete releases adequately representing a nuclear power plant accident, and with continuous or multiple releases, as observed in the nuclear weapons testing period. The modelling has revealed that it is essential to ensure that case-specific values are applied for a range of parameters, adequately reflecting the actual conditions with respect to geology, season, climate and demography. In connection with this year's work on the activity, sensitivity studies have been conducted with the ECOSYS model, in which the influence on ingestion dose estimates of a number of parameters has been evaluated in relation to Faroese conditions. The importance of applying location specific data to estimate dose is pinpointed, and it is also concluded that dose predictions for a small and distinct area like the Faroese, where not all of the many parameters required to run ECOSYS optimally have been adequately assessed in recent years, can be associated with considerable uncertainty. A Finnish study has been made in relation to modelling of radiocaesium behaviour in lakes. This study was carried out using a compartmental model that is included as a module in the DETRA dose assessment tool. A total of nine different input parameters (distribution coefficients, run-off from the catchment, erosion from the catchment, sedimentation rate in the lakes, lake water exchange rate, and biological half-lives in four fish species) were varied, and particularly distribution coefficients and lake water exchange rates were demonstrated to

  17. The assessment of personal dose due to external radiation

    International Nuclear Information System (INIS)

    Boas, J.F.; Young, J.G.

    1990-01-01

    The fundamental basis of thermoluminescent dosimetry (TLD) is discussed and a number of considerations in the measurement of thermoluminescence described, with particular reference to CaSO 4 :Dy. The steps taken to convert a thermoluminescence measurement to an exposure and then an absorbed dose are outlined. The calculation of effective dose equivalents due to external exposure to γ-radiation in a number of situations commonly encountered in a uranium mine is discussed. Factors which may affect the accuracy of external dose assessments are described

  18. Food-chain and dose model, CALDOS, for assessing Canada's Nuclear Fuel Waste Management concept

    International Nuclear Information System (INIS)

    Zach, R.; Sheppard, S.C.

    1991-01-01

    The food-chain and dose model, CALculation of DOSe (CALDOS), was developed for assessing Canada's concept for nuclear fuel waste disposal in a vault deep in crystalline rock of the Canadian Shield. The model is very general and based on the Shield as a whole. The critical group is totally self-sufficient and represented by ICRP (1975) Reference Man for dose prediction. CALDOS assumes steady-state conditions and deals with variation and uncertainty through Monte Carlo simulation techniques. Ingrowth of some radioactive daughters is considered during food-chain transfer. A limit is set on root uptake to avoid unrealistic plant concentrations. Integrated ingestion and inhalation rates of man are calculated in a unique way, based on energy needs. Soil ingestion by man and external exposure from building material are unique pathways considered. Tritium, 129 I, and 222 Rn are treated through special models, and 14 C and 129 I involve unique geosphere dose limits. All transfer coefficients are lognormally distributed, and the plant/soil concentration ratio is correlated with the soil partition coefficient. Animals' ingestion rates are normally distributed and correlated with each other. Comprehensive sets of internal and external dose conversion factors were calculated for CALDOS. Sample calculations show that dose distributions tend to be strongly right-skewed. Many features of CALDOS are relevant for environmental assessment in general

  19. Assessment of dose received by organ in lumbosacral examination

    International Nuclear Information System (INIS)

    Eltyeib, Nashwa Kheirallah

    2014-11-01

    The biological damage produced by radiation is closely related to the amount of energy absorbed in the case x- rays. Measurement of produced ionizing provides a useful assessment of the total energy absorbed. This study was performed in Khartoum Teaching Hospital in period of January to June 2014. This study was performed to assess the effective dose (ED) received in lumbosacral radiography examination and to analyze effective dose distributions among radiological department under study. The study was performed in Khartoum Teaching Hospital, covering two x-ray units and a sample of 50 patients. The following parameters were recorded: age weight, height, body mass index (BMI) derived from mass (kg) and (height. (m)) and exposure factors. The dose was measured for lumbosacral x- rays examination. For effective dose calculation, the entrance surface dose (ESD) values were estimated from the x-ray tube output parameters for lumbosacral spine A P and lateral examinations. The ED values were then calculated from the obtained ESD values using IAEA calculation methods. Effective doses were than calculated from energy imported using ED conversion factors by IAEA. The results of ED values calculated showed that patient exposures were within the normal range of exposure. The mean ED values calculated were (2.49 ±0.03) mGy and (5.5.60 ± 0.0.22) mGy for Lumbosacral spine A P and lateral examinations, respectively. Further studies are recommended with more number of patients and using more modalities for comparison.(Author)

  20. Cytogenetic analysis for radiation dose assessment. A manual

    International Nuclear Information System (INIS)

    2001-01-01

    Chromosome aberration analysis is recognized as a valuable dose assessment method which fills a gap in dosimetric technology, particularly when there are difficulties in interpreting the data, in cases where there is reason to believe that persons not wearing dosimeters have been exposed to radiation, in cases of claims for compensation for radiation injuries that are not supported by unequivocal dosimetric evidence, or in cases of exposure over an individual's working lifetime. The IAEA has maintained a long standing involvement in biological dosimetry commencing in 1978. This has been via a sequence of Co-ordinated Research Programmes (CRPs), the running of Regional Training Courses, the sponsorship of individual training fellowships and the provision of necessary equipment to laboratories in developing Member States. The CRP on the 'Use of Chromosome Aberration Analysis in Radiation Protection' was initiated by IAEA in 1982. It ended with the publication of the IAEA Technical Report Series No. 260, titled 'Biological Dosimetry: Chromosomal Aberration Analysis for Dose Assessment' in 1986. The overall objective of the CRP (1998-2000) on 'Radiation Dosimetry through Biological Indicators' is to review and standardize the available methods and amend the above mentioned previous IAEA publication with current techniques on cytogenetic bioindicators which may be of practical use in biological dosimetry worldwide. An additional objective is to identify promising cytogenetic techniques to provide Member States with up to date and generally agreed advice regarding the best focus for research and suggestions for the most suitable techniques for near future practice in biodosimetry. This activity is in accordance with the International Basic Safety Standards (BSS) published in 1996. To pursue this task the IAEA has conducted a Research Co-ordination Meeting (Budapest, Hungary, June 1998) with the participation of senior scientists of 24 biodosimetry laboratories to discuss

  1. Assessment of CT dose to the fetus and pregnant female patient using patient-specific computational models

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Tianwu; Poletti, Pierre-Alexandre; Platon, Alexandra; Becker, Christoph D. [Geneva University Hospital, Department of Medical Imaging and Information Sciences, Geneva (Switzerland); Zaidi, Habib [Geneva University Hospital, Department of Medical Imaging and Information Sciences, Geneva (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland); University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, University of Groningen, Groningen (Netherlands); University of Southern Denmark, Department of Nuclear Medicine, Odense (Denmark); Geneva University Hospital, Division of Nuclear Medicine and Molecular Imaging, Geneva (Switzerland)

    2018-03-15

    This work provides detailed estimates of the foetal dose from diagnostic CT imaging of pregnant patients to enable the assessment of the diagnostic benefits considering the associated radiation risks. To produce realistic biological and physical representations of pregnant patients and the embedded foetus, we developed a methodology for construction of patient-specific voxel-based computational phantoms based on existing standardised hybrid computational pregnant female phantoms. We estimated the maternal absorbed dose and foetal organ dose for 30 pregnant patients referred to the emergency unit of Geneva University Hospital for abdominal CT scans. The effective dose to the mother varied from 1.1 mSv to 2.0 mSv with an average of 1.6 mSv, while commercial dose-tracking software reported an average effective dose of 1.9 mSv (range 1.7-2.3 mSv). The foetal dose normalised to CTDI{sub vol} varies between 0.85 and 1.63 with an average of 1.17. The methodology for construction of personalised computational models can be exploited to estimate the patient-specific radiation dose from CT imaging procedures. Likewise, the dosimetric data can be used for assessment of the radiation risks to pregnant patients and the foetus from various CT scanning protocols, thus guiding the decision-making process. (orig.)

  2. Assessment of eye lens doses for workers during interventional radiology procedures

    International Nuclear Information System (INIS)

    Urboniene, A.; Sadzeviciene, E.; Ziliukas, J.

    2015-01-01

    The assessment of eye lens doses for workers during interventional radiology (IR) procedures was performed using a new eye lens dosemeter. In parallel, the results of routine individual monitoring were analysed and compared with the results obtained from measurements with a new eye lens dosemeter. The eye lens doses were assessed using H p (3) measured at the level of the eyes and were compared with H p (10) measured with the whole-body dosemeter above the lead collar. The information about use of protective measures, the number of performed interventional procedures per month and their fluoroscopy time was also collected. The assessment of doses to the lens of the eye was done for 50 IR workers at 9 Lithuanian hospitals for the period of 2012-2013. If the use of lead glasses is not taken into account, the estimated maximum annual dose equivalent to the lens of the eye was 82 mSv. (authors)

  3. Re-assessment of dose from the Vinten extremity dosemeter

    International Nuclear Information System (INIS)

    O'Hagan, J.B.; Pearson, A.J.; Dutt, J.C.

    1989-01-01

    A procedure is described for re-assessing the dose from the Vinten extremity dosemeter using phototransferred thermoluminescence. The technique produces a linear response up to 50 Sv. The re-assessment efficiency is approximately 10% for the first re-assessment and 3-5% for the second re-assessment. The detection threshold values (at the 95% confidence level) are 3 mSv and 9 mSv respectively. (author)

  4. Dose assessment in environmental radiological protection: State of the art and perspectives.

    Science.gov (United States)

    Stark, Karolina; Goméz-Ros, José M; Vives I Batlle, Jordi; Lindbo Hansen, Elisabeth; Beaugelin-Seiller, Karine; Kapustka, Lawrence A; Wood, Michael D; Bradshaw, Clare; Real, Almudena; McGuire, Corynne; Hinton, Thomas G

    2017-09-01

    Exposure to radiation is a potential hazard to humans and the environment. The Fukushima accident reminded the world of the importance of a reliable risk management system that incorporates the dose received from radiation exposures. The dose to humans from exposure to radiation can be quantified using a well-defined system; its environmental equivalent, however, is still in a developmental state. Additionally, the results of several papers published over the last decade have been criticized because of poor dosimetry. Therefore, a workshop on environmental dosimetry was organized by the STAR (Strategy for Allied Radioecology) Network of Excellence to review the state of the art in environmental dosimetry and prioritize areas of methodological and guidance development. Herein, we report the key findings from that international workshop, summarise parameters that affect the dose animals and plants receive when exposed to radiation, and identify further research needs. Current dosimetry practices for determining environmental protection are based on simple screening dose assessments using knowledge of fundamental radiation physics, source-target geometry relationships, the influence of organism shape and size, and knowledge of how radionuclide distributions in the body and in the soil profile alter dose. In screening model calculations that estimate whole-body dose to biota the shapes of organisms are simply represented as ellipsoids, while recently developed complex voxel phantom models allow organ-specific dose estimates. We identified several research and guidance development priorities for dosimetry. For external exposures, the uncertainty in dose estimates due to spatially heterogeneous distributions of radionuclide contamination is currently being evaluated. Guidance is needed on the level of dosimetry that is required when screening benchmarks are exceeded and how to report exposure in dose-effect studies, including quantification of uncertainties. Further

  5. Dose and risk assessment approach for the Fernald CERCLA D ampersand D Project

    International Nuclear Information System (INIS)

    Throckmorton, J.D.; Clark, T.R.; Waligora, S.J. Jr.; Haaker, R.F.

    1994-01-01

    At the Fernald Environmental Management Project (FEMP) the uranium processing facilities used from the 1952 through 1989 are near or beyond their intended design life. These current conditions present an increasing probability for future releases of hazardous substances to the environment. To support a decision by the U.S. Department of Energy (DOE) and the Environmental Protection Agency (EPA) to remediate the buildings, a dose and risk assessment was performed to determine the extent of exposure that would be associated with the controlled decontamination and dismantlement (D ampersand D) of the Fernald facilities. A conceptual risk assessment model was developed, with exposure mechanisms and associated pathways for each potential receptor. The three receptor groups were defined as: the remediation workers, other on-site workers (those not performing D ampersand D), and off-site residents. For use in the conceptual model, an airborne source term was developed through process knowledge, other historical information and data, and air sample data from within the facilities. Individual and collective doses and risks were developed for each receptor and for each population group. The risk assessment demonstrated that all exposures resulting from the action would be within the acceptable DOE administrative control level of 2.0 rem per year for occupational workers and the acceptable EPA risk range from 10 -6 to 10 -4 for the general public

  6. Uncertainty of fast biological radiation dose assessment for emergency response scenarios.

    Science.gov (United States)

    Ainsbury, Elizabeth A; Higueras, Manuel; Puig, Pedro; Einbeck, Jochen; Samaga, Daniel; Barquinero, Joan Francesc; Barrios, Lleonard; Brzozowska, Beata; Fattibene, Paola; Gregoire, Eric; Jaworska, Alicja; Lloyd, David; Oestreicher, Ursula; Romm, Horst; Rothkamm, Kai; Roy, Laurence; Sommer, Sylwester; Terzoudi, Georgia; Thierens, Hubert; Trompier, Francois; Vral, Anne; Woda, Clemens

    2017-01-01

    Reliable dose estimation is an important factor in appropriate dosimetric triage categorization of exposed individuals to support radiation emergency response. Following work done under the EU FP7 MULTIBIODOSE and RENEB projects, formal methods for defining uncertainties on biological dose estimates are compared using simulated and real data from recent exercises. The results demonstrate that a Bayesian method of uncertainty assessment is the most appropriate, even in the absence of detailed prior information. The relative accuracy and relevance of techniques for calculating uncertainty and combining assay results to produce single dose and uncertainty estimates is further discussed. Finally, it is demonstrated that whatever uncertainty estimation method is employed, ignoring the uncertainty on fast dose assessments can have an important impact on rapid biodosimetric categorization.

  7. The remobilisation of radionuclides from marine sediments: implications for collective dose assessments

    International Nuclear Information System (INIS)

    Nicholson, S.; MacKenzie, J.

    1988-09-01

    A model of the transfer (in either direction) of radioactivity between seawater and the seabed is described. It was developed, in the first instance, for inclusion in marine collective dose assessment codes. A review of radionuclide-sediment interactions with particular emphasis on the remobilisation process is followed by a description of the seabed model, an investigation of the effect of the model on estimates of collective dose, and a discussion of sedimentation in the Irish Sea in the context of radioactive discharges. The inclusion of the seabed model may lead to marked decreases in the collective dose at short integration times for nuclides with a high affinity for sediments. For discharges of such radionuclides into the Irish Sea, remobilisation may lead to a significant increase in collective dose compared with estimates obtained ignoring this phenomenon; and thirdly, remobilisation appears to have little effect on collective doses integrated to infinite time for discharges from three other locations in the UK. It is also shown that inclusion of the seabed model leads to predictions of a high uptake of plutonium by the seabed for Irish Sea discharges without the need for anomalously high sedimentation rates. (author)

  8. The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations

    Science.gov (United States)

    Gu, J.; Bednarz, B.; Caracappa, P. F.; Xu, X. G.

    2009-05-01

    The latest multiple-detector technologies have further increased the popularity of x-ray CT as a diagnostic imaging modality. There is a continuing need to assess the potential radiation risk associated with such rapidly evolving multi-detector CT (MDCT) modalities and scanning protocols. This need can be met by the use of CT source models that are integrated with patient computational phantoms for organ dose calculations. Based on this purpose, this work developed and validated an MDCT scanner using the Monte Carlo method, and meanwhile the pregnant patient phantoms were integrated into the MDCT scanner model for assessment of the dose to the fetus as well as doses to the organs or tissues of the pregnant patient phantom. A Monte Carlo code, MCNPX, was used to simulate the x-ray source including the energy spectrum, filter and scan trajectory. Detailed CT scanner components were specified using an iterative trial-and-error procedure for a GE LightSpeed CT scanner. The scanner model was validated by comparing simulated results against measured CTDI values and dose profiles reported in the literature. The source movement along the helical trajectory was simulated using the pitch of 0.9375 and 1.375, respectively. The validated scanner model was then integrated with phantoms of a pregnant patient in three different gestational periods to calculate organ doses. It was found that the dose to the fetus of the 3 month pregnant patient phantom was 0.13 mGy/100 mAs and 0.57 mGy/100 mAs from the chest and kidney scan, respectively. For the chest scan of the 6 month patient phantom and the 9 month patient phantom, the fetal doses were 0.21 mGy/100 mAs and 0.26 mGy/100 mAs, respectively. The paper also discusses how these fetal dose values can be used to evaluate imaging procedures and to assess risk using recommendations of the report from AAPM Task Group 36. This work demonstrates the ability of modeling and validating an MDCT scanner by the Monte Carlo method, as well as

  9. The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations

    International Nuclear Information System (INIS)

    Gu, J; Bednarz, B; Caracappa, P F; Xu, X G

    2009-01-01

    The latest multiple-detector technologies have further increased the popularity of x-ray CT as a diagnostic imaging modality. There is a continuing need to assess the potential radiation risk associated with such rapidly evolving multi-detector CT (MDCT) modalities and scanning protocols. This need can be met by the use of CT source models that are integrated with patient computational phantoms for organ dose calculations. Based on this purpose, this work developed and validated an MDCT scanner using the Monte Carlo method, and meanwhile the pregnant patient phantoms were integrated into the MDCT scanner model for assessment of the dose to the fetus as well as doses to the organs or tissues of the pregnant patient phantom. A Monte Carlo code, MCNPX, was used to simulate the x-ray source including the energy spectrum, filter and scan trajectory. Detailed CT scanner components were specified using an iterative trial-and-error procedure for a GE LightSpeed CT scanner. The scanner model was validated by comparing simulated results against measured CTDI values and dose profiles reported in the literature. The source movement along the helical trajectory was simulated using the pitch of 0.9375 and 1.375, respectively. The validated scanner model was then integrated with phantoms of a pregnant patient in three different gestational periods to calculate organ doses. It was found that the dose to the fetus of the 3 month pregnant patient phantom was 0.13 mGy/100 mAs and 0.57 mGy/100 mAs from the chest and kidney scan, respectively. For the chest scan of the 6 month patient phantom and the 9 month patient phantom, the fetal doses were 0.21 mGy/100 mAs and 0.26 mGy/100 mAs, respectively. The paper also discusses how these fetal dose values can be used to evaluate imaging procedures and to assess risk using recommendations of the report from AAPM Task Group 36. This work demonstrates the ability of modeling and validating an MDCT scanner by the Monte Carlo method, as well as

  10. Assessment of dose inhomogeneity at target level by in vivo dosimetry

    International Nuclear Information System (INIS)

    Leunens, G.; Verstraete, J.; Dutreix, A.; Schueren, E. van der

    1992-01-01

    Inhomogeneity of dose delivered to the target volume due to irregular body surface and tissue densities remains in many cases unknown, since dose distribution is calculated for most radiation treatments in only one transverse section and assuming the patient to be water equivalent. In this study transmission and target absorbed dose homogeneity is assessed for 11 head-and-neck cancer treatments by in vivo measurements with silicon diodes. Besides the dose to specification point, the dose delivered to 2-4 off-axis points in midline sagittal plane is estimated from entrance and exit dose measurements. Simultaneously made portal films allow to identify anatomical structures passed by the beam before reaching exit diode. Mean deviation from expected transmission is -6.8% for bone, +6% for air cavities and -2.5% for soft tissue. At midplane, mean deviations from expected target dose are respectively -3.5%, +2.3% and -1.9%. Deviations from prescribed dose are larger than 5% in 12/39 target points. Accuracy requirements in target dose delivery of plus or minus 5%, as proposed by ICRU, cannot be fulfilled in 7/11 patients and is mostly due to irregular body contour and tissue densities. as only a limited number of points are considered, inhomogeneity in dose delivered throughout whole irradiated volume is underestimated, as is illustrated from exit dose profiles obtained from portal image. Besides its tremendous value as a quality assurance procedure, in vivo dose measurements are shown to be a valid method for assessing dose delivered to irradiated tissues when dose computations are assumed to be inaccurate or even impossible in current practice. (author). 21 refs., 8 figs., 1 tab

  11. Assessment of CT dose to the fetus and pregnant female patient using patient-specific computational models

    DEFF Research Database (Denmark)

    Xie, Tianwu; Poletti, Pierre-Alexandre; Platon, Alexandra

    2018-01-01

    of pregnant patients and the embedded foetus, we developed a methodology for construction of patient-specific voxel-based computational phantoms based on existing standardised hybrid computational pregnant female phantoms. We estimated the maternal absorbed dose and foetal organ dose for 30 pregnant patients...... for assessment of the radiation risks to pregnant patients and the foetus from various CT scanning protocols, thus guiding the decision-making process. KEY POINTS: • In CT examinations, the absorbed dose is non-uniformly distributed within foetal organs. • This work reports, for the first time, estimates...

  12. Assessment of genetically significant doses to the Sofia population from natural gamma background

    International Nuclear Information System (INIS)

    Vasilev, G.; Khristova, M.

    1977-01-01

    Genetically significant dose to the population of Sofia city was assessed within a program covering larger urban communities in the country. Measurements were made of gamma background exposure rates in the gonadal region. Gonad doses were estimated using a screening factor of 0.73. Based on statistical data for total number of inhabitants and number of people of reproductive age, and on the mean annual gonad doses derived, calculations were made of genetically significant dose to the Sofia population. Base-line data were thus provided for an assessment of extra radiation dose resulting from occupational radiation exposure. (author)

  13. Improvement of the following accident dose assessment system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Enn Han; Han, Moon Hee; Suh, Kyung Suk; Hwang, Won Tae; Choi, Young Gil [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1999-12-15

    The FADAS has been updates for calculating the real-time wind fields continuously at the nuclear sites in Korea. The system has been constructed to compute the wind fields using its own process for the dummy meteorological data, and dose not effect on the overall wind field module. If the radioactive materials are released into the atmosphere in real situation, the calculations of wind fields and exposure dose in the previous FADAS are performed in the case of the recognition of the above situation in the source term evaluation module. The current version of FADAS includes the program for evaluating the effect of the predicted accident and the assumed scenario together. The dose assessment module is separated into the real-time and the supposed accident respectively.

  14. Evaluation of the dose assessment models for routine radioactive releases to the environment

    International Nuclear Information System (INIS)

    Rossi, J.

    1998-05-01

    The aim of the work was to evaluate the needs of development concerning the dose calculation models for routine releases and application of the models for exceptional release situations at the NPP plants operated by Imatran Voima Ltd. and Teollisuuden Voima Ltd. in Finland. First, the differences of the calculation models concerning input data, models themselves and output are considered. Subsequently some single features like importance of nuclides in exposure pathways due to change of the release composition, dose calculation for children and importance of time period of particle releases are considered. The existing dose calculation model used by the radiation safety authorities is aimed at a tool for checking the results from calculations of doses arising from routine releases by the power companies. Characteristics of an independent, foreign model and its suitability for safety authorities for dose calculations of releases in normal operation is also assessed. The needs of improvements in the existing calculation models and characteristics of a comprehensive model for safety authorities are discussed as well

  15. Internal dose assessment data management system for a large population of Pu workers

    International Nuclear Information System (INIS)

    Bertelli, L.; Miller, G.; Little, T.; Guilmette, R.A.; Glasser, S.M.

    2007-01-01

    This paper describes the design and implementation of the Los Alamos National Laboratory (LANL) dose assessment (DA) data system. Dose calculations for the most important radionuclides at LANL, namely plutonium, americium, uranium and tritium, are performed through the Microsoft Access DA database. DA includes specially developed forms and macros that perform a variety of tasks, such as retrieving bioassay data, launching the FORTRAN internal dosimetry applications and displaying dose results in the form of text summaries and plots. The DA software involves the following major processes: (1) downloading of bioassay data from a remote data source, (2) editing local and remote databases, (3) setting up and carrying out internal dose calculations using the UF code or the ID code, (3) importing results of the dose calculations into local results databases, (4) producing a secondary database of 'official results' and (5) automatically creating and e-mailing reports. The software also provides summary status and reports of the pending DAs, which are useful for managing the cases in process. (authors)

  16. Assessment of internal doses in emergency situations

    Energy Technology Data Exchange (ETDEWEB)

    Rahola, T.; Muikku, M. [Radiation and Nuclear Safety Authority - STUK (Finland); Falk, R.; Johansson, J. [Swedish Radiation Protection Authority - SSI (Sweden); Liland, A.; Thorshaug, S. [NRPA (Norway)

    2006-04-15

    The need for assessing internal radiation doses in emergency situations was demonstrated after accidents in Brazil, Ukraine and other countries. Lately more and more concern has been expressed regarding malevolent use of radiation and radioactive materials. The scenarios for such use are more difficult to predict than for nuclear power plant or weapons accidents. Much of the results of the work done in the IRADES project can be adopted for use in various accidental situations involving radionuclides that are not addressed in this report. If an emergency situation occurs in only one or a few of the Nordic countries, experts from the other countries could be called upon to assist in monitoring. A big advantage is then our common platform. In the Nordic countries much work has been put down on quality assurance of measurements and on training of dose assessment calculations. Attention to this was addressed at the internal dosimetry course in October 2005. Nordic emergency preparedness exercises have so far not included training of direct measurements of people in the early phase of an emergency. The aim of the IRADES project was to improve the preparedness especially for thyroid measurements. The modest financial support did not enable the participants to make big efforts but certainly acted as a much appreciated reminder of the importance of being prepared also to handle situations with malevolent use of radioactive materials. It was left to each country to decide to which extent to improve the practical skills. There is still a need for detailed national implementation plans. Measurement strategies need to be developed in each country separately taking into account national regulations, local circumstances and resources. End users of the IRADES report are the radiation protection authorities. (au)

  17. Assessment of internal doses in emergency situations

    International Nuclear Information System (INIS)

    Rahola, T.; Muikku, M.; Falk, R.; Johansson, J.; Liland, A.; Thorshaug, S.

    2006-04-01

    The need for assessing internal radiation doses in emergency situations was demonstrated after accidents in Brazil, Ukraine and other countries. Lately more and more concern has been expressed regarding malevolent use of radiation and radioactive materials. The scenarios for such use are more difficult to predict than for nuclear power plant or weapons accidents. Much of the results of the work done in the IRADES project can be adopted for use in various accidental situations involving radionuclides that are not addressed in this report. If an emergency situation occurs in only one or a few of the Nordic countries, experts from the other countries could be called upon to assist in monitoring. A big advantage is then our common platform. In the Nordic countries much work has been put down on quality assurance of measurements and on training of dose assessment calculations. Attention to this was addressed at the internal dosimetry course in October 2005. Nordic emergency preparedness exercises have so far not included training of direct measurements of people in the early phase of an emergency. The aim of the IRADES project was to improve the preparedness especially for thyroid measurements. The modest financial support did not enable the participants to make big efforts but certainly acted as a much appreciated reminder of the importance of being prepared also to handle situations with malevolent use of radioactive materials. It was left to each country to decide to which extent to improve the practical skills. There is still a need for detailed national implementation plans. Measurement strategies need to be developed in each country separately taking into account national regulations, local circumstances and resources. End users of the IRADES report are the radiation protection authorities. (au)

  18. Preliminary assessment of the dose to the interventional radiologist in fluoro-CT-guided procedures

    International Nuclear Information System (INIS)

    Pereira, M. F.; Alves, J. G.; Sarmento, S.; Santos, J. A. M.; Sousa, M. J.; Gouvea, M.; Oliveira, A. D.; Cardoso, J. V.; Santos, L. M.

    2011-01-01

    A preliminary assessment of the occupational dose to the intervention radiologist received in fluoroscopy computerised tomography (CT) used to guide the collection of lung and bone biopsies is presented. The main aim of this work was to evaluate the capability of the reading system as well as of the available whole-body (WB) and extremity dosemeters used in routine monthly monitoring periods to measure per procedure dose values. The intervention radiologist was allocated 10 WB detectors (LiF: Mg, Ti, TLD-100) placed at chest and abdomen levels above and below the lead apron, and at both right and left arms, knees and feet. A special glove was developed with casings for the insertion of 11 extremity detectors (LiF:Mg, Cu, P, TLD-100H) for the identification of the most highly exposed fingers. The H p (10) dose values received above the lead apron (ranged 0.20-0.02 mSv) depend mainly on the duration of the examination and on the placement of physician relative to the beam, while values below the apron are relatively low. The left arm seems to receive a higher dose value. H p (0.07) values to the hand (ranged 36.30-0.06 mSv) show that the index, middle and ring fingers are the most highly exposed. In this study, the wrist dose was negligible compared with the finger dose. These results are preliminary and further studies are needed to better characterise the dose assessment in CT fluoroscopy. (authors)

  19. Monitoring of high-radiation areas for the assessment of operational and body doses

    International Nuclear Information System (INIS)

    Chen, T.J.; Tung, C.J.; Yeh, W.W.; Liao, R.Y.

    2004-01-01

    The International Commission on Radiological Protection (ICRP) recommended a system of dose limits for the protection of ionizing radiation. This system was established based on the effective dose, E, and the equivalent dose to an organ or tissue, H T , to assess stochastic and deterministic effects. In radiation protection monitoring for external radiation, operational doses such as the deep dose equivalent index, H I,d , shallow dose equivalent index, H I,s , ambient dose equivalent [1,4-6], H*, directional dose equivalent, H', individual dose equivalent-penetrating, H p , and individual dose equivalent-superficial, H s , are implemented. These quantities are defined in an International Commission on Radiation Units and Measurements (ICRU) sphere and in an anthropomorphic phantom under simplified irradiation conditions. They are useful when equivalent doses are below the corresponding limits. In the case of equivalent doses far below the limits, the exposure or air kerma is commonly applied. For workers exposed to high levels of radiation, accurate assessments of effective doses and equivalent doses may be needed in order to acquire legal and health information. In the general principles of monitoring for radiation protection of workers, ICRP recommended that: 'A graduated response is advocated for the monitoring of the workplace and for individual monitoring - graduated in the sense that a greater degree of monitoring is deemed to be necessary as doses increase of as unpredictability increases. Gradually more complex or realistic procedures should be adopted as doses become higher. Thus, at low dose equivalents (corresponding say to those within Working Condition B) dosimetric quantities might be used directly to assess exposure, since accuracy is not crucial. At intermediate dose equivalents (corresponding say to Working Condition A and slight overexposures) somewhat greater accuracy is warranted, and the conversion coefficients from dosimetric to radiation

  20. Assessing Doses to Interventional Radiologists Using a Personal Dosimeter Worn Over a Protective Apron

    Energy Technology Data Exchange (ETDEWEB)

    Stranden, E.; Widmark, A.; Sekse, T. (Buskerud Univ. College, Drammen (Norway))

    2008-05-15

    Background: Interventional radiologists receive significant radiation doses, and it is important to have simple methods for routine monitoring of their exposure. Purpose: To evaluate the usefulness of a dosimeter worn outside the protective apron for assessments of dose to interventional radiologists. Material and Methods: Assessments of effective dose versus dose to dosimeters worn outside the protective apron were achieved by phantom measurements. Doses outside and under the apron were assessed by phantom measurements and measurements on eight radiologists wearing two routine dosimeters for a 2-month period during ordinary working conditions. Finger doses for the same radiologists were recorded using thermoluminescent dosimeters (TLD; DXT-RAD Extremity dosimeters). Results: Typical values for the ratio between effective dose and dosimeter dose were found to be about 0.02 when the radiologist used a thyroid shield and about 0.03 without. The ratio between the dose to the dosimeter under and outside a protective apron was found to be less than 0.04. There was very good correlation between finger dose and dosimeter dose. Conclusion: A personal dosimeter worn outside a protective apron is a good screening device for dose to the eyes and fingers as well as for effective dose, even though the effective dose is grossly overestimated. Relatively high dose to the fingers and eyes remains undetected by a dosimeter worn under the apron

  1. Assessing Doses to Interventional Radiologists Using a Personal Dosimeter Worn Over a Protective Apron

    International Nuclear Information System (INIS)

    Stranden, E.; Widmark, A.; Sekse, T.

    2008-01-01

    Background: Interventional radiologists receive significant radiation doses, and it is important to have simple methods for routine monitoring of their exposure. Purpose: To evaluate the usefulness of a dosimeter worn outside the protective apron for assessments of dose to interventional radiologists. Material and Methods: Assessments of effective dose versus dose to dosimeters worn outside the protective apron were achieved by phantom measurements. Doses outside and under the apron were assessed by phantom measurements and measurements on eight radiologists wearing two routine dosimeters for a 2-month period during ordinary working conditions. Finger doses for the same radiologists were recorded using thermoluminescent dosimeters (TLD; DXT-RAD Extremity dosimeters). Results: Typical values for the ratio between effective dose and dosimeter dose were found to be about 0.02 when the radiologist used a thyroid shield and about 0.03 without. The ratio between the dose to the dosimeter under and outside a protective apron was found to be less than 0.04. There was very good correlation between finger dose and dosimeter dose. Conclusion: A personal dosimeter worn outside a protective apron is a good screening device for dose to the eyes and fingers as well as for effective dose, even though the effective dose is grossly overestimated. Relatively high dose to the fingers and eyes remains undetected by a dosimeter worn under the apron

  2. Development of Software for dose Records Data Base Access

    International Nuclear Information System (INIS)

    Amaro, M.

    1990-01-01

    The CIEMAT personal dose records are computerized in a Dosimetric Data Base whose primary purpose was the individual dose follow-up control and the data handling for epidemiological studies. Within the Data Base management scheme, software development to allow searching of individual dose records by external authorised users was undertaken. The report describes the software developed to allow authorised persons to visualize on screen a summary of the individual dose records from workers included in the Data Base. The report includes the User Guide for the authorised list of users and listings of codes and subroutines developed. (Author) 2 refs

  3. Overview of Dose Assessment Developments and the Health of Riverside Residents Close to the “Mayak” PA Facilities, Russia

    Directory of Open Access Journals (Sweden)

    William J.F. Standring

    2009-01-01

    Full Text Available The Norwegian Radiation Protection Authority (NRPA has been involved in studies related to the Mayak PA and the consequences of activities undertaken at the site for a number of years. This paper strives to present an overview of past and present activities at the Mayak PA and subsequent developments in the quantification of health effects on local populations caused by discharges of radioactive waste into the Techa River. Assessments of doses to affected populations have relied on the development of dose reconstruction techniques for both external and internal doses. Contamination levels are typically inhomogeneous and decrease with increasing distance from the discharge point. Citations made in this paper give a comprehensive, though not exhaustive, basis for further reading about this topic.

  4. The assessment of the carcinogenic effects of low dose radiation

    International Nuclear Information System (INIS)

    Tubiana, M.; Lafuma, J.; Masse, R.; Latarjet, R.

    1991-01-01

    It is concluded that the exclusion of patients for the purposes of risk estimation, the choice of a particular relative risk projection model and of a dose reduction factor equal to 2 are all decisions which result in an overestimation of the actual risk. These choices can be understood when the aim is radiation protection and when it is safer to overestimate the risk; however, they are open to criticism if the aim is a realistic assessment of the risk. For low doses, below 50 mSv/year, and when all causes of uncertainty are added, the actual risk might be markedly lower than the risk estimated with the ICRP (1991) carcinogenic risk coefficient and the DRF estimated by ICRP. Future studies should aim at providing direct and more precise assessments of risk coefficients in the low dose region. (Author)

  5. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Taeko; Morishima, Hiroshige [Kinki Univ., Atomic Energy Research Institute, Osaka (Japan); Tatsumi, Kusuo [Kinki Univ., Life Science Research Institute, Osaka (Japan); Nakai, Sayaka; Sugahara, Tsutomu [Health Research Foundation, Kyoto (Japan); Yuan Yongling [Labor Hygiene Institute of Hunan Prov. (China); Wei Luxin [Laboratory of Industorial Hygiene, Ministry of Health (China)

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: (1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. (2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  6. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    International Nuclear Information System (INIS)

    Koga, Taeko; Morishima, Hiroshige; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: 1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. 2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  7. Radiological dose assessment from the operation of Daeduk nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Won Tae; Kim, Eun Han; Suh, Kyung Suk; Choi, Young Gil [Korea Atomic Energy Research Institute, Taejon (Korea)

    2000-02-01

    The objective of this project is to assure the public acceptance for nuclear facilities, and the environmental safety from the operation of Daeduk nuclear facilities, such as HANARO research reactor, nuclear fuel processing facilities and others. For identifying the integrity of their facilities, the maximum individual doses at the site boundary and on the areas with high population density were assessed. Also, the collective doses within radius 80 km from the site were assessed. The radiation impacts for residents around the site from the operation of Daeduk nuclear facilities in 1999 were neglectable. 8 refs., 10 figs., 27 tabs. (Author)

  8. Thermoluminescence dosemeter for personal dose equivalent assessment

    International Nuclear Information System (INIS)

    Silva, T.A. da; Rosa, L.A.R. da; Campos, L.L.

    1995-01-01

    The possibility was investigated of utilising a Brazilian thermoluminescence individual dosemeter, usually calibrated in terms of photon dose equivalent, for the assessment of the personal dose equivalent, H p (d), at depths of 0.07 and 10 mm. The dosemeter uses four CaSO 4 :Dy thermoluminescent detectors, between different filters, as the sensitive materials. It was calibrated in gamma and X radiation fields in the energy range from 17 to 1250 keV. Linear combinations of the responses of three detectors, in this energy range, allow the evaluation of H p (0.07) and H p (10), for radiation incidence angles varying from 0 to 60 degrees, with an accuracy better than 35%. The method is not applicable to mixed photon-beta fields. (author)

  9. Environmental dose rate assessment of ITER using the Monte Carlo method

    Directory of Open Access Journals (Sweden)

    Karimian Alireza

    2014-01-01

    Full Text Available Exposure to radiation is one of the main sources of risk to staff employed in reactor facilities. The staff of a tokamak is exposed to a wide range of neutrons and photons around the tokamak hall. The International Thermonuclear Experimental Reactor (ITER is a nuclear fusion engineering project and the most advanced experimental tokamak in the world. From the radiobiological point of view, ITER dose rates assessment is particularly important. The aim of this study is the assessment of the amount of radiation in ITER during its normal operation in a radial direction from the plasma chamber to the tokamak hall. To achieve this goal, the ITER system and its components were simulated by the Monte Carlo method using the MCNPX 2.6.0 code. Furthermore, the equivalent dose rates of some radiosensitive organs of the human body were calculated by using the medical internal radiation dose phantom. Our study is based on the deuterium-tritium plasma burning by 14.1 MeV neutron production and also photon radiation due to neutron activation. As our results show, the total equivalent dose rate on the outside of the bioshield wall of the tokamak hall is about 1 mSv per year, which is less than the annual occupational dose rate limit during the normal operation of ITER. Also, equivalent dose rates of radiosensitive organs have shown that the maximum dose rate belongs to the kidney. The data may help calculate how long the staff can stay in such an environment, before the equivalent dose rates reach the whole-body dose limits.

  10. Variability in dose-equivalent assessments for inhaled U3O8 concentrations

    International Nuclear Information System (INIS)

    Hewson, G.; Blyth, D.I.

    1985-01-01

    A potentially significant radiological hazard exists in the packaging area of uranium mills through the inhalation of airborne uranium octoxide (U 3 O 8 ). The Radiation Protection (Mining and Milling Code (1980) requires the measurement and assessment of quarterly, annual and cumulative dose equivalents for employees working in these areas. Arising through differences which exist between the abovementioned Code and ICRP 30, and assumptions of particle size and dust concentration distributions, confusion exists within Australia regarding the methods which can be used to make the required assessments. Exposure data were collected during routine monitoring at an operating mill facility and were interpreted using different methods and a range of assumptions. Results indicated the dust at this facility is characterised by an AMAD greater than 10 μ, and dust concentrations were distributed lognormally. Assumptions of a normal distribution may result in an overestimate of the dose equivalent. The importance of particle size in dose assessments using ICRP 30 techniques was highlighted. Information was masked when employee data was grouped to provide work category dose assessments. The use of ICRP 30 methods were recommended to provide uniformity throughout Australia

  11. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    International Nuclear Information System (INIS)

    Braby, L. A.; Reece, W. D.; Hsu, W. H.

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation experiments. We have also developed 4.3 mm diameter ion chambers with both tissue equivalent and carbon walls for the purpose of measuring dose mean lineal energy due to all radiations and due to all radiations except neutrons, respectively. By adjusting the gas pressure in the ion chamber, it can be made to simulate tissue volumes from a few nanometers to a few millimeters in diameter. The charge is integrated for 0.1 seconds, and the resulting pulse height is recorded by a multi channel analyzer. The system has been used in a variety of photon and neutron radiation fields, and measured values of dose and dose mean lineal energy are consistent with values extrapolated from measurements made by other techniques at much lower dose rates. It is expected that this technique will prove to be much more reliable than extrapolations from measurements made at low dose rates because these low dose rate exposures generally do not accurately reproduce the attenuation and

  12. High efficiency mixed species radioiodine air sampling, readout, and dose assessment system

    International Nuclear Information System (INIS)

    Distenfeld, C.; Klemish, J.

    1976-05-01

    Reactor accidents require monitoring to assess the impact to persons in the environment. This implies methods and apparatus to accurately and economically sample and evaluate possible released activity. The development of a prototype iodine air sampling system that can differentiate against noble gas activity and be evaluated by standard Civil Defense instrumentation is reported. The apparatus can efficiently (95 percent) collect organic or inorganic, particulate or gaseous radioiodine in concentrations below stable atmospheric iodine, and under severe ambient conditions. Response to noble fission gases was reduced to less than 4 x 10 -4 of an equal iodine airborne activity by heating the collector to approximately 100 0 C. Reliable sample size, +-5 percent, was achieved by using a simple air flow regulator. Thyroid dose commitment was mathematically and graphically related to the iodine isotope distribution expected in the environment and to the response of the Civil Defense CDV-700 instrument used to evaluate the sample. Sensitivity of the method allows dose assessment of 1 to 2 rads to a child's thyroid

  13. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    International Nuclear Information System (INIS)

    Morishima, Hiroshige; Koga, Taeko; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-01-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  14. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    Energy Technology Data Exchange (ETDEWEB)

    Morishima, Hiroshige; Koga, Taeko [Kinki Univ., Higashi-Osaka, Osaka (Japan). Atomic Energy Research Inst.; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-10-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  15. Characteristics of the graded wildlife dose assessment code K-BIOTA and its application

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Kim, Byeong Ho; Choi, Yong Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-12-15

    This paper describes the technical background for the Korean wildlife radiation dose assessment code, K-BIOTA, and the summary of its application. The K-BIOTA applies the graded approaches of 3 levels including the screening assessment (Level 1 and 2), and the detailed assessment based on the site specific data (Level 3). The screening level assessment is a preliminary step to determine whether the detailed assessment is needed, and calculates the dose rate for the grouped organisms, rather than an individual biota. In the Level 1 assessment, the risk quotient (RQ) is calculated by comparing the actual media concentration with the environmental media concentration limit (EMCL) derived from a bench-mark screening reference dose rate. If RQ for the Level 1 assessment is less than 1, it can be determined that the ecosystem would maintain its integrity, and the assessment is terminated. If the RQ is greater than 1, the Level 2 assessment, which calculates RQ using the average value of the concentration ratio (CR) and equilibrium distribution coefficient (Kd) for the grouped organisms, is carried out for the more realistic assessment. Thus, the Level 2 assessment is less conservative than the Level 1 assessment. If RQ for the Level 2 assessment is less than 1, it can be determined that the ecosystem would maintain its integrity, and the assessment is terminated. If the RQ is greater than 1, the Level 3 assessment is performed for the detailed assessment. In the Level 3 assessment, the radiation dose for the representative organism of a site is calculated by using the site specific data of occupancy factor, CR and Kd. In addition, the K-BIOTA allows the uncertainty analysis of the dose rate on CR, Kd and environmental medium concentration among input parameters optionally in the Level 3 assessment. The four probability density functions of normal, lognormal, uniform and exponential distribution can be applied. The applicability of the code was tested through the

  16. Characteristics of the graded wildlife dose assessment code K-BIOTA and its application

    International Nuclear Information System (INIS)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Kim, Byeong Ho; Choi, Yong Ho

    2015-01-01

    This paper describes the technical background for the Korean wildlife radiation dose assessment code, K-BIOTA, and the summary of its application. The K-BIOTA applies the graded approaches of 3 levels including the screening assessment (Level 1 and 2), and the detailed assessment based on the site specific data (Level 3). The screening level assessment is a preliminary step to determine whether the detailed assessment is needed, and calculates the dose rate for the grouped organisms, rather than an individual biota. In the Level 1 assessment, the risk quotient (RQ) is calculated by comparing the actual media concentration with the environmental media concentration limit (EMCL) derived from a bench-mark screening reference dose rate. If RQ for the Level 1 assessment is less than 1, it can be determined that the ecosystem would maintain its integrity, and the assessment is terminated. If the RQ is greater than 1, the Level 2 assessment, which calculates RQ using the average value of the concentration ratio (CR) and equilibrium distribution coefficient (Kd) for the grouped organisms, is carried out for the more realistic assessment. Thus, the Level 2 assessment is less conservative than the Level 1 assessment. If RQ for the Level 2 assessment is less than 1, it can be determined that the ecosystem would maintain its integrity, and the assessment is terminated. If the RQ is greater than 1, the Level 3 assessment is performed for the detailed assessment. In the Level 3 assessment, the radiation dose for the representative organism of a site is calculated by using the site specific data of occupancy factor, CR and Kd. In addition, the K-BIOTA allows the uncertainty analysis of the dose rate on CR, Kd and environmental medium concentration among input parameters optionally in the Level 3 assessment. The four probability density functions of normal, lognormal, uniform and exponential distribution can be applied. The applicability of the code was tested through the

  17. Internal dose assessment in a case of continuous intake of Cs 137

    International Nuclear Information System (INIS)

    Gomez Parada, I.; Rojo, A.M.

    2000-01-01

    In 1997 the Argentine Nuclear Regulatory Authority (ARN) was invited to participate in the '3rd. European Intercomparison Exercise on Internal Dose Assessment'. This paper presents the solution submitted by the ARN to one of the cases proposed in the exercise. This is a real case of continuous ingestion of cesium 137 due to the environmental contamination arising from the Chernobyl accident. The subject was member of the public and the results of whole body counter measurements were provided. The monitoring period spanned from the first month after the accident to approximately 880 days later. The solution implied to estimate the total intake for the accident until the end of the monitoring period, the effective dose received by the subject in 1986 and 1987 respectively and the committed effective dose due to the total intake. For the intake assessment the code Cindy v 1.4 was used, assuming a constant rate of intake during the whole period of intake. The systemic retention model for caesium was that of the ICRP 30, with a modified biological half-life of the long-term retention. The dates of the beginning and end of the period of intake were chosen, using the same software, looking for the ones that fits better to the measurements data. This rate of intake and the same metabolic models used for the intake assessment were the input to the CINDY code to find the dose received by the subject in 1986 and 1987 respectively, as well as the committed effective dose. An alternative dose assessment was made, directly from body burden measurements, in order to compare the obtained values. In this approach, the software Origin 4.0 was used to graph the whole body activity measurements and the integrate it for the desired time intervals. Applying the corresponding Specific Effective Energy value obtained from LUPED 2.06 for the reference man, the effective doses were obtained directly from body burden. It was found that the values for the effective doses were almost the same

  18. A review of the uncertainties in internal radiation dose assessment for inhaled thorium

    International Nuclear Information System (INIS)

    Hewson, G.S.

    1989-01-01

    Present assessments of internal radiation dose to designated radiation workers in the mineral sands industry, calculated using ICRP 26/30 methodology and data, indicate that some workers approach and exceed statutory radiation dose limits. Such exposures are indicative of the need for a critical assessment of work and operational procedures and also of metabolic and dosimetric models used to estimate internal dose. This paper reviews past occupational exposure experience with inhaled thorium compounds, examines uncertainties in the underlying radiation protection models, and indicates the effect of alternative assumptions on the calculation of committed effective dose equivalent. The extremely low recommended inhalation limits for thorium in air do not appear to be well supported by studies on the health status of former thorium refinery workers who were exposed to thorium well in excess of presently accepted limits. The effect of cautious model assumptions is shown to result in internal dose assessments that could be up to an order of magnitude too high. It is concluded that the effect of such uncertainty constrains the usefulness of internal dose estimates as a reliable indicator of actual health risk. 26 refs., 5 figs., 3 tabs

  19. Integrated technique for assessing environmental dose of radioactive waste storage installation

    Energy Technology Data Exchange (ETDEWEB)

    Bor-Jing Chang; Chien-Liang Shih; Ing-Jane Chen [Institute of Nuclear Energy Research, Lungtan, Taiwan (China); Ren-Dih Sheu; Shiang-Huei Jiang [National Tsing Hua University, Hsinchu, Taiwan (China); Shu-Jun Chang [Nuclear Science and Technology Association, Taiwan (China); Ruei-Ying Liao; Pei Yu; Chin-Yi Huang [Taiwan Power Company, Taipei, Taiwan (China)

    2000-05-01

    The ability to accurately predict exposure rates at large distances from a gamma radiation source is becoming increasingly important. This is because that the related regulation for the control of radiation levels in and around nuclear facilities becomes more stringent. Since the continuous increase of the radwaste storage capacity requirement on site, the requirement of a more realistic evaluation is very necessary. Those doses are usually at past time evaluated by QADCG/INER-2 code for direct dose and by SKYSHINE-III code for skyshine dose in which evaluation were over conservatively considered. This study is to update the evaluation code package accompanied with adequate methodology and to establish integrated analysis procedure. Thereafter, radiation doses can be accurately calculated in a reasonably conservative way. The purpose of the investigation is divided into three categories. First, SPECTRUM-506 is used instead of SPECTUM. Nuclide databases are enlarged from 100 up to 506. And the operation is ported to personal computer. Secondly, the QADCG/INER-3 code is developed to enhance the original QADCG/INER-2 code. The most important difference is the use of the geometric progression (GP) fitting function for the gamma-ray buildup factor. SKYSHINE-III code is replaced by McSKY and SKYDOSE codes. They are well benchmarked by using the Monte Carlo code MCNP and sensitive parameters are detailed investigated. Thirdly, the well developed analysis procedure is applicable for nuclear utility radwaste storage sites. Finally, the case studies were performed by using those packages to assess the radiological impact of utility radwaste storage site. The results are verified in detail by using Monte Carlo code MCNP and the results seems pretty consistent from both method. (author)

  20. JADA: a graphical user interface for comprehensive internal dose assessment in nuclear medicine.

    Science.gov (United States)

    Grimes, Joshua; Uribe, Carlos; Celler, Anna

    2013-07-01

    The main objective of this work was to design a comprehensive dosimetry package that would keep all aspects of internal dose calculation within the framework of a single software environment and that would be applicable for a variety of dose calculation approaches. Our MATLAB-based graphical user interface (GUI) can be used for processing data obtained using pure planar, pure SPECT, or hybrid planar/SPECT imaging. Time-activity data for source regions are obtained using a set of tools that allow the user to reconstruct SPECT images, load images, coregister a series of planar images, and to perform two-dimensional and three-dimensional image segmentation. Curve fits are applied to the acquired time-activity data to construct time-activity curves, which are then integrated to obtain time-integrated activity coefficients. Subsequently, dose estimates are made using one of three methods. The organ level dose calculation subGUI calculates mean organ doses that are equivalent to dose assessment performed by OLINDA/EXM. Voxelized dose calculation options, which include the voxel S value approach and Monte Carlo simulation using the EGSnrc user code DOSXYZnrc, are available within the process 3D image data subGUI. The developed internal dosimetry software package provides an assortment of tools for every step in the dose calculation process, eliminating the need for manual data transfer between programs. This saves times and minimizes user errors, while offering a versatility that can be used to efficiently perform patient-specific internal dose calculations in a variety of clinical situations.

  1. ASSESSMENT OF THE AVERAGE ANNUAL EFFECTIVE DOSES FOR THE INHABITANTS OF THE SETTLEMENTS LOCATED IN THE TERRITORIES CONTAMINATED DUE TO THE CHERNOBYL ACCIDENT

    Directory of Open Access Journals (Sweden)

    N. G. Vlasova

    2012-01-01

    Full Text Available Catalogue of the average annual effective exposure doses of the inhabitants of the territories contaminated due to the Chernobul accident had been developed according to the method of the assessment of the average annual effective exposure doses of the settlements inhabitants. The cost-efficacy of the use of the average annual effective dose assessment method was 250 000 USD for the current 5 years. Average annual effective dose exceeded 1 mSv/year for 191 Belarus settlements from 2613. About 50 000 persons are living in these settlements.

  2. Skin dose assessment in routine personnel beta/gamma dosimetry

    International Nuclear Information System (INIS)

    Christensen, P.

    1980-01-01

    Three alternative methods are outlined by which substantial improvements of the capabilities of existing routine monitoring systems for skin dose assessment can be obtained. The introduction of a supplementary skin dosemeter may be an attractive method for systems with badges that have a capability for an additional dosemeter already built-in. The two-side reading method has limited possibilities because of reduced accuracy for mixed radiation and technical difficulties in using it for TLD systems with planchet heating. The use of a boron diffused LiF layer for skin dose assessment seems to be most attractive method since the only modification needed here is replacement of a dosemeter. However the study of this method is so far only in a preliminary stage and further investigations are needed. (U.K.)

  3. Assessment of dose during an SGTR

    International Nuclear Information System (INIS)

    Adams, J.P.

    1993-01-01

    The Nuclear Regulatory Commission requires utilities to determine the response of a pressurized water reactor to a steam generator tube rupture (SGTR) as part of the safety analysis for the plant. The SGTR analysis includes assumptions regarding the iodine concentration in the reactor coolant system (RCS) due to iodine spikes, primary flashing and bypass fractions, and iodine partitioning in the secondary coolant system (SCS). Experimental and analytical investigations have recently been completed wherein these assumptions were tested to determine whether and to what degree they were conservative (that is, whether they result in a calculated iodine source term/dose that is at least as large or larger than that expected during an actual event). The current study has the objective to assess the overall effects of the results of these investigations on the calculated iodine dose to the environment during an SGTR. To assist in this study, a computer program, DOSE, was written. This program uses a simple, non-mechanistic model to calculate the iodine source term to the environment during an SGTR as a function of water mass inventories and flow rates and iodine concentrations in the RCS and SCS. The principal conclusion of this study is that the iodine concentration in the RCS is the dominant parameter, due to the dominance of primary flashing on the iodine source term

  4. Dose-to-man studies

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Dose-to-Man Studies focused on developing computer data handling and computer modules which permit easy, rapid assessment of the dose to southeastern United States populations from routine or accidental releases of radionuclides to atmospheric and stream systems

  5. Assessment of body doses from photon exposures using human voxel models

    International Nuclear Information System (INIS)

    Zankl, M.; Fill, U.; Petoussi-Henss, N.; Regulla, D.

    2000-01-01

    For the scope of risk assessment in protection against ionising radiation (occupational, environmental and medical) it is necessary to determine the radiation dose to specific body organs and tissues. For this purpose, a series of models of the human body were designed in the past, together with computer codes simulating the radiation transport and energy deposition in the body. Most of the computational body models in use are so-called mathematical models; the most famous is the MIRD-5 phantom developed at Oak Ridge National Laboratory. In the 1980s, a new generation of human body models was introduced at GSF, constructed from whole body CT data. Due to being constructed from image data of real persons, these 'voxel models' offer an improved realism of external and internal shape of the body and its organs, compared to MIRD-type models. Comparison of dose calculations involving voxel models with respective dose calculations for MIRD-type models revealed that the deviation of the individual anatomy from that described in the MIRD-type models indeed introduces significant deviations of the calculated organ doses. Specific absorbed fractions of energy released in a source organ due to incorporated activity which are absorbed in target organs may differ by more than an order of magnitude between different body models; for external photon irradiation, the discrepancies are more moderate. (author)

  6. Nuclear plant's virtual simulation for on-line radioactive environment monitoring and dose assessment for personnel

    International Nuclear Information System (INIS)

    Mol, Antonio Carlos A.; Jorge, Carlos Alexandre F.; Lapa, Celso Marcelo F.

    2009-01-01

    This paper reports the use of nuclear plant's simulation for online dose rate monitoring and dose assessment for personnel, using virtual reality technology. The platform used for virtual simulation was adapted from a low cost game engine, taking advantage of all its image rendering capabilities, as well as the physics for movement and collision, and networking capabilities for multi-user interactive navigation. A real nuclear plant was virtually modeled and simulated, so that a number of users can navigate simultaneously in this virtual environment in first or third person view, each one receiving visual information about both the radiation dose rate in each actual position, and the radiation dose received. Currently, this research and development activity has been extended to consider also on-line measurements collected from radiation monitors installed in the real plant that feed the simulation platform with dose rate data, through a TCP/IP network. Results are shown and commented, and other improvements are discussed, as the execution of a more detailed dose rate mapping campaign.

  7. Prospective radiological dose assessment. Amersham plc (Amersham site) variation application December 1998

    International Nuclear Information System (INIS)

    Allott, R.

    2001-01-01

    Amersham plc (previously Nycomed-Amersham plc) submitted an application to the Environment Agency in December 1998 for a variation to their radioactive waste discharge authorisations granted under the Radioactive Substances Act 1993. The application requested a reduction in the discharge limits for certain radionuclides and no change for the remaining radionuclides. Amersham plc undertook a further review of their discharge requirements and submitted a new assessment for revised limits in January 2001. This report provides an assessment of the radiological implications of discharges at these revised limits requested by Amersham plc and the limits proposed by the Agency. It has been prepared by the National Compliance Assessment Service at the request of Thames Region to support their determination of the application. Four candidate critical groups were identified who could be exposed to discharges from the Amersham site: 1) Sewage workers at the Maple Lodge sewage works who might be exposed to external radiation from discharges contained within sewage and inadvertently inhale or ingest sewage. 2) Anglers on the Grand Union Canal who eat a small proportion of their annual catch of freshwater fish, who drink water abstracted solely from the River Colne and eat vegetables irrigated by water from the canal. 3) Persons living closest to site who eat locally produced food. 4) Dog walkers living near to site who eat locally produced food. For continuous discharges at the Agency's proposed annual limits, the highest dose of 160 μSv/y is predicted to be received by infants who live closest to the site and eat locally produced food. Therefore, this has been identified as the critical group. Children and adults living at the same location and eating locally produced food receive doses of 140 μSv/y and 130 μSv/y respectively. The critical group dose is less than the source constraint of 300 μSv/y. The dose is dominated by direct radiation from the site (110 μSv/y) and the

  8. Clinical evaluation of a dose monitoring software tool based on Monte Carlo Simulation in assessment of eye lens doses for cranial CT scans

    Energy Technology Data Exchange (ETDEWEB)

    Guberina, Nika; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Forsting, Michael; Theysohn, Jens; Wetter, Axel; Ringelstein, Adrian [University Hospital Essen, Institute of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany)

    2016-10-15

    The aim of this study was to verify the results of a dose monitoring software tool based on Monte Carlo Simulation (MCS) in assessment of eye lens doses for cranial CT scans. In cooperation with the Federal Office for Radiation Protection (Neuherberg, Germany), phantom measurements were performed with thermoluminescence dosimeters (TLD LiF:Mg,Ti) using cranial CT protocols: (I) CT angiography; (II) unenhanced, cranial CT scans with gantry angulation at a single and (III) without gantry angulation at a dual source CT scanner. Eye lens doses calculated by the dose monitoring tool based on MCS and assessed with TLDs were compared. Eye lens doses are summarized as follows: (I) CT angiography (a) MCS 7 mSv, (b) TLD 5 mSv; (II) unenhanced, cranial CT scan with gantry angulation, (c) MCS 45 mSv, (d) TLD 5 mSv; (III) unenhanced, cranial CT scan without gantry angulation (e) MCS 38 mSv, (f) TLD 35 mSv. Intermodality comparison shows an inaccurate calculation of eye lens doses in unenhanced cranial CT protocols at the single source CT scanner due to the disregard of gantry angulation. On the contrary, the dose monitoring tool showed an accurate calculation of eye lens doses at the dual source CT scanner without gantry angulation and for CT angiography examinations. The dose monitoring software tool based on MCS gave accurate estimates of eye lens doses in cranial CT protocols. However, knowledge of protocol and software specific influences is crucial for correct assessment of eye lens doses in routine clinical use. (orig.)

  9. Clinical evaluation of a dose monitoring software tool based on Monte Carlo Simulation in assessment of eye lens doses for cranial CT scans

    International Nuclear Information System (INIS)

    Guberina, Nika; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Forsting, Michael; Theysohn, Jens; Wetter, Axel; Ringelstein, Adrian

    2016-01-01

    The aim of this study was to verify the results of a dose monitoring software tool based on Monte Carlo Simulation (MCS) in assessment of eye lens doses for cranial CT scans. In cooperation with the Federal Office for Radiation Protection (Neuherberg, Germany), phantom measurements were performed with thermoluminescence dosimeters (TLD LiF:Mg,Ti) using cranial CT protocols: (I) CT angiography; (II) unenhanced, cranial CT scans with gantry angulation at a single and (III) without gantry angulation at a dual source CT scanner. Eye lens doses calculated by the dose monitoring tool based on MCS and assessed with TLDs were compared. Eye lens doses are summarized as follows: (I) CT angiography (a) MCS 7 mSv, (b) TLD 5 mSv; (II) unenhanced, cranial CT scan with gantry angulation, (c) MCS 45 mSv, (d) TLD 5 mSv; (III) unenhanced, cranial CT scan without gantry angulation (e) MCS 38 mSv, (f) TLD 35 mSv. Intermodality comparison shows an inaccurate calculation of eye lens doses in unenhanced cranial CT protocols at the single source CT scanner due to the disregard of gantry angulation. On the contrary, the dose monitoring tool showed an accurate calculation of eye lens doses at the dual source CT scanner without gantry angulation and for CT angiography examinations. The dose monitoring software tool based on MCS gave accurate estimates of eye lens doses in cranial CT protocols. However, knowledge of protocol and software specific influences is crucial for correct assessment of eye lens doses in routine clinical use. (orig.)

  10. Radiation protection cabin for catheter-directed liver interventions: operator dose assessment

    International Nuclear Information System (INIS)

    Maleux, Geert; Bosmans, Hilde; Bergans, Niki; Bogaerts, Ria

    2016-01-01

    The number and complexity of interventional radiological procedures and in particular catheter-directed liver interventions have increased substantially. The current study investigates the reduction of personal doses when using a dedicated radiation protection cabin (RPC) for these procedures. Operator and assistant doses were assessed for 3 series of 20 chemo-infusion/chemoembolisation interventions, including an equal number of procedures with and without RPC. Whole body doses, finger doses and doses at the level of knees and eyes were evaluated with different types of TLD-100 Harshaw dosemeters. Dosemeters were also attached on the three walls of the RPC. The operator doses were significantly reduced by the RPC, but also without RPC, the doses appear to be limited as a result of thorough optimisation with existing radiation protection tools. The added value of the RPC should thus be determined by the outcome of balancing dose reduction and other aspects such as ergonomic benefits. (authors)

  11. Dose. Detriment. Limit assessment; Dosis. Schadensmass. Grenzwertsetzung

    Energy Technology Data Exchange (ETDEWEB)

    Breckow, J. [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz (IMPS)

    2015-07-01

    One goal of radiation protection is the limitation of stochastic effects due to radiation exposure. The probability of occurrence of a radiation induced stochastic effect, however, is only one of several other parameters which determine the radiation detriment. Though the ICRP-concept of detriment is a quantitative definition, the kind of detriment weighting includes somewhat subjective elements. In this sense, the detriment-concept of ICRP represents already at the stage of effective dose a kind of assessment. Thus, by comparing radiation protection standards and concepts interconvertible or with those of environment or occupational protection one should be aware of the possibly different principles of detriment assessment.

  12. ANDROS: A code for Assessment of Nuclide Doses and Risks with Option Selection

    International Nuclear Information System (INIS)

    Begovich, C.L.; Sjoreen, A.L.; Ohr, S.Y.; Chester, R.O.

    1986-11-01

    ANDROS (Assessment of Nuclide Doses and Risks with Option Selection) is a computer code written to compute doses and health effects from atmospheric releases of radionuclides. ANDROS has been designed as an integral part of the CRRIS (Computerized Radiological Risk Investigation System). ANDROS reads air concentrations and environmental concentrations of radionuclides to produce tables of specified doses and health effects to selected organs via selected pathways (e.g., ingestion or air immersion). The calculation may be done for an individual at a specific location or for the population of the whole assessment grid. The user may request tables of specific effects for every assessment grid location. Along with the radionuclide concentrations, the code requires radionuclide decay data, dose and risk factors, and location-specific data, all of which are available within the CRRIS. This document is a user manual for ANDROS and presents the methodology used in this code

  13. SUDOQU, a new dose-assessment methodology for radiological surface contamination.

    Science.gov (United States)

    van Dillen, Teun; van Dijk, Arjan

    2018-06-12

    A new methodology has been developed for the assessment of the annual effective dose resulting from removable and fixed radiological surface contamination. It is entitled SUDOQU (SUrface DOse QUantification) and it can for instance be used to derive criteria for surface contamination related to the import of non-food consumer goods, containers and conveyances, e.g., limiting values and operational screening levels. SUDOQU imposes mass (activity)-balance equations based on radioactive decay, removal and deposition processes in indoor and outdoor environments. This leads to time-dependent contamination levels that may be of particular importance in exposure scenarios dealing with one or a few contaminated items only (usually public exposure scenarios, therefore referred to as the 'consumer' model). Exposure scenarios with a continuous flow of freshly contaminated goods also fall within the scope of the methodology (typically occupational exposure scenarios, thus referred to as the 'worker model'). In this paper we describe SUDOQU, its applications, and its current limitations. First, we delineate the contamination issue, present the assumptions and explain the concepts. We describe the relevant removal, transfer, and deposition processes, and derive equations for the time evolution of the radiological surface-, air- and skin-contamination levels. These are then input for the subsequent evaluation of the annual effective dose with possible contributions from external gamma radiation, inhalation, secondary ingestion (indirect, from hand to mouth), skin contamination, direct ingestion and skin-contact exposure. The limiting effective surface dose is introduced for issues involving the conservatism of dose calculations. SUDOQU can be used by radiation-protection scientists/experts and policy makers in the field of e.g. emergency preparedness, trade and transport, exemption and clearance, waste management, and nuclear facilities. Several practical examples are worked

  14. ACUTRI a computer code for assessing doses to the general public due to acute tritium releases

    CERN Document Server

    Yokoyama, S; Noguchi, H; Ryufuku, S; Sasaki, T

    2002-01-01

    Tritium, which is used as a fuel of a D-T burning fusion reactor, is the most important radionuclide for the safety assessment of a nuclear fusion experimental reactor such as ITER. Thus, a computer code, ACUTRI, which calculates the radiological impact of tritium released accidentally to the atmosphere, has been developed, aiming to be of use in a discussion of licensing of a fusion experimental reactor and an environmental safety evaluation method in Japan. ACUTRI calculates an individual tritium dose based on transfer models specific to tritium in the environment and ICRP dose models. In this calculation it is also possible to analyze statistically on meteorology in the same way as a conventional dose assessment method according to the meteorological guide of the Nuclear Safety Commission of Japan. A Gaussian plume model is used for calculating the atmospheric dispersion of tritium gas (HT) and/or tritiated water (HTO). The environmental pathway model in ACUTRI considers the following internal exposures: i...

  15. Development of Plant Application Technique of Low Dose Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Byung Yeoup; Kim, Jae Sung; Lim, Yong Taek (and others)

    2007-07-15

    The project was carried out to achieve three aims. First, development of application techniques of cell-stimulating effects by low-dose radiation. Following irradiation with gamma-rays of low doses, beneficial effects in crop germination, early growth, and yield were investigated using various plant species and experimental approaches. For the actual field application, corroborative studies were also carried out with a few concerned experimental stations and farmers. Moreover, we attempted to establish a new technique of cell cultivation for industrial mass-production of shikonin, a medicinal compound from Lithospermum erythrorhizon and thereby suggested new application fields for application techniques of low-dose radiation. Second, elucidation of action mechanisms of ionizing radiation in plants. By investigating changes in plant photosynthesis and physiological metabolism, we attempted to elucidate physiological activity-stimulating effects of low-dose radiation and to search for radiation-adaptive cellular components. Besides, analyses of biochemical and molecular biological mechanisms for stimulus-stimulating effects of low-dose radiation were accomplished by examining genes and proteins inducible by low-dose radiation. Third, development of functional crop plants using radiation-resistant factors. Changes in stress-tolerance of plants against environmental stress factors such as light, temperature, salinity and UV-B stress after exposed to low-dose gamma-rays were investigated. Concerned reactive oxygen species, antioxidative enzymes, and antioxidants were also analyzed to develop high value-added and environment-friendly functional plants using radiation-resistant factors. These researches are important to elucidate biological activities increased by low-dose radiation and help to provide leading technologies for improvement of domestic productivity in agriculture and development of high value-added genetic resources.

  16. Development of Plant Application Technique of Low Dose Radiation

    International Nuclear Information System (INIS)

    Chung, Byung Yeoup; Kim, Jae Sung; Lim, Yong Taek

    2007-07-01

    The project was carried out to achieve three aims. First, development of application techniques of cell-stimulating effects by low-dose radiation. Following irradiation with gamma-rays of low doses, beneficial effects in crop germination, early growth, and yield were investigated using various plant species and experimental approaches. For the actual field application, corroborative studies were also carried out with a few concerned experimental stations and farmers. Moreover, we attempted to establish a new technique of cell cultivation for industrial mass-production of shikonin, a medicinal compound from Lithospermum erythrorhizon and thereby suggested new application fields for application techniques of low-dose radiation. Second, elucidation of action mechanisms of ionizing radiation in plants. By investigating changes in plant photosynthesis and physiological metabolism, we attempted to elucidate physiological activity-stimulating effects of low-dose radiation and to search for radiation-adaptive cellular components. Besides, analyses of biochemical and molecular biological mechanisms for stimulus-stimulating effects of low-dose radiation were accomplished by examining genes and proteins inducible by low-dose radiation. Third, development of functional crop plants using radiation-resistant factors. Changes in stress-tolerance of plants against environmental stress factors such as light, temperature, salinity and UV-B stress after exposed to low-dose gamma-rays were investigated. Concerned reactive oxygen species, antioxidative enzymes, and antioxidants were also analyzed to develop high value-added and environment-friendly functional plants using radiation-resistant factors. These researches are important to elucidate biological activities increased by low-dose radiation and help to provide leading technologies for improvement of domestic productivity in agriculture and development of high value-added genetic resources

  17. Biosphere model for assessing doses from nuclear waste disposal

    International Nuclear Information System (INIS)

    Zach, R.; Amiro, B.D.; Davis, P.A.; Sheppard, S.C.; Szekeley, J.G.

    1994-01-01

    The biosphere model, BIOTRAC, for predicting long term nuclide concentrations and radiological doses from Canada's nuclear fuel waste disposal concept of a vault deep in plutonic rock of the Canadian Shield is presented. This generic, boreal zone biosphere model is based on scenario analysis and systems variability analysis using Monte Carlo simulation techniques. Conservatism is used to bridge uncertainties, even though this creates a small amount of extra nuclide mass. Environmental change over the very long assessment period is mainly handled through distributed parameter values. The dose receptors are a critical group of humans and four generic non-human target organisms. BIOTRAC includes six integrated submodels and it interfaces smoothly with a geosphere model. This interface includes a bedrock well. The geosphere model defines the discharge zones of deep groundwater where nuclides released from the vault enter the biosphere occupied by the dose receptors. The size of one of these zones is reduced when water is withdrawn from the bedrock well. Sensitivity analysis indicates 129 I is by far the most important radionuclide. Results also show bedrock-well water leads to higher doses to man than lake water, but the former doses decrease with the size of the critical group. Under comparable circumstances, doses to the non-human biota are greater than those for man

  18. Dose Assessment Model for Chronic Atmospheric Releases of Tritium

    International Nuclear Information System (INIS)

    Shen Huifang; Yao Rentai

    2010-01-01

    An improved dose assessment model for chronic atmospheric releases of tritium was proposed. The proposed model explicitly considered two chemical forms of tritium.It was based on conservative assumption of transfer of tritiated water (HTO) from air to concentration of HTO and organic beam tritium (OBT) in vegetable and animal products.The concentration of tritium in plant products was calculated based on considering dividedly leafy plant and not leafy plant, meanwhile the concentration contribution of tritium in the different plants from the tritium in soil was taken into account.Calculating the concentration of HTO in animal products, average water fraction of animal products and the average weighted tritium concentration of ingested water based on the fraction of water supplied by each source were considered,including skin absorption, inhalation, drinking water and food.Calculating the annual doses, the ingestion doses were considered, at the same time the contribution of inhalation and skin absorption to the dose was considered. Concentrations in foodstuffs and dose of annual adult calculated with the specific activity model, NEWTRI model and the model proposed by the paper were compared. The results indicate that the model proposed by the paper can predict accurately tritium doses through the food chain from chronic atmospheric releases. (authors)

  19. Total dose meter development

    International Nuclear Information System (INIS)

    Brackenbush, L.W.

    1986-09-01

    This report describes an alarming ''pocket'' monitor/dosimeter, based on a tissue-equivalent proportional counter, that measure both neutron and gamma dose and determines dose equivalent for the mixed radiation field. This report details the operation of the device and provides information on: the necessity for a device to measure dose equivalent in mixed radiation fields; the mathematical theory required to determine dose equivalent from tissue equivalent proportional; the detailed electronic circuits required; the algorithms required in the microprocessor used to calculate dose equivalent; the features of the instrument; program accomplishments and future plans

  20. Assessment of dose in cervical vertebrae radiographic examinations

    International Nuclear Information System (INIS)

    Owrnasir, Wafa Fadol Orsud

    2014-12-01

    Reference dose levels provide a framework to reduce doses variability and aid in the optimization of radiation protection.This study was performed in Khartoum Teaching Hospital in period of January to June 2014. This study performed to assess the entrance surface dose ( ESD) received in Cervical Vertebrae radiographic examination and to analyze effective dose distributions among radiological departments under study. The study was performed in Khartoum Teaching Hospital, covering two x-ray units and a sample of 64 patients. The following parameter were recorded; age, weight, height, body mass index (BMI) derived from weight (kg) and height (m) and exposure factors. The dose was measured for Cervical Vertebrae x-ray examinations, the entrance surface dose (ESD) values were estimated from the x-ray tube output parameters for Cervical Vertebrae AP and lateral examinations. The ESD values were then calculated using IAEA calculation methods. The results of ESD values calculated showed than patient exposure were within the normal range of exposure. The mean ED values calculated were ( 3.85 ±0.04) and (4.02 ±0.05) mGy for Cervical Vertebrae AP and lateral examinations, respectively in department Na1 and (3.99± 0.15) and (4.23± 0.34) mGy, for Cervical Vertebrae Ap and lateral examinations respectively in department Na2, the IAEA standard value of ESD for cervical equal (7), (20) mGy AP and LAT, Further studies are recommended with more number of patients and using more than two modalities for comparison. (Author)

  1. Blood compounds irradiation process: assessment of absorbed dose using Fricke and Thermoluminescent dosimetric systems

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Gabriela de Amorim; Squair, Peterson Lima; Pinto, Fausto Carvalho; Belo, Luiz Claudio Meira; Grossi, Pablo Andrade [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN/MG), Belo Horizonte, MG (Brazil)], e-mail: gas@cdtn.br, e-mail: pls@cdtn.br, e-mail: fcp@cdtn.br, e-mail: lcmb@cdtn.br, e-mail: pabloag@cdtn.br

    2009-07-01

    The assessment of gamma absorbed doses in irradiation facilities allows the quality assurance and control of the irradiation process. The liability of dose measurements is assign to the metrological procedures adopted including the uncertainty evaluation. Fricke and TLD 800 dosimetric systems were used to measure absorbed dose in the blood compounds using the methodology presented in this paper. The measured absorbed doses were used for evaluating the effectiveness of the irradiation procedure and the gamma dose absorption inside the irradiation room of a gamma irradiation facility. The radiation eliminates the functional and proliferative capacities of donor T-lymphocytes, preventing Transfusion associated graft-versus-host disease (TA-GVHD), a possible complication of blood transfusions. The results show the applicability of such dosimetric systems in quality assurance programs, assessment of absorbed doses in blood compounds and dose uniformity assign to the blood compounds irradiation process by dose measurements in a range between 25 Gy and 100 Gy. (author)

  2. Blood compounds irradiation process: assessment of absorbed dose using Fricke and Thermoluminescent dosimetric systems

    International Nuclear Information System (INIS)

    Soares, Gabriela de Amorim; Squair, Peterson Lima; Pinto, Fausto Carvalho; Belo, Luiz Claudio Meira; Grossi, Pablo Andrade

    2009-01-01

    The assessment of gamma absorbed doses in irradiation facilities allows the quality assurance and control of the irradiation process. The liability of dose measurements is assign to the metrological procedures adopted including the uncertainty evaluation. Fricke and TLD 800 dosimetric systems were used to measure absorbed dose in the blood compounds using the methodology presented in this paper. The measured absorbed doses were used for evaluating the effectiveness of the irradiation procedure and the gamma dose absorption inside the irradiation room of a gamma irradiation facility. The radiation eliminates the functional and proliferative capacities of donor T-lymphocytes, preventing Transfusion associated graft-versus-host disease (TA-GVHD), a possible complication of blood transfusions. The results show the applicability of such dosimetric systems in quality assurance programs, assessment of absorbed doses in blood compounds and dose uniformity assign to the blood compounds irradiation process by dose measurements in a range between 25 Gy and 100 Gy. (author)

  3. Dose assessment method for control room habitability in accident condition in nuclear power plants

    International Nuclear Information System (INIS)

    Yang Dong; Tang Shaohua; Wang Jianhua

    2012-01-01

    Based on the NRC. technical requirements on NPP control room habitability assessment, and considering the characteristics of the improved second generation NPPs in China, this paper developed a complete dose assessment model for control room habitability. Contrasting to the existing model in China, this model is applicable for DBA and sever accident, and the short term atmospheric diffusion factor can be calculated using the combined wake mode. By considering the zoning of habitable area and the design characteristics of the ventilation system, the effects of un-filtrated air leakage from the building and the ventilation system on the assessment calculation can be considered. (authors)

  4. Occupational dose reduction developments and data collected at nuclear power plants

    International Nuclear Information System (INIS)

    Dionne, B.J.; Baum, J.W.

    1984-01-01

    Occupational dose reduction developments and data collected at nuclear power plants have been described. Written descriptions of repetitive high dose jobs, their collective dose equivalent ranges and list of dose reduction techniques will aid in reducing collective dose equivalents from these dose-reduction targets. Knowing which components contribute to high maintenance or repair dose will aid in reducing routine maintenance collective dose equivalents. The radwaste dose reduction improvements will aid in reducing radwaste operations collective dose equivalent and reduce the number of radwaste workers who exceed their administrative dose limits. The identification and rating of managers' and workers' ALARA incentives will provide the basis for recommendations to improve dose reduction incentives. Lastly, the identification and rating of the key components of an ALARA program will aid in the development and coordination of the nuclear station ALARA programs

  5. Risk and dose assessment methods in gamma knife QA

    International Nuclear Information System (INIS)

    Banks, W.W.; Jones, E.D.; Rathbun, P.

    1992-10-01

    Traditional methods used in assessing risk in nuclear power plants may be inappropriate to use in assessing medical radiation risks. The typical philosophy used in assessing nuclear reactor risks is machine dominated with only secondary attention paid to the human component, and only after critical machine failure events have been identified. In assessing the risk of a misadministrative radiation dose to patients, the primary source of failures seems to stem overwhelmingly, from the actions of people and only secondarily from machine mode failures. In essence, certain medical misadministrations are dominated by human events not machine failures. Radiological medical devices such as the Leksell Gamma Knife are very simple in design, have few moving parts, and are relatively free from the risks of wear when compared with a nuclear power plant. Since there are major technical differences between a gamma knife and a nuclear power plant, one must select a particular risk assessment method which is sensitive to these system differences and tailored to the unique medical aspects of the phenomena under study. These differences also generate major shifts in the philosophy and assumptions which drive the risk assessment (Machine-centered vs Person-centered) method. We were prompted by these basic differences to develop a person-centered approach to risk assessment which would reflect these basic philosophical and technological differences, have the necessary resolution in its metrics, and be highly reliable (repeatable). The risk approach chosen by the Livermore investigative team has been called the ''Relative Risk Profile Method'' and has been described in detail by Banks and Paramore, (1983)

  6. Public Dose Assessment Modeling from Skyshine by Proton Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Mwambinga, S. A. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Yoo, S. J. [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2013-10-15

    In this paper, the skyshine dose by proton accelerator (230 MeV) has been evaluated. The amount of dose by skyshine is related to some influence factors which are emission angle (Height wall), the thickness of ceiling and distance from source to receptor (Human body). Empirical formula is made by using MCNPX code results. It can easily calculate and assess dose from skyshine by proton accelerator. The skyshine doses are calculated with MCNPX code and DCFs in ICRP 116. Thereafter, we made empirical formula which can calculate dose easily and be compared with the results of MCNPX. The maximum exposure point by skyshine is about 5 ∼ 10 m from source. Therefore, the licensee who wants to operate the proton accelerator must keep the appropriate distance from accelerator and set the fence to restrict the approach by the public. And, exposure doses by accelerator depend on operating time and proton beam intensities. Eq. (6) suggested in this study is just considered for mono energy proton accelerator. Therefore, it is necessary to expand the dose calculation to diverse proton energies. Radiations like neutron and photon generated by high energy proton accelerators over 10 MeV, are important exposure sources to be monitored to radiation workers and the public members near the facility. At that case, one of the exposure pathways to the public who are located in near the facility is skyshine. Neutrons and photons can be scattered by the atmosphere near the facility and exposed to public as scattered dose. All of the facilities using high energy radiation and NDI (Non-Destructive Inspection) which is tested at open field, skyshine dose must be taken into consideration. Skyshine dose is not related to the wall thickness of radiation shielding directly.

  7. A Review of Models for Dose Assessment Employed by SKB in the Renewed Safety Assessment for SFR 1

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, George [Imperial College of Science Technology and Medicine (United Kingdom)

    2002-09-01

    This document provides a critical review, on behalf of SSI, of the models employed by the Swedish Nuclear Fuel and Waste Management Co (SKB) for dose assessment in the renewed safety assessment for the final repository for radioactive operational waste (SFR 1) in Forsmark, Sweden. The main objective of the review is to examine the models used by SKB for radiological dose assessment in a series of evolving biotopes in the vicinity of the Forsmark repository within a time frame beginning in 3000 AD and extending beyond 7500 AD. Five biosphere models (for coasts, lakes, agriculture, mires and wells) are described in Report TR-01-04. The principal consideration of the review is to determine whether these models are fit for the purpose of dose evaluation over the time frames involved and in the evolving sequence of biotopes specified. As well as providing general observations and comments on the modelling approach taken, six specific questions are addressed, as follows. Are the assumptions underlying the models justifiable? Are all reasonably foreseeable environmental processes considered? Has parameter uncertainty been sufficiently and reasonably addressed? Have sufficient models been used to address all reasonably foreseeable biotopes? Are the transitions between biotopes modelled adequately (specifically, are initial conditions for developing biotopes adequately specified by calculations for subsiding biotopes)? Have all critical radionuclides been identified? It is concluded that, in general, the assumptions underlying most of the models are justifiable. The exceptions are a) the rather simplistic approach taken in the Coastal Model and b) the lack of consideration of wild foods and age-dependence when calculating exposures of humans to radionuclides via dietary pathways. Most foreseeable processes appear to have been accounted for within the constraints of the models used, although it is recommended that attention be paid to future climate states when considering

  8. Accurate assessment of the distortions produced by the transit dose in HDR brachytherapy

    International Nuclear Information System (INIS)

    Nani, E.K.; Kyere, A.W.K.; Tetteh, K.

    2001-01-01

    Current polynomial methods used in the modelling of the dose distributions in HDR brachytherapy have been reformulated to improve accuracy. An example is provided to show the effects of the transit dose on the output. The transit dose, which is neglected by current computer software for calculating doses, can result in significant dosimetric errors. These additional unrecognised doses imply over-dosing and distortions in the dose distributions within the irradiated volume. Assessment of dose to critical and radiosensitive organs is therefore inaccurate. These could increase late tissue complications as predicted by the Linear Quadratic Model. Our model works very well for straight catheters and is highly recommended for the evaluation of the transit dose around such catheters. (author)

  9. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  10. Occupational radiation dose assessment for a non site specific spent fuel storage facility

    International Nuclear Information System (INIS)

    Hadley, J.; Eble, R.G. Jr.

    1997-01-01

    To expedite the licensing process of the non site specific Centralized Interim Storage Facility (CISF) the Department of Energy has completed a phase I CISF Topical Safety Analysis Report (TSAR). The TSAR will be used in licensing the phase I CISF if a site is designated. An occupational radiation does assessment of the facility operations is performed as part of the phase I CISF design. The first phase of the CISF has the capability to receive, transfer, and store SNF in dual-purpose cask/canister systems (DPC's). Currently there are five vendor technologies under consideration. The preliminary dose assessment is based on estimated occupational exposures using traditional power plant ISFSI and transport cask handling processes. The second step in the process is to recommend ALARA techniques to reduce potential exposures. A final dose assessment is completed implementing the ALARA techniques and a review is performed to ensure that the design is in compliance with regulatory criteria. The dose assessment and ALARA evaluation are determined using the following input information: Dose estimates from vendor SAR's; ISFSI experience with similar systems; Traditional methods of operations; Expected CISF cask receipt rates; and feasible ALARA techniques. 5 refs., 1 tab

  11. Computer program for assessing the human dose due to stationary release of tritium

    International Nuclear Information System (INIS)

    Saito, Masahiro; Raskob, Wolfgang

    2003-01-01

    The computer program TriStat (Tritium dose assessment for stationary release) has been developed to assess the dose to humans assuming a stationary release of tritium as HTO and/or HT from nuclear facilities. A Gaussian dispersion model describes the behavior of HT gas and HTO vapor in the atmosphere. Tritium concentrations in soil, vegetables and forage were estimated on the basis of specific tritium concentrations in the free water component and the organic component. The uptake of contamination via food by humans was modeled by assuming a forage compartment, a vegetable component, and an animal compartment. A standardized vegetable and a standardized animal with the relative content of major nutrients, i.e. proteins, lipids and carbohydrates, representing a standard Japanese diet, were included. A standardized forage was defined in a similar manner by using the forage composition for typical farm animals. These standard feed- and foodstuffs are useful to simplify the tritium dosimetry and the food chain related to the tritium transfer to the human body. (author)

  12. Methods of assessment of individual and collective doses to transport workers and members of the public during the transport of radioactive material

    International Nuclear Information System (INIS)

    Vohra, K.G.; Subrahmanian, G.; Nandakumar, A.N.; Kher, R.K.; Iyer, S.R.K.

    1986-01-01

    Transport workers handling radioactive cargoes are generally exposed to the highest dose rates of any population group. Methods of assessment of dose received by transport workers are studied to arrive at a useful method. An empirical model based on a detailed work study of individuals handling radioactive cargoes and the exposure rates at various distances from specific individual packages is developed. The personnel doses thus calculated compared reasonably well with the doses recorded on personnel monitoring badges. The personnel doses were also evaluated with reference to the total transport index handled by the workers, yielding results consistent with those reported elsewhere by earlier researchers. For assessing the collective dose to the public due to urban transport of radioactive material, the space around the vehicle transporting cargo was divided into a number of cells of dimensions 1mx1m. The radiation level in each cell was measured and the pedestrian density along the route was obtained. Using the pedestrian occupancy in the cells and the measured radiation levels, the total dose to the public was assessed. A similar assessment was made with respect to the passengers in the neighbouring vehicles. The suggested method of calculation may aid determination of the route and time of transport and the preferable traffic configuration for the vehicle carrying the radioactive consignments for optimizing the dose to the urban public

  13. Development of a Radiation Dose Reporting Software for X-ray Computed Tomography (CT)

    Science.gov (United States)

    Ding, Aiping

    software provides a better CT dose assessment by using anatomically realistic patient phantoms. All the related organ doses are incorporated into a standardized database compiled using Microsoft Structured Query Language (SQL) server 2008. Organ doses from contiguous axial or helical scans defined by a specific protocol can be rapidly obtained from the database. A next-generation software architecture and Active Server Pages (ASP) .NET framework are adopted to create a browser-hosted application to improve the user interactivity and reporting functionality including scanning parameter selection and organ dose reporting. “VirtualDose” has been developed as a web-based CT dose reporting platform to facilitate several important features including: (1) easy access via Internet; (2) no need for installation on the local computer; (3) a user-friendly, dynamic, browser-hosted graphical user interface; (4) use of advanced patient models for the adult male and female, pregnant women, children, and obese patient models; (5) adoption of modern CT scanners and protocols, as well as the most recent ICRP 103 effective dose algorithms; and (6) flexibility to manage and easily upgrade without impacting user’s usage.

  14. Developing RESRAD-BASELINE for environmental baseline risk assessment

    International Nuclear Information System (INIS)

    Cheng, Jing-Jy.

    1995-01-01

    RESRAD-BASELINE is a computer code developed at Argonne developed at Argonne National Laboratory for the US Department of Energy (DOE) to perform both radiological and chemical risk assessments. The code implements the baseline risk assessment guidance of the US Environmental Protection Agency (EPA 1989). The computer code calculates (1) radiation doses and cancer risks from exposure to radioactive materials, and (2) hazard indexes and cancer risks from exposure to noncarcinogenic and carcinogenic chemicals, respectively. The user can enter measured or predicted environmental media concentrations from the graphic interface and can simulate different exposure scenarios by selecting the appropriate pathways and modifying the exposure parameters. The database used by PESRAD-BASELINE includes dose conversion factors and slope factors for radionuclides and toxicity information and properties for chemicals. The user can modify the database for use in the calculation. Sensitivity analysis can be performed while running the computer code to examine the influence of the input parameters. Use of RESRAD-BASELINE for risk analysis is easy, fast, and cost-saving. Furthermore, it ensures in consistency in methodology for both radiological and chemical risk analyses

  15. Development of double dosimetry algorithm for assessment of effective dose to staff in interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Young

    2011-02-15

    Medical staff involving interventional radiology(IR) procedures are significantly exposed to the scatter radiation because they stand in close proximity to the patient. Since modern IR techniques are often very complicated and require extended operation time, doses to IR workers tend to increase considerably. In general, the personal dose equivalent at 10 mm depth, H{sub p}(10), read from one dosimeter worn on the trunk of a radiation worker is assumed to be a good estimate of the effective dose and compared to the dose limits for regulatory compliance. This assumption is based on the exposure conditions that the radiation field is broad and rather homogeneous. However, IR workers usually wear protective clothing like lead aprons and thyroid shield which allow part of the body being exposed to much higher doses. To solve this problem, i.e. to adequately estimate the effective doses of IR workers, use of double dosimeters, one under the apron and one over the apron where unshielded part of the body exposed, was recommended. Several algorithms on the interpretation of the two dosimeter readings have been proposed. However, the dosimeter weighting factors applied to the algorithm differ significantly, which quests a question on the reliability of the algorithm. Moreover, there are some changes in the process of calculating the effective dose in the 2007 recommendations of the International Commission on Radiological Protection(ICRP): changes in the radiation weighting factors, tissue weighting factors and the computational reference phantoms. Therefore, this study attempts to set a new algorithm for interpreting two dosimeter readings to provide a proper estimate of the effective dose for IR workers, incorporating those changes in definition of effective dose. The effective doses were estimated using Monte Carlo simulations for various practical conditions based on the vogel reference phantom and the new tissue weighting factors. A quasi-effective dose, which is

  16. Development of double dosimetry algorithm for assessment of effective dose to staff in interventional radiology

    International Nuclear Information System (INIS)

    Kim, Ji Young

    2011-02-01

    Medical staff involving interventional radiology(IR) procedures are significantly exposed to the scatter radiation because they stand in close proximity to the patient. Since modern IR techniques are often very complicated and require extended operation time, doses to IR workers tend to increase considerably. In general, the personal dose equivalent at 10 mm depth, H p (10), read from one dosimeter worn on the trunk of a radiation worker is assumed to be a good estimate of the effective dose and compared to the dose limits for regulatory compliance. This assumption is based on the exposure conditions that the radiation field is broad and rather homogeneous. However, IR workers usually wear protective clothing like lead aprons and thyroid shield which allow part of the body being exposed to much higher doses. To solve this problem, i.e. to adequately estimate the effective doses of IR workers, use of double dosimeters, one under the apron and one over the apron where unshielded part of the body exposed, was recommended. Several algorithms on the interpretation of the two dosimeter readings have been proposed. However, the dosimeter weighting factors applied to the algorithm differ significantly, which quests a question on the reliability of the algorithm. Moreover, there are some changes in the process of calculating the effective dose in the 2007 recommendations of the International Commission on Radiological Protection(ICRP): changes in the radiation weighting factors, tissue weighting factors and the computational reference phantoms. Therefore, this study attempts to set a new algorithm for interpreting two dosimeter readings to provide a proper estimate of the effective dose for IR workers, incorporating those changes in definition of effective dose. The effective doses were estimated using Monte Carlo simulations for various practical conditions based on the vogel reference phantom and the new tissue weighting factors. A quasi-effective dose, which is

  17. Models for dose assessments. Modules for various biosphere types

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, U.; Nordlinder, S.; Aggeryd, I. [Studsvik Eco and Safety AB, Nykoeping (Sweden)

    1999-12-01

    The main objective of this study was to provide a basis for illustrations of yearly dose rates to the most exposed individual from hypothetical leakages of radionuclides from a deep bedrock repository for spent nuclear fuel and other radioactive waste. The results of this study will be used in the safety assessment SR 97 and in a study on the design and long-term safety for a repository planned to contain long-lived low and intermediate level waste. The repositories will be designed to isolate the radionuclides for several hundred thousands of years. In the SR 97 study, however, hypothetical scenarios for leakage are postulated. Radionuclides are hence assumed to be transported in the geosphere by groundwater, and probably discharge into the biosphere. This may occur in several types of ecosystems. A number of categories of such ecosystems were identified, and turnover of radionuclides was modelled separately for each ecosystem. Previous studies had focused on generic models for wells, lakes and coastal areas. These models were, in this study, developed further to use site-specific data. In addition, flows of groundwater, containing radionuclides, to agricultural land and peat bogs were considered. All these categories are referred to as modules in this report. The forest ecosystems were not included, due to a general lack of knowledge of biospheric processes in connection with discharge of groundwater in forested areas. Examples of each type of module were run with the assumption of a continuous annual release into the biosphere of 1 Bq for each radionuclide during 10 000 years. The results are presented as ecosystem specific dose conversion factors (EDFs) for each nuclide at the year 10 000, assuming stationary ecosystems and prevailing living conditions and habits. All calculations were performed with uncertainty analyses included. Simplifications and assumptions in the modelling of biospheric processes are discussed. The use of modules may be seen as a step

  18. Models for dose assessments. Modules for various biosphere types

    International Nuclear Information System (INIS)

    Bergstroem, U.; Nordlinder, S.; Aggeryd, I.

    1999-12-01

    The main objective of this study was to provide a basis for illustrations of yearly dose rates to the most exposed individual from hypothetical leakages of radionuclides from a deep bedrock repository for spent nuclear fuel and other radioactive waste. The results of this study will be used in the safety assessment SR 97 and in a study on the design and long-term safety for a repository planned to contain long-lived low and intermediate level waste. The repositories will be designed to isolate the radionuclides for several hundred thousands of years. In the SR 97 study, however, hypothetical scenarios for leakage are postulated. Radionuclides are hence assumed to be transported in the geosphere by groundwater, and probably discharge into the biosphere. This may occur in several types of ecosystems. A number of categories of such ecosystems were identified, and turnover of radionuclides was modelled separately for each ecosystem. Previous studies had focused on generic models for wells, lakes and coastal areas. These models were, in this study, developed further to use site-specific data. In addition, flows of groundwater, containing radionuclides, to agricultural land and peat bogs were considered. All these categories are referred to as modules in this report. The forest ecosystems were not included, due to a general lack of knowledge of biospheric processes in connection with discharge of groundwater in forested areas. Examples of each type of module were run with the assumption of a continuous annual release into the biosphere of 1 Bq for each radionuclide during 10 000 years. The results are presented as ecosystem specific dose conversion factors (EDFs) for each nuclide at the year 10 000, assuming stationary ecosystems and prevailing living conditions and habits. All calculations were performed with uncertainty analyses included. Simplifications and assumptions in the modelling of biospheric processes are discussed. The use of modules may be seen as a step

  19. Assessment of doses due to secondary neutrons received by patient treated by proton therapy

    International Nuclear Information System (INIS)

    Sayah, R.; Martinetti, F.; Donadille, L.; Clairand, I.; Delacroix, S.; De Oliveira, A.; Herault, J.

    2010-01-01

    Proton therapy is a specific technique of radiotherapy which aims at destroying cancerous cells by irradiating them with a proton beam. Nuclear reactions in the device and in the patient himself induce secondary radiations involving mainly neutrons which contribute to an additional dose for the patient. The author reports a study aimed at the assessment of these doses due to secondary neutrons in the case of ophthalmological and intra-cranial treatments. He presents a Monte Carlo simulation of the room and of the apparatus, reports the experimental validation of the model (dose deposited by protons in a water phantom, ambient dose equivalent due to neutrons in the treatment room, absorbed dose due to secondary particles in an anthropomorphic phantom), and the assessment with a mathematical phantom of doses dues to secondary neutrons received by organs during an ophthalmological treatment. He finally evokes current works of calculation of doses due to secondary neutrons in the case of intra-cranial treatments

  20. Determination of Entrance Skin Doses and Organ Doses for Medical X Ray Examinations

    International Nuclear Information System (INIS)

    Tung, C.J.; Cheng, C.Y.; Chao, T.C.; Tsai, H.Y.

    1999-01-01

    A national survey of patient doses for diagnostic X ray radiographs is planned in Taiwan. Entrance skin doses and organ doses for all installed X ray machines will be investigated. A pilot study has been carried out for the national survey to develop a protocol for the dose assessment. Entrance skin doses and organ doses were measured by thermoluminescence dosemeters and calculated by Monte Carlo simulations for several X ray examinations. The conversion factor from free air entrance absorbed dose to entrance skin dose was derived. A formula for the computation of entrance skin doses from inputs of kV p , mA.s, source to skin distance, aluminium filtration, and generator rectifying was constructed. Organ doses were measured using a RANDO phantom and calculated using a mathematical phantom. All data will be passed to the Atomic Energy Council for developing a programme of national survey and regulatory controls for diagnostic X ray examinations. (author)

  1. Dose volume assessment of high dose rate 192IR endobronchial implants

    International Nuclear Information System (INIS)

    Cheng, B. Saw; Korb, Leroy J.; Pawlicki, Todd; Wu, Andrew

    1996-01-01

    Purpose: To study the dose distributions of high dose rate (HDR) endobronchial implants using the dose nonuniformity ratio (DNR) and three volumetric irradiation indices. Methods and Materials: Multiple implants were configured by allowing a single HDR 192 Ir source to step through a length of 6 cm along an endobronchial catheter. Dwell times were computed to deliver a dose of 5 Gy to points 1 cm away from the catheter axis. Five sets of source configurations, each with different dwell position spacings from 0.5 to 3.0 cm, were evaluated. Three-dimensional (3D) dose distributions were then generated for each source configuration. Differential and cumulative dose-volume curves were generated to quantify the degree of target volume coverage, dose nonuniformity within the target volume, and irradiation of tissues outside the target volume. Evaluation of the implants were made using the DNR and three volumetric irradiation indices. Results: The observed isodose distributions were not able to satisfy all the dose constraints. The ability to optimally satisfy the dose constraints depended on the choice of dwell position spacing and the specification of the dose constraint points. The DNR and irradiation indices suggest that small dwell position spacing does not result in a more homogeneous dose distribution for the implant. This study supports the existence of a relationship between the dwell position spacing and the distance from the catheter axis to the reference dose or dose constraint points. Better dose homogeneity for an implant can be obtained if the spacing of the dwell positions are about twice the distance from the catheter axis to the reference dose or dose constraint points

  2. Specific gamma-ray dose constants for nuclides important to dosimetry and radiological assessment

    International Nuclear Information System (INIS)

    Unger, L.M.; Trubey, D.K.

    1982-05-01

    Tables of specific gamma-ray dose constants (the unshielded gamma-ray dose equivalent rate at 1 m from a point source) have been computed for approximately 500 nuclides important to dosimetry and radiological assessment. The half life, the mean attenuation coefficient, and thickness for a lead shield providing 95% dose equivalent attenuation are also listed

  3. Prescribing and evaluating target dose in dose-painting treatment plans

    DEFF Research Database (Denmark)

    Håkansson, Katrin; Specht, Lena; Aznar, Marianne C

    2014-01-01

    BACKGROUND: Assessment of target dose conformity in multi-dose-level treatment plans is challenging due to inevitable over/underdosage at the border zone between dose levels. Here, we evaluate different target dose prescription planning aims and approaches to evaluate the relative merit of such p......-painting and multi-dose-level plans. The tool can be useful for quality assurance of multi-center trials, and for visualizing the development of treatment planning in routine clinical practice....... of such plans. A quality volume histogram (QVH) tool for history-based evaluation is proposed. MATERIAL AND METHODS: Twenty head and neck cancer dose-painting plans with five prescription levels were evaluated, as well as clinically delivered simultaneous integrated boost (SIB) plans from 2010 and 2012. The QVH...

  4. Personalized Assessment of kV Cone Beam Computed Tomography Doses in Image-guided Radiotherapy of Pediatric Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Yibao [Beijing Key Lab of Medical Physics and Engineering, Peking University, Beijing (China); Yan Yulong [Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, Arkansas (United States); Nath, Ravinder [Department of Therapeutic Radiology, Yale University, New Haven, Connecticut (United States); Bao Shanglian [Beijing Key Lab of Medical Physics and Engineering, Peking University, Beijing (China); Deng Jun, E-mail: jun.deng@yale.edu [Department of Therapeutic Radiology, Yale University, New Haven, Connecticut (United States)

    2012-08-01

    Purpose: To develop a quantitative method for the estimation of kV cone beam computed tomography (kVCBCT) doses in pediatric patients undergoing image-guided radiotherapy. Methods and Materials: Forty-two children were retrospectively analyzed in subgroups of different scanned regions: one group in the head-and-neck and the other group in the pelvis. Critical structures in planning CT images were delineated on an Eclipse treatment planning system before being converted into CT phantoms for Monte Carlo simulations. A benchmarked EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions of kVCBCT scans with full-fan high-quality head or half-fan pelvis protocols predefined by the manufacturer. Based on planning CT images and structures exported in DICOM RT format, occipital-frontal circumferences (OFC) were calculated for head-and-neck patients using DICOMan software. Similarly, hip circumferences (HIP) were acquired for the pelvic group. Correlations between mean organ doses and age, weight, OFC, and HIP values were analyzed with SigmaPlot software suite, where regression performances were analyzed with relative dose differences (RDD) and coefficients of determination (R{sup 2}). Results: kVCBCT-contributed mean doses to all critical structures decreased monotonically with studied parameters, with a steeper decrease in the pelvis than in the head. Empirical functions have been developed for a dose estimation of the major organs at risk in the head and pelvis, respectively. If evaluated with physical parameters other than age, a mean RDD of up to 7.9% was observed for all the structures in our population of 42 patients. Conclusions: kVCBCT doses are highly correlated with patient size. According to this study, weight can be used as a primary index for dose assessment in both head and pelvis scans, while OFC and HIP may serve as secondary indices for dose estimation in corresponding regions. With the proposed empirical functions, it is possible

  5. Methods of assessing total doses integrated across pathways

    International Nuclear Information System (INIS)

    Grzechnik, M.; Camplin, W.; Clyne, F.; Allott, R.; Webbe-Wood, D.

    2006-01-01

    Calculated doses for comparison with limits resulting from discharges into the environment should be summed across all relevant pathways and food groups to ensure adequate protection. Current methodology for assessments used in the radioactivity in Food and the Environment (R.I.F.E.) reports separate doses from pathways related to liquid discharges of radioactivity to the environment from those due to gaseous releases. Surveys of local inhabitant food consumption and occupancy rates are conducted in the vicinity of nuclear sites. Information has been recorded in an integrated way, such that the data for each individual is recorded for all pathways of interest. These can include consumption of foods, such as fish, crustaceans, molluscs, fruit and vegetables, milk and meats. Occupancy times over beach sediments and time spent in close proximity to the site is also recorded for inclusion of external and inhalation radiation dose pathways. The integrated habits survey data may be combined with monitored environmental radionuclide concentrations to calculate total dose. The criteria for successful adoption of a method for this calculation were: Reproducibility can others easily use the approach and reassess doses? Rigour and realism how good is the match with reality?Transparency a measure of the ease with which others can understand how the calculations are performed and what they mean. Homogeneity is the group receiving the dose relatively homogeneous with respect to age, diet and those aspects that affect the dose received? Five methods of total dose calculation were compared and ranked according to their suitability. Each method was labelled (A to E) and given a short, relevant name for identification. The methods are described below; A) Individual doses to individuals are calculated and critical group selection is dependent on dose received. B) Individual Plus As in A, but consumption and occupancy rates for high dose is used to derive rates for application in

  6. Multiple methods for assessing the dose to skin exposed to radioactive contamination

    International Nuclear Information System (INIS)

    Dubeau, J.; Heinmiller, B.E.; Corrigan, M.

    2017-01-01

    There is the possibility for a worker at a nuclear installation, such as a nuclear power reactor, a fuel production facility or a medical facility, to come in contact with radioactive contaminants. When such an event occurs, the first order of business is to care for the worker by promptly initiating a decontamination process. Usually, the radiation protection personnel performs a G-M pancake probe measurement of the contamination in situ and collects part or all of the radioactive contamination for further laboratory analysis. The health physicist on duty must then perform, using the available information, a skin dose assessment that will go into the worker's permanent dose record. The contamination situations are often complex and the dose assessment can be laborious. This article compares five dose assessment methods that involve analysis, new technologies and new software. The five methods are applied to 13 actual contamination incidents consisting of direct skin contact, contamination on clothing and contamination on clothing in the presence of an air gap between the clothing and the skin. This work shows that, for the cases studied, the methods provided dose estimates that were usually within 12% (1σ) of each other, for those cases where absolute activity information for every radionuclide was available. One method, which relies simply on a G-M pancake probe measurement, appeared to be particularly useful in situations where a contamination sample could not be recovered for laboratory analysis. (authors)

  7. Integrated Worker Radiation Dose Assessment for the K Basins

    International Nuclear Information System (INIS)

    NELSON, J.V.

    1999-01-01

    This report documents an assessment of the radiation dose workers at the K Basins are expected to receive in the process of removing spent nuclear fuel from the storage basins. The K Basins (K East and K West) are located in the Hanford 100K Area

  8. Ocular organ dose assessment of nuclear medicine workers handling diagnostic radionuclides

    International Nuclear Information System (INIS)

    Cho, Yong In; Kim, Ja Mee; Kim, Jung Hoon

    2017-01-01

    The dose distribution in the ocular organs of nuclear medicine workers during the handling of diagnostic radionuclides was assessed via simulation in virtual space. The cornea and lenses received the highest dose, and the dose distribution tended to be proportional to the gamma-ray energy emitted from the radiation source being handled. Moreover, calculations on the dose-reduction effects of eye-wear protectors for the eyes of the workers showed that the effects were inversely proportional to the emitted gamma-ray energy, with the dose-reduction effect decreasing in the order of "2"0"1Tl, "1"2"3I, "9"9mTc, "6"7Ga, "1"1"1In and "1"8F. Among the considered sources, the dose-reduction effect was significant for sources that emit relatively less energy, namely "1"2"3I, "2"0"1Tl and "9"9mTc, while it was lower for the remaining sources, namely "1"8F, "1"1"1In and "6"7Ga. (authors)

  9. Radiation dose assessment in nuclear plants through virtual simulations using a game engine

    International Nuclear Information System (INIS)

    Jorge, Carlos A.F.; Mol, Antonio C. A.; Aghina, Mauricio Alves C.

    2008-01-01

    Full text: This paper reports an R and D which has the purpose of performing dose assessment of workers in nuclear plants, through virtual simulations using a game engine. The main objective of this R and D is to support the planning of operational and maintenance routines in nuclear plants, aiming to reduce the dose received by workers. Game engine is the core of a computer game, that is usually made independent of both the scenarios and the original applications, and thus can be adapted for any other purposes, including scientific or technological ones. Computer games have experienced a great development in the last years, regarding computer graphics, 3D image rendering and the representation of the physics needed for the virtual simulations, such as gravity effect and collision among virtual components within the games. Thus, researchers do not need to develop an entire platform for virtual simulations, what would be a hard work itself, but they can rather take advantage of such well developed platforms, adapting them for their own applications. The game engine used in this R and D is part of a computer game widely used, Unreal, that has its source code partially open, and can be pursued for low cost. A nuclear plant in our Institution, Argonauta research reactor, has been virtually modeled in 3D, and trainees can navigate virtually through it, with realistic walking velocity, and experiencing collision. The modified game engine computes and displays in real-time the dose received by a virtual person, the avatar, as it walks through the plant, from the radiation dose rate distribution assigned to the virtual environment. In the beginning of this R and D, radiation dose rate measurements were previously collected by the radiological protection service, and input off-line to the game engine. Currently, on-line measurements can be also input to it, by taking advantage of the game's networking capabilities. A real radiation monitor has been used to collect real

  10. Personnel neutron dose assessment upgrade: Volume 2, Field neutron spectrometer for health physics applications

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Reece, W.D.; Miller, S.D.

    1988-07-01

    Both the (ICRP) and the (NCPR) have recommended an increase in neutron quality factors and the adoption of effective dose equivalent methods. The series of reports entitled Personnel Neutron Dose Assessment Upgrade (PNL-6620) addresses these changes. Volume 1 in this series of reports (Personnel Neutron Dosimetry Assessment) provided guidance on the characteristics, use, and calibration of personnel neutron dosimeters in order to meet the new recommendations. This report, Volume 2: Field Neutron Spectrometer for Health Physics Applications describes the development of a portable field spectrometer which can be set up for use in a few minutes by a single person. The field spectrometer described herein represents a significant advance in improving the accuracy of neutron dose assessment. It permits an immediate analysis of the energy spectral distribution associated with the radiation from which neutron quality factor can be determined. It is now possible to depart from the use of maximum Q by determining and realistically applying a lower Q based on spectral data. The field spectrometer is made up of two modules: a detector module with built-in electronics and an analysis module with a IBM PC/reg sign/-compatible computer to control the data acquisition and analysis of data in the field. The unit is simple enough to allow the operator to perform spectral measurements with minimal training. The instrument is intended for use in steady-state radiation fields with neutrons energies covering the fission spectrum range. The prototype field spectrometer has been field tested in plutonium processing facilities, and has been proven to operate satisfactorily. The prototype field spectrometer uses a 3 He proportional counter to measure the neutron energy spectrum between 50 keV and 5 MeV and a tissue equivalent proportional counter (TEPC) to measure absorbed neutron dose

  11. Dose delivery verification and accuracy assessment of stereotaxy in stereotactic radiotherapy and radiosurgery

    International Nuclear Information System (INIS)

    Pelagade, S.M.; Bopche, T.T.; Namitha, K.; Munshi, M.; Bhola, S.; Sharma, H.; Patel, B.K.; Vyas, R.K.

    2008-01-01

    The outcome of stereotactic radiotherapy (SRT) and stereotactic radiosurgery (SRS) in both benign and malignant tumors within the cranial region highly depends on precision in dosimetry, dose delivery and the accuracy assessment of stereotaxy associated with the unit. The frames BRW (Brown-Roberts-Wells) and GTC (Gill- Thomas-Cosman) can facilitate accurate patient positioning as well as precise targeting of tumours. The implementation of this technique may result in a significant benefit as compared to conventional therapy. As the target localization accuracy is improved, the demand for treatment planning accuracy of a TPS is also increased. The accuracy of stereotactic X Knife treatment planning system has two components to verify: (i) the dose delivery verification and the accuracy assessment of stereotaxy; (ii) to ensure that the Cartesian coordinate system associated is well established within the TPS for accurate determination of a target position. Both dose delivery verification and target positional accuracy affect dose delivery accuracy to a defined target. Hence there is a need to verify these two components in quality assurance protocol. The main intention of this paper is to present our dose delivery verification procedure using cylindrical wax phantom and accuracy assessment (target position) of stereotaxy using Geometric Phantom on Elekta's Precise linear accelerator for stereotactic installation

  12. Assessment of patient doses and image quality in X-ray diagnostics in Norway

    International Nuclear Information System (INIS)

    Olerud, H.M.

    1998-01-01

    Results from other industrialized countries indicate that the annual number of diagnostic procedures approaches one for every member of the population, and in many cases the individual radiation doses are higher than from any other human activity. Furthermore, the doses to patients for the same type of examination differ widely from place to place, suggesting that there is a considerable potential for dose reduction. This motivated an investigation of the diagnostic use of X-rays in Norway. The trends in the number of X-ray examinations performed annually have been studied. The patient doses (all diagnostics) and image quality (mammography and computed tomography) have been assessed for various radiological procedures. This form the basis for the assessment of total collective effective dose (CED) from X-rays in Norway, and further risk estimates. The radiological practice has then been evaluated according to the radiation protection principles of justification and optimisation. Based on the 1993 examination frequency, the total CED was assessed to 3400 manSv (0.78 mSv/inhabitant). It is estimated that this radiation burden may cause about 100 excess cancer deaths annually. The frequency of CT examination has doubled every fifth year, and did in 1993 represent 7% of the total number of examinations and 30% of the total CED. 129 refs

  13. Assessment of patient doses and image quality in X-ray diagnostics in Norway

    Energy Technology Data Exchange (ETDEWEB)

    Olerud, H M

    1998-06-01

    Results from other industrialized countries indicate that the annual number of diagnostic procedures approaches one for every member of the population, and in many cases the individual radiation doses are higher than from any other human activity. Furthermore, the doses to patients for the same type of examination differ widely from place to place, suggesting that there is a considerable potential for dose reduction. This motivated an investigation of the diagnostic use of X-rays in Norway. The trends in the number of X-ray examinations performed annually have been studied. The patient doses (all diagnostics) and image quality (mammography and computed tomography) have been assessed for various radiological procedures. This form the basis for the assessment of total collective effective dose (CED) from X-rays in Norway, and further risk estimates. The radiological practice has then been evaluated according to the radiation protection principles of justification and optimisation. Based on the 1993 examination frequency, the total CED was assessed to 3400 manSv (0.78 mSv/inhabitant). It is estimated that this radiation burden may cause about 100 excess cancer deaths annually. The frequency of CT examination has doubled every fifth year, and did in 1993 represent 7% of the total number of examinations and 30% of the total CED. 129 refs.

  14. Development of a method to estimate organ doses for pediatric CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Papadakis, Antonios E., E-mail: apapadak@pagni.gr; Perisinakis, Kostas; Damilakis, John [Department of Medical Physics, University Hospital of Heraklion, Faculty of Medicine, University of Crete, P.O. Box 1352, Iraklion, Crete 71110 (Greece)

    2016-05-15

    Purpose: To develop a method for estimating doses to primarily exposed organs in pediatric CT by taking into account patient size and automatic tube current modulation (ATCM). Methods: A Monte Carlo CT dosimetry software package, which creates patient-specific voxelized phantoms, accurately simulates CT exposures, and generates dose images depicting the energy imparted on the exposed volume, was used. Routine head, thorax, and abdomen/pelvis CT examinations in 92 pediatric patients, ranging from 1-month to 14-yr-old (49 boys and 43 girls), were simulated on a 64-slice CT scanner. Two sets of simulations were performed in each patient using (i) a fixed tube current (FTC) value over the entire examination length and (ii) the ATCM profile extracted from the DICOM header of the reconstructed images. Normalized to CTDI{sub vol} organ dose was derived for all primary irradiated radiosensitive organs. Normalized dose data were correlated to patient’s water equivalent diameter using log-transformed linear regression analysis. Results: The maximum percent difference in normalized organ dose between FTC and ATCM acquisitions was 10% for eyes in head, 26% for thymus in thorax, and 76% for kidneys in abdomen/pelvis. In most of the organs, the correlation between dose and water equivalent diameter was significantly improved in ATCM compared to FTC acquisitions (P < 0.001). Conclusions: The proposed method employs size specific CTDI{sub vol}-normalized organ dose coefficients for ATCM-activated and FTC acquisitions in pediatric CT. These coefficients are substantially different between ATCM and FTC modes of operation and enable a more accurate assessment of patient-specific organ dose in the clinical setting.

  15. Equine scintigraphy: assessment of the dose received by the personnel

    International Nuclear Information System (INIS)

    Clairand, I.; Bottollier, J.F.; Trompier, F.

    2003-01-01

    Following a request from the Permanent Secretary of the French Commission for Artificial Radioelements (CIREA) engaged to investigate a request for a licence related to a new scintigraphy unit dedicated to equidae, a dosimetric assessment concerning the personnel attending the examination was carried out. This scintigraphy unit depends on the Goustranville Centre for Imaging and Research on the Locomotive Diseases of Equidae (CIRALE) in the Calvados region. The dosimetric assessment was carried out for the different operators during the successive stages of the scintigraphic examination. Assuming 150 examinations per year, the annual equivalent dose to the fingers skin is 150 mSv maximum for the technologist and 2 mSv for the veterinary surgeon; the annual effective dose ranges from 0.15 to 0.45 mSv, depending on the operators. (authors)

  16. Measurement and assessment of doses from external radiations required for revised radiation protection regulations

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Norio; Kojima, Noboru; Hayashi, Naomi [Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan)

    2001-06-01

    Radiation protection regulations based on the 1990 recommendations of ICRP have been revised and will take effect from Apr., 2001. The major changes concerning on the measurement and assessment of doses from external radiations are as follows. (1) Personal dose equivalent and ambient dose equivalent stated in ICRP Publication 74 are introduced as quantities to be measured with personal dosimeters and survey instruments, respectively. (2) For multiple dosimetry for workers, the compartment weighting factors used for a realistic assessment of effective dose are markedly changed. In advance of the introduction of the new radiation protection regulations, the impacts on workplace and personal monitoring for external radiations by these revisions were investigated. The following results were obtained. (1) A new ambient dose equivalent to neutrons is higher with a factor of 1.2 than the old one for moderated fission neutron spectra. Therefore, neutron dose equivalent monitors for workplace monitoring at MOX fuel for facilities should be recalibrated for measurement of the new ambient dose equivalent. (2) Annual effective doses of workers were estimated by applying new calibration factors to readings of personal dosimeters, worn by workers. Differences between effective doses and effective dose equivalents are small for workers engaged in the fabrication process of MOX fuel. (author)

  17. Measurement and assessment of doses from external radiations required for revised radiation protection regulations

    International Nuclear Information System (INIS)

    Tsujimura, Norio; Kojima, Noboru; Hayashi, Naomi

    2001-01-01

    Radiation protection regulations based on the 1990 recommendations of ICRP have been revised and will take effect from Apr., 2001. The major changes concerning on the measurement and assessment of doses from external radiations are as follows. (1) Personal dose equivalent and ambient dose equivalent stated in ICRP Publication 74 are introduced as quantities to be measured with personal dosimeters and survey instruments, respectively. (2) For multiple dosimetry for workers, the compartment weighting factors used for a realistic assessment of effective dose are markedly changed. In advance of the introduction of the new radiation protection regulations, the impacts on workplace and personal monitoring for external radiations by these revisions were investigated. The following results were obtained. (1) A new ambient dose equivalent to neutrons is higher with a factor of 1.2 than the old one for moderated fission neutron spectra. Therefore, neutron dose equivalent monitors for workplace monitoring at MOX fuel for facilities should be recalibrated for measurement of the new ambient dose equivalent. (2) Annual effective doses of workers were estimated by applying new calibration factors to readings of personal dosimeters, worn by workers. Differences between effective doses and effective dose equivalents are small for workers engaged in the fabrication process of MOX fuel. (author)

  18. Irrigation in dose assessments models

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Ulla; Barkefors, Catarina [Studsvik RadWaste AB, Nykoeping (Sweden)

    2004-05-01

    SKB has carried out several safety analyses for repositories for radioactive waste, one of which was SR 97, a multi-site study concerned with a future deep bedrock repository for high-level waste. In case of future releases due to unforeseen failure of the protective multiple barrier system, radionuclides may be transported with groundwater and may reach the biosphere. Assessments of doses have to be carried out with a long-term perspective. Specific models are therefore employed to estimate consequences to man. It has been determined that the main pathway for nuclides from groundwater or surface water to soil is via irrigation. Irrigation may cause contamination of crops directly by e.g. interception or rain-splash, and indirectly via root-uptake from contaminated soil. The exposed people are in many safety assessments assumed to be self-sufficient, i.e. their food is produced locally where the concentration of radionuclides may be the highest. Irrigation therefore plays an important role when estimating consequences. The present study is therefore concerned with a more extensive analysis of the role of irrigation for possible future doses to people living in the area surrounding a repository. Current irrigation practices in Sweden are summarised, showing that vegetables and potatoes are the most common crops for irrigation. In general, however, irrigation is not so common in Sweden. The irrigation model used in the latest assessments is described. A sensitivity analysis is performed showing that, as expected, interception of irrigation water and retention on vegetation surfaces are important parameters. The parameters used to describe this are discussed. A summary is also given how irrigation is proposed to be handled in the international BIOMASS (BIOsphere Modelling and ASSessment) project and in models like TAME and BIOTRAC. Similarities and differences are pointed out. Some numerical results are presented showing that surface contamination in general gives the

  19. Irrigation in dose assessments models

    International Nuclear Information System (INIS)

    Bergstroem, Ulla; Barkefors, Catarina

    2004-05-01

    SKB has carried out several safety analyses for repositories for radioactive waste, one of which was SR 97, a multi-site study concerned with a future deep bedrock repository for high-level waste. In case of future releases due to unforeseen failure of the protective multiple barrier system, radionuclides may be transported with groundwater and may reach the biosphere. Assessments of doses have to be carried out with a long-term perspective. Specific models are therefore employed to estimate consequences to man. It has been determined that the main pathway for nuclides from groundwater or surface water to soil is via irrigation. Irrigation may cause contamination of crops directly by e.g. interception or rain-splash, and indirectly via root-uptake from contaminated soil. The exposed people are in many safety assessments assumed to be self-sufficient, i.e. their food is produced locally where the concentration of radionuclides may be the highest. Irrigation therefore plays an important role when estimating consequences. The present study is therefore concerned with a more extensive analysis of the role of irrigation for possible future doses to people living in the area surrounding a repository. Current irrigation practices in Sweden are summarised, showing that vegetables and potatoes are the most common crops for irrigation. In general, however, irrigation is not so common in Sweden. The irrigation model used in the latest assessments is described. A sensitivity analysis is performed showing that, as expected, interception of irrigation water and retention on vegetation surfaces are important parameters. The parameters used to describe this are discussed. A summary is also given how irrigation is proposed to be handled in the international BIOMASS (BIOsphere Modelling and ASSessment) project and in models like TAME and BIOTRAC. Similarities and differences are pointed out. Some numerical results are presented showing that surface contamination in general gives the

  20. Dose assessment at Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Phillips, W.A.; Colsher, C.S.

    1977-01-01

    Bikini Atoll is one of two sites in the northern Marshall Islands that was used by the United States as testing grounds for the nuclear weapons program from 1946 to 1958. In 1969 a general cleanup began at Bikini Atoll. Subsistence crops, coconut and Pandanus fruit, were planted on Bikini and Eneu Islands, and housing was constructed on Bikini Island. A second phase of housing was planned for the interior of Bikini Island. Preliminary data indicated that external gamma doses in the interior of the island might be higher than in other parts of the island. Therefore, to select a second site for housing on the island with minimum external exposure, a survey of Bikini Atoll was conducted in June 1975. External gamma measurements were made on Bikini and Eneu Islands, and soil and vegetations samples collected to evaluate the potential doses via terrestrial food chains and inhalation. Estimates of potential dose via the marine food chain were based upon data collected on previous trips to the atoll. The terrestrial pathway contributes the greater percentage, external gamma exposure contributes the next highest, and inhalation and marine pathways contribute minor fractions of the total whole body and bone marrow doses. The radionuclides contributing the major fraction of the dose are 90 Sr and 137 Cs. All living patterns involving Bikini Island exceed federal guidelines for 30-yr population doses. The Eneu Island living pattern leads to doses that are slightly less than federal guidelines. All patterns evaluated for Bikini Atoll lead to higher doses than those on the southern islands at Enewetak Atoll

  1. Monitoring requirements for assessment of internal dose

    International Nuclear Information System (INIS)

    Eckerman, K.F.

    1985-01-01

    Data obtained by routine personnel monitoring is usually not a sufficient basis for estimation of dose. Collected data must be interpreted carefully and supplemented with appropriate information before reasonably accurate estimates of dose (i.e., accurate enough to indicate whether or nor personnel are exposed in excess of recommended limits) can be developed. When the exposure is of sufficient magnitude that a rather precise estimate of dose is needed, the health physicist will bring to bear on the problem other, more refined, methods of dosimetry. These might include a reconstruction of the incident and, for internal emitters, an extensive series of in vivo measurements or analyses of excreta. Thus, cases of special significance must often be evaluated using techniques and resources beyond those routinely employed. This is not a criticism of most routine monitoring programs. These programs are usually carefully designed in a manner commensurate with the degree of exposure routinely encountered and the requirement of a practical program of radiation protection. 10 refs

  2. The assessment of the collective dose for China population travelling by water

    International Nuclear Information System (INIS)

    Yue Qingyu; Jiang Ping; Jin Hua

    1992-01-01

    The exposure dose rate at 212 points in six shipping lines of the inshore and inland rivers has been measured and the average natural sources exposure dose rate which may be received by the travellers in each shipping line has got. The assessment of collective dose equivalent for the travellers on the shipping lines and the fishery people on the sea has done. In 1988, the collective dose equivalent from natural sources received by Chinese population travelled on the shipping lines of the inshore and inland rivers was 32.7 man·Sv, and the collective dose equivalent from natural sources received by fishery people on the sea was 265.3 man·Sv. The average dose equivalent rate from natural sources at various stayed point received by people of China is given

  3. A novel approach to pharmacodynamic assessment of antimicrobial agents: new insights to dosing regimen design.

    Directory of Open Access Journals (Sweden)

    Vincent H Tam

    Full Text Available Pharmacodynamic modeling has been increasingly used as a decision support tool to guide dosing regimen selection, both in the drug development and clinical settings. Killing by antimicrobial agents has been traditionally classified categorically as concentration-dependent (which would favor less fractionating regimens or time-dependent (for which more frequent dosing is preferred. While intuitive and useful to explain empiric data, a more informative approach is necessary to provide a robust assessment of pharmacodynamic profiles in situations other than the extremes of the spectrum (e.g., agents which exhibit partial concentration-dependent killing. A quantitative approach to describe the interaction of an antimicrobial agent and a pathogen is proposed to fill this unmet need. A hypothetic antimicrobial agent with linear pharmacokinetics is used for illustrative purposes. A non-linear functional form (sigmoid Emax of killing consisted of 3 parameters is used. Using different parameter values in conjunction with the relative growth rate of the pathogen and antimicrobial agent concentration ranges, various conventional pharmacodynamic surrogate indices (e.g., AUC/MIC, Cmax/MIC, %T>MIC could be satisfactorily linked to outcomes. In addition, the dosing intensity represented by the average kill rate of a dosing regimen can be derived, which could be used for quantitative comparison. The relevance of our approach is further supported by experimental data from our previous investigations using a variety of gram-negative bacteria and antimicrobial agents (moxifloxacin, levofloxacin, gentamicin, amikacin and meropenem. The pharmacodynamic profiles of a wide range of antimicrobial agents can be assessed by a more flexible computational tool to support dosing selection.

  4. Post-closure radiation dose assessment for Yucca Mountain repository

    International Nuclear Information System (INIS)

    Jia Mingyan; Zhang Xiabin; Yang Chuncai

    2006-01-01

    A brief introduction of post-closure long-term radiation safety assessment results was represented for the yucca mountain high-level waste geographic disposal repository. In 1 million years after repository closure, for the higher temperature repository operating mode, the peak annual dose would be 150 millirem (120 millirem under the lower-temperature operating mode) to a reasonably maximally exposed individual approximately 18 kilometers (11 miles) from the repository. The analysis of a drilling intrusion event occurring at 30,000 years indicated a peak of the mean annual dose to the reasonably maximally exposed individual approximately 18 kilometers (11 miles) downstream of the repository would be 0.002 millirem. The analysis of an igneous activity scenario, including a volcanic eruption event and igneous intrusion event indicated a peak of the mean annual dose to the reasonably maximally exposed individual approximately 18 kilometers downstream of the repository would be 0.1 millirem. (authors)

  5. Assessment of cosmic radiation doses received by air crew

    International Nuclear Information System (INIS)

    McAulay, I.R.

    1998-01-01

    Cosmic radiation in the atmosphere is such a complex mixture of radiation type that it is difficult to get a single instrument which is suitable for such measurements. Passive devices such as film badges and track etch detectors have also been used, but again present difficulties of interpretation and requirements of multiple devices to accommodate the different types of radiation encountered. In summary, air crew are the occupational group most highly exposed to radiation. The radiation doses experienced by them are sufficiently high as to require assessment on a regular basis and possible control by appropriate rostering. There appears little possibility of the dose limit for workers being exceeded, except possibly in the case of pregnant female crew. This category of air crew should be the subject of special controls aimed at ensuring that the dose limits for the foetus should not be exceeded

  6. Radiation therapy for stage IIA and IIB testicular seminoma: peripheral dose calculations and risk assessments

    Science.gov (United States)

    Mazonakis, Michalis; Berris, Theocharris; Lyraraki, Efrossyni; Damilakis, John

    2015-03-01

    This study was conducted to calculate the peripheral dose to critical structures and assess the radiation risks from modern radiotherapy for stage IIA/IIB testicular seminoma. A Monte Carlo code was used for treatment simulation on a computational phantom representing an average adult. The initial treatment phase involved anteroposterior and posteroanaterior modified dog-leg fields exposing para-aortic and ipsilateral iliac lymph nodes followed by a cone-down phase for nodal mass irradiation. Peripheral doses were calculated using different modified dog-leg field dimensions and an extended conventional dog-leg portal. The risk models of the BEIR-VII report and ICRP-103 were combined with dosimetric calculations to estimate the probability of developing stochastic effects. Radiotherapy for stage IIA seminoma with a target dose of 30 Gy resulted in a range of 23.0-603.7 mGy to non-targeted peripheral tissues and organs. The corresponding range for treatment of stage IIB disease to a cumulative dose of 36 Gy was 24.2-633.9 mGy. A dose variation of less than 13% was found by altering the field dimensions. Radiotherapy with the conventional instead of the modern modified dog-leg field increased the peripheral dose up to 8.2 times. The calculated heart doses of 589.0-632.9 mGy may increase the risk for developing cardiovascular diseases whereas the testicular dose of more than 231.9 mGy may lead to a temporary infertility. The probability of birth abnormalities in the offspring of cancer survivors was below 0.13% which is much lower than the spontaneous mutation rate. Abdominoplevic irradiation may increase the lifetime intrinsic risk for the induction of secondary malignancies by 0.6-3.9% depending upon the site of interest, patient’s age and tumor dose. Radiotherapy for stage IIA/IIB seminoma with restricted fields and low doses is associated with an increased morbidity. These data may allow the definition of a risk-adapted follow-up scheme for long

  7. Use of electron paramagnetic resonance dosimetry with tooth enamel for retrospective dose assessment. Report of a co-ordinated research project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-12-01

    Electron paramagnetic resonance (EPR) dosimetry is a physical method for the assessment of absorbed dose from ionising radiation. It is based on the measurement of stable radiation induced radicals in human calcified tissues (primarily in tooth enamel). EPR dosimetry with teeth is now firmly established in retrospective dosimetry. It is a powerful method for providing information on exposure to ionising radiation many years after the event, since the 'signal' is 'stored' in the tooth or the bone. This technique is of particular relevance to relatively low dose exposures or when the results of conventional dosimetry are not available (e.g. in accidental circumstances). The use of EPR dosimetry, as an essential tool for retrospective assessment of radiation exposure is an important part of radioepidemiological studies and also provides data to select appropriate countermeasures based on retrospective evaluation of individual doses. Despite well established regulations and protocols for maintaining radiation protection dose limits, the assurance that these limits will not be exceeded cannot be guaranteed, thus providing new challenges for development of accurate methods of individual dose assessment. To meet some of these challenges, in 1998 the IAEA initiated a co-ordinated research project (CRP) with the objective to review the available methods, current research and development in EPR biodosimetry technology, which may be of practical use. The major goal of this CRP was to investigate the use of EPR biodosimetry for reconstruction of absorbed dose in tooth enamel with the aim of providing Member States with up-to-date, and generally agreed upon advice regarding the most suitable procedures and the best focus for their research. The co-ordinated research project was conducted over four years and this publication presents the results and findings by a group of investigators from different countries. The available cytogenetic methods for radiation dose assessment were

  8. Use of electron paramagnetic resonance dosimetry with tooth enamel for retrospective dose assessment. Report of a co-ordinated research project

    International Nuclear Information System (INIS)

    2002-12-01

    Electron paramagnetic resonance (EPR) dosimetry is a physical method for the assessment of absorbed dose from ionising radiation. It is based on the measurement of stable radiation induced radicals in human calcified tissues (primarily in tooth enamel). EPR dosimetry with teeth is now firmly established in retrospective dosimetry. It is a powerful method for providing information on exposure to ionising radiation many years after the event, since the 'signal' is 'stored' in the tooth or the bone. This technique is of particular relevance to relatively low dose exposures or when the results of conventional dosimetry are not available (e.g. in accidental circumstances). The use of EPR dosimetry, as an essential tool for retrospective assessment of radiation exposure is an important part of radioepidemiological studies and also provides data to select appropriate countermeasures based on retrospective evaluation of individual doses. Despite well established regulations and protocols for maintaining radiation protection dose limits, the assurance that these limits will not be exceeded cannot be guaranteed, thus providing new challenges for development of accurate methods of individual dose assessment. To meet some of these challenges, in 1998 the IAEA initiated a co-ordinated research project (CRP) with the objective to review the available methods, current research and development in EPR biodosimetry technology, which may be of practical use. The major goal of this CRP was to investigate the use of EPR biodosimetry for reconstruction of absorbed dose in tooth enamel with the aim of providing Member States with up-to-date, and generally agreed upon advice regarding the most suitable procedures and the best focus for their research. The co-ordinated research project was conducted over four years and this publication presents the results and findings by a group of investigators from different countries. The available cytogenetic methods for radiation dose assessment were

  9. Identification and dose assessment of irradiated cardamom and cloves by EPR spectrometry

    International Nuclear Information System (INIS)

    Beshir, W.B.

    2014-01-01

    The use of electron paramagnetic resonance spectroscopy to accurately distinguish irradiated from unirradiated cardamom and cloves and assesses the absorbed dose to radiation processed cardamom and cloves are examined. The results were successful for identifying both irradiated and unirradiated cardamom and cloves. Additive reirradiation of cardamom and cloves produces reproducible dose–response functions, which can be used to assess the initial dose by back-extrapolation. Third degree polynomial function was used to fit the EPR signal/dose curves. It was found that this 3rd degree polynomial function provides satisfactory results without correction of decay for free radicals. The stability of the radiation induced EPR signal of irradiated cardamom and cloves were studied over a storage period of almost 8 months. The calculated G-value (The number of radicals per 100 eV of absorbed energy) for cardamom and cloves was found 0.07±0.01 and 0.055±0.01, respectively. - Highlights: • The EPR analysis of cardamom and cloves prove the sample has been irradiated or not. • Dose additive can be used for evaluation of the absorbed dose in cardamom and cloves. • The 3rd polynomial function can be used to fit the data and the estimated dose. • The stability of the radiation induced EPR signal of irradiated cardamom and cloves were studied over 2 months

  10. The Radiobiological Basis for Improvements in Radiotherapy and Low Dose Risk Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Hei, Tom K. [Columbia Univ., New York, NY (United States)

    2009-12-09

    This conference grant was proposed to organize and host an international conference at Columbia University in New York to critically assess the cellular and molecular signaling events and tissue response following radiation damage. The conference would also serve as a venue to play tribute to the more than forty years contributions made by Professor Eric J. Hall to the radiation biology field. The goals of the meeting were to examine tumor hypoxia and sensitizer development; recent advances made in clinical radiotherapy; addressed several low dose phenomena, including genomic instability and bystander effects that are important in radiation risk assessment. Study and Results: The symposium was held on October 13th and 14th, 2008 at the Alfred Lerner Hall in the Morningside campus of Columbia University. The symposium, entitled “From Beans to Genes: A Forty Year Odyssey in Radiation Biology” was attended by more than 120 faculty, scientists, clinicians, fellows and students. The symposium, spanned over a day and a half, covered four scientific themes. These included tumor hypoxia and radiosensitizers; low dose radiation response; radiation biology in the practice of radiotherapy, and radiation hazard in space and genetic predisposition to cancer. The program of the symposium is as follow:

  11. EPA's Benchmark Dose Modeling Software

    Science.gov (United States)

    The EPA developed the Benchmark Dose Software (BMDS) as a tool to help Agency risk assessors facilitate applying benchmark dose (BMD) method’s to EPA’s human health risk assessment (HHRA) documents. The application of BMD methods overcomes many well know limitations ...

  12. EcoDoses improving radiological assessment of doses to man from terrestrial ecosystems. A status report for the NKS-B project 2003

    Energy Technology Data Exchange (ETDEWEB)

    Bergan, T. [Lavrans Skuterud, Haevard Thoerring (Norway); Liland, A. [Norwegian Radiation Protection Authority (NRPA) (Denmark)] (eds.)

    2004-05-01

    The NKS B-programme EcoDoses project started in 2003 as a collaboration between all the Nordic countries. The aim of the project is to improve the radiological assessments of doses to man from terrestrial ecosystems. The first part, conducted in 2003, has focussed on an extensive collation and review of both published and unpublished data from all the Nordic countries for the nuclear weapons fallout period and the post-Chemobyl period. This included data on radionuclides in air filters, precipitation, soil samples, milk and reindeer. Based on this, an improved model for estimating radioactive fallout based on precipitation data during the nuclear weapons fallout period has been developed. Effective ecological half- lives for 137Cs and 90Sr in milk have been calculated for the nuclear weapons fallout period. For reindeer the ecological half- lives for 137Cs have been calculated for both the nuclear weapons fallout period and the post-Chemobyl period. The data were also used to compare modelling results with observed concentrations. This was done at a workshop where the radioecological food-and-dose module in the ARGOS decision support system was used to predict transfer of deposited radionuclides to foodstuffs and subsequent radiation doses to man. The work conducted the first year is presented in this report and gives interesting, new results relevant for terrestrial radioecology. (au)

  13. A study on mice exposure dose for low-dose gamma-irradiation using glass dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Sung Jin; Kim, Hyo Jin; Kim, Hyun; Jeong, Dong Hyeok; Son, Tae Gen; Kim, Jung Ki; Yang, Kwang Mo; Kang, Yeong Rok [Research Center, Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of); Nam, Sang Hee [Dept. of Biomedical Engineering, Inje University, Gimhae (Korea, Republic of)

    2015-12-15

    The low dose radiation is done for a long period, thus researchers have to know the exact dose distribution for the irradiated mouse. This research has been conducted in order to find out methods in transmitting an exact dose to mouse in a mouse irradiation experiment carried out using {sup 137}C{sub s} irradiation equipment installed in the DIRAMS (Dongnam Institution of Radiological and Medical Sciences) research center. We developed a single mouse housing cage and shelf with adjustable geometric factors such as distance and angle from collimator. The measurement of irradiated dose showed a maximal 42% difference of absorbed dose from the desired dose in the conventional irradiation system, whereas only 6% difference of the absorbed dose was measured in the self-developed mouse apartment system. In addition, multi mice housing showed much difference of the absorbed dose in between head and body, compared to single mouse housing in the conventional irradiation system. This research may allow further research about biological effect assessment for the low dose irradiation using the self-developed mouse apartment to provide more exact doses which it tries to transmit, and to have more reliability for the biological analysis results.

  14. Radiation dose assessment of ACP hot cell in accident

    International Nuclear Information System (INIS)

    Kook, D. H.; Jeong, W. M.; Koo, J. H.; Jeo, I. J.; Lee, E. P.; Ryu, K. S.

    2003-01-01

    The Advanced spent fuel Condition in Process(ACP) is under development for the effective management of spent fuel which had been generated in nuclear plants. The ACP needs a hot cell where most operations will be performed. To give priority to the environments safety, radiation doses evaluations for the radioactive nuclides in accident cases were preliminarily performed with the meteorological data around facility site. Fire accident prevails over several accidnets. Internal Dose and External Dose evaluation according to short dispersion data for that case show a safe margin for regulation limits and SAR limit of IMEF where this facility will be constructed

  15. Dental radiography: tooth enamel EPR dose assessment from Rando phantom measurements

    International Nuclear Information System (INIS)

    Aragno, D.; Fattibene, P.; Onori, S.

    2000-01-01

    Electron paramagnetic resonance dosimetry of tooth enamel is now established as a suitable method for individual dose reconstruction following radiation accidents. The accuracy of the method is limited by some confounding factors, among which is the dose received due to medical x-ray irradiation. In the present paper the EPR response of tooth enamel to endoral examination was experimentally evaluated using an anthropomorphic phantom. The dose to enamel for a single exposure of a typical dental examination performed with a new x-ray generation unit working at 65 kVp gave rise to a CO 2 -signal of intensity similar to that induced by a dose of about 2 mGy of 60 Co. EPR measurements were performed on the entire tooth with no attempt to separate buccal and lingual components. Also the dose to enamel for an orthopantomography exam was estimated. It was derived from TLD measurements as equivalent to 0.2 mGy of 60 Co. In view of application to risk assessment analysis, in the present work the value for the ratio of the reference dose at the phantom surface measured with TLD to the dose at the tooth measured with EPR was determined. (author)

  16. Algorithm for assessment of mean annual gonad dose and genetically significant dose from the data of personal dosimetry

    International Nuclear Information System (INIS)

    Tomasevic, M.; Radovanovic, R.

    1986-01-01

    During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author)

  17. Wound trauma alters ionizing radiation dose assessment

    Directory of Open Access Journals (Sweden)

    Kiang Juliann G

    2012-06-01

    Full Text Available Abstract Background Wounding following whole-body γ-irradiation (radiation combined injury, RCI increases mortality. Wounding-induced increases in radiation mortality are triggered by sustained activation of inducible nitric oxide synthase pathways, persistent alteration of cytokine homeostasis, and increased susceptibility to bacterial infection. Among these factors, cytokines along with other biomarkers have been adopted for biodosimetric evaluation and assessment of radiation dose and injury. Therefore, wounding could complicate biodosimetric assessments. Results In this report, such confounding effects were addressed. Mice were given 60Co γ-photon radiation followed by skin wounding. Wound trauma exacerbated radiation-induced mortality, body-weight loss, and wound healing. Analyses of DNA damage in bone-marrow cells and peripheral blood mononuclear cells (PBMCs, changes in hematology and cytokine profiles, and fundamental clinical signs were evaluated. Early biomarkers (1 d after RCI vs. irradiation alone included significant decreases in survivin expression in bone marrow cells, enhanced increases in γ-H2AX formation in Lin+ bone marrow cells, enhanced increases in IL-1β, IL-6, IL-8, and G-CSF concentrations in blood, and concomitant decreases in γ-H2AX formation in PBMCs and decreases in numbers of splenocytes, lymphocytes, and neutrophils. Intermediate biomarkers (7 – 10 d after RCI included continuously decreased γ-H2AX formation in PBMC and enhanced increases in IL-1β, IL-6, IL-8, and G-CSF concentrations in blood. The clinical signs evaluated after RCI were increased water consumption, decreased body weight, and decreased wound healing rate and survival rate. Late clinical signs (30 d after RCI included poor survival and wound healing. Conclusion Results suggest that confounding factors such as wounding alters ionizing radiation dose assessment and agents inhibiting these responses may prove therapeutic for radiation combined

  18. QUANTITATION OF MOLECULAR ENDPOINTS FOR THE DOSE-RESPONSE COMPONENT OF CANCER RISK ASSESSMENT

    Science.gov (United States)

    Cancer risk assessment involves the steps of hazard identification, dose-response assessment, exposure assessment and risk characterization. The rapid advances in the use of molecular biology approaches has had an impact on all four components, but the greatest overall current...

  19. Realistic retrospective dose assessments to members of the public around Spanish nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, M.A., E-mail: majg@csn.es [Consejo de Seguridad Nuclear (CSN), Pedro Justo Dorado Dellmans 11, E-28040 Madrid (Spain); Martin-Valdepenas, J.M.; Garcia-Talavera, M.; Martin-Matarranz, J.L.; Salas, M.R.; Serrano, J.I.; Ramos, L.M. [Consejo de Seguridad Nuclear (CSN), Pedro Justo Dorado Dellmans 11, E-28040 Madrid (Spain)

    2011-11-15

    In the frame of an epidemiological study carried out in the influence areas around the Spanish nuclear facilities (ISCIII-CSN, 2009. Epidemiological Study of The Possible Effect of Ionizing Radiations Deriving from The Operation of Spanish Nuclear Fuel Cycle Facilities on The Health of The Population Living in Their Vicinity. Final report December 2009. Ministerio de Ciencia e Innovacion, Instituto de Salud Carlos III, Consejo de Seguridad Nuclear. Madrid. Available from: (http://www.csn.es/images/stories/actualidad{sub d}atos/especiales/epidemiologico/epidemiological{sub s}tudy.pdf)), annual effective doses to public have been assessed by the Spanish Nuclear Safety Council (CSN) for over 45 years using a retrospective realistic-dose methodology. These values are compared with data from natural radiation exposure. For the affected population, natural radiation effective doses are in average 2300 times higher than effective doses due to the operation of nuclear installations (nuclear power stations and fuel cycle facilities). When considering the impact on the whole Spanish population, effective doses attributable to nuclear facilities represent in average 3.5 x 10{sup -5} mSv/y, in contrast to 1.6 mSv/y from natural radiation or 1.3 mSv/y from medical exposures. - Highlights: > Most comprehensive dose assessment to public by nuclear facilities ever done in Spain. > Dose to public is dominated by liquid effluent pathways for the power stations. > Dose to public is dominated by Rn inhalation for milling and mining facilities. > Average annual doses to public in influence areas are negligible (10 {mu}Sv/y or less). > Doses from facilities average 3.5 x 10{sup -2} {mu}Sv/y per person onto whole Spanish population.

  20. Realistic retrospective dose assessments to members of the public around Spanish nuclear facilities

    International Nuclear Information System (INIS)

    Jimenez, M.A.; Martin-Valdepenas, J.M.; Garcia-Talavera, M.; Martin-Matarranz, J.L.; Salas, M.R.; Serrano, J.I.; Ramos, L.M.

    2011-01-01

    In the frame of an epidemiological study carried out in the influence areas around the Spanish nuclear facilities (ISCIII-CSN, 2009. Epidemiological Study of The Possible Effect of Ionizing Radiations Deriving from The Operation of Spanish Nuclear Fuel Cycle Facilities on The Health of The Population Living in Their Vicinity. Final report December 2009. Ministerio de Ciencia e Innovacion, Instituto de Salud Carlos III, Consejo de Seguridad Nuclear. Madrid. Available from: (http://www.csn.es/images/stories/actualidad_datos/especiales/epidemiologico/epidemiological_study.pdf)), annual effective doses to public have been assessed by the Spanish Nuclear Safety Council (CSN) for over 45 years using a retrospective realistic-dose methodology. These values are compared with data from natural radiation exposure. For the affected population, natural radiation effective doses are in average 2300 times higher than effective doses due to the operation of nuclear installations (nuclear power stations and fuel cycle facilities). When considering the impact on the whole Spanish population, effective doses attributable to nuclear facilities represent in average 3.5 x 10 -5 mSv/y, in contrast to 1.6 mSv/y from natural radiation or 1.3 mSv/y from medical exposures. - Highlights: → Most comprehensive dose assessment to public by nuclear facilities ever done in Spain. → Dose to public is dominated by liquid effluent pathways for the power stations. → Dose to public is dominated by Rn inhalation for milling and mining facilities. → Average annual doses to public in influence areas are negligible (10 μSv/y or less). → Doses from facilities average 3.5 x 10 -2 μSv/y per person onto whole Spanish population.

  1. Implementation of a risk assessment tool based on a probabilistic safety assessment developed for radiotherapy practices

    International Nuclear Information System (INIS)

    Paz, A.; Godinez, V.; Lopez, R.

    2010-10-01

    The present work describes the implementation process and main results of the risk assessment to the radiotherapy practices with Linear Accelerators (Linac), with cobalt 60, and with brachytherapy. These evaluations were made throughout the risk assessment tool for radiotherapy practices SEVRRA (risk evaluation system for radiotherapy), developed at the Mexican National Commission in Nuclear Safety and Safeguards derived from the outcome obtained with the Probabilistic Safety Analysis developed at the Ibero-American Regulators Forum for these radiotherapy facilities. The methodology used is supported by risk matrices method, a mathematical tool that estimates the risk to the patient, radiation workers and public from mechanical failures, mis calibration of the devices, human mistakes, and so. The initiating events are defined as those undesirable events that, together with other failures, can produce a delivery of an over-dose or an under-dose of the medical prescribed dose, to the planned target volume, or a significant dose to non prescribed human organs. Initiating events frequency and reducer of its frequency (actions intended to avoid the accident) are estimated as well as robustness of barriers to those actions, such as mechanical switches, which detect and prevent the accident from occurring. The spectrum of the consequences is parameterized, and the actions performed to reduce the consequences are identified. Based on this analysis, a software tool was developed in order to simplify the evaluations to radiotherapy installations and it has been applied as a first step forward to some Mexican installations, as part of a national implementation process, the final goal is evaluation of all Mexican facilities in the near future. The main target and benefits of the SEVRRA implementation are presented in this paper. (Author)

  2. Implementation of a risk assessment tool based on a probabilistic safety assessment developed for radiotherapy practices

    Energy Technology Data Exchange (ETDEWEB)

    Paz, A.; Godinez, V.; Lopez, R., E-mail: abpaz@cnsns.gob.m [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan No. 779, Col. Narvarte, 03020 Mexico D. F. (Mexico)

    2010-10-15

    The present work describes the implementation process and main results of the risk assessment to the radiotherapy practices with Linear Accelerators (Linac), with cobalt 60, and with brachytherapy. These evaluations were made throughout the risk assessment tool for radiotherapy practices SEVRRA (risk evaluation system for radiotherapy), developed at the Mexican National Commission in Nuclear Safety and Safeguards derived from the outcome obtained with the Probabilistic Safety Analysis developed at the Ibero-American Regulators Forum for these radiotherapy facilities. The methodology used is supported by risk matrices method, a mathematical tool that estimates the risk to the patient, radiation workers and public from mechanical failures, mis calibration of the devices, human mistakes, and so. The initiating events are defined as those undesirable events that, together with other failures, can produce a delivery of an over-dose or an under-dose of the medical prescribed dose, to the planned target volume, or a significant dose to non prescribed human organs. Initiating events frequency and reducer of its frequency (actions intended to avoid the accident) are estimated as well as robustness of barriers to those actions, such as mechanical switches, which detect and prevent the accident from occurring. The spectrum of the consequences is parameterized, and the actions performed to reduce the consequences are identified. Based on this analysis, a software tool was developed in order to simplify the evaluations to radiotherapy installations and it has been applied as a first step forward to some Mexican installations, as part of a national implementation process, the final goal is evaluation of all Mexican facilities in the near future. The main target and benefits of the SEVRRA implementation are presented in this paper. (Author)

  3. Radionuclide transport and dose assessment modelling in biosphere assessment 2009

    International Nuclear Information System (INIS)

    Hjerpe, T.; Broed, R.

    2010-11-01

    Following the guidelines set forth by the Ministry of Trade and Industry (now Ministry of Employment and Economy), Posiva is preparing to submit a construction license application for the final disposal spent nuclear fuel at the Olkiluoto site, Finland, by the end of the year 2012. Disposal will take place in a geological repository implemented according to the KBS-3 method. The long-term safety section supporting the license application will be based on a safety case that, according to the internationally adopted definition, will be a compilation of the evidence, analyses and arguments that quantify and substantiate the safety and the level of expert confidence in the safety of the planned repository. This report documents in detail the conceptual and mathematical models and key data used in the landscape model set-up, radionuclide transport modelling, and radiological consequences analysis applied in the 2009 biosphere assessment. Resulting environmental activity concentrations in landscape model due to constant unit geosphere release rates, and the corresponding annual doses, are also calculated and presented in this report. This provides the basis for understanding the behaviour of the applied landscape model and subsequent dose calculations. (orig.)

  4. MODARIA WG5: Towards a practical guidance for including uncertainties in the results of dose assessment of routine releases

    Energy Technology Data Exchange (ETDEWEB)

    Mora, Juan C. [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas - CIEMAT (Spain); Telleria, Diego [International Atomic Energy Agency - IAEA (Austria); Al Neaimi, Ahmed [Emirates Nuclear Energy Corporation - ENEC (United Arab Emirates); Blixt Buhr, Anna Ma [Vattenfall AB (Sweden); Bonchuk, Iurii [Radiation Protection Institute - RPI (Ukraine); Chouhan, Sohan [Atomic Energy of Canada Limited - AECL (Canada); Chyly, Pavol [SE-VYZ (Slovakia); Curti, Adriana R. [Autoridad Regulatoria Nuclear - ARN (Argentina); Da Costa, Dejanira [Instituto de Radioprotecao e Dosimetria - IRD (Brazil); Duran, Juraj [VUJE Inc (Slovakia); Galeriu, Dan [Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN-HH (Romania); Haegg, Ann- Christin; Lager, Charlotte [Swedish Radiation Safety Authority - SSM (Sweden); Heling, Rudie [Nuclear Research and Consultancy Group - NRG (Netherlands); Ivanis, Goran; Shen, Jige [Ecometrix Incorporated (Canada); Iosjpe, Mikhail [Norwegian Radiation Protection Authority - NRPA (Norway); Krajewski, Pawel M. [Central Laboratory for Radiological Protection - CLOR (Poland); Marang, Laura; Vermorel, Fabien [Electricite de France - EdF (France); Mourlon, Christophe [Institut de Radioprotection et de Surete Nucleaire - IRSN (France); Perez, Fabricio F. [Belgian Nuclear Research Centre - SCK (Belgium); Woodruffe, Andrew [Federal Authority for Nuclear Regulation - FANR (United Arab Emirates); Zorko, Benjamin [Jozef Stefan Institute (Slovenia)

    2014-07-01

    MODARIA (Modelling and Data for Radiological Impact Assessments) project was launched in 2012 with the aim of improving the capabilities in radiation dose assessment by means of acquisition of improved data for model testing, model testing and comparison, reaching consensus on modelling philosophies, approaches and parameter values, development of improved methods and exchange of information. The project focuses on areas where uncertainties remain in the predictive capability of environmental models, emphasizing in reducing associated uncertainties or developing new approaches to strengthen the evaluation of the radiological impact. Within MODARIA, four main areas were defined, one of them devoted to Uncertainty and Variability. In this area four working groups were included, Working Group 5 dealing with the 'uncertainty and variability analysis for assessments of radiological impacts arising from routine discharges of radionuclides'. Whether doses are estimated by using measurement data, by applying models, or through a combination of measurements and calculations, the variability and uncertainty contribute to a distribution of possible values. The degree of variability and uncertainty is represented by the shape and extent of that distribution. The main objective of WG5 is to explore how to consider uncertainties and variabilities in the results of assessment of doses in planned situations for controlling the impact of routine releases from radioactive and nuclear installations to the environment. The final aim is to produce guidance for the calculation of uncertainties in these exposure situations and for the presentation of such results to the different stakeholders. To achieve that objective the main tasks identified were: to find tools and methods for uncertainty and variability analysis applicable to dose assessments in routine radioactive discharges, to define scenarios where information on uncertainty and variability of parameters is available

  5. Effect of Low-Dose MDCT and Iterative Reconstruction on Trabecular Bone Microstructure Assessment.

    Science.gov (United States)

    Kopp, Felix K; Holzapfel, Konstantin; Baum, Thomas; Nasirudin, Radin A; Mei, Kai; Garcia, Eduardo G; Burgkart, Rainer; Rummeny, Ernst J; Kirschke, Jan S; Noël, Peter B

    2016-01-01

    We investigated the effects of low-dose multi detector computed tomography (MDCT) in combination with statistical iterative reconstruction algorithms on trabecular bone microstructure parameters. Twelve donated vertebrae were scanned with the routine radiation exposure used in our department (standard-dose) and a low-dose protocol. Reconstructions were performed with filtered backprojection (FBP) and maximum-likelihood based statistical iterative reconstruction (SIR). Trabecular bone microstructure parameters were assessed and statistically compared for each reconstruction. Moreover, fracture loads of the vertebrae were biomechanically determined and correlated to the assessed microstructure parameters. Trabecular bone microstructure parameters based on low-dose MDCT and SIR significantly correlated with vertebral bone strength. There was no significant difference between microstructure parameters calculated on low-dose SIR and standard-dose FBP images. However, the results revealed a strong dependency on the regularization strength applied during SIR. It was observed that stronger regularization might corrupt the microstructure analysis, because the trabecular structure is a very small detail that might get lost during the regularization process. As a consequence, the introduction of SIR for trabecular bone microstructure analysis requires a specific optimization of the regularization parameters. Moreover, in comparison to other approaches, superior noise-resolution trade-offs can be found with the proposed methods.

  6. Negotiating NORM cleanup and land use limits: Practical use of dose assessment and cost benefit analysis

    International Nuclear Information System (INIS)

    Blanchard, A.D.H.

    1997-01-01

    Oil companies are presently faced with complex and costly environmental decisions, especially concerning NORM cleanup and disposal. Strict cleanup limits and disposal restrictions are established, in theory, to protect public health and environment. While public health is directly measured in terms of dose (mrem/yr), most NORM regulations adopt soil concentration limits to ensure future public health is maintained. These derived soil limits create the potential for unnecessary burden to operators without additional health benefit to society. Operators may use a dose assessment to show direct compliance with dose limits, negotiating less restrictive cleanup levels and land use limits. This paper discusses why a dose assessment is useful to Oilfield operators, NORM exposure scenarios and pathways, assessment advantages, variables and recommendations and one recent dose assessment application. Finally, a cost benefit analysis tool for regulatory negotiations will be presented allowing comparison of Oilfield NORM health benefit costs to that of other industries. One use for this tool--resulting in the savings of approximately $100,000--will be discussed

  7. Application of Biota Dose Assessment Committee Methodology to Assess Radiological Risk to Salmonids in the Hanford Reach of the Columbia River

    International Nuclear Information System (INIS)

    Poston, Ted M.; Antonio, Ernest J.; Peterson, Robert E.

    2002-01-01

    Protective guidance for biota in the U.S. Department of Energy's Graded Approach for Evaluating Radiation Doses to Aquatic and Terrestrial Biota is based on population level protection guides of 10 or 1 mGy.d-1, respectively. Several 'ecologically significant units' of Pacific salmon are listed under the Endangered Species Act. The Middle Columbia Steelhead unit is endangered and the adult steelhead spawn in the reach. The reach also supports one of the largest spawning populations of fall chinook salmon in the Northwest. The existence of the major spawning areas in the Hanford Reach has focused considerable attention on their ecological health by the U.S. Department of Energy, other federal and state regulatory agencies, and special interest groups. Dose assessments for developing salmonid embryos were performed for the hypothetical exposure to tritium, strontium-90, technetium-99, iodine-129, and uranium isotopes at specific sites on the Hanford Reach. These early life stages are potentially exposed in some areas of the Hanford Reach to radiological contaminants that enter the river via shoreline seeps and upwelling through the river substrate. At the screening level, one site approached the dose guideline of 10 mGy.d-1 established with the RAD-BCG methodology and exceeded a precautionary benchmark of 2.5 mGy.d-1. Special status of listed species affords these populations more consideration when assessing potential impacts of exposure to radionuclides and other contaminants associated with the Hanford Site operations. The evolution of dose benchmarks for aquatic organisms and consideration of precautionary principal and cumulative impacts are discussed in this paper.

  8. Hormesis: from marginalization to mainstream A case for hormesis as the default dose-response model in risk assessment

    International Nuclear Information System (INIS)

    Calabrese, Edward J.

    2004-01-01

    The paper provides an account of how the hormetic dose response has emerged in recent years as a serious dose-response model in toxicology and risk assessment after decades of extreme marginalization. In addition to providing the toxicological basis of this dose-response revival, the paper reexamines the concept of a default dose model in toxicology and risk assessment and makes the argument that the hormetic model satisfies criteria (e.g., generalizability, frequency, application to risk assessment endpoints, false positive/negative potential, requirements for hazard assessment, reliability of estimating risks, capacity for validation of risk estimates, public health implications of risk estimates) for such a default model better than its chief competitors, the threshold and linear at low dose models. The selection of the hormetic model as the default model in risk assessment for noncarcinogens and specifically for carcinogens would have a profound impact on the practice of risk assessment and its societal implications

  9. Assessment of dose measurement uncertainty using RisoScan

    International Nuclear Information System (INIS)

    Helt-Hansen, Jakob; Miller, Arne

    2006-01-01

    The dose measurement uncertainty of the dosimeter system RisoScan, office scanner and Riso B3 dosimeters has been assessed by comparison with spectrophotometer measurements of the same dosimeters. The reproducibility and the combined uncertainty were found to be approximately 2% and 4%, respectively, at one standard deviation. The subroutine in RisoScan for electron energy measurement is shown to give results that are equivalent to the measurements with a scanning spectrophotometer

  10. Assessing patient dose in interventional fluoroscopy using patient-dependent hybrid phantoms

    Science.gov (United States)

    Johnson, Perry Barnett

    Interventional fluoroscopy uses ionizing radiation to guide small instruments through blood vessels or other body pathways to sites of clinical interest. The technique represents a tremendous advantage over invasive surgical procedures, as it requires only a small incision, thus reducing the risk of infection and providing for shorter recovery times. The growing use and increasing complexity of interventional procedures, however, has resulted in public health concerns regarding radiation exposures, particularly with respect to localized skin dose. Tracking and documenting patient-specific skin and internal organ dose has been specifically identified for interventional fluoroscopy where extended irradiation times, multiple projections, and repeat procedures can lead to some of the largest doses encountered in radiology. Furthermore, inprocedure knowledge of localized skin doses can be of significant clinical importance to managing patient risk and in training radiology residents. In this dissertation, a framework is presented for monitoring the radiation dose delivered to patients undergoing interventional procedures. The framework is built around two key points, developing better anthropomorphic models, and designing clinically relevant software systems for dose estimation. To begin, a library of 50 hybrid patient-dependent computational phantoms was developed based on the UF hybrid male and female reference phantoms. These phantoms represent a different type of anthropomorphic model whereby anthropometric parameters from an individual patient are used during phantom selection. The patient-dependent library was first validated and then used in two patient-phantom matching studies focused on cumulative organ and local skin dose. In terms of organ dose, patient-phantom matching was shown most beneficial for estimating the dose to large patients where error associated with soft tissue attenuation differences could be minimized. For small patients, inherent difference

  11. The FOCON model to assess doses due to the atmospheric radioactive discharges of nuclear facilities during normal operation

    International Nuclear Information System (INIS)

    Rommens, C.; Morin, A.; Merle-Szeremeta, A.

    1999-01-01

    The FOCON model to assess doses due to the atmospheric radioactive discharges of nuclear facilities during normal operation. To assess the dosimetric impact to the public due to atmospheric radioactive discharges of nuclear facilities during normal operation, the Institute for Protection and Nuclear Safety has developed the FOCON96 code. FOCON96 calculates the dispersion of gases and aerosols into the environment (atmosphere contamination and ground deposition), their transfer in the biosphere (soils, plants and animals) and their impact to a member of the public (individual effective and equivalent doses, external exposure to the plume and to the deposits, internal exposure by inhalation and ingestion). FOCON96 uses ergonomic windows and proposes many capabilities (modular architecture, default values, choice of libraries, access to all the parameters of the models, listing or results, management of result files, calculations made directly, etc.). In the European context, and intercomparison with the PC-CREAM code, developed by the National Radiological Protection Board, has shown the coherence of the results of the two codes. A comparison of the windows and capabilities has shown that FOCON96 was easier to use. FOCON96 is not adapted to calculate the doses received during one particular year that are due to the discharges of a facility in operation for a long period of time. An evolution of the software will be considered if this kind of assessment is generalized. (authors)

  12. In vivo assessment of catheter positioning accuracy and prolonged irradiation time on liver tolerance dose after single-fraction 192Ir high-dose-rate brachytherapy

    Directory of Open Access Journals (Sweden)

    Kropf Siegfried

    2011-09-01

    Full Text Available Abstract Background To assess brachytherapy catheter positioning accuracy and to evaluate the effects of prolonged irradiation time on the tolerance dose of normal liver parenchyma following single-fraction irradiation with 192 Ir. Materials and methods Fifty patients with 76 malignant liver tumors treated by computed tomography (CT-guided high-dose-rate brachytherapy (HDR-BT were included in the study. The prescribed radiation dose was delivered by 1 - 11 catheters with exposure times in the range of 844 - 4432 seconds. Magnetic resonance imaging (MRI datasets for assessing irradiation effects on normal liver tissue, edema, and hepatocyte dysfunction, obtained 6 and 12 weeks after HDR-BT, were merged with 3D dosimetry data. The isodose of the treatment plan covering the same volume as the irradiation effect was taken as a surrogate for the liver tissue tolerance dose. Catheter positioning accuracy was assessed by calculating the shift between the 3D center coordinates of the irradiation effect volume and the tolerance dose volume for 38 irradiation effects in 30 patients induced by catheters implanted in nearly parallel arrangement. Effects of prolonged irradiation were assessed in areas where the irradiation effect volume and tolerance dose volume did not overlap (mismatch areas by using a catheter contribution index. This index was calculated for 48 irradiation effects induced by at least two catheters in 44 patients. Results Positioning accuracy of the brachytherapy catheters was 5-6 mm. The orthogonal and axial shifts between the center coordinates of the irradiation effect volume and the tolerance dose volume in relation to the direction vector of catheter implantation were highly correlated and in first approximation identically in the T1-w and T2-w MRI sequences (p = 0.003 and p p = 0.001 and p = 0.004, respectively. There was a significant shift of the irradiation effect towards the catheter entry site compared with the planned dose

  13. Cone beam computed tomography radiation dose and image quality assessments.

    Science.gov (United States)

    Lofthag-Hansen, Sara

    2010-01-01

    Diagnostic radiology has undergone profound changes in the last 30 years. New technologies are available to the dental field, cone beam computed tomography (CBCT) as one of the most important. CBCT is a catch-all term for a technology comprising a variety of machines differing in many respects: patient positioning, volume size (FOV), radiation quality, image capturing and reconstruction, image resolution and radiation dose. When new technology is introduced one must make sure that diagnostic accuracy is better or at least as good as the one it can be expected to replace. The CBCT brand tested was two versions of Accuitomo (Morita, Japan): 3D Accuitomo with an image intensifier as detector, FOV 3 cm x 4 cm and 3D Accuitomo FPD with a flat panel detector, FOVs 4 cm x 4 cm and 6 cm x 6 cm. The 3D Accuitomo was compared with intra-oral radiography for endodontic diagnosis in 35 patients with 46 teeth analyzed, of which 41 were endodontically treated. Three observers assessed the images by consensus. The result showed that CBCT imaging was superior with a higher number of teeth diagnosed with periapical lesions (42 vs 32 teeth). When evaluating 3D Accuitomo examinations in the posterior mandible in 30 patients, visibility of marginal bone crest and mandibular canal, important anatomic structures for implant planning, was high with good observer agreement among seven observers. Radiographic techniques have to be evaluated concerning radiation dose, which requires well-defined and easy-to-use methods. Two methods: CT dose index (CTDI), prevailing method for CT units, and dose-area product (DAP) were evaluated for calculating effective dose (E) for both units. An asymmetric dose distribution was revealed when a clinical situation was simulated. Hence, the CTDI method was not applicable for these units with small FOVs. Based on DAP values from 90 patient examinations effective dose was estimated for three diagnostic tasks: implant planning in posterior mandible and

  14. Radiological dose assessment related to management of naturally occurring radioactive materials generated by the petroleum industry

    International Nuclear Information System (INIS)

    Smith, K.P.; Blunt, D.L.; Williams, G.P.

    1996-09-01

    A preliminary radiological dose assessment of equipment decontamination, subsurface disposal, landspreading, equipment smelting, and equipment burial was conducted to address concerns regarding the presence of naturally occurring radioactive materials (NORM) in production waste streams. The assessment estimated maximum individual dose equivalents for workers and the general public. Sensitivity analyses of certain input parameters also were conducted. On the basis of this assessment, it is concluded that (1) regulations requiring workers to wear respiratory protection during equipment cleaning operations are likely to result in lower worker doses, (2) underground injection and downhole encapsulation of NORM wastes present a negligible risk to the general public, and (3) potential doses to workers and the general public related to smelting NORM-contaminated equipment can be controlled by limiting the contamination level of the initial feed. It is recommended that (1) NORM wastes be further characterized to improve studies of potential radiological doses; (2) states be encouraged to permit subsurface disposal of NORM more readily, provided further assessments support this study; results; (3) further assessment of landspreading NORM wastes be conducted; and (4) the political, economic, sociological, and nonradiological issues related to smelting NORM-contaminated equipment be studied to fully examine the feasibility of this disposal option

  15. Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging

    International Nuclear Information System (INIS)

    Goma, Carles; Ruiz, Agustin; Jornet, Nuria; Latorre, Artur; Pallerol, Rosa M.; Carrasco, Pablo; Eudaldo, Teresa; Ribas, Montserrat

    2011-01-01

    Purpose: In the present era of cone-beam CT scanners, the use of the standardized CTDI 100 as a surrogate of the idealized CTDI is strongly discouraged and, consequently, so should be the use of the dose-length product (DLP) as an estimate of the total energy imparted to the patient. However, the DLP is still widely used as a reference quantity to normalize the effective dose for a given scan protocol mainly because the CTDI 100 is an easy-to-measure quantity. The aim of this article is therefore to describe a method for radiation dose assessment in large cone-beam single axial scans, which leads to a straightforward estimation of the total energy imparted to the patient. The authors developed a method accessible to all medical physicists and easy to implement in clinical practice in an attempt to update the bridge between CT dosimetry and the estimation of the effective dose. Methods: The authors used commercially available material and a simple mathematical model. The method described herein is based on the dosimetry paradigm introduced by the AAPM Task Group 111. It consists of measuring the dose profiles at the center and the periphery of a long body phantom with a commercial solid-state detector. A weighted dose profile is then calculated from these measurements. To calculate the CT dosimetric quantities analytically, a Gaussian function was fitted to the dose profile data. Furthermore, the Gaussian model has the power to condense the z-axis information of the dose profile in two parameters: The single-scan central dose, f(0), and the width of the profile, σ. To check the energy dependence of the solid-state detector, the authors compared the dose profiles to measurements made with a small volume ion chamber. To validate the overall method, the authors compared the CTDI 100 calculated analytically to the measurement made with a 100 mm pencil ion chamber. Results: For the central and weighted dose profiles, the authors found a good agreement between the

  16. Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging

    Energy Technology Data Exchange (ETDEWEB)

    Goma, Carles; Ruiz, Agustin; Jornet, Nuria; Latorre, Artur; Pallerol, Rosa M.; Carrasco, Pablo; Eudaldo, Teresa; Ribas, Montserrat [Servei de Radiofisica i Radioproteccio, Hospital de la Santa Creu i Sant Pau, Sant Antoni Maria Claret 167, 08025 Barcelona (Spain)

    2011-03-15

    Purpose: In the present era of cone-beam CT scanners, the use of the standardized CTDI{sub 100} as a surrogate of the idealized CTDI is strongly discouraged and, consequently, so should be the use of the dose-length product (DLP) as an estimate of the total energy imparted to the patient. However, the DLP is still widely used as a reference quantity to normalize the effective dose for a given scan protocol mainly because the CTDI{sub 100} is an easy-to-measure quantity. The aim of this article is therefore to describe a method for radiation dose assessment in large cone-beam single axial scans, which leads to a straightforward estimation of the total energy imparted to the patient. The authors developed a method accessible to all medical physicists and easy to implement in clinical practice in an attempt to update the bridge between CT dosimetry and the estimation of the effective dose. Methods: The authors used commercially available material and a simple mathematical model. The method described herein is based on the dosimetry paradigm introduced by the AAPM Task Group 111. It consists of measuring the dose profiles at the center and the periphery of a long body phantom with a commercial solid-state detector. A weighted dose profile is then calculated from these measurements. To calculate the CT dosimetric quantities analytically, a Gaussian function was fitted to the dose profile data. Furthermore, the Gaussian model has the power to condense the z-axis information of the dose profile in two parameters: The single-scan central dose, f(0), and the width of the profile, {sigma}. To check the energy dependence of the solid-state detector, the authors compared the dose profiles to measurements made with a small volume ion chamber. To validate the overall method, the authors compared the CTDI{sub 100} calculated analytically to the measurement made with a 100 mm pencil ion chamber. Results: For the central and weighted dose profiles, the authors found a good

  17. Animal data on GI-tract uptake of plutonium - implications for environmental dose assessments

    International Nuclear Information System (INIS)

    Kocher, D.C.; Ryan, M.T.

    1983-01-01

    A selection of published data on GI-tract uptake of ingested plutonium in animals is reviewed for the purpose of estimating an uptake fraction which would be appropriate for environmental dose assessments in adult humans. Recent data in the adult rat and guinea pig suggest that a GI-tract uptake fraction of 10 -3 would be a reasonable and prudent choice for ingestion of environmental plutonium by adults. This value is a factor of ten larger than the value currently recommended by the International Commission on Radiological Protection for assessing doses from occupational exposures. (author)

  18. Prototype development or multi-cavity ion chamber for depth dose measurement

    International Nuclear Information System (INIS)

    Nayak, M.K.; Sahu, T.K.; Haridas, G.; Bandyopadhyay, Tapas; Tripathi, R.M.; Nandedkar, R.V.

    2016-01-01

    In high energy electron accelerators, when the electrons interact with vacuum chamber or surrounding structural material, Bremsstrahlung x-rays are produced. It is having a broad spectrum extending up to the electron energies. Dose measured as a function of depth due to electromagnetic cascade will give rise to depth dose curve. To measure the online depth dose profile in an absorber medium, when high energy electron or Bremsstrahlung is incident, a prototype Multi-Cavity Ion Chamber (MCIC) detector is developed. The paper describes the design and development of the MCIC for measurement of depth dose profile

  19. Investigation of radioactive pollution on land at Thule and assessment of radiation doses

    International Nuclear Information System (INIS)

    2011-12-01

    Risoe National Laboratory at the Technical University of Denmark has carried out research on the terrestrial contamination in the Thule area, Greenland, after the radioactive contents of four nuclear weapons were dispersed following the crash of an American B-52 bomber in 1968. The results of this research are described in the report ''Thule-2007 - Investigation of radioactive pollution on land''. Based on this report, the National Board of Health made an assessment of radiation doses and the risk for individuals in the Thule area. The results of the assessment are described in the report ''The Thule accident. Assessment of radiation doses from terrestrial radioactive contamination''. The present report is a summary of these two reports. (ln)

  20. eDrugCalc: an online self-assessment package to enhance medical students' drug dose calculation skills.

    Science.gov (United States)

    McQueen, Daniel S; Begg, Michael J; Maxwell, Simon R J

    2010-10-01

    Dose calculation errors can cause serious life-threatening clinical incidents. We designed eDrugCalc as an online self-assessment tool to develop and evaluate calculation skills among medical students. We undertook a prospective uncontrolled study involving 1727 medical students in years 1-5 at the University of Edinburgh. Students had continuous access to eDrugCalc and were encouraged to practise. Voluntary self-assessment was undertaken by answering the 20 questions on six occasions over 30 months. Questions remained fixed but numerical variables changed so each visit required a fresh calculation. Feedback was provided following each answer. Final-year students had a significantly higher mean score in test 6 compared with test 1 [16.6, 95% confidence interval (CI) 16.2, 17.0 vs. 12.6, 95% CI 11.9, 13.4; n= 173, P variable in all tests with 2.7% of final-year students scoring formative dose-calculation package and encouragement to develop their numeracy. Further research is required to establish whether eDrugCalc reduces calculation errors made in clinical practice. © 2010 The Authors. British Journal of Clinical Pharmacology © 2010 The British Pharmacological Society.

  1. 3D delivered dose assessment using a 4DCT-based motion model

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Weixing; Hurwitz, Martina H.; Williams, Christopher L.; Dhou, Salam; Berbeco, Ross I.; Mishra, Pankaj, E-mail: wcai@lroc.harvard.edu, E-mail: jhlewis@lroc.harvard.edu; Lewis, John H., E-mail: wcai@lroc.harvard.edu, E-mail: jhlewis@lroc.harvard.edu [Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States); Seco, Joao [Francis H. Burr Proton Therapy Center, Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2015-06-15

    Purpose: The purpose of this work is to develop a clinically feasible method of calculating actual delivered dose distributions for patients who have significant respiratory motion during the course of stereotactic body radiation therapy (SBRT). Methods: A novel approach was proposed to calculate the actual delivered dose distribution for SBRT lung treatment. This approach can be specified in three steps. (1) At the treatment planning stage, a patient-specific motion model is created from planning 4DCT data. This model assumes that the displacement vector field (DVF) of any respiratory motion deformation can be described as a linear combination of some basis DVFs. (2) During the treatment procedure, 2D time-varying projection images (either kV or MV projections) are acquired, from which time-varying “fluoroscopic” 3D images of the patient are reconstructed using the motion model. The DVF of each timepoint in the time-varying reconstruction is an optimized linear combination of basis DVFs such that the 2D projection of the 3D volume at this timepoint matches the projection image. (3) 3D dose distribution is computed for each timepoint in the set of 3D reconstructed fluoroscopic images, from which the total effective 3D delivered dose is calculated by accumulating deformed dose distributions. This approach was first validated using two modified digital extended cardio-torso (XCAT) phantoms with lung tumors and different respiratory motions. The estimated doses were compared to the dose that would be calculated for routine 4DCT-based planning and to the actual delivered dose that was calculated using “ground truth” XCAT phantoms at all timepoints. The approach was also tested using one set of patient data, which demonstrated the application of our method in a clinical scenario. Results: For the first XCAT phantom that has a mostly regular breathing pattern, the errors in 95% volume dose (D95) are 0.11% and 0.83%, respectively for 3D fluoroscopic images

  2. 3D delivered dose assessment using a 4DCT-based motion model

    International Nuclear Information System (INIS)

    Cai, Weixing; Hurwitz, Martina H.; Williams, Christopher L.; Dhou, Salam; Berbeco, Ross I.; Mishra, Pankaj; Lewis, John H.; Seco, Joao

    2015-01-01

    Purpose: The purpose of this work is to develop a clinically feasible method of calculating actual delivered dose distributions for patients who have significant respiratory motion during the course of stereotactic body radiation therapy (SBRT). Methods: A novel approach was proposed to calculate the actual delivered dose distribution for SBRT lung treatment. This approach can be specified in three steps. (1) At the treatment planning stage, a patient-specific motion model is created from planning 4DCT data. This model assumes that the displacement vector field (DVF) of any respiratory motion deformation can be described as a linear combination of some basis DVFs. (2) During the treatment procedure, 2D time-varying projection images (either kV or MV projections) are acquired, from which time-varying “fluoroscopic” 3D images of the patient are reconstructed using the motion model. The DVF of each timepoint in the time-varying reconstruction is an optimized linear combination of basis DVFs such that the 2D projection of the 3D volume at this timepoint matches the projection image. (3) 3D dose distribution is computed for each timepoint in the set of 3D reconstructed fluoroscopic images, from which the total effective 3D delivered dose is calculated by accumulating deformed dose distributions. This approach was first validated using two modified digital extended cardio-torso (XCAT) phantoms with lung tumors and different respiratory motions. The estimated doses were compared to the dose that would be calculated for routine 4DCT-based planning and to the actual delivered dose that was calculated using “ground truth” XCAT phantoms at all timepoints. The approach was also tested using one set of patient data, which demonstrated the application of our method in a clinical scenario. Results: For the first XCAT phantom that has a mostly regular breathing pattern, the errors in 95% volume dose (D95) are 0.11% and 0.83%, respectively for 3D fluoroscopic images

  3. Feasibility study for the assessment of the exposed dose with TENORM added in consumer products

    International Nuclear Information System (INIS)

    Yoo, Do Hyeon; Lee, Hyun Cheol; Shin, Wook-Geun; Min, Chul Hee; Ha, Wi-Ho; Yoo, Jae Ryong; Yoon, Seok-Won; Lee, Jiyon; Choi, Won-Chul

    2015-01-01

    Consumer products including naturally occurring radioactive material have been distributed widely in human life. The potential hazard of the excessively added technically enhanced naturally occurring radioactive material (TENORM) in consumer products should be assessed. The aim of this study is to evaluate the organ equivalent dose and the annual effective dose with the usage of the TENORM added in paints. The activities of gammas emitted from natural radionuclides in the five types of paints were measured with the high-purity germanium detector, and the annual effective dose was assessed with the computational human phantom and the Monte Carlo method. The results show that uranium and thorium series were mainly measured over the five paints. Based on the exposure scenario of the paints in the room, the highest effective dose was evaluated as <1 mSv y -1 of the public dose limit. (authors)

  4. MOSFET assessment of radiation dose delivered to mice using the Small Animal Radiation Research Platform (SARRP).

    Science.gov (United States)

    Ngwa, Wilfred; Korideck, Houari; Chin, Lee M; Makrigiorgos, G Mike; Berbeco, Ross I

    2011-12-01

    The Small Animal Radiation Research Platform (SARRP) is a novel isocentric irradiation system that enables state-of-the-art image-guided radiotherapy research to be performed with animal models. This paper reports the results obtained from investigations assessing the radiation dose delivered by the SARRP to different anatomical target volumes in mice. Surgically implanted metal oxide semiconductor field effect transistors (MOSFET) dosimeters were employed for the dose assessment. The results reveal differences between the calculated and measured dose of -3.5 to 0.5%, -5.2 to -0.7%, -3.9 to 0.5%, -5.9 to 2.5%, -5.5 to 0.5%, and -4.3 to 0% for the left kidney, liver, pancreas, prostate, left lung, and brain, respectively. Overall, the findings show less than 6% difference between the delivered and calculated dose, without tissue heterogeneity corrections. These results provide a useful assessment of the need for tissue heterogeneity corrections in SARRP dose calculations for clinically relevant tumor model sites.

  5. Development of a Method to Assess the Radiation Dose due to Internal Exposure to Short-lived Radioactive Materials

    International Nuclear Information System (INIS)

    Benmaman, D.; Koch, J.; Ribak, J.

    2014-01-01

    Work with radioactive materials requires monitoring of the employees' exposure to ionizing radiation. Employees may be exposed to radiation from internal and/or external exposure. Control of external exposure is mostly conducted through personal radiation dosimeters provided to employees. Control of internal exposure can be performed by measuring the concentration of radioactive substances excreted in urine or through whole-body counting in which the entire body or target organs are scanned with a sensitive detector system (1). According to the regulations in Israel an employee that may be internally exposed must undergo an exposure control at least once every three months. The idea lying behind the control of internal exposure by urine testing is that if radioactive material has penetrated into the employee body, it can be detected even if the test is performed once every three months. A model was fitted for each element describing its dispersion in the body and its excretion therefrom (2). By means of this model, one can estimate the activity that entered the body and calculate the resulting radiation dose to which the worker was exposed. There is a problem to implement this method when it comes to short-lived radioactive materials, for which it is very likely that the material that penetrated into the body has decayed and cannot be detected by testing once every three months. As a result, workers with short-lived radioactive materials are presently not monitored for internal exposure, in contradiction to the requirements of the Safety at Work Regulations. The purpose of the study is to develop an alternative method to assess the amount of radioactive material absorbed in the body and the resulting radiation dose due to internal exposure of workers to short-lived radioactive materials

  6. Assessment of mean glandular dose to patients from digital mammography systems

    International Nuclear Information System (INIS)

    Pwamang, Caroline K.

    2016-07-01

    Mean glandular dose assessment of patients undergoing digital mammography examination has been done. A total of 297 patient data was used for the study. Basic Quality Control tests were done to ascertain the performance of the equipment used. The results of Quality Control tests indicated that the three Mammography units used for this study were functioning within the internationally acceptable performance criteria. Patients with a breast thickness of 30 mm within the two age groups of 40-49 yrs and 50-64 yrs received doses slightly higher than the acceptable dose levels. A patient in the category 40-49 yrs with breast thickness of 30 mm received 1.83 mGy as calculated Mean Glandular Dose, 2.10 mGy was the recorded dose and 1.58 mGy was recorded under the age group 50-64 yrs. These values have deviated by -22%, -40%, and -5.33% respectively from 1.5 mGy which is the recommended dose for a breast thickness of 30 mm. Also patients with breast thickness of 70 mm under the age group 40–49 yrs had a recorded dose of 6.58 mGy, which deviated by -1.21% from the recommended value of 6.5 mGy for that breast thickness. Aside these values, all the other values were within the recommended dose values. The percentage deviation between the recommended values and the calculated values was within ±25% which was a working limit that was set for this work. Doses delivered by the Full-field Digital mammography equipment were higher than doses delivered by the Computered Radiography equipment. The calculated Mean Glandular Doses for the three facilities were within recommended dose values. (author)

  7. Issues of assessment of doses from natural sources in working conditions: implications for the unified state system of individual dose monitoring

    Directory of Open Access Journals (Sweden)

    T. A. Kormanovskaya

    2017-01-01

    Full Text Available The aims of the work are: 1 an analysis of information on radiation doses from natural sources of ionizing radiation of employees of enterprises in some industries of the Russian Federation and 2 an assessment of the state of registration of doses from natural sources in working conditions in the Unified System of Individual Dose Control. Materials and methods. The analysis was performed on the results of the operation of the Federal database of radiation doses of the population due to natural and artificial radiation background in 2013–2015 on the basis of the forms of the Federal statistical observation No. 4-DOZ in terms of collecting information on the radiation doses of workers in some non-nuclear industries due to natural sources of ionizing radiation. Results. Analysis of enterprises in 17 industries in 23 regions of Russia connected with the specificity of production processes showed cases of natural exposure of workers at the dose level exceeding 5 mSv/year. We have identified those branches of industry, for which the doses were close to 5 mSv/year.Examples of reducing the radiation doses by reducing the time spent by workers in workplaces with high levels of radiation are given. The problems of insufficient representativeness of the sample data are due to the lack of interaction of the management of industrial enterprises with the bodies of the Rospotrebnadzor. The obtained data allow speaking about the problem of assessing the quality of radiation control in the organizations where additional exposure of workers from natural radiation sources is expected. It is necessary to create a system of regulatory and procedural documents to solve the problem at the national level.

  8. Evaluation of various approaches for assessing dose indicators and patient organ doses resulting from radiotherapy cone-beam CT

    International Nuclear Information System (INIS)

    Rampado, Osvaldo; Giglioli, Francesca Romana; Rossetti, Veronica; Ropolo, Roberto; Fiandra, Christian; Ragona, Riccardo

    2016-01-01

    Purpose: The aim of this study was to evaluate various approaches for assessing patient organ doses resulting from radiotherapy cone-beam CT (CBCT), by the use of thermoluminescent dosimeter (TLD) measurements in anthropomorphic phantoms, a Monte Carlo based dose calculation software, and different dose indicators as presently defined. Methods: Dose evaluations were performed on a CBCT Elekta XVI (Elekta, Crawley, UK) for different protocols and anatomical regions. The first part of the study focuses on using PCXMC software (PCXMC 2.0, STUK, Helsinki, Finland) for calculating organ doses, adapting the input parameters to simulate the exposure geometry, and beam dose distribution in an appropriate way. The calculated doses were compared to readouts of TLDs placed in an anthropomorphic Rando phantom. After this validation, the software was used for analyzing organ dose variability associated with patients’ differences in size and gender. At the same time, various dose indicators were evaluated: kerma area product (KAP), cumulative air-kerma at the isocenter (K_a_i_r), cone-beam dose index, and central cumulative dose. The latter was evaluated in a single phantom and in a stack of three adjacent computed tomography dose index phantoms. Based on the different dose indicators, a set of coefficients was calculated to estimate organ doses for a range of patient morphologies, using their equivalent diameters. Results: Maximum organ doses were about 1 mGy for head and neck and 25 mGy for chest and pelvis protocols. The differences between PCXMC and TLDs doses were generally below 10% for organs within the field of view and approximately 15% for organs at the boundaries of the radiation beam. When considering patient size and gender variability, differences in organ doses up to 40% were observed especially in the pelvic region; for the organs in the thorax, the maximum differences ranged between 20% and 30%. Phantom dose indexes provided better correlation with organ doses

  9. Internal dose assessment in nuclear medicine: fetal doses due to radiopharmaceutical administration to the mother

    International Nuclear Information System (INIS)

    Rojo, Ana M.; Michelin, Severino C.

    2004-01-01

    The objective of this publication is to present a guideline for the dose assessment through a comprehensive introduction of knowledge on ionizing radiation, radiation protection during pregnancy and fetal dosimetry for physician and other professionals involved in nuclear medicine practices. It contains tables with recommended dose estimates at all stages of pregnancy for many radiopharmaceuticals. Compounds for which some information was available regarding placental crossover are shown in shaded rows. It includes the most common diagnostic and therapy practices in nuclear medicine considering the four radioactive isotopes selected: 99m Tc, 131 I, 201 Tl and 67 Ga. There is a special case included, it is when conception occurs after the iodine has been administered. In almost every case, the diagnostic benefit to the mother outweighs the risk of any irradiation of the fetus. However, there is one situation in which severe fetal injury can be incurred from administering a radiopharmaceutical to the mother, and that is use of iodine-131 therapy for ablation of the thyroid in cases of hyperthyroidism or carcinoma. Radioactive iodine readily crosses the placenta and concentrates in the fetal thyroid, where, because of its small organ mass, high radiation doses are received. (author)

  10. Quantifying remarks to the question of uncertainties of the 'general dose assessment fundamentals'

    International Nuclear Information System (INIS)

    Brenk, H.D.; Vogt, K.J.

    1982-12-01

    Dose prediction models are always subject to uncertainties due to a number of factors including deficiencies in the model structure and uncertainties of the model input parameter values. In lieu of validation experiments the evaluation of these uncertainties is restricted to scientific judgement. Several attempts have been made in the literature to evaluate the uncertainties of the current dose assessment models resulting from uncertainties of the model input parameter values using stochastic approaches. Less attention, however, has been paid to potential sources of systematic over- and underestimations of the predicted doses due to deficiencies in the model structure. The present study addresses this aspect with regard to dose assessment models currently used for regulatory purposes. The influence of a number of basic simplifications and conservative assumptions has been investigated. Our systematic approach is exemplified by a comparison of doses evaluated on the basis of the regulatory guide model and a more realistic model respectively. This is done for 3 critical exposure pathways. As a result of this comparison it can be concluded that the currently used regularoty-type models include significant safety factors resulting in a systematic overprediction of dose to man up to two orders of magnitude. For this reason there are some indications that these models usually more than compensate the bulk of the stochastic uncertainties caused by the variability of the input parameter values. (orig.) [de

  11. General guidelines for the Assessment of Internal Dose from Monitoring Data (Project IDEAS)

    International Nuclear Information System (INIS)

    Doerfel, H.; Andrasi, A.; Bailey, M.; Blanchardon, E.; Berkovski, V.; Castellani, C. M.; Hurtgen, C.; Jourdain, J. R.; LeGuen, B.; Puncher, M.

    2004-01-01

    In recent major international intercomparison exercises on intake and internal dose assessments from monitoring data the results calculated by different participants varied significantly. This was mainly due to the broad variety of methods and assumptions applied in the assessment procedure. Based on these experiences the need for harmonisation of the procedures has been formulated within an EU research project under the 5th Framework Programme. The aim of the project, IDEAS, is to develop general guidelines for standardising assessments of intakes and internal doses. The IDEAS project started in October 2001 and will end in March 2005. Eight institutions from seven European countries are participating. Inputs from internal dosimetry professionals from across Europe are also being used to ensure a broad consensus in the outcome of the project. The IDEAS project is closely related to some goals of the work of Committee 2 of the ICRP and since 2003 there has been close cooperation between the two groups. To ensure that the guidelines are applicable to a wide range of practical situations, the first step has been to compile a database of well-documented cases of internal contamination. In parallel, an improved version of an existing software package has been developed and distributed to the partners for further use. A large number of cases from the database have been evaluated independently by partners in the project using the same software and the results have been reviewed. Based on these evaluations guidelines are being drafted and will be discussed with dosimetry professionals from around the world by means of a virtual workshop on the Internet early in 2004. The guidelines will be revised and refined on the basis of the experiences and discussions of this virtual workshop and the outcome of an intercomparison exercise organised as part of the project. This will be open to all internal dosimetry professionals. (Author) 10 refs

  12. Image quality evaluation and patient dose assessment of medical fluoroscopic X-ray systems: A national study

    International Nuclear Information System (INIS)

    Economides, S.; Hourdakis, C. J.; Kalivas, N.; Kalathaki, M.; Simantirakis, G.; Tritakis, P.; Manousaridis, G.; Vogiatzi, S.; Kipouros, P.; Boziari, A.; Kamenopoulou, V.

    2008-01-01

    This study presents the results from a survey conducted by the Greek Atomic Energy Commission (GAEC), during the period 1998-2003, in 530 public and private owned fluoroscopic X-ray systems in Greece. Certain operational parameters for conventional and remote control systems were assessed, according to a quality control protocol developed by GAEC on the basis of the current literature. Public (91.5%) and private (81.5%) owned fluoroscopic units exhibit high-contrast resolution values over 1 lp mm -1 . Moreover, 88.5 and 87.1% of the fluoroscopic units installed in the public and private sector, respectively, present Maximum Patient Entrance Kerma Rate values lower than 100 mGy min -1 . Additionally, 68.3% of the units assessed were found to perform within the acceptance limits. Finally, the third quartile of the Entrance Surface Dose Rate distribution was estimated according to the Dose Reference Level definition and found equal to 35 mGy min -1 . (authors)

  13. An updated dose assessment for a U.S. Nuclear Test Site - Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Bogen, K.T.; Conrado, C.L.

    1995-10-01

    On March 1, 1954, a nuclear weapon test, code-named BRAVO, conducted at Bikini Atoll in the northern Marshall Islands contaminated the major residence island. There has been a continuing effort since 1977 to refine dose assessments for resettlement options at Bikini Atoll. Here we provide a radiological dose assessment for the main residence island, Bikini, using extensive radionuclide concentration data derived from analysis of food crops, ground water, cistern water, fish and other marine species, animals, air, and soil collected at Bikini Island as part of our continuing research and monitoring program that began in 1975. The unique composition of coral soil greatly alters the relative contribution of cesium-137 ( 137 Cs) and strontium-90 ( 90 Sr) to the total estimated dose relative to expectations based on North American and European soils. Without counter measures, cesium-137 produces 96% of the estimated dose for returning residents, mostly through uptake from the soil to terrestrial food crops but also from external gamma exposure. The doses are calculated assuming a resettlement date of 1999. The estimated maximum annual effective dose for current island conditions is 4.0 mSv when imported foods, which are now an established part of the diet, are available. The corresponding 30-, 50-, and 70-y integral effective doses are 9.1 cSv, 13 cSv, and 15 cSv, respectively. A corresponding uncertainty analysis showed that after about 5 y of residence, the 95% confidence limits on population-average dose would be ±35% of its expected value. We have evaluated various countermeasures to reduce 137 Cs in food crops. Treatment with potassium reduces the uptake of 137 Cs into food crops, and therefore the ingestion dose, to about 5% of pretreatment levels and has essentially no negative environmental consequences

  14. Radiation dose reduction for CT assessment of urolithiasis using iterative reconstruction. A prospective intra-individual study

    Energy Technology Data Exchange (ETDEWEB)

    Harder, Annemarie M. den; Willemink, Martin J.; Wessels, Frank J.; Schilham, Arnold M.R.; Leiner, Tim; Jong, Pim A. de [Utrecht University Medical Center, Department of Radiology, Utrecht (Netherlands); Doormaal, Pieter J. van; Budde, Ricardo P.J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Lock, M.T.W.T. [University Medical Center, Department of Urology, Utrecht (Netherlands)

    2018-01-15

    To assess the performance of hybrid (HIR) and model-based iterative reconstruction (MIR) in patients with urolithiasis at reduced-dose computed tomography (CT). Twenty patients scheduled for unenhanced abdominal CT for follow-up of urolithiasis were prospectively included. Routine dose acquisition was followed by three low-dose acquisitions at 40%, 60% and 80% reduced doses. All images were reconstructed with filtered back projection (FBP), HIR and MIR. Urolithiasis detection rates, gall bladder, appendix and rectosigmoid evaluation and overall subjective image quality were evaluated by two observers. 74 stones were present in 17 patients. Half the stones were not detected on FBP at the lowest dose level, but this improved with MIR to a sensitivity of 100%. HIR resulted in a slight decrease in sensitivity at the lowest dose to 72%, but outperformed FBP. Evaluation of other structures with HIR at 40% and with MIR at 60% dose reductions was comparable to FBP at routine dose, but 80% dose reduction resulted in non-evaluable images. CT radiation dose for urolithiasis detection can be safely reduced by 40 (HIR)-60 (MIR) % without affecting assessment of urolithiasis, possible extra-urinary tract pathology or overall image quality. (orig.)

  15. Assessment of Effective Dose Equivalent of Indoor 222Rn Daughters in Inchass

    International Nuclear Information System (INIS)

    Ali, E.M.; Taha, T.M.; Gomaa, M.A.; El-Hussein, A.M.; Ahmad, A.A.

    2000-01-01

    The dominant component of natural radiation dose for the general population comes from the radon gas 222 Rn and its short-lived decay products, Ra A ( 214 Po), Ra B ( 214 Pb), Ra C ( 214 Bi), Ra C( 214 Po) in the breathing air. The objective of the present work is to assess the affective dose equivalent of the inhalation exposure of indoor 222 Rn for occupational workers. Average indon concentrations (Bqm -3 ) were monitored in several departments in Nuclear Research Center by radon monitor. We have calculated the lung dose equivalent and the effective dose equivalent for the Egyptian workers due to inhalation exposure of an equilibrium equivalent concentrations of radon daughters which varies from 0.27 to 2.5 mSvy -1 and 0.016 to 0.152mSvy -1 respectively. The annual effective doses obtained are within the accepted range of ICRP recommendations

  16. Advancing Dose-Response Assessment Methods for Environmental Regulatory Impact Analysis: A Bayesian Belief Network Approach Applied to Inorganic Arsenic.

    Science.gov (United States)

    Zabinski, Joseph W; Garcia-Vargas, Gonzalo; Rubio-Andrade, Marisela; Fry, Rebecca C; Gibson, Jacqueline MacDonald

    2016-05-10

    Dose-response functions used in regulatory risk assessment are based on studies of whole organisms and fail to incorporate genetic and metabolomic data. Bayesian belief networks (BBNs) could provide a powerful framework for incorporating such data, but no prior research has examined this possibility. To address this gap, we develop a BBN-based model predicting birthweight at gestational age from arsenic exposure via drinking water and maternal metabolic indicators using a cohort of 200 pregnant women from an arsenic-endemic region of Mexico. We compare BBN predictions to those of prevailing slope-factor and reference-dose approaches. The BBN outperforms prevailing approaches in balancing false-positive and false-negative rates. Whereas the slope-factor approach had 2% sensitivity and 99% specificity and the reference-dose approach had 100% sensitivity and 0% specificity, the BBN's sensitivity and specificity were 71% and 30%, respectively. BBNs offer a promising opportunity to advance health risk assessment by incorporating modern genetic and metabolomic data.

  17. Comparison of the regulatory models assessing off-site radiological dose due to the routine releases of tritium

    International Nuclear Information System (INIS)

    Hwang, W. T.; Kim, E. H.; Han, M. H.; Choi, Y. H.; Lee, H. S.; Lee, C. W.

    2005-01-01

    Methodologies of NEWTRIT model, NRC model and AIRDOS-EPA model, which are off-site dose assessment models for regulatory compliance from routine releases of tritium into the environment, were investigated. Using the domestic data, if available, the predictive results of the models were compared. Among them, recently developed NEWTRIT model considers only doses from organically bounded tritium (OBT) due to environmental releases of tritiated water (HTO). A total dose from all exposure pathways predicted from AIRDOS-EPA model was 1.03 and 2.46 times higher than that from NEWTRIT model and NRC model, respectively. From above result, readers should not have an understanding that a predictive dose from NRC model may be underestimated compared with a realistic dose. It is because of that both mathematical models and corresponding parameter values for regulatory compliance are based on the conservative assumptions. For a dose by food consumption predicted from NEWTRIT model, the contribution of OBT was nearly equivalent to that of HTO due to relatively high consumption of grains in Korean. Although a total dose predicted from NEWTRIT model is similar to that from AIRDOS-EPA model, NEWTRIT model may be have a meaning in the understanding of phenomena for the behavior of HTO released into the environment

  18. Development of a methodology for assessing the environmental impact of radioactivity in Northern Marine environments

    International Nuclear Information System (INIS)

    Brown, J.E.; Hosseini, A.; Borretzen, P.; Thorring, H. . E-mail havard.thorring@nrpa.no

    2006-01-01

    The requirement to assess the impacts of radioactivity in the environment explicitly and transparently is now generally accepted by the scientific community. A recently developed methodology for achieving this end for marine ecosystems is presented within this paper. With its clear relationship to an overarching system, the marine impact assessment is built around components of environmental transfer, ecodosimetry and radiobiological effects appraisal relying on the use of 'reference organisms'. Concentration factors (CFs), dynamic models and, in cases where parameters are missing, allometry have been employed in the consideration of radionuclide transfer. Dose conversion coefficients (DCCs) have been derived for selected flora and fauna using, inter alia, dose attenuation and chord distribution functions. The calculated dose-rates can be contextualised through comparison with dose-rates arising from natural background and chronic dose-rates at which biological effects have been observed in selected 'umbrella' endpoints

  19. ARN Training on Advance Methods for Internal Dose Assessment: Application of Ideas Guidelines

    International Nuclear Information System (INIS)

    Rojo, A.M.; Gomez Parada, I.; Puerta Yepes, N.; Gossio, S.

    2010-01-01

    Dose assessment in case of internal exposure involves the estimation of committed effective dose based on the interpretation of bioassay measurement, and the assumptions of hypotheses on the characteristics of the radioactive material and the time pattern and the pathway of intake. The IDEAS Guidelines provide a method to harmonize dose evaluations using criteria and flow chart procedures to be followed step by step. The EURADOS Working Group 7 'Internal Dosimetry', in collaboration with IAEA and Czech Technical University (CTU) in Prague, promoted the 'EURADOS/IAEA Regional Training Course on Advanced Methods for Internal Dose Assessment: Application of IDEAS Guidelines' to broaden and encourage the use of IDEAS Guidelines, which took place in Prague (Czech Republic) from 2-6 February 2009. The ARN identified the relevance of this training and asked for a place for participating on this activity. After that, the first training course in Argentina took place from 24-28 August for training local internal dosimetry experts. This paper resumes the main characteristics of this activity. (authors) [es

  20. The relative importance of ingestion for multiple pathway dose assessments

    International Nuclear Information System (INIS)

    Wicker, W.; Grogan, H.; Bergstroem, U.; Hoffman, O.

    1991-01-01

    The general purpose of this report is to examine the relative importance of ingestion pathways, and particularly food chain transport in overall dose assessment. The importance of ingestion pathways is examined for various release scenarios and radionuclides because the findings are expected to differ with circumstances. The degree to which contaminated food products contribute to the total dose will affect the importance of accuracy and uncertainty of food chain model predictions, which is the main thrust of the Biospheric Model Validation Study (BIOMOVS). This analysis requires that all modes of radiation exposure be examined, including inhalation, external exposure, and the various ingestion pathways. (2 figs., 2 tabs.)

  1. The development of wireless radiation dose monitoring using smart phone

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Woo; Jeong, Gyo Seong; Lee, Yun Jong [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Kim, Chong Yeal [Chonbuk National University, Jeonju (Korea, Republic of); Lim, Chai Wan [REMTECH, Seoul (Korea, Republic of)

    2016-11-15

    Radiation workers at a nuclear facility or radiation working area should hold personal dosimeters. some types of dosimeters have functions to generate audible or visible alarms to radiation workers. However, such devices used in radiation fields these days have no functions to communicate with other equipment or the responsible personnel. our project aims at the development of a remote wireless radiation dose monitoring system that can be utilized to monitor the radiation dose for radiation workers and to notify the radiation protection manager of the dose information in real time. We use a commercial survey meter for personal radiation measurement and a smart phone for a mobile wireless communication tool and a Beacon for position detection of radiation workers using Blue tooth communication. In this report, the developed wireless dose monitoring of cellular phone is introduced.

  2. Assessment of Dose to the Nursing Infant from Radionuclides in Breast Milk

    Energy Technology Data Exchange (ETDEWEB)

    Leggett, Richard Wayne [ORNL; Eckerman, Keith F [ORNL

    2010-03-01

    A computer software package was developed to predict tissue doses to an infant due to intake of radionuclides in breast milk based on bioassay measurements and exposure data for the mother. The package is intended mainly to aid in decisions regarding the safety of breast feeding by a mother who has been acutely exposed to a radionuclide during lactation or pregnancy, but it may be applied to previous intakes during the mother s adult life. The package includes biokinetic and dosimetric information needed to address intake of Co-60, Sr-90, Cs-134, Cs-137, Ir-192, Pu-238, Pu-239, Am-241, or Cf-252 by the mother. It has been designed so that the library of biokinetic and dosimetric files can be expanded to address a more comprehensive set of radionuclides without modifying the basic computational module. The methods and models build on the approach used in Publication 95 of the International Commission on Radiological Protection (ICRP 2004), Doses to Infants from Ingestion of Radionuclides in Mothers Milk . The software package allows input of case-specific information or judgments such as chemical form or particle size of an inhaled aerosol. The package is expected to be more suitable than ICRP Publication 95 for dose assessment for real events or realistic planning scenarios in which measurements of the mother s excretion or body burden are available.

  3. The importance of triggering dose and conditions of split dose incubation to the development of thermotolerance

    International Nuclear Information System (INIS)

    Chang, P.Y.; Blakely, E.A.

    1987-01-01

    We have observed a lack of development of thermotolerance in CHO-TSH1, a protein synthetic mutant hamster cell line, under continuous heat stress treatments of 41.5 0 C, 42 0 C, and 42.5 0 C. The parental CHO-SC1 line develops thermotolerance under similar conditions. During the past year we have further examined this phenomenon in the mutant by studying the role of the level of the triggering heat dose and the time of administration to the ultimate development of thermotolerance. By increasing the temperature of the triggering dose for a brief interval, followed by the time at the permissive temperature, we were able to induce the development of thermotolerance in the protein-synthetic mutant cell. 4 refs., 2 figs

  4. Assessment of female breast dose for thoracic cone-beam CT using MOSFET dosimeters.

    Science.gov (United States)

    Sun, Wenzhao; Wang, Bin; Qiu, Bo; Liang, Jian; Xie, Weihao; Deng, Xiaowu; Qi, Zhenyu

    2017-03-21

    To assess the breast dose during a routine thoracic cone-beam CT (CBCT) check with the efforts to explore the possible dose reduction strategy. Metal oxide semiconductor field-effect transistor (MOSFET) dosimeters were used to measure breast surface doses during a thorax kV CBCT scan in an anthropomorphic phantom. Breast doses for different scanning protocols and breast sizes were compared. Dose reduction was attempted by using partial arc CBCT scan with bowtie filter. The impact of this dose reduction strategy on image registration accuracy was investigated. The average breast surface doses were 20.02 mGy and 11.65 mGy for thoracic CBCT without filtration and with filtration, respectively. This indicates a dose reduction of 41.8% by use of bowtie filter. It was found 220° partial arc scanning significantly reduced the dose to contralateral breast (44.4% lower than ipsilateral breast), while the image registration accuracy was not compromised. Breast dose reduction can be achieved by using ipsilateral 220° partial arc scan with bowtie filter. This strategy also provides sufficient image quality for thorax image registration in daily patient positioning verification.

  5. Granulometric determinations and inhalation dose assessment for atmospheric aerosol contaminated by 137Cs

    International Nuclear Information System (INIS)

    Castellani, C.M.; Luciani, A.; Oliviero, L.; Donato, R.

    1996-07-01

    During the redevelopment of Brescia freight-yard a measurement campaign of atmospheric aerosol was carried out: in fact a 137 Cs ground contamination, caused by the permanence of wagons carrying iron materials contaminated by this radionuclide, had been found out. During the redevelopment phases of excavation and can filling the workers were exposed to the danger of radioactive aerosol inhalation. The aim of the measurement campaign was to test the aerosol sampling and granulometric analysis methodologies with their sensitivity related to the inhalation dose assessments. The results of both aerosuspended mass and activity, evaluated by means of a portable cascade impactor, are presented. The granulometries have been interpolated with a log normal distribution using an iterative routine minimizing the square deviation between the calculated and experimental data. The results related to the dose assessments are also presented. These evaluations have been carried out using both the granulometric information obtained and the more recent models (ICRP 66) both the total concentration data and the dose coefficients referring to the standard conditions of ICRP 68 and of the Italian law (D.Lgs. 230/95). Furthermore the significance and the reliability of the dose assessments referring to the different methodologies are discussed, also in relation to the possibility of using this sampling methodologies for other radionuclides and different exposure conditions

  6. Dose response models and a quantitative microbial risk assessment framework for the Mycobacterium avium complex that account for recent developments in molecular biology, taxonomy, and epidemiology.

    Science.gov (United States)

    Hamilton, Kerry A; Weir, Mark H; Haas, Charles N

    2017-02-01

    Mycobacterium avium complex (MAC) is a group of environmentally-transmitted pathogens of great public health importance. This group is known to be harbored, amplified, and selected for more human-virulent characteristics by amoeba species in aquatic biofilms. However, a quantitative microbial risk assessment (QMRA) has not been performed due to the lack of dose response models resulting from significant heterogeneity within even a single species or subspecies of MAC, as well as the range of human susceptibilities to mycobacterial disease. The primary human-relevant species and subspecies responsible for the majority of the human disease burden and present in drinking water, biofilms, and soil are M. avium subsp. hominissuis, M. intracellulare, and M. chimaera. A critical review of the published literature identified important health endpoints, exposure routes, and susceptible populations for MAC risk assessment. In addition, data sets for quantitative dose-response functions were extracted from published in vivo animal dosing experiments. As a result, seven new exponential dose response models for human-relevant species of MAC with endpoints of lung lesions, death, disseminated infection, liver infection, and lymph node lesions are proposed. Although current physical and biochemical tests used in clinical settings do not differentiate between M. avium and M. intracellulare, differentiating between environmental species and subspecies of the MAC can aid in the assessment of health risks and control of MAC sources. A framework is proposed for incorporating the proposed dose response models into susceptible population- and exposure route-specific QMRA models. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. "The Dose Makes the Poison": Informing Consumers About the Scientific Risk Assessment of Food Additives.

    Science.gov (United States)

    Bearth, Angela; Cousin, Marie-Eve; Siegrist, Michael

    2016-01-01

    Intensive risk assessment is required before the approval of food additives. During this process, based on the toxicological principle of "the dose makes the poison,ˮ maximum usage doses are assessed. However, most consumers are not aware of these efforts to ensure the safety of food additives and are therefore sceptical, even though food additives bring certain benefits to consumers. This study investigated the effect of a short video, which explains the scientific risk assessment and regulation of food additives, on consumers' perceptions and acceptance of food additives. The primary goal of this study was to inform consumers and enable them to construct their own risk-benefit assessment and make informed decisions about food additives. The secondary goal was to investigate whether people have different perceptions of food additives of artificial (i.e., aspartame) or natural origin (i.e., steviolglycoside). To attain these research goals, an online experiment was conducted on 185 Swiss consumers. Participants were randomly assigned to either the experimental group, which was shown a video about the scientific risk assessment of food additives, or the control group, which was shown a video about a topic irrelevant to the study. After watching the video, the respondents knew significantly more, expressed more positive thoughts and feelings, had less risk perception, and more acceptance than prior to watching the video. Thus, it appears that informing consumers about complex food safety topics, such as the scientific risk assessment of food additives, is possible, and using a carefully developed information video is a successful strategy for informing consumers. © 2015 Society for Risk Analysis.

  8. ACUTRI: a computer code for assessing doses to the general public due to acute tritium releases

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Sumi; Noguchi, Hiroshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Ryufuku, Susumu; Sasaki, Toshihisa; Kurosawa, Naohiro [Visible Information Center, Inc., Tokai, Ibaraki (Japan)

    2002-11-01

    Tritium, which is used as a fuel of a D-T burning fusion reactor, is the most important radionuclide for the safety assessment of a nuclear fusion experimental reactor such as ITER. Thus, a computer code, ACUTRI, which calculates the radiological impact of tritium released accidentally to the atmosphere, has been developed, aiming to be of use in a discussion of licensing of a fusion experimental reactor and an environmental safety evaluation method in Japan. ACUTRI calculates an individual tritium dose based on transfer models specific to tritium in the environment and ICRP dose models. In this calculation it is also possible to analyze statistically on meteorology in the same way as a conventional dose assessment method according to the meteorological guide of the Nuclear Safety Commission of Japan. A Gaussian plume model is used for calculating the atmospheric dispersion of tritium gas (HT) and/or tritiated water (HTO). The environmental pathway model in ACUTRI considers the following internal exposures: inhalation from a primary plume (HT and/or HTO) released from the facilities and inhalation from a secondary plume (HTO) reemitted from the ground following deposition of HT and HTO. This report describes an outline of the ACUTRI code, a user guide and the results of test calculation. (author)

  9. Prenatal radiation doses from radiopharmaceuticals

    International Nuclear Information System (INIS)

    Rojo, A.M.; Gomez Parada, I.M.; Di Trano, J.L.

    1998-01-01

    The radiopharmaceutical administration with diagnostic or therapeutic purpose during pregnancy implies a prenatal radiation dose. The dose assessment and the evaluation of the radiological risks become relevant due to the great radiosensitivity of the fetal tissues in development. This paper is a revision of the available data for estimating fetal doses in the cases of the more frequently used radiopharmaceuticals in nuclear medicine, taking into account recent investigation in placental crossover. The more frequent diagnostic and therapeutic procedures were analyzed according to the radiation doses implied. (author) [es

  10. Dose reconstruction modeling for medical radiation workers

    International Nuclear Information System (INIS)

    Choi, Yeong Chull; Cha, Eun Shil; Lee, Won Jin

    2017-01-01

    Exposure information is a crucial element for the assessment of health risk due to radiation. Radiation doses received by medical radiation workers have been collected and maintained by public registry since 1996. Since exposure levels in the remote past are greater concern, it is essential to reconstruct unmeasured doses in the past using known information. We developed retrodiction models for different groups of medical radiation workers and estimate individual past doses before 1996. Reconstruction models for past radiation doses received by medical radiation workers were developed, and the past doses were estimated. Using these estimates, organ doses should be calculated which, in turn, will be used to explore a wide range of health risks of medical occupational radiation exposure. Reconstruction models for past radiation doses received by medical radiation workers were developed, and the past doses were estimated. Using these estimates, organ doses should be calculated which, in turn, will be used to explore a wide range of health risks of medical occupational radiation exposure.

  11. Dose reconstruction modeling for medical radiation workers

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yeong Chull; Cha, Eun Shil; Lee, Won Jin [Dept. of Preventive Medicine, Korea University, Seoul (Korea, Republic of)

    2017-04-15

    Exposure information is a crucial element for the assessment of health risk due to radiation. Radiation doses received by medical radiation workers have been collected and maintained by public registry since 1996. Since exposure levels in the remote past are greater concern, it is essential to reconstruct unmeasured doses in the past using known information. We developed retrodiction models for different groups of medical radiation workers and estimate individual past doses before 1996. Reconstruction models for past radiation doses received by medical radiation workers were developed, and the past doses were estimated. Using these estimates, organ doses should be calculated which, in turn, will be used to explore a wide range of health risks of medical occupational radiation exposure. Reconstruction models for past radiation doses received by medical radiation workers were developed, and the past doses were estimated. Using these estimates, organ doses should be calculated which, in turn, will be used to explore a wide range of health risks of medical occupational radiation exposure.

  12. Development of a computational code for the internal doses assessment of the main radionuclides of occupational exposure at IPEN; Desenvolvimento de um codigo computacional de apoio ao calculo de dose interna para radionuclideos de interesse do IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Claro, Thiago Ribeiro

    2011-07-01

    The dose resulting from internal contamination can be estimated with the use of biokinetic models combined with experimental results obtained from bioanalysis and assessment of the time of incorporation. The biokinetics models are represented by a set of compartments expressing the transportation, retention and elimination of radionuclides from the body. The ICRP publications, number 66, 78 and 100, present compartmental models for the respiratory tract, gastrointestinal tract and for systemic distribution for an array of radionuclides of interest for the radiological protection. The objective of this work is to develop a computational code for the internal doses assessment of the main radionuclides of occupational exposure at IPEN. Consequently serving as a agile and efficient tool for the designing, visualization and resolution of compartmental models of any nature. The architecture of the system was conceived containing two independent software: CBT - responsible for the setup and manipulation of models and SSID - responsible for the mathematical solution of the models. Four different techniques are offered for the resolution of system of equations, including semi-analytical and numerical methods, allowing for comparison of precision and performance of both. The software was developed in C{ne} programming, using a Microsoft Access database and XML standards for file exchange with other applications. Compartmental models for uranium, thorium and iodine radionuclides were generated for the validation of the CBT software. The models were subsequently solved via SSID software and the results compared with the values published in the issue 78 of ICRP. In all cases the system replicated the values published by ICRP. (author)

  13. OSL signal of IC chips from mobile phones for dose assessment in accidental dosimetry

    International Nuclear Information System (INIS)

    Mrozik, A.; Marczewska, B.; Bilski, P.; Książek, M.

    2017-01-01

    The rapid assessment of the radiation dose is very important for the prediction of biological effects after unintended exposition. The materials for use as dosimeters in accidental dosimetry should be everyday objects which are usually placed near the human body, for example mobile phones. IC (Integrated Circuit) chip is one of several electronic components of mobile phones which give a luminescent signal. The measurements of samples from different mobile phones and smartphones were conducted by optically stimulated luminescence (OSL) and thermoluminescence (TL) methods. The OSL measurement was performed in two ways: with readouts at room temperature and at 100 °C. This work is focused on determination of OSL dose response of IC chips, minimum detectable dose (MDD), OSL signal stability in the time after the exposition, its repeatability and sensitivity to light. Several tests of the assessment of unknown doses were also conducted. The readouts at 100 °C indicate the reducing of the fading of OSL signal in the first hours after irradiation in comparison with room temperature readouts. The obtained results showed relatively good dosimetric properties of IC chips: their high sensitivity to the ionizing radiation, linear dose response up to 10 Gy and a good reproducibility of OSL signal which can allow the dose recovery of doses less than 2 Gy in 14 days after an incident with the accuracy better than 25%. The fading is a drawback of IC chips and the fading factor should be considered when calculating the dose. - Highlights: • IC chips from smartphones demonstrated high potential for accidental dosimetry. • Minimum detectable dose was estimated as a value of 50 mGy. • Samples showed linear dose response for the dose range from 0.05 Gy up to 10 Gy.

  14. Dose assessment in patients undergoing lung examinations by computed tomography

    International Nuclear Information System (INIS)

    Gonzaga, Natalia B.; Silva, Teogenes A. da; Magalhaes, Marcos J.

    2011-01-01

    In the last fifteen years, the use of computed tomography (CT) has increased alongside other radiology technologies technologies. Its contribution has already achieved 34% in terms of doses undergone by patients. Radiation protection of patients submitted to CT examinations is based on the knowledge of internationally defined dosimetric quantities as the CT air kerma-length product (P K,L ) and weighted CT air kerma index (C w ). In Brazil, those dosimetric quantities are not routinely used and the optimization criteria are based only upon the MSAD - the average dose in multislices. In this work, the dosimetric quantities P K,L and C w were assessed by the CT Expo program for seven protocols used daily for lung examinations in adults with the use of Siemens and Philips scanners in Belo Horizonte. Results showed that P K,L values varied from 163 to 558 mGy.cm and the C w from 9.6 to 17.5 mGy. All results were found to be lower than the reference values internationally recommended by ICRP 87 and the European Community 16262 (30 mGy and 650 mGy.cm). The large dose ranges suggest that optimization of patient dose reduction is still possible without losses in the image quality and new reference dose levels could be recommended after a large survey to be carried out in the region. (author)

  15. Dose assessment in pediatric computerized tomography

    International Nuclear Information System (INIS)

    Vilarinho, Luisa Maria Auredine Lima

    2004-01-01

    The objective of this work was the evaluation of radiation doses in paediatric computed tomography scans, considering the high doses usually involved and the absence of any previous evaluation in Brazil. Dose values were determined for skull and abdomen examinations, for different age ranges, by using the radiographic techniques routinely used in the clinical centers investigated. Measurements were done using pencil shape ionization chambers inserted in polymethylmethacrylate (PMMA) phantoms. These were compact phantoms of different diameters were specially designed and constructed for this work, which simulate different age ranges. Comparison of results with published values showed that doses were lower than the diagnostic reference levels established to adults exams by the European Commission. Nevertheless, doses in paediatric phantoms were higher than those obtained in adult phantoms. The paediatric dose values obtained in Hospitals A and B were lower than the reference level (DRL) adopted by SHIMPTON for different age ranges. In the range 0 - 0.5 year (neonatal), the values of DLP in Hospital B were 94 por cent superior to the DRL For the 10 years old children the values of CTDI w obtained were inferior in 89 por cent for skull and 83 por cent for abdomen examinations, compared to the values published by SHRIMPTON and WALL. Our measured CTDI w values were inferior to the values presented for SHRIMPTON and HUDA, for all the age ranges and types of examinations. It was observed that the normalized dose descriptors values in children in the neonatal range were always superior to the values of doses for the adult patient. In abdomen examinations, the difference was approximately 90% for the effective dose (E) and of 57%.for CTDI w . (author)

  16. General guidelines for the assessment of internal dose from monitoring data: Progress of the IDEAS project

    International Nuclear Information System (INIS)

    Doerfel, H.; Andrasi, A.; Bailey, M.; Blanchardon, E.; Cruz-Suarez, R.; Berkovski, V.; Castellani, C. M.; Hurtgenv, C.; Leguen, B.; Malatova, I.; Marsh, J.; Stather, J.; Zeger, J.

    2007-01-01

    In recent major international intercomparison exercises on intake and internal dose assessments from monitoring data, the results calculated by different participants varied significantly. Based on this experience the need for harmonisation of the procedures has been formulated within an EU 5. Framework Programme research project. The aim of the project, IDEAS, is to develop general guidelines for standardising assessments of intakes and internal doses. The IDEAS project started in October 2001 and ended in June 2005. The project is closely related to some goals of the work of Committee 2 of the ICRP and since 2003 there has been close cooperation between the two groups. To ensure that the guidelines are applicable to a wide range of practical situations, the first step was to compile a database of well-documented cases of internal contamination. In parallel, an improved version of an existing software package was developed and distributed to the partners for further use. A large number of cases from the database was evaluated independently by the partners and the results reviewed. Based on these evaluations, guidelines were drafted and discussed with dosimetry professionals from around the world by means of a virtual workshop on the Internet early in 2004. The guidelines have been revised and refined on the basis of the experiences and discussions in this virtual workshop. The general philosophy of the Guidelines is presented here, focusing on the principles of harmonisation, optimisation and proportionality. Finally, the proposed Levels of Task to structure the approach of internal dose evaluation are reported. (authors)

  17. Patient dose in image guided radiotherapy: Monte Carlo study of the CBCT dose contribution

    OpenAIRE

    Leotta, Salvatore; Amato, Ernesto; Settineri, Nicola; Basile, Emilia; Italiano, Antonio; Auditore, Lucrezia; Santacaterina, Anna; Pergolizzi, Stefano

    2018-01-01

    Image Guided RadioTherapy (IGRT) is a technique whose diffusion is growing thanks to the well-recognized gain in accuracy of dose delivery. However, multiple Cone Beam Computed Tomography (CBCT) scans add dose to patients, and its contribution has to be assessed and minimized. Aim of our work was to evaluate, through Monte Carlo simulations, organ doses in IGRT due to CBCT and therapeutic MV irradiation in head-neck, thorax and pelvis districts. We developed a Monte Carlo simulation in GAMOS ...

  18. MCNP Code in Assessment of Variations of Effective Dose with Torso Adipose Tissue Thickness

    International Nuclear Information System (INIS)

    Massoud, E.

    2005-01-01

    The effective dose is the unite used in the field of radiation protection. It is a well defined doubly weighted uantity involving both physical and biological variables. Several factors may induce variation in the effective dose in different individuals of similar exposure data. One of these factors is the variation of adipose tissue thickness in different exposed individuals. This study essentially concenrs the assessment of the possible variation in the effective dose due to variation in the thickness of adipose tissue. The study was done using MCNP4b code to perform mathematical model of the human body depending on that given to the reference man developed by International Commission of Radiological Protection (ICRP), and calculate the effective dose with different thicknessess of adipose tissues. The study includes a comprehensive appraisal of the Monte Cario simulation, the Medical Internal Radiation Dose (MIRD) model for the human body, and the various mathematical considerations involved in the radiation dose calculations for the various pertinent parts of the human body. The radiation energies considered were 80 KeV, 300 KeV and I MeV, applying two exposure positions; anteroposterior (AP), postero-anterior (PA) with different adipose tissue thickness. This study is a theoretical approach based on detailed mathematical calculations of great precision that deals with all considerations involved in the mechanisms of radiation energy absorption in biological system depending on the variation in the densities of the particular in biological system depending on the variation in the densities of the particular tissues. The results obtained indicate that maximum decrease in effective dose occures with the lowest energy at 5cm adipose tissues thickeness for both AP and PA exposure positions. The results obtained were compared to similar work previsouly done using MCNP4 b showing very good agreement

  19. Radioactivity Risk Assessment of Radon and Gamma Dose at One Uranium Tailings Pond in China

    Science.gov (United States)

    Lou, Yalong; Liu, Yong; Peng, Guowen; Zhao, Guodong; Zhang, Yan; Yang, Zhu

    2018-01-01

    A year-long monitoring of gamma radiation effective dose rate and radon concentration had been done in the reservoir area of one uranium tailings pond in Hunan province (The monitoring area included indoor and outdoor area of residential buildings and workshops, tailings dam slope). Afterwards, the annual effective radiation dose of the people in that radiation environment had been calculated based on the results of monitoring, as well as a radiation risk assessment. According to the assessment, gamma radiation effective dose rate and radon concentration in the monitoring area were low, and the annual effective radiation dose was far below the international standard (30mSv), which showed that the radiation would not put the people’s health at risk. However, the annual effective radiation dose of gamma was far above that of radon in the area of uranium tailings pond; therefore, it’s advisable to take quarantine measures in in the area of uranium tailings pond to keep the surrounding residents away from unnecessary ionizing radiation.

  20. Phantoms for quality control procedures in digital breast tomosynthesis: dose assessment

    NARCIS (Netherlands)

    Bouwman, R. W.; Diaz, O.; van Engen, R. E.; Young, K. C.; den Heeten, G. J.; Broeders, M. J. M.; Veldkamp, W. J. H.; Dance, D. R.

    2013-01-01

    The recent introduction of digital breast tomosynthesis into clinical practice requires quality control procedures. In this study we have investigated whether the assessment of the average glandular dose for modelled standard breasts can be performed using a combination of polymethyl methacrylate

  1. ARN Training Course on Advance Methods for Internal Dose Assessment: Application of Ideas Guidelines

    International Nuclear Information System (INIS)

    Rojo, A.M.; Gomez Parada, I.; Puerta Yepes, N.; Gossio, S.

    2010-01-01

    Dose assessment in case of internal exposure involves the estimation of committed effective dose based on the interpretation of bioassay measurement, and the assumptions of hypotheses on the characteristics of the radioactive material and the time pattern and the pathway of intake. The IDEAS Guidelines provide a method to harmonize dose evaluations using criteria and flow chart procedures to be followed step by step. The EURADOS Working Group 7 'Internal Dosimetry', in collaboration with IAEA and Czech Technical University (CTU) in Prague, promoted the 'EURADOS/IAEA Regional Training Course on Advanced Methods for Internal Dose Assessment: Application of IDEAS Guidelines' to broaden and encourage the use of IDEAS Guidelines, which took place in Prague (Czech Republic) from 2-6 February 2009. The ARN identified the relevance of this training and asked for a place for participating on this activity. After that, the first training course in Argentina took place from 24-28 August for training local internal dosimetry experts. (authors)

  2. Assessment at the 66. day of projected external doses for populations living in the North-West fallout zone of the Fukushima nuclear accident. Impact of population evacuation measures

    International Nuclear Information System (INIS)

    2011-01-01

    This document reports a dose assessment study performed by the IRSN (the French Radioprotection and Safety Nuclear Institute) 66 days after the Fukushima nuclear accident. A new dose assessment was carried out by IRSN to estimate projected doses due to external exposure from radioactive deposits, for exposure durations of 3 months, 1 year and 4 years before evacuation. The purpose of this report is to provide insight on all radiological assessments performed to the knowledge of the IRSN (the French Radioprotection and Safety Nuclear Institute) to date and the impact of population evacuation measures to be taken to minimize the medium and long-term risks of developing leukaemia or other radiation-induced cancers. This report only considers the external doses already received as well as the doses that may be received in the future from fallout deposits, regardless of doses received previously from the radioactive plume

  3. A phantom for assessing the personal dose equivalent, H{sub P}(10); Um fantoma para a avaliacao do equivalente de dose pessoal, H{sub P}(10).

    Energy Technology Data Exchange (ETDEWEB)

    Santoro, C.; Filho, J.A [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear; Santos, M.A.P.; Filho, L.C.G., E-mail: chsantoro@gmail.com, E-mail: masantos@cnen.gov.br, E-mail: l.filho@cnen.gov.br, E-mail: jaf@ufpe.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2013-10-15

    Characteristics of a phantom designed to evaluate the personal dose equivalent, H{sub P}(10), and appropriate for photographic dosimetry are presented. It is called HP(10) phantom due to cavities constructed to insert dosimetric films at a depth of 10 mm. The H{sub P}(10) phantom is irradiated with ionizing radiation energy, E, from 45 to 1250 keV, with doses ranging from 0.2 to 50 mSv. It is positioned in the direction α = 0 °, and the radiation field focusing perpendicular to its front surface. So, are established calibration curves of dosimeters in the position conventionally true and quantities H{sub P}(10). It made a comparison between the responses obtained with the H{sub P}(10) phantom and responses obtained when using the calibration procedure recommended by ISO dosimeters. The ISO recommends getting the air kerma, Ka, for photons at test point of the radiation field by an ionization chamber. And through conversion coefficients, h{sub pK} (10; E, α), becomes the air kerma for H{sub P}(10). The ISO 4037-3 recommendation has been studied by researchers to ensure that the low energy spectral differences occur in radiation fields which are generated by various X-ray equipment, and induce changes in the percentages of conversion coefficients on the order of 10% to 90% . On the basis of the recommendations ISO, this article develops phantom able to assess the dose to the influence of scattering and absorption of radiation, its implications with respect to dosimetry, providing improvement in the assessment of doses. (author)

  4. Process-oriented dose assessment model for 14C due to releases during normal operation of a nuclear power plant

    International Nuclear Information System (INIS)

    Aquilonius, Karin; Hallberg, Bengt

    2005-01-01

    Swedish nuclear utility companies are required to assess doses due to releases of radionuclides during normal operation. In 2001, calculation methods used earlier were updated due to new authority regulations. The isotope 14 C is of special interest in dose assessments due to the role of carbon in the metabolism of all life forms. Earlier, factors expressing the ratio between concentration of 14 C in air and in various plants were used. In order to extend the possibility to take local conditions into account, a process-oriented assessment model for uptake of carbon and doses from releases of 14 C to air was developed (POM 14 C). The model uses part of Daisy which has been developed to model the turnover of carbon in crops. [Hansen, S., Jensen, H.E., Nielsen, N.E., Svendsen, H., 1993. Description of the Soil Plant System Model DAISY, Basic Principles and Modelling Approach. Simulation Model for Transformation and Transport of Energy and Matter in the Soil Plant Atmosphere System. Jordbruksfoerlaget, The Royal Veterianary and Agricultural University, Copenhagen, Denmark]. The main objectives were to test model performance of the former method, and to investigate if taking site specific parameters into account to a greater degree would lead to major differences in the results. Several exposure pathways were considered: direct consumption of locally grown cereals, vegetables, and root vegetables, as well as consumption of milk and meat from cows having eaten fodder cereals and green fodder from the area around the nuclear plant. The total dose of the earlier model was compared with that of POM 14 C. The result of the former was shown to be slightly higher than the latter, but POM 14 C confirmed that the earlier results were of a reasonable magnitude. When full account of local conditions was taken, e.g. as regards solar radiation, temperature, and concentration of 14 C in air at various places in the surroundings of each nuclear plant, a difference in dose between

  5. Low-Dose and Standard-Dose Unenhanced Helical Computed Tomography for the Assessment of Acute Renal Colic: Prospective Comparative Study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Soo; Hwang, Im Kyung; Choi, Yo Won; Namkung, Sook; Kim, Heung Cheol; Hwang, Woo Cheol; Choi, Kuk Myung; Park, Ji Kang; Han, Tae Il; Kang, Weechang [Cheju National Univ. College of Medicine, Jeju (Korea, Republic of). Dept. of Diagnostic Radiology

    2005-11-01

    Purpose: To compare the efficacy of low-dose and standard-dose computed tomography (CT) for the diagnosis of ureteral stones. Material and Methods: Unenhanced helical CT was performed with both a standard dose (260 mAs, pitch 1.5) and a low dose (50 mAs, pitch 1.5) in 121 patients suspected of having acute renal colic. The two studies were prospectively and independently interpreted for the presence and location of ureteral stones, abnormalities unrelated to stone disease, identification of secondary signs, i.e. hydronephrosis and perinephric stranding, and tissue rim sign. The standard-dose CT images were interpreted by one reviewer and the low-dose CT images independently by two reviewers unaware of the standard-dose CT findings. The findings of the standard and low-dose CT scans were compared with the exact McNemar test. Interobserver agreements were assessed with kappa analysis. The effective radiation doses resulting from two different protocols were calculated by means of commercially available software to which the Monte-Carlo phantom model was given. Results: The sensitivity, specificity, and accuracy of standard-dose CT for detecting ureteral stones were 99%, 93%, and 98%, respectively, whereas for the two reviewers the sensitivity of low-dose CT was 93% and 95%, specificity 86%, and accuracy 92% and 94%. We found no significant differences between standard-dose and low-dose CT in the sensitivity and specificity for diagnosing ureter stones ( P >0.05 for both). However, the sensitivity of low-dose CT for detection of 19 stones less than or equal to 2 mm in diameter was 79% and 68%, respectively, for the two reviewers. Low-dose CT was comparable to standard-dose CT in visualizing hydronephrosis and the tissue rim sign. Perinephric stranding was far less clear on low-dose CT. Low-dose CT had the same diagnostic performance as standard-dose CT in diagnosing alternative diseases. Interobserver agreement between the two low-dose CT reviewers in the diagnosis of

  6. Application of a simple phantom in assessing the effects of dose reduction on image quality in chest radiography

    International Nuclear Information System (INIS)

    Egbe, N.O.; Heaton, B.; Sharp, P.F.

    2010-01-01

    Purpose: Firstly, to evaluate a commercial chest phantom incorporating a quasi anthropomorphic insert by comparing exposure measurements on the phantom with those of actual patients and, secondly, to assess the value of the phantom for image quality and dose optimisation. Methods: In the first part of the study entrance surface doses (ESD), Beam transmission (BT), and optical density (OD) were obtained for 77 chest radiography patients and compared with measurements made from exposures of the phantom using the respective patient exposure factors from chest examination. Differences were assessed with a student t-test, while the Pearson's linear correlation coefficient was used to test for any linear relationship. The second part assessed the applicability of the phantom to image quality studies by investigating the effect, on the clarity and detectability of lung lesions made from gelatine, of reducing patient dose below current dose levels. Clarity of linear objects of different dimensions was also studied. Lesion detectability and clarity was assessed by four observers. The possibility of extending dose reduction below current dose levels (D ref ) was assessed from comparison of doses that produced statistically significant differences in image quality from D ref . Results: Results show that, with the exception of entrance doses and beam transmission through the diaphragm (P > 0.05), differences in OD and beam transmission between patients and phantom were statistically significant (P ref produced significant changes in both clarity and detectability. Conclusion: Within limits posed by the observed differences, the phantom can be applied to image quality studies in diagnostic radiology.

  7. Indoor aerosol modeling for assessment of exposure and respiratory tract deposited dose

    Science.gov (United States)

    Hussein, Tareq; Wierzbicka, Aneta; Löndahl, Jakob; Lazaridis, Mihalis; Hänninen, Otto

    2015-04-01

    Air pollution is one of the major environmental problems that influence people's health. Exposure to harmful particulate matter (PM) occurs both outdoors and indoors, but while people spend most of their time indoors, the indoor exposures tend to dominate. Moreover, higher PM concentrations due to indoor sources and tightness of indoor environments may substantially add to the outdoor originating exposures. Empirical and real-time assessment of human exposure is often impossible; therefore, indoor aerosol modeling (IAM) can be used as a superior method in exposure and health effects studies. This paper presents a simple approach in combining available aerosol-based modeling techniques to evaluate the real-time exposure and respiratory tract deposited dose based on particle size. Our simple approach consists of outdoor aerosol data base, IAM simulations, time-activity pattern data-base, physical-chemical properties of inhaled aerosols, and semi-empirical deposition fraction of aerosols in the respiratory tract. These modeling techniques allow the characterization of regional deposited dose in any metric: particle mass, particle number, and surface area. The first part of this presentation reviews recent advances in simple mass-balance based modeling methods that are needed in analyzing the health relevance of indoor exposures. The second part illustrates the use of IAM in the calculations of exposure and deposited dose. Contrary to previous methods, the approach presented is a real-time approach and it goes beyond the exposure assessment to provide the required information for the health risk assessment, which is the respiratory tract deposited dose. This simplified approach is foreseen to support epidemiological studies focusing on exposures originating from both indoor and outdoor sources.

  8. Low-dose effects of bisphenol A on mammary gland development in rats

    DEFF Research Database (Denmark)

    Egebjerg, Karen Mandrup; Boberg, Julie; Isling, Louise Krag

    2016-01-01

    was to perform a study robust enough to contribute to the risk assessment of BPA and to elucidate possible biphasic dose–response relationships. We investigated mammary gland effects in the offspring at 22, 100, and 400 days of age. Male offspring showed increased mammary outgrowth on pup day (PD) 22 at 0.025 mg...... intraductal hyperplasia in female rats could be associated with an increased risk for developing hyperplastic lesions, which are parallels to early signs of breast neoplasia in women. Collectively, current knowledge on effects of BPA on mammary gland at low doses indicates that highly exposed humans may...

  9. Equine scintigraphy: assessment of the dose received by the personnel; Scintigraphie equine: estimation de la dose recue par le personnel

    Energy Technology Data Exchange (ETDEWEB)

    Clairand, I.; Bottollier, J.F.; Trompier, F. [Institut de Radioprotection et de Surete Nucleaire IRSN, 92 - Fontenay aux Roses (France)

    2003-03-01

    Following a request from the Permanent Secretary of the French Commission for Artificial Radioelements (CIREA) engaged to investigate a request for a licence related to a new scintigraphy unit dedicated to equidae, a dosimetric assessment concerning the personnel attending the examination was carried out. This scintigraphy unit depends on the Goustranville Centre for Imaging and Research on the Locomotive Diseases of Equidae (CIRALE) in the Calvados region. The dosimetric assessment was carried out for the different operators during the successive stages of the scintigraphic examination. Assuming 150 examinations per year, the annual equivalent dose to the fingers skin is 150 mSv maximum for the technologist and 2 mSv for the veterinary surgeon; the annual effective dose ranges from 0.15 to 0.45 mSv, depending on the operators. (authors)

  10. Implementation of spot scanning dose optimization and dose calculation for helium ions in Hyperion

    DEFF Research Database (Denmark)

    Fuchs, Hermann; Alber, Markus; Schreiner, Thomas

    2015-01-01

    PURPOSE: Helium ions ((4)He) may supplement current particle beam therapy strategies as they possess advantages in physical dose distribution over protons. To assess potential clinical advantages, a dose calculation module accounting for relative biological effectiveness (RBE) was developed...... published so far. The advantage of (4)He seems to lie in the reduction of dose to surrounding tissue and to OARs. Nevertheless, additional biological experiments and treatment planning studies with larger patient numbers and more tumor indications are necessary to study the possible benefits of helium ion...

  11. A new method to assess the gonadal doses in women during radiation treatment

    International Nuclear Information System (INIS)

    Agrawal, M.S.; Pant, G.C.

    1977-01-01

    The relative inaccessibility of the ovaries renders direct measurement of the gonadal doses difficult. A relatively simple method is described to tackle this problem - using the upper margin of the public symphysis as a reference point. Measurement of Radiation doses were done in a Masonite human phantom using T.L.D. and a Co-60 teletherapy unit. The accompanying figures document the observations made. The distance between the lower edge of the treatment port and the reference point is denoted by 'd'. First figure relates observed ratios of the radiation doses at the ovary and the reference point to 'd' for various port sizes and the second figure shows the relationship between the area of the port and the dose ratio (ovary: reference-point) for various values of 'd'. The advantage of this documentation is that it serves as a 'Ready Reckoner' to assess the ovarian doses under different treatment situations-once the doses at the reference point is measured

  12. Radiological dose assessment related to management of naturally occurring radioactive materials generated by the petroleum industry

    International Nuclear Information System (INIS)

    Smith, K.P.; Blunt, D.L.; Williams, G.P.; Tebes, C.L.

    1995-01-01

    A preliminary radiological dose assessment related to equipment decontamination, subsurface disposal, landspreading, equipment smelting, and equipment burial was conducted to address concerns regarding the presence of naturally occurring radioactive materials in production waste streams. The assessment evaluated the relative dose of these activities and included a sensitivity analysis of certain input parameters. Future studies and potential policy actions are recommended

  13. Realistic assessment of doses to members of the public according to council directive 96/29/Euratom and common practice in Germany

    International Nuclear Information System (INIS)

    Hornung-Lauxmann, L.; Steiner, M.

    2003-01-01

    According to Article 45 of the Council Directive 96/29/Euratom competent authorities of member states are obliged to assess radiation doses to the population as a whole and to reference groups of the population as realistic as possible. In EU member states different approaches are in use, both to identify reference groups and to assess doses. In addition realistic dose assessments are in general not systematically performed. Hence, the European Commission commissioned a study on the realistic assessment of radiation doses due to radioactive discharges from nuclear installations under normal operation. Based on this study a guide including recommendations for dose assessment has been established by an Article 31 expert group, which is applicable to retrospective and prospective dose assessment as well. The most important recommendation is to use as much site-specific information as possible. Concerning the dose assessment of reference groups it is recommended to use critical groups. Critical groups comprise of persons who receive the highest effective doses because of their living habits. In the opinion of EU experts it is sufficient to take into account only the age groups of one-year-olds, ten-years-olds and adults. Exposure pathways have been sub-divided into three groups: Those, which have to be considered in any case, those, which contribute significantly to dose depending on local conditions, and those, which only insignificantly contribute to dose. It is recommended to use only models for dose assessment which are robust, appropriate, and validated against measurements. In Germany, (hypothetical) reference persons are used for the assessment of radiation exposure to the population due to radioactive discharges from nuclear installations under normal operation. They are assumed to live at the most disadvantageous location around the site and to eat foodstuff produced at the most disadvantageous locations. For this purpose models, generalized assumptions and

  14. Assessment of radiation doses to the public in areas contaminated by the Fukushima Daiichi Nuclear Power Station accident

    International Nuclear Information System (INIS)

    Takahara, Shogo; Iijima, Masashi; Shimada, Kazumasa; Kimura, Masanori; Homma, Toshimitsu

    2013-01-01

    In the areas contaminated by radioactive materials due to the Fukushima Daiichi Nuclear Power Station accident, many residents are exposed to radiation through various exposure pathways. Dose assessment is important for providing appropriate protection to the people and clarifying the impact of the accident. The aim of this study is to provide preliminary results of the assessment of radiation doses received by the inhabitants of Fukushima Prefecture. To assess the doses realistically and comprehensively, a probabilistic approach was adopted using data that reflected realistic environmental trends and lifestyle habits in Fukushima Prefecture. In the first year after the contamination, the 95th percentile of the annual effective dose received by the inhabitants evacuated from the evacuation areas and the deliberate evacuation areas was mainly in the 1-10 mSv dose band. However, the 95th percentile of the dose received by some outdoor workers and inhabitants evacuated from highly contaminated areas was in the 10-50 mSv dose band. The doses due to external exposure to deposited radionuclides were the dominant exposure pathway, and their contributions were about 90% under prevailing contamination conditions in Fukushima Prefecture. In addition, 20%-30% of the lifetime effective dose was delivered during the first year after the contamination. (author)

  15. Dose assessment of head CT examination by volume scanning with 320-area-detector

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Kobayashi, Masanao

    2009-01-01

    CT with the 320-area-detector (320-ADCT), first presented in 2007, still requires further basic studies, particularly in the field of dose assessment, as the CT has been widely spread in clinic due to its many advantages compared with the usual spiral CT. In this paper, the assessment in the title was thereby done in human phantom and a patient with suspicious acute cerebral infarction under different scanning modes (non-spiral, spiral and volume) for their comparison. Machines for 320-ADCT, and non-spiral and spiral CT were Toshiba Aquilion ONE, and Aquilion 64-MD, respectively. Scanning of the phantom and patient was individually conducted under similar conditions of tube voltage/ current, rotation time and length with the same field of view with defined nominal slice thicknesses. Alderson human body phantom in which 240 thermoluminescent dosimeters were indwelled, was used; doses were read by the thermoluminescence dosimeter (TLD) reader model 3000 (Kyokko Co.) after scanning; and effective doses were calculated with reference to ICRP publ. 102/103 equations for patient's head to be 4.2 (64-MDCT) and 6.6 (320-ADCT) mSv, which were respectively 6.4 and 5.4 mSv when estimated using the conversion coefficient and DLP (dose length product) in the texts. It was suggested that the exposure dose at the volume scanning by 320-ADCT can be reduced in the routine examination, and in the exact diagnosis, possibly increases. These doses can be reduced further by optimization of scanning conditions by additional basic investigations. (K.T.)

  16. Efficacy of reduced doses of bentazone assessed by instruments based on measurement of chlorophyll fluorescence

    Directory of Open Access Journals (Sweden)

    Vojtěch Kocurek

    2011-01-01

    Full Text Available Chlorophyll fluorescence is a type of radiation emitted by plants as unused part of energy absorbed from sunlight. Its intensity depends on many stress factors, nutrition, weather conditions etc. Methods based on chlorophyll fluorescence measurement have potential to be perspective for the assessment of herbicide efficacy, phytotoxicity or stress influence. Two fluorometers (FluorCam and handy FluorPen were used for measurements in laboratory experiments in 2007–2009. Herbicide Basagran super with active ingredient bentazone (480 g.l−1 was tested using a parameter called ‚Quantum yield of fluorescence‘ (QY in three different doses: the registered dose 2.0 l.ha−1 (100% and lower doses 1.5 l.ha−1 (75% and 1.0 l.ha−1 (50%. Treated experimental plants of redroot pigweed (Amaranthus retroflexus L. were measured in 0, 1, 2, 3, 6, 9 and 15 days after treatment and the results were compared with subjective assessment (estimation and growth parameters. The obtained results showed that the effect of bentazone measured by both devices was statistically significantly different from untreated control. We can also detect herbicide effect earlier by QY measurement than by other methods. Different doses showed significant differences 15 days after treatment for dose 2.0 l.ha−1 in comparison with both reduced doses. The subjective assessment showed significant differences in all terms of measurement (1–15 days after application except of the day of application. Regeneration of plants for which the youngest leaves were not treated by herbicide was observed for all doses. Difference of QY values between used devices was on average 0.119 (higher for FluorCam but statistically insignificant.

  17. A METHOD TO IMPROVE DOSE ASSESSMENT BY RECONSTRUCTION OF THE COMPLETE ISOTOPES INVENTORY.

    Science.gov (United States)

    Bonin, Alice; Tsilanizara, Aimé

    2017-06-01

    Radiation shielding assessments may underestimate the expected dose if some isotopes at trace level are not considered in the isotopes inventory of the shielded radioactive materials. Indeed, information about traces is not often available. Nevertheless, the activation of some minor isotopic traces may significantly contribute to the dose build-up. This paper presents a new method (Isotopes Inventory Reconstruction-IIR) estimating the concentration of the minor isotopes in the irradiated material at the beginning of the cooling period. The method requires the solution of the inverse problem describing the irradiated material's decay. In a mixture of an irradiated uranium-plutonium oxide shielded by a set-up made of stainless-steel, porous polyethylene plaster and lead methyl methacrylate, the comparison between different methods proves that the IIR-method allows better assessment of the dose than other approximate methods. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Fetal absorbed doses by radiopharmaceutical administration

    International Nuclear Information System (INIS)

    Rojo, Ana M; Gomez Parada, Ines M.; Di Trano, Jose L.

    2000-01-01

    The radiopharmaceutical administration with diagnostic or therapeutic purpose during pregnancy implies a prenatal radiation dose. The dose assessment and the evaluation of the radiological risks become relevant due to the great radiosensitivity of the fetal tissues in development. This paper is a revision of the available data for estimating fetal doses in the cases of the more frequently used radiopharmaceuticals in nuclear medicine, taking into account recent investigation in placental crossover. The more frequent diagnostic and therapeutic procedures were analyzed according to the radiation doses implied. (author)

  19. Pantex Plant Cell 12-44-1 tritium release: Re-assessment of environmental doses for 1990 to 1992

    International Nuclear Information System (INIS)

    Snyder, S.F.; Hwang, S.T.

    1994-03-01

    A release of tritium gas occurred within Cell 12-44-1 at the Pantex Plant on May 17, 1989. The release was the result of a nuclear component containment failure. This document summarizes past assessments and characterization of the release. From 1990 to 1992, the average annual dose to the offsite maximally exposed individual (MEI), re-assessed using updated methods and data, ranged from 9E-6 to 2E-4 mrem/y. Doses at this level are well below the regulatory dose limit and support the discontinuation of the distinct calculation of the MEI doses from the cell's tritium releases in future Pantex Annual Site Environmental Reports. Additional information provides guidance for the evaluation of similar releases in the future. Improved Environmental Protection Department sampling plans and assessment goals will increase the value of the data collected during future incidents

  20. Dose assessment for public by packages shipping radioactive materials hypothetically sunk on the continental shelf. Annex 3

    International Nuclear Information System (INIS)

    Tsumune, Daisuke; Suzuki, Hiroshi; Saegusa, Toshiari; Watabe, Naohito; Asano, Hiroyuki; Maruyama, Koki; Kinehara, Yoshiki

    2001-01-01

    Radioactive materials such as spent fuel (SF), PuO 2 powder, high level wastes (HLW) and fresh mixed oxide (MOX) fuel have been transported by sea between Europe and Japan. Dose assessments for public have been performed in the past when the packages shipping radioactive materials were hypothetically sunk on the continental shelf. These studies employed various conditions and methods in their assessments and the results were not always the same. In this study, the dose assessment for these packages was performed under the same conditions and by the same methods. The effective dose equivalents of radiation exposure to the public for all materials become smaller than the previous evaluations due to more realistic assumption in this study. These evaluated results are far less than the effective dose equivalent limit (1 mSv year -1 ) by the ICRP recommendation. (author)

  1. Calculating the radiological parameters used in non-human biota dose assessment tools using ERICA Tool and site-specific data

    Energy Technology Data Exchange (ETDEWEB)

    Sotiropoulou, Maria [INRASTES, NCSR ' ' Demokritos' ' , Environmental Radioactivity Laboratory, Athens (Greece); Aristotle University of Thessaloniki, Atomic and Nuclear Physics Laboratory, Thessaloniki (Greece); Florou, Heleny [INRASTES, NCSR ' ' Demokritos' ' , Environmental Radioactivity Laboratory, Athens (Greece); Kitis, Georgios [Aristotle University of Thessaloniki, Atomic and Nuclear Physics Laboratory, Thessaloniki (Greece)

    2017-11-15

    The substantial complexity in ecosystem-radionuclide interactions is difficult to be represented in terms of radiological doses. Thus, radiological dose assessment tools use typical exposure situations for generalized organisms and ecosystems. In the present study, site-specific data and radioactivity measurements of terrestrial organisms (grass and herbivore mammals) and abiotic components (soil) are provided. The retrieved data are used in combination with the ERICA Assessment Tool for calculation of radiological parameters. The process of radionuclide transfer within ecosystem components is represented using concentration ratios (CRs), while for the calculation of dose rates the dose conversion coefficient (DCC) methodology is applied. Comparative assessments are performed between the generic and assessment-specific radiological parameters and between the resulting dose rates. Significant differences were observed between CRs calculated in this study and those reported in the literature for cesium and thorium, which can easily be explained. On the other hand, CRs calculated for radium are in very good agreement with those reported in the literature. The DCCs exhibited some small differences between the reference and the assessment-specific organism due to mass differences. The differences were observed for internal and external dose rates, but they were less pronounced for total dose rates which are typically used in the assessment of radiological impact. The results of the current work can serve as a basis for further studies of the radiological parameters in environments that have not been studied yet. (orig.)

  2. Landscape dose conversion factors used in the safety assessment SR-Site

    International Nuclear Information System (INIS)

    Avila, Rodolfo; Ekstroem, Per-Anders; Aastrand, Per-Gustav

    2010-12-01

    In this report two types of Dose Conversion Factors have been derived: i) a Landscape Dose Conversion Factor (LDF) that is applicable to continuous long-term releases to the biosphere at a constant rate, and ii) a Landscape Dose Conversion Factor for pulse releases (LDF pulse) that is applicable to a radionuclide release that reaches the biosphere in a pulse within years to hundreds of years. In SR-Site these Dose Factors are multiplied with modelled release rates or pulse releases from the geosphere to obtain dose estimates used in assessment of compliance with the regulatory risk criterion. The LDFs were calculated for three different periods of the reference glacial cycle; a period of submerged conditions following the deglaciation, the temperate period, and a prolonged period of periglacial conditions. Additionally, LDFs were calculated for the global warming climate case. The LDF pulse was calculated only for temperate climate conditions. The LDF and LDF pulse can be considered as Best Estimate values, which can be used in calculations of Best Estimate values of doses to a representative individual of the most exposed group from potential releases from a future repository. A systematic analysis of the effects of system, model and parameter uncertainties on the LDFs has been carried out. This analysis has shown that the use of the derived LDF would lead to cautious or realistic dose estimates. The models and methods that were used for derivation of the LDFs and LDF pulse are also described in this report

  3. Landscape dose conversion factors used in the safety assessment SR-Site

    Energy Technology Data Exchange (ETDEWEB)

    Avila, Rodolfo; Ekstroem, Per-Anders; Aastrand, Per-Gustav (Facilia AB (Sweden))

    2010-12-15

    In this report two types of Dose Conversion Factors have been derived: i) a Landscape Dose Conversion Factor (LDF) that is applicable to continuous long-term releases to the biosphere at a constant rate, and ii) a Landscape Dose Conversion Factor for pulse releases (LDF pulse) that is applicable to a radionuclide release that reaches the biosphere in a pulse within years to hundreds of years. In SR-Site these Dose Factors are multiplied with modelled release rates or pulse releases from the geosphere to obtain dose estimates used in assessment of compliance with the regulatory risk criterion. The LDFs were calculated for three different periods of the reference glacial cycle; a period of submerged conditions following the deglaciation, the temperate period, and a prolonged period of periglacial conditions. Additionally, LDFs were calculated for the global warming climate case. The LDF pulse was calculated only for temperate climate conditions. The LDF and LDF pulse can be considered as Best Estimate values, which can be used in calculations of Best Estimate values of doses to a representative individual of the most exposed group from potential releases from a future repository. A systematic analysis of the effects of system, model and parameter uncertainties on the LDFs has been carried out. This analysis has shown that the use of the derived LDF would lead to cautious or realistic dose estimates. The models and methods that were used for derivation of the LDFs and LDF pulse are also described in this report

  4. Sex-specific effects of low-dose gestational estradiol-17β exposure on bone development in porcine offspring

    International Nuclear Information System (INIS)

    Flöter, Veronika L.; Galateanu, Gabriela; Fürst, Rainer W.; Seidlová-Wuttke, Dana; Wuttke, Wolfgang; Möstl, Erich; Hildebrandt, Thomas B.

    2016-01-01

    Highlights: • Sex-specific effects and non-monotonic dose responses were demonstrated after low-dose in utero E2 treatment in offspring. • Alterations in bone parameters were found in prepubertal male but not female offspring. • In postpubertal female offspring, cortical and total cross-sectional area were higher at the femoral midpoint. • In utero E2 treatment did neither significantly affect hormone concentrations nor puberty onset in offspring. • The results substantiate the high sensitivity of developing organisms to exogenous estrogens. - Abstract: Estrogens are important for the bone development and health. Exposure to endocrine disrupting chemicals during the early development has been shown to affect the bone phenotype later in life. Several studies have been performed in rodents, while in larger animals that are important to bridge the gap to humans there is a paucity of data. To this end, the pig as large animal model was used in the present study to assess the influence of gestational estradiol-17β (E2) exposure on the bone development of the prepubertal and adult offspring. Two low doses (0.05 and 10 μg E2/kg body weight) referring to the ‘acceptable daily intake’ (ADI) and the ‘no observed effect level’ (NOEL) as stated for humans, and a high-dose (1000 μg E2/kg body weight), respectively, were fed to the sows every day from insemination until delivery. In the male prepubertal offspring, the ADI dose group had a lower strength strain index (p = 0.002) at the proximal tibia compared to controls, which was determined by peripheral quantitative computed tomography. Prepubertal females were not significantly affected. However, there was a higher cortical cross-sectional area (CSA) (p = 0.03) and total CSA (p = 0.02) at the femur midpoint in the adult female offspring of the NOEL dose group as measured by computed tomography. These effects were independent from plasma hormone concentrations (leptin, IGF1, estrogens), which remained

  5. Development of microcontroller based instrumentation for low dose implantation

    International Nuclear Information System (INIS)

    Suresh, K.; Saravanan, K.; Panigrahi, B.K.; Nair, K.G.M.

    2011-01-01

    In experiments like ion implantation based ion track formations, the sample is implanted to low doses of the order of 10 10 ions/cm 2 , limiting the ion beam currents to be less than 1-5 x 10 -12 A. However the standard current integrators available are not sensitive to very low currents, causing an unacceptable high level of error in dose measurement. Hence a low dose implantation measurement system has been developed. It consists of a very sensitive low current preamplifier with full scale input 1nA/100pA, a standard current integrator, a microcontroller based interface circuit, which are connected to a personal computer(PC) through USB. Two types of the software are developed for the system: the microcontroller firmware using C and windows based virtual instrument programs using LabVIEW 7.0. Necessary precautions associated with pA level measurement like rigidly fastened good quality cables, low ripple DC power supply, shielding, close mounting of the preamplifier to the sample are adopted. After necessary calibrations with an ECIL make low current source, the system has been put into regular use. Design and development details, salient features are discussed in this paper. (author)

  6. Assessing image quality and dose reduction of a new x-ray computed tomography iterative reconstruction algorithm using model observers

    International Nuclear Information System (INIS)

    Tseng, Hsin-Wu; Kupinski, Matthew A.; Fan, Jiahua; Sainath, Paavana; Hsieh, Jiang

    2014-01-01

    Purpose: A number of different techniques have been developed to reduce radiation dose in x-ray computed tomography (CT) imaging. In this paper, the authors will compare task-based measures of image quality of CT images reconstructed by two algorithms: conventional filtered back projection (FBP), and a new iterative reconstruction algorithm (IR). Methods: To assess image quality, the authors used the performance of a channelized Hotelling observer acting on reconstructed image slices. The selected channels are dense difference Gaussian channels (DDOG).A body phantom and a head phantom were imaged 50 times at different dose levels to obtain the data needed to assess image quality. The phantoms consisted of uniform backgrounds with low contrast signals embedded at various locations. The tasks the observer model performed included (1) detection of a signal of known location and shape, and (2) detection and localization of a signal of known shape. The employed DDOG channels are based on the response of the human visual system. Performance was assessed using the areas under ROC curves and areas under localization ROC curves. Results: For signal known exactly (SKE) and location unknown/signal shape known tasks with circular signals of different sizes and contrasts, the authors’ task-based measures showed that a FBP equivalent image quality can be achieved at lower dose levels using the IR algorithm. For the SKE case, the range of dose reduction is 50%–67% (head phantom) and 68%–82% (body phantom). For the study of location unknown/signal shape known, the dose reduction range can be reached at 67%–75% for head phantom and 67%–77% for body phantom case. These results suggest that the IR images at lower dose settings can reach the same image quality when compared to full dose conventional FBP images. Conclusions: The work presented provides an objective way to quantitatively assess the image quality of a newly introduced CT IR algorithm. The performance of the

  7. Pulmonary disease in cystic fibrosis: assessment with chest CT at chest radiography dose levels.

    Science.gov (United States)

    Ernst, Caroline W; Basten, Ines A; Ilsen, Bart; Buls, Nico; Van Gompel, Gert; De Wachter, Elke; Nieboer, Koenraad H; Verhelle, Filip; Malfroot, Anne; Coomans, Danny; De Maeseneer, Michel; de Mey, Johan

    2014-11-01

    To investigate a computed tomographic (CT) protocol with iterative reconstruction at conventional radiography dose levels for the assessment of structural lung abnormalities in patients with cystic fibrosis ( CF cystic fibrosis ). In this institutional review board-approved study, 38 patients with CF cystic fibrosis (age range, 6-58 years; 21 patients 18 years) underwent investigative CT (at minimal exposure settings combined with iterative reconstruction) as a replacement of yearly follow-up posteroanterior chest radiography. Verbal informed consent was obtained from all patients or their parents. CT images were randomized and rated independently by two radiologists with use of the Bhalla scoring system. In addition, mosaic perfusion was evaluated. As reference, the previous available conventional chest CT scan was used. Differences in Bhalla scores were assessed with the χ(2) test and intraclass correlation coefficients ( ICC intraclass correlation coefficient s). Radiation doses for CT and radiography were assessed for adults (>18 years) and children (chest CT protocol can replace the two yearly follow-up chest radiographic examinations without major dose penalty and with similar diagnostic quality compared with conventional CT.

  8. Assessment of 226Ra age-dependent dose from water intake

    International Nuclear Information System (INIS)

    Porntepkasemsan, Boonsom; Srisuksawad, Kanitha

    2008-01-01

    The radioactivity in canal and ground waters collected in a 2-year long observation from the vicinity of the Rare Earth Research and Development Center (RRDC), Phathumthani Province, Thailand, was measured in order to determine the concentration of 226 Ra and to estimate the age-dependent effective dose to humans due to consumption. 226 Ra activities in both canal and ground waters were well below the WHO guidance level for drinking water quality of 1 Bq L -1 . The highest 226 Ra effective doses per year were found for infants and teens. However, the observed levels of calculated 226 Ra effective doses for all age groups in both canal and ground waters show satisfactory low values (less than 15 μSv yr -1 ). These values are acceptable in accordance with the WHO recommended reference dose level of 100 μSv yr -1 from water intake of 2 L day -1

  9. Radiological-dose assessments of atolls in the northern Marshall Islands

    International Nuclear Information System (INIS)

    Robison, W.L.

    1983-04-01

    The Marshall Islands in the Equatorial Pacific, specifically Enewetak and Bikini Atolls, were the site of US nuclear testing from 1946 through 1958. In 1978, the Northern Marshall Islands Radiological Survey was conducted to evaluate the radiological conditions of two islands and ten atolls downwind of the proving grounds. The survey included aerial external gamma measurements and collection of soil, terrestrial, and marine samples for radionuclide analysis to determine the radiological dose from all exposure pathways. The methods and models used to estimate doses to a population in an environment where natural processes have acted on the source-term radionuclides for nearly 30 y, data bases developed for the models, and results of the radiological dose analyses are described

  10. Assessment of radiation doses to adult patients in computed tomography procedures

    International Nuclear Information System (INIS)

    Kabashi, Kabashi Hommeda Yosif

    2015-10-01

    The purpose of this study was to assess radiation dose and estimate the effective dose in three different detectors of CT scanners (64 slices, 16 slices and dual slice) for routine CT investigation. A total of 60 patients were examined in this study. 20 patients for dual slice (10 patient for chest and 10 for abdomen, 20 patient for sixteen slices (10 for chest and 10 for abdomen ) and 20 for sixty four slices (10 for chest and 10 for abdomen). The mean dose values for CT chest for sixteen slices were DLP 152.4±56,76 mGy.cm, CTDIvo1 4.53±1.47 mGy ED 2.13±0.974 mSv, while for dual slice the mean values were DLP is 167±55,51 mGy.cm. CTDIvo1 5.02±1.41 mGy ED 2.3±0.77 mSv, while the mean dose values for sixty four slice were DLP 567±43.63 mGy.cm,CTDIvo1 15.08±0.252 ED 7.9±0.61 mSv and for CT abdomen the mean dose values for sixteen slices were DLP 306.6±43.63 mGy.cm, CTDIvo1 6.45±3.31 mGy ED 4.59±1.83 mSv, while for dual slice the mean dose values were DLP 208±78.46 mGy.cm, CTDIvo1 27±1.46 mGy ED 3.12±1.18 mSv, while for sixty four slices the mean dose values were DLP 694.6±28.44 mGy.cm, CTDIvol 121.56±0.250 mGy ED 10.42±0.43 mSv dual slice delivered the least radiation dose while 16 and 64 slice scanners delivered the highest radiation dose. CT dose optimization protocol is not implemented in all departments. (author)

  11. Preliminary dose assessment of the Chernobyl accident

    International Nuclear Information System (INIS)

    Hull, A.P.

    1987-01-01

    From the major accident at Unit 4 of the Chernobyl nuclear power station, a plume of airborne radioactive fission products was initially carried northwesterly toward Poland, thence toward Scandinavia and into Central Europe. Reports of the levels of radioactivity in a variety of media and of external radiation levels were collected in the Department of Energy's Emergency Operations Center and compiled into a data bank. Portions of these and other data which were obtained directly from published and official reports were utilized to make a preliminary assessment of the extent and magnitude of the external dose to individuals downwind from Chernobyl. Radioactive 131 I was the predominant fission product. The time of arrival of the plume and the maximum concentrations of 131 I in air, vegetation and milk and the maximum reported depositions and external radiation levels have been tabulated country by country. A large amount of the total activity in the release was apparently carried to a significant elevation. The data suggest that in areas where rainfall occurred, deposition levels were from ten to one-hundred times those observed in nearby ''dry'' locations. Sufficient spectral data were obtained to establish average release fractions and to establish a reference spectra of the other nuclides in the release. Preliminary calculations indicated that the collective dose equivalent to the population in Scandinavia and Central Europe during the first year after the Chernobyl accident would be about 8 x 10 6 person-rem. From the Soviet report, it appears that a first year population dose of about 2 x 10 7 person-rem (2 x 10 5 Sv) will be received by the population who were downwind of Chernobyl within the U.S.S.R. during the accident and its subsequent releases over the following week. 32 refs., 14 figs., 20 tabs

  12. Dose tracking and dose auditing in a comprehensive computed tomography dose-reduction program.

    Science.gov (United States)

    Duong, Phuong-Anh; Little, Brent P

    2014-08-01

    Implementation of a comprehensive computed tomography (CT) radiation dose-reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and an ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose-reduction program and discuss the use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and the dose-reduction techniques, showing how an understanding of each technique is important in effective auditing of "outlier" doses identified by dose tracking. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. The assessment of collective dose for travellers travelling by water

    International Nuclear Information System (INIS)

    Yue Qingyu; Jiang Ping; Jin Hua

    1992-06-01

    The major contribution to the various radiation exposure received by mankind comes from natural radiation. Some environmental change caused by human beings and some activities of mankind may decrease or increase the radiation exposure level from natural radiation. People travelling by air will receive more exposure dose and by water will receive less. China has about 18000 km coast line and the inland water transportation is very flourishing. According to statistic data from Ministry of Transportation in 1988, the turnover in that year was about 2 x 10 10 man.km. The total number of fisherman for inshore fishing was nearly two million reported by Ministry of Farming, Animal Husbandry and Fishery. We measured 212 points in six typical shipping lines of inshore lines and inland rivers, and the distance was 5625 km. The average natural radiation exposure dose rate received by travellers in each shipping line was calculated. From that the assessment of collective dose equivalent for passengers by water and fishermen was derived. The value is 32.7 man.Sv for passengers and 265.3 man.Sv for fishermen

  14. The assessment of collective dose for travellers travelling by water

    International Nuclear Information System (INIS)

    Yue Qingyu; Jian Ping; Jin Hua

    1994-01-01

    The major contribution to various radiation exposure received by mankind comes from natural radiation. Some environmental change caused by human beings and some activities of mankind may decrease or increase the radiation exposure level from natural radiation. China has about 18000 km coast line and the inland water transportation is very flourishing. According to statistic data from Ministry of Transportation in 1988, the turnover in that year was about 2 x 10 10 man·km. The total number of fisherman for inshore fishing was nearly two millions reported by Ministry of Farming, Animal Husbandry and Fishery. We measured exposure dose rates over 212 points in six typical shipping lines of inshore lines and inland rivers, and the distance was 5625 km. The average natural radiation exposure dose rate received by travellers in each shipping line was calculated. From that the assessment of collective dose equivalent for passengers by water and fishermen was derived. The value is 32.7 man·Sv for passengers and 265.3 man·Sv for fishermen

  15. Head-and-neck IMRT treatments assessed with a Monte Carlo dose calculation engine

    International Nuclear Information System (INIS)

    Seco, J; Adams, E; Bidmead, M; Partridge, M; Verhaegen, F

    2005-01-01

    IMRT is frequently used in the head-and-neck region, which contains materials of widely differing densities (soft tissue, bone, air-cavities). Conventional methods of dose computation for these complex, inhomogeneous IMRT cases involve significant approximations. In the present work, a methodology for the development, commissioning and implementation of a Monte Carlo (MC) dose calculation engine for intensity modulated radiotherapy (MC-IMRT) is proposed which can be used by radiotherapy centres interested in developing MC-IMRT capabilities for research or clinical evaluations. The method proposes three levels for developing, commissioning and maintaining a MC-IMRT dose calculation engine: (a) development of a MC model of the linear accelerator, (b) validation of MC model for IMRT and (c) periodic quality assurance (QA) of the MC-IMRT system. The first step, level (a), in developing an MC-IMRT system is to build a model of the linac that correctly predicts standard open field measurements for percentage depth-dose and off-axis ratios. Validation of MC-IMRT, level (b), can be performed in a rando phantom and in a homogeneous water equivalent phantom. Ultimately, periodic quality assurance of the MC-IMRT system is needed to verify the MC-IMRT dose calculation system, level (c). Once the MC-IMRT dose calculation system is commissioned it can be applied to more complex clinical IMRT treatments. The MC-IMRT system implemented at the Royal Marsden Hospital was used for IMRT calculations for a patient undergoing treatment for primary disease with nodal involvement in the head-and-neck region (primary treated to 65 Gy and nodes to 54 Gy), while sparing the spinal cord, brain stem and parotid glands. Preliminary MC results predict a decrease of approximately 1-2 Gy in the median dose of both the primary tumour and nodal volumes (compared with both pencil beam and collapsed cone). This is possibly due to the large air-cavity (the larynx of the patient) situated in the centre

  16. Recent developments in biokinetic models and the calculation of internal dose coefficients

    International Nuclear Information System (INIS)

    Fell, T.P.; Phipps, A.W.; Kendall, G.M.; Stradling, G.N.

    1997-01-01

    In most cases the measurement of radioactivity in an environmental or biological sample will be followed by some estimation of dose and possibly risk, either to a population or an individual. This will normally involve the use of a dose coefficient (dose per unit intake value) taken from a compendium. In recent years the calculation of dose coefficients has seen many developments in both biokinetic modelling and computational capabilities. ICRP has recommended new models for the respiratory tract and for the systemic behavior of many of the more important elements. As well as this, a general age-dependent calculation method has been developed which involves an effectively continuous variation of both biokinetic and dosimetric parameters, facilitating more realistic estimation of doses to young people. These new developments were used in work for recent ICRP, IAEA and CEC compendia of dose coefficients for both members of the public (including children) and workers. This paper presents a general overview of the method of calculation of internal doses with particular reference to the actinides. Some of the implications for dose coefficients of the new models are discussed. For example it is shown that compared with data in ICRP Publications 30 and 54: the new respiratory tract model generally predicts lower deposition in systemic tissues per unit intake; the new biokinetic models for actinides allow for burial of material deposited on bone surfaces; age-dependent models generally feature faster turnover of material in young people. All of these factors can lead to substantially different estimates of dose and examples of the new dose coefficients are given to illustrate these differences. During the development of the new models for actinides, human bioassay data were used to validate the model. Thus, one would expect the new models to give reasonable predictions of bioassay quantities. Some examples of the bioassay applications, e.g., excretion data for the

  17. Development of Monte Carlo simulations to provide scanner-specific organ dose coefficients for contemporary CT

    Science.gov (United States)

    Jansen, Jan T. M.; Shrimpton, Paul C.

    2016-07-01

    The ImPACT (imaging performance assessment of CT scanners) CT patient dosimetry calculator is still used world-wide to estimate organ and effective doses (E) for computed tomography (CT) examinations, although the tool is based on Monte Carlo calculations reflecting practice in the early 1990’s. Subsequent developments in CT scanners, definitions of E, anthropomorphic phantoms, computers and radiation transport codes, have all fuelled an urgent need for updated organ dose conversion factors for contemporary CT. A new system for such simulations has been developed and satisfactorily tested. Benchmark comparisons of normalised organ doses presently derived for three old scanners (General Electric 9800, Philips Tomoscan LX and Siemens Somatom DRH) are within 5% of published values. Moreover, calculated normalised values of CT Dose Index for these scanners are in reasonable agreement (within measurement and computational uncertainties of  ±6% and  ±1%, respectively) with reported standard measurements. Organ dose coefficients calculated for a contemporary CT scanner (Siemens Somatom Sensation 16) demonstrate potential deviations by up to around 30% from the surrogate values presently assumed (through a scanner matching process) when using the ImPACT CT Dosimetry tool for newer scanners. Also, illustrative estimates of E for some typical examinations and a range of anthropomorphic phantoms demonstrate the significant differences (by some 10’s of percent) that can arise when changing from the previously adopted stylised mathematical phantom to the voxel phantoms presently recommended by the International Commission on Radiological Protection (ICRP), and when following the 2007 ICRP recommendations (updated from 1990) concerning tissue weighting factors. Further simulations with the validated dosimetry system will provide updated series of dose coefficients for a wide range of contemporary scanners.

  18. Radiological assessment of worker doses during sludge mobilization and removal at the Melton Valley storage tanks

    International Nuclear Information System (INIS)

    Kerr, G.D.; Coleman, R.L.; Kocher, D.C.; Wynn, C.C.

    1996-01-01

    This report presents an assessment of potential radiation doses to workers during mobilization and removal of contaminated sludges from the Melton Valley Storage Tanks at Oak Ridge National Laboratory. The assessment is based on (1) measurements of radionuclide concentrations in sludge and supernatant liquid samples from the waste storage tanks, (2) measurements of gamma radiation levels in various areas that will be accessed by workers during normal activities, (3) calculations of gamma radiation levels for particular exposure situations, especially when the available measurements are not applicable, and (4) assumed scenarios for worker activities in radiation areas. Only doses from external exposure are estimated in this assessment. Doses from internal exposure are assumed to be controlled by containment of radioactive materials or respiratory protection of workers and are not estimated

  19. Dose assessments for Greifswald and Cadarache with new source terms from ITER NSSR-1

    International Nuclear Information System (INIS)

    Raskob, W.; Forschungszentrum Karlsruhe GmbH Technik und Umwelt; Hasemann, I.

    1997-08-01

    Probabilistic dose assessments for accidental atmospheric releases of various ITER source terms which contain tritium and/or activation products were performed for the sites of Greifswald, Germany, and Cadarache, France. No country specific rules were applied and the input parameters were adapted as far as possible to those used within former ITER studies to achieve a better comparability with site independent dose assessments performed in the frame of ITER. The calculations were based on source terms which, at the first time, contain a combination of tritium and activation products. This allowed a better judgement of the contribution of the individual fusion relevant materials to the total dose. The results were compared to site independent dose limits defined in the frame of ITER. Source terms for two different categories, representing 'extremely unlikely events' (CAT-IV) and 'hypothetical sequences' (CAT-V), were investigated. In no cases, the release scenarios of category CAT-IV exceeded the ITER limits. In addition, early doses from the hypothetical scenarios of type CAT-V were still below 50 mSv or 100 mSv, values which are commonly used as lower reference values for evacuation in many potential home countries of ITER. Only the banning of food products was found to be a potential countermeasure which may affect larger areas. (orig.) [de

  20. WAYS TO INCREASE ACCURACY AND RELIABILITY OF INDIVIDUAL DOSES ASSESSMENTS IN PERSONNEL WITHIN THERMOLUMINESCENCE TECHNIQUE

    Directory of Open Access Journals (Sweden)

    G. N. Kaydanovskiy

    2012-01-01

    Full Text Available The paper analyses the main sources of measurement errors of individual doses in personnel performed within the thermoluminescence technique and gives recommendations to minimize these errors. The reasons that reduce reliability of effective dose assessments derived from measured values of personal dose equivalent are imperfections of guidance documents. Changes to the Guidelines «Organization and implementation of individual dosimetric control. Staff of health institutions» are justified.

  1. Outline of manual on measurement and assessment of doses from external radiation

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizawa, Michio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Tsujimura, Norio

    2001-03-01

    The external exposure part in the manual for measurement and assessment of doses from external radiation is described since the part is changed in accordance with the revision of the Law Concerning Prevention from Radiation Hazard due to Radioisotopes, Etc. The manual contains general remarks, control of external exposure and its methods, person monitoring, site monitoring, correction of instruments and storage of records. The 2nd and 3rd chapters are described in details, because which are considerably changed together with appendices concerning the operational quantity for measuring external dose, conversion coefficients, and correlations of 3 mm, 1 cm and 70 {mu}m dose equivalents. Making manuals unique to the individual offices, etc. is recommended in compliance with the above manual.(K.H.)

  2. Technology Development for Radiation Dose Measurement and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Hwan; Chang, S. Y.; Lee, T. Y. (and others)

    2007-06-15

    The correction factors essential for the operation of In-Vivo counting system were produced and implemented into a field operation for the improvement of accuracy in measurement of the radioactivity inside a human body. The BiDAS2007 code which calculate an internal dose was developed by upgrading the former code prepared in the previous stage of this project. The method of using the multibioassy data, the maximum likelihood function and the Bayesian statistics were established to an internal dose based on the measurement data of radioactivity, intakes and retention of radioactivity in a human body and it can improve the accuracy in estimation of the intakes of radioactivity and the committed effective dose equivalent. In order to solve the problem of low detection efficiency of the conventional Bonner Sphere (BS) to a high energy neutron, the extended BS's were manufactured and the technique for neutron field spectrometry was established. The fast neutron and gamma spectrometry system with a BC501A scintillation detector was also prepared. Several neutron fluence spectra at several nuclear facilities were measured and collected by using the extended BS. The spectrum weighted responses of some neutron monitoring instruments were also derived by using these spectra and the detector response functions. A high efficient TL material for the neutron personal dosimeter was developed. It solved the main problem of low thermal stability and high residual dose of the commercial TLDs and has the sensitivity to neutron and to gamma radiation with 40 and 10 times higher respectively than them.

  3. Radiation Dose Assessment Model for Marine Biota (K-BIOTA-DYN-M)

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong-Kwon; Kim, Byeong-Ho; Jun, In; Lim, Kwang-Muk; Choi, Yong-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    In this study, a dynamic compartment model based on the food chain of marine biota, which can be used with easily obtainable ecological parameters, is presented to predict the activity concentration and dose rate of marine biota as a result of a nuclear. The model was applied to investigate a long-term effect of the Fukushima accident on the marine biota by using {sup 131}I, {sup 134}Cs, and {sup 137}Cs activity concentrations of seawater measured for up to about 2.5years after the accident in the port of FDNPS, which was known to be the most severely contaminated. A dynamic compartment model was presented to assess the activity concentration and whole body dose rate of marine biota, and was tested through the prediction of the activity concentration and dose rate of the marine biota using the seawater activities of {sup 131}I, {sup 134}Cs, and {sup 137}Cs measured after the accident at two locations in the port of the Fukushima Daiichi Nuclear Power Station (FDNPS), as a result the Fukushima nuclear accident that occurred on March 11, 2011. The prediction results showed the radiological effect on the population of the marine biota as a consequence of the accident was insignificant. This result is also valid for biota in a less contaminated offshore because the present assessment was made for the most highly contaminated area such as marine ecosystem in the port of FDNPS. Conclusively, the present dynamic model can be usefully applied to estimate the activity concentration and whole body dose rate of the marine biota as the consequence of a nuclear accident.

  4. Experimental assessment of absorbed dose to mineralized bone tissue from internal emitters: An electron paramagnetic resonance study

    International Nuclear Information System (INIS)

    Desrosiers, M.F.

    1994-01-01

    EPR resonances attributable to radiation-induced centers in hydroxyapatite were not detectable in bone samples supplied by the USTUR. These centers are the basis for imaging and dose assessment. Presumable, the short range of the alpha particles emitted precluded the formation of appreciable amounts of hydroxyapatite centers. However, one bone sample did offer a suggestion of hydroxyapatite centers and newly-developed methods to extract this information will be pursued

  5. Using plant biomonitors and flux modelling to develop O3 dose-response relationships in Catalonia

    International Nuclear Information System (INIS)

    Filella, Iolanda; Pen-tilde uelas, Josep; Ribas, Angela

    2005-01-01

    We used tobacco Bel-W3 biomonitoring data and ozone flux modelling (WINDEP model) with the aim of developing the absorbed dose-response relationship, and comparing this approach with the most commonly used AOT40 (the sum of hourly ozone concentrations above a cut-off of 40 ppb during daylight hours, when global radiation exceeds 50 W m -2 ) in the estimation of exposure-damage curves. Leaf damage values were more related to OAD 15days,potential (potential ozone absorbed dose calculated over 15 consecutive days) than to AOT40 in all the studied stations. An OAD 15days,potential of 180 mg m -2 was found to be the threshold for damage to the most sensitive species in this region under well watered conditions. The results show the applicability of the flux approach for risk assessment at the local scale, the improvement of the ozone damage estimation when the potential absorbed dose is modelled and used instead of just the ozone exposure, and finally, the possibilities opened by the use of biomonitoring networks. - Modelling of biomonitors ozone absorbed dose improves damage estimation in comparison with exposure indices such as AOT40

  6. Evaluation of the use of ICRP 60 dose conversion factors in a postclosure assessment of a deep geological disposal system

    International Nuclear Information System (INIS)

    Palattao, M.V.B.; Hajas, W.C.; Goodwin, B.W.

    1997-05-01

    An Environmental Impact Statement (EIS) of the concept for disposal of Canada's nuclear fuel waste was completed in 1994 and is currently under review by an independent Review Panel. This EIS included a postclosure assessment case study to estimate the annual effective dose equivalent in sieverts per year to members of the public; these estimates were obtained using dose conversion factors (DCFS) based on the 1977 recommendations of the International Commission on Radiation Protection (ICRP). However, in 1990 the ICRP revised these recommendations based on additional biological information and developments in radiation protection. This report describes a study of how the more recent recommendations of the ICRP would affect the results of the postclosure assessment case study presented in the EIS. The report includes a theoretical description of how DCFs are used and a comparison of results from computer simulations using the 1977 and the 1990 ICRP recommendations. In the EIS case study, which was based on the 1977 ICRP recommendations, the total dose rate to a member of the critical group is more than six orders of magnitude below the dose rate associated with the regulatory criterion for individual radiological risk. The total dose rate to 10 4 years is dominated by 129 I, with smaller contributions from 36 C1 and 14 C. If the 1990 ICRP recommendations were implemented, the total dose rate would be mostly affected by the new DCF for 129 I, and would increase by about 67%. Even with this increase, the total dose rate would still remain many orders of magnitude lower than the dose rate associated with the regulatory risk criterion. (author)

  7. Separate assessment of natural beta and gamma dose-rates with TL from α-Al2O3:C single-crystal chips

    International Nuclear Information System (INIS)

    Kalchgruber, R.; Wagner, G.A.

    2006-01-01

    A measurement procedure was developed for fast and separate assessment of beta and gamma dose-rates in natural sediments using highly sensitive α-Al 2 O 3 :C single-crystal chips. The dosemeters were buried for periods from two days to three weeks in sediments with different layer structure and homogeneity. For each measurement, a pair of dosemeters was buried, in order to assess beta and gamma dose-rates separately. One dosemeter was wrapped only in thin plastic foil to shield it from alpha radiation, thus measuring beta + gamma components. The second one, used for the gamma component only, was packed additionally in a 1mm copper container for absorption of beta radiation. For calibration, another set of dosemeters was buried in reference soil with a well-known dose-rate and similar content of radioactive nuclides. By comparing the thermally stimulated luminescence signals from the dosemeters the gamma dose-rate and also, by subtraction, the beta dose-rate in the unknown soil could be determined. The calculated uncertainties were 5-7% and 10%, respectively. The resulting dose-rates for homogeneous and inhomogeneous media were compared with the results obtained by Ge- and on-site NaI-gamma-ray spectrometry. An agreement within 2σ-error limits was found for homogeneous media after only few days of exposure

  8. Virtual reality based adaptive dose assessment method for arbitrary geometries in nuclear facility decommissioning.

    Science.gov (United States)

    Liu, Yong-Kuo; Chao, Nan; Xia, Hong; Peng, Min-Jun; Ayodeji, Abiodun

    2018-05-17

    This paper presents an improved and efficient virtual reality-based adaptive dose assessment method (VRBAM) applicable to the cutting and dismantling tasks in nuclear facility decommissioning. The method combines the modeling strength of virtual reality with the flexibility of adaptive technology. The initial geometry is designed with the three-dimensional computer-aided design tools, and a hybrid model composed of cuboids and a point-cloud is generated automatically according to the virtual model of the object. In order to improve the efficiency of dose calculation while retaining accuracy, the hybrid model is converted to a weighted point-cloud model, and the point kernels are generated by adaptively simplifying the weighted point-cloud model according to the detector position, an approach that is suitable for arbitrary geometries. The dose rates are calculated with the Point-Kernel method. To account for radiation scattering effects, buildup factors are calculated with the Geometric-Progression formula in the fitting function. The geometric modeling capability of VRBAM was verified by simulating basic geometries, which included a convex surface, a concave surface, a flat surface and their combination. The simulation results show that the VRBAM is more flexible and superior to other approaches in modeling complex geometries. In this paper, the computation time and dose rate results obtained from the proposed method were also compared with those obtained using the MCNP code and an earlier virtual reality-based method (VRBM) developed by the same authors. © 2018 IOP Publishing Ltd.

  9. Assessment of dose load of personnel in intratissue gamma beam therapy

    International Nuclear Information System (INIS)

    Stavitskij, R.V.; Zamyatin, O.A.; Varennikov, O.I.; Astakhova, I.V.

    1995-01-01

    Suggest a method for retrospective assessment of levels of irradiation of small groups of personnel exposed to radiation sources. Presents estimated values of cumulative and local doses obtained by personnel during intratissue gamma beam therapy carried out by manual consecutive injections of intrastats and irradiation sources. 3 refs.; 5 tabs

  10. In vivo assessment of the gastric mucosal tolerance dose after single fraction, small volume irradiation of liver malignancies by computed tomography-guided, high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Streitparth, Florian; Pech, Maciej; Boehmig, Michael; Ruehl, Ricarda; Peters, Nils; Wieners, Gero; Steinberg, Johannes; Lopez-Haenninen, Enrique; Felix, Roland; Wust, Peter; Ricke, Jens

    2006-01-01

    Purpose: The aim of this study was to assess the tolerance dose of gastric mucosa for single-fraction computed tomography (CT)-guided, high-dose-rate (HDR) brachytherapy of liver malignancies. Methods and Materials: A total of 33 patients treated by CT-guided HDR brachytherapy of liver malignancies in segments II and/or III were included. Dose planning was performed upon a three-dimensional CT data set acquired after percutaneous applicator positioning. All patients received gastric protection post-treatment. For further analysis, the contours of the gastric wall were defined in every CT slice using Brachyvision Software. Dose-volume histograms were calculated for each treatment and correlated with clinical data derived from questionnaires assessing Common Toxicity Criteria (CTC). All patients presenting symptoms of upper GI toxicity were examined endoscopically. Results: Summarizing all patients the minimum dose applied to 1 ml of the gastric wall (D 1ml ) ranged from 6.3 to 34.2 Gy; median, 14.3 Gy. Toxicity was present in 18 patients (55%). We found nausea in 16 (69%), emesis in 9 (27%), cramping in 13 (39%), weight loss in 12 (36%), gastritis in 4 (12%), and ulceration in 5 patients (15%). We found a threshold dose D 1ml of 11 Gy for general gastric toxicity and 15.5 Gy for gastric ulceration verified by an univariate analysis (p = 0.01). Conclusions: For a single fraction, small volume irradiation we found in the upper abdomen a threshold dose D 1ml of 15.5 Gy for the clinical endpoint ulceration of the gastric mucosa. This in vivo assessment is in accordance with previously published tolerance data

  11. External contamination and skin dose. From ICRP and regulations to skin dose evaluation in practice

    International Nuclear Information System (INIS)

    Le Coulteulx, I.; Apretna, D.; Beaugerie, M.; Fenolland, J.; Frey, R.; Gonin, M.; Landry, B.; Laporte, E.; Le Guen, B.; Leval, D.

    2006-01-01

    Dose limitation to the skin is an objective of radiation protection. Our aim is to propose in case of skin contamination in EDF NPPs a simply, quickly and reproducible procedure for evaluating skin dose. French regulation admit an annual limit for skin dose over one square centimeter equal to 500 mSv. ICRP Publication 26 and 60 recommend that dose assessment be performed only if skin dose might be equal to or more than 50 mSv at basal cells. To respect this recommendation, an alert value (A) must be determined. This value is the lowest value of measurement from which dose assessment has to be made, based on the hypothesis that uninterrupted work time in controlled area is no more than four hours. This alert value (A) has been established for three external detection equipments, and for the ten radionuclides commonly detected. In case of external contamination, a first measurement is performed. If the value exceeds value (A), other measurements are instituted because skin dose evaluation needs to know other parameters as: - the radioactivity of the most contaminated square centimeter of the skin, - the identity of the radionuclides and their relative proportion. At the same time, we have to evaluate the length of the exposure. At last, we use different compiled results in a program developed from excel software which allow to calculate automatically the skin dose. This work has allowed us to publish an occupational health guideline about the assessment of skin dose in case of external contamination in EDF NPPs and to create an information booklet for workers. The authors propose to examine used methodology and to demonstrate the software. (authors)

  12. Proposal of a dosemeter for skin beta radiation dose assessment

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da; Caldas, L.V.E.

    1987-08-01

    Beta radiation is, undoubtedly, less penetrating than X or gamma radiation. Thus, beta radiation sources external to the human body do not cause a significant irradiation of its deeper tissues. However, in some cases, they may contribute in a very important way to the irradiation of the lens of the eyes and, mainly, of the skin. Specially, the hands and finger tips may receive a high dose. In this work some relevant aspects of the individual monitoring in beta radiation fields are discussed and the importance of monitoring this kind of radiation in some activities where the skin absorbed dose may be a limiting factor is evidenced. The main characteristics of the thermoluminescent (TL) response of ultra-thin CaSO 4 : Dy detectors (UT-CaSO 4 : Dy) in the detection of this kind of radiation are also studied. The irradiation are performed with 90 Sr 90 Y, 204 TI and 147 Pm sources. The reproducibility, linearity, dependence on the absorbed dose rate, optical fading, energy and angular dependences of the detector TL responce are investigated. Transmission factors for different thicknesses of tissue equivalent material are obtained for the TL detectors using the three available beta sources. Based on the results obtained, a dosemeter for skin beta radiation absorbed dose assessment with an energy dependence better than 12% is proposed. (Author) [pt

  13. Smartphone apps for calculating insulin dose: a systematic assessment.

    Science.gov (United States)

    Huckvale, Kit; Adomaviciute, Samanta; Prieto, José Tomás; Leow, Melvin Khee-Shing; Car, Josip

    2015-05-06

    Medical apps are widely available, increasingly used by patients and clinicians, and are being actively promoted for use in routine care. However, there is little systematic evidence exploring possible risks associated with apps intended for patient use. Because self-medication errors are a recognized source of avoidable harm, apps that affect medication use, such as dose calculators, deserve particular scrutiny. We explored the accuracy and clinical suitability of apps for calculating medication doses, focusing on insulin calculators for patients with diabetes as a representative use for a prevalent long-term condition. We performed a systematic assessment of all English-language rapid/short-acting insulin dose calculators available for iOS and Android. Searches identified 46 calculators that performed simple mathematical operations using planned carbohydrate intake and measured blood glucose. While 59% (n = 27/46) of apps included a clinical disclaimer, only 30% (n = 14/46) documented the calculation formula. 91% (n = 42/46) lacked numeric input validation, 59% (n = 27/46) allowed calculation when one or more values were missing, 48% (n = 22/46) used ambiguous terminology, 9% (n = 4/46) did not use adequate numeric precision and 4% (n = 2/46) did not store parameters faithfully. 67% (n = 31/46) of apps carried a risk of inappropriate output dose recommendation that either violated basic clinical assumptions (48%, n = 22/46) or did not match a stated formula (14%, n = 3/21) or correctly update in response to changing user inputs (37%, n = 17/46). Only one app, for iOS, was issue-free according to our criteria. No significant differences were observed in issue prevalence by payment model or platform. The majority of insulin dose calculator apps provide no protection against, and may actively contribute to, incorrect or inappropriate dose recommendations that put current users at risk of both catastrophic overdose and more

  14. The ecosystem models used for dose assessments in SR-Can

    Energy Technology Data Exchange (ETDEWEB)

    Avila, Rodolfo [Facilia AB, Bromma (Sweden)

    2006-11-15

    chronic contamination. From the simulations for the different release cases, activity concentrations in water and soil are obtained and then multiplied with the aggregated transfer factors to obtain concentrations in food products. For terrestrial ecosystems, the aggregated transfer factors in Becquerel per Kilogram of edible carbon in the food are used to calculate the activity intake and from this the effective dose rate per unit release to an adult individual. For aquatic ecosystems, only doses from the ingestion of water (for lakes) and food (for sea and lakes) are considered, as previous assessments have shown that in these types of ecosystems other exposure pathways give a very low contribution to the total doses. A sensitivity analysis of the ecosystem models is presented in the report, identifying which parameters have the largest effect on the simulation endpoints of interest. The endpoints considered are the fraction of the release that is retained in the ecosystem, the activity concentrations in soil, water and sediments, and the total dose rates from external exposure, inhalation, and ingestion of water and food. These endpoints are evaluated at different times within the simulation and a sensitivity analysis using the Morris method is carried out. For some of the scenarios considered in SR-Can, the LDF concept is not applicable. One of these scenarios comprises the contamination of ground caused by inadvertent drilling into the repository. Doses which would arise for a family using this contaminated ground for housing and food production are estimated. The other scenario which is assessed separately is the release of C-14 and Rn-222 from the repository in gaseous form, entering the biosphere via soil as a diffuse source. Pathways considered are doses from ingestion of C-14 and from inhalation of C-14 and Rn-222 outdoors as well as indoors. For these scenarios, specific dose calculations were carried out. The methods applied for these calculations and the

  15. The ecosystem models used for dose assessments in SR-Can

    International Nuclear Information System (INIS)

    Avila, Rodolfo

    2006-11-01

    chronic contamination. From the simulations for the different release cases, activity concentrations in water and soil are obtained and then multiplied with the aggregated transfer factors to obtain concentrations in food products. For terrestrial ecosystems, the aggregated transfer factors in Becquerel per Kilogram of edible carbon in the food are used to calculate the activity intake and from this the effective dose rate per unit release to an adult individual. For aquatic ecosystems, only doses from the ingestion of water (for lakes) and food (for sea and lakes) are considered, as previous assessments have shown that in these types of ecosystems other exposure pathways give a very low contribution to the total doses. A sensitivity analysis of the ecosystem models is presented in the report, identifying which parameters have the largest effect on the simulation endpoints of interest. The endpoints considered are the fraction of the release that is retained in the ecosystem, the activity concentrations in soil, water and sediments, and the total dose rates from external exposure, inhalation, and ingestion of water and food. These endpoints are evaluated at different times within the simulation and a sensitivity analysis using the Morris method is carried out. For some of the scenarios considered in SR-Can, the LDF concept is not applicable. One of these scenarios comprises the contamination of ground caused by inadvertent drilling into the repository. Doses which would arise for a family using this contaminated ground for housing and food production are estimated. The other scenario which is assessed separately is the release of C-14 and Rn-222 from the repository in gaseous form, entering the biosphere via soil as a diffuse source. Pathways considered are doses from ingestion of C-14 and from inhalation of C-14 and Rn-222 outdoors as well as indoors. For these scenarios, specific dose calculations were carried out. The methods applied for these calculations and the

  16. Assessment of dose measurement uncertainty using RisøScan

    DEFF Research Database (Denmark)

    Helt-Hansen, J.; Miller, A.

    2006-01-01

    The dose measurement uncertainty of the dosimeter system RisoScan, office scanner and Riso B3 dosimeters has been assessed by comparison with spectrophotometer measurements of the same dosimeters. The reproducibility and the combined uncertainty were found to be approximately 2% and 4%, respectiv......%, respectively, at one standard deviation. The subroutine in RisoScan for electron energy measurement is shown to give results that are equivalent to the measurements with a scanning spectrophotometer. (c) 2006 Elsevier Ltd. All rights reserved....

  17. Assessment of radiation doses from residential smoke detectors that contain americium-241

    International Nuclear Information System (INIS)

    O'Donnell, F.R.; Etnier, E.L.; Holton, G.A.; Travis, C.C.

    1981-10-01

    External dose equivalents and internal dose commitments were estimated for individuals and populations from annual distribution, use, and disposal of 10 million ionization chamber smoke detectors that contain 110 kBq (3 μCi) americium-241 each. Under exposure scenarios developed for normal distribution, use, and disposal using the best available information, annual external dose equivalents to average individuals were estimated to range from 4 fSv (0.4 prem) to 20 nSv (2 μrem) for total body and from 7 fSv to 40 nSv for bone. Internal dose commitments to individuals under post disposal scenarios were estimated to range from 0.006 to 80 μSv (0.0006 to 8 mrem) to total body and from 0.06 to 800 μSv to bone. The total collective dose (the sum of external dose equivalents and 50-year internal dose commitments) for all individuals involved with distribution, use, or disposal of 10 million smoke detectors was estimated

  18. Eye dose assessment and management: overview

    International Nuclear Information System (INIS)

    Rehani, M.M.

    2015-01-01

    Some publications have shown that Hp( 0.07 ) or even Hp( 10 ) can be used as good operational quantities for X-rays in view of difficulties with Hp( 3 ). With increasing awareness, there is tendency to use whatever dosimeter is available with correction factor to estimate eye lens dose. The best position for an eye lens dosimeter has been reported to be at the side of the head nearest to the radiation source, close to the eye. Recent studies have reported eye doses with cone beam CT (CBCT) both for patients and staff, and there are many papers reporting eye lens doses to staff in nuclear medicine. To minimise the dose to eyes, the user can take advantage of a feature of CBCT of projections acquired over an angular span of 1808 plus cone angle of the X-ray tube and with tube under scan arcs. (authors)

  19. Population dose assessment from radiodiagnosis in Portugal

    International Nuclear Information System (INIS)

    Serro, R.; Carreiro, J.V.; Galvao, J.P.; Reis, R.

    1992-01-01

    A survey of radiodiagnostic installations was carried out in Portugal covering 75 premises including public hospitals, local and regional public health centres. A total of 175 X ray tubes was surveyed using the new NEXT methodology covering data on premises, tube and operator, and projection. Average value of voltage, current-time product, HVL, ratio of beam area to film area and source to film distance for the eleven most frequent projections are reported as well as the skin entrance exposure and the doses to some organs. The weighted average dose values per projection and for the different organs allowed an estimate of the whole-body dose per caput. From the gonadal doses the genetic significant dose was also estimated

  20. Occupational exposure of phosphate mine workers: airborne radioactivity measurements and dose assessment

    International Nuclear Information System (INIS)

    Khater, Ashraf E.; Hussein, M.A.; Hussein, Mohamed I.

    2004-01-01

    Under the Egyptian program for radiation safety and control, airborne radioactivity measurements and radiological dose assessment were conducted in some phosphate and uranium mines. Abu-Tartor mine is one of the biggest underground phosphate mines in Egypt. Airborne radioactivity, radon ( 222 Rn) and its short-lived decay products (progenies) and thoron ( 220 Rn), were measured in selected locations along the mine. The environmental gamma and workers dose equivalent rate (mSv/y) were measured inside and outside the mine using thermo-luminescence dosimeters (TLD). The results were presented and discussed. The calculated annual effective dose due to airborne radioactivity is the main source of occupational exposure and exceeding the maximum recommended level by ICRP-60 inside the mine tunnels. A number of recommendations are suggested to control the occupational exposures

  1. Application of Whole Body Counter to Neutron Dose Assessment in Criticality Accidents

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, O.; Tsujimura, N.; Takasaki, K.; Momose, T.; Maruo, Y. [Japan Nuclear Cycle Development Institute, Tokai (Japan)

    2001-09-15

    Neutron dose assessment in criticality accidents using Whole Body Counter (WBC) was proved to be an effective method as rapid neutron dose estimation at the JCO criticality accident in Tokai-mura. The 1.36MeV gamma-ray of {sup 24}Na in a body can be detected easily by a germanium detector. The Minimum Detectable Activity (MDA) of {sup 24}Na is approximately 50Bq for 10minute measurement by the germanium-type whole body counter at JNC Tokai Works. Neutron energy spectra at the typical shielding conditions in criticality accidents were calculated and the conversion factor, whole body activity-to-organ mass weighted neutron absorbed dose, corresponding to each condition were determined. The conversion factor for uncollied fission spectrum is 7.7 [(Bq{sup 24}Na/g{sup 23}Na)/mGy].

  2. Development of Japanese voxel models and their application to organ dose calculation

    International Nuclear Information System (INIS)

    Sato, Kaoru; Endo, Akira; Saito, Kimiaki

    2007-01-01

    Three Japanese voxel (volume pixel) phantoms in supine and upright postures, which are consisted of about 1 mm 3 size voxels, have been developed on the basis of computed tomography (CT) images of healthy Japanese adult male and female volunteers. Their body structures are reproduced more realistically in comparison with most existing voxel phantoms. Organ doses due to internal or external exposures were calculated using the developed phantoms. In estimation of radiation dose from radionuclides incorporated into body, specific absorbed fractions (SAFs) for low energy photon were significantly influenced by the changes in postures. In estimation of organ doses due to external exposures, the doses of some organs of the developed phantom were calculated and were compared with those of a previous Japanese voxel phantom (voxel size: 0.98x0.98x10 mm 3 ) and the reference values of ICRP Publication 74. (author)

  3. Radiation dose during angiographic procedures

    International Nuclear Information System (INIS)

    Lavoie, Ch.; Rasuli, P.

    2001-01-01

    The use of angiographic procedures is becoming more prevalent as new techniques and equipment are developed. There have been concerns in the scientific community about the level of radiation doses received by patients, and indirectly by staff, during some of these radiological procedures. The purpose of this study was to assess the level of radiation dose from angiographic procedures to patient at the Ottawa Hospital, General Campus. Radiation dose measurements, using Thermo-Luminescent Dosimeters (TLDs), were performed on more than 100 patients on various procedures. The results show that while the patient dose from the great majority of angiographic procedures is less than 2 Gy, a significant number of procedures, especially interventional procedures may have doses greater than 2 Gy and may lead to deterministic effects. (author)

  4. Recent developments in human biomonitoring: non-invasive assessment of target tissue dose and effects of pneumotoxic metals.

    Science.gov (United States)

    Mutti, A; Corradi, M

    2006-01-01

    Tobacco smoke and polluted environments substantially increase the lung burden of pneumotoxic chemicals, particularly pneumotoxic metallic elements. To achieve a better understanding of the early events between exposure to inhaled toxicants and the onset of adverse effects on the lung, the characterization of dose at the target organ would be extremely useful. Exhaled breath condensate (EBC), obtained by cooling exhaled air under conditions of spontaneous breathing, is a novel technique that could provide a non-invasive assessment of pulmonary pathobiology. Considering that EBC is water practically free of interfering solutes, it represents an ideal biological matrix for elemental characterization. Published data show that several toxic metals and trace elements are detectable in EBC, raising the possibility of using this medium to quantify the lung tissue dose of pneumotoxic substances. This novel approach may represent a significant advance over the analysis of alternative media (blood, serum, urine, hair), which are not as reliable (owing to interfering substances in the complex matrix) and reflect systemic rather than lung (target tissue) levels of both toxic metals and essential trace elements. Data obtained among workers occupationally exposed to either hard metals or chromium (VI) and in smokers with or without chronic obstructive pulmonary disease (COPD) are reviewed to show that--together with biomarkers of exposure--EBC also allows the simultaneous quantification of biomarkers of effect directly sampled from the epithelial lining fluid, thus providing novel insights on both kinetic and dynamic aspects of metal toxicology.

  5. Dose assessment following an overexposure of a worker at a Swiss nuclear power plant.

    Science.gov (United States)

    Bailat, Claude J; Laedermann, Jean-Pascal; Baechler, Sébastien; Desorgher, Laurent; Aroua, Abbas; Bochud, François O

    2017-12-01

    The aim of this work was to assess the doses received by a diver exposed to a radiation source during maintenance work in the fuel transfer pool at a Swiss nuclear power plant, and to define whether the statutory limit was breached or not. Onsite measurements were carried out and different scenarios were simulated using the MicroShield Software and the MCNPX Monte Carlo radiation transport code to estimate the activity of the irradiating object as well as the doses to the limbs and the effective dose delivered to the operator. The activity of the object was estimated to 1.8 TBq. From the various dose estimations, a conservative value of 7.5 Sv was proposed for the equivalent dose to the skin on the hands and an effective dose of 28 mSv. The use of different experimental and calculation methods allowed us to accurately estimate the activity of the object and the dose delivered to the diver, useful information for making a decision on the most appropriate scheme of follow up for the patient.

  6. NAIRAS aircraft radiation model development, dose climatology, and initial validation.

    Science.gov (United States)

    Mertens, Christopher J; Meier, Matthias M; Brown, Steven; Norman, Ryan B; Xu, Xiaojing

    2013-10-01

    [1] The Nowcast of Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS) is a real-time, global, physics-based model used to assess radiation exposure to commercial aircrews and passengers. The model is a free-running physics-based model in the sense that there are no adjustment factors applied to nudge the model into agreement with measurements. The model predicts dosimetric quantities in the atmosphere from both galactic cosmic rays (GCR) and solar energetic particles, including the response of the geomagnetic field to interplanetary dynamical processes and its subsequent influence on atmospheric dose. The focus of this paper is on atmospheric GCR exposure during geomagnetically quiet conditions, with three main objectives. First, provide detailed descriptions of the NAIRAS GCR transport and dosimetry methodologies. Second, present a climatology of effective dose and ambient dose equivalent rates at typical commercial airline altitudes representative of solar cycle maximum and solar cycle minimum conditions and spanning the full range of geomagnetic cutoff rigidities. Third, conduct an initial validation of the NAIRAS model by comparing predictions of ambient dose equivalent rates with tabulated reference measurement data and recent aircraft radiation measurements taken in 2008 during the minimum between solar cycle 23 and solar cycle 24. By applying the criterion of the International Commission on Radiation Units and Measurements (ICRU) on acceptable levels of aircraft radiation dose uncertainty for ambient dose equivalent greater than or equal to an annual dose of 1 mSv, the NAIRAS model is within 25% of the measured data, which fall within the ICRU acceptable uncertainty limit of 30%. The NAIRAS model predictions of ambient dose equivalent rate are generally within 50% of the measured data for any single-point comparison. The largest differences occur at low latitudes and high cutoffs, where the radiation dose level is low. Nevertheless, analysis

  7. NAIRAS aircraft radiation model development, dose climatology, and initial validation

    Science.gov (United States)

    Mertens, Christopher J.; Meier, Matthias M.; Brown, Steven; Norman, Ryan B.; Xu, Xiaojing

    2013-10-01

    The Nowcast of Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS) is a real-time, global, physics-based model used to assess radiation exposure to commercial aircrews and passengers. The model is a free-running physics-based model in the sense that there are no adjustment factors applied to nudge the model into agreement with measurements. The model predicts dosimetric quantities in the atmosphere from both galactic cosmic rays (GCR) and solar energetic particles, including the response of the geomagnetic field to interplanetary dynamical processes and its subsequent influence on atmospheric dose. The focus of this paper is on atmospheric GCR exposure during geomagnetically quiet conditions, with three main objectives. First, provide detailed descriptions of the NAIRAS GCR transport and dosimetry methodologies. Second, present a climatology of effective dose and ambient dose equivalent rates at typical commercial airline altitudes representative of solar cycle maximum and solar cycle minimum conditions and spanning the full range of geomagnetic cutoff rigidities. Third, conduct an initial validation of the NAIRAS model by comparing predictions of ambient dose equivalent rates with tabulated reference measurement data and recent aircraft radiation measurements taken in 2008 during the minimum between solar cycle 23 and solar cycle 24. By applying the criterion of the International Commission on Radiation Units and Measurements (ICRU) on acceptable levels of aircraft radiation dose uncertainty for ambient dose equivalent greater than or equal to an annual dose of 1 mSv, the NAIRAS model is within 25% of the measured data, which fall within the ICRU acceptable uncertainty limit of 30%. The NAIRAS model predictions of ambient dose equivalent rate are generally within 50% of the measured data for any single-point comparison. The largest differences occur at low latitudes and high cutoffs, where the radiation dose level is low. Nevertheless, analysis suggests

  8. An engagement factor for caregiver radiation dose assessment with radioiodine treatment

    International Nuclear Information System (INIS)

    Lee, Hyun Kuk; Hong, Seong Jong; Jeong, Kyu Hwan; Jung, Jae Won; Kim, Seong Min; Kang, Yun-Hee; Han, Man Seok

    2015-01-01

    This study aims to suggest ways to better manage thyroid cancer patients treated with high- and low-activity radioiodine ( 131 I) by assessing external radiation doses to family members and caregivers and the level of radiation in the surrounding environment. The radiation doses to caregivers of 33 inpatients (who were quarantined in the hospital for 2-3 d after treatment) and 31 outpatients who received radioiodine treatment after thyroidectomy were measured using passive thermoluminescence dosemeters. In this study, 33 inpatients were administered high-activity (100-200 mCi) 131 I, and 31 outpatients were administered low-activity (30 mCi) 131 I. The average doses to caregivers were measured at 0.61 mSv for outpatients and 0.16 mSv for inpatients. The total integrated dose of the recovery (recuperation) rooms where the patients stayed after release from hospital was measured to be 0.83 mSv for outpatients and 0.23 mSv for inpatients. To reflect the degree of engagement between the caregiver and the patient, considering the duration and distance between two during exposure, the authors used the engagement factor introduced by Jeong et al. (Estimation of external radiation dose to caregivers of patients treated with radioiodine after thyroidectomy. Health Phys 2014;106:466-474.). This study presents a new engagement factor (K-value) of 0.82 obtained from the radiation doses to caregivers of both in- and out-patients treated with high- and low-activity radioiodine, and based on this new value, this study presented a new predicted dose for caregivers. A patient treated with high-activity radioiodine can be released after 24 h of isolation, whereas outpatients treated with low-activity radioiodine should be isolated for at least 12 h. (authors)

  9. Distribution of 226Ra and 228Ra in drinking water and dose assessment

    International Nuclear Information System (INIS)

    Ajay Kumar; Sugandhi, S.; Usha, N.; Rupali, K.; Gurg, R.P.

    2002-01-01

    The radioactivity concentrations of 226 Ra and 228 Ra have been analysed in 123 drinking water samples received from different regions of India. The maximum concentrations of 226 Ra and 228 Ra in drinking water are 8 mBq/l and 11.5 mBq/l respectively. The higher doses due to intake of 228 Ra through drinking water suggests that 228 Ra should also be measured in the assessment of ingestion dose to the population. The estimated committed effective doses range from 0.082 to 2.45 μSv/year and from 1.53 to 8.81 μSv/year for the ingestion of 226 Ra and 228 Ra respectively. (author)

  10. Problems Concerning Dose Assessments in Epidemiology of High Background Radiation Areas of Yangjiang, China (invited paper)

    International Nuclear Information System (INIS)

    Wei, L.X.; Yuan, Y.L.

    1998-01-01

    The purpose of this study on radiation levels and dose assessments in the epidemiology of a high background radiation area (HBRA) and the control area (CA) is to respond to the needs of epidemiology in these areas, where the inhabitants are continuously exposed to low dose, low dose rate ionising radiation. A brief description is given of how the research group evaluated the feasibility of the investigation by analysing the population size and the radiation levels, how simple reliable methods were used to get the individual annual dose for every cohort member, and how the cohort members were classified into various dose groups for dose-effect relationship analysis. Finally, the use of dose group classification for cancer mortality studies is described. (author)

  11. Dose assessments for Greifswald and Cadarache with updated source terms from ITER NSSR-2

    International Nuclear Information System (INIS)

    Raskob, W.; Hasemann, I.

    1998-08-01

    The International Thermonuclear Experimental Reactor ITER is in its late engineering phase. One of the most important safety aspects - in particular for achieving public acceptance - is to assure that the releases of harzardous material are minimal during normal operation and for accidental events, even if very unlikely. To this purpose probabilistic dose assessments for accidental atmospheric releases of various ITER source terms which contain tritium and/or activation products were performed for the sites of Greifswald, Germany, and Cadarache, France. In addition, routine releases into the atmosphere and hydrosphere have been evaluated. No country specific rules were applied and the input parameters were adapted as far as possible to those used within former studies to achieve a better comparability with site independent dose assessments performed in the frame of ITER. The calculations were based on source terms which, for the first time, contain a combination of tritium and activation products. This allowed a better judgment of the contribution to the total dose of the individual fusion relevant materials. The results were compared to site independent dose limits defined in the frame of ITER. Annual doses from routine releases (CAT-I) are below 0.1 μSv for the aquatic scenarios and are close to 1 μSv for the atmospheric source terms. Source terms for two different categories of accidental releases, representing 'extremely unlikely events' (CAT-IV) and 'hypothetical sequences' (CAT-V), were investigated. In none of these cases, the release scenarios of category CAT-IV exceed the ITER limits. In addition, relevant characteristic quantities of the early dose distribution from the hypothetical scenarios of type CAT-V are still below 50 mSv or 100 mSv, values which are commonly used as lower reference values for evacuation in many potential home countries of ITER. These site specific assessments confirmed that the proposed release limits and thus the derived dose

  12. A dose assessment for a U.S. nuclear test site -- Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Bogen, K.T.; Conrado, C.L.

    1993-07-01

    On March 1, 1954, a nuclear weapon test, code-named BRAVO, conducted at Bikini Atoll in the northern Marshall Islands contaminated the major residence island. Here the authors provide a radiological dose assessment for the main residence island, Bikini, using extensive radionuclide concentration data derived from analysis of food crops, ground water, cistern water, fish and other marine species, animals, air, and soil collected at Bikini Island. The unique composition of coral soil greatly alters the relative contribution of cesium-137 and strontium-90 to the total estimated dose relative to expectations based on North American and European soils. Cesium-137 produces 96% of the estimated dose for returning residents, mostly through uptake from the soil to terrestrial food crops but also from external gamma exposure. The estimated maximum annual effective dose is 4.4 mSv y -1 when imported foods, which are now an established part of the diet, are available. The 30-, 50-, and 70-y integral effective doses are 10 cSv, 14 cSv, and 16 cSv, respectively. An analysis of interindividual variability in 0- to 30-y expected integral dose indicates that 95% of Bikini residents would have expected doses within a factor of 3.4 above and 4.8 below the population-average value. A corresponding uncertainty analysis showed that after about 5 y of residence, the 95% confidence limits on population-average dose would be ±35% of its expected value. The authors have evaluated various countermeasures to reduce 137 Cs in food crops. Treatment with potassium reduces the uptake of 137 Cs into food crops, and therefore the ingestion dose, to less than 10% of pretreatment levels and has essentially no negative environmental consequences

  13. Development of personal dose monitoring system using wireless data transmission device

    International Nuclear Information System (INIS)

    Inui, Daisuke; Nakashima, Sadao

    2008-01-01

    Radiation workers working in radiation controlled area in nuclear power plants etc., are required to carry a dosimeters by regulation law. The workers are controlled daily on personal exposure dose by reading out the exposure dose information of the dosimeters with an area access control gate installed at the entrance of the radiation controlled area. This type of personal dose monitoring system has a problem that each worker can get his personal dose data only at the entrance of the radiation controlled area several times a day. We developed a system to get the real-time acquisition of personal dose data especially for workers working in a high dose area. This system is generally composed of a dosimeter with a wireless attachment, relay station, and monitor. Some relay stations set in main work places in the radiation controlled area can collect real-time personal dose data of each dosimeter carried by workers at the work place with the relay stations, and transmit it to the monitor to get personal dose data of individual workers. A wireless communication system between dosimeters and relay stations is applied to collect efficiently all personal dose data in the work place. (author)

  14. Assessment of regional pediatric computed tomography dose indices in Tamil Nadu

    OpenAIRE

    A Saravanakumar; K Vaideki; K N Govindarajan; S Jayakumar; B Devanand

    2017-01-01

    The aim of this article is to assess Tamil Nadu pediatric computed tomography (CT) diagnostic reference levels (DRLs) by collecting radiation dose data for the most commonly performed CT examinations. This work was performed for thirty CT scanners installed in various parts of the Tamil Nadu region. The patient cohort was divided into two age groups:

  15. Evaluation of doses from radiodiagnostic procedures performed in veterinary medicine and assessing of the doses of secondary radiation in the medical staff and animal owners

    International Nuclear Information System (INIS)

    Veneziani, Glauco Rogerio

    2012-01-01

    The primary goal in veterinary radiography is to produce radiographs of diagnostic quality on the first attempt. This goal serves three purposes: (1) to decrease radiation exposure to the patient and veterinary personnel; (2) to decrease the cost of the study for the client; and (3) to produce diagnostic data for rapid interpretation and treatment of the patient. This work aimed to determine the doses in dogs submitted to chest and abdomen X rays using the technique of thermoluminescence (TL) dosimetry. The radiation doses were assessed using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO 4 :Dy) and lithium fluoride doped with magnesium and titanium (LiF:Mg,Ti). The obtained results indicate that is extremely important the assessment of radiation doses involved in veterinary diagnostic radiology procedures, to evaluate the delivered doses to the animals, to be used as a parameter in the individual monitoring of pet's owners, who assist the animal positioning, and to protect occupationally exposed workers at the Veterinary Radiology Clinics. (author)

  16. Outdoor solar UVA dose assessment with EBT2 radiochromic film using spectrophotometer and densitometer measurements

    International Nuclear Information System (INIS)

    Abukassem, I.; Bero, M.A.

    2015-01-01

    Direct measurements of solar ultraviolet radiations (UVRs) have an important role in the protection of humans against UVR hazard. This work presents simple technique based on the application of EBT2 GAFCHROMIC R film for direct solar UVA dose assessment. It demonstrates the effects of different parts of the solar spectrum (UVB, visible and infrared) on performed UVA field measurements and presents the measurement uncertainty budget. The gradient of sunlight exposure level permitted the authors to establish the mathematical relationships between the measured solar UVA dose and two measured quantities: the first was the changes in spectral absorbance at the wavelength 633 nm (A 633 ) and the second was the optical density (OD). The established standard relations were also applied to calculate the solar UVA dose variations during the whole day; 15 min of exposure each hour between 8:00 and 17:00 was recorded. Results show that both applied experimental methods, spectrophotometer absorbance and densitometer OD, deliver comparable figures for EBT2 solar UVA dose assessment with relative uncertainty of 11 % for spectral absorbance measurements and 15 % for OD measurements. (authors)

  17. Assessment of fetal radiation dose to patients and staff in diagnostic radiology

    International Nuclear Information System (INIS)

    Osei, E.K.

    2000-07-01

    A major source of uncertainty in the estimation of fetal absorbed radiation dose is the influence of fetal size and position as these change with gestational age. Consequently, dose to the fetus is related to gestational age. Most studies of fetal dose estimation during pregnancy assume that the uterus dose is equal to fetal dose. These dose estimates do not take account of gestational age and individual fetal depth, factors which are significant when calculating dose. To establish both positional and size data for estimation of fetal absorbed dose from radiological examinations, the depths from the mother's anterior surface to the mid-line of the fetal head and abdomen were measured from ultrasound scans in 215 pregnant women. Depths were measured along a ray path projected in the anterior-posterior direction from the mother's abdomen. The fetal size was estimated from measurements of the fetal abdominal and head circumference, femur length and the biparietal diameter. The effects of fetal presentation, maternal bladder volume, placenta location, gestational age and maternal AP thickness on fetal depth and size were analysed. A Monte Carlo (MC) model was developed, and used to derive factors for converting dose-area product and free-in-air entrance surface dose from medical exposure of a pregnant patient to absorbed dose to the uterus/embryo, and for converting uterus dose to fetal dose in the later stages of pregnancy. Also presented are factors for converting thermoluminescence dosimeter reading from occupational exposure of a pregnant worker to equivalent dose to the fetus. The MC model was verified experimentally by direct measurement of uterus depth dose in a female Rando phantom, and also by comparison with other experimental work and MC results in the literature. The application of the various conversion factors is demonstrated by a review of the dose estimation process in 50 cases of fetal irradiation from medical exposures. (author)

  18. Maximum skin dose assessment in interventional cardiology: large area detectors and calculation methods

    International Nuclear Information System (INIS)

    Quail, E.; Petersol, A.

    2002-01-01

    Advances in imaging technology have facilitated the development of increasingly complex radiological procedures for interventional radiology. Such interventional procedures can involve significant patient exposure, although often represent alternatives to more hazardous surgery or are the sole method for treatment. Interventional radiology is already an established part of mainstream medicine and is likely to expand further with the continuing development and adoption of new procedures. Between all medical exposures, interventional radiology is first of the list of the more expansive radiological practice in terms of effective dose per examination with a mean value of 20 mSv. Currently interventional radiology contribute 4% to the annual collective dose, in spite of contributing to total annual frequency only 0.3% but considering the perspectives of this method can be expected a large expansion of this value. In IR procedures the potential for deterministic effects on the skin is a risk to be taken into account together with stochastic long term risk. Indeed, the International Commission on Radiological Protection (ICRP) in its publication No 85, affirms that the patient dose of priority concern is the absorbed dose in the area of skin that receives the maximum dose during an interventional procedure. For the mentioned reasons, in IR it is important to give to practitioners information on the dose received by the skin of the patient during the procedure. In this paper maximum local skin dose (MSD) is called the absorbed dose in the area of skin receiving the maximum dose during an interventional procedure

  19. ERUPTION TO DOSE: COUPLING A TEPHRA DISPERSAL MODEL WITHIN A PERFORMANCE ASSESSMENT FRAMEWORK

    International Nuclear Information System (INIS)

    G. N. Keating, J. Pelletier

    2005-01-01

    The tephra dispersal model used by the Yucca Mountain Project (YMP) to evaluate the potential consequences of a volcanic eruption through the waste repository must incorporate simplifications in order to function within a large Monte-Carlo style performance assessment framework. That is, the explicit physics of the conduit, vent, and eruption column processes are abstracted to a 2-D, steady-state advection-dispersion model (ASHPLUME) that can be run quickly over thousands of realizations of the overall system model. Given the continuous development of tephra dispersal modeling techniques in the last few years, we evaluated the adequacy of this simplified model for its intended purpose within the YMP total system performance assessment (TSPA) model. We evaluated uncertainties inherent in model simplifications including (1) instantaneous, steady-state vs. unsteady eruption, which affects column height, (2) constant wind conditions, and (3) power-law distribution of the tephra blanket; comparisons were made to other models and published ash distributions. Spatial statistics are useful for evaluating differences in these model output vs. results using more complex wind, column height, and tephra deposition patterns. However, in order to assess the adequacy of the model for its intended use in TSPA, we evaluated the propagation of these uncertainties through FAR, the YMP ash redistribution model, which utilizes ASHPLUME tephra deposition results to calculate the concentration of nuclear waste-contaminated tephra at a dose-receptor population as a result of sedimentary transport and mixing processes on the landscape. Questions we sought to answer include: (1) what conditions of unsteadiness, wind variability, or departure from simplified tephra distribution result in significant effects on waste concentration (related to dose calculated for the receptor population)? (2) What criteria can be established for the adequacy of a tephra dispersal model within the TSPA

  20. Intravascular ultrasound based dose assessment in endovascular brachytherapy

    International Nuclear Information System (INIS)

    Catalano, Gianpiero; Tamburini, Vittorio; Colombo, Antonio; Nishida, Takahiro; Parisi, Giovanni; Mazzetta, Chiara; Orecchia, Roberto

    2003-01-01

    Background: the role of endovascular brachytherapy in restenosis prevention is well documented. Dose is usually prescribed at a fixed distance from the source axis by angiographic quantification of vessel diameter. Recently, intravascular ultrasound (IVUS) was introduced in dose prescription, allowing a better evaluation of the vessel anatomy. This study retrospectively explores the difference between prescription following angiographic vessel sizing and delivered dose calculated with IVUS. Methods and results: Seventeen lesions were studied with IVUS, identifying on irradiated segment, three sections on which measuring minimal and maximal distance from the centre of IVUS catheter to the adventitia; using dedicated software, corresponding doses were calculated. The dose ranged widely, with maximal and minimal values of 71.6 and 4.9 Gy; furthermore, heterogeneity in dose among different sections was observed. In the central section, the maximal dose was 206% of the one prescribed with the QCA model at 2 mm from the source axis, while the minimal dose was 96%. In proximal and distal sections, respective values were 182, 45, 243, and 122%. Conclusions: Our analysis confirmed the dose inhomogeneity delivered with an angiographic fixed-dose prescription strategy. A dose variation was found along the irradiated segment due to the differences in vessel thickness. IVUS emerged as an important tool in endovascular brachytherapy, especially for irregular-shaped vessels

  1. Expected dose for the early failure scenario classes in the 2008 performance assessment for the proposed high-level radioactive waste repository at Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Helton, J.C.; Hansen, C.W.; Sallaberry, C.J.

    2014-01-01

    Extensive work has been carried out by the U.S. Department of Energy (DOE) in the development of a proposed geologic repository at Yucca Mountain (YM), Nevada, for the disposal of high-level radioactive waste. In support of this development and an associated license application to the U.S. Nuclear Regulatory Commission (NRC), the DOE completed an extensive performance assessment (PA) for the proposed YM repository in 2008. This presentation describes the determination of expected dose to the reasonably maximally exposed individual (RMEI) specified in the NRC regulations for the YM repository for the early waste package (WP) failure scenario class and the early drip shield (DS) failure scenario class in the 2008 YM PA. The following topics are addressed: (i) properties of the early failure scenario classes and the determination of dose and expected dose the RMEI, (ii) expected dose and uncertainty in expected dose to the RMEI from the early WP failure scenario class, (iii) expected dose and uncertainty in expected dose to the RMEI from the early DS failure scenario class, (iv) expected dose and uncertainty in expected dose to the RMEI from the combined early WP and early DS failure scenario class with and without the inclusion of failures resulting from nominal processes, and (v) uncertainty in the occurrence of early failure scenario classes. The present article is part of a special issue of Reliability Engineering and System Safety devoted to the 2008 YM PA; additional articles in the issue describe other aspects of the 2008 YM PA. - Highlights: • Extensive work has been carried out by the U.S. DOE in the development of a proposed geologic repository at Yucca Mountain (YM), Nevada, for the disposal of high-level radioactive waste. • Properties of the early failure scenario classes (i.e. early waste package failure and early drip shield failure) in the 2008 YM performance assessment are described. • Determination of dose, expected dose and expected (mean

  2. X-rays individual dose assessment using TLD dosimeters

    International Nuclear Information System (INIS)

    Salas, Carlos

    2008-01-01

    This paper describes the methodology used in Embalse NPP for measuring individual X-ray dose in dentists and radiologists, who work in areas near the plant. Personnel is provided with TLD personal dosimeters for thoracic use, as well as TLD ring dosimeters. This individual X-ray dosimetry is fundamental in order to know the effective energy coming from the radiation field, since the dosimetry factors depend on it. On the other hand, the response of the TLD crystals also depends of the effective energy; this accentuates the problem when assessing the individual dose. The X-ray dosimeter must simultaneously determine the value of the effective energy and the corresponding dose value. The basic principle for determining effective energy is by using at least two different TLD materials covered by filters of different thickness. The TLD materials used have totally energy responses. Therefore, different readouts from each of the crystals are obtained. The ratio between both readouts provides a factor that depends of the effective energy but that is 'independent' from the exposure values irradiated to the dosimeter. The Personal TLD dosimeter currently in use is Bicron-Harshaw. It comprises a carrier model 8807. This carrier contains a card model 2211 which groups two TLD 200 crystals and two TLD 100 crystals. It has internal filters at each side of the TLD 200 crystals. The periodical calibration of these dosimeters consists in the irradiation of some dosimeters with different X-ray energy beams in the National Atomic Energy Commission (CNEA). This dosimeter was used, by the National Regulatory Authority (ARN) in several comparisons, always getting satisfactory results. (author)

  3. Dose assessment for decontamination in Goiania

    International Nuclear Information System (INIS)

    Amaral, E.C.S.

    2000-01-01

    Shortly after the accident at Goiania, the need arose to set derived intervention levels for the various exposure pathways to guide and optimise clean up measures. For the members of the critical group an intervention level of 5 mSv for the total effective dose in the first year after the accident was chosen, which then was subdivided into values of 1 mSv due to the contribution of external irradiation indoors, 3 mSv from external irradiation while being outdoors, and 1 mSv due to incorporation of resuspended particles and ingestion of locally produced food. The clean up indoors could be directed such that a pre-described ambient dose rate was no longer exceeded. These exposure levels and effective doses to the critical groups predicted in 1988 are compared to actual measurements made in 1988 to 1993 in a local house near one primary contamination foci, and best estimate. It can be shown that the actual doses received by members of the public living in the affected areas were significantly lower. The various reasons for this overprediction will be discussed. (author)

  4. Assessment of pediatrics radiation dose from routine x-ray ...

    African Journals Online (AJOL)

    Background: Given the fact that children are more sensitive to ionizing radiation than adults,with an increased risk of developing radiation-induced cancer,special care should be taken when they undergo X-ray examinations. The main aim of the current study was to determine Entrance Surface Dose (ESD) to pediatric ...

  5. Probabilistic Dose Assessment from SB-LOCA Accident in Ujung Lemahabang Using TMI-2 Source Term

    Directory of Open Access Journals (Sweden)

    Sunarko

    2017-01-01

    Full Text Available Probabilistic dose assessment and mapping for nuclear accident condition are performed for Ujung Lemahabang site in Muria Peninsula region in Indonesia. Source term is obtained from Three-Mile Island unit 2 (TMI-2 PWR-type SB-LOCA reactor accident inverse modeling. Effluent consisted of Xe-133, Kr-88, I-131, and Cs-137 released from a 50 m stack. Lagrangian Particle Dispersion Method (LPDM and 3-dimensional mass-consistent wind field are employed to obtain surface-level time-integrated air concentration and spatial distribution of ground-level total dose in dry condition. Site-specific meteorological data is obtained from hourly records obtained during the Site Feasibility Study period in Ujung Lemahabang. Effluent is released from a height of 50 meters in uniform rate during a 6-hour period and the dose is integrated during this period in a neutrally stable atmospheric condition. Maximum dose noted is below regulatory limit of 1 mSv and radioactive plume is spread mostly to the W-SW inland and to N-NE from the proposed plant to Java Sea. This paper has demonstrated for the first time a probabilistic analysis method for assessing possible spatial dose distribution, a hypothetical release, and a set of meteorological data for Ujung Lemahabang region.

  6. Low-dose radiation epidemiological studies: an assessment of methodological problems

    International Nuclear Information System (INIS)

    Modan, B.

    1991-01-01

    The present report attempts to assess the problems inherent in the analysis of low dose radiation studies, with emphasis on possible sources of methodological errors in the published data, and the consequent relevance to risk estimates. The published data examined concerned populations exposed to nuclear sources such as fallout, weapons' test or in the vicinity of nuclear reactors, occupational exposure, intra-uterine diagnostic X-rays, scattered radiation following X-ray therapy and background irradiation. (UK)

  7. Monitoring and assessment of individual doses of occupationally exposed workers due to external radiation

    International Nuclear Information System (INIS)

    Kitaw, S. T.

    2015-05-01

    Exposure to external radiation occurs in many occupations. Any exposure to ionizing radiation has the tendency to change the biochemical make-up of the human body which may result in biological health effects of ionizing radiation. This study reviews the monitoring and assessment of external radiation doses in industrial radiography using thermoluminescence and direct reading dosimeters. Poor handling procedures such as inadequate engineering control of equipment, safety culture, management, and inadequate assessment and monitoring of doses are the causes of most of the reported cases of exposure to external radiation in industrial radiography. Occupational exposure data in industrial radiography from UNSCEAR report 2008 was discussed and recommendations were made to regulatory authorities, operating organizations and radiographers. (au)

  8. Equivalent dose, effective dose and risk assessment from cephalometric radiography to critical organs

    International Nuclear Information System (INIS)

    Kang, Seong Sook; Cho, Bon Hae; Kim, Hyun Ja

    1995-01-01

    In head and neck region, the critical organ and tissue doses were determined, and the risks were estimated from lateral, posteroanterial and basilar cephalometric radiography. For each cephalometric radiography, 31 TLDs were placed in selected sites (18 internal and 13 external sites) in a tissue-equivalent phantom and exposed, then read-out in the TLD reader. The following results were obtained; 1. From lateral cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland (3.6 μSv) and the next highest dose was that received by the bone marrow (3 μSv). 2. From posteroanterial cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland (2 μSv) and the next highest dose was that received by the bone marrow (1.8 μSv). 3. From basilar cephalometric radiography, the highest effective dose recorded was that delivered to the thyroid gland (31.4 μSv) and the next highest dose was that received by the salivary gland (13.3 μSv). 4. The probabilities of stochastic effect from lateral, posteroanterial and basilar cephalometric radiography were 0.72 X 10 -6 , 0.49 X 10 -6 and 3.51 X 10 -6 , respectively.

  9. Diffuse and fugitive emission dose assessment on the Hanford Site

    International Nuclear Information System (INIS)

    Davis, W.E.; Schmidt, J.W.; Gleckler, B.P.; Rhoads, K.

    1995-01-01

    On February 3, 1993, the US Department of Energy, Richland Operations Office (RL), received a Compliance Order and Information Request from the Director of the Air and Toxics Division of the US Environmental Protection Agency (EPA), Region 10. The Compliance Order requires RL to (1) evaluate all radionuclide emission points at the Hanford Site to determine which are subject to continuous emission measurement requirements in 40 Code of Federal Regulations (CFR) 61, Subpart H, and (2) continuously measure radionuclide emissions in accordance with 40 CFR 61.93. The Information Request requires RL to provide a written Compliance Plan to meet the requirements of the Compliance Order. The RL Compliance Plan included as one of its milestones the requirement to develop a Federal Facility Compliance Agreement (FFCA). An FFCA was negotiated between RL and the EPA, Region 10, and was entered into on February 7, 1994. One of the milestones was to provide EPA, Region 10, with a copy of the Federal Clean Air Act Title V operating air permit application and Air Emission Inventory (AEI) concurrent with its submission to the Washington State Department of Ecology. The AEI will include an assessment of the diffuse and fugitive emissions from the Hanford Site. This assessment does not identify any diffuse or fugitive emission source that would cause an effective dose equivalent greater than 0.1 mrem/yr

  10. Development of a computational methodology for internal dose calculations

    International Nuclear Information System (INIS)

    Yoriyaz, Helio

    2000-01-01

    A new approach for calculating internal dose estimates was developed through the use of a more realistic computational model of the human body and a more precise tool for the radiation transport simulation. The present technique shows the capability to build a patient-specific phantom with tomography data (a voxel-based phantom) for the simulation of radiation transport and energy deposition using Monte Carlo methods such as in the MCNP-4B code. In order to utilize the segmented human anatomy as a computational model for the simulation of radiation transport, an interface program, SCMS, was developed to build the geometric configurations for the phantom through the use of tomographic images. This procedure allows to calculate not only average dose values but also spatial distribution of dose in regions of interest. With the present methodology absorbed fractions for photons and electrons in various organs of the Zubal segmented phantom were calculated and compared to those reported for the mathematical phantoms of Snyder and Cristy-Eckerman. Although the differences in the organ's geometry between the phantoms are quite evident, the results demonstrate small discrepancies, however, in some cases, considerable discrepancies were found due to two major causes: differences in the organ masses between the phantoms and the occurrence of organ overlap in the Zubal segmented phantom, which is not considered in the mathematical phantom. This effect was quite evident for organ cross-irradiation from electrons. With the determination of spatial dose distribution it was demonstrated the possibility of evaluation of more detailed doses data than those obtained in conventional methods, which will give important information for the clinical analysis in therapeutic procedures and in radiobiologic studies of the human body. (author)

  11. The Dose Assessment in the Vault Test Case of Near-Surface Disposal Facility for Drinking Water Scenario

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyoung; Choi, Byung Seon; Moon, Jei Kwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Jae Woo [Jeju National University, Jeju (Korea, Republic of)

    2012-05-15

    It is generally accepted that the radionuclides contained in the radioactive wastes will be eventually released and these will be transported to the accessible environment (near-field, far-field, biosphere). Therefore, the long-term safety assessment of near-surface radioactive waste disposal should be required by modeling the expected release of radionuclides from the repository, far-field area, and biosphere. Finally, the effective dose rate should be estimated through the released radionuclides. In this study, the radiological dose was evaluated for the reference near-surface radioactive waste disposal facility in Vaalputs, South Africa, which has been selected as a part of IAEA coordinated research program on improvement of safety assessment methodologies(ISAM). The assessment of radiological dose was performed for drinking water scenario from a well. The release and transport of radionuclides in disposal system were simulated by GoldSim. This approach suggested the time variation of effective dose over long-term period. And the results from this approach were compared with another approach method for the same facility and scenario

  12. The Dose Assessment in the Vault Test Case of Near-Surface Disposal Facility for Drinking Water Scenario

    International Nuclear Information System (INIS)

    Kim, Tae Hyoung; Choi, Byung Seon; Moon, Jei Kwon; Park, Jae Woo

    2012-01-01

    It is generally accepted that the radionuclides contained in the radioactive wastes will be eventually released and these will be transported to the accessible environment (near-field, far-field, biosphere). Therefore, the long-term safety assessment of near-surface radioactive waste disposal should be required by modeling the expected release of radionuclides from the repository, far-field area, and biosphere. Finally, the effective dose rate should be estimated through the released radionuclides. In this study, the radiological dose was evaluated for the reference near-surface radioactive waste disposal facility in Vaalputs, South Africa, which has been selected as a part of IAEA coordinated research program on improvement of safety assessment methodologies(ISAM). The assessment of radiological dose was performed for drinking water scenario from a well. The release and transport of radionuclides in disposal system were simulated by GoldSim. This approach suggested the time variation of effective dose over long-term period. And the results from this approach were compared with another approach method for the same facility and scenario

  13. Human health risk assessment (HHRA) for environmental development and transfer of antibiotic resistance

    DEFF Research Database (Denmark)

    Ashbolt, Nicholas J.; Amézquita, Alejandro; Backhaus, Thomas

    2013-01-01

    to enable human health risk assessments (HHRA) that focus on the role of the environment in the failure of antibiotic treatment caused by antibiotic-resistant pathogens. Methods: The authors participated in a workshop held 4-8 March 2012 in Québec, Canada, to define the scope and objectives...... of an environmental assessment of antibiotic-resistance risks to human health. We focused on key elements of environmental-resistance-development "hot spots," exposure assessment (unrelated to food), and dose response to characterize risks that may improve antibiotic-resistance management options. Discussion: Various...... novel aspects to traditional risk assessments were identified to enable an assessment of environmental antibiotic resistance. These include a) accounting for an added selective pressure on the environmental resistome that, over time, allows for development of antibiotic-resistant bacteria (ARB); b...

  14. Mayak Film Dosimeter Response Studies Part III: Application to Worker Dose Assessment

    International Nuclear Information System (INIS)

    Smetanin, Mikhail; Vasilenko, E. K.; Scherpelz, Robert I.

    2007-01-01

    This paper describes the methods used to convert individual dosimeter readings for workers to obtain estimates of worker doses received in Mayak facilities. Film dosimeters were used at Mayak PA for worker monitoring from 1948 until 1992. The method requires a determination of the relationship between the absorbed dose in film emulsion and the dose in air under calibration conditions, then an extension of this relationship to exposures in the actual radiation fields of the workplace. Corrections needed to account for actual workplace exposure conditions were determined by modeling with the Monte-Carlo radiation transport computer code MCNP. Correction factors were developed to convert from dosimeter reading to a realistic worker dose. The method was applied as a basis for individual dose reconstruction using film dosimeters in realistic photon spectra and geometries at Mayak PA work areas

  15. 'Reasonable' regulation of low doses in the Netherlands?

    International Nuclear Information System (INIS)

    Zuur, Ciska

    2002-01-01

    As long as it is not clear exactly what the risks of low doses are, exposures should be regulated to be 'as low as reasonably achievable' (ALARA). In radiation protection, for normal situations, this means that a projected dose reduction can only be obligatory when the efforts needed to achieve the reduction are 'reasonable' in comparison with it, economical and social aspects being taken into account. In the recent Dutch regulations, 'reasonable' values have been established for the relevant parameters used in the ALARA concept and the paper discusses the values required to calculate the doses for the critical group due to a source. In some cases, the effort expended in making the ALARA dose assessments might not be reasonable in comparison with the dose reduction to be expected. The system which has been developed in the Netherlands to avoid these 'unreasonable' dose calculations, measurements and assessments is explained. (author)

  16. Dose assessment in pediatric computerized tomography; Avaliacao de doses em tomografia computadorizada pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Vilarinho, Luisa Maria Auredine Lima

    2004-07-01

    The objective of this work was the evaluation of radiation doses in paediatric computed tomography scans, considering the high doses usually involved and the absence of any previous evaluation in Brazil. Dose values were determined for skull and abdomen examinations, for different age ranges, by using the radiographic techniques routinely used in the clinical centers investigated. Measurements were done using pencil shape ionization chambers inserted in polymethylmethacrylate (PMMA) phantoms. These were compact phantoms of different diameters were specially designed and constructed for this work, which simulate different age ranges. Comparison of results with published values showed that doses were lower than the diagnostic reference levels established to adults exams by the European Commission. Nevertheless, doses in paediatric phantoms were higher than those obtained in adult phantoms. The paediatric dose values obtained in Hospitals A and B were lower than the reference level (DRL) adopted by SHIMPTON for different age ranges. In the range 0 - 0.5 year (neonatal), the values of DLP in Hospital B were 94 por cent superior to the DRL For the 10 years old children the values of CTDI{sub w} obtained were inferior in 89 por cent for skull and 83 por cent for abdomen examinations, compared to the values published by SHRIMPTON and WALL. Our measured CTDI{sub w} values were inferior to the values presented for SHRIMPTON and HUDA, for all the age ranges and types of examinations. It was observed that the normalized dose descriptors values in children in the neonatal range were always superior to the values of doses for the adult patient. In abdomen examinations, the difference was approximately 90% for the effective dose (E) and of 57%.for CTDI{sub w} . (author)

  17. Committed dose assessment based on background outdoor gamma exposure in Chihuahua City, Mexico

    International Nuclear Information System (INIS)

    Luevano G, S.; Perez T, A.; Pinedo A, C.; Renteria V, M.; Carrillo F, J.; Montero C, M. E.

    2015-10-01

    Full text: Determining ionizing radiation in a geographic area serves to assess its effects on populations health. The aim of this study was to evaluate the spatial distribution of the background environmental outdoor gamma dose rates in Chihuahua City. This study also estimated the committed dose and the lifetime cancer risks of the population of this city. To determine the outdoor gamma dose rate in air, annual effective dose, and the lifetime cancer risk, 48 sampling points were randomly selected along the Chihuahua City. Outdoor gamma dose rate measurements were carried out by using a Geiger-Muller counter. At the same sites, 48 soil samples were taken to obtain the activity concentrations of 226 Ra, 232 Th, 40 K and their terrestrial gamma dose rates. Radioisotope activity concentrations were determined by gamma spectrometry. Outdoor gamma dose rates ranged from 56 to 193 n Gy h -1 . Results indicated that lifetime effective dose to inhabitants of Chihuahua City is in average of 19.8 mSv, resulting in a lifetime cancer risk of 0.001. In addition, the mean of activity concentrations in soil were 51.8, 73.1, and 1096.5 Bq kg -1 , of 226 Ra, 232 Th and 40 K, respectively. From the analysis of the spatial distribution of 232 Th, 226 Ra, and 40 K is to north, to north-center, and to south of city, respectively. In conclusion, natural background gamma dose received by inhabitants of Chihuahua City is high and mainly due to geological characteristics of the zone. (Author)

  18. Phase I dose escalation pharmacokinetic assessment of intravenous humanized anti-MUC1 antibody AS1402 in patients with advanced breast cancer.

    Science.gov (United States)

    Pegram, Mark D; Borges, Virginia F; Ibrahim, Nuhad; Fuloria, Jyotsna; Shapiro, Charles; Perez, Susan; Wang, Karen; Schaedli Stark, Franziska; Courtenay Luck, Nigel

    2009-01-01

    MUC1 is a cell-surface glycoprotein that establishes a molecular barrier at the epithelial surface and engages in morphogenetic signal transduction. Alterations in MUC1 glycosylation accompany the development of cancer and influence cellular growth, differentiation, transformation, adhesion, invasion, and immune surveillance. A 20-amino-acid tandem repeat that forms the core protein of MUC1 is overexpressed and aberrantly glycosylated in the majority of epithelial tumors. AS1402 (formerly R1550) is a humanized IgG1k monoclonal antibody that binds to PDTR sequences within this tandem repeat that are not exposed in normal cells. AS1402 is a potent inducer of antibody-dependent cellular cytotoxicity (ADCC), specifically against MUC1-expressing tumor cells. The objective of this study was to determine the safety, tolerability, and pharmacokinetic (PK) characteristics of AS1402 monotherapy in patients with locally advanced or metastatic MUC1-positive breast cancer that had progressed after anthracyclines- and taxane-based therapy. Patients received AS1402 over a 1- to 3-hour intravenous (i.v.) infusion at doses between 1 and 16 mg/kg, with repeated dosing every 1 to 3 weeks (based on patient-individualized PK assessment) until disease progression. Serum AS1402 levels were measured at multiple times after i.v. administration. Human anti-human antibody (HAHA) responses were measured to determine the immunogenicity of AS1402. Noncompartmental pharmacokinetic parameters were determined and were used to assess dose dependency across the dose range studied. Twenty-six patients were treated. AS1402 was generally well tolerated. Two grade 3/4 drug-related adverse events were reported, both at the 3-mg/kg dose. Neither was observed in expanded or subsequent dosing cohorts. No anti-human antibodies were detected. Plasma concentrations of AS1402 appeared to be proportional to dose within the 1- to 16-mg/kg dose range assessed, with a mean terminal half-life of 115.4 +/- 37.1 hours

  19. Uncertainties in soil-plant interactions in advanced models for long-timescale dose assessment

    Energy Technology Data Exchange (ETDEWEB)

    Klos, R. [Aleksandria Sciences Ltd. (United Kingdom); Limer, L. [Limer Scientific Ltd. (United Kingdom); Perez-Sanchez, D. [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas - CIEMAT (Spain); Xu, S.; Andersson, P. [Swedish Radiation Safty Authority (Sweden)

    2014-07-01

    Traditional models for long-timescale dose assessment are generally conceptually straightforward, featuring one, two or three spatial compartments in the soil column and employing data based on annually averaged parameters for climate characteristics. The soil-plant system is usually modelled using concentration ratios. The justification for this approach is that the timescales relevant to the geologic disposal of radioactive waste are so long that simple conceptual models are necessary to account for the inherent uncertainties over the timescale of the dose assessment. In the past few years, attention has been given to more detailed 'advanced' models for use dose assessment that have a high degree of site-specific detail. These recognise more features, events and processes since they have higher spatial and temporal resolution. This modelling approach has been developed to account for redox sensitive radionuclides, variability of the water table position and accumulation in non-agricultural ecosystems prior to conversion to an agricultural ecosystem. The models feature higher spatial and temporal resolution in the soil column (up to ten layers with spatially varying k{sub d}s dependent on soil conditions) and monthly rather than annually averaged parameters. Soil-plant interaction is treated as a dynamic process, allowing for root uptake as a function of time and depth, according to the root profile. Uncertainty in dose assessment models associated with the treatment of prior accumulations in agricultural soils has demonstrated the importance of the model's representation of the soil-plant interaction. The treatment of root uptake as a dynamic process as opposed to a simple concentration ratio implies a potentially important difference despite the dynamic soil-plant transfer rate being based on established concentration ratio values. These discrepancies have also appeared in the results from the higher spatio-temporal resolution models. This paper

  20. Exposure dose assessment using bioassay

    International Nuclear Information System (INIS)

    Suga, Shinichi

    1994-01-01

    Bioassay involves following steps: sampling, pre-treatment, chemical separation and counting of radioactivity. As bioassay samples, urines are usually used, although faecal analysis may be required in some occasions for example to assess intake of non-transferable radioactive materials. Nasal smear is a useful indicator of an inhalation case. Exhalation air is used to estimate the intake of tritiated water. Sample pre-treatment includes evaporation for concentration, wet ashing, dry ashing and co-precipitation. After adding small amount of nitric acid, the sample can be concentrated by 1/10 of initial volume, which may be used to identify γ-emitters. As the pre-treatment of urine, wet ashing is used for example for analysis of Pu, and co-precipitation is used for example for analysis of Sr. Dry ashing by electric furnace is usually adopted for faecal samples. Methods of chemical separation depend on the radionuclide(s) to be analysed. The detection limit depends also on radionuclide, and for example typical detection limits are 0.4Bq / l (volume of urine sample) for 89 Sr or 90 Sr, and 0.01 Bq / l with urine and 0.01 Bq per sample with faeces for 238 Pu, 239 Pu or 241 Am. Simpler methods can be used for some radionuclides: For example, radioactivity concentration of tritium can be determined by liquid scintillation counting of urine or condensed water from exhaled air, and natural uranium in urine can be quantified by using fluorometric method. In some circumstances, gross-α or gross-β analyses are useful for quick estimation. To estimate intakes by inhalation or by ingestion from bioassay results and to assess the committed dose equivalent, commonly available bases are the relevant publications by the ICRP and domestic guides and manuals that conform to the radiation protection regulations. (author)

  1. Radiation Dose-Response Relationships and Risk Assessment

    International Nuclear Information System (INIS)

    Strom, Daniel J.

    2005-01-01

    The notion of a dose-response relationship was probably invented shortly after the discovery of poisons, the invention of alcoholic beverages, and the bringing of fire into a confined space in the forgotten depths of ancient prehistory. The amount of poison or medicine ingested can easily be observed to affect the behavior, health, or sickness outcome. Threshold effects, such as death, could be easily understood for intoxicants, medicine, and poisons. As Paracelsus (1493-1541), the 'father' of modern toxicology said, 'It is the dose that makes the poison.' Perhaps less obvious is the fact that implicit in such dose-response relationships is also the notion of dose rate. Usually, the dose is administered fairly acutely, in a single injection, pill, or swallow; a few puffs on a pipe; or a meal of eating or drinking. The same amount of intoxicants, medicine, or poisons administered over a week or month might have little or no observable effect. Thus, before the discovery of ionizing radiation in the late 19th century, toxicology ('the science of poisons') and pharmacology had deeply ingrained notions of dose-response relationships. This chapter demonstrates that the notion of a dose-response relationship for ionizing radiation is hopelessly simplistic from a scientific standpoint. While useful from a policy or regulatory standpoint, dose-response relationships cannot possibly convey enough information to describe the problem from a quantitative view of radiation biology, nor can they address societal values. Three sections of this chapter address the concepts, observations, and theories that contribute to the scientific input to the practice of managing risks from exposure to ionizing radiation. The presentation begins with irradiation regimes, followed by responses to high and low doses of ionizing radiation, and a discussion of how all of this can inform radiation risk management. The knowledge that is really needed for prediction of individual risk is presented

  2. Meteorological monitoring for environmental/dose assessment and emergency response modeling: How much is enough?

    International Nuclear Information System (INIS)

    Glantz, C.S.

    1989-01-01

    In evaluation the effectiveness and appropriateness of meteorological monitoring programs, managers responsible for planning and operating emergency response or environmental/dose assessment systems must routinely question whether enough meteorological data are being obtained to adequately support system applications. There is no simple answer or cookbook procedure that can be followed in generating an appropriate answer to this question. The answer must be developed through detailed consideration of the intended applications for the data, the capabilities of the models that would use the data, pollutant release characteristics, terrain in the modeling region, the size of the modeling domain, and the distribution of human population in the modeling domain. It is recommended that manager consult meteorologists when assessing these factors; the meteorologist's detailed knowledge of, and experience in, studying atmospheric transport and diffusion should assist the manager in determining the appropriate level of meteorological monitoring. 1 ref

  3. Developing a single-aliquot protocol for measuring equivalent dose in biogenic carbonates

    International Nuclear Information System (INIS)

    Stirling, R.J.; Duller, G.A.T.; Roberts, H.M.

    2012-01-01

    Exploiting biogenic carbonates as thermoluminescence dosimeters requires an understanding of trap kinetics and an appropriate sequence with which to measure equivalent dose. The trap kinetics of two high temperature peaks (peaks II and III) from calcitic snail opercula have been investigated resulting in the calculation of lifetimes of 7.4 × 10 7 and 1.4 × 10 11 years for the two peaks respectively. Two measurement sequences, based upon changes in the application and measurement of a test dose, have been applied to peaks II and III, and though both methods were equally successful in dose recovery and production of a dose response curve some differences were observed. Primarily, the use of method 1 lead to dose dependant sensitivity change implying competition effects occurring during irradiation; method 2 did not experience this phenomenon. As a consequence method 2 was chosen as the most appropriate protocol for single-aliquot dating of this material. When assessing the TL behaviour of the two peaks, peak II performed poorly in dose recovery experiments recovering a dose 60–100% larger than that applied. Disproportionate growth of peak II in response to a beta dose applied prior to measurement, compared to growth following regeneration doses indicated that peak II was not suitable for use in single-aliquot protocols. However, dose recovery results for peak III were all within errors of unity of the given dose, and peak III was therefore chosen as the most appropriate peak for TL dosimetry in these single-aliquot procedures. The lifetime of charge in peak III is sufficient to date over many millions of years, and furthermore using the chosen method 2 the dose response curve has a D 0 of 3,250 ± 163 Gy allowing dating to over 3 million years.

  4. Dose assessment of SiC nanoparticle dispersions during in vitro assays

    International Nuclear Information System (INIS)

    Mejia, Jorge; Piret, Jean-Pascal; Noël, Florence; Masereel, Bernard; Toussaint, Olivier; Lucas, Stéphane

    2013-01-01

    Here, we show that key physicochemical parameters of commercial Silicon Carbide nanoparticles, such as the primary particles of about 53 nm in size, the agglomerates size, and the surface composition, are considerably modified with respect to the pristine conditions, during in vitro assessment. The use of sample conditioning stages, such as the pre-dispersion in aqueous media and the subsequent dispersion in a culture medium specific to the in vitro assay, produce modifications as the absorption of N, C, and O, from the culture medium, in the nanoparticles surface. Our results show that the sedimented dose, fraction of sedimented NPs during incubation and consequently in contact with cells seeded at the bottom, of Silicon Carbide nanoparticles can be measured from the particle size distribution obtained using a centrifugal liquid sedimentation technique. It is underlined that the variations observed in the physicochemical properties are related to the in vitro assay conditions. Culture medium and incubation time are found to influence the most the sedimented dose and consequently the cells dose uptake

  5. A comprehensive approach to benefit-risk assessment in drug development

    DEFF Research Database (Denmark)

    Sarac, Sinan B; Rasmussen, Christian H; Rasmussen, Morten A.

    2012-01-01

    Major regulatory agencies, for example, FDA and EMA, have started to request comprehensive benefit-risk analyses of pharmaceutical products prior to approval or labelling expansion. The purpose of this study is to develop a generally applicable and reliable data-driven benefit-risk assessment......) discussion and formulation of an overall conclusion. To reduce the impact of subjective judgements, scores are assigned to each criterion on the basis of objective information (data) wherever possible. The proposed benefit-risk evaluation approach offers comprehensive, data-driven assessments that can...... method, where two or more drugs/doses can be compared. Our aim is to formulate an approach that is simple to apply, allows direct comparison of different types of risks and benefits, and is tailored for application in different disease areas both during clinical development and in the marketing approval...

  6. Assessment of dose to the expected overexposed radiation workers in Malaysia using dicentric technique from 2005 - 2006

    International Nuclear Information System (INIS)

    Noraisyah Mohd Yusof; Mohd Rodzi Ali; Noriah Jamal; Rehir Dahalan

    2008-08-01

    Malaysian Nuclear Agency is recognized by the Atomic Energy Licensing Board (AELB) as a National Biodosimetry Laboratory for performing the chromosome aberration tests in Malaysia. The test is to be done for radiation workers who received doses of more than the annual dose limit of 50 mSv or losses of film badge. This paper aims at presenting results of assessment of dose to the expected overexposed radiation workers in Malaysia using dicentric technique from year 2005 to 2006. Between that period of time, 20 blood samples (loss of film badge: 5 samples, overexposed: 13 samples and follow-up cases: 2 samples) were received from the AELB and the assessment of chromosome aberration were performed. The information on whole body exposure (WBE) was also received together with the samples for overexposed worker. We used the gold standard technique, which is the dicentric assay to analyze the blood samples. The technique is described in the IAEA Technical Report Series No. 405. The results were then analyzed and compared with the respective WBE for the overexposed worker. We found that no doses were observed for workers who loss their film badges and for follow-up cases. 30.8% of the overexposed workers show doses of more than 50 mSv. However, 69.2% shows doses lower than the annual limit. Variation of results may be due to delayed blood sampling from the workers. This technique is especially useful for immediate assessment of radiation exposure. (Author)

  7. ASSESSMENT OF UNCERTAINTY IN THE RADIATION DOSES FOR THE TECHA RIVER DOSIMETRY SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Napier, Bruce A.; Degteva, M. O.; Anspaugh, L. R.; Shagina, N. B.

    2009-10-23

    In order to provide more accurate and precise estimates of individual dose (and thus more precise estimates of radiation risk) for the members of the ETRC, a new dosimetric calculation system, the Techa River Dosimetry System-2009 (TRDS-2009) has been prepared. The deterministic version of the improved dosimetry system TRDS-2009D was basically completed in April 2009. Recent developments in evaluation of dose-response models in light of uncertain dose have highlighted the importance of different types of uncertainties in the development of individual dose estimates. These include uncertain parameters that may be either shared or unshared within the dosimetric cohort, and also the nature of the type of uncertainty as aleatory or epistemic and either classical or Berkson. This report identifies the nature of the various input parameters and calculational methods incorporated in the Techa River Dosimetry System (based on the TRDS-2009D implementation), with the intention of preparing a stochastic version to estimate the uncertainties in the dose estimates. This report reviews the equations, databases, and input parameters, and then identifies the author’s interpretations of their general nature. It presents the approach selected so that the stochastic, Monte-Carlo, implementation of the dosimetry System - TRDS-2009MC - will provide useful information regarding the uncertainties of the doses.

  8. EcoDoses. Improving radiological assessment of doses to man from terrestrial ecosystems. A status report for the NKS-B project 2004

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Sven P.; Isaksson, M.; Nilsson, Elisabeth (and others)

    2005-07-01

    The NKS B-programme EcoDoses project started in 2003 as a collaboration between all the Nordic countries. The aim of the project is to improve the radiological assessments of doses to man from terrestrial ecosystems. The present report sums up the work performed in the second phase of the project. The main topics in 2004 have been: (i) A continuation of previous work with a better approach for estimating global fallout on a regional or national scale, based on a correlation between precipitation and deposition rates. (ii) Fur-ther extension of the EcoDoses milk database. Estimation of effective ecological half lives of {sup 137}Cs in cows milk focussing on suitable post-Chernobyl time-series. Modelling integrated transfer of {sup 13}7{sup C}s to cow's milk from Nordic countries. (iii) Determination of effective ecological half lives for fresh water fish from Nordic lakes. (iv) Investigate ra-dioecological sensitivity for Nordic populations. (v) Food-chain modelling using the Eco-sys-model, which is the underlying food- and dose-module in several computerised deci-sion-making systems. (au)

  9. EcoDoses. Improving radiological assessment of doses to man from terrestrial ecosystems. A status report for the NKS-B project 2004

    International Nuclear Information System (INIS)

    Nielsen, Sven P.; Isaksson, M.; Nilsson, Elisabeth

    2005-07-01

    The NKS B-programme EcoDoses project started in 2003 as a collaboration between all the Nordic countries. The aim of the project is to improve the radiological assessments of doses to man from terrestrial ecosystems. The present report sums up the work performed in the second phase of the project. The main topics in 2004 have been: (i) A continuation of previous work with a better approach for estimating global fallout on a regional or national scale, based on a correlation between precipitation and deposition rates. (ii) Fur-ther extension of the EcoDoses milk database. Estimation of effective ecological half lives of 137 Cs in cows milk focussing on suitable post-Chernobyl time-series. Modelling integrated transfer of 13 7 C s to cow's milk from Nordic countries. (iii) Determination of effective ecological half lives for fresh water fish from Nordic lakes. (iv) Investigate ra-dioecological sensitivity for Nordic populations. (v) Food-chain modelling using the Eco-sys-model, which is the underlying food- and dose-module in several computerised deci-sion-making systems. (au)

  10. The development of BH3105E type neutron dose-equivalent meter

    International Nuclear Information System (INIS)

    Ji Changsong; Wang Tingting; Zhang Shuheng; Tan Baozeng

    2011-01-01

    A new BH3105E Type Neutron Dose-equivalent Meter has been developed. The 'multi-stick' ab- sorption method is used for thermal -14 MeV neutron equal dose-equivalent detection, what gives a high neutron sensitivity of 5 cps/μSv · h-1. RS-232 interface is accepted for signal communication (authors)

  11. Population dose assessment: characteristics of PC CREAM

    International Nuclear Information System (INIS)

    Alonso, Maria T.; Curti, Adriana R.

    2000-01-01

    This paper presents the main features of the PC CREAM, a program for performing radiological impact assessments due to radioactive discharges into the environment during the operation of radioactive and nuclear facilities. PC CREAM is a suite of six programs that can be used to estimate individual and collective radiation doses. The methodology of PC CREAM is based on updated environmental and dosimetric models, including ICRP 60 recommendations. The models include several exposure pathways and the input files are easy to access. The ergonomics of the program improves the user interaction and makes easier the input of local data. This program is useful for performing sensitivity analysis, siting studies and validation of model comparing the activity concentration output data with environmental monitoring data. The methodology of each module is described as well as the output data. (author)

  12. Development of a site specific environmental radiation assessment model for Youngkwang NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yang Geun; Song, Myung Jae; Shon, Soon Hwan; Shin, Sang Woon; Lee, Gap Bock; Yang, Kyung Hwa [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Kim, Seong Pyung; Kim, Jeong Kyu; Shin, Dae Yoon; Kim, Hyun Ku; Lee, Kyung Jin [Chosun University, Kwangju (Korea, Republic of)

    1996-12-31

    During the normal operation of nuclear power plants, a very small amount of radionuclide materials is released to the environment. The radionuclide releases to the environment may give rise to some additional radiation dose through a number of pathways. With a few exception, radionuclide transports are highly dependent on the environmental conditions such as topological features, atmospheric and oceanic conditions and socio-environmental characteristics, etc. The dose calculation in Korea are presently being performed using the models in US NRC Reg. Guide. However, these models which were originally released by the US NRC in 1977 are inadequate to deal with environmental movement of radionuclides in consideration of complex terrain, tidal condition of the Yellow Sea, and Youngkwang site specific conditions. KEPRI has developed the models to consider the site specific characteristics around Youngkwang NPPs, to give the realistic dose assessment, and to improve assurance and reliability in public dose calculation. (author). 41 figs., 70 refs.

  13. Development of a radiopharmaceutical dose calculator for pediatric patients undergoing diagnostic nuclear medicine studies

    International Nuclear Information System (INIS)

    Pandey, Anil Kumar; Sharma, Sanjay Kumar; Sharma, Punit; Gupta, Priyanka; Kumar, Rakesh

    2013-01-01

    It is important to ensure that as low as reasonably achievable (ALARA) concept during the radiopharmaceutical (RPH) dose administration in pediatric patients. Several methods have been suggested over the years for the calculation of individualized RPH dose, sometimes requiring complex calculations and large variability exists for administered dose in children. The aim of the present study was to develop a software application that can calculate and store RPH dose along with patient record. We reviewed the literature to select the dose formula and used Microsoft Access (a software package) to develop this application. We used the Microsoft Excel to verify the accurate execution of the dose formula. The manual and computer time using this program required for calculating the RPH dose were compared. The developed application calculates RPH dose for pediatric patients based on European Association of Nuclear Medicine dose card, weight based, body surface area based, Clark, Solomon Fried, Young and Webster's formula. It is password protected to prevent the accidental damage and stores the complete record of patients that can be exported to Excel sheet for further analysis. It reduces the burden of calculation and saves considerable time i.e., 2 min computer time as compared with 102 min (manual calculation with the calculator for all seven formulas for 25 patients). The software detailed above appears to be an easy and useful method for calculation of pediatric RPH dose in routine clinical practice. This software application will help in helping the user to routinely applied ALARA principle while pediatric dose administration. (author)

  14. A Web-Based System for Bayesian Benchmark Dose Estimation.

    Science.gov (United States)

    Shao, Kan; Shapiro, Andrew J

    2018-01-11

    Benchmark dose (BMD) modeling is an important step in human health risk assessment and is used as the default approach to identify the point of departure for risk assessment. A probabilistic framework for dose-response assessment has been proposed and advocated by various institutions and organizations; therefore, a reliable tool is needed to provide distributional estimates for BMD and other important quantities in dose-response assessment. We developed an online system for Bayesian BMD (BBMD) estimation and compared results from this software with U.S. Environmental Protection Agency's (EPA's) Benchmark Dose Software (BMDS). The system is built on a Bayesian framework featuring the application of Markov chain Monte Carlo (MCMC) sampling for model parameter estimation and BMD calculation, which makes the BBMD system fundamentally different from the currently prevailing BMD software packages. In addition to estimating the traditional BMDs for dichotomous and continuous data, the developed system is also capable of computing model-averaged BMD estimates. A total of 518 dichotomous and 108 continuous data sets extracted from the U.S. EPA's Integrated Risk Information System (IRIS) database (and similar databases) were used as testing data to compare the estimates from the BBMD and BMDS programs. The results suggest that the BBMD system may outperform the BMDS program in a number of aspects, including fewer failed BMD and BMDL calculations and estimates. The BBMD system is a useful alternative tool for estimating BMD with additional functionalities for BMD analysis based on most recent research. Most importantly, the BBMD has the potential to incorporate prior information to make dose-response modeling more reliable and can provide distributional estimates for important quantities in dose-response assessment, which greatly facilitates the current trend for probabilistic risk assessment. https://doi.org/10.1289/EHP1289.

  15. Assessment of Regional Pediatric Computed Tomography Dose Indices in Tamil Nadu.

    Science.gov (United States)

    Saravanakumar, A; Vaideki, K; Govindarajan, K N; Jayakumar, S; Devanand, B

    2017-01-01

    The aim of this article is to assess Tamil Nadu pediatric computed tomography (CT) diagnostic reference levels (DRLs) by collecting radiation dose data for the most commonly performed CT examinations. This work was performed for thirty CT scanners installed in various parts of the Tamil Nadu region. The patient cohort was divided into two age groups: <1 year, and 1-5 years. CT dose indices were measured using a 10 cm 3 pencil ion chamber with pediatric head and body polymethyl methacrylate phantoms. Dose data such as volumetric CT dose index (CTDI v ) and dose length product (DLP) on a minimum of twenty average-sized pediatric patients in each category were recorded to calculate a mean site CTDI v and DLP value. The rounded 75 th percentile was used to calculate a pediatric DRL for each hospital, and then region by compiling all results. Data were collected for 3600 pediatric patients. Pediatric CT DRL for two age groups: <1 year (CTDI v and DLP of head [20 mGy, 352 mGy.cm], chest [7 mGy, 120 mGy.cm] and abdomen [12 mGy, 252 mGy.cm]), and 1-5 years (CTDI v and DLP of head [38 mGy, 505 mGy.cm], chest [8 mGy, 132 mGy.cm] and abdomen [14 mGy, 270 mGy.cm]) for select procedures have been calculated. Proposed pediatric DRLs of CTDI v and DLP for head procedure were lower, and for chest and abdomen procedures were higher than European pediatric DRLs for both age groups.

  16. Issues in weighting bioassay data for use in regressions for internal dose assessments

    International Nuclear Information System (INIS)

    Strom, D.J.

    1992-11-01

    For use of bioassay data in internal dose assessment, research should be done to clarify the goal desired, the choice of method to achieve the goal, the selection of adjustable parameters, and on the ensemble of information that is available. Understanding of these issues should determine choices of weighting factors for bioassay data used in regression models. This paper provides an assessment of the relative importance of the various factors

  17. Radioactivity measurements in the vicinity of the mine waste heap at Crossen and radiation dose assessment

    International Nuclear Information System (INIS)

    Kulzer, R.

    1998-01-01

    The radiation dose to the population living in the vicinity of the mine waste heap is assessed. The measurements carried out were to verify the dose relevance of ambient radioactivity on site, in particular the ingestion and inhalation pathways and the external exposure pathways. The nuclide Pb-210 was used as an indicator because of its large dose factor for assessment of ingestion and its airborne dispersion as an Rn-222 daughter product. The waste heap material releases large quantities of this nuclide. Ingestion of radioactivity from the waste heap may be caused by wind-borne erosion and activity deposition on plants in the area. Therefore, the specific activities of Pb-210 and Ra-226 have been measured in soil and plant specimens sampled at various distances from the waste heap. (orig./CB) [de

  18. Dose and risk assessment for intrusion into mixed waste disposal sites

    International Nuclear Information System (INIS)

    Kennedy, W.E. Jr.; Aaberg, R.L.

    1991-10-01

    Sites previously used for disposal of radioactive and hazardous chemical materials have resulted in situations that pose a potential threat to humans from inadvertent intrusion. An example generic scenario analysis was developed to demonstrate the evaluation of potential exposure to either cleanup workers or members of the public who intrude into buried waste containing both radioactive and hazardous chemical contaminants. The example scenarios consist of a collection of exposure routes (or pathways) with specific modeling assumptions for well-drilling and for excavation to construct buildings. These scenarios are used to describe conceptually some potential patterns of activity by non-protected human beings during intrusion into mixed-waste disposal sites. The dose from exposure to radioactive materials is calculated using the GENII software system and converted to risk by using factors from ICRP Publication 60. The hazard assessment for nonradioactive materials is performed using recent guidelines from the US Environmental Protection Agency (EPA). The example results are in the form of cancer risk for carcinogens and radiation exposure

  19. Development of dose rate estimation system for FBR maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Iizawa, Katsuyuki [Japan Nuclear Cycle Development Inst., Tsuruga Head Office, International Cooperation and Technology Development Center, Tsuruga, Fukui (Japan); Takeuchi, Jun; Yoshikawa, Satoru [Hitachi Engineering Company, Ltd., Hitachi, Ibaraki (Japan); Urushihara, Hiroshi [Ibaraki Hitachi Information Service Co., Ltd., Omika, Ibaraki (Japan)

    2001-09-01

    During maintenance activities on the primary sodium cooling system by an FBR Personnel radiation exposure arises mainly from the presence of radioactive corrosion products (CP). A CP behavior analysis code, PSYCHE, and a radiation shielding calculation code, QAD-CG, have been developed and applied to investigate the possible reduction of radiation exposure of workers. In order to make these evaluation methods more accessible to plant engineers, the user interface of the codes has been improved and an integrated system, including visualization of the calculated gamma-ray radiation dose-rate map, has been developed. The system has been verified by evaluating the distribution of the radiation dose-rate within the Monju primary heat transport system cells from the estimated saturated CP deposition and distribution which would be present following about 20 cycles of full power operation. (author)

  20. Development of dose rate estimation system for FBR maintenance

    International Nuclear Information System (INIS)

    Iizawa, Katsuyuki; Takeuchi, Jun; Yoshikawa, Satoru; Urushihara, Hiroshi

    2001-01-01

    During maintenance activities on the primary sodium cooling system by an FBR Personnel radiation exposure arises mainly from the presence of radioactive corrosion products (CP). A CP behavior analysis code, PSYCHE, and a radiation shielding calculation code, QAD-CG, have been developed and applied to investigate the possible reduction of radiation exposure of workers. In order to make these evaluation methods more accessible to plant engineers, the user interface of the codes has been improved and an integrated system, including visualization of the calculated gamma-ray radiation dose-rate map, has been developed. The system has been verified by evaluating the distribution of the radiation dose-rate within the Monju primary heat transport system cells from the estimated saturated CP deposition and distribution which would be present following about 20 cycles of full power operation. (author)

  1. Committed dose assessment based on background outdoor gamma exposure in Chihuahua City, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Luevano G, S.; Perez T, A.; Pinedo A, C.; Renteria V, M. [Universidad Autonoma de Chihuahua, Facultad de Zootecnia y Ecologia, Perif. Francisco R. Almada Km 1, 31415 Chihuahua, Chih. (Mexico); Carrillo F, J.; Montero C, M. E., E-mail: mrenteria@uach.mx [Centro de Investigacion en Materiales Avanzados, Miguel de Cervantes 120, 31136 Chihuahua, Chih. (Mexico)

    2015-10-15

    Full text: Determining ionizing radiation in a geographic area serves to assess its effects on populations health. The aim of this study was to evaluate the spatial distribution of the background environmental outdoor gamma dose rates in Chihuahua City. This study also estimated the committed dose and the lifetime cancer risks of the population of this city. To determine the outdoor gamma dose rate in air, annual effective dose, and the lifetime cancer risk, 48 sampling points were randomly selected along the Chihuahua City. Outdoor gamma dose rate measurements were carried out by using a Geiger-Muller counter. At the same sites, 48 soil samples were taken to obtain the activity concentrations of {sup 226}Ra, {sup 232}Th, {sup 40}K and their terrestrial gamma dose rates. Radioisotope activity concentrations were determined by gamma spectrometry. Outdoor gamma dose rates ranged from 56 to 193 n Gy h{sup -1}. Results indicated that lifetime effective dose to inhabitants of Chihuahua City is in average of 19.8 mSv, resulting in a lifetime cancer risk of 0.001. In addition, the mean of activity concentrations in soil were 51.8, 73.1, and 1096.5 Bq kg{sup -1}, of {sup 226}Ra, {sup 232}Th and {sup 40}K, respectively. From the analysis of the spatial distribution of {sup 232}Th, {sup 226}Ra, and {sup 40}K is to north, to north-center, and to south of city, respectively. In conclusion, natural background gamma dose received by inhabitants of Chihuahua City is high and mainly due to geological characteristics of the zone. (Author)

  2. Internal dose assessment of 238U contaminated soils based on in-vitro gastrointestinal protocol

    Science.gov (United States)

    Perama, Yasmin Mohd Idris; Rashid, Nur Shahidah Abdul; Majid, Amran Ab.; Siong, Khoo Kok

    2017-01-01

    Human exposure to natural radioactive uranium has been a great interest as more industrial rapidly growing contributes to radiation risks. The aim of this case study was to determine the internal dose in humans incorporated with ingestion of 238U contaminated soils. A gastrointestinal analogue test was employed to simulate the human digestive tract. In-vitro approach via German DIN 19738 model was developed in order to estimate the internal exposure of 238U due to ingestion of different types of soils. Synthetic gastrointestinal fluids assay via in-vitro method were produced to determine the concentration of 238U in various soils using ICP-MS. Based on the results, concentration of 238U in BRIS, laterite, peat and alluvium soils were in ranged between (0.0061 ± 0.0057 - 0.0488 ± 0.0148) ppm and (0.0005 ± 0.0004 - 0.0046 ± 0.0007) ppm in gastric and gastrointestinal phase respectively. Types of soil compositions and pH medium were some of the factors that influence mobilization and solubility of 238U contaminanted soil into the digestive juices that resembles human gastrointestinal tract. For the purpose of internal dose assessment, the committed efective dose from 238U intake in soils ranged between 1.237 × 10-11 - 9.8993 × 10-11 Sv y-1 for gastric phase and 1.0184 × 10-12 - 9.3294 × 10-12 Sv y-1 for gastric-intestinal phase. The internal dose measurements from this study were much lower from the recommended values. Hence, ingestion of 238U contaminated soils would not be expected to pose major health risk to humans.

  3. Doses from radiation exposure

    International Nuclear Information System (INIS)

    Menzel, H-G.; Harrison, J.D.

    2012-01-01

    Practical implementation of the International Commission on Radiological Protection’s (ICRP) system of protection requires the availability of appropriate methods and data. The work of Committee 2 is concerned with the development of reference data and methods for the assessment of internal and external radiation exposure of workers and members of the public. This involves the development of reference biokinetic and dosimetric models, reference anatomical models of the human body, and reference anatomical and physiological data. Following ICRP’s 2007 Recommendations, Committee 2 has focused on the provision of new reference dose coefficients for external and internal exposure. As well as specifying changes to the radiation and tissue weighting factors used in the calculation of protection quantities, the 2007 Recommendations introduced the use of reference anatomical phantoms based on medical imaging data, requiring explicit sex averaging of male and female organ-equivalent doses in the calculation of effective dose. In preparation for the calculation of new dose coefficients, Committee 2 and its task groups have provided updated nuclear decay data (ICRP Publication 107) and adult reference computational phantoms (ICRP Publication 110). New dose coefficients for external exposures of workers are complete (ICRP Publication 116), and work is in progress on a series of reports on internal dose coefficients to workers from inhaled and ingested radionuclides. Reference phantoms for children will also be provided and used in the calculation of dose coefficients for public exposures. Committee 2 also has task groups on exposures to radiation in space and on the use of effective dose.

  4. SU-F-J-194: Development of Dose-Based Image Guided Proton Therapy Workflow

    Energy Technology Data Exchange (ETDEWEB)

    Pham, R; Sun, B; Zhao, T; Li, H; Yang, D; Grantham, K; Goddu, S; Santanam, L; Bradley, J; Mutic, S; Kandlakunta, P; Zhang, T [Washington University School of Medicine, Saint Louis, MO (United States)

    2016-06-15

    Purpose: To implement image-guided proton therapy (IGPT) based on daily proton dose distribution. Methods: Unlike x-ray therapy, simple alignment based on anatomy cannot ensure proper dose coverage in proton therapy. Anatomy changes along the beam path may lead to underdosing the target, or overdosing the organ-at-risk (OAR). With an in-room mobile computed tomography (CT) system, we are developing a dose-based IGPT software tool that allows patient positioning and treatment adaption based on daily dose distributions. During an IGPT treatment, daily CT images are acquired in treatment position. After initial positioning based on rigid image registration, proton dose distribution is calculated on daily CT images. The target and OARs are automatically delineated via deformable image registration. Dose distributions are evaluated to decide if repositioning or plan adaptation is necessary in order to achieve proper coverage of the target and sparing of OARs. Besides online dose-based image guidance, the software tool can also map daily treatment doses to the treatment planning CT images for offline adaptive treatment. Results: An in-room helical CT system is commissioned for IGPT purposes. It produces accurate CT numbers that allow proton dose calculation. GPU-based deformable image registration algorithms are developed and evaluated for automatic ROI-delineation and dose mapping. The online and offline IGPT functionalities are evaluated with daily CT images of the proton patients. Conclusion: The online and offline IGPT software tool may improve the safety and quality of proton treatment by allowing dose-based IGPT and adaptive proton treatments. Research is partially supported by Mevion Medical Systems.

  5. Dose, image quality and spine modeling assessment of biplanar EOS micro-dose radiographs for the follow-up of in-brace adolescent idiopathic scoliosis patients.

    Science.gov (United States)

    Morel, Baptiste; Moueddeb, Sonia; Blondiaux, Eleonore; Richard, Stephen; Bachy, Manon; Vialle, Raphael; Ducou Le Pointe, Hubert

    2018-05-01

    The aim of this study was to compare the radiation dose, image quality and 3D spine parameter measurements of EOS low-dose and micro-dose protocols for in-brace adolescent idiopathic scoliosis (AIS) patients. We prospectively included 25 consecutive patients (20 females, 5 males) followed for AIS and undergoing brace treatment. The mean age was 12 years (SD 2 years, range 8-15 years). For each patient, in-brace biplanar EOS radiographs were acquired in a standing position using both the conventional low-dose and micro-dose protocols. Dose area product (DAP) was systematically recorded. Diagnostic image quality was qualitatively assessed by two radiologists for visibility of anatomical structures. The reliability of 3D spine modeling between two operators was quantitatively evaluated for the most clinically relevant 3D radiological parameters using intraclass correlation coefficient (ICC). The mean DAP for the posteroanterior and lateral acquisitions was 300 ± 134 and 433 ± 181 mGy cm 2 for the low-dose radiographs, and 41 ± 19 and 81 ± 39 mGy cm 2 for micro-dose radiographs. Image quality was lower with the micro-dose protocol. The agreement was "good" to "very good" for all measured clinical parameters when comparing the low-dose and micro-dose protocols (ICC > 0.73). The micro-dose protocol substantially reduced the delivered dose (by a factor of 5-7 compared to the low-dose protocol) in braced children with AIS. Although image quality was reduced, the micro-dose protocol proved to be adapted to radiological follow-up, with adequate image quality and reliable clinical measurements. These slides can be retrieved under Electronic Supplementary Material.

  6. Calculation of dose conversion factors for doses in the fingernails to organ doses at external gamma irradiation in air

    International Nuclear Information System (INIS)

    Khailov, A.M.; Ivannikov, A.I.; Skvortsov, V.G.; Stepanenko, V.F.; Orlenko, S.P.; Flood, A.B.; Williams, B.B.; Swartz, H.M.

    2015-01-01

    Absorbed doses to fingernails and organs were calculated for a set of homogenous external gamma-ray irradiation geometries in air. The doses were obtained by stochastic modeling of the ionizing particle transport (Monte Carlo method) for a mathematical human phantom with arms and hands placed loosely along the sides of the body. The resulting dose conversion factors for absorbed doses in fingernails can be used to assess the dose distribution and magnitude in practical dose reconstruction problems. For purposes of estimating dose in a large population exposed to radiation in order to triage people for treatment of acute radiation syndrome, the calculated data for a range of energies having a width of from 0.05 to 3.5 MeV were used to convert absorbed doses in fingernails to corresponding doses in organs and the whole body as well as the effective dose. Doses were assessed based on assumed rates of radioactive fallout at different time periods following a nuclear explosion. - Highlights: • Elemental composition and density of nails were determined. • MIRD-type mathematical human phantom with arms and hands was created. • Organ doses and doses to nails were calculated for external photon exposure in air. • Effective dose and nail doses values are close for rotational and soil surface exposures.

  7. Mechanism-based risk assessment strategy for drug-induced cholestasis using the transcriptional benchmark dose derived by toxicogenomics.

    Science.gov (United States)

    Kawamoto, Taisuke; Ito, Yuichi; Morita, Osamu; Honda, Hiroshi

    2017-01-01

    Cholestasis is one of the major causes of drug-induced liver injury (DILI), which can result in withdrawal of approved drugs from the market. Early identification of cholestatic drugs is difficult due to the complex mechanisms involved. In order to develop a strategy for mechanism-based risk assessment of cholestatic drugs, we analyzed gene expression data obtained from the livers of rats that had been orally administered with 12 known cholestatic compounds repeatedly for 28 days at three dose levels. Qualitative analyses were performed using two statistical approaches (hierarchical clustering and principle component analysis), in addition to pathway analysis. The transcriptional benchmark dose (tBMD) and tBMD 95% lower limit (tBMDL) were used for quantitative analyses, which revealed three compound sub-groups that produced different types of differential gene expression; these groups of genes were mainly involved in inflammation, cholesterol biosynthesis, and oxidative stress. Furthermore, the tBMDL values for each test compound were in good agreement with the relevant no observed adverse effect level. These results indicate that our novel strategy for drug safety evaluation using mechanism-based classification and tBMDL would facilitate the application of toxicogenomics for risk assessment of cholestatic DILI.

  8. SU-F-I-38: Patient Organ Specific Dose Assessment in Coronary CT Angiograph Using Voxellaized Volume Dose Index in Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Fallal, Mohammadi Gh.; Riyahi, Alam N.; Graily, Gh. [Tehran University of Medical Scienced(TUMS), School of Medicine, Department of Nedical Physics and Biomedical Engineering, Tehran (Iran, Islamic Republic of); Paydar, R. [Iran University of Medical Sciences(IUMS), Allied Medicine Faculty, Department of radiation Sciences, Tehran (Iran, Islamic Republic of)

    2016-06-15

    Purpose: Clinical use of multi detector computed tomography(MDCT) in diagnosis of diseases due to high speed in data acquisition and high spatial resolution is significantly increased. Regarding to the high radiation dose in CT and necessity of patient specific radiation risk assessment, the adoption of new method in the calculation of organ dose is completely required and necessary. In this study by introducing a conversion factor, patient organ dose in thorax region based on CT image data using MC system was calculated. Methods: The geometry of x-ray tube, inherent filter, bow tie filter and collimator were designed using EGSnrc/BEAMnrc MC-system component modules according to GE-Light-speed 64-slices CT-scanner geometry. CT-scan image of patient thorax as a specific phantom was voxellised with 6.25mm3 in voxel and 64×64×20 matrix size. Dose to thorax organ include esophagus, lung, heart, breast, ribs, muscle, spine, spinal cord with imaging technical condition of prospectively-gated-coronary CT-Angiography(PGT) as a step and shoot method, were calculated. Irradiation of patient specific phantom was performed using a dedicated MC-code as DOSXYZnrc with PGT-irradiation model. The ratio of organ dose value calculated in MC-method to the volume CT dose index(CTDIvol) reported by CT-scanner machine according to PGT radiation technique has been introduced as conversion factor. Results: In PGT method, CTDIvol was 10.6mGy and Organ Dose/CTDIvol conversion factor for esophagus, lung, heart, breast, ribs, muscle, spine and spinal cord were obtained as; 0.96, 1.46, 1.2, 3.28. 6.68. 1.35, 3.41 and 0.93 respectively. Conclusion: The results showed while, underestimation of patient dose was found in dose calculation based on CTDIvol, also dose to breast is higher than the other studies. Therefore, the method in this study can be used to provide the actual patient organ dose in CT imaging based on CTDIvol in order to calculation of real effective dose(ED) based on organ dose

  9. Development of transmission dose estimation algorithm for in vivo dosimetry in high energy radiation treatment

    International Nuclear Information System (INIS)

    Yun, Hyong Geun; Shin, Kyo Chul; Hun, Soon Nyung; Woo, Hong Gyun; Ha, Sung Whan; Lee, Hyoung Koo

    2004-01-01

    In vivo dosimetry is very important for quality assurance purpose in high energy radiation treatment. Measurement of transmission dose is a new method of in vivo dosimetry which is noninvasive and easy for daily performance. This study is to develop a tumor dose estimation algorithm using measured transmission dose for open radiation field. For basic beam data, transmission dose was measured with various field size (FS) of square radiation field, phantom thickness (Tp), and phantom chamber distance (PCD) with a acrylic phantom for 6 MV and 10 MV X-ray. Source to chamber distance (SCD) was set to 150 cm. Measurement was conducted with a 0.6 cc Farmer type ion chamber. By using regression analysis of measured basic beam data, a transmission dose estimation algorithm was developed. Accuracy of the algorithm was tested with flat solid phantom with various thickness in various settings of rectangular fields and various PCD. In our developed algorithm, transmission dose was equated to quadratic function of log(A/P) (where A/P is area-perimeter ratio) and the coefficients of the quadratic functions were equated to tertiary functions of PCD. Our developed algorithm could estimate the radiation dose with the errors within ±0.5% for open square field, and with the errors within ±1.0% for open elongated radiation field. Developed algorithm could accurately estimate the transmission dose in open radiation fields with various treatment settings of high energy radiation treatment. (author)

  10. [Efficacy of low-dose tadalafil on ED assessed by Self-Esteem and Relationship Questionnaire].

    Science.gov (United States)

    Li, Jing-Ping; Li, Fei; Guo, Wen-Bin; Zhou, Qi-Zhao; Liu, Cun-Dong; Mao, Xiang-Ming; Tan, Wan-Long; Zheng, Shao-Bin

    2010-12-01

    To explore the effects of low-dose oral tadalafil on self-esteem, confidence and sexual relationship in ED patients. We treated 17 ED patients with oral tadalafil at the low dose of 5 mg once daily for 12 weeks, and used the paired t test to compare their scores on The Self-Esteem and Relationship Questionnaire (SEAR) and IIEF-5 and the results of nocturnal penile tumescence (NPT) obtained by nocturnal electrobioimpedance volumetric assessment (NEVA) before and after the medication. The scores on SEAR and IIEF-5 were significantly increased (P P Low-dose oral tadalafil once daily can significantly improve the self-esteem, confidence, sexual relationship satisfaction and NPT of ED patients.

  11. SU-F-T-119: Development of Heart Prediction Model to Increase Accuracy of Dose Reconstruction for Radiotherapy Patients

    International Nuclear Information System (INIS)

    Mosher, E; Choi, M; Lee, C; Jones, E

    2016-01-01

    Purpose: To assess individual variation in heart volume and location in order to develop a prediction model of the heart. This heart prediction model will be used to calculate individualized heart doses for radiotherapy patients in epidemiological studies. Methods: Chest CT images for 30 adult male and 30 adult female patients were obtained from NIH Clinical Center. Image-analysis computer programs were used to segment the whole heart and 8 sub-regions and to measure the volume of each sub- region and the dimension of the whole heart. An analytical dosimetry method was used for the 30 adult female patients to estimate mean heart dose during conventional left breast radiotherapy. Results: The average volumes of the whole heart were 803.37 cm"3 (COV 18.8%) and 570.19 cm"3 (COV 18.8%) for adult male and female patients, respectively, which are comparable with the international reference volumes of 807.69 cm"3 for males and 596.15 cm"3 for females. Some patient characteristics were strongly correlated (R"2>0.5) with heart volume and heart dimensions (e.g., Body Mass Index vs. heart depth in males: R"2=0.54; weight vs. heart width in the adult females: R"2=0.63). We found that the mean heart dose 3.805 Gy (assuming prescribed dose of 50 Gy) in the breast radiotherapy simulations of the 30 adult females could be an underestimate (up to 1.6-fold) or overestimate (up to 1.8-fold) of the patient-specific heart dose. Conclusion: The study showed the significant variation in patient heart volumes and dimensions, resulting in substantial dose errors when a single average heart model is used for retrospective dose reconstruction. We are completing a multivariate analysis to develop a prediction model of the heart. This model will increase accuracy in dose reconstruction for radiotherapy patients and allow us to individualize heart dose calculations for patients whose CT images are not available.

  12. SU-F-T-119: Development of Heart Prediction Model to Increase Accuracy of Dose Reconstruction for Radiotherapy Patients

    Energy Technology Data Exchange (ETDEWEB)

    Mosher, E; Choi, M; Lee, C [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD (United States); Jones, E [Radiology and Imaging Sciences Clinical Center, National Institutes of Health, Bethesda, MD (United States)

    2016-06-15

    Purpose: To assess individual variation in heart volume and location in order to develop a prediction model of the heart. This heart prediction model will be used to calculate individualized heart doses for radiotherapy patients in epidemiological studies. Methods: Chest CT images for 30 adult male and 30 adult female patients were obtained from NIH Clinical Center. Image-analysis computer programs were used to segment the whole heart and 8 sub-regions and to measure the volume of each sub- region and the dimension of the whole heart. An analytical dosimetry method was used for the 30 adult female patients to estimate mean heart dose during conventional left breast radiotherapy. Results: The average volumes of the whole heart were 803.37 cm{sup 3} (COV 18.8%) and 570.19 cm{sup 3} (COV 18.8%) for adult male and female patients, respectively, which are comparable with the international reference volumes of 807.69 cm{sup 3} for males and 596.15 cm{sup 3} for females. Some patient characteristics were strongly correlated (R{sup 2}>0.5) with heart volume and heart dimensions (e.g., Body Mass Index vs. heart depth in males: R{sup 2}=0.54; weight vs. heart width in the adult females: R{sup 2}=0.63). We found that the mean heart dose 3.805 Gy (assuming prescribed dose of 50 Gy) in the breast radiotherapy simulations of the 30 adult females could be an underestimate (up to 1.6-fold) or overestimate (up to 1.8-fold) of the patient-specific heart dose. Conclusion: The study showed the significant variation in patient heart volumes and dimensions, resulting in substantial dose errors when a single average heart model is used for retrospective dose reconstruction. We are completing a multivariate analysis to develop a prediction model of the heart. This model will increase accuracy in dose reconstruction for radiotherapy patients and allow us to individualize heart dose calculations for patients whose CT images are not available.

  13. Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images.

    Science.gov (United States)

    Favazza, Christopher P; Ferrero, Andrea; Yu, Lifeng; Leng, Shuai; McMillan, Kyle L; McCollough, Cynthia H

    2017-07-01

    The use of iterative reconstruction (IR) algorithms in CT generally decreases image noise and enables dose reduction. However, the amount of dose reduction possible using IR without sacrificing diagnostic performance is difficult to assess with conventional image quality metrics. Through this investigation, achievable dose reduction using a commercially available IR algorithm without loss of low contrast spatial resolution was determined with a channelized Hotelling observer (CHO) model and used to optimize a clinical abdomen/pelvis exam protocol. A phantom containing 21 low contrast disks-three different contrast levels and seven different diameters-was imaged at different dose levels. Images were created with filtered backprojection (FBP) and IR. The CHO was tasked with detecting the low contrast disks. CHO performance indicated dose could be reduced by 22% to 25% without compromising low contrast detectability (as compared to full-dose FBP images) whereas 50% or more dose reduction significantly reduced detection performance. Importantly, default settings for the scanner and protocol investigated reduced dose by upward of 75%. Subsequently, CHO-based protocol changes to the default protocol yielded images of higher quality and doses more consistent with values from a larger, dose-optimized scanner fleet. CHO assessment provided objective data to successfully optimize a clinical CT acquisition protocol.

  14. Development of a Quantitative Framework for Regulatory Risk Assessments: Probabilistic Approaches

    International Nuclear Information System (INIS)

    Wilmot, R.D.

    2003-11-01

    The Swedish regulators have been active in the field of performance assessment for many years and have developed sophisticated approaches to the development of scenarios and other aspects of assessments. These assessments have generally used dose as the assessment end-point and have been based on deterministic calculations. Recently introduced Swedish regulations have introduced a risk criterion for radioactive waste disposal: the annual risk of harmful effects after closure of a disposal facility should not exceed 10 -6 for a representative individual in the group exposed to the greatest risk. A recent review of the overall structure of risk assessments in safety cases concluded that there are a number of decisions and assumptions in the development of a risk assessment methodology that could potentially affect the calculated results. Regulatory understanding of these issues, potentially supported by independent calculations, is important in preparing for review of a proponent's risk assessment. One approach to evaluating risk in performance assessments is to use the concept of probability to express uncertainties, and to propagate these probabilities through the analysis. This report describes the various approaches available for undertaking such probabilistic analyses, both as a means of accounting for uncertainty in the determination of risk and more generally as a means of sensitivity and uncertainty analysis. The report discusses the overall nature of probabilistic analyses and how they are applied to both the calculation of risk and sensitivity analyses. Several approaches are available, including differential analysis, response surface methods and simulation. Simulation is the approach most commonly used, both in assessments for radioactive waste disposal and in other subject areas, and the report describes the key stages of this approach in detail. Decisions relating to the development of input PDFs, sampling methods (including approaches to the treatment

  15. Development of new methodology for dose calculation in photographic dosimetry

    International Nuclear Information System (INIS)

    Daltro, T.F.L.

    1994-01-01

    A new methodology for equivalent dose calculations has been developed at IPEN-CNEN/SP to be applied at the Photographic Dosimetry Laboratory using artificial intelligence techniques by means of neutral network. The research was orientated towards the optimization of the whole set of parameters involves in the film processing going from the irradiation in order to obtain the calibration curve up to the optical density readings. The learning of the neutral network was performed by taking the readings of optical density from calibration curve as input and the effective energy and equivalent dose as output. The obtained results in the intercomparison show an excellent agreement with the actual values of dose and energy given by the National Metrology Laboratory of Ionizing Radiation. (author)

  16. Development of new methodology for dose calculation in photographic dosimetry

    International Nuclear Information System (INIS)

    Daltro, T.F.L.; Campos, L.L.

    1994-01-01

    A new methodology for equivalent dose calculation has been developed at IPEN-CNEN/SP to be applied at the Photographic Dosimetry Laboratory using artificial intelligence techniques by means of neural network. The research was oriented towards the optimization of the whole set of parameters involved in the film processing going from the irradiation in order to obtain the calibration curve up to the optical density readings. The learning of the neural network was performed by taking readings of optical density from calibration curve as input and the effective energy and equivalent dose as output. The obtained results in the intercomparison show an excellent agreement with the actual values of dose and energy given by the National Metrology Laboratory of Ionizing Radiation

  17. Dose delivery study for a novel compact proton accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kraus, Kim Melanie

    2014-01-15

    Proton therapy has played an important role in the treatment of cancer with radiation therapy for more than 60 years. Active spot scanning to deliver highly conformal dose to the tumor has been developed. However, the availability of proton therapy to the patients is still limited, partly, due to the high costs and sizes of large proton therapy centers. Therefore, a novel compact proton single room facility based on a linear accelerator mounted on a gantry has been proposed, named TULIP (TUrning LInac for Proton therapy). This accelerator allows for active energy variation on a milliseconds time scale. This work aims to assess the possibilities of dose delivery with TULIP to exploit its beneficial features with respect to dose delivery. We developed a software tool, simulating the dose delivery to the tumor. By means of this software tool, we assessed different delivery methods and found 3D spot scanning to be superior to rotational dose delivery with regard to dose and irradiation time. In a second part, we expanded the investigations to dose delivery to moving targets. Due to fast energy variation, we found TULIP to be preferably suitable for rescanning, confirmed by irradiation times of only a few minutes.

  18. Dose delivery study for a novel compact proton accelerator

    International Nuclear Information System (INIS)

    Kraus, Kim Melanie

    2014-01-01

    Proton therapy has played an important role in the treatment of cancer with radiation therapy for more than 60 years. Active spot scanning to deliver highly conformal dose to the tumor has been developed. However, the availability of proton therapy to the patients is still limited, partly, due to the high costs and sizes of large proton therapy centers. Therefore, a novel compact proton single room facility based on a linear accelerator mounted on a gantry has been proposed, named TULIP (TUrning LInac for Proton therapy). This accelerator allows for active energy variation on a milliseconds time scale. This work aims to assess the possibilities of dose delivery with TULIP to exploit its beneficial features with respect to dose delivery. We developed a software tool, simulating the dose delivery to the tumor. By means of this software tool, we assessed different delivery methods and found 3D spot scanning to be superior to rotational dose delivery with regard to dose and irradiation time. In a second part, we expanded the investigations to dose delivery to moving targets. Due to fast energy variation, we found TULIP to be preferably suitable for rescanning, confirmed by irradiation times of only a few minutes.

  19. Development of methodology for assessment of absorbed dose and stopping power for low energy conversion electrons; Desenvolvimento de uma metodologia para estimativa da dose absorvida e do poder de freamento para eletrons de conversao de baixa energia

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Ivan Pedro Salati de

    1995-08-01

    The evaluation of absorbed dose in the case of external and internalcontamination due to radionuclides is sometimes hard, because of the difficulties in the assessment of the absorbed dose caused by electrons with energy less than 100 KeV in mucous membrane. In this work, a methodology for assessment of absorbed dose and stopping power in VYNS (co-polymer of polivinyl chloride - acetate) absorbers, for the 62.5 KeV and 84-88 KeV energy {sup 109} Cd conversion electrons, working with a 4 {pi} proportional pressurized detector, is presented. In order to assure the reproducibility of measurement conditions, one of the detector halves has been used to obtain a spectrum of a thin {sup 109} Cd source, without absorber. The other half of the detector was used in concomitance to obtain spectra with different thicknesses if absorber. The absorbed energy was obtained subtracting each spectrum with absorber from the spectrum without absorber, which were stored in a microcomputer connected to signal processing systems by ACE type interface. The VYNS weight and thickness were evaluated using common radionuclide metrology procedures. As VYNS has characteristics similar to a tissue equivalent material, the results obtained are consistent with dosimetric concepts and have a good agreement with those of the literature. (author)

  20. Assessment of volumetric-modulated arc therapy for constant and variable dose rates

    Directory of Open Access Journals (Sweden)

    Mariluz De Ornelas-Couto

    2017-01-01

    Full Text Available Purpose: The aim of this study is to compare the effects of dose rate on volumetric-modulated arc therapy plans to determine optimal dose rates for prostate and head and neck (HN cases. Materials and Methods: Ten prostate and ten HN cases were retrospectively studied. For each case, seven plans were generated: one variable dose rate (VDR and six constant dose rate (CDR (100–600 monitor units [MUs]/min plans. Prescription doses were: 80 Gy to planning target volume (PTV for the prostate cases, and 70, 60, and 54 Gy to PTV1, PTV2, and PTV3, respectively, for HN cases. Plans were normalized to 95% of the PTV and PTV1, respectively, with the prescription dose. Plans were assessed using Dose-Volume-Histogram metrics, homogeneity index, conformity index, MUs, and delivery time. Results: For the prostate cases, significant differences were found for rectum D35 between VDR and all CDR plans, except CDR500. Furthermore, VDR was significantly different than CDR100 and 200 for bladder D50. Delivery time for all CDR plans and MUs for CDR400–600 were significantly higher when compared to VDR. HN cases showed significant differences between VDR and CDR100, 500 and 600 for D2 to the cord and brainstem. Significant differences were found for delivery time and MUs for all CDR plans, except CDR100 for number of MUs. Conclusion: The most significant differences were observed in delivery time and number of MUs. All-in-all, the best CDR for prostate cases was found to be 300 MUs/min and 200 or 300 MUs/min for HN cases. However, VDR plans are still the choice in terms of MU efficiency and plan quality.