WorldWideScience

Sample records for donor screening tests

  1. Unconfirmed reactive screening tests and their impact on donor management

    International Nuclear Information System (INIS)

    Rahman, M.; Khan, S.A.

    2008-01-01

    To determine the percentage of false positive testing for transfusion transmitted infections (TTIs) using immunochromatographic test (ICT) as first line of screening tests and its effect on loss of volunteer blood donors. Over a period of three months, samples from blood bags of donors undergoing phlebotomy at teaching hospital blood banks in Lahore were screened for human immunodeficiency virus (HIV), hepatitis B (HBV) and hepatitis C (HCV) by immunochromatographic tests. Those found positive on initial screening were re-tested by ELISA method at the screening laboratory of the Institute of Haematology and Blood Transfusion Service, Punjab. Lahore. Out of a total of 62090 voluntary blood donors, 469 donors were found to be initially reactive for either HIV, HBV or HCV. Amongst these 96 (0.15%) blood donors were found to have tested falsely positive for HIV, HBV or HCV as compared to testing by ELISA. False positive testing rate of 0.15% or 96 out of a total of 62090 donors is rather small in terms of loss of voluntary donors and appropriate utilization of available resources. Although immunochromatographic testing is not the gold standard, however it serves an important purpose of initial donor screening. (author)

  2. Transmission of Hepatitis C Virus From Organ Donors Despite Nucleic Acid Test Screening.

    Science.gov (United States)

    Suryaprasad, A; Basavaraju, S V; Hocevar, S N; Theodoropoulos, N; Zuckerman, R A; Hayden, T; Forbi, J C; Pegues, D; Levine, M; Martin, S I; Kuehnert, M J; Blumberg, E A

    2015-07-01

    Nucleic acid testing (NAT) for hepatitis C virus (HCV) is recommended for screening of organ donors, yet not all donor infections may be detected. We describe three US clusters of HCV transmission from donors at increased risk for HCV infection. Donor's and recipients' medical records were reviewed. Newly infected recipients were interviewed. Donor-derived HCV infection was considered when infection was newly detected after transplantation in recipients of organs from increased risk donors. Stored donor sera and tissue samples were tested for HCV RNA with high-sensitivity quantitative PCR. Posttransplant and pretransplant recipient sera were tested for HCV RNA. Quasispecies analysis of hypervariable region-1 was used to establish genetic relatedness of recipient HCV variants. Each donor had evidence of injection drug use preceding death. Of 12 recipients, 8 were HCV-infected-6 were newly diagnosed posttransplant. HCV RNA was retrospectively detected in stored samples from donor immunologic tissue collected at organ procurement. Phylogenetic analysis showed two clusters of closely related HCV variants from recipients. These investigations identified the first known HCV transmissions from increased risk organ donors with negative NAT screening, indicating very recent donor infection. Recipient informed consent and posttransplant screening for blood-borne pathogens are essential when considering increased risk donors. © Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.

  3. [Costs of Chagas' disease screening test in blood donors in two Colombian blood banks, 2015].

    Science.gov (United States)

    Alvis, Nelson José; Díaz, Diana Patricia; Castillo, Liliana; Alvis, Nelson Rafael; Bermúdez, María Isabel; Berrío, Olga Maritza; Beltrán, Mauricio; Castañeda-Orjuela, Carlos Andrés

    2018-03-15

    Transfusion is a mechanism of transmission of Chagas' disease. There are no studies on the costs of the screening test in Colombian blood banks. To estimate the costs of the screening test for Chagas' disease among blood donors in two Colombian blood banks, 2015. We conducted a micro-costing study from the perspective of the health care provider to estimate the cost of Chagas' disease testing in two blood banks, Banco de Sangre de la Cruz Roja, Seccional Bolívar, and Banco de Sangre del Hospital de Yopal, Casanare, taking into account four cost categories: 1) Administrative costs: public services and insurance costs were calculated based on the blood bank area in square meters; 2) capital costs: building and equipment costs that were annualized using a 3% discount rate and a lifespan of 20 years for building and five for equipment; 3) costs of Chagas' disease test materials and reagents adjusted by blood bank production level, and 4) costs of staff in charge of Chagas' disease test processing. The costs of transfusion bagsand immunohematology tests are also reported. The cost of Chagas' disease test in the blood bank of Seccional Bolívar was COP$ 37,804 (USD$ 12), and the blood bag and immunohematology test costs were COP$ 25,941 (USD$ 8.2) and COP$ 6,800 (USD$ 2.2), respectively. In the blood bank of Yopal, Casanare, the costs were COP$ 77,384 (USD$ 24.6), COP$ 30,141 (USD$ 9.6) and COP$ 12,627 (USD$ 4), respectively. Personnel cost accounted for the highest percentage of the total cost for both blood banks (47.5% in Seccional Bolívar, and 55.7% in Yopal, Casanare). Our results are an important input for the planning of services and cost-effectiveness studies for screening tests for Chagas' disease in Colombian blood banks.

  4. Polymerase chain reaction and blood culture in blood donors screened by ELISA test for Chagas' disease

    Directory of Open Access Journals (Sweden)

    Andréa Tieko Kinoshita-Yanaga

    2011-03-01

    Full Text Available The objective of this study was to evaluate, through blood culture and PCR, the results of the ELISA for Chagas' disease in the screening of blood donors in the public blood-supply network of the state of Paraná, Brazil, and to map the epidemiological profile of the donors with respect to their risk of infection by Trypanosoma cruzi. The negative and positive results of the ELISA were confirmed by blood culture and PCR for 190/191 individuals (99.5%. For one individual (0.5%, the ELISA was inconclusive, blood culture and IIF were negative, and IHA and PCR positive. Three individuals (1.6% were positive for T. cruzi on all the tests. Donors were predominantly female, and natives of Paraná, of rural origin, had observed or been informed of the presence of the vector in the municipalities where they resided, had never received a blood transfusion, had donated blood 1 to 4 times, and reported no cases of Chagas' disease in their families. We concluded that PCR and blood culturing have excellent potential for confirming the results of the ELISA, and that candidate blood donors with negative or positive tests have a similar risk of infection by T. cruzi, indicating that the ELISA test is sufficiently safe for screening blood prior to use.O objetivo deste estudo foi avaliar, pela hemocultura e PCR, os resultados do teste ELISA utilizado para doença de Chagas na triagem de doadores de sangue na rede pública do Estado do Paraná, Brasil, e traçar o perfil epidemiológico dos doadores quanto ao risco de infecção pelo Trypanosoma cruzi. Os resultados negativos e positivos do ELISA foram confirmados pela hemocultura e PCR em 190/191 indivíduos (99,5%. Para um indivíduo (0,5%, o teste de ELISA foi inconclusivo, hemocultura e IFI foram negativas, HAI e PCR foram positivas. Três indivíduos (1,6% foram positivos para T. cruzi em todos os testes. A maioria dos doadores era do sexo feminino, oriundos do Estado do Paraná, de origem rural, tinham

  5. Detection and identification of occult HBV in blood donors in Taiwan using a commercial, multiplex, multi-dye nucleic acid amplification technology screening test.

    Science.gov (United States)

    Lin, K T; Chang, C L; Tsai, M H; Lin, K S; Saldanha, J; Hung, C M

    2014-02-01

    The ability of a new generation commercial, multiplex, multi-dye test from Roche, the cobas TaqScreen MPX test, version 2.0, to detect and identify occult HBV infections was evaluated using routine donor samples from Kaohsiung Blood Bank, Taiwan. A total of 5973 samples were tested by nucleic acid amplification technology (NAT); 5898 in pools of six, 66 in pools of less than six and nine samples individually. NAT-reactive samples were retested with alternative NAT tests, and follow-up samples from the donors were tested individually by NAT and for all the HBV serological markers. Eight NAT-only-reactive donors were identified, and follow-up samples were obtained from six of the donors. The results indicated that all eight donors had an occult HBV infection with viral loads <12 IU/ml. The cobas(®) TaqScreen MPX test, version 2.0, has an advantage over the current Roche blood screening test, the cobas TaqScreen MPX test, for screening donations in countries with a high prevalence of occult HBV infections since the uncertainty associated with identifying samples with very low viremia is removed by the ability of the test to identify the viral target in samples that are reactive with the cobas TaqScreen MPX test, version 2.0. © 2013 International Society of Blood Transfusion.

  6. Improving the screening of blood donors with syphilis rapid diagnostic test (RDT) and rapid plasma reagin (RPR) in low- and middle-income countries (LMIC).

    Science.gov (United States)

    Sarkodie, F; Hassall, O; Owusu-Dabo, E; Owusu-Ofori, S; Bates, I; Bygbjerg, I C; Owusu-Ofori, A; Harritshøj, L H; Ullum, H

    2017-02-01

    Syphilis testing conventionally relies on a combination of non-treponemal and treponemal tests. The primary objective of this study was to describe the positive predictive value (PPV) of a screening algorithm in a combination of a treponemal rapid diagnostic test (RDT) and rapid plasma reagin (RPR) test at Komfo Anokye Teaching Hospital (KATH), Ghana. From February 2014 to January 2015, 5 mL of venous blood samples were taken from 16 016 blood donors and tested with a treponemal RDT; 5 mL of venous blood was taken from 526 consenting initial syphilis sero-reactive blood donors. These RDT reactive samples were confirmed with an algorithm, applying the Vitros ® /Abbott-Architect ® algorithm as gold standard. A total of 478 of 526 RDT reactive donors were confirmed positive for syphilis, making a PPV of 90·9%. Of the 172 (32·7%) donors who were also RPR positive, 167 were confirmed, resulting in a PPV of 97·1%. The PPV of the combined RDT and RPR (suspected active syphilis) testing algorithm was highest among donors at an enhanced risk of syphilis, family/replacement donors (99·9%), and among voluntary donors above 25 years (98·6%). Screening of blood donors by combining syphilis RDT and RPR with relatively good PPV may provide a reasonable technology for LMIC that has a limited capacity for testing and can contribute to the improvement of blood safety with a minimal loss of donors. © 2016 British Blood Transfusion Society.

  7. Optimal screening and donor management in a public stool bank.

    Science.gov (United States)

    Kazerouni, Abbas; Burgess, James; Burns, Laura J; Wein, Lawrence M

    2015-12-17

    Fecal microbiota transplantation is an effective treatment for recurrent Clostridium difficile infection and is being investigated as a treatment for other microbiota-associated diseases. To facilitate these activities, an international public stool bank has been created, which screens donors and processes stools in a standardized manner. The goal of this research is to use mathematical modeling and analysis to optimize screening and donor management at the stool bank. Compared to the current policy of screening active donors every 60 days before releasing their quarantined stools for sale, costs can be reduced by 10.3 % by increasing the screening frequency to every 36 days. In addition, the stool production rate varies widely across donors, and using donor-specific screening, where higher producers are screened more frequently, also reduces costs, as does introducing an interim (i.e., between consecutive regular tests) stool test for just rotavirus and C. difficile. We also derive a donor release (i.e., into the system) policy that allows the supply to approximately match an exponentially increasing deterministic demand. More frequent screening, interim screening for rotavirus and C. difficile, and donor-specific screening, where higher stool producers are screened more frequently, are all cost-reducing measures. If screening costs decrease in the future (e.g., as a result of bringing screening in house), a bottleneck for implementing some of these recommendations may be the reluctance of donors to undergo serum screening more frequently than monthly.

  8. Babesia microti real-time polymerase chain reaction testing of Connecticut blood donors: potential implications for screening algorithms.

    Science.gov (United States)

    Johnson, Stephanie T; Van Tassell, Eric R; Tonnetti, Laura; Cable, Ritchard G; Berardi, Victor P; Leiby, David A

    2013-11-01

    Babesia microti, an intraerythrocytic parasite, has been implicated in transfusion transmission. B. microti seroprevalence in Connecticut (CT) blood donors is approximately 1%; however, it is not known what percentage of donors is parasitemic and poses a risk for transmitting infection. Therefore, we determined the prevalence of demonstrable B. microti DNA in donors from a highly endemic area of CT and compared observed rates with concurrent immunofluorescence assay (IFA) testing results. Blood samples from consenting donors in southeastern CT were collected from mid-August through early October 2009 and tested by IFA for immunoglobulin G antibodies and real-time polymerase chain reaction (PCR) for B. microti DNA. IFA specificity was determined using blood donor samples collected in northwestern Vermont (VT), an area nonendemic for Babesia. Of 1002 CT donors, 25 (2.5%) were IFA positive and three (0.3%) were real-time PCR positive. Among the three real-time PCR-positive donors, two were also IFA positive, while one was IFA negative and may represent a window period infection. The two IFA- and real-time PCR-positive donors appeared to subsequently clear infection. The other real-time PCR-positive donor did not provide follow-up samples. Of 1015 VT donors tested by IFA, only one (0.1%) was positive, but may have acquired infection during travel to an endemic area. We prospectively identified several real-time PCR-positive blood donors, including an IFA-negative real-time PCR-positive donor, in an area highly endemic for B. microti. These results suggest the need to include nucleic acid testing in planned mitigation strategies for B. microti. © 2013 American Association of Blood Banks.

  9. High-throughput strategy for molecular identification of Vel- blood donors employing nucleic acids extracted from plasma pools used for viral nucleic acid test screening.

    Science.gov (United States)

    Dezan, Marcia R; Dinardo, Carla L; Bosi, Silvia R A; Vega, Sileni; Salles, Nanci A; Mendrone-Júnior, Alfredo; Levi, José E

    2016-06-01

    Serologic methods to determine the Vel- phenotype require the use of rare human antisera and do not allow for many samples to be tested simultaneously, which limits their application as a tool to search for rare donors. This study developed a low-cost molecular screening strategy using real-time polymerase chain reaction (PCR) and DNA, extracted from plasma pools for viral nucleic acid test (NAT) screening, to identify Vel- and Vel+(W) donors. A total of 4680 blood donors from the Brazilian southeast region were genotyped through real-time PCR targeting the 17-nucleotide (c.64_80del) deletion in the SMIM1 gene, which determines the Vel- phenotype, by using remaining nucleic acid from plasma pools of six donors, routinely discarded after the release of viral NAT results. Twenty pools tested reactive and individual testing of samples from reactive pools identified 19 heterozygous donors with the SMIM1*64_80del deletion (0.40%) and one homozygous donor (0.02%). Fourteen of the 19 donors were confirmed as Vel- or Vel+(W) using anti-Vel human antiserum. The DNA pool genotyping strategy using real-time PCR designed to detect the deletion in the SMIM1 gene proved effective and accurate in identifying donors with the Vel- and Vel+(W) phenotypes. The fact that remaining nucleic acid from routine viral NAT screening was used makes this technique economically attractive and definitely superior to the serologic techniques available to search for this rare phenotype. © 2016 AABB.

  10. Prevalence of HIV positive blood donors among screened ...

    African Journals Online (AJOL)

    hope&shola

    2006-04-03

    Apr 3, 2006 ... Department of Physiology, Obafemi Awolowo College of Health Sciences, Olabisi Onabanjo University Teaching. Hospital ... screening volunteer donors by initial criteria alone does not fully eliminate all HIV positive donors. The prevalence of HIV ... HIV test criteria alone to qualify for blood donation in the.

  11. Prevalence of human immunodeficiency virus type 1 p24 antigen in U.S. blood donors--an assessment of the efficacy of testing in donor screening. The HIV-Antigen Study Group.

    Science.gov (United States)

    Alter, H J; Epstein, J S; Swenson, S G; VanRaden, M J; Ward, J W; Kaslow, R A; Menitove, J E; Klein, H G; Sandler, S G; Sayers, M H

    1990-11-08

    We performed a multicenter study in 1989 to determine whether screening whole-blood donors for human immunodeficiency virus type 1 (HIV-1) p24 antigen would improve transfusion safety by identifying carriers of the virus who are seronegative for HIV-1 antibody. More than 500,000 donations were tested at 13 U.S. blood centers with test kits from two manufacturers. Units found repeatedly reactive were retested in a central laboratory; if the results were positive, they were confirmed by a neutralization assay. A subgroup of units was also tested for HIV-1 by the polymerase chain reaction. Selected donors confirmed or not confirmed as having p24 antigen were contacted for follow-up interviews to identify risk factors and undergo retesting for HIV-1 markers. Positive tests for p24 antigen were confirmed by neutralization in five donors (0.001 percent of all donations tested), all of whom were also positive for HIV-1 antibody and HIV-1 by polymerase chain reaction. Three of the antigen-positive donors had other markers of infectious disease that would have resulted in the exclusion of their blood; two had risk factors for HIV-1 that should have led to self-exclusion. Of 220 blood units with repeatedly reactive p24 antigen whose presence could not be confirmed by neutralization (0.04 percent of the donations studied), none were positive for HIV-1 antibody, HIV-1 by polymerase chain reaction (120 units tested), or virus culture (76 units tested)--attesting to the specificity of confirmatory neutralization. The finding that no donation studied was positive for p24 antigen and negative for HIV-1 antibody suggests that screening donors for p24 antigen with tests of the current level of sensitivity would not add substantially to the safety of the U.S. blood supply.

  12. One window-period donation in two years of individual donor-nucleic acid test screening for hepatitis B, hepatitis C and human immunodeficiency virus

    Directory of Open Access Journals (Sweden)

    Jose Eduardo Levi

    2013-06-01

    Full Text Available Objective: To describe general data on nucleic acid/serology testing and report the first hepatitis B-nucleic acid testing yield case of an immunized donor in Brazil. Methods: A total of 24,441 donations collected in 2010 and 2011 were submitted to individual nucleic acid testing for hepatitis B, hepatitis C and human immunodeficiency virus using the TaqMan® MPX kit (Roche on the Cobas s201 platform, in addition to routine screening for serological markers. Nucleic acid testing-reactive donations were further evaluated by real-time polymerase chain reaction using Cobas AmpliPrep/Cobas TaqMan hepatitis B virus, hepatitis C virus and human immunodeficiency virus tests. Results: Thirty-two donations were reactive by nucleic acid testing, 31 were also serologically reactive and one first-time donor was identified as having hepatitis B in the window period. Follow-up samples showed increasing titers of anti-HBs rising from 19 UI/mL in the index donation to 109 IU/mL seven months later attributable to his vaccination history. Curiously, this donor was never reactive for HbsAg nor for anti-HBc. In the yield donation, he was concomitantly reactive for syphilis (enzyme immunoassay and fluorescent treponemal antibody-absorption; venereal disease research laboratory non-reactive. Overall, six donors (0.02% were characterized as occult hepatitis B. A total of 35% of the confirmed (recombinant immunoblot assay positive hepatitis C donations were nucleic acid testing non-reactive and no human immunodeficiency virus "elite controller" was identified. Conclusion: The yield rate (1:24,441; 95% confidence interval: 1:9,537 - 1:89,717 contrasts to the North American rate (1:410,540 donations and strongly advocates the adoption of nucleic acid testing for hepatitis B in Brazil despite the increasing rate of anti-HBs reactive subjects due to the successful immunization program.

  13. ESHRE Task Force on Ethics and Law 21: genetic screening of gamete donors: ethical issues.

    Science.gov (United States)

    Dondorp, W; De Wert, G; Pennings, G; Shenfield, F; Devroey, P; Tarlatzis, B; Barri, P; Diedrich, K; Eichenlaub-Ritter, U; Tüttelmann, F; Provoost, V

    2014-07-01

    This Task Force document explores the ethical issues involved in the debate about the scope of genetic screening of gamete donors. Calls for expanded donor screening arise against the background of both occasional findings of serious but rare genetic conditions in donors or donor offspring that were not detected through present screening procedures and the advent of new genomic technologies promising affordable testing of donors for a wide range of conditions. Ethical principles require that all stakeholders' interests are taken into account, including those of candidate donors. The message of the profession should be that avoiding all risks is impossible and that testing should remain proportional.

  14. Establishment of an oocyte donor program. Donor screening and selection.

    Science.gov (United States)

    Quigley, M M; Collins, R L; Schover, L R

    1991-01-01

    IVF with donated oocytes, followed by embryo placement in the uterus of a recipient who has been primed with exogenous steroids, is a successful treatment for special cases of infertility. Preliminary results indicate that the success rate in this situation is even greater than that usually seen with normal IVF (with placement of the embryos back into the uteri of the women from whom the oocytes were recovered). Although different sources for donated oocytes have been identified, the use of "excess" oocytes from IVF cycles and the attempted collection of oocytes at the time of otherwise indicated pelvic surgery have ethical and practical problems associated with their use. We have herein described the establishment of a successful program relying on anonymous volunteers who go through ovarian stimulation, monitoring, and oocyte recovery procedures solely to donate oocytes. The potential donors go through an exhaustive screening and education process before they are accepted in the program. Psychological evaluation of our potential donors indicated a great degree of turmoil in their backgrounds and a wide variety of motivations for actually participating. Despite the extensive educational and screening process, a substantial percentage of the donors did not complete a donation cycle, having either voluntarily withdrawn or been dropped because of lack of compliance. Further investigation of the psychological aspects of participating in such a program is certainly warranted. The use of donated oocytes to alleviate specific types of infertility is quite successful, but the application of this treatment is likely to be limited by the relative unavailability of suitable oocyte donors.

  15. Blood donors screening for malaria in non-endemic area in the Kingdom of Saudi Arabia: Is it necessary to introduce immunological testing?

    Science.gov (United States)

    Elyamany, Ghaleb; Al Gharawi, Ali; Alrasheed, Mohammed; Alsuhaibani, Omar

    2016-02-01

    In Saudi Arabia, where malaria is not endemic, the incidence is very low. However, malaria transmission cases have been reported, mainly in Asir and Jazan provinces along the Southwestern border with Yemen. Imported cases also have been reported. The aims of this study were to determine the prevalence of malaria in blood donors in a tertiary care hospital in the central area of Saudi Arabia and to assess the effectiveness of malaria screening methods used by transfusion services in Prince Sultan Military Medical City. This study was conducted on 180,000 people who donated blood during 2006-2015. All blood smears from blood donors were screened for malaria infection using Giemsa staining, low power and high power microscopic examinations, and using oil immersion lens. The data were analyzed and reported in descriptive statistics and prevalence. From the total of 180,000 blood donors who were screened for malaria, 156,000 (87%) and 23.400 (13%) were Saudi Arabia citizens and non-Saudi residents, respectively. The mean age of the blood donors was 32 (ranging from 18 to 65), 97% and 3% were male and female, respectively. Using our current method for malaria screening, the prevalence of malaria in the study population was zero. The current methods of malaria screening in blood donors is not suitable for screening low-level parasiotemia. Adding the immunoassay and molecular screening methods is suggested.

  16. Predonation screening of candidate donors and prevention of window period donations.

    Science.gov (United States)

    Lieshout-Krikke, Ryanne W; Zaaijer, Hans L; van de Laar, Thijs J W

    2015-02-01

    Infectious window period donations slip through routine donor screening procedures. To explore the potential value of predonation screening of candidate donors, we compared the proportion of incident transfusion-transmissible infections in candidate donors, in first-time donors, and in repeat donors. A retrospective analysis was performed of all incident hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV) infections in candidate, first-time, and repeat donors in the Netherlands during the period 2009 to 2013. In total, 176,716 candidate donors, 144,226 first-time donations, and 4,143,455 repeat donations were screened for HBV, HCV, and HIV infection. Acute HBV infection was identified in the predonation sample of six candidate donors. One first-time donor, testing HIV-negative at predonation screening, tested positive for anti-HIV and HIV RNA in the first donation 29 days later. Among repeat donations we identified 15, one, and six incident HBV, HCV and HIV infections, respectively. The proportion of incident infections among candidate donors/first-time donations/repeat donations was for HBV, 3.40/0/0.36; for HCV, 0/0/0.02; and for HIV 0/0.69/0.14 per 100,000, respectively. Predonation screening of candidate donors very likely causes a loss of donations, but it might prevent undetected window period donations. Further studies are necessary to determine the value of predonation screening as an additional safety measure. © 2014 AABB.

  17. Performance of six diagnostic tests to screen for Chagas disease in blood banks andprevalence of Trypanosoma cruzi infection among donors with inconclusive serologyscreening based on the analysis of epidemiological variables.

    Science.gov (United States)

    Pereira, Gilberto de Araujo; Louzada-Neto, Francisco; Barbosa, Valdirene de Fátima; Ferreira-Silva, Márcia Maria; de Moraes-Souza, Helio

    2012-01-01

    The frequent occurrence of inconclusive serology in blood banks and the absence of a gold standard test for Chagas'disease led us to examine the efficacy of the blood culture test and five commercial tests (ELISA, IIF, HAI, c-ELISA, rec-ELISA) used in screening blood donors for Chagas disease, as well as to investigate the prevalence of Trypanosoma cruzi infection among donors with inconclusive serology screening in respect to some epidemiological variables. To obtain estimates of interest we considered a Bayesian latent class model with inclusion of covariates from the logit link. A better performance was observed with some categories of epidemiological variables. In addition, all pairs of tests (excluding the blood culture test) presented as good alternatives for both screening (sensitivity > 99.96% in parallel testing) and for confirmation (specificity > 99.93% in serial testing) of Chagas disease. The prevalence of 13.30% observed in the stratum of donors with inconclusive serology, means that probably most of these are non-reactive serology. In addition, depending on the level of specific epidemiological variables, the absence of infection can be predicted with a probability of 100% in this group from the pairs of tests using parallel testing. The epidemiological variables can lead to improved test results and thus assist in the clarification of inconclusive serology screening results. Moreover, all combinations of pairs using the five commercial tests are good alternatives to confirm results.

  18. Serum neopterin: a potential marker for screening blood donors

    International Nuclear Information System (INIS)

    Ashfaq, A.; Ejaz, A.; Abbas, G.

    2017-01-01

    To determine serum neopterin levels in blood donors of local population and its association with transfusion ransmitted infections. Study Design: A cross-sectional observational study. Place and Duration of Study:Department of Physiology, Liaquat National Hospital and Medical College (LNHMC) in collaboration with Basic Medical Sciences Institute (BMSI) and Jinnah Postgraduate Medical Centre (JPMC), Blood Bank, Karachi, Pakistan, from January to June 2015. Methodology: During this period, a total of 174 blood donors were selected through random sampling technique. All participants fulfilling the inclusion criteria involving apparently healthy blood donors of either gender within the age bracket of 18 - 60 years and consenting to participate were selected. The participants were screened for transfusion transmitted infections as per WHO recommendations through the standard procedures used for screening at the JPMC blood bank. The demographic profile, anthropometric measurements and vitals were recorded for every participant. Serum neopterin was measured using ELISA kits. Data was analysed on SPSS version 21. ANOVA and chi-square tests were applied as tests of significance at a p-value of <0.05. Results: The neopterin content in the sera of disease negative blood donors was 6.23 +-2.19 nmol/l as compared to disease positive blood donors, in whom the neopterin level was increased to 15.10 +-4.93 nmol/l (p =0.001). Conclusion: The neopterin assay has the potential to detect a number of transfusion transmissible viral diseases; which may, or may not be revealed by the usually employed battery of routine tests. We conclude that the risk of transfusion transmitted pathogens in our population can be reduced significantly, using neopterin assay as a routine in blood banks. (author)

  19. Prevalence of HIV positive blood donors among screened ...

    African Journals Online (AJOL)

    Two thousand five hundred and thirty two (2,532) males, aged 25 – 50 years potential blood donors were randomly selected from the total number of volunteer blood donors who satisfied the initial screening criteria for donating blood, and were screened for HIV using Immunocomb II (HIV 1 and 2 Bispot) and Recombigen ...

  20. A novel strategy for screening blood donors for syphilis at Komfo Anokye Teaching Hospital, Ghana

    DEFF Research Database (Denmark)

    Sarkodie, F; Ullum, H; Owusu-Dabo, E

    2016-01-01

    OBJECTIVE: To implement and describe a novel syphilis screening strategy for blood donors. BACKGROUND: The seroprevalence of syphilis in blood donors is often high in low- and middle-income countries (LMIC) although the proportion of infectious donations is probably low. Syphilis screening may...... not happen at all; or the use of non-specific screening tests, which have high false positive rates, results in many donations being discarded unnecessarily. This can have a critical effect on already inadequate blood supplies. MATERIALS AND METHODS: Blood donors were screened at the time of donation...... negative were released to stock and test-positive units discarded. RESULTS: Of the 2213 blood donors, 182 (8·2%; 182/2213) screened positive by RDT. In addition, 38 out of these 182 (20·9%) were RPR positive on post-donation testing. Over 2 months there was a 79% reduction in blood units discarded due...

  1. Donor's understanding of the definition of sex as applied to predonation screening questions.

    Science.gov (United States)

    O'Brien, S F; Ram, S S; Yi, Q-L; Goldman, M

    2008-05-01

    Predonation screening questions about sexual risk factors should provide an extra layer of safety from recently acquired infections that may be too early to be detected by testing. Donors are required to read a definition of sex as it applies to predonation screening questions each time they come to donate, but how well donors apply such definitions has not been evaluated. We aimed to determine how donors define sex when answering screening questions. In total, 1297 whole blood donors were asked in a private interview to select from a list of sexual activities which ones they believed were being asked about in sexual background questions. Donors' definitions were coded as under-inclusive, correct or over-inclusive in relation to the blood services' definition. Qualitative interviews were carried out with 21 donors to understand reasoning behind definitions. Most donors had an over-inclusive definition (58.7%) or the correct definition (31.9%). Of the 9.4% of donors who had an under-inclusive definition, 95% included both vaginal and anal sex, but not oral sex. About 9% in each group were first-time donors (P > 0.05) who had never read the definition. The qualitative interviews indicated that donors reason their definition based on their own concept of transmissible disease risk. Donors apply a range of definitions of sex when answering questions about their sexual background. This may be due to different concepts of risk activities, and required reading of the definition has little impact.

  2. Chagas' disease: an algorithm for donor screening and positive donor counseling

    Directory of Open Access Journals (Sweden)

    Nelson Hamerschlak

    1997-06-01

    Full Text Available Classical serological screening assays for Chagas' disease are time consuming and subjective. The objective of the present work is to evaluate the enzyme immuno-assay (ELISA methodology and to propose an algorithm for blood banks to be applied to Chagas' disease. Seven thousand, nine hundred and ninety nine blood donor samples were screened by both reverse passive hemagglutination (RPHA and indirect immunofluorescence assay (IFA. Samples reactive on RPHA and/or IFA were submitted to supplementary RPHA, IFA and complement fixation (CFA tests. This strategy allowed us to create a panel of 60 samples to evaluate the ELISA methodology from 3 different manufacturers. The sensitivity of the screening by IFA and the 3 different ELISA's was 100%. The specificity was better on ELISA methodology. For Chagas disease, ELISA seems to be the best test for blood donor screening, because it showed high sensitivity and specificity, it is not subjective and can be automated. Therefore, it was possible to propose an algorithm to screen samples and confirm donor results at the blood bank.Os testes sorológicos clássicos utilizados na triagem de doadores de sangue são trabalhosos e subjetivos. O objetivo do presente trabalho é o de avaliar a metodologia imuno-enzimática (ELISA e propor um algorítmo para doença de Chagas em bancos de sangue. Foram estudados 7999 doadores de sangue e/ou componentes cujas amostras foram testadas com o objetivo de tria-las sorologicamente para doença de Chagas utilizando hemaglutinação passiva reversa (RPHA e imunofluorescência indireta (IFA. As amostras reativas em pelo menos uma destas metodologias, foram retestadas com reativos diferentes por RPHA, IFA e fixação de complemento (CFA. Esta estratégia nos permitiu criar um painel de 60 amostras com as quais tornou-se possível a avaliação do método imunoenzimático (ELISA. A sensibilidade da triagem dos doadores pelos métodos ELISA e IFA foi de 100%. A especificidade

  3. Improving the screening of blood donors with syphilis rapid diagnostic test (RDT) and rapid plasma reagin (RPR) in low- and middle-income countries (LMIC)

    DEFF Research Database (Denmark)

    Sarkodie, F.; Hassall, O.; Owusu-Dabo, E.

    2017-01-01

    BACKGROUND: Syphilis testing conventionally relies on a combination of non-treponemal and treponemal tests. The primary objective of this study was to describe the positive predictive value (PPV) of a screening algorithm in a combination of a treponemal rapid diagnostic test (RDT) and rapid plasma...

  4. Testing UK blood donors for exposure to human parvovirus 4 using a time-resolved fluorescence immunoassay to screen sera and Western blot to confirm reactive samples.

    Science.gov (United States)

    Maple, Peter A C; Beard, Stuart; Parry, Ruth P; Brown, Kevin E

    2013-10-01

    Human parvovirus 4 (ParV4), a newly described member of the family Parvoviridae, like B19V, has been found in pooled plasma preparations. The extent, and significance, of ParV4 exposure in UK blood donors remain to be determined and reliable detection of ParV4 immunoglobulin (Ig)G, using validated methods, is needed. With ParV4 virus-like particles a ParV4 IgG time-resolved fluorescence immunoassay (TRFIA) was developed. There is no gold standard or reference assay for measuring ParV4 IgG and the utility of the TRFIA was first examined using a panel of sera from people who inject drugs (PWIDS)--a high-prevalence population for ParV4 infection. Western blotting was used to confirm the specificity of TRFIA-reactive sera. Two cohorts of UK blood donor sera comprising 452 sera collected in 1999 and 156 sera collected in 2009 were tested for ParV4 IgG. Additional testing for B19V IgG, hepatitis C virus antibodies (anti-HCV), and ParV4 DNA was also undertaken. The rate of ParV4 IgG seroprevalence in PWIDS was 20.7% and ParV4 IgG was positively associated with the presence of anti-HCV with 68.4% ParV4 IgG-positive sera testing anti-HCV-positive versus 17.1% ParV4 IgG-negative sera. Overall seropositivity for ParV4 IgG, in 608 UK blood donors was 4.76%. The ParV4 IgG seropositivity for sera collected in 1999 was 5.08%, compared to 3.84% for sera collected in 2009. No ParV4 IgG-positive blood donor sera had detectable ParV4 DNA. ParV4 IgG has been found in UK blood donors and this finding needs further investigation. © 2013 American Association of Blood Banks.

  5. Seroprevalence of human T-cell lymphotropic virus-1/2 in blood donors in northern pakistan: implication for blood donor screening

    International Nuclear Information System (INIS)

    Niazi, S.K.

    2015-01-01

    To determine the seroprevalence of Human T-cell Lymphotropic Virus-1/2 (HTLV-1/2) in blood donors in Northern Pakistan. Study Design: Descriptive study. Place and Duration of Study: Armed Forces Institute of Transfusion, Rawalpindi, from July to August 2013. Methodology:A total of 2100 blood donors were screened for anti-HTLV-1/2 antibodies during the study period, in a pool of six, on a highly sensitive, Chemiluminiscent Microparticle Immunoassay (CMIA) based system. The screening test reactive donors were recalled, counseled and interviewed, and a fresh sample was obtained for confirmatory testing. Confirmation was performed using additional immunoassays including Line Immunoassay (LIA); with additional testing for HTLV-1 pvDNAPCR. Frequency and percentages were determined. Results: Four donors (0.19%) were repeatedly screening test-reactive and were subsequently confirmed to be HTLV-1 infected by line immunoassay and HTLV-1 pvDNAPCR. All four donors were male with mean age of 27 ± 6.27 years. Two (50%) of the positive donors gave history of Multiple Sexual Partners (MSP). Conclusion: HTLV-1 seroprevalence in Northern Pakistan blood donors was determined to be 0.19%. Large scale studies, including the cost effectiveness of screening blood donations for anti-HTLV-1/2 in Pakistan, are recommended. (author)

  6. Transfusion transmitted virus in screened United Arab Emirates blood donors

    International Nuclear Information System (INIS)

    Alfaresi, Mubarak S.; Alzaabi, Azza S.; Islam, Adeel A.; Elkoush, Abida A.; Elnazer, Ayat M.

    2006-01-01

    To investigate the rate of infection caused by Torque teno virus (TTV) in United Arab Emirates (UAEs) healthy population as a pilot study in detecting TTV DNA in 100 healthy blood donors. We randomly choose a total of 100 healthy blood donors who attended Zayed Military Hospital, Abu Dhabi, UAE from January 20 to May 30, 2005. We carried out a real-time polymerase chain reaction (PCR) test to detect TTV DNA. Real-time for TTV was positive in 75 (75%) donors. Eight (73%) non-UAE donors were TTV positive while 67 (75%) were UAEs. Among these donors, 72 (77%) were males and 3 (50%) were females. Our results demonstrated a high prevalence of TTV in UAE. (author)

  7. Cost and effectiveness comparison of two methods for screening potential blood donors for anaemia in Vietnam.

    Science.gov (United States)

    Tyrrell, A; Worrall, E; Que, T N; Bates, I

    2011-06-01

    To compare the cost and effectiveness of Copper Sulphate (CS) and HemoCue (HC) methods for screening blood donors for anaemia. Robust information from developing countries about cost and effectiveness of anaemia screening methods for blood donors is scarce. In such countries there are widespread shortages of blood, so the most cost-effective method should maximise blood supply without compromising donor safety. Economic data (e.g. staff time, equipment and buildings) were collected from direct observation of procedures and purchase data from Hanoi's Central Blood Bank administrative department. A framework for comparing the cost and effectiveness of anaemia screening methods was developed and a cost per effective (i.e. usable and accurate) test was generated for each method. Samples from 100 potential donors from the Hanoi Central Blood Bank (static) and 198 from two mobile units were tested. The mean probability of an ineffective anaemia test was 0·1 (0·05-0·2). The average cost of an HC test was $0·75 (static $0·61 and mobile $0·89) and a CS test was $0·31 (static $0·17 and mobile $0·45). The difference between static and mobile units was predominantly due to transport costs; the difference between the two methods was predominantly due to the HC microcuvettes. In this setting the CS yields greater value for money than the HC method for screening blood donors. The relative cost and effectiveness of CS and HC may be different in places with higher staff turnover, lower test accuracy, higher anaemia prevalence or lower workload than in Vietnam. © 2010 Liverpool School of Tropical Medicine. Transfusion Medicine © 2010 British Blood Transfusion Society.

  8. ELISA with double antigen sandwich for screening specific serum anti-TP antibody in blood donors

    International Nuclear Information System (INIS)

    Wang Yiqing; Shi Zhixu

    2002-01-01

    Objective: To select a sensitive and specific laboratory examination suitable for screening serum anti-TP antibody in blood donors. Methods: The serum anti-TP antibody in 11271 blood donors were detected using ELISA with double antigen sandwich and the outcomes were compared with those using RPR assay. The conflicting specimen were confirmed by repeating the test with TPHA assay. Results: The positive rates of serum anti-TP antibody by ELISA with double antigen sandwich and RPR was 0.36% (41/11271) and 0.26% (29/11271), respectively. The coincidence of the detecting outcomes by ELISA with double antigen sandwich and RPR with TPHA was 97.5% (40/41) and 63.41%(26/41) respectively. Conclusion: Compared with RPR assay, ELISA with double antigen sandwich has higher sensibility and specificity for screening serum anti-TP antibody in blood donors

  9. Etiology of anemia of blood donor candidates deferred by hematologic screening

    Directory of Open Access Journals (Sweden)

    Michel Alves da Silva

    2012-01-01

    Full Text Available OBJECTIVE: Iron deficiency is the most common cause of anemia and one of the main factors in the clinical deferral of blood donors. This fact prompted the current study that aimed to determine the prevalence and etiology of anemia in blood donor candidates and to evaluate the hematological screening technique used for the exclusion of these donors. METHODS: This was a prospective study that compared two groups (Anemic and Non-anemic. Initially screening for anemia was performed by manually measuring hemoglobin (Bioclin® Kit; the results were subsequently compared with an automated screening method (Coulter T-890. The etiology was investigated by hemoglobin electrophoresis in alkaline and acid pH, Hb A2 dosage and measurement of the ferritin concentration by immunoagglutination. Differences and associations of interest were analyzed using the Yates and McNemar's Chi-square tests and the Fisher, Mann-Whitney, Wilcoxon and Kruskal-Wallis tests. RESULTS: The deferral rate due to anemia was 4.2%; iron deficiency was identified in 37.5% and beta thalassemia in 9.3% of the excluded candidates. There was a significant discrepancy between the two techniques used to measure hemoglobin with 38.1% of initially deferred donors presenting normal hemoglobin levels by the automated method. CONCLUSION: The results show a high rate of blood donors being deferred for anemia and confirm that iron deficiency is the most prevalent cause. The discrepancies found by comparing screening methods suggest that hemoglobin and hematocrit levels should be confirmed before deferring a donor due to anemia; this may increase supplies in blood banks.

  10. Nucleic acid amplification test for detection of west nile virus infection in pakistani blood donors

    International Nuclear Information System (INIS)

    Niazi, S.K.; Alam, M.

    2017-01-01

    Background: The study was planned to determine the presence of West Nile Virus (WNV) infection in Pakistani blood donors, using Nucleic Acid Amplification Test (NAT). Methods: The blood donors for study were selected on the basis of the standard questionnaire and routine screening results. Six donors were pooled using an automated pipettor and NAT for WNV was performed on Roche Cobas s 201 NAT system. The reactive pools were resolved in Individual Donation-NAT (ID-NAT) format and a sample from FFP bags of reactive donations was retrieved. NAT was again performed on retrieved plasma bag (RPB) sample to confirm the reactive donations. The donors were also recalled and interviewed about history of illness related to recent WNV infection. Results: After serological screening of 1929 donors during the study period, 1860 donors were selected for NAT test for WNV detection. The mean age of the donors was 28±8.77 (range: 18–57 years). 1847 (99.3%) donors were male and 13 (0.7%) were female. NAT for WNV identified six initially reactive pools (0.32%). On follow-up testing with RPB samples, 4 donors (0.21%) were found confirmed reactive for WNV RNA (NAT yield of 1 in 465 blood donors). Conclusion: WNV is a threat to safety of blood products in Pakistan. A screening strategy can be implemented after a large-scale study and financial considerations. One of the reduced cost screening strategies is seasonal screening of blood donors for WNV, with pooling of samples. (author)

  11. Experience of German Red Cross blood donor services with nucleic acid testing: results of screening more than 30 million blood donations for human immunodeficiency virus-1, hepatitis C virus, and hepatitis B virus.

    Science.gov (United States)

    Hourfar, Michael K; Jork, Christine; Schottstedt, Volkmar; Weber-Schehl, Marijke; Brixner, Veronika; Busch, Michael P; Geusendam, Geert; Gubbe, Knut; Mahnhardt, Christina; Mayr-Wohlfart, Uschi; Pichl, Lutz; Roth, W Kurt; Schmidt, Michael; Seifried, Erhard; Wright, David J

    2008-08-01

    The risk of transfusion-transmitted human immunodeficiency virus-1 (HIV-1), hepatitis C virus (HCV), and hepatitis B virus (HBV) infections is predominantly attributable to donations given during the early stage of infection when diagnostic tests may fail. In 1997, nucleic acid amplification technique (NAT)-testing was introduced at the German Red Cross (GRC) blood donor services to reduce this diagnostic window period (WP). A total of 31,524,571 blood donations collected from 1997 through 2005 were screened by minipool NAT, predominantly with pool sizes of 96 donations. These donations cover approximately 80 percent of all the blood collected in Germany during that period. Based on these data, the WP risk in the GRC blood donor population was estimated by using a state-of-the-art mathematic model. During the observation period, 23 HCV, 7 HIV-1, and 43 HBV NAT-only-positive donations were detected. On the basis of these data and estimated pre-NAT infectious WPs, the residual risk per unit transfused was estimated at 1 in 10.88 million for HCV (95% confidence interval [CI], 7.51-19.72 million), 1 in 4.30 million for HIV-1 (95% CI, 2.39-21.37 million), and 1 in 360,000 for HBV (95% CI, 0.19-3.36 million). Based on observed cases of breakthrough infections, the risk of transfusion-related infections may be even lower. The risk of a blood recipient becoming infected with HCV, HIV-1, or HBV has reached an extremely low level. Introduction of individual donation testing for HCV and HIV-1 would have a marginal effect on interception of WP donations.

  12. Strongyloidiasis in Po valley: serological and parasitological screening in blood donors of Cremona

    Directory of Open Access Journals (Sweden)

    Paolo Mangoni

    2012-09-01

    Full Text Available Backgroud. Strongyloides stercoralis is a ubiquitous nematode that is present also in Italy in a hypoendemic form, especially in the Po Valley. It is responsable for strongyloidiasis, an intestinal parasitosis usually asymptomatic or paucy-symptomatic that occasionally can cause a hyperinfestation syndrome and disseminated disease. Objectives. To determine the presence of S. stercoralis in asympomatic people afferent to the Cremona hospital by serological screening and direct microscopic search. Study Design. In the period from December 1, 2010 to June 30, 2011 we screened 154 donors with absolute eosinophilia >500/μL and percentage of eosinophils 9%. The research of anti-S. stercoralis antibodies was performed through an ELISA method (S.ratti Bordier Products. Donors positive to the screening test were tested for direct parasite search through with phormol-ethyl acetate stool concentration (FEA and culture on S. stercoralis Agar (Biolife, Milan. Results. 13 donors were positive to the screening test (8.4%. 10 of these 13 donors performed coproparassitologic examination. S. stercoralis was identified in the stools of 3/10 tested patients through culture and in 2/10 through FEA. Conclusions. The study results are in line with the data reported in the literature for similar geographic areas. Among the risk factors are to be counted the type of job (agriculture, and the domicile in the rural environment. The culture in S. stercoralis Agar has proved much more sensitive than FEA. The serological diagnosis represent a valuable contribution to traditional coproparassitologic examination, particularlywhen screening asymptomatic individuals at risk.

  13. Tattoos and transfusion-transmitted disease risk: implications for the screening of blood donors in Brazil

    Directory of Open Access Journals (Sweden)

    Sérgio de A. Nishioka

    Full Text Available Having a tattoo has been associated with serological evidence of hepatitis B and C viruses, as well as human immunodeficiency virus infections and syphilis; all of these are known to be transmissible by blood transfusion. These associations are of higher magnitude for individuals with nonprofessionally-applied tattoos and with two or more tattoos. Tattoos are common among drug addicts and prisoners, conditions that are also associated with transfusion-transmitted diseases. We examined the implications of these associations for the screening of blood donors in Brazil. Numbers of individuals who would be correctly or unnecessarily deferred from blood donation on the basis of the presence of tattoos, and on their number and type, were calculated for different prevalence situations based on published odds ratios. If having a tattoo was made a deferral criterion, cost savings (due to a reduced need for laboratory testing and subsequent follow-up would accrue at the expense of the deferral of appropriate donors. Restricting deferral to more `at-risk' sub-groups of tattooed individuals would correctly defer less individuals and would also reduce the numbers of potential donors unnecessarily deferred. Key factors in balancing cost savings and unnecessary deferrals include the magnitude of the pool of blood donors in the population, the prevalence of individuals with tattoos and the `culture' of tattoos in the population. Tattoos can therefore be an efficient criterion for the screening of blood donors in certain settings, a finding that requires corroboration from larger population-based studies.

  14. Glucose screening tests during pregnancy

    Science.gov (United States)

    Oral glucose tolerance test - pregnancy; OGTT - pregnancy; Glucose challenge test - pregnancy; Gestational diabetes - glucose screening ... screening test between 24 and 28 weeks of pregnancy. The test may be done earlier if you ...

  15. Neonatal cystic fibrosis screening test

    Science.gov (United States)

    Cystic fibrosis screening - neonatal; Immunoreactive trypsinogen; IRT test; CF - screening ... Cystic fibrosis is a disease passed down through families. CF causes thick, sticky mucus to build up in ...

  16. Follow up Evaluation of Air Force Blood Donors Screening Positive for Chagas Disease

    Science.gov (United States)

    2017-10-05

    59 MDW/SGVU SUBJECT: Professional Presentation Approval 31 JULY2017 Your paper, entitled Follow-up Evaluation of Air Force Blood Donors Screening...PUBLISHED OR PRESENTED: Follow-up Evaluation of Air Force Blood Donors Screening Positive for Chagas Disease 7. FUNDING RECEIVED FOR THIS STUDY? 0...PREVIOUS EDITIONS ARE OBSOLETE 50. DATE Page 3 of 3 Pages Follow-up Evaluation of Air Force Blood Donors Screening Positive for Chagas Disease

  17. The early implementation of Trypanosoma cruzi antibody screening of donors and donations within England: preempting a problem.

    Science.gov (United States)

    Kitchen, Alan D; Hewitt, Patricia E; Chiodini, Peter L

    2012-09-01

    Trypanosoma cruzi is a parasitic infection endemic in Central and Southern America, but is spreading into nonendemic countries with migration of infected individuals from endemic countries. The parasite is transmitted by transfusion or transplantation and donation screening is performed routinely in endemic countries to prevent transmission. In situations where migrants from endemic countries have settled in nonendemic countries and present as donors (blood or other cellular products), intervention is required to prevent transfusion or transplantation transmission. A screening program for T. cruzi was developed and has been used successfully for over 10 years that includes donor selection and donation screening. Donor selection criteria to identify specific risk of T. cruzi infection were developed together with laboratory screening of donations for T. cruzi antibodies and the subsequent confirmation of screen reactivity. Since the introduction of T. cruzi screening in England in 1998, a total of 38,585 donors and donations have been screened for T. cruzi antibodies, of which 223 were repeat reactive on screening and referred for confirmation: 206 confirmed negative, 14 inconclusive, and three positive. Since the move in 2005 from donor qualification to donation release testing, 15,536 donations were collected and screened, of which 15,499 (99.8%) were T. cruzi antibody negative and released to inventory. An effective program to minimize risk of the transmission of T. cruzi infection via donations has been developed and implemented. Not only does the program minimize risk of transmission, it also minimizes the cumulative, and needless, loss of donors and donations that would ensue if permanent donor deferral alone was adopted. © 2012 American Association of Blood Banks.

  18. Techniques used for the screening of hemoglobin levels in blood donors: current insights and future directions

    Directory of Open Access Journals (Sweden)

    Chaudhary R

    2017-07-01

    Full Text Available Rajendra Chaudhary,1 Anju Dubey,2 Atul Sonker3 1Department of Transfusion Medicine, Sanjay Gandhi Postgraduate Institute of Medical Sciences, 2Department of Transfusion Medicine, T.S. Misra Medical College and Hospital, 3Department of Transfusion Medicine, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, India Abstract: Blood donor hemoglobin (Hb estimation is an important donation test that is performed prior to blood donation. It serves the dual purpose of protecting the donors’ health against anemia and ensuring good quality of blood components, which has an implication on recipients’ health. Diverse cutoff criteria have been defined world over depending on population characteristics; however, no testing methodology and sample requirement have been specified for Hb screening. Besides the technique, there are several physiological and methodological factors that affect accuracy and reliability of Hb estimation. These include the anatomical source of blood sample, posture of the donor, timing of sample and several other biological factors. Qualitative copper sulfate gravimetric method has been the archaic time-tested method that is still used in resource-constrained settings. Portable hemoglobinometers are modern quantitative devices that have been further modified to reagent-free cuvettes. Furthermore, noninvasive spectrophotometry was introduced, mitigating pain to blood donor and eliminating risk of infection. Notwithstanding a tremendous evolution in terms of ease of operation, accuracy, mobility, rapidity and cost, a component of inherent variability persists, which may partly be attributed to pre-analytical variables. Hence, blood centers should pay due attention to validation of test methodology, competency of operating staff and regular proficiency testing of the outputs. In this article, we have reviewed various regulatory guidelines, described the variables that affect the measurements and compared the validated

  19. Dried blood spots of pooled samples for RHD gene screening in blood donors of mixed ancestry.

    Science.gov (United States)

    Silva-Malta, M C F; Araujo, N C Fidélis; Vieira, O V Neves; Schmidt, L Cayres; Gonçalves, P de Cassia; Martins, M Lobato

    2015-10-01

    In this study, we present a strategy for RHD gene screening based on real-time polymerase chain reaction (PCR) using dried blood spots of pooled samples. Molecular analysis of blood donors may be used to detect RHD variants among the presumed D-negative individuals. RHD genotyping using pooled samples is a strategy to test a large number of samples at a more reasonable cost. RHD gene detection based on real-time PCR using dried blood spots of pooled samples was standardised and used to evaluate 1550 Brazilian blood donors phenotyped as RhD-negative. Positive results were re-evaluated by retesting single samples using real-time PCR and conventional multiplex PCR to amplify five RHD-specific exons. PCR-sequence-specific primers was used to amplify RHDψ allele. We devised a strategy for RHD gene screening using dried blood spots of five pooled samples. Among 1550 serologically D-negative blood donors, 58 (3.74%) had the RHD gene. The non-functional RHDψ allele was detected in 47 samples (3.02%). The present method is a promising strategy to detect the RHD gene among presumed RhD-negative blood donors, particularly for populations with African ancestry. © 2015 British Blood Transfusion Society.

  20. Comparing prevalence of Iron Deficiency Anemia and Beta Thalassemia Trait in microcytic and non-microcytic blood donors: suggested algorithm for donor screening

    Directory of Open Access Journals (Sweden)

    Tiwari Aseem

    2009-01-01

    Full Text Available Background: The prevalence of microcytosis in donors and Iron Deficiency Anemia (IDA and Beta-Thalassemia trait (BTT in microcytic and non-microcytic donors has not been studied in India. The present study aims at finding the same. Materials and Methods: Initially 925 donor samples were evaluated on cell-counter. Of these, 50 were found to be microcytic. These were subjected to Ferritin and HbA2 determination. Subsequently, an additional 51, age-and-sex matched non-microcytic donor samples were selected to serve as controls. These were subjected to the same tests. Results: The prevalence of microcytosis was 5.4% (50/925. Among the microcytic donors, 52% were IDA, 36% BTT, 8% both, and 4% none. In case of non-microcytic donors 29.4% were IDA, 3.9% BTT, and 66.7% none. Conclusions: The study revealed a high prevalence of IDA and BTT in blood donors and a higher probability of finding these in the microcytic samples. This prompted authors to suggest an algorithm for screening of blood donors for IDA and BTT. The algorithm recommends doing an hemogram on all donor samples, routinely. Ferritin could be done only in microcytic samples. At levels lower than15 ng/ml, it is diagnosed as IDA, and therefore, HPLC is performed only for non-IDA samples with Ferritin levels higher than 15 ng/ml. By employing this algorithm, a substantial number of IDA and BTT could be diagnosed while keeping the number of Ferritin tests small and the number of HPLC tests even smaller and thus making it cost efficient.

  1. Evaluation of positive and false-positive results in syphilis screening of blood donors in Rio de Janeiro, Brazil.

    Science.gov (United States)

    Sandes, V S; Silva, S G C; Motta, I J F; Velarde, L G C; de Castilho, S R

    2017-06-01

    We propose to analyse the positive and false-positive results of treponemal and nontreponemal tests in blood donors from Brazil and to evaluate possible factors associated with the results of treponemal tests. Treponemal tests have been used widely for syphilis screening in blood banks. The introduction of these tests in donor screening has caused an impact and a loss of donors who need to be assessed. This was a retrospective cross-sectional study of syphilis screening and confirmatory test results of blood donors that were obtained before and after adopting a chemiluminescent immunoassay (CLIA). A comparative analysis was performed using a second sample drawn from positive donors. The possible factors associated with CLIA-positive or CLIA-false-positive results were investigated in a subgroup. Statistical tests were used to compare the proportions and adjusted estimates of association. The reactivity rate increased from 1·01% (N = 28 158) to 2·66% (N = 25 577) after introducing the new test. Among Venereal Disease Research Laboratory (VDRL)- and CLIA-confirmed results, the false-positive rates were 40·5% (N = 180) and 37·4% (N = 359), respectively (P = 0·5266). Older donors (OR = 1·04; P = 0·0010) and donors with lower education levels (OR = 6·59; P = 0·0029) were associated with a higher risk of positivity for syphilis. CLIA represents an improvement in blood bank serological screening. However, its use in a healthy population appears to result in high rates of false positives. Identifying which characteristics can predict false positives, however, remains a challenge. © 2017 British Blood Transfusion Society.

  2. Follow-up Evaluation of Air Force Blood Donors Screening Positive for Chagas Disease

    Science.gov (United States)

    2017-08-27

    Blood Donors Screening Positive for Cbagas Disease presented at/published to Military Health System Research Symposium (Florida, 27-30 Aug 2017) in...disease upon blood donation at JBSA -Lackland 6. TITLE OF MATERIAL TO BE PUBLISHED OR PRESENTED: Follow-up evaluation of Air Force blood donors ...Designated Exempt Reviewer Follow-up evaluation of Air Force blood donors screening positive for Chagas disease Joseph Marcus1, Bryant Webber2, Leo Cropper2

  3. Factors influencing the virological testing of cornea donors.

    Science.gov (United States)

    Röck, Tobias; Beck, Robert; Jürgens, Stefan; Bartz-Schmidt, Karl Ulrich; Bramkamp, Matthias; Thaler, Sebastian; Röck, Daniel

    2017-11-01

    To assess the influence of donor, environment, and logistical factors on the results of virological testing of blood samples from cornea donors.Data from 670 consecutive cornea donors were analyzed retrospectively. Logistic regression analysis was used to assess the influence of different factors on the results of virological testing of blood samples from cornea donors.The mean annual rate of donors with serology-reactive or not evaluable result was 14.8% (99 of 670) (range 11.9%-16.9%). The cause of donor death by cancer increased the risk of serology-reactive or not evaluable result (P = .0300). Prolonged time between death and post mortem blood removal was associated with a higher rate of serology-reactive or not evaluable result (P donors, sex, and donor age had no significant impact on the results of virological testing of blood samples from cornea donors.The cause of donor death by cancer and a prolonged time between death and post mortem blood removal seem to be mainly responsible for serology-reactive or not evaluable result of blood samples from cornea donors. The percentage of discarded corneas caused by serology-reactive or not evaluable result may be reduced by shortening the period of time between death and post mortem blood removal. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  4. Evaluation of the Procleix Ultrio Elite Assay and the Panther-System for Individual NAT Screening of Blood, Hematopoietic Stem Cell, Tissue and Organ Donors

    Science.gov (United States)

    Heim, Albert

    2016-01-01

    Summary Background The performance of the multiplex Procleix Ultrio Elite assay as individual donor nucleic acid test (ID-NAT) for the detection of HIV-1, HIV-2, HCV, and HBV was evaluated in a retrospective, single center study. Methods ID-NAT results of 21,181 blood donors, 984 tissue donors, 293 hematopoietic stem cell donors and 4 organ donors were reviewed in synopsis with results of serological screening and additional discriminatory and repetitive NAT in case of positive donors. Results Specificity of the initial Procleix Ultrio Elite assay was 99.98% and after discriminatory testing 100.00%. Initially invalid results were observed in 75 of 21,181 blood donors (0.35%) but 16 of 984 tissue donors (1.62%, p donors. All these had valid negative ID-NAT results after repeated testing or testing of 1:5 diluted specimens in case of tissue donors. Occult hepatitis B (defined here as HBV DNAemia without HBsAg detection) was demonstrated by ID-NAT in two anti-HBc-positive tissue donors and suspected in two other tissue donors, where a definite diagnosis was not achieved due to the insufficient sample volumes available. Conclusion The Procleix Ultrio Elite assay proved to be specific, robust and rapid. Therefore, routine ID-NAT may also be feasible for organ and granulocyte donors. PMID:27403089

  5. Evaluation of the Procleix Ultrio Elite Assay and the Panther-System for Individual NAT Screening of Blood, Hematopoietic Stem Cell, Tissue and Organ Donors.

    Science.gov (United States)

    Heim, Albert

    2016-05-01

    The performance of the multiplex Procleix Ultrio Elite assay as individual donor nucleic acid test (ID-NAT) for the detection of HIV-1, HIV-2, HCV, and HBV was evaluated in a retrospective, single center study. ID-NAT results of 21,181 blood donors, 984 tissue donors, 293 hematopoietic stem cell donors and 4 organ donors were reviewed in synopsis with results of serological screening and additional discriminatory and repetitive NAT in case of positive donors. Specificity of the initial Procleix Ultrio Elite assay was 99.98% and after discriminatory testing 100.00%. Initially invalid results were observed in 75 of 21,181 blood donors (0.35%) but 16 of 984 tissue donors (1.62%, p donors. All these had valid negative ID-NAT results after repeated testing or testing of 1:5 diluted specimens in case of tissue donors. Occult hepatitis B (defined here as HBV DNAemia without HBsAg detection) was demonstrated by ID-NAT in two anti-HBc-positive tissue donors and suspected in two other tissue donors, where a definite diagnosis was not achieved due to the insufficient sample volumes available. The Procleix Ultrio Elite assay proved to be specific, robust and rapid. Therefore, routine ID-NAT may also be feasible for organ and granulocyte donors.

  6. Socioepidemiological screening of serologically ineligible blood donors due to Chagas disease for the definition of inconclusive cases

    Directory of Open Access Journals (Sweden)

    Márcia M Ferreira-Silva

    2010-09-01

    Full Text Available Epidemiological screening combined with serological tests has become an important tool at blood banks for the characterization of donors with or without Trypanosoma cruzi infection. Thus, the objective of the present study was to describe the sociodemographic and epidemiological characteristics of blood donors with non-negative serology for T. cruzito determine possible risk factors associated with serological ineligibility. Sociodemographic and epidemiological data were collected by analysis of patient histories and interviews. The data were analyzed descriptively using absolute and relative frequencies and odds ratio (OR evaluation. The frequency of serological ineligibility was 0.28%, with a predominance of inconclusive reactions (52% and seropositivity among first-time donors (OR = 607, donors older than 30 years (OR = 3.7, females (OR = 1.9, donors from risk areas (OR = 4 and subjects living in rural areas (OR = 1.7. The risk of seropositivity was higher among donors who had contact with the triatomine vector (OR = 11.7 and those with a family history of Chagas disease (OR = 4.8. The results demonstrate the value of detailed clinical-epidemiological screening as an auxiliary tool for serological definition that, together with more specific and more sensitive laboratory methods, will guarantee a higher efficacy in the selection of donors at blood centres.

  7. Recall of symptoms and treatment of syphilis and yaws by healthy blood donors screening positive for syphilis in Kumasi, Ghana

    Directory of Open Access Journals (Sweden)

    Francis Sarkodie

    2016-09-01

    Conclusions: A small proportion of confirmed seroreactive donors in this sample had any recall of symptoms or treatment for yaws or syphilis. These data suggest that clinical questioning adds little further information to the current screening algorithm. The relative contribution of yaws and syphilis to frequent positive tests in endemic areas remains speculative.

  8. Characterization of human organ donors testing positive for type 1 diabetes-associated autoantibodies

    Science.gov (United States)

    Wiberg, A; Granstam, A; Ingvast, S; Härkönen, T; Knip, M; Korsgren, O; Skog, O

    2015-01-01

    In this study we aim to describe the characteristics of non-diabetic organ donors with circulating diabetes-associated autoantibodies collected within the Nordic Network for Islet Transplantation. One thousand and thirty organ donors have been screened in Uppsala for antibodies against glutamic acid decarboxylase (GADA) and islet antigen-2 (IA-2A). The 32 non-diabetic donors that tested positive for GADA (3·3% of all non-diabetic donors) were studied in more detail, together with 32 matched controls. Mean age among the autoantibody-positive donors was 52·6 (range 21–74), family history of type 1 diabetes (T1D) was unknown, and no donor was genetically predisposed for T1D regarding the human leucocyte antigen (HLA) locus. Subjects were analysed for islet cell antibodies (ICA), insulin autoantibodies (IAA) and zinc transporter 8 antibodies (ZnT8A), and pancreas morphology and clinical data were examined. Eight non-diabetic donors tested positive for two antibodies and one donor tested positive for four antibodies. No insulitis or other signs of a diabetic process were found in any of the donors. While inflammatory cells were present in all donors, subjects with high GADA titres had significantly higher CD45 cell numbers in exocrine tissue than controls. The extent of fibrosis was more pronounced in autoantibody-positive donors, even in subjects with lower GADA titres. Notably, it is possible that events not related directly to T1D (e.g. subclinical pancreatitis) may induce autoantibodies in some cases. PMID:26313035

  9. Factors affecting the serological testing of cadaveric donor cornea

    Directory of Open Access Journals (Sweden)

    Anuradha Raj

    2018-01-01

    Full Text Available Purpose: The purpose of this study was to evaluate the serological profile of the eye donors and to study the influence of various factors on serological test results. Methods: A cross-sectional, observational study was conducted, and data of 509 donors were reviewed from the records of eye bank from December 2012 to June 2017. Various details of donors analyzed included the age, sex of the donor, cause of death, source of tissue, time since blood collection after death, macroscopic appearance of blood sample, and details of discarded tissues. Serological examination of blood was performed for human immunodeficiency virus (HIV, hepatitis B virus, hepatitis C virus (HCV, venereal disease research laboratory (VDRL, and serology reports reactive or nonreactive were analyzed. Results: Among the 509 donors, 295 (58% were male, and 420 (82.50% belonged to age group ≥60 years. Most donors (354, 69.5% died due to cardiac arrest. Macroscopically, sera were normal in the majority of 488 (95.9% cases. Among 509 donors, 475 (93.3% were nonreactive, 12 (2.4% donors were found to be reactive to hepatitis B surface antigen (HBsAg, and 1 (0.2% was reactive to HCV, but no donor serology was reactive to HIV or VDRL. Twenty-one (4.12% donors' sera were not fit for serological testing. Among all donors, 475 (93.32% donors were accepted and 34 (6.67% were rejected or discarded on the basis of serological testing. Cause of death and macroscopic aspect of sera influenced the serological results in a highly significant manner (P = 0.00. Acceptance or rejection of the donor was significantly influenced by the serological results of the donor (P = 0.00. Conclusion: The seroprevalence among eye donor for HBsAg and HCV was 12 (2.4% and 1 (0.2%, respectively. Factors such as cause of death and macroscopic aspect of sera influence the serological results. Time since blood collection or sampling will not show any impact on viral serological results if postmortem sampling

  10. Factors affecting the serological testing of cadaveric donor cornea.

    Science.gov (United States)

    Raj, Anuradha; Mittal, Garima; Bahadur, Harsh

    2018-01-01

    The purpose of this study was to evaluate the serological profile of the eye donors and to study the influence of various factors on serological test results. A cross-sectional, observational study was conducted, and data of 509 donors were reviewed from the records of eye bank from December 2012 to June 2017. Various details of donors analyzed included the age, sex of the donor, cause of death, source of tissue, time since blood collection after death, macroscopic appearance of blood sample, and details of discarded tissues. Serological examination of blood was performed for human immunodeficiency virus (HIV), hepatitis B virus, hepatitis C virus (HCV), venereal disease research laboratory (VDRL), and serology reports reactive or nonreactive were analyzed. Among the 509 donors, 295 (58%) were male, and 420 (82.50%) belonged to age group ≥60 years. Most donors (354, 69.5%) died due to cardiac arrest. Macroscopically, sera were normal in the majority of 488 (95.9%) cases. Among 509 donors, 475 (93.3%) were nonreactive, 12 (2.4%) donors were found to be reactive to hepatitis B surface antigen (HBsAg), and 1 (0.2%) was reactive to HCV, but no donor serology was reactive to HIV or VDRL. Twenty-one (4.12%) donors' sera were not fit for serological testing. Among all donors, 475 (93.32%) donors were accepted and 34 (6.67%) were rejected or discarded on the basis of serological testing. Cause of death and macroscopic aspect of sera influenced the serological results in a highly significant manner (P = 0.00). Acceptance or rejection of the donor was significantly influenced by the serological results of the donor (P = 0.00). The seroprevalence among eye donor for HBsAg and HCV was 12 (2.4%) and 1 (0.2%), respectively. Factors such as cause of death and macroscopic aspect of sera influence the serological results. Time since blood collection or sampling will not show any impact on viral serological results if postmortem sampling will be done in donor cornea.

  11. PREVALENCE OF ANTI-HBC IN SLOVENIAN BLOOD DONORS AND THE IMPACTON BLOOD SCREENING

    Directory of Open Access Journals (Sweden)

    Snežana Levičnik Stezinar

    2008-04-01

    Among screened donors, the anti-HBc incidence rate was 179/5959 (3.00 %. Therewere 55 samples that were anti-HBc positive only (69.83 % of anti-HBc pos, 0.90 % of alldonations. The number of units positive for both antibodies was 124 (2.10 % of all testeddonations. No significant difference was noted in the prevalence between male (3.00 %and female (2.99 %. As expected, there was a raise in frequency from 0.78 % in a group of18–29 years to 5.82 % in a group 50–65 years. In the study group there was one donorwho was HBsAg carrier.Conclusion According to the results of this study, Slovenia is ranged among the countries with mediumanti-HBc prevalence rate. Screening of donors would additionally contribute to the higherblood safety. The higher cost due to testing and destroying units is not acceptable, especiallyafter the implementation of screening for HBV DNA and excluding the units that are reallyinfectious

  12. Abnormal Cervical Cancer Screening Test Results

    Science.gov (United States)

    ... AQ FREQUENTLY ASKED QUESTIONS FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test ...

  13. Comparison of three noninvasive methods for hemoglobin screening of blood donors.

    Science.gov (United States)

    Ardin, Sergey; Störmer, Melanie; Radojska, Stela; Oustianskaia, Larissa; Hahn, Moritz; Gathof, Birgit S

    2015-02-01

    To prevent phlebotomy of anemic individuals and to ensure hemoglobin (Hb) content of the blood units, Hb screening of blood donors before donation is essential. Hb values are mostly evaluated by measurement of capillary blood obtained from fingerstick. Rapid noninvasive methods have recently become available and may be preferred by donors and staff. The aim of this study was to evaluate for the first time all different noninvasive methods for Hb screening. Blood donors were screened for Hb levels in three different trials using three different noninvasive methods (Haemospect [MBR Optical Systems GmbH & Co. KG], NBM 200 [LMB Technology GmbH], Pronto-7 [Masimo Europe Ltd]) in comparison to the established fingerstick method (CompoLab Hb [Fresenius Kabi GmbH]) and to levels obtained from venous samples on a cell counter (Sysmex [Sysmex Europe GmbH]) as reference. The usability of the noninvasive methods was assessed with an especially developed survey. Technical failures occurred by using the Pronto-7 due to nail polish, skin color, or ambient light. The NBM 200 also showed a high sensitivity to ambient light and noticeably lower Hb levels for women than obtained from the Sysmex. The statistical analysis showed the following bias and standard deviation of differences of all methods in comparison to the venous results: Haemospect, -0.22 ± 1.24; NBM, 200 -0.12 ± 1.14; Pronto-7, -0.50 ± 0.99; and CompoLab Hb, -0.53 ± 0.81. Noninvasive Hb tests represent an attractive alternative by eliminating pain and reducing risks of blood contamination. The main problem for generating reliable results seems to be preanalytical variability in sampling. Despite the sensitivity to environmental stress, all methods are suitable for Hb measurement. © 2014 AABB.

  14. Pre-donation screening of volunteer prisoner blood donors for hepatitis B and C in prisons of punjab pakistan

    International Nuclear Information System (INIS)

    Pervaiz, A.; Sipra, F.S.; Rana, T.H.; Qadeer, I.

    2015-01-01

    Prisoners as a high risk group are never recommended for blood donations. In Pakistan, prisoners are legally allowed to donate blood and get thirty days extra remission. Inspectorate of prisons allowed Alizaib Foundation for blood donation camps subject to pre-donation screening of volunteer prisoner blood donor against infectious diseases. This study was conducted to identify the potential benefits of pre-donation screening. Methods: This cross sectional study was conducted in October, 2009 in Punjab. Intending volunteer prisoner blood donors from January, 2007 to September, 2009 from prisons of Punjab were included. Physically fit were tested for Hepatitis C Virus (HCV) and B Virus (HBV) by Rapid test kit before bleeding. Data was analysed by Epi-Info. Results: A total of 5894 male volunteer prisoner donors were screened and 1038 (17.6%) were rejected. The mean age was 28 years (range: 17-70 years). Of 5894, 857 (14.5%) were HCV positive and 222 (3.8%) were HBV positive. HCV and HBV co-infection was present among 41 (0.7%). Being convicted prisoner blood donor is significantly associated with higher seroprevalence for HCV (OR 1.35, 95% C.I. 1.17-1.57) and being under trial prisoner is significantly associated with higher seroprevalence for HBV (OR 1.40, 95% C.I. 1.06-1.85). Conclusion: Hepatitis B and C viruses were responsible for almost 18% prisoner blood donor rejection. Pre-donation screening of blood donors is an effective intervention to improve the safety and limit the cost of blood. Treatment of identified cases may contribute to public health. In the international scenario this study findings necessitate the amendments in the relevant prison rules. (author)

  15. Impact of screening for metabolic syndrome on the evaluation of obese living kidney donors.

    Science.gov (United States)

    Marcusa, Daniel P; Schaubel, Douglas E; Woodside, Kenneth J; Sung, Randall S

    2018-01-01

    We report our experience with metabolic syndrome screening for obese living kidney donor candidates to mitigate the long-term risk of CKD. We retrospectively reviewed 814 obese (BMI≥30) and 993 nonobese living kidney donor evaluations over 12 years. Using logistic regression, we explored interactions between social/clinical variables and candidate acceptance before and after policy implementation. Obese donor candidate acceptance decreased after metabolic syndrome screening began (56.3%, 46.3%, p metabolic syndrome, there was no significant change in how age, sex, race, or BMI affected a donor candidate's probability of acceptance. Metabolic syndrome screening is a simple stratification tool for centers with liberal absolute BMI cut-offs to exclude potentially higher-risk obese candidates. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Screening Tests for Birth Defects

    Science.gov (United States)

    ... that best fit your needs. What are the advantages and disadvantages of diagnostic tests compared with screening ... Us Contact Us Copyright Information Privacy Statement RSS Advertising Opportunities Careers at ACOG Sitemap Website Feedback American ...

  17. A web-based application for initial screening of living kidney donors: development, implementation and evaluation.

    Science.gov (United States)

    Moore, D R; Feurer, I D; Zavala, E Y; Shaffer, D; Karp, S; Hoy, H; Moore, D E

    2013-02-01

    Most centers utilize phone or written surveys to screen candidates who self-refer to be living kidney donors. To increase efficiency and reduce resource utilization, we developed a web-based application to screen kidney donor candidates. The aim of this study was to evaluate the use of this web-based application. Method and time of referral were tabulated and descriptive statistics summarized demographic characteristics. Time series analyses evaluated use over time. Between January 1, 2011 and March 31, 2012, 1200 candidates self-referred to be living kidney donors at our center. Eight hundred one candidates (67%) completed the web-based survey and 399 (33%) completed a phone survey. Thirty-nine percent of donors accessed the application on nights and weekends. Postimplementation of the web-based application, there was a statistically significant increase (p web-based application as opposed to telephone contact. Also, there was a significant increase (p = 0.025) in the total number of self-referrals post-implementation from 61 to 116 per month. An interactive web-based application is an effective strategy for the initial screening of donor candidates. The web-based application increased the ability to interface with donors, process them efficiently and ultimately increased donor self-referral at our center. © Copyright 2012 The American Society of Transplantation and the American Society of Transplant Surgeons.

  18. Newborn Screening Tests

    Science.gov (United States)

    ... don't have enough biotinidase, an enzyme that recycles biotin (a B vitamin) in the body. Biotinidase ... about additional tests: Do you have a family history of an inherited disorder? Have you previously given ...

  19. PREVENTION OF POST-TRANSFUSION HEPATITIS BY SCREENING OF ANTIBODY TO HEPATITIS B CORE ANTIGEN IN HEALTHY BLOOD DONORS

    Directory of Open Access Journals (Sweden)

    Sudha Bhat

    2011-01-01

    Full Text Available

    Background: Transfusion-associated hepatitis B viral infection continues to be a major problem in India even after adoption of mandatory screening for HBsAg by ELISA method. The high incidence of TAHBV is reported in patients receiving multiple transfusions.

    Objective: To study the seroprevalence of hepatitis B core antibody among healthy voluntary blood donors

    Subjects and Methods: The study was conducted in the department of Transfusion Medicine of a tertiary care referral hospital. A total of 12,232 volunteers after passing through the stringent criteria were selected for blood donation. Donor samples were tested for all mandatory transfusion transmissible infections and anti HBc IgM (Monolisa HBc IgM PLUS:BIO-RAD, France. Reactive results were confirmed by repeat testing in duplicate. Donor data was analyzed using SPSS software and Chi-square test was used to calculate the significance of difference between the groups.

    Results:A total of 12,232 healthy voluntary blood donors were recruited. Majority (93.4% were males. Median age of donor population was 26 years (range: 18-60 years. Eighty six (0.7% were positive for HBsAg, which comes under “low prevalence (<2% zone” as per WHO. On screening for HBcAg Ig M, 15 (0.1% were found to be positive and none were HBsAg reactive. There was no significance of difference in the mean age between reactive and non-reactive donors.

    Conclusion:Evaluating the usefulness of anti-HBc screening is critical. Anti HBcAg IgM screening may be included in routine screening of donors as it is an indicator of occult HBV during window period. The cost and the unnecessary wastage of the blood units when they are positive for anti HBsAg along with the core antibody need to be studied.

     

  20. Review of Autism Screening Tests

    Directory of Open Access Journals (Sweden)

    Farin Soleimani

    2014-10-01

    Full Text Available Background: Autism is a neurodevelopmental disorder that onset in the first 3 years of life and led to lifelong disability.Despite the early onset of symptoms, diagnosis of thissyndromedoes not happenuntil severalyears later, somany childrenlosethe opportunityfor earlyintervention.There arevarious toolsforscreening anddiagnosis, buttheirdesign, strengths and weaknesses aredifferent. The aim of this study was assess these tools from various aspects to provide a comprehensive view. Materials and methods: This study is a narrative literature review on screeningtoolsof autism. Comprehensive searches of the scientific literature were conducted in textbooks and 8 electronic databases(proquest,wiley,google scholar,SID,Scopus, Web of Science ،Science Direct ، and Medline and Pediatric book. language restriction (Persian and English was applied. The search strategy consisted of keywords and medical subject headings for autism and various screening tests. Result: In this study, 28 screening tests were identified from 1992 to 2014. CHAT is oldest test and the most recent test is CAST The minimum age that can perform the screening is six months that related to ITC. Minimum time of testing was 5 minutes  for CHAT and the maximum time was 90-120 minutes for ASIEP-3.RAADS-R test was the highest specificity and specificity (100% and the lowest specificity was 14% in ESAT test Conclusion: The results of this study indicate that any of the autism screening tools consider specific skill and various aspects of the disease, careful evaluation is need to choose proper test.

  1. The ELPAT living organ donor Psychosocial Assessment Tool (EPAT): from 'what' to 'how' of psychosocial screening - a pilot study.

    Science.gov (United States)

    Massey, Emma K; Timmerman, Lotte; Ismail, Sohal Y; Duerinckx, Nathalie; Lopes, Alice; Maple, Hannah; Mega, Inês; Papachristou, Christina; Dobbels, Fabienne

    2018-01-01

    Thorough psychosocial screening of donor candidates is required in order to minimize potential negative consequences and to strive for optimal safety within living donation programmes. We aimed to develop an evidence-based tool to standardize the psychosocial screening process. Key concepts of psychosocial screening were used to structure our tool: motivation and decision-making, personal resources, psychopathology, social resources, ethical and legal factors and information and risk processing. We (i) discussed how each item per concept could be measured, (ii) reviewed and rated available validated tools, (iii) where necessary developed new items, (iv) assessed content validity and (v) pilot-tested the new items. The resulting ELPAT living organ donor Psychosocial Assessment Tool (EPAT) consists of a selection of validated questionnaires (28 items in total), a semi-structured interview (43 questions) and a Red Flag Checklist. We outline optimal procedures and conditions for implementing this tool. The EPAT and user manual are available from the authors. Use of this tool will standardize the psychosocial screening procedure ensuring that no psychosocial issues are overlooked and ensure that comparable selection criteria are used and facilitate generation of comparable psychosocial data on living donor candidates. © 2017 Steunstichting ESOT.

  2. Recall of symptoms and treatment of syphilis and yaws by healthy blood donors screening positive for syphilis in Kumasi, Ghana.

    Science.gov (United States)

    Sarkodie, Francis; Owusu-Dabo, Ellis; Hassall, Oliver; Bates, Imelda; Bygbjerg, Ib C; Ullum, Henrik

    2016-09-01

    To describe the recalled medical history, clinical manifestations, and treatment of yaws and syphilis by syphilis seroreactive blood donors in Kumasi, Ghana. Of the blood donors at Komfo Anokye Teaching Hospital, Kumasi, Ghana tested with the syphilis rapid diagnostic test (RDT) and later by rapid plasma reagin (RPR) test, 526 were seroreactive. Four hundred and seventy-one (89.5%) of these subjects were confirmed with the Ortho-Vitros Syphilis TP test as the gold standard and were interviewed to determine past or present clinical manifestations of yaws and syphilis. Of the 471 respondent donors, 28 (5.9%) gave a history of skin lesions and sores; four (14.3%) of these subjects, who were all male and RPR-positive, recalled a diagnosis of syphilis. All four reported having had skin lesions/bumps with slow-healing sores, but only one of them had had these symptoms before the age of 15 years. A small proportion of confirmed seroreactive donors in this sample had any recall of symptoms or treatment for yaws or syphilis. These data suggest that clinical questioning adds little further information to the current screening algorithm. The relative contribution of yaws and syphilis to frequent positive tests in endemic areas remains speculative. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  3. Chemical compatibility screening test results

    International Nuclear Information System (INIS)

    Nigrey, P.J.; Dickens, T.G.

    1997-12-01

    A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) a mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60 degrees C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m 2 for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals

  4. Evaluation of the use of real-time PCR for human T cell lymphotropic virus 1 and 2 as a confirmatory test in screening for blood donors Análise do uso da PCR em tempo real para HTLV-1 e 2 como teste confirmatório na triagem de doadores de sangue

    Directory of Open Access Journals (Sweden)

    Rafaela Gomes Andrade

    2010-04-01

    Full Text Available INTRODUCTION: HTLV-1/2 screening among blood donors commonly utilizes an enzyme-linked immunosorbent assay (EIA, followed by a confirmatory method such as Western blot (WB if the EIA is positive. However, this algorithm yields a high rate of inconclusive results, and is expensive. METHODS: Two qualitative real-time PCR assays were developed to detect HTLV-1 and 2, and a total of 318 samples were tested (152 blood donors, 108 asymptomatic carriers, 26 HAM/TSP patients and 30 seronegative individuals. RESULTS: The sensitivity and specificity of PCR in comparison with WB results were 99.4% and 98.5%, respectively. PCR tests were more efficient for identifying the virus type, detecting HTLV-2 infection and defining inconclusive cases. CONCLUSIONS: Because real-time PCR is sensitive and practical and costs much less than WB, this technique can be used as a confirmatory test for HTLV in blood banks, as a replacement for WB.INTRODUÇÃO: A triagem para HTLV-1/2 em doadores de sangue geralmente utiliza imunoensaio enzimático, seguido de um método confirmatório como Western blot quando o EIA é positivo, mas este algoritmo mostra alta taxa de resultados inconclusivos, e elevado custo. MÉTODOS: Dois ensaios qualitativos de PCR em tempo real foram desenvolvidos para detectar HTLV-1 e 2 e um total de 318 amostras foram testadas por PCR (152 de doadores de sangue, 108 de portadores assintomáticos, 26 de pacientes HAM/TSP e 30 de indivíduos soronegativos. RESULTADOS: A sensibilidade e especificidade das PCR em relação aos resultados de WB foram de 99,4% e 98,5%, respectivamente. As PCR foram mais eficientes em identificar o tipo viral, a infecção pelo HTLV-2 e úteis para definir casos inconclusivos. CONCLUSÕES: Por serem sensíveis, práticas e de custo muito inferior ao do WB, as técnicas de PCR em tempo real podem ser usadas como teste confirmatório do HTLV em bancos de sangue, em substituição ao WB.

  5. Recall of symptoms and treatment of syphilis and yaws by healthy blood donors screening positive for syphilis in Kumasi, Ghana

    DEFF Research Database (Denmark)

    Sarkodie, Francis; Owusu-Dabo, Ellis; Hassall, Oliver

    2016-01-01

    the age of 15 years. Conclusions: A small proportion of confirmed seroreactive donors in this sample had any recall of symptoms or treatment for yaws or syphilis. These data suggest that clinical questioning adds little further information to the current screening algorithm. The relative contribution......) and later by rapid plasma reagin (RPR) test, 526 were seroreactive. Four hundred and seventy-one (89.5%) of these subjects were confirmed with the Ortho-Vitros Syphilis TP test as the gold standard and were interviewed to determine past or present clinical manifestations of yaws and syphilis. Results...

  6. [Evaluation of the efficacy of medical screening of blood donors on preventing blood transfusion-transmitted infectious agents].

    Science.gov (United States)

    Seck, M; Dièye, B; Guèye, Y B; Faye, B F; Senghor, A B; Toure, S A; Dieng, N; Sall, A; Toure, A O; Dièye, T N; Diop, S

    2016-05-01

    The aim of this study was to evaluate the efficacy of medical screening to retain blood donors in window period by comparing the seroprevalence of infectious agents (HIV, hepatitis B and C, syphilis) in deferred versus accepted blood donors. This prospective and transversal study was performed during 4 months in the National Blood Transfusion Center in Dakar (Senegal). We conducted a convenience sampling comparing the seroprevalence of infectious agents (HIV, HBsAg, HCV and syphilis) in deferred versus accepted blood donors after medical selection. In total, 8219 blood donors were included. Medical selection had authorized 8048 donors (97.92%) and deferred donors were 171 (2.08%). The prevalence of HIV was higher in the deferred than in accepted blood donors (1.75% vs. 0.05%) (P=0.0003; OR=35.91), as well as for HBsAg (12.87% vs. 7.35%) (P=0.006; OR=1.86). HCV antibodies were present in 0.71% of accepted blood donors and 0.58% in deferred blood donors (P=0.65; OR=0.82). Only accepted donors had brought the infection of syphilis (0.34%) (P=0.56; OR=0). Medical selection is efficient to exclude blood donors at high risk of HIV transmission and to a lesser extent of HBV. However, current medical screening procedures do not allow us to exclude donors asymptomatic carriers of HCV and syphilis. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  7. Impact of preimplantation genetic screening on donor oocyte-recipient cycles in the United States.

    Science.gov (United States)

    Barad, David H; Darmon, Sarah K; Kushnir, Vitaly A; Albertini, David F; Gleicher, Norbert

    2017-11-01

    Our objective was to estimate the contribution of preimplantation genetic screening to in vitro fertilization pregnancy outcomes in donor oocyte-recipient cycles. This was a retrospective cross-sectional study of US national data from the Society for Assisted Reproductive Technology Clinic Outcome Reporting System between 2005 and 2013. Society for Assisted Reproductive Technology Clinic Outcome Reporting relies on voluntarily annual reports by more than 90% of US in vitro fertilization centers. We evaluated pregnancy and live birth rates in donor oocyte-recipient cycles after the first embryo transfer with day 5/6 embryos. Statistical models, adjusted for patient and donor ages, number of embryos transferred, race, infertility diagnosis, and cycle year were created to compare live birth rates in 392 preimplantation genetic screening and 20,616 control cycles. Overall, pregnancy and live birth rates were significantly lower in preimplantation genetic screening cycles than in control cycles. Adjusted odds of live birth for preimplantation genetic screening cycles were reduced by 35% (odds ratio, 0.65, 95% confidence interval, 0.53-0.80; P cycles over the past 9 years, has not been associated with improved odds of live birth or reduction in miscarriage rates. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. 21 CFR 1271.80 - What are the general requirements for donor testing?

    Science.gov (United States)

    2010-04-01

    ... ADMINISTRATION HUMAN CELLS, TISSUES, AND CELLULAR AND TISSUE-BASED PRODUCTS Donor Eligibility § 1271.80 What are... mother instead of a specimen from the donor. (b) Timing of specimen collection. You must collect the donor specimen for testing at the time of recovery of cells or tissue from the donor; or up to 7 days...

  9. Zero risk tolerance costs lives: loss of transplantable organs due to human immunodeficiency virus nucleic acid testing of potential donors.

    Science.gov (United States)

    Shafer, Teresa J; Schkade, David; Schkade, Lawrence; Geier, Steven S; Orlowski, Jeffrey P; Klintmalm, Goran

    2011-09-01

    Patients' deaths due to the organ donor shortage make it imperative that every suitable organ be transplanted. False-positive results of tests for infection with the human immunodeficiency virus (HIV) result in lost organs. A survey of US organ procurement organizations collected the numbers of donors and ruled-out potential donors who had a positive result on an HIV test from January 1,2006, to October 31, 2008. Sixty-two percent of US organ procurement organizations participated. Of the 12397 donor/nondonor cases, 56 (0.45%) had an initial positive result on an HIV antibody or HIV nucleic acid test, and only 8 (14.3%) of those were confirmed positive. Of the false-positive results, 50% were from HIV antibody tests and 50% were from HIV nucleic acid tests. Organs are a scarce, finite, and perishable resource. Use of HIV antibody testing has produced a remarkably safe track record of avoiding HIV transmission, with 22 years of nonoccurrence between transmissions. Because false positives occur with any test, including the HIV Ab test, adding nucleic acid testing to the standard donor testing panel doubles the number of false-positive HIV test results and thus the number of medically suitable donors lost. The required HIV antibody test is 99.99% effective in preventing transmission of the HIV virus. Adding the HIV nucleic acid test to routine organ donor screening could result in as many as 761 to 1551 unnecessary deaths of patients between HIV transmission events because medically suitable organs are wasted.

  10. Screening of post-mortem tissue donors for Coxiella burnetii infection after large outbreaks of Q fever in The Netherlands

    NARCIS (Netherlands)

    van Wijk, Marja J.; Maas, D. Willemijn; Renders, Nicole H. M.; Hermans, Mirjam H. A.; Zaaijer, Hans L.; Hogema, Boris M.

    2014-01-01

    After the largest outbreaks of Q fever ever recorded in history occurred in the Netherlands, concern arose that Coxiella may be transmitted via donated tissues of latent or chronically infected donors. The Dutch Health Council recently advised to screen tissue donors, donating high risk tissues, for

  11. Factors associated with failure of clinical screening among blood donors who have altered serological results in the Centro Regional de Hemoterapia de Ribeirão Preto

    Directory of Open Access Journals (Sweden)

    Oranice Ferreira

    2012-01-01

    Full Text Available OBJECTIVE: This study aimed to investigate the frequency of positive results for hepatitis B and C, HIV and syphilis in blood donations at the Centro Regional de Hemoterapia de Ribeirão Preto, to describe donors with positive results according to some demographic and socioeconomic variables, to identify risk factors associated to these donors and the reasons that they were not detected during clinical screening. METHODS: A descriptive study was performed between July 1st 2005 and July 31st 2006 by interviewing 106 donors after medical consultations where they were informed of positive results for hepatitis B, hepatitis C, HIV or syphilis. RESULTS: There was a predominance of first-time donors, males, under 50-year olds, married individuals, from Ribeirão Preto, with elementary education, low economic status and of people who donated at the request of friends or relatives. Hepatitis C was the most frequently detected infection (56.6%, followed by hepatitis B (20.7%, HIV (12.3% and syphilis(10.4%. About 40% of donors had omitted risk factors for different reasons: because they trusted the results of serological tests, did not feel comfortable about talking of risk factors or did not consider them relevant. Other justifications were the duration of the interview, the interviewer was unskilled, embarrassment and doubts about confidentiality. CONCLUSION: The results indicate the need for changes in the approach to clinical screening and a review of methods to attract and guide potential donors.

  12. Testing Precision Screening for Breast Cancer

    Science.gov (United States)

    An NCI research article about individualized approaches that could help identify those at risk of breast cancer who need to be screened and testing screening intervals that are appropriate for each person’s level of risk.

  13. Investigation of an algorithm for anti HCV EIA reactivity in blood donor screening in Turkey in the absence of nucleic acid amplification screening.

    Science.gov (United States)

    Karakoc, Ayse Esra; Berkem, Rukiye; Irmak, Hasan; Demiroz, Ali Pekcan; Yenicesu, Idil; Ertugrul, Nigar; Arslan, Önder; Kemahli, Sabri; Yilmaz, Sevinc; Ozcebe, Osman; Kara, Abdurrahman; Ozet, Gulsum; Acikgoz, Ziya Cibali; Acikgoz, Tulin

    2017-10-01

    In this study we aimed to propose an algorithm for initial anti HCV EIA reactive blood donations in Turkey where nucleic acid amplification tests are not yet obligatory for donor screening. A total of 416 anti HCV screening test reactive donor samples collected from 13 blood centers from three cities in Turkey were tested in duplicate by Ortho HCV Ab Version 3.0 and Radim HCV Ab. All the repeat reactive samples were tested by INNO-LIA HCV Ab 3.0 or Chiron RIBA HCV 3.0 and Abbott Real Time HCV. Intra-assay correlations were calculated with Pearson r test. ROC analysis was used to study the relationship between EIA tests and the confirmatory tests. The number of repeat reactive results with Ortho EIA were 221 (53.1%) whereas that of microEIA, 62 (14.9%). Confirmed positivity rate was 14.6% (33/226) by RIBA and 10.6% (24/226) by NAT. Reactive PCR results were predicted with 100% sensitivity and 95% specificity with S/CO levels of 8.1 with Ortho EIA and 3.4 with microEIA. Repeat reactivity rates declined with a second HCV antibody assay. Samples repeat reactive with one HCV antibody test and negative with the other were all NAT negative. All the NAT reactive samples were RIBA positive. None of the RIBA indeterminate or negative samples were NAT reactive. Considering the threshold values for EIA kits determined by ROC analysis NAT was decided to be performed for the samples above the threshold value and a validated supplemental HCV antibody test for the samples below. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Demographic, risk factors and motivations among blood donors with reactive serologic tests for syphilis in São Paulo, Brazil.

    Science.gov (United States)

    Ferreira, S C; de Almeida-Neto, C; Nishiya, A S; Oliveira, C D L; Ferreira, J E; Alencar, C S; Levi, J E; Salles, N A; Mendrone, A; Sabino, E C

    2014-06-01

    To identify the demographic characteristics, risk factors and motivations for donating among blood donors with reactive serologic tests for syphilis. Post-donation interviews with syphilis seropositive blood donors improve recruitment and screening strategies. This case-control study compares 75 Venereal Disease Research Laboratory (VDRL) > 8, EIA+ (enzyme immunoassay) and FTA-ABS+ (fluorescent treponemal antibody); 80 VDRL-, EIA+ and FTA-ABS+; and 34 VDRL- and EIA- donors between 2004 and 2009. Donors were assessed by their demographic characteristics, sexual behaviour, history of alcohol and illicit drugs use, and motivations to donate. Donors with VDRL > 8 were more likely to be divorced [AOR = 12·53; 95% confidence interval (CI) 1·30-120·81], to have had more than six sexual partners (AOR=7·1; 95% CI 1·12-44·62) and to report male-male-sex in the past 12 months (AOR=8·18; 95% CI 1·78-37·60). Donors with VDRL-, EIA+ and FTA-ABS+ were less likely to be female (AOR=0·26; 95% CI 0·07-0·96), more likely to be older (AOR=10·2; 95% CI 2·45-42·58 ≥ 39 and illicit drugs use; 30·7% (VDRL > 8) and 12·5% (VDRL-, EIA+ and FTA-ABS+) of donors reported that they had been at risk for HIV infection (P = 0·004). One-third of donors came to the blood bank to help a friend or a relative who needed blood. Although donors exposed to syphilis reported and recognised some high risk behaviour, most were motivated by direct appeal to donate blood. Monitoring the risk profile of blood donors can benefit public health and improve blood safety. © 2014 The Authors. Transfusion Medicine © 2014 British Blood Transfusion Society.

  15. The serological screening of deceased tissue donors within the English Blood Service for infectious agents--a review of current outcomes and a more effective strategy for the future.

    Science.gov (United States)

    Kitchen, A D; Gillan, H L

    2010-04-01

    The overall effectiveness of the NHSBT screening programme for infectious agents in deceased tissue donors is examined and evaluated in terms of current outcomes and how to improve upon these outcomes. The screening results and any subsequent confirmatory results from a total of 1659 samples from NHSBT deceased donors referred to NTMRL for screening for infectious agents were included in the analysis. Overall 1566/1659 (94.4%) of the samples were screen negative. A total of 93 were repeat reactive on screening for one or more of the mandatory markers screened for, of which only 12 (13%) were subsequently confirmed to be positive on confirmatory testing. The majority of the repeat reactive samples were demonstrating non-specific reactivity with the screening assays in use. Overall, the NHSBT screening programme for infectious agents in deceased tissue donors is very effective with a relatively low overall loss of donors because of non-specific reactivity. However, unnecessary loss of tissue products is not acceptable, and although this programme compares favourably with the outcomes of other such programmes, the confirmatory results obtained demonstrate both the need and the potential for improving the outcomes. This is particularly important as one donor may donate more than one product, and can be achieved very easily with a change to the screening algorithm followed, using the confirmatory data obtained to support and validate this change. CONTENTS SUMMARY: Critical analysis of the NHSBT screening programme for infectious agents in deceased tissue donors and a strategy involving the design and use of a different screening algorithm to improve these outcomes.

  16. Detection of occult hepatitis B and window period infection among blood donors by individual donation nucleic acid testing in a tertiary care center in South India.

    Science.gov (United States)

    Keechilot, Cinzia S; Shenoy, Veena; Kumar, Anil; Biswas, Lalitha; Vijayrajratnam, Sukhithasri; Dinesh, Kavitha; Nair, Prem

    With the introduction of highly sensitive hepatitis B surface antigen immunoassay, transfusion associated HBV infection have reduced drastically but they still tend to occur due to blood donors with occult hepatitis B infection (OBI) and window period (WP) infection. Sera from, 24338 healthy voluntary blood donors were screened for HBsAg, HIV and HCV antibody using Vitros Enhanced Chemiluminescent Immunoassay. The median age of the donor population was 30 (range 18-54) with male preponderance (98%). All serologically negative samples were screened by nucleic acid testing (NAT) for viral DNA and RNA. NAT-positive samples were subjected to discriminatory NAT for HBV, HCV, and HIV and all samples positive for HBV DNA were tested for anti-HBc, anti-HBs, HBeAg. Viral load was determined using artus HBV RG PCR Kit. Of the 24,338 donors screened, 99.81% (24292/24338) were HBsAg negative of which NAT was positive for HBV DNA in 0.0205% (5/24292) donors. Four NAT positive donors had viral load of <200 IU/ml making them true cases of OBI. One NAT positive donor was negative for all antibodies making it a case of WP infection. Among OBI donors, 75% (3/4) were immune and all were negative for HBeAg. Precise HBV viral load could not be determined in all (5/5) NAT positive donors due to viral loads below the detection limit of the artus HBV RG PCR Kit. The overall incidence of OBI and WP infections was found to be low at 1 in 6503 and 1 in 24214 donations, respectively. More studies are needed to determine the actual burden of WP infections in Indian blood donors.

  17. Screening and Invasive Testing in Twins

    Directory of Open Access Journals (Sweden)

    Giovanni Monni

    2014-07-01

    Full Text Available Prenatal screening and testing for trisomy 21 in twin pregnancies poses a number of challenges: the exact estimate of the a priori risk of trisomy 21, the choice of prenatal screening test and/or invasive techniques to employ for the diagnosis and the impact of the result on the options of treatment in case of discordant results within a twin pair or among multiples. These different aspects are discussed below while recognizing that many issues remain unresolved.

  18. [Generalized neonatal screening based on laboratory tests].

    Science.gov (United States)

    Ardaillou, Raymond; Le Gall, Jean-Yves

    2006-11-01

    Implementation of a generalized screening program for neonatal diseases must obey precise rules. The disease must be severe, recognizable at an early stage, amenable to an effective treatment, detectable with a non expensive and widely applicable test; it must also be a significant public health problem. Subjects with positive results must be offered immediate treatment or prevention. All screening programs must be regularly evaluated. In France, since 1978, a national screening program has been organized by a private association ("Association française pour le dépistage et la prévention des handicaps de l'enfant") and supervised by the "Caisse nationale d'assurance maladie" and "Direction Générale de la Sante". Five diseases are now included in the screening program: phenylketonuria, hypothyroidism, congenital adrenal hyperplasia, cystic fibrosis and sickle cell disease (the latter only in at-risk newborns). Toxoplasmosis is a particular problem because only the children of mothers who were not tested during the pregnancy or who seroconverted are screened. Neonatal screening for phenylketonuria and hypothyrodism is unanimously recommended. Screening for congenital adrenal hyperplasia is approved in most countries. Cases of sickle cell disease and cystic fibrosis are more complex because--not all children who carry the mutations develop severe forms;--there is no curative treatment;--parents may become anxious, even though the phenotype is sometimes mild or even asymptomatic. Supporters of screening stress the benefits of early diagnosis (which extends the life expectancy of these children, particularly in the case of sickle cell disease), the fact that it opens up the possibility of prenatal screening of future pregnancies, and the utility of informing heterozygous carriers identified by familial screening. Neonatal screening for other diseases is under discussion. Indeed, technical advances such as tandem mass spectrometry make it possible to detect about 50

  19. Umbilical cord blood units for public storage donors screening for markers of infectious agents

    Directory of Open Access Journals (Sweden)

    A. B. Smolyaninov

    2012-01-01

    Full Text Available The screening of 3515 cord blood samples which had entered bank for public use for presence of markers of infectious agents was carried out. It was established that majority of cord blood units contain markers of cytomegalovirus and Toxoplasma (81% that is not a contraindication for storage and subsequent use of these samples. In 4.6% of cases umbilical cord blood units were subjected to disposal because of identification of viral hepatitis B and C, as well as Tr. pallidum markers, moreover, the largest share of the discarded units contained antibodies to HbscorAg – 71,3%. Inclusion of analysis on the presence of Anti-HBcor in the required laboratory screening of mothers-donors CB was proposed in order to reduce the percentage of discarded umbilical cord blood units for the public inventory.

  20. Reactor operator screening test experiences

    International Nuclear Information System (INIS)

    O'Brien, W.J.; Penkala, J.L.; Witzig, W.F.

    1976-01-01

    When it became apparent to Duquesne Light Company of Pittsburgh, Pennsylvania, that the throughput of their candidate selection-Phase I training-reactor operator certification sequence was something short of acceptable, the utility decided to ask consultants to make recommendations with respect to candidate selection procedures. The recommendation implemented was to create a Nuclear Training Test that would predict the success of a candidate in completing Phase I training and subsequently qualify for reactor operator certification. The mechanics involved in developing and calibrating the Nuclear Training Test are described. An arbitration decision that resulted when a number of International Brotherhood of Electrical Workers union employees filed a grievance alleging that the selection examination was unfair, invalid, not job related, inappropriate, and discriminatorily evaluated is also discussed. The arbitration decision favored the use of the Nuclear Training Test

  1. Analyzing actual risk in malaria-deferred donors through selective serologic testing.

    Science.gov (United States)

    Nguyen, Megan L; Goff, Tami; Gibble, Joan; Steele, Whitney R; Leiby, David A

    2013-08-01

    Approximately 150,000 US blood donors are deferred annually for travel to malaria-endemic areas. However, the majority do not travel to the high-risk areas of Africa associated with transfusion-transmitted malaria (TTM) but visit low-risk areas such as Mexico. This study tests for Plasmodium infection among malaria-deferred donors, particularly those visiting Mexico. Blood donors deferred for malaria risk (travel, residence, or previous infection) provided blood samples and completed a questionnaire. Plasma was tested for Plasmodium antibodies by enzyme immunoassay (EIA); repeat-reactive (RR) samples were considered positive and tested by real-time polymerase chain reaction (PCR). Accepted donors provided background testing data. During 2005 to 2011, a total of 5610 malaria-deferred donors were tested by EIA, including 5412 travel deferrals. Overall, 88 (1.6%) were EIA RR; none were PCR positive. Forty-nine (55.7%) RR donors previously had malaria irrespective of deferral category, including 34 deferred for travel. Among 1121 travelers to Mexico, 90% visited Quintana Roo (no or very low risk), but just 2.2% visited Oaxaca/Chiapas (moderate or high risk). Only two Mexican travelers tested RR; both previously had malaria not acquired in Mexico. Travel to Mexico represents a large percentage of US donors deferred for malaria risk; however, these donors primarily visit no- or very-low-risk areas. No malaria cases acquired in Mexico were identified thereby supporting previous risk estimates. Consideration should be given to allowing blood donations from U.S. donors who travel to Quintana Roo and other low-risk areas in Mexico. A more effective approach to preventing TTM would be to defer all donors with a history of malaria, even if remote. © 2012 American Association of Blood Banks.

  2. Point-of-care testing in an organ procurement organization donor management setting.

    Science.gov (United States)

    Baier, K A; Markham, L E; Flaigle, S P; Nelson, P W; Shield, C F; Muruve, N A; Aeder, M I; Murillo, D; Bryan, C F

    2003-01-01

    Our organ procurement organization (OPO) evaluated the clinical and financial efficacy of point-of-care testing (POCT) in management of our deceased organ donors. Before we implemented point-of care testing with the i-STAT into routine clinical donor management, we compared the i-STAT result with the result from the respective donor hospital lab (DHL) for certain analytes on 15 consecutive donors in our OPO from 26 March to 14 May 2001. The financial impact was studied by reviewing 77 donors from July 2001 to March 2002. There was a strong correlation for each analyte between the POC and DHL test results with r-values as follows: pH 0.86; PCO2 = 0.96; PO2 = 0.98; sodium = 0.98; potassium = 0.95; chloride = 0.94; BUN = 0.98; glucose = 0.92; haematocrit = 0.87 and creatinine = 0.95. Since our OPO coordinators began using i-STAT in their routine clinical management of organ donors, they can now more quickly maximize oxygenation and fluid management of the donor and make extra-renal placement calls sooner. Finally, since we are no longer being billed for the testing performed on the i-STAT, average financial savings to our OPO are US dollars 733 per case. Point-of-care testing in management of our OPO donors provides a result that is equivalent to that of the donor hospital lab, has quicker turn-around time than the donor hospital laboratory, allowing more immediate clinical management decisions to be made so that extra-renal offers may begin sooner.

  3. The role of P24 antigen screening in reducing the risk of HIV transmission by scronegetive bone allograft donors

    International Nuclear Information System (INIS)

    Bryce, R.N.; Morgan, A.F.; Malhotra, R.

    1999-01-01

    Disease transmission is an infrequent but important risk associated with bone transplantation. Human immunodeficiency virus infection is particularly important because of delay in seroconversion of the potential donor. This is so-call 'window' period may extend for several months. Almost all human immunodeficiency virus transmission via the transplantation of blood or tissue since the implementation of anti-HIV screening in 1985 has been during this window period. The performance of newer assays to detect viral and serologic markers may reduce this risk of disease transmission. We present the strategy employed at the Queensland Bone Bank to minimise the risk of HIV transmission through an infected donor

  4. Cold Leak Tests of LHC Beam Screens

    CERN Document Server

    Collomb-Patton, C; Jenninger, B; Kos, N

    2009-01-01

    In order to guide the high energy proton beams inside its two 27 km long vacuum rings, the Large Hadron Collider (LHC) at CERN, Geneva, makes use of superconducting technology to create the required magnetic fields. More than 4000 beam screens, cooled at 7 20 K, are inserted inside the 1.9 K beam vacuum tubes to intercept beam induced heat loads and to provide dynamic vacuum stability. As extremely high helium leak tightness is required, all beam screens have been leak tested under cold conditions in a dedicated test stand prior to their installation. After describing the beam screen design and its functions, this report focuses on the cold leak test sequence and discusses the results.

  5. Test equality between two binary screening tests with a confirmatory procedure restricted on screen positives.

    Science.gov (United States)

    Lui, Kung-Jong; Chang, Kuang-Chao

    2015-01-01

    In studies of screening accuracy, we may commonly encounter the data in which a confirmatory procedure is administered to only those subjects with screen positives for ethical concerns. We focus our discussion on simultaneously testing equality of sensitivity and specificity between two binary screening tests when only subjects with screen positives receive the confirmatory procedure. We develop four asymptotic test procedures and one exact test procedure. We derive sample size calculation formula for a desired power of detecting a difference at a given nominal [Formula: see text]-level. We employ Monte Carlo simulation to evaluate the performance of these test procedures and the accuracy of the sample size calculation formula developed here in a variety of situations. Finally, we use the data obtained from a study of the prostate-specific-antigen test and digital rectal examination test on 949 Black men to illustrate the practical use of these test procedures and the sample size calculation formula.

  6. Cancer screening tests for small animals.

    Science.gov (United States)

    Schleis, Stephanie E

    2014-09-01

    Cancer is increasingly more common. Several tests for the diagnosis and treatment of cancer in companion animals have been developed. Screening tests discussed include those for lymphoid neoplasia, hemangiosarcoma, and transitional cell carcinoma of the bladder. None of these tests should be used in isolation for diagnosis. Vincristine and doxorubicin are mainstays in the treatment of canine lymphoma. However, it is important and accepted practice to test individuals of predisposed breeds for this mutation before administering these drugs in a lymphoma protocol. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Red cell antigen prevalence predicted by molecular testing in ethnic groups of South Texas blood donors.

    Science.gov (United States)

    Aranda, Lorena I; Smith, Linda A; Jones, Scott; Beddard, Rachel

    2015-01-01

    Alloimmunization to red blood cell antigens is seen in patients receiving chronic blood transfusion. Knowing the prevalence of blood group antigens of the different ethnicities of South Texas donors can provide better management of rare blood inventory for patients in this geographical area. A total of 4369 blood donors were tested and analyzed for various antigens in the following blood group systems: ABO, Rh, Kell, Duffy, Kidd, MNS, Lutheran, Dombrock, Landsteiner-Wiener, Diego, Colton, and Scianna. Donors tested to be group 0 or A were serologically tested for the Rh (C, E, c, e) antigens. Those that tested as presumably R1R1, R2R2, or Ror were then genotyped. Donors constituted three major ethnicities: black (18.3%), Hispanic (36.3%), and Caucasian (41.1%); ethnicities comprised of Asian, American Indian, multiracial, and other accounted for the remaining donors (4.3%). The most likely common Rh phenotype for each ethnicity is as follows: black -Ror (44.4%), Hispanic -R1R1 (59.0%), and Caucasian -R1R1 (38.9%). The prevalence of Kell, Duffy, and Kidd blood group system antigens in black and Caucasian donors is comparable with published reports for the entire U.S. The black South Texas donor population had an 8.8 percent increase in prevalence of the Fy(a+b-) phenotype as compared with these published reports; the Hispanic South Texas donor population had a prevalence of 36.1 percent of the Fy(a+b-) phenotype. Regarding the Diego blood group system, the Hispanic donor population in South Texas had a prevalence of 93.5 percent for the Di(a-b+) phenotype as compared with published reports for the entire U.S. (>99.9%). The Hispanic population had a prevalence of 7.9 percent of donors testing as M-N+S-s+ as compared with 20.2 percent and 15.6 percent for black and Caucasian donors, respectively. This study helped us determine the prevalence of each of the blood group antigens in the South Texas donor population to establish and maintain adequate rare inventory of

  8. Preoperative screening: value of previous tests.

    Science.gov (United States)

    Macpherson, D S; Snow, R; Lofgren, R P

    1990-12-15

    To determine the frequency of tests done in the year before elective surgery that might substitute for preoperative screening tests and to determine the frequency of test results that change from a normal value to a value likely to alter perioperative management. Retrospective cohort analysis of computerized laboratory data (complete blood count, sodium, potassium, and creatinine levels, prothrombin time, and partial thromboplastin time). Urban tertiary care Veterans Affairs Hospital. Consecutive sample of 1109 patients who had elective surgery in 1988. At admission, 7549 preoperative tests were done, 47% of which duplicated tests performed in the previous year. Of 3096 previous results that were normal as defined by hospital reference range and done closest to the time of but before admission (median interval, 2 months), 13 (0.4%; 95% CI, 0.2% to 0.7%), repeat values were outside a range considered acceptable for surgery. Most of the abnormalities were predictable from the patient's history, and most were not noted in the medical record. Of 461 previous tests that were abnormal, 78 (17%; CI, 13% to 20%) repeat values at admission were outside a range considered acceptable for surgery (P less than 0.001, frequency of clinically important abnormalities of patients with normal previous results with those with abnormal previous results). Physicians evaluating patients preoperatively could safely substitute the previous test results analyzed in this study for preoperative screening tests if the previous tests are normal and no obvious indication for retesting is present.

  9. [Mass neonatal screening using biological testing].

    Science.gov (United States)

    Ardaillou, R; Le Gall, J-Y

    2007-04-01

    Implementation of a generalized screening program for neonatal diseases obeys precise guidelines. The disease must be severe, recognizable at an early stage, accessible to an effective treatment, detected with a non expansive and widely applicable test and it must represent an important health problem. In case of positive results, treatment or prevention shall be offered immediately and any screening program has to be regularly evaluated. There is in France since 1978 a national screening program that depends on a private association ("Association française pour le dépistage et la prévention des handicaps de l'enfant") and is supervised by the "Caisse nationale d'assurance maladie" and the "Direction Générale de la Sante". Presently, five diseases are included in the screening program: phenylketonuria, hypothyroidism, congenital adrenal hyperplasia, cystic fibrosis and sickle cell disease, the latter only in at risk newborns. Toxoplasmosis represents a particular problem because screening takes place only in children of mothers that have not been controlled during their pregnancy or in case of seroconversion. Neonatal screening of phenylketonuria and hypothyrodism is unanimously recommended. That of congenital adrenal hyperplasia is approved in most countries. The cases of sickle cell disease and cystic fibrosis are more complex because: 1) all the children that carry the mutations are not affected with a severe disease; 2) there is no curative treatment; 3) parents given information are made anxious, sometimes wrongly if the disease is mild or asymptomatic. The supporters of the screening insist on the interest of an early diagnosis which makes longer the life time of these children, the possibility for the parents to utilize prenatal screening in case of a future pregnancy, and the information given to the heterozygous carriers following a familial screening. The question is raised of the extension of neonatal screening to other diseases. This is now

  10. Recruitment of feces donors among blood donors

    DEFF Research Database (Denmark)

    Dahl Jørgensen, Simon Mark; Erikstrup, Christian; Dinh, Khoa Manh

    2018-01-01

    As the use of fecal microbiota transplantation (FMT) has gained momentum, an increasing need for continuous access to healthy feces donors has developed. Blood donors constitute a healthy subset of the general population and may serve as an appropriate group for recruitment. In this study, we...... investigated the suitability of blood donors as feces donors. In a prospective cohort study, we recruited blood donors onsite at a public Danish blood bank. Following their consent, the blood donors underwent a stepwise screening process: First, blood donors completed an electronic pre-screening questionnaire...... to rule out predisposing risk factors. Second, eligible blood donors had blood and fecal samples examined. Of 155 blood donors asked to participate, 137 (88%) completed the electronic pre-screening questionnaire, 16 declined, and 2 were excluded. Of the 137 donors who completed the questionnaire, 79 (58...

  11. Sensitivity of nested-PCR for plasmodium detection in pooled whole blood samples and its usefulness to blood donor screening in endemic areas.

    Science.gov (United States)

    de Freitas, Daniel Roberto Coradi; Gomes, Luciano Teixeira; Fontes, Cor Jesus F; Tauil, Pedro Luiz; Pang, Lorrin W; Duarte, Elisabeth Carmen

    2014-04-01

    Transfusion-transmitted malaria is a severe disease with high fatality rate. Most Brazilian blood banks in the Amazon region perform malaria screening using microscopic examination (thick smears). Since low parasite concentrations are expected in asymptomatic blood donors a high sensitivity test should be used for donor screening. This study determined the sensitivity of a nested-PCR for plasmodium detection in pooled samples. We performed a one-stage criterion validation study with 21 positive samples pooled with samples from ten negative volunteer until three different concentrations were reached (0.33; 0.25; 0.20 parasites/μL - p/μL). Nested PCR was performed as described by Snounou et al. (1993). Sensitivities (and confidence intervals) were determined by stratum of final parasite concentration on the pooled samples. All samples with parasitemia values of 0.33 and 0.25 p/μL had 100% sensitivity (95%CI=86.3-100). One negative result was obtained from a sample with 0.20 p/μL sensitivity=95.2% (95%CI=76.2-99.9). Compared to parasitemia detectable under ideal conditions of thick smear, this nested-PCR in pooled sample was able to detect 40 times more parasites per microliter. Nested-PCR in pooled samples should be considered as a high sensitive alternative to thick smear for donor screening in blood banks at endemic regions. Local authorities need to assess cost:benefit advantages of this method compared to alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Current practices for screening, consent and care of related donors in France: Haematopoietic stem cell transplantation coordinator nurses' perceptions.

    Science.gov (United States)

    Polomeni, A; Bompoint, C; Gomez, A; Brissot, E; Ruggeri, A; Belhocine, R; Mohty, M

    2017-11-01

    Haematopoietic stem cell transplantation-coordinating nurses (HSCT-CNs) play an important role in informing related donors (RDs) and in organising human leucocyte antigen (HLA) tests, pre-donation workup and stem cells collection. Our pilot study aimed to explore French HSCT-CNs' perceptions of RD care issues. Twenty-nine French HSCT adult units were sent a questionnaire on the subject of donation procedures, HSCT-CNs' data and their professional experience of related donation issues. Twenty-two HSCT-CNs returned a completed questionnaire, and 90% of HSCT units were involved to some degree in both patient and donor care. Responses indicated that the provision of information to potential donors prior to HLA tests was insufficient, while donors were given a medical consultation only during the pre-donation workup. Questions were raised about the consent and voluntary status of RDs. None of the HSCT teams organised a post-donation consultation, while 57% provided follow-up by phone or via a questionnaire. Our results draw attention to the conflict of interest experienced by HSCT-CNs when caring simultaneously for patients and donors. The specific psychosocial difficulties associated with becoming an RD are also highlighted. French HSCT-CNs' perceptions of related donation reveal many ethical and clinical problems that have yet to be fully explored. Data on this topic remain scarce, and our pilot study may contribute to the current debate on the organisation of RD care. © 2016 John Wiley & Sons Ltd.

  13. Blood group genotyping: from patient to high-throughput donor screening.

    Science.gov (United States)

    Veldhuisen, B; van der Schoot, C E; de Haas, M

    2009-10-01

    Blood group antigens, present on the cell membrane of red blood cells and platelets, can be defined either serologically or predicted based on the genotypes of genes encoding for blood group antigens. At present, the molecular basis of many antigens of the 30 blood group systems and 17 human platelet antigens is known. In many laboratories, blood group genotyping assays are routinely used for diagnostics in cases where patient red cells cannot be used for serological typing due to the presence of auto-antibodies or after recent transfusions. In addition, DNA genotyping is used to support (un)-expected serological findings. Fetal genotyping is routinely performed when there is a risk of alloimmune-mediated red cell or platelet destruction. In case of patient blood group antigen typing, it is important that a genotyping result is quickly available to support the selection of donor blood, and high-throughput of the genotyping method is not a prerequisite. In addition, genotyping of blood donors will be extremely useful to obtain donor blood with rare phenotypes, for example lacking a high-frequency antigen, and to obtain a fully typed donor database to be used for a better matching between recipient and donor to prevent adverse transfusion reactions. Serological typing of large cohorts of donors is a labour-intensive and expensive exercise and hampered by the lack of sufficient amounts of approved typing reagents for all blood group systems of interest. Currently, high-throughput genotyping based on DNA micro-arrays is a very feasible method to obtain a large pool of well-typed blood donors. Several systems for high-throughput blood group genotyping are developed and will be discussed in this review.

  14. Anti-hepatitis B core antigen testing with detection and characterization of occult hepatitis B virus by an in-house nucleic acid testing among blood donors in Behrampur, Ganjam, Orissa in southeastern India: implications for transfusion

    Directory of Open Access Journals (Sweden)

    Panigrahi Rajesh

    2010-08-01

    Full Text Available Abstract Background Occult hepatitis B virus (HBV infection might transmit viremic units into the public blood supply if only hepatitis B surface antigen (HBsAg testing is used for donor screening. Our aim was to evaluate the prevalence of occult HBV infection among the HBsAg negative/antiHBc positive donations from a highly HIV prevalent region of India. Methods A total of 729 HBsAg negative donor units were included in this study. Surface gene and precore region were amplified by in house nucleic acid test (NAT for detection of occult HBV infection and surface gene was analyzed after direct sequencing. Results A total of 220 (30.1% HBsAg negative donors were antiHBc positive, of them 66 (30% were HBV DNA positive by NAT. HBV DNA positivity among 164 antiHBc only group, was 27.1% and among 40 antiHBs positive group was 30.0%. HBV/D (93.3% was predominant and prevalence of both HBV/C and HBV/A was 3.3%. Single or multiple amino acids substitutions were found in 95% samples. Conclusion Thus, a considerable number of HBV infected donors remain undiagnosed, if only HBsAg is used for screening. Addition of antiHBc testing for donor screening, although will lead to rejection of a large number of donor units, will definitely eliminate HBV infected donations and help in reducing HBV transmission with its potential consequences, especially among the immunocompromised population. The HBV genetic diversity found in this donor population are in accordance with other parts of India.

  15. Anti-hepatitis B core antigen testing with detection and characterization of occult hepatitis B virus by an in-house nucleic acid testing among blood donors in Behrampur, Ganjam, Orissa in southeastern India: implications for transfusion.

    Science.gov (United States)

    Panigrahi, Rajesh; Biswas, Avik; Datta, Sibnarayan; Banerjee, Arup; Chandra, Partha K; Mahapatra, Pradip K; Patnaik, Bharat; Chakrabarti, Sekhar; Chakravarty, Runu

    2010-08-27

    Occult hepatitis B virus (HBV) infection might transmit viremic units into the public blood supply if only hepatitis B surface antigen (HBsAg) testing is used for donor screening. Our aim was to evaluate the prevalence of occult HBV infection among the HBsAg negative/antiHBc positive donations from a highly HIV prevalent region of India. A total of 729 HBsAg negative donor units were included in this study. Surface gene and precore region were amplified by in house nucleic acid test (NAT) for detection of occult HBV infection and surface gene was analyzed after direct sequencing. A total of 220 (30.1%) HBsAg negative donors were antiHBc positive, of them 66 (30%) were HBV DNA positive by NAT. HBV DNA positivity among 164 antiHBc only group, was 27.1% and among 40 antiHBs positive group was 30.0%. HBV/D (93.3%) was predominant and prevalence of both HBV/C and HBV/A was 3.3%. Single or multiple amino acids substitutions were found in 95% samples. Thus, a considerable number of HBV infected donors remain undiagnosed, if only HBsAg is used for screening. Addition of antiHBc testing for donor screening, although will lead to rejection of a large number of donor units, will definitely eliminate HBV infected donations and help in reducing HBV transmission with its potential consequences, especially among the immunocompromised population. The HBV genetic diversity found in this donor population are in accordance with other parts of India.

  16. Safety of blood supply in the Caribbean countries: role of screening blood donors for markers of hepatitis B and C viruses.

    Science.gov (United States)

    Cruz, Jose R; Pérez-Rosales, Maria Dolores; Zicker, Fabio; Schmunis, Gabriel A

    2005-12-01

    Blood transfusions carry risks of untoward reactions, including the transmission of infections, such as hepatitis B and C. Proper blood donor recruitment and selection, and adequate laboratory screening for infectious markers diminish the risk of transfusion-transmitted infections. To estimate the potential risk of acquiring transfusion-transmitted infections by hepatitis B or hepatitis C in 24 Caribbean countries during the period of 1996 to 2003. Official national reports for 1996, 2000-2003 of the yearly number of blood donors, screening coverage, and prevalence of serological markers for infectious diseases were used to estimate the risk of patients receiving an HBV- or HCV-positive unit of blood, and of developing an infection after receiving a positive unit. Estimates of number of infections transmitted through transfusion and number of infections prevented by screening of blood were also obtained. During the period analyzed, HBV screening coverage among blood donors was 100% in all countries with the exception of Grenada (0% in 1996) and Saint Lucia (99.5% in 2002). For HCV, only 10 countries reported universal screening in 1996, while 15 did in 2003. The number of countries that did not screen any units for HCV decreased from 11 in 1996 to five in 2003. In general, high prevalence rates of HBV (10-75 per 1000 donors) and HCV (7-19.3 per 1000 donors) markers were found in the majority of countries. We estimated that 235 infections by HCV (1:12471 donations) and two infections by HBV (1:1465373) were transmitted through transfusion because of lack of screening. On the other hand, screening of blood for transfusion prevented 21 005 HCV and 22 100 HBV infections. Blood donor recruitment and coverage of screening for transfusion-transmitted infections, especially HCV, must be improved in the Caribbean countries.

  17. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  18. 21 CFR 866.2420 - Oxidase screening test for gonorrhea.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oxidase screening test for gonorrhea. 866.2420... screening test for gonorrhea. (a) Identification. An oxidase screening test for gonorrhea is an in vitro... of gonorrhea. (b) Classification. Class III (premarket approval) (transitional device). (c) Date PMA...

  19. Screening of blood donors for chronic Coxiella burnetii infection after large Q fever outbreaks

    NARCIS (Netherlands)

    Slot, Ed; Hogema, Boris M.; Molier, Michel; Zaaijer, Hans L.

    2014-01-01

    The Netherlands experienced major Q fever outbreaks from 2007 through 2009. An increasing number of human chronic Q fever cases has been reported in the affected area. Blood donors unaware of chronic Coxiella burnetii infection might be infectious for transfusion recipients. Local blood donations

  20. 21 CFR 1271.75 - How do I screen a donor?

    Science.gov (United States)

    2010-04-01

    ..., including: (i) Human immunodeficiency virus; (ii) Hepatitis B virus; (iii) Hepatitis C virus; (iv) Human... diseases, including Human T-lymphotropic virus. (c) Donors of reproductive cells or tissue. In addition to... this section; or (2) Any communicable disease risk associated with xenotransplantation. (e) Abbreviated...

  1. Cytomegalovirus disease in a renal transplant recipient: the importance of pre-transplant screening of the donor and recipient

    Directory of Open Access Journals (Sweden)

    Ahmed H Mitwalli

    2013-01-01

    Full Text Available A 16-year-old female patient who was born with a single kidney developed chronic kidney disease during her early childhood due to reflux nephropathy and recurrent urinary tract infection. She progressed to end-stage renal disease (ESRD and was commenced on renal replacement therapy in the form of peritoneal dialysis in May 2011. Subsequently, she underwent living unrelated donor kidney transplantation in China. She was hospitalized soon after returning to Saudi Arabia for management of high-grade fever, shortness of breath, and deterioration of renal function, which was found to be due to cytomegalovirus (CMV disease, proved by kidney biopsy and presence of high level of anti-CMV immunoglobulins. Allograft biopsy showed mature viral particles sized between 120 and 149 nm in the nuclei of the glomerular endothelial cells. The patient was treated with valgancyclovir and specific CMV immunoglobulin, as well as by reducing and even stopping the dose of tacrolimus and mycophenolate. Despite all these measures, her condition continued to deteriorate and she finally died. Our study emphasizes that unrelated renal transplantation, especially if unplanned and improperly prepared, is a very risky procedure that might transfer dangerous diseases and increase the morbidity and mortality of the patients. We strongly stress the need for mandatory and proper screening for CMV carrier status among donors as well as recipients prior to transplantation. Also, a recommendation is made to reject CMV-positive donors.

  2. [Mokken scaling of the Cognitive Screening Test].

    Science.gov (United States)

    Diesfeldt, H F A

    2009-10-01

    The Cognitive Screening Test (CST) is a twenty-item orientation questionnaire in Dutch, that is commonly used to evaluate cognitive impairment. This study applied Mokken Scale Analysis, a non-parametric set of techniques derived from item response theory (IRT), to CST-data of 466 consecutive participants in psychogeriatric day care. The full item set and the standard short version of fourteen items both met the assumptions of the monotone homogeneity model, with scalability coefficient H = 0.39, which is considered weak. In order to select items that would fulfil the assumption of invariant item ordering or the double monotonicity model, the subjects were randomly partitioned into a training set (50% of the sample) and a test set (the remaining half). By means of an automated item selection eleven items were found to measure one latent trait, with H = 0.67 and item H coefficients larger than 0.51. Cross-validation of the item analysis in the remaining half of the subjects gave comparable values (H = 0.66; item H coefficients larger than 0.56). The selected items involve year, place of residence, birth date, the monarch's and prime minister's names, and their predecessors. Applying optimal discriminant analysis (ODA) it was found that the full set of twenty CST items performed best in distinguishing two predefined groups of patients of lower or higher cognitive ability, as established by an independent criterion derived from the Amsterdam Dementia Screening Test. The chance corrected predictive value or prognostic utility was 47.5% for the full item set, 45.2% for the fourteen items of the standard short version of the CST, and 46.1% for the homogeneous, unidimensional set of selected eleven items. The results of the item analysis support the application of the CST in cognitive assessment, and revealed a more reliable 'short' version of the CST than the standard short version (CST14).

  3. Evaluation of the concomitant use of two different EIA tests for HIV screening in blood banks

    Directory of Open Access Journals (Sweden)

    Otani Marcia M.

    2003-01-01

    Full Text Available OBJECTIVE: In 1998, the Brazilian Ministry of Health made it mandatory for all blood banks in the country to screen donated blood for human immunodeficiency virus (HIV concomitantly using two different enzyme immunoassay (EIA tests. Concerned with the best use of available resources, our objective with this study was to evaluate the usefulness of conducting two EIA screening tests instead of just one. METHODS: We analyzed data from 1999 through 2001 obtained by testing 698 191 units of donated blood using two EIA HIV screening tests concomitantly at the Pro-Blood Foundation/Blood Center of São Paulo (Fundação Pró-Sangue/Hemocentro de São Paulo, which is a major blood center in the city of São Paulo, Brazil. All samples reactive in at least one of the two EIA tests were submitted for confirmation by a Western blot (WB test, and the persons who had donated those samples were also asked to return and provide a follow-up sample. RESULTS: Out of the 698 191 blood units that were donated, 2 718 of them (0.4% had to be discarded because they were reactive to at least one of the EIA tests. There were two WB-positive donation samples that were reactive in only one HIV EIA screening test. On their follow-up samples, both donors tested WB-negative. These cases were considered false positive results at screening. Of the 2 718 donors who were asked to return and provide a follow-up sample, 1 576 of them (58% did so. From these 1 576 persons, we found that there were two individuals who had been reactive to only one of the two EIA screening tests and who had also been negative on the WB at screening but who were fully seroconverted on the follow-up sample. We thus estimated that, in comparison to the use of a single EIA screening test, the use of two EIA screening tests would detect only one extra sample out of 410 700 units of blood. CONCLUSIONS: Our data do not support the use of two different, concomitant EIA screening tests for HIV. The great

  4. Electrical and optical spectroscopy for quantitative screening of hepatic steatosis in donor livers

    Energy Technology Data Exchange (ETDEWEB)

    McLaughlin, B L; Wilkinson, T D; Robertson, P A [Engineering Department, University of Cambridge, 9 JJ Thomson Avenue, Cambridge CB3 OFA (United Kingdom); Wells, A C; Watson, C J E [University Department of Surgery, Addenbrooke' s Hospital, Box 202, Level 9, Hills Road, Cambridge CB2 OCQ (United Kingdom); Virtue, S; Vidal-Puig, A, E-mail: mclaugb@gmail.co [Department of Clinical Biochemistry, University of Cambridge, Addenbrooke' s Hospital, Hills Road, Cambridge CB2 2QR (United Kingdom)

    2010-11-21

    Macro-steatosis in deceased donor livers is increasingly prevalent and is associated with poor or non-function of the liver upon reperfusion. Current assessment of the extent of steatosis depends upon the macroscopic assessment of the liver by the surgeon and histological examination, if available. In this paper we demonstrate electrical and optical spectroscopy techniques which quantitatively characterize fatty infiltration in liver tissue. Optical spectroscopy showed a correlation coefficient of 0.85 in humans when referenced to clinical hematoxylin and eosin (H and E) sections in 20 human samples. With further development, an optical probe may provide a comprehensive measure of steatosis across the liver at the time of procurement.

  5. A novel approach to detect test-seeking behaviour in the blood donor population: making the invisible visible.

    Science.gov (United States)

    de Vos, A S; Lieshout-Krikke, R W; Slot, E; Cator, E A; Janssen, M P

    2016-10-01

    Individuals may donate blood in order to determine their infection status after exposure to an increased infection risk. Such test-seeking behaviour decreases transfusion safety. Instances of test seeking are difficult to substantiate as donors are unlikely to admit to such behaviour. However, manifestation in a population of repeat donors may be determined using statistical inference. Test-seeking donors would be highly motivated to donate following infection risk, influencing the timing of their donation. Donation intervals within 2005-2014 of all Dutch blood donors who acquired syphilis (N = 50), HIV (N = 13), HTLV (N = 4) or HCV (N = 2) were compared to donation intervals of uninfected blood donors (N = 7 327 836) using the Anderson-Darling test. We adjusted for length bias as well as for age, gender and donation type of the infected. Additionally, the power of the proposed method was investigated by simulation. Among the Dutch donors who acquired infection, we found only a non-significant overrepresentation of short donation intervals (P = 0·54). However, we show by simulation that both relatively short and long donation intervals among infected donors can reveal test seeking. The power of the method is >90% if among 69 infected donors >35 (51%) are test seeking, or if among 320 infected donors >90 (30%) are test seeking. We show how statistical analysis may be used to reveal the extent of test seeking in repeat blood donor populations. In the Dutch setting, indications for test-seeking behaviour were not statistically significant. This may, however, be due to the low number of infected individuals. © 2016 International Society of Blood Transfusion.

  6. Breast, prostate, and thyroid cancer screening tests and overdiagnosis.

    Science.gov (United States)

    Jung, Minsoo

    The purpose of this study was to examine overdiagnosis and overtreatment related to cancer screening and to review relevant reports and studies. A comprehensive search of peer-reviewed and gray literature was conducted for relevant studies published between January 2000 and December 2015 reporting breast, prostate, and thyroid cancer screening tests and overdiagnosis. This study revealed no dichotomy on where screening would lower risk or cause overdiagnosis and overtreatment. Many screening tests did both, that is, at population level, there were both benefit (decreased disease-specific mortality) and harm (overdiagnosis and overtreatment). Therefore, we need to consider a balanced argument with citations for the potential benefits of screening along with the harms associated with screening. Although the benefits and harms can only be tested through randomized trials, important data from cohort studies, diagnostic accuracy studies, and modeling work can help define the extent of benefits and harms in the population. The health care cycle that prompt patients to undergo periodic screening tests is self-reinforcing. In most developed countries, screening test recommendations encourage periodic testing. Therefore, patients are continuing their screening. It is necessary for patients to become wise consumers of screening tests and make decisions with their physicians regarding further testing and treatments. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Chiral Amine Synthesis Using ω-Transaminases: An Amine Donor that Displaces Equilibria and Enables High-Throughput Screening**

    Science.gov (United States)

    Green, Anthony P; Turner, Nicholas J; O'Reilly, Elaine

    2014-01-01

    The widespread application of ω-transaminases as biocatalysts for chiral amine synthesis has been hampered by fundamental challenges, including unfavorable equilibrium positions and product inhibition. Herein, an efficient process that allows reactions to proceed in high conversion in the absence of by-product removal using only one equivalent of a diamine donor (ortho-xylylenediamine) is reported. This operationally simple method is compatible with the most widely used (R)- and (S)-selective ω-TAs and is particularly suitable for the conversion of substrates with unfavorable equilibrium positions (e.g., 1-indanone). Significantly, spontaneous polymerization of the isoindole by-product generates colored derivatives, providing a high-throughput screening platform to identify desired ω-TA activity. PMID:25138082

  8. Role of signal-to-cut-off ratios of anti-hepatitis C virus antibody by enzyme immunoassays along with ID-NAT for screening of whole blood donors in India

    Directory of Open Access Journals (Sweden)

    Satyam Arora

    2016-01-01

    Full Text Available Background: The use of elevated signal-to-cut off ratios (S/CO as an alternate to further supplemental testing (i.e., RIBA has been included in the guidelines provided by the Centres for Disease Control and Prevention for HCV diagnostic purposes since 2003. With availability of screening by NAT and non availability of RIBA, further confirmation of HCV infection has been possible at the molecular level (RNA. Aims: To study the role of S/CO ratios of anti hepatitis C virus antibody detection by enzyme immunoassays (EIA along with ID-NAT for screening of whole blood donors. Methods: In this study we reviewed the donor screening status for anti HCV from January 2013 to May 2014. All the donations were screened for anti HCV with fourth generation ELISA (BioRad Monolisa Ag-Ab Ultra as well as with ID NAT (Procleix Ultrio. The S/CO ratio of all the anti-HCV reactive samples were analysed for their presence of HCV RNA. Results: On screening 21,115 donors for HCV, 83 donors (0.39% were found reactive on pilot tube and repeat plasma bag testing (S/Co ratio ≥1 by ELISA. 41 donors were HCV RNA reactive with ID-NAT. 4 samples out of 41 were NAT yields and 37 were concordant reactive with ELISA. The S/Co ratio of anti-HCV reactive samples ranged from 0.9-11.1 [mean = 5.1; SD ΁ 2.9] whereas S/Co ratio of anti HCV and NAT reactive samples (concordant positives ranged from 4.1-11.1 [mean 7.3]. In our analysis we found that S/CO ratio of 4 showed positive predictive value (PPV and sensitivity of 100%. Summary/Conclusions: Our study showed that S/CO of 4 for anti HCV on ELISA would have maximum positive predictive value of having donor with HCV RNA. S/CO ratio of 4 is very close to 3.8 which was the CDC guideline. The presence of anti-HCV does not distinguish between current or past infections but a confirmed anti-HCV-positive result indicates the need for counseling and medical evaluation for HCV infection.

  9. Coanda hydro intake screen testing and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Howarth, J.

    2001-07-01

    The objective of this project has been to evaluate the effectiveness, suitability and cost benefit of the Aquashear Coanda effect, maintenance free intake screen for use in small hydro system intakes. (author)

  10. [Blood Test Patterns for Blood Donors after Nucleic Acid Detection in the Blood Center].

    Science.gov (United States)

    Men, Shou-Shan; Lv, Lian-Zhi; Chen, Yuan-Feng; Han, Chun-Hua; Liu, Hong-Yu; Yan, Yan

    2017-12-01

    To investigate the blood test patterns for blood donors after nucleic acid detection in blood center. The collected blood samples after voluntary blood donors first were detected by conventional ELISA, then 31981 negative samples were detected via HBV/HCV/HIV combined nucleic acid test of 6 mixed samples(22716 cases) or single samples(9265 cases) by means of Roche cobas s201 instrument. The combined detection method as follows: the blood samples were assayed by conventional nucleic acid test of 6 mixed samples, at same time, 6 mixed samples were treated with polyethylene glycol precipitation method to concentrate the virus, then the nucleic acid test of blood samples was performed; the single detection method as follows: firstly the conventional nucleic acid test of single sample was performed, then the positive reactive samples after re-examination were 6-fold diluted to simulate the nucleic acid test of 6-mixed samples. The positive rate of positive samples detected by combined nucleic acid test, positive samples detected by nucleic acid test of mixed virus concentration and positive samples detected by single nucleic acid test was statistically analyzed. In addition, for HBV + persons the serological test yet should be performed. In 22 716 samples detected by nucleic acid test of 6 mixed samples (MP-6-NAT) , 9 cases were HBV + (0.40‰, 9/22716); at same time, the detection of same samples by nucleic acid test of mixed sample virus concentration showed 29 cases of HBV + (1.28‰, 29/22716). In 9265 samples detected by single nucleic acid test(ID-NAT) 12 cases showed HBV + (1.30‰, 12/9265), meanwhile the detection of these 12 samples with HBV + by 6-fold dilution for virus concentration found only 4 samples with HBV + . In serological qualified samples, ID-NAT unqualified rate was 1.28‰, which was higher than that of MP-6-NAT(0.4‰) (χ 2 =8.11, P0.05). In 41 samples with HBsAg - HBV DNA + detected by ELISA, 36 samples were confirmed to be occult HBV

  11. Screening for gestational diabetes: examining a breakfast meal test ...

    African Journals Online (AJOL)

    Objective: This study was performed to analyse the carbohydrate quantity of the non-standardised breakfast meal test consumed as part of a screening test for gestational diabetes. Design: A prospective descriptive design was utilised. Setting: Screening for gestational diabetes was performed in the High-Risk Antenatal ...

  12. Direct-to-consumer DNA testing: the fallout for individuals and their families unexpectedly learning of their donor conception origins.

    Science.gov (United States)

    Crawshaw, Marilyn

    2017-07-11

    Increasing numbers of donor-conceived individuals (and/or parents) are seeking individuals genetically related through donor conception. One route is through 'direct-to-consumer' (DTC) DNA testing, prompting calls for fertility services to alert donors and prospective parents to the increasing unsustainability of anonymity and secrecy. The complexity of interpreting DNA results in this context has also been discussed, including their lack of absolute certainty, as has the need for professional and peer support. This commentary highlights a different 'threat', from individuals learning of their donor-conception origins through the use of such tests by themselves or relatives for such purposes as genealogy or health checks. It illustrates the personal complexities faced by three older women and their families on learning not only of their genetic relationship to each other but also to 15 more donor-related siblings. DTC DNA services are a growing feature of modern life. This commentary raises ethical questions about their responsibilities towards those inadvertently learning of donor conception origins and the responsibilities of fertility services to inform prospective parents and donors of this new phenomenon. Considerations of how and when parents should tell their children of their donor-conception origins here instead become how and when children should inform their parents.

  13. Cervical Cancer Screening with HPV Test

    Centers for Disease Control (CDC) Podcasts

    Dr. Stewart Massad, a professor in the Division of Gynecologic Oncology at Washington University in Saint Louis and a board member of the American Society for Colposcopy and Cervical Cancer Prevention (ASCCP), talks about cotesting with human papillomavirus (HPV) as part of a cervical cancer screening program.

  14. Management of blood donors and blood donations from individuals found to have a positive direct antiglobulin test.

    Science.gov (United States)

    Hannon, Judith L

    2012-04-01

    The medical literature is replete with articles addressing the diagnosis and management of patients with a positive direct antiglobulin test (DAT). However, there is scant information addressing the management of blood donors and blood donations found to have a positive DAT. Practices vary considerably between countries and blood suppliers within countries, and there is no standardized approach to the management of these blood donors or the blood products prepared from their donations. Recent evidence from Israel suggests that the finding of a positive DAT in a blood donor may not be as benign as previously thought. Therefore, it may be prudent for blood collection agencies to periodically reexamine their approach to the management of blood donors with a positive DAT and their donations. This article reviews the available literature and explores options for the management of DAT-positive blood donors and their blood donations. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Cervical Cancer Screening with HPV Test

    Centers for Disease Control (CDC) Podcasts

    2009-10-15

    Dr. Stewart Massad, a professor in the Division of Gynecologic Oncology at Washington University in Saint Louis and a board member of the American Society for Colposcopy and Cervical Cancer Prevention (ASCCP), talks about cotesting with human papillomavirus (HPV) as part of a cervical cancer screening program.  Created: 10/15/2009 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP), Division of Cancer Prevention and Control (DCPC).   Date Released: 6/9/2010.

  16. Parental versus non-parental-directed donation: an 11-year experience of infectious disease testing at a pediatric tertiary care blood donor center.

    Science.gov (United States)

    Jacquot, Cyril; Seo, Andrew; Miller, Peter M; Lezama, Niara; Criss, Valli R; Colvin, Camilla; Luban, Naomi L C; Wong, Edward C C

    2017-11-01

    Directed donation is associated with a higher prevalence of donations that are positive for infectious disease markers; however, little is known about the positive rates among parental-directed, non-parental-directed, and allogeneic donations. We reviewed blood-collection records from January 1997 through December 2008, including infectious disease results, among parental, non-parental, and community donations. Infectious disease rates were compared by Mann-Whitney U test. In total, 1532 parental, 4910 non-parental, and 17,423 community donations were examined. Among parental donors, the median rate of positive infectious disease testing was 8.66% (interquartile range (IQR), 4.49%) for first-time donors and 1.26% (IQR, 5.86%) for repeat donors; among non-parental donors, the rate was 1.09% (IQR, 0.98%) for first-time donors and 0% (IQR, 0.83%) for repeat donors; and, among community donors, the rate was 2.95% (IQR, 1.50%) for first-time donors and 0.45% (IQR, 0.82%) for repeat donors. The mean rate of positive infectious disease testing for first-time parental donors was significantly higher (7.63%), whereas all repeat donors had similar rates. However, the rate of positive infectious disease testing among first-time non-parental donors was significantly lower than that in the other groups, especially for the period from 2001 through 2008. First-time non-parental and community donors had significantly higher infectious disease risk than the respective repeat donors. First-time parental donors had the highest rates of positive infectious disease testing. We suggest that first-time parental blood donation should be discouraged. Repeat community donors or first-time non-parental donors provide a safer alternative. These findings can foster better patient education, donor selection, and possibly a reduced risk of infectious disease. © 2017 AABB.

  17. Pre-screening Discussions and Prostate-Specific Antigen Testing for Prostate Cancer Screening.

    Science.gov (United States)

    Li, Jun; Zhao, Guixiang; Hall, Ingrid J

    2015-08-01

    For many men, the net benefit of prostate cancer screening with prostate-specific antigen (PSA) tests may be small. Many major medical organizations have issued recommendations for prostate cancer screening, stressing the need for shared decision making before ordering a test. The purpose of this study is to better understand associations between discussions about benefits and harms of PSA testing and uptake of the test among men aged ≥40 years. Associations between pre-screening discussions and PSA testing were examined using self-reported data from the 2012 Behavioral Risk Factor Surveillance System. Unadjusted prevalence of PSA testing was estimated and AORs were calculated using logistic regression in 2014. The multivariate analysis showed that men who had ever discussed advantages of PSA testing only or discussed both advantages and disadvantages were more likely, respectively, to report having had a test within the past year than men who had no discussions (ptesting with their healthcare providers were more likely (AOR=2.75, 95% CI=2.00, 3.79) to report getting tested than men who had no discussions. Discussions of the benefits or harms of PSA testing are positively associated with increased uptake of the test. Given the conflicting recommendations for prostate cancer screening and increasing importance of shared decision making, this study points to the need for understanding how pre-screening discussions are being conducted in clinical practice and the role played by patients' values and preferences in decisions about PSA testing. Published by Elsevier Inc.

  18. False-positive Human Papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Lynge, Elsebeth

    2011-01-01

    Based on data from randomised controlled trials (RCT) on primary cervical screening, it has been reported that the problem of more frequent false-positive tests in Human Papillomavirus (HPV) DNA screening compared to cytology could be overcome. However, these reports predominantly operated...

  19. Solubility tests and the peripheral blood film method for screening ...

    African Journals Online (AJOL)

    Objective. To determine the cost benefit of screening for sicklecell disease among infants at district health centres in Uganda using sickling, solubility tests and the peripheral blood film method. Methods. Pilot screening services were established at district health centres. Cost benefit analysis (CBA) was performed in four ...

  20. Screening for suppression in young children: the Polaroid Suppression test

    NARCIS (Netherlands)

    Pott, J.W.R.; Oosterveen, DK; Van Hof-van Duin, J

    1998-01-01

    Background: Assessment of monocular visual impairment during screening of young children is often hampered by lack of cooperation. Because strabismus, amblyopia, or anisometropia may lead to monocular suppression during binocular viewing conditions, a test was developed to screen far suppression in

  1. Testing the Untestable: A Vision Screening Program for Exceptional Children.

    Science.gov (United States)

    Bishop, Virginia E.; Godolphin, Vivienne

    Based on a longitudinal study of vision screening techniques for handicapped children at the Chester County (Pennsylvania) Child Development Center, the paper reports on the development of a battery of effective vision screening methods for children with low functioning handicapped children. Specific tests are described, including the Sheridan…

  2. Physician-patient discussions of controversial cancer screening tests.

    Science.gov (United States)

    Dunn, A S; Shridharani, K V; Lou, W; Bernstein, J; Horowitz, C R

    2001-02-01

    Screening mammography for younger women and prostate-specific antigen (PSA) measurement have controversial benefits and known potential adverse consequences. While providing informed consent and eliciting patient preference have been advocated for these tests, little is known about how often these discussions take place or about barriers to these discussions. We administered a survey to medical house staff and attending physicians practicing primary care. The survey examined physicians' likelihood of discussing screening mammography and PSA testing, and factors influencing the frequency and quality of these discussions. For the three scenarios, 16% to 34% of physicians stated that they do not discuss the screening tests. The likelihood of having a discussion was significantly associated with house staff physicians' belief that PSA screening is advantageous; house staff and attending physicians' intention to order a PSA test, and attending physicians' intention to order a mammogram; and a controversial indication for screening. The most commonly identified barriers to discussions were lack of time, the complexity of the topic, and a language barrier. Physicians report they often do not discuss cancer screening tests with their patients. Our finding that physicians' beliefs and intention to order the tests, and extraneous factors such as time constraints and a language barrier, are associated with discussions indicates that some patients may be inappropriately denied the opportunity to choose whether to screen for breast and prostate cancer.

  3. Physician–Patient Discussions of Controversial Cancer Screening Tests

    Science.gov (United States)

    Dunn, Andrew S.; Shridharani, Kanan V.; Lou, Wendy; Bernstein, Jeffrey; Horowitz, Carol R.

    2016-01-01

    Background Screening mammography for younger women and prostate-specific antigen (PSA) measurement have controversial benefits and known potential adverse consequences. While providing informed consent and eliciting patient preference have been advocated for these tests, little is known about how often these discussions take place or about barriers to these discussions. Methods We administered a survey to medical house staff and attending physicians practicing primary care. The survey examined physicians’ likelihood of discussing screening mammography and PSA testing, and factors influencing the frequency and quality of these discussions. Results For the three scenarios, 16% to 34% of physicians stated that they do not discuss the screening tests. The likelihood of having a discussion was significantly associated with house staff physicians’ belief that PSA screening is advantageous; house staff and attending physicians’ intention to order a PSA test, and attending physicians’ intention to order a mammogram; and a controversial indication for screening. The most commonly identified barriers to discussions were lack of time, the complexity of the topic, and a language barrier. Conclusions Physicians report they often do not discuss cancer screening tests with their patients. Our finding that physicians’ beliefs and intention to order the tests, and extraneous factors such as time constraints and a language barrier, are associated with discussions indicates that some patients may be inappropriately denied the opportunity to choose whether to screen for breast and prostate cancer. PMID:11165455

  4. Low transfusion transmission of hepatitis E among 25,637 single-donation, nucleic acid-tested blood donors

    DEFF Research Database (Denmark)

    Harritshøj, Lene H.; Holm, Dorte K.; Sækmose, Susanne G.

    2016-01-01

    nucleic acid test with a 95% detection probability of 7.9 IU/mL. HEV-positive samples were quantified by real-time polymerase chain reaction and genotyped. Transmission was evaluated among recipients of HEV RNA-positive blood components. Phylogenetic analyses compared HEV sequences from blood donors......, symptomatic patients, and swine. RESULTS: Eleven donations (0.04%) were confirmed as positive for HEV RNA (median HEV RNA level, 13 IU/mL). Two donations were successfully genotyped as HEV-gt-3. Only one donor had a travel history outside Europe. Nine of 11 donors were male, but the gender ratio...

  5. Chiral amine synthesis using ω-transaminases: an amine donor that displaces equilibria and enables high-throughput screening.

    Science.gov (United States)

    Green, Anthony P; Turner, Nicholas J; O'Reilly, Elaine

    2014-09-26

    The widespread application of ω-transaminases as biocatalysts for chiral amine synthesis has been hampered by fundamental challenges, including unfavorable equilibrium positions and product inhibition. Herein, an efficient process that allows reactions to proceed in high conversion in the absence of by-product removal using only one equivalent of a diamine donor (ortho-xylylenediamine) is reported. This operationally simple method is compatible with the most widely used (R)- and (S)-selective ω-TAs and is particularly suitable for the conversion of substrates with unfavorable equilibrium positions (e.g., 1-indanone). Significantly, spontaneous polymerization of the isoindole by-product generates colored derivatives, providing a high-throughput screening platform to identify desired ω-TA activity. © 2014 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

  6. 42 CFR 410.18 - Diabetes screening tests.

    Science.gov (United States)

    2010-10-01

    ... screening tests. (a) Definitions. For purposes of this section, the following definitions apply: Diabetes... receive the benefit: (1) Hypertension. (2) Dyslipidemia. (3) Obesity, defined as a body mass index greater...

  7. Indicators for monitoring screening programs with primary HPV test.

    Science.gov (United States)

    Zorzi, Manuel; Giorgi Rossi, Paolo

    2017-01-01

    following scientific evidence produced in numerous studies, as well as national and international guidelines, organized cervical cancer screening programs in Italy have gradually introduced the HPV test as primary screening test, replacing cytology. As public health interventions, screening programs must ensure equity, improvement in quality of life, and adequate information for the population involved with regards to benefits and possible risks; therefore, it is essential for quality to be constantly checked at every phase of the project.The Italian Cervical Screening Group (Gruppo Italiano per lo Screening Cervicale, GISCi) has written a handbook for the calculation and interpretation of cervical screening program monitoring indicators that take into account the new protocol based on primary HPV test with cytology triage. based on the European guidelines and Italian recommendations on primary HPVbased screening, the working group, which includes professionals from all the fields involved in cervical screening, identified the essential points needed to monitor the screening process, the accuracy of individual tests, and early outcomes, defining a specific indicator for each aspect. The indicators were grouped as follows: baseline indicators, indicators for test repeat after one year, cumulative indicators, and waiting times. For every indicator, the source of data, calculation formula, any standards or critical thresholds, and interpretation were defined. The standards are based on the results of NTCC trials or Italian pilot studies. the main indicators proposed for the organization are the following: number of invitations, compliance with first invitation, with one-year test repeat and with colposcopy; for test and process accuracy, a cohort approach was utilised, where indicators are based on women who must be followed for at least one year, so as to integrate the results obtained after the first HPV test with the outcome of the test's repetition after one year

  8. Possibility of using combined treatment of processing and ionizing radiation to eliminate contaminated viruses from non-screened donor of tissue allografts

    International Nuclear Information System (INIS)

    Nazly Hilmy; Paramita Pandansari

    2008-01-01

    Full text: New emerging and re- emerging infectious diseases caused by viruses are outbreak and re- outbreak around the world. Most of the viruses come from animals ( zoonoses) and jump to human beings ( host jumping ) such as corona virus ( SARS), HIV, bird flu/ Avian flu H5N1, hepatitis viruses, Dengue fever virus, West Nile virus/WNV, Hantavirus, Marburg haemorrhagic fever virus, Hendra virus, Nipah virus etc. Transmission of those diseases through transplantation of contaminated tissue allograft to recipient can happened if the donor could not be screened properly. The donor can be well screened from some of those viruses such as HIV, hepatitis viruses and WNV. Processing of tissue allografts by pasteurization, washing and soaking in H 2 O 2 and soap can eliminate contaminated viruses to a certain amount, have been reported by several authors. Viruses are very small microbes, they have DNA/RNA, resistant to radiation but to a certain degree they can be well eliminated by radiation. Their D10 - values vary from 4 to 13 kGy. This paper discribes briefly the possibility of using combined treatment of processing, lyophilization and sterilisation by radiation to overcome problems of non screened donor from some contaminated viruses. (Author)

  9. Do doctors understand the test characteristics of lung cancer screening?

    Science.gov (United States)

    Schmidt, Richard; Breyer, Marie; Breyer-Kohansal, Robab; Urban, Matthias; Funk, Georg-Christian

    2018-04-01

    Screening for lung cancer with a low-dose computed tomography (CT) scan is estimated to prevent 3 deaths per 1000 individuals at high risk; however, false positive results and radiation exposure are relevant harms and deserve careful consideration. Screening candidates can only make an autonomous decision if doctors correctly inform them of the pros and cons of the method; therefore, this study aimed to evaluate whether doctors understand the test characteristics of lung cancer screening. In a randomized trial 556 doctors (members of the Austrian Respiratory Society) were invited to answer questions regarding lung cancer screening based on online case vignettes. Half of the participants were randomized to the group 'solutions provided' and received the correct solutions in advance. The group 'solutions withheld' had to rely on prior knowledge or estimates. The primary endpoint was the between-group difference in the estimated number of deaths preventable by screening. Secondary endpoints were the between-group differences in the prevalence of lung cancer, prevalence of a positive screening results, sensitivity, specificity, positive predictive value, and false negative rate. Estimations were also compared with current data from the literature. The response rate was 29% in both groups. The reduction in the number of deaths due to screening was overestimated six-fold (95% confidence interval CI: 4-8) compared with the actual data, and there was no effect of group allocation. Providing the correct solutions to doctors had no systematic effect on their answers. Doctors poorly understand the test characteristics of lung cancer screening. Providing the correct solutions in advance did not improve the answers. Continuing education regarding lung cancer screening and the interpretation of test characteristics may be a simple remedy. Clinical trial registered with www.clinicaltrials.gov (NCT02542332).

  10. Reiter haemagglutination test: a screening test for syphilis.

    OpenAIRE

    Al-Qudah, A A; Mostratos, A

    1982-01-01

    Using an ultrasonicate of the Reiter treponeme as antigen the Reiter haemagglutination test (RHA) was evaluated as a serological test for syphilis. Comparison of the results of the cardiolipin Wassermann reaction, Reiter protein complement-fixation test, the fluorescent treponemal antibody-absorbed (FTA-ABS) test, the Treponema pallidum haemagglutination test (TPHA) (at dilutions of 1/16 and 1/80), and the Venereal Disease Research Laboratory test with those of the RHA showed that the RHA was...

  11. The use of screening tests in spacecraft lubricant evaluation

    Science.gov (United States)

    Kalogeras, Chris; Hilton, Mike; Carre, David; Didziulis, Stephen; Fleischauer, Paul

    1993-01-01

    A lubricant screening test fixture has been devised in order to satisfy the need to obtain lubricant performance data in a timely manner. This fixture has been used to perform short-term tests on potential lubricants for several spacecraft applications. The results of these tests have saved time by producing qualitative performance rankings of lubricant selections prior to life testing. To date, this test fixture has been used to test lubricants for 3 particular applications. The qualitative results from these tests have been verified by life test results and have provided insight into the function of various anti-wear additives.

  12. [Comparison of eight screening tests for ant-HCV antibody].

    Science.gov (United States)

    Deguchi, Matsuo; Kagita, Masanori; Yamashita, Naoko; Nakano, Takasi; Tahara, Kazuko; Asari, Seishi; Iwatani, Yoshinori

    2002-09-01

    We compared eight HCV screening tests for detection of anti-HCV antibody; Ortho Quick Chaser HCV Ab (QC), Ortho HCV Ab ELISA III (ELISA), Ortho HVC Ab PA test III (PA), Lumipulse II Ortho HCV (LUMI), IMx HCV.DAINAPACKII (IMx), ARCHITECT HCV (ARCH), Immucheck.F-HCV C50 Ab (Immu), RANREAM HCV Ab Ex II (RAN). Sera from six hundred patients were examined by these eight screening tests. The positive rates of the eight screening tests were from 9.0% to 13.2%. Forty-five sera showed discrepant results between the eight screening tests, and about half of them showed weak positive reaction and/or false positive. Twenty-five of the forty-five sera were negative for ant-HCV antibody in the CHIRON RIBA III confirmatory test, and forty-four of them were negative for HCV-RNA in the PCR method. The agreement rates between the two reagents were from 95.5% to 99.2%, but were not always high between the two reagents that used similar antigen. The specificities and sensitivities evaluated by using the RIBA III confirmatory test were excellent in ELISA, LUMI, IMx, ARCH and Immu. Three BBI seroconversion panels were used to compare the positive readings in the initial stage of HCV infection by eight screening tests. ELISA and ARCH showed the earliest positive readings, and then IMx, LUMI = RAN, PA, QC and Immu in this order. These findings indicate that ELISA and ARCH were the most excellent in the sensitivity, specificity and early diagnosis of HCV infection. However, we must pay attention to the weak positive reaction in the screening tests, because there is a possibility of "false positive".

  13. Screening mammography interpretation test: more frequent mistakes

    International Nuclear Information System (INIS)

    Gozzi, Gino; Ganzetti, Alessandra; Martinoli, Carlo; Bacigalupo, Lorenzo; Bodini, Maria; Fiorentino, Carla; Marini, Ugo Paolo; Santini, Dolores

    2005-01-01

    Purpose: To present the mammographic cases most commonly misinterpreted by the participants in the mammography self-test proposed by the Italian Society of Medical Radiology (SIRM) National Congress in Rimini, Italy, 2002, by analysing the findings responsible for errors, suggesting reasons for the errors, and assessing possible inadequacies in the format of the test. Materials and methods: The self-test was performed on the mammograms of 160 cases (32 positive and 128 negative for cancer as confirmed by histology). The mammograms had been taken in the four standard projections and placed on four multi-panel diaphanoscopes, each displaying a set of 40 cases comprising benign and malignant cases in equal proportions. The participants were given pre-printed forms on which to note down their diagnostic judgement. We evaluated a total of 134 fully-completed forms. Among these, we identified the 23 cases most frequently misread by over 15 participants in percentages varying between 40-90%. Of these cases, 10 were malignancies and 13 were negative mammograms. On review, we also assessed the diagnostic contribution of complementary investigations (not available the participants). The 134 fully-completed forms (all of the 40 cases) yielded a total of 5360 responses, 1180 of which (22.01%) were incorrect. Of these 823 out of the 4288 cases expected to be negative (19.2%) were false positive, and 357 out of the 1072 cases expected to be positive (33.3%) were false negative. As regards the 23 most frequently misread cases, these were 10/32 (31.25%) mammograms positive for malignancy and 13/128 (10.15%) negative mammograms or mammograms showing benign disease. The 10 malignancies included 7 infiltrating ductal carcinomas, 1 infiltrating cribriform carcinoma, 1 infiltrating tubular carcinoma, and 1 carcinoma in situ. The 13 cases of benign disease - as established by histology or long-term follow-up - mistaken for malignancies by the test participants were fibrocystic breast

  14. A novel approach to detect test-seeking behaviour in the blood donor population : making the invisible visible

    NARCIS (Netherlands)

    de Vos, A. S.; Lieshout-Krikke, R. W.; Slot, E.; Cator, E. A.; Janssen, M. P.

    2016-01-01

    Background and Objectives: Individuals may donate blood in order to determine their infection status after exposure to an increased infection risk. Such test-seeking behaviour decreases transfusion safety. Instances of test seeking are difficult to substantiate as donors are unlikely to admit to

  15. Evaluation of screening tests for colorectal cancer.

    Science.gov (United States)

    Bolt, R J

    1980-12-01

    The following guidelines are proposed for the asymptomatic patient representing for routine examination. Instruct the patient to eat All Bran cereal or a similar product for breakfast for three consecutive days prior to the day of appointment. At the time of appointment the stool obtained from rectal examination or from a spontaneous bowel movement is checked for occult blood using the guaiac method. If the findings are negative, no further tests are recommended. If positive, the patient is given complete dietary instructions in a non-meat, high-residue diet with avoidance of beets, horseradish, vitamins, or aspirin-containing compounds. The patient is then given six Hemoccult or Quikcult slides and is instructed to prepare two fecal slides from each stool specimen daily for three days. If these are all negative when tested, no further studies are necessary. If one or more are positive, however, sigmoidoscopic examination and colon and upper gastrointestinal radiography should be carried out in that order. Evidence that early lesions (Duke A or B) are detected and the cure rate improved with this procedure is quite convincing.

  16. The use of screening tests in aviation medicine

    International Nuclear Information System (INIS)

    Ruge, A.

    2000-01-01

    Pilots have to submit themselves in regular intervals to medical examinations in order to avoid a sudden incapacitation that could endanger flight safety. In Germany these examinations include screening tests to detect an illness in an early phase and to guide the pilot to keep up his/her health. European Joint Aviation Requirements have no provisions for screening tests. Under Council Directive 96/29/EURATOM flight crews in Germany will have to undergo special medical radiation protection examinations. The introduction of any screening tests that give information about individual reactions to cosmic radiation exposure are very unlikely if results are not kept confidential, as this would limit the choice of profession. Flight crews should be made aware of these tests. (orig.) [de

  17. Screening for Specific Language Impairment in Preschool Children: Evaluating a Screening Procedure Including the Token Test

    Science.gov (United States)

    Willinger, Ulrike; Schmoeger, Michaela; Deckert, Matthias; Eisenwort, Brigitte; Loader, Benjamin; Hofmair, Annemarie; Auff, Eduard

    2017-01-01

    Specific language impairment (SLI) comprises impairments in receptive and/or expressive language. Aim of this study was to evaluate a screening for SLI. 61 children with SLI (SLI-children, age-range 4-6 years) and 61 matched typically developing controls were tested for receptive language ability (Token Test-TT) and for intelligence (Wechsler…

  18. Diagnostic value of serologic tests in celiac screening

    Directory of Open Access Journals (Sweden)

    Hosein Saneian

    2012-01-01

    Conclusions: According to our study results, there is no correlation between gastrointestinal symptoms such as vomiting diarrhea, anorexia, bulimia, and failure to thrive (FFT with celiac. TTG was the best screening test method to diagnose celiac disease and other tests such as AGA and EMA do not have high diagnostic value.

  19. Comparison of a new digital KM screen test with conventional Hess and Lees screen tests in the mapping of ocular deviations.

    Science.gov (United States)

    Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin

    2018-05-28

    To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  20. Cognitive Screening Tests Versus Comprehensive Neuropsychological Test Batteries: A National Academy of Neuropsychology Education Paper†.

    Science.gov (United States)

    Roebuck-Spencer, Tresa M; Glen, Tannahill; Puente, Antonio E; Denney, Robert L; Ruff, Ronald M; Hostetter, Gayle; Bianchini, Kevin J

    2017-06-01

    The American Medical Association Current Procedural Panel developed a new billing code making behavioral health screening a reimbursable healthcare service. The use of computerized testing as a means for cognitive screening and brief cognitive testing is increasing at a rapid rate. The purpose of this education paper is to provide information to clinicians, healthcare administrators, and policy developers about the purpose, strengths, and limitations of cognitive screening tests versus comprehensive neuropsychological evaluations. Screening tests are generally brief and narrow in scope, they can be administered during a routine clinical visit, and they can be helpful for identifying individuals in need of more comprehensive assessment. Some screening tests can also be helpful for monitoring treatment outcomes. Comprehensive neuropsychological assessments are multidimensional in nature and used for purposes such as identifying primary and secondary diagnoses, determining the nature  and severity of a person's cognitive difficulties, determining functional limitations, and planning treatment and rehabilitation. Cognitive screening tests are expected to play an increasingly important role in identifying individuals with cognitive impairment and in determining which individuals should be referred for further neuropsychological assessment. However, limitations of existing cognitive screening tests are present and cognitive screening tests should not be used as a replacement for comprehensive neuropsychological testing. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Test plan for Tank 241-AW-101 solubility screening tests

    International Nuclear Information System (INIS)

    Person, J.C.

    1998-01-01

    Tank 241-AW-101 (101-AW) has been identified as one of the early tanks to be for retrieved for low level waste pretreatment and immobilization and retrieval of the tank waste may require dilution. This test is to determine the effects of dilution on the mass of solids and their composition. This test plan gives test instructions, example data sheets, a waste compatibility review, and a waste stream fact sheet. This test Plan is similar to tests on tanks 241-AN-102 (Person 1998a) and 241-AN-107 (Person 1998 b). The 101-AW tests will be done with composites of liquid and solids from grab samples that were taken in 1998 (Benar 1998). Future revisions of the Tank Sampling and Analysis Plan (Benar 1998) may change the details of the work performed under this test plan

  2. Human papillomavirus testing and genotyping in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Lynge, Elsebeth; Bonde, Jesper

    2011-01-01

    the incidence of cervical cancer, but has a low sensitivity for high-grade cervical intraepithelial neoplasia (CIN) and requires frequent testing. Several HPV tests have become available commercially. They appear to be more sensitive for high-grade CIN, and may further reduce the incidence of cervical cancer......Mass vaccination against human papillomavirus (HPV) genotypes 16 and 18 will, in the long term, reduce the incidence of cervical cancer, but screening will remain an important cancer control measure in both vaccinated and unvaccinated women. Since the 1960s, cytology screening has helped to reduce...

  3. Viremic blood donor found by a rapid screening method in a season of high human parvovirus B19 activity in Niterói, Rio de Janeiro, Brazil

    Directory of Open Access Journals (Sweden)

    Sérgio Setúbal

    2004-02-01

    Full Text Available Erythrovirus B19 infection is usually benign but may have serious consequences in patients with hemolytic anemia (transient aplastic crisis, immunodeficiency (in whom persistent infection can lead to chronic bone marrow failure with anemia, or who are in the first or second trimester of gestation (spontaneous abortion, hydrops fetalis, and fetal death. Being non-enveloped, B19 resists most inactivation methods and can be transmitted by transfusion. B19 is difficult to cultivate and native virus is usually obtained from viremic blood. As specific antibodies may be absent, and there is no reliable immunological method for antigen detection, hybridization or polymerase chain reaction are needed for detecting viremia. A rapid method, gel hemagglutination (Diamed ID-Parvovirus B19 Antigen Test, can disclose highly viremic donations, whose elimination lessens the viral burden in pooled blood products and may even render them non-infectious. In order to obtain native antigen and to determine the frequency of viremic donors, we applied this test to blood donors in a period of high viral activity in our community. Positive or indeterminate results were re-tested by dot-blot hybridization. We tested 472 donors in 1998 and 831 ones in 1999. One viremic donor was found in 1999. We suggest that in periods of high community viral activity the gel hemagglutination test may be useful in avoiding highly viremic blood being added to plasma pools or directly transfused to patients under risk.

  4. Breast Milk and Hair Testing to Detect Illegal Drugs, Nicotine, and Caffeine in Donors to a Human Milk Bank.

    Science.gov (United States)

    Escuder-Vieco, Diana; Garcia-Algar, Óscar; Joya, Xavier; Marchei, Emilia; Pichini, Simona; Pacifici, Roberta; Pallás-Alonso, Carmen Rosa

    2016-08-01

    The use of illegal drugs and tobacco is an exclusion criteria for accepting a nursing mother as a milk donor. The detection window for human milk testing is typically a few hours. Hair testing has been considered the gold standard to assess chronic exposure to these toxic substances. The aim of this study was to determine the levels of illegal drugs, nicotine, and caffeine in breast milk and hair samples from donors to assess whether these substances were being used during the donation period and the months leading up to it. Thirty-six samples of hair and breast milk were obtained from 36 donors. The tests performed identified nicotine, caffeine, morphine, cocaine, cannabis, amphetamines, codeine, methadone, and other substances derived therefrom. No illegal drugs were found in any of the samples analyzed. Nicotine and cotinine were found in 33.3% (12/36) of all hair samples. Among these 12 samples, 10 had cotinine concentrations consistent with cutoff values for unexposed nonsmokers, 1 had concentrations consistent with cutoff values for passive smokers, and 1 had concentrations consistent with cutoff values for active smokers. Caffeine was found in 77.7% of the hair samples and in 50% of the donor milk samples. The correlation for caffeine between donor milk and hair samples was r = 0.288, P = .0881. Donors do not use illegal drugs during either the donation period or the months leading up to it. They are occasionally exposed to tobacco smoke and almost all of them consume caffeine. © The Author(s) 2016.

  5. Alkaline phosphatase as a screening test for osteomalacia.

    Science.gov (United States)

    Chinoy, Muhammad Amin; Javed, Muhammad Imran; Khan, Alamzeb; Sadruddin, Nooruddin

    2011-01-01

    Vitamin D deficiency remains common in children and adults in Pakistan despite adequate sunlight exposure. Diagnosis in adults is usually delayed and is made following pathological fractures that result in significant morbidity. The objective of this study was to see whether Serum Alkaline Phosphatase levels could be used as a screening test for osteomalacia. The Study was conducted at Fatima Hospital, Baqai Medical University, Gadap, Karachi, between July 2002 and June 2005. Serum calcium levels are commonly used to screen patients suspected of osteomalacia, and raised serum alkaline phosphatase (SALP) is considered a diagnostic finding. We used SALP to screen patients who presented with back or non-specific aches and pain of more than six months duration. Three hundred thirty-four (334) patients were screened of which 116 (35%) had raised SALP. Osteomalacia was diagnosed in 92 (79.3%) of these 116 either by plain radiographs, bone biopsy or isotope bone scan. Fifty-four (53.4%) of the 101 cases had a normal level of serum calcium. Osteomalacia is likely to be missed if only serum calcium is used to screen patients. Serum Alkaline Phosphate should be used as the preferred method for screening these patients.

  6. Screening for Drug Abuse Among College Students: Modification of the Michigan Alcoholism Screening Test

    Science.gov (United States)

    Cannell, M. Barry; Favazza, Armando R.

    1978-01-01

    Modified version of the Michigan Alcoholism Screening Test was anonymously given to 245 college students on two Midwestern university campuses. Cutoff score for suspected drug abuse was set at five points. The percent of students scoring five or more points was 25 and 22 from campuses A and B respectively. (Author)

  7. Embryotoxicity of Mirtazapine: a study using Chick Embryotoxicity Screening Test

    Czech Academy of Sciences Publication Activity Database

    Maňáková, E.; Hubičková, L.; Košťálová, J.; Zemanová, Zdeňka

    2010-01-01

    Roč. 31, Suppl.2 (2010), s. 8-10 ISSN 0172-780X Institutional research plan: CEZ:AV0Z50110509 Keywords : embryo toxicity * screening test * mirtazapine Subject RIV: EA - Cell Biology Impact factor: 1.621, year: 2010

  8. Validation of the Hwalek-Sengstock Elder Abuse Screening Test.

    Science.gov (United States)

    Neale, Anne Victoria; And Others

    Elder abuse is recognized as an under-detected and under-reported social problem. Difficulties in detecting elder abuse are compounded by the lack of a standardized, psychometrically valid instrument for case finding. The development of the Hwalek-Sengstock Elder Abuse Screening Test (H-S/EAST) followed a larger effort to identify indicators and…

  9. Assessment of the Diagnostic Potential of Clinotech TB Screen Test ...

    African Journals Online (AJOL)

    The Clinotech TB Screen test, a 3rd generation multi-antigen rapid chromatographic immunoassay for detection of IgG antibodies in serum against recombinant protein antigens 38kDa, 16kDa and 6kDa, was assessed for its diagnostic potential for diagnosis of active pulmonary TB in routine TB control programme in Abia ...

  10. Measurements for testing of fluoroscopic screens, including the photofluorographic units

    International Nuclear Information System (INIS)

    Balfanz, R.

    1986-01-01

    Image quality control measurements for fluoroscopic screens and photofluorographs have shown that both types of equipment have a long operating life, so that constancy and technical performance tests are absolutely necessary. It is recommended to conclude in-service maintenance contracts with the manufacturers. (DG) [de

  11. Tuberculosis Screening and Targeted Testing of College and University Students

    Science.gov (United States)

    Journal of American College Health, 2011

    2011-01-01

    Screening and targeted testing for tuberculosis (TB) is a key strategy for controlling and preventing infection on college and university campuses. Early detection provides an opportunity to promote the health of affected individuals through prompt diagnosis and treatment while preventing potential spread to others. Implementation of a screening…

  12. A population screening test for antibody to measles virus

    International Nuclear Information System (INIS)

    Friedman, M.G.

    1981-01-01

    In areas where sporadic cases of measles continue to occur in spite of vaccination programs, the availability of a simple screening test for determination of seropositivity to measles virus is desirable. A sensitive radioimmunoassay (RIA) screening test (ST) for the detection of IgG antibody to measles virus, based on a solid phase RIA, is described. The assays were performed on polyvinyl microtiter plates for which the RIAST requires only 5 μl of serum per subject. Antigen consisted of a sonicated extract of measles virus-infected Vero cells. Rabbit antihuman IgG specific for the Fc-segment of human IgG, labelled with 125 I, was used to detect human IgG bound to viral antigen. The basic RIA method was characterized by carrying out full titrations of sera of 53 healthy adults, 10 children, and 13 patients with measles-associated illness. These sera were also tested by the hemagglutination inhibition (HI) technique; most of the measles sera were also tested by complement fixation (CF). RIAST results (expressed as binding ratios) obtained for 52 healthy adults are compared with their RIA serum titers. Of the 200 sera of patients of various ages tested by the RIAST, 63 borderline sera were also tested by HI. The RIAST, which does not require serum treatment other than inactivation, proved to be more sensitive as an indicator of seropositivity than HI. Implications of the results and practical applications of the screening test are discussed. (author)

  13. Sero prevalence of hepatitis -C antibodies in blood donors

    International Nuclear Information System (INIS)

    Rahman, M.U.; Akhtar, G.N.; Lodhi, Y.

    2002-01-01

    Objective: To assess the prevalence of anti HCV antibodies in blood donors. Design: The retrospective sero-epidemiological data of the institute of Hematology and Blood Transfusion Service, Punjab over a period of one year after starting HCV screening, was analyzed to estimate the percentage prevalence. Setting; The data was obtained regularly from the blood units established by this institute at the pablic sector hospitals and retesting on initially reactive serum sample by EIA was done at the Institute. Subjects: A total of 166183 directed first time donors or replacement blood donors aged 18-60 years who donated blood at these blood banks or at mobile sessions have been included in the study. All initially reactive donors who tested non-reactive on EIA were excluded from the study. Main outcome Measures: Assessment of prevalence of HCV in blood donors. Results: 4.45% of the total donors intially tested reactive of these 0.36 % were atsety reactive on intial screening. Further testing by EIA, 4.1%. Conclusions: The blood transfusion service started screening for HCV in April 2000 and the prevalence of HCV, amongst the transfusion transmitted infections (TTIs) being screened for in the Punjab, is the highest. It is almost double the prevalence of HBV and several thousand time that of HIV. Meticulous and total screening coverage is needed to curtail impending catastrophe. With experience, the choice of testing methodology might have to be reviewed. (author)

  14. Validation of a telephone screening test for Alzheimer's disease.

    Science.gov (United States)

    Camozzato, Ana Luiza; Kochhann, Renata; Godinho, Claudia; Costa, Amanda; Chaves, Marcia L

    2011-03-01

    Financial constraints, mobility issues, medical conditions, crime in local areas can make cognitive assessment difficult for elders and telephone interviews can be a good alternative. This study was carried out to evaluate the reliability, validity and clinical utility of a Brazilian telephone version of the Mini Mental State Examination (Braztel-MMSE) in a community sample of healthy elderly participants and AD patients. The MMSE and the Braztel-MMSE were applied to 66 AD patients and 67 healthy elderly participants. The test-retest reliability was strong and significant (r = .92, p = .01), and the correlation between the Braztel-MMSE and the MMSE were significant (p = .01) and strong (r = .92). The general screening ability of the Braztel-MMSE was high (AUC = 0.982; CI95% = 0.964-1.001). This telephone version can therefore be used as a screening measure for dementia in older adults that need neuropsychological screening and cannot present for an evaluation.

  15. Tandem walking as a quick screening test for vestibular disorders.

    Science.gov (United States)

    Cohen, Helen S; Stitz, Jasmine; Sangi-Haghpeykar, Haleh; Williams, Susan P; Mulavara, Ajitkumar P; Peters, Brian T; Bloomberg, Jacob J

    2017-12-11

    Although many screening tests of balance are available, few of them have been well validated for clinical or research uses. The goal of this study was to test an updated version of an old test, Tandem Walking, to determine how useful it is for screening patients with vestibular disorders. Case-control study. Subjects were 90 adult patients with vestibular disorders and 292 healthy adult controls. They were tested on the number of correct tandem steps they could perform with arms crossed and eyes closed in a series of 10 steps. Correct steps could be nonconsecutive. Subjects were given one practice trial with eyes open and three experimental trials with eyes closed. Receiver operating characteristic (ROC), and sensitivity and specificity were calculated. ROC values, sensitivity, and specificity were, at best, only moderate, no matter how the age range was cut. Even for subjects in the age group with the highest ROC value (i.e., age less than 50 years), ROC = 0.8, sensitivity = 0.77, and specificity = 0.72. These results indicate that 23% of patients will not be identified. Therefore, we recommend that if this test is used for screening patients in the clinic or healthy volunteers, the result should be interpreted with care. 3b Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  16. Simple test guidelines for screening oilspill sorbents for toxicity

    International Nuclear Information System (INIS)

    Blenkinsopp, S.A.; Sergy, G.; Doe, K.; Jackman, P.; Huybers, A.

    1998-01-01

    Environment Canada's Emergencies Science Division has established a program to develop a standard test method suitable for evaluating the toxicity of common sorbent materials. Sorbents are used to absorb or adsorb spilled oil and other hazardous materials. They vary widely in composition and packaging. They are often treated with oleophilic and hydrophobic compounds to improve performance and have been used in large quantities during oil spills. Until now, their potential toxicity has never been considered. Three tests have been evaluated to determine how appropriate they are in screening the toxicity of sorbents. Seven toxicity test recommendations for sorbents were presented. 7 refs., 3 tabs., 2 figs

  17. Performance of ARCHITECT HCV core antigen test with specimens from US plasma donors and injecting drug users.

    Science.gov (United States)

    Mixson-Hayden, Tonya; Dawson, George J; Teshale, Eyasu; Le, Thao; Cheng, Kevin; Drobeniuc, Jan; Ward, John; Kamili, Saleem

    2015-05-01

    Hepatitis C virus (HCV) core antigen is a serological marker of current HCV infection. The aim of this study was mainly to evaluate the performance characteristics of the ARCHITECT HCV core antigen assay with specimens from US plasma donors and injecting drug users. A total of 551 serum and plasma samples with known anti-HCV and HCV RNA status were tested for HCV core antigen using the Abbott ARCHITECT HCV core antigen test. HCV core antigen was detectable in 100% of US plasma donor samples collected during the pre-seroconversion phase of infection (anti-HCV negative/HCV RNA positive). Overall sensitivity of the HCV core antigen assay was 88.9-94.3% in samples collected after seroconversion. The correlation between HCV core antigen and HCV RNA titers was 0.959. HCV core antigen testing may be reliably used to identify current HCV infection. Published by Elsevier B.V.

  18. A novel test tube method of screening for hemoglobin E.

    Science.gov (United States)

    Tatu, T; Kasinrerk, W

    2012-02-01

    Hemoglobin (Hb) E is a β-structural variant common worldwide. This Hb disorder can form a compound heterozygous state with the β-thalassemia gene, leading to life-threatening hereditary hemolytic anemia, HbE/β-thalassemia. Screening of HbE has proven to be a challenging practice in prevention and control of the HbE/β-thalassemia. A novel test tube method for HbE screening using diethyl aminoethyl (DEAE)-cellulose resin was described. With the developed system, HbE/A(2) did not bind to the resin and remained dissolved in the supernatant, whereas other Hbs completely bound to the resin. The red color of the supernatant observed in the test tube indicated the presence of HbE. Colorless or markedly pale color of the supernatant indicates the absence of HbE. Accuracy and efficiency of the established method in detecting HbE was comparable with the standard cellulose acetate electrophoresis method. The developed method is cheap and simple with no requirement of sophisticated equipment. The reagent could be stored at 4 °C for up to 5 months. Hemolysate samples aged up to 5 months were still suitable for this test. The described novel test tube method could be an alternative method of mass population screening for HbE, particularly in small health care facilities. © 2011 Blackwell Publishing Ltd.

  19. Older adults’ preferences for colorectal cancer-screening test attributes and test choice

    Directory of Open Access Journals (Sweden)

    Kistler CE

    2015-07-01

    Full Text Available Christine E Kistler,1–3 Thomas M Hess,4 Kirsten Howard,5,6 Michael P Pignone,2,3,7 Trisha M Crutchfield,2,3,8 Sarah T Hawley,9 Alison T Brenner,2 Kimberly T Ward,2 Carmen L Lewis10 1Department of Family Medicine, School of Medicine, 2Cecil G Sheps Center for Health Services Research, 3Lineberger Comprehensive Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, 4Department of Psychology, North Carolina State University, Raleigh, NC, USA; 5Institute for Choice, University of South Australia, Sydney, NSW, Australia; 6School of Public Health, University of Sydney, Sydney, NSW, Australia; 7Division of General Internal Medicine, School of Medicine, 8Center for Health Promotion and Disease Prevention, University of North Carolina at Chapel Hill, Chapel Hill, NC, 9Department of Medicine, University of Michigan, Ann Arbor, MI, 10Division of General Internal Medicine, Department of Medicine, University of Colorado School of Medicine, Aurora, CO, USA Background: Understanding which attributes of colorectal cancer (CRC screening tests drive older adults’ test preferences and choices may help improve decision making surrounding CRC screening in older adults.Materials and methods: To explore older adults’ preferences for CRC-screening test attributes and screening tests, we conducted a survey with a discrete choice experiment (DCE, a directly selected preferred attribute question, and an unlabeled screening test-choice question in 116 cognitively intact adults aged 70–90 years, without a history of CRC or inflammatory bowel disease. Each participant answered ten discrete choice questions presenting two hypothetical tests comprised of four attributes: testing procedure, mortality reduction, test frequency, and complications. DCE responses were used to estimate each participant’s most important attribute and to simulate their preferred test among three existing CRC-screening tests. For each individual, we compared the DCE

  20. Serological Testing in Screening for Adult Celiac Disease

    Directory of Open Access Journals (Sweden)

    Helen Rachel Gillett

    1999-01-01

    Full Text Available Assays for celiac-related antibodies are becoming widely available, and the present review aims to clarify the use of these investigations in the diagnosis of, management of and screening for adult celiac disease. The sensitivities and specificities of various antibody tests are discussed, along with their clinical use as an adjunct to small bowel biopsy, and as a first-line investigation for patients with atypical symptoms of celiac disease or patients at high risk of developing sprue.

  1. Reliability, Validity and Factor Structure of Drug Abuse Screening Test

    OpenAIRE

    Sayed Hadi Sayed Alitabar; Mojtaba Habibi; Maryam Falahatpisheh; Musa Arvin

    2016-01-01

    Background and Objective: According to the increasing of substance use in the country, more researches about this phenomenon are necessary. This Study Investigates the Validity, Reliability and Confirmatory Factor Structure of the Drug Abuse Screening test (DAST). Materials and Methods: The Sample Consisted of 381 Patients (143 Women and 238 Men) with a Multi-Stage Cluster Sampling of Areas 2, 6 and 12 of Tehran Were Selected from Each Region, 6 Randomly Selected Drug Rehabilitation Center. T...

  2. Discordant human T-lymphotropic virus screening with Western blot confirmation: evaluation of the dual-test algorithm for US blood donations.

    Science.gov (United States)

    Stramer, Susan L; Townsend, Rebecca L; Foster, Gregory A; Johnson, Ramona; Weixlmann, Barbara; Dodd, Roger Y

    2018-03-01

    Human T-lymphotropic virus (HTLV) blood donation screening has used a dual-testing algorithm beginning with either a chemiluminescent immunoassay or enzyme-linked immunosorbent screening assay (ELISA). Before the availability of a licensed HTLV supplemental assay, repeat-reactive (RR) samples on a first assay (Assay 1) were retested with a second screening assay (Assay 2). Donors with RR results by Assay 2 were deferred from blood donation and further tested using an unlicensed supplemental test to confirm reactivity while nonreactive (NR) donors remained eligible for donation until RR on a subsequent donation. This "dual-test" algorithm was replaced in May 2016 with the requirement that all RRs by Assay 1 be further tested by a licensed HTLV supplemental test (Western blot [WB]). In this study, we have requalified the dual-test algorithm using the available licensed HTLV WB. We tested 100 randomly selected HTLV RRs on screening Assay 1 (Abbott PRISM chemiluminescent immunoassay) but NR on screening Assay 2 (Avioq ELISA) by a Food and Drug Administration-licensed WB (MP Biomedicals) to ensure that no confirmed positives were among those that were RR by Assay 1 but NR by Assay 2. Of the 100 samples evaluated, 79 of 100 were WB seronegative, 21 of 100 indeterminate, and 0 of 100 seropositive. Of the 79 of 100 seronegative specimens, 73 of 79 did not express any bands on WB. We demonstrated that none of the 100 samples RR on Assay 1 but NR on Assay 2 were confirmed positive. This algorithm prevents such donors from requiring further testing and from being deferred. © 2018 AABB.

  3. Iterative Cellular Screening System for Nanoparticle Safety Testing

    Directory of Open Access Journals (Sweden)

    Franziska Sambale

    2015-01-01

    Full Text Available Nanoparticles have the potential to exhibit risks to human beings and to the environment; due to the wide applications of nanoproducts, extensive risk management must not be neglected. Therefore, we have constructed a cell-based, iterative screening system to examine a variety of nanoproducts concerning their toxicity during development. The sensitivity and application of various cell-based methods were discussed and proven by applying the screening to two different nanoparticles: zinc oxide and titanium dioxide nanoparticles. They were used as benchmarks to set up our methods and to examine their effects on mammalian cell lines. Different biological processes such as cell viability, gene expression of interleukin-8 and heat shock protein 70, as well as morphology changes were investigated. Within our screening system, both nanoparticle suspensions and coatings can be tested. Electric cell impedance measurements revealed to be a good method for online monitoring of cellular behavior. The implementation of three-dimensional cell culture is essential to better mimic in vivo conditions. In conclusion, our screening system is highly efficient, cost minimizing, and reduces the need for animal studies.

  4. Validation of the Cross-Cultural Alcoholism Screening Test (CCAST).

    Science.gov (United States)

    Gorenc, K D; Peredo, S; Pacurucu, S; Llanos, R; Vincente, B; López, R; Abreu, L F; Paez, E

    1999-01-01

    When screening instruments that are used in the assessment and diagnosis of alcoholism of individuals from different ethnicities, some cultural variables based on norms and societal acceptance of drinking behavior can play an important role in determining the outcome. The accepted diagnostic criteria of current market testing are based on Western standards. In this study, the Munich Alcoholism Test (31 items) was the base instrument applied to subjects from several Hispanic-American countries (Bolivia, Chile, Ecuador, Mexico, and Peru). After the sample was submitted to several statistical procedures, these 31 items were reduced to a culture-free, 31-item test named the Cross-Cultural Alcohol Screening Test (CCAST). The results of this Hispanic-American sample (n = 2,107) empirically demonstrated that CCAST measures alcoholism with an adequate degree of accuracy when compared to other available cross-cultural tests. CCAST is useful in the diagnosis of alcoholism in Spanish-speaking immigrants living in countries where English is spoken. CCAST can be used in general hospitals, psychiatric wards, emergency services and police stations. The test can be useful for other professionals, such as psychological consultants, researchers, and those conducting expertise appraisal.

  5. Screening for Specific Language Impairment in Preschool Children: Evaluating a Screening Procedure Including the Token Test.

    Science.gov (United States)

    Willinger, Ulrike; Schmoeger, Michaela; Deckert, Matthias; Eisenwort, Brigitte; Loader, Benjamin; Hofmair, Annemarie; Auff, Eduard

    2017-10-01

    Specific language impairment (SLI) comprises impairments in receptive and/or expressive language. Aim of this study was to evaluate a screening for SLI. 61 children with SLI (SLI-children, age-range 4-6 years) and 61 matched typically developing controls were tested for receptive language ability (Token Test-TT) and for intelligence (Wechsler Preschool-and-Primary-Scale-of-Intelligence-WPPSI). Group differences were analyzed using t tests, as well as direct and stepwise discriminant analyses. The predictive value of the WPPSI with respect to TT performance was analyzed using regression analyses. SLI-children performed significantly worse on both TT and WPPSI ([Formula: see text]). The TT alone yielded an overall classification rate of 79%, the TT and the WPPSI together yielded an overall classification rate of 80%. TT performance was significantly predicted by verbal intelligence in SLI-children and nonverbal intelligence in controls whilst WPPSI subtest arithmetic was predictive in both groups. Without further research, the Token Test cannot be seen as a valid and sufficient tool for the screening of SLI in preschool children but rather as a tool for the assessment of more general intellectual capacities. SLI-children at this age already show impairments typically associated with SLI which indicates the necessity of early developmental support or training. Token Test performance is possibly an indicator for a more general developmental factor rather than an exclusive indicator for language difficulties.

  6. Seroprevalence of toxoplasmosis in voluntary blood donors of Puducherry and surrounding districts of Tamil Nadu.

    Science.gov (United States)

    Stephen, Selvaraj; Pradeep, Jothimani; Anitharaj, Velmurugan; Janarthanam, Venkatraman

    2017-12-01

    Our objective is to study the seroprevalence of toxoplasmosis in the voluntary blood donors of Puducherry and surrounding districts of Tamil Nadu. A total of 275 healthy blood donors were screened for the presence of IgM and IgG antibodies to Toxoplasma gondii by ELISA test. Donor samples positive for IgM and/or IgG antibodies to T. gondii were subjected to IgG avidity ELISA. While, 54 out of 275 donors had IgG antibodies (19.66%), only one donor had IgM (0.36%) along with IgG. Among 54 IgG positive donors, only two had low avidity (3.7%), indicating recent exposure to the protozoa. Feasibility and cost effectiveness studies should be conducted throughout India to decide regarding screening of blood donors for toxoplasmosis.

  7. The validity of the Michigan Alcoholism Screening Test (MAST)

    DEFF Research Database (Denmark)

    Storgaard, H; Nielsen, S D; Gluud, C

    1994-01-01

    This review examines the validity of the Michigan Alcoholism Screening Test (MAST) as a screening instrument for alcohol problems. Studies that compare the MAST-questionnaire with other defined diagnostic criteria of alcohol problems were retrieved through MEDLINE and a cross-bibliographic check....... A total of 20 validity studies were included. The studies varied considerably regarding the prevalence of alcohol problems, the diagnostic criteria, and the examined patient categories. The MAST compared with other diagnostic criteria of alcohol problems gave validity measures with the following span...... and the specificities show substantial variations. The variables that seem to have the largest influence on the PVpos seem to be the prevalence of alcohol problems, the diagnostic method against which the MAST-questionnaire is validated, and the populations on which the MAST is applied. The MAST should in the future...

  8. ORIGINAL ARTICLE: Blood Donor’s Status of HIV, HBV, HCV and Syphilis in this Region of Marathwada, India

    Directory of Open Access Journals (Sweden)

    Rangrao H. Deshpande

    2012-07-01

    Full Text Available Aims & Objectives: Blood transfusion can cause the transmission of infections to recipients. This is an important mode of infection. The aim of study was to assess the prevalence of such type of infections among blood donors and to compare the seroprevalence of transfusion transmitted diseases in voluntary donors and replacement donors. Retrospective study of five years from Jan. 2007 to Dec. 2011 was done. This study was conducted at Blood bank, MIMSR Medical College Latur, Govt. Medical College, Latur and Bhalchandra Blood bank, Latur. Material & Methods: Total 10, 4925 donors were tested. Donors were screened for seroprevalence of HIV, HBC, HCV and Syphilis. Screening of HIV, HBV & HCV was done by ELISA method & Syphilis was screened by RPR type. Results: The comparison of seroprevalence of HIV, HBV, HCV & Syphilis in voluntary donors and replacement donors showed significant difference only for HIV in the years 2007, 2010, and 2011. Conclusion: The seroprevalence of transfusion transmitted diseases in the study is very low or negligible in voluntary donors as compared to replacement donors. There was a declining trend of seroprevalence for all the disease screened. But in our study the difference is not significant, which indicates that the selection of donors is of low quality. The selection of high quality voluntary donors should be achieved by creation of awareness by education of the prospective donor populations.

  9. Expanded newborn screening by mass spectrometry: New tests, future perspectives.

    Science.gov (United States)

    Ombrone, Daniela; Giocaliere, Elisa; Forni, Giulia; Malvagia, Sabrina; la Marca, Giancarlo

    2016-01-01

    Tandem mass spectrometry (MS/MS) has become a leading technology used in clinical chemistry and has shown to be particularly sensitive and specific when used in newborn screening (NBS) tests. The success of tandem mass spectrometry is due to important advances in hardware, software and clinical applications during the last 25 years. MS/MS permits a very rapid measurement of many metabolites in different biological specimens by using filter paper spots or directly on biological fluids. Its use in NBS give us the chance to identify possible treatable metabolic disorders even when asymptomatic and the benefits gained by this type of screening is now recognized worldwide. Today the use of MS/MS for second-tier tests and confirmatory testing is promising especially in the early detection of new disorders such as some lysosomal storage disorders, ADA and PNP SCIDs, X-adrenoleucodistrophy (X-ALD), Wilson disease, guanidinoacetate methyltransferase deficiency (GAMT), and Duchenne muscular dystrophy. The new challenge for the future will be reducing the false positive rate by using second-tier tests, avoiding false negative results by using new specific biomarkers and introducing new treatable disorders in NBS programs. © 2015 Wiley Periodicals, Inc.

  10. Co-Testing of Cervical Screening Tests in Detection of High Grade Cervical Intraepithelial Neoplasia

    Directory of Open Access Journals (Sweden)

    Smita Asthana

    2017-10-01

    Full Text Available Introduction: Co-testing performance for detection of high grade Cervical Intraepithelial Neoplasia (CIN has not been adequately addressed from Low Resource Countries (LRCs. Where isolated tests do not have adequate performance, further explorations are recommended. Aim: To evaluate the co-testing of conventional cervical screening tests such as Papanicolaou (Pap and Visual Inspection Cervix with Acetic Acid (VIA, with care HPV on Cervical Samples (CHPV or on Vaginal Samples (VHPV in the detection of high grade CIN. Materials and Methods: The cross-sectional study was conducted on ever married women of age 30 to 59 years in a rural community of Dadri. Women were screened by CHPV, VHPV, and Pap and VIA methods. Confirmation of screen positives was done by histology. Sensitivity, Specificity and likelihood ratios of different combinations of test determined to evaluate the performance. Results: Total eligible women, 66.2% (5032/7604 responded for screening. Analysis was performed on 4658, after excluding those who did not complete all screenings. Co-testing of CHPV (OR=246 or VHPV (OR=278 with Pap had highest association. Positive likelihood ratios of CHPV and VHPV with Pap in CIN II+ detection rates were 13.0 and 11.8 and in CIN III+ the detection rates were 18.0 and 16.0 respectively. Higher sensitivities and specificities were observed in co-testing for CIN III+ detection as against CIN II+ lesions. Conclusion: Choice of co-testing in a pair of tests for detection of high grade CIN is likely to depend on whether screening is targeted for developed or low resource country. VIA in isolation might not yield optimal results for LRCs.

  11. Reliability, Validity and Factor Structure of Drug Abuse Screening Test

    Directory of Open Access Journals (Sweden)

    Sayed Hadi Sayed Alitabar

    2016-05-01

    Full Text Available Background and Objective: According to the increasing of substance use in the country, more researches about this phenomenon are necessary. This Study Investigates the Validity, Reliability and Confirmatory Factor Structure of the Drug Abuse Screening test (DAST. Materials and Methods: The Sample Consisted of 381 Patients (143 Women and 238 Men with a Multi-Stage Cluster Sampling of Areas 2, 6 and 12 of Tehran Were Selected from Each Region, 6 Randomly Selected Drug Rehabilitation Center. The DAST Was Used as Instrument. Divergent & Convergent Validity of this Scale Was Assessed with Problems Assessment for Substance Using Psychiatric Patients (PASUPP and Relapse Prediction Scale (RPS.Results: The DAST after the First Time Factor Structure of Using Confirmatory Factor Analysis Was Confirmed. The DAST Had a Good Internal Consistency (Cranach’s Alpha, and the Reliability of the Test Within a Week, 0.9, 0.8. Also this Scale Had a Positive Correlation with Problems Assessment for Substance Using Psychiatric Patients and Relapse Prediction Scale (P<0.01.Conclusion: The Overall Results Showed that the Drug Abuse Screening Test in Iranian Society Is Valid. It Can Be Said that Self-Report Scale Tool Is Useful for Research Purposes and Addiction.

  12. Advances in prenatal screening for Down syndrome: II first trimester testing, integrated testing, and future directions.

    Science.gov (United States)

    Benn, Peter A

    2002-10-01

    The acceptability of prenatal screening and diagnosis of Down syndrome is dependent, in part, on the gestational age at which the testing is offered. First trimester screening could be advantageous if it has sufficient efficacy and can be effectively delivered. Two first trimester maternal serum screening markers, pregnancy-associated plasma protein-A (PAPP-A) and free beta-human chorionic gonadotropin (beta-hCG), are useful for identifying women at increased risk for fetal Down syndrome. In addition, measurement of an enlarged thickness of the subcutaneous fluid-filled space at the back of the neck of the developing fetus (referred to as nuchal translucency or NT) has been demonstrated to be an indicator for these high-risk pregnancies. When these three parameters are combined, estimates for Down syndrome efficacy exceed those currently attainable in the second trimester. Women who are screen-positive in the first trimester can elect to receive cytogenetic testing of a chorionic villus biopsy. The first trimester tests could also, theoretically, be combined with the second trimester maternal serum screening tests (integrated screening) to obtain even higher levels of efficacy. There are, however, several practical limitations to first trimester and integrated screening. These include scheduling of testing within relatively narrow gestational age intervals, availability of appropriately trained ultrasonographers for NT measurement, risks associated with chorionic villus biopsy, and costs. There is also increasing evidence that an enlarged NT measurement is indicative of a high risk for spontaneous abortion and for fetal abnormalities that are not detectable by cytogenetic analysis. Women whose fetuses show enlarged NT, therefore, need first trimester counseling regarding their Down syndrome risks and the possibility of other adverse pregnancy outcomes. Follow-up ultrasound and fetal echocardiography in the second trimester are also indicated. First trimester

  13. DAT positivity in blood donors: a perplexing scenario.

    Science.gov (United States)

    Bedi, Ravneet Kaur; Mittal, Kshitija; Sood, Tanvi; Kumar, Rakesh; Praveen, Ajay S

    2014-04-01

    A blood request was received for 70 year male patient suffering from Chronic Obstructive Pulmonary Disease with anemia. One unit was found incompatible in AHG phase. Patient's antibody screen, indirect antiglobulin test (IAT), direct antiglobulin test (DAT) and auto control was negative. DAT of donor unit was positive with anti IgG gel card and negative with C3d reagent along with positive auto control. Donor was 30 year male with no history of blood transfusion and medication and had no evidence of hemolysis. Donors with positive DAT should be deferred, notified and referred to physician but further studies are required. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. How to encourage non-donors to be more willing to donate blood? Testing of binding communication based interventions.

    Science.gov (United States)

    Fonte, D; Blondé, J; Girandola, F

    2017-06-01

    Our study aims to test the effectiveness of binding communication based interventions (vs classical persuasive communication based ones) inciting non-donors to act in favour of blood donation. The implementation of effective communication interventions represents a major public health issue. Nevertheless, persuasive media campaigns appear to have little effect on behaviours. Even though non-donors hold a positive attitude towards blood donation, they are not inclined to donate. As an alternative to producing behavioural changes, many recent studies have shown the superiority of binding communication over persuasive communication. All participants, non-donors, were randomly assigned to one of four experimental conditions of a 2 (type of communication: persuasive vs binding) × 2 (source credibility: low vs high) factorial design. Then, they were asked to report their intention to donate blood, and their intention to distribute leaflets regarding blood donation. Binding communication is a more effective strategy for increasing intention towards blood donation compared with persuasive communication, especially when combined with high credibility source. Accordingly this study calls for more consideration of knowledge of social psychology to design effective communication interventions and increase the number of donations. © 2016 British Blood Transfusion Society.

  15. Rapid screening test for porphyria diagnosis using fluorescence spectroscopy

    Science.gov (United States)

    Lang, A.; Stepp, H.; Homann, C.; Hennig, G.; Brittenham, G. M.; Vogeser, M.

    2015-07-01

    Porphyrias are rare genetic metabolic disorders, which result from deficiencies of enzymes in the heme biosynthesis pathway. Depending on the enzyme defect, different types of porphyrins and heme precursors accumulate for the different porphyria diseases in erythrocytes, liver, blood plasma, urine and stool. Patients with acute hepatic porphyrias can suffer from acute neuropathic attacks, which can lead to death when undiagnosed, but show only unspecific clinical symptoms such as abdominal pain. Therefore, in addition to chromatographic methods, a rapid screening test is required to allow for immediate identification and treatment of these patients. In this study, fluorescence spectroscopic measurements were conducted on blood plasma and phantom material, mimicking the composition of blood plasma of porphyria patients. Hydrochloric acid was used to differentiate the occurring porphyrins (uroporphyrin-III and coproporphyrin-III) spectroscopically despite their initially overlapping excitation spectra. Plasma phantom mixtures were measured using dual wavelength excitation and the corresponding concentrations of uroporphyrin-III and coproporphyrin-III were determined. Additionally, three plasma samples of porphyria patients were examined and traces of coproporphyrin-III and uroporphyrin-III were identified. This study may therefore help to establish a rapid screening test method with spectroscopic differentiation of the occurring porphyrins, which consequently allows for the distinction of different porphyrias. This may be a valuable tool for clinical porphyria diagnosis and rapid or immediate treatment.

  16. Development of a Pitch Discrimination Screening Test for Preschool Children.

    Science.gov (United States)

    Abramson, Maria Kulick; Lloyd, Peter J

    2016-04-01

    There is a critical need for tests of auditory discrimination for young children as this skill plays a fundamental role in the development of speaking, prereading, reading, language, and more complex auditory processes. Frequency discrimination is important with regard to basic sensory processing affecting phonological processing, dyslexia, measurements of intelligence, auditory memory, Asperger syndrome, and specific language impairment. This study was performed to determine the clinical feasibility of the Pitch Discrimination Test (PDT) to screen the preschool child's ability to discriminate some of the acoustic demands of speech perception, primarily pitch discrimination, without linguistic content. The PDT used brief speech frequency tones to gather normative data from preschool children aged 3 to 5 yrs. A cross-sectional study was used to gather data regarding the pitch discrimination abilities of a sample of typically developing preschool children, between 3 and 5 yrs of age. The PDT consists of ten trials using two pure tones of 100-msec duration each, and was administered in an AA or AB forced-choice response format. Data from 90 typically developing preschool children between the ages of 3 and 5 yrs were used to provide normative data. Nonparametric Mann-Whitney U-testing was used to examine the effects of age as a continuous variable on pitch discrimination. The Kruskal-Wallis test was used to determine the significance of age on performance on the PDT. Spearman rank was used to determine the correlation of age and performance on the PDT. Pitch discrimination of brief tones improved significantly from age 3 yrs to age 4 yrs, as well as from age 3 yrs to the age 4- and 5-yrs group. Results indicated that between ages 3 and 4 yrs, children's auditory discrimination of pitch improved on the PDT. The data showed that children can be screened for auditory discrimination of pitch beginning with age 4 yrs. The PDT proved to be a time efficient, feasible tool for

  17. Risk of breast cancer after false-positive test results in screening mammography

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My Catarina; Risør, Louise Madeleine; Thorsted, Brian Larsen

    2012-01-01

    Screening for disease in healthy people inevitably leads to some false-positive tests in disease-free individuals. Normally, women with false-positive screening tests for breast cancer are referred back to routine screening. However, the long-term outcome for women with false-positive tests...

  18. Radionuclide transit: a sensitive screening test for esophageal dysfunction

    International Nuclear Information System (INIS)

    Russell, C.O.; Hill, L.D.; Holmes, E.R. III; Hull, D.A.; Gannon, R.; Pope, C.E. II.

    1981-01-01

    The purpose of this study was to extend existing nuclear medicine techniques for the diagnosis of esophageal motor disorders. A standard homogeneous bolus of 99mtechnetium sulfur colloid in water was swallowed in the supine position under the collimator of a gamma camera linked to a microprocessor. Bolus transit was recorded at 0.4-s intervals, and the movie obtained was used to analyze transit in an objective manner. Ten normal volunteers and 30 subjects with dysphagia not related to mechanical obstruction were studied with this technique. Radionuclide transit studies detected a higher incidence of esophageal motor abnormality than manometry or radiology in the dysphagia group. In addition a definitive description of the functional problem was possible in most cases. Radionuclide transit is a safe noninvasive test and suitable as a screening test for esophageal motor disorders

  19. Radionuclide transit: a sensitive screening test for esophageal dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Russell, C.O.; Hill, L.D.; Holmes, E.R. III; Hull, D.A.; Gannon, R.; Pope, C.E. II

    1981-05-01

    The purpose of this study was to extend existing nuclear medicine techniques for the diagnosis of esophageal motor disorders. A standard homogeneous bolus of 99mtechnetium sulfur colloid in water was swallowed in the supine position under the collimator of a gamma camera linked to a microprocessor. Bolus transit was recorded at 0.4-s intervals, and the movie obtained was used to analyze transit in an objective manner. Ten normal volunteers and 30 subjects with dysphagia not related to mechanical obstruction were studied with this technique. Radionuclide transit studies detected a higher incidence of esophageal motor abnormality than manometry or radiology in the dysphagia group. In addition a definitive description of the functional problem was possible in most cases. Radionuclide transit is a safe noninvasive test and suitable as a screening test for esophageal motor disorders.

  20. PROSTATE CANCER SCREENING: PSA TEST AWARENESS AMONG ADULT MALES.

    Science.gov (United States)

    Obana, Michael; O'Lawrence, Henry

    2015-01-01

    The overall purpose of this study was to determine whether visits to the doctor in the last 12 months, education level, and annual household income for adult males increased the awareness of prostate-specific antigen (PSA) tests. The effect of these factors for the knowledge of PSA exams was performed using statistical analysis. A retrospective secondary database was utilized for this study using the questionnaire in the California Health Interview Survey from 2009. Based on this survey, annual visits to the doctor, higher educational levels attained, and greater take-home pay were statistically significant and the results of the study were equivalent to those hypothesized. This also reflects the consideration of marketing PSA blood test screenings to those adult males who are poor, uneducated, and do not see the doctor on a consistent basis.

  1. Pain on Functional Movement Screen Tests and Injury Risk.

    Science.gov (United States)

    Bushman, Timothy T; Grier, Tyson L; Canham-Chervak, Michelle C; Anderson, Morgan K; North, William J; Jones, Bruce H

    2015-11-01

    The Functional Movement Screen (FMS) is a tool intended to evaluate limitations or asymmetries of movement to detect individuals at risk for exercise- and sports-related injury. The purpose was to determine the association and predictive value of specific FMS tests with injury risk in physically active men. Soldiers aged 18-57 years completed the FMS (n = 2,476). Demographic and fitness data were collected by survey. Medical record data for any, overuse, and traumatic injury 6 months after the assessment were obtained. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated along with receiver operator characteristics to determine area under the curve (AUC). Risks, risk ratios, odds ratios (ORs), and 95% confidence intervals were calculated to assess injury risks. Multivariate logistic regression identified that pain on 5 of the 7 tests was associated with greater risk for any injury (OR = 1.50-3.51): deep squat, hurdle step, in-line lunge, trunk stability push-up, and rotary stability. However, FMS registered low sensitivity, PPV, and AUC for all 7 tests for the 3 injury types (2-24% sensitivity, 16-74% PPV, and 50-58% AUC). Although the presence of pain was associated with a higher risk of injury on 5 tests, a low sensitivity, PPV, and AUC were displayed. Therefore, caution is advised when implementing the FMS as a screening tool in an Army or similarly active population as it could lead to prevention and treatment resources being directed toward individuals who are not at greater risk for injury.

  2. Donor deferral due to anemia: A tertiary care center-based study

    Directory of Open Access Journals (Sweden)

    Bahadur Shalini

    2011-01-01

    Full Text Available Background: The minimum hemoglobin cutoff for blood donation in India is 12.5 gm% for both male and female donors and the minimum donation interval is 3 months. Donation of one unit of blood results in decrease in hemoglobin by 1 gm% and loss of 200-250 mg of iron. Donor deferral due to anemia is one of the major reasons of temporary rejection of blood donors. In the absence of further workup or advise, it results in loss of valuable donor base. Aim and Objective: To provide baseline information regarding the prevalence and spectrum of anemia in prospective blood donors to help plan a future strategy for donor management. Materials and Methods: Hemoglobin testing of donors was performed using Hemocue and Copper sulfate specific gravity method. Ethylene diamine tetraacetic acid sample of all the donors who failed either or both the screening tests was tested on automated analyzer for evaluation of hemoglobin and red blood cell indices. Results: Of all the donors, 15.5% were deferred due to anemia. Prevalence of anemia in prospective blood donors was 1.8%. It was significantly higher in female donors compared with male donors (34.2% vs 1.2%. The most common type of anemia was normocytic normochromic.

  3. Zagreb Amblyopia Preschool Screening Study: near and distance visual acuity testing increase the diagnostic accuracy of screening for amblyopia.

    Science.gov (United States)

    Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka

    2016-02-01

    To present and evaluate a new screening protocol for amblyopia in preschool children. Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. The ZAPS study used the most discriminative VA test with optotypes in line as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia.

  4. Testing the tests--an empirical evaluation of screening tests for the detection of cognitive impairment in aviators.

    Science.gov (United States)

    Stokes, A F; Banich, M T; Elledge, V C

    1991-08-01

    The FAA has expressed concern that flight safety could be compromised by undetected cognitive impairment in pilots due to conditions such as substance abuse, mental illness, and neuropsychological problems. Interest has been shown in the possibility of adding a brief "mini-mental exam," or a simple automated test-battery to the standard flight medical to screen for such conditions. The research reported here involved the empirical evaluation of two "mini-mental exams," two paper-and-pencil test batteries, and a prototype version of an automated screening battery. Sensitivity, specificity, and positive predictive value were calculated for each sub-task in a discriminant study of 54 pilots and 62 individuals from a heterogeneous clinical population. Results suggest that the "mini-mental exams" are poor candidates for a screening test. The automated battery showed the best discrimination performance, in part because of the incorporation of dual-task tests of divided attention performance. These tests appear to be particularly sensitive to otherwise difficult-to-detect cognitive impairments of a mild or subtle nature. The use of an automated battery of tests as a screening instrument does appear to be feasible in principle, but the practical success of a screening program is heavily dependent upon the actual prevalence of cognitive impairment in the medical applicant population.

  5. [Lack of knowledge among blood donors in Burkina Faso (West Africa); potential obstacle to transfusion security].

    Science.gov (United States)

    Nébié, K Y; Olinger, C M; Kafando, E; Dahourou, H; Diallo, S; Kientega, Y; Domo, Y; Kienou, K; Ouattara, S; Sawadogo, I; Ky, L; Muller, C P

    2007-11-01

    The measures recommended to reduce TTD include clinical selection of donors, based on a standardized questionnaire which aims to find out antecedents and behaviours predicting transmitted diseases within donors. The effectiveness of this measure is well established in the industrialized countries where the level of education of the population may support a greater receptivity of donors about this procedure. What is happening in developing one? This study was carried out to assess knowledge attitude and behaviours among blood donors regarding blood and transfusion safety in Burkina Faso. A cross sectional study was carried out in the blood bank of the teaching hospital of Ouagadougou. In addition to the routine questionnaire, 544 included blood donors were subjected to additional questions seeking to specify their behaviours, knowledge and attitude towards TTD diseases and screening. Donors were from 16 to 57 years of age (mean age : 28+/-7.9 years). The majority of donors were male (71.2%). Family donors represent 52% and first time donors 55%. About 30.8% were illiterate or of primary school level. A percentage of 14.4 donate to access HIV testing and 30.7% will donate blood immediately to check any contamination in case of exposure. There was no difference between donors having been informed about their HIV status in the past and the other donors regarding HIV, HBs Ag and VHC results. This study suggests that there is some great need for donors' education on transfusion safety. There is also need for staff training in donors' management.

  6. Screens

    OpenAIRE

    2016-01-01

    This Sixth volume in the series The Key Debates. Mutations and Appropriations in European Film Studies investigates the question of screens in the context both of the dematerialization due to digitalization and the multiplication of media screens. Scholars offer various infomations and theories of topics such as the archeology of screen, film and media theories, contemporary art, pragmatics of new ways of screening (from home video to street screening).

  7. Subjective and objective screening tests for hydroxychloroquine toxicity.

    Science.gov (United States)

    Cukras, Catherine; Huynh, Nancy; Vitale, Susan; Wong, Wai T; Ferris, Fredrick L; Sieving, Paul A

    2015-02-01

    To compare subjective and objective clinical tests used in the screening for hydroxychloroquine retinal toxicity to multifocal electroretinography (mfERG) reference testing. Prospective, single-center, case control study. Fifty-seven patients with a previous or current history of hydroxychloroquine treatment of more than 5 years' duration. Participants were evaluated with a detailed medical history, dilated ophthalmologic examination, color fundus photography, fundus autofluorescence (FAF) imaging, spectral-domain (SD) optical coherence tomography (OCT), automated visual field testing (10-2 visual field mean deviation [VFMD]), and mfERG testing. We used mfERG test parameters as a gold standard to divide participants into 2 groups: those affected by hydroxychloroquine-induced retinal toxicity and those unaffected. We assessed the association of various imaging and psychophysical variables in the affected versus the unaffected group. Fifty-seven study participants (91.2% female; mean age, 55.7±10.4 years; mean duration of hydroxychloroquine treatment, 15.0±7.5 years) were divided into affected (n = 19) and unaffected (n = 38) groups based on mfERG criteria. Mean age and duration of hydroxychloroquine treatment did not differ statistically between groups. Mean OCT retinal thickness measurements in all 9 macular subfields were significantly lower (<40 μm) in the affected group (P < 0.01 for all comparisons) compared with those in the unaffected group. Mean VFMD was 11 dB lower in the affected group (P < 0.0001). Clinical features indicative of retinal toxicity were scored for the 2 groups and were detected in 68.4% versus 0.0% using color fundus photographs, 73.3% versus 9.1% using FAF images, and 84.2% versus 0.0% on the scoring for the perifoveal loss of the photoreceptor ellipsoid zone on SD-OCT for affected and unaffected participants, respectively. Using a polynomial modeling approach, OCT inner ring retinal thickness measurements and Humphrey 10-2 VFMD were

  8. Mechanized toxicological serum tests in screening hospitalized patients.

    Science.gov (United States)

    Hallbach, J; Guder, W G

    1991-09-01

    provided by the EMIT tox test kits. As a consequence, decision limits for all three group tests in serum were lowered to near the detection limit: (table: see text) For quantitative tests the lower limits of quantification were: (table: see text) The working reagents were stable for at least 14 days at 4-8 degrees C. Calibration curves were stable over the expiration period of reconstituted original reagents (6-12 weeks), also when working reagents were prepared in aliquots from stored reconstituted reagents. Application of the newly adapted programme to serum samples of nearly two hundred patients showed it to be suitable for screening patients in which intoxication is suspected or needs to be excluded.

  9. Seroprevalence & changing trends of transfusion-transmitted infections amongst blood donors in a Regional Blood Transfusion Centre in north India

    Directory of Open Access Journals (Sweden)

    Akanksha Rawat

    2017-01-01

    Interpretation & conclusions: The increase in public awareness regarding voluntary blood donation, meticulous donor screening, counselling and use of highly sensitive tests can help in reducing the risk of TTIs.

  10. The Relationship between Preeclampsia and Quadruple Screening Test in Nuliparous

    Directory of Open Access Journals (Sweden)

    Farnaz Zand Vakili

    2017-01-01

    Full Text Available Introduction: Early diagnosis and prediction of preeclampsia needs appropriate obstetric care. Preeclampsia predicting methods are important. This study was designed to determine the correlation between preeclampsia and quadruple screening test in the nulliparous. Materials and Methods:  This case - control study was conducted on 54 pregnant women with preeclampsia (case group and 108 healthy pregnant women (control group who referred to health centers in Sanandaj, Iran. Ultrasonography was performed to determine the gestational age by a radiologist. Maternal serum levels of alpha fetoprotein (AFP, human chorionic gonadotropin (hCG, unconjugated estriol (uE3, and inhibin-A were measured in the second trimester of pregnancy. Data were analyzed using SPSS statistical software and Chi-square test, T-test, sensitivity, specificity, positive and negative predictive values. Results: The results showed that the sensitivity and specificity for the diagnosis of preeclampsia in pregnant women for hCG were 35.2% and 79.6 respectively. These findings for estriol were 20.4% and 88.9%, for inhibin-A were 38.8% and 88% and for alpha fetoprotein were 38.8% and 74.1%. The positive predictive value for hCG, estriol, inhibin-A and alpha fetoprotein were 46.3%, 47.8%, 61.8% and 42.9% respectively. The negative predictive value for hCG, estriol, inhibin-A and alpha fetoprotein were also 71%, 69.1%, 74.2% and 70.8% respectively. Conclusion: There was a relationship between preeclampsia and high levels of inhibin-A and hCG. Further studies on these markers and evaluating their usefulness in the diagnosis and management of preeclampsia are recommended.

  11. Computerized visuo-spatial memory test as a supplementary screening test for dementia.

    Science.gov (United States)

    Maki, Yohko; Yoshida, Hiroshi; Yamaguchi, Haruyasu

    2010-06-01

    To prepare for a super-aging society, effective dementia screening tests are required. The most salient deficit appearing from the early stages of dementia/Alzheimer's disease (AD) is a deterioration in memory. The Hasegawa Dementia Scale-revised (HDS-R) and the Mini-Mental State Examination (MMSE) are widely used in Japan to screen for dementia. Both place an emphasis on memory function, but neither examines visuo-spatial memory (VSM) function, even though VSM deficits are a sensitive marker for the detection of conversion to dementia. Furthermore, brief tests of VSM that are appropriate for screening have not been standardized. Thus, in the present study, we devised a brief, computer-aided short-term VSM test. Sixty-six aged people were evaluated. Using the Clinical Dementia Rating (CDR), it was found that 29 could be considered normal controls (NC; CDR 0), 10 had mild cognitive impairment (MCI; CDR 0.5), 15 had mild dementia (CDR 1), and 12 had moderate to severe dementia (CDR 2-3). The VSM test estimated how many locations each subject could memorize. Several numbered circles were shown on a monitor and subjects were required to memorize the location of these circles sequentially. After the numbers on the circles on the screen had disappeared, the subjects were required to indicate the circles in ascending order. A touch panel screen was used for this test to make it easier. The HDS-R was applied to subjects with MCI and dementia. The mean (+/-SD) VSM score in subjects with MCI (5.70 +/- 0.96) was significantly lower than that in NC subjects (6.69 +/- 0.82), but significantly higher than that in subjects classified as CDR 1 (4.67 +/- 0.87). There was no significant difference in VSM scores between subjects classified as CDR 1 and CDR 2-3 (3.80 +/- 0.80). There was a moderate significant correlation between VSM and HDS-R scores. In the present study, the VSM test detected differences in VSM function among NC subjects and subjects with MCI and mild dementia. The

  12. Cost-effectiveness of one versus two sample faecal immunochemical testing for colorectal cancer screening

    NARCIS (Netherlands)

    S.L. Goede (Luuk); A.H.C. Roon (Aafke); J.C.I.Y. Reijerink (Jacqueline); A.J. van Vuuren (Hanneke); I. Lansdorp-Vogelaar (Iris); J.D.F. Habbema (Dik); E.J. Kuipers (Ernst); M.E. van Leerdam (Monique); M. van Ballegooijen (Marjolein)

    2013-01-01

    textabstractObjective The sensitivity and specificity of a single faecal immunochemical test (FIT) are limited. The performance of FIT screening can be improved by increasing the screening frequency or by providing more than one sample in each screening round. This study aimed to evaluate if

  13. Does offering prenatal screening influence pregnant women's attitudes regarding prenatal testing?

    NARCIS (Netherlands)

    Kleinveld, J.H.; van den Berg, M.; van Eijk, J.T.; van Vugt, J.M.G.; van der Wal, G.; Timmermans, D.R.M.

    2008-01-01

    Objectives: This study aims to find out whether offering prenatal screening for Down syndrome and neural tube defects influences pregnant women's attitudes toward having a screening test. Methods: Women were randomised into a group that was offered prenatal screening and a group that was not offered

  14. Colon cancer screening

    Science.gov (United States)

    Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...

  15. Participation in prenatal screening tests and intentions concerning selective termination in Finnish maternity care

    DEFF Research Database (Denmark)

    Santalahti, P; Hemminki, E; Aro, A R

    1999-01-01

    AIMS: The study examined how prenatal screening tests are presented to women, factors associated with women's participation in screening, their experience of decision-making and intentions concerning pregnancy termination, and hospital data on rates of selective terminations. METHODS: Questionnai......AIMS: The study examined how prenatal screening tests are presented to women, factors associated with women's participation in screening, their experience of decision-making and intentions concerning pregnancy termination, and hospital data on rates of selective terminations. METHODS...... as a routine procedure. Most women (92%) underwent serum screening and most (86%) found the decision to participate or not easy. In almost every aspect of presentation and participation studied, serum and ultrasound screening differed from each other. 85% of respondents to ultrasound screening answered...... in screening and with intentions about selective termination, women's perceptions of lives of the disabled should receive more attention in future studies....

  16. Does population screening for Chlamydia trachomatis raise anxiety among those tested? Findings from a population based chlamydia screening study

    Directory of Open Access Journals (Sweden)

    Low Nicola

    2006-04-01

    Full Text Available Abstract Background The advent of urine testing for Chlamydia trachomatis has raised the possibility of large-scale screening for this sexually transmitted infection, which is now the most common in the United Kingdom. The purpose of this study was to investigate the effect of an invitation to be screened for chlamydia and of receiving a negative result on levels of anxiety, depression and self-esteem. Methods 19,773 men and women aged 16 to 39 years, selected at random from 27 general practices in two large city areas (Bristol and Birmingham were invited by post to send home-collected urine samples or vulvo-vaginal swabs for chlamydia testing. Questionnaires enquiring about anxiety, depression and self-esteem were sent to random samples of those offered screening: one month before the dispatch of invitations; when participants returned samples; and after receiving a negative result. Results Home screening was associated with an overall reduction in anxiety scores. An invitation to participate did not increase anxiety levels. Anxiety scores in men were lower after receiving the invitation than at baseline. Amongst women anxiety was reduced after receipt of negative test results. Neither depression nor self-esteem scores were affected by screening. Conclusion Postal screening for chlamydia does not appear to have a negative impact on overall psychological well-being and can lead to a decrease in anxiety levels among respondents. There is, however, a clear difference between men and women in when this reduction occurs.

  17. Does population screening for Chlamydia trachomatis raise anxiety among those tested? Findings from a population based chlamydia screening study.

    Science.gov (United States)

    Campbell, Rona; Mills, Nicola; Sanford, Emma; Graham, Anna; Low, Nicola; Peters, Tim J

    2006-04-25

    The advent of urine testing for Chlamydia trachomatis has raised the possibility of large-scale screening for this sexually transmitted infection, which is now the most common in the United Kingdom. The purpose of this study was to investigate the effect of an invitation to be screened for chlamydia and of receiving a negative result on levels of anxiety, depression and self-esteem. 19,773 men and women aged 16 to 39 years, selected at random from 27 general practices in two large city areas (Bristol and Birmingham) were invited by post to send home-collected urine samples or vulvo-vaginal swabs for chlamydia testing. Questionnaires enquiring about anxiety, depression and self-esteem were sent to random samples of those offered screening: one month before the dispatch of invitations; when participants returned samples; and after receiving a negative result. Home screening was associated with an overall reduction in anxiety scores. An invitation to participate did not increase anxiety levels. Anxiety scores in men were lower after receiving the invitation than at baseline. Amongst women anxiety was reduced after receipt of negative test results. Neither depression nor self-esteem scores were affected by screening. Postal screening for chlamydia does not appear to have a negative impact on overall psychological well-being and can lead to a decrease in anxiety levels among respondents. There is, however, a clear difference between men and women in when this reduction occurs.

  18. Impact of a confirmatory RhD test on the correct serologic typing of blood donors

    Directory of Open Access Journals (Sweden)

    Luciana Cayres Schmidt

    2015-10-01

    Full Text Available BACKGROUND: The RHD gene is highly polymorphic, which results in a large number of RhD variant phenotypes. Discrepancies in RhD typing are still a problem in blood banks and increase the risk of alloimmunization. In this study, the RhD typing strategy at a blood bank in Brazil was evaluated.METHODS: One-hundred and fifty-two samples typed as RhD negative and C or E positive by routine tests (automated system and indirect antiglobulin test using the tube technique were reevaluated for RhD status by three methods. The method with the best performance was implemented and evaluated for a period of one year (n = 4897 samples. Samples that were D positive exclusively in the confirmatory test were submitted to molecular analysis.RESULTS: The gel test for indirect antiglobulin testing with anti-D immunoglobulin G (clone ESD1 presented the best results. Seventy samples (1.43% previously typed as RhD negative showed reactivity in the gel test for indirect antiglobulin testing and were reclassified as D positive. D variants that may cause alloimmunization, such as weak D type 2 and partial DVI, were detected.CONCLUSION: The confirmatory RhD test using the gel test for indirect antiglobulin testing represents a breakthrough in transfusion safety in this blood center. Our results emphasize the importance of assessing the blood group typing strategy in blood banks.

  19. 40 CFR 799.9355 - TSCA reproduction/developmental toxicity screening test.

    Science.gov (United States)

    2010-07-01

    ... developmental defects should not be used. Healthy virgin animals, not subjected to previous experimental..., except legal holidays. (1) OECD (1995). Reproduction/Developmental Toxicity Screening Test, OECD 421...

  20. Asymptomatic malaria and associated factors among blood donors ...

    African Journals Online (AJOL)

    Dr.Mirambo

    use of malaria rapid diagnostic test (MRDT). Results: A total of 150 blood donors participated in this study. The median age of ... transfusion, the World Health Organization (WHO) recommends the blood collected for transfusion to be screened for presence of Hepatitis B Virus (HBV), Hepatitis C Virus (HBV), Syphilis.

  1. Self-Sampling for Human Papillomavirus Testing: Increased Cervical Cancer Screening Participation and Incorporation in International Screening Programs

    Science.gov (United States)

    Gupta, Sarah; Palmer, Christina; Bik, Elisabeth M.; Cardenas, Juan P.; Nuñez, Harold; Kraal, Laurens; Bird, Sara W.; Bowers, Jennie; Smith, Alison; Walton, Nathaniel A.; Goddard, Audrey D.; Almonacid, Daniel E.; Zneimer, Susan; Richman, Jessica; Apte, Zachary S.

    2018-01-01

    In most industrialized countries, screening programs for cervical cancer have shifted from cytology (Pap smear or ThinPrep) alone on clinician-obtained samples to the addition of screening for human papillomavirus (HPV), its main causative agent. For HPV testing, self-sampling instead of clinician-sampling has proven to be equally accurate, in particular for assays that use nucleic acid amplification techniques. In addition, HPV testing of self-collected samples in combination with a follow-up Pap smear in case of a positive result is more effective in detecting precancerous lesions than a Pap smear alone. Self-sampling for HPV testing has already been adopted by some countries, while others have started trials to evaluate its incorporation into national cervical cancer screening programs. Self-sampling may result in more individuals willing to participate in cervical cancer screening, because it removes many of the barriers that prevent women, especially those in low socioeconomic and minority populations, from participating in regular screening programs. Several studies have shown that the majority of women who have been underscreened but who tested HPV-positive in a self-obtained sample will visit a clinic for follow-up diagnosis and management. In addition, a self-collected sample can also be used for vaginal microbiome analysis, which can provide additional information about HPV infection persistence as well as vaginal health in general. PMID:29686981

  2. Comparison of the automated vision screening test to the Snellen test.

    Science.gov (United States)

    Gofin, R; Falk, M

    1991-03-01

    The comparison of an automatic vision screening machine using the Landolt rings and the usual Snellen Chart was carried out among 123 second grade and 149 fifth grade students in an elementary school in Jerusalem. The sensitivity of the test for a cut-off point of greater than or equal to 6/12 according to the Snellen test was 41.7% (CI = 16.5-71.4) and the specificity was 86.5% (CI 78.1-92.2) for second graders. For fifth graders the values were 50.0% (CI = 20.1-79.9) and 90.6% (CI 83.7-94.8) respectively. Diagnosis by a specialist decreased the number of 'false negatives' and confirmed the pathological cases. The automatic test was well accepted by the children. Though more time is needed for assessment using the automatic test, its advantage is that no professional staff are required.

  3. The problem of false-positive human papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Frederiksen, Maria Eiholm

    2013-01-01

    Human Papillomavirus (HPV) testing has been extensively studied in randomized controlled trials of primary cervical screening. Based on encouraging results concerning its high detection rates and a high negative predictive value for high-grade cervical intraepithelial neoplasia (CIN), HPV testing...... will probably replace cytology in future primary cervical screening. However, HPV testing is associated with more frequent false-positive tests compared to cytology. False-positive tests are defined as positive screening tests which are not subsequently confirmed with high-grade CIN. Several authors have...

  4. Validity of Forced Eyelid Closure Test: A Novel Clinical Screening Test for Ocular Myasthenia Gravis.

    Science.gov (United States)

    Apinyawasisuk, Supanut; Zhou, Xinkai; Tian, Jack J; Garcia, Giancarlo A; Karanjia, Rustum; Sadun, Alfredo A

    2017-09-01

    Forced eyelid closure test (FECT) is a clinical screening test developed from the original Cogan lid twitch (CLT) sign to assist in the diagnosis of ocular myasthenia gravis (OMG), We evaluated the sensitivity and specificity of FECT compared with CLT and benchmarked to standard diagnostic tests. This study was a retrospective chart review of 48 patients using electronic medical records of those that presented with ptosis and/or diplopia at Doheny Eye Institute, University of California, Los Angeles between February 2015 and April 2016. Patients without FECT testing were excluded. FECT and CLT results, and final diagnosis were recorded. To perform FECT, the patient was asked to squeeze his or her eyelids shut for 5-10 seconds then open quickly and fixate in primary position. The excessive upward overshoot of eyelids movement indicated a positive FECT. The test was performed by a neuro-ophthalmologist before establishing the diagnosis. Patients who had equivocal test results and/or inconclusive final diagnosis were excluded. Of the 48 patients studied, 18 patients (37.5%) had positive FECT; 15 of whom had a final diagnosis of OMG (83.3%). Of the 30 patients with negative FECT, 1 had OMG (3.3%). Of the 48 patients, 35 patients also had a documented CLT result (72.9%). CLT was positive in 11 of these 35 patients (31.4%), and 9 of these 11 had OMG (81.8%). Of the 24 patients with negative CLT, 2 of them had OMG (8.3%). Sensitivity and specificity of FECT were 94% and 91% (joint 95% confidence region: sensitivity × specificity = [0.70, 1] × [0.75, 1]). The relative true-positive fraction (rTPF) between FECT and CLT was 1.15; the relative false-positive fraction was 1.31. FECT is a simple clinical screening test with good sensitivity and specificity for OMG.

  5. Risk-benefit analysis for mass screening of breast cancer utilizing mammography as a screening test

    International Nuclear Information System (INIS)

    Iinuma, T.A.; Tateno, Yukio

    1989-01-01

    Incidence of breast cancers in Japanese women is increasing steadily. Mass screening of breast cancer was started in Japan under auspices of Adult Health Promotion Act of the Japanese Government from 1987. As the first screening method, the palpation of breasts is employed at present, but it is expected to be replaced by the mammography. In this report, the risk-benefit analysis is presented between risk of breast carcinogenesis due to radiation and benefit of mass screening of breast cancer. The benefit of mass screening is taken as the net elongation of average life expectancy of women due to survival from breast cancers. The risk of mammography is taken as the net loss of average life expectancy of women due to breast carcinogenesis. In the latter, the latency time and plateau period of radiation carcinogenesis were taken into consideration in the calculation. The results show that the ages at which the benefit and risk become equal are between 30 and 35 years old when dose equivalent of mammography is between 10 and 20 mSv, that are conventionally used. However, the critical age will be reduced to 20 years old if the dose equivalent becomes 1 mSv. Therefore, it is strongly recommended that a low dose mammographic system should be developed in order to achieve 1 mSv for the mass screening of breast cancer of Japanese women. In author's opinion, this is quite feasible by employing a new digital radiography with imaging plate. (author)

  6. Experiences with a self-test for Dutch breast screening radiologists: lessons learnt

    NARCIS (Netherlands)

    Timmers, J. M. H.; Verbeek, A. L. M.; Pijnappel, R. M.; Broeders, M. J. M.; den Heeten, G. J.

    2014-01-01

    To evaluate a self-test for Dutch breast screening radiologists introduced as part of the national quality assurance programme. A total of 144 radiologists were invited to complete a test-set of 60 screening mammograms (20 malignancies). Participants assigned findings such as location, lesion type

  7. 77 FR 4544 - CPSC Symposium on Phthalates Screening and Testing Methods

    Science.gov (United States)

    2012-01-30

    ... Screening and Testing Methods AGENCY: Consumer Product Safety Commission. ACTION: Notice. SUMMARY: The... symposium on phthalates screening and testing methods. The symposium will be held at the CPSC's National... submit comments, identified by Docket No. CPSC-2012-0008, by any of the following methods: Electronic...

  8. Willingness to take a screening test for colorectal cancer: a community-based survey in Malaysia.

    Science.gov (United States)

    Naing, Cho; Jun, Yip Kar; Yee, Wai Mun; Waqiyuddin, Syazana J D B T; Lui, Lau Chiew; Shaung, Ooi Yin; Haw, Fong Jenn

    2014-03-01

    The aims of the study were (i) to determine the knowledge and perceptions of colorectal cancer (CRC), (ii) to explore the willingness of the study population to take a screening test for CRC, and (iii) to identify factors affecting the willingness to take a screening test for CRC. A cross-sectional survey was carried out in a semiurban town in Malaysia using a pretested structured questionnaire. Descriptive statistics were determined for all important variables. A binary logistic regression model was introduced to identify independent predictors of the willingness to take a screening test. Factors influencing willingness were explored according to the constructs of the health belief model. Of the 256 respondents who had heard about CRC, the majority were aware of altered bowel habits (67.3%) or the presence of blood in stool or rectal bleeding (63.4%) as the warning symptoms. Although 38% of the respondents knew of colonoscopy as the screening test, 22% were not aware of any screening test for CRC. A majority (77.4%) showed willingness to take a screening test for CRC. In the multivariate analysis, 'having family or friends with history of CRC' and 'self-perceived risk' were the two significant variables for predicting the acceptance of CRC screening among the study population. Findings suggested that the respondents' knowledge of the CRC screening test was inadequate, albeit a high proportion expressed their intention to take screening tests. Health education on the CRC addressing available screening tests and the benefits of early screening for CRC should be scaled up.

  9. Abnormal ovarian cancer screening test result: women's informational, psychological and practical needs.

    Science.gov (United States)

    Ryan, Patricia Y; Graves, Kristi D; Pavlik, Edward J; Andrykowski, Michael A

    2007-01-01

    Considerable effort has been devoted to the identification of cost-effective approaches to screening for ovarian cancer (OC). Transvaginal ultrasound (TVS) is one such screening approach. Approximately 5-7% of routine TVS screening tests yield abnormal results. Some women experience significant distress after receipt of an abnormal TVS screening test. Four focus groups provided in-depth, qualitative data regarding the informational, psychological, and practical needs of women after the receipt of an abnormal TVS result. Through question and content analytic procedures, we identified four themes: anticipation, emotional response, role of the screening technician, and impact of prior cancer experiences. Results provide initial guidance toward development of interventions to promote adaptive responses after receipt of an abnormal cancer screening test result.

  10. The King–Devick test for sideline concussion screening in collegiate football

    Directory of Open Access Journals (Sweden)

    Danielle F. Leong

    2015-04-01

    Conclusions: The data show worsening of K–D test scores following concussion further supporting utility of the K–D test as an objective, reliable and effective sideline visual screening tool to help identify athletes with concussion.

  11. Screening for gestational diabetes: examining a breakfast meal test

    African Journals Online (AJOL)

    In current literature both universal and selective screening are still ... One of the central issues that has received less attention is the ... The recorded information included the type of food, ... Body mass index (BMI) at booking > 40 kg/m2.

  12. Mammography and Other Screening Tests for Breast Problems

    Science.gov (United States)

    ... young age; and a history of high-risk breast biopsy results. Women without these risk factors are at ... on when and how often you will have breast screening. Glossary Benign: Not cancer. Biopsy: A minor surgical procedure to remove a small ...

  13. Validating a dance-specific screening test for balance: preliminary results from multisite testing.

    Science.gov (United States)

    Batson, Glenna

    2010-09-01

    Few dance-specific screening tools adequately capture balance. The aim of this study was to administer and modify the Star Excursion Balance Test (oSEBT) to examine its utility as a balance screen for dancers. The oSEBT involves standing on one leg while lightly targeting with the opposite foot to the farthest distance along eight spokes of a star-shaped grid. This task simulates dance in the spatial pattern and movement quality of the gesturing limb. The oSEBT was validated for distance on athletes with history of ankle sprain. Thirty-three dancers (age 20.1 +/- 1.4 yrs) participated from two contemporary dance conservatories (UK and US), with or without a history of lower extremity injury. Dancers were verbally instructed (without physical demonstration) to execute the oSEBT and four modifications (mSEBT): timed (speed), timed with cognitive interference (answering questions aloud), and sensory disadvantaging (foam mat). Stepping strategies were tracked and performance strategies video-recorded. Unlike the oSEBT results, distances reached were not significant statistically (p = 0.05) or descriptively (i.e., shorter) for either group. Performance styles varied widely, despite sample homogeneity and instructions to control for strategy. Descriptive analysis of mSEBT showed an increased number of near-falls and decreased timing on the injured limb. Dancers appeared to employ variable strategies to keep balance during this test. Quantitative analysis is warranted to define balance strategies for further validation of SEBT modifications to determine its utility as a balance screening tool.

  14. A Novel Tool for High-Throughput Screening of Granulocyte-Specific Antibodies Using the Automated Flow Cytometric Granulocyte Immunofluorescence Test (Flow-GIFT

    Directory of Open Access Journals (Sweden)

    Xuan Duc Nguyen

    2011-01-01

    Full Text Available Transfusion-related acute lung injury (TRALI is a severe complication related with blood transfusion. TRALI has usually been associated with antibodies against leukocytes. The flow cytometric granulocyte immunofluorescence test (Flow-GIFT has been introduced for routine use when investigating patients and healthy blood donors. Here we describe a novel tool in the automation of the Flow-GIFT that enables a rapid screening of blood donations. We analyzed 440 sera from healthy female blood donors for the presence of granulocyte antibodies. As positive controls, 12 sera with known antibodies against anti-HNA-1a, -b, -2a; and -3a were additionally investigated. Whole-blood samples from HNA-typed donors were collected and the test cells isolated using cell sedimentation in a Ficoll density gradient. Subsequently, leukocytes were incubated with the respective serum and binding of antibodies was detected using FITC-conjugated antihuman antibody. 7-AAD was used to exclude dead cells. Pipetting steps were automated using the Biomek NXp Multichannel Automation Workstation. All samples were prepared in the 96-deep well plates and analyzed by flow cytometry. The standard granulocyte immunofluorescence test (GIFT and granulocyte agglutination test (GAT were also performed as reference methods. Sixteen sera were positive in the automated Flow-GIFT, while five of these sera were negative in the standard GIFT (anti—HNA 3a, n = 3; anti—HNA-1b, n = 1 and GAT (anti—HNA-2a, n = 1. The automated Flow-GIFT was able to detect all granulocyte antibodies, which could be only detected in GIFT in combination with GAT. In serial dilution tests, the automated Flow-GIFT detected the antibodies at higher dilutions than the reference methods GIFT and GAT. The Flow-GIFT proved to be feasible for automation. This novel high-throughput system allows an effective antigranulocyte antibody detection in a large donor population in order to prevent TRALI due to transfusion of

  15. A novel tool for high-throughput screening of granulocyte-specific antibodies using the automated flow cytometric granulocyte immunofluorescence test (Flow-GIFT).

    Science.gov (United States)

    Nguyen, Xuan Duc; Dengler, Thomas; Schulz-Linkholt, Monika; Klüter, Harald

    2011-02-03

    Transfusion-related acute lung injury (TRALI) is a severe complication related with blood transfusion. TRALI has usually been associated with antibodies against leukocytes. The flow cytometric granulocyte immunofluorescence test (Flow-GIFT) has been introduced for routine use when investigating patients and healthy blood donors. Here we describe a novel tool in the automation of the Flow-GIFT that enables a rapid screening of blood donations. We analyzed 440 sera from healthy female blood donors for the presence of granulocyte antibodies. As positive controls, 12 sera with known antibodies against anti-HNA-1a, -b, -2a; and -3a were additionally investigated. Whole-blood samples from HNA-typed donors were collected and the test cells isolated using cell sedimentation in a Ficoll density gradient. Subsequently, leukocytes were incubated with the respective serum and binding of antibodies was detected using FITC-conjugated antihuman antibody. 7-AAD was used to exclude dead cells. Pipetting steps were automated using the Biomek NXp Multichannel Automation Workstation. All samples were prepared in the 96-deep well plates and analyzed by flow cytometry. The standard granulocyte immunofluorescence test (GIFT) and granulocyte agglutination test (GAT) were also performed as reference methods. Sixteen sera were positive in the automated Flow-GIFT, while five of these sera were negative in the standard GIFT (anti-HNA 3a, n = 3; anti-HNA-1b, n = 1) and GAT (anti-HNA-2a, n = 1). The automated Flow-GIFT was able to detect all granulocyte antibodies, which could be only detected in GIFT in combination with GAT. In serial dilution tests, the automated Flow-GIFT detected the antibodies at higher dilutions than the reference methods GIFT and GAT. The Flow-GIFT proved to be feasible for automation. This novel high-throughput system allows an effective antigranulocyte antibody detection in a large donor population in order to prevent TRALI due to transfusion of blood products.

  16. Development and validation of a new cognitive screening test: The Hong Kong Brief Cognitive Test (HKBC).

    Science.gov (United States)

    Chiu, Helen F K; Zhong, Bao-Liang; Leung, Tony; Li, S W; Chow, Paulina; Tsoh, Joshua; Yan, Connie; Xiang, Yu-Tao; Wong, Mike

    2018-07-01

    To develop and examine the validity of a new brief cognitive test with less educational bias for screening cognitive impairment. A new cognitive test, Hong Kong Brief Cognitive Test (HKBC), was developed based on review of the literature, as well as the views of an expert panel. Three groups of subjects aged 65 or above were recruited after written consent: normal older people recruited in elderly centres, people with mild NCD (neurocognitive disorder), and people with major NCD. The brief cognitive test, Mini-Mental State Examination (MMSE) and Montreal Cognitive Assessment Scale (MoCA), were administered to the subjects. The performance of HKBC in differentiating subjects with major NCD, mild NCD, and normal older people were compared with the clinical diagnosis, as well as the MMSE and MoCA scores. In total, 359 subjects were recruited, with 99 normal controls, 132 subjects with major NCD, and 128 with mild NCD. The mean MMSE, MoCA, and HKBC scores showed significant differences among the 3 groups of subjects. In the receiving operating characteristic curve analysis of the HKBC in differentiating normal subjects from those with cognitive impairment (mild NCD + major NCD), the area under the curve was 0.955 with an optimal cut-off score of 21/22. The performances of MMSE and MoCA in differentiating normal from cognitively impaired subjects are slightly inferior to the HKBC. The HKBC is a brief instrument useful for screening cognitive impairment in older adults and is also useful in populations with low educational level. Copyright © 2018 John Wiley & Sons, Ltd.

  17. Autofluorescence: A screening test for mycotic infection in tissues

    Directory of Open Access Journals (Sweden)

    Rao Shalinee

    2008-04-01

    Full Text Available Fungal infection is a major health concern as the clinical features are not very distinctive. Lack of rapid diagnostic techniques results in delay in diagnosis, which may even culminate in a fatal outcome. The fact that many pathogenic fungal organisms autofluoresce in hematoxylin and eosin (H and E-stained sections under ultraviolet illumination led us to evaluate the role of autofluorescence as a rapid screening technique for fungal infections. The aim of the present study was to assess the value of autofluorescence as a screening method for detecting fungi on tissue sections and to compare the results of autofluorescence with conventional histochemical stains for fungi. Hematoxylin and eosin-stained slides of mycotic lesions were examined under fluorescent microscope and the findings were compared with results of Gomori′s methenamine silver and periodic acid-Schiff stains. We found fungal autofluorescence in 63 out of 64 cases studied, with a sensitivity of 97.8% and specificity of 100% in comparison with fungal stains. This was statistically significant (P < 0.05. We conclude that autofluorescence can be used as a rapid screening method for identification of fungi in tissue sections as it does not require any other specialized staining procedure

  18. The persistence of hepatitis C virus transmission risk in China despite serologic screening of blood donations.

    Science.gov (United States)

    Wang, Jingxing; Liu, Jing; Huang, Yi; Wright, David J; Li, Julin; Zhou, Zhongmin; He, Weilan; Yang, Tonghan; Yao, Fuzhu; Zhu, Xiangming; Wen, Guoxin; Bi, Xinhong; Tiemuer, Mei-hei-li; Wen, Xiuqiong; Huang, Mei; Cao, Ru'an; Yun, Zhongqiao; Lü, Yunlai; Ma, Hongli; Guo, Nan; Yu, Qilu; Ness, Paul; Shan, Hua

    2013-10-01

    A total of 2%-2.9% of the population in China is infected with hepatitis C virus (HCV). This study estimated the prevalence and incidence of HCV among Chinese blood donors. We examined whole blood and apheresis platelet donations at five Chinese blood centers in 2008 to 2010. All donations were screened using two rounds of testing for alanine aminotransferase, antibody to human immunodeficiency virus Types 1 and 2, hepatitis B surface antigen, anti-HCV, and syphilis. Screening reactivity is defined by a reactive result in one or both rounds of screening tests. Confirmatory tests (Ortho third-generation HCV enzyme immunoassay, Johnson & Johnson) were performed on anti-HCV screening-reactive samples. Confirmatory positive rates among first-time donors (prevalence) and repeat donors (incidence) were calculated by blood center and demographic categories. Donor characteristics associated with HCV confirmatory status among first-time donors were examined using trend test and multivariable logistic regression analysis. Among 821,314 donations, 40% came from repeat donors. The overall anti-HCV screening-reactive rate was 0.48%. Estimated HCV prevalence was 235 per 100,000 first-time donors; incidence was 10 per 100,000 person-years in repeat donors. In multivariable logistic regression analysis, first-time donors older than 25 years displayed higher HCV prevalence than the younger donors. Less education is associated with higher HCV prevalence. Donors 26 to 35 years old and those above 45 years displayed the highest incidence rate. High prevalence and incidence in donors indicate high residual risks for transfusion-transmitted HCV in Chinese patients. Implementation of minipool nucleic acid testing in routine donation screening may prevent a substantial number of transfusion-transmitted HCV infections. © 2013 American Association of Blood Banks.

  19. Donor testing and risk: current prevalence, incidence, and residual risk of transfusion-transmissible agents in US allogeneic donations.

    Science.gov (United States)

    Zou, Shimian; Stramer, Susan L; Dodd, Roger Y

    2012-04-01

    Over the past 20 years, there has been a major increase in the safety of the blood supply, as demonstrated by declining rates of posttransfusion infection and reductions in estimated residual risk for such infections. Reliable estimates of residual risk have been possible within the American Red Cross system because of the availability of a large amount of reliable and consistent data on donations and infectious disease testing results. Among allogeneic blood donations, the prevalence rates of infection markers for hepatitis C virus (HCV) and hepatitis B virus have decreased over time, although rates for markers of human immunodeficiency virus (HIV) and human T-cell lymphotropic virus did not. The incidence (/100 000 person-years) of HIV and HCV among repeat donors showed apparent increases from 1.55 and 1.89 in 2000 through 2001 to 2.16 and 2.98 in 2007 through 2008. These observed fluctuations confirm the need for continuous monitoring and evaluation. The residual risk of HIV, HCV, and human T-cell lymphotropic virus among all allogeneic donations is currently below 1 per 1 million donations, and that of hepatitis B surface antigen is close to 1 per 300 000 donations. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Ab initio and density functional theoretical design and screening of model crown ether based ligand (host) for extraction of lithium metal ion (guest): effect of donor and electronic induction.

    Science.gov (United States)

    Boda, Anil; Ali, Sk Musharaf; Rao, Hanmanth; Ghosh, Sandip K

    2012-08-01

    The structures, energetic and thermodynamic parameters of model crown ethers with different donor, cavity and electron donating/ withdrawing functional group have been determined with ab initio MP2 and density functional theory in gas and solvent phase. The calculated values of binding energy/ enthalpy for lithium ion complexation are marginally higher for hard donor based aza and oxa crown compared to soft donor based thia and phospha crown. The calculated values of binding enthalpy for lithium metal ion with 12C4 at MP2 level of theory is in good agreement with the available experimental result. The binding energy is altered due to the inductive effect imparted by the electron donating/ withdrawing group in crown ether, which is well correlated with the values of electron transfer. The role of entropy for extraction of hydrated lithium metal ion by different donor and functional group based ligand has been demonstrated. The HOMO-LUMO gap is decreased and dipole moment of the ligand is increased from gas phase to organic phase because of the dielectric constant of the solvent. The gas phase binding energy is reduced in solvent phase as the solvent molecules weaken the metal-ligand binding. The theoretical values of extraction energy for LiCl salt from aqueous solution in different organic solvent is validated by the experimental trend. The study presented here should contribute to the design of model host ligand and screening of solvent for metal ion recognition and thus can contribute in planning the experiments.

  1. Knowledge and attitude of women regarding breast cancer screening tests in Eastern Iran.

    Science.gov (United States)

    Izanloo, Azra; Ghaffarzadehgan, Kamran; Khoshroo, Fahimeh; Erfani Haghiri, Maryam; Izanloo, Sara; Samiee, Mohadeseh; Tabatabaei, Alireza; Mirshahi, Azadeh; Fakoor, Morteza; Moghadam, Najmeh Jafari; Sadrzadeh, Sayyed Majid

    2018-01-01

    According to recent statistics, there has been a rapid growth of breast cancer in developing countries. Thus, early detection is essential. This study is based on the perception of people in the Northeast of Iran regarding breast cancer screening. In a cross-sectional study, 1469 women were selected randomly in the period from April to November 2016. The study population consisted of women or their companions referring to outpatient clinics or people in public urban areas who filled out a breast cancer screening questionnaire in an interview. The patients' age was in the range of 14 to 84 years (mean = 38.8). More than 84% of interviewees were not informed of breast cancer and screening tests. The main reasons mentioned by patients for their failure to do screening tests was 'absence of any symptom or problem' and 'they did not think it was necessary'.There was not a significant difference between income level, marital status and knowledge of people about breast cancer screening tests (P > 0.05). However, employment, education level and family history had a positive effect on people's awareness of breast cancer and its screening tests (P economic classes was the main barrier to breast cancer screening. In this regard, organizing training programs by physicians and the media can help raise screening rates.

  2. The impact of screening-test negative samples not enumerated by MPN

    DEFF Research Database (Denmark)

    Corbellini, Luis Gustavo; Ribeiro Duarte, Ana Sofia; de Knegt, Leonardo

    2015-01-01

    that includes false negative results from the screening, and a third that considers the entire data set. The relative sensitivity of the screening test was also calculated assuming as gold standard samples with confirmed Salmonella. Salmonella was confirmed by a reference laboratory in 29 samples either...

  3. Cost-effectiveness of one versus two sample faecal immunochemical testing for colorectal cancer screening.

    Science.gov (United States)

    Goede, S Lucas; van Roon, Aafke H C; Reijerink, Jacqueline C I Y; van Vuuren, Anneke J; Lansdorp-Vogelaar, Iris; Habbema, J Dik F; Kuipers, Ernst J; van Leerdam, Monique E; van Ballegooijen, Marjolein

    2013-05-01

    The sensitivity and specificity of a single faecal immunochemical test (FIT) are limited. The performance of FIT screening can be improved by increasing the screening frequency or by providing more than one sample in each screening round. This study aimed to evaluate if two-sample FIT screening is cost-effective compared with one-sample FIT. The MISCAN-colon microsimulation model was used to estimate costs and benefits of strategies with either one or two-sample FIT screening. The FIT cut-off level varied between 50 and 200 ng haemoglobin/ml, and the screening schedule was varied with respect to age range and interval. In addition, different definitions for positivity of the two-sample FIT were considered: at least one positive sample, two positive samples, or the mean of both samples being positive. Within an exemplary screening strategy, biennial FIT from the age of 55-75 years, one-sample FIT provided 76.0-97.0 life-years gained (LYG) per 1000 individuals, at a cost of € 259,000-264,000 (range reflects different FIT cut-off levels). Two-sample FIT screening with at least one sample being positive provided 7.3-12.4 additional LYG compared with one-sample FIT at an extra cost of € 50,000-59,000. However, when all screening intervals and age ranges were considered, intensifying screening with one-sample FIT provided equal or more LYG at lower costs compared with two-sample FIT. If attendance to screening does not differ between strategies it is recommended to increase the number of screening rounds with one-sample FIT screening, before considering increasing the number of FIT samples provided per screening round.

  4. The Clinical and Economic Benefits of Co-Testing Versus Primary HPV Testing for Cervical Cancer Screening: A Modeling Analysis.

    Science.gov (United States)

    Felix, Juan C; Lacey, Michael J; Miller, Jeffrey D; Lenhart, Gregory M; Spitzer, Mark; Kulkarni, Rucha

    2016-06-01

    Consensus United States cervical cancer screening guidelines recommend use of combination Pap plus human papillomavirus (HPV) testing for women aged 30 to 65 years. An HPV test was approved by the Food and Drug Administration in 2014 for primary cervical cancer screening in women age 25 years and older. Here, we present the results of clinical-economic comparisons of Pap plus HPV mRNA testing including genotyping for HPV 16/18 (co-testing) versus DNA-based primary HPV testing with HPV 16/18 genotyping and reflex cytology (HPV primary) for cervical cancer screening. A health state transition (Markov) model with 1-year cycling was developed using epidemiologic, clinical, and economic data from healthcare databases and published literature. A hypothetical cohort of one million women receiving triennial cervical cancer screening was simulated from ages 30 to 70 years. Screening strategies compared HPV primary to co-testing. Outcomes included total and incremental differences in costs, invasive cervical cancer (ICC) cases, ICC deaths, number of colposcopies, and quality-adjusted life years for cost-effectiveness calculations. Comprehensive sensitivity analyses were performed. In a simulation cohort of one million 30-year-old women modeled up to age 70 years, the model predicted that screening with HPV primary testing instead of co-testing could lead to as many as 2,141 more ICC cases and 2,041 more ICC deaths. In the simulation, co-testing demonstrated a greater number of lifetime quality-adjusted life years (22,334) and yielded $39.0 million in savings compared with HPV primary, thereby conferring greater effectiveness at lower cost. Model results demonstrate that co-testing has the potential to provide improved clinical and economic outcomes when compared with HPV primary. While actual cost and outcome data are evaluated, these findings are relevant to U.S. healthcare payers and women's health policy advocates seeking cost-effective cervical cancer screening

  5. Fluorescent screens and image processing for the APS linac test stand

    International Nuclear Information System (INIS)

    Berg, W.; Ko, K.

    1992-01-01

    A fluorescent screen was used to monitor relative beam position and spot size of a 56-MeV electron beam in the linac test stand. A chromium doped alumina ceramic screen inserted into the beam was monitored by a video camera. The resulting image was captured using a frame grabber and stored into memory. Reconstruction and analysis of the stored image was performed using PV-WAVE. This paper will discuss the hardware and software implementation of the fluorescent screen and imaging system. Proposed improvements for the APS linac fluorescent screens and image

  6. A virtual test of screening technology based on the AGEIA PhysX

    Energy Technology Data Exchange (ETDEWEB)

    Ai-min Li; Rui-ling Lv; Chu-sheng Liu [China University of Mining and Technology, Xuzhou (China). School of Mechanical and Electrical Engineering

    2008-06-15

    The authors have created a virtual test of vibration particle-screening using Autodesk's 3ds Max software, the MAXScript scripting language and the AGEIA PhysX physics processing unit (PPU). The affect of various parameters on screening efficiency were modeled. The parameters included vibration amplitude, frequency and direction. The length and inclination of the vibrating surface were also varied. The virtual experiment is in basic agreement with results predicted from screening theory. This shows that the virtual screener can be used for preliminary investigations and the results used to evaluate screen design. In addition it can help with theoretical research. 11 refs., 7 figs., 7 tabs.

  7. On the Estimation of Disease Prevalence by Latent Class Models for Screening Studies Using Two Screening Tests with Categorical Disease Status Verified in Test Positives Only

    Science.gov (United States)

    Chu, Haitao; Zhou, Yijie; Cole, Stephen R.; Ibrahim, Joseph G.

    2010-01-01

    Summary To evaluate the probabilities of a disease state, ideally all subjects in a study should be diagnosed by a definitive diagnostic or gold standard test. However, since definitive diagnostic tests are often invasive and expensive, it is generally unethical to apply them to subjects whose screening tests are negative. In this article, we consider latent class models for screening studies with two imperfect binary diagnostic tests and a definitive categorical disease status measured only for those with at least one positive screening test. Specifically, we discuss a conditional independent and three homogeneous conditional dependent latent class models and assess the impact of misspecification of the dependence structure on the estimation of disease category probabilities using frequentist and Bayesian approaches. Interestingly, the three homogeneous dependent models can provide identical goodness-of-fit but substantively different estimates for a given study. However, the parametric form of the assumed dependence structure itself is not “testable” from the data, and thus the dependence structure modeling considered here can only be viewed as a sensitivity analysis concerning a more complicated non-identifiable model potentially involving heterogeneous dependence structure. Furthermore, we discuss Bayesian model averaging together with its limitations as an alternative way to partially address this particularly challenging problem. The methods are applied to two cancer screening studies, and simulations are conducted to evaluate the performance of these methods. In summary, further research is needed to reduce the impact of model misspecification on the estimation of disease prevalence in such settings. PMID:20191614

  8. Seropositivity of TTIs among blood donors in Hail, Saudi Arabia, from 2014 to 2015

    Directory of Open Access Journals (Sweden)

    Yousef Abd El Galil Ahmed Sarah

    2016-02-01

    Full Text Available Objective: To detect the seropositivity of transfusion transmitted infections among healthy blood donors in Hail Region, Saudi Arabia. Methods: In the study, about 361 blood donors from different nationalities and ages were tested. Serum samples were collected and tested by ELISA for detection of HIV, HTLV-I/II, hepatitis B virus, syphilis and hepatitis C virus (HCV. Results: Out of 361 donors, 26 were found to be positive for HCV in a percentage of 7.2% while 17 (4.7% of them were infected with HIV. There were eight donors infected with HTLV-I/II, and three donors infected with syphilis. Hepatitis B surface antigen was detected in 10% of donors while hepatitis B surface antibody and hepatitis B core antibody were positive in thirty-one blood donors. Conclusions: The obtained data revealed that the seropositivity of hepatitis B virus, HCV, syphilis, HTLV-I/II, and HIV in Hail Region during the period under study were 8.6%, 7.2%, 4.7%, 2.2% and 0.8%, respectively. It is recommended to continue screening blood donors with highly specific and sensitive tests, to counsel donors who are positive to transfusion transmitted infections.

  9. Immunochemical faecal occult blood test for colorectal cancer screening: a systematic review.

    Science.gov (United States)

    Syful Azlie, M F; Hassan, M R; Junainah, S; Rugayah, B

    2015-02-01

    A systematic review on the effectiveness and costeffectiveness of Immunochemical faecal occult IFOBT for CRC screening was carried out. A total of 450 relevant titles were identified, 41 abstracts were screened and 18 articles were included in the results. There was fair level of retrievable evidence to suggest that the sensitivity and specificity of IFOBT varies with the cut-off point of haemoglobin, whereas the diagnostic accuracy performance was influenced by high temperature and haemoglobin stability. A screening programme using IFOBT can be effective for prevention of advanced CRC and reduced mortality. There was also evidence to suggest that IFOBT is cost-effective in comparison with no screening, whereby a two-day faecal collection method was found to be costeffective as a means of screening for CRC. Based on the review, quantitative IFOBT method can be used in Malaysia as a screening test for CRC. The use of fully automated IFOBT assay would be highly desirable.

  10. Clinical experience from Thailand noninvasive prenatal testing as screening tests for trisomies 21, 18 and 13 in 4736 pregnancies

    DEFF Research Database (Denmark)

    Manotaya, S.; Xu, H.; Uerpairojkit, B.

    2016-01-01

    -risk pregnancies, either with advanced maternal age or positive serum biochemical tests, and 1889 low-risk pregnancies without conventional indications; 99.9% (4732/4736) of the participants with a median maternal age of 35years old received reports, and 1.3% (63/4732) were classified as test positive, including...... testing (NIPT) has enabled efficient and accurate screening for T21, T18 and T13. Various professional societies suggested that NIPT could be considered as a second-tier screening test for women at high risk for aneuploidy. What does this study add? This study reports the performance of NIPT...

  11. Knowledge of prenatal screening and psychological management of test decisions

    DEFF Research Database (Denmark)

    Dahl, Katja; Hvidman, Lone; Jørgensen, Finn Stener

    2010-01-01

    well-being respectively worries in pregnancy. METHODS: A population-based cross-sectional study with 6,427 pregnant women consecutively included before the time of a nuchal translucency scan. Participants were recruited from three Danish obstetric departments offering prenatal screening free of charge....... The results presented are based on 4,111 pregnant women (64%). Knowledge was measured by 15 knowledge questions. The primary outcomes were measured by use of pre-existing validated scales i.e. The Decisional Conflict Scale, the WHO well-being index, and the Cambridge Worry Scale. Associations were analysed...... associated with higher levels of well-being (adjusted linear coefficient 0.51 (0.26 to 0.75), p

  12. HEPATITIS B PREVALENCE AMONG BLOOD DONORS AT A TERTIARY CARE CENTRE IN MYSORE

    Directory of Open Access Journals (Sweden)

    Sreenivas

    2015-02-01

    Full Text Available BACKGROUND: Blood transfusion is an essential element of a health care system. Safety of blood transfusion is of extreme importance in order to avoid any severe morbidity and mortality in the patient. By screening donated blood units, we get a clue of the prevalence of those infections among donor pop ulations and consequently the safety of collected donations. It also gives us an idea of the prevalence of the Transfusion transmissible infections ( TTIs in the community. OBJECTIVES : To find out the sero - prevalence of TTIs namely HBV (Hepatitis B in the blood donor population at MMC&RI, Mysore. To stratify sero prevalence of TTIs based on the age and sex of the donor population . METHODOLOGY: The present study was carried out in the Blood Bank , Mysore Medical College and Research Institute , Mysore during the period from November 2012 to May 2014 among 14075 blood donors. All the samples were screened for hepatitis B surface antigen (HBsAg by ELISA method . RESULTS : Out of a total of 14075 blood donors , a total of 103 tested positive for TTIs . 94.08% were males and remaining 5.92% were females. A majority of donors were voluntary donors (85.79% and a majority of the donors were between the age group of 18 - 39 years (78.17%. The prevalence rate of HBV in blood donors was 0.73%. The seroprevale nce in voluntary donors was 0.57% and in replacement donors was 1.75 % respectively. CONCLUSION : Voluntary blood donation is safe, compared to replacement as high prevalence of Hepatitis B is observed in replacement donors.

  13. STRATEGIES TO REDUCE OR REPLACE THE USE OF ANIMALS IN THE ENDOCRINE SCREENING AND TESTING PROGRAM.

    Science.gov (United States)

    Abstract: The US Environmental Protection Agency (EPA) is developing a screening and testing program for endocrine disrupting chemicals (EDCs) to detect alterations of hypothalamic-pituitary-gonadal (HPG) function, estrogen, androgen and thyroid hormone synthesis and androgen (AR...

  14. Evaluating the evidence: direct-to-consumer screening tests advertised online.

    Science.gov (United States)

    Lovett, Kimberly M; Mackey, Timothy K; Liang, Bryan A

    2012-09-01

    Unsupervised online direct-to-consumer (DTC) access to medical services has rapidly expanded to medical screening tests, which have not been critically evaluated for their evidence basis. The objective of this study is to identify the scope of online-advertised DTC screening tests, outline the evidence for use of available DTC testing and suggest regulatory reform to address the relevant issues. An observational study of website advertisements, testing services and counselling/follow-up services for DTC testing was conducted. Data were collected from websites between 4 April and 1 June 2011. Each website was assessed for tests offered, advertised indications and availability of counselling/follow-up services. Advertised testing indications were compared with US Preventive Services Task Force recommendations and/or specialty guidelines and categorized as Supported, Against, Insufficient Evidence or No Guidance. Of 20 companies identified as offering DTC screening tests, 95% (19/20) do not clearly offer pretest counselling, post-test counselling and/or test follow-up. One hundred and twenty-seven different tests were identified. Only 19/127 (15%) could be Supported for screening in a target group selected for testing; 38/127 (30%) were given recommendations to avoid use in specific target group(s) selected for testing ('Against recommendations'); 29/127 (23%) had Insufficient Evidence of value, and for 64/127 (50%) No Guidance could be given. Only 4/127 (3%) tests were Supported for general screening use. Virtually all identified medical tests advertised and offered DTC are not recommended for use in screening by evidence-based guidelines. Limited oversight may lead to inaccurate self-diagnosis, treatment and wasted health resources.

  15. Detection of lung cancer through low-dose CT screening (NELSON): a prespecified analysis of screening test performance and interval cancers.

    Science.gov (United States)

    Horeweg, Nanda; Scholten, Ernst Th; de Jong, Pim A; van der Aalst, Carlijn M; Weenink, Carla; Lammers, Jan-Willem J; Nackaerts, Kristiaan; Vliegenthart, Rozemarijn; ten Haaf, Kevin; Yousaf-Khan, Uraujh A; Heuvelmans, Marjolein A; Thunnissen, Erik; Oudkerk, Matthijs; Mali, Willem; de Koning, Harry J

    2014-11-01

    Low-dose CT screening is recommended for individuals at high risk of developing lung cancer. However, CT screening does not detect all lung cancers: some might be missed at screening, and others can develop in the interval between screens. The NELSON trial is a randomised trial to assess the effect of screening with increasing screening intervals on lung cancer mortality. In this prespecified analysis, we aimed to assess screening test performance, and the epidemiological, radiological, and clinical characteristics of interval cancers in NELSON trial participants assigned to the screening group. Eligible participants in the NELSON trial were those aged 50-75 years, who had smoked 15 or more cigarettes per day for more than 25 years or ten or more cigarettes for more than 30 years, and were still smoking or had quit less than 10 years ago. We included all participants assigned to the screening group who had attended at least one round of screening. Screening test results were based on volumetry using a two-step approach. Initially, screening test results were classified as negative, indeterminate, or positive based on nodule presence and volume. Subsequently, participants with an initial indeterminate result underwent follow-up screening to classify their final screening test result as negative or positive, based on nodule volume doubling time. We obtained information about all lung cancer diagnoses made during the first three rounds of screening, plus an additional 2 years of follow-up from the national cancer registry. We determined epidemiological, radiological, participant, and tumour characteristics by reassessing medical files, screening CTs, and clinical CTs. The NELSON trial is registered at www.trialregister.nl, number ISRCTN63545820. 15,822 participants were enrolled in the NELSON trial, of whom 7915 were assigned to low-dose CT screening with increasing interval between screens, and 7907 to no screening. We included 7155 participants in our study, with

  16. Performance of QuantiFERON TB Gold test in detecting latent tuberculosis infection in brain-dead organ donors in Iran: a brief report.

    Science.gov (United States)

    Tabarsi, Payam; Yousefzadeh, Amir; Najafizadeh, Katayoun; Droudinia, Atousa; Bayati, Rouzbeh; Marjani, Majid; Shafaghi, Shadi; Farokhzad, Banafsheh; Javanmard, Pedram; Velayati, Ali Akbar

    2014-11-01

    With regard to the significant morbidity and mortality due to tuberculosis in lung transplant recipients, the identification of brain-dead organ donors with latent tuberculosis by use of the QuantiFERON TB Gold (QFT-G) test may be of help to reduce the risk of TB reactivation and mortality in lung recipients. This study was conducted in the National Research Institute of Tuber-culosis and Lung Diseases (NRITLD) in Iran, from January to March 2013. A total of 38 conse-cutive brain-dead donors, not currently infected with active tuberculosis, were recruited. The medi-cal records of all the study enrollees were reviewed. A whole-blood IFN- release assay (IGRA) in reaction to early secreted antigenic target 6 (ESAT-6), culture filtrate protein 10 (CFP-10), and TB7.7 antigens, was performed and the released Interferon- was measured via enzyme-linked immunosorbent assay (ELISA). The data was analyzed with QFT-G software which was provided by the company. The demographic, characteristics and other variables were entered into SPSS version 11.5. The QFT-G test results of three donors (7.9%) turned out to be positive, negative for 24 donors (63.1%), and indeterminate for 11 cases (28.9%). Our study revealed the potential advantages of QFT-G in lowering the incidence of donor-derived post-transplant tuberculosis among lung recipients. However, a high rate of indeterminate results restricted the performance of QFT-G in this study.

  17. Performance of QuantiFERON TB Gold test in detecting latent tuberculosis infection in brain-dead organ donors in Iran: A brief report

    Directory of Open Access Journals (Sweden)

    Payam Tabarsi

    2014-01-01

    Full Text Available With regard to the significant morbidity and mortality due to tuberculosis in lung transplant recipients, the identification of brain-dead organ donors with latent tuberculosis by use of the QuantiFERON TB Gold (QFT-G test may be of help to reduce the risk of TB reactivation and mortality in lung recipients. This study was conducted in the National Research Institute of Tuber-culosis and Lung Diseases (NRITLD in Iran, from January to March 2013. A total of 38 conse-cutive brain-dead donors, not currently infected with active tuberculosis, were recruited. The medi-cal records of all the study enrollees were reviewed. A whole-blood IFN- release assay (IGRA in reaction to early secreted antigenic target 6 (ESAT-6, culture filtrate protein 10 (CFP-10, and TB7.7 antigens, was performed and the released Interferon- was measured via enzyme-linked immunosorbent assay (ELISA. The data was analyzed with QFT-G software which was provided by the company. The demographic, characteristics and other variables were entered into SPSS version 11.5. The QFT-G test results of three donors (7.9% turned out to be positive, negative for 24 donors (63.1%, and indeterminate for 11 cases (28.9%. Our study revealed the potential advantages of QFT-G in lowering the incidence of donor-derived post-transplant tuberculosis among lung recipients. However, a high rate of indeterminate results restricted the performance of QFT-G in this study.

  18. Hepatitis B core antigen antibody as an indicator of a low grade carrier state for hepatitis B virus in a Saudi Arabian blood donor population.

    Science.gov (United States)

    Bernvil, S S; Andrews, V; Kuhns, M C; McNamara, A L

    1997-03-01

    Blood donor screening for anti-hepatitis B core antigen (anti-HBc) was introduced as a surrogate marker of non-A, non-B hepatitis prior to the availability of a specific test for hepatitis C. In areas endemic for hepatitis B virus (HBV), such as Saudi Arabia, earlier studies indicated that up to 30% of blood donors might disqualify if screened for anti-HBc. The issue was readdressed in a study of 6035 consecutive first-time Saudi national blood donors in an attempt to identify a subgroup of anti-HBc positive donors who might be at high risk of being low grade carriers of HBV. An isolated anti-HBc of high titer in a donor with a low or absent anti-hepatitis B surface antigen (anti-HBsAg) was taken as an indicator of increased risk of a low grade carrier state. Using this algorithm, an additional 125 (2%) donors would disqualify. HBsAg immune complex assays and polymerase chain reaction of donor samples with an isolated anti-HBc identified two donors with immune complexes and two donors with HBV DNA. All four donor samples expressed over 90% neutralization in the anti-HBc supplementary testing, indicating high titer anti-HBc. These findings seem to support the suggested policy of donor exclusion based on the anti-HBc and anti-HBsAg serology as a means to eliminate low grade carriers of HBV in endemic areas without jeopardizing the blood supply.

  19. Screening for mikroalbuminuri med Micral-Test. En semikvantitativ urinstix

    DEFF Research Database (Denmark)

    Jensen, J S; Borch-Johnsen, K; Feldt-Rasmussen, B F

    1993-01-01

    , specificity and diagnostic specificity in detecting microalbuminuria was 92, 58 and 12% respectively. The prevalence of microalbuminuria was 5.6%. In conclusion, the Micral-Test is highly sensitive in detecting microalbuminuria, but at the expense of a relatively high number of false positive tests....

  20. Astrophysical tests of gravity: a screening map of the nearby universe

    Energy Technology Data Exchange (ETDEWEB)

    Cabré, Anna; Vikram, Vinu; Jain, Bhuvnesh [Center for Particle Cosmology, Department of Physics and Astronomy, University of Pennsylvania, 209 South 33rd Street, Philadelphia, PA 19104-6396 (United States); Zhao, Gong-Bo; Koyama, Kazuya, E-mail: annanusca@gmail.com, E-mail: vinu@sas.upenn.edu, E-mail: gong-bo.zhao@port.ac.uk, E-mail: bjain@physics.upenn.edu, E-mail: Kazuya.Koyama@port.ac.uk [Institute of Cosmology and Gravitation, University of Portsmouth, Dennis Sciama Building, Burnaby Road, Portsmouth, PO1 3FX (United Kingdom)

    2012-07-01

    Astrophysical tests of modified gravity theories in the nearby universe have been emphasized recently by Hui 2009 and Jain 2011. A key element of such tests is the screening mechanism whereby general relativity is restored in massive halos or high density environments like the Milky Way. In chameleon theories of gravity, including all f(R) models, field dwarf galaxies may be unscreened and therefore feel an extra force, as opposed to screened galaxies. The first step to study differences between screened and unscreened galaxies is to create a 3D screening map. We use N-body simulations to test and calibrate simple approximations to determine the level of screening in galaxy catalogs. Sources of systematic errors in the screening map due to observational inaccuracies are modeled and their contamination is estimated. We then apply our methods to create a map out to 200 Mpc in the Sloan Digital Sky Survey footprint using data from the Sloan survey and other sources. In two companion papers this map will be used to carry out new tests of gravity using distance indicators and the disks of dwarf galaxies. We also make our screening map publicly available.

  1. Perceived effectiveness of HPV test as a primary screening modality among US providers.

    Science.gov (United States)

    Cooper, Crystale Purvis; Saraiya, Mona

    2015-09-01

    The human papillomavirus (HPV) test, administered alone without the Papanicolaou (Pap) test, was recently recognized as a cervical cancer screening option in the United States by the Society of Gynecologic Oncology and the American Society for Colposcopy and Cervical Pathology, and the Food and Drug Administration has approved an HPV test for primary screening. Surveys of US internists, family practitioners, nurse practitioners, and obstetrician-gynecologists were conducted in 2009 and 2012 to investigate providers' perceptions of the effectiveness of the HPV test administered alone as a population-based screening modality (2009: N=1040, 141-494 per provider group; 2012: N=1039, 155-435 per provider group). The majority in each provider group agreed that the HPV test administered alone is an effective screening modality in 2009 (75.3%-86.1%) and 2012 (79.5%-91.8%), and agreement rose significantly during this time period among family practitioners (χ(2)=15.26, df=1, ptest administered alone is an effective cervical cancer screening modality was widespread among providers in both 2009 and 2012, however implementation of guidelines for screening with the HPV test may be influenced by many other factors including reimbursement and patient preferences. Published by Elsevier Inc.

  2. 77 FR 15101 - Results From Inert Ingredient Test Orders Issued Under EPA's Endocrine Disruptor Screening...

    Science.gov (United States)

    2012-03-14

    ... the selection criteria for endocrine testing under the Safe Drinking Water Act (SDWA). EPA has no...) because the chemicals meet the selection criteria. EPA has no plans to issue further test orders for the... Screening Program (EDSP) and the Federal Food, Drug, and Cosmetic Act (FFDCA). In response to the test...

  3. Comparison of accuracy measures of two screening tests for gestational diabetes mellitus

    NARCIS (Netherlands)

    van Leeuwen, Marsha; Zweers, Egbert J. K.; Opmeer, Brent C.; van Ballegooie, Evert; ter Brugge, Henk G.; de Valk, Harold W.; Mol, Ben W. J.; Visser, Gerard H. A.

    2007-01-01

    OBJECTIVE: To compare the accuracy measures of the random glucose test and the 50-g glucose challenge test as screening tests for gestational diabetes mellitus (GDM). RESEARCH DESIGN AND METHODS: In this prospective cohort study, pregnant women without preexisting diabetes in two perinatal centers

  4. Results from the Dutch speech-in-noise screening test by telephone

    NARCIS (Netherlands)

    Smits, C.H.M.; Houtgast, T.

    2005-01-01

    OBJECTIVE: The objective of the study was to implement a previously developed automatic speech-in-noise screening test by telephone (Smits, Kapteyn, & Houtgast, 2004), introduce it nationwide as a self-test, and analyze the results. DESIGN: The test was implemented on an interactive voice response

  5. Quality evaluation of four hemoglobin screening methods in a blood donor setting along with their comparative cost analysis in an Indian scenario

    Directory of Open Access Journals (Sweden)

    Tondon Rashmi

    2009-01-01

    Full Text Available Background: Despite the wide range of methods available for measurement of hemoglobin, no single technique has emerged as the most appropriate and ideal for a blood donation setup. Materials and Methods: A prospective study utilizing 1014 blood samples was carried out in a blood donation setting for quality evaluation of four methods of hemoglobin estimation along with cost analysis: Hematology cell analyzer (reference, HCS, CuSO4 method and HemoCue. Results: Mean value of HemoCue (mean ± SD = 14.7 ± 1.49 g/dl was higher by 0.24 compared to reference (mean ± SD = 13.8 ± 1.52 g/dl but not statistically significant ( P > 0.05. HemoCue proved to be the best technique (sensitivity 99.4% and specificity 84.4% whereas HCS was most subjective with 25.2% incorrect estimations. CuSO4 proved to be good with 7.9% false results. Comparative cost analysis of each method was calculated to be 35 INR/test for HemoCue, 0.76 INR /test for HCS and 0.06-0.08 INR /test for CuSO4. Conclusion: CuSO4 method gives accurate results, if strict quality control is applied. HemoCue is too expensive to be used as a primary screening method in an economically restricted country like India.

  6. Discrimination indices as screening tests for beta-thalassemic trait.

    Science.gov (United States)

    Ntaios, George; Chatzinikolaou, Anastasia; Saouli, Zoi; Girtovitis, Fotios; Tsapanidou, Maria; Kaiafa, Georgia; Kontoninas, Zisis; Nikolaidou, Androula; Savopoulos, Christos; Pidonia, Ifigenia; Alexiou-Daniel, Stiliani

    2007-07-01

    The two most frequent microcytic anemias are beta-thalassemic trait (beta-TT) and iron deficiency anemia (IDA). Several discrimination indices have been proposed to distinguish between these two conditions. These indices are derived from several simple red blood cell indices, like red blood cell (RBC) count, mean cell volume, and RBC distribution width (RDW), as these are provided by electronic cell counters. The purpose of the study is to examine the diagnostic accuracy of six discrimination indices in the differentiation between IDA and beta-TT. The six discrimination indices that were examined were as follows: Mentzer Index (MI), Green & King Index (G&K), RDW Index (RDWI), England & Fraser Index (E&F), RDW, and RBC count. We calculated these indices on 373 patients (205 men, 168 women) with beta-TT and 120 patients (50 men, 70 women) with IDA, as well as their sensitivity, specificity, positive and negative prognostic value, efficiency, and Youden's index (YI). G&K shows the highest reliability, followed by E&F, RBC count, MI, and RDWI. On the contrary, RDW completely failed to differentiate between IDA and beta-TT. G&K proved to be the most reliable index as it had the highest sensitivity (75.06%), efficiency (80.12%), and YI (70.86%) for the detection of beta-TT. These six discrimination indices cannot be relied on for a safe differential diagnosis between beta-TT and IDA. They do have high specificity, but their sensitivity for the detection of beta-TT is not satisfactory. Consequently, they cannot be used neither as a screening tool for beta-TT because they could result in a significant number of false negative results.

  7. Bartonella spp. bacteremia in blood donors from Campinas, Brazil.

    Directory of Open Access Journals (Sweden)

    Luiza Helena Urso Pitassi

    2015-01-01

    Full Text Available Bartonella species are blood-borne, re-emerging organisms, capable of causing prolonged infection with diverse disease manifestations, from asymptomatic bacteremia to chronic debilitating disease and death. This pathogen can survive for over a month in stored blood. However, its prevalence among blood donors is unknown, and screening of blood supplies for this pathogen is not routinely performed. We investigated Bartonella spp. prevalence in 500 blood donors from Campinas, Brazil, based on a cross-sectional design. Blood samples were inoculated into an enrichment liquid growth medium and sub-inoculated onto blood agar. Liquid culture samples and Gram-negative isolates were tested using a genus specific ITS PCR with amplicons sequenced for species identification. Bartonella henselae and Bartonella quintana antibodies were assayed by indirect immunofluorescence. B. henselae was isolated from six donors (1.2%. Sixteen donors (3.2% were Bartonella-PCR positive after culture in liquid or on solid media, with 15 donors infected with B. henselae and one donor infected with Bartonella clarridgeiae. Antibodies against B. henselae or B. quintana were found in 16% and 32% of 500 blood donors, respectively. Serology was not associated with infection, with only three of 16 Bartonella-infected subjects seropositive for B. henselae or B. quintana. Bartonella DNA was present in the bloodstream of approximately one out of 30 donors from a major blood bank in South America. Negative serology does not rule out Bartonella spp. infection in healthy subjects. Using a combination of liquid and solid cultures, PCR, and DNA sequencing, this study documents for the first time that Bartonella spp. bacteremia occurs in asymptomatic blood donors. Our findings support further evaluation of Bartonella spp. transmission which can occur through blood transfusions.

  8. Bartonella spp. bacteremia in blood donors from Campinas, Brazil.

    Science.gov (United States)

    Pitassi, Luiza Helena Urso; de Paiva Diniz, Pedro Paulo Vissotto; Scorpio, Diana Gerardi; Drummond, Marina Rovani; Lania, Bruno Grosselli; Barjas-Castro, Maria Lourdes; Gilioli, Rovilson; Colombo, Silvia; Sowy, Stanley; Breitschwerdt, Edward B; Nicholson, William L; Velho, Paulo Eduardo Neves Ferreira

    2015-01-01

    Bartonella species are blood-borne, re-emerging organisms, capable of causing prolonged infection with diverse disease manifestations, from asymptomatic bacteremia to chronic debilitating disease and death. This pathogen can survive for over a month in stored blood. However, its prevalence among blood donors is unknown, and screening of blood supplies for this pathogen is not routinely performed. We investigated Bartonella spp. prevalence in 500 blood donors from Campinas, Brazil, based on a cross-sectional design. Blood samples were inoculated into an enrichment liquid growth medium and sub-inoculated onto blood agar. Liquid culture samples and Gram-negative isolates were tested using a genus specific ITS PCR with amplicons sequenced for species identification. Bartonella henselae and Bartonella quintana antibodies were assayed by indirect immunofluorescence. B. henselae was isolated from six donors (1.2%). Sixteen donors (3.2%) were Bartonella-PCR positive after culture in liquid or on solid media, with 15 donors infected with B. henselae and one donor infected with Bartonella clarridgeiae. Antibodies against B. henselae or B. quintana were found in 16% and 32% of 500 blood donors, respectively. Serology was not associated with infection, with only three of 16 Bartonella-infected subjects seropositive for B. henselae or B. quintana. Bartonella DNA was present in the bloodstream of approximately one out of 30 donors from a major blood bank in South America. Negative serology does not rule out Bartonella spp. infection in healthy subjects. Using a combination of liquid and solid cultures, PCR, and DNA sequencing, this study documents for the first time that Bartonella spp. bacteremia occurs in asymptomatic blood donors. Our findings support further evaluation of Bartonella spp. transmission which can occur through blood transfusions.

  9. Evaluating the Zebrafish Embryo Toxicity Test for Pesticide Hazard Screening

    Science.gov (United States)

    Given the numerous chemicals used in society, it is critical to develop tools for accurate and efficient evaluation of potential risks to human and ecological receptors. Fish embryo acute toxicity tests are 1 tool that has been shown to be highly predictive of standard, more reso...

  10. Quantiferon test for tuberculosis screening in sarcoidosis patients

    DEFF Research Database (Denmark)

    Milman, Nils; Søborg, Bolette; Svendsen, Claus Bo

    2011-01-01

    Tumour necrosis factor-alpha (TNF-α) inhibitors have been introduced in the treatment of refractory sarcoidosis. These biologics may reactivate latent tuberculosis infection (LTBI). Despite its known limitations, the tuberculin skin test (TST) is currently used for the diagnosis of LTBI in Danish...

  11. Evaluation of microscopy and rapid diagnostic tests in screening ...

    African Journals Online (AJOL)

    Malaria is a life-threatening disease caused by the protozoa of the genus Plasmodium. Infection of individual is through the bites of infected female Anopheles mosquitoes. This study evaluated the performance of microscopy and rapid diagnostic tests (RDTs) in diagnosing malaria. A total of 400 clinically suspected malaria ...

  12. Impact on colorectal cancer mortality of screening programmes based on the faecal immunochemical test.

    Science.gov (United States)

    Zorzi, Manuel; Fedeli, Ugo; Schievano, Elena; Bovo, Emanuela; Guzzinati, Stefano; Baracco, Susanna; Fedato, Chiara; Saugo, Mario; Dei Tos, Angelo Paolo

    2015-05-01

    Colorectal cancer (CRC) screening programmes based on the guaiac faecal occult blood test (gFOBT) reduce CRC-specific mortality. Several studies have shown higher sensitivity with the faecal immunochemical test (FIT) compared with gFOBT. We carried out an ecological study to evaluate the impact of FIT-based screening programmes on CRC mortality. In the Veneto Region (Italy), biennial FIT-based screening programmes that invited 50-69-year-old residents were introduced in different areas between 2002 and 2009. We compared CRC mortality rates from 1995 to 2011 between the areas where screening started in 2002-2004 (early screening areas (ESA)) and areas that introduced the screening in 2008-2009 (late screening areas (LSA)) using Poisson regression models. We also compared available data on CRC incidence rates (1995-2007) and surgical resection rates (2001-2012). Before the introduction of screening, CRC mortality and incidence rates in the two areas were similar. Compared with 1995-2000, 2006-2011 mortality rates were 22% lower in the ESA than in the LSA (rate ratio (RR)=0.78; 95% CI 0.68 to 0.89). The reduction was larger in women (RR=0.64; CI 0.51 to 0.80) than in men (RR=0.87; CI 0.73 to 1.04). In the ESA, incidence and surgery rates peaked during the introduction of the screening programme and then returned to the baseline (2006-2007 incidence) or dropped below initial values (surgery after 2007). FIT-based screening programmes were associated with a significant reduction in CRC mortality. This effect took place much earlier than reported by gFOBT-based trials and observational studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. Optimisation and assessment of three modern touch screen tablet computers for clinical vision testing.

    Directory of Open Access Journals (Sweden)

    Humza J Tahir

    Full Text Available Technological advances have led to the development of powerful yet portable tablet computers whose touch-screen resolutions now permit the presentation of targets small enough to test the limits of normal visual acuity. Such devices have become ubiquitous in daily life and are moving into the clinical space. However, in order to produce clinically valid tests, it is important to identify the limits imposed by the screen characteristics, such as resolution, brightness uniformity, contrast linearity and the effect of viewing angle. Previously we have conducted such tests on the iPad 3. Here we extend our investigations to 2 other devices and outline a protocol for calibrating such screens, using standardised methods to measure the gamma function, warm up time, screen uniformity and the effects of viewing angle and screen reflections. We demonstrate that all three devices manifest typical gamma functions for voltage and luminance with warm up times of approximately 15 minutes. However, there were differences in homogeneity and reflectance among the displays. We suggest practical means to optimise quality of display for vision testing including screen calibration.

  14. Optimisation and assessment of three modern touch screen tablet computers for clinical vision testing.

    Science.gov (United States)

    Tahir, Humza J; Murray, Ian J; Parry, Neil R A; Aslam, Tariq M

    2014-01-01

    Technological advances have led to the development of powerful yet portable tablet computers whose touch-screen resolutions now permit the presentation of targets small enough to test the limits of normal visual acuity. Such devices have become ubiquitous in daily life and are moving into the clinical space. However, in order to produce clinically valid tests, it is important to identify the limits imposed by the screen characteristics, such as resolution, brightness uniformity, contrast linearity and the effect of viewing angle. Previously we have conducted such tests on the iPad 3. Here we extend our investigations to 2 other devices and outline a protocol for calibrating such screens, using standardised methods to measure the gamma function, warm up time, screen uniformity and the effects of viewing angle and screen reflections. We demonstrate that all three devices manifest typical gamma functions for voltage and luminance with warm up times of approximately 15 minutes. However, there were differences in homogeneity and reflectance among the displays. We suggest practical means to optimise quality of display for vision testing including screen calibration.

  15. Incidence of interval cancers in faecal immunochemical test colorectal screening programmes in Italy.

    Science.gov (United States)

    Giorgi Rossi, Paolo; Carretta, Elisa; Mangone, Lucia; Baracco, Susanna; Serraino, Diego; Zorzi, Manuel

    2018-03-01

    Objective In Italy, colorectal screening programmes using the faecal immunochemical test from ages 50 to 69 every two years have been in place since 2005. We aimed to measure the incidence of interval cancers in the two years after a negative faecal immunochemical test, and compare this with the pre-screening incidence of colorectal cancer. Methods Using data on colorectal cancers diagnosed in Italy from 2000 to 2008 collected by cancer registries in areas with active screening programmes, we identified cases that occurred within 24 months of negative screening tests. We used the number of tests with a negative result as a denominator, grouped by age and sex. Proportional incidence was calculated for the first and second year after screening. Results Among 579,176 and 226,738 persons with negative test results followed up at 12 and 24 months, respectively, we identified 100 interval cancers in the first year and 70 in the second year. The proportional incidence was 13% (95% confidence interval 10-15) and 23% (95% confidence interval 18-25), respectively. The estimate for the two-year incidence is 18%, which was slightly higher in females (22%; 95% confidence interval 17-26), and for proximal colon (22%; 95% confidence interval 16-28). Conclusion The incidence of interval cancers in the two years after a negative faecal immunochemical test in routine population-based colorectal cancer screening was less than one-fifth of the expected incidence. This is direct evidence that the faecal immunochemical test-based screening programme protocol has high sensitivity for cancers that will become symptomatic.

  16. TORCH Screening Test in Pregnant Women of Kirkuk City

    Directory of Open Access Journals (Sweden)

    Hiro M. Obaid

    2017-07-01

    Cytomegalovirus, Rubella and Toxoplasma are prevalent among pregnant women in Kirkuk city and probably they are the causative agents of abortion and infertility found among them, therefore it's better for pregnant woman or those planning to become pregnant to be tested for TORCH infections, and vaccinated against Rubella, Cytomegalovirus, Herpes simplex virus and Toxoplasma to grantee her health  as well as her baby.

  17. The clinical utility of HPV DNA testing in cervical cancer screening strategies.

    Science.gov (United States)

    Bhatla, Neerja; Moda, Nidhi

    2009-09-01

    Cervical cancer continues to be the commonest cause of death among women in developing countries, largely due to the failure to the inability to sustain effective cytology-based screening programs. While this burden may come down following implementation of the human papillomavirus (HPV) vaccine, screening will still be required. HPV DNA testing is a promising new technology for cervical cancer prevention and is the most reproducible of all cervical cancer screening tests. Presently, the two assays most widely used for the detection of genital types are the polymerase chain reaction (PCR) and Hybrid Capture 2 assays (hc2). Rapid, affordable tests are expected to be available soon. HPV DNA testing can be used in a variety of clinical scenarios that include primary screening in women older than 30 yr; as an adjunctive test to cytology; in the triage of women with an equivocal cytologic report, e.g., ASC-US; or for follow-up post-treatment for cervical intraepithelial neoplasia (CIN). HPV DNA testing can also be performed on self-collected samples, which allows screening in remote areas and also in women who refuse gynecologic examination.

  18. Screening for tuberculosis and testing for human immunodeficiency virus in Zambian prisons

    Science.gov (United States)

    Maggard, Katie R; Hatwiinda, Sisa; Harris, Jennifer B; Phiri, Winifreda; Krüüner, Annika; Kaunda, Kaunda; Topp, Stephanie M; Kapata, Nathan; Ayles, Helen; Chileshe, Chisela; Henostroza, German

    2015-01-01

    Abstract Objective To improve the Zambia Prisons Service’s implementation of tuberculosis screening and human immunodeficiency virus (HIV) testing. Methods For both tuberculosis and HIV, we implemented mass screening of inmates and community-based screening of those residing in encampments adjacent to prisons. We also established routine systems – with inmates as peer educators – for the screening of newly entered or symptomatic inmates. We improved infection control measures, increased diagnostic capacity and promoted awareness of tuberculosis in Zambia’s prisons. Findings In a period of 9 months, we screened 7638 individuals and diagnosed 409 new patients with tuberculosis. We tested 4879 individuals for HIV and diagnosed 564 cases of infection. An additional 625 individuals had previously been found to be HIV-positive. Including those already on tuberculosis treatment at the time of screening, the prevalence of tuberculosis recorded in the prisons and adjacent encampments – 6.4% (6428/100 000) – is 18 times the national prevalence estimate of 0.35%. Overall, 22.9% of the inmates and 13.8% of the encampment residents were HIV-positive. Conclusion Both tuberculosis and HIV infection are common within Zambian prisons. We enhanced tuberculosis screening and improved the detection of tuberculosis and HIV in this setting. Our observations should be useful in the development of prison-based programmes for tuberculosis and HIV elsewhere. PMID:25883402

  19. Correlation of Michigan neuropathy screening instrument, United Kingdom screening test and electrodiagnosis for early detection of diabetic peripheral neuropathy.

    Science.gov (United States)

    Fateh, Hamid R; Madani, Seyed Pezhman; Heshmat, Ramin; Larijani, Bagher

    2015-01-01

    Almost half of Diabetic Peripheral Neuropathies (DPNs) are symptom-free. Methods including questionnaires and electrodiagnosis (EDx) can be fruitful for easy reach to early diagnosis, correct treatments of diabetic neuropathy, and so decline of complications for instance diabetic foot ulcer and prevention of high costs. The goal of our study was to compare effectiveness of the Michigan neuropathy screening instrument (MNSI), United Kingdom screening test (UKST) and electrophysiological evaluation in confirming diabetic peripheral neuropathy. One hundred twenty five known diabetes mellitus male and female subjects older than 18 with or without symptoms of neuropathy comprised in this research. All of them were interviewed in terms of demographic data, lipid profile, HbA1C, duration of disease, and history of retinopathy, so examined by Michigan neuropathy screening instrument (MNSI), United Kingdom screening test (UKST), and nerve conduction studies (NCS). The collected data were analyzed by SPSS software 18. One hundred twenty five diabetic patients (70 female, 55 male) were recruited in this study with a mean age of 58.7 ± 10.2, and mean duration of diabetes was 10.17 ± 6.9 years. The mean neuropathy score of MNSI and UKST were 2.3 (1.7) and 4.16 (2.9), respectively. Each instrument detected the peripheral neuropathy in 78 (69 %) and 91 (73 %) of patients, respectively. There was a significant relationship between number of neuropathies and mean of diabetes duration and development of retinopathy in both questionnaire evaluations and NCS. By nerve conduction study, neuropathy was detected in 121 (97 %) diabetic patients were reported in order 15 (12 %) mononeuropathy (as 33 % sensory and 67 % motor neuropathy) and 106 (85 %) polyneuropathy (as 31 % motor and 69 % sensorimotor neuropathy). As regards NCS is an objective, simple, and non-invasive tool and also can determine level of damage and regeneration in peripheral nerves, this study

  20. Cervical human papilloma virus (HPV) DNA primary screening test: Results of a population-based screening programme in central Italy.

    Science.gov (United States)

    Passamonti, Basilio; Gustinucci, Daniela; Giorgi Rossi, Paolo; Cesarini, Elena; Bulletti, Simonetta; Carlani, Angela; Martinelli, Nadia; Broccolini, Massimo; D'Angelo, Valentina; D'Amico, Maria Rosaria; Di Dato, Eugenio; Galeazzi, Paola; Malaspina, Morena; Spita, Nicoletta; Tintori, Beatrice; Giaimo, Maria Donata

    2017-09-01

    Objective To present the results of the first and second round human papilloma virus (HPV)-based screening programme in the Umbria region after three years. Methods From August 2010 to November 2011, the entire female population aged 35-64 in a local health district was invited for HPV testing (HPV-DNA cobas4800 on a liquid-based cytology sample). HPV-negative women were re-invited after three years. For HPV-positive women, a slide was prepared and interpreted. Positive cytologies were referred to colposcopy; negatives were referred to repeat HPV after one year. If HPV was persistently positive, women were referred to colposcopy; if negative, to normal screening. Indicators of the first and second round are compared with those of cytology screening in the same area in the preceding three years. Results Participation was 56.5%, the same as cytology (56.6%). HPV-positivity was 6.4% (396/6272), cytology triage positivity was 35.6%; 251 cytology negative women were referred to one-year HPV retesting, 84.1% complied, and 55.5% were positive. Total colposcopy referral was 4.1%, and for cytology 1%. The detection rate for cervical intraepithelial neoplasia grade 2 or more severe was 10‰, compared with 3.7‰ using cytology. After three years, HPV-positivity was 3.4% (129/3831), overall colposcopy referral was 2.3% (most at one-year follow-up), and detection rate was 0.5/1000. Conclusions The first round detection rate was more than twice that of cytology screening, while colposcopy referral increased fourfold. At the second round, the detection rate decreased dramatically, showing that longer interval and more conservative protocols are needed.

  1. Detection of complex hemoglobinopathies: recommendations on screening and DNA testing

    Directory of Open Access Journals (Sweden)

    E. Baysal

    2011-12-01

    Full Text Available The following recommendations should be taken into account during the evaluation and elucidation of the complex hemoglobinopathies: a in complex hemoglobinopathies performing DNA studies on all family members might be essential; b complex gene-gene interactions offer major diagnostic challenges both at the technical and clinical level; c hematological & DNA analyses must be run in parallel. Some cases may be straight forward but others may require indepth DNA work-up; d co-inheritance of a-thalassemia offers added challenge as it may affect phenotype significantly; e sickle cell anemia (SS, co-inherited with a-thal, can be a phenocopy of Sβ0-thal. The HbA2 increase can be mistaken for Sβ-thal. DNA Sequencing is imperative; f only a selected number of normal MCV, MCH, borderline HbA2 cases must be referred for DNA analysis. However, in certain cases, following hematological and family evaluation, the β and d genes may need to be sequenced; g DNA Sequencing will increasingly become the method of choice for screening and DNA mutation analysis. However, new methods like MLPA-which analyzes gene dosage- must be used more commonly to rule out deletion mutants to avoid false negative sequencing results; h these recommendations should be reviewed every 2-3 years reflecting new methods, new findings and new findings from ethnic groups. 诊断和说明复杂血红蛋白病时,建议考虑以下几点: a)针对复杂的血红蛋白病,有必要对所有家庭成员开展DNA研究;b 复杂的基因-基因交互作用可能使诊断在技术和临床层面上颇受挑战;c 血液和DNA分析须同时进行。 有些病例简单,但另外一些病例可能需要开展深层次的DNA检查;d 由于α型地中海贫血可能严重影响表型,α型地中海贫血的共同继承特征更具挑战;e 共同继承α型地中海贫血的镰状细胞贫血(SS),可以作为Sβ0型地中海贫血的显型。 HbA2增

  2. "Chair Stand Test" as Simple Tool for Sarcopenia Screening in Elderly Women.

    Science.gov (United States)

    Pinheiro, P A; Carneiro, J A O; Coqueiro, R S; Pereira, R; Fernandes, M H

    2016-01-01

    To investigate the association between sarcopenia and "chair stand test" performance, and evaluate this test as a screening tool for sarcopenia in community-dwelling elderly women. Cross-sectional Survey. 173 female individuals, aged ≥ 60 years and living in the urban area of the municipality of Lafaiete Coutinho, Bahia's inland, Brazil. The association between sarcopenia (defined by muscle mass, strength and/or performance loss) and performance in the "chair stand test" was tested by binary logistic regression technique. The ROC curve parameters were used to evaluate the diagnostic power of the test in sarcopenia screening. The significance level was set at 5 %. The model showed that the time spent for the "chair stand test" was positively associated (OR = 1.08; 95% CI = 1.01 - 1.16, p = 0.024) to sarcopenia, indicating that, for each 1 second increment in the test performance, the sarcopenia's probability increased by 8% in elderly women. The cut-off point that showed the best balance between sensitivity and specificity was 13 seconds. The performance of "chair stand test" showed predictive ability for sarcopenia, being an effective and simple screening tool for sarcopenia in elderly women. This test could be used for screening sarcopenic elderly women, allowing early interventions.

  3. Iron deficiency in blood donors

    Directory of Open Access Journals (Sweden)

    Rodolfo Delfini Cançado

    Full Text Available CONTEXT: Blood donation results in a substantial loss of iron (200 to 250 mg at each bleeding procedure (425 to 475 ml and subsequent mobilization of iron from body stores. Recent reports have shown that body iron reserves generally are small and iron depletion is more frequent in blood donors than in non-donors. OBJECTIVE: The aim of this study was to evaluate the frequency of iron deficiency in blood donors and to establish the frequency of iron deficiency in blood donors according to sex, whether they were first-time or multi-time donors, and the frequency of donations per year. DESIGN: From September 20 to October 5, 1999, three hundred blood donors from Santa Casa Hemocenter of São Paulo were studied. DIAGNOSTIC TESTS: Using a combination of biochemical measurements of iron status: serum iron, total iron-binding capacity, transferrin saturation index, serum ferritin and the erythrocyte indices. RESULTS: The frequency of iron deficiency in blood donors was 11.0%, of whom 5.5% (13/237 were male and 31.7% (20/63 female donors. The frequency of iron deficiency was higher in multi-time blood donors than in first-time blood donors, for male blood donors (7.6% versus 0.0%, P < 0.05 and female ones (41.5% versus 18.5%, P < 0.05. The frequency of iron deficiency found was higher among the male blood donors with three or more donations per year (P < 0.05 and among the female blood donors with two or more donations per year (P < 0.05. CONCLUSIONS: We conclude that blood donation is a very important factor for iron deficiency in blood donors, particularly in multi-time donors and especially in female donors. The high frequency of blood donors with iron deficiency found in this study suggests a need for a more accurate laboratory trial, as hemoglobin or hematocrit measurement alone is not sufficient for detecting and excluding blood donors with iron deficiency without anemia.

  4. Estimation of diagnostic performance of dementia screening tests: Mini-Mental State Examination, Mini-Cog, Clock Drawing test and Ascertain Dementia 8 questionnaire.

    Science.gov (United States)

    Yang, Li; Yan, Jing; Jin, Xiaoqing; Jin, Yu; Yu, Wei; Xu, Shanhu; Wu, Haibin; Xu, Ying; Liu, Caixia

    2017-05-09

    Dementia is one of the leading causes of dependence in the elderly. This study was conducted to estimate diagnostic performance of dementia screening tests including Mini-Mental State Examination (MMSE), Mini-Cog, Clock Drawing Test (CDT) and Ascertain Dementia 8 questionnaire (AD8) by Bayesian models. A total of 2015 participants aged 65 years or more in eastern China were enrolled. The four screening tests were administered and scored by specifically trained psychiatrists. The prior information of sensitivity and specificity of every screening test was updated via Bayes' theorem to a posterior distribution. Then the results were compared with the estimation based on National Institute of Aging-Alzheimer's Association criteria (NIA-AA). The diagnostic characteristics of Mini-Cog, including sensitivity, specificity, PPV, NPV, especially the Youden index, performed well, even better than the combinations of several screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests.

  5. [An experimental proficiency test for ability to screen 104 residual pesticides in agricultural products].

    Science.gov (United States)

    Tsumura, Yukari; Ishimitsu, Susumu; Otaki, Kayo; Uchimi, Hiroyuki; Matsumoto, Nobuyuki; Daba, Masaki; Tsuchiya, Tetsu; Ukyo, Masaho; Tonogai, Yasuhide

    2003-10-01

    An experimental proficiency test program for ability to screen 104 residual pesticides in agricultural products has been conducted. Eight Japanese laboratories joined the program. Items tested in the present study were limit of detection, internal proficiency test (self spike) and external proficiency test (blind spike). All 104 pesticides were well detected and recovered from agricultural foods in the internal proficiency test. However, the results of the external proficiency test did not completely agree with those of the internal proficiency tests. After 5 rounds of the blind spike test, the ratio of the number of correctly detected pesticides to that of actually contained ones (49 total) ranged from 65% to 100% among laboratories. The numbers of mistakenly detected pesticides by a laboratory were 0 to 15. Thus, there was a great difference among the laboratories in the ability to screen multiresidual pesticides.

  6. Screen Channel Liquid Acquisition Device Outflow Tests in Liquid Hydrogen

    Science.gov (United States)

    Hartwig, Jason W.; Chato, David J.; McQuillen, J. B.; Vera, J.; Kudlac, M. T.; Quinn, F. D.

    2013-01-01

    This paper presents experimental design and test results of the recently concluded 1-g inverted vertical outflow testing of two 325x2300 full scale liquid acquisition device (LAD) channels in liquid hydrogen (LH2). One of the channels had a perforated plate and internal cooling from a thermodynamic vent system (TVS) to enhance performance. The LADs were mounted in a tank to simulate 1-g outflow over a wide range of LH2 temperatures (20.3 - 24.2 K), pressures (100 - 350 kPa), and flow rates (0.010 - 0.055 kg/s). Results indicate that the breakdown point is dominated by liquid temperature, with a second order dependence on mass flow rate through the LAD. The best performance is always achieved in the coldest liquid states for both channels, consistent with bubble point theory. Higher flow rates cause the standard channel to break down relatively earlier than the TVS cooled channel. Both the internal TVS heat exchanger and subcooling the liquid in the propellant tank are shown to significantly improve LAD performance.

  7. Sero-prevalence of brucellosis among blood donors in Ahvaz, Southwest Iran

    Directory of Open Access Journals (Sweden)

    Abdolhussein Shakurnia

    2014-02-01

    Full Text Available Objective: To identify sero-prevalence of brucellosis among blood donors in Ahvaz city, Southwest Iran. Methods: A total number of 1 450 serum samples from blood donation were collected and were screened for the presence of brucella antibody. Rose Bengal Plate Test, Standard Agglutination Test (SAT, and 2-mercaptoethanol (2ME agglutination were tested in the sample. SAT dilution ≥1/80 and 2ME agglutination ≥1/40 were considered positive. Results: Sero-prevalence of brucellosis among the blood donors was 0.70%, 0.34%, and 0.20% by Rose Bengal Plate Test, SAT, and 2ME respectively. Conclusions: Considering the 1/80 titer of SAT as the criteria of contamination with brucella, routine screening of sero-prevalence of brucella in blood donors is not recommended in this area.

  8. [Human papillomavirus testing in cervical cancer screening at a public health service of Santiago, Chile].

    Science.gov (United States)

    Terrazas, Solana; Ibáñez, Carolina; Lagos, Marcela; Poggi, Helena; Brañes, Jorge; Barriga, María Isabel; Cartagena, Jaime; Núñez, Felipe; González, Francisca; Cook, Paz; Van De Wyngard, Vanessa; Ferreccio, Catterina

    2015-01-01

    Molecular techniques for human papillomavirus (HPV) detection have a good performance as screening tests and could be included in cervical cancer early detection programs. We conducted a population-based trial comparing HPV detection and Papanicolaou as primary screening tests, in a public health service in Santiago, Chile. To describe the experience of implementing this new molecular test and present the main results of the study. Women aged 25 to 64 enrolled in three public health centers were invited to participate. In all women, samples were collected for Papanicolaou and HPV DNA testing, and naked-eye visual inspection of the cervix with acetic acid was performed. Women with any positive screening test were referred to the local area hospital for diagnostic confirmation with colposcopy and biopsy of suspicious lesions. Screening results were obtained for 8265 women, of whom 931 (11.3%) were positive to any test. The prevalence of cervical intraepithelial neoplasia grade 2 or worse (CIN2+) was 1.1%; nine women had invasive cervical cancer. Sensitivities for the detection of CIN2+ were 22.1% (95% confidence interval (CI) 16.4-29.2) for Papanicolaou and 92.7% (95% CI 84.4-96.8) for HPV testing; specificities were 98.9% (95% CI 98.7-99.0) and 92.0% (95% CI 91.4-92.6) respectively. This experience showed that the implementation of a molecular test for cervical cancer screening is not a major challenge in Chile: it was well accepted by both the health team and the participants, and it may improve the effectiveness of the screening program.

  9. Assessment of Prospective Memory – a Validity Study of Memory for Intentions Screening Test

    NARCIS (Netherlands)

    Bezdicek, O.; Raskin, S.A.; Altgassen, A.M.; Ruzicka, E.

    2014-01-01

    Aim: The goal of the present study was to validate the Czech version of the Memory for Intentions (Screening) Test (MIST, 2010). We included standardized testing material, translation of administration and scoring, and assessment of normative data for the MIST in the Czech population. Introduction:

  10. Restriction of human papillomavirus DNA testing in primary cervical screening to women above age 30

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Njor, Sisse H; Lynge, Elsebeth

    2012-01-01

    Cervical screening with human papillomavirus (HPV) testing is less specific for high-grade cervical intraepithelial neoplasia (=CIN3) than cytology. The aim of this systematic review was to determine whether a restriction of HPV testing to women aged at least 30 years would eliminate the problem...

  11. Memory-Context Effects of Screen Color in Multiple-Choice and Fill-In Tests

    Science.gov (United States)

    Prestera, Gustavo E.; Clariana, Roy; Peck, Andrew

    2005-01-01

    In this experimental study, 44 undergraduates completed five computer-based instructional lessons and either two multiplechoice tests or two fill-in-the-blank tests. Color-coded borders were displayed during the lesson, adjacent to the screen text and illustrations. In the experimental condition, corresponding border colors were shown at posttest.…

  12. Noninvasiv prænatal test er et gennembrud inden for prænatal screening

    DEFF Research Database (Denmark)

    Hornstrup, Louise Stig; Ambye, Louise; Sørensen, Steen

    2016-01-01

    Non-invasive prenatal testing is a breakthrough in prenatal screening Non-invasive prenatal testing (NIPT) using cell-free fetal DNA from the peripheral blood of the pregnant woman has become a possibility within recent years, but is not yet implemented in Denmark. NIPT has proven to be very...

  13. Cross-sectional evaluation of an internet-based hearing screening test in an occupational setting

    NARCIS (Netherlands)

    Sheikh Rashid, Marya; Leensen, Monique Cj; de Laat, Jan Apm; Dreschler, Wouter A.

    2017-01-01

    Objectives The Occupational Earcheck (OEC) is an online internet test to detect high-frequency hearing loss for the purposes of occupational hearing screening. In this study, we evaluated the OEC in an occupational setting in order to assess test sensitivity, specificity, and validity. Methods A

  14. Elevated phenylalanine on newborn screening: follow-up testing may reveal undiagnosed galactosaemia.

    Science.gov (United States)

    Shakespeare, Lynette; Downing, Melanie; Allen, Joyce; Casbolt, Ann-Marie; Ellin, Sheila; Maloney, Martin; Race, Gillian; Bonham, Jim

    2010-11-01

    Introduction Newborn screening for phenylketonuria (PKU) can reveal other conditions which lead to an increased blood spot phenylalanine (Phe) concentration. We have investigated the proportion of blood spot samples that gave a positive screen due to clinically significant conditions other than PKU, compared the positive predictive value (PPV) of our referral Phe cut-off with that recommended by the UK Newborn Screening Programme Centre (UKNSPC) (>210 and >240 μmol/L, respectively) and evaluated the effectiveness of reflex testing for galactosaemia using a lower blood spot Phe cut-off concentration of 130 μmol/L. All blood spot samples that screened positive, for an increased Phe concentration, between April 2001 and March 2008, were identified from the records of the Sheffield Newborn Screening Laboratory and the diagnoses noted. In addition, all cases of galactosaemia detected in or notified to our screening laboratory within this time were also examined and the screened Phe concentrations compared. Out of 438,674 babies who were screened, 67 had Phe concentration >210 μmol/L (15 per 100,000). Of these, 40 had PKU or persistent hyperphenylalaninaemia with a Phe concentration identified by screening between 270 and 2350 μmol/L. A further 11 were diagnosed with another clinically significant disorder: galactosaemia (n = 8), biopterin defects (n = 2), tyrosinaemia Type 1 (n = 1). In addition, 16 had transient elevations in Phe. In total, nine cases of galactosaemia were identified, of whom, three had Phe concentrations 240 μmol/L) will not affect the detection rate of classical PKU, but will improve the PPV from 76% to 80%. The use of a lower cut-off (130 μmol/L) for reflex galactosaemia testing enables the timely identification of asymptomatic cases that benefit particularly from early treatment, without prompting any unnecessary clinical referrals or delaying any referrals. This intervention may reduce mortality in this vulnerable group.

  15. High prevalence of HIV p24 antigen among HIV antibody negative prospective blood donors in Ile-Ife, Nigeria.

    Science.gov (United States)

    Japhet, Margaret Oluwatoyin; Adewumi, Moses Olubusuyi; Adesina, Olufisayo Adeyemi; Donbraye, Emmanuel

    2016-01-01

    Blood transfusion service centers in Nigeria screen donated blood for markers of HIV infection using antibody- (Ab) based rapid test and in some centers, positives are re-tested using Ab-based ELISA. Paucity of data exists on p24 antigen prevalence among HIV Ab-negative donors in Nigeria. This study aims at detecting HIV p24 antigen among prospective blood donors in Osun State, Nigeria. Prospective blood donors negative for HIV antibodies using Determine test kit were re-tested using BIORAD GENSCREEN Ultra Ag-Ab ELISA kit, a fourth-generation ELISA kit that detects HIV antibodies/p24 antigen. Of the 169 HIV Ab-negative prospective donors, 10 (5.9%) were positive for HIV p24 antigen and 70% (7/10) of them were in the age range 18-30 years. Results of this study show that blood transfusion is still one of the major routes of HIV transmission in Nigeria and a higher proportion is among youth. Inclusion of p24 antigen testing into the blood donor screening will help reduce transfusion associated HIV in Nigeria if Nucleic Acid Testing (NAT) of all blood donor samples is not affordable; also, HIV enlightenment programs tailored toward youth may help reduce this rate among donors since more young people donate blood in low/middle-income countries than in high-income countries.

  16. [ALAT and viral RNA as risk factors in 68 blood donors with anti-hepatitis C antibodies].

    Science.gov (United States)

    Tullen, E; De Saussure, P; Soulier-Lauper, M

    1993-01-23

    Determine the risk factors in blood donors with anti hepatitis C antibodies (anti-HCV ab) possible liver involvement and evaluation of their infectious potential by a search for viral RNA in blood. Between July 1990 and October 1991, 19,632 blood donors were screened for hepatitis C. Antibodies to HCV were detected in 74 donors (2nd generation ELISA, Abbott). We evaluated the risk factors, determined ALAT levels and looked for circulating RNA virus by amplification of the non-coding region of the viral genome (RTPCR) in 68 of these 74 donors screened. A control was chosen arbitrarily from 103 donors with high ALAT levels, but with no antibodies to HCV nor detectable circulating viral DNA. The prevalence of anti-HCV ab in blood donors in 0.37%. No risk factor was found in 29 donors (43%). Parenteral exposure (former i.v. drug addiction and history of transfusions) was found to be the mode of transmission of hepatitis C in 23 donors (34%). History of NANB jaundice (non-post transfusion) was reported in 1 donor (1%). The remaining 15 donors (22%) were found to have minor risk factors - either isolated or in combination (exposure, tatoos, multiple sexual partners). Former i.v. drug addiction (p = 0.0000006) as well as a history of transfusions (p = 0.0071) are significantly more frequent in the group of donors with antibodies to HCV. None of the 35 sexual partners of the tested donors proved to be positive. 21 donors (30%) had high ALAT (+2 SD). Viral RNA was detected in blood of 26 donors (38%). The proportion of cases with positive viral RNA was 61% if only those donors with high ALAT levels were taken into consideration (13 positive of 21). Risk factors were found in 39 donors (57%) with antibodies to HCV. History of parenteral exposure was found to be significantly more frequent than in the control group (p = 0.0000054). Sexual transmission within couples was not demonstrated in the population tested. A positive PCR test is a probable indicator of a continuous

  17. Captopril renal scan - a noninvasive screening test for renovascular hypertension

    International Nuclear Information System (INIS)

    Akhter, M.S.

    2001-01-01

    Captopril renal scan is simple, noninvasive and cost-effective test for the initial diagnosis with the sensitivity of 98%. Renal scan with Tc-99m DTPA was performed on the suspected patient one hour after oral intake of 25 mg of captopril. Relative renal function, renogram curves and GFR for both the kidneys were calculated by computer software. Right kidney was small in size, showed relative renal function of 12% and the GFR was 9.64 ml/min. The left organ revealed relative function of 88% and the GFR was 72.12 ml/min. There was marked difference in renogram peaks. On baseline study, the right kidney showed marked improvement of renogram curve peak and the renal function improved to 23% while the GFR showed rise to 19 ml/min. In comparison with baseline findings, the right kidney, in response to ACE inhibitor showed deterioration of renogram peak, 47.8% deterioration of relative renal function and 49.2% fall in GFR. Major criteria for renovascular cause was fulfilled and the patient was labeled for having high probability for renal artery stenosis. Renal angiography, later on confirmed the diagnosis. (author)

  18. The triple test as a screening technique for Down syndrome: reliability and relevance

    Directory of Open Access Journals (Sweden)

    Tim Reynolds

    2010-05-01

    Full Text Available Tim ReynoldsClinical Chemistry Department, Queen’s Hospital, Burton-on-Trent, Staffordshire, UKAbstract: The triple test is a second trimester screening test used to identify those pregnant women who should be offered a diagnostic test to identify whether their fetus has an aneuploidy. It was first described in 1988, but has largely been superseded by newer tests either conducted earlier in the first trimester (ie, the combined test, using ultrasound measurement of nuchal translucency,pregnancy-associated plasma protein A, and human chorionic gonadotrophin [hCG] or in the second trimester (ie, the quadruple test, using α-fetoprotein, hCG, uE3, and inhibin. These newer tests have been introduced because they offer greater detection and lower screen positive results thereby enhancing diagnosis rates, while decreasing the risk of iatrogenic harm caused by the invasive testing required when collecting suitable sample tissue. Noninvasive alternatives to the triple test have been identified, but these have not been adopted despite 13 years of development. It is likely, therefore, that the triple test (or variants thereof will continue to be used in routine antenatal care for the foreseeable future.Keywords: pregnancy, screening test, antenatal, Down syndrome

  19. Do negative screening test results cause false reassurance? A systematic review.

    Science.gov (United States)

    Cooper, Grace C; Harvie, Michelle N; French, David P

    2017-11-01

    It has been suggested that receiving a negative screening test result may cause false reassurance or have a 'certificate of health effect'. False reassurance in those receiving a negative screening test result may result in them wrongly believing themselves to be at lower risk of the disease, and consequently less likely to engage in health-related behaviours that would lower their risk. The present systematic review aimed to identify the evidence regarding false reassurance effects due to negative screening test results in adults (over 18 years) screened for the presence of a disease or its precursors, where disease or precursors are linked to lifestyle behaviours. MEDLINE and PsycINFO were searched for trials that compared a group who had received negative screening results to an unscreened control group. The following outcomes were considered as markers of false reassurance: perceived risk of disease; anxiety and worry about disease; health-related behaviours or intention to change health-related behaviours (i.e., smoking, diet, physical activity, and alcohol consumption); self-rated health status. Nine unique studies were identified, reporting 55 measures in relation to the outcomes considered. Outcomes were measured at various time points from immediately following screening to up to 11 years after screening. Despite considerable variation in outcome measures used and timing of measurements, effect sizes for comparisons between participants who received negative screening test results and control participants were typically small with few statistically significant differences. There was evidence of high risk of bias, and measures of behaviours employed were often not valid. The limited evidence base provided little evidence of false reassurance following a negative screening test results on any of four outcomes examined. False reassurance should not be considered a significant harm of screening, but further research is warranted. Statement of contribution

  20. A focus group study of consumer attitudes toward genetic testing and newborn screening for deafness.

    Science.gov (United States)

    Burton, Sarah K; Withrow, Kara; Arnos, Kathleen S; Kalfoglou, Andrea L; Pandya, Arti

    2006-12-01

    Progress in identifying genes for deafness together with implementation of universal audiologic screening of newborns has provided the opportunity for more widespread use of molecular tests to detect genetic forms of hearing loss. Efforts to assess consumer attitudes toward these advances have lagged behind. Consumer focus groups were held to explore attitudes toward genetic advances and technologies for hearing loss, views about newborn hearing screening, and reactions to the idea of adding molecular screening for hearing loss at birth. Focus group discussions were recorded, transcribed and analyzed. Five focus groups with 44 participants including hearing parents of deaf children, deaf parents and young deaf adults were held. Focus group participants supported the use of genetic tests to identify the etiology of hearing loss but were concerned that genetic information might influence reproductive decisions. Molecular newborn screening was advocated by some; however, others expressed concern about its effectiveness. Documenting the attitudes of parents and other consumers toward genetic technologies establishes the framework for discussions on the appropriateness of molecular newborn screening for hearing loss and informs specialists about potential areas of public education necessary prior to the implementation of such screening.

  1. Risk factors for false positive and for false negative test results in screening with fecal occult blood testing

    NARCIS (Netherlands)

    Stegeman, Inge; de Wijkerslooth, Thomas R.; Stoop, Esther M.; van Leerdam, Monique; van Ballegooijen, M.; Kraaijenhagen, Roderik A.; Fockens, Paul; Kuipers, Ernst J.; Dekker, Evelien; Bossuyt, Patrick M.

    2013-01-01

    Differences in the risk of a false negative or a false positive fecal immunochemical test (FIT) across subgroups may affect optimal screening strategies. We evaluate whether subgroups are at increased risk of a false positive or a false negative FIT result, whether such variability in risk is

  2. Speech-in-noise screening tests by internet, part 3: test sensitivity for uncontrolled parameters in domestic usage

    NARCIS (Netherlands)

    Leensen, Monique C. J.; Dreschler, Wouter A.

    2013-01-01

    The online speech-in-noise test 'Earcheck' is sensitive for noise-induced hearing loss (NIHL). This study investigates effects of uncontrollable parameters in domestic self-screening, such as presentation level and transducer type, on speech reception thresholds (SRTs) obtained with Earcheck.

  3. Syringe test screening of microbial gas production activity: Cases denitrification and biogas formation.

    Science.gov (United States)

    Østgaard, Kjetill; Kowarz, Viktoria; Shuai, Wang; Henry, Ingrid A; Sposob, Michal; Haugen, Hildegunn Hegna; Bakke, Rune

    2017-01-01

    Mass produced plastic syringes may be applied as vessels for cheap, simple and large scale batch culture testing. As illustrated for the cases of denitrification and of biogas formation, metabolic activity was monitored by direct reading of the piston movement due to the gas volume formed. Pressure buildup due to friction was shown to be moderate. A piston pull and slide back routine can be applied before recording gas volume to minimize experimental errors due to friction. Inoculum handling and activity may be conveniently standardized as illustrated by applying biofilm carriers. A robust set of positive as well as negative controls ("blanks") should be included to ensure quality of the actual testing. The denitrification test showed saturation response at increasing amounts of inoculum in the form of adapted moving bed biofilm reactor (MBBR) carriers, with well correlated nitrate consumption vs. gas volume formed. As shown, the denitrification test efficiently screened different inocula at standardized substrates. Also, different substrates were successfully screened and compared at standardized inocula. The biogas potential test showed efficient screening of different substrates with effects of relative amounts of carbohydrate, protein, fat. A second case with CO 2 capture reclaimer waste as substrate demonstrated successful use of co-feeding to support waste treatment and how temperature effects on kinetics and stoichiometry can be observed. In total, syringe test screening of microbial gas production seems highly efficient at a low cost when properly applied. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Determinants of participation in colorectal cancer screening with faecal occult blood testing

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Brasso, Klaus; Lynge, Elsebeth

    2009-01-01

    BACKGROUND: Colorectal cancer is one of the most common cancers in men and women. Participation rates in faecal occult blood testing (FOBT) screening activities are, however, relatively low. In terms of lowering the colorectal cancer mortality, high participation rates are essential, and therefore......, but determinants varied across countries and test settings. There was no systematic variation in participation across age groups. CONCLUSION: The participation pattern depends in part on local circumstances, which makes it difficult to point to a general strategy for increasing the uptake in FOBT screening...

  5. Medical and lay attitudes towards genetic screening and testing in Finland

    DEFF Research Database (Denmark)

    Toiviainen, Hanna; Jallinoja, Piia; Aro, Arja R

    2003-01-01

    The purpose of this study was to compare physicians', midwives' and lay people's attitudes towards genetic screening and testing to find out whether medical education and experience influence attitudes of genetic screening and testing. The study was based on comparison of answers to joint questions...... in three different cross-sectional postal surveys between October 1996 and April 1998 in Finland. Target groups were physicians (study base n=772, response rate 74%, including gynaecologists, paediatricians, general practitioners and clinical geneticists), midwives and public health nurses (collectively...

  6. Imaging evaluation of infants with neuroblastoma detected by VMA screening spot test

    International Nuclear Information System (INIS)

    Fujioka, M.; Saiki, N.; Aihara, T.; Yamamoto, K.

    1988-01-01

    In the Saitama Prefecture in Japan, VMA (vanillyl manderic acid) screening spot test for detection of neuroblastoma has been performed in 173,046 infants in the years 1981-1986 and 15 infants were found to have neuroblastoma. Two infants had mediastinal tumors and the remainder, 13, had intraabdominal tumors. Only 7 infants had palpable masses. Although CT was documented to be the best imaging procedure to provide sufficient information for treatment, conventional radiographic examinations of the chest and abdomen, and abdominal ultrasonography were able, as initial imaging procedures, to detect reasonably small neuroblastomas in infants with a positive VMA screening test. (orig.)

  7. Liquid-Crystal Display (LCD) Screen Thermal Testing to Simulate Solar Gain

    Science.gov (United States)

    2015-12-01

    determined that shielding the screen from solar gains was the best way to avoid monitor failure. In order to accomplish this Hot Mirror glass from...side of the monitor in order to shield the monitor from the solar loading. 2.7 Test 7 – Bench Test with a 250 W Heat Lamp and Hot Mirror Glass , 1 Inch...method to shield the screen from solar loading. The Hot Mirror glass uses a glass substrate with a coating on 1 side that passes visible light, but

  8. Good laboratory practices for biochemical genetic testing and newborn screening for inherited metabolic disorders.

    Science.gov (United States)

    2012-04-06

    Biochemical genetic testing and newborn screening are essential laboratory services for the screening, detection, diagnosis, and monitoring of inborn errors of metabolism or inherited metabolic disorders. Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations, laboratory testing is categorized on the basis of the level of testing complexity as either waived (i.e., from routine regulatory oversight) or nonwaived testing (which includes tests of moderate and high complexity). Laboratories that perform biochemical genetic testing are required by CLIA regulations to meet the general quality systems requirements for nonwaived testing and the personnel requirements for high-complexity testing. Laboratories that perform public health newborn screening are subject to the same CLIA regulations and applicable state requirements. As the number of inherited metabolic diseases that are included in state-based newborn screening programs continues to increase, ensuring the quality of performance and delivery of testing services remains a continuous challenge not only for public health laboratories and other newborn screening facilities but also for biochemical genetic testing laboratories. To help ensure the quality of laboratory testing, CDC collaborated with the Centers for Medicare & Medicaid Services, the Food and Drug Administration, the Health Resources and Services Administration, and the National Institutes of Health to develop guidelines for laboratories to meet CLIA requirements and apply additional quality assurance measures for these areas of genetic testing. This report provides recommendations for good laboratory practices that were developed based on recommendations from the Clinical Laboratory Improvement Advisory Committee, with additional input from the Secretary's Advisory Committee on Genetics, Health, and Society; the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children; and representatives of newborn

  9. Attitudes towards colorectal cancer (CRC) and CRC screening tests among elderly Malay patients.

    Science.gov (United States)

    Al-Naggar, Redhwan A; Al-Kubaisy, Waqar; Yap, Bee W; Bobryshev, Yuri V; Osman, Muhamed T

    2015-01-01

    Colorectal cancer (CRC) is the third most common malignancy in Malaysia, where data are limited regarding knowledge and barriers in regard to CRC and screening tests. The aim of the study was to assess these parameters among Malaysians. The questionnaires were distributed in the Umra Private Hospital in Selangor. The questionnaire had four parts and covered social-demographic questions, respondent knowledge about CRC and colorectal tests, attitude towards CRC and respondentaction regarding CRC. More than half of Malay participants (total n=187) were female (57.2%) and 36.9% of them were working as professionals. The majority of the participants (93.6%) never had a CRC screening test. The study found that only 10.2% of the study participants did not consider that their chances of getting CRC were high. A high percentage of the participants (43.3%) believed that they would have good chance of survival if the cancer would be found early. About one third of the respondents did not want to do screening because of fear of cancer, and concerns of embarrassment during the procedure adversely affected attitude to CRC screening as well. Age, gender, income, family history of CRC, vegetable intake and physical activity were found to be significant determinants of knowledge on CRC. The major barriers identified towards CRC screening identified in our study were fear of pain and embarrassment. The findings have implications for understanding of similarities and differences in attitude to CRC amongst elderly patients in other cultural/ geographic regions.

  10. A single-question screening test for drug use in primary care.

    Science.gov (United States)

    Smith, Peter C; Schmidt, Susan M; Allensworth-Davies, Donald; Saitz, Richard

    2010-07-12

    Drug use (illicit drug use and nonmedical use of prescription drugs) is common but underrecognized in primary care settings. We validated a single-question screening test for drug use and drug use disorders in primary care. Adult patients recruited from primary care waiting rooms were asked the single screening question, "How many times in the past year have you used an illegal drug or used a prescription medication for nonmedical reasons?" A response of at least 1 time was considered positive for drug use. They were also asked the 10-item Drug Abuse Screening Test (DAST-10). The reference standard was the presence or absence of current (past year) drug use or a drug use disorder (abuse or dependence) as determined by a standardized diagnostic interview. Drug use was also determined by oral fluid testing for common drugs of abuse. Of 394 eligible primary care patients, 286 (73%) completed the interview. The single screening question was 100% sensitive (95% confidence interval [CI], 90.6%-100%) and 73.5% specific (95% CI, 67.7%-78.6%) for the detection of a drug use disorder. It was less sensitive for the detection of self-reported current drug use (92.9%; 95% CI, 86.1%-96.5%) and drug use detected by oral fluid testing or self-report (81.8%; 95% CI, 72.5%-88.5%). Test characteristics were similar to those of the DAST-10 and were affected very little by participant demographic characteristics. The single screening question accurately identified drug use in this sample of primary care patients, supporting the usefulness of this brief screen in primary care.

  11. Evaluation of the localization auditory screening test in children 6-18 months of age.

    Science.gov (United States)

    Tillis, C H; Grimm, W A

    1978-01-01

    The present paper is a report of a project to develop an automated auditory screening test for infants six to 18 months of age. The first year of the project was devoted to developing equipment and test procedures; the second year was concerned with testing the effectiveness of the equipment and procedures on an actual population of six to 18 month old infants. Two-hundred and fifty infants were screened auditorily as part of a county health department child development clinic. The pass/fail results of the screening test were evaluated in terms of physical and developmental examination following the screening and by means of a case review of the child's previous history. The results indicate that the procedure under investigation can be used to differentiate the normal hearing infant from the infant with possible hearing problems. It is shown by the test environment in which this study was conducted that the procedure reported can be successfully incorporated into a public health program, i.e., child development clinics or EPSDT programs.

  12. Screening Tests

    Science.gov (United States)

    ... hazardous or risky drinking. Two instruments in particular, the AUDIT and the CAGE, are cited throughout this issue— ... drinking in a very specific population—pregnant women. The AUDIT, CAGE, and T-ACE are presented here in ...

  13. Toward Joint Hypothesis-Tests Seismic Event Screening Analysis: Ms|mb and Event Depth

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Dale [Los Alamos National Laboratory; Selby, Neil [AWE Blacknest

    2012-08-14

    Well established theory can be used to combine single-phenomenology hypothesis tests into a multi-phenomenology event screening hypothesis test (Fisher's and Tippett's tests). Commonly used standard error in Ms:mb event screening hypothesis test is not fully consistent with physical basis. Improved standard error - Better agreement with physical basis, and correctly partitions error to include Model Error as a component of variance, correctly reduces station noise variance through network averaging. For 2009 DPRK test - Commonly used standard error 'rejects' H0 even with better scaling slope ({beta} = 1, Selby et al.), improved standard error 'fails to rejects' H0.

  14. Patient Preferences Regarding Colorectal Cancer Screening: Test Features and Cost Willing to Pay Out of Pocket.

    Science.gov (United States)

    Moreno, Courtney C; Weiss, Paul S; Jarrett, Thomas L; Roberts, David L; Mittal, Pardeep K; Votaw, John R

    2016-01-01

    The purpose of this investigation was to evaluate whether test features would make an individual more or less likely to undergo colorectal cancer screening and how much an individual would be willing to pay out of pocket for a screening test. The methods include an administration of a survey to consecutive adult patients of a general medicine clinic. The survey consisted of Likert-scale questions assessing the patients' likelihood of choosing a screening test based on various test characteristics. Additional questions measured the patients' age, race, gender, and maximum out-of-pocket cost they would be willing to pay. Chi-square tests were used to assess the associations between the likelihood questions and the various demographic characteristics. In results, survey response rate was 88.8% (213 of 240). Respondents were 48.4% female (103 of 213), 51.6% male (110 of 213), 82.6% White (176 of 213), 11.3% African-American (24 of 213), and 6.1% other (13 of 213). Risk of internal injury and light exposure to radiation were the least desirable test features. Light sedation was the only test feature that most respondents (54.8%) indicated would make them likely or very likely to undergo a colorectal cancer screening test. The vast majority of respondents (86.8%) were willing to pay less than $200 out of pocket for a colorectal cancer screening test. There was no statistically significant difference in the responses of males and females, or in the responses of individuals of different races or different ages regarding test features, or the amount individuals were willing to pay for a screening test. To conclude, survey results suggest that patient education emphasizing the low complication rate of computed tomographic colonography (CTC), the minimal risks associated with the low-level radiation exposure resulting from CTC, and the benefits of a sedation-free test (eg, no risk of sedation-related complication and no need for a driver) may increase patient acceptance of

  15. The Internet Process Addiction Test: Screening for Addictions to Processes Facilitated by the Internet

    Directory of Open Access Journals (Sweden)

    Jason C. Northrup

    2015-07-01

    Full Text Available The Internet Process Addiction Test (IPAT was created to screen for potential addictive behaviors that could be facilitated by the internet. The IPAT was created with the mindset that the term “Internet addiction” is structurally problematic, as the Internet is simply the medium that one uses to access various addictive processes. The role of the internet in facilitating addictions, however, cannot be minimized. A new screening tool that effectively directed researchers and clinicians to the specific processes facilitated by the internet would therefore be useful. This study shows that the Internet Process Addiction Test (IPAT demonstrates good validity and reliability. Four addictive processes were effectively screened for with the IPAT: Online video game playing, online social networking, online sexual activity, and web surfing. Implications for further research and limitations of the study are discussed.

  16. The Internet Process Addiction Test: Screening for Addictions to Processes Facilitated by the Internet.

    Science.gov (United States)

    Northrup, Jason C; Lapierre, Coady; Kirk, Jeffrey; Rae, Cosette

    2015-07-28

    The Internet Process Addiction Test (IPAT) was created to screen for potential addictive behaviors that could be facilitated by the internet. The IPAT was created with the mindset that the term "Internet addiction" is structurally problematic, as the Internet is simply the medium that one uses to access various addictive processes. The role of the internet in facilitating addictions, however, cannot be minimized. A new screening tool that effectively directed researchers and clinicians to the specific processes facilitated by the internet would therefore be useful. This study shows that the Internet Process Addiction Test (IPAT) demonstrates good validity and reliability. Four addictive processes were effectively screened for with the IPAT: Online video game playing, online social networking, online sexual activity, and web surfing. Implications for further research and limitations of the study are discussed.

  17. Seroprevalence, molecular epidemiology and quantitation of parvovirus B19 DNA levels in Iranian blood donors.

    Science.gov (United States)

    Zadsar, Maryam; Aghakhani, Arezoo; Banifazl, Mohammad; Kazemimanesh, Monireh; Tabatabaei Yazdi, Seyed Morteza; Mamishi, Setareh; Bavand, Anahita; Sadat Larijani, Mona; Ramezani, Amitis

    2018-04-16

    Human parvovirus B19 (B19) infection is common among blood donors, and healthy blood donors can transmit virus via transfusion. Due to resistance of B19 to viral inactivation methods, there is a potential concern regarding transfusion safety in blood products. We aimed to determine the seroprevalence, molecular epidemiology, and quantitation of B19 DNA levels in blood donors in Tehran, Iran. A total of 500 blood donors from Blood Transfusion Research Center were studied. ELISA was used for detection of B19 IgG and IgM and nested PCR was carried out for detection of B19 DNA. PCR products were subjected to direct sequencing. B19 viral load was determined by real time PCR. B19 IgG, IgM, and DNA were detected in 27.6, 2.6, and 1.2% of donors respectively. Ten samples (2%) were positive for both antibodies while in four cases (0.8%), B19 IgG and DNA detected simultaneously. One case had B19 IgM, IgG, and viremia concurrently. The titers of B19 DNA in four of six donors were more than 10 6  IU/mL (high level viremia) and all four cases had IgG simultaneously. All B19 isolates categorized in genotype 1A. Our findings indicated that prevalence of B19 DNA in Iranian blood donors was comparable with previous studies throughout the world. High level B19 viremia found in 0.8% of our donors and all viremic donors revealed neutralizing B19 antibody. Therefore implementation of a B19 screening test for each volunteer blood donor does not appear to be necessary but B19 testing for plasma-derived products seems important in Iranian donors. © 2018 Wiley Periodicals, Inc.

  18. Algorithm for recall of HIV reactive Indian blood donors by sequential immunoassays enables selective donor referral for counseling

    Directory of Open Access Journals (Sweden)

    Thakral B

    2006-01-01

    Full Text Available Background: HIV/AIDS pandemic brought into focus the importance of safe blood donor pool. Aims: To analyze true seroprevalence of HIV infection in our blood donors and devise an algorithm for donor recall avoiding unnecessary referrals to voluntary counseling and testing centre (VCTC. Materials and Methods: 39,784 blood units were screened for anti-HIV 1/2 using ELISA immunoassay (IA-1. Samples which were repeat reactive on IA-1 were further tested using two different immunoassays (IA-2 and IA-3 and Western blot (WB. Based on results of these sequential IAs and WB, an algorithm for recall of true HIV seroreactive blood donors is suggested for countries like India where nucleic acid testing or p24 antigen assays are not mandatory and given the limited resources may not be feasible. Results: The anti-HIV seroreactivity by repeat IA-1, IA-2, IA-3 and WB were 0.16%, 0.11%, 0.098% and 0.07% respectively. Of the 44 IA-1 reactive samples, 95.2% (20/21 of the seroreactive samples by both IA-2 and IA-3 were also WB positive and 100% (6/6 of the non-reactive samples by these IAs were WB negative. IA signal/cutoff ratio was significantly low in biological false reactive donors. WB indeterminate results were largely due to non-specific reactivity to gag protein (p55. Conclusions: HIV seroreactivity by sequential immunoassays (IA-1, IA-2 and IA-3; comparable to WHO Strategy-III prior to donor recall results in decreased referral to VCTC as compared to single IA (WHO Strategy-I being followed currently in India. Moreover, this strategy will repose donor confidence in our blood transfusion services and strengthen voluntary blood donation program.

  19. SUMA Technology and Newborn Screening Tests for Inherited Metabolic Diseases in Cuba

    Directory of Open Access Journals (Sweden)

    Ernesto Carlos González Reyes PhD

    2016-07-01

    Full Text Available The ultramicroanalytic system (SUMA, created in the 1980s, is a complete system of reagents and instrumentation to perform ultramicroassays combining the sensitivity of the micro-enzyme-linked immunosorbent assay (ELISA tests with the use of ultramicrovolumes. This technology permitted establishing large-scale newborn screening programs (NSPs for metabolic and endocrine disorders in Cuba. This article summarizes the main results of the implementation during the 30 years of SUMA technology in NSP for 5 inherited metabolic diseases, using ultramicroassays developed at the Department of Newborn Screening at the Immunoassay Center. Since 1986, SUMA technology has been used in the Cuban NSP for congenital hypothyroidism, initially studying thyroid hormone in cord serum samples. In 2000, a decentralized program for the detection of hyperphenylalaninemias using heel dried blood samples was initiated. These successful experiences permitted including protocols for screening congenital adrenal hyperplasia, galactosemia, and biotinidase deficiency in 2005. A program for the newborn screening of CH using the thyroid-stimulating hormone Neonatal ultramicro-ELISA was fully implemented in 2010. Nowadays, the NSP is supported by a network of 175 SUMA laboratories. After 30 years, more than 3.8 million Cuban newborns have been screened, and 1002 affected children have been detected. Moreover, SUMA technology has been presented in Latin America for over 2 decades and has contributed to screen around 17 million newborns. These results prove that developing countries can develop appropriate diagnostic technologies for making health care accessible to all.

  20. Validity of Commonly Used Clinical Tests to Diagnose and Screen for Spinal Pain in Adolescents

    DEFF Research Database (Denmark)

    Aartun, Ellen; Hartvigsen, Jan; Hestbaek, Lise

    2016-01-01

    , the area under the receiver operating characteristic curve ranged from 0.60 to 0.65. None of the selected tests could predict incidence cases of neck pain, mid back pain, or low back pain. CONCLUSION: Clinical tests commonly used in spinal screening in adolescents could not detect present spinal pain...... under the receiver operating characteristic curve was calculated for evaluation of all tests combined. RESULTS: The sensitivity was low, and specificity was high for all tests at both baseline (age, 11-13 years) and follow-up (age, 13-15 years). When all tests were evaluated collectively in 1 model...

  1. Self-Sampling for Human Papillomavirus Testing among Non-Attenders Increases Attendance to the Norwegian Cervical Cancer Screening Programme

    DEFF Research Database (Denmark)

    Enerly, Espen; Bonde, Jesper; Schee, Kristina

    2016-01-01

    Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance....... To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25-69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited...... alternative for increasing cervical cancer screening coverage in Norway....

  2. Screening test recommendations for methicillin-resistant Staphylococcus aureus surveillance practices: A cost-minimization analysis.

    Science.gov (United States)

    Whittington, Melanie D; Curtis, Donna J; Atherly, Adam J; Bradley, Cathy J; Lindrooth, Richard C; Campbell, Jonathan D

    2017-07-01

    To mitigate methicillin-resistant Staphylococcus aureus (MRSA) infections, intensive care units (ICUs) conduct surveillance through screening patients upon admission followed by adhering to isolation precautions. Two surveillance approaches commonly implemented are universal preemptive isolation and targeted isolation of only MRSA-positive patients. Decision analysis was used to calculate the total cost of universal preemptive isolation and targeted isolation. The screening test used as part of the surveillance practice was varied to identify which screening test minimized inappropriate and total costs. A probabilistic sensitivity analysis was conducted to evaluate the range of total costs resulting from variation in inputs. The total cost of the universal preemptive isolation surveillance practice was minimized when a polymerase chain reaction screening test was used ($82.51 per patient). Costs were $207.60 more per patient when a conventional culture was used due to the longer turnaround time and thus higher isolation costs. The total cost of the targeted isolation surveillance practice was minimized when chromogenic agar 24-hour testing was used ($8.54 per patient). Costs were $22.41 more per patient when polymerase chain reaction was used. For ICUs that preemptively isolate all patients, the use of a polymerase chain reaction screening test is recommended because it can minimize total costs by reducing inappropriate isolation costs. For ICUs that only isolate MRSA-positive patients, the use of chromogenic agar 24-hour testing is recommended to minimize total costs. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  3. Can the Bruckner test be used as a rapid screening test to detect significant refractive errors in children?

    Directory of Open Access Journals (Sweden)

    Kothari Mihir

    2007-01-01

    Full Text Available Purpose: To assess the suitability of Brückner test as a screening test to detect significant refractive errors in children. Materials and Methods: A pediatric ophthalmologist prospectively observed the size and location of pupillary crescent on Brückner test as hyperopic, myopic or astigmatic. This was compared with the cycloplegic refraction. Detailed ophthalmic examination was done for all. Sensitivity, specificity, positive predictive value and negative predictive value of Brückner test were determined for the defined cutoff levels of ametropia. Results: Ninety-six subjects were examined. Mean age was 8.6 years (range 1 to 16 years. Brückner test could be completed for all; the time taken to complete this test was 10 seconds per subject. The ophthalmologist identified 131 eyes as ametropic, 61 as emmetropic. The Brückner test had sensitivity 91%, specificity 72.8%, positive predictive value 85.5% and negative predictive value 83.6%. Of 10 false negatives four had compound hypermetropic astigmatism and three had myopia. Conclusions: Brückner test can be used to rapidly screen the children for significant refractive errors. The potential benefits from such use may be maximized if programs use the test with lower crescent measurement cutoffs, a crescent measurement ruler and a distance fixation target.

  4. Influence of test reliability on the screening performance of frequency-doubling perimetry

    NARCIS (Netherlands)

    Heeg, GP; Jansonius, NM

    PURPOSE: To investigate the influence of test reliability on the screening performance of frequency,doubling perimetry (FDT). DESIGN: Cross-sectional study. METHODS: FDT sensitivity and specificity were calculated three times using three different strategies for handling unreliable (that is, > 0

  5. Individual differences in aversion to ambiguity regarding medical tests and treatments: association with cancer screening cognitions.

    Science.gov (United States)

    Han, Paul K J; Williams, Andrew E; Haskins, Amy; Gutheil, Caitlin; Lucas, F Lee; Klein, William M P; Mazor, Kathleen M

    2014-12-01

    Aversion to "ambiguity"-uncertainty about the reliability, credibility, or adequacy of information-about medical tests and treatments is an important psychological response that varies among individuals, but little is known about its nature and extent. The purpose of this study was to examine how individual-level ambiguity aversion relates to important health cognitions related to different cancer screening tests. A survey of 1,074 adults, ages 40 to 70 years, was conducted in four integrated U.S. healthcare systems. The Ambiguity Aversion in Medicine (AA-Med) scale, a measure of individual differences in aversion to ambiguity (AA) about medical tests and treatments, was administered along with measures of several cancer screening-related cognitions: perceived benefits and harms of colonoscopy, mammography, and PSA screening, and ambivalence and future intentions regarding these tests. Multivariable analyses were conducted to assess the associations between AA-Med scores and cancer screening cognitions. Individual-level AA as assessed by the AA-Med scale was significantly associated (P ambiguity. Individual-level AA constitutes a measurable, wide-ranging cognitive bias against medical intervention, and more research is needed to elucidate its mechanisms and effects. ©2014 American Association for Cancer Research.

  6. Participation behaviour following a false positive test in the Copenhagen mammography screening programme

    DEFF Research Database (Denmark)

    Andersen, Sune Bangsbøll; Vejborg, Ilse; von Euler-Chelpin, My

    2008-01-01

    women experiencing a negative screening test, regardless of whether the false positive statement was given following assessment or following surgery. The benign to malignant biopsy ratio, comparing the type B false positives to the true positives, was by the fifth round well below the desirable level...

  7. Noninvasiv prænatal test er et gennembrud inden for prænatal screening

    DEFF Research Database (Denmark)

    Hornstrup, Louise Stig; Ambye, Louise; Sørensen, Steen

    2015-01-01

    Non-invasive prenatal testing (NIPT) using cell-free fetal DNA from the peripheral blood of the pregnant woman has become a possibility within recent years, but is not yet implemented in Denmark. NIPT has proven to be very efficient in the screening for especially trisomi 21. This article...

  8. Screening of Plant Extracts for Antioxidant Activity: a Comparative Study on Three Testing Methods

    NARCIS (Netherlands)

    Koleva, I.; Beek, van T.A.; Linssen, J.P.H.; Groot, de Æ.; Evstatieva, L.N.

    2002-01-01

    Three methods widely employed in the evaluation of antioxidant activity, namely 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging method, static headspace gas chromatography (HS-GC) and -carotene bleaching test (BCBT), have been compared with regard to their application in the screening of

  9. Concordant testing results between various Human Papillomavirus assays in primary cervical cancer screening

    DEFF Research Database (Denmark)

    de Thurah, Lena; Bonde, Jesper; Hoa Lam, Janni Uyen

    2018-01-01

    OBJECTIVES: Human Papillomavirus (HPV) assays are increasingly used for primary cervical screening and HPV vaccination effect monitoring. We undertook a systematic literature review to determine the concordance in positive test results (i.e., detection of HPV infections) between Hybrid Capture 2 ...

  10. Contribution to the study for an optimum choice of filter and screens in radiographic testing

    International Nuclear Information System (INIS)

    Caillieret, V.; Peix, G.; Babot, D.; Lormand, G.

    1985-01-01

    In order to optimize the choices of screens and filter in steel specimens radiographic testing with iridium 192 and cobalt 60, we started a theoretical and experimental study of their actions on radiative and latent images formation. Theoretical modelisation of photons interactions in steel and experimental apparatus for spectral analysis are described

  11. Screening for congenital toxoplasmosis: accuracy of immunoglobulin M and immunoglobulin A tests after birth

    DEFF Research Database (Denmark)

    Gilbert, Ruth E; Thalib, Lukman; Tan, Hooi Kuan

    2007-01-01

    OBJECTIVES: To determine the accuracy of postnatal screening for toxoplasma-specific immunoglobulin (Ig) M and IgA. SETTING: Ten centres in three European countries. METHODS: We compared results of the first postnatal IgM or IgA test in infants with infected mothers identified by prenatal screeni...

  12. Spectrum of patients with hypermethioninemia based on neonatal screening tests over 14 years

    Directory of Open Access Journals (Sweden)

    Se Jung Oh

    2010-03-01

    Full Text Available Purpose : The neonatal screening test for homocystinuria primarily measures methionine by using a dried blood specimen. We investigated the incidence and clinical manifestations of homocystinuria, isolated hypermethioninemia, and transient hypermethioninemia among patients with hypermethioninemia on a neonatal screening test. Methods : We performed a retrospective study of 58 patients transferred to Shoonchunhyang Hospital because of hypermethioninemia on a neonatal screening test between January 1996 and August 2009. We analyzed the level of amino acid from plasma and urine, as well as blood homocysteine. Results : Almost half of the 58 patients were identified as normal. Whereas only 3 (5.1% patients were identified as having homocystinuria, about 20.7% (12 cases of the patients had isolated hypermethioninemia. The ages of these two groups at initial detection of hypermethioninemia on plasma amino acid analysis were 50.0¡?#?2.5; days and 34.9¡?#?3.5; days, respectively. Both groups were put on diets, and they showed a normal developmental course as a result of early diagnosis and treatment. Conclusion : Hypermethioninemia without homocystinuria, referred to as isolated hypermethioninemia, was also detected. Thus, the impact of hypermethioninemia on a neonatal screening test should be carefully evaluated through analysis of amino acid levels from blood and urine, and we need to detect and treat an early stage of isolated hypermethioninemia as well as homocystinuria.

  13. Evaluation of a Screening Test for Female College Athletes with Eating Disorders and Disordered Eating

    Science.gov (United States)

    Nagel, Deborah L.; Black, David R.; Leverenz, Larry J.; Coster, Daniel C.

    2000-01-01

    Objective: To develop a screening test to detect female college athletes with eating disorders/disordered eating (ED/ DE). No validated eating disorder screening tests specifically for athletes have been available. Design and Setting: In this cross-sectional study, subjects from a large midwestern university completed 3 objective tests and a structured diagnostic interview. Measurements: A new test, developed and pilot tested by the researchers (Athletic Milieu Direct Questionnaire, AMDQ), and 2 tests normed for the general population (Eating Disorder Inventory-2, Bulimia Test-Revised) were used to identify ED/DE athletes. A structured, validated, diagnostic interview (Eating Disorder Examination, version 12.OD) was used to determine which test was most effective in screening female college athletes. Subjects: Subjects included 149 female athletes, ages 18 to 25 years, from 11 Division I and select club sports. Results: ED/DE subjects (35%) were found in almost every sport. Of the ED/DE subjects, 65% exhibited disordered eating, 25% were bulimic, 8% were classified as eating disordered not otherwise specified (NOS), and 2% were anorexic. The AMDQ more accurately identified ED/DE than any test or combination of items. The AMDQ produced superior results on 7 of 9 epidemiologic analyses; sensitivity was 80% and specificity was 77%, meaning that it correctly classified approximately 4 of every 5 persons who were truly exhibiting an eating disorder or disordered eating. Conclusions: We recommend that the AMDQ subsets, which met statistical criteria, be used to screen for ED/DE to enable early identification of athletes at the disordered eating or NOS stage and to initiate interventions before the disorder progresses. PMID:16558658

  14. Interpretation of Errors Made by Mandarin-Speaking Children on the Preschool Language Scales--5th Edition Screening Test

    Science.gov (United States)

    Ren, Yonggang; Rattanasone, Nan Xu; Wyver, Shirley; Hinton, Amber; Demuth, Katherine

    2016-01-01

    We investigated typical errors made by Mandarin-speaking children when measured by the Preschool Language Scales-fifth edition, Screening Test (PLS-5 Screening Test). The intention was to provide preliminary data for the development of a guideline for early childhood educators and psychologists who use the test with Mandarin-speaking children.…

  15. Testing for direct genetic effects using a screening step in family-based association studies

    Directory of Open Access Journals (Sweden)

    Sharon M Lutz

    2013-11-01

    Full Text Available In genome wide association studies (GWAS, families based studies tend to have less power to detect genetic associations than population based studies, such as case-control studies. This can be an issue when testing if genes in a family based GWAS have a direct effect on the phenotype of interest or if the genes act indirectly through a secondary phenotype. When multiple SNPs are tested for a direct effect in the family based study, a screening step can be used to minimize the burden of multiple comparisons in the causal analysis. We propose a 2-stage screening step that can be incorporated into the family based association test (FBAT approach similar to the conditional mean model approach in the VanSteen-algorithm [1]. Simulations demonstrate that the type 1 error is preserved and this method is advantageous when multiple markers are tested. This method is illustrated by an application to the Framingham Heart Study.

  16. Evaluation of Calypte AWARE HIV-1/2 OMT antibody test as a screening test in an Indian setting

    Directory of Open Access Journals (Sweden)

    Ingole N

    2010-01-01

    Full Text Available Purpose: Integrated counselling and testing centres (ICTC provide counselling and blood testing facilities for HIV diagnosis. Oral fluid tests provide an alternative for people whodo not want blood to be drawn. Also, it avoids the risk of occupational exposure. The goal of this study was to evaluate the utility of Calypte AWARE HIV-1/2 OMT antibody test as a screening test in an Indian setting. Materials and Methods: A cross-sectional study was carried out after ethics committee approval in 250 adult ICTC clients. Blood was collected and tested from these clients for HIV diagnosis as per routine policy and the results were considered as the gold standard. Also, after another written informed consent, oral fluid was collected from the clients and tested for the presence of HIV antibodies. Twenty five clients who had and 25 clients who had not completed their secondary school education (Group A and Group B, respectively were also asked to perform and interpret the test on their own and their findings and experiences were noted. Result: The sensitivity, specificity, PPV and NPV of the oral fluid antibody test were 100%, 98.51%, 94.11% and 100%, respectively. Seventy six percent of clients preferred oral fluid testing. Group B found it difficult to perform the test as compared to Group A and this difference was statistically significant (P ≤ 0.05. Conclusion: Oral fluid testing can be used as a screening test for HIV diagnosis; however, confirmation of reactive results by blood-based tests is a must.

  17. Awareness and uptake of colorectal, breast, cervical and prostate cancer screening tests in Spain.

    Science.gov (United States)

    Carrasco-Garrido, Pilar; Hernandez-Barrera, Valentın; Lopez de Andres, Ana; Jimenez-Trujillo, Isabel; Gallardo Pino, Carmen; Jimenez-Garcıa, Rodrigo

    2014-04-01

    We aim to describe levels of awareness and uptake of colorectal, breast, cervical and prostate cancer screening tests and to analyze the association to socio-demographic and health-related variables. Population-based cross-sectional study conducted using a home-based personal interview survey on a nationwide representative sample (n = 7938) of population aged ≥18 years (Oncobarometro Survey). Awareness was assessed by asking participants: Now I am going to mention several medical tests for cancer detection, please tell me if you already know about them or if this is the first time you have heard of them? The tests mentioned were faecal occult blood test (FOBT), mammography, Pap smear and prostate-specific antigen (PSA). Cancer screening uptake was assessed by asking participants whether they had received tests within the previous 2 years. Awareness rates of 38.55% for FOBT, 95.03% for mammography, 70.84% for Pap smears and 54.72% for PSA were found. Uptake mammography was 74.46%, Pap smears 65.57%, PSA 35.19% and FOBT 9.40%. Factors such as immigration status, lower educational level or income and not suffering from chronic conditions are negative predictors for uptake. Awareness and uptake results showed acceptable figures for mammography, moderate for Pap smears and unacceptably low for FOBT. Inequalities exist in uptake of cancer screening. It is necessary to develop public health educational programmes, especially for the vulnerable populations, aiming to inform and motivate them to use screening services on a regular basis. Our data suggest that although PSA is not recommended, this opportunistic screening is frequently used in Spain.

  18. Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis

    OpenAIRE

    An, Jingna; Chen, Qixia; Liu, Qianqian; Rao, Chenli; Li, Dongdong; Wang, Tingting; Tao, Chuanmin; Wang, Lanlan

    2015-01-01

    The resurgence of syphilis in recent years has become a serious threat to public health worldwide, and the serological detection of specific antibodies against Treponema pallidum remains the most reliable method for laboratory diagnosis of syphilis. This study examined the performance of the recently launched HISCL anti-Treponema pallidum (anti-TP) assay as a screening test for syphilis in a high-volume laboratory. The HISCL anti-TP assay was tested in 300 preselected syphilis-positive sample...

  19. Blood donor recruitment strategies and their impact on blood safety in Egypt.

    Science.gov (United States)

    Hussein, Eiman

    2014-02-01

    Because of the high incidence of HCV, blood safety presents a serious challenge in Egypt. Given the constrained economy which limits the implementation of nucleic acid amplification technology, proper recruitment of blood donors becomes of paramount importance. To evaluate the effectiveness of blood donor recruitment strategies, the seroprevalence of positive infectious markers among blood donors was studied. Donors' records covering the period from 2006-2012 were reviewed. Blood donations were screened for HCV antibodies, HBs antigen (HBsAg), HIV-1 and 2 and syphilis antibodies. Of 308,762 donors, 63.4% were voluntary donors (VD). VD of 2011-2012 were significantly younger than family replacement donors (RD) .The overall prevalences of HCV antibodies, HBsAg, HIV and syphilis antibodies were 4.3%, 1.22%, 0.07%, and 0.13%, respectively. All tested markers (except HIV) were significantly higher among RD, when compared to VD (P<0.0001). A consistent steady trend for decrease in HCV seropositivity was observed in RD and VD from 8.9% and 4.2% to 3.8% and 1.5%, respectively. A trend for decrease in HBsAg was demonstrated in VD from 1.2% to 0.53%. The decreasing trends in HCV antibody and HBs antigen is promising and may reflect the improved donor selection criteria. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Application of direct agglutination test (DAT) and fast agglutination screening test (FAST) for sero-diagnosis of visceral leishmaniasis in endemic area of Minas Gerais, Brazil

    NARCIS (Netherlands)

    Silva, Eduardo S.; Schoone, Gerard J.; Gontijo, Celia M. F.; Brazil, Reginaldo P.; Pacheco, Raquel S.; Schallig, Henk D. F. H.

    2005-01-01

    The direct agglutination test (DAT) has proved to be a very important sero-diagnostic tool combining high levels of intrinsic validity and ease of performance. Otherwise, fast agglutination screening test (FAST) utilises only one serum dilution making the test very suitable for the screening of

  1. Correlation Between Screening Mammography Interpretive Performance on a Test Set and Performance in Clinical Practice.

    Science.gov (United States)

    Miglioretti, Diana L; Ichikawa, Laura; Smith, Robert A; Buist, Diana S M; Carney, Patricia A; Geller, Berta; Monsees, Barbara; Onega, Tracy; Rosenberg, Robert; Sickles, Edward A; Yankaskas, Bonnie C; Kerlikowske, Karla

    2017-10-01

    Evidence is inconsistent about whether radiologists' interpretive performance on a screening mammography test set reflects their performance in clinical practice. This study aimed to estimate the correlation between test set and clinical performance and determine if the correlation is influenced by cancer prevalence or lesion difficulty in the test set. This institutional review board-approved study randomized 83 radiologists from six Breast Cancer Surveillance Consortium registries to assess one of four test sets of 109 screening mammograms each; 48 radiologists completed a fifth test set of 110 mammograms 2 years later. Test sets differed in number of cancer cases and difficulty of lesion detection. Test set sensitivity and specificity were estimated using woman-level and breast-level recall with cancer status and expert opinion as gold standards. Clinical performance was estimated using women-level recall with cancer status as the gold standard. Spearman rank correlations between test set and clinical performance with 95% confidence intervals (CI) were estimated. For test sets with fewer cancers (N = 15) that were more difficult to detect, correlations were weak to moderate for sensitivity (woman level = 0.46, 95% CI = 0.16, 0.69; breast level = 0.35, 95% CI = 0.03, 0.61) and weak for specificity (0.24, 95% CI = 0.01, 0.45) relative to expert recall. Correlations for test sets with more cancers (N = 30) were close to 0 and not statistically significant. Correlations between screening performance on a test set and performance in clinical practice are not strong. Test set performance more accurately reflects performance in clinical practice if cancer prevalence is low and lesions are challenging to detect. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  2. The use of the osmole gap as a screening test for the presence of exogenous substances.

    Science.gov (United States)

    Purssell, Roy A; Lynd, Larry D; Koga, Yoshikata

    2004-01-01

    The rapid and accurate diagnosis of toxic alcohol poisoning due to methanol (methyl alcohol) [MeOH] and ethylene glycol (EG), is paramount in preventing serious adverse outcomes. The quantitative measurement of specific serum levels of these substances using gas chromatography is expensive, time consuming and generally only available at major tertiary-care facilities. Therefore, because these toxic substances are osmotically active and the measurement of serum osmolality is easily performed and more readily available, the presence of an osmole gap (OG) has been adopted as an alternative screening test. By definition, the OG is the difference between the measured serum osmolality determined using the freezing point depression (Osm(m)) and the calculated serum molarity (Mc), which is estimated from the known and readily measurable osmotically active substances in the serum, in particular sodium, urea, glucose, and potassium and ethanol (alcohol). Thus, the OG=Osm(m)-Mc, and an OG above a specific threshold (the threshold of positivity) suggests the presence of unmeasured osmotically active substances, which could be indicative of a toxic exposure. The objectives of this study were to review the principles of evaluating screening tests, the theory behind the OG as a screening test and the literature upon which the adoption of the OG as a screening test has been based. This review revealed that there have been numerous equations derived and proposed for the estimation of the Mc, with the objective of developing empirical evidence of the best equation for the determination of the OG and ultimately the utility of OG as a screening test. However, the methods and statistical analysis employed have generally been inconsistent with recommended guidelines for screening test evaluation and although many equations have been derived, they have not been appropriately validated. Specific evidence of the clinical utility of the OG requires that a threshold of positivity be

  3. Uptake of a colorectal cancer screening blood test in people with elevated risk for cancer who cannot or will not complete a faecal occult blood test.

    Science.gov (United States)

    Symonds, Erin L; Cock, Charles; Meng, Rosie; Cole, Stephen R; Fraser, Robert J L; Young, Graeme P

    2017-03-31

    Participation rates in colorectal cancer (CRC) screening programmes using faecal occult blood tests (FOBTs) are low. Nonparticipation is commonly attributed to psychosocial factors, but some medical conditions also prevent screening. These barriers might be partially overcome if a blood test for CRC screening was available. This study determined whether people who had always declined screening by FOBT would participate if offered a blood test. An audit of registrants within a personalized CRC screening programme was undertaken to determine the reasons for regular nonparticipation in FOBT. Consistent nonparticipants (n=240) were randomly selected and invited for CRC screening with a blood test. Demographic characteristics and the reasons for prior FOBT nonparticipation were collected by means of a questionnaire. Nonparticipation in the screening programme could be classified as either behavioural (8.6%), with consistent noncompliance, or due to medical contraindications (8.5%), which included chronic rectal bleeding, being deemed unsuitable by a health professional, and needing personal assistance. Blood test uptake was 25%, with participation in the medical contraindications group greater than that in the behavioural group (43 vs. 12%, Pprocrastination and dislike of the test, but these were not associated with blood test uptake (P>0.05). There is a subgroup of the community who have medical reasons for nonparticipation in CRC screening with FOBT but will participate if offered a blood test. The option of a blood test does not, however, improve uptake in those who admit to behavioural reasons for noncompliance with screening.

  4. RBC Antibody Screen

    Science.gov (United States)

    ... C Cystic Fibrosis (CF) Gene Mutations Testing Cytomegalovirus (CMV) Tests D-dimer Dengue Fever Testing Des-gamma- ... Index of Screening Recommendations Not Listed? Not Listed? Newborn Screening Screening Tests for Infants Screening Tests for ...

  5. Prevalence and intensity of malaria in blood donors at Nnamdi ...

    African Journals Online (AJOL)

    Prevalence and intensity of malaria in blood donors at Nnamdi Azikiwe University Teaching Hospital (NAUTH) Nnewi, Anambra State, Nigeria. ... Apprentices and primary school dropouts constituted the most frequent donors. These differences were between the two donor-groups statistically significant (p<0.05). Screening ...

  6. A score based on screening tests to differentiate mild cognitive impairment from subjective memory complaints

    Directory of Open Access Journals (Sweden)

    Fábio Henrique de Gobbi Porto

    2013-09-01

    Full Text Available It is not easy to differentiate patients with mild cognitive impairment (MCI from subjective memory complainers (SMC. Assessments with screening cognitive tools are essential, particularly in primary care where most patients are seen. The objective of this study was to evaluate the diagnostic accuracy of screening cognitive tests and to propose a score derived from screening tests. Elderly subjects with memory complaints were evaluated using the Mini Mental State Examination (MMSE and the Brief Cognitive Battery (BCB. We added two delayed recalls in the MMSE (a delayed recall and a late-delayed recall, LDR, and also a phonemic fluency test of letter P fluency (LPF. A score was created based on these tests. The diagnoses were made on the basis of clinical consensus and neuropsychological testing. Receiver operating characteristic curve analyses were used to determine area under the curve (AUC, the sensitivity and specificity for each test separately and for the final proposed score. MMSE, LDR, LPF and delayed recall of BCB scores reach statistically significant differences between groups (P=0.000, 0.03, 0.001 and 0.01, respectively. Sensitivity, specificity and AUC were MMSE: 64%, 79% and 0.75 (cut off <29; LDR: 56%, 62% and 0.62 (cut off <3; LPF: 71%, 71% and 0.71 (cut off <14; delayed recall of BCB: 56%, 82% and 0.68 (cut off <9. The proposed score reached a sensitivity of 88% and 76% and specificity of 62% and 75% for cut off over 1 and over 2, respectively. AUC were 0.81. In conclusion, a score created from screening tests is capable of discriminating MCI from SMC with moderate to good accurancy.

  7. The Clock Drawing Test versus Mini-mental Status Examination as a Screening Tool for Dementia: A Clinical Comparison

    Science.gov (United States)

    Palsetia, Delnaz; Rao, G. Prasad; Tiwari, Sarvada C.; Lodha, Pragya; De Sousa, Avinash

    2018-01-01

    There is a growing incidence of dementia patients in the community, and with this growth, there is need for rapid, valid, and easily administrable tests for the screening of dementia and mild cognitive impairment in the community. This review looks at the two most commonly used tests in dementia screening, namely, the clock drawing test (CDT) and the mini-mental status examination (MMSE). Both these tests have been used in dementia screening over the past three decades and have been the subject of scrutiny of various studies, reviews, and meta-analysis. Both these tests are analyzed on their ability to assess dementia and screen for it in the community, general practice and general hospital settings. The methods of administration and scoring of each test are discussed, and their advantages and disadvantages are explained. There is also a direct comparison made between the MMSE and CDT in dementia screening. Future research needs with these tests are also elucidated. PMID:29403122

  8. The Clock Drawing Test versus Mini-mental Status Examination as a Screening Tool for Dementia: A Clinical Comparison.

    Science.gov (United States)

    Palsetia, Delnaz; Rao, G Prasad; Tiwari, Sarvada C; Lodha, Pragya; De Sousa, Avinash

    2018-01-01

    There is a growing incidence of dementia patients in the community, and with this growth, there is need for rapid, valid, and easily administrable tests for the screening of dementia and mild cognitive impairment in the community. This review looks at the two most commonly used tests in dementia screening, namely, the clock drawing test (CDT) and the mini-mental status examination (MMSE). Both these tests have been used in dementia screening over the past three decades and have been the subject of scrutiny of various studies, reviews, and meta-analysis. Both these tests are analyzed on their ability to assess dementia and screen for it in the community, general practice and general hospital settings. The methods of administration and scoring of each test are discussed, and their advantages and disadvantages are explained. There is also a direct comparison made between the MMSE and CDT in dementia screening. Future research needs with these tests are also elucidated.

  9. Method for screening the Nevada Test Site and contiguous areas for nuclear waste repository locations

    International Nuclear Information System (INIS)

    Sinnock, S.; Fernandez, J.A.; Neal, J.T.; Stephens, H.P.; Hartway, B.L.; Los Alamos Technical Associates, Inc., NM)

    1982-01-01

    This paper outlines the general concepts of a technical method for systematic screening of the Nevada Test Site (NTS), Nye County, Nevada, for potentially suitable nuclear waste repository locations. After a general discussion of the organization and the purpose of the current screening activity, the paper addresses the steps of the screening method. These steps include: hierarchically organizing technical objectives for repository performance (an objectives tree); identifying and mapping pertinent physical characteristics of a site and its setting (physical attributes); relating the physical conditions to the objectives (favorability curves); identifying alternative locations and numerically evaluating their relative merits; investigating the effects of subjective judgments on the evaluations (sensitivity analyses); documenting the assumptions, logic, and results of the method. 19 references, 10 figures

  10. Thalassemia and Hemoglobin E in Southern Thai Blood Donors

    Directory of Open Access Journals (Sweden)

    Manit Nuinoon

    2014-01-01

    Full Text Available Thalassemia and hemoglobin E (Hb E are common in Thailand. Individuals with thalassemia trait usually have a normal hemoglobin concentration or mild anemia. Therefore, thalassemic individuals who have minimum acceptable Hb level may be accepted as blood donors. This study was aimed at determining the frequency of α-thalassemia 1 trait, β-thalassemia trait, and Hb E-related syndromes in Southern Thai blood donors. One hundred and sixteen voluntary blood donors, Southern Thailand origin, were recruited for thalassemia and Hb E screening by red blood cell indices/dichlorophenolindophenol precipitation test. β-Thalassemia and Hb E were then identified by high performance liquid chromatography and 4 common α-thalassemia deletions were characterized by a single tube-multiplex gap-polymerase chain reaction. Overall frequency of hemoglobinopathies was 12.9%, classified as follows: homozygous α-thalassemia 2 (1.7%, heterozygous α-thalassemia 1 (1.7%, heterozygous β-thalassemia without α-thalassemia (0.9%, heterozygous Hb E without α-thalassemia (5.2%, double heterozygotes for Hb E/α-thalassemia 1 (1.7%, homozygous Hb E without α-thalassemia (0.9%, and homozygous Hb E with heterozygous α-thalassemia 2 (0.9%. The usefulness of thalassemia screening is not only for receiving highly effective red blood cells in the recipients but also for encouraging the control and prevention program of thalassemia in blood donors.

  11. Thalassemia and Hemoglobin E in Southern Thai Blood Donors

    Science.gov (United States)

    Kruachan, Kwanta; Sengking, Warachaya; Horpet, Dararat; Sungyuan, Ubol

    2014-01-01

    Thalassemia and hemoglobin E (Hb E) are common in Thailand. Individuals with thalassemia trait usually have a normal hemoglobin concentration or mild anemia. Therefore, thalassemic individuals who have minimum acceptable Hb level may be accepted as blood donors. This study was aimed at determining the frequency of α-thalassemia 1 trait, β-thalassemia trait, and Hb E-related syndromes in Southern Thai blood donors. One hundred and sixteen voluntary blood donors, Southern Thailand origin, were recruited for thalassemia and Hb E screening by red blood cell indices/dichlorophenolindophenol precipitation test. β-Thalassemia and Hb E were then identified by high performance liquid chromatography and 4 common α-thalassemia deletions were characterized by a single tube-multiplex gap-polymerase chain reaction. Overall frequency of hemoglobinopathies was 12.9%, classified as follows: homozygous α-thalassemia 2 (1.7%), heterozygous α-thalassemia 1 (1.7%), heterozygous β-thalassemia without α-thalassemia (0.9%), heterozygous Hb E without α-thalassemia (5.2%), double heterozygotes for Hb E/α-thalassemia 1 (1.7%), homozygous Hb E without α-thalassemia (0.9%), and homozygous Hb E with heterozygous α-thalassemia 2 (0.9%). The usefulness of thalassemia screening is not only for receiving highly effective red blood cells in the recipients but also for encouraging the control and prevention program of thalassemia in blood donors. PMID:25050123

  12. Smartphone-based audiometric test for screening hearing loss in the elderly.

    Science.gov (United States)

    Abu-Ghanem, Sara; Handzel, Ophir; Ness, Lior; Ben-Artzi-Blima, Miri; Fait-Ghelbendorf, Karin; Himmelfarb, Mordechai

    2016-02-01

    Hearing loss is widespread among the elderly. One of the main obstacles to rehabilitation is identifying individuals with potentially correctable hearing loss. Smartphone-based hearing tests can be administered at home, thus greatly facilitating access to screening. This study evaluates the use of a smartphone application as a screening tool for hearing loss in individuals aged ≥ 65 years. Twenty-six subjects aged 84.4 ± 6.73 years (mean ± SD) were recruited. Pure-tone audiometry was administered by both a smartphone application (uHear for iPhone, v1.0 Unitron, Canada) and a standard portable audiometer by trained personnel. Participants also completed a questionnaire on their hearing. Pure-tone thresholds were compared between the two testing modalities and correlated with the questionnaire results. The cutoff point for failing screening tests was a pure tone average of 40 dB for the frequencies 250-6,000 Hz. The smartphone application's pure tone thresholds were higher (poorer hearing) than the audiometric thresholds, with a significant difference in all frequencies but 2,000 Hz. The application and the audiometric values were in agreement for 24 subjects (92 %). The application had a sensitivity of 100 % and specificity of 60 % for screening compared with the audiometer. The questionnaire was significantly less accurate, having assigned a passing score to three participants who failed both the application and audiometric tests. While a smartphone application may not be able to accurately determine the level of hearing impairment, it is useful as a highly accessible portable audiometer substitute for screening for hearing loss in elderly populations.

  13. Primary care validation of a single-question alcohol screening test.

    Science.gov (United States)

    Smith, Peter C; Schmidt, Susan M; Allensworth-Davies, Donald; Saitz, Richard

    2009-07-01

    Unhealthy alcohol use is prevalent but under-diagnosed in primary care settings. To validate, in primary care, a single-item screening test for unhealthy alcohol use recommended by the National Institute on Alcohol Abuse and Alcoholism (NIAAA). Cross-sectional study. Adult English-speaking patients recruited from primary care waiting rooms. Participants were asked the single screening question, “How many times in the past year have you had X or more drinks in a day?”, where X is 5 for men and 4 for women, and a response of 1 or greater [corrected] is considered positive. Unhealthy alcohol use was defined as the presence of an alcohol use disorder, as determined by a standardized diagnostic interview, or risky consumption, as determined using a validated 30-day calendar method. Of 394 eligible primary care patients, 286 (73%) completed the interview. The single-question screen was 81.8% sensitive (95% confidence interval (CI) 72.5% to 88.5%) and 79.3% specific (95% CI 73.1% to 84.4%) for the detection of unhealthy alcohol use. It was slightly more sensitive (87.9%, 95% CI 72.7% to 95.2%) but was less specific (66.8%, 95% CI 60.8% to 72.3%) for the detection of a current alcohol use disorder. Test characteristics were similar to that of a commonly used three-item screen, and were affected very little by subject demographic characteristics. The single screening question recommended by the NIAAA accurately identified unhealthy alcohol use in this sample of primary care patients. These findings support the use of this brief screen in primary care.

  14. Testing the reliability of the Fall Risk Screening Tool in an elderly ambulatory population.

    Science.gov (United States)

    Fielding, Susan J; McKay, Michael; Hyrkas, Kristiina

    2013-11-01

    To identify and test the reliability of a fall risk screening tool in an ambulatory outpatient clinic. The Fall Risk Screening Tool (Albert Lea Medical Center, MN, USA) was scripted for an interview format. Two interviewers separately screened a convenience sample of 111 patients (age ≥ 65 years) in an ambulatory outpatient clinic in a northeastern US city. The interviewers' scoring of fall risk categories was similar. There was good internal consistency (Cronbach's α = 0.834-0.889) and inter-rater reliability [intra-class correlation coefficients (ICC) = 0.824-0.881] for total, Risk Factor and Client's Health Status subscales. The Physical Environment scores indicated acceptable internal consistency (Cronbach's α = 0.742) and adequate reliability (ICC = 0.688). Two Physical Environment items (furniture and medical equipment condition) had low reliabilities [Kappa (K) = 0.323, P = 0.08; K = -0.078, P = 0.648), respectively. The scripted Fall Risk Screening Tool demonstrated good reliability in this sample. Rewording two Physical Environment items will be considered. A reliable instrument such as the scripted Fall Risk Screening Tool provides a standardised assessment for identifying high fall risk patients. This tool is especially useful because it assesses personal, behavioural and environmental factors specific to community-dwelling patients; the interview format also facilitates patient-provider interaction. © 2013 John Wiley & Sons Ltd.

  15. Forward Genetic Screening Using Behavioral Tests in Zebrafish: A Proof of Concept Analysis of Mutants.

    Science.gov (United States)

    Gerlai, Robert; Poshusta, Tanya L; Rampersad, Mindy; Fernandes, Yohaan; Greenwood, Tammy M; Cousin, Margot A; Klee, Eric W; Clark, Karl J

    2017-01-01

    The zebrafish enjoys several advantages over other model organisms. It is small, easy to maintain, prolific, and numerous genetic tools are available for it. For example, forward genetic screens have allowed investigators to identify important genes potentially involved in a variety of functions from embryogenesis to cancer. However, despite its sophisticated behavioral repertoire, behavioral methods have rarely been utilized in forward genetic screens. Here, we employ a two-tiered strategy, a proof of concept study, to explore the feasibility of behavioral screens. We generated mutant lines using transposon-based insertional mutagenesis, allowing us to bias mutant selection with target genes expressed within the brain. Furthermore, we employed an efficient and fast behavioral pre-selection in which we investigated the locomotory response of 5-day post-fertilization old larval fish to hyperosmotic shock. Based on this assay, we selected five lines for our lower throughput secondary adult behavioral screen. The latter screen utilized tests in which computer animated image presentation and video-tracking-based automated quantification of behavior allowed us to compare heterozygous zebrafish with their wild-type siblings on their responses to a variety of stimuli. We found significant mutation induced adult behavioral alterations in 4 out of the 5 lines analyzed, including changes in response to social or fear inducing stimuli, to handling and novelty, or in habituation to novelty. We discuss the pros and cons of behavioral phenotyping and of the use of different forward genetic methods in biomedical research with zebrafish.

  16. Evaluating the reliability of an injury prevention screening tool: Test-retest study.

    Science.gov (United States)

    Gittelman, Michael A; Kincaid, Madeline; Denny, Sarah; Wervey Arnold, Melissa; FitzGerald, Michael; Carle, Adam C; Mara, Constance A

    2016-10-01

    A standardized injury prevention (IP) screening tool can identify family risks and allow pediatricians to address behaviors. To assess behavior changes on later screens, the tool must be reliable for an individual and ideally between household members. Little research has examined the reliability of safety screening tool questions. This study utilized test-retest reliability of parent responses on an existing IP questionnaire and also compared responses between household parents. Investigators recruited parents of children 0 to 1 year of age during admission to a tertiary care children's hospital. When both parents were present, one was chosen as the "primary" respondent. Primary respondents completed the 30-question IP screening tool after consent, and they were re-screened approximately 4 hours later to test individual reliability. The "second" parent, when present, only completed the tool once. All participants received a 10-dollar gift card. Cohen's Kappa was used to estimate test-retest reliability and inter-rater agreement. Standard test-retest criteria consider Kappa values: 0.0 to 0.40 poor to fair, 0.41 to 0.60 moderate, 0.61 to 0.80 substantial, and 0.81 to 1.00 as almost perfect reliability. One hundred five families participated, with five lost to follow-up. Thirty-two (30.5%) parent dyads completed the tool. Primary respondents were generally mothers (88%) and Caucasian (72%). Test-retest of the primary respondents showed their responses to be almost perfect; average 0.82 (SD = 0.13, range 0.49-1.00). Seventeen questions had almost perfect test-retest reliability and 11 had substantial reliability. However, inter-rater agreement between household members for 12 objective questions showed little agreement between responses; inter-rater agreement averaged 0.35 (SD = 0.34, range -0.19-1.00). One question had almost perfect inter-rater agreement and two had substantial inter-rater agreement. The IP screening tool used by a single individual had excellent

  17. Test-Retest Reliability of a Serious Game for Delirium Screening in the Emergency Department.

    Science.gov (United States)

    Tong, Tiffany; Chignell, Mark; Tierney, Mary C; Lee, Jacques S

    2016-01-01

    Introduction: Cognitive screening in settings such as emergency departments (ED) is frequently carried out using paper-and-pencil tests that require administration by trained staff. These assessments often compete with other clinical duties and thus may not be routinely administered in these busy settings. Literature has shown that the presence of cognitive impairments such as dementia and delirium are often missed in older ED patients. Failure to recognize delirium can have devastating consequences including increased mortality (Kakuma et al., 2003). Given the demands on emergency staff, an automated cognitive test to screen for delirium onset could be a valuable tool to support delirium prevention and management. In earlier research we examined the concurrent validity of a serious game, and carried out an initial assessment of its potential as a delirium screening tool (Tong et al., 2016). In this paper, we examine the test-retest reliability of the game, as it is an important criterion in a cognitive test for detecting risk of delirium onset. Objective: To demonstrate the test-retest reliability of the screening tool over time in a clinical sample of older emergency patients. A secondary objective is to assess whether there are practice effects that might make game performance unstable over repeated presentations. Materials and Methods: Adults over the age of 70 were recruited from a hospital ED. Each patient played our serious game in an initial session soon after they arrived in the ED, and in follow up sessions conducted at 8-h intervals (for each participant there were up to five follow up sessions, depending on how long the person stayed in the ED). Results: A total of 114 adults (61 females, 53 males) between the ages of 70 and 104 years ( M = 81 years, SD = 7) participated in our study after screening out delirious patients. We observed a test-retest reliability of the serious game (as assessed by correlation r -values) between 0.5 and 0.8 across adjacent

  18. Utility of quick oculomotor tests for screening the vestibular system in the subacute and chronic populations.

    Science.gov (United States)

    Cohen, Helen S; Stitz, Jasmine; Sangi-Haghpeykar, Haleh; Williams, Susan P; Mulavara, Ajitkumar P; Peters, Brian T; Bloomberg, Jacob J

    2018-04-01

    The goal of this study was to determine the sensitivity and specificity of some widely used, easily administered clinical tests. Simple tests of oculomotor function have become widely used for clinical screening of patients suspected of having vestibular disorders despite a paucity of evidence showing good statistical support for their use in this highly variable population. Healthy controls with no history of otologic or neurologic disorders (n = 291) were compared to patients with known vestibular disorders (n = 62). All subjects performed passive and active head shaking, un-instrumented head impulse tests (HT), and video head impulse tests (vHIT) recorded with infrared video-oculography. For both passive and active head shaking, using presence/absence of vertigo and of nystagmus, sensitivity was low (<0.40). Sensitivity of presence/absence of saccades on HT was even lower (<0.15). On vHIT, gains were all approximately = 1.0, so sensitivity was very low (approximately 0.15-0.35). Sensitivity and specificity for presence/absence of saccades were moderately poor (less than 0.70). None of these tests are adequate for screening patients in the out-patient clinic for vestibular disorders or for screening people in epidemiologic studies to determine the prevalence of vestibular disorders.

  19. The Clock Drawing Test A review of its accuracy in screening for dementia

    Directory of Open Access Journals (Sweden)

    Ivan Aprahamian

    Full Text Available Abstract The Clock Drawing Test (CDT is a simple neuropsychometric instrument that can be easily applied to assess several cognitive functions. Over the past 20 years, the CDT has aroused considerable interest in its role for the early screening of cognitive impairment, especially in dementia. Although the CDT is considered an accurate test for dementia screening, recent studies including comparisons with structured batteries such as the CAMCOG have shown mixed results. Objectives: To investigate the importance of the CDT compared to other commonly used tests, in the diagnosis of dementia in the elderly; (2 to evaluate the reliability and correlation between available CDT scoring scales from recent studies. Methods: A systematic search in the literature was conducted in September 2008 for studies comparing CDT scoring systems and comparing the CDT with neuropsychiatric batteries. Results: Twelve studies were selected for analyses. Seven of these studies compared CDT scoring scales while five compared the CDT against the CAMCOG and the MMSE. Eight studies found good correlation and reliability between the scales and the other tests. Conclusion: Despite the mixed results in these studies, the CDT appears to be a good screening test for dementia.

  20. Prevalence of human T-lymphotropic virus type I and type II antibody among blood donors in Eastern Saudi Arabia.

    Science.gov (United States)

    Ul-Hassan, Zahoor; Al-Bahrani, Ahmad T; Panhotra, Bodh R

    2004-10-01

    Human T-cell leukemia/lymphoma virus type I and type II (HTLV-I/II) infections can be transfusion associated, leading to tropical paraparesis, myelopathy and other neurological disorders. The aim of this study is to circumvent the risk of transmission through blood transfusion and to describe the prevalence of HTLV-I/II antibody among blood donors of Al-Hasa region and the cost effectiveness of screening blood donors. The study was conducted at the Department of Laboratory and Blood Bank, King Fahad Hospital, Al-Hofuf, Al-Hasa, Kingdom of Saudi Arabia during the period of 1997 to 2003. A total of 47426 blood donors were screened for HTLV-I/II antibody by enzyme-linked immunosorbent assay test, during the 7 years of study period. The positive samples were confirmed by western blot analysis. Overall, HTLV-I antibody positivity (confirmed by western blot) was 3/47426 (0.006%). Out of 3 donors positive for HTLV-I antibody during 1997 to 1998, 2 were expatriates (Indian) and one was native Saudi donor. Human T-cell leukemia/lymphoma virus type I antibody positivity among the native Saudi donors was 1/47426 (0.002%) (2/100000 blood donors). None of the donor were positive for HTLV-II antibody. During the last 5 consecutive years of the study period (1999-2003), none of the donor was positive for HTLV-I/II antibody. Al-Hasa region is non-endemic for HTLV-I/II virus infections. Screening of native Saudi blood donors for these viruses does not appear to be cost effective.

  1. DEPIVIH 2: Use of three HIV testing methods in French primary care settings - ELISA laboratory screening versus two rapid point-of-care HIV tests.

    Science.gov (United States)

    Papadima, D; Gauthier, R; Prévoteau du Clary, F; Bouée, S; Conort, G; Livrozet, J-M; Taulera, O; Wajsbrot, A; Majerholc, C; Peter, J-M; Aubert, J-P

    2018-03-01

    The primary endpoint was to evaluate the use of HIV testing methods by French primary care providers: Elisa laboratory screening, instant result HIV diagnostic test and rapid result HIV diagnostic test. The secondary endpoints were the population screening rate of unknown HIV status consulting during the study period, reasons for screening and for choosing the specific screening method, the investigators' satisfaction with the rapid diagnostic test (RDT) and problems encountered. National prospective interventional study with French family physicians (FP) from December 2013 to December 2014. FPs enrolled all consenting adults consulting for an HIV screening test during a 6-month period: the choice was an Elisa laboratory test or one of the two RDTs. During the study period, 43 FPs included 981 patients. HIV screening was performed for the first time for 31.6% of patients; 767 (78.2%) Elisa laboratory test prescriptions and 214 (21.8%) RDTs were performed, leading to a screening rate of 1.3%. For 120 (15.7%) of the Elisa laboratory tests, the result was not reported and six RDTs were not valid. Nine patients were diagnosed as HIV-infected (0.9%): five with Elisa laboratory test and four with RDT. Almost 90% of FPs were willing to keep on using RDTs in their daily practice. In general practice, RDTs may be an important additional tool to traditional HIV screening. They could account for one in five tests prescribed in this context. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  2. POPULATION BASED COLORECTAL CANCER SCREENING: COMPARISON OF TWO FAECAL OCCULT BLOOD TESTS

    Directory of Open Access Journals (Sweden)

    Miren Begoña eZubero

    2014-01-01

    Full Text Available Background: The aim of screening for colorectal cancer is to improve prognosis by the detection of cancer at its early stages. In order to inform the decision on the specific test to be used in the population-based programme in the Basque Autonomous Region (Spain, we compared two immunochemical faecal occult blood quantitative tests (I-FOBT. Methods: Residents of selected study areas, aged 50-69 years, were invited to participate in the screening. Two tests based on latex agglutination (OC-Sensor and FOB Gold were randomly assigned to different study areas. A colonoscopy was offered to patients with a positive test result. The cut-off point used to classify a result as positive, according to manufacturer’s recommendations, was 100 ng/ml for both tests. Results: The invited population included 37,999 individuals. Participation rates were 61.8% (n=11,162 for OC-Sensor and 59.1% (n=11,786 for FOB Gold, (p=0.008. Positive rate for OC-Sensor was 6.6% (n=737 and 8.5% (n=1,002 for FOB Gold, (pConclusions: OC-Sensor test appears to be superior for I-FOBT based CRC screening, given its acceptance, ease of use, associated small number of errors and its screening accuracy. FOB-Gold on the other hand, has higher rate of positive values, with more colonoscopies performed, it shows higher detection incidence rates, but involves more false positives.

  3. An analysis of the duplicate testing strategy of an Irish immunochemical FOBT colorectal cancer screening programme.

    LENUS (Irish Health Repository)

    Kelley, Leanne

    2013-06-10

    AIM: This study examined the relevance of using a two sample quantitative immunochemical faecal occult blood test (iFOBT or FIT) at a high cut off stringency by the first population-based colorectal cancer (CRC) pilot screening programme in Ireland. METHOD: Approximately ten thousand individuals between the ages of 50-74 years were invited to perform two consecutive FITs. These were analysed in tandem using the OC-Sensor and participants with at least one positive result with a haemoglobin cut off for positivity at 100 ng\\/ml were offered colonoscopy. RESULTS: A total of 5023 (52%) (2177 (43%) male; 2846 (57%) female) individuals with a median age of 64 years participated. At least one positive FIT test was detected from 514 (10%) individuals. From the 419 (82%) patients who proceeded to colonoscopy 17 (4%) had CRC and 132(33%) had an advanced adenoma. The detection rate for these screen relevant lesions was 3% (95% CIs = 2.5% - 3.5%) and the FIT positive + colonoscopy detection rate was 36% (95% CI = 31% - 40%). The numbers needed to colonoscope to find an advanced lesion was 2.8. The two test system detected four (23.5%) additional patients with CRC and 37 (28%) with an advanced adenoma compared with a single test. CONCLUSION: The CRC miss rate estimated for a single test (23.5%) was unacceptably high when the goal was to maximize the discovery of advanced lesions in the initial screening round. We conclude that the two test protocol at a high cut off threshold is suitable to optimize FIT screening in Ireland. This article is protected by copyright. All rights reserved.

  4. Deceased Organ Donors With a History of Increased Risk Behavior for the Transmission of Blood-Borne Viral Infection: The UK Experience.

    Science.gov (United States)

    Trotter, Patrick B; Summers, Dominic M; Robb, Matthew; Hulme, William; Ushiro-Lumb, Ines; Watson, Christopher J E; Neuberger, James; Bradley, J Andrew

    2017-07-01

    Deceased organ donors are routinely screened for behaviors that increase the risk of transmissible blood-borne viral (BBV) infection, but the impact of this information on organ donation and transplant outcome is not well documented. Our aim was to establish the impact of such behavior on organ donation and utilization, as well transplant recipient outcomes. We identified all UK deceased organ donors from 2003 to 2015 with a disclosed history of increased risk behavior (IRB) including intravenous drug use (IVDU), imprisonment and increased risk sexual behavior. Of 17 262 potential donors, 659 (3.8%) had IRB for BBV and 285 (1.7%) were seropositive for BBV, of whom half had a history of IRB (mostly IVDU [78.5%]). Of actual donors with IRB, 393 were seronegative for viral markers at time of donation. A history of recent IVDU was associated with fewer potential donors proceeding to become actual organ donors (64% vs 75%, P = 0.007). Donors with IRB provided 1091 organs for transplantation (624 kidneys and 467 other organs). Transplant outcome was similar in recipients of organs from donors with and without IRB. There were 3 cases of unexpected hepatitis C virus transmission, all from an active IVDU donor who was hepatitis C virus seronegative at time of donation, but was found to be viremic on retrospective testing. Donors with a history of IRB provide a valuable source of organs for transplantation with good transplant outcomes and there is scope for increasing the use of organs from such donors.

  5. Knowledge of parents regarding newborn screening test, after accessing the website “Babies’ Portal” - Heel prick test

    Directory of Open Access Journals (Sweden)

    Caroline Antonelli Mendes

    Full Text Available ABSTRACT Purpose: to assess the knowledge of mothers about the heel prick test, develop contents on this test to make it available on the "Babies’ Portal" website, evaluate and validate the informative material developed. Methods: this study was conducted in three stages, that is, the first stage which is about a descriptive study involving 105 mothers of newborn children before performing the neonatal screening "Heel Prick Test", the second one consisting in the development of the website "Babies’ Portal", and the third stage, the evaluation and validation of this material carried out by 20 parents of children between zero and 36 months old, who underwent the neonatal screening Heel Prick Test by accessing the website “Babies’ Portal”. Results: although the interviewed mothers knew that their children had the right to be tested, they showed no knowledge of the diseases that can be prevented, time of diagnosis, nor the consequences arising from the lack of early diagnosis and treatment. The website creation and validation gathered basic information about the Heel Prick Test, and the participants regarded the content from satisfactory to excellent. Conclusion: it is necessary that families know not only about the procedures their children will undergo, but also the reason they are performed and the consequences of failing in doing so.

  6. The donor line break cannula: effect on the donation process, blood component quality and transfusion microbiology testing of an important new blood bag safety feature.

    Science.gov (United States)

    Nightingale, M J; Beard, M J; Bennett, J; Hambleton, R; Ramskill, S; Thomas, S

    2013-08-01

    The use of blood packs with an integral sampling system can result in anti-coagulant from the main bag reaching the sample pouch via the donor line, causing delayed coagulation of blood samples. In NHS Blood and Transplant, this has prevented the use of serum, the preferred matrix for transfusion microbiology (TM) testing, which has led to an increased false positive rate with ethylenediaminetetraacetic acid (EDTA) plasma. There is also a remote possibility of false negative results owing to sample dilution. Manufacturers have responded by offering packs with a donor line break cannula (DLBC) to prevent these adverse effects. The aims of this study were to assess the impact of DLBC packs on donation, blood component quality and of the potential return to serum for TM testing. DLBC packs from three manufacturers were assessed against control packs of the same dimensions and configuration. Donation duration, flow rate, platelet factor 4, prothrombin fragment 1+2, haemolysis and collection and processing incidents were compared. Results indicated no clinically significant adverse effect from the DLBC on the activation state of platelets, the coagulation cascade or increased haemolysis. Donation duration and blood collection and processing incident rates for DLBC packs were not significantly different to controls. The use of DLBC packs would reduce the complexity of manipulations during blood collection and therefore the likelihood of microbially contaminated donations (incorrect skin core diversion) and false negative TM tests. DLBC packs would enable the use of serum for TM testing with a significant reduction in false positive tests compared to EDTA plasma. © 2013 The Authors. Transfusion Medicine © 2013 British Blood Transfusion Society.

  7. Negative HPV screening test predicts low cervical cancer risk better than negative Pap test

    Science.gov (United States)

    Based on a study that included more than 1 million women, investigators at NCI have determined that a negative test for HPV infection compared to a negative Pap test provides greater safety, or assurance, against future risk of cervical cancer.

  8. The King-Devick test as a concussion screening tool administered by sports parents.

    Science.gov (United States)

    Leong, D F; Balcer, L J; Galetta, S L; Liu, Z; Master, C L

    2014-02-01

    Sports-related concussion has received increasing awareness due to short- and long-term neurologic sequelae seen among athletes. The King-Devick (K-D) test captures impairment of eye movements and other correlates of suboptimal brain function. We investigated the K-D test as a screening for concussion when administered by layperson sports parents in a cohort of amateur boxers. The K-D test was administered pre-fight and post-fight by laypersons masked to the head trauma status of each athlete. Matches were watched over by a ringside physician and boxing trainer. Athletes with suspected head trauma received testing with the Military Acute Concussion Evaluation (MACE) by the ringside physician to determine concussion status. Athletes sustaining concussion were compared to the athletes screened using the K-D test. Post-fight K-D scores were lower (better) than the best baseline score (41 vs. 39.3 s, P=0.34, Wilcoxon signed-rank test), in the absence of concussion. One boxer sustained a concussion as determined by the ringside physician. This boxer was accurately identified by the layperson K-D testers due to a worsening in K-D test compared to baseline (3.2 seconds) and an increased number of errors. High levels of test-retest reliability were observed (intraclass correlation coefficient 0.90 [95% CI 0.84-0.97]). Additionally, 6 boxers who participated in multiple bouts showed no worsening of their K-D times further supporting that scores are not affected by the fatigue associated with sparring. The K-D test is a rapid sideline screening tool for concussion that can be effectively administered by non-medically trained laypersons.

  9. Automated Cervical Screening and Triage, Based on HPV Testing and Computer-Interpreted Cytology.

    Science.gov (United States)

    Yu, Kai; Hyun, Noorie; Fetterman, Barbara; Lorey, Thomas; Raine-Bennett, Tina R; Zhang, Han; Stamps, Robin E; Poitras, Nancy E; Wheeler, William; Befano, Brian; Gage, Julia C; Castle, Philip E; Wentzensen, Nicolas; Schiffman, Mark

    2018-04-11

    State-of-the-art cervical cancer prevention includes human papillomavirus (HPV) vaccination among adolescents and screening/treatment of cervical precancer (CIN3/AIS and, less strictly, CIN2) among adults. HPV testing provides sensitive detection of precancer but, to reduce overtreatment, secondary "triage" is needed to predict women at highest risk. Those with the highest-risk HPV types or abnormal cytology are commonly referred to colposcopy; however, expert cytology services are critically lacking in many regions. To permit completely automatable cervical screening/triage, we designed and validated a novel triage method, a cytologic risk score algorithm based on computer-scanned liquid-based slide features (FocalPoint, BD, Burlington, NC). We compared it with abnormal cytology in predicting precancer among 1839 women testing HPV positive (HC2, Qiagen, Germantown, MD) in 2010 at Kaiser Permanente Northern California (KPNC). Precancer outcomes were ascertained by record linkage. As additional validation, we compared the algorithm prospectively with cytology results among 243 807 women screened at KPNC (2016-2017). All statistical tests were two-sided. Among HPV-positive women, the algorithm matched the triage performance of abnormal cytology. Combined with HPV16/18/45 typing (Onclarity, BD, Sparks, MD), the automatable strategy referred 91.7% of HPV-positive CIN3/AIS cases to immediate colposcopy while deferring 38.4% of all HPV-positive women to one-year retesting (compared with 89.1% and 37.4%, respectively, for typing and cytology triage). In the 2016-2017 validation, the predicted risk scores strongly correlated with cytology (P < .001). High-quality cervical screening and triage performance is achievable using this completely automated approach. Automated technology could permit extension of high-quality cervical screening/triage coverage to currently underserved regions.

  10. HPV testing for primary cervical screening: Laboratory issues and evolving requirements for robust quality assurance.

    Science.gov (United States)

    Carozzi, Francesca Maria; Del Mistro, Annarosa; Cuschieri, Kate; Frayle, Helena; Sani, Cristina; Burroni, Elena

    2016-03-01

    This review aims to highlight the importance of Quality Assurance for Laboratories performing HPV test for Cervical Cancer Screening. An HPV test, to be used as primary screening test, must be validated according to international criteria, based on comparison of its clinical accuracy to HC2 or GP5+/6+ PCR-EIA tests. The number of validated platforms is increasing and appropriate Quality Assurance Programs (QAPs) which can interrogate longitudinal robustness and quality are paramount. This document describes the following topics: (1) the characteristics of an HPV laboratory and the personnel training needs, to ensure an elevated quality of the entire process and the optimal use of the resources; (2) the Quality Assurance, as both internal (IQA) and external quality assessment (EQA) systems, to be implemented and performed, and the description of the existing EQAs, including limitations; (3) general considerations for an optimal EQA program for hrHPV primary screening Due to the importance of Quality Assurance for this field, international efforts are necessary to improve QA International Collaboration. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Easier operation and similar power of 10 g monofilament test for screening diabetic peripheral neuropathy.

    Science.gov (United States)

    Zhang, Qi; Yi, Na; Liu, Siying; Zheng, Hangping; Qiao, Xiaona; Xiong, Qian; Liu, Xiaoxia; Zhang, Shuo; Wen, Jie; Ye, Hongying; Zhou, Linuo; Li, Yiming; Hu, Renming; Lu, Bin

    2018-01-01

    Objective The 10 g Semmes-Weinstein monofilament evaluation (SWME) of 4 sites on each foot is recommended for distal symmetric polyneuropathy screening and diagnosis. A similar method has been proposed to diagnose 'high-risk' (for ulceration) feet, using 3 sites per foot. This study compared the effectiveness of SWME for testing 3, 4 and 10 sites per foot to identify patients with diabetic neuropathy. Methods We included 3497 subjects in a SWME of 10 sites; records from the 10-site SWME were used for a SWME of 3 and 4 sites. Neuropathy symptom scores and neuropathy deficit scores were evaluated to identify patients with diabetic peripheral neuropathy. Results The sensitivities of the 10 g SWME for 3, 4 and 10 sites were 17.8%, 19.0% and 22.4%, respectively. The Kappa coefficients for the SWME tests of 3, 4 and 10 sites were high (range: 0.78-0.93). Conclusions There were no significant differences in the effectiveness of 3-, 4- and 10-site SWME testing for diabetic peripheral neuropathy screening. SWME testing of 3 sites on each foot may be sufficient to screen for diabetic neuropathy.

  12. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Science.gov (United States)

    2010-04-01

    ..., free carnitine, and acylcarnitines using tandem mass spectrometry. 862.1055 Section 862.1055 Food and... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

  13. Rapid detection of methicillin resistance in Staphylococcus aureus isolates by the MRSA-screen latex agglutination test

    NARCIS (Netherlands)

    W.B. van Leeuwen (Willem); C. van Pelt (Cindy); A. Luijendijk (Ad); H.A. Verbrugh (Henri); W.H.F. Goessens (Wil)

    1999-01-01

    textabstractThe slide agglutination test MRSA-Screen (Denka Seiken Co., Niigata, Japan) was compared with the mecA PCR ("gold standard") for the detection of methicillin resistance in Staphylococcus aureus. The MRSA-Screen test detected the penicillin-binding protein 2a

  14. De item-reeks van de cognitieve screening test vergeleken met die van de mini-mental state examination

    NARCIS (Netherlands)

    Schmand, B.; Deelman, B. G.; Hooijer, C.; Jonker, C.; Lindeboom, J.

    1996-01-01

    The items of the ¿mini-mental state examination' (MMSE) and a Dutch dementia screening instrument, the ¿cognitive screening test' (CST), as well as the ¿geriatric mental status schedule' (GMS) and the ¿Dutch adult reading test' (DART), were administered to 4051 elderly people aged 65 to 84 years.

  15. Comparison among single-phase test, automated screening method and GC/MS for the traceability of ketamine in urine

    Directory of Open Access Journals (Sweden)

    Alice Visione

    2016-12-01

    CONCLUSION Following the law indications, ketamine is not searched: this limit does not make the authorities able to apply the penalties expected for road laws violations. The automation is essential to guarantee the reliability of toxicological screening tests, especially to medico-legal significance. This results highlight the absolutely necessity of the execution of the confirmation test, successively to screening analysis.

  16. How many cervical cancer cases can potentially be prevented using a more sensitive screening test at young age?

    NARCIS (Netherlands)

    I.M.C.M. de Kok (Inge); J.M. van Rosmalen (Joost); K. Rozemeijer (Kirsten); C. Penning (Corine); M. van Ballegooijen (Marjolein)

    2014-01-01

    textabstractThe human papilloma virus (HPV) DNA test has higher sensitivity than cytology for cervical cancer screening. Therefore, cervical cancer cases that are missed by cytology could potentially be identified if we use primary HPV testing. Studies showed that HPV screening is the preferred

  17. Identification of a cyclin B1-derived CTL epitope eliciting spontaneous responses in both cancer patients and healthy donors

    DEFF Research Database (Denmark)

    Andersen, Rikke Sick; Sørensen, Rikke Bæk; Ritter, Cathrin

    2011-01-01

    . Furthermore, blood from cancer patients and healthy donors was screened for spontaneous T-cell reactivity against the peptide in IFN-γ ELISPOT assays. Patients with breast cancer, malignant melanoma, or renal cell carcinoma hosted powerful and high-frequency T-cell responses against the peptide. In addition......, when blood from healthy donors was tested, similar responses were observed. Ultimately, serum from cancer patients and healthy donors was analyzed for anti-cyclin B1 antibodies. Humoral responses against cyclin B1 were frequently detected in both cancer patients and healthy donors. In conclusion......, a high-affinity cyclin B1-derived HLA-A2-restricted CTL epitope was identified, which was presented on the cell surface of cancer cells, and elicited spontaneous T-cell responses in cancer patients and healthy donors....

  18. Identification of a cyclin B1-derived CTL epitope eliciting spontaneous responses in both cancer patients and healthy donors

    DEFF Research Database (Denmark)

    Andersen, Rikke Sick; Sørensen, Rikke Bæk; Ritter, Cathrin

    2011-01-01

    . Furthermore, blood from cancer patients and healthy donors was screened for spontaneous T-cell reactivity against the peptide in IFN-¿ ELISPOT assays. Patients with breast cancer, malignant melanoma, or renal cell carcinoma hosted powerful and high-frequency T-cell responses against the peptide. In addition......, when blood from healthy donors was tested, similar responses were observed. Ultimately, serum from cancer patients and healthy donors was analyzed for anti-cyclin B1 antibodies. Humoral responses against cyclin B1 were frequently detected in both cancer patients and healthy donors. In conclusion......, a high-affinity cyclin B1-derived HLA-A2-restricted CTL epitope was identified, which was presented on the cell surface of cancer cells, and elicited spontaneous T-cell responses in cancer patients and healthy donors....

  19. The Addenbrooke's Cognitive Examination Revised (ACE-R): a brief cognitive test battery for dementia screening.

    Science.gov (United States)

    Mioshi, Eneida; Dawson, Kate; Mitchell, Joanna; Arnold, Robert; Hodges, John R

    2006-11-01

    There is a clear need for brief, but sensitive and specific, cognitive screening instruments as evidenced by the popularity of the Addenbrooke's Cognitive Examination (ACE). We aimed to validate an improved revision (the ACE-R) which incorporates five sub-domain scores (orientation/attention, memory, verbal fluency, language and visuo-spatial). Standard tests for evaluating dementia screening tests were applied. A total of 241 subjects participated in this study (Alzheimer's disease=67, frontotemporal dementia=55, dementia of Lewy Bodies=20; mild cognitive impairment-MCI=36; controls=63). Reliability of the ACE-R was very good (alpha coefficient=0.8). Correlation with the Clinical Dementia Scale was significant (r=-0.321, pcognitive dysfunction. Copyright (c) 2006 John Wiley & Sons, Ltd.

  20. A comparison of hamstring muscle activity during different screening tests for non-contact ACL injury

    DEFF Research Database (Denmark)

    Husted, Rasmus S; Bencke, Jesper; Andersen, Lars Louis

    2016-01-01

    phenomenon and thereby observable independently of the type of clinical screening tests used is not known. This cross sectional study investigated the rank correlation of knee joint neuromuscular activity between three different ACL injury risk screening tests. METHODS: Sixty-two adolescent female elite......BACKGROUND: Reduced ability to activate the medial hamstring muscles during a sports-specific sidecutting movement has been found to be a potential risk factor for non-contact ACL injury. However, whether a reduced ability to activate the medial hamstring muscle is a general neuromuscular...... football and handball players (16.7±1.3years) participated in the study. Using surface electromyography (EMG) assessment, the neuromuscular activity of medial hamstring muscle (semitendinosus, ST), lateral hamstring muscle (biceps femoris, BF) and quadriceps muscle (vastus lateralis, VL) were monitored...

  1. Follow-up of abnormal or inadequate test results in the Danish Cervical Cancer Screening Program

    DEFF Research Database (Denmark)

    Kristiansen, Bettina Kjær

    2014-01-01

    Denmark has a higher incidence of cervical cancer than other Nordic countries, although all Danish women (aged 23–65) are screened regularly to identify possible cervical dysplasia or asymptomatic invasive cancer. Annually 40 000 women receives an abnormal or inadequate test result and a follow......-up recommendation. However problems with delayed follow-up may threaten the effectiveness of the Danish Cervical Cancer Screening Program, as 20% of women are delayed and dysplasia potentially can progress into cancer. Delayed follow-up is found in situations where women either consciously or unconsciously postpone...... up will be sent to the women (RCT). The intention is to ensure that all women will be notified about the test result, quickly, homogenously and in layman’s written language, still with the opportunity to contact or be contacted by the GP, if there is special needs. Furthermore, it is assumed that GP...

  2. Terrestrial Eco-Toxicological Tests as Screening Tool to Assess Soil Contamination in Krompachy Area

    Science.gov (United States)

    Ol'ga, Šestinová; Findoráková, Lenka; Hančuľák, Jozef; Fedorová, Erika; Tomislav, Špaldon

    2016-10-01

    In this study, we present screening tool of heavy metal inputs to agricultural and permanent grass vegetation of the soils in Krompachy. This study is devoted to Ecotoxicity tests, Terrestrial Plant Test (modification of OECD 208, Phytotoxkit microbiotest on Sinapis Alba) and chronic tests of Earthworm (Dendrobaena veneta, modification of OECD Guidelines for the testing of chemicals 317, Bioaccumulation in Terrestrial Oligochaetes) as practical and sensitive screening method for assessing the effects of heavy metals in Krompachy soils. The total Cu, Zn, As, Pb and Hg concentrations and eco-toxicological tests of soils from the Krompachy area were determined of 4 sampling sites in 2015. An influence of the sampling sites distance from the copper smeltery on the absolutely concentrations of metals were recorded for copper, lead, zinc, arsenic and mercury. The highest concentrations of these metals were detected on the sampling sites up to 3 km from the copper smeltery. The samples of soil were used to assess of phytotoxic effect. Total mortality was established at earthworms using chronic toxicity test after 7 exposure days. The results of our study confirmed that no mortality was observed in any of the study soils. Based on the phytotoxicity testing, phytotoxic effects of the metals contaminated soils from the samples 3KR (7-9) S.alba seeds was observed.

  3. Performance of rapid tests and algorithms for HIV screening in Abidjan, Ivory Coast.

    Science.gov (United States)

    Loukou, Y G; Cabran, M A; Yessé, Zinzendorf Nanga; Adouko, B M O; Lathro, S J; Agbessi-Kouassi, K B T

    2014-01-01

    Seven rapid diagnosis tests (RDTs) of HIV were evaluated by a panel group who collected serum samples from patients in Abidjan (HIV-1 = 203, HIV-2 = 25, HIV-dual = 25, HIV = 305). Kit performances were recorded after the reference techniques (enzyme-linked immunosorbent assay). The following RDTs showed a sensitivity of 100% and a specificity higher than 99%: Determine, Oraquick, SD Bioline, BCP, and Stat-Pak. These kits were used to establish infection screening strategies. The combination with 2 or 3 of these tests in series or parallel algorithms showed that series combinations with 2 tests (Oraquick and Bioline) and 3 tests (Determine, BCP, and Stat-Pak) gave the best performances (sensitivity, specificity, positive predictive value, and negative predictive value of 100%). However, the combination with 2 tests appeared to be more onerous than the combination with 3 tests. The combination with Determine, BCP, and Stat-Pak tests serving as a tiebreaker could be an alternative to the HIV/AIDS serological screening in Abidjan.

  4. Primary care visit use after positive fecal immunochemical test for colorectal cancer screening.

    Science.gov (United States)

    Hillyer, Grace Clarke; Jensen, Christopher D; Zhao, Wei K; Neugut, Alfred I; Lebwohl, Benjamin; Tiro, Jasmin A; Kushi, Lawrence H; Corley, Douglas A

    2017-10-01

    For some patients, positive cancer screening test results can be a stressful experience that can affect future screening compliance and increase the use of health care services unrelated to medically indicated follow-up. Among 483,216 individuals aged 50 to 75 years who completed a fecal immunochemical test to screen for colorectal cancer at a large integrated health care setting between 2007 and 2011, the authors evaluated whether a positive test was associated with a net change in outpatient primary care visit use within the year after screening. Multivariable regression models were used to evaluate the relationship between test result group and net changes in primary care visits after fecal immunochemical testing. In the year after the fecal immunochemical test, use increased by 0.60 clinic visits for patients with true-positive results. The absolute change in visits was largest (3.00) among individuals with positive test results who were diagnosed with colorectal cancer, but significant small increases also were found for patients treated with polypectomy and who had no neoplasia (0.36) and those with a normal examination and no polypectomy performed (0.17). Groups of patients who demonstrated an increase in net visit use compared with the true-negative group included patients with true-positive results (odds ratio [OR], 1.60; 95% confidence interval [95% CI], 1.54-1.66), and positive groups with a colorectal cancer diagnosis (OR, 7.19; 95% CI, 6.12-8.44), polypectomy/no neoplasia (OR, 1.37; 95% CI, 1.27-1.48), and normal examination/no polypectomy (OR, 1.24; 95% CI, 1.18-1.30). Given the large size of outreach programs, these small changes can cumulatively generate thousands of excess visits and have a substantial impact on total health care use. Therefore, these changes should be included in colorectal cancer screening cost models and their causes investigated further. Cancer 2017;123:3744-3753. © 2017 American Cancer Society. © 2017 American Cancer Society.

  5. What women want. Women's preferences for the management of low-grade abnormal cervical screening tests: a systematic review

    DEFF Research Database (Denmark)

    Frederiksen, Maria Eiholm; Lynge, E; Rebolj, M

    2012-01-01

    Please cite this paper as: Frederiksen M, Lynge E, Rebolj M. What women want. Women's preferences for the management of low-grade abnormal cervical screening tests: a systematic review. BJOG 2011; DOI: 10.1111/j.1471-0528.2011.03130.x. Background If human papillomavirus (HPV) testing will replace...... cytology in primary cervical screening, the frequency of low-grade abnormal screening tests will double. Several available alternatives for the follow-up of low-grade abnormal screening tests have similar outcomes. In this situation, women's preferences have been proposed as a guide for management....... Selection criteria Studies asking women to state a preference between active follow-up and observation for the management of low-grade abnormalities on screening cytology or HPV tests. Data collection and analysis Information on study design, participants and outcomes was retrieved using a prespecified form...

  6. Donor-derived Strongyloides stercoralis hyperinfection syndrome after simultaneous kidney/pancreas transplantation

    Directory of Open Access Journals (Sweden)

    A. Galiano

    2016-10-01

    Full Text Available Most cases of strongyloidiasis associated with solid organ transplantation have been due to the reactivation of a latent infection in the recipient as a result of the immunosuppressive therapy; however, donor-derived infections are becoming increasingly frequent. The case of a patient who nearly died of a Strongyloides stercoralis hyperinfection after receiving simultaneous kidney/pancreas transplants is described herein. No specific parasitological tests were performed pre-transplantation, despite the fact that both the recipient and the donor originated from endemic areas. Serological analysis of the donor's serum performed retrospectively revealed the origin of the infection, which if it had been done beforehand would have prevented the serious complications. Current practice guidelines need to be updated to incorporate immunological and molecular techniques for the rapid screening of Strongyloides prior to transplantation, and empirical treatment with ivermectin should be applied systematically when there is the slightest risk of infection in the donor or recipient.

  7. Negative screening tests in classical galactosaemia caused by S135L homozygosity.

    LENUS (Irish Health Repository)

    Crushell, E

    2009-06-01

    Classical galactosaemia is relatively common in Ireland due to a high carrier rate of the Q188R GALT mutation. It is screened for using a bacterial inhibition assay (BIA) for free galactose. A Beutler assay on day one of life is performed only in high risk cases (infants of the Traveller community and relatives of known cases). A 16-month-old Irish-born boy of Nigerian origin was referred for investigation of developmental delay, and failure to thrive. He had oral aversion to solids and his diet consisted of cow\\'s milk and milk-based cereal mixes. He was found to have microcephaly, weight <2nd percentile, hepatomegaly and bilateral cataracts. Coagulation screen was normal and transaminases were slightly elevated. His original newborn screen was reviewed and confirmed to have been negative; urinary reducing substances on three separate occasions were negative. Beutler assay demonstrated "absent" red cell galactose-1-phosphate uridyltransferase (GALT) activity. GALT enzyme activity was <0.5 gsubs\\/h per gHb confirming classical galactosaemia. Gal-1-P was elevated at 1.88 micromol\\/gHb. Mutation analysis of the GALT gene revealed S135L homozygosity. S135L\\/S135L galactosaemia is associated with absent red cell GALT activity but with approximately 10% activity in other tissues such as the liver and intestines, probably explaining the negative screening tests and the somewhat milder phenotype associated with this genotype. The patient was commenced on galactose-restricted diet; on follow-up at 2 years of age, growth had normalized but there was global developmental delay. In conclusion, galactosaemia must be considered in children who present with poor growth, hepatomegaly, developmental delay and cataracts and GALT enzyme analysis should be a first line test in such cases. Non-enzymatic screening methods such as urinary reducing substances and BIA for free galactose are not reliable in S135L homozygous galactosaemia.

  8. The comparative cost-effectiveness of colorectal cancer screening using faecal immunochemical test vs. colonoscopy.

    Science.gov (United States)

    Wong, Martin C S; Ching, Jessica Y L; Chan, Victor C W; Sung, Joseph J Y

    2015-09-04

    Faecal immunochemical tests (FITs) and colonoscopy are two common screening tools for colorectal cancer(CRC). Most cost-effectiveness studies focused on survival as the outcome, and were based on modeling techniques instead of real world observational data. This study evaluated the cost-effectiveness of these two tests to detect colorectal neoplastic lesions based on data from a 5-year community screening service. The incremental cost-effectiveness ratio (ICER) was assessed based on the detection rates of neoplastic lesions, and costs including screening compliance, polypectomy, colonoscopy complications, and staging of CRC detected. A total of 5,863 patients received yearly FIT and 4,869 received colonoscopy. Compared with FIT, colonoscopy detected notably more adenomas (23.6% vs. 1.6%) and advanced lesions or cancer (4.2% vs. 1.2%). Using FIT as control, the ICER of screening colonoscopy in detecting adenoma, advanced adenoma, CRC and a composite endpoint of either advanced adenoma or stage I CRC was US$3,489, US$27,962, US$922,762 and US$23,981 respectively. The respective ICER was US$3,597, US$439,513, -US$2,765,876 and US$32,297 among lower-risk subjects; whilst the corresponding figure was US$3,153, US$14,852, US$184,162 and US$13,919 among higher-risk subjects. When compared to FIT, colonoscopy is considered cost-effective for screening adenoma, advanced neoplasia, and a composite endpoint of advanced neoplasia or stage I CRC.

  9. In Vitro Screening of Environmental Chemicals for Targeted Testing Prioritization: The ToxCast Project

    OpenAIRE

    Judson, Richard S.; Houck, Keith A.; Kavlock, Robert J.; Knudsen, Thomas B.; Martin, Matthew T.; Mortensen, Holly M.; Reif, David M.; Rotroff, Daniel M.; Shah, Imran; Richard, Ann M.; Dix, David J.

    2009-01-01

    Background Chemical toxicity testing is being transformed by advances in biology and computer modeling, concerns over animal use, and the thousands of environmental chemicals lacking toxicity data. The U.S. Environmental Protection Agency?s ToxCast program aims to address these concerns by screening and prioritizing chemicals for potential human toxicity using in vitro assays and in silico approaches. Objectives This project aims to evaluate the use of in vitro assays for understanding the ty...

  10. Do Men and Women Need to Be Screened Differently with Fecal Immunochemical Testing? A Cost-Effectiveness Analysis.

    Science.gov (United States)

    Meulen, Miriam P van der; Kapidzic, Atija; Leerdam, Monique E van; van der Steen, Alex; Kuipers, Ernst J; Spaander, Manon C W; de Koning, Harry J; Hol, Lieke; Lansdorp-Vogelaar, Iris

    2017-08-01

    Background: Several studies suggest that test characteristics for the fecal immunochemical test (FIT) differ by gender, triggering a debate on whether men and women should be screened differently. We used the microsimulation model MISCAN-Colon to evaluate whether screening stratified by gender is cost-effective. Methods: We estimated gender-specific FIT characteristics based on first-round positivity and detection rates observed in a FIT screening pilot (CORERO-1). Subsequently, we used the model to estimate harms, benefits, and costs of 480 gender-specific FIT screening strategies and compared them with uniform screening. Results: Biennial FIT screening from ages 50 to 75 was less effective in women than men [35.7 vs. 49.0 quality-adjusted life years (QALY) gained, respectively] at higher costs (€42,161 vs. -€5,471, respectively). However, the incremental QALYs gained and costs of annual screening compared with biennial screening were more similar for both genders (8.7 QALYs gained and €26,394 for women vs. 6.7 QALYs gained and €20,863 for men). Considering all evaluated screening strategies, optimal gender-based screening yielded at most 7% more QALYs gained than optimal uniform screening and even resulted in equal costs and QALYs gained from a willingness-to-pay threshold of €1,300. Conclusions: FIT screening is less effective in women, but the incremental cost-effectiveness is similar in men and women. Consequently, screening stratified by gender is not more cost-effective than uniform FIT screening. Impact: Our conclusions support the current policy of uniform FIT screening. Cancer Epidemiol Biomarkers Prev; 26(8); 1328-36. ©2017 AACR . ©2017 American Association for Cancer Research.

  11. A comparison of hamstring muscle activity during different screening tests for non-contact ACL injury.

    Science.gov (United States)

    Husted, Rasmus S; Bencke, Jesper; Andersen, Lars L; Myklebust, Grethe; Kallemose, Thomas; Lauridsen, Hanne B; Hölmich, Per; Aagaard, Per; Zebis, Mette K

    2016-06-01

    Reduced ability to activate the medial hamstring muscles during a sports-specific sidecutting movement has been found to be a potential risk factor for non-contact ACL injury. However, whether a reduced ability to activate the medial hamstring muscle is a general neuromuscular phenomenon and thereby observable independently of the type of clinical screening tests used is not known. This cross sectional study investigated the rank correlation of knee joint neuromuscular activity between three different ACL injury risk screening tests. Sixty-two adolescent female elite football and handball players (16.7±1.3years) participated in the study. Using surface electromyography (EMG) assessment, the neuromuscular activity of medial hamstring muscle (semitendinosus, ST), lateral hamstring muscle (biceps femoris, BF) and quadriceps muscle (vastus lateralis, VL) were monitored during three standardized screening tests - i.e. one-legged horizontal hop (OLH), drop vertical jump (DJ) and sidecutting (SC). Neuromuscular pre-activity was measured in the time interval 10ms prior to initial contact on a force plate. For neuromuscular hamstring muscle pre-activity, correlation analysis (Spearman correlation coefficient) showed low-to-moderate correlations between SC and 1) DJ (rs=0.34-0.36, Phamstring pre-activity share some common variance during the examined tests. However, a lack of strong correlation suggests that we cannot generalize one risk factor during one test to another test. The present data demonstrate that one-legged horizontal hop and drop vertical jump testing that are commonly used in the clinical setting does not resemble the specific neuromuscular activity patterns known to exist during sidecutting, a well known high risk movement for non-contact ACL injury. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Screening for cognitive impairment in older individuals. Validation study of a computer-based test.

    Science.gov (United States)

    Green, R C; Green, J; Harrison, J M; Kutner, M H

    1994-08-01

    This study examined the validity of a computer-based cognitive test that was recently designed to screen the elderly for cognitive impairment. Criterion-related validity was examined by comparing test scores of impaired patients and normal control subjects. Construct-related validity was computed through correlations between computer-based subtests and related conventional neuropsychological subtests. University center for memory disorders. Fifty-two patients with mild cognitive impairment by strict clinical criteria and 50 unimpaired, age- and education-matched control subjects. Control subjects were rigorously screened by neurological, neuropsychological, imaging, and electrophysiological criteria to identify and exclude individuals with occult abnormalities. Using a cut-off total score of 126, this computer-based instrument had a sensitivity of 0.83 and a specificity of 0.96. Using a prevalence estimate of 10%, predictive values, positive and negative, were 0.70 and 0.96, respectively. Computer-based subtests correlated significantly with conventional neuropsychological tests measuring similar cognitive domains. Thirteen (17.8%) of 73 volunteers with normal medical histories were excluded from the control group, with unsuspected abnormalities on standard neuropsychological tests, electroencephalograms, or magnetic resonance imaging scans. Computer-based testing is a valid screening methodology for the detection of mild cognitive impairment in the elderly, although this particular test has important limitations. Broader applications of computer-based testing will require extensive population-based validation. Future studies should recognize that normal control subjects without a history of disease who are typically used in validation studies may have a high incidence of unsuspected abnormalities on neurodiagnostic studies.

  13. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    OpenAIRE

    Plumb, Andrew A.; Ghanouni, Alex; Rees, Colin J.; Hewitson, Paul; Nickerson, Claire; Wright, Suzanne; Taylor, Stuart A.; Halligan, Steve; von Wagner, Christian

    2016-01-01

    Objective To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. Methods Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as compl...

  14. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    OpenAIRE

    Plumb, A. A.; Ghanouni, A.; Rees, C. J.; Hewitson, P.; Nickerson, C.; Wright, S.; Taylor, S. A.; Halligan, S.; von Wagner, C.

    2017-01-01

    OBJECTIVE: To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. METHODS: Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as com...

  15. Terrestrial avoidance behaviour tests as screening tool to assess soil contamination

    International Nuclear Information System (INIS)

    Loureiro, Susana; Soares, Amadeu M.V.M.; Nogueira, Antonio J.A.

    2005-01-01

    To assess soil quality and risk assessment, bioassays can be useful tools to gauge the potential toxicity of contaminants focusing on their bioavailable fraction. A rapid and sublethal avoidance behaviour test was used as a screening tool with the earthworm Eisenia andrei and the isopod Porcellionides pruinosus, where organisms were exposed during 48 h to several chemicals (lindane, dimethoate and copper sulphate, for isopods and carbendazim, benomyl, dimethoate and copper sulphate for earthworms). Both species were also exposed to soils from an abandoned mine. For all bioassays a statistical approach was used to derive EC 50 values. Isopods and earthworms were able to perceive the presence of toxic compounds and escaping from contaminated to clean soil. Furthermore the behaviour parameter was equally or more sensitive then other sublethal parameters (e.g. reproduction or growth), expressing the advantages of Avoidance Behaviour Tests as screening tools in ERA. - Avoidance Behaviour Tests with earthworms and isopods can be used as screening tools in the evaluation of soil contamination

  16. Changes in screening behaviors and attitudes toward screening from pre-test genetic counseling to post-disclosure in Lynch syndrome families

    Science.gov (United States)

    Burton-Chase, Allison M.; Hovick, Shelly R.; Peterson, Susan K.; Marani, Salma K.; Vernon, Sally W.; Amos, Christopher I.; Frazier, Marsha L.; Lynch, Patrick M.; Gritz, Ellen R.

    2013-01-01

    Purpose This study examined colonoscopy adherence and attitudes towards colorectal cancer (CRC) screening in individuals who underwent Lynch syndrome genetic counseling and testing. Methods We evaluated changes in colonoscopy adherence and CRC screening attitudes in 78 cancer-unaffected relatives of Lynch syndrome mutation carriers before pre-test genetic counseling (baseline) and at 6 and 12 months post-disclosure of test results (52 mutation-negative, 26 mutation-positive). Results While both groups were similar at baseline, at 12 months post-disclosure, a greater number of mutation-positive individuals had had a colonoscopy compared with mutation-negative individuals. From baseline to 12 months post-disclosure, the mutation-positive group demonstrated an increase in mean scores on measures of colonoscopy commitment, self-efficacy, and perceived benefits of CRC screening, and a decrease in mean scores for perceived barriers to CRC screening. Mean scores on colonoscopy commitment decreased from baseline to 6 months in the mutation-negative group. Conclusion Adherence to risk-appropriate guidelines for CRC surveillance improved after genetic counseling and testing for Lynch syndrome. Mutation-positive individuals reported increasingly positive attitudes toward CRC screening after receiving genetic test results, potentially reinforcing longer term colonoscopy adherence. PMID:23414081

  17. Complex Approach to Thyroid Screening In Regions Adjacent to the Semipalatinsk Test Site Area

    International Nuclear Information System (INIS)

    Zhumadilov, Zh.Sh.; Musinov, D.R.; Vasikovsky, G.G.; Bobokhidze, D.A.; Zhigitaev, T.K.; Abisheva, G.N.

    1998-01-01

    It has been well documented that the thyroid gland is one of the most radiosensitive of organs, especially when exposure occurs during childhood. It is known as well that childhood exposure to radioactive iodine increases thyroid cancer risk. Conducting thyroid screening in regions adjacent to the Semipalatinsk Test Site (STS) area is very important for medical examination, data management and thyroid dose reconstruction. Our experience of thyroid screening based on our screening projects in Kurchatov and several regions adjacent to STS (more than 4,000 screened patients) allowed to work out the most appropriate screening protocol. A retrospective analysis of the results of surgical treatment of the 7,271 patients with thyroid abnormalities in the Semipalatinsk, Pavlodar and Ust-Kamenogorsk regions of Kazakstan and study the histological staging of 7,271 surgically removed thyroid glands was preceded by our thyroid screening projects. Ours is the first study in the Semipalatinsk region that covers the period 1966-1998.Taking into account the onset of population effective doses during 1962, it was decided to distinguish 6 periods of observation. It is known that basic effective equivalent doses for the majority of the region's population were established by radioactive events in the period 1949-1962. This explains our focus on the year 1962, but thyroid dose reconstruction matter as well as other radiation related problems are still in the progress. We need to get the accurate dosimetry data. Selection of study subjects based on the appropriate criteria needed to be adjusted and clarified in accordance with the main goal of the project and radiation related information. All specialists involved in the thyroid screening project, data management, data analyses and interpretation of the results must be trained and must be highly qualified specialists in this field of science and practice. The experiences in Nagasaki, Hiroshima and Chernobyl, and discussions with

  18. The King-Devick test for sideline concussion screening in collegiate football.

    Science.gov (United States)

    Leong, Danielle F; Balcer, Laura J; Galetta, Steven L; Evans, Greg; Gimre, Matthew; Watt, David

    2015-01-01

    Sports-related concussion has received increasing attention as a result of neurologic sequelae seen among athletes, highlighting the need for a validated, rapid screening tool. The King-Devick (K-D) test requires vision, eye movements, language function and attention in order to perform and has been proposed as a promising tool for assessment of concussion. We investigated the K-D test as a sideline screening tool in a collegiate cohort to determine the effect of concussion. Athletes (n=127, mean age 19.6±1.2 years) from the Wheaton College football and men's and women's basketball teams underwent baseline K-D testing at pre-season physicals for the 2012-2013 season. K-D testing was administered immediately on the sidelines for football players with suspected head injury during regular games and changes compared to baseline were determined. Post-season testing was also performed to compare non-concussed athletes' test performance. Concussed athletes (n=11) displayed sideline K-D scores that were significantly higher (worse) than baseline (36.5±5.6s vs. 31.3±4.5s, pWilcoxon signed-rank test). Post-season testing demonstrated improvement of scores and was consistent with known learning effects (35.1±5.2s vs. 34.4±5.0s, pWilcoxon signed-rank test). Test-retest reliability was analyzed between baseline and post-season administrations of the K-D test resulting in high levels of test-retest reliability (intraclass correlation coefficient (ICC)=0.95 [95% Confidence Interval 0.85-1.05]). The data show worsening of K-D test scores following concussion further supporting utility of the K-D test as an objective, reliable and effective sideline visual screening tool to help identify athletes with concussion. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  19. Screening for cognitive dysfunction in Huntington's disease with the clock drawing test.

    Science.gov (United States)

    Terwindt, Paul W; Hubers, Anna A M; Giltay, Erik J; van der Mast, Rose C; van Duijn, Erik

    2016-09-01

    The aim of the study is to investigate the performance of the clock drawing test as a screening tool for cognitive impairment in Huntington's disease (HD) mutation carriers. The performance of the clock drawing test was assessed in 65 mutation carriers using the Shulman and the Freund scoring systems. The mini-mental state examination, the Symbol Digit Modalities Test, the Verbal Fluency Test, and the Stroop tests were used as comparisons for the evaluation of cognitive functioning. Correlations of the clock drawing test with various cognitive tests (convergent validity), neuropsychiatric characteristics (divergent validity) and clinical characteristics were analysed using the Spearman's rank correlation coefficient. Receiver-operator characteristic analyses were performed for the clock drawing test against both the mini-mental state examination and against a composite variable for executive cognitive functioning to assess optimal cut-off scores. Inter-rater reliability was high for both the Shulman and Freund scoring systems (ICC = 0.95 and ICC = 0.90 respectively). The clock drawing tests showed moderate to high correlations with the composite variable for executive cognitive functioning (mean ρ = 0.75) and weaker correlations with the mini-mental state examination (mean ρ = 0.62). Mean sensitivity of the clock drawing tests was 0.82 and mean specificity was 0.79, whereas the mean positive predictive value was 0.66 and the mean negative predictive value was 0.87. The clock drawing test is a suitable screening instrument for cognitive dysfunction in HD, because it was shown to be accurate, particularly so with respect to executive cognitive functioning, and is easy and quick to use. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Implementation of broad screening with Ebola rapid diagnostic tests in Forécariah, Guinea

    Directory of Open Access Journals (Sweden)

    Frantz Jean Louis

    2017-03-01

    Full Text Available Background: Laboratory-enhanced surveillance is critical for rapidly detecting the potential re-emergence of Ebola virus disease. Rapid diagnostic tests (RDT for Ebola antigens could expand diagnostic capacity for Ebola virus disease. Objectives: The Guinean National Coordination for Ebola Response conducted a pilot implementation to determine the feasibility of broad screening of patients and corpses with the OraQuick® Ebola RDT. Methods: The implementation team developed protocols and trained healthcare workers to screen patients and corpses in Forécariah prefecture, Guinea, from 15 October to 30 November 2015. Data collected included number of consultations, number of fevers reported or measured, number of tests performed for patients or corpses and results of confirmatory RT-PCR testing. Data on malaria RDT results were collected for comparison. Feedback from Ebola RDT users was collected informally during supervision visits and forums. Results: There were 3738 consultations at the 15 selected healthcare facilities; 74.6% of consultations were for febrile illness. Among 2787 eligible febrile patients, 2633 were tested for malaria and 1628 OraQuick® Ebola RDTs were performed. A total of 322 OraQuick® Ebola RDTs were conducted on corpses. All Ebola tests on eligible patients were negative. Conclusions: Access to Ebola testing was expanded by the implementation of RDTs in an emergency situation. Feedback from Ebola RDT users and lessons learned will contribute to improving quality for RDT expansion.

  1. The Addenbrooke's Cognitive Examination Revised as a potential screening test for elderly drivers.

    Science.gov (United States)

    Ferreira, Inês S; Simões, Mário R; Marôco, João

    2012-11-01

    Considerable research has shown that neuropsychological tests are predictive of real-world driving ability. The Mini-Mental State Examination (MMSE) is a brief cognitive test that has been commonly used in the assessment of older drivers. However, this test has inherent problems that limit its validity to evaluate cognitive abilities related to driving and to screen for driving impairments in non-demented people. Therefore, it is useful to test new screening instruments that may predict potential unsafe drivers who require an in-depth neuropsychological assessment in a specialised centre. To date, the utility of the Addenbrooke's Cognitive Examination Revised (ACE-R) as an indicator of driving ability has not been established. In the current study, fifty older drivers (mean age=73.1 years) who were referred for a psychological assessment, the protocol of which included the ACE-R, underwent an on-road driving test. Using linear discriminant analyses, the results highlighted the higher classification accuracy of the ACE-R compared to the MMSE score, particularly for detecting unsafe drivers. Measures of visuospatial and executive functions, which are not incorporated in the MMSE score, had an incremental value in the prediction of driving ability. This emerging brief cognitive test may warrant additional study for use in the fitness to drive assessment of older adults. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Applicability of Screening Tests for Oxytetracycline in the Milk of Three Breeds of Goats.

    Science.gov (United States)

    Attaie, Rahmat; Bsharat, Mohammed; Mora-Gutierrez, Adela

    2016-06-01

    Antibiotics are widely used in animal husbandry, and the presence of antibiotic residues in milk is a health hazard. The objectives of this study were to determine residual amounts of oxytetracycline in the milk of three breeds of goats using high-pressure liquid chromatography (HPLC) analysis and screening tests. It was also essential to explore the safe withdrawal period of oxytetracycline in lactating goats and examine the applicability of Charm ROSA and SNAP screening tests. The qualitative results of these tests were compared with the quantitative results of the HPLC method. Fifteen milking does, five each from the Alpine, LaMancha, and Nubian breeds, were selected from the herd at Prairie View A&M University. Milk samples containing antibiotic residues were deproteinized by HCl and acetonitrile, and then oxytetracycline was extracted from the supernatant. The residues of oxytetracycline in goat's milk up to 110 h after injection were qualitatively detected using the Charm ROSA test. Similarly, the SNAP test detected the antibiotic residues in milk up to 110 h after treatment. The HPLC results indicated that oxytetracycline residues in milk from Alpine goats were below the tolerance level (300 ng/ml) 82 h after drug treatment (72 h for LaManchas, 58 h for Nubians); however, the results of the screening tests would indicate longer withdrawal periods for milk from the breeds of goats studied, which would result in economic losses to goat's milk producers. The results of this study also indicated that oxytetracycline was not stable in raw goat's milk at refrigeration temperature or during pasteurization and that the concentrations decreased significantly. Commercial goat's milk is usually exposed to several hours of refrigeration and then to pasteurization. The results of this study indicated that, if oxytetracycline was present in raw goat's milk, the concentration would decrease significantly before it was marketed.

  3. Use of external metabolizing systems when testing for endocrine disruption in the T-screen assay

    International Nuclear Information System (INIS)

    Taxvig, Camilla; Olesen, Pelle Thonning; Nellemann, Christine

    2011-01-01

    Although, it is well-established that information on the metabolism of a substance is important in the evaluation of its toxic potential, there is limited experience with incorporating metabolic aspects into in vitro tests for endocrine disrupters. The aim of the current study was a) to study different in vitro systems for biotransformation of ten known endocrine disrupting chemicals (EDs): five azole fungicides, three parabens and 2 phthalates, b) to determine possible changes in the ability of the EDs to bind and activate the thyroid receptor (TR) in the in vitro T-screen assay after biotransformation and c) to investigate the endogenous metabolic capacity of the GH3 cells, the cell line used in the T-screen assay, which is a proliferation assay used for the in vitro detection of agonistic and antagonistic properties of compounds at the level of the TR. The two in vitro metabolizing systems tested the human liver S9 mix and the PCB-induced rat microsomes gave an almost complete metabolic transformation of the tested parabens and phthalates. No marked difference the effects in the T-screen assay was observed between the parent compounds and the effects of the tested metabolic extracts. The GH3 cells themselves significantly metabolized the two tested phthalates dimethyl phthalate (DMP) and diethyl phthalate (DEP). Overall the results and qualitative data from the current study show that an in vitro metabolizing system using liver S9 or microsomes could be a convenient method for the incorporation of metabolic and toxicokinetic aspects into in vitro testing for endocrine disrupting effects.

  4. Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test.

    Science.gov (United States)

    Ortiz, Daniel A; Loeffelholz, Michael J

    2017-11-01

    A syphilis diagnosis is often aided by the detection of treponemal and nontreponemal antibodies. Automated treponemal antibody detection systems enable high-volume clinical laboratories to perform syphilis screening at a faster pace with lower labor costs. The Lumipulse G TP-N chemiluminescent immunoassay is an automated system that qualitatively detects IgG and IgM antibodies against Treponema pallidum antigens in human serum and plasma. To assess performance characteristics and workflow efficiency, the Lumipulse G TP-N assay was compared to the Bioplex 2200 Syphilis IgG multiplex flow immunoassay. Among the 4,134 routine and HIV samples tested by the two automated assays, the percentage of agreement was excellent at 99.0% (95% confidence interval [CI], 98.6% to 99.2%; κ, 0.89), with the Lumipulse G TP-N having a shorter time to first and subsequent results. All specimens with reactive syphilis screening results were further tested by rapid plasma reagin (RPR) and Treponema pallidum particle agglutination (TP·PA) testing ( n = 231). The results from the RPR-reactive samples ( n = 82) showed complete concordance with the two automated assays, while the TP·PA assay displayed some discrepancies. The positive percent agreement (PPA) and negative percent agreement (NPA) between the TP·PA test and the Lumipulse G TP-N test were 98.9% and 77.3%, respectively. The Bioplex 2200 Syphilis IgG immunoassay displayed a similar PPA (100%) but a substantially lower NPA (15.9%). Patient chart reviews of discrepant results suggested that the Lumipulse G TP-N assay produced 27 fewer falsely reactive results and can reduce the amount of additional confirmatory RPR and TP·PA testing needed. The analogous performance characteristics of the two automated systems indicate that the Lumipulse G TP-N assay is suitable for high-throughput syphilis screening. Copyright © 2017 American Society for Microbiology.

  5. [Utilization of self-sampling kits for HPV testing in cervical cancer screening - pilot study].

    Science.gov (United States)

    Ondryášová, H; Koudeláková, V; Drábek, J; Vaněk, P; Slavkovský, R; Hajdúch, M

    2015-12-01

    To get initial experience with alternative sampling (self-sampling) for HPV testing as the means of cervical cancer screening program. Original work. Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University in Olomouc. Based on expression of interest, 215 self-sampling kits were posted to women. Evalyn(®) Brush Vaginal swabs obtained by self-sampling were analyzed for the presence of HPV infection by Cobas 4800 HPV (Roche) followed by genotyping using PapilloCheck(®) HPV-Screening (Greiner Bio-One). Sixty women randomly chosen from our sample were sent a questionnaire focused on their experience with self-sampling. One hundred seventy-four of 215 (81%) distributed self-sampling devices have been delivered to analysis. All cervicovaginal swabs were sampled correctly and it was possible to analyze them by Cobas 4800 HPV test. Similarly, 98% (171/174) samples were analyzable by PapilloCheck(®) HPV-Screening.One hundred twenty-five (72%) of 174 tested samples were HPV negative. Low risk HPV infection was detected only in 7 samples (4%), and high risk HPV (hrHPV) infection was present in 42 samples (24%). The most frequently detected hrHPV genotypes were HPV16 (11/42; 26%) and HPV53 (6/42; 14%). HrHPV co-infection was detected in 10 cases, in 5 of them lrHPV infection was find also.Of the 60 questionnaires, 48 (80%) were returned. From this group, 47 (98%) women rated their experience with self-sampling device as good to excellent. User manual of self-sampling device was considered good to excellent by all women (100%). All women also rated the convenience of self-sampling device using as good to excellent. As expected, most of the women (n = 42 [88%]) preferred self-sampling to physician sampling. Cervicovaginal self-sampling leads to valid results of HPV screening using two molecular genetics methods and was accepted by Czech women very well. The self-sampling as an opportunity to participate in cervical cancer

  6. Development of the Thai version of Mini-Cog, a brief cognitive screening test.

    Science.gov (United States)

    Trongsakul, Supaporn; Lambert, Rod; Clark, Allan; Wongpakaran, Nahathai; Cross, Jane

    2015-05-01

    Cognitive impairment, such as dementia, has emerged as the leading public health problem among the elderly. Therefore, early detection of the disorder and providing appropriate healthcare and management is important, particularly, for the patients with comorbid diabetes who require long-term treatment strategies. In Thailand, because of a large number of elderly patients with diabetes, and time constraints in primary care settings, a short and effective cognitive screening test is required. The Mini-Cog is a short and valid cognitive screening test that was specifically designed for use in primary care settings. The present study translated the English language version into a Thai language version, and then measured the interrater reliability and concurrent validity. The processes of cross-language translation were carried out to develop a Thai language version of the Mini-Cog. A total of 21 Thai older adults with type 2 diabetes with a mean aged of 69 ± 7 years were recruited into a study investigating the interrater reliability and concurrent validity of the Mini-Cog Thai version in one primary care center in Thailand. The Mini-Cog Thai version showed a good interrater reliability (K = 0.80, P validity (r = 0.47, P = 0.007, 95% CI 0.37,0.55) with the Mini-Mental State Examination Thai 2002. The findings show that the Thai version of the Mini-Cog is a reliable, performance-based tool in the screening for cognitive function in primary care settings in Thailand. It is recommended that it could be used as a new cognitive screening test for the aging population in the Thai community. © 2014 Japan Geriatrics Society.

  7. Testing the woman abuse screening tool to identify intimate partner violence in Indonesia.

    Science.gov (United States)

    Iskandar, Livia; Braun, Kathryn L; Katz, Alan R

    2015-04-01

    Intimate Partner Violence (IPV) is a global public health problem. IPV prevalence in Indonesia has been estimated to be less than 1%, based on reported cases. It is likely that IPV prevalence is underreported in Indonesia, as it is in many other countries. Screening for IPV has been found to increase IPV identification, but no screening tools are in use in Indonesia. The aim of this study was to test the translated Woman Abuse Screening Tool (WAST) for detecting IPV in Indonesia. The WAST was tested against a diagnostic interview by a trained psychologist on 240 women attending two Primary Health Centers in Jakarta. IPV prevalence and the reliability, sensitivity, and specificity of the WAST were estimated. Prevalence of IPV by diagnostic interview was 36.3%, much higher than published estimates. The most common forms of IPV identified were psychological (85%) and physical abuse (24%). Internal reliability of the WAST was high (α = .801). A WAST score of 13 (out of 24) is the recommended cutoff for identifying IPV, but only 17% of the Indonesian sample scored 13 or higher. Test sensitivity of the WAST with a cutoff score of 13 was only 41.9%, with a specificity of 96.8%. With a cutoff score of 10, the sensitivity improved to 84.9%, while the specificity decreased to 61.0%. Use of the WAST with a cutoff score of 10 provides good sensitivity and reasonable specificity and would provide a much-needed screening tool for use in Indonesia. Although a lower cutoff would yield a greater proportion of false positives, most of the true cases would be identified, increasing the possibility that women experiencing abuse would receive needed assistance. © The Author(s) 2014.

  8. The minimum test battery to screen for binocular vision anomalies: report 3 of the BAND study.

    Science.gov (United States)

    Hussaindeen, Jameel Rizwana; Rakshit, Archayeeta; Singh, Neeraj Kumar; Swaminathan, Meenakshi; George, Ronnie; Kapur, Suman; Scheiman, Mitchell; Ramani, Krishna Kumar

    2018-03-01

    This study aims to report the minimum test battery needed to screen non-strabismic binocular vision anomalies (NSBVAs) in a community set-up. When large numbers are to be screened we aim to identify the most useful test battery when there is no opportunity for a more comprehensive and time-consuming clinical examination. The prevalence estimates and normative data for binocular vision parameters were estimated from the Binocular Vision Anomalies and Normative Data (BAND) study, following which cut-off estimates and receiver operating characteristic curves to identify the minimum test battery have been plotted. In the receiver operating characteristic phase of the study, children between nine and 17 years of age were screened in two schools in the rural arm using the minimum test battery, and the prevalence estimates with the minimum test battery were found. Receiver operating characteristic analyses revealed that near point of convergence with penlight and red filter (> 7.5 cm), monocular accommodative facility ( 1.25 prism dioptres) were significant factors with cut-off values for best sensitivity and specificity. This minimum test battery was applied to a cohort of 305 children. The mean (standard deviation) age of the subjects was 12.7 (two) years with 121 males and 184 females. Using the minimum battery of tests obtained through the receiver operating characteristic analyses, the prevalence of NSBVAs was found to be 26 per cent. Near point of convergence with penlight and red filter > 10 cm was found to have the highest sensitivity (80 per cent) and specificity (73 per cent) for the diagnosis of convergence insufficiency. For the diagnosis of accommodative infacility, monocular accommodative facility with a cut-off of less than seven cycles per minute was the best predictor for screening (92 per cent sensitivity and 90 per cent specificity). The minimum test battery of near point of convergence with penlight and red filter, difference between distance and near

  9. Routine screening of blood donations at Qingdao central blood bank, China, for hepatitis B virus (HBV) DNA with a real-time, multiplex nucleic acid test for HBV, hepatitis C virus, and human immunodeficiency virus Types 1 and 2.

    Science.gov (United States)

    Yang, Zhongsi; Xu, Lei; Liu, Li; Feng, Qiuxia; Zhang, Longmu; Ma, Weijuan; Saldanha, John; Wang, Mingmin; Zhao, Lin

    2013-10-01

    The Roche cobas TaqScreen MPX test was used to evaluate the rate of hepatitis B surface antigen (HBsAg)-negative donations that were hepatitis B virus (HBV) DNA reactive from June 2010 to January 2011 in Qingdao, China. HBsAg-negative samples from 65,800 voluntary blood donors were tested with the cobas TaqScreen MPX test in pools of 6 on the Roche cobas s 201 blood screening platform. Samples positive for HBV DNA and negative for HBsAg were quantitated with the Roche COBAS AmpliPrep/COBAS TaqMan HBV test. In addition, serologic tests for HBsAg, hepatitis B surface antibody, anti-hepatitis B core antigen (anti-HBc), anti-hepatitis B e antigen (anti-HBe), and hepatitis B e antigen (HBe) were done using the Roche electrochemiluminescence immunoassay. A total of 80 nucleic acid amplification technology (NAT) test-reactive pools were identified and 59 pools (74%) resolved to a reactive sample. All samples were HBV DNA reactive and the viral load in each sample was quantitated. The viral loads of the samples ranged from less than 20 to 34,600 IU/mL; 13 samples (22%) had viral loads of more than 20 IU/mL, 27 samples (45.8%) had viral loads of less than 20 IU/mL, and 19 samples (32.2%) had undetectable viral loads. Of the 59 NAT-reactive samples, 40 (67.8%) were anti-HBc positive. Fifteen of the 59 samples could not be confirmed as NAT reactive either by an alternative NAT test or by serology. The HBV NAT yield in blood donors in Qingdao is 0.06% (38/65,800). This study confirmed the value of NAT for interdicting HBV-positive donations and preventing transfusion-transmitted HBV infections. © 2013 American Association of Blood Banks.

  10. Is the Screening Test of the French Version of the Dementia Quality of Life Questionnaire Indispensable

    Directory of Open Access Journals (Sweden)

    A. Wolak

    2011-04-01

    Full Text Available The aim of this study was to evaluate the usefulness of the screening questions in the French version of the Dementia Quality of Life (DQoL questionnaire. To assess the psychometric properties of the French DQoL, 155 patients with mild-to-moderate dementia were recruited. Here, we compared the psychometric properties of the instrument between patients who passed the screening test (n = 109 and the whole study population (n = 155. The French DQoL version showed a good test-retest reliability at a 2-week interval (0.95 ≤ intraclass correlation coefficients ≤ 1.0, and an average internal consistency (0.58 ≤ Cronbach’s α ≤ 0.87 for the 2 study groups. Significant differences were observed in the 2 groups for 4 dimensions of the DQoL regarding dementia severity (Cornell scale, and for 3 dimensions evaluating depression (MMSE. Convergent validity with the Duke Health Profile revealed many significant correlations between dimensions not only in the 109 patients, but also in the whole study population. Our study demonstrated that patients who failed the screening procedure nonetheless seemed to be able to answer the DQoL questionnaire, the whole study group showing acceptable psychometric properties.

  11. Elevated serum CA 19-9 at screening tests: underlying conditions and role of abdominopelvic CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Yang [University of Louisville, Department of Radiology and Molecular Imaging Research Center, Louisville, KY (United States); Seoul National University Hospital, Department of Radiology, Healthcare System Gangnam Center, Seoul (Korea, Republic of); Kim, Se Hyung [Seoul National University Hospital, Department of Radiology and the Institute of Radiation Medicine, Seoul (Korea, Republic of); Kim, Soo Young [Seoul National University Hospital, Department of Radiology, Healthcare System Gangnam Center, Seoul (Korea, Republic of); Bundang CHA Hospital, Department of Radiology, Bundang (Korea, Republic of)

    2014-10-15

    To investigate underlying conditions of patients with elevated CA 19-9 at screening tests and to evaluate diagnostic performance of abdominopelvic CT. One hundred and thirteen patients with elevated CA 19-9 (>37 U/ml) who underwent abdominopelvic CT in a screening program were selected. Underlying conditions were determined by reviewing all available data and follow-up records. Patients were categorized into malignancy, benign, and normal/non-related disease groups. Their mean CA 19-9 and percent of patients with CA 19-9 ≥ 100 U/ml were compared. Diagnostic sensitivity of CT for detecting underlying conditions of elevated CA 19-9 was analysed. Seventeen patients (17/113, 15 %) had 17 elevated CA 19-9-related malignancies, and 55 patients (55/113, 48.7 %) had 70 benign diseases. Mean CA 19-9 and percent of patients with CA 19-9 ≥ 100 U/ml in the malignancy group were significantly higher than in the two other groups. CT detected all except one malignant lesion with a detection sensitivity of 94.1 % (16/17). Of 70 CA 19-9-related benign diseases, CT detected 34 benign diseases (48.6 %) providing an alternative diagnosis for elevated CA 19-9. Abdominopelvic CT is not only useful in detecting malignancies, but can also diagnose alternative benign causes of elevated CA 19-9 in asymptomatic screening tests. (orig.)

  12. Type 2 Diabetes Screening Test by Means of a Pulse Oximeter.

    Science.gov (United States)

    Moreno, Enrique Monte; Lujan, Maria Jose Anyo; Rusinol, Montse Torrres; Fernandez, Paqui Juarez; Manrique, Pilar Nunez; Trivino, Cristina Aragon; Miquel, Magda Pedrosa; Rodriguez, Marife Alvarez; Burguillos, M Jose Gonzalez

    2017-02-01

    In this paper, we propose a method for screening for the presence of type 2 diabetes by means of the signal obtained from a pulse oximeter. The screening system consists of two parts: the first analyzes the signal obtained from the pulse oximeter, and the second consists of a machine-learning module. The system consists of a front end that extracts a set of features form the pulse oximeter signal. These features are based on physiological considerations. The set of features were the input of a machine-learning algorithm that determined the class of the input sample, i.e., whether the subject had diabetes or not. The machine-learning algorithms were random forests, gradient boosting, and linear discriminant analysis as benchmark. The system was tested on a database of [Formula: see text] subjects (two samples per subject) collected from five community health centers. The mean receiver operating characteristic area found was [Formula: see text]% (median value [Formula: see text]% and range [Formula: see text]%), with a specificity =  [Formula: see text]% for a threshold that gave a sensitivity = [Formula: see text]%. We present a screening method for detecting diabetes that has a performance comparable to the glycated haemoglobin (haemoglobin A1c HbA1c) test, does not require blood extraction, and yields results in less than 5 min.

  13. Economic Evaluations of Pharmacogenetic and Pharmacogenomic Screening Tests: A Systematic Review. Second Update of the Literature.

    Directory of Open Access Journals (Sweden)

    Elizabeth J J Berm

    Full Text Available Due to extended application of pharmacogenetic and pharmacogenomic screening (PGx tests it is important to assess whether they provide good value for money. This review provides an update of the literature.A literature search was performed in PubMed and papers published between August 2010 and September 2014, investigating the cost-effectiveness of PGx screening tests, were included. Papers from 2000 until July 2010 were included via two previous systematic reviews. Studies' overall quality was assessed with the Quality of Health Economic Studies (QHES instrument.We found 38 studies, which combined with the previous 42 studies resulted in a total of 80 included studies. An average QHES score of 76 was found. Since 2010, more studies were funded by pharmaceutical companies. Most recent studies performed cost-utility analysis, univariate and probabilistic sensitivity analyses, and discussed limitations of their economic evaluations. Most studies indicated favorable cost-effectiveness. Majority of evaluations did not provide information regarding the intrinsic value of the PGx test. There were considerable differences in the costs for PGx testing. Reporting of the direction and magnitude of bias on the cost-effectiveness estimates as well as motivation for the chosen economic model and perspective were frequently missing.Application of PGx tests was mostly found to be a cost-effective or cost-saving strategy. We found that only the minority of recent pharmacoeconomic evaluations assessed the intrinsic value of the PGx tests. There was an increase in the number of studies and in the reporting of quality associated characteristics. To improve future evaluations, scenario analysis including a broad range of PGx tests costs and equal costs of comparator drugs to assess the intrinsic value of the PGx tests, are recommended. In addition, robust clinical evidence regarding PGx tests' efficacy remains of utmost importance.

  14. A virtual reality test battery for assessment and screening of spatial neglect.

    Science.gov (United States)

    Fordell, H; Bodin, K; Bucht, G; Malm, J

    2011-03-01

    There is a need for improved screening methods for spatial neglect. To construct a VR-test battery and evaluate its accuracy and usability in patients with acute stroke. VR-DiSTRO consists of a standard desktop computer, a CRT monitor and eye shutter stereoscopic glasses, a force feedback interface, and software, developed to create an interactive and immersive 3D experience. VR-tests were developed and validated to the conventional Star Cancellation test, Line bisection, Baking Tray Task (BTT), and Visual Extinction test. A construct validation to The Rivermead Behavioral Inattention Test, used as criterion of visuospatial neglect, was made. Usability was assessed according to ISO 9241-11. Thirty-one patients with stroke were included, 9/31 patients had neglect. The sensitivity was 100% and the specificity 82% for the VR-DiSTRO to correctly identify neglect. VR-BTT and VR-Extinction had the highest correlation (r² = 0.64 and 0.78), as well as high sensitivity and specificity. The kappa values describing the agreement between traditional neglect tests and the corresponding virtual reality test were between 0.47-0.85. Usability was assessed by a questionnaire; 77% reported that the VR-DiSTRO was 'easy' to use. Eighty-eight percent reported that they felt 'focused', 'pleased' or 'alert'. No patient had adverse symptoms. The test session took 15 min. The VR-DiSTRO quickly and with a high accuracy identified visuospatial neglect in patients with stroke in this construct validation. The usability among elderly patients with stroke was high. This VR-test battery has the potential to become an important screening instrument for neglect and a valuable adjunct to the neuropsychological assessment. © 2010 John Wiley & Sons A/S.

  15. Usability Testing of a National Substance Use Screening Tool Embedded in Electronic Health Records.

    Science.gov (United States)

    Press, Anne; DeStio, Catherine; McCullagh, Lauren; Kapoor, Sandeep; Morley, Jeanne; Conigliaro, Joseph

    2016-07-08

    Screening, brief intervention, and referral to treatment (SBIRT) is currently being implemented into health systems nationally via paper and electronic methods. The purpose of this study was to evaluate the integration of an electronic SBIRT tool into an existing paper-based SBIRT clinical workflow in a patient-centered medical home. Usability testing was conducted in an academic ambulatory clinic. Two rounds of usability testing were done with medical office assistants (MOAs) using a paper and electronic version of the SBIRT tool, with two and four participants, respectively. Qualitative and quantitative data was analyzed to determine the impact of both tools on clinical workflow. A second round of usability testing was done with the revised electronic version and compared with the first version. Personal workflow barriers cited in the first round of testing were that the electronic health record (EHR) tool was disruptive to patient's visits. In Round 2 of testing, MOAs reported favoring the electronic version due to improved layout and the inclusion of an alert system embedded in the EHR. For example, using the system usability scale (SUS), MOAs reported a grade "1" for the statement, "I would like to use this system frequently" during the first round of testing but a "5" during the second round of analysis. The importance of testing usability of various mediums of tools used in health care screening is highlighted by the findings of this study. In the first round of testing, the electronic tool was reported as less user friendly, being difficult to navigate, and time consuming. Many issues faced in the first generation of the tool were improved in the second generation after usability was evaluated. This study demonstrates how usability testing of an electronic SBRIT tool can help to identify challenges that can impact clinical workflow. However, a limitation of this study was the small sample size of MOAs that participated. The results may have been biased to

  16. Cone penetrometer tests and HydroPunch sampling: A screening technique for plume definition

    International Nuclear Information System (INIS)

    Smolley, M.; Kappmeyer, J.C.

    1991-01-01

    Cone penetrometer tests and HydroPunch sampling were used to define the extent of volatile organic compounds in ground water. The investigation indicated that the combination of the these techniques is effective for obtaining ground water samples for preliminary plume definition. HydroPunch samples can be collected in unconsolidated sediments and the analytical results obtained from these samples are comparable to those obtained from adjacent monitoring wells. This sampling method is a rapid and cost-effective screening technique for characterizing the extent of contaminant plumes in soft sediment environments. Use of this screening technique allowed monitoring wells to be located at the plume boundary, thereby reducing the number of wells installed and the overall cost of the plume definition program

  17. Diagnostic dilemma of the single screening test used in the diagnosis of syphilis in Nepal.

    Science.gov (United States)

    Dumre, S P; Shakya, G; Acharya, D; Malla, S; Adhikari, N

    2011-12-01

    Syphilis screening by the nontreponemal rapid plasma reagin (RPR) test is not usually followed up by specific treponemal tests in most of the resource poor healthcare settings of Nepal. We analyzed serum specimens of 504 suspected syphilis cases at the immunology department of the national reference laboratory in Nepal during 2007-2009 using RPR test and Treponema pallidum hemagglutination assay (TPHA). In overall, 35.7% were positive by both methods (combination) while 13.1% were RPR positive and TPHA negative, 8.7% were positive by TPHA only and 42.5% were negative by both methods. Among the RPR reactive (n = 246), 73.2% were positive by TPHA. Non-specific agglutination in RPR testing was relatively higher (26.8%) compared to TPHA (19.6%). Although TPHA was found more specific than RPR test, either of the single tests produced inaccurate diagnosis. Since the single RPR testing for syphilis may yield false positive results, specific treponemal test should be routinely used as confirmatory test to rule out false RPR positive cases. More attention needs to be paid on formulation of strict policy on the implementation of the existing guidelines throughout the country to prevent misdiagnosis in syphilis with the use of single RPR test.

  18. Screening health care workers with interferon-γ release assay versus tuberculin skin test: impact on costs and adherence to testing (the SWITCH study).

    Science.gov (United States)

    Wrighton-Smith, Peter; Sneed, Laurie; Humphrey, Frances; Tao, Xuguang; Bernacki, Edward

    2012-07-01

    To determine the price point at which an interferon-γ release assay (IGRA) is less costly than a tuberculin skin test (TST) for health care employee tuberculosis screening. A multidecision tree-based cost model incorporating inputs gathered from time-motion studies and parallel testing by IGRA and TST was conducted in a subset of our employees. Administering a TST testing program costs $73.20 per person screened, $90.80 per new hire, and $63.42 per annual screen. Use of an IGRA for employee health testing is cost saving at an IGRA test cost of $54.83 or less per test and resulted in higher completion rates because of the elimination of the need for a second visit to interpret the TST. Using an IGRA for employee health screening can be an institutional cost saving and results in higher compliance rates.

  19. Gonosomal mosaicism for an NF1 deletion in a sperm donor

    DEFF Research Database (Denmark)

    Callum, P; Messiaen, L M; Bower, P V

    2012-01-01

    Screening of gamete donors can reduce but cannot eliminate the risks for medical problems in donor-conceived offspring. We present a case of gonosomal mosaicism discovered in an anonymous sperm donor after receiving two reports of neurofibromatosis type 1 (NF1) in donor-conceived offspring...

  20. Nyretransplantation med levende donor

    DEFF Research Database (Denmark)

    Kamper, A L; Løkkegaard, H; Rasmussen, F

    2000-01-01

    In recent years transplantation from living donors has accounted for 25-30% of all kidney transplants in Denmark corresponding to 40-45 per year. Most of these living donors are parents or siblings, although internationally an increasing number are unrelated donors. Donor nephrectomy is associate...... in cadaver transplantation. The ethical and psychological aspects related to transplantation from a living donor are complex and need to be carefully evaluated when this treatment is offered to the patients....

  1. Preseason Functional Movement Screen Component Tests Predict Severe Contact Injuries in Professional Rugby Union Players.

    Science.gov (United States)

    Tee, Jason C; Klingbiel, Jannie F G; Collins, Robert; Lambert, Mike I; Coopoo, Yoga

    2016-11-01

    Tee, JC, Klingbiel, JFG, Collins, R, Lambert, MI, and Coopoo, Y. Preseason Functional Movement Screen component tests predict severe contact injuries in professional rugby union players. J Strength Cond Res 30(11): 3194-3203, 2016-Rugby union is a collision sport with a relatively high risk of injury. The ability of the Functional Movement Screen (FMS) or its component tests to predict the occurrence of severe (≥28 days) injuries in professional players was assessed. Ninety FMS test observations from 62 players across 4 different time periods were compared with severe injuries sustained during 6 months after FMS testing. Mean composite FMS scores were significantly lower in players who sustained severe injury (injured 13.2 ± 1.5 vs. noninjured 14.5 ± 1.4, Effect Size = 0.83, large) because of differences in in-line lunge (ILL) and active straight leg raise scores (ASLR). Receiver-operated characteristic curves and 2 × 2 contingency tables were used to determine that ASLR (cut-off 2/3) was the injury predictor with the greatest sensitivity (0.96, 95% confidence interval [CI] = 0.79-1.0). Adding the ILL in combination with ASLR (ILL + ASLR) improved the specificity of the injury prediction model (ASLR specificity = 0.29, 95% CI = 0.18-0.43 vs. ASLR + ILL specificity = 0.53, 95% CI = 0.39-0.66, p ≤ 0.05). Further analysis was performed to determine whether FMS tests could predict contact and noncontact injuries. The FMS composite score and various combinations of component tests (deep squat [DS] + ILL, ILL + ASLR, and DS + ILL + ASLR) were all significant predictors of contact injury. The FMS composite score also predicted noncontact injury, but no component test or combination thereof produced a similar result. These findings indicate that low scores on various FMS component tests are risk factors for injury in professional rugby players.

  2. The usefulness of esophagography as a screening test for laryngopharyngeal reflux

    International Nuclear Information System (INIS)

    Kim, Tae Hoon; Chung, Phil Sang

    2006-01-01

    There are many articles about the role of barium esophagography for the diagnosis of gastroesophageal reflux disease. However, there are only rare articles reporting on laryngopharyngeal reflux disease. The purpose of this study is to evaluate the usefulness of performing esophagography with the water-siphon test as an initial screening test for patients with suspected laryngopharyngeal reflux. From October 2002 to December 2004, barium esophagography with the water-siphon test was performed for 707 patients who had the typical symptoms and telescopic findings of laryngopharyngeal reflux. The results of the 707 esophagograms (the group with laryngopharyngeal reflux) were compared with those of 122 patients who were confirmed as having gastroesophageal reflux upon performing pH-metry (the group with gastroesophageal reflux) and the 324 patients without laryngopharyngeal reflux symptoms (the control group). The results of the water-siphon test were classified into normal, mild, moderate and severe degrees of gastroesophageal reflux. On the water-siphon test for the laryngopharyneal reflux group patients, 71 patients had normal (10.0%), 207 had mild (29.2%), 201 had moderate (28.4%) and 228 had severe (32.2%) degrees of reflux. The positive rates of the water-siphon test were 90.0%, 89.3% and 54.6% for the groups with laryngopharyngeal reflux, gastroesophageal reflux and the control group, respectively. A statistically significant difference was observed between the group with laryngopharyngeal reflux and the control group, and between the group with gastroesophageal reflux and the control group, respectively (ρ < 0.05). Esophagography with the water-siphon test is useful as an initial screening test for laryngopharyngeal reflux disease

  3. Budget impact analysis of chronic kidney disease mass screening test in Japan.

    Science.gov (United States)

    Kondo, Masahide; Yamagata, Kunihiro; Hoshi, Shu-Ling; Saito, Chie; Asahi, Koichi; Moriyama, Toshiki; Tsuruya, Kazuhiko; Konta, Tsuneo; Fujimoto, Shouichi; Narita, Ichiei; Kimura, Kenjiro; Iseki, Kunitoshi; Watanabe, Tsuyoshi

    2014-12-01

    Our recently published cost-effectiveness study on chronic kidney disease mass screening test in Japan evaluated the use of dipstick test, serum creatinine (Cr) assay or both in specific health checkup (SHC). Mandating the use of serum Cr assay additionally, or the continuation of current policy mandating dipstick test only was found cost-effective. This study aims to examine the affordability of previously suggested reforms. Budget impact analysis was conducted assuming the economic model would be good for 15 years and applying a population projection. Costs expended by social insurers without discounting were counted as budgets. Annual budget impacts of mass screening compared with do-nothing scenario were calculated as ¥79-¥-1,067 million for dipstick test only, ¥2,505-¥9,235 million for serum Cr assay only and ¥2,517-¥9,251 million for the use of both during a 15-year period. Annual budget impacts associated with the reforms were calculated as ¥975-¥4,129 million for mandating serum Cr assay in addition to the currently used mandatory dipstick test, and ¥963-¥4,113 million for mandating serum Cr assay only and abandoning dipstick test. Estimated values associated with the reform from ¥963-¥4,129 million per year over 15 years are considerable amounts of money under limited resources. The most impressive finding of this study is the decreasing additional expenditures in dipstick test only scenario. This suggests that current policy which mandates dipstick test only would contain medical care expenditure.

  4. The usefulness of esophagography as a screening test for laryngopharyngeal reflux

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hoon; Chung, Phil Sang [Dankook University Hospital, Cheonan (Korea, Republic of)

    2006-04-15

    There are many articles about the role of barium esophagography for the diagnosis of gastroesophageal reflux disease. However, there are only rare articles reporting on laryngopharyngeal reflux disease. The purpose of this study is to evaluate the usefulness of performing esophagography with the water-siphon test as an initial screening test for patients with suspected laryngopharyngeal reflux. From October 2002 to December 2004, barium esophagography with the water-siphon test was performed for 707 patients who had the typical symptoms and telescopic findings of laryngopharyngeal reflux. The results of the 707 esophagograms (the group with laryngopharyngeal reflux) were compared with those of 122 patients who were confirmed as having gastroesophageal reflux upon performing pH-metry (the group with gastroesophageal reflux) and the 324 patients without laryngopharyngeal reflux symptoms (the control group). The results of the water-siphon test were classified into normal, mild, moderate and severe degrees of gastroesophageal reflux. On the water-siphon test for the laryngopharyneal reflux group patients, 71 patients had normal (10.0%), 207 had mild (29.2%), 201 had moderate (28.4%) and 228 had severe (32.2%) degrees of reflux. The positive rates of the water-siphon test were 90.0%, 89.3% and 54.6% for the groups with laryngopharyngeal reflux, gastroesophageal reflux and the control group, respectively. A statistically significant difference was observed between the group with laryngopharyngeal reflux and the control group, and between the group with gastroesophageal reflux and the control group, respectively ({rho} < 0.05). Esophagography with the water-siphon test is useful as an initial screening test for laryngopharyngeal reflux disease.

  5. Health Literacy of Living Kidney Donors and Kidney Transplant Recipients

    Science.gov (United States)

    Dageforde, Leigh Anne; Petersen, Alec W.; Feurer, Irene D.; Cavanaugh, Kerri L.; Harms, Kelly A.; Ehrenfeld, Jesse M.; Moore, Derek E.

    2015-01-01

    Background Health literacy (HL) may be a mediator for known socioeconomic and racial disparities in living kidney donation. Methods We evaluated the associations of patient and demographic characteristics with HL in living kidney donors (LD), living donor kidney transplant recipients (LDR), and deceased donor recipients (DDR) in a single center retrospective review of patients undergoing kidney donation or transplantation from September 2010 to July 2012. HL and demographic data were collected. HL was assessed via the Short Literacy Survey (SLS) comprising three self-reported screening questions scored using the 5-point Likert scale [low (3-8), moderate (9-14), high (15)]. Chi-square and logistic regression were used to test factors associated with lower HL. Results The sample included 360 adults (105 LD, 103 LDR, 152 DDR; 46±14 years; 70% white; 56% male; 14±3 years of education). HL scores were skewed (49% high, 41% moderate, 10% low). The distribution of HL categories differed significantly among groups (p=0.019). After controlling for age, race, gender, education and a race-education interaction term, DDR were more likely to have moderate or low HL than LDR (OR 1.911; 95%CI 1.096, 3.332; p=0.022) Conclusions Overall, living donors had high HL. The distribution of low, moderate and high HL differed significantly between LD, DDR and LDR. DDR had a higher likelihood of having low HL than LDR. Screening kidney transplant candidates and donors for lower HL may identify barriers to living donation. Future interventions addressing HL may be important to increase living donation and reduce disparities. PMID:24573114

  6. Implementation of a Computerized Screening Inventory: Improved Usability Through Iterative Testing and Modification.

    Science.gov (United States)

    Boudreaux, Edwin D; Fischer, Andrew Christopher; Haskins, Brianna Lyn; Saeed Zafar, Zubair; Chen, Guanling; Chinai, Sneha A

    2016-03-09

    The administration of health screeners in a hospital setting has traditionally required (1) clinicians to ask questions and log answers, which can be time consuming and susceptible to error, or (2) patients to complete paper-and-pencil surveys, which require third-party entry of information into the electronic health record and can be vulnerable to error and misinterpretation. A highly promising method that avoids these limitations and bypasses third-party interpretation is direct entry via a computerized inventory. To (1) computerize medical and behavioral health screening for use in general medical settings, (2) optimize patient acceptability and feasibility through iterative usability testing and modification cycles, and (3) examine how age relates to usability. A computerized version of 15 screeners, including behavioral health screeners recommended by a National Institutes of Health Office of Behavioral and Social Sciences Research collaborative workgroup, was subjected to systematic usability testing and iterative modification. Consecutive adult, English-speaking patients seeking treatment in an urban emergency department were enrolled. Acceptability was defined as (1) the percentage of eligible patients who agreed to take the assessment (initiation rate) and (2) average satisfaction with the assessment (satisfaction rate). Feasibility was defined as the percentage of the screening items completed by those who initiated the assessment (completion rate). Chi-square tests, analyses of variance, and Pearson correlations were used to detect whether improvements in initiation, satisfaction, and completion rates were seen over time and to examine the relation between age and outcomes. Of 2157 eligible patients approached, 1280 agreed to complete the screening (initiation rate=59.34%). Statistically significant increases were observed over time in satisfaction (F3,1061=3.35, P=.019) and completion rates (F3,1276=25.44, PUsability testing revealed several critical

  7. Cost-effectiveness analysis of the optimal threshold of an automated immunochemical test for colorectal cancer screening: performances of immunochemical colorectal cancer screening.

    Science.gov (United States)

    Berchi, Célia; Guittet, Lydia; Bouvier, Véronique; Launoy, Guy

    2010-01-01

    Most industrialized countries, including France, have undertaken to generalize colorectal cancer screening using guaiac fecal occult blood tests (G-FOBT). However, recent researches demonstrate that immunochemical fecal occult blood tests (I-FOBT) are more effective than G-FOBT. Moreover, new generation I-FOBT benefits from a quantitative reading technique allowing the positivity threshold to be chosen, hence offering the best balance between effectiveness and cost. We aimed at comparing the cost and the clinical performance of one round of screening using I-FOBT at different positivity thresholds to those obtained with G-FOBT to determine the optimal cut-off for I-FOBT. Data were derived from an experiment conducted from June 2004 to December 2005 in Calvados (France) where 20,322 inhabitants aged 50-74 years performed both I-FOBT and G-FOBT. Clinical performance was assessed by the number of advanced tumors screened, including large adenomas and cancers. Costs were assessed by the French Social Security Board and included only direct costs. Screening using I-FOBT resulted in better health outcomes and lower costs than screening using G-FOBT for thresholds comprised between 75 and 93 ng/ml. I-FOBT at 55 ng/ml also offers a satisfactory alternative to G-FOBT, because it is 1.8-fold more effective than G-FOBT, without increasing the number of unnecessary colonoscopies, and at an extra cost of 2,519 euros per advanced tumor screened. The use of an automated I-FOBT at 75 ng/ml would guarantee more efficient screening than currently used G-FOBT. Health authorities in industrialized countries should consider the replacement of G-FOBT by an automated I-FOBT test in the near future.

  8. Validity and Reliability of the Alcohol, Smoking, and Substance Involvement Screening Test (ASSIST) in University Students.

    Science.gov (United States)

    Tiburcio Sainz, Marcela; Rosete-Mohedano, Ma Guadalupe; Natera Rey, Guillermina; Martínez Vélez, Nora Angélica; Carreño García, Silvia; Pérez Cisneros, Daniel

    2016-03-02

    The Alcohol, Smoking and Substance Involvement Screening Test (ASSIST), developed by the World Health Organization (WHO), has been used successfully in many countries, but there are few studies of its validity and reliability for the Mexican population. The objective of this study was to determine the psychometric properties of the self-administered ASSIST test in university students in Mexico. This was an ex post facto non-experimental study with 1,176 undergraduate students, the majority women (70.1%) aged 18-23 years (89.5%) and single (87.5%). To estimate concurrent validity, factor analysis and tests of reliability and correlation were carried out between the subscale for alcohol and AUDIT, those for tobacco and the Fagerström Test, and those for marijuana and DAST-20. Adequate reliability coefficients were obtained for ASSIST subscales for tobacco (alpha = 0.83), alcohol (alpha = 0.76), and marijuana (alpha = 0.73). Significant correlations were found only with the AUDIT (r = 0.71) and the alcohol subscale. The best balance of sensitivity and specificity of the alcohol subscale (83.8% and 80%, respectively) and the largest area under the ROC curve (81.9%) was found with a cutoff score of 8. The self-administered version of ASSIST is a valid screening instrument to identify at-risk cases due to substance use in this population.

  9. Validation of the Danish Addenbrooke's Cognitive Examination as a screening test in a memory clinic.

    Science.gov (United States)

    Stokholm, Jette; Vogel, Asmus; Johannsen, Peter; Waldemar, Gunhild

    2009-01-01

    Addenbrooke's Cognitive Examination (ACE) is a cognitive screening test developed to detect dementia. It has been validated in several countries. Validation studies have predominantly included patients with various degrees of dementia and healthy controls. The aim of this study was to evaluate the Danish version of ACE as a screening test for early dementia in an outpatient memory clinic. Further, we wanted to investigate the ability of the ACE to discriminate patients with early Alzheimer's disease (AD) from patients with depression. 78 patients with mild AD (MMSE >or=20), 30 non-demented patients diagnosed with depression (originally referred for evaluation of cognitive symptoms), and 63 healthy volunteers, all between 60 and 85 years of age, were included. All patients were given the ACE as a supplement to the standard diagnostic work-up. The cut-off points for optimal trade-off between sensitivity and specificity for ACE were 85/86 (sensitivity 0.99, specificity 0.94). When these cut-off points were applied to the group of depressive patients, the specificity dropped to 0.64, indicating a great overlap in individual test scores for demented and depressed patients. The optimal cut-off points for ACE found in this Danish study were close to what is reported in most other European studies. The great overlap in ACE scores for demented and depressed patients emphasize that test scores must be interpreted with great caution when used in diagnostic work-up.

  10. Genetic screening and testing in an episode-based payment model: preserving patient autonomy.

    Science.gov (United States)

    Sutherland, Sharon; Farrell, Ruth M; Lockwood, Charles

    2014-11-01

    The State of Ohio is implementing an episode-based payment model for perinatal care. All costs of care will be tabulated for each live birth and assigned to the delivering provider, creating a three-tiered model for reimbursement for care. Providers will be reimbursed as usual for care that is average in cost and quality, while instituting rewards or penalties for those outside the expected range in either domain. There are few exclusions, and all methods of genetic screening and diagnostic testing are included in the episode cost calculation as proposed. Prenatal ultrasonography, genetic screening, and diagnostic testing are critical components of the delivery of high-quality, evidence-based prenatal care. These tests provide pregnant women with key information about the pregnancy, which, in turn, allows them to work closely with their health care provider to determine optimal prenatal care. The concepts of informed consent and decision-making, cornerstones of the ethical practice of medicine, are founded on the principles of autonomy and respect for persons. These principles recognize that patients' rights to make choices and take actions are based on their personal beliefs and values. Given the personal nature of such decisions, it is critical that patients have unbarred access to prenatal genetic tests if they elect to use them as part of their prenatal care. The proposed restructuring of reimbursement creates a clear conflict between patient autonomy and physician financial incentives.

  11. Performance of the Pentagon Drawing test for the screening of older adults with Alzheimer's dementia

    Directory of Open Access Journals (Sweden)

    José Eduardo Martinelli

    Full Text Available ABSTRACT The Pentagon Drawing Test (PDT is a common cognitive screening test. Objective: The aim of this study was to evaluate performance properties of a specific PDT scoring scale in older adults with Alzheimer's disease (AD and healthy controls. Methods: A cross-sectional study of 390 elderly patients, aged 60 years or older with at least two years of education was conducted. All participants completed clinical and neuropsychological evaluations, including the Cambridge Cognitive Examination, the Mini-Mental State Examination (MMSE, and the Clock Drawing Test. All PDT were blindly scored with the scale of Bourke et al. Results: PDT analyses of the binary score on the MMSE (0 or 1 point did not discriminate AD from controls (p = 0.839. However, when PDT was analyzed using the Bourke et al. scale, the two groups could be distinguished (p <0.001. PDT was not affected by education, showed sensitivity of 85.5% and specificity of 66.9%, discriminated different clinical stages of dementia, and correlated with the other cognitive tests (p <0.001. A 1-point difference on the Bourke et al. scale was associated with an odds ratio of 3.46 for AD. Conclusion: PDT can be used as a cognitive screen for suspected cases of dementia, especially AD, irrespective of educational level.

  12. [Faecal occult blood test for colorectal cancer screening: high quality for a good price].

    Science.gov (United States)

    van Veldhuizen, Harriët; Bonfrer, J M G Hans; Kuipers, Ernst J

    2013-01-01

    The Dutch National Institute for Public Health and the Environment (RIVM) awarded the immunochemical faecal occult blood test (IFOBT) to FOB Gold of Sentinel following a European call for tenders. The contract-awarding procedure included the application of quality knock-out criteria, which were met by two suppliers. The decisive factor was the best price/quality ratio. A recent review indicated that, at present, no single IFOBT is better than any other. The decision to opt for a test manufactured by a different supplier than was used in the previous screening pilots made it necessary to re-determine the cut-off value. This value has now been set (88 ng/ml) and is confirmed by a laboratory test. Colonoscopy-related capacity planning, as well as its diagnostic yield, depends on numerous factors; therefore, the RIVM is currently monitoring the referral percentage and number of adenomas detected and is collaborating on quality terms. Any necessary adjustments are to be made during the introduction of the screening test.

  13. A Chinese version of the Language Screening Test (CLAST for early-stage stroke patients.

    Directory of Open Access Journals (Sweden)

    Hongyan Yang

    Full Text Available There is a severe lack of aphasia screening tools for bedside use in Chinese. A number of aphasia assessment tools have recently been developed abroad, but some of these scales were not suitable for patients with acute stroke. The Language Screening Test (which includes two parallel versions [a/b] in French has been proven to be an effective and time-saving aphasia screening scale for early-stage stroke patients. Therefore, we worked out a Chinese version of the LAST taking into consideration Chinese language and culture. Two preliminary parallel versions (a/b were tested on 154 patients with stroke at acute phase and 107 patients with stroke at non-acute phase, with the Western Aphasia Battery serving as a gold standard. The equivalence between the two parallel versions and the reliability/validity of each version were assessed. The median time to complete one preliminary Chinese version (each had some item redundancy was 98 seconds. Two final parallel versions were established after adjustment/elimination of the redundant items and were found to be equivalent (intra-class correlation coefficient: 0.991. Internal consistency is(Cronbach α for each version [a/b] was 0.956 and 0.965, respectively good. Internal validity was fine: (a no floor or ceiling effect/item redundancy; (b construct validity revealed a 1-dimension structure, just like the French version. The higher educated subjects scored higher than their lower educated counterparts (p<0.01. The external validity: at the optimum cut-off point where the score of version a/b <14 in higher educated group(<13 in lower: the specificity of each version was 0.878/0.902(1/1 in lower and sensitivity was 0.972/0.944(0.944/0.944 in lower. Inter-rater equivalence (intra-class correlation coefficient was 1. The Chinese version of the Language Screening Test was proved to be an efficient and time-saving bedside aphasia screening tool for stroke patients at acute phase and can be used by an average

  14. Opportunistic testing versus organized prostate-specific antigen screening: outcome after 18 years in the Göteborg randomized population-based prostate cancer screening trial.

    Science.gov (United States)

    Arnsrud Godtman, Rebecka; Holmberg, Erik; Lilja, Hans; Stranne, Johan; Hugosson, Jonas

    2015-09-01

    It has been shown that organized screening decreases prostate cancer (PC) mortality, but the effect of opportunistic screening is largely unknown. To compare the ability to reduce PC mortality and the risk of overdiagnosis between organized and opportunistic screening. The Göteborg screening study invited 10 000 randomly selected men for prostate-specific antigen (PSA) testing every 2 yr since 1995, with a prostate biopsy recommended for men with PSA ≥2.5 ng/ml. The control group of 10 000 men not invited has been exposed to a previously reported increased rate of opportunistic PSA testing. Both groups were followed until December 31, 2012. Observed cumulative PC incidence and mortality rates in both groups were calculated using the actuarial method. Using historical data from 1990-1994 (pre-PSA era), we calculated expected PC incidence and mortality rates in the absence of any PSA testing. The number needed to invite (NNI) and the number needed to diagnose (NND) were calculated by comparing the expected versus observed incidence and mortality rates. At 18 yr, 1396 men were diagnosed with PC and 79 men died of PC in the screening group, compared to 962 and 122, respectively, in the control group. In the screening group, the observed cumulative PC incidence/mortality was 16%/0.98% compared to expected values of 6.8%/1.7%. The corresponding values for the control group were 11%/1.5% and 6.9%/1.7%. Organized screening was associated with an absolute PC-specific mortality reduction of 0.72% (95% confidence interval [CI] 0.50-0.94%) and relative risk reduction of 42% (95% CI 28-54%). There was an absolute reduction in PC deaths of 0.20% (95% CI -0.06% to 0.47%) and a relative risk reduction of 12% (95% CI -5 to 26%) associated with opportunistic PSA testing. NNI and NND were 139 (95% CI 107-200) and 13 for organized biennial screening and 493 (95% CI 213- -1563) and 23 for opportunistic screening. The extent of opportunistic screening could not be measured

  15. Mammography and Pap test screening among low-income foreign-born Hispanic women in the USA

    Directory of Open Access Journals (Sweden)

    Fernandez Maria E.

    1998-01-01

    Full Text Available Little is known about the factors influencing screening among low-income Hispanic women particularly among recent immigrants. A sample of 148 low-income, low-literate, foreign-born Hispanic women residing in the Washington DC metropolitan area participated in the study. The mean age of the sample was 46.2 (SD = 11.5, 84% reported annual household incomes<=$15,000. All women were Spanish speakers and had low acculturation levels. Ninety six percent had reported having a Pap smear, but 24% were not in compliance with recommended screening (Pap test within the last 3 years. Among women 40 and older, 62% had received a mammogram, but only 33% were compliant with age appropriate recommended mammography screening guidelines. Women in this study had more misconceptions about cancer than Hispanics in other studies. Multivariate logistic models for correlates of Pap test and mammography screening behavior indicate that factors such as fear of the screening test, embarrassment, and lack of knowledge influenced screening behavior. In conclusion, women in this study had lower rates of mammography screening than non-Hispanic women and lower rates of compliance with recommended Mammography and Pap test screening guidelines.

  16. Impact of gender on decisions to participate in faecal immunochemical test-based colorectal cancer screening: a qualitative study.

    Science.gov (United States)

    Clarke, Nicholas; Gallagher, Pamela; Kearney, Patricia M; McNamara, Deirdre; Sharp, Linda

    2016-12-01

    Faecal immunochemical tests (FITs) are increasingly being used in population-based colorectal cancer-screening programmes. Uptake of FIT is lower in men than women; however, the reasons for this are not well understood. We aimed to explore gender differences in influences on decisions to participate in FIT screening. This is a qualitative study using in-depth face-to-face interviews of four groups of screening invitees (male and female screening users and male and female screening non-users), purposively sampled from the database of a population-based FIT screening programme. Recruitment continued until saturation was reached. Interviews were audio recorded and transcribed verbatim. Thematic analysis using the framework approach was employed with the theoretical domains framework guiding analysis. Forty-seven screening invitees were interviewed. Six theoretical domains influenced screening uptake: 'environmental context and resources', 'beliefs about capabilities', 'beliefs about consequences', 'emotions', 'social influences' and 'knowledge'. Male non-users were often fatalistic, less knowledgeable and misinformed about cancer and FIT screening compared with other groups. Female non-users expressed negative attitudes, beliefs and emotions towards FIT screening, cancer, social influences and the medical profession and were over-confident about their health. Negative attitudes and emotions to screening dominated non-user decision-making but differed by gender. Opportunities to improve uptake in men and women exist. Greater national discussions on the benefits of FIT screening, and development of screening materials tackling negative attitudes and beliefs while recognising male/female differences, may improve screening uptake. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Red Blood Cell Antibody Screen: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... medlineplus.gov/labtests/redbloodcellantibodyscreen.html Red Blood Cell Antibody Screen To use the sharing features on this page, please enable JavaScript. What is an RBC Antibody Screen? An RBC (red blood cell) antibody screen ...

  18. Verification testing of the compression performance of the HEVC screen content coding extensions

    Science.gov (United States)

    Sullivan, Gary J.; Baroncini, Vittorio A.; Yu, Haoping; Joshi, Rajan L.; Liu, Shan; Xiu, Xiaoyu; Xu, Jizheng

    2017-09-01

    This paper reports on verification testing of the coding performance of the screen content coding (SCC) extensions of the High Efficiency Video Coding (HEVC) standard (Rec. ITU-T H.265 | ISO/IEC 23008-2 MPEG-H Part 2). The coding performance of HEVC screen content model (SCM) reference software is compared with that of the HEVC test model (HM) without the SCC extensions, as well as with the Advanced Video Coding (AVC) joint model (JM) reference software, for both lossy and mathematically lossless compression using All-Intra (AI), Random Access (RA), and Lowdelay B (LB) encoding structures and using similar encoding techniques. Video test sequences in 1920×1080 RGB 4:4:4, YCbCr 4:4:4, and YCbCr 4:2:0 colour sampling formats with 8 bits per sample are tested in two categories: "text and graphics with motion" (TGM) and "mixed" content. For lossless coding, the encodings are evaluated in terms of relative bit-rate savings. For lossy compression, subjective testing was conducted at 4 quality levels for each coding case, and the test results are presented through mean opinion score (MOS) curves. The relative coding performance is also evaluated in terms of Bjøntegaard-delta (BD) bit-rate savings for equal PSNR quality. The perceptual tests and objective metric measurements show a very substantial benefit in coding efficiency for the SCC extensions, and provided consistent results with a high degree of confidence. For TGM video, the estimated bit-rate savings ranged from 60-90% relative to the JM and 40-80% relative to the HM, depending on the AI/RA/LB configuration category and colour sampling format.

  19. Biological screening of chitosan derivatives using Artemia spp. (brine shrimp test)

    International Nuclear Information System (INIS)

    Rozaini Mohd Zohdi; Norimah Yusof; Asnah Hassan

    2006-01-01

    The present study reported on the screening of six selected chitosan derivatives using the brine shrimp lethality bioassay. In addition, the irradiation effects towards the compounds at 25 kGy were also studied. Chitosan is a natural polysaccharide derived from chitin, extracted from the exoskeletons of crustaceans and insects as well as walls of some bacteria and fungi. Brine shrimp test is employed for the screening of toxicity of chitosan derivatives. Toxicity test was carried out by adding different concentrations of tested samples to approximately 5 to 15 Artemia salina larvae. Biological activity using the brine shrimp bioassay was recorded as LC 50 i.e. lethal concentration that kills 50% of the larvae within 24 hours of contact with the samples. Compounds are considered toxic when the LC 50 value is lower than 1 mg/ml by brine shrimp bioassay and practically non-toxic when the value is larger. Of the samples tested, none were toxic to the brine shrimp (LC 50 > 1 mg/ml). The LC 50 values of all chitosan derivatives tested, control and irradiated at 25 kGy were above 1 mg/ml thus all tested samples are considered non-toxic. This study demonstrated that irradiation at 25 kGy showed no significant effects towards the toxicity of the chitosan derivatives. After irradiation, only NO-CMC exhibited marked decrease in LC 50 value, reduced by 3-fold from 34.96 mg/ml to 11.07 mg/ml while O-CMC (5.45 mg/ml to 5 mg/ml) showed no clear differences based on rough estimation. This study suggested that brine shrimp bioassay is a simple, reliable and convenient method that could provide useful clues of the relative toxic potential of the sample tested. (Author)

  20. Suitability Screening Test for Marine Corps Air Traffic Controllers Phase 3: Non-cognitive Test Validation and Cognitive Test Prototype

    Science.gov (United States)

    2014-06-01

    developed, pilot tested, and in its Beta form. Findings or Results The subset of NCAPS traits that demonstrated statistically significant prediction for...development and initial pilot testing of the Prototype Marine ATC Cognitive Test. Method The validation approach chosen for this project was a criterion... multitasking ability, and 5) inductive reasoning ability. A working memory capacity test was developed because working memory has been linked to

  1. Development of a fast agglutination screening test (FAST) for the detection of anti-Leishmania antibodies in dogs

    NARCIS (Netherlands)

    Schallig, H. D. F. H.; Schoone, G. J.; Beijer, E. G. M.; Kroon, C. C. M.; Hommers, M.; Ozbel, Y.; Ozensoy, S.; da Silva, E. S.; Cardoso, L. M.; da Silva, E. D.

    2002-01-01

    A fast agglutination screening test (FAST) for the detection of anti-Leishinania antibodies in serum samples from dogs with visceral leishmamosis was developed. The test is based on the direct agglutination test (DAT), but combines a higher parasite concentration with a smaller test volume. In

  2. GAMBARAN ANTI HBc POSITIF PADA DONOR DARAH DENGAN HbsAG NEGATIF

    Directory of Open Access Journals (Sweden)

    Susila Sastri

    2009-09-01

    Ag negatif dan antiHbc positif untuk memastikan darah donor tersebut tidak boleh ditransfusikan.Kata kunci: Skrining, HBV, HBsAg, Anti-HBc, donor darah  Abstract            HBsAg examination alone to screen for hepatitis B (HBV has not been able to guarantee freedom from HBV blood donor so that blood donors have not fulfilled the requirements to be transfused. Blood donors will be transfused donors should qualify them have never suffered from HBV. Screening of blood donors against HBV in the PMI only with HBsAg alone where the HBsAg test is negative at certain stages of HBV, in terms of donors suffering or recovering in HBV. Anti-HBc can provide information on HBV trip when combined with other HBV markers and anti-HBc last longer in the blood compared with other markers. HBsAg negative blood donors with anti-HBc positive than some previous research is still exist that contain HBV-DNA and can transmit HBV.Has done research on blood donors with anti-HBc test descriptively against HBsAg negative blood donors (n = 100 on the UTD PMI Branch of Padang in cross sectional study. Samples taken by proportional random sampling. Blood samples were HBsAg negative blood VDRL, HCV, HIV negative, all examined by the ELISA. The aim is to see the picture of positive anti-HBc in blood donors with HBsAg negative and look at the relationship between the index of HBsAg with anti-HBc index. Examination of anti-HBc by ELISA, equipment and reagents the same output. The results showed the frequency of positive anti-HBc in HBsAg negative blood donors by 27%, especially in men aged between 20-29 years (44.4%. There is a positive correlation between the index of negative HBsAg with anti-HBc index (r = 0.02. Anti-HBc positive are found in HBsAg negative index of 0.21 to 0.60 (76%. In conclusion, blood donors with negative HBsAg have been considered safe for transfusion is still likely to transmit HBV proven by the discovery of anti-HBc positive. Because it needs a further examination of HBV

  3. Development of a simple screening test to detect and determine the microbiological quality of irradiated foods

    International Nuclear Information System (INIS)

    Jones, K.L.; MacPhee, S.M.; Turner, A.J.; Stuckey, T.; Betts, R.P.

    1995-07-01

    The direct epifluorescent filter technique/aerobic plate count (DEFT/APC) method is a recognised technique for the screening of irradiated foods. When the APC of an irradiated sample is compared with the DEFT count on the same sample, the APC is found to be considerably lower than that obtained by the DEFT, thus indicating that the sample could have been irradiated. Since the development of the DEFT/APC screening method, the technique has been tested with a limited range of food products. Previous work has indicated that the storage of irradiated foods can, in certain circumstances, allow microorganisms to grow, and thus compromise the ability of the DEFT/APC method to discriminate between irradiated and unirradiated samples. In some cases the method has been shown to give high DEFT count and low APC with food samples that have not been irradiated. Potentially, foods which have undergone a food processing treatment could give a high DEFT count compared to an APC and be erroneously identified as having been irradiated. The work reported here is aimed at analysing a range of irradiated samples (meat, poultry, fish, seafood, herbs and spices), stored under different conditions, to evaluate the applicability of the screening method for use with such products. The effects of other food processes on the DEFT/APC results were also investigated. (UK)

  4. Personal values that support and counteract utilization of a screening test for prostate cancer.

    Science.gov (United States)

    Aavik, Toivo; Aavik, Anu; Punab, Margus

    2014-01-01

    The main aim of the current research was to discover the personal values that may support men's prostate cancer screening decisions in the future. We asked for participants' past behavior and future behavioral intentions, and also considered their real-life behavior. The sample consisted of 371 men, of which 93 were first-time patients at the Andrology Unit. The results show that Security value was related to past participation, while Achievement, Stimulation, and Traditions counteracted this. Present prostate-testing behavior was related only to higher Security values. Predictors of future behavioral intentions were Security, Self-direction, and Benevolence, which described 21% of the total variability. Considering informed decision-making processes, our results suggest that men who hold Security, Self-direction, and Benevolence values are more likely to participate in office-based initial screening. The study indicates the need to offer office-based initial screening to those age-eligible men whose values do not support participation.

  5. Screening for prostate cancer with the prostate-specific antigen test: are patients making informed decisions?

    Science.gov (United States)

    O'Dell, K J; Volk, R J; Cass, A R; Spann, S J

    1999-09-01

    The benefits of early detection of prostate cancer are uncertain, and the American College of Physicians and the American Academy of Family Physicians recommend individual decision making in prostate cancer screening. This study reports the knowledge of male primary care patients about prostate cancer and prostate-specific antigen (PSA) testing and examines how that knowledge is related to PSA testing, preferences for testing in the future, and desire for involvement in physician-patient decision making. The sample included 160 men aged 45 to 70 years with no history of prostate cancer who presented for care at a university-based family medicine clinic. Before scheduled office visits, patients completed a questionnaire developed for this study that included a 10-question measure of prostate cancer knowledge, the Deber-Kraestchmer Problem-Solving Decision-Making Scale, sociodemographic indicators, and questions on PSA testing. In general, patients who were college graduates were more knowledgeable about prostate cancer and early detection than those with a high school education or less. Aside from college graduates, most patients could not identify the principle advantages and disadvantages of PSA testing. Patients indicating previous or future plans for PSA testing demonstrated greater knowledge than other patients. Desire for involvement in decision making varied by patient education but was not related to past PSA testing. Patients lack knowledge about prostate cancer and early detection. This knowledge deficit may impede the early detection of prostate cancer and is a barrier to making an informed decision about undergoing PSA testing.

  6. The Q* Index: A Useful Global Measure of Dementia Screening Test Accuracy

    Directory of Open Access Journals (Sweden)

    A.J. Larner

    2015-06-01

    Full Text Available Background/Aims: Single, global or unitary, indicators of test diagnostic performance have intuitive appeal for clinicians. The Q* index, the point in receiver operating characteristic (ROC curve space closest to the ideal top left-hand corner and where test sensitivity and specificity are equal, is one such measure. Methods: Datasets from four pragmatic accuracy studies which examined the Mini-Mental State Examination, Addenbrooke's Cognitive Examination-Revised, Montreal Cognitive Assessment, Test Your Memory test, and Mini-Addenbrooke's Cognitive Examination were examined to calculate and compare the Q* index, the maximal correct classification accuracy, and the maximal Youden index, as well as the sensitivity and specificity at these cutoffs. Results: Tests ranked similarly for the Q* index and the area under the ROC curve (AUC ROC. The Q* index cutoff was more sensitive (and less specific than the maximal correct classification accuracy cutoff, and less sensitive (and more specific than the maximal Youden index cutoff. Conclusion: The Q* index may be a useful global parameter summarising the test accuracy of cognitive screening instruments, facilitating comparison between tests, and defining a possible test cutoff value. As the point of equal sensitivity and specificity, its use may be more intuitive and appealing for clinicians than AUC ROC.

  7. Significance of Intratracheal Instillation Tests for the Screening of Pulmonary Toxicity of Nanomaterials.

    Science.gov (United States)

    Morimoto, Yasuo; Izumi, Hiroto; Yoshiura, Yukiko; Fujisawa, Yuri; Fujita, Katsuhide

    Inhalation tests are the gold standard test for the estimation of the pulmonary toxicity of respirable materials. Intratracheal instillation tests have been used widely, but they yield limited evidence of the harmful effects of respirable materials. We reviewed the effectiveness of intratracheal instillation tests for estimating the hazards of nanomaterials, mainly using research papers featuring intratracheal instillation and inhalation tests centered on a Japanese national project. Compared to inhalation tests, intratracheal instillation tests induced more acute inflammatory responses in the animal lung due to a bolus effect regardless of the toxicity of the nanomaterials. However, nanomaterials with high toxicity induced persistent inflammation in the chronic phase, and nanomaterials with low toxicity induced only transient inflammation. Therefore, in order to estimate the harmful effects of a nanomaterial, an observation period of 3 months or 6 months following intratracheal instillation is necessary. Among the endpoints of pulmonary toxicity, cell count and percentage of neutrophil, chemokines for neutrophils and macrophages, and oxidative stress markers are considered most important. These markers show persistent and transient responses in the lung from nanomaterials with high and low toxicity, respectively. If the evaluation of the pulmonary toxicity of nanomaterials is performed in not only the acute but also the chronic phase in order to avoid the bolus effect of intratracheal instillation and inflammatory-related factors that are used as endpoints of pulmonary toxicity, we speculate that intratracheal instillation tests can be useful for screening for the identification of the hazard of nanomaterials through pulmonary inflammation.

  8. Jaw-opening force test to screen for Dysphagia: preliminary results.

    Science.gov (United States)

    Hara, Koji; Tohara, Haruka; Wada, Satoko; Iida, Takatoshi; Ueda, Koichiro; Ansai, Toshihiro

    2014-05-01

    To assess the jaw-opening force test (JOFT) for dysphagia screening. Criterion standard. University dental hospital. Patients complaining of dysphagia (N=95) and with symptoms of dysphagia with chronic underlying causes (mean age ± SD, 79.3±9.61y; range, 50-94y; men: n=49; mean age ± SD, 77.03±9.81y; range, 50-94y; women: n=46; mean age ± SD, 75.42±9.73y; range, 51-93y) admitted for treatment between May 2011 and December 2012 were included. None. All patients were administered the JOFT and underwent fiberoptic endoscopic evaluation of swallowing (FEES). The mean jaw-opening strength was compared with aspiration (ASP) and pharyngeal residue observations of the FEES, which was used as the criterion standard. A receiver operating characteristic (ROC) curve analysis was performed. Forces of ≤3.2kg for men and ≤4kg for women were appropriate cutoff values for predicting ASP with a sensitivity and specificity of .57 and .79 for men and .93 and .52 for women, respectively. Based on the ROC analyses for predicting pharyngeal residue, forces of ≤5.3kg in men and ≤3.9kg in women were appropriate cutoff values, with a sensitivity and specificity of .80 and .88 for men and .83 and .81 for women, respectively. The JOFT could be a useful screening tool for predicting pharyngeal residue and could provide useful information to aid in the referral of patients for further diagnostic imaging testing. However, given its low sensitivity to ASP the JOFT should be paired with other screening tests that predict ASP. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. Hematuria screening test for urinary bladder mucosal infiltration in cervical cancer.

    Science.gov (United States)

    Chuttiangtum, Ayuth; Udomthavornsuk, Banchong; Chumworathayi, Bandit

    2012-01-01

    To determine the diagnostic performance of hematuria as a screening test for urinary bladder infiltration in cervical cancer patients with a prospective study design. Newly diagnosed cervical cancer patients at Srinagarind hospital from 14 June 2011 to 30 April 2012 were enrolled in this study. We collected midstream urine samples for urinalysis from every patient before routine cystoscopic exam for clinical staging. The presence of 3 or more red blood cells (RBCs) per high power field was defined as positive for hematuria. A two-by-two table was used to determine the diagnostic performance of hematuria to detect urinary bladder mucosal infiltration using cystoscopy and biopsy as the gold standard. A total of 130 were patients included, 54 of which (41.5%) had hematuria. Of these, four patients (3.08%) had pathological report from cystoscopic biopsy confirmed metastatic squamous cell carcinoma. The sensitivity, specificity, PPV, NPV, and accuracy of hematuria as a screening test to detect urinary bladder mucosal infiltration of cervical cancer were 100%, 60.3%, 7.4%, 100%, and 61.5%, respectively. There was no single case of urinary bladder mucosal infiltration in patients initially staged less than stage III. Hematuria can be used as a screening test to detect urinary bladder mucosal infiltration of cervical cancer. This can reduce the number of cervical cancer patients who really need to undergo cystoscopy as a staging procedure to less than half and to less than 20% if stage III or more were included without missing a single case of urinary bladder mucosal infiltration.

  10. Six years of vision screening tests in pre-school children in kindergartens of Wroclaw

    Science.gov (United States)

    Szmigiel, Marta; Geniusz, Malwina; Szmigiel, Ireneusz

    2017-09-01

    Detection of vision defects of a child without professional knowledge is not easy. Very often, the parents of a small child does not know that their child sees incorrect. Also the youngster, not knowing any other way of seeing, does not know that it is not the best. While the vision of a small child is not yet fully formed, it is worth checking them very early. Defects detected early gives opportunity for the correction of anomalies, which might give the effect of the normal development of vision. According to the indications, the American Optometric Association (AOA) control eye examination should be performed between the ages of 6 months to 3 years, before going to school and then every two years. Members of SPIE Student Chapter, in cooperation with the Visual Optics Group working on the Department of Optics and Photonics (Faculty of Fundamental Problems, Wroclaw University of Science and Technology) for 6 years offer selected kindergartens of Wroclaw participation in project "Screening vision tests in pre-school children". Depending on the number of involved members of the student chapter and willing to cooperate students of Ophthalmology and Optometry, vision screening test was carried out in up to eight kindergartens every year. The basic purpose of screening vision test is to detect visual defects to start the correction so early in life as possible, while increasing the efficiency of the child's visual potential. The surrounding community is in fact more than enough examples of late diagnose vision problems, which resulted in lack of opportunity or treatment failure

  11. An ImmunoSignature test distinguishes Trypanosoma cruzi, hepatitis B, hepatitis C and West Nile virus seropositivity among asymptomatic blood donors.

    Directory of Open Access Journals (Sweden)

    Michael Rowe

    2017-09-01

    Full Text Available The complexity of the eukaryotic parasite Trypanosoma (T. cruzi manifests in its highly dynamic genome, multi-host life cycle, progressive morphologies and immune-evasion mechanisms. Accurate determination of infection or Chagas' disease activity and prognosis continues to challenge researchers. We hypothesized that a diagnostic platform with higher ligand complexity than previously employed may hold value.We applied the ImmunoSignature Technology (IST for the detection of T. cruzi-specific antibodies among healthy blood donors. IST is based on capturing the information in an individual's antibody repertoire by exposing their peripheral blood to a library of >100,000 position-addressable, chemically-diverse peptides.Initially, samples from two Chagas cohorts declared positive or negative by bank testing were studied. With the first cohort, library-peptides displaying differential binding signals between T. cruzi sero-states were used to train an algorithm. A classifier was fixed and tested against the training-independent second cohort to determine assay performance. Next, samples from a mixed cohort of donors declared positive for Chagas, hepatitis B, hepatitis C or West Nile virus were assayed on the same library. Signals were used to train a single algorithm that distinguished all four disease states. As a binary test, the accuracy of predicting T. cruzi seropositivity by IST was similar, perhaps modestly reduced, relative to conventional ELISAs. However, the results indicate that information beyond determination of seropositivity may have been captured. These include the identification of cohort subclasses, the simultaneous detection and discerning of other diseases, and the discovery of putative new antigens.The central outcome of this study established IST as a reliable approach for specific determination of T. cruzi seropositivity versus disease-free individuals or those with other diseases. Its potential contribution for monitoring and

  12. Results of screening NCI/NTP nongenotoxic carcinogens and genotoxic noncarcinogens with the ke test

    International Nuclear Information System (INIS)

    Mendelsohn, M.L.; Bakale, G.; McCreary, R.D.

    1989-01-01

    The interdependence of the electrophilic and carcinogenic properties of chemicals that was demonstrated two decades ago rekindled interest in the somatic mutation theory of carcinogenesis. Interest in this theory grew with the development of a reverse-mutation bacterial assay in the laboratory of B.N. Ames that permitted the mutagenic properties of the chemicals to be determined quickly and yielded results which indicated that ''carcinogens are mutagens.'' Subsequent validation studies of this bioassay, the Salmonella typhimurium/microsome or ''Ames test,'' by Ames' group and others provided additional support for the correlation between mutagenicity and carcinogenicity which led to the worldwide deployment of the Ames test in thousands of laboratories and to the development of more than 100 other short-term tests that continue to be used to identify potential carcinogens via various end-points of genotoxicity. This document discusses electrophilicity, mutagenicity, and carcinogenicity relationships as well as carcinogen-screening of chemicals. 28 refs., 4 tabs

  13. Reasons for never and intermittent completion of colorectal cancer screening after receiving multiple rounds of mailed fecal tests.

    Science.gov (United States)

    Green, Beverly B; BlueSpruce, June; Tuzzio, Leah; Vernon, Sally W; Aubree Shay, L; Catz, Sheryl L

    2017-05-30

    Long-term adherence to colorectal cancer (CRC) screening is particularly important for fecal testing. Some U.S. studies report that only 25% of individuals repeat fecal testing annually. The purpose of this qualitative study was to identify barriers and facilitators reported by patients with suboptimal screening adherence to refine interventions for starting ongoing adherence to CRC screening. We also explored whether participants, particularly never screeners, would be willing to do a CRC screening blood test. Forty-one patients who previously enrolled in the Systems of Support to Increase CRC Screening (SOS) trial were interviewed 4-5 years later. Participants were purposively selected to include men and women with diverse race/ethnicities who had either been inconsistent screeners or had never screened during the first three years of SOS despite receiving at least two rounds of mailed fecal tests. Two interviewers conducted 30-min telephone interviews using a semi-structured interview guide. An iterative thematic analysis approach was used. Themes related to screening barriers were more pervasive among never screeners including: (1) Avoidance (inattention, procrastination) (2) Concerns about handling stool; (3) Health concerns; (4) Fear of a cancer diagnosis or positive test results. Themes related to screening facilitators were more often mentioned by participants who screened at least once including: (1) Use of a simpler 1-sample fecal test; (2) Convenience of mailings and doing the test at home; (3) Salience of prevention, especially as one got older; and (4) Influence of recommendations from providers, family and friends. Participants had diverse preferences for the number (3 on average) and types (phone, mail, text) of screening reminders. Some participants did not prefer e-mail links to the patient shared electronic health record because of difficulties remembering their password. It was acceptable for a nurse or medical assistant not from their clinic to

  14. Using Relative Statistics and Approximate Disease Prevalence to Compare Screening Tests.

    Science.gov (United States)

    Samuelson, Frank; Abbey, Craig

    2016-11-01

    Schatzkin et al. and other authors demonstrated that the ratios of some conditional statistics such as the true positive fraction are equal to the ratios of unconditional statistics, such as disease detection rates, and therefore we can calculate these ratios between two screening tests on the same population even if negative test patients are not followed with a reference procedure and the true and false negative rates are unknown. We demonstrate that this same property applies to an expected utility metric. We also demonstrate that while simple estimates of relative specificities and relative areas under ROC curves (AUC) do depend on the unknown negative rates, we can write these ratios in terms of disease prevalence, and the dependence of these ratios on a posited prevalence is often weak particularly if that prevalence is small or the performance of the two screening tests is similar. Therefore we can estimate relative specificity or AUC with little loss of accuracy, if we use an approximate value of disease prevalence.

  15. Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis.

    Science.gov (United States)

    An, Jingna; Chen, Qixia; Liu, Qianqian; Rao, Chenli; Li, Dongdong; Wang, Tingting; Tao, Chuanmin; Wang, Lanlan

    2015-07-01

    The resurgence of syphilis in recent years has become a serious threat to public health worldwide, and the serological detection of specific antibodies against Treponema pallidum remains the most reliable method for laboratory diagnosis of syphilis. This study examined the performance of the recently launched HISCL anti-Treponema pallidum (anti-TP) assay as a screening test for syphilis in a high-volume laboratory. The HISCL anti-TP assay was tested in 300 preselected syphilis-positive samples, 704 fresh syphilis-negative samples, 48 preselected potentially interfering samples, and 30 "borderline" samples and was compared head to head with the commercially available Lumipulse G TP-N. In this study, the HISCL anti-TP assay was in perfect agreement with the applied testing algorithms with an overall agreement of 100%, comparable to that of Lumipulse G TP-N (99.63%). The sensitivity and specificity of the HISCL anti-TP assay were 100% (95% confidence interval [CI], 98.42% to 100%) and 100% (95% CI, 99.37% to 100%), respectively. Considering the excellent ease of use and automation, high throughput, and its favorable sensitivity and specificity, the HISCL anti-TP assay may represent a new choice for syphilis screening in high-volume laboratories. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  16. A multicenter family practitioners' research on Chronic Obstructive Pulmonary Disease screening using the COPD Assessment Test.

    Science.gov (United States)

    Demirci, Hakan; Eniste, Koncuy; Basaran, Ebru Onuker; Ocakoglu, Gokhan; Yilmaz, Zeynep; Tuna, Sumeyye

    2017-11-01

    Spirometry is known to be a gold standard for the diagnosis of chronic obstructive pulmonary disease (COPD). COPD Assessment Test (CAT) is an eight-item questionnaire currently in use to evaluate patients with COPD. In the present study, we aimed to evaluate if CAT is an adequate tool for screening COPD. In total, 600 persons aging ⩾40 years old were randomly selected from three different family practice units located in the city center. CAT was asked to the participants and a spirometry was used to assess pulmonary obstruction. Pulmonary obstruction was defined as forced expiratory volume in first second/forced vital capacity (FEV1/FVC)COPD diagnosis was confirmed with the reversibility test. The relationship between CAT results and pulmonary function test values was evaluated. In this sampling, the prevalence of COPD was 4.2%. Reliability of the CAT in the study group was acceptable (Cronbach's α: 0.84). The CAT scores was significantly higher in patients with COPD (PCOPD. CAT is a reliable questionnaire and there is an apparent relationship between the total CAT scores and COPD. However, CAT's ability to screen COPD is limited since it may miss the symptom-free cases.

  17. The Usefulness of {sup 18}F-FDG PET as a Cancer Screening Test

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Doo Heun; Choi, Joon Young; Song, Yun Mi; Lee, Su Jin; Kim, Young Hwan; Lee, Kyung Han; Kim, Byung Tae; Lee, Moon Kyu [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2008-12-15

    The aim of this study was to evaluate the usefulness of whole body positron emission tomography (PET) using {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) for cancer screening in asymptomatic subjects. The subjects were 1,762 men and 259 women who voluntarily underwent {sup 18}F-FDG PET for cancer screening as a part of a routine health examination. Final diagnosis was decided by other diagnostic studies, pathological results or clinical follow-up for 1 year. Of 2,021 subjects, 40 (2.0%) were finally proved to have cancer. Abnormal focal {sup 18}F-FDG uptake suggesting malignancy was found in 102 subjects (5.0%). Among them, 21 subjects (1.0%) were proved to have cancer. Other tests in the routine health examination could not find 9 of 21 cancers (42.9%) detected by PET. The sensitivity, specificity, positive predictive value, and negative predictive value of PET for cancer screening were 52.5%, 95.9%, 20.6%, and 99.0%, respectively. Pathologies of cancers missed on PET were adenocarcinoma (n=9; 3 colon cancers, 3 prostate cancers, 2 stomach cancers, and 1 rectal cancer), differentiated thyroid carcinoma (n=6), bronchioalveolar cell carcinoma (n=2), urinary bladder cancer (n=1), and melanoma (n=1). More than half of cancers which were not detected by PET were smaller than 1 cm in diameter. {sup 18}F-FDG PET might be useful for cancer screening in asymptomatic subjects due to its high specificity and negative predictive value and play a supplementary role to the conventional health check-up, but it could not replace due to limited sensitivity for urological cancers, small-sized tumors and some hypometaboic cancers.

  18. The Usefulness of 18F-FDG PET as a Cancer Screening Test

    International Nuclear Information System (INIS)

    Ko, Doo Heun; Choi, Joon Young; Song, Yun Mi; Lee, Su Jin; Kim, Young Hwan; Lee, Kyung Han; Kim, Byung Tae; Lee, Moon Kyu

    2008-01-01

    The aim of this study was to evaluate the usefulness of whole body positron emission tomography (PET) using 18 F-fluorodeoxyglucose ( 18 F-FDG) for cancer screening in asymptomatic subjects. The subjects were 1,762 men and 259 women who voluntarily underwent 18 F-FDG PET for cancer screening as a part of a routine health examination. Final diagnosis was decided by other diagnostic studies, pathological results or clinical follow-up for 1 year. Of 2,021 subjects, 40 (2.0%) were finally proved to have cancer. Abnormal focal 18 F-FDG uptake suggesting malignancy was found in 102 subjects (5.0%). Among them, 21 subjects (1.0%) were proved to have cancer. Other tests in the routine health examination could not find 9 of 21 cancers (42.9%) detected by PET. The sensitivity, specificity, positive predictive value, and negative predictive value of PET for cancer screening were 52.5%, 95.9%, 20.6%, and 99.0%, respectively. Pathologies of cancers missed on PET were adenocarcinoma (n=9; 3 colon cancers, 3 prostate cancers, 2 stomach cancers, and 1 rectal cancer), differentiated thyroid carcinoma (n=6), bronchioalveolar cell carcinoma (n=2), urinary bladder cancer (n=1), and melanoma (n=1). More than half of cancers which were not detected by PET were smaller than 1 cm in diameter. 18 F-FDG PET might be useful for cancer screening in asymptomatic subjects due to its high specificity and negative predictive value and play a supplementary role to the conventional health check-up, but it could not replace due to limited sensitivity for urological cancers, small-sized tumors and some hypometaboic cancers

  19. Diagnostic accuracy of a two-item Drug Abuse Screening Test (DAST-2).

    Science.gov (United States)

    Tiet, Quyen Q; Leyva, Yani E; Moos, Rudolf H; Smith, Brandy

    2017-11-01

    Drug use is prevalent and costly to society, but individuals with drug use disorders (DUDs) are under-diagnosed and under-treated, particularly in primary care (PC) settings. Drug screening instruments have been developed to identify patients with DUDs and facilitate treatment. The Drug Abuse Screening Test (DAST) is one of the most well-known drug screening instruments. However, similar to many such instruments, it is too long for routine use in busy PC settings. This study developed and validated a briefer and more practical DAST for busy PC settings. We recruited 1300 PC patients in two Department of Veterans Affairs (VA) clinics. Participants responded to a structured diagnostic interview. We randomly selected half of the sample to develop and the other half to validate the new instrument. We employed signal detection techniques to select the best DAST items to identify DUDs (based on the MINI) and negative consequences of drug use (measured by the Inventory of Drug Use Consequences). Performance indicators were calculated. The two-item DAST (DAST-2) was 97% sensitive and 91% specific for DUDs in the development sample and 95% sensitive and 89% specific in the validation sample. It was highly sensitive and specific for DUD and negative consequences of drug use in subgroups of patients, including gender, age, race/ethnicity, marital status, educational level, and posttraumatic stress disorder status. The DAST-2 is an appropriate drug screening instrument for routine use in PC settings in the VA and may be applicable in broader range of PC clinics. Published by Elsevier Ltd.

  20. Validation of the Danish Addenbrooke's Cognitive Examination as a screening test in a memory clinic

    DEFF Research Database (Denmark)

    Stokholm, Jette; Vogel, Asmus; Johannsen, Peter

    2009-01-01

    BACKGROUND: Addenbrooke's Cognitive Examination (ACE) is a cognitive screening test developed to detect dementia. It has been validated in several countries. Validation studies have predominantly included patients with various degrees of dementia and healthy controls. OBJECTIVE: The aim...... (MMSE >or=20), 30 non-demented patients diagnosed with depression (originally referred for evaluation of cognitive symptoms), and 63 healthy volunteers, all between 60 and 85 years of age, were included. All patients were given the ACE as a supplement to the standard diagnostic work-up. RESULTS: The cut...

  1. Sweat conductivity and coulometric quantitative test in neonatal cystic fibrosis screening.

    Science.gov (United States)

    Domingos, Mouseline Torquato; Magdalena, Neiva Isabel Rodrigues; Cat, Mônica Nunes Lima; Watanabe, Alexandra Mitiru; Rosário Filho, Nelson Augusto

    2015-01-01

    To compare the results obtained with the sweat test using the conductivity method and coulometric measurement of sweat chloride in newborns (NBs) with suspected cystic fibrosis (CF) in the neonatal screening program. The sweat test was performed simultaneously by both methods in children with and without CF. The cutoff values to confirm CF were >50 mmol/L in the conductivity and >60 mmol/L in the coulometric test. There were 444 infants without CF (185 males, 234 females, and 24 unreported) submitted to the sweat test through conductivity and coulometric measurement simultaneously, obtaining median results of 32 mmol/L and 12 mmol/L, respectively. For 90 infants with CF, the median values of conductivity and coulometric measurement were 108 mmol/L and 97 mmol/L, respectively. The false positive rate for conductivity was 16.7%, and was higher than 50 mmol/L in all patients with CF, which gives this method a sensitivity of 100% (95% CI: 93.8-97.8), specificity of 96.2% (95% CI: 93.8-97.8), positive predictive value of 83.3% (95% CI: 74.4-91.1), negative predictive value of 100% (95% CI: 90.5-109.4), and 9.8% accuracy. The correlation between the methods was r=0.97 (p>0.001). The best suggested cutoff value was 69.0 mmol/L, with a kappa coefficient=0.89. The conductivity test showed excellent correlation with the quantitative coulometric test, high sensitivity and specificity, and can be used in the diagnosis of CF in children detected through newborn screening. Copyright © 2015 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  2. Screening for Elder Abuse among Turkish Older People: Validity of the Hwalek-Sengstock Elder Abuse Screening Test (H-S "East")

    Science.gov (United States)

    Özmete, Emine; Megahead, Hamido A.

    2017-01-01

    Objective: This study aims to adapt "The Hwalek-Sengstock Elder Abuse Screening Test (H-S "East")" (Neale, Hwalek, Scott, Sengstock, & Stahl, 1991) to Turkish and to assess its validity and reliability while determining the factors that affect elder abuse. Method: The sample of the study is composed of 465 elderly women and…

  3. West Nile virus lineage 2 infection in a blood donor from Vienna, Austria, August 2014.

    Science.gov (United States)

    Jungbauer, C; Hourfar, M K; Stiasny, K; Aberle, S W; Cadar, D; Schmidt-Chanasit, J; Mayr, W R

    2015-03-01

    Eastern Austria is neighbouring regions with ongoing West Nile virus (WNV) transmissions. Three human WNV infections had been diagnosed during the past decade in Austria. The Austrian Red Cross Blood Service (ARC-BS) started a first voluntary screening for WNV in blood donors from Eastern Austria by Nucleic Acid Testing (NAT) in June 2014. This is also the most extensive WNV surveillance programme in humans in Austria so far. In August 2014, one autochthonous WNV infection was detected in a blood donor from Vienna. By now, one in 67,800 whole blood donations was found to be positive for WNV RNA. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Risk Factors for Hepatitis C Virus Infection among Blood Donors in Georgia

    International Nuclear Information System (INIS)

    Zaller, Nickolas; Nelson, Kenrad E.; Aladashvili, Malvina; Badridze, Nino; Rio, Carlos del; Tsertsvadze, Tengiz

    2004-01-01

    Background: Growing awareness about the importance of blood safety for controlling the transmission of hepatitis C virus (HCV) has helped to decrease the spread of this virus in many settings. This study was conducted in order to evaluate potential risk factors for HCV infection among blood donors in Georgia. Methods: The study population consisted of 553 blood donors in three major Georgian cities; Tbilisi, the capital city and Batumi and Poti, naval port cities. Risk factors were examined using a behavior questionnaire. All blood samples were initially tested using 3rd generation anti-HCV enzyme-linked immunosorbent assays and confirmed using recombinant immunoblot assays and nucleic acid testing. Results: Forty-three blood donors, 7.8%, were confirmed HCV positive. Significant risk factors included: drug injection ever (OR: 42; 95% CI: 3.2-550.7); history of hepatitis (OR: 25.9; 95% CI: 4.6-145.5); history of a previous surgical procedure (OR: 148.4; 95% CI: 26.9-817.4); blood transfusion (OR: 25.9; 95% CI: 3.2-210.9). Conclusions: This study found a very high prevalence of HCV among blood donors in Georgia. The main risk factor for HCV infection in this population of blood donors was previous contact with contaminated blood or blood products. Reliable screening of donors and their blood is critical for controlling the further spread of HCV in Georgia

  5. Evaluation of functional color vision requirements and current color vision screening tests for air traffic control specialists.

    Science.gov (United States)

    1990-08-01

    An experiment was conducted to evaluate the relation of type and degree of color vision deficiency and aeromedical color vision screening test scores to performance of color-dependent tasks of Air Traffic Control Specialists. The subjects included 37...

  6. Frequency of HIV type 2 infections among blood donor population from India: A 10-year experience

    Directory of Open Access Journals (Sweden)

    Kannangai R

    2010-01-01

    Full Text Available Purpose: In India, HIV-2 epidemic is alongside with HIV-1. Blood banks are introducing nucleic acid testing (NAT for screening. The limitation of NAT systems is the inability to detect HIV-2. Materials and Method : An analysis of HIV screening of a blood bank at a tertiary care center from 1998 to 2007 was carried out. Results : A total of 175026 donors were screened by serological assays and 789 were reactive for HIV antibody. Only 478 (61% were confirmed positive by Western blot/immunoblot. There were 465 (97.2% donations positive for HIV-1, 6 (1.3% for HIV-2 (monotypic infection and 7 (1.5% for HIV-1 and HIV-2 (dual infection. Conclusion : We show the presence of HIV-2 infection among the blood donors and the need for incorporating HIV-2 detection also in the NAT systems.

  7. Long-term performance of colorectal cancer screening programmes based on the faecal immunochemical test.

    Science.gov (United States)

    Zorzi, Manuel; Hassan, Cesare; Capodaglio, Giulia; Fedato, Chiara; Montaguti, Adriana; Turrin, Anna; Rosano, Alberto; Monetti, Daniele; Stocco, Carmen; Baracco, Susanna; Russo, Francesca; Repici, Alessandro; Rugge, Massimo

    2017-11-03

    The long-term performance of colorectal cancer (CRC) screening programmes based on a 2-year faecal immunochemical test (FIT) is still unclear. In a sample of 50 to 69-year-olds repeatedly screened with the FIT (OC-Hemodia latex agglutination test; cut-off: 20 µg haemoglobin/g faeces), we examined: (1) the FIT positivity rate, the CRC and advanced adenoma detection rate and the FIT's positive predictive value (PPV) for advanced neoplasia, at each round of screening and (2) the cumulative CRC and advanced adenoma detection rate after five rounds of FIT. Over 12 years (2002-2014), 123 347 individuals were administered the FIT up to six times, and 781 CRCs and 4713 advanced adenomas were diagnosed. The CRC and advanced adenoma detection rates declined substantially from the first to the third (rate ratio (RR) 0.25, 95% CI 0.20 to 0.32) and second (RR 0.51, 95% CI 0.47 to 0.56) rounds, respectively, and then remained stable. The PPV for advanced neoplasia dropped by 18% in the second round (RR 0.82, 95% CI 0.77 to 0.89), with no further reduction thereafter due to a concomitant decline in the FIT positivity rate (RR first to sixth rounds: 0.56, 95% CI 0.53 to 0.60).The cumulative CRC and advanced adenoma detection rates over five consecutive rounds were 8.5‰ (95% CI 7.8 to 9.2), and 58.9‰ (95% CI 56.9 to 61.0), respectively. Repeated FIT significantly reduces the burden of colorectal disease while facilitating an efficient use of colonoscopy resources. The cumulative detection rate after five rounds of FIT is similar to primary screening with colonoscopy, supporting the need to account for the cumulative sensitivity of repeated FITs when evaluating the test's efficacy. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Criterion and convergent validity of the Montreal cognitive assessment with screening and standardized neuropsychological testing.

    Science.gov (United States)

    Lam, Benjamin; Middleton, Laura E; Masellis, Mario; Stuss, Donald T; Harry, Robin D; Kiss, Alex; Black, Sandra E

    2013-12-01

    To compare the validity of the Montreal Cognitive Assessment (MoCA) with the criterion standard of standardized neuropsychological testing and to compare the convergent validity of the MoCA with that of existing screening tools and global measures of cognition. Cross-sectional observational study. Tertiary care hospital-based cognitive neurology subspecialty clinic. A convenience sample of 107 individuals with mild Alzheimer's disease (AD, n=75) or mild cognitive impairment (MCI, n=32) from the Sunnybrook Dementia Study. In addition to the MoCA, all participants completed the Mini-Mental State Examination (MMSE), the Mattis Dementia Rating Scale (DRS), and detailed neuropsychological testing. Convergent validity was supported, with MoCA scores correlating well with the MMSE (correlation coefficient (r)=0.66, Pvalidity was supported, with MoCA subscores according to cognitive domain correlating well with analogous neuropsychological tests and, in the case of memory (area under the receiver operating characteristic curve (AUC)=0.86), executive (AUC=0.79), and visuospatial function (AUC=0.79), being reasonably sensitive to impairment in those domains. The MoCA is a valid assessment of cognition that shows good agreement with existing screening tools and global measures (convergent validity) and was superior to the MMSE in this regard. The MoCA domain-specific subscores align with performance on more-detailed neuropsychological tests, suggesting not only good criterion validity for the MoCA, but also that it may be useful in guiding further neuropsychological testing. © 2013, Copyright the Authors Journal compilation © 2013, The American Geriatrics Society.

  9. An evaluation of chemical screening test kits for lead in paint

    Energy Technology Data Exchange (ETDEWEB)

    Oglesby, L.S.

    1996-04-01

    The Residential Lead-Based Paint Hazard Reduction Act (Title X) requires abatement and management of lead-based paint. The purpose of this study was to evaluate three chemical screening test kits using materials and methods from one study and subjecting the results to the statistical analysis of another. The three kits were used to predict the presence of lead in paint at ten weight concentrations from 0.04 to 3.97%. Paint was applied to four wood boards yielding a sample size of 40. Four boards were painted with lead-free paint and used as blanks. All of the boards were tested with the three test kits by an untrained individual having no knowledge of the actual lead content. Sensitivity, specificity, and false positive and negative rates were calculated for the test kit results. The manufactures` detection limits, the observed sensitivity ranged from 1.00 to 0.80, specificity ranged from 1.00 to 0.42, false positive ranged from 0 to 58%, and false negatives ranged from 0 to 20%. At the 0.5% Federal threshold level, the observed sensitivity ranged from 1.00 to 0.94, specificity ranged from 1.00 to 0.5, false positives ranged from 0 to 11.1%, and false negatives ranged from 0 to 20%. The observed false positive and false negative rates for all three kits were found to be significantly lower than those reported in a previous study. These results indicate that the kits perform very well at the Federal threshold, with two of the kits having false negative rates below 12.5% and false positive rates of 3.13%. These results indicate that these two kits would probably be acceptable screening tests for lead in paint.

  10. [Test and programme sensitivities of screening for colorectal cancer in Reggio Emilia].

    Science.gov (United States)

    Campari, Cinzia; Sassatelli, Romano; Paterlini, Luisa; Camellini, Lorenzo; Menozzi, Patrizia; Cattani, Antonella

    2011-01-01

    to estimate the sensitivity of the immunochemical test for faecal occult blood (FOBT) and the sensitivity of the colorectal tumour screening programme in the province of Reggio Emilia. retrospective cohort study, including a sample of 80,357 people of both genders, aged 50-69, who underwent FOBT, during the first round of the screening programme in the province of Reggio Emilia, from April 2005 to December 2007. incidence of interval cancer. The proportional incidence method was used to estimate the sensitivity of FOBT and of the screening programme. Data were stratified according to gender, age and year of interval. the overall sensitivity of FOBT was 73.2% (95%IC 63.8-80.7). The sensitivity of FOBT was lower in females (70.5% vs 75.1%), higher in the 50-59 age group (78.6% vs 70.2%) and higher in the colon than rectum (75.1% vs 68.9%). The test had a significantly higher sensitivity in the 1st year of interval than in the 2nd (84.4% vs 60.5%; RR=0.39, 95%IC 0.22-0.70), a difference which was confirmed, also when data were stratified according to gender. The overall sensitivity of the programme is 70.9% (95%IC 61.5-78.5). No statistically significant differences were shown, if data were stratified according to gender, age or site. Again the sensitivity in the 1st year was significantly higher than in the 2nd year of interval (83.2% vs 57.0%; RR=0.41, 95%IC 0.24-0.69). Overall our data confirmed the findings of similar Italian studies, despite subgroup analysis showed some differences in sensitivity in our study.

  11. Trends in Transfusion Transmitted Infections Among Replacement Blood Donors in Karachi, Pakistan

    Directory of Open Access Journals (Sweden)

    Syed Mohammad Irfan

    2013-06-01

    Full Text Available OBJECTIVE: To determine the prevalence of Hepatitis-B, Hepatitis-C and Human Immunodeficiency infections in replacement blood donors. METHODS: From January 2004 to December 2011, 108,598 apparently healthy donors donated blood at our Blood Bank. Screening was done by Microparticle Enzyme Immuno Assay (MEIA method on Axsym System (Abbott Diagnostic, USA and in year 2011 by Chemiluminescent Immunoassay (CIA method on Architect i2000 (Abbott Diagnostic, USA. From 2010 onward, HIV reactive donors were advised for confirmatory tests and reported back with the results. RESULTS: Of the 108,598 total donors, 108,393 (99.8% were replacement donors with a mean age of 28.92 (17-55 years. Of this, only 164 (0.15% were females. Among the replacement donors, 4,906 (4.5% were found to be reactive for Hepatitis-B, C and Human Immunodeficiency Virus. All the reactive patients, except one, were males. HbsAg was positive in 2,068 (1.90% and anti-HCV in 2832 (2.61% donors, while 111 (0.10% were positive for Human Immunodeficiency Virus. Co-infectivity was observed in 103 (0.09% cases. The prevalence appeared to be higher in younger age group (17-30 yrs. Only 16.6% cases should be patients returned with results of the confirmatory tests for HIV and were found positive. CONCLUSION: Hepatitis-B and C sero-prevalence in our series of replacement donors appears high compared to most studies from neighboring countries and relatively low in comparison to earlier studies from Pakistan. Prevalence of HIV, however, appears low and turn out of HIV positive cases for confirmatory tests is low.

  12. True HIV seroprevalence in Indian blood donors.

    Science.gov (United States)

    Choudhury, N; Ayagiri, A; Ray, V L

    2000-03-01

    The National AIDS Control Organization (NACO), the apex body for controlling AIDS in India, projected that HIV seroprevalence would increase from 7/1000 in 1995 to 21.2/1000 in 1997. A high incidence (8.2%) of HIV was observed in blood donors. This study was carried out to find out the true HIV positivity in Indian blood donors. Blood donors from our centre were followed for more than 5 years to determine the true HIV seroprevalence and our result was compared with similar studies from India. Voluntary and relative blood donors who visited the SGPGIMS, Lucknow, since 1993 to June 1998 were included. They were screened for HIV 1/2 by ELISA kits (WHO approved). First-time HIV-positive samples were preserved frozen for further study (stage-I). They were repeated in duplicate and retested with other kits. If found positive, the sample was labelled as ELISA positive (stage-II). ELISA-positive samples were confirmed by Western Blot (WB) at stage-III. A total of 65 288 donors were included and 834 (12.8/1000) were reactive at stage-I. But 1.1/1000 donors were found to be ELISA positive at stage-II, and 0.28/1000 donors were positive by WB at stage-III. The 'seropositivity' rate from the NACO was significantly (P commercial blood banks. The HIV prevalence of blood donors (and national prevalence) is to be reassessed.

  13. Negotiating boundaries: Accessing donor gametes in India.

    Science.gov (United States)

    Widge, A; Cleland, J

    2011-01-01

    This paper documents how couples and providers access donor materials for conception in the Indian context and perceptions about using them. The objective is to facilitate understanding of critical issues and relevant concerns. A postal survey was conducted with a sample of 6000 gynaecologists and in-depth interviews were -conducted with 39 gynaecologists in four cities. Donor gametes are relatively more acceptable than a few years ago, especially if confidentiality can be -maintained, though lack of availability of donor materials is sometimes an impediment to infertility treatment. Donor sperms are usually accessed from in-house or commercial sperm banks, pathology laboratories, IVF centres, -professional donors, relatives or friends. There is scepticism about screening procedures of sperm banks. Donor eggs are usually accessed from voluntary donors, friends, relatives, egg sharing programmes, donation from other patients, advertising and commercial donors. There are several concerns regarding informed consent for using donated gametes, using -relatives and friends gametes, the unregulated use of gametes and embryos, record keeping and documentation, -unethical and corrupt practices and commercialisation. These issues need to be addressed by patients, providers and regulatory authorities by providing -information, counselling, ensuring informed consent, addressing exploitation and commercialisation, ensuring -monitoring, proper documentation and transparency.

  14. Ropivacaine alters the mechanical properties of hamstring tendons: In vitro controlled mechanical testing of tendons from living donors.

    Science.gov (United States)

    Ollivier, M; Sbihi, J; Sbihi, A; Pithioux, M; Parratte, S; Argenson, J-N

    2017-11-01

    Intraarticular or periarticular injection of ropivacaine (RI) is an element of current knee surgery practices. The goal of this study was to determine the effects of RI on the mechanical properties of hamstring tendons. We hypothesized that RI would have a detrimental effect on the mechanical properties of periarticular soft tissues METHODS: A tensile test to failure was performed on 120 hamstring tendon segments harvested during ACL reconstruction surgery in 120 patients. Two sets of tensile tests were done. The first evaluated the effect of RI itself on the mechanical properties of tendons: 30 samples were soaked for 1hour in a 2% RI solution and compared to 30 samples soaked in a saline solution (control group). The second evaluated the effect of RI concentration on the mechanical properties of hamstring tendons: 30 samples were soaked for 1hour in a 2% RI solution and 30 samples were soaked in a 7.5% RI solution. In the first test, 29 samples from each group were analyzed as two samples (one in each group) failed at the grip interface. The specimens exposed to 2% RI had lower ultimate tensile strength (Δ=4.4MPa, P=0.001), strain energy (Δ=13MPa, P=0.001) and Young's modulus (Δ=1.6MPa, P=0.02) than the specimens in the control group. There was no significant difference in the strain at failure between groups (Δ=5%, P=0.3). In the second test, one specimen from the 7.5% RI group failed during the preloading and was excluded. There was no significant difference in terms of the load at failure and ultimate tensile stress (Δ=0.45MPa, P=0.6) and strain energy (Δ=0.49MPa, P=0.49) between the two groups. There were significant differences in terms of elongation at failure (Δ=28%, P=0.0003) and Young's modulus (Δ=2.6MPa, P=0.005), with the specimens exposed to 7.5% RI undergoing greater deformation and having a lower Young's modulus. While local RI injections are widely performed in clinical practice, the results of this in vitro study point to short

  15. Computer-assisted static/dynamic renal imaging: a screening test for renovascular hypertension

    International Nuclear Information System (INIS)

    Keim, H.J.; Johnson, P.M.; Vaughan, E.D. Jr.; Beg, K.; Follett, D.A.; Freeman, L.M.; Laragh, J.H.

    1979-01-01

    Computer-assisted static/dynamic renal imaging with [ 197 Hg] chlormerodrin and [/sup 99m/Tc] pertechnetate was evaluated prospectively as a screening test for renovascular hypertension. Results are reported for 51 patients: 33 with benign essential hypertension and 18 with renovascular hypertension, and for 21 normal controls. All patients underwent renal arteriography. Patients with significant obesity, renal insufficiency, or renoparenchymal disease were excluded from this study. Independent visual analyses of renal gamma images and time-activity transit curves identified 17 of the 18 patients with renovascular hypertension; one study was equivocal. There were five equivocal and three false-positive results in the essential hypertension and normal control groups. The sensitivity of the method was 94% and the specificity 85%. Since the prevalence of the renovascular subset of hypertension is approximately 5%, the predictive value is only 25%. Inclusion of computer-generated data did not improve this result. Accordingly, this method is not recommended as a primary screening test for renovascular hypertension

  16. Physical examination tests for screening and diagnosis of cervicogenic headache: A systematic review.

    Science.gov (United States)

    Rubio-Ochoa, J; Benítez-Martínez, J; Lluch, E; Santacruz-Zaragozá, S; Gómez-Contreras, P; Cook, C E

    2016-02-01

    It has been suggested that differential diagnosis of headaches should consist of a robust subjective examination and a detailed physical examination of the cervical spine. Cervicogenic headache (CGH) is a form of headache that involves referred pain from the neck. To our knowledge, no studies have summarized the reliability and diagnostic accuracy of physical examination tests for CGH. The aim of this study was to summarize the reliability and diagnostic accuracy of physical examination tests used to diagnose CGH. A systematic review following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines was performed in four electronic databases (MEDLINE, Web of Science, Embase and Scopus). Full text reports concerning physical tests for the diagnosis of CGH which reported the clinometric properties for assessment of CGH, were included and screened for methodological quality. Quality Appraisal for Reliability Studies (QAREL) and Quality Assessment of Studies of Diagnostic Accuracy (QUADAS-2) scores were completed to assess article quality. Eight articles were retrieved for quality assessment and data extraction. Studies investigating diagnostic reliability of physical examination tests for CGH scored poorer on methodological quality (higher risk of bias) than those of diagnostic accuracy. There is sufficient evidence showing high levels of reliability and diagnostic accuracy of the selected physical examination tests for the diagnosis of CGH. The cervical flexion-rotation test (CFRT) exhibited both the highest reliability and the strongest diagnostic accuracy for the diagnosis of CGH. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Screening Utility of the King-Devick Test in Mild Cognitive Impairment and Alzheimer Disease Dementia.

    Science.gov (United States)

    Galetta, Kristin M; Chapman, Kimberly R; Essis, Maritza D; Alosco, Michael L; Gillard, Danielle; Steinberg, Eric; Dixon, Diane; Martin, Brett; Chaisson, Christine E; Kowall, Neil W; Tripodis, Yorghos; Balcer, Laura J; Stern, Robert A

    2017-01-01

    The King-Devick (K-D) test is a 1 to 2 minute, rapid number naming test, often used to assist with detection of concussion, but also has clinical utility in other neurological conditions (eg, Parkinson disease). The K-D involves saccadic eye and other eye movements, and abnormalities thereof may be an early indicator of Alzheimer disease (AD)-associated cognitive impairment. No study has tested the utility of the K-D in AD and we sought to do so. The sample included 206 [135 controls, 39 mild cognitive impairment (MCI), and 32 AD dementia] consecutive subjects from the Boston University Alzheimer's Disease Center registry undergoing their initial annual evaluation between March 2013 and July 2015. The K-D was administered during this period. Areas under the receiver operating characteristic curves generated from logistic regression models revealed the K-D test distinguished controls from subjects with cognitive impairment (MCI and AD dementia) [area under the curve (AUC)=0.72], MCI (AUC=0.71) and AD dementia (AUC=0.74). K-D time scores between 48 and 52 seconds were associated with high sensitivity (>90.0%) and negative predictive values (>85.0%) for each diagnostic group. The K-D correlated strongly with validated attention, processing speed, and visual scanning tests. The K-D test may be a rapid and simple effective screening tool to detect cognitive impairment associated with AD.

  18. [The Amsterdam Dementia Screening Test in cognitively healthy and clinical samples. An update of normative data].

    Science.gov (United States)

    van Toutert, Meta; Diesfeldt, Han; Hoek, Dirk

    2016-10-01

    The six tests in the Amsterdam Dementia Screening Test (ADST) examine the cognitive domains of episodic memory (delayed picture recognition, word learning), orientation, category fluency (animals and occupations), constructional ability (figure copying) and executive function (alternating sequences). New normative data were collected in a sample of 102 elderly volunteers (aged 65-94), including subjects with medical or other health conditions, except dementia or frank cognitive impairment (MMSE > 24). Included subjects were independent in complex instrumental activities of daily living.Fluency, not the other tests, needed adjustment for age and education. A deficit score (0-1) was computed for each test. Summation (range 0-6) proved useful in differentiating patients with dementia (N = 741) from normal elderly (N = 102).Positive and negative predictive power across a range of summed deficit scores and base rates are displayed in Bayesian probability tables.In the normal elderly, delayed recall for eight words was tested and adjusted for initial recall. A recognition test mixed the target words with eight distractors. Delayed recognition was adjusted for immediate and delayed recall.The ADST and the normative data in this paper help the clinical neuropsychologist to make decisions concerning the presence or absence of neurocognitive disorder in individual elderly examinees.

  19. Differences in social representation of blood donation between donors and non-donors: an empirical study.

    Science.gov (United States)

    Guarnaccia, Cinzia; Giannone, Francesca; Falgares, Giorgio; Caligaris, Aldo Ozino; Sales-Wuillemin, Edith

    2015-11-04

    Both donors and non-donors have a positive image of blood donation, so donors and non-donors do not differ regarding their views on donation but do differ in converting their opinion into an active deed of donation. Several studies have identified altruism and empathy as the main factors underlying blood donation. However, a mixture of various motivational factors mould the complex behaviour of donation. This paper presents an exploratory study on differences of social representations of blood donation between blood donors and non-donors, in order to understand the reasons that bring someone to take the decision to become a blood donor. Participants filled in the Adapted Self-Report Altruism Scale, Toronto Empathy Questionnaire and answered a test of verbal association. Descriptive and correlation analyses were carried out on quantitative data, while a prototypic analysis was used for qualitative data. The study was carried out on a convenience sample of 786 individuals, 583 donors (mean age: 35.40 years, SD: 13.01 years; 39.3% female) and 203 non-donors (mean age: 35.10 years, SD: 13.30 years; 67.5% female). Social representations of donors seem to be more complex and articulated than those of non-donors. The terms that appear to be central were more specific in donors (life, needle, blood, help, altruism were the words most associated by non-donors; life, aid, altruism, solidarity, health, love, gift, generosity, voluntary, control, needed, useful, needle were the words most associated by donors). Furthermore, non-donors associated a larger number of terms referring to negative aspects of blood donation. Aspects related to training and the accuracy of any information on blood donation seem to be important in the decision to become a donor and stabilise the behaviour of donation over time, thus ensuring the highest levels of quality and safety in blood establishments.

  20. Cost-Effectiveness of Cervical Cancer Screening With Human Papillomavirus DNA Testing and HPV-16,18 Vaccination

    Science.gov (United States)

    Goldhaber-Fiebert, Jeremy D.; Stout, Natasha K.; Salomon, Joshua A.; Kuntz, Karen M.; Goldie, Sue J.

    2011-01-01

    Background The availability of human papillomavirus (HPV) DNA testing and vaccination against HPV types 16 and 18 (HPV-16,18) motivates questions about the cost-effectiveness of cervical cancer prevention in the United States for unvaccinated older women and for girls eligible for vaccination. Methods An empirically calibrated model was used to assess the quality-adjusted life years (QALYs), lifetime costs, and incremental cost-effectiveness ratios (2004 US dollars per QALY) of screening, vaccination of preadolescent girls, and vaccination combined with screening. Screening varied by initiation age (18, 21, or 25 years), interval (every 1, 2, 3, or 5 years), and test (HPV DNA testing of cervical specimens or cytologic evaluation of cervical cells with a Pap test). Testing strategies included: 1) cytology followed by HPV DNA testing for equivocal cytologic results (cytology with HPV test triage); 2) HPV DNA testing followed by cytology for positive HPV DNA results (HPV test with cytology triage); and 3) combined HPV DNA testing and cytology. Strategies were permitted to switch once at age 25, 30, or 35 years. Results For unvaccinated women, triennial cytology with HPV test triage, beginning by age 21 years and switching to HPV testing with cytology triage at age 30 years, cost $78 000 per QALY compared with the next best strategy. For girls vaccinated before age 12 years, this same strategy, beginning at age 25 years and switching at age 35 years, cost $41 000 per QALY with screening every 5 years and $188 000 per QALY screening triennially, each compared with the next best strategy. These strategies were more effective and cost-effective than screening women of all ages with cytology alone or cytology with HPV triage annually or biennially. Conclusions For both vaccinated and unvaccinated women, age-based screening by use of HPV DNA testing as a triage test for equivocal results in younger women and as a primary screening test in older women is expected to be more

  1. A first approach to a neuropsychological screening tool using eye-tracking for bedside cognitive testing based on the Edinburgh Cognitive and Behavioural ALS Screen.

    Science.gov (United States)

    Keller, Jürgen; Krimly, Amon; Bauer, Lisa; Schulenburg, Sarah; Böhm, Sarah; Aho-Özhan, Helena E A; Uttner, Ingo; Gorges, Martin; Kassubek, Jan; Pinkhardt, Elmar H; Abrahams, Sharon; Ludolph, Albert C; Lulé, Dorothée

    2017-08-01

    Reliable assessment of cognitive functions is a challenging task in amyotrophic lateral sclerosis (ALS) patients unable to speak and write. We therefore present an eye-tracking based neuropsychological screening tool based on the Edinburgh Cognitive and Behavioural ALS Screen (ECAS), a standard screening tool for cognitive deficits in ALS. In total, 46 ALS patients and 50 healthy controls matched for age, gender and education were tested with an oculomotor based and a standard paper-and-pencil version of the ECAS. Significant correlation between both versions was observed for ALS patients and healthy controls in the ECAS total score and in all of its ALS-specific domains (all r > 0.3; all p ALS patients and healthy controls in the ECAS total score (p ALS patients who are unable to speak or write.

  2. Imunoblot como teste suplementar para detecção de anticorpos contra o vírus da hepatite C em doadores de sangue Immunoblot as a supplemental test to detect antibodies to hepatitis C virus in blood donors

    Directory of Open Access Journals (Sweden)

    Francisco José Dutra Souto

    2002-02-01

    Full Text Available Testes suplementares para melhorar a especificidade do anti-VHC por ELISA nos bancos de sangue não são oficialmente recomendados no Brasil. No intuito de avaliar a taxa de falso-positivos, 70 doadores com transaminases normais e anti-VHC por ELISA foram submetidos a imunoblot de 3ª geração no Hemocentro de Mato Grosso, que não dispõe da técnica da reação de cadeia de polimerase. O teste confirmou o anti-VHC em 44 (62,9%, sendo negativo em 22 (31,4% e indeterminado em 4 (5,7%. Confirmação pelo imunoblot ajuda a identificar os testes ELISA que são falso-positivos, tranqüilizando o grande contingente de doadores nessa situação e separando os que necessitam de acompanhamento médico. Com esse objetivo, sugere-se que o imunoblot poderia ser útil nos bancos de sangue brasileiros que não contam com técnicas de Biologia Molecular.Supplemental tests using Immunoblot are recommended to improve specificity of anti-HCV by ELISA. In Brazil immunoblot is not officially recommended. Aiming to identify EIA false-positive rate 70 positive EIA anti-HCV blood donors were submitted to 3rd generation immunoblot at Hemocentro of Mato Grosso State where polymerase chain reaction tests are not performed. There were 44 (62.9% immunoblot-positive, 22 (31.4% negative and 4 (5.7% indeterminate. Anti-HCV immunoblot can distinguish blood donors with false-positive ELISA from those who need medical assessment. Our data suggest that immunoblot could be useful in Brazilian blood banks where molecular biology tests are not available.

  3. Attitudes of pregnant women and male partners towards non-invasive prenatal testing and widening the scope of prenatal screening

    NARCIS (Netherlands)

    van Schendel, Rachèl V.; Kleinveld, Johanna H.; Dondorp, Wybo J.; Pajkrt, Eva; Timmermans, Danielle R. M.; Holtkamp, Kim C. A.; Karsten, Margreet; Vlietstra, Anne L.; Lachmeijer, Augusta M. A.; Henneman, Lidewij

    2014-01-01

    Non-invasive prenatal testing (NIPT) and its potential to test for multiple disorders has received much attention. This study explores attitudes of women and men towards NIPT, and their views on widening the scope of prenatal testing in a country with a low uptake of prenatal screening (The

  4. Clinical evaluation of the Nanoduct sweat test system in the diagnosis of cystic fibrosis after newborn screening

    NARCIS (Netherlands)

    Vernooij-van Langen, Annette; Dompeling, Edward; Yntema, Jan-Bart; Arets, HGM; Tiddens, Harm; Loeber, Gerard; Dankert-Roelse, Jeannette

    After a positive newborn screening test for cystic fibrosis (CF), a sweat test is performed to confirm the diagnosis. The success rate of the generally acknowledged methods (Macroduct/Gibson and Cooke) in newborns varies between 73 and 99 %. The Nanoduct sweat test system is easier to perform and

  5. Combinations of two odorants of smell identification test for screening of olfactory impairment.

    Science.gov (United States)

    Shiga, Hideaki; Yamamoto, Junpei; Kitamura, Miwa; Nakagawa, Hideaki; Matsubasa, Tomoko; Seo, Atsuko; Miwa, Takaki

    2014-12-01

    To determine whether combinations of two odorants of the Open Essence smell identification test can be used to screen for olfactory impairment in Japanese people. A total of 243 Japanese subjects (142 males, 101 females; mean age, 37.5 years; age range, 20-62 years) were enrolled in the study. The main outcome measures were the results of olfactory testing by using the full 12 odorants (condensed milk, cooking gas, curry, cypress wood (Japanese cypress, hinoki), India ink, Japanese orange (mikan), menthol, perfume, roasted garlic, rose, sweaty-smelling clothes, and wood) of the Open Essence test as well as combinations of two odorants of the Open Essence test, and the results of self-reported questionnaires addressing awareness of a smell disorder, history of sinunasal disease, self-reported nasal obstruction, and history of smoking. In screening with combinations of two odorants, the highest positive likelihood ratio (19.1) was obtained with the cypress wood and India ink odorants. All subjects correctly identified the curry odorant. Combinations of other odorants also had high positive likelihood ratios (India ink and sweaty-smelling clothes, 17.6; perfume and sweaty-smelling clothes, 14.7; cypress wood and roasted garlic, 14.1; cypress wood and rose, 13.2; cypress wood and perfume, 11.0; cypress wood and wood, 10.7). The combination of cypress wood and India ink odorants may be useful for detecting individuals with olfactory impairment among subjects who can correctly identify the curry odorant. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. A rapid and simple screening test to detect the radiation treatment of fat-containing foods

    International Nuclear Information System (INIS)

    Delincee, H.

    1993-01-01

    In recent years several international efforts have been made to develop analytical detection methods for the radiation treatment of foods. A number of methods has indeed been developed. Particularly, for fat-containing foods several methods are already in an advanced stage. In addition to the sophisticated techniques such as gas chromatography/mass spectrometry which require relatively expensive equipment and/or extended sample preparation time, it would be desirable to have quick and simple screening tests, which immediately on-the-spot give some indication whether a food product has been irradiated or not. A solution to this problem for lipid-containing foods has been put forward by Furuta and co-workers (1991, 1992), who estimated the amount of carbon monoxide originating from the lipid fraction in poultry meat after irradiation. The carbon monoxide was expelled from the frozen meat by quick microwave heating and in the head space of the sample, the formed carbon monoxide was determined by gas chromatography. In order to speed up time of analysis, we have used an electrochemical CO sensor, as also is being used to estimate CO in ambient air in workplaces, to determine the CO content in the vapor expelled from the irradiated samples. This CO test is very simple, cheap and easy to perform. It takes only a few minutes to screen food samples for evidence of their having been radiation processed. If doubts concerning the radiation treatment of a sample arise, the more sophisticated - and expensive -methods for analyzing lipid-containing foods can be applied. Certainly the test is limited to food products which contain a certain amount of fat. A preliminary test with lean shrimps showed practically no difference between irradiated (2.5 and 5 kGy) and non-irradiated samples. By relating CO production to the fat content, possibly a better parameter for classification can be obtained. (orig./vhe)

  7. Fecal occult blood test for colorectal cancer screening: an evidence-based analysis.

    Science.gov (United States)

    2009-01-01

    The colorectal cancer (CRC) screening project was undertaken by the Medical Advisory Secretariat (MAS) in collaboration with the Cancer Care Ontario (CCO).In November 2007, the Ontario Health Technology Advisory Committee (OHTAC) MAS to conduct an evidence-based analysis of the available data with respect to colorectal cancer diagnosis and prevention. The general purpose of the project was to investigate the effectiveness, cost effectiveness, and safety of the various methods and techniques used for colorectal cancer screening in average risk people, 50 years of age and older.The options currently offered for colorectal cancer screening were reviewed and five technologies were selected for review:Computed tomographic (CT) colonographyMagnetic resonance (MR) colonographyWireless capsule endoscopy (PillCam Colon)Fecal occult blood test (FOBT)Flexible sigmoidoscopyIn this review, colonoscopy was considered as the "gold standard" technique by which the effectiveness of all other modalities could be evaluated. An economic analysis was also conducted to determine cost-effectiveness of different