WorldWideScience

Sample records for doppler broadening

  1. Calculation of the Doppler broadening function using Fourier analysis

    International Nuclear Information System (INIS)

    Goncalves, Alessandro da Cruz

    2010-01-01

    An efficient and precise method for calculation of Doppler broadening function is very important to obtain average group microscopic cross sections, self shielding factors, resonance integrals and others reactor physics parameter. In this thesis two different methods for calculation of Doppler broadening function and interference term will be presented. The main method is based on a new integral form for Doppler broadening function ψ(x,ζ) which gives a mathematical interpretation of the approximation proposed by Bethe and Placzek, as the convolution of the Lorentzian function with a Gaussian function. This interpretation besides leading to a new integral form for ψ(x,ζ), enables to obtain a simple analytic solution for the Doppler broadening function. (author)

  2. Application of coincidence Doppler-broadening spectroscopy to different carbon phases

    International Nuclear Information System (INIS)

    Ito, Y.; Djourelov, N.; Suzuki, T.; Kondo, K.; Ito, Y.; Shantarovich, V.; Onoe, J.

    2004-01-01

    Coincidence Doppler-broadening spectroscopy was applied to C60 and C70 fullerenes and other carbon phases, such as nanotubes and graphites. Remarkable differences were observed in the Doppler-broadening of the positron annihilation γ-rays in these materials, which reflect the different densities distribution of the momentum for electrons annihilated with positrons. This would be caused by the different composition of the π and σ electrons in annihilation with positrons. This result shows the sensitivity of the coincidence Doppler-broadening method to determine the density distribution of electrons sampled by positrons. (orig.)

  3. Research on Fast-Doppler-Broadening of neutron cross sections

    International Nuclear Information System (INIS)

    Li, S.; Wang, K.; Yu, G.

    2012-01-01

    A Fast-Doppler-Broadening method is developed in this work to broaden Continuous Energy neutron cross-sections for Monte Carlo calculations. Gauss integration algorithm and parallel computing are implemented in this method, which is unprecedented in the history of cross section processing. Compared to the traditional code (NJOY, SIGMA1, etc.), the new Fast-Doppler-Broadening method shows a remarkable speedup with keeping accuracy. The purpose of using Gauss integration is to avoid complex derivation of traditional broadening formula and heavy load of computing complementary error function that slows down the Doppler broadening process. The OpenMP environment is utilized in parallel computing which can take full advantage of modern multi-processor computers. Combination of the two can reduce processing time of main actinides (such as 238 U, 235 U) to an order of magnitude of 1∼2 seconds. This new method is fast enough to be applied to Online Doppler broadening. It can be combined or coupled with Monte Carlo transport code to solve temperature dependent problems and neutronics-thermal hydraulics coupled scheme which is a big challenge for the conventional NJOY-MCNP system. Examples are shown to determine the efficiency and relative errors compared with the NJOY results. A Godiva Benchmark is also used in order to test the ACE libraries produced by the new method. (authors)

  4. Doppler broadening of cross sections

    International Nuclear Information System (INIS)

    Buckler, P.A.C.; Pull, I.C.

    1962-12-01

    Expressions for temperature dependent cross-sections in terms of resonance parameters are obtained, involving generalisations of the conventional Doppler functions, ψ and φ. Descriptions of Fortran sub-routines, which calculate broadened cross-sections in accordance with the derived formulae, are included. (author)

  5. On the Fly Doppler Broadening Using Multipole Representation

    International Nuclear Information System (INIS)

    Khassenov, Azamat; Choi, Sooyoung; Lee, Deokjung

    2015-01-01

    On the Fly Doppler broadening is the technique to avoid pre-generation of the microscopic cross section, in other words, reduce the amount of storage. Currently, there are different types of formalisms used by NJOY code to generate reaction cross section and accomplish its Doppler broadening. Single-Level Breit-Wigner (SLBW) formalism is limited to well-separated resonances, in other words, it does not consider interference between energy levels. Multi-Level Breit- Wigner formalism (MLBW) was tested as the candidate for the cross section generation in the Monte Carlo code, which is under development in UNIST. According to the results, MLBW method requires huge amount of computational time to produce cross section at certain energy point. Reich-Moore (RM) technique can generate only 0K cross section, which means that it cannot produce broaden cross section directly from resonance parameters. The first step was to convert resonance parameters given in nuclear data file into multipoles. MPR shows very high potential to be used as the formalism in the on-the-fly Doppler broadening module of MCS. One of the main reasons is that comparison of the time cost shown in Table IV supports application of multipole representation

  6. Calculation of the Doppler broadening function using Fourier analysis;Calculo da funcao de alargamento Doppler utilizando analise de Fourier

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Alessandro da Cruz

    2010-07-01

    An efficient and precise method for calculation of Doppler broadening function is very important to obtain average group microscopic cross sections, self shielding factors, resonance integrals and others reactor physics parameter. In this thesis two different methods for calculation of Doppler broadening function and interference term will be presented. The main method is based on a new integral form for Doppler broadening function {psi}(x,{zeta}) which gives a mathematical interpretation of the approximation proposed by Bethe and Placzek, as the convolution of the Lorentzian function with a Gaussian function. This interpretation besides leading to a new integral form for {psi}(x,{zeta}), enables to obtain a simple analytic solution for the Doppler broadening function. (author)

  7. Application of Energy Window Concept in Doppler Broadening of {sup 238}U Cross Section

    Energy Technology Data Exchange (ETDEWEB)

    Khassnov, Azamat; Choi, Soo Young; Lee, Deok Jung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2014-10-15

    Currently, the NJOY code is used for construction and Doppler broadening of microscopic cross sections. There exist several methods or formalisms to produce microscopic cross sections and there are also different methods of Doppler broadening. In this paper, Multi-Level Breit-Wigner (MLBW) formalism and the Psi method are used for generation and Doppler broadening of the resonance cross section. Accuracy of the energy window concept applied MLBW (EW MLBW) Doppler broadened cross section was compared with that of the cross section generated by conventional MLBW (Con MLBW) formalism for {sup 2}38U isotope using MATLAB. The conventional method requires Doppler broadening of all resonances, including resonances far from the target energy point, which do not change much with respect to the temperature change. The energy window concept makes Doppler broadening possible with a smaller number of resonances neighboring to the energy point we are interested in, and just adds up 0 K temperature cross sections of other resonances. Multi-level Breit-Wigner formalism and the Doppler broadening method were used to construct microscopic cross sections of {sup 238}U at different temperatures. The energy window concept was applied only for the 1st resonance energy region (4.5∼11.2 eV). The energy window concept demonstrates high competitiveness because the relative differences were less than 0.0016% for all types of cross sections. The advantage of the energy window concept is that the number of resonances broadened for every energy point is significantly reduced, which allows a reduction of computation time by almost 45 % of Doppler broadening time of the cross section generation at temperatures higher than 0 K.

  8. Homogenization of Doppler broadening in spin-noise spectroscopy

    Science.gov (United States)

    Petrov, M. Yu.; Ryzhov, I. I.; Smirnov, D. S.; Belyaev, L. Yu.; Potekhin, R. A.; Glazov, M. M.; Kulyasov, V. N.; Kozlov, G. G.; Aleksandrov, E. B.; Zapasskii, V. S.

    2018-03-01

    The spin-noise spectroscopy, being a nonperturbative linear optics tool, is still reputed to reveal a number of capabilities specific to nonlinear optics techniques. The effect of the Doppler broadening homogenization discovered in this work essentially widens these unique properties of spin-noise spectroscopy. We investigate spin noise of a classical system—cesium atoms vapor with admixture of buffer gas—by measuring the spin-induced Faraday rotation fluctuations in the region of D 2 line. The line, under our experimental conditions, is strongly inhomogeneously broadened due to the Doppler effect. Despite that, optical spectrum of the spin-noise power has the shape typical for the homogeneously broadened line with a dip at the line center. This fact is in stark contrast with the results of previous studies of inhomogeneous quantum dot ensembles and Doppler broadened atomic systems. In addition, the two-color spin-noise measurements have shown, in a highly spectacular way, that fluctuations of the Faraday rotation within the line are either correlated or anticorrelated depending on whether the two wavelengths lie on the same side or on different sides of the resonance. The experimental data are interpreted in the frame of the developed theoretical model which takes into account both kinetics and spin dynamics of Cs atoms. It is shown that the unexpected behavior of the Faraday rotation noise spectra and effective homogenization of the optical transition in the spin-noise measurements are related to smallness of the momentum relaxation time of the atoms as compared with their spin-relaxation time. Our findings demonstrate abilities of spin-noise spectroscopy for studying dynamic properties of inhomogeneously broadened ensembles of randomly moving spins.

  9. Narrowing of electromagnetically induced transparency resonance in a Doppler-broadened medium

    International Nuclear Information System (INIS)

    Javan, Ali; Kocharovskaya, Olga; Lee Hwang; Scully, Marlan O.

    2002-01-01

    We derive an analytic expression for the linewidth of electromagnetically induced transparency (EIT) resonance in a Doppler-broadened system. It is shown here that for relatively low intensity of the driving field the EIT linewidth is proportional to the square root of intensity and is independent of the Doppler width, similar to the laser-induced line narrowing effect described by Feld and Javan. In the limit of high intensity we recover the usual power-broadening case where the EIT linewidth is proportional to the intensity and inversely proportional to the Doppler width

  10. Doppler broadening measurements in FRX-C/LSM

    International Nuclear Information System (INIS)

    Baron, M.H.; Chrien, R.E.

    1989-01-01

    Measurements obtained in situ during field reversed configuration (FRC) formation show that the Doppler broadening ion temperature T CV is larger by a factor of two or more than the ion temperature T i derived from pressure balance and Thomson scattering. After a time comparable to an ion-ion equilibrium time, T CV and T i come into agreement with each other. An exception to this picture occurs in the lowest fill pressure condition (2 mtorr), for which T CV > T i is maintained throughout the FRC lifetime. Earlier Doppler broadening measurements in FRX-B and FRX-C also showed persistent, anomalously high T CV at low fill pressure. The initially high values of T CV are probably caused by convective motion generated by the radial implosion. The low fill pressure results suggest an enhanced ohmic power input to the carbon ions. 7 refs., 3 figs

  11. Doppler-broadening of positron annihilation in a biological environment

    International Nuclear Information System (INIS)

    Torrisi, L.; La Mela, C.; Catania, Univ.

    1997-01-01

    The aim of this study was to investigate the Doppler effect of the 511 keV γ peak from positron annihilation in biological matter: The broadening of the annihilation peak is due to positron annihilation with electrons that have high momentum. In aqueous solutions annihilation depends on the temperature and it is linked positronium formation. Measurements in vivo, on human brain, were taken during the diagnosis of positron emission tomography (PET) on healthy patients by injecting them with the beta emitter of short lifetime 18F . The Doppler-broadening in biological tissues rich in water content decreased significantly compared to biological solutions and water

  12. Development and validation of the fast doppler broadening module coupled within RMC code

    International Nuclear Information System (INIS)

    Yu Jiankai; Liang Jin'gang; Yu Ganglin; Wang Kan

    2015-01-01

    It is one of the efficient approach to reduce the memory consumption in Monte Carlo based reactor physical simulations by using the On-the-fly Doppler broadening for temperature dependent nuclear cross sections. RXSP is a nuclear cross sections processing code being developed by REAL team in Department of Engineering Physics in Tsinghua University, which has an excellent performance in Doppler broadening the temperature dependent continuous energy neutron cross sections. To meet the dual requirements of both accuracy and efficiency during the Monte Carlo simulations with many materials and many temperatures in it, this work enables the capability of on-the-fly pre-Doppler broadening cross sections during the neutron transport by coupling the Fast Doppler Broaden module in RXSP code embedded in the RMC code also being developed by REAL team in Tsinghua University. Additionally, the original OpenMP-based parallelism has been successfully converted into the MPI-based framework, being fully compatible with neutron transport in RMC code, which has achieved a vast parallel efficiency improvement. This work also provides a flexible approach to solve Monte Carlo based full core depletion calculation with many temperatures feedback in many isotopes. (author)

  13. SIGMA1-2007, Doppler Broadening ENDF Format Linear-Linear. Interpolated Point Cross Section

    International Nuclear Information System (INIS)

    2007-01-01

    1 - Description of problem or function: SIGMA-1 Doppler broadens evaluated Cross sections given in the linear-linear interpolation form of the ENDF/B Format to one final temperature. The data is Doppler broadened, thinned, and output in the ENDF/B Format. IAEA0854/15: This version include the updates up to January 30, 2007. Changes in ENDF/B-VII Format and procedures, as well as the evaluations themselves, make it impossible for versions of the ENDF/B pre-processing codes earlier than PREPRO 2007 (2007 Version) to accurately process current ENDF/B-VII evaluations. The present code can handle all existing ENDF/B-VI evaluations through release 8, which will be the last release of ENDF/B-VI. 2 - Modifications from previous versions: Sigma-1 VERS. 2007-1 (Jan. 2007): checked against all ENDF/B-VII; increased page size from 60,000 to 360,000 energy points 3 - Method of solution: The energy grid is selected to ensure that the broadened data is linear-linear interpolable. SIGMA-1 starts from the free-atom Doppler broadening equations and adds the assumptions of linear data within the table and constant data outside the range of the table. If the Original data is not at zero Kelvin, the data is broadened by the effective temperature difference to the final temperature. If the data is already at a temperature higher than the final temperature, Doppler broadening is not performed. 4 - Restrictions on the complexity of the problem: The input to SIGMA-1 must be data which vary linearly in energy and cross section between tabulated points. The LINEAR program provides such data. LINEAR uses only the ENDF/B BCD Format tape and copies all sections except File 3 as read. Since File 3 data are in identical Format for ENDF/B Versions I through VI, the program can be used with all these versions. - The present version Doppler broadens only to one final temperature

  14. An exact formalism for Doppler-broadened neutron cross-sections

    International Nuclear Information System (INIS)

    Catsaros, Nicolas.

    1985-07-01

    An exact formalism (Ψ, Φ) is proposed for the calculation of Breit-Wigner or Adler-Adler Doppler-broadened neutron cross-sections. The well-known (Ψ, Φ) formalism is shown to be a zero-order approximation of the generalized (Ψ, Φ) formalism. (author)

  15. Relationship between electromagnetically-induced transparency and Autler–Townes splitting in a Doppler-broadened system

    International Nuclear Information System (INIS)

    Pei Li-Ya; Qu Yi-Zhi; Niu Jin-Yan; Wang Ru-Quan; Zuo Zhan-Chun; Wu Ling-An; Fu Pan-Ming

    2015-01-01

    We study the relationship between electromagnetically-induced transparency (EIT) and Autler–Townes (AT) splitting in a cascade three-level Doppler-broadened system. By comparing the absorption spectrum with the fluorescence excitation spectrum, it is found that for a Doppler-broadened system, EIT resonance cannot be explained as the result of quantum interference, unlike the case of a homogeneously broadened system. Instead, the macroscopic polarization interference plays an important role in determining the spectra of EIT and AT splitting, which can be explained within the same framework when being detected by the absorption spectra. (paper)

  16. A new formulation for the Doppler broadening function relaxing the approximations of Beth–Plackzec

    International Nuclear Information System (INIS)

    Palma, Daniel A.P.; Gonçalves, Alessandro C.; Martinez, Aquilino S.; Mesquita, Amir Z.

    2016-01-01

    Highlights: • One of the Beth–Placzek approximation were relaxed. • An additional term in the form of an integral is obtained. • A new mathematical formulation for the Doppler broadening function is proposed. - Abstract: In all nuclear reactors some neutrons can be absorbed in the resonance region and, in the design of these reactors, an accurate treatment of the resonant absorptions is essential. Apart from that, the resonant absorption varies with fuel temperature due to the Doppler broadening of the resonances. The thermal agitation movement in the reactor core is adequately represented in the microscopic cross-section of the neutron-core interaction through the Doppler broadening function. This function is calculated numerically in modern systems for the calculation of macro-group constants, necessary to determine the power distribution of a nuclear reactor. It can also be applied to the calculation of self-shielding factors to correct the measurements of the microscopic cross-sections through the activation technique and used for the approximate calculations of the resonance integrals in heterogeneous fuel cells. In these types of application we can point at the need to develop precise analytical approximations for the Doppler broadening function to be used in the calculation codes that calculate the values of this function. However, the Doppler broadening function is based on a series of approximations proposed by Beth–Plackzec. In this work a relaxation of these approximations is proposed, generating an additional term in the form of an integral. Analytical solutions of this additional term are discussed. The results obtained show that the new term is important for high temperatures.

  17. Doppler and time-travel broadening in ICR plasma isotope separation

    International Nuclear Information System (INIS)

    Karchevskii, A.I.; Potanin, E.P.

    1994-01-01

    Isotopically-selective ion-cyclotron resonance (ICR) heating is one of the most promising plasma isotope separation methods. The separation degree of ICR separation in a plasma depends on the resonance heating selectivity. The selectivity is due to the isotopically-adjacent accelerated ions resonance curve overlapping and therefore, is determined by the width of the resonance curves. In the case of a collisionless plasma in an ideal homogeneous longitudinal magnetic field, the line broadening is mainly determined by Doppler and time-travel effects. These effects differ in nature, and one has some difficulties in distinguishing them when interpreting the resonance curves because both broadenings depend on ion axial velocities. We consider the simplest case: the extrenal heating alternating electric field does not depend on the axial coordinate (the wave number γ = 0). Hence, in this case the Doppler effect does not occur

  18. Creation of problem-dependent Doppler-broadened cross sections in the KENO Monte Carlo code

    International Nuclear Information System (INIS)

    Hart, Shane W.D.; Celik, Cihangir; Maldonado, G. Ivan; Leal, Luiz

    2016-01-01

    Highlights: • A quick method of Doppler broadening one- and two-dimensional cross sections has been added to KENO. • The method uses a finite difference method to broaden data to user defined temperatures. • Various problems and benchmarks were run to showcase results. • Results with the Doppler broadened cross sections are closer to benchmark results. - Abstract: This paper introduces a quick method for improving the accuracy of Monte Carlo simulations by generating one- and two-dimensional cross sections at a user-defined temperature before performing transport calculations. A finite difference method is used to Doppler-broaden cross sections to the desired temperature, and unit-base interpolation is done to generate the probability distributions for double differential two-dimensional thermal moderator cross sections at any arbitrarily user-defined temperature. The accuracy of these methods is tested using a variety of contrived problems. In addition, various benchmarks at elevated temperatures are modeled, and results are compared with benchmark results. The problem-dependent cross sections are observed to produce eigenvalue estimates that are closer to the benchmark results than those without the problem-dependent cross sections.

  19. Coincidence Doppler broadening study on hydrocarbons with pi and sigma valence electrons: positronium correction

    International Nuclear Information System (INIS)

    Djourelov, N.; Suzuki, T.; Yu, R.S.; Ito, Y.

    2005-01-01

    The coincidence Doppler broadening (CDB) technique was applied to study the electron momentum distribution in anthracene, diphenyl, naphthalene, and polystyrene. A method for separation of the positron and positronium (Ps) components from the Doppler-broadened annihilation line (DBAL) was developed further to be applicable to hydrocarbons with different π and σ valence electron distributions. This method allows extraction of the electron momentum distribution (EMD) from DBAL for samples when Ps formation occurs. The annihilation on π valence electrons was detected as broadening of the EMD compared to that obtained for a polymer sample only with σ valence electrons. The broadening appeared as a significant change in the shape of the CDB ratio of the corresponding positronium-corrected curves: a slight enhancement above the unity line in the low-momentum region and a drop in the momentum region, 10-20x10 -3 m o c

  20. A new expression for doppler broadening function based on Fourier Cosine Transform

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Alessandro da C.; Martinez, Aquilino S.; Silva, Fernando C. da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mails: agoncalves@con.ufrj.br; aquilino@lmp.ufrj.br; fernando@con.ufrj.br

    2007-07-01

    The main objective of this paper consists of the derivation of an analytical solution for the Doppler broadening function {psi} ({xi}, x). The analytical solution is derived from a new integral expression for the {psi} ({xi}, x) function, which can be interpreted as a Fourier cosine transform. The expression obtained for {psi} ({xi}, x) in terms of elementary functions, proved quite simple and accurate, leading to a similar solution obtained through the differential equation for the {psi} ({xi}, x) function, using the methods of Frobenius and of parameter variation. The Doppler broadening function is widely used in applications related to the treatment of nuclear resonances, calculations of multigroup parameters and resonance self-shielding factors, and to correct microscopic cross section measurements through the activation technique. (author)

  1. A new expression for doppler broadening function based on Fourier Cosine Transform

    International Nuclear Information System (INIS)

    Goncalves, Alessandro da C.; Martinez, Aquilino S.; Silva, Fernando C. da

    2007-01-01

    The main objective of this paper consists of the derivation of an analytical solution for the Doppler broadening function Ψ (ξ, x). The analytical solution is derived from a new integral expression for the Ψ (ξ, x) function, which can be interpreted as a Fourier cosine transform. The expression obtained for Ψ (ξ, x) in terms of elementary functions, proved quite simple and accurate, leading to a similar solution obtained through the differential equation for the Ψ (ξ, x) function, using the methods of Frobenius and of parameter variation. The Doppler broadening function is widely used in applications related to the treatment of nuclear resonances, calculations of multigroup parameters and resonance self-shielding factors, and to correct microscopic cross section measurements through the activation technique. (author)

  2. Macroscopic effects in electromagnetically-induced transparency in a Doppler-broadened system

    International Nuclear Information System (INIS)

    Pei Li-Ya; Qu Yi-Zhi; Niu Jin-Yan; Wang Ru-Quan; Wu Ling-An; Fu Pan-Ming; Zuo Zhan-Chun

    2015-01-01

    We study the electromagnetically-induced transparency (EIT) in a Doppler-broadened cascaded three-level system. We decompose the susceptibility responsible for the EIT resonance into a linear and a nonlinear part, and the EIT resonance reflects mainly the characteristics of the nonlinear susceptibility. It is found that the macroscopic polarization interference effect plays a crucial role in determining the EIT resonance spectrum. To obtain a Doppler-free spectrum there must be polarization interference between atoms of different velocities. A dressed-state model, which analyzes the velocities at which the atoms are in resonance with the dressed states through Doppler frequency shifting, is employed to explain the results. (paper)

  3. Point defects in MnSi and YBCO studied by Doppler Broadening Spectroscopy using a positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Reiner, Markus

    2015-10-28

    The positron beam NEPOMUC was used in order to investigate MnSi and YBa{sub 2}Cu{sub 3}O{sub 7-δ} (YBCO) single crystals. The Doppler broadening of the annihilation radiation of electron-positron pairs was analyzed. Thus, the concentration of Mn vacancies in MnSi crystals was determined. In thin YBCO films, the Doppler broadening is correlated with the oxygen deficiency δ. Its spatial distribution and its high-temperature behavior were studied using positrons.

  4. Gamma-ray induced doppler broadening

    International Nuclear Information System (INIS)

    Robinson, S.J.

    1992-01-01

    The ultra high resolving power of the GAMS4 double-flat crystal spectrometer (M.S. Dewey et al Nucl. Instrum. Methods A 284 (1989) 151.) has been used to observe the Doppler broadening of gamma-rays emitted by nuclei recoiling at speeds as low as 10 -6 c. Such recoils may be induced by the previous emission of gamma-radiation following thermal neutron capture. If the population mechanism of an excited state is known (or can be approximated) and the slowing down mechanism can be modeled, then this technique can be used to extract the lifetime of excited nuclear states. The combination of this technique and the neutron capture reaction allows the study of states which cannot necessarily be accessed by other means. This has allowed the resolution of a number of long standing questions in low-spin nuclear structure. The basis of the technique is discussed and a number of examples given

  5. Theoretical study of electromagnetically induced transparency in a five-level atom and application to Doppler-broadened and Doppler-free Rb atoms

    International Nuclear Information System (INIS)

    Bhattacharyya, Dipankar; Ray, Biswajit; Ghosh, Pradip N

    2007-01-01

    We report theoretical studies of a Λ-type five-level atomic system. The density matrix equations are set up and solved numerically to obtain the probe absorption line shape of Rb D 2 transitions for cold (Doppler-free) and room temperature (Doppler-broadened) atoms. Simulated spectra for Doppler-broadened systems lead to four velocity-selective dips along with an electromagnetic induced transparency (EIT) peak as observed earlier from the co-propagating pump-probe spectroscopy of Rb D 2 transitions. Effects of pump power and spontaneous decay rate from the upper levels on the simulated spectra are also studied. For cold atoms a very pronounced EIT peak is observed when the pump frequency is on resonance with one allowed transition. We find that lower pump power leads to a much sharper EIT signal in this case. A simulated dispersion curve shows a rapid variation of the refractive index that may lead to a sharp reduction of the group velocity of photons

  6. Calculation of the Doppler broadening of the electron-positron annihilation radiation in defect-free bulk materials

    International Nuclear Information System (INIS)

    Ghosh, V. J.; Alatalo, M.; Asoka-Kumar, P.; Nielsen, B.; Lynn, K. G.; Kruseman, A. C.; Mijnarends, P. E.

    2000-01-01

    Results of a calculation of the Doppler broadening of the positron-electron annihilation radiation and positron lifetimes in a large number of elemental defect-free materials are presented. A simple scheme based on the method of superimposed atoms is used for these calculations. Calculated values of the Doppler broadening are compared with experimental data for a number of elemental materials, and qualitative agreement is obtained. These results provide a database which can be used for characterizing materials and identifying impurity-vacancy complexes. (c) 2000 The American Physical Society

  7. Covariance Matrix of a Double-Differential Doppler-Broadened Elastic Scattering Cross Section

    Science.gov (United States)

    Arbanas, G.; Becker, B.; Dagan, R.; Dunn, M. E.; Larson, N. M.; Leal, L. C.; Williams, M. L.

    2012-05-01

    Legendre moments of a double-differential Doppler-broadened elastic neutron scattering cross section on 238U are computed near the 6.67 eV resonance at temperature T = 103 K up to angular order 14. A covariance matrix of these Legendre moments is computed as a functional of the covariance matrix of the elastic scattering cross section. A variance of double-differential Doppler-broadened elastic scattering cross section is computed from the covariance of Legendre moments. Notice: This manuscript has been authored by UT-Battelle, LLC, under contract DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes.

  8. Theoretical evaluation of the Doppler broadening contribution to the angular resolution in CdZnTe Compton scattering detector

    International Nuclear Information System (INIS)

    Diaz Garcia, A.; Cabal Rodriguez, A.E.; Rubio Rodriguez, J. A.; Salicio Diez, J.; Perez Morales, J.M.; Vela Morales, O.; Willmott Zappacosta, C.; Van Espen, P.

    2011-01-01

    Electronically collimated Compton Cameras have been tested in Single Photon Emission Tomography (SPECT) systems instead of mechanically collimated gamma detectors in order to improve their limited sensitivity. One of the main factors that contribute to the worsening of the angular resolution and thus to the deterioration of the system spatial resolution is Doppler broadening. Double differential Klein-Nishina equation is used to consider the random movement of electron inside the crystal. It is important to perform this analysis for each particular material because is difficult to infer one simple Doppler broadening dependency of the atomic number Z. In high Z materials the internal electrons are strongly linked to the nucleus and therefore there can be found high momentums, but they represent just a small portion of the electrons that suffers Compton scattering. This work estimates the influence of the Doppler broadening in CdZnTe semiconductor for different incoming photon energies. For this means there are analyzed main Compton broadening processes in semiconductor Cd 0,8 Zn 0,2 Te with density ρ=5,85g/cm 3 . (Author)

  9. Linear and nonlinear light propagations in a Doppler-broadened medium via electromagnetically induced transparency

    International Nuclear Information System (INIS)

    Li Liang; Huang Guoxiang

    2010-01-01

    We present a systematic theoretical study to deal with linear and nonlinear light propagations in a Doppler-broadened three-level Λ system via electromagnetically induced transparency (EIT), with incoherent population exchange between two lower energy levels taken into account. Through a careful analysis of base state and linear excitation, we show that the EIT condition of the system is given by |Ω c | 2 γ 31 >>2γ 21 Δω D 2 , where Ω c is half the Rabi frequency of the control field, Δω D is the Doppler width, and γ jl is the decay rate of the coherence between states |j> and |l>. Under this condition, the effect of incoherent population exchange is insignificant, while dephasing dominates the decoherence of the system. This condition also ensures the validity of the weak nonlinear perturbation theory used in this work for solving the Maxwell-Bloch equations with inhomogeneous broadening. We then investigate the nonlinear propagation of the probe field and show that it is possible to form temporal optical solitons in the Doppler-broadened medium. Such solitons have ultraslow propagating velocity and can be generated in very low light power. The possibility of realizing (1+1)-dimensional and (2+1)-dimensional spatial optical solitons in the adiabatic regime of the system is also discussed.

  10. Optimized coincidence Doppler broadening spectroscopy using deconvolution algorithms

    International Nuclear Information System (INIS)

    Ho, K.F.; Ching, H.M.; Cheng, K.W.; Beling, C.D.; Fung, S.; Ng, K.P.

    2004-01-01

    In the last few years a number of excellent deconvolution algorithms have been developed for use in ''de-blurring'' 2D images. Here we report briefly on one such algorithm we have studied which uses the non-negativity constraint to optimize the regularization and which is applied to the 2D image like data produced in Coincidence Doppler Broadening Spectroscopy (CDBS). The system instrumental resolution functions are obtained using the 514 keV line from 85 Sr. The technique when applied to a series of well annealed polycrystalline metals gives two photon momentum data on a quality comparable to that obtainable using 1D Angular Correlation of Annihilation Radiation (ACAR). (orig.)

  11. New approximations for the Doppler broadening function applied to the calculation of resonance self-shielding factors

    International Nuclear Information System (INIS)

    Palma, Daniel A.; Goncalves, Alessandro C.; Martinez, Aquilino S.; Silva, Fernando C.

    2008-01-01

    The activation technique allows much more precise measurements of neutron intensity, relative or absolute. The technique requires the knowledge of the Doppler broadening function ψ(x,ξ) to determine the resonance self-shielding factors in the epithermal range G epi (τ,ξ). Two new analytical approximations for the Doppler broadening function ψ(x,ξ) are proposed. The approximations proposed are compared with other methods found in literature for the calculation of the ψ(x,ξ) function, that is, the 4-pole Pade method and the Frobenius method, when applied to the calculation of G epi (τ,ξ). The results obtained provided satisfactory accuracy. (authors)

  12. New approximations for the Doppler broadening function applied to the calculation of resonance self-shielding factors

    Energy Technology Data Exchange (ETDEWEB)

    Palma, Daniel A. [CEFET QUIMICA de Nilopolis/RJ, Rio de Janeiro (Brazil); Goncalves, Alessandro C.; Martinez, Aquilino S.; Silva, Fernando C. [COPPE/UFRJ - Programa de Engenharia Nuclear, Rio de Janeiro (Brazil)

    2008-07-01

    The activation technique allows much more precise measurements of neutron intensity, relative or absolute. The technique requires the knowledge of the Doppler broadening function psi(x,xi) to determine the resonance self-shielding factors in the epithermal range G{sub epi} (tau,xi). Two new analytical approximations for the Doppler broadening function psi(x,xi) are proposed. The approximations proposed are compared with other methods found in literature for the calculation of the psi(x,xi) function, that is, the 4-pole Pade method and the Frobenius method, when applied to the calculation of G{sub epi} (tau,xi). The results obtained provided satisfactory accuracy. (authors)

  13. Verification of the accuracy of Doppler broadened, self-shielded multigroup cross sections for fast power reactor applications

    International Nuclear Information System (INIS)

    Ganesan, S.; Gopalakrishnan, V.; Ramanadhan, M.M.; Cullen, D.E.

    1988-01-01

    Verification results for Doppler broadening and self-shielding are presented. One of the important results presented is that the original SIGMA1 method of numerical Doppler broadening has now been demonstrated to be inaccurate and not capable of producing results to within required accuracies. Fortunately, due to this study, the SIGMA1 method has been significantly improved and the new SIGMA1 is now capable of producing results to within required accuracies. Although this paper presents results based upon using only one code system, it is important to realize that the original SIGMA1 method is presently used in many cross-section processing code systems; the results of this paper indicate that unless these other code systems are updated to include the new SIGMA1 method, the results produced by these code systems could be very inaccurate. The objectives of the IAEA nuclear data processing code verification project are reviewed as well as the requirements for the accuracy of calculation of Doppler coefficients and the present status of these calculations. The initial results of Doppler broadening and self-shielding calculations are presented and the inconsistency of the results which led to the discovery of errors in the original SIGMA1 method of Doppler broadening are pointed out. Analysis of the errors found and improvements in the SIGMA1 method are presented. Improved results are presented in order to demonstrate that the new SIGMA1 method can produce results within required accuracies. Guidelines are presented to limit the uncertainty introduced due to cross-section processing in order to balance available computer resources to accuracy requirements. Finally cross-section processing code users are invited to participate in the IAEA processing code verification project in order to verify the accuracy of their calculated results. (author)

  14. Digital spectrometer for coincidence measurement of Doppler broadening of positron annihilation radiation

    International Nuclear Information System (INIS)

    Cizek, J.; Vlcek, M.; Prochazka, I.

    2010-01-01

    High-resolution digital coincidence Doppler broadening spectrometer equipped with two high-purity Ge detectors and two-channel 12-bit fast digitizer was developed and tested in this work. Two configurations were compared: (i) semi-digital setup which uses active analogue shaping of detector pulses prior to digitization to improve signal-to-noise ratio, and (ii) pure-digital setup which samples detector pulses directly. Software procedure developed for analysis of sampled waveforms, i.e. precise determination of energy of detected photon and rejection of distorted pulses, is described. Performance of digital coincidence spectrometer was compared with traditional analogue setup connected to the same detectors. It was found that digital spectrometer enables to achieve better energy resolution than in traditional analogue setup. Moreover, in digital configuration one has better control over shape of the signal. This allows efficient elimination of undesired distorted or damaged waveforms and to obtain spectrum of better clarity. The superior parameters of new digital coincidence Doppler broadening spectrometer are demonstrated by benchmark measurements of well defined Fe and Al specimens and also by the detection of rare annihilation in flight events.

  15. Approximation of the Doppler broadening function by Frobenius method

    International Nuclear Information System (INIS)

    Palma, Daniel A.P.; Martinez, Aquilino S.; Silva, Fernando C.

    2005-01-01

    An analytical approximation of the Doppler broadening function ψ(x,ξ) is proposed. This approximation is based on the solution of the differential equation for ψ(x,ξ) using the methods of Frobenius and the parameters variation. The analytical form derived for ψ(x,ξ) in terms of elementary functions is very simple and precise. It can be useful for applications related to the treatment of nuclear resonances mainly for the calculations of multigroup parameters and self-protection factors of the resonances, being the last used to correct microscopic cross-sections measurements by the activation technique. (author)

  16. Refinements of On-The-Fly Doppler Broadening via Gauss-Hermite Quadrature in Monte Carlo Reactor Analysis

    International Nuclear Information System (INIS)

    Jo, YuGwon; Cho, Nam Zin

    2017-01-01

    In this paper, the GHQ algorithm is refined in two aspects. One is that the Doppler broadened cross section in the low energy range is estimated by the two variations of GHQ (GHQ1 and GHQ2) and the two-point GLQ for both accuracy and computational efficiency. The other is a refined cross-section table lookup procedure for GHQ to reduce computing times. For the low energy range (y < 4), the effective cross section is estimated by the GHQ2 algorithm to improve both accuracy and computational efficiency. To further reduce the computing times for Doppler broadening, a procedure of cross-section table lookups for the GHQ algorithm is also refined. From the numerical results, we have shown that the GHQ2 algorithm removes oscillatory errors in the low energy range, which appear in the GHQ1 algorithm, while the computing time of the GHQ2 algorithm is much faster than that of the two-point GLQ algorithm. In conclusion, the “GHQ2/GHQ” algorithm (GHQ2 for y < 4 and GHQ for y ≥4) with the refined cross-section table lookup procedure can be an efficient and accurate OTF Doppler broadening algorithm for MC simulations, when the cross section data is piecewise linearly tabulated.

  17. Kramers–Kronig relation in a Doppler-broadened Λ-type three-level system

    International Nuclear Information System (INIS)

    Wang Meng; Lu Xiao-Gang; Bai Jin-Hai; Miao Xing-Xu; Gao Yan-Lei; Wu Ling-An; Fu Pan-Ming; Wang Ru-Quan; Zuo Zhan-Chun; Pei Li-Ya; Yang Shi-Ping; Pang Zhao-Guang

    2015-01-01

    We measure the absorption and dispersion in a Doppler-broadened Λ-type three level system by resonant stimulated Raman spectroscopy with homodyne detection. Through studying the dressed state energies of the system, it is found that the absorption and dispersion satisfy the Kramers–Kronig relation. The absorption and dispersion spectra calculated by employing this relation agree well with our experimental observations. (rapid communication)

  18. Solitary waves of surface plasmon polariton via phase shifts under Doppler broadening and Kerr nonlinearity

    Science.gov (United States)

    Ahmad, S.; Ahmad, A.; Bacha, B. A.; Khan, A. A.; Abdul Jabar, M. S.

    2017-12-01

    Surface Plasmon Polaritons (SPPs) are theoretically investigated at the interface of a dielectric metal and gold. The output pulse from the dielectric is used as the input pulse for the generation of SPPs. The SPPs show soliton-like behavior at the interface. The solitary form of a SPP is maintained under the effects of Kerr nonlinearity, Doppler broadening and Fresnel dragging whereas its phase shift is significantly modified. A 0.3radian phase shift is calculated in the presence of both Kerr nonlinearity and Fresnel dragging in the absence of plasma motion. The phase shift is enhanced to 60radian due to the combined effect of Doppler broadening, Kerr nonlinearity and Fresnel dragging. The results may have significant applications in nano-photonics, optical tweezers, photovoltaic devices, plasmonster and sensing technology.

  19. Gamma-ray induced Doppler broadening and the determination of lifetimes of excited nuclear states

    International Nuclear Information System (INIS)

    Boerner, H.G.; Jolie, J.; Robinson, S.J.; Kessler, E.G.; Dewey, S.M.; Greene, G.; Deslattes, R.; Ulbig, S.; Lieb, K.P.; Casten, R.F.; Krusche, B.; Cizewski, J.A.

    1990-01-01

    Measurements of lifetimes of excited states in nuclei yield crucial information for sensitive tests of nuclear models. Here a novel method will be discussed which involves the GRID (Gamma Ray Induced Doppler broadening) technique, in which Doppler broadening is observed in a transition from a nucleus recoiling from the emission of a previous gamma ray. As the recoil energy is extremely small, ultra-high energy resolving power has to be used. To date all such experiments have been carried out at ILL using the GAMS4 double flat crystal spectrometer which is operated in a NIST-ILL collaboration. The method can be used for all lifetimes below a few picoseconds. The wide range of applicability, together with the very exhaustive set of data often obtained, is an advantage with respect to many other methods. The characteristic features of GRID will be discussed using some selected examples. 21 refs., 8 figs

  20. Preliminary performance evaluation of on-the-fly doppler broadening capability for Monte Carlo simulation in MCS

    International Nuclear Information System (INIS)

    Khassenov, A.; Choi, S.; Lee, H.; Zhang, P.; Zheng, Y.; Lee, D.

    2015-01-01

    This paper examines multipole representation of the cross section and its further Doppler broadening at the resolved resonance region. At the first step, a conversion is performed from nuclear data file resonance parameters to multipoles, which are corresponding poles and residues. The application of multipole representation allows generating the cross section at the target temperature, without pre-generation of 0K cross section libraries. In order to reduce the computational time for cross section generation, window energy concept was implemented and tested. On-the-fly Doppler broadening module based on multipole and windowed multipole representations were implemented into Monte Carlo code, and a pin cell problem was simulated. Simulation time and multiplication factors for different cases were compared with original Monte Carlo simulation results. (author)

  1. Characterization of ion-irradiated ODS Fe–Cr alloys by doppler broadening spectroscopy using a positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Parente, P.; Leguey, T. [Departamento de Física and IAAB, Universidad Carlos III de Madrid, 28911 Leganés (Spain); Castro, V. de, E-mail: vanessa.decastro@uc3m.es [Departamento de Física and IAAB, Universidad Carlos III de Madrid, 28911 Leganés (Spain); Gigl, T.; Reiner, M.; Hugenschmidt, C. [FRM II and Physics Department, Technische Universität München, 85747 Garching (Germany); Pareja, R. [Departamento de Física and IAAB, Universidad Carlos III de Madrid, 28911 Leganés (Spain)

    2015-09-15

    The damage profile of oxide dispersion strengthened steels after single-, or simultaneous triple-ion irradiation at different conditions has been characterized using a low energy positron beam in order to provide information on microstructural changes induced by irradiation. Doppler broadening and coincident Doppler broadening measurements of the positron annihilation line have been performed on different Fe–Cr–(W,Ti) alloys reinforced with Y{sub 2}O{sub 3}, to identify the nature and stability of irradiation-induced open-volume defects and their possible association with the oxide nanoparticles. It was found that irradiation induced vacancy clusters are associated with Cr atoms. The results are of highest interest for modeling the damage induced by 14 MeV neutrons in reduced activation Fe–Cr alloys relevant for fusion devices.

  2. Characterization of ion-irradiated ODS Fe–Cr alloys by doppler broadening spectroscopy using a positron beam

    International Nuclear Information System (INIS)

    Parente, P.; Leguey, T.; Castro, V. de; Gigl, T.; Reiner, M.; Hugenschmidt, C.; Pareja, R.

    2015-01-01

    The damage profile of oxide dispersion strengthened steels after single-, or simultaneous triple-ion irradiation at different conditions has been characterized using a low energy positron beam in order to provide information on microstructural changes induced by irradiation. Doppler broadening and coincident Doppler broadening measurements of the positron annihilation line have been performed on different Fe–Cr–(W,Ti) alloys reinforced with Y 2 O 3 , to identify the nature and stability of irradiation-induced open-volume defects and their possible association with the oxide nanoparticles. It was found that irradiation induced vacancy clusters are associated with Cr atoms. The results are of highest interest for modeling the damage induced by 14 MeV neutrons in reduced activation Fe–Cr alloys relevant for fusion devices

  3. The derivation of the Doppler broadening function using Frobenius method

    International Nuclear Information System (INIS)

    Palma, Daniel A.P.; Martinez, Aquilino S.; Silva, Fernando C.

    2006-01-01

    An analytical approximation of the Doppler broadening function ψ(ξ,x) is proposed. This approximation is based on the solution of the differential equation for ψ(ξ,x) using the methods of Frobenius and parameters variation. The analytical form derived for ψ(ξ,x) in terms of elementary functions is very simple and precise. It can be useful for applications related to the treatment of nuclear resonances, mainly for calculations of multigroup parameters and resonances self-protection factors, the latter being used to correct microscopic cross section measurements by the activation technique. (author)

  4. Quantum Interference between Autonomous Single-Photon Sources from Doppler-Broadened Atomic Ensemble

    OpenAIRE

    Jeong, Teak; Lee, Yoon-Seok; Park, Jiho; Kim, Heonoh; Moon, Han Seb

    2017-01-01

    To realize a quantum network based on quantum entanglement swapping, bright and completely autonomous sources are essentially required. Here, we experimentally demonstrate Hong-Ou-Mandel (HOM) quantum interference between two independent bright photon pairs generated via the spontaneous four-wave mixing in Doppler-broadened ladder-type 87Rb atoms. Bright autonomous heralded single photons are operated in a continuous-wave (CW) mode with no synchronization or supplemental filters. The four-fol...

  5. Chemical analysis using coincidence Doppler broadening and supporting first-principles theory: Applications to vacancy defects in compound semiconductors

    International Nuclear Information System (INIS)

    Makkonen, I.; Rauch, C.; Mäki, J.-M.; Tuomisto, F.

    2012-01-01

    The Doppler broadening of the positron annihilation radiation contains information on the chemical environment of vacancy defects trapping positrons in solids. The measured signal can, for instance, reveal impurity atoms situated next to vacancies. As compared to integrated quantities such as the positron annihilation rate or the annihilation line shape parameters, the full Doppler spectrum measured in the coincidence mode contains much more useful information for defect identification. This information, however, is indirect and complementary understanding is needed to fully interpret the results. First-principles calculations are a valuable tool in the analysis of measured spectra. One can construct an atomic-scale model for a given candidate defect, calculate from first principles the corresponding Doppler spectrum, and directly compare results between experiment and theory. In this paper we discuss recent examples of successful combinations of coincidence Doppler broadening measurements and supporting first-principles calculations. These demonstrate the predictive power of state-of-the-art calculations and the usefulness of such an approach in the chemical analysis of vacancy defects.

  6. On-the-fly doppler broadening for Monte Carlo codes

    International Nuclear Information System (INIS)

    Yesilyurt, G.; Martin, W. R.; Brown, F. B.

    2009-01-01

    A methodology to allow on-the-fly Doppler broadening of neutron cross sections for use in Monte Carlo codes has been developed. The Monte Carlo code only needs to store 0 K cross sections for each isotope and the method will broaden the 0 K cross sections for any isotope in the library to any temperature in the range 77 K-3200 K. The methodology is based on a combination of Taylor series expansions and asymptotic series expansions. The type of series representation was determined by investigating the temperature dependence of U3o8 resonance cross sections in three regions: near the resonance peaks, mid-resonance, and the resonance wings. The coefficients for these series expansions were determined by a regression over the energy and temperature range of interest. Since the resonance parameters are a function of the neutron energy and target nuclide, the ψ and χ functions in the Adler-Adler multi-level resonance model can be represented by series expansions in temperature only, allowing the least number of terms to approximate the temperature dependent cross sections within a given accuracy. The comparison of the broadened cross sections using this methodology with the NJOY cross sections was excellent over the entire temperature range (77 K-3200 K) and energy range. A Monte Carlo code was implemented to apply the combined regression model and used to estimate the additional computing cost which was found to be less than <1%. (authors)

  7. Effect of optical pumping on absorption spectra for the doppler broadened rubidium

    International Nuclear Information System (INIS)

    Shin, Seo Ro; Noh, Heung Ryoul

    2008-01-01

    The absorption of a laser beam in the Doppler broadened atomic vapor cell is one of the simplest problems in atomic physics. Although many reports on theoretical and experimental studies of linear absorption have been reported, the effect of optical pumping on the absorption coefficient has not been studied in detail. In this presentation, we present a theoretical and experimental study on linear absorption for the Doppler broadened rubidium vapor cell. The absorption coefficient of a σ"+"(or π)polarized laser beam was calculated as a function of the laser frequency for the various laser intensities. The calculated results were compared with the experimental results. Figure 1(a) shows the calculated absorption coefficient of the π polarized laser beam for the transition F"g"=1→F"e"=0,1,2 of the "87"Rb atom. The diameter of the laser beam was 3mm and the intensity was I=0 and I=0.1I"8"(I"8"=16.2W/m"2"). The peak values for various intensities are shown in Fig. 1(b). We found that the absorption coefficient for the transition from the lower hyperfine state decreased with the increased laser intensity, whereas that for the transition from the upper hyperfine state increased(decreased)for the σ"+"(π)polarized laser beam

  8. Doppler broadening measurements of positron annihilation spectroscopy using a 22 Na source made in IFIN-HH Bucharest

    International Nuclear Information System (INIS)

    Racolta, P.M.; Craciun, L.; Plostinaru, D.; Catana, D.; Muresan, O.; Serban, A.

    2003-01-01

    The Doppler-broadening technique requires an energy-dispersive system. Compared with the angular correlation technique, a compact and relatively simple setup is possible and, thus spectrometers are used in almost all positron laboratories. The energy broadening of the annihilation line is measured by a high-resolution energy-dispersive detector system. The paper describes the principia of this method, experimental arrangement used, and data treatment. (authors)

  9. Electromagnetically induced transparency in thermal Rydberg atoms: superatom model with finite Doppler broadening

    Science.gov (United States)

    Bai, Si-Yin; Bao, Qian-Qian; Tian, Xue-Dong; Liu, Yi-Mou; Wu, Jin-Hui

    2018-04-01

    We study the steady optical responses of a cold atomic ensemble driven into the three-level ladder configuration involving a Rydberg state at finite temperatures. By improving the superatom model with thermal movement included, we calculate relevant atomic coherence effects and find that the residual Doppler broadening at the mK-K temperatures will weaken the nonclassical properties of transmitted probe photons. Furthermore, propagation directions of the probe and coupling fields have a great influence on various properties related to electromagnetically induced transparency. That is, the residual Doppler effect is more destructive to relevant atomic coherence effects in the co-propagation case but can be partially eliminated in the counter-propagation case.

  10. Doppler broadened positron annihilation studies in YBa2Cu3Osub(7-x)

    International Nuclear Information System (INIS)

    Pujari, P.K.; Manohar, S.B.; Datta, T.; Prakash, S.; Gopalakrishnan, I.K.; Sastry, P.V.P.S.S.; Phatak, G.M.; Iyer, R.M.

    1988-01-01

    DBAR (Doppler Broadened Positron Annihilation Radiation) has been measured as a function of temperature in a superconducting (orthorhombic) and a nonsuperconducting (tetragonal) YBCO compound. Each spectrum is deconvoluted off the instrumental resolution function and analysed using PAACFIT. An electronic structural change leading to higher momentum state of the oxygen valence electron and increase in electron density at the oxygen vacancy sites are suggested. (author)

  11. Determination of the Ion Velocity Distribution in a Rotating Plasma from Measurements of Doppler Broadening

    DEFF Research Database (Denmark)

    Jørgensen, L. W.; Sillesen, Alfred Hegaard

    1979-01-01

    The Doppler-broadened profile of the He II 4685.75 AA line was measured along a chord in a rotating plasma, transverse to the magnetic field. Using a single-particle orbit picture, the corresponding velocity spectrum of ions confirm the measurements, so it can be concluded that the single-particl...

  12. Solution of the Doppler broadening function based on the fourier cosine transform

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Alessandro da C [COPPE/UFRJ - Programa de Engenharia Nuclear, Universidade Federal do Rio de Janeiro, P.O. Box 68509, 21941-914 Rio de Janeiro, RJ (Brazil)], E-mail: agoncalves@con.ufrj.br; Martinez, Aquilino S.; Silva, Fernando C. da [COPPE/UFRJ - Programa de Engenharia Nuclear, Universidade Federal do Rio de Janeiro, P.O. Box 68509, 21941-914 Rio de Janeiro, RJ (Brazil)

    2008-10-15

    This paper provides a new integral representation for the Doppler broadening function {psi}({xi}, x), which is interpreted as being a Fourier cosine transform. This integral form allows the obtaining of an analytical solution in a simple and accurate functional manner as regards the elementary functions. The solution obtained through the new integral representation can be widely used in several applications such as the calculation of self-shielding factors and measurement corrections for the microscopic cross section through the activation technique.

  13. Solution of the Doppler broadening function based on the fourier cosine transform

    International Nuclear Information System (INIS)

    Goncalves, Alessandro da C; Martinez, Aquilino S.; Silva, Fernando C. da

    2008-01-01

    This paper provides a new integral representation for the Doppler broadening function ψ(ξ, x), which is interpreted as being a Fourier cosine transform. This integral form allows the obtaining of an analytical solution in a simple and accurate functional manner as regards the elementary functions. The solution obtained through the new integral representation can be widely used in several applications such as the calculation of self-shielding factors and measurement corrections for the microscopic cross section through the activation technique

  14. Positron mobility in thermally grown SiO2 measured by Doppler broadening technique

    International Nuclear Information System (INIS)

    Kong, Y.; Leung, T.C.; Asoka-Kumar, P.; Nielsen, B.; Lynn, K.G.

    1991-01-01

    The positron mobility in thermally grown SiO 2 is deduced from Doppler broadening lineshape data on a metal-oxide-semiconductor sample for positrons implanted into the oxide layer. The fitted mobility is ∼13(10)x10 -3 cm 2 /s V. This value is between that of the electron and hole mobilities in the same system and is two orders of magnitude smaller than the previous estimate from positron measurements

  15. Doppler Broadening of In-Flight Positron Annihilation Radiation due to Electron Momentum

    International Nuclear Information System (INIS)

    Hunt, A. W.; Cassidy, D. B.; Sterne, P. A.; Cowan, T. E.; Howell, R. H.; Lynn, K. G.; Golevchenko, J. A.

    2001-01-01

    We report the first observation of electron momentum contributions to the Doppler broadening of radiation produced by in-flight two-photon annihilation in solids. In these experiments an approximately 2.5 MeV positron beam impinged on thin polyethylene, aluminum, and gold targets. Since energetic positrons easily penetrate the nuclear Coulomb potential and do not cause a strong charge polarization, the experimental annihilation line shapes agree well with calculations based on a simple independent-particle model. Moreover, annihilations with the deepest core electrons are greatly enhanced

  16. Ion temperature measurements of turbulently heated TRIAM-1 plasmas by the Doppler-broadening of visible lines

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, N; Nakamura, K; Toi, K; Itoh, S [Kyushu Univ., Fukuoka (Japan). Research Inst. for Applied Mechanics

    1980-07-01

    The ion temperature of the turbulently heated TRIAM-1 plasma is obtained from the Doppler-broadening of visible lines. The radial profiles of the volume emission of visible lines are measured beforehand to examine whether the volume emissions are localized at a specified position of the minor cross-section of the plasma or not. The ion temperature of the specified position is determined from these profiles. The time behaviour of thus obtained Doppler ion temperature shows a good agreement with that of the one derived from the Neutral Energy Analyzer.

  17. Doppler Broadening Calculations of Compton Scattering for Molecules, Plastics, Tissues, and Few Biological Materials in the X-Ray Region: An Analysis in Terms of Compton Broadening and Geometrical Energy Broadening

    Science.gov (United States)

    Rao, D. V.; Cesareo, R.; Brunetti, A.; Gigante, G. E.; Akatsuka, T.; Takeda, T.; Itai, Y.

    2004-09-01

    Relativistic and nonrelativistic Compton profile cross sections for H, C, N, O, P, and Ca and for a few important biological materials such as water, polyethylene, lucite, polystyrene, nylon, polycarbonate, bakelite, fat, bone and calcium hydroxyapatite are estimated for a number of Kα x-ray energies and for 59.54 keV (Am-241) γ photons. Energy broadening and geometrical broadening (ΔG) is estimated by assuming θmin and θmax are symmetrically situated around θ=90°. FWHM of J(PZ) and FWHM of Compton energy broadening are evaluated at various incident photon energies. These values are estimated around the centroid of the Compton profile with an energy interval of 0.1 and 1.0 keV for 59.54 keV photons. Total Compton, individual shell, and Compton energy-absorption scattering cross sections are evaluated in the energy region from 0.005 to 0.5 MeV. It is an attempt to know the effect of Doppler broadening for single atoms, many of which constitute the biological materials.

  18. Compact extended model for doppler broadening of neutron absorption resonances in solids

    International Nuclear Information System (INIS)

    Villanueva, A. J; Granada, J.R

    2009-01-01

    We present a simplified compact model for calculating Doppler broadening of neutron absorption resonances in an incoherent Debye solid. Our model extends the effective temperature gas model to cover the whole range of energies and temperatures, and reduces the information of the dynamical system to a minimum content compatible with a much better accuracy of the calculation. This model is thus capable of replacing the existing algorithm in standard codes for resonance cross sections preparation aimed at neutron and reactor physics calculations. The model is applied to the 238 U 6.671 eV effective broadened cross section. We also show how this model can be used for thermometry in an improved fashion compared to the effective temperature gas model. Experimental data of the same resonance at low and high temperatures are also shown and the performances of each model are put to the test on this basis. [es

  19. Positron life time and annihilation Doppler broadening measurements on transition metal complexes

    International Nuclear Information System (INIS)

    Levay, B.; Burger, K.

    1982-01-01

    Positron life time and annihilation Doppler broadening measurements have been carried out on 44 solid coordination compounds. Several correlations have been found between the annihilation life time (tau 1 ) and line shape parameters (L) and the chemical structure of the compounds. Halide ligands were the most active towards positrons. This fact supports the assumption on the possible formation of [e + X - ] positron-halide bound state. The life time was decreasing and the annihilation energy spectra were broadening with the increasing negative character of the halides. The aromatic base ligands affected the positron-halide interaction according to their basicity and space requirement and thus they indirectly affected the annihilation parameters, too. In the planar and tetrahedral complexes the electron density on the central met--al ion affected directly the annihilation parameters, while in the octahedral mixed complexes it had only an ind--irect effect through the polarization of the halide ligands. (author)

  20. Ion temperature measurements of turbulently heated tokamak plasma by Doppler-broadening of visible lines in TRIAM-1

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, N; Nakamura, K; Toi, K; Itoh, S [Kyushu Univ., Fukuoka (Japan). Research Inst. for Applied Mechanics

    1981-01-01

    In the turbulent heating experiment of the high-field tokamak TRIAM-1, the bulk ion heating shown by the neutral energy analyzer measurement is confirmed by the Doppler broadening measurement of visible lines. The increasing rate and decay time of the Doppler ion temperature are almost the same as those derived from the neutral energy analyzer measurement. From both methods of ion temperature measurements, it is shown that the ion temperature has a parabolic profile within 50 ..mu..s after the application of the heating pulse.

  1. Software for analysis of waveforms acquired by digital Doppler broadening spectrometer

    International Nuclear Information System (INIS)

    Vlcek, M; Čížek, J; Procházka, I

    2013-01-01

    High-resolution digital spectrometer for coincidence measurement of Doppler broadening of positron annihilation radiation was recently developed and tested. In this spectrometer pulses from high purity Ge (HPGe) detectors are sampled in the real time by fast digitizers and subsequently analyzed off-line by software. We present description of the software routines used for pulse shape analysis in two spectrometer configurations: (i) semi-digital setup in which detector pulses shaped in spectroscopic amplifiers (SA's) are digitized; (ii) pure digital setup in which pulses from detector pre-amplifiers are digitized directly. Software developed in this work will be freely available in the form of source code and pre-compiled binaries.

  2. Vacancy defects in electron-irradiated ZnO studied by Doppler broadening of annihilation radiation

    Science.gov (United States)

    Chen, Z. Q.; Betsuyaku, K.; Kawasuso, A.

    2008-03-01

    Vacancy defects in ZnO induced by electron irradiation were characterized by the Doppler broadening of annihilation radiation measurements together with the local density approximation calculations. Zinc vacancies (VZn) are responsible for positron trapping in the as-irradiated state. These are annealed out below 200°C . The further annealing at 400°C results in the formation of secondary defects attributed to the complexes composed of zinc vacancies and zinc antisites (VZn-ZnO) .

  3. Design for measurement system of Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with the Ge detector

    International Nuclear Information System (INIS)

    Mori, Kazuteru; Uedono, Akira; Tanigawa, Shoichiro; Nakai, Katsuhiko

    1998-01-01

    The measurement system for Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with a Ge detector was developed. The principle of measurement system with the coincidence technique between the NaI detector and the Ge detector was described. Application of the system for the detection of vacancy-type defects introduced by electron irradiation in Czochralski-(Cz) grown Si was shown. Detail in the difference between the Doppler broadening profiles for Cz-Si and Si grown by the floating-zone method was also obtained. (author)

  4. Design for measurement system of Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with the Ge detector

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Kazuteru; Uedono, Akira; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Nakai, Katsuhiko

    1998-08-01

    The measurement system for Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with a Ge detector was developed. The principle of measurement system with the coincidence technique between the NaI detector and the Ge detector was described. Application of the system for the detection of vacancy-type defects introduced by electron irradiation in Czochralski-(Cz) grown Si was shown. Detail in the difference between the Doppler broadening profiles for Cz-Si and Si grown by the floating-zone method was also obtained. (author)

  5. Deconvolution of 2D coincident Doppler broadening spectroscopy using the Richardson-Lucy algorithm

    International Nuclear Information System (INIS)

    Zhang, J.D.; Zhou, T.J.; Cheung, C.K.; Beling, C.D.; Fung, S.; Ng, M.K.

    2006-01-01

    Coincident Doppler Broadening Spectroscopy (CDBS) measurements are popular in positron solid-state studies of materials. By utilizing the instrumental resolution function obtained from a gamma line close in energy to the 511 keV annihilation line, it is possible to significantly enhance the quality of the CDBS spectra using deconvolution algorithms. In this paper, we compare two algorithms, namely the Non-Negativity Least Squares (NNLS) regularized method and the Richardson-Lucy (RL) algorithm. The latter, which is based on the method of maximum likelihood, is found to give superior results to the regularized least-squares algorithm and with significantly less computer processing time

  6. Integrated system for production of neutronics and photonics calculational constants. Volume 21, Part C, Program SIGMAL (version 79-1): Doppler-broaden evaluated cross sections in the Livermore-Evaluated Nuclear Data Library (ENDL) format

    International Nuclear Information System (INIS)

    Cullen, D.E.

    1979-01-01

    A code, SIGMAL, to Doppler-broaden evaluated cross sections in the ENDL format was designed. This code can Doppler-broaden cross sections that result from neutrons, protons, deuterons, tritons, 3 He, or alpha particles incident on any target nuclei. The code allows broadening to up to 100 final temperatures, either directly from the initial temperature or by bootstrapping to successively higher temperatures. 6 figures, 2 tables

  7. Study of Doppler broadened annihilation spectra in zinc and zinc-containing 0.05 at. % iron

    International Nuclear Information System (INIS)

    Troev, T.; Zolov, R.; Dimova, V.; Levay, B.

    1979-01-01

    The Doppler broadening of annihilation gamma spectra obtained from positron-electron annihilation in pure polycrystalline zinc and zinc-containing 0.05 at. % iron have been investigated. The line shapes were measured by a Ge(Li) detector in coincidence with a NaI(Tl) scintillation detector. The results are quite consistent with those expected from the trapping model. The positrons are trapped by impurity atoms and vacancy-impurity pairs in zinc containing 0.05 at. % iron. (author)

  8. Approximation of the Doppler broadening function by Frobenius method; Aproximacao da funcao de alargamento doppler atraves do metodo de Frobenius

    Energy Technology Data Exchange (ETDEWEB)

    Palma, Daniel A.P. [Centro Federal de Educacao Tecnologica de Quimica de Nilopolis/RJ (CEFET), RJ (Brazil)]. E-mail: dpalma@cefeteq.br; Martinez, Aquilino S.; Silva, Fernando C. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mail: aquilino@lmp.ufrj.br; fernando@lmn.con.ufrj.br

    2005-07-01

    An analytical approximation of the Doppler broadening function {psi}(x,{xi}) is proposed. This approximation is based on the solution of the differential equation for {psi}(x,{xi}) using the methods of Frobenius and the parameters variation. The analytical form derived for {psi}(x,{xi}) in terms of elementary functions is very simple and precise. It can be useful for applications related to the treatment of nuclear resonances mainly for the calculations of multigroup parameters and self-protection factors of the resonances, being the last used to correct microscopic cross-sections measurements by the activation technique. (author)

  9. Some Notes on Neutron Up-Scattering and the Doppler-Broadening of High-Z Scattering Resonances

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, Donald Kent [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-28

    When neutrons are scattered by target nuclei at elevated temperatures, it is entirely possible that the neutron will actually gain energy (i.e., up-scatter) from the interaction. This phenomenon is in addition to the more usual case of the neutron losing energy (i.e., down-scatter). Furthermore, the motion of the target nuclei can also cause extended neutron down-scattering, i.e., the neutrons can and do scatter to energies lower than predicted by the simple asymptotic models. In recent years, more attention has been given to temperature-dependent scattering cross sections for materials in neutron multiplying systems. This has led to the inclusion of neutron up-scatter in deterministic codes like Partisn and to free gas scattering models for material temperature effects in Monte Carlo codes like MCNP and cross section processing codes like NJOY. The free gas scattering models have the effect of Doppler Broadening the scattering cross section output spectra in energy and angle. The current state of Doppler-Broadening numerical techniques used at Los Alamos for scattering resonances will be reviewed, and suggestions will be made for further developments. The focus will be on the free gas scattering models currently in use and the development of new models to include high-Z resonance scattering effects. These models change the neutron up-scattering behavior.

  10. Revisiting the four-level inverted-Y system under both Doppler-free and Doppler-broadened conditions: an analytical approach

    International Nuclear Information System (INIS)

    Ghosh, Arindam; Islam, Khairul; Bandyopadhyay, Amitava; Bhattacharyya, Dipankar

    2016-01-01

    We report the occurrence of electromagnetically induced transparency (EIT) in the simulated probe response signal for a four-level inverted-Y type system that is being acted upon by a weak coherent probe field, a strong coherent pump field and a coherent repump field. There are two ground energy levels, one intermediate energy level and one uppermost energy level. The weak probe field couples the lowest ground level to the intermediate level whereas the repump field connects the other ground level with the intermediate level. The strong control field couples the intermediate level with the uppermost energy level, thereby forming an inverted-Y type system. The density matrix based theoretical model has been developed and solved analytically for this four-level system and the probe response signal has been simulated at different values of the control and repump Rabi frequencies, control and repump frequency detunings and under both Doppler-free and Doppler-broadened conditions using the parameters of 87 Rb D 2 transition. Extremely low line width (few tens of kHz) for the EIT signal has been noticed under thermal averaging for copropagating probe, control and repump field configuration. The EIT signal is found to be immune to the variation in the control Rabi frequency. (paper)

  11. Three-gamma annihilation of ortho-positronium in NiO/γ-Al2O3 catalysts detected by positron lifetime and coincidence Doppler broadening measurements

    International Nuclear Information System (INIS)

    Huang, S.H.; Chen, Z.Q.; Zhang, H.J.

    2012-01-01

    The pore structure of NiO/γ-Al 2 O 3 catalysts is characterized by positron lifetime and Doppler broadening measurements. A very long lifetime τ 4 of 92 ns is resolved from the positron lifetime spectrum measured for pure Al 2 O 3 , which could be attributed to the ortho-positronium (o-Ps) lifetime in large pores. It was also found that the fitted lifetime τ 4 and its corresponding intensity I 4 obtained from the lifetime spectra both decrease with narrowing energy window of the stop channel in the fast–fast coincidence lifetime measurement system. This suggests that the ultra long lifetime is primarily due to the self annihilation of o-Ps which emits three gamma-rays. Such 3γ annihilation is further evidenced by measuring the Doppler broadening of annihilation gamma rays in coincidence with the prompt gamma rays (1.28 MeV) emitted from the 22 Na positron source. In NiO/γ-Al 2 O 3 catalysts both the lifetime τ 4 and its intensity I 4 decreases with increasing NiO content (from 3 wt% to 40 wt%), which indicates decreasing of the number of 3γ events. The 3γ annihilation parameter analyzed from the coincidence Doppler broadening spectrum shows consistent decrease with increasing NiO content. - Highlights: ► Above paper reported study of the 3-gamma annihilation of o-Ps. ► 3γ annihilation was verified by varying the energy window of the lifetime system. ► A new coincidence Doppler broadening technique is also used to record 3γ events. ► 3γ parameter decreases with NiO content in NiO/γ-Al 2 O 3 catalysts.

  12. Program SIGMA1 (version 79-1): Doppler broaden evaluated cross sections in the evaluated nuclear data file/version B (ENDF/B) format

    International Nuclear Information System (INIS)

    Cullen, D.E.

    1979-01-01

    Program SIGMA1 Doppler-broadens evaluated cross sections in the ENDF/B format. The program requires that input cross sections be tabulated as linearly interpolable functions of energy in ENDF/B File 3; broadened cross sections, in this same form, replace the original values in the output tape. This report describes the methods used in the code and serves as a user's guide. A listing of the source deck is available on request

  13. The deconvolution of Doppler-broadened positron annihilation measurements using fast Fourier transforms and power spectral analysis

    International Nuclear Information System (INIS)

    Schaffer, J.P.; Shaughnessy, E.J.; Jones, P.L.

    1984-01-01

    A deconvolution procedure which corrects Doppler-broadened positron annihilation spectra for instrument resolution is described. The method employs fast Fourier transforms, is model independent, and does not require iteration. The mathematical difficulties associated with the incorrectly posed first order Fredholm integral equation are overcome by using power spectral analysis to select a limited number of low frequency Fourier coefficients. The FFT/power spectrum method is then demonstrated for an irradiated high purity single crystal sapphire sample. (orig.)

  14. Pre-precipitation studies in an Al-Zn alloy by positron Doppler broadening measurements

    International Nuclear Information System (INIS)

    Panchanadeeswaran, S.; Plichta, M.R.; Byrne, J.G.

    1984-01-01

    Positron annihilation studies using measurements of Doppler broadening of annihilation γ-rays have been carried out in an Al-8.5 wt% Zn alloy. More than 90% of positron trapping is believed to occur at GP zones formed on quenching the supersaturated solid solution. The dissolution of GP zones above 373 K was revealed by drastic narrowing of the Doppler energy spectrum for samples aged above 373 K. The kinetics of formation of GP zones at ambient temperatures is drastically reduced when the alloy containing GP zones formed during quenching from supersaturated solid solution was reverted at 403 K and reaged at ambient temperature. It was also observed that, even after long reageing, the total number of GP zones formed is much lower than in a directly quenched alloy. The kinetics of formation of GP zones are also reduced by quenching from a single phase to an intermediate temperature where GP zones are not stable, followed by ageing at ambient temperature. Transmission electron micrographs revealed the presence of dislocation loops in alloys quenched from temperature above 773 K. The sensitivity of positrons to the presence of dislocation loops was analysed using the R parameter analysis. (author)

  15. The influence of radiation and light on Ps formation in PMMA and PE studied by coincidence Doppler-broadening spectroscopy

    CERN Document Server

    Suzuki, T; Shantarovich, V; Kondo, K; Hamada, E; Matso, M; Ma Li; Ito, Y

    2003-01-01

    Using two Ge detectors, the high-resolution Doppler-broadening energy spectra of positron annihilation gamma rays has been obtained by measuring the coincidences of the two photons. Light bleaching and oxygen effects on positron annihilation were investigated in this way. A large enhancement of the high-momentum part of the coincidence Doppler spectra was observed in poly(methylmethacrylate) (PMMA), which contains oxygen atoms in the polymer structure. Bleaching experiments in PMMA and in copolymer ethylene-methylmethacrylate EMMA (LDPE+MMA 3 mol%) have demonstrated that the enhancement effect may be due to the trapping of positrons by the polar -C sup + 6-O sup - groups, followed by positron annihilation with the electrons belonging to oxygen.

  16. Integrated system for production of neutronics and photonics calculational constants. Volume 21, Part C, Program SIGMAL (version 79-1): Doppler-broaden evaluated cross sections in the Livermore-Evaluated Nuclear Data Library (ENDL) format. [In FORTRAN IV for CDC 7600

    Energy Technology Data Exchange (ETDEWEB)

    Cullen, D.E.

    1979-03-17

    A code, SIGMAL, to Doppler-broaden evaluated cross sections in the ENDL format was designed. This code can Doppler-broaden cross sections that result from neutrons, protons, deuterons, tritons, /sup 3/He, or alpha particles incident on any target nuclei. The code allows broadening to up to 100 final temperatures, either directly from the initial temperature or by bootstrapping to successively higher temperatures. 6 figures, 2 tables.

  17. Synthetic model for Doppler broadening of neutron absorption resonances in molecular fluids

    Energy Technology Data Exchange (ETDEWEB)

    Villanueva, Alejandro J., E-mail: villanueva@cab.cnea.gov.a [Comision Nacional de Energia Atomica, Centro Atomico Bariloche and Instituto Balseiro, 8400 S.C. de Bariloche (RN) (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas (Argentina); Granada, J.R. [Comision Nacional de Energia Atomica, Centro Atomico Bariloche and Instituto Balseiro, 8400 S.C. de Bariloche (RN) (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas (Argentina)

    2010-08-15

    A general and systematic approach expressed in modern language, accounting for molecular motion effects on Doppler Broadening of Neutron Absorption Resonances (DBNAR) is given the form of a new model. It relies on well validated hypothesis: The separability of atomic from nuclear degrees of freedom, the use of the Van Hove scattering formalism and the fact that a conceptually identical approach produced experimentally proved predictions when applied to DBNAR in solid systems. We treat the molecular internal degrees of freedom approximately as harmonic oscillators. As a second contribution of this work, a synthetic model is presented in order to make the more complete model mentioned above suitable for neutron calculation codes. This second synthetic model reduces to the exact expressions of the complete model in the low and high neutron energy regimes and provides a plausible transition in between. Numerical results are presented for a general hypothetical case to show its strengths and limitations. Also, both models are applied to a real case of the {sup 238}U 6.674 eV resonant effective broadened absorption cross-section in UF6 (uranium hexafluoride). A direct experimental validation of our models is still necessary for which a special high resolution neutron transmission experiment ought to be devised at low temperatures and pressures on a gaseous system. It is showed how the synthetic model can be used to make thermometric predictions in an improved fashion in comparison to the effective temperature gas model at low temperatures.

  18. Doppler broadening and its contribution to Compton energy-absorption cross sections: An analysis of the Compton component in terms of mass-energy absorption coefficient

    International Nuclear Information System (INIS)

    Rao, D.V.; Takeda, T.; Itai, Y.; Akatsuka, T.; Cesareo, R.; Brunetti, A.; Gigante, G.E.

    2002-01-01

    Compton energy absorption cross sections are calculated using the formulas based on a relativistic impulse approximation to assess the contribution of Doppler broadening and to examine the Compton profile literature and explore what, if any, effect our knowledge of this line broadening has on the Compton component in terms of mass-energy absorption coefficient. Compton energy-absorption cross sections are evaluated for all elements, Z=1-100, and for photon energies 1 keV-100 MeV. Using these cross sections, the Compton component of the mass-energy absorption coefficient is derived in the energy region from 1 keV to 1 MeV for all the elements Z=1-100. The electron momentum prior to the scattering event should cause a Doppler broadening of the Compton line. The momentum resolution function is evaluated in terms of incident and scattered photon energy and scattering angle. The overall momentum resolution of each contribution is estimated for x-ray and γ-ray energies of experimental interest in the angular region 1 deg. -180 deg. . Also estimated is the Compton broadening using nonrelativistic formula in the angular region 1 deg. -180 deg., for 17.44, 22.1, 58.83, and 60 keV photons for a few elements (H, C, N, O, P, S, K, and Ca) of biological importance

  19. Doppler Broadening and its Contribution to Compton Energy-Absorption Cross Sections: An Analysis of the Compton Component in Terms of Mass-Energy Absorption Coefficient

    Science.gov (United States)

    Rao, D. V.; Takeda, T.; Itai, Y.; Akatsuka, T.; Cesareo, R.; Brunetti, A.; Gigante, G. E.

    2002-09-01

    Compton energy absorption cross sections are calculated using the formulas based on a relativistic impulse approximation to assess the contribution of Doppler broadening and to examine the Compton profile literature and explore what, if any, effect our knowledge of this line broadening has on the Compton component in terms of mass-energy absorption coefficient. Compton energy-absorption cross sections are evaluated for all elements, Z=1-100, and for photon energies 1 keV-100 MeV. Using these cross sections, the Compton component of the mass-energy absorption coefficient is derived in the energy region from 1 keV to 1 MeV for all the elements Z=1-100. The electron momentum prior to the scattering event should cause a Doppler broadening of the Compton line. The momentum resolution function is evaluated in terms of incident and scattered photon energy and scattering angle. The overall momentum resolution of each contribution is estimated for x-ray and γ-ray energies of experimental interest in the angular region 1°-180°. Also estimated is the Compton broadening using nonrelativistic formula in the angular region 1°-180°, for 17.44, 22.1, 58.83, and 60 keV photons for a few elements (H, C, N, O, P, S, K, and Ca) of biological importance.

  20. Using the Doppler broadened γ line of the {sup 10}B(n,αγ){sup 7}Li reaction for thermal neutron detection

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Galim, Y., E-mail: ybgx3@walla.com [Department of Nuclear Engineering, Ben Gurion University (BGU) of the Negev (Israel); Wengrowicz, U. [Department of Nuclear Engineering, Ben Gurion University (BGU) of the Negev (Israel); NRC-Negev, P.O. Box 9001, Beer-Sheva 84190 (Israel); Moreh, R. [Physics Department, Ben Gurion University (BGU) of the Negev, Beer-Sheva 84105 (Israel); Orion, I. [Department of Nuclear Engineering, Ben Gurion University (BGU) of the Negev (Israel); Raveh, A. [Advanced Coatings Center at Rotem Industries Ltd., MishorYamin D.N. Arava 86800 (Israel)

    2016-02-21

    When a thermal neutron is absorbed by {sup 10}B in the {sup 10}B(n,α){sup 7}Li reaction, there is a chance of 94% that a 478 keV photon be emitted by an excited {sup 7}Li nucleus. This reaction is exothermic with a Q-value of 2.31 MeV and the nuclei are emitted with kinetic energies of E(α)=1.47 MeV and E({sup 7}Li*)=0.84 MeV. This implies that the 478 keV γ line is emitted by a moving {sup 7}Li nucleus and hence is expected to be Doppler broadened. In the present work we suggest to use this broadening of the γ line as a fingerprint for the detection of thermal neutrons using a high resolution gamma spectrometer. We thus developed a Monte Carlo program using a MATLAB code based on a High Purity Germanium (HPGe) detector coupled with a Boron Carbide (B{sub 4}C) sheet to calculate the γ line broadening. Our simulation shows that the FWHM width of the resulting γ line is 12.6 keV, in good agreement with our measurement. Hence the broadened γ line emitted by the {sup 10}B(n,αγ){sup 7}Li reaction and detected by a HPGe detector shows that this method is an effective tool for neutron detection while maintaining good gamma discrimination. - Highlights: • Thermal neutron detection by measuring the Doppler broadened 478 keV γ line from the {sup 10}B(n,αγ){sup 7}Li interaction. • Natural Boron Carbide coupled with a HPGe detector were used in this study. • A mathematical Monte-Carlo model for the suggested detector was introduced. • A calibration tool for the suggested detector is introduced. • Experimental results show that the suggested method can be used for neutron detection.

  1. Kernel reconstruction methods for Doppler broadening — Temperature interpolation by linear combination of reference cross sections at optimally chosen temperatures

    International Nuclear Information System (INIS)

    Ducru, Pablo; Josey, Colin; Dibert, Karia; Sobes, Vladimir; Forget, Benoit; Smith, Kord

    2017-01-01

    This paper establishes a new family of methods to perform temperature interpolation of nuclear interactions cross sections, reaction rates, or cross sections times the energy. One of these quantities at temperature T is approximated as a linear combination of quantities at reference temperatures (T_j). The problem is formalized in a cross section independent fashion by considering the kernels of the different operators that convert cross section related quantities from a temperature T_0 to a higher temperature T — namely the Doppler broadening operation. Doppler broadening interpolation of nuclear cross sections is thus here performed by reconstructing the kernel of the operation at a given temperature T by means of linear combination of kernels at reference temperatures (T_j). The choice of the L_2 metric yields optimal linear interpolation coefficients in the form of the solutions of a linear algebraic system inversion. The optimization of the choice of reference temperatures (T_j) is then undertaken so as to best reconstruct, in the L∞ sense, the kernels over a given temperature range [T_m_i_n,T_m_a_x]. The performance of these kernel reconstruction methods is then assessed in light of previous temperature interpolation methods by testing them upon isotope "2"3"8U. Temperature-optimized free Doppler kernel reconstruction significantly outperforms all previous interpolation-based methods, achieving 0.1% relative error on temperature interpolation of "2"3"8U total cross section over the temperature range [300 K,3000 K] with only 9 reference temperatures.

  2. Techniques for obtaining velocity distributions of atoms or ions from Doppler-broadened spectral line profiles

    International Nuclear Information System (INIS)

    Moran, T.G.

    1986-12-01

    Analysis of the doppler-broadened profiles of spectral lines radiated by atoms or ions in plasmas yields information about their velocity distributions. Researchers have analysed profiles of lines radiated by atoms in isotropic velocity distributions in several ways, one being the inversion of the integral equation which relates the velocity distribution to the line profile. This inversion formula was derived for a separate application and was given to within an arbitrary multiplicative constant. This paper presents a new derivation which obtains the inversion exactly, using a method which is easily generalized for determination of anisotropic velocity distribution functions. The technique to obtain an anisotropic velocity distribution function from line profiles measured at different angles is outlined

  3. Electromagnetically-induced transparency in Doppler-broadened ...

    Indian Academy of Sciences (India)

    2014-02-08

    Feb 8, 2014 ... triple EIT windows depending on the amplitude and detuning of the coupling fields. Keywords. Electromagnetically-induced transparency; atomic ... photon transparency [6] and the effect of spontaneously generated coherence on EIT [7] using homogenously broadened models. Pramana – J. Phys., Vol.

  4. Low-temperature positron lifetime and Doppler-broadening measurements for single-crystal nickel oxide containing cation vacancies

    International Nuclear Information System (INIS)

    Waber, J.T.; Snead, C.L. Jr.; Lynn, K.G.

    1985-01-01

    Lifetime and Doppler-broadening measurements for positron annihilation in substoichiometric nickelous oxide have been made concomitantly from liquid-helium to room temperature. The concentration of cation vacancies is readily controlled by altering the ambient oxygen pressure while annealing the crystals at 1673 0 K. It was found that neither of the three lifetimes observed or their relative intensities varied significantly with the oxygen pressure, and the bulk rate only increased slightly when the specimen was cooled from room to liquid-helium temperatures. These results are interpreted as indicating that some of the positrons are trapped by the existing cation vacancies and a smaller fraction by vacancy clusters

  5. Mn doping in ZnO nanoparticles: effects investigated by positron lifetime and Doppler broadening studies

    Energy Technology Data Exchange (ETDEWEB)

    Roy, B.; Karmakar, B.; Pal, M. [Department of Physics, University of Burdwan, Golapbag, Burdwan (India); Nambissan, P.M.G. [Saha Institute of Nuclear Physics, Kolkata (India)

    2009-11-15

    Positron lifetime and Doppler broadening measurements in nanocrystalline zinc oxide (ZnO) indicated the negatively charged trivacancy-type defects V{sub Zn+O+Zn} as the predominant positron trapping sites within the nanocrystallites. They got converted to neutral divacancies (V{sub Zn+O}) on doping with manganese (Mn). Further doping resulted in the reduction of the size of the nanocrystallites. At still increased doping concentrations, a new phase ZnMn{sub 2}O{sub 4} was formed. It had a normal spinel structure with positron trapping centers at some of the tetrahedral and octahedral sites. X-ray diffraction and transmission electron micro-scopy studies confirmed these findings. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  6. EIT enhanced self-Kerr nonlinearity in the three-level lambda system under Doppler broadening

    International Nuclear Information System (INIS)

    Dinh Xuan Khoa; Le Van Doai; Pham Van Trong; Tran Manh Cuong; Vu Ngoc Sau; Nguyen Huy Bang; Le Nguyen Mai Anh

    2014-01-01

    Using density-matrix theory, an analytical expression of the self-Kerr nonlinear coefficient of a three-level lambda EIT medium for a weak probe light is derived. Influences of the coupling light and Doppler broadening on the self-Kerr coefficient are investigated and compared to experimental observation with a good agreement. The self-Kerr nonlinearity of the medium is modified and greatly enhanced in the spectral region of EIT window. Furthermore, sign, slope, and magnitude of the self-Kerr coefficient can be controlled with frequency and intensity of the coupling light and temperature of the medium. Specially, for a given set of fixed values of the parameters of coupling and probe lights, it could be able to choose an optimized temperature to have largest magnitude of the self-Kerr coefficient. Such controllable Kerr nonlinearity can find interesting applications in optoelectronic devices working with low-light intensity at various temperature conditions. (author)

  7. Deconvolution of shift-variant broadening for Compton scatter imaging

    International Nuclear Information System (INIS)

    Evans, Brian L.; Martin, Jeffrey B.; Roggemann, Michael C.

    1999-01-01

    A technique is presented for deconvolving shift-variant Doppler broadening of singly Compton scattered gamma rays from their recorded energy distribution. Doppler broadening is important in Compton scatter imaging techniques employing gamma rays with energies below roughly 100 keV. The deconvolution unfolds an approximation to the angular distribution of scattered photons from their recorded energy distribution in the presence of statistical noise and background counts. Two unfolding methods are presented, one based on a least-squares algorithm and one based on a maximum likelihood algorithm. Angular distributions unfolded from measurements made on small scattering targets show less evidence of Compton broadening. This deconvolution is shown to improve the quality of filtered backprojection images in multiplexed Compton scatter tomography. Improved sharpness and contrast are evident in the images constructed from unfolded signals

  8. Intensity dependence narrowing of electromagnetically induced absorption in a Doppler-broadened medium

    International Nuclear Information System (INIS)

    Dimitrijevic, J.; Arsenovic, D.; Jelenkovic, B. M.

    2007-01-01

    In this paper, we present a theoretical model for studying the interaction between linearly polarized laser light and near-degenerated Zeeman sublevels for a multiple V-type atomic system of 2 S 1/2 F g =2→ 2 P 3/2 F e =3 transition in 87 Rb. We have calculated the laser absorption in a Hanle configuration, as well as the amplitudes and the widths of electromagnetically induced absorption (EIA) in the range of laser intensities from 0.01 to 40 mW/cm 2 . Our results, showing nonvanishing EIA amplitude, a nonmonotonic increase of the EIA width for the increase of laser intensity, and pronounced shape differences of the Hanle EIA curves at different laser intensities, are in good agreement with recent experimental results. We have found that the EIA behaves differently than the electromagnetically induced transparency (EIT) as a function of the laser intensity. Both the amplitude and width of the EIA have narrow maximums at 1 to 2 mW/cm 2 . We have shown the strong influence of Doppler broadening of atomic transition on Hanle resonances and have suggested the explanation of it

  9. EIT enhanced self-Kerr nonlinearity in the three-level lambda system under Doppler broadening

    International Nuclear Information System (INIS)

    Doai, Le Van; Khoa, Dinh Xuan; Bang, Nguyen Huy

    2015-01-01

    Using density-matrix theory, an analytical expression of the self-Kerr nonlinear coefficient of a three-level lambda EIT medium for a weak probe light is derived. Influences of the coupling light and Doppler broadening on the self-Kerr coefficient are investigated and compared to experimental observation with a good agreement. The self-Kerr nonlinearity of the medium is modified and greatly enhanced in the spectral region of EIT window. Furthermore, sign, slope, and magnitude of the self-Kerr coefficient can be controlled with frequency and intensity of the coupling light and temperature of the medium. In particular, for a given set of fixed values of the parameter coupling and probe lights, it is possible to choose an optimized temperature with which to obtain the largest magnitude of the self-Kerr coefficient. Such a controllable Kerr nonlinearity can find interesting applications in optoelectronic devices working with low-light intensity at various temperature conditions. (paper)

  10. Digital setup for Doppler broadening spectroscopy

    International Nuclear Information System (INIS)

    Cizek, J; Vlcek, M; Prochazka, I

    2011-01-01

    New digital spectrometer for measurement of the Doppler shift of annihilation photons was developed and tested in this work. Digital spectrometer uses a fast 12-bit digitizer for direct sampling of signals from HPGe detectors. Analysis of sampled waveforms is performed off-line in software. Performance of the new digital setup was compared with its traditional analogue counterpart. Superior energy resolution was achieved in the digital setup. Moreover, the digital setup allows for a better control of the shape of detector signals. This enables to eliminate undesired signals damaged by pile-up effects or by ballistic deficit.

  11. Phonon characteristics of high Tc superconductors from neutron Doppler broadening measurements

    International Nuclear Information System (INIS)

    Trela, W.J.; Kwei, G.H.; Lynn, J.E.; Meggers, K.

    1994-01-01

    Statistical information on the phonon frequency spectrum of materials can be measured by neutron transmission techniques if they contain nuclei with low energy resonances, narrow enough to be Doppler-broadened, in their neutron cross sections. The authors have carried out some measurements using this technique for materials of the lanthanum barium cuprate class, La 2-x Ba x CuO 4 . Two samples with slightly different concentrations of oxygen, one being superconductive, the other not, were examined. Pure lanthanum cuprate was also measured. Lanthanum, barium and copper all have relatively low energy narrow resonances. Thus it should be possible to detect differences in the phonons carried by different kinds of atom in the lattice. Neutron cross section measurements have been made with high energy resolution and statistical precision on the 59m flight path of LANSCE, the pulsed spallation neutron source at Los Alamos National Laboratory. Measurements on all three materials were made over a range of temperatures from 15K to 300K, with small steps through the critical temperature region near 27K. No significant changes in the mean phonon energy of the lanthanum atoms were observed near the critical temperature of the super-conducting material. It appears however that the mean phonon energy of lanthanum in the superconductor is considerably higher than that in the non-superconductors. The samples used in this series of experiments were too thin in barium and copper to determine anything significant about their phonon spectra

  12. Phonon characteristics of high {Tc} superconductors from neutron Doppler broadening measurements

    Energy Technology Data Exchange (ETDEWEB)

    Trela, W.J.; Kwei, G.H.; Lynn, J.E. [Los Alamos National Lab., NM (United States); Meggers, K. [Univ. of Kiel (Germany)

    1994-12-01

    Statistical information on the phonon frequency spectrum of materials can be measured by neutron transmission techniques if they contain nuclei with low energy resonances, narrow enough to be Doppler-broadened, in their neutron cross sections. The authors have carried out some measurements using this technique for materials of the lanthanum barium cuprate class, La{sub 2{minus}x}Ba{sub x}CuO{sub 4}. Two samples with slightly different concentrations of oxygen, one being superconductive, the other not, were examined. Pure lanthanum cuprate was also measured. Lanthanum, barium and copper all have relatively low energy narrow resonances. Thus it should be possible to detect differences in the phonons carried by different kinds of atom in the lattice. Neutron cross section measurements have been made with high energy resolution and statistical precision on the 59m flight path of LANSCE, the pulsed spallation neutron source at Los Alamos National Laboratory. Measurements on all three materials were made over a range of temperatures from 15K to 300K, with small steps through the critical temperature region near 27K. No significant changes in the mean phonon energy of the lanthanum atoms were observed near the critical temperature of the super-conducting material. It appears however that the mean phonon energy of lanthanum in the superconductor is considerably higher than that in the non-superconductors. The samples used in this series of experiments were too thin in barium and copper to determine anything significant about their phonon spectra.

  13. Wall-collision line broadening of molecular oxygen within nanoporous materials

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Can T.; Lewander, Maerta; Andersson-Engels, Stefan; Svensson, Tomas; Svanberg, Sune [Department of Physics, Lund University, P. O. Box 118, SE-221 00 Lund (Sweden); Adolfsson, Erik [Ceramic Materials, SWEREA IVF, Box 104, SE-431 22 Moelndal (Sweden)

    2011-10-15

    Wall-collision broadening of near-infrared absorption lines of molecular oxygen confined in nanoporous zirconia is studied by employing high-resolution diode-laser spectroscopy. The broadening is studied for pores of different sizes under a range of pressures, providing new insights on how wall collisions and intermolecular collisions influence the total spectroscopic line profile. The pressure series show that wall-collision broadening is relatively more prominent under reduced pressures, enabling sensitive means to probe pore sizes of porous materials. In addition, we show that the total wall-collision-broadened profile strongly deviates from a Voigt profile and that wall-collision broadening exhibits an additive-like behavior to the pressure and Doppler broadening.

  14. High-resolution spectroscopy for Doppler-broadening ion temperature measurements of implosions at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Koch, J. A.; Stewart, R. E.; Beiersdorfer, P.; Shepherd, R.; Schneider, M. B.; Miles, A. R.; Scott, H. A.; Smalyuk, V. A.; Hsing, W. W. [Lawrence Livermore National Laboratory, P.O. Box 808, L-493, Livermore, California 94550 (United States)

    2012-10-15

    Future implosion experiments at the national ignition facility (NIF) will endeavor to simultaneously measure electron and ion temperatures with temporal and spatial resolution in order to explore non-equilibrium temperature distributions and their relaxation toward equilibrium. In anticipation of these experiments, and with understanding of the constraints of the NIF facility environment, we have explored the use of Doppler broadening of mid-Z dopant emission lines, such as krypton He-{alpha} at 13 keV, as a diagnostic of time- and potentially space-resolved ion temperature. We have investigated a number of options analytically and with numerical raytracing, and we have identified several promising candidate spectrometer designs that meet the expected requirements of spectral and temporal resolution and data signal-to-noise ratio for gas-filled exploding pusher implosions, while providing maximum flexibility for use on a variety of experiments that potentially include burning plasma.

  15. FPSPH DFPSPF, Line Shape Function for Doppler Broadened Resonance Cross-Sections Calculation

    International Nuclear Information System (INIS)

    Ribon, P.

    1982-01-01

    1 - Description of problem or function: In the computation of Doppler- broadened resonance cross sections, use is made of the symmetric and anti-symmetric line shape functions. These functions usually denoted as Psi and Phi (Psi and Chi in Anglo-Saxon formalism) are defined in terms of the real and imaginary parts of the error function for complex arguments. They are the product of the convolution of a Gaussian function with the symmetric and anti-symmetric Breit-Wigner functions, respectively. FPSPH and DFPSPH compute these functions. 2 - Method of solution: For (1+x 2 ) > 20 Beta 2 , the calculation is based upon the asymptotic expansion: Psi+(i*Phi) = 1/(1-ix)*(1-t+3t 2 -3.5t 3 +3.5+7t 4 ---), with: t = 1/(2z 2 ); z = (1-ix)/Beta. The half-plane (Beta,x) is split in several parts, and use is made of PADE approximants. For 1 + x 2 2 , the calculation is based upon the relation with the erf function: Psi + i*Phi = SQRT(Pi)/Beta*(e (z 2 ) )*(1-erf(z)) (z = (1-ix)/Beta, and erf(z) being calculated from its analytic expansion: erf(z) = 2/SQRT(Pi)*z*e (-z 2 ) *(1+z 2 /3+z 4 /(3*5) + z 6 /(3*5*7)+---). PADE approximants are used to compute the expansion and e z 2

  16. Applications of Doppler-free saturation spectroscopy for edge physics studies (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Martin, E. H., E-mail: martineh@ornl.gov; Caughman, J. B. O.; Isler, R. C.; Bell, G. L. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Zafar, A. [Department of Nuclear Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States)

    2016-11-15

    Doppler-free saturation spectroscopy provides a very powerful method to obtain detailed information about the electronic structure of the atom through measurement of the spectral line profile. This is achieved through a significant decrease in the Doppler broadening and essentially an elimination of the instrument broadening inherent to passive spectroscopic techniques. In this paper we present the technique and associated physics of Doppler-free saturation spectroscopy in addition to how one selects the appropriate transition. Simulations of H{sub δ} spectra are presented to illustrate the increased sensitivity to both electric field and electron density measurements.

  17. Verification of MC{sup 2}-3 Doppler Sample Models in ZPPR-15 D Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Jae; Hartanto, Donny; Kim, Sang Ji [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In this paper, the change of reaction rate and broadened cross section were estimated by as-built MCNP models for metallic uranium sample in ZPPR-15D using ENDF/B-VII.0 library, and the results were compared with deterministic calculations provided in previous work. The Doppler broadening is an instant feedback mechanism that improves safety and stability for both thermal and fast reactors. Therefore, the accuracy of Doppler coefficient becomes an important parameter in reactor design as well as in the safety analysis. The capability of the Doppler worth calculation by a modern computer code suites such as MC2-3 and DIF3DVARIANT, has been validated against the Zero Power Physics Reactor-15 (ZPPR-15) Doppler worth measurement experiments. For the same experiments, our previous work suggested four different MC2-3 Doppler sample models for enhanced accuracy, which are combinations of heterogeneous models and the super cell approach. The MOC and MOC-SPC models showed the smallest error in estimating the U-238 total cross section of Doppler sample N-11, and the Doppler broadening effects are well applied to the cross section compared to other two models, HOM and SPC. The effects of the super cell approach can be hardly seen, since the broadened cross section is almost the same with and without the super cell approach. Comparing the transition of reaction density, MOC and MOC-SPC models also show similar behavior as MCNP's with minor errors. As a conclusion, we could obtain more consistent broadened cross section as well as reaction density transition by providing heterogeneous models from MC2-3's MOC module.

  18. Doppler Broadening Analysis of Steel Specimens Using Accelerator Based In Situ Pair Production

    International Nuclear Information System (INIS)

    Makarashvili, V.; Wells, D. P.; Roy, A. K.

    2009-01-01

    Positron Annihilation Spectroscopy (PAS) techniques can be utilized as a sensitive probe of defects in materials. Studying these microscopic defects is very important for a number of industries in order to predict material failure or structural integrity. We have been developing gamma-induced pair-production techniques to produce positrons in thick samples (∼4-40 g/cm 2 , or ∼0.5-5 cm in steel). These techniques are called 'Accelerator-based Gamma-induced Positron Annihilation Spectroscopy'(AG-PAS). We have begun testing the capabilities of this technique for imaging of defect densities in thick structural materials. As a first step, a linear accelerator (LINAC) was employed to produce photon beams by stopping 15 MeV electrons in a 1 mm thick tungsten converter. The accelerator is capable of operating with 30-60 ns pulse width, up to 200 mA peak current at 1 kHz repetition rate. The highly collimated bremsstrahlung beam impinged upon our steel tensile specimens, after traveling through a 1.2 m thick concrete wall. Annihilation radiation was detected by a well-shielded and collimated high-purity germanium detector (HPGe). Conventional Doppler broadening spectrometry (DBS) was performed to determine S, W and T parameters for our samples.

  19. Helium implanted Eurofer97 characterized by positron beam Doppler broadening and Thermal Desorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, I., E-mail: i.carvalho@m2i.nl [Materials Innovation Institute (M2i), Delft (Netherlands); Schut, H. [Delft University of Technology, Faculty of Applied Sciences, Delft (Netherlands); Fedorov, A.; Luzginova, N. [Nuclear Research and Consultancy Group (NRG), Petten (Netherlands); Desgardin, P. [CEMHTI-CNRS, 3A Rue de la Férolerie, 45071 Orléans Cedex (France); Sietsma, J. [Delft University of Technology, Faculty of Mechanical, Maritime and Materials Engineering, Delft (Netherlands)

    2013-11-15

    Reduced Activation Ferritic/Martensitic steels are being extensively studied because of their foreseen application in fusion and Generation IV fission reactors. To produce irradiation induced defects, Eurofer97 samples were implanted with helium at energies of 500 keV and 2 MeV and doses of 1 × 10{sup 15}–10{sup 16} He/cm{sup 2}, creating atomic displacements in the range 0.07–0.08 dpa. The implantation induced defects were characterized by positron beam Doppler Broadening (DB) and Thermal Desorption Spectroscopy (TDS). Results show that up to ∼600 K peaks that can be attributed to He desorption from overpressured He{sub n}V{sub m} (n > m) clusters and vacancy assisted mechanism in the case of helium in the substitutional position. The temperature range 600–1200 K is related to the formation of larger clusters He{sub n}V{sub m} (n < m). The dissociation of the HeV and the phase transition attributed to a sharp peak in the TDS spectra at 1200 K. Above this temperature, the release of helium from bubbles is observed.

  20. Application of Positron Doppler Broadening Spectroscopy to the Measurement of the Uniformity of Composite Materials

    International Nuclear Information System (INIS)

    Quarles, C. A.; Sheffield, Thomas; Stacy, Scott; Yang, Chun

    2009-01-01

    The uniformity of rubber-carbon black composite materials has been investigated with positron Doppler Broadening Spectroscopy (DBS). The number of grams of carbon black (CB) mixed into one hundred grams of rubber, phr, is used to characterize a sample. A typical concentration for rubber in tires is 50 phr. The S parameter measured by DBS has been found to depend on the phr of the sample as well as the type of rubber and carbon black. The variation in carbon black concentration within a surface area of about 5 mm diameter can be measured by moving a standard Na-22 or Ge-68 positron source over an extended sample. The precision of the concentration measurement depends on the dwell time at a point on the sample. The time required to determine uniformity over an extended sample can be reduced by running with much higher counting rate than is typical in DBS and correcting for the systematic variation of S parameter with counting rate. Variation in CB concentration with mixing time at the level of about 0.5% has been observed.

  1. Importance of Doppler broadening in Compton scatter imaging techniques

    Science.gov (United States)

    Rao, Donepudi V.; Takeda, Tohoru; Itai, Yuji; Seltzer, S. M.; Hubbell, John H.; Zeniya, Tsutomu; Akatsuka, Takao; Cesareo, Roberto; Brunetti, Antonio; Gigante, Giovanni E.

    2001-12-01

    Compton scattering is a potential tool for the determination of bone mineral content or tissue density for dose planning purposes, and requires knowledge of the energy distribution of the X-rays through biological materials of medical interest in the X-ray and (gamma) -ray region. The energy distribution is utilized in a number of ways in diagnostic radiology, for example, in determining primary photon spectra, electron densities in separate volumes, and in tomography and imaging. The choice of the X-ray energy is more related to X-ray absorption, where as that of the scattering angle is more related to geometry. The evaluation of all the contributions are mandatory in Compton profile measurements and is important in X-ray imaging systems in order to achieve good results. In view of this, Compton profile cross-sections for few biological materials are estimated at nineteen K(alpha) X-ray energies and 60 keV (Am-241) photons. Energy broadening, geometrical broadening from 1 to 180 degree(s), FWHM of J(Pz) and FWHM of Compton energy broadening has been evaluated at various incident photon energies. These values are estimated around the centroid of the Compton profile with an energy interval of 0.1 keV and 1.0 keV for 60 keV photons. The interaction cross sections for the above materials are estimated using fractions-by-weight of the constituent elements. Input data for these tables are purely theoretical.

  2. Laser methods of. gamma. spectroscopy without Doppler broadening

    Energy Technology Data Exchange (ETDEWEB)

    Letokhov, V S [AN SSSR, Moscow. Inst. Spektroskopii

    1976-01-01

    Some new ideas and methods being conceived in a boundary area between atomic-molecular and nuclear physics are discussed. The recent progress with lasers tunable in the UV, visible, and IR should make the realization of these methods quite possible. There are at least two effects that link atomic and molecular transitions with nuclear transitions: they are the recoil effect and the Doppler effect.

  3. The Doppler paradigm and the APEX-EPOS-ORANGE quandary

    International Nuclear Information System (INIS)

    Griffin, J.J.

    1995-01-01

    The experimental detection of the sharp lines of the (e + e - ) Puzzle is viewed as a struggle against Doppler broadening. Gedanken experiments which are realistic in zeroth order of detail are analyzed to show that the ORANGE and EPOS/I geometries select narrower slices of a Doppler broadened line than spherically inclusive (APEX and EPOS/II -like) apparati. Roughly speaking, the latter require event-by-event Doppler reconstruction simply to regain an even footing with the former. This suggests that APEX' or EPOS/II's coincident pair distributions must be statistically superior to those of EPOS/I or ORANGE in order to support a comparable inference about sharp structure. Under such circumstances, independent alternative data is invaluable. Therefore, a corroboration of Sakai's 330.1 keV ( + or e - bombardments of U and Th targets could prove crucial

  4. Electron irradiation effect of polyurethane using coincidence doppler-broadening spectroscopy

    International Nuclear Information System (INIS)

    Yang, D.J.; Zhang, J.D.; Leung, J.K.C.; Beling, C.D.; Liu, L.B.

    2006-01-01

    Full text: To understand the electron irradiation effects on polymer, polyether-urethane (ETPU) samples of 2m m in thickness and 1 0 m m in diameter were irradiated by a 1.8M eV electron beam with beam current of 3 ma at room temperature. The irradiated doses are 5 kGy, 10 kGy, 15 kGy, 30 kGy, 100 kGy and 150 kGy. ETPU was manufactured by mixing PTMG-100, TDI-100 and MOCA. The momentum density distributions (MMDs) of electrons taking part in the annihilation processes of positron-electron pairs in ETPU have been measured by coincidence Doppler-broadening spectroscopy (CDBS). By presenting the ratio of the counts in every channel of the measured CDB spectrum to the corresponding counts from a reference spectrum (pristine ETPU), we observed that the change in MMDs is not significant for doses lower than 10 kGy. However, high momentum part of MMDs exhibit an obvious decrease for dose exceeding 15 kGy and then slowly down to steady with doses until 150 kGy. This valley occurs at around 15 x1 0 3m οc and is well known as oxygen-specific, indicative of a less positron trapping by oxygen atoms in some samples of higher dose radiation. It is postulated that the radiation will break the crosslinkings, allowing the trace water and oxygen molecules to be released from the sample surface. Excess NCO groups in ETPU would crosslink with urethane and urea groups to produce allophanate and biuret groups. After receiving a certain amount of electron irradiation, crosslinked allophanate and biuret groups would produce degradation. Thus, residual water and oxygen trapped in ETPU by the crosslinking would diffuse out. However, the irradiation doses up to 150 kGy in this experiment are still not large enough to induce strong degradation of urethane and urea groups

  5. Coincidence Doppler broadening and 3DAP study of the pre-precipitation stage of an Al-Li-Cu-Mg-Ag alloy

    International Nuclear Information System (INIS)

    Honma, T.; Yanagita, S.; Hono, K.; Nagai, Y.; Hasegawa, M.

    2004-01-01

    Pre-precipitation solute clustering in Al-Li-Cu-Mg-Ag and Al-Cu-Mg-Ag alloys has been investigated by coincidence Doppler broadening (CDB) spectroscopy of positron annihilation and three-dimensional atom probe (3DAP) analysis. Although Ag-Mg co-clusters form in the Al-Cu-Mg-Ag alloy in the early stage of aging, no evidence for the co-cluster formation was obtained from the Li containing alloy using 3DAP. While CDB spectra indicated that vacancies are associated with Ag after aging for 15 s in the Al-Cu-Mg-Ag alloy, vacancy-Ag association is suppressed in the Li containing alloy. Based on the 3DAP and CDB results, the reasons for the completely different clustering behaviors observed in these two similar alloys are discussed

  6. Integrated system for production of neutronics and photonics calculational constants. Program SIGMA1 (Version 77-1): Doppler broaden evaluated cross sections in the Evaluated Nuclear Data File/Version B (ENDF/B) format

    International Nuclear Information System (INIS)

    Cullen, D.E.

    1977-01-01

    A code, SIGMA1, has been designed to Doppler broaden evaluated cross sections in the ENDF/B format. The code can only be applied to tabulated data that vary linearly in energy and cross section between tabulated points. This report describes the methods used in the code and serves as a user's guide to the code

  7. Helium implanted RAFM steels studied by positron beam Doppler Broadening and Thermal Desorption Spectroscopy

    International Nuclear Information System (INIS)

    Carvalho, I; Schut, H; Fedorov, A; Luzginova, N; Desgardin, P; Sietsma, J

    2013-01-01

    Reduced Activation Ferritic/Martensitic steels are being extensively studied because of their foreseen application in fusion and Generation IV fission reactors. To mimic neutron irradiation conditions, Eurofer97 samples were implanted with helium ions at energies of 500 keV and 2 MeV and doses of 5x10 15 -10 16 He /cm 2 , creating atomic displacements in the range 0.07–0.08 dpa. The implantation induced defects were characterized by positron beam Doppler Broadening (DB) and Thermal Desorption Spectroscopy (TDS). The DB data could be fitted with one or two layers of material, depending on the He implantation energy. The S and W values obtained for the implanted regions suggest the presence of not only vacancy clusters but also positron traps of the type present in a sub-surface region found on the reference sample. The traps found in the implanted layers are expected to be He n V m clusters. For the 2 MeV, 10 16 He/cm 2 implanted sample, three temperature regions can be observed in the TDS data. Peaks below 450 K can be ascribed to He released from vacancies in the neighbourhood of the surface, the phase transition is found at 1180 K and the peak at 1350 K is likely caused by the migration of bubbles.

  8. Stark broadening in hot, dense laser-produced plasmas

    International Nuclear Information System (INIS)

    Tighe, R.J.; Hooper, C.F. Jr.

    1976-01-01

    Broadened Lyman-α x-ray lines from neon X and argon XVIII radiators, which are immersed in a hot, dense deuterium or deuterium-tritium plasma, are discussed. In particular, these lines are analyzed for several temperature-density cases, characteristic of laser-produced plasmas; special attention paid to the relative importance of ion, electron, and Doppler effects. Static ion microfield distribution functions are tabulated

  9. Integrated system for production of neutronics and photonics calculational constants. Volume 17, Part B, Rev. 1. Program SIGMA 1 (Version 78-1): Doppler broadened evaluated cross sections in the evaluated nuclear data file/Version B (ENDF/B) format

    International Nuclear Information System (INIS)

    Cullen, D.E.

    1978-01-01

    The code SIGMA1 Doppler broadens evaluated cross sections in the ENDF/B format. The code can be applied only to data that vary as a linear function of energy and cross section between tabulated points. This report describes the methods used in the code and serves as a user's guide to the code. 6 figures, 2 tables

  10. Inline Ultrasonic Rheometry by Pulsed Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Pfund, David M.; Greenwood, Margaret S.; Bamberger, Judith A.; Pappas, Richard A.

    2006-12-22

    This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined by using a pulsed ultrasonic Doppler velocimeter. This approach is ideal for making non-invasive, real-time measurements for monitoring and control. Rheograms of a shear thinning, thixotropic gel will be presented. The operating parameters and limitations of the Doppler-based instrument will be discussed. The most significant limitation is velocity gradient broadening of the Doppler spectra near the walls of the pipe. This limitation can be significant for strongly shear thinning fluids (depending also on the ratio of beam to pipe diameter and the transducer's insertion angle).

  11. Maximisation of the Doppler effect in thermal reactors

    International Nuclear Information System (INIS)

    Bende, E.E.

    1998-03-01

    Increase of the fuel temperature in a nuclear reactor leads, or can lead, to (1) A Doppler broadening of the resonances of the nuclides in the fuel; (2) An expansion of the fuel; and (3) A shift of the Maxwellian part of the spectrum to higher energies. These processes together introduce a certain amount of reactivity, which can be expressed in the so-called fuel temperature reactivity coefficient. The reactivity effect of the third process is very small, because the Maxwell spectrum is to a major extent determined by the moderator temperature. Moreover, the reactivity effect due to an expansion of the fuel is small too, for most thermal systems. When the second and third processes can be neglected, the fuel temperature reactivity effect is fully determined by the Doppler effect. The fuel temperature reactivity coefficient is then called the Doppler coefficient of reactivity. The Doppler broadening of the resonances causes an increase of resonance absorption, due to a decrease of self-shielding. The competition between resonance fission at the one hand and resonance capture at the other hand determines the sign and magnitude of the reactivity induced by an increase of the fuel temperature. In well-designed nuclear reactors the Doppler effect due to resonance capture by fertile nuclides exceeds the Doppler effect due to resonance fission, which implies that an increase of the fuel temperature causes a negative reactivity effect and a correspondingly negative Doppler coefficient. Since the Doppler effect is a prompt effect, occurring simultaneously with the dissipation of kinetic energy of the fission products into temperature, it is very important in the study of rapid power transients. In this report, the Doppler coefficient of reactivity is defined in chapter 2. Chapter 3 discusses the geometry of the unit-cell for which the calculations are performed and describes the fuel types that have been investigated. In chapter 4 the 'Doppler efficiency' is introduced and

  12. Foreign gas pressure broadening and shifts of the 2S-4S two-photon transition in lithium

    International Nuclear Information System (INIS)

    DeGraffenreid, W; Campbell, Sarah C; Sansonetti, Craig J

    2003-01-01

    We have observed broadening and shift of the 2S-4S Doppler-free two-photon transition of atomic Li by collisions with neon and argon buffer gases in a heat-pipe oven. Measured broadening and shift rates are presented and compared with theoretical predictions calculated in the impact approximation using three different interaction potentials. A superposition of polarization and modified Fermi potentials gives good agreement with the experimental data

  13. Method and system to measure temperature of gases using coherent anti-stokes doppler spectroscopy

    Science.gov (United States)

    Rhodes, Mark

    2013-12-17

    A method of measuring a temperature of a noble gas in a chamber includes providing the noble gas in the chamber. The noble gas is characterized by a pressure and a temperature. The method also includes directing a first laser beam into the chamber and directing a second laser beam into the chamber. The first laser beam is characterized by a first frequency and the second laser beam is characterized by a second frequency. The method further includes converting at least a portion of the first laser beam and the second laser beam into a coherent anti-Stokes beam, measuring a Doppler broadening of the coherent anti-Stokes beam, and computing the temperature using the Doppler broadening.

  14. A comparison of the doppler-broadened positron annihilation spectra of neutron irradiated Al 2O 3 and MgAl 2O 3

    Science.gov (United States)

    Jones, P. L.; Schaffer, J. P.; Cocks, F. H.; Clinard, F. W.; Hurley, G. F.

    1985-01-01

    Radiation damage studies of oxides and ceramics have become of increasing importance due to the projected use of these materials in thermonuclear fusion reactors as electronic insulators and first wall materials. In addition these materials are important in RAD waste disposal. As part of a study of the defect structure in radiation damaged ceramics Doppler-broadened positron annihilation spectra have been obtained for a series of single crystal sapphire (α-Al 2O 3) and polycrystal (1:1) and (1:2) magnesium aluminate spinel (MgO·Al 2O 3 and MgO-2Al 2O 3) samples. These samples were irradiated in EBR-II to a fluence of 3 × 10 25 n/m 2 (E > 0.1 MeV) at 740°C, and 2 × 10 26 n/m 2 (E > 0.1 MeV) at ~ 550°C respectively. Positron annihilation spectra lineshapes for the irradiated, annealed, and as-received samples of both materials were compared using S parameter analysis. These calculations were made on deconvoluted gamma ray spectra that were free of any instrumental broadening effects. In this way, absolute S parameter changes could be calculated. The observed changes in the S parameter are consistent with independent volume swelling measurements for both the α-A1 2O 3 and the (1:2) MgAl 2O 4 samples. However, the change in S parameter measured for the (1:1) spinel is contrary to the measured volume change. This apparent anomaly indicates a predominence of interstitial as opposed to vacancy type defects in this material.

  15. Integrated system for production of neutronics and photonics calculational constants. Volume 17, Part B, Rev. 1. Program SIGMA 1 (Version 78-1): Doppler broadened evaluated cross sections in the evaluated nuclear data file/Version B (ENDF/B) format. [For CDC-7600

    Energy Technology Data Exchange (ETDEWEB)

    Cullen, D.E.

    1978-07-04

    The code SIGMA1 Doppler broadens evaluated cross sections in the ENDF/B format. The code can be applied only to data that vary as a linear function of energy and cross section between tabulated points. This report describes the methods used in the code and serves as a user's guide to the code. 6 figures, 2 tables.

  16. Spectral broadening of VLF transmitter signals and sideband structure observed on Aureol 3 satellite at middle latitudes

    International Nuclear Information System (INIS)

    Tanaka, Y.; Hayakawa, M.; Lagoutte, D.; Lefeuvre, F.; Tajima, S.

    1987-01-01

    Electric and magnetic field wave data acquired on Aureol 3 satellite demonstrate the existence of a spectral broadening effect in which VLF transmitter signals from Alpha station (geographic coordinates, 50.5 degree N, 137 degree E) in USSR undergo a significant spectral broadening on electric fields as they propagate through the ionosphere up to the spacecraft in the altitude range of 500-2,000 km at middle latitudes (L ∼ 2). The spectral broadening phenomena may be divided into two types: (1) spectrally broadened components occurring without any association with ELF/VLF emissions under disturbed ionospheric conditions and (2) spectrally broadened components with predominant sideband structure in association with ELF emissions. Bicoherence computation results suggest a nonlinear mode coupling between the transmitter signal and ELF emission which produces sidebands that are quasi-electrostatic in nature. However, faint spectral broadened components in both types 1 and 2 may be connected with Doppler shift of quasi-electrostatic whistler mode waves with a broad spectrum of k near the resonance cone, due to scattering of the transmitter signals from ionospheric irregularities in the F region

  17. H{sub {beta}} Stark broadening in cold plasmas with low electron densities calibrated with Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Palomares, J.M., E-mail: j.m.palomares-linares@tue.nl [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Huebner, S.; Carbone, E.A.D.; Vries, N. de; Veldhuizen, E.M. de [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Sola, A.; Gamero, A. [Departamento de Fisica, Universidad de Cordoba, Campus de Rabanales, ed. C-2, 14071 Cordoba (Spain); Mullen, J.J.A.M. van der [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands)

    2012-07-15

    In the present work Stark broadening measurements have been carried out on low electron density (n{sub e} < 5{center_dot}10{sup 19} m{sup -3}) and (relatively) low gas temperature (T{sub g} < 1100 K) argon-hydrogen plasma, under low-intermediate pressure conditions (3 mbar-40 mbar). A line fitting procedure is used to separate the effects of the different broadening mechanisms (e.g. Doppler and instrumental broadening) from the Stark broadening. A Stark broadening theory is extrapolated to lower electron density values, below its theoretical validity regime. Thomson scattering measurements are used to calibrate and validate the procedure. The results show an agreement within 20%, what validates the use of this Stark broadening method under such low density conditions. It is also found that Stark broadened profiles cannot be assumed to be purely Lorentzian. Such an assumption would lead to an underestimation of the electron density. This implies that independent information on the gas temperature is needed to find the correct values of n{sub e}. - Highlights: Black-Right-Pointing-Pointer Stark broadening measurements at low density and temperature conditions Black-Right-Pointing-Pointer Calibration with Thomson scattering Black-Right-Pointing-Pointer Indications of the non-Lorentzian shape of the Stark broadening Black-Right-Pointing-Pointer Impossibility of simultaneous diagnostic of gas temperature and electron density.

  18. Temperature dependence of the hydrogen-broadening coefficient for the nu 9 fundamental of ethane

    Science.gov (United States)

    Halsey, G. W.; Hillman, J. J.; Nadler, Shacher; Jennings, D. E.

    1988-01-01

    Experimental results for the temperature dependence of the H2-broadening coefficient for the nu 9 fundamental of ethane are reported. Measurements were made over the temperature range 95-300 K using a novel low-temperature absorption cell. These spectra were recorded with the Doppler-limited diode laser spectrometer at NASA Goddard. The results are compared with recent measurements and model predictions.

  19. Anomalous broadening of the N2+ first negative band system

    International Nuclear Information System (INIS)

    Robben, F.; Cattolica, R.; Coe, D.; Talbot, L.

    1976-01-01

    Analysis of the fluorescence excited by a high energy electron beam has become a standard technique for measurement of density, rotational temperature of nitrogen, and translational temperature of helium and argon in rarefied gas dynamics. To obtain translational temperature the Doppler broadening of the fluorescence is determined by measuring the spectral line shape with a Fabry-Perot interferometer. To apply this technique to nitrogen a single rotational line must be selected from the band spectrum for analysis by the Fabry-Perot interferometer. As supported by extensive additional measurements, there is an anomalous broadening of the rotational lines of the N 2 + first negative band system with a width equivalent to about a 70 0 K translational temperature of nitrogen. It appears that the line width of approximately 0.03 cm -1 is an inherent property of this nitrogen band when excited by electron impact directly from the ground state

  20. Development of Rayleigh Doppler lidar for measuring middle atmosphere winds

    Science.gov (United States)

    Raghunath, K.; Patra, A. K.; Narayana Rao, D.

    Interpretation of most of the middle and upper atmospheric dynamical and chemical data relies on the climatological description of the wind field Rayleigh Doppler lidar is one instrument which monitors wind profiles continuously though continuity is limited to clear meteorological conditions in the middle atmosphere A Doppler wind lidar operating in incoherent mode gives excellent wind and temperature information at these altitudes with necessary spectral sensitivity It observes atmospheric winds by measuring the spectral shift of the scattered light due to the motions of atmospheric molecules with background winds and temperature by spectral broadening The presentation is about the design and development of Incoherent Doppler lidar to obtain wind information in the height regions of 30-65 km The paper analyses and describes various types of techniques that can be adopted viz Edge technique and Fringe Imaging technique The paper brings out the scientific objectives configuration simulations error sources and technical challenges involved in the development of Rayleigh Doppler lidar The presentation also gives a novel technique for calibrating the lidar

  1. Influence of Doppler and 'Stark' effects on the shape of the autoionization peaks in electron energy spectra produced in ion-atom collisions

    International Nuclear Information System (INIS)

    Gleizes, A.; Benoit-Cattin, P.; Bordenave-Montesquieu, A.; Merchez, H.

    1976-01-01

    A detailed study is given of the influence of the Doppler shift and broadening on the spectra of electrons ejected by autoionization in collisions between heavy particles. General formulae have been obtained which permit the validity of results already published by other authors to be discussed. These results have been applied to the spectra of electrons ejected in He + -He collisions at 15 keV. The variation of the width of the autoionization peaks against ejection angle is well explained by Doppler broadening. On the contrary, the shape of these peaks cannot be due to the Doppler effect but rather to the Stark effect which is also studied in various experimental cases; it has been verified that the latter effect disappears in collisions between neutral particles for which symmetric peaks at 15 keV are obtained. (author)

  2. 3D atom microscopy in the presence of Doppler shift

    Science.gov (United States)

    Rahmatullah; Chuang, You-Lin; Lee, Ray-Kuang; Qamar, Sajid

    2018-03-01

    The interaction of hot atoms with laser fields produces a Doppler shift, which can severely affect the precise spatial measurement of an atom. We suggest an experimentally realizable scheme to address this issue in the three-dimensional position measurement of a single atom in vapors of rubidium atoms. A three-level Λ-type atom-field configuration is considered where a moving atom interacts with three orthogonal standing-wave laser fields and spatial information of the atom in 3D space is obtained via an upper-level population using a weak probe laser field. The atom moves with velocity v along the probe laser field, and due to the Doppler broadening the precision of the spatial information deteriorates significantly. It is found that via a microwave field, precision in the position measurement of a single hot rubidium atom can be attained, overcoming the limitation posed by the Doppler shift.

  3. The scavenging of the precursors of the solvated electrons fom the positron lifetime spectroscopy and the Doppler broadening of annihilation line shape technique

    International Nuclear Information System (INIS)

    Abbe, J.C.; Duplatre, G.; Maddock, A.G.; Haessler, A.

    1979-01-01

    The electron scavenging properties in water of two series of solutes are investigated, using the positron as a probe. For a better interpretation of the data, both the lifetime specroscopy and the Doppler broadening of annihilation line shape technique are used. All solutes inhibit the positronium (Ps) formation, by the scavenging of electron. The first series consists of the halate ions, that should follow the Hunt linear relation between the rate constant for reaction with the solvated electrons, ksub(e - sub(aq)+S) and that for its precursors(s), 1/C 37 . The Ps inhibition constants, k, are 0.14, 1.44 and 3.45M -1 for ClO 3 - , BrO 3 - and IO 3 - respectively. This sequence is quantitatively consistent with that of the respective ksub(e - sub(aq)+S). The second series includes the SeO 4 -- , Te(OH) 6 and BrO 4 - species, and the Ps inhibition constants are 5.62, 10.5 and 14.3 respectively. Theses values are much higher than expected from the ksub(e - sub(aq)+S) constants, on basis of the Hunt relation, in agreement with previous results from pulse radiolysis experiments

  4. Reply to "Comment on `Dynamics of slow light and light storage in a Doppler-broadened electromagnetically-induced-transparency medium: A numerical approach' "

    Science.gov (United States)

    Gou, Shih-Chuan; Su, Shih-Wei; Yu, Ite A.

    2017-10-01

    A damping term in the theoretical model of our paper [Phys. Rev. A 83, 013827 (2011), 10.1103/PhysRevA.83.013827] was questioned by the author of the Comment. The author argued this damping term cannot exactly describe the spontaneous decay or quantum jump process and, thus, concluded that our results are prone to be incorrect. However, the physics of electromagnetically induced transparency (EIT) is mainly determined by the ground-state coherence and the optical coherence of the probe transition. We show here that the damping term in our paper described the relaxation process of optical coherence in the EIT system, but not the spontaneous decay process of the population. The case of spontaneous decay used in the argument of the Comment is not an issue in typical EIT studies, in which the probe field is weak and treated as the perturbation. Furthermore, the experimental data in the paper were taken under the condition of a weak probe field. Our theoretical model in the weak-probe condition actually deals with the two coherences of EIT physics, and is suitable for analysis of the data. We believe the results of the study, focusing on the dynamics of slow light and light storage in Doppler-broadened EIT media, are correct.

  5. Correction of Doppler broadening of {gamma}-ray lines induced by particle emission in heavy-ion induced fusion-evaporation reactions

    Energy Technology Data Exchange (ETDEWEB)

    Nyberg, J; Seweryniak, D; Fahlander, C; Insua-Cao, P [Uppsala Univ. (Sweden). Dept. of Radiation Sciences; Johnson, A; Cederwall, B [Manne Siegbahn Inst. of Physics, Stockholm (Sweden); [Royal Inst. of Tech., Stockholm (Sweden); Adamides, E; Piiparinen, M [National Centre for Scientific Research, Ag. Paraskevi, Attiki (Greece); Atac, A; Norlin, L O [Niels Bohr Inst., Copenhagen (Denmark); Ideguchi, E; Mitarai, S [Kyushu Univ., Fukuoka (Japan). Dept. of Physics; Julin, R; Juutinen, S; Tormanen, S; Virtanen, A [Jyvaeskylae Univ. (Finland). Dept. of Physics; Karczmarczyk, W; Kownacki, J [Warsaw Univ. (Poland); Schubart, R [Hahn-Meitner-Institut Berlin GmbH (Germany)

    1992-08-01

    The effect of particle emission on the peak shape of {gamma}-ray lines have been investigated using the NORDBALL detector system. By detecting neutrons, protons and {alpha} particles emitted in the {sup 32}S (95 MeV) + {sup 27}Al reaction, the energy and direction of emission of the residual nuclei could be determined and subsequently used for an event-by -event Doppler correction of the detected {gamma} rays. Extensive Monte Carlo simulations were performed to study how the different Doppler phenomena influence the peak shape and in particular which particle detector properties are important for the Doppler correction. (author). 2 refs., 1 tab., 4 figs.

  6. Broadening of hydrogenic X rays emitted by a laser-produced plasma

    International Nuclear Information System (INIS)

    Nguyen, Hoe; Grumberg, J.; Caby, M.; Leboucher, E.; Coulaud, G.

    1980-01-01

    This study is devoted to X-rays broadened by laser impact or implosion. In addition to usual broadening processes due to the high and low components of plasma microfield, we have examined the influence of the self-generated magnetic field B which is correlated to the Doppler effect by the motional electric field. Concerning the interaction between plasma electrons and radiating ions with high charge number Zsub(E), it is shown that the curvature of electron trajectories must be taken into account in the broadening operator calculation. The influence of this curvature consists in reducing the contribution of dipolar interaction and enhancing the contribution of multipolar interactions with higher order. As a particular consequence on the half-width of Lyman-α-lines we have found values ten times larger than those obtained from the usual dipolar approximation. In the other hand, spectral lines emitted from the plasma critical region exhibits a strong self-generated magnetic field effect. Principally, it consists in polarizing the spectral profiles and introducing a large dependence with respect to the observation direction k. Particularly, profiles observed in the direction parallel to the magnetic field exhibit a deep central minimum which must be taken into account in a quantitative study of the line absorption properties [fr

  7. Nonlinear narrow Doppler-free resonances for optical transitions and annihilation radiation of a positronium atom

    International Nuclear Information System (INIS)

    Letokhov, V.S.; Minogin, V.G.

    1976-01-01

    The possibilities of obtaining narrow resonances without the Doppler broadening for transition between the fine structure levels of the ground and first excited states of a positronium atom are considered. An analysis is carried out of the conditions required for observation of the narrow resonances of saturation of single quantum absorption in the 1S-2P transitions and observation of narrow two-photon absorption resonances in the 1S-2S transitions. It is shown that narrow 2γ annihilation radiation lines of a positronium atom may be obtained with a width much smaller than the Doppler one

  8. Deconvoluting double Doppler spectra

    International Nuclear Information System (INIS)

    Ho, K.F.; Beling, C.D.; Fung, S.; Chan, K.L.; Tang, H.W.

    2001-01-01

    The successful deconvolution of data from double Doppler broadening of annihilation radiation (D-DBAR) spectroscopy is a promising area of endeavour aimed at producing momentum distributions of a quality comparable to those of the angular correlation technique. The deconvolution procedure we test in the present study is the constrained generalized least square method. Trials with computer simulated DDBAR spectra are generated and deconvoluted in order to find the best form of regularizer and the regularization parameter. For these trials the Neumann (reflective) boundary condition is used to give a single matrix operation in Fourier space. Experimental D-DBAR spectra are also subject to the same type of deconvolution after having carried out a background subtraction and using a symmetrize resolution function obtained from an 85 Sr source with wide coincidence windows. (orig.)

  9. ON THE ANTI-CORRELATION BETWEEN SPECTRAL LINE BROADENING AND INTENSITY IN CORONAL STRUCTURES OBSERVED WITH EIS

    International Nuclear Information System (INIS)

    Scott, J. T.; Martens, P. C. H.

    2011-01-01

    The advance in spectral resolution of the Extreme Ultraviolet Imaging (EIS) spectrometer on board Hinode has allowed for more detailed analysis of coronal spectral lines. Large line broadening and blueshifted velocities have been found in the periphery of active region (AR) cores and near the footpoints of coronal loops. This line broadening is yet to be understood. We study the correlation of intensity and line width for entire ARs and sub-regions selected to include coronal features. The results show that although a slight positive correlation can be found when considering whole images, many sub-regions have a negative correlation between intensity and line width. Sections of a coronal loop display some of the largest anti-correlations found for this study with the increased line broadening occurring directly adjacent to the footpoint section of the loop structure, not at the footpoint itself. The broadened lines may be due to a second Doppler-shifted component that is separate from the main emitting feature such as a coronal loop, but related in their excitation. The small size of these features forces the considerations of investigator and instrumental effects. Preliminary analyses are shown that indicate the possibility of a point-spread function that is not azimuthally symmetric and may affect velocity and line profile measurements.

  10. A temporally and spatially resolved electron density diagnostic method for the edge plasma based on Stark broadening

    Energy Technology Data Exchange (ETDEWEB)

    Zafar, A., E-mail: zafara@ornl.gov [Department of Nuclear Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States); Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830 (United States); Martin, E. H.; Isler, R. C.; Caughman, J. B. O. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830 (United States); Shannon, S. C. [Department of Nuclear Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States)

    2016-11-15

    An electron density diagnostic (≥10{sup 10} cm{sup −3}) capable of high temporal (ms) and spatial (mm) resolution is currently under development at Oak Ridge National Laboratory. The diagnostic is based on measuring the Stark broadened, Doppler-free spectral line profile of the n = 6–2 hydrogen Balmer series transition. The profile is then fit to a fully quantum mechanical model including the appropriate electric and magnetic field operators. The quasi-static approach used to calculate the Doppler-free spectral line profile is outlined here and the results from the model are presented for H-δ spectra for electron densities of 10{sup 10}–10{sup 13} cm{sup −3}. The profile shows complex behavior due to the interaction between the magnetic substates of the atom.

  11. Design of measurement system for Doppler broadening profiles of annihilation radiations as a function of controlled specimen temperature and its applications for a study of metals in the thermal equilibrium state

    International Nuclear Information System (INIS)

    Uedono, Akira; Tanigawa, Shoichiro; Kawano, Takao.

    1992-01-01

    The measurement system for Doppler broadening profiles of annihilation radiation was developed. This system reads out data for energies of γ-rays from an analog to digital converter and those for specimen temperature from a digital-voltmeter coupled to a thermocouple. These two types of digital-quantities were stored in a memory matrix of 512 channels (energy) x 128 channels (temperature) x 4 byte (count). For this purpose, a memory board of 256 kbyte with 32-dynamic RAMs (64 kbits) was used. The data acquisition was controlled by a microcomputer. Temperature of the specimen was controlled by a programmable temperature controller, thus it can be varied in a desired way. This was useful for measurements in repeated temperature cycles. A sample heater with a compact size was developed in order to obtain a homogeneous temperature distribution in the specimen. Application of this system for a study of thermal vacancies in Al-dilute alloys was also shown. (author)

  12. Simultaneous influence of Stark effect and excessive line broadening on the Hα line

    Science.gov (United States)

    Cvetanović, Nikola; Ivković, Saša S.; Obradović, Bratislav M.; Kuraica, Milorad M.

    2017-12-01

    The aim of this paper is to study the combined influence of the Stark effect and the excessive Doppler broadening on the Balmer alpha line in hydrogen discharges. Since this line is a good candidate for measuring electric field in various types of discharges with different gas compositions, a simple method for field measurement based on polarization spectroscopy is developed, that includes all the excitation mechanisms. To simultaneously test the flexibility of the fitting procedure and investigate the excessive broadening, we applied the fitting procedure on line profiles obtained at a range of conditions from two different discharges. The range of pressures and voltages was examined in an abnormal glow and in dielectric barrier discharge operating with hydrogen gas. The model fitting function was able to respond and follow the change in the line profile caused by the change of conditions. This procedure can therefore be recommended for electric field measurement. Contribution to the "Topical Issue: Physics of Ionized Gases (SPIG 2016)", edited by Goran Poparic, Bratislav Obradovic, Dragana Maric and Aleksandar Milosavljevic.

  13. In-vivo imaging of blood flow in human retinal vessels using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    1999-04-01

    Quantification of retinal blood flow may lead to a better understanding of the progression and treatment of several ocular disorders, including diabetic retinopathy, age- related macular degeneration, and glaucoma. Current techniques, such as fluorescein angiography and laser Doppler velocimetry are limited, failing to provide sufficient information to the clinician. Color Doppler optical coherence tomography (CDOCT) is a novel technique using coherent heterodyne detection for simultaneous cross- sectional imaging of tissue microstructure and blood flow. This technique is capable of high spatial and velocity resolution imaging in highly scattering media. We implemented CDOCT for retinal blood flow mapping in human subjects. No dilation of the pupil was necessary. CDOCT is demonstrated for determining bidirectional flow in sub- 100micrometers diameter vessels in the retina. Additionally, we calculated Doppler broadening using the variance of depth- resolved spectra to identify regions with large velocity gradients within the Xenopus heart. This technique may be useful in quantifying local tissue perfusion in highly vascular retinal tissue.

  14. ESR, thermoelectrical and positron annihilation Doppler broadening studies of CuZnFe{sub 2}O{sub 4}-BaTiO{sub 3} composite

    Energy Technology Data Exchange (ETDEWEB)

    Hemeda, O.M. [Physics Department, Faculty of Science, Tanta University, Tanta (Egypt); Mahmoud, K.R. [Physics Department, Faculty of Science, Kafrelsheikh University, Kafr El-Sheikh (Egypt); Sharshar, T. [Physics Department, Faculty of Science, Kafrelsheikh University, Kafr El-Sheikh (Egypt); Physics Department, Faculty of Science, Taif University, Al-Hawiah, Taif, P.O. Box 888 Zip Code 21974 (Saudi Arabia); Elsheshtawy, M. [Physics Department, Faculty of Science, Tanta University, Tanta (Egypt); Hamad, Mahmoud A., E-mail: m_hamad76@yahoo.com [Physics Department, Faculty of Science, Tanta University, Tanta (Egypt); King Marriott Academy for Engineering & Technology, Alexandria (Egypt)

    2017-05-01

    Composite materials of Cu{sub 0.6}Zn{sub 0.4}Fe{sub 2}O{sub 4} (CZF) and barium titanate (BT) with different concentrations were prepared by high energy ball milling method. The composite samples of CZF and BT were studied using Infrared, ESR and positron annihilation Doppler broadening (PADB) spectroscopy techniques as well as thermo-electric power measurements. The results confirm formation of the composite, and presence of two ferrimagnetic and ferroelectric phases, simultaneously. In addition, Fe–O bond for both tetrahedral and octahedral sites, population and distribution of cations at A and B sites are varied with BT content. The values of resonance field, line width of ESR spectrum and charge carrier concentration increase by increasing BT content. The value of the g factor for our samples with low BT content is greater than g-factor value of the isolated free electron. On the contrary, the g-factor values for samples with high BT content are smaller than the free isolated electron. PADB line-shape S-parameter suggests that there are increases of the density of the delocalized electrons, defect size and concentration caused by highly adding BT phase. In addition, PADB results confirm the homogeneity of composite phases and same structure of defects in BT-CZF composite samples. - Highlights: • Composite materials of Cu{sub 0.6}Zn{sub 0.4}Fe{sub 2}O{sub 4} (CZF) and barium titanate (BT) were prepared. • The resonance field and charge carrier concentration increase by increasing BT. • there is increase of the density of delocalized electrons by highly adding BT. • In addition, PADB results confirm the homogeneity of composite phases.

  15. Stark Broadening and White Dwarfs

    Directory of Open Access Journals (Sweden)

    Dimitrijević Milan S.

    2011-12-01

    Full Text Available White dwarf and pre-white dwarfs are the best types of stars for the application of Stark broadening research results in astrophysics, since in the atmospheres of these stars physical conditions are very favorable for this line broadening mechanism - in hot hydrogen-deficient white dwarfs and pre-white dwarfs Teff = 75 000–180 000 K and log g = 5.5–8 [cgs]. Even for much cooler DA and DB white dwarfs with the typical effective temperatures 10 000-20 000 K, Stark broadening is usually the dominant broadening mechanism. In this review, Stark broadening in white dwarf spectra is considered, and the attention is drawn to the STARK-B database (http://stark-b.obspm.fr/, containing the parameters needed for analysis and synthesis of white dwarf spectra, as well as for the collective efforts to develop the Virtual Atomic and Molecular Data Center.

  16. Sub-Doppler spectroscopy

    International Nuclear Information System (INIS)

    Hansch, T.W.

    1983-01-01

    This chapter examines Doppler-free saturation spectroscopy, tunable cw sources, and Doppler-free two-photon spectroscopy. Discusses saturation spectroscopy; continuous wave saturation spectroscopy in the ultraviolet; and two-photon spectroscopy of atomic hydrogen 1S-2S. Focuses on Doppler-free laser spectroscopy of gaseous samples. Explains that in saturation spectroscopy, a monochromatic laser beam ''labels'' a group of atoms within a narrow range of axial velocities through excitation or optical pumping, and a Doppler-free spectrum of these selected atoms is observed with a second, counterpropagating beam. Notes that in two-photon spectroscopy it is possible to record Doppler-free spectra without any need for velocity selection by excitation with two counterpropagating laser beams whose first order Doppler shifts cancel

  17. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  18. Doppler shift measurement of Balmer-alpha line spectrum emission from a plasma in a negative hydrogen ion source

    Energy Technology Data Exchange (ETDEWEB)

    Wada, M., E-mail: mwada@mail.doshisha.ac.jp; Doi, K. [Graduate School of Science and Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321 Japan (Japan); Kisaki, M.; Nakano, H.; Tsumori, K. [National Institute for Fusion Science, Toki, Gifu (Japan); Nishiura, M. [Graduate School of Frontier Sciences, The Universtiy of Tokyo, Chiba 277-8561 (Japan)

    2015-04-08

    Balmer-α light emission from the extraction region of the LHD one-third ion source has shown a characteristic Doppler broadening in the wavelength spectrum detected by a high resolution spectrometer. The spectrum resembles Gaussian distribution near the wavelength of the intensity peak, while it has an additional component of a broader foot. The measured broadening near the wavelength of the intensity peak corresponds to 0.6 eV hydrogen atom temperature. The spectrum exhibits a larger expansion in the blue wing which becomes smaller when the line of sight is tilted toward the driver region from the original observation axis parallel to the plasma grid. A surface collision simulation model predicts the possibility of hydrogen reflection at the plasma grid surface to form a broad Balmer-α light emission spectrum.

  19. Doppler shift measurement of Balmer-alpha line spectrum emission from a plasma in a negative hydrogen ion source

    International Nuclear Information System (INIS)

    Wada, M.; Doi, K.; Kisaki, M.; Nakano, H.; Tsumori, K.; Nishiura, M.

    2015-01-01

    Balmer-α light emission from the extraction region of the LHD one-third ion source has shown a characteristic Doppler broadening in the wavelength spectrum detected by a high resolution spectrometer. The spectrum resembles Gaussian distribution near the wavelength of the intensity peak, while it has an additional component of a broader foot. The measured broadening near the wavelength of the intensity peak corresponds to 0.6 eV hydrogen atom temperature. The spectrum exhibits a larger expansion in the blue wing which becomes smaller when the line of sight is tilted toward the driver region from the original observation axis parallel to the plasma grid. A surface collision simulation model predicts the possibility of hydrogen reflection at the plasma grid surface to form a broad Balmer-α light emission spectrum

  20. Line broadening by focusing

    International Nuclear Information System (INIS)

    Brito, A.L. de; Jabs, A.

    1983-01-01

    It is pointed out that the spectral width of a quasi-monochromatic light beam broadens when the beam is focused. A quantitative formula for this broadening is derived from classical wave theory. The effect is shown to explain some experiments on laser beams done by E. Panarella which that author has explained under the ad-hoc hypothesis that the frequency of the photons changes along with the intensity of the light beam. The line broadening by focusing might also contribute to gas ionization by incident light when the ionization potential is well above the mean photon energy. Some remarks are made on some direct applications of the Heisenberg relations in comparison with our treatment. (Author) [pt

  1. Study of Compton broadening due to electron-photon scattering

    Directory of Open Access Journals (Sweden)

    Srinivasa Rao M.

    2010-01-01

    Full Text Available We have investigated the effects of Compton broadening due to electron-photon scattering in hot stellar atmospheres. A purely electron-photon scattering media is assumed to have plane parallel geometry with an input radia­tion field localized on one side of the slab. The method is based on the discrete space theory of radiative transfer for the intensity of emitted radiation. The solution is developed to study the importance of scattering of radiation by free electrons in high temperature stellar atmospheres which produces a brodening and shift in spectral lines because of the Compton effect and the Doppler effect arising from mass and thermal motions of scattering electrons. It is noticed that the Comptonized spectrum depends on three parameters: the optical depth of the medium, the temperature of the thermal electrons and the viewing angle. We also showed that the Compton effect produces red shift and asymmetry in the line. These two effects increase as the optical depth increases. It is also noticed that the emergent specific intensities become completely asymmetric for higher optical depths.

  2. Study of Compton Broadening Due to Electron-Photon Scattering

    Directory of Open Access Journals (Sweden)

    Srinivasa Rao, M.

    2010-06-01

    Full Text Available We have investigated the effects of Compton broadening due to electron-photon scattering in hot stellar atmospheres. A purely electron-photon scattering media is assumed to have plane parallel geometry with an input radiation field localized on one side of the slab. The method is based on the discrete space theory of radiative transfer for the intensity of emitted radiation.The solution is developed to study the importance of scattering of radiation by free electrons in high temperature stellar atmospheres which produces a brodening and shift in spectral lines because of the Compton effect and the Doppler effect arising from mass and thermal motions of scattering electrons.It is noticed that the Comptonized spectrum depends on three parameters: the optical depth of the medium, the temperature of the thermal electrons and the viewing angle.We also showed that the Compton effect produces red shift and asymmetry in the line. These two effects increase as the optical depth increases. It is also noticed that the emergent specific intensities become completely asymmetric for higher optical depths.

  3. Improved algorithms for the calculation of resolved resonance cross sections with applications to the structural Doppler effect in fast reactors

    International Nuclear Information System (INIS)

    Hwang, R.N.; Toppel, B.J.; Henryson, H. II.

    1980-10-01

    Motivated by a need for an economical yet rigorous tool which can address the computation of the structural material Doppler effect, an extremely efficient improved RABANL capability has been developed utilizing the fact that the Doppler broadened line shape functions become essentially identical to the natural line shape functions or Lorentzian limits beyond about 100 Doppler widths from the resonance energy, or when the natural width exceeds about 200 Doppler widths. The computational efficiency has been further enhanced by preprocessing or screening a significant number of selected resonances during library preparation into composition and temperature independent smooth background cross sections. The resonances which are suitable for such pre-processing are those which are either very broad or those which are very weak. The former contribute very little to the Doppler effect and their self-shielding effect can readily be averaged into slowly varying background cross section data, while the latter contribute very little to either the Doppler or to self-shielding effects. To illustrate the accuracy and efficiency of the improved RABANL algorithms and resonance screening techniques, calculations have been performed for two systems, the first with a composition typical of the STF converter region and the second typical of an LMFBR core composition. Excellent agreement has been found for RABANL compared to the reference Monte Carlo solution obtained using the code VIM, and improved results have also been obtained for the narrow resonance approximation in the ultra-fine-group option of MC 2 -2

  4. SCANDI – an all-sky Doppler imager for studies of thermospheric spatial structure

    Directory of Open Access Journals (Sweden)

    A. L. Aruliah

    2010-02-01

    Full Text Available A new all-sky Fabry-Perot Interferometer called the Scanning Doppler Imager (SCANDI was built and installed at Longyearbyen in December 2006. Observations have been made of the Doppler shifts and Doppler broadening of the 630 nm airglow and aurora, from which upper thermospheric winds and temperatures are calculated. SCANDI allows measurements over a field-of-view (FOV with a horizontal radius of nearly 600 km for observations at an altitude of 250 km using a time resolution of 8 min. The instrument provides the ability to observe thermospheric spatial structure within a FOV which overlaps that of the EISCAT Svalbard radar and CUTLASS SuperDARN radars. Coordinating with these instruments provides an important opportunity for studying ion-neutral coupling. The all-sky image is divided into several sectors to provide a horizontal spatial resolution of between 100–300 km. This is a powerful extension in observational capability but requires careful calibration and data analysis, as described here. Two observation modes were used: a fixed and a scanning etalon gap. SCANDI results are corroborated using the Longyearbyen single look direction FPI, and ESR measurements of the ion temperatures. The data show thermospheric temperature gradients of a few Kelvins per kilometre, and a great deal of meso-scale variability on spatial scales of several tens of kilometres.

  5. Comparisons between PW Doppler system and enhanced FM Doppler system

    DEFF Research Database (Denmark)

    Wilhjelm, Jens E.; Pedersen, P. C.

    1995-01-01

    This paper presents a new implementation of an echo-ranging FM Doppler system with improved performance, relative to the FM Doppler system reported previously. The use of long sweeps provides a significant reduction in peak to average power ratio compared to pulsed wave (PW) emission. A PW Doppler...... system exploits the direct relationship between arrival time of the received signal and range from the transducer. In the FM Doppler systems, a similar relationship exists in the spectral domain of the demodulated received signals, so that range is represented by frequency. Thus, a shift in location...... of moving scatterers between consecutive emissions corresponds to a frequency shift in the spectral signature. The improvement relative to the earlier version of the FM Doppler system is attained by utilizing cross-correlation of real spectra rather than of magnitude spectra for assessing flow velocity...

  6. NDT oriented equipment for observing the Doppler broadening of radiation produced by the annihilation of positrons in cylindrical samples

    International Nuclear Information System (INIS)

    Coleman, C.F.; Smith, F.A.; Hughes, A.E.

    1976-11-01

    This report describes the development of equipment for measuring annihilation line broadening in cylindrical samples a few millimetres in diameter, suitable for use in fatigue testing programs. A detached positron source is employed, allowing the samples to be scanned both longitudinally (resolution approximately 1 cm) and in azimuth. Some of the advantages of and problems associated with this configuration are discussed. The statistical precision of a number of parameters

  7. RESEND, Infinitely Dilute Point Cross-Sections Calculation from ENDF/B Resonance Parameter. ADLER, ENDF/B Adler-Adler Resonance Parameter to Point Cross-Sections with Doppler Broadening

    International Nuclear Information System (INIS)

    Bhat, M.R.; Ozer, O.

    1982-01-01

    1 - Description of problem or function: RESEND generates infinitely- dilute, un-broadened, point cross sections in the ENDF format by combining ENDF File 3 background cross sections with points calculated from ENDF File 2 resonance parameter data. ADLER calculates total, capture, and fission cross sections from the corresponding Adler-Adler parameters in the ENDF/B File 2 Version II data and also Doppler-broadens cross sections. 2 - Method of solution: RESEND calculations are done in two steps by two separate sections of the program. The first section does the resonance calculation and stores the results on a scratch file. The second section combines the data from the scratch file with background cross sections and prints the results. ADLER uses the Adler-Adler formalism. 3 - Restrictions on the complexity of the problem: RESEND expects its input to be a standard mode BCD ENDF file (Version II/III). Since the output is also a standard mode BCD ENDF file, the program is limited by the six significant figure accuracy inherent in the ENDF formats. (If the cross section has been calculated at two points so close in energy that only their least significant figures differ, that interval is assumed to have converged, even if other convergence criteria may not be satisfied.) In the unresolved range the cross sections have been averaged over a Porter-Thomas distribution. In some regions the calculated resonance cross sections may be negative. In such cases the standard convergence criterion would cause an unnecessarily large number of points to be produced in the region where the cross section becomes zero. For this reason an additional input convergence criterion (AVERR) may be used. If the absolute value of the cross section at both ends of an interval is determined to be less than AVERR then the interval is assumed to have converged. There are no limitations on the total number of points generated. The present ENDF (Version II/III) formats restrict the total number of

  8. Turbulent energy dissipation rates observed by Doppler MST Radar and by rocket-borne instruments during the MIDAS/MaCWAVE campaign 2002

    Directory of Open Access Journals (Sweden)

    N. Engler

    2005-06-01

    Full Text Available During the MIDAS/MaCWAVE campaign in summer 2002 we have observed turbulence using Doppler beam steering measurements obtained from the ALWIN VHF radar at Andøya/Northern Norway. This radar was operated in the Doppler beam steering mode for turbulence investigations during the campaign, as well as in spaced antenna mode, for continuously measuring the background wind field. The real-time data analysis of the Doppler radar backscattering provided the launch conditions for the sounding rockets. The spectral width data observed during the occurrence of PMSE were corrected for beam and shear broadening caused by the background wind field to obtain the turbulent part of the spectral width. The turbulent energy dissipation rates determined from the turbulent spectral width vary between 5 and 100mW kg-1 in the altitude range of 80-92km and increase with altitude. These estimations agree well with the in-situ measurements using the CONE sensor which was launched on 3 sounding rockets during the campaign.

  9. Depth-selective 2D-ACAR and coincidence Doppler investigation of embedded Au nanocrystals in MgO

    International Nuclear Information System (INIS)

    Eijt, S.W.H.; Veen, A. van; Falub, C.V.; Schut, H.; Huis, M.A. van; Mijnarends, P.E.

    2004-01-01

    We present a depth-selective 2D-ACAR and two-detector Doppler broadening study on Au nanocrystals in monocrystalline MgO(100), produced in sub-surface layers by ion implantation and subsequent thermal annealing to temperatures beyond the stability range of vacancy clusters in MgO. In contrast to the case of Li nanocrystals, it was found that positrons do not trap inside the Au nanocrystals, but only in defects at the nanocrystal-to-host interface (attached vacancy clusters). This is interpreted in terms of the positron affinity of Au, MgO and the defects. (orig.)

  10. Depth-selective 2D-ACAR and coincidence Doppler investigation of embedded Au nanocrystals in MgO

    Energy Technology Data Exchange (ETDEWEB)

    Eijt, S.W.H.; Veen, A. van; Falub, C.V.; Schut, H.; Huis, M.A. van [Interfaculty Reactor Inst., Delft Univ. of Technology, Delft (Netherlands); Mijnarends, P.E. [Interfaculty Reactor Inst., Delft Univ. of Technology, Delft (Netherlands); Dept. of Physics, Northeastern Univ., Boston, MA (United States)

    2004-07-01

    We present a depth-selective 2D-ACAR and two-detector Doppler broadening study on Au nanocrystals in monocrystalline MgO(100), produced in sub-surface layers by ion implantation and subsequent thermal annealing to temperatures beyond the stability range of vacancy clusters in MgO. In contrast to the case of Li nanocrystals, it was found that positrons do not trap inside the Au nanocrystals, but only in defects at the nanocrystal-to-host interface (attached vacancy clusters). This is interpreted in terms of the positron affinity of Au, MgO and the defects. (orig.)

  11. Low arousing positive affect broadens visual attention and alters the thought-action repertoire while broadened visual attention does not

    Directory of Open Access Journals (Sweden)

    Daniel Thomas Jäger

    2016-10-01

    Full Text Available The Broaden-and-Build Theory states that positive emotions broaden cognition and therefore build personal resources. However, missing theoretical precision regarding the interaction of the cognitive processes involved offers a variety of possible explanations for the mechanisms of broadening and building. In Experiment 1 we tested the causality assumption which states that positive emotions first broaden visual attention which in turn leads to broadened cognition. We examined the effects of a broadened, narrowed or neutral attentional scope of 72 subjects (30 men on their momentary thought-action repertoire. Results showed that there were no significant differences between groups regarding the breadth or the content of the thought-action repertoire. In Experiment 2 we studied the non-causality hypothesis which assumes a non-causal relationship between cognitive processes. We did so by investigating the effects of negative, neutral, and positive affect on the visual attentional scope of 85 subjects (41 men in Experiment 2a, as well as on the thought-action repertoire of 85 participants (42 men in Experiment 2b. Results revealed an attentional broadening effect in Experiment 2a but no differences between groups concerning the breadth of the thought-action repertoire in Experiment 2b. However, a theory driven content analysis showed that positive affect promoted social actions whereas negative affect endorsed resource protecting actions. Thus, our results favor the non-causality assumption. Moreover, results indicate that positive emotions do not target personal resources in general but rather resources associated with social behavior. In conclusion, we argue that the Broaden-and-Build Theory should be refined.

  12. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    International Nuclear Information System (INIS)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions

  13. Stratospheric temperature measurement with scanning Fabry-Perot interferometer for wind retrieval from mobile Rayleigh Doppler lidar.

    Science.gov (United States)

    Xia, Haiyun; Dou, Xiankang; Shangguan, Mingjia; Zhao, Ruocan; Sun, Dongsong; Wang, Chong; Qiu, Jiawei; Shu, Zhifeng; Xue, Xianghui; Han, Yuli; Han, Yan

    2014-09-08

    Temperature detection remains challenging in the low stratosphere, where the Rayleigh integration lidar is perturbed by aerosol contamination and ozone absorption while the rotational Raman lidar is suffered from its low scattering cross section. To correct the impacts of temperature on the Rayleigh Doppler lidar, a high spectral resolution lidar (HSRL) based on cavity scanning Fabry-Perot Interferometer (FPI) is developed. By considering the effect of the laser spectral width, Doppler broadening of the molecular backscatter, divergence of the light beam and mirror defects of the FPI, a well-behaved transmission function is proved to show the principle of HSRL in detail. Analysis of the statistical error of the HSRL is carried out in the data processing. A temperature lidar using both HSRL and Rayleigh integration techniques is incorporated into the Rayleigh Doppler wind lidar. Simultaneous wind and temperature detection is carried out based on the combined system at Delhi (37.371°N, 97.374°E; 2850 m above the sea level) in Qinghai province, China. Lower Stratosphere temperature has been measured using HSRL between 18 and 50 km with temporal resolution of 2000 seconds. The statistical error of the derived temperatures is between 0.2 and 9.2 K. The temperature profile retrieved from the HSRL and wind profile from the Rayleigh Doppler lidar show good agreement with the radiosonde data. Specifically, the max temperature deviation between the HSRL and radiosonde is 4.7 K from 18 km to 36 km, and it is 2.7 K between the HSRL and Rayleigh integration lidar from 27 km to 34 km.

  14. Dual-Doppler Feasibility Study

    Science.gov (United States)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  15. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Science.gov (United States)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  16. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Sumit Goel

    2011-01-01

    Full Text Available Aim: To evaluate the efficacy of ultrasonography (USG with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas. There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions.

  17. Level width broadening effect

    International Nuclear Information System (INIS)

    Zhang Jingshang

    2003-01-01

    In file-6 for double-differential cross sections, the level width broadening effect should be taken into account properly due to Heisenberg' uncertainty. Besides level width broadening effect, the energy resolution in the measurements is also needed in fitting measurement procedure. In general, the traditional normal Gaussian expansion is employed. However, to do so in this way the energy balance could not be held. For this reason, the deformed Gaussian expansion functions with exponential form for both the single energy point and continuous spectrum are introduced, with which the normalization and energy balance conditions could be held exactly in the analytical form. (author)

  18. Comparison of power Doppler and color Doppler ultrasonography in the detection of intrasticular blood flow of normal infants

    International Nuclear Information System (INIS)

    Shin, Sung Ran; Lee, Ho Kyoung; Lee, Won Gyun; Youk, Dong Joon; Rho, Taek Soo; Lee, Min Jin; Lee, Sang Chun

    1999-01-01

    To compare color Doppler ultrasonography (US) and power Doppler US in the detection of intratesticular blood flow in normal infants and to asses the symmetry of blood flow. Testicular blood flow was assessed prospectively in 100 testes of 50 infants with both power and color Doppler US. We compared the power Doppler with color Doppler to detect intratesticular blood. When the flow was detected, intratesticular blood flow was graded as follows: grade 1: single intratesticular Doppler signal ; grade 2: multiple intratesticular Doppler signals. The symmetry of intratesticular flow was assessed by using the same method. Intratesticular flow was detected in 72 (72%) and 68 (68%) testes on power and color Doppler US, respectively. In 76 testes (76%), intratesticular flow was detected in either one or both techniques. On power Doppler US, grade 1 was seen in 40 tests and grade 2 in 32 testes. On color Doppler US, grade 1 was noted in 52 testes and grade 2 in 16 testes. Testicular blood flow was symmetric on both power and color Doppler US in each patient. There was no difference between power Doppler and color Doppler ultrasonography in detecting intratesticular blood flow in normal infants.

  19. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  20. Gallblader varices in children with portal cavernoma: duplex-Doppler and color Doppler ultrasound studies

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Lopez, A.

    1998-01-01

    To determine the prevalence of varices in the gallbladder wall, observed by duplex-Doppler and color Doppler ultrasound, in children with cavernoma of the portal vein. Nineteen patients with portal hypertension were studied prospectively by duplex-Doppler and color Doppler ultrasound: 12 of the patients had developed a cavernoma of the portal vein. The presence of peri vesicular varices was assessed in the group of patients with portal cavernoma. Duplex-Doppler and color Doppler ultrasound disclosed the presence of varices in gallbladder wall in nine of the 12 patients (75%). The varices appeared as anechoic and serpiginous areas, and Doppler ultrasound revealed slowed venous flow. However, the three patients in whom gallbldder varices were not detected presented collateral gastric ciculation and spontaneous splenorenal shunt. Gallbladder varices are common in children with portal vein cavernoma; they present hepatopetal flow. Their developments is not related to the size of the portal cavernoma, the presence of spontaneous portosystemic shunts, or endoscopic obliteration of gastric and esophageal varices. The detection of gallbladder varices in patients with portal hypertension who are to undergo biliary surgery is highly important for the surgeon, helping to avoid perioperative complications. (Author) 15 refs

  1. Avaliação dos tumores hepáticos ao Doppler Doppler evaluation of liver tumors

    Directory of Open Access Journals (Sweden)

    Márcio Martins Machado

    2004-10-01

    Full Text Available Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler". Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.Recent advances in ultrasound have optimized the detection of liver tumors and helped to improve the prognosis of patients with this condition as newly developed and improved therapeutic modalities have been established. The authors review important Doppler findings which may help in the identification and characterization of some hepatic tumors through the evaluation of color Doppler, pulsed Doppler and power Doppler features. New imaging methods such as the use of harmonics imaging are also reviewed.

  2. Doppler evaluation of valvular stenosis

    International Nuclear Information System (INIS)

    Kisslo, J.; Krafchek, J.; Adams, D.; Mark, D.B.

    1986-01-01

    One of the reasons why use of Doppler echocardiography is growing rapidly is because of its utility in detecting the presence of valvular stenosis and in estimating its severity. Detection of the presence of stenotic valvular heart disease using Doppler echocardiography was originally described over 10 years ago. It has been demonstrated that Doppler blood velocity data could be used to estimate the severity of a stenotic lesion. This chapter discusses the evaluation of valvular stenois using Doppler

  3. The Cognitive Doppler.

    Science.gov (United States)

    Kozoil, Micah E.

    1989-01-01

    Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…

  4. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    Peripheral vascular disease - Doppler; PVD - Doppler; PAD - Doppler; Blockage of leg arteries - Doppler; Intermittent claudication - Doppler; Arterial insufficiency of the legs - Doppler; Leg pain and ...

  5. Exciton broadening in WS2 /graphene heterostructures

    International Nuclear Information System (INIS)

    Hill, Heather M.; Rigosi, Albert F.; Raja, Archana

    2017-01-01

    Here, we have used optical spectroscopy to observe spectral broadening of WS 2 exciton reflectance peaks in heterostructures of monolayer WS 2 capped with mono- to few-layer graphene. The broadening is found to be similar for the A and B excitons and on the order of 5–10 meV. No strong dependence on the number of graphene layers was observed within experimental uncertainty. The broadening can be attributed to charge- and energy-transfer processes between the two materials, providing an observed lower bound for the corresponding time scales of 65 fs.

  6. Determination of ion temperatures from Zeeman broadened spectral lines in the edge of Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Klepper, C.C.; Isler, R.C.; Tobin, S.J.; Hogan, J.T. [Oak Ridge National Lab., TN (United States). Fusion Energy Div.; Hess, W.R. [Association EURATOM-CEA sur la Fusion Controlee, St-Paul-lez-Durance (France). Centre d`Etudes de Cadarache

    1994-09-01

    The authors have examined a {sup 3}P {yields} {sup 3}S multiplet of C III in Tore Supra in order to assess the possibility of determining the ion temperatures from transitions where the Zeeman effect cannot be neglected compared to the Doppler broadening. The preliminary studies lead them to believe that with good quality data the temperatures can be determined within about 20% in the 20--30 eV range and within about 50% in the neighborhood of 5 eV by fitting the entire multiplet rather than a semi-isolated feature, even though certain parameters important for the analysis, such as polarization effects of the optics, are not well characterized. In order to quantify these conclusions more precisely, future work will concentrate on developing numerical fitting routines and on examining the validity of the assumption that the distribution function for low ionization stages is Maxwellian.

  7. Determination of ion temperatures from Zeeman broadened spectral lines in the edge of Tore Supra

    International Nuclear Information System (INIS)

    Klepper, C.C.; Isler, R.C.; Tobin, S.J.; Hogan, J.T.; Hess, W.R.

    1994-01-01

    The authors have examined a 3 P → 3 S multiplet of C III in Tore Supra in order to assess the possibility of determining the ion temperatures from transitions where the Zeeman effect cannot be neglected compared to the Doppler broadening. The preliminary studies lead them to believe that with good quality data the temperatures can be determined within about 20% in the 20--30 eV range and within about 50% in the neighborhood of 5 eV by fitting the entire multiplet rather than a semi-isolated feature, even though certain parameters important for the analysis, such as polarization effects of the optics, are not well characterized. In order to quantify these conclusions more precisely, future work will concentrate on developing numerical fitting routines and on examining the validity of the assumption that the distribution function for low ionization stages is Maxwellian

  8. Doppler flowmetry in preeclampsia.

    Science.gov (United States)

    Zahumensky, J

    2009-01-01

    The purpose of this study was to summarize the new published data on the Doppler flowmetry in preeclampsia. We summarize the new published data on the Doppler flowmetry in uteroplacental, fetoplacental and fetal circulation in preeclampsia. The present review summarized the results of clinical research on the Doppler flowmetry in the screening of risk of preclampsia, in the diagnosis of preclampsia and in the fetal risk in preclampsia (Ref. 19). Full Text (Free, PDF) www.bmj.sk.

  9. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  10. Doppler radar flowmeter

    Science.gov (United States)

    Petlevich, Walter J.; Sverdrup, Edward F.

    1978-01-01

    A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.

  11. A doppler-based evaluation of peripheral lower limb arterial insufficiency in diabetes mellitus

    International Nuclear Information System (INIS)

    Shaheen, R.; Sohail, S.

    2010-01-01

    To determine the frequency, level and flow patterns of lower limb arterial insufficiency in diabetic patients on Doppler ultrasound study. Study Design: Cross-sectional study. Place and Duration of Study: Radiology Department, Civil Hospital, Karachi, from February 2007 to September 2008. Methodology: One hundred adult diabetic patients with suspected peripheral vascular insufficiency irrespective of gender were included. Demographic data, presenting complaints, treatment history, and level of HbA1c were recorded. Doppler evaluated arterial status and ankle brachial index (ABI) were recorded on proforma. Statistical analysis were done on SPSS version 12. Results: The mean HbA1c was 8.4 +- 1.4 gm/dl, a majority of 77% having a controlled level of < 10 mg/dl. Arterial insufficiency on Doppler ultrasound was documented in 62% (p=0.016) and the dorsalis paedis artery was the predominant site of stenosis (24%). Spectral broadening and biphasic flow were salient features. The mean value of resistive index in stenotic cases was 0.563 +- 0.16 with a mean velocity difference of 0.37 +- 0.29 m/s (p < 0.001) at the site of stenosis. Conclusion: Peripheral vascular insufficiency was a significant finding in patients having diabetes for an average of 9.8 years, even in the presence of controlled HbA1c. The dorsalis paedis was the commonest site of involvement. The insufficiency was moderate with a biphasic flow pattern in a majority of cases. Difference in resistive index and flow velocities at and above the site of stenosis provided an important clue to the diagnosis of level of stenosis that helps in planning limb salvage management. (author)

  12. Spatial weighting of Doppler reactivity feedback

    International Nuclear Information System (INIS)

    Carew, J.F.; Diamond, D.J.; Todosow, M.

    1977-12-01

    The spatial weighting of the local Doppler feedback implicit in the determination of the core Doppler feedback reactivity has been investigated. Using a detailed planar PDQ7-II PWR model with local fuel-temperature feedback, the core Doppler spatial weight factor, S, has been determined for various control patterns and power levels. Assuming power-squared weighting of the local Doppler feedback, a simple analytic expression for S has been derived and, based on comparison with the PDQ7-II results, provides a convenient and accurate representation of the Doppler spatial weight factor. The sensitivity of these results to variations in the fuel rod heat transfer coefficients, fuel loading and the magnitude of the Doppler coefficient has also been evaluated. The dependence of the local Doppler coefficient on moderator temperature, boron concentration and control rod density has been determined and found to be weak. Selected comparisons with vendor analyses have been made and indicate general agreement

  13. Doppler spectroscopy of hydrogen Balmer lines in a hollow cathode glow discharge in ammonia and argon-ammonia mixture

    International Nuclear Information System (INIS)

    Sisovic, N. M.; Konjevic, N.

    2008-01-01

    The results of Doppler spectroscopy of hydrogen Balmer lines from a stainless steel (SS) and copper (Cu) hollow cathode (HC) glow discharge in ammonia and argon-ammonia mixture are reported. The experimental profiles in ammonia discharge are fitted well by superposing three Gaussian profiles. The half widths, in energy units, of narrow and medium Gaussians are in the ranges 0.3-0.4 eV and 3-4 eV, respectively, for both hollow cathodes what is expected on the basis of earlier electron beam→NH 3 experiments. The half widths of the largest Gaussian in ammonia are 46 and 55 eV for SS and Cu HC, respectively. In argon-ammonia discharge, three Gaussians are also required to fit experimental profiles. While half widths of narrow and medium Gaussians are similar to those in ammonia, the half widths of the largest Gaussians are 35 and 42 eV for SS and Cu HC, respectively. The half widths of the largest Gaussians in ammonia and in argon-ammonia mixture indicate the presence of excessive Doppler broadening.

  14. Study of the movement of oxygen vacancies in the orthorhombic phase of YBa2Cu3O7-x by positron Doppler broadening spectroscopy

    International Nuclear Information System (INIS)

    Hong Zhang; Xiao-Gan Wang; Yao-Xian Fu

    1988-01-01

    The positron annihilation Doppler spectroscopy is used to monitor the movement of oxygen vacancy of YBa 2 Cu 3 O 7-x and an activation energy of (0.80 ± 0.10) eV for migration of oxygen vacancy in orthorhombic phase is obtained. (author)

  15. Flow angle dependent photoacoustic Doppler power spectra under intensity-modulated continuous wave laser excitation

    Directory of Open Access Journals (Sweden)

    Yu Tong

    2016-02-01

    Full Text Available Photoacoustic Doppler (PAD power spectra showing an evident Doppler shift represent the major characteristics of the continuous wave-excited or burst wave-excited versions of PAD flow measurements. In this paper, the flow angle dependences of the PAD power spectra are investigated using an experiment setup that was established based on intensity-modulated continuous wave laser excitation. The setup has an overall configuration that is similar to a previously reported configuration, but is more sophisticated in that it accurately aligns the laser illumination with the ultrasound detection process, and in that it picks up the correct sample position. In the analysis of the power spectra data, we find that the background power spectra can be extracted by combining the output signals from the two channels of the lock-in amplifier, which is very useful for identification of the PAD power spectra. The power spectra are presented and analyzed in opposite flow directions, at different flow speeds, and at different flow angles. The power spectra at a 90° flow angle show the unique properties of symmetrical shapes due to PAD broadening. For the other flow angles, the smoothed power spectra clearly show a flow angle cosine relationship.

  16. Pressure broadening and pressure shift of diatomic iodine at 675 nm

    Science.gov (United States)

    Wolf, Erich N.

    Doppler-limited, steady-state, linear absorption spectra of 127 I2 (diatomic iodine) near 675 nm were recorded with an internally-referenced wavelength modulation spectrometer, built around a free-running diode laser using phase-sensitive detection, and capable of exceeding the signal-to-noise limit imposed by the 12-bit data acquisition system. Observed I2 lines were accounted for by published spectroscopic constants. Pressure broadening and pressure shift coefficients were determined respectively from the line-widths and line-center shifts as a function of buffer gas pressure, which were determined from nonlinear regression analysis of observed line shapes against a Gaussian-Lorentzian convolution line shape model. This model included a linear superposition of the I2 hyperfine structure based on changes in the nuclear electric quadrupole coupling constant. Room temperature (292 K) values of these coefficients were determined for six unblended I 2 lines in the region 14,817.95 to 14,819.45 cm-1 for each of the following buffer gases: the atoms He, Ne, Ar, Kr, and Xe; and the molecules H2, D2, N2, CO2, N2O, air, and H2O. These coefficients were also determined at one additional temperature (388 K) for He and CO2, and at two additional temperatures (348 and 388 K) for Ar. Elastic collision cross-sections were determined for all pressure broadening coefficients in this region. Room temperature values of these coefficients were also determined for several low-J I2 lines in the region 14,946.17 to 14,850.29 cm-1 for Ar. A line shape model, obtained from a first-order perturbation solution of the time-dependent Schrodinger equation for randomly occurring interactions between a two-level system and a buffer gas treated as step-function potentials, reveals a relationship between the ratio of pressure broadening to pressure shift coefficients and a change in the wave function phase-factor, interpreted as reflecting the "cause and effect" of state-changing events in the

  17. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  18. Broadening the radiography spectrum

    International Nuclear Information System (INIS)

    Waswa, L.; Mutwasi, O.; Kioko, J.

    2006-05-01

    The text discuses the mammography in breast screening and evaluation of breast cancer; Small parts ultrasounds at plaza imaging solutions; role of a Radiographer in mammography-new perspective; Medical imaging education in africa; Caring for the paediatric patient as to broaden radiotherapy spectrum; Problems and challenges in care for children undergoing radiotherapy; Paediatric radiotherapy, management and side effects; The principles of pattern recognition of skeletal structures; the place of distance learning education in broadening the radiography spectrum; the curriculum and budgeting image; sonographer's guide; Computed radiography- X-Ray with vision; digital Radiography in Kenya today; Particle Therapy at Ithemba Labs; The role of lung perfusion and ventilation study in the evaluation of the pulmonary embolism and lastly, an overview of Head and neck treatment at Kenyatta National hospital radiotherapy

  19. Doppler ultrasound monitoring technology.

    Science.gov (United States)

    Docker, M F

    1993-03-01

    Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.

  20. Differential doppler heterodyning technique

    DEFF Research Database (Denmark)

    Lading, Lars

    1971-01-01

    Measuring velocity without disturbing the moving object is possible by use of the laser doppler heterodyning technique. Theoretical considerations on the doppler shift show that the antenna property of the photodetector can solve an apparent conflict between two different ways of calculating...

  1. Burst Format Design for Optimum Joint Estimation of Doppler-Shift and Doppler-Rate in Packet Satellite Communications

    Directory of Open Access Journals (Sweden)

    Luca Giugno

    2007-05-01

    Full Text Available This paper considers the problem of optimizing the burst format of packet transmission to perform enhanced-accuracy estimation of Doppler-shift and Doppler-rate of the carrier of the received signal, due to relative motion between the transmitter and the receiver. Two novel burst formats that minimize the Doppler-shift and the Doppler-rate Cramér-Rao bounds (CRBs for the joint estimation of carrier phase/Doppler-shift and of the Doppler-rate are derived, and a data-aided (DA estimation algorithm suitable for each optimal burst format is presented. Performance of the newly derived estimators is evaluated by analysis and by simulation, showing that such algorithms attain their relevant CRBs with very low complexity, so that they can be directly embedded into new-generation digital modems for satellite communications at low SNR.

  2. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  3. Doppler tomography in fusion plasmas and astrophysics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Heidbrink, W. W.

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion Dα (FIDA) spectroscopy measurements in magnetically confined plasma......, the Dα-photons are likewise Doppler-shifted ultimately due to gyration of the fast ions. In either case, spectra of Doppler-shifted line emission are sensitive to the velocity distribution of the emitters. Astrophysical Doppler tomography has lead to images of accretion discs of binaries revealing bright...... and limits, analogies and differences in astrophysical and fusion plasma Doppler tomography and what can be learned by comparison of these applications....

  4. Doppler-guided retrograde catheterization system

    Science.gov (United States)

    Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.

    1991-05-01

    The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the

  5. Coherent optical transients observed in rubidium atomic line filtered Doppler velocimetry experiments

    Energy Technology Data Exchange (ETDEWEB)

    Fajardo, Mario E., E-mail: mario.fajardo@eglin.af.mil; Molek, Christopher D.; Vesely, Annamaria L. [Air Force Research Laboratory, Munitions Directorate, Ordnance Division, Energetic Materials Branch, AFRL/RWME, 2306 Perimeter Road, Eglin AFB, Florida 32542-5910 (United States)

    2015-10-14

    We report the first successful results from our novel Rubidium Atomic Line Filtered (RALF) Doppler velocimetry apparatus, along with unanticipated oscillatory signals due to coherent optical transients generated within pure Rb vapor cells. RALF is a high-velocity and high-acceleration extension of the well-known Doppler Global Velocimetry (DGV) technique for constructing multi-dimensional flow velocity vector maps in aerodynamics experiments [H. Komine, U.S. Patent No. 4,919,536 (24 April 1990)]. RALF exploits the frequency dependence of pressure-broadened Rb atom optical absorptions in a heated Rb/N{sub 2} gas cell to encode the Doppler shift of reflected near-resonant (λ{sub 0} ≈ 780.24 nm) laser light onto the intensity transmitted by the cell. The present RALF apparatus combines fiber optic and free-space components and was built to determine suitable operating conditions and performance parameters for the Rb/N{sub 2} gas cells. It yields single-spot velocities of thin laser-driven-flyer test surfaces and incorporates a simultaneous Photonic Doppler Velocimetry (PDV) channel [Strand et al., Rev. Sci. Instrum. 77, 083108 (2006)] for validation of the RALF results, which we demonstrate here over the v = 0 to 1 km/s range. Both RALF and DGV presume the vapor cells to be simple Beer's Law optical absorbers, so we were quite surprised to observe oscillatory signals in experiments employing low pressure pure Rb vapor cells. We interpret these oscillations as interference between the Doppler shifted reflected light and the Free Induction Decay (FID) coherent optical transient produced within the pure Rb cells at the original laser frequency; this is confirmed by direct comparison of the PDV and FID signals. We attribute the different behaviors of the Rb/N{sub 2} vs. Rb gas cells to efficient dephasing of the atomic/optical coherences by Rb-N{sub 2} collisions. The minimum necessary N{sub 2} buffer gas density ≈0.3 amagat translates into a

  6. Lagrange polynomial interpolation method applied in the calculation of the J({xi},{beta}) function

    Energy Technology Data Exchange (ETDEWEB)

    Fraga, Vinicius Munhoz; Palma, Daniel Artur Pinheiro [Centro Federal de Educacao Tecnologica de Quimica de Nilopolis, RJ (Brazil)]. E-mails: munhoz.vf@gmail.com; dpalma@cefeteq.br; Martinez, Aquilino Senra [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE) (COPPE). Programa de Engenharia Nuclear]. E-mail: aquilino@lmp.ufrj.br

    2008-07-01

    The explicit dependence of the Doppler broadening function creates difficulties in the obtaining an analytical expression for J function . The objective of this paper is to present a method for the quick and accurate calculation of J function based on the recent advances in the calculation of the Doppler broadening function and on a systematic analysis of its integrand. The methodology proposed, of a semi-analytical nature, uses the Lagrange polynomial interpolation method and the Frobenius formulation in the calculation of Doppler broadening function . The results have proven satisfactory from the standpoint of accuracy and processing time. (author)

  7. Lagrange polynomial interpolation method applied in the calculation of the J(ξ,β) function

    International Nuclear Information System (INIS)

    Fraga, Vinicius Munhoz; Palma, Daniel Artur Pinheiro; Martinez, Aquilino Senra

    2008-01-01

    The explicit dependence of the Doppler broadening function creates difficulties in the obtaining an analytical expression for J function . The objective of this paper is to present a method for the quick and accurate calculation of J function based on the recent advances in the calculation of the Doppler broadening function and on a systematic analysis of its integrand. The methodology proposed, of a semi-analytical nature, uses the Lagrange polynomial interpolation method and the Frobenius formulation in the calculation of Doppler broadening function . The results have proven satisfactory from the standpoint of accuracy and processing time. (author)

  8. SOLAR WIND STRAHL BROADENING BY SELF-GENERATED PLASMA WAVES

    Energy Technology Data Exchange (ETDEWEB)

    Pavan, J.; Gaelzer, R. [UFPEL, Pelotas (Brazil); Vinas, A. F. [NASA GSFC, Greenbelt, MD 20771 (United States); Yoon, P. H. [IPST, UMD, College Park, MD (United States); Ziebell, L. F., E-mail: joel.pavan@ufpel.edu.br, E-mail: rudi@ufpel.edu.br, E-mail: adolfo.vinas@nasa.gov, E-mail: yoonp@umd.edu, E-mail: luiz.ziebell@ufrgs.br [UFRGS, Porto Alegre (Brazil)

    2013-06-01

    This Letter reports on the results of numerical simulations which may provide a possible explanation for the strahl broadening during quiet solar conditions. The relevant processes involved in the broadening are due to kinetic quasi-linear wave-particle interaction. Making use of static analytical electron distribution in an inhomogeneous field, it is found that self-generated electrostatic waves at the plasma frequency, i.e., Langmuir waves, are capable of scattering the strahl component, resulting in energy and pitch-angle diffusion that broadens its velocity distribution significantly. The present theoretical results provide an alternative or complementary explanation to the usual whistler diffusion scenario, suggesting that self-induced electrostatic waves at the plasma frequency might play a key role in broadening the solar wind strahl during quiet solar conditions.

  9. Line broadening mechanisms of the orth-H2 pair spectrum

    International Nuclear Information System (INIS)

    Statt, B.W.; Hardy, W.N.

    1980-01-01

    Three broadening mechanisms for the ortho pair spectrum in solid hydrogen are investigated. First, theoretical predictions of the phonon induced lifetime broadening are presented. Next a theory is developed which gives the inhomogeneous broadening due to the presence of ortho molecules surrounding the pairs. An unexpected result is that certain lines remain unbroadened, at least to within the approximation made. Strain effects due to isotopic mass defect impurities are also considered. These predictions are then compared with experimental results. No temperature dependence of the lineshapes is observed, setting an upper limit on the phonon broadening contribution to the linewidth. This limit is an order of magnitude lower than the theory predicts. The predictions of the ortho broadening theory, on the other hand, are in good agreement with experiment. Samples doped with isotopic impurities are also investigated. (auth)

  10. Color doppler imaging of subclavian steal phenomenon

    International Nuclear Information System (INIS)

    Cho, Nari Ya; Chung, Tae Sub; Kim, Jai Keun

    1997-01-01

    To evaluate the characteristic color doppler imaging of vertebral artery flow in the subclavian steal phenomenon. The study group consisted of eight patients with reversed vertebral artery flow proved by color Doppler imaging. We classified this flow into two groups:(1) complete reversal;(2) partial reversal, as shown by Doppler velocity waveform. Vertebral angiography was performed in six of eight patients;color Doppler imaging and angiographic findings were compared. On color Doppler imaging, all eight cases with reversed vertebral artery flow showed no signal at the proximal subclavian or brachiocephalic artery. We confirmed shunting of six cases by performing angiography from the contralateral vertebral and basilar artery to the ipsilateral vertebral artery. On the Doppler spectrum, six cases showed complete reversal and two partial reversal. On angiography, one partial reversal case showed complete occlusion of the subclavian artery with abundant collateral circulation of muscular branches of the vertebral artery. On color Doppler imaging, a reversed vertebral artery suggests the subclavian steal phenomenon. In particular, partial reversal waveform may reflect collateral circulation

  11. FANAC - a shape analysis program for resonance parameter extraction from neutron capture data for light and medium-weight nuclei

    International Nuclear Information System (INIS)

    Froehner, F.H.

    1977-11-01

    A least-squares shape analysis program is described which is used at the Karlsruhe Nuclear Research Center for the extraction of resonance parameters from high-resolution capture data. The FORTRAN program was written for light to medium-weight or near-magic target nuclei whose cross sections are characterized on one hand by broad s-wave levels with negligible Doppler broadening but pronounced multi-level interference, on the other hand by narrow p-, d- ... wave resonances with negligible multi-level interference but pronounced Doppler broadening. Accordingly the Reich-Moore multi-level formalism without Doppler broadening is used for s-wave levels, and a single-level description with Doppler braodening for p-, d- ... wave levels. Calculated capture yields are resolution broadened. Multiple-collision events are simulated by Monte Carlo techniques. Up to five different time-of-flight capture data sets can be fitted simultaneously for samples containing up to ten isotopes. Input and output examples are given and a FORTRAN list is appended. (orig.)

  12. Radar micro-doppler signatures processing and applications

    CERN Document Server

    Chen, Victor C; Miceli, William J

    2014-01-01

    Radar Micro-Doppler Signatures: Processing and applications concentrates on the processing and application of radar micro-Doppler signatures in real world situations, providing readers with a good working knowledge on a variety of applications of radar micro-Doppler signatures.

  13. Color doppler sonography in thickened gallbladder wall

    International Nuclear Information System (INIS)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki

    1996-01-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes

  14. Excitation dependence of resonance line self-broadening at different atomic densities

    OpenAIRE

    Li, Hebin; Sautenkov, Vladimir A.; Rostovtsev, Yuri V.; Scully, Marlan O.

    2009-01-01

    We study the dipole-dipole spectral broadening of a resonance line at high atomic densities when the self-broadening dominates. The selective reflection spectrum of a weak probe beam from the interface of the cell window and rubidium vapor are recorded in the presence of a far-detuned pump beam. The excitation due to the pump reduces the self-broadening. We found that the self-broadening reduction dependence on the pump power is atomic density independent. These results provide experimental e...

  15. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  16. Measurements of ion temperature and flow of pulsed plasmas produced by a magnetized coaxial plasma gun device using an ion Doppler spectrometer

    Science.gov (United States)

    Kitagawa, Y.; Sakuma, I.; Iwamoto, D.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.

    2012-10-01

    It is important to know surface damage characteristics of plasma-facing component materials during transient heat and particle loads such as type I ELMs. A magnetized coaxial plasma gun (MCPG) device has been used as transient heat and particle source in ELM simulation experiments. Characteristics of pulsed plasmas produced by the MCPG device play an important role for the plasma material interaction. In this study, ion temperature and flow velocity of pulsed He plasmas were measured by an ion Doppler spectrometer (IDS). The IDS system consists of a light collection system including optical fibers, 1m-spectrometer and a 16 channel photomultiplier tube (PMT) detector. The IDS system measures the width and Doppler shift of HeII (468.58 nm) emission line with the time resolution of 1 μs. The Doppler broadened and shifted spectra were measured with 45 and 135 degree angles with respect to the plasmoid traveling direction. The observed emission line profile was represented by sum of two Gaussian components to determine the temperature and flow velocity. The minor component at around the wavelength of zero-velocity was produced by the stationary plasma. As the results, the ion velocity and temperature were 68 km/s and 19 eV, respectively. Thus, the He ion flow energy is 97 eV. The observed flow velocity agrees with that measured by a time of flight technique.

  17. The medical Doppler in hand surgery: its scientific basis, applications, and the history of its namesake, Christian Johann Doppler.

    Science.gov (United States)

    Ghori, Ahmer K; Chung, Kevin C

    2007-12-01

    The word Doppler is used synonymously in hand surgery for evaluating patency of vascular structures; however, the science and history behind the Doppler effect are not as well-known. We will present the theories behind the Doppler effect and the history of the person who made this discovery.

  18. Broadening nanotechnology's impact on development

    NARCIS (Netherlands)

    Beumer, K.

    2016-01-01

    Discussions about nanotechnology and development focus on applications that directly address the needs of the world’s poor. Nanotechnology can certainly make an impact in the fight against global poverty, but we need to broaden our imagination.

  19. Noncoherent Doppler tracking: first flight results

    Science.gov (United States)

    DeBoy, Christopher C.; Robert Jensen, J.; Asher, Mark S.

    2005-01-01

    Noncoherent Doppler tracking has been devised as a means to achieve highly accurate, two-way Doppler measurements with a simple, transceiver-based communications system. This technique has been flown as an experiment on the Thermosphere, Ionosphere, Mesosphere, Energetics and Dynamics (TIMED) spacecraft, (launched 7 December 2001), as the operational technique for Doppler tracking on CONTOUR, and is baselined on several future deep space missions at JHU/APL. This paper reports on initial results from a series of successful tests of this technique between the TIMED spacecraft and NASA ground stations in the Deep Space Network. It also examines the advantages that noncoherent Doppler tracking and a transceiver-based system may offer to small satellite systems, including reduced cost, mass, and power.

  20. Development of a Simple Positron Age-Momentum Setup

    Science.gov (United States)

    Sheffield, Thomas; Quarles, C. A.

    2009-04-01

    A positron age-momentum setup that uses NIM Bin electronic modules and a conventional multichannel analyzer (MCA) is described. The essential idea is to accumulate a Doppler broadened spectrum (sensitive to the annihilation electron momentum) using a high purity Germanium detector in coincidence with a BaF2 scintillation counter, which also serves as the stop signal in a conventional positron lifetime setup. The MCA that collects the Doppler spectrum is gated by a selected region of the lifetime spectrum. Thus we can obtain Doppler broadening spectra as a function of positron lifetime: an age-momentum spectrum. The apparatus has been used so far to investigate a ZnO sample where the size of different vacancy trapping sites may affect the positron lifetime and the Doppler broadening spectrum. We are also looking at polymer and rubber carbon-black composite samples where differences in the Doppler spectrum may arise from positron trapping or positronium formation in the samples. Correction for background and contribution from the positron source itself to the Doppler spectrum will be discussed.

  1. Anomalous Doppler effects in bulk phononic crystal

    International Nuclear Information System (INIS)

    Cai Feiyan; He Zhaojian; Zhang Anqi; Ding Yiqun; Liu Zhengyou

    2010-01-01

    Doppler effects in simple cubic phononic crystal are studied theoretically and numerically. In addition to observing Doppler shifts from a moving source's frequencies inside the gap, we find that Doppler shifts can be multi-order, anisotropic, and the dominant order of shift depends on the band index that the source's frequency is in.

  2. Two-quantum Doppler-free induced gamma emission

    International Nuclear Information System (INIS)

    Zadernovsky, A.A.

    1999-01-01

    Reported here is a theoretical study of an alternative way to remove the pernicious influence of chaotic motion of free nuclei by means of external ignition of two-quantum IGE process in counter-propagating intense photon beams. The performed analysis reveals the main advantages and drawbacks of this method. The following conclusions are underlined: 1. in contrast to single-quantum emission in an ensemble of nuclei with Doppler-broadened gain line, this method involves all nuclei regardless of there individual velocities; 2. a specific dynamic distributed feedback is in this case established in absence of any reflecting structures; 3. because of non-linearity of the feedback, with a coefficient proportional to the photon flux density of the igniting beam, the excitation of nuclei is released in an avalanche-like manner, which result in emission of a giant pulse of gamma quanta; 4. at present, the implementation of such a process is impeded by the absence of a source of igniting gamma quanta, with the sufficient photon flux density. Therefore the advantage of the propose technique may manifests themselves only in designing a final stage of a source of gamma quanta (e.g., in X-ray or gamma-ray laser, relativistic undulator, free electron laser, etc.) for production of short giant pulse of coherent gamma photons. (author)

  3. Estimating the Doppler centroid of SAR data

    DEFF Research Database (Denmark)

    Madsen, Søren Nørvang

    1989-01-01

    attractive properties. An evaluation based on an existing SEASAT processor is reported. The time-domain algorithms are shown to be extremely efficient with respect to requirements on calculations and memory, and hence they are well suited to real-time systems where the Doppler estimation is based on raw SAR......After reviewing frequency-domain techniques for estimating the Doppler centroid of synthetic-aperture radar (SAR) data, the author describes a time-domain method and highlights its advantages. In particular, a nonlinear time-domain algorithm called the sign-Doppler estimator (SDE) is shown to have...... data. For offline processors where the Doppler estimation is performed on processed data, which removes the problem of partial coverage of bright targets, the ΔE estimator and the CDE (correlation Doppler estimator) algorithm give similar performance. However, for nonhomogeneous scenes it is found...

  4. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were used....... On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA......) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. RESULTS...

  5. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The TCSP ER-2 DOPPLER RADAR (EDOP) dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of the ER-2...

  6. CAMEX-4 ER-2 DOPPLER RADAR V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-4 ER-2 Doppler Radar dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of ER-2. The...

  7. Trace isotope analysis using resonance ionization mass spectrometry based on isotope selection with doppler shift of laser ablated atoms

    International Nuclear Information System (INIS)

    Higuchi, Yuki; Watanabe, Kenichi; Kawarabayashi, Jun; Iguchi, Tetsuo

    2005-01-01

    We have proposed a novel isotope selective Resonance Ionization Mass Spectroscopy (RIMS) concept, which can avoid the Doppler broadening on solid sample direct measurement based on laser ablation technique. We have succeeded in experimentally demonstrating the principle of our RIMS concept. Through comparison between the simulated and experimental results, we have validated the simulation model. It would be concluded from these results that we could achieve the isotope selectivity defined as the ratio of 41 Ca to 40 Ca sensitivity to be 4.5x10 10 by adopting the multi-step excitation scheme in the present method. As future works, we will try to experimentally perform the multi-step excitation scheme and improve the detection efficiency by modifying the ion extraction configuration. (author)

  8. Direct Doppler auscultation of the carotid arteries

    International Nuclear Information System (INIS)

    Nix, L.

    1984-01-01

    The results of the carotid Doppler examinations and contrast arteriograms are presented. The overall sensitivity of the carotid Doppler examinations in detecting severe stenosis or occlusion of the carotid artery was 92%. The Doppler studies correctly differentiated these two conditions in 84% of the diseased vessels. In carotid arteries with stenosis greater than or equal to 50%, the sensitivity of the Doppler examinations was 90%, and these studies suggested stenosis in all but two of the 36 abnormal examinations. In two patent carotids with greater than 90% stenosis, a signal could not be elicited, presumably because of the low blood flow through the severely stenotic segment

  9. Accurate determination of the Boltzmann constant by Doppler spectroscopy: Towards a new definition of the kelvin

    International Nuclear Information System (INIS)

    Darquie, B.; Mejri, S.; Sow, P. L. T.; Lemarchand, C.; Triki, M.; Tokunaga, S. K.; Borde, C. J.; Chardonnet, C.; Daussy, C.

    2013-01-01

    Accurate molecular spectroscopy in the mid-infrared region allows precision measurements of fundamental constants. For instance, measuring the linewidth of an isolated Doppler-broadened absorption line of ammonia around 10 μm enables a determination of the Boltzmann constant k B . We report on our latest measurements. By fitting this lineshape to several models which include Dicke narrowing or speed-dependent collisional effects, we find that a determination of k B with an uncertainty of a few ppm is reachable. This is comparable to the best current uncertainty obtained using acoustic methods and would make a significant contribution to any new value of k B determined by the CODATA. Furthermore, having multiple independent measurements at these accuracies opens the possibility of defining the kelvin by fixing k B , an exciting prospect considering the upcoming redefinition of the International System of Units. (authors)

  10. Recommendations for terminology and display for doppler echocardiography

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Doppler echocardiography has recently emerged as a major noninvasive technique with many applications in cardiology. To a large extent, this has been based upon a combination of clinical and engineering advances which now make possible the use of quantitative Doppler echocardiography in combination with two-dimensional imaging for measurement of volume flows, transvalve gradients, and other physiologic flow parameters which reflect cardiac function. It was the purpose of this Committee to provide a glossary of terms which could be used in standard fashion for papers and discussions related to Doppler echocardiography. As part of its task, the Committee also undertook an attempt to recommend a standard for display of Doppler information which would be useful, both for manufacturers and for clinicians. The document, therefore, includes: Section I, the Committee's recommendations for Doppler display. Section II, the glossary of Doppler terms, related to engineering and to clinical applications

  11. High-Frame-Rate Power Doppler Ultrasound Is More Sensitive than Conventional Power Doppler in Detecting Rheumatic Vascularisation

    NARCIS (Netherlands)

    M. van der Ven (Myrthe); J.J. Luime (Jolanda); van der Velden, L.L. (Levinia L.); J.G. Bosch (Hans); J.M.W. Hazes (Mieke); H.J. Vos (Rik)

    2016-01-01

    textabstractEarly recognition of joint inflammation will increase treatment efficacy in rheumatoid arthritis (RA). Yet, conventional power Doppler (PD) ultrasound might not be sufficiently sensitive to detect minor inflammation. We investigated the sensitivity of high-frame rate Doppler, combined

  12. Power doppler 'blanching' after the application of transducer pressure

    International Nuclear Information System (INIS)

    Joshua, F.; Edmonds, J.; Lassere, M.; De Carle, R.; Rayment, M.; Bryant, C.; Shnier, R.

    2005-01-01

    The aim of this study was to determine if transducer pressure modifies power Doppler assessments of rheumatoid arthritis synovium at the metacarpophalangeal joints and metatarsophalangeal joints. Five rheumatoid arthritis patients of varying degrees of 'disease activity' and damage were assessed with power Doppler ultrasound scanning of the dominant hand second to fifth metacarpophalangeal joints. Two rheumatoid arthritis patients had their dominant foot first to fifth metatarsophalangeal joints assessed with power Doppler ultrasound. Ultrasonography was performed with a high frequency transducer (14 MHz) with a colour mode frequency of 10 Mhz, and a standard colour box and gain. In the joint that showed the highest power Doppler signal, an image was made. A further image was taken after transducer pressure was applied. In all patients, there was increased flow to at least one joint. After pressure was applied, power Doppler signal intensity markedly reduced in all images and in some there was no recordable power Doppler signal. Increased transducer pressure can result in a marked reduction or obliteration in power Doppler signal. This power Doppler 'blanching' shows the need for further studies to evaluate sources of error and standardization before power Doppler ultrasound becomes a routine measure of 'disease activity' in rheumatoid arthritis. Copyright (2005) Blackwell Science Pty Ltd

  13. Development of the doppler electron velocimeter: theory.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.

    2007-03-01

    Measurement of dynamic events at the nano-scale is currently impossible. This paper presents the theoretical underpinnings of a method for making these measurements using electron microscopes. Building on the work of Moellenstedt and Lichte who demonstrated Doppler shifting of an electron beam with a moving electron mirror, further work is proposed to perfect and utilize this concept in dynamic measurements. Specifically, using the concept of ''fringe-counting'' with the current principles of transmission electron holography, an extension of these methods to dynamic measurements is proposed. A presentation of the theory of Doppler electron wave shifting is given, starting from the development of the de Broglie wave, up through the equations describing interference effects and Doppler shifting in electron waves. A mathematical demonstration that Doppler shifting is identical to the conceptually easier to understand idea of counting moving fringes is given by analogy to optical interferometry. Finally, potential developmental experiments and uses of a Doppler electron microscope are discussed.

  14. Re-Normalization Method of Doppler Lidar Signal for Error Reduction

    Energy Technology Data Exchange (ETDEWEB)

    Park, Nakgyu; Baik, Sunghoon; Park, Seungkyu; Kim, Donglyul [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Dukhyeon [Hanbat National Univ., Daejeon (Korea, Republic of)

    2014-05-15

    In this paper, we presented a re-normalization method for the fluctuations of Doppler signals from the various noises mainly due to the frequency locking error for a Doppler lidar system. For the Doppler lidar system, we used an injection-seeded pulsed Nd:YAG laser as the transmitter and an iodine filter as the Doppler frequency discriminator. For the Doppler frequency shift measurement, the transmission ratio using the injection-seeded laser is locked to stabilize the frequency. If the frequency locking system is not perfect, the Doppler signal has some error due to the frequency locking error. The re-normalization process of the Doppler signals was performed to reduce this error using an additional laser beam to an Iodine cell. We confirmed that the renormalized Doppler signal shows the stable experimental data much more than that of the averaged Doppler signal using our calibration method, the reduced standard deviation was 4.838 Χ 10{sup -3}.

  15. Dependence of inhomogeneous vibrational linewidth broadening on attractive forces from local liquid number densities

    International Nuclear Information System (INIS)

    George, S.M.; Harris, C.B.

    1982-01-01

    The dependence of inhomogeneous vibrational linewidth broadening on attractive forces form slowly varying local liquid number densities is examined. The recently developed Schweizer--Chandler theory of vibrational dephasing is used to compute absolute inhomogeneous broadening linewidths. The computed linewidths are compared to measured inhomogeneous broadening linewidths determined using picosecond vibrational dephasing experiments. There is a similarity between correlations of the Schweizer--Chandler and George--Auweter--Harris predicted inhomogeneous broadening linewidths and the measured inhomogeneous broadening linewidths. For the methyl stretches under investigation, this correspondence suggests that the width of the number density distribution in the liquid determines the relative inhomogeneous broadening magnitudes

  16. Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?

    Directory of Open Access Journals (Sweden)

    Lawrence H. Lin

    Full Text Available Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: “Gestational trophoblastic disease AND Ultrasonography, Doppler.” Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1 Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2 There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3 Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4 Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. CONCLUSION: Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.

  17. Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?

    Science.gov (United States)

    Lin, Lawrence H; Bernardes, Lisandra S; Hase, Eliane A; Fushida, Koji; Francisco, Rossana P V

    2015-12-01

    Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: "Gestational trophoblastic disease AND Ultrasonography, Doppler." Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1) Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2) There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3) Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4) Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.

  18. Preliminary simulation study of doppler reflectometry

    International Nuclear Information System (INIS)

    Ishii, Yuta; Hojo, Hitoshi; Yoshikawa, Masashi; Ichimura, Makoto; Haraguchi, Yusuke; Imai, Tsuyoshi; Mase, Atsushi

    2010-01-01

    A preliminary simulation study of Doppler reflectometry is performed. The simulations solve Maxwell's equations by a finite difference time domain (FDTD) code method in two dimensions. A moving corrugated metal target is used as a plasma cutoff layer to study the basic features of Doppler reflectometry. We examined the effects of the full width at half maximum (FWHM) of the electromagnetic waves and the corrugation depth of the metal target. Furthermore, the effect of a nonuniform plasma is studied using this FDTD analysis. The Doppler shift and velocity are compared with those obtained from FDTD analysis of a uniform plasma. (author)

  19. Doppler speedometer for micro-organisms

    International Nuclear Information System (INIS)

    Penkov, F.; Tuleushev, A.; Lisitsyn, V.; Kim, S.; Tuleushev, Yu.

    1996-01-01

    Objective of Investigations: Development and creation of the Doppler speedometer for micro-organisms which allows to evaluate, in a real temporal scale, variations in the state of water suspension of micro-organisms under the effect of chemical, physical and other external actions. Statement of the Problem The main problem is absence of reliable, accessible for users and simple, in view of application, Doppler speedometers for micro-organisms. Nevertheless, correlation Doppler spectrometry in the regime of heterodyning the supporting and cell-scattered laser radiation is welt known. The main idea is that the correlation function of photo-current pulses bears an information on the averages over the assembly of cell velocities. For solving the biological problems, construction of auto-correlation function in the real-time regime with the delay time values comprising, function in the real-time regime with the delay time values comprising, nearly, 100 me (10 khz) or higher is needed. Computers of high class manage this problem using but the program software. Due to this, one can simplify applications of the proposed techniques provided he creates the Doppler speedometer for micro-organism on a base of the P entium . Expected Result Manufactured operable mock-up of the Doppler speedometer for micro-organisms in a form of the auxiliary computer block which allows to receive an information, in the real time scale, on the results of external effects of various nature on the cell assembly in transparent medium with a small volume of the studied cell suspension

  20. De-Dopplerization of Acoustic Measurements

    Science.gov (United States)

    2017-08-10

    accurate measurement of aircraft location to resample the time signal to account for the compression and expansion of acoustic wavefronts. Correcting...AFRL-RH-WP-TR-2017-0043 DE-DOPPLERIZATION OF ACOUSTIC MEASUREMENTS Frank Mobley, PhD 711 HPW/RHCB Wright-Patterson AFB OH...TITLE AND SUBTITLE DE-DOPPLERIZATION OF ACOUSTIC MEASUREMENTS 5a. CONTRACT NUMBER In-House 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER

  1. Beam broadening of polar molecules and clusters in deflection experiments.

    Science.gov (United States)

    Bulthuis, J; Kresin, V V

    2012-01-07

    A beam of rotating dipolar particles (molecules or clusters) will broaden when passed through an electric or magnetic field gradient region. This broadening, which is a common experimental observable, can be expressed in terms of the variance of the distribution of the resulting polarization orientation (the direction cosine). Here, the broadening for symmetric-top and linear rotors is discussed. These two types of rotors have qualitatively different low-field orientation distribution functions, but behave similarly in a strong field. While analytical expressions for the polarization variance can be derived from first-order perturbation theory, for experimental guidance it is important to identify the applicability and limitations of these expressions, and the general dependence of the broadening on the experimental parameters. For this purpose, the analytical results are compared with the full diagonalization of the rotational Stark-effect matrices. Conveniently for experimental estimations, it is found that for symmetric tops, the dependence of the broadening parameter on the rotational constant, the axial ratio, and the field strength remains similar to the analytical expression even outside of the perturbative regime. Also, it is observed that the shape envelope, the centroid, and the width of the orientation distribution function for a symmetric top are quite insensitive to the value of its rotational constant (except at low rotational temperatures).

  2. Doppler radar physiological sensing

    CERN Document Server

    Lubecke, Victor M; Droitcour, Amy D; Park, Byung-Kwon; Singh, Aditya

    2016-01-01

    Presents a comprehensive description of the theory and practical implementation of Doppler radar-based physiological monitoring. This book includes an overview of current physiological monitoring techniques and explains the fundamental technology used in remote non-contact monitoring methods. Basic radio wave propagation and radar principles are introduced along with the fundamentals of physiological motion and measurement. Specific design and implementation considerations for physiological monitoring radar systems are then discussed in detail. The authors address current research and commercial development of Doppler radar based physiological monitoring for healthcare and other applications.

  3. The phenomenon of Doppler

    International Nuclear Information System (INIS)

    Stoll, I.; Seidlerova, I.; Schwippel, J.; Poss, O.; Solc, M.

    1992-01-01

    The book is devoted to the life and work of Christian Doppler and particularly to his links to Prague and to the Slovak town of Banska Stiavnica. Many historical facts concerning Doppler's activities as well as the history of physics and astronomy are collected. Information is also presented about the Czech Technical University, the Society of Czechoslovak Mathematicians and Physicists, the Czechoslovak Astronomical Society, the Czechoslovak Spectroscopic Society and the Czechoslovak Society for the History of Science and Technology. The publication is amply supplemented with historical pictorial material (M.D.). 92 figs., 82 refs

  4. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Maulik, D.

    2005-01-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  5. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Maulik, D. [Winthrop Univ. Hospital, Mineola, NY (United States). Dept. of Obstetrics and Gynecology; Zalud, I. (eds.) [Kapiolani Medical Center for Women and Children, Honolulu, HI (United States)

    2005-07-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  6. Water absorption lines, 931-961 nm - Selected intensities, N2-collision-broadening coefficients, self-broadening coefficients, and pressure shifts in air

    Science.gov (United States)

    Giver, L. P.; Gentry, B.; Schwemmer, G.; Wilkerson, T. D.

    1982-01-01

    Intensities were measured for 97 lines of H2O vapor between 932 and 961 nm. The lines were selected for their potential usefulness for remote laser measurements of H2O vapor in the earth's atmosphere. The spectra were obtained with several different H2O vapor abundances and N2 broadening gas pressures; the spectral resolution was 0.046/cm FWHM. Measured H2O line intensities range from 7 x 10 to the -25th to 7 x 10 to the -22nd/cm per (molecules/sq cm). H2O self-broadening coefficients were measured for 13 of these strongest lines; the mean value was 0.5/cm per atm. N2-collision-broadening coefficients were measured for 73 lines, and the average was 0.11 cm per atm HWHM. Pressure shifts in air were determined for a sample of six lines between 948 and 950 nm; these lines shift to lower frequency by an amount comparable to 0.1 of the collision-broadened widths measured in air or N2. The measured intensities of many lines of 300-000 band are much larger than expected from prior computations, in some cases by over an order of magnitude. Coriolis interactions with the stronger 201-000 band appear to be the primary cause of the enhancement of these line intensities.

  7. Lifetimes in neutron-rich Nd isotopes measured by Doppler profile method

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, I.; Lister, C.J.; Morss, L.R. [and others

    1995-08-01

    Lifetimes of the rotational levels in neutron-rich even-even Nd isotopes were deduced from the analysis of the Doppler broadened line shapes. The experiment was performed at Daresbury with the Eurogam array, which at that time consisted of 45 Compton-suppressed Ge detectors and 5 Low-Energy Photon Spectrometers. The source was in the form of a 7-mm pellet which was prepared by mixing 5-mg; {sup 248}Cm and 65-mg KCl and pressing it under high pressure. Events for which three or more detectors fired were used to construct a cubic data array whose axes represented the {gamma}-ray energies and the contents of each channel the number of events with that particular combination of {gamma}-ray energies. From this cubic array, one-dimensional spectra were generated by placing gates on peaks on the other two axes. Gamma-ray spectra of even-even Nd isotopes were obtained by gating on the transitions in the complimentary Kr fragments. The gamma peaks de-exciting states with I {>=} 12 h were found to be broader than the instrumental line width due to the Doppler effect. The line shapes of they-ray peaks were fitted separately with a simple model for the feeding of the states and assuming a rotational band with constant intrinsic quadruple moment and these are shown in Fig. I-27. The quadrupole moments thus determined were found to be in good agreement with the quadrupole moments measured previously for lower spin states. Because of the success of this technique for the Nd isotopes, we intend to apply this technique to the new larger data set collected with the Eurogam II array. The results of this study were published.

  8. New Insights from Inside-Out Doppler Tomography

    Directory of Open Access Journals (Sweden)

    E. J. Kotze

    2015-02-01

    Full Text Available We present preliminary results from our investigation into using an “inside-out” velocity space for creating a Doppler tomogram. The aim is to transpose the inverted appearance of the Cartesian velocity space used in normal Doppler tomography. In a comparison between normal and inside-out Doppler tomograms of cataclysmic variables, we show that the inside-out velocity space has the potential to produce new insights into the accretion dynamics in these systems.

  9. Measurement of ventricular function using Doppler ultrasound

    International Nuclear Information System (INIS)

    Teague, S.M.

    1986-01-01

    Doppler has wide application in the evaluation of valvular heart disease. The need to know ventricular function is a much more common reason for an echocardiographic evaluation. Interestingly, Doppler examinations can assess ventricular function from many perspectives. Description of ventricular function entails measurement of the timing, rate and volume of ventricular filling and ejection. Doppler ultrasound examination reveals all of these aspects of ventricular function noninvasively, simply, and without great expense or radiation exposure, as described in this chapter

  10. MP3 compression of Doppler ultrasound signals.

    Science.gov (United States)

    Poepping, Tamie L; Gill, Jeremy; Fenster, Aaron; Holdsworth, David W

    2003-01-01

    The effect of lossy, MP3 compression on spectral parameters derived from Doppler ultrasound (US) signals was investigated. Compression was tested on signals acquired from two sources: 1. phase quadrature and 2. stereo audio directional output. A total of 11, 10-s acquisitions of Doppler US signal were collected from each source at three sites in a flow phantom. Doppler signals were digitized at 44.1 kHz and compressed using four grades of MP3 compression (in kilobits per second, kbps; compression ratios in brackets): 1400 kbps (uncompressed), 128 kbps (11:1), 64 kbps (22:1) and 32 kbps (44:1). Doppler spectra were characterized by peak velocity, mean velocity, spectral width, integrated power and ratio of spectral power between negative and positive velocities. The results suggest that MP3 compression on digital Doppler US signals is feasible at 128 kbps, with a resulting 11:1 compression ratio, without compromising clinically relevant information. Higher compression ratios led to significant differences for both signal sources when compared with the uncompressed signals. Copyright 2003 World Federation for Ultrasound in Medicine & Biology

  11. Hydrogen Balmer Line Broadening in Solar and Stellar Flares

    Energy Technology Data Exchange (ETDEWEB)

    Kowalski, Adam F. [Department of Astrophysical and Planetary Sciences, University of Colorado Boulder, 2000 Colorado Avenue, Boulder, CO 80305 (United States); Allred, Joel C. [NASA/Goddard Space Flight Center, Code 671, Greenbelt, MD 20771 (United States); Uitenbroek, Han [National Solar Observatory, University of Colorado Boulder, 3665 Discovery Drive, Boulder, CO 80303 (United States); Tremblay, Pier-Emmanuel [Department of Physics, University of Warwick, Coventry CV47AL (United Kingdom); Brown, Stephen [School of Physics and Astronomy, Kelvin Building, University of Glasgow, G12 8QQ (United Kingdom); Carlsson, Mats [Institute of Theoretical Astrophysics, University of Oslo, P.O. Box 1029 Blindern, NO-0315 Oslo (Norway); Osten, Rachel A. [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Wisniewski, John P. [Homer L. Dodge Department of Physics and Astronomy, University of Oklahoma, 440 W. Brooks Street, Norman, OK 73019 (United States); Hawley, Suzanne L., E-mail: Adam.Kowalski@lasp.colorado.edu [University of Washington Department of Astronomy, 3910 15th Avenue NE, Seattle, WA 98195 (United States)

    2017-03-10

    The broadening of the hydrogen lines during flares is thought to result from increased charge (electron, proton) density in the flare chromosphere. However, disagreements between theory and modeling prescriptions have precluded an accurate diagnostic of the degree of ionization and compression resulting from flare heating in the chromosphere. To resolve this issue, we have incorporated the unified theory of electric pressure broadening of the hydrogen lines into the non-LTE radiative-transfer code RH. This broadening prescription produces a much more realistic spectrum of the quiescent, A0 star Vega compared to the analytic approximations used as a damping parameter in the Voigt profiles. We test recent radiative-hydrodynamic (RHD) simulations of the atmospheric response to high nonthermal electron beam fluxes with the new broadening prescription and find that the Balmer lines are overbroadened at the densest times in the simulations. Adding many simultaneously heated and cooling model loops as a “multithread” model improves the agreement with the observations. We revisit the three-component phenomenological flare model of the YZ CMi Megaflare using recent and new RHD models. The evolution of the broadening, line flux ratios, and continuum flux ratios are well-reproduced by a multithread model with high-flux nonthermal electron beam heating, an extended decay phase model, and a “hot spot” atmosphere heated by an ultrarelativistic electron beam with reasonable filling factors: ∼0.1%, 1%, and 0.1% of the visible stellar hemisphere, respectively. The new modeling motivates future work to understand the origin of the extended gradual phase emission.

  12. Hydrogen Balmer Line Broadening in Solar and Stellar Flares

    International Nuclear Information System (INIS)

    Kowalski, Adam F.; Allred, Joel C.; Uitenbroek, Han; Tremblay, Pier-Emmanuel; Brown, Stephen; Carlsson, Mats; Osten, Rachel A.; Wisniewski, John P.; Hawley, Suzanne L.

    2017-01-01

    The broadening of the hydrogen lines during flares is thought to result from increased charge (electron, proton) density in the flare chromosphere. However, disagreements between theory and modeling prescriptions have precluded an accurate diagnostic of the degree of ionization and compression resulting from flare heating in the chromosphere. To resolve this issue, we have incorporated the unified theory of electric pressure broadening of the hydrogen lines into the non-LTE radiative-transfer code RH. This broadening prescription produces a much more realistic spectrum of the quiescent, A0 star Vega compared to the analytic approximations used as a damping parameter in the Voigt profiles. We test recent radiative-hydrodynamic (RHD) simulations of the atmospheric response to high nonthermal electron beam fluxes with the new broadening prescription and find that the Balmer lines are overbroadened at the densest times in the simulations. Adding many simultaneously heated and cooling model loops as a “multithread” model improves the agreement with the observations. We revisit the three-component phenomenological flare model of the YZ CMi Megaflare using recent and new RHD models. The evolution of the broadening, line flux ratios, and continuum flux ratios are well-reproduced by a multithread model with high-flux nonthermal electron beam heating, an extended decay phase model, and a “hot spot” atmosphere heated by an ultrarelativistic electron beam with reasonable filling factors: ∼0.1%, 1%, and 0.1% of the visible stellar hemisphere, respectively. The new modeling motivates future work to understand the origin of the extended gradual phase emission.

  13. Broadening the spectrum through curriculum

    International Nuclear Information System (INIS)

    Engel-Hills P

    2006-01-01

    Radiography has experienced changes and challenges from a number of sources. The rapid technological changes in imaging an radiation treatment, changes in the professional context and social transformation have had an impact on the shape and structure of the radiography curriculum. It too must change to prepare graduates for the broadening radiography spectrum

  14. Analysis of Doppler effect with JAERI-Fast set

    International Nuclear Information System (INIS)

    Takano, Hideki; Matsui, Yasushi.

    1977-07-01

    Temperature dependence of group cross sections in the JAERI-Fast set versions I, IR, II and IIR has been tested from the analysis of Doppler experiments performed with two different methods. One is Doppler reactivity measurement for the whole core of SEFOR assembly, and the other sample Doppler reactivity measurement for natural UO 2 in FCA assemblies V-1, V-2, VI-1 and VI-2, ZPR-6-7, ZPR-3-47, and ZPPR-2 and 3. Doppler effects were calculated with one- and two-dimensional diffusion 1-st order perturbation code DOPP2D. The results calculated with the JAERI-Fast set versions II and IIR are in good agreement with the experimental ones. In these calculation, resonance heterogeneity effect, stainless-stell buffer effect and plate heterogeneity effect are considered, and these effects contribute significantly to Doppler effect. (auth.)

  15. Doppler ion program description

    International Nuclear Information System (INIS)

    Henline, P.

    1980-12-01

    The Doppler spectrometer is a conventional Czerny-Turner grating spectrometer with a 1024 channel multiple detector. Light is dispersed across the detector, and its output yields a spectrum covering approximately 200 A. The width of the spectral peak is directly proportional to the temperature of the emitting ions, and determination of the impurity ion temperature allows one to infer the plasma ion temperature. The Doppler ion software system developed at General Atomic uses a TRACOR Northern 1710-31 and an LSI-11/2. The exact configuration of Doublet III is different from TRACOR Northern systems at other facilities

  16. High-T/sub c/ superconductor YBa2Cu3O/sub 7-//sub δ/ studied by positron annihilation

    International Nuclear Information System (INIS)

    Wang, S.J.; Naidu, S.V.; Sharma, S.C.; De, D.K.; Jeong, D.Y.; Black, T.D.; Krichene, S.; Reynolds, J.R.; Owens, J.M.

    1988-01-01

    We have measured the positron lifetime and the Doppler broadening spectra in the high-temperature superconductor YBa 2 Cu 3 O/sub 7-//sub δ/ as a function of temperature between 77 and 295 K. Positron-lifetime and Doppler-broadening data show new features in the superconducting phase. These results are interpreted in terms of positron localization in lattice distortions and positron surface states

  17. Complex regression Doppler optical coherence tomography

    Science.gov (United States)

    Elahi, Sahar; Gu, Shi; Thrane, Lars; Rollins, Andrew M.; Jenkins, Michael W.

    2018-04-01

    We introduce a new method to measure Doppler shifts more accurately and extend the dynamic range of Doppler optical coherence tomography (OCT). The two-point estimate of the conventional Doppler method is replaced with a regression that is applied to high-density B-scans in polar coordinates. We built a high-speed OCT system using a 1.68-MHz Fourier domain mode locked laser to acquire high-density B-scans (16,000 A-lines) at high enough frame rates (˜100 fps) to accurately capture the dynamics of the beating embryonic heart. Flow phantom experiments confirm that the complex regression lowers the minimum detectable velocity from 12.25 mm / s to 374 μm / s, whereas the maximum velocity of 400 mm / s is measured without phase wrapping. Complex regression Doppler OCT also demonstrates higher accuracy and precision compared with the conventional method, particularly when signal-to-noise ratio is low. The extended dynamic range allows monitoring of blood flow over several stages of development in embryos without adjusting the imaging parameters. In addition, applying complex averaging recovers hidden features in structural images.

  18. Cross-correlation Doppler global velocimetry (CC-DGV)

    Science.gov (United States)

    Cadel, Daniel R.; Lowe, K. Todd

    2015-08-01

    A flow velocimetry method, cross-correlation Doppler global velocimetry (CC-DGV), is presented as a robust, simplified, and high dynamic range implementation of the Doppler global/planar Doppler velocimetry technique. A sweep of several gigahertz of the vapor absorption spectrum is used for each velocity sample, with signals acquired from both Doppler-shifted scattered light within the flow and a non-Doppler shifted reference beam. Cross-correlation of these signals yields the Doppler shift between them, averaged over the duration of the scan. With presently available equipment, velocities from 0 ms-1 to over 3000 ms-1 can notionally be measured simultaneously, making the technique ideal for high speed flows. The processing routine is shown to be robust against large changes in the vapor pressure of the iodine cell, benefiting performance of the system in facilities where ambient conditions cannot be easily regulated. Validation of the system was performed with measurements of a model wind turbine blade boundary layer made in a 1.83 m by 1.83 m subsonic wind tunnel for which laser Doppler velocimetry (LDV) measurements were acquired alongside the CC-DGV results. CC-DGV uncertainties of ±1.30 ms-1, ±0.64 ms-1, and ±1.11 ms-1 were determined for the orthogonal stream-wise, transverse-horizontal, and transverse-vertical velocity components, and root-mean-square deviations of 2.77 ms-1 and 1.34 ms-1 from the LDV validation results were observed for Reynolds numbers of 1.5 million and 2 million, respectively. Volumetric mean velocity measurements are also presented for a supersonic jet, with velocity uncertainties of ±4.48 ms-1, ±16.93 ms-1, and ±0.50 ms-1 for the orthogonal components, and self-validation done by collapsing the data with a physical scaling.

  19. Editorial special issue on "Laser Doppler vibrometry"

    Science.gov (United States)

    Vanlanduit, Steve; Dirckx, Joris

    2017-12-01

    The invention of the laser in 1960 has opened up many opportunities in the field of measurement science and technology. Just a few years after the invention of the laser, a novel fluid flow measurement technique based on the Doppler effect was introduced: at that moment the laser Doppler anemometer or shortly LDA [1] was born. The technique enabled fluid velocity measurement by using the light of a He-Ne beam which was scattered by very small polystyrene spheres entrained in the fluid. Later on, in the late nineteen seventees it was recognized that the detection of the Doppler frequency shift that occurs when light is scattered by a moving surface can also be used to measure the vibration velocity of an object. The instrument to perform these vibration measurements was called the laser Doppler vibrometer or LDV [2]. In the last decades several technological advances were made in the field of laser Doppler vibrometry. The result is that nowadays, velocity measurements of fluids (using LDA) and vibrating objects (using LDV) are performed in many challenging applications in different fields (microelectronics, civil structures, biomedical engineering, material science, etc.).

  20. Quasi-particle lifetime broadening in normal-superconductor junctions with UPt3

    International Nuclear Information System (INIS)

    Wilde, T. de; Argonne National Lab., IL; Klapwijk, T.M.; Rijksuniversiteit Groningen; Rijksuniversiteit Groningen; Jansen, A.G.M.; Heil, J.; Wyder, P.

    1996-01-01

    For the Andreev-reflection process of quasi-particles at a normal-metal-superconductor interface the influence of lifetime broadening of the quasi-particles on the current-voltage characteristics of NS point contacts is analyzed along the lines of the Blonder-Tinkham-Klapwijk model. The anomalous Andreev-reflection spectra obtained for the heavy-fermion compound UPt 3 cannot be explained by lifetime broadening alone. Instead, an anisotropic superconducting order parameter has to be assumed which, if also lifetime broadening is included, leads to a fairly good agreement with the data. (orig.)

  1. Glare Spot Phase Doppler Anemometry

    OpenAIRE

    Hespel, Camille; Ren, Kuan Fang; Gréhan, Gérard; Onofri, Fabrice

    2006-01-01

    International audience; The Phase Doppler anemometry has been developed to measure simultaneously the velocity and the size of droplets. The measurement of the refractive index is also necessary since it depends on the temperature and the composition of the particle and its measurement permits both to increase the quality of the diameter measurement and to obtain information on the temperature and/or the composition of the droplets. In this paper, we introduce a Glare Spot Phase Doppler Anemo...

  2. Radar Doppler Processing with Nonuniform Sampling.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Conventional signal processing to estimate radar Doppler frequency often assumes uniform pulse/sample spacing. This is for the convenience of t he processing. More recent performance enhancements in processor capability allow optimally processing nonuniform pulse/sample spacing, thereby overcoming some of the baggage that attends uniform sampling, such as Doppler ambiguity and SNR losses due to sidelobe control measures.

  3. Doppler echocardiography in pediatric cardiology

    International Nuclear Information System (INIS)

    Allen, H.D.; Marx, G.R.

    1986-01-01

    Congenital heart disease encompasses abnormalities in cardiac development which generally have in common either valve stenoses or connections between chambers or great vessels. Usually, abnormalities of intracardiac anatomy, and often, abnormalities of great vessel anatomy, can be unraveled by two-dimensional echocardiography. However, echocardiography offers little information regarding flow characteristics in the various congenital lesions. Addition of the Doppler principle, particularly when combined with the two-dimensional examination, can characterize the source of a flow disturbance, quantify gradients across a site of obstruction, and quantify flow volume across sites where flow is nonturbulent. These features make Doppler echocardiography unique for noninvasive accurate evaluation of children and adults with various forms of congenital heart disease. In this report, the authors discuss some of the present uses of Doppler echocardiography in congenital heart disease. Application of this technique requires greater understanding of certain physics principles than does routine echocardiography

  4. Self-phase-modulation induced spectral broadening in silicon waveguides

    Science.gov (United States)

    Boyraz, Ozdal; Indukuri, Tejaswi; Jalali, Bahram

    2004-03-01

    The prospect for generating supercontinuum pulses on a silicon chip is studied. Using ~4ps optical pulses with 2.2GW/cm2 peak power, a 2 fold spectral broadening is obtained. Theoretical calculations, that include the effect of two-photon-absorption, indicate up to 5 times spectral broadening is achievable at 10x higher peak powers. Representing a nonlinear loss mechanism at high intensities, TPA limits the maximum optical bandwidth that can be generated.

  5. Doppler ultrasound scan during normal gestation: umbilical circulation; Ecografia Doppler en la gestacion normal: circulacion umbilical

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J. [Hospital Virgen Macarena. Sevilla (Spain)

    2002-07-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs.

  6. Broadening failure rate distributions in PRA uncertainty analyses

    International Nuclear Information System (INIS)

    Martz, H.F.

    1984-01-01

    Several recent nuclear power plant probabilistic risk assessments (PRAs) have utilized broadened Reactor Safety Study (RSS) component failure rate population variability curves to compensate for such things as expert overvaluation bias in the estimates upon which the curves are based. A simple two-components of variation empirical Bayes model is proposed for use in estimating the between-expert variability curve in the presence of such biases. Under certain conditions this curve is a population variability curve. Comparisons are made with the existing method. The popular procedure appears to be generally much more conservative than the empirical Bayes method in removing such biases. In one case the broadened curve based on the popular method is more than two orders of magnitude broader than the empirical Bayes curve. In another case it is found that the maximum justifiable degree of broadening of the RSS curve is to increase α from 5% to 12%, which is significantly less than 20% value recommended in the popular approach. 15 references, 1 figure, 5 tables

  7. Longitudinal study of aortic isthmus Doppler in appropriately grown and small-for-gestational-age fetuses with normal and abnormal umbilical artery Doppler.

    LENUS (Irish Health Repository)

    Kennelly, M M

    2012-04-01

    To establish reference ranges using longitudinal data for aortic isthmus (AoI) Doppler indices in appropriate-for-gestational-age (AGA) fetuses and to document the longitudinal trends in a cohort of small-for-gestational-age (SGA) fetuses with normal umbilical artery Doppler and in fetuses with intrauterine growth restriction (IUGR) and abnormal umbilical artery Doppler.

  8. Musculoskeletal colour/power Doppler in sports medicine

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, M; Langberg, Henning

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...

  9. Temporal enhancement of two-dimensional color doppler echocardiography

    Science.gov (United States)

    Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.

    2016-03-01

    Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.

  10. Doppler US evaluation of the hypertensive portal system

    International Nuclear Information System (INIS)

    Needleman, L.; Kurtz, A.B.; Bezzi, M.; Rifkin, M.D.; Pasto, M.E.; Pennell, R.G.; Baltarowich, O.H.; Goldberg, B.B.

    1986-01-01

    In patients with known portal hypertension, pulsed Doppler US was used for qualitative and directional evaluation of flow in the portal venous system and collateral vessels. Most patients had normal hepatopetal flow. Doppler US revealed the following abnormal blood flow patterns: hepatofugal portal flow, bidirectional portal flow, intrahepatic portal shunting, flow in portasystemic collaterals, and hepatic vein obstruction. Doppler US can provide important clinical information in the evaluation of portal hypertension

  11. The image of urachus adenocarcinoma on Doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Oyar, Orhan E-mail: o_oyar@hotmail.com; Yesildag, Ahmet; Gulsoy, Ufuk Kemal; Perk, Hakki

    2002-10-01

    Malignant urachal lesions are exceedingly rare and occur predominantly in adult life. In this case report, an adult patient with urachal carcinoma is presented with abdominal plain film, intravenous urography, gray-scale ultrasonography (US), Doppler US, and computed tomography (CT). Doppler US successfully showed the neovascularity with low resistive index value in the urachus tumor. We believe that Doppler US examination is helpful in the differential diagnosis of urachal carcinoma.

  12. Doppler coefficient measurements in Zebra Core 5

    International Nuclear Information System (INIS)

    Baker, A.R.; Wheeler, R.C.

    1965-11-01

    Measurements using a central hot loop in Zebra Core 5 are described. Results are given for the Doppler coefficients found in a number of assemblies with PuO 2 and 16% PuO 2 /84% depleted UO 2 pins, loaded with different combinations of steel, sodium or void pins. The mixed oxide results are in general about 20% more negative than was calculated using the FD2 data set, but agreement is good if the plutonium contributions in the calculations are omitted. The small positive Doppler coefficient calculated for Pu239 was not observed, and two measurements indicated instead a small negative effect. The Doppler effect in the mixed oxide systems was found to vary approximately as 1/T. The results from the empty loop and non-fissile assemblies indicate either a small negative Doppler effect in steel or alternatively the presence of an unexplained expansion effect. (author)

  13. Analysis of Radar Doppler Signature from Human Data

    Directory of Open Access Journals (Sweden)

    M. ANDRIĆ

    2014-04-01

    Full Text Available This paper presents the results of time (autocorrelation and time-frequency (spectrogram analyses of radar signals returned from the moving human targets. When a radar signal falls on the human target which is moving toward or away from the radar, the signals reflected from different parts of his body produce a Doppler shift that is proportional to the velocity of those parts. Moving parts of the body causes the characteristic Doppler signature. The main contribution comes from the torso which causes the central Doppler frequency of target. The motion of arms and legs induces modulation on the returned radar signal and generates sidebands around the central Doppler frequency, referred to as micro-Doppler signatures. Through analyses on experimental data it was demonstrated that the human motion signature extraction is better using spectrogram. While the central Doppler frequency can be determined using the autocorrelation and the spectrogram, the extraction of the fundamental cadence frequency using the autocorrelation is unreliable when the target is in the clutter presence. It was shown that the fundamental cadence frequency increases with increasing dynamic movement of people and simultaneously the possibility of its extraction is proportional to the degree of synchronization movements of persons in the group.

  14. Evaluating Peripheral Vascular Injuries: Is Color Doppler Enough for Diagnosis?

    Directory of Open Access Journals (Sweden)

    Mohd Lateef Wani

    2014-03-01

    Full Text Available Background:: Vascular injury poses a serious threat to limb and life. Thus, diagnosis should be made immediately with minimally invasive methods. Doppler is a good aid in diagnosis of vascular injury. Methods:: The present prospective study was conducted on 150 patients who presented with soft signs (the signs which are suggestive but not confirmatory of vascular injury. They were subjected to color Doppler examination before exploration. The patients with the features of vascular injury on color Doppler were subjected to exploration. On the other hand, those who had normal Doppler were subjected to CT- angiography. Then, the findings of the exploration were matched with those of color Doppler. The data were analyzed using the SPSS statistical software. Results:: Out of the 150 Doppler examinations, 110 (73.33% were reported as positive, while 40 were reported as negative for vascular injury. These were subjected to CT-angiography and seven of them had the features of vascular injury on CT-angiography. All the patients with positive Doppler or CT angiography findings were subjected to exploration. Doppler had a sensitivity of 94% and specificity of 82.5% in diagnosis of vascular injury using Binary classification test. Conclusions:: Color Doppler is an easily available, reliable, and handy method of diagnosing a vascular injury. It has a very high sensitivity and specificity in diagnosis of vascular injuries.

  15. Application of GRID to Foreign Atom Localization in Single Crystals.

    Science.gov (United States)

    Karmann, A; Wesch, W; Weber, B; Börner, H G; Jentschel, M

    2000-01-01

    The application of GRID (Gamma Ray Induced Doppler broadening) spectroscopy to the localization of foreign atoms in single crystals is demonstrated on erbium in YAP. By the investigation of the Doppler broadened secondary γ line for two crystalline directions, the Er was determined to be localized on the Y site. Conditions for the nuclear parameters of the impurity atoms used for the application of GRID spectroscopy are discussed.

  16. Sub-Doppler laser cooling of potassium atoms

    Energy Technology Data Exchange (ETDEWEB)

    Landini, M. [LENS and Dipartimento di Fisica e Astronomia, Universita di Firenze, I-50019 Sesto Fiorentino (Italy); INFN, Sezione di Firenze, I-50019 Sesto Fiorentino (Italy); Dipartimento di fisica, Universita di Trento, I-38123 Povo (Trento) (Italy); Roy, S.; Carcagni, L.; Trypogeorgos, D. [LENS and Dipartimento di Fisica e Astronomia, Universita di Firenze, I-50019 Sesto Fiorentino (Italy); Fattori, M.; Inguscio, M.; Modugno, G. [LENS and Dipartimento di Fisica e Astronomia, Universita di Firenze, I-50019 Sesto Fiorentino (Italy); INFN, Sezione di Firenze, I-50019 Sesto Fiorentino (Italy)

    2011-10-15

    We investigate the sub-Doppler laser cooling of bosonic potassium isotopes, whose small hyperfine splitting has so far prevented cooling below the Doppler temperature. We find instead that the combination of a dark optical molasses scheme that naturally arises in this kind of system and an adiabatic ramping of the laser parameters allows us to reach sub-Doppler temperatures for small laser detunings. We demonstrate temperatures as low as 25{+-}3 {mu}K and 47{+-}5 {mu}K in high-density samples of the two isotopes {sup 39}K and {sup 41}K, respectively. Our findings should find application to other atomic systems.

  17. Sub-Doppler laser cooling of potassium atoms

    International Nuclear Information System (INIS)

    Landini, M.; Roy, S.; Carcagni, L.; Trypogeorgos, D.; Fattori, M.; Inguscio, M.; Modugno, G.

    2011-01-01

    We investigate the sub-Doppler laser cooling of bosonic potassium isotopes, whose small hyperfine splitting has so far prevented cooling below the Doppler temperature. We find instead that the combination of a dark optical molasses scheme that naturally arises in this kind of system and an adiabatic ramping of the laser parameters allows us to reach sub-Doppler temperatures for small laser detunings. We demonstrate temperatures as low as 25±3 μK and 47±5 μK in high-density samples of the two isotopes 39 K and 41 K, respectively. Our findings should find application to other atomic systems.

  18. Methodology for obtaining wind gusts using Doppler lidar

    DEFF Research Database (Denmark)

    Suomi, Irene; Gryning, Sven-Erik; O'Connor, Ewan J.

    2017-01-01

    reduced the bias in the Doppler lidar gust factors from 0.07 to 0.03 and can be improved further to reduce the bias by using a realistic estimate of turbulence. Wind gust measurements are often prone to outliers in the time series, because they represent the maximum of a (moving-averaged) horizontal wind...... detection also outperformed the traditional Doppler lidar quality assurance method based on carrier-to-noise ratio, by removing additional unrealistic outliers present in the time series.......A new methodology is proposed for scaling Doppler lidar observations of wind gusts to make them comparable with those observed at a meteorological mast. Doppler lidars can then be used to measure wind gusts in regions and heights where traditional meteorological mast measurements are not available...

  19. CH3Cl self-broadening coefficients and their temperature dependence

    International Nuclear Information System (INIS)

    Dudaryonok, A.S.; Lavrentieva, N.N.; Buldyreva, J.V.

    2013-01-01

    CH 3 35 Cl self-broadening coefficients at various temperatures of atmospheric interest are computed by a semi-empirical method particularly suitable for molecular systems with strong dipole–dipole interactions. In order to probe the dependence on the rotational number K, the model parameters are adjusted on extensive room-temperature measurements for K≤7 and allow reproducing fine features of J-dependences observed for K≤3; for higher K up to 20, the fitting is performed on specially calculated semi-classical values. The temperature exponents for the standard power law are extracted and validated by calculation of low-temperature self-broadening coefficients comparing very favorably with available experimental data. An extensive line-list of self-broadening coefficients at the reference temperature 296 K and associated temperature exponents for 0≤J≤70, 0≤K≤20 is provided as Supplementary material for their use in atmospheric applications and spectroscopic databases. -- Highlights: • We calculated methyl chloride self-broadening coefficients using two methods. • Rotational quantum numbers were J from 0 till 70 and K from 0 till 20. • The temperature exponents were calculated for every mentioned line

  20. Corruption of radio metric Doppler due to solar plasma dynamics: S/X dual-frequency Doppler calibration for these effects

    Science.gov (United States)

    Winn, F. B.; Reinbold, S. R.; Yip, K. W.; Koch, R. E.; Lubeley, A.

    1975-01-01

    Doppler data from Mariner 6, 7, 9, and 10 and Pioneer 10 and 11 were discussed and the rms noise level for various sun-earth-probe angles were shown. The noise levels of both S- and X-band Doppler data for sun-earth-probe angles smaller than 20 deg were observed to be orders of magnitude greater than nominal. Such solar plasma-related Doppler degradation reduced the Mariner 10-Mercury 11 encounter navigation accuracy by nearly a factor of 10. Furthermore, this degradation was shown to be indirectly related to plasma dynamics and not a direct measure of the dynamics.

  1. Doppler Velocity Signatures of Idealized Elliptical Vortices

    Directory of Open Access Journals (Sweden)

    Wen-Chau Lee

    2006-01-01

    Full Text Available Doppler radar observations have revealed a class of atmospheric vortices (tropical cyclones, tornadoes, dust devils that possess elliptical radar reflectivity signatures. One famous example is Typhoon Herb (1996 that maintained its elliptical reflectivity structure over a 40-hour period. Theoretical work and dual-Doppler analyses of observed tropical cyclones have suggested two physical mechanisms that can explain the formation of two types of elliptical vortices observed in nature, namely, the combination of a circular vortex with either a wavenumber two vortex Rossby wave or a deformation field. The characteristics of these two types of elliptical vortices and their corresponding Doppler velocity signatures have not been previously examined.

  2. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The EDOP provides vertically profiled reflectivity and Doppler velocity at aircraft nadir along the flight track. The ER-2 Doppler radar (EDOP) is an X-band (9.6...

  3. Gold nanorods as a contrast agent for Doppler optical coherence tomography.

    Directory of Open Access Journals (Sweden)

    Bo Wang

    Full Text Available To investigate gold nanorods (GNRs as a contrast agent to enhance Doppler optical coherence tomography (OCT imaging of the intrascleral aqueous humor outflow.A serial dilution of GNRs was scanned with a spectral-domain OCT device (Bioptigen, Durham, NC to visualize Doppler signal. Doppler measurements using GNRs were validated using a controlled flow system. To demonstrate an application of GNR enhanced Doppler, porcine eyes were perfused at constant pressure with mock aqueous alone or 1.0×10(12 GNR/mL mixed with mock aqueous. Twelve Doppler and volumetric SD-OCT scans were obtained from the limbus in a radial fashion incremented by 30°, forming a circular scan pattern. Volumetric flow was computed by integrating flow inside non-connected vessels throughout all 12 scans around the limbus.At the GNR concentration of 0.7×10(12 GNRs/mL, Doppler signal was present through the entire depth of the testing tube without substantial attenuation. A well-defined laminar flow profile was observed for Doppler images of GNRs flowing through the glass capillary tube. The Doppler OCT measured flow profile was not statistically different from the expected flow profile based upon an autoregressive moving average model, with an error of -0.025 to 0.037 mm/s (p = 0.6435. Cross-sectional slices demonstrated the ability to view anterior chamber outflow ex-vivo using GNR-enhanced Doppler OCT. Doppler volumetric flow measurements were comparable to flow recorded by the perfusion system.GNRs created a measureable Doppler signal within otherwise silent flow fields in OCT Doppler scans. Practical application of this technique was confirmed in a constant pressure ex-vivo aqueous humor outflow model in porcine eyes.

  4. GRIP DOPPLER AEROSOL WIND LIDAR (DAWN) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Doppler Aerosol WiNd Lidar (DAWN) Dataset was collected by the Doppler Aerosol WiNd (DAWN), a pulsed lidar, which operated aboard a NASA DC-8 aircraft...

  5. Determination of line broadening constants in high pressure discharge lamps

    International Nuclear Information System (INIS)

    Weiss, M; Schubert, H; Meier, S; Born, M; Reiter, D; Stroesser, M

    2005-01-01

    A numerical model of the radiative transfer in high pressure metal halide discharge lamps is used to determine line broadening parameters for atomic scandium lines. The determined broadening constants are in qualitative agreement with theoretical estimates in many cases, but significant deviations exist. The data obtained from this paper can, therefore, be used to further improve modelling of radiative contributions to the energy balance in such types of discharge lamps

  6. Oxygen, nitrogen and air broadening of HCN spectral lines at terahertz frequencies

    International Nuclear Information System (INIS)

    Yang Chun; Buldyreva, Jeanna; Gordon, Iouli E.; Rohart, Francois; Cuisset, Arnaud; Mouret, Gael; Bocquet, Robin; Hindle, Francis

    2008-01-01

    The room-temperature nitrogen- and oxygen-broadening coefficients of hydrogen cyanide spectral lines have been measured in the 0.5-3 THz (17-100 cm -1 ) frequency range (purely rotational transitions with 5≤J≤36) by a continuous-wave terahertz spectrometer based on a photomixing source. An improved version of the Robert and Bonamy semiclassical formalism has been used to calculate the oxygen-broadening coefficients and resulted in a good agreement with these measurements. The nitrogen and oxygen data are combined to provide the air-broadening coefficients as used by the HITRAN database. A significant difference is observed between the measured and tabulated values for transitions with high values of the rotational quantum number. A new polynomial representation is suggested for inclusion in HITRAN. A similar polynomial expression has been derived for the nitrogen broadening to aid the studies of Titan's atmosphere

  7. Diabetic Nephropathy : Evaluation with Doppler Ultrasonography

    International Nuclear Information System (INIS)

    Sim, Jung Suk; Kim, Seung Hyup; Kang, Heung Sik; Park, Jae Hyung; Han, Man Chung

    1996-01-01

    To compare Doppler ultrasonography with laboratory tests in evaluation of diabetic nephropathy. Fifty-five patients (mean age = 60, M : F = 26 : 29) with diabetes mellitus underwent renal Doppler ultrasonography. Resistive indices were compared with degree of proteinuria, serum creatinine level, and creatinine clearance rate. Eighteen patients who showed no proteinuria or microscopic proteinuria had a mean resistive index (RI) of 0.72 (SD, 0.05), 16 patients with macroscopic proteinuria without nephrotic syndrome had a mean RI of 0.82 (SD, 0.13), and 21 patients with nephrotic syndrome had a mean RI of 0.90 (SD, 0.12). Renal RI correlated highly with serum creatinine level (r = 0.62) and creatinine clearance rate (r = -0.43). Renal Doppler ultrasonography provides a useful indication of renal function in diabetic nephropathy but cannot offer an advantage over conventional laboratory test

  8. Pressure broadening and frequency shift of the 5S1/2 → 5D5/2 and 5S1/2 → 7S1/2 two photon transitions in 85Rb by the noble gases and N2

    International Nuclear Information System (INIS)

    Zameroski, Nathan D; Hager, Gordon D; Erickson, Christopher J; Burke, John H

    2014-01-01

    Doppler free two photon absorption spectroscopy was employed to measure the pressure broadening and frequency shift rates of the 5S 1/2 (F = 3) → 5D 5/2 (F = 5, 4, 3, 2, 1) (778.105 nm) and the 5S 1/2 (F = 2) → 7S 1/2 (F = 2) (760.126 nm) two photon transitions in 85 Rb by the noble gases and N 2 . To our knowledge, these rates are reported on for the first time. The self-broadening and shift rate of the 5S 1/2 (F = 3) → 5D 5/2 (F = 5, 4, 3, 2, 1) transition and self -broadening rate of the 5S 1/2 (F = 2) → 7S 1/2 (F = 2) transition were also measured. The temperature dependence of the self-frequency shift (Rb-Rb collisions) of these transitions is presented. Helium diffusion rates through Quartz and Pyrex cells are also calculated and the implication of helium diffusion through glass vapor cells is discussed in regards to atomic frequency standards based on these transitions. Experimental pressure broadening and shift rates are compared to theoretically calculated rates assuming a 6, 8 or 6, 8, 10 difference potential and pseudo potential model. Reasonable agreement is achieved between experimental and theoretical values. (paper)

  9. Use of Doppler ultrasound for non-invasive urodynamic diagnosis

    Directory of Open Access Journals (Sweden)

    Hideo Ozawa

    2009-01-01

    Full Text Available Objectives: A totally non-invasive transperineal urodynamic technique using Doppler ultrasonography has been developed. Methods: Since normal urine does not have blood cells, urine was thought not to produce the Doppler effects. However, basic studies confirmed that the decrease of pressure at high velocity (Bernouilli effect caused dissolved gas to form microbubbles, which are detected by Doppler ultrasonography. Subjects sat and the probe was advanced via remote control to achieve gentle contact with the perineal skin. The digital uroflow data signals and the color Doppler ultrasound video images were processed on a personal computer. The flow-velocity curves from two sites; the distal prostatic urethra just above the external sphincter (V1 and the sphincteric urethra (V2 were plotted against time. The parameters of both the pressure-flow studies and the Doppler ultrasound urodynamic studies were compared in men who had various degrees of obstruction. Results: Functional cross-sectional area at prostatic urethra (A1, calculated by Q max /V1, was lower in the group of bladder outlet obstruction (BOO vs. control group. Velocity ratio (VR, which was calculated by V1/V2, was the parameter having the best correlation with BOO index, though A1 had a similar correlation. This method is viable to diagnose the degree of BOO. Conclusions: The development of non-invasive Doppler ultrasound videourodynamics (Doppler UDS will dramatically expand the information on voiding function.

  10. Line-Broadening in Low-Temperature Solid-State NMR Spectra of Fibrils

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Thomas; Dotta, Claudio; Balacescu, Livia; Gath, Julia; Hunkeler, Andreas [ETH Zurich, Physical Chemistry (Switzerland); Böckmann, Anja, E-mail: a.bockmann@ibcp.fr [Université de Lyon 1, Institut de Biologie et Chimie des Protéines, UMR 5086 CNRS (France); Meier, Beat H., E-mail: beme@ethz.ch [ETH Zurich, Physical Chemistry (Switzerland)

    2017-01-15

    The temperature-dependent resonance-line broadening of HET-s(218–289) in its amyloid form is investigated in the range between 110 K and 280 K. Significant differences are observed between residues in the structured hydrophobic triangular core, which are broadened the least and can be detected down to 100 K, and in the solvent-exposed parts, which are broadened the most and often disappear from the observed spectrum around 200 K. Below the freezing of the bulk water, around 273 K, the protein fibrils are still surrounded by a layer of mobile water whose thickness decreases with temperature, leading to drying out of the fibrils.

  11. GOLD: Building capacity for broadening participation in the Geosciences

    Science.gov (United States)

    Adams, Amanda; Patino, Lina; Jones, Michael B.; Rom, Elizabeth

    2017-04-01

    The geosciences continue to lag other science, technology, engineering, and mathematics (STEM) disciplines in the engagement, recruitment and retention of traditionally underrepresented and underserved minorities, requiring more focused and strategic efforts to address this problem. Prior investments made by the National Science Foundation (NSF) related to broadening participation in STEM have identified many effective strategies and model programs for engaging, recruiting, and retaining underrepresented students in the geosciences. These investments also have documented clearly the importance of committed, knowledgeable, and persistent leadership for making local progress in broadening participation in STEM and the geosciences. Achieving diversity at larger and systemic scales requires a network of diversity "champions" who can catalyze widespread adoption of these evidence-based best practices and resources. Although many members of the geoscience community are committed to the ideals of broadening participation, the skills and competencies that empower people who wish to have an impact, and make them effective as leaders in that capacity for sustained periods of time, must be cultivated through professional development. The NSF GEO Opportunities for Leadership in Diversity (GOLD) program was implemented in 2016, as a funding opportunity utilizing the Ideas Lab mechanism. Ideas Labs are intensive workshops focused on finding innovative solutions to grand challenge problems. The ultimate aim of this Ideas Lab, organized by the NSF Directorate for Geosciences (GEO), was to facilitate the design, pilot implementation, and evaluation of innovative professional development curricula that can unleash the potential of geoscientists with interests in broadening participation to become impactful leaders within the community. The expectation is that mixing geoscientists with experts in broadening participation research, behavioral change, social psychology, institutional

  12. LINE BROADENING AND THE SOLAR OPACITY PROBLEM

    Energy Technology Data Exchange (ETDEWEB)

    Krief, M.; Feigel, A.; Gazit, D., E-mail: menahem.krief@mail.huji.ac.il [The Racah Institute of Physics, The Hebrew University, 91904 Jerusalem (Israel)

    2016-06-20

    The calculation of line widths constitutes theoretical and computational challenges in the calculation of opacities of hot, dense plasmas. Opacity models use line broadening approximations that are untested at stellar interior conditions. Moreover, calculations of atomic spectra of the Sun indicate a large discrepancy in the K-shell line widths between several atomic codes and the Opacity-Project (OP). In this work, the atomic code STAR is used to study the sensitivity of solar opacities to line broadening. Variations in the solar opacity profile due to an increase of the Stark widths resulting from discrepancies with OP, are compared, in light of the solar opacity problem, with the required opacity variations of the present day Sun, as imposed by helioseismic and neutrino observations. The resulting variation profile is much larger than the discrepancy between different atomic codes, agrees qualitatively with the missing opacity profile, recovers about half of the missing opacity nearby the convection boundary, and has a little effect in the internal regions. Since it is hard to estimate quantitatively the uncertainty in the Stark widths, we show that an increase of all line widths by a factor of about ∼100 recovers quantitatively the missing opacity. These results emphasize the possibility that photoexcitation processes are not modeled properly, and more specifically, highlight the need for a better theoretical characterization of the line broadening phenomena at stellar interior conditions, and of the uncertainty due to the way it is implemented by atomic codes.

  13. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    Science.gov (United States)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  14. Temporal Doppler Effect and Future Orientation: Adaptive Function and Moderating Conditions.

    Science.gov (United States)

    Gan, Yiqun; Miao, Miao; Zheng, Lei; Liu, Haihua

    2017-06-01

    The objectives of this study were to examine whether the temporal Doppler effect exists in different time intervals and whether certain individual and environmental factors act as moderators of the effect. Using hierarchical linear modeling, we examined the existence of the temporal Doppler effect and the moderating effect of future orientation among 139 university students (Study 1), and then the moderating conditions of the temporal Doppler effect using two independent samples of 143 and 147 university students (Studies 2 and 3). Results indicated that the temporal Doppler effect existed in all of our studies, and that future orientation moderated the temporal Doppler effect. Further, time interval perception mediated the relationship between future orientation and the motivation to cope at long time intervals. Finally, positive affect was found to enhance the temporal Doppler effect, whereas control deprivation did not influence the effect. The temporal Doppler effect is moderated by the personality trait of future orientation and by the situational variable of experimentally manipulated positive affect. We have identified personality and environmental processes that could enhance the temporal Doppler effect, which could be valuable in cases where attention to a future task is necessary. © 2016 Wiley Periodicals, Inc.

  15. Double-resonance optical-pumping effect and ladder-type electromagnetically induced transparency signal without Doppler background in cesium atomic vapour cell

    International Nuclear Information System (INIS)

    Yang Bao-Dong; Gao Jing; Liang Qiang-Bing; Wang Jie; Zhang Tian-Cai; Wang Jun-Min

    2011-01-01

    In a Doppler-broadened ladder-type cesium atomic system (6S 1/2 -6P 3/2 -8S 1/2 ), this paper characterizes electromagnetically induced transparency (EIT) in two different experimental arrangements, and investigates the influence of the double-resonance optical-pumping (DROP) effect on EIT in both arrangements. When the probe laser is weak, DROP is explicitly suppressed. When the probe laser is moderate, population of the intermediate level (6P 3/2 F' = 5) is remarkable, therefore DROP is mixed with EIT. An interesting bimodal spectrum with the broad component due to DROP and the narrow part due to EIT has been clearly observed in cesium 6S 1/2 F = 4−6P 3/2 F' = 5−8S 1/2 F″ = 4 transitions. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  16. Oxygen, nitrogen and air broadening of HCN spectral lines at terahertz frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Yang Chun [Laboratoire de Physico-Chimie de l' Atmosphere, UMR CNRS 8101, Universite du Littoral Cote d' Opale, 189A Av. Maurice Schumann, 59140 Dunkerque (France); Buldyreva, Jeanna [Institut UTINAM, UMR CNRS 6213, Universite de Franche-Comte, 16, Route de Gray, 25030 Besancon Cedex (France); Gordon, Iouli E. [Harvard-Smithsonian Center for Astrophysics, Atomic and Molecular Physics Division, 60 Garden Street, Cambridge, MA 02138-1516 (United States); Rohart, Francois [Laboratoire de Physique des Lasers, Atomes et Molecules, UMR CNRS 8523, Batiment P5-135, Universite de Lille 1, 59655 Villeneuve d' Ascq Cedex (France); Cuisset, Arnaud; Mouret, Gael; Bocquet, Robin [Laboratoire de Physico-Chimie de l' Atmosphere, UMR CNRS 8101, Universite du Littoral Cote d' Opale, 189A Av. Maurice Schumann, 59140 Dunkerque (France); Hindle, Francis [Laboratoire de Physico-Chimie de l' Atmosphere, UMR CNRS 8101, Universite du Littoral Cote d' Opale, 189A Av. Maurice Schumann, 59140 Dunkerque (France)], E-mail: francis.hindle@univ-littoral.fr

    2008-11-15

    The room-temperature nitrogen- and oxygen-broadening coefficients of hydrogen cyanide spectral lines have been measured in the 0.5-3 THz (17-100 cm{sup -1}) frequency range (purely rotational transitions with 5{<=}J{<=}36) by a continuous-wave terahertz spectrometer based on a photomixing source. An improved version of the Robert and Bonamy semiclassical formalism has been used to calculate the oxygen-broadening coefficients and resulted in a good agreement with these measurements. The nitrogen and oxygen data are combined to provide the air-broadening coefficients as used by the HITRAN database. A significant difference is observed between the measured and tabulated values for transitions with high values of the rotational quantum number. A new polynomial representation is suggested for inclusion in HITRAN. A similar polynomial expression has been derived for the nitrogen broadening to aid the studies of Titan's atmosphere.

  17. New clutter-rejection algorithm for Doppler ultrasound

    Science.gov (United States)

    Cloutier, Guy; Chen, Danmin; Durand, Louis-Gilles

    2002-04-01

    Several strategies, known as clutter or wall Doppler filtering, were proposed to remove the strong echoes produced by stationary or slow moving tissue structures from the Doppler blood flow signal. In this study, the matching pursuit (MP) method is proposed to remove clutter components. The MP method decomposes the Doppler signal into wavelet atoms that are selected in a decreasing energy order. Thus, the high-energy clutter components are extracted first. In the present study, the pulsatile Doppler signal s(n) was simulated by a sum of random-phase sinusoids. Two types of high-amplitude clutter signals were then superimposed on s(n): a time-varying low frequency component (type 1), covering systole and early diastole, and short transient clutter signals (type 2), distributed within the whole cardiac cycle. The Doppler signals were modeled with the MP method and the most dominant atoms were subtracted until the signal-to-clutter (S/C) ratio reached a maximum. For the type 1 clutter signal, the improvement in the S/C ratio was 19.0 +/- 0.6 dB, and 72.0 +/- 4.5 atoms were required to reach this performance. For the transient type 2 clutter signal, exactly 10 atoms were required and the maximum improvement in S/C ratio was 5.5 +/- 0.5 dB. These results suggest the possibility of using this signal processing approach to implement clutter rejection filters on ultrasound commercial instruments.

  18. Molecules cooled below the Doppler limit

    Science.gov (United States)

    Truppe, S.; Williams, H. J.; Hambach, M.; Caldwell, L.; Fitch, N. J.; Hinds, E. A.; Sauer, B. E.; Tarbutt, M. R.

    2017-12-01

    Magneto-optical trapping and sub-Doppler cooling have been essential to most experiments with quantum degenerate gases, optical lattices, atomic fountains and many other applications. A broad set of new applications await ultracold molecules, and the extension of laser cooling to molecules has begun. A magneto-optical trap (MOT) has been demonstrated for a single molecular species, SrF, but the sub-Doppler temperatures required for many applications have not yet been reached. Here we demonstrate a MOT of a second species, CaF, and we show how to cool these molecules to 50 μK, well below the Doppler limit, using a three-dimensional optical molasses. These ultracold molecules could be loaded into optical tweezers to trap arbitrary arrays for quantum simulation, launched into a molecular fountain for testing fundamental physics, and used to study collisions and chemistry between atoms and molecules at ultracold temperatures.

  19. Commitment to Broadening Participation at NOAO

    Science.gov (United States)

    Garmany, Catharine D.; Norman, D.

    2011-01-01

    AURA and NOAO take seriously the importance of Broadening Participation in Astronomy. At the request of the AURA President, each of the AURA centers (NOAO, NSO, STSCI, Gemini) appointed a Diversity Advocates (DA). At NOAO this job is shared by Dara Norman and Katy Garmany, who were appointed by Dave Silva in Jan 2009. The DA's are members of the AURA Committee on Workforce and Diversity (WDC), a designated subcommittee of the AURA Board of Directors. The role of this committee includes reviewing activities and plans on an AURA wide basis aimed at broadening the participation within AURA, and reviewing AURA wide policies on the workforce. At NOAO, the role of the DAs spans a number of departments and activities. They serve on observatory search committees, and offer suggestions on how NOAO job searches can reach the most diverse audience. The DA's job is to insure that NOAO actively pursues every opportunity to increase diversity: to this end they are involved in outreach and educational activities that focus on workplace development and encourage inclusion of woman, minorities and persons with disabilities.

  20. Tunable Optical Delay in Doppler-Broadened Cesium Vapor

    Science.gov (United States)

    2010-12-01

    REFERENCE: 36 % [1] J. M. Amini and H. Gould 37 % High Precision Measurement of the Static Dipole Polarizability of Cs 38 % Phys. Rev. Lett., American... polarizability of cesium. Phys. Rev. Lett. 91 (15), 153001. Andalkar, A. and R. B. Warrington (2002, Feb). High-resolution measurement of the pressure...Physics Publishing. Morgus, L., T. Morgus, T. Drake, and J. Huennekens (2008). Hyperfine state- changing collisions of Cs (6p1/2) atoms with argon

  1. Structural changes between 100 and 300 K of the high-Tc superconductor Y-Ba-Cu-O studied by positron annihilation

    International Nuclear Information System (INIS)

    Wang, S.J.; Li, X.H.; Chen, Y.L.; Li, S.Q.; Fong, G.H.; Wang, Z.

    1989-01-01

    The structural changes of the high-T c superconductor Y-Ba-Cu-O between 100 and 300 K are studied by positron lifetime and Doppler broadening measurements as a function of temperature. There are anomalous changes in the positron lifetimes and Doppler broadening S-parameters near 130 and 260 K, which is consistent with some reported experimental results. These anomalies may be caused by the lattice instabilities, such as the ordering readjustment of oxygen vacancies. (author)

  2. An In-situ method for the study of strain broadening usingsynchrotronx-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chiu C.; Lynch, Peter A.; Cheary, Robert W.; Clark, Simon M.

    2006-12-15

    A tensonometer for stretching metal foils has beenconstructed for the study of strain broadening in x-ray diffraction lineprofiles. This device, which is designed for use on the powderdiffractometer in Station 2.3 at Daresbury Laboratory, allows in-situmeasurements to be performed on samples under stress. It can be used fordata collection in either transmission or reflection modes using eithersymmetric or asymmetric diffraction geometries. As a test case,measurements were carried out on a 18mum thick copper foil experiencingstrain levels of up to 5 percent using both symmetric reflection andsymmetric transmission diffraction. All the diffraction profilesdisplayed peak broadening and asymmetry which increased with strain. Themeasured profiles were analysed by the fundamental parameters approachusing the TOPAS peak fitting software. All the observed broadenedprofiles were modelled by convoluting a refineable diffraction profile,representing the dislocation and crystallite size broadening, with afixed instrumental profile pre-determined usinghigh quality LaB6reference powder. The de-convolution process yielded "pure" sampleintegral breadths and asymmetry results which displayed a strongdependence on applied strain and increased almost linearly with appliedstrain. Assuming crystallite size broadening in combination withdislocation broadening arising from fcc a/2<110>111 dislocations,we have extracted the variation of mechanic al property with strain. Theobservation of both peak asymmetry and broadening has been interpreted asa manifestation of a cellular structure with cell walls and cellinteriors possessing high and low dislocation densities.

  3. The Tsallis Statistics applied to the calculation of absorption cross section of {sup 238}U, {sup 232}Th and {sup 240}Pu isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Guedes, Guilherme, E-mail: gguedes.cefet@gmail.com [Centro Federal de Educacao Tecnologica Celso Suckow da Fonseca (CEFET-RJ), Nova Friburgo, RJ (Brazil); Gonçalves, Alessandro C., E-mail: alessandrocgnuclear@gmail.com [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil); Palma, Daniel A.P., E-mail: dapalma@cnen.gov.br [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The thermal agitation movement in the reactor core is adequately represented by the microscopic cross section of the neutron-nucleus interaction through the Doppler broadening function. In the last decades several researches had been done on fundamentals and applications of generalized statistical theories based on quasi-Maxwellian distribution of probabilities. In this paper the effect of taking into account the non extensive Tsallis statistics in the evaluation of the absorption cross section in 3-dimension is discussed. In this context, it is obtained an integral form for a generalized Doppler broadening function in the scope of the single-level formalism given by the Bethe-Placzek approximations. This new function reproduces the well-established conventional Doppler broadening function on the limit when q removes the deformation. Numerical tests were carried out and by varying the q parameter it was possible to study the range of values where the effect is appreciable. (author)

  4. Doppler ultrasound imaging techniques for assessment of synovial inflammation

    Directory of Open Access Journals (Sweden)

    Filippucci E

    2013-09-01

    Full Text Available Emilio Filippucci,1 Fausto Salaffi,1 Marina Carotti,2 Walter Grassi1 1Rheumatology Department, Polytechnic University of the Marche, Ancona, Italy; 2Department of Radiology, Polytechnic University of the Marche, Ancona, Italy Abstract: Ultrasound is an evolving technique, and the rapid progress made in ultrasound technology over the past ten years has dramatically increased its range of applications in rheumatology. One of the most exciting advances is the use of Doppler ultrasound imaging in the assessment of blood flow abnormalities at the synovial tissue level in patients with chronic inflammatory arthritis. This review describes the Doppler techniques available and their main applications in patients with inflammatory arthritis, discusses the evidence supporting their use, and outlines the latest advances in hardware and software. Spectral, color, and power Doppler allow sensitive assessment of vascular abnormalities at the synovial tissue level. Use of contrast agents enhances visualization of the small synovial vessels using color or power Doppler ultrasound and allows for accurate characterization of the rheumatoid pannus. Doppler techniques represent a unique method for assessment of synovial inflammation, showing blood flow characteristics in real time. They are safe, noninvasive, cost-effective, and have high sensitivity in revealing and monitoring synovitis. However, several questions still need to be answered. In the near future, the Doppler techniques described here, together with upcoming hardware and software facilities, will be investigated further and a consensus will be reached on their feasibility and appropriate use in daily rheumatologic practice. Keywords: power and color Doppler techniques, ultrasound, contrast media, synovitis, rheumatoid arthritis

  5. Doppler Shift Compensation Schemes in VANETs

    Directory of Open Access Journals (Sweden)

    F. Nyongesa

    2015-01-01

    Full Text Available Over the last decade vehicle-to-vehicle (V2V communication has received a lot of attention as it is a crucial issue in intravehicle communication as well as in Intelligent Transportation System (ITS. In ITS the focus is placed on integration of communication between mobile and fixed infrastructure to execute road safety as well as nonsafety information dissemination. The safety application such as emergence alerts lays emphasis on low-latency packet delivery rate (PDR, whereas multimedia and infotainment call for high data rates at low bit error rate (BER. The nonsafety information includes multimedia streaming for traffic information and infotainment applications such as playing audio content, utilizing navigation for driving, and accessing Internet. A lot of vehicular ad hoc network (VANET research has focused on specific areas including channel multiplexing, antenna diversity, and Doppler shift compensation schemes in an attempt to optimize BER performance. Despite this effort few surveys have been conducted to highlight the state-of-the-art collection on Doppler shift compensation schemes. Driven by this cause we survey some of the recent research activities in Doppler shift compensation schemes and highlight challenges and solutions as a stock-taking exercise. Moreover, we present open issues to be further investigated in order to address the challenges of Doppler shift in VANETs.

  6. Contrast-enhanced power Doppler US in the characterization of renal masses; Power Doppler con mezzo di contrasto nella caratterizzazione delle masse renali

    Energy Technology Data Exchange (ETDEWEB)

    Ascenti, G.; Zimbaro, G.; Mazziotti, S.; Visalli, C.; Racchiusa, S.; Vinci, S.; Scribano, E. [Messina Univ., Messina (Italy). Ist. di Scienze Radiologiche

    2000-09-01

    Purpose of this work is to report the results of a prospective study investigating the potentials of contrast-enhanced power Doppler in the diagnosis of expansive renal lesions. From 1997 to October 30, 1999, it was studied the case of 59 expansive renal lesions (28 malignant, 31 benign) in 48 patients (mean age 55 years, range 10-79) with power Doppler US before and after the administration of an echo-enhancing agent (Levovist, Schering AG, Berlin Germany). Were found 5 patterns of vascular architecture of the lesions, both before and after contrast agent administration, following the classification by Jinzaki e Coll. Power Doppler US showed vascular structures in 34 patients. The administration of Levovist revealed vessels in 12/25 lesions which had none at baseline studies and in 6 cases vascularity was particularly evident. Color signals were enhanced in all the 34 vascularized lesions, which allowed better definition of vascular patterns. The characterization of vascular patterns with baseline power Doppler US helped improve diagnostic accuracy compared to gray-scale US (58% versus 32%) for hyperechoic lesions, complex cysts and pseudomasses. Independent of contrast agent administration, the integration of gray-scale and power Doppler modes increased diagnostic accuracy even further (76% correct diagnoses). In our series, the US contrast agent did not increase the diagnostic accuracy of power Doppler in the differential diagnosis of hyperechoic renal lesions; conversely, Levovist can be advantageous for the characterization of suspected pseudomasses and complex cysts. [Italian] Scopo di questo articolo e' quello di riportare i risultati di uno studio prospettico finalizzato ad individuare le potenzialita' del power Doppler con mdc ecografico nella caratterizzazione delle lesioni espansive del rene. Dal 1997 al 30 ottobre 1999 sono state studiate 59 lesioni renali (28 maligne, 31 benigne) in 48 pazienti (eta' media 55 anni, intervallo 10

  7. Comparison between Doppler Ultrasound and Biopsy Findings in ...

    African Journals Online (AJOL)

    Methods: We retrospectively studied a random sample of 188 kidney transplanted patients who had Doppler-ultrasound examination followed within two weeks by transplant biopsy. We evaluated the specificity and sensitivity of Doppler ultrasound in diagnosing rejection at different RI thresholds, using the reported biopsy ...

  8. Acute intrascrotal pathology in childhood: color Doppler study

    International Nuclear Information System (INIS)

    Cinta Sanguesa, C.; Muro, D.; Cortina, H.; Moreno, A.

    1997-01-01

    To asses the utility of color Doppler ultrasound in the study of acute intrascrotal pathology in childhood. Seventy-five boys with evidence of an acute intrascrotal abnormality were studied by means of color Doppler ultrasound. A 7.5 MHz linear transducer was used. The most common findings was inflammatory disease (60%) which was indicated by the presence of hyperemia in color Doppler. Of the nine boys with testicular torsion (12%) two presented extravaginal torsion, with a complete absence of intratesticular vascularization. Intravaginal torsion was observed in seven patients, six of whom presented reduced vascularization in the abnormal testicle with respect to the healthy testicle. There was one false negative in which testicular vascularization was normal but 360 degree centigree torsion was found at surgery. In addition, there were seven cases of hydatid torsion (9.33%), four of idiopathic scrotal swelling (5.3%). two cases of intermittent torsion (2.6%) and one case of Shcolein-Henoch purpura (1.3%). The ultrasound findings were completely nornal in seven boys. Color Doppler is a rapid, noninvasive method for assessing testicular blood flow. The elevated sensitivity and specificity (85.7 and 100%, respectively, in our series) for testicular torsion make Doppler ultrasound a highly reliable method for the study of this disorder. (Author) 18 refs

  9. Deconvolving instrumental and intrinsic broadening in core-shell x-ray spectroscopies

    International Nuclear Information System (INIS)

    Fister, T. T.; Seidler, G. T.; Rehr, J. J.; Kas, J. J.; Nagle, K. P.; Elam, W. T.; Cross, J. O.

    2007-01-01

    Intrinsic and experimental mechanisms frequently lead to broadening of spectral features in core-shell spectroscopies. For example, intrinsic broadening occurs in x-ray absorption spectroscopy (XAS) measurements of heavy elements where the core-hole lifetime is very short. On the other hand, nonresonant x-ray Raman scattering (XRS) and other energy loss measurements are more limited by instrumental resolution. Here, we demonstrate that the Richardson-Lucy (RL) iterative algorithm provides a robust method for deconvolving instrumental and intrinsic resolutions from typical XAS and XRS data. For the K-edge XAS of Ag, we find nearly complete removal of ∼9.3 eV full width at half maximum broadening from the combined effects of the short core-hole lifetime and instrumental resolution. We are also able to remove nearly all instrumental broadening in an XRS measurement of diamond, with the resulting improved spectrum comparing favorably with prior soft x-ray XAS measurements. We present a practical methodology for implementing the RL algorithm in these problems, emphasizing the importance of testing for stability of the deconvolution process against noise amplification, perturbations in the initial spectra, and uncertainties in the core-hole lifetime

  10. Peak broadening in paper chromatography and related techniques : III. Peak broadening in thin-layer chromatography on cellulose powder

    NARCIS (Netherlands)

    Ligny, C.L. de; Remijnse, A.G.

    1968-01-01

    The mechanism of peak broadening in thin-layer chromatography on cellulose powder was investigated by comparing the peak widths obtained in chromatography with those caused only by diffusion in the cellulose powder, for a set of amino acids of widely differing RF values and six kinds of cellulose

  11. Arm locking with Doppler estimation errors

    Energy Technology Data Exchange (ETDEWEB)

    Yu Yinan; Wand, Vinzenz; Mitryk, Shawn; Mueller, Guido, E-mail: yinan@phys.ufl.ed [Department of Physics, University of Florida, Gainesville, FL 32611 (United States)

    2010-05-01

    At the University of Florida we developed the University of Florida LISA Interferometer Simulator (UFLIS) in order to study LISA interferometry with hardware in the loop at a system level. One of the proposed laser frequency stabilization techniques in LISA is arm locking. Arm locking uses an adequately filtered linear combination of the LISA arm signals as a frequency reference. We will report about experiments in which we demonstrated arm locking using UFLIS. During these experiments we also discovered a problem associated with the Doppler shift of the return beam. The initial arm locking publications assumed that this Doppler shift can perfectly be subtracted inside the phasemeter or adds an insignificant offset to the sensor signal. However, the remaining Doppler knowledge error will cause a constant change in the laser frequency if unaccounted for. Several ways to circumvent this problem have been identified. We performed detailed simulations and started preliminary experiments to verify the performance of the proposed new controller designs.

  12. On the Application of Stark Broadening Data Determined with a Semiclassical Perturbation Approach

    Directory of Open Access Journals (Sweden)

    Milan S. Dimitrijević

    2014-08-01

    Full Text Available The significance of Stark broadening data for problems in astrophysics, physics, as well as for technological plasmas is discussed and applications of Stark broadening parameters calculated using a semiclassical perturbation method are analyzed.

  13. Magnon Broadening Effect by Magnon-Phonon Interaction in Colossal Magnetoresistance Manganites

    OpenAIRE

    Furukawa, Nobuo

    1999-01-01

    In order to study the magnetic excitation behaviors in colossal magnetoresistance manganites, a magnon-phonon interacting system is investigated. Sudden broadening of magnon linewidth is obtained when a magnon branch crosses over an optical phonon branch. Onset of the broadening is approximately determined by the magnon density of states. Anomalous magnon damping at the brillouine zone boundary observed in low Curie temperature manganites is explained.

  14. Low-Frequency Gravitational Wave Searches Using Spacecraft Doppler Tracking

    Directory of Open Access Journals (Sweden)

    Armstrong J. W.

    2006-01-01

    Full Text Available This paper discusses spacecraft Doppler tracking, the current-generation detector technology used in the low-frequency (~millihertz gravitational wave band. In the Doppler method the earth and a distant spacecraft act as free test masses with a ground-based precision Doppler tracking system continuously monitoring the earth-spacecraft relative dimensionless velocity $2 Delta v/c = Delta u/ u_0$, where $Delta u$ is the Doppler shift and $ u_0$ is the radio link carrier frequency. A gravitational wave having strain amplitude $h$ incident on the earth-spacecraft system causes perturbations of order $h$ in the time series of $Delta u/ u_0$. Unlike other detectors, the ~1-10 AU earth-spacecraft separation makes the detector large compared with millihertz-band gravitational wavelengths, and thus times-of-flight of signals and radio waves through the apparatus are important. A burst signal, for example, is time-resolved into a characteristic signature: three discrete events in the Doppler time series. I discuss here the principles of operation of this detector (emphasizing transfer functions of gravitational wave signals and the principal noises to the Doppler time series, some data analysis techniques, experiments to date, and illustrations of sensitivity and current detector performance. I conclude with a discussion of how gravitational wave sensitivity can be improved in the low-frequency band.

  15. Laser Doppler measurements in two-phase flows

    International Nuclear Information System (INIS)

    Durst, F.; Zare, M.

    1976-01-01

    Basic theory for laser-Doppler velocity measurements of large reflecting or refracting surfaces is provided. It is shown that the Doppler-signals contain information of the velocity and size of the large bodies, and relationships for transforming velocity and radius of curvature of moving spheres are presented. Preliminary experiments verified the analytical findings and demonstrated the applicability of the method to some two-phase flows

  16. Hβ Stark broadening in cold plasmas with low electron densities calibrated with Thomson scattering

    International Nuclear Information System (INIS)

    Palomares, J.M.; Hübner, S.; Carbone, E.A.D.; Vries, N. de; Veldhuizen, E.M. de; Sola, A.; Gamero, A.; Mullen, J.J.A.M. van der

    2012-01-01

    In the present work Stark broadening measurements have been carried out on low electron density (n e 19 m −3 ) and (relatively) low gas temperature (T g e . - Highlights: ► Stark broadening measurements at low density and temperature conditions ► Calibration with Thomson scattering ► Indications of the non-Lorentzian shape of the Stark broadening ► Impossibility of simultaneous diagnostic of gas temperature and electron density

  17. Transversal Doppler-Fizeau effect

    International Nuclear Information System (INIS)

    Subacius, E.

    1981-01-01

    The relativistic calculation of the Doppler-Fizeau effect foresees a second grade redshift due to the proper time dilation of a moving object. The relevance of this relativistic effect on astrophysical observation is discussed, herein. (Auhor) [pt

  18. Operational Bright-Band Snow Level Detection Using Doppler Radar

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A method to detect the bright-band snow level from radar reflectivity and Doppler vertical velocity data collection with an atmospheric profiling Doppler radar. The...

  19. Distribution of Doppler Redshifts of Associated Absorbers of SDSS ...

    Indian Academy of Sciences (India)

    The authors searched all ... quasar, where the contribution of the Doppler motion is relatively small. ..... might contribute to the Doppler redshift distribution. 5. ... out accounting for the contamination of intervening absorption systems, which can.

  20. Settings and artefacts relevant for Doppler ultrasound in large vessel vasculitis

    DEFF Research Database (Denmark)

    Terslev, L; Diamantopoulos, A P; Døhn, U Møller

    2017-01-01

    Ultrasound is used increasingly for diagnosing large vessel vasculitis (LVV). The application of Doppler in LVV is very different from in arthritic conditions. This paper aims to explain the most important Doppler parameters, including spectral Doppler, and how the settings differ from those used...

  1. A new formulation for resonance self-shielding factors

    International Nuclear Information System (INIS)

    Palma, Daniel A.P.; Martinez, Aquilino S.; Silva, Fernando C. da

    2007-01-01

    The activation technique allows either absolute or relative very precise neutron intensity measurements. This technique requires the knowledge of the Doppler broadening function to determine resonance self-shielding factors. In the present work a new formulation is proposed for the self-shielding factors where the Doppler broadening function is calculated using the Frobenius's method and compared to the values obtained from the four-pole Pade method. This calculation method is shown to be effective from the point of view of accuracy. (author)

  2. Vacancy identification in Co+ doped rutile TiO2 crystal with positron annihilation spectroscopy

    Science.gov (United States)

    Qin, X. B.; Zhang, P.; Liang, L. H.; Zhao, B. Z.; Yu, R. S.; Wang, B. Y.; Wu, W. M.

    2011-01-01

    Co-doped rutile TiO2 films were synthesized by ion implantation. Variable energy positron annihilation Doppler broadening spectroscopy and coincidence Doppler broadening measurements were performed for identification of the vacancies. A newly formed type of vacancy can be concluded by the S-W plot and the CDB results indicated that the oxygen vacancy (VO) complex Ti-Co-VO and/or Ti-VO are formed with Co ions implantation and the vacancy concentration is increased with increase of dopant dose.

  3. Ion-irradiated polymer studied by a slow positron beam

    International Nuclear Information System (INIS)

    Kobayashi, Yoshinori; Kojima, Isao; Hishita, Shunichi; Suzuki, Takenori.

    1995-01-01

    Poly (aryl-ether-ether ketone) (PEEK) films were irradiated with 1MeV and 2MeV 0 + ions and the positron annihilation Doppler broadening was measured as a function of the positron energy. The annihilation lines recorded at relatively low positron energies were found to become broader with increasing the irradiation dose, suggesting that positronium (Ps) formation may be inhibited in the damaged regions. A correlation was observed between the Doppler broadening and spin densities determined by electron spin resonance (ESR). (author)

  4. [Diagnostic value of power Doppler ultrasonography for Sirenomelia Seguence in prenatal].

    Science.gov (United States)

    Yan, Xia-yu; Yang, Tai-zhu; Luo, Hong; Tian, Yu; Yang, Fan

    2011-11-01

    To study and discuss the diagnostic value and ultrasonographic characteristics of power doppler ultrasound in the prenatal diagnosis of Sirenomelia Seguence. The abdominal aorta in two fetuses with sirenomelia seguence fetuses and in ten with nomal was reviewed and compared with two-dimensional power doppler ultrasound and three-dimensional power doppler ultrasound in prenatal. The abdominal aorta were showed to divid into renal arteries in the kidney level while two common iliac arteries in the pelvis in nomal fetuses with two-dimensional power doppler ultrasound and three-dimensional power doppler ultrasound; compared with the nomal, the abdominal aorta and whose branches in sirenomelia seguence were demonstrated as follows: 1) a large and deformed vascular coming from the high abdominal aorta, which was found to act as a umbilical artery by careful examination; 2) no bifurcation of renal arteries identified; 3) no bifurcation of two common iliac arteries identified; 4) the abdominal aorta changing into a narrow vascular after one deformed vascular separating from. Sirenomelia seguence fetuses has a characteristic change in two-dimensional power doppler ultrasound and three-dimensional power doppler ultrasound, which is helpful to improve the prenatal diagnosis of sirenomelia seguence.

  5. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    International Nuclear Information System (INIS)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon

    2002-01-01

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  6. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon [Hallym University College of Medicine, Seoul (Korea, Republic of)

    2002-09-15

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  7. Doppler Temperature Coefficient Calculations Using Adjoint-Weighted Tallies and Continuous Energy Cross Sections in MCNP6

    Science.gov (United States)

    Gonzales, Matthew Alejandro

    version of MCNP6. Temperature feedback results from the cross sections themselves, changes in the probability density functions, as well as changes in the density of the materials. The focus of this work is specific to the Doppler temperature feedback which result from Doppler broadening of cross sections as well as changes in the probability density function within the scattering kernel. This method is compared against published results using Mosteller's numerical benchmark to show accurate evaluations of the Doppler temperature coefficient, fuel assembly calculations, and a benchmark solution based on the heavy gas model for free-gas elastic scattering. An infinite medium benchmark for neutron free gas elastic scattering for large scattering ratios and constant absorption cross section has been developed using the heavy gas model. An exact closed form solution for the neutron energy spectrum is obtained in terms of the confluent hypergeometric function and compared against spectra for the free gas scattering model in MCNP6. Results show a quick increase in convergence of the analytic energy spectrum to the MCNP6 code with increasing target size, showing absolute relative differences of less than 5% for neutrons scattering with carbon. The analytic solution has been generalized to accommodate piecewise constant in energy absorption cross section to produce temperature feedback. Results reinforce the constraints in which heavy gas theory may be applied resulting in a significant target size to accommodate increasing cross section structure. The energy dependent piecewise constant cross section heavy gas model was used to produce a benchmark calculation of the Doppler temperature coefficient to show accurate calculations when using the adjoint-weighted method. Results show the Doppler temperature coefficient using adjoint weighting and cross section derivatives accurately obtains the correct solution within statistics as well as reduce computer runtimes by a factor of 50.

  8. Study of peak broadening effect in floor time histories

    International Nuclear Information System (INIS)

    Soni, R.S.; Kushwaha, H.S.; Mahajan, S.C.; Kakodkar, A.

    1996-01-01

    Seismic design of secondary systems such components and piping is usually carried out by using the floor motions at their support points. These floor motions can be in the form of Floor Response Spectra (FRS) or the Floor Time Histories (FTH). In order to account for the various uncertainties in generating these floor motions, these motions should be peak broadened and smoothened as per the regulatory codes. Presented here in this paper is the methodology to account for such peak broadening effect in the FTH. Results of this study have been compared with the FRS approach and various important conclusions have been arrived at based on the study

  9. Transesophageal color Doppler evaluation of obstructive lesions using the new "Quasar" technology.

    Science.gov (United States)

    Fan, P; Nanda, N C; Gatewood, R P; Cape, E G; Yoganathan, A P

    1995-01-01

    Due to the unavoidable problem of aliasing, color flow signals from high blood flow velocities cannot be measured directly by conventional color Doppler. A new technology termed Quantitative Un-Aliased Speed Algorithm Recognition (Quasar) has been developed to overcome this limitation. Employing this technology, we used transesophageal color Doppler echocardiography to investigate whether the velocities detected by the Quasar would correlate with those obtained by continuous-wave Doppler both in vitro and in vivo. In the in vitro study, a 5.0 MHz transesophageal transducer of a Kontron Sigma 44 color Doppler flow system was used. Fourteen different peak velocities calculated and recorded by color Doppler-guided continuous-wave Doppler were randomly selected. In the clinical study, intraoperative transesophageal echocardiography was performed using the same transducer 18 adults (13 aortic valve stenosis, 2 aortic and 2 mitral stenosis, 2 hypertrophic obstructive cardiomyopathy and 1 mitral valve stenosis). Following each continuous-wave Doppler measurement, the Quasar was activated, and a small Quasar marker was placed in the brightest area of the color flow jet to obtain the maximum mean velocity readout. The maximum mean velocities measured by Quasar closely correlated with maximum peak velocities obtained by color flow guided continuous-wave Doppler in both in vitro (0.53 to 1.65 m/s, r = 0.99) and in vivo studies (1.50 to 6.01 m/s, r = 0.97). We conclude that the new Quasar technology can accurately measure high blood flow velocities during transesophageal color Doppler echocardiography. This technique has the potential of obviating the need for continuous-wave Doppler.

  10. Peak-Broadening of Floor Response Spectra for Base Isolated Nuclear Structures

    International Nuclear Information System (INIS)

    Ju, Heekun; Choun, Young-Sun; Kim, Min-Kyu

    2015-01-01

    In this paper, uncertainties in developing FRS are explained first. Then FDRS of a fixed structure is computed using a conventional method as an example. Lastly FRS of a base-isolated structure is computed and suitability of current peak-broadening method is examined. Uncertainties in the material property of structure influence FRS of fixed structures significantly, but their effect on FRS of base-isolated structures is negligible. Nuclear structures should be designed to ensure the safety of equipment and components mounted on their floors. However, coupled analysis of a structure and components is complex, so equipment is separately analyzed using floor response spectra (FRS). FRS calculated from dynamic analysis of structural model should be modified to create floor design response spectra (FDRS), the input for seismic design of equipment. For nuclear structures, smoothing and broadening peaks of FRS is required to account for uncertainties owing to material properties of structures, soil, modeling techniques, and others. The peak broadening method proposed for fixed based structures may not be appropriate for base-isolated structures because of additional uncertainties in the property of isolation bearings. For base-isolated structures, mechanical property of isolator plays a dominant role on the change of FRS. As base-isolated nuclear plants should meet the ASCE provisions, uncertainty in the isolation system would be around 10%. For the base isolated 3-storied beam model with 2.5-sec isolation period, 6.9% of broadening ratio was enough for development of FDRS at the required variation condition. Also for the models with various isolation periods, less than 10% of broadening ratio was sufficient

  11. DOPPLER SIGNATURES OF THE ATMOSPHERIC CIRCULATION ON HOT JUPITERS

    International Nuclear Information System (INIS)

    Showman, Adam P.; Lewis, Nikole K.; Fortney, Jonathan J.; Shabram, Megan

    2013-01-01

    The meteorology of hot Jupiters has been characterized primarily with thermal measurements, but recent observations suggest the possibility of directly detecting the winds by observing the Doppler shift of spectral lines seen during transit. Motivated by these observations, we show how Doppler measurements can place powerful constraints on the meteorology. We show that the atmospheric circulation—and Doppler signature—of hot Jupiters splits into two regimes. Under weak stellar insolation, the day-night thermal forcing generates fast zonal jet streams from the interaction of atmospheric waves with the mean flow. In this regime, air along the terminator (as seen during transit) flows toward Earth in some regions and away from Earth in others, leading to a Doppler signature exhibiting superposed blueshifted and redshifted components. Under intense stellar insolation, however, the strong thermal forcing damps these planetary-scale waves, inhibiting their ability to generate jets. Strong frictional drag likewise damps these waves and inhibits jet formation. As a result, this second regime exhibits a circulation dominated by high-altitude, day-to-night airflow, leading to a predominantly blueshifted Doppler signature during transit. We present state-of-the-art circulation models including non-gray radiative transfer to quantify this regime shift and the resulting Doppler signatures; these models suggest that cool planets like GJ 436b lie in the first regime, HD 189733b is transitional, while planets hotter than HD 209458b lie in the second regime. Moreover, we show how the amplitude of the Doppler shifts constrains the strength of frictional drag in the upper atmospheres of hot Jupiters. If due to winds, the ∼2 km s –1 blueshift inferred on HD 209458b may require drag time constants as short as 10 4 -10 6 s, possibly the result of Lorentz-force braking on this planet's hot dayside.

  12. Doppler-musical instrument

    International Nuclear Information System (INIS)

    Sato, T.J.; Watanabe, N.

    2001-01-01

    We propose a possible ultra-high energy resolution backscattering spectrometer optimized to spallation neutron source. A combination of multi monochromator crystal and Doppler drive provides considerable neutron flux, together with the reasonable energy range -30 < E < 30 μeV, even when the ultra-high energy resolution of ΔE∼0.03 μeV is attained. (author)

  13. Doppler-musical instrument

    Energy Technology Data Exchange (ETDEWEB)

    Sato, T.J. [National Research Institute for Metals, Tsukuba, Ibaraki (Japan); Watanabe, N. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Shibata, K. [Institute for Materials Research, Tohoku Univ., Sendai, Miyagi (Japan)

    2001-03-01

    We propose a possible ultra-high energy resolution backscattering spectrometer optimized to spallation neutron source. A combination of multi monochromator crystal and Doppler drive provides considerable neutron flux, together with the reasonable energy range -30 < E < 30 {mu}eV, even when the ultra-high energy resolution of {delta}E{approx}0.03 {mu}eV is attained. (author)

  14. Defect identification using positrons

    International Nuclear Information System (INIS)

    Beling, C.D.; Fung, S.

    2001-01-01

    The current use of the lifetime and Doppler broadening techniques in defect identification is demonstrated with two studies, the first being the identification of carbon vacancy in n-6H SiC through lifetime spectroscopy, and the second the production of de-hydrogenated voids in α-Si:H through light soaking. Some less conventional ideas are presented for more specific defect identification, namely (i) the amalgamation of lifetime and Doppler techniques with conventional deep level transient spectroscopy in what may be called ''positron-deep level transient spectroscopy'', and (ii) the extraction of more spatial information on vacancy defects by means of what may be called ''Fourier transform Doppler broadening of annihilation radiation spectroscopy'' (orig.)

  15. Trans-skull ultrasonic Doppler system aided by fuzzy logic

    Science.gov (United States)

    Hata, Yutaka; Nakamura, Masato; Yagi, Naomi; Ishikawa, Tomomoto

    2012-06-01

    This paper describes a trans-skull ultrasonic Doppler system for measuring the blood flow direction in brain under skull. In this system, we use an ultrasonic array probe with the center frequency of 1.0 MHz. The system determines the fuzzy degree of blood flow by Doppler Effect, thereby it locates blood vessel. This Doppler Effect is examined by the center of gravity shift of the frequency magnitudes. In in-vitro experiment, a cow bone was employed as the skull, and three silicon tubes were done as blood vessels, and bubble in water as blood. We received the ultrasonic waves through a protein, the skull and silicon tubes in order. In the system, fuzzy degrees are determined with respect to the Doppler shift, amplitude of the waves and attenuation of the tissues. The fuzzy degrees of bone and blood direction are calculated by them. The experimental results showed that the system successfully visualized the skull and flow direction, compared with the location and flow direction of the phantom. Thus, it detected the flow direction by Doppler Effect under skull, and automatically extracted the region of skull and blood vessel.

  16. Spectroscopic Doppler analysis for visible-light optical coherence tomography

    Science.gov (United States)

    Shu, Xiao; Liu, Wenzhong; Duan, Lian; Zhang, Hao F.

    2017-12-01

    Retinal oxygen metabolic rate can be effectively measured by visible-light optical coherence tomography (vis-OCT), which simultaneously quantifies oxygen saturation and blood flow rate in retinal vessels through spectroscopic analysis and Doppler measurement, respectively. Doppler OCT relates phase variation between sequential A-lines to the axial flow velocity of the scattering medium. The detectable phase shift is between -π and π due to its periodicity, which limits the maximum measurable unambiguous velocity without phase unwrapping. Using shorter wavelengths, vis-OCT is more vulnerable to phase ambiguity since flow induced phase variation is linearly related to the center wavenumber of the probing light. We eliminated the need for phase unwrapping using spectroscopic Doppler analysis. We split the whole vis-OCT spectrum into a series of narrow subbands and reconstructed vis-OCT images to extract corresponding Doppler phase shifts in all the subbands. Then, we quantified flow velocity by analyzing subband-dependent phase shift using linear regression. In the phantom experiment, we showed that spectroscopic Doppler analysis extended the measurable absolute phase shift range without conducting phase unwrapping. We also tested this method to quantify retinal blood flow in rodents in vivo.

  17. A study of doppler waveform using pulsatile flow model

    International Nuclear Information System (INIS)

    Chung, Hye Won; Chung, Myung Jin; Park, Jae Hyung; Chung, Jin Wook; Lee, Dong Hyuk; Min, Byoung Goo

    1997-01-01

    Through the construction of a pulsatile flow model using an artificial heart pump and stenosis to demonstrate triphasic Doppler waveform, which simulates in vivo conditions, and to evaluate the relationship between Doppler waveform and vascular compliance. The flow model was constructed using a flowmeter, rubber tube, glass tube with stenosis, and artificial heart pump. Doppler study was carried out at the prestenotic, poststenotic, and distal segments;compliance was changed by changing the length of the rubber tube. With increasing proximal compliance, Doppler waveforms show decreasing peak velocity of the first phase and slightly delayed acceleration time, but the waveform itself did not change significantly. Distal compliance influenced the second phase, and was important for the formation of pulsus tardus and parvus, which without poststenotic vascular compliance, did not develop. The peak velocity of the first phase was inversely proportional to proximal compliance, and those of the second and third phases were directly proportional to distal compliance. After constructing this pulsatile flow model, we were able to explain the relationship between vascular compliance and Doppler waveform, and also better understand the formation of pulsus tardus and parvus

  18. Response of a Doppler canceling system to plane gravitational waves

    International Nuclear Information System (INIS)

    Caporali, A.

    1982-01-01

    This paper discusses the interaction of long periodic gravitational waves with a three-link microwave system known as the Doppler canceling system. This system, which was developed for gravitational red-shift experiment, uses one-way and two-way Doppler information to construct the beat signal of two reference oscillators moving with respect to each other. The geometric-optics approximation is used to derive the frequency shift produced on a light signal propagating in a gravitational-wave space-time. The signature left on the Doppler-canceled beat by bursts and continuous gravitational waves is analyzed. A comparison is made between the response to gravitational waves of the Doppler canceling system and that of a (NASA) Doppler tracking system which employs two-way, round-trip radio waves. A threefold repetition of the gravitational wave form is found to be a common feature of the response functions of both systems. These two functions otherwise exhibit interesting differences

  19. Micro-Doppler Ambiguity Resolution Based on Short-Time Compressed Sensing

    Directory of Open Access Journals (Sweden)

    Jing-bo Zhuang

    2015-01-01

    Full Text Available When using a long range radar (LRR to track a target with micromotion, the micro-Doppler embodied in the radar echoes may suffer from ambiguity problem. In this paper, we propose a novel method based on compressed sensing (CS to solve micro-Doppler ambiguity. According to the RIP requirement, a sparse probing pulse train with its transmitting time random is designed. After matched filtering, the slow-time echo signals of the micromotion target can be viewed as randomly sparse sampling of Doppler spectrum. Select several successive pulses to form a short-time window and the CS sensing matrix can be built according to the time stamps of these pulses. Then performing Orthogonal Matching Pursuit (OMP, the unambiguous micro-Doppler spectrum can be obtained. The proposed algorithm is verified using the echo signals generated according to the theoretical model and the signals with micro-Doppler signature produced using the commercial electromagnetic simulation software FEKO.

  20. Korea-China Joint R and D on Doppler Lidar Technology

    International Nuclear Information System (INIS)

    Cha, Hyung Ki; Kim, D. H.; Kwon, S. O.; Yang, K. H.; Song, I. K.

    2009-03-01

    Doppler lidar technology is to monitor atmospheric wind velocity by measuring the light scattering signals between a laser and aerosol particles or molecules existing in the atmosphere. When the particles (or molecules) in the atmosphere are moving by wind force, the frequency of backscattering light is shifted by doppler effect, so that the wind velocity profile can be obtained by measurement of the shifted frequencies. When the laser radiation is scanned in four different direction, three dimensional wind profiles are obtained. The Anhui Institute of Optics and Fine Mechanics under the China Academy of Sciences has developed and operated the doppler lidar system for long time. In this project we want to developed a new technologies adopted to the chinese doppler system and to test the updated In the process of collaboration between China and Korea research teams, we want to learn the state-of-art technology involved in the doppler lidar system

  1. Improvements to the ion Doppler spectrometer diagnostic on the HIT-SI experiments

    Science.gov (United States)

    Hossack, Aaron; Chandra, Rian; Everson, Chris; Jarboe, Tom

    2018-03-01

    An ion Doppler spectrometer diagnostic system measuring impurity ion temperature and velocity on the HIT-SI and HIT-SI3 spheromak devices has been improved with higher spatiotemporal resolution and lower error than previously described devices. Hardware and software improvements to the established technique have resulted in a record of 6.9 μs temporal and ≤2.8 cm spatial resolution in the midplane of each device. These allow Ciii and Oii flow, displacement, and temperature profiles to be observed simultaneously. With 72 fused-silica fiber channels in two independent bundles, and an f/8.5 Czerny-Turner spectrometer coupled to a video camera, frame rates of up to ten times the imposed magnetic perturbation frequency of 14.5 kHz were achieved in HIT-SI, viewing the upper half of the midplane. In HIT-SI3, frame rates of up to eight times the perturbation frequency were achieved viewing both halves of the midplane. Biorthogonal decomposition is used as a novel filtering tool, reducing uncertainty in ion temperature from ≲13 to ≲5 eV (with an instrument temperature of 8-16 eV) and uncertainty in velocity from ≲2 to ≲1 km/s. Doppler shift and broadening are calculated via the Levenberg-Marquardt algorithm, after which the errors in velocity and temperature are uniquely specified. Axisymmetric temperature profiles on HIT-SI3 for Ciii peaked near the inboard current separatrix at ≈40 eV are observed. Axisymmetric plasma displacement profiles have been measured on HIT-SI3, peaking at ≈6 cm at the outboard separatrix. Both profiles agree with the upper half of the midplane observable by HIT-SI. With its complete midplane view, HIT-SI3 has unambiguously extracted axisymmetric, toroidal current dependent rotation of up to 3 km/s. Analysis of the temporal phase of the displacement uncovers a coherent structure, locked to the applied perturbation. Previously described diagnostic systems could not achieve such results.

  2. The effectiveness of Doppler controlled hemorrhoidal artery ligation ...

    African Journals Online (AJOL)

    In this work, we discuss the preliminary results of the effectiveness of the hemorrhoidal artery ligation under control Doppler as a new technique for the treatment of hemorrhoids. We report the results of patients with hemorrhoids we have followed over a period of one year who were treated with HAL Doppler. The intra-and ...

  3. Digital nonlinearity compensation in high-capacity optical communication systems considering signal spectral broadening effect.

    Science.gov (United States)

    Xu, Tianhua; Karanov, Boris; Shevchenko, Nikita A; Lavery, Domaniç; Liga, Gabriele; Killey, Robert I; Bayvel, Polina

    2017-10-11

    Nyquist-spaced transmission and digital signal processing have proved effective in maximising the spectral efficiency and reach of optical communication systems. In these systems, Kerr nonlinearity determines the performance limits, and leads to spectral broadening of the signals propagating in the fibre. Although digital nonlinearity compensation was validated to be promising for mitigating Kerr nonlinearities, the impact of spectral broadening on nonlinearity compensation has never been quantified. In this paper, the performance of multi-channel digital back-propagation (MC-DBP) for compensating fibre nonlinearities in Nyquist-spaced optical communication systems is investigated, when the effect of signal spectral broadening is considered. It is found that accounting for the spectral broadening effect is crucial for achieving the best performance of DBP in both single-channel and multi-channel communication systems, independent of modulation formats used. For multi-channel systems, the degradation of DBP performance due to neglecting the spectral broadening effect in the compensation is more significant for outer channels. Our work also quantified the minimum bandwidths of optical receivers and signal processing devices to ensure the optimal compensation of deterministic nonlinear distortions.

  4. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young [Dept. of Radiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  5. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Directory of Open Access Journals (Sweden)

    Ji Young Hwang

    2017-04-01

    Full Text Available Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  6. Studies of solar flares: Homology and X-ray line broadening

    Science.gov (United States)

    Ranns, Neale David Raymond

    This thesis starts with an introduction to the solar atmosphere and the physics that governs its behaviour. The formation processes of spectral lines are presented followed by an explanation of employed plasma diagnostic techniques and line broadening mechanisms. The current understanding on some principle concepts of flare physics are reviewed and the topics of flare homology and non-thermal line broadening are introduced. The many solar satellites and instrumentation that were utilised during this thesis are described. Analysis techniques for some instruments are also presented. A series of solar flares that conform to the literature definition for homologous flares are examined. The apparent homology is shown to be caused by emerging flux rather than continual stressing of a single, or group of, magnetic structure's. The implications for flare homology are discussed. The analysis of a solar flare with a rise and peak in the observed non-thermal X-ray line broadening (Vnt) is then performed. The location of the hot plasma within the flare area is determined and consequently the source of Vnt is located to be within and above the flare loops. The flare footpoints are therefore discarded as a possible source location. Viable source locations are discussed with a view to determining the dominant mechanism for the generation of line broadening. The timing relationships between the hard X-ray (HXR) flux and Vnt in many solar flares are then examined. I show that there is a causal relationship between these two parameters and that the HXR rise time is related to the time delay between the maxima of HXR flux and Vnt. The temporal evolution of Vnt is shown to be dependent upon the shape of the HXR burst. The implications of these results are discussed in terms of determining the line broadening mechanism and the limitations of the data. A summary of the results in this thesis is then presented together with suggestions for future research.

  7. Lorentz invariance and the rotor Doppler shift experiments

    International Nuclear Information System (INIS)

    Rodrigues Junior, W.A.; Tiomno, J.

    1984-01-01

    It is shown that 'Rotor Doppler shift Experiments' provide a way to distinguish Einstein's Special Relativity (SR) from Lorentz's Aether Theory (LAT). Misconceptions in previous papers involving the Doppler shift experiments are examined. The theoretical and experimental data available on rotor Doppler shift experiments are analysed. Two models of SR violating theories are used to predict the output of a recently proposed experiment by Torr and Kolen. The first one corresponds to (strict) LAT and the other to an extended form of LAT Contrary to the first, the second theory leads to results in agreement with the preliminary experimental data of Torr et al indicating a breakdown both of SR and strict LAT. (Author) [pt

  8. Lorentz invariance and the rotor Doppler shift experiments

    International Nuclear Information System (INIS)

    Rodrigues Junior, W.A.; Tiomno, J.

    1984-01-01

    It is shown that 'Rotor Doppler shift Experiments' provide a way to distinguish Einstein's Special Relativity (SR) from Lorentz's Aether Theory (LAT). Misconceptions in previous papers involving the Doppler shift experiments are examined. The theoretical and experimental data available on rotor Doppler shift experiments are analysed. Two models of SR violating theories are used to predict the output of a recently proposed experiment by Torr and Kolen. The first one corresponds to (strict) LAT and the other to an extended form of LAT. Contrary to the first, the second theory leads to results in agreement with the preliminary experimental data of Torr et al indicating a breakdown both of SR and strict LAT. (Author) [pt

  9. ISAR imaging using the instantaneous range instantaneous Doppler method

    CSIR Research Space (South Africa)

    Wazna, TM

    2015-10-01

    Full Text Available In Inverse Synthetic Aperture Radar (ISAR) imaging, the Range Instantaneous Doppler (RID) method is used to compensate for the nonuniform rotational motion of the target that degrades the Doppler resolution of the ISAR image. The Instantaneous Range...

  10. Análisis de perforantes de la epigástrica inferior profunda con Angio TC 3D, Eco Doppler color y Doppler simple de ultrasonidos en colgajo DIEP: resultados preliminares Analysis of deep inferior epigastric perforating vessels with 3D CT angiography, color Doppler ultrasonography and Doppler in diep flaps: preliminary results

    Directory of Open Access Journals (Sweden)

    J. Castro García

    2008-09-01

    Full Text Available Nuestro objetivo es la validación de la Angio TC tridimensional como herramienta de planificación de los colgajos DIEP, comparándolo con el Doppler de ultrasonidos (US y eco Doppler color. Entre enero de 2006 y marzo de 2007 se realiza en 11 pacientes (13 DIEP un estudio comparativo prospectivo entre el Doppler de US, eco Doppler color y Angio TC con reconstrucción tridimensional, utilizando como dato de referencia los hallazgos intraoperatorios. En dicho proceso se localiza la mejor perforante que pueda servir como pedículo al colgajo DIEP en función de su localización, calibre, trayecto y relaciones anatómicas con respecto al músculo. La Angio TC con reconstrucción tridimensional, demuestra una especificidad del 100% (IC 95% 75.3-100 lo que le convierte en una prueba con un alto valor predictivo positivo y una excelente herramienta en la planificación de los colgajos de perforantes. El eco Doppler color determinó, que tan sólo en un 46,1% (IC 95% 19,2-74,9 de los pacientes, la perforante seleccionada por la prueba de forma preoperatoria, coincidía con la perforante elegida en quirófano. Con el Doppler de US, en un 30,8 % (IC 95% 9,1-61,4 de los colgajos estudiados, coincidía la mejor perforante escogida de forma preoperatoria, con los hallazgos obtenidos tras la disección del colgajo. En el presente estudio, la Angio TC tridimensional se ha mostrado como una técnica con una gran especificidad que proporciona valiosa información, sólo comparable con la disección anatómica y por delante de pruebas como el Doppler de ultrasonidos y el eco Doppler color.The aim of this report, is to validate the Angio-CT technique with three-dimentional reconstruction as a preoperative planning tool, after comparison with Doppler ultrasound and color- Duplex. Between january 2006 and march 2007, we studied 11 consecutive patients (13 DIEP in whom a prospective comparative followed up was performed comparing, the findings observed using

  11. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  12. Three-dimensional power Doppler sonography in screening for carotid artery disease.

    Science.gov (United States)

    Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D

    2000-01-01

    Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.

  13. Time sequence spectroscopy of AW UMa. The 518 nm Mg I triplet region analyzed with broadening functions

    International Nuclear Information System (INIS)

    Rucinski, Slavek M.

    2015-01-01

    High-resolution spectroscopic observations of AW UMa, obtained on three consecutive nights with a median time resolution of 2.1 minutes, have been analyzed using the broadening function method in the spectral window of 22.75 nm around the 518 nm Mg i triplet region. Doppler images of the system reveal the presence of vigorous mass motions within the binary system; their presence puts into question the solid-body rotation assumption of the contact binary model. AW UMa appears to be a very tight, semi-detached binary; the mass transfer takes place from the more massive to the less massive component. The primary, a fast-rotating star with Vsini=181.4±2.5 km s −1 , is covered with inhomogeneities: very slowly drifting spots and a dense network of ripples more closely participating in its rotation. The spectral lines of the primary show an additional broadening component (called the “pedestal”) that originates either in the equatorial regions, which rotate faster than the rest of the star by about 50 km s −1 , or in an external disk-like structure. The secondary component appears to be smaller than predicted by the contact model. The radial velocity field around the secondary is dominated by accretion of matter transferred from (and possibly partly returned to) the primary component. The parameters of the binary are Asini=2.73±0.11 R ⊙ and M 1 sin 3 i=1.29±0.15 M ⊙ , M 2 sin 3 i=0.128±0.016 M ⊙ . The mass ratio, q sp =M 2 /M 1 =0.099±0.003, while still the most uncertain among the spectroscopic elements, is substantially different from the previous numerous and mutually consistent photometric investigations which were based on the contact model. It should be studied why photometry and spectroscopy give such discrepant results and whether AW UMa is an unusual object or if only very high-quality spectroscopy can reveal the true nature of W UMa-type binaries.

  14. A new formulation for resonance self-shielding factors

    Energy Technology Data Exchange (ETDEWEB)

    Palma, Daniel A.P.; Martinez, Aquilino S.; Silva, Fernando C. da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mail: aquilino@lmp.ufrj.br

    2007-07-01

    The activation technique allows either absolute or relative very precise neutron intensity measurements. This technique requires the knowledge of the Doppler broadening function to determine resonance self-shielding factors. In the present work a new formulation is proposed for the self-shielding factors where the Doppler broadening function is calculated using the Frobenius's method and compared to the values obtained from the four-pole Pade method. This calculation method is shown to be effective from the point of view of accuracy. (author)

  15. Doppler electron velocimetry : notes on creating a practical tool.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.; Milster, Tom (University of Arizona)

    2008-11-01

    The Doppler electron velocimeter (DEV) has been shown to be theoretically possible. This report attempts to answer the next logical question: Is it a practical instrument? The answer hinges upon whether enough electrons are available to create a time-varying Doppler current to be measured by a detector with enough sensitivity and bandwidth. The answer to both of these questions is a qualified yes. A target Doppler frequency of 1 MHz was set as a minimum rate of interest. At this target a theoretical beam current signal-to-noise ratio of 25-to-1 is shown for existing electron holography equipment. A detector is also demonstrated with a bandwidth of 1-MHz at a current of 10 pA. Additionally, a Linnik-type interferometer that would increase the available beam current is shown that would offer a more flexible arrangement for Doppler electron measurements over the traditional biprism.

  16. Spectral broadening of acoustic tones generated by unmanned aerial vehicles in a turbulent atmosphere

    DEFF Research Database (Denmark)

    Ostashev, Vladimir E.; Wilson, D. K.; Finn, Anthony

    2016-01-01

    The acoustic spectrum emitted by unmanned aerial vehicles (UAVs) and other aircraft can be distorted by propagation through atmospheric turbulence. Since most UAVs are propeller-based, they generate a series of acoustic tones and harmonics. In this paper, spectral broadening of these tones due......, spectral broadening is calculated and analyzed for typical meteorological regimes of the atmospheric boundary layer and different flight trajectories of UAVs. Experimental results are presented and compared with theoretical predictions. Spectral broadening might also provide a means for remotely sensing...

  17. Micro-Doppler classification of riders and riderless horses

    Science.gov (United States)

    Tahmoush, David

    2014-05-01

    Micro-range Micro-Doppler can be used to isolate particular parts of the radar signature, and in this case we demonstrate the differences in the signature between a walking horse versus a walking horse with a rider. Using micro-range micro-Doppler, we can distinguish the radar returns from the rider as separate from the radar returns of the horse.

  18. Color Doppler flow mapping of stenotic and regurgitant natural heart valves

    International Nuclear Information System (INIS)

    Nanda, N.C.

    1986-01-01

    Color Doppler echocardiography has found widest application in reliable detection and assessment of severity of both atrio-ventricular and semi-lunar valve incompetence. The authors believe both the sensitivity and specificity of color Doppler for the detection of mitral and aortic regurgitation is very high in patients with adequate acoustic windows. In 82 patients with proven mitral regurgitation studied, the best correlations with angiography were noted when the maximum or average regurgitant jet are obtained by color Doppler from three standard 2-D echo planes (parasternal long and short axis and apical four chamber view) and expressed as a percentage of the left atrial area were considered. The criteria the authors used for assessment of tricuspid and pulmonary valve incompetence are similar to those used for mitral and aortic valve incompetence, but the lack of a good ''gold'' standard has hampered validation. The color Doppler technique also supplements conventional Doppler in the assessment of severity of stenotic lesions by facilitating parallel alignment of the continuous wave Doppler cursor line with the stenotic jet for accurate recording of maximal velocities and pressure gradients. The authors have found this method especially useful in the assessment of aortic stenosis. In conclusion, color Doppler flow mapping combined with conventional echocardiography provides, for the first time, a comprehensive noninvasive assessement of the severity of regurgitant and stenotic lesions

  19. Self-pulsing and chaos in inhomogeneously broadened single mode lasers

    Energy Technology Data Exchange (ETDEWEB)

    Graham, R; Cho, Y

    1983-08-01

    A four-dimensional model and a six-dimensional model describing the self-pulsing instabilities and chaotic dynamics of inhomogeneously broadened single-mode lasers are derived as the first two steps of an infinite hierarchy of approximations increasing in accuracy and complexity. The results of a linear stability analysis of the time-independent states and some numerical solutions are given to show the various types of dynamic behavior which can occur in these models. The dynamic behavior is found to be much more complex than in the homogeneously broadened case and is obtained under physically more realistic conditions. 10 references.

  20. Comparison of the Diagnostic Performance of Power Doppler Ultrasound and a New Microvascular Doppler Ultrasound Technique (AngioPLUS) for Differentiating Benign and Malignant Breast Masses.

    Science.gov (United States)

    Jung, Hae Kyoung; Park, Ah Young; Ko, Kyung Hee; Koh, Jieun

    2018-03-12

    This study was performed to compare the diagnostic performance of power Doppler ultrasound (US) and a new microvascular Doppler US technique (AngioPLUS; SuperSonic Imagine, Aix-en-Provence, France) for differentiating benign and malignant breast masses. Power Doppler US and AngioPLUS findings were available in 124 breast masses with confirmed pathologic results (benign, 80 [64.5%]; malignant, 44 [35.5%]). The diagnostic performance of each tool was calculated to distinguish benign from malignant masses using a receiver operating characteristic curve analysis and compared. The area under the curve showed that AngioPLUS was superior to power Doppler US in differentiating benign from malignant breast masses, but the difference was not statistically significant. © 2018 by the American Institute of Ultrasound in Medicine.

  1. Resonance broadening of Hg lines as a density diagnostic in high intensity discharge lamps

    International Nuclear Information System (INIS)

    Lawler, J E

    2004-01-01

    The use of width measurements on resonance broadened lines of Hg as a density diagnostic in high intensity discharge (HID) lamps is reviewed and further developed in this paper. Optical depths of Hg I lines at 491.6 nm, 577.0 nm, and 1014 nm are computed as a function of temperature to confirm that these lines are optically thin in most HID lamps. The effect of quadratic and quartic radial temperature variation on the width of resonance broadened lines is computed for arc core temperatures from 4000 K to 7000 K. Such variations in temperature, and inverse variations in Hg density, are found to increase the line widths by less than 10% for 'side-on' emission measurements averaged over the arc radius. Theoretical profiles of resonance broadened spectral lines, both radially averaged and as a function of chord offset, are presented. Observations of resonance broadened lines in a metal-halide HID lamp are presented and analysed. It is concluded that the widths of resonance broadened lines provide a convenient and reliable diagnostic for the arc core Hg density but are generally not very sensitive to the radial temperature and Hg density gradient

  2. Acute Effects of Lateral Thigh Foam Rolling on Arterial Tissue Perfusion Determined by Spectral Doppler and Power Doppler Ultrasound.

    Science.gov (United States)

    Hotfiel, Thilo; Swoboda, Bernd; Krinner, Sebastian; Grim, Casper; Engelhardt, Martin; Uder, Michael; Heiss, Rafael U

    2017-04-01

    Hotfiel, T, Swoboda, B, Krinner, S, Grim, C, Engelhardt, M, Uder, M, and Heiss, R. Acute effects of lateral thigh foam rolling on arterial tissue perfusion determined by spectral Doppler and power Doppler ultrasound. J Strength Cond Res 31(4): 893-900, 2017-Foam rolling has been developed as a popular intervention in training and rehabilitation. However, evidence on its effects on the cellular and physiological level is lacking. The aim of this study was to assess the effect of foam rolling on arterial blood flow of the lateral thigh. Twenty-one healthy participants (age, 25 ± 2 years; height, 177 ± 9 cm; body weight, 74 ± 9 kg) were recruited from the medical and sports faculty. Arterial tissue perfusion was determined by spectral Doppler and power Doppler ultrasound, represented as peak flow (Vmax), time average velocity maximum (TAMx), time average velocity mean (TAMn), and resistive index (RI), and with semiquantitative grading that was assessed by 4 blindfolded investigators. Measurement values were assessed under resting conditions and twice after foam rolling exercises of the lateral thigh (0 and 30 minutes after intervention). The trochanteric region, mid portion, and distal tibial insertion of the lateral thigh were representative for data analysis. Arterial blood flow of the lateral thigh increased significantly after foam rolling exercises compared with baseline (p ≤ 0.05). We detected a relative increase in Vmax of 73.6% (0 minutes) and 52.7% (30 minutes) (p power Doppler scores at all portions revealed increased average grading of 1.96 after intervention and 2.04 after 30 minutes compared with 0.75 at baseline. Our results may contribute to the understanding of local physiological reactions to self-myofascial release.

  3. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Science.gov (United States)

    2010-04-01

    ... system. (a) Identification. An ultrasonic pulsed doppler imaging system is a device that combines the... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550... include signal analysis and display equipment, patient and equipment supports, component parts, and...

  4. Noise Studies of Externally Dispersed Interferometry for Doppler Velocimetry

    International Nuclear Information System (INIS)

    Erskine, D J; Edelstein, J; Lloyd, J; Muirhead, P

    2006-01-01

    Externally Dispersed Interferometry (EDI) is the series combination of a fixed-delay field-widened Michelson interferometer with a dispersive spectrograph. This combination boosts the spectrograph performance for both Doppler velocimetry and high resolution spectroscopy. The interferometer creates a periodic comb that multiplies against the input spectrum to create moire fringes, which are recorded in combination with the regular spectrum. Both regular and high-frequency spectral components can be recovered from the data--the moire component carries additional information that increases the signal to noise for velocimetry and spectroscopy. Here we present simulations and theoretical studies of the photon limited Doppler velocity noise in an EDI. We used a model spectrum of a 1600K temperature star. For several rotational blurring velocities 0, 7.5, 15 and 25 km/s we calculated the dimensionless Doppler quality index (Q) versus wavenumber v. This is the normalized RMS of the derivative of the spectrum and is proportional to the photon-limited Doppler signal to noise ratio

  5. Applications of Doppler in the first trimester

    International Nuclear Information System (INIS)

    Taylor, K.J.W.; Ramirez, B.; Grannum, P.

    1986-01-01

    Fifty patients have been studied by duplex Doppler US imaging in the first trimester. In normal gestations, luteal flow, characterized by a low pulsatility index (PI), can be seen in at least one ovary. Failure to detect luteal flow indicates a nonviable pregnancy. Six ectopic pregnancies demonstrated luteal flow and extrauterine heartbeat, detected by Doppler US. High PI values in the uterine artery are seen in the first trimester. Low PI values in the uterine arteries were found in patients with trophoblastic disease

  6. Christian Andreas Doppler--the man and his legacy.

    Science.gov (United States)

    Coman, I M

    2005-01-01

    Reminding the life and legacy of the Austrian Scientist who discovered the famous 'Doppler Effect'. C.A. Doppler was born the 29th of November 1803 in Salzburg. After studies in Linz and Vienna, he graduated in mathematics, became assistant at the University and later worked as a professor in Prague. Back to Vienna, he was appointed as professor at the Polytechnic School and --in 1850--as first director of the new Institute of Physics. C.A. Doppler did publish on magnetism, electricity, optics, and astronomy. He remains in the history of science due to the discovery presented (May 25, 1842) at the Royal Bohemian Society of Science entitled "On the colored light of the double stars and certain other stars of the heavens"; the paper described (applied to light) the shift of frequency which bears nowadays his name. The theory was later experimentally proven and--extended for any electromagnetic and acoustic waves--got myriads if applications in astronomy, physics, aviation, meteorology, and health science. Satomura in Japan (1955) published it's first ultrasound vascular application--with successive achievements in the next decades. Doppler ultrasonagraphy became the main noninvasive instrument for functional assesment of heart and vessels.

  7. Fetal Cardiac Doppler Signal Processing Techniques: Challenges and Future Research Directions

    Directory of Open Access Journals (Sweden)

    Saeed Abdulrahman Alnuaimi

    2017-12-01

    Full Text Available The fetal Doppler Ultrasound (DUS is commonly used for monitoring fetal heart rate and can also be used for identifying the event timings of fetal cardiac valve motions. In early-stage fetuses, the detected Doppler signal suffers from noise and signal loss due to the fetal movements and changing fetal location during the measurement procedure. The fetal cardiac intervals, which can be estimated by measuring the fetal cardiac event timings, are the most important markers of fetal development and well-being. To advance DUS-based fetal monitoring methods, several powerful and well-advanced signal processing and machine learning methods have recently been developed. This review provides an overview of the existing techniques used in fetal cardiac activity monitoring and a comprehensive survey on fetal cardiac Doppler signal processing frameworks. The review is structured with a focus on their shortcomings and advantages, which helps in understanding fetal Doppler cardiogram signal processing methods and the related Doppler signal analysis procedures by providing valuable clinical information. Finally, a set of recommendations are suggested for future research directions and the use of fetal cardiac Doppler signal analysis, processing, and modeling to address the underlying challenges.

  8. Doppler sonographic evaluation of ophthalmic arterial flow pattern in hypertensive patients

    International Nuclear Information System (INIS)

    Ryu, Dae Sik; Kim, Young Goo

    1994-01-01

    To compare the Doppler velocity waveform pattern of ophthalmic artery of hypertensive patients with that of normotensive subjects. Doppler velocity waveform was obtained from ophthalmic artery in 45 hypertensive patients and 60 normotensive subjects. Both hypertensives and normotensive subjects were classified according to age into those younger than and those older than 45 years. Doppler indices(pulsatility index(PI), resistance index(RI), the first systolic peak/the second systolic peak(S1/S2), the first systolic peak/diastolic peak(S1/D)) measured in hypertensive patients were compared with normotensive subjects. Among the various doppler indices, only S1/S2 showed significant difference(P < 0.05) between the hypertensive patients and normotensive subjects younger than 45 years. Doppler velocity waveform of hypertensive patients older than 45 years showed no significant difference from that of normotensive subjects with corresponding age. Doppler velocity waveform of ophthalmic artery in hypertensive patients younger than 45 years shows pattern with S2 higher than that of normotensive subjects. High S2 component(reflective-wave) may represent increased vascular impedance due to vasococonstriction of retinal arterioles in hypertensive patients

  9. Magnetic angioresonance of the carotid artery: correlation with color Doppler ultrasound

    International Nuclear Information System (INIS)

    Cotilla, J.; Miralles, M.; Cairols, M.C.; Dolz, J.L.; Vilanova, J.C.; Capdevila, A.

    1998-01-01

    To determine the value of magnetic angioresonance (MAR) in grading carotid stenosis, comparing it with color Doppler and intraarterial digital subtraction angiography (IADSA). A comparative study using color Doppler and MAR was carried out in 84 patients with coratid lesions. Fifty-two of the patients underwent angiographic study as well. The comparison of MAR versus arteriography in discriminating stenosis of more than 70%, expressed in terms of sensitivity specificity, overall precision and the kappa concordance index, gave values of 87.2, 90.8, 89.4 and 0.78%, respectively. When MAR was compared with color Doppler, the results were 86.8, 85.9, 86.3 and 0.72%, respectively. The results of the comparison between color Doppler and arteriography were 82.2, 86.2, 84.6 and 0.68%, respectively. The better correlation of MAR, as compares with angiography and color Doppler, with the grade of carotid stenosis indicates the high degree of reliability. The better correlation of MAR, as compares with angiography and color Doppler, with the grade of carotid stenosis indicates the high degree of reliability of this imaging technique. (Author) 29 refs

  10. Use of TRIGA-pulsed irradiations for high-temperature Doppler measurements

    Energy Technology Data Exchange (ETDEWEB)

    Foell, W K; Cashwell, R J; Bhattacharyya, S K [Argonne National Laboratory, Argonne, IL (United States); Russell, G J [Los Alamos Scientific Laboratory, University of California, Los Alamos, NM (United States)

    1974-07-01

    Conventional activation and reactivity measurements of the nuclear Doppler Effect have been limited to temperatures of about 2000{sup o}K because of problems with furnace equipment. There is a need for Doppler data at higher temperatures for design of reactors and analysis of reactor accidents. To fill this need, a novel technique using pulsed-mode operation of a TRIGA reactor has been developed at the University of Wisconsin. This new method, the Pulsed Activation Doppler (PAD) technique, has been used successfully for high temperature Doppler measurements of UO{sub 2} fuel pellets. In the PAD technique, UO{sub 2} test pellets were doped with varying amounts of U-235, with fissile enrichments varying from 0.22% to 12% by weight. The pellets were encapsulated in individual irradiation cells and electrically preheated to predetermined temperatures. Pyrofoam-graphite heaters were used to give preheat temperatures of up to 1720 deg. K. The cells were then positioned in the University of Wisconsin TRIGA reactor core and pulse-irradiated. During the rapid irradiation, adiabatic fission energy deposition occurred in the pellets and very high temperatures (over 3115 deg, K) were attained. Corresponding resonance neutron captures occurred at the elevated temperatures. The Doppler Ratio was deduced from the gamma activities of the Np-239 in the heated and unheated reference pellets. UO{sub 2} pellets of two nominal diameters, 210 mils (a surface-to-mass ratio, s/m = 1.1 cm{sup 2} /gm) and 360 mils (s/m = 0.63 cm{sup 2}/gm), were used for the experiments. For the 210 mil diameter pellets there was very good agreement between experimental results and Doppler ratios predicted both from extrapolations of the Hellstrand low-temperature resonance integral correlations and from GAROL calculations. Significantly, the agreement was good even for those pellets which experienced extensive melting. For the 360 mil diameter pellets the theoretical predictions were 10-15% lower than

  11. Doppler ultrasound scan during normal gestation: umbilical circulation

    International Nuclear Information System (INIS)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J.

    2002-01-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs

  12. Dispersed single-phase-step Michelson interferometer for Doppler imaging using sunlight.

    Science.gov (United States)

    Wan, Xiaoke; Ge, Jian

    2012-09-15

    A Michelson interferometer is dispersed with a fiber array-fed spectrograph, providing 59 Doppler sensing channels using sunlight in the 510-570 nm wavelength region. The interferometer operates at a single-phase-step mode, which is particularly advantageous in multiplexing and data processing compared to the phase-stepping mode of other interferometer spectrometer instruments. Spectral templates are prepared using a standard solar spectrum and simulated interferometer modulations, such that the correlation function with a measured 1D spectrum determines the Doppler shift. Doppler imaging of a rotating cylinder is demonstrated. The average Doppler sensitivity is ~12 m/s, with some channels reaching ~5 m/s.

  13. An elementary approach to the gravitational Doppler shift

    International Nuclear Information System (INIS)

    Wörner, C H; Rojas, Roberto

    2017-01-01

    In college physics courses, treatment of the Doppler effect is usually done far from the first introduction to kinematics. This paper aims to apply a graphical treatment to describe the gravitational redshift, by considering the Doppler effect in two accelerated reference frames and exercising the equivalence principle. This approach seems appropriate to discuss with beginner students and could serve to enrich the didactic processes. (paper)

  14. Collisional broadening of depolarized spectral lines of hydrogen gases at low temperatures

    International Nuclear Information System (INIS)

    Hout, K.D. van den.

    1978-01-01

    Experimental results are presented for the collisional broadening and shift of H 2 , D 2 and HD rotational Raman and depolarized Rayleigh lines at various temperatures between 25 K and 300 K. These are then discussed within the context of current theoretical concepts. For a few temperatures the line broadening cross sections are also reported as a function of the ortho-para composition for H 2 and D 2 . (C.F.)

  15. Saturation broadening effect in an InP photonic-crystal nanocavity switch

    DEFF Research Database (Denmark)

    Yu, Yi; Palushani, Evarist; Heuck, Mikkel

    2014-01-01

    Pump-probe measurements on InP photonic-crystal nanocavities show large-contrast fast switching at low pulse energy. For large pulse energies, large resonance shifts passing across the probe lead to switching contrast saturation and switching time-window broadening. © 2014 OSA.......Pump-probe measurements on InP photonic-crystal nanocavities show large-contrast fast switching at low pulse energy. For large pulse energies, large resonance shifts passing across the probe lead to switching contrast saturation and switching time-window broadening. © 2014 OSA....

  16. Search for Magnetically Broadened Cascade Emission from Blazars with VERITAS

    Energy Technology Data Exchange (ETDEWEB)

    Archambault, S.; Griffin, S. [Physics Department, McGill University, Montreal, QC H3A 2T8 (Canada); Archer, A.; Bugaev, V. [Department of Physics, Washington University, St. Louis, MO 63130 (United States); Benbow, W.; Cerruti, M. [Fred Lawrence Whipple Observatory, Harvard-Smithsonian Center for Astrophysics, Amado, AZ 85645 (United States); Buchovecky, M. [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States); Connolly, M. P. [School of Physics, National University of Ireland Galway, University Road, Galway (Ireland); Cui, W.; Finley, J. P. [Department of Physics and Astronomy, Purdue University, West Lafayette, IN 47907 (United States); Falcone, A. [Department of Astronomy and Astrophysics, 525 Davey Lab, Pennsylvania State University, University Park, PA 16802 (United States); Alonso, M. Fernández [Instituto de Astronomía y Física del Espacio (IAFE, CONICET-UBA), CC 67—Suc. 28, (C1428ZAA) Ciudad Autónoma de Buenos Aires (Argentina); Fleischhack, H.; Hütten, M. [DESY, Platanenallee 6, D-15738 Zeuthen (Germany); Fortson, L. [School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 55455 (United States); Furniss, A. [Department of Physics, California State University—East Bay, Hayward, CA 94542 (United States); Hervet, O.; Johnson, C. A. [Santa Cruz Institute for Particle Physics and Department of Physics, University of California, Santa Cruz, CA 95064 (United States); Holder, J. [Department of Physics and Astronomy and the Bartol Research Institute, University of Delaware, Newark, DE 19716 (United States); Humensky, T. B., E-mail: elisa.pueschel@ucd.ie, E-mail: weisgarber@physics.wisc.edu [Physics Department, Columbia University, New York, NY 10027 (United States); and others

    2017-02-01

    We present a search for magnetically broadened gamma-ray emission around active galactic nuclei (AGNs), using VERITAS observations of seven hard-spectrum blazars. A cascade process occurs when multi-TeV gamma-rays from an AGN interact with extragalactic background light (EBL) photons to produce electron–positron pairs, which then interact with cosmic microwave background photons via inverse-Compton scattering to produce gamma-rays. Due to the deflection of the electron–positron pairs, a non-zero intergalactic magnetic field (IGMF) would potentially produce detectable effects on the angular distribution of the cascade emission. In particular, an angular broadening compared to the unscattered emission could occur. Through non-detection of angularly broadened emission from 1ES 1218+304, the source with the largest predicted cascade fraction, we exclude a range of IGMF strengths around 10{sup −14} G at the 95% confidence level. The extent of the exclusion range varies with the assumptions made about the intrinsic spectrum of 1ES 1218+304 and the EBL model used in the simulation of the cascade process. All of the sources are used to set limits on the flux due to extended emission.

  17. Ultrasound and Doppler examination capabilities in adult portal hypertension type definition

    Directory of Open Access Journals (Sweden)

    N. V. Tumanskaya

    2015-08-01

    Full Text Available Early portal hypertension type diagnostics is an ultimate factor concerning kind and tactics of treatment. Aim. To objectify ultrasound examination capabilities, portal hemodynamics were studied in 97 patients using impulse and color doppler. Methods and results. It was ascertained that impulse and color doppler examination allows to visualize portal vein and its branches’ structural abnormalities, define subhepatic and intrahepatic types of portal hypertension, find thrombosis and characterize its stages. In cirrhosis patients with portal hypertension, homogenous doppler signal was received from the portal vessels lumen, while signs of intraluminar pathology were seen in the case of thrombosis of portal vein. Conclusion. This means that ultrasound examination of portal vein and its branches with impulse and color doppler is informative, non invasive method, which helps to define stages of portal hypertension. Doppler ultrasonography doesn’t have negative effect of ionizing radiation and can be used for the repeated research in the dynamics of disease.

  18. Superimposed noninterfering probes to extend the capabilities of phase Doppler anemometry.

    Science.gov (United States)

    Onofri, Fabrice; Lenoble, Anne; Radev, Stefan

    2002-06-20

    We propose using multiple superimposed noninterfering probes (SNIPs) of the same wavelength but different beam angles to extend the capabilities of phase Doppler anemometry. When a particle is moving in a SNIP the Doppler signals that are produced exhibit multiple Doppler frequencies and phase shifts. The resolution of the measurements of particle size (i.e., by fringe spacing and Doppler frequency) increases with beam angle. Then, with the solution proposed, even with only two detectors several measurements of size can be obtained for the same particle with increasing resolution if we consider higher frequencies in the signal. Several optical solutions to produce SNIPs as well as a signal-processing algorithm to treat the multiple-frequency Doppler signals are proposed. Experimental validations of the sizing of spherical and cylindrical particles demonstrate the applicability of this technique for particle measurement. We believe that this new technique can be of great interest when high resolution of size, velocity, and even refractive index is required.

  19. Correlation between Spectral Index and Doppler Factor for a ...

    Indian Academy of Sciences (India)

    Abstract. Relativistic beaming effect is important for blazars. In a very recent work, γ-ray Doppler factors were calculated for a sample of Fermi blazars (Fan et al. 2013). In this work, we investigated the correlation between the Doppler factor and the effective spectral index, αOX, and found an anticorrelation between them.

  20. Technical Note: A new phantom design for routine testing of Doppler ultrasound.

    Science.gov (United States)

    Grice, J V; Pickens, D R; Price, R R

    2016-07-01

    The objective of this project is to demonstrate the principle and operation for a simple, inexpensive, and highly portable Doppler ultrasound quality assurance (QA) phantom intended for routine QA testing. A prototype phantom has been designed, fabricated, and evaluated. The phantom described here is powered by gravity alone, requires no external equipment for operation, and produces a stable fluid velocity useful for quality assurance. Many commercially available Doppler ultrasound testing systems can suffer from issues such as a lengthy setup, prohibitive cost, nonportable size, or difficulty in use. This new phantom design aims to address some of these problems and create a phantom appropriate for assessing Doppler ultrasound stability. The phantom was fabricated using a 3D printer. The basic design of the phantom is to provide gravity-powered flow of a Doppler fluid between two reservoirs. The printed components were connected with latex tubing and then seated in a tissue mimicking gel. Spectral Doppler waveforms were sampled to evaluate variations in the data, and the phantom was evaluated using high frame rate video to find an alternate measure of mean fluid velocity flowing in the phantom. The current system design maintains stable flow from one reservoir to the other for approximately 7 s. Color Doppler imaging of the phantom was found to be qualitatively consistent with laminar flow. Using pulsed spectral Doppler, the average fluid velocity from a sample volume approximately centered in the synthetic vessel was measured to be 56 cm/s with a standard deviation of 3.2 cm/s across 118 measurements. An independent measure of the average fluid velocity was measured to be 51.9 cm/s with a standard deviation of 0.7 cm/s over 4 measurements. The developed phantom provides stable fluid flow useful for frequent clinical Doppler ultrasound testing and attempts to address several obstacles facing Doppler phantom testing. Such an ultrasound phantom can make routine

  1. Assessment of ureterovesical jet dynamics in obstructed ureter by urinary stone with color Doppler and duplex Doppler examinations.

    Science.gov (United States)

    Jandaghi, Ali Babaei; Falahatkar, Siavash; Alizadeh, Ahmad; Kanafi, Alireza Rajabzadeh; Pourghorban, Ramin; Shekarchi, Babak; Zirak, Amin Keshavarz; Esmaeili, Samaneh

    2013-04-01

    This study was designed to evaluate ureterovesical jet dynamics in obstructed ureter and to compare it with those of contralateral unobstructed side. Forty-six patients with diagnosis of ureteral stone, based on imaging findings in computed tomography were enrolled in this study. The gray-scale ultrasound exam from both kidneys and urinary bladder was performed. Then, ureterovesical jet characteristics including ureteral jet frequency, duration and peak velocity were assessed by color Doppler and duplex Doppler studies in both obstructed and unobstructed ureters by a radiologist, 15-30 min after oral hydration with 750-1,000 mL of water. When compared with contralateral normal side, the ureterovesical jet in obstructed ureter showed less frequency (0.59 vs. 3.04 jets/min; P < 0.05), shorter duration (1.24 vs. 5.26 s; P < 0.05) and lower peak velocity (5.41 vs. 32.09 cm/s; P < 0.05). The cut-off points of 1.5 jets/min, 2.5 s and 19.5 cm/s for difference of ureteral jet frequency, duration and peak velocity between obstructed and contralateral normal ureters yielded sensitivities of 97.8, 95.6 and 100 % and specificities of 87, 87.9 and 97.8 %, respectively for diagnosis of ureteral obstruction. Given the safety of Doppler study and significant differences in flow dynamics of obstructed versus unobstructed ureters, our findings demonstrated the utility of Doppler ultrasound examination as a useful adjunct to gray-scale ultrasound by improving the accuracy of ultrasound exam in diagnosis of ureteral obstruction.

  2. Comparative analysis of pulsed doppler ultrasonography of portal vein vs indirect photography

    International Nuclear Information System (INIS)

    Chang, Jae Chun; Kwon, Huck Po; Hwang, Mi Soo; Kim, Sun Youn; Park, Bok Hwan; Lee, Hyun Ju; Kim, Hong Jin

    1990-01-01

    There are some limitation of interpretation in indirect photography via superior mesenteric artery. In order to supplement and predict indirect photography, we compared indirect photographic findings with pulsed doppler flowmetry in 38 hepatobiliary patients, and the results were as follow: 1. In case of normal main portal vein(MPV) filling, Pulsed Doppler always showed antegrade, continuous parabolic wave form and cases of abnormal MPV filling, showed unusual wave form and flow direction. 2. In normal filling case of proximal right portal vein, Pulsed Doppler almost showed normal continuous parabolic wave form but in normal filling cases of proximal left portal vein, occasionally showed undulating wave form. 3. In each side proximal portal vein abnormal filling case, we could observe abnormal doppler wave form and could obtain additional information using doppler wave form. 4. Mean portal flow velocity was significantly increased in higher photography grade(p=0.01) and congestion index was significantly decreased in higher photography grade(p=0.01). 5. We concluded that doppler ultrasonography could supplement incomplete indirect photography

  3. Color Doppler Ultrasonographic Findings of Vascular Leiomyoma: Pathologic Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Ji Young; Koh, Sung Hye; Min, Soo Kee; Choi, A Lam; Jang, Kyung Mi; Lee, Yul; Lee, Kwan Seop; Lee, Hyun; Sohn, Jeong Hee [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Kim, Sam Soo [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2009-12-15

    To evaluate the distribution of color flow signals on color Doppler ultrasonography of vascular leiomyomas and to correlate them with pathologic findings. We retrospectively analyzed color Doppler ultrasonographic images and pathologic slides of six vascular leiomyomas. We classified the patterns of distribution of color flow signals into localized compact cluster types and non-cluster types, and the pathologic findings into three subtypes: solid, venous and cavernous. All cases showed well-defined homogenous hypoechoic subcutaneous masses on gray-scale ultrasonography. Three cases showed localized compact cluster types on color Doppler ultrasonography, one in each subtype (solid, venous and cavernous). For the three non-cluster types, again there was on in each subtype. In addition, on pathologic analysis the zone of the localized compact cluster of color flow signals coincided with a cluster of larger, vascular caliber masses. Localized compact clusters of color flow signals on color Doppler ultrasonography were seen in 50% of our cases and correlated with a cluster of larger vascular caliber in the mass. But the pattern of distribution of color flows didn't show a correlation with pathologic type

  4. Color Doppler Ultrasonographic Findings of Vascular Leiomyoma: Pathologic Correlation

    International Nuclear Information System (INIS)

    Ko, Ji Young; Koh, Sung Hye; Min, Soo Kee; Choi, A Lam; Jang, Kyung Mi; Lee, Yul; Lee, Kwan Seop; Lee, Hyun; Sohn, Jeong Hee; Kim, Sam Soo

    2009-01-01

    To evaluate the distribution of color flow signals on color Doppler ultrasonography of vascular leiomyomas and to correlate them with pathologic findings. We retrospectively analyzed color Doppler ultrasonographic images and pathologic slides of six vascular leiomyomas. We classified the patterns of distribution of color flow signals into localized compact cluster types and non-cluster types, and the pathologic findings into three subtypes: solid, venous and cavernous. All cases showed well-defined homogenous hypoechoic subcutaneous masses on gray-scale ultrasonography. Three cases showed localized compact cluster types on color Doppler ultrasonography, one in each subtype (solid, venous and cavernous). For the three non-cluster types, again there was on in each subtype. In addition, on pathologic analysis the zone of the localized compact cluster of color flow signals coincided with a cluster of larger, vascular caliber masses. Localized compact clusters of color flow signals on color Doppler ultrasonography were seen in 50% of our cases and correlated with a cluster of larger vascular caliber in the mass. But the pattern of distribution of color flows didn't show a correlation with pathologic type

  5. Moving Target Detection With Compact Laser Doppler Radar

    Science.gov (United States)

    Sepp, G.; Breining, A.; Eisfeld, W.; Knopp, R.; Lill, E.; Wagner, D.

    1989-12-01

    This paper describes an experimental integrated optronic system for detection and tracking of moving objects. The system is based on a CO2 waveguide laser Doppler ra-dar with homodyne receiver and galvanometer mirror beam scanner. A "hot spot" seeker consisting of a thermal imager with image processor transmits the coordinates of IR-emitting, i.e. potentially powered, objects to the laser radar scanner. The scanner addresses these "hot" locations operating in a large field-of-view (FOV) random ac-cess mode. Hot spots exhibiting a Doppler shifted laser signal are indicated in the thermal image by velocity-to-colour encoded markers. After switching to a small FOV scanning mode, the laser Doppler radar is used to track fast moving objects. Labora-tory and field experiments with moving objects including rotating discs, automobiles and missiles are described.

  6. Three-dimensional laser cooling at the Doppler limit

    Science.gov (United States)

    Chang, R.; Hoendervanger, A. L.; Bouton, Q.; Fang, Y.; Klafka, T.; Audo, K.; Aspect, A.; Westbrook, C. I.; Clément, D.

    2014-12-01

    Many predictions of Doppler-cooling theory of two-level atoms have never been verified in a three-dimensional geometry, including the celebrated minimum achievable temperature ℏ Γ /2 kB , where Γ is the transition linewidth. Here we show that, despite their degenerate level structure, we can use helium-4 atoms to achieve a situation in which these predictions can be verified. We make measurements of atomic temperatures, magneto-optical trap sizes, and the sensitivity of optical molasses to a power imbalance in the laser beams, finding excellent agreement with Doppler theory. We show that the special properties of helium, particularly its small mass and narrow transition linewidth, prevent effective sub-Doppler cooling with red-detuned optical molasses. This discussion can be generalized to identify when a given species is likely to be subject to the same limitation.

  7. Color doppler ultrasound diagonosis in cesarean scar pregnancy

    International Nuclear Information System (INIS)

    Chen Shanshan; Xia Fei; Shen Zongji; Xu Jianyin; Gu Xinxian

    2010-01-01

    Objective: To study the sonographic characteristics of cesarean scar pregnancy(CSP), and the value of color Doppler in the diagnosis of CSP. Methods: Twelve cases of CSP were all confirmed by transabdominal and transvaginal ultrasound. Results: The ultrasonogram of CSP could be divided into gestational sac type and mixed mass type. Conclusion: Color Doppler can give guidance to the early diagnosis, treatment and following-up of CSP because of the sonographic specifity of CSP. (authors)

  8. Extensional-wave stopband broadening across the joint of pipes of different thickness.

    Science.gov (United States)

    Su, Yuanda; Tang, Xiaoming; Liu, Yukai; Xu, Song; Zhuang, Chunxi

    2015-11-01

    The stopband of pipe extensional waves is an interesting natural phenomenon. This study demonstrates an important extension of this phenomenon. That is, the stopband can be effectively broadened by transmitting the waves across the joint of pipes of different thickness. The theoretical and experimental results reveal the detailed process of stopband forming along the pipe and the band broadening across the pipe joint. The result can be utilized to provide a method for logging while drilling acoustic isolation design.

  9. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  10. [The value of Doppler sonography in the detection of fetal hypoxia].

    Science.gov (United States)

    Aranyosi, János; Zatik, János; Juhász, A Gábor; Fülesdi, Béla; Major, Tamás

    2002-10-27

    Doppler ultrasound has become a part of routine antenatal fetal surveillance during the past two decades. It provides insight into the utero-placental and fetal arterial, venous circulation non-invasively. Doppler examination has a key role in the detection of hypoxic risk since abnormal blood flow patterns can be demonstrated before the clinical manifestation of fetal disorder. Doppler velocimetry facilitates judgment in the diagnosis, monitoring fetal well-being during pregnancy and labor, scheduling antenatal tests and timing delivery. Authors review the effects of chronic and acute hypoxia on fetal hemodynamics. On the basis of the present knowledge and experience a brief summary is given about the role of Doppler velocimetry in the early detection of hypoxic fetal jeopardy during pregnancy and labor.

  11. Doppler Centroid Estimation for Airborne SAR Supported by POS and DEM

    Directory of Open Access Journals (Sweden)

    CHENG Chunquan

    2015-05-01

    Full Text Available It is difficult to estimate the Doppler frequency and modulating rate for airborne SAR by using traditional vector method due to instable flight and complex terrain. In this paper, it is qualitatively analyzed that the impacts of POS, DEM and their errors on airborne SAR Doppler parameters. Then an innovative vector method is presented based on the range-coplanarity equation to estimate the Doppler centroid taking the POS and DEM as auxiliary data. The effectiveness of the proposed method is validated and analyzed via the simulation experiments. The theoretical analysis and experimental results show that the method can be used to estimate the Doppler centroid with high accuracy even in the cases of high relief, instable flight, and large squint SAR.

  12. Doppler velocity measurements from large and small arteries of mice

    Science.gov (United States)

    Reddy, Anilkumar K.; Madala, Sridhar; Entman, Mark L.; Michael, Lloyd H.; Taffet, George E.

    2011-01-01

    With the growth of genetic engineering, mice have become increasingly common as models of human diseases, and this has stimulated the development of techniques to assess the murine cardiovascular system. Our group has developed nonimaging and dedicated Doppler techniques for measuring blood velocity in the large and small peripheral arteries of anesthetized mice. We translated technology originally designed for human vessels for use in smaller mouse vessels at higher heart rates by using higher ultrasonic frequencies, smaller transducers, and higher-speed signal processing. With these methods one can measure cardiac filling and ejection velocities, velocity pulse arrival times for determining pulse wave velocity, peripheral blood velocity and vessel wall motion waveforms, jet velocities for the calculation of the pressure drop across stenoses, and left main coronary velocity for the estimation of coronary flow reserve. These noninvasive methods are convenient and easy to apply, but care must be taken in interpreting measurements due to Doppler sample volume size and angle of incidence. Doppler methods have been used to characterize and evaluate numerous cardiovascular phenotypes in mice and have been particularly useful in evaluating the cardiac and vascular remodeling that occur following transverse aortic constriction. Although duplex ultrasonic echo-Doppler instruments are being applied to mice, dedicated Doppler systems are more suitable for some applications. The magnitudes and waveforms of blood velocities from both cardiac and peripheral sites are similar in mice and humans, such that much of what is learned using Doppler technology in mice may be translated back to humans. PMID:21572013

  13. LBQ2D, Extending the Line Broadened Quasilinear Model to TAE-EP Interaction

    Science.gov (United States)

    Ghantous, Katy; Gorelenkov, Nikolai; Berk, Herbert

    2012-10-01

    The line broadened quasilinear model was proposed and tested on the one dimensional electrostatic case of the bump on tailfootnotetextH.L Berk, B. Breizman and J. Fitzpatrick, Nucl. Fusion, 35:1661, 1995 to study the wave particle interaction. In conventional quasilinear theory, the sea of overlapping modes evolve with time as the particle distribution function self consistently undergo diffusion in phase space. The line broadened quasilinear model is an extension to the conventional theory in a way that allows treatment of isolated modes as well as overlapping modes by broadening the resonant line in phase space. This makes it possible to treat the evolution of modes self consistently from onset to saturation in either case. We describe here the model denoted by LBQ2D which is an extension of the proposed one dimensional line broadened quasilinear model to the case of TAEs interacting with energetic particles in two dimensional phase space, energy as well as canonical angular momentum. We study the saturation of isolated modes in various regimes and present the analytical derivation and numerical results. Finally, we present, using ITER parameters, the case where multiple modes overlap and describe the techniques used for the numerical treatment.

  14. Pulsed-wave transmitral Doppler do not diagnose moderate acute rejection after heart transplantation

    NARCIS (Netherlands)

    Mannaerts, H. F.; Simoons, M. L.; Balk, A. H.; Tijssen, J.; van der Borden, S. G.; Zondervan, P. E.; Mochtar, B.; Weimar, W.; Roelandt, J. R.

    1993-01-01

    The value of pulsed-wave transmitral Doppler for the diagnosis of moderate acute rejection was examined in a total of 347 Doppler recordings obtained in 32 consecutive cardiac allograft recipients. Serial Doppler examinations (median, 11 per patient; range, 1 to 23) were performed simultaneously

  15. PULSED-WAVE TRANSMITRAL DOPPLER DO NOT DIAGNOSE MODERATE ACUTE REJECTION AFTER HEART-TRANSPLANTATION

    NARCIS (Netherlands)

    MANNAERTS, HF; SIMOONS, ML; BALK, AH; TIJSSEN, J; VANDERBORDEN, SG; ZONDERVAN, PE; MOCHTAR, B; WEIMAR, W; ROELANDT, [No Value

    1993-01-01

    The value of pulsed-wave transmitral Doppler for the diagnosis of moderate acute rejection was examined in a total of 347 Doppler recordings obtained in 32 consecutive cardiac allograft recipients. Serial Doppler examinations (median, 11 per patient; range, 1 to 23) were performed simultaneously

  16. Pressure broadening measurement of submillimeter-wave lines of O3

    International Nuclear Information System (INIS)

    Yamada, M.M.; Amano, T.

    2005-01-01

    The pressure broadening coefficients and their temperature dependences for two submillimeter-wave transitions of ozone, one being monitored with Odin and the other to be monitored with JEM/SMILES and EOS-MLS, have been determined by using a BWO based submillimeter-wave spectrometer. The measurements have also been extended to one of the symmetric isotopic species, 16 O 18 O 16 O. The isotopic species is observed in natural abundance and as a consequence the temperature dependence is not determined due to weak signal intensity. The pressure broadening parameters are determined with better than 1% accuracy, while the temperature dependence exponents are obtained within 1.5-3% accuracy for the normal species transitions

  17. Compressive sensing for high resolution profiles with enhanced Doppler performance

    NARCIS (Netherlands)

    Anitori, L.; Hoogeboom, P.; Chevalier, F. Le; Otten, M.P.G.

    2012-01-01

    In this paper we demonstrate how Compressive Sensing (CS) can be used in pulse-Doppler radars to improve the Doppler performance while preserving range resolution. We investigate here two types of stepped frequency waveforms, the coherent frequency bursts and successive frequency ramps, which can be

  18. Study on Zero-Doppler Centroid Control for GEO SAR Ground Observation

    Directory of Open Access Journals (Sweden)

    Yicheng Jiang

    2014-01-01

    Full Text Available In geosynchronous Earth orbit SAR (GEO SAR, Doppler centroid compensation is a key step for imaging process, which could be performed by the attitude steering of a satellite platform. However, this zero-Doppler centroid control method does not work well when the look angle of radar is out of an expected range. This paper primarily analyzes the Doppler properties of GEO SAR in the Earth rectangular coordinate. Then, according to the actual conditions of the GEO SAR ground observation, the effective range is presented by the minimum and maximum possible look angles which are directly related to the orbital parameters. Based on the vector analysis, a new approach for zero-Doppler centroid control in GEO SAR, performing the attitude steering by a combination of pitch and roll rotation, is put forward. This approach, considering the Earth’s rotation and elliptical orbit effects, can accurately reduce the residual Doppler centroid. All the simulation results verify the correctness of the range of look angle and the proposed steering method.

  19. Pion broadening and low-mass dilepton production

    International Nuclear Information System (INIS)

    Schulze, H.-J.; Blaschke, D.

    2002-01-01

    Mass and transverse momentum spectra of dileptons produced in Pb + Au (158 GeV/u) collisions within a pion annihilation model are determined. A fit to the data requires simultaneous mass reduction and broadening of the in-medium rho propagator. The introduction of a finite pion width, as required within self-consistent approaches to the interacting pion gas, further improves the agreement with the data

  20. Precise Doppler shift compensation in the hipposiderid bat, Hipposideros armiger.

    Science.gov (United States)

    Schoeppler, Diana; Schnitzler, Hans-Ulrich; Denzinger, Annette

    2018-03-15

    Bats of the Rhinolophidae and Hipposideridae families, and Pteronotus parnellii, compensate for Doppler shifts generated by their own flight movement. They adjust their call frequency such that the frequency of echoes coming from ahead fall in a specialized frequency range of the hearing system, the auditory fovea, to evaluate amplitude and frequency modulations in echoes from fluttering prey. Some studies in hipposiderids have suggested a less sophisticated or incomplete Doppler shift compensation. To investigate the precision of Doppler shift compensation in Hipposideros armiger, we recorded the echolocation and flight behaviour of bats flying to a grid, reconstructed the flight path, measured the flight speed, calculated the echo frequency, and compared it with the resting frequency prior to each flight. Within each flight, the average echo frequency was kept constant with a standard deviation of 110 Hz, independent of the flight speed. The resting and reference frequency were coupled with an offset of 80 Hz; however, they varied slightly from flight to flight. The precision of Doppler shift compensation and the offset were similar to that seen in Rhinolophidae and P. parnellii. The described frequency variations may explain why it has been assumed that Doppler shift compensation in hipposiderids is incomplete.

  1. Renal Power Doppler Ultrasonographic Evaluation of Children With Acute Pyelonephritis

    Directory of Open Access Journals (Sweden)

    Ali Pahlusi

    2011-10-01

    Full Text Available Urinary tract infections are common in children. The available gold standard method for diagnosis, Tc-99m dimercaptosuccinic acid scan is expensive and exposes patients to considerable amount of radiation. This study was performed to compare and assess the efficacy of Power Doppler Ultrasound versus Tc-99m DMSA scan for diagnosis of acute pyelonephritis. A quasi experimental study was conducted on 34 children with mean age of 2.82.7 years who were hospitalized with their first episode of febrile urinary tract infection. All children were evaluated in the first 3 days of admission by Doppler Ultrasound and Tc-99m DMSA scan. Patients with congenital structural anomalies were excluded. Each kidney was divided into three zones. The comparison between efficacy of Doppler Ultrasound and DMSA scan was carried out based on number of patients and on classified renal units. Based on the number of patients enrolled; the sensitivity, specificity, positive and negative predictive values and accuracy of Doppler Ultrasound were 89%, 53%, 70%, 80% and 74%, respectively but based on the renal units, it was 66%, 81%, 46%, 91% and 79% , respectively. Although Doppler Ultrasound has the potential for identifying acute pyelonephritis in children, but it is still soon to replace DMSA scan.

  2. The effect of broadened linewidth induced by dispersion on the performance of resonant optical gyroscope

    Science.gov (United States)

    Zhang, Hao; Li, Wenxiu; Han, Peng; Chang, Xiaoyang; Liu, Jiaming; Lin, Jian; Xue, Xia; Zhu, Fang; Yang, Yang; Liu, Xiaojing; Zhang, Xiaofu; Huang, Anping; Xiao, Zhisong; Fang, Jiancheng

    2018-01-01

    Anomalous dispersion enhancement physical mechanism for Sagnac effect is described by special relativity derivation, and three kinds of definitions of minimum detectable angular rate of resonance optical gyroscope (ROG) are compared and the relations among them are investigated. The effect of linewidth broadening induced by anomalous dispersion on the sensitivity of ROG is discussed in this paper. Material dispersion-broadened resonance linewidth deteriorates the performance of a passive ROG and dispersion enhancement effect, while the sensitivity of a structural dispersion ROG is enhanced by two orders of magnitude even considering the dispersion-broadened resonance linewidth.

  3. Endosonographic and color doppler flow imaging alterations observed within irradiated rectal cancer

    International Nuclear Information System (INIS)

    Alexander, Archie A.; Palazzo, Juan P.; Ahmad, Neelofur R.; Liu, J.-B.; Forsberg, Flemming; Marks, John

    1996-01-01

    Purpose: To correlate the endosonographic and color Doppler flow imaging alterations observed in irradiated rectal cancers with the pathologic features of radiation response, and to evaluate the potential impact of altered blood flow on the integrity of the surgical anastamosis. Methods and Materials: Endosonography with color and pulsed wave Doppler was performed on 20 rectal cancer masses before and after high dose preoperative radiation (XRT). Pre- and post-XRT observations included comparing alterations in tumor size, sonographic echotexture, color Doppler flow, and pulsatility indices. Comparisons were made with pathologic findings in the irradiated specimens and with the incidence of anastomotic failure. Results: Compared to pre-XRT observations, irradiated rectal cancers decreased in size and became either mixed in echogenicity with less apparent color Doppler flow (16 of 20) or unchanged in color Doppler flow and echotexture (4 of 20). Those with less flow (16 of 20) were imaged later (mean = 90.2 ± 12.1 days) than those without change in color Doppler flow (mean = 21.7 ± 2.7 days). Pathologically, the group of four without change in color Doppler signal had features of acute inflammation which were not observed in 16 of 20 imaged later. Based on pulsatility index measurements, both high and low resistance vessels were detected and confirmed by immunohistochemical staining, and features of postradiation obliterative vasculitis were observed. Only one primary anastomosis in 14 patients with decreased flow failed. Conclusions: The sonographic and color Doppler flow imaging alterations observed within irradiated rectal cancer correlated with changes of postradiation obliterative vasculitis. The apparent diminished local blood flow within high and low resistance vessels post-XRT did not result in an increased incidence of anastomotic failures

  4. Tissue Doppler echocardiography – A case of right tool, wrong use

    Directory of Open Access Journals (Sweden)

    Thomas George

    2004-08-01

    Full Text Available Abstract Background The developments in echocardiography or ultrasound cardiography (UCG have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE is one such example? Presentation of the hypothesis TDE has been touted as advancement in the field of echocardiography. The striking play of colors, impressive waveforms and the seemingly accurate velocity values could be deceptive. TDE is a clear case of inappropriate use of technology. Testing the hypothesis To understand this, a comparison between flow Doppler and tissue Doppler is made. To make clinically meaningful velocity measurements with Doppler, we need prior knowledge of the line of motion. This is possible in blood flow but impossible in the complex myocardial motion. The qualitative comparison makes it evident that Doppler is best suited for flow studies. Implications of the hypothesis As of now TDE is going backwards using an indirect method when direct methods are better. The work on TDE at present is only debatable 'research and publication' material and do not translate into tangible clinical benefits. There are several advances like curved M-mode, strain rate imaging and tissue tracking in TDE. However these have been disappointing. This is due to the basic flaw in the application of the principles of Doppler. Doppler is best suited for flow studies and applying it to tissue motion is illogical. All data obtained by TDE is scientifically incorrect. This makes all the published papers on the subject flawed. Making diagnostic decisions based on this faulty application of technology would be unacceptable to the scientific cardiologist.

  5. Phylloedes tumor of breast: findings at mammography, sonography and color Doppler imaging

    International Nuclear Information System (INIS)

    Park, Kun Choon; Ahn, Sei Hyun; Kim, Young Hwan; Choi, Hye Yong; Baek, Seung Yon; Yoon, Jeong Hyun

    1994-01-01

    The phylloides tumor of the breast is rare. the purposes of this study were to find the characteristic findings at mammography, sonography, and color Doppler imaging and to evaluate the usefulness of color Doppler study as an additional modality in the diagnosis of phylloides tumor and differentiation between benign and malignant varieties. Eight cases, who were pathologically proven as pylloides tumors, were retrospectively studied. The findings at histologic examination suggested benign in five, malignantin two, and borderline in one. We analyzed the mammograms of all eight patients and sonogram and color Doppler images of four patients. Phylloides tumors were seen as dense masses with lobulated margins in mammograms. On sonography, they showed relatively well-defined masses with in homogenous internal echo pattern and central echogenic areas. They were characterized by the presence of arterial and venous flows in the center and periphery of the lesion on color Doppler imaging and spectral analysis. We conclude that mammographic, sonographic and even color Doppler findings are not predictive of benign or malignant nature of the phylloides tumor. However, mammography and sonography with color Doppler interrogation are helpful in the diagnosis of phylloides tumor

  6. Broadening of ICRH produced fast ion profiles due to orbit effects

    International Nuclear Information System (INIS)

    Eriksson, L.-G.; Porcelli, F.

    1991-01-01

    In the JET tokamak, minority ions accelerated by ICRH reach energies in the MeV range. Near the plasma magnetic axis, the standard trapped particle ''banana'' orbit is distorted into a ''potato'' or ''fat banana'' orbit. The zero banana width approximation which is used in most Fokker-Planck calculations of velocity distributions of resonating ions is often not valid in JET. The inclusion of finite banana width effects will, in general, lead to a lowering of the averaged tail energy and a broadening of pressure profiles, power transfer profiles etc. A model for calculating orbit broadened profiles is presented. (Author)

  7. Application of positron annihilation techniques for semiconductor studies

    International Nuclear Information System (INIS)

    Karwasz, G.P.; Zecca, A.; Brusa, R.S.; Pliszka, D.

    2004-01-01

    Positron annihilation techniques, being non-destructive, allowing depth profiling down to a few micrometers and detecting open-volume defects (vacancies, dislocations etc.) at single ppm concentrations constitute a valuable and complementary method, compared to other solid-state-physics studies. We give examples of investigation in the field of semiconductors with different techniques, both with and without use of positron low-energy beams. The Doppler broadening of the 511 keV annihilation line method and the slow positron beam were used to study helium-implanted silicon and the surface reduction processes in semiconducting glasses. The positron lifetime technique and coincidence spectra of the Doppler broadening were used for systematic studies of metals and semiconductors. Doppler-coincidence method was then used to identify the kinetics of oxygen precipitates in Czochralski-grown silicon

  8. TORSION TESTIS : ROLE OF COLOR DOPPLER : A STUDY OF 50 CASES

    Directory of Open Access Journals (Sweden)

    Anand

    2015-09-01

    Full Text Available BACKGROUND: T orsion testis is one of the catast r ophic conditions in children and young a d u lts. Traditionally the diagnosis was made clinical presentation and suspicion. Critical decision making is essential to save the testis . OBJECTIVE: To study the usefu lness and efficacy of Doppler ultrasound in correctly diagnosing acute scrotal conditions in children and young adults to save the testis and to avoid negative explorations. METHODS: Over a period of two years 50 patients with acute scrotum were admitted i n general surgery department who underwent Doppler ultrasound scrotum and its efficacy in correctly diagnosing the pathology was analysed. RESULTS: 50 patients with age group <25 years were included in study. Scrotal pain was the most frequent presenting s ymptom of acute scrotum (98% followed by Swelling of the hemiscrolum on the involved side present in 86% of the patients. Doppler ultrasound showed torsion of testis in 18 patients. On Scrotal exploration, torsion of spermatic cord was confirmed in 16 pat ients, one patient had torsion of appendix of testis and the other had Epididymo - orchitis. Thus the sensitivity and specificity of Doppler ultrasonography for testicular torsion was 86.9% and 92.6% respectively. 2 patients with equivocal Doppler findings, but strong clinical suspicion of testicular torsion were explored, and testis was found to be torsed in both two patients. Doppler ultrasonography showed Epididymo - orchitis in 22 patients, torsion of testicular appendage in 2 patients, Idiopathic scrotal edema in one, and in 5 pts no significant pathology found. All twenty patients of epididymo - orchitis, two patients of torsion of testicular appendage, and one patient of idiopathic scrotal edema were managed conservatively. At three weeks follow up, all th e patients were free of symptoms. The sensitivity and specificity of Doppler ultrasonography for epididymo - orchitis was 95% and 100% respectively. CONCLUSIONS: color

  9. High-frequency Doppler ultrasound transducer for the peripheral circulatory system

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Youngmin; Yang, Jeongwon; Kang, Uk; Kim, Guanghoon [Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2011-12-15

    A Doppler ultrasound transducer was designed and implemented to measure the blood flow velocity in tiny vessels near the skin of hands or feet. The geometric parameters of the transducer for defining the observation volume were derived and implemented with an acoustic window made of polystyrene. The observation volume designed in this study was located 6.5 mm from the transducer, which was comparable to the value predicted geometrically. The two-way insertion loss of the transducer was -11.3 dB on ultrasound frequency of 20 MHz, and the 3-dB bandwidth was approximately 2 MHz. In addition, the Doppler shift in the frequency measured by using a Doppler device composed of the transducer and a Doppler signal processing unit was proportional to the flow velocity generated by a homemade flowing system. Finally, we concluded that the transducer could be applied to measure the blood flow velocity in hands or feet.

  10. High-frequency Doppler ultrasound transducer for the peripheral circulatory system

    International Nuclear Information System (INIS)

    Bae, Youngmin; Yang, Jeongwon; Kang, Uk; Kim, Guanghoon

    2011-01-01

    A Doppler ultrasound transducer was designed and implemented to measure the blood flow velocity in tiny vessels near the skin of hands or feet. The geometric parameters of the transducer for defining the observation volume were derived and implemented with an acoustic window made of polystyrene. The observation volume designed in this study was located 6.5 mm from the transducer, which was comparable to the value predicted geometrically. The two-way insertion loss of the transducer was -11.3 dB on ultrasound frequency of 20 MHz, and the 3-dB bandwidth was approximately 2 MHz. In addition, the Doppler shift in the frequency measured by using a Doppler device composed of the transducer and a Doppler signal processing unit was proportional to the flow velocity generated by a homemade flowing system. Finally, we concluded that the transducer could be applied to measure the blood flow velocity in hands or feet.

  11. Curriculum of broaden education and theory of teaching activity in school Physical Education

    Directory of Open Access Journals (Sweden)

    Sirléia Silvano

    2016-05-01

    Full Text Available This paper focuses on the conception of curriculum with broaden character in Physical Education and Davidov and Leontiev’s learning theory as possibility of focusing on human education in the omnilateral perspective. We endorse the necessity that the curriculum dynamics – dealing with knowledge, school systematization and standardization of school practices – becomes effective in a curriculum of broaden character. We consider that dealing with knowledge involves the necessity to create conditions that promote the transmission and assimilation of school knowledge. We refer therefore to a scientific direction of the teaching process, in other words, that the teacher leads the student to enter into study activity; from abstract knowledge rising to concrete theoretical knowledge, which is brought about by curriculum organization from a broaden conception.

  12. Proposed protocols for peripheral and renal Doppler

    International Nuclear Information System (INIS)

    Fonseca Portuguez, Adriana

    2009-01-01

    A literature review was performed in order to prepare a summary of the important concepts of Doppler and applications in peripheral vascular evaluation and renal. The normal characteristics are summarized and explained in each vascular system and diagnostic criteria of the disorders frequently encountered in practice. Requested more studies have been identified and proposed protocols and report sheets have been developed to standardize the methodology of realization of several Doppler studies. The variability between operators has been treated to reduce as much as possible and follow-up studies have provided in patients who need. (author) [es

  13. A simplified study of trans-mitral Doppler patterns

    Directory of Open Access Journals (Sweden)

    Thomas George

    2008-11-01

    Full Text Available Abstract Background Trans-mitral Doppler produces complex patterns with a great deal of variability. There are several confusing numerical measures and indices to study these patterns. However trans-mitral Doppler produces readymade data visualization by pattern generation which could be interpreted by pattern analysis. By following a systematic approach we could create an order and use this tool to study cardiac function. Presentation of the hypothesis In this new approach we eliminate the variables and apply pattern recognition as the main criterion of study. Proper terminologies are also devised to avoid confusion. In this way we can get some meaningful information. Testing the hypothesis Trans-mitral Doppler should be seen as patterns rather than the amplitude. The hypothesis can be proven by logical deduction, extrapolation and elimination of variables. Trans-mitral flow is also analyzed vis-à-vis the Starling's Law applied to the left atrium. Implications of the hypothesis Trans-mitral Doppler patterns are not just useful for evaluating diastolic function. They are also useful to evaluate systolic function. By following this schema we could get useful diagnostic information and therapeutic options using simple pattern recognition with minimal measurements. This simplified but practical approach will be useful in day to day clinical practice and help in understanding cardiac function better. This will also standardize research and improve communication.

  14. New positron annihilation spectroscopy techniques for thick materials

    International Nuclear Information System (INIS)

    Selim, F.A.; Wells, D.P.; Harmon, J.F.; Kwofie, J.; Erikson, G.; Roney, T.

    2003-01-01

    The Idaho Accelerator Center (IAC) has developed new techniques for positron annihilation spectroscopy (PAS) by using highly penetrating γ-rays to create positrons inside the material via pair production. Two sources of γ-rays have been employed. Bremsstrahlung beams from small-electron linacs (6 MeV) were used to generate positrons inside the material to perform Doppler-broadening spectroscopy. A 2 MeV proton beam was used to obtain coincident γ-rays from 27 Al target and enable lifetime and Doppler-broadening spectroscopy. This technique successfully measured stress/strain in thick samples, and showed promise to extend PAS into a variety of applications

  15. Positron bound states on hydride ions in thermochemically reduced MgO single crystals

    International Nuclear Information System (INIS)

    Monge, M.A.; Pareja, R.; Gonzalez, R.; Chen, Y.

    1996-01-01

    Positron-lifetime and Doppler-broadening techniques were used to unambiguously identify positronium hydrides in thermochemically reduced MgO crystals at low temperatures. Positrons trapped at H - ions, forming PsH, yield a lifetime of (640±40) ps, independent of temperature. Complementary evidence for this identification was provided by Doppler-broadening experiments, in which positrons were trapped at H 2- sites at low temperatures. The H 2- ions were formed via H - +e - →H 2- by the capturing of an electron released from Fe + impurity under blue-light stimulation. copyright 1996 The American Physical Society

  16. Radar Micro-Doppler Feature Extraction Using the Singular Value Decomposition

    NARCIS (Netherlands)

    Wit, J.J.M. de; Harmanny, R.I.A.; Molchanov, P.

    2014-01-01

    Abstract—The micro-Doppler spectrogram depends on parts of a target moving and rotating in addition to the main body motion (e.g., spinning rotor blades) and is thus characteristic for the type of target. In this study, the micro-Doppler spectrogram is exploited to distinguish between birds and

  17. Monte Carlo simulation and gaussian broaden techniques for full energy peak of characteristic X-ray in EDXRF

    International Nuclear Information System (INIS)

    Li Zhe; Liu Min; Shi Rui; Wu Xuemei; Tuo Xianguo

    2012-01-01

    Background: Non-standard analysis (NSA) technique is one of the most important development directions of energy dispersive X-ray fluorescence (EDXRF). Purpose: This NSA technique is mainly based on Monte Carlo (MC) simulation and full energy peak broadening, which were studied preliminarily in this paper. Methods: A kind of MC model was established for Si-PIN based EDXRF setup, and the flux spectra were obtained for iron ore sample. Finally, the flux spectra were broadened by Gaussian broaden parameters calculated by a new method proposed in this paper, and the broadened spectra were compared with measured energy spectra. Results: MC method can be used to simulate EDXRF measurement, and can correct the matrix effects among elements automatically. Peak intensities can be obtained accurately by using the proposed Gaussian broaden technique. Conclusions: This study provided a key technique for EDXRF to achieve advanced NSA technology. (authors)

  18. Acoustic doppler methods for remote measurements of ocean flows - a review

    Digital Repository Service at National Institute of Oceanography (India)

    Joseph, A.

    The evolution of acoustic doppler methods for remote measurements of ocean flows has been briefly reviewed in historical perspective. Both Eulerian and profiling methods have been discussed. Although the first acoustic Doppler current meter has been...

  19. Developments in target micro-Doppler signatures analysis: radar imaging, ultrasound and through-the-wall radar

    OpenAIRE

    Clemente, C.; Balleri, A.; Woodbridge, K.; Soraghan, J. J.

    2013-01-01

    Target motions, other than the main bulk translation of the target, induce Doppler modulations around the main Doppler shift that form what is commonly called a target micro-Doppler signature. Radar micro-Doppler signatures are generally both target and action speci c and hence can be used to classify and recognise targets as well as to identify possible threats. In recent years, research into the use of micro-Doppler signatures for target classi cation to address many defence and security ch...

  20. Numerical stud of glare spot phase Doppler anemometry

    OpenAIRE

    Hespel , Camille; Ren , Kuan Fang; Gréhan , Gérard; Onofri , Fabrice

    2008-01-01

    International audience; The phase Doppler anemometry has (PDA) been developed to measure simultaneously the velocity and the size of droplets. When the concentration of particles is high, tightly focused beams must be used, as in the dual burst PDA. The latter permits an access to the refractive index of the particle, but the effect of wave front curvature of the incident beams becomes evident. In this paper, we introduce a glare spot phase Doppler anemometry which uses two large beams. The i...

  1. Transcranial Doppler ultrasound and cerebral angiography - alternative or complementary

    International Nuclear Information System (INIS)

    Bockenheimer, S.; Lorey, N.

    1985-01-01

    Transcranial Doppler ultrasound is a noninvasive method of recording the flow velocity of larger intracranial vessels. The impact on diagnosis of cerebravascular occlusive disease is not yet evaluated. We present 15 patients, age range 39-73 years, who suffered from completed stroke. The findings of transcranial Doppler ultrasound and of cerebral angiography are presented. The value of both methods in treatment strategy is discussed. (orig.) [de

  2. Predictable progressive Doppler deterioration in IUGR: does it really exist?

    LENUS (Irish Health Repository)

    Unterscheider, Julia

    2013-12-01

    An objective of the Prospective Observational Trial to Optimize Pediatric Health in IUGR (PORTO) study was to evaluate multivessel Doppler changes in a large cohort of intrauterine growth restriction (IUGR) fetuses to establish whether a predictable progressive sequence of Doppler deterioration exists and to correlate these Doppler findings with respective perinatal outcomes.

  3. The use ofDoppler velocitnetry ofthe utnbilical artery before 24 ...

    African Journals Online (AJOL)

    growth retardation with umbilical artery Doppler ultrasonography. BM] 1989; 298: 631-635. 12. Schulman H, Winter D, Farmakides G, er al. Pregnancy surveil- lance with Doppler velocimerry of the uterine and umbilical arter- ies. Am] Obstet Gyneco11989; 160: 192-196. 13. Hanrerry KP, Primrose MH, Neilson JP, Whittle MJ.

  4. The Frequency Evolution of Interstellar Pulse Broadening from Radio Pulsars

    Science.gov (United States)

    Löhmer, O.; Mitra, D.; Gupta, Y.; Kramer, M.; Ahuja, A.

    2004-10-01

    Using radio pulsars as probes of the interstellar medium (ISM) we study the frequency evolution of interstellar scattering. The frequency dependence of scatter broadening times, τsc, for most of the pulsars with low and intermediate dispersion measures (DM ≲ 400 pc cm-3) is consistent with the Kolmogorov spectrum of electron density fluctuations in a turbulent medium. In contrast, the measured τsc's for highly dispersed pulsars in the central region of the Galaxy are larger than expected and show a spectrum which is flatter than the Kolmogorov law. We analyse the first measurements of spectral indices of scatter broadening over the full known DM range and discuss possible explanations for the anomalous scattering behaviour along peculiar lines of sight (LOS).

  5. Broadening the Study of Participation in the Life Sciences: How Critical Theoretical and Mixed-Methodological Approaches Can Enhance Efforts to Broaden Participation

    Science.gov (United States)

    Metcalf, Heather

    2016-01-01

    This research methods Essay details the usefulness of critical theoretical frameworks and critical mixed-methodological approaches for life sciences education research on broadening participation in the life sciences. First, I draw on multidisciplinary research to discuss critical theory and methodologies. Then, I demonstrate the benefits of these…

  6. [Doppler echocardiography of tricuspid insufficiency. Methods of quantification].

    Science.gov (United States)

    Loubeyre, C; Tribouilloy, C; Adam, M C; Mirode, A; Trojette, F; Lesbre, J P

    1994-01-01

    Evaluation of tricuspid incompetence has benefitted considerably from the development of Doppler ultrasound. In addition to direct analysis of the valves, which provides information about the mechanism involved, this method is able to provide an accurate evaluation, mainly through use of the Doppler mode. In addition to new criteria being evaluated (mainly the convergence zone of the regurgitant jet), some indices are recognised as good quantitative parameters: extension of the regurgitant jet into the right atrium, anterograde tricuspid flow, laminar nature of the regurgitant flow, analysis of the flow in the supra-hepatic veins, this is only semi-quantitative, since the calculation of the regurgitation fraction from the pulsed Doppler does not seem to be reliable; This accurate semi-quantitative evaluation is made possible by careful and consistent use of all the criteria available. The authors set out to discuss the value of the various evaluation criteria mentioned in the literature and try to define a practical approach.

  7. Contrast-enhanced power Doppler US in the characterization of renal masses

    International Nuclear Information System (INIS)

    Ascenti, G.; Zimbaro, G.; Mazziotti, S.; Visalli, C.; Racchiusa, S.; Vinci, S.; Scribano, E.

    2000-01-01

    Purpose of this work is to report the results of a prospective study investigating the potentials of contrast-enhanced power Doppler in the diagnosis of expansive renal lesions. From 1997 to October 30, 1999, it was studied the case of 59 expansive renal lesions (28 malignant, 31 benign) in 48 patients (mean age 55 years, range 10-79) with power Doppler US before and after the administration of an echo-enhancing agent (Levovist, Schering AG, Berlin Germany). Were found 5 patterns of vascular architecture of the lesions, both before and after contrast agent administration, following the classification by Jinzaki e Coll. Power Doppler US showed vascular structures in 34 patients. The administration of Levovist revealed vessels in 12/25 lesions which had none at baseline studies and in 6 cases vascularity was particularly evident. Color signals were enhanced in all the 34 vascularized lesions, which allowed better definition of vascular patterns. The characterization of vascular patterns with baseline power Doppler US helped improve diagnostic accuracy compared to gray-scale US (58% versus 32%) for hyperechoic lesions, complex cysts and pseudomasses. Independent of contrast agent administration, the integration of gray-scale and power Doppler modes increased diagnostic accuracy even further (76% correct diagnoses). In our series, the US contrast agent did not increase the diagnostic accuracy of power Doppler in the differential diagnosis of hyperechoic renal lesions; conversely, Levovist can be advantageous for the characterization of suspected pseudomasses and complex cysts [it

  8. Micro-Doppler Ambiguity Resolution for Wideband Terahertz Radar Using Intra-Pulse Interference.

    Science.gov (United States)

    Yang, Qi; Qin, Yuliang; Deng, Bin; Wang, Hongqiang; You, Peng

    2017-04-29

    Micro-Doppler, induced by micro-motion of targets, is an important characteristic of target recognition once extracted via parameter estimation methods. However, micro-Doppler is usually too significant to result in ambiguity in the terahertz band because of its relatively high carrier frequency. Thus, a micro-Doppler ambiguity resolution method for wideband terahertz radar using intra-pulse interference is proposed in this paper. The micro-Doppler can be reduced several dozen times its true value to avoid ambiguity through intra-pulse interference processing. The effectiveness of this method is proved by experiments based on a 0.22 THz wideband radar system, and its high estimation precision and excellent noise immunity are verified by Monte Carlo simulation.

  9. A Comprehensive Radial Velocity Error Budget for Next Generation Doppler Spectrometers

    Science.gov (United States)

    Halverson, Samuel; Ryan, Terrien; Mahadevan, Suvrath; Roy, Arpita; Bender, Chad; Stefansson, Guomundur Kari; Monson, Andrew; Levi, Eric; Hearty, Fred; Blake, Cullen; hide

    2016-01-01

    We describe a detailed radial velocity error budget for the NASA-NSF Extreme Precision Doppler Spectrometer instrument concept NEID (NN-explore Exoplanet Investigations with Doppler spectroscopy). Such an instrument performance budget is a necessity for both identifying the variety of noise sources currently limiting Doppler measurements, and estimating the achievable performance of next generation exoplanet hunting Doppler spectrometers. For these instruments, no single source of instrumental error is expected to set the overall measurement floor. Rather, the overall instrumental measurement precision is set by the contribution of many individual error sources. We use a combination of numerical simulations, educated estimates based on published materials, extrapolations of physical models, results from laboratory measurements of spectroscopic subsystems, and informed upper limits for a variety of error sources to identify likely sources of systematic error and construct our global instrument performance error budget. While natively focused on the performance of the NEID instrument, this modular performance budget is immediately adaptable to a number of current and future instruments. Such an approach is an important step in charting a path towards improving Doppler measurement precisions to the levels necessary for discovering Earth-like planets.

  10. Investigation of the chemical vicinity of defects in Mg and AZ31 with positron coincident Doppler boarding spectroscopy

    International Nuclear Information System (INIS)

    Stadlbauer, Martin

    2008-01-01

    Within the scope of the present work, two main goals have been achieved: Firstly, the coincident Doppler broadening spectrometer (CDBS) at the high intense positron source NEPOMUC has been elaborately improved in order to increase the spatial resolution for defect mapping measurements and to investigate samples with shallow positron trapping sites which are present e. g. in magnesium. Secondly, as an application, the chemical vicinity of defects in the industrially used magnesium based alloy AZ31 has been examined by means of the detailed investigation of ion-irradiated specimen with positron annihilation spectroscopy. Detailed simulations with the finite-element simulation tool COMSOL were used to optimize the focal diameter of the positron beam at the sample position in order to increase the spatial resolution. With a value of 0.3 mm, sub-mm resolution has now been reached. The CDBS has been furthermore equipped with a sample cooling unit in order to reach liquid nitrogen temperature, maintaining the feature of scanning the sample for defect mapping. Defects and their chemical surrounding in ion irradiated magnesium and the magnesium based alloy AZ31 were then investigated on an atomic scale with the CDBS. In the respective spectra the chemical information and the defect contribution have been thoroughly separated. For this purpose, samples of annealed Mg were irradiated with Mg-ions in order to create exclusively defects. In addition Al- and Zn-ion irradiations on Mg-samples were performed in order to create samples with both defects and impurity atoms. The ion irradiated area on the samples was investigated with laterally and depth resolved positron Doppler broadening spectroscopy (DBS) and compared with SRIM-simulations of the vacancy distribution. The investigation of the chemical vicinity of crystal defects in AZ31 was performed with CDBS on Mg-ion irradiated AZ31 with Mg-ion irradiated Mg. The outer tail of the energy distribution in the annihilation

  11. Investigation of the chemical vicinity of defects in Mg and AZ31 with positron coincident Doppler boarding spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Stadlbauer, Martin

    2008-03-10

    Within the scope of the present work, two main goals have been achieved: Firstly, the coincident Doppler broadening spectrometer (CDBS) at the high intense positron source NEPOMUC has been elaborately improved in order to increase the spatial resolution for defect mapping measurements and to investigate samples with shallow positron trapping sites which are present e. g. in magnesium. Secondly, as an application, the chemical vicinity of defects in the industrially used magnesium based alloy AZ31 has been examined by means of the detailed investigation of ion-irradiated specimen with positron annihilation spectroscopy. Detailed simulations with the finite-element simulation tool COMSOL were used to optimize the focal diameter of the positron beam at the sample position in order to increase the spatial resolution. With a value of 0.3 mm, sub-mm resolution has now been reached. The CDBS has been furthermore equipped with a sample cooling unit in order to reach liquid nitrogen temperature, maintaining the feature of scanning the sample for defect mapping. Defects and their chemical surrounding in ion irradiated magnesium and the magnesium based alloy AZ31 were then investigated on an atomic scale with the CDBS. In the respective spectra the chemical information and the defect contribution have been thoroughly separated. For this purpose, samples of annealed Mg were irradiated with Mg-ions in order to create exclusively defects. In addition Al- and Zn-ion irradiations on Mg-samples were performed in order to create samples with both defects and impurity atoms. The ion irradiated area on the samples was investigated with laterally and depth resolved positron Doppler broadening spectroscopy (DBS) and compared with SRIM-simulations of the vacancy distribution. The investigation of the chemical vicinity of crystal defects in AZ31 was performed with CDBS on Mg-ion irradiated AZ31 with Mg-ion irradiated Mg. The outer tail of the energy distribution in the annihilation

  12. Carotid Doppler ultrasound findings in patients with left ventricular assist devices.

    Science.gov (United States)

    Cervini, Patrick; Park, Soon J; Shah, Dipesh K; Penev, Irina E; Lewis, Bradley D

    2010-12-01

    Left ventricular assist devices (LVADs) have been used to treat advanced heart failure refractory to medical management, as bridge therapy to myocardial recovery, as bridge therapy to cardiac transplantation, or as destination therapy for patients with unfavorable transplant candidacy. Neurologic complications are some of the most common and devastating complications in these patients. Preoperative carotid ultrasound is, therefore, a standard evaluation in patients at risk for cerebrovascular disease. Postoperative carotid artery Doppler sonography is performed in those patients with neurologic symptoms. It is likely, therefore, that sonographers, radiologists, and other physicians working in a center where LVADs are implanted will likely encounter a carotid artery Doppler study in this patient group. To our knowledge, the carotid Doppler findings in these patients have never been published. We review the Doppler ultrasound findings in 6 patients after LVAD insertion.

  13. Stochastic theory of relaxation and collisional broadening of spectral line shapes

    International Nuclear Information System (INIS)

    Faid, K.

    1986-01-01

    A complete stochastic theory of relaxation is developed in terms of a homogeneous equation for the averaged density matrix of a system immersed in a thermal bath. This theory is then used as the basis of a new stochastic approach to the phenomenon of collisional broadening of spectral line shapes. Single-photon and multiphoton processes are studied. The features of a line shape are linked by simple expressions to the statistical properties of a stochastic hermitian Hamiltonian. The ordinary line shape predicted by Kubo's approach is generalized. The present approach predicts broadening as well as asymmetry and shift. A representation of line shapes in multiphoton processes by diagrams is also developed

  14. Ultrasonic intrusion sensor using the Doppler effect; Choonpa Doppler hoshiki shinnyu sensor

    Energy Technology Data Exchange (ETDEWEB)

    Kani, H; Iwasaki, N; Goto, M [Nippon Soken, Inc., Tokyo (Japan); Tsuzuki, T; Nakamura, T [Denso Corp., Aichi (Japan)

    1997-10-01

    For vehicle anti-theft alarm systems which cope with vehicle and car component theft, EU initiated vehicle security regulations from Jan 1997. Also, the insurance industry has instituted the insurance certification of vehicle anti-theft alarm systems. We have developed an ultrasonic intrusion sensor using the doppler effect for vehicle anti-theft alarm systems specifically for these EU regulations and insurance certification. 2 refs., 7 figs., 1 tab.

  15. Imaging doppler lidar for wind turbine wake profiling

    Science.gov (United States)

    Bossert, David J.

    2015-11-19

    An imaging Doppler lidar (IDL) enables the measurement of the velocity distribution of a large volume, in parallel, and at high spatial resolution in the wake of a wind turbine. Because the IDL is non-scanning, it can be orders of magnitude faster than conventional coherent lidar approaches. Scattering can be obtained from naturally occurring aerosol particles. Furthermore, the wind velocity can be measured directly from Doppler shifts of the laser light, so the measurement can be accomplished at large standoff and at wide fields-of-view.

  16. Radar micro-Doppler of wind turbines : Simulation and analysis using rotating linear wire structures

    NARCIS (Netherlands)

    Krasnov, O.A.; Yarovoy, A.

    2015-01-01

    A simple electromagnetic model of wind-turbine's main structural elements as the linear wired structures is developed to simulate the temporal patterns of observed radar return Doppler spectra (micro-Doppler). Using the model, the micro-Doppler for different combinations of the turbines rotation

  17. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Min, E-mail: limin22000@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Jiang, Xiang-sen, E-mail: jiangxiangsen123@126.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Li, E-mail: leely1976@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Peng, Zhao-hui, E-mail: zhaohuipeng_R@163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Mu, Nan-nan, E-mail: munannan22000@sohu.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China)

    2012-09-15

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality.

  18. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    International Nuclear Information System (INIS)

    Sun, Gang; Li, Min; Jiang, Xiang-sen; Li, Li; Peng, Zhao-hui; Mu, Nan-nan

    2012-01-01

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality

  19. Principles of doppler tomography

    International Nuclear Information System (INIS)

    Juhlin, P.

    1992-08-01

    This paper shows how the radon transform can be used to determine vector fields. A scheme to determine the velocity field of a moving fluid by measurements with a continuous doppler signal is suggested. When the flow is confined to a bounded domain, as is the case in most applications, it can be uniquely decomposed into one gradiental and one rotational part. The former vanishes if the fluid is incompressible and source-free, and the latter can be completely reconstructed by the methods proposed in this paper if the domain is simply connected. Special attention is paid to laminar flow in a long cylindrical vessel with circular cross-section. Under such conditions the flow profile becomes parabolic, which makes the vessel recognizable as a typical 'N-shaped' pattern in an image describing the rotation of the velocity field. The vessel yields the same doppler tomographic pattern, no matter how it is sectioned. The ideas presented should be applicable also when studying the flow in blood vessels, even if the flow profile in these is not quite parabolic. The discrepancies only make the 'N-shape' somewhat distorted

  20. Analysis of Doppler effect measurement in FCA cores using JENDL-3.2 library

    International Nuclear Information System (INIS)

    Okajima, Shigeaki

    1996-01-01

    For the evaluation of the calculation accuracy of the 238 U Doppler effect using JENDL-3.2 library, the previously measured Doppler reactivity worths in the FCA were systematically analyzed. In the analysis the Doppler reactivity worth was calculated by a first order perturbation theory. The calculated results were compared with those using JENDL-3.1 library. The JENDL-3.2 calculation in MOX fuel mock-up cores agrees well with the experimental values within the experimental error. In U-235/Pu fuel cores, the JENDL-3.2 calculation gives 12-15% larger Doppler reactivity worths than the JENDL-3.1 calculation. (author)

  1. Color Doppler US of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Bertolotto, Michele (ed.) [Trieste Univ. Ospedale di Cattinara (Italy). Dept. Radiology

    2008-07-01

    This book provides a comprehensive reference and practical guide on the application of US to penile diseases and conditions. After introductory chapters on technical requirements and penile anatomy, subsequent chapters offer a systematic overview of the diverse applications of color Doppler US. The topics covered include erectile dysfunction, Peyronie's disease, priapism, trauma, tumors, the postoperative penis, inflammation, and fibrosis. Each topic is introduced by a clinical overview with the purpose of clarifying the problems and elucidating what the urologist may expect from color Doppler US. Thereafter, performance of the US study is explained and the pathological anatomy reviewed. High-quality images obtained with high-end US equipment are included. Each chapter also contains a section on the diagnostic information provided by other imaging modalities, and in particular MRI. (orig.)

  2. Determination of intestinal viability by Doppler ultrasonography in venous infarction.

    Science.gov (United States)

    Cooperman, M; Martin, E W; Carey, L C

    1980-01-01

    The accuracy of Doppler ultrasound in predicting the viability of ischemic intestine secondary to venous obstruction was assessed. Twenty loops of ischemic intestine were created in dogs by temporarily obstructing venous return from the bowel. Doppler arterial flow signals within the intestine quickly disappeared following venous occlusion. In ten segments, arterial signals promptly returned following release of venous occlusion. Nine of these ten segments were viable at reoperation 24 hours later. In ten segments, no arterial signals could be detected following release of venous occlusion, and only one segment proved to be viable. Doppler ultrasound findings were far more accurate in distinguishing between viable and nonviable intestine thatn were clinical guides to intestinal viability. PMID:7352777

  3. Effectiveness of Pulse Oximetry Versus Doppler for Tourniquet Monitoring.

    Science.gov (United States)

    Wall, Piper L; Buising, Charisse M; Grulke, Lisa; Troester, Alexander; Bianchina, Nicholas; White, Shannon; Freymark, Rosemarie; Hassan, Ali; Hopkins, James W; Renner, Catherine Hackett; Sahr, Sheryl M

    Pulse oximeters are common and include arterial pulse detection as part of their methodology. The authors investigated the possible usefulness of pulse oximeters for monitoring extremity tourniquet arterial occlusion. Tactical Ratcheting Medical Tourniquets were tightened to the least Doppler-determined occluding pressure at mid-thigh or mid-arm locations on one limb at a time on all four limbs of 15 volunteers. A randomized block design was used to determine the placement locations of three pulse oximeter sensors on the relevant digits. The times and pressures of pulsatile signal absences and returns were recorded for 200 seconds, with the tourniquet being tightened only when the Doppler ultrasound and all three pulse oximeters had pulsatile signals present (pulsatile waveform traces for the pulse oximeters). From the first Doppler signal absence to tourniquet release, toe-located pulse oximeters missed Doppler signal presence 41% to 50% of the times (discrete 1-second intervals) and missed 39% to 49% of the pressure points (discrete 1mmHg intervals); fingerlocated pulse oximeters had miss rates of 11% to 15% of the times and 13% to 19% of the pressure points. On toes, the pulse oximeter ranges of sensitivity and specificity for Doppler pulse detection were 71% to 90% and 44% to 51%, and on fingers, the respective ranges were 65% to 77% and 78% to 83%. Use of a pulse oximeter to monitor limb tourniquet effectiveness will result in some instances of an undetected weak arterial pulse being present. If a pulse oximeter waveform is obtained from a location distal to a tourniquet, the tourniquet should be tightened. If a pulsatile waveform is not detected, vigilance should be maintained. 2017.

  4. Low pressure broadening and shift of the 540.06 nm line of neon

    International Nuclear Information System (INIS)

    Bielski, A.; Dokurno, W.; Szudy, J.; Wolnikowski, J.

    1980-01-01

    The collision broadening and shift of the 540.06 nm line of neon emitted from a low pressure glow discharge in pure neon and a neon-helium mixture have been measured. The values of the broadening and shift coefficients were determined and compared with the results of calculations based on the Lindholm-Foley impact theory assuming a Lennard-Jones potential. The results for pure neon demonstrate the inadequacy of the Lennard-Jones potential for the Ne-Ne interaction. (orig.)

  5. Positive emotions and the social broadening effects of Barack Obama.

    Science.gov (United States)

    Ong, Anthony D; Burrow, Anthony L; Fuller-Rowell, Thomas E

    2012-10-01

    Past experiments have demonstrated that the cognitive broadening produced by positive emotions may extend to social contexts. Building on this evidence, we hypothesized that positive emotions triggered by thinking about Barack Obama may broaden and expand people's sense of self to include others. Results from an expressive-writing study demonstrated that African American college students prompted to write about Obama immediately prior to and after the 2008 presidential election used more plural self-references, fewer other-references, and more social references. Mediation analyses revealed that writing about Obama increased positive emotions, which in turn increased the likelihood that people thought in terms of more-inclusive superordinate categories (we and us rather than they and them). Implications of these findings for the role of positive emotions in perspective-taking and intergroup relations are considered.

  6. Doppler reactivity uncertainties and their effect upon a hypothetical LOF accident

    International Nuclear Information System (INIS)

    Malloy, D.J.

    1976-01-01

    The statistical uncertainties and the major methodological errors which contribute to the Doppler feedback uncertainty were reviewed and investigated. Improved estimates for the magnitudes of each type of uncertainty were established. The generally applied reactivity feedback methodology has been extended by explicitly treating the coupling effect which exists between the various feedback components. The improved methodology was specifically applied to the coupling of Doppler and sodium void reactivities. In addition, the description of the temperature dependence of the Doppler feedback has been improved by the use of a two-constant formula on a global and regional basis. Feedback and coupling coefficients are presented as a first comparison of the improved and the currently applied methods. Further, the energy release which results from hypothetical disassembly accidents was simulated with a special response surface in the parametric safety evaluation code PARSEC. The impact of the improved feedback methodology and of Doppler coefficient uncertainties was illustrated by the usual parametric relationship between available work-energy and the Doppler coefficient. The work-energy was calculated with the VENUS-II disassembly code and was represented as a response surface in PARSEC. Additionally, the probability distribution for available work-energy, which results from the statistical uncertainty of the Doppler coefficient, was calculated for the current and the improved feedback methodology. The improved feedback description yielded about a 16 percent higher average value for the work-energy. A substantially larger increase is found on the high-yield end of the spectrum: the probability for work-energy above 500 MJ was increased by about a factor of ten

  7. Wave mixing spectroscopy

    International Nuclear Information System (INIS)

    Smith, R.W.

    1980-08-01

    Several new aspects of nonlinear or wave mixing spectroscopy were investigated utilizing the polarization properties of the nonlinear output field and the dependence of this field upon the occurrence of multiple resonances in the nonlinear susceptibility. First, it is shown theoretically that polarization-sensitive detection may be used to either eliminate or controllably reduce the nonresonant background in coherent anti-Stokes Raman spectroscopy, allowing weaker Raman resonances to be studied. The features of multi-resonant four-wave mixing are examined in the case of an inhomogeneously broadened medium. It is found that the linewidth of the nonlinear output narrows considerably (approaching the homogeneous width) when the quantum mechanical expressions for the doubly- and triply-resonant susceptibilities are averaged over a Doppler or strain broadened profile. Experimental studies of nonlinear processes in Pr +3 :LaF 3 verify this linewidth narrowing, but indicate that this strain broadened system cannot be treated with a single broadening parameter as in the case of Doppler broadening in a gas. Several susceptibilities are measured from which are deduced dipole matrix elements and Raman polarizabilities related to the 3 H 4 , 3 H 6 , and 3 P 0 levels of the praseodymium ions

  8. The role of Doppler ultrasonography in the evaluation of the renal function

    International Nuclear Information System (INIS)

    Krasteva, R.; Kiperova, B.; Andreev, E.; Kostadinova, I.; Petrov, T.; Hadjidekov, V.; Simeonova, A.

    2008-01-01

    The purpose of the study was to evaluate Doppler ultrasonography in the detection of the renal function. Sixty six patients with unilateral kidney changes were enrolled in this prospective study. 16 had hypoplastic kidney, 24 had hypofunctioned kidney and 26 had afunctioned kidney. 15 healthy potential donors were controls. A dynamic renal scintigraphy was performed with 74-111 MBq 99mTc-MAG3. The Color, Pulsed and Power Doppler were performed. The Vp and δVp derived from the spectrum of the segmental arteries were measured during Pulsed Doppler examination. There are not any difference between kidneys of health and hypoplastic kidneys on color and Power Doppler. The hypofunctioning kidneys had reduced blood flow and afunctioning kidneys had markedly reduced blood flow. The Vp of donors (48.8±7.6) and Vp of hypoplastic kidneys (49.9±4.8) were significantly higher compared to Vp of hypofunctioning kidneys (31.6±10.0) and to Vp of afunctioning kidneys (26.6±9.1), (p 14.5 cm/s in 93%, and from hypofunctioning kidney by delta Vp>10.5 cm/s in 87%. The Doppler ultrasonography is very useful in the evaluation of renal function. The changes of the Doppler parameters accurately marked the loss of function which can not be detected by elevation of the creatinine level. (authors)

  9. Doppler derived gradient of ST Jude Mechanical Prosthesis, early postoperative assessment

    International Nuclear Information System (INIS)

    Shaikh, A.H.; Hanif, B.; Adil, A.; Hashimi, S.; Qazi, H.A.; Mujtaba, I.

    2010-01-01

    Objective: To determine the doppler derived mean gradients of St Jude mechanical prosthesis in early postoperative period in patients undergoing valve replacement at a tertiary care cardiac centre. Methods: Medical records of 190 consecutive patients who underwent 233 mitral, aortic or dual (mitral and aortic) valve replacement by St Jude bileaflet mechanical prosthesis at Tabba Heart Institute, between March 2006 to December 2008 were reviewed. Doppler derived mean gradients were assessed predischarge and recorded. Results: There were 98 (51.5%) males and 92 (48.5%) females in the study cohort. The mean age was 40 +- 14 years. Of the total, 101 (53%) had mitral, 46 (24.2%) had aortic and 43 (22.6%) patients had dual valve replacement. Doppler derived mean gradient was assessed across 144 mitral and 89 aortic St Jude mechanical prosthesis. Doppler derived mean gradient for St Jude mitral prosthesis was 3.5 mm Hg and for St Jude aortic prosthesis was 10.2 mm Hg. Conclusions: The study determines baseline gradients across mitral and aortic St Jude mechanical prosthesis in our population. These can be used as reference gradients to assess St Jude prosthetic valve function in patients who did not have early postoperative doppler assessment. (author)

  10. Broadening and Simplifying the First SETI Protocol

    Science.gov (United States)

    Michaud, M. A. G.

    The Declaration of Principles Concerning Activities Following the Detection of Extraterrestrial Intelligence, known informally as the First SETI Protocol, is the primary existing international guidance on this subject. During the fifteen years since the document was issued, several people have suggested revisions or additional protocols. This article proposes a broadened and simplified text that would apply to the detection of alien technology in our solar system as well as to electromagnetic signals from more remote sources.

  11. Quasi-elastic neutron line broadening in nematic liquid crystals

    International Nuclear Information System (INIS)

    Cvikl, B.; Dimic, V.; Dusic, M.; Kristof, E.; Srebotnjak, E.

    1979-01-01

    On the basis of a new random walk torsional oscillations model of the amplitude φ 0 of rigid flat molecules a quasi-elastic neutron line broadening has been calculated and the results compared to the measurements obtained on the sample of cholesteryl propionate. A good agreement was obtained. (author)

  12. Analysis of placenta vascularization in patients with uterine altered artery Doppler flow velocity exams.

    Science.gov (United States)

    Gilio, Daniel Bruno; Miranda Corrêa, Rosana Rosa; Souza de Oliveira Guimarães, Camila; Peres, Luiz Cesar; Marques Salge, Ana Karina; Cavellani, Camila Lourencini; de Paula Antunes Teixeira, Vicente; Costa da Cunha Castro, Eumenia

    2009-08-01

    One of the frequent questions in obstetric practice is to determine placental vascular changes that may account for abnormal Doppler flow velocity alterations in maternal uterine vessels from women and fetuses without pregnancy pathology. A retrospective morphometric study was realized using 27 placentas from patients submitted for Doppler flow velocity exam during pregnancy. The placentas were morphologically examined using hematoxylin-eosin staining. Measurements of villi were made with the use of a video camera coupled to a common light microscope and a computer with automatic image analyzing software. Of the 27 placentas, 13 (48%) were of patients showing unaltered Doppler and 14 (52%) showing altered Doppler. The number of stem villi vessels was significantly larger in the placentas of patients with Doppler exam alterations (P = 0.003). This group also presented greater stem villi vessel thickness, although without significant difference. The number of intermediary and terminal villi vessels was greater in the placentas of patients with altered Doppler exams (P < 0.001), and a greater terminal villi area was observed in these cases (P < 0.001). The morphological proof that uterine artery Doppler flow velocity exam alterations are associated with placental vascular alterations demonstrates the importance of this exam during prenatal care, even in the absence of maternal-fetal alterations.

  13. Modeling and processing of laser Doppler reactive hyperaemia signals

    Science.gov (United States)

    Humeau, Anne; Saumet, Jean-Louis; L'Huiller, Jean-Pierre

    2003-07-01

    Laser Doppler flowmetry is a non-invasive method used in the medical domain to monitor the microvascular blood cell perfusion through tissue. Most commercial laser Doppler flowmeters use an algorithm calculating the first moment of the power spectral density to give the perfusion value. Many clinical applications measure the perfusion after a vascular provocation such as a vascular occlusion. The response obtained is then called reactive hyperaemia. Target pathologies include diabetes, hypertension and peripheral arterial occlusive diseases. In order to have a deeper knowledge on reactive hyperaemia acquired by the laser Doppler technique, the present work first proposes two models (one analytical and one numerical) of the observed phenomenon. Then, a study on the multiple scattering between photons and red blood cells occurring during reactive hyperaemia is carried out. Finally, a signal processing that improves the diagnosis of peripheral arterial occlusive diseases is presented.

  14. Positive mood broadens visual attention to positive stimuli.

    Science.gov (United States)

    Wadlinger, Heather A; Isaacowitz, Derek M

    2006-03-01

    In an attempt to investigate the impact of positive emotions on visual attention within the context of Fredrickson's (1998) broaden-and-build model, eye tracking was used in two studies to measure visual attentional preferences of college students (n=58, n=26) to emotional pictures. Half of each sample experienced induced positive mood immediately before viewing slides of three similarly-valenced images, in varying central-peripheral arrays. Attentional breadth was determined by measuring the percentage viewing time to peripheral images as well as by the number of visual saccades participants made per slide. Consistent with Fredrickson's theory, the first study showed that individuals induced into positive mood fixated more on peripheral stimuli than did control participants; however, this only held true for highly-valenced positive stimuli. Participants under induced positive mood also made more frequent saccades for slides of neutral and positive valence. A second study showed that these effects were not simply due to differences in emotional arousal between stimuli. Selective attentional broadening to positive stimuli may act both to facilitate later building of resources as well as to maintain current positive affective states.

  15. The Role of Positive Emotions in Positive Psychology: The Broaden-and-Build Theory of Positive Emotions.

    Science.gov (United States)

    Fredrickson, Barbara L.

    2001-01-01

    Describes the broaden-and-build theory of positive emotions, situating it within the field of positive psychology. The theory posits that experiences of positive emotions broaden people's momentary thought-action repertoires, which in turn build their enduring personal resources (physical, intellectual, social, and psychological). Reviews…

  16. Positron trap centers in x-ray and γ-ray irradiated SiO2

    International Nuclear Information System (INIS)

    Khatri, R.; Asoka-Kumar, P.; Nielsen, B.; Roellig, L.O.; Lynn, K.G.

    1993-01-01

    Using Doppler broadening annihilation spectroscopy, we investigated the properties of irradiated samples of SiO 2 /Si(100) with 117 nm thick oxide layer, grown in dry O 2 on p- and n-type substrates. These samples were irradiated with γ rays and x rays at doses in the range of 7x10 4 --9x10 6 rad and 50--2000 mJ/cm 2 , respectively. The changes observed in the Doppler broadening line shape parameter after irradiation and its recovery during isochronal annealing were used to obtain an activation energy of 1.48--1.61 eV required for annealing the defects

  17. Analysis of neutron diffraction peak broadening caused by internal stresses in composite materials

    International Nuclear Information System (INIS)

    Todd, R.I.; Borsa, C.; Derby, B.

    1994-01-01

    Neutron diffraction is an essential tool in the study of internal stresses in composite materials. In most work only the peak shifts caused by the related elastic strains are considered, but other valuable information exists in the form of peak shape changes. The conditions under which the pure diffraction profile of the composite (i.e. the profile when all sources of broadening not caused by the residual stresses are removed) represents the probability distribution of the peak shifts corresponding to the strains are examined. It is shown that in these conditions, the pure diffraction profile has no attributes of particle size broadening (and vice versa), thereby providing a test for the validity of results interpreted in this way. The experimental derivation of measured strain distributions in Al 2 O 3 /SiCp composites using neutron diffraction is described. No apparent particle size broadening was detected, demonstrating the validity of the results, which also satisfied other tests for consistency

  18. Explanation of the Inverse Doppler Effect Observed in Nonlinear Transmission Lines

    International Nuclear Information System (INIS)

    Kozyrev, Alexander B.; Weide, Daniel W. van der

    2005-01-01

    The theory of the inverse Doppler effect recently observed in magnetic nonlinear transmission lines is developed. We explain the crucial role of the backward spatial harmonic in the occurrence of an inverse Doppler effect and draw analogies of the magnetic nonlinear transmission line to the backward wave oscillator

  19. Comparing energy loss and pperpendicular -broadening in perturbative QCD with strong coupling N=4 SYM theory

    International Nuclear Information System (INIS)

    Dominguez, Fabio; Marquet, C.; Mueller, A.H.; Wu Bin; Xiao, Bo-Wen

    2008-01-01

    We compare medium induced energy loss and p perpendicular -broadening in perturbative QCD with that of the trailing string picture of SYM theory. We consider finite and infinite extent matter as well as relativistic heavy quarks which correspond to those being produced in the medium or external to it. When expressed in terms of the appropriate saturation momentum, we find identical parametric forms for energy loss in perturbative QCD and SYM theory. We find simple correspondences between p perpendicular -broadening in QCD and in SYM theory although p perpendicular -broadening is radiation dominated in SYM theory and multiple scattering dominated in perturbative QCD

  20. Feasibility of UltraFast Doppler in Post-operative Evaluation of Hepatic Artery in Recipients following Liver Transplantation.

    Science.gov (United States)

    Kim, Se-Young; Kim, Kyoung Won; Choi, Sang Hyun; Kwon, Jae Hyun; Song, Gi-Won; Kwon, Heon-Ju; Yun, Young Ju; Lee, Jeongjin; Lee, Sung-Gyu

    2017-11-01

    To determine the feasibility of using UltraFast Doppler in post-operative evaluation of the hepatic artery (HA) after liver transplantation (LT), we evaluated 283 simultaneous conventional and UltraFast Doppler sessions in 126 recipients over a 2-mo period after LT, using an Aixplorer scanner The Doppler indexes of the HA (peak systolic velocity [PSV], end-diastolic velocity [EDV], resistive index [RI] and systolic acceleration time [SAT]) by retrospective analysis of retrieved waves from UltraFast Doppler clips were compared with those obtained by conventional spectral Doppler. Correlation, performance in diagnosing the pathologic wave, examination time and reproducibility were evaluated. The PSV, EDV, RI and SAT of spectral and UltraFast Doppler measurements exhibited excellent correlation with favorable diagnostic performance. During the bedside examination, the mean time spent for UltraFast clip storing was significantly shorter than that for conventional Doppler US measurements. Both conventional and UltraFast Doppler exhibited good to excellent inter-analysis consistency. In conclusion, compared with conventional spectral Doppler, UltraFast Doppler values correlated excellently and yielded acceptable pathologic wave diagnostic performance with reduced examination time at the bedside and excellent reproducibility. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. Testing the relativistic Doppler boost hypothesis for supermassive black hole binary candidates

    Science.gov (United States)

    Charisi, Maria; Haiman, Zoltán; Schiminovich, David; D'Orazio, Daniel J.

    2018-06-01

    Supermassive black hole binaries (SMBHBs) should be common in galactic nuclei as a result of frequent galaxy mergers. Recently, a large sample of sub-parsec SMBHB candidates was identified as bright periodically variable quasars in optical surveys. If the observed periodicity corresponds to the redshifted binary orbital period, the inferred orbital velocities are relativistic (v/c ≈ 0.1). The optical and ultraviolet (UV) luminosities are expected to arise from gas bound to the individual BHs, and would be modulated by the relativistic Doppler effect. The optical and UV light curves should vary in tandem with relative amplitudes which depend on the respective spectral slopes. We constructed a control sample of 42 quasars with aperiodic variability, to test whether this Doppler colour signature can be distinguished from intrinsic chromatic variability. We found that the Doppler signature can arise by chance in ˜20 per cent (˜37 per cent) of quasars in the nUV (fUV) band. These probabilities reflect the limited quality of the control sample and represent upper limits on how frequently quasars mimic the Doppler brightness+colour variations. We performed separate tests on the periodic quasar candidates, and found that for the majority, the Doppler boost hypothesis requires an unusually steep UV spectrum or an unexpectedly large BH mass and orbital velocity. We conclude that at most approximately one-third of these periodic candidates can harbor Doppler-modulated SMBHBs.

  2. Aortic isthmus Doppler velocimetry: role in assessment of preterm fetal growth restriction.

    LENUS (Irish Health Repository)

    Kennelly, M M

    2012-02-01

    Intrauterine fetal growth restriction (IUGR) is an important pregnancy complication associated with significant adverse clinical outcome, stillbirth, perinatal morbidity and cerebral palsy. To date, no uniformly accepted management protocol of Doppler surveillance that reduces mortality and cognitive morbidity has emerged. Aortic isthmus (AoI) evaluation has been proposed as a potential monitoring tool for IUGR fetuses. In this review, the current knowledge of the relationship between AoI Doppler velocimetry and preterm fetal growth restriction is reviewed. Relevant technical aspects and reproducibility data are reviewed as we discuss AoI Doppler and its place within the existing repertoire of Doppler assessments in placental insufficiency. The AoI is a link between the right and left ventricles which perfuse the lower and upper body, respectively. The clinical use of AoI waveforms for monitoring fetal deterioration in IUGR has been limited, but preliminary work suggests that abnormal AoI impedance indices are an intermediate step between placental insufficiency-hypoxemia and cardiac decompensation. Further prospective studies correlating AoI indices with arterial and venous Doppler indices and perinatal outcome are required before encorporating this index into clinical practice.

  3. Doppler-ultrasonographic finding of air in the portal vein: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ki Soon; Lee, Kwan Sup; Lee, Yul; Chung, Soo Young; Bae, Sang Hoon [College of Medicine, Hallym University, Seoul (Korea, Republic of)

    1994-03-15

    Classically air in the portal vein has been detected on plain radiography, but computed tomography and ultrasonography have been shown to be more sensitive. We report a case of air in the PV in a 10-day-old infant with pneumatosis intestinalis with its ultrasonographic and Doppler findings. The patient was a 10-day-old infant born by cesarean section at 41 weeks. Simple abdomen film revealed branching pattern of radiolucent air shadows within in contour of liver, gas distention of bowel loops and thickenod bowel walls with lincar intraluminal air shadows in abdomen, suggesting necrotizing enterocolitis. So we performed Doppler ultrasonography. Ultrasonography showed branching pattern of hyperechogenic dots and along the lumen of left portal vein. The color Doppler study revealed an aliasing duo to increased velocity and whirling pattern of blood flow, and the Duplex Doppler spectral display showed sharp, vertical bidirectional spikes by air in portal vein. Air in the portal vein can be easily diagnosed by the following signs: hyperechogenic dots in the portal vein on ultrasonography and vertical, sharp bidirectional spikes superimposed on the usual Doppler tracing of the portal vein on Duplex ultrasonography.

  4. Doppler-ultrasonographic finding of air in the portal vein: a case report

    International Nuclear Information System (INIS)

    Park, Ki Soon; Lee, Kwan Sup; Lee, Yul; Chung, Soo Young; Bae, Sang Hoon

    1994-01-01

    Classically air in the portal vein has been detected on plain radiography, but computed tomography and ultrasonography have been shown to be more sensitive. We report a case of air in the PV in a 10-day-old infant with pneumatosis intestinalis with its ultrasonographic and Doppler findings. The patient was a 10-day-old infant born by cesarean section at 41 weeks. Simple abdomen film revealed branching pattern of radiolucent air shadows within in contour of liver, gas distention of bowel loops and thickenod bowel walls with lincar intraluminal air shadows in abdomen, suggesting necrotizing enterocolitis. So we performed Doppler ultrasonography. Ultrasonography showed branching pattern of hyperechogenic dots and along the lumen of left portal vein. The color Doppler study revealed an aliasing duo to increased velocity and whirling pattern of blood flow, and the Duplex Doppler spectral display showed sharp, vertical bidirectional spikes by air in portal vein. Air in the portal vein can be easily diagnosed by the following signs: hyperechogenic dots in the portal vein on ultrasonography and vertical, sharp bidirectional spikes superimposed on the usual Doppler tracing of the portal vein on Duplex ultrasonography

  5. Ultrasonographic investigation of the Achilles tendon in elite badminton players using color Doppler.

    Science.gov (United States)

    Boesen, Morten Ilum; Boesen, Anders; Koenig, Merete Juhl; Bliddal, Henning; Torp-Pedersen, Soren

    2006-12-01

    The most frequent injuries in badminton players are in the lower extremities, especially in the Achilles tendon. The game of badminton may be related to abnormal intratendinous flow in the Achilles tendon as detected by color Doppler ultrasound. To a certain extent, this blood flow might be physiological, especially when examined after match. Cohort study (prevalence); Level of evidence, 3. Seventy-two elite badminton players were interviewed regarding Achilles tendon pain (achillodynia) in the preceding 3 years. Color Doppler was used to examine the tendons of 64 players before their matches and 46 players after their matches. Intratendinous color Doppler flow was graded from 0 to 4. The Achilles tendon was divided into dominant (eg, right side for right-handed players and vice versa) and nondominant side and classified as midtendon, preinsertional, and calcaneal areas. Of 72 players, 26 had experienced achillodynia in 34 tendons, 18 on the dominant side and 16 on the nondominant side. In 62% of the players with achillodynia, the problems had begun slowly, and the median duration of symptoms was 4 months (range, 0-36 months). Thirty-five percent had ongoing pain in their tendons for a median duration of 12 months (range, 0-12 months). Achillodynia was not associated with the self-reported training load or with sex, age, weight, singles or doubles players, or racket side. Forty-six players were scanned before and after match. At baseline, color Doppler flow was present in the majority of players, and only 7 (16%) players had no color Doppler flow in either tendon. After match, all players had some color Doppler flow in 1 or both tendons. Achillodynia and color Doppler flow were related in the nondominant Achilles tendon (chi-square, P = .008). The grades of Doppler flow also increased significantly after match in the preinsertional area in both the nondominant (P = .0002) and dominant (P = .005) side tendons. A large proportion of the players had experienced

  6. Effect of Doppler flow meter position on discharge measurement in surcharged manholes.

    Science.gov (United States)

    Yang, Haoming; Zhu, David Z; Liu, Yanchen

    2018-02-01

    Determining the proper installation location of flow meters is important for accurate measurement of discharge in sewer systems. In this study, flow field and flow regimes in two types of manholes under surcharged flow were investigated using a commercial computational fluid dynamics (CFD) code. The error in measuring the flow discharge using a Doppler flow meter (based on the velocity in a Doppler beam) was then estimated. The values of the corrective coefficient were obtained for the Doppler flow meter at different locations under various conditions. Suggestions for selecting installation positions are provided.

  7. Optical coherent control in semiconductors: Fringe contrast and inhomogeneous broadening

    DEFF Research Database (Denmark)

    Østergaard, John Erland; Vadim, Lyssenko; Hvam, Jørn Märcher

    2001-01-01

    in the interplay between the homogeneous and inhomogeneous broadenings are measured. Based on these experiments, a coherent control model describing the optical fringe contrast using different detection schemes, such as photoluminescence or four-wave mixing, is established. Significant spectral modulation...

  8. Correlation between Doppler flow patterns in growth-restricted fetuses and neonatal circulation

    NARCIS (Netherlands)

    Tanis, J. C.; Boelen, M. R.; Schmitz, D. M.; Casarella, L.; van der Laan, M. E.; Bos, A. F.; Bilardo, C. M.

    Objectives To investigate whether prenatal Doppler parameters in growth-restricted fetuses are correlated with neonatal circulatory changes. Methods In 43 cases of suspected fetal growth restriction (FGR), serial Doppler measurements of umbilical artery (UA) and middle cerebral artery (MCA)

  9. Towards Broadening the Audience

    Science.gov (United States)

    Sakimoto, P. J.

    2008-06-01

    The strand Towards Broadening the Audience was intended to seed thoughtful conversations about building bridges for outreach programs across cultural barriers. Many participants spoke about progress in increasing the diversity of their outreach audiences, but it was new voices from time-honored sources that offered fundamentally new wisdom. From the religious traditions and tensions that mark the Holy Land came the simple concept of bringing unity through teaching the commonalities found in basic concepts of the observed sky. From Mayan traditions, both contemporary and ancient, came the reminder that the sky is intimately connected to all aspects of our lives. Astronomy outreach should therefore be a part of much larger family and community celebrations. Ideas such as these offer renewed hope for major advances in bringing space science outreach to much broader audiences. They tell us about the importance of learning from voices with perspectives different from our own, and of building partnerships based upon genuine cross-cultural understanding and mutual love of the sky.

  10. An experimental investigation into power broadening of the Na-D lines in a flame

    International Nuclear Information System (INIS)

    Calcar, R.A. van.

    1980-01-01

    Investigations are described aimed at the verification of the existence of power broadening in fluorescence, as predicted by theory in the case of a broadband excitation source. Measurements were performed on a vapour of sodium (Na) atoms in a pre-mixed H 2 -O 2 -Ar flame under 1 atm pressure. The easily excited first resonance (or D) lines of Na were chosen for the observation of power broadening in fluorescence. (Auth.)

  11. Role of Doppler US and MRI in diagnosis of placenta accreta ...

    African Journals Online (AJOL)

    The aim of this work is to evaluate the role of Doppler US and MRI in the diagnosis of placenta accreta. Patients and methods: During period between 2012 to 2013, 120 pregnant patients with previous cesarean section were investigated by ultrasound and Doppler and then in suspected cases MRI was obtained (10 cases).

  12. Effect of the potential well on low temperature pressure broadening in CO-He

    Science.gov (United States)

    Palma, A.; Green, S.

    1986-01-01

    Previously reported low-temperature pressure-broadening calculations (Green, 1985) for CO-He interacting via an SCF-CI potential are compared with new calculations in which the attractive part of the potential is either reduced by half or eliminated entirely. Results demonstrate that the attractive well is responsible for low-temperature enhancement of pressure-broadening cross sections and suggest that agreement with recent experimental values at 4 K (Messer and DeLucia, 1984) can be obtained by a modest reduction, probably within the expected uncertainty, in the attractive part of the SCF-CI potential.

  13. Broadening of white-light continuum by filamentation in BK7 glass at its zero-dispersion point

    International Nuclear Information System (INIS)

    Jiang, Jiaming; Zhong, Yue; Zheng, Yinghui; Zeng, Zhinan; Ge, Xiaochun; Li, Ruxin

    2015-01-01

    Broadening of white-light continuum is observed by filamentation of near-infrared femtosecond laser pulses with peak power exceeding the megawatt level in BK7 glass with the presence of the zero-dispersion point. The simulated results show that, due to the low dispersion at the zero-dispersion point, the broadening of white-light continuum can be wider and the filament can persist in propagating stably longer distance. - Highlights: • We observed the white-light continuum by filamentation at the zero-dispersion point. • Peak power significantly exceeding the critical value of self-focusing was used. • Wider spectral broadening was obtained around the zero-dispersion point

  14. Phonon broadening in high entropy alloys

    Science.gov (United States)

    Körmann, Fritz; Ikeda, Yuji; Grabowski, Blazej; Sluiter, Marcel H. F.

    2017-09-01

    Refractory high entropy alloys feature outstanding properties making them a promising materials class for next-generation high-temperature applications. At high temperatures, materials properties are strongly affected by lattice vibrations (phonons). Phonons critically influence thermal stability, thermodynamic and elastic properties, as well as thermal conductivity. In contrast to perfect crystals and ordered alloys, the inherently present mass and force constant fluctuations in multi-component random alloys (high entropy alloys) can induce significant phonon scattering and broadening. Despite their importance, phonon scattering and broadening have so far only scarcely been investigated for high entropy alloys. We tackle this challenge from a theoretical perspective and employ ab initio calculations to systematically study the impact of force constant and mass fluctuations on the phonon spectral functions of 12 body-centered cubic random alloys, from binaries up to 5-component high entropy alloys, addressing the key question of how chemical complexity impacts phonons. We find that it is crucial to include both mass and force constant fluctuations. If one or the other is neglected, qualitatively wrong results can be obtained such as artificial phonon band gaps. We analyze how the results obtained for the phonons translate into thermodynamically integrated quantities, specifically the vibrational entropy. Changes in the vibrational entropy with increasing the number of elements can be as large as changes in the configurational entropy and are thus important for phase stability considerations. The set of studied alloys includes MoTa, MoTaNb, MoTaNbW, MoTaNbWV, VW, VWNb, VWTa, VWNbTa, VTaNbTi, VWNbTaTi, HfZrNb, HfMoTaTiZr.

  15. Kan Doppler-ultralyd erstatte strain gauge til måling af systolisk ankelblodtryk?

    DEFF Research Database (Denmark)

    Sørensen, T L; Perner, A; Hansen, L

    1992-01-01

    Traditionally, strain gauge technique is used in Denmark to measure ankle blood pressure, a method requiring both time and well-trained personnel. In a study involving 90 limbs in 45 patients, this method was compared with ultrasonic technique using a portable 5 MHz Doppler. The reproducibility...... of Doppler ankle pressure measurement was similar to that found in strain gauge based studies. Two consecutive measurements may differ by 20 mmHg or in terms of ankle-brachial index by 0.15 before this is considered significant. No systematic variation was found between the two methods. Increasing...... difficulties were encountered with the Doppler technique at pressures below 50 mmHg. It is concluded that Doppler is a good alternative to strain gauge for measurement of ankle blood pressure....

  16. Transcranial Doppler Ultrasound in Peninsular Arab Patients With Sickle Cell Disease.

    Science.gov (United States)

    Adekile, Adekunle; Hassan, Meaad; Asbeutah, Akram; Al-Hinai, Mohamed; Trad, Omar; Farhan, Nayef

    2018-05-06

    Transcranial Doppler ultrasound is used to identify patients with sickle cell disease (SCD) at risk for stroke. We performed transcranial Doppler studies in patients from 4 countries in the Arabian Peninsula (Kuwait, Oman, Iraq, and United Arab Emirates) to document the prevalence of abnormal transcranial Doppler findings. The patients were recruited from outpatient clinics and studied in a steady state. Transcranial Doppler examinations were performed with standard equipment by experienced operators. The time-averaged maximum mean velocity (TAMMV) was documented in the arteries of the circle of Willis. The hemoglobin (Hb) genotype was confirmed, and the fetal Hb level and complete blood counts were determined. There were 415 patients in the study, aged 2 to 18 years (mean ± SD, 8.6 ± 3.5 years). None of the patients had an abnormal TAMMV (ie, > 200 cm/s), whereas only 13 (3.1%), all from Iraq, had conditional values (170-200 cm/s) in the right middle cerebral artery and 7 (1.7%) in the left middle cerebral artery. There were no consistent TAMMV differences among male and female patients or in patients with different Hb genotypes (sickle cell anemia, sickle cell β 0- thalassemia, and sickle D). The use of hydroxyurea was associated with a lower TAMMV, whereas a blood transfusion history had no influence. Total hemoglobin, reticulocyte count, serum bilirubin, and fetal Hb values showed varying degrees of association with the TAMMV in the different vessels. This study has demonstrated the rarity of abnormal transcranial Doppler findings among Peninsular Arab patients with SCD. The guidelines for transcranial Doppler screening in this population need further studies and recommendations. © 2018 by the American Institute of Ultrasound in Medicine.

  17. Doppler echocardiographic predictors of mortality in female rats after myocardial infarction.

    Science.gov (United States)

    Santos, Alexandra Alberta; Helber, Izzo; Flumignan, Ronald L G; Antonio, Ednei L; Carvalho, Antonio C; Paola, Angelo A; Tucci, Paulo J; Moises, Valdir A

    2009-03-01

    Doppler echocardiogram is useful for the evaluation of anatomical and functional changes in late myocardial infarction (MI) in rats. However, no studies have evaluated the prognostic value of echocardiographic parameters 1 week after MI. Doppler echocardiogram was performed in 84 female Wistar rats 1 week after MI to determine infarction size, left chambers dimensions, fractional area change (FAC) of the left ventricle (LV), mitral inflow and tissue Doppler, myocardial performance index (MPI), and signs of pulmonary hypertension. The 365-day follow-up showed 53.6% mortality rate. Nonsurvivors showed larger (P or=0.60 (RR 3.49, 95% CI, 1.80-6.76), LV systolic area >or=0.26 cm(2) (RR 4.38, 95% CI, 1.88-10.21), E/E' ratio >or=20.3 (RR 2.12, 95% CI, 1.15-4.34), and E/A ratio associated with FAC (RR 2.99, 95% CI, 1.44-6.18). Some diastolic and systolic Doppler echocardiographic parameters in rats may be able to predict late mortality risk after MI.

  18. Computer-assisted quantitative assessment of power Doppler US: effects of microbubble contrast agent in the differentiation of breast tumors

    International Nuclear Information System (INIS)

    Kettenbach, Joachim; Helbich, Thomas H.; Huber, Sabine; Zuna, Ivan; Dock, Wolfgang

    2005-01-01

    Rationale and objectives: To objectively quantify the effects of a microbubble contrast agent to differentiate breast tumors with power doppler ultrasound and to compare these results with color doppler ultrasound (CD US). Methods: In 47 patients a microbubble contrast agent was injected intravenously. Computer-assisted quantitative assessment of the color pixel density was performed to evaluate the increase in Doppler signals. Results were compared to previously published results of a color Doppler ultrasound study. Results: Peak color pixel density at contrast-enhanced power Doppler ultrasound was higher for carcinomas than for benign tumors (P < 0.03). Time to peak enhancement was shorter in carcinomas than in benign tumors (P < 0.01). For both parameters, diagnostic accuracy of power Doppler ultrasound was 69 and 78%, and for color Doppler ultrasound 62 and 76%, respectively. Conclusions: Quantitative assessment of contrast-enhanced power Doppler ultrasound showed significant differences in malignant and benign breast tumors. Diagnostic accuracy of contrast-enhanced power Doppler ultrasound was higher compared to color Doppler ultrasound

  19. Doppler effect measurement in FCA assemblies X-3 and XI-1

    International Nuclear Information System (INIS)

    Okajima, Shigeaki; Mukaiyama, Takehiko

    1984-05-01

    Doppler reactivity worths were measured in FCA assemblies X-3 (mock-up core for JOYO Mark II) and XI-1 (mock-up core for large scale LMFBR) for U-238 and stractural materials of core (iron, stainless steel and nickel). The sample oscillation technique was used to measure the Doppler effect when a sample is heated up to 800 0 C from room temperature. The analysis was made using the 70 group JFS-3-J2 data set, and compared with the measured results. For U-238 samples, the calculation underestimates Doppler effects by 10%, on the other hand for other samples, the agreement between calculated values and measured values is quite good. (author)

  20. Vesico-ureteral reflux: diagnosis and staging with voiding color doppler US Preliminary experience

    International Nuclear Information System (INIS)

    Farina, Renato; Arena, Carmela; Pennisi, Francesco; Di Benedetto, Vincenzo; Politi, Guido; Di Benedetto, Aurelio

    2000-01-01

    Introduction: The aim of this study is to assess the accuracy of a new US examination: 'voiding color Doppler US ' in the early diagnosis and staging of vesico-ureteral reflux (VUR). The contrast agent US was SH U 508A (Levovist, Schering, Berlin), which produces a chromatic accentuation of the signals picked up by the color Doppler US. Eighteen patients (10 females, eight males) were recruited for the study. In two patients a second examination was performed for follow-up after a VUR conservative therapy. All patients were taken under examination for the evaluation of possible VUR. In all patients the voiding color Doppler US was followed by voiding cystourethrography (VCUG) and the data obtained were compared. Materials and methods: A total of 18 patients aged between 3 months and 10 years, were recruited for the study. The results of the examination were the following: urinary tract infections, follow-up of VUR after conservative or surgical therapy, miscellaneous indications. Voiding color Doppler US was performed, followed by a VCUG. The voiding color Doppler US consists in the trans-catheter introduction of a contrast agent SHU 508 A (Levovist, Schering, Ag. Berlin) into the bladder and a subsequent test with the color Doppler US to show or exclude the presence of reflux into the ureters and/or into the pyelo-caliceal cavity of the kidneys. After the introduction of the contrast agent US the ultrasound scanning of the bladder, the ureters and the pyelo-caliceal cavity was performed to examine the reflux degree. The ultrasonographic investigations were perfomed with AU 590 asyncronus US (Esaote Biomedica, Genova) with a 3.5 MHz convex probe. Results: After the trans-catheter introduction of the contrast agent US, vesico-ureteral reflux occured in 13 patients (77.2%). The reflux degree was also measured by means of ultrasound and was later confirmed by VCUG. The mean times of each examination were as follows: initial US, 10 min; catheterization, 8 min; voiding

  1. Doppler ultrasound study of penis in men with systemic sclerosis: a correlation with Doppler indices of renal and digital arteries.

    Science.gov (United States)

    Rosato, E; Barbano, B; Gigante, A; Cianci, R; Molinaro, I; Quarta, S; Digiulio, M A; Messineo, D; Pisarri, S; Salsano, F

    2013-01-01

    Erectile dysfunction (ED) prevalence in male systemic sclerosis (SSc) is high and its pathogenesis is unclear. The aim of the study is to assess correlation between Doppler ultrasound indices of penis and kidneys or digital arteries in male systemic sclerosis. Fourteen men with systemic sclerosis were enrolled in this study. Erectile function was investigated by the International Index of Erectile Function-5. Peak systolic velocity, end diastolic velocity, resistive index, pulsative index, and systolic/diastolic ratio were measured on the cavernous arteries at the peno-scrotal junction in the flaccid state, on the interlobar artery of both kidneys and all ten proper palmar digital arteries. Ten (71 percent) patients have an International Index of Erectile Function-5 less than 21. Reduction of penis peak systolic velocity was observed in all SSc subjects. Doppler indices of cavernous arteries correlate with the International Index of Erectile Function-5. The renal and digital arteries resistive index demonstrated a good correlation (p less than 0.0001) with International Index of Erectile Function-5. A positive correlation exists between penis and kidney arteries Doppler indices: end diastolic velocity (p less than 0.05, r=0.54), resistive index (p less than 0.0001, r=0.90), systolic/diastolic ratio (p less than 0.01, r=0.69). A positive correlation was observed between penis and digital arteries Doppler indices: peak systolic velocity (p less than 0.01, r=0.68), end diastolic velocity (p less than 0.01, r=0.75), resistive index (p less than 0.001, r=0.79), systolic/diastolic ratio (p less than 0.05, r=0.59). A correlation exists between arterial impairment of penis and renal or digital arteries.

  2. An ocean current inversion accuracy analysis based on a Doppler spectrum model

    Institute of Scientific and Technical Information of China (English)

    BAO Qingliu; ZHANG Youguang; LIN Mingsen; GONG Peng

    2017-01-01

    Microwave remote sensing is one of the most useful methods for observing the ocean parameters.The Doppler frequency or interferometric phase of the radar echoes can be used for an ocean surface current speed retrieval,which is widely used in spaceborne and airborne radars.While the effect of the ocean currents and waves is interactional.It is impossible to retrieve the ocean surface current speed from Doppler frequency shift directly.In order to study the relationship between the ocean surface current speed and the Doppler frequency shift,a numerical ocean surface Doppler spectrum model is established and validated with a reference.The input parameters of ocean Doppler spectrum include an ocean wave elevation model,a directional distribution function,and wind speed and direction.The suitable ocean wave elevation spectrum and the directional distribution function are selected by comparing the ocean Doppler spectrum in C band with an empirical geophysical model function (CDOP).What is more,the error sensitivities of ocean surface current speed to the wind speed and direction are analyzed.All these simulations are in Ku band.The simulation results show that the ocean surface current speed error is sensitive to the wind speed and direction errors.With VV polarization,the ocean surface current speed error is about 0.15 m/s when the wind speed error is 2 m/s,and the ocean surface current speed error is smaller than 0.3 m/s when the wind direction error is within 20° in the cross wind direction.

  3. Fresh look at the doppler changes in pregnancies with placental-based complications

    Directory of Open Access Journals (Sweden)

    S Dikshit

    2011-01-01

    Full Text Available Placental-based complications of pregnancy can be classified as acute and chronic. An example of acute placental complication is abruptio placenta. The chronic placental complications include pregnancy induced hypertension (PIH and idiopathic Intrauterine growth restriction (IUGR. The fetus is at risk for perinatal complications in both acute and chronic conditions. Here we take a look at the natural history of the Doppler parameters in chronic conditions. The techniques used for assessing the fetal well-being include, clinical methods, biophysical tests, conventional ultrasonography, and fetal Doppler studies. Arterial Doppler studies are used to assess the well-being of the fetus and to determine the timing of delivery. However, arterial Dopplers predict only the subset of fetuses at risk of having perinatal complications. Venous Dopplers have been used to improve upon the prognostication. However, by the time the commonly used venous Doppler signs, that is, ′A′ wave reversal in ductus venosus (DV is present, the fetus is likely to be already compromised. The fetus tries to adapt to the environment of deprivation by making a series of changes in the umbilical artery circulation, cerebral circulation, and hepatic circulation. As a result of these adaptations, the fetus overcomes the state of chronic hypoxia. This article takes a look at these changes and also the effect of these adaptations. It is suggested that serial comparisons of the venous flow characteristics of the DV and inferior vena cava (IVC can provide an early indication of the impending decompensation and can be used to predict the time the delivery.

  4. Line broadening interference for high-resolution nuclear magnetic resonance spectra under inhomogeneous magnetic fields

    International Nuclear Information System (INIS)

    Wei, Zhiliang; Yang, Jian; Lin, Yanqin; Chen, Zhong; Chen, Youhe

    2015-01-01

    Nuclear magnetic resonance spectroscopy serves as an important tool for analyzing chemicals and biological metabolites. However, its performance is subject to the magnetic-field homogeneity. Under inhomogeneous fields, peaks are broadened to overlap each other, introducing difficulties for assignments. Here, we propose a method termed as line broadening interference (LBI) to provide high-resolution information under inhomogeneous magnetic fields by employing certain gradients in the indirect dimension to interfere the magnetic-field inhomogeneity. The conventional spectral-line broadening is thus interfered to be non-diagonal, avoiding the overlapping among adjacent resonances. Furthermore, an inhomogeneity correction algorithm is developed based on pattern recognition to recover the high-resolution information from LBI spectra. Theoretical deductions are performed to offer systematic and detailed analyses on the proposed method. Moreover, experiments are conducted to prove the feasibility of the proposed method for yielding high-resolution spectra in inhomogeneous magnetic fields

  5. Submillimeter-wave measurements of the pressure broadening of BrO

    International Nuclear Information System (INIS)

    Yamada, M.M.; Kobayashi, M.; Habara, H.; Amano, T.; Drouin, B.J.

    2003-01-01

    The N 2 and O 2 pressure broadening coefficients of the J=23.5 ↔ 22.5 and J=25.5 ↔ 24.5 rotational transitions in the ground vibronic state X 2 Π 3/2 of 81 BrO at 624.768 and 650.178 GHz have been independently measured at Ibaraki University and Jet Propulsion Laboratory. These lines are expected to be monitored by the superconducting submillimeter-wave limb emission sounder in the Japanese Experiment Module on the International Space Station (JEM/SMILES) as well as the earth observing system microwave limb sounder (EOS-MLS). This work provides temperature-dependent pressure broadening parameters of BrO needed by the space station and satellite based observations. The BrO pressure broadening coefficients and their 1σ uncertainties are: γ 0 (N 2 )=3.24±0.05 MHz/Torr and γ 0 (O 2 )=2.33±0.06 MHz/Torr for the 624.768 GHz transition at room temperature (296 K). For the 650.178 GHz line, the results are: γ 0 (N 2 )=3.20±0.07 MHz/Torr and γ 0 (O 2 )=2.41±0.06 MHz/Torr. The temperature dependence exponents and their 1σ error are determined to be: n(N 2 )=-0.76±0.05 and n(O 2 )=-0.93±0.07 for the 624.768 GHz transition, and n(N 2 )=-0.84±0.07 and n(O 2 )=-0.70±0.07 for the 650.178 GHz transition

  6. Doppler color flow mapping of peripheral vessels: Comparison of angiodynography with conventional duplex US

    International Nuclear Information System (INIS)

    Merritt, C.R.B.; Bluth, E.I.; Sullivan, M.A.

    1986-01-01

    A new Doppler color flow imager was compared to duplex US in the evaluation of carotid and peripheral vessels in 50 patients. A 7.5-MHz transducer permitted simultaneous high-resolution real-time imaging of Doppler flow and tissue. The system was found to have excellent image quality and Doppler sensitivity. Flow characteristics and velocity measurements obtained with this system correlated well with those obtained using the duplex scanner and were obtained more quickly than with the conventional system, allowing more complete assessment of flow characteristics. Color Doppler flow imaging appears to be an extremely promising method for the rapid and effective evaluation of peripheral vascular flow

  7. Photon Sieve Bandwidth Broadening by Reduction of Chromatic Aberration Effects Using Second-Stage Diffractive Optics

    Science.gov (United States)

    2015-03-26

    to copyright protection in the United States. AFIT-ENP-MS-15-M-086 PHOTON SIEVE BANDWIDTH BROADENING BY REDUCTION OF CHROMATIC ABERRATION...RELEASE; DISTRIBUTION UNLIMITED. AFIT-ENP-MS-15-M-086 PHOTON SIEVE BANDWIDTH BROADENING BY REDUCTION OF CHROMATIC ABERRATION EFFECTS USING...A photon sieve is a lightweight diffractive optic which can be useful for space- based imaging applications. It is limited by chromatic

  8. Contrast-enhanced power Doppler US of hepatocellular carcinomas: Quantitative analysis

    International Nuclear Information System (INIS)

    Kim, Ah Young; Choi, Byung Ihn; Kim, Tae Kyoung; Lee, Kyoung Ho; Han, Joon Koo

    1999-01-01

    To determine peak time and duration of contrast enhancement of nodular hepatocellular carcinoma (HCC) on contrast-enhancement power Doppler ultrasound (US) with Levovist by quantitative analysis. Twenty eight patients with nodular HCC were prospectively evaluated with power Doppler US by one examiner. Serial images were obtained before and after injection of 300 mg/mL US contrast agent (SH U 508 A, Levovist, Schering) with the injection rate of 0.2 mL/sec. Power Doppler signals on obtained digital images were quantified using 'Ultrasound Imaging Tool Version 1.0' (Seoul, Korea). The grade, peak time and duration of contrast enhancement of the tumors were analyzed. For nodular HCCs, mean peak enhancement time was 60 seconds after injection of Levovist (mean enhanced area 41.6 ± 28.6 %). These tumoral enhancement decreased from 90 seconds and returned to near baseline state at 5 minutes after injection of Levovist. Maximum enhanced areas (%) were variable at a range of 8-98.5% and mean maximum enhanced area was 46.4 ± 28.6%. On contrast-enhanced power Doppler US with Levovist, nodular HCCs showed peak contrast enhancement (41.6± 28.6) at 60 seconds after injection of contrast agent. This tumoral enhancement nearly disappeared at 5 minutes after injection of contrast agent.

  9. Method and system of doppler correction for mobile communications systems

    Science.gov (United States)

    Georghiades, Costas N. (Inventor); Spasojevic, Predrag (Inventor)

    1999-01-01

    Doppler correction system and method comprising receiving a Doppler effected signal comprising a preamble signal (32). A delayed preamble signal (48) may be generated based on the preamble signal (32). The preamble signal (32) may be multiplied by the delayed preamble signal (48) to generate an in-phase preamble signal (60). The in-phase preamble signal (60) may be filtered to generate a substantially constant in-phase preamble signal (62). A plurality of samples of the substantially constant in-phase preamble signal (62) may be accumulated. A phase-shifted signal (76) may also be generated based on the preamble signal (32). The phase-shifted signal (76) may be multiplied by the delayed preamble signal (48) to generate an out-of-phase preamble signal (80). The out-of-phase preamble signal (80) may be filtered to generate a substantially constant out-of-phase preamble signal (82). A plurality of samples of the substantially constant out-of-phase signal (82) may be accumulated. A sum of the in-phase preamble samples and a sum of the out-of-phase preamble samples may be normalized relative to each other to generate an in-phase Doppler estimator (92) and an out-of-phase Doppler estimator (94).

  10. Three-dimensional Doppler ultrasound findings in healthy wrist and finger tendon sheaths

    DEFF Research Database (Denmark)

    Ammitzboll-Danielsen, Mads; Janta, Iustina; Torp-Pedersen, Søren

    2016-01-01

    interpretation of Doppler signals when diagnosing tenosynovitis. Method Forty healthy participants (20 women and 20 men age 23-67 years) without prior history of arthritis, tendon diseases or present pain in their hands were included. Twenty participants had 3D Doppler US of the second and third finger...... participant. No significant difference in feeding vessels was seen between the radial and carpal level in the wrist (p = 0.06) or between the second and third flexor tendon sheath (p = 0.84). Conclusion Doppler findings in or in close proximity to the tendon sheaths were common in wrists and fingers...

  11. Laser sub-Doppler cooling of atoms in an arbitrarily directed magnetic field

    International Nuclear Information System (INIS)

    Chang, Soo; Kwon, Taeg Yong; Lee, Ho Seong; Minogin, V.G.

    2002-01-01

    We analyze the influence of an arbitrarily directed uniform magnetic field on the laser sub-Doppler cooling of atoms. The analysis is done for a (3+5)-level atom excited by a σ + -σ - laser field configuration. Our analysis shows that the effects of the magnetic field depend strongly on the direction of the magnetic field. In an arbitrarily directed magnetic field the laser cooling configuration produces both the main resonance existing already at zero magnetic field and additional sub-Doppler resonances caused by two-photon and higher-order multiphoton processes. These sub-Doppler resonances are, however, well separated on the velocity scale if the Zeeman shift exceeds the widths of the resonances. This allows one to use the main sub-Doppler resonance for an effective laser cooling of atoms even in the presence of the magnetic field. The effective temperature of the atomic ensemble at the velocity of the main resonance is found to be almost the same as in the absence of the magnetic field. The defined structure of the multiphoton resonances may be of importance for the sub-Doppler laser cooling of atoms, atomic extraction from magneto-optical traps, and applications related to the control of atomic motion

  12. A broadened typology on energy and security

    International Nuclear Information System (INIS)

    Johansson, Bengt

    2013-01-01

    A broadened typology describing the interconnection between energy and security is developed in this paper, with the aim of improving understanding of the relationship between energy and security by applying different research and policy perspectives. One approach involves studying energy as an object exposed to security threats, using concepts such as security of supply or security of demand. Another approach involves studying the role of the energy system as the subject in generating or enhancing insecurity. The latter approach includes studying the conflict-generating potential inherent in the economic value of energy, the risk of accidents and antagonistic attacks to energy infrastructure and the security risks related to the negative environmental impact of the energy system. In order to make a comprehensive analysis of the security consequences of proposed energy policies or strategies, all these aspects should be taken into account to varying degrees. The typology proposed here could be a valuable tool for ensuring that all security aspects have been considered. - Highlights: • The paper presents a broadened typology of energy and security, useful for policy analysis. • The energy system can be an object for security threats and as a subject generating or contributing to insecurity. • Energy as an object for security threats includes the concepts of security of supply and security of demand. • The economic value of energy can contribute to insecurity. • Technological and environmental risks of specific energy systems also provide potential threats to human security

  13. The effect of line-broadening on the overall width of transition arrays in dense plasmas

    International Nuclear Information System (INIS)

    Hoarty, D.J.; Bentley, C.D.; Crowley, B.J.B.; Davidson, S.J.; Gales, S.G.; Graham, P.; Harris, J.W.O.; Iglesias, C.A.; James, S.F.; Smith, C.C.

    2006-01-01

    Experiments have been performed, using the HELEN laser, to measure absorption spectra in the temperature range 20-60 eV and density range 0.5-3 g/cm 3 . K-shell spectra of aluminium were studied to investigate the effect of the plasma environment on the absorption spectrum. The experiments show the effect, at high-density, of array broadening and the merging of high series lines. Comparisons of the experimental absorption data to different opacity models are discussed. The experimental data are compared to calculations of the CASSANDRA opacity model, with and without the inclusion of electron impact broadening. The CASSANDRA code is in better agreement with experiment with electron impact broadening included. The data were also compared to the OPAL detailed term accounting model with reasonable agreement

  14. Optimized variational analysis scheme of single Doppler radar wind data

    Science.gov (United States)

    Sasaki, Yoshi K.; Allen, Steve; Mizuno, Koki; Whitehead, Victor; Wilk, Kenneth E.

    1989-01-01

    A computer scheme for extracting singularities has been developed and applied to single Doppler radar wind data. The scheme is planned for use in real-time wind and singularity analysis and forecasting. The method, known as Doppler Operational Variational Extraction of Singularities is outlined, focusing on the principle of local symmetry. Results are presented from the application of the scheme to a storm-generated gust front in Oklahoma on May 28, 1987.

  15. Method and apparatus for Doppler frequency modulation of radiation

    Science.gov (United States)

    Margolis, J. S.; Mccleese, D. J.; Shumate, M. S.; Seaman, C. H. (Inventor)

    1980-01-01

    A method and apparatus are described for frequency modulating radiation, such as from a laser, for optoacoustic detectors, interferometers, heterodyne spectrometers, and similar devices. Two oppositely reciprocating cats-eye retroreflectors are used to Doppler modulate the radiation. By reciprocally moving both retroreflectors, the center of mass is maintained constant to permit smooth operation at many Hertz. By slightly offsetting the axis of one retroreflector relative to the other, multiple passes of a light beam may be achieved for greater Doppler shifts with the same reciprocating motion of the retroreflectors.

  16. Analysis of multiple scattering effects in optical Doppler tomography

    DEFF Research Database (Denmark)

    Yura, H.T.; Thrane, L.; Andersen, Peter E.

    2005-01-01

    Optical Doppler tomography (ODT) combines Doppler velocimetry and optical coherence tomography (OCT) to obtain high-resolution cross-sectional imaging of particle flow velocity in scattering media such as the human retina and skin. Here, we present the results of a theoretical analysis of ODT where...... multiple scattering effects are included. The purpose of this analysis is to determine how multiple scattering affects the estimation of the depth-resolved localized flow velocity. Depth-resolved velocity estimates are obtained directly from the corresponding mean or standard deviation of the observed...

  17. Calculation results and experimental testing of doppler feedback coefficients

    International Nuclear Information System (INIS)

    Yang Shunhai

    1989-01-01

    The Doppler feedback coefficients are calculated by the interpolation and group collapsing method from multigroup self-shielding factors and infinite dilution cross sections rather than effective resonance integrals by using resonance data base. Since many updated sets of multigroup data are in existence to be selected, the calculation process can be simplified. The heterogeneous effects are taken into account by equivalence relation. The computer code of Doppler feedback coefficients is created on computer CYBER-825 and PDP-11. The results calculated are in good agreement with the experiments

  18. The use of contrast-enhanced color doppler ultrasound in the differentiation of retinal detachment from vitreous membrane

    International Nuclear Information System (INIS)

    Han, Sang Suk; Chang, Seung Kook; Yoon, Jung Hee; Lee, Young Joon

    2001-01-01

    To compare the clinical utility of contrast-enhanced color Doppler US in the differentiation of retinal detachment (RD) from vitreous membrane (VM) with that of various conventional US modalities, and to analyze the enhancement patterns in cases showing an enhancement effect. In 32 eyes examined over a recent two-year period, RD (n=14) and VM (n=18) were confirmed by surgery (n=28) or clinical follow-up (n=4). In all cases, gray-scale, color Doppler, and power Doppler US were performed prior to contrast injection, and after the intravenous injection of Levovist (Schering, Berlin) by hand for 30 seconds at a dose of 2.5 g and a concentration of 300 mg/mL via an antecubital vein, contrast-enhanced color Doppler US was performed. At Doppler US, the diagnostic criterion for RD and VM was whether or not color signals were visualized in membranous structures. Diagnostic accuracy was 78% at gray-scale US, 81% at color Doppler US, 59% at power Doppler US, and 97% at contrast-enhanced color Doppler US. The sensitivity of color Doppler US to color signals in RD increased from 57% to 93% after contrast enhancement. The enhancement patterns observed were signal accentuation (n=3), signal extension (n=2), signal addition (n=3), and new signal visualization (n=5). Contrast-enhanced color Doppler US was the most accurate US modality for differentiating RD from VM, showing a significantly increased signal detection rate in RD

  19. Laser Doppler thermometry in flat flames

    NARCIS (Netherlands)

    Maaren, van A.; Goey, de L.P.H.

    1994-01-01

    Laser Doppler Velocimetry measurements are performed in flat flames, stabilized on a newly developed flat-flame burner. It is shown that the velocity component perpendicular to the main flow direction, induced by expansion in the reaction zone and buoyancy in the burnt gas, is significant. A method

  20. Renal duplex Doppler ultrasound findings in diabetics

    International Nuclear Information System (INIS)

    Shim, Hyang Yee; Kim, Young Geun; Kook, Cheol Keu; Yoon, Chong Hyun; Lee, Shin Hyung; Lee, Chang Joon

    1993-01-01

    The correlation between clinical-laboratory findings and renal duplex Doppler ultrasound findings was studied in 45 patients with diabetes mellitus to see the role of duplex Doppler ultrasound in the detection of diabetic nephropathy. The resistive indices in patients with elevated serum creatinine, BUN, proteinuria, and systolic blood pressure levels were statistically significantly higher than those in patients with normal levels (p<0.05). Also resistive indics in patients with retinopathy were higher than that in patients without retinopathy (p<0.05). But the ultrasound morphologic changes of kidney such as renal length, cortical eye-catching, and corticomedullarycontrast were not well correlated with clinical-laboratory data and resistive index. The resistive index of the kidney in conjunction with clinical-laboratory data in diabetics may be helpful in the evaluation of diabetic nephropathy

  1. Renal duplex Doppler ultrasound findings in diabetics

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Hyang Yee; Kim, Young Geun; Kook, Cheol Keu; Yoon, Chong Hyun; Lee, Shin Hyung; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    1993-12-15

    The correlation between clinical-laboratory findings and renal duplex Doppler ultrasound findings was studied in 45 patients with diabetes mellitus to see the role of duplex Doppler ultrasound in the detection of diabetic nephropathy. The resistive indices in patients with elevated serum creatinine, BUN, proteinuria, and systolic blood pressure levels were statistically significantly higher than those in patients with normal levels (p<0.05). Also resistive indics in patients with retinopathy were higher than that in patients without retinopathy (p<0.05). But the ultrasound morphologic changes of kidney such as renal length, cortical eye-catching, and corticomedullarycontrast were not well correlated with clinical-laboratory data and resistive index. The resistive index of the kidney in conjunction with clinical-laboratory data in diabetics may be helpful in the evaluation of diabetic nephropathy

  2. The color Doppler ultrasonography in in the diagnosis of deep vein thrombosis

    International Nuclear Information System (INIS)

    Ameneiro Perez, Santiago; Alvarez Sanchez, Jose A.; Rodriguez Villalonga, Luis; Borras Migues, Marisela; Quinnones Castro, Mayda

    2004-01-01

    The paper was aimed at evaluating the accuracy of color Doppler ultrasonography, a noninvasive method, in the diagnosis of deep vein thrombosis of the lower limbs, comparing it to the results of the cruel and costly diagnostic g olden rule , that is, phlebography. Methods: Color Doppler ultrasonography served to assess 102 patients clinically suspected of deep vein thrombosis of the lower limbs, taking into account the following criteria: vein compressibility, echographic images, color, Vein Doppler signal modulation after several maneuvers and distal compression. Sensitivity, specificity, positive and negative predictive values and diagnostic efficacy were estimated for each criteria, taking the phlebography as a reference. Results: Total or partial lack of vein compressibility combined with the vein flow evaluation is the ultrasonographic criterion that reveals higher degree of sensitivity, specificity and efficacy (0,98; 0,95 and 0,97 respectively. Color Doppler ultrasonography is a highly effective noninvasive diagnostic method that detects deep vein thrombosis in proximal areas of the lower limbs

  3. Accuracy of doppler ultrasound in diagnosis of endometrial carcinoma

    International Nuclear Information System (INIS)

    Batool, S.; Raza, S.; Manzur, S.

    2013-01-01

    Objective: To determine the accuracy of Doppler ultrasound in the diagnosis of endometrial carcinoma in patients presenting with post-menopausal bleeding while taking histopathological findings as the gold standard. Methods: The cross-sectional study was done at the Department of Radiology, Bahawal Victoria Hospital, Bahawalpur, from April 1 to September 30, 2009, and comprised 128 patients above 50 years of age having history of post-menopausal bleeding and who were referred to the department. Name, age and hospital registration number were recorded on a proforma. Doppler ultrasound was performed and endometrial thickness and uterine artery resistive index were recorded on transabdominal ultrasonography. Patients with endometrial thickness of more than 5mm and uterine artery resistive index of less than 0.7 were considered to be having endometrial carcinoma. Histopathology findings were also recorded using the hospital registration number of the patient. The findings of Doppler ultrasound scan were validated with the findings of histopathology. Results: Of the 128 patients, 48 (37.5%) were between the ages of 51 and 55 years; 46 (35.93%) were in the 56-60 age group; and 34 (26.57%) were over 65 years. On the basis of Doppler ultrasound findings, 106 (82.8%) patients were diagnosed as having endometrial carcinoma, while 22 (17.19%) were declared negative. Ultrasonography results were compared with histopathology findings. The percentages of true positive, true negative, false positive and false negative were calculated. There were 103 (80.47%) true positive; 12 (9.37%) false positive; 10 (7.81%) true negative; and 3 (2.35%) false negative. Specificity, sensitivity, positive predictive value and negative predictive value were found to be 97.16%, 76%, 89.56% and 76.92% respectively. Conclusion: The use of Doppler ultrasonography in non-invasive diagnosis of endometrial carcinoma in patients presenting with post-menopausal bleeding was quite useful with good

  4. Operator auditory perception and spectral quantification of umbilical artery Doppler ultrasound signals.

    Directory of Open Access Journals (Sweden)

    Ann Thuring

    Full Text Available OBJECTIVE: An experienced sonographer can by listening to the Doppler audio signals perceive various timbres that distinguish different types of umbilical artery flow despite an unchanged pulsatility index (PI. Our aim was to develop an objective measure of the Doppler audio signals recorded from fetoplacental circulation in a sheep model. METHODS: Various degrees of pathological flow velocity waveforms in the umbilical artery, similar to those in human complicated pregnancies, were induced by microsphere embolization of the placental bed (embolization model, 7 lamb fetuses, 370 Doppler recordings or by fetal hemodilution (anemia model, 4 lamb fetuses, 184 recordings. A subjective 11-step operator auditory scale (OAS was related to conventional Doppler parameters, PI and time average mean velocity (TAM, and to sound frequency analysis of Doppler signals (sound frequency with the maximum energy content [MAXpeak] and frequency band at maximum level minus 15 dB [MAXpeak-15 dB] over several heart cycles. RESULTS: WE FOUND A NEGATIVE CORRELATION BETWEEN THE OAS AND PI: median Rho -0.73 (range -0.35- -0.94 and -0.68 (range -0.57- -0.78 in the two lamb models, respectively. There was a positive correlation between OAS and TAM in both models: median Rho 0.80 (range 0.58-0.95 and 0.90 (range 0.78-0.95, respectively. A strong correlation was found between TAM and the results of sound spectrum analysis; in the embolization model the median r was 0.91 (range 0.88-0.97 for MAXpeak and 0.91 (range 0.82-0.98 for MAXpeak-15 dB. In the anemia model, the corresponding values were 0.92 (range 0.78-0.96 and 0.96 (range 0.89-0.98, respectively. CONCLUSION: Audio-spectrum analysis reflects the subjective perception of Doppler sound signals in the umbilical artery and has a strong correlation to TAM-velocity. This information might be of importance for clinical management of complicated pregnancies as an addition to conventional Doppler parameters.

  5. Normal Doppler velocimetry of renal vasculature in Persian cats.

    Science.gov (United States)

    Carvalho, Cibele F; Chammas, Maria C

    2011-06-01

    Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n=50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17±13.46 cm/s and 0.38±0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15±0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17±9.40 cm/s and 0.54±0.07. The RA had a mean ESA of 1.12±1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828±0.296. The IA showed PSV and RI values of 32.16±9.33 cm/s and 0.52±0.06, respectively. The mean ESA of all IAs was 0.73±0.61 m/s(2). The calculated upper limit of the reference value was 2.0m

  6. BROADENING OF BALMER LINES FOR HIGH QUANTUM NUMBER

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, B. H.

    1963-10-15

    It is shown that the impact theory breakdown at sufficiently large distances from the line center in effect lowers the principle quantum number at which electron broadening might otherwise be assumed to dominate. Since the impact theory breaks down and effectively the impact widths decrease progressively for the line components more distant from the center, the contributions of the components to the folding integral decrease rapidly except at their own positions. (R.E.U.)

  7. Low-frequency high-definition power Doppler in visualizing and defining fetal pulmonary venous connections.

    Science.gov (United States)

    Liu, Lin; He, Yihua; Li, Zhian; Gu, Xiaoyan; Zhang, Ye; Zhang, Lianzhong

    2014-07-01

    The use of low-frequency high-definition power Doppler in assessing and defining pulmonary venous connections was investigated. Study A included 260 fetuses at gestational ages ranging from 18 to 36 weeks. Pulmonary veins were assessed by performing two-dimensional B-mode imaging, color Doppler flow imaging (CDFI), and low-frequency high-definition power Doppler. A score of 1 was assigned if one pulmonary vein was visualized, 2 if two pulmonary veins were visualized, 3 if three pulmonary veins were visualized, and 4 if four pulmonary veins were visualized. The detection rate between Exam-1 and Exam-2 (intra-observer variability) and between Exam-1 and Exam-3 (inter-observer variability) was compared. In study B, five cases with abnormal pulmonary venous connection were diagnosed and compared to their anatomical examination. In study A, there was a significant difference between CDFI and low-frequency high-definition power Doppler for the four pulmonary veins observed (P low-frequency high-definition power Doppler was higher than that when employing two-dimensional B-mode imaging or CDFI. There was no significant difference between the intra- and inter-observer variabilities using low-frequency high-definition power Doppler display of pulmonary veins (P > 0.05). The coefficient correlation between Exam-1 and Exam-2 was 0.844, and the coefficient correlation between Exam-1 and Exam-3 was 0.821. In study B, one case of total anomalous pulmonary venous return and four cases of partial anomalous pulmonary venous return were diagnosed by low-frequency high-definition power Doppler and confirmed by autopsy. The assessment of pulmonary venous connections by low-frequency high-definition power Doppler is advantageous. Pulmonary venous anatomy can and should be monitored during fetal heart examination.

  8. In-medium jet evolution: interplay between broadening and decoherence effects

    CERN Document Server

    Apolinário, Liliana; Milhano, Guilherme; Salgado, Carlos A.

    2016-01-01

    The description of the modifications of the coherence pattern in a parton shower, in the presence of a QGP, has been actively addressed in recent studies. Among the several achievements, finite energy corrections, transverse momentum broadening due to medium interactions and interference effects between successive emissions have been extensively improved as they seem to be essential features for a correct description of the results obtained in heavy-ion collisions. In this work, based on the insights of our previous work [1], we explore the physical interplay between broadening and decoherence, by generalising previous studies of medium-modifications of the antenna spectrum [2, 3, 4] - so far restricted to the case where transverse motion is neglected. The result allow us to identify two quantities controlling the decoherence of a medium modified shower that can be used as building blocks for a successful future generation of jet quenching Monte Carlo simulators: a generalisation of the $\\Delta_{med}$ paramet...

  9. A faster procedure for the calculation of the J({xi}, {beta}) function

    Energy Technology Data Exchange (ETDEWEB)

    Pinheiro Palma, Daniel Artur [Instituto Federal de Educacao, Ciencia e Tecnologia do Rio de Janeiro, 28630-050 Rio de Janeiro, RJ (Brazil); COPPE/UFRJ - Programa de Engenharia Nuclear, 21941-914 Rio de Janeiro, RJ (Brazil)], E-mail: dpalma@cefeteq.br; Senra Martinez, Aquilino [Instituto Federal de Educacao, Ciencia e Tecnologia do Rio de Janeiro, 28630-050 Rio de Janeiro, RJ (Brazil); COPPE/UFRJ - Programa de Engenharia Nuclear, 21941-914 Rio de Janeiro, RJ (Brazil)], E-mail: aquilino@lmp.ufrj.br

    2009-10-15

    One of the biggest difficulties in obtaining an analytical expression for the J({xi}, {beta}) function is its explicit dependence on the Doppler broadening function {psi}(x,{xi}). The objective of this paper is to present a method for the fast and accurate calculation for the J({xi}, {beta}) function based on the recent advances in the calculation of the Doppler broadening function and on a systematic analysis of its integrand. The methodology proposed uses an analytical formulation for the calculation of {psi}(x, {xi}) and a representation in series for error functions with complex argument. The results were satisfactory from the accuracy and processing time standpoint and are an option to other calculation methods found in the literature.

  10. A faster procedure for the calculation of the J(ξ, β) function

    International Nuclear Information System (INIS)

    Pinheiro Palma, Daniel Artur; Senra Martinez, Aquilino

    2009-01-01

    One of the biggest difficulties in obtaining an analytical expression for the J(ξ, β) function is its explicit dependence on the Doppler broadening function ψ(x,ξ). The objective of this paper is to present a method for the fast and accurate calculation for the J(ξ, β) function based on the recent advances in the calculation of the Doppler broadening function and on a systematic analysis of its integrand. The methodology proposed uses an analytical formulation for the calculation of ψ(x, ξ) and a representation in series for error functions with complex argument. The results were satisfactory from the accuracy and processing time standpoint and are an option to other calculation methods found in the literature.

  11. Positronic probe of vacancy defects on surfaces of Au nanoparticles embedded in MgO

    International Nuclear Information System (INIS)

    Xu, Jun; Moxom, J.; Somieski, B.; White, C. W.; Mills, A. P.; Suzuki, R.; Ishibashi, S.

    2001-01-01

    Clusters of four atomic vacancies were found in Au nanoparticle-embedded MgO by positron lifetime spectroscopy [Phys. Rev. Lett. 83, 4586 (1999)]. These clusters were also suggested to locate at the surface of Au nanoparticles by one-detector measurements of Doppler broadening of annihilation radiation. In this work we provide evidence, using two-detector coincidence experiments of Doppler broadening (2D-DBAR), to clarify that these vacancy clusters reside on the surfaces of Au nanoparticles. This work also demonstrates a method for identifying defects at nanomaterials interfaces: a combination of both positron lifetime spectroscopy, which tells the type of the defects, and 2D-DBAR measurements, which reveals chemical environment of the defects

  12. Positronic probe of vacancy defects on surfaces of Au nanoparticles embedded in MgO

    Science.gov (United States)

    Xu, Jun; Moxom, J.; Somieski, B.; White, C. W.; Mills, A. P., Jr.; Suzuki, R.; Ishibashi, S.

    2001-09-01

    Clusters of four atomic vacancies were found in Au nanoparticle-embedded MgO by positron lifetime spectroscopy [Phys. Rev. Lett. 83, 4586 (1999)]. These clusters were also suggested to locate at the surface of Au nanoparticles by one-detector measurements of Doppler broadening of annihilation radiation. In this work we provide evidence, using two-detector coincidence experiments of Doppler broadening (2D-DBAR), to clarify that these vacancy clusters reside on the surfaces of Au nanoparticles. This work also demonstrates a method for identifying defects at nanomaterials interfaces: a combination of both positron lifetime spectroscopy, which tells the type of the defects, and 2D-DBAR measurements, which reveals chemical environment of the defects.

  13. Observation of transient lattice vacancies produced during high-energy ion irradiation of Ni foils

    International Nuclear Information System (INIS)

    Tsuchida, Hidetsugu; Iwai, Takeo; Awano, Misa; Kishida, Mutsumi; Katayama, Ichiro; Jeong, Sun-Chang; Ogawa, Hidemi; Sakamoto, Naoki; Komatsu, Masao; Itoh, Akio

    2007-01-01

    Real-time positron annihilation spectroscopy has been applied for the first time for the investigation of lattice vacancies produced during ion irradiation. Measurements were performed for thin nickel foils irradiated with 2.5 MeV C ions. Doppler broadenings of positron annihilation γ-rays were measured alternately during beam-on and beam-off conditions. It was found that the Doppler broadening line-shape parameter measured during irradiation is larger than those obtained before and after irradiation. This evidently implies that transient or non-survivable vacancy defects are produced during ion irradiation. On the other hand, no such significant change in the line-shape parameter was observed for other face-centred-cubic metal forms of aluminium

  14. Theory of strongly saturated double-resonance line shapes in arbitrary angular momentum states of molecules

    International Nuclear Information System (INIS)

    Galbraith, H.W.; Dubs, M.; Steinfeld, J.I.

    1982-01-01

    We calculate the steady-state probe absorption line-shape function for a strongly driven, Zeeman-degenerate molecular system. The probe laser is treated to lowest order while the pump laser is dealt with to all orders. We obtain the probe line shape for the cases of parallel and perpendicular linear polarization of the two lasers. As expected, the effects of M degeneracy, as well as differences due to the relative laser polarizations, are most pronounced when Doppler broadening is not important. However, even in the presence of large Doppler broadening we find a narrowing of the population hole by including the Zeeman degeneracy and a further narrowing if perpendicular laser polarizations are used

  15. Glare Spot Phase Doppler Anemometry

    Science.gov (United States)

    Hespel, Camille; Ren, Kuanfang; Gréhan, Gérard; Onofri, Fabrice

    2007-06-01

    The Phase Doppler anemometry has been developed to measure simultaneously the velocity and the size of droplets. The measurement of the refractive index would be also interesting since it depends on the temperature and the composition of the particle and its measurement permits both to increase the quality of the diameter measurement and to obtain information on the temperature and/or the composition of the droplets. In this paper, we introduce a Glare Spot Phase Doppler Anemometry which uses two large beams. In this case, the images of the particle formed by the reflected and refracted light, known as glare spots, are separated in space. When a particle passes in the probe volume, the two parts in a signal obtained by a detector in forward direction are then separated in time. If two detectors are used the phase differences between two signals, the distance and the intensity ratio of reflected and refracted parts can be obtained and they provide rich information about the particle diameter and its refractive index, as well as its velocity. This paper is devoted to the numerical study of such a configuration with two theoretical models: geometrical optics and rigorous electromagnetism solution.

  16. Two-dimensional intraventricular flow mapping by digital processing conventional color-Doppler echocardiography images.

    Science.gov (United States)

    Garcia, Damien; Del Alamo, Juan C; Tanne, David; Yotti, Raquel; Cortina, Cristina; Bertrand, Eric; Antoranz, José Carlos; Perez-David, Esther; Rieu, Régis; Fernandez-Aviles, Francisco; Bermejo, Javier

    2010-10-01

    Doppler echocardiography remains the most extended clinical modality for the evaluation of left ventricular (LV) function. Current Doppler ultrasound methods, however, are limited to the representation of a single flow velocity component. We thus developed a novel technique to construct 2D time-resolved (2D+t) LV velocity fields from conventional transthoracic clinical acquisitions. Combining color-Doppler velocities with LV wall positions, the cross-beam blood velocities were calculated using the continuity equation under a planar flow assumption. To validate the algorithm, 2D Doppler flow mapping and laser particle image velocimetry (PIV) measurements were carried out in an atrio-ventricular duplicator. Phase-contrast magnetic resonance (MR) acquisitions were used to measure in vivo the error due to the 2D flow assumption and to potential scan-plane misalignment. Finally, the applicability of the Doppler technique was tested in the clinical setting. In vitro experiments demonstrated that the new method yields an accurate quantitative description of the main vortex that forms during the cardiac cycle (mean error for vortex radius, position and circulation). MR image analysis evidenced that the error due to the planar flow assumption is close to 15% and does not preclude the characterization of major vortex properties neither in the normal nor in the dilated LV. These results are yet to be confirmed by a head-to-head clinical validation study. Clinical Doppler studies showed that the method is readily applicable and that a single large anterograde vortex develops in the healthy ventricle while supplementary retrograde swirling structures may appear in the diseased heart. The proposed echocardiographic method based on the continuity equation is fast, clinically-compliant and does not require complex training. This technique will potentially enable investigators to study of additional quantitative aspects of intraventricular flow dynamics in the clinical setting by

  17. Brazilian Guidelines for transcranial doppler in children and adolescents with sickle cell disease

    Directory of Open Access Journals (Sweden)

    Clarisse Lopes de Castro Lobo

    2011-02-01

    Full Text Available BACKGROUND: Sickle cell disease is the most common monogenic hereditary disease in Brazil. Although strokes are one of the main causes of morbidity and mortality in these patients, the use of transcranial Doppler to identify children at risk is not universally used. OBJECTIVE: To develop Brazilian guidelines for the use of transcranial Doppler in sickle cell disease children and adolescents, so that related health policies can be expanded, and thus contribute to reduce morbidity and mortality. METHODS: The guidelines were formulated in a consensus meeting of experts in transcranial Doppler and sickle cell disease. The issues discussed were previously formulated and scientific articles in databases (MEDLINE, SciELO and Cochrane were carefully analyzed. The consensus for each question was obtained by a vote of experts on the specific theme. RESULTS: Recommendations were made, including indications for the use of transcranial Doppler according to the sickle cell disease genotype and patients age; the necessary conditions to perform the exam and its periodicity depending on exam results; the criteria for the indication of blood transfusions and iron chelation therapy; the indication of hydroxyurea; and the therapeutic approach in cases of conditional transcranial Doppler. CONCLUSION: The Brazilian guidelines on the use of transcranial doppler in sickle cell disease patients may reduce the risk of strokes, and thus reduce the morbidity and mortality and improve the quality of life of sickle cell disease patients.

  18. Evaluation of factors influencing arterial Doppler waveforms in an in vitro flow phantom

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Chang Kyu [Dept. of Radiology, SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul (Korea, Republic of); Lee, Kyoung Ho [Dept. of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); Kim, Seung Hyup [Dept. of Radiology and the Institute of Radiation Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2017-01-15

    The aim of this study was to investigate factors that influence arterial Doppler waveforms in an in vitro phantom to provide a more accurate and comprehensive explanation of the Doppler signal. A flow model was created using a pulsatile artificial heart, rubber or polyethylene tubes, a water tank, and a glass tube. Spectral Doppler tracings were obtained in multiple combinations of compliance, resistance, and pulse rate. Peak systolic velocity, minimum diastolic velocity, resistive index (RI), pulsatility index, early systolic acceleration time, and acceleration index were measured. On the basis of these measurements, the influences of the variables on the Doppler waveforms were analyzed. With increasing distal resistance, the RI increased in a relatively linear relationship. With increasing proximal resistance, the RI decreased. The pulsus tardus and parvus phenomenon was observed with a small acceleration index in the model with a higher grade of stenosis. An increase in the distal resistance masked the pulsus tardus and parvus phenomenon by increasing the acceleration index. Although this phenomenon occurred independently of compliance, changes in the compliance of proximal or distal tubes caused significant changes in the Doppler waveform. There was a reverse relationship between the RI and the pulse rate. Resistance and compliance can alter the Doppler waveforms independently. The pulse rate is an extrinsic factor that also influences the RI. The compliance and distal resistance, as well as proximal resistance, influence the pulsus tardus and parvus phenomenon.

  19. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    International Nuclear Information System (INIS)

    Ayaz, Tunahan; Akansel, Gur.; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-01-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia

  20. Airborne Doppler Wind Lidar Post Data Processing Software DAPS-LV

    Science.gov (United States)

    Beyon, Jeffrey Y. (Inventor); Koch, Grady J. (Inventor); Kavaya, Michael J. (Inventor)

    2015-01-01

    Systems, methods, and devices of the present invention enable post processing of airborne Doppler wind LIDAR data. In an embodiment, airborne Doppler wind LIDAR data software written in LabVIEW may be provided and may run two versions of different airborne wind profiling algorithms. A first algorithm may be the Airborne Wind Profiling Algorithm for Doppler Wind LIDAR ("APOLO") using airborne wind LIDAR data from two orthogonal directions to estimate wind parameters, and a second algorithm may be a five direction based method using pseudo inverse functions to estimate wind parameters. The various embodiments may enable wind profiles to be compared using different algorithms, may enable wind profile data for long haul color displays to be generated, may display long haul color displays, and/or may enable archiving of data at user-selectable altitudes over a long observation period for data distribution and population.