WorldWideScience

Sample records for doppler ultrasonography evidence

  1. Effect of glucocorticosteroid injections in tennis elbow verified on colour Doppler ultrasonography: evidence of inflammation

    DEFF Research Database (Denmark)

    Torp-Pedersen, T.E.; Torp-Pedersen, S.T.; Qvistgaard, E.

    2008-01-01

    were evaluated at baseline before the injection and at 2 weeks of follow-up. Outcome measures were changes in pain score and US parameters (resistive index (RI) and the amount of colour within the CEO). Prognosticators for outcome were: use of computer mouse, symptom duration, elbow strain, RI, colour...... fraction, Likert pain score, pain at rest, pain during activity, age, height, weight, disease in dominant versus nondominant arm. RESULTS: All but one patient experienced improvement of general elbow pain perception at follow-up at 2 weeks. In parallel, Doppler US showed significant reduction in colour...

  2. Diabetic Nephropathy : Evaluation with Doppler Ultrasonography

    International Nuclear Information System (INIS)

    Sim, Jung Suk; Kim, Seung Hyup; Kang, Heung Sik; Park, Jae Hyung; Han, Man Chung

    1996-01-01

    To compare Doppler ultrasonography with laboratory tests in evaluation of diabetic nephropathy. Fifty-five patients (mean age = 60, M : F = 26 : 29) with diabetes mellitus underwent renal Doppler ultrasonography. Resistive indices were compared with degree of proteinuria, serum creatinine level, and creatinine clearance rate. Eighteen patients who showed no proteinuria or microscopic proteinuria had a mean resistive index (RI) of 0.72 (SD, 0.05), 16 patients with macroscopic proteinuria without nephrotic syndrome had a mean RI of 0.82 (SD, 0.13), and 21 patients with nephrotic syndrome had a mean RI of 0.90 (SD, 0.12). Renal RI correlated highly with serum creatinine level (r = 0.62) and creatinine clearance rate (r = -0.43). Renal Doppler ultrasonography provides a useful indication of renal function in diabetic nephropathy but cannot offer an advantage over conventional laboratory test

  3. Comprasion of ovarian stromal blood flow measured by color Doppler ultrasonography in polycystic ovary syndrome patients and healthy women with ultrasonographic evidence of polycystic.

    Science.gov (United States)

    Ozdemir, Ozhan; Sari, Mustafa Erkan; Kalkan, Dilek; Koc, Esra Meltem; Ozdemir, Seyda; Atalay, Cemal Resat

    2015-04-01

    To compare ovarian stromal artery blood flows measured by Doppler ultrasonography of polycystic ovary syndrome (PCOS) patients and healthy women with polycystic ovarian image in ultrasonography. Forty-two patients diagnosed with PCOS according to the criteria of 2003 Rotterdam Concencus Conferance on PCOS and 38 healthy volunteers with polycystic ovarian image in ultrasonography were included in the study. Ovarian volumes and ovarian stromal artery blood flows were measured by 3-dimensional (3-D) ultrasonography and Doppler ultrasonography in all patients. In patients with PCOS, ovarian stromal artery pulsatility index (PI) and resistivity index (RI) were found significantly different from healthy women with polycystic ovarian image in ultrasonography (p ovarian volumes were found significantly higher in patients with PCOS (p ovarian volumes and ovarian stromal artery resistivity indices. Ovarian stromal artery Doppler examination could have an importance to explain the pathophysiology of PCOS, but there are few publications in the literature about PCOS and the details of ovarian stromal artery Doppler parameters in patients with polycystic ovarian image only. We conclude that Doppler ultrasonography findings of PCOS patients might be helpful in understanding the clinical follow-up and etiology of the disease.

  4. The image of urachus adenocarcinoma on Doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Oyar, Orhan E-mail: o_oyar@hotmail.com; Yesildag, Ahmet; Gulsoy, Ufuk Kemal; Perk, Hakki

    2002-10-01

    Malignant urachal lesions are exceedingly rare and occur predominantly in adult life. In this case report, an adult patient with urachal carcinoma is presented with abdominal plain film, intravenous urography, gray-scale ultrasonography (US), Doppler US, and computed tomography (CT). Doppler US successfully showed the neovascularity with low resistive index value in the urachus tumor. We believe that Doppler US examination is helpful in the differential diagnosis of urachal carcinoma.

  5. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2012-01-01

    The wrist region is one of the most complex joints of the human body. It is prone to deformity and functional impairment in juvenile idiopathic arthritis (JIA), and is difficult to examine clinically. The aim of this study was to evaluate the role of ultrasonography (US) with Doppler in diagnosis...

  6. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young [Dept. of Radiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  7. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Directory of Open Access Journals (Sweden)

    Ji Young Hwang

    2017-04-01

    Full Text Available Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  8. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Science.gov (United States)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  9. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    International Nuclear Information System (INIS)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions

  10. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Sumit Goel

    2011-01-01

    Full Text Available Aim: To evaluate the efficacy of ultrasonography (USG with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas. There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions.

  11. Prediction of cerebrovascular reserve by the MRI and doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hui Joong; Kim, Yong Sun [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2005-07-15

    We investigated acute stroke patterns on diffusion weighted images and with doppler ultrasonography studies of ICA and MCA steno-occlusive diseases in order to predict the cerbrovascular reserve (CVR), as was measured by acetazolamide (ACZ)-challenged Tc-99m ECD brain perfusion SPECT. A retrospective analysis was performed of 76 patients who underwent MRI/MRA, ACZ-challenged Tc-99m ECD brain perfusion SPECT, and carotid and vertebral artery Doppler sonography. After dividing these patients into four groups-MCA and ICA ateno-occlusions, we analyzed the relationship between the CVR and topologic MR patterns and the flow volume, as was measured by Doppler sonography. The CVRs were preserved in 26 of 76 patients. The CVRs were impaired in those cases of occlusion that were detected on MRA and also by the pattern of the territorial involvement on the diffusion weighted image ({rho} < 0.05, x{sup 2} test). Yet in cases of preserved CVRs, the flow volume of the contralateral ICA, the anterior circulation, and the total cerebral flow volume were increased, as was checked by Doppler sonography ({rho} < 0.05, t-test). As calculated by logistic regression analysis, the accuracy for predicting the preserved CVR by using the statistically significant variables was 78%. We believe that the MRI-SPECT correlation study was helpful for understanding the hemodynamics and topographic patterns of ischemia in patients with ICA and MCA steno-occlusive disease, and that the flow volume measurement, which was done by using duplex US, was useful for predicting the CVR.

  12. Comparison of power Doppler and color Doppler ultrasonography in the detection of intrasticular blood flow of normal infants

    International Nuclear Information System (INIS)

    Shin, Sung Ran; Lee, Ho Kyoung; Lee, Won Gyun; Youk, Dong Joon; Rho, Taek Soo; Lee, Min Jin; Lee, Sang Chun

    1999-01-01

    To compare color Doppler ultrasonography (US) and power Doppler US in the detection of intratesticular blood flow in normal infants and to asses the symmetry of blood flow. Testicular blood flow was assessed prospectively in 100 testes of 50 infants with both power and color Doppler US. We compared the power Doppler with color Doppler to detect intratesticular blood. When the flow was detected, intratesticular blood flow was graded as follows: grade 1: single intratesticular Doppler signal ; grade 2: multiple intratesticular Doppler signals. The symmetry of intratesticular flow was assessed by using the same method. Intratesticular flow was detected in 72 (72%) and 68 (68%) testes on power and color Doppler US, respectively. In 76 testes (76%), intratesticular flow was detected in either one or both techniques. On power Doppler US, grade 1 was seen in 40 tests and grade 2 in 32 testes. On color Doppler US, grade 1 was noted in 52 testes and grade 2 in 16 testes. Testicular blood flow was symmetric on both power and color Doppler US in each patient. There was no difference between power Doppler and color Doppler ultrasonography in detecting intratesticular blood flow in normal infants.

  13. Granulomatous Prostatitis: Gray-scale Transrectal Ultrasonography and Color Doppler Ultrasonography Findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Jung; Lim, Joo Won; Lee, Dong Ho; Ko, Young Tae; Kim, Eui Jong [Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2007-12-15

    We report here three cases of granulomatous prostatitis. All cases were confirmed by a transrectal ultrasonography (TRUS)-guided core biopsy of the prostate. Two cases received intravesical BCG therapy for a bladder tumor, and one case had no known predisposing condition. Gray-scale TRUS showed low echoic nodules in the outer gland in all cases. Color Doppler ultrasonography (CDUS) showed several dot-like blood flows within the low echoic nodules in two cases and several dot-like blood flows and short linear blood flows within the low echoic nodules in one case. Gray-scale TRUS findings of granulomatous prostatitis are similar to findings of prostate cancer. On CDUS, several dot-like blood flows or short linear blood flows were noted within the low echoic nodules in patients with granulomatous prostatitis. If low echoic nodules with dot-like or short linear blood flows are noted in patients with genitourinary tract tuberculosis or previous BCG therapy, granulomatous prostatitis should be included in the differential diagnosis. However, a prostatic biopsy is required for a final diagnosis

  14. Transcranial Doppler ultrasonography predicts cardiovascular events after TIA

    International Nuclear Information System (INIS)

    Holzer, Katrin; Sadikovic, Suwad; Esposito, Lorena; Bockelbrink, Angelina; Sander, Dirk; Hemmer, Bernhard; Poppert, Holger

    2009-01-01

    Transient ischemic attack (TIA) patients are at high vascular risk. We assessed the value of extracranial (ECD) and transcranial (TCD) Doppler and duplex ultrasonography to predict clinical outcome after TIA. 176 consecutive TIA patients admitted to the Stroke Unit were recruited in the study. All patients received diffusion-weighted imaging, standardized ECD and TCD. At a median follow-up of 27 months, new vascular events were recorded. 22 (13.8%) patients experienced an ischemic stroke or TIA, 5 (3.1%) a myocardial infarction or acute coronary syndrome, and 5 (3.1%) underwent arterial revascularization. ECD revealed extracranial ≥ 50% stenosis or occlusions in 34 (19.3%) patients, TCD showed intracranial stenosis in 15 (9.2%) and collateral flow patterns due to extracranial stenosis in 5 (3.1%) cases. Multivariate analysis identified these abnormal ECD and TCD findings as predictors of new cerebral ischemic events (ECD: hazard ratio (HR) 4.30, 95% confidence interval (CI) 1.75 to 10.57, P = 0.01; TCD: HR 4.73, 95% CI 1.86 to 12.04, P = 0.01). Abnormal TCD findings were also predictive of cardiovascular ischemic events (HR 18.51, 95% CI 3.49 to 98.24, P = 0.001). TIA patients with abnormal TCD findings are at high risk to develop further cerebral and cardiovascular ischemic events

  15. Evaluation of the activity of synovitis in patients with rheumatoid arthritis: Value of power Doppler ultrasonography

    International Nuclear Information System (INIS)

    Ahn, Joong Mo; Lim, Hyo Keun; Kim, Seung Hoon; Kim, Sung Hyun; Koh, Eun Mi; Kim, Jin Seok; Cha, Hoon Suk

    2001-01-01

    To correlate the grades on power Doppler ultrasonography with clinical disease activity indices and acute phase reactant values for assessing the activity of synovitis in patients with rheumatoid arthritis. Twenty patients with rheumatoid arthritis diagnosed on the basis of American College of power Doppler ultrasonography. Two experienced radiologists evaluated, in consensus, the power Doppler signals as follows: grade I=no flow or minimal flow, grade 2=mild flow, grade 3=moderate flow and grade 4= marked flow. The clinical disease activity indices consisted of the counts of tender joints and swollen joints, patient's assessment of pain, patient's global assessment of disease activity, physician's globe assessment of disease activity and patient's assessment of physical function. Acute-phase reactants included CRP and ESR. The grades on power Doppler ultrasonography were correlated with clinical disease activity indices as well as acute-phases reactant values by a use of Spearman rank correlation coefficient. The grades on power Doppler ultrasonography showed a statistically significant correlation with tender joint count (rs=.835; p<.05), swollen joint count (rs=.833; p<.05), physician's global assessment of disease activity (rs=.857; p<.05), CRP (rs=.838; P<.05) and ESR (rs=.838; p<.05). The power Doppler ultrasonography is an useful diagnostic modality for assessing the activity of synovitis in patients with rheumatoid arthritis.

  16. Color Doppler Ultrasonography-Targeted Perforator Mapping and Angiosome-Based Flap Reconstruction

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Tei, Troels; Thomsen, Jørn Bo

    2016-01-01

    Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap reconstr......Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap...

  17. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    International Nuclear Information System (INIS)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D'Ippolito, Giuseppe; Colleoni, Ramiro

    2008-01-01

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  18. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: ar.leao@uol.com.br; Colleoni, Ramiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Gastroenterologia

    2008-09-15

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  19. Determination of intestinal viability by Doppler ultrasonography in venous infarction.

    Science.gov (United States)

    Cooperman, M; Martin, E W; Carey, L C

    1980-01-01

    The accuracy of Doppler ultrasound in predicting the viability of ischemic intestine secondary to venous obstruction was assessed. Twenty loops of ischemic intestine were created in dogs by temporarily obstructing venous return from the bowel. Doppler arterial flow signals within the intestine quickly disappeared following venous occlusion. In ten segments, arterial signals promptly returned following release of venous occlusion. Nine of these ten segments were viable at reoperation 24 hours later. In ten segments, no arterial signals could be detected following release of venous occlusion, and only one segment proved to be viable. Doppler ultrasound findings were far more accurate in distinguishing between viable and nonviable intestine thatn were clinical guides to intestinal viability. PMID:7352777

  20. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    Energy Technology Data Exchange (ETDEWEB)

    Ayaz, Tunahan; Akansel, Gur. E-mail: gakansel@superonline.com; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-06-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia.

  1. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    International Nuclear Information System (INIS)

    Ayaz, Tunahan; Akansel, Gur.; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-01-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia

  2. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2011-01-01

    hypertrophy, effusion) and by color Doppler (synovial hyperemia) before and 4 weeks after US-guided steroid injection. Results US detected 121 compartments with active disease (joints, tendon sheaths and 1 ganglion cyst). Multiple compartments were involved in 80% of the ankle regions. The talo-crural joint...

  3. The role of Doppler ultrasonography in the evaluation of the renal function

    International Nuclear Information System (INIS)

    Krasteva, R.; Kiperova, B.; Andreev, E.; Kostadinova, I.; Petrov, T.; Hadjidekov, V.; Simeonova, A.

    2008-01-01

    The purpose of the study was to evaluate Doppler ultrasonography in the detection of the renal function. Sixty six patients with unilateral kidney changes were enrolled in this prospective study. 16 had hypoplastic kidney, 24 had hypofunctioned kidney and 26 had afunctioned kidney. 15 healthy potential donors were controls. A dynamic renal scintigraphy was performed with 74-111 MBq 99mTc-MAG3. The Color, Pulsed and Power Doppler were performed. The Vp and δVp derived from the spectrum of the segmental arteries were measured during Pulsed Doppler examination. There are not any difference between kidneys of health and hypoplastic kidneys on color and Power Doppler. The hypofunctioning kidneys had reduced blood flow and afunctioning kidneys had markedly reduced blood flow. The Vp of donors (48.8±7.6) and Vp of hypoplastic kidneys (49.9±4.8) were significantly higher compared to Vp of hypofunctioning kidneys (31.6±10.0) and to Vp of afunctioning kidneys (26.6±9.1), (p 14.5 cm/s in 93%, and from hypofunctioning kidney by delta Vp>10.5 cm/s in 87%. The Doppler ultrasonography is very useful in the evaluation of renal function. The changes of the Doppler parameters accurately marked the loss of function which can not be detected by elevation of the creatinine level. (authors)

  4. The Efficacy of Magnetic Resonance Imaging and Color Doppler Ultrasonography in Diagnosis of Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    Behrooz Davachi

    2014-12-01

    Full Text Available Background and aims. Although salivary gland tumors are not very common, early diagnosis and treatment is crucial because of their proximity to vital organs, and therefore, determining the efficacy of new imaging procedures becomes important. This study aimed to evaluate the efficacy of magnetic resonance imaging (MRI and color doppler ultrasonography parameters in the diagnosis and differentiation of benign and malignant salivary gland tumors. Materials and methods. In this cross-sectional study, color doppler ultrasonography and MRI were performed for 22 patients with salivary gland tumor. Demographic data as well as MRI, color doppler ultrasonography, and surgical parameters including tumor site, signal in MRI images, ultrasound echo, tumor border, lymphadenopathy, invasion, perfusion, vascular resistance index (RI, vascular pulse index (PI were analyzed using Chi-square test, Fisher’s exact test, and independent ttest. Results. The mean age of patients was 46.59±13.97 years (8 males and 14 females. Patients with malignant tumors were older (P < 0.01. The most common tumors were pleomorphic adenoma (36.4%, metastasis (36.4%, and mucoepidermoid carcinoma (9%. Nine tumors (40.9% were benign and 13 (59.1% were malignant. The overall accuracy of MRI and color doppler ultrasonography in determining tumor site was 100% and 95%, respectively. No significant difference observed between RI and PI and the diagnosis of tumor. Conclusion. Both MRI and ultrasonography have high accuracy in the localization of tumors. Well-identified border was a sign of benign tumors. Also, invasion to adjacent structures was a predictive factor for malignancy.

  5. The color Doppler ultrasonography in in the diagnosis of deep vein thrombosis

    International Nuclear Information System (INIS)

    Ameneiro Perez, Santiago; Alvarez Sanchez, Jose A.; Rodriguez Villalonga, Luis; Borras Migues, Marisela; Quinnones Castro, Mayda

    2004-01-01

    The paper was aimed at evaluating the accuracy of color Doppler ultrasonography, a noninvasive method, in the diagnosis of deep vein thrombosis of the lower limbs, comparing it to the results of the cruel and costly diagnostic g olden rule , that is, phlebography. Methods: Color Doppler ultrasonography served to assess 102 patients clinically suspected of deep vein thrombosis of the lower limbs, taking into account the following criteria: vein compressibility, echographic images, color, Vein Doppler signal modulation after several maneuvers and distal compression. Sensitivity, specificity, positive and negative predictive values and diagnostic efficacy were estimated for each criteria, taking the phlebography as a reference. Results: Total or partial lack of vein compressibility combined with the vein flow evaluation is the ultrasonographic criterion that reveals higher degree of sensitivity, specificity and efficacy (0,98; 0,95 and 0,97 respectively. Color Doppler ultrasonography is a highly effective noninvasive diagnostic method that detects deep vein thrombosis in proximal areas of the lower limbs

  6. Doppler ultrasonography of the pectinis oculi artery in harpy eagles (Harpia harpyja

    Directory of Open Access Journals (Sweden)

    Wanderlei de Moraes

    2017-03-01

    Full Text Available Twenty harpy eagles (Harpia harpyja without systemic or ocular diseases were examined to measure blood velocity parameters of the pectinis oculi artery using Doppler ultrasonography. Pectinate artery resistive index (RI and pulsatility index (PI were investigated using ocular Doppler ultrasonography. The mean RI and PI values across all eyes were 0.44±0.10 and 0.62±0.20 respectively. Low RI and PI values found in the harpy eagle´s pectinis oculi artery compared with the American pekin ducks one and other tissue suggest indeed a high metabolic activity in pecten oculi and corroborates the hypothesis of a nutritional function and/or intraocular pressure regulation.

  7. Comparison between doppler ultrasonography and renal scintigraphy in assessment of post-transplant renal function

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yeo Chang; Shin, Byung Seok; Ohm, Joon Young; Kim, Seong Min; Ahn, Moon Sang; Yang, Shin Seok [Chungnam National University Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dept. of Radiology, Dankook University Hospital, Cheonan (Korea, Republic of)

    2016-05-15

    To compare the usefulness of Doppler ultrasonography and renal scintigraphy in the assessment of short- and long-term function of transplanted kidneys. We retrospectively reviewed the cases of 79 patients who underwent Doppler ultrasonography and technetium-99m diethylene triamine pentaacetic acid renal scintigraphy on the same day, within 4 days of renal transplantation. Image parameters were evaluated for statistical differences. There was a strong positive correlation between the glomerular filtration rate (GFR) as measured by renal scintigraphy and the estimated GFR (eGFR) based on serum creatinine levels (correlation coefficient = 0.71). Scan grade according to the time-activity curve, resistive index, and end diastolic velocity showed moderate correlations with the eGFR (correlation coefficients = -0.557, -0.329, and 0.370, respectively) in the early post-transplantation period. The mean survival time was longer in patients with lower resistive indices (≤ 0.68, 54.9 months vs. > 0.68, 29.5 months) and lower pulsatility indices (≤ 1.32, 53.8 months vs. > 1.32, 28.7 months); however, there were no statistically significant differences in the long-term follow-up period (p = 0.121 for resistive index and p = 0.074 for pulsatility index). Renal scintigraphy is a more sensitive method than Doppler ultrasonography for assessing transplanted kidney function in the early post-transplantation period. Doppler ultrasonography might reflect the long-term survival time. However, it is difficult to predict long-term renal function using either method.

  8. Comparison between doppler ultrasonography and renal scintigraphy in assessment of post-transplant renal function

    International Nuclear Information System (INIS)

    Yoon, Yeo Chang; Shin, Byung Seok; Ohm, Joon Young; Kim, Seong Min; Ahn, Moon Sang; Yang, Shin Seok; Park, Mi Hyun

    2016-01-01

    To compare the usefulness of Doppler ultrasonography and renal scintigraphy in the assessment of short- and long-term function of transplanted kidneys. We retrospectively reviewed the cases of 79 patients who underwent Doppler ultrasonography and technetium-99m diethylene triamine pentaacetic acid renal scintigraphy on the same day, within 4 days of renal transplantation. Image parameters were evaluated for statistical differences. There was a strong positive correlation between the glomerular filtration rate (GFR) as measured by renal scintigraphy and the estimated GFR (eGFR) based on serum creatinine levels (correlation coefficient = 0.71). Scan grade according to the time-activity curve, resistive index, and end diastolic velocity showed moderate correlations with the eGFR (correlation coefficients = -0.557, -0.329, and 0.370, respectively) in the early post-transplantation period. The mean survival time was longer in patients with lower resistive indices (≤ 0.68, 54.9 months vs. > 0.68, 29.5 months) and lower pulsatility indices (≤ 1.32, 53.8 months vs. > 1.32, 28.7 months); however, there were no statistically significant differences in the long-term follow-up period (p = 0.121 for resistive index and p = 0.074 for pulsatility index). Renal scintigraphy is a more sensitive method than Doppler ultrasonography for assessing transplanted kidney function in the early post-transplantation period. Doppler ultrasonography might reflect the long-term survival time. However, it is difficult to predict long-term renal function using either method

  9. Ovarian and uterine periovulatory Doppler ultrasonography in bitches

    Directory of Open Access Journals (Sweden)

    Claudia C. Barbosa

    2013-09-01

    Full Text Available This paper aims to describe the uterine and ovarian ultrasonographic characteristics and Doppler velocimetric features of their arteries in bitches during the periovulatory period. Fifteen estrous cycles in 10 animals were evaluated. The ultrasonographic characteristics, resistance indices (RI and pulsatility indices (PI of the uterus and ovaries in each animal were recorded 5 days before and after ovulation (D0. The data were statistically analyzed, and the results were expressed as the mean ± standard error of mean (P<0.05. In results the ultrasonographic features of the uterus were the same on all of the cycles and evaluated days. The uterus had an average diameter of 0.85±0.02cm. An increase in the volume of the ovaries and the diameter of the ovarian follicles were measured. Ovaries had a volume of 0.64±0.06cm³, and the follicles cavities had a diameter of 0.46 ± 0.01 cm on the day of ovulation. After ovulation, it was observed that some follicles not collapse in some cycles. Two days prior to ovulation, the uterine blood perfusion decreased. This decrease remained unchanged until ovulation. Following ovulation, we measured a gradual increase in the uterine perfusion and in the ovarian artery. This artery directed blood flow to the ovaries and increased the intra-ovarian perfusion on the day after ovulation. In conclusion, specific features are observed in the uterus and ovarian ultrasound image and Doppler values of their arteries presented on the periovulatory days and when associated allow to estimate more accurately the date of ovulation.

  10. Clinical application of transcranial Doppler ultrasonography in premature, very-low-birth-weight neonates

    International Nuclear Information System (INIS)

    Gabriel, Marta Lucia; Souza, Antonio Soares

    2010-01-01

    Objective: the present study was aimed at analyzing the value of the early diagnosis of hemodynamic changes in hemorrhages and hypoxic-ischemic events in premature, very-low-birth-weight neonates through the evaluation of images and resistance index measurement by means of transcranial Doppler ultrasonography. Materials and methods: fifty premature, very-low-birth-weight neonates were submitted to transcranial Doppler ultrasonography with sequential transfontanellar and transtemporal techniques. Results: cerebral abnormalities were detected in 32% of the neonates (22% with intracranial hemorrhage, 8% with periventricular leukomalacia, and 2% with toxoplasmosis). Among the 34 cases (68%) of neonates in whom no brain lesion was detected at transcranial Doppler ultrasonography, 18 (53%) presented changes in the resistance index. Such resistance index varied according to the time of the examination. Conclusion: there is a correlation between the presence of cerebral hemodynamic changes demonstrated by resistance index measurements and the subsequent development of hemorrhages and hypoxic-ischemic lesions. Although not being a death predictor, changes in the resistance index are associated with the severity of the clinical conditions in preterm, very-low-birth-weight neonates. (author)

  11. Clinical application of transcranial Doppler ultrasonography in premature, very-low-birth-weight neonates

    Energy Technology Data Exchange (ETDEWEB)

    Gabriel, Marta Lucia [Fundacao Faculdade Regional de Medicina (FUNFARME), Sao Jose do Rio Preto, SP (Brazil). Hospital de Base; Piatto, Vania Belintani [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil); Souza, Antonio Soares, E-mail: depimagem@famerp.b [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Dept. de Diagnostico por Imagem

    2010-07-15

    Objective: the present study was aimed at analyzing the value of the early diagnosis of hemodynamic changes in hemorrhages and hypoxic-ischemic events in premature, very-low-birth-weight neonates through the evaluation of images and resistance index measurement by means of transcranial Doppler ultrasonography. Materials and methods: fifty premature, very-low-birth-weight neonates were submitted to transcranial Doppler ultrasonography with sequential transfontanellar and transtemporal techniques. Results: cerebral abnormalities were detected in 32% of the neonates (22% with intracranial hemorrhage, 8% with periventricular leukomalacia, and 2% with toxoplasmosis). Among the 34 cases (68%) of neonates in whom no brain lesion was detected at transcranial Doppler ultrasonography, 18 (53%) presented changes in the resistance index. Such resistance index varied according to the time of the examination. Conclusion: there is a correlation between the presence of cerebral hemodynamic changes demonstrated by resistance index measurements and the subsequent development of hemorrhages and hypoxic-ischemic lesions. Although not being a death predictor, changes in the resistance index are associated with the severity of the clinical conditions in preterm, very-low-birth-weight neonates. (author)

  12. Renal duplex doppler ultrasonography in patients with recurrent urinary tract infection

    Directory of Open Access Journals (Sweden)

    Soliman Neveen

    2009-01-01

    Full Text Available Renal hemodynamics were studied using duplex Doppler ultrasonography in forty (33 females and 7 males; mean age: 12.1 ± 5.3 years normotensive patients with recurrent urinary tract infection and with no evidence of obstructive uropathy and age matched control group of 24 healthy children and adolescents. Resistivity index (RI and pulsatility index (PI in both arcuate (AA and interlobar (IA arteries were significantly higher in patients as compared to controls (P= 0.001, 0.01 respectively. Diastolic/systolic ratio (D/S at the same levels of renal vasculature (AA and IA was significantly lower in study patients as compared to their controls (P= 0.01, 0.001 respectively. Moreover, scarred renal units had higher RI and PI values as well as lower D/S ratio as compared to non scarred units (p= 0.01, 0.001, 0.001 respectively.. In conclusion, intra renal vascular resistivity is significantly increased in recurrent UTI patients particularly in those sus-taining renal scarring. Further follow up studies are recommended to determine if duplex assess-ment of intrarenal vasculature could be useful as an ancillary diagnostic and/or prognostic technique in the evaluation and follow up of recurrent UTI.

  13. Comparative analysis of pulsed doppler ultrasonography of portal vein vs indirect photography

    International Nuclear Information System (INIS)

    Chang, Jae Chun; Kwon, Huck Po; Hwang, Mi Soo; Kim, Sun Youn; Park, Bok Hwan; Lee, Hyun Ju; Kim, Hong Jin

    1990-01-01

    There are some limitation of interpretation in indirect photography via superior mesenteric artery. In order to supplement and predict indirect photography, we compared indirect photographic findings with pulsed doppler flowmetry in 38 hepatobiliary patients, and the results were as follow: 1. In case of normal main portal vein(MPV) filling, Pulsed Doppler always showed antegrade, continuous parabolic wave form and cases of abnormal MPV filling, showed unusual wave form and flow direction. 2. In normal filling case of proximal right portal vein, Pulsed Doppler almost showed normal continuous parabolic wave form but in normal filling cases of proximal left portal vein, occasionally showed undulating wave form. 3. In each side proximal portal vein abnormal filling case, we could observe abnormal doppler wave form and could obtain additional information using doppler wave form. 4. Mean portal flow velocity was significantly increased in higher photography grade(p=0.01) and congestion index was significantly decreased in higher photography grade(p=0.01). 5. We concluded that doppler ultrasonography could supplement incomplete indirect photography

  14. Validity of colour doppler ultrasonography with d-dimers in clinically suspected deep venous thrombosis of the lower limb

    International Nuclear Information System (INIS)

    Babar, T.H.; Nafees, M.N.; Sarwar, S.; Ashraf, N.

    2010-01-01

    Objective: This study was designed to evaluate the validity of colour Doppler ultrasonography with D-dimers in clinically suspected deep venous thrombosis of the lower limb. Study Design: Validation study Place and Duration of study: Radiology Department CMH/MH Rawalpindi Six months from 15 June 2006 to 31 December 2006. Subjects and Methods: Thirty cases of clinically suspected deep venous thrombosis of the lower limb were included in the study selected on non probability convenience sampling technique. Colour Doppler ultrasonography examination of the affected lower limb was carried out and results compared with D-dimers assays results. Results: Among 30 patients who underwent colour Doppler ultrasonography examination of the affected limb for diagnosis of deep venous thrombosis, 27 (90%) were diagnosed to have deep venous thrombosis, 3 (10%) were diagnosed not to have deep venous thrombosis. Amongst them 2 patients had raised D-dimers levels and repeat Doppler ultrasound advised. On revised ultrasound deep venous thrombosis in these patients was confirmed. This showed that colour Doppler ultrasonography examination has sensitivity of 93.1%, specificity 100%, positive predictive value 100%, negative predictive value 33.33% and overall accuracy of 93.33 %. Conclusion: Colour Doppler ultrasonography has a high diagnostic yield in cases of deep venous thrombosis of lower limb when used in conjunction with D-dimers assays. (author)

  15. Contrast-enhanced power Doppler ultrasonography of the metacarpophalangeal joints in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Court-Payen, Michel; Strandberg, Charlotte

    2003-01-01

    The aim of this study was to examine, with dynamic contrast-enhanced MRI as the reference, if contrast-enhanced power Doppler ultrasonography (CE PDUS) of rheumatoid arthritis (RA) metacarpophalangeal (MCP) joints provides additional information for evaluation of synovial inflammation compared...... with PDUS. One MCP joint in each of 15 RA patients and 3 healthy control persons were examined with PDUS before and after intravenous bolus Levovist contrast injection. Corresponding rates of early synovial enhancement (RESE), previously shown to be closely related to histopathological synovitis, were...... calculated from dynamic contrast-enhanced MR images obtained the same day. Prior to ultrasonography, the joint was evaluated clinically. Levovist increased the flow signal in 7 of 9 joints with pre-contrast flow-signal and in 0 of 9 without pre-contrast signal. No healthy controls showed CE PDUS signal...

  16. The effect of TACE with endostatin on hemodynamics in hepatic implantation tumor using Doppler ultrasonography

    International Nuclear Information System (INIS)

    Zhou Guangli; Wu Yuanyuan; Wang Bin; Liu Yan; Zheng Chuanli; Sang Li; Liu Feng

    2009-01-01

    Objective: To investigate the hemodynamic changes in the rabbit liver and VX2 hepatic implantation tumor after treatment by transcatheter arterial chemoembolization (TACE)/endostatin using Doppler ultrasonography. Methods: Twenty rabbits with VX2 hepatic tumor were randomly distributed into the control group (n=10) and the anti- angiogenesis group (n=10). The rabbits were administered with endostatin and adriamycin-lipiodol in the anti-angiogenesis group and with 37℃ saline in the control group via hepatic artery. The hemodynamic changes of the tumors, hepatic artery, and portal vein were recorded with Doppler ultrasonography 1 week after the treatment. The results before and after the treatment were compared. Results: In the control group, the maximal hepatic artery blood flow velocity was significantly higher than that before the treatment (P<0.05). However, the resistance index and the portal vein blood flow velocities had no significantly change compared with those before the treatment (P>0.05). In the anti-angiogenesis group, the hepatic artery blood flow velocity was significantly lower than that before the treatment (P<0.05), and the resistance index was increased (P<0.05). However, the portal vein blood flow velocity had no significantly change (P>0.05). The blood flow signal in all tumors was rich before embolization. After TACE, the blood flow signal was significantly decreased, even partly disappeared in the anti-angiogenesis group. Conclusion: TACE with endostatin can effectively block the blood supplement of VX2 hepatic implantation tumor. Doppler ultrasonography can detected the blood flow changes and can be used in evaluating the therapeutic effect in hepatic implantation tumor. (authors)

  17. The Role of Color Doppler Ultrasonography in Characterization of Thyroid Tumors

    International Nuclear Information System (INIS)

    Kim, Hee Soo; Jeon, Pyong; Won, Jong Yoon; Na, Jae Beom; Lee, Hyang Mee; Yoo, Hyung Sik; Lee, Jong Tae; Park, Jeong Soo; Cho, Nam Hoon

    1995-01-01

    To assess the usefulness of color Doppler ultrasonography in the characterization of thyroid tumors, surgically proven 88 nodules in 85 patients were evaluated. Using 10 MHz linear array transducer, gray scale images were initially evaluated. Then, distribution pattern of color signals (marginal, intra-tumoral, mixed) and graded internal vascularity according to morphology of color signal (0:absence of internal signal, 1: spotty, 2: linear,3: branching) were observed on color doppler imaging. Pulsed doppler waves were analyzed with parameters including peak systolic velocity(PSV), resistive index(RI), and pulsatile index(PI). Significantly larger numbers of intra-tumoral type, 20 cases(62.5%), were observed in malignant nodules, whereas mixed forms were predominant in benign group, 37 cases (66%) In graded internal vascularity, malignant nodules tended to have grade 2 or 3 signals, whereas benign nodules tended to have grade 0 or 1 signals. Spectral wave analysis show no significant difference in the value of PSV, RI, and PI between malignancy and benignity group. In conclusion, color Doppler imaging has a potential role in the characterization of thyroid nodules as a supportive method for gray scale diagnosis

  18. Diagnosis of post-partum ovarian vein thrombophlebitis by color Doppler ultrasonography: about 10 cases.

    Science.gov (United States)

    Giraud, J R; Poulain, P; Renaud-Giono, A; Darnault, J P; Proudhon, J F; Grall, J Y; Mocquet, P Y

    1997-09-01

    Post-partum ovarian vein thrombosis is often overlooked or mistaken for other complications such as endometritis. Color Doppler ultrasonography is a very good diagnostic method when properly indicated and correctly interpreted according to clinical data. This study reports ten cases that were retrospectively studied, during which color Doppler ultrasonography was used. The clinical signs and the results are reviewed. The lesions were clearly visualized in eight of the ten cases; one of the two failures resulted from a methodological fault (uninterpretable result); the other one was due to the lack of experience of the operator and nonrecognition of the clinical signs. Thrombosis appears as a hypoechogenic and tubular image. This type of examination is particularly indicated in the presence of certain clinical signs that were observed in our cases: fever and iliac pain are the main precursor signs, often associated with abdominal meteorism and slow digestive transit; provoked cul-de-sac pain during vaginal probing was the only constant sign, sometimes associated with painful swelling.

  19. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    Science.gov (United States)

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial

  20. Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models

    Directory of Open Access Journals (Sweden)

    Anderson Chun On Tsang

    2015-04-01

    Full Text Available Purpose: The aim of this study was to validate a computational fluid dynamics (CFD simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. Results: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. Conclusion: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents.

  1. Dynamics of contrast enhancement in MR imaging and power Doppler ultrasonography of solid breast lesions

    International Nuclear Information System (INIS)

    Reinikainen, H.; Paeaekkoe, E.; Suramo, I.; Paeivaensalo, M.; Rissanen, T.

    2002-01-01

    Purpose: To evaluate the dynamics of contrast enhancement in solid breast lesions at contrast-enhanced MR imaging and power Doppler ultrasonography (US) and to compare the methods to histology and to each other. Material and Methods: Forty breast lesions were prospectively examined with dynamic MR and power Doppler US. Time-signal intensity curves of enhancement were obtained for both methods. The shape of the curve was analyzed to be benign, indeterminate or malignant. The curves were also analyzed quantitatively by calculating the slope of the curve and the area under the curve (both methods), relative enhancement (MR), and time to peak (US). The lesions were divided into malignant lesions, fibroadenomas, and other benign lesions. The results were compared to histology. Results: In the subjective analysis of the MR curve in differentiating between benign and malignant lesions the accuracy was 90%. The MR curve also enabled differentiation between fibroadenomas and malignancies. The accuracy of the US curve was 38%. Quantitatively, statistically significant differences were found using all the MR variables, except between malignancies and fibroadenomas. Using the US variables, no significant difference was found between the groups. Conclusion: The dynamics of contrast-enhanced MR were reliable in the differential diagnosis of solid breast lesions, but contrast-enhanced power Doppler US was of limited value

  2. Assessment of cerebral circulation in normal fetuses by three-dimensional power Doppler ultrasonography

    International Nuclear Information System (INIS)

    Milani, Hérbene José Figuinha; Sá Barreto, Enoch Quinderé de; Araujo Júnior, Edward; Haratz, Karina Krajden; Rolo, Liliam Cristine; Nardozza, Luciano Marcondes Machado; Moron, Antonio Fernandes

    2012-01-01

    Objective: To assess the three-dimensional power Doppler ultrasonography (3D power Doppler) vascular indices in the middle cerebral artery (MCA), anterior cerebral artery (ACA) and posterior cerebral artery (PCA) territories. Methods: A cross-sectional study was carried out on 111 normal pregnancies between 26 and 34 weeks. The MCA, ACA and PCA territories closest to the transducer were scanned and volumes were calculated by using the VOCAL (Virtual Organ Computer-aided Analysis) program. The 3D power Doppler indices – vascularization index (VI), flow index (FI) and vascularization-flow index (VFI) were calculated. Scatter graphs, Pearson correlation coefficients (r) and linear regression models were used. Results: Only the FI-MCA (r = 0.38 and p < 0.001), VFI-MCA (r = 0.23 and p = 0.016) and FI-PCA (r = 0.191 and p = 0.040) had a low correlation with gestational age. The other 3D power Doppler indices VI-MCA (r = 0.153 and p = 0.150), VI-ACA (r = 0.105 and p = 0.271), FI-ACA (r = 0.154 and p = 0.106), VFI-ACA (r = 0.134 and p = 0.161), VI-PCA (r = 0.105 and p = 0.270) and VFI-PCA (r = 0.126 and p = 0.180) showed no statistically significant correlation with gestational. Conclusion: It was observed a low correlation between gestational age and the FI-MCA, VFI-MCA and FI-PCA.

  3. Colour Doppler Ultrasonography as a Tool to Assess Luteal Function in Santa Inês Ewes.

    Science.gov (United States)

    Figueira, L M; Fonseca, J F; Arashiro, Ekn; Souza-Fabjan, Jmg; Ribeiro, Acs; Oba, E; Viana, Jhm; Brandão, F Z

    2015-08-01

    The aim of this study was to evaluate luteal dynamics in the Santa Inês ewes using colour Doppler (CD) ultrasonography. Oestrus was synchronized in nulliparous females (n = 18), and subsequently, they were only teased (n = 6) or teased and mated (n = 12). Blood samples were collected daily for plasma progesterone (P4 ) concentrations. Ultrasonographic images of corpora lutea (CL) in CD mode were obtained for further analysis in its largest diameter. The CD mode allowed an early sequential monitoring of CL that was visualized by the first time 0.77 ± 0.62 days after ovulation, with luteal area 29.68 ± 13.21 mm(2) . During the luteogenesis, a progressive increase was observed, followed by a plateau of luteal area, vascularization area and plasma concentrations of P4 reaching maximum values in D11 (124.0 ± 38.0 mm(2) , 52.78 ± 24.08 mm(2) and 11.23 ± 4.89 ng/ml, respectively). In the luteolysis, the plasma concentrations of P4 decreased sharply, whereas luteal and vascularization area gradually. The vascularization area was positively correlated with plasma concentrations of P4 during the luteogenesis (r = 0.22) and luteolysis (r = 0.48). The luteal dynamics of Santa Inês ewes showed patterns similar to those observed in other sheep breeds studied. The CD ultrasonography has the potential to be used as a tool to assess luteal function in sheep. © 2015 Blackwell Verlag GmbH.

  4. Ultrasonography and color Doppler of proximal gluteal enthesitis in juvenile idiopathic arthritis: a descriptive study

    Directory of Open Access Journals (Sweden)

    Thomsen Carsten

    2011-08-01

    Full Text Available Abstract Background The presence of enthesitis (insertional inflammation in patients with juvenile idiopathic arthritis (JIA is difficult to establish clinically and may influence classification and treatment of the disease. We used ultrasonography (US and color Doppler (CD imaging to detect enthesitis at the small and deep-seated proximal insertion of the gluteus medius fascia on the posterior iliac crest where clinical diagnosis is difficult. The findings in JIA patients were compared with those obtained in healthy controls and with the patients' MRI results. Methods Seventy-six proximal gluteus medius insertions were studied clinically (tenderness to palpation of the posterior iliac crest and by US and CD (echogenicity, thickness, hyperemia in 38 patients with JIA and in 38 healthy controls, respectively (median age 13 years, range 7-18 years. In addition, an additional MRI examination of the sacroiliac joints and iliac crests was performed in all patients. Results In patients with focal, palpable tenderness, US detected decreased echogenicity of the entheses in 53% of the iliac crests (bilateral in 37% and unilateral in 32%. US also revealed significantly thicker entheses in JIA patients compared to healthy controls (p Conclusions According to US, the gluteus medius insertion was thicker in JIA patients than in controls, and it was hypoechoic (enthesitis in about half of the patients. These findings may represent chronic, inactive disease in some of the patients, because there was only limited Doppler flow and MRI contrast enhancement. The present study indicates that US can be useful as an adjunct to clinical examination for improved assessment of enthesitis in JIA. This may influence disease classification, ambition to treat, and choice of treatment regimen.

  5. Evaluation of arterial digital blood flow using Doppler ultrasonography in healthy dairy cows.

    Science.gov (United States)

    Müller, H; Heinrich, M; Mielenz, N; Reese, S; Steiner, A; Starke, A

    2017-06-06

    Local circulatory disturbances have been implicated in the development of foot disorders in cattle. The goals of this study were to evaluate the suitability of the interdigital artery in the pastern region in both hind limbs using pulsed-wave (PW) Doppler ultrasonography and to investigate quantitative arterial blood flow variables at that site in dairy cows. An Esaote MyLabOne ultrasound machine with a 10-MHz linear transducer was used to assess blood flow in the interdigital artery in the pastern region in both hind limbs of 22 healthy German Holstein cows. The cows originated from three commercial farms and were restrained in a standing hoof trimming chute without sedation. A PW Doppler signal suitable for analysis was obtained in 17 of 22 cows. The blood flow profiles were categorised into four curve types, and the following quantitative variables were measured in three uniform cardiac cycles: vessel diameter, pulse rate, maximum systolic velocity, maximum diastolic velocity, end-diastolic velocity, reverse velocity, maximum time-averaged mean velocity, blood flow rate, resistance index and persistence index. The measurements did not differ among cows from the three farms. Maximum systolic velocity, vessel diameter and pulse rate did not differ but other variables differed significantly among blood flow profiles. Differences in weight-bearing are thought to be responsible for the normal variability of blood flow profiles in healthy cows. The scanning technique used in this report for evaluation of blood flow in the interdigital artery appears suitable for further investigations in healthy and in lame cows.

  6. Power Doppler ultrasonography for assessment of synovitis in the metacarpophalangeal joints of patients with rheumatoid arthritis: a comparison with dynamic magnetic resonance imaging

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Court-Payen, M; Strandberg, C

    2001-01-01

    OBJECTIVE: To evaluate the effectiveness of power Doppler ultrasonography (PDUS) for assessing inflammatory activity in the metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA), using dynamic magnetic resonance imaging (MRI) as a reference method. METHODS: PDUS and dynamic ...

  7. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    OpenAIRE

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in f...

  8. Hyperdynamic circulatory changes in liver cirrhosis: Comparative evaluation by doppler ultrasonography with normal subjects

    International Nuclear Information System (INIS)

    Im, Dae Wook; Baik, Soon Koo; Suh, Jung In; Kim, Jae Woo; Park, Yong Soon; Kim, Hyun Soo; Lee, Dong Ki; Kwon, Sang Ok

    2001-01-01

    To evaluate the cardiovascular and splanchnic hemodynamic changes in patients with liver cirrhosis and to compare with those of the normal controls using doppler ultrasonography. A total of 129 patients including 23 of Child-Pugh class A, 24 of class A, 24 of class B, 30 of class C, and 52 of the control group were included. Cardiac output (CO), systemic vascular resistance index (SVRI), and blood flow and pulsatility index (PI) of the superior mesenteric artery (SMA) were evaluated and compared among each groups. CO and SMA blood flow in the cirrhotic group were significantly higher than those in the control group, and the increase in CO and SMA blood flow showed a statistically significant correlation with the degree of liver dysfunction (p 2 =0.230). Hyperdynamic circulatory changes such as increases in CO and splanchnic blood flow were present in patients with liver cirrhosis. These changes may contribute to the development and maintenance of the portal hypertension due to an increase in portal blood flow an increase in portal blood flow.

  9. Relationship between renal hemodynamic status and aging in patients without diabetes evaluated by renal Doppler ultrasonography.

    Science.gov (United States)

    Kawai, Tatsuo; Kamide, Kei; Onishi, Miyuki; Hongyo, Kazuhiro; Yamamoto-Hanasaki, Hiroko; Oguro, Ryosuke; Maekawa, Yoshihiro; Yamamoto, Koichi; Takeya, Yasushi; Sugimoto, Ken; Ohishi, Mitsuru; Rakugi, Hiromi

    2012-10-01

    Aging is well known as one of the major causes of a reduced glomerular filtration rate (GFR). The resistive index (RI) measured by renal Doppler ultrasonography (RDU) is thought to be a good indicator of renal vascular resistance induced by arteriosclerosis. In this study, we investigated whether RI could be used to evaluate the pathogenesis of renal damage or the mechanisms of reduction of renal function by aging. We investigated the correlation between RI and multiple clinical parameters and the influence of aging on the renal hemodynamic status of 194 in-patients (mean age 66.2 years) who underwent RDU at our hospital between February 2009 and July 2010. RI was significantly correlated with the age, estimated GFR (eGFR), diastolic blood pressure, pulse pressure, and degree of albuminuria. Subjects aged ≥75 years showed a significantly higher correlation coefficient between eGFR and RI. RI showed a stronger correlation with age in subjects aged ≥75 years compared to eGFR. The present study showed that renal vascular resistance and intra-renal arteriosclerosis had a greater impact on renal function in older than younger subjects, reflecting the possible mechanisms of renal function reduction due to aging.

  10. Hyperdynamic circulatory changes in liver cirrhosis: Comparative evaluation by doppler ultrasonography with normal subjects

    Energy Technology Data Exchange (ETDEWEB)

    Im, Dae Wook; Baik, Soon Koo; Suh, Jung In; Kim, Jae Woo; Park, Yong Soon; Kim, Hyun Soo; Lee, Dong Ki; Kwon, Sang Ok [Yonsei University, Wonju College of Medicine, Wonju (Korea, Republic of)

    2001-12-15

    To evaluate the cardiovascular and splanchnic hemodynamic changes in patients with liver cirrhosis and to compare with those of the normal controls using doppler ultrasonography. A total of 129 patients including 23 of Child-Pugh class A, 24 of class A, 24 of class B, 30 of class C, and 52 of the control group were included. Cardiac output (CO), systemic vascular resistance index (SVRI), and blood flow and pulsatility index (PI) of the superior mesenteric artery (SMA) were evaluated and compared among each groups. CO and SMA blood flow in the cirrhotic group were significantly higher than those in the control group, and the increase in CO and SMA blood flow showed a statistically significant correlation with the degree of liver dysfunction (p<0.01). SVRI and SMA PI reflecting vascular resistance in the cirrhotic group were significantly lower than those in the control group, and the decrease in SVRI and SMA PI also showed a statistically significant correlation with the degree of liver dysfunction (p<0.01). SMA blood flow showed a statistically significant inverse relationship with SMA PI (R{sup 2}=0.230). Hyperdynamic circulatory changes such as increases in CO and splanchnic blood flow were present in patients with liver cirrhosis. These changes may contribute to the development and maintenance of the portal hypertension due to an increase in portal blood flow an increase in portal blood flow.

  11. [The diagnostic performance of color Doppler ultrasonography for newborn four cases of midgut volvulus accompanied by intestinal malrotation].

    Science.gov (United States)

    Ikeshima, Yukari; Hisano, Katsuya; Morisawa, Takeshi; Inoue, Kozue; Shimamoto, Masahiro; Koujitani, Toshiaki; Yonetani, Masahiko; Yasufuku, Masao

    2014-03-01

    Midgut volvulus accompanied by intestinal malrotation is classified as a surgical emergency disease of the newborn, which emerges with the bilious vomiting or melena. This report presents four patients of this disease in our hospital, evaluated by color Doppler ultrasonography before surgical operation. All four patients were presented by bilious vomiting at the onset. By color Doppler ultrasonography method, the whirlpool sign which is the view of intestine and superior mesenteric vein rotated around with the axis of superior mesenteric artery, were shown in all cases. This whirlpool sign led to the diagnosis of midgut volvulus accompanied by intestinal malrotation. Intestinal contrast imaging was tested in three patients for the purpose of confirming the diagnosis. Repair of the volvulus and a ladd operation was performed in all four patients, without the excision of intestine because of no intestinal ischemic change. The clinical courses of four cases were good, and all patients were discharged within 17 days. Early diagnosis and timely surgical operation are essential for decreasing the possibility of occurring intestinal ischemic changes and improving clinical outcome after surgical operation. We propose that color Doppler ultrasonography is the powerful tool for the diagnosis of this disease, especially for the newborn, for whom the available diagnostic tests are limited.

  12. Doppler ultrasonography combined with transient elastography improves the non-invasive assessment of fibrosis in patients with chronic liver diseases.

    Science.gov (United States)

    Alempijevic, Tamara; Zec, Simon; Nikolic, Vladimir; Veljkovic, Aleksandar; Stojanovic, Zoran; Matovic, Vera; Milosavljevic, Tomica

    2017-01-31

    Accurate clinical assessment of liver fibrosis is essential and the aim of our study was to compare and combine hemodynamic Doppler ultrasonography, liver stiffness by transient elastography, and non-invasive serum biomarkers with the degree of fibrosis confirmed by liver biopsy, and thereby to determine the value of combining non-invasive method in the prediction significant liver fibrosis. We included 102 patients with chronic liver disease of various etiology. Each patient was evaluated using Doppler ultrasonography measurements of the velocity and flow pattern at portal trunk, hepatic and splenic artery, serum fibrosis biomarkers, and transient elastography. These parameters were then input into a multilayer perceptron artificial neural network with two hidden layers, and used to create models for predicting significant fibrosis. According to METAVIR score, clinically significant fibrosis (≥F2) was detected in 57.8% of patients. A model based only on Doppler parameters (hepatic artery diameter, hepatic artery systolic and diastolic velocity, splenic artery systolic velocity and splenic artery Resistance Index), predicted significant liver fibrosis with a sensitivity and specificity of75.0% and 60.0%. The addition of unrelated non-invasive tests improved the diagnostic accuracy of Doppler examination. The best model for prediction of significant fibrosis was obtained by combining Doppler parameters, non-invasive markers (APRI, ASPRI, and FIB-4) and transient elastography, with a sensitivity and specificity of 88.9% and 100%. Doppler parameters alone predict the presence of ≥F2 fibrosis with fair accuracy. Better prediction rates are achieved by combining Doppler variables with non-invasive markers and liver stiffness by transient elastography.

  13. B-mode and Doppler ultrasonography of adrenal glands of healthy dogs

    Directory of Open Access Journals (Sweden)

    S. Fernandez

    2016-08-01

    Full Text Available ABSTRACT The aim of this study was to determine the vascular indices of adrenal blood flow in healthy dogs (systolic velocity - SV; diastolic velocity - DV; resistance index - RI. Eighteen dogs (thirty six adrenal were studied. Physical examination, biochemical profile and dexamethasone suppression test were performed to determine general health status. Echotexture, size, contours and margins, and overall shape of the adrenal gland (right and left were assessed via ultrasound. By spectral Doppler of the phrenic-abdominal artery, the SV, DV, and RI were acquired. Animals did not show alterations in clinical and laboratory examination and suppression of cortisol. Normal homogeneous and echotexture, regular contours and margins and normal shape and size were verified via B mode. Spectral Doppler of the phrenic-abdominal artery showed monophasic-patterned waves and low vascular resistance and systolic peak evident with means values: left adrenal - SV = 31.34cm/s, DV = 9.54cm/s and RI = 0.69; and right adrenal - SV = 27.83cm/s, DV = 7.71cm/s and RI = 0.68. Doppler evaluation of adrenal was easily implemented and may provide base line data in the study, allowing for the use of this technique as a diagnostic tool for diseases of the dog's adrenal.

  14. Mode B ultrasonography and abdominal Doppler in crab-eating-foxes ( Cerdocyon thous

    Directory of Open Access Journals (Sweden)

    Alanna S.L. Silva

    2014-12-01

    Full Text Available Abstract: Annually hundreds of crab-eating foxes (Cerdocyon thous are referred to rehabilitation centers and zoos in Brazil. The ultrasonographic study of wildlife species is an important tool for a non-invasive and accurate anatomical description and provides important information for wildlife veterinary care. The aim of the present study was to determine the characteristics of the main abdominal organs as well as the vascular indexes of the abdominal aorta and renal arteries of crab-eating foxes (Cerdocyon thous using mode B ultrasonography and Doppler ultrasonography, respectively. Ultrasonographic features of the main abdominal organs were described and slight differences were noticed between ultrasound imaging of abdominal organs of crab-eating foxes and other species. The bladder presented wall thickness of 12±0.01mm, with three defined layers. Both, the right and left kidneys presented corticomedullary ratio of 1:1 and similarly to the adrenals and the liver, they were homogeneous and hypoechoic compared to the spleen. The spleen was homogeneous and hyperechoic compared to the kidneys. The stomach presented 3 to 5 peristaltic movements per minute, wall thickness of 39±0.05mm and lumen and mucosa with hyperechoic and hypoechoic features, respectively. Small and large intestines presented 2 to 3 peristaltic movements per minute, wall thickness of 34±0.03mm and three defined layers with hyperechogenic (submucosa and serosa and hypoechogenic (muscular features. Ovaries of the female crab-eating fox were hypoechoic compared to the spleen and with heterogeneous parenchyma due to the presence of 2x2mm ovarian follicles. Prostates of the six males were regular and with a well defined boundary, with a homogeneous and hyperechoic parenchyma compared to the spleen. Vascular indexes of the abdominal aorta (PSV: 25.60±0.32cm/s; EDV: 6.96±1.68cm/s; PI: 1.15±0.07 e RI: 0.73±0.07 and right (PSV: 23.08±3.34cm/s; EDV: 9.33±2.36cm/s; PI: 1.01±0

  15. Doppler Ultrasonography in Suspected Subclavian Artery Obstruction and in Patient Monitoring after Subclavian Stenting

    International Nuclear Information System (INIS)

    Kablak-Ziembicka, Anna; Przewlocki, Tadeusz; Pieniazek, Piotr; Musialek, Piotr; Kozanecki, Artur; Stopa, Ireneusz; Zalewski, Jaroslaw; Tracz, Wieslawa

    2007-01-01

    Purpose. Subclavian or innominate artery (SIA) stenosis affects up to 5% of patients referred to coronary bypass grafting; it is symptomatic in less than half of these. This study aimed to assess the Doppler ultrasonography (DU) findings in SIA obstruction and patients' follow-up after percutaneous angioplasty (PTA). Methods. The study enrolled 118 patients (68 men, 50 women), aged 61.3 ± 8.7 years, with suspected SIA obstruction, in whom peak systolic velocity (PSV) in the SIA and subclavian steal grade were assessed on DU and verified by quantitative angiography (QA). Serial follow-up DU was performed in patients treated with PTA. Results. Grade I-III of subclavian steal from the vertebral artery (VA) was found in 89.8% of patients. In the remaining 10.2% only a PSV increase in the SIA was observed. QA confirmed the presence of SIA obstruction in all patients (stenosis grade: 80.9 ± 17.3%). In patients with one-sided SIA obstruction, the ultrasonographic steal grade correlated with the QA stenosis grade (p < 0.001, r = 0.648). Lack of subclavian steal was noted in the case of distal subclavian stenosis, VA obstruction, VA originating from the aortic arch, and bilateral SIA obstruction. Successful PTA was performed in 77 of 83 patients referred to that procedure. PSV was reduced from 4.4 ± 1.2 (2.2-6.5) m/sec to 1.34 ± 0.51 (0.5-2.5) m/sec and flow in the VA was normalized. During the mean follow-up time of 24.7 ± 15.6 months, there was a gradual increase in the in-stent PSV as well as gradual VA flow alterations, resulting in symptom recurrence. More than a twofold PSV increase, compared with the post-PTA values, was an indicator of restenosis in 11 of 12 patients. Conclusions. Careful DU evaluation enables the recognition of SIA obstruction in all patients. Ninety percent of them have subclavian steal correlating with the stenosis grade. Restenosis can be reliably detected with DU based on in-stent PSV and VA flow alterations

  16. Use of transesophageal Doppler ultrasonography in ventilated pediatric patients: derivation of cardiac output.

    Science.gov (United States)

    Tibby, S M; Hatherill, M; Murdoch, I A

    2000-06-01

    To ascertain if cardiac output (CO) could be derived from blood flow velocity measured in the descending aorta of ventilated children by transesophageal Doppler ultrasonography (TED) without the need for direct aortic cross sectional area measurement, and to evaluate the ability of TED to follow changes in CO when compared with femoral artery thermodilution. Prospective, comparison study. A 16-bed pediatric intensive care unit of a university hospital. A total of 100 ventilated infants and children aged 4 days to 18 yrs (median age, 27 months). Diagnoses included postcardiac surgery (n = 58), sepsis/multiple organ failure (n = 32), respiratory disease (n = 5), and other (n = 5). A total of 55 patients were receiving inotropes or vasodilators. When patients were hemodynamically stable, a TED probe was placed into the distal esophagus to obtain optimal signal, and minute distance (MD) was recorded. Five consecutive MD measurements were made concurrently with five femoral artery thermodilution measurements, and the concurrent measurements were averaged. CO was then manipulated by fluid administration or inotrope adjustment, and the readings were repeated. Femoral artery thermodilution CO ranged from 0.32 to 9.19 L/min, (median, 2.46 L/min), and encompassed a wide range of high and low flow states. Theoretical consideration revealed the optimal TED estimate for CO to be (MD x patient height2 x 10(-7)). Linear regression analysis yielded a power function model such that: estimated CO = 1.158 x (MD x height2 x 10(-7))(0.785), r2 = 0.879, standard error of the estimate = 0.266. Inclusion of a correction factor for potential changes in aortic cross-sectional area with hypo- and hypertension did not appreciably improve the predictive value of the model. MD was able to follow percentage changes in CO, giving a mean bias of 0.87% (95% confidence interval -0.85% to 2.59%), and limits of agreement of +/- 16.82%. The median coefficient of variation for MD was 3.3%. TED provides

  17. Doppler ultrasonography measurement of hepatic hemodynamics during Valsalva maneuver: healthy volunteer study

    Directory of Open Access Journals (Sweden)

    Dong-Ho Bang

    2015-01-01

    Full Text Available Purpose: The aim of our study was to assess the hemodynamic change of liver during the Valsalva maneuver using Doppler ultrasonography. Methods: Thirty healthy men volunteers were enrolled (mean age, 25.5±3.64 years. The diameter, minimal and maximal velocities, and volume flow of intrahepatic inferior vena cava (IVC, middle hepatic vein (MHV, and right main portal vein (RMPV was measured during both rest and Valsalva maneuver. These changes were compared using paired t-test. Results: The mean diameters (cm of the intrahepatic IVC at rest and Valsalva maneuver were 1.94±0.40 versus 0.56±0.66 (P<0.001. The mean diameter (cm, minimal velocity (cm/sec, maximal velocity (cm/sec, and volume flow (mL/min of MHV at rest and Valsalva maneuver were 0.60±0.15 versus 0.38±0.20 (P<0.001, -7.98±5.47 versus 25.74±13.13 (P<0.001, 21.34±6.89 versus 35.12±19.95 (P=0.002, and 106.94±97.65 versus 153.90±151.80 (P=0.014, respectively. Those of RMPV at rest and Valsalva maneuver were 0.78±0.21 versus 0.76±0.20 (P=0.485, 20.21±8.22 versus 18.73±7.43 (P=0.351, 26.79±8.85 versus 24.93±9.91 (P=0.275, and 391.52±265.63 versus 378.43±239.36 (P=0.315, respectively. Conclusion: The blood flow velocity and volume flow of MHV increased significantly during Valsalva maneuver. These findings suggest that hepatic vein might play an important role to maintain venous return to the heart during the maneuver.

  18. Doppler ultrasonography measuement of hepatic hemodynamics during Valsalva maneuver: healthy volunteers study

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Dong Ho; Son, Young Jin; Lee, Young Hwan; Yoon, Kwon Ha [Dept. of Radiology, Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2015-01-15

    The aim of our study was to assess the hemodynamic change of liver during the Valsalva maneuver using Doppler ultrasonography. Thirty healthy men volunteers were enrolled (mean age, 25.5±3.64 years). The diameter, minimal and maximal velocities, and volume flow of intrahepatic inferior vena cava (IVC), middle hepatic vein (MHV), and right main portal vein (RMPV) was measured during both rest and Valsalva maneuver. These changes were compared using paired t-test. The mean diameters (cm) of the intrahepatic IVC at rest and Valsalva maneuver were 1.94±0.40 versus 0.56±0.66 (P<0.001). The mean diameter (cm), minimal velocity (cm/sec), maximal velocity (cm/sec), and volume flow (mL/min) of MHV at rest and Valsalva maneuver were 0.60±0.15 versus 0.38±0.20 (P<0.001), -7.98±5.47 versus 25.74±13.13 (P<0.001), 21.34±6.89 versus 35.12±19.95 (P=0.002), and 106.94±97.65 versus 153.90±151.80 (P=0.014), respectively. Those of RMPV at rest and Valsalva maneuver were 0.78±0.21 versus 0.76±0.20 (P=0.485), 20.21±8.22 versus 18.73±7.43 (P=0.351), 26.79±8.85 versus 24.93±9.91 (P=0.275), and 391.52±265.63 versus 378.43±239.36 (P=0.315), respectively. The blood flow velocity and volume flow of MHV increased significantly during Valsalva maneuver. These findings suggest that hepatic vein might play an important role to maintain venous return to the heart during the maneuver.

  19. Absence of Doppler signal in transcranial color-coded ultrasonography may be confirmatory for brain death: A case report

    Directory of Open Access Journals (Sweden)

    Mehmet Akif Topçuoğlu

    2015-08-01

    Full Text Available Transcranial Doppler ultrasonography (TCD is a valuable tool for demonstrating cerebral circulatory arrest (CCA in the setting of brain death. Complete reversal of diastolic flow (to-and-fro flow and systolic spikes in bilateral terminal internal carotid arteries and vertebrobasilar circulation are considered as specific sonogram configurations supporting the diagnosis of CCA. Because of the possibility of sonic bone window impermeability, absence of any waveform in TCD is not confirmatory for CCA unless there is documentation of disappearance of a previously well detected signal by the same recording settings. Transcranial color-coded sonography (TCCS with B-mode imaging can reliably detect adequacy of bone windows with clarity contralateral skull and ipsilateral planum temporale visualization. Therefore, absence of detectable intracranial Doppler signal along with available ultrasound window in TCCS can confirm clinical diagnosis of brain death. We herein discuss this entity from the frame of a representative case.

  20. Ultrasonography for neuraxial blocks: a review of the evidence.

    Science.gov (United States)

    Elgueta, Maria F; Duong, Silvia; Finlayson, Roderick J; Tran, De Q

    2017-05-01

    This narrative review summarizes the evidence derived from randomized controlled trials (RCTs) pertaining to the use of adjunctive ultrasonography (US) for neuraxial blocks. The literature search was conducted using the MEDLINE, EMBASE and PUBMED databases. For the MEDLINE and EMBASE searches, the MESH terms "ultrasonography" and key word "ultrasound" were queried; using the operator "and", they were combined with the MESH terms "neuraxial block," "epidural anesthesia," "epidural analgesia," "spinal anesthesia," "spinal analgesia," "intrathecal anesthesia," "intrathecal analgesia," "caudal anesthesia," and "caudal analgesia." For the PUBMED search, the search terms "ultrasound neuraxial," "ultrasound intrathecal," "ultrasound epidural" (limited to clinical trials), "ultrasound spinal" (limited to clinical trials), and "ultrasound caudal" (limited to clinical trials) were queried. Seventeen RCTs were retained for analysis. Compared to conventional palpation of landmarks, US assistance (i.e., preprocedural scanning) results in fewer needle passes/insertions and skin punctures for neuraxial blocks in obstetrical and surgical patients. These benefits seem most pronounced when expert operators carry out the sonographic exams and for patients displaying difficult spinal anatomy. Preliminary findings also suggest that US provides similar pain relief and functional improvement to fluoroscopy for epidural/caudal steroid injection in patients afflicted with chronic spinal pain. Although one trial demonstrated shorter needling time with US guidance (i.e., real-time scanning of needle advancement) compared to US assistance, these findings require further validation. Published reports of RCTs provide evidence to formulate limited recommendations regarding the use of adjunctive US for neuraxial blocks. Further well-designed RCTs are warranted.

  1. Three-dimensional ultrasonography and power Doppler for discrimination between benign and malignant endometrium in premenopausal women with abnormal uterine bleeding.

    Science.gov (United States)

    El-Sharkawy, Mohamed; El-Mazny, Akmal; Ramadan, Wafaa; Hatem, Dina; Abdel-Hafiz, Aly; Hammam, Mohamed; Nada, Adel

    2016-03-16

    Ultrasonography has been extensively used in women suspected of having a gynecological malignancy. The aim of this study is to evaluate the efficacy of 3D ultrasonography and power Doppler for discrimination between benign and malignant endometrium in premenopausal women with abnormal uterine bleeding. This cross-sectional study included 78 premenopausal women with abnormal uterine bleeding scheduled for hysteroscopy and endometrial curettage. The endometrial thickness (ET), uterine artery pulsatility index (PI) and resistance index (RI), and endometrial volume (EV) and 3D power Doppler vascularization index (VI), flow index (FI), and vascularization flow index (VFI) were measured and compared with hysteroscopic and histopathologic findings. The ET (P benign and malignant endometrium was the VI with an area under the ROC curve of 0.88 at a cutoff value of 0.81%. 3D ultrasonography and power Doppler, especially endometrial VI, may be useful for discrimination between benign and malignant endometrium in premenopausal women with abnormal uterine bleeding.

  2. Determination of testicular blood flow in camelids using vascular casting and color pulsed-wave Doppler ultrasonography.

    Science.gov (United States)

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in fertile males compared to infertile males (P = 0.0004). In addition, end diastolic velocity (EDV) within the supratesticular arteries was higher for fertile males when compared to infertile males (P = 0.0325). Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P = 0.0104). However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P = 0.121). In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P = 0.486) and marginal arteries (P = 0.144). The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  3. [Practical Use of Doppler Ultrasonography of the Cardiovascular System and Clinical Laboratory Tests for the Management of Pulmonary Embolism].

    Science.gov (United States)

    Mizukami, Naoko

    2015-08-01

    Acute or chronic pulmonary embolism (PE) is a serious disease, and the risk of mortality is increased if untreated. In 90% of cases the embolus source is deep vein thrombosis (DVT) of the lower limbs or pelvic cavity. Therefore, it is necessary to recognize these as venous thromboembolism (VTE) which includes both DVT and PE. I suggest that Doppler ultrasonography of cardiovascular and clinical laboratory tests provide very valuable medical support for the management of VTE. Specifically, in the early diagnosis of VTE and the prevention of fatal PE, Doppler ultrasonography (cardiac and vascular) can provide very useful information. On the other hand, blood coagulation and thrombophilia tests are important to determine the risk of VTE and evaluate the effect of anticoagulant therapy on VTE. In this paper, I explain the main points of each examination of VTE by describing representative cases. I also show the results on investigating cases in our hospital involving diseases related to VTE and the onset site of DVT. In addition, I introduce how we convey the results of analysis to the clinical side.

  4. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    Directory of Open Access Journals (Sweden)

    Michelle Kutzler

    2011-01-01

    Full Text Available We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV was higher in fertile males compared to infertile males (P=0.0004. In addition, end diastolic velocity (EDV within the supratesticular arteries was higher for fertile males when compared to infertile males (P=0.0325. Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P=0.0104. However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P=0.121. In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P=0.486 and marginal arteries (P=0.144. The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  5. Discrimination between pleural thickening and minimal pleural effusion using color Doppler chest ultrasonography

    Directory of Open Access Journals (Sweden)

    Ali A. Hasan

    2013-07-01

    Conclusions: Application of color Doppler examination increases the accuracy of real time chest ultrasound to discriminate pleural thickening from minimal pleural effusion and hence color Doppler examination proved to be a useful diagnostic tool to real-time gray-scale ultrasound for diagnosis of minimal pleural effusion.

  6. Power Doppler Ultrasonography and Shear Wave Elastography as Complementary Imaging Methods for Suspected Local Breast Cancer Recurrence.

    Science.gov (United States)

    Jales, Rodrigo Menezes; Dória, Maira Teixeira; Serra, Kátia Piton; Miranda, Mila Meneguelli; Menossi, Carlos Alberto; Schumacher, Klaus; Sarian, Luis Otávio

    2018-06-01

    To prospectively investigate the diagnostic accuracy and clinical consequences of power Doppler morphologic criteria and shear wave elastography (SWE) as complementary imaging methods for evaluation of suspected local breast cancer recurrence in the ipsilateral breast or chest wall. Thirty-two breast masses with a suspicion of local breast cancer recurrence on B-mode ultrasonography underwent complementary power Doppler and SWE evaluations. Power Doppler morphologic criteria were classified as avascular, hypovascular, or hypervascular. Shear wave elastography was classified according to a 5-point scale (SWE score) and SWE maximum elasticity. Diagnostic accuracy was assessed by the sensitivity, specificity, and area under the curve. A decision curve analysis assessed clinical consequences of each method. The reference standard for diagnosis was defined as core needle or excisional biopsy. Histopathologic examinations revealed 9 (28.2%) benign and 23 (71.8%) malignant cases. Power Doppler ultrasonography (US) had sensitivity of 34.8% (95% confidence interval [CI], 6.6%-62.9%) and specificity of 45.4% (95% CI, 19.3%-71.5%). The SWE score (≥3) had sensitivity of 87.0% (95% CI, 66.4%-97.2%) and specificity of 44.4% (95% CI, 13.7%-78.8%). The SWE maximum elasticity (velocity > 6.5cm/s) had sensitivity of 87% (95% CI, 66.4%-97.2%) and specificity of 77.8% (95% CI, 40.0% to 97.2%). The areas under the curves for the SWE score and SWE maximum elasticity were 0.71 (95% CI, 0.53-0.87) and 0.82 (95% CI, 0.64-0.93), respectively (P = .32). Power Doppler US is unsuitable for discrimination between local breast cancer recurrence and fibrosis. Although the SWE score and SWE maximum elasticity can make this discrimination, the use of these methods to determine biopsy may lead to poorer clinical outcomes than the current practice of performing biopsies of all suspicious masses. © 2017 by the American Institute of Ultrasound in Medicine.

  7. [Diagnostic value of power Doppler ultrasonography for Sirenomelia Seguence in prenatal].

    Science.gov (United States)

    Yan, Xia-yu; Yang, Tai-zhu; Luo, Hong; Tian, Yu; Yang, Fan

    2011-11-01

    To study and discuss the diagnostic value and ultrasonographic characteristics of power doppler ultrasound in the prenatal diagnosis of Sirenomelia Seguence. The abdominal aorta in two fetuses with sirenomelia seguence fetuses and in ten with nomal was reviewed and compared with two-dimensional power doppler ultrasound and three-dimensional power doppler ultrasound in prenatal. The abdominal aorta were showed to divid into renal arteries in the kidney level while two common iliac arteries in the pelvis in nomal fetuses with two-dimensional power doppler ultrasound and three-dimensional power doppler ultrasound; compared with the nomal, the abdominal aorta and whose branches in sirenomelia seguence were demonstrated as follows: 1) a large and deformed vascular coming from the high abdominal aorta, which was found to act as a umbilical artery by careful examination; 2) no bifurcation of renal arteries identified; 3) no bifurcation of two common iliac arteries identified; 4) the abdominal aorta changing into a narrow vascular after one deformed vascular separating from. Sirenomelia seguence fetuses has a characteristic change in two-dimensional power doppler ultrasound and three-dimensional power doppler ultrasound, which is helpful to improve the prenatal diagnosis of sirenomelia seguence.

  8. Ultrasonography and color Doppler in juvenile idiopathic arthritis: diagnosis and follow-up of ultrasound-guided steroid injection in the ankle region. A descriptive interventional study

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2011-01-01

    The ankle region is frequently involved in juvenile idiopathic arthritis (JIA) but difficult to examine clinically due to its anatomical complexity. The aim of the study was to evaluate the role of ultrasonography (US) of the ankle and midfoot (ankle region) in JIA. Doppler-US detected synovial h...

  9. The predictive value of three-dimensional Doppler ultrasonography in determining implantation in patients underwent in vitro fertilization

    Directory of Open Access Journals (Sweden)

    Yusuf Çakmak

    2015-12-01

    Full Text Available Objective: The aim of this study is to evaluate the relationship between endometrial and sub-endometrial blood flow and implantation rate in patients whose undergone in vitro fertilization. Methods: A prospective study was conducted. Long protocol and antagonist regimens were administered to the patients. Endometrial and sub-endometrial blood flow was evaluated by using 3 dimensional Doppler ultrasonography on the day of oocyt retrieval measurement. For comparison pregnant and non-pregnant women in terms of endometrial and sub-endometrial blood flow, t test was used. The p value was considered statistically meaningful as 0.05. In long protocol group, the number of embryo was greater in pregnant women than non-pregnant women (p=0.012. The number of transferred embryo increased pregnancy rate almost 3.5 fold (p=0.002. Conclusion: The endometrial and subendometrial blood flow is not reliable factor in prediction pregnancy or implantation.

  10. Evaluation of the patients with renovascular hypertension after percutaneous revascularization by Doppler ultrasonography

    International Nuclear Information System (INIS)

    Akan, Huseyin; Arik, Nurol; Saglam, Seher; Danaci, Murat; Incesu, Lutfi; Selcuk, Mustafa Bekir

    2003-01-01

    Objective: Evaluation of the effectiveness of percutaneous revascularization is based primarily on clinical criteria, and laboratory findings rather than direct investigation of luminal width. The purpose of this study was to evaluate the success of endovascular revascularization with serial Doppler ultrasound (US) examinations. Methods and material: 19 patients (14 were atherosclerotic, five were with fibromuscular dysplasia) with suspected renovascular hypertension treated by percutaneous revascularization were included in a prospective study. Patients had 23 renal artery stenoses reducing the diameter by more than 50%. Doppler US examinations were performed before intervention, and 1 day, 3 and 6 months after intervention. Results: Initial revascularization was technically successful in 21 of 23 stenoses (91.3%) (18 PTRA, three stent placement). Hypertension was cured in five atherosclerotic and in five fibromuscular dysplasia (FMD) patients, and improved in four atherosclerotic patients. Residual stenosis was determined in six patients and the others were evaluated as normal by initial postprocedure Doppler US. As based on Doppler US, restenosis (>60%-narrowing) was depicted in four of six (66.6%) renal arteries with residual stenosis, and one of 15 (6.6%) normal renal arteries at 1 year. This difference in restenosis rates (residual stenosis vs. normal) was significant (P<0.05). Conclusion: Positive predictor for recurrence was a residual renal artery stenosis documented by Doppler US 1 day after percutaneous revascularization in atherosclerotic cases

  11. Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

    International Nuclear Information System (INIS)

    Lee, Myoung Seok; Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup; Park, Joong Shin; Jun, Jong Kwan

    2017-01-01

    The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and malalignment of the alveolus on the axial image, hard palate defects on the midsagittal image, and flow-through defects on CDUS taken during fetal breathing or swallowing were assessed. We compared the ultrasonography findings with postnatal findings in all fetuses. Alveolar defects were detected in 16 out of 17 cases with CP and four out of eight cases with CL. Alveolar malalignment and hard palate defects were detected in 11 out of 17 cases and 14 out of 17 cases with CP, respectively, but not detected in any cases with CL. Communicating flow through the palate defect was detected in 11 out of 17 cases of CL with CP. The accuracy of detection in axial scans of an alveolar defect and malalignment was 80% and 76%, respectively. Accuracy of detection of in mid-sagittal images of hard palate defect and flow was 80% and 86%, respectively. The overall diagnostic accuracy of combined axial and sagittal images with sagittal CDUS was 92%. Sagittal CDUS of the fetal hard palate is a feasible method to directly reveal hard palate bony defects and flow through defects, which may have additional value in the differential diagnosis of fetal CL and CP

  12. Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myoung Seok [Dept. of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Park, Joong Shin; Jun, Jong Kwan [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    2017-01-15

    The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and malalignment of the alveolus on the axial image, hard palate defects on the midsagittal image, and flow-through defects on CDUS taken during fetal breathing or swallowing were assessed. We compared the ultrasonography findings with postnatal findings in all fetuses. Alveolar defects were detected in 16 out of 17 cases with CP and four out of eight cases with CL. Alveolar malalignment and hard palate defects were detected in 11 out of 17 cases and 14 out of 17 cases with CP, respectively, but not detected in any cases with CL. Communicating flow through the palate defect was detected in 11 out of 17 cases of CL with CP. The accuracy of detection in axial scans of an alveolar defect and malalignment was 80% and 76%, respectively. Accuracy of detection of in mid-sagittal images of hard palate defect and flow was 80% and 86%, respectively. The overall diagnostic accuracy of combined axial and sagittal images with sagittal CDUS was 92%. Sagittal CDUS of the fetal hard palate is a feasible method to directly reveal hard palate bony defects and flow through defects, which may have additional value in the differential diagnosis of fetal CL and CP.

  13. A Comparative Study on Quantitative Assessment of Blood Flow and Vascularization in Polycystic Ovary Syndrome Patients and Normal Women Using Three-Dimensional Power Doppler Ultrasonography.

    Science.gov (United States)

    Garg, Nitasha; Khaira, Harkiran Kaur; Kaur, Manjot; Sinha, Smita

    2018-04-01

    To compare the quantitative assessment of blood flow and vascularization of ovaries in polycystic ovary syndrome patients and normal women using three-dimensional power Doppler ultrasonography. This cross-sectional quantitative study was conducted on women of reproductive age group (15-45 years) attending Gynaecology OPD AIMSR, Bathinda, Punjab. Thirty women were enrolled in polycystic ovarian syndrome (PCOS) group and 30 healthy women in control group. Women were categorized as polycystic ovary syndrome according to Rotterdam's criteria. The women with PCOS underwent transvaginal USG Doppler on day 6 of the cycle using 3D power Doppler USG equipment (GE Voluson E8), and vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were measured. The mean values of VI, FI and VFI measured by power Doppler ultrasonography were significantly increased ( P value = 0.000) in women with PCOS when compared with healthy women. This study suggests that blood flow and vascularization measured by 3D power Doppler ultrasonography in ovaries of polycystic ovary syndrome patients were significantly more than the ovaries of normal women.

  14. Serial 2-point ultrasonography plus D-Dimer vs whole-leg color-coded doppler ultrasonography for diagnosing suspected symptomatic deep vein thrombosis - A randomized controlled trial

    NARCIS (Netherlands)

    Bernardi, Enrico; Camporese, Giuseppe; Buller, Harry R.; Siragusa, Sergio; Imberti, Davide; Berchio, Arrigo; Ghirarduzzi, Angelo; Verlato, Fabio; Anastasio, Raffaela; Prati, Carolina; Piccioli, Andrea; Pesavento, Raffaele; Bova, Carlo; Maltempi, Patrizia; Zanatta, Nello; Cogo, Alberto; Cappelli, Roberto; Bucherini, Eugenio; Cuppini, Stefano; Noventa, Franco; Prandoni, Paolo

    2008-01-01

    Context Patients with suspected deep vein thrombosis ( DVT) of the lower extremities are usually investigated with ultrasonography either by the proximal veins ( 2-point ultrasonography) or the entire deep vein system ( whole- leg ultrasonography). The latter approach is thought to be better based

  15. Transabdominal color doppler ultrasonography: A relevant approach for assessment of effects of uterine torsion in buffaloes

    Directory of Open Access Journals (Sweden)

    Devender

    2016-08-01

    Full Text Available Aim: The present study was conducted on advanced pregnant buffaloes suffering from uterine torsion to assess the status of fetus and uterus by transabdominal ultrasonography, and the findings were compared with normal advanced pregnant buffaloes. Materials and Methods: The study was conducted on 20 clinical cases of uterine torsion and 20 normal advanced pregnant buffaloes (control group. The lower ventral area just lateral to linea alba (on both sides of the udder in standing animals was scanned transabdominally by the two-dimensional convex transducer for various ultrasonographic findings. The data collected were statistically analyzed by “one-way ANOVA” and “independent sample t-test” using computerized SPSS 16.0 software program. Results: Transabdominal ultrasonography revealed dead fetus in 95% uterine torsion cases and proved useful in imaging internal structures of fetuses while no dead fetus was reported in the control group. Size of umbilicus was found significantly decreased (p0.05 in uterine torsion group. Average thickness of the uterine wall and mean pixel values of fetal fluids (echogenicity were found significantly increased (p<0.05 in uterine torsion affected buffaloes in comparison to control group. Conclusion: Status of fetus (whether live or dead, internal status of uterus, and its contents could be determined by transabdominal ultrasonography in uterine torsion cases and thus determining the prognosis of the uterine torsion cases before going for further manipulations. This will also help in taking all the precautions to avoid death of the fetus.

  16. Evaluation of the thyroid blood flow with Doppler ultrasonography in healthy school-aged children

    International Nuclear Information System (INIS)

    Yazici, Burhan; Simsek, Enver; Erdogmus, Besir; Bahcebasi, Talat; Aktas, Alev; Buyukkaya, Ramazan; Uzun, Hakan; Safak, Alp Alper

    2007-01-01

    Objective: To determine the relationship between thyroid blood flow and anthropometric measurements, pubertal stage, and thyroid and gonadotropic hormones. Materials and methods: We examined 123 healthy school-aged children prospectively (69 boys (56.1%) and 54 girls (43.9%), 7-17 years old). Their sex, age, body weight, height, body mass index (BMI), and pubertal stage were determined. Serum thyrotropin, free thyroxine, luteinizing hormone, and follicle stimulating hormone were measured in both genders, along with testosterone in boys and estradiol in girls. The peak systolic velocity (PSV), resistance index (RI), and pulsatility index (PI) of the superior thyroid artery were determined. The correlations between the Doppler parameters and these factors were investigated. Results: There were no differences in age, weight, height, BMI, thyroid volume, PSV, RI, or PI between boys and girls (P > 0.05). The PSV and PI showed strong correlations with age, height, weight, puberty stage, thyroid volume, and BMI. The RI showed a strong inverse correlation with age, height, weight, puberty stage, and thyroid volume and a weak inverse correlation with the BMI. Conclusion: Determination of the thyroid arterial flow in normal healthy children is important during a Doppler ultrasound (US) examination. Doppler US parameters and their percentiles should be described in healthy children from different age groups, and these percentiles will aid in interpreting Doppler US in children

  17. Evaluation of the thyroid blood flow with Doppler ultrasonography in healthy school-aged children

    Energy Technology Data Exchange (ETDEWEB)

    Yazici, Burhan [Department of Radiology, Duzce University School of Medicine, Konuralp, Duzce 81620 (Turkey)], E-mail: dryazici@yahoo.com; Simsek, Enver [Department of Pediatrics, Duzce University School of Medicine, Konuralp, Duzce (Turkey); Erdogmus, Besir [Department of Radiology, Duzce University School of Medicine, Konuralp, Duzce 81620 (Turkey); Bahcebasi, Talat [Department of Public Health, Duzce University School of Medicine, Konuralp, Duzce (Turkey); Aktas, Alev [Department of Pediatrics, Duzce University School of Medicine, Konuralp, Duzce (Turkey); Buyukkaya, Ramazan [Department of Radiology, Duzce University School of Medicine, Konuralp, Duzce 81620 (Turkey); Uzun, Hakan [Department of Pediatrics, Duzce University School of Medicine, Konuralp, Duzce (Turkey); Safak, Alp Alper [Department of Radiology, Duzce University School of Medicine, Konuralp, Duzce 81620 (Turkey)

    2007-08-15

    Objective: To determine the relationship between thyroid blood flow and anthropometric measurements, pubertal stage, and thyroid and gonadotropic hormones. Materials and methods: We examined 123 healthy school-aged children prospectively (69 boys (56.1%) and 54 girls (43.9%), 7-17 years old). Their sex, age, body weight, height, body mass index (BMI), and pubertal stage were determined. Serum thyrotropin, free thyroxine, luteinizing hormone, and follicle stimulating hormone were measured in both genders, along with testosterone in boys and estradiol in girls. The peak systolic velocity (PSV), resistance index (RI), and pulsatility index (PI) of the superior thyroid artery were determined. The correlations between the Doppler parameters and these factors were investigated. Results: There were no differences in age, weight, height, BMI, thyroid volume, PSV, RI, or PI between boys and girls (P > 0.05). The PSV and PI showed strong correlations with age, height, weight, puberty stage, thyroid volume, and BMI. The RI showed a strong inverse correlation with age, height, weight, puberty stage, and thyroid volume and a weak inverse correlation with the BMI. Conclusion: Determination of the thyroid arterial flow in normal healthy children is important during a Doppler ultrasound (US) examination. Doppler US parameters and their percentiles should be described in healthy children from different age groups, and these percentiles will aid in interpreting Doppler US in children.

  18. Colour Doppler ultrasonography evaluation of vascularization in the wrist and finger joints in rheumatoid arthritis patients and healthy subjects

    Energy Technology Data Exchange (ETDEWEB)

    Carotti, M. [Department of Radiology, Poliytechnic University of Marche, Ancona (Italy); Salaffi, F., E-mail: fsalaff@tin.it [Department of Rheumatology, Poliytechnic University of Marche, Ospedale A. Murri - Via dei Colli 52, 60035 Jesi, Ancona (Italy); Morbiducci, J. [Department of Radiology, Poliytechnic University of Marche, Ancona (Italy); Ciapetti, A., E-mail: ciapetti.a@libero.it [Department of Rheumatology, Poliytechnic University of Marche, Ospedale A. Murri - Via dei Colli 52, 60035 Jesi, Ancona (Italy); Bartolucci, L. [Department of Radiology, Poliytechnic University of Marche, Ancona (Italy); Gasparini, S. [Department of Rheumatology, Poliytechnic University of Marche, Ospedale A. Murri - Via dei Colli 52, 60035 Jesi, Ancona (Italy); Ferraccioli, G. [Division of Rheumatology, Catholic University of the Sacred Heart, Rome (Italy); Giuseppetti, G.M. [Department of Radiology, Poliytechnic University of Marche, Ancona (Italy); Grassi, W. [Department of Rheumatology, Poliytechnic University of Marche, Ospedale A. Murri - Via dei Colli 52, 60035 Jesi, Ancona (Italy)

    2012-08-15

    Objectives: To evaluate the presence of blood flow by colour Doppler ultrasonography (CDUS) in the wrist and finger joints of rheumatoid arthritis (RA) patients and healthy subjects and to define a cut-off value of CDUS resistive index (RI). Methods: Forty-three patients with RA and 43 healthy controls were examined by CDUS. The wrists, second and third metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints were evaluated in each patient and healthy subject. Spectral Doppler analysis was performed in order to characterize the type of flow and a mean RI was measured to define a cut-off level. The area under receiver operating characteristic curve was used to evaluate the screening method's performance. Results: Flow was detected in 219 of the 430 total joints (50.9%) of RA patients (111 in the wrists, 49 in the MCP and 30 in the PIP joints). Healthy subjects had a quantifiable flow in 45 of the 430 joints (10.5%) and, in particular, 39 (86.4%) in the wrist, 5 (11.14%) in the MCP and 1 (2.2%) in the PIP joints. The intra- and inter-reader agreements for the detection of Doppler signal were very good (kappa 0.82 and 0.89, respectively). Mean RI values were 0.72 {+-} 0.06 in RA patients and 0.86 {+-} 0.06 in healthy subjects (p < 0.01). At cut-off point of RI < 0.79 the sensitivity was 89.6% and the specificity was 78.8% (positive likelihood ratio 4.22). Conclusion: DUS is a useful tool for the detection of abnormal blood flow in inflammatory joints of RA patients.

  19. Contrast-enhanced Harmonic power Doppler ultrasonography: Improved depiction of vascularity and characterization of flow pattern in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Baek, Hyung Chul; Yoon, Kwon Ha; Kim, Chang Guhn; Park, Ki Han; Won, Jong Jin

    2000-01-01

    To evaluate the value of contrast-enhanced harmonic power Doppler ultrasonography (PDUS) in depiction and characterization of tumoral vascularity in hepatocellular carcinoma (HCC). Thirty-three patients with HCC were prospectively evaluated with harmonic PDUS before and after injection of the contrast agent SH U 508A (2.5g, 300 mg/ml ). Unenhanced and serial dynamic scans at 15, 30, 45, 60, 90, 120, 150, 180, 240, 300 seconds after injection of contrast agents were obtained using a tissue harmonic technique with power Doppler imaging. The tumoral vascularity was expressed as percentage of power Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The grade (0, no signal; 1, less than 5%; 2, 5-25%; 3, more than 25%) and flow pattern (intratumoral, detour, basket, and mixed) of tumoral vascularity were analyzed. Peak time of contrast-enhancement was measured on each tumor. After injection of contrast agent, tumoral flow signals increased in all lesions (100%). At unenhanced harmonic PDUS, flow signals were detected in 17 HCCs (52%); 15 tumors (46%) demonstrated grade 1 vascularity; and two (6%), grade 2. At contrast-enhanced harmonic PDUS, all tumors were detected vascularity; five (15%) were grade 1; eight (24%), grade 2; and 20 (61%), grade 3. Flow patterns were demonstated as follows at unenhanced harmonic PDUS; intratumoral pattern in 13 tumors (76%), detour in 2 (12%), and basket in 2 (12%). After injection of contrast agent, intratumoral pattern in 7 tumors (21%), detour 0 (0%), basket in 3 (9%) and mixed in 23 (70%) were demonstrated. Peak time of enhancement after injection of contrast agent was 30- 90 seconds in majority of the patients. Contrast-enhanced harmonic PDUS would be valuable in depiction of vascularity and characterization of flow pattern in HCC.

  20. Contrast-enhanced Harmonic power Doppler ultrasonography: Improved depiction of vascularity and characterization of flow pattern in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Hyung Chul; Yoon, Kwon Ha; Kim, Chang Guhn; Park, Ki Han; Won, Jong Jin [Wonkwang University School of Medicine, Iksa (Korea, Republic of)

    2000-12-15

    To evaluate the value of contrast-enhanced harmonic power Doppler ultrasonography (PDUS) in depiction and characterization of tumoral vascularity in hepatocellular carcinoma (HCC). Thirty-three patients with HCC were prospectively evaluated with harmonic PDUS before and after injection of the contrast agent SH U 508A (2.5g, 300 mg/ml ). Unenhanced and serial dynamic scans at 15, 30, 45, 60, 90, 120, 150, 180, 240, 300 seconds after injection of contrast agents were obtained using a tissue harmonic technique with power Doppler imaging. The tumoral vascularity was expressed as percentage of power Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The grade (0, no signal; 1, less than 5%; 2, 5-25%; 3, more than 25%) and flow pattern (intratumoral, detour, basket, and mixed) of tumoral vascularity were analyzed. Peak time of contrast-enhancement was measured on each tumor. After injection of contrast agent, tumoral flow signals increased in all lesions (100%). At unenhanced harmonic PDUS, flow signals were detected in 17 HCCs (52%); 15 tumors (46%) demonstrated grade 1 vascularity; and two (6%), grade 2. At contrast-enhanced harmonic PDUS, all tumors were detected vascularity; five (15%) were grade 1; eight (24%), grade 2; and 20 (61%), grade 3. Flow patterns were demonstated as follows at unenhanced harmonic PDUS; intratumoral pattern in 13 tumors (76%), detour in 2 (12%), and basket in 2 (12%). After injection of contrast agent, intratumoral pattern in 7 tumors (21%), detour 0 (0%), basket in 3 (9%) and mixed in 23 (70%) were demonstrated. Peak time of enhancement after injection of contrast agent was 30- 90 seconds in majority of the patients. Contrast-enhanced harmonic PDUS would be valuable in depiction of vascularity and characterization of flow pattern in HCC.

  1. Discrimination between pleural thickening and minimal pleural effusion using color Doppler chest ultrasonography

    OpenAIRE

    Hasan, Ali A.; Makhlouf, Hoda A.; Mohamed, Alaa R.M.

    2013-01-01

    Background: The discrimination of pleural thickening from minimal pleural effusion may be difficult as both lesions appear as anechoic on grayscale ultrasound, hence, free of “echoes” does not confirm the presence of pleural fluid. Aim of this study: To evaluate the value of color Doppler ultrasound in differentiating minimal pleural effusion that could be aspirated from pleural thickening and to compare it with grayscale ultrasound. Patients and methods: This analytic cross-sectional s...

  2. Association of vitamin D insufficiency/deficiency with thyroid artery Doppler ultrasonography in patients with Hashimoto thyroiditis.

    Science.gov (United States)

    Nalbant, Ahmet; Aydin, Ayhan; Karacan, Alper; Onmez, Attila; Tamer, Ali; Cinemre, Hakan

    2017-01-01

    During the course of the autoimmune thyroid diseases, ultrasonography change parallel to histopathology. Vitamin D is associated with autoimmune diseases and thus can affect thyroid blood flow. Our aim was to investigate the relationship between vitamin D insufficiency/deficiency and thyroid hemodynamic indices in patients with Hashimoto thyroiditis. A total of 93 patients who presented to Sakarya University Endocrinology outpatient clinic from April to September 2016 and diagnosed with Hashimoto thyroiditis were included in this study. Clinical and serologic data, thyroid antibodies and 25(OH)D3 were evaluated. Mean peak systolic velocity(mPSV), mean end-diastolic velocity (EDV), mean resistive index (RI) flows of superior and inferior thyroid arteries were measured with B-mode Doppler ultrasonography. Vitamin D insufficiency/deficiency was detected in 59 (63.4%). TPO Ab and TgAb levels were found higher in patients with vitamin D insufficiency/deficiency. In the normal vitamin D group, superior thyroid artery mPSV (32.21±6.73cm/s) and EDV(13.27±2.80 cm/s) were higher than in the low vitamin D group [mPSV (28.32±8.99cm/s) and EDV(10.67±3.68 cm/s)] (P=0.034, P=0.001, respectively). Inferior thyroid artery EDV value was higher in the normal compared to the low vitamin D group (0.032). RI measured in all arteries were higher in the vitamin D insufficient/deficient group compared to the Vitamin D normal group (p=0.001). Vitamin-D insufficiency/deficiency has led to reduced parenchymal blood supply and increased micro-vascular resistance in Hashimoto thyroiditis patients.

  3. The use of the color Doppler ultrasonography in the diagnosis and monitoring of an atypical case of giant-cell arteritis.

    Science.gov (United States)

    Martins, N; Polido-Pereira, J; Rodrigues, A M; Soares, F; Batista, P; Pereira da Silva, J A

    2016-01-01

    Giant Cell Arteritis (GCA) is a large vessels vasculitis that is typically characterised by headache, scalp tenderness, jaw claudication and visual disturbances. Temporal arteries color Doppler ultrasonography (CDUS) is a sensitive and non-invasive image technique used in the diagnosis of this disease. This work highlights the importance of CDUS in the diagnostic workup of GCA and also demonstrates it´s usefullness in the evaluation and documentation of the response to corticosteroids therapy in an atypical case of ACG.

  4. Evaluation of hepatic venous pulsatility and portal venous velocity with doppler ultrasonography during the puerperium

    Energy Technology Data Exchange (ETDEWEB)

    Pekindil, Goekhan [Department of Radiology, Trakya University School of Medicine, 22030 Edirne (Turkey); Varol, Fuesun G. [Department of Obstetrics and Gynecology, Trakya University School of Medicine, 22030 Edirne (Turkey); Ali Yuece, M. [Department of Obstetrics and Gynecology, Trakya University School of Medicine, 22030 Edirne (Turkey); Yardim, Turgut [Department of Obstetrics and Gynecology, Trakya University School of Medicine, 22030 Edirne (Turkey)

    1999-03-01

    Objective: The aim of this study is to evaluate pregnancy-induced changes of hepatic venous pulsatility and portal venous velocity in the puerperium and to determine if these changes disappeared by the end of the puerperium. Methods and material: Healthy normal volunteers (90) were examined on the 2nd and 7th days of puerperium and between the 6th and 8th weeks postpartum. Doppler waveform patterns were obtained in the middle hepatic vein and main portal vein. The hepatic venous pulsatility was named as normal, damped or flat. Results: On the 2nd day postpartum, the hepatic vein pulsatility was shown as normal in 8 (26%), damped in 11 (37%) and flat in 11 (37%) cases. On the 7th day postpartum, 15 (50%) cases had normal, 9 (30%) cases had dampened, and 6 (20%) cases had still flat pattern. The majority of the cases (60%) displayed normal hepatic venous pulsatility in the 6th and 8th weeks of puerperium, whereas 23% had still dampened and 17% had flat patterns. There was a trend toward normal pulsatility with increasing puerperal age. The mean portal venous velocity was still higher than the non-pregnant levels and did not showed significant alterations during puerperium. Conclusion: This study emphasised that, since pregnancy-induced alterations in hepatic venous pulsatility and portal venous velocity had not completely returned to normal in most cases until the end of the puerperium, these physiological changes should be considered whenever hepatic and portal systems are interpreted with Doppler sonography during the puerperal period.

  5. Evaluation of hepatic venous pulsatility and portal venous velocity with doppler ultrasonography during the puerperium

    International Nuclear Information System (INIS)

    Pekindil, Goekhan; Varol, Fuesun G.; Ali Yuece, M.; Yardim, Turgut

    1999-01-01

    Objective: The aim of this study is to evaluate pregnancy-induced changes of hepatic venous pulsatility and portal venous velocity in the puerperium and to determine if these changes disappeared by the end of the puerperium. Methods and material: Healthy normal volunteers (90) were examined on the 2nd and 7th days of puerperium and between the 6th and 8th weeks postpartum. Doppler waveform patterns were obtained in the middle hepatic vein and main portal vein. The hepatic venous pulsatility was named as normal, damped or flat. Results: On the 2nd day postpartum, the hepatic vein pulsatility was shown as normal in 8 (26%), damped in 11 (37%) and flat in 11 (37%) cases. On the 7th day postpartum, 15 (50%) cases had normal, 9 (30%) cases had dampened, and 6 (20%) cases had still flat pattern. The majority of the cases (60%) displayed normal hepatic venous pulsatility in the 6th and 8th weeks of puerperium, whereas 23% had still dampened and 17% had flat patterns. There was a trend toward normal pulsatility with increasing puerperal age. The mean portal venous velocity was still higher than the non-pregnant levels and did not showed significant alterations during puerperium. Conclusion: This study emphasised that, since pregnancy-induced alterations in hepatic venous pulsatility and portal venous velocity had not completely returned to normal in most cases until the end of the puerperium, these physiological changes should be considered whenever hepatic and portal systems are interpreted with Doppler sonography during the puerperal period

  6. “Focal thyroid inferno” on color Doppler ultrasonography: A specific feature of focal Hashimoto's thyroiditis

    International Nuclear Information System (INIS)

    Fu, Xianshui; Guo, Limei; Zhang, Huabin; Ran, Weiqiang; Fu, Peng; Li, Zhiqiang; Chen, Wen; Jiang, Ling; Wang, Jinrui; Jia, Jianwen

    2012-01-01

    Purpose: To evaluate color-Doppler features predictive of focal Hashimoto's thyroiditis. Materials and methods: A total of 521 patients with 561 thyroid nodules that underwent surgeries or gun biopsies were included in this study. These nodules were divided into three groups: focal Hashimoto's thyroiditis (104 nodules in 101 patients), benignity other than focal Hashimoto's thyroiditis (73 nodules in 70 patients), and malignancy (358 nodules in 350 patients). On color Doppler sonography, four vascularity types were determined as: hypovascularity, marked internal flow, marked peripheral flow and focal thyroid inferno. The χ 2 test was performed to seek the potential vascularity type with the predictive ability of certain thyroid pathology. Furthermore, the gray-scale features of each nodule were also studied. Results: The vascularity type I (hypovascularity) was more often seen in focal Hashimoto's thyroiditis than other benignity and malignancy (46% vs. 20.5% and 19%). While the type II (marked internal flow) showed the opposite tendency (26.9% [focal Hashimoto's thyroiditis] vs. 45.2% [other benignity] and 52.8% [malignancy]). However, type III (marked peripheral flow) was unable to predict any thyroid pathology. Importantly, type IV (focal thyroid inferno) was exclusive to focal Hashimoto's thyroiditis. All 8 type IV nodules appeared to be solid, hypoechoic, and well-defined. Using “focal thyroid inferno” as an indicator of FHT, the diagnostic sensitivity and specificity were 7.7% and 100% respectively. Conclusions: The vascularity type of “focal thyroid inferno” is specific for focal Hashimoto thyroiditis. Recognition of this particular feature may avoid unnecessary interventional procedures for some solid hypoechoic thyroid nodules suspicious of malignancy.

  7. Reproducibility of task activation using the Addenbrooke's cognitive examination in healthy controls: A functional Transcranial Doppler ultrasonography study.

    Science.gov (United States)

    Beishon, L; Williams, C A L; Panerai, R B; Robinson, T G; Haunton, V J

    2017-11-01

    Cerebral blood flow velocity (CBFv) changes occurring with cognitive stimulation can be measured by Transcranial Doppler ultrasonography (TCD). The aim of this study was to assess the reproducibility of CBFv changes to the Addenbrooke's cognitive examination (ACE-III). 13 volunteers underwent bilateral TCD (middle cerebral artery), continuous heart rate (HR, 3-lead ECG, Finometer), beat-to-beat mean arterial pressure (MAP, Finometer), and end-tidal CO 2 (ETCO 2 , capnography). After 5min baseline, all ACE-III tasks were performed in 3 domains (A/B/C). Data presented are population CBFv peak normalised changes and area under the curve (AUC). Statistical analysis was by 2-way repeated measures (ANOVA), intra-class correlation coefficient (ICC), standard error of measurement (SEM) and coefficient of variation (CV). 12 bilateral data sets were obtained (10 right hand dominant, 6 female). Baseline parameters (MAP, HR, ETCO 2 ) did not differ between visits. All tasks increased CBFv. Only domain A on AUC analysis differed significantly on ANOVA, and one task on post hoc testing (p examine reproducibility of CBFv changes to a complete cognitive assessment tool. Reproducibility of CBFv measurements to the ACE-III was variable. AUC may provide more reliable estimates than peak CBFv responses. These data need validating in patient populations. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Role of Doppler ultrasonography evaluation of superior mesenteric artery flow volume in the assessment of Crohn's disease activity

    Directory of Open Access Journals (Sweden)

    Fabiana Paiva Martins

    2013-09-01

    Full Text Available Objective To investigate superior mesenteric artery flow measurement by Doppler ultrasonography as a means of characterizing inflammatory activity in Crohn's disease. Materials and Methods Forty patients were examined and divided into two groups – disease activity and remission – according to their Crohn's disease activity index score. Mean superior mesenteric artery flow volume was calculated for each group and correlated with Crohn's disease activity index score. Results The mean superior mesenteric artery flow volume was significantly greater in the patients with active disease (626 ml/min ± 236 × 376 ml/min ± 190; p = 0.001. As a cut off corresponding to 500 ml/min was utilized, the superior mesenteric artery flow volume demonstrated sensitivity of 83% and specificity of 82% for the diagnosis of Crohn's disease activity. Conclusion The present results suggest that patients with active Crohn's disease have increased superior mesenteric artery flow volume as compared with patients in remission. Superior mesenteric artery flow measurement had a good performance in the assessment of disease activity in this study sample.

  9. Renal transplant assessment with color and pulsed Doppler ultrasonography. 2nd part: inmunomedical complications

    International Nuclear Information System (INIS)

    Martin Hervas, C.; Gil de Miguel, A.

    1994-01-01

    We have performed 304 serial explorations in 140 renal transplant (Tx) recipients (42 recent and 98 past patients), assessing the morphological aspect of the graft (Size, surface, thickness and echogenicity of the parenchyma, corticomedullary index and renal sinus index), vascular permeability and the morphology of the arterial and venous waves, with calculation of the resistance indices (RI). We have compared these findings with those observed in a control group of 45 recipients with normally functioning grafts, comparing the different pathologies with respect to analytical, isotopic and histological findings. Doppler is a highly sensitive method for detecting processes that increase parenchymal resistance (rejection, acute tubular necrosis, cyclosporine toxicity, disease recurrence, infection, etc), but its specificity is poor. In past Tx recipients, chronic dysfunction or failure is the principal object of interest, while in the immediate postoperative period, it is important to compare the results of basal and follow-up studies. In acute tubular necrosis, the IR were not seen to deteriorate, in contrast to the findings in acute vascular rejection, and inversion of the diastolic pressures is a sign of poor prognosis. Despite the performance of other tests, biopsy is necessary in many cases to identify the etiology. (Author) 9 refs

  10. Functional evaluation of the urinary tract by color-Doppler ultrasonography (CDU) in 100 patients with renal colic

    Energy Technology Data Exchange (ETDEWEB)

    Pepe, Pietro E-mail: piepepe@hotmail.com; Motta, Luigi; Pennisi, Michele; Aragona, Francesco

    2005-01-01

    Introduction and objective: To evaluate if the addition of a renal color-Doppler ultrasonography (CDU) in the setting of acute renal colic improves the sensitivity of conventional sonography. Materials and methods: Between July 2002 and June 2003, 100 patients (median 49 years) with renal colic have been evaluated. Within 24 h of the admission, a CDU study of the urinary tract was performed using a sonograph GE Logiq 500 PRO with a multifrequency (3-5 MHz) convex probe. The following parameters were evaluated: ultrasonography (US) of both kidneys, ureters and bladder; resistive index (RI) of the arciform arteries of both kidneys in three different parenchymal areas; ureteric jets in response to hydration. A renal RI >0.70 and/or a 10% difference between the kidneys were considered as diagnostic of obstructive uropathy; an asymmetric and/or reduced ureteric jet from the ureteric orifices was an additional indicator of obstruction. All patients underwent a CT scan both with and without the administration of contrast medium. Results: Enhanced helical CT demonstrated an urinary stone in 90 out of the 100 patients (90%): 29 pyelic, 28 at the pyelo-ureteral junction, 23 lumbo-iliac and 10 juxtavesical stones. Among 90 patients with urolithiasis, the stone was undetectable with US in 11 cases (12.2%); in 8 cases (8.9%) pyelocalicectasis was absent, and in 6 patients (6.6%) a non-obstructive hydronephrosis was present. Median RI in obstructed and non-obstructed kidney was 0.73 (range 0.71-0.87) versus 0.62 (0.50-0.68), respectively; in two, obstructed kidneys RI was <0.70 but greater than 10% compared with normal side. Sensitivity and specificity of US, CDU (RI + ureteric jet), unenhanced helical CT and CDU in association with unenhanced helical CT were 94.8 and 55.5, 98.9 and 90.9, 100 and 100%, respectively. Discussion and conclusions: CDU in patients with renal colic and/or pelvicalicectasis improves the diagnostic accuracy of US in distinguishing between obstructive

  11. Soft-tissue tumor differentiation using 3D power Doppler ultrasonography with echo-contrast medium injection.

    Science.gov (United States)

    Chiou, Hong-Jen; Chou, Yi-Hong; Chen, Wei-Ming; Chen, Winby; Wang, Hsin-Kai; Chang, Cheng-Yen

    2010-12-01

    We aimed to evaluate the ability of 3-dimensional power Doppler ultrasonography to differentiate soft-tissue masses from blood flow and vascularization with contrast medium. Twenty-five patients (mean age, 44.1 years; range, 12-77 years) with a palpable mass were enrolled in this study. Volume data were acquired using linear and convex 3-dimensional probes and contrast medium injected manually by bolus. Data were stored and traced slice by slice for 12 slices. All patients were scanned by the same senior sonologist. The vascular index (VI), flow index (FI), and vascular-flow index (VFI) were automatically calculated after the tumor was completely traced. All tumors were later confirmed by pathology. The study included 8 benign (mean, 36.5 mL; range, 2.4-124 mL) and 17 malignant (mean, 319.4 mL; range, 9.9-1,179.6 mL) tumors. Before contrast medium injection, mean VI, FI and VFI were, respectively, 3.22, 32.26 and 1.07 in benign tumors, and 1.97, 29.33 and 0.67 in malignant tumors. After contrast medium injection, they were, respectively, 20.85, 37.33 and 8.52 in benign tumors, and 40.12, 41.21 and 17.77 in malignant tumors. The mean differences between with and without contrast injection for VI, FI and VFI were, respectively, 17.63, 5.07 and 7.45 in benign tumors, and 38.15, 11.88 and 16.55 in malignant tumors. Tumor volume, VI, FI and VFI were not significantly different between benign and malignant tumors before and after echo-contrast medium injection. However, VI, FI and VFI under self-differentiation (differences between with and without contrast injection) were significantly different between malignant and benign tumors. Three-dimensional power Doppler ultrasound is a valuable tool for differential diagnosis of soft-tissue tumors, especially with the injection of an echo-contrast medium. Copyright © 2010 Elsevier. Published by Elsevier B.V. All rights reserved.

  12. Quantitative Assessment of Synovial Vascularity Using Contrast-Enhanced Power Doppler Ultrasonography: Correlation with Histologic Findings and MR Imaging Findings in Arthritic Rabbit Knee Model

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Shin, Myung Jin; Kim, Seong Moon; Kim, Namkug; Suh, Sang Hyun; Suh, Jin Suck

    2008-01-01

    To validate contrast-enhanced power Doppler ultrasonography (PD US) for the evaluation of synovial vascularity in an arthritic rabbit knee model in correlation with MR and histological findings. Power Doppler ultrasonography was performed for carrageenin-induced arthritic left knee and control right knee of 13 rabbits, first without and then with sonic contrast agent enhancement (Levovist, Schering, Berlin Germany), followed by gadolinium-enhanced MR imaging. Synovial vascularity was quantitatively assessed by calculating the color pixel area in power Doppler sonography using a computer-aided image analysis program and by grading the enhancement on MR images: grade 1, enhancement of knee joint is less than one-third of the area; grade 2, one-third to two-thirds enhancement; and grade 3, more than two-thirds enhancement. Microvessel density (MVD) was measured on slides stained immunohistochemically for CD31 antigen for histological assessment. The mean area of color pixels in PD US changed from 4.37 to 16.42 mm 2 in the arthritic knee after enhancement (p 2 in the control knee (p 0.05). Sonic contrast-enhanced PD US improves the visualization of synovial vascularity and allows quantitative measurement in experimentally induced rabbit arthritic knees

  13. Fetal cardiac stroke volume determination by four-dimensional ultrasound with spatio-temporal image correlation compared with two-dimensional and Doppler ultrasonography.

    Science.gov (United States)

    Rizzo, Giuseppe; Capponi, Alessandra; Cavicchioni, Ottavia; Vendola, Marianne; Arduini, Domenico

    2007-12-01

    To assess the agreement of stroke volume (SV) measured with two-dimensional (2D) ultrasonography with Doppler capability (vs) four-dimensional (4D) with spatiotemporal image correlation (STIC) in normal and growth restricted fetuses. 2D Doppler and 4D STIC were used to measure SV of 40 normal fetuses at 20 to 22 and 28 to 32 weeks, and 16 growth-restricted fetuses at 26 to 34 weeks of gestation. Intraclass correlation was used to evaluate the agreement between left and right SV obtained by the two techniques, and proportionate Bland-Altman plots constructed. The time necessary to obtain SV was analyzed. The intraclass correlation coefficient between 2D Doppler and 4D STIC measurements for the left ventricle were 0.977 and 0.980 for the right ventricle. The proportionate limits of agreement between the two methods were 18.7 to 23.9% for the left ventricle and - 20.9 to 21.7% for the right ventricle. The time necessary to measure SV was significantly shorter with 4D STIC (3.1 (vs) 7.9 min p < 0.0001) than with 2D Doppler. There is a good agreement between SV measured either by 2D Doppler or by 4D STIC. The 4D STIC represents a simple and rapid technique to estimate fetal SV and promises to become the method of choice. Copyright (c) 2007 John Wiley & Sons, Ltd.

  14. Power Doppler ultrasonography for assessment of synovitis in the metacarpophalangeal joints of patients with rheumatoid arthritis: a comparison with dynamic magnetic resonance imaging

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Court-Payen, M; Strandberg, C

    2001-01-01

    OBJECTIVE: To evaluate the effectiveness of power Doppler ultrasonography (PDUS) for assessing inflammatory activity in the metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA), using dynamic magnetic resonance imaging (MRI) as a reference method. METHODS: PDUS and dynamic...... MRI were performed on 54 MCP joints of 15 patients with active RA and on 12 MCP joints of 3 healthy controls. PDUS was performed with a LOGIQ 500 unit by means of a 7-13-MHz linear array transducer. Later the same day, MRI was performed with a 1.0T MR unit. A series of 24 coronal T1-weighted images...

  15. The use of the color Doppler ultrasonography in the diagnosis and monitoring of an atypical case of giant-cell arteritis

    Directory of Open Access Journals (Sweden)

    Nádia Martins

    2016-04-01

    Full Text Available Giant Cell Arteritis (GCA is a large vessels vasculitis that is typically characterised by headache, scalp tenderness, jaw claudication and visual disturbances. Temporal arteries color Doppler ultrasonography (CDUS is a sensitive and non-invasive image technique used in the diagnosis of this disease. This work highlights the importance of CDUS in the diagnostic workup of GCA and also demonstrates it´s usefullness in the evaluation and documentation of the response to corticosteroids therapy in an atypical case of ACG.

  16. Identificação pelo eco-Doppler colorido de fístula arteriovenosa na trombose venosa profunda Arteriovenous fistula in deep venous thrombosis identified by color-flow Doppler ultrasonography

    Directory of Open Access Journals (Sweden)

    Fanilda Souto Barros

    2006-09-01

    Full Text Available Os três casos são referentes a pacientes em tratamento para trombose venosa profunda encaminhados ao laboratório vascular para avaliação da recanalização e/ou progressão do processo trombótico. Durante o estudo pelo eco-Doppler colorido, foram identificados sinais ecográficos compatíveis com fístula arteriovenosa no interior do trombo e adjacente à parede venosa.We report on a case series of three patients undergoing treatment for deep venous thrombosis, referred to our vascular laboratory for evaluation of recanalization and/or progression of the thrombotic process. During the color-flow Doppler ultrasonography, we identified ultrasound signs typical of arteriovenous fistula flow pattern within the thrombus and adjacent to the venous wall.

  17. Power Doppler ultrasonography and synovitis: correlating ultrasound imaging with histopathological findings and evaluating the performance of ultrasound equipments.

    Science.gov (United States)

    Koski, J M; Saarakkala, S; Helle, M; Hakulinen, U; Heikkinen, J O; Hermunen, H

    2006-12-01

    To examine the validity of power Doppler ultrasound imaging to identify synovitis, using histopathology as gold standard, and to assess the performance of ultrasound equipments. 44 synovial sites in small and large joints, bursae and tendon sheaths were depicted with ultrasound. A synovial biopsy was performed on the site depicted and a synovial sample was taken for histopathological evaluation. The performance of three ultrasound devices was tested using flow phantoms. A positive Doppler signal was detected in 29 of 35 (83%) of the patients with active histological inflammation. In eight additional samples, histological examination showed other pathological synovial findings and a Doppler signal was detected in five of them. No significant correlation was found between the amount of Doppler signal and histological synovitis score (r = 0.239, p = NS). The amount of subsynovial infiltration of polymorphonuclear leucocytes and surface fibrin correlated significantly with the amount of power Doppler signal: r = 0.397 (pultrasound devices differed in showing the smallest detectable flow. A negative Doppler signal does not exclude the possibility of synovitis. A positive Doppler signal in the synovium is an indicator of an active synovial inflammation in patients. A Doppler signal does not correlate with the extent of the inflammation and it can also be seen in other synovial reactions. It is important that the quality measurements of ultrasound devices are reported, because the results should be evaluated against the quality of the device used.

  18. Doppler ultrasonography of the anterior knee tendons in elite badminton players: colour fraction before and after match.

    Science.gov (United States)

    Koenig, M J; Torp-Pedersen, S; Boesen, M I; Holm, C C; Bliddal, H

    2010-02-01

    Anterior knee tendon problems are seldom reported in badminton players although the game is obviously stressful to the lower extremities. Painful anterior knee tendons are common among elite badminton players. The anterior knee tendons exhibit colour Doppler activity. This activity increases after a match. Painful tendons have more Doppler activity than tendons without pain. Cohort study. 72 elite badminton players were interviewed about training, pain and injuries. The participants were scanned with high-end ultrasound equipment. Colour Doppler was used to examine the tendons of 64 players before a match and 46 players after a match. Intratendinous colour Doppler flow was measured as colour fraction (CF). The tendon complex was divided into three loci: the quadriceps tendon, the proximal patellar tendon and the insertion on the tibial tuberosity. Interview: Of the 72 players, 62 players had problems with 86 tendons in the lower extremity. Of these 86 tendons, 48 were the anterior knee tendons. Ultrasound: At baseline, the majority of players (87%) had colour Doppler flow in at least one scanning position. After a match, the percentage of the knee complexes involved did not change. CF increased significantly in the dominant leg at the tibial tuberosity; single players had a significantly higher CF after a match at the tibial tuberosity and in the patellar tendon both before and after a match. Painful tendons had the highest colour Doppler activity. Most elite badminton players had pain in the anterior knee tendons and intratendinous Doppler activity both before and after match. High levels of Doppler activity were associated with self-reported ongoing pain.

  19. Colour doppler ultrasonography and sclerosing therapy in diagnosis and treatment of tendinopathy in horses-a research model for human medicine

    DEFF Research Database (Denmark)

    Boesen, Morten Ilum; Nanni, Simone; Langberg, Henning

    2007-01-01

    Sclerosing therapy has in recent studies showed promising results in patients with clinically and ultrasonographically diagnosed tendinosis in Achilles and patellar tendons. The aim of this investigation was to study the presence of intratendinous colour Doppler (CD) flow in horses with clinically...... diagnosed chronic tendinopathy and to test if experience from human studies could be extrapolated to horses. Special interest was focused on the treatment with sclerosing therapy and whether we could obtain the same successful peroperative findings as in humans. Four horses with clinically diagnosed...... unilateral chronic tendinosis in the forelimbs were examinated with both grey-scale ultrasonography (US) and CD. The horses were to be euthanised according to standard procedure is such cases. The US findings were used for guidance of sclerosing therapy. All horses showed abnormal findings on US, especially...

  20. Aplicação clínica da ultrassonografia craniana com Doppler em neonatos prematuros de muito baixo peso Clinical application of transcranial Doppler ultrasonography in premature, very-low-birth-weight neonates

    Directory of Open Access Journals (Sweden)

    Marta Lúcia Gabriel

    2010-08-01

    Full Text Available OBJETIVO: Analisar o valor do diagnóstico precoce de alterações hemodinâmicas em hemorragias e eventos hipóxico-isquêmicos pela avaliação de imagens e mensuração do índice de resistência por meio da ultrassonografia craniana com Doppler em neonatos prematuros de muito baixo peso. MATERIAIS E MÉTODOS: Cinquenta neonatos prematuros de muito baixo peso foram submetidos a ultrassonografia craniana com Doppler com a técnica transfontanela anterior e transtemporal sequenciais. RESULTADOS: Foram detectadas alterações cerebrais em 32% dos prematuros, sendo 22% com hemorragia intracraniana, 8% com leucomalácia periventricular e 2% com toxoplasmose. Dentre os 34 casos (68%, do total de neonatos, nos quais não foram detectadas lesões cerebrais pela ultrassonografia craniana, 18 (53% apresentaram alterações no índice de resistência. O índice de resistência variou conforme a época do exame. CONCLUSÃO: Existe correlação entre a presença de alterações na hemodinâmica cerebral e subsequente desenvolvimento de hemorragias e lesões hipóxico-isquêmicas, pela mensuração do índice de resistência. Alterações do índice de resistência, embora não preditoras de morte, estão relacionadas com a gravidade do quadro clínico em neonatos prematuros de muito baixo peso.OBJECTIVE: The present study was aimed at analyzing the value of the early diagnosis of hemodynamic changes in hemorrhages and hypoxic-ischemic events in premature, very-low-birth-weight neonates through the evaluation of images and resistance index measurement by means of transcranial Doppler ultrasonography. MATERIALS AND METHODS: Fifty premature, very-low-birth-weight neonates were submitted to transcranial Doppler ultrasonography with sequential transfontanellar and transtemporal techniques. RESULTS: Cerebral abnormalities were detected in 32% of the neonates (22% with intracranial hemorrhage, 8% with periventricular leukomalacia, and 2% with toxoplasmosis

  1. Experimentally induced acute uric acid nephropathy in rabbits: Findings of high resolution gray scale and doppler ultrasonographies

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ik; Chung, Soo Young; Lee, Kyung Won; Kim, Hong Dae; Ko, Eun Young; Won, Mi Sook; Noh, Jung Woo [Hallym University College of Medicine, Seoul (Korea, Republic of); Park, Moon Hyang [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2001-12-15

    To evaluate changes of the high-resolution (HR) gray scale and doppler ultrasonographic (US) characteristics of experimentally induced acute uric acid (UA) nephropathy in rabbits. Acute UA nephropathy was induced in ten rabbits using supersaturated lithium carbonate solution. The rabbits were divided in two groups. Group I consisted of five rabbits, and they were injected with a single dose of 150 ml of saturated UA over one hour. During tis period, serial US studies of the kidneys of these rabbits were performed every ten minutes. Group II consisted of the remaining five rabbits, and three injections of 50 ml of saturated UA solution were given on the first, fifth and eight day and follow-up was done upto twenty fifth day. Sequential HR and Doppler US, renal biopsy and blood sampling were performed on day 1, 5, 8, 21, and 25 in the group II rabbits. In group I, HR and Doppler US examination revealed the normal resistive index without significant abnormality. On the other hand, US studies of group II showed poor renal corticomedullary differentiation, decreased renal blood flow and elevated resistive index. There was statistically significant correlation among US findings, histologic characteristics and chemical index (BUN, creatinine) of renal function. In addition, sequentially increased size and volume of the kidney were noted in both groups. HR gray scale and doppler US characteristics of experimentally induced acute UA nephropathy in rabbits were similar to those of acute renal failure caused by other well-known causes.

  2. Experimentally induced acute uric acid nephropathy in rabbits: Findings of high resolution gray scale and doppler ultrasonographies

    International Nuclear Information System (INIS)

    Yang, Ik; Chung, Soo Young; Lee, Kyung Won; Kim, Hong Dae; Ko, Eun Young; Won, Mi Sook; Noh, Jung Woo; Park, Moon Hyang

    2001-01-01

    To evaluate changes of the high-resolution (HR) gray scale and doppler ultrasonographic (US) characteristics of experimentally induced acute uric acid (UA) nephropathy in rabbits. Acute UA nephropathy was induced in ten rabbits using supersaturated lithium carbonate solution. The rabbits were divided in two groups. Group I consisted of five rabbits, and they were injected with a single dose of 150 ml of saturated UA over one hour. During tis period, serial US studies of the kidneys of these rabbits were performed every ten minutes. Group II consisted of the remaining five rabbits, and three injections of 50 ml of saturated UA solution were given on the first, fifth and eight day and follow-up was done upto twenty fifth day. Sequential HR and Doppler US, renal biopsy and blood sampling were performed on day 1, 5, 8, 21, and 25 in the group II rabbits. In group I, HR and Doppler US examination revealed the normal resistive index without significant abnormality. On the other hand, US studies of group II showed poor renal corticomedullary differentiation, decreased renal blood flow and elevated resistive index. There was statistically significant correlation among US findings, histologic characteristics and chemical index (BUN, creatinine) of renal function. In addition, sequentially increased size and volume of the kidney were noted in both groups. HR gray scale and doppler US characteristics of experimentally induced acute UA nephropathy in rabbits were similar to those of acute renal failure caused by other well-known causes.

  3. Correlation of transcranial Doppler ultrasonography with MRI and MRA in the evaluation of sickle cell disease patients with prior stroke

    International Nuclear Information System (INIS)

    Kogutt, M.S.; Goldwag, S.S.; Gupta, K.L.; Kaneko, K.; Humbert, J.R.

    1994-01-01

    We prospectively evaluated a group of patients with sickle cell disease and a clinical history of prior stroke, comparing transcranial Doppler sonography (TCD) to both magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) to determine its efficacy for the detection of flow abnormalities associated with prior cerebral infarction. Using MRI as the standard examination, there was 94 % sensitivity and 30 % specificity, and using MRA as the standard examination, there was 91 % sensitivity and 22 % specificity. We concur with other reports that the transcranial Doppler examination is a highly sensitive study. In our group of sickle cell disease patients with prior stroke, TCD reliably detected flow abnormalities that correlated to areas of prior cerebral infarction. (orig.)

  4. Diagnostic value of color doppler ultrasonography in detecting stenosis and occlusion of central veins in patients with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Masoud Pezeshki Rad

    2015-01-01

    Full Text Available Venography is an invasive diagnostic test that uses contrast material that provides a picture of the condition of the veins. But, complications, including adverse effects on the kidney, do occur. On the other hand, with the current technological development, application of ultrasound in the diagnosis of obstructive diseases of the veins is gaining popularity, being non-invasive, easy to perform and cost-effective. The aim of this study was to evaluate the diagnostic value of Doppler sonography in the diagnosis of central vein stenosis. In this descriptive-analytical study, 41 hemodialysis patients who had been referred for 50 upper limb venographies to the radiology department of Imam Reza (AS were included. Patients with chronic kidney disease with a history of catheterization of the vein, jugular or subclavian, and who had established fistulas or synthetic vascular grafts were targeted. Central venous ultrasound was performed on both sides to evaluate stenosis or occlusion. Venography was performed by the radiologist the next day or the day before hemodialysis. Data on demographic characteristics, findings of clinical examination and findings of ultrasound as well as venography were recorded by using the SPSS software, Chi-square test and Spearman correlation, and Kappa agreement was calculated for sensitivity, specificity and predictive values. Twenty-three (56% patients were male subjects and 18 patients (44% were female. Twenty-three (56% patients of the study population were aged 60 years. The overall sensitivity, specificity and positive predictive value and negative predictive value of Doppler sonography in the proximal veins in hemodialysis patients compared with venography were, respectively, 80.9%, 79.3%, 73.9% and 85.1%. Color Doppler sonography, as a non-invasive method, could be a good alternative for venography in the assessment of the upper limb with central vein stenosis and occlusion.

  5. Diagnostic value of color doppler ultrasonography in detecting stenosis and occlusion of central veins in patients with chronic kidney disease.

    Science.gov (United States)

    Rad, Masoud Pezeshki; Kazemzadeh, Gholam Hosain; Ziaee, Masood; Azarkar, Ghodsieh

    2015-03-01

    Venography is an invasive diagnostic test that uses contrast material that provides a picture of the condition of the veins. But, complications, including adverse effects on the kidney, do occur. On the other hand, with the current technological development, application of ultrasound in the diagnosis of obstructive diseases of the veins is gaining popularity, being non-invasive, easy to perform and cost-effective. The aim of this study was to evaluate the diagnostic value of Doppler sonography in the diagnosis of central vein stenosis. In this descriptive-analytical study, 41 hemodialysis patients who had been referred for 50 upper limb venographies to the radiology department of Imam Reza (AS) were included. Patients with chronic kidney disease with a history of catheterization of the vein, jugular or subclavian, and who had established fistulas or synthetic vascular grafts were targeted. Central venous ultrasound was performed on both sides to evaluate stenosis or occlusion. Venography was performed by the radiologist the next day or the day before hemodialysis. Data on demographic characteristics, findings of clinical examination and findings of ultrasound as well as venography were recorded by using the SPSS software, Chi-square test and Spearman correlation, and Kappa agreement was calculated for sensitivity, specificity and predictive values. Twenty-three (56%) patients were male subjects and 18 patients (44%) were female. Twenty-three (56%) patients of the study population were aged 60 years. The overall sensitivity, specificity and positive predictive value and negative predictive value of Doppler sonography in the proximal veins in hemodialysis patients compared with venography were, respectively, 80.9%, 79.3%, 73.9% and 85.1%. Color Doppler sonography, as a non-invasive method, could be a good alternative for venography in the assessment of the upper limb with central vein stenosis and occlusion.

  6. Evaluation of the renal resistive index and pulsatility index in patients with pleural effusion by duplex Doppler ultrasonography.

    Science.gov (United States)

    Değirmenci, Nevbahar Akcar; Metintaş, Muzaffer; Atlanoglu, Sahinde; Yıldırım, Huseyin

    2013-01-01

    The aim of the study was to evaluate the renal resistive index (RI) and pulsatility index (PI) in patients with pleural effusion (PE). We studied the mean renal RI and PI in 50 patients with PE and 30 healthy volunteers by Doppler sonography. We grouped effusion as unilateral and bilateral. Statistical analysis was done by independent t test and correlation coefficient analysis. The mean RI/PI in healthy volunteers and in PE patients was 0.58/0.93 and 0.72/1.35, respectively. We observed a significantly higher RI and PI in patients when compared with healthy volunteers (all p effusion (0.74 or 1.55, respectively) (p > 0.05). Pleural effusion might result in increased renal impedance as seen in cirrhosis, which is a rather complicated pathophysiological process, without causing any morphological changes in kidneys.

  7. Evaluation of residual hepatocellular carcinoma after transcatheter arterial chemoembolization: Comparison between contrast-enhanced helical CT and contrast-enhanced power doppler ultrasonography

    International Nuclear Information System (INIS)

    Kim, Seung Hoon; Lim, Hyo Keun; Lee, Won Jae

    2001-01-01

    To evaluate the effectiveness of contrast-enhanced helical CT and contrast-enhanced power doppler ultrasonography (PDUS) in assessing the therapeutic effect of transcatheter arterial chemoembolization (TACE) in hepatocellular carcinomas (HCCs). The follow-up contrast-enhanced helical CT and contrast-enhanced PDUS were performed for twenty-nine nodular HCCs from twelve patients previously treated with TACE. We defined the residual HCCs as intratumoral enhancing area on contrast-enhanced helical CT and color signal on contrast-enhanced PDUS. The interval between two examinations was less than 2 weeks (mean, 9 days). Two radiologists evaluated two examinations by consensus, and the results of these two examination were compared with the findings of other examinations including CT, angiography, and/or pathology to calculate the sensitivity, specificity and accuracy of two examinations. Of the 29 HCCs, 20 had residual HCCs whereas no residual HCCs in 9 HCCs on pathologic examination and/or follow-up radiologic study. The sensitivity, sensitivity and accuracy of contrast-enhanced helical CT were 65 (13/20), 89 (8/9), and 72% (21/29) while those of contrast-enhanced PDUS were 100 (20/20), 89 (8/9) and 97% (28/29), respectively. A microbubble contrast-enhanced PDUS was more effective in the detection of residual tumor in HCCs following TACE than contrast-enhanced helical CT.

  8. Is there a relation between priapism occurring after penile doppler ultrasonography and international erectile function index score and erection hardness score levels?

    Science.gov (United States)

    Sönmez, Mehmet Giray; Öztürk, Ahmet

    2017-12-01

    The relation between Erection Hardness Score (EHS) and The International Erectile Function Index (IIEF) Questionnaire- Erectile Function Domain Score (IIEF-EF score) used in erectile dysfunction (ED) evaluation and the prevalence of priapism after penile Doppler ultrasonography (PDU) was examined in this study. A total of 62 patients who had PDU were included in the study. Patients were divided into two groups; there were 33 patients in IIEF-EF score ≤10, EHS 10, EHS ≥2 group (Group 2). The two groups separated according to their scores were compared for age, body mass index (BMI), prevalence of priapism, vascular comorbidities and duration of erection. When compared to Group 2, median age, rate of vascular comorbidities rate and BMI were detected to be higher in Group 1 with IIEF-EF score ≤10 and EHS 10 and EHS ≥2 (p<0.001, p=0.027, p=0.049 respectively). High IIEF-EF and EHS scores, younger ages and lower rates of vascular comorbidities in patients from whom PDU was demanded increase the prevalence of priapism.

  9. Limiting overdiagnosis of low-risk prostate cancer through an evaluation of the predictive value of transrectal and power Doppler ultrasonography.

    Science.gov (United States)

    Sauvain, Jean Luc; Sauvain, Elise; Papavero, Roger; Louis, Didier; Rohmer, Paul

    2016-12-01

    Overdiagnosis induced by prostate cancer screening makes necessary a better selection of candidate patients for prostate biopsy. The objective of our study is to assess the probability of having a high- or low-risk lesion that could require active surveillance (AS) after biopsies and a normal or abnormal examination, including transrectal and power Doppler ultrasonography (TRUS-PDS). Four hundred and twenty-nine consecutive patients with a PSA level risk of a biological recurrence and Dall'Era's criteria to assess possible AS. The TRUS-PDS was considered positive if one biopsy was positive in the same sextant as the suspect image. One hundred and seventy-seven out of 429 (41 %) T1c cancers were diagnosed; 131 out of 177 (74 %) could be qualified as low risk, and 119 out of 177 (67 %) could require AS. The TRUS-PDS was normal in 285 of 429 patients (66 %). With a normal TRUS-PDS, the probability of not having cancer with a high or intermediate risk was 96 % (negative predictive value). With an abnormal TRUS-PDS, the probability of having a positive biopsy was 59 %, and the probability of having a significant cancer was 30 %, according to the Dall'Era criteria. When TRUS-PDS was normal, these probabilities significantly decreased to 32 and 5 %, respectively ( p  risk of high- or intermediate-risk cancer.

  10. Transcranial Doppler ultrasonography in children with sickle cell anemia: Clinical and laboratory correlates for elevated blood flow velocities.

    Science.gov (United States)

    Lagunju, IkeOluwa; Sodeinde, Olugbemiro; Brown, Biobele; Akinbami, Felix; Adedokun, Babatunde

    2014-02-01

    Transcranial Doppler (TCD) sonography of major cerebral arteries is now recommended for routine screening for stroke risk in children with sickle cell disease (SCD). We performed TCD studies on children with sickle cell anemia (SCA) seen at the pediatric hematology clinic over a period of 2 years. TCD scans were repeated yearly in children with normal flow velocities and every 3 months in children with elevated velocities. Findings were correlated with clinical variables, hematologic indices, and arterial oxygen saturation. Predictors of elevated velocities were identified by multiple linear regressions. We enrolled 237 children and performed a total of 526 TCD examinations. Highest time-averaged maximum flow velocities were ≥170 cm/s in 72 (30.3%) cases and ≥200 cm/s in 20 (8.4%). Young age, low hematocrit, low hemoglobin, and arterial oxygen desaturation <95% showed significant correlations with presence of increased cerebral flow velocities. Low hematocrit, low hemoglobin concentration, young age, and low arterial oxygen desaturation predicted elevated cerebral blood flow velocities and, invariably, increased stroke risk, in children with SCA. Children who exhibit these features should be given high priority for TCD examination in the setting of limited resources. Copyright © 2013 Wiley Periodicals, Inc.

  11. The role of colour doppler ultrasonography of facial and occipital arteries in patients with giant cell arteritis: A prospective study.

    Science.gov (United States)

    Ješe, Rok; Rotar, Žiga; Tomšič, Matija; Hočevar, Alojzija

    2017-10-01

    Colour Doppler Sonography (CDS) in giant cell arteritis (GCA) allows the study of involvement of cranial arteries other than the temporal arteries, which are inconvenient to biopsy, such as the facial (FaA), and occipital (OcA) arteries. We aimed to estimate the frequency of the FaA, and OcA involvement in GCA; and to explore the clinical characteristics of these subgroups of patients. From 1 January 2014 to 31 December 2016 we prospectively performed a CDS of the FaA, and OcA in addition to the temporal (TA), and the extracranial supra-aortic arteries in all newly diagnosed patients suspected of having GCA. All the arteries were evaluated in two planes for the highly specific halo sign. During the 36-month observation period we performed a CDS of the cranial and extra-cranial arteries in 93 GCA patients. We observed the halo sign on the FaA, and OcA in 38 (40.9%), and 29 (31.2%) cases, respectively. The FaA, or OcA were affected in 4/22 (18.2%) patients with a negative TA CDS. FaA involvement significantly correlated with jaw claudication and with severe visual manifestations, including permanent visual loss. A fifth of patients with a negative CDS of the TAs had signs of vasculitis on the CDS of the FaA, or OcA. The addition of FaA and OcA CDS to the routine CDS of the TAs could identify 4.3% more patients and thus further improve the sensitivity of the CDS in the suspected GCA. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Transcranial Doppler ultrasonography in the assessment of neurovascular coupling responses to cognitive examination in healthy controls: A feasibility study.

    Science.gov (United States)

    Williams, C A L; Panerai, R B; Robinson, T G; Haunton, V J

    2017-06-01

    We tested the hypothesis that paradigms from the Addenbrooke's Cognitive Examination (ACE-III), including those that had not been studied using TCD previously (novel) versus those which had been (established), would elicit changes in CBF velocity (CBFv). Healthy subjects were studied with bilateral transcranial Doppler (TCD), beat-to-beat blood pressure (Finapres), continuous electrocardiogram (ECG), and end-tidal CO 2 (nasal capnography). After a 5-min baseline recording, cognitive tests of the ACE-III were presented to subjects, covering attention (SUB7, subtracting 7 from 100 sequentially), language (REP, repeating words and phrases), fluency (N-P, naming words), visuospatial (DRAW, clock-drawing), and memory (MEM, recalling name and address). An event marker noted question timing. Forty bilateral data sets were obtained (13 males, 37 right-hand dominant) with a median age of 31 years (IQR 22-52). Population normalized mean peak CBFv% in the dominant and non-dominant hemispheres, respectively, were: SUB7 (11.3±9.6%, 11.2±10.5%), N-P (12.7±11.7%, 11.5±12.0%), REP (12.9±11.7%, 11.6±11.6%), DRAW (13.3±11.7%, 13.2±15.4%) and MEM (13.2±10.3%, 12.0±10.1%). There was a significant difference between the dominant and non-dominant CBFv responses (pCognitive paradigms derived from the ACE-III led to significant lateralised changes in CBFv that were not distinct for novel paradigms. Further work is needed to assess the potential of paradigms to improve the interpretation of cognitive assessments in patients at risk of mild cognitive impairment. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. A comparison of radionuclide thyroid angiography, 99mTc-MIBI scintigraphy and power Doppler ultrasonography in the differential diagnosis of solitary cold thyroid nodules

    International Nuclear Information System (INIS)

    Demirel, Koray; Kapucu, Oezlem; Yuecel, Cem; Oezdemir, Hakan; Ayvaz, Goeksun; Taneri, Ferit

    2003-01-01

    We prospectively studied 43 patients with solitary cold thyroid nodules greater than 1.5 cm in diameter to determine the comparative diagnostic value of radionuclide thyroid angiography (RTA), technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) scintigraphy and power Doppler ultrasonography (PDUS) in the differentiation of benign and malignant thyroid nodules. Perfusion of the nodules in RTA was compared with the perfusion in the surrounding normal thyroid tissue and classified as follows: 0, avascular; 1, hypovascular; 2, isovascular; 3, hypervascular. 99m Tc-MIBI uptake in the nodules compared with that in surrounding thyroid tissue was scored for both early and delayed images as follows: 0, cold; 1, decreased; 2, equal; 3, increased. PDUS patterns were classified as nodule vascularisation patterns. The malignancy criteria were set as follows: hypervascular nodule with rapid washout in RTA; complex ring sign with anarchic structure or delta sign in PDUS, and positive retention and increased uptake in the nodule in the early and delayed 99m Tc-MIBI images. These data were compared with the histopathological results. Histology revealed thyroid carcinoma in nine patients (five cases of papillary carcinoma, three of follicular carcinoma and one of medullary carcinoma) and benign conditions in 34 patients (30 cases of nodular goitre, three of lymphocytic thyroiditis and one of follicular adenoma). Sensitivity, specificity and accuracy were, respectively, 0.89, 1.00 and 0.97 for RTA, 1.00, 0.76 and 0.81 for PDUS, and 0.67, 0.91 and 0.86 for 99m Tc-MIBI scintigraphy (when nodules with increased uptake in both the early and the delayed images and a positive retention index were considered as malignant). RTA, 99m Tc-MIBI scintigraphy and PDUS could be helpful in the preoperative assessment of solitary cold thyroid nodules. In this study, RTA was found to be the most accurate and specific method for differentiation of malignant from benign thyroid nodules. (orig.)

  14. Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study.

    Science.gov (United States)

    Zuhur, Sayid Shafi; Ozel, Alper; Velet, Selvinaz; Buğdacı, Mehmet Sait; Cil, Esra; Altuntas, Yüksel

    2012-01-01

    To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 age and sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. This study suggests that the measurement of inferior thyroid artery-blood flow velocities with color-flow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy.

  15. A comparison of radionuclide thyroid angiography, {sup 99m}Tc-MIBI scintigraphy and power Doppler ultrasonography in the differential diagnosis of solitary cold thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Demirel, Koray; Kapucu, Oezlem [Department of Nuclear Medicine, Gazi University School of Medicine, Ankara (Turkey); Yuecel, Cem; Oezdemir, Hakan [Department of Radiology, Gazi University School of Medicine, Ankara (Turkey); Ayvaz, Goeksun [Department of Endocrinology and Metabolic Diseases, Gazi University School of Medicine, Ankara (Turkey); Taneri, Ferit [Department of Surgery, Gazi University School of Medicine, Ankara (Turkey)

    2003-05-01

    We prospectively studied 43 patients with solitary cold thyroid nodules greater than 1.5 cm in diameter to determine the comparative diagnostic value of radionuclide thyroid angiography (RTA), technetium-99m methoxyisobutylisonitrile ({sup 99m}Tc-MIBI) scintigraphy and power Doppler ultrasonography (PDUS) in the differentiation of benign and malignant thyroid nodules. Perfusion of the nodules in RTA was compared with the perfusion in the surrounding normal thyroid tissue and classified as follows: 0, avascular; 1, hypovascular; 2, isovascular; 3, hypervascular. {sup 99m}Tc-MIBI uptake in the nodules compared with that in surrounding thyroid tissue was scored for both early and delayed images as follows: 0, cold; 1, decreased; 2, equal; 3, increased. PDUS patterns were classified as nodule vascularisation patterns. The malignancy criteria were set as follows: hypervascular nodule with rapid washout in RTA; complex ring sign with anarchic structure or delta sign in PDUS, and positive retention and increased uptake in the nodule in the early and delayed {sup 99m}Tc-MIBI images. These data were compared with the histopathological results. Histology revealed thyroid carcinoma in nine patients (five cases of papillary carcinoma, three of follicular carcinoma and one of medullary carcinoma) and benign conditions in 34 patients (30 cases of nodular goitre, three of lymphocytic thyroiditis and one of follicular adenoma). Sensitivity, specificity and accuracy were, respectively, 0.89, 1.00 and 0.97 for RTA, 1.00, 0.76 and 0.81 for PDUS, and 0.67, 0.91 and 0.86 for {sup 99m}Tc-MIBI scintigraphy (when nodules with increased uptake in both the early and the delayed images and a positive retention index were considered as malignant). RTA, {sup 99m}Tc-MIBI scintigraphy and PDUS could be helpful in the preoperative assessment of solitary cold thyroid nodules. In this study, RTA was found to be the most accurate and specific method for differentiation of malignant from benign

  16. The value of ultrasonography and Doppler sonography in prognosticating long-term outcomes among full-term newborns with perinatal asphyxia

    Directory of Open Access Journals (Sweden)

    Aušrelė Kudrevičienė

    2014-01-01

    Conclusions: Hypoxic-ischemic brain changes detected during ultrasonography and cerebral blood flow parameters associated with long-term outcomes of mental and neuromotor development at the age of 1-year.

  17. Influence of immune-mediated hemolytic anemia on flow velocities in the portal vein and caudal vena cava measured by use of pulsed-wave Doppler ultrasonography in dogs.

    Science.gov (United States)

    Smith, Rachel Policelli; Koenigshof, Amy M; Smith, Daniel J; Strom, Phillip R; Nelson, Nathan C

    2018-05-01

    OBJECTIVE To compare blood flow velocities of the portal vein (PV) and caudal vena cava (CVC) measured by use of pulsed-wave Doppler ultrasonography in clinically normal dogs and dogs with primary immune-mediated hemolytic anemia (IMHA). ANIMALS 11 client-owned dogs admitted to a veterinary teaching hospital for management of primary IMHA and 21 staff- or student-owned clinically normal dogs. PROCEDURES Flow velocities in the PV and CVC at the porta hepatis were evaluated in conscious unsedated dogs with concurrent ECG monitoring; evaluations were performed before dogs with IMHA received heparin or blood transfusions. Three measurements of peak velocity at end expiration were obtained for each vessel, and the mean was calculated. Results were compared between IMHA and control groups. RESULTS Mean ± SD blood flow velocity in the CVC differed between control (63.0 ± 18.6 cm/s) and IMHA (104 ± 36.9 cm/s) groups. Variance in dogs with IMHA was significantly greater than that for the clinically normal dogs. No significant difference in blood flow velocity in the PV was detected between IMHA and control dogs. CONCLUSIONS AND CLINICAL RELEVANCE Higher blood flow velocities were detected by use of pulsed-wave Doppler ultrasonography in the CVC of dogs with naturally occurring IMHA and may be used to predict anemia in patients suspected of having IMHA.

  18. [Doppler ultrasonography of the renal artery: Guidelines and predictive factors for the presence of a tight stenosis. Retrospective analysis of 450 consecutive examinations].

    Science.gov (United States)

    Dejerome, C; Grange, C; De Laforcade, L; Bonin, O; Laville, M; Lermusiaux, P; Long, A

    2018-05-01

    Duplex ultrasonography screening for renal artery stenosis has been the object of guidelines published by four societies designed to optimize the cost-effectiveness of the examination. To determine how well guideline indications for ultrasonography matched with requests and results in our university hospital; to determine whether compliance with guidelines was predictive of renal artery stenosis; to identify guidelines predictive of presence of stenosis; and to determine whether other predictive factors can be recognized. Requests and results of 450 Duplex ultrasonography examinations of the renal arteries performed from January 1st 2014 to December 31st 2015 were compared with published guidelines. At least one guideline indication was identified for 212 of the 450 examinations performed (47.1%). Among these examinations, renal artery stenosis≥70% was identified in 18 patients (8.0%). No case of stenosis was identified during examinations performed outside guideline indications. Factors predictive of stenosis were: compliance with guidelines (OR=21.86 [2.88; 165.8]). Predictive guidelines were: resistant hypertension in spite of appropriate treatment (OR=3.85, [1.44; 10.33], P=0.011), accelerated hypertension (OR=7.30, [1.40; 37.99], P=0.049), sudden unexplained pulmonary edema (OR=7.30, [1.40; 37.99], P=0.049), unexplained renal insufficiency (OR=3.58, [1.37; 9.37], P=0.011), unexplained renal hypotrophy (OR=16.69, [4.38; 63.69], P<0.001), renal asymmetry (OR=4.32, [1.45; 12.85], P<0.016). No other factor was predictive of renal stenosis. These examinations had therapeutic consequences in only 50% of patients. This study confirms the relevance of published guidelines. The diagnostic-effectiveness of Duplex ultrasonography examinations to search for renal artery stenosis depends upon compliance with these guidelines. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  19. Use of uterine artery Doppler ultrasonography to predict pre-eclampsia and intrauterine growth restriction: a systematic review and bivariable meta-analysis

    NARCIS (Netherlands)

    Cnossen, Jeltsje S.; Morris, Rachel K.; ter Riet, Gerben; Mol, Ben W. J.; van der Post, Joris A. M.; Coomarasamy, Arri; Zwinderman, Aeilko H.; Robson, Stephen C.; Bindels, Patrick J. E.; Kleijnen, Jos; Khan, Khalid S.

    2008-01-01

    BACKGROUND: Alterations in waveforms in the uterine artery are associated with the development of pre-eclampsia and intrauterine growth restriction. We investigated the predictive accuracy of all uterine artery Doppler indices for both conditions in the first and second trimesters. METHODS: We

  20. Power Doppler ultrasonography of painful Achilles tendons and entheses in patients with and without spondyloarthropathy-a comparison with clinical examination and contrast-enhanced MRI

    DEFF Research Database (Denmark)

    Wiell, Charlotte; Szkudlarek, Marcin; Hasselquist, Maria

    2013-01-01

    The objective of this study was to describe ultrasonography (US) and magnetic resonance imaging (MRI) findings at painful Achilles tendons and entheses in patients with and without spondyloarthropathy (SpA and non-SpA) and healthy control persons (CTRLs). Particularly, we aimed to investigate...... if any changes differentiate SpA from non-SpA. Finally, we investigated the reliability of US compared to clinical examination of Achilles tendinopathy, using MRI as gold standard reference. Twelve SpA patients and 15 non-SpA patients with pain and tenderness at at least one Achilles tendon and...

  1. Análisis de perforantes de la epigástrica inferior profunda con Angio TC 3D, Eco Doppler color y Doppler simple de ultrasonidos en colgajo DIEP: resultados preliminares Analysis of deep inferior epigastric perforating vessels with 3D CT angiography, color Doppler ultrasonography and Doppler in diep flaps: preliminary results

    Directory of Open Access Journals (Sweden)

    J. Castro García

    2008-09-01

    Full Text Available Nuestro objetivo es la validación de la Angio TC tridimensional como herramienta de planificación de los colgajos DIEP, comparándolo con el Doppler de ultrasonidos (US y eco Doppler color. Entre enero de 2006 y marzo de 2007 se realiza en 11 pacientes (13 DIEP un estudio comparativo prospectivo entre el Doppler de US, eco Doppler color y Angio TC con reconstrucción tridimensional, utilizando como dato de referencia los hallazgos intraoperatorios. En dicho proceso se localiza la mejor perforante que pueda servir como pedículo al colgajo DIEP en función de su localización, calibre, trayecto y relaciones anatómicas con respecto al músculo. La Angio TC con reconstrucción tridimensional, demuestra una especificidad del 100% (IC 95% 75.3-100 lo que le convierte en una prueba con un alto valor predictivo positivo y una excelente herramienta en la planificación de los colgajos de perforantes. El eco Doppler color determinó, que tan sólo en un 46,1% (IC 95% 19,2-74,9 de los pacientes, la perforante seleccionada por la prueba de forma preoperatoria, coincidía con la perforante elegida en quirófano. Con el Doppler de US, en un 30,8 % (IC 95% 9,1-61,4 de los colgajos estudiados, coincidía la mejor perforante escogida de forma preoperatoria, con los hallazgos obtenidos tras la disección del colgajo. En el presente estudio, la Angio TC tridimensional se ha mostrado como una técnica con una gran especificidad que proporciona valiosa información, sólo comparable con la disección anatómica y por delante de pruebas como el Doppler de ultrasonidos y el eco Doppler color.The aim of this report, is to validate the Angio-CT technique with three-dimentional reconstruction as a preoperative planning tool, after comparison with Doppler ultrasound and color- Duplex. Between january 2006 and march 2007, we studied 11 consecutive patients (13 DIEP in whom a prospective comparative followed up was performed comparing, the findings observed using

  2. 'Focal thyroid inferno' on color Doppler ultrasonography: A specific feature of focal Hashimoto's thyroiditis

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Xianshui, E-mail: fuxs1968@163.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Guo, Limei, E-mail: guolimei@bjmu.edu.cn [Department of Pathology, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Zhang, Huabin, E-mail: huabinzhang@bjmu.edu.cn [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Ran, Weiqiang, E-mail: ranwq-sina@vip.sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Fu, Peng, E-mail: fupeng01@gmail.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Li, Zhiqiang, E-mail: lizhq126@126.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Chen, Wen, E-mail: wendy7989@sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Jiang, Ling, E-mail: papayaling@yahoo.com.cn [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Wang, Jinrui, E-mail: jinrui_wang@sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Jia, Jianwen, E-mail: drjia88@sohu.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China)

    2012-11-15

    Purpose: To evaluate color-Doppler features predictive of focal Hashimoto's thyroiditis. Materials and methods: A total of 521 patients with 561 thyroid nodules that underwent surgeries or gun biopsies were included in this study. These nodules were divided into three groups: focal Hashimoto's thyroiditis (104 nodules in 101 patients), benignity other than focal Hashimoto's thyroiditis (73 nodules in 70 patients), and malignancy (358 nodules in 350 patients). On color Doppler sonography, four vascularity types were determined as: hypovascularity, marked internal flow, marked peripheral flow and focal thyroid inferno. The {chi}{sup 2} test was performed to seek the potential vascularity type with the predictive ability of certain thyroid pathology. Furthermore, the gray-scale features of each nodule were also studied. Results: The vascularity type I (hypovascularity) was more often seen in focal Hashimoto's thyroiditis than other benignity and malignancy (46% vs. 20.5% and 19%). While the type II (marked internal flow) showed the opposite tendency (26.9% [focal Hashimoto's thyroiditis] vs. 45.2% [other benignity] and 52.8% [malignancy]). However, type III (marked peripheral flow) was unable to predict any thyroid pathology. Importantly, type IV (focal thyroid inferno) was exclusive to focal Hashimoto's thyroiditis. All 8 type IV nodules appeared to be solid, hypoechoic, and well-defined. Using 'focal thyroid inferno' as an indicator of FHT, the diagnostic sensitivity and specificity were 7.7% and 100% respectively. Conclusions: The vascularity type of 'focal thyroid inferno' is specific for focal Hashimoto thyroiditis. Recognition of this particular feature may avoid unnecessary interventional procedures for some solid hypoechoic thyroid nodules suspicious of malignancy.

  3. Clinical utility of eco-color-power Doppler ultrasonography and contrast enhanced magnetic resonance imaging for interpretation and quantification of joint synovitis: a review.

    Science.gov (United States)

    Carotti, Marina; Galeazzi, Vittoria; Catucci, Francesca; Zappia, Marcello; Arrigoni, Francesco; Barile, Antonio; Giovagnoni, Andrea

    2018-01-19

    With the introduction of new biologics such as anti-TNF-alpha antibodies and other therapies in the treatment of inflammatory arthritis, capable of halting joint destruction and functional disability, there are new pressures on diagnostic and prognostic imaging. Early demonstration of pre-erosive inflammatory features and monitoring of the long-term effects of treatment are becoming increasingly important. Early detection of synovitis offers advantages in terms of allowing early instigation of therapy and may allow the identification of those patients displaying more aggressive disease who might benefit from early intervention with expensive DMARD therapy. Advanced imaging techniques such as ultrasound (US) and magnetic resonance imaging (MRI) have focussed on the demonstration and quantification of synovitis and allow early diagnosis of inflammatory arthropathies such as rheumatoid arthritis (RA) and psoriatic arthritis (PsA). Synovitis represents a potential surrogate measure of disease activity that can be monitored using either MRI or US; the techniques have, generally, focused on monitoring synovial volume or quality as assessed by its vascularity. However to achieve these goals, standardisation and validation of US and MRI are required to ensure accurate diagnosis, reproducibility and reliability. Each modality has different strengths and weaknesses and levels of validation. This article aims to increase the awareness of radiologists and rheumatologists about this field and to encourage them to participate and contribute to the ongoing development of these modalities. Without this collaboration, it is unlikely that these modalities will reach their full potential in the field of rheumatological imaging. This review is in two parts. The first part addresses the role of US and colour or power Doppler sonography (PDUS) in the detection and monitoring of synovitis in inflammatory arthropathies. The second part will look at advanced MR imaging and Dynamic contrast

  4. Surgeon-performed ultrasonography

    DEFF Research Database (Denmark)

    Todsen, Tobias

    2017-01-01

    Surgeons are increasingly using ultrasonography (US) in their clinical management of patients. However, US is a very user-dependent imaging modality and proper skills of the US operator are needed to ensure quality in patient care. This thesis explores the validity evidence for assessment...

  5. Ultrasonography of the canine pancreas

    Directory of Open Access Journals (Sweden)

    Michelle L Avante

    2018-01-01

    Full Text Available This study describes the ultrasonographic techniques currently used in the evaluation of the canine pancreas. Ultrasonography was the first method to enable direct visualization of the pancreas in humans and it has been subsequently applied to animals. Currently, it is the method of choice for pancreatic evaluation and is essential as a diagnostic tool in the detection of abnormalities, especially tumors. Innovative equipment technology has led to the emergence of techniques complementary to B-mode ultrasound; such as Doppler, elastography, and contrast-enhanced ultrasonography, which have enabled more accurate diagnosis. Doppler provides information on vascular architecture and the hemodynamic aspect of blood vessels in multiple organs. ARFI elastography provides detailed images of the alterations detected by conventional examination (qualitative method and assists in differentiating between benign and malignant processes (quantitative method. Microbubble contrast agents determine parameters related to homogeneous and heterogeneous filling of organs with microbubbles, mainly nodular areas, thus defining high and low intensity patterns.

  6. Prevalência do refluxo na veia safena parva em varizes primárias não complicadas dos membros inferiores pelo eco-Doppler colorido Prevalence of short saphenous vein reflux in primary uncomplicated varicose veins by Doppler ultrasonography

    Directory of Open Access Journals (Sweden)

    Fabio Secchi

    2006-03-01

    Full Text Available OBJETIVO: Determinar a prevalência de refluxo venoso na veia safena parva em membros inferiores com varizes primárias não complicadas pelo eco-Doppler colorido. MÉTODO: No período de 18 meses, 1.953 pacientes foram submetidos ao eco-Doppler colorido de membros inferiores por doença venosa. Destes, 1.631 com varizes primárias não complicadas foram selecionados para esta análise, sendo que 1.383 eram do sexo feminino (84,79% e 248 (15,21% do sexo masculino. A média de idade dos pacientes foi de 42,89 (± 0,48 anos, variando de 13 a 85 anos. Dos 1.631 pacientes, 1.323 foram submetidos a exame bilateral e 308 a exame unilateral, totalizando 2.954 membros inferiores com varizes primárias não complicadas avaliados. Desse total, 1.461 eram membros inferiores direitos e 1.493, esquerdos. Todos os exames foram realizados seguindo o mesmo protocolo. RESULTADO: Dos 2.954 membros inferiores avaliados, 372 (12,59% apresentaram refluxo em veia safena parva. A prevalência nos homens foi de 14,08% e, nas mulheres, de 12,35%. O refluxo da safena parva foi maior no membro inferior esquerdo (13.13% do que no direito (12,05%. A prevalência do refluxo foi significativamente maior nos pacientes acima de 60 anos. CONCLUSÃO: O refluxo da veia safena parva é relativamente comum, e sua pesquisa deve ser sempre realizada em pacientes com varizes primárias de membros inferiores.OBJECTIVE: To determine the prevalence of small saphenous vein reflux (SSVR in patients with uncomplicated varicose veins, using color-flow Doppler ultrasonography. METHOD: Over an 18-month period, a total of 1,953 patients underwent color-flow Doppler ultrasonography for evaluation of venous disease. Out of the total, 1,631 patients with primary uncomplicated varicose veins were selected for this study: 1,383 (84.79% patients were female and 248 (15.21% were male. Mean age was 42.9 (± 0.48 years, ranging from 13 to 85 years. Of the 1,631 patients, 1,323 underwent bilateral

  7. Relação entre índice de resistência obtido pela ultra-sonografia Doppler transfortanela e o neurodesenvolvimento até o primeiro ano de vida em recém-nascidos a termo com encefalopatia hipóxico-isquêmica leve e moderada Relation between the resistance index obtained by the transfontanellar Doppler ultrasonography and the neurological development until the first year of life in term infants with mild or moderate hypoxic-ischaemic encephalopathy

    Directory of Open Access Journals (Sweden)

    Maria Helena Martins Garcia

    2007-12-01

    Full Text Available OBJETIVO: Avaliar a relação do índice de resistência (IR obtido pela ultra-sonografia Doppler transfontanela com o neurodesenvolvimento até um ano de idade, em recém-nascidos (RN a termo com encefalopatia hipóxica-isquêmica (EHI leve a moderada, secundária à asfixia intra-parto. MÉTODO: Estudo prospectivo em 20 RN com EHI leve a moderada, IR elevado no primeiro exame de Doppler, e sem doenças associadas ou anormalidades morfológicas cerebrais. Foram realizados exames seriados bimensais de Doppler transfontanela a partir do sétimo dia de vida, e avaliações clínicas mensais do neurodesenvolvimento no primeiro ano de vida. RESULTADOS: Houve normalização progressiva dos valores de IR até o último exame realizado. Cinco pacientes apresentaram normalização clínico-neurológica no período neonatal, após o primeiro exame de Doppler. Quinze lactentes apresentaram alterações neurológicas com resolução a partir do segundo trimestre de vida. CONCLUSÃO: Houve relação entre os períodos em que ocorreu a normalização dos valores de IR e a melhora clínica-neurológica.OBJECTIVE: To evaluate the relation between the resistance index (RI obtained by transfontanellar Doppler ultrasonography, and the neurodevelopment until one year of life, at term newborns with mild or moderate hypoxic-ischaemic encephalopathy due to intrapartum asphyxia. METHOD: 20 term newborns, with mild or moderate hypoxic-ischemic encephalopathy, high values of resistance index in the first exam, and without cerebral morfologic abnormalities or other diseases. They were submitted to serial bimonthly transfontanellar Doppler ultrasonography, from the seventh day of life on, and monthly clinical neurodevelopment assessment until one year of life. RESULTS: There was a progressive normalization of RI values until the last examination. In five cases there were clinical neurologic normalization in the neonatal period after the first Doppler exam. Fifteen infants

  8. [Pancreatic ultrasonography].

    Science.gov (United States)

    Fernández-Rodríguez, T; Segura-Grau, A; Rodríguez-Lorenzo, A; Segura-Cabral, J M

    2015-04-01

    Despite the recent technological advances in imaging, abdominal ultrasonography continues to be the first diagnostic test indicated in patients with a suspicion of pancreatic disease, due to its safety, accessibility and low cost. It is an essential technique in the study of inflammatory processes, since it not only assesses changes in pancreatic parenchyma, but also gives an indication of the origin (bile or alcoholic). It is also essential in the detection and tracing of possible complications as well as being used as a guide in diagnostic and therapeutic punctures. It is also the first technique used in the study of pancreatic tumors, detecting them with a sensitivity of around 70% and a specificity of 90%. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  9. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncică, Ana Maria; Săftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...... cancers and visualization of the portal venous system and esophageal varices. In addition, contrast agents can be used to differentiate pancreatic lesions. The use of color Doppler further increases the ability to diagnose and differentiate various pancreatic malignancies. The sensitivity of power Doppler...

  10. Advances in diagnostic ultrasonography.

    Science.gov (United States)

    Reef, V B

    1991-08-01

    A wide variety of ultrasonographic equipment currently is available for use in equine practice, but no one machine is optimal for every type of imaging. Image quality is the most important factor in equipment selection once the needs of the practitioner are ascertained. The transducer frequencies available, transducer footprints, depth of field displayed, frame rate, gray scale, simultaneous electrocardiography, Doppler, and functions to modify the image are all important considerations. The ability to make measurements off of videocassette recorder playback and future upgradability should be evaluated. Linear array and sector technology are the backbone of equine ultrasonography today. Linear array technology is most useful for a high-volume broodmare practice, whereas sector technology is ideal for a more general equine practice. The curved or convex linear scanner has more applications than the standard linear array and is equipped with the linear array rectal probe, which provides the equine practitioner with a more versatile unit for equine ultrasonographic evaluations. The annular array and phased array systems have improved image quality, but each has its own limitations. The new sector scanners still provide the most versatile affordable equipment for equine general practice.

  11. Change of muscle architecture following body weight support treadmill training for persons after subacute stroke: evidence from ultrasonography.

    Science.gov (United States)

    Liu, Peng; Wang, Yanjun; Hu, Huijing; Mao, Yurong; Huang, Dongfeng; Li, Le

    2014-01-01

    Although the body weight support treadmill training (BWSTT) in rehabilitation therapy has been appreciated for a long time, the biomechanical effects of this training on muscular system remain unclear. Ultrasonography has been suggested to be a feasible method to measure muscle morphological changes after neurological diseases such as stroke, which may help to enhance the understanding of the mechanism underlying the impaired motor function. This study investigated the muscle architectural changes of tibialis anterior and medial gastrocnemius in patients after subacute stroke by ultrasound. As expected, we found the effect of BWSTT on the muscular system. Specifically, the results showed larger pennation angle and muscle thickness of tibialis anterior and longer fascicle length of medial gastrocnemius after the training. The findings of this study suggest that the early rehabilitation training of BWSTT in subacute stage of stroke provides positive changes of the muscle architecture, leading to the potential improvement of the force generation of the muscle. This may not only help us understand changes of subacute stroke in muscular system but also have clinical implications in the evaluation of rehabilitation training after neurological insults.

  12. Ultrasonography of the scrotum in adults

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Anna L.; Scotegagna, Eduardo; Nowitaki, Kristina M.; Kim, Young M. [Dept. of UMass Memorial Medical Center, University of Massachusetts Medical Center, Worcester (United States)

    2016-07-15

    Ultrasonography is the ideal noninvasive imaging modality for evaluation of scrotal abnormalities. It is capable of differentiating the most important etiologies of acute scrotal pain and swelling, including epididymitis and testicular torsion, and is the imaging modality of choice in acute scrotal trauma. In patients presenting with palpable abnormality or scrotal swelling, ultrasonography can detect, locate, and characterize both intratesticular and extratesticular masses and other abnormalities. A 12-17 MHz high frequency linear array transducer provides excellent anatomic detail of the testicles and surrounding structures. In addition, vascular perfusion can be easily assessed using color and spectral Doppler analysis. In most cases of scrotal disease, the combination of clinical history, physical examination, and information obtained with ultrasonography is sufficient for diagnostic decision-making. This review covers the normal scrotal anatomy as well as various testicular and scrotal lesions.

  13. Transabdominal Ultrasonography of the Small Bowel

    Directory of Open Access Journals (Sweden)

    Rudolf Kralik

    2013-01-01

    Full Text Available In the era of double balloon enteroscopy, capsule endoscopy, CT, and MRI enterography is transabdominal ultrasonography (TUS underestimated method for evaluation of small bowel pathology. As often initial imagine method in abdominal complaints, nowadays has TUS much better diagnostic potential than two decades ago. High-resolution ultrasound probes with harmonic imaging significantly improve resolution of bowel wall in real time, with possibility to asses bowel peristalsis. Color flow doppler enables evaluation of intramural bowel vascularisation, pulse wave doppler helps to quantificate flow in coeliac and superior mesenteric arteries. Small intestine contrast ultrasonography with oral contrast fluid, as well as contrast enhanced ultrasonography with intravenous microbubble contrast also improves small bowel imaging. We present a review of small intestine pathology that should be detected during ultrasound examinations, discuss technical requirements, advantages and limitations of TUS, typical ultrasound signs of Crohn's disease, ileus, celiac disease, intussusception, infectious enteritis, tumours, ischemic and haemorrhagic conditions of small bowel. In the hands of experienced investigator, despite some significant limitations(obesity, meteorism, is transabdominal ultrasonography reliable, noninvasive and inexpensive alternative method to computerised tomography (CT and magnetic resonance imaging (MRI in small bowel examination.

  14. Surgeon-performed ultrasonography.

    Science.gov (United States)

    Todsen, Tobias

    2017-11-01

    Surgeons are increasingly using ultrasonography (US) in their clinical management of patients. However, US is a very user-dependent imaging modality and proper skills of the US operator are needed to ensure quality in patient care. This thesis explores the validity evidence for assessment of competence in abdominal and head & neck ultrasonography using the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale. With the use of Messick's unitary framework of validity, five sources of validity evidence were explored: test content, response processes, inter-nal structure, relations to other variables, and consequences. Research paper I examined validity evidence for the use of the OSAUS scale to assess physicians' abdominal point-of-care US competence in an experimental setting using patient cases with and without pathological conditions. The RESULTS provided validity evidence of the internal structure of the OSAUS scale and a deci-sion study predicted that four cases and two raters or five cases and one rater could ensure sufficient reliability in future test setups. The relation to other variables was supported by a signifi-cant difference in scores between US experience levels, and by a strong correlation between the OSAUS score and diagnostic accuracy. Research paper II explored the transfer of learning from formal point-of-care US training to performance on patients in a randomized controlled study. The RESULTS supported validity evi-dence regarding OSAUS scores' relation to other variables by demonstrating a significant discrimination in the progress of training-a more refined validity evidence than the relation to difference experience levels. The RESULTS showed that physicians could transfer the skills learned on an ultrasonography course to improved US performance and diagnostic accuracy on patients. However, the RESULTS also indicated that following an initial course, additional training is needed for physicians to achieve competence in US

  15. Imaging in hematology. Part 1: Ultrasonography and conventional radiology

    International Nuclear Information System (INIS)

    Zhechev, Y.

    2003-01-01

    Applications of conventional ultrasonography techniques (B-mode or real time) in oncohematology are presented. The newer adaptations (in particular colour Doppler) provide incremental advantages that support their inclusion in the imaging techniques available to modern hematology. Conventional radiologic studies include chest and bone X-ray, gastrointestinal contrast examination and bipedal lymphangiography

  16. Ultrasonography versus intravenous urography

    International Nuclear Information System (INIS)

    Aslaksen, A.

    1991-01-01

    The present study was performed to compare the clinical value of urography and ultrasonography in a non-selected group of patients referred for urography to a university hospital. The conslusions and clinical implications of the study are as follows: Intravenous urography remains the cornerstone imaging examination in the evaluation of ureteral calculi. Ultrasonography is a valuable adjunct in cases of non- visualization of the kidneys, in distal obstruction and known contrast media allergy. When women with recurrent urinary tract infection are referred for imaging of the urinary tract, ultrasonography should be used. Ultrasonography should replace urography for screening of non-acute hydronephrosis like in female genital cancer and benign prostate hyperplasia. There is good correlation between urography and ultrasonography in assessing the degree of hydronephrosis. However, more researh on the relationship between hydronephrosis and obstruction is necessary. Ultrasonography should be used as the only imaging method of the upper urinary tract in patients with microscopic hematuria. In patients less than 50 years with macroscopic hematuria, ultrasonography should be used as the only imaging of the upper urinary tract, and an examination of the urinary bladder should be included. In patients over 50 years, urography supplied with ultrasonography should be used, but more research is necessary on the subject of imaging method and age. 158 refs

  17. The Place of Ultrasonography in the Evaluation of Rib Fractures

    OpenAIRE

    Fulya Bakılan; Gökhan Yüce; Ahmet Çağdaş Biçen; Tanju Keten

    2015-01-01

    Objective: The aim of this study was to investigate whether ultrasonography is superior to chest x-ray in detecting rib fractures in patients with minor blunt chest trauma and chest pain. Materials and Methods: Ultrasonography findings of 32 patients with minor blunt chest trauma showing no evidence of a rib fracture on anteroposterior chest x-rays, were documented. Presence of cortical discontinuities, acoustic shadows, reverberation artifacts, and hematoma by ultrasonography was...

  18. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  19. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  20. En bloc kidney transplantation: ultrasonography assessment

    International Nuclear Information System (INIS)

    Arenal, F.; Ganado, T.; Merino, M.S.; Contreras, E.; Hernandez, J.; Prats, D.

    1997-01-01

    The objective of our study is to assess the utility of ultrasonography in the study of the complications associated with en bloc kidney transplantation. Twenty-three recipients of double transplants from donors under the age of 3 years were studied. Ultrasound (mode B: pulsed Doppler and color Doppler) was performed within the first three postoperative days and was repeated at 6 and 12 months. The morphology of the graft and renal blood flow were assessed, and the indices of pulsatility, resistance and acceleration were measured. Four patients required graft explanation: three due to massive hemorrhagic infarction and one due to venous thrombosis. Vascular complications were detected in five transplants (21.7%), urological complications in four (17.4%) and medical complications in two (8.7%). The most common vascular complication was unilateral renal artery stenosis. Color Doppler ultrasound diagnosed all the medical and urological complications and three of the five cases of vascular pathology (60%). Renal size was seen to be increased during the first postoperative year. The ultrasonographic study is more difficult to perform in en bloc kidney transplantation than in single kidney grafting: however, given its marked sensitivity in the detection of postransplantation complications. Doppler ultrasound is the imaging technique of choice in the determination of the cause of deteriorated kidney function. (Author) 15 refs

  1. Role of Doppler US and MRI in diagnosis of placenta accreta

    Directory of Open Access Journals (Sweden)

    Manal Hamisa

    2015-09-01

    Conclusion: In conclusion, data of the present study show that the use of transabdominal color Doppler ultrasonography complemented by MRI in suspected cases improves the diagnostic accuracy in prediction of placenta accreta in patients with previous cesarean delivery.

  2. Power doppler ultrasound findings of renal infarct after experimental renal artery occlusion: comparison with spiral CT

    International Nuclear Information System (INIS)

    Jung, Seung Eun; Shinn, Kyung Sub; Kim, Hak Hee; Mun, Seok Hwan; Lee, Young Joon; Lee, Bae Young; Choi, Byung Gil; Lee, Jae Mun; Lee, Hee Jeong

    1999-01-01

    To evaluate the efficacy of power Doppler ultrasonography (PDUS) in depicting renal infarction in rabbits during experimental renal segmental arterial occlusion, and to compare the results with those of CT scanning. In 28 rabbits weighing 2.5 4kg, the segmental renal artery was occluded through the left main renal artery by embolization with Ivalon (Nycomed, Paris, France). Power Doppler ultrasonography and spiral CT scanning were performed before and at 2, 5, 8, 15, and 24 hours, and 3 and 7 days after occlusion of the segmental renal artery. The location of infarcted areas and collaterals, as seen on PDUS and CT scans, was evaluated by two radiologists. In all cases, as seen on power Doppler ultrasonography, infarcted areas-when compared with normal parenchyma, clearly demonstrated wedge-shaped perfusion defects in the kidney. The location of the lesion closely corresponded to the location seen during CT scanning. After renal arterial occlusion, transiently congested capsular arteries, which were named 'capsular sign', were seen in 63% of rabbits in the two and five-hour groups. No significant cortical rim sign was demonstrated on power Doppler ultrasonography, though it was noted on spiral CT at 15 and 24 hours, and 3 and 7 days after renal arterial occlusion. Power Doppler ultrasonography was useful for the diagnosis of renal infarction. Congested capsular artery seen in the early stage of renal infarction might be a characteristic finding of this condition, as seen on power Doppler ultrasonography

  3. Ultrasonography in trauma

    DEFF Research Database (Denmark)

    Weile, Jesper; Nielsen, Klaus; Primdahl, Stine C

    2017-01-01

    BACKGROUND: The Focused Assessment with Sonography in Trauma (FAST) protocol is considered beneficial in emergent evaluation of trauma patients with blunt or penetrating injury and has become integrated into the Advanced Trauma Life Support (ATLS) protocol. No guidelines exist as to the use...... of ultrasonography in trauma in Denmark. We aimed to determine the current use of ultrasonography for assessing trauma patients in Denmark. METHODS: We conducted a nation-wide cross-sectional investigation of ultrasonography usage in trauma care. The first phase consisted of an Internet-based investigation....... Twenty-one (95.5%) of the guidelines included and recommended FAST as part of trauma assessment. The recommended person to perform the examination was the radiologist in n = 11 (50.0%), the surgeon in n = 6 (27.3%), the anesthesiologist in n = 1 (4.5%), and unspecified in n = 3 (13.6%) facilities. FAST...

  4. Ultrasonography of polycystic kidney

    International Nuclear Information System (INIS)

    Oh, Seung Chul; Cho, Seung Gi; Lee, Kwan Seh; Kim, Kun Sang

    1980-01-01

    Polycystic disease is defined as a heritable disorder with diffuse involvement of both kidneys. The term 'Polycystic disease' comprises at least two separate, genetically different disease-one with an onset typically in childhood (infantile polycystic disease) and the other with an onset typically in adulthood (adult polycystic disease). Adult polycystic kidney disease is the most common form of cystic kidney disease in humans. Ultrasonography is a very useful noninvasive diagnostic modality in the patient with clinically suspected renal diseases as well as screening test. 14 cases of ultrasonography in patient with polycystic kidney were reviewed. All cases show unilateral or bilateral enlarged kidneys. 7 cases reveal kidneys and liver replaced by multiple cysts of varing size. Screening ultrasonography for a familial tree is reported

  5. Ultrasonography of jaundice

    International Nuclear Information System (INIS)

    Cho, Byung Jae; Bae, Sang Hoon; Lee, Seung Ro; Kim, Chu Wan

    1980-01-01

    The importance of ultrasonography in the evaluation of jaundice is stressed with an analysis of 47 cases of jaundice. 31 cases proved to be obstructive and 16 non-obstructive jaundice. Obstructive jaundice could be differentiated from non-obstructive jaundice in all but 2 cases, (96%). The site of obstruction in 31 cases of obstructive jaundice could be predicted correctly in 23 cases of 31, (90%), and cause of obstruction with an accuracy of 35% as well. One can certainly recommend ultrasonography as an initial procedure of choice in jaundice patients

  6. Ultrasonography in abdominal emergencies

    International Nuclear Information System (INIS)

    Risi, D.; Alessi, G.; Meli, C.; Marzano, M.; Fiori, E.; Caterino, S.

    1989-01-01

    From February 1986 to March 1988 113 abdominal US exams were performed in emergency situation to evaluate the accuracy of this methodology: 13 were blunt traumas, 18 post-operative complications. A real-time scanner with a linear probe of 5 MHz was employed. The results were confirmed by surgical and/or clinical and instrumental evaluation. In 81% of the examinations, ultrasonography allowed a diagnosis to be made. Gallbladder and biliary pathologies were the most common findings. The results (sensibility 96%, specificity 88%, accuracy 95%) confirm the affidability of ultrasonography in abdominal emergencies, as shown in literature

  7. A critical appraisal of the use of umbilical artery Doppler ultrasound in high-risk pregnancies: use of meta-analyses in evidence-based obstetrics

    DEFF Research Database (Denmark)

    Westergaard, H.B.; Langhoff-Roos, J.; Lingman, G.

    2001-01-01

    Doppler velocimetry; high-risk pregnancy; meta-analysis; intrauterine growth restriction; perinatal mortality; umbilical artery......Doppler velocimetry; high-risk pregnancy; meta-analysis; intrauterine growth restriction; perinatal mortality; umbilical artery...

  8. Sub-Doppler spectroscopy of thioformaldehyde: Excited state perturbations and evidence for rotation-induced vibrational mixing in the ground state

    International Nuclear Information System (INIS)

    Clouthier, D.J.; Huang, G.; Adam, A.G.; Merer, A.J.

    1994-01-01

    High-resolution intracavity dye laser spectroscopy has been used to obtain sub-Doppler spectra of transitions to 350 rotational levels in the 4 1 0 band of the A 1 A 2 --X 1 A 1 electronic transition of thioformaldehyde. Ground state combination differences from the sub-Doppler spectra, combined with microwave and infrared data, have been used to improve the ground state rotational and centrifugal distortion constants of H 2 CS. The upper state shows a remarkable number of perturbations. The largest of these are caused by nearby triplet levels, with matrix elements of 0.05--0.15 cm -1 . A particularly clear singlet--triplet avoided crossing in K a ' = 7 has been shown to be caused by interaction with the F 1 component of the 3 1 6 2 vibrational level of the a 3 A 2 state. At least 53% of the S 1 levels show evidence of very small perturbations by high rovibronic levels of the ground state. The number of such perturbations is small at low J, but increases rapidly beyond J=5 such that 40%--80% of the observed S 1 levels of any given J are perturbed by ground state levels. Model calculations show that the density and J dependence of the number of perturbed levels can be explained if there is extensive rotation-induced mixing of the vibrational levels in the ground state

  9. Ultrasonography X gamma radiography

    International Nuclear Information System (INIS)

    Mello Campos, A.M. de

    1989-01-01

    The accumulated experience in the last ten years of substitution to essays by gamma radiography to essay by ultrasonography, starting of the systematic comparison and tabulation of the results obtained by both essays applied in welding joints, in field, in steel pipelines of the SABESP. (V.R.B.)

  10. Ultrasonography of the Kidney

    DEFF Research Database (Denmark)

    Lindskov Hansen, Kristoffer; Nielsen, Michael Bachmann; Ewertsen, Caroline

    2016-01-01

    Ultrasonography of the kidneys is essential in the diagnosis and management of kidney-related diseases. The kidneys are easily examined, and most pathological changes in the kidneys are distinguishable with ultrasound. In this pictorial review, the most common findings in renal ultrasound...

  11. The use ofDoppler velocitnetry ofthe utnbilical artery before 24 ...

    African Journals Online (AJOL)

    growth retardation with umbilical artery Doppler ultrasonography. BM] 1989; 298: 631-635. 12. Schulman H, Winter D, Farmakides G, er al. Pregnancy surveil- lance with Doppler velocimerry of the uterine and umbilical arter- ies. Am] Obstet Gyneco11989; 160: 192-196. 13. Hanrerry KP, Primrose MH, Neilson JP, Whittle MJ.

  12. The Place of Ultrasonography in the Evaluation of Rib Fractures

    Directory of Open Access Journals (Sweden)

    Fulya Bakılan

    2015-12-01

    Full Text Available Objective: The aim of this study was to investigate whether ultrasonography is superior to chest x-ray in detecting rib fractures in patients with minor blunt chest trauma and chest pain. Materials and Methods: Ultrasonography findings of 32 patients with minor blunt chest trauma showing no evidence of a rib fracture on anteroposterior chest x-rays, were documented. Presence of cortical discontinuities, acoustic shadows, reverberation artifacts, and hematoma by ultrasonography was proposed as the diagnostic criteria for detecting the rib fracture. Results: Rib fracture was detected in 20 patients (62.5% according to ultrasonography results. A mildly displaced fracture was detected in 7 patients (35%, hematoma was detected in 3 patients (15% and multiple fractures (in 5th, 6th, 7th, and 8th ribs were detected in 1 patient (5%. Conclusion: The results of our study showed that ultrasonography is superior to chest x-ray, in detecting rib fractures.

  13. Cognitive dysfunction in congestive heart failure: transcranial Doppler evidence of microembolic etiology Disfunção cognitiva na insuficiência cardíaca congestiva: evidência de etiologia microembólica ao Doppler transcraniano

    Directory of Open Access Journals (Sweden)

    Pedro A.P. Jesus

    2006-06-01

    Full Text Available Cognitive symptoms are common in patients with congestive heart failure (CHF and are usually attributed to low cerebral blood flow. In the present study, we aimed to evaluate global cognitive function (Mini Mental State Exam MMSE in relation to both cardiac function (evaluated by echocardiogram and cerebrovascular hemodynamics (evaluated by transcranial Doppler TCD in CHF patients. In 83 patients studied, no correlation was found between echocardiographic parameters and MMSE scores. In contrast, a significant correlation was found between right middle cerebral artery (RMCA mean flow velocity and MMSE score (r=0.231 p=0.039, as well as between RMCA pulsatility index and MMSE score (r s= -0.292 p=0.015. After excluding patients with a previous history of stroke, only RMCA pulsatility index correlated with MMSE score (r s=-0,314 p=0,007. The relationship between high cerebrovascular resistance and worse cognitive scores suggest that microembolism may be responsible for a significant proportion of cognitive symptoms in CHF patients.Sintomas cognitivos são comuns em pacientes com insuficiência cardíaca congestiva (ICC e são geralmente atribuídos a um regime de baixo fluxo sanguíneo cerebral. Neste estudo, objetivamos avaliar a função cognitiva global (Mini Exame do Estado Mental MEEM em pacientes com ICC e sua relação com o grau de disfunção cardíaca (avaliada pelo ecocardiograma e a hemodinâmica cerebral (avaliada pelo Doppler transcraniano DTC. Em 83 pacientes estudados, nenhuma correlação foi encontrada entre a pontuação no MEEM e parâmetros ecocardiográficos. Em contraste, uma correlação significativa foi encontrada entre a velocidade média na artéria cerebral média direita (ACMD e a pontuação no MEEM (r=0,231 p=0,039, assim como entre o índice de pulsatilidade na ACMD e a pontuação no MEEM (r s=-0,292 p=0,015. Após excluir pacientes com histórico prévio de acidente vascular encefálico, somente o índice de

  14. Ultrasonography in Obstertrics

    International Nuclear Information System (INIS)

    Lee, Hyon U.

    1982-01-01

    The usefulness of pulse-echo ultrasonography of the practices of obstetrics has been great. It is more reliable than many biochemical and biophysical technics that have been developed in recent years to try to improve pregnancy outcome. When carefully performed and accurately interpreted, it can supply most vital information about the status of the fetus without any known risks to both mother and the fetus itself. The main obstertricalindications of ultrasonography coule be summarized as follows. 1. Diagnosis of early pregnancy. 2. Fetal growth and its maturity. 3. Complications of pregnancy and abnormal pregnancy. a) Vaginal bleeding in early intrauterinepregnancy. b) Multiple pregnancy. c) Ectopic pregnancy d) Hydatidiform mole e) Pelvic mass complicated with pregnancy f) Fetal anomaly 4. Fetal presenation and attitude 5. Placentography

  15. Color Doppler Ultrasonographic Findings of Vascular Leiomyoma: Pathologic Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Ji Young; Koh, Sung Hye; Min, Soo Kee; Choi, A Lam; Jang, Kyung Mi; Lee, Yul; Lee, Kwan Seop; Lee, Hyun; Sohn, Jeong Hee [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Kim, Sam Soo [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2009-12-15

    To evaluate the distribution of color flow signals on color Doppler ultrasonography of vascular leiomyomas and to correlate them with pathologic findings. We retrospectively analyzed color Doppler ultrasonographic images and pathologic slides of six vascular leiomyomas. We classified the patterns of distribution of color flow signals into localized compact cluster types and non-cluster types, and the pathologic findings into three subtypes: solid, venous and cavernous. All cases showed well-defined homogenous hypoechoic subcutaneous masses on gray-scale ultrasonography. Three cases showed localized compact cluster types on color Doppler ultrasonography, one in each subtype (solid, venous and cavernous). For the three non-cluster types, again there was on in each subtype. In addition, on pathologic analysis the zone of the localized compact cluster of color flow signals coincided with a cluster of larger, vascular caliber masses. Localized compact clusters of color flow signals on color Doppler ultrasonography were seen in 50% of our cases and correlated with a cluster of larger vascular caliber in the mass. But the pattern of distribution of color flows didn't show a correlation with pathologic type

  16. Color Doppler Ultrasonographic Findings of Vascular Leiomyoma: Pathologic Correlation

    International Nuclear Information System (INIS)

    Ko, Ji Young; Koh, Sung Hye; Min, Soo Kee; Choi, A Lam; Jang, Kyung Mi; Lee, Yul; Lee, Kwan Seop; Lee, Hyun; Sohn, Jeong Hee; Kim, Sam Soo

    2009-01-01

    To evaluate the distribution of color flow signals on color Doppler ultrasonography of vascular leiomyomas and to correlate them with pathologic findings. We retrospectively analyzed color Doppler ultrasonographic images and pathologic slides of six vascular leiomyomas. We classified the patterns of distribution of color flow signals into localized compact cluster types and non-cluster types, and the pathologic findings into three subtypes: solid, venous and cavernous. All cases showed well-defined homogenous hypoechoic subcutaneous masses on gray-scale ultrasonography. Three cases showed localized compact cluster types on color Doppler ultrasonography, one in each subtype (solid, venous and cavernous). For the three non-cluster types, again there was on in each subtype. In addition, on pathologic analysis the zone of the localized compact cluster of color flow signals coincided with a cluster of larger, vascular caliber masses. Localized compact clusters of color flow signals on color Doppler ultrasonography were seen in 50% of our cases and correlated with a cluster of larger vascular caliber in the mass. But the pattern of distribution of color flows didn't show a correlation with pathologic type

  17. Doppler ultrasonography of the pectinis oculi artery in harpy eagles ...

    African Journals Online (AJOL)

    Ibrahim Eldaghayes

    2017-03-21

    Güntürkün, 2000; Jones et al.,. 2007), accommodation by corneal and lenticular measures (Samuelson, 2007), bifoveate retinae. (Tucker, 2000), and an anangiotic (avascular) retina. (Ruggeri et al., 2010). As with all avian ...

  18. Doppler ultrasonography of the human fetal pulmonary circulation

    NARCIS (Netherlands)

    J.A.M. Laudij (Jacqueline)

    2000-01-01

    textabstractPulmonary hypoplasia is a condition characterized by a decrease in the number of lung cells, airways and alveoli with a resulting decrease in organ size and weight. The reported incidence of pulmonary hypoplasia in the general population is about 1 per 1000 live births and it is one of

  19. Doppler ultrasonography of the pectinis oculi artery in harpy eagles ...

    African Journals Online (AJOL)

    Low RI and PI values found in the harpy eagle´s pectinis oculi artery compared with the American pekin ducks one and other tissue suggest indeed a high metabolic activity in pecten oculi and corroborates the hypothesis of a nutritional function and/or intraocular pressure regulation. Keywords: Avian posterior segment, ...

  20. Use of Doppler ultrasound for non-invasive urodynamic diagnosis

    Directory of Open Access Journals (Sweden)

    Hideo Ozawa

    2009-01-01

    Full Text Available Objectives: A totally non-invasive transperineal urodynamic technique using Doppler ultrasonography has been developed. Methods: Since normal urine does not have blood cells, urine was thought not to produce the Doppler effects. However, basic studies confirmed that the decrease of pressure at high velocity (Bernouilli effect caused dissolved gas to form microbubbles, which are detected by Doppler ultrasonography. Subjects sat and the probe was advanced via remote control to achieve gentle contact with the perineal skin. The digital uroflow data signals and the color Doppler ultrasound video images were processed on a personal computer. The flow-velocity curves from two sites; the distal prostatic urethra just above the external sphincter (V1 and the sphincteric urethra (V2 were plotted against time. The parameters of both the pressure-flow studies and the Doppler ultrasound urodynamic studies were compared in men who had various degrees of obstruction. Results: Functional cross-sectional area at prostatic urethra (A1, calculated by Q max /V1, was lower in the group of bladder outlet obstruction (BOO vs. control group. Velocity ratio (VR, which was calculated by V1/V2, was the parameter having the best correlation with BOO index, though A1 had a similar correlation. This method is viable to diagnose the degree of BOO. Conclusions: The development of non-invasive Doppler ultrasound videourodynamics (Doppler UDS will dramatically expand the information on voiding function.

  1. Measurement of portal blood flow in healthy individuals: a comparison between magnetic resonance imaging and Doppler ultrasound

    International Nuclear Information System (INIS)

    Costa, Juliana Dantas da; Sebastiane, Patricia Moreno; Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; D'Ippolito, Giuseppe

    2008-01-01

    Objective: To evaluate the inter-observer agreement between Doppler ultrasonography and magnetic resonance imaging in the quantification of portal blood flow in healthy individuals, as well as evaluating the reproducibility of both methods. Materials and methods: A prospective, transverse, observational and self-paired study was developed evaluating 20 healthy volunteers whose portal blood flow was measured by means of Doppler ultrasonography and magnetic resonance imaging performed by two independent observers. Interobserver and inter method agreements were calculated using the intra class and Pearson's correlation coefficients. Results: The agreement between Doppler ultrasonography and magnetic resonance imaging was low (intra class coefficient: 1.9%-18.2%; Pearson's coefficient: 0.1%-13.7%; p=0.565). Mean values for the portal blood flow measured by Doppler ultrasonography and magnetic resonance imaging were respectively 0.768 l/min and 0.742 l/min. Interobserver agreement for quantification of the portal blood flow by Doppler ultrasonography and magnetic resonance imaging was respectively reasonable (intra class coefficient: 43.3%; Pearson's coefficient: 43.0%) and excellent (intra class coefficient: 91.4%; Pearson's coefficient: 93.4%). Conclusion: In the present study, magnetic resonance imaging demonstrated to be a reliable method for quantifying the portal blood flow, with a higher interobserver agreement than Doppler ultrasonography. The inter method agreement was low. (author)

  2. Ultrasonography of Neonatal Cholestasis

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, Jung Eun [Seoul National University Hospital, Seoul (Korea, Republic of)

    2012-06-15

    Ultrasonography (US) is as an important tool for differentiation of obstructive and non-obstructive causes of jaundice in infants and children. Beyond two weeks of age, extrahepatic biliary atresia and neonatal hepatitis are the two most common causes of persistent neonatal jaundice: differentiation of extrahepatic biliary atresia, which requires early surgical intervention, is very important. Meticulous analysis should focus on size and configuration of the gallbladder and anatomical changes of the portahepatis. In order to narrow the differential diagnosis, combined approaches using hepatic scintigraphy, MR cholangiography, and, at times, percutaneous liver biopsy are necessary. US is useful for demonstrating choledochal cyst, bile plug syndrome, and spontaneous perforation of the extrahepatic bile duct

  3. Ultrasonography of ovarian hyperandrogenemia

    Science.gov (United States)

    Kuzmina, Svetlana A.; Zharkin, Nikolay A.

    2001-05-01

    The method of ultrasonography is high informative and widely used in diagnostics of ovarian hyperandrogenaemia. The majority of authors consider that a hyperplasia of a stroma is the main pathognomonic marker of polycystic ovaries (PCO). Still recently swell of a stroma was valued visually, that had subjective nature. We offer for the first time a way of diagnostics of stromal hyperplasia grounded on measurement of a volume of a stroma and ovary with ultrasound method, calculation of the ratio of a volume of the ovary to a volume of a stroma for every patient.

  4. Evaluation of arterial embolization in treating hyperthyroidism by colour ultrasonography

    International Nuclear Information System (INIS)

    Sun Xiuying; Yang Jijin; Chen Ningning; Gu Limin; Wang Ying; Chen Jianquan

    2003-01-01

    Objective: To assess the effect of arterial embolization in treating hyperthyroidism by colour ultrasonography. Methods: Forty two cases of hyperthyroidism were treated with thyroid-arteries embolization. A few days before and 1, 3, 6 months after embolization, the echograms of thyroids were observed including the volumes of thyroids and the internal diameters of thyroid-arteries were measured with colour ultrasonography respectively. The Vs, Vd, Vm, PI, RI were measured with the Doppler and the quantities of blood flow were calculated. The relationships of changes for all these parameters and T 3 , T 4 and TSH were analysed. Results: Before artery embolization all thyroids were enlarged with diffusely homogenous or heterogenous low-echoes and nodules in some patients accompanied by widening of the thyroid arteries and their branches full of blood supply. The volume of thyroids decreased after artery embolization. 1-3 months later the echo of thyroids enhanced and got coarse with decrease of the thyroid vasculature and narrowing of vessel calibers except a few star- or stop-like blood streams were sometimes seen within the thyroids and no blood flow signals found in some cases. 3-6 months after embolization, the echo of thyroids decreased gradually or unevenly distributed. All the parameters of blood flow before and after the treatment showed statistically significant differences (P < 0.05). Conclusions: Embolization of thyroid arteries is a relatively new and effective technique in treating hyperthyroidism. Colour Doppler ultrasonography plays an important role for correct diagnosis and prognostication

  5. Doppler-ultrasonographic finding of air in the portal vein: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ki Soon; Lee, Kwan Sup; Lee, Yul; Chung, Soo Young; Bae, Sang Hoon [College of Medicine, Hallym University, Seoul (Korea, Republic of)

    1994-03-15

    Classically air in the portal vein has been detected on plain radiography, but computed tomography and ultrasonography have been shown to be more sensitive. We report a case of air in the PV in a 10-day-old infant with pneumatosis intestinalis with its ultrasonographic and Doppler findings. The patient was a 10-day-old infant born by cesarean section at 41 weeks. Simple abdomen film revealed branching pattern of radiolucent air shadows within in contour of liver, gas distention of bowel loops and thickenod bowel walls with lincar intraluminal air shadows in abdomen, suggesting necrotizing enterocolitis. So we performed Doppler ultrasonography. Ultrasonography showed branching pattern of hyperechogenic dots and along the lumen of left portal vein. The color Doppler study revealed an aliasing duo to increased velocity and whirling pattern of blood flow, and the Duplex Doppler spectral display showed sharp, vertical bidirectional spikes by air in portal vein. Air in the portal vein can be easily diagnosed by the following signs: hyperechogenic dots in the portal vein on ultrasonography and vertical, sharp bidirectional spikes superimposed on the usual Doppler tracing of the portal vein on Duplex ultrasonography.

  6. Doppler-ultrasonographic finding of air in the portal vein: a case report

    International Nuclear Information System (INIS)

    Park, Ki Soon; Lee, Kwan Sup; Lee, Yul; Chung, Soo Young; Bae, Sang Hoon

    1994-01-01

    Classically air in the portal vein has been detected on plain radiography, but computed tomography and ultrasonography have been shown to be more sensitive. We report a case of air in the PV in a 10-day-old infant with pneumatosis intestinalis with its ultrasonographic and Doppler findings. The patient was a 10-day-old infant born by cesarean section at 41 weeks. Simple abdomen film revealed branching pattern of radiolucent air shadows within in contour of liver, gas distention of bowel loops and thickenod bowel walls with lincar intraluminal air shadows in abdomen, suggesting necrotizing enterocolitis. So we performed Doppler ultrasonography. Ultrasonography showed branching pattern of hyperechogenic dots and along the lumen of left portal vein. The color Doppler study revealed an aliasing duo to increased velocity and whirling pattern of blood flow, and the Duplex Doppler spectral display showed sharp, vertical bidirectional spikes by air in portal vein. Air in the portal vein can be easily diagnosed by the following signs: hyperechogenic dots in the portal vein on ultrasonography and vertical, sharp bidirectional spikes superimposed on the usual Doppler tracing of the portal vein on Duplex ultrasonography

  7. Power doppler 'blanching' after the application of transducer pressure

    International Nuclear Information System (INIS)

    Joshua, F.; Edmonds, J.; Lassere, M.; De Carle, R.; Rayment, M.; Bryant, C.; Shnier, R.

    2005-01-01

    The aim of this study was to determine if transducer pressure modifies power Doppler assessments of rheumatoid arthritis synovium at the metacarpophalangeal joints and metatarsophalangeal joints. Five rheumatoid arthritis patients of varying degrees of 'disease activity' and damage were assessed with power Doppler ultrasound scanning of the dominant hand second to fifth metacarpophalangeal joints. Two rheumatoid arthritis patients had their dominant foot first to fifth metatarsophalangeal joints assessed with power Doppler ultrasound. Ultrasonography was performed with a high frequency transducer (14 MHz) with a colour mode frequency of 10 Mhz, and a standard colour box and gain. In the joint that showed the highest power Doppler signal, an image was made. A further image was taken after transducer pressure was applied. In all patients, there was increased flow to at least one joint. After pressure was applied, power Doppler signal intensity markedly reduced in all images and in some there was no recordable power Doppler signal. Increased transducer pressure can result in a marked reduction or obliteration in power Doppler signal. This power Doppler 'blanching' shows the need for further studies to evaluate sources of error and standardization before power Doppler ultrasound becomes a routine measure of 'disease activity' in rheumatoid arthritis. Copyright (2005) Blackwell Science Pty Ltd

  8. Ultrasonography in gastroenterology.

    Science.gov (United States)

    Ødegaard, Svein; Nesje, Lars B; Hausken, Trygve; Gilja, Odd Helge

    2015-06-01

    Ultrasonography (US) is a safe and available real-time, high-resolution imaging method, which during the last decades has been increasingly integrated as a clinical tool in gastroenterology. New US applications have emerged with enforced data software and new technical solutions, including strain evaluation, three-dimensional imaging and use of ultrasound contrast agents. Specific gastroenterologic applications have been developed by combining US with other diagnostic or therapeutic methods, such as endoscopy, manometry, puncture needles, diathermy and stents. US provides detailed structural information about visceral organs without hazard to the patients and can play an important clinical role by reducing the need for invasive procedures. This paper presents different aspects of US in gastroenterology, with a special emphasis on the contribution from Nordic scientists in developing clinical applications.

  9. Musculoskeletal ultrasonography in children

    International Nuclear Information System (INIS)

    Teo, E.-L.H.; Strouse, P.J.; Chhem, R.K.

    2002-01-01

    With the development of high-resolution ultrasound transducers, the role of ultrasonography (US) in evaluating the musculoskeletal system has increased. It is now possible to obtain detailed images of bones and soft-tissue structures that were previously unattainable. The advantages of US, when compared with other imaging modalities, are many. It is less expensive than magnetic resonance imaging (MRI) and computed tomography (CT). It does not expose the patient to ionizing radiation, so US examinations can be repeated without harm to the patient. Furthermore, US is performed in real-time, making it possible to assess the musculoskeletal system dynamically, in multiple planes and with contralateral comparison. In experienced hands, US is a quick, noninvasive and cost-effective way to assess the musculoskeletal system in children. It is used to evaluate soft-tissue masses, joint swelling, infections, lesions involving the chest and abdominal walls, bones, muscles and clubfoot deformity and to locate any foreign bodies. (author)

  10. Henoch-Schonlein purpura: ultrasonography of scrotal and penile involvement

    Directory of Open Access Journals (Sweden)

    Youngsik Lim

    2015-04-01

    Full Text Available Testicular or scrotal involvement has been reported in children with Henoch-Schonlein purpura (HSP, but there are very few reports on penile involvement. We report the initial and follow-up ultrasonographic findings of scrotal and penile involvement of HSP in a 5-year-old boy. On ultrasonography, scrotal soft tissue thickening and epididymal swelling with increased vascularity were noted, and on the penis, a focal mass-like lesion appeared on the dorsal surface of the distal penis, having a hypoechoic mass-like appearance without visible vascular flow on a Doppler study. After 2 days of treatment, follow-up ultrasonography showed normal scrotum and penis with a resolved soft tissue mass-like lesion. Therefore, we think that HSP ultrasonographic findings involving the scrotum and penis might help to diagnose scrotal and penile involvement in a case of HSP and to avoid unnecessary medication and/or surgical procedures.

  11. Doppler waveform of hepatic vein in patients with chronic hepatitis B; Correlation with histologic grade and stage

    International Nuclear Information System (INIS)

    Eom, Kyeong Tae; Namkung, Sook; Bae, Sang Hoon; Choi, Young Hee

    1999-01-01

    To evaluate the relationship between the waveform of the right hepatic vein and the histological grade and stage in patients with chronic hepatitis B. Eighty-seven patients with chronic hepatitis B were examined prospectively by one sonographer. In each patient, Doppler waveform of the right hepatic vein was obtained. Doppler waveform was classified into 3 type, type 0; normal triphasic pattern, type 1; reduced amplitude of phasic oscillation and no reverse flow phase, and type 2; completely flat flow pattern. In the same session, an ultrasound guided liver biopsy was performed and submitted to one pathologist for grading and staging. Duplex doppler ultrasonography of the right hepatic vein was also performed in 12 control subjects with no evidence of liver or heart disease. The doppler waveform was compared with the histologic severity and a statistical analysis was performed. In the control group, all cases had type 0 waveform. In the hepatitis group, there were type 0 waveform in 61 cases (70.1%), type 1 waveform in 22 cases (25.3%) and type 2 waveform in 4 cases (4.6%). The frequency of abnormal waveform is significantly higher in patients with grade 3-4 and stage 3-4 than grade and stage 1-2 (p>0.005). In the hepatitis group, the venous pulsatility index (VPI) was 0.17-0.69 (mean 0.41), and decreased in the highest and mean values when increasing the histologic scores. However, it was nor significant statistically (p>0.05). The frequency of abnormal waveform was correlated with the histologic severity in patients with chronic hepatitis B. The highest and mean values of the VPI were also correlated. However 70.1% of the patients with chronic hepatitis B showed normal waveform. So doppler ultrasonogram of the hepatic vein may be useful for the diagnosis and the differential diagnosis from cirrhosis in patients with chronic hepatitis B by combination of doppler waveform and venous pulsatility index.

  12. NEW EVIDENCE OF MAGNETIC INTERACTIONS BETWEEN STARS FROM THREE-DIMENSIONAL DOPPLER TOMOGRAPHY OF ALGOL BINARIES: {beta} PER AND RS VUL

    Energy Technology Data Exchange (ETDEWEB)

    Richards, Mercedes T. [Department of Astronomy and Astrophysics, Pennsylvania State University, 525 Davey Laboratory, University Park, PA 16802 (United States); Agafonov, Michail I.; Sharova, Olga I., E-mail: mrichards@astro.psu.edu, E-mail: agfn@nirfi.sci-nnov.ru, E-mail: shol@nirfi.sci-nnov.ru [Radiophysical Research Institute (NIRFI), 25/12a, Bolshaya Pecherskaya St., Nizhny Novgorod 603950 (Russian Federation)

    2012-11-20

    Time-resolved H{alpha} spectra of magnetically active interacting binaries have been used to create three-dimensional (3D) Doppler tomograms by means of the Radioastronomical Approach. This is the first 3D reconstruction of {beta} Per, with RS Vul for comparison. These 3D tomograms have revealed evidence of the mass transfer process (gas stream, circumprimary emission, localized region, absorption zone), as well as loop prominences and coronal mass ejections (CMEs) in {beta} Per and RS Vul that could not be discovered from two-dimensional tomograms alone. The gas stream in both binaries may have been deflected beyond the central plane by the donor star's magnetic field. The stream was more elongated along the predicted trajectory in RS Vul than in {beta} Per, but not as pronounced as in U CrB (stream state). The loop prominence reached maximum V{sub z} velocities of {+-}155 km s{sup -1} in RS Vul compared to {+-}120 km s{sup -1} in {beta} Per, while the CME reached a maximum V{sub z} velocity of +150 km s{sup -1} in RS Vul and +100 km s{sup -1} in {beta} Per. The 3D tomograms show that the gas flows are not symmetric relative to the central plane and are not confined to that plane, a result confirmed by recent 15 GHz VLBI radio images of {beta} Per. Both the 3D H{alpha} tomography and the VLBI radio images support an earlier prediction of the superhump phenomenon in {beta} Per: that the gas between the stars is threaded with a magnetic field even though the hot B8V mass-gaining star is not known to have a magnetic field.

  13. Transthoracic Ultrasonography for Clinicians

    Directory of Open Access Journals (Sweden)

    Morné Johan Vorster

    2015-04-01

    Full Text Available Transthoracic ultrasonography (US has become an essential tool for respiratory, emergency, and critical care physicians. It can be performed with basic equipment and by personnel with minimum training as a modality for the evaluation of a wide range of thoracic pathologies. Its advantages include immediate application at the point of care, low cost, and lack of radiation. The main indications for transthoracic US are the qualitative and quantitative assessment of pleural effusions, pleural thickening, diaphragmatic pathology, as well as chest wall and pleural tumors. Transthoracic US is also useful in visualizing pulmonary pathologies that abut the pleura, such as pneumonic consolidation and interstitial syndromes, including pulmonary edema. Transthoracic US is more sensitive than the traditional chest radiograph in the detection of pneumothoraces, and it is useful in diagnosing skeletal abnormalities such as rib fractures. It is the ideal tool to guide transthoracic procedures, including thoracocentesis and pleural biopsy. Moreover, transthoracic US-guided procedures can be performed by a single clinician with no sedation and minimal monitoring. Transthoracic US-guided fine needle aspiration and/or cutting needle biopsy of extrathoracic lymph nodes and lesions arising from the chest wall, pleura, peripheral lung, and mediastinum are safe to perform and have a high yield in the of hands of experienced clinicians. Transthoracic US can also potentially guide the aspiration and biopsy of diffuse pulmonary infiltrates, consolidations, and lung abscesses. Moreover, transthoracic US may be used in the detection of pulmonary embolism

  14. Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?

    Directory of Open Access Journals (Sweden)

    Lawrence H. Lin

    Full Text Available Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: “Gestational trophoblastic disease AND Ultrasonography, Doppler.” Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1 Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2 There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3 Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4 Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. CONCLUSION: Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.

  15. Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?

    Science.gov (United States)

    Lin, Lawrence H; Bernardes, Lisandra S; Hase, Eliane A; Fushida, Koji; Francisco, Rossana P V

    2015-12-01

    Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: "Gestational trophoblastic disease AND Ultrasonography, Doppler." Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1) Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2) There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3) Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4) Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.

  16. Prenatal color Doppler ultrasonographic diagnosis of fetal tetralogy of Fallot

    International Nuclear Information System (INIS)

    Tan Buqiao

    2009-01-01

    Objective: To investigate the sonographic findings of tetralogy of Fallot in fetuses. Methods: The data of color Doppler ultrasonography and follow-up results of 5 fetal tetralogy of Fallot were analyzed retrospectively, and their abnormal ultrasound imaging characteristic were summarized. Results: Two cases were proved tetralogy of Fallot by autopsy, and three cases were confirmed to be tetralogy of Fallot by echocardiography after birth. The image features were the main aorta situated above the ventricular septal defect, pulmonary stenosis, no obvious thickening of the right wall. Conclusion: Fetal tetralogy of Fallot have characteristic ultrasound images, prenatal color Doppler ultrasonographic can diagnoses fetal tetralogy of Fallot correctly and has important clinical value. (authors)

  17. Altered doppler flow patterns in cirrhosis patients: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Iranpour, Pooya; Lall, Chandana; Houshyar, Roozbeh; Helmy, Mohammad; Yang, Albert; Ward, Garrett; Goodwin, Scott C. [Dept. of Radiology, University of California Irvine, Orange (United States); Choi, Joon Il [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2016-01-15

    Doppler ultrasonography of the hepatic vasculature is an integral part of evaluating precirrhotic and cirrhotic patients. While the reversal of the portal venous flow is a well-recognized phenomenon, other flow patterns, although not as easily understood, may play an important role in assessing the disease status. This article discusses the different characteristic flow patterns observed from the portal vein, hepatic artery, and hepatic vein in patients with liver cirrhosis or related complications and procedures. Knowledge of these different flow patterns provides additional information that may reinforce the diagnosis of cirrhosis, help in staging, and offer prognostic information for determining the direction of therapy. Doppler ultrasonography is invaluable when liver transplantation is being considered and aids in the diagnosis of cirrhosis and portal hypertension.

  18. Transvaginal ultrasonography of rectal endometriosis

    DEFF Research Database (Denmark)

    Egekvist, Anne Gisselmann; Seyer-Hansen, Mikkel; Forman, Axel

    Objectives: The aim of this present study was to evaluate the interobserver variation of transvaginal ultrasonographic measurements of endometriosis infiltrating the rectosigmoid wall. Methods: Transvaginal ultrasonography was performed independently by two observers. Observer 1 had several years...... of experience in ultrasonography while observer 2 was a medical student with no prior experience in ultrasonography or endometriosis. In 24 patient length, width and depth of endometriosis infiltrating the rectosigmoid bowel was measured. The differences between the observers were analysed by Bland and Altman...... for a relatively short period gives comparable scanning results between the two observers. It seems that transvaginal ultrasound could be used as a diagnostic tool for rectal endometriosis in most departments. However, the irregular morphology of the lesions makes the measurements very complex, and a strict...

  19. Ultrasonography of the equine shoulder

    International Nuclear Information System (INIS)

    Dik, K.J.

    1996-01-01

    Six horses with shoulder injuries were presented in this report with emphasis on the use of ultrasonography vs. radiography in diagnosis. The two imaging modalities represented valuable and complementary diagnostic procedures. Two horses had fracture fragments of the lateral humeral tuberosity, the accurate ultrasonographic findings encouraging clearer radiographic identification by oblique projections. In one horseultrasonography enabled more accurate localization of calcification within the supraspinatus muscle. In the remaining three cases ultrasonography visualized distension of the bicipital bursa due to aseptic bursitis, bursal hemorrhage, or associated with injury of the biceps brachii muscle and the underlying intermediate humeral tubercle, the bony involvement more clearly demonstrated radiographically

  20. Sub-Doppler spectroscopy

    International Nuclear Information System (INIS)

    Hansch, T.W.

    1983-01-01

    This chapter examines Doppler-free saturation spectroscopy, tunable cw sources, and Doppler-free two-photon spectroscopy. Discusses saturation spectroscopy; continuous wave saturation spectroscopy in the ultraviolet; and two-photon spectroscopy of atomic hydrogen 1S-2S. Focuses on Doppler-free laser spectroscopy of gaseous samples. Explains that in saturation spectroscopy, a monochromatic laser beam ''labels'' a group of atoms within a narrow range of axial velocities through excitation or optical pumping, and a Doppler-free spectrum of these selected atoms is observed with a second, counterpropagating beam. Notes that in two-photon spectroscopy it is possible to record Doppler-free spectra without any need for velocity selection by excitation with two counterpropagating laser beams whose first order Doppler shifts cancel

  1. Doppler flowmetry in preeclampsia.

    Science.gov (United States)

    Zahumensky, J

    2009-01-01

    The purpose of this study was to summarize the new published data on the Doppler flowmetry in preeclampsia. We summarize the new published data on the Doppler flowmetry in uteroplacental, fetoplacental and fetal circulation in preeclampsia. The present review summarized the results of clinical research on the Doppler flowmetry in the screening of risk of preclampsia, in the diagnosis of preclampsia and in the fetal risk in preclampsia (Ref. 19). Full Text (Free, PDF) www.bmj.sk.

  2. [The diagnostic value of ultrasonic elastography and ultrasonography comprehensive score in cervical lesions].

    Science.gov (United States)

    Lu, R; Xiao, Y

    2017-07-18

    Objective: To evaluate the clinical value of ultrasonic elastography and ultrasonography comprehensive scoring method in the diagnosis of cervical lesions. Methods: A total of 116 patients were selected from the Department of Gynecology of the first hospital affiliated with Central South University from March 2014 to September 2015.All of the lesions were preoperatively examined by Doppler Ultrasound and elastography.The elasticity score was determined by a 5-point scoring method. Calculation of the strain ratio was based on a comparison of the average strain measured in the lesion with the adjacent tissue of the same depth, size, and shape.All these ultrasonic parameters were quantified, added, and arrived at ultrasonography comprehensive scores.To use surgical pathology as the gold standard, the sensitivity, specificity, accuracy of Doppler Ultrasound, elasticity score and strain ratio methods and ultrasonography comprehensive scoring method were comparatively analyzed. Results: (1) The sensitivity, specificity, and accuracy of Doppler Ultrasound in diagnosing cervical lesions were 82.89% (63/76), 85.0% (34/40), and 83.62% (97/116), respectively.(2) The sensitivity, specificity, and accuracy of the elasticity score method were 77.63% (59/76), 82.5% (33/40), and 79.31% (92/116), respectively; the sensitivity, specificity, and accuracy of the strain ratio measure method were 84.21% (64/76), 87.5% (35/40), and 85.34% (99/116), respectively.(3) The sensitivity, specificity, and accuracy of ultrasonography comprehensive scoring method were 90.79% (69/76), 92.5% (37/40), and 91.38% (106/116), respectively. Conclusion: (1) It was obvious that ultrasonic elastography had certain diagnostic value in cervical lesions. Strain ratio measurement can be more objective than elasticity score method.(2) The combined application of ultrasonography comprehensive scoring method, ultrasonic elastography and conventional sonography was more accurate than single parameter.

  3. Ultrasonography of the Rotator Cuff

    International Nuclear Information System (INIS)

    Yoon, Yong Cheol

    2006-01-01

    The ultrasonography (US) is an important modality in evaluating shoulder disease. It is accurate in diagnosing the various shoulder diseases including tendinosis, calcific tendinitis, and subacromial bursitis as well as rotator cuff tears. This article presents a pictorial review of US anatomy of the shoulder, the technical aspects of shoulder US, major types of shoulder pathology, and interventional procedure under US guidance

  4. Ultrasonography of the Rotator Cuff

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yong Cheol [Samsung Medica Center, Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of)

    2006-09-15

    The ultrasonography (US) is an important modality in evaluating shoulder disease. It is accurate in diagnosing the various shoulder diseases including tendinosis, calcific tendinitis, and subacromial bursitis as well as rotator cuff tears. This article presents a pictorial review of US anatomy of the shoulder, the technical aspects of shoulder US, major types of shoulder pathology, and interventional procedure under US guidance

  5. The diagnosis of deep venous thrombosis using laser Doppler skin perfusion measurements

    NARCIS (Netherlands)

    de Graaff, J. C.; Ubbink, D. T.; Büller, H. R.; Jacobs, M. J.

    2001-01-01

    Compression ultrasonography (CUS) falls short in the diagnosis of deep venous thrombosis in asymptomatic patients and thrombi limited to the calf veins. Alternatively, laser Doppler fluxmetry (LDF) may be useful for this purpose, as it can measure the peripheral vasoconstriction response upon an

  6. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    Peripheral vascular disease - Doppler; PVD - Doppler; PAD - Doppler; Blockage of leg arteries - Doppler; Intermittent claudication - Doppler; Arterial insufficiency of the legs - Doppler; Leg pain and ...

  7. Differential doppler heterodyning technique

    DEFF Research Database (Denmark)

    Lading, Lars

    1971-01-01

    Measuring velocity without disturbing the moving object is possible by use of the laser doppler heterodyning technique. Theoretical considerations on the doppler shift show that the antenna property of the photodetector can solve an apparent conflict between two different ways of calculating...

  8. Doppler ultrasound monitoring technology.

    Science.gov (United States)

    Docker, M F

    1993-03-01

    Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.

  9. The Cognitive Doppler.

    Science.gov (United States)

    Kozoil, Micah E.

    1989-01-01

    Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…

  10. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  11. Diagnostic nerve ultrasonography; Diagnostische Nervensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Baeumer, T. [Universitaet zu Luebeck CBBM, Haus 66, Institut fuer Neurogenetik, Luebeck (Germany); Grimm, A. [Universitaetsklinikum Tuebingen, Klinik und Poliklinik fuer Neurologie, Tuebingen (Germany); Schelle, T. [Staedtisches Klinikum Dessau, Neurologische Klinik, Dessau (Germany)

    2017-03-15

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [German] Fuer die Diagnostik von Nervenlaesionen ist ein bildgebendes Verfahren zur Darstellung des peripheren Nervs und seiner ihn umgebenden Strukturen fuer eine aetiologische Einordnung erforderlich. Mit der klinisch-neurologischen Untersuchung und Elektrophysiologie ist eine funktionelle Aussage ueber die Nervenlaesion moeglich. In der Standard-MRT-Untersuchung wird der periphere Nerv nur unzureichend gut dargestellt. Die MRT-Neurographie ist ein sehr gutes, aber auch zeit- und ressourcenintensives Verfahren. Nutzung des Ultraschalls fuer die

  12. Screening ultrasonography of 2,204 patients with blunt abdominal trauma in the Wenchuan earthquake.

    Science.gov (United States)

    Zhou, Jixiang; Huang, Jiwei; Wu, Hong; Jiang, Hui; Zhang, Heqing; Prasoon, Pankaj; Xu, Yinglong; Bai, Yannan; Qiu, Jianguo; Zeng, Yong

    2012-10-01

    Abdominal injuries constitute a small proportion of all earthquake-related traumas; however, it often resulted in fatal hemorrhage. Ultrasonography has been described as an effective triage tool in the evaluation of blunt abdominal trauma. We aimed to present an overview of the diagnostic accuracy of screening ultrasonography for patients with blunt abdominal trauma admitted to various hospitals during the Wenchuan earthquake in China. We retrospectively analyzed the patients with blunt abdominal trauma who underwent ultrasonography after admission to various hospitals. Ultrasonography findings were considered positive if evidence of free fluid or a parenchymal injury was identified. Ultrasonography findings were compared with the findings of computed tomography, diagnostic peritoneal lavage, repeated ultrasonography, cystography, operation, and/or the clinical course. Findings from 2,204 ultrasonographic examinations were evaluated. Findings of 199 ultrasonographic examinations (9.0%) were considered positive. Of the patients, 12 (0.5%) had a false-negative ultrasonographic findings; of this group, 3 (25%) required exploratory laparotomy. Ultrasonography had a sensitivity of 91.9%, specificity of 96.9%, and an accuracy of 96.6% for detection of abdominal injuries. Positive predictive value was 68.3%, and negative predictive value was 99.4%. Screening ultrasonography is highly reliable in the setting of blunt abdominal trauma after earthquake. It should be used as an initial diagnostic modality in the evaluation of most blunt abdominal trauma. Diagnostic study, level III.

  13. Patients with sickle cell disease are frequently excluded from the benefits of transcranial doppler screening for the risk of stroke despite extensive and compelling evidence

    Directory of Open Access Journals (Sweden)

    Daniela Laranja Gomes Rodrigues

    Full Text Available ABSTRACT Transcranial doppler (TCD is a strategic component of primary stroke prevention in children with sickle cell disease (SCD. This study was conducted to examine the TCD characteristics of children with SCD in nine different medical centers in Brazil. Methods: Transcranial doppler was performed in accordance with the Stroke Prevention Trial in Sickle Cell Anemia Protocol. Results: Of the 396 patients, 69.5% had homozygous SS hemoglobin. The TCD result was abnormal in 4.8%, conditional in 12.6%, inadequate in 4.3% and abnormally low in 1% of patients. The highest mean flow velocities were 121±23.83cm/s and 124±27.21cm/s in the left and right middle cerebral artery respectively. A total of 28.8% patients (mean age 9.19±5.92 years were evaluated with TCD for the first time. Conclusions: The SCD patients were evaluated with TCD at an older age, representing an important missed opportunity for stroke prevention. Since TCD screening in patients with SCD is important to detect those at high risk for stroke, it is recommended that this screening should be made more readily available.

  14. TORSION TESTIS : ROLE OF COLOR DOPPLER : A STUDY OF 50 CASES

    Directory of Open Access Journals (Sweden)

    Anand

    2015-09-01

    Full Text Available BACKGROUND: T orsion testis is one of the catast r ophic conditions in children and young a d u lts. Traditionally the diagnosis was made clinical presentation and suspicion. Critical decision making is essential to save the testis . OBJECTIVE: To study the usefu lness and efficacy of Doppler ultrasound in correctly diagnosing acute scrotal conditions in children and young adults to save the testis and to avoid negative explorations. METHODS: Over a period of two years 50 patients with acute scrotum were admitted i n general surgery department who underwent Doppler ultrasound scrotum and its efficacy in correctly diagnosing the pathology was analysed. RESULTS: 50 patients with age group <25 years were included in study. Scrotal pain was the most frequent presenting s ymptom of acute scrotum (98% followed by Swelling of the hemiscrolum on the involved side present in 86% of the patients. Doppler ultrasound showed torsion of testis in 18 patients. On Scrotal exploration, torsion of spermatic cord was confirmed in 16 pat ients, one patient had torsion of appendix of testis and the other had Epididymo - orchitis. Thus the sensitivity and specificity of Doppler ultrasonography for testicular torsion was 86.9% and 92.6% respectively. 2 patients with equivocal Doppler findings, but strong clinical suspicion of testicular torsion were explored, and testis was found to be torsed in both two patients. Doppler ultrasonography showed Epididymo - orchitis in 22 patients, torsion of testicular appendage in 2 patients, Idiopathic scrotal edema in one, and in 5 pts no significant pathology found. All twenty patients of epididymo - orchitis, two patients of torsion of testicular appendage, and one patient of idiopathic scrotal edema were managed conservatively. At three weeks follow up, all th e patients were free of symptoms. The sensitivity and specificity of Doppler ultrasonography for epididymo - orchitis was 95% and 100% respectively. CONCLUSIONS: color

  15. Ultrasound and Doppler examination capabilities in adult portal hypertension type definition

    Directory of Open Access Journals (Sweden)

    N. V. Tumanskaya

    2015-08-01

    Full Text Available Early portal hypertension type diagnostics is an ultimate factor concerning kind and tactics of treatment. Aim. To objectify ultrasound examination capabilities, portal hemodynamics were studied in 97 patients using impulse and color doppler. Methods and results. It was ascertained that impulse and color doppler examination allows to visualize portal vein and its branches’ structural abnormalities, define subhepatic and intrahepatic types of portal hypertension, find thrombosis and characterize its stages. In cirrhosis patients with portal hypertension, homogenous doppler signal was received from the portal vessels lumen, while signs of intraluminar pathology were seen in the case of thrombosis of portal vein. Conclusion. This means that ultrasound examination of portal vein and its branches with impulse and color doppler is informative, non invasive method, which helps to define stages of portal hypertension. Doppler ultrasonography doesn’t have negative effect of ionizing radiation and can be used for the repeated research in the dynamics of disease.

  16. Ultrasonography findings of gastric carcinoma

    International Nuclear Information System (INIS)

    Chung, Chong Ku; Choi, Ji Bai; Ko, Young Tae; Lim, Jae Hoon; Kim, Soon Young

    1985-01-01

    Stomach carcinoma is more common disease in Korea than western countries. The reported ultrasonographic findings of gastric carcinoma were thickening of gastric wall and 'pseudokidney' sign. The author analyzed ultrasonographic findings of 101 cases with gastric carcinoma who were performed ultrasonography and gastroscopy at Kyung Hee University Hospital from October 1982 to October 1985. The results were as followings; 1. Types of gastric carcinoma were consisted with infiltrative type 68 cases, infiltrative type with ulceration 16 cases, polypoid type with ulceration 1 case, infiltrative adn polypoid type 4 cases, limits plastica type 3 cases, ulcerative type 1 case and polypoid type 1 case. 2. Extent of the lesions were in body and antrum 45 cases, entire stomach 18 cases, antrum 18 cases, body 12 cases, body and fundus 6 cases. 3. Ultrasonography was useful in demonstrating the extent of the tumor and the presence of materials elsewhere in abdomen

  17. Ultrasonography findings of gastric carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Chong Ku; Choi, Ji Bai; Ko, Young Tae; Lim, Jae Hoon; Kim, Soon Young [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1985-12-15

    Stomach carcinoma is more common disease in Korea than western countries. The reported ultrasonographic findings of gastric carcinoma were thickening of gastric wall and 'pseudokidney' sign. The author analyzed ultrasonographic findings of 101 cases with gastric carcinoma who were performed ultrasonography and gastroscopy at Kyung Hee University Hospital from October 1982 to October 1985. The results were as followings; 1. Types of gastric carcinoma were consisted with infiltrative type 68 cases, infiltrative type with ulceration 16 cases, polypoid type with ulceration 1 case, infiltrative adn polypoid type 4 cases, limits plastica type 3 cases, ulcerative type 1 case and polypoid type 1 case. 2. Extent of the lesions were in body and antrum 45 cases, entire stomach 18 cases, antrum 18 cases, body 12 cases, body and fundus 6 cases. 3. Ultrasonography was useful in demonstrating the extent of the tumor and the presence of materials elsewhere in abdomen.

  18. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncica, Ana Maria; Saftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...

  19. Abdominal ultrasonography, 2nd Ed

    International Nuclear Information System (INIS)

    Goldberg, B.B.

    1984-01-01

    This volume is a new and updated edition of an extensively illustrated text and reference on the capabilities and imaging of gray scale ultrasonography for each major abdominal organ. Each major organ system is treated separately, including liver, gallbladder and bile ducts, pancreas, kidney, retroperitoneum, abdominal vasculature, and more. There are over 500 illustrations and ten pages of full color plates for cross sectional anatomy

  20. Thyroid ultrasonography: Pitfalls and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seon hyeong; Kim, Eun Kyung; Kim, Soo Jin; Kwak, Jin Young [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-04-15

    Thyroid ultrasonography (US) plays a key role in the diagnosis and management of thyroid-related diseases. The aim of this article was to illustrate various pitfalls that can occur in utilizing thyroid US and techniques to prevent them. In this article, we present cases demonstrating the common pitfalls associated with US equipment, performance, normal thyroid structures, misinterpretations, and surrounding structures. Knowledge of these areas is essential to avoid misdiagnosis or improper disease management.

  1. Doppler radar flowmeter

    Science.gov (United States)

    Petlevich, Walter J.; Sverdrup, Edward F.

    1978-01-01

    A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.

  2. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  3. Incidentally diagnosed Takayasu arteritis on thyroid ultrasonography showing prominent collateral vessels of thyroidal arteries and common carotid artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Se Jin; Kim, Eun Kyung [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-10-15

    We report a case of middle-aged woman incidentally diagnosed with Takayasu arteritis during the ultrasonography of a thyroid gland nodule. Prominent collaterals of the thyroidal arteries and a thin common carotid artery with mural thickening and deficient intraluminal flow signals were initially depicted on the ultrasonography with color Doppler. Subsequent magnetic resonance angiography and computed tomography aortography confirmed the diagnosis with the imaging features of a bilateral long segment common carotid artery occlusion and segmental stenosis of the left subclavian artery in addition to the suggestive physical findings.

  4. Validation of ultrasonography in detecting structural disease of the urogenital tract of the koala, Phascolarctos cinereus.

    Science.gov (United States)

    Marschner, C; Flanagan, C; Higgins, D P; Krockenberger, M B

    2014-05-01

    A retrospective review of case records of ultrasonography and necropsy outcomes of 62 koalas was used to investigate the accuracy of ultrasonography in assessing koala urogenital tract structural disease at the Port Macquarie Koala Hospital. The results showed high concordance, supporting ultrasonography as an effective tool for evaluating structural disease of the koala urogenital tract, most commonly seen with chlamydiosis. The study also illustrates the advances benefiting animal welfare that can be made by wildlife carer groups through using a scientific, evidence-based approach. © 2014 Australian Veterinary Association.

  5. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  6. International guidelines for contrast-enhanced ultrasonography

    DEFF Research Database (Denmark)

    Nolsøe, Christian Pállson; Lorentzen, Torben

    2016-01-01

    The intent of this review is to discuss and comment on common clinical scenarios in which contrast-enhanced ultrasonography (CEUS) may play a decisive role and to illustrate important points with typical cases. With the advent of CEUS, the scope of indications for ultrasonography has been dramati...

  7. The phenomenon of Doppler

    International Nuclear Information System (INIS)

    Stoll, I.; Seidlerova, I.; Schwippel, J.; Poss, O.; Solc, M.

    1992-01-01

    The book is devoted to the life and work of Christian Doppler and particularly to his links to Prague and to the Slovak town of Banska Stiavnica. Many historical facts concerning Doppler's activities as well as the history of physics and astronomy are collected. Information is also presented about the Czech Technical University, the Society of Czechoslovak Mathematicians and Physicists, the Czechoslovak Astronomical Society, the Czechoslovak Spectroscopic Society and the Czechoslovak Society for the History of Science and Technology. The publication is amply supplemented with historical pictorial material (M.D.). 92 figs., 82 refs

  8. Doppler radar physiological sensing

    CERN Document Server

    Lubecke, Victor M; Droitcour, Amy D; Park, Byung-Kwon; Singh, Aditya

    2016-01-01

    Presents a comprehensive description of the theory and practical implementation of Doppler radar-based physiological monitoring. This book includes an overview of current physiological monitoring techniques and explains the fundamental technology used in remote non-contact monitoring methods. Basic radio wave propagation and radar principles are introduced along with the fundamentals of physiological motion and measurement. Specific design and implementation considerations for physiological monitoring radar systems are then discussed in detail. The authors address current research and commercial development of Doppler radar based physiological monitoring for healthcare and other applications.

  9. Doppler ion program description

    International Nuclear Information System (INIS)

    Henline, P.

    1980-12-01

    The Doppler spectrometer is a conventional Czerny-Turner grating spectrometer with a 1024 channel multiple detector. Light is dispersed across the detector, and its output yields a spectrum covering approximately 200 A. The width of the spectral peak is directly proportional to the temperature of the emitting ions, and determination of the impurity ion temperature allows one to infer the plasma ion temperature. The Doppler ion software system developed at General Atomic uses a TRACOR Northern 1710-31 and an LSI-11/2. The exact configuration of Doublet III is different from TRACOR Northern systems at other facilities

  10. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  11. Comparative evaluation of ultrasonography, computed tomography and magnetic resonance imaging in the follow-up of Budd-Chiari syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Legmann, P; Levesque, M; De, Broucker F; F,; Hay, J M; Maillard, J N

    1988-01-01

    A comparative evaluation of ultrasonography, computed tomography and MRI in 8 patients operated for Budd-Chiari syndrome is reported. The results obtained, evaluated separately for each technique and then compared between each other and with the data of superior coelio-mesenteric angiography and inferior cavography, show that the MRI data is very clearly superior to the data obtained by ultrasonography and computed tomography. MRI allows simultaneous assessment of the hepatic parenchyma, evaluation of portal hypertension and the porto-caval anastomosis, which are all essential elements in the follow-up Budd-Chiari syndrome. However, in the light of the literature, the authors stress that ultrasonography associated with pulsed Doppler also ensures satisfactory vascular and parenchymal assessment of this disease in the majority of cases.

  12. Comparative evaluation of ultrasonography, computed tomography and magnetic resonance imaging in the follow-up of Budd-Chiari syndrome

    International Nuclear Information System (INIS)

    Legmann, P.; Levesque, M.; Broucker, F. de; Hay, J.M.; Maillard, J.N.

    1989-01-01

    The authors report a comparative evaluation of ultrasonography, computed tomography and MRI in 8 patients operated for Budd-Chiari syndrome. The results obtained, evaluated separately for each technique and then compared between each other and with the data of superior coelio-mesenteric angiography and inferior cavography, showed that MRI data is very clearly superior to the data obtained by ultrasonography and computed tomography. MRI allows simultaneous assessment of the hepatic parenchyma, and evaluation of portal hypertension and the porto-caval anastomosis, which are all essential elements in the follow-up Budd-Chiari syndrome. However, in the light of the literature, the authors stress that ultrasonography associated with pulsed Doppler also ensures satisfactory vascular and parenchymal assessment of this disease in the majority of cases [fr

  13. Comparison of Radiography and Ultrasonography for Diagnosis of Diaphragmatic Hernia in Bovines

    Directory of Open Access Journals (Sweden)

    Hakim Athar

    2010-01-01

    Full Text Available The present study was conducted on 101 animals suffering from thoracoabdominal disorders; out of which twenty seven animals (twenty six buffaloes and one cow were diagnosed with diaphragmatic hernia based on clinical signs, radiography, ultrasonography, and left flank laparorumenotomy. Radiography alone confirmed diaphragmatic hernia in 18 cases (66.67% with a sac-like structure cranial to the diaphragm. In 15 animals the sac contained metallic densities while in three cases a sac-like structure with no metallic densities was present. Ultrasonography was helpful in confirming diaphragmatic hernia in 23 cases (85.18% and ultrasonographically reticular motility was evident at the level of 4th/5th intercostal space in all the animals. B+M mode ultrasonography was used for the first time for diagnosis of diaphragmatic hernia in bovines and the results suggested that ultrasonography was a reliable diagnostic modality for diaphragmatic hernia in bovines.

  14. Accuracy of doppler ultrasound in diagnosis of endometrial carcinoma

    International Nuclear Information System (INIS)

    Batool, S.; Raza, S.; Manzur, S.

    2013-01-01

    Objective: To determine the accuracy of Doppler ultrasound in the diagnosis of endometrial carcinoma in patients presenting with post-menopausal bleeding while taking histopathological findings as the gold standard. Methods: The cross-sectional study was done at the Department of Radiology, Bahawal Victoria Hospital, Bahawalpur, from April 1 to September 30, 2009, and comprised 128 patients above 50 years of age having history of post-menopausal bleeding and who were referred to the department. Name, age and hospital registration number were recorded on a proforma. Doppler ultrasound was performed and endometrial thickness and uterine artery resistive index were recorded on transabdominal ultrasonography. Patients with endometrial thickness of more than 5mm and uterine artery resistive index of less than 0.7 were considered to be having endometrial carcinoma. Histopathology findings were also recorded using the hospital registration number of the patient. The findings of Doppler ultrasound scan were validated with the findings of histopathology. Results: Of the 128 patients, 48 (37.5%) were between the ages of 51 and 55 years; 46 (35.93%) were in the 56-60 age group; and 34 (26.57%) were over 65 years. On the basis of Doppler ultrasound findings, 106 (82.8%) patients were diagnosed as having endometrial carcinoma, while 22 (17.19%) were declared negative. Ultrasonography results were compared with histopathology findings. The percentages of true positive, true negative, false positive and false negative were calculated. There were 103 (80.47%) true positive; 12 (9.37%) false positive; 10 (7.81%) true negative; and 3 (2.35%) false negative. Specificity, sensitivity, positive predictive value and negative predictive value were found to be 97.16%, 76%, 89.56% and 76.92% respectively. Conclusion: The use of Doppler ultrasonography in non-invasive diagnosis of endometrial carcinoma in patients presenting with post-menopausal bleeding was quite useful with good

  15. Doppler evaluation of valvular stenosis

    International Nuclear Information System (INIS)

    Kisslo, J.; Krafchek, J.; Adams, D.; Mark, D.B.

    1986-01-01

    One of the reasons why use of Doppler echocardiography is growing rapidly is because of its utility in detecting the presence of valvular stenosis and in estimating its severity. Detection of the presence of stenotic valvular heart disease using Doppler echocardiography was originally described over 10 years ago. It has been demonstrated that Doppler blood velocity data could be used to estimate the severity of a stenotic lesion. This chapter discusses the evaluation of valvular stenois using Doppler

  16. Doppler-musical instrument

    International Nuclear Information System (INIS)

    Sato, T.J.; Watanabe, N.

    2001-01-01

    We propose a possible ultra-high energy resolution backscattering spectrometer optimized to spallation neutron source. A combination of multi monochromator crystal and Doppler drive provides considerable neutron flux, together with the reasonable energy range -30 < E < 30 μeV, even when the ultra-high energy resolution of ΔE∼0.03 μeV is attained. (author)

  17. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  18. II Brazilian consensus statement on endoscopic ultrasonography.

    Science.gov (United States)

    Maluf-Filho, Fauze; de Oliveira, Joel Fernandez; Mendonça, Ernesto Quaresma; Carbonari, Augusto; Maciente, Bruno Antônio; Salomão, Bruno Chaves; Medrado, Bruno Frederico; Dotti, Carlos Marcelo; Lopes, César Vivian; Braga, Cláudia Utsch; M Dutra, Daniel Alencar; Retes, Felipe; Nakao, Frank; de Sousa, Giovana Biasia; de Paulo, Gustavo Andrade; Ardengh, Jose Celso; Dos Santos, Juliana Bonfim; Sampaio, Luciana Moura; Okawa, Luciano; Rossini, Lucio; de Brito Cardoso, Manoel Carlos; Ribeiro Camunha, Marco Antonio; Clarêncio, Marcos; Lera Dos Santos, Marcos Eduardo; Franco, Matheus; Schneider, Nutianne Camargo; Mascarenhas, Ramiro; Roda, Rodrigo; Matuguma, Sérgio; Guaraldi, Simone; Figueiredo, Viviane

    2017-01-01

    At the time of its introduction in the early 80s, endoscopic ultrasonography (EUS) was indicated for diagnostic purposes. Recently, EUS has been employed to assist or to be the main platform of complex therapeutic interventions. From a series of relevant new topics in the literature and based on the need to complement the I Brazilian consensus on EUS, twenty experienced endosonographers identified and reviewed the pertinent literature in databases. The quality of evidence, strength of recommendations, and level of consensus were graded and voted on. Consensus was reached for eight relevant topics: treatment of gastric varices, staging of nonsmall cell lung cancer, biliary drainage, tissue sampling of subepithelial lesions (SELs), treatment of pancreatic fluid collections, tissue sampling of pancreatic solid lesions, celiac neurolysis, and evaluation of the incidental pancreatic cysts. There is a high level of evidence for staging of nonsmall cell lung cancer; biopsy of SELs as the safest method; unilateral and bilateral injection techniques are equivalent for EUS-guided celiac neurolysis, and in patients with visible ganglia, celiac ganglia neurolysis appears to lead to better results. There is a moderate level of evidence for: yield of tissue sampling of pancreatic solid lesions is not influenced by the needle shape, gauge, or employed aspiration technique; EUS-guided and percutaneous biliary drainage present similar clinical success and adverse event rates; plastic and metallic stents are equivalent in the EUS-guided treatment of pancreatic pseudocyst. There is a low level of evidence in the routine use of EUS-guided treatment of gastric varices.

  19. Neurilemmoma of the glans penis: ultrasonography and magnetic resonance imaging findings.

    Science.gov (United States)

    Jung, Dae Chul; Hwang, Sung Il; Jung, Sung Il; Kim, Sun Ho; Kim, Seung Hyup

    2006-01-01

    Neurilemmoma of the glans penis is rare, and no imaging findings have been reported. A case of neurilemmoma of the glans penis is presented. Ultrasonography (US) and magnetic resonance imaging revealed a well-defined small mass in the glans penis. The mass appeared hypoechoic on gray-scale US and hypervascular on color Doppler US. Magnetic resonance imaging revealed high signal intensity of the mass on a T2-weighted image and strong enhancement on a contrast-enhanced T1-weighted image.

  20. [Ultrasonography in acute pelvic pain].

    Science.gov (United States)

    Kupesić, Sanja; Aksamija, Alenka; Vucić, Niksa; Tripalo, Ana; Kurjak, Asim

    2002-01-01

    Acute pelvic pain may be the manifestation of various gynecologic and non-gynecologic disorders from less alarming rupture of the follicular cyst to life threatening conditions such as rupture of ectopic pregnancy or perforation of inflamed appendix. In order to construct an algorithm for differential diagnosis we divide acute pelvic pain into gynecologic and non-gynecologic etiology, which is than subdivided into gastrointestinal and urinary causes. Appendicitis is the most common surgical emergency and should always be considered in differential diagnosis if appendix has not been removed. Apart of clinical examination and laboratory tests, an ultrasound examination is sensitive up to 90% and specific up to 95% if graded compression technique is used. Still it is user-depended and requires considerable experience in order to perform it reliably. Meckel's diverticulitis, acute terminal ileitis, mesenteric lymphadenitis and functional bowel disease are conditions that should be differentiated from other causes of low abdominal pain by clinical presentation, laboratory and imaging tests. Dilatation of renal pelvis and ureter are typical signs of obstructive uropathy and may be efficiently detected by ultrasound. Additional thinning of renal parenchyma suggests long-term obstructive uropathy. Ruptured ectopic pregnancy, salpingitis and hemorrhagic ovarian cysts are three most commonly diagnosed gynecologic conditions presenting as an acute abdomen. Degenerating leiomyomas and adnexal torsion occur less frequently. For better systematization, gynecologic causes of acute pelvic pain could be divided into conditions with negative pregnancy test and conditions with positive pregnancy test. Pelvic inflammatory disease may be ultrasonically presented with numerous signs such as thickening of the tubal wall, incomplete septa within the dilated tube, demonstration of hyperechoic mural nodules, free fluid in the "cul-de-sac" etc. Color Doppler ultrasound contributes to more

  1. Role of color Doppler in differentiation of Graves' disease and thyroiditis in thyrotoxicosis

    Science.gov (United States)

    Donkol, Ragab Hani; Nada, Aml Mohamed; Boughattas, Sami

    2013-01-01

    AIM: To evaluate the role of thyroid blood flow assessment by color-flow Doppler ultrasonography in the differential diagnosis of thyrotoxicosis and compare it to technetium pertechnetate thyroid scanning. METHODS: Twenty-six patients with thyrotoxicosis were included in the study. Clinical history was taken and physical examination and thyroid function tests were performed for all patients. Thyroid autoantibodies were measured. The thyroid glands of all patients were evaluated by gray scale ultrasonography for size, shape and echotexture. Color-flow Doppler ultrasonography of the thyroid tissue was performed and spectral flow analysis of both inferior thyroid arteries was assessed. Technetium99 pertechnetate scanning of the thyroid gland was done for all patients. According to thyroid scintigraphy, the patients were divided into two groups: 18 cases with Graves’ disease and 8 cases with Hashimoto’s thyroiditis. All patients had suppressed thyrotropin. The diagnosis of Graves’ disease and Hashimoto’s thyroiditis was supported by the clinical picture and follow up of patients. RESULTS: Peak systolic velocities of the inferior thyroid arteries were significantly higher in patients with Graves’ disease than in patients with thyroiditis (P = 0.004 in the right inferior thyroid artery and P = 0.001 in left inferior thyroid artery). Color-flow Doppler ultrasonography parameters demonstrated a sensitivity of 88.9% and a specificity of 87.5% in the differential diagnosis of thyrotoxicosis. CONCLUSION: Color Doppler flow of the inferior thyroid artery can be used in the differential diagnosis of thyrotoxicosis, especially when there is a contraindication of thyroid scintigraphy by radioactive material in some patients. PMID:23671754

  2. Role of ultrasonography in detecting mammographically occult breast carcinoma in women with dense breasts.

    Science.gov (United States)

    Corsetti, V; Ferrari, A; Ghirardi, M; Bergonzini, R; Bellarosa, S; Angelini, O; Bani, C; Ciatto, S

    2006-04-01

    The purpose of this study was to assess the usefulness of routine ultrasonography in women with negative mammography and dense breasts [Breast Imaging Reporting and Data System (BIRADS D3-4)]. We applied a protocol involving routine ultrasonography in a consecutive series of subjects with negative mammography and dense breasts. After evaluation by internal and external reviewers of cancers detected by ultrasonography performed to confirm negative mammography, we determined the additional cancer detection rate of ultrasonography and the cost of the protocol. Out of 17,883 total mammographies, 167 cancers were diagnosed (detection rate: 0.93%). Out of 257 suspicious mammographies, 138 cancers were detected. Out of 17,626 negative mammographies, 6,449 (36.5%) were classified as "dense breast" and underwent ultrasonography: 29 cancers were detected (detection rate: 0.44%, or 17.3% of total cancers). Out of 25 cancer cases reviewed, negative mammography and asymptomatic status was confirmed in 15 (detection rate 0.23%, or 8.9% of total cancers). The cancer detection rate was 0.11%, 0.22%, 0.32% and 0.14% for age groups 59, respectively. The cost per additional carcinoma detected by ultrasonography alone was euro 25,847.85 whereas that per examined woman was euro 21.68. The study confirms the possibility that ultrasonography can detect mammographically occult breast carcinoma in dense breasts. The evidence is insufficient to recommend this policy in routine screening practice but suggests that, at least in current clinical practice, adding ultrasonography in dense breasts may be useful despite the substantial costs.

  3. Is ultrasonography essential before surgery in eyes with advanced cataracts?

    Directory of Open Access Journals (Sweden)

    Salman Amjad

    2006-01-01

    Full Text Available Background: Ultrasonography is an important tool for evaluating the posterior segment in eyes with opaque media. Aim: To study the incidence of posterior segment pathology in eyes with advanced cataract and to see whether certain features could be used as predictors for an abnormal posterior segment on ultrasound. Setting: Tertiary care hospital in South India. Methods and Materials: In this prospective study conducted over a 6-month period, all eyes with dense cataracts precluding visualization of fundus underwent assessment with ultrasound. Presence of certain patient and ocular "risk" factors believed to be associated with a higher incidence of abnormal posterior segment on ultrasound were looked for and the odds ratio (OR for posterior segment pathology in these eyes was calculated. Results: Of the 418 eyes assessed, 36 eyes (8.6% had evidence of posterior segment pathology on ultrasound. Retinal detachment (17 eyes; 4.1% was the most frequent abnormality detected. Among patient features, diabetes mellitus (OR= 4.9, P=0.003 and age below 50 years (OR= 15.4, P=0.001 were associated with a high incidence of abnormal ultrasound scans. In ocular features, posterior synechiae (OR= 20.2, P=0.000, iris coloboma (OR= 34.6, P=0.000, inaccurate projection of rays (OR= 15.1, P=0.002, elevated intraocular pressure (OR= 15.1, P=0.004, and keratic precipitates (OR= 22.4, P=0.004 were associated with high incidence of posterior segment pathology. Only four eyes (1.5% without these features had abnormal posterior segment on ultrasonography. Conclusions: Certain patient and ocular features are indicative of a high risk for posterior segment pathology and such patients should be evaluated by ultrasonography prior to cataract surgery. In the absence of these risk factors, the likelihood of detecting abnormalities on preoperative ultrasonography in eyes with advanced cataracts is miniscule.

  4. Deep vein thrombosis of lower extremity: What is the most important finding in duplex Doppler sonography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Soo; Koh, Byung Hee; Cho, On Koo; Rhim, Hyun Chul; Seo, Heung Suk; Hahm, Chang Kok; Kwak, Jin Young [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    1993-12-15

    The positive findings of deep vein thrombosis on duplex Doppler ultrasonography such as intraluminal clot,non-compressibility of the venous lumen and abnormal or absent Doppler shift signal are well known. However, relatively hypoechoic thrombus is not always seen in sonography, and the vein is frequently compressible in partial thrombosis. In order to evaluate the most common and important findings of deep vein thrombosis, we analysed the findings at duplex Doppler ultrasound in 19 patients and compared the results with those of contrast venography in 11 patients. Duplex Doppler ultrasound examination of the common femoral and popliteal veins was performed for one extremity in 14 patients, and for both extremities in 5 (total 24 extremities). Contrast venography was performed for one extremity in 7 patients, and for both sides in 4 (total 15 extremities).Thrombosis was seen in 45.8%, non-compressibility of lumen in 75%, absent or decreased Doppler signal from common femoral vein in 95.8%. Thrombosis was seen in 41.7%, non-compressibility of lumen in 70.8%, absent or decreased Doppler shift signal from popliteal vein in 95.8%. We conclude that abnormal or absent Doppler shift signal is the most sensitive and important finding of the deep vein thrombosis

  5. [Vascular complications following kidney transplant: the role of color-Doppler imaging].

    Science.gov (United States)

    Granata, Antonio; Floccari, Fulvio; Lentini, Paolo; Vittoria, Salvatore; Di Pietro, Fabio; Zamboli, Pasquale; Fiorini, Fulvio; Fatuzzo, Pasquale

    2012-01-01

    The progressive decline in the incidence of graft rejection has made urological, surgical, parenchymal and vascular complications of kidney transplant more frequent. The latter, although accounting for only 5-10% of all post-transplant complications, are a frequent cause of graft loss. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of parenchymal and surgical complications of the transplanted kidney, its role is not fully understood in case of vascular complications of the graft. The specificity of Doppler ultrasound is very important in case of stenosis of the transplanted renal artery, pseudoaneurysms, arteriovenous fistulas, and thrombosis with complete or partial artery or vein occlusion. Doppler and color determinations present high diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of vascular complications of the transplanted kidney, planted kidney.

  6. Contrast-enhanced endoscopic ultrasonography in digestive diseases.

    Science.gov (United States)

    Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2012-10-01

    Contrast-enhanced endoscopic ultrasonography (CE-EUS) was introduced in the early 1990s. The concept of the injection of carbon dioxide microbubbles into the hepatic artery as a contrast material (enhanced ultrasonography) led to "endoscopic ultrasonographic angiography". After the arrival of the first-generation contrast agent, high-frequency (12 MHz) EUS brought about the enhancement of EUS images in the diagnosis of pancreatico-biliary diseases, upper gastrointestinal (GI) cancer, and submucosal tumors. The electronic scanning endosonoscope with both radial and linear probes enabled the use of high-end ultrasound machines and depicted the enhancement of both color/power Doppler flow-based imaging and harmonic-based imaging using second-generation contrast agents. Many reports have described the usefulness of the differential diagnosis of pancreatic diseases and other abdominal lesions. Quantitative evaluation of CE-EUS images was an objective method of diagnosis using the time-intensity curve (TIC), but it was limited to the region of interest. Recently developed Inflow Time Mapping™ can be generated from stored clips and used to display the pattern of signal enhancement with time after injection, offering temporal difference of contrast agents and improved tumor characterization. On the other hand, three-dimensional CE-EUS images added new information to the literature, but lacked positional information. Three-dimensional CE-EUS with accurate positional information is awaited. To date, most reports have been related to pancreatic lesions or lymph nodes. Hemodynamic analysis might be of use for diseases in other organs: upper GI cancer diagnosis, submucosal tumors, and biliary disorders, and it might also provide functional information. Studies of CE-EUS in diseases in many other organs will increase in the near future.

  7. Doppler-musical instrument

    Energy Technology Data Exchange (ETDEWEB)

    Sato, T.J. [National Research Institute for Metals, Tsukuba, Ibaraki (Japan); Watanabe, N. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Shibata, K. [Institute for Materials Research, Tohoku Univ., Sendai, Miyagi (Japan)

    2001-03-01

    We propose a possible ultra-high energy resolution backscattering spectrometer optimized to spallation neutron source. A combination of multi monochromator crystal and Doppler drive provides considerable neutron flux, together with the reasonable energy range -30 < E < 30 {mu}eV, even when the ultra-high energy resolution of {delta}E{approx}0.03 {mu}eV is attained. (author)

  8. Imaging of the acute scrotum: is there a place for contrast-enhanced ultrasonography?

    Directory of Open Access Journals (Sweden)

    H. Moschouris

    2009-12-01

    Full Text Available Purpose: To present and evaluate the findings of contrast-enhanced ultrasonography (CEUS in typical cases of acute painful scrotum. Materials and methods: Nineteen patients aged from 19 to 61 years old were included in the study. All patients underwent grey-scale and color Doppler ultrasonography (US of the scrotum, followed by imaging after i.v. administration of 2.4 mL of a second generation ultrasound contrast agent (microbubbles of sulphur hexafluoride. A dedicated, contrast-sensitive technique was used (Contrast Tissue Imaging - CnTI. The diagnosis was confirmed surgically in 6 cases while in the remaining 8 cases it was based on the combination of clinical, imaging and laboratory findings. Results: The final diagnosis was testicular torsion (n = 4, epididymitis (n = 2, one of the cases complicated by abscess, testicular abscess (n = 1, scrotal abscess (n = 1, testicular trauma of varying severity (n = 6. Five out of 19 cases were true negatives: neither clinical examination nor laboratory tests revealed any pathology. CEUS showed complete lack of enhancement in all cases of torsion, permitting a rapid and definitive diagnosis. In the cases of infection complicated by abscesses, CEUS delineated the lesions much better than the combination of B-mode/Color Doppler US. The severely traumatized testicles showed minimal, inhomogeneous or patchy enhancement, while cases of minor trauma showed no significant enhancement defects. Hematomas were presented as non-enhancing lesions. Conclusion: Generally, there was no advantage over Doppler US as has been previously shown. However, CEUS can be used supplementary to traditional Doppler US in the investigation of blunt testicular trauma especially when there is uncertainty in diagnosis after appropriate clinical and radiographic evaluations occurs. Further studies are required to clearly define the indications of this method.

  9. Numerical stud of glare spot phase Doppler anemometry

    OpenAIRE

    Hespel , Camille; Ren , Kuan Fang; Gréhan , Gérard; Onofri , Fabrice

    2008-01-01

    International audience; The phase Doppler anemometry has (PDA) been developed to measure simultaneously the velocity and the size of droplets. When the concentration of particles is high, tightly focused beams must be used, as in the dual burst PDA. The latter permits an access to the refractive index of the particle, but the effect of wave front curvature of the incident beams becomes evident. In this paper, we introduce a glare spot phase Doppler anemometry which uses two large beams. The i...

  10. Ultrasonography in chronic renal failure

    International Nuclear Information System (INIS)

    Buturovic-Ponikvar, Jadranka; Visnar-Perovic, Alenka

    2003-01-01

    Many chronic renal diseases lead to the final common state of decrease in renal size, parenchymal atrophy, sclerosis and fibrosis. The ultrasound image show a smaller kidney, thinning of the parenchyma and its hyperechogenicity (reflecting sclerosis and fibrosis). The frequency of renal cysts increases with the progression of the disease. Ultrasound generally does not allow for the exact diagnosis of an underlying chronic disease (renal biopsy is usually required), but it can help to determine an irreversible disease, assess prognosis and avoid unnecessary diagnostic or therapeutic procedures. The main exception in which the ultrasound image does not show a smaller kidney with parenchymal atrophy is diabetic nephropathy, the leading cause of chronic and end-stage renal failure in developed countries in recent years. In this case, both renal size and parenchymal thickness are preserved until end-stage renal failure. Doppler study of intrarenal vessels can provide additional information about microvascular and parenchymal lesions, which is helpful in deciding for or against therapeutic intervention and timely planning for optimal renal replacement therapy option

  11. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  12. Prenatal Diagnosis of Sacrococcygeal Teratoma Using Two and Three-Dimensional Ultrasonography

    Directory of Open Access Journals (Sweden)

    Livia Teresa Moreira Rios

    2012-01-01

    Full Text Available Sacrococcygeal teratoma accounts for half of all fetal tumors, with a prevalence of 1 : 40,000 births. It is believed to originate from pluripotent cells in Hensen's nodule. Although most are benign, they are associated with high morbidity and mortality rates because the fetus develops congestive heart failure and hydrops. Factors leading to poor prognosis include solid components in the mass, and hydrops diagnosed before the 30th week. A case of prenatal sacrococcygeal teratoma diagnosed using B-mode and color Doppler two-dimensional ultrasonography (2DUS is described, in which three-dimensional ultrasonography (3DUS enabled characterization of the extent of fetal lesions and allowed the parents to understand the pathological condition better. A 20-year-old primigravida was referred with a solid mass diagnosed in the lumbosacral spine. Examinations performed at our institution revealed pregnancy of 23 weeks and 4 days, with a female fetus presenting a bulky solid mass with cystic components and calcifications, measuring 7.7×9.1×12.2 cm, starting from the sacral region, with internal flow seen on color Doppler. A new ultrasound confirmed fetal death at 25 weeks and 4 days. Postnatal findings confirmed the diagnosis of sacrococcygeal teratoma. 3DUS can be used in cases of sacrococcygeal teratoma to assess the development of tumor during the prenatal and to allow better understanding of this anomaly by the parents.

  13. Ultrasonography and surgery of canine biliary diseases.

    Science.gov (United States)

    Vörös, K; Németh, T; Vrabély, T; Manczur, F; Tóth, J; Magdus, M; Perge, E

    2001-01-01

    Findings of hepatic and gallbladder ultrasonography were analyzed in 12 dogs with gallbladder and/or extrahepatic biliary tract obstruction and compared with the results of exploratory laparotomy. Hepatic ultrasonography demonstrated normal liver in 2 dogs and hepatic abnormalities in 10 animals. The following ultrasonographic diagnoses were established compared to surgical findings: gallbladder obstruction caused by bile sludge (correct/incorrect: 1/2, surgical diagnosis: choleliths in one case), gallbladder obstruction caused by neoplasm (0/1, surgical diagnosis: mucocele), gallbladder and extrahepatic biliary tract obstruction due to choleliths (3/3), extrahepatic biliary tract obstruction caused by pancreatic mass (1/1) and small intestinal volvulus (1/1). Bile peritonitis caused by gallbladder rupture (4/4) was correctly diagnosed by ultrasound, aided with ultrasonographically-guided abdominocentesis and peritoneal fluid analysis. Rupture of the gallbladder should be suspected in the presence of a small, echogenic gallbladder or in the absence of the organ together with free abdominal fluid during ultrasonography. Laparotomy was correctly indicated by ultrasonography in all cases. However, the direct cause of obstruction could not be determined in 2 of the 12 dogs by ultrasonography alone.

  14. Role of Ultrasonography in Acute Abdomen

    International Nuclear Information System (INIS)

    An, Ji Hyun; Lee, Yeon Hee; Kim, Tae Hoon; Yu, Pil Mun; Choi, Young Hi; Kim, Sang Joon; Kim, Seung Cheul; Cho, Jeong Hee; Jung, Jae Un

    1996-01-01

    Authors analyzed the distribution of diseases and compared ultrasonographic conclusions with confirmed diagnoses of emergency abdominal ultrasonographies in acute abdominal conditions. We evaluated the role of emergency abdominal ultrasonography especially in the decision of emergency operation. In one hundred and forty five patients, emergent abdominal ultrasonography was performed within on admission. We compared the sonographic conclusion with postoperative pathology and analyzed the diagnoses of medically treated diseases. Twenty-eight patients under vent surgery and 117 patients were treated conservatively. Among the surgically treated patients, 19 patients (70.4%) were correctly diagnosed by preoperative ultrasonography.These included acute appendicitis (N = 8), acute cholecystitis (n = 7), ovarian cyst torsion (n = 2), and liver abscess (n = 1). Correct preoperative diagnosis was not made in 9 patients, including acute appendicitis (n = 4),peritonitis due to bowel perforation (n = 2), ectopic pregnancy (n = 1), colonic diverticulitis (n = 1 ) and pelvic inflammatory disease (n = 1 ). Clinical follow up was possible in 50 patients among the non-operative patient group, and the clinical diagnoses were chronic liver disease (n = 14), acute pyelonephritis (n = 10), and biliary stone (n = 10). Emergent ultrasonography plays an important role in acute abdominal conditions by supporting the differential diagnosis of medical and surgical disease

  15. Role of Ultrasonography in Acute Abdomen

    Energy Technology Data Exchange (ETDEWEB)

    An, Ji Hyun; Lee, Yeon Hee; Kim, Tae Hoon; Yu, Pil Mun; Choi, Young Hi; Kim, Sang Joon; Kim, Seung Cheul; Cho, Jeong Hee [Dankook University College of Medicine, Cheonan (Korea, Republic of); Jung, Jae Un [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1996-12-15

    Authors analyzed the distribution of diseases and compared ultrasonographic conclusions with confirmed diagnoses of emergency abdominal ultrasonographies in acute abdominal conditions. We evaluated the role of emergency abdominal ultrasonography especially in the decision of emergency operation. In one hundred and forty five patients, emergent abdominal ultrasonography was performed within on admission. We compared the sonographic conclusion with postoperative pathology and analyzed the diagnoses of medically treated diseases. Twenty-eight patients underwent surgery and 117 patients were treated conservatively. Among the surgically treated patients, 19 patients (70.4%) were correctly diagnosed by preoperative ultrasonography.These included acute appendicitis (N = 8), acute cholecystitis (n = 7), ovarian cyst torsion (n = 2), and liver abscess (n = 1). Correct preoperative diagnosis was not made in 9 patients, including acute appendicitis (n = 4), peritonitis due to bowel perforation (n = 2), ectopic pregnancy (n = 1), colonic diverticulitis (n = 1) and pelvic inflammatory disease (n = 1). Clinical follow up was possible in 50 patients among the non-operative patient group, and the clinical diagnoses were chronic liver disease (n = 14), acute pyelonephritis (n = 10), and biliary stone (n = 10). Emergent ultrasonography plays an important role in acute abdominal conditions by supporting the differential diagnosis of medical and surgical disease

  16. Pulsed and Color Doppler Sonographic Findings of Penile Mondor' Disease

    Energy Technology Data Exchange (ETDEWEB)

    Han, Hye Yeon; Chung, Dong Jin; Kim, Kum Won; Hwang, Cheol Mog [University of Konyang School of Medicine, Daejeon (Korea, Republic of)

    2008-04-15

    Penile Mondor's disease is a rare disease that's characterized by thrombosis in the dorsal vein of the penis. Doppler ultrasonography (US) clearly visualizes dorsal vein thrombosis and the associated hemodynamic alterations. Previous studies have demonstrated the typical color Doppler US findings of superficial dorsal vein thrombosis without the flow signals in this area, yet this is insufficient to understand the hemodynamics in penile Mondor's disease. We report here for the first time a cavernosal artery flow signal pattern in a penile Mondor's disease patient, in addition to its previously reported classic US findings. In conclusion, the Doppler US findings of thrombus without blood flow in the superficial dorsal vein and the low-flow, high resistance in the cavernosal artery may be suggestive of penile Mondor's disease.

  17. Power Doppler sonography and ultrasound contrast agent in assessing rheumatoid synovitis

    Directory of Open Access Journals (Sweden)

    F. Salaffi

    2011-09-01

    Full Text Available Pannus formation is a fundamental event in the pathogenesis of rheumatoid arthritis and its hypervascularisation seems to be crucial to the development of joint damage. High-resolution greyscale ultrasonography is a safe, quick, and inexpensive imaging tool that allows an accurate detection of even minimal morphostructural changes in patients with rheumatoid arthritis, including joint effusion, thickening of synovial membrane and bone erosions. More recently, power Doppler sonography has proved to be a reliable tool for semiquantitative assessment of the vascularity of the synovial tissue. The contrast-enhanced power Doppler sonography seems to be a helpful adjunct in assessing synovitis and the therapeutic response to the different therapies in patients with rheumatoid arthritis. The aim of this radiological vignette was to show a representative example of use of power Doppler sonography with contrast agent in assessing rheumatoid synovitis.

  18. Evaluation of diagnosis of small breast cancer with high frequency and color doppler ultrasound

    International Nuclear Information System (INIS)

    Xia Guobing; Hu Chunhong; Jing Qiulong

    2008-01-01

    Objective: To probe the features of high frequency ultrasonography (HFU) and color Doppler ultrasound (CDU) in the case of small breast cancers in order to evaluate the diagnostic value for small breast cancer with CDU. Methods: The features of HFU and CDU were respective analyzed in 67 small breast masses, the biggest diameter of which was under 2cm identified with pathology. Results Partially characteristic changes of small breast cancers were displayed, and micro-calcification within the mass was an important characteristic, in addition, the Resistant Index (RI) ≥ 0.70 on Pulsed Doppler (PD) and the grade of blood flow on Color Doppler Flow Imaging (CDFI)≥T2 implied much more positive malignancy prediction. Conclusion: HFU integrated with CDU can be used for the early and accurate diagnosis of the small breast cancer. (authors)

  19. Applications of Ultrasonography in Female Lower Urinary Tract Symptoms: Diagnosis and Intervention

    Directory of Open Access Journals (Sweden)

    Wen-Chen Huang

    2004-09-01

    Full Text Available Lower urinary tract symptoms (LUTS are a common health problem causing considerable inconvenience to many women. Moreover, they are non-specific and can be caused by a large number of disorders. A thorough evaluation, including physical examination, imaging studies, and urodynamic investigation of the lower urinary tract, is crucial for appropriate management of bothersome symptoms. Ultrasonography has the advantages of non-invasiveness, reproducibility, no radiation exposure, and low cost. With the use of a high-resolution transducer, pelvic organs can be demonstrated clearly on ultrasonography. In addition, three-dimensional sonography provides a clear demonstration of the spatial orientation of the female lower urinary tract. Both color and power Doppler scanning can not only reveal the vascular flow in pelvic organs, but also demonstrate urinary flow. Ultrasonography has dual functions in the management of female LUTS: diagnosis and intervention. It may help physicians to recognize the anatomic characteristics of specific pelvic floor disorders, to explore the pathophysiologic mechanism responsible for pelvic floor dysfunction, and to assist in the surgical management of LUTS with minimal invasion. Since female LUTS may originate from gynecologic or nongynecologic conditions, it is more convenient and helpful to obtain transvaginal and introital sonograms at the same time by using an endovaginal probe.

  20. Musculoskeletal ultrasonography delineates ankle symptoms in rheumatoid arthritis.

    Science.gov (United States)

    Toyota, Yukihiro; Tamura, Maasa; Kirino, Yohei; Sugiyama, Yumiko; Tsuchida, Naomi; Kunishita, Yosuke; Kishimoto, Daiga; Kamiyama, Reikou; Miura, Yasushi; Minegishi, Kaoru; Yoshimi, Ryusuke; Ueda, Atsuhisa; Nakajima, Hideaki

    2017-05-01

    To clarify the use of musculoskeletal ultrasonography (US) of ankle joints in rheumatoid arthritis (RA). Consecutive RA patients with or without ankle symptoms participated in the study. The US, clinical examination (CE), and patients' visual analog scale for pain (pVAS) for ankles were assessed. Prevalence of tibiotalar joint synovitis and tenosynovitis were assessed by grayscale (GS) and power Doppler (PD) US using a semi-quantitative grading (0-3). The positive US and CE findings were defined as GS score ≥2 and/or PD score ≥1, and joint swelling and/or tenderness, respectively. Multivariate analysis with the generalized linear mixed model was performed by assigning ankle pVAS as a dependent variable. Among a total of 120 ankles from 60 RA patients, positive ankle US findings were found in 21 (35.0%) patients. The concordance rate of CE and US was moderate (kappa 0.57). Of the 88 CE negative ankles, US detected positive findings in 9 (10.2%) joints. Multivariate analysis revealed that ankle US, clinical disease activity index, and foot Health Assessment Questionnaire, but not CE, was independently associated with ankle pVAS. US examination is useful to illustrate RA ankle involvement, especially for patients who complain ankle pain but lack CE findings.

  1. Principles of doppler tomography

    International Nuclear Information System (INIS)

    Juhlin, P.

    1992-08-01

    This paper shows how the radon transform can be used to determine vector fields. A scheme to determine the velocity field of a moving fluid by measurements with a continuous doppler signal is suggested. When the flow is confined to a bounded domain, as is the case in most applications, it can be uniquely decomposed into one gradiental and one rotational part. The former vanishes if the fluid is incompressible and source-free, and the latter can be completely reconstructed by the methods proposed in this paper if the domain is simply connected. Special attention is paid to laminar flow in a long cylindrical vessel with circular cross-section. Under such conditions the flow profile becomes parabolic, which makes the vessel recognizable as a typical 'N-shaped' pattern in an image describing the rotation of the velocity field. The vessel yields the same doppler tomographic pattern, no matter how it is sectioned. The ideas presented should be applicable also when studying the flow in blood vessels, even if the flow profile in these is not quite parabolic. The discrepancies only make the 'N-shape' somewhat distorted

  2. Comparisons between PW Doppler system and enhanced FM Doppler system

    DEFF Research Database (Denmark)

    Wilhjelm, Jens E.; Pedersen, P. C.

    1995-01-01

    This paper presents a new implementation of an echo-ranging FM Doppler system with improved performance, relative to the FM Doppler system reported previously. The use of long sweeps provides a significant reduction in peak to average power ratio compared to pulsed wave (PW) emission. A PW Doppler...... system exploits the direct relationship between arrival time of the received signal and range from the transducer. In the FM Doppler systems, a similar relationship exists in the spectral domain of the demodulated received signals, so that range is represented by frequency. Thus, a shift in location...... of moving scatterers between consecutive emissions corresponds to a frequency shift in the spectral signature. The improvement relative to the earlier version of the FM Doppler system is attained by utilizing cross-correlation of real spectra rather than of magnitude spectra for assessing flow velocity...

  3. Lenticulostriate vasculopathy of brain ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Soo Mee; Lee, Min Hee; Kim, Ha Na; Baek, Seung Yon; Lee, Sun Wha [Ewha Woman' s Univ. Mokdong Hospital, Seoul (Korea, Republic of)

    1997-05-01

    To describe the associated conditions and clinical significance of lenticulostriate uasculopathy (LSV) as demonstrated by cranial sonography. We retrospectively studied 77 LSV cases who between January 1994 and January 1996 had undergone cranial sonography for neonatal asphyxia, seizure, or bulging of anterior fontanel. Cranial sonography was performed with 7MHz real-time linear and sector transducers using an Acuson computed sonography unit;examinations were performed in sagittal and coronal planes. Twenty-six LSV patients underwent color Doppler studies, and in 24 of these, color signal and arterial pulse spectral wave were detected. LSV was grouped as one of three types, according to echogenicity:type I (less echogenic than sylvian fissure), type II (similar to sylvian fissure), and type III (more echogenic than sylvian fissures). We retrospectively evaluated associated sonographic abnormalities of the brain, and reviewed medical records for associated conditions and neurologic sequelae. Follow-up sonographic examinations were performed in 23 patients. There were 56 type I cases (73%), 17 of type II (22%) and 4 of type III (5%). Cranial sonographic results were normal in 36 cases (47%) and abnormal in 41(53%). Forty-eight cases of nonspecific causes and 29 cases of perinatal and acquired causes accounted for associated conditions. The echogenicity of LSV had not changed in 21 of 23 follow-up cases. Neurologic examinations were performed in 18 cases and in 14 of these (78%) there was no neurologic sequela. LSV in basal ganglia may be associated with nonspecific neonatal conditions, in addition to well known perinatal causes.

  4. The use of ultrasonography in pediatric ophthalmology - diagnostics of ophthalmic disorders in newborns and infants

    International Nuclear Information System (INIS)

    Modrzejewska, M.; Karczewicz, D.; Wilk, G.

    2006-01-01

    Ultrasonographic (US) examinations in ophthalmology play a major role as one of the additional examination modes in the diagnostics of orbital diseases, and in cases of changes of a vascular origin it is useful in the evaluation of blood flow velocity. The special value of this examination in the assessment of the opaque optical structures on the fundus of the eye is emphasized. The aim of the study was 1) to present the ultrasonographic images and the efficacy of the method in the evaluation of some congenital and acquired bulbar diseases and 2) on the bases of the advantages of the examination, to determine whether ultrasonography could be included as a screening method in the diagnostics of preterm infants as well as a method of choice in term infants with ophthalmologic diseases. One thousand sixty-two children between the ages of 3 weeks to 12 months, of whom 1135 were preterm and 27 term infants, with ophthalmologic changes were examined. A real-time ultrasonographic apparatus with color Doppler (5-7.5 MHz sectoral and 7.5-10 MHz linear transducers). The US examinations of preterm infants were conducted four times and in term infants twice. In 105 children (8.99%) and in 184 eyes, premature retinopathy, intra-bulbar tumors, retinal ablation, posttraumatic changes, inflammatory processes in the posterior chamber of the eyeball, and congenital anomalies of the bulbar structures were diagnosed. Bulbar ultrasonography, being a safe, quick, and efficient examination, should be included as an additional screening method in preterm infants. Ultrasonography with color Doppler is an efficient method of choice for diagnosing problematic diseases of the eyeballs of infants. (author)

  5. Scintigraphy and ultrasonography of various thyroid diseases

    International Nuclear Information System (INIS)

    Ban, Yoshio; Nagakura, Hozumi; Kawauchi, Akihiro; Fukunari, Nobuhiro; Itoh, Kunihiko; Higashi, Tomomitsu.

    1987-01-01

    We reported the usefulness of scintigraphy and ultrasonography of various thyroid diseases. The scintigraphy were useful information in the determination of functioning adenoma, location of ectopic thyroid glands and appearance of lang and bone metastasis of thyroid carcinoma. As ultrasonography were able to be observation of internal structure of thyroid gland, that maight be used to determined associated nodular lesions in diffuse goiter and differentiation between benign and malignant tumor in nodular goiter. In observation of calcifications of goiter, soft X rays apparatus were usefull tool. US, as initial diagnostic test before scintiscanning, provided useful information and minimized radiation exposure. (author)

  6. Imaging in early rheumatoid arthritis: roles of magnetic resonance imaging, ultrasonography, conventional radiography and computed tomography

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Ejbjerg, Bo; Szkudlarek, Marcin

    2005-01-01

    Efficient methods for diagnosis, monitoring and prognostication are essential in early rheumatoid arthritis (RA). While conventional X-rays only visualize the late signs of preceding disease activity, there is evidence for magnetic resonance imaging (MRI) and ultrasonography being highly sensitiv...

  7. Deconvoluting double Doppler spectra

    International Nuclear Information System (INIS)

    Ho, K.F.; Beling, C.D.; Fung, S.; Chan, K.L.; Tang, H.W.

    2001-01-01

    The successful deconvolution of data from double Doppler broadening of annihilation radiation (D-DBAR) spectroscopy is a promising area of endeavour aimed at producing momentum distributions of a quality comparable to those of the angular correlation technique. The deconvolution procedure we test in the present study is the constrained generalized least square method. Trials with computer simulated DDBAR spectra are generated and deconvoluted in order to find the best form of regularizer and the regularization parameter. For these trials the Neumann (reflective) boundary condition is used to give a single matrix operation in Fourier space. Experimental D-DBAR spectra are also subject to the same type of deconvolution after having carried out a background subtraction and using a symmetrize resolution function obtained from an 85 Sr source with wide coincidence windows. (orig.)

  8. Adaptive Spectral Doppler Estimation

    DEFF Research Database (Denmark)

    Gran, Fredrik; Jakobsson, Andreas; Jensen, Jørgen Arendt

    2009-01-01

    . The methods can also provide better quality of the estimated power spectral density (PSD) of the blood signal. Adaptive spectral estimation techniques are known to pro- vide good spectral resolution and contrast even when the ob- servation window is very short. The 2 adaptive techniques are tested......In this paper, 2 adaptive spectral estimation techniques are analyzed for spectral Doppler ultrasound. The purpose is to minimize the observation window needed to estimate the spectrogram to provide a better temporal resolution and gain more flexibility when designing the data acquisition sequence...... and compared with the averaged periodogram (Welch’s method). The blood power spectral capon (BPC) method is based on a standard minimum variance technique adapted to account for both averaging over slow-time and depth. The blood amplitude and phase estimation technique (BAPES) is based on finding a set...

  9. Emergency surgeon-performed hepatobiliary ultrasonography.

    LENUS (Irish Health Repository)

    Kell, M R

    2012-02-03

    BACKGROUND: Acute hepatobiliary pathology is a common general surgical emergency referral. Diagnosis requires imaging of the biliary tree by ultrasonography. The accuracy and impact of surgeon-performed ultrasonography (SUS) on the diagnosis of emergent hepatobiliary pathology was examined. METHODS: A prospective study, over a 6-month period, enrolled all patients with symptoms or signs of acute hepatobiliary pathology. Patients provided informed consent and underwent both SUS and standard radiology-performed ultrasonography (RUS). SUS was performed using a 2-5-MHz broadband portable ultrasound probe by two surgeons trained in ultrasonography, and RUS using a 2-5-MHz fixed unit. SUS results were correlated with those of RUS and pathological diagnoses. RESULTS: Fifty-three consecutive patients underwent 106 ultrasonographic investigations. SUS agreed with RUS in 50 (94.3 per cent) of 53 patients. SUS accurately detected cholelithiasis in all but two cases and no patient was inaccurately diagnosed as having cholelithiasis at SUS (95.2 per cent sensitivity and 100 per cent specificity). As an overall complementary diagnostic tool SUS provided the correct diagnosis in 96.2 per cent of patients. Time to scan was significantly shorter following SUS (3.1 versus 12.0 h, P < 0.05). CONCLUSION: SUS provides a rapid and accurate diagnosis of emergency hepatobiliary pathology and may contribute to the emergency management of hepatobiliary disease.

  10. Quantitative muscle ultrasonography in amyotrophic lateral sclerosis.

    NARCIS (Netherlands)

    Arts, I.M.P.; Rooij, F.G. van; Overeem, S.; Pillen, S.; Janssen, H.M.; Schelhaas, H.J.; Zwarts, M.J.

    2008-01-01

    In this study, we examined whether quantitative muscle ultrasonography can detect structural muscle changes in early-stage amyotrophic lateral sclerosis (ALS). Bilateral transverse scans were made of five muscles or muscle groups (sternocleidomastoid, biceps brachii/brachialis, forearm flexor group,

  11. Role of uterine artery doppler ultrasound in predicting preeclampsia primigravida

    International Nuclear Information System (INIS)

    Awan, F.; Ullah, H.

    2016-01-01

    Objective: To find the accuracy of uterine artery diastolic notching during the second trimester of pregnancy in predicting pre-eclampsia in primigravida patients. Study Design: Descriptive cross sectional study. Place and Duration of Study: Armed Forces Institute of Radiology and Imaging (AFIRI) Rawalpindi; six months duration from 30 Nov 2012 to 31 May 2013. Material and Methods: This study included 199 primigravida women with singleton pregnancy having diastolic notch in uterine arteries between 20 to 23 weeks of gestation. All patients were examined by both grey scale and doppler ultrasonography. Uterine arteries were evaluated with doppler near the point where they crossed the external iliac arteries. The patient was included in study if the presence of diastolic notch was demonstrated. Clinical follow up in gynae and obs department continued throughout the pregnancy to see if they developed preeclampsia. The data were recorded on a previously prepared proforma and analyzed with SPSS 21. Results: The accuracy of uterine artery doppler ultrasound in identifying women who later developed preeclampsia was 48.24 percent. The frequency of pre-eclampsia with bilateral notch was significantly high in the primigravid of younger age as compare to the primigravid of the older group (p=0.001). The difference in frequency of developing pre-eclampsia with bilateral notch when compared among 20 to 21 week gestational age and 22 to 23 weeks gestational age was statistically insignificant. Conclusion: Uterine artery diastolic notching between 20 and 23 weeks of gestation is an important risk factor for developing pre-eclampsia. This doppler parameter should, therefore, be included in the risk evaluation for gestational hypertension. (author)

  12. Comparison of power Doppler ultrasonographic findings of mesenteric lymphadenopathy between children with and without acute abdominal pain

    International Nuclear Information System (INIS)

    Hwangbo, Seal; Lim, Gye Yeon; Jang, Hye Suk; Choi, Byoung Gil; Lee, Jae Mun

    2002-01-01

    To evaluate power Doppler ultrasonographic findings of the enlarged mesenteric lymph nodes, and to compare between patients with and without acute abdominal pain. Thirty seven children with acute abdominal pain and thirty three asymptomatic children all with the enlarged mesenteric lymph nodes in whom power Doppler ultrasonography was performed were included in this study. The enlarged lymph nodes were evaluated for number, size, shape (ratio of long to short axis diameter: L/S ratio), distribution and hilar vascularity on gray scale ultrasonography while the flow pattern (3 types; nonvascular, hilar, peripheral type) of the vascularity was analyzed with power Doppler ultrasonography. The hilar pattern of vascular flow type was graded into I to III depending upon color signal. The comparison between symptomatic group and asymptomatic control group was analyzed with gray scale ultrasonography and power Doppler ultrasonography. The number of enlarged lymph nodes (n≥10) was greater in the symptomatic group (29/37, 78%) than in the control group (6/33, 18%) (p<0.01). The mean size of the largest lymph node between two groups was different with a statistical significance; the mean long diameter was 12.4 ± 3.1 mm (short diameter 5.8 ± 1.6 mm) in the symptomatic group and 11.2 ± 2.3 mm (4.5 ± 1.3 mm) in the control group (p<0.05). The mean L/S ratio of the largest one was 2.2 ± 0.6 in the symptomatic group and 2.7 ± 0.8 in the control group (p<0.05). Lymph nodes were detected in both right lower quadrant of the abdomen and periumblical region in 16 (43%) of the symptomatic group and 3 (9%) of the control group (p<0.01). On power Doppler ultrasonography, hilar type of vascularity was noted in 22 (67%) cases of the control group and all of symptomatic group. The prevalence of exuberant hilar flows (grade II/III) in the symptomatic group (28/37, 76%) was significantly higher than that of the control group (4/33,12%) (p<0.01). Enlarged mesenteric lymph nodes in the

  13. Vasoconstriction in horses caused by endophyte-infected tall fescue seed is detected with Doppler ultrasonography

    Science.gov (United States)

    The hypotheses that endophyte (Neotyphodium coenophialum)-infected tall fescue (TF) seed causes vasoconstriction in horses in vivo and that ground seed would cause more pronounced vasoconstriction than whole seed were tested. Ten horses each received 1 of 3 treatments: endophyte-free ground (E–G; n ...

  14. Embolic Signals during Routine Transcranial Doppler Ultrasonography in Aneurysmal Subarachnoid Hemorrhage

    Science.gov (United States)

    Paschoal, Fernando Mendes; de Almeida Lins Ronconi, Karla; de Lima Oliveira, Marcelo; Nogueira, Ricardo de Carvalho; Paschoal, Eric Homero Albuquerque; Teixeira, Manoel Jacobsen; Figueiredo, Eberval Gadelha; Bor-Seng-Shu, Edson

    2015-01-01

    Introduction. Cerebral emboli may occur in subarachnoid hemorrhage (SAH) and intracranial aneurysm surgery. Although embolic signs (ES) have been reported in SAH, their origin remains unclear. The aim of this study was to report the detection of ES during routine TCD monitoring in patients with aneurysmal SAH. Methods. A total of 105 patients with aneurysmal SAH were submitted to TCD evaluation. Patients were monitored almost daily (5 times per week). In each monitoring session, one experienced operator performed TCD to detect or assess vasospasm and ES in arteries of the Willis polygon. Results. Four patients out of a total of 105 patients with aneurysmal SAH were found to present spontaneous cerebral embolization during routine TCD monitoring. The average age of the 4 patients (mean ± standard deviation) was 59.5 ± 8.34 years (range 49–68 ys); female patients predominated representing 75% (3/4) of subjects. Conclusion. Although detection of ES was relatively rare in this study, rates of emboli occurrence may be higher under systematic monitoring. The detection of ES after SAH surgery reinforces the need to study the role of embolus in this condition and may be an indicator for prophylactic antithrombotic treatment. PMID:25893190

  15. Three-dimensional power Doppler ultrasonography in evaluation of adnexal masses

    Directory of Open Access Journals (Sweden)

    Ahmed M. Abbas

    2017-12-01

    The introduction of 3DPD has opened the possibility to characterize microvasculature of the adnexal masses and objectively assess tumor vascularization. 3DPD allows also an objective measurement of vascularity of a given region of interest by estimating 3 vascular indices (vascularization index [VI], flow index [FI], and vascularization-flow index [VFI] within such region. The aim of this review article is to evaluate the role of 3DPD in the assessment of adnexal masses vascularity, its ability to discriminate benign masses from malignant ones.

  16. Ultrasonography of the biliary tract - up to date. The importance of correlation between imaging methods and patients' signs and symptoms.

    Science.gov (United States)

    Badea, Radu; Zaro, Răzvan; Tanțău, Marcel; Chiorean, Liliana

    2015-09-01

    Ultrasonography is generally accepted and performed as a first choice imaging technique in patients with jaundice. The method allows the discrimination between cholestatic and mechanical jaundice. The existing procedures are multiple: gray scale, Doppler, i.v. contrast enhancement, elastography, tridimensional ultrasonography, each of these with different contribution to the positive and differential diagnosis regarding the nature of the jaundice. The final diagnosis is a multimodal one and the efficiency is dependent on the level of the available technology, the examiner's experience, the degree and modality of integration of the data within the clinical context, as well as on the portfolio of available imaging procedures. This review shows the main ultrasonographic methods consecrated in the evaluation of the biliary tree. It also underlines the integrated character of the procedures, as well as the necessity to correlate with other imaging methods and the clinical situation.

  17. [Parenchymal complications of the transplanted kidney: the role of color-Doppler imaging].

    Science.gov (United States)

    Granata, Antonio; Clementi, Silvia; Clementi, Anna; Di Pietro, Fabio; Scarfia, Viviana R; Insalaco, Monica; Aucella, Filippo; Prencipe, Michele; Fiorini, Fulvio; Sicurezza, Elvia

    2012-01-01

    Kidney transplantation is the treatment of choice for end-stage renal disease, given the better quality of life of transplanted patients when compared to patients on maintenance dialysis. In spite of surgical improvements and new immunosuppressive regimens, part of the transplanted grafts still develop chronic dysfunction. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of vascular and surgical complications of the transplanted kidney, its role is not fully understood in case of parenchymal complications of the graft. The specificity of Doppler ultrasound is low both in case of acute complications such as acute tubular necrosis, drug toxicity and acute rejection, and in case of chronic conditions such as chronic allograft nephropathy. Single determinations of resistance indices present low diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including tissue pulsatility index, maximal fractional area and contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of parenchymal complications of the transplanted kidney.

  18. Radiofrequency ablation of liver cancer: early evaluation of therapeutic response with contrast-enhanced ultrasonography

    International Nuclear Information System (INIS)

    Choi, Dong Gil; Lim, Hyo K.; Lee, Won Jae; Kim, Seung Hoon; Kim, Min Ju; Kim, Seung Kwon; Jang, Kyung Mi; Lee, Ji Yeon; Lim, Jae Hoon

    2004-01-01

    The early assessment of the therapeutic response after percutaneous radiofrequency (RF) ablation is important, in order to correctly decide whether further treatment is necessary. The residual unablated tumor is usually depicted on contrast-enhanced multiphase helical computed tomography (CT) as a focal enhancing structure during the arterial and portal venous phases. Contrast-enhanced color Doppler and power Doppler ultrasonography (US) have also been used to detect residual tumors. Contrast-enhanced gray-scale US, using a harmonic technology which has recently been introduced, allows for the detection of residual tumors after ablation, without any of the blooming or motion artifacts usually seen on contrast-enhanced color or power Doppler US. Based on our experience and reports in the literature, we consider that contrast-enhanced gray-scale harmonic US constitutes a reliable alternative to contrast-enhanced multiphase CT for the early evaluation of the therapeutic response to RF ablation for liver cancer. This technique was also useful in targeting any residual unablated tumors encountered during additional ablation

  19. Transversal Doppler-Fizeau effect

    International Nuclear Information System (INIS)

    Subacius, E.

    1981-01-01

    The relativistic calculation of the Doppler-Fizeau effect foresees a second grade redshift due to the proper time dilation of a moving object. The relevance of this relativistic effect on astrophysical observation is discussed, herein. (Auhor) [pt

  20. Dual-Doppler Feasibility Study

    Science.gov (United States)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  1. Economic analysis of bedside ultrasonography (US) implementation in an Internal Medicine department.

    Science.gov (United States)

    Testa, Americo; Francesconi, Andrea; Giannuzzi, Rosangela; Berardi, Silvia; Sbraccia, Paolo

    2015-12-01

    The economic crisis, the growing healthcare demand, and Defensive Medicine wastefulness, strongly recommend the restructuring of the entire medical network. New health technology, such as bedside ultrasonography, might successfully integrate the clinical approach optimizing the use of limited resources, especially in a person-oriented vision of medicine. Bedside ultrasonography is a safe and reliable technique, with worldwide expanding employment in various clinical settings, being considered as "the stethoscope of the 21st century". However, at present, bedside ultrasonography lacks economic analysis. We performed a Cost-Benefit Analysis "ex ante", with a break-even point computing, of bedside ultrasonography implementation in an Internal Medicine department in the mid-term. Number and kind estimation of bedside ultrasonographic studies were obtained by a retrospective study, whose data results were applied to the next 3-year period (foresight study). All 1980 foreseen bedside examinations, with prevailing multiorgan ultrasonographic studies, were considered to calculate direct and indirect costs, while specific and generic revenues were considered only after the first semester. Physician professional training, equipment purchase and working time represented the main fixed and variable cost items. DRG increase/appropriateness, hospitalization stay shortening and reduction of traditional ultrasonography examination requests mainly impacted on calculated revenues. The break-even point, i.e. the volume of activity at which revenues exactly equal total incurred costs, was calculated to be 734 US examinations, corresponding to € 81,998 and the time considered necessary to reach it resulting 406 days. Our economic analysis clearly shows that bedside ultrasonography implementation in clinical daily management of an Internal Medicine department can produce consistent savings, or economic profit according to managerial choices (i.e., considering public or private targets

  2. Glare Spot Phase Doppler Anemometry

    OpenAIRE

    Hespel, Camille; Ren, Kuan Fang; Gréhan, Gérard; Onofri, Fabrice

    2006-01-01

    International audience; The Phase Doppler anemometry has been developed to measure simultaneously the velocity and the size of droplets. The measurement of the refractive index is also necessary since it depends on the temperature and the composition of the particle and its measurement permits both to increase the quality of the diameter measurement and to obtain information on the temperature and/or the composition of the droplets. In this paper, we introduce a Glare Spot Phase Doppler Anemo...

  3. Guide book mammary glands ultrasonography. A textbook according to the DEGUM and KBV guidelines. 3. upd. ed.

    International Nuclear Information System (INIS)

    Madjar, Helmut

    2012-01-01

    The text book on the ultrasonography of mammary glands is based on the concept of a three-step course system. The large amount of pathological indications is supposed to communicate knowledge that is required to find an adequate diagnosis based on ultrasonsographic imaging. The book includes the following chapters: Basics of ultrasonic mammography; diagnostic techniques; sono-anatomy of breast and axilla; standardized diagnosis; mastopathy; cysts and intracystic tumors; prostheses; abscesses; benign solid tumors; scars; carcinomas; lymph nodes; interventional sonography; preoperative staging; preventive diagnostics; aftercare, relapses; 3D-sonography, panorama-scan, real-time compound-scan; CARI technique; Doppler sonography; elastography; examination questions on ultrasonic mammography.

  4. Effects of respiratory manoeuvres on hepatic vein Doppler waveform and flow velocities in a healthy population

    International Nuclear Information System (INIS)

    Altinkaya, Naime; Koc, Zafer; Ulusan, Serife; Demir, Senay; Gurel, Kamil

    2011-01-01

    Objective: This study was performed to determine the variations in Doppler waveforms and flow velocity during respiratory manoeuvres in healthy individuals with no liver disease. Materials and methods: In total, 100 individuals (75 women and 25 men) without known cardiac or liver disease were examined prospectively with duplex Doppler ultrasonography (US). We recorded the Doppler waveforms and peak systolic velocities (V max ) of the middle hepatic vein during normal respiration, during breath-holding after quiet expiration and also during deep inspiration. Doppler waveforms are categorised as triphasic, biphasic or monophasic. Results: During normal respiration, hepatic venous waveforms were triphasic in 93% of subjects, monophasic in 6% and biphasic in 1%. During breath-holding after quiet expiration, the percentages were 91%, 6% and 3%, respectively. During deep inspiration, they were 80%, 18% and 2%, respectively. Although significant differences were noted between rates during deep inspiration and normal respiration, they were quite similar during normal respiration and breath-holding after quiet expiration (P max were significantly higher during normal respiration compared to quiet expiration and during quiet expiration compared to deep inspiration (P < 0.05). Conclusion: The velocities and waveforms of hepatic veins varied during respiratory manoeuvres. The status of respiration must be taken into consideration whilst examining the hepatic vein waveforms and velocities with duplex Doppler US.

  5. Ultrasonography in Early Diagnosis of Heterotopic Ossification

    Directory of Open Access Journals (Sweden)

    Shan-Hui Lin

    2014-12-01

    Full Text Available We report here the case of a 32-year-old man with a history of traumatic brain injury who presented with swelling of his right thigh. Soft tissue ultrasonography performed 3 days after the onset of symptoms showed a heterogeneous hyperechoic lesion with the formation of cysts and hypervascularity in the right iliopsoas abutting the surface of the femoral bone. This became a diffuse echogenic plaque with a posterior acoustic shadowing 12 days later. A diagnosis of heterotopic ossification was made on the basis of the presence of typical ultrasonographic findings and was confirmed by pathology. We emphasize that an early diagnosis of heterotopic ossification can be made with ultrasonography and can lead to early treatment.

  6. Vascular access: the impact of ultrasonography

    Science.gov (United States)

    de Almeida, Carlos Eduardo Saldanha

    2016-01-01

    ABSTRACT Vascular punctures are often necessary in critically ill patients. They are secure, but not free of complications. Ultrasonography enhances safety of the procedure by decreasing puncture attempts, complications and costs. This study reviews important publications and the puncture technique using ultrasound, bringing part of the experience of the intensive care unit of the Hospital Israelita Albert Einstein, São Paulo (SP), Brazil, and discussing issues that should be considered in future studies. PMID:28076607

  7. Differential diagnosis of calf pain by ultrasonography

    Directory of Open Access Journals (Sweden)

    Luciano Augusto Botter

    2008-03-01

    Full Text Available This paper aims to evaluate the recent and numerous applications of ultrasonography in the differential diagnosis of conditions that affect the popliteal fossa and lower limbs, resulting in calf pain. Popliteal cysts and their ruptures, aneurysms, hematomas, cellulitis, abscesses, soft tissue tumors and other fluid collections are easily identified by this technique. Moreover, post-trauma and inflammatory conditions affecting muscles and tendons, muscle necrosis, deep venous thrombosis and superficial thrombophlebitis are very well demonstrated by the ultrasonographic screening.

  8. Real time ultrasonography in obstructive jaundice

    International Nuclear Information System (INIS)

    Cho, Kyung Sik; Kim, Ho Kyun; Sung, Nak Kwan; Kim, Soon Yong

    1982-01-01

    Ultrasonography is a predominantly accurate, relatively simple unique diagnostic method of obstructive jaundice. The ultrasonographic findings of obstructive jaundice are dilated intra- and extrahepatic duct with intraluminal hyper reflective echo or mass in and/ or around the bile duct. The superiority of high resolution real time ultrasonography for the diagnosis of obstructive jaundice is bases on the easy detectability of extra- and intrahepatic bile ducts by its multiple sectional images in a short time, the flexibility of probe and small crystal size. Author evaluated real time sonographic findings 46 obstructive jaundice patients confirmed by surgery or radiographical examinations. The results were: 1. Diameter of extrahepatic duct in obstructive jaundice were varied from normal to 4.0 Cm, mostly 8 to 10 mm in diameter (26%). Degree of dilatation of biliary duct appeared more prominent in cancer patients than other causes of obstruction. 2. The site of obstruction was detected in 85% (39/46) and its common site was common bile duct in 63% (29/46). 3. The diagnostic accuracy of choledocholithiasis and cancer was 82% (22/27) and 44% (4/9), respectively. Diagnostic accuracy of the real time ultrasonography in obstructive jaundice was over all 75% (34/46)

  9. THE DOPPLER ECHOGRAPHY – FROM GREEK MYTHOLOGY TO MODERN CARDIOLOGY

    Directory of Open Access Journals (Sweden)

    Diana DĂNIŞOR

    2016-10-01

    Full Text Available The following pages shall demonstrate how the nature of things is made evident through the science of naming, the structure of designation. Through this extensive analysis, I aim at establishing the connection between Greek mythology and modern cardiology by exploring the origin of the word echography and its modern counterpart the Doppler echography.

  10. Cost-effectiveness analysis of ultrasonography screening for nonalcoholic fatty liver disease in metabolic syndrome patients

    Science.gov (United States)

    Phisalprapa, Pochamana; Supakankunti, Siripen; Charatcharoenwitthaya, Phunchai; Apisarnthanarak, Piyaporn; Charoensak, Aphinya; Washirasaksiri, Chaiwat; Srivanichakorn, Weerachai; Chaiyakunapruk, Nathorn

    2017-01-01

    Abstract Background: Nonalcoholic fatty liver disease (NAFLD) can be diagnosed early by noninvasive ultrasonography; however, the cost-effectiveness of ultrasonography screening with intensive weight reduction program in metabolic syndrome patients is not clear. This study aims to estimate economic and clinical outcomes of ultrasonography in Thailand. Methods: Cost-effectiveness analysis used decision tree and Markov models to estimate lifetime costs and health benefits from societal perspective, based on a cohort of 509 metabolic syndrome patients in Thailand. Data were obtained from published literatures and Thai database. Results were reported as incremental cost-effectiveness ratios (ICERs) in 2014 US dollars (USD) per quality-adjusted life year (QALY) gained with discount rate of 3%. Sensitivity analyses were performed to assess the influence of parameter uncertainty on the results. Results: The ICER of ultrasonography screening of 50-year-old metabolic syndrome patients with intensive weight reduction program was 958 USD/QALY gained when compared with no screening. The probability of being cost-effective was 67% using willingness-to-pay threshold in Thailand (4848 USD/QALY gained). Screening before 45 years was cost saving while screening at 45 to 64 years was cost-effective. Conclusions: For patients with metabolic syndromes, ultrasonography screening for NAFLD with intensive weight reduction program is a cost-effective program in Thailand. Study can be used as part of evidence-informed decision making. Translational Impacts: Findings could contribute to changes of NAFLD diagnosis practice in settings where economic evidence is used as part of decision-making process. Furthermore, study design, model structure, and input parameters could also be used for future research addressing similar questions. PMID:28445256

  11. Evident?

    DEFF Research Database (Denmark)

    Plant, Peter

    2012-01-01

    Quality assurance and evidence in career guidance in Europe are often seen as self-evident approaches, but particular interests lie behind......Quality assurance and evidence in career guidance in Europe are often seen as self-evident approaches, but particular interests lie behind...

  12. Placental mesenchymal dysplasia and intrauterine fetal growth restriction with doppler velocimetry alterations - a case report

    Directory of Open Access Journals (Sweden)

    Paula Vendruscolo Tozatti

    2014-06-01

    Full Text Available Placental mesenchymal dysplasia (PMD is a rare placental abnormality. We report a case of PMD associated with intrauterine growth restriction (IUGR, which was diagnosed by an ultrasound scan during the second trimester of pregnancy. A 36-year-old primiparous woman with signs of placental chorioangioma was referred to our hospital at the 23th gestational week. An ultrasonography revealed a small-for-gestational-age fetus with a large multicystic placenta. A serial Doppler sonographic assessment of umbilical and uterine artery blood flow showed a compromised fetus. A female, small-for-gestational-age baby was delivered by c-section at 28 weeks, and PMD was histopathologically confirmed.

  13. Ultrasonography of occipital arteries to diagnose giant cell arteritis: a case series and literature review.

    Science.gov (United States)

    Pinnell, Jonathan; Tiivas, Carl; Perkins, Phillip; Blake, Tim; Saravana, Shanmugam; Dubey, Shirish

    2018-02-01

    We describe four cases of giant cell arteritis (GCA) that presented with occipital headache in the last 6 months. Typical ultrasound features of GCA were found in the occipital arteries which helped to confirm the diagnosis. One patient had already suffered significant visual loss by the time the diagnosis was made, reflecting the similarity in prognosis to the more typical GCA patients. These cases prompted a review of the literature to evaluate the evidence regarding the use of occipital artery ultrasonography in the investigation of GCA. We searched PubMed, Google Scholar and Web of Science and identified 17 papers but only four of these were relevant studies. The studies available show that typical features of GCA can be detected in the occipital arteries using ultrasonography. They also suggest that ultrasonography can detect changes in the occipital arteries when temporal arteries are not involved. However, occipital artery abnormalities were less common than temporal artery abnormalities in GCA. We advocate maintaining a high index of suspicion for GCA in patients presenting with atypical features, such as occipital headache. Ultrasonography has a vital role to play in the diagnosis of these patients. We recommend priority imaging of the affected area to facilitate prompt and accurate diagnosis of GCA, especially when atypical vessels are involved.

  14. Doppler ultrasound imaging techniques for assessment of synovial inflammation

    Directory of Open Access Journals (Sweden)

    Filippucci E

    2013-09-01

    Full Text Available Emilio Filippucci,1 Fausto Salaffi,1 Marina Carotti,2 Walter Grassi1 1Rheumatology Department, Polytechnic University of the Marche, Ancona, Italy; 2Department of Radiology, Polytechnic University of the Marche, Ancona, Italy Abstract: Ultrasound is an evolving technique, and the rapid progress made in ultrasound technology over the past ten years has dramatically increased its range of applications in rheumatology. One of the most exciting advances is the use of Doppler ultrasound imaging in the assessment of blood flow abnormalities at the synovial tissue level in patients with chronic inflammatory arthritis. This review describes the Doppler techniques available and their main applications in patients with inflammatory arthritis, discusses the evidence supporting their use, and outlines the latest advances in hardware and software. Spectral, color, and power Doppler allow sensitive assessment of vascular abnormalities at the synovial tissue level. Use of contrast agents enhances visualization of the small synovial vessels using color or power Doppler ultrasound and allows for accurate characterization of the rheumatoid pannus. Doppler techniques represent a unique method for assessment of synovial inflammation, showing blood flow characteristics in real time. They are safe, noninvasive, cost-effective, and have high sensitivity in revealing and monitoring synovitis. However, several questions still need to be answered. In the near future, the Doppler techniques described here, together with upcoming hardware and software facilities, will be investigated further and a consensus will be reached on their feasibility and appropriate use in daily rheumatologic practice. Keywords: power and color Doppler techniques, ultrasound, contrast media, synovitis, rheumatoid arthritis

  15. Applications of ultrasonography in the diagnosis of parenchymal kidney disease in cats: 24 cases (1981-1986)

    International Nuclear Information System (INIS)

    Walter, P.A.; Johnston, G.R.; Feeney, D.A.; O'Brien, T.D.

    1988-01-01

    Renal sonograms from 24 cats with confirmed parenchymal kidney disease and from 1 cat with radiographic and palpable evidence of renal enlargement (but without identifiable histologic abnormalities) were evaluated to describe the ultrasonographic appearance of feline renal diseases and to determine the role of ultrasonographic examination in the clinical evaluation of these cases. In all cats with radiographic evidence of abnormal renal size or contour and when poor intraabdominal radiographic contrast precluded visualization of the kidneys, ultrasonography provided complementary information pertaining to location (cortical/medullary), extent, and distribution (focal/multifocal/diffuse) of disease. Ultrasonography also characterized these lesions as cystic (cavitating) or solid. The echo patterns were most specific for renal cysts. Infiltrative diseases did not have consistent patterns. Multifocal hypoechoic nodules, diffuse cortical hyper-echogenicity, and normal-appearing parenchyma were identified. In these instances, however, ultrasonography did define the extent of disease and narrowed the spectrum of differential considerations

  16. Usefulness of ultrasonography in follow-up evaluation after Ilizarov procedure : comparison with plain radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Hoon; Jee, Sung Woo; Lee, Ho Won; Lee, Sung Moon; Kim, Jung Sik; Kim, Hong; Song, Kwang Soon; Woo, Sung Ku [Keimyung University, Taegu (Korea, Republic of). School of Medicine; Cho, Kil Ho [Yeungnam Univ., Taegu (Korea, Republic of). School of Medicine

    1998-06-01

    The purpose of this study is to compare the usefulness of ultrasonography in follow up evaluation after the Ilizarov procedure with that of plain radiography. We analyzed ultrasound findings in twelve patients who had undergone the Ilizarov procedure, and retrospectively compared the results with the findings of plain radiography. The procedure was performed due to post-traumatic limb deformity or non-union (nine of twelve patients), congenital pseudoarthrosis (one case), sequelae of poliomyelitis (one case), and short stature (one case). The patients` mean age was 29 years; eleven of twelve were male. Ten of twelve procedures were performed on the tibia and two on the femur. After 7-10 days, distraction was initiated at a rate of 0.25 mm four times a day. Ultrasonography was performed with a 5-10 MHz linear or convex transducer; new bone formation was defined as dotted or linear echogenic foci within a hypoechoic distraction gap. Initial ultrasonographic examination was performed 2-4 weeks after distraction, and the results were compared with those of plain radiography. Color doppler imaging was performed in three cases. After the Ilizarov bone lengthening procedure, ultrasound appears to be useful for follow-up examination. New bone formation, as well as complications, can be detected earlier; it can indicate whether ultrasound-guided interventional procedure is required, and if combined with color doppler study, is able to detect the periosteal blood supply. Further evaluation of the clinical significance of preserved periosteal blood supply seems however, to be needed. (author). 18 refs., 4 figs.

  17. Usefulness of ultrasonography in follow-up evaluation after Ilizarov procedure : comparison with plain radiography

    International Nuclear Information System (INIS)

    Lee, Jong Hoon; Jee, Sung Woo; Lee, Ho Won; Lee, Sung Moon; Kim, Jung Sik; Kim, Hong; Song, Kwang Soon; Woo, Sung Ku; Cho, Kil Ho

    1998-01-01

    The purpose of this study is to compare the usefulness of ultrasonography in follow up evaluation after the Ilizarov procedure with that of plain radiography. We analyzed ultrasound findings in twelve patients who had undergone the Ilizarov procedure, and retrospectively compared the results with the findings of plain radiography. The procedure was performed due to post-traumatic limb deformity or non-union (nine of twelve patients), congenital pseudoarthrosis (one case), sequelae of poliomyelitis (one case), and short stature (one case). The patients' mean age was 29 years; eleven of twelve were male. Ten of twelve procedures were performed on the tibia and two on the femur. After 7-10 days, distraction was initiated at a rate of 0.25 mm four times a day. Ultrasonography was performed with a 5-10 MHz linear or convex transducer; new bone formation was defined as dotted or linear echogenic foci within a hypoechoic distraction gap. Initial ultrasonographic examination was performed 2-4 weeks after distraction, and the results were compared with those of plain radiography. Color doppler imaging was performed in three cases. After the Ilizarov bone lengthening procedure, ultrasound appears to be useful for follow-up examination. New bone formation, as well as complications, can be detected earlier; it can indicate whether ultrasound-guided interventional procedure is required, and if combined with color doppler study, is able to detect the periosteal blood supply. Further evaluation of the clinical significance of preserved periosteal blood supply seems however, to be needed. (author). 18 refs., 4 figs

  18. Severe portal hypertension in cirrhosis: evaluation of perfusion parameters with contrast-enhanced ultrasonography.

    Directory of Open Access Journals (Sweden)

    Woo Kyoung Jeong

    Full Text Available To investigate the role of contrast-enhanced ultrasonography (CEUS and Doppler ultrasonography (DUS in the diagnosis of severe portal hypertension (PH in patients with liver cirrhosis (LC.Patients with PH scheduled to receive hepatic venous pressure gradient (HVPG measurement were recruited for this study. Hepatic DUS and CEUS were performed successively. Several Doppler and CEUS parameters were explored for correlation with HVPG values and their association with severe PH (≥ 12 mmHg of HVPG. Comparison of the parameters between the severe and non-severe PH groups and their correlation with HVPG values was evaluated. A receiver operating characteristic (ROC curve analysis was also performed to investigate the performance in order to diagnose severe PH.Fifty-three consecutive patients were enrolled in this study. Among them, 43 patients did not have significant ascites. Compared with the non-severe PH group, portal venous velocity and intrahepatic transit time (ITT were significantly reduced in the severe PH group (all p<0.05. Difference between inspiratory and expiratory hepatic venous damping indices (ΔHVDI, hepatic venous arrival time (HVAT and ITT moderately correlated with HVPG (r = -0.358, -0.338, and -0.613, respectively. Areas under the curves for severe PH were 0.94 of ITT and 0.72 of HVAT, respectively (all p<0.05. ITT under 6 seconds indicated severe PH with a sensitivity of 92% and a specificity of 89%.Hepatic CEUS may be more useful in estimating the HVPG value and determining the presence of severe PH compared to DUS, and ITT was the most accurate parameter to diagnose severe PH.

  19. Doppler echocardiography in pediatric cardiology

    International Nuclear Information System (INIS)

    Allen, H.D.; Marx, G.R.

    1986-01-01

    Congenital heart disease encompasses abnormalities in cardiac development which generally have in common either valve stenoses or connections between chambers or great vessels. Usually, abnormalities of intracardiac anatomy, and often, abnormalities of great vessel anatomy, can be unraveled by two-dimensional echocardiography. However, echocardiography offers little information regarding flow characteristics in the various congenital lesions. Addition of the Doppler principle, particularly when combined with the two-dimensional examination, can characterize the source of a flow disturbance, quantify gradients across a site of obstruction, and quantify flow volume across sites where flow is nonturbulent. These features make Doppler echocardiography unique for noninvasive accurate evaluation of children and adults with various forms of congenital heart disease. In this report, the authors discuss some of the present uses of Doppler echocardiography in congenital heart disease. Application of this technique requires greater understanding of certain physics principles than does routine echocardiography

  20. Color doppler flow imaging in evaluation of uterine arterial embolization of leiomyoma with KMG

    International Nuclear Information System (INIS)

    Li Furong; Guo Yunhuai; Liu Lifang; Liu Jianhua; Guo Yunhuai

    2006-01-01

    Objective: To explore the effectiveness of a new kind of embolization agent-sodium alginate(KMG), and to evaluate the clinical value of 2D color Doppler ultrasound in assessing the therapeutic effect of uterine arterial embolization (UAE) in leiomyomas. Methods: Forty nine patients with symptomatic leiomyomas were undertaken UAE with KMG for the treatment. Sonography was performed at 3-7 days before and, 1, 3, 6 months after UAE with 2D color Doppler for evaluating the 2D echograms and hemodynamics. Results: Forty nine leiomyomas were studied after UAE, showing a marked reduction in the size (35%-90%). No blood flow was demonstrated in the leiomyomas either 3-7 days or 1 month or 3 months after the procedure. The reappearance of blood flow could be seen in only one case. Conclusion: KMG is an efficient embolization agent for the treatment of symptomatic leiomyomas with UAE, and ultrasonography is a useful tool to assess the effectiveness. (authors)

  1. Computed tomography of hepatocellular carcinoma. Comparison with scintigraphy and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Kuniyuki; Nakata, Hajime; Honda, Hiroshi [University of Occupational and Environmental Health, Kitakyushu, Fukuoka (Japan)

    1983-09-01

    The detectability of hepatocellular carcinoma by computed tomography (CT) was evaluated on 76 cases. The detectability by plain CT was 93% with only slight improvement following a drip infusion of contrast medium. A comparison of scintigraphy, ultrasonography, and CT was also done on 63 cases. From the standpoint of the overall detectability of the tumor, CT was as good as ultrasonography or scintigraphy. Several cases were positive only on either CT or ultrasonography but no case was positive on scintigraphy alone. We believe that the combination of CT and ultrasonography is the most reliable as the screening method.

  2. Acute intrascrotal pathology in childhood: color Doppler study

    International Nuclear Information System (INIS)

    Cinta Sanguesa, C.; Muro, D.; Cortina, H.; Moreno, A.

    1997-01-01

    To asses the utility of color Doppler ultrasound in the study of acute intrascrotal pathology in childhood. Seventy-five boys with evidence of an acute intrascrotal abnormality were studied by means of color Doppler ultrasound. A 7.5 MHz linear transducer was used. The most common findings was inflammatory disease (60%) which was indicated by the presence of hyperemia in color Doppler. Of the nine boys with testicular torsion (12%) two presented extravaginal torsion, with a complete absence of intratesticular vascularization. Intravaginal torsion was observed in seven patients, six of whom presented reduced vascularization in the abnormal testicle with respect to the healthy testicle. There was one false negative in which testicular vascularization was normal but 360 degree centigree torsion was found at surgery. In addition, there were seven cases of hydatid torsion (9.33%), four of idiopathic scrotal swelling (5.3%). two cases of intermittent torsion (2.6%) and one case of Shcolein-Henoch purpura (1.3%). The ultrasound findings were completely nornal in seven boys. Color Doppler is a rapid, noninvasive method for assessing testicular blood flow. The elevated sensitivity and specificity (85.7 and 100%, respectively, in our series) for testicular torsion make Doppler ultrasound a highly reliable method for the study of this disorder. (Author) 18 refs

  3. Normal Doppler velocimetry of renal vasculature in Persian cats.

    Science.gov (United States)

    Carvalho, Cibele F; Chammas, Maria C

    2011-06-01

    Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n=50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17±13.46 cm/s and 0.38±0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15±0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17±9.40 cm/s and 0.54±0.07. The RA had a mean ESA of 1.12±1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828±0.296. The IA showed PSV and RI values of 32.16±9.33 cm/s and 0.52±0.06, respectively. The mean ESA of all IAs was 0.73±0.61 m/s(2). The calculated upper limit of the reference value was 2.0m

  4. APPLICATION OF LAPAROSCOPIC ULTRASONOGRAPHY IN ADNEXAL OPERATIONS

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Objective:To explore the clinical value on application of laparoscopic ultrasonography (Lap US) in the adnexal operation. Methods:Eleven patients including 7 cases of tubal pregnancy, 3 cases of teratoma of ovary and 1 case of endometrial cyst of ovary were examined by LapUS, then operated with laparoscopy.Results:The results showed that the modality presented is a big progress over the traditional operative management for adnexal diseas. Conclusions:It is a good approach for micro-surgery in the adnexal operation by laparoscopy.

  5. Optically neuronavigated ultrasonography in an intraoperative magnetic resonance imaging environment.

    Science.gov (United States)

    Katisko, Jani P A; Koivukangas, John P

    2007-04-01

    To develop a clinically useful method that shows the corresponding planes of intraoperative two-dimensional ultrasonography and intraoperative magnetic resonance imaging (MRI) scans determined with an optical neuronavigator from an intraoperative three-dimensional MRI scan data set, and to determine the qualitative and the quantitative spatial correspondence between the ultrasonography and MRI scans. An ultrasound probe was interlinked with an ergonomic and MRI scan-compatible ultrasonography probe tracker to the optical neuronavigator used in a low-field intraoperative MRI scan environment for brain surgery. Spatial correspondence measurements were performed using a custom-made ultrasonography/MRI scan phantom. In this work, instruments to combine intraoperatively collected ultrasonography and MRI scan data with an optical localization method in a magnetic environment were developed. The ultrasonography transducer tracker played an important role. Furthermore, a phantom for ultrasonography and MRI scanning was produced. This is the first report, to our knowledge, regarding the possibility of combining the two most important intraoperative imaging modalities used in neurosurgery, ultrasonography and MRI scanning, to guide brain tumor surgery. The method was feasible and, as shown in an illustrative surgical case, has direct clinical impact on image-guided brain surgery. The spatial deviation between the ultrasonography and the MRI scans was, on average, 1.90 +/- 1.30 mm at depths of 0 to 120 mm from the ultrasonography probe. The overall result of this work is a unique method to guide the neurosurgical operation with neuronavigated ultrasonography imaging in an intraoperative MRI scanning environment. The relevance of the method is emphasized in minimally invasive neurosurgery.

  6. Doppler broadening of cross sections

    International Nuclear Information System (INIS)

    Buckler, P.A.C.; Pull, I.C.

    1962-12-01

    Expressions for temperature dependent cross-sections in terms of resonance parameters are obtained, involving generalisations of the conventional Doppler functions, ψ and φ. Descriptions of Fortran sub-routines, which calculate broadened cross-sections in accordance with the derived formulae, are included. (author)

  7. Anomalous Doppler effects in bulk phononic crystal

    International Nuclear Information System (INIS)

    Cai Feiyan; He Zhaojian; Zhang Anqi; Ding Yiqun; Liu Zhengyou

    2010-01-01

    Doppler effects in simple cubic phononic crystal are studied theoretically and numerically. In addition to observing Doppler shifts from a moving source's frequencies inside the gap, we find that Doppler shifts can be multi-order, anisotropic, and the dominant order of shift depends on the band index that the source's frequency is in.

  8. Hepatic vein Doppler waveform in patients with diffuse fatty infiltration of the liver

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Yildirim, Tulin; Torun, Dilek; Tercan, Fahri; Kizilkilic, Osman; Niron, E. Alp

    2005-01-01

    Objective: To determine the incidence of abnormal hepatic vein Doppler waveform in patients with diffuse fatty infiltration of the liver (FIL). Materials and methods: In this prospective study, 40 patients with diffuse FIL and 50 normal healthy adults who served as control group underwent hepatic vein (HV) Doppler ultrasonography. The patients with the diagnosis of FIL were 23 men (57.5%) and 17 women aged 30-62 years (mean age ± S.D., 42 ± 12 years). Subjects in the control group were 27 men (54%) and 23 women aged 34-65 years (mean age ± S.D., 45 ± 14 years). The diagnosis of FIL was confirmed with computed tomography density measurements. The waveforms of HV were classified into three groups: regular triphasic waveform, biphasic waveform without a reverse flow, and monophasic or flat waveform. Etiological factors for FIL were diabetes mellitus (DM), hyperlipidemia and obesity (body mass index > 25). Serum lipid profile was obtained from all the patients with FIL. Results: Seventeen of the 40 patients (43%) with FIL had an abnormal HV Doppler waveform, whereas only one of the 50 (2%) healthy subjects had an abnormal waveform. The difference in the distribution of normal Doppler waveform pattern between the patients and the control group was significant (P 0.05). There was not any correlation between the degree of fat infiltration and the hepatic vein waveform pattern (P = 0.60). Conclusion: Patients with fatty liver has a high rate of an abnormal hepatic vein Doppler waveform pattern which can be biphasic or monophasic. We could not find a relation between the etiological factors for FIL and the occurrence of an abnormal HV Doppler waveform

  9. Fresh look at the doppler changes in pregnancies with placental-based complications

    Directory of Open Access Journals (Sweden)

    S Dikshit

    2011-01-01

    Full Text Available Placental-based complications of pregnancy can be classified as acute and chronic. An example of acute placental complication is abruptio placenta. The chronic placental complications include pregnancy induced hypertension (PIH and idiopathic Intrauterine growth restriction (IUGR. The fetus is at risk for perinatal complications in both acute and chronic conditions. Here we take a look at the natural history of the Doppler parameters in chronic conditions. The techniques used for assessing the fetal well-being include, clinical methods, biophysical tests, conventional ultrasonography, and fetal Doppler studies. Arterial Doppler studies are used to assess the well-being of the fetus and to determine the timing of delivery. However, arterial Dopplers predict only the subset of fetuses at risk of having perinatal complications. Venous Dopplers have been used to improve upon the prognostication. However, by the time the commonly used venous Doppler signs, that is, ′A′ wave reversal in ductus venosus (DV is present, the fetus is likely to be already compromised. The fetus tries to adapt to the environment of deprivation by making a series of changes in the umbilical artery circulation, cerebral circulation, and hepatic circulation. As a result of these adaptations, the fetus overcomes the state of chronic hypoxia. This article takes a look at these changes and also the effect of these adaptations. It is suggested that serial comparisons of the venous flow characteristics of the DV and inferior vena cava (IVC can provide an early indication of the impending decompensation and can be used to predict the time the delivery.

  10. Anatomy and ultrasonography of the normal kidney in brown lemurs: Eulemur fulvus.

    Science.gov (United States)

    Raharison, Fidiniaina; Mogicato, Giovanni; Sautet, Jean

    2009-08-01

    The purpose of this study is to describe the anatomy and obtain echographic measurements of normal kidneys in brown lemurs (Eulemur fulvus). The anatomical findings show that brown lemur kidneys are comparable to those of rats except for an elongated papilla. The kidneys of 16 (7 females and 9 males) lemurs were examined with two-dimensional and power Doppler ultrasonography under general anesthesia. Morphometrically, the left and right kidney surface areas are comparable (3.29 and 3.51 cm(2)). Kidney area has a significant linear correlation with body weight. Echo-Doppler findings show that the mean renal arterial blood flow speeds for the left and right kidneys are comparable (0.70 and 0.73 m/s). However, flow speed is higher in the male (0.79 m/s) than in the female (0.60 m/s). The renal arterial diameters are between 1.0 and 1.8 mm. The fact that anesthesia can have hemodynamic effects on renal vasculature should be taken into consideration when assessing these echographic results.

  11. Diagnostic value of ultrasonography in evaluation and management ...

    African Journals Online (AJOL)

    Results: Common causes of acute abdominal emergencies in pediatric patients as noted on ultrasonography included nonspecifi c pain (28%), abdominal abscess (21%), acute appendicitis (7%) and intussusception (7%). Ultrasonography was diagnostic in 45.2% cases and supportive in 12.3% of the cases. As for as the fi ...

  12. Nuclear medicine and ultrasonography in the acute cholecystitis diagnosis

    International Nuclear Information System (INIS)

    Schmillevitch, J.; Serson, D.; Camera, A.J.; Oliveira Nunes, J.E. de; Bazzo, J.M.B.

    1980-01-01

    Newer modalities for the evaluation of gallbladder include cholescintigraphy and ultrasonography. The IDA-Tc 99m presents functional informations with regard to cystic duct patency. The ultrasonography demonstrates the topographic anatomy of gallbladder, and morfologic alterations. Both analysis are preconized in acute cholecystitis. (Author) [pt

  13. Ultrasonography for clinical decision-making and intervention in airway management: From the mouth to the lungs and pleurae

    DEFF Research Database (Denmark)

    Kristensen, M. S.; Teoh, W. H.; Graumann, O.

    2014-01-01

    OBJECTIVES: To create a state-of-the-art overview of the new and expanding role of ultrasonography in clinical decision-making, intervention and management of the upper and lower airways, that is clinically relevant, up-to-date and practically useful for clinicians. METHODS: This is a narrative...... and help guide timing of removal of chest tubes by quantification of residual pneumothorax size. CONCLUSIONS: Ultrasonography used in conjunction with hands-on management of the upper and lower airways has multiple advantages. There is a rapidly growing body of evidence showing its benefits. TEACHING...

  14. Introital ultrasonography in female urinary incontinence

    Energy Technology Data Exchange (ETDEWEB)

    Weon, Young Cheol; Cho, Kyoung Sik; Lee, Jin Seong; Choi, Sang Hee; Kim, Keon Seok; Choo, Myung Soo [Ulsan Univ. Asan Medical Center, Seoul (Korea, Republic of)

    1996-06-01

    To evaluate the usefulness of introital ultrasonography in the assessment of female urinary incontinence. Introital ultrasonography was performed in fifteen with stress urinary incontinence(mean age 50) and six patients without symptoms of incontinence(mean age 37). Using a sagittal section of the anterior pelvis in the plane of the symphysis pubis the posterior urethrovesical angle, the pubourethral distance and the pubo-yregrak abgle were measured at rest and during stress(Valsalva's maneuver state). The student T-test and the ANOVA test were used in statistical analysis. The posterior urethrovesical angles of the controls were 125.3 deg ({+-}10.9) at rest and 125.7 deg ({+-}7.6) during stress. In the patients, the corresponding angles were 135.3 deg ({+-}11.3) and 139.6 deg({+-}10.8). The posterior urethrovesical angles increased 0.3 deg ({+-}4.7) in the controls and 5.6 deg ({+-}4.0) in the patients(p=0.018). In the controls, the pubo-urethral distances were 21.8 mm({+-}5.8) at rest and 18.2 mm({+-}7.1) during stress, while in the patients these distances were 18.4 mm({+-}3.9) and 12.6 mm({+-}4.4). The pubo-urethral distance decreased 3.5 mm ({+-}1.5) in the controls and 5.8 mm ({+-}2.3) in the patients(p=0.039). In the patients with mild incontinence(Grade I), the posterior urethrovesical angles increased 3.4 deg ({+-}2.8) : 132.3 deg ({+-}12.5) at rest and 135.6 deg (12.8) during stress. In the patients with moderate incontinence(Grade II), the angles increased 8.1 deg({+-}3.8) : 136.0 deg({+-}6.5) at rest and 144.1 deg({+-}5.9) during stress. The change of the posterior urethrovesical angle was related to the grade of urinary incontinence in the patients(p<0.05). There was no statistical significancy in the pubo-urethral angle (p=0.315). Introital ultrasonography may be useful for assessment of stress urinary incontinence.

  15. Spatial weighting of Doppler reactivity feedback

    International Nuclear Information System (INIS)

    Carew, J.F.; Diamond, D.J.; Todosow, M.

    1977-12-01

    The spatial weighting of the local Doppler feedback implicit in the determination of the core Doppler feedback reactivity has been investigated. Using a detailed planar PDQ7-II PWR model with local fuel-temperature feedback, the core Doppler spatial weight factor, S, has been determined for various control patterns and power levels. Assuming power-squared weighting of the local Doppler feedback, a simple analytic expression for S has been derived and, based on comparison with the PDQ7-II results, provides a convenient and accurate representation of the Doppler spatial weight factor. The sensitivity of these results to variations in the fuel rod heat transfer coefficients, fuel loading and the magnitude of the Doppler coefficient has also been evaluated. The dependence of the local Doppler coefficient on moderator temperature, boron concentration and control rod density has been determined and found to be weak. Selected comparisons with vendor analyses have been made and indicate general agreement

  16. Ultrasonography of Skin Changes in Legs with Chronic Venous Disease.

    Science.gov (United States)

    Caggiati, A

    2016-10-01

    In daily practice, ultrasonography (US) is used only to designate the location and pattern of venous lesions. Skin US is not performed between routine venous investigations. Skin morphology is evaluated by the same probes used for routine Duplex evaluation of superficial veins. US findings from evident skin lesions are comparatively evaluated with those from the surrounding apparently normal skin and from the contralateral leg. Inflammation and dermal edema can be found in the apparently normal skin of C2 legs. Swollen legs show thickening of the subcutaneous layer as a result of diffuse soaking or anechoic cavities, with or without dermal edema. Chronic hypodermitis is characterized by inflammatory edema in initial phases, and by liposclerosis in advanced cases. Recrudescence of inflammation provokes focal rarefactions of the subcutaneous layer, possibly related to ulcer opening. In legs with venous disorders, sonography refines clinical evaluation of the skin and may reveal changes not highlighted by inspection. Some of these changes could require further investigation because they have not yet been explained or described. Skin sonography should improve knowledge of the natural history of skin changes, as well as contribute to a better grading of venous diseases severity In particular, US evidence of cutaneous and subcutaneous changes in C2 legs should be considered to stratify the treatment in C2 legs, by identifying those in which varicose veins are not simply a cosmetic problem. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Ultrasonography of the pediatric hip and spine

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yeo Ryang; Koo, Joon Bun [Dept. of Radiology, Dongguk University Ilsan Hospital, Dongguk University College of Medicine, Goyang (Korea, Republic of)

    2017-07-15

    Ultrasonography (US) is a useful screening method for the diagnosis of developmental dysplasia of the hip (DDH) and congenital spinal anomalies in infants. In addition, US is a useful, noninvasive imaging modality for the diagnosis of transient synovitis in children. The early detection of DDH leads to a better prognosis without surgical intervention. Moreover, spinal US allows the detection of congenital malformations and can also demonstrate normal anatomy and normal variants that may resemble disorders. Therefore, radiologists should be familiar with the sonographic anatomy of the normal infant hip, scanning and measurement techniques for DDH, the US features of transient synovitis in children, spinal US techniques, and the US features of normal anatomical structures, normal variants, and congenital spinal anomalies.

  18. Current status of ultrasonography of the finger

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seun Ah; Kim, Baek Hyun [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of); Kim, Seon Jeong [Dept. of Radiology, Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Kim, Ji Na [Dept. of Radiology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon (Korea, Republic of); Park, Sun Young [Dept. of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of); Choi, Kyung Hee [Incheon Baek Hospital, Incheon (Korea, Republic of)

    2016-03-15

    The recent development of advanced high-resolution transducers has enabled the fast, easy, and dynamic ultrasonographic evaluation of small, superficial structures such as the finger. In order to best exploit these advances, it is important to understand the normal anatomy and the basic pathologies of the finger, as exemplified by the following conditions involving the dorsal, volar, and lateral sections of the finger: sagittal band injuries, mallet finger, and Boutonnière deformity (dorsal aspect); flexor tendon tears, trigger finger, and volar plate injuries (volar aspect); gamekeeper’s thumb (Stener lesions) and other collateral ligament tears (lateral aspect); and other lesions. This review provides a basis for understanding the ultrasonography of the finger and will therefore be useful for radiologists.

  19. Shoulder Ultrasonography: Performance and Common Findings

    Directory of Open Access Journals (Sweden)

    Diana Gaitini

    2012-01-01

    Full Text Available Ultrasound (US of the shoulder is the most commonly requested examination in musculoskeletal US diagnosis. Sports injuries and degenerative and inflammatory processes are the main sources of shoulder pain and functional limitations. Because of its availability, low cost, dynamic examination process, absence of radiation exposure, and ease of patient compliance, US is the preferred mode for shoulder imaging over other, more sophisticated, and expensive methods. Operator dependence is the main disadvantage of US examinations. Use of high range equipment with high resolution transducers, adhering to a strict examination protocol, good knowledge of normal anatomy and pathological processes and an awareness of common pitfalls are essential for the optimal performance and interpretation of shoulder US. This article addresses examination techniques, the normal sonographic appearance of tendons, bursae and joints, and the main pathological conditions found in shoulder ultrasonography.

  20. Current status of automated breast ultrasonography

    Directory of Open Access Journals (Sweden)

    Hee Jung Shin

    2015-07-01

    Full Text Available Breast ultrasonography (US is currently considered the first-line examination in the detection Epub ahead of print and characterization of breast lesions. However, conventional handheld US (HHUS has several limitations such as operator dependence and the requirement of a considerable amount of radiologist time for whole-breast US. Automated breast US (ABUS, recently approved by the United States Food and Drug Administration for screening purposes, has several advantages over HHUS, such as higher reproducibility, less operator dependence, and less required physician time for image acquisition. In addition, ABUS provides both a coronal view and a relatively large field of view. Recent studies have reported that ABUS is promising in US screening for women with dense breasts and can potentially replace handheld second-look US in a preoperative setting.

  1. Current status of ultrasonography of the finger

    Directory of Open Access Journals (Sweden)

    Seun Ah Lee

    2016-04-01

    Full Text Available The recent development of advanced high-resolution transducers has enabled the fast, easy, and dynamic ultrasonographic evaluation of small, superficial structures such as the finger. In order to best exploit these advances, it is important to understand the normal anatomy and the basic pathologies of the finger, as exemplified by the following conditions involving the dorsal, volar, and lateral sections of the finger: sagittal band injuries, mallet finger, and Boutonnière deformity (dorsal aspect; flexor tendon tears, trigger finger, and volar plate injuries (volar aspect; gamekeeper’s thumb (Stener lesions and other collateral ligament tears (lateral aspect; and other lesions. This review provides a basis for understanding the ultrasonography of the finger and will therefore be useful for radiologists.

  2. Ultrasonography of the pediatric hip and spine

    International Nuclear Information System (INIS)

    Kang, Yeo Ryang; Koo, Joon Bun

    2017-01-01

    Ultrasonography (US) is a useful screening method for the diagnosis of developmental dysplasia of the hip (DDH) and congenital spinal anomalies in infants. In addition, US is a useful, noninvasive imaging modality for the diagnosis of transient synovitis in children. The early detection of DDH leads to a better prognosis without surgical intervention. Moreover, spinal US allows the detection of congenital malformations and can also demonstrate normal anatomy and normal variants that may resemble disorders. Therefore, radiologists should be familiar with the sonographic anatomy of the normal infant hip, scanning and measurement techniques for DDH, the US features of transient synovitis in children, spinal US techniques, and the US features of normal anatomical structures, normal variants, and congenital spinal anomalies

  3. Prenatal diagnosis of hypophosphatasia congenita using ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Guguloth, Ashwitha [Dept. of Radiology, Bangalore Medical College and Research Institute, Bangalore (India); Aswani, Yashant; Anandpara, Karan Manoj [Dept. of Radiology, Seth G S Medical College and KEM Hospital, Mumbai (India)

    2016-01-15

    Congenital hypophosphatasia is a rare fatal skeletal dysplasia. Antenatal determinants of Epub ahead of print lethality include small thoracic circumference with pulmonary hypoplasia and severe micromelia. These features were present in the fetus of a 25-year-old female who came for an anomaly scan in her second trimester of pregnancy. Additional findings of generalized demineralization and osteochondral spurs led to the diagnosis of hypophosphatasia congenita. The pregnancy was terminated, and the findings were confirmed on autopsy. Common differential diagnoses with clues to diagnose the above mentioned condition have been discussed here. Early and accurate detection of this medical condition is important as no treatment has been established for this condition. Therefore, antenatal ultrasonography helps in diagnosing and decision making with respect to the current pregnancy and lays the foundation for the genetic counseling of the couple.

  4. Compression ultrasonography of the lower extremity with portable vascular ultrasonography can accurately detect deep venous thrombosis in the emergency department.

    Science.gov (United States)

    Crisp, Jonathan G; Lovato, Luis M; Jang, Timothy B

    2010-12-01

    Compression ultrasonography of the lower extremity is an established method of detecting proximal lower extremity deep venous thrombosis when performed by a certified operator in a vascular laboratory. Our objective is to determine the sensitivity and specificity of bedside 2-point compression ultrasonography performed in the emergency department (ED) with portable vascular ultrasonography for the detection of proximal lower extremity deep venous thrombosis. We did this by directly comparing emergency physician-performed ultrasonography to lower extremity duplex ultrasonography performed by the Department of Radiology. This was a prospective, cross-sectional study and diagnostic test assessment of a convenience sample of ED patients with a suspected lower extremity deep venous thrombosis, conducted at a single-center, urban, academic ED. All physicians had a 10-minute training session before enrolling patients. ED compression ultrasonography occurred before Department of Radiology ultrasonography and involved identification of 2 specific points: the common femoral and popliteal vessels, with subsequent compression of the common femoral and popliteal veins. The study result was considered positive for proximal lower extremity deep venous thrombosis if either vein was incompressible or a thrombus was visualized. Sensitivity and specificity were calculated with the final radiologist interpretation of the Department of Radiology ultrasonography as the criterion standard. A total of 47 physicians performed 199 2-point compression ultrasonographic examinations in the ED. Median number of examinations per physician was 2 (range 1 to 29 examinations; interquartile range 1 to 5 examinations). There were 45 proximal lower extremity deep venous thromboses observed on Department of Radiology evaluation, all correctly identified by ED 2-point compression ultrasonography. The 153 patients without proximal lower extremity deep venous thrombosis all had a negative ED compression

  5. The role of transvaginal power Doppler ultrasound in the differential diagnosis of benign intrauterine focal lesions.

    Science.gov (United States)

    Cogendez, Ebru; Eken, Meryem Kurek; Bakal, Nuray; Gun, Ismet; Kaygusuz, Ecmel Isik; Karateke, Ates

    2015-10-01

    The purpose of this prospective study was to assess the role of power Doppler imaging in the differential diagnosis of benign intrauterine focal lesions such as endometrial polyps and submucous myomas using the characteristics of power Doppler flow mapping. A total of 480 premenopausal patients with abnormal uterine bleeding were evaluated by transvaginal ultrasonography (TVS) searching for intrauterine pathology. Sixty-four patients with a suspicious focal endometrial lesion received saline infusion sonography (SIS) after TVS. Fifty-eight patients with focal endometrial lesions underwent power Doppler ultrasound (PDUS). Three different vascular flow patterns were defined: Single vessel pattern, multiple vessel pattern, and circular flow pattern. Finally, hysteroscopic resection was performed in all cases, and Doppler flow characteristics were then compared with the final histopathological findings. Histopathological results were as follows: endometrial polyp: 40 (69 %), submucous myoma: 18 (31 %). Of the cases with endometrial polyps, 80 % demonstrated a single vessel pattern, 7.5 % a multiple vessel pattern, and 0 % a circular pattern. Vascularization was not observed in 12.5 % of patients with polyps. Of the cases with submucousal myomas, 72.2 % demonstrated a circular flow pattern, 27.8 % a multiple vessel pattern, and none of them showed a single vessel pattern. The sensitivity, specificity, and positive and negative predictive values of the single vessel pattern in diagnosing endometrial polyps were 80, 100, 100, and 69.2 %, respectively; and for the circular pattern in diagnosing submucous myoma, these were 72.2, 100, 100, and 88.9 %, respectively. Power Doppler blood flow mapping is a useful, practical, and noninvasive diagnostic method for the differential diagnosis of benign intrauterine focal lesions. Especially in cases of recurrent abnormal uterine bleeding, recurrent abortion, and infertility, PDUS can be preferred as a first-line diagnostic method.

  6. Doppler tomography in fusion plasmas and astrophysics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Heidbrink, W. W.

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion Dα (FIDA) spectroscopy measurements in magnetically confined plasma......, the Dα-photons are likewise Doppler-shifted ultimately due to gyration of the fast ions. In either case, spectra of Doppler-shifted line emission are sensitive to the velocity distribution of the emitters. Astrophysical Doppler tomography has lead to images of accretion discs of binaries revealing bright...... and limits, analogies and differences in astrophysical and fusion plasma Doppler tomography and what can be learned by comparison of these applications....

  7. Measurement of ventricular function using Doppler ultrasound

    International Nuclear Information System (INIS)

    Teague, S.M.

    1986-01-01

    Doppler has wide application in the evaluation of valvular heart disease. The need to know ventricular function is a much more common reason for an echocardiographic evaluation. Interestingly, Doppler examinations can assess ventricular function from many perspectives. Description of ventricular function entails measurement of the timing, rate and volume of ventricular filling and ejection. Doppler ultrasound examination reveals all of these aspects of ventricular function noninvasively, simply, and without great expense or radiation exposure, as described in this chapter

  8. Endoscopic Ultrasonography in the Diagnosis of Gastric Subepithelial Lesions

    Directory of Open Access Journals (Sweden)

    Eun Jeong Gong

    2016-09-01

    Full Text Available Subepithelial lesions occasionally found in the stomach of patients undergoing endoscopy may be either benign lesions or tumors with malignant potential. They may also appear due to extrinsic compression. Discrimination of gastric subepithelial lesions begins with meticulous endoscopic examination for size, shape, color, mobility, consistency, and appearance of the overlying mucosa. Accurate diagnosis can be achieved with endoscopic ultrasonography, which provides useful information on the exact size, layer-of-origin, and characteristic morphologic features to support a definitive diagnosis. Endoscopic ultrasonography also aids in the prediction of malignant potential, especially in gastrointestinal stromal tumors. Features of subepithelial lesions identified on endoscopic ultrasonography can be used to determine whether further diagnostic procedures such as endoscopic resection, fine needle aspiration, or core biopsy are required. Endoscopic ultrasonography is a valuable tool for diagnosis and clinical decision making during follow-up of gastric subepithelial lesions.

  9. Normal values for quantitative muscle ultrasonography in adults.

    NARCIS (Netherlands)

    Arts, I.M.P.; Pillen, S.; Schelhaas, H.J.; Overeem, S.; Zwarts, M.J.

    2010-01-01

    Ultrasonography can detect structural muscle changes caused by neuromuscular disease. Quantitative analysis is the preferred method to determine if ultrasound findings are within normal limits, but normative data are incomplete. The purpose of this study was to provide normative muscle

  10. Ultrasonography as a diagnostic method in addition to mammography

    Energy Technology Data Exchange (ETDEWEB)

    Otto, H.; Roer, E.

    1988-05-01

    By using ultrasonography in addition to mammography, experienced diagnosticians essentially enhance the safety of their diagnosis of mammary gland diseases. The same applies to gynecomastia, the condition after plastic surgery, and mastitis.

  11. Direct Doppler auscultation of the carotid arteries

    International Nuclear Information System (INIS)

    Nix, L.

    1984-01-01

    The results of the carotid Doppler examinations and contrast arteriograms are presented. The overall sensitivity of the carotid Doppler examinations in detecting severe stenosis or occlusion of the carotid artery was 92%. The Doppler studies correctly differentiated these two conditions in 84% of the diseased vessels. In carotid arteries with stenosis greater than or equal to 50%, the sensitivity of the Doppler examinations was 90%, and these studies suggested stenosis in all but two of the 36 abnormal examinations. In two patent carotids with greater than 90% stenosis, a signal could not be elicited, presumably because of the low blood flow through the severely stenotic segment

  12. Reproducibility of duplex ultrasonography and air plethysmography used for the evaluation of chronic venous insufficiency.

    Science.gov (United States)

    Asbeutah, Akram Mahmoud; Riha, Andrea Zdena; Cameron, James Donald; McGrath, Barry Patrick

    2005-04-01

    The purpose of this study was to determine the reproducibility of measurements on duplex ultrasonography (DU) and air plethysmography (APG) in subjects with post-thrombotic syndrome. Duplex ultrasonography and APG were used to measure indices of lower limb venous reflux in 15 limbs with a history of deep vein thrombosis and evidence of venous insufficiency as diagnosed by ultrasonography. Three limbs were in class 0; 4 were in classes 1 to 3; and 8 were in classes 4 to 6, according to clinical, etiologic, anatomic, and pathophysiologic clinical classification. Duplex ultrasonography was performed 3 times on the same day, and venous diameter, area, peak reflux velocity, reflux flow volume, and reflux duration measurements were obtained. Air plethysmography was performed on 2 days, 7 to 10 days apart, with 1 measurement on the first day and 2 measurements on the second day. Values obtained from APG included outflow fraction, venous filling index, ejection fraction, and residual volume fraction. The measurements were performed by a vascular technologist blinded to the previous test results. One-way analysis of variance, the Student paired t test, and Bland-Altman plots were used to examine the statistical differences of the DU and APG parameters for all measurements. The mean coefficient of variation for within-subject measurements of all DU and APG parameters measured was less than 10%. Bland-Altman plots showed that there were no apparent trends with increasing values over a wide range for any of the DU parameters, nor were there any for the APG parameters. Under ideal conditions, when measured by a highly trained technologist, both DU and APG showed satisfactory reproducibility.

  13. The predictive diagnostic value of serial daily bedside ultrasonography for severe dengue in Indonesian adults.

    Directory of Open Access Journals (Sweden)

    Meta Michels

    Full Text Available BACKGROUND: Identification of dengue patients at risk for progressing to severe disease is difficult. Significant plasma leakage is a hallmark of severe dengue infection which can suddenly lead to hypovolemic shock around the time of defervescence. We hypothesized that the detection of subclinical plasma leakage may identify those at risk for severe dengue. The aim of the study was to determine the predictive diagnostic value of serial ultrasonography for severe dengue. METHODOLOGY/PRINCIPAL FINDINGS: Daily bedside ultrasounds were performed with a handheld ultrasound device in a prospective cohort of adult Indonesians with dengue. Timing, localization and relation to dengue severity of the ultrasonography findings were determined, as well as the relation with serial hematocrit and albumin values. The severity of dengue was retrospectively determined by WHO 2009 criteria. A total of 66 patients with proven dengue infection were included in the study of whom 11 developed severe dengue. Presence of subclinical plasma leakage at enrollment had a positive predictive value of 35% and a negative predictive value of 90% for severe dengue. At enrollment, 55% of severe dengue cases already had subclinical plasma leakage, which increased to 91% during the subsequent days. Gallbladder wall edema was more pronounced in severe than in non-severe dengue patients and often preceded ascites/pleural effusion. Serial hematocrit and albumin measurements failed to identify plasma leakage and patients at risk for severe dengue. CONCLUSIONS/SIGNIFICANCE: Serial ultrasonography, in contrast to existing markers such as hematocrit, may better identify patients at risk for development of severe dengue. Patients with evidence of subclinical plasma leakage and/or an edematous gallbladder wall by ultrasonography merit intensive monitoring for development of complications.

  14. Ultrasonography as a better diagnostic efficiency in rib fracture

    OpenAIRE

    UZUN, Metin; BEKSAÇ, Burak; KARATAŞ, Adnan; KÜÇÜKDURMAZ, Fatih; KIRCALI, Bahar ANAYURDU; TETİK, Cihangir

    2013-01-01

    In this study, our aim was to demonstrate the need of use of ultrasonography in rib fractures in order not to face medicolegal problems. One hundred patients admitted to our emergency service with mild to moderate blunt thorax trauma were included in our study prospectively. The inclusion criteria were pain upon palpation of ribs, deep inspiration, coughing but no any other pathologies like a pneumothorax, hemothorax. All patients are evaluated with ultrasonography (USG) and direct X-rays. X-...

  15. Ultrasonography of the lower extremity veins: Anatomy and basic approach

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Kyu; Ahn, Kyung Sik; Kang, Chang Ho; Cho, Sung Bum [Dept. of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Ultrasonography is an imaging modality widely used to evaluate venous diseases of the lower extremities. It is important to understand the normal venous anatomy of the lower extremities, which has deep, superficial, and perforating venous components, in order to determine the pathophysiology of venous disease. This review provides a basic description of the anatomy of the lower extremity veins and useful techniques for approaching each vein via ultrasonography.

  16. Intraoperative ultrasonography in detection of hepatic metastases from colorectal cancer

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael; Kronborg, Ole; Fenger, Claus

    1995-01-01

    PURPOSE: This study was designed to compare diagnostic accuracies of measuring liver enzymes, preoperative ultrasonography, surgical examination, and intraoperative ultrasonography for detection of liver metastases from colorectal cancer. METHODS: Blind, prospective comparisons of diagnostic...... examinations mentioned above were performed in 295 consecutive patients with colorectal cancer. An experienced ultrasonologist performed the preoperative examinations, and results were unknown to the other experienced ultrasonologist who performed the intraoperative examinations. The latter, also was unaware...

  17. Ultrasonography of the lower extremity veins: Anatomy and basic approach

    International Nuclear Information System (INIS)

    Lee, Dong Kyu; Ahn, Kyung Sik; Kang, Chang Ho; Cho, Sung Bum

    2017-01-01

    Ultrasonography is an imaging modality widely used to evaluate venous diseases of the lower extremities. It is important to understand the normal venous anatomy of the lower extremities, which has deep, superficial, and perforating venous components, in order to determine the pathophysiology of venous disease. This review provides a basic description of the anatomy of the lower extremity veins and useful techniques for approaching each vein via ultrasonography

  18. Acute diverticulitis of the terminal ileum: ultrasonography and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jewon; Hong, Seong Sook; Hwang, Ji Young; Kim, Hyun Joo; Chang, Yun Woo [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    2015-01-15

    We describe a rare case of terminal ileal diverticulitis in a 68-year-old female with a day of history Epub ahead of print of right lower quadrant pain and tenderness, mimicking acute appendicitis. Ultrasonography revealed small sac-like out-pouching lesions with increased echogenicity of surrounding fat in thickened terminal ileum, suggesting inflamed diverticula. We diagnosed terminal ileal diverticulitis primarily by ultrasonography. The diagnosis was confirmed by subsequent computed tomography.

  19. Ultrasonography for Noninvasive Assessment of Portal Hypertension.

    Science.gov (United States)

    Maruyama, Hitoshi; Yokosuka, Osamu

    2017-07-15

    Portal hypertension is a major pathophysiology in patients with cirrhosis. Portal pressure is the gold standard to evaluate the severity of portal hypertension, and radiological intervention is the only procedure for pressure measurement. Ultrasound (US) is a simple and noninvasive imaging modality available worldwide. B-mode imaging allows broad applications for patients to detect and characterize chronic liver diseases and focal hepatic lesions. The Doppler technique offers real-time observation of blood flow with qualitative and quantitative assessments, and the application of microbubble-based contrast agents has improved the detectability of peripheral blood flow. In addition, elastography for the liver and spleen covers a wider field beyond the original purpose of fibrosis assessment. These developments enhance the practical use of US in the evaluation of portal hemodynamic abnormalities. This article reviews the recent progress of US in the assessment of portal hypertension.

  20. Transcranial doppler: Technique and common findings (Part 1

    Directory of Open Access Journals (Sweden)

    Lokesh Bathala

    2013-01-01

    Full Text Available Transcranial Doppler (TCD can be aptly called as the doctor′s stethoscope of the brain. Since its introduction in 1982, by Rune Aaslid, TCD has evolved as a diagnostic, monitoring, and therapeutic tool. During evaluation of patients with acute ischemic stroke, TCD combined with cervical duplex ultrasonography provides physiological information on the cerebral hemodynamics, which is often complementary to structural imaging. Currently, TCD is the only diagnostic tool that can provide real time information about cerebral hemodynamics and can detect embolization to the cerebral vessels. TCD is a noninvasive, cost-effective, and bedside tool for obtaining information regarding the collateral flow across various branches of the circle of Willis in patients with cerebrovascular disorders. Advanced applications of TCD help in the detection of right-to-left shunts, vasomotor reactivity, diagnosis, and monitoring of vasospasm in subarachnoid hemorrhage and as a supplementary test for confirmation of brain death. This article describes the basic ultrasound physics pertaining to TCD insonation methods, for detecting the flow in intracranial vessels in addition to the normal and abnormal spectral flow patterns.

  1. Ultrasonography of the shoulder: pitfalls and variants

    International Nuclear Information System (INIS)

    Friedman, L.; Finlay, K.; Popowich, T.; Jurriaans, E.

    2002-01-01

    Ultrasonography (US) of the shoulder, particularly the evaluation of the rotator cuff, is the most common examination of the musculoskeletal system performed in most practices. Despite this, it remains one of the most difficult examinations to learn. There are many pitfalls and errors that can occur initially, but once mastered, US of the rotator cuff is one of the best methods available for diagnosing rotator cuff disease. The literature reports a 91%-95% sensitivity and close to 90% specificity and accuracy in the assessment of both partial and full thickness tears. This compares favourably with magnetic resonance imaging (MRI), where a more recent study reported an 84% sensitivity, 97% specificity and an accuracy of 93% for combined partial and full thickness tears of the rotator cuff. Advantages of US include low cost, easy access, high degree of accuracy in expert hands, ease of comparison with the opposite side, dynamic real-time examination, ability to focus on the exact site of the patient's pain and graded compression availability. It is for these reasons that we hope to outline the various pitfalls and common errors that can occur during the examination in a systematic fashion. It must also be pointed out that computed tomographic arthrography and magnetic resonance arthrography remain the investigations of choice for assessing labral disorders. (author)

  2. New endoscopic ultrasonography techniques for pancreticobiliary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kamata, Ken; Kitano, Masayuki; Omoto, Shunsuke; Kadosaka, Kumpei; Miyata, Takeshi; Minaga, Kosuke; Yamao, Kentaro; Imai, Hajime; Kudo, Masatoshii [Dept. of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka (Japan)

    2016-07-15

    Endoscopic ultrasonography (EUS) is widely used to evaluate pancreaticobiliary diseases, especially pancreatic masses. EUS has a good ability to detect pancreatic masses, but it is not sufficient for the differential diagnosis of various types of lesions. In order to address the limitations of EUS, new techniques have been developed to improve the characterization of the lesions detected by EUS. EUS-guided fine needle aspiration (EUS-FNA) has been used for diagnosing pancreatic tumors. In order to improve the histological diagnostic yield, a EUS-FNA needle with a core trap has recently been developed. Contrast-enhanced harmonic EUS is a new imaging modality that uses an ultrasonographic contrast agent to visualize blood flow in fine vessels. This technique is useful in the diagnosis of pancreatic solid lesions and in confirming the presence of vascularity in mural nodules for cystic lesions. EUS elastography analyzes several different variables to measure tissue elasticity, color patterns, and strain ratio, using analytical techniques such as hue-histogram analysis, and artificial neural networks, which are useful for the diagnosis of chronic pancreatitis and pancreatic cancer.

  3. Rupture of Achilles Tendon : Usefulness of Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Ki, Won Woo; Yoon, Kwon Ha; Kim, Song Mun; Shin, Myeong Jin; Kwon, Soon Tae

    1996-01-01

    To differentiate a complete rupture of Achilles tendon from an incomplete one which is important because its treatment is quite different. And it is necessary to know the exact site of the rupture preoperatively. Fifteen cases of fourteen patients which were diagnosed as Achilles tendon rupture by ultrasonography and surgery were reviewed. We compared sonographic rupture site with surgical findings. Ultrasonographic criteria for differentiation of complete and incomplete rupture was defined as follows : the discreteness, which means the proximal intervening hypoechogenicity to the interface echogenicity of distal margin of ruptured tendon : the slant sign, which represents the interface of ruptured distal margin which was seen over the 3/4 of the thickness of the tendon without intervening low echogeneicity : the invagination sign, which means the echogenic invagination from Kager triangle into posterior aspect of Achilles tendon over the half thickness of the tendon. The sites of complete tendon rupture were exactly corresponded to surgical finding in four cases of ten complete ruptures. And the discrepancy between sonographic and surgical findings in the site of complete rupture was 1.2 ± 0.4 cm in six cases. Three of ten complete ruptures showed the discreteness sign, all of ten showed the slant sign and two of ten showed the invagination sign. It is helpful to differentiate a complete from incomplete rupture of the Achilles tendon and to localize the site of the complete rupture with the ultrasonographic evaluation

  4. Ultrasonography of hydronephrosis and renal masses

    International Nuclear Information System (INIS)

    Lee, Kyung Weon; Kim, Chong Gun; Kim, Yeon Jin; Rhee, Byung Chull

    1984-01-01

    We have analyzed ultrasonographic findings of 55 cases of hydronephrosis and 34 cases of renal masses. The results are as follows: 1. 55 cases of hydronephrosis revealed renal enlargement in 55 cases, separation of central echo complex in 27 cases, multiple anechoic areas radiating from the center in 25 cases and dilated renal pelvis in 24 cases. 2. Among the masses in 34 cases, simple renal cyst were 15 cases, polycystic kidney in 8 cases, hypernephroma in 8 cases, Wilm's tumor in 2 cases and agiomyolipoma in 1 case. 3. Simple renal cyst revealed single in 14 cases (93%) and well defined anechoic mass with posterior enhancement in all cases. 4. Polycystic kidney revealed bilateral irregular shaped renal enlargement and multiple anechoic cysts throughout the kidney. 2 cases (25%) involved liver. 5. 6 cases (75%) of hypernephroma revealed ill defined moderately echogenic mass without posterior enhancement. 6. All cases of Wilm's tumor revealed well defined large mixed echogenic mass in right kidney. 7. Angiomyolipoma revealed bilateral dense echogenic mass with large hemorrhage cyst in right kidney. 8. The ultrasonography is useful noninvasive diagnostic modality of evaluation of renal masses and hydronephrosis.

  5. Color/power Doppler transrectal US in prostate cancer: Correlation with Gleason score

    International Nuclear Information System (INIS)

    Kim, Hyo Cheol; Kim, Seung Hyup; Moon, Min Hoan; Park, Byung Kwan; Kim, Keon Ha; Choi, Hyuck Jae; Yoon, Chang Jin

    2002-01-01

    To evaluate the relationship between hypervascularity on color/power Doppler transrectal ultrasonography and the Gleason score of corresponding biopsied specimen in patients with prostatic cancer. From July 1998 to March 2002, one hundred fifty seven patients with pathologically proven prostate cancer at this institution were included, and all of them underwent transrectal ultrasonographic examination. Initially, ultrasonographic findings and pathologic data of 129 patients were retrospectively reviewed and excluded 28 patients whose sonographic images were either unavailable or inconclusive. The presence of hypoechoic lesion on transrectal sonography and hypervascularity on color/power Doppler sonography in the peripheral zone of the prostate was first evaluated, and these sonographic findings and Gleason score of the corresponding biopsied specimen were then compared. Statistical analysis was done by Student t-test using SPSS package. Among one hundred twenty nine patients, ninety four patients had a hypoechoic lesion on gray scale sonography while sixty one showed a hypervascular lesion on color/power Doppler sonography. Fifty seven of 61 patients (93.4%) had hypoechoic lesion on gray scale sonography. The mean Gleason score of patients with hypervascular lesion was 7.9 ± 0.98 whereas that of the patients without hypervascular lesion, 6.9 ± 1.22, showing a statistically significant difference (p<0.01). Prostate cancer with hypervascularity on transrectal sonography appears to have a higher Gleason score on pathologic examination than that without hypervascularity.

  6. Glare Spot Phase Doppler Anemometry

    Science.gov (United States)

    Hespel, Camille; Ren, Kuanfang; Gréhan, Gérard; Onofri, Fabrice

    2007-06-01

    The Phase Doppler anemometry has been developed to measure simultaneously the velocity and the size of droplets. The measurement of the refractive index would be also interesting since it depends on the temperature and the composition of the particle and its measurement permits both to increase the quality of the diameter measurement and to obtain information on the temperature and/or the composition of the droplets. In this paper, we introduce a Glare Spot Phase Doppler Anemometry which uses two large beams. In this case, the images of the particle formed by the reflected and refracted light, known as glare spots, are separated in space. When a particle passes in the probe volume, the two parts in a signal obtained by a detector in forward direction are then separated in time. If two detectors are used the phase differences between two signals, the distance and the intensity ratio of reflected and refracted parts can be obtained and they provide rich information about the particle diameter and its refractive index, as well as its velocity. This paper is devoted to the numerical study of such a configuration with two theoretical models: geometrical optics and rigorous electromagnetism solution.

  7. Acute Effects of Lateral Thigh Foam Rolling on Arterial Tissue Perfusion Determined by Spectral Doppler and Power Doppler Ultrasound.

    Science.gov (United States)

    Hotfiel, Thilo; Swoboda, Bernd; Krinner, Sebastian; Grim, Casper; Engelhardt, Martin; Uder, Michael; Heiss, Rafael U

    2017-04-01

    Hotfiel, T, Swoboda, B, Krinner, S, Grim, C, Engelhardt, M, Uder, M, and Heiss, R. Acute effects of lateral thigh foam rolling on arterial tissue perfusion determined by spectral Doppler and power Doppler ultrasound. J Strength Cond Res 31(4): 893-900, 2017-Foam rolling has been developed as a popular intervention in training and rehabilitation. However, evidence on its effects on the cellular and physiological level is lacking. The aim of this study was to assess the effect of foam rolling on arterial blood flow of the lateral thigh. Twenty-one healthy participants (age, 25 ± 2 years; height, 177 ± 9 cm; body weight, 74 ± 9 kg) were recruited from the medical and sports faculty. Arterial tissue perfusion was determined by spectral Doppler and power Doppler ultrasound, represented as peak flow (Vmax), time average velocity maximum (TAMx), time average velocity mean (TAMn), and resistive index (RI), and with semiquantitative grading that was assessed by 4 blindfolded investigators. Measurement values were assessed under resting conditions and twice after foam rolling exercises of the lateral thigh (0 and 30 minutes after intervention). The trochanteric region, mid portion, and distal tibial insertion of the lateral thigh were representative for data analysis. Arterial blood flow of the lateral thigh increased significantly after foam rolling exercises compared with baseline (p ≤ 0.05). We detected a relative increase in Vmax of 73.6% (0 minutes) and 52.7% (30 minutes) (p power Doppler scores at all portions revealed increased average grading of 1.96 after intervention and 2.04 after 30 minutes compared with 0.75 at baseline. Our results may contribute to the understanding of local physiological reactions to self-myofascial release.

  8. The Contribution of Three-Dimensional Power Doppler Imaging in the Preoperative Assessment of Breast Tumors: A Preliminary Report

    Directory of Open Access Journals (Sweden)

    K. Kalmantis

    2009-01-01

    Methods. One hundred and twenty five women with clinically or mammographically suspicious findings were referred for 3D Power Doppler ultrasound prior to surgery. Histological diagnosis was conducted after surgery and compared with ultrasound findings. Sonographic criteria used for breast cancer diagnosis were based on a system that included morphological characteristics and criteria of the vascular pattern of a breast mass by Power Doppler imaging. Results. Seventy-two lesions were histopathologically diagnosed as benign and 53 tumors as malignant. Three-dimensional ultrasound identified 49 out of 53 histologically confirmed breast cancers resulting in a sensitivity of 92.4% and a specificity of 86.1% in diagnosing breast malignancy (PPV: 0.83, NPV:0.94. Conclusions. 3D ultrasonography is a valuable tool in identifying preoperatively the possibility of a tumor to be malignant.

  9. Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs

    Directory of Open Access Journals (Sweden)

    Elzivânia G. Silva

    Full Text Available ABSTRACT: B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1, anterior chamber depth (M2, lens thickness (M3, lens length (M4, vitreous chamber depth (M5, optical disc length (M6 and optic nerve diameter (M7. Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS, final diastolic velocity (VDF, resistivity index (IR and pulse index (IP. No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05. The vitreous chamber depth (M5 was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left eye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05. The mean resistivity index (RI showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities

  10. Radar Doppler Processing with Nonuniform Sampling.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Conventional signal processing to estimate radar Doppler frequency often assumes uniform pulse/sample spacing. This is for the convenience of t he processing. More recent performance enhancements in processor capability allow optimally processing nonuniform pulse/sample spacing, thereby overcoming some of the baggage that attends uniform sampling, such as Doppler ambiguity and SNR losses due to sidelobe control measures.

  11. Comparison of brucella and non-specific epididymorchitis: gray scale and color Doppler ultrasonographic features

    International Nuclear Information System (INIS)

    Ozturk, Adil; Ozturk, Ebru; Zeyrek, Fadile; Onur, Kahraman; Sirmatel, Ocal; Kat, Nurcan

    2005-01-01

    Objective: The aim of this study is to find out if it is possible to differentiate between brucellar and non-specific epididymorchitis by comparing ultrasonography (US) and color Doppler ultrasonography (CDUS) findings. Material and methods: Fifty-six patients diagnosed to have epididymorchitis both clinically and ultrasonographically were included to study. All of the patients were investigated serologically for brucella. Twenty-eight of those patients were admitted brucella epididymorchitis because of high agglutinations titers for brucella. The other 28 patients were admitted non-specific epididymorchitis because of normal agglutinations titers for brucella. Testicular size, echogenicity, hydrocele, internal echoes and/or septations within hydrocele, and scrotal skin thickness of normal and involved testis were compared by ultrasonography. Besides, pick systolic velocity, end diastolic velocity, resistive index and pick systolic velocity ratio values were measured by bilateral testicular color Doppler ultrasonography in both groups. When the p-value is <0.05, the difference between groups is accepted as statistically significant. Results: Thickening of scrotal skin was seen in 17 of 28 patients with brucella epididymorchitis (BEPO) (67%) and in 25 of 28 patients with non-specific epididymorchitis (NEPO) (89.2%) (p < 0.01). There was no difference between groups regarding presence of hydrocele. However hydrocele seen in all patients was anechoic except for two patients (8.6%). Hydrocele seen in 18 of 22 patients with BEPO and hydrocele had internal echogenicity or septation (p < 0.001). Sizes of testes and epididymis were found to be increased in involved testis compared to normal testis. Testes of all patients with NEPO were homogenous with decreased echogenicity except for five patients (17.8%). However, 23 patients with BEPO (82%) found to have heterogenous testis (p < 0.001). Spectral measurements showed increased PSV and EDV values and decreased RI values in

  12. Comparison of brucella and non-specific epididymorchitis: gray scale and color Doppler ultrasonographic features

    Energy Technology Data Exchange (ETDEWEB)

    Ozturk, Adil [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey)]. E-mail: ozturka26@hotmail.com; Ozturk, Ebru [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey); Zeyrek, Fadile [Department of Microbiology, Harran University School of Medicine, Sanliurfa (Turkey); Onur, Kahraman [Department of Urology, SSK Sanliurfa Hastanesi, Sanliurfa (Turkey); Sirmatel, Ocal [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey); Kat, Nurcan [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey)

    2005-11-01

    Objective: The aim of this study is to find out if it is possible to differentiate between brucellar and non-specific epididymorchitis by comparing ultrasonography (US) and color Doppler ultrasonography (CDUS) findings. Material and methods: Fifty-six patients diagnosed to have epididymorchitis both clinically and ultrasonographically were included to study. All of the patients were investigated serologically for brucella. Twenty-eight of those patients were admitted brucella epididymorchitis because of high agglutinations titers for brucella. The other 28 patients were admitted non-specific epididymorchitis because of normal agglutinations titers for brucella. Testicular size, echogenicity, hydrocele, internal echoes and/or septations within hydrocele, and scrotal skin thickness of normal and involved testis were compared by ultrasonography. Besides, pick systolic velocity, end diastolic velocity, resistive index and pick systolic velocity ratio values were measured by bilateral testicular color Doppler ultrasonography in both groups. When the p-value is <0.05, the difference between groups is accepted as statistically significant. Results: Thickening of scrotal skin was seen in 17 of 28 patients with brucella epididymorchitis (BEPO) (67%) and in 25 of 28 patients with non-specific epididymorchitis (NEPO) (89.2%) (p < 0.01). There was no difference between groups regarding presence of hydrocele. However hydrocele seen in all patients was anechoic except for two patients (8.6%). Hydrocele seen in 18 of 22 patients with BEPO and hydrocele had internal echogenicity or septation (p < 0.001). Sizes of testes and epididymis were found to be increased in involved testis compared to normal testis. Testes of all patients with NEPO were homogenous with decreased echogenicity except for five patients (17.8%). However, 23 patients with BEPO (82%) found to have heterogenous testis (p < 0.001). Spectral measurements showed increased PSV and EDV values and decreased RI values in

  13. An analysis of 1018 cases of ultrasonography

    International Nuclear Information System (INIS)

    Kim, Chu Wan; Suh, Jeong Soo; Lee, Kwan Seh; Kim, Ki Hwan; Im, Chung Gie; Chang, Kee Hyun; Yeon, Kyung Mo; Han, Man Chung; Choo, Dong Woon

    1985-01-01

    Ultrasound is an especially helpful diagnostic tool in assessing various diseases in various organs as well as differentiating cystic masses from solid ones, with ease safety, reproducibility, and high accuracy. Authors analyzed total 1018 cases of ultrasonography that were studied in last seven months from March. 15. 1979 to October. 31. 1979, at the Department of Radiology, Seoul National University Hospital. The results were as follows: 1. Among the 1018 cases, 421 cases were male and 597 cases of female. The age distribution was from several months to 83 years, and 88% of all cases were in 20 to 69 years of age. 2. Sites of scanning; Liver, G.B. and biliary systems 376, thyroid 185, kidney 192, pelvis 121, abdomen 70, pancreas 48, eyeball 14, and other 12. 3. Hepatobiliary system 376; Normal 174, hepatomegaly 12, hepatoma 7, metastases 6, abscess 6, cirrhosis 2, hepatic cyst 1, hemangioma 1, agenesis of left lobe 1. 4. G.B. stones 106, cholecystitis 35, biliary tree dilatation 13, enlarged G.B. 7, C.B.D. stone 5, cystic duct stone 4, C.B.D. cancer 6, G.B. cancer 1, choledochal cyst 1, non-visualized G.B. 8. 5. Thyroid, 185; Nodule 147 -- solid 56, cystic 70, complex 21, Diffuse enlargement 29, normal scan 7, unidentified 2. 6. Pancreas, 48; Normal 17, pancreastitis 4, pancreatic cancer 22, pseudocyst 4, unidentified 1. 7. Abdomen 77 (excluding liver, G.B. and pancreas); Normal scan 31, solid tumor 14 - lymphoma group 12, mesenchyma origin 2, multiple lymph node enlargement 13, aortic aneurysm 4, retroperitoneal mass 2, subphrenic abscess 2, abdominal wall abscess 2, unknown solid mass 4, not contributory 4. 8. Kidney, 194, Normal scan 44, size and markings for biopsy 75, hydronephrosis 21, renal cyst 8, polycystic disease 8, solid renal tumor 10, renal stone 7, agenesis or hypoplasia 2, contracted kidney, both 7, enlarge kidney due to lymphoma and compensatory hyperplasia 5, renal tbc 2, perirenal abscess 1, perirenal hematoma 1, movable kidney 1, bladder tumor

  14. Additional prognostic value of physical examination, exercise testing, and arterial ultrasonography for coronary risk assessment in primary prevention.

    Science.gov (United States)

    Cournot, Maxime; Taraszkiewicz, Dorota; Cambou, Jean-Pierre; Galinier, Michel; Boccalon, Henri; Hanaire-Broutin, Hélène; Chamontin, Bernard; Carrié, Didier; Ferrières, Jean

    2009-11-01

    The choice of noninvasive tests used in primary prevention of cardiovascular diseases must be based on medical evidence. The aim of this study was to assess the additional prognostic value, over conventional risk factors, of physical examination, exercise testing, and arterial ultrasonography, in predicting a first coronary event. A prospective cohort study was conducted between 1996 and 2004 (n = 2,709), with follow-up in 2006 (response rate 96.6%). Participants had no history or symptoms of cardiovascular disease and had a standardized physical examination, a cardiac exercise testing, and carotid and femoral ultrasonography at baseline. Incident cases of definite coronary events were recorded during follow-up. Over the Framingham risk score, femoral bruit, positive exercise test, intima-media thickness >0.63 mm, and a femoral plaque provided significant additional information to the prediction model. The addition of the exercise test to the traditional risk factors, then the intima-media thickness and lastly the presence of femoral plaques, produces incremental increases in the area under the receiver operating characteristic curve (0.73-0.78, P = .02) and about a 50% increase in the positive predictive value (15.8%-31.4%), with no effect on the negative predictive value (96.4%-96.9%). Physical examination, exercise testing, and arterial ultrasonography provide incremental information on the risk of coronary event in asymptomatic adults. Exercise testing and femoral ultrasonography also improve the accuracy of the risk stratification.

  15. Estimating the Doppler centroid of SAR data

    DEFF Research Database (Denmark)

    Madsen, Søren Nørvang

    1989-01-01

    attractive properties. An evaluation based on an existing SEASAT processor is reported. The time-domain algorithms are shown to be extremely efficient with respect to requirements on calculations and memory, and hence they are well suited to real-time systems where the Doppler estimation is based on raw SAR......After reviewing frequency-domain techniques for estimating the Doppler centroid of synthetic-aperture radar (SAR) data, the author describes a time-domain method and highlights its advantages. In particular, a nonlinear time-domain algorithm called the sign-Doppler estimator (SDE) is shown to have...... data. For offline processors where the Doppler estimation is performed on processed data, which removes the problem of partial coverage of bright targets, the ΔE estimator and the CDE (correlation Doppler estimator) algorithm give similar performance. However, for nonhomogeneous scenes it is found...

  16. Randomized controlled trial on effectiveness of ultrasonography screening for breast cancer in women aged 40-49 (J-START). Research design

    International Nuclear Information System (INIS)

    Ohuchi, Noriaki; Ishida, Takanori; Kawai, Masaaki; Narikawa, Yoko; Yamamoto, Seiichiro; Sobue, Tomotaka

    2011-01-01

    In cancer screening, it is essential to undertake effective screening with appropriate methodology, which should be supported by evidence of a reduced mortality rate. At present, mammography is the only method for breast cancer screening with such evidence. However, mammography does not achieve sufficient accuracy in breasts with high density at ages below 50. Although ultrasonography achieves better accuracy in Breast Cancer detection even in dense breasts, the effectiveness has not been verified. We have planned a randomized controlled trial to assess the effectiveness of ultrasonography in women aged 40-49, with a design to study 50,000 women with mammography and ultrasonography (intervention group), and 50,000 controls with mammography only (control group). The participants are scheduled to take second round screening with the same modality 2 years on. The primary endpoints are sensitivity and specificity, and the secondary endpoint is the rate of advanced breast cancers. (author)

  17. Endoscopic ultrasonography-guided rendezvous technique.

    Science.gov (United States)

    Tsuchiya, Takayoshi; Itoi, Takao; Sofuni, Atsushi; Tonozuka, Ryosuke; Mukai, Shuntaro

    2016-04-01

    Endoscopic retrograde cholangiopancreatography (ERCP) requires deep biliary cannulation. When deep biliary cannulation is failed, the endoscopic ultrasonography rendezvous technique (EUS-RV) is a useful salvage method. From the previous 15 articles that included 382 EUS-RV cases, the overall success rate of EUS-RV is 81 % with a complication rate of 10 %. In EUS-RV, the bile duct is punctured under EUS guidance and a guidewire is advanced into the duodenum via the papilla. The EUS scope is then switched to a duodenoscope and inserted into the bile duct over the guidewire exiting the papilla, or the guidewire is grasped with forceps and passed through the working channel; the catheter can then be inserted through the papilla over the wire. There are three puncture routes for EUS-RV: transgastric puncture of the intrahepatic bile duct (IHBD), transduodenal puncture of the extrahepatic bile duct (EHBD) via the proximal duodenum (D1), and transduodenal puncture of the EHBD via the second portion of the duodenum (D2). The puncture route for each patient should be selected based on the patient condition. GW selection for EUS-RV is critical, a hydrophilic GW is useful for this procedure. Although EUS-RV is now performed relatively routinely in a few high-volume centers, procedure standardization and the development of exclusive devices for EUS-RV are still underway. The development of exclusive devices for EUS-RV and prospective comparative studies with other salvage methods are needed to truly evaluate the procedure's usefulness and safety.

  18. Evaluation of Snake Bites with Bedside Ultrasonography

    Directory of Open Access Journals (Sweden)

    Josef E Jolissaint

    2018-04-01

    Full Text Available History of present illness: While watering his lawn, a 36-year-old man felt two sharp bites to his bilateral ankles. He reports that he then saw a light brown, 2-foot snake slither away from him. He came to the emergency department because of pain and swelling in his ankles and inability to bear weight. Physical examination revealed bilateral ankle swelling and puncture marks on his left lateral heel and medial right ankle. Palpation, passive flexion and extension elicited severe pain bilaterally. Blood work including prothrombin time (PT, partial thromboplastin time (PTT, international normalized ratio (INR, and fibrinogen were within normal limits. Consultation with Poison Control indicated the snake was likely a copperhead, which is a venomous snake whose bites rarely require antivenin. Significant findings: In this case, ultrasonography of the lateral surface of the left foot revealed soft tissue edema (red arrow and fluid collection (white asterisk adjacent to the extensor tendon (white arrow. The edematous area resembles cobblestones, with hypoechoic areas of fluid spanning relatively hyperechoic fat lobules. The tendon is surrounded by anechoic fluid, expanding the potential space in the sheath. No hyperechoic foreign objects were noted. Discussion: The patient was diagnosed with soft tissue injury and extensor tenosynovitis after a snake envenomation. Snake venom contains metalloproteinases and other enzymatic proteins that cause local tissue edema and necrosis.1 After a snake bite, ultrasound can be used to assess for retained fangs, soft tissue edema, tendon sheath fluid, muscle fasciculation, and injury to deeper musculature that may not be readily apparent on physical exam.2,3 Most patients with tenosynovitis will recover with immobilization of the joint and non-steroidal anti-inflammatory medications.4 Rarely, the tendon may become infected requiring antibiotics and surgical intervention.4 Topics: Ultrasound, snake envenomation

  19. Ultrasonography in Gastroenterology: The Need for Training

    Directory of Open Access Journals (Sweden)

    João Pinto

    2018-02-01

    Full Text Available The use of ultrasonography (US as an imaging modality in medicine has spread across almost every clinical specialty. This diffusion is based on the simplicity, accessibility, portability and affordability of the technique producing real-time high-resolution images using non-ionising radiation. On the other hand, this trend also extended the technique to settings other than healthcare, such as public facilities, private houses or remote sites. This tendency can be observed worldwide, from developing countries to prestigious medical schools and tertiary referral hospitals. Furthermore, point-of-care US (POCUS, i.e., US executed at the patient’s bedside to obtain real-time objective information with diagnostic and clinical monitoring purposes or to guide invasive procedures, has been incorporated in many specialties. In gastroenterology, despite the essential role of endoscopy, clinical practice is highly dependent on non-endoscopic imaging techniques. However, as in other specialties, the indications of US in gastroenterology have been increasing steadily, covering a broad range of conditions. In response to the generalised employment of US by non-radiologists, institutions such as the European Federation of Societies for Ultrasound in Medicine and Biology and the Royal College of Radiologists issued recommendations to ensure high-quality practice. These theoretical and practical requisites include performing a certain number of examinations and mandatory skills in order to achieve certification to execute unsupervised US. Therefore, there is a need for modern gastroenterology to include US as a basic skill in its clinical practice. To ensure the provision of high-quality US, adequate instruction of future specialists should be guaranteed by the gastroenterology departments and required in the residency training programme.

  20. Evaluation of normal masseter muscles on ultrasonography

    International Nuclear Information System (INIS)

    Hwang, Hyoung Zoo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2008-01-01

    To assess the internal echo intensity and morphological variability of masseter muscles on ultrasonography and to establish diagnostic criterion of estimation. Participants consisted of 50 young adults (male 25, female 25) without pathologic conditions and with full natural dentitions. Sonographic examinations were done with real time ultrasound equipment as Logiq 500 (GE Medical Systems, Seoul, Korea) at 3 parts according to lines paralleling with ala-tragus line as reference line. The thickness and area of masseter muscles according to reference line in cross-sectional images were measured at rest and at maximum contraction. The visibility and width of the internal echogenic intensity of the masseter muscles were also assessed and the muscle appearance was classified into 4 types. Data were statistically analyzed by paired t-test and x2-test. 1. When comparing the thickness and area of masseter muscles concerning with gender, there was few significant difference between right and left sides, however, there were significant differences between males and females except for the greatest thickness of left side. 2. The changes of the greatest thickness and the area between rest and maximum contraction showed that the part of the least thickness manifested more increase at maximum contraction. 3. Each part the manifestations of the internal echogenic intensity of the masseter muscles were different depending on the locations. But there was no statistically significance. Changes of muscles thickness with contraction and internal echogenic intensity with locations showed great disparity within the masseter muscles, which will be diagnostic criteria for pathophysiologic and anatomic changes of masseter muscles.

  1. Endoscopic Ultrasonography-Guided Techniques for Accessing and Draining the Biliary System and the Pancreatic Duct.

    Science.gov (United States)

    Rimbaş, Mihai; Larghi, Alberto

    2017-10-01

    When endoscopic retrograde cholangiopancreatography (ERCP) fails to decompress the biliary system or the pancreatic duct, endoscopic ultrasonography (EUS)-guided biliary or pancreatic access and drainage can be used. Data show a high success rate and acceptable adverse event rate for EUS-guided biliary drainage. The outcomes of EUS-guided biliary drainage seem equivalent to percutaneous drainage and ERCP, whereas only retrospective studies are available for pancreatic duct drainage. In this article, revision of the technical and clinical status and the current evidence of interventional EUS-guided biliary and pancreatic duct access and drainage are presented. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. The Diagnostic and Prognostic Value of Ultrasonography in Soccer Players With Acute Hamstring Injuries

    DEFF Research Database (Denmark)

    Petersen, Jesper; Thorborg, Kristian; Nielsen, Michael Bachmann

    2014-01-01

    BACKGROUND: An injury to the hamstring muscle complex is the most common injury in soccer. Ultrasound of acute hamstring injuries is often used as a clinical tool for diagnosing hamstring injuries and guiding players in when they can return to play. PURPOSE: To (1) investigate the characteristic......) to investigate if ultrasonography can be used as a prognostic indicator of time to return to play. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Players from 50 teams participating in 1 of the top 5 Danish soccer divisions were followed in the period from January to December 2008. Of 67 players...

  3. Color doppler sonography in thickened gallbladder wall

    International Nuclear Information System (INIS)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki

    1996-01-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes

  4. Evaluation of lymph node perfusion using continuous mode harmonic ultrasonography with a second-generation contrast agent.

    Science.gov (United States)

    Rubaltelli, Leopoldo; Khadivi, Yeganeh; Tregnaghi, Alberto; Stramare, Roberto; Ferro, Federica; Borsato, Simonetta; Fiocco, Ugo; Adami, Fausto; Rossi, Carlo Riccardo

    2004-06-01

    To evaluate the contribution of continuous mode contrast-enhanced harmonic ultrasonography (CE-HUS) with a second-generation contrast agent to the characterization of superficial lymphadenopathies with respect to conventional ultrasonographic techniques (B-mode and power Doppler). Fifty-six lymph nodes from 45 patients were studied both by conventional techniques and by CE-HUS. The dimensions, intranodal architecture, margins, and location of vessels were evaluated. Subsequently, all the lymph nodes were examined by CE-HUS, and enhancement of echogenicity was evaluated. The diagnoses obtained by means of fine-needle aspiration cytologic examination, surgical biopsy, or both were compared with those obtained by ultrasonography. Of the lymph nodes examined, 30 were benign and 26 were malignant (18 metastases and 8 non-Hodgkin lymphomas). The study using CE-HUS showed intense homogeneous enhancement in 28 of 30 reactive lymph nodes; perfusion defects in 17, of which 15 were neoplastic and 2 were inflammatory; intense but inhomogeneous speckled enhancement in the early arterial phase in 5 cases of lymphoma; and, last, scarce or absent intranodal enhancement in 4 metastases. The specificity, sensitivity, and accuracy of conventional techniques in differentiation between benign and malignant lymph nodes were 76%, 80%, and 78% versus 93%, 92%, and 92.8% for CE-HUS. The increase in correct diagnoses was significant (P = .05) when conventional ultrasonography was tested against CE-HUS. Superficial lymph nodes can be characterized as being neoplastic or benign with a high degree of diagnostic accuracy on the basis of the perfusion characteristics evaluated by CE-HUS. This technique has been shown to afford a higher degree of accuracy than currently obtainable by any other ultrasonographic technique.

  5. Gestational ultrasonography and Dopplerfluxometry in capuchin monkeys (Sapajus apella) zoometric.

    Science.gov (United States)

    Miranda, S A; Leão, D L; Oliveira, K G; Sodré, I S; Domingues, S F S

    2018-03-01

    The objectives of the current study were as follows: 1) to evaluate blood flow in the uterine (UA) and umbilical (Uma) arteries in pregnant capuchin monkeys by measuring the resistive index (RI) and pulsatility index (PI); 2) to determine the presence or absence of the early diastolic notch and diastolic flow in the UA and Uma flow waveforms, respectively; 3) to perform conceptus echobiometry for fetal growth assessment during pregnancy; 4) to describe the moment that the fetal organs were initially observed; and 5) to determine when the diagnosis of fetal gender is possible. Seven healthy, sexually mature female Sapajus apella were examined in Weeks -20 to -1 before whelping (whelping Week 0). Triplex Doppler was used to assess the blood flow and fetal heart rate, and B-mode ultrasonography was used to assess the fetal organs and conceptus measurements, including the gestational sac latero-lateral longitudinal (LLL) and latero-lateral transversal (LLT), the crown rump length (CRL), biparietal diameter (BPD), occipito-frontal diameter (OFD), head circumference (HC), abdominal circumference (AC), femur length (FL) and fetal organ. All the pregnancies ended with a normal whelping and the birth of a live newborn. Prior to whelping, all conceptus dimensions increased significantly, whereas the RI and PI of both the UA and Uma decreased significantly. For the UA, the RI and PI were (mean ± SEM) 0.835 ± 0.017 and 2.157 ± 0.129, 0.808 ± 0.008 and 1.920 ± 0.041, and 0.761 ± 0.006 and 1.759 ± 0.036 on periods -3, -2 and -1, respectively. For the Uma, the RI and PI were 0.97 ± 0.01 and 2.50 ± 0.02 at Week -17 and were 0.64 ± 0.02 and 0.98 ± 0.04 at Week -1, respectively. The complete disappearance of the early diastolic notch in the UA, and the complete appearance of diastolic flow in the Uma occurred on Week -1 and Week -11, respectively. Linear regression analyses regarding the relationship of the weeks before whelping (WBW) with the

  6. Transvaginal ultrasonography in first trimester of pregnancy and its comparison with transabdominal ultrasonography

    Directory of Open Access Journals (Sweden)

    Aneet Kaur

    2011-01-01

    Full Text Available Objectives : Examination of pregnant women in the first trimester with transvaginal ultrasonography with the aim to study various fetal development markers, e.g., gestation sac, yolk sac, fetal heart motion, CRL length, and fetal anatomy in both normal and abnormal pregnancies. Comparative evaluation of transvaginal ultrasonography vis-ΰ-vis transabdominal scanning in the study of first trimester of pregnancy and its complications. To assess the relative merits and demerits of transvaginal ultrasonography in comparison with the transabdominal technique. Materials and Methods : The study will be conducted on 50 females patients during the first trimester of pregnancy. The study population will consist of both normal and abnormal pregnancies. These patients will be included on the basis of suspicion of or proven pregnancy of duration up to 12 weeks from LMP. The evaluation of the patients will include the following: Record of patients obstetrical history and clinical examination, record of pregnancy test and relevant investigations, ultrasonic examination of pregnancy. (a Transabdominal ultrasound scanning will be done with moderately distended bladder by using real time scanners with low frequency probe (3/3.5 MHz; (b transvaginal sonography will be done with the real-time sector scanner using high-frequency endovaginal probe (5/7.5 MHz, after the patient voids urine. Relevant images will be taken by using the multiformat automatic camera. Results and Conclusions : In the study of 46 normal intrauterine pregnancies, TVS showed additional information in 36 patients (78.3% as compared to TAS, in detection of gestation sac, yolk sac, double bleb sign, or better visualization of embryonic anatomy. In the abnormal pregnancy (n=17, TVS provided more information in 11 cases (64.9%, which included detection of embryonic demise, yolk sac, double bleb sign, or subchorionic hemorrhage. Regarding ectopic gestations (n=7, TVS gave additional information in 5

  7. Evaluation of abdominal trauma by computed tomography and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Kim, Sang Jin; Lee, Jong Tae; Yoo, Hyung Sik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1986-06-15

    Out of 75 patients who were admitted to our hospital because of abdominal trauma and were undergone the procedures such as ultrasonography and/or CT scan within 24 hours of abdominal trauma due to suspected abdominal organ injury. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. 1. In the abdominal organ injury, solid organ injury consists of 8 cases of spleen laceration, 1 of splenic subcapsular hematoma, 7 of hepatic laceration, 7 of pancreas laceration, 3 of renal laceration, and 3 of subcapsular hematoma of kidney. 2. In addition, there were 7 bowel and/or mesenteric laceration, 2 diaphragmatic hernia, and 1 urethral rupture. 3. 2 cases of retroperitoneal hematoma and 1 case in which hemo peritoneum occurred without abdominal organ injury were confirmed by follow-up CT or ultrasonography. 4. In all of the 4 patients with multiple organ injury, pancreatic laceration was associated. 5. In abdominal trauma patients, ultrasonography or CT can be used to survey rapidly the entire abdomen for possible associated injury, and be of great help to clinicians in identifying the patients who need immediate surgery or in minimizing the incidence of unnecessary emergency abdominal exploration.

  8. Evaluation of abdominal trauma by computed tomography and ultrasonography

    International Nuclear Information System (INIS)

    Lee, Do Yun; Kim, Sang Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1986-01-01

    Out of 75 patients who were admitted to our hospital because of abdominal trauma and were undergone the procedures such as ultrasonography and/or CT scan within 24 hours of abdominal trauma due to suspected abdominal organ injury. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. 1. In the abdominal organ injury, solid organ injury consists of 8 cases of spleen laceration, 1 of splenic subcapsular hematoma, 7 of hepatic laceration, 7 of pancreas laceration, 3 of renal laceration, and 3 of subcapsular hematoma of kidney. 2. In addition, there were 7 bowel and/or mesenteric laceration, 2 diaphragmatic hernia, and 1 urethral rupture. 3. 2 cases of retroperitoneal hematoma and 1 case in which hemo peritoneum occurred without abdominal organ injury were confirmed by follow-up CT or ultrasonography. 4. In all of the 4 patients with multiple organ injury, pancreatic laceration was associated. 5. In abdominal trauma patients, ultrasonography or CT can be used to survey rapidly the entire abdomen for possible associated injury, and be of great help to clinicians in identifying the patients who need immediate surgery or in minimizing the incidence of unnecessary emergency abdominal exploration.

  9. Evaluation of breast symptoms with mammography and ultrasonography

    Directory of Open Access Journals (Sweden)

    Emine Devolli Disha

    2011-12-01

    Full Text Available Introduction: Aim of the study was to discern which are more frequent symptoms presented in malign and benign masses diagnosed by mammography and ultrasonography.Methods: Our study group consisted of 546 female patients, with breast symptoms such as palpable lumps (40.8%, pain in the breast (26%, localized lumpiness or nodularity (13.7%, nipple retraction (11.2%, nipplebloody discharge (5.1% and redness and swelling of the breast (3.1%. All 546 patients were examined by ultrasonography and mammography. Biopsy was performed according to the findings of mammography and ultrasonography.Results: In breast cancer detection ultrasonography showed an efficiency of 79.4% compared to 55.0% for mammography in detecting breast lump, in the case of nipple retraction mammography showed an efficiency of 89.1% compared to 80.4% for ultrasound, while the lowest efficiency for mammography was in the cases with localized lumpiness or nodularity 17.1% compared to 45.7% for ultrasound. In detecting fibrocystic changes where the most common symptoms was pain, ultrasonography showed an efficiency of 99.3 % compared to 84.2 % for mammography.Conclusions: Our study confirmed that breast lumps are detectable in the majority of patients with breast cancer. The most frequent symptoms in patient with benign lesions were pain or localized discomfort. The diagnostic accuracy for carcinomas of the breast and for benign lesions according to symptoms was higher for ultrasound than for mammography.

  10. Color doppler imaging of subclavian steal phenomenon

    International Nuclear Information System (INIS)

    Cho, Nari Ya; Chung, Tae Sub; Kim, Jai Keun

    1997-01-01

    To evaluate the characteristic color doppler imaging of vertebral artery flow in the subclavian steal phenomenon. The study group consisted of eight patients with reversed vertebral artery flow proved by color Doppler imaging. We classified this flow into two groups:(1) complete reversal;(2) partial reversal, as shown by Doppler velocity waveform. Vertebral angiography was performed in six of eight patients;color Doppler imaging and angiographic findings were compared. On color Doppler imaging, all eight cases with reversed vertebral artery flow showed no signal at the proximal subclavian or brachiocephalic artery. We confirmed shunting of six cases by performing angiography from the contralateral vertebral and basilar artery to the ipsilateral vertebral artery. On the Doppler spectrum, six cases showed complete reversal and two partial reversal. On angiography, one partial reversal case showed complete occlusion of the subclavian artery with abundant collateral circulation of muscular branches of the vertebral artery. On color Doppler imaging, a reversed vertebral artery suggests the subclavian steal phenomenon. In particular, partial reversal waveform may reflect collateral circulation

  11. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  12. Doppler Velocity Signatures of Idealized Elliptical Vortices

    Directory of Open Access Journals (Sweden)

    Wen-Chau Lee

    2006-01-01

    Full Text Available Doppler radar observations have revealed a class of atmospheric vortices (tropical cyclones, tornadoes, dust devils that possess elliptical radar reflectivity signatures. One famous example is Typhoon Herb (1996 that maintained its elliptical reflectivity structure over a 40-hour period. Theoretical work and dual-Doppler analyses of observed tropical cyclones have suggested two physical mechanisms that can explain the formation of two types of elliptical vortices observed in nature, namely, the combination of a circular vortex with either a wavenumber two vortex Rossby wave or a deformation field. The characteristics of these two types of elliptical vortices and their corresponding Doppler velocity signatures have not been previously examined.

  13. Preliminary simulation study of doppler reflectometry

    International Nuclear Information System (INIS)

    Ishii, Yuta; Hojo, Hitoshi; Yoshikawa, Masashi; Ichimura, Makoto; Haraguchi, Yusuke; Imai, Tsuyoshi; Mase, Atsushi

    2010-01-01

    A preliminary simulation study of Doppler reflectometry is performed. The simulations solve Maxwell's equations by a finite difference time domain (FDTD) code method in two dimensions. A moving corrugated metal target is used as a plasma cutoff layer to study the basic features of Doppler reflectometry. We examined the effects of the full width at half maximum (FWHM) of the electromagnetic waves and the corrugation depth of the metal target. Furthermore, the effect of a nonuniform plasma is studied using this FDTD analysis. The Doppler shift and velocity are compared with those obtained from FDTD analysis of a uniform plasma. (author)

  14. Cholescintigraphy and ultrasonography in patients suspected of having acute cholecystitis

    DEFF Research Database (Denmark)

    Lauritsen, K B; Sommer, W; Hahn, L

    1988-01-01

    The diagnostic power of combined cholescintigraphy and ultrasonography was tested in 67 patients suspected of having acute cholecystitis; of these, 42 (63%) had acute cholecystitis. The predictive value of a positive scintigraphy (PVpos) was 95% and that of a negative (PVneg) was 91% (n = 67......). The PVpos and PVneg of ultrasonography were 89% and 75%, respectively (n = 54), and these values did not achieve statistical significance when compared with those for scintigraphy. Inconclusive tests were 10% and 11%, respectively, but in no patient were both scintigraphy and ultrasonography inconclusive...... that in patients suspected of having acute cholecystitis cholescintigraphy should be the first diagnostic procedure performed. If the scintigraphy is positive, additional ultrasonographic detection of gallstones makes the diagnosis almost certain. If one diagnostic modality is inconclusive, the other makes a fair...

  15. Ultrasonography and radiography of the canine postpartum uterus

    International Nuclear Information System (INIS)

    Pharr, J.W.; Post, K.

    1992-01-01

    A vulvovaginal discharge following parturition in a bitch is often a cause of concern to owners and clinicians, especially if whelping was complicated in any way. Ultrasonography could potentially distinguish between normal and abnormal postpartum uterine states because the uterine wall and luminal contents can be imaged in detail. Five normal bitches were examined to determine the normal ultrasonographic appearance of the postpartum uterus and the sensitivity of ultrasonography in detecting the involuting uterus, comparing this sensitivity with that of radiography. Ultrasonography was done at 1, 4, 8, 12, 18 and 24 days postpartum, radiography at 1, 4, 8, 12 and 18 days postpartum. By 12 days postpartum, the uterus could not be seen on radiographs, while at 24 days postpartum the uterus was still sonographically identifiable. The ultrasonographic characteristics of the involuting uterus are described

  16. The diagnostic value of ultrasonography in the gyneocological emergency

    International Nuclear Information System (INIS)

    Su Hui; Chen Fanghua; Peng Xiulan

    2006-01-01

    Objective: To evaluate the ultrasonography in the diagnosis and differential diagnosis of gynecologic emergency. Methods: 138 patients suffered from gynecologic emergency were examined with ultrasonography. The images were retrospectively reviewed and compared with pathologic or clinical results. Results: The total correct diagnostic rate was 89.1%. Among 138 cases of gynecologic emergency, there were 45 cases of ectopic pregnancy, 27 cases of ruptured corpus luteum, 24 cases of torsion of ovarian cyst, and 42 cases of acute pelvic inflammation. The correct diagnostic rates were 91.1%, 81.5%, 87.5%, 92.2%, respectively. Conclusion: The ultrasonography plays an important role in the diagnosis of gynecological emergency. When the US findings were not typical, the clinical history, symptoms and HCG level should be considered in order to avoid misdiagnosis. (authors)

  17. Is pneumoperitoneum the terra ignota in ultrasonography?

    Directory of Open Access Journals (Sweden)

    Andrzej Smereczyński

    2015-06-01

    Full Text Available In most cases, pneumoperitoneum is caused by gastrointestinal perforation, which usually requires surgical treatment. Many authors believe that ultrasound imaging of pneumoperitoneum is at least as effective as conventional radiography, or even that its efficacy is superior. In such a situation, it is imperative to make this modality one of the main tools in the diagnostic arsenal of emergency medicine. This is the main aim of this paper. First, ultrasound anatomy of so-called thoracic-abdominal border is discussed. The equipment requirements emphasize that the diagnostic process can be conducted with the simplest portable US scanner, even without the Doppler mode. The technique of a US examination, the aim of which is to detect, free air in the peritoneal cavity is also simple and conducted with the patients lying down, either in the supine or lateral position. A convex transducer with the frequency of 3.5–5 MHz is applied above the lower intercostal spaces on the right and left side, to the epigastric region below the xiphoid process and in various sites of the abdominal wall. The most effective examination, however, is conducted in the left lateral position via the right intercostal spaces. The differential diagnosis on the right side under the diaphragm should include the presence of a subdiaphragmatic abscess with gas and a hepatic abscess with a similar content as well as transposition of the colon in between the diaphragm and the liver (Chilaiditi syndrome. It seems that the inclusion of a US examination to the E-FAST method in order to detect free gas in the peritoneal cavity is justified since it is a sign of gastrointestinal perforation in numerous cases, and is clinically as relevant as the presence of free fluid.

  18. Current recommendations for the study of carotid stenosis by doppler ultrasound and other imaging techniques

    International Nuclear Information System (INIS)

    Perez Matamoros, Angelica

    2012-01-01

    Ischemic cerebrovascular disease has been one of the most frequent causes of death from chronic disease, as well as cause of long-term disabilities, in both the United States, and in Latin American countries during recent years. It is therefore, important to know about it. An updated review of international recommendations to the Costa Rican health system is performed for carotid imaging study in patients at risk of accidents and ischemic cerebrovascular disease; with special emphasis on carotid Doppler ultrasonography, due to its wide availability in the medical field Costa Rican. Furthermore, certain relevant concepts of other imaging techniques currently available are listed to determine the appropriate choice of each method according to the individual patient's condition, such as conventional angiography and tomographic angiography [es

  19. Assessment of total placenta previa by magnetic resonance imaging and ultrasonography to detect placenta accreta and its variants.

    Science.gov (United States)

    Peker, Nuri; Turan, Volkan; Ergenoglu, Mete; Yeniel, Ozgur; Sever, Ahmet; Kazandi, Mert; Zekioglu, Osman

    2013-03-01

    To evaluate the importance of ultrasonography (US) and magnetic resonance imaging (MRI) in detecting placental adherence defects. Patients diagnozed with total placenta previa (n = 40) in whom hysterectomy was performed due to placental adherence defects (n = 20) or in whom the placenta detached spontaneously after a Cesarean delivery (n = 20) were included into the study between June 2008 and January 2011, at the Department of Obstetrics and Gynecology Ege University (lzmir Turkey). Gray-scale US was used to check for any placental lacunae, sub-placental sonolucent spaces or a placental mass invading the vesicouterine plane and bladder Intra-placental lacunar turbulent blood flow and an increase in vascularization in the vesicouterine plane were evaluated with color Doppler mode. Subsequently all patients had MRI and the results were compared with the histopathologic examinations. The sensitivity of MRI for diagnosis of placental adherence defects before the operation was 95%, with a specificity of 95%. In the presence of at least one diagnostic criterion, the sensitivity and specificity of US were 87.5% and 100% respectively, while the sensitivity of color Doppler US was 62.5% with a specificity of 100%. Currently MRI appears to be the gold standard for the diagnosis of placenta accreta. None of the ultrasonographic criteria is solely sufficient to diagnose placental adherence defects, however they assist in the diagnostic process.

  20. [Abdominal ultrasonography in patients with diabetes mellitus. Part 1: Liver].

    Science.gov (United States)

    Jenssen, C; Pietsch, C; Gottschalk, U; Barreiros, A P; Teufel, A; Cui, X W; Dietrich, C F

    2015-04-01

    In patients with diabetes mellitus, abdominal ultrasonography is the appropriate diagnostic technique to detect and to follow-up secondary and accompanying diseases of the liver, the kidneys, the pancreas, the gastrointestinal tract and of abdominal vessels. Moreover, pancreatic and hepatic diseases may be realized which are of etiological importance for diabetes mellitus. Based on a systematic survey of the published literature, this review in 3 parts will describe the value of abdominal ultrasonography in patients with diabetes mellitus. Part 1 deals with the diagnostic relevance and particular findings of ultrasonographic methods in hepatic manifestations and complications of diabetes mellitus. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Traumatic Lumbar Hernia Diagnosed by Ultrasonography: A Case Report

    International Nuclear Information System (INIS)

    Lee, Kwang Lae; Yim, Yoon Myung; Lim, Oh Kyung; Park, Ki Deok; Choi, Chung Hwan; Lee, Ju Kang

    2009-01-01

    Traumatic lumbar hernia describes the extrusion of intraperitoneal or extraperitoneal contents through a defect in the posterolateral abdominal wall caused by a trauma. This is a rare entity and usually diagnosed by computed tomography. A 64-year-old male received an injury on his cervical spinal cord after an accident in which he fell down. He complained of a mass on his left posterolateral back area. We diagnosed the mass as a traumatic lumbar hernia by ultrasonography and confirmed it by computed tomography. We conclude that the ultrasonography can be a useful diagnostic tool for traumatic lumbar hernia

  2. Traumatic Lumbar Hernia Diagnosed by Ultrasonography: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang Lae; Yim, Yoon Myung; Lim, Oh Kyung; Park, Ki Deok; Choi, Chung Hwan; Lee, Ju Kang [Gachon University of Medicine and Science, Incheon (Korea, Republic of)

    2009-12-15

    Traumatic lumbar hernia describes the extrusion of intraperitoneal or extraperitoneal contents through a defect in the posterolateral abdominal wall caused by a trauma. This is a rare entity and usually diagnosed by computed tomography. A 64-year-old male received an injury on his cervical spinal cord after an accident in which he fell down. He complained of a mass on his left posterolateral back area. We diagnosed the mass as a traumatic lumbar hernia by ultrasonography and confirmed it by computed tomography. We conclude that the ultrasonography can be a useful diagnostic tool for traumatic lumbar hernia

  3. Paediatric ultrasonography of the liver, hepatobiliary tract and pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Rijn, R.R. van, E-mail: r.r.vanrijn@amc.uva.nl [Department of Radiology, Emma Children' s Hospital – Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Nievelstein, R.A.J. [Department of Radiology, Wilhelmina Children' s Hospital – University Medical Center, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2014-09-15

    In the field of paediatric radiology ultrasonography (US) is the most versatile imaging tool available. Children in general, by virtue of their body composition, are excellent candidates for US exams in whom abdominal anatomy and pathology can be visualised in great detail. The fact that during the US study a clinical history can be obtained strongly adds to the value of the US exam. This does require investment in time and expertise and ideally a paediatric radiologist performing the exam. In this review the role of ultrasonography (US) of the liver, biliary tract and pancreas in children is discussed.

  4. Ultrasonography of hydronephrosis in the newborn: A practical review

    International Nuclear Information System (INIS)

    Choi, Young Hun; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One

    2016-01-01

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn

  5. Ultrasonography of hydronephrosis in the newborn: a practical review

    Science.gov (United States)

    2016-01-01

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn. PMID:27156562

  6. Ultrasonography of hydronephrosis in the newborn: A practical review

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Hun; Cheon, Jung Eun; Kim, Woo Sun; Kim, In One [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Children' s Hospital, Seoul (Korea, Republic of)

    2016-07-15

    Widespread use of fetal ultrasonography is accompanied by more frequent detection of antenatal hydronephrosis. Therefore, sonographic evaluation of neonates with a history of antenatal hydronephrosis is becoming more widespread. As an initial postnatal non-invasive imaging modality, ultrasonography is used to screen for persistence of hydronephrosis, determine the level and severity of obstruction, and contribute to appropriate diagnosis and treatment. This review aims to provide a practical overview of the sonographic evaluation of neonatal hydronephrosis and to describe the sonographic findings of conditions associated with hydronephrosis in the newborn.

  7. Contrast-enhanced power Doppler US in the characterization of renal masses

    International Nuclear Information System (INIS)

    Ascenti, G.; Zimbaro, G.; Mazziotti, S.; Visalli, C.; Racchiusa, S.; Vinci, S.; Scribano, E.

    2000-01-01

    Purpose of this work is to report the results of a prospective study investigating the potentials of contrast-enhanced power Doppler in the diagnosis of expansive renal lesions. From 1997 to October 30, 1999, it was studied the case of 59 expansive renal lesions (28 malignant, 31 benign) in 48 patients (mean age 55 years, range 10-79) with power Doppler US before and after the administration of an echo-enhancing agent (Levovist, Schering AG, Berlin Germany). Were found 5 patterns of vascular architecture of the lesions, both before and after contrast agent administration, following the classification by Jinzaki e Coll. Power Doppler US showed vascular structures in 34 patients. The administration of Levovist revealed vessels in 12/25 lesions which had none at baseline studies and in 6 cases vascularity was particularly evident. Color signals were enhanced in all the 34 vascularized lesions, which allowed better definition of vascular patterns. The characterization of vascular patterns with baseline power Doppler US helped improve diagnostic accuracy compared to gray-scale US (58% versus 32%) for hyperechoic lesions, complex cysts and pseudomasses. Independent of contrast agent administration, the integration of gray-scale and power Doppler modes increased diagnostic accuracy even further (76% correct diagnoses). In our series, the US contrast agent did not increase the diagnostic accuracy of power Doppler in the differential diagnosis of hyperechoic renal lesions; conversely, Levovist can be advantageous for the characterization of suspected pseudomasses and complex cysts [it

  8. The Doppler Ultrasonographic Evaluation of Hemodynamic Changes in Hepatic Vascular Structures in Patients with Hepatosteatosis

    International Nuclear Information System (INIS)

    Karasin, Mehmet; Tokgoz, Ozlem; Serifoglu, İsmail; Oz, İlker; Erdem, Oktay

    2014-01-01

    The hemodynamic changes in hepatic vascular structures of hepatosteatosis patients were examined using Doppler ultrasonography. Ninety hepatosteatosis patients, classified as mild, moderate or severe, and 30 healthy volunteers were included in this 120-person study. The height, weight, liver size, blood lipids and blood liver function tests of the subjects were measured. Those values were compared in the patient and control groups. In the patient and control groups, color duplex Doppler ultrasonography was used to examine portal vein peak velocity, portal vein flow volume, hepatic artery resistive index (RI), hepatic artery pulsatility index (PI) and hepatic artery flow volume. Similarly to the degree of hepatosteatosis, increases in body mass index, liver size, liver enzyme levels and blood lipid levels were statistically significant (p<0.05). While the difference in portal vein peak velocity in the hepatosteatosis and control groups was not statistically significant, there was an increasing reduction in the degree of steatosis (p>0.05). As the degree of hepatosteatosis increased, there was a reduction in hepatic artery flow volume, portal vein flow volume and total flow volume that was not statistically significant. In the mild hepatosteatosis group, hepatic artery RI and PI values were statistically significantly lower than in the other groups (p<0.05). In the severe hepatosteatosis group, although the hepatic artery RI and PI values were not statistically significant, there was a minimal increase compared to the other groups. It is believed that those results were caused by a reduction in liver compliance and hepatic vascular compliance, in addition to resistance increase in vascular structures

  9. The assessment of neurovascular coupling with the Addenbrooke's Cognitive Examination: a functional transcranial Doppler ultrasonographic study.

    Science.gov (United States)

    Beishon, Lucy C; Williams, Claire A L; Panerai, Ronney B; Robinson, Thompson G; Haunton, Victoria J

    2018-03-01

    Cerebrovascular dysfunction occurs early in dementia and can be identified by transcranial Doppler ultrasonography (TCD). Few studies have examined cerebral blood flow velocity (CBFv) responses to a detailed cognitive battery. This study aimed to characterize all CBFv responses, and the effect of hemispheric dominance, to the Addenbrooke's Cognitive Examination (ACE-III) in healthy volunteers. Forty volunteers underwent continuous bilateral TCD, beat-to-beat blood pressure (MAP; Finapres), heart rate (HR; electrocardiogram), and end-tidal CO 2 (ETCO 2 ; capnography) monitoring. After a 5-min baseline period, all tasks from the ACE-III were performed in 3 sections (A: attention, fluency, memory; B: language; C: visuospatial, memory). Data are population mean normalized percentage (PM%) change from a 20-s baseline period before task initiation. Forty bilateral data sets were obtained (27 women, 37 right-hand dominant). All paradigms produced a sharp increase in CBFv in both dominant (PM% range: 3.29 to 9.70%) and nondominant (PM% range: 4.34 to 11.63%) hemispheres at task initiation, with associated increases in MAP (PM% range: 3.06 to 16.04%). ETCO 2 did not differ significantly at task initiation (PM% range: -1.1 to 2.4%, P > 0.05). HR differed significantly across A and C tasks at initiation (PM% range: -1.1 to 2.4%, P cognitively impaired population. NEW & NOTEWORTHY This study is the first to provide a normative data set of cerebral blood flow velocity (CBFv) responses to a complete cognitive assessment (Addenbrooke's Cognitive Examination, ACE-III) in a large sample ( n = 40) of healthy volunteers. All tasks produced peak and sustained increases in CBFv to different extents. The ACE-III is a feasible tool to assess neurovascular coupling with transcranial Doppler ultrasonography. These data can be used to inform the most appropriate cognitive task to elicit CBFv responses for future studies.

  10. Value of sonomammography utilizing color Doppler technique in qualification of breast cancer patients for sentinel node identification

    International Nuclear Information System (INIS)

    Basta, P.; Wadowska-Jaszczynska, K.; Krysztopowicz, W.; Przybylska, P.; Wisniowski, Z.

    2007-01-01

    Sentinel node identification has become a standard procedure in the management of breast cancer. This procedure requires involvement of a multidisciplinary team and is rather costly. Ultrasonography (USG) of axillary lymph nodes is a method that gives hope for improving the quality of qualification of patients for the procedure. Eighty patients with grade I and II breast cancers underwent sentinel node identification followed by axillary lymphadenectomy. Pre-operative ultrasonography was employed to assess axillary lymph nodes, using the morphological and vascular characteristics as predictors of the presence of lymph node metastases. Sensitivity of sentinel node identification reached 89.3%, specificity - 100%, positive predictive value - 100%, negative predictive value - 93.5%, percentage of false negative results - 10.7%. Sensitivity of USG reached 68.75 %, and specificity - 70.31%. In the group of patients in whom the sentinel node was identified, the sensitivity of the method was 69.23 %, and specificity - 72.41%. Preoperative axillary lymph node ultrasonography in breast cancer patients, utilizing color Doppler technique, allows better selection of patients for sentinel node identification procedure. (author)

  11. Ultrasonography and computer tomography in the diagnosis of certain abdominal diseases

    International Nuclear Information System (INIS)

    Wawrzynek, Z.

    1981-01-01

    Ultrasonography and computer tomography in the diagnosis of digestive tract and spleen diseases as well as traumas are compared. It is concluded that ultrasonography is nearly as usefull as computer tomography. (author)

  12. Killian-Jamieson Diverticulum Mimicking a Thyroid Nodule on Ultrasonography: A Case Report

    International Nuclear Information System (INIS)

    Kim, Eun Soo; Lee, Kwan Seop; Yoon, Hoi Soo; Jeon, Eui Yong; Hwang, Hee Sung; Koh, Sung Hye; Kim, Min Jeong; Jang, Kyung Mi; Lee, Myung Jun; Lee, Yul

    2007-01-01

    Thyroid ultrasonography is widely used for diagnosis and cytologic evaluation of thyroid nodules. We encountered a case of Killian-Jamieson diverticulum, which was differentiated from a thyroid nodule using ultrasonography

  13. Noncoherent Doppler tracking: first flight results

    Science.gov (United States)

    DeBoy, Christopher C.; Robert Jensen, J.; Asher, Mark S.

    2005-01-01

    Noncoherent Doppler tracking has been devised as a means to achieve highly accurate, two-way Doppler measurements with a simple, transceiver-based communications system. This technique has been flown as an experiment on the Thermosphere, Ionosphere, Mesosphere, Energetics and Dynamics (TIMED) spacecraft, (launched 7 December 2001), as the operational technique for Doppler tracking on CONTOUR, and is baselined on several future deep space missions at JHU/APL. This paper reports on initial results from a series of successful tests of this technique between the TIMED spacecraft and NASA ground stations in the Deep Space Network. It also examines the advantages that noncoherent Doppler tracking and a transceiver-based system may offer to small satellite systems, including reduced cost, mass, and power.

  14. Doppler coefficient measurements in Zebra Core 5

    International Nuclear Information System (INIS)

    Baker, A.R.; Wheeler, R.C.

    1965-11-01

    Measurements using a central hot loop in Zebra Core 5 are described. Results are given for the Doppler coefficients found in a number of assemblies with PuO 2 and 16% PuO 2 /84% depleted UO 2 pins, loaded with different combinations of steel, sodium or void pins. The mixed oxide results are in general about 20% more negative than was calculated using the FD2 data set, but agreement is good if the plutonium contributions in the calculations are omitted. The small positive Doppler coefficient calculated for Pu239 was not observed, and two measurements indicated instead a small negative effect. The Doppler effect in the mixed oxide systems was found to vary approximately as 1/T. The results from the empty loop and non-fissile assemblies indicate either a small negative Doppler effect in steel or alternatively the presence of an unexplained expansion effect. (author)

  15. Prospective comparative assessment of ultrasonography and ...

    African Journals Online (AJOL)

    for the sensitivity and specificity of US and laparoscopy. Results Our results ... in infants below 1 year of age [13]. Evidence-based ... Toki's classification as seen among our patients. ... been evaluated earlier, the age group tested in this study.

  16. Prevalence of carotid artery calcifications detected on panoramic radiographs and confirmed by Doppler ultrasonography: Their relationship with systemic conditions

    Directory of Open Access Journals (Sweden)

    Thalita Queiroz Abreu

    2015-01-01

    Conclusions: CACs can be detected in PRJs, and are more frequent in common carotid arteries. No significant associations were detected between the presence of unilateral or bilateral CAC in PRJ and hypertension, diabetes, or obesity.

  17. Doppler ultrasonography of the anterior knee tendons in elite badminton players: colour fraction before and after match

    DEFF Research Database (Denmark)

    Kønig, Merete Juhl; Torp-Pedersen, S; Boesen, Morten Ilum

    2010-01-01

    Anterior knee tendon problems are seldom reported in badminton players although the game is obviously stressful to the lower extremities.......Anterior knee tendon problems are seldom reported in badminton players although the game is obviously stressful to the lower extremities....

  18. Use of translabial three-dimensional power Doppler ultrasound for cervical assessment before labor induction.

    Science.gov (United States)

    Esin, Sertac; Yirci, Bulent; Yalvac, Serdar; Kandemir, Omer

    2017-07-26

    To compare translabial three-dimensional (3D) power Doppler ultrasound with Bishop score and transvaginal ultrasound measurements for cervical assessment before induction of labor with dinoprostone or cervical ripening balloon. Translabial cervical volume and length, vascularization indices and transvaginal cervical length were measured. Results were compared among women who had vaginal delivery at 24 h or less and more than 24 h after the insertion of the dinoprostone vaginal insert or cervical ripening balloon and among women who had vaginal delivery and cesarean delivery for failure to go into labor or failure to progress. There was no correlation between the time to delivery after a ripening agent was applied and translabial cervical volume, translabial cervical length, vascularization index (VI), flow index (FI), vascularization flow index (VFI), transvaginal cervical length and Bishop scores. The ultrasonographic measurements were no different among women who had vaginal delivery at 24 h or less and more than 24 h and among women who had vaginal delivery and cesarean delivery for failure to go into labor or failure to progress. In this study, we failed to demonstrate the superiority of translabial 3D ultrasonography over Bishop score and transvaginal ultrasonography for predicting the success of induction of labor.

  19. Applications of Doppler in the first trimester

    International Nuclear Information System (INIS)

    Taylor, K.J.W.; Ramirez, B.; Grannum, P.

    1986-01-01

    Fifty patients have been studied by duplex Doppler US imaging in the first trimester. In normal gestations, luteal flow, characterized by a low pulsatility index (PI), can be seen in at least one ovary. Failure to detect luteal flow indicates a nonviable pregnancy. Six ectopic pregnancies demonstrated luteal flow and extrauterine heartbeat, detected by Doppler US. High PI values in the uterine artery are seen in the first trimester. Low PI values in the uterine arteries were found in patients with trophoblastic disease

  20. De-Dopplerization of Acoustic Measurements

    Science.gov (United States)

    2017-08-10

    accurate measurement of aircraft location to resample the time signal to account for the compression and expansion of acoustic wavefronts. Correcting...AFRL-RH-WP-TR-2017-0043 DE-DOPPLERIZATION OF ACOUSTIC MEASUREMENTS Frank Mobley, PhD 711 HPW/RHCB Wright-Patterson AFB OH...TITLE AND SUBTITLE DE-DOPPLERIZATION OF ACOUSTIC MEASUREMENTS 5a. CONTRACT NUMBER In-House 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER

  1. High-resolution ultrasonography in assessment of nail-related disorders.

    Science.gov (United States)

    Singh, R; Bryson, D; Singh, H P; Jeyapalan, K; Dias, J J

    2012-09-01

    Disorders of the nail can pose a diagnostic challenge, and non-invasive imaging is frequently required to clarify diagnosis and delineate anatomy pre-operatively. We explored the use of high-resolution ultrasonography in the assessment of patients with nail disorders attending orthopaedic hand clinics. A search of a university teaching hospital musculoskeletal radiology database identified 36 patients (mean age 54.2 years) where ultrasonography was used to assess nail-related disorders between April 2003 and January 2007. Clinical, surgical and histological findings were correlated in these cases with ultrasound reports. Ultrasound findings correlated with the provisional diagnosis in 20 (61%) of 33 patients and provided a diagnosis in 3 patients where a provisional diagnosis was unavailable. In 7 of the 13 cases where the clinical diagnosis differed from ultrasound findings, a lump originally diagnosed as cystic in origin was shown to be solid on ultrasound. Different nail pathologies showed different characteristics on ultrasonography, including differences in vascularity, echogenicity, changes in nail structure/shape and extension into the nail bed, matrix, fold or evidence of bony erosion. The ultrasound findings correlated with histological analysis and intra-operative assessment in 10 of 15 patients who underwent operative treatment. Ultrasound provides important information on the anatomy of the nail apparatus and can differentiate solid and cystic lesions. It can be used as a diagnostic tool and can therefore help in pre-operative planning of nail-related disorders. In our series ultrasound supported or improved upon the clinical diagnosis in 31 (86%) out of the 36 patients presenting with nail-related disorders.

  2. Online transcranial Doppler ultrasonographic control of an onscreen keyboard

    Directory of Open Access Journals (Sweden)

    Jie eLu

    2014-04-01

    Full Text Available Brain-computer interface (BCI systems exploit brain activity for generating a control command and may be used by individuals with severe motor disabilities as an alternative means of communication. An emerging brain monitoring modality for BCI development is transcranial Doppler ultrasonography (TCD, which facilitates the tracking of cerebral blood flow velocities associated with mental tasks. However, TCD-BCI studies to date have exclusively been offline. The feasibility of a TCD-based BCI system hinges on its online performance. In this paper, an online TCD-BCI system was implemented, bilaterally tracking blood flow velocities in the middle cerebral arteries for system-paced control of a scanning keyboard. Target letters or words were selected by repetitively rehearsing the spelling while imagining the writing of the intended word, a left-lateralized task. Undesired letters or words were bypassed by performing visual tracking, a non-lateralized task. The keyboard scanning period was 15s. With 10 able-bodied right-handed young adults, the two mental tasks were differentiated online using a Naïve Bayes classification algorithm and a set of time-domain, user-dependent features. The system achieved an average specificity and sensitivity of 81.44 ± 8.35% and 82.30 ± 7.39%, respectively. The level of agreement between the intended and machine-predicted selections was moderate (=0.60. The average information transfer rate was 0.87 bits/min with an average throughput of 0.31 ± 0.12 character/min. These findings suggest that an online TCD-BCI can achieve reasonable accuracies with an intuitive language task, but with modest throughput. Future interface and signal classification enhancements are required to improve communication rate.

  3. Screening for fetal growth restriction with universal third trimester ultrasonography in nulliparous women in the Pregnancy Outcome Prediction (POP) study: a prospective cohort study.

    Science.gov (United States)

    Sovio, Ulla; White, Ian R; Dacey, Alison; Pasupathy, Dharmintra; Smith, Gordon C S

    2015-11-21

    Fetal growth restriction is a major determinant of adverse perinatal outcome. Screening procedures for fetal growth restriction need to identify small babies and then differentiate between those that are healthy and those that are pathologically small. We sought to determine the diagnostic effectiveness of universal ultrasonic fetal biometry in the third trimester as a screening test for small-for-gestational-age (SGA) infants, and whether the risk of morbidity associated with being small differed in the presence or absence of ultrasonic markers of fetal growth restriction. The Pregnancy Outcome Prediction (POP) study was a prospective cohort study of nulliparous women with a viable singleton pregnancy at the time of the dating ultrasound scan. Women participating had clinically indicated ultrasonography in the third trimester as per routine clinical care and these results were reported as usual (selective ultrasonography). Additionally, all participants had research ultrasonography, including fetal biometry at 28 and 36 weeks' gestational age. These results were not made available to participants or treating clinicians (universal ultrasonography). We regarded SGA as a birthweight of less than the 10th percentile for gestational age and screen positive for SGA an ultrasonographic estimated fetal weight of less than the 10th percentile for gestational age. Markers of fetal growth restriction included biometric ratios, utero-placental Doppler, and fetal growth velocity. We assessed outcomes for consenting participants who attended research scans and had a livebirth at the Rosie Hospital (Cambridge, UK) after the 28 weeks' research scan. Between Jan 14, 2008, and July 31, 2012, 4512 women provided written informed consent of whom 3977 (88%) were eligible for analysis. Sensitivity for detection of SGA infants was 20% (95% CI 15-24; 69 of 352 fetuses) for selective ultrasonography and 57% (51-62; 199 of 352 fetuses) for universal ultrasonography (relative sensitivity 2

  4. Atlas-based knee osteophyte assessment with ultrasonography and radiography

    DEFF Research Database (Denmark)

    Koski, J M; Kamel, Ayadi; Waris, P

    2016-01-01

    OBJECTIVES: To investigate intra- and inter-reader agreement of ultrasonography (US) and conventional radiography (CR) for the evaluation of osteophyte presence and size within the tibiofemoral joint. In addition, to correlate these findings with arthroscopic degeneration of the articular cartila...

  5. An unanticipated diagnosis with bedside ultrasonography in patients ...

    African Journals Online (AJOL)

    Although abdominal pain is a common presentation in emergency departments, rectus sheath hematoma (RSH) is among the rarest diagnosis. Here we present 2 cases of RSH likely caused by coughing due to upper respiratory tract infection. The two described cases were diagnosed by bedside ultrasonography and ...

  6. The accuracy rate of Alvarado score, ultrasonography, and ...

    African Journals Online (AJOL)

    Objective: In this study, we aim to compare the relationship between the Alvarado score, ultrasonography, and multislice computerized tomography (CT) findings used for the diagnosis of the patients who presented to our emergency unit with clinical features suggestive of acute appendicitis. Materials and Methods: ...

  7. Impact of magnetic resonance urography and ultrasonography on ...

    African Journals Online (AJOL)

    Background: (1) To evaluate the diagnostic value of magnetic resonance urography (MRU) in comparison with ultrasonography (US) to determine the extent of upper urinary tract dilation and (2) to evaluate the impact of MRU on therapy management. Materials and Methods: From January 2005 to December 2010, ...

  8. In-utero diagnosis of Norrie disease by ultrasonography.

    Science.gov (United States)

    Redmond, R M; Vaughan, J I; Jay, M; Jay, B

    1993-03-01

    Obstetric ultrasonography of an obligate Norrie disease carrier revealed bilateral retinal detachments in a third trimester male fetus. Postnatal examination confirmed the diagnosis of Norrie disease. DNA linkage analysis with the markers L1.28 and MAO had been uninformative for this family. This report suggests that retinal detachment occurs late in the gestation of the affected fetus.

  9. Primary muscular hydatid: preoperative diagnosis Throught computerized tomography and ultrasonography

    International Nuclear Information System (INIS)

    Macho Fernandez, J.M.; Marin Cardenas, M.A.; Mazas Artasona, L.; Lample Lacasa, C.; Otero Sierra, C.; Hernandez Navarrete, M.J.; Gomez-Pereda, R.

    1995-01-01

    Primary muscular hydatid disease, is extremely rare,- but not exceptional-, comparatively with other atypical localization. In this article the authors revised 474 patients with hydatid disease over a ten years period. Three cases of primary muscular localization were found. The ultrasonography and computed tomography facilitates the preoperative diagnosis. (Author) 40 refs

  10. Evaluation of the hip joint by computed tomography and ultrasonography

    International Nuclear Information System (INIS)

    Anda, S.

    1991-04-01

    In patients with dysplastic hips the acetabular angles and femoral anteversion were determined in a CT investigation. Comparative investigations of femoral anteversion were made by ultrasonography and biomedical radiography. The investigations are described and the general conclusions discussed. 205 refs., 15 figs., 10 tabs

  11. Preoperative radiological characterization of hepatic angiomyolipoma using magnetic resonance imaging and contrast-enhanced ultrasonography: a case report

    Directory of Open Access Journals (Sweden)

    Schmid Roland M

    2011-09-01

    Full Text Available Abstract Introduction A hepatic angiomyolipoma is a rare benign tumor of the liver composed of a mixture of smooth muscle cells, blood vessels and a variable amount of adipose tissue. Differentiating them from malignant liver tumors can often be very difficult. Case presentation We report the case of a 43-year-old Caucasian man presenting with a large liver mass in the right lobe. The results of magnetic resonance imaging and contrast-enhanced ultrasonography were consistent with a well-demarcated adipose tissue- containing tumor, showing prolonged hyperperfusion in comparison with the surrounding liver tissue. Surgery was performed and the diagnosis of hepatic angiomyolipoma was made with histopathology. Conclusion Preoperative radiological characterization using magnetic resonance imaging and contrast-enhanced ultrasonography may improve diagnostic accuracy of hepatic angiomyolipoma. Identification of smooth muscle cells, blood vessels and adipose tissue with a positive immunohistochemical reaction for HMB-45 is the final evidence for an angiomyolipoma.

  12. Prediction of adverse pregnancy outcomes using uterine artery Doppler imaging at 22-24 weeks of pregnancy: A North Indian experience

    Directory of Open Access Journals (Sweden)

    Deepti Verma

    2016-06-01

    Full Text Available Objective: The aim of this study was to assess the predictive value of uterine artery Doppler imaging at 22-24 weeks of gestation for adverse pregnancy outcomes. Materials and Methods: This was a prospective study in which uterine artery Doppler was performed at 22-24 weeks of gestation in 165 pregnant women with singleton pregnancies. A pulsatility index (PI more than 1.45 or bilateral uterine notching was labeled as abnormal Doppler. The pregnancy outcome was assessed in terms of normal outcome, preeclampsia, fetal growth restriction (FGR, low birth weight, spontaneous preterm delivery, oligohydramnios, fetal loss or at least one adverse outcome. Results: Out of 165 patients, 35 (21.2% had abnormal second trimester uterine artery Doppler. In pregnancies that resulted in preeclampsia (PE, (n=21, FGR, (n=21, and low birth weight (n=39, the median uterine artery PI was higher (1.52, 1.41, and 1.27 respectively. In the presence of abnormal Doppler, the risk of PE [OR=10.7, 95% confidence interval (CI: (3.91-29.1; p<0.001], FGR [OR=4.34, 95% CI: (1.62-11.6; p=0.002], low birth weight [OR=6.39, 95% CI: (3.16-12.9; p<0.001] and the risk of at least one obstetric complication [OR=8.73, 95% CI: (3.5-21.3; p<0.001] was significantly high. The positive predictive value of abnormal uterine artery Doppler was highest for preeclampsia (36.84% among all adverse pregnancy outcomes assessed. Conclusion: Uterine artery Doppler ultrasonography at 22-24 weeks of gestation is a significant predictor of at least one adverse pregnancy outcome, with the highest prediction for preeclampsia.

  13. [Carotid artery injury: value of Doppler screening in head injured patients].

    Science.gov (United States)

    Terminassian, A; Bonnet, F; Guerrini, P; Ricolfi, F; Delaunay, F; Beydon, L; Catoire, P

    1992-01-01

    A case is reported of a patient with a traumatic aneurysm of the intracranial part of the carotid artery occurring after a traffic accident. The patient was admitted in coma (Glasgow score 5), and presented with a depressed fracture of the frontal and parietal bones, a fracture of the left petrous pyramid and of the left anterior clinoid process, as well as of the right tympanic bone and temporomandibular joint. The borders of the left carotid canal seemed unaltered. Despite the lack of localised neurological signs, cervical and transcranial Doppler ultrasonography was carried out. Intracranial carotid blood flow was found to be altered on both sides. Angiography showed a false carotid aneurysm on the left side (carotid siphon portion C3), and a moderate irregular stenosis of the C2 part on the right. There were no brain lesions on the CT scan. Prophylactic treatment with heparin was started. The patient recovered normal consciousness within a fortnight. The false aneurysm increased in volume and was treated by embolisation. Flow speeds in the carotid siphons also returned to normal. The usefulness of routine screening of patients with petrous bone fractures with Doppler ultrasound is discussed.

  14. Evaluation of Portal Venous Velocity with Doppler Ultrasound in Patients with Nonalcoholic Fatty Liver Disease

    Energy Technology Data Exchange (ETDEWEB)

    Ulusan, Serife; Yakar, Tolga; Koc, Zafer [Baskent University Faculty of Medicine, Adana (Turkmenistan)

    2011-08-15

    We examined the relationship between portal venous velocity and hepatic-abdominal fat in patients with nonalcoholic fatty liver disease (NAFLD), using spectral Doppler ultrasonography (US) and magnetic resonance imaging (MRI). In this prospective study, 35 patients with NAFLD and 29 normal healthy adults (control group) underwent portal Doppler US. The severity of hepatic steatosis in patients with NAFLD was assessed by MRI through chemical shift imaging, using a modification of the Dixon method. Abdominal (intra-abdominal and subcutaneous) fat was measured by MRI. The difference in portal venous velocity between the patients with NAFLD and the control group was significant (p < 0.0001). There was no correlation between the degree of abdominal or hepatic fat and portal venous velocity (p > 0.05). There were strong correlations between the hepatic fat fraction and subcutaneous adiposity (p < 0.0001), intraperitoneal fat accumulation (p 0.017), and retroperitoneal fat accumulation (p < 0.0001). Our findings suggest that patients with NAFLD have lower portal venous velocities than normal healthy subjects.

  15. The Role of Doppler Ultrasound in Assessing the Therapeutic Response in Advanced Breast Cancer

    Directory of Open Access Journals (Sweden)

    Jamal Eyvazi-Ziaei

    2018-01-01

    Full Text Available Background and Objectives: Breast cancer is one of the most common cancers in Iran, which neo-adjuvant chemotherapy used to treat in advanced types to reduce tumor burden. The aim of this study was to evaluate the ultrasound scales of patients with advanced disease, using two common treatment methods include TACs (Taxotere, Adriamycin, and Cyclophosphamide and AC (Adriamycin, Cyclophosphamide. Material and Methods: Clinical examination and Doppler ultrasound were performed before and after treatment. Before and after the treatment, the size of the primary tumor and tumor vascularization, and the ultrasound Resistivity Index (RI, Pulsality Index (PI, Peak Systolic Velocity (PSV and the condition of the anterior lymph nodes, and the effect of two different therapies were investigated in response to treatment. The SPSS statistical software 17.0 was used to evaluate the relationship between the variables with 95% confidence interval, and P≤ 0.05. Results: The mean age of the patients was 48.90 (±10.58 SD years. From these, 8 were postmenopausal and 9 were menopausal, and in 3 cases the situation was unknown. There was significant difference between the PSV levels of the main breast mass, pre and post chemotherapy (P=0.004. Changes in other indexes of breast mass and axillary mass were not statistical significant. Conclusion: Color Doppler ultrasonography seems to be a promising alternative as an independent and complementary tool, to assess the response to treatment of breast masses to primary medical treatment in advanced breast cancers.

  16. Retrospective comparison of abdominal ultrasonography and radiography in the investigation of feline abdominal disease

    Science.gov (United States)

    Won, Wylen Wade; Sharma, Ajay; Wu, Wenbo

    2015-01-01

    Abdominal radiography and ultrasonography are commonly used as part of the initial diagnostic plan for cats with nonspecific signs of abdominal disease. This retrospective study compared the clinical usefulness of abdominal radiography and ultrasonography in 105 feline patients with signs of abdominal disease. The final diagnosis was determined more commonly with ultrasonography (59%) compared to radiography (25.7%). Ultrasonography was also able to provide additional clinically relevant information in 76% of cases, and changed or refined the diagnosis in 47% of cases. Based on these findings, ultrasonography may be sufficient as an initial diagnostic test for the investigation of feline abdominal disease. PMID:26483582

  17. Isolated Deep Venous Thrombosis: Implications for 2-Point Compression Ultrasonography of the Lower Extremity.

    Science.gov (United States)

    Adhikari, Srikar; Zeger, Wes; Thom, Christopher; Fields, J Matthew

    2015-09-01

    Two-point compression ultrasonography focuses on the evaluation of common femoral and popliteal veins for complete compressibility. The presence of isolated thrombi in proximal veins other than the common femoral and popliteal veins should prompt modification of 2-point compression technique. The objective of this study is to determine the prevalence and distribution of deep venous thrombi isolated to lower-extremity veins other than the common femoral and popliteal veins in emergency department (ED) patients with clinically suspected deep venous thrombosis. This was a retrospective study of all adult ED patients who received a lower-extremity venous duplex ultrasonographic examination for evaluation of deep venous thrombosis during a 6-year period. The ultrasonographic protocol included B-mode, color-flow, and spectral Doppler scanning of the common femoral, femoral, deep femoral, popliteal, and calf veins. Deep venous thrombosis was detected in 362 of 2,451 patients (14.7%; 95% confidence interval [CI] 13.3% to 16.1%). Thrombus confined to the common femoral vein alone was found in 5 of 362 cases (1.4%; 95% CI 0.2% to 2.6%). Isolated femoral vein thrombus was identified in 20 of 362 patients (5.5%; 95% CI 3.2% to 7.9%). Isolated deep femoral vein thrombus was found in 3 of 362 cases (0.8%; 95% CI -0.1% to 1.8%). Thrombus in the popliteal vein alone was identified in 53 of 362 cases (14.6%; 95% CI 11% to 18.2%). In our study, 6.3% of ED patients with suspected deep venous thrombosis had isolated thrombi in proximal veins other than common femoral and popliteal veins. Our study results support the addition of femoral and deep femoral vein evaluation to standard compression ultrasonography of the common femoral and popliteal vein, assuming that this does not have a deleterious effect on specificity. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  18. ROLE OF HIGH RESOLUTION ULTRASONOGRAPHY IN THE EVALUATION OF POSTERIOR SEGMENT LESIONS OF THE EYE

    Directory of Open Access Journals (Sweden)

    Rashmi Nagaraju

    2015-01-01

    Full Text Available BACKGRO UND: The superficial location of the eye, its cystic composition, and the advent of high - frequency ultrasound make sonography ideal for imaging the eye. Ultrasonography is a simple, readily available, non - invasive, non - ionizing, highly accurate, real time and cost effective modality . OBJECTIVES: 1 To evaluate the accuracy of high resolution B - mode ultrasonography in the diagnosis of posterior segment lesions of eye as compared to ophthalmoscopic examination particularly in cases of opaque conducting media . 2 To evaluate sonographic appearances of various posterior segment lesions of the eye . MATERIALS AND METHODS: 1 A prospective study was carried out on 62 cases with suspected posterior segment lesions of eye. All patients clinically suspected to have p osterior segment lesions in the presence of opaque conducting media were included in the study. Cases suspected to have isolated anterior segmental and extra ocular lesions were excluded. 2 HRUS was performed with Philips IU22 using high frequency probe ( 5 to 17 MHz utilizing contact method. 3 Sonological diagnosis was made based on sonographic features such as location, morphology, echo pattern, color Doppler characteristics, kinetics of the lesion with eye movements and acoustic characteristics of the lesion. 4 Subsequent clinical, lab investigations, surgical and histopathological examinations were carried out as applicable and final diagnosis was made which was correlated with the sonological diagnosis. Sonological diagnosis was also compared with op hthalmoscopic diagnosis. STATISTICAL ANALYSES: The validities and diagnostic accuracies of high resolution ultrasound and ophthalmoscopic examinations were calculated and compared. RESULTS AND CONCLUSIONS: 1 Ultrasound was the initial imaging modality opt ed in most of the cases as it was readily available, simple and cost effective modality. It establishes the diagnosis in significant number of cases superseding the accuracy

  19. Role of ultrasonography and magnetic resonance imaging in the diagnosis of intramuscular cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Tripathy, Sujit Kumar [Postgraduate Institute of Medical Education and Research, Department of Orthopedics, Chandigarh (India); Friarage Hospital, Department of Orthopedics, Northallerton (United Kingdom); Sen, Ramesh Kumar; Akkina, Narendranadh; Hampannavar, Aravind; Tahasildar, Naveen [Postgraduate Institute of Medical Education and Research, Department of Orthopedics, Chandigarh (India); Limaye, Rajiv [Friarage Hospital, Department of Orthopedics, Northallerton (United Kingdom)

    2012-09-15

    Nonspecific clinical presentations often lead to misdiagnosis of focal cysticercal myositis. This report emphasizes the role of ultrasonography and magnetic resonance imaging (MRI) in the diagnosis of solitary intramuscular cysticercosis. Six patients with persistent post-traumatic isolated muscular swelling were treated with analgesic and antibiotics, but the swelling did not subside. Radiographs showed soft tissue swelling with no bony abnormalities. Laboratory markers were inconclusive. Ultrasonographic and magnetic resonance images (MRI) showed typical features of intramuscular cysticercosis. Clinical, radiological, and fundoscopic evaluation of brain and eyes could not isolate any cysticercosis focus in these organs. Patients were treated with 3 weeks albendazole therapy. The identifying sonographic features of intramuscular cysticercosis, as evident from this case series, included an intramuscular elliptical or oval anechoic lesion with echogenic intralesional focus likely to be scolex. Magnetic resonance images showed orientation of the cyst along the direction of muscle fibers with T2W hyperintense signal and post-contrast perilesional enhancement. All patients responded to medical treatment. Cysticercosis may manifest as isolated muscular swelling without neurological or ocular involvement. Clinicians should be aware of this clinical condition to avoid misdiagnosis. Ultrasonography and magnetic resonance imaging are good diagnostic aids to establish soft tissue cysticercosis. (orig.)

  20. Role of ultrasonography and magnetic resonance imaging in the diagnosis of intramuscular cysticercosis

    International Nuclear Information System (INIS)

    Tripathy, Sujit Kumar; Sen, Ramesh Kumar; Akkina, Narendranadh; Hampannavar, Aravind; Tahasildar, Naveen; Limaye, Rajiv

    2012-01-01

    Nonspecific clinical presentations often lead to misdiagnosis of focal cysticercal myositis. This report emphasizes the role of ultrasonography and magnetic resonance imaging (MRI) in the diagnosis of solitary intramuscular cysticercosis. Six patients with persistent post-traumatic isolated muscular swelling were treated with analgesic and antibiotics, but the swelling did not subside. Radiographs showed soft tissue swelling with no bony abnormalities. Laboratory markers were inconclusive. Ultrasonographic and magnetic resonance images (MRI) showed typical features of intramuscular cysticercosis. Clinical, radiological, and fundoscopic evaluation of brain and eyes could not isolate any cysticercosis focus in these organs. Patients were treated with 3 weeks albendazole therapy. The identifying sonographic features of intramuscular cysticercosis, as evident from this case series, included an intramuscular elliptical or oval anechoic lesion with echogenic intralesional focus likely to be scolex. Magnetic resonance images showed orientation of the cyst along the direction of muscle fibers with T2W hyperintense signal and post-contrast perilesional enhancement. All patients responded to medical treatment. Cysticercosis may manifest as isolated muscular swelling without neurological or ocular involvement. Clinicians should be aware of this clinical condition to avoid misdiagnosis. Ultrasonography and magnetic resonance imaging are good diagnostic aids to establish soft tissue cysticercosis. (orig.)

  1. Doppler-guided retrograde catheterization system

    Science.gov (United States)

    Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.

    1991-05-01

    The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the

  2. Comparison of ultrasonography and radiography in diagnosis of rib fractures.

    Science.gov (United States)

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-08-01

    Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. In this cross-sectional study, consecutive patients with minor blunt chest trauma and suspected rib fractures presenting in Imam Reza Hospital located in Mashhad-Iran, between April 2013 and October 2013 were assessed by USG and radiography. The radiography was performed in a posteroanterior (PA) chest projection and oblique rib view centered over the area of trauma. The time duration spent in taking USG and radiography were recorded. The prevalence and location of fractures revealed by USG and radiography were compared. Sixty-one suspected patients were assessed. The male to female ratio was 2.4:1 (43 men and 18 women) with a mean ± SD age of (44.3 ± 19.7) years. There were totally 59 rib fractures in 38 (62.3%) patients based on radiography and USG, while 23 (37.7%) patients had no diagnostic evidence of rib lesions. USG revealed 58 rib fractures in 33 (54.1%) of 61 suspected patients and radiographs revealed 32 rib fractures in 20 (32.8%) of 61 patients. A total of 58 (98.3%) rib fractures were detected by USG, whereas oblique rib view and PA chest radiography showed 27 (45.8%) and 24 (40.7%) rib fractures, respectively. The average duration of USG was (12 ± 3) min (range 7-17 min), whereas the duration of radiography was (27 ± 6) min (range 15-37 min). The kappa coefficient showed a low level of agreement between both USG and PA chest radiography (kappa coefficient = 0.28), and between USG and oblique rib view (kappa coefficient = 0.32). USG discloses more fractures than radiography in

  3. MP3 compression of Doppler ultrasound signals.

    Science.gov (United States)

    Poepping, Tamie L; Gill, Jeremy; Fenster, Aaron; Holdsworth, David W

    2003-01-01

    The effect of lossy, MP3 compression on spectral parameters derived from Doppler ultrasound (US) signals was investigated. Compression was tested on signals acquired from two sources: 1. phase quadrature and 2. stereo audio directional output. A total of 11, 10-s acquisitions of Doppler US signal were collected from each source at three sites in a flow phantom. Doppler signals were digitized at 44.1 kHz and compressed using four grades of MP3 compression (in kilobits per second, kbps; compression ratios in brackets): 1400 kbps (uncompressed), 128 kbps (11:1), 64 kbps (22:1) and 32 kbps (44:1). Doppler spectra were characterized by peak velocity, mean velocity, spectral width, integrated power and ratio of spectral power between negative and positive velocities. The results suggest that MP3 compression on digital Doppler US signals is feasible at 128 kbps, with a resulting 11:1 compression ratio, without compromising clinically relevant information. Higher compression ratios led to significant differences for both signal sources when compared with the uncompressed signals. Copyright 2003 World Federation for Ultrasound in Medicine & Biology

  4. Editorial special issue on "Laser Doppler vibrometry"

    Science.gov (United States)

    Vanlanduit, Steve; Dirckx, Joris

    2017-12-01

    The invention of the laser in 1960 has opened up many opportunities in the field of measurement science and technology. Just a few years after the invention of the laser, a novel fluid flow measurement technique based on the Doppler effect was introduced: at that moment the laser Doppler anemometer or shortly LDA [1] was born. The technique enabled fluid velocity measurement by using the light of a He-Ne beam which was scattered by very small polystyrene spheres entrained in the fluid. Later on, in the late nineteen seventees it was recognized that the detection of the Doppler frequency shift that occurs when light is scattered by a moving surface can also be used to measure the vibration velocity of an object. The instrument to perform these vibration measurements was called the laser Doppler vibrometer or LDV [2]. In the last decades several technological advances were made in the field of laser Doppler vibrometry. The result is that nowadays, velocity measurements of fluids (using LDA) and vibrating objects (using LDV) are performed in many challenging applications in different fields (microelectronics, civil structures, biomedical engineering, material science, etc.).

  5. Development of the doppler electron velocimeter: theory.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.

    2007-03-01

    Measurement of dynamic events at the nano-scale is currently impossible. This paper presents the theoretical underpinnings of a method for making these measurements using electron microscopes. Building on the work of Moellenstedt and Lichte who demonstrated Doppler shifting of an electron beam with a moving electron mirror, further work is proposed to perfect and utilize this concept in dynamic measurements. Specifically, using the concept of ''fringe-counting'' with the current principles of transmission electron holography, an extension of these methods to dynamic measurements is proposed. A presentation of the theory of Doppler electron wave shifting is given, starting from the development of the de Broglie wave, up through the equations describing interference effects and Doppler shifting in electron waves. A mathematical demonstration that Doppler shifting is identical to the conceptually easier to understand idea of counting moving fringes is given by analogy to optical interferometry. Finally, potential developmental experiments and uses of a Doppler electron microscope are discussed.

  6. Ultrasonographic investigation of the Achilles tendon in elite badminton players using color Doppler.

    Science.gov (United States)

    Boesen, Morten Ilum; Boesen, Anders; Koenig, Merete Juhl; Bliddal, Henning; Torp-Pedersen, Soren

    2006-12-01

    The most frequent injuries in badminton players are in the lower extremities, especially in the Achilles tendon. The game of badminton may be related to abnormal intratendinous flow in the Achilles tendon as detected by color Doppler ultrasound. To a certain extent, this blood flow might be physiological, especially when examined after match. Cohort study (prevalence); Level of evidence, 3. Seventy-two elite badminton players were interviewed regarding Achilles tendon pain (achillodynia) in the preceding 3 years. Color Doppler was used to examine the tendons of 64 players before their matches and 46 players after their matches. Intratendinous color Doppler flow was graded from 0 to 4. The Achilles tendon was divided into dominant (eg, right side for right-handed players and vice versa) and nondominant side and classified as midtendon, preinsertional, and calcaneal areas. Of 72 players, 26 had experienced achillodynia in 34 tendons, 18 on the dominant side and 16 on the nondominant side. In 62% of the players with achillodynia, the problems had begun slowly, and the median duration of symptoms was 4 months (range, 0-36 months). Thirty-five percent had ongoing pain in their tendons for a median duration of 12 months (range, 0-12 months). Achillodynia was not associated with the self-reported training load or with sex, age, weight, singles or doubles players, or racket side. Forty-six players were scanned before and after match. At baseline, color Doppler flow was present in the majority of players, and only 7 (16%) players had no color Doppler flow in either tendon. After match, all players had some color Doppler flow in 1 or both tendons. Achillodynia and color Doppler flow were related in the nondominant Achilles tendon (chi-square, P = .008). The grades of Doppler flow also increased significantly after match in the preinsertional area in both the nondominant (P = .0002) and dominant (P = .005) side tendons. A large proportion of the players had experienced

  7. Doppler ultrasound study of portal hemodynamics in patients with Gaucher disease

    Directory of Open Access Journals (Sweden)

    Šarenac-Kovač Radmila

    2015-01-01

    Full Text Available Gaucher disease is a lysosomal storage disorder caused by a deficiency of the enzyme glucocerebrosidase and characterized by the presence of pathological macrophages laden with glucosylceramide. Hepatosplenomegaly is a common manifestation of Gaucher disease, but symptomatic portal hypertension is rarely seen. The study included 20 untreated adult patients with Gaucher disease (non-neuronopathic type 1 diagnosed with the presence of Gaucher cells in the bone marrow, and 20 healthy subjects as controls. The examination of patients included color Doppler ultrasonography (pulsed Doppler mode, resistive index (RI and Doppler perfusion index (DPI using a Toshiba Xario ultrasound machine and a convex array probe PVT-375AX (1.9-6 MHz with the objective of analyzing portal hemodynamics. Results showed that all patients had enlarged liver and spleen, and their average sizes were significantly larger than those in the healthy controls (liver: 17.04 vs.14.02 cm; spleen: 22.2 vs. 10.74 cm. DPI values were significantly different between patients and controls (0.15 vs. 0.21. Considering DPI <0.15 indicates arterial liver hypoperfusion and hypoxia, it can be concluded that a number of patients had a problem with liver oxygenation, which may be linked to the high angiotensin-converting enzyme (ACE levels obtained in the patients (339.42 U/L, 10 times greater than in control subjects. Since ACE is a potent vasoconstrictor produced by spleen macrophages in Gaucher disease, we can suppose that elevated ACE is associated with effects on the blood vessels of the liver and spleen. [Projekat Ministarstva nauke Republike Srbije, br. 175056

  8. Doppler visualization of ureteric jets in unilateral hydronephrosis in children and adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Cvitkovic Kuzmic, Andrea E-mail: andreack@workmail.com; Brkljacic, Boris; Rados, Marko; Galesic, Kresimir

    2001-09-01

    Objective: to evaluate Doppler visualization of ureteric jets in the assessment of unilateral kidney collecting system dilatation in children and adolescents. Methods and patients: color Doppler ultrasonography was performed in 27 patients with hydronephrosis (11 female, 16 male, age range 3-21 years, mean age 10.5{+-}4.4). Nine had acute obstruction due to ureteral calculus, seven had obstructive hydronephrosis due to uretero-pelvic junction (UPJ) stenosis, and 11 had non-obstructive hydronephrosis. Doppler was also performed in 32 healthy children (15 boys and 17 girls, age 2-17 years, mean age 7.8{+-}3.9), who represented the control group. Results: in the control group jets were visible in 57 out of 64 ureteric units (89%). The mean frequency of jets in healthy children was 4.1 jets per min. In all children with hydronephrosis, jets were visible in 25 out of 27 normal ureteric units (92.6%), and their mean frequency was 4.5 jets per min. In children with acute unilateral colic, ureteric jets were completely absent in eight of nine patients (89%). In children with obstructive hydronephrosis, due to UPJ stenosis, jets were absent in five out of seven patients (71.4%), and in children with non-obstructive hydronephrosis jets were absent in three out of eleven patients (27.3%). When jets are visible, their frequencies are much lower on the obstructed side as compared with normal side, while in cases of nonobstructive dilatation frequency of jets is similar on both sides. Conclusion: absence of jets in patients with acute obstruction due to ureteral calculus, strongly correlates with high-grade obstruction. In children with UPJ stenosis, presence of ureteric jet does not exclude significant obstruction, but the frequency of jets on the obstructed side is much lower as compared with the unaffected side. When there is absence of jet from the dilated side or significant asymmetry in jet frequency, hydronephrosis is likely to be obstructive.

  9. Contrast-enhanced color Doppler US in breast cancer: Tumoral vascularity correlated with angiogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun A; Yoon, Kwon Ha; Yun, Ki Jung; Lee, Kwang Man; Park, Ki Han; Juhng, Seon Kwan; Won, Jong Jin [Wonkwang University School of Medicine, Seoul (Korea, Republic of)

    2000-12-15

    To evaluate the effects of contrast-enhanced color Doppler ultrasonography (CDUS) on the depiction of vascularity and flow pattern in breast cancer and to determine the relationship between tumoral vascularity and angiogenesis. Twenty-one patients with breast cancer were prospectively evaluated with CDUS before and after injection of the contrast agent (SH U 508A, 2.5g, 300 mg/ml ). The tumoral vascularity was expressed as percentage of color Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The flow pattern (four-patterns; spotty, linear, branching, marginal) of the vascularity was analyzed. After surgery, tumor angiogenesis was assessed by microvessel density. The relationship between the vascularity on CDUS and microvessel density was statistically analyzed. At unenhanced CDUS, tumoral flow signals were detected in 12 lesions (48%); at contrast-enhanced CDUS, 18 lesions (86%). All These 18 lesions showed increased signals, compared with those at unenhanced CDUS. The percentage color Doppler area was 1.86 {+-} 0.48% at unenhanced CDUS and 5.23 {+-} 1.18% at contrast-enhanced CDUS. The flow patterns before contrast injection were spotty pattern in 11 tumors and linear pattern in one; after contrast injection, spotty in 8, linear in 4, branching in 5, and marginal in one. The tumoral vascularity at contrast-enhanced CDUS showed no significant correlation with microvessel density. Contrast-enhanced CDUS seems to be a valuable tool in the depiction of vascularity and characterization of flow pattern in breast cancer. However, tumoral vascularity on CDUS may not reflect tumoral angiogenesis.

  10. Tissue Doppler echocardiography – A case of right tool, wrong use

    Directory of Open Access Journals (Sweden)

    Thomas George

    2004-08-01

    Full Text Available Abstract Background The developments in echocardiography or ultrasound cardiography (UCG have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE is one such example? Presentation of the hypothesis TDE has been touted as advancement in the field of echocardiography. The striking play of colors, impressive waveforms and the seemingly accurate velocity values could be deceptive. TDE is a clear case of inappropriate use of technology. Testing the hypothesis To understand this, a comparison between flow Doppler and tissue Doppler is made. To make clinically meaningful velocity measurements with Doppler, we need prior knowledge of the line of motion. This is possible in blood flow but impossible in the complex myocardial motion. The qualitative comparison makes it evident that Doppler is best suited for flow studies. Implications of the hypothesis As of now TDE is going backwards using an indirect method when direct methods are better. The work on TDE at present is only debatable 'research and publication' material and do not translate into tangible clinical benefits. There are several advances like curved M-mode, strain rate imaging and tissue tracking in TDE. However these have been disappointing. This is due to the basic flaw in the application of the principles of Doppler. Doppler is best suited for flow studies and applying it to tissue motion is illogical. All data obtained by TDE is scientifically incorrect. This makes all the published papers on the subject flawed. Making diagnostic decisions based on this faulty application of technology would be unacceptable to the scientific cardiologist.

  11. Contribution of spiral artery blood flow changes assessed by transvaginal color Doppler sonography for predicting endometrial pathologies

    Directory of Open Access Journals (Sweden)

    Suna Kabil Kucur

    2013-01-01

    Full Text Available ive: To investigate the diagnostic value of blood flow measurements in spiral artery by transvaginal color Doppler sonography (CDS in predicting endometrial pathologies.Methods: Ninety-seven patients presenting with abnormal uterine bleeding and requiring endometrial assessment were included in this prospective observational study. Endometrial thickness, structure and echogenicity were recorded. Pulsatility index (PI and resistive index (RI of the spiral artery were measured by transvaginal CDS. Endometrial sampling was performed for all subjects. Sonographic and hystopathologic findings were compared.Results: The histopathological diagnoses were as follows; 39 cases (40.2% endometrial polyp, 9 cases (9.3% endometrial hyperplasia, 10 cases (10.3 submucous myoma, 7 cases (7.2% endometrium cancer, and 32 cases (33% nonspecific findings. The spiral artery PI in endometrium cancer group was highly significantly lower than other groups (p<0.01. The spiral artery RI was also significantly lower in the patients with malignant histology (p<0.05. Conclusion: Endometrial pathologies are associated significantly with endometrial spiral artery Doppler changes.Key words: Spiral artery, Doppler ultrasonography, endometrium

  12. Surface Charge Measurement of SonoVue, Definity and Optison: A Comparison of Laser Doppler Electrophoresis and Micro-Electrophoresis.

    Science.gov (United States)

    Ja'afar, Fairuzeta; Leow, Chee Hau; Garbin, Valeria; Sennoga, Charles A; Tang, Meng-Xing; Seddon, John M

    2015-11-01

    Microbubble (MB) contrast-enhanced ultrasonography is a promising tool for targeted molecular imaging. It is important to determine the MB surface charge accurately as it affects the MB interactions with cell membranes. In this article, we report the surface charge measurement of SonoVue, Definity and Optison. We compare the performance of the widely used laser Doppler electrophoresis with an in-house micro-electrophoresis system. By optically tracking MB electrophoretic velocity in a microchannel, we determined the zeta potentials of MB samples. Using micro-electrophoresis, we obtained zeta potential values for SonoVue, Definity and Optison of -28.3, -4.2 and -9.5 mV, with relative standard deviations of 5%, 48% and 8%, respectively. In comparison, laser Doppler electrophoresis gave -8.7, +0.7 and +15.8 mV with relative standard deviations of 330%, 29,000% and 130%, respectively. We found that the reliability of laser Doppler electrophoresis is compromised by MB buoyancy. Micro-electrophoresis determined zeta potential values with a 10-fold improvement in relative standard deviation. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Arm locking with Doppler estimation errors

    Energy Technology Data Exchange (ETDEWEB)

    Yu Yinan; Wand, Vinzenz; Mitryk, Shawn; Mueller, Guido, E-mail: yinan@phys.ufl.ed [Department of Physics, University of Florida, Gainesville, FL 32611 (United States)

    2010-05-01

    At the University of Florida we developed the University of Florida LISA Interferometer Simulator (UFLIS) in order to study LISA interferometry with hardware in the loop at a system level. One of the proposed laser frequency stabilization techniques in LISA is arm locking. Arm locking uses an adequately filtered linear combination of the LISA arm signals as a frequency reference. We will report about experiments in which we demonstrated arm locking using UFLIS. During these experiments we also discovered a problem associated with the Doppler shift of the return beam. The initial arm locking publications assumed that this Doppler shift can perfectly be subtracted inside the phasemeter or adds an insignificant offset to the sensor signal. However, the remaining Doppler knowledge error will cause a constant change in the laser frequency if unaccounted for. Several ways to circumvent this problem have been identified. We performed detailed simulations and started preliminary experiments to verify the performance of the proposed new controller designs.

  14. Inline Ultrasonic Rheometry by Pulsed Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Pfund, David M.; Greenwood, Margaret S.; Bamberger, Judith A.; Pappas, Richard A.

    2006-12-22

    This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined by using a pulsed ultrasonic Doppler velocimeter. This approach is ideal for making non-invasive, real-time measurements for monitoring and control. Rheograms of a shear thinning, thixotropic gel will be presented. The operating parameters and limitations of the Doppler-based instrument will be discussed. The most significant limitation is velocity gradient broadening of the Doppler spectra near the walls of the pipe. This limitation can be significant for strongly shear thinning fluids (depending also on the ratio of beam to pipe diameter and the transducer's insertion angle).

  15. Molecules cooled below the Doppler limit

    Science.gov (United States)

    Truppe, S.; Williams, H. J.; Hambach, M.; Caldwell, L.; Fitch, N. J.; Hinds, E. A.; Sauer, B. E.; Tarbutt, M. R.

    2017-12-01

    Magneto-optical trapping and sub-Doppler cooling have been essential to most experiments with quantum degenerate gases, optical lattices, atomic fountains and many other applications. A broad set of new applications await ultracold molecules, and the extension of laser cooling to molecules has begun. A magneto-optical trap (MOT) has been demonstrated for a single molecular species, SrF, but the sub-Doppler temperatures required for many applications have not yet been reached. Here we demonstrate a MOT of a second species, CaF, and we show how to cool these molecules to 50 μK, well below the Doppler limit, using a three-dimensional optical molasses. These ultracold molecules could be loaded into optical tweezers to trap arbitrary arrays for quantum simulation, launched into a molecular fountain for testing fundamental physics, and used to study collisions and chemistry between atoms and molecules at ultracold temperatures.

  16. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    Science.gov (United States)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  17. Point-of-care ultrasonography as a training milestone for internal medicine residents: the time is now.

    Science.gov (United States)

    Sabath, Bruce F; Singh, Gurkeerat

    2016-01-01

    Point-of-care (POC) ultrasonography is considered fundamental in emergency medicine training and recently has become a milestone in critical care fellowship programs as well. Currently, there is no such standard requirement for internal medicine residency programs in the United States. We present a new case and briefly review another case at our institution - a community hospital - in which internal medicine house staff trained in ultrasonography were able to uncover unexpected and critical diagnoses that significantly changed patient care and outcomes. We also review the growing evidence of the application of ultrasound in the diagnosis of a myriad of conditions encountered in general internal medicine as well as the mounting data on the ability of internal medicine residents to apply this technology accurately at the bedside. We advocate that the literature has sufficiently established the role of POC ultrasonography in general internal medicine that there should no longer be any delay in giving this an official place in the development of internal medicine trainees. This may be particularly useful in the community hospital setting where 24-h echocardiography or other sonography may not be readily available.

  18. Hamstring Elongation Quantified Using Ultrasonography During the Straight Leg Raise Test in Individuals With Low Back Pain.

    Science.gov (United States)

    Kellis, Eleftherios; Ellinoudis, Athanasios; Kofotolis, Nikolaos

    2015-06-01

    Although the straight leg raise (SLR) test frequently is used to assess hamstring extensibility in individuals with low back pain (LBP), evidence relating LBP, SLR, and hamstring extensibility remains unclear. The SLR measures the angle between the lifted leg and the horizontal, however, and, as such, it is not a direct measure of the elongation capacity of the hamstrings. To examine the differences in hamstring elongation (quantified via ultrasonography) and SLR score between individuals with LBP and asymptomatic controls and to determine the relationship between hamstring elongation, SLR, and functional disability scores. Cross-sectional study. University laboratory. Forty men and women with chronic LBP (mean ± SD, age 43.51 ± 3.71 years and 40 control subjects (age 45.11 ± 4.01 years) participated in this study. Passive SLR, elongation assessed via ultrasonography, and functional disability. SLR score, elongation of tendinous tissue within the semitendinosus muscle, and Oswestry Disability Index. Two-way analysis of variance tests indicated a significantly lower SLR score and a greater Oswestry score in LBP group compared with control subjects (P hamstring elongation (P > .05). Gender did not have an effect on all dependent measures (P > .05). Hamstring elongation showed a low correlation with SLR score and a minimal correlation with Oswestry score. These results indicate that the SLR score is not determined by hamstring elongation (quantified via ultrasonography). Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  19. Gallblader varices in children with portal cavernoma: duplex-Doppler and color Doppler ultrasound studies

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Lopez, A.

    1998-01-01

    To determine the prevalence of varices in the gallbladder wall, observed by duplex-Doppler and color Doppler ultrasound, in children with cavernoma of the portal vein. Nineteen patients with portal hypertension were studied prospectively by duplex-Doppler and color Doppler ultrasound: 12 of the patients had developed a cavernoma of the portal vein. The presence of peri vesicular varices was assessed in the group of patients with portal cavernoma. Duplex-Doppler and color Doppler ultrasound disclosed the presence of varices in gallbladder wall in nine of the 12 patients (75%). The varices appeared as anechoic and serpiginous areas, and Doppler ultrasound revealed slowed venous flow. However, the three patients in whom gallbldder varices were not detected presented collateral gastric ciculation and spontaneous splenorenal shunt. Gallbladder varices are common in children with portal vein cavernoma; they present hepatopetal flow. Their developments is not related to the size of the portal cavernoma, the presence of spontaneous portosystemic shunts, or endoscopic obliteration of gastric and esophageal varices. The detection of gallbladder varices in patients with portal hypertension who are to undergo biliary surgery is highly important for the surgeon, helping to avoid perioperative complications. (Author) 15 refs

  20. Three-dimensional power doppler ultrasound is useful to monitor the response to treatment in a patient with primary papillary serous carcinoma of the peritoneum.

    Science.gov (United States)

    Su, Jen-Min; Huang, Yu-Fang; Chen, Helen H W; Cheng, Ya-Min; Chou, Cheng-Yang

    2006-05-01

    To date, this is the first report to monitor changes of intratumor vascularization and the response to radiation and Cyberknife therapy in a patient with recurrent primary papillary serous carcinoma of the peritoneum by three dimensional (3D) power Doppler ultrasonography (PDUS). Transvaginal 3D PDUS detected a recurrent presacral tumor with abundant intratumor vascularity. Serial examinations of the tumor volume and serum CA-125 level were studied before, during, and 6 mo after therapy. Meanwhile, the intratumor blood flow was measured and expressed as vascularity indices. All of the tumor volume, intratumor vascularity indices and serum CA-125 level decreased progressively following therapy. A remaining lesion with nearly absent intratumor power Doppler signals suggested a scarring lesion posttreatment. Indeed, CT-guided tissue biopsy confirmed fibrotic change. 3D PDUS is useful to monitor the response to treatments and to differentiate residual tumors from lesions of scarring change posttreatment. It provides more accurate posttreatment information than pelvic computed tomography.

  1. Proposed protocols for peripheral and renal Doppler

    International Nuclear Information System (INIS)

    Fonseca Portuguez, Adriana

    2009-01-01

    A literature review was performed in order to prepare a summary of the important concepts of Doppler and applications in peripheral vascular evaluation and renal. The normal characteristics are summarized and explained in each vascular system and diagnostic criteria of the disorders frequently encountered in practice. Requested more studies have been identified and proposed protocols and report sheets have been developed to standardize the methodology of realization of several Doppler studies. The variability between operators has been treated to reduce as much as possible and follow-up studies have provided in patients who need. (author) [es

  2. Diagnostic sensitivity of radiography, ultrasonography, and magnetic resonance imaging for detecting shoulder osteochondrosis/osteochondritis dissecans in dogs.

    Science.gov (United States)

    Wall, Corey R; Cook, Cristi R; Cook, James L

    2015-01-01

    Radiography, magnetic resonance imaging (MRI), and ultrasonography are commonly used for diagnosis of shoulder osteochondrosis and osteochondritis dissecans (OC/OCD) in dogs, however there is a lack of published information on the relative diagnostic sensitivities of these modalities. The purpose of this prospective study was to compare diagnostic sensitivities of these modalities for detecting shoulder OC/OCD in a group of dogs, using arthroscopy as the reference standard. Inclusion criteria were history and clinical findings consistent with osteochondrosis and/or osteochondritis dissecans involving at least one shoulder. With informed client consent, both shoulders for all included dogs were examined using standardized radiography, ultrasonography, MRI, and arthroscopy protocols. One of three veterinary surgeons recorded clinical and arthroscopic findings without knowledge of diagnostic imaging findings. One of two veterinary radiologists recorded diagnostic imaging findings without knowledge of clinical and arthroscopic findings. Eighteen client-owned dogs (n = 36 shoulders) met inclusion criteria. Diagnostic sensitivity, specificity, and accuracy (correct classification rate) values for detecting presence or absence of shoulder osteochondrosis/osteochondritis dissecans were as follows: radiography (88.5%, 90%, 88.9%), ultrasonography (92%, 60%, 82.6%), and MRI (96%, 88.9%, 94.4%). Odds of a correct diagnosis for MRI were 3.2 times more than ultrasonography and two times more than radiography. For MRI detection of lesions, the sagittal T2 or PD-FAT SAT sequences were considered to be most helpful. For radiographic detection of lesions, the additional supinated-mediolateral and pronated-mediolateral projections were considered to be most helpful. Findings from the current study support more evidence-based diagnostic imaging recommendations for dogs with clinically suspected shoulder osteochondrosis or osteochondritis dissecans. © 2014 American College of

  3. Ultrasonography and cholescintigraphy in the diagnostics of biliary tree

    International Nuclear Information System (INIS)

    Iskrenova, Zh.; Minchev, D.

    1997-01-01

    The purpose is to determine whether a reversed sequence of bile flow (i.e. small bowel followed by gallbladder) could serve as an indicator of chronic cholecystitis. 43 hepatobiliary scans were reviewed retrospectively with attention to the relative order of gallbladder and small bowel appearance during the first hour. Usually radioactive bile flows initially into the gallbladder followed by passage into the small bowel. The scintigraphic findings were correlated with results from gallbladder histopathology and gallbladder ultrasonography in 11 patients. The specificity of a reversed sequence for chronic cholecystitis was 82% using ultrasonography and 100% for histopathology. The visualization of gallbladder after the small bowel appears in patients referred for possible biliary tract disease predicts chronic cholecystitis (author)

  4. Role of ultrasonography in the ocular and the orbital diseases

    International Nuclear Information System (INIS)

    Kim, S. R.; Kim, K. S.; Lee, Y. C.; Park, S. S.

    1984-01-01

    With conventional methods including orbital arteriography, orbital venography, penumoobitography and positive contrast orbitography, imaging of eyeball and orbit is not only difficult, invasive or expensive but also nonspecific in result. Ultrasonography provides safe, specific and reliable way to obtain image of eyeball and orbit. Fifty six ultrasonograms of 50 patients which were referred under the impression of various ophthalmic diseases were analyzed. 1. Sixteen cases were normal. 2. Ocular diseases were 26 cases and extraocular orbital diseases were 8 cases. 3. Among the ocular diseases, 9 foreign body cases, 6 retinal detachment cases, 5 vitreous hemorrhage 4. Among the extraocular orbital diseases, 6 pseudotumor cases, 1 pseudolymphoma, 1 eyelid cyst case were diagnosed. 5. Ultrasonic findings were specific enough to differentiated from diseases and well corresponded with clinical and pathological diagnosis. 6. It can be concluded that ultrasonography is one of the most reliable imaging method in ocular and extraocular orbital diseases

  5. Potentialities of computed tomography and ultrasonography in colonic cancer

    International Nuclear Information System (INIS)

    Gorshkov, A.N.

    2001-01-01

    Data of examination of 59 patients with colonic cancer were used to consider the potentialities of transabdominal, transrectal ultrasonography and X-ay compound tomography and to assess their value in diagnosing colonic cancer, including its minor forms. Ultrasound and computed tomographic semiotics of colonic cancer and determines a place of the above techniques in the algorithm of radiation and instrumental studies are described. Inclusion of these techniques into the diagnostic algorithm may solve a range of differentially diagnostic problems and allows a preliminary analysis to be made in a tumor lesion according to the International TNM classification. Ultrasonography and X-ray computed tomography should be included into a range of basic methods for diagnosis of colonic cancer [ru

  6. Ultrasonography of Midline Scalp Masses : A Preliminary Report

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyo Kyeong; Lee, Ho Kyu; Choi, Choong Gon; Kim, Kyeong Sook; Jung, Seung Mun; Suh, Dae Chul [Asan Medical Center University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    1995-06-15

    We report our ultrasonographic experiences in the evaluation of small midline scalp masses. Ultrasonography was performed in four patients with midline scalp mass less than 3cm and its connecting tract into the cranialcavity. Ultrasonographic findings were correlated with pathologic results. There were three cephaloceles and one cystic lymph angioma. Two encephalomenin-goceles, located in occipital region, were mixed cystic and solid lesions and one atretic meningocele in parietal region was a solid lesion. Ultrasonogram of all three cases showed calvarial defect and connecting tract into the cranial cavity. On the contrary, a cystic lymph angioma in occipital region was a purely cystic mass without an associated calvarial defect. We suppose that ultrasonography could be a useful screening tool in the evaluation of midline scalp masses

  7. Transrectal ultrasonography of anorectal disease: advantages and disadvantages

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Ju [Dept. of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2015-01-15

    Transrectal ultrasonography (TRUS) has been widely accepted as a popular imaging modality for Epub ahead of print evaluating the lower rectum, anal sphincters, and pelvic floor in patients with various anorectal diseases. It provides excellent visualization of the layers of the rectal wall and of the anatomy of the anal canal. TRUS is an accurate tool for the staging of primary rectal cancer, especially for early stages. Although magnetic resonance imaging is a modality complementary to TRUS with advantages for evaluating the mesorectum, external sphincter, and deep pelvic inflammation, three-dimensional ultrasonography improves the detection and characterization of perianal fistulas and therefore plays a crucial role in optimal treatment planning. The operator should be familiar with the anatomy of the rectum and pelvic structures relevant to the preoperative evaluation of rectal cancer and other anal canal diseases, and should have technical proficiency in the use of TRUS combined with an awareness of its limitations compared to magnetic resonance imaging.

  8. Diagnostic ultrasonography in cattle with abdominal fat necrosis.

    Science.gov (United States)

    Tharwat, Mohamed; Buczinski, Sébastien

    2012-01-01

    This study describes the ultrasonographic findings in 14 cows with abdominal fat necrosis. Ultrasonography of the abdomen revealed the presence of heterogeneous hyperechoic masses and hyperechoic omentum with localized masses floating in a hypoechoic peritoneal fluid. A hyperechogenic rim was imaged around both kidneys. The intestines were coated with hyperechoic capsules and the intestinal lumens were constricted. Ultrasonographic examination of the pancreatic parenchyma showed an overall increased echogenicity which was homogenously distributed in 3 cases. A diagnosis of abdominal fat necrosis was made with ultrasound-guided biopsy of the echogenic masses, and thereafter at postmortem examination. Results from this study demonstrate the efficacy of ultrasonography as an imaging modality for antemortem diagnosis of abdominal lipomatosis in cattle. To the authors' knowledge, this study is the first that illustrates ultrasonographic findings in cattle affected with abdominal lipomatosis.

  9. Interobserver Variation of the Renal Length Measurement on Ultrasonography

    International Nuclear Information System (INIS)

    Jeong, Yoong Ki; Chung, Hye Weon; Kim, Tae Sung; Ryoo, Jae Wook; Kim, Tae Kyoung; Kim, Seung Hyup

    1995-01-01

    We assessed interobserver variation in the measurement of the renal length on ultrasonography. Ultrasonographic examinations were performed in randomly selected 50 patients. The maximallenhths of both kidneys were measured with calipers during the scanning from frozen images by three observers in a blinded fashion. There was a relatively constant tendency of an observer to measure a renal length either longer or shorter than the other observer(Kendall coefficient>0.05). Average interobserver variations were 0.51 cm (±0.42 cm) in right kidney and 0.53 cm (±0.41 cm) in left kidney and were within 1 cm in 91% right and 89% of left kidney. Interobserver variation about 1cm should be considered in the measurement of the renal length on ultrasonography

  10. On use of ultrasonography in obstetrics and gynecology

    International Nuclear Information System (INIS)

    Woo, Kwang Suk; Lee, Yong Woo

    1984-01-01

    Ultrasonography is playing an very important in diagnosis of normal pregnancy and the other diseases in the fields of obstetrics and gynecology. It is mainly used B-mode and Real time linear scan for pregnancy such as fetal movement during its early stage, fetal position, placenta location and biparietal diameter during its middle stage, and amniotic fluid and placenta previa during its late stage, as well as tumor accompanying pregnancy. Ultrasonography has been extensively used in the fields of obstetrics and gynecology for obtaining detailed images of soft tissues without hazard to the fetus and pregnant woman. In view of the need for its professionalism of high degree of skill, this treatise will introduce clinical instances and images obtained in the sonography room of the Seoul National University Hospital

  11. Reliable and Valid Assessment of Point-of-care Ultrasonography

    DEFF Research Database (Denmark)

    Todsen, Tobias; Tolsgaard, Martin Grønnebæk; Olsen, Beth Härstedt

    2015-01-01

    physicians' OSAUS scores with diagnostic accuracy. RESULTS: The generalizability coefficient was high (0.81) and a D-study demonstrated that 1 assessor and 5 cases would result in similar reliability. The construct validity of the OSAUS scale was supported by a significant difference in the mean scores......OBJECTIVE: To explore the reliability and validity of the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale for point-of-care ultrasonography (POC US) performance. BACKGROUND: POC US is increasingly used by clinicians and is an essential part of the management of acute surgical...... conditions. However, the quality of performance is highly operator-dependent. Therefore, reliable and valid assessment of trainees' ultrasonography competence is needed to ensure patient safety. METHODS: Twenty-four physicians, representing novices, intermediates, and experts in POC US, scanned 4 different...

  12. Contrast-enhanced power Doppler US in the characterization of renal masses; Power Doppler con mezzo di contrasto nella caratterizzazione delle masse renali

    Energy Technology Data Exchange (ETDEWEB)

    Ascenti, G.; Zimbaro, G.; Mazziotti, S.; Visalli, C.; Racchiusa, S.; Vinci, S.; Scribano, E. [Messina Univ., Messina (Italy). Ist. di Scienze Radiologiche

    2000-09-01

    Purpose of this work is to report the results of a prospective study investigating the potentials of contrast-enhanced power Doppler in the diagnosis of expansive renal lesions. From 1997 to October 30, 1999, it was studied the case of 59 expansive renal lesions (28 malignant, 31 benign) in 48 patients (mean age 55 years, range 10-79) with power Doppler US before and after the administration of an echo-enhancing agent (Levovist, Schering AG, Berlin Germany). Were found 5 patterns of vascular architecture of the lesions, both before and after contrast agent administration, following the classification by Jinzaki e Coll. Power Doppler US showed vascular structures in 34 patients. The administration of Levovist revealed vessels in 12/25 lesions which had none at baseline studies and in 6 cases vascularity was particularly evident. Color signals were enhanced in all the 34 vascularized lesions, which allowed better definition of vascular patterns. The characterization of vascular patterns with baseline power Doppler US helped improve diagnostic accuracy compared to gray-scale US (58% versus 32%) for hyperechoic lesions, complex cysts and pseudomasses. Independent of contrast agent administration, the integration of gray-scale and power Doppler modes increased diagnostic accuracy even further (76% correct diagnoses). In our series, the US contrast agent did not increase the diagnostic accuracy of power Doppler in the differential diagnosis of hyperechoic renal lesions; conversely, Levovist can be advantageous for the characterization of suspected pseudomasses and complex cysts. [Italian] Scopo di questo articolo e' quello di riportare i risultati di uno studio prospettico finalizzato ad individuare le potenzialita' del power Doppler con mdc ecografico nella caratterizzazione delle lesioni espansive del rene. Dal 1997 al 30 ottobre 1999 sono state studiate 59 lesioni renali (28 maligne, 31 benigne) in 48 pazienti (eta' media 55 anni, intervallo 10

  13. Comparison of ultrasonography and radiography in diagnosis of rib fractures

    OpenAIRE

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-01-01

    Purpose: Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. Methods: In this cross-s...

  14. Pictorial essay: B-scan ultrasonography in ocular abnormalities

    International Nuclear Information System (INIS)

    Aironi, VD; Gandage, SG

    2009-01-01

    B-scan ultrasonography (USG) is a simple, noninvasive tool for diagnosing lesions of the posterior segment of the eyeball. Common conditions such as cataract, vitreous degeneration, retinal detachment, ocular trauma, choroidal melanoma, and retinoblastoma can be accurately evaluated with this modality. B-scan USG is cost-effective, which is an important consideration in the rural setting. In addition, it is noninvasive and easily available and the results are reproducible

  15. Ultrasonography of the omasum in 30 Saanen goats

    Directory of Open Access Journals (Sweden)

    Jacquat Désirée

    2011-02-01

    Full Text Available Abstract Background Primary diseases of the omasum are uncommon in goats, although the omasum may be involved in various gastrointestinal disorders. Examination of the caprine omasum via ultrasonography requires a good understanding of the normal appearance of the organ. However, in contrast to cattle, there is a lack of reference information on this topic in goats. Thus, the goal of the present study was to describe the results of ultrasonography of the omasum in 30 healthy Saanen goats. Results Ultrasonography was carried out in standing, non-sedated goats using a 5.0 MHz linear transducer. The location and size of the omasum, thickness of the omasal wall and visualisation of the abomasal laminae, contents and contractions were assessed. The omasum was visible from the 9th intercostal space (ICS in all the goats, and from the 8th and 10th ICSs in 29 and 24 goats, respectively. The omasum was seen medial to the liver, but only the omasal wall closest to the transducer was visible. The dorsal omasal limit formed a dorsally convex curve running from cranioventral to caudodorsal and was furthest from the dorsal midline in the 6th ICS. The ventral omasal limit formed a ventrally convex curve. The size of the omasum was largest (10.2 ± 3.1 cm in the 9th ICS and decreased cranially and caudally from this position. Active omasal motility was recorded in 20 goats with 0.3 to 2.0 contractions per minute. Conclusions The findings of this study provide reference ranges for the interpretation of the location and size of the omasum in goats with suspected omasal abnormalities. Ultrasonography is an ideal diagnostic tool for evaluation of the omasum, which is not accessible to conventional examination techniques, such as inspection, palpation, percussion and auscultation.

  16. Urinary tract infection in children: Role of ultrasonography

    International Nuclear Information System (INIS)

    Lee, Hye Won; Lee, Sun Wha; Ko, Young Tae; Lim, Joo Won

    1994-01-01

    To evaluate diagnostic usefulness of ultrasonography(US) in pediatric patient with urinary tract infection. Fifty-five children with urinary tract infection underwent renal ultrasonography and voiding cystourethrography(VCUG). The imaging findings were analyzed retrospectively. Renal sonograms were normal in 34 of 55 children(62%). Five of 34 patients with normal sonogram had vesicoureteral reflux of grade I and III on VCUG. Renal sonograms were abnormal in 21 of 55 children(38%). Sonographic findings included hydronephrosis, hyperechoic kidney, nephromegaly, altrophic kidney, renal abscess, and duplex ureter. Eleven of 21 patient with abnormal sonogram had vesicoureteral reflux of grade I to IV on VCUG. Ultrasonography is an useful and reliable initial screening examination in the investigation of children with UTI. Unfortunately US is neither sufficiently sensitive nor specific for detecting VUR. VCUG provides confirmative and valuable information about vesicoureteral reflux, and VCUG should be considered as a next modality for UTI. The combined use of sonography and VCUG provides more valuable information in urinary tract infection

  17. Ultrasonography of the equine shoulder: technique and normal appearance.

    Science.gov (United States)

    Tnibar, M A; Auer, J A; Bakkali, S

    1999-01-01

    This study was intended to document normal ultrasonographic appearance of the equine shoulder and anatomic landmarks useful in clinical imaging. Both forelimbs of five equine cadavers and both forelimbs of six live adult horses were used. To facilitate understanding of the images, a zoning system assigned to the biceps brachii and to the infraspinatus tendon was developed. Ultrasonography was performed with a real-time B-mode semiportable sector scanner using 7.5- and 5-MHz transducers. On one cadaver limb, magnetic resonance imaging (MRI) was performed using a system at 1.5 Tesla, T1-weighted spin-echo sequence. Ultrasonography images were compared to frozen specimens and MRI images to correlate the ultrasonographic findings to the gross anatomy of the shoulder. Ultrasonography allowed easy evaluation of the biceps brachii and the infraspinatus tendon and their bursae, the supraspinatus muscle and tendons, the superficial muscles of the shoulder, and the underlying humerus and scapula. Only the lateral and, partially, the caudal aspects of the humeral head could be visualized with ultrasound. Ultrasonographic appearance, orientation, and anatomic relationships of these structures are described. Ultrasonographic findings correlated well with MRI images and with gross anatomy in the cadavers' limbs.

  18. Peritoneal inclusion cysts: Changes on follow-up ultrasonography

    International Nuclear Information System (INIS)

    Kim, Jung Sik; Lee, Jin Hee; Lee, Hee Jung; Lee, Sung Moon; Woo, Seong Ku

    2003-01-01

    To evaluate the volume change of peritoneal inclusion cysts on the follow-up ultrasonography (US). From March 1995 to May 1999, thirty seven women with ultrasonographically diagnosed peritoneal inclusion cysts were included in this study. Six patients underwent surgery for several reasons. Follow-up ultrasonography was performed 70-456 days (mean=191 days) after initial US examination in 12 of the remaining 31 patient with no further treatment. US was performed with a 3.5 or 4 MHz transabdominal probe in all 18 patients who underwent either surgery or follow-up US, and additional tranvaginal US examination using a 5-7 MHz probe in 15 of 18 patients. The volume change of the cysts was recorded for each US examination. Three cysts (25%) (volume=170 cm 3 , 61 cm 3 , and 38 cm 3 , respectively) were completely resolved on the follow-up US while the other nine cysts showed a decreased volume in seven patients (58%) and increased volume in two patients (17%). Spontaneous regression of peritoneal inclusion cysts is more common than it is believed to be, and ultrasonography may be a useful follow-up examination for peritoneal inclusion cysts.

  19. Ultrasonography in the evaluation of tongue and mouth pathology

    International Nuclear Information System (INIS)

    Lee, Chan Wha; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Lee, Jong Tae; Hong, Won Pyo; Park, Hyung Sik

    1991-01-01

    The evaluation of the tongue and mouth floor using the CT scan can be limited due to dental artifacts. Because the therapeutic plan depends on the nature and the cancer staging of lesions, it is essential to obtain accurate evaluation of lesions. In this study are explored the of Ultrasonography for the evaluation of tongue and mouth floor pathology. We have obtained ultrasonograms in 20 patients who had benign and malignant lesions in the tongue and mouth floor. Comparative analysis was made on 15 patients who underwent both CT and ultrasonography. We used the bimanual compression technique and the phonation technique during real-time scanning. Out of 15 cases, six had tongue cancer, and seven of them had cancer of the mouth floor. The other cases included a ranula, a dermoid cyst, a Ludwig's angina, and abscess of salivary gland, and one care with stones of the submandibular gland. All the benign and malignant masses appeared hypoechoic. Even though the lesions of tongue and mouth floor could not be evaluated by CT scan due to dental artifacts and extremely small size in 5 cases, ultrasonogram using the bimanual compression technique demonstrated good localization of the lesion, and also was greatly helpful in visualizing the invasion of the surrounding structures. Ultrasonography of the tongue and mouth floor proved to be superior to the CT scan not only in delineating the size and extent of the primary lesion, but also in visualizing invasion of surrounding structures

  20. Near-infrared Fluorescence Optical Imaging in Early Rheumatoid Arthritis: A Comparison to Magnetic Resonance Imaging and Ultrasonography.

    Science.gov (United States)

    Krohn, Michaela; Ohrndorf, Sarah; Werner, Stephanie G; Schicke, Bernd; Burmester, Gerd-Rüdiger; Hamm, Bernd; Backhaus, Marina; Hermann, Kay-Geert A

    2015-07-01

    Near-infrared fluorescence optical imaging (FOI) is a novel imaging technology in the detection and evaluation of different arthritides. FOI was validated in comparison to magnetic resonance imaging (MRI), greyscale ultrasonography (GSUS), and power Doppler ultrasonography (PDUS) in patients with early rheumatoid arthritis (RA). Hands of 31 patients with early RA were examined by FOI, MRI, and US. In each modality, synovitis of the wrist, metacarpophalangeal joints (MCP) 2-5, and proximal interphalangeal joints (PIP) 2-5 were scored on a 4-point scale (0-3). Sensitivity and specificity of FOI were analyzed in comparison to MRI and US as reference methods, differentiating between 3 phases of FOI enhancement (P1-3). Intraclass correlation coefficients (ICC) were calculated to evaluate the agreement of FOI with MRI and US. A total of 279 joints (31 wrists, 124 MCP and 124 PIP joints) were evaluated. With MRI as the reference method, overall sensitivity/specificity of FOI was 0.81/0.00, 0.49/0.84, and 0.86/0.38 for wrist, MCP, and PIP joints, respectively. Under application of PDUS as reference, sensitivity was even higher, while specificity turned out to be low, except for MCP joints (0.88/0.15, 0.81/0.76, and 1.00/0.27, respectively). P2 appears to be the most sensitive FOI phase, while P1 showed the highest specificity. The best agreement of FOI was shown for PDUS, especially with regard to MCP and PIP joints (ICC of 0.57 and 0.53, respectively), while correlation with MRI was slightly lower. FOI remains an interesting diagnostic tool for patients with early RA, although this study revealed limitations concerning the detection of synovitis. Further research is needed to evaluate its full diagnostic potential in rheumatic diseases.

  1. Is salivary gland ultrasonography a useful tool in Sjögren's syndrome? A systematic review.

    Science.gov (United States)

    Jousse-Joulin, Sandrine; Milic, Vera; Jonsson, Malin V; Plagou, Athena; Theander, Elke; Luciano, Nicoletta; Rachele, Pascale; Baldini, Chiara; Bootsma, Hendrika; Vissink, Arjan; Hocevar, Alojzija; De Vita, Salvatore; Tzioufas, Athanasios G; Alavi, Zarin; Bowman, Simon J; Devauchelle-Pensec, Valerie

    2016-05-01

    Ultrasonography (US) is a sensitive tool in the diagnosis of major salivary gland abnormalities in primary Sjögren's syndrome (pSS). The aim of this systematic review was to assess the metric properties of this technique. PUBMED and EMBASE databases were searched. All publications between January 1988 and January 2013 were considered. Data were extracted from the articles meeting the inclusion criteria according to US definition of salivary gland scoring system and metric properties studied. The type and number of glands tested, study design and metric properties according to OMERACT filter (truth, discrimination, feasibility) were assessed. Of 167 publications identified initially with PUBMED and EMBASE, 31 met the inclusion criteria. The number of pSS patients varied among the studies from 16 to 140. The diagnosis of pSS was in line in most of the cases with the American-European Consensus Group (AECG) classification criteria for Sjögren's syndrome. The US examination was performed in suspected pSS only in studies in which the sensitivity ranged from 45.8 to 91.6% and specificity from 73 to 98.1%. There was heterogeneity in regard to the definition of US in B-mode and few studies used US in colour Doppler. Few studies reported reliability of US and sensitivity to change in pSS. US is a valuable tool for detecting salivary gland abnormalities in pSS. Its reliability has been poorly investigated and there is considerable variation in the definition of US abnormalities. Further studies are required to validate and standardize the US definition of salivary gland in pSS. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Diagnostic value of contrast-enhanced ultrasonography in the characterization of ovarian tumors().

    Science.gov (United States)

    Sconfienza, L M; Perrone, N; Delnevo, A; Lacelli, F; Murolo, C; Gandolfo, N; Serafini, G

    2010-03-01

    Vascularity influences the characteristics of gynecologic tumors observed with direct imaging techniques that reveal the macrovascular component of these lesions (color and power Doppler) and with indirect imaging involving the administration of contrast agents to examine the microcirculation and interstitial perfusion (contrast-enhanced computed tomography [CT] and magnetic resonance [MR] imaging). The purpose of this study was to determine whether contrast-enhanced ultrasonography (CEUS) of ovarian lesions provides useful information that cannot be obtained with conventional US. We used CEUS to assess 72 nonspecific adnexal lesions in 61 patients. CEUS was performed with a 4.8-ml bolus of a second-generation ultrasonographic contrast agent and dedicated imaging algorithms. For each lesion, B-mode morphology, CEUS morphology, and time/intensity curves were evaluated. In 8/61 cases (13.1%) CEUS offered no additional morphovascular information. In 38/61 cases (62.3%), it provided additional information that did not modify the management of the lesion, and in 15/61 cases (24.6%) it gave additional information that modified the management of the lesion. Malignant lesions were characterized by significantly shorter times to peak enhancement (11.9 ± 3.1 s vs 19.8 ± 4.0 s p < 0.01) and significantly higher peak intensity (24.7 ± 4.2 dB vs 17.8 ± 3.3 dB p < 0.01) compared with benign lesions. CEUS improves diagnostic confidence in the characterization of liquid-corpuscular lesions where conventional US is inconclusive. CEUS can be proposed as a valid alternative to CT and MR. However, information obtained by CEUS influences the therapy in a limited percentage of cases (24.6%).

  3. Evaluation of Thyroid Disorders During Head-and-Neck Radiotherapy by Using Functional Analysis and Ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Bakhshandeh, Mohsen [Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Hashemi, Bijan, E-mail: bhashemi@modares.ac.ir [Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Mahdavi, Seyed Rabie [Department of Medical Physics, Faculty of Medical Sciences, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Nikoofar, Alireza [Department of Radiation Oncology, Hafte-Tir Hospital, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Edraki, Hamid Reza [Department of Radiology, Panzdahe-Khordad Hospital, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Kazemnejad, Anoshirvan [Department of Biostatistics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran (Iran, Islamic Republic of)

    2012-05-01

    Purpose: To evaluate thyroid function and vascular changes during radiotherapy for patients with head and neck cancer. Methods and Materials: Fifty patients treated with primary or postoperative radiotherapy for various cancers in the head and neck region were prospectively evaluated. The serum samples (triiodothyronine [T3], thyroxine [T4], thyroid-stimulating hormone [TSH], free triiodothyronine [FT3], and free thyroxine [FT4]), the echo level of the thyroid gland, and color Doppler ultrasonography (CDU) parameters of the right inferior thyroid artery (RITA) of the patients were measured before and at regular intervals during radiotherapy. The thyroid gland dose-volume histograms of the patients were derived from their computed tomography-based treatment plans. Results: There was a significant fall in TSH level (p < 0.0001) but an increase in FT4 (p < 0.0001) and T4 (p < 0.022) levels during the radiotherapy course. The threshold dose required to produce significant changes was 12 Gy (Biologically Effective Dose in 2-Gy fractions, BED{sub 2}). There were significant rises in the patients' pulsatility index, resistive index, peak systolic velocity, blood volume flow levels, and RITA diameter (p < 0.0001), as detected by CDU during radiotherapy, compared to those parameters measured before the treatment. Hypoechogenicity and irregular echo patterns (p < 0.0001) were seen during radiotherapy compared to those before treatment. There was significant Pearson's correlation between the CDU parameters and T4, FT4, and TSH levels. Conclusions: Radiation-induced thyroiditis is regarded as primary damage to the thyroid gland. Thyroiditis can subsequently result in hypothyroidism or hyperthyroidism. Our results demonstrated that changes in thyroid vessels occur during radiotherapy delivered to patients. Vessel changes also can be attributed to the late effect of radiation on the thyroid gland. The hypoechogenicity and irregular echo patterns observed in patients

  4. Evaluation of Thyroid Disorders During Head-and-Neck Radiotherapy by Using Functional Analysis and Ultrasonography

    International Nuclear Information System (INIS)

    Bakhshandeh, Mohsen; Hashemi, Bijan; Mahdavi, Seyed Rabie; Nikoofar, Alireza; Edraki, Hamid Reza; Kazemnejad, Anoshirvan

    2012-01-01

    Purpose: To evaluate thyroid function and vascular changes during radiotherapy for patients with head and neck cancer. Methods and Materials: Fifty patients treated with primary or postoperative radiotherapy for various cancers in the head and neck region were prospectively evaluated. The serum samples (triiodothyronine [T3], thyroxine [T4], thyroid-stimulating hormone [TSH], free triiodothyronine [FT3], and free thyroxine [FT4]), the echo level of the thyroid gland, and color Doppler ultrasonography (CDU) parameters of the right inferior thyroid artery (RITA) of the patients were measured before and at regular intervals during radiotherapy. The thyroid gland dose-volume histograms of the patients were derived from their computed tomography-based treatment plans. Results: There was a significant fall in TSH level (p 2 ). There were significant rises in the patients’ pulsatility index, resistive index, peak systolic velocity, blood volume flow levels, and RITA diameter (p < 0.0001), as detected by CDU during radiotherapy, compared to those parameters measured before the treatment. Hypoechogenicity and irregular echo patterns (p < 0.0001) were seen during radiotherapy compared to those before treatment. There was significant Pearson’s correlation between the CDU parameters and T4, FT4, and TSH levels. Conclusions: Radiation-induced thyroiditis is regarded as primary damage to the thyroid gland. Thyroiditis can subsequently result in hypothyroidism or hyperthyroidism. Our results demonstrated that changes in thyroid vessels occur during radiotherapy delivered to patients. Vessel changes also can be attributed to the late effect of radiation on the thyroid gland. The hypoechogenicity and irregular echo patterns observed in patients may result from the increase in intrathyroidal flow.

  5. Distribution of Doppler Redshifts of Associated Absorbers of SDSS ...

    Indian Academy of Sciences (India)

    The authors searched all ... quasar, where the contribution of the Doppler motion is relatively small. ..... might contribute to the Doppler redshift distribution. 5. ... out accounting for the contamination of intervening absorption systems, which can.

  6. GRIP DOPPLER AEROSOL WIND LIDAR (DAWN) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Doppler Aerosol WiNd Lidar (DAWN) Dataset was collected by the Doppler Aerosol WiNd (DAWN), a pulsed lidar, which operated aboard a NASA DC-8 aircraft...

  7. Operational Bright-Band Snow Level Detection Using Doppler Radar

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A method to detect the bright-band snow level from radar reflectivity and Doppler vertical velocity data collection with an atmospheric profiling Doppler radar. The...

  8. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The EDOP provides vertically profiled reflectivity and Doppler velocity at aircraft nadir along the flight track. The ER-2 Doppler radar (EDOP) is an X-band (9.6...

  9. ISAR imaging using the instantaneous range instantaneous Doppler method

    CSIR Research Space (South Africa)

    Wazna, TM

    2015-10-01

    Full Text Available In Inverse Synthetic Aperture Radar (ISAR) imaging, the Range Instantaneous Doppler (RID) method is used to compensate for the nonuniform rotational motion of the target that degrades the Doppler resolution of the ISAR image. The Instantaneous Range...

  10. Transcranial Doppler velocimetry in aneurysmal subarachnoid haemorrhage

    DEFF Research Database (Denmark)

    Staalsø, J M; Edsen, T; Romner, B

    2013-01-01

    -coded transcranial Doppler (TCCD), with the secondary aim of describing prediction of angiographic vasospasm and mortality. METHODS: /st>Sixty patients and 70 healthy controls were each examined in duplicate by alternating operators. A total of 939 measurements divided on 201 examination sets were conducted by four...

  11. Doppler Sonographic Evaluation of Venogenic Extremity Swellings ...

    African Journals Online (AJOL)

    2017-09-14

    Sep 14, 2017 ... potentially lead to many complications including life-threatening pulmonary arterial thrombosis. Screening and confirmation ... and exclusion of acute lower extremity DVT. Duplex ultrasound is considered as the ... this study evaluates the role of Doppler sonography in the clinical management of suspected.

  12. Complex regression Doppler optical coherence tomography

    Science.gov (United States)

    Elahi, Sahar; Gu, Shi; Thrane, Lars; Rollins, Andrew M.; Jenkins, Michael W.

    2018-04-01

    We introduce a new method to measure Doppler shifts more accurately and extend the dynamic range of Doppler optical coherence tomography (OCT). The two-point estimate of the conventional Doppler method is replaced with a regression that is applied to high-density B-scans in polar coordinates. We built a high-speed OCT system using a 1.68-MHz Fourier domain mode locked laser to acquire high-density B-scans (16,000 A-lines) at high enough frame rates (˜100 fps) to accurately capture the dynamics of the beating embryonic heart. Flow phantom experiments confirm that the complex regression lowers the minimum detectable velocity from 12.25 mm / s to 374 μm / s, whereas the maximum velocity of 400 mm / s is measured without phase wrapping. Complex regression Doppler OCT also demonstrates higher accuracy and precision compared with the conventional method, particularly when signal-to-noise ratio is low. The extended dynamic range allows monitoring of blood flow over several stages of development in embryos without adjusting the imaging parameters. In addition, applying complex averaging recovers hidden features in structural images.

  13. Doppler Shift Compensation Schemes in VANETs

    Directory of Open Access Journals (Sweden)

    F. Nyongesa

    2015-01-01

    Full Text Available Over the last decade vehicle-to-vehicle (V2V communication has received a lot of attention as it is a crucial issue in intravehicle communication as well as in Intelligent Transportation System (ITS. In ITS the focus is placed on integration of communication between mobile and fixed infrastructure to execute road safety as well as nonsafety information dissemination. The safety application such as emergence alerts lays emphasis on low-latency packet delivery rate (PDR, whereas multimedia and infotainment call for high data rates at low bit error rate (BER. The nonsafety information includes multimedia streaming for traffic information and infotainment applications such as playing audio content, utilizing navigation for driving, and accessing Internet. A lot of vehicular ad hoc network (VANET research has focused on specific areas including channel multiplexing, antenna diversity, and Doppler shift compensation schemes in an attempt to optimize BER performance. Despite this effort few surveys have been conducted to highlight the state-of-the-art collection on Doppler shift compensation schemes. Driven by this cause we survey some of the recent research activities in Doppler shift compensation schemes and highlight challenges and solutions as a stock-taking exercise. Moreover, we present open issues to be further investigated in order to address the challenges of Doppler shift in VANETs.

  14. Fifty Years of HF Doppler Observations

    Directory of Open Access Journals (Sweden)

    T Ogawa

    2009-04-01

    Full Text Available High frequency Doppler observations of the ionosphere began in August of 1957 in Kyoto. The number of the observation points worldwide were about 40 in 1980 and are about 20 at present. By this method the movement of the ionosphere reflection height and electron density below the height can be observed. Such variations are occurred by a wide variety of sources.

  15. Ultrasonic Doppler color in glaucoma: Concordance study

    International Nuclear Information System (INIS)

    Uriza, Felipe; Useche, Nicolas

    2005-01-01

    Our study demonstrates that US color Doppler is a non invasive, reliable and reproducible method for the evaluation of the orbitary flow in normal and glaucomatous patients. However is suggested that every group evaluates the inter and intraobserver variability because of the lack of universal reference velocity measurements

  16. Aerosol distribution measurements by laser - Doppler - spectroscopy

    International Nuclear Information System (INIS)

    Baldassari, J.

    1977-01-01

    Laser-Doppler-Spectroscopy is used to study particle size distribution, especially sodium aerosols, in the presence of uncondensable gases. Theoretical basis are given, and an experimental technique is described. First theoretical results show reasonably good agreement with experimental data available; this method seems to be a promising one. (author)

  17. Laser Doppler thermometry in flat flames

    NARCIS (Netherlands)

    Maaren, van A.; Goey, de L.P.H.

    1994-01-01

    Laser Doppler Velocimetry measurements are performed in flat flames, stabilized on a newly developed flat-flame burner. It is shown that the velocity component perpendicular to the main flow direction, induced by expansion in the reaction zone and buoyancy in the burnt gas, is significant. A method

  18. MRI versus ultrasonography to assess meniscal abnormalities in acute knees.

    Science.gov (United States)

    Cook, James L; Cook, Cristi R; Stannard, James P; Vaughn, Gavin; Wilson, Nichole; Roller, Brandon L; Stoker, Aaron M; Jayabalan, Prakash; Hdeib, Moses; Kuroki, Keiichi

    2014-08-01

    While magnetic resonance imaging (MRI) is often considered the "gold standard" diagnostic imaging modality for detection of meniscal abnormalities, it is associated with misdiagnosis in as high as 47% of cases, is costly, and is not readily available to a large number of patients. Ultrasonographic examination of the knee has been reported to be an effective diagnostic tool for this purpose with the potential to overcome many of the shortcomings of MRI. The purpose of this study is to determine the clinical usefulness of ultrasonography for diagnosis of meniscal pathology in patients with acute knee pain and compare its diagnostic accuracy to MRI in a clinical setting. With Institutional Review Board approval, patients (n = 71) with acute knee pain were prospectively enrolled with informed consent. Preoperative MRI (1.5 T) was performed on each affected knee using the hospital's standard equipment and protocols and read by faculty radiologists trained in musculoskeletal MRI. Ultrasonographic assessments of each affected knee were performed by one of two faculty members trained in musculoskeletal ultrasonography using a 10 to 14 MHz linear transducer. Arthroscopic evaluation of affected knees was performed by one of three faculty orthopedic surgeons to assess and record all joint pathology, which served as the reference standard for determining presence, type, and severity of meniscal pathology. All evaluators for each diagnostic modality were blinded to all other data. Data were collected and compared by a separate investigator to determine sensitivity (Sn), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), correct classification rate (CCR), likelihood ratios (LR[+] and LR[-]), and odds ratios. Preoperative ultrasonographic assessment of meniscal pathology was associated with Sn = 91.2%, Sp = 84.2%, PPV = 94.5%, NPV = 76.2%, CCR = 89.5%, LR(+) = 5.78, and LR(-) = 0.10. Preoperative MRI assessment of

  19. [Low grade renal trauma (Part II): diagnostic validity of ultrasonography].

    Science.gov (United States)

    Grill, R; Báca, V; Otcenásek, M; Zátura, F

    2010-04-01

    The aim of the study was to verify whether ultrasonography can be considered a reliable method for the diagnosis of low-grade renal trauma. The group investigated included patients with grade I or grade II blunt renal trauma, as classified by the AAST grading system, in whom ultrasonography alone or in conjunction with computed tomography was used as a primary diagnostic method. B-mode ultrasound with a transabdominal probe working at frequencies of 2.5 to 5.0 MHz was used. Every finding of post-traumatic changes in the renal tissues, i.e., post-contusion hypotonic infiltration of the renal parenchyma or subcapsular haematoma, was included. The results were statistically evaluated by the Chi-square test with the level of significance set at 5%, using Epi Info Version 6 CZ software. The group comprised 112 patients (43 women, 69 men) aged between 17 and 82 years (average, 38 years). It was possible to diagnose grade I or grade II renal injury by ultrasonography in only 60 (54%) of them. The statistical significance of ultrasonography as the only imaging method for the diagnosis of low-grade renal injury was not confirmed (p=0.543) Low-grade renal trauma is a problem from the diagnostic point of view. It usually does not require revision surgery and, if found during repeat surgery for more serious injury of another organ, it usually does not receive attention. Therefore, the macroscopic presentation of grade I and grade II renal injury is poorly understood, nor are their microscopic findings known, because during revision surgery these the traumatised kidneys are not usually removed and their injuries at autopsy on the patients who died of multiple trauma are not recorded either. The results of this study demonstrated that the validity of ultrasonography for the diagnosis of low-grade renal injury is not significant, because this examination can reveal only some of the renal injuries such as perirenal haematoma. An injury to the renal parenchyma is also indicated by

  20. Maternal hemodynamics, fetal biometry and Dopplers in pregnancies followed up for suspected fetal growth restriction.

    Science.gov (United States)

    Roberts, Llinos A; Ling, Hua Zen; Poon, Liona; Nicolaides, Kypros H; Kametas, Nikos A

    2018-04-01

    To assess whether in a cohort of patients with small for gestational age (SGA) foetuses with estimated fetal weight ≤10 th percentile, maternal hemodynamics, fetal biometry and Dopplers at presentation, can predict the subsequent development of abnormal fetal Dopplers or delivery with birthweight Cheetah), mean arterial pressure, fetal biometry, umbilical artery (UA), middle cerebral artery (MCA) and uterine artery (UT) pulsatility index (PI) and the deepest vertical pool (DVP) of amniotic fluid. Z-scores of these variables were calculated based on reported reference ranges and the values were compared between those with evidence of abnormal fetal Dopplers at presentation (group 1), those that developed abnormal Dopplers in subsequent visits (group 2) and those who did not develop abnormal Dopplers throughout pregnancy (group 3). Abnormal fetal Dopplers were defined as UAPI >95 th percentile, or MCA PI <5 th percentile. Differences in measured variables at presentation were also compared between pregnancies delivering a baby with birthweight <3 rd and ≥3 rd percentile. Multivariate logistic regression analysis was used to determine significant predictors of birthweight <3 rd percentile and evolution from normal fetal Dopplers to abnormal fetal Dopplers in groups 2 and 3. In the study population 14 (16%) cases were in group 1, 19 (22%) in group 2 and 53 (62%) in group 3. The birthweight was <3 rd percentile in 39 (45%) cases and ≥3 rd percentile in 47 (55%). In the study groups, compared to normal populations, there was decreased cardiac output and stroke volume and increased peripheral vascular resistance and mean arterial pressure (MAP) and the deviations from normal were most marked in group 1. Pregnancies with a birthweight <3 rd , compared to those ≥3 rd percentile, had higher deviations from normal in fetal biometry, maternal cardiac output, stroke volume, heart rate and peripheral vascular resistance and UT-PI. Multivariate logistic regression

  1. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The TCSP ER-2 DOPPLER RADAR (EDOP) dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of the ER-2...

  2. CAMEX-4 ER-2 DOPPLER RADAR V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-4 ER-2 Doppler Radar dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of ER-2. The...

  3. Radar micro-doppler signatures processing and applications

    CERN Document Server

    Chen, Victor C; Miceli, William J

    2014-01-01

    Radar Micro-Doppler Signatures: Processing and applications concentrates on the processing and application of radar micro-Doppler signatures in real world situations, providing readers with a good working knowledge on a variety of applications of radar micro-Doppler signatures.

  4. Numerical study of glare spot phase Doppler anemometry

    Science.gov (United States)

    Hespel, C.; Ren, K. F.; Gréhan, G.; Onofri, F.

    2008-03-01

    The phase Doppler anemometry has (PDA) been developed to measure simultaneously the velocity and the size of droplets. When the concentration of particles is high, tightly focused beams must be used, as in the dual burst PDA. The latter permits an access to the refractive index of the particle, but the effect of wave front curvature of the incident beams becomes evident. In this paper, we introduce a glare spot phase Doppler anemometry which uses two large beams. The images of the particle formed by the reflected and refracted light, known as glare spots, are separated in space. When a particle passes through the probe volume, the two parts in a signal obtained by a detector in forward direction are then separated in time. If two detectors are used the phase differences and the intensity ratios between two signals, the distance between the reflected and refracted spots can be obtained. These measured values provide information about the particle diameter and its refractive index, as well as its two velocity components. This paper is devoted to the numerical study of such a configuration with two theoretical models: geometrical optics and rigorous electromagnetism solution.

  5. Doppler speedometer for micro-organisms

    International Nuclear Information System (INIS)

    Penkov, F.; Tuleushev, A.; Lisitsyn, V.; Kim, S.; Tuleushev, Yu.

    1996-01-01

    Objective of Investigations: Development and creation of the Doppler speedometer for micro-organisms which allows to evaluate, in a real temporal scale, variations in the state of water suspension of micro-organisms under the effect of chemical, physical and other external actions. Statement of the Problem The main problem is absence of reliable, accessible for users and simple, in view of application, Doppler speedometers for micro-organisms. Nevertheless, correlation Doppler spectrometry in the regime of heterodyning the supporting and cell-scattered laser radiation is welt known. The main idea is that the correlation function of photo-current pulses bears an information on the averages over the assembly of cell velocities. For solving the biological problems, construction of auto-correlation function in the real-time regime with the delay time values comprising, function in the real-time regime with the delay time values comprising, nearly, 100 me (10 khz) or higher is needed. Computers of high class manage this problem using but the program software. Due to this, one can simplify applications of the proposed techniques provided he creates the Doppler speedometer for micro-organism on a base of the P entium . Expected Result Manufactured operable mock-up of the Doppler speedometer for micro-organisms in a form of the auxiliary computer block which allows to receive an information, in the real time scale, on the results of external effects of various nature on the cell assembly in transparent medium with a small volume of the studied cell suspension

  6. Ultrasonography evaluation during the weaning process: the heart, the diaphragm, the pleura and the lung.

    Science.gov (United States)

    Mayo, P; Volpicelli, G; Lerolle, N; Schreiber, A; Doelken, P; Vieillard-Baron, A

    2016-07-01

    On a regular basis, the intensivist encounters the patient who is difficult to wean from mechanical ventilatory support. The causes for failure to wean from mechanical ventilatory support are often multifactorial and involve a complex interplay between cardiac and pulmonary dysfunction. A potential application of point of care ultrasonography relates to its utility in the process of weaning the patient from mechanical ventilatory support. This article reviews some applications of ultrasonography that may be relevant to the process of weaning from mechanical ventilatory support. The authors have divided these applications of ultrasonography into four separate categories: the assessment of cardiac, diaphragmatic, and lung function; and the identification of pleural effusion; which can all be evaluated with ultrasonography during a dynamic process in which the intensivist is uniquely positioned to use ultrasonography at the point of care. Ultrasonography may have useful application during the weaning process from mechanical ventilatory support.

  7. The medical Doppler in hand surgery: its scientific basis, applications, and the history of its namesake, Christian Johann Doppler.

    Science.gov (United States)

    Ghori, Ahmer K; Chung, Kevin C

    2007-12-01

    The word Doppler is used synonymously in hand surgery for evaluating patency of vascular structures; however, the science and history behind the Doppler effect are not as well-known. We will present the theories behind the Doppler effect and the history of the person who made this discovery.

  8. Invasive and noninvasive assessment of pulmonic regurgitation: clinical, angiographic, phonocardiographic, echocardiographic, and Doppler ultrasound correlations.

    Science.gov (United States)

    Chandraratna, P A; Wilson, D; Imaizumi, T; Ritter, W S; Aronow, W S

    1982-06-01

    Three patients with pulmonic regurgitation and no evidence of pulmonary hypertension were investigated. These patients had low pitched diastolic murmurs which increased on inspiration, evidence of connective tissue disease as manifested by lax joints and hyperextensible skin, and marked hilar dance which extended up to the peripheral vessels. Suprasternal echocardiography revealed dilatation and increased systolic expansion of the right pulmonary artery (RPA) (25% and 28%, respectively) in two patients; the third patient had a normal RPA dimension in diastole and a marked increase in diameter (88%) in systole. Thus, these three patients demonstrated hyperdistensibility of the RPA. The spectral signal from the pulsed doppler echocardiograph showed evidence of turbulent blood flow in diastole (wide dispersion of the dots) in the right ventricular outflow tract in all three patients. This pattern was indicative of pulmonic regurgitation. In summary, the combined use of echocardiography and Doppler ultrasound is useful in the evaluation of patients with pulmonic regurgitation.

  9. Localization and Retrieval of an Eyelid Metallic Foreign Body With an Oscillating Magnet and High-Resolution Ultrasonography.

    Science.gov (United States)

    Yoo, Sylvia H; Rootman, Dan B; Goh, Alice; Savar, Aaron; Goldberg, Robert A

    2016-01-01

    A patient was found to have a metallic foreign body in the left anterior orbit on CT imaging, but the foreign body was not evident on clinical examination. On high-resolution ultrasonography, an object was identified in the left upper eyelid; however, the typical shadow with metallic foreign bodies was not seen. A high-power oscillating magnet was then applied to the eyelid, which revealed a subcutaneous metallic foreign body in the left upper eyelid. When used in conjunction, the high-resolution ultrasound and oscillating magnet successfully localized and facilitated retrieval of the metallic foreign body from the left upper eyelid.

  10. The role of contrast-enhanced ultrasonography in image-guided liver ablations

    International Nuclear Information System (INIS)

    Pescatori, Lorenzo Carlo; Sconfienza, Luca Maria; Mauri, Giovanni

    2016-01-01

    We read with great interest the paper by Kim et al. entitled “Local ablation therapy with contrast enhanced ultrasonography for hepatocellular carcinoma: a practical review,” recently published in Ultrasonography. We think that contrast-enhanced ultrasonography (CEUS), together with the development of reliable navigation systems, is likely to represent one of the most important advances in image-guided ablations in recent years. Thus, we offer some considerations on the topic

  11. Prenatal diagnosis of Beckwith-Wiedemann syndrome by two- and three-dimensional ultrasonography

    Directory of Open Access Journals (Sweden)

    Edward Araujo Junior

    2013-12-01

    Full Text Available Beckwith-Wiedemann syndrome is a genetic syndrome characterized by macroglossia, omphalocele, fetal gigantism and neonatal hypoglycemia. The authors report a case of Beckwith-Wiedemann syndrome diagnosed in a 32-year-old primigravida in whom two-dimensional ultrasonography revealed the presence of abdominal wall cyst, macroglossia and polycystic kidneys. Three-dimensional ultrasonography in rendering mode was of great importance to confirm the previous two-dimensional ultrasonography findings.

  12. Evaluation of abdominal palpation, radiography and ultrasonography for pregenancy diagnosis in bitches

    International Nuclear Information System (INIS)

    Arunmozhi, N.; Naidu, K.V.; Sreenu, M.; Rao, A.S.

    2005-01-01

    Abdominal palpation, radiography and ultrasonography were compared for pregnancy diagnosis in bitches. The earliest correct diagnosis of pregnancy was made by 22 and 21 days with abdominal palpation and ultrasonography respectively, while radiography led to more accurate diagnosis in last trimester of pregnancy. All the methods revealed 100 per cent accuracy in last trimester where as ultrasonography gave constant results from day 21 up to termination of pregnancy followed by abdominal palpation

  13. Comparison of the results of abdominal ultrasonography and exploratory laparotomy in the dog and cat.

    Science.gov (United States)

    Pastore, Gina E; Lamb, Christopher R; Lipscomb, Victoria

    2007-01-01

    Results of preoperative ultrasonography and exploratory laparotomy were reviewed retrospectively in a series of 100 small animals to assess the agreement between ultrasonographic and surgical findings and to identify abdominal lesions likely to be missed by ultrasonography. Good agreement occurred between ultrasound reports and surgical reports in 64% of the animals, which supported the use of ultrasonography in potential surgical candidates. A major discrepancy was observed between the ultrasound report and surgical findings in 25% of the animals. Of the various types of pathology encountered in the study, gastrointestinal ulceration or perforation was the most likely lesion to be missed by ultrasonography.

  14. Comparative study of scintigraphy, ultrasonography and computed tomography in the evaluation of liver tumours

    International Nuclear Information System (INIS)

    Tohyama, Junko; Ishigaki, Takeo; Ishikawa, Tsutomu

    1982-01-01

    A comparative study of scintigraphy, ultrasonography and computed tomography in 67 proven patients with clinically suspected liver tumours was reported. Scintigraphy was superior in sensitivity to ultrasonography and computed tomography. However, in specificity, scintigraphy was inferior to other two. Diagnostic efficacy of ultrasonography and computed tomography in detecting focal masses of the liver was not greatly different, and simultaneous interpretation of ultrasonogram and computed tomogram was more helpful than independent interpretation. So they were thought to be complementary. In conclusion, scintigraphy was thought to be the initial procedure in the diagnostic approach for focal liver masses and ultrasonography was second procedure because of no radiation hazards. And computed tomography should follow then. (author)

  15. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were used....... On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA......) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. RESULTS...

  16. Transcranial Doppler velocities in a large, healthy population.

    Science.gov (United States)

    Tegeler, Charles H; Crutchfield, Kevin; Katsnelson, Michael; Kim, Jongyeol; Tang, Rong; Passmore Griffin, Leah; Rundek, Tanja; Evans, Greg

    2013-07-01

    Transcranial Doppler (TCD) ultrasonography has been extensively used in the evaluation and management of patients with cerebrovascular disease since the clinical application was first described in 1982 by Aaslid and colleagues TCD is a painless, safe, and noninvasive diagnostic technique that measures blood flow velocity in various cerebral arteries. Numerous commercially available TCD devices are currently approved for use worldwide, and TCD is recognized to have an established clinical value for a variety of clinical indications and settings. Although many studies have reported normal values, there have been few recently, and none to include a large cohort of healthy subjects across age, race, and gender. As more objective, automated processes are being developed to assist with the performance and interpretation of TCD studies, and with the potential to easily compare results against a reference population, it is important to define stable normal values and variances across age, race, and gender, with clear understanding of variability of the measurements, as well as the yield from various anatomic segments. To define normal TCD values in a healthy population, we enrolled 364 healthy subjects, ages 18-80 years, to have a complete, nonimaging TCD examination. Subjects with known or suspected cerebrovascular disorders, systemic disorders with cerebrovascular effects, as well as those with known hypertension, diabetes, stroke, coronary artery disease, or myocardial infarction, were excluded. Self-reported ethnicity, handedness, BP, and BMI were recorded. A complete TCD examination was performed by a single experienced sonographer, using a single gate nonimaging TCD device, and a standardized protocol to interrogate up to 23 arterial segments. Individual Doppler spectra were saved for each segment, with velocity and pulsatility index (PI) values calculated using the instrument's automated waveform tracking function. Descriptive analysis was done to determine the mean

  17. Ultrasonographic study and Doppler flow velocimetry of maternal kidneys and liver in low-risk pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Daher, Cibele Helena; Gomes, Andrea Cavalanti; Kobayashi, Sergio; Chammas, Maria Cristina, E-mail: cibeledaher@hotmail.com [Universidade de Sao Paulo (In-Rad/HC-FMUSP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Inst. de Radiologia; Cerri, Giovanni Guido [Universidade de Sao Paulo (FMUSP), Sao Paulo, SP (Brazil). Fac. de Medicina

    2015-05-15

    Objective: longitudinal study with B-mode ultrasonography and Doppler ultrasonography of maternal kidneys and liver in low-risk pregnancy, to establish and quantify normality parameters, correlating them with physiological changes. Materials and methods: twenty-five pregnant women were assessed and selected to participate in the study, each of them undergoing four examinations at the first, second, third trimesters and postpartum. Results: findings during pregnancy were the following: increased renal volume, pyelocaliceal dilatation with incidence of 45.4% in the right kidney, and 9% in the left kidney; nephrolithiasis, 18.1% in the right kidney, 13.6% in the left kidney. With pyelocaliceal dilatation, mean values for resistivity index were: 0.68 for renal arteries; 0.66 for segmental arteries; 0.64 for interlobar arteries; 0.64 for arcuate arteries. Without pyelocaliceal dilatation, 0.67 for renal arteries; 0.64 for segmental arteries; 0.63 for interlobar arteries; and 0.61 for arcuate arteries. Portal vein flow velocities presented higher values in pregnancy, with mean value for maximum velocity of 28.9 cm/s, and 22.6 cm/s postpartum. The waveform pattern of the right hepatic vein presented changes persisting in the postpartum period in 31.8% of the patients. Cholelithiasis was observed in 18.1% of the patients. Conclusion: alterations in renal volume, pyelocaliceal dilatation, nephrolithiasis, cholelithiasis, changes in portal vein flow velocity, alterations in waveform pattern of the right hepatic vein, proved to be significant. (author)

  18. Ultrasonographic study and Doppler flow velocimetry of maternal kidneys and liver in low-risk pregnancy

    International Nuclear Information System (INIS)

    Daher, Cibele Helena; Gomes, Andrea Cavalanti; Kobayashi, Sergio; Chammas, Maria Cristina; Cerri, Giovanni Guido

    2015-01-01

    Objective: longitudinal study with B-mode ultrasonography and Doppler ultrasonography of maternal kidneys and liver in low-risk pregnancy, to establish and quantify normality parameters, correlating them with physiological changes. Materials and methods: twenty-five pregnant women were assessed and selected to participate in the study, each of them undergoing four examinations at the first, second, third trimesters and postpartum. Results: findings during pregnancy were the following: increased renal volume, pyelocaliceal dilatation with incidence of 45.4% in the right kidney, and 9% in the left kidney; nephrolithiasis, 18.1% in the right kidney, 13.6% in the left kidney. With pyelocaliceal dilatation, mean values for resistivity index were: 0.68 for renal arteries; 0.66 for segmental arteries; 0.64 for interlobar arteries; 0.64 for arcuate arteries. Without pyelocaliceal dilatation, 0.67 for renal arteries; 0.64 for segmental arteries; 0.63 for interlobar arteries; and 0.61 for arcuate arteries. Portal vein flow velocities presented higher values in pregnancy, with mean value for maximum velocity of 28.9 cm/s, and 22.6 cm/s postpartum. The waveform pattern of the right hepatic vein presented changes persisting in the postpartum period in 31.8% of the patients. Cholelithiasis was observed in 18.1% of the patients. Conclusion: alterations in renal volume, pyelocaliceal dilatation, nephrolithiasis, cholelithiasis, changes in portal vein flow velocity, alterations in waveform pattern of the right hepatic vein, proved to be significant. (author)

  19. Doppler ultrasound evaluation of cerebral blood flow pattern in neonates with congenital heart disease

    International Nuclear Information System (INIS)

    Kim, Tae Hoon; Kim, Mi Young; Kim, Yang Min; Lee, Soo Hyun; Kim, Soo Jin; Kim, Woong Han

    2003-01-01

    To evaluate intracerebral resistive index (RI) values in neonates with congenital heart disease and to investigate their changes after the corrective surgery of the congenital heart disease. Sixty nine neonates with congenital heart disease who underwent brain ultrasonography were included. Resistive index values were obtained at the genu portion of the anterior cerebral arteries through the anterior fontanelles. The patients were divided into 4 groups according to the presence of associated patent ductus arteriosus (PDA) and intracranial RI values. We evaluated the types of congenital heart disease that could influence RI values. Resistive index values were statistically higher in patients with PDA than in patients without PDA (p<0.05). RI values were higher in cases of large PDA with left-to-right shunt, but within the normal range in cases of small or nearly closing PDA or large PDA with bidirectional blood flow or with right-to-left shunt. For those patients without PDA, RI values were higher when patients had pulmonary atresia with multiple collateral vessels into the lung or when truncus arteriosus was present. RI values were also high in patients with hypoplastic left heart syndrome. RI values were normalized after the ligation of PDA, but patients with hypoplastic left heart syndrome showed persistently high RI values even after the Norwood's operation with Blalock-Taussig shunt. RI values are influenced by various congenital heart diseases except PDA. Therefore, the presences of the congenital heart disease and its hemodynamic changes should be taken into consideration in the evaluation of the intracranial RI values using Doppler ultrasonography.

  20. Ultrasonography survey and thyroid cancer in the Fukushima Prefecture

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, Peter; Kaiser, Jan Christian; Ulanovsky, Alexander [Helmholtz Zentrum Muenchen-German Research Center for Environmental Health, Department of Radiation Sciences, Institute of Radiation Protection, Neuherberg (Germany)

    2014-05-15

    Thyroid cancer is one of the major health concerns after the accident in the Fukushima Dai-ichi nuclear power station (NPS). Currently, ultrasonography surveys are being performed for persons residing in the Fukushima Prefecture at the time of the accident with an age of up to 18 years. Here, the expected thyroid cancer prevalence in the Fukushima Prefecture is assessed based on an ultrasonography survey of Ukrainians, who were exposed at an age of up to 18 years to {sup 131}I released during the Chernobyl NPS accident, and on differences in equipment and study protocol in the two surveys. Radiation risk of thyroid cancer incidence among survivors of the atomic bombings of Hiroshima and Nagasaki and preliminary estimates of thyroid dose due to the Fukushima accident were used for the prediction of baseline and radiation-related thyroid cancer risks. We estimate a prevalence of thyroid cancer of 0.027 % (95 % CI 0.010 %; 0.050 %) for the first screening campaign in the Fukushima Prefecture. Compared with the incidence rate in Japan in 2007, the ultrasonography survey is predicted to increase baseline thyroid cancer incidence by a factor of 7.4 (95 % CI 0.95; 17.3). Under the condition of continued screening, thyroid cancer during the first fifty years after the accident is predicted to be detected for about 2 % of the screened population. The prediction of radiation-related thyroid cancer in the most exposed fraction (a few ten thousand persons) of the screened population of the Fukushima Prefecture has a large uncertainty with the best estimates of the average risk of 0.1-0.3 %, depending on average dose. (orig.)

  1. [Technique of abdominal ultrasonography in newborn foals and normal findings].

    Science.gov (United States)

    Behn, C; Bostedt, H

    2000-09-01

    Under field conditions, the diagnosis of foal's diseases relies almost exclusively on the physical examination. As the signs of illness in the equine neonate are frequently vage and non-localizing, the diagnosis of diseases may be problematic. This often causes misinterpretations and leads to ineffective prophylaxis and treatment. The purpose of this study was to evaluate the usefulness of diagnostic ultrasonography of the foal's abdomen under field conditions to provide an optimized technique and to describe the normal findings. Diagnostic ultrasonography of the abdomen was performed after obtaining clinical history and passing the physical examination of 25 foals without signs of abdominal problems. The foals were scanned in a stable box, being restrained by three persons in semi-lateral recumbency. Usually, sedation was not necessary. The ventral abdominal wall was clipped, a generous amount of ultrasound coupling gel was applied and massaged on the skin surface. The ultrasonographic examination was carried out using a portable sector scanner ("Microimager 2000", Ausonics) with 5.0 and 7.5-MHz transducers or a combined 5.0 and 7.5-MHz transrectal linear-array scanner ("450 Enhanced", Pie Medical). Employing the 5.0-MHz sector scanner first, the abdomen was explored from caudal to cranial in left and right semi-lateral recumbency. The 7.5-MHz scanner was used to attain higher resolution of certain structures. The sector scanner turned out to be suitable under field conditions and adequate to examine the abdominal organs. The transrectal linear-array scanner also provided the most important informations, although it was difficult to maintain a good contact area of the scan head. By ultrasonography it was possible to identify the urinary bladder, kidneys, spleen, liver and part of the gastrointestinal tract. Thus, application of ultrasound could successfully be performed on newborn foals under field conditions.

  2. Stomach: ultrasonography evaluation and post mortem inspection in adult horses

    Directory of Open Access Journals (Sweden)

    Cristiano Chaves Pessoa da Veiga

    2014-06-01

    Full Text Available ABSTRACT. Veiga C.C.P., Cascon C.M., Souza B.G., Braga L.S.M., Souza V.C., Ferreira A.M.R. & Leite J.S. [Stomach: ultrasonography evaluation and post mortem inspection in adult horses.] Avaliação ultrassonográfica e anatomopatológica macroscópica do estômago de equinos destinados ao abate comercial. Revista Brasileira de Medicina Veterinária, 36(2:125-130, 2014. Instituto de Veterinária, Universidade Federal Rural do Rio de Janeiro, BR 465, km 7, Seropédica, 23890-000, RJ, Brasil. E-mail: radiovet@ufrrj.br The equine gastric ulcer syndrome (EGUS includes all symptomatic or asymptomatic cases of erosions, ulcers, gastritis, gastric emptying disorders, duodenitis, duodenal ulcers and complications of these disorders. Occupies a prominent place in the equine clinic where you can go for the death of the animal. Ultrasonography of the stomach is indicated when the animals showed clinical signs of gastric disease. The aim of this study was to describe the sonographic evaluation and macroscopic pathological findings of the stomach of adult horses intended for commercial slaughter. To this 39 intended for commercial slaughter horses were evaluated. Sonographic evaluation before slaughter transabdominal via the left side of abdomen for evaluation of the stomach was performed. After the slaughter of these animals their stomachs were collected, evaluated and photographed. The study concluded that ultrasonography identified the stomach in all animals evaluated, but did not allow a careful evaluation of the entire length of the viscera, especially the aglandular region and pleated border. All animals evaluated had injury to the gastric mucosa in different degrees. In animals evaluated, the stomach region was most affected by injuries glandular region, although the most severe lesions have been found in the ruffled border adjacent to aglandular region.

  3. High-resolution ultrasonography in assessing temporomandibular joint disc position.

    Science.gov (United States)

    Talmaceanu, Daniel; Lenghel, Lavinia Manuela; Bolog, Nicolae; Popa Stanila, Roxana; Buduru, Smaranda; Leucuta, Daniel Corneliu; Rotar, Horatiu; Baciut, Mihaela; Baciut, Grigore

    2018-02-04

    The purpose of this study was to determine the diagnostic value of high-resolution ultrasonography (US) in temporomandibular joint (TMJ) disc displacements. A number of 74 patients (148 TMJs) with signs and symptoms of TMJ disorders, according to the Research Diagnostic Criteria for Temporomandibular Disorders, were included in this study. All patients received US and magnetic resonance imaging (MRI) of both TMJs 1 to 5 days after the clinical examination. MRI examinations were performed using 1.5 T MRI equipment (Siemens Avanto, Siemens, Erlangen). Ultrasonographic examination was performed on a Hitachi EUB 8500 (Hitachi Medical Corp., Tokyo, Japan) scanner with L 54 M6.5-13 MHz linear transducer. MRI depicted 68 (45.95%) normal joints, 47 (31.76%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 34 (22.97%) with degenerative changes. US detected 78 (52.7%) normal joints, 37 (25%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 21 (14.19%) with degenerative changes. Compared to MRI, US showed a sensitivity of 93.1%, specificity of 87.88%, accuracy of 90.32%, a positive predictive value of 87.1% and a negative predictive value of 93.55% for overall diagnosis of disc displacement. The Youden index was 0.81. Based on our results, high-resolution ultrasonography showed high sensitivity, specificity and accuracy in the diagnosis of TMJ disc displacement. It could be a valuable imaging technique in assessing TMJ disc position. The diagnostic value of high-resolution ultrasonography depends strictly on the examiner's skills and on the equipment used.

  4. Diagnostic accuracy of the ultrasonography in complicated pregnancy

    International Nuclear Information System (INIS)

    Cha, Kyung Soo; Kim, Kun Sang; Park, Soo Soung

    1983-01-01

    Ultrasonography is an invaluable diagnostic method in Obstetrics. It provides safe, speedy and repeatable way to obtain image of normal and abnormal pregnancy. The ultrasonograms of 167 patients with suspicion of complicated pregnancy were analyzed. The results were as follows. 1. 86 patients showed normal ultrasonogram(50.9%). 100% in intrauterine fetal death and gross fetal anomaly, 100% in abnormal fetal position and number, 95% in pregnancy with pelvic mass, 83% in ectopic pregnancy, 81% in abortion, 78% in molar pregnancy, 74% in plancenta previa. 3. Ultrasonic diagnosis of abrupto placenta was difficult. 4. Diagnostic accuracy was 80% in bicornuate uterus and double vagina

  5. Clinical application of endoscopic ultrasonography for esophageal achalasia.

    Science.gov (United States)

    Minami, Hitomi; Inoue, Haruhiro; Isomoto, Hajime; Urabe, Shigetoshi; Nakao, Kazuhiko

    2015-04-01

    Endoscopic ultrasonography (EUS) has been widely used for evaluating the nature of diseases of various organs. The possibility of applying EUS for esophageal motility diseases has not been well discussed despite its versatility. At present, peroral endoscopic myotomy (POEM) for esophageal achalasia and related diseases has brought new attention to esophageal diseases because POEM provides a more direct approach to the inner structures of the esophageal wall. In the present study, we discuss the clinical utility of EUS in evaluating and treating esophageal motility diseases such as esophageal achalasia and related diseases. © 2015 The Authors. Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  6. Transcranial Doppler sonography in familial hemiplegic migraine

    International Nuclear Information System (INIS)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A.

    1991-01-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab

  7. Color Doppler US of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Bertolotto, Michele (ed.) [Trieste Univ. Ospedale di Cattinara (Italy). Dept. Radiology

    2008-07-01

    This book provides a comprehensive reference and practical guide on the application of US to penile diseases and conditions. After introductory chapters on technical requirements and penile anatomy, subsequent chapters offer a systematic overview of the diverse applications of color Doppler US. The topics covered include erectile dysfunction, Peyronie's disease, priapism, trauma, tumors, the postoperative penis, inflammation, and fibrosis. Each topic is introduced by a clinical overview with the purpose of clarifying the problems and elucidating what the urologist may expect from color Doppler US. Thereafter, performance of the US study is explained and the pathological anatomy reviewed. High-quality images obtained with high-end US equipment are included. Each chapter also contains a section on the diagnostic information provided by other imaging modalities, and in particular MRI. (orig.)

  8. Transcranial Doppler sonography in familial hemiplegic migraine

    Energy Technology Data Exchange (ETDEWEB)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A. (Universita la Sapienza, Roma (Italy))

    1991-02-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab.

  9. Renal duplex Doppler ultrasound findings in diabetics

    International Nuclear Information System (INIS)

    Shim, Hyang Yee; Kim, Young Geun; Kook, Cheol Keu; Yoon, Chong Hyun; Lee, Shin Hyung; Lee, Chang Joon

    1993-01-01

    The correlation between clinical-laboratory findings and renal duplex Doppler ultrasound findings was studied in 45 patients with diabetes mellitus to see the role of duplex Doppler ultrasound in the detection of diabetic nephropathy. The resistive indices in patients with elevated serum creatinine, BUN, proteinuria, and systolic blood pressure levels were statistically significantly higher than those in patients with normal levels (p<0.05). Also resistive indics in patients with retinopathy were higher than that in patients without retinopathy (p<0.05). But the ultrasound morphologic changes of kidney such as renal length, cortical eye-catching, and corticomedullarycontrast were not well correlated with clinical-laboratory data and resistive index. The resistive index of the kidney in conjunction with clinical-laboratory data in diabetics may be helpful in the evaluation of diabetic nephropathy

  10. Renal duplex Doppler ultrasound findings in diabetics

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Hyang Yee; Kim, Young Geun; Kook, Cheol Keu; Yoon, Chong Hyun; Lee, Shin Hyung; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    1993-12-15

    The correlation between clinical-laboratory findings and renal duplex Doppler ultrasound findings was studied in 45 patients with diabetes mellitus to see the role of duplex Doppler ultrasound in the detection of diabetic nephropathy. The resistive indices in patients with elevated serum creatinine, BUN, proteinuria, and systolic blood pressure levels were statistically significantly higher than those in patients with normal levels (p<0.05). Also resistive indics in patients with retinopathy were higher than that in patients without retinopathy (p<0.05). But the ultrasound morphologic changes of kidney such as renal length, cortical eye-catching, and corticomedullarycontrast were not well correlated with clinical-laboratory data and resistive index. The resistive index of the kidney in conjunction with clinical-laboratory data in diabetics may be helpful in the evaluation of diabetic nephropathy

  11. Colour Doppler ultrasound of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Wilkins, C.J.; Sriprasad, S.; Sidhu, P.S. E-mail: paulsidhu@compuserve.com

    2003-07-01

    Because it is a superficial structure, the penis is ideally suited to ultrasound imaging. A number of disease processes, including Peyronie's disease, penile fractures and penile tumours, are clearly visualized with ultrasound. An assessment of priapism can also be made using spectral Doppler waveform technology. Furthermore, dynamic assessment of cavernosal arterial changes after pharmaco-stimulation allows diagnosis of arterial and venogenic causes for impotence. This pictorial review illustrates the range of diseases encountered with ultrasound of the penis.

  12. Doppler Lidar Wind Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Newsom, R. K. [DOE ARM Climate Research Facility, Washington, DC (United States); Sivaraman, C. [DOE ARM Climate Research Facility, Washington, DC (United States); Shippert, T. R. [DOE ARM Climate Research Facility, Washington, DC (United States); Riihimaki, L. D. [DOE ARM Climate Research Facility, Washington, DC (United States)

    2015-07-01

    Wind speed and direction, together with pressure, temperature, and relative humidity, are the most fundamental atmospheric state parameters. Accurate measurement of these parameters is crucial for numerical weather prediction. Vertically resolved wind measurements in the atmospheric boundary layer are particularly important for modeling pollutant and aerosol transport. Raw data from a scanning coherent Doppler lidar system can be processed to generate accurate height-resolved measurements of wind speed and direction in the atmospheric boundary layer.

  13. Contrast-enhanced ultrasonography and spiral computed tomography in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Sandro; Ghittoni, Giorgia; Ravetta, Valentina; Torello Viera, Francesca; Rosa, Laura [Policlinico ' S. Matteo' Foundation, IRCCS, VI Department of Internal Medicine and Interventional Ultrasonography, Pavia (Italy); Serassi, Martina; Scabini, Mara; Vercelli, Alessandro; Calliada, Fabrizio [IRCCS Policlinico ' S. Matteo' , Department of Radiology, P.le Golgi n. 19, Pavia (Italy); Tinelli, Carmine [Biometrics Unit, IRCCS Policlinico ' S. Matteo' , Pavia (Italy); Dal Bello, Barbara [IRCCS Policlinico ' S. Matteo' , Department of Human Pathology, Pavia (Italy); Burns, Peter N. [University of Toronto, Department of Medical Biophysics, Toronto, ON (Canada); Imaging Research S660, Sunnybrook Health Science Centre, Toronto, ON (Canada)

    2008-08-15

    The aim was to compare the performances of contrast-enhanced (CE) ultrasonography (US) and spiral computed tomography (CT) in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma (HCC). We studied 50 patients with HCC who had biopsy-proven portal vein thrombi that had been detected with US and color Doppler US. Thirteen of the thrombi involved the main portal trunk and 37 the segmental branches. CEUS and CT were performed within a week of thrombus biopsies. For each imaging technique, diagnoses of thrombosis (present/absent) and thrombus nature (malignancy/benignancy) were made by experienced readers under blinded conditions and compared with pathological findings to determine accuracy rates for thrombus detection and characterization. Forty-four of the 50 thrombi were pathologically diagnosed as malignant and the remaining six were benign. CEUS detected 50/50 (100%) thrombi and correctly characterized 49/50 (98%). CT detected 34/50 (68%) thrombi and correctly characterized 23 of these 34 (68%). CEUS outperformed CT in terms of both thrombus detection (P < 0.0001) and characterization (P = 0.0001). CEUS appears to be significantly superior to CT for detection and characterization of portal vein thrombosis complicating HCC, and it should be considered in the staging of these tumors. (orig.)

  14. Ultrasonography as a prognostic and objective parameter in Achilles tendinopathy:

    DEFF Research Database (Denmark)

    Bakkegaard, Mads; Johannsen, Finn E; Højgaard, Betina

    2015-01-01

    eccentric exercises of the calf muscles and if needed supplemented with corticosteroid injections. The patients were examined clinically and by US (tendon thickness, hyper- and hypoechogenicity, calcification, bursitis, calcaneusspure, tenosynovitis, gray scale and color Doppler focusing on increased flow...... was statistically associated with a decrease in palpatory pain. CONCLUSION: Heterogeneity is a prognostic marker in AT. Tendon thickness, hypoechogenicity and increased Doppler activity can be used as objective outcome parameters for the treatment effect of AT....... intra- or peritendinous). The clinical and US examination were performed at entry, 1, 2, 3 and at 6 month. RESULTS: 42 women and 50 men were included (mean age of 47 years). They had symptoms for more than 13 months and a symptomatic Achilles tendon mean thickness of 7.4±2.3mm. Heterogeneity...

  15. Quadriceps Function and Knee Joint Ultrasonography after ACL Reconstruction.

    Science.gov (United States)

    Pamukoff, Derek N; Montgomery, Melissa M; Moffit, Tyler J; Vakula, Michael N

    2018-02-01

    Individuals with anterior cruciate ligament reconstruction (ACLR) are at greater risk for knee osteoarthritis, partially because of chronic quadriceps dysfunction. Articular cartilage is commonly assessed using magnetic resonance imaging and radiography, but these methods are expensive and lack portability. Ultrasound imaging may provide a cost-effective and portable alternative for imaging the femoral cartilage. The purpose of this study was to compare ultrasonography of the femoral cartilage between the injured and uninjured limbs of individuals with unilateral ACLR, and to examine the association between quadriceps function and ultrasonographic measures of femoral cartilage. Bilateral femoral cartilage thickness and quadriceps function were assessed in 44 individuals with unilateral ACLR. Quadriceps function was assessed using peak isometric strength, and early (RTD100) and late (RTD200) rate of torque development. Cartilage thickness at the medial femoral condyle (P accounting for time since ACLR, quadriceps peak isometric strength was associated with cartilage thickness at the medial femoral condyle (r = 0.35, P = 0.02) and femoral cartilage cross-sectional area (r = 0.28, P = 0.04). RTD100 and RTD200 were not associated with femoral cartilage thickness or cross-sectional area. Individuals with ACLR have thinner cartilage in their injured limb compared with uninjured limb, and cartilage thickness is associated with quadriceps function. These results indicate that ultrasonography may be useful for monitoring cartilage health and osteoarthritis progression after ACLR.

  16. Three-dimensional ultrasonography in the diagnosis of deep endometriosis.

    Science.gov (United States)

    Guerriero, Stefano; Saba, Luca; Ajossa, Silvia; Peddes, Cristina; Angiolucci, Marco; Perniciano, Maura; Melis, Gian Benedetto; Alcázar, Juan Luis

    2014-06-01

    In the use of 'tenderness-guided' transvaginal ultrasound, is the diagnostic accuracy of three-dimensional (3D) ultrasonography better than two-dimensional (2D) ultrasonography in the identification of deep endometriosis? Three-dimensional ultrasonography has a significantly higher diagnostic accuracy in the diagnosis of posterior locations of deep endometriosis without intestinal involvement, such as the uterosacral ligaments, vaginal and rectovaginal endometriosis. The only previous study of the diagnosis of posterior compartment endometriosis reported an poor sensitivity of 3D ultrasonography for uterosacral and sigmoid colon involvement. This diagnostic test study included 202 patients scheduled for surgery because of clinical suspicion of deep pelvic endometriosis and was carried out between January 2009 and September 2012. Modified transvaginal ultrasonography was performed on all of the women by a single examiner. Two locations of deep endometriosis were considered: intestinal involvement and other posterior lesions (including vaginal location, rectovaginal septum and uterosacral ligaments). Once the 2D ultrasonography had been performed, the 3D acquisition was performed and the obtained volume was stored. To avoid the risk of recall bias, the same operator evaluated the 3D volumes 6 months after the last examination using virtual navigation to provide a presumptive diagnosis of the presence and localization of deep endometriosis. In addition, to evaluate the reproducibility of 3D, two operators with different levels of expertise performed a retrospective review of 3D volumes from a random sample of 35 patients, twice, 1 week apart to also assess intraobserver agreement. The diagnostic performance of both tests was expressed as area under the receiver-operating characteristics curve (AUC), sensitivity, specificity, positive and negative predictive values, positive (LR+) and negative (LR-) likelihood ratios, with their respective 95% confidence interval (CI

  17. Intraoperative ultrasonography of liver, bile ducts and pancreas

    Directory of Open Access Journals (Sweden)

    Luciana Mendes de Oliveira Cerri

    Full Text Available The use of intraoperative ultrasonography (IOUS to evaluate liver, bile ducts and pancreatic disease, as compared to the results of preoperative ultrasonography and CT, is discussed. Forty-two patients who underwent abdominal surgery for suspected hepatobiliary and/or pancreatic disease were studied. The intraoperative study was carried out with a portable apparatus (Aloka 500, Japan, using 5.0 MHz and 7.5 MHz linear sterile transducers. The main indications for IOUS were the search for and/or evaluation of primary hepatic masses,hepatic abscesses or metastases, obstructive jaundice, or neuroendocrine tumors. In 15 cases (38.5 percent from the hepatobiliary group and in 7 cases (58.3 percent from the pancreatic group, a difference between preoperative and intraoperative findings was observed. The main difference was observed in relation to the number and size of hepatic and pancreatic lesions. The relationship between the lesions and the vascular structures was evaluated through IOUS. The method was also used to guide surgical procedures such as biopsies, the alcoholization of nodules, and the drainage of abscesses. IOUS plays an important role in detecting small hepatic and pancreatic nodules, in the assessment of anatomical relationships between the lesions and the vascular structures, and in the performance of interventionist procedures.

  18. Validation of equations for pleural effusion volume estimation by ultrasonography.

    Science.gov (United States)

    Hassan, Maged; Rizk, Rana; Essam, Hatem; Abouelnour, Ahmed

    2017-12-01

    To validate the accuracy of previously published equations that estimate pleural effusion volume using ultrasonography. Only equations using simple measurements were tested. Three measurements were taken at the posterior axillary line for each case with effusion: lateral height of effusion ( H ), distance between collapsed lung and chest wall ( C ) and distance between lung and diaphragm ( D ). Cases whose effusion was aspirated to dryness were included and drained volume was recorded. Intra-class correlation coefficient (ICC) was used to determine the predictive accuracy of five equations against the actual volume of aspirated effusion. 46 cases with effusion were included. The most accurate equation in predicting effusion volume was ( H  +  D ) × 70 (ICC 0.83). The simplest and yet accurate equation was H  × 100 (ICC 0.79). Pleural effusion height measured by ultrasonography gives a reasonable estimate of effusion volume. Incorporating distance between lung base and diaphragm into estimation improves accuracy from 79% with the first method to 83% with the latter.

  19. Survival Rate without Brain Abnormalities on Postnatal Ultrasonography among Monochorionic Twins after Fetoscopic Laser Photocoagulation for Selective Intrauterine Growth Restriction with Concomitant Oligohydramnios.

    Science.gov (United States)

    Ishii, Keisuke; Wada, Seiji; Takano, Mayumi; Nakata, Masahiko; Murakoshi, Takeshi; Sago, Haruhiko

    2018-02-20

    We aimed to clarify the survival rate without brain abnormalities (BA) after fetoscopic laser photoco-agulation (FLP) for monochorionic diamniotic twin gestations (MCDA) with selective intrauterine growth restriction (sIUGR) accompanied by abnormal umbilical artery (UA) Doppler waveforms and isolated oligohydramnios in the sIUGR twin. This retrospective study included 52 cases that underwent FLP. The main outcome was survival rate without BA of the twins at age 28 days. BA was defined as severe intraventricular hemorrhage and periventricular leukomalacia on postnatal ultrasonography. Median gestational age at FLP was 20 (16-24) weeks. Ten cases were classified as type III based on Doppler for the UA. For all cases, including 20 cases of anterior placenta, FLP was completed without major intraoperative complications. Amnioinfusion was required in 49 cases for better fetoscopic visualization. Fetal loss occurred in 29 sIUGR twins and two larger twins, whereas one larger twin experienced neonatal death. Survival rates without BA were 44% (n = 23) for sIUGR twins and 94% (n = 49) for the larger twins. FLP for MCDA with sIUGR presenting with oligohydramnios in the sIUGR twin might be considered a prenatal treatment option. © 2018 S. Karger AG, Basel.

  20. Ultrasound resistive index, power Doppler, and clinical parameters in established rheumatoid arthritis.

    Science.gov (United States)

    Bisi, Melissa Cláudia; do Prado, Aline Defaveri; Piovesan, Deise Marcela; Bredemeier, Markus; da Silveira, Inês Guimarães; Mendonça, José Alexandre; Staub, Henrique Luiz

    2017-04-01

    Ultrasonography (US) is a useful tool for the evaluation of sinovial vascularization and proliferation in rheumatoid arthritis (RA). Accordingly, resistive index (RI) on spectral Doppler (sD) US provides a quantitative analysis of vascular inflammation, but its utility in the evaluation of RA activity has not been established. Our objective was to determine the association of RI with other US parameters of synovitis and with clinical disease activity in established RA. Patients with positive power Doppler (pD) were included in a prospective cross-sectional study. Disease activity and disability were evaluated using the Disease Activity Score in 28-joints (DAS28) and Health Assessment Questionnaire (HAQ), respectively. Gray scale (GS) synovitis, pD, and sD analyses were performed by one of two examiners in wrists and the second and third metacarpophalangeal and proximal interphalangeal joints. The 10-joint GS and 10-joint pD scores and mean RI were then calculated. Weighted kappa (WK) values were employed to assess interobserver reability, and correlations were tested using the Spearman coefficient. Ninety-five RA patients (median duration of disease of 7 years and mean DAS28 of 4.32 ± 1.66) were included. WK values in real-time US were 0.77 for synovitis, 0.87 for pD, and 0.68 for RI. There were no significant correlations of RI with 10-joint GS, 10-joint pD, DAS28, joint counts, or HAQ (P > 0.10 for all tests). Patients in remission had a mean RI similar to those with high disease activity (0.62 ± 0.10, n = 15 versus 0.63 ± 0.13, n = 34, respectively). The addition of the RI score did not seem to improve US performance in patients with established RA.