WorldWideScience

Sample records for donor scoring system

  1. Identification of the optimal donor quality scoring system and measure of early renal function in kidney transplantation.

    LENUS (Irish Health Repository)

    Moore, Jason

    2009-02-27

    The early identification of kidney allografts at risk of later dysfunction has implications for clinical practice. Donor quality scoring systems (preoperative) and measures of early allograft function (first week postoperative) have previously shown practical utility. This study aimed to determine the optimal parameter(s) (preoperative and postoperative) with greatest predictive power for the development of subsequent allograft dysfunction.

  2. Systems of donor transfer

    NARCIS (Netherlands)

    F.T. de Charro (Frank); J.E.M. Akveld (Hans); E. Hessing (Ellen)

    1993-01-01

    textabstractThe development of medical knowledge has resulted in a demand in society for donor organs, but the recruitment of donor organs for transplantation is difficult. This paper aims to provide some general insights into the complex interaction processes involved. A laissez-faire policy, in

  3. Volleyball Scoring Systems.

    Science.gov (United States)

    Calhoun, William; Dargahi-Noubary, G. R.; Shi, Yixun

    2002-01-01

    The widespread interest in sports in our culture provides an excellent opportunity to catch students' attention in mathematics and statistics classes. One mathematically interesting aspect of volleyball, which can be used to motivate students, is the scoring system. (MM)

  4. Impact of predictive scoring model and e-mail messages on African American blood donors.

    Science.gov (United States)

    Bachegowda, Lohith S; Timm, Brad; Dasgupta, Pinaki; Hillyer, Christopher D; Kessler, Debra; Rebosa, Mark; France, Christopher R; Shaz, Beth H

    2017-06-01

    Expanding the African American (AA) donor pool is critical to sustain transfusion support for sickle cell disease patients. The aims were to: 1) apply cognitive computing on donation related metrics to develop a predictive model that effectively identifies repeat AA donors, 2) determine whether a single e-mail communication could improve AA donor retention and compare retention results on higher versus lower predictive score donors, and 3) evaluate the effect of e-mail marketing on AA donor retention with culturally versus nonculturally tailored message. Between 2011 and 2012, 30,786 AA donors donated blood at least once on whom predictive repeat donor scores (PRDSs) was generated from donor-related metrics (frequency of donations, duration between donations, age, blood type, and sex). In 2013, 28% (8657/30,786) of 2011 to 2012 donors returned to donate on whom PRDS was validated. Returning blood donors had a higher mean PRDS compared to nonreturning donors (0.649 vs. 0.268; p e-mail pilot, high PRDS (≥0.6) compared to low PRDS (e-mail opening rate (p e-mail, 159% higher presentation rate (p e-mail communication has the potential to increase the efficiency of donor marketing. © 2017 AABB.

  5. A histopathological score on baseline biopsies from elderly donors predicts outcome 1 year after renal transplantation

    DEFF Research Database (Denmark)

    Toft, Birgitte G; Federspiel, Birgitte H; Sørensen, Søren S

    2012-01-01

    wall thickness of arteries and/or arterioles. Nineteen renal baseline biopsies from 15 donors (age: 64 ± 10 years) were included and following consensus the histopathological score was 4.3 ± 2.1 (intraclass correlation coefficient: 0.81; confidence interval: 0.66-0.92). The donor organs were used......Kidneys from elderly deceased patients and otherwise marginal donors may be considered for transplantation and a pretransplantation histopathological score for prediction of postoperative outcome is warranted. In a retrospective design, 29 baseline renal needle biopsies from elderly deceased donors...... Danish donors a histopathological score on baseline renal needle biopsies, with at least ten glomeruli and one artery present, predicts graft function 1 year after transplantation....

  6. South African Scoring System

    African Journals Online (AJOL)

    2014-11-18

    Nov 18, 2014 ... for 80% (SASS score) and 75% (NOT) of the variation in the regression model. Consequently, SASS ... further investigation: spatial analyses of macroinvertebrate assemblages; and the use of structural and functional metrics. Keywords: .... conductivity levels was assessed using multiple linear regres- sion.

  7. Skin scoring in systemic sclerosis

    DEFF Research Database (Denmark)

    Zachariae, Hugh; Bjerring, Peter; Halkier-Sørensen, Lars

    1994-01-01

    Forty-one patients with systemic sclerosis were investigated with a new and simple skin score method measuring the degree of thickening and pliability in seven regions together with area involvement in each region. The highest values were, as expected, found in diffuse cutaneous systemic sclerosis...... (type III SS) and the lowest in limited cutaneous systemic sclerosis (type I SS) with no lesions extending above wrists and ancles. A positive correlation was found to the aminoterminal propeptide of type III procollagen, a serological marker for synthesis of type III collagen. The skin score...

  8. Scoring System Improvements to Three Leadership Predictors

    National Research Council Canada - National Science Library

    Dela

    1997-01-01

    .... The modified scoring systems were evaluated by rescoring responses randomly selected from the sample which had been scored according to the scoring systems originally developed for the leadership research...

  9. Dual Kidney Allocation Score: A Novel Algorithm Utilizing Expanded Donor Criteria for the Allocation of Dual Kidneys in Adults.

    Science.gov (United States)

    Johnson, Adam P; Price, Thea P; Lieby, Benjamin; Doria, Cataldo

    2016-09-08

    BACKGROUND Dual kidney transplantation (DKT) of expanded-criteria donors is a cost-intensive procedure that aims to increase the pool of available deceased organ donors and has demonstrated equivalent outcomes to expanded-criteria single kidney transplantation (eSKT). The objective of this study was to develop an allocation score based on predicted graft survival from historical dual and single kidney donors. MATERIAL AND METHODS We analyzed United Network for Organ Sharing (UNOS) data for 1547 DKT and 26 381 eSKT performed between January 1994 and September 2013. We utilized multivariable Cox regression to identify variables independently associated with graft survival in dual and single kidney transplantations. We then derived a weighted multivariable product score from calculated hazard ratios to model the benefit of transplantation as dual kidneys. RESULTS Of 36 donor variables known at the time of listing, 13 were significantly associated with graft survival. The derived dual allocation score demonstrated good internal validity with strong correlation to improved survival in dual kidney transplants. Donors with scores less than 2.1 transplanted as dual kidneys had a worsened median survival of 594 days (24%, p-value 0.031) and donors with scores greater than 3.9 had improved median survival of 1107 days (71%, p-value 0.002). There were 17 733 eSKT (67%) and 1051 DKT (67%) with scores in between these values and no differences in survival (p-values 0.676 and 0.185). CONCLUSIONS We have derived a dual kidney allocation score (DKAS) with good internal validity. Future prospective studies will be required to demonstrate external validity, but this score may help to standardize organ allocation for dual kidney transplantation.

  10. Interval Coded Scoring: a toolbox for interpretable scoring systems

    Directory of Open Access Journals (Sweden)

    Lieven Billiet

    2018-04-01

    Full Text Available Over the last decades, clinical decision support systems have been gaining importance. They help clinicians to make effective use of the overload of available information to obtain correct diagnoses and appropriate treatments. However, their power often comes at the cost of a black box model which cannot be interpreted easily. This interpretability is of paramount importance in a medical setting with regard to trust and (legal responsibility. In contrast, existing medical scoring systems are easy to understand and use, but they are often a simplified rule-of-thumb summary of previous medical experience rather than a well-founded system based on available data. Interval Coded Scoring (ICS connects these two approaches, exploiting the power of sparse optimization to derive scoring systems from training data. The presented toolbox interface makes this theory easily applicable to both small and large datasets. It contains two possible problem formulations based on linear programming or elastic net. Both allow to construct a model for a binary classification problem and establish risk profiles that can be used for future diagnosis. All of this requires only a few lines of code. ICS differs from standard machine learning through its model consisting of interpretable main effects and interactions. Furthermore, insertion of expert knowledge is possible because the training can be semi-automatic. This allows end users to make a trade-off between complexity and performance based on cross-validation results and expert knowledge. Additionally, the toolbox offers an accessible way to assess classification performance via accuracy and the ROC curve, whereas the calibration of the risk profile can be evaluated via a calibration curve. Finally, the colour-coded model visualization has particular appeal if one wants to apply ICS manually on new observations, as well as for validation by experts in the specific application domains. The validity and applicability

  11. THE EFFICIENCY OF TENNIS DOUBLES SCORING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Geoff Pollard

    2010-09-01

    Full Text Available In this paper a family of scoring systems for tennis doubles for testing the hypothesis that pair A is better than pair B versus the alternative hypothesis that pair B is better than A, is established. This family or benchmark of scoring systems can be used as a benchmark against which the efficiency of any doubles scoring system can be assessed. Thus, the formula for the efficiency of any doubles scoring system is derived. As in tennis singles, one scoring system based on the play-the-loser structure is shown to be more efficient than the benchmark systems. An expression for the relative efficiency of two doubles scoring systems is derived. Thus, the relative efficiency of the various scoring systems presently used in doubles can be assessed. The methods of this paper can be extended to a match between two teams of 2, 4, 8, …doubles pairs, so that it is possible to establish a measure for the relative efficiency of the various systems used for tennis contests between teams of players.

  12. A diagnostic scoring system for myxedema coma.

    Science.gov (United States)

    Popoveniuc, Geanina; Chandra, Tanu; Sud, Anchal; Sharma, Meeta; Blackman, Marc R; Burman, Kenneth D; Mete, Mihriye; Desale, Sameer; Wartofsky, Leonard

    2014-08-01

    To develop diagnostic criteria for myxedema coma (MC), a decompensated state of extreme hypothyroidism with a high mortality rate if untreated, in order to facilitate its early recognition and treatment. The frequencies of characteristics associated with MC were assessed retrospectively in patients from our institutions in order to derive a semiquantitative diagnostic point scale that was further applied on selected patients whose data were retrieved from the literature. Logistic regression analysis was used to test the predictive power of the score. Receiver operating characteristic (ROC) curve analysis was performed to test the discriminative power of the score. Of the 21 patients examined, 7 were reclassified as not having MC (non-MC), and they were used as controls. The scoring system included a composite of alterations of thermoregulatory, central nervous, cardiovascular, gastrointestinal, and metabolic systems, and presence or absence of a precipitating event. All 14 of our MC patients had a score of ≥60, whereas 6 of 7 non-MC patients had scores of 25 to 50. A total of 16 of 22 MC patients whose data were retrieved from the literature had a score ≥60, and 6 of 22 of these patients scored between 45 and 55. The odds ratio per each score unit increase as a continuum was 1.09 (95% confidence interval [CI], 1.01 to 1.16; P = .019); a score of 60 identified coma, with an odds ratio of 1.22. The area under the ROC curve was 0.88 (95% CI, 0.65 to 1.00), and the score of 60 had 100% sensitivity and 85.71% specificity. A score ≥60 in the proposed scoring system is potentially diagnostic for MC, whereas scores between 45 and 59 could classify patients at risk for MC.

  13. Ten years cardiovascular risk estimation according to Framingham score and non HDL-cholesterol in blood donors.

    Science.gov (United States)

    Graffigna, Mabel Nora; Berg, Gabriela; Migliano, Marta; Salgado, Pablo; Soutelo, Jimena; Musso, Carla

    2015-01-01

    Cardiovascular disease (CVD) is currently the primary cause of morbidity and mortality. (1) Assess the 10 years risk for CVD in Argentinean blood donors, according to Framingham score (updated by ATP III), (2) evaluate the prevalence of the MS, (3) evaluate non HDL-cholesterol level in this population as other risk for CVD. A prospective, epidemiological, transversal study was performed to evaluate 585 volunteer blood donors for two years. Non HDL-C was calculated as total cholesterol minus HDL-C and we evaluated the 10 years risk for CVD according to Framingham score (updated by ATP III). Metabolic syndrome prevalence was estimated according to ATP III and IDF criteria. Non HDL-C was (media±SD) 178.3±48.0 mg/dl in participants with MS and 143.7±39.3 mg/dl without MS (ATPIII) and 160.1±43.6 mg/dl in participants with MS and 139.8±43.1 mg/dl without MS (IDF). Participants with MS presented an OR of 3.1; IC 95% (2-5) of CVD according to de Framingham score. Individuals with MS and elevated non HDL-C are at a higher estimated risk for cardiovascular events in the next 10 years according to the Framingham risk score. Copyright © 2014. Published by Elsevier Ltd.

  14. Long-term results after lung transplantation using organs from circulatory death donors: a propensity score-matched analysis†.

    Science.gov (United States)

    Sabashnikov, Anton; Patil, Nikhil P; Popov, Aron-Frederik; Soresi, Simona; Zych, Bartlomiej; Weymann, Alexander; Mohite, Prashant N; García Sáez, Diana; Zeriouh, Mohamed; Wahlers, Thorsten; Choi, Yeong-Hoon; Wippermann, Jens; Wittwer, Thorsten; De Robertis, Fabio; Bahrami, Toufan; Amrani, Mohamed; Simon, André R

    2016-01-01

    Due to organ shortage in lung transplantation (LTx), donation after circulatory death (DCD) has been implemented in several countries, contributing to an increasing number of organs transplanted. We sought to assess long-term outcomes after LTx with organs procured following circulatory death in comparison with those obtained from donors after brain death (DBD). Between January 2007 and November 2013, 302 LTxs were performed in our institution, whereby 60 (19.9%) organs were retrieved from DCD donors. We performed propensity score matching (DCD:DBD = 1:2) based on preoperative donor and recipient factors that were significantly different in univariate analysis. After propensity matching, there were no statistically significant differences between the groups in terms of demographics and preoperative donor and recipient characteristics. There were no significant differences regarding intraoperative variables and total ischaemic time. Patients from the DCD group had significantly higher incidence of primary graft dysfunction grade 3 at the end of the procedure (P = 0.014), and significantly lower pO2/FiO2 ratio during the first 24 h after the procedure (P = 0.018). There was a trend towards higher incidence of the need for postoperative extracorporeal life support in the DCD group. Other postoperative characteristics were comparable. While the overall cumulative survival was not significantly different, the DCD group had significantly poorer results in terms of bronchiolitis obliterans syndrome (BOS)-free survival in the long-term follow-up. Long-term results after LTx with organs procured following DCD are in general comparable with those obtained after DBD LTx. However, patients transplanted using organs from DCD donors have a predisposition for development of BOS in the longer follow-up. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Wearable PPG sensor based alertness scoring system.

    Science.gov (United States)

    Dey, Jishnu; Bhowmik, Tanmoy; Sahoo, Saswata; Tiwari, Vijay Narayan

    2017-07-01

    Quantifying mental alertness in today's world is important as it enables the person to adopt lifestyle changes for better work efficiency. Miniaturized sensors in wearable devices have facilitated detection/monitoring of mental alertness. Photoplethysmography (PPG) sensors through Heart Rate Variability (HRV) offer one such opportunity by providing information about one's daily alertness levels without requiring any manual interference from the user. In this paper, a smartwatch based alertness estimation system is proposed. Data collected from PPG sensor of smartwatch is processed and fed to machine learning based model to get a continuous alertness score. Utility functions are designed based on statistical analysis to give a quality score on different stages of alertness such as awake, long sleep and short duration power nap. An intelligent data collection approach is proposed in collaboration with the motion sensor in the smartwatch to reduce battery drainage. Overall, our proposed wearable based system provides a detailed analysis of alertness over a period in a systematic and optimized manner. We were able to achieve an accuracy of 80.1% for sleep/awake classification along with alertness score. This opens up the possibility for quantifying alertness levels using a single PPG sensor for better management of health related activities including sleep.

  16. A Comparison of Two Scoring Methods for an Automated Speech Scoring System

    Science.gov (United States)

    Xi, Xiaoming; Higgins, Derrick; Zechner, Klaus; Williamson, David

    2012-01-01

    This paper compares two alternative scoring methods--multiple regression and classification trees--for an automated speech scoring system used in a practice environment. The two methods were evaluated on two criteria: construct representation and empirical performance in predicting human scores. The empirical performance of the two scoring models…

  17. Evaluation of modified Alvarado scoring system and RIPASA scoring system as diagnostic tools of acute appendicitis.

    Science.gov (United States)

    Shuaib, Abdullah; Shuaib, Ali; Fakhra, Zainab; Marafi, Bader; Alsharaf, Khalid; Behbehani, Abdullah

    2017-01-01

    Acute appendicitis is the most common surgical condition presented in emergency departments worldwide. Clinical scoring systems, such as the Alvarado and modified Alvarado scoring systems, were developed with the goal of reducing the negative appendectomy rate to 5%-10%. The Raja Isteri Pengiran Anak Saleha Appendicitis (RIPASA) scoring system was established in 2008 specifically for Asian populations. The aim of this study was to compare the modified Alvarado with the RIPASA scoring system in Kuwait population. This study included 180 patients who underwent appendectomies and were documented as having "acute appendicitis" or "abdominal pain" in the operating theatre logbook (unit B) from November 2014 to March 2016. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), diagnostic accuracy, predicted negative appendectomy and receiver operating characteristic (ROC) curve of the modified Alvarado and RIPASA scoring systems were derived using SPSS statistical software. A total of 136 patients were included in this study according to our criteria. The cut-off threshold point of the modified Alvarado score was set at 7.0, which yielded a sensitivity of 82.8% and a specificity of 56%. The PPV was 89.3% and the NPV was 42.4%. The cut-off threshold point of the RIPASA score was set at 7.5, which yielded a 94.5% sensitivity and an 88% specificity. The PPV was 97.2% and the NPV was 78.5%. The predicted negative appendectomy rates were 10.7% and 2.2% for the modified Alvarado and RIPASA scoring systems, respectively. The negative appendectomy rate decreased significantly, from 18.4% to 10.7% for the modified Alvarado, and to 2.2% for the RIPASA scoring system, which was a significant difference (PAsian populations. It consists of 14 clinical parameters that can be obtained from a good patient history, clinical examination and laboratory investigations. The RIPASA scoring system is more accurate and specific than the modified Alvarado

  18. Clinical Risk Scoring Models for Prediction of Acute Kidney Injury after Living Donor Liver Transplantation: A Retrospective Observational Study.

    Directory of Open Access Journals (Sweden)

    Mi Hye Park

    Full Text Available Acute kidney injury (AKI is a frequent complication of liver transplantation and is associated with increased mortality. We identified the incidence and modifiable risk factors for AKI after living-donor liver transplantation (LDLT and constructed risk scoring models for AKI prediction. We retrospectively reviewed 538 cases of LDLT. Multivariate logistic regression analysis was used to evaluate risk factors for the prediction of AKI as defined by the RIFLE criteria (RIFLE = risk, injury, failure, loss, end stage. Three risk scoring models were developed in the retrospective cohort by including all variables that were significant in univariate analysis, or variables that were significant in multivariate analysis by backward or forward stepwise variable selection. The risk models were validated by way of cross-validation. The incidence of AKI was 27.3% (147/538 and 6.3% (34/538 required postoperative renal replacement therapy. Independent risk factors for AKI by multivariate analysis of forward stepwise variable selection included: body-mass index >27.5 kg/m2 [odds ratio (OR 2.46, 95% confidence interval (CI 1.32-4.55], serum albumin 20 (OR 2.01, 95%CI 1.17-3.44, operation time >600 min (OR 1.81, 95%CI 1.07-3.06, warm ischemic time >40 min (OR 2.61, 95%CI 1.55-4.38, postreperfusion syndrome (OR 2.96, 95%CI 1.55-4.38, mean blood glucose during the day of surgery >150 mg/dl (OR 1.66, 95%CI 1.01-2.70, cryoprecipitate > 6 units (OR 4.96, 95%CI 2.84-8.64, blood loss/body weight >60 ml/kg (OR 4.05, 95%CI 2.28-7.21, and calcineurin inhibitor use without combined mycophenolate mofetil (OR 1.87, 95%CI 1.14-3.06. Our risk models performed better than did a previously reported score by Utsumi et al. in our study cohort. Doses of calcineurin inhibitor should be reduced by combined use of mycophenolate mofetil to decrease postoperative AKI. Prospective randomized trials are required to address whether artificial modification of hypoalbuminemia, hyperglycemia

  19. Comparable Short- and Long-term Outcomes in Living Donor and Deceased Donor Liver Transplantations for Patients With Model for End-stage Liver Disease Scores ≥35 in a Hepatitis-B Endemic Area.

    Science.gov (United States)

    Chok, Kenneth S H; Fung, James Y Y; Chan, Albert C Y; Dai, Wing Chiu; Sharr, William W; Cheung, Tan To; Chan, See Ching; Lo, Chung Mau

    2017-01-01

    To evaluate if living donor liver transplantation (LDLT) should be offered to patients with Model for End-stage Liver Disease (MELD) scores ≥35. No data was available to support LDLT of such patients. Data of 672 consecutive adult liver transplant recipients from 2005 to 2014 at our center were reviewed. Patients with MELD scores ≥35 were divided into the deceased donor liver transplantation (DDLT) group and the LDLT group and were compared. Univariate analysis was performed to identify risk factors affecting survival. The LDLT group (n = 54) had younger (33 yrs vs 50 yrs, P standard-liver-volume rates (51.28% vs 99.76%, P Hong Kong, where most waitlisted patients have acute-on-chronic liver failure from hepatitis B, LDLT is a wise alternative to DDLT.

  20. Ultrafast Photoinduced Electron Transfer in Bimolecular Donor-Acceptor Systems

    KAUST Repository

    Alsulami, Qana A.

    2016-11-30

    The efficiency of photoconversion systems, such as organic photovoltaic (OPV) cells, is largely controlled by a series of fundamental photophysical processes occurring at the interface before carrier collection. A profound understanding of ultrafast interfacial charge transfer (CT), charge separation (CS), and charge recombination (CR) is the key determinant to improving the overall performances of photovoltaic devices. The discussion in this dissertation primarily focuses on the relevant parameters that are involved in photon absorption, exciton separation, carrier transport, carrier recombination and carrier collection in organic photovoltaic devices. A combination of steady-state and femtosecond broadband transient spectroscopies was used to investigate the photoinduced charge carrier dynamics in various donor-acceptor systems. Furthermore, this study was extended to investigate some important factors that influence charge transfer in donor-acceptor systems, such as the morphology, energy band alignment, electronic properties and chemical structure. Interestingly, clear correlations among the steady-state measurements, time-resolved spectroscopy results, grain alignment of the electron transporting layer (ETL), carrier mobility, and device performance are found. In this thesis, we explored the significant impacts of ultrafast charge separation and charge recombination at donor/acceptor (D/A) interfaces on the performance of a conjugated polymer PTB7-Th device with three fullerene acceptors: PC71BM, PC61BM and IC60BA. Time-resolved laser spectroscopy and high-resolution electron microscopy can illustrate the basis for fabricating solar cell devices with improved performances. In addition, we studied the effects of the incorporation of heavy metals into π-conjugated chromophores on electron transfer by monitoring the triplet state lifetime of the oligomer using transient absorption spectroscopy, as understanding the mechanisms controlling intersystem crossing and

  1. Modifying scoring system at South African University rugby level ...

    African Journals Online (AJOL)

    Success in rugby is measured by winning the game and in order to do so, teams need to score more points ... if modifying the scoring system at South African University rugby level changes the game dynamics. ... AJOL African Journals Online.

  2. Evaluation of a Lameness Scoring System for Dairy Cows

    DEFF Research Database (Denmark)

    Thomsen, P T; Munksgaard, L; Tøgersen, F A

    2008-01-01

    Lameness is a major problem in dairy production both in terms of reduced production and compromised animal welfare. A 5-point lameness scoring system was developed based on previously published systems, but optimized for use under field conditions. The scoring system included the words "in most...... categories by different observers before or after training. In conclusion, the results suggest that the lameness categories were not equidistant and the scoring system has reasonable reliability in terms of intra- and interobserver agreement...

  3. Classifying snakebite in South Africa: Validating a scoring system ...

    African Journals Online (AJOL)

    Factors predictive of ATI and the optimal cut-off score for predicting an ATI were identified. These factors were then used to develop a standard scoring system. The score was then tested prospectively for accuracy in a new validation cohort consisting of 100 patients admitted for snakebite to our unit from 1 December 2014 to ...

  4. A Novel Scoring System Approach to Assess Patients with Lyme Disease (Nutech Functional Score)

    OpenAIRE

    Geeta Shroff; Petra Hopf-Seidel

    2018-01-01

    Introduction: A bacterial infection by Borrelia burgdorferi referred to as Lyme disease (LD) or borreliosis is transmitted mostly by a bite of the tick Ixodes scapularis in the USA and Ixodes ricinus in Europe. Various tests are used for the diagnosis of LD, but their results are often unreliable. We compiled a list of clinically visible and patient-reported symptoms that are associated with LD. Based on this list, we developed a novel scoring system. Methodology: Nutech functional Score (NF...

  5. How is the injury severity scored? a brief review of scoring systems

    Directory of Open Access Journals (Sweden)

    Mohsen Ebrahimi

    2015-06-01

    Full Text Available The management of injured patients is a critical issue in pre-hospital and emergency departments. Trauma victims are usually young and the injuries may lead to mortality or severe morbidities. The severity of injury can be estimated by observing the anatomic and physiologic evidences. Scoring systems are used to present a scale of describing the severity of the injuries in the victims.We reviewed the evidences of famous scoring systems, the history of their development, applications and their evolutions. We searched electronic database PubMed and Google scholar with keywords: (trauma OR injury AND (severity OR intensity AND (score OR scale.In this paper, we are going to present a definition of scoring systems and discuss the Abbreviated Injury Scale (AIS and Injury Severity Score (ISS, the most acceptable systems, their applications and their advantages and limitations.Several injury-scoring methods have been introduced. Each method has specific features, advantages and disadvantages. The AIS is an anatomical-based scoring system, which provides a standard numerical scale of ranking and comparing injuries. The ISS was established as a platform for trauma data registry. ISS is also an anatomically-based ordinal scale, with a range of 1-75. Several databases and studies are formed based on ISS and are available for trauma management research.Although the ISS is not perfect, it is established as the basic platform of health services and public health researches. The ISS registering system can provide many opportunities for the development of efficient data recording and statistical analyzing models.

  6. Successful introduction of Model for End-stage Liver Disease scoring in deceased donor liver transplantation in Korea: analysis of first 1 year experience at a high-volume transplantation center.

    Science.gov (United States)

    Ha, Soo-Min; Hwang, Shin; Song, Gi-Won; Ahn, Chul-Soo; Moon, Deok-Bog; Ha, Tae-Yong; Jung, Dong-Hwan; Park, Gil-Chun; Kim, Ki-Hun; Kim, Dae-Yeon; Namgung, Jungman; Kang, Woo-Hyoung; Kim, Seok-Hwan; Jwa, Eunkyoung; Kwon, Jae-Hyeon; Cho, Hui-Dong; Jung, Yong-Kyu; Kang, Sang-Hyeon; Lee, Sung-Gyu

    2017-11-01

    Model for End-stage Liver Disease (MELD) score was adopted in June 2016 in Korea. We analyzed changes in volumes and outcomes of deceased donor liver transplantation (DDLT) for 1 year before and after introduction of MELD scoring at Asan Medical Center. There were 64 cases of DDLT in 1 year before MELD introduction and 106 in 1 year after MELD introduction, an increase of 65%. The volume of DDLTs abruptly increased during first 3 months, but then returned to its usual level before MELD introduction, which indicated 3-month depletion of accumulated recipient pool with high MELD scores. The number of pediatric DDLT cases increased from 3 before MELD introduction to 11 after it, making up 21.4% and 47.8% of all cases of pediatric liver transplantation, respectively. The number of cases of retransplanted DDLTs increased from 4 to 27, representing 6.3% and 25.5% of all DDLT cases, respectively. The number of status 1 DDLT cases increased from 5 to 12, being 7.8% and 11.3% of all cases. Patient survival outcomes were similar before and after MELD introduction. The number of DDLTs temporarily increased after adoption of MELD scoring due to accumulated recipient pool with high MELD scores. The numbers of retransplanted and pediatric DDLT cases significantly increased. Patient survival in adult and pediatric DDLT was comparable before and after adoption of MELD scoring. These results imply that Korean MELD score-based allocation system was successfully established within its first year.

  7. Spectrophotometric investigation into iodine-electron donor systems at low temperature

    International Nuclear Information System (INIS)

    Gorodyskij, V.A.; Morachevskij, A.A.

    1978-01-01

    Iodine-sec. butanol (n-donor) and iodine - hexene - 1 (π-donor) have been investigated for the first time by the spectrophotometric method in the wide temeprature range (77-293 K). The existence of complexes with a charge transfer of the type, which is characterized by the long-wave absorption band in electron spectra, is determined in the systems

  8. Conformational dynamics of semiflexibly bridged electron donor-acceptor systems comprising long aliphatic tails

    NARCIS (Netherlands)

    Bleisteiner, B.; Marian, T.; Schneider, S.; Brouwer, A.M.; Verhoeven, J.W.

    2001-01-01

    In continuation of our previous work on the conformational dynamics (harpooning mechanism) of semiflexibly bridged electron donor-acceptor systems we have studied a derivative with two long aliphatic chains tethered to the donor and acceptor moieties, respectively. The fitting of the time- and

  9. Alvarado vs Lintula Scoring Systems in Acute Appendicitis | Ojuka ...

    African Journals Online (AJOL)

    The gold standard of diagnosis was histopathology. Data analysis was done using SPSS. The receiver operating characteristics, sensitivity, specificity, positive predictive values and negative predictive values of both scoring systems were then calculated for each of the scoring systems and compared between the two.

  10. Prognostic factors and scoring system for survival in colonic perforation.

    Science.gov (United States)

    Komatsu, Shuhei; Shimomatsuya, Takumi; Nakajima, Masayuki; Amaya, Hirokazu; Kobuchi, Taketsune; Shiraishi, Susumu; Konishi, Sayuri; Ono, Susumu; Maruhashi, Kazuhiro

    2005-01-01

    No ideal and generally accepted prognostic factors and scoring systems exist to determine the prognosis of peritonitis associated with colonic perforation. This study was designed to investigate prognostic factors and evaluate the various scoring systems to allow identification of high-risk patients. Between 1996 and 2003, excluding iatrogenic and trauma cases, 26 consecutive patients underwent emergency operations for colorectal perforation and were selected for this retrospective study. Several clinical factors were analyzed as possible predictive factors, and APACHE II, SOFA, MPI, and MOF scores were calculated. The overall mortality was 26.9%. Compared with the survivors, non-survivors were found more frequently in Hinchey's stage III-IV, a low preoperative marker of pH, base excess (BE), and a low postoperative marker of white blood cell count, PaO2/FiO2 ratio, and renal output (24h). According to the logistic regression model, BE was a significant independent variable. Concerning the prognostic scoring systems, an APACHE II score of 19, a SOFA score of 8, an MPI score of 30, and an MOF score of 7 or more were significantly related to poor prognosis. Preoperative BE and postoperative white blood cell count were reliable prognostic factors and early classification using prognostic scoring systems at specific points in the disease process are useful to improve our understanding of the problems involved.

  11. Symptom scoring systems to diagnose distal polyneuropathy in diabetes : the Diabetic Neuropathy Symptom score

    NARCIS (Netherlands)

    Meijer, J.W.G.; Smit, A.J.; van Sonderen, E.; Groothoff, J.W.; Eisma, W.H.; Links, T.P.

    2002-01-01

    AIMS: To provide one of the diagnostic categories for distal diabetic polyneuro-pathy,several symptom scoring systems are available, which are often extensive andlack in validation. We validated a new four-item Diabetic Neuropathy Symptom (DNS) scorefor diagnosing distal diabetic polyneuropathy.

  12. Sway Area and Velocity Correlated With MobileMat Balance Error Scoring System (BESS) Scores.

    Science.gov (United States)

    Caccese, Jaclyn B; Buckley, Thomas A; Kaminski, Thomas W

    2016-08-01

    The Balance Error Scoring System (BESS) is often used for sport-related concussion balance assessment. However, moderate intratester and intertester reliability may cause low initial sensitivity, suggesting that a more objective balance assessment method is needed. The MobileMat BESS was designed for objective BESS scoring, but the outcome measures must be validated with reliable balance measures. Thus, the purpose of this investigation was to compare MobileMat BESS scores to linear and nonlinear measures of balance. Eighty-eight healthy collegiate student-athletes (age: 20.0 ± 1.4 y, height: 177.7 ± 10.7 cm, mass: 74.8 ± 13.7 kg) completed the MobileMat BESS. MobileMat BESS scores were compared with 95% area, sway velocity, approximate entropy, and sample entropy. MobileMat BESS scores were significantly correlated with 95% area for single-leg (r = .332) and tandem firm (r = .474), and double-leg foam (r = .660); and with sway velocity for single-leg (r = .406) and tandem firm (r = .601), and double-leg (r = .575) and single-leg foam (r = .434). MobileMat BESS scores were not correlated with approximate or sample entropy. MobileMat BESS scores were low to moderately correlated with linear measures, suggesting the ability to identify changes in the center of mass-center of pressure relationship, but not higher-order processing associated with nonlinear measures. These results suggest that the MobileMat BESS may be a clinically-useful tool that provides objective linear balance measures.

  13. A Novel Scoring System Approach to Assess Patients with Lyme Disease (Nutech Functional Score).

    Science.gov (United States)

    Shroff, Geeta; Hopf-Seidel, Petra

    2018-01-01

    A bacterial infection by Borrelia burgdorferi referred to as Lyme disease (LD) or borreliosis is transmitted mostly by a bite of the tick Ixodes scapularis in the USA and Ixodes ricinus in Europe. Various tests are used for the diagnosis of LD, but their results are often unreliable. We compiled a list of clinically visible and patient-reported symptoms that are associated with LD. Based on this list, we developed a novel scoring system. Nutech functional Score (NFS), which is a 43 point positional (every symptom is subgraded and each alternative gets some points according to its position) and directional (moves in direction bad to good) scoring system that assesses the patient's condition. The grades of the scoring system have been converted into numeric values for conducting probability based studies. Each symptom is graded from 1 to 5 that runs in direction BAD → GOOD. NFS is a unique tool that can be used universally to assess the condition of patients with LD.

  14. A Novel Scoring System Approach to Assess Patients with Lyme Disease (Nutech Functional Score

    Directory of Open Access Journals (Sweden)

    Geeta Shroff

    2018-01-01

    Full Text Available Introduction: A bacterial infection by Borrelia burgdorferi referred to as Lyme disease (LD or borreliosis is transmitted mostly by a bite of the tick Ixodes scapularis in the USA and Ixodes ricinus in Europe. Various tests are used for the diagnosis of LD, but their results are often unreliable. We compiled a list of clinically visible and patient-reported symptoms that are associated with LD. Based on this list, we developed a novel scoring system. Methodology: Nutech functional Score (NFS, which is a 43 point positional (every symptom is subgraded and each alternative gets some points according to its position and directional (moves in direction bad to good scoring system that assesses the patient's condition. Results: The grades of the scoring system have been converted into numeric values for conducting probability based studies. Each symptom is graded from 1 to 5 that runs in direction BAD → GOOD. Conclusion: NFS is a unique tool that can be used universally to assess the condition of patients with LD.

  15. A scoring system for ascertainment of incident stroke; the Risk Index Score (RISc).

    Science.gov (United States)

    Kass-Hout, T A; Moyé, L A; Smith, M A; Morgenstern, L B

    2006-01-01

    The main objective of this study was to develop and validate a computer-based statistical algorithm that could be translated into a simple scoring system in order to ascertain incident stroke cases using hospital admission medical records data. The Risk Index Score (RISc) algorithm was developed using data collected prospectively by the Brain Attack Surveillance in Corpus Christi (BASIC) project, 2000. The validity of RISc was evaluated by estimating the concordance of scoring system stroke ascertainment to stroke ascertainment by physician and/or abstractor review of hospital admission records. RISc was developed on 1718 randomly selected patients (training set) and then statistically validated on an independent sample of 858 patients (validation set). A multivariable logistic model was used to develop RISc and subsequently evaluated by goodness-of-fit and receiver operating characteristic (ROC) analyses. The higher the value of RISc, the higher the patient's risk of potential stroke. The study showed RISc was well calibrated and discriminated those who had potential stroke from those that did not on initial screening. In this study we developed and validated a rapid, easy, efficient, and accurate method to ascertain incident stroke cases from routine hospital admission records for epidemiologic investigations. Validation of this scoring system was achieved statistically; however, clinical validation in a community hospital setting is warranted.

  16. Scoring the full extent of periodontal disease in the dog: development of a total mouth periodontal score (TMPS) system.

    Science.gov (United States)

    Harvey, Colin E; Laster, Larry; Shofer, Frances; Miller, Bonnie

    2008-09-01

    The development of a total mouth periodontal scoring system is described. This system uses methods to score the full extent of gingivitis and periodontitis of all tooth surfaces, weighted by size of teeth, and adjusted by size of dog.

  17. Classifying snakebite in South Africa: Validating a scoring system

    African Journals Online (AJOL)

    In addition, coagulopathy may not be identified until the patient manifests with ... To develop and validate a scoring system for managing snakebites in South Africa (SA). Methods. ... that its greatest value is in identifying those patients who do ...

  18. Scoring system to distinguish uncomplicated from complicated acute appendicitis

    NARCIS (Netherlands)

    Atema, J. J.; van Rossem, C. C.; Leeuwenburgh, M. M.; Stoker, J.; Boermeester, M. A.

    2015-01-01

    Non-operative management may be an alternative for uncomplicated appendicitis, but preoperative distinction between uncomplicated and complicated disease is challenging. This study aimed to develop a scoring system based on clinical and imaging features to distinguish uncomplicated from complicated

  19. The magazine picture collage: development of an objective scoring system.

    Science.gov (United States)

    Lerner, C; Ross, G

    1977-03-01

    A system for objectively scoring the magazine picture collage was developed and applied to the collages of 12 psychiatric inpatients and 12 paired controls. As a group, the patient collages had fewer cuttings, tended to lack an overall balance and central theme, and contained fewer pictures of people and more of animals. The results are consistent with those reported by other researchers as well as with general clinical experience, and as such, lend support to the construct validity of the scoring system.

  20. Advising potential recipients on the use of organs from donors with primary central nervous system tumors.

    Science.gov (United States)

    Warrens, Anthony N; Birch, Rhiannon; Collett, David; Daraktchiev, Maren; Dark, John H; Galea, George; Gronow, Katie; Neuberger, James; Hilton, David; Whittle, Ian R; Watson, Christopher J E

    2012-02-27

    Deciding to use an organ from a donor with a primary central nervous system (CNS) tumor necessitates offsetting the risk of tumor transmission with the chances of survival if the patient waits for another offer of a transplant. Published data vary in the quoted risk of tumor transmission. We used data obtained by reviewing 246 UK recipients of organs taken from donors with CNS tumors and found no evidence of a difference in overall patient mortality for recipients of a kidney, liver, or cardiothoracic organ, compared with recipients of organs from donors without a CNS tumor. Recent publication of the UK experience of transplanting organs from CNS tumor donors found no transmission in 448 recipients of organs from 177 donors with a primary CNS tumor (Watson et al., Am J Transplant 2010; 10: 1437). This 0% transmission rate is associated with an upper 95% confidence interval limit of 1.5%. Using a series of assumptions of risk, we compared the risks of dying as a result of the transmission of a primary brain tumor with the risks of dying if not transplanted. On this basis, the use of kidneys from a donor with a primary CNS tumor provides a further 8 years of life over someone who waited for a donor who did not have a primary CNS tumor, in addition to the life years gained by the transplant itself. The benefits for the recipients of livers and cardiothoracic organs were less, but there was no disadvantage in the impact on life expectancy.

  1. Nutech functional score: A novel scoring system to assess spinal cord injury patients.

    Science.gov (United States)

    Shroff, Geeta; Barthakur, Jitendra Kumar

    2017-06-26

    To develop a new scoring system, nutech functional scores (NFS) for assessing the patients with spinal cord injury (SCI). The conventional scale, American Spinal Injury Association's (ASIA) impairment scale is a measure which precisely describes the severity of the SCI. However, it has various limitations which lead to incomplete assessment of SCI patients. We have developed a 63 point scoring system, i . e ., NFS for patients suffering with SCI. A list of symptoms either common or rare that were found to be associated with SCI was recorded for each patient. On the basis of these lists, we have developed NFS. These lists served as a base to prepare NFS, a 63 point positional (each symptom is sub-graded and get points based on position) and directional (moves in direction BAD → GOOD) scoring system. For non-progressive diseases, 1, 2, 3, 4, 5 denote worst, bad, moderate, good and best (normal), respectively. NFS for SCI has been divided into different groups based on the affected part of the body being assessed, i . e ., motor assessment (shoulders, elbow, wrist, fingers-grasp, fingers-release, hip, knee, ankle and toe), sensory assessment, autonomic assessment, bed sore assessment and general assessment. As probability based studies required a range of (-1, 1) or at least the range of (0, 1) to be useful for real world analysis, the grades were converted to respective numeric values. NFS can be considered as a unique tool to assess the improvement in patients with SCI as it overcomes the limitations of ASIA impairment scale.

  2. Disease scoring systems for oral lichen planus; a critical appraisal

    Science.gov (United States)

    Wang, Jing

    2015-01-01

    The aim of the present study has been to critically review 22 disease scoring systems (DSSs) on oral lichen planus (OLP) that have been reported in the literature during the past decades. Although the presently available DSSs may all have some merit, particularly for research purposes, the diversity of both the objective and subjective parameters used in these systems and the lack of acceptance of one of these systems for uniform use, there is a need for an international, authorized consensus meeting on this subject. Because of the natural course of OLP characterized by remissions and exacerbations and also due to the varying distribution pattern and the varying clinical types, e.g. reticular and erosive, the relevance of a DSS based on morphologic parameters is somewhat questionable. Instead, one may consider to only look for a quality of life scoring system adapted for use in OLP patients. Key words:Oral lichen planus, disease scoring system, classification. PMID:25681372

  3. SYSTEMIC COMPLICATIONS AND THEIR RISK FACTORS AMONG TEHRANIAN BLOOD DONOR, 2005

    OpenAIRE

    F. Majlessi; S. Ghafari; A. Rahimi-Foroushani M. Maghsoodlou

    2008-01-01

    The systemic complications of blood donation are the first reasons why patients fail to return for further blood donation. This study was designed to determine the frequency of these complications and their associated risk factors among blood donors in Tehran. Also, we aimed to provide suitable methods to decrease the frequency of these adverse events, thereby eliminating the most important causes of withdrawal, while maintaining the health of the donors. This analytical descriptive cross-sec...

  4. Severity scoring in the critically ill: part 2: maximizing value from outcome prediction scoring systems.

    Science.gov (United States)

    Breslow, Michael J; Badawi, Omar

    2012-02-01

    Part 2 of this review of ICU scoring systems examines how scoring system data should be used to assess ICU performance. There often are two different consumers of these data: lCU clinicians and quality leaders who seek to identify opportunities to improve quality of care and operational efficiency, and regulators, payors, and consumers who want to compare performance across facilities. The former need to know how to garner maximal insight into their care practices; this includes understanding how length of stay (LOS) relates to quality, analyzing the behavior of different subpopulations, and following trends over time. Segregating patients into low-, medium-, and high-risk populations is especially helpful, because care issues and outcomes may differ across this severity continuum. Also, LOS behaves paradoxically in high-risk patients (survivors often have longer LOS than nonsurvivors); failure to examine this subgroup separately can penalize ICUs with superior outcomes. Consumers of benchmarking data often focus on a single score, the standardized mortality ratio (SMR). However, simple SMRs are disproportionately affected by outcomes in high-risk patients, and differences in population composition, even when performance is otherwise identical, can result in different SMRs. Future benchmarking must incorporate strategies to adjust for differences in population composition and report performance separately for low-, medium- and high-acuity patients. Moreover, because many ICUs lack the resources to care for high-acuity patients (predicted mortality >50%), decisions about where patients should receive care must consider both ICU performance scores and their capacity to care for different types of patients.

  5. SYSTEMIC COMPLICATIONS AND THEIR RISK FACTORS AMONG TEHRANIAN BLOOD DONOR, 2005

    Directory of Open Access Journals (Sweden)

    F. Majlessi

    2008-06-01

    Full Text Available The systemic complications of blood donation are the first reasons why patients fail to return for further blood donation. This study was designed to determine the frequency of these complications and their associated risk factors among blood donors in Tehran. Also, we aimed to provide suitable methods to decrease the frequency of these adverse events, thereby eliminating the most important causes of withdrawal, while maintaining the health of the donors. This analytical descriptive cross-sectional study was performed on 554 blood donors who had donated blood from February 2005 through September 2005 in four fixed blood donation bases and four mobile blood collection buses. Each base was considered as a stratum, and a stratified random sampling proportional to size was done to select the donors. Results showed donor reaction rate to be 13.4%, the most common of which were blackout of vision (7%, dizziness (6.3%, fatigue (6.1% and nausea (1.8%. There was no significant relationship between the incidence of these complications and type of base blood donation or fasting at the time of blood donation. Logistic Regression analysis showed that sex, condition of blood donor, exercise or walking, duration of donation, and practice to recommendation had significant effects on the odds ratio of systemic complication. Regarding the frequency values derived for the different systemic complications it can be concluded that attention to risk factors of these complications and their control can help encourage donors to become repeated donors as well as to prevent their withdrawal for further blood donation.

  6. Nanographenes as electron-deficient cores of donor-acceptor systems.

    Science.gov (United States)

    Liu, Yu-Min; Hou, Hao; Zhou, Yan-Zhen; Zhao, Xin-Jing; Tang, Chun; Tan, Yuan-Zhi; Müllen, Klaus

    2018-05-15

    Conjugation of nanographenes (NGs) with electro-active molecules can establish donor-acceptor π-systems in which the former generally serve as the electron-donating moieties due to their electronic-rich nature. In contrast, here we report a series of reversed donor-acceptor structures are obtained by C-N coupling of electron-deficient perchlorinated NGs with electron-rich anilines. Selective amination at the vertexes of the NGs is unambiguously shown through X-ray crystallography. By varying the donating ability of the anilino groups, the optical and assembly properties of donor-acceptor NGs can be finely modulated. The electron-deficient concave core of the resulting conjugates can host electron-rich guest molecules by intermolecular donor-acceptor interactions and gives rise to charge-transfer supramolecular architectures.

  7. Alvarado vs Lintula Scoring Systems in Acute Appendicitis

    African Journals Online (AJOL)

    communication. Clinicians attending to these patients were continuously appraised and trained on the two scoring systems to be compared including the cut off points for diagnosis. This was done by one author or a trained research assistant who was a qualified clinical officer. A written card with the two systems was placed ...

  8. Changes in the organ procurement system in South Korea: effects on brain-dead donor numbers.

    Science.gov (United States)

    Lee, S D; Kim, J H

    2009-11-01

    In Korea, the Organ Transplantation Act came into effect in 2000, establishing the Korean Network for Organ Sharing (KONOS) with centralized authority for organ procurement as well as for approval of donors and recipients to ensure fair organ allocation. However, the number of brain-dead donors decreased sharply, and the organ allocation system proved inefficient. The government revised the Organ Transplantation Act in August 2002, introducing an incentive system. If a transplantation hospital formed a Committee for Brain Death Evaluation and a Hospital Organ Procurement Organization, it could receive a kidney from a brain dead-donor as an incentive to foster organ procurement regardless of the KONOS wait list. The government also launched a pilot brain-dead donor registry program to strengthen Hospital Organ Procurement Organization activity. If local hospitals collaborated with specialized hospitals in organ procurement, local hospitals obtained financial incentives. But because the organ shortage problem has not been resolved, the government has proposed four initiatives: first, broadening the incentive system, which makes it possible to give each specialized hospital a choice of one of eight organs from each donor as an incentive; second, development of an Independent Organ Procurement Organization; third introduction of an opt-out system; and last, improvement of the Committee for Brain Death Evaluation system. It is uncertain which initiatives will be adopted, but changes in organ procurement systems are nonetheless considered a key to solve the organ shortage problem in Korea.

  9. Building an Image-Based System to automatically Score psoriasis

    DEFF Research Database (Denmark)

    G{'o}mez, D. Delgado; Carstensen, Jens Michael; Ersbøll, Bjarne Kjær

    2003-01-01

    Nowadays the medical tracking of dermatological diseases is imprecise. The main reason is the lack of suitable objective methods to evaluate the lesion. The severity of the disease is scored by doctors just through their visual examination. In this work, a system to take accurate images of dermat......Nowadays the medical tracking of dermatological diseases is imprecise. The main reason is the lack of suitable objective methods to evaluate the lesion. The severity of the disease is scored by doctors just through their visual examination. In this work, a system to take accurate images...

  10. Peritumoral Artery Scoring System: a Novel Scoring System to Predict Renal Function Outcome after Laparoscopic Partial Nephrectomy.

    Science.gov (United States)

    Zhang, Ruiyun; Wu, Guangyu; Huang, Jiwei; Shi, Oumin; Kong, Wen; Chen, Yonghui; Xu, Jianrong; Xue, Wei; Zhang, Jin; Huang, Yiran

    2017-06-06

    The present study aimed to assess the impact of peritumoral artery characteristics on renal function outcome prediction using a novel Peritumoral Artery Scoring System based on computed tomography arteriography. Peritumoral artery characteristics and renal function were evaluated in 220 patients who underwent laparoscopic partial nephrectomy and then validate in 51 patients with split and total glomerular filtration rate (GFR). In particular, peritumoral artery classification and diameter were measured to assign arteries into low, moderate, and high Peritumoral Artery Scoring System risk categories. Univariable and multivariable logistic regression analyses were then used to determine risk factors for major renal functional decline. The Peritumoral Artery Scoring System and four other nephrometry systems were compared using receiver operating characteristic curve analysis. The Peritumoral Artery Scoring System was significantly superior to the other systems for predicting postoperative renal function decline (p system was a superior independent predictor of estimated glomerular filtration rate (eGFR) decline (area-under-the-curve = 0.865, p renal function outcome after laparoscopic partial nephrectomy.

  11. Disease scoring systems for oral lichen planus; a critical appraisal

    NARCIS (Netherlands)

    Wang, J.; van der Waal, I.

    2015-01-01

    The aim of the present study has been to critically review 22 disease scoring systems (DSSs) on oral lichen planus (OLP) that have been reported in the literature during the past decades. Although the presently available DSSs may all have some merit, particularly for research purposes, the diversity

  12. Photochromic and electrochromic performances of new types of donor/acceptor systems based on crosslinked polyviologen film and electron donors

    International Nuclear Information System (INIS)

    Gao Liping; Ding Guojing; Li Chaolong; Wang Yuechuan

    2011-01-01

    Viologen-functionalized copolymer COPV 2+ was synthesized by copolymer graft-modified, which was crosslinked by NH 3 .H 2 O gas-fumigated at 25 deg. C for 4 h due to the condensation of the siloxanes of COPV 2+ film. Simultaneously, different donor/acceptor systems had been prepared based on crosslinked polyviologen film (COPV 2+ ) and N,N,N',N'-tetramethyl-1,4-phenylenediamine (TMPD) or hydroxyethylferrocene (HEFc) in order to shorten the response times and improve contrast ratios in response to external photo- and potential stimuli. The evolution of structures from COPO to COPV 2+ is carefully characterized. The COPV 2+ /TMPD and COPV 2+ /HEFc films exhibited both photochromic and electrochromic performances. After UV irradiations, COPV 2+ /TMPD and COPV 2+ /HEFc films changed their colors from colorless to deep blue, while optical transmissions at 610 nm decreased about 64% and 75%, respectively. When removing out from UV irradiation, the colored COPV 2+ /TMPD and COPV 2+ /HEFc films faded to the original colors within about 60 min. When COPV 2+ /TMPD and COPV 2+ /HEFc films were biased with negative voltage of -2.5 V, they changed their colors from colorless to deep blue in 4 s and 3 s, while the optical transmissions at 556 nm decreased about 81% and 75%, respectively. When electric impulse was switched off, the colored COPV 2+ /TMPD and COPV 2+ /HEFc films faded to the original colors within about 7 s and 6 s, respectively.

  13. A prognostic scoring system for arm exercise stress testing.

    Science.gov (United States)

    Xie, Yan; Xian, Hong; Chandiramani, Pooja; Bainter, Emily; Wan, Leping; Martin, Wade H

    2016-01-01

    Arm exercise stress testing may be an equivalent or better predictor of mortality outcome than pharmacological stress imaging for the ≥50% for patients unable to perform leg exercise. Thus, our objective was to develop an arm exercise ECG stress test scoring system, analogous to the Duke Treadmill Score, for predicting outcome in these individuals. In this retrospective observational cohort study, arm exercise ECG stress tests were performed in 443 consecutive veterans aged 64.1 (11.1) years. (mean (SD)) between 1997 and 2002. From multivariate Cox models, arm exercise scores were developed for prediction of 5-year and 12-year all-cause and cardiovascular mortality and 5-year cardiovascular mortality or myocardial infarction (MI). Arm exercise capacity in resting metabolic equivalents (METs), 1 min heart rate recovery (HRR) and ST segment depression ≥1 mm were the stress test variables independently associated with all-cause and cardiovascular mortality by step-wise Cox analysis (all pstatistic of 0.81 before and 0.88 after adjustment for significant demographic and clinical covariates. Arm exercise scores for the other outcome end points yielded C-statistic values of 0.77-0.79 before and 0.82-0.86 after adjustment for significant covariates versus 0.64-0.72 for best fit pharmacological myocardial perfusion imaging models in a cohort of 1730 veterans who were evaluated over the same time period. Arm exercise scores, analogous to the Duke Treadmill Score, have good power for prediction of mortality or MI in patients who cannot perform leg exercise.

  14. The OMERACT rheumatoid arthritis magnetic resonance imaging (MRI) scoring system

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Peterfy, Charles G.; Bird, Paul

    2017-01-01

    Objective: The Outcome Measures in Rheumatology (OMERACT) Rheumatoid Arthritis (RA) Magnetic Resonance Imaging (MRI) scoring system (RAMRIS), evaluating bone erosion, bone marrow edema/osteitis, and synovitis, was introduced in 2002, and is now the standard method of objectively quantifying...... inflammation and damage by MRI in RA trials. The objective of this paper was to identify subsequent advances and based on them, to provide updated recommendations for the RAMRIS. Methods: MRI studies relevant for RAMRIS and technical and scientific advances were analyzed by the OMERACT MRI in Arthritis Working...... Group, which used these data to provide updated considerations on image acquisition, RAMRIS definitions, and scoring systems for the original and new RA pathologies. Further, a research agenda was outlined. Results: Since 2002, longitudinal studies and clinical trials have documented RAMRIS variables...

  15. Mechanism and Dynamics of Charge Transfer in Donor-Bridge-Acceptor Systems

    NARCIS (Netherlands)

    Gorczak-Vos, N.

    2016-01-01

    Photoinduced charge transfer in organic materials is a fundamental process in various biological and technological areas. Donor-bridge-acceptor (DBA) molecules are used as model systems in numerous theoretical and experimental work to systematically study and unravel the underlying mechanisms of

  16. Scoring systems of severity in patients with multiple trauma.

    Science.gov (United States)

    Rapsang, Amy Grace; Shyam, Devajit Chowlek

    2015-04-01

    Trauma is a major cause of morbidity and mortality; hence severity scales are important adjuncts to trauma care in order to characterize the nature and extent of injury. Trauma scoring models can assist with triage and help in evaluation and prediction of prognosis in order to organise and improve trauma systems. Given the wide variety of scoring instruments available to assess the injured patient, it is imperative that the choice of the severity score accurately match the application. Even though trauma scores are not the key elements of trauma treatment, they are however, an essential part of improvement in triage decisions and in identifying patients with unexpected outcomes. This article provides the reader with a compendium of trauma severity scales along with their predicted death rate calculation, which can be adopted in order to improve decision making, trauma care, research and in comparative analyses in quality assessment. Copyright © 2013 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Selecting a pharmacy layout design using a weighted scoring system.

    Science.gov (United States)

    McDowell, Alissa L; Huang, Yu-Li

    2012-05-01

    A weighted scoring system was used to select a pharmacy layout redesign. Facilities layout design techniques were applied at a local hospital pharmacy using a step-by-step design process. The process involved observing and analyzing the current situation, observing the current available space, completing activity flow charts of the pharmacy processes, completing communication and material relationship charts to detail which areas in the pharmacy were related to one another and how they were related, researching applications in other pharmacies or in scholarly works that could be beneficial, numerically defining space requirements for areas within the pharmacy, measuring the available space within the pharmacy, developing a set of preliminary designs, and modifying preliminary designs so they were all acceptable to the pharmacy staff. To select a final layout that could be implemented in the pharmacy, those layouts were compared via a weighted scoring system. The weighted aspect further allowed additional emphasis on categories based on their effect on pharmacy performance. The results produced a beneficial layout design as determined through simulated models of the pharmacy operation that more effectively allocated and strategically located space to improve transportation distances and materials handling, employee utilization, and ergonomics. Facilities layout designs for a hospital pharmacy were evaluated using a weighted scoring system to identify a design that was superior to both the current layout and alternative layouts in terms of feasibility, cost, patient safety, employee safety, flexibility, robustness, transportation distance, employee utilization, objective adherence, maintainability, usability, and environmental impact.

  18. A Novel Risk Scoring System Reliably Predicts Readmission Following Pancreatectomy

    Science.gov (United States)

    Valero, Vicente; Grimm, Joshua C.; Kilic, Arman; Lewis, Russell L.; Tosoian, Jeffrey J.; He, Jin; Griffin, James; Cameron, John L.; Weiss, Matthew J.; Vollmer, Charles M.; Wolfgang, Christopher L.

    2015-01-01

    Background Postoperative readmissions have been proposed by Medicare as a quality metric and may impact provider reimbursement. Since readmission following pancreatectomy is common, we sought to identify factors associated with readmission in order to establish a predictive risk scoring system (RSS). Study Design A retrospective analysis of 2,360 pancreatectomies performed at nine, high-volume pancreatic centers between 2005 and 2011 was performed. Forty-five factors strongly associated with readmission were identified. To derive and validate a RSS, the population was randomly divided into two cohorts in a 4:1 fashion. A multivariable logistic regression model was constructed and scores were assigned based on the relative odds ratio of each independent predictor. A composite Readmission After Pancreatectomy (RAP) score was generated and then stratified to create risk groups. Results Overall, 464 (19.7%) patients were readmitted within 90-days. Eight pre- and postoperative factors, including prior myocardial infarction (OR 2.03), ASA Class ≥ 3 (OR 1.34), dementia (OR 6.22), hemorrhage (OR 1.81), delayed gastric emptying (OR 1.78), surgical site infection (OR 3.31), sepsis (OR 3.10) and short length of stay (OR 1.51), were independently predictive of readmission. The 32-point RAP score generated from the derivation cohort was highly predictive of readmission in the validation cohort (AUC 0.72). The low (0-3), intermediate (4-7) and high risk (>7) groups correlated to 11.7%, 17.5% and 45.4% observed readmission rates, respectively (preadmission following pancreatectomy. Identification of patients with increased risk of readmission using the RAP score will allow efficient resource allocation aimed to attenuate readmission rates. It also has potential to serve as a new metric for comparative research and quality assessment. PMID:25797757

  19. The Weighted Airman Promotion System: Standardizing Test Scores

    Science.gov (United States)

    2008-01-01

    u th o ri ze d Top 3/E6 ratio, inventory 1401206040 100 70 130 5R 2F 2G 3N 2M 2A 4J 4C 4P 4T 4B 1W 2T 3P 1T 4A 2S 5J 1A 1S1C 6F 4N 7S 4R 4E 1N 3A 3V...System: Standardizing Test Scores AFHRL convened a panel to identify the relevant factors to consider, and then sit as a promotion board and rank...Costs If the Air Force decided to standardize test scores, there would be three basic types of costs: implementation costs, marketing costs, and

  20. Scoring system development for prediction of extravesical bladder cancer

    Directory of Open Access Journals (Sweden)

    Prelević Rade

    2014-01-01

    Full Text Available Background/Aim. Staging of bladder cancer is crucial for optimal management of the disease. However, clinical staging is not perfectly accurate. The aim of this study was to derive a simple scoring system in prediction of pathological advanced muscle-invasive bladder cancer (MIBC. Methods. Logistic regression and bootstrap methods were used to create an integer score for estimating the risk in prediction of pathological advanced MIBC using precystectomy clinicopathological data: demographic, initial transurethral resection (TUR [grade, stage, multiplicity of tumors, lymphovascular invasion (LVI], hydronephrosis, abdominal and pelvic CT radiography (size of the tumor, tumor base width, and pathological stage after radical cystectomy (RC. Advanced MIBC in surgical specimen was defined as pT3-4 tumor. Receiving operating characteristic (ROC curve quantified the area under curve (AUC as predictive accuracy. Clinical usefulness was assessed by using decision curve analysis. Results. This single-center retrospective study included 233 adult patients with BC undergoing RC at the Military Medical Academy, Belgrade. Organ confined disease was observed in 101 (43.3% patients, and 132 (56.7% had advanced MIBC. In multivariable analysis, 3 risk factors most strongly associated with advanced MIBC: grade of initial TUR [odds ratio (OR = 4.7], LVI (OR = 2, and hydronephrosis (OR = 3.9. The resultant total possible score ranged from 0 to 15, with the cut-off value of > 8 points, the AUC was 0.795, showing good discriminatory ability. The model showed excellent calibration. Decision curve analysis showed a net benefit across all threshold probabilities and clinical usefulness of the model. Conclusion. We developed a unique scoring system which could assist in predicting advanced MIBC in patients before RC. The scoring system showed good performance characteristics and introducing of such a tool into daily clinical decision-making may lead to more appropriate

  1. External validation of the NOBLADS score, a risk scoring system for severe acute lower gastrointestinal bleeding.

    Directory of Open Access Journals (Sweden)

    Tomonori Aoki

    Full Text Available We aimed to evaluate the generalizability of NOBLADS, a severe lower gastrointestinal bleeding (LGIB prediction model which we had previously derived when working at a different institution, using an external validation cohort. NOBLADS comprises the following factors: non-steroidal anti-inflammatory drug use, no diarrhea, no abdominal tenderness, blood pressure ≤ 100 mmHg, antiplatelet drug use, albumin < 3.0 g/dL, disease score ≥ 2, and syncope.We retrospectively analyzed 511 patients emergently hospitalized for acute LGIB at the University of Tokyo Hospital, from January 2009 to August 2016. The areas under the receiver operating characteristic curves (ROCs-AUCs for severe bleeding (continuous and/or recurrent bleeding were compared between the original derivation cohort and the external validation cohort.Severe LGIB occurred in 44% of patients. Several clinical factors were significantly different between the external and derivation cohorts (p < 0.05, including background, laboratory data, NOBLADS scores, and diagnosis. The NOBLADS score predicted the severity of LGIB with an AUC value of 0.74 in the external validation cohort and one of 0.77 in the derivation cohort. In the external validation cohort, the score predicted the risk for blood transfusion need (AUC, 0.71, but was not adequate for predicting intervention need (AUC, 0.54. The in-hospital mortality rate was higher in patients with a score ≥ 5 than in those with a score < 5 (AUC, 0.83.Although the external validation cohort clinically differed from the derivation cohort in many ways, we confirmed the moderately high generalizability of NOBLADS, a clinical risk score for severe LGIB. Appropriate triage using this score may support early decision-making in various hospitals.

  2. Organic charge transfer phase formation in thin films of the BEDT-TTF/TCNQ donor-acceptor system

    DEFF Research Database (Denmark)

    Solovyeva, Vita; Keller, K.; Huth, M.

    2009-01-01

    We have performed charge transfer phase formation studies on the donor/acceptor system bis-(ethylendithio)tetrathiafulvalene (BEDT-TTF)/tetracyanoquinodimethane,(TCNQ) by means of physical vapor deposition. We prepared donor/acceptor bilayer structures on glass and Si(100)/SiO substrates held...

  3. Development and validation of a composite scoring system for robot-assisted surgical training--the Robotic Skills Assessment Score.

    Science.gov (United States)

    Chowriappa, Ashirwad J; Shi, Yi; Raza, Syed Johar; Ahmed, Kamran; Stegemann, Andrew; Wilding, Gregory; Kaouk, Jihad; Peabody, James O; Menon, Mani; Hassett, James M; Kesavadas, Thenkurussi; Guru, Khurshid A

    2013-12-01

    A standardized scoring system does not exist in virtual reality-based assessment metrics to describe safe and crucial surgical skills in robot-assisted surgery. This study aims to develop an assessment score along with its construct validation. All subjects performed key tasks on previously validated Fundamental Skills of Robotic Surgery curriculum, which were recorded, and metrics were stored. After an expert consensus for the purpose of content validation (Delphi), critical safety determining procedural steps were identified from the Fundamental Skills of Robotic Surgery curriculum and a hierarchical task decomposition of multiple parameters using a variety of metrics was used to develop Robotic Skills Assessment Score (RSA-Score). Robotic Skills Assessment mainly focuses on safety in operative field, critical error, economy, bimanual dexterity, and time. Following, the RSA-Score was further evaluated for construct validation and feasibility. Spearman correlation tests performed between tasks using the RSA-Scores indicate no cross correlation. Wilcoxon rank sum tests were performed between the two groups. The proposed RSA-Score was evaluated on non-robotic surgeons (n = 15) and on expert-robotic surgeons (n = 12). The expert group demonstrated significantly better performance on all four tasks in comparison to the novice group. Validation of the RSA-Score in this study was carried out on the Robotic Surgical Simulator. The RSA-Score is a valid scoring system that could be incorporated in any virtual reality-based surgical simulator to achieve standardized assessment of fundamental surgical tents during robot-assisted surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Normative Data for the Balance Error Scoring System in Adults

    Directory of Open Access Journals (Sweden)

    Grant L. Iverson

    2013-01-01

    Full Text Available Background. The balance error scoring system (BESS is a brief, easily administered test of static balance. The purpose of this study is to develop normative data for this test. Study Design. Cross-sectional, descriptive, and cohort design. Methods. The sample was drawn from a population of clients taking part in a comprehensive preventive health screen at a multidisciplinary healthcare center. Community-dwelling adults aged 20–69 (N=1,236 were administered the BESS within the context of a fitness evaluation. They did not have significant medical, neurological, or lower extremity problems that might have an adverse effect on balance. Results. There was a significant positive correlation between BESS scores and age (r=.34. BESS performance was similar for participants between the ages of 20 and 49 and significantly declined between ages 50 and 69. Men performed slightly better than women on the BESS. Women who were overweight performed significantly more poorly on the test compared to women who were not overweight (P<.0001; Cohen's d=.62. The BESS normative data are stratified by age and sex. Conclusions. These normative data provide a frame of reference for interpreting BESS performance in adults who sustain traumatic brain injuries and adults with diverse neurological or vestibular problems.

  5. Natural history of alkaptonuria revisited: analyses based on scoring systems.

    Science.gov (United States)

    Ranganath, Lakshminarayan R; Cox, Trevor F

    2011-12-01

    Increased circulating homogentisic acid in body fluids occurs in alkaptonuria (AKU) due to lack of enzyme homogentisate dioxygenase leading in turn to conversion of HGA to a pigmented melanin-like polymer, known as ochronosis. The tissue damage in AKU is due to ochronosis. A potential treatment, a drug called nitisinone, to decrease formation of HGA is available. However, deploying nitisinone effectively requires its administration at the most optimal time in the natural history. AKU has a long apparent latent period before overt ochronosis develops. The rate of change of ochronosis and its consequences over time following its recognition has not been fully described in any quantitative manner. Two potential tools are described that were used to quantitate disease burden in AKU. One tool describes scoring the clinical features that includes clinical assessments, investigations and questionnaires in 15 patients with AKU. The second tool describes a scoring system that only includes items obtained from questionnaires in 44 people with AKU. Analysis of the data reveals distinct phases of the disease, a pre-ochronotic phase and an ochronotic phase. The ochronotic phase appears to demonstrate an earlier slower progression followed by a rapidly progressive phase. The rate of change of the disease will have implications for monitoring the course of the disease as well as decide on the most appropriate time that treatment should be started for it to be effective either in prevention or arrest of the disease.

  6. Description and validation of a scoring system for tomosynthesis in pulmonary cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Vult von Steyern, Kristina; Bjoerkman-Burtscher, Isabella M.; Bozovic, Gracijela; Wiklund, Marie; Geijer, Mats [Skaane University Hospital, Lund University, Centre for Medical Imaging and Physiology, Lund (Sweden); Hoeglund, Peter [Skaane University Hospital, Competence Centre for Clinical Research, Lund (Sweden)

    2012-12-15

    To design and validate a scoring system for tomosynthesis (digital tomography) in pulmonary cystic fibrosis. A scoring system dedicated to tomosynthesis in pulmonary cystic fibrosis was designed. Three radiologists independently scored 88 pairs of radiographs and tomosynthesis examinations of the chest in 60 patients with cystic fibrosis and 7 oncology patients. Radiographs were scored according to the Brasfield scoring system and tomosynthesis examinations were scored using the new scoring system. Observer agreements for the tomosynthesis score were almost perfect for the total score with square-weighted kappa >0.90, and generally substantial to almost perfect for subscores. Correlation between the tomosynthesis score and the Brasfield score was good for the three observers (Kendall's rank correlation tau 0.68, 0.77 and 0.78). Tomosynthesis was generally scored higher as a percentage of the maximum score. Observer agreements for the total score for Brasfield score were almost perfect (square-weighted kappa 0.80, 0.81 and 0.85). The tomosynthesis scoring system seems robust and correlates well with the Brasfield score. Compared with radiography, tomosynthesis is more sensitive to cystic fibrosis changes, especially bronchiectasis and mucus plugging, and the new tomosynthesis scoring system offers the possibility of more detailed and accurate scoring of disease severity. (orig.)

  7. Description and validation of a scoring system for tomosynthesis in pulmonary cystic fibrosis.

    Science.gov (United States)

    Vult von Steyern, Kristina; Björkman-Burtscher, Isabella M; Höglund, Peter; Bozovic, Gracijela; Wiklund, Marie; Geijer, Mats

    2012-12-01

    To design and validate a scoring system for tomosynthesis (digital tomography) in pulmonary cystic fibrosis. A scoring system dedicated to tomosynthesis in pulmonary cystic fibrosis was designed. Three radiologists independently scored 88 pairs of radiographs and tomosynthesis examinations of the chest in 60 patients with cystic fibrosis and 7 oncology patients. Radiographs were scored according to the Brasfield scoring system and tomosynthesis examinations were scored using the new scoring system. Observer agreements for the tomosynthesis score were almost perfect for the total score with square-weighted kappa >0.90, and generally substantial to almost perfect for subscores. Correlation between the tomosynthesis score and the Brasfield score was good for the three observers (Kendall's rank correlation tau 0.68, 0.77 and 0.78). Tomosynthesis was generally scored higher as a percentage of the maximum score. Observer agreements for the total score for Brasfield score were almost perfect (square-weighted kappa 0.80, 0.81 and 0.85). The tomosynthesis scoring system seems robust and correlates well with the Brasfield score. Compared with radiography, tomosynthesis is more sensitive to cystic fibrosis changes, especially bronchiectasis and mucus plugging, and the new tomosynthesis scoring system offers the possibility of more detailed and accurate scoring of disease severity. Tomosynthesis is more sensitive than conventional radiography for pulmonary cystic fibrosis changes. The radiation dose from chest tomosynthesis is low compared with computed tomography. Tomosynthesis may become useful in the regular follow-up of patients with cystic fibrosis.

  8. Description and validation of a scoring system for tomosynthesis in pulmonary cystic fibrosis

    International Nuclear Information System (INIS)

    Vult von Steyern, Kristina; Bjoerkman-Burtscher, Isabella M.; Bozovic, Gracijela; Wiklund, Marie; Geijer, Mats; Hoeglund, Peter

    2012-01-01

    To design and validate a scoring system for tomosynthesis (digital tomography) in pulmonary cystic fibrosis. A scoring system dedicated to tomosynthesis in pulmonary cystic fibrosis was designed. Three radiologists independently scored 88 pairs of radiographs and tomosynthesis examinations of the chest in 60 patients with cystic fibrosis and 7 oncology patients. Radiographs were scored according to the Brasfield scoring system and tomosynthesis examinations were scored using the new scoring system. Observer agreements for the tomosynthesis score were almost perfect for the total score with square-weighted kappa >0.90, and generally substantial to almost perfect for subscores. Correlation between the tomosynthesis score and the Brasfield score was good for the three observers (Kendall's rank correlation tau 0.68, 0.77 and 0.78). Tomosynthesis was generally scored higher as a percentage of the maximum score. Observer agreements for the total score for Brasfield score were almost perfect (square-weighted kappa 0.80, 0.81 and 0.85). The tomosynthesis scoring system seems robust and correlates well with the Brasfield score. Compared with radiography, tomosynthesis is more sensitive to cystic fibrosis changes, especially bronchiectasis and mucus plugging, and the new tomosynthesis scoring system offers the possibility of more detailed and accurate scoring of disease severity. (orig.)

  9. Risk-adjusted scoring systems in colorectal surgery.

    Science.gov (United States)

    Leung, Edmund; McArdle, Kirsten; Wong, Ling S

    2011-01-01

    Consequent to recent advances in surgical techniques and management, survival rate has increased substantially over the last 25 years, particularly in colorectal cancer patients. However, post-operative morbidity and mortality from colorectal cancer vary widely across the country. Therefore, standardised outcome measures are emphasised not only for professional accountability, but also for comparison between treatment units and regions. In a heterogeneous population, the use of crude mortality as an outcome measure for patients undergoing surgery is simply misleading. Meaningful comparisons, however, require accurate risk stratification of patients being analysed before conclusions can be reached regarding the outcomes recorded. Sub-specialised colorectal surgical units usually dedicated to more complex and high-risk operations. The need for accurate risk prediction is necessary in these units as both mortality and morbidity often are tools to justify the practice of high-risk surgery. The Acute Physiology And Chronic Health Evaluation (APACHE) is a system for classifying patients in the intensive care unit. However, APACHE score was considered too complex for general surgical use. The American Society of Anaesthesiologists (ASA) grade has been considered useful as an adjunct to informed consent and for monitoring surgical performance through time. ASA grade is simple but too subjective. The Physiological & Operative Severity Score for the enUmeration of Mortality and morbidity (POSSUM) and its variant Portsmouth POSSUM (P-POSSUM) were devised to predict outcomes in surgical patients in general, taking into account of the variables in the case-mix. POSSUM has two parts, which include assessment of physiological parameters and operative scores. There are 12 physiological parameters and 6 operative measures. The physiological parameters are taken at the time of surgery. Each physiological parameter or operative variable is sub-divided into three or four levels with

  10. Effect of donor orientation on ultrafast intermolecular electron transfer in coumarin-amine systems

    International Nuclear Information System (INIS)

    Singh, P. K.; Nath, S.; Bhasikuttan, A. C.; Kumbhakar, M.; Mohanty, J.; Sarkar, S. K.; Mukherjee, T.; Pal, H.

    2008-01-01

    Effect of donor amine orientation on nondiffusive ultrafast intermolecular electron transfer (ET) reactions in coumarin-amine systems has been investigated using femtosecond fluorescence upconversion measurements. Intermolecular ET from different aromatic and aliphatic amines used as donor solvents to the excited coumarin-151 (C151) acceptor occurs with ultrafast rates such that the shortest fluorescence lifetime component (τ 1 ) is the measure of the fastest ET rate (τ 1 =τ ET fast =(k ET fast ) -1 ), assigned to the C151-amine contact pairs in which amine donors are properly oriented with respect to C151 to maximize the acceptor-donor electronic coupling (V el ). It is interestingly observed that as the amine solvents are diluted by suitable diluents (either keeping solvent dielectric constant similar or with increasing dielectric constant), the τ 1 remains almost in the similar range as long as the amine dilution does not cross a certain critical limit, which in terms of the amine mole fraction (x A ) is found to be ∼0.4 for aromatic amines and ∼0.8 for aliphatic amines. Beyond these dilutions in the two respective cases of the amine systems, the τ 1 values are seen to increase very sharply. The large difference in the critical x A values involving aromatic and aliphatic amine donors has been rationalized in terms of the largely different orientational restrictions for the ET reactions as imposed by the aliphatic (n-type) and aromatic (π-type) nature of the amine donors [A. K. Satpati et al., J. Mol. Struct. 878, 84 (2008)]. Since the highest occupied molecular orbital (HOMO) of the n-type aliphatic amines is mostly centralized at the amino nitrogen, only some specific orientations of these amines with respect to the close-contact acceptor dye [also of π-character; A. K. Satpati et al., J. Mol. Struct. 878, 84 (2008) and E. W. Castner et al., J. Phys. Chem. A 104, 2869 (2000)] can give suitable V el and thus ultrafast ET reaction. In contrary, the

  11. Towards a contemporary, comprehensive scoring system for determining technical outcomes of hybrid percutaneous chronic total occlusion treatment: The RECHARGE score.

    Science.gov (United States)

    Maeremans, Joren; Spratt, James C; Knaapen, Paul; Walsh, Simon; Agostoni, Pierfrancesco; Wilson, William; Avran, Alexandre; Faurie, Benjamin; Bressollette, Erwan; Kayaert, Peter; Bagnall, Alan J; Smith, Dave; McEntegart, Margaret B; Smith, William H T; Kelly, Paul; Irving, John; Smith, Elliot J; Strange, Julian W; Dens, Jo

    2018-02-01

    This study sought to create a contemporary scoring tool to predict technical outcomes of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) from patients treated by hybrid operators with differing experience levels. Current scoring systems need regular updating to cope with the positive evolutions regarding materials, techniques, and outcomes, while at the same time being applicable for a broad range of operators. Clinical and angiographic characteristics from 880 CTO-PCIs included in the REgistry of CrossBoss and Hybrid procedures in FrAnce, the NetheRlands, BelGium and UnitEd Kingdom (RECHARGE) were analyzed by using a derivation and validation set (2:1 ratio). Variables significantly associated with technical failure in the multivariable analysis were incorporated in the score. Subsequently, the discriminatory capacity was assessed and the validation set was used to compare with the J-CTO score and PROGRESS scores. Technical success in the derivation and validation sets was 83% and 85%, respectively. Multivariate analysis identified six parameters associated with technical failure: blunt stump (beta coefficient (b) = 1.014); calcification (b = 0.908); tortuosity ≥45° (b = 0.964); lesion length 20 mm (b = 0.556); diseased distal landing zone (b = 0.794), and previous bypass graft on CTO vessel (b = 0.833). Score variables remained significant after bootstrapping. The RECHARGE score showed better discriminatory capacity in both sets (area-under-the-curve (AUC) = 0.783 and 0.711), compared to the J-CTO (AUC = 0.676) and PROGRESS (AUC = 0.608) scores. The RECHARGE score is a novel, easy-to-use tool for assessing the risk for technical failure in hybrid CTO-PCI and has the potential to perform well for a broad community of operators. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  12. General theory of excitation energy transfer in donor-mediator-acceptor systems.

    Science.gov (United States)

    Kimura, Akihiro

    2009-04-21

    General theory of the excitation energy transfer (EET) in the case of donor-mediator-acceptor system was constructed by using generalized master equation (GME). In this theory, we consider the direct and indirect transitions in the EET consistently. Hence, our theory includes the quantum mechanical interference between the direct and indirect transitions automatically. Memory functions in the GME were expressed by the overlap integrals among the time-dependent emission spectrum of the donor, the absorption spectrum of the mediator, the time-dependent emission spectrum of the mediator, and the absorption spectrum of the acceptor. In the Markov limit of the memory functions, we obtained the rate of EET which consists of three terms due to the direct transition, the indirect transition, and the interference between them. We found that the interference works effectively in the limit of slow thermalization at the intermediate state. The formula of EET rate in this limit was expressed by the convolution of the EET interaction and optical spectra. The interference effect strongly depends on the width of the absorption spectrum of mediator molecule and the energy gap between the donor and the mediator molecules.

  13. Hemophilic arthropathy. A scoring system for magnetic resonance imaging

    International Nuclear Information System (INIS)

    Soler, R.; Rodriguez, E.; Marini, M.; Lopez-Fernandez, F.

    2002-01-01

    The aim of this study was to define a system for scoring hemophilic arthropathy (HA) based on MR findings, providing for objective evaluation of the degree of joint involvement and evolution after on-demand administration of FVIII substitutional therapy or prophylactic treatment. A total of 133 MR examinations (89 basal and 44 during follow-up) were performed in 25 patients. Patients were divided in two groups depending on the therapy received and the length of time that the disease had been evolving at the start of the study. Group I was composed of 10 patients with secondary prophylaxis and group II was composed by 15 treated on demand. T1-weighted and T2*-weighted images performed on a 0.5-T unit were prospectively evaluated. The joint involvement was established on a scale of 0 (no abnormalities), I (minimal amount of hemosiderin), II (large amount of hemosiderin and isolated cartilaginous erosion), III (cartilage destruction, bone erosions, and subchondral cysts) to IV (large internal joint derangement, secondary osteoarthritis and/or ankylosis). At basal MR examination, patients of group I showed no abnormalities (n=28, 75.6%), grade I (n=3), and grade II (n=6) of HA. Patients of group II corresponded to MR grades III (n=21) and IV (n=11) of HA. The MR follow-up showed improvement in three joints of group I and worsening in 5 joints in group I and 2 joints in group II. Early signs of HA were detected in 10 joints with MR imaging but were underestimated on plain radiographs. Advanced degrees of HA were classified as severe under both imaging techniques. Magnetic resonance is the preferred imaging technique to assess HA. The earliest signs of joint damage, detected by MR, are overlooked by plain radiography. The MR scoring system can be used for evaluating HA. Follow-up MR should be performed to evaluate regression or worsening of the abnormalities, primarily in the case of patients with prophylaxis who usually suffer normal or early joint involvement not

  14. Hemophilic arthropathy. A scoring system for magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Soler, R.; Rodriguez, E.; Marini, M. [Department of Radiology, Hospital Juan Canalejo, Coruna (Spain); Lopez-Fernandez, F. [Department of Hematology, Hospital Juan Canalejo, Coruna (Spain)

    2002-04-01

    The aim of this study was to define a system for scoring hemophilic arthropathy (HA) based on MR findings, providing for objective evaluation of the degree of joint involvement and evolution after on-demand administration of FVIII substitutional therapy or prophylactic treatment. A total of 133 MR examinations (89 basal and 44 during follow-up) were performed in 25 patients. Patients were divided in two groups depending on the therapy received and the length of time that the disease had been evolving at the start of the study. Group I was composed of 10 patients with secondary prophylaxis and group II was composed by 15 treated on demand. T1-weighted and T2*-weighted images performed on a 0.5-T unit were prospectively evaluated. The joint involvement was established on a scale of 0 (no abnormalities), I (minimal amount of hemosiderin), II (large amount of hemosiderin and isolated cartilaginous erosion), III (cartilage destruction, bone erosions, and subchondral cysts) to IV (large internal joint derangement, secondary osteoarthritis and/or ankylosis). At basal MR examination, patients of group I showed no abnormalities (n=28, 75.6%), grade I (n=3), and grade II (n=6) of HA. Patients of group II corresponded to MR grades III (n=21) and IV (n=11) of HA. The MR follow-up showed improvement in three joints of group I and worsening in 5 joints in group I and 2 joints in group II. Early signs of HA were detected in 10 joints with MR imaging but were underestimated on plain radiographs. Advanced degrees of HA were classified as severe under both imaging techniques. Magnetic resonance is the preferred imaging technique to assess HA. The earliest signs of joint damage, detected by MR, are overlooked by plain radiography. The MR scoring system can be used for evaluating HA. Follow-up MR should be performed to evaluate regression or worsening of the abnormalities, primarily in the case of patients with prophylaxis who usually suffer normal or early joint involvement not

  15. Reliable scar scoring system to assess photographs of burn patients.

    Science.gov (United States)

    Mecott, Gabriel A; Finnerty, Celeste C; Herndon, David N; Al-Mousawi, Ahmed M; Branski, Ludwik K; Hegde, Sachin; Kraft, Robert; Williams, Felicia N; Maldonado, Susana A; Rivero, Haidy G; Rodriguez-Escobar, Noe; Jeschke, Marc G

    2015-12-01

    Several scar-scoring scales exist to clinically monitor burn scar development and maturation. Although scoring scars through direct clinical examination is ideal, scars must sometimes be scored from photographs. No scar scale currently exists for the latter purpose. We modified a previously described scar scale (Yeong et al., J Burn Care Rehabil 1997) and tested the reliability of this new scale in assessing burn scars from photographs. The new scale consisted of three parameters as follows: scar height, surface appearance, and color mismatch. Each parameter was assigned a score of 1 (best) to 4 (worst), generating a total score of 3-12. Five physicians with burns training scored 120 representative photographs using the original and modified scales. Reliability was analyzed using coefficient of agreement, Cronbach alpha, intraclass correlation coefficient, variance, and coefficient of variance. Analysis of variance was performed using the Kruskal-Wallis test. Color mismatch and scar height scores were validated by analyzing actual height and color differences. The intraclass correlation coefficient, the coefficient of agreement, and Cronbach alpha were higher for the modified scale than those of the original scale. The original scale produced more variance than that in the modified scale. Subanalysis demonstrated that, for all categories, the modified scale had greater correlation and reliability than the original scale. The correlation between color mismatch scores and actual color differences was 0.84 and between scar height scores and actual height was 0.81. The modified scar scale is a simple, reliable, and useful scale for evaluating photographs of burn patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Various scoring systems for predicting mortality in Intensive Care Unit

    African Journals Online (AJOL)

    2015-12-07

    Dec 7, 2015 ... Mortality rate was higher in patients admitted from wards other than surgery ... evaluate the predictability of various severity of illness scores, and ..... Livingston BM, MacKirdy FN, Howie JC, Jones R, Norrie JD. Assessment of.

  17. Bond of donor-acceptor interaction in metal-ligand system with energies of Fermi electrons

    International Nuclear Information System (INIS)

    Vlasov, Yu.V.; Khentov, V.Ya.; Velikanova, L.N.; Semchenko, V.V.

    1993-01-01

    Role of quantum nature of metal (W, Mo and others) in donor-acceptor interaction of metal salicylalaniline - aprotic solvent was discussed. The dependence of dissolution rate and activation energy of donor-acceptor interaction on electron energy was established

  18. Antithrombotic drugs and non-variceal bleeding outcomes and risk scoring systems: comparison of Glasgow Blatchford, Rockall and Charlson scores

    Science.gov (United States)

    Taha, Ali S; McCloskey, Caroline; Craigen, Theresa; Angerson, Wilson J

    2016-01-01

    Objectives Antithrombotic drugs (ATDs) cause non-variceal upper gastrointestinal bleeding (NVUGIB). Risk scoring systems have not been validated in ATD users. We compared Blatchford, Rockall and Charlson scores in predicting outcomes of NVUGIB in ATD users and controls. Methods A total of 2071 patients with NVUGIB were grouped into ATD users (n=851) and controls (n=1220) in a single-centre retrospective analysis. Outcomes included duration of hospital admission, the need for blood transfusion, rebleeding requiring surgery and 30-day mortality. Results Duration of admission correlated with all scores in controls, but correlations were significantly weaker in ATD users. Rank correlation coefficients in control versus ATD: 0.45 vs 0.20 for Blatchford; 0.48 vs 0.32 for Rockall and 0.42 vs 0.26 for Charlson (all p<0.001). The need for transfusion was best predicted by Blatchford (p<0.001 vs Rockall and Charlson in both ATD users and controls), but all scores performed less well in ATD users. Area under the receiver operation characteristic curve (AUC) in control versus ATD: 0.90 vs 0.85 for Blatchford; 0.77 vs 0.61 for Rockall and 0.69 vs 0.56 for Charlson (all p<0.005). In predicting surgery, Rockall performed best; while mortality was best predicted by Charlson with lower AUCs in ATD patients than controls (p<0.05). Stratification showed the scores' performance to be age-dependent. Conclusions Blatchford score was the strongest predictor of transfusion, Rockall's had the strongest correlation with duration of admission and with rebleeding requiring surgery and Charlson was best in predicting 30-day mortality. Modifications of these systems should be explored to improve their efficiency in ATD users. PMID:28839866

  19. Modified Framingham Risk Factor Score for Systemic Lupus Erythematosus.

    Science.gov (United States)

    Urowitz, Murray B; Ibañez, Dominique; Su, Jiandong; Gladman, Dafna D

    2016-05-01

    The traditional Framingham Risk Factor Score (FRS) underestimates the risk for coronary artery disease (CAD) in patients with systemic lupus erythematosus (SLE). We aimed to determine whether an adjustment to the FRS would more accurately reflect the higher prevalence of CAD among patients with SLE. Patients with SLE without a previous history of CAD or diabetes followed regularly at the University of Toronto Lupus Clinic were included. A modified FRS (mFRS) was calculated by multiplying the items by 1.5, 2, 3, or 4. In the first part of the study, using one-third of all eligible patients, we evaluated the sensitivity and specificity of the FRS and the different multipliers for the mFRS. In the second part of the study, using the remaining 2/3 of the eligible patients, we compared the predictive ability of the FRS to the mFRS. In the third part of the study, we assessed the prediction for CAD in a time-dependent analysis of the FRS and mFRS. There were 905 women (89.3%) with a total of 95 CAD events included. In part 1, we determined that a multiplier of 2 provided the best combination of sensitivity and specificity. In part 2, 2.4% of the patients were classified as moderate/high risk based on the classic FRS and 17.3% using the 2FRS (the FRS with a multiplier of 2). In part 3, a time-dependent covariate analysis for the prediction of the first CAD event revealed an HR of 3.22 (p = 0.07) for the classic FRS and 4.37 (p mFRS in which each item is multiplied by 2 more accurately predicts CAD in patients with SLE.

  20. Automated Quantification of the Landing Error Scoring System With a Markerless Motion-Capture System.

    Science.gov (United States)

    Mauntel, Timothy C; Padua, Darin A; Stanley, Laura E; Frank, Barnett S; DiStefano, Lindsay J; Peck, Karen Y; Cameron, Kenneth L; Marshall, Stephen W

    2017-11-01

      The Landing Error Scoring System (LESS) can be used to identify individuals with an elevated risk of lower extremity injury. The limitation of the LESS is that raters identify movement errors from video replay, which is time-consuming and, therefore, may limit its use by clinicians. A markerless motion-capture system may be capable of automating LESS scoring, thereby removing this obstacle.   To determine the reliability of an automated markerless motion-capture system for scoring the LESS.   Cross-sectional study.   United States Military Academy.   A total of 57 healthy, physically active individuals (47 men, 10 women; age = 18.6 ± 0.6 years, height = 174.5 ± 6.7 cm, mass = 75.9 ± 9.2 kg).   Participants completed 3 jump-landing trials that were recorded by standard video cameras and a depth camera. Their movement quality was evaluated by expert LESS raters (standard video recording) using the LESS rubric and by software that automates LESS scoring (depth-camera data). We recorded an error for a LESS item if it was present on at least 2 of 3 jump-landing trials. We calculated κ statistics, prevalence- and bias-adjusted κ (PABAK) statistics, and percentage agreement for each LESS item. Interrater reliability was evaluated between the 2 expert rater scores and between a consensus expert score and the markerless motion-capture system score.   We observed reliability between the 2 expert LESS raters (average κ = 0.45 ± 0.35, average PABAK = 0.67 ± 0.34; percentage agreement = 0.83 ± 0.17). The markerless motion-capture system had similar reliability with consensus expert scores (average κ = 0.48 ± 0.40, average PABAK = 0.71 ± 0.27; percentage agreement = 0.85 ± 0.14). However, reliability was poor for 5 LESS items in both LESS score comparisons.   A markerless motion-capture system had the same level of reliability as expert LESS raters, suggesting that an automated system can accurately assess movement. Therefore, clinicians can use

  1. Renal Transplants from Older Deceased Donors: Use of Preimplantation Biopsy and Differential Allocation to Dual or Single Kidney Transplant according to Histological Score Has No Advantages over Allocation to Single Kidney Transplant by Simple Clinical Indication

    Directory of Open Access Journals (Sweden)

    Costanza Casati

    2018-01-01

    Full Text Available Background. Grafts from elderly donors (ECD are increasingly allocated to single (SKT or dual (DKT kidney transplantation according to biopsy score. Indications and benefits of either procedure lack universal agreement. Methods. A total of 302 ECD-transplants in period from Jan 1, 2000, to Dec 31, 2015, were allocated to SKT (SKTpre on clinical grounds alone (before Dec 2010, pre-DKT era, n=170 or according to a clinical-histological protocol (after Dec 2010, DKT era, n=132 to DKT (n=48, SKT biopsy-based protocol (“high-risk”, SKThr, n=51, or SKT clinically based protocol (“low-risk”, SKTlr, n=33. Graft and patient survival were compared between the two periods and between different transplant categories. Results. Graft and overall survival in recipients from ECD in pre-DKT and DKT era did not differ (5-year graft survival 87.7% and 84.2%, resp.; equal survival in the 2 ECD periods was shown in both donor age ranges of 60–69 and >70-years, and in low-risk or high-risk ECD categories. Within the DKT protocol SKThr showed worst graft and overall survival in the 60–69 donor age range; DKT did not result in significantly better outcome than SKT from ECD in either era. One-year posttransplant creatinine clearance in recipients did not differ between any ECD transplant category. At 3 and 5 years after transplantation there were significantly higher total dialysis-free recipient life years from an equal donor number in the pre-DKT era than in the DKT protocol. Conclusions. Use of a biopsy-based protocol to allocate grafts from aged donors to SKT or DKT did not result in better short term graft survival than a clinically based protocol with allocation only to SKT and reduced overall recipient dialysis-free life years in time.

  2. Renal Transplants from Older Deceased Donors: Use of Preimplantation Biopsy and Differential Allocation to Dual or Single Kidney Transplant according to Histological Score Has No Advantages over Allocation to Single Kidney Transplant by Simple Clinical Indication.

    Science.gov (United States)

    Casati, Costanza; Colombo, Valeriana Giuseppina; Perrino, Marialuisa; Rossetti, Ornella Marina; Querques, Marialuisa; Giacomoni, Alessandro; Binaggia, Agnese; Colussi, Giacomo

    2018-01-01

    Grafts from elderly donors (ECD) are increasingly allocated to single (SKT) or dual (DKT) kidney transplantation according to biopsy score. Indications and benefits of either procedure lack universal agreement. A total of 302 ECD-transplants in period from Jan 1, 2000, to Dec 31, 2015, were allocated to SKT (SKT pre ) on clinical grounds alone (before Dec 2010, pre-DKT era, n = 170) or according to a clinical-histological protocol (after Dec 2010, DKT era, n = 132) to DKT ( n = 48), SKT biopsy-based protocol ("high-risk", SKT hr , n = 51), or SKT clinically based protocol ("low-risk", SKT lr , n = 33). Graft and patient survival were compared between the two periods and between different transplant categories. Graft and overall survival in recipients from ECD in pre-DKT and DKT era did not differ (5-year graft survival 87.7% and 84.2%, resp.); equal survival in the 2 ECD periods was shown in both donor age ranges of 60-69 and >70-years, and in low-risk or high-risk ECD categories. Within the DKT protocol SKT hr showed worst graft and overall survival in the 60-69 donor age range; DKT did not result in significantly better outcome than SKT from ECD in either era. One-year posttransplant creatinine clearance in recipients did not differ between any ECD transplant category. At 3 and 5 years after transplantation there were significantly higher total dialysis-free recipient life years from an equal donor number in the pre-DKT era than in the DKT protocol. Use of a biopsy-based protocol to allocate grafts from aged donors to SKT or DKT did not result in better short term graft survival than a clinically based protocol with allocation only to SKT and reduced overall recipient dialysis-free life years in time.

  3. The R.I.R.S. scoring system: An innovative scoring system for predicting stone-free rate following retrograde intrarenal surgery.

    Science.gov (United States)

    Xiao, Yinglong; Li, Deng; Chen, Lei; Xu, Yaoting; Zhang, Dingguo; Shao, Yi; Lu, Jun

    2017-11-21

    To establish and internally validate an innovative R.I.R.S. scoring system that allows urologists to preoperatively estimate the stone-free rate (SFR) after retrograde intrarenal surgery (RIRS). This study included 382 eligible samples from a total 573 patients who underwent RIRS from January 2014 to December 2016. Four reproducible factors in the R.I.R.S. scoring system, including renal stone density, inferior pole stone, renal infundibular length and stone burden, were measured based on preoperative computed tomography of urography to evaluate the possibility of stone clearance after RIRS. The median cumulative diameter of the stones was 14 mm, and the interquartile range was 10 to 21. The SFR on postoperative day 1 in the present cohort was 61.5% (235 of 382), and the final SFR after 1 month was 73.6% (281 of 382). We established an innovative scoring system to evaluate SFR after RIRS using four preoperative characteristics. The range of the R.I.R.S. scoring system was 4 to 10. The overall score showed a great significance of stone-free status (p R.I.R.S. scoring system was 0.904. The R.I.R.S. scoring system is associated with SFR after RIRS. This innovative scoring system can preoperatively assess treatment success after intrarenal surgery and can be used for preoperative surgical arrangement and comparisons of outcomes among different centers and within a center over time.

  4. Magnetic field effects on geminate reactions. Study of anthraquinone - hydrogen donors systems

    International Nuclear Information System (INIS)

    Vidal, Marie-Helene

    1987-01-01

    This study is devoted to magnetic field effects on chemical reactions which involve a radical pair with correlated spins (radical in a 'cage'). In the first part, the radical pair theory is described: mechanisms of singlet-triplet mixing, the different interactions inside the pair and a quantum mechanical treatment of the radical pair. The details of the experimental method (nanosecond laser flash photolysis) are reported in the second part. In the third part are shown experimental results obtained on Anthraquinone (AQ) - Hydrogen donors systems: - There is no magnetic field effect in homogeneous solution even at a high viscosity. The absorption spectra of the different reaction intermediates are obtained. - However a magnetic field effect is put forward when AQ is introduced in SDS micelles which are hydrogen donors. The absorption spectrum of the AQH · . semi-quinone radical in 'cage' is shown and a mechanism is proposed for its disappearance to generate the AQH-S and AQH 2 species. - The addition of 9, 10 Dihydroanthracene (DH2) inside the micelle near AQ induces an increase of the magnetic field effect by creation of (AQH · . - DH · . ) pairs which diffuse slowly. - Fixed radical pairs in a protein matrix were studied in reaction centers of photosynthetic bacteria: in that case, the half effect field is shifted to low fields when compared to the previously described systems. (author) [fr

  5. Computer-Assisted Automated Scoring of Polysomnograms Using the Somnolyzer System.

    Science.gov (United States)

    Punjabi, Naresh M; Shifa, Naima; Dorffner, Georg; Patil, Susheel; Pien, Grace; Aurora, Rashmi N

    2015-10-01

    Manual scoring of polysomnograms is a time-consuming and tedious process. To expedite the scoring of polysomnograms, several computerized algorithms for automated scoring have been developed. The overarching goal of this study was to determine the validity of the Somnolyzer system, an automated system for scoring polysomnograms. The analysis sample comprised of 97 sleep studies. Each polysomnogram was manually scored by certified technologists from four sleep laboratories and concurrently subjected to automated scoring by the Somnolyzer system. Agreement between manual and automated scoring was examined. Sleep staging and scoring of disordered breathing events was conducted using the 2007 American Academy of Sleep Medicine criteria. Clinical sleep laboratories. A high degree of agreement was noted between manual and automated scoring of the apnea-hypopnea index (AHI). The average correlation between the manually scored AHI across the four clinical sites was 0.92 (95% confidence interval: 0.90-0.93). Similarly, the average correlation between the manual and Somnolyzer-scored AHI values was 0.93 (95% confidence interval: 0.91-0.96). Thus, interscorer correlation between the manually scored results was no different than that derived from manual and automated scoring. Substantial concordance in the arousal index, total sleep time, and sleep efficiency between manual and automated scoring was also observed. In contrast, differences were noted between manually and automated scored percentages of sleep stages N1, N2, and N3. Automated analysis of polysomnograms using the Somnolyzer system provides results that are comparable to manual scoring for commonly used metrics in sleep medicine. Although differences exist between manual versus automated scoring for specific sleep stages, the level of agreement between manual and automated scoring is not significantly different than that between any two human scorers. In light of the burden associated with manual scoring, automated

  6. A stage is a stage is a stage: a direct comparison of two scoring systems.

    Science.gov (United States)

    Dawson, Theo L

    2003-09-01

    L. Kohlberg (1969) argued that his moral stages captured a developmental sequence specific to the moral domain. To explore that contention, the author compared stage assignments obtained with the Standard Issue Scoring System (A. Colby & L. Kohlberg, 1987a, 1987b) and those obtained with a generalized content-independent stage-scoring system called the Hierarchical Complexity Scoring System (T. L. Dawson, 2002a), on 637 moral judgment interviews (participants' ages ranged from 5 to 86 years). The correlation between stage scores produced with the 2 systems was .88. Although standard issue scoring and hierarchical complexity scoring often awarded different scores up to Kohlberg's Moral Stage 2/3, from his Moral Stage 3 onward, scores awarded with the two systems predominantly agreed. The author explores the implications for developmental research.

  7. Similar predictions of etravirine sensitivity regardless of genotypic testing method used: comparison of available scoring systems.

    Science.gov (United States)

    Vingerhoets, Johan; Nijs, Steven; Tambuyzer, Lotke; Hoogstoel, Annemie; Anderson, David; Picchio, Gaston

    2012-01-01

    The aims of this study were to compare various genotypic scoring systems commonly used to predict virological outcome to etravirine, and examine their concordance with etravirine phenotypic susceptibility. Six etravirine genotypic scoring systems were assessed: Tibotec 2010 (based on 20 mutations; TBT 20), Monogram, Stanford HIVdb, ANRS, Rega (based on 37, 30, 27 and 49 mutations, respectively) and virco(®)TYPE HIV-1 (predicted fold change based on genotype). Samples from treatment-experienced patients who participated in the DUET trials and with both genotypic and phenotypic data (n=403) were assessed using each scoring system. Results were retrospectively correlated with virological response in DUET. κ coefficients were calculated to estimate the degree of correlation between the different scoring systems. Correlation between the five scoring systems and the TBT 20 system was approximately 90%. Virological response by etravirine susceptibility was comparable regardless of which scoring system was utilized, with 70-74% of DUET patients determined as susceptible to etravirine by the different scoring systems achieving plasma viral load <50 HIV-1 RNA copies/ml. In samples classed as phenotypically susceptible to etravirine (fold change in 50% effective concentration ≤3), correlations with genotypic score were consistently high across scoring systems (≥70%). In general, the etravirine genotypic scoring systems produced similar results, and genotype-phenotype concordance was high. As such, phenotypic interpretations, and in their absence all genotypic scoring systems investigated, may be used to reliably predict the activity of etravirine.

  8. Scoring system in cirrhotics due to viral hepatitis

    International Nuclear Information System (INIS)

    Abbasi, A.; Bhutto, A.R.; Butt, N.; Lal, K.; Munir, S.M.

    2012-01-01

    Objective: To determine the association of serum cholesterol levels with Child-Pugh class in patients with decompensated chronic liver disease due to viral hepatitis. Methodology: Consecutive patients attending outpatient department or admitted in medical unit III were eligible if they had a diagnosis of cirrhosis secondary to viral hepatitis. Patients were excluded if alcoholic, diabetic, hypertensive, or with non-alcoholic fatty liver disease, autoimmune, metabolic, cardiovascular, cerebrovascular or kidney diseases and recent use of lipid-regulating drugs. Serum lipid profile was determined after an overnight fast of 12 hours. On the basis of serum total cholesterol, patients were divided into four groups; Group I with serum total cholesterol = 100 mg/dl, Group II with level of 101-150 mg/dl, Group III with level of 151-200 mg/dl and Group IV with serum total cholesterol level of > 200 mg/dl. Hepatic dysfunction was categorized according to Child-Pugh scoring system. Chi-square and Spearman's correlation testing with p < 0.05 was accepted as significant. Results: One hundred and fourteen patients met the inclusion criteria with a mean age of 40.32 +- 13.59 years. Among these 32 were females (28.1%) while 82 were males (71.9%). According to Child-Pugh class; 34 patients (29.8%) presented with Child-Pugh class A, 34 (29.8%) in class B and 46 (40.4%) were in class C. Serum cholesterol (total) and triglycerides had significant association with Child-Pugh class (p = 0.0001 and p = 0.004 respectively) suggesting that as severity of liver dysfunction increases; serum cholesterol and triglycerides levels decrease. Results also revealed that males were significantly more hypocholesterolemic than females (p = 0.006). Conclusion: Hypocholesterolemia is a common finding in decompensated chronic liver disease and has got significant association with Child-Pugh class. It may increase the reliability of Child-Pugh classification in assessment of severity and prognosis in

  9. 76 FR 10050 - Changes to the Public Housing Assessment System (PHAS): Management Operations Scoring Notice

    Science.gov (United States)

    2011-02-23

    ... Housing Assessment System (PHAS): Management Operations Scoring Notice SUMMARY: This notice provides... issuing scores under the management operations indicator of the Public Housing Assessment System (PHAS... notice is to provide additional information about the scoring process for the PHAS management operations...

  10. Various scoring systems for predicting mortality in Intensive Care Unit

    African Journals Online (AJOL)

    Age, gender, body weight, initial diagnosis, clinic of referral, intubation, comorbidities, APACHE II, APACHE IV, Glasgow coma scale, SAPS III scores, length of hospitalization before referral to ICU, length of stay in ICU, mechanical ventilation were recorded. Results: Most of the patients (54.6%) were consulted from ...

  11. Different Clinical Features and Lower Scores in Clinical Scoring Systems for Appendicitis in Preschool Children: Comparison with School Age Onset

    OpenAIRE

    Song, Chun Woo; Kang, Joon Won; Kim, Jae Young

    2018-01-01

    Purpose To clarify the clinical features of appendicitis in preschool children and to explore clinical appendicitis scoring systems in this age group. Methods We retrospectively collected data on 142 children, aged 10 years or younger, with confirmed diagnosis of appendicitis based on surgical and pathologic findings. Enrolled subjects were divided into two groups: Group 1 (preschool children aged ≤5 years, n=41) and Group 2 (school children aged >5 to ≤10 years, n=101). Data analyzed include...

  12. Dissipative exciton transfer in donor-bridge-acceptor systems: numerical renormalization group calculation of equilibrium properties

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, Sabine [Theoretische Physik III, Elektronische Korrelationen und Magnetismus, Universitaet Augsburg, 86135 Augsburg (Germany); Tong, Ning-Hua [Institut fuer Theorie der Kondensierten Materie, Universitaet Karlsruhe, 76128 Karlsruhe (Germany); Bulla, Ralf [Theoretische Physik III, Elektronische Korrelationen und Magnetismus, Universitaet Augsburg, 86135 Augsburg (Germany)

    2006-07-05

    We present a detailed model study of exciton transfer processes in donor-bridge-acceptor (DBA) systems. Using a model which includes the intermolecular Coulomb interaction and the coupling to a dissipative environment we calculate the phase diagram, the absorption spectrum as well as dynamic equilibrium properties with the numerical renormalization group. This method is non-perturbative and therefore allows one to cover the full parameter space, especially the case when the intermolecular Coulomb interaction is of the same order as the coupling to the environment and perturbation theory cannot be applied. For DBA systems with up to six sites we found a transition to the localized phase (self-trapping) depending on the coupling to the dissipative environment. We discuss various criteria which favour delocalized exciton transfer.

  13. Dissipative exciton transfer in donor-bridge-acceptor systems: numerical renormalization group calculation of equilibrium properties.

    Science.gov (United States)

    Tornow, Sabine; Tong, Ning-Hua; Bulla, Ralf

    2006-07-05

    We present a detailed model study of exciton transfer processes in donor-bridge-acceptor (DBA) systems. Using a model which includes the intermolecular Coulomb interaction and the coupling to a dissipative environment we calculate the phase diagram, the absorption spectrum as well as dynamic equilibrium properties with the numerical renormalization group. This method is non-perturbative and therefore allows one to cover the full parameter space, especially the case when the intermolecular Coulomb interaction is of the same order as the coupling to the environment and perturbation theory cannot be applied. For DBA systems with up to six sites we found a transition to the localized phase (self-trapping) depending on the coupling to the dissipative environment. We discuss various criteria which favour delocalized exciton transfer.

  14. Introducing the HOPE (Hypospadias Objective Penile Evaluation)-score : A validation study of an objective scoring system for evaluating cosmetic appearance in hypospadias patients

    NARCIS (Netherlands)

    van der Toorn, Fred; de Jong, Tom P. V. M.; de Gier, Robert P. E.; Callewaert, Piet R. H.; van der Horst, Eric H. J. R.; Steffens, Martijn G.; Hoebeke, Piet; Nijman, Rien J. M.; Bush, Nicol C.; Wolffenbuttel, Katja P.; van den Heijkant, Marleen M. C.; van Capelle, Jan-Willem; Wildhagen, Mark; Timman, Reinier; van Busschbach, Jan J. V.

    2013-01-01

    Objective: To determine the reliability and internal validity of the Hypospadias Objective Penile Evaluation (HOPE)-score, a newly developed scoring system assessing the cosmetic outcome in hypospadias. Patients and methods: The HOPE scoring system incorporates all surgically-correctable items:

  15. The rat whole embryo culture assay using the Dysmorphology Score system.

    Science.gov (United States)

    Zhang, Cindy; Panzica-Kelly, Julie; Augustine-Rauch, Karen

    2013-01-01

    The rat whole embryo culture (WEC) system has been used extensively for characterizing teratogenic properties of test chemicals. In this chapter, we describe the methodology for culturing rat embryos as well as a new morphological score system, the Dysmorphology Score (DMS) system for assessing morphology of mid gestation (gestational day 11) rat embryos. In contrast to the developmental stage focused scoring associated with the Brown and Fabro score system, this new score system assesses the respective degree of severity of dysmorphology, which delineates normal from abnormal morphology of specific embryonic structures and organ systems. This score system generates an approach that allows rapid identification and quantification of adverse developmental findings, making it conducive for characterization of compounds for teratogenic properties and screening activities.

  16. 76 FR 20366 - Changes to the Public Housing Assessment System (PHAS): Management Operations Scoring Notice

    Science.gov (United States)

    2011-04-12

    ... Housing Assessment System (PHAS): Management Operations Scoring Notice AGENCY: Office of the Assistant... Management Operations interim scoring notice. The document inadvertently omitted a word with respect to the... INFORMATION: I. Background The proposed management operations scoring information was published on August 21...

  17. The longitudinal reliability and responsiveness of the OMERACT Hand Osteoarthritis Magnetic Resonance Imaging Scoring System (HOAMRIS)

    DEFF Research Database (Denmark)

    Haugen, Ida K.; Eshed, Iris; Gandjbakhch, Frederique

    2015-01-01

    Objective. To evaluate the interreader reliability of change scores and the responsiveness of the OMERACT Hand Osteoarthritis (OA) Magnetic Resonance Image (MRI) Scoring System (HOAMRIS). Methods. Paired MRI (baseline and 5-yr followup) from 20 patients with hand OA were scored with known time se...

  18. Clicker Score Trajectories and Concept Inventory Scores as Predictors for Early Warning Systems for Large STEM Classes

    Science.gov (United States)

    Lee, Un Jung; Sbeglia, Gena C.; Ha, Minsu; Finch, Stephen J.; Nehm, Ross H.

    2015-12-01

    Increasing the retention of STEM (science, technology, engineering, and mathematics) majors has recently emerged as a national priority in undergraduate education. Since poor performance in large introductory science and math courses is one significant factor in STEM dropout, early detection of struggling students is needed. Technology-supported "early warning systems" (EWSs) are being developed to meet these needs. Our study explores the utility of two commonly collected data sources—pre-course concept inventory scores and longitudinal clicker scores—for use in EWS, specifically, in determining the time points at which robust predictions of student success can first be established. The pre-course diagnostic assessments, administered to 287 students, included two concept inventories and one attitude assessment. Clicker question scores were also obtained for each of the 37 class sessions. Additionally, student characteristics (sex, ethnicity, and English facility) were gathered in a survey. Our analyses revealed that all variables were predictive of final grades. The correlation of the first 3 weeks of clicker scores with final grades was 0.53, suggesting that this set of variables could be used in an EWS starting at the third week. We also used group-based trajectory models to assess whether trajectory patterns were homogeneous in the class. The trajectory analysis identified three distinct clicker performance patterns that were also significant predictors of final grade. Trajectory analyses of clicker scores, student characteristics, and pre-course diagnostic assessment appear to be valuable data sources for EWS, although further studies in a diversity of instructional contexts are warranted.

  19. Correlation of Head Impacts to Change in Balance Error Scoring System Scores in Division I Men's Lacrosse Players.

    Science.gov (United States)

    Miyashita, Theresa L; Diakogeorgiou, Eleni; Marrie, Kaitlyn

    Investigation into the effect of cumulative subconcussive head impacts has yielded various results in the literature, with many supporting a link to neurological deficits. Little research has been conducted on men's lacrosse and associated balance deficits from head impacts. (1) Athletes will commit more errors on the postseason Balance Error Scoring System (BESS) test. (2) There will be a positive correlation to change in BESS scores and head impact exposure data. Prospective longitudinal study. Level 3. Thirty-four Division I men's lacrosse players (age, 19.59 ± 1.42 years) wore helmets instrumented with a sensor to collect head impact exposure data over the course of a competitive season. Players completed a BESS test at the start and end of the competitive season. The number of errors from pre- to postseason increased during the double-leg stance on foam ( P impacts sustained over the course of 1 lacrosse season, as measured by average linear acceleration, head injury criteria, and Gadd Severity Index scores. If there is microtrauma to the vestibular system due to repetitive subconcussive impacts, only an assessment that highly stresses the vestibular system may be able to detect these changes. Cumulative subconcussive impacts may result in neurocognitive dysfunction, including balance deficits, which are associated with an increased risk for injury. The development of a strategy to reduce total number of head impacts may curb the associated sequelae. Incorporation of a modified BESS test, firm surface only, may not be recommended as it may not detect changes due to repetitive impacts over the course of a competitive season.

  20. Development and validation of the International Hidradenitis Suppurativa Severity Score System (IHS4), a novel dynamic scoring system to assess HS severity

    DEFF Research Database (Denmark)

    Zouboulis, C C; Tzellos, T; Kyrgidis, A

    2017-01-01

    BACKGROUND: A validated tool for the dynamic severity assessment of hidradenitis suppurativa/acne inversa (HS) is lacking. OBJECTIVES: To develop and validate a novel dynamic scoring system to assess the severity of HS. METHODS: A Delphi voting procedure was conducted among the members......, as well as examination for correlation (Spearman's rho) and agreement (Cohen's kappa) with existing scores, were engaged to recognize the variables for a new International HS4 (IHS4) that was established by a second Delphi round. RESULTS: Consensus HS4 was based on number of skin lesions, number of skin....... Three candidate scores were presented to the second Delphi round. The resulting IHS4 score is arrived at by the number of nodules (multiplied by 1) plus the number of abscesses (multiplied by 2) plus the number of draining tunnels (multiplied by 4). A total score of 3 or less signifies mild, 4...

  1. Donor Tracker: An Innovative Real-Time Tracking System for Blood ...

    African Journals Online (AJOL)

    In this paper, we explore the possibility of using location-aware computing to track blood donors in Mauritius and locate the nearest donor in cases of emergencies and whenever fresh blood is ... Keywords: Context-awareness, location-awareness, mobile and ubiquitous computing, location sensing technique, real-time.

  2. Predictive value of seven preoperative prognostic scoring systems for spinal metastases.

    Science.gov (United States)

    Leithner, Andreas; Radl, Roman; Gruber, Gerald; Hochegger, Markus; Leithner, Katharina; Welkerling, Heike; Rehak, Peter; Windhager, Reinhard

    2008-11-01

    Predicting prognosis is the key factor in selecting the proper treatment modality for patients with spinal metastases. Therefore, various assessment systems have been designed in order to provide a basis for deciding the course of treatment. Such systems have been proposed by Tokuhashi, Sioutos, Tomita, Van der Linden, and Bauer. The scores differ greatly in the kind of parameters assessed. The aim of this study was to evaluate the prognostic value of each score. Eight parameters were assessed for 69 patients (37 male, 32 female): location, general condition, number of extraspinal bone metastases, number of spinal metastases, visceral metastases, primary tumour, severity of spinal cord palsy, and pathological fracture. Scores according to Tokuhashi (original and revised), Sioutos, Tomita, Van der Linden, and Bauer were assessed as well as a modified Bauer score without scoring for pathologic fracture. Nineteen patients were still alive as of September 2006 with a minimum follow-up of 12 months. All other patients died after a mean period of 17 months after operation. The mean overall survival period was only 3 months for lung cancer, followed by prostate (7 months), kidney (23 months), breast (35 months), and multiple myeloma (51 months). At univariate survival analysis, primary tumour and visceral metastases were significant parameters, while Karnofsky score was only significant in the group including myeloma patients. In multivariate analysis of all seven parameters assessed, primary tumour and visceral metastases were the only significant parameters. Of all seven scoring systems, the original Bauer score and a Bauer score without scoring for pathologic fracture had the best association with survival (P < 0.001). The data of the present study emphasize that the original Bauer score and a modified Bauer score without scoring for pathologic fracture seem to be practicable and highly predictive preoperative scoring systems for patients with spinal metastases

  3. SOME ASPECTS OF IMMUNE SYSTEM FUNCTIONING IN HEALTHY DONORS SUBJECTED TO XENOGENOUS EXPOSURE

    Directory of Open Access Journals (Sweden)

    O. O. Obukhova

    2006-01-01

    Full Text Available Abstract. In present work, we studied some interrelations between tobacco smoking and the processes of immune system stimulation in healthy blood donors. In our opinion, this issue is especially important for the big industrial center, with rather strong antigenic exposure of the organism. The levels of circulating immune complexes (CIC were used as a marker index which reflects specific antigen-antibody interactions during inflammation. According to the results obtained, the majority of persons who have high CIC levels were tobacco smokers (53.76%. Moreover, the percentage of persons with high CIC content, like as the mean values of this index is increased proportionally to the duration of smoking. A mixture of tobacco smoke components seems to exert direct toxic effect upon various compartments of the immune system and causes local irritation of bronchial tree, thus producing local and systemic inflammatory reaction. It is, possibly, an additional factor which determines activation of immune system, with a background of adverse antropogenic exposures typical to industrial centers. The data obtained allow us to affirm a toxic action of tobacco smoke upon the organism of smokers, with development of inflammatory reactions that are displayed as increased CIC levels at preclinical stage.

  4. Towards a global system of vigilance and surveillance in unrelated donors of haematopoietic progenitor cells for transplantation.

    Science.gov (United States)

    Shaw, B E; Chapman, J; Fechter, M; Foeken, L; Greinix, H; Hwang, W; Phillips-Johnson, L; Korhonen, M; Lindberg, B; Navarro, W H; Szer, J

    2013-11-01

    Safety of living donors is critical to the success of blood, tissue and organ transplantation. Structured and robust vigilance and surveillance systems exist as part of some national entities, but historically no global systems are in place to ensure conformity, harmonisation and the recognition of rare adverse events (AEs). The World Health Assembly has recently resolved to require AE/reaction (AE/R) reporting both nationally and globally. The World Marrow Donor Association (WMDA) is an international organisation promoting the safety of unrelated donors and progenitor cell products for use in haematopoietic progenitor cell (HPC) transplantation. To address this issue, we established a system for collecting, collating, analysing, distributing and reacting to serious adverse events and reactions (SAE/R) in unrelated HPC donors. The WMDA successfully instituted this reporting system with 203 SAE/R reported in 2011. The committee generated two rapid reports, reacting to specific SAE/R, resulting in practice changing policies. The system has a robust governance structure, formal feedback to the WMDA membership and transparent information flows to other agencies, specialist physicians and transplant programs and the general public.

  5. Resonant and non-resonant components of the rate of a population transfer in hybrid donor-acceptor systems

    Czech Academy of Sciences Publication Activity Database

    Menšík, Miroslav; Král, Karel

    2013-01-01

    Roč. 5, č. 6 (2013), s. 565-568 ISSN 2164-6627 R&D Projects: GA MŠk(CZ) OC10007; GA MŠk LH12186; GA ČR(CZ) GAP205/10/2280 Institutional support: RVO:61389013 ; RVO:68378271 Keywords : energy transfer * hybrid donor-acceptor system Subject RIV: BM - Solid Matter Physics ; Magnetism

  6. The value of international prostate symptom scoring system in the ...

    African Journals Online (AJOL)

    IPSS) system in management of patients with benign prostatic hyperplasia (BPH) in Jos, Nigeria. Materials and Methods: This was a prospective study of 104 newly diagnosed patients with BPH from June 2006 to July 2007. Patients' symptoms ...

  7. 78 FR 76160 - Public Housing Assessment System (PHAS) Capital Fund Interim Scoring Notice: Reinstitution of...

    Science.gov (United States)

    2013-12-16

    ... System (PHAS) Capital Fund Interim Scoring Notice: Reinstitution of Five Points for Occupancy Sub... intended to help lessen the impact of decreases in funding in recent appropriations acts. Adding automatic... to adjust their systems and procedures to the new scoring regime. As a result of automatic across-the...

  8. An Evaluation of the IntelliMetric[SM] Essay Scoring System

    Science.gov (United States)

    Rudner, Lawrence M.; Garcia, Veronica; Welch, Catherine

    2006-01-01

    This report provides a two-part evaluation of the IntelliMetric[SM] automated essay scoring system based on its performance scoring essays from the Analytic Writing Assessment of the Graduate Management Admission Test[TM] (GMAT[TM]). The IntelliMetric system performance is first compared to that of individual human raters, a Bayesian system…

  9. Validation of the Rockall risk scoring system in upper gastrointestinal bleeding

    NARCIS (Netherlands)

    Vreeburg, E. M.; Terwee, C. B.; Snel, P.; Rauws, E. A.; Bartelsman, J. F.; Meulen, J. H.; Tytgat, G. N.

    1999-01-01

    Several scoring systems have been developed to predict the risk of rebleeding or death in patients with upper gastrointestinal bleeding (UGIB). These risk scoring systems have not been validated in a new patient population outside the clinical context of the original study. To assess internal and

  10. The Reliability and Structure of the Classroom Assessment Scoring System in German Pre-Schools

    Science.gov (United States)

    Stuck, Andrea; Kammermeyer, Gisela; Roux, Susanna

    2016-01-01

    This study examined the reliability and structure of the Classroom Assessment Scoring System (CLASS; Pianta, R. C., K. M. La Paro, and B. K. Hamre. 2008. "Classroom Assessment Scoring System. Manual Pre-K." Baltimore, MD: Brookes) and the quality of interactional processes in a German pre-school setting, drawing on a sample of 390…

  11. Progress Scored in Management Information System at CAS

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ CAS initiative to upgrade its management information system (MIS) is making significant progress. Recently, 116 CAS subordinates have completed their online trial operation of a MIS project at the Academy, called Academia Resource Planning (ARP), marking an important phased achievement of the initiative.

  12. A new scoring system for predicting survival in patients with non-small cell lung cancer

    International Nuclear Information System (INIS)

    Schild, Steven E; Tan, Angelina D; Wampfler, Jason A; Ross, Helen J; Yang, Ping; Sloan, Jeff A

    2015-01-01

    This analysis was performed to create a scoring system to estimate the survival of patients with non-small cell lung cancer (NSCLC). Data from 1274 NSCLC patients were analyzed to create and validate a scoring system. Univariate (UV) and multivariate (MV) Cox models were used to evaluate the prognostic importance of each baseline factor. Prognostic factors that were significant on both UV and MV analyses were used to develop the score. These included quality of life, age, performance status, primary tumor diameter, nodal status, distant metastases, and smoking cessation. The score for each factor was determined by dividing the 5-year survival rate (%) by 10 and summing these scores to form a total score. MV models and the score were validated using bootstrapping with 1000 iterations from the original samples. The score for each prognostic factor ranged from 1 to 7 points with higher scores reflective of better survival. Total scores (sum of the scores from each independent prognostic factor) of 32–37 correlated with a 5-year survival of 8.3% (95% CI = 0–17.1%), 38–43 correlated with a 5-year survival of 20% (95% CI = 13–27%), 44–47 correlated with a 5-year survival of 48.3% (95% CI = 41.5–55.2%), 48–49 correlated to a 5-year survival of 72.1% (95% CI = 65.6–78.6%), and 50–52 correlated to a 5-year survival of 84.7% (95% CI = 79.6–89.8%). The bootstrap method confirmed the reliability of the score. Prognostic factors significantly associated with survival on both UV and MV analyses were used to construct a valid scoring system that can be used to predict survival of NSCLC patients. Optimally, this score could be used when counseling patients, and designing future trials

  13. High-Temperature Short-Time Pasteurization System for Donor Milk in a Human Milk Bank Setting

    Directory of Open Access Journals (Sweden)

    Diana Escuder-Vieco

    2018-05-01

    Full Text Available Donor milk is the best alternative for the feeding of preterm newborns when mother's own milk is unavailable. For safety reasons, it is usually pasteurized by the Holder method (62.5°C for 30 min. Holder pasteurization results in a microbiological safe product but impairs the activity of many biologically active compounds such as immunoglobulins, enzymes, cytokines, growth factors, hormones or oxidative stress markers. High-temperature short-time (HTST pasteurization has been proposed as an alternative for a better preservation of some of the biological components of human milk although, at present, there is no equipment available to perform this treatment under the current conditions of a human milk bank. In this work, the specific needs of a human milk bank setting were considered to design an HTST equipment for the continuous and adaptable (time-temperature combination processing of donor milk. Microbiological quality, activity of indicator enzymes and indices for thermal damage of milk were evaluated before and after HTST treatment of 14 batches of donor milk using different temperature and time combinations and compared to the results obtained after Holder pasteurization. The HTST system has accurate and simple operation, allows the pasteurization of variable amounts of donor milk and reduces processing time and labor force. HTST processing at 72°C for, at least, 10 s efficiently destroyed all vegetative forms of microorganisms present initially in raw donor milk although sporulated Bacillus sp. survived this treatment. Alkaline phosphatase was completely destroyed after HTST processing at 72 and 75°C, but γ-glutamil transpeptidase showed higher thermoresistance. Furosine concentrations in HTST-treated donor milk were lower than after Holder pasteurization and lactulose content for HTST-treated donor milk was below the detection limit of analytical method (10 mg/L. In conclusion, processing of donor milk at 72°C for at least 10 s in

  14. High-Temperature Short-Time Pasteurization System for Donor Milk in a Human Milk Bank Setting.

    Science.gov (United States)

    Escuder-Vieco, Diana; Espinosa-Martos, Irene; Rodríguez, Juan M; Corzo, Nieves; Montilla, Antonia; Siegfried, Pablo; Pallás-Alonso, Carmen R; Fernández, Leónides

    2018-01-01

    Donor milk is the best alternative for the feeding of preterm newborns when mother's own milk is unavailable. For safety reasons, it is usually pasteurized by the Holder method (62.5°C for 30 min). Holder pasteurization results in a microbiological safe product but impairs the activity of many biologically active compounds such as immunoglobulins, enzymes, cytokines, growth factors, hormones or oxidative stress markers. High-temperature short-time (HTST) pasteurization has been proposed as an alternative for a better preservation of some of the biological components of human milk although, at present, there is no equipment available to perform this treatment under the current conditions of a human milk bank. In this work, the specific needs of a human milk bank setting were considered to design an HTST equipment for the continuous and adaptable (time-temperature combination) processing of donor milk. Microbiological quality, activity of indicator enzymes and indices for thermal damage of milk were evaluated before and after HTST treatment of 14 batches of donor milk using different temperature and time combinations and compared to the results obtained after Holder pasteurization. The HTST system has accurate and simple operation, allows the pasteurization of variable amounts of donor milk and reduces processing time and labor force. HTST processing at 72°C for, at least, 10 s efficiently destroyed all vegetative forms of microorganisms present initially in raw donor milk although sporulated Bacillus sp. survived this treatment. Alkaline phosphatase was completely destroyed after HTST processing at 72 and 75°C, but γ-glutamil transpeptidase showed higher thermoresistance. Furosine concentrations in HTST-treated donor milk were lower than after Holder pasteurization and lactulose content for HTST-treated donor milk was below the detection limit of analytical method (10 mg/L). In conclusion, processing of donor milk at 72°C for at least 10 s in this HTST system

  15. High-Temperature Short-Time Pasteurization System for Donor Milk in a Human Milk Bank Setting

    Science.gov (United States)

    Escuder-Vieco, Diana; Espinosa-Martos, Irene; Rodríguez, Juan M.; Corzo, Nieves; Montilla, Antonia; Siegfried, Pablo; Pallás-Alonso, Carmen R.; Fernández, Leónides

    2018-01-01

    Donor milk is the best alternative for the feeding of preterm newborns when mother's own milk is unavailable. For safety reasons, it is usually pasteurized by the Holder method (62.5°C for 30 min). Holder pasteurization results in a microbiological safe product but impairs the activity of many biologically active compounds such as immunoglobulins, enzymes, cytokines, growth factors, hormones or oxidative stress markers. High-temperature short-time (HTST) pasteurization has been proposed as an alternative for a better preservation of some of the biological components of human milk although, at present, there is no equipment available to perform this treatment under the current conditions of a human milk bank. In this work, the specific needs of a human milk bank setting were considered to design an HTST equipment for the continuous and adaptable (time-temperature combination) processing of donor milk. Microbiological quality, activity of indicator enzymes and indices for thermal damage of milk were evaluated before and after HTST treatment of 14 batches of donor milk using different temperature and time combinations and compared to the results obtained after Holder pasteurization. The HTST system has accurate and simple operation, allows the pasteurization of variable amounts of donor milk and reduces processing time and labor force. HTST processing at 72°C for, at least, 10 s efficiently destroyed all vegetative forms of microorganisms present initially in raw donor milk although sporulated Bacillus sp. survived this treatment. Alkaline phosphatase was completely destroyed after HTST processing at 72 and 75°C, but γ-glutamil transpeptidase showed higher thermoresistance. Furosine concentrations in HTST-treated donor milk were lower than after Holder pasteurization and lactulose content for HTST-treated donor milk was below the detection limit of analytical method (10 mg/L). In conclusion, processing of donor milk at 72°C for at least 10 s in this HTST system

  16. Detection of cytomegalovirus in blood donors by PCR using the digene SHARP signal system assay: effects of sample preparation and detection methodology.

    OpenAIRE

    Krajden, M; Shankaran, P; Bourke, C; Lau, W

    1996-01-01

    Cytomegalovirus (CMV) is an important cause of transfusion-associated morbidity and mortality; however, only 0.4 to 12% of the blood products obtained from seropositive blood donors transmit infection. The effects of three commercially available whole-blood sample preparation kits on the detection of CMV PCR products by a semiquantitative adaptation of the Digene SHARP Signal System Assay (DSSSA) in samples from volunteer blood donors was assessed. Of 101 samples from seropositive blood donor...

  17. Ultrasmall magnetic field-effect and sign reversal in transistors based on donor/acceptor systems

    Directory of Open Access Journals (Sweden)

    Thomas Reichert

    2017-05-01

    Full Text Available We present magnetoresistive organic field-effect transistors featuring ultrasmall magnetic field-effects as well as a sign reversal. The employed material systems are coevaporated thin films with different compositions consisting of the electron donor 2,2',7,7'-tetrakis-(N,N-di-p-methylphenylamino-9,9'-spirobifluorene (Spiro-TTB and the electron acceptor 1,4,5,8,9,12-hexaazatriphenylene hexacarbonitrile (HAT-CN. Intermolecular charge transfer between Spiro-TTB and HAT-CN results in a high intrinsic charge carrier density in the coevaporated films. This enhances the probability of bipolaron formation, which is the process responsible for magnetoresistance effects in our system. Thereby even ultrasmall magnetic fields as low as 0.7 mT can influence the resistance of the charge transport channel. Moreover, the magnetoresistance is drastically influenced by the drain voltage, resulting in a sign reversal. An average B0 value of ≈2.1 mT is obtained for all mixing compositions, indicating that only one specific quasiparticle is responsible for the magnetoresistance effects. All magnetoresistance effects can be thoroughly clarified within the framework of the bipolaron model.

  18. Zonal NePhRO scoring system: a superior renal tumor complexity classification model.

    Science.gov (United States)

    Hakky, Tariq S; Baumgarten, Adam S; Allen, Bryan; Lin, Hui-Yi; Ercole, Cesar E; Sexton, Wade J; Spiess, Philippe E

    2014-02-01

    Since the advent of the first standardized renal tumor complexity system, many subsequent scoring systems have been introduced, many of which are complicated and can make it difficult to accurately measure data end points. In light of these limitations, we introduce the new zonal NePhRO scoring system. The zonal NePhRO score is based on 4 anatomical components that are assigned a score of 1, 2, or 3, and their sum is used to classify renal tumors. The zonal NePhRO scoring system is made up of the (Ne)arness to collecting system, (Ph)ysical location of the tumor in the kidney, (R)adius of the tumor, and (O)rganization of the tumor. In this retrospective study, we evaluated patients exhibiting clinical stage T1a or T1b who underwent open partial nephrectomy performed by 2 genitourinary surgeons. Each renal unit was assigned both a zonal NePhRO score and a RENAL (radius, exophytic/endophytic properties, nearness of tumor to the collecting system or sinus in millimeters, anterior/posterior, location relative to polar lines) score, and a blinded reviewer used the same preoperative imaging study to obtain both scores. Additional data points gathered included age, clamp time, complication rate, urine leak rate, intraoperative blood loss, and pathologic tumor size. One hundred sixty-six patients underwent open partial nephrectomy. There were 37 perioperative complications quantitated using the validated Clavien-Dindo system; their occurrence was predicted by the NePhRO score on both univariate and multivariate analyses (P = .0008). Clinical stage, intraoperative blood loss, and tumor diameter were all correlated with the zonal NePhRO score on univariate analysis only. The zonal NePhRO scoring system is a simpler tool that accurately predicts the surgical complexity of a renal lesion. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Slit Lamp-Based Ocular Scoring Systems in Toxicology and Drug Development: A Literature Survey.

    Science.gov (United States)

    Eaton, Joshua Seth; Miller, Paul E; Bentley, Ellison; Thomasy, Sara M; Murphy, Christopher J

    2017-12-01

    To present a survey of the features of published slit lamp-based scoring systems and their applicability in the context of modern ocular toxicology and drug development. References describing original or modified slit lamp-based scoring systems for human or veterinary clinical patients or in investigative or toxicologic research were collected following a comprehensive literature review using textbooks and online publication searches. Each system's indications and features were compiled to facilitate comparison. Literature review identified 138 original or modified scoring systems. Most (48%) were published for evaluation of the ocular surface, 34% for the general anterior segment, and 18% for the lens. Most systems were described for assessment of human patients (50%) and small albino laboratory species such as rabbits (19%), rats (12%), and mice (8%). Systems described for pigmented laboratory species and for larger species such as dogs, cats, pigs, and nonhuman primates (NHPs) were comparatively underrepresented. No systems described a lens scoring scheme specific to the dog, cat, pig, or NHP. Scoring schemes for aqueous and vitreous cells were infrequently described for laboratory species. Many slit lamp-based scoring systems have been published, but the features of each differ and complicate translation of findings between different species. Use and interpretation of any scoring system in toxicology and drug development must be done with awareness of the limitations of the system being used.

  20. Preoperative selective desensitization of live donor liver transplant recipients considering the degree of T lymphocyte cross-match titer, model for end-stage liver disease score, and graft liver volume.

    Science.gov (United States)

    Hong, Geun; Yi, Nam-Joon; Suh, Suk-won; Yoo, Tae; Kim, Hyeyoung; Park, Min-Su; Choi, YoungRok; Lee, Kyungbun; Lee, Kwang-Woong; Park, Myoung Hee; Suh, Kyung-Suk

    2014-05-01

    Several studies have suggested that a positive lymphocyte cross-matching (XM) is associated with low graft survival rates and a high prevalence of acute rejection after adult living donor liver transplantations (ALDLTs) using a small-for-size graft. However, there is still no consensus on preoperative desensitization. We adopted the desensitization protocol from ABO-incompatible LDLT. We performed desensitization for the selected patients according to the degree of T lymphocyte cross-match titer, model for end-stage liver disease (MELD) score, and graft liver volume. We retrospectively evaluated 230 consecutive ALDLT recipients for 5 yr. Eleven recipients (4.8%) showed a positive XM. Among them, five patients with the high titer (> 1:16) by antihuman globulin-augmented method (T-AHG) and one with a low titer but a high MELD score of 36 were selected for desensitization: rituximab injection and plasmapheresis before the transplantation. There were no major side effects of desensitization. Four of the patients showed successful depletion of the T-AHG titer. There was no mortality and hyperacute rejection in lymphocyte XM-positive patients, showing no significant difference in survival outcome between two groups (P=1.000). In conclusion, this desensitization protocol for the selected recipients considering the degree of T lymphocyte cross-match titer, MELD score, and graft liver volume is feasible and safe.

  1. Comparison of risk scoring systems for patients presenting with upper gastrointestinal bleeding: international multicentre prospective study.

    Science.gov (United States)

    Stanley, Adrian J; Laine, Loren; Dalton, Harry R; Ngu, Jing H; Schultz, Michael; Abazi, Roseta; Zakko, Liam; Thornton, Susan; Wilkinson, Kelly; Khor, Cristopher J L; Murray, Iain A; Laursen, Stig B

    2017-01-04

     To compare the predictive accuracy and clinical utility of five risk scoring systems in the assessment of patients with upper gastrointestinal bleeding.  International multicentre prospective study.  Six large hospitals in Europe, North America, Asia, and Oceania.  3012 consecutive patients presenting over 12 months with upper gastrointestinal bleeding.  Comparison of pre-endoscopy scores (admission Rockall, AIMS65, and Glasgow Blatchford) and post-endoscopy scores (full Rockall and PNED) for their ability to predict predefined clinical endpoints: a composite endpoint (transfusion, endoscopic treatment, interventional radiology, surgery, or 30 day mortality), endoscopic treatment, 30 day mortality, rebleeding, and length of hospital stay. Optimum score thresholds to identify low risk and high risk patients were determined.  The Glasgow Blatchford score was best (area under the receiver operating characteristic curve (AUROC) 0.86) at predicting intervention or death compared with the full Rockall score (0.70), PNED score (0.69), admission Rockall score (0.66, and AIMS65 score (0.68) (all P<0.001). A Glasgow Blatchford score of ≤1 was the optimum threshold to predict survival without intervention (sensitivity 98.6%, specificity 34.6%). The Glasgow Blatchford score was better at predicting endoscopic treatment (AUROC 0.75) than the AIMS65 (0.62) and admission Rockall scores (0.61) (both P<0.001). A Glasgow Blatchford score of ≥7 was the optimum threshold to predict endoscopic treatment (sensitivity 80%, specificity 57%). The PNED (AUROC 0.77) and AIMS65 scores (0.77) were best at predicting mortality, with both superior to admission Rockall score (0.72) and Glasgow Blatchford score (0.64; P<0.001). Score thresholds of ≥4 for PNED, ≥2 for AIMS65, ≥4 for admission Rockall, and ≥5 for full Rockall were optimal at predicting death, with sensitivities of 65.8-78.6% and specificities of 65.0-65.3%. No score was helpful at predicting rebleeding or length

  2. Anatomic variations in vascular and collecting systems of kidneys from deceased donors.

    Science.gov (United States)

    Costa, H C; Moreira, R J; Fukunaga, P; Fernandes, R C; Boni, R C; Matos, A C

    2011-01-01

    Nephroureterectomy for transplantation has increased owing to the greater number of deceased donors. Anatomic variations may complicate the procedure or, if unrecognized, compromise the viability of kidneys for transplantation. We reviewed 254 surgical descriptions of nephroureterectomy specimens from January 2008 to December 2009. All organs collected according by standard techniques were evaluated for age, cause of death, renal function, frequency of injury during the procedure, as well as variations in the vascular and collecting systems. The mean donor age was 42 years (range, 2-74). The mean serum creatinine was 1.2 mg/dL (range, 1.0-7.0). The causes of death were cerebrovascular cause (stroke; n = 130), traumatic brain injury (n = 81) or other cause (n = 43). Among the anatomic variations: 8.6% (n = 22) were right arterial anatomical variations: 19 cases with 2 arteries and 3 cases with 3 arteries. In 25 cases (9.8%) the identified variation was the left artery: 2 arteries (n = 23), 3 arteries (n = 1) and 4 arteries (n = 1). We observed 9.8% on right side and 1.5% on left side venous anatomic variations, including 24 cases with 2 veins on the right side and 4 cases with 2 veins on the left side. Three cases of a retroaortic left renal vein and 1 case of a retro necklace vein (anterior and posterior to the aorta). Two cases of ureteral duplication were noted on the left and 1 on the right kidney. There were 3 horseshoe and 1 pelvic kidney. In 7.5% of cases, an injury to the graft included ureteral (n = 3), arterial (n = 10), or venous (n = 6). The most common anatomic variation was arterial (17.8%). Duplication of the renal vein was more frequent on the right. The high incidences of anatomic variations require more attention in the dissection of the renal hilum to avoid an injury that may compromise the graft. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Role of RENAL nephrometry scoring system in planning surgical intervention in patients with localized renal mas

    OpenAIRE

    Mohamed Samir Shaaban; Tamer Mohammed Abou Youssif; Ahmed Mostafa; Hossam Eldin Hegazy; Mohammed Adel Atta

    2015-01-01

    Purpose: The study was designed to validate the value of preoperative planning using RENAL nephrometry scoring system in patients having organ confined renal tumors and undergoing surgical intervention and to assess its correlation with the surgical technique. Patient and methods: Forty patients with organ-confined renal masses underwent RENAL nephrometry scoring which was correlated with the surgical technique either radical or nephron-sparing surgery. Result: RENAL nephrometry scoring...

  4. Should We Formulate an Incentivized Model Facilitating Kidney Donation from Living Donors? A Focus on Turkey's Current System.

    Science.gov (United States)

    Avci, Ercan

    2018-04-23

    Kidney transplantation is a lifesaving medical treatment. However, very high demand for kidneys with low kidney donation causes a black market that exploits patients' desperation and donors' vulnerability. The current kidney donation programs fail to produce promising results to avoid illegal and unethical kidney trafficking and commercialism. Even though the primary goal of kidney donation is to increase the number of deceased organ donations, in some countries, like Turkey, due to religious or cultural concerns, it is impossible to supply adequate deceased kidney donations. In this view, the aim of this paper is to examine kidney trafficking in the scope of Turkey's current organ donation system and propose a new model, named the Incentivized Kidney Donation Model (IKDM), to increase kidney donation from living donors. The model encompasses the following benefits offered to kidney donors; lifetime health insurance, exemptions from copayments/contribution shares, priority when receiving an organ, priority when finding a job, income tax exemptions for salaried employees, and free or discounted public utilities. This normative model has the potential to promote donors' altruistic acts as well as the solidarity and loyalty among members of a society without violating ethical values and internationally accepted principles. © 2018 John Wiley & Sons Ltd.

  5. Applicability and prognostic value of histologic scoring systems in primary sclerosing cholangitis

    NARCIS (Netherlands)

    de Vries, Elisabeth M. G.; Verheij, Joanne; Hubscher, Stefan G.; Leeflang, Mariska M. G.; Boonstra, Kirsten; Beuers, Ulrich; Ponsioen, Cyriel Y.

    2015-01-01

    Primary sclerosing cholangitis (PSC) is a chronic cholestatic liver disease. At present, there is no appropriate histologic scoring system available for PSC, evaluating both degree of necroinflammatory activity (grade) and fibrosis (stage). The aim of this study was to assess if three scoring

  6. Implementing paediatric early warning scores systems in the Netherlands: future implications.

    NARCIS (Netherlands)

    Groot, J.F. de; Damen, N.; Loos, E. de; Steeg, L. van de; Rosias, P.; Bruijn, M.; Goorhuis, J.; Wagner, C.

    2018-01-01

    Background: Paediatric Early Warning Scores (PEWS) are increasingly being used for early identification and management of clinical deterioration in paediatric patients. A PEWS system includes scores, cut-off points and appropriate early intervention. In 2011, The Dutch Ministry of Health advised

  7. External validation of a clinical scoring system for the risk of gestational diabetes mellitus

    NARCIS (Netherlands)

    van Leeuwen, M.; Opmeer, B. C.; Zweers, E. J. K.; van Ballegooie, E.; ter Brugge, H. G.; de Valk, H. W.; Visser, G. H. A.; Mol, B. W. J.

    Aim: A prediction rule for gestational diabetes mellitus (GDM) could be helpful in early detection and increased efficiency of screening. A prediction rule by means of a clinical scoring system is available, but has never been validated externally. The aim of this study was to validate the scoring

  8. Simplified Therapeutic Intervention Scoring System : The TISS-28 items - Results from a multicenter study

    NARCIS (Netherlands)

    Miranda, DR; deRijk, A; Schaufeli, W

    Objectives: To validate a simplified version of the Therapeutic Intervention Scoring System, the TISS-28, and to determine the association of TISS-28 with the time spent on scored and nonscored nursing activities. Design: Prospective, multicenter study. Setting: Twenty-two adult medical, surgical,

  9. A dysmorphology score system for assessing embryo abnormalities in rat whole embryo culture.

    Science.gov (United States)

    Zhang, Cindy X; Danberry, Tracy; Jacobs, Mary Ann; Augustine-Rauch, Karen

    2010-12-01

    The rodent whole embryo culture (WEC) system is a well-established model for characterizing developmental toxicity of test compounds and conducting mechanistic studies. Laboratories have taken various approaches in describing type and severity of developmental findings of organogenesis-stage rodent embryos, but the Brown and Fabro morphological score system is commonly used as a quantitative approach. The associated score criteria is based upon developmental stage and growth parameters, where a series of embryonic structures are assessed and assigned respective scores relative to their gestational stage, with a Total Morphological Score (TMS) assigned to the embryo. This score system is beneficial because it assesses a series of stage-specific anatomical landmarks, facilitating harmonized evaluation across laboratories. Although the TMS provides a quantitative approach to assess growth and determine developmental delay, it is limited to its ability to identify and/or delineate subtle or structure-specific abnormalities. Because of this, the TMS may not be sufficiently sensitive for identifying compounds that induce structure or organ-selective effects. This study describes a distinct morphological score system called the "Dysmorphology Score System (DMS system)" that has been developed for assessing gestation day 11 (approximately 20-26 somite stage) rat embryos using numerical scores to differentiate normal from abnormal morphology and define the respective severity of dysmorphology of specific embryonic structures and organ systems. This method can also be used in scoring mouse embryos of the equivalent developmental stage. The DMS system enhances capabilities to rank-order compounds based upon teratogenic potency, conduct structure- relationships of chemicals, and develop statistical prediction models to support abbreviated developmental toxicity screens. © 2010 Wiley-Liss, Inc.

  10. Organic donor-acceptor thin film systems. Towards optimized growth conditions

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Kerstin Andrea

    2009-06-30

    In this work the preparation of organic donor-acceptor thin films was studied. A chamber for organic molecular beam deposition was designed and integrated into an existing deposition system for metallic thin films. Furthermore, the deposition system was extended by a load-lock with integrated bake-out function, a chamber for the deposition of metallic contacts via stencil mask technique and a sputtering chamber. For the sublimation of the organic compounds several effusion cells were designed. The evaporation characteristic and the temperature profile within the cells was studied. Additionally, a simulation program was developed, which calculates the evaporation characteristics of different cell types. The following processes were integrated: evaporation of particles, migration on the cell walls and collisions in the gas phase. It is also possible to consider a temperature gradient within the cell. All processes can be studied separately and their relative strength can be varied. To verify the simulation results several evaporation experiments with different cell types were employed. The thickness profile of the prepared thin films was measured position-dependently. The results are in good agreement with the simulation. Furthermore, the simulation program was extended to the field of electron beam induced deposition (EBID). The second part of this work deals with the preparation and characterization of organic thin films. The focus hereby lies on the charge transfer salt (BEDT-TTF)(TCNQ), which has three known structure variants. Thin films were prepared by different methods of co-evaporation and were studied with optical microscopy, X-ray diffraction and energy dispersive X-ray spectroscopy (EDX).The formation of the monoclinic phase of (BEDT-TTF)(TCNQ) could be shown. As a last part tunnel structures were prepared as first thin film devices and measured in a He{sub 4} cryostat. (orig.)

  11. A novel scoring system for predicting adherent placenta in women with placenta previa.

    Science.gov (United States)

    Tanimura, Kenji; Morizane, Mayumi; Deguchi, Masashi; Ebina, Yasuhiko; Tanaka, Utaru; Ueno, Yoshiko; Kitajima, Kazuhiro; Maeda, Tetsuo; Sugimura, Kazuro; Yamada, Hideto

    2018-04-01

    Placenta previa (PP) is one of the most significant risk factors for adherent placenta (AP). The aim of this study was to evaluate the diagnostic efficacy of a novel scoring system for predicting AP in pregnant women with PP. This prospective cohort study enrolled 175 women with PP. The placenta previa with adherent placenta score (PPAP score) is composed of 2 categories: (1) past history of cesarean section (CS), surgical abortion, and/or uterine surgery; and (2) ultrasonography and magnetic resonance imaging findings. Each category is graded as 0, 1, 2, or 4 points, yielding a total score between 0 and 24. When women with PP had PPAP score ≥8, they were considered to be at a high risk for AP and received placement of preoperative internal iliac artery occlusion balloon catheters. If they were found to have AP during CS, they underwent hysterectomy or placenta removal using advanced bipolar with balloon catheter occlusion. The predictive accuracy of PPAP score was evaluated. In total, 23 of the 175 women with PP were diagnosed as having AP, histopathologically or clinically. Twenty-one of 24 women with PPAP score ≥8 had AP, whereas two of 151 women with PPAP score PPAP scoring system may be useful for predicting AP in women with PP. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. A comprehensive scoring system in correlation with perioperative airway management for neonatal Pierre Robin Sequence.

    Directory of Open Access Journals (Sweden)

    Ning Yin

    Full Text Available To evaluate a comprehensive scoring system which combines clinical manifestations of Pierre Robin Sequence (PRS including severity of breathing difficulties, body weight and preoperative Cormack-Lehane grade, for its correlation with perioperative PRS airway management decision.Forty PRS children were retrospectively recruited after surgery. Specialists examined all subjects and scored for clinical manifestations (1´ - 4´, weight gain (1´- 4´, dyspnea scores (1´- 4´, and Cormack-Lehane grade (1´- 4´. The correlation of the integrated scores and the necessity of endotracheal intubation or laryngeal mask application were analyzed. In addition, the score correlation with postoperative dyspnea and/or low pulse oxygen saturation (SPO2 levels after extubation was determined.In our study every individual patient had a score from 0´ to 16´, while the higher in the numbers represented higher risk of breathing difficulty. All patients with comprehensive scores 13 points required a laryngeal mask assisted airway management and were considered to have difficult airways. Dyspnea after extubation and postoperative low SPO2 occurred among patients who scored over 10 points.In PRS patients, preoperative weight gaining status and severity of dyspnea in combination with Cormack-Lehane classification provide a scoring system that could help to optimize airway management decisions such as endotracheal intubation or laryngeal mask airway placement and has the potential to predict postoperative dyspnea or low SPO2 levels.

  13. Therapeutic intervention scoring system-28 (TISS-28: diretrizes para aplicação Therapeutic intervention scoring system-28 (tiss-28: directrices para su aplicación Therapeutic intervention scoring system-28 (tiss-28: directions for application

    Directory of Open Access Journals (Sweden)

    Katia Grillo Padilha

    2005-06-01

    Full Text Available O Therapeutic Intervention Scoring System-28 (TISS-28 é um instrumento que permite dimensionar carga de trabalho de enfermagem em Unidade de Terapia Intensiva e estimar gravidade da doença. Apresenta-se nesta publicação as definições operacionais para sua aplicação, proposta por um grupo de especialistas na área, com vistas a uniformizar o significado de cada um dos itens e evitar vieses de interpretação.El Therapeutic Intervention Scoring System-28 (TISS-28 es un instrumento que permite dimensionar carga de trabajo de enfermería en una Unidad de Terapia Intensiva y estimar la gravedad de la enfermedad. Se presenta en esta publicación las definiciones operacionales para su aplicación, propuesta por un grupo de especialistas en el área, con vistas a uniformizar el significado de cada uno de los items y evitar sesgos de interpretación.Therapeutic Intervention Scoring System-28 (TISS-28 is a tool that enables the measurement of the nursing work load in Intensive Care Units and the estimate of how grave the disease is. In this study are presented the operational definitions for its application, proposed by a group of specialists in the area, with the aim of rendering uniform the meaning of each of the items and preventing interpretation biases.

  14. Dr. Liver: A preoperative planning system of liver graft volumetry for living donor liver transplantation.

    Science.gov (United States)

    Yang, Xiaopeng; Yang, Jae Do; Yu, Hee Chul; Choi, Younggeun; Yang, Kwangho; Lee, Tae Beom; Hwang, Hong Pil; Ahn, Sungwoo; You, Heecheon

    2018-05-01

    Manual tracing of the right and left liver lobes from computed tomography (CT) images for graft volumetry in preoperative surgery planning of living donor liver transplantation (LDLT) is common at most medical centers. This study aims to develop an automatic system with advanced image processing algorithms and user-friendly interfaces for liver graft volumetry and evaluate its accuracy and efficiency in comparison with a manual tracing method. The proposed system provides a sequential procedure consisting of (1) liver segmentation, (2) blood vessel segmentation, and (3) virtual liver resection for liver graft volumetry. Automatic segmentation algorithms using histogram analysis, hybrid level-set methods, and a customized region growing method were developed. User-friendly interfaces such as sequential and hierarchical user menus, context-sensitive on-screen hotkey menus, and real-time sound and visual feedback were implemented. Blood vessels were excluded from the liver for accurate liver graft volumetry. A large sphere-based interactive method was developed for dividing the liver into left and right lobes with a customized cutting plane. The proposed system was evaluated using 50 CT datasets in terms of graft weight estimation accuracy and task completion time through comparison to the manual tracing method. The accuracy of liver graft weight estimation was assessed by absolute difference (AD) and percentage of AD (%AD) between preoperatively estimated graft weight and intraoperatively measured graft weight. Intra- and inter-observer agreements of liver graft weight estimation were assessed by intraclass correlation coefficients (ICCs) using ten cases randomly selected. The proposed system showed significantly higher accuracy and efficiency in liver graft weight estimation (AD = 21.0 ± 18.4 g; %AD = 3.1% ± 2.8%; percentage of %AD > 10% = none; task completion time = 7.3 ± 1.4 min) than the manual tracing method (AD = 70

  15. Evaluating observer agreement of scoring systems for foot integrity and footrot lesions in sheep

    Directory of Open Access Journals (Sweden)

    Foddai Alessandro

    2012-05-01

    be used when developing a scoring system to improve reliability.

  16. A new prognostic scoring system for perforation peritonitis secondary to duodenal ulcers

    International Nuclear Information System (INIS)

    Nomani, A.Z.; Qureshi, M.S.

    2014-01-01

    Objective: To identify prognostic factors for perforated duodenal ulcers and to devise and assess a new scoring system. Methods: The observational prospective study was conducted at the Mayo Hospital, Lahore in two phases: from March 2010 to September 2011; and from October 2011 to July 2012. It included patients with duodenal ulcer perforation who were observed for identifying factors predicting 30-day prognosis. Each of the predictive factor was given a score based on its severity to devise a new scoring system. Chi-square was used for univariate analysis. Multivariate analysis was done using forward stepwise regression. Accuracy of the new scoring system was calculated using receiver operating curve analysis and its validity was evaluated in the second phase of the study. Results: Predictors of poor prognosis included multiple gut perforations, size of largest perforation >0.5cm, amount of peritoneal fluid >1000ml, simple closure, development of complications, post-operative systemic septicaemia and winter/autumn season of presentation. Overall 30-day mortality rate was 32.3% (n=32) and morbidity rate was 21.2% (n=21). The mean score was higher in the ones with poor prognosis (p=0.001). Similarly, the mean score was greater in those with grave prognosis (p=0.001). The scoring system had an overall sensitivity of 85.12% and specificity of 80.67% and was favourably comparable to other scoring systems. Conclusion: The new scoring system is a useful tool in predicting 30-day prognosis for perforated duodenal ulcers in acid peptic disease. (author)

  17. Assessment of Mycoplasma hyopneumoniae-induced Pneumonia using Different Lung Lesion Scoring Systems: a Comparative Review.

    Science.gov (United States)

    Garcia-Morante, B; Segalés, J; Fraile, L; Pérez de Rozas, A; Maiti, H; Coll, T; Sibila, M

    2016-01-01

    Mycoplasma hyopneumoniae is the primary aetiological agent of swine enzootic pneumonia (EP) and one of the major contributors to the porcine respiratory disease complex (PRDC). Gross lung lesions in pigs affected by EP consist of cranioventral pulmonary consolidation (CVPC), usually distributed bilaterally in the apical, intermediate, accessory and cranial parts of the diaphragmatic lobes. Several lung scoring methods are currently in place for the evaluation of CVPC. The aims of this study were (1) to review the lung lesion scoring systems used to assess pneumonia associated with M. hyopneumoniae infection, and (2) to evaluate eight of these scoring systems by applying them to the lungs of 76 pigs with experimentally-induced M. hyopneumoniae pneumonia. A significant correlation between all lung lesion scoring systems was observed and the coefficients of determination in a regression analysis were very high between each pair-wise comparison, except for a unique scoring system based on image analysis. A formula of equivalence between lung scoring methods was developed in order to compare the results obtained with these methods. The present review provides a basis for comparison (even retrospectively) of lesions evaluated using different lung scoring systems. Copyright © 2015. Published by Elsevier Ltd.

  18. Commercial Building Energy Asset Score System: Program Overview and Technical Protocol (Version 1.0)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Na; Gorrissen, Willy J.

    2013-01-11

    The U.S. Department of Energy (DOE) is developing a national voluntary energy asset score system that includes an energy asset score tool to help building owners evaluate their buildings with respect to the score system. The goal of the energy asset score system is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system will allow building owners and managers to compare their building infrastructure against peers and track building upgrade progress over time. The system can also help other building stakeholders (e.g., building operators, tenants, financiers, and appraisers) understand the relative efficiency of different buildings in a way that is independent from their operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset score tool. This report also describes alternative methods that were considered prior to developing the current approach. Finally, this report describes a few features of the program where alternative approaches are still under evaluation.

  19. Developing a cumulative anatomic scoring system for military perineal and pelvic blast injuries.

    Science.gov (United States)

    Mossadegh, Somayyeh; Midwinter, M; Parker, P

    2013-03-01

    Improvised explosive device (IED) yields in Afghanistan have increased resulting in more proximal injuries. The injury severity score (ISS) is an anatomic aggregate score of the three most severely injured anatomical areas but does not accurately predict severity in IED related pelvi-perineal trauma patients. A scoring system based on abbreviated injury score (AIS) was developed to reflect the severity of these injuries in order to better understand risk factors, develop a tool for future audit and improve performance. Using standard AIS descriptors, injury scales were constructed for the pelvis (1, minor to 6, maximal). The perineum was divided into anterior and posterior zones as relevant to injury patterns and blast direction with each soft tissue structure being allocated a score from its own severity scale. A cumulative score, from 1 to 36 for soft tissue, or a maximum of 42 if a pelvic fracture was involved, was created for all structures injured in the anterior and posterior zones. Using this new scoring system, 77% of patients survived with a pelvi-perineal trauma score (PPTS) below 5. There was a significant increase in mortality, number of pelvic fractures and amputations with increase in score when comparing the first group (score 1-5) to the second group (score 6-10). For scores between 6 and 16 survival was 42% and 22% for scores between 17 and 21. In our cohort of 62 survivors, 1 patient with an IED related pelvi-perineal injury had a 'theoretically un-survivable' maximal ISS of 75 and survived, whereas there were no survivors with a PPTS greater than 22 but this group had no-one with an ISS of 75 suggesting ISS is not an accurate reflection of the true severity of pelvi-perineal blast injury. This scoring system is the initial part of a more complex logistic regression model that will contribute towards a unique trauma scoring system to aid surgical teams in predicting fluid requirements and operative timelines. In austere environments, it may also

  20. Evaluation of histological scoring systems for tissue-engineered, repaired and osteoarthritic cartilage

    NARCIS (Netherlands)

    Rutgers, M.; van Pelt, M.J.; Dhert, W.J.A.; Creemers, L.B.; Saris, D.B.F.

    2010-01-01

    Osteoarthritis and Cartilage Volume 18, Issue 1, January 2010, Pages 12-23 -------------------------------------------------------------------------------- Review Evaluation of histological scoring systems for tissue-engineered, repaired and osteoarthritic cartilage M. Rutgers†, M.J.P. van Pelt†,

  1. Usefulness of a clinical scoring system to anticipate difficulty of Norplant removal.

    Science.gov (United States)

    Blumenthal, P D; Remsburg, R E; Glew, G; McGrath, J A; Gaffikin, L

    1995-12-01

    Removal of contraceptive implants (e.g. Norplant) is an issue affecting its worldwide acceptability. Reports of difficult, painful removals have resulted in lawsuits and reduced demand. To improve quality of care, we developed a scoring system to anticipate difficult removals. We report on the usefulness of such a system and present client perspectives about the removal experience. A 9-point scoring system based on the visibility, arrangement, and position (VAP) of Norplant capsules was used to assess the anticipated difficulty of removal in 53 consecutive patients. The VAP score was then correlated with removal time and related parameters. Mean removal time was 14.74 min (range 4.75-47). In 20% of patients, the VAP score indicated a potentially difficult removal and the VAP score correlated significantly with removal time (r = 0.3, p = 0.05). Patients expected removal to be moderately difficult (mean visual analog score 4.7 out of a possible 10), but after removal they rated the actual removal experience as relatively easy (mean score 2.6/10). Before the removal, only 48% of patients said they would recommend Norplant to a friend but after removal, 70% said they would do so. A scoring system such as the VAP score can help identify potentially difficult removals so that an experienced remover can be present at the time of removal or an appropriate referral made. However, the VAP score cannot predict variables such as the density of the subcutaneous fibrous tissue "envelope". Although patient anxiety concerning removal may be high, the presence of a competent remover and an easy removal experience reduces this anxiety and encourages patients to be more positive about this method. The value of having properly trained, competent personnel available to perform removals cannot be over-emphasized.

  2. Experimental and computed dipole moments in donor-bridge-acceptor systems with p-phenylene and p-carboranediyl bridges

    Czech Academy of Sciences Publication Activity Database

    Drož, L.; Fox, M. A.; Hnyk, Drahomír; Low, P.J.; MacBride, J.A.H.; Všetečka, V.

    2009-01-01

    Roč. 74, č. 1 (2009), s. 131-146 ISSN 0010-0765 R&D Projects: GA MŠk LC523 Grant - others:EPSRC(GB) GR/S80943/01 Institutional research plan: CEZ:AV0Z40320502 Keywords : donor-bridge-acceptor systems * p-carboranylenes * dipole moments Subject RIV: CA - Inorganic Chemistry Impact factor: 0.856, year: 2009

  3. A Posterior Circulation Ischemia Risk Score System to Assist the Diagnosis of Dizziness.

    Science.gov (United States)

    Chen, Ru; Su, Rui; Deng, Mingzhu; Liu, Jia; Hu, Qing; Song, Zhi

    2018-02-01

    We aimed to establish a risk score system without radio-image examination, which could help clinicians to differentiate patients with vertigo and posterior circulation ischemia (PCI) rapidly from the other dizzy patients. We analyzed 304 patients with vertigo (50% PCI). The attributes with more significant contributions were selected as the risk factors for the PCI risk score system, and every one of them was assigned a value according to their respective odds ratio values. We also compared the respective receiver operating characteristic curves of the 3 diagnostic methods (PCI score system, ABCD 2 , and Essen score systems) to evaluate their prediction effectiveness. Nine risk factors were ultimately selected for PCI score system, including high blood pressure (1'), diabetes mellitus (1'), ischemic stroke (1'), rotating and rocking (-1'), difficulty in speech (5'), tinnitus (-5'), limb and sensory deficit (5'), gait ataxia (1'), and limb ataxia (5'). According to their respective PCI risk scores, the patients were divided into 3 subgroups: low risk (≤0', risk 95.0%). When 0' was selected as a cutoff point for differentiating the patients with PCI from patients without PCI, the sensitivity was 94.1%, with a specificity of 41.4%. The areas under the receiver operator curve value of PCI score system was .82 (P = .000), much higher than the areas under the receiver operator curve value of ABCD 2 (.69, P = .000) and that of the Essen system (.67, P = .000) CONCLUSION: The PCI score system could help clinicians to differentiate patients with vertigo and PCI rapidly from the other dizzy patients. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  4. The development of a preliminary ultrasonographic scoring system for features of hand osteoarthritis.

    LENUS (Irish Health Repository)

    Keen, H I

    2008-05-01

    Painful osteoarthritis (OA) of the hand is common and a validated ultrasound (US) scoring system would be valuable for epidemiological and therapeutic outcome studies. US is increasingly used to assess peripheral joints, though most of the US focus in rheumatic diseases has been on rheumatoid arthritis. We aimed to develop a preliminary US hand OA scoring system, initially focusing on relevant pathological features with potentially high reliability.

  5. Validation of the prognostic value of histologic scoring systems in primary sclerosing cholangitis

    DEFF Research Database (Denmark)

    de Vries, Elisabeth M G; de Krijger, Manon; Färkkilä, Martti

    2017-01-01

    across a multicenter PSC cohort. Liver biopsies from PSC patients were collected from seven European institutions. Histologic scoring was performed using the Nakanuma, Ishak, and Ludwig scoring systems. Biopsies were independently scored by six liver pathologists for interobserver agreement.......19-5.80] for endpoint 2 and HR, 2.06 [95% CI, 1.09-3.89] for endpoint 3). Only the Nakanuma staging system was independently associated with endpoint 1: HR, 2.14 (95% CI, 1.22-3.77). Interobserver agreement was moderate for Nakanuma stage (κ = 0.56) and substantial for Nakanuma component fibrosis (κ = 0.67), Ishak...

  6. Validation of the computed assessment of cleansing score with the Mirocam® system

    Directory of Open Access Journals (Sweden)

    Ana Ponte

    Full Text Available Background and aims: A computed assessment of cleansing (CAC score was developed to objectively evaluate small-bowel cleansing in the PillCam capsule endoscopy (CE system and to overcome the subjectivity and complexity of previous scoring systems. Our study aimed to adapt the CAC score to the Mirocam® system, evaluate its reliability with the Mirocam® CE system and compare it with three validated subjective grading scales. Patients and methods: Thirty CE were prospectively and independently reviewed by two authors who classified the degree of small-bowel cleanliness according to a quantitative index, a qualitative evaluation and an overall adequacy assessment. The authors were blinded for the CAC score of each CE, which was calculated as ([mean intensity of the red channel]/[mean intensity of the green channel] - 1 x 10. The mean intensities of the red and green channels of the small-bowel segment of the "Map View" bar in the Miroview Client® were determined using the histogram option of two photo-editing software. Results: There was a strong agreement between both CE readers for each of the three subjective scales used. The reproducibility of the CAC score was excellent and identical results were obtained with the two photo-editing software. Regarding the comparison between the CAC score and the subjective scales, there was a moderate-to-good agreement with the quantitative index, qualitative evaluation and overall adequacy assessment. Conclusions: CAC score represents an objective and feasible score in the assessment of small-bowel cleansing in the Mirocam® CE system, and could be used per se or as part of a more comprehensive score.

  7. A comparative study on assessment procedures and metric properties of two scoring systems of the Coma Recovery Scale-Revised items: standard and modified scores.

    Science.gov (United States)

    Sattin, Davide; Lovaglio, Piergiorgio; Brenna, Greta; Covelli, Venusia; Rossi Sebastiano, Davide; Duran, Dunja; Minati, Ludovico; Giovannetti, Ambra Mara; Rosazza, Cristina; Bersano, Anna; Nigri, Anna; Ferraro, Stefania; Leonardi, Matilde

    2017-09-01

    The study compared the metric characteristics (discriminant capacity and factorial structure) of two different methods for scoring the items of the Coma Recovery Scale-Revised and it analysed scale scores collected using the standard assessment procedure and a new proposed method. Cross sectional design/methodological study. Inpatient, neurological unit. A total of 153 patients with disorders of consciousness were consecutively enrolled between 2011 and 2013. All patients were assessed with the Coma Recovery Scale-Revised using standard (rater 1) and inverted (rater 2) procedures. Coma Recovery Scale-Revised score, number of cognitive and reflex behaviours and diagnosis. Regarding patient assessment, rater 1 using standard and rater 2 using inverted procedures obtained the same best scores for each subscale of the Coma Recovery Scale-Revised for all patients, so no clinical (and statistical) difference was found between the two procedures. In 11 patients (7.7%), rater 2 noted that some Coma Recovery Scale-Revised codified behavioural responses were not found during assessment, although higher response categories were present. A total of 51 (36%) patients presented the same Coma Recovery Scale-Revised scores of 7 or 8 using a standard score, whereas no overlap was found using the modified score. Unidimensionality was confirmed for both score systems. The Coma Recovery Scale Modified Score showed a higher discriminant capacity than the standard score and a monofactorial structure was also supported. The inverted assessment procedure could be a useful evaluation method for the assessment of patients with disorder of consciousness diagnosis.

  8. Electron Transfer in Donor-Bridge-Acceptor Systems and Derived Materials

    NARCIS (Netherlands)

    Oosterbaan, W.D.

    2002-01-01

    Some aspects of photoinduced electron transfer (ET) in (electron donor)-bridge-(electron acceptor) compounds (D-B-A) and derived materials are investigated. Aim I is to determine how and to which extent non-conjugated double bonds in an otherwise saturated hydrocarbon bridge affect the rate of

  9. Nano-scale control of energy transfer in the system 'donor-acceptor'

    International Nuclear Information System (INIS)

    Malyukin, Yu.V.; Yefimova, S.L.; Lebedenko, A.N.; Sorokin, A.V.; Borovoy, I.A.

    2005-01-01

    Fluorescence resonance energy transfer (FRET) in a cascade scheme between three amphiphilic dyes 3,3'-dioctadecyloxacarbocyanine perchlorate (DiOC 18 (3), donor), 1,1'-dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate (DiIC 18 (3), acceptor/donor) and 1,1'-dioctadecyl-3,3,3',3'-tetramethylindodicarbocyanine perchlorate (DiIC 18 (5), acceptor) has been investigated at low dye concentration (10 -5 mol/l) in water-micellar solutions due to a forced assembling of dyes in nanoscale volume. The experimental data have revealed that sodium dodecyl sulfate (SDS) micelles solubilize dye molecules such that their hydrophilic heads are in contact with water, while hydrophobic tails are embedded into the hydrocarbon core of the micelle. FRET efficiency has been found to depend on the concentration of dyes in micelles and the most effective when each SDS micelle contains 1 donor (DiOC 18 (3)), 2 acceptor/donor (DiIC 18 (3)) and 4 acceptor (DiIC 18 (5)) molecules

  10. The Use of the OMERACT Ultrasound Tenosynovitis Scoring System in Multicenter Clinical Trials.

    Science.gov (United States)

    Ammitzbøll-Danielsen, Mads; Østergaard, Mikkel; Naredo, Esperanza; Iagnocco, Annamaria; Möller, Ingrid; D'Agostino, Maria-Antonietta; Gandjbakhch, Frédérique; Terslev, Lene

    2018-02-01

    To test the sensitivity to change of the Outcome Measures in Rheumatology Clinical Trials (OMERACT) ultrasound (US) scoring system for tenosynovitis when applied in a multicenter design. RA patients with US-verified tenosynovitis were recruited when scheduled for treatment intensification. Tenosynovitis was assessed at baseline, and 3 and 6 months followup, using the semiquantitative OMERACT scoring system. Expressed in median (25th; 75th percentiles), the overall greyscale and Doppler score decreased significantly from baseline at 4 (2; 7) and 3 (2; 6), to 6 months at 2 (0; 3) and 0 (0; 1, p The OMERACT US scoring system for tenosynovitis showed high responsiveness, supporting its use for diagnosing and monitoring tenosynovitis in multicenter trials.

  11. Towards Establishing a Standardized Magnetic Resonance Imaging Scoring System for Temporomandibular Joints in Juvenile Idiopathic Arthritis

    DEFF Research Database (Denmark)

    Tolend, Mirkamal A; Twilt, Marinka; Cron, Randy Q

    2017-01-01

    OBJECTIVES: The temporomandibular joints (TMJs) are frequently affected in children with juvenile idiopathic arthritis (JIA). Early detection is challenging, as major variation is present in scoring TMJ pathology on Magnetic Resonance Imaging (MRI). Consensus-driven development and validation...... of a MRI scoring system for TMJs has important clinical utility in timely improvement of diagnosis, and serving as an outcome measure. We report on a multi-institutional collaboration towards developing a TMJ MRI scoring system for JIA. METHODS: Seven readers independently assessed MRI scans from 21...... preferable for assessing minor joint changes over time. Eight items were considered sufficiently reliable and/or important for integration into the consensus scoring system: bone marrow edema and enhancement (avICC=0.57-0.61; %SDD=±45-63% prior to re-defining), condylar flattening (0.95-0.96; ±23...

  12. MRI system scoring for differentiation of malignant versus benign stricture of the common bile duct

    Directory of Open Access Journals (Sweden)

    Savastano S

    2016-11-01

    Full Text Available The purpose of this study was to evaluate the ability of magnetic resonance imaging (MRI to differentiate between malignant and benign strictures of the common bile duct by using a scoring system. MRI scans of 34 patients with indeterminate biliary stricture on prior imaging were reviewed; non-enhanced MRI, magnetic resonance cholangiopancreatography (MRCP, diffusion weighted imaging, and contrast-enhanced MRIs were considered for analysis. Ten radiologic findings were significant for malignancy: luminal irregularity, post-contrast conspicuity, high signal intensity on diffusion weighted MRI, luminal stenosis asymmetry, T2-weighted MRI signal intensity, indistinct outer border, abrupt stenosis, bile duct dilatation ≥ 12.5 mm, stenosis length ≥ 10.5 mm, and wall thickness ≥ 4.5 mm. Since none of these findings was pathognomonic for malignancy, a simple system scoring based on statistically significant findings was developed, where each of the above findings counts for one point. A score of 6 or higher was found only in patients with a malignant stricture of the common bile duct; 70% of patients with a benign stenosis had a score of 1, or 2, and all patients with benign lesions had scores of less than 5. This MRI scoring system can assist in the differential diagnosis of common bile duct stricture with high accuracy; to be widely applicable, the MRI score needs to be validated in a prospective patient population.

  13. [Different scoring systems to evaluate the prognosis of Fournier's gangrene: A comparative study].

    Science.gov (United States)

    Zhu, Xiao-dong; Ding, Fei; Wang, Guo-dong; Shao, Qiang

    2015-08-01

    To sum up the experience in diagnosis and treatment of Fournier's gangrene and find an optimal evaluation tool for its prognosis by comparing currently used prognostic scoring systems. We retrospectively analyzed 16 cases of Fournier's gangrene diagnosed and surgically treated in our hospital between 2004 and 2012. Using Fournier's Gangrene Severity Index (FGSI), Uludag Fournier's Gangrene Severity Index (UFGSI), Age-Adjusted Charlson Comorbidity Index (ACCI), and Surgical Apgar Score (sAPGAR) , we obtained the prognostic scores of the patients and made comparisons among different scoring systems. FGSI, UFGSI, ACCI, and sAPGAR were all clinically used scoring systems. Statistically significant differences were found in the scores of ACCI and UFGSI but not in those of FGSI and sAPGAR between the death and survival groups, with the maximum area under the ROC curve and minimum standard error for the ACCI score. Both ACCI and UFGSI are useful for evaluating the prognosis of Fournier's gangrene. However, ACCI is even better for its higher sensitivity and specificity and easier clinical collection.

  14. MRI-based radiologic scoring system for extent of brain injury in children with hemiplegia.

    Science.gov (United States)

    Shiran, S I; Weinstein, M; Sirota-Cohen, C; Myers, V; Ben Bashat, D; Fattal-Valevski, A; Green, D; Schertz, M

    2014-12-01

    Brain MR imaging is recommended in children with cerebral palsy. Descriptions of MR imaging findings lack uniformity, due to the absence of a validated quantitative approach. We developed a quantitative scoring method for brain injury based on anatomic MR imaging and examined the reliability and validity in correlation to motor function in children with hemiplegia. Twenty-seven children with hemiplegia underwent MR imaging (T1, T2-weighted sequences, DTI) and motor assessment (Manual Ability Classification System, Gross Motor Functional Classification System, Assisting Hand Assessment, Jebsen Taylor Test of Hand Function, and Children's Hand Experience Questionnaire). A scoring system devised in our center was applied to all scans. Radiologic score covered 4 domains: number of affected lobes, volume and type of white matter injury, extent of gray matter damage, and major white matter tract injury. Inter- and intrarater reliability was evaluated and the relationship between radiologic score and motor assessments determined. Mean total radiologic score was 11.3 ± 4.5 (range 4-18). Good inter- (ρ = 0.909, P classification systems (ρ = 0.708, P high inter- and intrarater reliability and significant associations with manual ability classification systems and motor evaluations. This score provides a standardized radiologic assessment of brain injury extent in hemiplegic patients with predominantly unilateral injury, allowing comparison between groups, and providing an additional tool for counseling families. © 2014 by American Journal of Neuroradiology.

  15. Donor funding health policy and systems research in low- and middle-income countries: how much, from where and to whom.

    Science.gov (United States)

    Grépin, Karen Ann; Pinkstaff, Crossley Beth; Shroff, Zubin Cyrus; Ghaffar, Abdul

    2017-08-31

    The need for sufficient and reliable funding to support health policy and systems research (HPSR) in low- and middle-income countries (LMICs) has been widely recognised. Currently, most resources to support such activities come from traditional development assistance for health (DAH) donors; however, few studies have examined the levels, trends, sources and national recipients of such support - a gap this research seeks to address. Using OECD's Creditor Reporting System database, we classified donor funding commitments using a keyword analysis of the project-level descriptions of donor supported projects to estimate total funding available for HPSR-related activities annually from bilateral and multilateral donors, as well as the Bill and Melinda Gates Foundation, to LMICs over the period 2000-2014. Total commitments to HPSR-related activities have greatly increased since 2000, peaked in 2010, and have held steady since 2011. Over the entire study period (2000-2014), donors committed a total of $4 billion in funding for HPSR-related activities or an average of $266 million a year. Over the last 5 years (2010-2014), donors committed an average of $434 million a year to HPSR-related activities. Funding for HPSR is heavily concentrated, with more than 93% coming from just 10 donors and only represents approximately 2% of all donor funding for health and population projects. Countries in the sub-Saharan African region are the major recipients of HPSR funding. Funding for HPSR-related activities has generally increased over the study period; however, donor support to such activities represents only a small proportion of total DAH and has not grown in recent years. Donors should consider increasing the proportion of funds they allocate to support HPSR activities in order to further build the evidence base on how to build stronger health systems.

  16. Hand-made cloned goat (Capra hircus) embryos—a comparison of different donor cells and culture systems.

    Science.gov (United States)

    Akshey, Yogesh S; Malakar, Dhruba; De, Arun K; Jena, Manoj K; Garg, Shweta; Dutta, Rahul; Pawar, Sachin Kumar; Mukesh, Manisha

    2010-10-01

    Nuclear transfer is a very effective method for propagation of valuable, extinct, and endangered animals. Hand-made cloning (HMC) is an efficient alternative to the conventional micromanipulator-based technique in some domestic species. The present study was carried out for the selection of suitable somatic cells as a nuclear donor and development of an optimum culture system for in vitro culture of zona-free goat cloned embryos. Cleavage and blastocyst rates were observed 72.06 ± 2.94% and 0% for fresh cumulus cells, 81.95 ± 3.40% and 12.74 ± 2.12% for cultured cumulus cells, and 92.94 ± 0.91% and 23.78 ± 3.33% for fetal fibroblast cells, respectively. There was a significant (p cloned embryos and donor cells. In conclusion, the present study describes that the fetal fibroblast cell is a suitable candidate as nuclear donor, and the flat surface culture system is suitable for zona-free blastocyst development by the hand-made cloning technique in the goat.

  17. The OMERACT psoriatic arthritis magnetic resonance imaging scoring system (PsAMRIS): definitions of key pathologies, suggested MRI sequences, and preliminary scoring system for PsA Hands

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; McQueen, Fiona; Wiell, Charlotte

    2009-01-01

    This article describes a preliminary OMERACT psoriatic arthritis magnetic resonance image scoring system (PsAMRIS) for evaluation of inflammatory and destructive changes in PsA hands, which was developed by the international OMERACT MRI in inflammatory arthritis group. MRI definitions of important...... pathologies in peripheral PsA and suggestions concerning appropriate MRI sequences for use in PsA hands are also provided....

  18. Total hip arthroplasty outcomes assessment using functional and radiographic scores to compare canine systems.

    Science.gov (United States)

    Iwata, D; Broun, H C; Black, A P; Preston, C A; Anderson, G I

    2008-01-01

    A retrospective multi-centre study was carried out in order to compare outcomes between cemented and uncemented total hip arthoplasties (THA). A quantitative orthopaedic outcome assessment scoring system was devised in order to relate functional outcome to a numerical score, to allow comparison between treatments and amongst centres. The system combined a radiographic score and a clinical score. Lower scores reflect better outcomes than higher scores. Consecutive cases of THA were included from two specialist practices between July 2002 and December 2005. The study included 46 THA patients (22 uncemented THA followed for 8.3 +/- 4.7M and 24 cemented THA for 26.0 +/- 15.7M) with a mean age of 4.4 +/- 3.3 years at surgery. Multi-variable linear and logistical regression analyses were performed with adjustments for age at surgery, surgeon, follow-up time, uni- versus bilateral disease, gender and body weight. The differences between treatment groups in terms of functional scores or total scores were not significant (p > 0.05). Radiographic scores were different between treatment groups. However, these scores were usually assessed within two months of surgery and proved unreliable predictors of functional outcome (p > 0.05). The findings reflect relatively short-term follow-up, especially for the uncemented group, and do not include clinician-derived measures, such as goniometry and thigh circumference. Longer-term follow-up for the radiographic assessments is essential. A prospective study including the clinician-derived outcomes needs to be performed in order to validate the outcome instrument in its modified form.

  19. Simple Scoring System to Predict In-Hospital Mortality After Surgery for Infective Endocarditis.

    Science.gov (United States)

    Gatti, Giuseppe; Perrotti, Andrea; Obadia, Jean-François; Duval, Xavier; Iung, Bernard; Alla, François; Chirouze, Catherine; Selton-Suty, Christine; Hoen, Bruno; Sinagra, Gianfranco; Delahaye, François; Tattevin, Pierre; Le Moing, Vincent; Pappalardo, Aniello; Chocron, Sidney

    2017-07-20

    Aspecific scoring systems are used to predict the risk of death postsurgery in patients with infective endocarditis (IE). The purpose of the present study was both to analyze the risk factors for in-hospital death, which complicates surgery for IE, and to create a mortality risk score based on the results of this analysis. Outcomes of 361 consecutive patients (mean age, 59.1±15.4 years) who had undergone surgery for IE in 8 European centers of cardiac surgery were recorded prospectively, and a risk factor analysis (multivariable logistic regression) for in-hospital death was performed. The discriminatory power of a new predictive scoring system was assessed with the receiver operating characteristic curve analysis. Score validation procedures were carried out. Fifty-six (15.5%) patients died postsurgery. BMI >27 kg/m 2 (odds ratio [OR], 1.79; P =0.049), estimated glomerular filtration rate 55 mm Hg (OR, 1.78; P =0.032), and critical state (OR, 2.37; P =0.017) were independent predictors of in-hospital death. A scoring system was devised to predict in-hospital death postsurgery for IE (area under the receiver operating characteristic curve, 0.780; 95% CI, 0.734-0.822). The score performed better than 5 of 6 scoring systems for in-hospital death after cardiac surgery that were considered. A simple scoring system based on risk factors for in-hospital death was specifically created to predict mortality risk postsurgery in patients with IE. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  20. Do Scoring Systems Help in Predicting Survival Following Ruptured Abdominal Aortic Aneurysm Surgery?

    Science.gov (United States)

    Gatt, Marcel; Goldsmith, Paul; Martinez, Marcos; Barandiaran, Jesus; Grover, Kartikae; El-Barghouti, Naif; Perry, Eugene P

    2009-01-01

    INTRODUCTION The aim of this study was to assess the value of the Hardman Index and the Glasgow Aneurysm Score in predicting postoperative mortality in patients with ruptured abdominal aortic aneurysm (rAAA), and to assess the correlation between the two. PATIENTS AND METHODS Patients admitted with rAAA were identified from a hospital database. Hospital records were reviewed and a retrospective Hardman Index and Glasgow Aneurysm Score was calculated. Poor postoperative prognosis was considered at a Glasgow Aneurysm Score > 95 or a Hardman Index ≥ 3. RESULTS A total of 96 patients with a median age of 77.5 years (interquartile range, 71–83 years) and a male:female ratio of 2:1 were identified. Of these, 37 patients were not offered surgery and this was associated with 100% mortality. Of the 59 operated patients, 36 (61%) patients died postoperatively. Operated patients had a median Glasgow Aneurysm Score of 91 (interquartile range, 77–101) and a Hardman Index of 2 (interquartile range, 1–2). In this group, a Glasgow Aneurysm Score > 95 or a Hardman Index ≥ 3 was not associated with mortality (P = 0.10 and P = 0.79, respectively). Correlation between the scoring systems was poor (+0.42 τb). CONCLUSIONS The scoring systems assessed did not help predict the outcome of rAAA surgery, and correlated poorly with each other. They do not aid clinical judgement. PMID:19102824

  1. MRI assessment of knee osteoarthritis: Knee Osteoarthritis Scoring System (KOSS) - inter-observer and intra-observer reproducibility of a compartment-based scoring system

    International Nuclear Information System (INIS)

    Kornaat, Peter R.; Ceulemans, Ruth Y.T.; Kroon, Herman M.; Bloem, Johan L.; Riyazi, Naghmeh; Kloppenburg, Margreet; Carter, Wayne O.; Woodworth, Thasia G.

    2005-01-01

    To develop a scoring system for quantifying osteoarthritic changes of the knee as identified by magnetic resonance (MR) imaging, and to determine its inter- and intra-observer reproducibility, in order to monitor medical therapy in research studies. Two independent observers evaluated 25 consecutive MR examinations of the knee in patients with previously defined clinical symptoms and radiological signs of osteoarthritis. We acquired on a 1.5 T system: coronal and sagittal proton density- and T2-weighted dual spin echo (SE) images, sagittal three-dimensional T1-weighted gradient echo (GE) images with fat suppression, and axial dual turbo SE images with fat suppression. Images were scored for the presence of cartilaginous lesions, osteophytes, subchondral cysts, bone marrow edema, and for meniscal abnormalities. Presence and size of effusion, synovitis and Baker's cyst were recorded. All parameters were ranked on a previously defined, semiquantitative scale, reflecting increasing severity of findings. Kappa, weighted kappa and intraclass correlation coefficient (ICC) were used to determine inter- and intra-observer variability. Inter-observer reproducibility was good (ICC value 0.77). Inter- and intra-observer reproducibility for individual parameters was good to very good (inter-observer ICC value 0.63-0.91; intra-observer ICC value 0.76-0.96). The presented comprehensive MR scoring system for osteoarthritic changes of the knee has a good to very good inter-observer and intra-observer reproducibility. Thus the score form with its definitions can be used for standardized assessment of osteoarthritic changes to monitor medical therapy in research studies. (orig.)

  2. Analysis of Four Scoring Systems for the Prognosis of Patients with Metastasis of the Vertebral Column.

    Science.gov (United States)

    Pollner, Péter; Horváth, Anna; Mezei, Tamás; Banczerowski, Péter; Czigléczki, Gábor

    2018-04-01

    Metastatic spinal diseases are common health problems and there is no consensus on the appropriate treatment of metastases in several conditions. Using clinical measures (e.g., survival time and functional status), prognosis prediction systems advise on the appropriate interventions. The aim of this article is to assess and compare 4 widely used scoring systems (revised Tokuhashi, Tomita, van der Linden, and modified Bauer scores) on a single-center cohort. A retrospective study was designed of 329 patients who were subjected to surgery because of metastatic spinal diseases. Subpopulations according to the classifications of the 4 scoring systems were identified. The overall survival was calculated with the Kaplan-Meier formula. The difference between the survival curves of subpopulations was analyzed with log-rank tests. The consistency rates for the 4 scoring systems are calculated as well. The follow-up period was 8 years. The median survival time was 222 days. The overall survival of prognostic categories in 3 scoring systems was significantly different from each other, but we found no differences between the categories of the van der Linden system. In this cohort, the revised Tokuhashi system gave the best approximation for survival, with a mean predictive capability 60.5%. The evaluation of 4 standard scoring systems showed that 3 were self-consistent, although none of systems was able to predict the survival in our cohort. Based on the predictive capability, the revised Tokuhashi system may provide the best predictions with careful examination of individual cases. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. The Use of an Enhanced Polygraph Scoring Technique in Homeland Security: The Empirical Scoring System-Making a Difference

    Science.gov (United States)

    2012-03-01

    confidence rating (p value) (Macmillan, & Creelman , 1996). More specifically, as response bias relates to polygraph scoring, the development of the...Macmillan, N., & Creelman , C. (1996). Triangles in ROC space: History and theory of “nonparametric” measures of sensitivity and response bias

  4. Assessing the repeatability and reproducibility of the Leg Score: a Dutch Claw Health Scoring System for dairy cattle

    NARCIS (Netherlands)

    Holzhauer, M.; Middelesch, H.; Bartels, C.J.; Frankena, K.; Verhoeff, J.; Noordhuizen-Stassen, E.N.; Noordhuizen, J.P.T.M.

    2005-01-01

    The optimal moment for trimming the claws of all dairy cows in a herd was investigated by assessing the external rotation of the hind claws of individual cows relative to the spinal column. This leg score consisted of three independent descriptors: 1 (good/ normal), 2 (moderately deviant), and 3

  5. The evaluation of CRIB II scoring system in predicting mortality in preterm newborns

    Directory of Open Access Journals (Sweden)

    Homa Babaei

    2015-02-01

    Full Text Available Background: The survival rate of premature newborns depends on gestational age, birth weight and condition when they are hospitalized. Different scoring systems to predict mortality in newborns has been designed. The purpose of this study was to evaluate value of CRIB II scoring system in predicting mortality rate of infants with birth weights less than 1500 grams. Material and Methods: In this 8 month cross - sectional study (September 2010 to April 2010 which was conducted in the NICU of Imam Reza hospital in Kermanshah, preterm newborns with birth weight less than 1500 gr and gestational age less than 32 weeks who were admitted within 12 hours after birth in the NICU ,were evaluated based on CRIB II scoring system . Results: 50 neonates out of 1360 (36.8% survived and 86 neonates(63.2% died. Average CRIB II score in newborn survived was 5.8±2.9 and in infants died was 9.8±2.9 (p <0.0001. Based on the AUC, the CRIB II score could predict about 0.85 (CI: 0.77-0.92 of mortality. Also based on the ROC curve cut-off point for scoring CRIB II, was 6.5. Conclusion: Our study showed that CRIB II has a high value( about %85 in predicting mortality in newborns with birth weights less than 1500 grams.

  6. Validating severity of illness scoring systems in the prediction of outcomes in Staphylococcus aureus bacteremia.

    Science.gov (United States)

    Sharma, Mamta; Szpunar, Susan; Khatib, Riad

    2013-08-01

    Severity of illness scores are helpful in predicting mortality; however, no standardized scoring system has been validated in patients with Staphylococcus aureus bacteremia (SAB). The modified Rapid Emergency Medicine Score (REMS), the CURB-65 (confusion, urea, respiratory rate, blood pressure and age 65) and the Charlson weighted index of comorbidity (CWIC) were compared in predicting outcomes at the onset of SAB. All adult inpatients with SAB from July 15, 2008, to December 31, 2009, were prospectively assessed. The 3 scoring systems were applied: REMS, CURB-65 and CWIC. The end points were attributable and overall mortality. A total of 241 patients with SAB were reviewed during the study period. The all-cause mortality rate was 22.8% and attributable mortality 14.1%. Patients who died had higher mean CURB-65 score and REMS than those who lived, whereas the difference in the CWIC score was not significant. Two logistic regression models based on CURB-65 score or REMS, after controlling for CWIC, revealed that both scores were independent predictors of mortality, with an odds ratio of 3.38 (P < 0.0001) and 1.45 (P < 0.0001) for CURB-65 and REMS, respectively. Receiver operating characteristic analysis revealed that a cutoff point of 3.0 (CURB-65) and 6.0 (REMS) provided the highest sensitivity and specificity. The area under the curves for all-cause mortality were 0.832 and 0.806, and for attributable mortality 0.845 and 0.819, for CURB-65 and REMS, respectively. REMS and CURB-65 scores outperformed CWIC as predictors of mortality in SAB and may be effective in predicting the severity of illness at the onset of bacteremia.

  7. Developing points-based risk-scoring systems in the presence of competing risks.

    Science.gov (United States)

    Austin, Peter C; Lee, Douglas S; D'Agostino, Ralph B; Fine, Jason P

    2016-09-30

    Predicting the occurrence of an adverse event over time is an important issue in clinical medicine. Clinical prediction models and associated points-based risk-scoring systems are popular statistical methods for summarizing the relationship between a multivariable set of patient risk factors and the risk of the occurrence of an adverse event. Points-based risk-scoring systems are popular amongst physicians as they permit a rapid assessment of patient risk without the use of computers or other electronic devices. The use of such points-based risk-scoring systems facilitates evidence-based clinical decision making. There is a growing interest in cause-specific mortality and in non-fatal outcomes. However, when considering these types of outcomes, one must account for competing risks whose occurrence precludes the occurrence of the event of interest. We describe how points-based risk-scoring systems can be developed in the presence of competing events. We illustrate the application of these methods by developing risk-scoring systems for predicting cardiovascular mortality in patients hospitalized with acute myocardial infarction. Code in the R statistical programming language is provided for the implementation of the described methods. © 2016 The Authors. Statistics in Medicine published by John Wiley & Sons Ltd. © 2016 The Authors. Statistics in Medicine published by John Wiley & Sons Ltd.

  8. 76 FR 10047 - Changes to the Public Housing Assessment System (PHAS): Financial Condition Scoring Notice

    Science.gov (United States)

    2011-02-23

    ... accepted accounting principles (GAAP)-based financial information. This notice updates and clarifies the... Housing Assessment System (PHAS): Financial Condition Scoring Notice AGENCY: Office of the Assistant... under the financial condition indicator of the Public Housing Assessment System (PHAS). This notice...

  9. Evaluation of a prospective scoring system designed for a multicenter breast MR imaging screening study.

    Science.gov (United States)

    Warren, Ruth M L; Thompson, Deborah; Pointon, Linda J; Hoff, Rebecca; Gilbert, Fiona J; Padhani, Anwar R; Easton, Douglas F; Lakhani, Sunil R; Leach, Martin O

    2006-06-01

    To evaluate prospectively the accuracy of a lesion classification system designed for use in a magnetic resonance (MR) imaging high-breast-cancer-risk screening study. All participating patients provided written informed consent. Ethics committee approval was obtained. The results of 1541 contrast material-enhanced breast MR imaging examinations were analyzed; 1441 screening examinations were performed in 638 women aged 24-51 years at high risk for breast cancer, and 100 examinations were performed in 100 women aged 23-81 years. Lesion analysis was performed in 991 breasts, which were divided into design (491 breasts) and testing (500 breasts) sets. The reference standard was histologic analysis of biopsy samples, fine-needle aspiration cytology, or minimal follow-up of 24 months. The scoring system involved the use of five features: morphology (MOR), pattern of enhancement (POE), percentage of maximal focal enhancement (PMFE), maximal signal intensity-time ratio (MITR), and pattern of contrast material washout (POCW). The system was evaluated by means of (a) assessment of interreader agreement, as expressed in kappa statistics, for 315 breasts in which both readers analyzed the same lesion, (b) assessment of the diagnostic accuracy of the scored components with receiver operating characteristic curve analysis, and (c) logistic regression analysis to determine which components of the scoring system were critical to the final score. A new simplified scoring system developed with the design set was applied to the testing set. There was moderate reader agreement regarding overall lesion outcome (ie, malignant, suspicious, or benign) (kappa=0.58) and less agreement regarding the scored components. The area under the receiver operating characteristic curve (AUC) for the overall lesion score, 0.88, was higher than the AUC for any one component. The components MOR, POE, and POCW yielded the best overall result. PMFE and MITR did not contribute to diagnostic utility

  10. Cervical injuries scored according to the Subaxial Injury Classification system: An analysis of the literature

    Directory of Open Access Journals (Sweden)

    Andrei F Joaquim

    2014-01-01

    Full Text Available Introduction: The Subaxial Injury Classification (SLIC system and severity score has been developed to help surgeons in the decision-making process of treatment of subaxial cervical spine injuries. A detailed description of all potential scored injures of the SLIC is lacking. Materials and Methods: We performed a systematic review in the PubMed database from 2007 to 2014 to describe the relationship between the scored injuries in the SLIC and their eventual treatment according to the system score. Results: Patients with an SLIC of 1-3 points (conservative treatment are neurologically intact with the spinous process, laminar or small facet fractures. Patients with compression and burst fractures who are neurologically intact are also treated nonsurgically. Patients with an SLIC of 4 points may have an incomplete spinal cord injury such as a central cord syndrome, compression injuries with incomplete neurologic deficits and burst fractures with complete neurologic deficits. SLIC of 5-10 points includes distraction and rotational injuries, traumatic disc herniation in the setting of a neurological deficit and burst fractures with an incomplete neurologic deficit. Conclusion: The SLIC injury severity score can help surgeons guide fracture treatment. Knowledge of the potential scored injures and their relationships with the SLIC are of paramount importance for spine surgeons who treated subaxial cervical spine injuries.

  11. Interobserver Reliability of the Total Body Score System for Quantifying Human Decomposition.

    Science.gov (United States)

    Dabbs, Gretchen R; Connor, Melissa; Bytheway, Joan A

    2016-03-01

    Several authors have tested the accuracy of the Total Body Score (TBS) method for quantifying decomposition, but none have examined the reliability of the method as a scoring system by testing interobserver error rates. Sixteen participants used the TBS system to score 59 observation packets including photographs and written descriptions of 13 human cadavers in different stages of decomposition (postmortem interval: 2-186 days). Data analysis used a two-way random model intraclass correlation in SPSS (v. 17.0). The TBS method showed "almost perfect" agreement between observers, with average absolute correlation coefficients of 0.990 and average consistency correlation coefficients of 0.991. While the TBS method may have sources of error, scoring reliability is not one of them. Individual component scores were examined, and the influences of education and experience levels were investigated. Overall, the trunk component scores were the least concordant. Suggestions are made to improve the reliability of the TBS method. © 2016 American Academy of Forensic Sciences.

  12. Determining utility values in patients with anterior cruciate ligament tears using clinical scoring systems

    Directory of Open Access Journals (Sweden)

    Szucs Thomas

    2011-08-01

    Full Text Available Abstract Background Several instruments and clinical scoring systems have been established to evaluate patients with ligamentous knee injuries. A comparison of individual articles in the literature is challenging, not only because of heterogeneity in methodology, but also due to the variety of the scoring systems used to document clinical outcomes. There is limited information about the correlation between used scores and quality of life with no information being available on the impact of each score on the utility values. The aim of this study was to compare the most commonly used scores for evaluating patients with anterior cruciate ligament (ACL injuries, and to establish corresponding utility values. These values will be used for the interpretation and comparison of outcome results in the currently available literature for different treatment options. Methods Four hypothetical vignettes were defined, based on different levels of activities after rupture of the ACL to simulate typical situations seen in daily practice. A questionnaire, including the Health Utility Index (HUI for utility values, the IKDC subjective score, the Lysholm and the Tegner score, was created and 25 orthopedic surgeons were asked to fill the questionnaire for each hypothetical patient as proxies for all patients they had treated and who would fit in that hypothetical vignette. Results The utility value as an indicator for quality of life increased with the level of activity. Having discomforts already during normal activities of daily living was rated with a mean utility value of 0.37 ± 0.19, half of that of a situation where mild sport activity was possible without discomfort (0.78 ± 0.11. All investigated scores were able to distinguish clearly (p Conclusions Here we report the correlation between the most commonly used scores for the assessment of patients with a ruptured ACL and utility values as an indicator of quality of life. Assumptions were based on expert

  13. Timely diagnosis of dairy calf respiratory disease using a standardized scoring system.

    Science.gov (United States)

    McGuirk, Sheila M; Peek, Simon F

    2014-12-01

    Respiratory disease of young dairy calves is a significant cause of morbidity, mortality, economic loss, and animal welfare concern but there is no gold standard diagnostic test for antemortem diagnosis. Clinical signs typically used to make a diagnosis of respiratory disease of calves are fever, cough, ocular or nasal discharge, abnormal breathing, and auscultation of abnormal lung sounds. Unfortunately, routine screening of calves for respiratory disease on the farm is rarely performed and until more comprehensive, practical and affordable respiratory disease-screening tools such as accelerometers, pedometers, appetite monitors, feed consumption detection systems, remote temperature recording devices, radiant heat detectors, electronic stethoscopes, and thoracic ultrasound are validated, timely diagnosis of respiratory disease can be facilitated using a standardized scoring system. We have developed a scoring system that attributes severity scores to each of four clinical parameters; rectal temperature, cough, nasal discharge, ocular discharge or ear position. A total respiratory score of five points or higher (provided that at least two abnormal parameters are observed) can be used to distinguish affected from unaffected calves. This can be applied as a screening tool twice-weekly to identify pre-weaned calves with respiratory disease thereby facilitating early detection. Coupled with effective treatment protocols, this scoring system will reduce post-weaning pneumonia, chronic pneumonia, and otitis media.

  14. Correlations between skin blood perfusion values and nailfold capillaroscopy scores in systemic sclerosis patients.

    Science.gov (United States)

    Ruaro, B; Sulli, A; Pizzorni, C; Paolino, S; Smith, V; Cutolo, M

    2016-05-01

    To correlate blood perfusion (BP) values assessed by laser speckle contrast analysis (LASCA) in selected skin areas of hands and face with nailfold capillary damage scores in systemic sclerosis (SSc) patients. Seventy SSc patients (mean SSc duration 6 ± 5 years) and 70 volunteer healthy subjects were enrolled after informed consent. LASCA was performed at different areas of the face (forehead, tip of nose, zygomas and perioral region) and at dorsal and volar regions of hands. Microvascular damage was assessed and scored by nailfold videocapillaroscopy (NVC) and the microangiopathy evolution score (MES) was calculated. SSc patients showed a significantly lower BP than healthy subjects at fingertips, periungual areas and palm of hands (pnailfold capillaroscopy scores of microangiopathy. Copyright © 2016. Published by Elsevier Inc.

  15. Comparison of risk scoring systems for patients presenting with upper gastrointestinal bleeding

    DEFF Research Database (Denmark)

    Stanley, Adrian J; Laine, Loren; Dalton, Harry R

    2017-01-01

    OBJECTIVE: To compare the predictive accuracy and clinical utility of five risk scoring systems in the assessment of patients with upper gastrointestinal bleeding. DESIGN: International multicentre prospective study. SETTING: Six large hospitals in Europe, North America, Asia, and Oceania...... clinical endpoints: a composite endpoint (transfusion, endoscopic treatment, interventional radiology, surgery, or 30 day mortality), endoscopic treatment, 30 day mortality, rebleeding, and length of hospital stay. Optimum score thresholds to identify low risk and high risk patients were determined...... accuracy at predicting need for hospital based intervention or death. Scores of ≤1 appear the optimum threshold for directing patients to outpatient management. AUROCs of scores for the other endpoints are less than 0.80, therefore their clinical utility for these outcomes seems to be limited...

  16. A new pathological scoring system by the Japanese classification to predict renal outcome in diabetic nephropathy.

    Science.gov (United States)

    Hoshino, Junichi; Furuichi, Kengo; Yamanouchi, Masayuki; Mise, Koki; Sekine, Akinari; Kawada, Masahiro; Sumida, Keiichi; Hiramatsu, Rikako; Hasegawa, Eiko; Hayami, Noriko; Suwabe, Tatsuya; Sawa, Naoki; Hara, Shigeko; Fujii, Takeshi; Ohashi, Kenichi; Kitagawa, Kiyoki; Toyama, Tadashi; Shimizu, Miho; Takaichi, Kenmei; Ubara, Yoshifumi; Wada, Takashi

    2018-01-01

    The impact of the newly proposed pathological classification by the Japan Renal Pathology Society (JRPS) on renal outcome is unclear. So we evaluated that impact and created a new pathological scoring to predict outcome using this classification. A multicenter cohort of 493 biopsy-proven Japanese patients with diabetic nephropathy (DN) were analyzed. The association between each pathological factor-Tervaert' and JRPS classifications-and renal outcome (dialysis initiation or 50% eGFR decline) was estimated by adjusted Cox regression. The overall pathological risk score (J-score) was calculated, whereupon its predictive ability for 10-year risk of renal outcome was evaluated. The J-scores of diffuse lesion classes 2 or 3, GBM doubling class 3, presence of mesangiolysis, polar vasculosis, and arteriolar hyalinosis were, respectively, 1, 2, 4, 1, and 2. The scores of IFTA classes 1, 2, and 3 were, respectively, 3, 4, and 4, and those of interstitial inflammation classes 1, 2, and 3 were 5, 5, and 4 (J-score range, 0-19). Renal survival curves, when dividing into four J-score grades (0-5, 6-10, 11-15, and 16-19), were significantly different from each other (prenal outcome. Ability to predict 10-year renal outcome was improved when the J-score was added to the basic model: c-statistics from 0.661 to 0.685; category-free net reclassification improvement, 0.154 (-0.040, 0.349, p = 0.12); and integrated discrimination improvement, 0.015 (0.003, 0.028, p = 0.02). Mesangiolysis, polar vasculosis, and doubling of GBM-features of the JRPS system-were significantly associated with renal outcome. Prediction of DN patients' renal outcome was better with the J-score than without it.

  17. [Results of applying a paediatric early warning score system as a healthcare quality improvement plan].

    Science.gov (United States)

    Rivero-Martín, M J; Prieto-Martínez, S; García-Solano, M; Montilla-Pérez, M; Tena-Martín, E; Ballesteros-García, M M

    2016-06-01

    The aims of this study were to introduce a paediatric early warning score (PEWS) into our daily clinical practice, as well as to evaluate its ability to detect clinical deterioration in children admitted, and to train nursing staff to communicate the information and response effectively. An analysis was performed on the implementation of PEWS in the electronic health records of children (0-15 years) in our paediatric ward from February 2014 to September 2014. The maximum score was 6. Nursing staff reviewed scores >2, and if >3 medical and nursing staff reviewed it. Monitoring indicators: % of admissions with scoring; % of complete data capture; % of scores >3; % of scores >3 reviewed by medical staff, % of changes in treatment due to the warning system, and number of patients who needed Paediatric Intensive Care Unit (PICU) admission, or died without an increased warning score. The data were collected from all patients (931) admitted. The scale was measured 7,917 times, with 78.8% of them with complete data capture. Very few (1.9%) showed scores >3, and 14% of them with changes in clinical management (intensifying treatment or new diagnostic tests). One patient (scored 2) required PICU admission. There were no deaths. Parents or nursing staff concern was registered in 80% of cases. PEWS are useful to provide a standardised assessment of clinical status in the inpatient setting, using a unique scale and implementing data capture. Because of the lack of severe complications requiring PICU admission and deaths, we will have to use other data to evaluate these scales. Copyright © 2016 SECA. Published by Elsevier Espana. All rights reserved.

  18. Encapsulation of ropivacaine in a combined (donor-acceptor, ionic-gradient liposomal system promotes extended anesthesia time.

    Directory of Open Access Journals (Sweden)

    Camila Morais Gonçalves da Silva

    Full Text Available Ropivacaine is a local anesthetic with similar potency but lower systemic toxicity than bupivacaine, the most commonly used spinal anesthetic. The present study concerns the development of a combined drug delivery system for ropivacaine, comprised of two types of liposomes: donor multivesicular vesicles containing 250 mM (NH42SO4 plus the anesthetic, and acceptor large unilamellar vesicles with internal pH of 5.5. Both kinds of liposomes were composed of hydrogenated soy-phosphatidylcholine:cholesterol (2:1 mol% and were prepared at pH 7.4. Dynamic light scattering, transmission electron microscopy and electron paramagnetic resonance techniques were used to characterize the average particle size, polydispersity, zeta potential, morphology and fluidity of the liposomes. In vitro dialysis experiments showed that the combined liposomal system provided significantly longer (72 h release of ropivacaine, compared to conventional liposomes (~45 h, or plain ropivacaine (~4 h (p <0.05. The pre-formulations tested were significantly less toxic to 3T3 cells, with toxicity increasing in the order: combined system < ropivacaine in donor or acceptor liposomes < ropivacaine in conventional liposomes < plain ropivacaine. The combined formulation, containing 2% ropivacaine, increased the anesthesia duration up to 9 h after subcutaneous infiltration in mice. In conclusion, a promising drug delivery system for ropivacaine was described, which can be loaded with large amounts of the anesthetic (2%, with reduced in vitro cytotoxicity and extended anesthesia time.

  19. The SPOTS System: An Ocular Scoring System Optimized for Use in Modern Preclinical Drug Development and Toxicology.

    Science.gov (United States)

    Eaton, Joshua Seth; Miller, Paul E; Bentley, Ellison; Thomasy, Sara M; Murphy, Christopher J

    2017-12-01

    To present a semiquantitative ocular scoring system comprising elements and criteria that address many of the limitations associated with systems commonly used in preclinical studies, providing enhanced cross-species applicability and predictive value in modern ocular drug and device development. Revisions to the ocular scoring systems of McDonald-Shadduck and Hackett-McDonald were conducted by board-certified veterinary ophthalmologists at Ocular Services On Demand (OSOD) over the execution of hundreds of in vivo preclinical ocular drug and device development studies and general toxicological investigations. This semiquantitative preclinical ocular toxicology scoring (SPOTS) system was driven by limitations of previously published systems identified by our group's recent review of slit lamp-based scoring systems in clinical ophthalmology, toxicology, and vision science. The SPOTS system provides scoring criteria for the anterior segment, posterior segment, and characterization of intravitreal test articles. Key elements include: standardized slit lamp settings; expansion of criteria to enhance applicability to nonrabbit species; refinement and disambiguation of scoring criteria for corneal opacity, fluorescein staining severity, and aqueous flare; introduction of novel criteria for scoring of aqueous and anterior vitreous cell; and introduction of criteria for findings observed with drugs/devices targeting the posterior segment. A modified Standardization of Uveitis Nomenclature (SUN) system is also introduced to facilitate accurate use of SUN's criteria in laboratory species. The SPOTS systems provide criteria that stand to enhance the applicability of semiquantitative scoring criteria to the full range of laboratory species, in the context of modern approaches to ocular therapeutics and drug delivery and drug and device development.

  20. PyParse: a semiautomated system for scoring spoken recall data.

    Science.gov (United States)

    Solway, Alec; Geller, Aaron S; Sederberg, Per B; Kahana, Michael J

    2010-02-01

    Studies of human memory often generate data on the sequence and timing of recalled items, but scoring such data using conventional methods is difficult or impossible. We describe a Python-based semiautomated system that greatly simplifies this task. This software, called PyParse, can easily be used in conjunction with many common experiment authoring systems. Scored data is output in a simple ASCII format and can be accessed with the programming language of choice, allowing for the identification of features such as correct responses, prior-list intrusions, extra-list intrusions, and repetitions.

  1. A Comparison of Systemic Inflammation-Based Prognostic Scores in Patients on Regular Hemodialysis

    Directory of Open Access Journals (Sweden)

    Akihiko Kato

    2013-10-01

    Full Text Available Background/Aims: Systemic inflammation-based prognostic scores have prognostic power in patients with cancer, independently of tumor stage and site. Although inflammatory status is associated with mortality in hemodialysis (HD patients, it remains to be determined as to whether these composite scores are useful in predicting clinical outcomes. Methods: We calculated the 6 prognostic scores [Glasgow prognostic score (GPS, modified GPS (mGPS, neutrophil-lymphocyte ratio (NLR, platelet lymphocyte ratio (PLR, prognostic index (PI and prognostic nutritional index (PNI], which have been established as a useful scoring system in cancer patients. We enrolled 339 patients on regular HD (age: 64 ± 13 years; time on HD: 129 ± 114 months; males/females = 253/85 and followed them for 42 months. The area under the receiver-operating characteristics curve was used to determine which scoring system was more predictive of mortality. Results: Elevated GPS, mGPS, NLR, PLR, PI and PNI were all associated with total mortality, independent of covariates. If GPS was raised, mGPS, NLR, PLR and PI were also predictive of all-cause mortality and/or hospitalization. GPS and PNI were associated with poor nutritional status. Using overall mortality as an endpoint, the area under the curve (AUC was significant for a GPS of 0.701 (95% CI: 0.637-0.765; p Conclusion: GPS, based on serum albumin and highly sensitive C-reactive protein, has the most prognostic power for mortality prediction among the prognostic scores in HD patients. However, as the determination of serum albumin reflects mortality similarly to GPS, other composite combinations are needed to provide additional clinical utility beyond that of albumin alone in HD patients.

  2. Noninvasive scoring system for significant inflammation related to chronic hepatitis B

    Science.gov (United States)

    Hong, Mei-Zhu; Ye, Linglong; Jin, Li-Xin; Ren, Yan-Dan; Yu, Xiao-Fang; Liu, Xiao-Bin; Zhang, Ru-Mian; Fang, Kuangnan; Pan, Jin-Shui

    2017-03-01

    Although a liver stiffness measurement-based model can precisely predict significant intrahepatic inflammation, transient elastography is not commonly available in a primary care center. Additionally, high body mass index and bilirubinemia have notable effects on the accuracy of transient elastography. The present study aimed to create a noninvasive scoring system for the prediction of intrahepatic inflammatory activity related to chronic hepatitis B, without the aid of transient elastography. A total of 396 patients with chronic hepatitis B were enrolled in the present study. Liver biopsies were performed, liver histology was scored using the Scheuer scoring system, and serum markers and liver function were investigated. Inflammatory activity scoring models were constructed for both hepatitis B envelope antigen (+) and hepatitis B envelope antigen (-) patients. The sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve were 86.00%, 84.80%, 62.32%, 95.39%, and 0.9219, respectively, in the hepatitis B envelope antigen (+) group and 91.89%, 89.86%, 70.83%, 97.64%, and 0.9691, respectively, in the hepatitis B envelope antigen (-) group. Significant inflammation related to chronic hepatitis B can be predicted with satisfactory accuracy by using our logistic regression-based scoring system.

  3. [The scoring system for the risk-stratification in patients with the antiphospholipid syndrome].

    Science.gov (United States)

    Oku, Kenji

    2017-01-01

      Antiphospholipid syndrome (APS) is a clinical disorder characterized by thrombosis and/or pregnancy morbidity in the persistence of the pathogenic autoantibodies, the antiphospholipid antibodies (aPL). Recurernt thrombosis is often observed in patients with APS which requires persistent prophylaxis. However, an uniform prophylactic treatment for APS patients is inadequate and stratification of the thrombotic risks is important as aPL are prevalently observed in other various diseases or elderly population. It is previously known that the multiple positivity or high titre of aPL correlate to the thrombotic events. To progress the stratification of the thrombotic risks and to quantitatively analyze them, antiphospholipid score (aPL-S) and the Global Anti-Phospholipid Syndrome Score (GAPSS) were defined as the scoring-systems. Both of these scoring-systems were raised from the large patient cohort data and either aPL profile classified in detail (aPL-S) or simplified aPL profile with classical thrombotic risk factors (GAPSS) were put into scoring system. They have shown a degree of accuracy in identifying high-risk APS patients, especially those at a high risk of thrombosis. However, there are several areas requiring improvement, or at least that clinicians should be aware of, before these instruments are applied in clinical practice. One such issue is standardisation of the aPL tests, including general testing of phosphatidylserine dependent antiprothrombin antibodies (aPS/PT).

  4. Scoring system for differentiating perforated and non-perforated pediatric appendicitis.

    Science.gov (United States)

    Blumfield, Einat; Yang, Daniel; Grossman, Joshua

    2017-10-01

    Appendicitis is the most common indication for emergency pediatric surgery and its most significant complication is perforation. Perforated appendicitis (PA) may be managed conservatively, whereas non-perforated appendicitis (NP) is managed surgically. Recent studies have shown that ultrasound (US) is effective for differentiating between PA and NP, and does not expose pediatric patients to ionizing radiation. The purpose of this study is to enhance the accuracy of differentiation with a novel scoring system based on clinical, laboratory, and US findings. This retrospective study included 243 patients aged 2-17 years who presented between 2006 and 2013 with surgically proven appendicitis, of whom 60 had perforation. Clinical and laboratory data were collected and US images evaluated by a pediatric radiologist. To create the scoring system, point values were assigned to each parameter. A randomly selected training sample of 137 subjects was used to create a scoring prediction model. The model was tested on the remaining 106 patients. Scores of ≥6, ≥11, and ≥15 yielded specificities of 64, 91, and 99%, and sensitivities of 96, 61, and 29%, respectively (p < 0.001). We have designed a scoring system incorporating clinical, laboratory, and sonographic findings which can differentiate PA from NP with high specificity.

  5. New prognostic factors and scoring system for patients with skeletal metastasis.

    Science.gov (United States)

    Katagiri, Hirohisa; Okada, Rieko; Takagi, Tatsuya; Takahashi, Mitsuru; Murata, Hideki; Harada, Hideyuki; Nishimura, Tetsuo; Asakura, Hirofumi; Ogawa, Hirofumi

    2014-10-01

    The aim of this study was to update a previous scoring system for patients with skeletal metastases, that was proposed by Katagiri et al. in 2005, by introducing a new factor (laboratory data) and analyzing a new patient cohort. Between January 2005 and January 2008, we treated 808 patients with symptomatic skeletal metastases. They were prospectively registered regardless of their treatments, and the last follow-up evaluation was performed in 2012. There were 441 male and 367 female patients with a median age of 64 years. Of these patients, 749 were treated nonsurgically while the remaining 59 underwent surgery for skeletal metastasis. A multivariate analysis was conducted using the Cox proportional hazards model. We identified six significant prognostic factors for survival, namely, the primary lesion, visceral or cerebral metastases, abnormal laboratory data, poor performance status, previous chemotherapy, and multiple skeletal metastases. The first three factors had a larger impact than the remaining three. The prognostic score was calculated by adding together all the scores for individual factors. With a prognostic score of ≥7, the survival rate was 27% at 6 months, and only 6% at 1 year. In contrast, patients with a prognostic score of ≤3 had a survival rate of 91% at 1 year, and 78% at 2 years. Comparing the revised system with the previous one, there was a significantly lower number of wrongly predicted patients using the revised system. This revised scoring system was able to predict the survival rates of patients with skeletal metastases more accurately than the previous system and may be useful for selecting an optimal treatment. © 2014 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  6. Polythiophenes and fullerene derivatives based donor-acceptor system: topography by atomic force microscopy

    International Nuclear Information System (INIS)

    Marcakova, M. L.; Repovsky, D.; Cik, G.; Velic, D.

    2017-01-01

    The goal of this work is to examine the surface of a polythiophene/fullerene film in order to understand the structure. In this work polythiophene is used as electron donor and fullerene-derivative is used as electron acceptor. Atomic force microscopy (AFM), is an ideal method to study surfaces and nanostructures. Surfaces of fullerene C60 , fullerene-derivates PCBM, polythiophene P12 and a mixture of P12 and PCBM are characterized. In all samples, the average roughness, the arithmetical value of divergence from the high of the surface, is determined concluding that P12 and PCBM mix together well and form a film with specific topography. (authors)

  7. Bowel Endometriosis Syndrome: a new scoring system for pelvic organ dysfunction and quality of life.

    Science.gov (United States)

    Riiskjær, M; Egekvist, A G; Hartwell, D; Forman, A; Seyer-Hansen, M; Kesmodel, U S

    2017-09-01

    Is it possible to develop a validated score that can identify women with Bowel Endometriosis Syndrome (BENS) and be used to monitor the effect of medical and surgical treatment? The BENS score can be used to identify women with BENS and to monitor the effect of medical and surgical treatment of women suffering from bowel endometriosis. Endometriosis is a heterogeneous disease with extensive variation in anatomical and clinical presentation, and symptoms do not always correspond to the disease burden. Current endometriosis scoring systems are mainly based on anatomical and surgical findings. The score was developed and validated from a cohort of 525 women with medically or surgically treated bowel endometriosis from Aarhus and Copenhagen University Hospitals, Denmark. Patients filled in questionnaires on pelvic pain, quality of life (QoL) and urinary, sexual and bowel function. Items were selected for the final score using clinical and statistical criteria. The chosen variables were included in a multivariate analysis. Individual score values were designated items to form the BENS score, which was divided into 'no BENS', 'minor BENS' and 'major BENS.' Internal and external validations were performed. The six most important items were 'pelvic pain', 'use of analgesics', 'dyschezia', 'straining to urinate', 'fecal urgency' and 'satisfaction with sexual life'. The range of the BENS score (0-28) was divided into 0-8 (no BENS), 9-16 (minor BENS) and 17-28 (major BENS). External validation showed a significant association between BENS score and QoL (P = 0.0001). The BENS scoring system is limited by the fact that it was developed from a single endometriosis unit in Denmark, making it susceptible to social, cultural and demographic bias. It is the first endometriosis classification system to be based directly on the symptomatology of the patient. Validation in other languages will promote comparison of treatments and results across borders. No external funding was either

  8. Donor impurity states and related optical response in a lateral coupled dot-ring system under applied electric field

    Energy Technology Data Exchange (ETDEWEB)

    Correa, J.D. [Departamento de Ciencias Básicas, Universidad de Medellín, Medellín (Colombia); Mora-Ramos, M.E. [Centro de Investigación en Ciencias, Instituto de Ciencias Básicas y Aplicadas, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001, CP 62209 Cuernavaca, Morelos (Mexico); Duque, C.A., E-mail: cduque@fisica.udea.edu.co [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia)

    2015-09-01

    A study on the effects of an externally applied electric field on the linear optical absorption and relative refractive index change associated with transitions between off-center donor impurity states in laterally coupled quantum dot-ring system is reported. Electron states are calculated within the effective mass and parabolic band approximations by means of an exact diagonalization procedure. The states and the optical response in each case show significant sensitivity to the geometrical distribution of confining energies as well as to the strength of the applied field.

  9. Donor impurity states and related optical response in a lateral coupled dot-ring system under applied electric field

    International Nuclear Information System (INIS)

    Correa, J.D.; Mora-Ramos, M.E.; Duque, C.A.

    2015-01-01

    A study on the effects of an externally applied electric field on the linear optical absorption and relative refractive index change associated with transitions between off-center donor impurity states in laterally coupled quantum dot-ring system is reported. Electron states are calculated within the effective mass and parabolic band approximations by means of an exact diagonalization procedure. The states and the optical response in each case show significant sensitivity to the geometrical distribution of confining energies as well as to the strength of the applied field

  10. Development of Organ-Specific Donor Risk Indices

    Science.gov (United States)

    Akkina, Sanjeev K.; Asrani, Sumeet K.; Peng, Yi; Stock, Peter; Kim, Ray; Israni, Ajay K.

    2012-01-01

    Due to the shortage of deceased donor organs, transplant centers accept organs from marginal deceased donors, including older donors. Organ-specific donor risk indices have been developed to predict graft survival using various combinations of donor and recipient characteristics. We will review the kidney donor risk index (KDRI) and liver donor risk index (LDRI) and compare and contrast their strengths, limitations, and potential uses. The Kidney Donor Risk Index has a potential role in developing new kidney allocation algorithms. The Liver Donor Risk Index allows for greater appreciation of the importance of donor factors, particularly for hepatitis C-positive recipients; as the donor risk index increases, rates of allograft and patient survival among these recipients decrease disproportionately. Use of livers with high donor risk index is associated with increased hospital costs independent of recipient risk factors, and transplanting livers with high donor risk index into patients with Model for End-Stage Liver Disease scores Donor Risk Index has limited this practice. Significant regional variation in donor quality, as measured by the Liver Donor Risk Index, remains in the United States. We also review other potential indices for liver transplant, including donor-recipient matching and the retransplant donor risk index. While substantial progress has been made in developing donor risk indices to objectively assess donor variables that affect transplant outcomes, continued efforts are warranted to improve these indices to enhance organ allocation policies and optimize allograft survival. PMID:22287036

  11. Neonatal facial coding system scores and spectral characteristics of infant crying during newborn circumcision.

    Science.gov (United States)

    Lehr, Victoria Tutag; Zeskind, Philip Sanford; Ofenstein, John P; Cepeda, Eugene; Warrier, Indulekha; Aranda, J V

    2007-06-01

    To determine the relations between Neonatal Facial Coding System (NFCS) scores and measures of infant crying during newborn circumcision. Video and audio recordings were made of infant facial activity and cry sounds, respectively, during the lysis phase of circumcisions of 44 healthy term males (analgesia before circumcision. NFCS scores were determined by blinded assistant from video recordings of facial activity. Measures of infant crying were determined via spectrum analysis of audio recordings by a blinded, independent researcher. Pearson product-moment correlations were used to examine relationship between NFCS scores and measures of crying. Principal component factor analysis detected dimensions underlying related measures of crying. Factor scores from a factor analysis were used in stepwise linear regression to predict NFCS scores. Higher NFCS scores correlated with lower peak fundamental frequency of crying (P<0.01) and with higher amplitudes of crying at peak fundamental frequency and dominant frequency and in overall cry sample (P<0.01). The factor analysis showed 3 significant orthogonal dimensions underlying measures of crying: Power and Velocity (amplitude and rapidity), Pitch of Crying (frequency characteristics), and Infant Arousal (turbulence and intensity) accounting for 42.3%, 17.8%, and 14.6% of variance, respectively. A regression analysis showed all 3 factor scores accounted for significant and separate portions of variance (P<0.001). The best predictor of NFCS score was Power and Velocity (P<0.002), followed by Infant Arousal (P<0.002), and Pitch of Crying (P<0.007). These data provide some of the first known evidence linking specific measures of infant crying with an independent, validated measure of pain.

  12. Liver stiffness measurement-based scoring system for significant inflammation related to chronic hepatitis B.

    Directory of Open Access Journals (Sweden)

    Mei-Zhu Hong

    Full Text Available Liver biopsy is indispensable because liver stiffness measurement alone cannot provide information on intrahepatic inflammation. However, the presence of fibrosis highly correlates with inflammation. We constructed a noninvasive model to determine significant inflammation in chronic hepatitis B patients by using liver stiffness measurement and serum markers.The training set included chronic hepatitis B patients (n = 327, and the validation set included 106 patients; liver biopsies were performed, liver histology was scored, and serum markers were investigated. All patients underwent liver stiffness measurement.An inflammation activity scoring system for significant inflammation was constructed. In the training set, the area under the curve, sensitivity, and specificity of the fibrosis-based activity score were 0.964, 91.9%, and 90.8% in the HBeAg(+ patients and 0.978, 85.0%, and 94.0% in the HBeAg(- patients, respectively. In the validation set, the area under the curve, sensitivity, and specificity of the fibrosis-based activity score were 0.971, 90.5%, and 92.5% in the HBeAg(+ patients and 0.977, 95.2%, and 95.8% in the HBeAg(- patients. The liver stiffness measurement-based activity score was comparable to that of the fibrosis-based activity score in both HBeAg(+ and HBeAg(- patients for recognizing significant inflammation (G ≥3.Significant inflammation can be accurately predicted by this novel method. The liver stiffness measurement-based scoring system can be used without the aid of computers and provides a noninvasive alternative for the prediction of chronic hepatitis B-related significant inflammation.

  13. Forecast skill score assessment of a relocatable ocean prediction system, using a simplified objective analysis method

    Science.gov (United States)

    Onken, Reiner

    2017-11-01

    A relocatable ocean prediction system (ROPS) was employed to an observational data set which was collected in June 2014 in the waters to the west of Sardinia (western Mediterranean) in the framework of the REP14-MED experiment. The observational data, comprising more than 6000 temperature and salinity profiles from a fleet of underwater gliders and shipborne probes, were assimilated in the Regional Ocean Modeling System (ROMS), which is the heart of ROPS, and verified against independent observations from ScanFish tows by means of the forecast skill score as defined by Murphy(1993). A simplified objective analysis (OA) method was utilised for assimilation, taking account of only those profiles which were located within a predetermined time window W. As a result of a sensitivity study, the highest skill score was obtained for a correlation length scale C = 12.5 km, W = 24 h, and r = 1, where r is the ratio between the error of the observations and the background error, both for temperature and salinity. Additional ROPS runs showed that (i) the skill score of assimilation runs was mostly higher than the score of a control run without assimilation, (i) the skill score increased with increasing forecast range, and (iii) the skill score for temperature was higher than the score for salinity in the majority of cases. Further on, it is demonstrated that the vast number of observations can be managed by the applied OA method without data reduction, enabling timely operational forecasts even on a commercially available personal computer or a laptop.

  14. Reliability of a visual scoring system with fluorescent tracers to assess dermal pesticide exposure.

    Science.gov (United States)

    Aragon, Aurora; Blanco, Luis; Lopez, Lylliam; Liden, Carola; Nise, Gun; Wesseling, Catharina

    2004-10-01

    We modified Fenske's semi-quantitative 'visual scoring system' of fluorescent tracer deposited on the skin of pesticide applicators and evaluated its reproducibility in the Nicaraguan setting. The body surface of 33 farmers, divided into 31 segments, was videotaped in the field after spraying with a pesticide solution containing a fluorescent tracer. A portable UV lamp was used for illumination in a foldaway dark room. The videos of five farmers were randomly selected. The scoring was based on a matrix with extension of fluorescent patterns (scale 0-5) on the ordinate and intensity (scale 0-5) on the abscissa, with the product of these two ranks as the final score for each body segment (0-25). Five medical students rated and evaluated the quality of 155 video images having undergone 4 h of training. Cronbach alpha coefficients and two-way random effects intraclass correlation coefficients (ICC) with absolute agreement were computed to assess inter-rater reliability. Consistency was high (Cronbach alpha = 0.96), but the scores differed substantially between raters. The overall ICC was satisfactory [0.75; 95% confidence interval (CI) = 0.62-0.83], but it was lower for intensity (0.54; 95% CI = 0.40-0.66) and higher for extension (0.80; 95% CI = 0.71-0.86). ICCs were lowest for images with low scores and evaluated as low quality, and highest for images with high scores and high quality. Inter-rater reliability coefficients indicate repeatability of the scoring system. However, field conditions for recording fluorescence should be improved to achieve higher quality images, and training should emphasize a better mechanism for the reading of body areas with low contamination.

  15. External validation of scoring systems in risk stratification of upper gastrointestinal bleeding.

    Science.gov (United States)

    Anchu, Anna Cherian; Mohsina, Subair; Sureshkumar, Sathasivam; Mahalakshmy, T; Kate, Vikram

    2017-03-01

    The aim of this study was to externally validate the four commonly used scoring systems in the risk stratification of patients with upper gastrointestinal bleed (UGIB). Patients of UGIB who underwent endoscopy within 24 h of presentation were stratified prospectively using the pre-endoscopy Rockall score (PRS) >0, complete Rockall score (CRS) >2, Glasgow Blatchford bleeding scores (GBS) >3, and modified GBS (m-GBS) >3 scores. Patients were followed up to 30 days. Prognostic accuracy of the scores was done by comparing areas under curve (AUC) in terms of overall risk stratification, re-bleeding, mortality, need for intervention, and length of hospitalization. One hundred and seventy-five patients were studied. All four scores performed better in the overall risk stratification on AUC [PRS = 0.566 (CI: 0.481-0.651; p-0.043)/CRS = 0.712 (CI: 0.634-0.790); p0.001); m-GBS = 0.802 (CI: 0.734-0.871; pbleed [AUC-0.679 (CI: 0.579-0.780; p = 0.003)]. All the scoring systems except PRS were found to be significantly better in detecting 30-day mortality with a high AUC (CRS = 0.798; p-0.042)/GBS = 0.833; p-0.023); m-GBS = 0.816; p-0.031). All four scores demonstrated significant accuracy in the risk stratification of non-variceal patients; however, only GBS and m-GBS were significant in variceal etiology. Higher cutoff scores achieved better sensitivity/specificity [RS > 0 (50/60.8), CRS > 1 (87.5/50.6), GBS > 7 (88.5/63.3), m-GBS > 7(82.3/72.6)] in the risk stratification. GBS and m-GBS appear to be more valid in risk stratification of UGIB patients in this region. Higher cutoff values achieved better predictive accuracy.

  16. Modified PADSS (Post Anaesthetic Discharge Scoring System) for monitoring outpatients discharge.

    Science.gov (United States)

    Palumbo, Piergaspare; Tellan, Guglielmo; Perotti, Bruno; Pacilè, Maria Antonietta; Vietri, Francesco; Illuminati, Giulio

    2013-01-01

    The decision to discharge a patient undergoing day surgery is a major step in the hospitalization pathway, because it must be achieved without compromising the quality of care, thus ensuring the same assistance and wellbeing as for a long-term stay. Therefore, the use of an objective assessment for the management of a fair and safe discharge is essential. The authors propose the Post Anaesthetic Discharge Scoring System (PADSS), which considers six criteria: vital signs, ambulation, nausea/vomiting, pain, bleeding and voiding. Each criterion is given a score ranging from 0 to 2. Only patients who achieve a score of 9 or more are considered ready for discharge. Furthermore, PADSS has been modified to ensure a higher level of safety, thus the "vital signs" criteria must never score lower than 2, and none of the other five criteria must ever be equal to 0, even if the total score reaches 9. The effectiveness of PADSS was analyzed on 2432 patients, by recording the incidence of postoperative complications and the readmission to hospital. So far PADDS has proved to be an efficient system that guarantees safe discharge.

  17. Proposal of a CT scoring system of the paranasal sinuses in diagnosing cystic fibrosis

    International Nuclear Information System (INIS)

    Eggesboe, H.B.; Soevik, S.; Doelvik, S.; Eiklid, K.; Kolmannskog, F.

    2003-01-01

    The purpose of this study was to develop a paranasal sinus CT scoring system that could be used as a diagnostic tool to discriminate cystic fibrosis (CF) patients from control patients examined for sinonasal disease. The model should include as few and easily applicable criteria as possible, supported by statistical analyses and clinical judgement. We used data from 116 CF and 136 control patients. The CF patients were grouped according to the number of confirmed CF mutations: genetically verified (CF-2), or based on sweat testing and clinical findings alone (CF-1, CF-0). Nine paranasal sinus CT criteria, including development, pneumatisation variants and inflammatory patterns, were evaluated. The final model included three criteria: (a) frontal and (b) sphenoid sinus development, and (c) absence of three pneumatisation variants. This model discriminated CF-2 from controls with overlap of summed scores in only 8 of 206 patients. When this model was applied in the CF-1 and CF-0 groups, two populations seemed to exist. A larger group with summed scores overlapping that of the CF-2 group and a smaller group with summed scores overlapping that of the control group. We conclude that this CT scoring system may support, as well as exclude, a CF diagnosis in cases of diagnostic uncertainty. (orig.)

  18. Comparison of Glasgow-Blatchford score and full Rockall score systems to predict clinical outcomes in patients with upper gastrointestinal bleeding

    Directory of Open Access Journals (Sweden)

    Mokhtare M

    2016-10-01

    Full Text Available Marjan Mokhtare, Vida Bozorgi, Shahram Agah, Mehdi Nikkhah, Amirhossein Faghihi, Amirhossein Boghratian, Neda Shalbaf, Abbas Khanlari, Hamidreza Seifmanesh Colorectal Research Center, Rasoul Akram Hospital, Tehran, Iran Background: Various risk scoring systems have been recently developed to predict clinical outcomes in patients with upper gastrointestinal bleeding (UGIB. The two commonly used scoring systems include full Rockall score (RS and the Glasgow-Blatchford score (GBS. Bleeding scores were assessed in terms of prediction of clinical outcomes in patients with UGIB. Patients and methods: Two hundred patients (age >18 years with obvious symptoms of UGIB in the emergency department of Rasoul Akram Hospital were enrolled. Full RS and GBS were calculated. We followed the patients for records of rebleeding and 1-month mortality. A receiver operating characteristic curve by using areas under the curve (AUCs was used to statistically identify the best cutoff point. Results: Eighteen patients were excluded from the study due to failure to follow-up. Rebleeding and mortality rate were 9.34% (n=17 and 11.53% (n=21, respectively. Regarding 1-month mortality, full RS was better than GBS (AUC, 0.648 versus 0.582; P=0.021. GBS was more accurate in terms of detecting transfusion need (AUC, 0.757 versus 0.528; P=0.001, rebleeding rate (AUC, 0.722 versus 0.520; P=0.002, intensive care unit admission rate (AUC, 0.648 versus 0.582; P=0.021, and endoscopic intervention rate (AUC, 0.771 versus 0.650; P<0.001. Conclusion: We found the full RS system is better for 1-month mortality prediction while GBS system is better for prediction of other outcomes. Keywords: full Rockall score, Glasgow-Blatchford score, gastrointestinal bleeding, mortality, prognosis

  19. Ultrasonography-guided percutaneous radiofrequency ablation of hepatocellular carcinomas: A feasibility scoring system for planning sonography

    International Nuclear Information System (INIS)

    Rhim, Hyunchul; Choi, Dongil; Kim, Young-sun; Lim, Hyo K.; Choe, Bong-Keun

    2010-01-01

    Purpose: This study was designed to evaluate whether a feasibility scoring system for planning sonography is a reliable predictor of a safe and complete ablation in ultrasonography (US)-guided percutaneous radiofrequency ablation (RFA) of hepatocellular carcinomas (HCCs). Materials and methods: We retrospectively evaluated the therapeutic outcomes of 108 consecutive patients (M:F, 78:30; mean age, 57.4 years) with a single nodular HCC (mean diameter, 2.0 cm) treated by percutaneous RFA. All patients were assessed for the feasibility of performing an RFA at planning sonography prior to the ablation. The feasibility scoring system consisted of five categories: the safe electrode path (P); the vital organs adjacent to the RFA zone (O); tumor size (S); tumor conspicuity (C); and the heat-sink effect (H). Each category was divided into a four-point scale [1-4]. If a score of 4 in any category was determined, the patient was not considered to be a suitable candidate for percutaneous RFA. We assessed if the score of each category, safety score (P + O), and curability score (S + C + H) correlated with a safe and complete ablation using the chi-squared test and likelihood ratio test for trend. Results: The technical success rate was 100% (108/108) based on CT images obtained immediately after ablation. There was no 30-day mortality after RFA. There were major complications (one case of severe vasovagal reflex, one case of hemoperitoneum and one case of a pseudoaneurysm) in three (2.7%) patients, and minor complications (one case of a biloma, one case of subsegmental infarction and one case of abscess) in three (2.7%) patients. Post-ablation syndrome as a side effect was noted in 38 (35.1%) of 108 patients. The primary technique effectiveness rate at 1 month was 95.1% (105/108). Local tumor progression was noted in eight (7.6%) of 105 patients during the follow-up period (range, 3.0-11.5 months; median, 5.8 months; mean, 5.7 months). There was no significant single category

  20. Sample size calculation to externally validate scoring systems based on logistic regression models.

    Directory of Open Access Journals (Sweden)

    Antonio Palazón-Bru

    Full Text Available A sample size containing at least 100 events and 100 non-events has been suggested to validate a predictive model, regardless of the model being validated and that certain factors can influence calibration of the predictive model (discrimination, parameterization and incidence. Scoring systems based on binary logistic regression models are a specific type of predictive model.The aim of this study was to develop an algorithm to determine the sample size for validating a scoring system based on a binary logistic regression model and to apply it to a case study.The algorithm was based on bootstrap samples in which the area under the ROC curve, the observed event probabilities through smooth curves, and a measure to determine the lack of calibration (estimated calibration index were calculated. To illustrate its use for interested researchers, the algorithm was applied to a scoring system, based on a binary logistic regression model, to determine mortality in intensive care units.In the case study provided, the algorithm obtained a sample size with 69 events, which is lower than the value suggested in the literature.An algorithm is provided for finding the appropriate sample size to validate scoring systems based on binary logistic regression models. This could be applied to determine the sample size in other similar cases.

  1. New scoring system for intra-abdominal injury diagnosis after blunt trauma.

    Science.gov (United States)

    Shojaee, Majid; Faridaalaee, Gholamreza; Yousefifard, Mahmoud; Yaseri, Mehdi; Arhami Dolatabadi, Ali; Sabzghabaei, Anita; Malekirastekenari, Ali

    2014-01-01

    An accurate scoring system for intra-abdominal injury (IAI) based on clinical manifestation and examination may decrease unnecessary CT scans, save time, and reduce healthcare cost. This study is designed to provide a new scoring system for a better diagnosis of IAI after blunt trauma. This prospective observational study was performed from April 2011 to October 2012 on patients aged above 18 years and suspected with blunt abdominal trauma (BAT) admitted to the emergency department (ED) of Imam Hussein Hospital and Shohadaye Hafte Tir Hospital. All patients were assessed and treated based on Advanced Trauma Life Support and ED protocol. Diagnosis was done according to CT scan findings, which was considered as the gold standard. Data were gathered based on patient's history, physical exam, ultrasound and CT scan findings by a general practitioner who was not blind to this study. Chi-square test and logistic regression were done. Factors with significant relationship with CT scan were imported in multivariate regression models, where a coefficient (β) was given based on the contribution of each of them. Scoring system was developed based on the obtained total β of each factor. Altogether 261 patients (80.1% male) were enrolled (48 cases of IAI). A 24-point blunt abdominal trauma scoring system (BATSS) was developed. Patients were divided into three groups including low (scoretool for BAT detection and has the potential to reduce unnecessary CT scan and cut unnecessary costs.

  2. A Score Function for Optimizing the Cycle-Life of Battery-Powered Embedded Systems

    NARCIS (Netherlands)

    Wognsen, Erik Ramsgaard; Haverkort, Boudewijn R.H.M.; Jongerden, M.R.; Hansen, René Rydhof; Larsen, K.G.; Sankaranarayanan, Sriram; Vicario, Enrico

    An ever increasing share of embedded systems is powered by rechargeable batteries. These batteries deteriorate with the number of charge/discharge cycles they are subjected to, the so-called cycle life. In this paper, we propose the wear score function to compare and evaluate the relative impact of

  3. Manual and automatic locomotion scoring systems in dairy cows: A review

    NARCIS (Netherlands)

    Schlageter-Tello, A.; Bokkers, E.A.M.; Groot Koerkamp, P.W.G.; Hertem, van T.; Viazzi, S.; Romanini Bites, E.; Halachmi, I.; Bahr, C.; Berckmans, D.; Lokhorst, K.

    2014-01-01

    The objective of this review was to describe, compare and evaluate agreement, reliability, and validity of manual and automatic locomotion scoring systems (MLSSs and ALSSs, respectively) used in dairy cattle lameness research. There are many different types of MLSSs and ALSSs. Twenty-five MLSSs were

  4. Prospective validation of the International Society of Thrombosis and Haemostasis scoring system for disseminated intravascular coagulation

    NARCIS (Netherlands)

    Bakhtiari, Kamran; Meijers, Joost C. M.; de Jonge, Evert; Levi, Marcel

    2004-01-01

    Objectives: A diagnosis of disseminated intravascular coagulation (DIC) is hampered by the lack of an accurate diagnostic test. Based on the retrospective analysis of studies in patients with DIC, a scoring system (0-8 points) using simple and readily available routine laboratory tests has been

  5. Portsmouth physiological and operative severity score for the Enumeration of Mortality and morbidity scoring system in general surgical practice and identifying risk factors for poor outcome

    Science.gov (United States)

    Tyagi, Ashish; Nagpal, Nitin; Sidhu, D. S.; Singh, Amandeep; Tyagi, Anjali

    2017-01-01

    Background: Estimation of the outcome is paramount in disease stratification and subsequent management in severely ill surgical patients. Risk scoring helps us quantify the prospects of adverse outcome in a patient. Portsmouth-Physiological and Operative Severity Score for the Enumeration of Mortality and Morbidity (P-POSSUM) the world over has proved itself as a worthy scoring system and the present study was done to evaluate the feasibility of P-POSSUM as a risk scoring system as a tool in efficacious prediction of mortality and morbidity in our demographic profile. Materials and Methods: Validity of P-POSSUM was assessed prospectively in fifty major general surgeries performed at our hospital from May 2011 to October 2012. Data were collected to obtain P-POSSUM score, and statistical analysis was performed. Results: Majority (72%) of patients was male and mean age was 40.24 ± 18.6 years. Seventy-eight percentage procedures were emergency laparotomies commonly performed for perforation peritonitis. Mean physiological score was 17.56 ± 7.6, and operative score was 17.76 ± 4.5 (total score = 35.3 ± 10.4). The ratio of observed to expected mortality rate was 0.86 and morbidity rate was 0.78. Discussion: P-POSSUM accurately predicted both mortality and morbidity in patients who underwent major surgical procedures in our setup. Thus, it helped us in identifying patients who required preferential attention and aggressive management. Widespread application of this tool can result in better distribution of care among high-risk surgical patients. PMID:28250670

  6. Identification and Evaluation of Medical Translator Mobile Applications Using an Adapted APPLICATIONS Scoring System.

    Science.gov (United States)

    Khander, Amrin; Farag, Sara; Chen, Katherine T

    2017-12-22

    With an increasing number of patients requiring translator services, many providers are turning to mobile applications (apps) for assistance. However, there have been no published reviews of medical translator apps. To identify and evaluate medical translator mobile apps using an adapted APPLICATIONS scoring system. A list of apps was identified from the Apple iTunes and Google Play stores, using the search term, "medical translator." Apps not found on two different searches, not in an English-based platform, not used for translation, or not functional after purchase, were excluded. The remaining apps were evaluated using an adapted APPLICATIONS scoring system, which included both objective and subjective criteria. App comprehensiveness was a weighted score defined by the number of non-English languages included in each app relative to the proportion of non-English speakers in the United States. The Apple iTunes and Google Play stores. Medical translator apps identified using the search term "medical translator." Main Outcomes and Measures: Compilation of medical translator apps for provider usage. A total of 524 apps were initially found. After applying the exclusion criteria, 20 (8.2%) apps from the Google Play store and 26 (9.2%) apps from the Apple iTunes store remained for evaluation. The highest scoring apps, Canopy Medical Translator, Universal Doctor Speaker, and Vocre Translate, scored 13.5 out of 18.7 possible points. A large proportion of apps initially found did not function as medical translator apps. Using the APPLICATIONS scoring system, we have identified and evaluated medical translator apps for providers who care for non-English speaking patients.

  7. Myocardial perfusion imaging and coronary calcium scoring with a two-slice SPECT/CT system: can the attenuation map be calculated from the calcium scoring CT scan?

    Energy Technology Data Exchange (ETDEWEB)

    Wenning, Christian; Rahbar, Kambiz; Schober, Otmar; Stegger, Lars [University of Muenster, Department of Nuclear Medicine, Muenster (Germany); Vrachimis, Alexis; Schaefers, Michael [University of Muenster, Department of Nuclear Medicine, Muenster (Germany); University of Muenster, European Institute for Molecular Imaging, Muenster (Germany)

    2013-07-15

    Coronary artery calcium scoring can complement myocardial perfusion imaging (MPI). The purpose of this study was to evaluate the feasibility and accuracy of using the CalciumScore-CT derived from a combined SPECT/CT device also for SPECT attenuation correction (AC). The study group comprised 99 patients who underwent both post-stress and rest MPI using a two-slice SPECT/CT system. For AC, one of the two scans was accompanied by a CalciumScore-CT scan (CalciumScore-CTAC) and the other by a conventional spiral CT (AttenCorr-CT) scan (AttenCorr-CTAC). In 48 patients the CalciumScore-CT scan was acquired with the post-stress scan and the AttenCorr-CT scan with the rest scan, and in 51 patients the order was reversed. The accuracy of the images based on AC was determined qualitatively by consensus reading with respect to the clinical diagnoses as well as quantitatively by comparing the perfusion summed stress scores (SSS) and the summed rest scores (SRS) between attenuation-corrected and uncorrected images. In comparison to the uncorrected images CalciumScore-CTAC led to regional inaccuracies in 14 of 51 of studies (27.5 %) versus 12 of 48 studies (25 %) with AttenCorr-CTAC for the stress studies and in 5 of 48 (10 %) versus 1 of 51 (2 %) for the rest studies, respectively. This led to intermediate and definite changes in the final diagnosis (ischaemia and/or scarring) in 12 % of the studies (12 of 99) and in 7 % of the studies (7 of 99) with CalciumScore-CTAC and in 9 % of the studies (9 of 99) and 4 % of the studies (4 of 99) with AttenCorr-CTAC. Differences in SSS and SRS with respect to the uncorrected images were greater for the CalciumScore-CTAC images than for the AttenCorr-CTAC images ({Delta}SSS 4.5 {+-} 5.6 and 2.1 {+-} 4.4, p = 0.023; {Delta}SRS 4.2 {+-} 4.9 and 1.6 {+-} 3.2, p = 0.004, respectively). Using the same CT scan for calcium scoring and SPECT AC is feasible. Image interpretation must, however, include uncorrected images since CT-based AC relatively

  8. Application of balanced score card in the development of performance indicator system in nuclear power plant

    International Nuclear Information System (INIS)

    Shen Shuguang; Huang Fang; Fang Zhaoxia

    2013-01-01

    Performance indicator, which is one of ten performance monitoring tools recommended by WANO performance improvement model, has become an effective tool for performance improvement of nuclear power plant. At present, performance indicator system has been built in nuclear power plant. However, how to establish the performance indicator system that is reasonable and applicable for plant is still a question to be discussed. Performance indictor is closely tied to the strategic direction of a corporation by a balanced score card, and the performance indicator system is established from the point of performance management and strategic development. The performance indicator system of nuclear power plant is developed by introducing the balanced score card, and can be as a reference for other domestic nuclear power plants. (authors)

  9. Establishment of a general NAFLD scoring system for rodent models and comparison to human liver pathology.

    Directory of Open Access Journals (Sweden)

    Wen Liang

    Full Text Available The recently developed histological scoring system for non-alcoholic fatty liver disease (NAFLD by the NASH Clinical Research Network (NASH-CRN has been widely used in clinical settings, but is increasingly employed in preclinical research as well. However, it has not been systematically analyzed whether the human scoring system can directly be converted to preclinical rodent models. To analyze this, we systematically compared human NAFLD liver pathology, using human liver biopsies, with liver pathology of several NAFLD mouse models. Based upon the features pertaining to mouse NAFLD, we aimed at establishing a modified generic scoring system that is applicable to broad spectrum of rodent models.The histopathology of NAFLD was analyzed in several different mouse models of NAFLD to define generic criteria for histological assessment (preclinical scoring system. For validation of this scoring system, 36 slides of mouse livers, covering the whole spectrum of NAFLD, were blindly analyzed by ten observers. Additionally, the livers were blindly scored by one observer during two separate assessments longer than 3 months apart.The criteria macrovesicular steatosis, microvesicular steatosis, hepatocellular hypertrophy, inflammation and fibrosis were generally applicable to rodent NAFLD. The inter-observer reproducibility (evaluated using the Intraclass Correlation Coefficient between the ten observers was high for the analysis of macrovesicular steatosis and microvesicular steatosis (ICC = 0.784 and 0.776, all p<0.001, respectively and moderate for the analysis of hypertrophy and inflammation (ICC = 0.685 and 0.650, all p<0.001, respectively. The intra-observer reproducibility between the different observations of one observer was high for the analysis of macrovesicular steatosis, microvesicular steatosis and hypertrophy (ICC = 0.871, 0.871 and 0.896, all p<0.001, respectively and very high for the analysis of inflammation (ICC = 0.931, p

  10. A Contemporary Prostate Cancer Grading System: A Validated Alternative to the Gleason Score

    Science.gov (United States)

    Epstein, Jonathan I.; Zelefsky, Michael J.; Sjoberg, Daniel D.; Nelson, Joel B.; Egevad, Lars; Magi-Galluzzi, Cristina; Vickers, Andrew J.; Parwani, Anil V.; Reuter, Victor E.; Fine, Samson W.; Eastham, James A.; Wiklund, Peter; Han, Misop; Reddy, Chandana A.; Ciezki, Jay P.; Nyberg, Tommy; Klein, Eric A.

    2016-01-01

    Background Despite revisions in 2005 and 2014, the Gleason prostate cancer (PCa) grading system still has major deficiencies. Combining of Gleason scores into a three-tiered grouping (6, 7, 8–10) is used most frequently for prognostic and therapeutic purposes. The lowest score, assigned 6, may be misunderstood as a cancer in the middle of the grading scale, and 3 + 4 = 7 and 4 + 3 = 7 are often considered the same prognostic group. Objective To verify that a new grading system accurately produces a smaller number of grades with the most significant prognostic differences, using multi-institutional and multimodal therapy data. Design, setting, and participants Between 2005 and 2014, 20 845 consecutive men were treated by radical prostatectomy at five academic institutions; 5501 men were treated with radiotherapy at two academic institutions. Outcome measurements and statistical analysis Outcome was based on biochemical recurrence (BCR). The log-rank test assessed univariable differences in BCR by Gleason score. Separate univariable and multivariable Cox proportional hazards used four possible categorizations of Gleason scores. Results and limitations In the surgery cohort, we found large differences in recurrence rates between both Gleason 3 + 4 versus 4 + 3 and Gleason 8 versus 9. The hazard ratios relative to Gleason score 6 were 1.9, 5.1, 8.0, and 11.7 for Gleason scores 3 + 4, 4 + 3, 8, and 9–10, respectively. These differences were attenuated in the radiotherapy cohort as a whole due to increased adjuvant or neoadjuvant hormones for patients with high-grade disease but were clearly seen in patients undergoing radiotherapy only. A five–grade group system had the highest prognostic discrimination for all cohorts on both univariable and multivariable analysis. The major limitation was the unavoidable use of prostate-specific antigen BCR as an end point as opposed to cancer-related death. Conclusions The new PCa grading system has these benefits: more

  11. Resonant tunneling spectroscopy of valley eigenstates on a donor-quantum dot coupled system

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, T., E-mail: t.kobayashi@unsw.edu.au; Heijden, J. van der; House, M. G.; Hile, S. J.; Asshoff, P.; Simmons, M. Y.; Rogge, S. [Centre for Quantum Computation and Communication Technology, University of New South Wales, Sydney 2052 New South Wales (Australia); Gonzalez-Zalba, M. F. [Hitachi Cambridge Laboratory, J. J. Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Vinet, M. [Université Grenoble-Alpes and CEA, LETI, MINATEC, 38000 Grenoble (France)

    2016-04-11

    We report on electronic transport measurements through a silicon double quantum dot consisting of a donor and a quantum dot. Transport spectra show resonant tunneling peaks involving different valley states, which illustrate the valley splitting in a quantum dot on a Si/SiO{sub 2} interface. The detailed gate bias dependence of double dot transport allows a first direct observation of the valley splitting in the quantum dot, which is controllable between 160 and 240 μeV with an electric field dependence 1.2 ± 0.2 meV/(MV/m). A large valley splitting is an essential requirement for implementing a physical electron spin qubit in a silicon quantum dot.

  12. Validity and reliability of a novel immunosuppressive adverse effects scoring system in renal transplant recipients.

    Science.gov (United States)

    Meaney, Calvin J; Arabi, Ziad; Venuto, Rocco C; Consiglio, Joseph D; Wilding, Gregory E; Tornatore, Kathleen M

    2014-06-12

    After renal transplantation, many patients experience adverse effects from maintenance immunosuppressive drugs. When these adverse effects occur, patient adherence with immunosuppression may be reduced and impact allograft survival. If these adverse effects could be prospectively monitored in an objective manner and possibly prevented, adherence to immunosuppressive regimens could be optimized and allograft survival improved. Prospective, standardized clinical approaches to assess immunosuppressive adverse effects by health care providers are limited. Therefore, we developed and evaluated the application, reliability and validity of a novel adverse effects scoring system in renal transplant recipients receiving calcineurin inhibitor (cyclosporine or tacrolimus) and mycophenolic acid based immunosuppressive therapy. The scoring system included 18 non-renal adverse effects organized into gastrointestinal, central nervous system and aesthetic domains developed by a multidisciplinary physician group. Nephrologists employed this standardized adverse effect evaluation in stable renal transplant patients using physical exam, review of systems, recent laboratory results, and medication adherence assessment during a clinic visit. Stable renal transplant recipients in two clinical studies were evaluated and received immunosuppressive regimens comprised of either cyclosporine or tacrolimus with mycophenolic acid. Face, content, and construct validity were assessed to document these adverse effect evaluations. Inter-rater reliability was determined using the Kappa statistic and intra-class correlation. A total of 58 renal transplant recipients were assessed using the adverse effects scoring system confirming face validity. Nephrologists (subject matter experts) rated the 18 adverse effects as: 3.1 ± 0.75 out of 4 (maximum) regarding clinical importance to verify content validity. The adverse effects scoring system distinguished 1.75-fold increased gastrointestinal adverse

  13. A review of scoring systems for ocular involvement in chronic cutaneous bullous diseases.

    Science.gov (United States)

    Lee, Brendon W H; Tan, Jeremy C K; Radjenovic, Melissa; Coroneo, Minas T; Murrell, Dedee F

    2018-05-22

    Epidermolysis bullosa (EB) and autoimmune blistering diseases (AIBD) describe a group of rare chronic dermatoses characterized by cutaneous fragility and blistering. Although uncommon, significant ocular surface disease (OSD) may occur in both and require ophthalmological assessment. Disease scoring systems have a critical role in providing objective and accurate assessment of disease severity. The objectives of this report were, firstly, to document the prevalence and severity of ocular involvement in EB/AIBD. Secondly, to review and evaluate existing ocular and systemic scoring systems for EB/AIBD. Finally, to identify areas where further development of ocular specific tools in EB/AIBD could be pursued. A literature search was performed in October 2017 utilising Medline, Embase, and Scopus databases. The results were restricted by date of publication, between 01.01.1950 and 31.10.2017. The reference lists of these articles were then reviewed for additional relevant publications. Articles of all languages were included if an English translation was available. Articles were excluded if they were duplicates, had no reference to ocular involvement in EB/AIBD or described ocular involvement in other diseases. Descriptions of ocular involvement in EB/AIBD were identified in 88 peer-reviewed journal articles. Findings reported include but are not limited to: cicatrising conjunctivitis, meibomian gland dysfunction, dry eye disease, trichiasis, symblepharon, fornix fibrosis, keratopathy, ectropion/entropion, ankyloblepharon, corneal ulceration, visual impairment and blindness. Although scoring systems exist for assessment of OSD in mucous membrane pemphigoid, no such tools exist for the other AIBD subtypes or for EB. Several systemic scoring systems exist in the dermatological literature that are efficacious in grading overall EB/AIBD severity, but have limited inclusion of ocular features. To the best of our knowledge, there is no recognised or validated scoring systems

  14. Technical feasibility and validation of a coronary artery calcium scoring system using CT coronary angiography images

    Energy Technology Data Exchange (ETDEWEB)

    Pavitt, Christopher W. [Royal Brompton Hospital, Department of Cardiology, London (United Kingdom); Royal Brompton Hospital, Department of Radiology, London (United Kingdom); Harron, Katie [Institute of Child Health, UCL, Centre for Paediatric Epidemiology and Biostatistics, London (United Kingdom); Lindsay, Alistair C.; Ray, Robin [Royal Brompton Hospital, Department of Cardiology, London (United Kingdom); Zielke, Sayeh; Rubens, Michael B. [Royal Brompton Hospital, Department of Radiology, London (United Kingdom); Gordon, Daniel [Royal Marsden Hospital, Department of Physics, London (United Kingdom); Padley, Simon P. [Royal Brompton Hospital, Department of Radiology, London (United Kingdom); Imperial College, Faculty of Medicine, London (United Kingdom); Nicol, Edward D. [Royal Brompton Hospital, Department of Cardiology, London (United Kingdom); Royal Brompton Hospital, Department of Radiology, London (United Kingdom); Imperial College, Faculty of Medicine, London (United Kingdom)

    2016-05-15

    We validate a novel CT coronary angiography (CCTA) coronary calcium scoring system. Calcium was quantified on CCTA images using a new patient-specific attenuation threshold: mean + 2SD of intra-coronary contrast density (HU). Using 335 patient data sets a conversion factor (CF) for predicting CACS from CCTA scores (CCTAS) was derived and validated in a separate cohort (n = 168). Bland-Altman analysis and weighted kappa for MESA centiles and Agatston risk groupings were calculated. Multivariable linear regression yielded a CF: CACS = (1.185 x CCTAS) + (0.002 x CCTAS x attenuation threshold). When applied to CCTA data sets there was excellent correlation (r = 0.95; p < 0.0001) and agreement (mean difference -10.4 [95 % limits of agreement -258.9 to 238.1]) with traditional calcium scores. Agreement was better for calcium scores below 500; however, MESA percentile agreement was better for high risk patients. Risk stratification was excellent (Agatston groups k = 0.88 and MESA centiles k = 0.91). Eliminating the dedicated CACS scan decreased patient radiation exposure by approximately one-third. CCTA calcium scores can accurately predict CACS using a simple, individualized, semiautomated approach reducing acquisition time and radiation exposure when evaluating patients for CAD. This method is not affected by the ROI location, imaging protocol, or tube voltage strengthening its clinical applicability. (orig.)

  15. Agreement in the assessment of metastatic spine disease using scoring systems.

    Science.gov (United States)

    Arana, Estanislao; Kovacs, Francisco M; Royuela, Ana; Asenjo, Beatriz; Pérez-Ramírez, Ursula; Zamora, Javier

    2015-04-01

    To assess variability in the use of Tomita and modified Bauer scores in spine metastases. Clinical data and imaging from 90 patients with biopsy-proven spinal metastases, were provided to 83 specialists from 44 hospitals. Spinal levels involved and the Tomita and modified Bauer scores for each case were determined twice by each clinician, with a minimum of 6-week interval. Clinicians were blinded to every evaluation. Kappa statistic was used to assess intra and inter-observer agreement. Subgroup analyses were performed according to clinicians' specialty (medical oncology, neurosurgery, radiology, orthopedic surgery and radiation oncology), years of experience (⩽7, 8-13, ⩾14), and type of hospital (four levels). For metastases identification, intra-observer agreement was "substantial" (0.600.80) at the other levels. Inter-observer agreement was "almost perfect" at lumbar spine, and "substantial" at the other levels. Intra-observer agreement for the Tomita and Bauer scores was almost perfect. Inter-observer agreement was almost perfect for the Tomita score and substantial for the Bauer one. Results were similar across specialties, years of experience and type of hospital. Agreement in the assessment of metastatic spine disease is high. These scoring systems can improve communication among clinicians involved in oncology care. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Agreement in the assessment of metastatic spine disease using scoring systems

    International Nuclear Information System (INIS)

    Arana, Estanislao; Kovacs, Francisco M.; Royuela, Ana; Asenjo, Beatriz; Pérez-Ramírez, Ursula; Zamora, Javier; Abraira, Víctor

    2015-01-01

    Purpose: To assess variability in the use of Tomita and modified Bauer scores in spine metastases. Materials and methods: Clinical data and imaging from 90 patients with biopsy-proven spinal metastases, were provided to 83 specialists from 44 hospitals. Spinal levels involved and the Tomita and modified Bauer scores for each case were determined twice by each clinician, with a minimum of 6-week interval. Clinicians were blinded to every evaluation. Kappa statistic was used to assess intra and inter-observer agreement. Subgroup analyses were performed according to clinicians’ specialty (medical oncology, neurosurgery, radiology, orthopedic surgery and radiation oncology), years of experience (⩽7, 8–13, ⩾14), and type of hospital (four levels). Results: For metastases identification, intra-observer agreement was “substantial” (0.60 < k < 0.80) at sacrum, and “almost perfect” (k > 0.80) at the other levels. Inter-observer agreement was “almost perfect” at lumbar spine, and “substantial” at the other levels. Intra-observer agreement for the Tomita and Bauer scores was almost perfect. Inter-observer agreement was almost perfect for the Tomita score and substantial for the Bauer one. Results were similar across specialties, years of experience and type of hospital. Conclusion: Agreement in the assessment of metastatic spine disease is high. These scoring systems can improve communication among clinicians involved in oncology care

  17. Weighing of risk factors for penetrating keratoplasty graft failure: application of Risk Score System

    Directory of Open Access Journals (Sweden)

    Abdo Karim Tourkmani

    2017-03-01

    Full Text Available AIM: To analyze the relationship between the score obtained in the Risk Score System (RSS proposed by Hicks et al with penetrating keratoplasty (PKP graft failure at 1y postoperatively and among each factor in the RSS with the risk of PKP graft failure using univariate and multivariate analysis. METHODS: The retrospective cohort study had 152 PKPs from 152 patients. Eighteen cases were excluded from our study due to primary failure (10 cases, incomplete medical notes (5 cases and follow-up less than 1y (3 cases. We included 134 PKPs from 134 patients stratified by preoperative risk score. Spearman coefficient was calculated for the relationship between the score obtained and risk of failure at 1y. Univariate and multivariate analysis were calculated for the impact of every single risk factor included in the RSS over graft failure at 1y. RESULTS: Spearman coefficient showed statistically significant correlation between the score in the RSS and graft failure (P0.05 between diagnosis and lens status with graft failure. The relationship between the other risk factors studied and graft failure was significant (P<0.05, although the results for previous grafts and graft failure was unreliable. None of our patients had previous blood transfusion, thus, it had no impact. CONCLUSION: After the application of multivariate analysis techniques, some risk factors do not show the expected impact over graft failure at 1y.

  18. Chromosome painting in biological dosimetry: Semi-automatic system to score stable chromosome aberrations

    International Nuclear Information System (INIS)

    Garcia-Sagredo, J.M.; Vallcorba, I.; Sanchez-Hombre, M.C.; Ferro, M.T.; San Roman Cos-Gayon, C.; Santos, A.; Malpica, N.; Ortiz, C.

    1997-01-01

    From the beginning of the description of the procedure of chromosome painting by fluorescence in situ hybridization (FISH), it was thought its possible application to score induced chromosomal aberrations in radiation exposition. With chromosome painting it is possible to detect changes between chromosomes that has been validated in radiation exposition. Translocation scoring by FISH, contrarily to the unstable dicentrics, mainly detect stable chromosome aberrations that do not disappear, it allows the capability of quantify delayed acute expositions or chronic cumulative expositions. The large number of cells that have to be analyzed for high accuracy, specially when dealing with low radiation doses, makes it almost imperative to use an automatic analysis system. After validate translocation scoring by FISH in our, we have evaluated the ability and sensitivity to detect chromosomal aberrations by chromosome using different paint probes used, showing that any combination of paint probes can be used to score induced chromosomal aberrations. Our group has developed a FISH analysis that is currently being adapted for translocation scoring analysis. It includes systematic error correction and internal control probes. The performance tests carried out show that 9,000 cells can be analyzed in 10 hr. using a Sparc 4/370. Although with a faster computer, a higher throughput is expected, for large population screening or very low radiation doses, this performance still has to be improved. (author)

  19. A Standardized DNA Variant Scoring System for Pathogenicity Assessments in Mendelian Disorders.

    Science.gov (United States)

    Karbassi, Izabela; Maston, Glenn A; Love, Angela; DiVincenzo, Christina; Braastad, Corey D; Elzinga, Christopher D; Bright, Alison R; Previte, Domenic; Zhang, Ke; Rowland, Charles M; McCarthy, Michele; Lapierre, Jennifer L; Dubois, Felicita; Medeiros, Katelyn A; Batish, Sat Dev; Jones, Jeffrey; Liaquat, Khalida; Hoffman, Carol A; Jaremko, Malgorzata; Wang, Zhenyuan; Sun, Weimin; Buller-Burckle, Arlene; Strom, Charles M; Keiles, Steven B; Higgins, Joseph J

    2016-01-01

    We developed a rules-based scoring system to classify DNA variants into five categories including pathogenic, likely pathogenic, variant of uncertain significance (VUS), likely benign, and benign. Over 16,500 pathogenicity assessments on 11,894 variants from 338 genes were analyzed for pathogenicity based on prediction tools, population frequency, co-occurrence, segregation, and functional studies collected from internal and external sources. Scores were calculated by trained scientists using a quantitative framework that assigned differential weighting to these five types of data. We performed descriptive and comparative statistics on the dataset and tested interobserver concordance among the trained scientists. Private variants defined as variants found within single families (n = 5,182), were either VUS (80.5%; n = 4,169) or likely pathogenic (19.5%; n = 1,013). The remaining variants (n = 6,712) were VUS (38.4%; n = 2,577) or likely benign/benign (34.7%; n = 2,327) or likely pathogenic/pathogenic (26.9%, n = 1,808). Exact agreement between the trained scientists on the final variant score was 98.5% [95% confidence interval (CI) (98.0, 98.9)] with an interobserver consistency of 97% [95% CI (91.5, 99.4)]. Variant scores were stable and showed increasing odds of being in agreement with new data when re-evaluated periodically. This carefully curated, standardized variant pathogenicity scoring system provides reliable pathogenicity scores for DNA variants encountered in a clinical laboratory setting. © 2015 The Authors. **Human Mutation published by Wiley Periodicals, Inc.

  20. New scoring system for intra-abdominal injury diagnosis after blunt trauma

    Directory of Open Access Journals (Sweden)

    Shojaee Majid

    2014-02-01

    Full Text Available 【Abstract】Objective: An accurate scoring system for intra-abdominal injury (IAI based on clinical manifestation and examination may decrease unnecessary CT scans, save time, and reduce healthcare cost. This study is designed to provide a new scoring system for a better diagno- sis of IAI after blunt trauma. Methods: This prospective observational study was performed from April 2011 to October 2012 on patients aged above 18 years and suspected with blunt abdominal trauma (BAT admitted to the emergency department (ED of Imam Hussein Hospital and Shohadaye Hafte Tir Hospital. All patients were assessed and treated based on Advanced Trauma Life Support and ED protocol. Diagnosis was done according to CT scan findings, which was considered as the gold standard. Data were gathered based on patient's history, physical exam, ultrasound and CT scan findings by a general practitioner who was not blind to this study. Chisquare test and logistic regression were done. Factors with significant relationship with CT scan were imported in multivariate regression models, where a coefficient (β was given based on the contribution of each of them. Scoring system was developed based on the obtained total βof each factor. Results: Altogether 261 patients (80.1% male were enrolled (48 cases of IAI. A 24-point blunt abdominal trauma scoring system (BATSS was developed. Patients were divided into three groups including low (score<8, moderate (8≤score<12 and high risk (score≥12. In high risk group immediate laparotomy should be done, moderate group needs further assessments, and low risk group should be kept under observation. Low risk patients did not show positive CT-scans (specificity 100%. Conversely, all high risk patients had positive CT-scan findings (sensitivity 100%. The receiver operating characteristic curve indicated a close relationship between the results of CT scan and BATSS (sensitivity=99.3%. Conclusion: The present scoring system furnishes a

  1. The role of the Pirani scoring system in the management of club foot by the Ponseti method.

    Science.gov (United States)

    Dyer, P J; Davis, N

    2006-08-01

    The Pirani scoring system, together with the Ponseti method of club foot management, was assessed for its predictive value. The data on 70 idiopathic club feet successfully treated by the Ponseti method and scored by Pirani's system between February 2002 and May 2004 were analysed. There was a significant positive correlation between the initial Pirani score and number of casts required to correct the deformity. A foot scoring 4 or more is likely to require at least four casts, and one scoring less than 4 will require three or fewer. A foot with a hindfoot score of 2.5 or 3 has a 72% chance of requiring a tenotomy. The Pirani scoring system is reliable, quick, and easy to use, and provides a good forecast about the likely treatment for an individual foot but a low score does not exclude the possibility that a tenotomy may be required.

  2. Hospital triage system for adult patients using an influenza-like illness scoring system during the 2009 pandemic--Mexico.

    Directory of Open Access Journals (Sweden)

    Eduardo Rodriguez-Noriega

    2010-05-01

    Full Text Available Pandemic influenza A (H1N1 virus emerged during 2009. To help clinicians triage adults with acute respiratory illness, a scoring system for influenza-like illness (ILI was implemented at Hospital Civil de Guadalajara, Mexico.A medical history, laboratory and radiology results were collected on emergency room (ER patients with acute respiratory illness to calculate an ILI-score. Patients were evaluated for admission by their ILI-score and clinicians' assessment of risk for developing complications. Nasal and throat swabs were collected from intermediate and high-risk patients for influenza testing by RT-PCR. The disposition and ILI-score of those oseltamivir-treated versus untreated, clinical characteristics of 2009 pandemic influenza A (H1N1 patients versus test-negative patients were compared by Pearson's Chi(2, Fisher's Exact, and Wilcoxon rank-sum tests.Of 1840 ER patients, 230 were initially hospitalized (mean ILI-score = 15, and the rest were discharged, including 286 ambulatory patients given oseltamivir (median ILI-score = 11, and 1324 untreated (median ILI-score = 5. Fourteen (1% untreated patients returned, and 3 were hospitalized on oseltamivir (median ILI-score = 19. Of 371 patients tested by RT-PCR, 104 (28% had pandemic influenza and 42 (11% had seasonal influenza A detected. Twenty (91% of 22 imaged hospitalized pandemic influenza patients had bilateral infiltrates compared to 23 (38% of 61 imaged hospital test-negative patients (p<0.001. One patient with confirmed pandemic influenza presented 6 days after symptom onset, required mechanical ventilation, and died.The triaging system that used an ILI-score complimented clinicians' judgment of who needed oseltamivir and inpatient care and helped hospital staff manage a surge in demand for services.

  3. Evaluation of the Environmental Scoring System in Multiple Child Asthma Intervention Programs in Boston, Massachusetts.

    Science.gov (United States)

    Dong, Zhao; Nath, Anjali; Guo, Jing; Bhaumik, Urmi; Chin, May Y; Dong, Sherry; Marshall, Erica; Murphy, Johnna S; Sandel, Megan T; Sommer, Susan J; Ursprung, W W Sanouri; Woods, Elizabeth R; Reid, Margaret; Adamkiewicz, Gary

    2018-01-01

    To test the applicability of the Environmental Scoring System, a quick and simple approach for quantitatively measuring environmental triggers collected during home visits, and to evaluate its contribution to improving asthma outcomes among various child asthma programs. We pooled and analyzed data from multiple child asthma programs in the Greater Boston Area, Massachusetts, collected in 2011 to 2016, to examine the association of environmental scores (ES) with measures of asthma outcomes and compare the results across programs. Our analysis showed that demographics were important contributors to variability in asthma outcomes and total ES, and largely explained the differences among programs at baseline. Among all programs in general, we found that asthma outcomes were significantly improved and total ES significantly reduced over visits, with the total Asthma Control Test score negatively associated with total ES. Our study demonstrated that the Environmental Scoring System is a useful tool for measuring home asthma triggers and can be applied regardless of program and survey designs, and that demographics of the target population may influence the improvement in asthma outcomes.

  4. Impact of a new simplified disability scoring system for adult patients with localized scleroderma.

    Science.gov (United States)

    Okiyama, Naoko; Asano, Yoshihide; Hamaguchi, Yasuhito; Jinnin, Masatoshi; Motegi, Sei-Ichiro; Koizumi, Haruka; Hasegawa, Minoru; Ishikawa, Osamu; Sato, Shinichi; Takehara, Kazuhiko; Yamamoto, Toshiyuki; Fujimoto, Manabu; Ihn, Hironobu

    2018-04-01

    Localized scleroderma (LoS) involves dermal but not internal inflammation and fibrosis. Cosmetic changes often impact quality of life (QOL), however, impairment of activities of daily living (ADL) in LoS patients has not been investigated. To determine what factor(s) are associated with ADL in adult patients with LoS, we performed a retrospective observational study in 177 Japanese adult LoS patients using a novel LoS disability score based on Barthel's indices of ADL: feeding, bathing, grooming, dressing, bowels, bladder, toilet use, transfers, mobility and stairs. LoS disability scores increased in proportion to the number of affected body parts but were not correlated to age and duration of illness. The presence of leg lesions significantly impaired ADL of LoS patients compared with lesions on other body parts. Patients treated with systemic medications, who tended to have multiple lesions, presented higher LoS disability scores than those without systemic treatments. Our study proposes that physicians evaluate ADL, not only QOL, in LoS patients. Our findings using LoS disability scoring indicate that multiple affected body parts and leg lesions are risk factors for ADL impairment. © 2018 Japanese Dermatological Association.

  5. Ocular manifestation in Marfan syndrome: corneal biomechanical properties relate to increased systemic score points.

    Science.gov (United States)

    Scheibenberger, Dido; Frings, Andreas; Steinberg, Johannes; Schüler, Helke; Druchkiv, Vasyl; Katz, Toam; von Kodolitsch, Yskert; Linke, Stephan

    2018-06-01

    To evaluate corneal deformation to an air puff as a new noninvasive tool to document disease status in Marfan syndrome (MFS) METHODS: Prospective observational cohort study. We included patients diagnosed with MFS who had their routine cardiovascular follow-up and applied the revised Ghent nosology to define two subgroups according to a high (≥ 7) and a low (< 7 points) systemic score. Dynamic Scheimpflug-based biomechanical analyses (CorvisST® [CST; Oculus GmbH]) were performed. The main outcome measure was the displacement of the corneal apex as given by the parameters highest concavity (HC; in ms), peak distance (PD; in mm), and highest concavity deformation amplitude (DA; mm). Forty-three eyes of 43 individuals (19 female, 24 male; mean age 42.0 ± 12.0 years, range 18-67 years) diagnosed with MFS were included. Applying the Ghent criteria, 21 patients had an advanced systemic score of ≥ 7, and 22 had score points < 7. There were no differences in age or sex between both groups. In contrast, HC was faster (P = 0.004), and PD (P < 0.001) was longer in those individuals with systemic score ≥ 7; maximum DA did not result in a statistically significant difference between the groups (P = 0.250). In vivo noninvasive biomechanical analyses with CST offer a new, non-invasive method to identify pathologic corneal deformation responses in adults with MFS. In the future, corneal deformation to an air puff could thus assist early identification of patients with high Ghent score as an adjunct to existing diagnostic tests.

  6. Suitability of olive oil washing water as an electron donor in a feed batch operating bio-electrochemical system

    Directory of Open Access Journals (Sweden)

    F. G. Fermoso

    2017-06-01

    Full Text Available Olive oil washing water derived from the two-phase manufacturing process was assessed as an electron donor in a bio-electrochemical system (BES operating at 35 ºC. Start-up was carried out by using acetate as a substrate for the BES, reaching a potential of around +680 mV. After day 54, BES was fed with olive oil washing water. The degradation of olive oil washing water in the BES generated a maximum voltage potential of around +520 mV and a Chemical Oxygen Demand (COD removal efficiency of 41%. However, subsequent loads produced a decrease in the COD removal, while current and power density diminished greatly. The deterioration of these parameters could be a consequence of the accumulation of recalcitrant or inhibitory compounds, such as phenols. These results demonstrated that the use of olive oil washing water as an electron donor in a BES is feasible, although it has to be further investigated in order to make it more suitable for a real application.

  7. Suitability of olive oil washing water as an electron donor in a feed batch operating bio-electrochemical system

    International Nuclear Information System (INIS)

    Fermoso, F.G.; Fernández-Rodríguez, M.J.; Jiménez-Rodríguez, A.; Serrano, A.; Borja, R.

    2017-01-01

    Olive oil washing water derived from the two-phase manufacturing process was assessed as an electron donor in a bio-electrochemical system (BES) operating at 35 ºC. Start-up was carried out by using acetate as a substrate for the BES, reaching a potential of around +680 mV. After day 54, BES was fed with olive oil washing water. The degradation of olive oil washing water in the BES generated a maximum voltage potential of around +520 mV and a Chemical Oxygen Demand (COD) removal efficiency of 41%. However, subsequent loads produced a decrease in the COD removal, while current and power density diminished greatly. The deterioration of these parameters could be a consequence of the accumulation of recalcitrant or inhibitory compounds, such as phenols. These results demonstrated that the use of olive oil washing water as an electron donor in a BES is feasible, although it has to be further investigated in order to make it more suitable for a real application. [es

  8. Risk of tumor transmission after thoracic allograft transplantation from adult donors with central nervous system neoplasm-A UNOS database study.

    Science.gov (United States)

    Hynes, Conor F; Ramakrishnan, Karthik; Alfares, Fahad A; Endicott, Kendal M; Hammond-Jack, Katrina; Zurakowski, David; Jonas, Richard A; Nath, Dilip S

    2017-04-01

    We analyzed the UNOS database to better define the risk of transmission of central nervous system (CNS) tumors from donors to adult recipients of thoracic organs. Data were procured from the Standard Transplant Analysis and Research dataset files. Donors with CNS tumors were identified, and recipients from these donors comprised the study group (Group I). The remaining recipients of organs from donors who did not have CNS tumors formed the control group (Group II). Incidence of recipient CNS tumors, donor-related malignancies, and overall survival were calculated and compared in addition to multivariable logistic regression. A cohort of 58 314 adult thoracic organ recipients were included, of which 337 received organs from donors who had documented CNS tumors (Group I). None of these recipients developed CNS tumors at a median follow-up of 72 months (IR: 30-130 months). Although overall mortality in terms of the percentage was higher in Group I than Group II (163/320=51% vs 22 123/52 691=42%), Kaplan-Meier curves indicate no significant difference in the time to death between the two groups (P=.92). There is little risk of transmission of the common nonaggressive CNS tumors to recipients of thoracic organs. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Rating the methodological quality in systematic reviews of studies on measurement properties: a scoring system for the COSMIN checklist.

    Science.gov (United States)

    Terwee, Caroline B; Mokkink, Lidwine B; Knol, Dirk L; Ostelo, Raymond W J G; Bouter, Lex M; de Vet, Henrica C W

    2012-05-01

    The COSMIN checklist is a standardized tool for assessing the methodological quality of studies on measurement properties. It contains 9 boxes, each dealing with one measurement property, with 5-18 items per box about design aspects and statistical methods. Our aim was to develop a scoring system for the COSMIN checklist to calculate quality scores per measurement property when using the checklist in systematic reviews of measurement properties. The scoring system was developed based on discussions among experts and testing of the scoring system on 46 articles from a systematic review. Four response options were defined for each COSMIN item (excellent, good, fair, and poor). A quality score per measurement property is obtained by taking the lowest rating of any item in a box ("worst score counts"). Specific criteria for excellent, good, fair, and poor quality for each COSMIN item are described. In defining the criteria, the "worst score counts" algorithm was taken into consideration. This means that only fatal flaws were defined as poor quality. The scores of the 46 articles show how the scoring system can be used to provide an overview of the methodological quality of studies included in a systematic review of measurement properties. Based on experience in testing this scoring system on 46 articles, the COSMIN checklist with the proposed scoring system seems to be a useful tool for assessing the methodological quality of studies included in systematic reviews of measurement properties.

  10. Predicting hospital-acquired infections by scoring system with simple parameters.

    Directory of Open Access Journals (Sweden)

    Ying-Jui Chang

    Full Text Available BACKGROUND: Hospital-acquired infections (HAI are associated with increased attributable morbidity, mortality, prolonged hospitalization, and economic costs. A simple, reliable prediction model for HAI has great clinical relevance. The objective of this study is to develop a scoring system to predict HAI that was derived from Logistic Regression (LR and validated by Artificial Neural Networks (ANN simultaneously. METHODOLOGY/PRINCIPAL FINDINGS: A total of 476 patients from all the 806 HAI inpatients were included for the study between 2004 and 2005. A sample of 1,376 non-HAI inpatients was randomly drawn from all the admitted patients in the same period of time as the control group. External validation of 2,500 patients was abstracted from another academic teaching center. Sixteen variables were extracted from the Electronic Health Records (EHR and fed into ANN and LR models. With stepwise selection, the following seven variables were identified by LR models as statistically significant: Foley catheterization, central venous catheterization, arterial line, nasogastric tube, hemodialysis, stress ulcer prophylaxes and systemic glucocorticosteroids. Both ANN and LR models displayed excellent discrimination (area under the receiver operating characteristic curve [AUC]: 0.964 versus 0.969, p = 0.507 to identify infection in internal validation. During external validation, high AUC was obtained from both models (AUC: 0.850 versus 0.870, p = 0.447. The scoring system also performed extremely well in the internal (AUC: 0.965 and external (AUC: 0.871 validations. CONCLUSIONS: We developed a scoring system to predict HAI with simple parameters validated with ANN and LR models. Armed with this scoring system, infectious disease specialists can more efficiently identify patients at high risk for HAI during hospitalization. Further, using parameters either by observation of medical devices used or data obtained from EHR also provided good prediction

  11. Recruitment of feces donors among blood donors

    DEFF Research Database (Denmark)

    Dahl Jørgensen, Simon Mark; Erikstrup, Christian; Dinh, Khoa Manh

    2018-01-01

    As the use of fecal microbiota transplantation (FMT) has gained momentum, an increasing need for continuous access to healthy feces donors has developed. Blood donors constitute a healthy subset of the general population and may serve as an appropriate group for recruitment. In this study, we...... investigated the suitability of blood donors as feces donors. In a prospective cohort study, we recruited blood donors onsite at a public Danish blood bank. Following their consent, the blood donors underwent a stepwise screening process: First, blood donors completed an electronic pre-screening questionnaire...... to rule out predisposing risk factors. Second, eligible blood donors had blood and fecal samples examined. Of 155 blood donors asked to participate, 137 (88%) completed the electronic pre-screening questionnaire, 16 declined, and 2 were excluded. Of the 137 donors who completed the questionnaire, 79 (58...

  12. THEORETICAL SPECTRA OF THE AM CANUM VENATICORUM BINARY SYSTEM SDSS J0926+3624: EFFECTS OF IRRADIATION ONTO THE DONOR STAR

    International Nuclear Information System (INIS)

    Sengupta, Sujan; Taam, Ronald E.

    2011-01-01

    Taking into account a range of parameters determined from evolutionary models and available observational data, the detailed non-LTE spectrum for the primary star and the irradiated donor star in the AM Canum Venaticorum system SDSS J0926+3624 are constructed based on the TLUSTY stellar atmosphere code. The combined spectrum of the primary and the donor stars along with a multicolor blackbody spectrum of the accretion disk that reproduces a detailed numerical model is compared to the Sloan Digital Sky Survey optical spectrum of the system. The photometric flux of the primary star inferred from eclipse observations is compared with the synthetic spectrum. The model fit of the two independent observations provides an upper limit on the distance of the system for different effective temperatures of the primary. In addition, an upper limit on the combined flux of the disk and the donor in the infrared region wherein the contribution of the primary is negligible is also determined. It is shown that the spectrum of a sufficiently cool donor can exhibit emission lines due to irradiation from a hot primary and the emission features should be detectable in the infrared even though the contribution of the flux from the disk dominates. Thus, it is pointed out that infrared observations of the system would provide important information on the thermal state of the donor as well as useful insight into the thermal properties of the primary star and the accretion disk.

  13. Similar performance of Brasfield and Wisconsin scoring systems in young children with cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Cleveland, Robert H.; Stamoulis, Catherine [Boston Children' s Hospital, Harvard Medical School, Department of Radiology, Boston, MA (United States); Sawicki, Gregory S. [Boston Children' s Hospital, Harvard Medical School, Division of Respiratory Diseases, Department of Medicine, Boston, MA (United States)

    2015-10-15

    To assess the severity of lung disease in cystic fibrosis (CF), scoring systems based on chest radiographs (CXRs), CT and MRI have been used extensively, although primarily in research settings rather than for clinical purposes. It has recently been shown that those based on CXRs (primarily the Brasfield and Wisconsin systems) are as sensitive and valid as those based on CT. The reproducibility and correlation of both systems to pulmonary function tests (PFTs) were recently investigated and were found to be statistically identical. However, the relative performance of these systems has not been specifically assessed in children younger than 5 years old with mild lung disease, a critical age range in which PFTs is rarely performed. To investigate and compare the performance of the Brasfield and Wisconsin systems in children 0-5 years old with predominantly mild lung disease. Fifty-five patients 0-5 years old with 105 CXRs were included in the study. Given that the goal was to compare system performance in mild disease, only the first two CXRs from each patient were included (all but five patients had two images). When only one image was available in the target age range, it only was included. Agreement between the Brasfield and Wisconsin systems was assessed using a 2X2 contingency table assuming binary classification of CF lung disease using CXR scoring systems (mild vs. non-mild). In the absence of PFTs or another external gold standard for comparison, the Wisconsin system was used as an arbitrary gold standard against which the Brasfield was compared. Correlation between the two systems was assessed via a concordance correlation coefficient (CCC) for repeated measures. Scores were rated as mild or non-mild based on published numerical cutoffs for each system. The systems agreed on 89/105 (85%) and disagreed on 16/105 (15%) of the CXRs. Agreement between the two systems was statistically significant (P < 0.001). Relative sensitivity and specificity of the

  14. A Score Function for Optimizing the Cycle-Life of Battery-Powered Embedded Systems

    DEFF Research Database (Denmark)

    Wognsen, Erik Ramsgaard; Haverkort, Boudewijn; Jongerden, Marijn

    2015-01-01

    An ever increasing share of embedded systems is powered by rechargeable batteries. These batteries deteriorate with the number of charge/discharge cycles they are subjected to, the so-called cycle life. In this paper, we propose the wear score function to compare and evaluate the relative impact...... of usage (charge and discharge) profiles on cycle life. The wear score function can not only be used to rank different usage profiles, these rankings can also be used as a criterion for optimizing the overall lifetime of a battery-powered system. We perform such an optimization on a nano-satellite case...... checking and reinforcement learning to synthesize near-optimal scheduling strategies subject to possible hard timing-constaints. We use this to study the trade-off between optimal short-term dynamic payload selection and the operational life of the satellite....

  15. The urgent need for a harmonized severity scoring system for acute allergic reactions

    DEFF Research Database (Denmark)

    Muraro, Antonella; Fernandez-Rivas, Montserrat; Beyer, Kirsten

    2018-01-01

    The accurate assessment and communication of the severity of acute allergic reactions is important to patients, clinicians, researchers, the food industry, public health and regulatory authorities. Severity has different meanings to different stakeholders with patients and clinicians rating...... of different stakeholder groups. We propose a novel approach to develop and then validate a harmonized scoring system for acute allergic reactions, based on a data-driven method that is informed by clinical and patient experience and other stakeholders' perspectives. We envisage two formats: (i) a numerical...... the significance of particular symptoms very differently. Many severity scoring systems have been generated, most focusing on the severity of reactions following exposure to a limited group of allergens. They are heterogeneous in format, none has used an accepted developmental approach and none has been validated...

  16. Comparison of scoring systems for nonvariceal upper gastrointestinal bleeding: a multicenter prospective cohort study.

    Science.gov (United States)

    Yang, Hae Min; Jeon, Seong Woo; Jung, Jin Tae; Lee, Dong Wook; Ha, Chang Yoon; Park, Kyung Sik; Lee, Si Hyung; Yang, Chang Heon; Park, Jun Hyung; Park, Youn Sun

    2016-01-01

    The Glasgow-Blatchford score (GBS) and Rockall score (RS) are widely used to assess risk in patients with upper gastrointestinal bleeding (UGIB). We compared both scoring systems and evaluated their clinical usefulness. Between February 2011 and December 2013, 1584 patients with nonvariceal UGIB were included in the study. A prospective study was conducted to compare the performance of the GBS, pre-RS, and full RS. We compared the performance of these scores using receiver operating characteristic curves. For prediction of the need for hospital-based intervention, the GBS was similar to the full RS (area under the receiver operating characteristic curves [AUROC] 0.705 vs 0.727; P = 0.282) and superior to the pre-RS (AUROC 0.705 vs 0.601; P < 0.0001). In predicting death, the full RS was superior to the GBS (AUROC 0.758 vs 0.644; P = 0.0006) and similar to the pre-RS (AUROC 0.758 vs 0.754; P = 0.869). In predicting rebleeding, the full RS was superior to both GBS (AUROC 0.642 vs 0.585; P = 0.031) and pre-RS (AUROC 0.642 vs 0.593; P = 0.0003). Of 1584 patients, 13 (0.8%) scored 0 on the GBS. Therapeutic intervention was not performed in any of these patients. The GBS is more useful than the pre-RS for predicting the need for hospital-based intervention. A cutoff value of 0 for low-risk patients who might be suitable for outpatient management is useful. The full RS is helpful in predicting death. None of the systems accurately predict rebleeding with a low AUROC. ( cris.nih.go.kr/KCT0000514). © 2015 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  17. Charge separation and carrier dynamics in donor-acceptor heterojunction photovoltaic systems.

    Science.gov (United States)

    Teuscher, Joël; Brauer, Jan C; Stepanov, Andrey; Solano, Alicia; Boziki, Ariadni; Chergui, Majed; Wolf, Jean-Pierre; Rothlisberger, Ursula; Banerji, Natalie; Moser, Jacques-E

    2017-11-01

    Electron transfer and subsequent charge separation across donor-acceptor heterojunctions remain the most important areas of study in the field of third-generation photovoltaics. In this context, it is particularly important to unravel the dynamics of individual ultrafast processes (such as photoinduced electron transfer, carrier trapping and association, and energy transfer and relaxation), which prevail in materials and at their interfaces. In the frame of the National Center of Competence in Research "Molecular Ultrafast Science and Technology," a research instrument of the Swiss National Science Foundation, several groups active in the field of ultrafast science in Switzerland have applied a number of complementary experimental techniques and computational simulation tools to scrutinize these critical photophysical phenomena. Structural, electronic, and transport properties of the materials and the detailed mechanisms of photoinduced charge separation in dye-sensitized solar cells, conjugated polymer- and small molecule-based organic photovoltaics, and high-efficiency lead halide perovskite solar energy converters have been scrutinized. Results yielded more than thirty research articles, an overview of which is provided here.

  18. Donor-specific antibodies require preactivated immune system to harm renal transplant.

    Science.gov (United States)

    Süsal, Caner; Döhler, Bernd; Ruhenstroth, Andrea; Morath, Christian; Slavcev, Antonij; Fehr, Thomas; Wagner, Eric; Krüger, Bernd; Rees, Margaret; Balen, Sanja; Živčić-Ćosić, Stela; Norman, Douglas J; Kuypers, Dirk; Emonds, Marie-Paule; Pisarski, Przemyslaw; Bösmüller, Claudia; Weimer, Rolf; Mytilineos, Joannis; Scherer, Sabine; Tran, Thuong H; Gombos, Petra; Schemmer, Peter; Zeier, Martin; Opelz, Gerhard

    2016-07-01

    It is an unresolved issue why some kidney transplant recipients with pretransplant donor-specific HLA antibodies (DSA) show a high transplant failure rate, whereas in other patients DSA do not harm the graft. We investigated whether help from preactivated T-cells might be necessary for DSA to exert a deleterious effect. The impact of pretransplant DSA and immune activation marker soluble CD30 (sCD30) on 3-year graft survival was analyzed in 385 presensitized kidney transplant recipients. A deleterious influence of pretransplant DSA on graft survival was evident only in patients who were positive for the immune activation marker sCD30. In the absence of sCD30 positivity, 3-year graft survival was virtually identical in patients with or without DSA (83.1±3.9% and 84.3±2.8%, P=0.81). A strikingly lower 3-year graft survival rate of 62.1±6.4% was observed in patients who were both sCD30 and DSA positive (HR 2.92, PsCD30 negative. Pretransplant DSA have a significantly deleterious impact on graft survival only in the presence of high pretransplant levels of the activation marker sCD30. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Charge separation and carrier dynamics in donor-acceptor heterojunction photovoltaic systems

    Directory of Open Access Journals (Sweden)

    Joël Teuscher

    2017-11-01

    Full Text Available Electron transfer and subsequent charge separation across donor-acceptor heterojunctions remain the most important areas of study in the field of third-generation photovoltaics. In this context, it is particularly important to unravel the dynamics of individual ultrafast processes (such as photoinduced electron transfer, carrier trapping and association, and energy transfer and relaxation, which prevail in materials and at their interfaces. In the frame of the National Center of Competence in Research “Molecular Ultrafast Science and Technology,” a research instrument of the Swiss National Science Foundation, several groups active in the field of ultrafast science in Switzerland have applied a number of complementary experimental techniques and computational simulation tools to scrutinize these critical photophysical phenomena. Structural, electronic, and transport properties of the materials and the detailed mechanisms of photoinduced charge separation in dye-sensitized solar cells, conjugated polymer- and small molecule-based organic photovoltaics, and high-efficiency lead halide perovskite solar energy converters have been scrutinized. Results yielded more than thirty research articles, an overview of which is provided here.

  20. Comparison of Glasgow-Blatchford score and full Rockall score systems to predict clinical outcomes in patients with upper gastrointestinal bleeding.

    Science.gov (United States)

    Mokhtare, Marjan; Bozorgi, Vida; Agah, Shahram; Nikkhah, Mehdi; Faghihi, Amirhossein; Boghratian, Amirhossein; Shalbaf, Neda; Khanlari, Abbas; Seifmanesh, Hamidreza

    2016-01-01

    Various risk scoring systems have been recently developed to predict clinical outcomes in patients with upper gastrointestinal bleeding (UGIB). The two commonly used scoring systems include full Rockall score (RS) and the Glasgow-Blatchford score (GBS). Bleeding scores were assessed in terms of prediction of clinical outcomes in patients with UGIB. Two hundred patients (age >18 years) with obvious symptoms of UGIB in the emergency department of Rasoul Akram Hospital were enrolled. Full RS and GBS were calculated. We followed the patients for records of rebleeding and 1-month mortality. A receiver operating characteristic curve by using areas under the curve (AUCs) was used to statistically identify the best cutoff point. Eighteen patients were excluded from the study due to failure to follow-up. Rebleeding and mortality rate were 9.34% (n=17) and 11.53% (n=21), respectively. Regarding 1-month mortality, full RS was better than GBS (AUC, 0.648 versus 0.582; P =0.021). GBS was more accurate in terms of detecting transfusion need (AUC, 0.757 versus 0.528; P =0.001), rebleeding rate (AUC, 0.722 versus 0.520; P =0.002), intensive care unit admission rate (AUC, 0.648 versus 0.582; P =0.021), and endoscopic intervention rate (AUC, 0.771 versus 0.650; P <0.001). We found the full RS system is better for 1-month mortality prediction while GBS system is better for prediction of other outcomes.

  1. Development and validation of a surgical-pathologic staging and scoring system for cervical cancer.

    Science.gov (United States)

    Li, Shuang; Li, Xiong; Zhang, Yuan; Zhou, Hang; Tang, Fangxu; Jia, Yao; Hu, Ting; Sun, Haiying; Yang, Ru; Chen, Yile; Cheng, Xiaodong; Lv, Weiguo; Wu, Li; Zhou, Jin; Wang, Shaoshuai; Huang, Kecheng; Wang, Lin; Yao, Yuan; Yang, Qifeng; Yang, Xingsheng; Zhang, Qinghua; Han, Xiaobing; Lin, Zhongqiu; Xing, Hui; Qu, Pengpeng; Cai, Hongbing; Song, Xiaojie; Tian, Xiaoyu; Shen, Jian; Xi, Ling; Li, Kezhen; Deng, Dongrui; Wang, Hui; Wang, Changyu; Wu, Mingfu; Zhu, Tao; Chen, Gang; Gao, Qinglei; Wang, Shixuan; Hu, Junbo; Kong, Beihua; Xie, Xing; Ma, Ding

    2016-04-12

    Most cervical cancer patients worldwide receive surgical treatments, and yet the current International Federation of Gynecology and Obstetrics (FIGO) staging system do not consider surgical-pathologic data. We propose a more comprehensive and prognostically valuable surgical-pathologic staging and scoring system (SPSs). Records from 4,220 eligible cervical cancer cases (Cohort 1) were screened for surgical-pathologic risk factors. We constructed a surgical-pathologic staging and SPSs, which was subsequently validated in a prospective study of 1,104 cervical cancer patients (Cohort 2). In Cohort 1, seven independent risk factors were associated with patient outcome: lymph node metastasis (LNM), parametrial involvement, histological type, grade, tumor size, stromal invasion, and lymph-vascular space invasion (LVSI). The FIGO staging system was revised and expanded into a surgical-pathologic staging system by including additional criteria of LNM, stromal invasion, and LVSI. LNM was subdivided into three categories based on number and location of metastases. Inclusion of all seven prognostic risk factors improves practical applicability. Patients were stratified into three SPSs risk categories: zero-, low-, and high-score with scores of 0, 1 to 3, and ≥4 (P=1.08E-45; P=6.15E-55). In Cohort 2, 5-year overall survival (OS) and disease-free survival (DFS) outcomes decreased with increased SPSs scores (P=9.04E-15; P=3.23E-16), validating the approach. Surgical-pathologic staging and SPSs show greater homogeneity and discriminatory utility than FIGO staging. Surgical-pathologic staging and SPSs improve characterization of tumor severity and disease invasion, which may more accurately predict outcome and guide postoperative therapy.

  2. A validated clinical MRI injury scoring system in neonatal hypoxic-ischemic encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Trivedi, Shamik B.; Vesoulis, Zachary A.; Rao, Rakesh; Liao, Steve M.; Mathur, Amit M. [Washington University School of Medicine, Division of Newborn Medicine, Edward Mallinckrodt Department of Pediatrics, St. Louis, MO (United States); Shimony, Joshua S.; McKinstry, Robert C. [Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, MO (United States)

    2017-10-15

    Deep nuclear gray matter injury in neonatal hypoxic-ischemic encephalopathy (HIE) is associated with worse neurodevelopmental outcomes. We previously published a qualitative MRI injury scoring system utilizing serial T1-weighted, T2-weighted and diffusion-weighted imaging (DWI), weighted for deep nuclear gray matter injury. To establish the validity of the MRI scoring system with neurodevelopmental outcome at 18-24 months. MRI scans from neonates with moderate to severe HIE treated with therapeutic hypothermia were evaluated. Signal abnormality was scored on T1-weighted, T2-weighted and DWI sequences and assessed using an established system in five regions: (a) subcortical: caudate nucleus, globus pallidus and putamen, thalamus and the posterior limb of the internal capsule; (b) white matter; (c) cortex, (d) cerebellum and (e) brainstem. MRI injury was graded as none, mild, moderate or severe. Inter-rater reliability was tested on a subset of scans by two independent and blinded neuroradiologists. Surviving infants underwent the Bayley Scales of Infant and Toddler Development-III (Bayley-III) at 18-24 months. Data were analyzed using univariate and multivariate linear and logistic regression. Fifty-seven eligible neonates underwent at least one MRI scan in the first 2 weeks of life. Mean postnatal age at scan 1 was 4±2 days in 50/57 (88%) neonates and 48/54 (89%) surviving infants underwent scan 2 at 10±2 days. In 54/57 (95%) survivors, higher MRI injury grades were significantly associated with worse outcomes in the cognitive, motor and language domains of the Bayley-III. A qualitative MRI injury scoring system weighted for deep nuclear gray matter injury is a significant predictor of neurodevelopmental outcome at 18-24 months in neonates with HIE. (orig.)

  3. AN EXCEL-BASED DECISION SUPPORT SYSTEM FOR SCORING AND RANKING PROPOSED R&D PROJECTS

    OpenAIRE

    ANNE DE PIANTE HENRIKSEN; SUSAN W. PALOCSAY

    2008-01-01

    One of the most challenging aspects of technology management is the selection of research and development (R&D) projects from among a group of proposals. This paper introduces an interactive, user-friendly decision support system for evaluating and ranking R&D projects and demonstrates its application on an example R&D program. It employs the scoring methodology developed by Henriksen and Traynor to provide a practical technique that considers both project merit and project cost in the evalua...

  4. A validated clinical MRI injury scoring system in neonatal hypoxic-ischemic encephalopathy

    International Nuclear Information System (INIS)

    Trivedi, Shamik B.; Vesoulis, Zachary A.; Rao, Rakesh; Liao, Steve M.; Mathur, Amit M.; Shimony, Joshua S.; McKinstry, Robert C.

    2017-01-01

    Deep nuclear gray matter injury in neonatal hypoxic-ischemic encephalopathy (HIE) is associated with worse neurodevelopmental outcomes. We previously published a qualitative MRI injury scoring system utilizing serial T1-weighted, T2-weighted and diffusion-weighted imaging (DWI), weighted for deep nuclear gray matter injury. To establish the validity of the MRI scoring system with neurodevelopmental outcome at 18-24 months. MRI scans from neonates with moderate to severe HIE treated with therapeutic hypothermia were evaluated. Signal abnormality was scored on T1-weighted, T2-weighted and DWI sequences and assessed using an established system in five regions: (a) subcortical: caudate nucleus, globus pallidus and putamen, thalamus and the posterior limb of the internal capsule; (b) white matter; (c) cortex, (d) cerebellum and (e) brainstem. MRI injury was graded as none, mild, moderate or severe. Inter-rater reliability was tested on a subset of scans by two independent and blinded neuroradiologists. Surviving infants underwent the Bayley Scales of Infant and Toddler Development-III (Bayley-III) at 18-24 months. Data were analyzed using univariate and multivariate linear and logistic regression. Fifty-seven eligible neonates underwent at least one MRI scan in the first 2 weeks of life. Mean postnatal age at scan 1 was 4±2 days in 50/57 (88%) neonates and 48/54 (89%) surviving infants underwent scan 2 at 10±2 days. In 54/57 (95%) survivors, higher MRI injury grades were significantly associated with worse outcomes in the cognitive, motor and language domains of the Bayley-III. A qualitative MRI injury scoring system weighted for deep nuclear gray matter injury is a significant predictor of neurodevelopmental outcome at 18-24 months in neonates with HIE. (orig.)

  5. Translation and validation of the Dutch new Knee Society Scoring System ©.

    Science.gov (United States)

    Van Der Straeten, Catherine; Witvrouw, Erik; Willems, Tine; Bellemans, Johan; Victor, Jan

    2013-11-01

    A new version of The Knee Society Knee Scoring System(©) (KSS) has recently been developed. Before this scale can be used in non-English-speaking populations, it has to be translated and validated for a particular population. We evaluated the construct and content validity, the test-retest reliability, and the internal consistency of the Dutch version of the New Knee Society KSS. A Dutch translation was performed using a forward-backward translation protocol. We tested the construct validity of the Dutch New KSS by comparing it with the Dutch versions of the WOMAC, Knee Injury and Osteoarthritis Outcome Score (KOOS), and SF-12 scores in 137 patients undergoing total knee arthroplasty (TKA). Content validity was assessed by comparing pre- and postoperative scores and by checking floor and ceiling effects. To evaluate test-retest reliability and consistency, 47 patients completed the questionnaire a second time with a mean of 8 days interval (range, 2-20 days) between tests. Construct validity was demonstrated because the Dutch New KSS correlated well with the Dutch WOMAC (r = -0.751; p Dutch KOOS (r = -0.723; p Dutch SF-12 (r = 0.569; p Dutch New KSS is an excellent instrument to evaluate TKA outcome in Dutch-speaking patients.

  6. A simple scoring system for breast MRI interpretation: does it compensate for reader experience?

    International Nuclear Information System (INIS)

    Marino, Maria Adele; Clauser, Paola; Woitek, Ramona; Wengert, Georg J.; Kapetas, Panagiotis; Bernathova, Maria; Pinker-Domenig, Katja; Helbich, Thomas H.; Baltzer, Pascal A.T.; Preidler, Klaus

    2016-01-01

    To investigate the impact of a scoring system (Tree) on inter-reader agreement and diagnostic performance in breast MRI reading. This IRB-approved, single-centre study included 100 patients with 121 consecutive histopathologically verified lesions (52 malignant, 68 benign). Four breast radiologists with different levels of MRI experience and blinded to histopathology retrospectively evaluated all examinations. Readers independently applied two methods to classify breast lesions: BI-RADS and Tree. BI-RADS provides a reporting lexicon that is empirically translated into likelihoods of malignancy; Tree is a scoring system that results in a diagnostic category. Readings were compared by ROC analysis and kappa statistics. Inter-reader agreement was substantial to almost perfect (kappa: 0.643-0.896) for Tree and moderate (kappa: 0.455-0.657) for BI-RADS. Diagnostic performance using Tree (AUC: 0.889-0.943) was similar to BI-RADS (AUC: 0.872-0.953). Less experienced radiologists achieved AUC: improvements up to 4.7 % using Tree (P-values: 0.042-0.698); an expert's performance did not change (P = 0.526). The least experienced reader improved in specificity using Tree (16 %, P = 0.001). No further sensitivity and specificity differences were found (P > 0.1). The Tree scoring system improves inter-reader agreement and achieves a diagnostic performance similar to that of BI-RADS. Less experienced radiologists, in particular, benefit from Tree. (orig.)

  7. Intelligibility in microbial complex systems: Wittgenstein and the score of life.

    Science.gov (United States)

    Baquero, Fernando; Moya, Andrés

    2012-01-01

    Knowledge in microbiology is reaching an extreme level of diversification and complexity, which paradoxically results in a strong reduction in the intelligibility of microbial life. In our days, the "score of life" metaphor is more accurate to express the complexity of living systems than the classic "book of life." Music and life can be represented at lower hierarchical levels by music scores and genomic sequences, and such representations have a generational influence in the reproduction of music and life. If music can be considered as a representation of life, such representation remains as unthinkable as life itself. The analysis of scores and genomic sequences might provide mechanistic, phylogenetic, and evolutionary insights into music and life, but not about their real dynamics and nature, which is still maintained unthinkable, as was proposed by Wittgenstein. As complex systems, life or music is composed by thinkable and only showable parts, and a strategy of half-thinking, half-seeing is needed to expand knowledge. Complex models for complex systems, based on experiences on trans-hierarchical integrations, should be developed in order to provide a mixture of legibility and imageability of biological processes, which should lead to higher levels of intelligibility of microbial life.

  8. Comparison of a classical with a highly formularized body condition scoring system for dairy cattle.

    Science.gov (United States)

    Isensee, A; Leiber, F; Bieber, A; Spengler, A; Ivemeyer, S; Maurer, V; Klocke, P

    2014-12-01

    Body condition scoring is a common tool to assess the subcutaneous fat reserves of dairy cows. Because of its subjectivity, which causes limits in repeatability, it is often discussed controversially. Aim of the current study was to evaluate the impact of considering the cows overall appearance on the scoring process and on the validity of the results. Therefore, two different methods to reveal body condition scores (BCS), 'independent BCS' (iBCS) and 'dependent BCS' (dBCS), were used to assess 1111 Swiss Brown Cattle. The iBCS and the dBCS systems were both working with the same flowchart with a decision tree structure for visual and palpatory assessment using a scale from 2 to 5 with increment units of 0.25. The iBCS was created strictly complying with the defined frames of the decision tree structure. The system was chosen due to its formularized approach to reduce the influence of subjective impressions. By contrast, the dBCS system, which was in line with common practice, had a more open approach, where - besides the decision tree - the overall impression of the cow's physical appearance was taken into account for generating the final score. Ultrasound measurement of the back fat thickness (BFT) was applied as a validation method. The dBCS turned out to be the better predictor of BFT, explaining 67.3% of the variance. The iBCS was only able to explain 47.3% of the BFT variance. Within the whole data set, only 31.3% of the animals received identical dBCS and iBCS. The pin bone region caused the most deviations between dBCS and iBCS, but also assessing the pelvis line, the hook bones and the ligaments led to divergences in around 20% of the scored animals. The study showed that during the assessment of body condition a strict adherence to a decision tree is a possible source of inexact classifications. Some body regions, especially the pin bones, proved to be particularly challenging for scoring due to difficulties in assessing them. All the more, the inclusion

  9. Dynamic Measurement of Disease Activity in Acute Pancreatitis: The Pancreatitis Activity Scoring System.

    Science.gov (United States)

    Wu, Bechien U; Batech, Michael; Quezada, Michael; Lew, Daniel; Fujikawa, Kelly; Kung, Jonathan; Jamil, Laith H; Chen, Wansu; Afghani, Elham; Reicher, Sonya; Buxbaum, James; Pandol, Stephen J

    2017-07-01

    Acute pancreatitis has a highly variable course. Currently there is no widely accepted method to measure disease activity in patients hospitalized for acute pancreatitis. We aimed to develop a clinical activity index that incorporates routine clinical parameters to assist in the measurement, study, and management of acute pancreatitis. We used the UCLA/RAND appropriateness method to identify items for inclusion in the disease activity instrument. We conducted a systematic literature review followed by two sets of iterative modified Delphi meetings including a panel of international experts between November 2014 and November 2015. The final instrument was then applied to patient data obtained from five separate study cohorts across Southern California to assess profiles of disease activity. From a list of 35 items comprising 6 domains, we identified 5 parameters for inclusion in the final weighted clinical activity scoring system: organ failure, systemic inflammatory response syndrome, abdominal pain, requirement for opiates and ability to tolerate oral intake. We applied the weighted scoring system across the 5 study cohorts comprising 3,123 patients. We identified several distinct patterns of disease activity: (i) overall there was an elevated score at baseline relative to discharge across all study cohorts, (ii) there were distinct patterns of disease activity related to duration of illness as well as (iii) early and persistent elevation of disease activity among patients with severe acute pancreatitis defined as persistent organ failure. We present the development and initial validation of a clinical activity score for real-time assessment of disease activity in patients with acute pancreatitis.

  10. Red cell distribution width and neurological scoring systems in acute stroke patients

    Directory of Open Access Journals (Sweden)

    Kara H

    2015-03-01

    Full Text Available Hasan Kara,1 Selim Degirmenci,1 Aysegul Bayir,1 Ahmet Ak,1 Murat Akinci,1 Ali Dogru,1 Fikret Akyurek,2 Seyit Ali Kayis3 1Department of Emergency Medicine, Faculty of Medicine, Selcuk University, Konya, Turkey; 2Department of Biochemistry, Faculty of Medicine, Selcuk University, Konya, Turkey; 3Department of Biostatistics, Faculty of Medicine, Karabuk University, Karabuk, Turkey Objectives: The purpose of the present study was to evaluate the association between the red blood cell distribution width (RDW and the Glasgow Coma Scale (GCS, Canadian Neurological Scale (CNS, and National Institutes of Health Stroke Scale (NIHSS scores in patients who had acute ischemic stroke. Methods: This prospective observational cohort study included 88 patients who have had acute ischemic stroke and a control group of 40 patients who were evaluated in the Emergency Department for disorders other than acute ischemic stroke. All subjects had RDW determined, and stroke patients had scoring with the GCS, CNS, and NIHSS scores. The GCS, CNS, and NIHSS scores of the patients were rated as mild, moderate, or severe and compared with RDW. Results: Stroke patients had significantly higher median RDW than control subjects. The median RDW values were significantly elevated in patients who had more severe rather than milder strokes rated with all three scoring systems (GCS, CNS, and NIHSS. The median RDW values were significantly elevated for patients who had moderate rather than mild strokes rated by GCS and CNS and for patients who had severe rather than mild strokes rated by NIHSS. The area under the receiver operating characteristic curve was 0.760 (95% confidence interval, 0.676–0.844. Separation of stroke patients and control groups was optimal with RDW 14% (sensitivity, 71.6%; specificity, 67.5%; accuracy, 70.3%. Conclusion: In stroke patients who have symptoms <24 hours, the RDW may be useful in predicting the severity and functional outcomes of the stroke

  11. Multiparametric MRI of the prostate: diagnostic performance and interreader agreement of two scoring systems.

    Science.gov (United States)

    Lin, Wei-Ching; Muglia, Valdair F; Silva, Gyl E B; Chodraui Filho, Salomão; Reis, Rodolfo B; Westphalen, Antonio C

    2016-06-01

    To compare the diagnostic accuracies and interreader agreements of the Prostate Imaging Reporting and Data System (PI-RADS) v. 2 and University of California San Francisco (UCSF) multiparametric prostate MRI scale for diagnosing clinically significant prostate cancer. This institutional review board-approved retrospective study included 49 males who had 1.5 T endorectal MRI and prostatectomy. Two radiologists scored suspicious lesions on MRI using PI-RADS v. 2 and the UCSF scale. Percent agreement, 2 × 2 tables and the area under the receiver operating characteristic curves (Az) were used to assess and compare the individual and overall scores of these scales. Interreader agreements were estimated with kappa statistics. Reader 1 (R1) detected 78 lesions, and Reader 2 (R2) detected 80 lesions. Both identified 52 of 65 significant cancers. The Az for PI-RADS v. 2 and UCSF scale for R1 were 0.68 and 0.69 [T2 weighted imaging (T2WI)], 0.75 and 0.68 [diffusion-weighted imaging (DWI)] and 0.64 and 0.72 (overall score), respectively, and were 0.72 and 0.75 (T2WI), 0.73 and 0.67 (DWI) and 0.66 and 0.75 (overall score) for R2. The dynamic contrast-enhanced percent agreements between scales were 100% (R1) and 95% (R2). PI-RADS v. 2 DWI of R1 performed better than UCSF DWI (Az = 0.75 vs Az = 0.68; p = 0.05); no other differences were found. The interreader agreements were higher for PI-RADS v. 2 (T2WI: 0.56 vs 0.42; DWI: 0.60 vs 0.46; overall: 0.61 vs 0.42). The UCSF approach to derive the overall PI-RADS v. 2 scores increased the Az for the identification of significant cancer (R1 to 0.76, p < 0.05; R2 to 0.71, p = 0.35). Although PI-RADS v. 2 DWI score may have a higher discriminatory performance than the UCSF scale counterpart to diagnose clinically significant cancer, the utilization of the UCSF scale weighing system for the integration of PI-RADS v. 2 individual parameter scores improved the accuracy its overall score. PI-RADS v. 2 is

  12. Interplay between barrier width and height in electron tunneling: photoinduced electron transfer in porphyrin-based donor-bridge-acceptor systems.

    Science.gov (United States)

    Pettersson, Karin; Wiberg, Joanna; Ljungdahl, Thomas; Mårtensson, Jerker; Albinsson, Bo

    2006-01-12

    The rate of electron tunneling in molecular donor-bridge-acceptor (D-B-A) systems is determined both by the tunneling barrier width and height, that is, both by the distance between the donor and acceptor as well as by the energy gap between the donor and bridge moieties. These factors are therefore important to control when designing functional electron transfer systems, such as constructs for photovoltaics, artificial photosynthesis, and molecular scale electronics. In this paper we have investigated a set of D-B-A systems in which the distance and the energy difference between the donor and bridge states (DeltaEDB) are systematically varied. Zinc(II) and gold(III) porphyrins were chosen as electron donor and acceptor because of their suitable driving force for photoinduced electron transfer (-0.9 eV in butyronitrile) and well-characterized photophysics. We have previously shown, in accordance with the superexchange mechanism for electron transfer, that the electron transfer rate is proportional to the inverse of DeltaEDB in a series of zinc/gold porphyrin D-B-A systems with bridges of constant edge to edge distance (19.6 A) and varying DeltaEDB (3900-17 600 cm(-1)). Here, we use the same donor and acceptor but the bridge is shortened or extended giving a set of oligo-p-phenyleneethynylene bridges (OPE) with four different edge to edge distances ranging from 12.7 to 33.4 A. These two sets of D-B-A systems-ZnP-RB-AuP+ and ZnP-nB-AuP+-have one bridge in common, and hence, for the first time both the distance and DeltaEDB dependence of electron transfer can be studied simultaneously in a systematic way.

  13. An Objective Balance Error Scoring System for Sideline Concussion Evaluation Using Duplex Kinect Sensors

    Directory of Open Access Journals (Sweden)

    Mengqi Zhu

    2017-10-01

    Full Text Available Sports-related concussion is a common sports injury that might induce potential long-term consequences without early diagnosis and intervention in the field. However, there are few options of such sensor systems available. The aim of the study is to propose and validate an automated concussion administration and scoring approach, which is objective, affordable and capable of detecting all balance errors required by the balance error scoring system (BESS protocol in the field condition. Our approach is first to capture human body skeleton positions using two Microsoft Kinect sensors in the proposed configuration and merge the data by a custom-made algorithm to remove the self-occlusion of limbs. The standing balance errors according to BESS protocol were further measured and accessed automatically by the proposed algorithm. Simultaneously, the BESS test was filmed for scoring by an experienced rater. Two results were compared using Pearson coefficient r, obtaining an excellent consistency (r = 0.93, p < 0.05. In addition, BESS test–retest was performed after seven days and compared using intraclass correlation coefficients (ICC, showing a good test–retest reliability (ICC = 0.81, p < 0.01. The proposed approach could be an alternative of objective tools to assess postural stability for sideline sports concussion diagnosis.

  14. Human umbilical cord derived mesenchymal stem cells promote interleukin-17 production from human peripheral blood mononuclear cells of healthy donors and systemic lupus erythematosus patients.

    Science.gov (United States)

    Ren, S; Hu, J; Chen, Y; Yuan, T; Hu, H; Li, S

    2016-03-01

    Inflammation instigated by interleukin (IL)-17-producing cells is central to the development and pathogenesis of several human autoimmune diseases and animal models of autoimmunity. The expansion of IL-17-producing cells from healthy donors is reportedly promoted by mesenchymal stem cells derived from fetal bone marrow. In the present study, human umbilical cord-derived mesenchymal stem cells (hUC-MSCs) were examined for their effects on lymphocytes from healthy donors and from patients with systemic lupus erythematosus (SLE). Significantly higher levels of IL-17 were produced when CD4(+) T cells from healthy donors were co-cultured with hUC-MSCs than those that were cultured alone. Blocking experiments identified that this effect might be mediated partially through prostaglandin E2 (PGE2 ) and IL-1β, without IL-23 involvement. We then co-cultured hUC-MSCs with human CD4(+) T cells from systemic lupus erythematosus patients. Ex-vivo inductions of IL-17 by hUC-MSCs in stimulated lymphocytes were significantly higher in SLE patients than in healthy donors. This effect was not observed for IL-23. Taken together, our results represent that hUC-MSCs can promote the IL-17 production from CD4(+) T cells in both healthy donor and SLE patients. PGE2 and IL-1β might also be partially involved in the promotive effect of hUC-MSCs. © 2015 British Society for Immunology.

  15. A novel scoring system to measure radiographic abnormalities and related spirometric values in cured pulmonary tuberculosis.

    Directory of Open Access Journals (Sweden)

    Renata Báez-Saldaña

    Full Text Available BACKGROUND: Despite chemotherapy, patients with cured pulmonary tuberculosis may result in lung functional impairment. OBJECTIVE: To evaluate a novel scoring system based on the degree of radiographic abnormalities and related spirometric values in patients with cured pulmonary tuberculosis. METHODS: One hundred and twenty seven patients with cured pulmonary tuberculosis were prospectively enrolled in a referral hospital specializing in respiratory diseases. Spirometry was performed and the extent of radiographic abnormalities was evaluated twice by each of two readers to generate a novel quantitative score. Scoring reproducibility was analyzed by the intra-class correlation coefficient (ICC and the Bland-Altman method. Multiple linear regression models were performed to assess the association of the extent of radiographic abnormalities with spirometric values. RESULTS: The intra-observer agreement for scoring of radiographic abnormalities (SRA showed an ICC of 0.81 (CI:95%, 0.67-0.95 and 0.78 (CI:95%, 0.65-0.92, for reader 1 and 2, respectively. Inter-observer reproducibility for the first measurement was 0.83 (CI:95%, 0.71-0.95, and for the second measurement was 0.74 (CI:95%, 0.58-0.90. The Bland-Altman analysis of the intra-observer agreement showed a mean bias of 0.87% and -0.55% and an inter-observer agreement of -0.35% and -1.78%, indicating a minor average systematic variability. After adjustment for age, gender, height, smoking status, pack-years of smoking, and degree of dyspnea, the scoring degree of radiographic abnormalities was significantly and negatively associated with absolute and percent predicted values of FVC: -0.07 (CI:95%, -0.01 to -0.04; -2.48 (CI:95%, -3.45 to -1.50; and FEV1 -0.07 (CI:95%, -0.10 to -0.05; -2.92 (CI:95%, -3.87 to -1.97 respectively, in the patients studied. CONCLUSION: The extent of radiographic abnormalities, as evaluated through our novel scoring system, was inversely associated with spirometric values

  16. A Novel Scoring System to Measure Radiographic Abnormalities and Related Spirometric Values in Cured Pulmonary Tuberculosis

    Science.gov (United States)

    Báez-Saldaña, Renata; López-Arteaga, Yesenia; Bizarrón-Muro, Alma; Ferreira-Guerrero, Elizabeth; Ferreyra-Reyes, Leticia; Delgado-Sánchez, Guadalupe; Cruz-Hervert, Luis Pablo; Mongua-Rodríguez, Norma; García-García, Lourdes

    2013-01-01

    Background Despite chemotherapy, patients with cured pulmonary tuberculosis may result in lung functional impairment. Objective To evaluate a novel scoring system based on the degree of radiographic abnormalities and related spirometric values in patients with cured pulmonary tuberculosis. Methods One hundred and twenty seven patients with cured pulmonary tuberculosis were prospectively enrolled in a referral hospital specializing in respiratory diseases. Spirometry was performed and the extent of radiographic abnormalities was evaluated twice by each of two readers to generate a novel quantitative score. Scoring reproducibility was analyzed by the intra-class correlation coefficient (ICC) and the Bland-Altman method. Multiple linear regression models were performed to assess the association of the extent of radiographic abnormalities with spirometric values. Results The intra-observer agreement for scoring of radiographic abnormalities (SRA) showed an ICC of 0.81 (CI:95%, 0.67–0.95) and 0.78 (CI:95%, 0.65–0.92), for reader 1 and 2, respectively. Inter-observer reproducibility for the first measurement was 0.83 (CI:95%, 0.71–0.95), and for the second measurement was 0.74 (CI:95%, 0.58–0.90). The Bland-Altman analysis of the intra-observer agreement showed a mean bias of 0.87% and -0.55% and an inter-observer agreement of -0.35% and -1.78%, indicating a minor average systematic variability. After adjustment for age, gender, height, smoking status, pack-years of smoking, and degree of dyspnea, the scoring degree of radiographic abnormalities was significantly and negatively associated with absolute and percent predicted values of FVC: -0.07 (CI:95%, -0.01 to -0.04); -2.48 (CI:95%, -3.45 to -1.50); and FEV1 -0.07 (CI:95%, -0.10 to -0.05); -2.92 (CI:95%, -3.87 to -1.97) respectively, in the patients studied. Conclusion The extent of radiographic abnormalities, as evaluated through our novel scoring system, was inversely associated with spirometric values, and

  17. Hip Inflammation MRI Scoring System (HIMRISS) to predict response to hyaluronic acid injection in hip osteoarthritis

    DEFF Research Database (Denmark)

    Deseyne, Nicolas; Conrozier, Thierry; Lellouche, Henri

    2018-01-01

    OBJECTIVE: To assess predictors of response, according to hip MRI inflammatory scoring system (HIMRISS), in a sample of patients with hip osteoarthritis (OA) treated by hyaluronic acid (HA) injection. METHOD: Sixty patients with hip OA were included. Clinical outcomes were assessed at baseline...... SP=0.97, sensitivity SN=0.39, and positive and negative predictive values of 0.91 and 0.64, respectively. CONCLUSION: HIMRISS is reliable for total scores and sub-domains. It permits identification of responders to HA injection in hip OA patients........64, 0.83 and 0.78. Associations between MRI features and clinical data were assessed. Logistic regression (univariate and multivariate) was used to explore associations between MRI features and response to HA injection, according to WOMAC50 response at three months. RESULTS: In total, 45.5% of patients...

  18. A Web-based Peer Assessment System for Assigning Student Scores in Cooperative Learning

    Directory of Open Access Journals (Sweden)

    Anon Sukstrienwong

    2017-11-01

    Full Text Available Working in groups has become increasingly important in order to develop students' skills. However, it can be more successful when peers cooperate and are involved in the assigned tasks. However, several educators firmly show disadvantages when all peers received the same reward, regardless of individual contribution. Some teachers also considering peer assessment to be time and effort consuming because preparation and monitoring are needed. In order to overcome these problems, we have developed a web-based peer assessment referred to as the ‘Scoring by Peer Assessment System’ (SPAS that allows teachers to set up the process of peer assessment, in order to assign scores that reflect the contribution of each student. Moreover, a web-based application allows students to evaluate their peers regarding their individual contribution where cooperative learning and peer assessment are used. The paper describes the system design and the implementation of our peer assessment application.

  19. Early warning scores: a sign of deterioration in patients and systems

    LENUS (Irish Health Repository)

    Fox, A

    2015-02-01

    The early warning score is a decision-making tool that has a simple design, yet its implementation in healthcare organisations is proving complex. This article reports the results of a survey that evaluated the nurses’ experiences of using the NEWS (National Early Warning Score) in an acute hospital in Ireland. Staff reported that the NEWS was easy to use, did not increase workload and enhanced their ability to identify deteriorating patients. However, they also identified problems related to doctors’ delayed response times, doctors lack of training in the use of the tool, and a failure by doctors to modify parameters for patients with chronic conditions. NEWS enhances nurses’ role in early detection of patient deterioration but delays in response times by doctors, exposes systematic flaws in healthcare. This suggests that it is not only an indicator of patient deterioration but also of deteriorating healthcare systems.

  20. New scoring system identifies kidney outcome with radiation therapy in acute renal allograft rejection

    International Nuclear Information System (INIS)

    Chen, Luci M.; Godinez, Juan; Thisted, Ronald A.; Woodle, E. Steve; Thistlewaite, J. Richard; Powers, Claire; Haraf, Daniel

    2000-01-01

    concomitant immunosuppressive therapy. Independent factors examined by Cox regression modeling were: gender (p 0.005), creatinine levels (p = 0.000), HLA-DR (p = 0.05), PRA-Maximum >70% (p = 0.014). Each factor was scored using integral coefficients to generate four different groups. The Kaplan-Meier survival analyzed by group produces an interpretable separation of the risk factors for graft loss. Conclusions: The outcome in patients treated with radiation therapy for acute renal graft rejection can be predicted by a novel scoring system. Patients with scores of three or less are able to achieve 100% renal graft salvage, while patients who have scores of 12 or higher are not able to be salvaged with the current radiation therapy regimen. Future studies should be directed toward identifying more effective treatment for patients who have a high score based on our criteria. The scoring system should be utilized to identify patients at risk who could benefit from radiation therapy. Further study with a randomized trial utilizing this scoring system is needed to confirm the validity of the scoring system in predicting graft survival and the efficacy of radiation in patients who receive radiation therapy for acute graft rejection

  1. Introducing the Evaluation Tools for HSE Management System Performance Using Balanced Score Card Model

    Directory of Open Access Journals (Sweden)

    Ali Mohammadi

    2016-12-01

    Full Text Available Background: The performance of the HSE units has various dimensions Leading to different performances. Thus, any industry should be capable of evaluating these systems. The aim of this study was to design a standard questionnaire in the field of performance evaluation of HSE management system employing Balanced Score Card model. Methods: In this study we, first determined the criteria to be evaluated in the framework of Balanced Score Card model based on the objectives and strategies of HSE Management System and existing standards, and then designed questions on every criterion. We used content validity and Cronbach's Alpha to determine the reliability and validity of the questionnaire. Results: The primary questionnaire was comprised of 126 questions some of which were omitted regarding the results obtained from the CVR and CVI values. We obtained the CVI average of environmental dimension to be 0.75 and its CVI average 0.71. Conclusion: With respect to the results of the reliability and validity of this questionnaire,and its standardized design we can suggest using it for evaluation of HSE management system performance in organizations and industries with the mentioned system.

  2. Clock Drawing Test and the diagnosis of amnestic mild cognitive impairment: can more detailed scoring systems do the work?

    Science.gov (United States)

    Rubínová, Eva; Nikolai, Tomáš; Marková, Hana; Siffelová, Kamila; Laczó, Jan; Hort, Jakub; Vyhnálek, Martin

    2014-01-01

    The Clock Drawing Test is a frequently used cognitive screening test with several scoring systems in elderly populations. We compare simple and complex scoring systems and evaluate the usefulness of the combination of the Clock Drawing Test with the Mini-Mental State Examination to detect patients with mild cognitive impairment. Patients with amnestic mild cognitive impairment (n = 48) and age- and education-matched controls (n = 48) underwent neuropsychological examinations, including the Clock Drawing Test and the Mini-Mental State Examination. Clock drawings were scored by three blinded raters using one simple (6-point scale) and two complex (17- and 18-point scales) systems. The sensitivity and specificity of these scoring systems used alone and in combination with the Mini-Mental State Examination were determined. Complex scoring systems, but not the simple scoring system, were significant predictors of the amnestic mild cognitive impairment diagnosis in logistic regression analysis. At equal levels of sensitivity (87.5%), the Mini-Mental State Examination showed higher specificity (31.3%, compared with 12.5% for the 17-point Clock Drawing Test scoring scale). The combination of Clock Drawing Test and Mini-Mental State Examination scores increased the area under the curve (0.72; p Drawing Test did not differentiate between healthy elderly and patients with amnestic mild cognitive impairment in our sample. Complex scoring systems were slightly more efficient, yet still were characterized by high rates of false-positive results. We found psychometric improvement using combined scores from the Mini-Mental State Examination and the Clock Drawing Test when complex scoring systems were used. The results of this study support the benefit of using combined scores from simple methods.

  3. Comparison of severity of illness scoring systems in the prediction of hospital mortality in severe sepsis and septic shock

    Directory of Open Access Journals (Sweden)

    Crowe Colleen

    2010-01-01

    Full Text Available Background : New scoring systems, including the Rapid Emergency Medicine Score (REMS, the Mortality in Emergency Department Sepsis (MEDS score, and the confusion, urea nitrogen, respiratory rate, blood pressure, 65 years and older (CURB-65 score, have been developed for emergency department (ED use in various patient populations. Increasing use of early goal directed therapy (EGDT for the emergent treatment of sepsis introduces a growing population of patients in which the accuracy of these scoring systems has not been widely examined. Objectives : To evaluate the ability of the REMS, MEDS score, and CURB-65 score to predict mortality in septic patients treated with modified EGDT. Materials and Methods : Secondary analysis of data from prospectively identified patients treated with modified EGDT in a large tertiary care suburban community hospital with over 85,000 ED visits annually and 700 inpatient beds, from May 2007 through May 2008. We included all patients with severe sepsis or septic shock, who were treated with our modified EGDT protocol. Our major outcome was in-hospital mortality. The performance of the scores was compared by area under the ROC curves (AUCs. Results : A total of 216 patients with severe sepsis or septic shock were treated with modified EGDT during the study period. Overall mortality was 32.9%. Calculated AUCs were 0.74 [95% confidence interval (CI: 0.67-0.81] for the MEDS score, 0.62 (95% CI: 0.54-0.69 for the REMS, and 0.59 (95% CI: 0.51-0.67 for the CURB-65 score. Conclusion : We found that all three ED-based systems for scoring severity of illness had low to moderate predictive capability. The MEDS score demonstrated the largest AUC of the studied scoring systems for the outcome of mortality, although the CIs on point estimates of the AUC of the REMS and CURB-65 scores all overlap.

  4. Prostate ultrasound imaging: evaluation of a two-step scoring system in the diagnosis of prostate cancer.

    Science.gov (United States)

    Gao, Yong; Liao, Xin-Hong; Ma, Yan; Lu, Lu; Wei, Li-Yan; Yan, Xue

    2017-12-01

    This study aims to investigate the feasibility and performance of a two-step scoring system of ultrasound imaging in the diagnosis of prostate cancer. 75 patients with 888 consecutive histopathologically verified lesions were included in this study. Step 1, an initial 5-point scoring system was developed based on conventional transrectal ultrasound (TRUS). Step 2, a final scoring system was evaluated according to contrast-enhanced transrectal ultrasound (CE-TRUS). Each lesion was evaluated using the two-step scoring system (step 1 + step 2) and compared with only using conventional TRUS (step 1). 888 lesions were histologically verified: 315 of them were prostate cancer from 46 patients and 573 were benign prostatic hypertrophy (BPH) from 29 patients. According to the two-step scoring system, 284 lesions were upgraded and 130 lesions were downgraded from step 1 to step 2 (this means using step 2 to assess the results by step 1). However, 96 cases were improperly upgraded after step 2 and 48 malignant lesions were still missed after step 2 as score-1. For the two-step scoring system, the sensitivity, specificity, and accuracy were 84.7%, 83.2%, and 83.7%, respectively, versus 22.8%, 96.6%, and 70.4%, respectively, for conventional TRUS. The area under the ROC curve (AUC) for lesion diagnosis was 0.799-0.952 for the two-step scoring system, versus 0.479-0.712 for conventional TRUS. The difference in the diagnostic accuracy of the two-step scoring system and conventional TRUS was statistically significant (Pstep scoring system was straightforward to use and achieved a considerably accurate diagnostic performance for prostate cancer. The application of the two-step scoring system for prostate cancer is promising.

  5. Assessment of three risk evaluation systems for patients aged ≥70 in East China: performance of SinoSCORE, EuroSCORE II and the STS risk evaluation system.

    Science.gov (United States)

    Shan, Lingtong; Ge, Wen; Pu, Yiwei; Cheng, Hong; Cang, Zhengqiang; Zhang, Xing; Li, Qifan; Xu, Anyang; Wang, Qi; Gu, Chang; Zhang, Yangyang

    2018-01-01

    To assess and compare the predictive ability of three risk evaluation systems (SinoSCORE, EuroSCORE II and the STS risk evaluation system) in patients aged ≥70, and who underwent coronary artery bypass grafting (CABG) in East China. Three risk evaluation systems were applied to 1,946 consecutive patients who underwent isolated CABG from January 2004 to September 2016 in two hospitals. Patients were divided into two subsets according to their age: elderly group (age ≥70) with a younger group (age evaluation system were 0.78(0.64)%, 1.43(1.14)% and 0.78(0.77)%, respectively. SinoSCORE achieved the best discrimination (the area under the receiver operating characteristic curve (AUC) = 0.829), followed by the STS risk evaluation system (AUC = 0.790) and EuroSCORE II (AUC = 0.769) in the entire cohort. In the elderly group, the observed mortality rate was 4.82% while it was 1.38% in the younger group. SinoSCORE (AUC = .829) also achieved the best discrimination in the elderly group, followed by the STS risk evaluation system (AUC = .730) and EuroSCORE II (AUC = 0.640) while all three risk evaluation systems all had good performances in the younger group. SinoSCORE, EuroSCORE II and the STS risk evaluation system all achieved positive calibrations in the entire cohort and subsets. The performance of the three risk evaluation systems was not ideal in the entire cohort. In the elderly group, SinoSCORE appeared to achieve better predictive efficiency than EuroSCORE II and the STS risk evaluation system.

  6. A clinical severity scoring system for visceral leishmaniasis in immunocompetent patients in South Sudan.

    Directory of Open Access Journals (Sweden)

    Suzette S Kämink

    2017-10-01

    Full Text Available South Sudan is one of the most endemic countries for visceral leishmaniasis (VL, and is frequently affected by large epidemics. In resource-limited settings, clinicians require a simple clinical tool to identify VL patients who are at increased risk of dying, and who need specialised treatment with liposomal amphotericin B and other supportive care. The aim of this study was to develop and validate a clinical severity scoring system based on risk factors for death in VL patients in South Sudan.A retrospective analysis was conducted of data from a cohort of 6,633 VL patients who were treated in the Médecins Sans Frontières (MSF hospital in Lankien between July 2013 and June 2015. Risk factors for death during treatment were identified using multivariable logistic regression models, and the regression coefficients were used to develop a severity scoring system. Sensitivity and specificity of score cut-offs were assessed by receiver operating characteristic (ROC analysis.In multivariable models, risk factors for death in adult VL patients were: anaemia (odds ratio (OR 4.46 (95% CI 1.58-12.6 for Hb <6g/dL compared with ≥9g/dL, nutritional status (OR 4.84 (2.09-11.2 for BMI <13 kg/m2 compared with ≥16 kg/m2, weakness (OR 4.20 (1.82-9.73 for collapsed compared with normal weakness, jaundice (OR 3.41 (1.17-9.95, and oedema/ascites (OR 4.86 (1.67-14.1. For children and adolescents the risk factors were: age (OR 10.7 (6.3-18.3 for age <2 years compared with 6-18 years, anaemia (OR 7.76 (4.15-14.5 for Hb <6g/dL compared with ≥9g/dL, weakness (OR 3.13 (22.8-105.2 for collapsed compared with normal weakness, and jaundice (OR 12.8 (4.06-40.2. Severity scoring predictive ability was 74.4% in adults and 83.4% in children and adolescents.Our evidenced-based severity scoring system demonstrated sufficient predictive ability to be operationalised as a clinical tool for rational allocation of treatment to VL patients at MSF centres in South Sudan.

  7. Prostate Cancer Patients' Understanding of the Gleason Scoring System: Implications for Shared Decision-Making.

    Science.gov (United States)

    Tagai, Erin K; Miller, Suzanne M; Kutikov, Alexander; Diefenbach, Michael A; Gor, Ronak A; Al-Saleem, Tahseen; Chen, David Y T; Fleszar, Sara; Roy, Gem

    2018-01-15

    The Gleason scoring system is a key component of a prostate cancer diagnosis, since it indicates disease aggressiveness. It also serves as a risk communication tool that facilitates shared treatment decision-making. However, the system is highly complex and therefore difficult to communicate: factors which have been shown to undermine well-informed and high-quality shared treatment decision-making. To systematically explore prostate cancer patients' understanding of the Gleason scoring system (GSS), we assessed knowledge and perceived importance among men who had completed treatment (N = 50). Patients were administered a survey that assessed patient knowledge and patients' perceived importance of the GSS, as well as demographics, medical factors (e.g., Gleason score at diagnosis), and health literacy. Bivariate analyses were conducted to identify associations with patient knowledge and perceived importance of the GSS. The sample was generally well-educated (48% with a bachelor's degree or higher) and health literate (M = 12.9, SD = 2.2, range = 3-15). Despite this, patient knowledge of the GSS was low (M = 1.8, SD = 1.4, range = 1-4). Patients' understanding of the importance of the GSS was moderate (M = 2.8, SD = 1.0, range = 0-4) and was positively associated with GSS knowledge (p decision-making. Future studies are needed to explore the potential utility of a simplified Gleason grading system and improved patient-provider communication.

  8. Acute Radiation Syndrome Severity Score System in Mouse Total-Body Irradiation Model.

    Science.gov (United States)

    Ossetrova, Natalia I; Ney, Patrick H; Condliffe, Donald P; Krasnopolsky, Katya; Hieber, Kevin P

    2016-08-01

    Radiation accidents or terrorist attacks can result in serious consequences for the civilian population and for military personnel responding to such emergencies. The early medical management situation requires quantitative indications for early initiation of cytokine therapy in individuals exposed to life-threatening radiation doses and effective triage tools for first responders in mass-casualty radiological incidents. Previously established animal (Mus musculus, Macaca mulatta) total-body irradiation (γ-exposure) models have evaluated a panel of radiation-responsive proteins that, together with peripheral blood cell counts, create a multiparametic dose-predictive algorithm with a threshold for detection of ~1 Gy from 1 to 7 d after exposure as well as demonstrate the acute radiation syndrome severity score systems created similar to the Medical Treatment Protocols for Radiation Accident Victims developed by Fliedner and colleagues. The authors present a further demonstration of the acute radiation sickness severity score system in a mouse (CD2F1, males) TBI model (1-14 Gy, Co γ-rays at 0.6 Gy min) based on multiple biodosimetric endpoints. This includes the acute radiation sickness severity Observational Grading System, survival rate, weight changes, temperature, peripheral blood cell counts and radiation-responsive protein expression profile: Flt-3 ligand, interleukin 6, granulocyte-colony stimulating factor, thrombopoietin, erythropoietin, and serum amyloid A. Results show that use of the multiple-parameter severity score system facilitates identification of animals requiring enhanced monitoring after irradiation and that proteomics are a complementary approach to conventional biodosimetry for early assessment of radiation exposure, enhancing accuracy and discrimination index for acute radiation sickness response categories and early prediction of outcome.

  9. Clinical performance of two visual scoring systems in detecting and assessing activity status of occlusal caries in primary teeth

    DEFF Research Database (Denmark)

    Braga, M M; Ekstrand, K R; Martignon, S

    2010-01-01

    This study aimed to compare the clinical performance of two sets of visual scoring criteria for detecting caries severity and assessing caries activity status in occlusal surfaces. Two visual scoring systems--the Nyvad criteria (NY) and the ICDAS-II including an adjunct system for lesion activity...

  10. Two-step calibration method for multi-algorithm score-based face recognition systems by minimizing discrimination loss

    NARCIS (Netherlands)

    Susyanto, N.; Veldhuis, R.N.J.; Spreeuwers, L.J.; Klaassen, C.A.J.; Fierrez, J.; Li, S.Z.; Ross, A.; Veldhuis, R.; Alonso-Fernandez, F.; Bigun, J.

    2016-01-01

    We propose a new method for combining multi-algorithm score-based face recognition systems, which we call the two-step calibration method. Typically, algorithms for face recognition systems produce dependent scores. The two-step method is based on parametric copulas to handle this dependence. Its

  11. The Zhongshan score: a novel and simple anatomic classification system to predict perioperative outcomes of nephron-sparing surgery.

    Science.gov (United States)

    Zhou, Lin; Guo, Jianming; Wang, Hang; Wang, Guomin

    2015-02-01

    In the zero ischemia era of nephron-sparing surgery (NSS), a new anatomic classification system (ACS) is needed to adjust to these new surgical techniques. We devised a novel and simple ACS, and compared it with the RENAL and PADUA scores to predict the risk of NSS outcomes. We retrospectively evaluated 789 patients who underwent NSS with available imaging between January 2007 and July 2014. Demographic and clinical data were assessed. The Zhongshan (ZS) score consisted of three parameters. RENAL, PADUA, and ZS scores are divided into three groups, that is, high, moderate, and low scores. For operative time (OT), significant differences were seen between any two groups of ZS score and PADUA score (all P RENAL showed no significant difference between moderate and high complexity in OT, WIT, estimated blood loss, and increase in SCr. Compared with patients with a low score of ZS, those with a high or moderate score had 8.1-fold or 3.3-fold higher risk of surgical complications, respectively (all P RENAL score, patients with a high or moderate score had 5.7-fold or 1.9-fold higher risk of surgical complications, respectively (all P RENAL and PADUA scores. ZS score could be used to reflect the surgical complexity and predict the risk of surgical complications in patients undergoing NSS.

  12. Comparison of the balance accelerometer measure and balance error scoring system in adolescent concussions in sports.

    Science.gov (United States)

    Furman, Gabriel R; Lin, Chia-Cheng; Bellanca, Jennica L; Marchetti, Gregory F; Collins, Michael W; Whitney, Susan L

    2013-06-01

    High-technology methods demonstrate that balance problems may persist up to 30 days after a concussion, whereas with low-technology methods such as the Balance Error Scoring System (BESS), performance becomes normal after only 3 days based on previously published studies in collegiate and high school athletes. To compare the National Institutes of Health's Balance Accelerometer Measure (BAM) with the BESS regarding the ability to detect differences in postural sway between adolescents with sports concussions and age-matched controls. Cohort study (diagnosis); Level of evidence, 2. Forty-three patients with concussions and 27 control participants were tested with the standard BAM protocol, while sway was quantified using the normalized path length (mG/s) of pelvic accelerations in the anterior-posterior direction. The BESS was scored by experts using video recordings. The BAM was not able to discriminate between healthy and concussed adolescents, whereas the BESS, especially the tandem stance conditions, was good at discriminating between healthy and concussed adolescents. A total BESS score of 21 or more errors optimally identified patients in the acute concussion group versus healthy participants at 60% sensitivity and 82% specificity. The BAM is not as effective as the BESS in identifying abnormal postural control in adolescents with sports concussions. The BESS, a simple and economical method of assessing postural control, was effective in discriminating between young adults with acute concussions and young healthy people, suggesting that the test has value in the assessment of acute concussions.

  13. High-dimensional analysis of the aging immune system: verification of age-associated differences in immune signaling responses in healthy donors.

    Science.gov (United States)

    Longo, Diane M; Louie, Brent; Ptacek, Jason; Friedland, Greg; Evensen, Erik; Putta, Santosh; Atallah, Michelle; Spellmeyer, David; Wang, Ena; Pos, Zoltan; Marincola, Francesco M; Schaeffer, Andrea; Lukac, Suzanne; Railkar, Radha; Beals, Chan R; Cesano, Alessandra; Carayannopoulos, Leonidas N; Hawtin, Rachael E

    2014-06-21

    Single-cell network profiling (SCNP) is a multiparametric flow cytometry-based approach that simultaneously measures evoked signaling in multiple cell subsets. Previously, using the SCNP approach, age-associated immune signaling responses were identified in a cohort of 60 healthy donors. In the current study, a high-dimensional analysis of intracellular signaling was performed by measuring 24 signaling nodes in 7 distinct immune cell subsets within PBMCs in an independent cohort of 174 healthy donors [144 elderly (>65 yrs); 30 young (25-40 yrs)]. Associations between age and 9 immune signaling responses identified in the previously published 60 donor cohort were confirmed in the current study. Furthermore, within the current study cohort, 48 additional immune signaling responses differed significantly between young and elderly donors. These associations spanned all profiled modulators and immune cell subsets. These results demonstrate that SCNP, a systems-based approach, can capture the complexity of the cellular mechanisms underlying immunological aging. Further, the confirmation of age associations in an independent donor cohort supports the use of SCNP as a tool for identifying reproducible predictive biomarkers in areas such as vaccine response and response to cancer immunotherapies.

  14. Sensitivity and specificity of a new scoring system for diabetic macular oedema detection using a confocal laser imaging system

    Science.gov (United States)

    Tong, L; Ang, A; Vernon, S; Zambarakji, H; Bhan, A; Sung, V; Page, S

    2001-01-01

    AIM—To assess the use of the Heidelberg retina tomograph (HRT) in screening for sight threatening diabetic macular oedema in a hospital diabetic clinic, using a new subjective analysis system (SCORE).
METHODS—200 eyes of 100 consecutive diabetic patients attending a diabetologist's clinic were studied, all eyes had an acuity of 6/9 or better. All patients underwent clinical examination by an ophthalmologist. Using the HRT, one good scan was obtained for each eye centred on the fovea. A System for Classification and Ordering of Retinal Edema (SCORE) was developed using subjective assessment of the colour map and the reflectivity image. The interobserver agreement of using this method to detect macular oedema was assessed by two observers (ophthalmic trainees) who were familiarised with SCORE by studying standard pictures of eyes not in the study. All scans were graded from 0-6 and test positive cases were defined as having a SCORE value of 0-2. The sensitivity of SCORE was assessed by pooling the data with an additional 88 scans of 88 eyes in order to reduce the confidence interval of the index.
RESULTS—12 eyes in eight out of the 100 patients had macular oedema clinically. Three scans in three patients could not be analysed because of poor scan quality. In the additional group of scans 76 out of 88 eyes had macular oedema clinically. The scoring system had a specificity of 99% (95% CI 96-100) and sensitivity of 67% (95% CI 57-76). The predictive value of a negative test was 87% (95% CI 82-99), and that of a positive test was 95% (95% CI 86-99). The mean difference of the SCORE value between two observers was -0.2 (95% CI -0.5 to +0.07).
CONCLUSIONS—These data suggest that SCORE is potentially useful for detecting diabetic macular oedema in hospital diabetic patients.

 PMID:11133709

  15. Multimodal Biometric System- Fusion Of Face And Fingerprint Biometrics At Match Score Fusion Level

    Directory of Open Access Journals (Sweden)

    Grace Wangari Mwaura

    2017-04-01

    Full Text Available Biometrics has developed to be one of the most relevant technologies used in Information Technology IT security. Unimodal biometric systems have a variety of problems which decreases the performance and accuracy of these system. One way to overcome the limitations of the unimodal biometric systems is through fusion to form a multimodal biometric system. Generally biometric fusion is defined as the use of multiple types of biometric data or ways of processing the data to improve the performance of biometric systems. This paper proposes to develop a model for fusion of the face and fingerprint biometric at the match score fusion level. The face and fingerprint unimodal in the proposed model are built using scale invariant feature transform SIFT algorithm and the hamming distance to measure the distance between key points. To evaluate the performance of the multimodal system the FAR and FRR of the multimodal are compared along those of the individual unimodal systems. It has been established that the multimodal has a higher accuracy of 92.5 compared to the face unimodal system at 90 while the fingerprint unimodal system is at 82.5.

  16. Severity score system for progressive myelopathy: development and validation of a new clinical scale

    Directory of Open Access Journals (Sweden)

    R.M. Castilhos

    2012-07-01

    Full Text Available Progressive myelopathies can be secondary to inborn errors of metabolism (IEM such as mucopolysaccharidosis, mucolipidosis, and adrenomyeloneuropathy. The available scale, Japanese Orthopaedic Association (JOA score, was validated only for degenerative vertebral diseases. Our objective is to propose and validate a new scale addressing progressive myelopathies and to present validating data for JOA in these diseases. A new scale, Severity Score System for Progressive Myelopathy (SSPROM, covering motor disability, sphincter dysfunction, spasticity, and sensory losses. Inter- and intra-rater reliabilities were measured. External validation was tested by applying JOA, the Expanded Disability Status Scale (EDSS, the Barthel index, and the Osame Motor Disability Score. Thirty-eight patients, 17 with adrenomyeloneuropathy, 3 with mucopolysaccharidosis I, 3 with mucopolysaccharidosis IV, 2 with mucopolysaccharidosis VI, 2 with mucolipidosis, and 11 with human T-cell lymphotropic virus type-1 (HTLV-1-associated myelopathy participated in the study. The mean ± SD SSPROM and JOA scores were 74.6 ± 11.4 and 12.4 ± 2.3, respectively. Construct validity for SSPROM (JOA: r = 0.84, P < 0.0001; EDSS: r = -0.83, P < 0.0001; Barthel: r = 0.56, P < 0.002; Osame: r = -0.94, P < 0.0001 and reliability (intra-rater: r = 0.83, P < 0.0001; inter-rater: r = 0.94, P < 0.0001 were demonstrated. The metric properties of JOA were similar to those found in SSPROM. Several clinimetric requirements were met for both SSPROM and JOA scales. Since SSPROM has a wider range, it should be useful for follow-up studies on IEM myelopathies.

  17. The prognostic value of the systemic inflammatory score in patients with unresectable metastatic colorectal cancer.

    Science.gov (United States)

    Shibutani, Masatsune; Maeda, Kiyoshi; Nagahara, Hisashi; Fukuoka, Tatsunari; Matsutani, Shinji; Kimura, Kenjiro; Amano, Ryosuke; Hirakawa, Kosei; Ohira, Masaichi

    2018-07-01

    Inflammation has been widely recognized as a contributor to cancer progression and several inflammatory markers have been reported as associated with the clinical outcomes in patients with various types of cancer. Recently, a novel inflammatory marker, the systemic inflammatory score (SIS), which is based on a combination of the lymphocyte-to-monocyte ratio (LMR) and the serum albumin concentration has been reported as a useful prognostic marker. The aim of the present study was to assess the prognostic value of the SIS in patients with unresectable metastatic colorectal cancer (mCRC). The retrospective cohort study included 160 patients who underwent combination chemotherapy for unresectable mCRC between January 2008 and December 2016. The SIS was used to classify the patients into three groups based on their LMR and the serum albumin concentration. Patients with high-LMR and high serum albumin level were given a score of 0; patients with low-LMR or low serum albumin level were given a score of 1; patients with low-LMR and low serum albumin level were given a score of 2. There were significant differences in the overall survival among the three SIS groups and the SIS was an independent prognostic factor for the overall survival. Although the SIS was significantly associated with the overall survival rate even when using the original cut-off values, the SIS according to the new cut-off values had a more accurate prognostic value. The present study determined that the SIS was a useful biomarker for predicting the survival outcomes in patients with unresectable mCRC, although the optimum cut-off value of the SIS according to the patients' background needs to be examined in further studies.

  18. Development and Reliability of the OMERACT Thumb Base Osteoarthritis Magnetic Resonance Imaging Scoring System

    DEFF Research Database (Denmark)

    Kroon, Féline P B; Conaghan, Philip G; Foltz, Violaine

    2017-01-01

    : The TOMS assessed the first carpometacarpal (CMC-1) and scaphotrapeziotrapezoid (STT) joints for synovitis, subchondral bone defects (including erosions, cysts, and bone attrition), osteophytes, cartilage, and bone marrow lesions on a 0-3 scale (normal to severe). Subluxation was evaluated only in the CMC......, with better performance for subchondral bone defects, subluxation, and bone marrow lesions. CONCLUSION: A thumb base OA MRI scoring system has been developed. The OMERACT TOMS demonstrated good intrareader and interreader reliability. Longitudinal studies are warranted to investigate reliability of change...

  19. Late effects of normal tissues (lent) scoring system: the soma scale

    International Nuclear Information System (INIS)

    Mornex, F.; Pavy, J.J.; Denekamp, J.

    1997-01-01

    Radiation tolerance of normal tissues remains the limiting factor for delivering tumoricidal dose. The late toxicity of normal tissues is the most critical element of an irradiation: somatic, functional and structural alterations occur during the actual treatment itself, but late effects manifest months to years after acute effects heal, and may progress with time. The optimal therapeutic ratio ultimately requires not only complete tumor clearance, but also minimal residual injury to surrounding vital normal tissues. The disparity between the intensity of acute and late effects and the inability to predict the eventual manifestation of late normal tissue injury has made radiation oncologists recognize the importance of careful patient follow-up. There is so far no uniform toxicity scoring system to compare several clinical studies in the absence of a 'common toxicity language'. This justifies the need to establish a precise evaluation system for the analysis of late effects of radiation on normal tissues. The SOMA/LENT scoring system results from an international collaboration. European Organization Treatment of Cancer (EORTC) and Radiation Therapy Oncology Group (RTOG) have created subcommittees with the aim of addressing the question of standardized toxic effects criteria. This effort appeared as a necessity to standardize and improve the data recording, to then describe and evaluate uniform toxicity at regular time intervals. The current proposed scale is not yet validated, and should be used cautiously. (authors)

  20. AN IMPLEMENTATION OF VIBRATION-BASED AUTOMATIC SCORE-KEEPING SYSTEM FOR TABLE TENNIS GAME

    Directory of Open Access Journals (Sweden)

    Erdem YAVUZ

    2014-01-01

    Full Text Available In sport tournaments human factor plays an important role to evaluate the game. Table tennis is an example of this kind of sports. In order to avoid erroneous human decisions and to enhance referees’ decisions an automatic score-keeping system for table tennis game is designed and implemented with low cost vibration sensors attached underside of the tennis table. The purpose of using vibration sensors is to detect ball colliding with the surface. An additional vibration sensor is also used to detect ball touching the net, determining let state in the game. Petri net scheme is used to model the operation of the system, making it easy to visualize its operation. We believe that the proposed system will contribute much to better evaluate the various phases of table tennis games and to aid the referees to make better decisions.

  1. Influence of Coherent Tunneling and Incoherent Hopping on the Charge Transfer Mechanism in Linear Donor-Bridge-Acceptor Systems.

    Science.gov (United States)

    Li, Guangqi; Govind, Niranjan; Ratner, Mark A; Cramer, Christopher J; Gagliardi, Laura

    2015-12-17

    The mechanism of charge transfer has been observed to change from tunneling to hopping with increasing numbers of DNA base pairs in polynucleotides and with the length of molecular wires. The aim of this paper is to investigate this transition by examining the population dynamics using a tight-binding Hamiltonian with model parameters to describe a linear donor-bridge-acceptor (D-B-A) system. The model includes a primary vibration and an electron-vibration coupling at each site. A further coupling of the primary vibration with a secondary phonon bath allows the system to dissipate energy to the environment and reach a steady state. We apply the quantum master equation (QME) approach, based on second-order perturbation theory in a quantum dissipative system, to examine the dynamical processes involved in charge-transfer and follow the population transfer rate at the acceptor, ka, to shed light on the transition from tunneling to hopping. With a small tunneling parameter, V, the on-site population tends to localize and form polarons, and the hopping mechanism dominates the transfer process. With increasing V, the population tends to be delocalized and the tunneling mechanism dominates. The competition between incoherent hopping and coherent tunneling governs the mechanism of charge transfer. By varying V and the total number of sites, we also examine the onset of the transition from tunneling to hopping with increasing length.

  2. Reliability of ultrasound grading traditional score and new global OMERACT-EULAR score system (GLOESS): results from an inter- and intra-reading exercise by rheumatologists.

    Science.gov (United States)

    Ventura-Ríos, Lucio; Hernández-Díaz, Cristina; Ferrusquia-Toríz, Diana; Cruz-Arenas, Esteban; Rodríguez-Henríquez, Pedro; Alvarez Del Castillo, Ana Laura; Campaña-Parra, Alfredo; Canul, Efrén; Guerrero Yeo, Gerardo; Mendoza-Ruiz, Juan Jorge; Pérez Cristóbal, Mario; Sicsik, Sandra; Silva Luna, Karina

    2017-12-01

    This study aims to test the reliability of ultrasound to graduate synovitis in static and video images, evaluating separately grayscale and power Doppler (PD), and combined. Thirteen trained rheumatologist ultrasonographers participated in two separate rounds reading 42 images, 15 static and 27 videos, of the 7-joint count [wrist, 2nd and 3rd metacarpophalangeal (MCP), 2nd and 3rd interphalangeal (IPP), 2nd and 5th metatarsophalangeal (MTP) joints]. The images were from six patients with rheumatoid arthritis, performed by one ultrasonographer. Synovitis definition was according to OMERACT. Scoring system in grayscale, PD separately, and combined (GLOESS-Global OMERACT-EULAR Score System) were reviewed before exercise. Reliability intra- and inter-reading was calculated with Cohen's kappa weighted, according to Landis and Koch. Kappa values for inter-reading were good to excellent. The minor kappa was for GLOESS in static images, and the highest was for the same scoring in videos (k 0.59 and 0.85, respectively). Excellent values were obtained for static PD in 5th MTP joint and for PD video in 2nd MTP joint. Results for GLOESS in general were good to moderate. Poor agreement was observed in 3rd MCP and 3rd IPP in all kinds of images. Intra-reading agreement were greater in grayscale and GLOESS in static images than in videos (k 0.86 vs. 0.77 and k 0.86 vs. 0.71, respectively), but PD was greater in videos than in static images (k 1.0 vs. 0.79). The reliability of the synovitis scoring through static images and videos is in general good to moderate when using grayscale and PD separately or combined.

  3. Validation of systems biology derived molecular markers of renal donor organ status associated with long term allograft function.

    Science.gov (United States)

    Perco, Paul; Heinzel, Andreas; Leierer, Johannes; Schneeberger, Stefan; Bösmüller, Claudia; Oberhuber, Rupert; Wagner, Silvia; Engler, Franziska; Mayer, Gert

    2018-05-03

    Donor organ quality affects long term outcome after renal transplantation. A variety of prognostic molecular markers is available, yet their validity often remains undetermined. A network-based molecular model reflecting donor kidney status based on transcriptomics data and molecular features reported in scientific literature to be associated with chronic allograft nephropathy was created. Significantly enriched biological processes were identified and representative markers were selected. An independent kidney pre-implantation transcriptomics dataset of 76 organs was used to predict estimated glomerular filtration rate (eGFR) values twelve months after transplantation using available clinical data and marker expression values. The best-performing regression model solely based on the clinical parameters donor age, donor gender, and recipient gender explained 17% of variance in post-transplant eGFR values. The five molecular markers EGF, CD2BP2, RALBP1, SF3B1, and DDX19B representing key molecular processes of the constructed renal donor organ status molecular model in addition to the clinical parameters significantly improved model performance (p-value = 0.0007) explaining around 33% of the variability of eGFR values twelve months after transplantation. Collectively, molecular markers reflecting donor organ status significantly add to prediction of post-transplant renal function when added to the clinical parameters donor age and gender.

  4. [Severity of disease scoring systems and mortality after non-cardiac surgery].

    Science.gov (United States)

    Reis, Pedro Videira; Sousa, Gabriela; Lopes, Ana Martins; Costa, Ana Vera; Santos, Alice; Abelha, Fernando José

    2018-04-05

    Mortality after surgery is frequent and severity of disease scoring systems are used for prediction. Our aim was to evaluate predictors for mortality after non-cardiac surgery. Adult patients admitted at our surgical intensive care unit between January 2006 and July 2013 was included. Univariate analysis was carried using Mann-Whitney, Chi-square or Fisher's exact test. Logistic regression was performed to assess independent factors with calculation of odds ratio and 95% confidence interval (95% CI). 4398 patients were included. Mortality was 1.4% in surgical intensive care unit and 7.4% during hospital stay. Independent predictors of mortality in surgical intensive care unit were APACHE II (OR=1.24); emergent surgery (OR=4.10), serum sodium (OR=1.06) and FiO 2 at admission (OR=14.31). Serum bicarbonate at admission (OR=0.89) was considered a protective factor. Independent predictors of hospital mortality were age (OR=1.02), APACHE II (OR=1.09), emergency surgery (OR=1.82), high-risk surgery (OR=1.61), FiO 2 at admission (OR=1.02), postoperative acute renal failure (OR=1.96), heart rate (OR=1.01) and serum sodium (OR=1.04). Dying patients had higher scores in severity of disease scoring systems and longer surgical intensive care unit stay. Some factors influenced both surgical intensive care unit and hospital mortality. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  5. Dynamical System Modeling to Simulate Donor T Cell Response to Whole Exome Sequencing-Derived Recipient Peptides Demonstrates Different Alloreactivity Potential in HLA-Matched and -Mismatched Donor-Recipient Pairs.

    Science.gov (United States)

    Abdul Razzaq, Badar; Scalora, Allison; Koparde, Vishal N; Meier, Jeremy; Mahmood, Musa; Salman, Salman; Jameson-Lee, Max; Serrano, Myrna G; Sheth, Nihar; Voelkner, Mark; Kobulnicky, David J; Roberts, Catherine H; Ferreira-Gonzalez, Andrea; Manjili, Masoud H; Buck, Gregory A; Neale, Michael C; Toor, Amir A

    2016-05-01

    Immune reconstitution kinetics and subsequent clinical outcomes in HLA-matched recipients of allogeneic stem cell transplantation (SCT) are variable and difficult to predict. Considering SCT as a dynamical system may allow sequence differences across the exomes of the transplant donors and recipients to be used to simulate an alloreactive T cell response, which may allow better clinical outcome prediction. To accomplish this, whole exome sequencing was performed on 34 HLA-matched SCT donor-recipient pairs (DRPs) and the nucleotide sequence differences translated to peptides. The binding affinity of the peptides to the relevant HLA in each DRP was determined. The resulting array of peptide-HLA binding affinity values in each patient was considered as an operator modifying a hypothetical T cell repertoire vector, in which each T cell clone proliferates in accordance with the logistic equation of growth. Using an iterating system of matrices, each simulated T cell clone's growth was calculated with the steady-state population being proportional to the magnitude of the binding affinity of the driving HLA-peptide complex. Incorporating competition between T cell clones responding to different HLA-peptide complexes reproduces a number of features of clinically observed T cell clonal repertoire in the simulated repertoire, including sigmoidal growth kinetics of individual T cell clones and overall repertoire, Power Law clonal frequency distribution, increase in repertoire complexity over time with increasing clonal diversity, and alteration of clonal dominance when a different antigen array is encountered, such as in SCT. The simulated, alloreactive T cell repertoire was markedly different in HLA-matched DRPs. The patterns were differentiated by rate of growth and steady-state magnitude of the simulated T cell repertoire and demonstrate a possible correlation with survival. In conclusion, exome wide sequence differences in DRPs may allow simulation of donor alloreactive T

  6. Validation of use of subsets of teeth when applying the total mouth periodontal score (TMPS) system in dogs.

    Science.gov (United States)

    Harvey, Colin E; Laster, Larry; Shofer, Frances S

    2012-01-01

    A total mouth periodontal score (TMPS) system in dogs has been described previously. Use of buccal and palatal/lingual surfaces of all teeth requires observation and recording of 120 gingivitis scores and 120 periodontitis scores. Although the result is a reliable, repeatable assessment of the extent of periodontal disease in the mouth, observing and recording 240 data points is time-consuming. Using data from a previously reported study of periodontal disease in dogs, correlation analysis was used to determine whether use of any of seven different subsets of teeth can generate TMPS subset gingivitis and periodontitis scores that are highly correlated with TMPS all-site, all-teeth scores. Overall, gingivitis scores were less highly correlated than periodontitis scores. The minimal tooth set with a significant intra-class correlation (> or = 0.9 of means of right and left sides) for both gingivitis scores and attachment loss measurements consisted of the buccal surface of the maxillary third incisor canine, third premolar fourth premolar; and first molar teeth; and, the mandibular canine, third premolar, fourth premolar and first molar teeth on one side (9 teeth, 15 root sites). Use of this subset of teeth, which reduces the number of data points per dog from 240 to 30 for gingivitis and periodontitis at each scoring episode, is recommended when calculating the gingivitis and periodontitis scores using the TMPS system.

  7. A critical appraisal of radiographic scoring systems for assessment of juvenile idiopathic arthritis

    International Nuclear Information System (INIS)

    Doria, Andrea S.; Babyn, Paul S.; Feldman, Brian

    2006-01-01

    Assessing structural damage to joints over time is essential for evaluating the effectiveness of therapeutic interventions for patients with inflammatory arthritis. Although radiography is able to quantify joint damage, the changes found with conventional radiography early in the disease course are nonspecific, and late radiographic changes are often irreversible. Although many clinical trials on drug development for children still use radiographic scales as endpoints for the study, more specific therapies have been developed for juvenile idiopathic arthritis (JIA) that would enable imaging to ''fine-tune'' patients to placement into specific treatment algorithms. As a result, new imaging scales to identify early abnormalities are clearly needed. Many pediatric rheumatology centers around the world persistently apply adult-designed radiographic scoring systems to evaluate the progression of JIA. Few pediatric-targeted radiographic scales are available for assessment of progression of JIA in growing joints, and the clinimetric and psychometric properties of such scales have been poorly investigated. We present a critique to the evaluative, discriminative, and predictive roles of the van der Heijde modification of Sharp's radiographic method, a scale originally designed to assess damage to joints of adults with rheumatoid arthritis, when it is applied to a pediatric population. We discuss the advantages and drawbacks of this radiographic scoring system for assessing growing joints and the ability of MRI to overcome inadequacies of conventional radiography. (orig.)

  8. Scoring system predictive of survival for patients undergoing stereotactic body radiation therapy for liver tumors

    Directory of Open Access Journals (Sweden)

    Kress Marie-Adele S

    2012-09-01

    Full Text Available Abstract Background Stereotactic body radiation therapy (SBRT is an emerging treatment option for liver tumors. This study evaluated outcomes after SBRT to identify prognostic variables and to develop a novel scoring system predictive of survival. Methods The medical records of 52 patients with a total of 85 liver lesions treated with SBRT from 2003 to 2010 were retrospectively reviewed. Twenty-four patients had 1 lesion; 27 had 2 or more. Thirteen lesions were primary tumors; 72 were metastases. Fiducials were placed in all patients prior to SBRT. The median prescribed dose was 30 Gy (range, 16 – 50 Gy in a median of 3 fractions (range, 1–5. Results With median follow-up of 11.3 months, median overall survival (OS was 12.5 months, and 1 year OS was 50.8%. In 42 patients with radiographic follow up, 1 year local control was 74.8%. On univariate analysis, number of lesions (p = 0.0243 and active extralesional disease (p  Conclusions SBRT offers a safe and feasible treatment option for liver tumors. A prognostic scoring system based on the number of liver lesions, activity of extralesional disease, and KPS predicts survival following SBRT and can be used as a guide for prospective validation and ultimately for treatment decision-making.

  9. Development and validation of a prognostic scoring system for patients with chronic myelomonocytic leukemia.

    Science.gov (United States)

    Such, Esperanza; Germing, Ulrich; Malcovati, Luca; Cervera, José; Kuendgen, Andrea; Della Porta, Matteo G; Nomdedeu, Benet; Arenillas, Leonor; Luño, Elisa; Xicoy, Blanca; Amigo, Mari L; Valcarcel, David; Nachtkamp, Kathrin; Ambaglio, Ilaria; Hildebrandt, Barbara; Lorenzo, Ignacio; Cazzola, Mario; Sanz, Guillermo

    2013-04-11

    The natural course of chronic myelomonocytic leukemia (CMML) is highly variable but a widely accepted prognostic scoring system for patients with CMML is not available. The main aim of this study was to develop a new CMML-specific prognostic scoring system (CPSS) in a large series of 558 patients with CMML (training cohort, Spanish Group of Myelodysplastic Syndromes) and to validate it in an independent series of 274 patients (validation cohort, Heinrich Heine University Hospital, Düsseldorf, Germany, and San Matteo Hospital, Pavia, Italy). The most relevant variables for overall survival (OS) and evolution to acute myeloblastic leukemia (AML) were FAB and WHO CMML subtypes, CMML-specific cytogenetic risk classification, and red blood cell (RBC) transfusion dependency. CPSS was able to segregate patients into 4 clearly different risk groups for OS (P < .001) and risk of AML evolution (P < .001) and its predictive capability was confirmed in the validation cohort. An alternative CPSS with hemoglobin instead of RBC transfusion dependency offered almost identical prognostic capability. This study confirms the prognostic impact of FAB and WHO subtypes, recognizes the importance of RBC transfusion dependency and cytogenetics, and offers a simple and powerful CPSS for accurately assessing prognosis and planning therapy in patients with CMML.

  10. A wireless-sensor scoring and training system for combative sports

    Science.gov (United States)

    Partridge, Kane; Hayes, Jason P.; James, Daniel A.; Hill, Craig; Gin, Gareth; Hahn, Allan

    2005-02-01

    Although historically among the most popular of sports, today, combative sports are often viewed as an expression of our savage past. Of primary concern are the long term effects of participating in these sports on the health of participants. The scoring of such sports has also been the subject of much debate, with a panel of judges making decisions about very quick events involving large sums of prize money. This paper describes an electronic system for use primarily in the sport of boxing, though it is suitable for martial arts such as karate and taekwondo. The technology is based on a previously described sensor platform and integrates a network of sensors on the athlete"s head, body and hands. Using a Bluetooth network, physical contacts are monitored in near real-time or post event on a remote computer to determine legal hits and hence derivative measures like scoring and final outcomes. It is hoped that this system can be applied to reduce the need for full contact contests as well as provide a more reliable method of determining the outcome of a bout. Other benefits presented here include the ability to analyse an athlete's performance post match or training session, such as assessing the efficacy of training drills and effects of fatigue.

  11. NGOs and government partnership for health systems strengthening: A qualitative study presenting viewpoints of government, NGOs and donors in Pakistan

    Directory of Open Access Journals (Sweden)

    Rizvi Narjis

    2011-05-01

    Full Text Available Abstract Background Health systems are expected to serve the population needs in an effective, efficient and equitable manner. Therefore, the importance of strengthening of public, private and community health systems has been emphasized time and again. In most of the developing countries, certain weaknesses and gaps in the government health systems have been hampering the achievement of improved health outcomes. Public sector in Pakistan has been deficient in the capacity to deliver equitable and quality health services and thus has been grossly underutilized. Methods A qualitative study comprising in-depth interviews was conducted capturing the perceptions of the government functionaries, NGO representatives and donor community about the role and position of NGOs in health systems strengthening in Pakistan's context. Analysis of the data was done manually to generate nodes, sub-nodes and themes. Results Since many years, international and local non-governmental organizations (NGOs have endeavored to fill the gaps in health service delivery, research and advocacy. NGOs have relatively performed better and achieved the results because of the flexible planning and the ability to design population based projects on health education, health promotion, social marketing, community development and advocacy. This paper captures the need and the opportunity of public private partnership in Pakistan and presents a framework for a meaningful engagement of the government and the private and nonprofit NGOs. Conclusion Involving the NGOs for health system strengthening may eventually contribute to create a healthcare system reflecting an increased efficiency, more equity and good governance in the wake of the Millennium Development Goals. Nevertheless, few questions need to be answered and pre-requisites have to be fulfilled before moving on.

  12. Proposing melasma severity index: A new, more practical, office-based scoring system for assessing the severity of melasma

    Directory of Open Access Journals (Sweden)

    Imran Majid

    2016-01-01

    Full Text Available Background: Melasma Area and Severity Index (MASI, the scoring system in melasma, needs to be refined. Aims and Objectives: To propose a more practical scoring system, named as Melasma Severity Index (MSI, for assessing the disease severity and treatment response in melasma. Materials and Methods: Four dermatologists were trained to calculate MASI and also the proposed MSI scores. For MSI, the formula used was 0.4 (a × p 2 l + 0.4 (a × p 2 r + 0.2 (a × p 2 n where "a" stands for area, "p" for pigmentation, "l" for left face, "r" for right face, and "n" for nose. On a single day, 30 enrolled patients were randomly examined by each trained dermatologist and their MASI and MSI scores were calculated. Next, each rater re-examined every 6 th patient for repeat MASI and MSI scoring to assess intra- and inter-rater reliability of MASI and MSI scores. Validity was assessed by comparing the individual scores of each rater with objective data from mexameter and ImageJ software. Results: Inter-rater reliability, as assessed by intraclass correlation coefficient, was significantly higher for MSI (0.955 as compared to MASI (0.816. Correlation of scores with objective data by Spearman′s correlation revealed higher rho values for MSI than for MASI for all raters. Limitations: Sample population belonged to a single ethnic group. Conclusions: MSI is simpler and more practical scoring system for melasma.

  13. Allegheny County Walk Scores

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Walk Score measures the walkability of any address using a patented system developed by the Walk Score company. For each 2010 Census Tract centroid, Walk Score...

  14. Benefit of revascularisation to critical limb ischaemia patients evaluated by a patient-oriented scoring system.

    Science.gov (United States)

    Chisci, E; Perulli, A; Iacoponi, F; Setacci, F; de Donato, G; Palasciano, G; Cappelli, A; Setacci, C

    2012-05-01

    The concept of patency and limb salvage are physician-oriented endpoints in critical limb ischaemia (CLI). These endpoints have failed to enhance function after revascularisation. The aim of this study was to create a scoring system to predict 1-year functional status and to assess the benefit to patients possible by revascularisation. During the period 2007-2009, 480 consecutive patients (mean age ± SD, 83.2 ± 8.7 years) underwent repair for CLI. Preoperative, operative and functional status characteristics and post-operative outcomes were recorded. The following patient-oriented outcomes were investigated pre- and postoperatively: basic and instrumental activities of daily living (BADL and IADL) and ambulatory and living status. Statistical analysis was performed to assess predictors of functional benefit from revascularisation. The variables significant on multivariable analysis were used to generate a scoring system to pre and postoperatively grade individual patient risk of losing baseline functional status at 1 year (CLI functional score). Ninety-three of 480 patients (19.3%) were in Rutherford class IV, 208 (43.3%) in class V and 179 (37.4%) in class VI. Surgical, endovascular and hybrid operations were performed in 108 (22.5%), 319 (66.5%) and 53 (11%) patients, respectively; mean follow-up was 408 ± 363 days. Improved or unchanged functional status was observed in 276 patients (57.5%). Preoperative mean ± SD BADL and IADL (4.26 ± 1.98 and 3.92 ± 2.69, respectively) were modified from mean values at 1-year follow-up (4.19 ± 2.06 and 4.12 ± 3, respectively) (p = 0.401 and p 80% indicates that patients are likely to lose functional abilities and require assistance for ambulation or ADL, as well as risking outcomes such as major amputation, new CLI-related hospitalisation or re-operation (p 2 cm, infection and poor tibial runoff), American Society of Anesthesiologists (ASA) score > II, previous cerebrovascular event and heart

  15. Simple Scoring System and Artificial Neural Network for Knee Osteoarthritis Risk Prediction: A Cross-Sectional Study

    Science.gov (United States)

    Yoo, Tae Keun; Kim, Deok Won; Choi, Soo Beom; Oh, Ein; Park, Jee Soo

    2016-01-01

    Background Knee osteoarthritis (OA) is the most common joint disease of adults worldwide. Since the treatments for advanced radiographic knee OA are limited, clinicians face a significant challenge of identifying patients who are at high risk of OA in a timely and appropriate way. Therefore, we developed a simple self-assessment scoring system and an improved artificial neural network (ANN) model for knee OA. Methods The Fifth Korea National Health and Nutrition Examination Surveys (KNHANES V-1) data were used to develop a scoring system and ANN for radiographic knee OA. A logistic regression analysis was used to determine the predictors of the scoring system. The ANN was constructed using 1777 participants and validated internally on 888 participants in the KNHANES V-1. The predictors of the scoring system were selected as the inputs of the ANN. External validation was performed using 4731 participants in the Osteoarthritis Initiative (OAI). Area under the curve (AUC) of the receiver operating characteristic was calculated to compare the prediction models. Results The scoring system and ANN were built using the independent predictors including sex, age, body mass index, educational status, hypertension, moderate physical activity, and knee pain. In the internal validation, both scoring system and ANN predicted radiographic knee OA (AUC 0.73 versus 0.81, p<0.001) and symptomatic knee OA (AUC 0.88 versus 0.94, p<0.001) with good discriminative ability. In the external validation, both scoring system and ANN showed lower discriminative ability in predicting radiographic knee OA (AUC 0.62 versus 0.67, p<0.001) and symptomatic knee OA (AUC 0.70 versus 0.76, p<0.001). Conclusions The self-assessment scoring system may be useful for identifying the adults at high risk for knee OA. The performance of the scoring system is improved significantly by the ANN. We provided an ANN calculator to simply predict the knee OA risk. PMID:26859664

  16. A New Weighted Injury Severity Scoring System: Better Predictive Power for Pediatric Trauma Mortality.

    Science.gov (United States)

    Shi, Junxin; Shen, Jiabin; Caupp, Sarah; Wang, Angela; Nuss, Kathryn E; Kenney, Brian; Wheeler, Krista K; Lu, Bo; Xiang, Henry

    2018-05-02

    An accurate injury severity measurement is essential for the evaluation of pediatric trauma care and outcome research. The traditional Injury Severity Score (ISS) does not consider the differential risks of the Abbreviated Injury Scale (AIS) from different body regions nor is it pediatric specific. The objective of this study was to develop a weighted injury severity scoring (wISS) system for pediatric blunt trauma patients with better predictive power than ISS. Based on the association between mortality and AIS from each of the six ISS body regions, we generated different weights for the component AIS scores used in the calculation of ISS. The weights and wISS were generated using the National Trauma Data Bank (NTDB). The Nationwide Emergency Department Sample (NEDS) was used to validate our main results. Pediatric blunt trauma patients less than 16 years were included, and mortality was the outcome. Discrimination (areas under the receiver operating characteristic curve, sensitivity, specificity, positive predictive value, negative predictive value, concordance) and calibration (Hosmer-Lemeshow statistic) were compared between the wISS and ISS. The areas under the receiver operating characteristic curves from the wISS and ISS are 0.88 vs. 0.86 in ISS=1-74 and 0.77 vs. 0.64 in ISS=25-74 (ppredictive value, negative predictive value, and concordance when they were compared at similar levels of sensitivity. The wISS had better calibration (smaller Hosmer-Lemeshow statistic) than the ISS (11.6 versus 19.7 for ISS=1-74 and 10.9 versus 12.6 for ISS= 25-74). The wISS showed even better discrimination with the NEDS. By weighting the AIS from different body regions, the wISS had significantly better predictive power for mortality than the ISS, especially in critically injured children.Level of Evidence and study typeLevel IV Prognostic/Epidemiological.

  17. Development of a novel scoring system for identifying emerging chemical risks in the food chain.

    Science.gov (United States)

    Oltmanns, J; Licht, O; Bitsch, A; Bohlen, M-L; Escher, S E; Silano, V; MacLeod, M; Serafimova, R; Kass, G E N; Merten, C

    2018-02-21

    The European Food Safety Authority (EFSA) is responsible for risk assessment of all aspects of food safety, including the establishment of procedures aimed at the identification of emerging risks to food safety. Here, a scoring system was developed for identifying chemicals registered under the European REACH Regulation that could be of potential concern in the food chain using the following parameters: (i) environmental release based on maximum aggregated tonnages and environmental release categories; (ii) biodegradation in the environment; (iii) bioaccumulation and in vivo and in vitro toxicity. The screening approach was tested on 100 data-rich chemicals registered under the REACH Regulation at aggregated volumes of at least 1000 tonnes per annum. The results show that substance-specific data generated under the REACH Regulation can be used to identify potential emerging risks in the food chain. After application of the screening procedure, priority chemicals can be identified as potentially emerging risk chemicals through the integration of exposure, environmental fate and toxicity. The default approach is to generate a single total score for each substance using a predefined weighting scenario. However, it is also possible to use a pivot table approach to combine the individual scores in different ways that reflect user-defined priorities, which enables a very flexible, iterative definition of screening criteria. Possible applications of the approaches are discussed using illustrative examples. Either approach can then be followed by in-depth evaluation of priority substances to ensure the identification of substances that present a real emerging chemical risk in the food chain.

  18. Donor Tracker: An Innovative Real-Time Tracking System for Blood ...

    African Journals Online (AJOL)

    User

    According to a research report (Ionut, 2009), smart phones with GPS will increase in number by ... technology for ubiquitous computing systems (Wikipedia). Context-aware .... Figure 5.4.1: Home page of the server-side application. Figure 5.4.2 ...

  19. Comparison of an expert system with other clinical scores for the evaluation of severity of asthma.

    Science.gov (United States)

    Gautier, V; Rédier, H; Pujol, J L; Bousquet, J; Proudhon, H; Michel, C; Daurès, J P; Michel, F B; Godard, P

    1996-01-01

    "Asthmaexpert" was produced at the special request of several clinicians in order to obtain a better understanding of the medical decisions taken by clinical experts in the management of asthmatic patients. In order to assess the severity of asthma, a new score called Artificial Intelligence score (AI score), produced by Asthmaexpert, was compared with three other scores (Aas, Hargreave and Brooks). One hundred patients were enrolled prospectively in the study during their first consultation in the out-patient clinic. Distribution of severity level according to the different scores was studied, and the reliability between AI and other scores was evaluated by Kappa and MacNemar tests. Correlations with functional parameters were performed. The AI score assessed higher levels of severity than the other scores (Kappa = 18, 28 and 10% for Aas, Hargreave and Brooks, respectively) with significant MacNemar test in all cases. There was a significant correlation between AI score and forced expiratory volume in one second (FEV1) (r = 0.73). These data indicate that the AI score is a severity score which defines higher levels of severity than the chosen scores. Correlations for functional parameters are good. This score appears easy to use for the first consultation of an asthmatic patient.

  20. The Pancreatitis Activity Scoring System predicts clinical outcomes in acute pancreatitis: findings from a prospective cohort study.

    Science.gov (United States)

    Buxbaum, James; Quezada, Michael; Chong, Bradford; Gupta, Nikhil; Yu, Chung Yao; Lane, Christianne; Da, Ben; Leung, Kenneth; Shulman, Ira; Pandol, Stephen; Wu, Bechien

    2018-03-15

    The Pancreatitis Activity Scoring System (PASS) has been derived by an international group of experts via a modified Delphi process. Our aim was to perform an external validation study to assess for concordance of the PASS score with high face validity clinical outcomes and determine specific meaningful thresholds to assist in application of this scoring system in a large prospectively ascertained cohort. We analyzed data from a prospective cohort study of consecutive patients admitted to the Los Angeles County Hospital between March 2015 and March 2017. Patients were identified using an emergency department paging system and electronic alert system. Comprehensive characterization included substance use history, pancreatitis etiology, biochemical profile, and detailed clinical course. We calculated the PASS score at admission, discharge, and at 12 h increments during the hospitalization. We performed several analyses to assess the relationship between the PASS score and outcomes at various points during hospitalization as well as following discharge. Using multivariable logistic regression analysis, we assessed the relationship between admission PASS score and risk of severe pancreatitis. PASS score performance was compared to established systems used to predict severe pancreatitis. Additional inpatient outcomes assessed included local complications, length of stay, development of systemic inflammatory response syndrome (SIRS), and intensive care unit (ICU) admission. We also assessed whether the PASS score at discharge was associated with early readmission (re-hospitalization for pancreatitis symptoms and complications within 30 days of discharge). A total of 439 patients were enrolled, their mean age was 42 (±15) years, and 53% were male. Admission PASS score >140 was associated with moderately severe and severe pancreatitis (OR 3.5 [95% CI 2.0, 6.3]), ICU admission (OR 4.9 [2.5, 9.4]), local complications (3.0 [1.6, 5.7]), and development of SIRS (OR 2.9 [1

  1. Ratio analysis and Piotroski scoring system in the automobile industry in Croatia

    Directory of Open Access Journals (Sweden)

    Morana Mesarić

    2014-10-01

    Full Text Available To gain insight into operational efficiency, sustainable profitability, the ability to fulfil commitments, use of funds borrowed or investment risk or operational self-sufficiency, it is necessary to conduct analyses of financial statements usually known as ratio analysis. The paper provides analyses of five Croatian general distributors of the automobile industry. Ratios used in the analyses are those used in the Piotroski f-scoring analyses, which are famous for assessing financial capacities of enterprises on the stock exchange market. Based on ratios used in Piotroski scoring systems the assessment of five enterprises, as well as the sector as a whole was carried out. The analysis covers the period 2007-2012. That is the period of the rise, falling and recovery of the automotive industry throughout the world as well as the rise, falling and recession of the whole economy including the automobile market. In general, the sector itself is financially unstable and consequently risk exposed. Results are used for preliminary analyses and prediction of the future financial strength of the auto industry in Croatia.

  2. Electrocardiographic characteristics and clinical features of acute apical infarction. Analysis by a QRS scoring system

    Energy Technology Data Exchange (ETDEWEB)

    Seino, Yoshihiko; Nagae, Yasuhiro; Kamei, Shinichiro; Koh, Yoshiki; Tanaka, Keiji; Katoh, Takao; Takano, Teruo; Hayakawa, Hirokazu; Okumura, Hidemasa

    1986-11-01

    Two-dimensional echocardiography and thallium-201 myocardial single photon emission computed tomography were used to detect infarct site in 56 consecutive patients with acute myocardial infarction (MI). The pathophysiology of apical MI at acute stage was studied in relation to ECG changes as determined by a QRS scoring system. On the first hospital day, the group with antero-apical MI (AAp group) had long Q-wave durations in leads V/sub 3/ and V/sub 4/, high QRS scores (QRSs) in leads V/sub 4/ and V/sub 5/, high QRSs in total, and large number of Q waves, as compared with the group with anterior MI (A group). On the 7th day, Q-wave durations in leads V/sub 2/ and V/sub 3/, and QRSs in leads V/sub 4/ and V/sub 5/ were significantly larger in AAp group than A group. Although there was no significant difference between the two groups with respect to blood circulation and peak creatine kinase (CK)/CK-MB at the time of admission, left ventricular ejection function was significantly lower in AAp group than A group. No finding was significantly different between the group with infero-apical MI and the group with inferior MI. QRSs in leads V/sub 4/ and V/sub 5/ was a useful means of diagnosing AAp MI. (Namekawa, K.).

  3. A quantitative assessment of alkaptonuria: testing the reliability of two disease severity scoring systems.

    Science.gov (United States)

    Cox, Trevor F; Ranganath, Lakshminarayan

    2011-12-01

    Alkaptonuria (AKU) is due to excessive homogentisic acid accumulation in body fluids due to lack of enzyme homogentisate dioxygenase leading in turn to varied clinical manifestations mainly by a process of conversion of HGA to a polymeric melanin-like pigment known as ochronosis. A potential treatment, a drug called nitisinone, to decrease formation of HGA is available. However, successful demonstration of its efficacy in modifying the natural history of AKU requires an effective quantitative assessment tool. We have described two potential tools that could be used to quantitate disease burden in AKU. One tool describes scoring the clinical features that includes clinical assessments, investigations and questionnaires in 15 patients with AKU. The second tool describes a scoring system that only includes items obtained from questionnaires used in 44 people with AKU. Statistical analyses were carried out on the two patient datasets to assess the AKU tools; these included the calculation of Chronbach's alpha, multidimensional scaling and simple linear regression analysis. The conclusion was that there was good evidence that the tools could be adopted as AKU assessment tools, but perhaps with further refinement before being used in the practical setting of a clinical trial.

  4. Biological markers in Helicobacter pylori-associated gastritis and carcinoma: the value of a scoring system

    International Nuclear Information System (INIS)

    Mourad, Walid A.; El-Husseiny, Gamal; Shoukri, Mohamed; Rezeig, Mohamed; Chianzentonieu, N.; Amin, Tarek

    2004-01-01

    Helicobacter pylori-associated gastritis has been linked to the pathogenesis of gastric adenocarcinoma (GA), especially when assciated with intestinal metaplasia (IM) and atypia/dysplasia (A/D). We examined p53 expression, ploidy and proliferative activity and assessed H.pylori infection in relationship to IM and A/Din case of gastritis not associated with GA and in cases of GA. We examined 53 gastric biopsies from patients with gastritis not associated with GA, including patients with IM and/or A/D (n=35) and with gastritis associated with IM and/or A/D (n=21). Thirty-six distal gastrectomy specimens from patients with GA constituted a third group of patients. A scoring system that encompassed the presence or absence of H.Pylori, degree of gastritis, IM and/or A/D, p53, MIB-1prolefarative index (MPI) and ploidy was estimated in the cases of gastritis and in cancer associated mucosa (CAM) and the adenocarcinoma from patients withGA. Patients with GA had a higher median age than those with gastritis without IM and more were males (ratio 2.2:1). H.pylori was detected in 75% (40/53) of gastritis specimen and in 55% (20/36) of GA cases. There was a statistically significant difference between the incidence of gastritis without IM and/or A/D and CAM (p=0.01). p53 expression was seen in 67% of the cases (14/21) of gastritis with IM and/or A/D and only in 5% (2 cases ) of gastritis without IM (p=0.0005). A statistically significant difference in MPI was seen between CAM and GA (p=0.01) and gastritis without IM and/or A/D and gastritis with IM(p=0.004). Cases of gastritis without IM and/or or A/D has a median score of 8 while cases of gastritis with IM and/or A/D had a median score of 12 (p=0.0003). CAM had a median score of 13, which was significantly different than gastritis without IM and/or A/D(p=0.0003) The presence of IM and/or A/D can be used in H.pylori -associated gastritis as as starting point to further investigate high risk lesions. Those showing p53 expression

  5. Short communication: A reproductive tract scoring system to manage fertility in lactating dairy cows.

    Science.gov (United States)

    Young, C D; Schrick, F N; Pohler, K G; Saxton, A M; Di Croce, F A; Roper, D A; Wilkerson, J B; Edwards, J L

    2017-07-01

    We developed a reproductive tract size and position score (SPS) system as a reproductive management tool to identify lactating dairy cows with decreased fertility. This system, relying solely on transrectal palpation, considers the size (cervical and uterine) and position of the reproductive tract relative to the pelvis. Cows undergoing pre-breeding exams were identified as having reproductive tracts that were small (SPS1), medium (SPS2), or large (SPS3). Cows designated SPS1 had small and compact uterine horns that rested within the pelvic cavity; SPS2 cows had reproductive tracts that were intermediate in cervical and uterine horn diameter, with longer uterine horns resting partially outside the pelvic cavity; and SPS3 cows had reproductive tracts that were larger and rested mostly outside the pelvic cavity. Cows that were SPS1 had a higher rate of pregnancy per artificial insemination (43.3 ± 3.7%) than cows that were SPS2 (36.9 ± 3.6%) or SPS3 (27.7 ± 4.3%). The percentage of cows with an SPS2 score differed in pregnancies per artificial insemination compared with SPS3 cows. The average days in milk was similar for SPS1, SPS2, and SPS3 cows (104.3 ± 3.5, 98.4 ± 3.4, and 94.7 ± 7.7, respectively). Ultrasound measurements of the uterine horn and cervical diameter, and length measurements of the uterine horns, cervix, and vagina confirmed differences among the SPS groups derived by transrectal palpation. The ease with which transrectal palpation can be used to determine the size and position of the reproductive tract attests to the relevance and usefulness of this scoring system to identify less fertile lactating dairy cows. The ability to do so with ease provides an opportunity to make economically relevant management decisions and maximize reproductive efficiency in a given herd. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  6. Comparison of three scoring systems for risk stratification in elderly patients wıth acute upper gastrointestinal bleeding.

    Science.gov (United States)

    Kalkan, Çağdaş; Soykan, Irfan; Karakaya, Fatih; Tüzün, Ali; Gençtürk, Zeynep Bıyıklı

    2017-04-01

    Acute gastrointestinal bleeding is a potentially life-threatening condition that requires rapid assessment and dynamic management. Several scoring systems are used to predict mortality and rebleeding in such cases. The aim of the present study was to compare three scoring systems for predicting short-term mortality, rebleeding, duration of hospitalization and the need for blood transfusion in elderly patients with upper gastrointestinal bleeding. The present study included 335 elderly patients with upper gastrointestinal bleeding. Pre- and post-endoscopic Rockall, Glasgow-Blatchford and AIMS65 scores were calculated. The ability of these scores to predict rebleeding, mortality, duration of hospitalization and the need for blood transfusion was determined. Pre- (4.5) and post-endoscopic (7.5) Rockall scores were superior to the Glasgow-Blatchford (12.5) score for predicting mortality (P = 0.006 and P = 0.015). Likewise, pre- (4.5) and post-endoscopic Rockall scores were superior to the respective Glasgow-Blatchford scores for predicting rebleeding (P = 0.013 and P = 0.03). There was an association between duration of hospitalization and mortality; as the duration of hospitalization increased the mortality rate increased. In all, 94% of patients hospitalized for a mean of 5 days were alive versus 56.1% of those hospitalized for 20 days, and 20.2% of those hospitalized for 40 days. In elderly patients with upper gastrointestinal bleeding, the Rockall score is clinically more useful for predicting mortality and rebleeding than the Glasgow-Blatchford and AIMS65 scores; however, for predicting duration of hospitalization and the need for blood transfusion, the Glasgow-Blatchford score is superior to the Rockall and AIMS65 scores. Geriatr Gerontol Int 2017; 17: 575-583. © 2016 Japan Geriatrics Society.

  7. A chest radiograph scoring system in patients with severe acute respiratory infection: a validation study

    International Nuclear Information System (INIS)

    Taylor, Emma; Haven, Kathryn; Reed, Peter; Bissielo, Ange; Harvey, Dave; McArthur, Colin; Bringans, Cameron; Freundlich, Simone; Ingram, R. Joan H.; Perry, David; Wilson, Francessa; Milne, David; Modahl, Lucy; Huang, Q. Sue; Gross, Diane; Widdowson, Marc-Alain; Grant, Cameron C.

    2015-01-01

    The term severe acute respiratory infection (SARI) encompasses a heterogeneous group of respiratory illnesses. Grading the severity of SARI is currently reliant on indirect disease severity measures such as respiratory and heart rate, and the need for oxygen or intensive care. With the lungs being the primary organ system involved in SARI, chest radiographs (CXRs) are potentially useful for describing disease severity. Our objective was to develop and validate a SARI CXR severity scoring system. We completed validation within an active SARI surveillance project, with SARI defined using the World Health Organization case definition of an acute respiratory infection with a history of fever, or measured fever of ≥ 38 °C; and cough; and with onset within the last 10 days; and requiring hospital admission. We randomly selected 250 SARI cases. Admission CXR findings were categorized as: 1 = normal; 2 = patchy atelectasis and/or hyperinflation and/or bronchial wall thickening; 3 = focal consolidation; 4 = multifocal consolidation; and 5 = diffuse alveolar changes. Initially, four radiologists scored CXRs independently. Subsequently, a pediatrician, physician, two residents, two medical students, and a research nurse independently scored CXR reports. Inter-observer reliability was determined using a weighted Kappa (κ) for comparisons between radiologists; radiologists and clinicians; and clinicians. Agreement was defined as moderate (κ > 0.4–0.6), good (κ > 0.6–0.8) and very good (κ > 0.8–1.0). Agreement between the two pediatric radiologists was very good (κ = 0.83, 95 % CI 0.65–1.00) and between the two adult radiologists was good (κ = 0.75, 95 % CI 0.57–0. 93). Agreement of the clinicians with the radiologists was moderate-to-good (pediatrician:κ = 0.65; pediatric resident:κ = 0.69; physician:κ = 0.68; resident:κ = 0.67; research nurse:κ = 0.49, medical students: κ = 0.53 and κ = 0.56). Agreement between clinicians was good-to-very good

  8. The accuracy of Internet search engines to predict diagnoses from symptoms can be assessed with a validated scoring system.

    Science.gov (United States)

    Shenker, Bennett S

    2014-02-01

    To validate a scoring system that evaluates the ability of Internet search engines to correctly predict diagnoses when symptoms are used as search terms. We developed a five point scoring system to evaluate the diagnostic accuracy of Internet search engines. We identified twenty diagnoses common to a primary care setting to validate the scoring system. One investigator entered the symptoms for each diagnosis into three Internet search engines (Google, Bing, and Ask) and saved the first five webpages from each search. Other investigators reviewed the webpages and assigned a diagnostic accuracy score. They rescored a random sample of webpages two weeks later. To validate the five point scoring system, we calculated convergent validity and test-retest reliability using Kendall's W and Spearman's rho, respectively. We used the Kruskal-Wallis test to look for differences in accuracy scores for the three Internet search engines. A total of 600 webpages were reviewed. Kendall's W for the raters was 0.71 (psearch engines is a valid and reliable instrument. The scoring system may be used in future Internet research. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Development of organ-specific donor risk indices.

    Science.gov (United States)

    Akkina, Sanjeev K; Asrani, Sumeet K; Peng, Yi; Stock, Peter; Kim, W Ray; Israni, Ajay K

    2012-04-01

    Because of the shortage of deceased donor organs, transplant centers accept organs from marginal deceased donors, including older donors. Organ-specific donor risk indices have been developed to predict graft survival with various combinations of donor and recipient characteristics. Here we review the kidney donor risk index (KDRI) and the liver donor risk index (LDRI) and compare and contrast their strengths, limitations, and potential uses. The KDRI has a potential role in developing new kidney allocation algorithms. The LDRI allows a greater appreciation of the importance of donor factors, particularly for hepatitis C virus-positive recipients; as the donor risk index increases, the rates of allograft and patient survival among these recipients decrease disproportionately. The use of livers with high donor risk indices is associated with increased hospital costs that are independent of recipient risk factors, and the transplantation of livers with high donor risk indices into patients with Model for End-Stage Liver Disease scores indices for liver transplantation, including donor-recipient matching and the retransplant donor risk index. Although substantial progress has been made in developing donor risk indices to objectively assess donor variables that affect transplant outcomes, continued efforts are warranted to improve these indices to enhance organ allocation policies and optimize allograft survival. Copyright © 2012 American Association for the Study of Liver Diseases.

  10. Pediatric Early Warning Score Systems, Nurses Perspective - A Focus Group Study

    DEFF Research Database (Denmark)

    Jensen, Claus Sixtus; Nielsen, Pia Bonde; Olesen, Hanne Vebert

    2018-01-01

    PURPOSE: Pediatric early warning score (PEWS) systems are used to monitor pediatric patients' vital signs and facilitate the treatment of patients at risk of deteriorating. The aim of this study was to gain knowledge about nurses' experiences with PEWS and to highlight factors facilitating...... and impeding the use of PEWS tools in clinical practice. DESIGN AND METHODS: An exploratory qualitative design was chosen using focus group interviews to gain a deeper understanding of nurses' experiences with PEWS. A total of five focus group interviews were conducted at three hospitals, and a qualitative......'s - a challenge, v) PEWS helps to visualize the need for escalating care, vi) an inflexible and challenging tool, and vii) supportive tools enhance the nurses' experiences of PEWS positively. CONCLUSIONS: Our findings suggest that attention should be given to nurses' perceptions of how both clinical judgment...

  11. Serum Zinc Level and Its Correlation with Vesikari System Scoring in Acute Pediatric Diarrhea.

    Science.gov (United States)

    Eskander, Ayman E; Sherif, Lobna S; Nabih, Mohammad; Baroudy, Nevine R El; Marcos, Ghobrial C; Badawy, Ehsan A; Refay, Amira S El

    2017-08-15

    Diarrhea remains the most common infectious disease worldwide. Zinc has been studied extensively recently for its potential effect on prevention, control and treatment of acute diarrhoea. This study was designed to correlate the level of zinc with the severity of pediatric diarrhoea estimated by Vesikari Scoring System. The present study included 80 children aged two months to 30 months from those suffering from the acute diarrheal episode and admitted to Pediatric Hospital "Abo El Rish" Cairo University. Serum Zinc level was assessed by a colorimetric method with a spectrophotometer. Zinc deficiency was detected in 45 (56.2%) patient of the studied group Significant negative correlations were found between serum zinc level and severity of dehydration and duration of hospitalization (p Zinc level has an essential role in acute pediatric diarrhoea. Zinc therapy should be considered beside Oral rehydration salts (ORS) to achieve maximum impact on diarrheal diseases; clinical trials are recommended to support the zinc supplementation in developing countries.

  12. Moderate precision of prognostic scoring systems in a consecutive, prospective cohort of 544 patients with metastatic spinal cord compression

    DEFF Research Database (Denmark)

    Morgen, Søren Schmidt; Nielsen, Dennis Hallager; Larsen, Claus Falck

    2014-01-01

    and compared to the observed survival. We assessed how precise the scoring systems predicted survival with McNemar's test. The prognostic value was illustrated with Kaplan-Meier curves, and the individual prognostic components were analyzed with Cox regression analysis. RESULTS: The mean age was 65 years...... (range 20-95), and 57 % of the patients were men. The majority of tumors were lung (23 %), prostate (21 %), and breast tumors (18 %). The overall precision of predicted survival was 58.7 % for the Tokuhashi Revised score and 52.9 % for the Tomita score. The observed survival in each of the scoring groups...... was most precise in predicting survival. However, due to the relatively low precision, we suggest that a modification of both scoring systems is necessary....

  13. Nyretransplantation med levende donor

    DEFF Research Database (Denmark)

    Kamper, A L; Løkkegaard, H; Rasmussen, F

    2000-01-01

    In recent years transplantation from living donors has accounted for 25-30% of all kidney transplants in Denmark corresponding to 40-45 per year. Most of these living donors are parents or siblings, although internationally an increasing number are unrelated donors. Donor nephrectomy is associate...... in cadaver transplantation. The ethical and psychological aspects related to transplantation from a living donor are complex and need to be carefully evaluated when this treatment is offered to the patients....

  14. MR score system on spatium perilymphaticum gadolinium opacification and its application for diagnosis of Meniere's disease

    International Nuclear Information System (INIS)

    Fang Zheming; Liu Ying; Cao Dairong; Chen Xi

    2012-01-01

    Objective: To propose a MR scoring methods for spatium perilymphaticum gadolinium opacification and explore the value of their diagnosis of Meniere's disease. Methods: Fifty-one asymptomatic and 65 symptomatic patients with Meniere's disease were enrolled in this study. MR imaging of spatium perilymphaticum after intratypanic gadolinium injection were analyzed with following scoring method. (1) Semicircular canal not visualized equal to score 0; some visualized equal score 1; full visualized equal score 2.(2)There were high-signal and low-signal in the vestibule, low-signal areas above the lateral semicircular canal plane equal score 6; low signal areas down to lateral semicircular canal plane equal score 3; no higher signal in the vestibule area equal score 0. (3) Basal turn of cochlea: full visualized equal score 3; part visualized equal score 2; scala vestibule of basal turn smaller than scala tympani equal score 1 regardless of full or visualized in basal turn; no visualized equal score 0. Medial turn of cochlea: full visualized equal score 2; part visualized equal score 1; no visualized equal score 0. Apical turn of cochlea: visualized equal score 1; no visualized equal score 0. One radiologist scored all cases with double blind. SPSS 17.0 software was used to conduct multiple independent-samples nonparametric tests, multivariate Logistic regression, and ROC curve analysis. Evaluate the sensitivity and specificity for diagnosis of Meniere's disease with the scoring system. Results: (1) Meniere's disease summation score 0 to 12, median 9 (quarter spacing 4.5); no symptoms group summation score 15 to 18,median 17 (quarter spacing 3), two group differences has statistics significance (Wilcoxon rank and inspection U=-9.118, P=0.00). (2) Based on summation score for the diagnosis of Meniere's disease, tangent point was 14.5, Youden index 0.969, specificity 100.0%, sensitivity 96.9%.(3) Let cochlear, vestibular, semicircular canal scoring

  15. Evaluation and Development of Pavement Scores, Performance Models and Needs Estimates for the TXDOT Pavement Management Information System : Final Report

    Science.gov (United States)

    2012-10-01

    This project conducted a thorough review of the existing Pavement Management Information System (PMIS) database, : performance models, needs estimates, utility curves, and scores calculations, as well as a review of District practices : concerning th...

  16. A modified risk assessment scoring system for post laser in situ keratomileusis ectasia in topographically normal patients

    Directory of Open Access Journals (Sweden)

    Mohammad Miraftab

    2014-01-01

    Conclusion: Our modified ectasia risk scoring system for patients with normal corneal topography can predict post LASIK ectasia risk with acceptable sensitivity and specificity. However, there are still unidentified risk factors for which further studies are required.

  17. Formulating A Performance Measurement System using Balanced Score Card in Islamic Philanthropy Institutions

    Directory of Open Access Journals (Sweden)

    Sani A’ieshah Abdullah

    2017-01-01

    Full Text Available The introduction of Balanced Score Card (BSC as one of the management accounting tool to measure the performance of companies in both aspect of financial and non-financial position has been predominantly used since 1992 and had resulted positive energies for the profit making companies. Hence, the extension of the BSC is also required to help the social business organisation in delivering their multiple bottom lines in the most effective ways and provide organisations a mechanism to track their performance holistically through both quantitative and qualitative information. The growing of Islamic Philanthropy Institutions (IPI especially in Malaysia with the objective to promote social development based on the charitable activities has been acknowledged by the society. Therefore, in order to ensure the sustainability of these institutions, a proper measurement system is required to ensure the final goal of the institutions is achievable and successful. Thus, the objective of this paper is to formulate the main indicators and variables that are suitable to measure the IPIs based on BSC system in four main perspectives which are financial perspective, stakeholder’s perspective, internal process perspective and learning and growth perspective. The uniqueness of the establishment of IPIs would require different indicators and variables which are more appropriate as compared with the profit sector organisations. The outcome of this study could provide clear picture and guidelines in designing a proper performance measurement system to be implemented by current IPIs in Malaysia in order to maintain the sustainability and competitiveness of this institutions in future.

  18. Biomarkers, lactate, and clinical scores as outcome predictors in systemic poisons exposures.

    Science.gov (United States)

    Lionte, C; Sorodoc, V; Tuchilus, C; Cimpoiesu, D; Jaba, E

    2017-07-01

    Acute exposure to systemic poisons represents an important challenge in clinical toxicology. We aimed to analyze the potential role of cardiac biomarkers, routine laboratory tests, and clinical scores as morbidity and in-hospital mortality predictors in patients intoxicated with various systemic poisons. We conducted a prospective study on adults acutely exposed to systemic poisons. We determined the PSS, Glasgow Coma Scale (GCS), and we performed electrocardiogram, laboratory tests, lactate and cardiac biomarkers (which were reassessed 4 h, respectively 6 h later). Of 120 patients included, 45% developed complications, 19.2% had a poor outcome, and 5% died. Multivariate logistic regression sustained lactate (odds ratio (OR) 1.58; confidence interval (CI) 95%: 0.97-2.59; p 0.066), MB isoenzyme of creatine kinase (6h-CKMB; OR 1.08; CI 95%: 1.02-1.16; p 0.018) as predictors for a poor outcome. A GCS poisons exposure. Receiver operating characteristic analysis showed that brain natriuretic peptide (area under the curve (AUC), 0.96; CI 95%: 0.92-0.99; p poisons exposure.

  19. Candida Endophthalmitis After Descemet Stripping Automated Endothelial Keratoplasty With Grafts From Both Eyes of a Donor With Possible Systemic Candidiasis.

    Science.gov (United States)

    Palioura, Sotiria; Sivaraman, Kavitha; Joag, Madhura; Sise, Adam; Batlle, Juan F; Miller, Darlene; Espana, Edgar M; Amescua, Guillermo; Yoo, Sonia H; Galor, Anat; Karp, Carol L

    2018-04-01

    To report 2 cases with late postoperative Candida albicans interface keratitis and endophthalmitis after Descemet stripping automated endothelial keratoplasty (DSAEK) with corneal grafts originating from a single donor with a history of presumed pulmonary candidiasis. Two patients underwent uncomplicated DSAEK by 2 corneal surgeons at different surgery centers but with tissue from the same donor and were referred to the Bascom Palmer Eye Institute with multifocal infiltrates at the graft-host cornea interface 6 to 8 weeks later, and anterior chamber cultures that were positive for the same genetic strain of C. albicans. Immediate explantation of DSAEK lenticules and daily intracameral and instrastromal voriconazole and amphotericin injections failed to control the infection. Thus, both patients underwent therapeutic penetrating keratoplasty with intraocular lens explantation, pars plana vitrectomy, and serial postoperative intraocular antifungal injection. Both patients are doing well at 2 years postoperatively with best-corrected vision of 20/20 and 20/30+ with rigid gas permeable lenses. One patient required repeat optical penetrating keratoplasty and glaucoma tube implantation 1 year after the original surgery. Literature review reveals that donor lenticule explantation and intraocular antifungals are often inadequate to control fungal interface keratitis, and a therapeutic graft is commonly needed. Interface fungal keratitis and endophthalmitis due to infected donor corneal tissue is difficult to treat, and both recipients of grafts originating from the same donor are at risk of developing this challenging condition.

  20. A new approach to scoring systems to improve identification of acute medical admissions that will require critical care.

    Science.gov (United States)

    Carmichael, H A; Robertson, E; Austin, J; McCruden, D; Messow, C M; Belcher, P R

    2011-11-01

    Removal of the intensive care unit (ICU) at the Vale of Leven Hospital mandated the identification and transfer out of those acute medical admissions with a high risk of requiring ICU. The aim of the study was to develop triaging tools that identified such patients and compare them with other scoring systems. The methodology included a retrospective analysis of physiological and arterial gas measurements from 1976 acute medical admissions produced PREEMPT-1 (PRE-critical Emergency Medical Patient Triage). A simpler one for ambulance use (PREAMBLE-1 [PRE-Admission Medical Blue-Light Emergency]) was produced by the addition of peripheral oxygen saturation to a modification of MEWS (Modified Early Warning Score). Prospective application of these tools produced a larger database of 4447 acute admissions from which logistic regression models produced PREEMPT-2 and PREAMBLE-2, which were then compared with the original systems and seven other early warning scoring systems. Results showed that in patients with arterial gases, the area under the receiver operator characteristic curve was significantly higher in PREEMPT-2 (89·1%) and PREAMBLE-2 (84.4%) than all other scoring systems. Similarly, in all patients, it was higher in PREAMBLE-2 (92·4%) than PREAMBLE-1 (88·1%) and the other scoring systems. In conclusion, risk of requiring ICU can be more accurately predicted using PREEMPT-2 and PREAMBLE-2, as described here, than by other early warning scoring systems developed over recent years.

  1. Development of a scoring system for differentiating IgG4-related sclerosing cholangitis from primary sclerosing cholangitis.

    Science.gov (United States)

    Moon, Sung-Hoon; Kim, Myung-Hwan; Lee, Jong Kyun; Baek, Seunghee; Woo, Young Sik; Cho, Dong Hui; Oh, Dongwook; Song, Tae Jun; Park, Do Hyun; Lee, Sang Soo; Seo, Dong Wan; Lee, Sung Koo

    2017-04-01

    Recent research has shown that a substantial number of patients with primary sclerosing cholangitis (PSC) can also have elevated serum/tissue IgG4. The aim of our study was to develop a simple scoring system for the discrimination of IgG4-related sclerosing cholangits (IgG4-SC) from PSC. Patients with IgG4-SC (n = 39) and PSC (n = 76) who had intrahepatic/hilar strictures were included. Candidate-differentiating variables included patient age, other organ involvement (OOI), inflammatory bowel disease, serum IgG4, and cholangiographic features. A scoring system was developed on the basis of these variables, and its performance was internally validated using a bootstrapping-based method. The scoring system in the final model included age (IgG4-SC. The discrimination between IgG4-SC and PSC using the scoring system was excellent (area under the receiver operating characteristic curve, 0.986). A reliable differentiation of IgG4-SC from PSC can be made using the scoring system presented here. We suggest the diagnosis of IgG4-SC at a cutoff of 7 points or higher and the indication of diagnostic steroid trial at 5 or 6 points. External validation of our scoring system is warranted.

  2. The predictive validity of grade point average scores in a partial lottery medical school admission system.

    Science.gov (United States)

    Cohen-Schotanus, Janke; Muijtjens, Arno M M; Reinders, Jan J; Agsteribbe, Jessica; van Rossum, Herman J M; van der Vleuten, Cees P M

    2006-10-01

    To ascertain whether the grade point average (GPA) of school-leaving examinations is related to study success, career development and scientific performance. The problem of restriction of range was expected to be partially reduced due to the use of a national lottery system weighted in favour of students with higher GPAs. We studied the students (n = 398) admitted to the Faculty of Medicine, University of Groningen, the Netherlands in 1982 and 1983. Data concerning drop-out and study progress were derived from the student administration. Data about career development were obtained from annual interviews with graduates (n = 318) between 1993 and 2000. Literature searches yielded data concerning scientific performance. Multiple linear regression and logistic regression were used to analyse the data. The variables 'gender' and 'cohort' and their interaction were included in the analyses to account for variation in the general level of the dependent variable and the effect of GPA on the dependent variable. GPA scores had no effect on drop-out rate. High GPA scores were associated with significantly less time to graduation, more chance of a preferred placement for specialist training and higher scientific output. GPA was not related to income. Gender differences were found for study duration and scientific output. Women graduated earlier and published less. The GPA of school-leaving examinations was found to be related to study success, career development and scientific performance. In this study the usual problem of restriction of range was shown to be absent. The weighted lottery procedure even resulted in an over-dispersion of candidates relative to the applicants. The resulting effect sizes were in agreement with those reported in other studies.

  3. Preliminary validation of 2 magnetic resonance image scoring systems for osteoarthritis of the hip according to the OMERACT filter.

    Science.gov (United States)

    Maksymowych, Walter P; Cibere, Jolanda; Loeuille, Damien; Weber, Ulrich; Zubler, Veronika; Roemer, Frank W; Jaremko, Jacob L; Sayre, Eric C; Lambert, Robert G W

    2014-02-01

    Development of a validated magnetic resonance image (MRI) scoring system is essential in hip OA because radiographs are insensitive to change. We assessed the feasibility and reliability of 2 previously developed scoring methods: (1) the Hip Inflammation MRI Scoring System (HIMRISS) and (2) the Hip Osteoarthritis MRI Scoring System (HOAMS). Six readers (3 radiologists, 3 rheumatologists) participated in 2 reading exercises. In Reading Exercise 1, MRI of the hip of 20 subjects were read at a single time point followed by further standardization of methodology. In Reading Exercise 2, MRI of the hip of 18 subjects from a randomized controlled trial, assessed at 2 timepoints, and 27 subjects from a cross-sectional study were read for HIMRISS and HOAMS bone marrow lesions (BML) and synovitis. Reliability was assessed using intraclass correlation coefficient (ICC) and kappa statistics. Both methods were considered feasible. For Reading 1, HIMRISS ICC were 0.52, 0.61, 0.70, and 0.58 for femoral BML, acetabular BML, effusion, and total scores, respectively; and for HOAMS, summed BML and synovitis ICC were 0.52 and 0.46, respectively. For Reading 2, HIMRISS and HOAMS ICC for BML and synovitis-effusion improved substantially. Interobserver reliability for change scores was 0.81 and 0.71 for HIMRISS femoral and HOAMS summed BML, respectively. Responsiveness and discrimination was moderate to high for synovitis-effusion. Significant associations were noted between BML or synovitis scores and Western Ontario and McMaster Universities Osteoarthritis Index pain scores for baseline values (p ≤ 0.001). The BML and synovitis-effusion components of both HIMRISS and HOAMS scoring systems are feasible and reliable, and should be validated further.

  4. A new system for severity scoring of facial fractures: development and validation.

    Science.gov (United States)

    Catapano, Joseph; Fialkov, Jeffrey A; Binhammer, Paul A; McMillan, Catherine; Antonyshyn, Oleh M

    2010-07-01

    Facial fractures are often the result of high-velocity trauma, causing skeletal disruption affecting multiple anatomic sites to varying degrees. Although several widely accepted classification systems exist, these are mostly region-specific and differ in the classification criteria used, making it impossible to uniformly and comprehensively document facial fracture patterns. Furthermore, a widely accepted system that is able to provide a final summary measure of fracture severity does not exist, making it difficult to investigate the epidemiologic data surrounding facial fracture severity. In this study, a comprehensive method for panfacial fracture documentation and severity measurement is proposed and validated through a retrospective analysis of 63 patients operated on for acute facial fracture. The severity scale was validated through statistical analysis of correlation with surrogate markers of severity (operating room procedure time and number of implants). Spearman correlation coefficients were calculated, and a statistically significant correlation was found between severity score and both number of implants and operating room procedure time (R = 0.92790 and R = 0.68157, respectively). Intraclass correlation coefficients were calculated to assess intrarater and interrater reliabilities of the severity scale and were found to be high (0.97 and 0.99, respectively). This severity scale provides a valuable, validated research tool for the investigation of facial fracture severity across patient populations, allowing for systematic evaluation of facial fracture outcomes, cost-benefit analysis, and objective analysis of the effect of specific interventions.

  5. Supraclavicular scalenectomy for thoracic outlet syndrome--functional outcomes assessed using the DASH scoring system.

    LENUS (Irish Health Repository)

    Glynn, Ronan W

    2012-02-01

    To evaluate supraclavicular scalenectomy ± cervical rib excision for thoracic outlet syndrome (TOS), employing Disability of Arm, Shoulder, and Hand (DASH) scoring for functional assessment post-decompression.

  6. Development of a likelihood of survival scoring system for hospitalized equine neonates using generalized boosted regression modeling.

    Directory of Open Access Journals (Sweden)

    Katarzyna A Dembek

    Full Text Available BACKGROUND: Medical management of critically ill equine neonates (foals can be expensive and labor intensive. Predicting the odds of foal survival using clinical information could facilitate the decision-making process for owners and clinicians. Numerous prognostic indicators and mathematical models to predict outcome in foals have been published; however, a validated scoring method to predict survival in sick foals has not been reported. The goal of this study was to develop and validate a scoring system that can be used by clinicians to predict likelihood of survival of equine neonates based on clinical data obtained on admission. METHODS AND RESULTS: Data from 339 hospitalized foals of less than four days of age admitted to three equine hospitals were included to develop the model. Thirty seven variables including historical information, physical examination and laboratory findings were analyzed by generalized boosted regression modeling (GBM to determine which ones would be included in the survival score. Of these, six variables were retained in the final model. The weight for each variable was calculated using a generalized linear model and the probability of survival for each total score was determined. The highest (7 and the lowest (0 scores represented 97% and 3% probability of survival, respectively. Accuracy of this survival score was validated in a prospective study on data from 283 hospitalized foals from the same three hospitals. Sensitivity, specificity, positive and negative predictive values for the survival score in the prospective population were 96%, 71%, 91%, and 85%, respectively. CONCLUSIONS: The survival score developed in our study was validated in a large number of foals with a wide range of diseases and can be easily implemented using data available in most equine hospitals. GBM was a useful tool to develop the survival score. Further evaluations of this scoring system in field conditions are needed.

  7. Development and Validation of the OMERACT Rheumatoid Arthritis Magnetic Resonance Tenosynovitis Scoring System in a Multireader Exercise.

    Science.gov (United States)

    Glinatsi, Daniel; Bird, Paul; Gandjbakhch, Frédérique; Haavardsholm, Espen A; Peterfy, Charles G; Vital, Edward M; Emery, Paul; Conaghan, Philip G; Østergaard, Mikkel

    2017-11-01

    To develop and validate a magnetic resonance imaging (MRI) tenosynovitis (TS) score for tendons at the wrist and metacarpophalangeal (MCP) joint levels in patients with rheumatoid arthritis (RA). Axial T1-weighted precontrast and postcontrast fat-saturated MR image sets of the hands of 43 patients with RA initiating rituximab therapy were obtained at baseline and after 14, 26, 38, or 52 weeks. The MR images were scored twice by 4 readers. Nine tendon compartments of the wrist and 4 flexor tendon compartments at the MCP joints were assessed. Tenosynovitis was scored as follows: 0: No; 1: The overall PEA/PCA intrareader and interreader agreements for change scores in all tendons were 73.8%/97.6% and 47.9%/85.0%, respectively. Average SRM was moderate for total scores and 60.5% of the patients had a tenosynovitis change score ≥ SDC. The TS score showed high intrareader and interreader agreement for wrist and finger tendons, with moderate responsiveness, and the majority of the patients showed a change above the SDC. This scoring system may be included as a component of the RAMRIS.

  8. Comparison of the four proposed Apgar scoring systems in the assessment of birth asphyxia and adverse early neurologic outcomes.

    Directory of Open Access Journals (Sweden)

    Hosein Dalili

    Full Text Available To compare the Conventional, Specified, Expanded and Combined Apgar scoring systems in predicting birth asphyxia and the adverse early neurologic outcomes.This prospective cohort study was conducted on 464 admitted neonates. In the delivery room, after delivery the umbilical cord was double clamped and a blood samples was obtained from the umbilical artery for blood gas analysis, meanwhile on the 1- , 5- and 10- minutes Conventional, Specified, Expanded, and Combined Apgar scores were recorded. Then the neonates were followed and intracranial ultrasound imaging was performed, and the following information were recorded: the occurrence of birth asphyxia, hypoxic Ischemic Encephalopathy (HIE, intraventricular hemorrhage (IVH, and neonatal seizure.The Combined-Apgar score had the highest sensitivity (97% and specificity (99% in predicting birth asphyxia, followed by the Specified-Apgar score that was also highly sensitive (95% and specific (97%. The Expanded-Apgar score was highly specific (95% but not sensitive (67% and the Conventional-Apgar score had the lowest sensitivity (81% and low specificity (81% in predicting birth asphyxia. When adjusted for gestational age, only the low 5-minute Combined-Apgar score was independently associated with the occurrence of HIE (B = 1.61, P = 0.02 and IVH (B = 2.8, P = 0.01.The newly proposed Combined-Apgar score is highly sensitive and specific in predicting birth asphyxia and also is a good predictor of the occurrence of HIE and IVH in asphyxiated neonates.

  9. Validation of risk assessment scoring systems for an audit of elective surgery for gastrointestinal cancer in elderly patients: an audit.

    Science.gov (United States)

    Wakabayashi, Hisao; Sano, Takanori; Yachida, Shinichi; Okano, Keiichi; Izuishi, Kunihiko; Suzuki, Yasuyuki

    2007-10-01

    The goal of this study was to validate the usefulness of risk assessment scoring systems for a surgical audit in elective digestive surgery for elderly patients. The validated scoring systems used were the Physiological and Operative Severity Score for enUmeration of Mortality and morbidity (POSSUM) and the Portsmouth predictor equation for mortality (P-POSSUM). This study involved 153 consecutive patients aged 75 years and older who underwent elective gastric or colorectal surgery between July 2004 and June 2006. A retrospective analysis was performed on data collected prior to each surgery. The predicted mortality and morbidity risks were calculated using each of the scoring systems and were used to obtain the observed/predicted (O/E) mortality and morbidity ratios. New logistic regression equations for morbidity and mortality were then calculated using the scores from the POSSUM system and applied retrospectively. The O/E ratio for morbidity obtained from POSSUM score was 0.23. The O/E ratios for mortality from the POSSUM score and the P-POSSUM were 0.15 and 0.38, respectively. Utilizing the new equations using scores from the POSSUM, the O/E ratio increased to 0.88. Both the POSSUM and P-POSSUM over-predicted the morbidity and mortality in elective gastrointestinal surgery for malignant tumors in elderly patients. However, if a surgical unit makes appropriate calculations using its own patient series and updates these equations, the POSSUM system can be useful in the risk assessment for surgery in elderly patients.

  10. Carpal erosions in children with juvenile idiopathic arthritis: repeatability of a newly devised MR-scoring system

    Energy Technology Data Exchange (ETDEWEB)

    Boavida, Peter [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom); Lambot-Juhan, Karen [Hospital Necker Enfants Malades, Department of Radiology, Paris (France); Ording Mueller, Lil-Sofie [Oslo University Hospital, Department of Radiology, Oslo (Norway); Damasio, Beatrice; Malattia, Clara [Ospedale Pediatrico Gaslini, Department of Rheumatology, Genoa (Italy); Tanturri de Horatio, Laura [Ospedale Pediatrico Bambino Gesu, Department of Radiology, Rome (Italy); Owens, Catherine M. [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom); UCL, Institute of Child Health, London (United Kingdom); Rosendahl, Karen [Haukeland University Hospital, Department of Radiology, Bergen (Norway); University of Bergen, Department of Clinical Medicine, Bergen (Norway)

    2015-12-15

    Juvenile idiopathic arthritis (JIA) is characterized by synovial inflammation, with potential risk of developing progressive joint destruction. Personalized state-of-the-art treatment depends on valid markers for disease activity to monitor response; however, no such markers exist. To evaluate the reliability of scoring of carpal bone erosions on MR in children with JIA using two semi-quantitative scoring systems. A total of 1,236 carpal bones (91 MR wrist examinations) were scored twice by two independent pediatric musculoskeletal radiologists. Bony erosions were scored according to estimated bone volume loss using a 0-4 scale and a 0-10 scale. An aggregate erosion score comprising the sum total carpal bone volume loss was calculated for each examination. The 0-4 scoring system resulted in good intra-reader agreement and moderate to good inter-observer agreement in the assessment of individual bones. Fair and moderate agreement were achieved for inter-reader and intra-reader agreement, respectively, using the 0-10 scale. Intra- and particularly inter-reader aggregate score variability were much less favorable, with wide limits of agreement. Further analysis of erosive disease patterns compared with normal subjects is required, and to facilitate the development of an alternative means of quantifying disease. (orig.)

  11. Carpal erosions in children with juvenile idiopathic arthritis: repeatability of a newly devised MR-scoring system

    International Nuclear Information System (INIS)

    Boavida, Peter; Lambot-Juhan, Karen; Ording Mueller, Lil-Sofie; Damasio, Beatrice; Malattia, Clara; Tanturri de Horatio, Laura; Owens, Catherine M.; Rosendahl, Karen

    2015-01-01

    Juvenile idiopathic arthritis (JIA) is characterized by synovial inflammation, with potential risk of developing progressive joint destruction. Personalized state-of-the-art treatment depends on valid markers for disease activity to monitor response; however, no such markers exist. To evaluate the reliability of scoring of carpal bone erosions on MR in children with JIA using two semi-quantitative scoring systems. A total of 1,236 carpal bones (91 MR wrist examinations) were scored twice by two independent pediatric musculoskeletal radiologists. Bony erosions were scored according to estimated bone volume loss using a 0-4 scale and a 0-10 scale. An aggregate erosion score comprising the sum total carpal bone volume loss was calculated for each examination. The 0-4 scoring system resulted in good intra-reader agreement and moderate to good inter-observer agreement in the assessment of individual bones. Fair and moderate agreement were achieved for inter-reader and intra-reader agreement, respectively, using the 0-10 scale. Intra- and particularly inter-reader aggregate score variability were much less favorable, with wide limits of agreement. Further analysis of erosive disease patterns compared with normal subjects is required, and to facilitate the development of an alternative means of quantifying disease. (orig.)

  12. Evaluating observer agreement of scoring systems for foot integrity and footrot lesions in sheep

    NARCIS (Netherlands)

    Foddai, A.; Green, L.E.; Mason, S.A.; Kaler, J.

    2012-01-01

    Background A scoring scale with five ordinal categories is used for visual diagnosis of footrot in sheep and to study its epidemiology and control. More recently a 4 point ordinal scale has been used by researchers to score foot integrity (wall and sole horn damage) in sheep. There is no information

  13. ReaderBench Learns Dutch: Building a Comprehensive Automated Essay Scoring System for Dutch Language

    NARCIS (Netherlands)

    Dascalu, Mihai; Westera, Wim; Ruseti, Stefan; Trausan-Matu, Stefan; Kurvers, Hub

    2018-01-01

    Automated Essay Scoring has gained a wider applicability and usage with the integration of advanced Natural Language Processing techniques which enabled in-depth analyses of discourse in order capture the specificities of written texts. In this paper, we introduce a novel Automatic Essay Scoring

  14. Meet the donors

    DEFF Research Database (Denmark)

    Olejaz, Maria; Hoeyer, Klaus

    2016-01-01

    motivations, but rather as something made meaningful in the light of how donors understand their bodies; their social relations; and their societal position and experiences as patients in the healthcare system. The article thus contributes to the field by investigating the nature of the relationship between......For centuries, gross anatomy teaching and anatomical dissection have been fundamental elements in the training of medical doctors and surgeons across the world. Anatomy education and research rely on a stable and reliable supply of bodies in order to take place. Based on qualitative in...

  15. A new donor atom system [(SNN)(S)] for the synthesis of neutral oxotechnetium(V) mixed ligand complexes

    International Nuclear Information System (INIS)

    Papadopoulos, M.S.; Pirmettis, I.C.; Spyriounis, D.M.

    1996-01-01

    Oxotechnetium complexes ligated in a 3 + 1 inch fashion yielding TcOL1L2 complexes were prepared. The L1 tridentate ligand binds with a SNN donor set of atoms. L2 corresponds to a monodentate thiol ligand. Representative members of this group of compounds were chemically characterized by NMR and X-ray diffraction

  16. Fermentable carbohydrate dietary consumption measured by a cariogenicity scoring system and caries experience in youth and adults

    OpenAIRE

    Giacaman, Rodrigo A; Fernández, Constanza E; Díaz S, Nora

    2012-01-01

    Aim: To evaluate if dietary fermentable carbohydrate consumption associates with caries experience of youths and adults when assessed by a scoring system of putative cariogenicity of the foods. Methods: Two hundred and seventy five subjects (12 to 67 years-old) were examined to assess caries experience by the DMFT Index (decay missing and filled teeth) and radiographs. Subjects filled a weekly diet diary registering the type, frequency and time of consumption of foods. An arbitrary scoring sy...

  17. New Combined Scoring System for Predicting Respiratory Failure in Iraqi Patients with Guillain-Barré Syndrome

    Directory of Open Access Journals (Sweden)

    Zaki Noah Hasan

    2010-09-01

    Full Text Available The Guillain-Barré syndrome (GBS is an acute post-infective autoimmune polyradiculoneuropathy, it is the commonest peripheral neuropathy causing respiratory failure. The aim of the study is to use the New Combined Scoring System in anticipating respiratory failure in order to perform elective measures without waiting for emergency situations to occur.
    Patients and methods: Fifty patients with GBS were studied. Eight clinical parameters (including progression of patients to maximum weakness, respiratory rate/minute, breath holding
    count (the number of digits the patient can count in holding his breath, presence of facial muscle weakness (unilateral or bilateral, presence of weakness of the bulbar muscle, weakness of the neck flexor muscle, and limbs weakness were assessed for each patient and a certain score was given to
    each parameter, a designed combined score being constructed by taking into consideration all the above mentioned clinical parameters. Results and discussion: Fifteen patients (30% that were enrolled in our study developed respiratory failure. There was a highly significant statistical association between the development of respiratory failure and the lower grades of (bulbar muscle weakness score, breath holding count scores, neck muscle weakness score, lower limbs and upper limbs weakness score , respiratory rate score and the total sum score above 16 out of 30 (p-value=0.000 . No significant statistical difference was found regarding the progression to maximum weakness (p-value=0.675 and facial muscle weakness (p-value=0.482.
    Conclusion: The patients who obtained a combined score (above 16’30 are at great risk of having respiratory failure.

  18. Manual and automatic locomotion scoring systems in dairy cows: a review.

    Science.gov (United States)

    Schlageter-Tello, Andrés; Bokkers, Eddie A M; Koerkamp, Peter W G Groot; Van Hertem, Tom; Viazzi, Stefano; Romanini, Carlos E B; Halachmi, Ilan; Bahr, Claudia; Berckmans, Daniël; Lokhorst, Kees

    2014-09-01

    The objective of this review was to describe, compare and evaluate agreement, reliability, and validity of manual and automatic locomotion scoring systems (MLSSs and ALSSs, respectively) used in dairy cattle lameness research. There are many different types of MLSSs and ALSSs. Twenty-five MLSSs were found in 244 articles. MLSSs use different types of scale (ordinal or continuous) and different gait and posture traits need to be observed. The most used MLSS (used in 28% of the references) is based on asymmetric gait, reluctance to bear weight, and arched back, and is scored on a five-level scale. Fifteen ALSSs were found that could be categorized according to three approaches: (a) the kinetic approach measures forces involved in locomotion, (b) the kinematic approach measures time and distance of variables associated to limb movement and some specific posture variables, and (c) the indirect approach uses behavioural variables or production variables as indicators for impaired locomotion. Agreement and reliability estimates were scarcely reported in articles related to MLSSs. When reported, inappropriate statistical methods such as PABAK and Pearson and Spearman correlation coefficients were commonly used. Some of the most frequently used MLSSs were poorly evaluated for agreement and reliability. Agreement and reliability estimates for the original four-, five- or nine-level MLSS, expressed in percentage of agreement, kappa and weighted kappa, showed large ranges among and sometimes also within articles. After the transformation into a two-level scale, agreement and reliability estimates showed acceptable estimates (percentage of agreement ≥ 75%; kappa and weighted kappa ≥ 0.6), but still estimates showed a large variation between articles. Agreement and reliability estimates for ALSSs were not reported in any article. Several ALSSs use MLSSs as a reference for model calibration and validation. However, varying agreement and reliability estimates of MLSSs make a

  19. Anti-Inflammatory Oxicams as Multi-donor Ligand Systems: pH- and Solvent-Dependent Coordination Modes of Meloxicam and Piroxicam to Ru and Os.

    Science.gov (United States)

    Aman, Farhana; Hanif, Muhammad; Kubanik, Mario; Ashraf, Adnan; Söhnel, Tilo; Jamieson, Stephen M F; Siddiqui, Waseeq Ahmad; Hartinger, Christian G

    2017-04-06

    The nitrogen- and sulfur-containing 1,2-benzothiazines meloxicam and piroxicam are widely used as nonsteroidal anti-inflammatory drugs. Intrigued by the presence of multiple donor atoms and therefore potentially rich coordination chemistry, we prepared a series of organometallic Ru and Os compounds with meloxicam and piroxicam featuring either as mono- or bidentate ligand systems. The choice of the solvent and the pH value was identified as the critical parameter to achieve selectively mono- or bidentate coordination. The coordination modes were confirmed experimentally by NMR spectroscopy and single crystal X-ray diffraction analysis. Using DFT calculations, it was established that complexes in which meloxicam acts as a bidentate N,O donor are energetically more favorable than coordination as O,O and S,O donor systems. Since meloxicam and piroxicam derivatives have shown anticancer activity in the past, we aimed to compare the complexes with mono- and bidentate ligands on their in vitro anticancer activity. However, stability studies revealed that only the latter complexes were stable in [D 6 ]DMSO/D 2 O (5:95) and therefore no direct comparisons could be made. The meloxicam complexes 1 and 2 showed moderate cytotoxicity, whereas the piroxicam derivatives 5 and 6 were hardly active against the utilized cell lines. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. A prospective observational study comparing a physiological scoring system with time-based discharge criteria in pediatric ambulatory surgical patients.

    Science.gov (United States)

    Armstrong, James; Forrest, Helen; Crawford, Mark W

    2015-10-01

    Discharge criteria based on physiological scoring systems can be used in the postanesthesia care unit (PACU) to fast-track patients after ambulatory surgery; however, studies comparing physiological scoring systems with traditional time-based discharge criteria are lacking. The purpose of this study was to compare PACU discharge readiness times using physiological vs time-based discharge criteria in pediatric ambulatory surgical patients. We recorded physiological observations from consecutive American Society of Anesthesiologists physical status I-III patients aged 1-18 yr who were admitted to the PACU after undergoing ambulatory surgery in a tertiary academic pediatric hospital. The physiological score was a combination of the Aldrete and Chung systems. Scores were recorded every 15 min starting upon arrival in the PACU. Patients were considered fit for discharge once they attained a score ≥12 (maximum score, 14), provided no score was zero, with the time to achieve a score ≥12 defining the criteria-based discharge (CBD) time. Patients were discharged from the PACU when both the CBD and the existing time-based discharge (TBD) criteria were met. The CBD and TBD data were compared using Kaplan-Meier and log-rank analysis. Observations from 506 children are presented. Median (interquartile range [IQR]) age was 5.5 [2.8-9.9] yr. Median [IQR] CBD and TBD PACU discharge readiness times were 30 [15-45] min and 60 [45-60] min, respectively. Analysis of Kaplan-Meier curves indicated a significant difference in discharge times using the different criteria (hazard ratio, 5.43; 95% confidence interval, 4.51 to 6.53; P < 0.001). All patients were discharged home without incident. This prospective study suggests that discharge decisions based on physiological criteria have the potential for significantly speeding the transit of children through the PACU, thereby enhancing PACU efficiency and resource utilization.

  1. Imaging diagnostics in ovarian cancer: magnetic resonance imaging and a scoring system guiding choice of primary treatment.

    Science.gov (United States)

    Kasper, Sigrid M; Dueholm, Margit; Marinovskij, Edvard; Blaakær, Jan

    2017-03-01

    To analyze the ability of magnetic resonance imaging (MRI) and systematic evaluation at surgery to predict optimal cytoreduction in primary advanced ovarian cancer and to develop a preoperative scoring system for cancer staging. Preoperative MRI and standard laparotomy were performed in 99 women with either ovarian or primary peritoneal cancer. Using univariate and multivariate logistic regression analysis of a systematic description of the tumor in nine abdominal compartments obtained by MRI and during surgery plus clinical parameters, a scoring system was designed that predicted non-optimal cytoreduction. Non-optimal cytoreduction at operation was predicted by the following: (A) presence of comorbidities group 3 or 4 (ASA); (B) tumor presence in multiple numbers of different compartments, and (C) numbers of specified sites of organ involvement. The score includes: number of compartments involved (1-9 points), >1 subdiaphragmal location with presence of tumor (1 point); deep organ involvement of liver (1 point), porta hepatis (1 point), spleen (1 point), mesentery/vessel (1 point), cecum/ileocecal (1 point), rectum/vessels (1 point): ASA groups 3 and 4 (2 points). Use of the scoring system based on operative findings gave an area under the curve (AUC) of 91% (85-98%) for patients in whom optimal cytoreduction could not be achieved. The score AUC obtained by MRI was 84% (76-92%), and 43% of non-optimal cytoreduction patients were identified, with only 8% of potentially operable patients being falsely evaluated as suitable for non-optimal cytoreduction at the most optimal cut-off value. Tumor in individual locations did not predict operability. This systematic scoring system based on operative findings and MRI may predict non-optimal cytoreduction. MRI is able to assess ovarian cancer with peritoneal carcinomatosis with satisfactory concordance with laparotomic findings. This scoring system could be useful as a clinical guideline and should be evaluated and

  2. Long-term human immune system reconstitution in non-obese diabetic (NOD)-Rag (-)-γ chain (-) (NRG) mice is similar but not identical to the original stem cell donor.

    Science.gov (United States)

    Harris, D T; Badowski, M; Balamurugan, A; Yang, O O

    2013-12-01

    The murine immune system is not necessarily identical to it human counterpart, which has led to the construction of humanized mice. The current study analysed whether or not a human immune system contained within the non-obese diabetic (NOD)-Rag1(null) -γ chain(null) (NRG) mouse model was an accurate representation of the original stem cell donor and if multiple mice constructed from the same donor were similar to one another. To that end, lightly irradiated NRG mice were injected intrahepatically on day 1 of life with purified cord blood-derived CD34(+) stem and progenitor cells. Multiple mice were constructed from each cord blood donor. Mice were analysed quarterly for changes in the immune system, and followed for periods up to 12 months post-transplant. Mice from the same donor were compared directly with each other as well as with the original donor. Analyses were performed for immune reconstitution, including flow cytometry, T cell receptor (TCR) and B cell receptor (BCR) spectratyping. It was observed that NRG mice could be 'humanized' long-term using cord blood stem cells, and that animals constructed from the same cord blood donor were nearly identical to one another, but quite different from the original stem cell donor immune system. © 2013 British Society for Immunology.

  3. Predictors of arrhythmia recurrence after balloon cryoablation of atrial fibrillation: the value of CAAP-AF risk scoring system.

    Science.gov (United States)

    Sanhoury, Mohamed; Moltrasio, Massimo; Tundo, Fabrizio; Riva, Stefania; Dello Russo, Antonio; Casella, Michela; Tondo, Claudio; Fassini, Gaetano

    2017-08-01

    In the present study, we aimed to test the value of CAAP-AF score for prediction of atrial fibrillation (AF) recurrence at follow-up in a group of our patients treated by balloon cryoablation. A total of 283 symptomatic drug-refractory AF patients [261 (92%) with paroxysmal AF] who underwent pulmonary vein isolation (PVI) with second-generation cryoballoon between April 2012 and October 2016 were included. The CAAP-AF score was calculated for every patient. A total of 283 patients [68 female (20%), mean age 59.8 ± 11.4 years] were included in the present analysis. Eighty-nine patients (31%) had hypertension and 13 (4%) had coronary artery disease. The mean left atrial diameter and left ventricular ejection fraction were 40.6 ± 7.0 mm and 60.0 ± 9.1%, respectively. The mean CHA 2 DS 2 -VASc score was 1.2 ± 1.1, and mean number of prior failed antiarrhythmic drugs was 1.4 ± 0.8. At 18 ± 6 months follow-up, 25 patients (8.87%) developed AF recurrence. The recurrence rate was as follows: 3.17% (score 0-3), 8.47% (score 4), 16.28% (score 5), 6.67% (score 6), 23.08% (score 7), and 36.36% (score ≥8). The recurrence rate was 4.86% at a score value ≥5; a score cutoff ≥5 predicted AF recurrence with a sensitivity 64% and specificity 68%. The present analysis suggests the usefulness of CAAP-AF scoring system, with its simple and easily obtained six clinical variables, to predict AF recurrence after PVI by means of second-generation cryoballoon. A score value ≥5 predicted AF recurrence with a sensitivity 64% and specificity 68%.

  4. Predictive value of semi-quantitative MRI-based scoring systems for future knee replacement: data from the osteoarthritis initiative

    International Nuclear Information System (INIS)

    Hafezi-Nejad, Nima; Eng, John; Demehri, Shadpour; Zikria, Bashir; Carrino, John A.

    2015-01-01

    To evaluate, in a confirmatory fashion, whether baseline and change from baseline to 24-month follow-up in cartilage damage, bone marrow lesions and meniscal damage are predictors of knee replacement (KR) in subjects with a high risk of osteoarthritis (OA), independent of the level of physical activity, symptom severity and radiographic abnormalities. Data from the Osteoarthritis Initiative's (OAI) baseline and 24-month follow-up knee MRIs of 115 patients (age range: 45-78 years; 48 % female; BMI: 20.9-48.7) were analyzed. Cartilage, bone marrow and menisci were semi-quantitatively scored according to the Whole-Organ Magnetic Resonance Imaging Score (WORMS) and Boston-Leeds Osteoarthritis Knee Score (BLOKS) systems in all compartments. Baseline and 24-month interval changes in structural tissue damage assessed by BLOKS and WORMS were used as predictors of KR independent of clinical and radiographic parameters using Cox hazard analysis. Adjustments were performed for age, gender, BMI and physical activity (Physical Activity Scale for the Elderly: PASE), Western Ontario and McMaster Questionnaire (WOMAC) total score and radiographic Kellgren-Lawrence (KL) score. BLOKS and WORMS baseline cartilage scores were predictors of KR independent of the PASE, WOMAC and KL score. One score increase in the average baseline BLOKS full-thickness cartilage defect score was associated with a [hazard ratio (95 % CI)] 13.55 (3.61-50.89) times greater risk of KR independent of the PASE, WOMAC and KL score. Net reclassification improvements (NRIs) of the additional evaluation of 24-month follow-up MRI scores and assessment of changes were not significant for prediction of KR (NRI range: - 7.23 - 24.8 %). The BLOKS cartilage score for full-thickness cartilage defects had the highest hazard for KR. Follow-up MRI changes in structural tissue damage, detected by BLOKS and WORMS cartilage, bone marrow or meniscus scores (up to 24 months) had no significant predictive value in addition

  5. Predictive value of semi-quantitative MRI-based scoring systems for future knee replacement: data from the osteoarthritis initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hafezi-Nejad, Nima; Eng, John; Demehri, Shadpour [Johns Hopkins University School of Medicine, Musculoskeletal Radiology, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Zikria, Bashir [Johns Hopkins University, Department of Orthopedic Surgery, Baltimore, MD (United States); Carrino, John A. [Hospital for Special Surgery, Department of Radiology and Imaging, New York, NY (United States)

    2015-11-15

    To evaluate, in a confirmatory fashion, whether baseline and change from baseline to 24-month follow-up in cartilage damage, bone marrow lesions and meniscal damage are predictors of knee replacement (KR) in subjects with a high risk of osteoarthritis (OA), independent of the level of physical activity, symptom severity and radiographic abnormalities. Data from the Osteoarthritis Initiative's (OAI) baseline and 24-month follow-up knee MRIs of 115 patients (age range: 45-78 years; 48 % female; BMI: 20.9-48.7) were analyzed. Cartilage, bone marrow and menisci were semi-quantitatively scored according to the Whole-Organ Magnetic Resonance Imaging Score (WORMS) and Boston-Leeds Osteoarthritis Knee Score (BLOKS) systems in all compartments. Baseline and 24-month interval changes in structural tissue damage assessed by BLOKS and WORMS were used as predictors of KR independent of clinical and radiographic parameters using Cox hazard analysis. Adjustments were performed for age, gender, BMI and physical activity (Physical Activity Scale for the Elderly: PASE), Western Ontario and McMaster Questionnaire (WOMAC) total score and radiographic Kellgren-Lawrence (KL) score. BLOKS and WORMS baseline cartilage scores were predictors of KR independent of the PASE, WOMAC and KL score. One score increase in the average baseline BLOKS full-thickness cartilage defect score was associated with a [hazard ratio (95 % CI)] 13.55 (3.61-50.89) times greater risk of KR independent of the PASE, WOMAC and KL score. Net reclassification improvements (NRIs) of the additional evaluation of 24-month follow-up MRI scores and assessment of changes were not significant for prediction of KR (NRI range: - 7.23 - 24.8 %). The BLOKS cartilage score for full-thickness cartilage defects had the highest hazard for KR. Follow-up MRI changes in structural tissue damage, detected by BLOKS and WORMS cartilage, bone marrow or meniscus scores (up to 24 months) had no significant predictive value in addition

  6. Colon cancer with unresectable synchronous metastases: the AAAP scoring system for predicting the outcome after primary tumour resection.

    Science.gov (United States)

    Li, Z M; Peng, Y F; Du, C Z; Gu, J

    2016-03-01

    The aim of this study was to develop a prognostic scoring system to predict the outcome of patients with unresectable metastatic colon cancer who received primary colon tumour resection. Patients with confirmed metastatic colon cancer treated at the Peking University Cancer Hospital between 2003 and 2012 were reviewed retrospectively. The correlation of clinicopathological factors with overall survival was analysed using the Kaplan-Meier method and the log-rank test. Independent prognostic factors were identified using a Cox proportional hazards regression model and were then combined to form a prognostic scoring system. A total of 110 eligible patients were included in the study. The median survival time was 10.4 months and the 2-year overall survival (OS) rate was 21.8%. Age over 70 years, an alkaline phosphatase (ALP) level over 160 IU/l, ascites, a platelet/lymphocyte ratio (PLR) above 162 and no postoperative therapy were independently associated with a shorter OS in multivariate analysis. Age, ALP, ascites and PLR were subsequently combined to form the so-called AAAP scoring system. Patients were classified into high, medium and low risk groups according to the score obtained. There were significant differences in OS between each group (P colonic cancer who underwent primary tumour resection. The AAAP scoring system may be a useful tool for surgical decision making. Colorectal Disease © 2015 The Association of Coloproctology of Great Britain and Ireland.

  7. Risk stratification in cardiovascular disease primary prevention - scoring systems, novel markers, and imaging techniques.

    LENUS (Irish Health Repository)

    Zannad, Faiez

    2012-04-01

    The aim of this paper is to review and discuss current methods of risk stratification for cardiovascular disease (CVD) prevention, emerging biomarkers, and imaging techniques, and their relative merits and limitations. This report is based on discussions that took place among experts in the area during a special CardioVascular Clinical Trialists workshop organized by the European Society of Cardiology Working Group on Cardiovascular Pharmacology and Drug Therapy in September 2009. Classical risk factors such as blood pressure and low-density lipoprotein cholesterol levels remain the cornerstone of risk estimation in primary prevention but their use as a guide to management is limited by several factors: (i) thresholds for drug treatment vary with the available evidence for cost-effectiveness and benefit-to-risk ratios; (ii) assessment may be imprecise; (iii) residual risk may remain, even with effective control of dyslipidemia and hypertension. Novel measures include C-reactive protein, lipoprotein-associated phospholipase A(2) , genetic markers, and markers of subclinical organ damage, for which there are varying levels of evidence. High-resolution ultrasound and magnetic resonance imaging to assess carotid atherosclerotic lesions have potential but require further validation, standardization, and proof of clinical usefulness in the general population. In conclusion, classical risk scoring systems are available and inexpensive but have a number of limitations. Novel risk markers and imaging techniques may have a place in drug development and clinical trial design. However, their additional value above and beyond classical risk factors has yet to be determined for risk-guided therapy in CVD prevention.

  8. Analysis of Low Appropriateness Score Exam Trends in Decision Support-based Radiology Order Entry System.

    Science.gov (United States)

    Gupta, Supriya; Klein, Kandace; Singh, Anand H; Thrall, James H

    2017-05-01

    Awareness of imaging utilization increased after implementation of Radiology Order Entry with decision support systems (ROE-DS). Our hypothesis is few exams with low Clinical Appropriateness Score (CAS) on ROE-DS are performed. Clinical indications of exams with CAS less than 3 (9-point scale) were re-reviewed and reports analyzed. Structured Query Language-based query retrieved exams with CAS less than 3 in ROE-DS from January 2007 to December 2011. Reasons provided by physicians for ordering these exams and reports of exams performed were analyzed. For each indication, number of exams ordered and performed was calculated. Statistical significance was assessed using Student's t test and χ 2 analysis (P < .05). From 445,984 exams, 12,615 exams (2.8%) had CAS less than 3, and 7,956 exams (63%) were performed. Reasons for ordering of 12,615 low CAS exams were as follows: Requests by physician specialists without further explanation (4,516 = 35.8%), notation of special clinical circumstances (2,877 = 22.8%), requests by nonphysician staff without further explanation (1,383 = 10.9%), absence of suspected finding on previous modality (1,099 = 8.7%), patient preference (737 = 5.8%), and requests based on radiologists' recommendations (706 = 5.6%). Difference between male and female (male < female) preferences for low CAS exams was statistically significant (P < .01). Imaging outcome was highest for extremity MRI cases (66.7%; P < .01). Less than 3% of exams ordered had low CAS and about two-thirds of these were performed. Most common indication for ordering these exams was physician specialist request based on opinion of medical necessity without specification. Extremity MRI constituted the highest positive findings for low CAS exams performed. Published by Elsevier Inc.

  9. Comparison of L-system applications towards plant modelling, music rendering and score generation using visual language programming

    Science.gov (United States)

    Lim, Chen Kim; Tan, Kian Lam; Yusran, Hazwanni; Suppramaniam, Vicknesh

    2017-10-01

    Visual language or visual representation has been used in the past few years in order to express the knowledge in graphic. One of the important graphical elements is fractal and L-Systems is a mathematic-based grammatical model for modelling cell development and plant topology. From the plant model, L-Systems can be interpreted as music sound and score. In this paper, LSound which is a Visual Language Programming (VLP) framework has been developed to model plant to music sound and generate music score and vice versa. The objectives of this research has three folds: (i) To expand the grammar dictionary of L-Systems music based on visual programming, (ii) To design and produce a user-friendly and icon based visual language framework typically for L-Systems musical score generation which helps the basic learners in musical field and (iii) To generate music score from plant models and vice versa using L-Systems method. This research undergoes a four phases methodology where the plant is first modelled, then the music is interpreted, followed by the output of music sound through MIDI and finally score is generated. LSound is technically compared to other existing applications in the aspects of the capability of modelling the plant, rendering the music and generating the sound. It has been found that LSound is a flexible framework in which the plant can be easily altered through arrow-based programming and the music score can be altered through the music symbols and notes. This work encourages non-experts to understand L-Systems and music hand-in-hand.

  10. Prospective comparison of three risk scoring systems in non-variceal and variceal upper gastrointestinal bleeding.

    Science.gov (United States)

    Thanapirom, Kessarin; Ridtitid, Wiriyaporn; Rerknimitr, Rungsun; Thungsuk, Rattikorn; Noophun, Phadet; Wongjitrat, Chatchawan; Luangjaru, Somchai; Vedkijkul, Padet; Lertkupinit, Comson; Poonsab, Swangphong; Ratanachu-ek, Thawee; Hansomburana, Piyathida; Pornthisarn, Bubpha; Thongbai, Thirada; Mahachai, Varocha; Treeprasertsuk, Sombat

    2016-04-01

    Data regarding the efficacy of the Glasgow Blatchford score (GBS), full Rockall score (FRS) and pre-endoscopic Rockall scores (PRS) in comparing non-variceal and variceal upper gastrointestinal bleeding (UGIB) are limited. Our aim was to determine the performance of these three risk scores in predicting the need for treatment, mortality, and re-bleeding among patients with non-variceal and variceal UGIB. During January, 2010 and September, 2011, patients with UGIB from 11 hospitals were prospectively enrolled. The GBS, FRS, and PRS were calculated. Discriminative ability for each score was assessed using the receiver operated characteristics curve (ROC) analysis. A total of 981 patients presented with acute UGIB, 225 patients (22.9%) had variceal UGIB. The areas under the ROC (AUC) of the GBS, FRS, and PRS for predicting the need for treatment were 0.77, 0.69, and 0.61 in non-variceal versus 0.66, 0.66, and 0.59 in variceal UGIB. The AUC for predicting mortality and re-bleeding during admission were 0.66, 0.80, and 0.76 in non-variceal versus 0.63, 0.57, and 0.63 in variceal UGIB. AUC score was not statistically significant for predicting need for therapy and clinical outcome in variceal UGIB. The GBS ≤ 2 and FRS ≤ 1 identified low-risk non-variceal UGIB patients for death and re-bleeding during hospitalization. In contrast to non-variceal UGIB, the GBS, FRS, and PRS were not precise scores for assessing the need for therapy, mortality, and re-bleeding during admission in variceal UGIB. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  11. High-Temperature Short-Time Pasteurization System for Donor Milk in a Human Milk Bank Setting

    OpenAIRE

    Diana Escuder-Vieco; Irene Espinosa-Martos; Juan M. Rodríguez; Nieves Corzo; Antonia Montilla; Pablo Siegfried; Carmen R. Pallás-Alonso; Carmen R. Pallás-Alonso; Leónides Fernández

    2018-01-01

    Donor milk is the best alternative for the feeding of preterm newborns when mother's own milk is unavailable. For safety reasons, it is usually pasteurized by the Holder method (62.5°C for 30 min). Holder pasteurization results in a microbiological safe product but impairs the activity of many biologically active compounds such as immunoglobulins, enzymes, cytokines, growth factors, hormones or oxidative stress markers. High-temperature short-time (HTST) pasteurization has been proposed as an...

  12. Nonradiative inter- and intramolecular energy transfer from the aromatic donor anisole to a synthesized photoswitchable acceptor system.

    Science.gov (United States)

    Bardhan, Munmun; Bhattacharya, Sudeshna; Misra, Tapas; Mukhopadhyay, Rupa; De, Asish; Chowdhury, Joydeep; Ganguly, Tapan

    2010-02-01

    We report steady state and time resolved fluorescence measurements on acetonitrile (ACN) solutions of the model compounds, energy donor anisole (A) and a photoswitchable acceptor N,N'-1,2-phenylene di-p-tosylamide (B) and the multichromophore (M) where A and B are connected by a spacer containing both rigid triple (acetylenic) and flexible methylene bonds. Both steady state and time correlated single photon counting measurements demonstrate that though intermolecular energy transfer, of Forster type, between the donor and acceptor moieties occurs with rate 10(8)s(-1) but when these two reacting components are linked by a spacer (multichromophore, M) the observed transfer rate ( approximately 10(11)s(-1)) enhances. This seemingly indicates that the imposition of the spacer by inserting a triple bond may facilitate in the propagation of electronic excitation energy through bond. The time resolved fluorescence measurements along with the theoretical predictions using Configuration interaction singles (CIS) method by using 6-31G (d,p) basis set, implemented in the Gaussian package indicate the formations of the two excited conformers of B. The experimental findings made from the steady state and time resolved fluorescence measurements demonstrate that, though two different isomeric species of the acceptor B are formed in the excited singlet states, the prevailing singlet-singlet nonradiative energy transfer route was found from the donor A to the relatively longer-lived isomeric species of B. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  13. A simple weighted scoring system to guide surgical decision-making in patients with parapneumonic pleural effusion.

    Science.gov (United States)

    Chang, Che-Chia; Chen, Tzu-Ping; Yeh, Chi-Hsiao; Huang, Pin-Fu; Wang, Yao-Chang; Yin, Shun-Ying

    2016-11-01

    The selection of ideal candidates for surgical intervention among patients with parapneumonic pleural effusion remains challenging. In this retrospective study, we sought to identify the main predictors of surgical treatment and devise a simple scoring system to guide surgical decision-making. Between 2005 and 2014, we identified 276 patients with parapneumonic pleural effusion. Patients in the training set (n=201) were divided into two groups according to their treatment modality (non-surgery vs. surgery). Using multivariable logistic regression analysis, we devised a scoring system to guide surgical decision-making. The score was subsequently validated in an independent set of 75 patients. A white blood cell count >13,500/µL, pleuritic pain, loculations, and split pleura sign were identified as independent predictors of surgical treatment. A weighted score based on these factors was devised, as follows: white blood cell count >13,500/µL (one point), pleuritic pain (one point), loculations (two points), and split pleura sign (three points). A score >4 was associated with a surgical approach with a sensitivity of 93.4%, a specificity of 82.4%, and an area under curve (AUC) of 0.879 (95% confidence interval: 0.828-0.930). In the validation set, a sensitivity of 94.3% and a specificity of 79.6% were found (AUC=0.869). The proposed scoring system reliably identifies patients with parapneumonic pleural effusion who are candidates for surgery. Pending independent external validation, our score may inform the appropriate use of surgical interventions in this clinical setting.

  14. Screening applicants for risk of poor academic performance: a novel scoring system using preadmission grade point averages and graduate record examination scores.

    Science.gov (United States)

    Luce, David

    2011-01-01

    The purpose of this study was to develop an effective screening tool for identifying physician assistant (PA) program applicants at highest risk for poor academic performance. Prior to reviewing applications for the class of 2009, a retrospective analysis of preadmission data took place for the classes of 2006, 2007, and 2008. A single composite score was calculated for each student who matriculated (number of subjects, N=228) incorporating the total undergraduate grade point average (UGPA), the science GPA (SGPA), and the three component Graduate Record Examination (GRE) scores: verbal (GRE-V), quantitative (GRE-Q), analytical (GRE-A). Individual applicant scores for each of the five parameters were ranked in descending quintiles. Each applicant's five quintile scores were then added, yielding a total quintile score ranging from 25, which indicated an excellent performance, to 5, which indicated poorer performance. Thirteen of the 228 students had academic difficulty (dismissal, suspension, or one-quarter on academic warning or probation). Twelve of the 13 students having academic difficulty had a preadmission total quintile score 12 (range, 6-14). In response to this descriptive analysis, when selecting applicants for the class of 2009, the admissions committee used the total quintile score for screening applicants for interviews. Analysis of correlations in preadmission, graduate, and postgraduate performance data for the classes of 2009-2013 will continue and may help identify those applicants at risk for academic difficulty. Establishing a threshold total quintile score of applicant GPA and GRE scores may significantly decrease the number of entering PA students at risk for poor academic performance.

  15. The Importance of Rockall Scoring System for Upper Gastrointestinal Bleeding in Long-Term Follow-Up.

    Science.gov (United States)

    Bozkurt, Mehmet Abdussamet; Peker, Kıvanç Derya; Unsal, Mustafa Gökhan; Yırgın, Hakan; Kahraman, İzzettin; Alış, Halil

    2017-06-01

    The aim of the study is to examine the importance of Rockall scoring system in long-term setting to estimate re-bleeding and mortality rate due to upper gastrointestinal bleeding. A total of 321 patients who had been treated for upper gastrointestinal bleeding were recruited to the study. Patients' demographic and clinical data, the amount of blood transfusion, endoscopy results, and Rockall scores were retrieved from patients' charts. The re-bleeding, morbidity, and mortality rates were noted after 3 years of follow-up with telephone. Re-bleeding rate was statistically significantly higher in Rockall 4 group compared to Rockall 0 group. Mortality rate was also statistically significantly higher in Rockall 4 group. Rockall risk scoring system is a valuable tool to predict re-bleeding and mortality rates for patients with upper gastrointestinal bleeding in long-term setting.

  16. Digital Three-Dimensional Automation of the Modified Huddart and Bodenham Scoring System for Patients With Cleft Lip and Palate.

    Science.gov (United States)

    Ma, Xinhui; Martin, Catherine; McIntyre, Grant; Lin, Ping; Mossey, Peter

    2017-07-01

    The modified Huddart and Bodenham scoring system assesses maxillary arch constriction and surgical outcomes in cleft lip and palate. This project automates modified Huddart and Bodenham scoring using three-dimensional digital models. Development of a novel software tool. The design, construction, development, and testing of the system was carried out at Dundee Dental Hospital. Subjects with cleft lip and palate. A plug-in has been developed using an open three-dimensional development platform: Rhinoceros, version 5 ( http://www.rhino3d.co.uk ). Users select cusps on mandibular and maxillary teeth on three-dimensional digital models. A three-dimensional cubic spline generates a mandibular curve, and a best-fit horizontal mandibular reference plane is produced using a least-squares method. Horizontal distances projected from the shortest three-dimensional distances were subsequently calculated between the maxillary cusps and the mandibular curve to calculate the modified Huddart and Bodenham score. Automatic scoring of digital models using the modified Huddart and Bodenham system produces similar results to manual scoring. By standardizing outcome assessment in cleft care, multicenter comparisons for audit and research can be simplified, allowing centers throughout the world to upload three-dimensional digital models or intraoral scans of the dental arches for remote scoring. Thereafter, these data can feed back into the global database on orofacial clefting as part of the World Health Organization's international collaborative "Global Burden of Disease" research project for craniofacial anomalies. The automated system facilitates quicker and more reliable outcome assessments by minimizing human errors.

  17. The Novel Scoring System for 30-Day Mortality in Patients with Non-variceal Upper Gastrointestinal Bleeding.

    Science.gov (United States)

    Hwang, Sejin; Jeon, Seong Woo; Kwon, Joong Goo; Lee, Dong Wook; Ha, Chang Yoon; Cho, Kwang Bum; Jang, ByungIk; Park, Jung Bae; Park, Youn Sun

    2016-07-01

    Although the mortality rates for non-variceal upper gastrointestinal bleeding (NVUGIB) have recently decreased, it remains a significant medical problem. The main aim of this prospective multicenter database study was to construct a clinically useful predictive scoring system by using our predictors and compare its prognostic accuracy with that of the Rockall scoring system. Data were collected from consecutive patients with NVUGIB. Logistic regression analysis was performed to identify the independent predictors of 30-day mortality. Each independent predictor was assigned an integral point proportional to the odds ratio (OR) and we used the area under the curve to compare the discrimination ability between the new predictive model and the Rockall score. The independent predictors of mortality included age >65 years [OR 2.627; 95 % confidence interval (CI) 1.298-5.318], hemodynamic instability (OR 2.217; 95 % CI 1.069-4.597), serum blood urea nitrogen level >40 mg/dL (OR 1.895; 95 % CI 1.029-3.490), active bleeding at endoscopy (OR 2.434; 95 % CI 1.283-4.616), transfusions (OR 3.811; 95 % CI 1.640-8.857), comorbidities (OR 3.481; 95 % CI 1.405-8.624), and rebleeding (OR 10.581; 95 % CI 5.590-20.030). The new predictive model showed a high discrimination capability and was significantly superior to the Rockall score in predicting the risk of death (OR 0.837;95 % CI 0.818-0.855 vs. 0.761; 0.739-0.782; P = 0.0123). The new predictive score was significantly more accurate than the Rockall score in predicting death in NVUGIB patients. We need to prospectively validate the accuracy of this score for predicting mortality in NVUGIB patients.

  18. Effect of a Publicly Accessible Disclosure System on Food Safety Inspection Scores in Retail and Food Service Establishments.

    Science.gov (United States)

    Choi, Jihee; Scharff, Robert L

    2017-07-01

    The increased frequency with which people are dining out coupled with an increase in the publicity of foodborne disease outbreaks has led the public to an increased awareness of food safety issues associated with food service establishments. To accommodate consumer needs, local health departments have increasingly publicized food establishments' health inspection scores. The objective of this study was to estimate the effect of the color-coded inspection score disclosure system in place since 2006 in Columbus, OH, by controlling for several confounding factors. This study incorporated cross-sectional time series data from food safety inspections performed from the Columbus Public Health Department. An ordinary least squares regression was used to assess the effect of the new inspection regime. The introduction of the new color-coded food safety inspection disclosure system increased inspection scores for all types of establishments and for most types of inspections, although significant differences were found in the degree of improvement. Overall, scores increased significantly by 1.14 points (of 100 possible). An exception to the positive results was found for inspections in response to foodborne disease complaints. Scores for these inspections declined significantly by 10.2 points. These results should be useful for both food safety researchers and public health decision makers.

  19. A cross-sectional study of the Birmingham Vasculitis Activity Score version 3 in systemic vasculitis

    NARCIS (Netherlands)

    Suppiah, Ravi; Mukhtyar, Chetan; Flossmann, Oliver; Alberici, Federico; Baslund, Bo; Batra, Rajbir; Brown, Denise; Holle, Julia; Hruskova, Zdenka; Jayne, David R. W.; Judge, Andrew; Little, Mark A.; Palmisano, Alessandra; Stegeman, Coen; Tesar, Vladimir; Vaglio, Augusto; Westman, Kerstin; Luqmani, Raashid

    Methods. A total of 238 patients with vasculitis from seven countries in Europe were evaluated at a single time point. Spearman's correlation coefficients were calculated between BVAS v. 3 scores, vasculitis activity index (VAI), physician's global assessment (PGA), the physician's treatment

  20. Crosscultural Adaptation and Validation of the Korean Version of the New Knee Society Knee Scoring System.

    Science.gov (United States)

    Kim, Seok Jin; Basur, Mohnish Singh; Park, Chang Kyu; Chong, Suri; Kang, Yeon Gwi; Kim, Moon Ju; Jeong, Jeong Seong; Kim, Tae Kyun

    2017-06-01

    The 2011 Knee Society Score © (2011 KS Score © ) is used to characterize the expectations, symptoms, physical activity, and satisfaction of patients who undergo TKA and is widely used to assess the outcome of TKA. However, it has not been adapted or validated for use in Korea. We developed a Korean version of the 2011 KS Score and evaluated the (1) test-retest reliability, (2) convergent validity, and (3) responsiveness of the Korean version. The Korean version of the 2011 KS Score was derived by using a well-established translational procedure based on international guidelines, which include translation, synthesis, back-translation, expert committee review, pretesting, and submission for appraisal. A total of 123 patients with knee osteoarthritis who were scheduled to undergo TKA were recruited for the study. Ninety percent of the patients (111 of 123) were women, which is an exact representation of the Korean population having TKAs. To evaluate reliability, the patients were evaluated twice during a 4-week interval using the questionnaire. Reliability was assessed by using intraclass correlation coefficients (ICCs) and internal consistency by using Cronbach's alpha to determine the validity of the Korean version of the 2011 KS Score. The patients were evaluated by using the validated Korean versions of the WOMAC and SF-36 questionnaires. Spearman's correlation coefficient was used for validation. Responsiveness was determined by calculating the standardized response mean from the preoperative and postoperative test scores in the Korean version of the 2011 KS Score. To address the gender disparity in our study we identified 53 males who underwent TKA for osteoarthritis after completion of this study and generated age-matched controlled groups to evaluate construct validity and responsiveness in Korean males. The reliability proved good to excellent with an ICC between 0.69 and 0.85, depending on the clinical properties tested, which included the following

  1. Analyzing the Factorial Structure of the Classroom Assessment Scoring System-Secondary Using a Bayesian Hierarchical Multivariate Ordinal Model

    Science.gov (United States)

    Yuan, Kun; McCaffrey, Daniel F.; Savitsky, Terrance D.

    2013-01-01

    Standardized teaching observation protocols have become increasingly popular in evaluating teaching in recent years. One of such protocols that has gained substantial interest from researchers and practitioners is the Classroom Assessment Scoring System-Secondary (CLASSS). According to the developer, CLASS-S has three domains of teacher-student…

  2. Assessment of a Chemotherapy Response Score (CRS) System for Tubo-Ovarian High-Grade Serous Carcinoma (HGSC)

    DEFF Research Database (Denmark)

    Ditzel, Helena M; Strickland, Kyle C; Meserve, Emily E

    2018-01-01

    A chemotherapy response score (CRS) system was recently described to assess the histopathologic response and prognosis of patients with tubo-ovarian high-grade serous carcinoma (HGSC) receiving neoadjuvant chemotherapy. The current study was performed as an independent assessment of this CRS syst...

  3. Donor-Derived Myeloid Sarcoma in Two Kidney Transplant Recipients from a Single Donor

    Directory of Open Access Journals (Sweden)

    Amudha Palanisamy

    2015-01-01

    Full Text Available We report the rare occurrence of donor-derived myeloid sarcoma in two kidney transplant patients who received organs from a single deceased donor. There was no evidence of preexisting hematologic malignancy in the donor at the time of organ recovery. Both recipients developed leukemic involvement that appeared to be limited to the transplanted organ. Fluorescence in situ hybridization (FISH and molecular genotyping analyses confirmed that the malignant cells were of donor origin in each patient. Allograft nephrectomy and immediate withdrawal of immunosuppression were performed in both cases; systemic chemotherapy was subsequently administered to one patient. Both recipients were in remission at least one year following the diagnosis of donor-derived myeloid sarcoma. These cases suggest that restoration of the immune system after withdrawal of immunosuppressive therapy and allograft nephrectomy may be sufficient to control HLA-mismatched donor-derived myeloid sarcoma without systemic involvement.

  4. Accuracy and Predictability of PANC-3 Scoring System over APACHE II in Acute Pancreatitis: A Prospective Study.

    Science.gov (United States)

    Rathnakar, Surag Kajoor; Vishnu, Vikram Hubbanageri; Muniyappa, Shridhar; Prasath, Arun

    2017-02-01

    Acute Pancreatitis (AP) is one of the common conditions encountered in the emergency room. The course of the disease ranges from mild form to severe acute form. Most of these episodes are mild and spontaneously subsiding within 3 to 5 days. In contrast, Severe Acute Pancreatitis (SAP) occurring in around 15-20% of all cases, mortality can range between 10 to 85% across various centres and countries. In such a situation we need an indicator which can predict the outcome of an attack, as severe or mild, as early as possible and such an indicator should be sensitive and specific enough to trust upon. PANC-3 scoring is such a scoring system in predicting the outcome of an attack of AP. To assess the accuracy and predictability of PANC-3 scoring system over APACHE II in predicting severity in an attack of AP. This prospective study was conducted on 82 patients admitted with the diagnosis of pancreatitis. Investigations to evaluate PANC-3 and APACHE II were done on all the patients and the PANC-3 and APACHE II score was calculated. PANC-3 score has a sensitivity of 82.6% and specificity of 77.9%, the test had a Positive Predictive Value (PPV) of 0.59 and Negative Predictive Value (NPV) of 0.92. Sensitivity of APACHE II in predicting SAP was 91.3% and specificity was 96.6% with PPV of 0.91, NPV was 0.96. Our study shows that PANC-3 can be used to predict the severity of pancreatitis as efficiently as APACHE II. The interpretation of PANC-3 does not need expertise and can be applied at the time of admission which is an advantage when compared to classical scoring systems.

  5. Evaluation of the Procleix Ultrio Elite Assay and the Panther-System for Individual NAT Screening of Blood, Hematopoietic Stem Cell, Tissue and Organ Donors

    Science.gov (United States)

    Heim, Albert

    2016-01-01

    Summary Background The performance of the multiplex Procleix Ultrio Elite assay as individual donor nucleic acid test (ID-NAT) for the detection of HIV-1, HIV-2, HCV, and HBV was evaluated in a retrospective, single center study. Methods ID-NAT results of 21,181 blood donors, 984 tissue donors, 293 hematopoietic stem cell donors and 4 organ donors were reviewed in synopsis with results of serological screening and additional discriminatory and repetitive NAT in case of positive donors. Results Specificity of the initial Procleix Ultrio Elite assay was 99.98% and after discriminatory testing 100.00%. Initially invalid results were observed in 75 of 21,181 blood donors (0.35%) but 16 of 984 tissue donors (1.62%, p donors. All these had valid negative ID-NAT results after repeated testing or testing of 1:5 diluted specimens in case of tissue donors. Occult hepatitis B (defined here as HBV DNAemia without HBsAg detection) was demonstrated by ID-NAT in two anti-HBc-positive tissue donors and suspected in two other tissue donors, where a definite diagnosis was not achieved due to the insufficient sample volumes available. Conclusion The Procleix Ultrio Elite assay proved to be specific, robust and rapid. Therefore, routine ID-NAT may also be feasible for organ and granulocyte donors. PMID:27403089

  6. Evaluation of the Procleix Ultrio Elite Assay and the Panther-System for Individual NAT Screening of Blood, Hematopoietic Stem Cell, Tissue and Organ Donors.

    Science.gov (United States)

    Heim, Albert

    2016-05-01

    The performance of the multiplex Procleix Ultrio Elite assay as individual donor nucleic acid test (ID-NAT) for the detection of HIV-1, HIV-2, HCV, and HBV was evaluated in a retrospective, single center study. ID-NAT results of 21,181 blood donors, 984 tissue donors, 293 hematopoietic stem cell donors and 4 organ donors were reviewed in synopsis with results of serological screening and additional discriminatory and repetitive NAT in case of positive donors. Specificity of the initial Procleix Ultrio Elite assay was 99.98% and after discriminatory testing 100.00%. Initially invalid results were observed in 75 of 21,181 blood donors (0.35%) but 16 of 984 tissue donors (1.62%, p donors. All these had valid negative ID-NAT results after repeated testing or testing of 1:5 diluted specimens in case of tissue donors. Occult hepatitis B (defined here as HBV DNAemia without HBsAg detection) was demonstrated by ID-NAT in two anti-HBc-positive tissue donors and suspected in two other tissue donors, where a definite diagnosis was not achieved due to the insufficient sample volumes available. The Procleix Ultrio Elite assay proved to be specific, robust and rapid. Therefore, routine ID-NAT may also be feasible for organ and granulocyte donors.

  7. Generation of human induced pluripotent stem cells from urinary cells of a healthy donor using a non-integration system

    OpenAIRE

    Uhm, Kyung-Ok; Jo, Eun Hee; Go, Gue Youn; Kim, So-Jung; Choi, Hye Young; Im, Young Sam; Ha, Hye-Yeong; Jung, Ji-Won; Koo, Soo Kyung

    2017-01-01

    Urinary cells can be an ideal source for generating hiPSCs and progenitors, as they are easily accessible, non-invasive, and universally available. We generated human induced pluripotent stem cells (hiPSCs) from the urinary cells of a healthy donor using a Sendai virus-based gene delivery method. The generated hiPSC line, KSCBi001-A, has a normal karyotype (46,XY). The pluripotency and capacity of multilineage differentiation were characterized by comparison with those of a human embryonic st...

  8. Who to handover: a case-control study of a novel scoring system to prioritise handover of internal medicine inpatients.

    Science.gov (United States)

    Bittman, Jesse; Tam, Penny; Little, Chris; Khan, Nadia

    2017-06-01

    Handover of patients between care providers is a critical event in patient care. There is, however, little evidence to guide the handover process, including determining which patients to handover. Compare the ability of gestalt-based handover with two structured scores, the modified early warning score (MEWS) and our novel iHAND clinical decision support system, to predict which patients will be assessed by a physician overnight. This case-control study included 90 inpatients, comprising 32 patients assessed overnight (cases) and 58 patients not assessed overnight (controls) at a teaching hospital in British Columbia, Canada (May 2012). Gestalt, MEWS and iHAND scores were analysed against patients seen overnight using logistic regression and receiver-operating characteristic (ROC) curves. Neither current gestalt-based handover practice (odds ratio (OR) 1.50, 95% CI 0.89 to 3.83) nor MEWS (OR 0.96, 95% CI 0.75 to 1.24, area under the ROC curve (AUC) 0.61, 95% CI 0.49 to 0.73) were significantly associated with need to be seen overnight. The iHAND score was associated with need to be seen (OR 1.93, 95% CI 1.24 to 3.02, AUC 0.70, 95% CI 0.60 to 0.81). The iHAND score had moderate ability to predict which patients required assessment overnight, while MEWS score and current gestalt approach correlated poorly, suggesting the iHAND score may help prioritisation of patients likely to be seen overnight for handover. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. Efficiency of unenhanced MRI in the diagnosis of acute appendicitis: Comparison with Alvarado scoring system and histopathological results

    International Nuclear Information System (INIS)

    Inci, Ercan; Hocaoglu, Elif; Aydin, Sibel; Palabiyik, Figen; Cimilli, Tan; Turhan, Ahmet Nuray; Ayguen, Ersan

    2011-01-01

    Purpose: The purpose of this study was to assess the diagnostic value of unenhanced magnetic resonance imaging (MRI) in the diagnosis of acute appendicitis and compare with Alvarado scores and histopathological results. Materials and methods: The study included 85 consecutive patients (mean age, 26.5 ± 11.3 years) who were clinically suspected of having acute appendicitis. Each patients Alvarado scores were recorded and unenhanced MRI was performed, consisting of T1-weighted, T2-weighted and fat-suppressed T2-weighted fast spin-echo sequences. The MR images were prospectively reviewed in consensus for the presence of acute appendicitis by two radiologists who were blinded to the results of the Alvarado scores. The study population were divided into three subgroups based on the MRI findings: Group I: definitely not appendicitis, Group II: probably appendicitis, Group III: definitely appendicitis. All patients were divided into two subgroups according to Alvarado scores as Group A (low: 1-6), and Group B (high: 7-10). MR findings were compared with Alvarado scores and histopathological findings. Results: Sixty-six (77.6%) of the 85 patients with clinically suspected acute appendicitis, had undergone surgery. The diagnosis of appendicitis could be correctly achieved with MRI in 55 (83.3%) of 57 (86.4%) patients with histopathologically proven acute appendicitis. The sensitivity, specificity, positive predictive value and negative predictive value of MRI examination and Alvarado scoring system in the diagnosis of acute appendicitis were 96.49%, 66.67%, 94.83%, 75.0% and 84.21%, 66.67%, 94.12%, 40.0%, respectively. Conclusions: MRI is a valuable technique for detecting acute appendicitis even in the cases with low Alvarado scores. To increase the diagnostic accuracy and preventing unnecessary laparotomies for suspected appendicitis, shorter and cheaper unenhanced basic MRI may be performed.

  10. Efficiency of unenhanced MRI in the diagnosis of acute appendicitis: Comparison with Alvarado scoring system and histopathological results

    Energy Technology Data Exchange (ETDEWEB)

    Inci, Ercan, E-mail: ercan_inci@mynet.com [Department of Radiology, Istanbul Bakirkoy Dr. Sadi Konuk Training and Research Hospital, Incirli-Bakirkoy, Istanbul (Turkey); Hocaoglu, Elif; Aydin, Sibel; Palabiyik, Figen; Cimilli, Tan [Department of Radiology, Istanbul Bakirkoy Dr. Sadi Konuk Training and Research Hospital, Incirli-Bakirkoy, Istanbul (Turkey); Turhan, Ahmet Nuray; Ayguen, Ersan [Department of Surgery, Istanbul Bakirkoy Dr. Sadi Konuk Training and Research Hospital, Istanbul (Turkey)

    2011-11-15

    Purpose: The purpose of this study was to assess the diagnostic value of unenhanced magnetic resonance imaging (MRI) in the diagnosis of acute appendicitis and compare with Alvarado scores and histopathological results. Materials and methods: The study included 85 consecutive patients (mean age, 26.5 {+-} 11.3 years) who were clinically suspected of having acute appendicitis. Each patients Alvarado scores were recorded and unenhanced MRI was performed, consisting of T1-weighted, T2-weighted and fat-suppressed T2-weighted fast spin-echo sequences. The MR images were prospectively reviewed in consensus for the presence of acute appendicitis by two radiologists who were blinded to the results of the Alvarado scores. The study population were divided into three subgroups based on the MRI findings: Group I: definitely not appendicitis, Group II: probably appendicitis, Group III: definitely appendicitis. All patients were divided into two subgroups according to Alvarado scores as Group A (low: 1-6), and Group B (high: 7-10). MR findings were compared with Alvarado scores and histopathological findings. Results: Sixty-six (77.6%) of the 85 patients with clinically suspected acute appendicitis, had undergone surgery. The diagnosis of appendicitis could be correctly achieved with MRI in 55 (83.3%) of 57 (86.4%) patients with histopathologically proven acute appendicitis. The sensitivity, specificity, positive predictive value and negative predictive value of MRI examination and Alvarado scoring system in the diagnosis of acute appendicitis were 96.49%, 66.67%, 94.83%, 75.0% and 84.21%, 66.67%, 94.12%, 40.0%, respectively. Conclusions: MRI is a valuable technique for detecting acute appendicitis even in the cases with low Alvarado scores. To increase the diagnostic accuracy and preventing unnecessary laparotomies for suspected appendicitis, shorter and cheaper unenhanced basic MRI may be performed.

  11. How education systems shape cross-national ethnic inequality in math competence scores: Moving beyond mean differences.

    Science.gov (United States)

    Spörlein, Christoph; Schlueter, Elmar

    2018-01-01

    Here we examine a conceptualization of immigrant assimilation that is based on the more general notion that distributional differences erode across generations. We explore this idea by reinvestigating the efficiency-equality trade-off hypothesis, which posits that stratified education systems educate students more efficiently at the cost of increasing inequality in overall levels of competence. In the context of ethnic inequality in math achievement, this study explores the extent to which an education system's characteristics are associated with ethnic inequality in terms of both the group means and group variances in achievement. Based on data from the 2012 PISA and mixed-effect location scale models, our analyses revealed two effects: on average, minority students had lower math scores than majority students, and minority students' scores were more concentrated at the lower end of the distribution. However, the ethnic inequality in the distribution of scores declined across generations. We did not find compelling evidence that stratified education systems increase mean differences in competency between minority and majority students. However, our analyses revealed that in countries with early educational tracking, minority students' math scores tended to cluster at the lower end of the distribution, regardless of compositional and school differences between majority and minority students.

  12. A new Leukemia Prognostic Scoring System for refractory/relapsed adult acute myelogeneous leukaemia patients: a GOELAMS study.

    Science.gov (United States)

    Chevallier, P; Labopin, M; Turlure, P; Prebet, T; Pigneux, A; Hunault, M; Filanovsky, K; Cornillet-Lefebvre, P; Luquet, I; Lode, L; Richebourg, S; Blanchet, O; Gachard, N; Vey, N; Ifrah, N; Milpied, N; Harousseau, J-L; Bene, M-C; Mohty, M; Delaunay, J

    2011-06-01

    A simplified prognostic score is presented based on the multivariate analysis of 138 refractory/relapsed acute myeloid leukaemia (AML) patients (median age 55 years, range: 19-70) receiving a combination of intensive chemotherapy+Gemtuzumab as salvage regimen. Overall, 2-year event-free survival (EFS) and overall survival (OS) were 29±4% and 36±4%, respectively. Disease status (relapse Leukemia Prognostic Scoring System was then validated on an independent cohort of 111 refractory/relapsed AML patients. This new simplified prognostic score, using three clinical and biological parameters routinely applied, allow to discriminate around two third of the patients who should benefit from a salvage intensive regimen in the setting of refractory/relapsed AML patients. The other one third of the patients should receive investigational therapy.

  13. [Does the GHQ-12 scoring system affect its factor structure? An exploratory study of Ibero American students].

    Science.gov (United States)

    Urzúa, Alfonso; Caqueo-Urízar, Alejandra; Bargsted, Mariana; Irarrázaval, Matías

    2015-06-01

    This study aimed to evaluate whether the scoring system of the General Health Questionnaire (GHQ-12) alters the instrument's factor structure. The method considered 1,972 university students from nine Ibero American countries. Modeling was performed with structural equations for 1, 2, and 3 latent factors. The mechanism for scoring the questions was analyzed within each type of structure. The results indicate that models with 2 and 3 factors show better goodness-of-fit. In relation to scoring mechanisms, procedure 0-1-1-1 for models with 2 and 3 factors showed the best fit. In conclusion, there appears to be a relationship between the response format and the number of factors identified in the instrument's structure. The model with the best fit was 3-factor 0-1-1-1-formatted, but 0-1-2-3 has acceptable and more stable indicators and provides a better format for two- and three-dimensional models.

  14. Clinical audit in gynecological cancer surgery: development of a risk scoring system to predict adverse events.

    Science.gov (United States)

    Kondalsamy-Chennakesavan, Srinivas; Bouman, Chantal; De Jong, Suzanne; Sanday, Karen; Nicklin, Jim; Land, Russell; Obermair, Andreas

    2009-12-01

    Advanced gynecological surgery undertaken in a specialized gynecologic oncology unit may be associated with significant perioperative morbidity. Validated risk prediction models are available for general surgical specialties but currently not for gynecological cancer surgery. The objective of this study was to evaluate risk factors for adverse events (AEs) of patients treated for suspected or proven gynecological cancer and to develop a clinical risk score (RS) to predict such AEs. AEs were prospectively recorded and matched with demographical, clinical and histopathological data on 369 patients who had an abdominal or laparoscopic procedure for proven or suspected gynecological cancer at a tertiary gynecological cancer center. Stepwise multiple logistic regression was used to determine the best predictors of AEs. For the risk score (RS), the coefficients from the model were scaled using a factor of 2 and rounded to the nearest integer to derive the risk points. Sum of all the risk points form the RS. Ninety-five patients (25.8%) had at least one AE. Twenty-nine (7.9%) and 77 (20.9%) patients experienced intra- and postoperative AEs respectively with 11 patients (3.0%) experiencing both. The independent predictors for any AE were complexity of the surgical procedure, elevated SGOT (serum glutamic oxaloacetic transaminase, > or /=35 U/L), higher ASA scores and overweight. The risk score can vary from 0 to 14. The risk for developing any AE is described by the formula 100 / (1 + e((3.697 - (RS /2)))). RS allows for quantification of the risk for AEs. Risk factors are generally not modifiable with the possible exception of obesity.

  15. Imperfect implementation of an early warning scoring system in a Danish teaching hospital

    DEFF Research Database (Denmark)

    Niegsch, Mark; Fabritius, Maria Louise; Anhøj, Jacob

    2013-01-01

    In 2007, the initiation of a patient safety campaign led to the introduction of Ward Observational Charts (WOC) and Medical Early Warning Score (MEWS) at Naestved Regional Hospital. This included systematic measuring of vital signs of all patients in order to prevent patient deterioration and ass...... and assure timely and correct initiation of treatment. The aim of this study was to assess to what degree WOC guidelines being followed by ward staff....

  16. The Generic Impact Scoring System (GISS): a standardized tool to quantify the impacts of alien species

    Czech Academy of Sciences Publication Activity Database

    Nentwig, W.; Bacher, S.; Pyšek, Petr; Vila, M.; Kumschick, S.

    2016-01-01

    Roč. 188, č. 5 (2016), s. 1-13, č. článku 315. ISSN 0167-6369 R&D Projects: GA ČR GB14-36079G Grant - others:AV ČR(CZ) AP1002 Program:Akademická prémie - Praemium Academiae Institutional support: RVO:67985939 Keywords : scoring * impact * biological invasions Subject RIV: EH - Ecology, Behaviour Impact factor: 1.687, year: 2016

  17. Scoring Systems for Estimating the Risk of Anticoagulant-Associated Bleeding.

    Science.gov (United States)

    Parks, Anna L; Fang, Margaret C

    2017-07-01

    Anticoagulant medications are frequently used to prevent and treat thromboembolic disease. However, the benefits of anticoagulants must be balanced with a careful assessment of the risk of bleeding complications that can ensue from their use. Several bleeding risk scores are available, including the Outpatient Bleeding Risk Index, HAS-BLED, ATRIA, and HEMORR 2 HAGES risk assessment tools, and can be used to help estimate patients' risk for bleeding on anticoagulants. These tools vary by their individual risk components and in how they define and weigh clinical factors. However, it is not yet clear how best to integrate bleeding risk tools into clinical practice. Current bleeding risk scores generally have modest predictive ability and limited ability to predict the most devastating complication of anticoagulation, intracranial hemorrhage. In clinical practice, bleeding risk tools should be paired with a formal determination of thrombosis risk, as their results may be most influential for patients at the lower end of thrombosis risk, as well as for highlighting potentially modifiable risk factors for bleeding. Use of bleeding risk scores may assist clinicians and patients in making informed and individualized anticoagulation decisions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Different hip and knee priority score systems: are they good for the same thing?

    Science.gov (United States)

    Escobar, Antonio; Quintana, Jose Maria; Espallargues, Mireia; Allepuz, Alejandro; Ibañez, Berta

    2010-10-01

    The aim of the present study was to compare two priority tools used for joint replacement for patients on waiting lists, which use two different methods. Two prioritization tools developed and validated by different methodologies were used on the same cohort of patients. The first, an IRYSS hip and knee priority score (IHKPS) developed by RAND method, was applied while patients were on the waiting list. The other, a Catalonia hip-knee priority score (CHKPS) developed by conjoint analysis, was adapted and applied retrospectively. In addition, all patients fulfilled pre-intervention the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Correlation between them was studied by Pearson correlation coefficient (r). Agreement was analysed by means of intra-class correlation coefficient (ICC), Kendall coefficient and Cohern kappa. The relationship between IHKPS, CHKPS and baseline WOMAC scores by r coefficient was studied. The sample consisted of 774 consecutive patients. Pearson correlation coefficient between IHKPS and CHKPS was 0.79. The agreement study showed that ICC was 0.74, Kendall coefficient 0.86 and kappa 0.66. Finally, correlation between CHKPS and baseline WOMAC ranged from 0.43 to 0.64. The results according to the relationship between IHKPS and WOMAC ranged from 0.50 to 0.74. Results support the hypothesis that if the final objective of the prioritization tools is to organize and sort patients on the waiting list, although they use different methodologies, the results are similar. © 2010 Blackwell Publishing Ltd.

  19. Analysis of Surgical Site Infection after Musculoskeletal Tumor Surgery: Risk Assessment Using a New Scoring System

    Directory of Open Access Journals (Sweden)

    Satoshi Nagano

    2014-01-01

    Full Text Available Surgical site infection (SSI has not been extensively studied in musculoskeletal tumors (MST owing to the rarity of the disease. We analyzed incidence and risk factors of SSI in MST. SSI incidence was evaluated in consecutive 457 MST cases (benign, 310 cases and malignant, 147 cases treated at our institution. A detailed analysis of the clinical background of the patients, pre- and postoperative hematological data, and other factors that might be associated with SSI incidence was performed for malignant MST cases. SSI occurred in 0.32% and 12.2% of benign and malignant MST cases, respectively. The duration of the surgery (P=0.0002 and intraoperative blood loss (P=0.0005 was significantly more in the SSI group than in the non-SSI group. We established the musculoskeletal oncological surgery invasiveness (MOSI index by combining 4 risk factors (blood loss, operation duration, preoperative chemotherapy, and the use of artificial materials. The MOSI index (0–4 points score significantly correlated with the risk of SSI, as demonstrated by an SSI incidence of 38.5% in the group with a high score (3-4 points. The MOSI index score and laboratory data at 1 week after surgery could facilitate risk evaluation and prompt diagnosis of SSI.

  20. Laparoscopic donor nephrectomy

    Directory of Open Access Journals (Sweden)

    Gupta Nitin

    2005-01-01

    Full Text Available Of the various options for patients with end stage renal disease, kidney transplantation is the treatment of choice for a suitable patient. The kidney for transplantation is retrieved from either a cadaver or a live donor. Living donor nephrectomy has been developed as a method to address the shortfall in cadaveric kidneys available for transplantation. Laparoscopic living donor nephrectomy (LLDN, by reducing postoperative pain, shortening convalescence, and improving the cosmetic outcome of the donor nephrectomy, has shown the potential to increase the number of living kidney donations further by removing some of the disincentives inherent to donation itself. The technique of LLDN has undergone evolution at different transplant centers and many modifications have been done to improve donor safety and recipient outcome. Virtually all donors eligible for an open surgical procedure may also undergo the laparoscopic operation. Various earlier contraindications to LDN, such as right donor kidney, multiple vessels, anomalous vasculature and obesity have been overcome with increasing experience. Laparoscopic live donor nephrectomy can be done transperitoneally or retroperitoneally on either side. The approach is most commonly transperitoneal, which allows adequate working space and easy dissection. A review of literature and our experience with regards to standard approach and the modifications is presented including a cost saving model for the developing countries. An assessment has been made, of the impact of LDN on the outcome of donor and the recipient.

  1. An inflammation-based cumulative prognostic score system in patients with diffuse large B cell lymphoma in rituximab era.

    Science.gov (United States)

    Sun, Feifei; Zhu, Jia; Lu, Suying; Zhen, Zijun; Wang, Juan; Huang, Junting; Ding, Zonghui; Zeng, Musheng; Sun, Xiaofei

    2018-01-02

    Systemic inflammatory parameters are associated with poor outcomes in malignant patients. Several inflammation-based cumulative prognostic score systems were established for various solid tumors. However, there is few inflammation based cumulative prognostic score system for patients with diffuse large B cell lymphoma (DLBCL). We retrospectively reviewed 564 adult DLBCL patients who had received rituximab, cyclophosphamide, doxorubicin, vincristine and prednisolone (R-CHOP) therapy between Nov 1 2006 and Dec 30 2013 and assessed the prognostic significance of six systemic inflammatory parameters evaluated in previous studies by univariate and multivariate analysis:C-reactive protein(CRP), albumin levels, the lymphocyte-monocyte ratio (LMR), the neutrophil-lymphocyte ratio(NLR), the platelet-lymphocyte ratio(PLR)and fibrinogen levels. Multivariate analysis identified CRP, albumin levels and the LMR are three independent prognostic parameters for overall survival (OS). Based on these three factors, we constructed a novel inflammation-based cumulative prognostic score (ICPS) system. Four risk groups were formed: group ICPS = 0, ICPS = 1, ICPS = 2 and ICPS = 3. Advanced multivariate analysis indicated that the ICPS model is a prognostic score system independent of International Prognostic Index (IPI) for both progression-free survival (PFS) (p systemic inflammatory status was associated with clinical outcomes of patients with DLBCL in rituximab era. The ICPS model was shown to classify risk groups more accurately than any single inflammatory prognostic parameters. These findings may be useful for identifying candidates for further inflammation-related mechanism research or novel anti-inflammation target therapies.

  2. Validation of a new pediatric joint scoring system from the International Hemophilia Prophylaxis Study Group: validity of the hemophilia joint health score

    NARCIS (Netherlands)

    Feldman, Brian M.; Funk, Sharon M.; Bergstrom, Britt-Marie; Zourikian, Nichan; Hilliard, Pamela; van der Net, Janjaap; Engelbert, Raoul; Petrini, Pia; van den Berg, H. Marijke; Manco-Johnson, Marilyn J.; Rivard, Georges E.; Abad, Audrey; Blanchette, Victor S.

    2011-01-01

    Repeated hemarthrosis in hemophilia causes arthropathy with pain and dysfunction. The Hemophilia Joint Health Score (HJHS) was developed to be more sensitive for detecting arthropathy than the World Federation of Hemophilia (WFH) physical examination scale, especially for children and those using

  3. Scoring system based on electrocardiogram features to predict the type of heart failure in patients with chronic heart failure

    Directory of Open Access Journals (Sweden)

    Hendry Purnasidha Bagaswoto

    2016-12-01

    Full Text Available ABSTRACT Heart failure is divided into heart failure with reduced ejection fraction (HFrEF and heart failure with preserved ejection fraction (HFpEF. Additional studies are required to distinguish between these two types of HF. A previous study showed that HFrEF is less likely when ECG findings are normal. This study aims to create a scoring system based on ECG findings that will predict the type of HF. We performed a cross-sectional study analyzing ECG and echocardiographic data from 110 subjects. HFrEF was defined as an ejection fraction ≤40%. Fifty people were diagnosed with HFpEF and 60 people suffered from HFrEF. Multiple logistic regression analysis revealed certain ECG variables that were independent predictors of HFrEF i.e., LAH, QRS duration >100 ms, RBBB, ST-T segment changes and prolongation of the QT interval. Based on ROC curve analysis, we obtained a score for HFpEF of -1 to +3, while HFrEF had a score of +4 to +6 with 76% sensitivity, 96% specificity, 95% positive predictive value, an 80% negative predictive value and an accuracy of 86%. The scoring system derived from this study, including the presence or absence of LAH, QRS duration >100 ms, RBBB, ST-T segment changes and prolongation of the QT interval can be used to predict the type of HF with satisfactory sensitivity and specificity

  4. Inter- and intra-observer variability associated with the use of the Mirels' scoring system for metastatic bone lesions.

    LENUS (Irish Health Repository)

    Mac Niocaill, Ruairi F

    2011-01-01

    Metastatic bone disease is increasing in association with ever-improving medical management of osteophylic malignant conditions. The precise timing of surgical intervention for secondary lesions in long bones can be difficult to determine. This paper aims to evaluate a classic scoring system. All radiographs were examined twice by three orthopaedic oncologists and scored according to the Mirels\\' scoring system. The Kappa statistic was used for the purpose of statistical analysis. The results show agreement between observers (κ = 0.35-0.61) for overall scores at the two time intervals. Inter-observer agreement was also seen with subset analysis of size (κ = 0.27-0.60), site (κ = 0.77-1.0) and nature of the lesion (κ = 0.55-0.81). Similarly, low levels of intra-observer variability were noted for each of the three surgeons (κ= 0.34, 0.39, and 0.78, respectively). These results indicate a reliable, repeatable assessment of bony metastases. We continue to advocate its use in the management of patients with long bone metastases.

  5. The OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging (MRI) Scoring System: Updated Recommendations by the OMERACT MRI in Arthritis Working Group.

    Science.gov (United States)

    Østergaard, Mikkel; Peterfy, Charles G; Bird, Paul; Gandjbakhch, Frédérique; Glinatsi, Daniel; Eshed, Iris; Haavardsholm, Espen A; Lillegraven, Siri; Bøyesen, Pernille; Ejbjerg, Bo; Foltz, Violaine; Emery, Paul; Genant, Harry K; Conaghan, Philip G

    2017-11-01

    The Outcome Measures in Rheumatology (OMERACT) Rheumatoid Arthritis (RA) Magnetic Resonance Imaging (MRI) scoring system (RAMRIS), evaluating bone erosion, bone marrow edema/osteitis, and synovitis, was introduced in 2002, and is now the standard method of objectively quantifying inflammation and damage by MRI in RA trials. The objective of this paper was to identify subsequent advances and based on them, to provide updated recommendations for the RAMRIS. MRI studies relevant for RAMRIS and technical and scientific advances were analyzed by the OMERACT MRI in Arthritis Working Group, which used these data to provide updated considerations on image acquisition, RAMRIS definitions, and scoring systems for the original and new RA pathologies. Further, a research agenda was outlined. Since 2002, longitudinal studies and clinical trials have documented RAMRIS variables to have face, construct, and criterion validity; high reliability and sensitivity to change; and the ability to discriminate between therapies. This has enabled RAMRIS to demonstrate inhibition of structural damage progression with fewer patients and shorter followup times than has been possible with conventional radiography. Technical improvements, including higher field strengths and improved pulse sequences, allow higher image resolution and contrast-to-noise ratio. These have facilitated development and validation of scoring methods of new pathologies: joint space narrowing and tenosynovitis. These have high reproducibility and moderate sensitivity to change, and can be added to RAMRIS. Combined scores of inflammation or joint damage may increase sensitivity to change and discriminative power. However, this requires further research. Updated 2016 RAMRIS recommendations and a research agenda were developed.

  6. Growth performance, carcass yield and gait score of Marshal broiler chicken reared on intensive and semi intensive management systems

    Directory of Open Access Journals (Sweden)

    Oluwadiya, B. O.

    2017-06-01

    Full Text Available The rearing system used in highly productive farms is often subjected to harsh criticism, one of the reasons being its failure to provide adequate welfare. A number of attempts have been made to introduce new technologies in rearing poultry for meat production aiming at improving rearing conditions, protecting the environment and enhancing the quality of poultry products. Given the above, one hundred and sixty eight unsexed 14-day old Marshall broiler chicks were used in a completely randomized design study to compare the effect of management systems (intensive and semi intensive on the growth performance, carcass characteristics and gait score of broiler chickens. The experiment lasted for 42 d. Data were collected on weight gain, feed intake, feed conversion ratio, carcass yield and gait score. Result showed that birds on the intensive management system recorded higher weight gain (P 0.05; 66.94%, 11.44% than those in semi-intensive system (54.55%, 10.92%, respectively. For the gait score broiler birds on semi intensive management system recorded reduced number of cases of severe and slight leg problems (P < 0.05, 25.76% vs 49.3%. It was concluded that broiler birds should be reared on intensive management system for better growth performance and carcass yield. However, birds reared on semi intensive management system had fewer leg problems compared to birds reared on intensive management system. The fewer severe leg problems observed in birds on semi intensive management system will help improve their market value thereby making birds more profitable to rear on semi intensive management system.

  7. Distinguishing infected from noninfected abdominal fluid collections after surgery: an imaging, clinical, and laboratory-based scoring system.

    Science.gov (United States)

    Gnannt, Ralph; Fischer, Michael A; Baechler, Thomas; Clavien, Pierre-Alain; Karlo, Christoph; Seifert, Burkhardt; Lesurtel, Mickael; Alkadhi, Hatem

    2015-01-01

    Mortality from abdominal abscesses ranges from 30% in treated cases up to 80% to 100% in patients with undrained or nonoperated abscesses. Various computed tomographic (CT) imaging features have been suggested to indicate infection of postoperative abdominal fluid collections; however, features are nonspecific and substantial overlap between infected and noninfected collections exists. The purpose of this study was to develop and validate a scoring system on the basis of CT imaging findings as well as laboratory and clinical parameters for distinguishing infected from noninfected abdominal fluid collections after surgery. The score developmental cohort included 100 consecutive patients (69 men, 31 women; mean age, 58 ± 17 years) who underwent portal-venous phase CT within 24 hours before CT-guided intervention of postoperative abdominal fluid collections. Imaging features included attenuation (Hounsfield unit [HU]), volume, wall enhancement and thickness, fat stranding, as well as entrapped gas of fluid collections. Laboratory and clinical parameters included diabetes, intake of immunosuppressive drugs, body temperature, C-reactive protein, and leukocyte blood cell count. The score was validated in a separate cohort of 30 consecutive patients (17 men, 13 women; mean age, 51 ± 15 years) with postoperative abdominal fluid collections. Microbiologic analysis from fluid samples served as the standard of reference. Diabetes, body temperature, C-reactive protein, attenuation of the fluid collection (in HUs), wall enhancement and thickness of the wall, adjacent fat stranding, as well as entrapped gas within the fluid collection were significantly different between infected and noninfected collections (P collection (in HUs), as well as entrapped gas as significant independent predictors of infection (P collection, ≥ 20 HU: 4 points; entrapped gas: 3 points). The model was well calibrated (Hosmer-Lemeshow test, P = 0.36). In the validation cohort, scores of 2 or lower

  8. Evaluation of clinical features scoring system as screening tool for influenza A (H1N1 in epidemic situations

    Directory of Open Access Journals (Sweden)

    P Ranjan

    2012-01-01

    Full Text Available Background: Influenza A (H1N1 hit the headlines in recent times and created mass hysteria and general panic. The high cost and non-availability of diagnostic laboratory tests for swine flu, especially in the developing countries underlines the need of having a cheaper, easily available, yet reasonably accurate screening test. Aims: This study was carried out to develop a clinical feature-based scoring system (CFSS for influenza A (H1N1 and to evaluate its suitability as a screening tool when large numbers of influenza-like illness cases are suspect. Settings and Design: Clinical-record based study, carried out retrospectively in post-pandemic period on subject′s case-sheets who had been quarantined at IG International Airport′s quarantine center at Delhi. Materials and Methods: Clinical scoring of each suspected case was done by studying their case record sheet and compared with the results of RT-PCR. RT-PCR was used to confirm the diagnosis (Gold Standard. Statistical Analysis: We calculated sensitivity, specificity, positive and negative predictive values of the clinical feature-based scoring system (the proposed new screening tool at different cut-off values. The most discriminant cut-off value was determined by plotting the ROC curve. Results: Of the 638 suspected cases, 127 (20% were confirmed to have H1N1 by RT-PCR examination. On the basis of ROC, the most discriminant clinical feature score for diagnosing Influenza A was found to be 7, which yielded sensitivity, specificity, positive, and negative predictive values of 86%, 88%, 64%, and 96%, respectively. Conclusion: The clinical features scoring system (CFSS can be used as a valid and cost-effective tool for screening swine flu (influenza A (H1N1 cases from large number of influenza-like illness suspects.

  9. Brasfield and Wisconsin scoring systems have equal value as outcome assessment tools of cystic fibrosis lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Cleveland, Robert H.; Stamoulis, Catherine; Sawicki, Gregory; Kelliher, Emma; Wood, Christopher; Zurakowski, David; Lee, Edward [Boston Children' s Hospital, Harvard Medical School, Department of Radiology, Boston, MA (United States); Zucker, Evan J. [Tufts Medical School, Boston, MA (United States)

    2014-05-15

    Several imaging-based scoring systems have been used as outcome measures in assessing the severity of cystic fibrosis (CF) lung disease. It has been shown that chest radiography performs equally to computed tomography (CT). There is the opinion that of the two most commonly used chest radiograph (CXR) systems, the Brasfield system is less sensitive and reliable than the Wisconsin system. This report assesses the reproducibility and reliability of the two systems. Thirty patients with CXRs during a 5-year period were randomly selected. One hundred eighty-two studies had data for all CXRs and pulmonary function tests (PFTs), Forced Expiratory Volume in One Second (FEV-1) and Forced Vital Capacity (FVC). PFT values closest to the date of each CXR were recorded. Four radiologists scored each image twice by both the Brasfield and Wisconsin systems. Intra- and inter-rater reliability, correlation with PFTs and direct correlation of the two systems were calculated. Intra-rater agreement: r = 0.86-0.99 Brasfield, r = 0.78-0.96 Wisconsin. Inter-rater agreement: 0.76-0.90 Brasfield, r = 0.74-0.97 Wisconsin. Brasfield vs. FEV-1: r = 0.55, vs. FVC r = 0.61. Wisconsin vs. FEV-1: r = 0.57, vs. FVC r = 0.66. Correlation of the two systems: r = 0.86 (all P < 0.001). The Brasfield and Wisconsin systems performed very similarly providing equally reproducible, robust and reliable measures. (orig.)

  10. End points for validating early warning scores in the context of rapid response systems

    DEFF Research Database (Denmark)

    Pedersen, N. E.; Oestergaard, D.; Lippert, A.

    2016-01-01

    with optimal treatment. This could pose a limitation to studies using these end points. We studied current expert opinion on end points for validating tools for the identification of patients in hospital wards at risk of imminent critical illness. METHODS: The Delphi consensus methodology was used. We......INTRODUCTION: When investigating early warning scores and similar physiology-based risk stratification tools, death, cardiac arrest and intensive care unit admission are traditionally used as end points. A large proportion of the patients identified by these end points cannot be saved, even...

  11. Primary graft dysfunction; possible evaluation by high resolution computed tomography, and suggestions for a scoring system

    DEFF Research Database (Denmark)

    Belmaati, Esther; Jensen, Claus; Kofoed, Klaus F

    2009-01-01

    /exclusion criteria of patients, pilot testing, and training investigators through review of disagreements, were possibilities suggested for decreasing inter/intra observer variability. Factors affecting the image attenuation (Hounsfield numbers) and thus, the reproducibility of CT densitometric measurements were...... of parenchymal change in the lung. HRCT is considered relevant and superior in evaluating disease severity, disease progression, and in evaluating the effects of therapy regimes in the lung. It is, however, not clear to what extent these scoring methods may be implemented for grading PGD. Further efforts could...

  12. High resolution computed tomography of the chest in cystic fibrosis (CF): is simplification of scoring systems feasible?

    Energy Technology Data Exchange (ETDEWEB)

    Oikonomou, Anastasia; Prassopoulos, Panos [University Hospital of Alexandroupolis, Democritus University of Thrace, Department of Radiology, Dragana, Alexandroupolis (Greece); Tsanakas, John; Hatziagorou, Elpis; Kirvassilis, Fotios [Ippokratio Hospital of Thessaloniki, Aristotle University of Thessaloniki, 3d Department of Pediatrics, Thessaloniki (Greece); Efremidis, Stavros [University Hospital of Ioannina, University of Ioannina, Department of Radiology, Ioannina (Greece)

    2008-03-15

    The purpose of this study was to simplify HRCT scoring systems (SS) for CF by selecting representative HRCT parameters. Forty-two consecutive patients with CF underwent baseline and follow-up chest HRCT. Three radiologists evaluated 84 HRCTs employing five SS. ''Simplified'' HRCT SS were formed by selection of parameters exhibiting statistically significant relations with FEV1. Pulmonary function tests (PFTs) and nutrition (IBW%) were recorded. Regression analysis, Pearson correlation and T-test were used for statistical analysis. Three HRCT parameters were selected for the formation of ''simplified'' HRCT SS (severity of bronchiectasis, bronchial wall thickening, atelectasis-consolidation) using regression analysis. There was excellent correlation between each ''simplified'' and corresponding complete score (0.892 < r < 0.0967, p < 0.0001) or the remaining four complete scores (0.786 < r < 0.961, p < 0.0001). Strong correlation was found among the five ''simplified'' scores (0.803 < r < 0.997, p < 0.0001). Comparing baseline complete and ''simplified'' scores with corresponding follow-up ones, significant worsening was observed (p < 0.0001). PFTs and IBW% did not change significantly. HRCT scores correlated moderately with FVC and FEV1, but there was no correlation with FEF25-75 and IBW%. ''Simplified'' HRCT SS are as reliable as the complete ones and detect progression of lung disease earlier than clinical parameters. They are easy to use and could be adopted in clinical practice. (orig.)

  13. NIKEI: a new inexpensive and non-invasive scoring system to exclude advanced fibrosis in patients with NAFLD.

    Directory of Open Access Journals (Sweden)

    Münevver Demir

    Full Text Available AIMS: To develop, validate and compare a non-invasive fibrosis scoring system for non-alcoholic fatty liver disease (NAFLD derived from routinely obtained clinical and biochemical parameters. METHODS: 267 consecutive patients with biopsy proven fatty liver or non-alcoholic steatohepatitis were randomly assigned to the estimation (2/3 or validation (1/3 group to develop a model for the prediction of advanced fibrosis. Univariate statistics were performed to compare patients with and without advanced fibrosis, and following a multivariate logistic regression analysis a new scoring system was constructed. This non-invasive Koeln-Essen-index (NIKEI was validated and compared to the FIB-4 index by calculating the area under the receiver operating characteristic curve (AUC. We evaluated a stepwise combination of both scoring systems for the precise prediction of advanced fibrosis. To set in contrast, we additionally tested the diagnostic accuracy of the AST/ALT ratio, BARD score and the NAFLD fibrosis score in our cohort. RESULTS: Age, AST, AST/ALT ratio, and total bilirubin were identified as significant predictors of advanced fibrosis and used to construct the NIKEI with an AUC of 0.968 [0.937; 0.998] compared to 0.929 [0.869; 0.989] for the FIB-4 index. The absence of advanced fibrosis could be confirmed with excellent accuracy (99-100%. The positive predictive value of the FIB-4 index was higher (100% vs. 60%, however, the false negative rate was also high (33%. With a stepwise combination of both indices 82%-84% of biopsies would have been avoidable without a single misclassification. The AUROC for AST/ALT ratio, the NAFLD fibrosis score, and the BARD score were 0.81 (95% CI, 0.72-0.90, 0.96 (95% CI 0.92-0.99, and 0.67 (95% CI 0.55-0.78, respectively. CONCLUSION: The NIKEI can reliably exclude advanced fibrosis in subjects with NAFLD. In combination with the FIB-4 index misclassification with inadequate clinical management can be avoided while

  14. Computer Algorithms in the Search for Unrelated Stem Cell Donors

    Directory of Open Access Journals (Sweden)

    David Steiner

    2012-01-01

    Full Text Available Hematopoietic stem cell transplantation (HSCT is a medical procedure in the field of hematology and oncology, most often performed for patients with certain cancers of the blood or bone marrow. A lot of patients have no suitable HLA-matched donor within their family, so physicians must activate a “donor search process” by interacting with national and international donor registries who will search their databases for adult unrelated donors or cord blood units (CBU. Information and communication technologies play a key role in the donor search process in donor registries both nationally and internationaly. One of the major challenges for donor registry computer systems is the development of a reliable search algorithm. This work discusses the top-down design of such algorithms and current practice. Based on our experience with systems used by several stem cell donor registries, we highlight typical pitfalls in the implementation of an algorithm and underlying data structure.

  15. An Automatic Assessment System of Diabetic Foot Ulcers Based on Wound Area Determination, Color Segmentation, and Healing Score Evaluation.

    Science.gov (United States)

    Wang, Lei; Pedersen, Peder C; Strong, Diane M; Tulu, Bengisu; Agu, Emmanuel; Ignotz, Ron; He, Qian

    2015-08-07

    For individuals with type 2 diabetes, foot ulcers represent a significant health issue. The aim of this study is to design and evaluate a wound assessment system to help wound clinics assess patients with foot ulcers in a way that complements their current visual examination and manual measurements of their foot ulcers. The physical components of the system consist of an image capture box, a smartphone for wound image capture and a laptop for analyzing the wound image. The wound image assessment algorithms calculate the overall wound area, color segmented wound areas, and a healing score, to provide a quantitative assessment of the wound healing status both for a single wound image and comparisons of subsequent images to an initial wound image. The system was evaluated by assessing foot ulcers for 12 patients in the Wound Clinic at University of Massachusetts Medical School. As performance measures, the Matthews correlation coefficient (MCC) value for the wound area determination algorithm tested on 32 foot ulcer images was .68. The clinical validity of our healing score algorithm relative to the experienced clinicians was measured by Krippendorff's alpha coefficient (KAC) and ranged from .42 to .81. Our system provides a promising real-time method for wound assessment based on image analysis. Clinical comparisons indicate that the optimized mean-shift-based algorithm is well suited for wound area determination. Clinical evaluation of our healing score algorithm shows its potential to provide clinicians with a quantitative method for evaluating wound healing status. © 2015 Diabetes Technology Society.

  16. Alternative Techniques for Cannulation of Biliary Strictures Resistant to the 0.035 System Following Living Donor Liver Transplantation

    International Nuclear Information System (INIS)

    Yoon, Hee Mang; Kim, Jin Hyoung; Ko, Gi Young; Song, Ho Young; Gwon, Dong Il; Sung, Kyu Bo

    2012-01-01

    To assess the clinical efficacy of alternative techniques for biliary stricture cannulation in patients undergoing living donor liver transplantation (LDLT), after cannulation failure with a conventional (0.035-inch guidewire) technique. Of 293 patients with biliary strictures after LDLT, 19 (6%) patients, 11 men and 8 women of mean age 48.5 years, had the failed cannulation of the stricture by conventional techniques. Recannulation was attempted by using two alternative methods, namely a micro-catheter set via percutaneous access and a snare (rendezvous) technique using percutaneous and endoscopic approaches. Strictures were successfully cannulated in 16 (84%) of the 19 patients. A microcatheter set was used in 12 and a snare technique in four patients. Stricture cannulation failed in the remaining three patients, who finally underwent surgical revision. Most technical failures using a conventional technique for biliary stricture cannulation after LDLT can be overcome by using a microcatheter set or a snare (rendezvous) technique.

  17. Alternative Techniques for Cannulation of Biliary Strictures Resistant to the 0.035 System Following Living Donor Liver Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hee Mang; Kim, Jin Hyoung; Ko, Gi Young; Song, Ho Young; Gwon, Dong Il; Sung, Kyu Bo [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2012-03-15

    To assess the clinical efficacy of alternative techniques for biliary stricture cannulation in patients undergoing living donor liver transplantation (LDLT), after cannulation failure with a conventional (0.035-inch guidewire) technique. Of 293 patients with biliary strictures after LDLT, 19 (6%) patients, 11 men and 8 women of mean age 48.5 years, had the failed cannulation of the stricture by conventional techniques. Recannulation was attempted by using two alternative methods, namely a micro-catheter set via percutaneous access and a snare (rendezvous) technique using percutaneous and endoscopic approaches. Strictures were successfully cannulated in 16 (84%) of the 19 patients. A microcatheter set was used in 12 and a snare technique in four patients. Stricture cannulation failed in the remaining three patients, who finally underwent surgical revision. Most technical failures using a conventional technique for biliary stricture cannulation after LDLT can be overcome by using a microcatheter set or a snare (rendezvous) technique.

  18. Generation of human induced pluripotent stem cells from urinary cells of a healthy donor using a non-integration system.

    Science.gov (United States)

    Uhm, Kyung-Ok; Jo, Eun Hee; Go, Gue Youn; Kim, So-Jung; Choi, Hye Young; Im, Young Sam; Ha, Hye-Yeong; Jung, Ji-Won; Koo, Soo Kyung

    2017-05-01

    Urinary cells can be an ideal source for generating hiPSCs and progenitors, as they are easily accessible, non-invasive, and universally available. We generated human induced pluripotent stem cells (hiPSCs) from the urinary cells of a healthy donor using a Sendai virus-based gene delivery method. The generated hiPSC line, KSCBi001-A, has a normal karyotype (46,XY). The pluripotency and capacity of multilineage differentiation were characterized by comparison with those of a human embryonic stem cell line. This cell line is registered and available from National Stem Cell Bank, Korea National Institute of Health. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Donor Telomere Length SAA

    Science.gov (United States)

    A new NCI study has found that, among patients with severe aplastic anemia who received a hematopoietic cell transplant from an unrelated donor, those whose donor white blood cells had longer telomeres had higher survival rates five-years after transplant

  20. Tokuhashi Scoring System has limited applicability in the majority of patients with spinal cord compression secondary to vertebral metastasis

    Directory of Open Access Journals (Sweden)

    Matheus Fernandes de Oliveira

    2013-10-01

    Full Text Available Spine is the primary bone site affected by systemic metastasis. Although there are scales that attempt to manage these patients, their real applicability is unknown. The Tokuhashi Scoring System (TSS is a widely used prognostic tool. At the time of treatment, the data necessary to complete TSS may be incomplete, making its application impossible. Objective To evaluate the number of TSS scores completed by the time the clinical therapeutic decision was made. Methods From July 2010 to January 2012, we selected patients who were diagnosed with spinal metastases. Results Sixty spinal metastasis patients (21 female, 39 male were evaluated between July 2010 and January 2012. At the time of the treatment decision, only 25% of the patients had completed the TSS items. Conclusion In the majority of patients with vertebral metastasis, TSS variables cannot be applied.

  1. Organ donors: deceased or alive? Quo vadis?

    Science.gov (United States)

    Rozental, R

    2006-01-01

    Irrespectively of universal shortage of donor organs there is a tendency of increasing the number of transplantations from living and deceased donors. Each of these two methods has positive and negative features. The main obstacles using living donors are health hazard, necessity to solve certain donor's social and psychological problems, possibility of organ trade and moving. The main problems connected with organ retrieval from deceased donors are possible conflicts with public opinion: difficulties in interpretation of brain death, legislation, obtaining of informed consent from donor's relatives, etc. Future progress in organ transplantation may take place through activation of organ retrieval from deceased donors. The most perspective ways are change to presumed consent in all countries, establishing of centralized system of donor detection and registration, intensification of transplant coordination, active contacts with mass-media, etc. It is necessary to increase (enhance) participation of the members of the public in organ donation process, to develop solidarity among the public members and to involve public authorities to deal with this problem. Bioethical standards should be put in accordance with common progress and some ethical traditions should be changed.

  2. APACHE II SCORING SYSTEM AND ITS MODIFICATION FOR THE ASSESSMENT OF DISEASE SEVERITY IN CHILDREN WHO UNDERWENT POLYCHEMOTHERAPY

    Directory of Open Access Journals (Sweden)

    А. V. Sotnikov

    2014-01-01

    Full Text Available Short-term disease prognosis should be considered for the appropriate treatment policy based on the assessment of disease severity in patients with acute disease. The adequate assessment of disease severity and prognosis allows the indications for transferring patients to the resuscitation and intensive care department to be defined more precisely. Disease severity of patients who underwent polychemotherapy was assessed using APACHE II scoring system.

  3. Multimodal Biometric System- Fusion Of Face And Fingerprint Biometrics At Match Score Fusion Level

    OpenAIRE

    Grace Wangari Mwaura; Prof. Waweru Mwangi; Dr. Calvins Otieno

    2017-01-01

    Biometrics has developed to be one of the most relevant technologies used in Information Technology IT security. Unimodal biometric systems have a variety of problems which decreases the performance and accuracy of these system. One way to overcome the limitations of the unimodal biometric systems is through fusion to form a multimodal biometric system. Generally biometric fusion is defined as the use of multiple types of biometric data or ways of processing the data to improve the performanc...

  4. Assessment of a credit scoring system for popular bank savings and credit

    Directory of Open Access Journals (Sweden)

    José Francisco Martínez Sánchez

    2016-01-01

    Full Text Available El sistema bancario actual no cubre las necesidades de servicios financieros, y en particular de créditos, a los sectores más desfavorecidos de la sociedad. La presencia bancaria se localiza fundamentalmente en las ciudades y regiones con actividad económica importante, y para atender a estos sectores excluidos se han creado de forma natural, pero sin supervisión ni soporte de la autoridad, entidades financieras como las cajas populares, cooperativas, sociedades financieras populares, entre otras, que en conjunto se denominan entidades de ahorro y crédito popular. Sin embargo, la mayoría de este tipo de instituciones no son reconocidas ni supervisadas por la CNBV, lo cual se traduce en riesgos tanto para los usuarios de los servicios como para las instituciones financieras, destacando las ineficiencias en sus procesos de otorgamiento de créditos, ya que las decisiones de aceptar o no una solicitud de crédito se sustentan en el conocimiento, la experiencia y el criterio del analista de crédito. Este trabajo presenta la evaluación de un sistema de credit scoring , tanto en términos de costo-eficiencia para las entidades de ahorro y crédito, en especial para las SOFIPOS, como en términos de costo-beneficio para el proveedor de los servicios de evaluación de solicitudes de crédito. Como se mostrará en el desarrollo del trabajo, un modelo de esta naturaleza hace más eficiente el proceso crediticio a un costo razonable y es una inversión rentable para el proveedor de servicios de credit scoring.

  5. Comparison of pain scores between patients undergoing panretinal photocoagulation using navigated or pattern scan laser systems

    Directory of Open Access Journals (Sweden)

    Umit Ubeyt Inan

    2016-02-01

    Full Text Available ABSTRACT Purpose: To compare the pain responses of patients with proliferative diabetic retinopathy (PDR undergoing panretinal photocoagulation (PRP using either pattern scan laser (PASCAL or navigated laser photocoagulation (NAVILAS. Methods: Patients diagnosed with PDR were randomly assigned to undergo either PASCAL or NAVILAS photocoagulation treatment. PRP was performed using the multi-shot mode with a spot size of 200-400 µm and a pulse duration of 30 ms to obtain a white-grayish spot on the retina. Parameters were identical in both procedures. After 30 min of PRP application, patients were asked to verbally describe their pain perception as either "none," "mild," "moderate," "severe," or "very severe" using a verbal rating scale (VRS and visual analog scale (VAS by indicating a score from "0" to "10," representing the severity of pain from "no pain" to "severe pain." Results: A total of 60 eyes of 60 patients (20 females and 40 males diagnosed with PDR were treated. The mean age of patients was 62.22 ± 9.19 years, and the mean diabetes duration was 195.47 ± 94.54 months. The mean number of laser spots delivered during PRP was 389.47 ± 71.52 in the NAVILAS group and 392.70 ± 54.33 in the PASCAL group (p=0.57. The difference in pain responses between patients in the NAVILAS and PASCAL groups was significant with regard to the mean VRS (1.10 ± 0.67 and 1.47 ± 0.69, respectively; p=0.042 and mean VAS (2.13 ± 1.17 and 2.97 ± 1.35, respectively; p=0.034 scores. Conclusions: Pain responses in patients undergoing PRP with a 30-ms pulse duration were significantly milder in the NAVILAS group than in the PASCAL group.

  6. On chirality transfer in electron donor-acceptor complexes. A prediction for the sulfinimine···BF3 system.

    Science.gov (United States)

    Rode, Joanna E; Dobrowolski, Jan Cz

    2012-01-01

    Stabilization energies of the electron donor-acceptor sulfinimine···BF(3) complexes calculated at either the B3LYP/aug-cc-pVTZ or the MP2/aug-cc-pVTZ level do not allow to judge, whether the N- or O-atom in sulfinimine is stronger electron-donor to BF(3) . The problem seems to be solvable because chirality transfer phenomenon between chiral sulfinimine and achiral BF(3) is expected to be vibrational circular dichroism (VCD) active. Moreover, the bands associated with the achiral BF(3) molecule are predicted to be the most intense in the entire spectrum. However, the VCD band robustness analyses show that most of the chirality transfer modes of BF(3) are unreliable. Conversely, variation of VCD intensity with change of intermolecular distance, angle, and selected dihedrals between the complex partners shows that to establish the robustness of chirality transfer mode. It is also necessary to determine the influence of the potential energy surface (PES) shape on the VCD intensity. At the moment, there is still no universal criterion for the chirality transfer mode robustness and the conclusions formulated based on one system cannot be directly transferred even to a quite similar one. However, it is certain that more attention should be focused on relation of PES shape and the VCD mode robustness problem. Copyright © 2011 Wiley Periodicals, Inc.

  7. Rate dependence of electron transfer on donor-acceptor separation and on free enthalpy change. The Ru(bpy)32+/viologen2+ system

    International Nuclear Information System (INIS)

    Rau, H.; Frank, R.; Greiner, G.

    1986-01-01

    By attachment of hydrocarbon chains of different lengths to the bipyridyl ligands in Ru(bpy) 3 2+ we have adjusted the donor-acceptor separation in the electron-transfer system Ru[(C/sub n/H/sub 2n+1/) 2 bpyl 3 2+ /methylviolgen. Two electron-transfer reactions with different ΔG are investigated in fluid solution: the quenching of the excited complexes by methylviologen (MV 2+ ) which is exergonic with -0.4 eV and the thermal back electron transfer which is exergonic with -1.7 eV. We observe an exponential decrease of the quenching rate on distance. The back electron transfer is independent of donor-acceptor separation; electron transfer is found to take place at distances of 1.5 nm and more. The results are discussed in terms of a hypothesis on the interdependence of transfer distance and free enthalpy change and compared with current theories. In the framework of the simple classical Marcus model, the Marcus equation relating transfer rate and free enthalpy change is transposed into the Rehm-Weller equation by simple mathematical manipulations and the implications of this are discussed

  8. Magneto-ionic phase control in a quasi-layered donor/acceptor metal-organic framework by means of a Li-ion battery system

    Science.gov (United States)

    Taniguchi, Kouji; Narushima, Keisuke; Yamagishi, Kayo; Shito, Nanami; Kosaka, Wataru; Miyasaka, Hitoshi

    2017-06-01

    Electrical magnetism control is realized in a Li-ion battery system through a redox reaction involving ion migrations; “magneto-ionic control”. A quasi-layered metal-organic framework compound with a cross-linked π-conjugated/unconjugated one-dimensional chain motifs composed of electron-donor/acceptor units is developed as the cathode material. A change in magnetic phase from paramagnetic to ferrimagnetic is demonstrated by means of electron-filling control for the acceptor units via insertion of Li+-ions into pores in the material. The transition temperature is as high as that expected for highly π-conjugated layered systems, indicating an extension of π-conjugated exchange paths by rearranging coordination bonds in the first discharge process.

  9. The relationship between observer-based toxicity scoring and patient assessed symptom severity after treatment for head and neck cancer. A correlative cross sectional study of the DAHANCA toxicity scoring system and the EORTC quality of life questionnaires

    International Nuclear Information System (INIS)

    Jensen, Kenneth; Bonde Jensen, Anders; Grau, Cai

    2006-01-01

    Background and purpose: Morbidity is an important issue in cancer research. The observer-based toxicity scoring system used by DAHANCA (the Danish head and neck cancer study group) has proved itself sensitive to differences in toxicity in a large randomised study, but like other toxicity scoring systems it has not been formally validated. Conversely, the EORTC quality of life questionnaire (QLQ) has been validated as a tool for collecting information about the consequences of disease and treatment on the well being of cancer patients. The purpose of this study was to examine the relationship between the two methods of side effect recording. Patients and methods: One hundred and sixteen recurrence free patients with laryngeal (n=44), pharyngeal (n=34) and oral cavity (n=38) cancer attending follow-up after radiotherapy (n=83) or surgery (n=33) completed EORTC C30, the core questionnaire concerning general symptoms and function and EORTC H and N35 the head and neck specific questionnaire. The attending physicians in the follow-up clinic evaluated and recorded DAHANCA toxicity scores on the same patients. Results: The DAHANCA toxicity scoring system and the EORTC QLQ correlated with several clinical endpoints. The conceptually similar endpoints of the two methods correlated significantly. The objective endpoints of the DAHANCA scoring system were only correlated with quality of life endpoints to a very low degree. The DAHANCA toxicity scores had a low sensitivity (0.48-0.74) in detecting equivalent subjective complaints from the questionnaires and the observer-based scoring system severely underestimated patient complaints. A specific patient group where the DAHANCA score had a higher tendency to fail could not be detected. Conclusion: The DAHANCA toxicity score is an effective instrument in assessing objective treatment induced toxicity in head and neck cancer patients but insensitive and non-specific with regard to patient assessed subjective endpoints. This

  10. Evaluation of novel scoring system named 5-5-5 exacerbation grading scale for allergic conjunctivitis disease.

    Science.gov (United States)

    Shoji, Jun; Inada, Noriko; Sawa, Mitsuru

    2009-12-01

    The objective of this study is to evaluate the practical usefulness of a scoring system using the 5-5-5 exacerbation grading scale for allergic conjunctivitis disease (ACD). Subjects were 103 patients with ACD including 40 patients with vernal keratoconjunctivitis (VKC), 20 patients with atopic keratoconjunctivitis (AKC), and 43 patients with allergic conjunctivitis (AC). The 5-5-5 exacerbation grading scale consists of the following 3 graded groups of clinical observations: the 100-point-grade group (100 points for each observation) includes active giant papillae, gelatinous infiltrates of the limbus, exfoliative epithelial keratopathy, shield ulcer and papillary proliferation at lower palpebral conjunctiva; the 10-point-grade group (10 points for each observation) includes blepharitis, papillary proliferation with velvety appearance, Horner-Trantas spots, edema of bulbal conjunctiva, and superficial punctate keratopathy; and the 1-point-grade group (1 point for each observation) includes papillae at upper palpebral conjunctiva, follicular lesion at lower palpebral conjunctiva, hyperemia of palpebral conjunctiva, hyperemia of bulbal conjunctiva, and lacrimal effusion. The total points in each grade group were determined as the severity score of the 5-5-5 exacerbation grading scale. The median severity scores of the 5-5-5 exacerbation grading scale in VKC, AKC and AC were 243 (range: 12-444), 32.5 (11-344), and 13 (2-33), respectively. The severity score of each ACD disease type was significantly different (P Kruskal-Wallis test). The severity of each type of ACD was classified as severe, moderate, or mild according to the severity score. The 5-5-5 exacerbation grading scale is a useful clinical tool for grading the severity of each type of ACD.

  11. Predictors of Donor Heart Utilization for Transplantation in United States.

    Science.gov (United States)

    Trivedi, Jaimin R; Cheng, Allen; Gallo, Michele; Schumer, Erin M; Massey, H Todd; Slaughter, Mark S

    2017-06-01

    Optimum use of donor organs can increase the reach of the transplantation therapy to more patients on waiting list. The heart transplantation (HTx) has remained stagnant in United States over the past decade at approximately 2,500 HTx annually. With the use of the United Network of Organ Sharing (UNOS) deceased donor database (DCD) we aimed to evaluate donor factors predicting donor heart utilization. UNOS DCD was queried from 2005 to 2014 to identify total number of donors who had at least one of their organs donated. We then generated a multivariate logistic regression model using various demographic and clinical donor factors to predict donor heart use for HTx. Donor hearts not recovered due to consent or family issues or recovered for nontransplantation reasons were excluded from the analysis. During the study period there were 80,782 donors of which 23,606 (29%) were used for HTx, and 38,877 transplants (48%) were not used after obtaining consent because of poor organ function (37%), donor medical history (13%), and organ refused by all programs (5%). Of all, 22,791 donors with complete data were used for logistic regression (13,389 HTx, 9,402 no-HTx) which showed significant predictors of donor heart use for HTx. From this model we assigned probability of donor heart use and identified 3,070 donors with HTx-eligible unused hearts for reasons of poor organ function (28%), organ refused by all programs (15%), and recipient not located (9%). An objective system based on donor factors can predict donor heart use for HTx and may help increase availability of hearts for transplantation from existing donor pool. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. 77 FR 47707 - Public Housing Assessment System (PHAS): Physical Condition Scoring Notice and Revised Dictionary...

    Science.gov (United States)

    2012-08-09

    .../Cooling System Leaks (HVAC--Building Systems) deficiency, coolant, water or steam escaping from the unit... surface failure, or evidence of water infiltration or other moisture producing conditions,'' and the title... beyond the control of a PHA. For instance, pooling of water on a site may not be fixable during winter...

  13. Marginal kidney donor

    Directory of Open Access Journals (Sweden)

    Ganesh Gopalakrishnan

    2007-01-01

    Full Text Available Renal transplantation is the treatment of choice for a medically eligible patient with end stage renal disease. The number of renal transplants has increased rapidly over the last two decades. However, the demand for organs has increased even more. This disparity between the availability of organs and waitlisted patients for transplants has forced many transplant centers across the world to use marginal kidneys and donors. We performed a Medline search to establish the current status of marginal kidney donors in the world. Transplant programs using marginal deceased renal grafts is well established. The focus is now on efforts to improve their results. Utilization of non-heart-beating donors is still in a plateau phase and comprises a minor percentage of deceased donations. The main concern is primary non-function of the renal graft apart from legal and ethical issues. Transplants with living donors outnumbered cadaveric transplants at many centers in the last decade. There has been an increased use of marginal living kidney donors with some acceptable medical risks. Our primary concern is the safety of the living donor. There is not enough scientific data available to quantify the risks involved for such donation. The definition of marginal living donor is still not clear and there are no uniform recommendations. The decision must be tailored to each donor who in turn should be actively involved at all levels of the decision-making process. In the current circumstances, our responsibility is very crucial in making decisions for either accepting or rejecting a marginal living donor.

  14. Improvement of the Mair scoring system using structural equations modeling for classifying the diagnostic adequacy of cytology material from thyroid lesions.

    Science.gov (United States)

    Kulkarni, H R; Kamal, M M; Arjune, D G

    1999-12-01

    The scoring system developed by Mair et al. (Acta Cytol 1989;33:809-813) is frequently used to grade the quality of cytology smears. Using a one-factor analytic structural equations model, we demonstrate that the errors in measurement of the parameters used in the Mair scoring system are highly and significantly correlated. We recommend the use of either a multiplicative scoring system, using linear scores, or an additive scoring system, using exponential scores, to correct for the correlated errors. We suggest that the 0, 1, and 2 points used in the Mair scoring system be replaced by 1, 2, and 4, respectively. Using data on fine-needle biopsies of 200 thyroid lesions by both fine-needle aspiration (FNA) and fine-needle capillary sampling (FNC), we demonstrate that our modification of the Mair scoring system is more sensitive and more consistent with the structural equations model. Therefore, we recommend that the modified Mair scoring system be used for classifying the diagnostic adequacy of cytology smears. Diagn. Cytopathol. 1999;21:387-393. Copyright 1999 Wiley-Liss, Inc.

  15. Evaluation of the Physiological and Operative Severity Score for the Enumeration of Mortality and Morbidity (POSSUM) scoring system in elderly patients with pressure sores undergoing fasciocutaneous flap-reconstruction.

    Science.gov (United States)

    Mizumoto, Kazuo; Morita, Eishin

    2009-01-01

    The aim of the present study was to predict operative morbidity in elderly patients with deep pressure sores by using the Physiological and Operative Severity Score for the Enumeration of Mortality and Morbidity (POSSUM) scoring system. Fifteen patients over 70 years old were retrospectively reviewed who had undergone gluteus maximus fasciocutaneous flap-reconstruction for pressure sores of the sacral region from 1 April 2005 to 31 March 2007. Complications were seen in six cases (40%) after operation. Four were wound infection, one was chest infection and another was septicemia. The subjects were divided into two groups by the presence (complicated group) or absence (non-complicated group) of postoperative complications. Each item of physiological scores, physiological score (PS), operative severity score (OS) and predicted morbidity rate (R) were calculated and compared between two groups. As a result, hemoglobin (P = 0.0276), PS (P = 0.0023) and R (P = 0.0078) differed significantly between the two groups. It is noteworthy that the PS were over 25 in all of the complicated group, but in only one of nine in the non-complicated group (P = 0.0014). Our study suggests that, for pressure sores in the sacral region in elderly patients, gluteus maximus fasciocutaneous flap-reconstruction can be employed in patients whose PS are under 24 in the POSSUM scoring system.

  16. The Zhongshan Score

    Science.gov (United States)

    Zhou, Lin; Guo, Jianming; Wang, Hang; Wang, Guomin

    2015-01-01

    Abstract In the zero ischemia era of nephron-sparing surgery (NSS), a new anatomic classification system (ACS) is needed to adjust to these new surgical techniques. We devised a novel and simple ACS, and compared it with the RENAL and PADUA scores to predict the risk of NSS outcomes. We retrospectively evaluated 789 patients who underwent NSS with available imaging between January 2007 and July 2014. Demographic and clinical data were assessed. The Zhongshan (ZS) score consisted of three parameters. RENAL, PADUA, and ZS scores are divided into three groups, that is, high, moderate, and low scores. For operative time (OT), significant differences were seen between any two groups of ZS score and PADUA score (all P RENAL showed no significant difference between moderate and high complexity in OT, WIT, estimated blood loss, and increase in SCr. Compared with patients with a low score of ZS, those with a high or moderate score had 8.1-fold or 3.3-fold higher risk of surgical complications, respectively (all P RENAL score, patients with a high or moderate score had 5.7-fold or 1.9-fold higher risk of surgical complications, respectively (all P RENAL and PADUA scores. ZS score could be used to reflect the surgical complexity and predict the risk of surgical complications in patients undergoing NSS. PMID:25654399

  17. Applying the System Component and Operationally Relevant Evaluation (SCORE) Framework to Evaluate Advanced Military Technologies

    Science.gov (United States)

    2010-03-01

    and charac- terize the actions taken by the soldier (e.g., running, walking, climbing stairs ). Real-time image capture and exchange N The ability of...multimedia information sharing among soldiers in the field, two-way speech translation systems, and autonomous robotic platforms. Key words: Emerging...soldiers in the field, two-way speech translation systems, and autonomous robotic platforms. It has been the foundation for 10 technology evaluations

  18. Application of modified R.E.N.A.L. nephrometry score system in evaluating the retroperitoneal partial nephrectomy for T1 renal cell carcinoma.

    Science.gov (United States)

    Wang, Qinzhang; Qian, Biao; Li, Qiang; Ni, Zhao; Li, Yinglong; Wang, Xinmin

    2015-01-01

    This study aims to investigate the application of the modified R.E.N.A.L. nephrometry score system in evaluating the operation difficulty of retroperitoneal partial nephrectomy in T1 renal cell carcinoma patients. A total of 52 patients with T1 renal cell carcinoma were enrolled. They all had retroperitoneal partial nephrectomy. Their clinical data was retrospectively analyzed. R.E.N.A.L. nephrometry score system was modified based on the features of retroperitoneal partial nephrectomy. The specificity, sensitivity and Youden index were compared between R.E.N.A.L. nephrometry score system and the modified R.E.N.A.L. nephrometry score system. The effect of the modified R.E.N.A.L. nephrometry score system on perioperative outcomes was analyzed. Three degrees of operation difficulty were defined by the modified R.E.N.A.L. nephrometry score system, which included the low, medium and high degree of operation difficulty. The specificity, sensitivity and Youden index of the modified R.E.N.A.L. nephrometry score system were better than those of the original R.E.N.A.L. nephrometry score system. Compared with low degree of operation difficulty, patients with medium and high degree of operation difficulty had significantly higher levels of operative time, warm ischemia time, and intraoperative blood loss (P system has a good effect in evaluating the operation difficulty of retroperitoneal partial nephrectomy.

  19. Comparison of three scoring systems in predicting clinical outcomes in patients with acute upper gastrointestinal bleeding: a prospective observational study.

    Science.gov (United States)

    Zhong, Min; Chen, Wan Jun; Lu, Xiao Ye; Qian, Jie; Zhu, Chang Qing

    2016-12-01

    To compare the performances of the Glasgow-Blatchford score (GBS), modified GBS (mGBS) and AIMS65 in predicting clinical outcomes in patients with acute upper gastrointestinal bleeding (AUGIB). This study enrolled 320 consecutive patients with AUGIB. Patients at high and low risks of developing adverse clinical outcomes (rebleeding, the need of clinical intervention and death) were categorized according to the GBS, mGBS and AIMS65 scoring systems. The outcome of the patients were the occurrences of adverse clinical outcomes. The areas under the receiver operating characteristics curve (AUROC) of three scoring systems were compared. Irrespective of the systems used, the high-risk groups showed higher rates of rebleeding, intervention and death compared with the low-risk groups (P < 0.05). For the prediction of rebleeding, AIMS65 (AUROC 0.735, 95% CI 0.667-0.802) performed significantly better than GBS (AUROC 0.672, 95% CI 0.597-0.747; P < 0.01) and mGBS (AUROC 0.677, 95% CI 0.602-0.753; P < 0.01). For the prediction of interventions, there was no significant difference among the three systems (GBS: AUROC 0.769, 95% CI 0.668-0.870; mGBS: AUROC 0.745, 95% CI 0.643-0.847; AIMS65: AUROC 0.746, 95% CI 0.640-0.851). For the prediction of in-hospital mortality, there was no significant difference among the three systems (GBS: AUROC 0.796, 95% CI 0.694-0.898; mGBS: AUROC 0.803, 95% CI 0.703-0.904; AIMS65: AUROC 0.786, 95% CI 0.670-0.903). The three scoring systems are reliable and accurate in predicting the rates of rebleeding, surgery and mortality in AUGIB. However, AIMS65 outperforms GBS and mGBS in predicting rebleeding. © 2016 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  20. National Marrow Donor Program

    National Research Council Canada - National Science Library

    Setterholm, Michelle

    2008-01-01

    ... a nationwide contingency response plan. 2. Rapid Identification of Matched Donors : Increase operational efficiencies that accelerate the search process and increase patient access are key to preparedness in a contingency event. pa 3...

  1. Non-alcoholic fatty liver disease - histological scoring systems: a large cohort single-center, evaluation study.

    Science.gov (United States)

    Rastogi, Archana; Shasthry, Saggere Muralikrishna; Agarwal, Ayushi; Bihari, Chhagan; Jain, Priyanka; Jindal, Ankur; Sarin, Shiv

    2017-11-01

    Non-alcoholic fatty liver disease (NAFLD) is an increasingly common cause of chronic liver disease. Till date, liver biopsy remains the gold standard for identification and quantification of the wide histological spectra of NAFLD. Histological scorings are very useful and widely applied for the diagnosis and management in clinical trials and follow-up studies of non-alcoholic steatohepatitis (NASH). However, in view of scarce published literature, there is a need to evaluate them in large cohort of NAFLD. This study was aimed to evaluate the two histological scoring systems (NAS-CRN, SAF) in the diagnosis of NAFLD and to assess the role of histological characteristics as injury markers in NAFLD. Retrospective histological study of liver biopsies of 1000 patients diagnosed as NAFLD, between 2010 and 2016, was conducted. Histopathologic evaluation and semiquantiative scoring based on NAS-CRN and SAF algorithm and their correlation with serum aminotransferase and fibrosis were performed. Liver biopsies were classified according to the NAS-CRN scoring, as NAS <3 (not NASH) in 72 (7.2%), NAS 3-4 (borderline NASH) in 310 (31%), and NAS ≥5 (definite NASH) in 618 (61.8%), and SAF classified 117 (11.7%) not NASH and 883 (88.3%) definite NASH. There was excellent concordance for definite NASH and not NASH; however, 88.06% of borderline NASH was classified as NASH by SAF. 76.39% by NAS and 78.63% by SAF algorithm who were diagnosed as not NASH showed the presence of fibrosis; however, higher stages of fibrosis were significantly more prevalent in definite NASH, excluding burnt-out cirrhosis. Serum ALT was significantly associated with increasing stages of fibrosis (p < 0.001) and the three categories (not NASH, borderline NASH, and definite NASH) when classified as with/without fibrosis (p < 0.001). Steatosis of higher grades, more ballooned cells, and more foci of Lobular Inflammation were found in significantly higher proportion of patients with NASH (p < 0

  2. Validity and sensitivity to change of the semi-quantitative OMERACT ultrasound scoring system for tenosynovitis in patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Ammitzbøll-Danielsen, Mads; Østergaard, Mikkel; Naredo, Esperanza

    2016-01-01

    OBJECTIVES: The aim was to evaluate the metric properties of the semi-quantitative OMERACT US scoring system vs a novel quantitative US scoring system for tenosynovitis, by testing its intra- and inter-reader reliability, sensitivity to change and comparison with clinical tenosynovitis scoring...... in a 6-month follow-up study. METHODS: US and clinical assessments of the tendon sheaths of the clinically most affected hand and foot were performed at baseline, 3 and 6 months in 51 patients with RA. Tenosynovitis was assessed using the semi-quantitative scoring system (0-3) proposed by the OMERACT US...... tenosynovitis score was performed, calculating a sum score per patient. RESULTS: The intra- and inter-observer agreements for US tenosynovitis assessments were very good at baseline and for change for GS and CD, but less good for PI. The smallest detectable change was 0.97 for GS, 0.93 for CD and 30.1 for PI...

  3. A cross-sectional study of the Birmingham Vasculitis Activity Score version 3 in systemic vasculitis.

    LENUS (Irish Health Repository)

    Suppiah, Ravi

    2011-05-01

    Assessment of disease activity in vasculitis can be achieved using the BVAS, a clinical checklist of relevant symptoms, signs and features of active disease. The aim of this study was to revalidate the BVAS version 3 (BVAS v. 3) in a cohort of patients with systemic vasculitis.

  4. The Effect of Individualized Instruction System on the Academic Achievement Scores of Students

    Directory of Open Access Journals (Sweden)

    Ferhat Bahçeci

    2016-01-01

    Full Text Available A web-based learning portal offering individualized learning was developed by utilizing rule-based knowledge representation and artificial intelligence techniques of expert systems in order to reduce the uncertainties of learning to minimum and to construct an intelligent tutoring system. This portal offers individualized learning content based on the individual’s level of cognitive knowledge. In order to determine the effects of the developed system on the student achievement, the system was tested in an 8-week-long study on the students of Software Engineering Department of Technology Faculty. The pretest-posttest control group experimental design was used in the study. The experimental group received education with Individualized Instruction Portal while the control group received education in traditional learning environment. Academic achievement test was used as the data collection tool. In order to test the research hypotheses, data obtained from the data collection tools were analysed in terms of frequency, percentages, and dependent-independent t-test with statistical software program. Based on the results, no significant differences were found between the groups in terms of the pretest. On the other hand, significant differences were found between experimental and control group in terms of the posttest. It was concluded that individualized learning portal had positive effect on the students’ learning when used in combination with traditional learning environment.

  5. The predictive validity of grade point average scores in a partial lottery medical school admission system

    NARCIS (Netherlands)

    Cohen-Schotanus, Janke; Muijtjens, Arno M. M.; Reinders, Jan J.; Agsteribbe, Jessica; van Rossum, Herman J. M.; van der Vleuten, Cees P. M.

    2006-01-01

    PURPOSE To ascertain whether the grade point average (GPA) of school-leaving examinations is related to study success, career development and scientific performance. The problem of restriction of range was expected to be partially reduced due to the use of a national lottery system weighted in

  6. Examining the association of injury with the Functional Movement Screen and Landing Error Scoring System in military recruits undergoing 16 weeks of introductory fitness training.

    Science.gov (United States)

    Everard, Eoin; Lyons, Mark; Harrison, Andrew J

    2018-06-01

    To examine the association of injury with the Functional Movement Screen (FMS) and Landing Error Scoring System (LESS) in military recruits undergoing an intensive 16-week training block. Prospective cohort study. One hundred and thirty-two entry-level male soldiers (18-25years) were tested using the FMS and LESS. The participants underwent an intensive 16-week training program with injury data recorded daily. Chi-squared statistics were used to examine associations between injury risk and (1) poor LESS scores, (2) any score of 1 on the FMS and (3) composite FMS score of ≤14. A composite FMS score of ≤14 was not a significant predictor of injury. LESS scores of >5 and having a score of 1 on any FMS test were significantly associated with injury. LESS scores had greater relative risk, sensitivity and specificity (2.2 (95% CI=1.48-3.34); 71% and 87% respectively) than scores of 1 on the FMS (relative risk=1.32 (95% CI=1.0-1.7); sensitivity=50% and specificity=76%). There was no association between composite FMS score and injury but LESS scores and scores of 1 in the FMS test were significantly associated with injury in varying degrees. LESS scores had a much better association with injury than both any scores of 1 on the FMS and a combination of LESS scores and scores of 1 on the FMS. Furthermore, the LESS provides comparable information related to injury risk as other well-established markers associated with injury such as age, muscular strength and previous injury. Copyright © 2017. Published by Elsevier Ltd.

  7. A scoring system based on artificial neural network for predicting 10-year survival in stage II A colon cancer patients after radical surgery

    Science.gov (United States)

    Jiang, Wu; Lu, Shi-Xun; Lu, Zhen-Hai; Li, Pei-Xing; Yun, Jing-Ping; Zhang, Rong-Xin; Pan, Zhi-Zhong; Wan, De-Sen

    2016-01-01

    Nearly 20% patients with stage II A colon cancer will develop recurrent disease post-operatively. The present study aims to develop a scoring system based on Artificial Neural Network (ANN) model for predicting 10-year survival outcome. The clinical and molecular data of 117 stage II A colon cancer patients from Sun Yat-sen University Cancer Center were used for training set and test set; poor pathological grading (score 49), reduced expression of TGFBR2 (score 33), over-expression of TGF-β (score 45), MAPK (score 32), pin1 (score 100), β-catenin in tumor tissue (score 50) and reduced expression of TGF-β in normal mucosa (score 22) were selected as the prognostic risk predictors. According to the developed scoring system, the patients were divided into 3 subgroups, which were supposed with higher, moderate and lower risk levels. As a result, for the 3 subgroups, the 10-year overall survival (OS) rates were 16.7%, 62.9% and 100% (P < 0.001); and the 10-year disease free survival (DFS) rates were 16.7%, 61.8% and 98.8% (P < 0.001) respectively. It showed that this scoring system for stage II A colon cancer could help to predict long-term survival and screen out high-risk individuals for more vigorous treatment. PMID:27008710

  8. Diagnostic accuracy of the Barr and Blethyn radiological scoring systems for childhood constipation assessed using colonic transit time as the gold standard

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, Claire R.; Wylie, Anna B.Z.; Adams, Charlotte [Royal Victoria Infirmary, Department of Paediatric Surgery, Newcastle upon Tyne (United Kingdom); Lee, Richard E. [Royal Victoria Infirmary, Department of Radiology, Newcastle upon Tyne (United Kingdom); Jaffray, Bruce [University of Newcastle upon Tyne, School of Clinical Medical Sciences (Child Health), Sir James Spence Institute, Newcastle upon Tyne (United Kingdom)

    2009-07-15

    Constipation is a common childhood symptom and abdominal radiography is advocated in diagnosis and management. To assess the reproducibility and diagnostic accuracy of the Barr and Blethyn systems for quantifying constipation on abdominal radiographs in children. Radiographs were scored by three observers of increasing radiological experience (student, junior doctor, consultant). Abdominal radiographs produced during measurement of colonic transit time (CTT) were classified as constipated or normal based on the value of the transit time, and were scored using both systems by observers blinded to the CTT. Abdominal radiographs obtained in children for reasons other than constipation were classed as normal and similarly scored. Reproducibility was measured using the kappa statistic. Diagnostic accuracy was measured using the area under the curve (AUC) for the receiver operator characteristic (ROC) curve. Using either system, scores were higher for constipated children (P<0.01). The consultant produced higher scores than the other observers (P<0.01). Interobserver reproducibility was moderate with the best kappa value only 0.48. The best correlation between score and CTT was 0.51 (junior doctor scores). Diagnostic accuracy of the scores was only moderate, with the largest AUC for a ROC curve of 0.84 for the consultant using the Barr score. Scoring of abdominal radiographs in the assessment of childhood constipation should be abandoned because it is dependent on the experience of the observer, is poorly reproducible, and does not accurately discriminate between constipated children and children without constipation. (orig.)

  9. Diagnostic accuracy of the Barr and Blethyn radiological scoring systems for childhood constipation assessed using colonic transit time as the gold standard

    International Nuclear Information System (INIS)

    Jackson, Claire R.; Wylie, Anna B.Z.; Adams, Charlotte; Lee, Richard E.; Jaffray, Bruce

    2009-01-01

    Constipation is a common childhood symptom and abdominal radiography is advocated in diagnosis and management. To assess the reproducibility and diagnostic accuracy of the Barr and Blethyn systems for quantifying constipation on abdominal radiographs in children. Radiographs were scored by three observers of increasing radiological experience (student, junior doctor, consultant). Abdominal radiographs produced during measurement of colonic transit time (CTT) were classified as constipated or normal based on the value of the transit time, and were scored using both systems by observers blinded to the CTT. Abdominal radiographs obtained in children for reasons other than constipation were classed as normal and similarly scored. Reproducibility was measured using the kappa statistic. Diagnostic accuracy was measured using the area under the curve (AUC) for the receiver operator characteristic (ROC) curve. Using either system, scores were higher for constipated children (P<0.01). The consultant produced higher scores than the other observers (P<0.01). Interobserver reproducibility was moderate with the best kappa value only 0.48. The best correlation between score and CTT was 0.51 (junior doctor scores). Diagnostic accuracy of the scores was only moderate, with the largest AUC for a ROC curve of 0.84 for the consultant using the Barr score. Scoring of abdominal radiographs in the assessment of childhood constipation should be abandoned because it is dependent on the experience of the observer, is poorly reproducible, and does not accurately discriminate between constipated children and children without constipation. (orig.)

  10. A scoring system based on artificial neural network for predicting 10-year survival in stage II A colon cancer patients after radical surgery.

    Science.gov (United States)

    Peng, Jian-Hong; Fang, Yu-Jing; Li, Cai-Xia; Ou, Qing-Jian; Jiang, Wu; Lu, Shi-Xun; Lu, Zhen-Hai; Li, Pei-Xing; Yun, Jing-Ping; Zhang, Rong-Xin; Pan, Zhi-Zhong; Wan, De Sen

    2016-04-19

    Nearly 20% patients with stage II A colon cancer will develop recurrent disease post-operatively. The present study aims to develop a scoring system based on Artificial Neural Network (ANN) model for predicting 10-year survival outcome. The clinical and molecular data of 117 stage II A colon cancer patients from Sun Yat-sen University Cancer Center were used for training set and test set; poor pathological grading (score 49), reduced expression of TGFBR2 (score 33), over-expression of TGF-β (score 45), MAPK (score 32), pin1 (score 100), β-catenin in tumor tissue (score 50) and reduced expression of TGF-β in normal mucosa (score 22) were selected as the prognostic risk predictors. According to the developed scoring system, the patients were divided into 3 subgroups, which were supposed with higher, moderate and lower risk levels. As a result, for the 3 subgroups, the 10-year overall survival (OS) rates were 16.7%, 62.9% and 100% (P < 0.001); and the 10-year disease free survival (DFS) rates were 16.7%, 61.8% and 98.8% (P < 0.001) respectively. It showed that this scoring system for stage II A colon cancer could help to predict long-term survival and screen out high-risk individuals for more vigorous treatment.

  11. THE USE OF ELECTRONIC JOURNALS IN SCORE RATING ACCOUNTING SYSTEM OF EDUCATIONAL ACHIEVEMENTS OF STUDENTS

    Directory of Open Access Journals (Sweden)

    И Н Куринин

    2016-12-01

    Full Text Available The article describes a method of using electronic journals as a tool for efficient organization of teacher’s practical work in conditions of computerization of educational process and the widespread implementation of credit-modular system of educational process organization and grade-rating system for basic educational programs proficiency examination. A version of the electronic journal designed by the authors and realized in the program MS Excel is also presented in the article. An example of a completed “Academic Progress” page of the university educational web portal is discussed. It contains a marked electronic student grade book section and the stated conditions and criteria for grades allocation, according to a 100-point scale.

  12. Comparison of discrimination and prognostic value of two US Doppler scoring systems in rheumatoid arthritis patients

    DEFF Research Database (Denmark)

    Ellegaard, Karen; Terslev, Lene; Christensen, Robin

    2014-01-01

    images. The SRM, predictive validity and discriminative ability for both systems were calculated using DAS28 as the measure of disease improvement. RESULTS: Fourty-six patients with RA (80% females) were included. The mean Doppler activity at baseline was QS:24.4% (SD=17.7%) and SQS:2.0 (SD=0.......6). A decrease in Doppler activity was seen for both systems after anti-TNF-α therapy. Sensitivity to change was seen, SRM=-0.52 (95%CI; -0.83 to -0.21; QS) and -0.24 (-0.53 to -0.05; SQS). Predictive value was poor (QS rs=-0.24; SQS rs=-0.05). Construct validity was; QS: rs=0.29, SQS: rs=0.23. CONCLUSIONS: Both...

  13. LAIX-score : a design framework for live audience interaction management systems

    OpenAIRE

    Kuikkaniemi, Kai

    2017-01-01

    This study focuses on computer-supported live audience interaction. In conventional lectures audience interacts explicitly with the performer for example by waving hand and asking question directly or clapping hands. For decades, non digital audience response systems have enabled simple multiple option audience interaction patterns. Modern mobile personal computing devices, digital projectors, wireless networks and real time software platforms enable creation of new kinds of interaction patte...

  14. The relationship between observer-based toxicity scoring and patient assessed symptom severity after treatment for head and neck cancer. A correlative cross sectional study of the DAHANCA toxicity scoring system and the EORTC quality of life questionnaires

    DEFF Research Database (Denmark)

    Jensen, Kenneth; Bonde Jensen, Anders; Grau, Cai

    2006-01-01

          toxicity scoring systems it has not been formally validated. Conversely,       the EORTC quality of life questionnaire (QLQ) has been validated as a tool       for collecting information about the consequences of disease and treatment       on the well being of cancer patients. The purpose of this study......) completed       EORTC C30, the core questionnaire concerning general symptoms and function       and EORTC H&N35 the head and neck specific questionnaire. The attending       physicians in the follow-up clinic evaluated and recorded DAHANCA toxicity       scores on the same patients. RESULTS: The DAHANCA...... low degree. The       DAHANCA toxicity scores had a low sensitivity (0.48-0.74) in detecting       equivalent subjective complaints from the questionnaires and the       observer-based scoring system severely underestimated patient complaints.       A specific patient group where the DAHANCA score had...

  15. Classifying and Standardizing Panfacial Trauma With a New Bony Facial Trauma Score.

    Science.gov (United States)

    Casale, Garrett G A; Fishero, Brian A; Park, Stephen S; Sochor, Mark; Heltzel, Sara B; Christophel, J Jared

    2017-01-01

    The practice of facial trauma surgery would benefit from a useful quantitative scale that measures the extent of injury. To develop a facial trauma scale that incorporates only reducible fractures and is able to be reliably communicated to health care professionals. A cadaveric tissue study was conducted from October 1 to 3, 2014. Ten cadaveric heads were subjected to various degrees of facial trauma by dropping a fixed mass onto each head. The heads were then imaged with fine-cut computed tomography. A Bony Facial Trauma Scale (BFTS) for grading facial trauma was developed based only on clinically relevant (reducible) fractures. The traumatized cadaveric heads were then scored using this scale as well as 3 existing scoring systems. Regression analysis was used to determine correlation between degree of incursion of the fixed mass on the cadaveric heads and trauma severity as rated by the scoring systems. Statistical analysis was performed to determine correlation of the scores obtained using the BFTS with those of the 3 existing scoring systems. Scores obtained using the BFTS were not correlated with dentition (95% CI, -0.087 to 1.053; P = .08; measured as absolute number of teeth) or age of the cadaveric donor (95% CI, -0.068 to 0.944; P = .08). Facial trauma scores. Among all 10 cadaveric specimens (9 male donors and 1 female donor; age range, 41-87 years; mean age, 57.2 years), the facial trauma scores obtained using the BFTS correlated with depth of penetration of the mass into the face (odds ratio, 4.071; 95% CI, 1.676-6.448) P = .007) when controlling for presence of dentition and age. The BFTS scores also correlated with scores obtained using 3 existing facial trauma models (Facial Fracture Severity Scale, rs = 0.920; Craniofacial Disruption Score, rs = 0.945; and ZS Score, rs = 0.902; P trauma scales. Scores obtained using the BFTS were not correlated with dentition (odds ratio, .482; 95% CI, -0.087 to 1.053; P = .08; measured

  16. A new extranodal scoring system based on the prognostically relevant extranodal sites in diffuse large B-cell lymphoma, not otherwise specified treated with chemoimmunotherapy.

    Science.gov (United States)

    Hwang, Hee Sang; Yoon, Dok Hyun; Suh, Cheolwon; Huh, Jooryung

    2016-08-01

    Extranodal involvement is a well-known prognostic factor in patients with diffuse large B-cell lymphomas (DLBCL). Nevertheless, the prognostic impact of the extranodal scoring system included in the conventional international prognostic index (IPI) has been questioned in an era where rituximab treatment has become widespread. We investigated the prognostic impacts of individual sites of extranodal involvement in 761 patients with DLBCL who received rituximab-based chemoimmunotherapy. Subsequently, we established a new extranodal scoring system based on extranodal sites, showing significant prognostic correlation, and compared this system with conventional scoring systems, such as the IPI and the National Comprehensive Cancer Network-IPI (NCCN-IPI). An internal validation procedure, using bootstrapped samples, was also performed for both univariate and multivariate models. Using multivariate analysis with a backward variable selection, we found nine extranodal sites (the liver, lung, spleen, central nervous system, bone marrow, kidney, skin, adrenal glands, and peritoneum) that remained significant for use in the final model. Our newly established extranodal scoring system, based on these sites, was better correlated with patient survival than standard scoring systems, such as the IPI and the NCCN-IPI. Internal validation by bootstrapping demonstrated an improvement in model performance of our modified extranodal scoring system. Our new extranodal scoring system, based on the prognostically relevant sites, may improve the performance of conventional prognostic models of DLBCL in the rituximab era and warrants further external validation using large study populations.

  17. Live donor transplantation--the incompetent donor: comparative law.

    Science.gov (United States)

    Wolfman, Samuel; Shaked, Tali

    2008-12-01

    Informed consent of the patient to medical treatment is an essential prerequisite for any invasive medical procedure. However in emergency cases, when the patient is unable to sign a consent form due to unconsciousness or to psychotic state, than the primary medical consideration shall take place. In such a case, in order to save life or even prevent a major medical hazard to the patient, doctors are allowed, in certain cases and in accordance with well accepted medical practice, to perform invasive procedures, major surgery or risky pharmacological treatment, without the explicit consent of the patient. All the above refers to the cases when avoidance of such non-consented treatment may harm severely the health and wellbeing of the patient and there is no doubt that such treatment is for the ultimate benefit of the patient. The question, however, shall arise when such a medical procedure is not necessarily for the benefit of the patient, but rather for the benefit of somebody else. Such is the case in the transplantation area and the question of living donor-donee relationship. This paper shall analyze the legal situation in cases of non competent donors whose consent cannot be considered legal consent given in full understanding and out of free will. It will also compare three legal systems, the Israeli, the American and the traditional Jewish law, with regard to the different approaches to this human problem, where the autonomy of the donor may be sacrificed for the purpose of saving life of another person.

  18. Comparison of the severity of lower extremity arterial disease in smokers and patients with diabetes using a novel duplex Doppler scoring system

    Energy Technology Data Exchange (ETDEWEB)

    Hiremath, Rudresh; Gowda, Goutham; Ibrahim, Jebin; Reddy, Harish T.; Chodiboina, Haritha; Shah, Rushit [Radiodiagnosis and Imaging, KVG Medical College and Hospital, Sullia (India)

    2017-07-15

    The aim of this study was to validate the diagnostic feasibility of a novel scoring system of peripheral arterial disease (PAD) in smokers and patients with diabetes depending on duplex Doppler sonographic features. Patients presenting with the symptomatology of PAD were divided into three groups: diabetes only, smoking only, and smokers with diabetes. The patients were clinically examined, a clinical severity score was obtained, and the subjects were categorized into the three extrapolated categories of mild, moderate, and severe. All 106 subjects also underwent a thorough duplex Doppler examination, and various aspects of PAD were assessed and tabulated. These components were used to create a novel duplex Doppler scoring system. Depending on the scores obtained, each individual was categorized as having mild, moderate, or severe illness. The Cohen kappa value was used to assess interobserver agreement between the two scoring systems. Interobserver agreement between the traditional Rutherford clinical scoring system and the newly invented duplex Doppler scoring system showed a kappa value of 0.83, indicating significant agreement between the two scoring systems (P<0.001). Duplex Doppler imaging is an effective screening investigation for lower extremity arterial disease, as it not only helps in its diagnosis, but also in the staging and grading of the disease, providing information that can be utilized for future management and treatment planning.

  19. Comparison of the severity of lower extremity arterial disease in smokers and patients with diabetes using a novel duplex Doppler scoring system.

    Science.gov (United States)

    Hiremath, Rudresh; Gowda, Goutham; Ibrahim, Jebin; Reddy, Harish T; Chodiboina, Haritha; Shah, Rushit

    2017-07-01

    The aim of this study was to validate the diagnostic feasibility of a novel scoring system of peripheral arterial disease (PAD) in smokers and patients with diabetes depending on duplex Doppler sonographic features. Patients presenting with the symptomatology of PAD were divided into three groups: diabetes only, smoking only, and smokers with diabetes. The patients were clinically examined, a clinical severity score was obtained, and the subjects were categorized into the three extrapolated categories of mild, moderate, and severe. All 106 subjects also underwent a thorough duplex Doppler examination, and various aspects of PAD were assessed and tabulated. These components were used to create a novel duplex Doppler scoring system. Depending on the scores obtained, each individual was categorized as having mild, moderate, or severe illness. The Cohen kappa value was used to assess interobserver agreement between the two scoring systems. Interobserver agreement between the traditional Rutherford clinical scoring system and the newly invented duplex Doppler scoring system showed a kappa value of 0.83, indicating significant agreement between the two scoring systems (PDuplex Doppler imaging is an effective screening investigation for lower extremity arterial disease, as it not only helps in its diagnosis, but also in the staging and grading of the disease, providing information that can be utilized for future management and treatment planning.

  20. Development of a profile scoring system for assessing the psychosocial situation of patients with chronic musculoskeletal pain

    Directory of Open Access Journals (Sweden)

    Nikaido T

    2017-08-01

    Full Text Available Takuya Nikaido,1 Shingo Fukuma,2,3 Takafumi Wakita,4 Miho Sekiguchi,1 Shoji Yabuki,1 Yoshihiro Onishi,5 Shunichi Fukuhara,2,3 Shin-ichi Konno1 On behalf of the profile scoring system for multilateral assessment of social factors in patients with chronic musculoskeletal pain study group 1Department of Orthopaedic Surgery, Fukushima Medical University School of Medicine, Fukushima, 2Department of Healthcare Epidemiology, Kyoto University, Graduate School of Medicine and Public Health, Kyoto, 3Center for Innovative Research for Communities and Clinical Excellence (CIRC2LE, Fukushima Medical University, Fukushima, 4Department of Sociology, Kansai University, Osaka, 5Institute for Health Outcomes and Process Evaluation Research (iHope International, Kyoto, Japan Abstract: Chronic pain is a manifestation of interactions among physical, psychological, and social conditions, but the latter two, that is, the nonphysical correlates of chronic pain, are only rarely measured. This study aimed to develop a profile scoring system for assessing the psychosocial situation of patients with chronic musculoskeletal pain. An expert panel chose social and psychological domains considered to be relevant to patients with chronic pain and wrote questions asking about each of those domains. The questionnaire was completed by 252 patients with chronic musculoskeletal pain. Factor analysis was used to select questionnaire items for each domain. Associations and interactions of pain severity and each domain score with pain-related quality of life (PRQOL were examined using linear regression models. Five domains were chosen: work, family, sleep, mental health, and PRQOL. Then, a total of 17 questions were created for the work, family, and sleep domains. Using the likelihood-ratio test, we found significant interactions with PRQOL in four pairs: severity–family, severity–mental, family–sleep, and work–mental. The association between pain severity and PRQOL was

  1. Diagnosis of pulmonary tuberculosis by score system in children and adolescents: a trial in a reference center in Bahia, Brazil

    Directory of Open Access Journals (Sweden)

    Clemax Couto Sant'Anna

    Full Text Available Since 2002, the Brazilian Ministry of Health has recommended a score system for tuberculosis diagnosis of children and adolescents that does not need bacteriological positivity, because most cases in this age group have few bacteria. An observational, transversal study was carried out at the outpatient health care service of the reference medical service in Salvador, Bahia, including 164 patients with pulmonary tuberculosis, with ages ranging between 1 and 15 years of age, who were treated from 1990 to 2001. The gold standard used to establish the diagnosis was clinical, radiological, epidemiological and based on follow-up data. The score system for diagnosis purposes was tested retrospectively. The median age and the average age of the 164 patients were 6 and 6.62 years (SD ± 4.33, respectively. About 65% of the sample reported a history of close contact with a tuberculous adult. The BCG vaccine coverage was 70.7% (116/164. It was found that 26% (43/164 of the patients had severe malnutrition. Out of this group, 26/43 (60.47% were < 5mm reactive to the tuberculin test. On the other hand, out of the 91 patients with tuberculin test < 5mm, 29% (26/ 91 had severe malnutrition. The use of the score gave the following distribution: a TB very likely in 81.7% (134/164 of the patients; b possible TB in 15.9% (26/164 and TB unlikely in 2.4% (4/164. Among patients who had been vaccinated more than 2 years before, there was a 9 times higher risk of finding a tuberculin test above 10 mm in individuals with probable TB in comparison with the patients with possible or unlikely TB.

  2. Validation of a prediction model that allows direct comparison of the Oxford Knee Score and American Knee Society clinical rating system.

    Science.gov (United States)

    Maempel, J F; Clement, N D; Brenkel, I J; Walmsley, P J

    2015-04-01

    This study demonstrates a significant correlation between the American Knee Society (AKS) Clinical Rating System and the Oxford Knee Score (OKS) and provides a validated prediction tool to estimate score conversion. A total of 1022 patients were prospectively clinically assessed five years after TKR and completed AKS assessments and an OKS questionnaire. Multivariate regression analysis demonstrated significant correlations between OKS and the AKS knee and function scores but a stronger correlation (r = 0.68, p Society of Bone & Joint Surgery.

  3. Designing a Prognostic Scoring System for Predicting the Outcomes of Proximal Fifth Metatarsal Fractures at 20 Weeks

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Tahririan

    2015-03-01

    Full Text Available Background: Fractures of the proximal fifth metatarsal bone are among the most common fractures observed in the foot and their classification and management has been subject to much discussion and disagreement. In this study, we aim to identify and quantify the effect of possible predictors of the outcome of the treatment of proximal fifth metatarsal fractures. Methods: Patients with established proximal fifth metatarsal fractures were enrolled in this prospective cohort and the outcome of their treatment was assessed using the AOFAS mid foot scale at 6 and 20 weeks. Results: 143 patients were included in the study. Our study showed that displacement, weight and type III fractures were significant independent predictors of poor outcome at 6 weeks while at 20 weeks in addition to these factors, gender and diabetes mellitus were also shown to be significant independent predictors of poor outcome. A scoring system was designed by assigning weight to these factors and it was shown to be a strong predictor of outcome at 20 weeks. Conclusion: We recommend that our scoring system would help surgeons to decide whether patients’ prognostic factors are significant enough for him/her to opt for a surgical approach to treatment rather than a conservative approach.

  4. The kidney allocation score: methodological problems, moral concerns and unintended consequences.

    Science.gov (United States)

    Hippen, B

    2009-07-01

    The growing disparity between the demand for and supply of kidneys for transplantation has generated interest in alternative systems of allocating kidneys from deceased donors. This personal viewpoint focuses attention on the Kidney Allocation Score (KAS) proposal promulgated by the UNOS/OPTN Kidney Committee. I identify several methodological and moral flaws in the proposed system, concluding that any iteration of the KAS proposal should be met with more skepticism than sanguinity.

  5. Results of kidney transplantation from high-terminal creatinine donors and the role of time-zero biopsy.

    Science.gov (United States)

    Lin, N C; Yang, A H; King, K L; Wu, T H; Yang, W C; Loong, C C

    2010-11-01

    Deceased-donor kidney transplantation (DDKT) from high-terminal creatinine donors is associated with lower graft survival. These kidneys may be considered for discarding, worsening the organ shortage crisis. Using time-zero biopsy for histologic evaluation of these kidneys, we identified those organs eligible for transplantation, seeking to achieve better graft utility with comparable outcomes. From April 2004 to April 2008, 55 patients underwent DDKT. A time-zero biopsy was used to examine glomerulosclerosis, interstitial fibrosis, tubular atrophy, and arteriolar narrowing. A scoring system was used to determine a discard. Twenty-five patients received DDKT from donors whose terminal creatinine levels were >2.0 mg/dL (high terminal creatinine, HTC group) and 30 from donors whose terminal creatinine levels were creatinine, LTC group). Patients who accepted kidneys from HTC donors had shorter waiting times (P = .011) but a higher incidence of delayed graft function after transplantation (P high-terminal creatinine donors can be transplanted to overcome the organ shortage while achieving reasonable graft survival. Copyright © 2010 Elsevier Inc. All rights reserved.

  6. Quality of life of elderly live kidney donors.

    Science.gov (United States)

    Klop, Karel W J; Dols, Leonienke F C; Weimar, Willem; Dooper, Ine M; IJzermans, Jan N M; Kok, Niels F M

    2013-10-15

    Expanding the use of elderly live donors may help meet the demand for kidney transplants. The aim of this study was to quantify the effect of the surgical procedure on the quality of life (QOL) of elderly donors compared with younger donors. Alongside three prospective studies (two randomized) running between May 2001 and October 2010, we asked 501 live donors to fill out the Short Form-36 questionnaire preoperatively and at 1, 3, 6, and 12 months postoperatively. We defined live donors 60 years or older as elderly. Between-group analyses regarding QOL were adjusted for baseline values and gender. One hundred thirty-five donors were older and 366 donors were younger than 60 years. The response rate was high, with 87% at 12 months postoperatively. Elderly donors less often scored as American Society of Anaesthesiology classification 1 (60% vs. 81%; Pvitality" (5 points; P=0.008). At 3 months, "bodily pain" (3 points, P=0.04) and "role physical" (8 points, P=0.02) were still in favor of the older group. At 6 and 12 months, "physical function" was in favor of the younger group (3 and 5 points, respectively; P=0.04 and P<0.001). This study demonstrates that elderly donors recover relatively fast. The perspective of excellent postoperative QOL may help convince elderly individuals to donate.

  7. Deceleration in maturation of bone during adolescent age in achondroplasia - a retrospective study using RUS scoring system

    International Nuclear Information System (INIS)

    Lee, Suk-Ha; Modi, Hitesh N.; Suh, Seung Woo; Song, Hae-Ryong; Hazra, Sunit; Modi, Chetna

    2009-01-01

    Knowledge of bone age in achondroplasia is required for the prediction of adult height, timings of limb lengthening, and epiphysiodesis procedures. The purpose of this investigation was to determine the differences in skeletal age in achondroplasia and a control population with the Tanner-Whitehouse 3 method using the RUS score and to determine the right age for the interventional procedure for limb lengthening procedure or deformity correction in these patients. Left hand radiographs of 34 patients (age range, 5-18 years) with achondroplasia were evaluated for skeletal age using the RUS scoring system, which were compared with the left hand radiographs of 41 patients (age range, 5-18 years) without achondroplasia measuring skeletal age. The difference in chronological age and RUS bone age were evaluated statistically according to gender and age group. In the achondroplasia group, chronological age were 10.5±4.3 years for males and 10.1±3.6 years for females and RUS bone age were 9.2±4.0 years for males and 8.9±3.4 years for females, which showed statistically significantly difference (males p=0.0003 and females p 10 years in the study group, while 0.1±1.1 for 10 years in the control group, which also showed >statistically significant difference ( 10 years p 10 years in achondroplasia patients compared to nonachondroplasia patients. We recommend the use of the Tanner-Whitehouse 3 method especially the radius, ulna, short bone score to measure the skeletal age and to wait for a longer time before interventional procedures in achondroplasia patients. (orig.)

  8. Implementation of a novel postoperative monitoring system using automated Modified Early Warning Scores (MEWS) incorporating end-tidal capnography.

    Science.gov (United States)

    Blankush, Joseph M; Freeman, Robbie; McIlvaine, Joy; Tran, Trung; Nassani, Stephen; Leitman, I Michael

    2017-10-01

    Modified Early Warning Scores (MEWS) provide real-time vital sign (VS) trending and reduce ICU admissions in post-operative patients. These early warning calculations classically incorporate oxygen saturation, heart rate, respiratory rate, systolic blood pressure, and temperature but have not previously included end-tidal CO2 (EtCO 2 ), more recently identified as an independent predictor of critical illness. These systems may be subject to failure when physiologic data is incorrectly measured, leading to false alarms and increased workload. This study investigates whether the implementation of automated devices that utilize ongoing vital signs monitoring and MEWS calculations, inclusive of a score for end-tidal CO 2 (EtCO 2 ), can be feasibly implemented on the general care hospital floor and effectively identify derangements in a post-operative patient's condition while limiting the amount of false alarms that would serve to increase provider workload. From July to November 2014, post-operative patients meeting the inclusion criteria (BMI > 30 kg/m 2 , history of obstructive sleep apnea, or the use of patient-controlled analgesia (PCA) or epidural narcotics) were monitored using automated devices that record minute-by-minute VS included in classic MEWS calculations as well as EtCO 2 . Automated messages via pagers were sent to providers for instances when the device measured elevated MEWS, abnormal EtCO 2 , and oxygen desaturations below 85 %. Data, including alarm and message details from the first 133 patients, were recorded and analyzed. Overall, 3.3 alarms and pages sounded per hour of monitoring. Device-only alarms sounded 2.7 times per hour-21 % were technical alarms. The remaining device-only alarms for concerning VS sounded 2.0/h, 70 % for falsely recorded VS. Pages for abnormal EtCO 2 sounded 0.4/h (82 % false recordings) while pages for low blood oxygen saturation sounded 0.1/h (55 % false alarms). 143 times (0.1 pages/h) the devices calculated

  9. Development of a profile scoring system for assessing the psychosocial situation of patients with chronic musculoskeletal pain

    Science.gov (United States)

    Nikaido, Takuya; Fukuma, Shingo; Wakita, Takafumi; Sekiguchi, Miho; Yabuki, Shoji; Onishi, Yoshihiro; Fukuhara, Shunichi; Konno, Shin-ichi

    2017-01-01

    Chronic pain is a manifestation of interactions among physical, psychological, and social conditions, but the latter two, that is, the nonphysical correlates of chronic pain, are only rarely measured. This study aimed to develop a profile scoring system for assessing the psychosocial situation of patients with chronic musculoskeletal pain. An expert panel chose social and psychological domains considered to be relevant to patients with chronic pain and wrote questions asking about each of those domains. The questionnaire was completed by 252 patients with chronic musculoskeletal pain. Factor analysis was used to select questionnaire items for each domain. Associations and interactions of pain severity and each domain score with pain-related quality of life (PRQOL) were examined using linear regression models. Five domains were chosen: work, family, sleep, mental health, and PRQOL. Then, a total of 17 questions were created for the work, family, and sleep domains. Using the likelihood-ratio test, we found significant interactions with PRQOL in four pairs: severity–family, severity–mental, family–sleep, and work–mental. The association between pain severity and PRQOL was related to each patient’s social and psychological situation. These results suggest that interventions for patients with chronic pain may be personalized to account for each individual’s psychosocial situation. PMID:28814896

  10. AN OBSERVATIONAL CLINICAL STUDY OF ASSESSING THE UTILITY OF PSS (POISON SEVERITY SCORE AND GCS (GLASGOW COMA SCALE SCORING SYSTEMS IN PREDICTING SEVERITY AND CLINICAL OUTCOMES IN OP POISONING

    Directory of Open Access Journals (Sweden)

    S. Chandrasekhar

    2017-05-01

    Full Text Available BACKGROUND Organophosphorus compound poisoning is the most common poisonings in India because of easy availability often requiring ICU care and ventilator support. Clinical research has indicated that respiratory failure is the most important cause of death due to organophosphorus poisoning. It results in respiratory muscle weakness, pulmonary oedema, respiratory depression, increased secretions and bronchospasm. These complications and death can be prevented with timely institution of ventilator support. MATERIALS AND METHODS Hundred consecutive patients admitted with a history of organophosphorus poisoning at Kurnool Medical College, Kurnool, were taken for study after considering the inclusion and exclusion criteria. Detailed history, confirmation of poisoning, examination and other than routine investigations, serum pseudocholinesterase and arterial blood gas analysis was done. The severity and clinical outcomes in OP poisoning is graded by PSS (poison severity score and GCS (Glasgow coma scale scoring systems. RESULTS This study was conducted in 100 patients with male preponderance. Majority of poisoning occurred in 21-30 age group (n=5. Most common compound consumed in our study was methyl parathion and least common was phosphoran. Slightly more than half of the patients consumed less than 50 mL of poison. 21 patients consumed between 50 to 100 mL. Distribution of poison severity score of patients studied showed 45 cases of grade 1 poisoning. 26 cases of grade 2 poisoning, 23 cases of grade 3 poisoning and 6 cases of grade 4 poisoning (death within first 24 hours. Distribution of GCS score of patients studied GCS scores were <10 in 25 patients at admission and 24 patients after 24 hours. GCS scores were ≥10 in 75 patients at admission and 76 patients after 24 hours. Poison severity score is not prognostic, but merely defines severity of OP poisoning at a given time. CONCLUSION Both Glasgow coma scale and poison severity scoring systems

  11. A scoring system to guide the decision for a new systemic treatment after at least two lines of palliative chemotherapy for metastatic cancers: a prospective study.

    Science.gov (United States)

    Chanez, Brice; Bertucci, François; Gilabert, Marine; Madroszyk, Anne; Rousseau, Frédérique; Perrot, Delphine; Viens, Patrice; Raoul, Jean-Luc

    2017-09-01

    A four-parameter score has been identified as associated with overall survival (OS) in patients with advanced cancer with an estimated survival inferior to 6 months. Here, we tested its prognostic value for OS in patients who had received more than two lines of systemic therapy. We prospectively enrolled patients with advanced cancer who were going to receive a third or more therapeutic line outside classical clinical guidelines. The four parameters (Eastern Cooperative Oncology Group performance status, number of metastatic sites, serum LDH, and serum albumin) were collected at baseline, allowing to calculate the score, which sorted the patients in three groups, A, B, and C (low, intermediate, and high score, respectively). We then searched for correlations between this grouping and clinicopathological features particularly OS. From August 2013 to March 2014, 65 patients were enrolled and corresponded after determining their score to 26 patients in group A, 30 in B, and 9 in C. The median OS of the cohort was 4.4 months, and the 6-month OS was 42%. Overall survival was different between the three groups, with respective 6-month OS equal to 80% in group A, 17% in group B, and 0% in group C and respective median OS of 9, 2.3, and 1.6 months. Such prognostic value persisted in multivariate analysis. Similar OS differences were observed in patients with PS ≤2. This simple scoring should help oncologists identify which patients, after at least two lines of systemic therapy, might benefit from best supportive care alone.

  12. Melanoma maligno cutâneo: sistema de pontos (scoring system para auxílio no diagnóstico histopatológico Cutaneous malignant melanoma: scoring system to assist in the histopathologic diagnosis

    Directory of Open Access Journals (Sweden)

    Luiz Alberto Veronese

    2006-10-01

    Full Text Available INTRODUÇÃO: O diagnóstico histopatológico de algumas lesões melanocíticas pode ser muito difícil, mesmo para especialistas, mas há casos em que a dificuldade surge pela inadequada e subjetiva aplicação dos critérios diagnósticos. OBJETIVO: O objetivo deste estudo é desenvolver um método de aplicação sistemática desses critérios, atribuindo valores para os mais importantes. MATERIAL E MÉTODOS: Selecionaram-se os critérios mais relevantes para o diagnóstico de melanoma, atribuindo valores de 1 a 5 de acordo com sua importância. Foram escolhidos 101 casos de melanomas de tipo extensivo-superficial com menos de 2mm de espessura para análise comparativa com 33 lesões melanocíticas benignas (13 nevos de Spitz, seis de Reed, seis displásicos, três congênitos, três adquiridos, um combinado e um recorrente. RESULTADOS: A soma dos valores dados aos critérios (score apresentou diferença significativa entre lesões malignas e benignas, mostrando que esse método pode ser útil ao patologista cirúrgico generalista em sua rotina diária. CONCLUSÃO: A aplicação objetiva e sistemática dos critérios histopatológicos pelo sistema de pontos (scoring system pode ajudar o diagnóstico diferencial entre maligno e benigno em muitas lesões, porém não tendo o efeito desejado nas lesões melanocíticas de comportamento biológico indeterminado.INTRODUCTION: The histopathological diagnosis of melanocytic lesions may be very difficult, even by experts within the field. The challenge can come from inaccurate and/or subjective application of the diagnosis criteria. AIM: The goal of this study was to develop a method of systematic application of histopathological criteria as a result of the most relevant microscopic characteristics. MATERIAL AND METHODS: The most important criteria to diagnosing melanoma on histopathological bases were selected and given points ranging from 1 to 5 according to their relevance to the melanoma diagnosis

  13. Another Look at the PART-O Using the Traumatic Brain Injury Model Systems National Database: Scoring to Optimize Psychometrics.

    Science.gov (United States)

    Malec, James F; Whiteneck, Gale G; Bogner, Jennifer A

    2016-02-01

    To integrate previous approaches to scoring the Participation Assessment with Recombined Tools-Objective (PART-O) in a unidimensional scale. Retrospective analysis of PART-O data from the Traumatic Brain Injury Model Systems. Community. Data from individuals (N=469) selected randomly from participants who completed 1-year follow-up in the Traumatic Brain Injury Model Systems were used in Rasch model development. The model was subsequently tested on data from additional random samples of similar size at 1-, 2-, 5-, 10-, and >15-year follow-ups. Not applicable. PART-O. After combining items for productivity and social interaction, the initial analysis at 1-year follow-up indicated relatively good fit to the Rasch model (person reliability=.80) but also suggested item misfit and that the 0-to-5 scale used for most items did not consistently show clear separation between rating levels. Reducing item rating scales to 3 levels (except combined and dichotomous items) resolved these issues and demonstrated good item level discrimination, fit, and person reliability (.81), with no evidence of multidimensionality. These results replicated in analyses at each additional follow-up period. Modifications to item scoring for the PART-O resulted in a unidimensional parametric equivalent measure that addresses previous concerns about competing item relations, and it fit the Rasch model consistently across follow-up periods. The person-item map shows a progression toward greater community participation from solitary and dyadic activities, such as leaving the house and having a friend through social and productivity activities, to group activities with others who share interests or beliefs. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  14. Effects of breed and feeding system on milk production, body weight, body condition score, reproductive performance, and postpartum ovarian function.

    Science.gov (United States)

    Walsh, S; Buckley, F; Pierce, K; Byrne, N; Patton, J; Dillon, P

    2008-11-01

    The objective of this study was to investigate the potential differences among Holstein-Friesian (HF), Montbéliarde (MB), Normande (NM), Norwegian Red (NRF), Montbéliarde x Holstein-Friesian (MBX), and Normande x Holstein-Friesian (NMX) across 2 seasonal grass-based systems of milk production. The effects of breed and feeding system on milk production, body weight, body condition score, fertility performance, hormone parameters, ovarian function, and survival were determined by using mixed model methodology, generalized linear models, and survival analysis. The 5-yr study comprised up to 749 lactations on 309 cows in one research herd. The HF produced the greatest yield of solids-corrected milk, the MB and NM produced the least yields, and NRF, MBX, and NMX were in