WorldWideScience

Sample records for divertor heat flux

  1. Divertor heat flux mitigation in the National Spherical Torus Experimenta)

    Science.gov (United States)

    Soukhanovskii, V. A.; Maingi, R.; Gates, D. A.; Menard, J. E.; Paul, S. F.; Raman, R.; Roquemore, A. L.; Bell, M. G.; Bell, R. E.; Boedo, J. A.; Bush, C. E.; Kaita, R.; Kugel, H. W.; Leblanc, B. P.; Mueller, D.; NSTX Team

    2009-02-01

    Steady-state handling of divertor heat flux is a critical issue for both ITER and spherical torus-based devices with compact high power density divertors. Significant reduction of heat flux to the divertor plate has been achieved simultaneously with favorable core and pedestal confinement and stability properties in a highly shaped lower single null configuration in the National Spherical Torus Experiment (NSTX) [M. Ono et al., Nucl. Fusion 40, 557 2000] using high magnetic flux expansion at the divertor strike point and the radiative divertor technique. A partial detachment of the outer strike point was achieved with divertor deuterium injection leading to peak flux reduction from 4-6MWm-2to0.5-2MWm-2 in small-ELM 0.8-1.0MA, 4-6MW neutral beam injection-heated H-mode discharges. A self-consistent picture of the outer strike point partial detachment was evident from divertor heat flux profiles and recombination, particle flux and neutral pressure measurements. Analytic scrape-off layer parallel transport models were used for interpretation of NSTX detachment experiments. The modeling showed that the observed peak heat flux reduction and detachment are possible with high radiated power and momentum loss fractions, achievable with divertor gas injection, and nearly impossible to achieve with main electron density, divertor neutral density or recombination increases alone.

  2. The comparison of heat flux pattern on lower divertor in KSTAR

    International Nuclear Information System (INIS)

    Bang, Eunnam; Hong, Suk-Ho; Bak, JunGyo; Kim, Kyungmin; Kim, Hongtack; Kim, Hakkun; Yang, H.L.

    2015-01-01

    Highlights: • The heat flux on the lower divertor is higher than upper divertor. • The heat flux on OD is decreased with IVCP. • The heat flux on CD is decreased with RMP, but that on OD is increased. • Because the strike point was shifted from CD toward OD due to the RMP. - Abstract: The heat flux in KSTAR is estimated for various discharge conditions by using thermocouple arrays. The heat flux on the divertor is higher than that on inboard limiter or passive stabilizer by a factor of 2. Although the plasma configuration in KSTAR has been set to a double-null configuration, the heat flux on lower divertor is higher than that on upper divertor by 3–8 times, indicating a lower-single-null-like configuration. It is observed that the operation of the in-vessel cryo-pump (IVCP) changes the heat flux pattern significantly: When the IVCP was not operated, the heat fluxes on inboard divertor (ID), central divertor (CD) and outboard divertor (OD) were similar, but when the IVCP was operated, the heat fluxes on ID and CD were increased slightly and that on OD was decreased by 2–3 times. The heat flux on divertor was decreased from 35 to 26 kW/m"2 with the use of the resonant magnetic perturbation (RMP), especially that on CD was decreased by 2–4 times, while that on OD is increased by 2–3 times than without RMP. For the longest H-mode pulse of 22 s shot, the heat flux on lower OD was 73 kW/m"2, which is the maximum heat flux among the shots obtained in 2013 campaign.

  3. Divertor heat flux control and plasma-material interaction

    International Nuclear Information System (INIS)

    Kikuchi, Yusuke; Nagata, Masayoshi; Sawada, Keiji; Takamura, Shuichi; Ueda, Yoshio

    2014-01-01

    Development of reliable radiative-cooling divertors is essential in DEMO reactor because it uses low-activation materials with low heat removal and the plasma heat flux exhausted from the confined region is 5 times as large as in ITER. It is important to predict precisely the heat and particle flux toward the divertor plate by simulation. In this present article, theoretical and experimental data of the reflection, secondary emission and surface recombination coefficients of the divertor plate by ion bombardment are given and their effects on the power transmission coefficient are discussed. In addition, some topics such as the erosion process of the divertor plate by ELM and the plasma disruption, the thermal shielding due to the vapor layer on the divertor plate and the formation of fuzz structure on W by helium plasma irradiation, are described. (author)

  4. Heat flux management via advanced magnetic divertor configurations and divertor detachment

    Energy Technology Data Exchange (ETDEWEB)

    Kolemen, E., E-mail: ekolemen@princeton.edu [Princeton University, Princeton, NJ 08544 (United States); Allen, S.L. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Bray, B.D. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Fenstermacher, M.E. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Humphreys, D.A.; Hyatt, A.W. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Lasnier, C.J. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Leonard, A.W. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Makowski, M.A.; McLean, A.G. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Maingi, R.; Nazikian, R. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Petrie, T.W. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Soukhanovskii, V.A. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Unterberg, E.A. [Oak Ridge National Laboratory, PO Box 2008, Oak Ridge, TN 37831 (United States)

    2015-08-15

    The snowflake divertor (SFD) control and detachment control to manage the heat flux at the divertor are successfully demonstrated at DIII-D. Results of the development and implementation of these two heat flux reduction control methods are presented. The SFD control algorithm calculates the position of the two null-points in real-time and controls shaping coil currents to achieve and stabilize various snowflake configurations. Detachment control stabilizes the detachment front fixed at specified distance between the strike point and the X-point throughout the shot.

  5. Estimation of peak heat flux onto the targets for CFETR with extended divertor leg

    International Nuclear Information System (INIS)

    Zhang, Chuanjia; Chen, Bin; Xing, Zhe; Wu, Haosheng; Mao, Shifeng; Luo, Zhengping; Peng, Xuebing; Ye, Minyou

    2016-01-01

    Highlights: • A hypothetical geometry is assumed to extend the outer divertor leg in CFETR. • Density scan SOLPS simulation is done to study the peak heat flux onto target. • Attached–detached regime transition in out divertor occurs at lower puffing rate. • Unexpected delay of attached–detached regime transition occurs in inner divertor. - Abstract: China Fusion Engineering Test Reactor (CFETR) is now in conceptual design phase. CFETR is proposed as a good complement to ITER for demonstrating of fusion energy. Divertor is a crucial component which faces the plasmas and handles huge heat power for CFETR and future fusion reactor. To explore an effective way for heat exhaust, various methods to reduce the heat flux to divertor target should be considered for CFETR. In this work, the effect of extended out divertor leg on the peak heat flux is studied. The magnetic configuration of the long leg divertor is obtained by EFIT and Tokamak Simulation Code (TSC), while a hypothetical geometry is assumed to extend the out divertor leg as long as possible inside vacuum vessel. A SOLPS simulation is performed to study peak heat flux of the long leg divertor for CFETR. D 2 gas puffing is used and increasing of the puffing rate means increase of plasma density. Both peak heat flux onto inner and outer targets are below 10 MW/m 2 is achieved. A comparison between the peak heat flux between long leg and conventional divertor shows that an attached–detached regime transition of out divertor occurs at lower gas puffing gas puffing rate for long leg divertor. While for the inner divertor, even the configuration is almost the same, the situation is opposite.

  6. Estimation of peak heat flux onto the targets for CFETR with extended divertor leg

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chuanjia; Chen, Bin [School of Nuclear Science and Technology, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui 230026 (China); Xing, Zhe [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Wu, Haosheng [School of Nuclear Science and Technology, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui 230026 (China); Mao, Shifeng, E-mail: sfmao@ustc.edu.cn [School of Nuclear Science and Technology, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui 230026 (China); Luo, Zhengping; Peng, Xuebing [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Ye, Minyou [School of Nuclear Science and Technology, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui 230026 (China); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China)

    2016-11-01

    Highlights: • A hypothetical geometry is assumed to extend the outer divertor leg in CFETR. • Density scan SOLPS simulation is done to study the peak heat flux onto target. • Attached–detached regime transition in out divertor occurs at lower puffing rate. • Unexpected delay of attached–detached regime transition occurs in inner divertor. - Abstract: China Fusion Engineering Test Reactor (CFETR) is now in conceptual design phase. CFETR is proposed as a good complement to ITER for demonstrating of fusion energy. Divertor is a crucial component which faces the plasmas and handles huge heat power for CFETR and future fusion reactor. To explore an effective way for heat exhaust, various methods to reduce the heat flux to divertor target should be considered for CFETR. In this work, the effect of extended out divertor leg on the peak heat flux is studied. The magnetic configuration of the long leg divertor is obtained by EFIT and Tokamak Simulation Code (TSC), while a hypothetical geometry is assumed to extend the out divertor leg as long as possible inside vacuum vessel. A SOLPS simulation is performed to study peak heat flux of the long leg divertor for CFETR. D{sub 2} gas puffing is used and increasing of the puffing rate means increase of plasma density. Both peak heat flux onto inner and outer targets are below 10 MW/m{sup 2} is achieved. A comparison between the peak heat flux between long leg and conventional divertor shows that an attached–detached regime transition of out divertor occurs at lower gas puffing gas puffing rate for long leg divertor. While for the inner divertor, even the configuration is almost the same, the situation is opposite.

  7. Innovative Divertor Development to Solve the Plasma Heat-Flux Problem

    International Nuclear Information System (INIS)

    Rognlien, T.; Ryutov, D.; Makowski, M.; Soukhanovskii, V.; Umansky, M.; Cohen, R.; Hill, D.; Joseph, I.

    2009-01-01

    Large, localized plasma heat exhaust continues to be one of the critical problems for the development of tokamak fusion reactors. Excessive heat flux erodes and possibly melts plasma-facing materials, thereby dramatically shortening their lifetime and increasing the impurity contamination of the core plasma. A detailed assessment by the ITER team for their divertor has revealed substantial limitations on the operational space imposed by the divertor performance. For a fusion reactor, the problem becomes worse in that the divertor must accommodate 20% of the total fusion power (less any broadly radiated loss), while not allowing excess buildup of tritium in the walls nor excessive impurity production. This is an extremely challenging set of problems that must be solved for fusion to succeed as a power source; it deserves a substantial research investment. Material heat-flux constraints: Results from present-day tokamaks show that there are two major limitations of peak plasma heat exhaust. The first is the continuous flow of power to the divertor plates and nearby surfaces that, for present technology, is limited to 10-20 MW/m 2 . The second is the transient peak heat-flux that can be tolerated in a short time, τ m , before substantial ablation and melting of the surface occurs; such common large transient events are Edge Localized Mode (ELMs) and disruptions. The material limits imposed by these events give a peak energy/τ m 1/2 parameter of ∼ 40 MJ/m 2 s 1/2 (1). Both the continuous and transient limits can be approached by input powers in the largest present-day devices, and future devices are expected to substantially exceed the limits unless a solution can be found. Since the early 90's LLNL has developed the analytic and computational foundation for analyzing divertor plasmas, and also suggested and studied a number of solid and liquid material concepts for improving divertor/wall performance, with the most recent being the Snowflake divertor concept (2

  8. Active control of divertor heat and particle fluxes in EAST towards advanced steady state operations

    Energy Technology Data Exchange (ETDEWEB)

    Wang, L., E-mail: lwang@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Dalian University of Technology, Dalian 116024 (China); Guo, H.Y. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); General Atomics, P. O. Box 85608, San Diego, CA 92186 (United States); Li, J.; Wan, B.N.; Gong, X.Z.; Zhang, X.D.; Hu, J.S. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Liang, Y. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Association EURATOM-FZJ, D-52425 Jülich (Germany); Xu, G.S. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Zou, X.L. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Loarte, A. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France); Maingi, R.; Menard, J.E. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Luo, G.N.; Gao, X.; Hu, L.Q.; Gan, K.F.; Liu, S.C.; Wang, H.Q.; Chen, R. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); and others

    2015-08-15

    Significant progress has been made in EAST towards advanced steady state operations by active control of divertor heat and particle fluxes. Many innovative techniques have been developed to mitigate transient ELM and stationary heat fluxes on the divertor target plates. It has been found that lower hybrid current drive (LHCD) can lead to edge plasma ergodization, striation of the stationary heat flux and lower ELM transient heat and particle fluxes. With multi-pulse supersonic molecular beam injection (SMBI) to quantitatively regulate the divertor particle flux, the divertor power footprint pattern can be actively modified. H-modes have been extended over 30 s in EAST with the divertor peak heat flux and the target temperature being controlled well below 2 MW/m{sup 2} and 250 °C, respectively, by integrating these new methods, coupled with advanced lithium wall conditioning and internal divertor pumping, along with an edge coherent mode to provide continuous particle and power exhaust.

  9. Divertor Heat Flux Reduction and Detachment in the National Spherical Torus eXperiment.

    Science.gov (United States)

    Soukhanovskii, Vsevolod

    2007-11-01

    Steady-state handling of the heat flux is a critical divertor issue for both the International Thermonuclear Experimental Reactor and spherical torus (ST) devices. Because of an inherently compact divertor, it was thought that ST-based devices might not be able to fully utilize radiative and dissipative divertor techniques based on induced power and momentum loss. However, initial experiments conducted in the National Spherical Torus Experiment in an open geometry horizontal carbon plate divertor using 0.8 MA 2-6 MW NBI-heated lower single null H-mode plasmas at the lower end of elongations κ=1.8-2.4 and triangularities δ=0.45-0.75 demonstrated that high divertor peak heat fluxes, up to 6-10 MW/ m^2, could be reduced by 50-75% using a high-recycling radiative divertor regime with D2 injection. Furthermore, similar reduction was obtained with a partially detached divertor (PDD) at high D2 injection rates, however, it was accompanied by an X-point MARFE that quickly led to confinement degradation. Another approach takes advantage of the ST relation between strong shaping and high performance, and utilizes the poloidal magnetic flux expansion in the divertor region. Up to 60 % reduction in divertor peak heat flux was achieved at similar levels of scrape-off layer power by varying plasma shaping and thereby increasing the outer strike point (OSP) poloidal flux expansion from 4-6 to 18-22. In recent experiments conducted in highly-shaped 1.0-1.2 MA 6 MW NBI heated H-mode plasmas with divertor D2 injection at rates up to 10^22 s-1, a PDD regime with OSP peak heat flux 0.5-1.5 MW/m^2 was obtained without noticeable confinement degradation. Calculations based on a two point scrape-off layer model with parameterized power and momentum losses show that the short parallel connection length at the OSP sets the upper limit on the radiative exhaust channel, and both the impurity radiation and large momentum sink achievable only at high divertor neutral pressures are required

  10. High heat flux tests of mock-ups for ITER divertor application

    International Nuclear Information System (INIS)

    Giniatulin, R.; Gervash, A.; Komarov, V.L.; Makhankov, A.; Mazul, I.; Litunovsky, N.; Yablokov, N.

    1998-01-01

    One of the most difficult tasks in fusion reactor development is the designing, fabrication and high heat flux testing of actively cooled plasma facing components (PFCs). At present, for the ITER divertor project it is necessary to design and test components by using mock-ups which reflect the real design and fabrication technology. The cause of failure of the PFCs is likely to be through thermo-cycling of the surface with heat loads in the range 1-15 MW m -2 . Beryllium, tungsten and graphite are considered as the most suitable armour materials for the ITER divertor application. This work presents the results of the tests carried out with divertor mock-ups clad with beryllium and tungsten armour materials. The tests were carried out in an electron beam facility. The results of high heat flux screening tests and thermo-cycling tests in the heat load range 1-9 MW m -2 are presented along with the results of metallographic analysis carried out after the tests. (orig.)

  11. High heat flux thermal-hydraulic analysis of ITER divertor and blanket systems

    International Nuclear Information System (INIS)

    Raffray, A.R.; Chiocchio, S.; Ioki, K.; Tivey, R.; Krassovski, D.; Kubik, D.

    1998-01-01

    Three separate cooling systems are used for the divertor and blanket components, based mainly on flow routing access and on grouping together components with the highest heat load levels and uncertainties: divertor, limiter/outboard baffle, and primary first wall/inboard baffle. The coolant parameters for these systems are set to accommodate peak heat load conditions with a reasonable critical heat flux (CHF) margin. Material temperature constraints and heat transport system space and cost requirements are also taken into consideration. This paper summarises the three cooling system designs and highlights the high heat flux thermal-hydraulic analysis carried out in converging on the design values for the coolant operating parameters. Application of results from on-going high heat flux R and D and a brief description of future R and D effort to address remaining issues are also included. (orig.)

  12. Divertor Heat Flux Reduction by Resonant Magnetic Perturbations in the LHD-Type Helical DEMO Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Yanagi, N.; Sagara, A.; Goto, T.; Masuzaki, S.; Miyazawa, J., E-mail: yanagi@lhd.nifs.ac.jp [National Institute for Fusion Science, Toki (Japan)

    2012-09-15

    Full text: The conceptual design studies of the LHD-type helical fusion DEMO reactor, FFHR-d1, are progressing steadfastly. The LHD-type heliotron magnetic configuration equipped with the built- in helical divertors has a potential to realize low divertor heat flux in spatial average. However, the toroidal asymmetry may give more than a couple of times higher peak heat flux at some locations, as has been experimentally observed in LHD and confirmed by magnetic field-line tracing. By providing radiation dispersion accompanied with a plasma detachment, the heat flux may decrease significantly though the compatibility with a good core plasma confinement is an important issue to be explored. Whereas the engineering difficulties for developing materials to be used under the neutron environment require even further decrease of the heat flux (even though the heliotron is a unique configuration that divertor plates be largely shielded from the direct irradiation of neutrons by breeder blankets). In this respect, we proposed, in the last IAEA FEC, a new strike point sweeping scheme using a set of auxiliary helical coils, termed helical divertor (HD) coils. The HD coils carrying a few percent of the current amplitude of the main helical coils sweep the divertor strike points without altering the core plasma. Though this scheme is effective in dispersing the heat flux in the poloidal direction, the toroidal asymmetry still remains. The AC operation may also give unforeseen engineering difficulties. We here propose that the peak heat flux be mitigated using RMP fields in steady-state. The magnetic field-lines are numerically traced in the vacuum configuration and their footprints coming to the divertor regions are counted. Their fraction plotted as a function of the toroidal angle indicates that the peak heat flux be mitigated to {approx} 20 MW per square meters at 3 GW fusion power generation without having radiation dispersion when an RMP field is applied. We note that the

  13. D III-D divertor target heat flux measurements during Ohmic and neutral beam heating

    International Nuclear Information System (INIS)

    Hill, D.N.; Petrie, T.; Mahdavi, M.A.; Lao, L.; Howl, W.

    1988-01-01

    Time resolved power deposition profiles on the D III-D divertor target plates have been measured for Ohmic and neutral beam injection heated plasmas using fast response infrared thermography (τ ≤ 150 μs). Giant Edge Localized Modes have been observed which punctuate quiescent periods of good H-mode confinement and deposit more than 5% of the stored energy of the core plasma on the divertor armour tiles on millisecond time-scales. The heat pulse associated with these events arrives approximately 0.5 ms earlier on the outer leg of the divertor relative to the inner leg. The measured power deposition profiles are displaced relative to the separatrix intercepts on the target plates, and the peak heat fluxes are a function of core plasma density. (author). Letter-to-the-editor. 11 refs, 7 figs

  14. Advanced divertor configurations with large flux expansion

    Energy Technology Data Exchange (ETDEWEB)

    Soukhanovskii, V.A., E-mail: vlad@llnl.gov [Lawrence Livermore National Laboratory, Livermore, CA (United States); Bell, R.E.; Diallo, A.; Gerhardt, S.; Kaye, S.; Kolemen, E.; LeBlanc, B.P. [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); McLean, A. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Menard, J.E.; Paul, S.F.; Podesta, M. [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Raman, R. [University of Washington, Seattle, WA (United States); Ryutov, D.D. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Scotti, F.; Kaita, R. [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Maingi, R. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Mueller, D.M.; Roquemore, A.L. [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Reimerdes, H.; Canal, G.P. [Ecole Polytechnique Fédérale de Lausanne, Centre de Recherches en Physique des Plasmas, Association Euratom Confédération Suisse, Lausanne (Switzerland); and others

    2013-07-15

    Experimental studies of the novel snowflake divertor concept (D. Ryutov, Phys. Plasmas 14 (2007) 064502) performed in the NSTX and TCV tokamaks are reviewed in this paper. The snowflake divertor enables power sharing between divertor strike points, as well as the divertor plasma-wetted area, effective connection length and divertor volumetric power loss to increase beyond those in the standard divertor, potentially reducing heat flux and plasma temperature at the target. It also enables higher magnetic shear inside the separatrix, potentially affecting pedestal MHD stability. Experimental results from NSTX and TCV confirm the predicted properties of the snowflake divertor. In the NSTX, a large spherical tokamak with a compact divertor and lithium-coated graphite plasma-facing components (PFCs), the snowflake divertor operation led to reduced core and pedestal impurity concentration, as well as re-appearance of Type I ELMs that were suppressed in standard divertor H-mode discharges. In the divertor, an otherwise inaccessible partial detachment of the outer strike point with an up to 50% increase in divertor radiation and a peak divertor heat flux reduction from 3–7 MW/m{sup 2} to 0.5–1 MW/m{sup 2} was achieved. Impulsive heat fluxes due to Type-I ELMs were significantly dissipated in the high magnetic flux expansion region. In the TCV, a medium-size tokamak with graphite PFCs, several advantageous snowflake divertor features (cf. the standard divertor) have been demonstrated: an unchanged L–H power threshold, enhanced stability of the peeling–ballooning modes in the pedestal region (and generally an extended second stability region), as well as an H-mode pedestal regime with reduced (×2–3) Type I ELM frequency and slightly increased (20–30%) normalized ELM energy, resulting in a favorable average energy loss comparison to the standard divertor. In the divertor, ELM power partitioning between snowflake divertor strike points was demonstrated. The NSTX

  15. Characteristics of heat flux and particle flux to the divertor in H-mode of JT-60U

    International Nuclear Information System (INIS)

    Itami, K.; Hosogane, N.; Asakura, N.; Kubo, H.; Tsuji, S.; Shimada, M.

    1995-01-01

    Heat flux and particle flux behavior in H-mode is studied in a comparative manner. It was confirmed that the multiple peak structure of heat flux during ELM activity has a role in reducing the average value of a peak heat flux at the divertor. In order to characterize heat and particle flux during ELM activity, the ELM part and the steady state part of heat flux and particle flux were determined and statistically analyzed. A large in-out asymmetry of peak ELM heat flux density was found. The asymmetry is almost unaffected by the ion grad-B drift direction. In-out asymmetry of both ELM and steady-state parts of the particle flux were found to be similar. ((orig.))

  16. Scaling of divertor heat flux profile widths in DIII-D

    International Nuclear Information System (INIS)

    Lasnier, C.J.; Makowski, M.A.; Boedo, J.A.; Allen, S.L.; Brooks, N.H.; Hill, D.N.; Leonard, A.W.; Watkins, J.G.; West, W.P.

    2011-01-01

    New scalings of the dependence of divertor heat flux peak and profile width, important parameters for the design of future large tokamaks, have been obtained from recent DIII-D experiments. We find the peak heat flux depends linearly on input power, decreases linearly with increasing density, and increases linearly with plasma current. The profile width has a weak dependence on input power, is independent of density up to the onset of detachment, and is inversely proportional to the plasma current. We compare these results with previously published scalings, and present mathematical expressions incorporating these results.

  17. Kinetic modeling of divertor heat load fluxes in the Alcator C-Mod and DIII-D tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Pankin, A. Y. [Tech-X Corporation, Boulder, Colorado 80303 (United States); Rafiq, T.; Kritz, A. H. [Department of Physics, Lehigh University, Bethlehem, Pennsylvania 18015 (United States); Park, G. Y. [National Fusion Research Institute, Daejeon, 305-333 (Korea, Republic of); Chang, C. S.; Ku, S. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540 (United States); Brunner, D.; Hughes, J. W.; LaBombard, B.; Terry, J. L. [MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139 (United States); Groebner, R. J. [General Atomics, San Diego, California 92121 (United States)

    2015-09-15

    The guiding-center kinetic neoclassical transport code, XGC0 [Chang et al., Phys. Plasmas 11, 2649 (2004)], is used to compute the heat fluxes and the heat-load width in the outer divertor plates of Alcator C-Mod and DIII-D tokamaks. The dependence of the width of heat-load fluxes on neoclassical effects, neutral collisions, and anomalous transport is investigated using the XGC0 code. The XGC0 code includes realistic X-point geometry, a neutral source model, the effects of collisions, and a diffusion model for anomalous transport. It is observed that the width of the XGC0 neoclassical heat-load is approximately inversely proportional to the total plasma current I{sub p.} The scaling of the width of the divertor heat-load with plasma current is examined for an Alcator C-Mod discharge and four DIII-D discharges. The scaling of the divertor heat-load width with plasma current is found to be weaker in the Alcator C-Mod discharge compared to scaling found in the DIII-D discharges. The effect of neutral collisions on the 1/I{sub p} scaling of heat-load width is shown not to be significant. Although inclusion of poloidally uniform anomalous transport results in a deviation from the 1/I{sub p} scaling, the inclusion of the anomalous transport that is driven by ballooning-type instabilities results in recovering the neoclassical 1/I{sub p} scaling. The Bohm or gyro-Bohm scalings of anomalous transport do not strongly affect the dependence of the heat-load width on plasma current. The inclusion of anomalous transport, in general, results in widening the width of neoclassical divertor heat-load and enhances the neoclassical heat-load fluxes on the divertor plates. Understanding heat transport in the tokamak scrape-off layer plasmas is important for strengthening the basis for predicting divertor conditions in ITER.

  18. Impact of ELM filaments on divertor heat flux dynamics in NSTX

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, J.-W., E-mail: jahn@pppl.gov [Oak Ridge National Laboratory, Oak Ridge (United States); Maingi, R. [Princeton Plasma Physics Laboratory, Princeton (United States); Canik, J.M. [Oak Ridge National Laboratory, Oak Ridge (United States); Gan, K.F. [Institute of Plasma Physics, Chinese Academy of Science, Hefei (China); Gray, T.K. [Oak Ridge National Laboratory, Oak Ridge (United States); McLean, A.G. [Lawrence Livermore National Laboratory, Livermore (United States)

    2015-08-15

    The ELM induced change in wetted area (A{sub wet}) and peak heat flux (q{sub peak}) of divertor heat flux is investigated as a function of the number of striations, which represent ELM filaments, observed in the heat flux profile in NSTX. More striations are found to lead to larger A{sub wet} and lower q{sub peak}. The typical number of striations observed in NSTX is 0–9, while 10–15 striations are normally observed in other machines such as JET, and the ELM contracts heat flux profile when the number of striations is less than 3–4 but broadens it with more of them. The smaller number of striations in NSTX is attributed to the fact that NSTX ELMs are against kink/peeling boundary with lower toroidal mode number (n = 1–5), while typical peeling–ballooning ELMs have higher mode number of n = 10–20. For ELMs with smaller number of striations, relative A{sub wet} change is rather constant and q{sub peak} change rapidly increases with increasing ELM size, while A{sub wet} change slightly increases leading to a weaker increase of q{sub peak} change for ELMs with larger number of striations, both of which are unfavourable trend for the material integrity of divertor tiles.

  19. Combination of helical ferritic-steel inserts and flux-tube-expansion divertor for the heat control in tokamak DEMO reactor

    International Nuclear Information System (INIS)

    Takizuka, T.; Tokunaga, S.; Hoshino, K.; Shimizu, K.; Asakura, N.

    2015-01-01

    Edge localized modes (ELMs) in the H-mode operation of tokamak reactors may be suppressed/mitigated by the resonant magnetic perturbation (RMP), but RMP coils are considered incompatible with DEMO reactors under the strong neutron flux. We propose an innovative concept of the RMP without installing coils but inserting ferritic steels of the helical configuration. Helically perturbed field is naturally formed in the axisymmetric toroidal field through the helical ferritic steel inserts (FSIs). When ELMs are avoided, large stationary heat load on divertor plates can be reduced by adopting a flux-tube-expansion (FTE) divertor like an X divertor. Separatrix shape and divertor-plate inclination are similar to those of a simple long-leg divertor configuration. Combination of the helical FSIs and the FTE divertor is a suitable method for the heat control to avoid transient ELM heat pulse and to reduce stationary divertor heat load in a tokamak DEMO reactor

  20. Feedback system for divertor impurity seeding based on real-time measurements of surface heat flux in the Alcator C-Mod tokamak

    Science.gov (United States)

    Brunner, D.; Burke, W.; Kuang, A. Q.; LaBombard, B.; Lipschultz, B.; Wolfe, S.

    2016-02-01

    Mitigation of the intense heat flux to the divertor is one of the outstanding problems in fusion energy. One technique that has shown promise is impurity seeding, i.e., the injection of low-Z gaseous impurities (typically N2 or Ne) to radiate and dissipate the power before it arrives to the divertor target plate. To this end, the Alcator C-Mod team has created a first-of-its-kind feedback system to control the injection of seed gas based on real-time surface heat flux measurements. Surface thermocouples provide real-time measurements of the surface temperature response to the plasma heat flux. The surface temperature measurements are inputted into an analog computer that "solves" the 1-D heat transport equation to deliver accurate, real-time signals of the surface heat flux. The surface heat flux signals are sent to the C-Mod digital plasma control system, which uses a proportional-integral-derivative (PID) algorithm to control the duty cycle demand to a pulse width modulated piezo valve, which in turn controls the injection of gas into the private flux region of the C-Mod divertor. This paper presents the design and implementation of this new feedback system as well as initial results using it to control divertor heat flux.

  1. Analysis of sweeping heat loads on divertor plate materials

    International Nuclear Information System (INIS)

    Hassanein, A.

    1991-01-01

    The heat flux on the divertor plate of a fusion reactor is probably one of the most limiting constraints on its lifetime. The current heat flux profile on the outer divertor plate of a device like ITER is highly peaked with narrow profile. The peak heat flux can be as high as 30--40 MW/m 2 with full width at half maximum (FWHM) is in the order of a few centimeters. Sweeping the separatrix along the divertor plate is one of the options proposed to reduce the thermomechanical effects of this highly peaked narrow profile distribution. The effectiveness of the sweeping process is investigated parametrically for various design values. The optimum sweeping parameters of a particular heat load will depend on the design of the divertor plate as well as on the profile of such a heat load. In general, moving a highly peaked heat load results in substantial reduction of the thermomechanical effects on the divertor plate. 3 refs., 8 figs

  2. Critical heat flux analysis and R and D for the design of the ITER divertor

    International Nuclear Information System (INIS)

    Raffray, A.R.; Chiocchio, S.; Merola, M.; Tivey, R.; Vieider, G.; Schlosser, J.; Driemeyer, D.; Escourbiac, F.; Grigoriev, S.; Youchison, D.

    1999-01-01

    The vertical target and dump target of the ITER divertor have to be designed for high heat fluxes (up to 20 MW/m 2 over ∼10 s). Accommodation of such high heat fluxes gives rise to several issues, including the critical heat flux (CHF) margin which is a key requirement influencing the choice of cooling channel geometry and coolant conditions. An R and D programme was evolved to address the overall CHF issue and to help focus the design. It involved participation of the four ITER home teams and has been very successful in substantially expanding the CHF data base for one-sided heating and in providing more accurate experimental measurements of pressure drop (and derived correlations) for these geometries. This paper describes the major R and D results and the design analysis performed in converging on a choice of reference configuration and parameters which resulted in a CHF margin of ∼1.4 or more for all divertor components. (orig.)

  3. High heat flux testing of EU tungsten monoblock mock-ups for the ITER divertor

    International Nuclear Information System (INIS)

    Gavila, P.; Riccardi, B.; Pintsuk, G.; Ritz, G.; Kuznetsov, V.; Durocher, A.

    2015-01-01

    Highlights: • All the tested items sustained the ITER Full W divertor qualification program requirements. This confirms that the technology for the manufacturing of the first set of the ITER Divertor is available in Europe. • The surface roughening and local melting of the W surface under high heat flux was proven to be significantly reduced for an armour thickness lower or equal to 6 mm. • However, this campaign highlighted some specific areas of improvement to be implemented ideally before the upcoming ITER Divertor IVT serial production. • The issue of the self-castellation of the W monoblocks, which typically appears after a few tenths of cycles at 20 MW/m"2, is critical because it generates some uncontrolled defects at the amour to heat sink joints. Besides, they create a gap which exposure is almost perpendicular to the magnetic field lines and which might lead to local W melting in the strike point region. • This campaign also evidenced that the minimum IO requirements on the CuCrZr ductility could be revised to avoid the occurrence of rather early fatigue failures. Although the W material characterization program has been set up by the IO, the strategy on the CuCrZr still needs to be defined. - Abstract: With the aim to assess the option to start the ITER operation with a full tungsten divertor, an R&D program was launched in order to evaluate the performances of tungsten (W) armoured plasma facing components (PFCs) under high heat flux. The F4E program consisted in the manufacturing and high heat flux (HHF) testing of W monoblock mock-ups and medium scale prototypes up to 20 MW/m"2. During the test campaign, 26 W mock-ups and two medium scale prototypes manufactured by Plansee SE (Austria) and by Ansaldo Nucleare (Italy) have been tested at the FE200 (AREVA, Le Creusot, France) and ITER Divertor Test Facility (IDTF) (Efremov Institute Saint Petersburg, Russian Federation) electron beam test facilities. The high heat flux (HHF) testing program

  4. High heat flux testing of EU tungsten monoblock mock-ups for the ITER divertor

    Energy Technology Data Exchange (ETDEWEB)

    Gavila, P., E-mail: pierre.gavila@f4e.europa.eu [Fusion for Energy, 08019 Barcelona (Spain); Riccardi, B. [Fusion for Energy, 08019 Barcelona (Spain); Pintsuk, G. [Forschungszentrum Juelich, 52425 Juelich (Germany); Ritz, G. [AREVA NP, Centre Technique France, 71205 Le Creusot (France); Kuznetsov, V. [JCS “Efremov Institute”, Doroga na Metallostroy 3, Metallostroy, Saint-Petersburg 196641 (Russian Federation); Durocher, A. [ITER Organization, Route de Vinon sur Verdon, CS 90 046, 13067 Saint Paul-lez-Durance (France)

    2015-10-15

    Highlights: • All the tested items sustained the ITER Full W divertor qualification program requirements. This confirms that the technology for the manufacturing of the first set of the ITER Divertor is available in Europe. • The surface roughening and local melting of the W surface under high heat flux was proven to be significantly reduced for an armour thickness lower or equal to 6 mm. • However, this campaign highlighted some specific areas of improvement to be implemented ideally before the upcoming ITER Divertor IVT serial production. • The issue of the self-castellation of the W monoblocks, which typically appears after a few tenths of cycles at 20 MW/m{sup 2}, is critical because it generates some uncontrolled defects at the amour to heat sink joints. Besides, they create a gap which exposure is almost perpendicular to the magnetic field lines and which might lead to local W melting in the strike point region. • This campaign also evidenced that the minimum IO requirements on the CuCrZr ductility could be revised to avoid the occurrence of rather early fatigue failures. Although the W material characterization program has been set up by the IO, the strategy on the CuCrZr still needs to be defined. - Abstract: With the aim to assess the option to start the ITER operation with a full tungsten divertor, an R&D program was launched in order to evaluate the performances of tungsten (W) armoured plasma facing components (PFCs) under high heat flux. The F4E program consisted in the manufacturing and high heat flux (HHF) testing of W monoblock mock-ups and medium scale prototypes up to 20 MW/m{sup 2}. During the test campaign, 26 W mock-ups and two medium scale prototypes manufactured by Plansee SE (Austria) and by Ansaldo Nucleare (Italy) have been tested at the FE200 (AREVA, Le Creusot, France) and ITER Divertor Test Facility (IDTF) (Efremov Institute Saint Petersburg, Russian Federation) electron beam test facilities. The high heat flux (HHF) testing

  5. Critical heat flux performance of hypervapotrons proposed for use in the ITER divertor vertical target

    International Nuclear Information System (INIS)

    Youchison, D.L.; Marshall, T.D.; McDonald, J.M.; Lutz, T.J.; Watson, R.D.; Driemeyer, D.E.; Kubik, D.L.; Slattery, K.T.; Hellwig, T.H.

    1997-09-01

    Task T-222 of the International Thermonuclear Experimental Reactor (ITER) program addresses the manufacturing and testing of permanent components for use in the ITER divertor. Thermalhydraulic and critical heat flux performance of the heat sinks proposed for use in the divertor vertical target are part of subtask T-222.4. As part of this effort, two single channel, medium scale, bare copper alloy, hypervapotron mockups were designed, fabricated, and tested using the EB-1200 electron beam system. The objectives of the effort were to develop the design and manufacturing procedures required for construction of robust high heat flux (HHF) components, verify thermalhydraulic, thermomechanical and critical heat flux (CHF) performance under ITER relevant conditions, and perform analyses of HHF data to identify design guidelines and failure criteria and possibly modify any applicable CHF correlations. The design, fabrication, and finite element modeling of two types of hypervapotrons are described; a common version already in use at the Joint European Torus (JET) and a new attached fin design. HHF test data on the attached fin hypervapotron will be used to compare the CHF performance under uniform heating profiles on long heated lengths with that of localized, highly peaked, off nominal profiles

  6. Critical heat flux performance of hypervapotrons proposed for use in the ITER divertor vertical target

    Energy Technology Data Exchange (ETDEWEB)

    Youchison, D.L.; Marshall, T.D.; McDonald, J.M.; Lutz, T.J.; Watson, R.D. [Sandia National Labs., Albuquerque, NM (United States); Driemeyer, D.E. Kubik, D.L.; Slattery, K.T.; Hellwig, T.H. [McDonnell Douglas Aerospace, St. Louis, MO (United States)

    1997-09-01

    Task T-222 of the International Thermonuclear Experimental Reactor (ITER) program addresses the manufacturing and testing of permanent components for use in the ITER divertor. Thermalhydraulic and critical heat flux performance of the heat sinks proposed for use in the divertor vertical target are part of subtask T-222.4. As part of this effort, two single channel, medium scale, bare copper alloy, hypervapotron mockups were designed, fabricated, and tested using the EB-1200 electron beam system. The objectives of the effort were to develop the design and manufacturing procedures required for construction of robust high heat flux (HHF) components, verify thermalhydraulic, thermomechanical and critical heat flux (CHF) performance under ITER relevant conditions, and perform analyses of HHF data to identify design guidelines and failure criteria and possibly modify any applicable CHF correlations. The design, fabrication, and finite element modeling of two types of hypervapotrons are described; a common version already in use at the Joint European Torus (JET) and a new attached fin design. HHF test data on the attached fin hypervapotron will be used to compare the CHF performance under uniform heating profiles on long heated lengths with that of localized, highly peaked, off nominal profiles.

  7. Numerical Study of High Heat Flux Performances of Flat-Tile Divertor Mock-ups with Hypervapotron Cooling Concept

    International Nuclear Information System (INIS)

    Chen Lei; Liu Xiang; Lian Youyun; Cai Laizhong

    2015-01-01

    The hypervapotron (HV), as an enhanced heat transfer technique, will be used for ITER divertor components in the dome region as well as the enhanced heat flux first wall panels. W-Cu brazing technology has been developed at SWIP (Southwestern Institute of Physics), and one W/CuCrZr/316LN component of 450 mm×52 mm×166 mm with HV cooling channels will be fabricated for high heat flux (HHF) tests. Before that a relevant analysis was carried out to optimize the structure of divertor component elements. ANSYS-CFX was used in CFD analysis and ABAQUS was adopted for thermal–mechanical calculations. Commercial code FE-SAFE was adopted to compute the fatigue life of the component. The tile size, thickness of tungsten tiles and the slit width among tungsten tiles were optimized and its HHF performances under International Thermonuclear Experimental Reactor (ITER) loading conditions were simulated. One brand new tokamak HL-2M with advanced divertor configuration is under construction in SWIP, where ITER-like flat-tile divertor components are adopted. This optimized design is expected to supply valuable data for HL-2M tokamak. (paper)

  8. Analyses of divertor high heat-flux components on thermal and electromagnetic loads

    Energy Technology Data Exchange (ETDEWEB)

    Araki, M.; Kitamura, K.; Suzuki, S. [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Urata, K. [Mitsubishi Geavy Industries Ltd., 2-5-1, Marunouchi,Chiyoda-ku, Tokyo 100 (Japan)

    1998-09-01

    In the International Thermonuclear Experimental Reactor (ITER), the divertor high heat-flux components are subjected not to only severe heat and particle loads, but also to large electromagnetic loads during reactor operation. A great deal of R and D has been carried out throughout the world with regard to the design of robust high heat-flux components. Based on R and D results, small and intermediate size mock-ups constructed from various armor tile materials have been successfully developed with respect to a thermomechanical point of view. However, little analysis has been carried out with regard to the elastic stresses induced with in the high heat-flux components via the electromagnetic loads during a plasma disruption. Furthermore, past research has only considered thermomechanical and electromagnetic loadings separately and uncoupled. Therefore, a systematic analysis of the combined effects of thermomechanical and electromagnetic loadings has been performed, with the analytical results assessed by ASME section 3 evaluation code. (orig.) 20 refs.

  9. Analyses of divertor high heat-flux components on thermal and electromagnetic loads

    International Nuclear Information System (INIS)

    Araki, M.; Kitamura, K.; Suzuki, S.

    1998-01-01

    In the International Thermonuclear Experimental Reactor (ITER), the divertor high heat-flux components are subjected not to only severe heat and particle loads, but also to large electromagnetic loads during reactor operation. A great deal of R and D has been carried out throughout the world with regard to the design of robust high heat-flux components. Based on R and D results, small and intermediate size mock-ups constructed from various armor tile materials have been successfully developed with respect to a thermomechanical point of view. However, little analysis has been carried out with regard to the elastic stresses induced with in the high heat-flux components via the electromagnetic loads during a plasma disruption. Furthermore, past research has only considered thermomechanical and electromagnetic loadings separately and uncoupled. Therefore, a systematic analysis of the combined effects of thermomechanical and electromagnetic loadings has been performed, with the analytical results assessed by ASME section 3 evaluation code. (orig.)

  10. Numerical simulation in a subcooled water flow boiling for one-sided high heat flux in reactor divertor

    Energy Technology Data Exchange (ETDEWEB)

    Liu, P., E-mail: pinliu@aust.edu.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China, Hefei 230026 (China); School of Mechanical Engineering, Anhui University of Science and Technology, Huainan 232001 (China); Peng, X.B., E-mail: pengxb@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Song, Y.T. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China, Hefei 230026 (China); Fang, X.D. [Institute of Air Conditioning and Refrigeration, Nanjing University of Aeronautics and Astronautics, Nanjing 210016 (China); Huang, S.H. [University of Science and Technology of China, Hefei 230026 (China); Mao, X. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2016-11-15

    Highlights: • The Eulerian multiphase models coupled with Non-equilibrium Boiling model can effectively simulate the subcooled water flow boiling. • ONB and FDB appear earlier and earlier with the increase of heat fluxes. • The void fraction increases gradually along the flow direction. • The inner CuCrZr tube deteriorates earlier than the outer tungsten layer and the middle OFHC copper layer. - Abstract: In order to remove high heat fluxes for plasma facing components in International Thermonuclear Experimental Reactor (ITER) divertor, a numerical simulation of subcooled water flow boiling heat transfer in a vertically upward smooth tube was conducted in this paper on the condition of one-sided high heat fluxes. The Eulerian multiphase model coupled with Non-equilibrium Boiling model was adopted in numerical simulation of the subcooled boiling two-phase flow. The heat transfer regions, thermodynamic vapor quality (x{sub th}), void fraction and temperatures of three components on the condition of the different heat fluxes were analyzed. Numerical results indicate that the onset of nucleate boiling (ONB) and fully developed boiling (FDB) appear earlier and earlier with increasing heat flux. With the increase of heat fluxes, the inner CuCrZr tube will deteriorate earlier than the outer tungsten layer and the middle oxygen-free high-conductivity (OFHC) copper layer. These results provide a valuable reference for the thermal-hydraulic design of a water-cooled W/Cu divertor.

  11. Numerical Study of High Heat Flux Performances of Flat-Tile Divertor Mock-ups with Hypervapotron Cooling Concept

    Science.gov (United States)

    Chen, Lei; Liu, Xiang; Lian, Youyun; Cai, Laizhong

    2015-09-01

    The hypervapotron (HV), as an enhanced heat transfer technique, will be used for ITER divertor components in the dome region as well as the enhanced heat flux first wall panels. W-Cu brazing technology has been developed at SWIP (Southwestern Institute of Physics), and one W/CuCrZr/316LN component of 450 mm×52 mm×166 mm with HV cooling channels will be fabricated for high heat flux (HHF) tests. Before that a relevant analysis was carried out to optimize the structure of divertor component elements. ANSYS-CFX was used in CFD analysis and ABAQUS was adopted for thermal-mechanical calculations. Commercial code FE-SAFE was adopted to compute the fatigue life of the component. The tile size, thickness of tungsten tiles and the slit width among tungsten tiles were optimized and its HHF performances under International Thermonuclear Experimental Reactor (ITER) loading conditions were simulated. One brand new tokamak HL-2M with advanced divertor configuration is under construction in SWIP, where ITER-like flat-tile divertor components are adopted. This optimized design is expected to supply valuable data for HL-2M tokamak. supported by the National Magnetic Confinement Fusion Science Program of China (Nos. 2011GB110001 and 2011GB110004)

  12. Numerical modeling and validation of helium jet impingement cooling of high heat flux divertor components

    International Nuclear Information System (INIS)

    Koncar, Bostjan; Simonovski, Igor; Norajitra, Prachai

    2009-01-01

    Numerical analyses of jet impingement cooling presented in this paper were performed as a part of helium-cooled divertor studies for post-ITER generation of fusion reactors. The cooling ability of divertor cooled by multiple helium jets was analysed. Thermal-hydraulic characteristics and temperature distributions in the solid structures were predicted for the reference geometry of one cooling finger. To assess numerical errors, different meshes (hexagonal, tetra, tetra-prism) and discretisation schemes were used. The temperatures in the solid structures decrease with finer mesh and higher order discretisation and converge towards finite values. Numerical simulations were validated against high heat flux experiments, performed at Efremov Institute, St. Petersburg. The predicted design parameters show reasonable agreement with measured data. The calculated maximum thimble temperature was below the tile-thimble brazing temperature, indicating good heat removal capability of reference divertor design. (author)

  13. Divertor heat and particle control experiments on the DIII-D tokamak

    International Nuclear Information System (INIS)

    Mahdavi, M.A.; Baker, D.R.; Allen, S.L.

    1994-05-01

    In this paper we present a summary of recent DIII-D divertor physics activity and plans for future divertor upgrades. During the past year, DIII-D experimental effort was focused on areas of active heat and particle control and divertor target erosion studies. Using the DIII-D Advanced Divertor system we have succeeded for the first time to control the plasma density and demonstrate helium exhaust in H-mode plasmas. Divertor heat flux control by means of D 2 gas puffing and impurity injection were studied separately and in, both cases up to a factor of five reduction of the divertor peak heat flux was observed. Using the DiMES sample transfer system we have obtained erosion data on various material samples in well diagnosed plasmas and compared the results with predictions of numerical models

  14. Critical heat flux acoustic detection: Methods and application to ITER divertor vertical target monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, X., E-mail: xavier.courtois@cea.fr [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Escourbiac, F. [ITER Organization, Route de Vinon sur Verdon, F-13115 Saint-Paul-Lez-Durance (France); Richou, M.; Cantone, V. [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Constans, S. [AREVA-NP, Le Creusot (France)

    2013-10-15

    Actively cooled plasma facing components (PFCs) have to exhaust high heat fluxes from plasma radiation and plasma–wall interaction. Critical heat flux (CHF) event may occur in the cooling channel due to unexpected heat loading or operational conditions, and has to be detected as soon as possible. Therefore it is essential to develop means of monitoring based on precursory signals providing an early detection of this destructive phenomenon, in order to be able to stop operation before irremediable damages appear. Capabilities of CHF early detection based on acoustic techniques on PFC mock-ups cooled by pressurised water were already demonstrated. This paper addresses the problem of the detection in case of flow rate reduction and of flow dilution resulting from multiple plasma facing units (PFU) which are hydraulically connected in parallel, which is the case of ITER divertor. An experimental study is launched on a dedicated mock-up submitted to heat loads up to the CHF. It shows that the measurement of the acoustic waves, generated by the cooling phenomena, allows the CHF detection in conditions similar to that of the ITER divertor, with a reasonable number of sensors. The paper describes the mock-ups and the tests sequences, and comments the results.

  15. Examination of high heat flux components for the ITER divertor after thermal fatigue testing

    International Nuclear Information System (INIS)

    Missirlian, M.; Escourbiac, F.; Schmidt, A.; Riccardi, B.; Bobin-Vastra, I.

    2011-01-01

    An extensive development programme has been carried out in the EU on high heat flux components within the ITER project. In this framework, a full-scale vertical target (VTFS) prototype was manufactured with all the main features of the corresponding ITER divertor design. The fatigue cycling campaign on CFC and W armoured regions, proved the capability of such a component to meet the ITER requirements in terms of heat flux performances for the vertical target. This paper discusses metallographic observations performed on both CFC and W part after this intensive thermal fatigue testing campaign for a better understanding of thermally induced mechanical stress within the component, especially close to the armour-heat sink interface.

  16. Examination of high heat flux components for the ITER divertor after thermal fatigue testing

    Energy Technology Data Exchange (ETDEWEB)

    Missirlian, M., E-mail: marc.missirlian@cea.fr [CEA, IRFM, F-13108 Saint Paul lez Durance (France); Escourbiac, F., E-mail: frederic.escourbiac@cea.fr [CEA, IRFM, F-13108 Saint Paul lez Durance (France); Schmidt, A., E-mail: a.schmidt@fz-juelich.de [Forschungszentrum Juelich, IFE-2 (Germany); Riccardi, B., E-mail: Bruno.Riccardi@f4e.europa.eu [Fusion For Energy, E-08019 Barcelona (Spain); Bobin-Vastra, I., E-mail: isabelle.bobinvastra@areva.com [AREVA-NP, 71200 Le Creusot (France)

    2011-10-01

    An extensive development programme has been carried out in the EU on high heat flux components within the ITER project. In this framework, a full-scale vertical target (VTFS) prototype was manufactured with all the main features of the corresponding ITER divertor design. The fatigue cycling campaign on CFC and W armoured regions, proved the capability of such a component to meet the ITER requirements in terms of heat flux performances for the vertical target. This paper discusses metallographic observations performed on both CFC and W part after this intensive thermal fatigue testing campaign for a better understanding of thermally induced mechanical stress within the component, especially close to the armour-heat sink interface.

  17. Progress towards modeling tokamak boundary plasma turbulence and understanding its role in setting divertor heat flux widths

    Science.gov (United States)

    Chen, B.; Xu, X. Q.; Xia, T. Y.; Li, N. M.; Porkolab, M.; Edlund, E.; LaBombard, B.; Terry, J.; Hughes, J. W.; Ye, M. Y.; Wan, Y. X.

    2018-05-01

    The heat flux distributions on divertor targets in H-mode plasmas are serious concerns for future devices. We seek to simulate the tokamak boundary plasma turbulence and heat transport in the edge localized mode-suppressed regimes. The improved BOUT++ model shows that not only Ip but also the radial electric field Er plays an important role on the turbulence behavior and sets the heat flux width. Instead of calculating Er from the pressure gradient term (diamagnetic Er), it is calculated from the plasma transport equations with the sheath potential in the scrape-off layer and the plasma density and temperature profiles inside the separatrix from the experiment. The simulation results with the new Er model have better agreement with the experiment than using the diamagnetic Er model: (1) The electromagnetic turbulence in enhanced Dα H-mode shows the characteristics of quasi-coherent modes (QCMs) and broadband turbulence. The mode spectra are in agreement with the phase contrast imaging data and almost has no change in comparison to the cases which use the diamagnetic Er model; (2) the self-consistent boundary Er is needed for the turbulence simulations to get the consistent heat flux width with the experiment; (3) the frequencies of the QCMs are proportional to Er, while the divertor heat flux widths are inversely proportional to Er; and (4) the BOUT++ turbulence simulations yield a similar heat flux width to the experimental Eich scaling law and the prediction from the Goldston heuristic drift model.

  18. Initial study of divertor particle and heat flux width scaling in lower-single-null configuration on EAST

    International Nuclear Information System (INIS)

    Wang Liang; Xu Guosheng; Guo Houyang; Gan Kaifu; Gong Xianzu; Hu Liqun

    2013-01-01

    The dependence of divertor particle and power deposition widths on plasma current (I_p) for lower hybrid current driven (LHCD) L- and H-mode plasmas was initially studied in the Experimental Advanced Superconducting Tokamak (EAST) under a lower single null (LSN) divertor configuration. And the profile widths were obtained from the divertor triple Langmuir probe array and an infra-red (IR) camera. It is shown that the deposition widths of divertor particle and heat flux profiles both display a strong negative dependence on increasing plasma current, in L-mode, ELM-free H-mode and ELMy H-mode scenarios. The experimental results show good agreement with the heuristic SOL width model proposed by Goldston. (author)

  19. High heat flux test of tungsten brazed mock-ups developed for KSTAR divertor

    Energy Technology Data Exchange (ETDEWEB)

    Song, J.H. [National Fusion Research Institute, Daejeon (Korea, Republic of); Kim, K.M., E-mail: kyungmin@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Hong, S.H.; Kim, H.T.; Park, S.H.; Park, H.K.; Ahn, H.J. [National Fusion Research Institute, Daejeon (Korea, Republic of); Kim, S.K.; Lee, D.W. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-11-01

    The tungsten (W) brazed flat type mock-up which consists of W, OFHC-Cu (oxygen-free high conductive copper) and CuCrZr alloy has been designed for KSTAR divertor in preparation for KSTAR upgrade with 17 MW heating power. For verification of the W brazed mock-up, the high heat flux test is performed at KoHLT-EB (Korea High Heat Load Test Facility-Electron Beam) in KAERI (Korea Atomic Energy Research Institute). Three mock-ups are tested for several thousand thermal cycles with absorbed heat flux up to 5 MW/m{sup 2} for 20 s duration. There is no evidence of the failure at the bonding joints of all mock-ups after HHF test. Finite element analysis (FEA) is performed to interpret the result of the test. As a result, it is considered that the local area in the water is in the subcooled boiling regime.

  20. Effects of the divertor tile geometries and magnetic field angles on the heat fluxes to the surface

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Wanpeng; Sang, Chaofeng; Sun, Zhenyue; Wang, Dezhen, E-mail: wangdez@dlut.edu.cn

    2017-03-15

    Highlights: • Simulation of the plasma behaviors in the divertor gap region is done by using a 2d3 v Particle-In-Cell code. • Heat fluxes on the wall surface in different gap geometries are studied. • The effect of the magnetic field angle on the heat flux is investigated. - Abstract: A two dimension-in-space and three dimension-in-velocity (2d3v) Particle-In-Cell (PIC) code is applied to investigate the plasma behaviors at the divertor gaps region in this work. Electron and D{sup +} ion fluxes to the tile surface in the poloidal and toroidal gaps for different shaped edges are compared to demonstrate the optimized tile geometry. For poloidal gap, shaped edge in the shadowing side makes more ions penetrate into the gap, while shaped edge in the wetted side can mitigate the peak flux value. For toroidal gap, most ions entering the gap impinge on the side tile mainly due to the E × B drift, and shaped wetted edges also can mitigate the peak heat fluxes. In addition, effects of magnetic field inclination angle from toroidal direction on the plasma behaviors are simulated for poloidal and toroidal gaps, respectively. It is found that the magnetic field angles don’t influence the plasma behaviors in poloidal gap; while significant changes have been observed in the toroidal gap.

  1. Fast plasma shutdown by killer pellet injection in JT-60U with reduced heat flux on the divertor plate and avoiding runaway electron generation

    International Nuclear Information System (INIS)

    Yoshino, R.; Kondoh, T.; Neyatani, Y.; Itami, K.; Kawano, Y.; Isei, N.

    1997-01-01

    A killer pellet is an impurity pellet that is injected into a tokamak plasma in order to terminate a discharge without causing serious damage to the tokamak machine. In JT-60U neon ice pellets have been injected into OH and NB heated plasmas and fast plasma shutdowns have been demonstrated without large vertical displacement. The heat pulse on the divertor plate has been greatly reduced by killer pellet injections (KPI), but a low-power heat flux tail with a long time duration is observed. The total energy on the divertor plate increases with longer heat flux tail, so it has been reduced by shortening the tail. Runaway electron (RE) generation has been observed just after KPI and/or in the later phase of the plasma current quench. However, RE generation has been avoided when large magnetic perturbations are excited. These experimental results clearly show that KPI is a credible fast shutdown method avoiding large vertical displacement, reducing heat flux on the divertor plate, and avoiding (or minimizing) RE generation. (Author)

  2. Low energy neutral particle fluxes in the JET divertor

    International Nuclear Information System (INIS)

    Reichle, R.; Horton, L.D.; Ingesson, L.C.; Jaeckel, H.J.; McCormick, G.K.; Loarte, A.; Simonini, R.; Stamp, M.F.

    1997-01-01

    First measurements are presented of the total power loss through neutral particles and their average energy in the JET divertor. The method used distinguishes between the heat flux and the electromagnetic radiation on bolometers. This is done by comparing measurements from inside the divertor either with opposite lines of sight or with a tomographic reconstruction of the radiation. The typical value of the total power loss in the divertor through neutrals is about 1 MW. The average energy of the neutral particles at the inner divertor leg is 1.5-3 eV when detachment is in progress, which agrees with EDGE2D/NIMBUS modelling. (orig.)

  3. Electric probe diagnostics for measuring SOL parameters, wall and divertor fluxes in KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heung-Su, E-mail: kimhs@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Bak, Jun-Gyo [National Fusion Research Institute, Daejeon (Korea, Republic of); Bae, Min-Keun; Chung, Kyu-Sun [Hanyang University, Seoul (Korea, Republic of); Hong, Suk-Ho [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2016-11-01

    Highlights: • Some components in EPDs were improved to investigate characteristics of the SOL plasmas and to measure wall and divertor fluxes in the KSTAR tokamak plasmas. From the upgrades in the EPDs, the measured error of the elapsed distance for the evaluation of the SOL profiles can be reduced up to 1%. • In the SOL parameter measurement during IWL plasma, the e-folding lengths in the main SOL region lTe and lne were evaluated as 3.5 cm and 2.1 cm, respectively. • From flux measurement at the far SOL during a diverted ELMy H-mode, peaked heat flux toward to outboard wall during ELMs might be less than 1% of the peaked divertor heat flux. • The movement of an OSP during a diverted H-mode can be detected from the divertor probe measurement, and the peaked heat flux near the OSP was estimated as few MW m-2. - Abstract: Some components in electric probe diagnostics (EPDs) are improved in order to investigate characteristics of edge plasmas in the upstream scrape-off-layer (SOL) region and to measure wall and divertor fluxes during L-mode and H-mode plasma discharges in the Korea Superconducting Tokamak Advanced Research (KSTAR). From the upgrades in the EPDs, the measured error of the elapsed distance for the evaluation of the SOL profiles can be reduced up to 1% and the ion saturation current of up to 1.0 A near an outer strike point (OSP) can be measured at the divertor region. In the SOL profile measurements during L-mode and inner wall limited plasma (B{sub T} = 2.0 T, I{sub p} = 0.4 MA), the e-folding lengths in the main SOL region λ{sub Te} and λ{sub ne} are evaluated as 3.5 cm and 2.1 cm, respectively. From particle flux measurement at the far SOL region during a diverted ELMy H-mode discharge (B{sub T} = 1.8 T, I{sub p} = 0.65 MA), peaked heat flux toward to outboard wall during ELM bursts is estimated up to ∼20 k Wm{sup −2}, which may be less than 1% of the peaked divertor heat flux expected for the neutral beam (NB) heating power P{sub NB

  4. Results of high heat flux tests of tungsten divertor targets under plasma heat loads expected in ITER and tokamaks (review)

    Energy Technology Data Exchange (ETDEWEB)

    Budaev, V. P., E-mail: budaev@mail.ru [National Research Centre Kurchatov Institute (Russian Federation)

    2016-12-15

    Heat loads on the tungsten divertor targets in the ITER and the tokamak power reactors reach ~10MW m{sup −2} in the steady state of DT discharges, increasing to ~0.6–3.5 GW m{sup −2} under disruptions and ELMs. The results of high heat flux tests (HHFTs) of tungsten under such transient plasma heat loads are reviewed in the paper. The main attention is paid to description of the surface microstructure, recrystallization, and the morphology of the cracks on the target. Effects of melting, cracking of tungsten, drop erosion of the surface, and formation of corrugated and porous layers are observed. Production of submicron-sized tungsten dust and the effects of the inhomogeneous surface of tungsten on the plasma–wall interaction are discussed. In conclusion, the necessity of further HHFTs and investigations of the durability of tungsten under high pulsed plasma loads on the ITER divertor plates, including disruptions and ELMs, is stressed.

  5. Experimental study of heating scheme effect on the inner divertor power footprint widths in EAST lower single null discharges

    Science.gov (United States)

    Deng, G. Z.; Xu, J. C.; Liu, X.; Liu, X. J.; Liu, J. B.; Zhang, H.; Liu, S. C.; Chen, L.; Yan, N.; Feng, W.; Liu, H.; Xia, T. Y.; Zhang, B.; Shao, L. M.; Ming, T. F.; Xu, G. S.; Guo, H. Y.; Xu, X. Q.; Gao, X.; Wang, L.

    2018-04-01

    A comprehensive work of the effects of plasma current and heating schemes on divertor power footprint widths is carried out in the experimental advanced superconducting tokamak (EAST). The divertor power footprint widths, i.e., the scrape-off layer heat flux decay length λ q and the heat spreading S, are crucial physical and engineering parameters for fusion reactors. Strong inverse scaling of λ q and S with plasma current have been demonstrated for both neutral beam (NB) and lower hybrid wave (LHW) heated L-mode and H-mode plasmas at the inner divertor target. For plasmas heated by the combination of the two kinds of auxiliary heating schemes (NB and LHW), the divertor power widths tend to be larger in plasmas with higher ratio of LHW power. Comparison between experimental heat flux profiles at outer mid-plane (OMP) and divertor target for NB heated and LHW heated L-mode plasmas reveals that the magnetic topology changes induced by LHW may be the main reason to the wider divertor power widths in LHW heated discharges. The effect of heating schemes on divertor peak heat flux has also been investigated, and it is found that LHW heated discharges tend to have a lower divertor peak heat flux compared with NB heated discharges under similar input power. All these findings seem to suggest that plasmas with LHW auxiliary heating scheme are better heat exhaust scenarios for fusion reactors and should be the priorities for the design of next-step fusion reactors like China Fusion Engineering Test Reactor.

  6. High heat flux device of thermonuclear device

    International Nuclear Information System (INIS)

    Tachikawa, Nobuo.

    1994-01-01

    The present invention provides an equipments for high heat flux device (divertor) of a thermonuclear device, which absorbs thermal deformation during operation, has a high installation accuracy, and sufficiently withstands for thermal stresses. Namely, a heat sink member is joined to a structural base. Armour tiles are joined on the heat sink member. Cooling pipes are disposed between the heat sink member and the armour tiles. With such a constitution, the heat sink member using a highly heat conductive material having ductility, such as oxygen free copper, the cooling pipes using a material having excellent high temperature resistance and excellent elongation, such as aluminum-dispersed reinforced copper, and the armour tiles are completely joined on the structural base. Therefore, when thermal deformation tends to cause in the high heat flux device such as a divertor, cooling pipes cause no plastic deformation because of their high temperature resistance, but the heat sink member such as a oxygen free copper causes plastic deformation to absorb thermal deformation. As a result, the high heat flux device such as a divertor causes no deformation. (I.S.)

  7. Structures for handling high heat fluxes

    International Nuclear Information System (INIS)

    Watson, R.D.

    1990-01-01

    The divertor is recognized as one of the main performance limiting components for ITER. This paper reviews the critical issues for structures that are designed to withstand heat fluxes >5 MW/m 2 . High velocity, sub-cooled water with twisted tape inserts for enhanced heat transfer provides a critical heat flux limit of 40-60 MW/m 2 . Uncertainties in physics and engineering heat flux peaking factors require that the design heat flux not exceed 10 MW/m 2 to maintain an adequate burnout safety margin. Armor tiles and heat sink materials must have a well matched thermal expansion coefficient to minimize stresses. The divertor lifetime from sputtering erosion is highly uncertain. The number of disruptions specified for ITER must be reduced to achieve a credible design. In-situ plasma spray repair with thick metallic coatings may reduce the problems of erosion. Runaway electrons in ITER have the potential to melt actively cooled components in a single event. A water leak is a serious accident because of steam reactions with hot carbon, beryllium, or tungsten that can mobilize large amounts of tritium and radioactive elements. If the plasma does not shutdown immediately, the divertor can melt in 1-10 s after a loss of coolant accident. Very high reliability of carbon tile braze joints will be required to achieve adequate safety and performance goals. Most of these critical issues will be addressed in the near future by operation of the Tore Supra pump limiters and the JET pumped divertor. An accurate understanding of the power flow out of edge of a DT burning plasma is essential to successful design of high heat flux components. (orig.)

  8. Experimental determination of the transient heat absorption of W divertor materials

    International Nuclear Information System (INIS)

    Greuner, H; Böswirth, B; Eich, T; Herrmann, A; Maier, H; Sieglin, B

    2014-01-01

    Fast infrared (IR) thermography resolves the transient edge localized mode (ELM) induced heat fluxes on divertor components on time scales of a few hundred microseconds. These heat loads range from 10 to several 100 MW m −2 and energy densities of 15–200 kJ m −2 . The calculation of the local ELM heat flux depends on the so-called surface heat transfer coefficient very sensitively. Therefore we performed dedicated experiments in the high heat flux test facility GLADIS with well-defined temporal and spatial shape of heat fluxes to reduce the uncertainties of the ELM heat flux calculations in JET. We have experimentally determined the surface heat transfer coefficient for the W components used as divertor components of the JET ILW project. Based on the results of the measured transient heat absorption, the coefficient was deduced in a temperature range from 400 to 1200 °C for the bulk W lamella and for 10 and 20 μm W-coated carbon fibre reinforced carbon tiles, respectively. The measurements allow an improved estimation of ELM heat loads in JET on W and W-coated tiles and an error estimate of the absorbed heat flux. (paper)

  9. Results and analysis of high heat flux tests on a full-scale vertical target prototype of ITER divertor

    International Nuclear Information System (INIS)

    Missirlian, M.; Escourbiac, F.; Merola, M.; Bobin-Vastra, I.; Schlosser, J.; Durocher, A.

    2005-01-01

    After an extensive R and D development program, a full-scale divertor target prototype, manufactured with all the main features of the corresponding ITER divertor, was intensively tested in the high heat flux FE200 facility. The prototype consists of four units having a full monoblock geometry. The lower part (CFC armour) and the upper part (W armour) of each monoblock were joined to the solution annealed, quenched and cold worked CuCrZr tube by HIP technique. This paper summarises and analyses the main test results obtained on this prototype

  10. Scrape-off layer radiation and heat load to the ASDEX Upgrade LYRA divertor

    International Nuclear Information System (INIS)

    Kallenbach, A.; Kaufmann, M.; Coster, D.P.

    1999-01-01

    In 1997 the new 'LYRA' divertor went into operation at ASDEX Upgrade and, in parallel, the neutral beam heating power was increased to 20 MW by installation of a second injector leading to a P/R value of 12 MW/m. Experiments have shown that the ASDEX Upgrade LYRA divertor is capable of handling such high heating powers. There is an overall reduction of the maximum heat flux in the LYRA divertor by about a factor of 2 compared with the previous open divertor Div I. This reduction is mainly due to increased radiative losses inside the divertor region, which are caused by an effective reflection of hydrogen neutrals into the hot separatrix region. The main channel of radiative loss is carbon radiation, which cools the divertor plasma down to a few electronvolts, where hydrogen radiation losses become significant. The radiative losses preferentially reduce the power flux at the separatrix, leading to early detachment around the strike point position. With increasing density, the detached region extends upwards on the vertical target. The power fraction radiated in the LYRA divertor is around 45% and nearly independent of the heating power. This value is a factor of 2 higher than the typical radiation fraction in Div I. B2-EIRENE modelling of the performed experiments supports the experimental finding and refines the understanding of loss processes in the divertor region. (author)

  11. High heat flux facility GLADIS

    International Nuclear Information System (INIS)

    Greuner, H.; Boeswirth, B.; Boscary, J.; McNeely, P.

    2007-01-01

    The new ion beam facility GLADIS started the operation at IPP Garching. The facility is equipped with two individual 1.1 MW power ion sources for testing actively cooled plasma facing components under high heat fluxes. Each ion source generates heat loads between 3 and 55 MW/m 2 with a beam diameter of 70 mm at the target position. These parameters allow effective testing from probes to large components up to 2 m length. The high heat flux allows the target to be installed inclined to the beam and thus increases the heated surface length up to 200 mm for a heat flux of 15 MW/m 2 in the standard operating regime. Thus the facility has the potential capability for testing of full scale ITER divertor targets. Heat load tests on the WENDELSTEIN 7-X pre-series divertor targets have been successfully started. These tests will validate the design and manufacturing for the production of 950 elements

  12. Application of the radiating divertor approach to innovative tokamak divertor concepts

    Energy Technology Data Exchange (ETDEWEB)

    Petrie, T.W., E-mail: petrie@fusion.gat.com [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Allen, S.L.; Fenstermacher, M.E. [Lawrence Livermore National Laboratory, 700 East Ave, Livermore, CA 94550 (United States); Groebner, R.J. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Holcomb, C.T. [Lawrence Livermore National Laboratory, 700 East Ave, Livermore, CA 94550 (United States); Kolemen, E. [Princeton Plasma Physics Laboratory, PO Box 451, Princeton, NJ 08543-0451 (United States); La Haye, R.J. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Lasnier, C.J. [Lawrence Livermore National Laboratory, 700 East Ave, Livermore, CA 94550 (United States); Leonard, A.W.; Luce, T.C. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); McLean, A.G. [Lawrence Livermore National Laboratory, 700 East Ave, Livermore, CA 94550 (United States); Maingi, R. [Princeton Plasma Physics Laboratory, PO Box 451, Princeton, NJ 08543-0451 (United States); Moyer, R.A. [University of California San Diego, 9500 Gilman Dr., La Jolla, CA 92093-0417 (United States); Solomon, W.M. [Princeton Plasma Physics Laboratory, PO Box 451, Princeton, NJ 08543-0451 (United States); Soukhanovskii, V.A. [Lawrence Livermore National Laboratory, 700 East Ave, Livermore, CA 94550 (United States); Turco, F. [Columbia University, 2960 Broadway, New York, NY 10027 (United States); Watkins, J.G. [Sandia National Laboratory, PO Box 5800, Albuquerque, NM 87185 (United States)

    2015-08-15

    We survey the results of recent DIII-D experiments that tested the effectiveness of three innovative tokamak divertor concepts in reducing divertor heat flux while still maintaining acceptable energy confinement under neon/deuterium-based radiating divertor (RD) conditions: (1) magnetically unbalanced high performance double-null divertor (DND) plasmas, (2) high performance double-null “Snowflake” (SF-DN) plasmas, and (3) single-null H-mode plasmas having different isolation from their divertor targets. In general, all three concepts adapt well to RD conditions, achieving significant reduction in divertor heat flux (q{sub ⊥p}) and maintaining high performance metrics, e.g., 50–70% reduction in peak divertor heat flux for DND and SF-DN plasmas that are characterized by β{sub N} ≅ 3.0 and H{sub 98(y,2)} ≈ 1.35. It is also demonstrated that q{sub ⊥p} could be reduced ≈50% by extending the parallel connection length (L{sub ||-XPT}) in the scrape-off layer between the X-point and divertor targets over a variety of the RD and non-RD environments tested.

  13. Thermal response to heat fluxes of the W7-AS divertor surface submitted to surface modification under high temperature treatment

    Energy Technology Data Exchange (ETDEWEB)

    Hildebrandt, D., E-mail: dieter.hildebrandt@ipp.mpg.d [Euratom Association, Max-Planck-Institut fuer Plasmaphysik, Teilinstitut Greifswald, Wendelsteinstrasse 1, 17491 Greifswald (Germany); Duebner, A. [Euratom Association, Max-Planck-Institut fuer Plasmaphysik, Teilinstitut Greifswald, Wendelsteinstrasse 1, 17491 Greifswald (Germany); Greuner, H.; Wiltner, A. [Teilinstitut Garching, Boltzmannstr. 2, 85748 Garching (Germany)

    2009-06-15

    Some target tiles of the W7-AS divertor has been investigated with respect to their thermal behaviour at the surface during power loading with well-defined heat fluxes in the Gladis facility. The primary aim was to examine uncertainties in the determination of heat fluxes derived from IR-thermography during operation of W7-AS. It is found that the derived heat flux profiles are strongly influenced by the local distribution of plasma-deposited contamination analyzed by AES and SIMS. With the observed actual surface conditions characterized by redeposited contamination equivalent up to about 1 mum thickness, the heat fluxes were partially overestimated up to a factor of 4 during operation of W7-AS. This uncertainty is observed to be significantly reduced after heat treatment at temperatures beyond 700 deg. C attained at power flux densities of 10.5 MW/m{sup 2} and durations longer than 5 s.

  14. Thermal response to heat fluxes of the W7-AS divertor surface submitted to surface modification under high temperature treatment

    International Nuclear Information System (INIS)

    Hildebrandt, D.; Duebner, A.; Greuner, H.; Wiltner, A.

    2009-01-01

    Some target tiles of the W7-AS divertor has been investigated with respect to their thermal behaviour at the surface during power loading with well-defined heat fluxes in the Gladis facility. The primary aim was to examine uncertainties in the determination of heat fluxes derived from IR-thermography during operation of W7-AS. It is found that the derived heat flux profiles are strongly influenced by the local distribution of plasma-deposited contamination analyzed by AES and SIMS. With the observed actual surface conditions characterized by redeposited contamination equivalent up to about 1 μm thickness, the heat fluxes were partially overestimated up to a factor of 4 during operation of W7-AS. This uncertainty is observed to be significantly reduced after heat treatment at temperatures beyond 700 deg. C attained at power flux densities of 10.5 MW/m 2 and durations longer than 5 s.

  15. Testing of high heat flux components manufactured by ENEA for ITER divertor

    International Nuclear Information System (INIS)

    Visca, Eliseo; Escourbiac, F.; Libera, S.; Mancini, A.; Mazzone, G.; Merola, M.; Pizzuto, A.

    2009-01-01

    ENEA is involved in the International Thermonuclear Experimental Reactor (ITER) R and D activities and in particular in the manufacturing of high heat flux plasma-facing components, such as the divertor targets. During the last years ENEA has manufactured actively cooled mock-ups by using different technologies, namely brazing, diffusion bonding and HIPping. A new manufacturing process that combines two main techniques PBC (Pre-Brazed Casting) and the HRP (Hot Radial Pressing) has been set up and widely tested. A full monoblock medium scale vertical target, having a straight CFC armoured part and a curved W armoured part, was manufactured using this process. The ultrasonic method was used for the non-destructive examinations performed during the manufacturing of the component, from the monoblock preparation up to the final mock-up assembling. The component was also examined by thermography on SATIR facility (CEA, France), afterwards it was thermal fatigue tested at FE200 (200 kW electron beam facility, CEA/AREVA France). The successful results of the thermal fatigue testing performed according the ITER requirements (10 MW/m 2 , 3000 cycles of 10 s on both CFC and W part, then 20/15 MW/m 2 , 2000 cycles of 10 s on CFC/W part, respectively) have confirmed that the developed process can be considerate a candidate for the manufacturing of monoblock divertor components. Furthermore, a 35-MW/m 2 Critical Heat Flux was measured at relevant thermal-hydraulics conditions at the end of the testing campaign. This paper reports the manufacturing route, the thermal fatigue testing results, the pre and post non-destructive examination and the destructive examination performed on the ITER vertical target medium scale mock-up. These activities were performed in the frame of EFDA contracts (04-1218 with CEA, 93-851 JN with AREVA and 03-1054 with ENEA).

  16. High-heat-flux testing of helium-cooled heat exchangers for fusion applications

    International Nuclear Information System (INIS)

    Youchison, D.L.; Izenson, M.G.; Baxi, C.B.; Rosenfeld, J.H.

    1996-01-01

    High-heat-flux experiments on three types of helium-cooled divertor mock-ups were performed on the 30-kW electron beam test system and its associated helium flow loop at Sandia National Laboratories. A dispersion-strengthened copper alloy (DSCu) was used in the manufacture of all the mock-ups. The first heat exchanger provides for enhanced heat transfer at relatively low flow rates and much reduced pumping requirements. The Creare sample was tested to a maximum absorbed heat flux of 5.8 MW/m 2 . The second used low pressure drops and high mass flow rates to achieve good heat removal. The GA specimen was tested to a maximum absorbed heat flux of 9 MW/m 2 while maintaining a surface temperature below 400 degree C. A second experiment resulted in a maximum absorbed heat flux of 34 MW/m 2 and surface temperatures near 533 degree C. The third specimen was a DSCu, axial flow, helium-cooled divertor mock-up filled with a porous metal wick which effectively increases the available heat transfer area. Low mass flow and high pressure drop operation at 4.0 MPa were characteristic of this divertor module. It survived a maximum absorbed heat flux of 16 MW/m 2 and reached a surface temperature of 740 degree C. Thermacore also manufactured a follow-on, dual channel porous metal-type heat exchanger, which survived a maximum absorbed heat flux of 14 MW/m 2 and reached a maximum surface temperature of 690 degree C. 11refs., 20 figs., 3 tabs

  17. Progress towards modeling tokamak boundary plasma turbulence and understanding its role in setting divertor heat flux widths

    Science.gov (United States)

    Chen, Bin

    2017-10-01

    QCMs (quasi-coherent modes) are well characterized in the edge of Alcator C-Mod, when operating in the Enhanced Dα (EDA) H-mode, a promising alternative regime for ELM (edge localized modes) suppressed operation. To improve the understanding of the physics behind the QCMs, three typical C-Mod EDA H-Mode discharges are simulated by BOUT + + using a six-field two-fluid model (based on the Braginskii equations). The simulated characteristics of the frequency versus wave number spectra of the modes is in reasonable agreement with phase contrast imaging data. The key simulation results are: 1) Linear spectrum analysis and the nonlinear phase relationship indicate the dominance of resistive-ballooning modes and drift-Alfven wave instabilities; 2) QCMs originate inside the separatrix; (3) magnetic flutter causes the mode spreading into the SOL; 4) the boundary electric field Er changes the turbulent characteristics of the QCMs and controls edge transport and the divertor heat flux width; 5) the magnitude of the divertor heat flux depends on the physics models, such as sources and sinks, sheath boundary conditions, and parallel heat flux limiting coefficient. The BOUT + + simulations have also been performed for inter-ELM periods of DIII-D and EAST discharges, and similar quasi-coherent modes have been found. The parallel electron heat fluxes projected onto the target from these BOUT + + simulations follow the experimental heat flux width scaling, in particular the inverse dependence of the width on the poloidal magnetic field with an outlier. Further turbulence statistics analysis shows that the blobs are generated near the pedestal peak gradient region inside the separatrix and contribute to the transport of the particle and heat in the SOL region. To understand the Goldston heuristic drift-based model, results will also be presented from self-consistent transport simulations with the electric and magnetic drifts in BOUT + + and with the sheath potential included in the

  18. Mitigation of divertor heat flux by high-frequency ELM pacing with non-fuel pellet injection in DIII-D

    Directory of Open Access Journals (Sweden)

    A. Bortolon

    2017-08-01

    Full Text Available Experiments have been conducted on DIII-D investigating high repetition rate injection of non-fuel pellets as a tool for pacing Edge Localized Modes (ELMs and mitigating their transient divertor heat loads. Effective ELM pacing was obtained with injection of Li granules in different H-mode scenarios, at frequencies 3–5 times larger than the natural ELM frequency, with subsequent reduction of strike-point heat flux (Bortolon et al., Nucl. Fus., 56, 056008, 2016. However, in scenarios with high pedestal density (∼6 ×1019m−3, the magnitude of granule triggered ELMs shows a broad distribution, in terms of stored energy loss and peak heat flux, challenging the effectiveness of ELM mitigation. Furthermore, transient heat-flux deposition correlated with granule injections was observed far from the strike-points. Field line tracing suggest this phenomenon to be consistent with particle loss into the mid-plane far scrape-off layer, at toroidal location of the granule injection.

  19. Effect of stationary high heat flux and transient ELMs-like heat loads on the divertor PFCs

    Energy Technology Data Exchange (ETDEWEB)

    Riccardi, B., E-mail: bruno.riccardi@f4e.europa.eu [Fusion for Energy, ITER Department, Josep Pla, 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Gavila, P. [Fusion for Energy, ITER Department, Josep Pla, 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Giniatulin, R. [Efremov Institute, 196641 St. Petersburg (Russian Federation); Kuznetsov, V. [SRC RF TRINITI, ul. Pushkovykh, vladenie 12, 142190 Troitsk, Moscow Region (Russian Federation); Rulev, R. [Efremov Institute, 196641 St. Petersburg (Russian Federation); Klimov, N.; Kovalenko, D.; Barsuk, V. [SRC RF TRINITI, ul. Pushkovykh, vladenie 12, 142190 Troitsk, Moscow Region (Russian Federation); Koidan, V.; Korshunov, S. [NRC “Kurchatov Institute”, Moscow (Russian Federation)

    2013-10-15

    The experimental evaluation of the divertor plasma facing components (PFCs) lifetime under transient events, such as edge localized modes (ELMs) and high heat flux (HHF) thermal fatigue expected during ITER normal operations and slow transient events is here presented. The experiments have been performed in the frame of an EU/RF collaboration. For carbon fiber composite material the erosion is caused by PAN fiber damage whilst the erosion of tungsten is determined by the melt layer movement and crack formation. The conclusion of this study is that, in addition to the structural change produced in the armor materials by ELMs-like loads, some mock ups showed also a degradation of the thermal fatigue performances.

  20. Feasibility study of fast swept divertor strike point suppressing transient heat fluxes in big tokamaks.

    Czech Academy of Sciences Publication Activity Database

    Horáček, Jan; Cunningham, G.; Entler, Slavomír; Dobias, P.; Duban, R.; Imríšek, Martin; Markovič, Tomáš; Havlíček, Josef; Enikeev, R.

    2017-01-01

    Roč. 123, November (2017), s. 646-649 ISSN 0920-3796. [SOFT 2016: Symposium on Fusion Technology /29./. Prague, 05.09.2016-09.09.2016] R&D Projects: GA ČR(CZ) GA16-14228S; GA MŠk(CZ) LM2015045; GA MŠk(CZ) 8D15001; GA MŠk LG14002 Institutional support: RVO:61389021 Keywords : DEMO * ELM * Divertor * Heat flux * Tokamak Subject RIV: JF - Nuclear Energetics OBOR OECD: Nuclear related engineering Impact factor: 1.319, year: 2016 http://www.sciencedirect.com/science/article/pii/S0920379617300376

  1. Divertor detachment

    Science.gov (United States)

    Krasheninnikov, Sergei

    2015-11-01

    The heat exhaust is one of the main conceptual issues of magnetic fusion reactor. In a standard operational regime the large heat flux onto divertor target reaches unacceptable level in any foreseeable reactor design. However, about two decades ago so-called ``detached divertor'' regimes were found. They are characterized by reduced power and plasma flux on divertor targets and look as a promising solution for heat exhaust in future reactors. In particular, it is envisioned that ITER will operate in a partly detached divertor regime. However, even though divertor detachment was studied extensively for two decades, still there are some issues requiring a new look. Among them is the compatibility of detached divertor regime with a good core confinement. For example, ELMy H-mode exhibits a very good core confinement, but large ELMs can ``burn through'' detached divertor and release large amounts of energy on the targets. In addition, detached divertor regimes can be subject to thermal instabilities resulting in the MARFE formation, which, potentially, can cause disruption of the discharge. Finally, often inner and outer divertors detach at different plasma conditions, which can lead to core confinement degradation. Here we discuss basic physics of divertor detachment including different mechanisms of power and momentum loss (ionization, impurity and hydrogen radiation loss, ion-neutral collisions, recombination, and their synergistic effects) and evaluate the roles of different plasma processes in the reduction of the plasma flux; detachment stability; and an impact of ELMs on detachment. We also evaluate an impact of different magnetic and divertor geometries on detachment onset, stability, in- out- asymmetry, and tolerance to the ELMs. Supported by the U.S. Department of Energy Office of Science, Office of Fusion Energy Sciences under Award Number DE-DE-FG02-04ER54739 at UCSD.

  2. Snowflake divertor configuration studies in National Spherical Torus Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Soukhanovskii, V. A.; McLean, A. G.; Rognlien, T. D.; Ryutov, D. D.; Umansky, M. V. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Bell, R. E.; Diallo, A.; Gerhardt, S.; Kaye, S.; Kolemen, E.; LeBlanc, B. P.; Menard, J. E.; Paul, S. F.; Podesta, M.; Roquemore, A. L.; Scotti, F.; Battaglia, D.; Bell, M. G.; Gates, D. A.; Kaita, R. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); and others

    2012-08-15

    Experimental results from NSTX indicate that the snowflake divertor (D. Ryutov, Phys. Plasmas 14, 064502 (2007)) may be a viable solution for outstanding tokamak plasma-material interface issues. Steady-state handling of divertor heat flux and divertor plate erosion remains to be critical issues for ITER and future concept devices based on conventional and spherical tokamak geometry with high power density divertors. Experiments conducted in 4-6 MW NBI-heated H-mode plasmas in NSTX demonstrated that the snowflake divertor is compatible with high-confinement core plasma operation, while being very effective in steady-state divertor heat flux mitigation and impurity reduction. A steady-state snowflake divertor was obtained in recent NSTX experiments for up to 600 ms using three divertor magnetic coils. The high magnetic flux expansion region of the scrape-off layer (SOL) spanning up to 50% of the SOL width {lambda}{sub q} was partially detached in the snowflake divertor. In the detached zone, the heat flux profile flattened and decreased to 0.5-1 MW/m{sup 2} (from 4-7 MW/m{sup 2} in the standard divertor) indicative of radiative heating. An up to 50% increase in divertor, P{sub rad} in the snowflake divertor was accompanied by broadening of the intrinsic C III and C IV radiation zones, and a nearly order of magnitude increase in divertor high-n Balmer line emission indicative of volumetric recombination onset. Magnetic reconstructions showed that the x-point connection length, divertor plasma-wetted area and divertor volume, all critical parameters for geometric reduction of deposited heat flux, and increased volumetric divertor losses were significantly increased in the snowflake divertor, as expected from theory.

  3. 2-D temperature distribution and heat flux of PFC in 2011 KSTAR campaign

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Eunnam, E-mail: bang14@nfri.re.kr; Hong, Suk-Ho; Yu, Yaowei; Kim, Kyungmin; Kim, Hongtack; Kim, Hakkun; Lee, Kunsu; Yang, Hyunglyul

    2013-10-15

    Highlights: • The heat flux on PFC tiles of 12 s pulse duration and 630 kA plasma current is about 0.02 MW/m{sup 2}. • When the cryopump is operated, the heat flux of CD is higher than without cryopump. • The more H-mode duration is long, the more heat flux on divertor is high. -- Abstract: KSTAR has reached a plasma current up to 630 kA, plasma duration up to 12 s, and has achieved high confinement mode (H-mode) in 2011 campaign. The heat flux of PFC tile was estimated from the temperature increase of PFC since 2010. The heat flux of PFC tiles increases significantly with higher plasma current and longer pulse duration. The time-averaged heat flux of shots in 2010 campaign (with 3 s pulse durations and I{sub p} of 611 kA) is 0.01 MW/m{sup 2} while that in 2011 campaign (with 12 s pulse duration and I{sub p} of 630 kA) is about 0.02 MW/m{sup 2}. The heat flux at divertor is 1.4–2 times higher than that at inboard limiter or passive stabilizer. With the cryopump operation, the heat flux at the central divertor is higher than that without cryopump. The heat flux at divertor is proportional to, of course, the duration of H-mode. Furthermore, a software tool, which visualizes the 2D temperature distribution of PFC tile and estimates the heat flux in real time, is developed.

  4. Snowflake Divertor Configuration in NSTX

    International Nuclear Information System (INIS)

    Soukhanovskii, V.A.; Ahn, Joonwook; Bell, R.E.; Gates, D.A.; Gerhardt, S.; Kaita, R.; Kolemen, E.; Kugel, H.W.; LeBlanc, B.; Maingi, Rajesh; Maqueda, R.J.; McLean, Adam G.; Menard, J.E.; Mueller, D.; Paul, S.F.; Raman, R.; Roquemore, L.; Ryutov, D.D.; Scott, H.A.

    2011-01-01

    Steady-state handling of divertor heat flux is a critical issue for present and future conventional and spherical tokamaks with compact high power density divertors. A novel 'snowflake' divertor (SFD) configuration that takes advantage of magnetic properties of a second-order poloidal null has been predicted to have a larger plasma-wetted area and a larger divertor volume, in comparison with a standard first-order poloidal X-point divertor configuration. The SFD was obtained in 0.8 MA, 4-6 MW NBI-heated H-mode discharges in NSTX using two divertor magnetic coils. The SFD led to a partial detachment of the outer strike point even in low-collisionality scrape-off layer plasma obtained with lithium coatings in NSTX. Significant divertor peak heat flux reduction and impurity screening have been achieved simultaneously with good core confinement and MHD properties.

  5. 'Snowflake' divertor configuration in NSTX

    International Nuclear Information System (INIS)

    Soukhanovskii, V.A.; Ahn, J.-W.; Bell, R.E.; Gates, D.A.; Gerhardt, S.; Kaita, R.; Kolemen, E.; Kugel, H.W.; LeBlanc, B.P.; Maingi, R.; Maqueda, R.; McLean, A.; Menard, J.E.; Mueller, D.M.; Paul, S.F.; Raman, R.; Roquemore, A.L.; Ryutov, D.D.; Scott, H.A.

    2011-01-01

    Steady-state handling of divertor heat flux is a critical issue for present and future conventional and spherical tokamaks with compact high power density divertors. A novel 'snowflake' divertor (SFD) configuration that takes advantage of magnetic properties of a second-order poloidal null has been predicted to have a larger plasma-wetted area and a larger divertor volume, in comparison with a standard first-order poloidal X-point divertor configuration. The SFD was obtained in 0.8 MA, 4-6 MW NBI-heated H-mode discharges in NSTX using two divertor magnetic coils. The SFD led to a partial detachment of the outer strike point even in low-collisionality scrape-off layer plasma obtained with lithium coatings in NSTX. Significant divertor peak heat flux reduction and impurity screening have been achieved simultaneously with good core confinement and MHD properties.

  6. "Snowflake" divertor configuration in NSTX

    Science.gov (United States)

    Soukhanovskii, V. A.; Ahn, J.-W.; Bell, R. E.; Gates, D. A.; Gerhardt, S.; Kaita, R.; Kolemen, E.; Kugel, H. W.; Leblanc, B. P.; Maingi, R.; Maqueda, R.; McLean, A.; Menard, J. E.; Mueller, D. M.; Paul, S. F.; Raman, R.; Roquemore, A. L.; Ryutov, D. D.; Scott, H. A.

    2011-08-01

    Steady-state handling of divertor heat flux is a critical issue for present and future conventional and spherical tokamaks with compact high power density divertors. A novel "snowflake" divertor (SFD) configuration that takes advantage of magnetic properties of a second-order poloidal null has been predicted to have a larger plasma-wetted area and a larger divertor volume, in comparison with a standard first-order poloidal X-point divertor configuration. The SFD was obtained in 0.8 MA, 4-6 MW NBI-heated H-mode discharges in NSTX using two divertor magnetic coils. The SFD led to a partial detachment of the outer strike point even in low-collisionality scrape-off layer plasma obtained with lithium coatings in NSTX. Significant divertor peak heat flux reduction and impurity screening have been achieved simultaneously with good core confinement and MHD properties.

  7. Snowflake divertor configuration studies for NSTX-Upgrade

    International Nuclear Information System (INIS)

    Soukhanovskii, V.A.

    2011-01-01

    Snowflake divertor experiments in NSTX provide basis for PMI development toward NSTX-Upgrade. Snowflake configuration formation was followed by radiative detachment. Significant reduction of steady-state divertor heat flux observed in snowflake divertor. Impulsive heat loads due to Type I ELMs are partially mitigated in snowflake divertor. Magnetic control of snowflake divertor configuration is being developed. Plasma material interface development is critical for NSTX-U success. Four divertor coils should enable flexibility in boundary shaping and control in NSTX-U. Snowflake divertor experiments in NSTX provide good basis for PMI development in NSTX-Upgrade. FY 2009-2010 snowflake divertor experiments in NSTX: (1) Helped understand control of magnetic properties; (2) Core H-mode confinement unchanged; (3) Core and edge carbon concentration reduced; and (4) Divertor heat flux significantly reduced - (a) Steady-state reduction due to geometry and radiative detachment, (b) Encouraging results for transient heat flux handling, (c) Combined with impurity-seeded radiative divertor. Outlook for snowflake divertor in NSTX-Upgrade: (1) 2D fluid modeling of snowflake divertor properties scaling - (a) Edge and divertor transport, radiation, detachment threshold, (b) Compatibility with cryo-pump and lithium conditioning; (2) Magnetic control development; and (3) PFC development - PFC alignment and PFC material choice.

  8. Thermographic studies of outer target heat fluxes on KSTAR

    Directory of Open Access Journals (Sweden)

    H.H. Lee

    2017-08-01

    Full Text Available A new infra-red (IR thermography system with high spatial resolution has been installed on KSTAR and is now mainly applied to measure the outer divertor heat load profile. The first measurement results of the outer divertor heat load profiles between ELMs have been applied to characterize the inter-ELMs outer divertor heat loads in KSTAR H-mode plasmas. In particular, the power decay length (λq of the divertor heat load profile has been determined by fitting the profile to a convolution of an exponential decay and a Gaussian function. The analysis on the power decay length shows a good agreement with the recent multi-machine λq scaling, which predicts λq of the inter-ELMs divertor heat load to be ∼1 mm under the standard H-mode scenario in ITER. The divertor IR thermography system has also successfully measured the strike point splitting of the outer divertor heat flux during the application of resonant magnetic perturbation (RMP fields. In addition, it has provided a clear evidence that the strike point splitting pattern depends on the RMP fields configuration.

  9. Results and analysis of high heat flux tests on a full scale vertical target prototype of ITER divertor

    International Nuclear Information System (INIS)

    Missirlian, M.; Escourbiac, F.; Schlosser, J.; Durocher, A.; Bobin-Vastra, I.

    2004-01-01

    After an extensive development program, a Full-Scale Divertor Target prototype (VTFS) manufactured with all the main features of the corresponding ITER divertor, was intensively tested in the high heat flux FE200 facility. The prototype consists of four units having a full mono-block geometry. The lower part (CFC armour) and the upper part (W armour) of each mono-block were joined to the solution annealed, quenched and cold worked CuCrZr tube by HIP technique. The CFC mono-block was successfully tested up to 1000 cycles at 23 MW/m 2 without any indication of failure. This value is well beyond the ITER design target of 300 cycles at 20 MW/m 2 . The W mono-block endured ∼600 cycles at 10 MW/m 2 . This value of flux is one order of magnitude higher than the ITER design target for the upper part of the vertical target. Fatigue damage is observed when pursuing the cycling up to 15 MW/m 2 . A first stress analysis seems to predict these factual results. However, macro-graphic examinations should bring a better damage valuation. Meanwhile, the fatigue testing will continue on the W healthy part of the VTFS prototype with castellation located on the heated surface (reducing the stresses close to the W-Cu interface). (authors)

  10. Results and analysis of high heat flux tests on a full scale vertical target prototype of ITER divertor

    Energy Technology Data Exchange (ETDEWEB)

    Missirlian, M.; Escourbiac, F.; Schlosser, J.; Durocher, A. [Association Euratom-CEA, Centre d' Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Merola, M. [EFDA Close Support Unit, Garching (Germany); Bobin-Vastra, I. [Framatome, 71 - Le Creusot (France)

    2004-07-01

    After an extensive development program, a Full-Scale Divertor Target prototype (VTFS) manufactured with all the main features of the corresponding ITER divertor, was intensively tested in the high heat flux FE200 facility. The prototype consists of four units having a full mono-block geometry. The lower part (CFC armour) and the upper part (W armour) of each mono-block were joined to the solution annealed, quenched and cold worked CuCrZr tube by HIP technique. The CFC mono-block was successfully tested up to 1000 cycles at 23 MW/m{sup 2} without any indication of failure. This value is well beyond the ITER design target of 300 cycles at 20 MW/m{sup 2}. The W mono-block endured {approx}600 cycles at 10 MW/m{sup 2}. This value of flux is one order of magnitude higher than the ITER design target for the upper part of the vertical target. Fatigue damage is observed when pursuing the cycling up to 15 MW/m{sup 2}. A first stress analysis seems to predict these factual results. However, macro-graphic examinations should bring a better damage valuation. Meanwhile, the fatigue testing will continue on the W healthy part of the VTFS prototype with castellation located on the heated surface (reducing the stresses close to the W-Cu interface). (authors)

  11. Copper matrix composites as heat sink materials for water-cooled divertor target

    Directory of Open Access Journals (Sweden)

    Jeong-Ha You

    2015-12-01

    Full Text Available According to the recent high heat flux (HHF qualification tests of ITER divertor target mock-ups and the preliminary design studies of DEMO divertor target, the performance of CuCrZr alloy, the baseline heat sink material for DEMO divertor, seems to only marginally cover the envisaged operation regime. The structural integrity of the CuCrZr heat sink was shown to be affected by plastic fatigue at 20 MW/m². The relatively high neutron irradiation dose expected for the DEMO divertor target is another serious concern, as it would cause significant embrittlement below 250 °C or irradiation creep above 350 °C. Hence, an advanced design concept of the divertor target needs to be devised for DEMO in order to enhance the HHF performance so that the structural design criteria are fulfilled for full operation scenarios including slow transients. The biggest potential lies in copper-matrix composite materials for the heat sink. In this article, three promising Cu-matrix composite materials are reviewed in terms of thermal, mechanical and HHF performance as structural heat sink materials. The considered candidates are W particle-reinforced, W wire-reinforced and SiC fiber-reinforced Cu matrix composites. The comprehensive results of recent studies on fabrication technology, design concepts, materials properties and the HHF performance of mock-ups are presented. Limitations and challenges are discussed.

  12. Model of divertor biasing and control of scrape-off layer and divertor plasmas

    International Nuclear Information System (INIS)

    Nagasaki, K.; Itoh, K.; Itoh, S.

    1991-02-01

    Analytic model of the divertor biasing is described. For the given plasma and energy sources from the core plasma, the heat and particle flux densities on the divertor plate as well as scrape-off-layer (SOL)/divertor plasmas are analyzed in a slab model. Using a two-dimensional model, the effects of the divertor biasing and SOL current are studied. The conditions to balance the plasma temperature or sheath potential on different divertor plates are obtained. Effect of the SOL current on the heat channel width is also discussed. (author)

  13. Divertor scenario development for NSTX Upgrade

    Science.gov (United States)

    Soukhanovskii, V. A.; McLean, A. G.; Meier, E. T.; Rognlien, T. D.; Ryutov, D. D.; Bell, R. E.; Diallo, A.; Gerhardt, S. P.; Kaita, R.; Kolemen, E.; Leblanc, B. P.; Menard, J. E.; Podesta, M.; Scotti, F.

    2012-10-01

    In the NSTX-U tokamak, initial plans for divertor plasma-facing components (PFCs) include lithium and boron coated graphite, with a staged transition to molybdenum. Steady-state peak divertor heat fluxes are projected to reach 20-30 MW/m^2 in 2 MA, 12 MW NBI-heated discharges of up to 5 s duration, thus challenging PFC thermal limits. Based on the recent NSTX divertor experiments and modeling with edge transport code UEDGE, a favorable basis for divertor power handling in NSTX-U is developed. The snowflake divertor geometry and feedback-controlled divertor impurity seeding applied to the lower and upper divertors are presently envisioned. In the NSTX snowflake experiments with lithium-coated graphite PFCs, the peak divertor heat fluxes from Type I ELMs and between ELMs were significantly reduced due to geometry effects, increased volumetric losses and null-point convective redistribution between strike points. H-mode core confinement was maintained at H98(y,2)<=1 albeit the radiative detachment. Additional CD4 seeding demonstrated potential for a further increase of divertor radiation.

  14. Mitigation of divertor heat loads by strike point sweeping in high power JET discharges

    Science.gov (United States)

    Silburn, S. A.; Matthews, G. F.; Challis, C. D.; Frigione, D.; Graves, J. P.; Mantsinen, M. J.; Belonohy, E.; Hobirk, J.; Iglesias, D.; Keeling, D. L.; King, D.; Kirov, K.; Lennholm, M.; Lomas, P. J.; Moradi, S.; Sips, A. C. C.; Tsalas, M.; Contributors, JET

    2017-12-01

    Deliberate periodic movement (sweeping) of the high heat flux divertor strike lines in tokamak plasmas can be used to manage the heat fluxes experienced by exhaust handling plasma facing components, by spreading the heat loads over a larger surface area. Sweeping has recently been adopted as a routine part of the main high performance plasma configurations used on JET, and has enabled pulses with 30 MW plasma heating power and 10 MW radiation to run for 5 s without overheating the divertor tiles. We present analysis of the effectiveness of sweeping for divertor temperature control on JET, using infrared camera data and comparison with a simple 2D heat diffusion model. Around 50% reduction in tile temperature rise is obtained with 5.4 cm sweeping compared to the un-swept case, and the temperature reduction is found to scale slower than linearly with sweeping amplitude in both experiments and modelling. Compatibility of sweeping with high fusion performance is demonstrated, and effects of sweeping on the edge-localised mode behaviour of the plasma are reported and discussed. The prospects of using sweeping in future JET experiments with up to 40 MW heating power are investigated using a model validated against existing experimental data.

  15. Mitigation of divertor heat loads by strike point sweeping in high power JET discharges

    International Nuclear Information System (INIS)

    Silburn, S A; Matthews, G F; Challis, C D; Belonohy, E; Iglesias, D; Keeling, D L; King, D; Kirov, K; Lomas, P J; Frigione, D; Graves, J P; Mantsinen, M J; Hobirk, J; Lennholm, M; Moradi, S; Sips, A C C; Tsalas, M

    2017-01-01

    Deliberate periodic movement (sweeping) of the high heat flux divertor strike lines in tokamak plasmas can be used to manage the heat fluxes experienced by exhaust handling plasma facing components, by spreading the heat loads over a larger surface area. Sweeping has recently been adopted as a routine part of the main high performance plasma configurations used on JET, and has enabled pulses with 30 MW plasma heating power and 10 MW radiation to run for 5 s without overheating the divertor tiles. We present analysis of the effectiveness of sweeping for divertor temperature control on JET, using infrared camera data and comparison with a simple 2D heat diffusion model. Around 50% reduction in tile temperature rise is obtained with 5.4 cm sweeping compared to the un-swept case, and the temperature reduction is found to scale slower than linearly with sweeping amplitude in both experiments and modelling. Compatibility of sweeping with high fusion performance is demonstrated, and effects of sweeping on the edge-localised mode behaviour of the plasma are reported and discussed. The prospects of using sweeping in future JET experiments with up to 40 MW heating power are investigated using a model validated against existing experimental data. (paper)

  16. Developing physics basis for the snowflake divertor in the DIII-D tokamak

    Science.gov (United States)

    Soukhanovskii, V. A.; Allen, S. L.; Fenstermacher, M. E.; Lasnier, C. J.; Makowski, M. A.; McLean, A. G.; Meyer, W. H.; Ryutov, D. D.; Kolemen, E.; Groebner, R. J.; Hyatt, A. W.; Leonard, A. W.; Osborne, T. H.; Petrie, T. W.; Watkins, J.

    2018-03-01

    Recent DIII-D results demonstrate that the snowflake (SF) divertor geometry (see standard divertor) enables significant manipulation of divertor heat transport for heat spreading and reduction in attached and radiative divertor regimes, between and during edge localized modes (ELMs), while maintaining good H-mode confinement. Snowflake divertor configurations have been realized in the DIII-D tokamak for several seconds in H-mode discharges with heating power P_NBI ≤slant 4 -5 MW and a range of plasma currents I_p=0.8-1.2 MA. In this work, inter-ELM transport and radiative SF divertor properties are studied. Significant impact of geometric properties on SOL and divertor plasma parameters, including increased poloidal magnetic flux expansion, divertor magnetic field line length and divertor volume, is confirmed. In the SF-minus configuration, heat deposition is affected by the geometry, and peak divertor heat fluxes are significantly reduced. In the SF-plus and near-exact SF configurations, divertor peak heat flux reduction and outer strike point heat flux profile broadening are observed. Inter-ELM sharing of power and particle fluxes between the main and additional snowflake divertor strike points has been demonstrated. The additional strike points typically receive up to 10-15% of total outer divertor power. Measurements of electron pressure and poloidal beta βp support the theoretically proposed churning mode that is driven by toroidal curvature and vertical pressure gradient in the weak poloidal field region. A comparison of the 4-4.5 MW NBI-heated H-mode plasmas with radiative SF divertor and the standard radiative divertor (both induced with additional gas puffing) shows a nearly complete power detachment and broader divertor radiated power distribution in the SF, as compared to a partial detachment and peaked localized radiation in the standard divertor. However, insignificant difference in the detachment onset w.r.t. density between the SF and the standard

  17. Experimental and analytical studies of high heat flux components for fusion experimental reactor

    International Nuclear Information System (INIS)

    Araki, Masanori

    1993-03-01

    In this report, the experimental and analytical results concerning the development of plasma facing components of ITER are described. With respect to developing high heat removal structures for the divertor plates, an externally-finned swirl tube was developed based on the results of critical heat flux (CHF) experiments on various tube structures. As the result, the burnout heat flux, which also indicates incident CHF, of 41 ± 1 MW/m 2 was achieved in the externally-finned swirl tube. The applicability of existing CHF correlations based on uniform heating conditions was evaluated by comparing the CHF experimental data with the smooth and the externally-finned tubes under one-sided heating condition. As the results, experimentally determined CHF data for straight tube show good agreement, for the externally-finned tube, no existing correlations are available for prediction of the CHF. With respect to the evaluation of the bonds between carbon-based material and heat sink metal, results of brazing tests were compared with the analytical results by three dimensional model with temperature-dependent thermal and mechanical properties. Analytical results showed that residual stresses from brazing can be estimated by the analytical three directional stress values instead of the equivalent stress value applied. In the analytical study on the separatrix sweeping for effectively reducing surface heat fluxes on the divertor plate, thermal response of the divertor plate has been analyzed under ITER relevant heat flux conditions and has been tested. As the result, it has been demonstrated that application of the sweeping technique is very effective for improvement in the power handling capability of the divertor plate and that the divertor mock-up has withstood a large number of additional cyclic heat loads. (J.P.N.) 62 refs

  18. Exploring the engineering limit of heat flux of a W/RAFM divertor target for fusion reactors

    Science.gov (United States)

    Mao, X.; Fursdon, M.; Chang, X. B.; Zhang, J. W.; Liu, P.; Ellwood, G.; Qian, X. Y.; Qin, S. J.; Peng, X. B.; Barrett, T. R.; Liu, P.

    2018-06-01

    The design and development of a fusion reactor divertor plasma facing component (PFC) is one of the many challenging issues on the road to commercial use of fusion energy. The divertor PFC is expected to exhaust steady state heat loads in the region of 10 MW m‑2 while keeping temperatures and thermo-mechanical stresses in its structure within the allowable limits. For ITER (International Thermo-Nuclear Experimental Reactor) a water cooled W/CuCrZr divertor PFC concept has been developed. However, this concept is not necessarily assured for use in future fusion reactors mainly because the neutron radiation dose would be at least an order magnitude higher, resulting in limited thermo-mechanical performance and considerably more activated waste products. In the present study, a water cooled divertor PFC using reduced activation ferritic-martensitic (RAFM) steel as the heat sink pipe has been designed with pressurised water reactor-like cooling conditions (pressure of 15.5 MPa, velocity of 10–20 m s‑1 and temperature of 300 °C). The PFC is made up of a number of rectangular tungsten tiles, each with an inner circular hole (so-called monoblocks), joined onto a RAFM steel pipe with copper interlayers. The thermo-mechanical performance of the PFC has been studied in detail. The heat transfer coefficient between the RAFM pipe inner surface and the water was calculated using published correlations. Geometric parameters and water velocity were optimized with finite element (FE) thermal analysis, to achieve acceptable temperatures in the structure given the target exhaust heat load of 10 MW m‑2. Under this heat load and the optimised thermal design parameters, the structure of the PFC was further assessed by mechanical analysis. We find that under these conditions the RAFM steel pipe experiences cyclic plasticity, and fails the common linear elastic ratchetting (3 Sm) rule. Nevertheless, the designed W/RAFM divertor PFU can withstand 10 MW m‑2 heat load, albeit

  19. Evaluating Stellarator Divertor Designs with EMC3

    Science.gov (United States)

    Bader, Aaron; Anderson, D. T.; Feng, Y.; Hegna, C. C.; Talmadge, J. N.

    2013-10-01

    In this paper various improvements of stellarator divertor design are explored. Next step stellarator devices require innovative divertor solutions to handle heat flux loads and impurity control. One avenue is to enhance magnetic flux expansion near strike points, somewhat akin to the X-Divertor concept in Tokamaks. The effect of judiciously placed external coils on flux deposition is calculated for configurations based on the HSX stellarator. In addition, we attempt to optimize divertor plate location to facilitate the external coil placement. Alternate areas of focus involve altering edge island size to elucidate the driving physics in the edge. The 3-D nature of stellarators complicates design and necessitates analysis of new divertor structures with appropriate simulation tools. We evaluate the various configurations with the coupled codes EMC3-EIRENE, allowing us to benchmark configurations based on target heat flux, impurity behavior, radiated power, and transitions to high recycling and detached regimes. Work supported by DOE-SC0006103.

  20. ARIES-III divertor engineering design

    International Nuclear Information System (INIS)

    Wong, C.P.C.; Schultz, K.R.; Cheng, E.T.; Grotz, S.; Hasan, M.A.; Najmabadi, F.; Sharafat, S.; Herring, J.S.; Valenti, M.; Steiner, D.

    1992-01-01

    This paper reports the engineering design of the ARIES-III double- null divertor. The divertor coolant tubes are made from W-3Re alloy and cooled by subcooled flow boiling of organic coolant. A coating of 4 mm thick tungsten is plasma sprayed onto the divertor surface. This W layer can withstand the thermal deposition of a few disruptions. At a maximum surface heat flux of 5.4 MW/m 2 , a conventional divertor design can be used. The divertor surface is contoured to have a constant heat flux of 5.4 MW/m 2 . The net erosion of the W-surface was found to be negligible at about 0.1 mm/year. After 3 years of operation, the W-3Re alloy ARIES-III divertor can be disposed of as Class A waste. In order to control the prompt dose release at site boundary to less than 200 Rem, isotopic tailoring of the W-alloy will be needed

  1. ARIES-III divertor engineering design

    Energy Technology Data Exchange (ETDEWEB)

    Wong, C.P.C.; Schultz, K.R. [General Atomics, San Diego, CA (United States); Cheng, E.T. [TSI Research, Solana Beach, CA (United States); Grotz, S.; Hasan, M.A.; Najmabadi, F.; Sharafat, S. [California Univ., Los Angeles, CA (United States). Dept. of Mechanical, Aerospace and Nuclear Engineering; Brooks, J.N.; Ehst, D.A.; Sze, D.K. [Argonne National Lab., IL (United States); Herring, J.S. [EG and G Idaho, Inc., Idaho Falls, ID (United States); Valenti, M.; Steiner, D. [Rensselaer Polytechnic Inst., Troy, NY (United States). Plasma Dynamics Lab.

    1992-01-01

    This paper reports the engineering design of the ARIES-III double- null divertor. The divertor coolant tubes are made from W-3Re alloy and cooled by subcooled flow boiling of organic coolant. A coating of 4 mm thick tungsten is plasma sprayed onto the divertor surface. This W layer can withstand the thermal deposition of a few disruptions. At a maximum surface heat flux of 5.4 MW/m{sup 2}, a conventional divertor design can be used. The divertor surface is contoured to have a constant heat flux of 5.4 MW/m{sup 2}. The net erosion of the W-surface was found to be negligible at about 0.1 mm/year. After 3 years of operation, the W-3Re alloy ARIES-III divertor can be disposed of as Class A waste. In order to control the prompt dose release at site boundary to less than 200 Rem, isotopic tailoring of the W-alloy will be needed.

  2. Divertor ‘death-ray’ explained: An artifact of a Langmuir probe operating at negative bias in a high-recycling divertor

    International Nuclear Information System (INIS)

    Brunner, D.; Umansky, M.V.; LaBombard, B.; Rognlien, T.D.

    2013-01-01

    The divertor ‘death-ray’, enhanced plasma pressure near the outer strike-point relative to ‘upstream’ values, was thought to correspond to axisymmetric increased divertor heat flux. Recent measurements on Alcator C-Mod show that the ‘death-ray’ is localized to biased Langmuir probes. Heat fluxes deduced from plasma-sheath theory and surface thermocouples agree in sheath-limited and moderate-recycling regimes. They diverge in high-recycling and detached regimes; surface thermocouples measure reduced heat flux while a ‘death-ray’ appears on Langmuir probes. The ‘death-ray’ is caused by the probe’s negative bias affecting the local flux tube. With the bias, electron heat flux to the probe surface is reduced. Thus, the local electron temperature is raised, enhancing neutral ionization and increasing the ion flux to the probe. The plasma fluid code UEDGE is used to simulate and reproduce many of the features of this integrated biased probe/divertor system

  3. Numerical Simulation on Subcooled Boiling Heat Transfer Characteristics of Water-Cooled W/Cu Divertors

    Science.gov (United States)

    Han, Le; Chang, Haiping; Zhang, Jingyang; Xu, Tiejun

    2015-04-01

    In order to realize safe and stable operation of a water-cooled W/Cu divertor under high heating condition, the exact knowledge of its subcooled boiling heat transfer characteristics under different design parameters is crucial. In this paper, subcooled boiling heat transfer in a water-cooled W/Cu divertor was numerically investigated based on computational fluid dynamic (CFD). The boiling heat transfer was simulated based on the Euler homogeneous phase model, and local differences of liquid physical properties were considered under one-sided high heating conditions. The calculated wall temperature was in good agreement with experimental results, with the maximum error of 5% only. On this basis, the void fraction distribution, flow field and heat transfer coefficient (HTC) distribution were obtained. The effects of heat flux, inlet velocity and inlet temperature on temperature distribution and pressure drop of a water-cooled W/Cu divertor were also investigated. These results provide a valuable reference for the thermal-hydraulic design of a water-cooled W/Cu divertor. supported by the National Magnetic Confinement Fusion Science Program of China (No. 2010GB104005), Funding of Jiangsu Innovation Program for Graduate Education (CXLX12_0170), the Fundamental Research Funds for the Central Universities of China

  4. Advantages and Challenges of Radiative Liquid Lithium Divertor

    Science.gov (United States)

    Ono, Masayuki

    2017-10-01

    Steady-state fusion power plant designs present major divertor technology challenges, including high divertor heat flux both in steady-state and during transients. In addition to these concerns, there are the unresolved technology issues of long term dust accumulation and associated tritium inventory and safety issues. The application of lithium (Li) in NSTX resulted in improved H-mode confinement, H-mode power threshold reduction, and reduction in the divertor peak heat flux while maintaining essentially Li-free core plasma operation even during H-modes. These promising results in NSTX and related modeling calculations motivated the radiative liquid Li divertor (RLLD) concept and its variant, the active liquid Li divertor concept (ARLLD), taking advantage of the enhanced Li radiation in relatively poorly confined divertor plasmas. It has been suggested that radiation-based liquid lithium (LL) divertor concepts with a modest Li-loop could provide a possible solution for the outstanding fusion reactor technology issues such as divertor heat flux mitigation and real time dust removal, while potentially improving the reactor plasma performance. Laboratory tests are also planned to investigate the Li-T recover efficiency and other relevant research topics of the RLLD. This work supported by DoE Contract No. DE-AC02-09CH11466.

  5. Comparison of heat flux measurement techniques during the DIII-D metal ring campaign

    Science.gov (United States)

    Barton, J. L.; Nygren, R. E.; Unterberg, E. A.; Watkins, J. G.; Makowski, M. A.; Moser, A.; Rudakov, D. L.; Buchenauer, D.

    2017-12-01

    The heat fluxes expected in the ITER divertor raise concerns about the damage tolerances of tungsten, especially due to thermal transients caused by edge localized modes (ELMs) as well as frequent temperature cycling from high to low extremes. Therefore we are motivated to understand the heat flux conditions that can cause not only enhanced erosion but also bulk thermo-mechanical damage to a tungsten divertor. For the metal ring campaign in DIII-D, tungsten-coated TZM tile inserts were installed making two toroidal arrays of metal tile inserts in the lower divertor. This study examines the deposited heat flux on these rings with embedded thermocouples (TCs) sampling at 10 kHz and compares them to Langmuir probe (LP) and infrared thermography (IRTV) heat flux measurements. We see agreement of the TC, LP, and IRTV data within 20% of the heat flux averaged over the entire discharge, and that all three diagnostics suggest parallel heat flux at the OSP location increases linearly with input heating power. The TC and LP heat flux time traces during the discharge trend together during large changes to the average heat flux. By subtracting the LP measured inter-ELM heat flux from TC data, using a rectangular ELM energy pulse shape, and taking the relative size and duration of each ELM from {{D}}α measurements, we extract the ELM heat fluxes from TC data. This over-estimates the IRTV measured ELM heat fluxes by a factor of 1.9, and could be due to the simplicity of the TC heat flux model and the assumed ELM energy pulse shape. ELM heat fluxes deposited on the inserts are used to model tungsten erosion in this campaign. These TC ELM heat flux estimates are used in addition to IRTV, especially in cases where the IRTV view to the metal ring is obstructed. We observe that some metal inserts were deformed due to exposed leading edges. The thermal conditions on these inserts are investigated with the thermal modeling code ABAQUS using our heat flux measurements when these edges

  6. Modeling detachment physics in the NSTX snowflake divertor

    Energy Technology Data Exchange (ETDEWEB)

    Meier, E.T., E-mail: emeier@wm.edu [Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States); Soukhanovskii, V.A. [Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States); Bell, R.E.; Diallo, A.; Kaita, R.; LeBlanc, B.P. [Princeton Plasma Physics Laboratory, Princeton, NJ 08540 (United States); McLean, A.G. [Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States); Podestà, M. [Princeton Plasma Physics Laboratory, Princeton, NJ 08540 (United States); Rognlien, T.D.; Scotti, F. [Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States)

    2015-08-15

    The snowflake divertor is a proposed technique for coping with the tokamak power exhaust problem in next-step experiments and eventually reactors, where extreme power fluxes to material surfaces represent a leading technological and physics challenge. In lithium-conditioned National Spherical Torus Experiment (NSTX) discharges, application of the snowflake divertor typically induced partial outer divertor detachment and severalfold heat flux reduction. UEDGE is used to analyze and compare conventional and snowflake divertor configurations in NSTX. Matching experimental upstream profiles and divertor measurements in the snowflake requires target recycling of 0.97 vs. 0.91 in the conventional case, implying partial saturation of the lithium-based pumping mechanism. Density scans are performed to analyze the mechanisms that facilitate detachment in the snowflake, revealing that increased divertor volume provides most of the parallel heat flux reduction. Also, neutral gas power loss is magnified by the increased wetted area in the snowflake, and plays a key role in generating volumetric recombination.

  7. Radiative divertor plasmas with convection in DIII-D

    International Nuclear Information System (INIS)

    Leornard, A.W.; Porter, G.D.; Wood, R.D.

    1998-01-01

    The radiation of divertor heat flux on DIII-D is shown to greatly exceed the limits imposed by assumptions of energy transport dominated by electron thermal conduction parallel to the magnetic field. Approximately 90% of the power flowing into the divertor is dissipated through low Z radiation and plasma recombination. The dissipation is made possible by an extended region of low electron temperature in the divertor. A one-dimensional analysis of the parallel heat flux finds that the electron temperature profile is incompatible with conduction dominated parallel transport. Plasma flow at up to the ion acoustic speed, produced by upstream ionization, can account for the parallel heat flux. Modeling with the two-dimensional fluid code UEDGE has reproduced many of the observed experimental features

  8. X-Divertor Geometries for Deeper Detachment Without Degrading the DIII-D H-Mode

    Science.gov (United States)

    Covele, Brent; Kotschenreuther, M. T.; Valanju, P. M.; Mahajan, S. M.; Leonard, A. W.; Hyatt, A. W.; McLean, A. G.; Thomas, D. M.; Guo, H. Y.; Watkins, J. G.; Makowski, M. A.; Hill, D. N.

    2015-11-01

    Recent DIII-D experiments comparing the standard divertor (SD) and X-Divertor (XD) geometries show heat and particle flux reduction at the divertor target plate. The XD features large poloidal flux expansion, increased connection length, and poloidal field line flaring, quantified by the Divertor Index. Both SD and XD were pushed deep into detachment with increased gas puffing, until core energy confinement and pedestal pressure were substantially reduced. As expected, outboard target heat fluxes are significantly reduced in the XD compared to the SD under similar upstream plasma conditions, even at low Greenwald fraction. The high-triangularity (floor) XD cases show larger reduction in temperature, heat, and particle flux relative to the SD in all cases, while low-triangularity (shelf) XD cases show more modest reductions over the SD. Consequently, heat flux reduction and divertor detachment may be achieved in the XD with less gas puffing and higher pedestal pressures. Further causative analysis, as well as detailed modeling with SOLPS, is underway. These initial experiments suggest the XD as a promising candidate to achieve divertor heat flux control compatible with robust H-mode operation. Work supported by US DOE under DE-FC02-04ER54698, DE-AC52-07NA27344, DE-FG02-04ER54754, and DE-FG02-04ER54742.

  9. Finite element based design optimization of WENDELSTEIN 7-X divertor components under high heat flux loading

    International Nuclear Information System (INIS)

    Plankensteiner, A.; Leuprecht, A.; Schedler, B.; Scheiber, K.-H.; Greuner, H.

    2007-01-01

    In the divertor of the nuclear fusion experiment WENDELSTEIN 7-X (W7-X) plasma facing high heat flux target elements have to withstand severe loading conditions. The thermally induced mechanical stressing turns out to be most critical with respect to lifetime predictions of the target elements. Therefore, different design variants of those CFC flat tile armoured high heat flux components have been analysed via the finite element package ABAQUS aiming at derivation of an optimized component design under high heat flux conditions. The investigated design variants comprise also promising alterations in the cooling channel design and castellation of the CFC flat tiles which, however, from a system integration and manufacturing standpoint of view, respectively, are evaluated to be critical. Therefore, the numerical study as presented here mainly comprises a reference variant that is comparatively studied with a variant incorporating a bi-layer-type AMC-Cu/OF-Cu interlayer at the CFC/Cu-interface. The thermo-mechanical material characteristics are accounted for in the finite element models with elastic-plastic properties being assigned to the metallic sections CuCrZr, AMC-Cu and OF-Cu, respectively, and orthotropic nonlinear-elastic properties being used for the CFC sections. The calculated temporal and spatial evolution of temperatures, stresses, and strains for the individual design variants are evaluated with special attention being paid to stress measures, plastic strains, and damage parameters indicating the risk of failure of CFC and the CFC/Cu-interface, respectively. This way the finite element analysis allows to numerically derive an optimized design variant within the framework of expected operating conditions in W7-X

  10. Particle and power deposition on divertor targets in EAST H-mode plasmas

    International Nuclear Information System (INIS)

    Wang, L.; Xu, G.S.; Guo, H.Y.; Chen, R.; Ding, S.; Gan, K.F.; Gao, X.; Gong, X.Z.; Jiang, M.; Liu, P.; Liu, S.C.; Luo, G.N.; Ming, T.F.; Wan, B.N.; Wang, D.S.; Wang, F.M.; Wang, H.Q.; Wu, Z.W.; Yan, N.; Zhang, L.

    2012-01-01

    The effects of edge-localized modes (ELMs) on divertor particle and heat fluxes were investigated for the first time in the Experimental Advanced Superconducting Tokamak (EAST). The experiments were carried out with both double null and lower single null divertor configurations, and comparisons were made between the H-mode plasmas with lower hybrid current drive (LHCD) and those with combined ion cyclotron resonance heating (ICRH). The particle and heat flux profiles between and during ELMs were obtained from Langmuir triple-probe arrays embedded in the divertor target plates. And isolated ELMs were chosen for analysis in order to reduce the uncertainty resulting from the influence of fast electrons on Langmuir triple-probe evaluation during ELMs. The power deposition obtained from Langmuir triple probes was consistent with that from the divertor infra-red camera during an ELM-free period. It was demonstrated that ELM-induced radial transport predominantly originated from the low-field side region, in good agreement with the ballooning-like transport model and experimental results of other tokamaks. ELMs significantly enhanced the divertor particle and heat fluxes, without significantly broadening the SOL width and plasma-wetted area on the divertor target in both LHCD and LHCD + ICRH H-modes, thus posing a great challenge for the next-step high-power, long-pulse operation in EAST. Increasing the divertor-wetted area was also observed to reduce the peak heat flux and particle recycling at the divertor target, hence facilitating long-pulse H-mode operation. The particle and heat flux profiles during ELMs appeared to exhibit multiple peak structures, and were analysed in terms of the behaviour of ELM filaments and the flux tubes induced by modified magnetic topology during ELMs. (paper)

  11. Effects of divertor geometry and pumping on plasma performance on DIII-D

    International Nuclear Information System (INIS)

    Allen, S.L.; Hill, D.N.; Porter, G.D.

    1997-06-01

    This paper reports the status of an ongoing investigation to discern the influence of the divertor and plasma geometry on the confinement of both ELM-free and ELMing discharges in DIII-D. The ultimate goal is to achieve a high-performance core plasma which coexists with an advanced divertor plasma. The divertor plasma must reduce the heat flux to acceptable levels; the current technique disperses the heat flux over a wide area by radiation (a radiative divertor). To date, we have obtained our best performance in double-null (DN) high-triangularity (δ ∼ 0.8) ELM-free discharges. As discussed in detail elsewhere, there are several advantages for both the core and divertor plasma with highly-shaped DN operation. Previous radiative-divertor experiments with D 2 injection in DN high-δ ELMing H-mode have shown that this configuration is more sensitive to gas puffing (τ decreases). Moving the X-point away from the target plate (to ∼15 cm above the plate) decreases this sensitivity. Preliminary measurements also indicate that gas puffing reduces the divertor heat flux but does not reduce the plasma pressure along the field line. The up/down heat flux balance can be varied magnetically (by changing the distance between the separatrices), with a slight magnetic imbalance required to balance the heat flux. The overall mission of the Radiative Divertor Project (RDP) is to install a fully pumped and baffled high-δ DN divertor. To date, however, both the DIII-D divertor diagnostics and pump were optimized for lower single-null (LSN) low-δ (δ∼ 0.4) plasmas, so much of the divertor physics has been performed in LSN; these results are discussed in Section 2. As part of the first phase of the RDP, we have installed a new high-δ USN divertor baffle and pump; these results are discussed in Section 3. Both divertor and core parameters are discussed in each case

  12. Design and analysis of the W7-X divertor scraper element

    International Nuclear Information System (INIS)

    Lumsdaine, A.; Tipton, J.; Lore, J.; McGinnis, D.; Canik, J.; Harris, J.; Peacock, A.; Boscary, J.; Tretter, J.; Andreeva, T.

    2013-01-01

    Highlights: • A high heat flux actively cooled divertor component is thermally modeled with CFD. • CFC monoblocks are analyzed to verify peak steady-state temperatures do not exceed 1200 °C. • A field line diffusion code is developed to determine the heat flux on the divertor components. • Iteration is required to develop a surface that meets the criteria and fits into the limited space. -- Abstract: Thehigh heat-flux divertor of the Wendelstein 7-X large stellarator experiment consists of 10 divertor units which are designed to carry a steady-state heat flux of 10 MW/m 2 . However, the edge elements of this divertor are limited to only 5 MW/m 2 , and may be overloaded in certain plasma scenarios. It is proposed to reduce this heat by placing an additional “scraper element” in each of the ten divertor locations. It will be constructed using carbon fiber composite (CFC) monoblock technology. The design of the monoblocks and the path of the cooling tubes must be optimized in order to survive the significant steady-state heat loads, provide adequate coverage for the existing divertor, be located within sub-millimeter accuracy, and take into account the boundaries to other in vessel components, all at a minimum cost. Computational fluid dynamics modeling has been performed to examine the thermal transfer through the monoblock swirl tube channels for the design of the monoblock orientation. An iterative physics modeling and computer aided design process is being performed to optimize the placement of the scraper element within the severe spatial restrictions

  13. High temperature divertor plasma operation

    International Nuclear Information System (INIS)

    Ohyabu, Nobuyoshi.

    1991-02-01

    High temperature divertor plasma operation has been proposed, which is expected to enhance the core energy confinement and eliminates the heat removal problem. In this approach, the heat flux is guided through divertor channel to a remote area with a large target surface, resulting in low heat load on the target plate. This allows pumping of the particles escaping from the core and hence maintaining of the high divertor temperature, which is comparable to the core temperature. The energy confinement is then determined by the diffusion coefficient of the core plasma, which has been observed to be much lower than the thermal diffusivity. (author)

  14. Operating conditions of the BPX divertor

    International Nuclear Information System (INIS)

    Hill, D.N.; Milovich, J.; Rognlien, T.; Braams, B.J.; Brooks, J.N.; Campbell, R.; Haines, J.; Knoll, D.; Prinja, A.; Stotler, D.P.; Ulrickson, M.

    1991-01-01

    In this paper we discuss the expected operating conditions at the divertor of the BPX tokamak (Burning Plasma Experiment), the next- step US tokamak proposed for the study of self-heated plasmas at Q ≅ 5 to ignition. In this double-null device (κ ≅ 2), the predicted first-wall loading is high because of is compact size (R = 2.6m, α = 0.8m, I p = 10.6 MA, and B T ) and its high projected fusion power output (100--500 MW with up to 20 MW of ICRH). Present designs call for inertially cooled carbon-based target plate material and X-point sweeping to handle the divertor heat flux during the 3--5 s flat-top at full power. The X-point is maintained about 15--20 cm off the target plates (a distance of ∼5m along field lines), which represents a reasonable compromise between lowering the divertor electron temperature (T e,d ) by increasing the connection length, and lowering the peak divertor heat flux (q d ) by increasing the magnetic flux expansion (which is about 15--20 in this case). It is planned for the BPX device to operate with H-mode confinement; ELMs are expected because of the relatively high power flow through the edge plasma (P sep ≅ 0.6 MW/m 2 for P fus = 500 MW). The ELMs will help reduce the impurity concentration in the core plasma (Z eff ≅ 1.7) and keep the density down, but should not add significantly to the divertor heat flux since their measured contribution to the global power balance drops with increasing input power

  15. Engineering design of the Aries-IV gaseous divertor

    International Nuclear Information System (INIS)

    Hasan, M.Z.; Najmabadi, F.; Sharafat, S.

    1994-01-01

    ARIES-IV is a conceptual, D-T burning, steady-state tokamak fusion reactor producing 1000 MWe net. It operates in the second plasma stability regime. The structural material is SiC composite and the primary coolant is helium at 10MPa base pressure. ARIES-IV uses double-null divertors for particle control. Total thermal power recovered from the divertors is 425MW, which is 16% of the total reactor thermal power. Among the desirable goals of divertor design were to avoid the use of tungsten and to use the same structural material and primary coolant as in the blanket design. In order to reduce peak heat flux, the innovative gaseous divertor has been used in ARIES-IV. A gaseous divertor reduces peak heat flux by increasing the surface area and by distributing particle and radiation energy more uniformly. Another benefit of gaseous divertor is the reduction of plasma temperature in the divertor chamber, so that material erosion due to sputtering, can be diminished. This makes the use of low-Z material possible in a gaseous divertor

  16. He-cooled divertor development for DEMO

    International Nuclear Information System (INIS)

    Norajitra, P.; Giniyatulin, R.; Ihli, T.; Janeschitz, G.; Krauss, W.; Kruessmann, R.; Kuznetsov, V.; Mazul, I.; Widak, V.; Ovchinnikov, I.; Ruprecht, R.; Zeep, B.

    2007-01-01

    Goal of the He-cooled divertor development for future fusion power plants is to resist a high heat flux of at least 10 MW/m 2 . The development includes the fields of design, analyses, and experiments. A helium-cooled modular jet concept (HEMJ) has been defined as reference solution, which is based on jet impingement cooling. In cooperation with the Efremov Institute, work was aimed at construction and high heat flux tests of prototypical tungsten mockups to demonstrate their manufacturability and their performances. A helium loop was built for this purpose to simulate the realistic thermo-hydraulics conditions close to those of DEMO (10 MPa He, 600 deg. C). The first high heat flux test results confirm the feasibility and the performance of the divertor design

  17. Plasma–Surface Interactions Under High Heat and Particle Fluxes

    Directory of Open Access Journals (Sweden)

    Gregory De Temmerman

    2013-01-01

    Full Text Available The plasma-surface interactions expected in the divertor of a future fusion reactor are characterized by extreme heat and particle fluxes interacting with the plasma-facing surfaces. Powerful linear plasma generators are used to reproduce the expected plasma conditions and allow plasma-surface interactions studies under those very harsh conditions. While the ion energies on the divertor surfaces of a fusion device are comparable to those used in various plasma-assited deposition and etching techniques, the ion (and energy fluxes are up to four orders of magnitude higher. This large upscale in particle flux maintains the surface under highly non-equilibrium conditions and bring new effects to light, some of which will be described in this paper.

  18. Development of database for the divertor recycling in JT-60U and its analysis

    Energy Technology Data Exchange (ETDEWEB)

    Takizuka, Tomonori; Shimizu, Katsuhiro; Hayashi, Nobuhiko; Asakura, Nobuyuki [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Arakawa, Kazuya [Komatsu, Ltd., Tokyo (Japan)

    2003-05-01

    We have developed a database for the divertor recycling in JT-60U plasmas. This database makes it possible to investigate behaviors of the neutral-particle flux in plasmas and the ion flux to divertor plates under a condition for core-plasma parameters, such as electron density and heating power. The correlation between the electron density and the heating power is not strong in this database, and parameter scans for the density and the power in wide ranges are realized. On the basis of this database, we have analyzed the ion flux to divertor plates. The divertor-plate ion flux amplified by the recycling grows nonlinearly with the increase of the electron density n{sub e}. Its averaged dependence is a linear growth ({approx}n{sub e}{sup 1.0}) at the low density, and becomes a nonlinear growth ({approx}n{sub e}{sup 1.5}) at the high density. The spread of dependence from the averaged one is very large. This spread is caused mainly by complex physical characteristics of divertor plasmas, though it is little dependent on the heating power. The behavior of ion flux depends strongly on divertor configurations and divertor-plate/first-wall conditions. It is confirmed that the bifurcated transition takes place from the low-recycling divertor plasma at the low density to the high-recycling divertor plasma at the high density. The density at the transition is nearly proportional to the 1/4 power of the heating power. (author)

  19. Prototyping phase of the high heat flux scraper element of Wendelstein 7-X

    Energy Technology Data Exchange (ETDEWEB)

    Boscary, J., E-mail: jean.boscary@ipp.mpg.de [Max Planck Institute for Plasma Physics, Garching (Germany); Greuner, H. [Max Planck Institute for Plasma Physics, Garching (Germany); Ehrke, G. [Max Planck Institute for Plasma Physics, Greifswald (Germany); Böswirth, B.; Wang, Z. [Max Planck Institute for Plasma Physics, Garching (Germany); Clark, E. [University of Tennessee, Knoxville (United States); Lumsdaine, A. [Oak Ridge National Laboratory, USA National Laboratory, Oak Ridge, Tennessee (United States); Tretter, J. [Max Planck Institute for Plasma Physics, Garching (Germany); McGinnis, D.; Lore, J. [Oak Ridge National Laboratory, USA National Laboratory, Oak Ridge, Tennessee (United States); Ekici, K. [University of Tennessee, Knoxville (United States)

    2016-11-01

    Highlights: • Aim of scraper element: reduction of heat loads on high heat flux divertor ends. • Design: actively water-cooled for 20 MW/m{sup 2} local heat loads. • Technology: CFC NB31 monoblocks bonded by HIP to CuCrZr cooling tube. • Successful high heat flux testing up to 20 MW/m{sup 2}. - Abstract: The water-cooled high heat flux scraper element aims to reduce excessive heat loads on the target element ends of the actively cooled divertor of Wendelstein 7-X. Its purpose is to intercept some of the plasma fluxes both upstream and downstream before they reach the divertor surface. The scraper element has 24 identical plasma facing components (PFCs) divided into 6 modules. One module has 4 PFCs hydraulically connected in series by 2 water boxes. A PFC, 247 mm long and 28 mm wide, has 13 monoblocks made of CFC NB31 bonded by hot isostatic pressing onto a CuCrZr cooling tube equipped with a copper twisted tape. 4 full-scale prototypes of PFCs have been successfully tested in the GLADIS facility up to 20 MW/m{sup 2}. The difference observed between measured and calculated surface temperatures is probably due to the inhomogeneity of CFC properties. The design of the water box prototypes has been detailed to allow the junction between the cooling pipe of the PFCs and the water boxes by internal orbital welding. The prototypes are presently under fabrication.

  20. Multi-Fluid Modeling of Low-Recycling Divertor Regimes

    International Nuclear Information System (INIS)

    Smirnov, R.D.; Pigarov, A.Y.; Krasheninnikov, S.I.; Rognlien, T.D.; Soukhanovskii, V.A.; Rensink, M.E.; Maingi, R.; Skinner, C.H.; Stotler, D.P.; Bell, R.E.; Kugel, H.W.

    2010-01-01

    The low-recycling regimes of divertor operation in a single-null NSTX magnetic configuration are studied using computer simulations with the edge plasma transport code UEDGE. The edge plasma transport properties pertinent to the low-recycling regimes are demonstrated. These include the flux-limited character of the parallel heat transport and the high plasma temperatures with the flattened profiles in the scrape-off-layer. It is shown that to maintain the balance of particle fluxes at the core interface the deuterium gas puffing rate should increase as the divertor recycling coefficient decreases. The radial profiles of the heat load to the outer divertor plate, the upstream radial plasma profiles, and the effects of the cross-field plasma transport in the low-recycling regimes are discussed. It is also shown that recycling of lithium impurities evaporating from the divertor plate at high surface temperatures can reverse the low-recycling divertor operational regime to the high-recycling one and may cause thermal instability of the divertor plate.

  1. Divertor modelling for conceptual studies of tokamak fusion reactor FDS-III

    International Nuclear Information System (INIS)

    Chen Yiping; Liu Songlin

    2010-01-01

    Divertor modelling for the conceptual studies of tokamak fusion reactor FDS-III was carried out by using the edge plasma code package B2.5-Eirene (SOLPS5.0). The modelling was performed by taking real MHD equilibrium and divertor geometry of the reactor into account. The profiles of plasma temperature, density and heat fluxes in the computational region and at the target plates have been obtained. The modelling results show that, with the fusion power P fu =2.6 GW and the edge density N edge =6.0x10 19 l/m 3 , the peak values of electron and ion heat fluxes at the outer target plate of divertor are respectively 93.92 MW/m 2 and 58.50 MW/m 2 . According to the modelling results it is suggested that some methods for reducing the heat fluxes at the target plates should be used in order to get acceptable level of power flux at the target plates for the divertor design of the reactor.

  2. Turbulent Simulations of Divertor Detachment Based On BOUT + + Framework

    Science.gov (United States)

    Chen, Bin; Xu, Xueqiao; Xia, Tianyang; Ye, Minyou

    2015-11-01

    China Fusion Engineering Testing Reactor is under conceptual design, acting as a bridge between ITER and DEMO. The detached divertor operation offers great promise for a reduction of heat flux onto divertor target plates for acceptable erosion. Therefore, a density scan is performed via an increase of D2 gas puffing rates in the range of 0 . 0 ~ 5 . 0 ×1023s-1 by using the B2-Eirene/SOLPS 5.0 code package to study the heat flux control and impurity screening property. As the density increases, it shows a gradually change of the divertor operation status, from low-recycling regime to high-recycling regime and finally to detachment. Significant radiation loss inside the confined plasma in the divertor region during detachment leads to strong parallel density and temperature gradients. Based on the SOLPS simulations, BOUT + + simulations will be presented to investigate the stability and turbulent transport under divertor plasma detachment, particularly the strong parallel gradient driven instabilities and enhanced plasma turbulence to spread heat flux over larger surface areas. The correlation between outer mid-plane and divertor turbulence and the related transport will be analyzed. Prepared by LLNL under Contract DE-AC52-07NA27344. LLNL-ABS-675075.

  3. Divertor IR thermography on Alcator C-Moda)

    Science.gov (United States)

    Terry, J. L.; LaBombard, B.; Brunner, D.; Payne, J.; Wurden, G. A.

    2010-10-01

    Alcator C-Mod is a particularly challenging environment for thermography. It presents issues that will similarly face ITER, including low-emissivity metal targets, low-Z surface films, and closed divertor geometry. In order to make measurements of the incident divertor heat flux using IR thermography, the C-Mod divertor has been modified and instrumented. A 6° toroidal sector has been given a 2° toroidal ramp in order to eliminate magnetic field-line shadowing by imperfectly aligned divertor tiles. This sector is viewed from above by a toroidally displaced IR camera and is instrumented with thermocouples and calorimeters. The camera provides time histories of surface temperatures that are used to compute incident heat-flux profiles. The camera sensitivity is calibrated in situ using the embedded thermocouples, thus correcting for changes and nonuniformities in surface emissivity due to surface coatings.

  4. Dynamic behavior of detached recombining plasmas during ELM-like plasma heat pulses in the divertor plasma simulator NAGDIS-II

    International Nuclear Information System (INIS)

    Uesugi, Y.; Hattori, N.; Nishijima, D.; Ohno, N.; Takamura, S.

    2001-01-01

    It has been recognized that the ELMs associated with a good confinement at the edge, such as H-mode, must bring an enormous energy to the divertor target plate through SOL and detached plasmas. The understanding of the ELM energy transport through SOL to the divertor target is rather poor at the moment, which leads to an ambiguous estimation of the deposited heat load on the divertor target in ITER. In the present work the ELM-like plasma heat pulse is generated by rf heating in a linear divertor plasma simulator. Energetic electrons with an energy range 10-40 eV are effectively generated by rf heating in low temperature plasmas with (T e )< ∼1 eV. It is observed experimentally that the energetic electrons ionize the highly excited Rydberg atoms quickly, bringing a rapid increase of the ion particle flux to the target, and make the detached plasmas attached to the target. Detailed physical processes about the interaction between the heat pulse with conduction and convection, and detached recombining plasmas are discussed

  5. Characteristics of divertor plasma and scrape-off layer in JT-60U

    International Nuclear Information System (INIS)

    Itami, K.; Shimada, M.; Hosogane, N.

    1992-01-01

    Heat flux to the divertor is measured by thermography and the heat transport in the scrape-off layer is studied in beam heated discharges of JT-60U. The heat flux onto the divertor is ∝50% of total beam power at maximum. The in-out asymmetry of the heat flux P HEAT in /P HEAT out is as large as 20-40% when the ion grad-B drift is toward the divertor. Differences in P HEAT in /P HEA T out due to the direction of ion grad-B drift are as large as large as ∝40%. A scaling of the peaking factor Y of heat flux, defined by Y=2πRfq max /P HEAT , is obtained for beam heated discharges in JT-60U with a wide range of plasma parameters. The Y corresponds to the inverse of the thickness of the scrape-off layer. From a statistical analysis, it is found that the peaking factor Y of heat flux scales as P HEAT 0.49±0.18 anti n e -0.45±0.22 q eff -0.67±0.18 . (orig.)

  6. ELM induced divertor heat loads on TCV

    Energy Technology Data Exchange (ETDEWEB)

    Marki, J., E-mail: janos.marki@epfl.c [Centre de Recherches en Physique des Plasmas (CRPP), Ecole Polytechnique Federale de Lausanne (EPFL), Association Euratom - Confederation Suisse, CH-1015 Lausanne (Switzerland); Pitts, R.A. [Centre de Recherches en Physique des Plasmas (CRPP), Ecole Polytechnique Federale de Lausanne (EPFL), Association Euratom - Confederation Suisse, CH-1015 Lausanne (Switzerland); Horacek, J. [Institute of Plasma Physics, Association EUROATOM-IPP.CR, Za Slovankou 3, 182 00 Prague 8 (Czech Republic); Tskhakaya, D. [Association EURATOM-OAW, Institut fuer Theoretische Physik, A-6020 Innsbruck (Austria)

    2009-06-15

    Results are presented for heat loads at the TCV outer divertor target during ELMing H-mode using a fast IR camera. Benefitting from a recent surface cleaning of the entire first wall graphite armour, a comparison of the transient thermal response of freshly cleaned and untreated tile surfaces (coated with thick co-deposited layers) has been performed. The latter routinely exhibit temperature transients exceeding those of the clean ones by a factor approx3, even if co-deposition throughout the first days of operation following the cleaning process leads to the steady regrowth of thin layers. Filaments are occasionally observed during the ELM heat flux rise phase, showing a spatial structure consistent with energy release at discrete toroidal locations in the outer midplane vicinity and with individual filaments carrying approx1% of the total ELM energy. The temporal waveform of the ELM heat load is found to be in good agreement with the collisionless free streaming particle model.

  7. ELM induced divertor heat loads on TCV

    Science.gov (United States)

    Marki, J.; Pitts, R. A.; Horacek, J.; Tskhakaya, D.; TCV Team

    2009-06-01

    Results are presented for heat loads at the TCV outer divertor target during ELMing H-mode using a fast IR camera. Benefitting from a recent surface cleaning of the entire first wall graphite armour, a comparison of the transient thermal response of freshly cleaned and untreated tile surfaces (coated with thick co-deposited layers) has been performed. The latter routinely exhibit temperature transients exceeding those of the clean ones by a factor ˜3, even if co-deposition throughout the first days of operation following the cleaning process leads to the steady regrowth of thin layers. Filaments are occasionally observed during the ELM heat flux rise phase, showing a spatial structure consistent with energy release at discrete toroidal locations in the outer midplane vicinity and with individual filaments carrying ˜1% of the total ELM energy. The temporal waveform of the ELM heat load is found to be in good agreement with the collisionless free streaming particle model.

  8. Plasma-surface interactions under high heat and particle fluxes

    NARCIS (Netherlands)

    De Temmerman, G.; Bystrov, K.; Liu, F.; Liu, W.; Morgan, T.; Tanyeli, I.; van den Berg, M.; Xu, H.; Zielinski, J.

    2013-01-01

    The plasma-surface interactions expected in the divertor of a future fusion reactor are characterized by extreme heat and particle fluxes interacting with the plasma-facing surfaces. Powerful linear plasma generators are used to reproduce the expected plasma conditions and allow plasma-surface

  9. The heat removal capability of actively cooled plasma-facing components for the ITER divertor

    Science.gov (United States)

    Missirlian, M.; Richou, M.; Riccardi, B.; Gavila, P.; Loarer, T.; Constans, S.

    2011-12-01

    Non-destructive examination followed by high-heat-flux testing was performed for different small- and medium-scale mock-ups; this included the most recent developments related to actively cooled tungsten (W) or carbon fibre composite (CFC) armoured plasma-facing components. In particular, the heat-removal capability of these mock-ups manufactured by European companies with all the main features of the ITER divertor design was investigated both after manufacturing and after thermal cycling up to 20 MW m-2. Compliance with ITER requirements was explored in terms of bonding quality, heat flux performances and operational compatibility. The main results show an overall good heat-removal capability after the manufacturing process independent of the armour-to-heat sink bonding technology and promising behaviour with respect to thermal fatigue lifetime under heat flux up to 20 MW m-2 for the CFC-armoured tiles and 15 MW m-2 for the W-armoured tiles, respectively.

  10. The heat removal capability of actively cooled plasma-facing components for the ITER divertor

    International Nuclear Information System (INIS)

    Missirlian, M; Richou, M; Loarer, T; Riccardi, B; Gavila, P; Constans, S

    2011-01-01

    Non-destructive examination followed by high-heat-flux testing was performed for different small- and medium-scale mock-ups; this included the most recent developments related to actively cooled tungsten (W) or carbon fibre composite (CFC) armoured plasma-facing components. In particular, the heat-removal capability of these mock-ups manufactured by European companies with all the main features of the ITER divertor design was investigated both after manufacturing and after thermal cycling up to 20 MW m - 2. Compliance with ITER requirements was explored in terms of bonding quality, heat flux performances and operational compatibility. The main results show an overall good heat-removal capability after the manufacturing process independent of the armour-to-heat sink bonding technology and promising behaviour with respect to thermal fatigue lifetime under heat flux up to 20 MW m - 2 for the CFC-armoured tiles and 15 MW m - 2 for the W-armoured tiles, respectively.

  11. THERMAL HYDRAULIC ANALYSIS OF FIRE DIVERTOR

    International Nuclear Information System (INIS)

    C.B. bAXI; M.A. ULRICKSON; D.E. DRIMEYER; P. HEITZENROEDER

    2000-01-01

    The Fusion Ignition Research Experiment (FIRE) is being designed as a next step in the US magnetic fusion program. The FIRE tokamak has a major radius of 2 m, a minor radius of 0.525 m, and liquid nitrogen cooled copper coils. The aim is to produce a pulse length of 20 s with a plasma current of 6.6 MA and with alpha dominated heating. The outer divertor and baffle of FIRE are water cooled. The worst thermal condition for the outer divertor and baffle is the baseline D-T operating mode (10 T, 6.6 MA, 20 s) with a plasma exhaust power of 67 MW and a peak heat flux of 20 MW/m 2 . A swirl tape (ST) heat transfer enhancement method is used in the outer divertor cooling channels to increase the heat transfer coefficient and the critical heat flux (CHF). The plasma-facing surface consists of tungsten brush. The finite element (FE) analysis shows that for an inlet water temperature of 30 C, inlet pressure of 1.5 MPa and a flow velocity of 10 m/s, the incident critical heat flux is greater than 30 MW/m 2 . The peak copper temperature is 490 C, peak tungsten temperature is 1560 C, and the pressure drop is less than 0.5 MPa. All these results fulfill the design requirements

  12. Multi-fluid modeling of low-recycling divertor regimes

    International Nuclear Information System (INIS)

    Smirnov, R.D.; Pigarov, A.Yu.; Krasheninnikov, S.I.; Rognlien, T.D.; Soukhanovskii, V.A.; Rensink, M.E.; Maingi, R.; Skinner, C.H.; Stotler, D.P.; Bell, R.E.; Kugel, H.W.

    2010-01-01

    The low-recycling regimes of divertor operation in a single-null NSTX magnetic configuration are studied using computer simulations with the edge plasma transport code UEDGE. The edge plasma transport properties pertinent to the low-recycling regimes are demonstrated. These include the flux-limited character of the parallel heat transport and the high plasma temperatures with the flattened profiles in the scrape-off-layer. It is shown that to maintain the balance of particle fluxes at the core interface the deuterium gas puffing rate should increase as the divertor recycling coefficient decreases. The radial profiles of the heat load to the outer divertor plate, the upstream radial plasma profiles, and the effects of the cross-field plasma transport in the low-recycling regimes are discussed. It is also shown that recycling of lithium impurities evaporating from the divertor plate at high surface temperatures can reverse the low-recycling divertor operational regime to the high-recycling one and may cause thermal instability of the divertor plate (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  13. Divertor erosion in DIII-D

    International Nuclear Information System (INIS)

    Whyte, D.G.; Bastasz, R.; Wampler, W.R.; Brooks, J.N.; West, W.P.; Wong, C.P.C.

    1998-05-01

    Net erosion rates of carbon target plates have been measured in situ for the DIII-D lower divertor. The principal method of obtaining this data is the DiMES sample probe. Recent experiments have focused on erosion at the outer strike-point of two divertor plasma conditions: (1) attached (Te > 40 eV) ELMing plasmas and (2) detached (Te 10 cm/year, even with incident heat flux 2 . In this case, measurements and modeling agree for both gross and net carbon erosion, showing the near-surface transport and redeposition of the carbon is well understood and that effective sputtering yields are > 10%. In ELM-free discharges, this erosion rate can account for the rate of carbon accumulation in the core plasma. Divertor plasma detachment eliminates physical sputtering, while spectroscopically measured chemical erosion yields are also found to be low (Y(C/D + ) ≤ 2.0 x 10 -3 ). This leads to suppression of net erosion at the outer strike-point, which becomes a region of net redeposition (∼ 4 cm/year). The private flux wall is measured to be a region of net redeposition with dense, high neutral pressure, attached divertor plasmas. Leading edges intercepting parallel heat flux (∼ 50 MW/m 2 ) have very high net erosion rates (∼ 10 microm/s) at the OSP of an attached plasma. Leading edge erosion, and subsequent carbon redeposition, caused by tile gaps can account for half of the deuterium codeposition in the DIII-D divertor

  14. EU R and D on divertor components

    International Nuclear Information System (INIS)

    Merola, M.; Daenner, W.; Pick, M.

    2005-01-01

    Since the last SOFT conference held in Helsinki in 2002, substantial progress has been made in the EU R and D on the divertor components. A number of activities have been completed and new ones have been launched. The present paper gives an update of the works carried out by the EU Participating Team in support of the development of the divertor, which is one of the most challenging components of the next-step ITER machine. The following topics are covered: (1) the further development and consolidation of suitable technologies for the production of high heat-flux components, which culminated with the successful manufacturing and testing of a full-scale vertical target prototype; (2) the completion of the post-irradiation testing of divertor mock-ups and samples; (3) the preparation for the hydraulic and assembly tests of a complete set of full-scale divertor components; (4) the on-going R and D on the definition of workable acceptance criteria for the procurement of ITER high heat-flux components; (5) the activities in support of the divertor design

  15. Numerical studies on divertor experiments

    International Nuclear Information System (INIS)

    Ueda, N.; Itoh, K.; Itoh, S.-I.; Tanaka, M.; Hasegawa, M.; Shoji, T.; Sugihara, M.

    1988-04-01

    Numerical analysis on the divertor experiments such as JFT-2M tokamak is made by use of the two-dimensional time-dependent simulation code. The plasma in the scrape-off layer (SOL) and divertor region is solved for the given particle and heat sources from the main plasma, Γ p and Q T . Effect of the direction of the toroidal magnetic field is studied. It is found that the heat flux which is proportional to b vector x ∇T i has influences on the divertor plasmas, but has a small effect on the parameters on the midplane in the framework of the fluid model. Parameter survey on Γ p and Q T is made. The transient response of the SOL/divertor plasma to the sudden change of Γ p and Q T is studied. Time delay in the SOL and divertor region is calculated. (author)

  16. Experimental study of the topological aspect of the ergodic divertor in Tore-supra tokamak; Etude experimentale des aspects topologiques du divertor ergodique de Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Costanzo, L

    2001-10-01

    The control of power deposition onto plasma facing components in tokamaks is a determining factor for future thermonuclear fusion reactors. Plasma surface interaction can be performed using limiters or divertors. The ergodic divertor installed on Tore Supra is an atypical example of a magnetic divertor. It consists in applying a magnetic perturbation which establishes a particular topology of the plasma in contact with the wall (edge plasma). We carried out dedicated experiments in order to study parallel heat flux which strike the divertor neutralizers. This quantitative and qualitative analysis of heat flux as a function of experimental conditions allows to determine the profiles of power deposition along the neutralizers. The influence of plasma electron density, additional heating, impurities and injected gas was established. An experimental study of the sheath heat transmission factor {gamma} was carried out by correlating measurements made with Langmuir probes and infrared imaging. This study gave rise to a major conclusion: for ohmic discharges with deuterium injection and most of the time with helium, it was experimentally confirmed that {gamma}=7 in agreement with classical sheath theory. However, an increase of this factor with additional power has been shown. Detached plasma, which is an attractive regime in order to reduce the power deposition, requires an optimized control. A new measurement of the detachment onset has been developed. It is based on the variation of heat flux onto the plates derived from infrared measurements. A detachment cartography with the determination of a new 2D 'IR' Degree of Detachment was carried out allowing to locate the zone where the detachment starts. We can apply this concept both to other tokamaks such as JET and ITER. A comparison between the axisymmetric divertor and the ergodic divertor is also presented concerning the power deposition in the two configurations. Low heat flux with the ergodic divertor is a

  17. Toroidally symmetric/asymmetric effect on the divertor flux due to neon/nitrogen seeding in LHD

    Directory of Open Access Journals (Sweden)

    H. Tanaka

    2017-08-01

    Full Text Available Toroidal distributions of divertor particle flux during neon (Ne and nitrogen (N2 seeded discharges were investigated in the Large Helical Device (LHD. By using 14 toroidally distributed divertor probe arrays, which were positioned at radially inner side where the divertor flux concentrates in the inward-shifted magnetic axis configuration, it is found that Ne puffing leads to toroidally quasi-uniform reduction of divertor particle fluxes; whereas toroidally localized reductions were observed with N2 puffing. The toroidally asymmetric reduction pattern with N2 puffing is strongly related to the magnetic field structure around the N2 puffing port. Assuming that nitrogen particles do not recycle, EMC3-EIRENE simulation shows similar reduction pattern with the experiment around the N2 puffing port.

  18. Progress of High Heat Flux Component Manufacture and Heat Load Experiments in China

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X.; Lian, Y.; Xu, Z.; Chen, J.; Chen, L.; Wang, Q.; Duan, X., E-mail: xliu@swip.ac.cn [Southwestern Institute of Physics, Chengu (China); Luo, G. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China); Yan, Q. [University of Science and Technology Beijing, Beijing (China)

    2012-09-15

    Full text: High heat flux components for first wall and divertor are the key subassembly of the present fusion experiment apparatus and fusion reactors in the future. It is requested the metallurgical bonding among the plasma facing materials (PFMs), heat sink and support materials. As to PFMs, ITER grade vacuum hot pressed beryllium CN-G01 was developed in China and has been accepted as the reference material of ITER first wall. Additionally pure tungsten and tungsten alloys, as well as chemical vapor deposition (CVD) W coating are being developed for the aims of ITER divertor application and the demand of domestic fusion devices, and significant progress has been achieved. For plasma facing components (PFCs), high heat flux components used for divertor chamber are being studied according to the development program of the fusion experiment reactor of China. Two reference joining techniques of W/Cu mockups for ITER divertor chamber are being developed, one is mono-block structure by pure copper casting of tungsten surface following by hot iso-static press (HIP), and another is flat structure by brazing. The critical acceptance criteria of high heat flux components are their high heat load performance. A 60 kW Electron-beam Material testing Scenario (EMS-60) has been constructed at Southwestern Institute of Physics (SWIP),which adopts an electron beam welding gun with maximum energy of 150 keV and 150 x 150 mm{sup 2} scanning area by maximum frame rate of 30 kHz. Furthermore, an Engineering Mockup testing Scenario (EMS-400) facility with 400 kW electron-beam melting gun is under construction and will be available by the end of this year. After that, China will have the comprehensive capability of high heat load evaluation from PFMs and small-scale mockups to engineering full scale PFCs. A brazed W/CuCrZr mockup with 25 x 25 x 40 mm{sup 3} in dimension was tested at EMS-60. The heating and cooling time are 10 seconds and 15 seconds, respectively. The experiment

  19. Features and Initial Results of the DIII-D Advanced Tokamak Radiative Divertor

    International Nuclear Information System (INIS)

    R.C. O'Neill; A.S. Bozek; M.E. Friend; C.B. Baxi; E.E. Reis; M.A. Mahdavi; D.G. Nilson; S.L. Allen; W.P. West

    1999-01-01

    The Radiative Divertor Program of DIII-D is in its final phase with the installation of the cryopump and baffle structure (Phase 1B Divertor) in the upper inner radius of the DIII-D vacuum vessel at the end of this calendar year. This divertor, in conjunction with the Advanced Divertor and the Phase 1A Divertor, located in the lower and upper outer radius of the DIII-D vacuum vessel respectively, provides pumping for density control of the plasma while minimizing the effects on the core confinement. Each divertor consists of a cryobelium cooling ring and a shielded protective structure. The cryo/helium-cooled pumps of all three diverters exhaust helium from the plasma. The protective shielded structure or baffle structure, in the case of the diverters located at the top of the vacuum vessel, provides baffling of neutral charged particles and minimize the flow of impurities back into the core of the plasma. The baffles, which consist of water-cooled panels that allow for the attachment of tiles of various sizes and shapes, house gas puff systems. The intent of the puffing systems is to inject gas in and around the divertor to minimize the heat flux on specific areas on the divertor and its components. The reduction of the heat flux on the divertor minimizes the impurities that are generated from excess heat on divertor components, specifically tiles. Experiments involving the gas puff systems and the divertor structures have shown the heat flux can be spread over a large area of the divertor, reducing the peak heat flux in specific areas. The three diverters also incorporate a variety of diagnostic tools such as halo current monitors, magnetic probes and thermocouples to monitor certain plasma characteristics as well as determine the effectiveness of the cryopumps and baffle configurations. The diverters were designed to optimize pumping performance and to withstand the electromagnetic loads from both halo currents and toroidal induced currents. Incorporated also

  20. Design, R&D and commissioning of EAST tungsten divertor

    Science.gov (United States)

    Yao, D. M.; Luo, G. N.; Zhou, Z. B.; Cao, L.; Li, Q.; Wang, W. J.; Li, L.; Qin, S. G.; Shi, Y. L.; Liu, G. H.; Li, J. G.

    2016-02-01

    After commissioning in 2005, the EAST superconducting tokamak had been operated with its water cooled divertors for eight campaigns up to 2012, employing graphite as plasma facing material. With increase in heating power over 20 MW in recent years, the heat flux going to the divertors rises rapidly over 10 MW m-2 for steady state operation. To accommodate the rapid increasing heat load in EAST, the bolting graphite tile divertor must be upgraded. An ITER-like tungsten (W) divertor has been designed and developed; and firstly used for the upper divertor of EAST. The EAST upper W divertor is modular structure with 80 modules in total. Eighty sets of W/Cu plasma-facing components (PFC) with each set consisting of an outer vertical target (OVT), an inner vertical target (IVT) and a DOME, are attached to 80 stainless steel cassette bodies (CB) by pins. The monoblock W/Cu-PFCs have been developed for the strike points of both OVT and IVT, and the flat type W/Cu-PFCs for the DOME and the baffle parts of both OVT and IVT, employing so-called hot isostatic pressing (HIP) technology for tungsten to CuCrZr heat sink bonding, and electron beam welding for CuCrZr to CuCrZr and CuCrZr to other material bonding. Both monoblock and flat type PFC mockups passed high heat flux (HHF) testing by means of electron beam facilities. The 80 divertor modules were installed in EAST in 2014 and results of the first commissioning are presented in this paper.

  1. Enhancing the DEMO divertor target by interlayer engineering

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, T.R., E-mail: tom.barrett@ccfe.ac.uk [CCFE, Culham Science Centre, Oxfordshire OX14 3DB (United Kingdom); McIntosh, S.C.; Fursdon, M.; Hancock, D.; Timmis, W.; Coleman, M. [CCFE, Culham Science Centre, Oxfordshire OX14 3DB (United Kingdom); Rieth, M.; Reiser, J. [Karlsruhe Institute for Technology, IMF-I, D-7602 Karlsruhe (Germany)

    2015-10-15

    Highlights: • The European ‘near-term’ DEMO forsees a water-cooled divertor. • Divertor targets typically use an interlayer between the armour and structure. • Engineering the properties of the interlayer can yield large gains in performance. • A response surface based design search and optimisation method is used. • A new design passes linear-elastic code rules up to applied heat flux of 18 MW/m{sup 2}. - Abstract: A robust water-cooled divertor target plate solution for DEMO has to date remained elusive. Common to all contemporary concepts is an interlayer at the boundary between the tungsten armour and the cooling structure. In this paper we show by design optimisation that an effectively designed interlayer can produce dramatic gains in power handling. By engineering the interlayer as part of the design study, it is found that divertor performance is enhanced by either a low conductivity ‘Thermal Break’ interlayer or an ‘Ultra-Compliant’ interlayer. For a 10 MW/m{sup 2} surface heat flux we find that a thermal conductivity of 15 W/mK and elastic modulus of 1 GPa are effective. A design is proposed which passes linear-elastic code rules up to an applied heat flux of 18 MW/m{sup 2}.

  2. Enhancing the DEMO divertor target by interlayer engineering

    International Nuclear Information System (INIS)

    Barrett, T.R.; McIntosh, S.C.; Fursdon, M.; Hancock, D.; Timmis, W.; Coleman, M.; Rieth, M.; Reiser, J.

    2015-01-01

    Highlights: • The European ‘near-term’ DEMO forsees a water-cooled divertor. • Divertor targets typically use an interlayer between the armour and structure. • Engineering the properties of the interlayer can yield large gains in performance. • A response surface based design search and optimisation method is used. • A new design passes linear-elastic code rules up to applied heat flux of 18 MW/m"2. - Abstract: A robust water-cooled divertor target plate solution for DEMO has to date remained elusive. Common to all contemporary concepts is an interlayer at the boundary between the tungsten armour and the cooling structure. In this paper we show by design optimisation that an effectively designed interlayer can produce dramatic gains in power handling. By engineering the interlayer as part of the design study, it is found that divertor performance is enhanced by either a low conductivity ‘Thermal Break’ interlayer or an ‘Ultra-Compliant’ interlayer. For a 10 MW/m"2 surface heat flux we find that a thermal conductivity of 15 W/mK and elastic modulus of 1 GPa are effective. A design is proposed which passes linear-elastic code rules up to an applied heat flux of 18 MW/m"2.

  3. Divertor conceptual designs for a fusion power plant

    International Nuclear Information System (INIS)

    Norajitra, P.; Ihli, T.; Janeschitz, G.; Abdel-Khalik, S.; Mazul, I.; Malang, S.

    2007-01-01

    The development of a divertor concept for post-ITER fusion power plants is deemed to be an urgent task to meet the EU Fast Track scenario. Developing a divertor is particularly challenging due to the wide range of requirements to be met including the high incident peak heat flux, the blanket design with which the divertor has to be integrated, sputtering erosion of the plasma-facing material caused by the incident a particles, radiation effects on the properties of structural materials, and efficient recovery and conversion of the divertor thermal power (∝15% of the total fusion thermal power) by maximizing the coolant operating temperature while minimizing the pumping power. In the course of the EU PPCS, three near-term (A, B and AB) and two advanced power plant models (C, D) were investigated. Model A utilizes a water-cooled lead-lithium (WCLL) blanket and a water-cooled divertor with a peak heat flux of 15 MW/m 2 . Model B uses a He-cooled ceramics/beryllium pebble bed (HCPB) blanket and a He-cooled divertor concept (10 MW/m 2 ). Model AB uses a He-cooled lithium-lead (HCLL) blanket and a He-cooled divertor concept (10 MW/m 2 ). Model C is based on a dual-coolant (DC) blanket (lead/lithium self-cooled bulk and He-cooled structures) and a He-cooled divertor (10 MW/m 2 ). Model D employs a self-cooled lead/lithium (SCLL) blanket and lead-lithiumcooled divertor (5 MW/m 2 ). The values in parenthesis correspond to the maximum peak heat fluxes required. It can be noted that the helium-cooled divertor is used in most of the EU plant models; it has also been proposed for the US ARIES-CS reactor study. Since 2002, it has been investigated extensively in Europe under the PPCS with the goal of reaching a maximum heat flux of at least 10 MW/m2. Work has covered many areas including conceptual design, analysis, material and fabrication issues, and experiments. Generally, the helium-cooled divertor is considered to be a suitable solution for fusion power plants, as it

  4. Lithium droplet divertor collector for ions and heat

    International Nuclear Information System (INIS)

    Wells, W.M.

    1979-01-01

    Coping with the ion and energy fluxes which must be collected with a tokamak divertor is one of the more difficult technological challenges for a power producing reactor. Use of stationary solid surfaces to collect ions and the attendant heat flux faces technology feasibility questions. Calculations indicate that gravity-driven flow of liquid metals having a free surface will not move adequately fast. It is proposed to circumvent these problems by having high velocity lithium droplets perform the collection functions. Droplets which are not in contact with a wall encounter only very small retardation effects in a magnetic field, and these droplets can be formed by nozzles outside of the magnetic field. If they travel at about 150 m/s, they can absorb in excess of 1 kW/cm 2 of projected area. The hydrogen isotope ion fluence is well below the saturation dose which has been achieved with lithium

  5. Radiative divertor plasmas with convection in DIII-D

    International Nuclear Information System (INIS)

    Leonard, A.W.; Porter, G.D.; Wood, R.D.; Allen, S.L.; Boedo, J.; Brooks, N.H.; Evans, T.E.; Fenstermacher, M.E.; Hill, D.N.; Isler, R.C.; Lasnier, C.J.; Lehmer, R.D.; Mahdavi, M.A.; Maingi, R.; Moyer, R.A.; Petrie, T.W.; Schaffer, M.J.; Wade, M.R.; Watkins, J.G.; West, W.P.; Whyte, D.G.

    1998-01-01

    The radiation of divertor heat flux on DIII-D [J. Luxon et al., in Proceedings of the 11th International Conference on Plasma Physics and Controlled Nuclear Fusion (International Atomic Energy Agency, Vienna, 1987), p. 159] is shown to greatly exceed the limits imposed by assumptions of energy transport dominated by electron thermal conduction parallel to the magnetic field. Approximately 90% of the power flowing into the divertor is dissipated through low-Z radiation and plasma recombination. The dissipation is made possible by an extended region of low electron temperature in the divertor. A one-dimensional analysis of the parallel heat flux finds that the electron temperature profile is incompatible with conduction-dominated parallel transport. Plasma flow at up to the ion acoustic speed, produced by upstream ionization, can account for the parallel heat flux. Modeling with the two-dimensional fluid code UEDGE [T. Rognlien, J. L. Milovich, M. E. Rensink, and G. D. Porter, J. Nucl. Mater. 196 endash 198, 347 (1992)] has reproduced many of the observed experimental features. copyright 1998 American Institute of Physics

  6. Technology R&D Activities for the ITER Full-tungsten Divertor

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzetto, P.; Bednarek, M.; Gavila, P.; Riccardi, B.; Saibene, G., E-mail: patrick.lorenzetto@f4e.europa.eu [Fusion for Energy, Barcelona (Spain); Escourbiac, F.; Hirai, T.; Merola, M.; Pitts, R. [ITER Organization, St Paul-lez-Durance (France); Suzuki, S. [JAEA, Ibaraki (Japan); Mazul, I. [Efremov Institute, St.Petersburg (Russian Federation)

    2012-09-15

    Full text: The current ITER Baseline foresees the use of carbon fibre composite (CFC) as armour material in the high heat flux strike point regions and tungsten (W) elsewhere in the divertor for the initial non-active phase of operation with hydrogen and helium plasmas. This divertor would then be replaced with a full-W divertor for the nuclear phase with deuterium and deuterium- tritium plasmas. To reduce costs the ITER Organization (IO) has proposed to install a full-W divertor from start of operations and to implement a work programme to develop a full-W divertor design, qualify the corresponding fabrication technology and investigate critical physics and operational issues with support from the R&D fusion community. An extensive R&D programme has been implemented over more than 15 years to develop fabrication technologies for the procurement of ITER divertor components. Significant effort has been devoted to the development of reliable armour/heat sink joining techniques such as Hot Isostatic Pressing (Europe), Hot Radial Pressing (Europe) or brazing (Japan, Russia). In this development programme, established for the CFC/W divertor variant, the design solution for W-armoured components was optimized for the divertor baffle and dome regions, namely for steady state operation conditions at heat flux values of typically 5 MW/m{sup 2} and for slow transient events at heat flux values up to 10 MW/m{sup 2}. A very positive outcome of this R&D work has been that some fabrication technologies mentioned above can achieve much higher performances, close to the expected slow transient conditions for the strike point region (20 MW/m{sup 2} for 10 s). To prepare for the procurement of a full-W divertor, a development work programme has been launched including in particular the manufacturing and high heat flux testing of small-scale mock-ups with improved monoblock geometries and full-W pre-qualification prototypes, and the manufacturing and testing of qualification full

  7. A Lithium Vapor Box Divertor Similarity Experiment

    Science.gov (United States)

    Cohen, Robert A.; Emdee, Eric D.; Goldston, Robert J.; Jaworski, Michael A.; Schwartz, Jacob A.

    2017-10-01

    A lithium vapor box divertor offers an alternate means of managing the extreme power density of divertor plasmas by leveraging gaseous lithium to volumetrically extract power. The vapor box divertor is a baffled slot with liquid lithium coated walls held at temperatures which increase toward the divertor floor. The resulting vapor pressure differential drives gaseous lithium from hotter chambers into cooler ones, where the lithium condenses and returns. A similarity experiment was devised to investigate the advantages offered by a vapor box divertor design. We discuss the design, construction, and early findings of the vapor box divertor experiment including vapor can construction, power transfer calculations, joint integrity tests, and thermocouple data logging. Heat redistribution of an incident plasma-based heat flux from a typical linear plasma device is also presented. This work supported by DOE Contract No. DE-AC02-09CH11466 and The Princeton Environmental Institute.

  8. Infrared Camera Diagnostic for Heat Flux Measurements on NSTX

    International Nuclear Information System (INIS)

    D. Mastrovito; R. Maingi; H.W. Kugel; A.L. Roquemore

    2003-01-01

    An infrared imaging system has been installed on NSTX (National Spherical Torus Experiment) at the Princeton Plasma Physics Laboratory to measure the surface temperatures on the lower divertor and center stack. The imaging system is based on an Indigo Alpha 160 x 128 microbolometer camera with 12 bits/pixel operating in the 7-13 (micro)m range with a 30 Hz frame rate and a dynamic temperature range of 0-700 degrees C. From these data and knowledge of graphite thermal properties, the heat flux is derived with a classic one-dimensional conduction model. Preliminary results of heat flux scaling are reported

  9. Effect of asymmetric plasma potential in the SOL on the particle radial transport and heat flux broadening

    International Nuclear Information System (INIS)

    Hara, Junichiro; Uesugi, Yoshihiko; Miura, Yukitoshi; Kawashima, Hisato.

    1997-01-01

    The effective divertor heat-load relaxation using ExB induced convective cells in the SOL is studied. The ExB convective cells in the SOL are generated by the toroidally asymmetric divertor biasing, which can control the local plasma potential in the SOL. The preliminary experiment has been done in the JFT-2M tokamak with poloidal divertor. The helical SOL current flows along the magnetic field between the locally biased inboard plate and grounded outer plates, thereby modifying plasma potential in the vicinity of the local divertor current flow. The generation of the poloidal electric field reaching up to 1.5kV/m locally in the SOL and the modification of the heat flux profile on the divertor plate is observed. (author)

  10. Numerical evaluation of heat flux and surface temperature on a misaligned JET divertor W lamella during ELMs

    Czech Academy of Sciences Publication Activity Database

    Dejarnac, Renaud; Podolník, Aleš; Komm, Michael; Arnoux, G.; Coenen, J.W.; Devaux, S.; Frassinetti, L.; Gunn, J. P.; Matthews, G. F.; Pitts, R.A.

    2014-01-01

    Roč. 54, č. 12 (2014), s. 123011-123011 ISSN 0029-5515 Institutional support: RVO:61389021 Keywords : PIC simulations * power flux * plasma–wall interactions * JET * divertor Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 3.062, year: 2014 http://iopscience.iop.org/0029-5515/54/12/123011/pdf/0029-5515_54_12_123011.pdf

  11. A solid tungsten divertor for ASDEX Upgrade

    International Nuclear Information System (INIS)

    Herrmann, A; Greuner, H; Jaksic, N; Böswirth, B; Maier, H; Neu, R; Vorbrugg, S

    2011-01-01

    The conceptual design of a solid tungsten divertor for ASDEX Upgrade (AUG) is presented. The Div-III design is compatible with the existing divertor structure. It re-establishes the energy and heat receiving capability of a graphite divertor and overcomes the limitations of tungsten coatings. In addition, a solid tungsten divertor allows us to investigate erosion and bulk deuterium retention as well as test castellation and target tilting. The design criteria as well as calculations of forces due to halo and eddy currents are presented. The thermal properties of the proposed sandwich structure are calculated with finite element method models. After extensive testing of a target tile in the high heat flux test facility GLADIS, two solid tungsten tiles were installed in AUG for in-situ testing.

  12. High heat flux tests at divertor relevant conditions on water-cooled swirl tube targets

    International Nuclear Information System (INIS)

    Schlosser, J.; Boscary, J.

    1994-01-01

    High heat flux experiments were performed to provide a technology for heat flux removal under NET/ITER relevant conditions. The water-cooled rectangular test sections were made of hardened copper with a stainless steel twisted tape installed inside a circular channel and one-side heated. The tests aimed to investigate the heat transfer and the critical heat flux in the subcooled boiling regime. A CHF data base of 63 values was established. Test results have shown the thermalhydraulic ability of swirl tubes to sustain an incident heat flux up to a 30 MW.m -2 range. (author) 10 refs.; 7 figs

  13. Divertor design for the Tokamak Physics Experiment

    International Nuclear Information System (INIS)

    Hill, D.N.; Braams, B.

    1994-05-01

    In this paper we discuss the present divertor design for the planned TPX tokamak, which will explore the physics and technology of steady-state (1000s pulses) heat and particle removal in high confinement (2--4x L-mode), high beta (β N ≥ 3) divertor plasmas sustained by non-inductive current drive. The TPX device will operate in the double-null divertor configuration, with actively cooled graphite targets forming a deep (0.5 m) slot at the outer strike point. The peak heat flux on, the highly tilted (74 degrees from normal) re-entrant (to recycle ions back toward the separatrix) will be in the range of 4--6 MW/m 2 with 18 MW of neutral beams and RF heating power. The combination of active pumping and gas puffing (deuterium plus impurities), along with higher heating power (45 MW maximum) will allow testing of radiative divertor concepts at ITER-like power densities

  14. In-pile thermocycling testing and post-test analysis of beryllium divertor mockups

    Energy Technology Data Exchange (ETDEWEB)

    Giniatulin, R.; Mazul, I. [Efremov Inst., St. Petersburg (Russian Federation); Melder, R.; Pokrovsky, A.; Sandakov, V.; Shiuchkin, A.

    1998-01-01

    The main damaging factors which impact the ITER divertor components are neutron irradiation, cyclic surface heat loads and hydrogen environment. One of the important questions in divertor mockups development is the reliability of beryllium/copper joints and the beryllium resistance under neutron irradiation and thermal cycling. This work presents the experiment, where neutron irradiation and thermocyclic heat loads were applied simultaneously for two beryllium/copper divertor mockups in a nuclear reactor channel to simulate divertor operational conditions. Two mockups with different beryllium grades were mounted facing each other with the tantalum heater placed between them. This device was installed in the active zone of the nuclear reactor SM-2 (Dimitrovgrad, Russia) and the tantalum block was heated by neutron irradiation up to a high temperature. The main part of the heat flux from the tantalum surface was transported to the beryllium surface through hydrogen, as a result the heat flux loaded two mockups simultaneously. The mockups were cooled by reactor water. The device was lowered to the active zone so as to obtain the heating regime and to provide cooling lifted. This experiment was performed under the following conditions: tantalum heater temperature - 1950degC; hydrogen environment -1000 Pa; surface heat flux density -3.2 MW/m{sup 2}; number of thermal cycles (lowering and lifting) -101; load time in each cycle - 200-5000 s; dwell time (no heat flux, no neutrons) - 300-2000 s; cooling water parameters: v - 1 m/s, Tin - 50degC, Pin - 5 MPa; neutron fluence -2.5 x 10{sup 20} cm{sup -2} ({approx}8 years of ITER divertor operation from the start up). The metallographic analysis was performed after experiment to investigate the beryllium and beryllium/copper joint structures, the results are presented in the paper. (author)

  15. On the use of flat tile armour in high heat flux components

    Science.gov (United States)

    Merola, M.; Vieider, G.

    1998-10-01

    The possibility to have a flat tile geometry for those high heat flux components subjected to a convective heat flux (namely the divertor dump target, lower vertical target, and the limiter) has been investigated. Because of the glancing incidence of the power load, if an armour tile falls off an extremely high heat flux hits the leading edge of the adjacent tile. As a result a rapid temperature increase occurs in the armour-heat sink joint. The heat flux to the water coolant also increases rapidly up to a factor of 1.7 and 2.3 for a beryllium and CFC armour, respectively, thus causing possible critical heat flux problems. Thermal stresses in the armour-heat sink joint double in less than 0.4 s and triplicate after 1 s thus leading to a possible cascade failure. Therefore the use of a flat tile geometry for these components does not seem to be appropriate. In this case a monoblock geometry gives a much more robust solution.

  16. On the use of flat tile armour in high heat flux components

    International Nuclear Information System (INIS)

    Merola, M.; Vieider, G.

    1998-01-01

    The possibility to have a flat tile geometry for those high heat flux components subjected to a convective heat flux (namely the divertor dump target, lower vertical target, and the limiter) has been investigated. Because of the glancing incidence of the power load, if an armour tile falls off an extremely high heat flux hits the leading edge of the adjacent tile. As a result a rapid temperature increase occurs in the armour-heat sink joint. The heat flux to the water coolant also increases rapidly up to a factor of 1.7 and 2.3 for a beryllium and CFC armour, respectively, thus causing possible critical heat flux problems. Thermal stresses in the armour-heat sink joint double in less than 0.4 s and triplicate after 1 s thus leading to a possible cascade failure. Therefore the use of a flat tile geometry for these components does not seem to be appropriate. In this case a monoblock geometry gives a much more robust solution. (orig.)

  17. Modeling of divertor particle and heat loads during application of resonant magnetic perturbation fields for ELM control in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, O., E-mail: o.schmitz@fz-juelich.de [Forschungszentrum Jülich, IEK-4, Association EURATOM-FZJ, Jülich (Germany); Becoulet, M. [CEA/IRFM, Cadarache, 13108 St. Paul-lez-Durance Cedex (France); Cahyna, P. [IPP AS CR, Za Slovankou 3, 18200 Prague 8 (Czech Republic); Evans, T.E. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Feng, Y. [Max-Planck-Institut für Plasmaphysik, Greifswald (Germany); Frerichs, H.; Kirschner, A. [Forschungszentrum Jülich, IEK-4, Association EURATOM-FZJ, Jülich (Germany); Kukushkin, A. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Laengner, R. [Forschungszentrum Jülich, IEK-4, Association EURATOM-FZJ, Jülich (Germany); Lunt, T. [Max-Planck-Institut für Plasmaphysik, Greifswald (Germany); Loarte, A.; Pitts, R. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Reiser, D.; Reiter, D. [Forschungszentrum Jülich, IEK-4, Association EURATOM-FZJ, Jülich (Germany); Saibene, G. [Fusion for Energy Joint Undertaking, Barcelona (Spain); Samm, U. [Forschungszentrum Jülich, IEK-4, Association EURATOM-FZJ, Jülich (Germany)

    2013-07-15

    First results from three-dimensional modeling of the divertor heat and particle flux pattern during application of resonant magnetic perturbation fields as ELM control scheme in ITER with the EMC3-Eirene fluid plasma and kinetic neutral transport code are discussed. The formation of a helical magnetic footprint breaks the toroidal symmetry of the heat and particle fluxes. Expansion of the flux pattern as far as 60 cm away from the unperturbed strike line is seen with vacuum RMP fields, resulting in a preferable heat flux spreading. Inclusion of plasma response reduces the radial extension of the heat and particle fluxes and results in a heat flux peaking closer to the unperturbed level. A strong reduction of the particle confinement is found. 3D flow channels are identified as a consistent reason due to direct parallel outflow from inside of the separatrix. Their radial inward expansion and hence the level of particle pump out is shown to be dependent on the perturbation level.

  18. Plasma flow in the DIII-D divertor

    International Nuclear Information System (INIS)

    Boedo, J.A.; Porter, G.D.; Schaffer, M.J.

    1998-07-01

    Indications that flows in the divertor can exhibit complex behavior have been obtained from 2-D modeling but so far remain mostly unconfirmed by experiment. An important feature of flow physics is that of flow reversal. Flow reversal has been predicted analytically and it is expected when the ionization source arising from neutral or impurity ionization in the divertor region is large, creating a high pressure zone. Plasma flows arise to equilibrate the pressure. A radiative divertor regime has been proposed in order to reduce the heat and particle fluxes to the divertor target plates. In this regime, the energy and momentum of the plasma are dissipated into neutral gas introduced in the divertor region, cooling the plasma by collisional, radiative and other atomic processes so that the plasma becomes detached from the target plates. These regimes have been the subject of extensive studies in DIII-D to evaluate their energy and particle transport properties, but only recently it has been proposed that the energy transport over large regions of the divertor must be dominated by convection instead of conduction. It is therefore important to understand the role of the plasma conditions and geometry on determining the region of convection-dominated plasma in order to properly control the heat and particle fluxes to the target plates and hence, divertor performance. The authors have observed complex structures in the deuterium ion flows in the DIII-D divertor. Features observed include reverse flow, convective flow over a large volume of the divertor and stagnant flow. They have measured large gradients in the plasma potential across the separatrix in the divertor and determined that these gradients induce poloidal flows that can potentially affect the particle balance in the divertor

  19. Experiences with tungsten coatings in high heat flux tests and under plasma load in ASDEX Upgrade

    International Nuclear Information System (INIS)

    Herrmann, A; Greuner, H; Fuchs, J C; Marne, P de; Neu, R

    2009-01-01

    ASDEX Upgrade was operated with about 6400 s plasma discharge during the scientific program in 2007/2008 exploring tungsten as a first wall material in tokamaks. In the first phase, the heating power was restricted to 10 MW. It was increased to 15 MW in the second phase. During this operational period, a delamination of the 200 μm W-VPS coating happened at 2 out of 128 tiles of the outer divertor and an unscheduled opening was required. In the third phase, ASDEX Upgrade was operated with partly predamaged tiles and up to 15 MW heating power. The target load was actively controlled by N 2 -seeding. This paper presents the screening test of target tiles in the high heat flux test facility GLADIS, experiences with operation and detected damages of the outer divertor as well as the heat load to the outer divertor and the reasons for the toroidal asymmetry of the divertor load.

  20. Experimental studies of the snowflake divertor in TCV

    Directory of Open Access Journals (Sweden)

    B. Labit

    2017-08-01

    Full Text Available To address the risk that, in a fusion reactor, the conventional single-null divertor (SND configuration may not be able to handle the power exhaust, alternative divertor configurations, such as the Snowflake divertor (SFD, are investigated in TCV. The expected benefits of the SFD-minus in terms of power load and peak heat flux are discussed and compared to experimental measurements. In addition, key results obtained during the last years are summarized.

  1. Comparison between FEM and high heat flux thermal fatigue testing results of ITER divertor plasma facing mock-ups

    Energy Technology Data Exchange (ETDEWEB)

    Crescenzi, F., E-mail: fabio.crescenzi@enea.it; Roccella, S.; Visca, E.; Moriani, A.

    2014-10-15

    Highlights: • Divertor is an important part of the ITER machine. • Finite element analysis allows designers to explore multiple design options, reducing physical prototypes and optimizing design performance. • The hydraulic thermal-mechanical analysis performed by ANSYS and the test results on small-scale mock-ups manufactured by HRP were compared. • FEA results confirmed many experimental data, then it could be very useful for next design optimization. - Abstract: The divertor is one of the most challenging components of “DEMO” the next step ITER machine, so many tasks regarding modeling and experiments have been made in the past years to assess manufacturing processes, materials and thus the life-time of the components. In this context the finite element analysis (FEA) allows designers to explore multiple design options, to reduce physical prototypes and to optimize design performance. The comparison between the hydraulic thermal-mechanical analysis performed by ANSYS WORKBENCH 14.5 and the test results [1] on small-scale mock-ups manufactured with the Hot Radial Pressing (HRP) [2] technology is presented in this paper. During the thermal fatigue testing in the Efremov TSEFEY facility to assess the heat flux load-carrying capability of the mock-ups, only the surface temperature was measured, so the FEA was important because it allowed to know any other information (temperature inside the materials, local water temperature, local stress, etc.). FEA was performed coupling the thermal-hydraulic analysis, that calculated the temperature distributions on the components and the heat transfer coefficient (HTC) between water and heat sink tube, with the mechanical analysis. The comparison between analysis and testing results was based on the temperature maps of the loaded surface and on number of the cycles supported during the testing and those predicted by the mechanical analysis using the experimental fatigue curves for CuCrZr-IG, that is the structural

  2. A new scaling for divertor detachment

    Science.gov (United States)

    Goldston, R. J.; Reinke, M. L.; Schwartz, J. A.

    2017-05-01

    The ITER design, and future reactor designs, depend on divertor ‘detachment,’ whether partial, pronounced or complete, to limit heat flux to plasma-facing components and to limit surface erosion due to sputtering. It would be valuable to have a measure of the difficulty of achieving detachment as a function of machine parameters, such as input power, magnetic field, major radius, etc. Frequently the parallel heat flux, estimated typically as proportional to P sep/R or P sep B/R, is used as a proxy for this difficulty. Here we argue that impurity cooling is dependent on the upstream density, which itself must be limited by a Greenwald-like scaling. Taking this into account self-consistently, we find the impurity fraction required for detachment scales dominantly as power divided by poloidal magnetic field. The absence of any explicit scaling with machine size is concerning, as P sep surely must increase greatly for an economic fusion system, while increases in the poloidal field strength are limited by coil technology and plasma physics. This result should be challenged by comparison with 2D divertor codes and with measurements on existing experiments. Nonetheless, it suggests that higher magnetic field, stronger shaping, double-null operation, ‘advanced’ divertor configurations, as well as alternate means to handle heat flux such as metallic liquid and/or vapor targets merit greater attention.

  3. Divertor plasma studies on DIII-D: Experiment and modeling

    International Nuclear Information System (INIS)

    West, W.P.; Brooks, N.H.; Allen, S.L.

    1996-09-01

    In a magnetically diverted tokamak, the scrape-off layer (SOL) and divertor plasma provides separation between the first wall and the core plasma, intercepting impurities generated at the wall before they reach the core plasma. The divertor plasma can also serve to spread the heat and particle flux over a large area of divertor structure wall using impurity radiation and neutral charge exchange, thus reducing peak heat and particle fluxes at the divertor strike plate. Such a reduction will be required in the next generation of tokamaks, for without it, the divertor engineering requirements are very demanding. To successfully demonstrate a radiative divertor, a highly radiative condition with significant volume recombination must be achieved in the divertor, while maintaining a low impurity content in the core plasma. Divertor plasma properties are determined by a complex interaction of classical parallel transport, anomalous perpendicular transport, impurity transport and radiation, and plasma wall interaction. In this paper the authors describe a set of experiments on DIII-D designed to provide detailed two dimensional documentation of the divertor and SOL plasma. Measurements have been made in operating modes where the plasma is attached to the divertor strike plate and in highly radiating cases where the plasma is detached from the divertor strike plate. They also discuss the results of experiments designed to influence the distribution of impurities in the plasma using enhanced SOL plasma flow. Extensive modeling efforts will be described which are successfully reproducing attached plasma conditions and are helping to elucidate the important plasma and atomic physics involved in the detachment process

  4. Development of a compact W-shaped pumped divertor in JT-60U

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, S.; Hosogane, N.; Masaki, K.; Kodama, K.; Sasajima, T.; Kishiya, K.; Takahashi, S.; Shimizu, K.; Akino, N.; Miyo, Y.; Hiratsuka, H.; Saidoh, M. [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Inoue, M.; Umakoshi, T.; Onozuka, M.; Morimoto, M. [Mitsubishi Heavy Industries, Wadasaki-cho, Hyogo-ku, Kobe-shi, 642 (Japan)

    1998-09-01

    In JT-60U, the modification to a W-shaped pumped divertor will be completed in May 1997, aiming to realize sufficient reduction in heat flux to the targets and good H-mode confinement simultaneously. W-shaped geometry is optimized not only for forming radiative divertor plasmas and reducing the back flow of neutral particles but also for allowing various experimental configurations. Toroidally and poloidally segmented divertor plates, dome and baffles are arranged in a W-shaped poloidal configuration. The pumping speed can be changed during a shot by variable shutter valves in the three pumping ports under the outer baffle. The net throughput is enough for particle control in the steady radiative operations with high power NBI heating. Carbon fiber composite (CFC) tiles are used for the divertor targets and the divertor throat where large heat flux is expected. Gaps between two adjacent segments are carefully sealed to suppress the leak of neutral gas from the exhaust duct below the divertor and baffles. The strength of the whole structure is confirmed by an electromagnetic force analysis and structural analysis carried out for disruptions of 3 MA discharges with a halo current. (orig.) 11 refs.

  5. Design, fabrication, and testing of a helium-cooled module for the ITER divertor

    International Nuclear Information System (INIS)

    Baxi, C.B.; Smith, J.P.; Youchison, D.

    1994-08-01

    The International Thermonuclear Reactor (ITER) will have a single-null divertor with total power flow of 200 MW and a peak heat flux of about 5 MW/m 2 . The reference coolant for the divertor is water. However, helium is a viable alternative and offers advantages from safety considerations, such as excellent radiation stability and chemical inertness. In order to prove the feasibility of helium cooling at ITER relevant heat flux conditions, General Atomics designed, fabricated, and tested a helium-cooled divertor module. The module was made from dispersion strengthened copper, with a heat flux surface 25 mm wide and 80 mm long, designed for twice the ITER divertor heat flux. Different techniques were examined to enhance the heat transfer, which in turn reduced the flow and pumping power required to cool the module. It was concluded that an extended surface was the most practical solution. An optimization study was performed to find the best extended surface parameters. The optimum extended surface geometry consisted of fins: 10 mm high, 0.4 mm thick with a 1 mm pitch. It was estimated to require a pumping power of 150 W to remove 20 kW of power. This is more than an order of magnitude reduction in pumping power requirement, compared to smooth surface. The module was fabricated by electric discharge machining (EDM) process. The testing was carried out at SNLA during August 1993. The testing confirmed the design calculations. The peak heat flux during the test was 10 MW/m 2 applied over a surface area of 20 cm 2 . The pumping power calculated from flow rate and pressure drop measurement was about 160 W, which was less than 1% of the power removed. It is planned to test the module to higher temperature limits and higher heat fluxes during coming months. As a result of this effort we conclude that helium cooling of the ITER divertor is feasible without requiring a very large helium pressure or a large pumping power

  6. Energy and particle transport in the radiative divertor plasmas of DIII-D

    International Nuclear Information System (INIS)

    Leonard, A.W.; Allen, S.L.; Brooks, N.H.

    1997-06-01

    It has been argued that divertor energy transport dominated by parallel electron thermal conduction, or q parallel = -kT 5/2 2 dT e /ds parallel, leads to severe localization of the intense radiating region and ultimately limits the fraction of energy flux that can be radiated before striking the divertor target. This is due to the strong T 5/2 e dependence of electron heat conduction which results in very short spatial scales of the T e gradient at high power densities and low temperatures where deuterium and impurities radiate most effectively. However, we have greatly exceeded this constraint on DIII-D with deuterium gas puffing which reduces the peak heat flux to the divertor plate a factor of 5 while distributing the divertor radiation over a long length

  7. The ITER divertor cassette project

    International Nuclear Information System (INIS)

    Ulrickson, M.; Tivey, R.; Akiba, M.

    2001-01-01

    The divertor ''Large Project'' was conceived with the aim of demonstrating the feasibility of meeting the lifetime requirements by employing the candidate armor materials of beryllium, tungsten (W) and carbon-fiber-composite (CFC). At the start, there existed only limited experience with constructing water-cooled high heat flux armored components for tokamaks. To this was added the complication posed by the need to use a silver-free joining technique that avoids the transmutation of n-irradiated silver to cadmium. The research project involving the four Home Teams (HTs) has focused on the design, development, manufacture and testing of full-scale Plasma Facing Components (PFCs) suitable for ITER. The task addressed all the issues facing ITER divertor design, such as providing adequate armor erosion lifetime, meeting the required armor-heat sink joint lifetime and heat sink fatigue life, sustaining thermal-hydraulic and electromechanical loads, and seeking to identify the most cost-effective manufacturing options. This paper will report the results of the divertor large project. (author)

  8. The ITER divertor cassette project

    International Nuclear Information System (INIS)

    Ulrickson, M.; Tivey, R.; Akiba, M.

    1999-01-01

    The divertor 'Large Project' was conceived with the aim of demonstrating the feasibility of meeting the lifetime requirements by employing the candidate armor materials of beryllium, tungsten (W) and carbon-fiber-composite (CFC). At the start, there existed only limited experience with constructing water-cooled high heat flux armored components for tokamaks. To this was added the complication posed by the need to use a silver-free joining technique that avoids the transmutation of n-irradiated silver to cadmium. The research project involving the four Home Teams (HTs) has focused on the design, development, manufacture and testing of full-scale Plasma Facing Components (PFCs) suitable for ITER. The task addressed all the issues facing ITER divertor design, such as providing adequate armor erosion lifetime, meeting the required armor-heat sink joint lifetime and heat sink fatigue life, sustaining thermal-hydraulic and electromechanical loads, and seeking to identify the most cost-effective manufacturing options. This paper will report the results of the divertor large project. (author)

  9. Analysis of heat transfer and erosion effects on ITER divertor plasma facing components induced by slow high-power transients

    International Nuclear Information System (INIS)

    Federici, G.; Raffray, A.R.; Chiocchio, S.; Esser, B.; Dietz, J.; Igitkhanov, Y.; Janeschitz, G.

    1995-01-01

    This paper presents the results of an analysis carried out to investigate the thermal response of ITER divertor plasma facing components (PFC's) clad with Be, W, and CFC, to high-recycling, high-power thermal transients (i.e. 10--30 MW/m 2 ) which are anticipated to last up to a few seconds. The armour erosion and surface melting are estimated for the different plasma facing materials (PFM's) together with the maximum heat flux to the coolant, and armour/heat-sink interface temperature. The analysis assumes that intense target evaporation will lead to high radiative power losses in the plasma in front of the target which self-protects the target. The cases analyzed clarify the influence of several key parameters such as the plasma heat flux to the target, the loss of the melt layer, the duration of the event, the thickness of the armour, and comparison is made with cases without vapor shielding. Finally, some implications for the performance and lifetime of divertor PFC's clad with different PFM's are discussed

  10. Energy and particle control characteristics of the ASDEX Upgrade 'LYRA' divertor

    International Nuclear Information System (INIS)

    Kaufmann, M.; Bosch, H.S.; Herrmann, A.

    1999-01-01

    In 1997 the new 'LYRA' divertor went into operation at ASDEX Upgrade and the neutral beam heating power was increased to 20 MW by installation of a second injector. This leads to the relatively high value of P/R of 12 MW/m. It has been shown that the ASDEX Upgrade LYRA divertor is capable of handling such high heating powers. Measurements presented in this paper reveal a reduction of the maximum heat flux in the LYRA divertor by more than a factor of two compared to the open Divertor I. This reduction is caused by radiative losses inside the divertor region. Carbon radiation cools the divertor plasma down to a few eV where hydrogen radiation losses become significant. They are increased due to an effective reflection of neutrals into the hot separatrix region. B2-Eirene modelling of the performed experiments supports the experimental findings and refines the understanding of loss processes in the divertor region. (author)

  11. Energy and particle control characteristics of the ASDEX Upgrade 'LYRA' divertor

    International Nuclear Information System (INIS)

    Kaufmann, M.; Bosch, H.-S.; Herrmann, A.

    2001-01-01

    In 1997 the new 'LYRA' divertor went into operation at ASDEX Upgrade and the neutral beam heating power was increased to 20 MW by installation of a second injector. This leads to the relatively high value of P/R of 12 MW/m. It has been shown that the ASDEX Upgrade LYRA divertor is capable of handling such high heating powers. Measurements presented in this paper reveal a reduction of the maximum heat flux in the LYRA divertor by more than a factor of two compared to the open Divertor I. This reduction is caused by radiative losses inside the divertor region. Carbon radiation cools the divertor plasma down to a few eV where hydrogen radiation losses become significant. They are increased due to an effective reflection of neutrals into the hot separatrix region. B2-Eirene modelling of the performed experiments supports the experimental findings and refines the understanding of loss processes in the divertor region. (and others)

  12. Thermomechanical simulation of WEST actively cooled upper divertor

    International Nuclear Information System (INIS)

    Batal, T.; Richou, M.; Guilhem, D.; Firdaouss, M.; Larroque, S.; Ferlay, F.; Missirlian, M.; Bucalossi, J.

    2016-01-01

    The Tore Supra tokamak is being transformed in an x-point divertor fusion device in the frame of the WEST (W-for tungsten-Environment in Steady-state Tokamak) project, launched in support to the ITER tungsten divertor strategy. The WEST project aims to test ITER-like W monoblock Plasma Facing Units (PFU). This ITER-like divertor will be tested under long plasma discharge up to 1000 s, with high heat flux density up to 20 MW/m 2 . This paper presents the results of ANSYS thermal-structural simulations of the WEST upper divertor. The upper divertor is made of twelve 30° sectors, each one composed of 38 PFU. The PFUs are actively cooled CuCrZr heat sinks and the incidence surface is coated with a thin tungsten layer. The fixing system is made of pins engaged in slotted holes. Besides, the fixing system of the sector assembly is the same as WEST lower divertor, so one upper divertor sector can be used indifferently in upper or Lower position during transitional operation phases in WEST. The total surface of the upper divertor is 8 m 2 , and it has to be able to extract up to 4 MW in steady-state, with peak heat flux values up to 8 MW/m 2 . The fixing system was designed to handle structural loads such as forces and torques resulting from halo and eddy current, respectively, especially during disruptions and Vertical Displacement Event (VDE). The torque resulting from eddy current is first calculated thanks to an internal CEA ANSYS APDL routine. Then the ANSYS structural and thermal-structural simulations of the PFU are presented, and its design is validated thanks to A-level RCC-MRx criteria. Finally, the most conservative load case is determined in order to validate the design of the pins and the support structure.

  13. Thermomechanical simulation of WEST actively cooled upper divertor

    Energy Technology Data Exchange (ETDEWEB)

    Batal, T., E-mail: tristan.batal@cea.fr; Richou, M.; Guilhem, D.; Firdaouss, M.; Larroque, S.; Ferlay, F.; Missirlian, M.; Bucalossi, J.

    2016-11-15

    The Tore Supra tokamak is being transformed in an x-point divertor fusion device in the frame of the WEST (W-for tungsten-Environment in Steady-state Tokamak) project, launched in support to the ITER tungsten divertor strategy. The WEST project aims to test ITER-like W monoblock Plasma Facing Units (PFU). This ITER-like divertor will be tested under long plasma discharge up to 1000 s, with high heat flux density up to 20 MW/m{sup 2}. This paper presents the results of ANSYS thermal-structural simulations of the WEST upper divertor. The upper divertor is made of twelve 30° sectors, each one composed of 38 PFU. The PFUs are actively cooled CuCrZr heat sinks and the incidence surface is coated with a thin tungsten layer. The fixing system is made of pins engaged in slotted holes. Besides, the fixing system of the sector assembly is the same as WEST lower divertor, so one upper divertor sector can be used indifferently in upper or Lower position during transitional operation phases in WEST. The total surface of the upper divertor is 8 m{sup 2}, and it has to be able to extract up to 4 MW in steady-state, with peak heat flux values up to 8 MW/m{sup 2}. The fixing system was designed to handle structural loads such as forces and torques resulting from halo and eddy current, respectively, especially during disruptions and Vertical Displacement Event (VDE). The torque resulting from eddy current is first calculated thanks to an internal CEA ANSYS APDL routine. Then the ANSYS structural and thermal-structural simulations of the PFU are presented, and its design is validated thanks to A-level RCC-MRx criteria. Finally, the most conservative load case is determined in order to validate the design of the pins and the support structure.

  14. Manufacturing W fibre-reinforced Cu composite pipes for application as heat sink in divertor targets of future nuclear fusion reactors

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Alexander v.; You, Jeong-Ha [Max-Planck-Institut fuer Plasmaphysik, 85748 Garching (Germany); Ewert, Dagmar [Institut fuer Textil- und Verfahrenstechnik Denkendorf, 73770 Denkendorf (Germany); Siefken, Udo [Louis Renner GmbH, 85221 Dachau (Germany)

    2016-07-01

    An important plasma-facing component (PFC) in future nuclear fusion reactors is the so-called divertor which allows power exhaust and removal of impurities from the main plasma. The most highly loaded parts of a divertor are the target plates which have to withstand intense particle bombardment. This intense particle bombardment leads to high heat fluxes onto the target plates which in turn lead to severe thermomechanical loads. With regard to future nuclear fusion reactors, an improvement of the performance of divertor targets is desirable in order to ensure reliable long term operation of such PFCs. The performance of a divertor target is most closely linked to the properties of the materials that are used for its design. W fibre-reinforced Cu (Wf/Cu) composites are regarded as promising heat sink materials in this respect. These materials do not only feature adequate thermophysical and mechanical properties, they do also offer metallurgical flexibility as their microstructure and hence their macroscopic properties can be tailored. The contribution will point out how Wf/Cu composites can be used to realise an advanced design of a divertor target and how these materials can be fabricated by means of liquid Cu infiltration.

  15. On the use of flat tile armour in high heat flux components

    Energy Technology Data Exchange (ETDEWEB)

    Merola, M.; Vieider, G

    1998-10-01

    The possibility to have a flat tile geometry for those high heat flux components subjected to a convective heat flux (namely the divertor dump target, lower vertical target, and the limiter) has been investigated. Because of the glancing incidence of the power load, if an armour tile falls off an extremely high heat flux hits the leading edge of the adjacent tile. As a result a rapid temperature increase occurs in the armour-heat sink joint. The heat flux to the water coolant also increases rapidly up to a factor of 1.7 and 2.3 for a beryllium and CFC armour, respectively, thus causing possible critical heat flux problems. Thermal stresses in the armour-heat sink joint double in less than 0.4 s and triplicate after 1 s thus leading to a possible cascade failure. Therefore the use of a flat tile geometry for these components does not seem to be appropriate. In this case a monoblock geometry gives a much more robust solution. (orig.) 7 refs.

  16. Development and testing of CFC-copper high heat flux elements

    International Nuclear Information System (INIS)

    Mitteau, R.; Chappuis, P.; Deschamps, P.; Schlosser, J.; Viallet, H.; Vieider, G.

    1994-01-01

    In the frame of high heat flux development for plasma facing components, CEA has designed, fabricated and tested over twenty specimens, with some of them for the NET divertor application. Several Carbon Fibre Composites (CFC) and copper grades have been used with flat tile or macro bloc configuration. All the mock-ups were tested in the electron beam facility EB200, for steady-state flux and fatigue up to 1000 cycles. The best four are presented. (author) 3 refs.; 11 figs

  17. The lithium vapor box divertor

    International Nuclear Information System (INIS)

    Goldston, R J; Schwartz, J; Myers, R

    2016-01-01

    It has long been recognized that volumetric dissipation of the plasma heat flux from a fusion power system is preferable to its localized impingement on a material surface. Volumetric dissipation mitigates both the anticipated very high heat flux and intense particle-induced damage due to sputtering. Recent projections to a tokamak demonstration power plant suggest an immense upstream parallel heat flux, of order 20 GW m −2 , implying that fully detached operation may be a requirement for the success of fusion power. Building on pioneering work on the use of lithium by Nagayama et al and by Ono et al as well as earlier work on the gas box divertor by Watkins and Rebut, we present here a concept for a lithium vapor box divertor, in which lithium vapor extracts momentum and energy from a fusion-power-plant divertor plasma, using fully volumetric processes. At the high powers and pressures that are projected this requires a high density of lithium vapor, which must be isolated from the main plasma in order to avoid lithium build-up on the chamber walls or in the plasma. Isolation is achieved through a powerful multi-box differential pumping scheme available only for condensable vapors. The preliminary box-wise calculations are encouraging, but much more work is required to demonstrate the practical viability of this scheme, taking into account at least 2D plasma and vapor flows within and between the vapor boxes and out of the vapor boxes to the main plasma. (paper)

  18. Dynamic divertor control using resonant mixed toroidal harmonic magnetic fields during ELM suppression in DIII-D

    Science.gov (United States)

    Jia, M.; Sun, Y.; Paz-Soldan, C.; Nazikian, R.; Gu, S.; Liu, Y. Q.; Abrams, T.; Bykov, I.; Cui, L.; Evans, T.; Garofalo, A.; Guo, W.; Gong, X.; Lasnier, C.; Logan, N. C.; Makowski, M.; Orlov, D.; Wang, H. H.

    2018-05-01

    Experiments using Resonant Magnetic Perturbations (RMPs), with a rotating n = 2 toroidal harmonic combined with a stationary n = 3 toroidal harmonic, have validated predictions that divertor heat and particle flux can be dynamically controlled while maintaining Edge Localized Mode (ELM) suppression in the DIII-D tokamak. Here, n is the toroidal mode number. ELM suppression over one full cycle of a rotating n = 2 RMP that was mixed with a static n = 3 RMP field has been achieved. Prominent heat flux splitting on the outer divertor has been observed during ELM suppression by RMPs in low collisionality regime in DIII-D. Strong changes in the three dimensional heat and particle flux footprint in the divertor were observed during the application of the mixed toroidal harmonic magnetic perturbations. These results agree well with modeling of the edge magnetic field structure using the TOP2D code, which takes into account the plasma response from the MARS-F code. These results expand the potential effectiveness of the RMP ELM suppression technique for the simultaneous control of divertor heat and particle load required in ITER.

  19. Response of NSTX liquid lithium divertor to high heat loads

    Energy Technology Data Exchange (ETDEWEB)

    Abrams, T., E-mail: tabrams@pppl.gov [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Jaworski, M.A. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Kallman, J. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Kaita, R. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Foley, E.L. [Nova Photonics, Inc., Princeton, NJ 08543 (United States); Gray, T.K. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Kugel, H. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Levinton, F. [Nova Photonics, Inc., Princeton, NJ 08543 (United States); McLean, A.G. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Skinner, C.H. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States)

    2013-07-15

    Samples of the NSTX Liquid Lithium Divertor (LLD) with and without an evaporative Li coating were directly exposed to a neutral beam ex-situ at a power of ∼1.5 MW/m{sup 2} for 1–3 s. Measurements of front face and bulk sample temperature were obtained. Predictions of temperature evolution were derived from a 1D heat flux model. No macroscopic damage occurred when the “bare” sample was exposed to the beam but microscopic changes to the surface were observed. The Li-coated sample developed a lithium hydroxide (LiOH) coating, which did not change even when the front face temperature exceeded the pure Li melting point. These results are consistent with the lack of damage to the LLD surface and imply that heating alone may not expose pure liquid Li if the melting point of surface impurities is not exceeded. This suggests that flow and heat are needed for future PFCs requiring a liquid Li surface.

  20. Rapidly Moving Divertor Plates In A Tokamak

    International Nuclear Information System (INIS)

    Zweben, S.

    2011-01-01

    It may be possible to replace conventional actively cooled tokamak divertor plates with a set of rapidly moving, passively cooled divertor plates on rails. These plates would absorb the plasma heat flux with their thermal inertia for ∼10-30 sec, and would then be removed from the vessel for processing. When outside the tokamak, these plates could be cooled, cleaned, recoated, inspected, and then returned to the vessel in an automated loop. This scheme could provide nearoptimal divertor surfaces at all times, and avoid the need to stop machine operation for repair of damaged or eroded plates. We describe various possible divertor plate designs and access geometries, and discuss an initial design for a movable and removable divertor module for NSTX-U.

  1. Radiative and SOL experiments in open and baffled divertors on DIII-D

    International Nuclear Information System (INIS)

    Allen, S.L.; Brooks, N.H.; Bastasz, R.

    1998-11-01

    The authors present recent progress towards an understanding of the physical processes in the divertor and scrape-off-layer (SOL) plasmas in DIII-D. This has been made possible by a combination of new diagnostics, improved computational models, and changes in divertor geometry. They have focused primarily on ELMing H-mode discharges. The physics of Partially Detached Divertor (PDD) plasmas, with divertor heat flux reduction by divertor radiation enhancement using D 2 puffing, has been studied in 2-D, and a model of the heat and particle transport has been developed that includes conduction, convection, ionization, recombination, and flows. Plasma and impurity particle flows have been measured with Mach probes and spectroscopy and these flows have been compared with the UEDGE model. The model now includes self-consistent calculations of carbon impurities. Impurity radiation has been increased in the divertor and SOL with puff and pump techniques using SOL D 2 puffing, divertor cryopumping, and argon puffing. The important physical processes in plasma-wall interactions have been examined with a DiMES probe, plasma characterization near the divertor plate, and the REDEP code. Experiments comparing single-null (SN) plasma operation in baffled and open divertors have demonstrated a change in the edge plasma profiles. These results are consistent with a reduction in the core ionization source calculated with UEDGE. Divertor particle control in ELMing H-mode with pumping and baffling has resulted in reduction in H-mode core densities to n e /n gw ∼ 0.25. Divertor particle exhaust and heat flux has been studied as the plasma shape was varied from a lower SN, to a balanced double null (DN), and finally to an upper SN

  2. Divertor design for the TITAN reversed-field-pinch reactor

    International Nuclear Information System (INIS)

    Cooke, P.I.H.; Bathke, C.G.; Blanchard, J.P.; Creedon, R.L.; Grotz, S.P.; Hasan, M.Z.; Orient, G.; Sharafat, S.; Werley, K.A.

    1987-01-01

    The design of the toroidal-field divertor for the TITAN high-power-density reversed-field-pinch reactor is described. The heat flux on the divertor target is limited to acceptable levels (≤ 10 MW/m 2 ) for liquid-lithium cooling by use of an open divertor geometry, strong radiation from the core and edge plasma, and careful shaping of the target surface. The divertor coils are based on the Integrated-Blanket-Coil approach to minimize the loss in breeding-blanket coverage due to the divertor. A tungsten-rhenium armour plate, chosen for reasons of sputtering resistance, and good thermal and mechanical properties, protects the vanadium-alloy coolant tubes

  3. Biased divertor performance under auxiliary heating conditions on the TdeV tokamak

    International Nuclear Information System (INIS)

    Decoste, R.; Lachambre, J.L.; Demers, Y.

    1994-01-01

    Plasma biasing has been shown on TdeV in the ohmic regime to be very promising for divertor applications. Negative biasing, with shortened SOL density gradients, improves the divertor performance, whereas positive biasing, with longer gradients, does not do much for the divertor. The next objectives were to extrapolate those results to auxiliary heated plasmas and optimize/simplify the biasing geometry for future upgrades. New results are now available with an improved divertor geometry and auxiliary heating/current drive provided by a new lower hybrid (LH) system. The new geometry, optimized for positive biasing with predictably acceptable negative biasing performances, allows for a fair comparison between the two polarities. (author) 4 refs., 5 figs

  4. Divertor power and particle fluxes between and during type-I ELMs in the ASDEX Upgrade

    Science.gov (United States)

    Kallenbach, A.; Dux, R.; Eich, T.; Fischer, R.; Giannone, L.; Harhausen, J.; Herrmann, A.; Müller, H. W.; Pautasso, G.; Wischmeier, M.; ASDEX Upgrade Team

    2008-08-01

    Particle, electric charge and power fluxes for type-I ELMy H-modes are measured in the divertor of the ASDEX Upgrade tokamak by triple Langmuir probes, shunts, infrared (IR) thermography and spectroscopy. The discharges are in the medium to high density range, resulting in predominantly convective edge localized modes (ELMs) with moderate fractional stored energy losses of 2% or below. Time resolved data over ELM cycles are obtained by coherent averaging of typically one hundred similar ELMs, spatial profiles from the flush-mounted Langmuir probes are obtained by strike point sweeps. The application of simple physics models is used to compare different diagnostics and to make consistency checks, e.g. the standard sheath model applied to the Langmuir probes yields power fluxes which are compared with the thermographic measurements. In between ELMs, Langmuir probe and thermography power loads appear consistent in the outer divertor, taking into account additional load due to radiation and charge exchange neutrals measured by thermography. The inner divertor is completely detached and no significant power flow by charged particles is measured. During ELMs, quite similar power flux profiles are found in the outer divertor by thermography and probes, albeit larger uncertainties in Langmuir probe evaluation during ELMs have to be taken into account. In the inner divertor, ELM power fluxes from thermography are a factor 10 larger than those derived from probes using the standard sheath model. This deviation is too large to be caused by deficiencies of probe analysis. The total ELM energy deposition from IR is about a factor 2 higher in the inner divertor compared with the outer divertor. Spectroscopic measurements suggest a quite moderate contribution of radiation to the target power load. Shunt measurements reveal a significant positive charge flow into the inner target during ELMs. The net number of elementary charges correlates well with the total core particle loss

  5. Engineering design of a Radiative Divertor for DIII-D

    International Nuclear Information System (INIS)

    Smith, J.P.; Allen, S.L.; Anderson, P.M.; Baxi, C.B.; Chin, E.; Fenstermacher, M.E.; Hill, D.N.; Hollerbach, M.A.; Hyatt, A.W.; Junge, R.; Mahdavi, M.A.; Porter, G.D.; Redler, K.; Reis, E.E.; Schaffer, M.J.; Sevier, D.L.; Stambaugh, R.D.

    1995-01-01

    A new divertor called the Radiative Divertor is presently being designed for the DIII-D tokamak. Input from tokamak experiments and modeling form the basis for the new design. The Radiative Divertor is intended to reduce the heat flux on the divertor plates by dispersing the power with radiation. Gas puffing experiments in the current open divertor have shown a reduction of the divertor heat flux with either deuterium or impurity puffing. However, either the plasma density (D 2 ) or the core Z eff (impurities) increases in these experiments. The radiative divertor uses a slot structure to isolate the divertor plasma region from the area surrounding the core plasma. Modeling has shown that the Radiative Divertor hardware will provide better baffling and particle control and thereby minimize the effect of the gas puffing in the divertor region on the plasma core. In addition, the Radiative Divertor structure will allow density control in plasma shapes with high triangularity (>0.8) required for advanced tokamak operation. The divertor structure allows for operation in either double or single-null plasma configurations. Four independently controlled divertor cryopumps will enable pumping at either the inboard (upper and lower) or the outboard (upper and lower) divertor plates. Biasing is an integral part of the design and is based on experience at the Tokamak de Varennes (TdeV) and DIII-D. Boron nitride tiles electrically insulate the inner and outer strike points and a low current electrode is used to apply a radial electric field to the scrape-off layer. TdeV has shown that biasing can provide particle and impurity control. The design is extremely flexible, and will allow physics studies of the effect of slot width and height. This is extremely important, as the amount of chamber volume needed for the divertor in future machines such as International Thermonuclear Experiment Reactor (ITER) and Tokamak Physics Experiment (TPX) must be determined. (orig./WL)

  6. An X-point ergodic divertor

    International Nuclear Information System (INIS)

    Chu, M.S.; Jensen, T.H.; La Haye, R.J.; Taylor, T.S.; Evans, T.E.

    1991-10-01

    A new ergodic divertor is proposed. It utilizes a system of external (n = 3) coils arranged to generate overlapping magnetic islands in the edge region of a diverted tokamak and connect the randomized field lines to the external (cold) divertor plate. The novel feature in the configuration is the placement of the external coils close to the X-point. A realistic design of the external coil set is studied by using the field line tracing method for a low aspect ratio (A ≅ 3) tokamak. Two types of effects are observed. First, by placing the coils close to the X-point, where the poloidal magnetic field is weak and the rational surfaces are closely packed only a moderate amount of current in the external coils is needed to ergodize the edge region. This ergodized edge enhances the edge transport in the X-point region and leads to the potential of edge profile control and the avoidance of edge localized modes (ELMs). Furthermore, the trajectories of the field lines close to the X-point are modified by the external coil set, causing the hit points on the external divertor plates to be randomized and spread out in the major radius direction. A time-dependent modulation of the currents in the external (n = 3) coils can potentially spread the heat flux more uniformly on the divertor plate avoiding high concentration of the heat flux. 10 refs., 9 figs

  7. Engineering challenges and development of the ITER Blanket System and Divertor

    Energy Technology Data Exchange (ETDEWEB)

    Merola, Mario, E-mail: mario.merola@iter.org; Escourbiac, Frederic; Raffray, Alphonse Rene; Chappuis, Philippe; Hirai, Takeshi; Gicquel, Stefan

    2015-10-15

    The ITER Blanket System and the Divertor are the main components which directly face the plasma. Being the first physical barrier to the plasma, they have very demanding design requirements, which include accommodating: (1) surface heat flux and neutronic volumetric heating, (2) electromagnetic loads, (3) nuclear shielding function, (4) capability of being assembled and remote-handled, (5) interfaces with other in-vessel components, and (6) high heat flux technologies and complex welded structures in the design. The main functions of the Blanket System have been substantially expanded and it has now also to provide limiting surfaces that define the plasma boundary during startup and shutdown. As regards the Divertor, the ITER Council decided in November 2013 to start the ITER operation with a full-tungsten armour in order to minimize costs and already gain operational experience with tungsten during the non-active phase of the machine. This paper gives an overview of the design and technology qualification of the Blanket System and the Divertor.

  8. Edge Recycling and Heat Fluxes in L- and H-mode NSTX Plasmas

    International Nuclear Information System (INIS)

    Soukhanovskii, V.A.; Maingi, R.; Raman, R.; Kugel, H.; LeBlanc, B.; Roquemore, A.L.; Lasnier, C.J.

    2003-01-01

    Introduction Edge characterization experiments have been conducted in NSTX to provide an initial survey of the edge particle and heat fluxes and their scaling with input power and electron density. The experiments also provided a database of conditions for the analyses of the NSTX global particle sources, core fueling, and divertor operating regimes

  9. Proposal of an alternative upper divertor in ASDEX Upgrade supported by EMC3-EIRENE simulations

    Directory of Open Access Journals (Sweden)

    T. Lunt

    2017-08-01

    Full Text Available We discuss the benefits of installing a pair of in-vessel coils with currents |Ifx| ≲ 50 kAt in the upper divertor of ASDEX Upgrade (AUG to study a series of ‘alternative’ divertor configurations, like the Snowflake (SF and the X-divertor (XD, that are currently considered as alternative solutions for the power exhaust problem. The possibility of operating the standard lower single-null (SN and double-null (DN would be preserved. Potential effects to reduce the peak parallel- and/or perpendicular heat flux are predicted from a simple geometrical-diffusive model as well as by numerical EMC3-EIRENE simulations for pure deuterium attached conditions with spatially constant diffusion coefficients. Beyond that a series of other potential transport- and radiation related heat flux mitigation effects are identified and could be studied experimentally with the modified upper divertor in the high-power divertor Tokamak AUG.

  10. Small angle slot divertor concept for long pulse advanced tokamaks

    Science.gov (United States)

    Guo, H. Y.; Sang, C. F.; Stangeby, P. C.; Lao, L. L.; Taylor, T. S.; Thomas, D. M.

    2017-04-01

    SOLPS-EIRENE edge code analysis shows that a gas-tight slot divertor geometry with a small-angle (glancing-incidence) target, named the small angle slot (SAS) divertor, can achieve cold, dissipative/detached divertor conditions at relatively low values of plasma density at the outside midplane separatrix. SAS exhibits the following key features: (1) strong enhancement of the buildup of neutral density in a localized region near the plasma strike point on the divertor target; (2) spreading of the cooling front across the divertor target with the slot gradually flaring out from the strike point, thus effectively reducing both heat flux and erosion on the entire divertor target surface. Such a divertor may potentially provide a power and particle handling solution for long pulse advanced tokamaks.

  11. Experimental investigation on heat transfer of HEMJ type divertor with narrow gap between nozzle and impingement surface

    International Nuclear Information System (INIS)

    Yokomine, Takehiko; Oohara, Ken; Kunugi, Tomoaki

    2016-01-01

    Highlights: • We performed heat transfer experiment on HEMJ-type multiple jet impingement. • For narrow gap case, degradation of heat transfer performance was observed. • The re-laminarization was anticipated if the temperature level is high. • For actual design of divertor cooling, the re-laminarization must be considered. - Abstract: In order to explore the possibility of improvement of the He-cooled modular divertor with multiple jet cooling (HEMJ) concept including optimization of design parameter, an experimental study on heat transfer performance of the HEMJ divertor was performed by means of helium loop at Georgia Tech, in which the pressure, flow rate and temperature of helium pressure is up to 10 MPa, 8 g/s and 300 °C, respectively, under heat flux of 6 MW/m"2 loaded by means of induction heater. Although the non-dimensional distance between jet nozzle and impingement surface H normalized by typical nozzle diameter D, H/D is 0.9 in the reference design of HEMJ, heat transfer experiments were carried out under the condition of H/D = 0.5 and 0.25 to enhance the heat transfer performance. In the case of H/D = 0.25, the averaged Nusselt number was increased by about 20% from the value for H/D = 0.5 in the case that the jet temperature less than 100 °C. By contraries, the averaged Nusselt number was decreased with increase in jet temperature which is larger than 200 °C in the H/D = 0.25 case. It is expected that the degradation of heat transfer performance with increasing the jet temperature is caused by the re-laminarization occurred near heat transfer surface.

  12. Current state-of-the-art manufacturing technology for He-cooled divertor finger

    Science.gov (United States)

    Norajitra, P.; Antusch, S.; Giniyatulin, R.; Mazul, I.; Ritz, G.; Ritzhaupt-Kleissl, H.-J.; Spatafora, L.

    2011-10-01

    A divertor concept for DEMO has been investigated at Karlsruhe Institute of Technology (KIT) which has to withstand a heat flux of 10 MW/m 2. The design utilizes small finger module composed of a small tungsten tile brazed on a thimble made from tungsten alloy. The divertor finger is cooled by helium jet impingement at 10 MPa and 600 °C. The subject of this paper is technological studies on machining and braze joining the divertor components. Goal of this task, which is considered an important R&D issue, is to find out appropriate manufacturing methods to ensure high functionality and high reliability of the divertor as well as to meet the economic aspect. One of the major requirements for manufacturing is micro-crack-free surface of tungsten parts, since crack propagations in tungsten were observed in the previous high-heat-flux tests at Efremov. Different manufacturing methods and the corresponding results are discussed in the following report.

  13. Two-dimensional numerical study of ELMs-induced erosion of tungsten divertor target tiles with different edge shapes

    International Nuclear Information System (INIS)

    Huang, Yan; Sun, Jizhong; Hu, Wanpeng; Sang, Chaofeng; Wang, Dezhen

    2016-01-01

    Highlights: • Thermal performance of three edge-shaped divertor tiles was assessed numerically. • All the divertor tiles exposed to type-I ELMs like ITER's will melt. • The rounded edge tile thermally performs the best in all tiles of interest. • The incident energy flux density was evaluated with structural effects considered. - Abstract: Thermal performance of the divertor tile with different edge shapes was assessed numerically along the poloidal direction by a two-dimensional heat conduction model with considering the geometrical effects of castellated divertor tiles on the properties of its adjacent plasma. The energy flux density distribution arriving at the castellated divertor tile surface was evaluated by a two-dimension-in-space and three-dimension-in-velocity particle-in-cell plus Monte Carlo Collisions code and then the obtained energy flux distribution was used as input for the heat conduction model. The simulation results showed that the divertor tiles with any edge shape of interest (rectangular edge, slanted edge, and rounded edge) would melt, especially, in the edge surface region of facing plasma poloidally under typical heat flux density of a transient event of type-I ELMs for ITER, deposition energy of 1 MJ/m"2 in a duration of 600 μs. In comparison with uniform energy deposition, the vaporizing erosion was reduced greatly but the melting erosion was aggravated noticeably in the edge area of plasma facing diveror tile. Of three studied edge shapes, the simulation results indicated that the divertor plate with rounded edge was the most resistant to the thermal erosion.

  14. Plasma characteristics of the end-cell of the GAMMA 10 tandem mirror for the divertor simulation experiment

    International Nuclear Information System (INIS)

    Nakashima, Y.; Sakamoto, M.; Yoshikawa, M.; Takeda, H.; Ichimura, K.; Hosoi, K.; Hirata, M.; Ichimura, M.; Ikezoe, R.; Imai, T.; Kariya, T.; Katanuma, I.; Kohagura, J.; Minami, R.; Numakura, T.; Oki, K.; Ueda, H.; Asakura, Nobuyuki; Furuta, T.; Hatayama, A.; Toma, M.; Hirooka, Y.; Masuzaki, S.; Sagara, A.; Shoji, M.; Kado, S.; Matsuura, H.; Nagata, S.; Nishino, N.; Ohno, N.; Tonegawa, A.; Ueda, Y.

    2012-11-01

    In this paper, detailed characteristics and controllability of plasmas emitted from the end-cell of the GAMMA 10 tandem mirror are described from the viewpoint of divertor simulation studies. The energy analysis of ion flux by using end-loss ion energy analyzer (ELIEA) proved that the obtained high ion temperature (100 - 400 eV) was comparable to SOL plasma parameters in toroidal devices and was controlled by changing the ICRF power. Parallel ion temperature T i∥ determined from the probe and calorimeter shows a linear relationship with the ICRF power in the central-cell and agrees with the results of ELIEA. Additional ICRF heating revealed a significant enhancement of particle flux, which indicated an effectiveness of additional plasma heating in adjacent cells toward the improvement of the performance. Superimposing the ECH pulse of 380 kW, 5 ms attained the maximum heat-flux more than 10 MW/m 2 on axis. This value comes up to the heat-load of the divertor plate of ITER, which gives a clear prospect of generating the required heat density for divertor studies by building up heating systems to the end-mirror cell. Initial results of plasma irradiation experiment and construction of new divertor module are also described. (author)

  15. Particle and heat balance analysis in scrape-off and divertor regions of the JFT-2M tokamak

    International Nuclear Information System (INIS)

    Nagashima, K.; Shoji, T.; Tamai, H.; Miura, Y.; Takenaga, H.; Maeda, H.

    1995-01-01

    Particle and heat balance in the scrape-off layer and the divertor region were studied in the JFT-2M tokamak. Using particle and energy conservation laws, particle and heat diffusivities perpendicular to the flux surface were evaluated just outside the magnetic separatrix. It was found that the particle diffusivity decreases with increasing electron density in the scrape-off layer and decreases by a factor of 2-3 in the H-mode phase as compared with that in L-mode. The heat diffusivity has almost the same dependence on the electron density. The ratio of the heat diffusivity to the particle diffusivity is about 2. ((orig.))

  16. Initial development of the DIII–D snowflake divertor control

    Science.gov (United States)

    Kolemen, E.; Vail, P. J.; Makowski, M. A.; Allen, S. L.; Bray, B. D.; Fenstermacher, M. E.; Humphreys, D. A.; Hyatt, A. W.; Lasnier, C. J.; Leonard, A. W.; McLean, A. G.; Maingi, R.; Nazikian, R.; Petrie, T. W.; Soukhanovskii, V. A.; Unterberg, E. A.

    2018-06-01

    Simultaneous control of two proximate magnetic field nulls in the divertor region is demonstrated on DIII–D to enable plasma operations in an advanced magnetic configuration known as the snowflake divertor (SFD). The SFD is characterized by a second-order poloidal field null, created by merging two first-order nulls of the standard divertor configuration. The snowflake configuration has many magnetic properties, such as high poloidal flux expansion, large plasma-wetted area, and additional strike points, that are advantageous for divertor heat flux management in future fusion reactors. However, the magnetic configuration of the SFD is highly-sensitive to changes in currents within the plasma and external coils and therefore requires complex magnetic control. The first real-time snowflake detection and control system on DIII–D has been implemented in order to stabilize the configuration. The control algorithm calculates the position of the two nulls in real-time by locally-expanding the Grad–Shafranov equation in the divertor region. A linear relation between variations in the poloidal field coil currents and changes in the null locations is then analytically derived. This formulation allows for simultaneous control of multiple coils to achieve a desired SFD configuration. It is shown that the control enabled various snowflake configurations on DIII–D in scenarios such as the double-null advanced tokamak. The SFD resulted in a 2.5×  reduction in the peak heat flux for many energy confinement times (2–3 s) without any adverse effects on core plasma performance.

  17. Development of a high-heat flux cooling element with potential application in a near-term fusion power plant divertor

    Energy Technology Data Exchange (ETDEWEB)

    Nicholas, Jack Robert, E-mail: jack.nicholas@eng.ox.ac.uk [Osney Thermo-Fluids Laboratory, University of Oxford, Oxford (United Kingdom); Ireland, Peter [Osney Thermo-Fluids Laboratory, University of Oxford, Oxford (United Kingdom); Hancock, David [CCFE, Culham, Oxfordshire (United Kingdom); Robertson, Dan [Rolls-Royce Plc., Derby, Derbyshire (United Kingdom)

    2015-10-15

    Highlights: • Laminate jet impingement system introduced for high pressure operation (17 MPa+). • Numerical thermo-fluid analysis on baseline geometry. • Cascade impingement shown to reduce divertor mass flow rate requirements and increase fluid temperature change. • Numerical thermo-fluid analysis validated using scaled experiments with air. - Abstract: A low temperature jet impingement based heat sink module has been developed for potential application in a near-term fusion power plant divertor. The design is composed of a number of hexagonal CuCrZr sheets bonded together in a stack to form a laminate structure. This method allows the production of complex flow paths using relatively simple manufacturing techniques. The thermo-fluid performance of a baseline design employing cascade jet impingement has been assessed and compared to a non-cascade case. Experimental validation of the numerical work was carried out on a scaled model using air as the working fluid. Local heat transfer coefficients were obtained on the surface using surface temperature data from thermochromic liquid crystals.

  18. Magnetic divertor design for the compact reversed-field pinch reactor

    International Nuclear Information System (INIS)

    Bathke, C.G.; Miller, R.L.; Krakowski, R.A.

    1984-01-01

    A recently completed design of a pumped-limiter-based Compact Reversed-Field Pinch Reactor is used to estimate for the first time the impact of magnetic divertors. A range of divertor options for the low-toroidal-field RFP is examined, and a design selection is made constrained by consideration of field ripple (magnetic island), blanket displacement, recirculating power, cost, heat flux, and access. Design choices based on diversion of minority (toroidal) field lead to a preference for (poloidally) symmetric or bundle divertor geometries

  19. Toroidal asymmetries in divertor impurity influxes in NSTX

    Directory of Open Access Journals (Sweden)

    F. Scotti

    2017-08-01

    Full Text Available Toroidal asymmetries in divertor carbon and lithium influxes were observed in NSTX, due to toroidal differences in surface composition, tile leading edges, externally-applied three-dimensional (3D fields and toroidally-localized edge plasma modifications due to radio frequency heating. Understanding toroidal asymmetries in impurity influxes is critical for the evaluation of total impurity sources, often inferred from measurements with a limited toroidal coverage. The toroidally-asymmetric lithium deposition induced asymmetries in divertor lithium influxes. Enhanced impurity influxes at the leading edge of divertor tiles were the main cause of carbon toroidal asymmetries and were enhanced during edge localized modes. Externally-applied 3D fields led to strike point splitting and helical lobes observed in divertor impurity emission, but marginal changes to the toroidally-averaged impurity influxes. Power coupled to the scrape-off layer SOL plasma during radio frequency (RF heating of H-mode discharges enhanced impurity influxes along the non-axisymmetric divertor footprint of flux tubes connecting to plasma in front of the RF antenna.

  20. Towards the development of workable acceptance criteria for the divertor CFC monoblock armour

    Energy Technology Data Exchange (ETDEWEB)

    D' Agata, E. [ITER International Team, ITER Joint Work Site, Boltzmannstr. 2, D-85748 Garching (Germany)]. E-mail: dagatae@itereu.de; Tivey, R. [ITER International Team, ITER Joint Work Site, Boltzmannstr. 2, D-85748 Garching (Germany)

    2005-11-15

    The plasma-facing components (PFCs) of the ITER divertor will be subjected to high heat flux (HHF). Carbon-fibre composite (CFC) is selected as the armour for the region of highest heat flux where the scrape-off layer of the plasma intercepts the vertical targets (VT). Failure of the armour to heat sink joints will compromise the performance of the divertor and could ultimately result in its failure and the shut down of the ITER machine. There are tens of thousands of CFCs to CuCrZr joints. The aim of the PFC design is to ensure that the divertor can continue to function even with the failure of a few joints. In preparation for writing the procurement specification for the ITER vertical target PFCs, a programme of work is underway with the objective of defining workable acceptance criteria for the PFC armour joints.

  1. Towards the development of workable acceptance criteria for the divertor CFC monoblock armour

    International Nuclear Information System (INIS)

    D'Agata, E.; Tivey, R.

    2005-01-01

    The plasma-facing components (PFCs) of the ITER divertor will be subjected to high heat flux (HHF). Carbon-fibre composite (CFC) is selected as the armour for the region of highest heat flux where the scrape-off layer of the plasma intercepts the vertical targets (VT). Failure of the armour to heat sink joints will compromise the performance of the divertor and could ultimately result in its failure and the shut down of the ITER machine. There are tens of thousands of CFCs to CuCrZr joints. The aim of the PFC design is to ensure that the divertor can continue to function even with the failure of a few joints. In preparation for writing the procurement specification for the ITER vertical target PFCs, a programme of work is underway with the objective of defining workable acceptance criteria for the PFC armour joints

  2. Design and performance study of the helium-cooled T-tube divertor concept

    International Nuclear Information System (INIS)

    Ihli, T.; Raffray, A.R.; Abdel-Khalik, S.I.; Shin, S.

    2007-01-01

    The ARIES-CS study has been launched with the goal of developing through physics and engineering optimization an attractive power plant concept based on a compact stellarator configuration. The study included an effort to characterize the divertor location and corresponding heat load distribution, and to develop a He-cooled divertor concept that could accommodate a heat flux of at least 10 MW/m 2 , and that would integrate well with the other power core components. This paper describes the design study of this divertor concept, which, although developed for a compact stellarator, is well suited for a tokamak configuration also

  3. The DIII-D Radiative Divertor Project: Status and plans

    International Nuclear Information System (INIS)

    Smith, J.P.; Baxi, C.B.; Bozek, A.S.

    1996-10-01

    New divertor hardware is being designed and fabricated for the Radiative Divertor modification of the DIII-D tokamak. The installation of the hardware has been separated into two phases, the first phase starting in October of 1996 and the second and final phase, in 1998. The phased approach enables the continuation of the divertor characterization research in the lower divertor while providing pumping for density control in high triangularity, single- or double-null advanced tokamak discharges. When completed, the Radiative Divertor Project hardware will provide pumping at all four strike points of a double-null, high triangularity discharge and provide baffling of the neutral particles from transport back to the core plasma. By puffing neutral gas into the divertor region, a reduction in the heat flux on the target plates will be be demonstrated without a large rise in core density. This reduction in heat flux is accomplished by dispersing the power with radiation in the divertor region. Experiments and modeling have formed the basis for the new design. The capability of the DIII-D cryogenic system is being upgraded as part of this project. The increased capability of the cryogenic system will allow delivery of liquid helium and nitrogen to three new cryopumps. Physics studies on the effects of slot width and length can be accomplished easily with the design of the Radiative Divertor. The slot width can be varied by installing graphite tiles of different geometry. The change in slot length, the distance from the X-point to the target plate, requires relocating the structure vertically and can be completed in about 6-8 weeks. Radiative Divertor diagnostics are being designed to provide comprehensive measurements for diagnosing the divertor. Required diagnostic modifications will be minimal for Phase 1, but extensive for Phase 2 installation. These Phase 2 diagnostics will be required to fully diagnose the high triangularity discharges in the divertor slots

  4. Parametric analyses of DEMO Divertor using two dimensional transient thermal hydraulic modelling

    Science.gov (United States)

    Domalapally, Phani; Di Caro, Marco

    2018-05-01

    Among the options considered for cooling of the Plasma facing components of the DEMO reactor, water cooling is a conservative option because of its high heat removal capability. In this work a two-dimensional transient thermal hydraulic code is developed to support the design of the divertor for the projected DEMO reactor with water as a coolant. The mathematical model accounts for transient 2D heat conduction in the divertor section. Temperature-dependent properties are used for more accurate analysis. Correlations for single phase flow forced convection, partially developed subcooled nucleate boiling, fully developed subcooled nucleate boiling and film boiling are used to calculate the heat transfer coefficients on the channel side considering the swirl flow, wherein different correlations found in the literature are compared against each other. Correlation for the Critical Heat Flux is used to estimate its limit for a given flow conditions. This paper then investigates the results of the parametric analysis performed, whereby flow velocity, diameter of the coolant channel, thickness of the coolant pipe, thickness of the armor material, inlet temperature and operating pressure affect the behavior of the divertor under steady or transient heat fluxes. This code will help in understanding the basic parameterś effect on the behavior of the divertor, to achieve a better design from a thermal hydraulic point of view.

  5. Examining Innovative Divertor and Main Chamber Options for a National Divertor Test Tokamak

    Science.gov (United States)

    Labombard, B.; Umansky, M.; Brunner, D.; Kuang, A. Q.; Marmar, E.; Wallace, G.; Whyte, D.; Wukitch, S.

    2016-10-01

    The US fusion community has identified a compelling need for a National Divertor Test Tokamak. The 2015 Community Planning Workshop on PMI called for a national working group to develop options. Important elements of a NDTT, adopted from the ADX concept, include the ability to explore long-leg divertor `solutions for power exhaust and particle control' (Priority Research Direction B) and to employ inside-launch RF actuators combined with double-null topologies as `plasma solution for main chamber wall components, including tools for controllable sustained operation' (PRD-C). Here we examine new information on these ideas. The projected performance of super-X and X-point target long-leg divertors is looking very promising; a stable fully-detached divertor condition handling an order-of-magnitude increase in power handling over conventional divertors may be possible. New experiments on Alcator C-Mod are addressing issues of high-field side versus low-field side heat flux sharing in double-null topologies and the screening of impurities that might originate from RF actuators placed in the high-field side - both with favorable results. Supported by USDoE Awards DE-FC02-99ER54512 and DE-AC52-07NA27344.

  6. EU Development of High Heat Flux Components

    International Nuclear Information System (INIS)

    Linke, J.; Lorenzetto, P.; Majerus, P.; Merola, M.; Pitzer, D.; Roedig, M.

    2005-01-01

    The development of plasma facing components for next step fusion devices in Europe is strongly focused to ITER. Here a wide spectrum of different design options for the divertor target and the first wall have been investigated with tungsten, CFC, and beryllium armor. Electron beam simulation experiments have been used to determine the performance of high heat flux components under ITER specific thermal loads. Beside thermal fatigue loads with power density levels up to 20 MWm -2 , off-normal events are a serious concern for the lifetime of plasma facing components. These phenomena are expected to occur on a time scale of a few milliseconds (plasma disruptions) or several hundred milliseconds (vertical displacement events) and have been identified as a major source for the production of neutron activated metallic or tritium enriched carbon dust which is of serious importance from a safety point of view.The irradiation induced material degradation is another critical concern for future D-T-burning fusion devices. In ITER the integrated neutron fluence to the first wall and the divertor armour will remain in the order of 1 dpa and 0.7 dpa, respectively. This value is low compared to future commercial fusion reactors; nevertheless, a nonnegligible degradation of the materials has been detected, both for mechanical and thermal properties, in particular for the thermal conductivity of carbon based materials. Beside the degradation of individual material properties, the high heat flux performance of actively cooled plasma facing components has been investigated under ITER specific thermal and neutron loads

  7. Micro- and nano-scale damage on the surface of W divertor component during exposure to high heat flux loads with He

    International Nuclear Information System (INIS)

    Li, C.; Greuner, H.; Zhao, S.X.; Böswirth, B.; Luo, G.N.; Zhou, X.; Jia, Y.Z.; Liu, X.; Liu, W.

    2015-01-01

    Micro- and nano-scale surface damage on a W divertor component sample exposed to high heat flux loads generated with He atoms has been investigated through SEM, EBSD, AFM and FIB-SEM. The component sample was supplied by the Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP) and AT&M company, China, and the loading experiment was performed in the GLADIS facility at IPP Garching, Germany. Two typical damage structures were observed on the surface: the first one is characterized by obvious blisters and some grooves formed from ruptured blisters, and the other one is a kind of porous structure accompanying with at least ∼25 nm surface material loss. As the grain orientation is further away from , the damage morphology gradually changes from the former structure to the latter. The possible damage mechanism is discussed. - Highlights: • Two damage structures were observed on W component surface under He beam heating. • Blistering was more obvious in near grains. • Porous structure appeared in the grains away from . • A loose layer caused by He aggregation was formed in near-surface region.

  8. A snowflake divertor: a possible solution to the power exhaust problem for tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Ryutov, D. D.; Cohen, R. H.; Rognlien, T. D.; Umansky, M. V.

    2012-11-21

    This paper summarizes recent progress in the theory of a snowflake divertor, a possible path to reduce both steady-state and intermittent heat loads on the divertor plates to an acceptable level. The most important feature of a SF divertor is the presence of a large zone of a very weak poloidal magnetic field around the poloidal field (PF) null. Qualitative explanation of a variety of new features characteristic of a SF divertor is provided based on simple scaling relations. The main part of the paper is focused on the concept of spreading of the heat flux by curvature-driven convection near the PF null. References to experimental results from the NSTX and TCV tokamaks are provided.

  9. Divertor development for ITER

    International Nuclear Information System (INIS)

    Janeschitz, G.; Ando, T.; Antipenkov, A.; Barabash, V.; Chiocchio, S.; Federici, G.; Ibbott, C.; Jakeman, R.; Matera, R.; Martin, E.; Parker, R.; Tivey, R.; Pacher, H.D.

    1998-01-01

    The requirements for the ITER divertor design, i.e. power and He ash exhaust, neutral leakage control, lifetime, disruption load resistance and exchange by remote handling, are described in this paper. These requirements and the physics requirements for detached and semi-attached operation result in the vertical target configuration. This is realised by a concept incorporating 60 cassettes carrying the high heat flux components. The armour choice for these components is CFC monoblock in the strike zone near at the lower part of the vertical target, and a W brush elsewhere. Cooling is by swirl tubes or hypervapotrons depending on the component. The status of the heat sink and joining technology R and D is given. Finally, the resulting design of the high heat flux components is presented. (orig.)

  10. Optimization for steady-state and hybrid operations of ITER by using scaling models of divertor heat load

    International Nuclear Information System (INIS)

    Murakami, Yoshiki; Itami, Kiyoshi; Sugihara, Masayoshi; Fujieda, Hirobumi.

    1992-09-01

    Steady-state and hybrid mode operations of ITER are investigated by 0-D power balance calculations assuming no radiation and charge-exchange cooling in divertor region. Operation points are optimized with respect to divertor heat load which must be reduced to the level of ignition mode (∼5 MW/m 2 ). Dependence of the divertor heat load on the variety of the models, i.e., constant-χ model, Bohm-type-χ model and JT-60U empirical scaling model, is also discussed. The divertor heat load increases linearly with the fusion power (P FUS ) in all models. The possible highest fusion power much differs for each model with an allowable divertor heat load. The heat load evaluated by constant-χ model is, for example, about 1.8 times larger than that by Bohm-type-χ model at P FUS = 750 MW. Effect of reduction of the helium accumulation, improvements of the confinement capability and the current-drive efficiency are also investigated aiming at lowering the divertor heat load. It is found that NBI power should be larger than about 60 MW to obtain a burn time longer than 2000 s. The optimized operation point, where the minimum divertor heat load is achieved, does not depend on the model and is the point with the minimum-P FUS and the maximum-P NBI . When P FUS = 690 MW and P NBI = 110 MW, the divertor heat load can be reduced to the level of ignition mode without impurity seeding if H = 2.2 is achieved. Controllability of the current-profile is also discussed. (J.P.N.)

  11. Simulation of divertor targets shielding during transients in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Pestchanyi, Sergey, E-mail: serguei.pestchanyi@kit.edu [KIT, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen (Germany); Pitts, Richard; Lehnen, Michael [ITER Organization,Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2016-11-01

    Highlights: • We simulated plasma shielding effect during disruption in ITER using the TOKES code. • It has been found that vaporization is unavoidable under action of ITER transients, but plasma shielding drastically reduces the divertor target damage: the melt pool and the vaporization region widths reduced 10–15 times. • A simplified 1D model describing the melt pool depth and the shielded heat flux to the divertor targets have been developed. • The results of the TOKES simulations have been compared with the analytic model when the model is valid. - Abstract: Direct extrapolation of the disruptive heat flux on ITER conditions predicts severe melting and vaporization of the divertor targets causing their intolerable damage. However, tungsten vaporized from the target at initial stage of the disruption can create plasma shield in front of the target, which effectively protects the target surface from the rest of the heat flux. Estimation of this shielding efficiency has been performed using the TOKES code. The shielding effect under ITER conditions is found to be very strong: the maximal depth of the melt layer reduced 4 times, the melt layer width—more than 10 times and vaporization region shrinks 10–15 times due to shielding for unmitigated disruption of 350 MJ discharge. The simulation results show complex, 2D plasma dynamics of the shield under ITER conditions. However, a simplified analytic model, valid for rough estimation of the maximum value for the shielded flux to the target and for the melt depth at the target surface has been developed.

  12. Divertor modeling for the design of the National Centralized Tokamak with high beta steady-state plasmas

    International Nuclear Information System (INIS)

    Kawashima, H.; Sakurai, S.; Shimizu, K.; Takizuka, T.; Tamai, H.; Matsukawa, M.; Fujita, T.; Miura, Y.

    2006-01-01

    The modification of the JT-60U to a fully superconducting coil tokamak, National Centralized Tokamak (NCT) facility, has been programmed to accomplish the high beta steady-state plasma research. A 2D divertor simulation code, SOLDOR/NEUT2D, is applied to the construction of a database for optimum design of the divertor. A semi-closed divertor configuration with vertical target is adopted as the first conceptual divertor design on NCT. With an anticipated SOL power flux of 12 MW at the high beta steady-state operation, the peak heat load on the divertor target is evaluated to be ∼16 MW/m 2 . Effects of divertor geometry and intense gas puffing are demonstrated with a view to reduce the heat load. For the simulation of divertor pumping, we find that the pumping efficiency increases by a factor of 2∼3 by narrowing the divertor gap from 20 to 5 cm. An attractive feature in reducing the heat load and improving the particle controllability has been obtained for a new divertor design due to a recent progress in NCT design

  13. Modular He-cooled divertor for power plant application

    International Nuclear Information System (INIS)

    Diegele, Eberhard; Kruessmann, R.; Malang, S.; Norajitra, P.; Rizzi, G.

    2003-01-01

    Gas cooled divertor concepts are regarded as a suitable option for fusion power plants because of an increased thermal efficiency for power conversion systems and the use of a coolant compatible with all blanket systems. A modular helium cooled divertor concept is proposed with an improved heat transfer. The concept employs small tiles made of tungsten and brazed to a finger-like structure made of Mo-alloy (TZM). Design goal was a heat flux of at least 15 MW/m 2 and a minimum temperature of the structure of 600 deg.C. The divertor has to survive a number of cycles (100-1000) between operating temperature and room temperature even for the steady state operation assumed. Thermo-hydraulic design requirements for the concepts include to keep the pumping power below 10% of the thermal power to the divertor plates, and simultaneously achieving a heat transfer coefficient in excess of 60 kW/m 2 K. Inelastic stress analysis indicates that design allowable stress limits on primary and secondary (thermal) stresses as required by the ITER structural design criteria are met even under conservative assumptions. Finally, critical issues for future development are addressed

  14. The high-heat-flux test facilities in the joint stock company “D.V. Efremov Institute of Electrophysical Apparatus”

    Energy Technology Data Exchange (ETDEWEB)

    Volodin, A., E-mail: volodin@sintez.niiefa.spb.su [JSC “NIIEFA”, 196641 St. Petersburg (Russian Federation); Kuznetcov, V.; Davydov, V.; Kokoulin, A.; Komarov, A.; Mazul, I.; Mudyugin, B.; Ovchinnikov, I.; Stepanov, N.; Rulev, R.; Eremkin, A.; Rogov, A.; Prianikov, V. [JSC “NIIEFA”, 196641 St. Petersburg (Russian Federation); Fedosov, A. [ITER Organization, Building 81/124, TKM, Internal Components Division, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France)

    2015-10-15

    Highlights: • The IDTF was created for the high heat flux tests of the PFUs of the ITER divertor. • At the present on the TSEFEY-M a brazing of fingers a FW semi-prototype is performing. • The IDTF and TSEFEY-M facilities are ready for the HHF testing of the ITER components. - Abstract: The current ITER design involves beryllium and tungsten as plasma facing materials for in-vessel components. Due to a high number of operating cycles and to the expected surface heat loads, thermal fatigue is one of the most damaging mechanisms for the plasma facing components (PFCs) of the ITER machine. Therefore, it is essential to perform an assessment of the behavior of PFCs under cycling heat loads to demonstrate the fitness for purpose of the selected technologies. This article summarizes the features of high heat flux facilities designed and constructed in the Efremov Institute for the performance of high heat flux (HHF) tests under ITER procurements as well as related R&D works. The TSEFEY-M facility was commissioned in 1994. The main purpose of this facility is thermal fatigue testing of mock-ups with various plasma-facing materials (carbon fiber reinforced composite (CFC), tungsten, beryllium, etc.) and with various cooling agents (water or gas). The ITER divertor test facility (IDTF) was created in the framework of ITER project, specifically for the HHF tests of the vertical targets (inner and outer) and domes of the ITER divertor. After commissioning in 2008, the IDTF facility was qualified in 2012–2013 for HHF tests of ITER PFCs.

  15. Evaluation of helium cooling for fusion divertors

    International Nuclear Information System (INIS)

    Baxi, C.B.

    1993-09-01

    The divertors of future fusion reactors will have a power throughput of several hundred MW. The peak heat flux on the diverter surface is estimated to be 5 to 15 MW/m 2 at an average heat flux of 2 MW/m 2 . The divertors have a requirement of both minimum temperature (100 degrees C) and maximum temperature. The minimum temperature is dictated by the requirement to reduce the absorption of plasma, and the maximum temperature is determined by the thermo-mechanical properties of the plasma facing materials. Coolants that have been considered for fusion reactors are water, liquid metals and helium. Helium cooling has been shown to be very attractive from safety and other considerations. Helium is chemically and neutronically inert and is suitable for power conversion. The challenges associated with helium cooling are: (1) Manifold sizes; (2) Pumping power; and (3) Leak prevention. In this paper the first two of the above design issues are addressed. A variety of heat transfer enhancement techniques are considered to demonstrate that the manifold sizes and the pumping power can be reduced to acceptable levels. A helium-cooled diverter module was designed and fabricated by GA for steady-state heat flux of 10 MW/m 2 . This module was recently tested at Sandia National Laboratories. At an inlet pressure of 4 MPa, the module was tested at a steady-state heat flux of 10 MW/m 2 . The pumping power required was less than 1% of the power removed. These results verified the design prediction

  16. The effect of feedback-controlled divertor nitrogen seeding on the boundary plasma and power exhaust channel width in Alcator C-Mod

    Science.gov (United States)

    Labombard, B.; Brunner, D.; Kuang, A. Q.; McCarthy, W.; Terry, J. L.

    2017-10-01

    The scrape-off layer (SOL) power channel width, λq, is projected to be 0.5 mm in power reactors, based on multi-machine measurements of divertor target heat fluxes in H-mode at low levels of divertor dissipation. An important question is: does λq change with the level of divertor dissipation? We report results in which feedback controlled nitrogen seeding in the divertor was used to systematically vary divertor dissipation in a series of otherwise identical L-mode plasmas at three plasma currents: 0.55, 0.8 and 1.1 MA. Outer midplane profiles were recorded with a scanning Mirror Langmuir Probe; divertor plasma conditions were monitored with `rail' Langmuir probe and surface thermocouple arrays. Despite an order of magnitude reduction in divertor target heat fluxes (q// 400 MW m-2 to 40 MW m-2) and corresponding change in divertor regime from sheath-limited through high-recycling to near-detached, the upstream electron temperature profile is found to remain unchanged or to become slightly steeper in the near SOL and to drop significantly in the far SOL. Thus heat in the SOL appears to take advantage of this impurity radiation `heat sink' in the divertor by preferentially draining via the narrow (and perhaps an increasingly narrow) λq of the near SOL. Supported by USDoE award DE-FC02-99ER54512.

  17. Studies of power exhaust and divertor design for a 1.5 GW-level fusion power DEMO

    Science.gov (United States)

    Asakura, N.; Hoshino, K.; Suzuki, S.; Tokunaga, S.; Someya, Y.; Utoh, H.; Kudo, H.; Sakamoto, Y.; Hiwatari, R.; Tobita, K.; Shimizu, K.; Ezato, K.; Seki, Y.; Ohno, N.; Ueda, Y.; Joint Special TeamDEMO Design

    2017-12-01

    Power exhaust to the divertor and the conceptual design have been investigated for a steady-state DEMO in Japan with 1.5 GW-level fusion power and the major radius of 8.5 m, where the plasma parameters were revised appropriate for the impurity seeding scenario. A system code survey for the Ar impurity seeding suggested the volume-averaged density, impurity concentration and exhaust power from the main plasma of {{P}sep ~ }   =  205-285 MW. The divertor plasma simulation (SONIC) was performed in the divertor leg length of 1.6 m with the fixed exhaust power to the edge of {{P}out}   =  250 MW and the total radiation fraction at the edge, SOL and divertor ({{P}rad}/{{P}out}   =  0.8), as a first step to investigate appropriate design of the divertor size and geometry. At the outer target, partial detachment was produced near the strike-point, and the peak heat load ({{q}target} ) at the attached region was reduced to ~5 MW m-2 with appropriate fuel and impurity puff rates. At the inner divertor target, full detachment of ion flux was produced and the peak {{q}target} was less than 10 MW m-2 mostly due to the surface-recombination. These results showed a power exhaust scenario and the divertor design concept. An integrated design of the water-cooling heat sink for the long leg divertor was proposed. Cu-ally (CuCrZr) cooling pipe was applicable as the heat sink to handle the high heat flux near the strike-point, where displacements per atom rate was estimated to be 0.5-1.5 per year by neutronics calculation. An arrangement of the coolant rooting for Cu-alloy and Reduced Activation Ferritic Martensitic (RAFM) steel (F82H) pipes in a divertor cassette was investigated, and the heat transport analysis of the W-monoblock and Cu-alloy pipe under the peak {{q}target} of 10 MWm-2 and nuclear heating was performed. The maximum temperatures on the W-surface and Cu-alloy pipe were 1021 and 331 °C. Heat flux of 16 MW m-2 was distributed in the major part

  18. Development of a radiative divertor for DIII-D

    International Nuclear Information System (INIS)

    Allen, S.L.; Brooks, N.H.; Campbell, R.B.; Fenstermacher, M.E.; Hill, D.N.; Hyatt, A.W.; Knoll, D.; Lasnier, C.J.; Lazarus, E.A.; Leonard, A.W.; Lippmann, S.I.; Mahdavi, M.A.; Maingi, R.; Meyer, W.; Moyer, R.A.; Petrie, T.W.; Porter, G.D.; Rensink, M.E.; Rognlien, T.D.; Schaffer, M.J.; Smith, J.P.; Staebler, G.M.; Stambaugh, R.D.; West, W.P.; Wood, R.D.

    1995-01-01

    We have used experiments and modeling to develop a new radiative divertor configuration for DIII-D. Gas puffing experiments with the existing open divertor have shown the creation of a localized ( similar 10 cm diameter) radiation zone which results in substantial reduction (3-10) in the divertor heat flux while τ E remains similar 2 times ITER-89P scaling. However, n e increases with D 2 puffing, and Z eff increases with neon puffing. Divertor structures are required to minimize the effects on the core plasma. The UEDGE fluid code, benchmarked with DIII-D data, and the DEGAS neutrals transport code are used to estimate the effectiveness of divertor configurations; slots reduce the core ionization more than baffles. The overall divertor shape is set by confinement studies which indicate that high triangularity (δ∼0.8) is important for high τ E VH-modes. Results from engineering feasibility studies, including diagnostic access, will be presented. ((orig.))

  19. Development of a radiative divertor for DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Allen, S.L. [Lawrence Livermore National Lab., CA (United States); Brooks, N.H. [General Atomics, San Diego, CA (United States); Campbell, R.B. [Sandia National Labs., Albuquerque, NM (United States); Fenstermacher, M.E. [Lawrence Livermore National Lab., CA (United States); Hill, D.N. [Lawrence Livermore National Lab., CA (United States); Hyatt, A.W. [General Atomics, San Diego, CA (United States); Knoll, D.; Lasnier, C.J. [Lawrence Livermore National Lab., CA (United States); Lazarus, E.A. [Oak Ridge National Lab., TN (United States); Leonard, A.W. [General Atomics, San Diego, CA (United States); Lippmann, S.I. [General Atomics, San Diego, CA (United States); Mahdavi, M.A. [General Atomics, San Diego, CA (United States); Maingi, R. [Oak Ridge National Lab., TN (United States); Meyer, W. [Lawrence Livermore National Lab., CA (United States); Moyer, R.A. [California Univ., Los Angeles, CA (United States); Petrie, T.W. [General Atomics, San Diego, CA (United States); Porter, G.D. [Lawrence Livermore National Lab., CA (United States); Rensink, M.E. [Lawrence Livermore National Lab., CA (United States); Rognlien, T.D. [Lawrence Livermore National Lab., CA (United States); Schaffer, M.J. [General Atomics, San Diego, CA (United States); Smith, J.P. [General Atomics, San Diego, CA (United States); Staebler, G.M. [General Atomics, San Diego, CA (United States); Stambaugh, R.D. [General Atomics, San Diego, CA (United States); West, W.P. [General Atomics, San Diego, CA (United States); Wood, R.D. [Lawrence Livermore National Lab., CA (United States)

    1995-04-01

    We have used experiments and modeling to develop a new radiative divertor configuration for DIII-D. Gas puffing experiments with the existing open divertor have shown the creation of a localized ( similar 10 cm diameter) radiation zone which results in substantial reduction (3-10) in the divertor heat flux while {tau}{sub E} remains similar 2 times ITER-89P scaling. However, n{sub e} increases with D{sub 2} puffing, and Z{sub eff} increases with neon puffing. Divertor structures are required to minimize the effects on the core plasma. The UEDGE fluid code, benchmarked with DIII-D data, and the DEGAS neutrals transport code are used to estimate the effectiveness of divertor configurations; slots reduce the core ionization more than baffles. The overall divertor shape is set by confinement studies which indicate that high triangularity ({delta}{approx}0.8) is important for high {tau}{sub E} VH-modes. Results from engineering feasibility studies, including diagnostic access, will be presented. ((orig.)).

  20. Engineering design of a radiative divertor for DIII-D

    International Nuclear Information System (INIS)

    Smith, J.P.; Baxi, C.B.; Bozek, A.S.

    1995-10-01

    A new divertor configuration is being developed for the DIII-D tokamak. This divertor will operate in the radiative mode. Experiments and modeling form the basis for the new design. The Radiative Divertor reduces the heat flux on the divertor plates by dispersing the power with radiation in the divertor region. In addition, the Radiative Divertor structure will allow density control in plasma shapes required for advanced tokamak operation. The divertor structure allows for operation in either double-null or single-null plasma configurations. Four independently controlled divertor cryopumps will enable pumping at either the inboard (upper and lower) or the outboard (upper and lower) divertor plates. An upgrade to the DIII-D cryogenic system is part of this project. The increased capabilities of the cryogenic system will allow delivery of liquid helium and nitrogen to the three new cryopumps. The Radiative Divertor design is very flexible, and will allow physics studies of the effects of slot width and length. Radiative Divertor diagnostics are being designed in parallel to provide comprehensive measurements for diagnosing the divertor. The Radiative divertor installation is scheduled for late 1996. Engineering experience gained in the DIII-D Advanced Divertor program form a foundation for the design work on the Radiative Divertor

  1. Comprehending the structure of a vacuum vessel and in-vessel components of fusion machines. 2. Comprehending the divertor structure

    International Nuclear Information System (INIS)

    Suzuki, Satoshi; Akiba, Masato; Saito, Masakatsu

    2006-01-01

    Divertor is given the largest heat load in the in-vessel components of fusion machine. The functions and conditions of divertor are stated from the point of view of thermal and structural dynamics. The way of thinking of structure design of divertor of JT-60 and the ITER (International Thermonuclear Experimental Reactor) is explained. As the conditions of divertor, the materials for large heat load, heat removal, pressure boundary, control of damage, and thermal stress/strain are considered. The divertor has to be changed periodically. The materials are required the heat removal function for high heat load. CuCrZr will be used to cooling tube and heat sink, and CFC materials for the surface. The cross section of ITER, a part of divertor, heat load of divertor and other components, the thermal conductivity of CFC and metal materials, conditions of cooling water for divertor of BWR, PWR and ITER, the thermal stress produced on rod, vertical target of ITER, structure of cooling tube, distribution of temperature and critical heart flux of inner wall of cooling tube, and fatigue clack of cooling tube are shown. (S.Y.)

  2. FEM investigation and thermo-mechanic tests of the new solid tungsten divertor tile for ASDEX Upgrade

    International Nuclear Information System (INIS)

    Jaksic, Nikola; Greuner, Henri; Herrmann, Albrecht

    2013-01-01

    Highlights: • New solid tungsten divertor for fusion experiment ASDEX Upgrade. • Design validation in the high heat flux (HHF) test facility GLADIS (Garching Large Divertor Sample Test Facility). • FEA simulation. -- Abstract: A new solid tungsten divertor for the fusion experiment ASDEX Upgrade is under construction at present. A new divertor tile design has been developed to improve the thermal performance of the current divertor made of tungsten coated fine grain graphite. Compared to thin tungsten coatings, divertor tiles made of massive tungsten allow to extend the operational range and to study the plasma material interaction of tungsten in more detail. The improved design for the solid tungsten divertor was tested on different full scale prototypes with a hydrogen ion beam. The influence of a possible material degradation due to thermal cracking or recrystallization can be studied. Furthermore, intensive Finite Element Method (FEM) numerical analysis with the respective test parameters has been performed. The elastic–plastic calculation was applied to analyze thermal stress and the observed elastic and plastic deformation during the heat loading. Additionally, the knowledge gained by the tests and especially by the numerical analysis has been used to optimize the shape of the divertor tiles and the accompanying divertor support structure. This paper discusses the main results of the high heat flux tests and their numerical simulations. In addition, results from some special structural mechanic analysis by means of FEM tools are presented. Finally, first results from the numerical lifecycle analysis of the current tungsten tiles will be reported

  3. Liquid metal cooled divertor for ARIES

    International Nuclear Information System (INIS)

    Muraviev, E.

    1995-01-01

    A liquid metal, Ga-cooled divertor design was completed for the double null ARIES-II divertor design. The design analysis indicated a surface heat flux removal capability of up to 15 MW/m 2 , and its relative easy maintenance. Design issues of configuration, thermal hydraulics, thermal stresses, liquid metal loop and safety effects were evaluated. For coolant flow control, it was found that it is necessary to use some part of the blanket cooling ducts for the draining of liquid metal from the top divertor. In order to minimize the inventory of Ga, it was recommended that the liquid metal loop equipment should be located as close to the torus as possible. More detailed analysis of transient conditions especially under accident conditions was identified as an issue that will need to be addressed

  4. Plasma shape control calculations for BPX divertor design

    International Nuclear Information System (INIS)

    Strickler, D.J.; Neilson, G.H.; Jardin, S.C.; Pomphrey, N.

    1991-01-01

    The Burning Plasma Experiment (BPX) divertor is to be capable of withstanding heat loads corresponding to ignited operation and 500 MW of fusion power for a current rise time and flattop lasting several seconds. The poloidal field (PF), diagnostic, and feedback equilibrium control systems must provide precise X-point position control in order to sweep the separatrices across the divertor target surface and optimally distribute the heat loads. A control matrix MHD equilibrium code, BEQ, and the Tokamak Simulation Code (TSC) are used to compute preprogrammed double-null (DN) divertor sweep trajectories that maximize sweep distance while simultaneously satisfying a set of strict constraints: minimum lengths of the field lines between the X-point and strike points, minimum spacing between the inboard plasma edge and the limiter, maximum spacing between the outboard plasma edge and the ICRF antennas, minimum safety factor, and linked poloidal flux. A sequence of DN diverted equilibria and a consistent TSC fiducial discharge simulation are used in evaluating the performance of the BPX divertor shape and possible modifications. 5 refs., 10 figs

  5. H-mode WEST tungsten divertor operation: deuterium and nitrogen seeded simulations with SOLEDGE2D-EIRENE

    Directory of Open Access Journals (Sweden)

    G. Ciraolo

    2017-08-01

    Full Text Available Simulations of WEST H-mode divertor scenarios have been performed with SOLEDGE2D-EIRENE edge plasma transport code, both for pure deuterium and nitrogen seeded discharge. In the pure deuterium case, a target heat flux of 8 MW/m2 is reached, but misalignment between heat and the particle outflux yields 50 eV plasma temperature at the target plates. With nitrogen seeding, the heat and particle outflux are observed to be aligned so that lower plasma temperatures at the target plates are achieved together with the required high heat fluxes. This change in heat and particle outflux alignment is analysed with respect to the role of divertor geometry and the impact of vertical vs horizontal target plates on neutrals spreading.

  6. Divertor radiation in the ASDEX upgrade tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Sehmer, Till; Bernert, Matthias; Koll, Juergen; Meister, Hans; Wischmeier, Marco; Fantz, Ursel [Max-Planck-Institut fuer Plasmaphysik, Boltzmannstrasse 2, 85748 Garching (Germany); Reimold, Felix [Forschungszentrum Juelich GmbH, Institut fuer Energie- und Klimaforschung - Plasmaphysik, 52425 Juelich (Germany); Collaboration: The ASDEX Upgrade Team

    2016-07-01

    To reduce in ITER the expected power flux density onto the divertor target, the plasma-wall interaction in the divertor needs to be strongly reduced. The fundamental path to achieve this is using radiation from seeded impurities, whereas the localization of this radiation (e.g. inside/outside confined region), which could have an impact onto the power balance, is a key challenge. The absolute radiated power distribution can be measured by foil bolometers. To study at the ASDEX Upgrade tungsten divertor the localization and quantification of radiation, the respective line of sight density of the bolometers has been improved by two additional cameras. The divertor radiation enhanced by nitrogen (N{sub 2}) seeding has been investigated, using variations of (1) the external heating power or (2) the N{sub 2} seeding rate. While in both cases the inner divertor stays fully detached, measurements indicate that the region of dominant radiation moves from the inner divertor through the X-Point into the confined region. In the outer divertor however, the measurements indicate either an immediate upwards shift or a continuous movement of the radiation away from the target, depending on experimental conditions.

  7. Thermal and structural analysis of the TPX divertor

    International Nuclear Information System (INIS)

    Reis, E.E.; Baxi, C.B.; Chin, E.; Redler, K.M.

    1995-01-01

    The high heat flux on the surfaces of the TPX divertor will require a design in which a carbon-carbon (C-C) tile material is brazed to water cooled copper tubes. Thermal and structural analyses were performed to assist in the design selection of a divertor tile concept and C-C material. The relevancy of finite element analysis (FEA) for evaluating tile design was examined by conducting a literature survey to compare FEA stress results to subsequent brazing and thermal test results. The thermal responses for five tile concepts and four C-C materials were analyzed for a steady-state heat flux of 7.5 MW/m 2 . Elastic-plastic stress analyses were performed to calculate the residual stresses due to brazing C-C tiles to soft copper heat sinks for the various tile designs. Monoblock and archblock divertor tile concepts were analyzed for residual stresses in which elevated temperature creep effects were included with the elastic-plastic behavior of the copper heat sink for an assumed braze cooldown cycle. As a result of these 2D studies, the archblock concept with a 3D fine weave C-C was initially found to be a preferred design for the divertor. A 3D elastic-plastic analysis for brazing of the arch block tile was performed to investigate the singularity effects at the C-C to copper interface in the direction of the tube axis. This analysis showed that the large residual stresses at the tube and tile edge intersection would produce cracks in the C-C and possible delamination along the braze interface. These results, coupled with the difficulties experienced in brazing archblocks for the Tore Supra Limiter, required that other tile designs be considered

  8. Overview of the EU small scale mock-up tests for ITER high heat flux components

    International Nuclear Information System (INIS)

    Vieider, G.; Barabash, V.; Cardella, A.

    1998-01-01

    This task within the EU R and D for ITER was aimed at the development of basic manufacturing solutions for the high heat flux plasma facing components such as the divertor targets, the baffles and limiters. More than 50 representative small-scale mock-ups have been manufactured with beryllium, carbon and tungsten armour using various joining technologies. High heat flux testing of 20 of these mock-ups showed the carbon mono-blocks to be the most robust solution, surviving 2000 cycles at absorbed heat fluxes of up to 24 MW m -2 . With flat armour tiles rapid joint failures occurred at 5-16 MW m -2 depending on joining technology and armour material. These test results serve as a basis for the selection of manufacturing options and materials for the prototypes now being ordered. (orig.)

  9. Definition of acceptance criteria for the ITER divertor plasma-facing components through systematic experimental analysis

    International Nuclear Information System (INIS)

    Escourbiac, F; Richou, M; Guigon, R; Durocher, A; Schlosser, J; Grosman, A; Constans, S; Merola, M; Riccardi, B

    2009-01-01

    Experience has shown that a critical part of the high-heat flux (HHF) plasma-facing component (PFC) is the armour to heat sink bond. An experimental study was performed in order to define acceptance criteria with regards to thermal hydraulics and fatigue performance of the International Thermonuclear Experimental Reactor (ITER) divertor PFCs. This study, which includes the manufacturing of samples with calibrated artificial defects relevant to the divertor design, is reported in this paper. In particular, it was concluded that defects detectable with non-destructive examination (NDE) techniques appeared to be acceptable during HHF experiments relevant to heat fluxes expected in the ITER divertor. On the basis of these results, a set of acceptance criteria was proposed and applied to the European vertical target medium-size qualification prototype: 98% of the inspected carbon fibre composite (CFC) monoblocks and 100% of tungsten (W) monoblock and flat tiles elements (i.e. 80% of the full units) were declared acceptable.

  10. Definition of acceptance criteria for the ITER divertor plasma-facing components through systematic experimental analysis

    Science.gov (United States)

    Escourbiac, F.; Richou, M.; Guigon, R.; Constans, S.; Durocher, A.; Merola, M.; Schlosser, J.; Riccardi, B.; Grosman, A.

    2009-12-01

    Experience has shown that a critical part of the high-heat flux (HHF) plasma-facing component (PFC) is the armour to heat sink bond. An experimental study was performed in order to define acceptance criteria with regards to thermal hydraulics and fatigue performance of the International Thermonuclear Experimental Reactor (ITER) divertor PFCs. This study, which includes the manufacturing of samples with calibrated artificial defects relevant to the divertor design, is reported in this paper. In particular, it was concluded that defects detectable with non-destructive examination (NDE) techniques appeared to be acceptable during HHF experiments relevant to heat fluxes expected in the ITER divertor. On the basis of these results, a set of acceptance criteria was proposed and applied to the European vertical target medium-size qualification prototype: 98% of the inspected carbon fibre composite (CFC) monoblocks and 100% of tungsten (W) monoblock and flat tiles elements (i.e. 80% of the full units) were declared acceptable.

  11. Definition of acceptance criteria for the ITER divertor plasma-facing components through systematic experimental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Escourbiac, F; Richou, M; Guigon, R; Durocher, A; Schlosser, J; Grosman, A [CEA/IRFM, F-13108, Saint-Paul-lez-Durance (France); Constans, S [AREVA-NP, Le Creusot (France); Merola, M [ITER Organization, Cadarache (France); Riccardi, B [Fusion For Energy, Barcelona (Spain)], E-mail: frederic.escourbiac@cea.fr

    2009-12-15

    Experience has shown that a critical part of the high-heat flux (HHF) plasma-facing component (PFC) is the armour to heat sink bond. An experimental study was performed in order to define acceptance criteria with regards to thermal hydraulics and fatigue performance of the International Thermonuclear Experimental Reactor (ITER) divertor PFCs. This study, which includes the manufacturing of samples with calibrated artificial defects relevant to the divertor design, is reported in this paper. In particular, it was concluded that defects detectable with non-destructive examination (NDE) techniques appeared to be acceptable during HHF experiments relevant to heat fluxes expected in the ITER divertor. On the basis of these results, a set of acceptance criteria was proposed and applied to the European vertical target medium-size qualification prototype: 98% of the inspected carbon fibre composite (CFC) monoblocks and 100% of tungsten (W) monoblock and flat tiles elements (i.e. 80% of the full units) were declared acceptable.

  12. The simple map for a single-null divertor tokamak

    International Nuclear Information System (INIS)

    Punjabi, A.; Verma, A.; Boozer, A.

    1996-01-01

    We present the simple map for a single-null divertor tokamak. The simple map is an area-preserving map based on the idea that magnetic field lines are a single-degree-of-freedom time-dependent Hamiltonian system, and that the basic features of such systems near the X-point are generic. We obtain the properties of this map and the resulting footprints of field lines on the divertor plate. These include the width of the stochastic layer, the edge safety factor, the area of the footprint and the amount of magnetic flux diverted. We give the safety factor profile, the average and median values of strike angles, lengths and the Liapunov exponents. We describe how the effects of magnetic perturbations can be included in the simple map. We show how the map can be applied to the problem of the determination of heat flux on the divertor plate in tokamaks. (Author)

  13. Material impacts and heat flux characterization of an electrothermal plasma source with an applied magnetic field

    Science.gov (United States)

    Gebhart, T. E.; Martinez-Rodriguez, R. A.; Baylor, L. R.; Rapp, J.; Winfrey, A. L.

    2017-08-01

    To produce a realistic tokamak-like plasma environment in linear plasma device, a transient source is needed to deliver heat and particle fluxes similar to those seen in an edge localized mode (ELM). ELMs in future large tokamaks will deliver heat fluxes of ˜1 GW/m2 to the divertor plasma facing components at a few Hz. An electrothermal plasma source can deliver heat fluxes of this magnitude. These sources operate in an ablative arc regime which is driven by a DC capacitive discharge. An electrothermal source was configured with two pulse lengths and tested under a solenoidal magnetic field to determine the resulting impact on liner ablation, plasma parameters, and delivered heat flux. The arc travels through and ablates a boron nitride liner and strikes a tungsten plate. The tungsten target plate is analyzed for surface damage using a scanning electron microscope.

  14. Plasma/neutral gas transport in divertors and limiters

    International Nuclear Information System (INIS)

    Gierszewski, P.J.

    1983-09-01

    The engineering design of the divertor and first wall region of fusion reactors requires accurate knowledge of the energies and particle fluxes striking these surfaces. Simple calculations indicate that approx. 10 MW/m 2 heat fluxes and approx. 1 cm/yr erosion rates are possible, but there remain fundamental physics questions that bear directly on the engineering design. The purpose of this study was to treat hydrogen plasma and neutral gas transport in divertors and pumped limiters in sufficient detail to answer some of the questions as to the actual conditions that will be expected in fusion reactors. This was accomplished in four parts: (1) a review of relevant atomic processes to establish the dominant interactions and their data base; (2) a steady-state coupled O-D model of the plasma core, scrape-off layer and divertor exhaust to determine gross modes of operation and edge conditions; (3) a 1-D kinetic transport model to investigate the case of collisionless divertor exhaust, including non-Maxwellian ions and neutral atoms, highly collisional electrons, and a self-consistent electric field; and (4) a 3-D Monte Carlo treatment of neutral transport to correctly account for geometric effects

  15. Review of the high heat flux testing as an integrated part of W7-X divertor development

    International Nuclear Information System (INIS)

    Greuner, H.; Boeswirth, B.; Boscary, J.; Friedrich, T.; Lavergne, C.; Linsmeier, Ch.; Schlosser, J.; Wiltner, A.

    2009-01-01

    The subject of the development of the WENDELSTEIN 7-X divertor is the manufacturing of approximately 900 plasma facing components (PFCs) that meet all requirements for reliable long pulse and long-term plasma operation. The actively cooled PFCs are made of CFC NB31 as plasma facing material bonded by Active Metal Casting (AMC) copper interlayer onto CuCrZr cooling structure. The pre-series activities integrated extensive high heat flux (HHF) testing to assess the industrial manufacturing. Tests were performed in the GLADIS facility under load conditions similar to those expected during operation of W7-X. The investigations focused on the improvement of fatigue resistance of the CFC/Cu bonding. The results of the last HHF test campaign demonstrated a significant enhancement of the CFC bonding quality due to the introduction of the AMC/Cu bi-layer technology. The results of the micro-chemical analyses (using EDX, AES, XPS and SIMS) of the CFC/Cu interface performed after 5000 cycles at 10 MW/m 2 confirmed its chemical stability. Far beyond the current available data about the expected lifetime of CFC-armoured PFCs, 10,000 cycles at 10 MW/m 2 were applied without any damages at the interface. The present design and manufacturing process of the tested PFCs fulfil all requirements for W7-X operation.

  16. Interpretation of ion flux and electron temperature profiles at the JET divertor target during high recycling and detached discharges

    International Nuclear Information System (INIS)

    Monk, R.D.

    1997-01-01

    Detailed experiments have been carried out with the JET Mark I pumped divertor to characterise high recycling and detached plasma regimes. This paper presents new measurements of high resolution divertor ion flux profiles that identify the growth of additional peaks during high recycling discharges. These ion flux profiles are used in conjunction with Dα and neutral flux measurements to examine the physics of divertor detachment and compare against simple analytic models. Finally, problems are highlighted with conventional methods of single and triple probe interpretation under high recycling conditions. By assuming that the single probe behaves as an asymmetric double probe the whole characteristic may be fitted and significantly lower electron temperatures may be derived when the electron to ion saturation current ratio is reduced. The results from the asymmetric double probe fit are shown to be consistent with independent diagnostic measurements. (orig.)

  17. A study of X-divertor in NSTX-U with SOLPS simulations

    Science.gov (United States)

    Chen, Zhong-Ping; Kotschenreuther, Mike; Mahajan, Swadesh; Gerhardt, Stefan

    2018-03-01

    The X-divertor (XD) geometry in NSTX-U is demonstrated, via SOLPS simulations, to perform better than the standard divertor (SD); in particular, it allows detachment at a lower upstream density and stabilizes the detachment front near the target, away from the main X-point. Consequently a stable detached operation becomes possible—the localization near the plate allows a vast reduction of heat fluxes without degrading the core plasma. Indeed, it is confirmed by our simulation that at similar states of detachment the XD outperforms the SD by reducing the heat fluxes to the target and maintaining higher upstream temperatures, resulting in scrape-off layers that are more favorable for advanced tokamak operation. These advantages are attributed to the unique geometric characteristics of XD—poloidal flaring near the target.

  18. Simulations of particle and heat fluxes in an ELMy H-mode discharge on EAST using BOUT++ code

    Science.gov (United States)

    Wu, Y. B.; Xia, T. Y.; Zhong, F. C.; Zheng, Z.; Liu, J. B.; team3, EAST

    2018-05-01

    In order to study the distribution and evolution of the transient particle and heat fluxes during edge-localized mode (ELM) bursts on the Experimental Advanced Superconducting Tokamak (EAST), the BOUT++ six-field two-fluid model is used to simulate the pedestal collapse. The profiles from the EAST H-mode discharge #56129 are used as the initial conditions. Linear analysis shows that the resistive ballooning mode and drift-Alfven wave are two dominant instabilities for the equilibrium, and play important roles in driving ELMs. The evolution of the density profile and the growing process of the heat flux at divertor targets during the burst of ELMs are reproduced. The time evolution of the poloidal structures of T e is well simulated, and the dominant mode in each stage of the ELM crash process is found. The studies show that during the nonlinear phase, the dominant mode is 5, and it changes to 0 when the nonlinear phase goes to saturation after the ELM crash. The time evolution of the radial electron heat flux, ion heat flux, and particle density flux at the outer midplane (OMP) are obtained, and the corresponding transport coefficients D r, χ ir, and χ er reach maximum around 0.3 ∼ 0.5 m2 s‑1 at ΨN = 0.9. The heat fluxes at outer target plates are several times larger than that at inner target plates, which is consistent with the experimental observations. The simulated profiles of ion saturation current density (j s) at the lower outboard (LO) divertor target are compared to those of experiments by Langmuir probes. The profiles near the strike point are similar, and the peak values of j s from simulation are very close to the measurements.

  19. Towards a physics-integrated view on divertor pumping

    International Nuclear Information System (INIS)

    Day, Chr.; Gleason-González, C.; Hauer, V.; Igitkhanov, Y.; Kalupin, D.; Varoutis, S.

    2014-01-01

    Highlights: • Physics-integrated design approaches are to be preferred over approaches based on simple requirement lists. • A physics-integrated assessment is presented for the divertor vacuum pumping system based on detachment onset conditions for the divertor. • This approach considers density dependent pump albedo to reflect the effects of gas recycling at the divertor and the changes in flow regime with density. • A comparison with DEMO indicates that the divertor pumping system for a pulsed DEMO scales less than linearly with fusion power. - Abstract: One key requirement to design the inner fuel cycle of a divertor tokamak is defined by the torus vessel gas throughput and composition, and the sub-divertor neutral pressure at which the exhaust gas has to be pumped. This paper illustrates how divertor physics aspects can be translated to requirements on the divertor vacuum pumping system. An example workflow is presented that links the realization of detachment conditions with the sub-divertor neutral gas flow patterns in order to determine the appropriate number of torus vacuum pumps. For the example case of a fusion DEMO size machine, it was found that 7 actively pumping cryopumps (ITER-type) are necessary to handle the gas throughput that is needed to manage the heat flux and densities related to detachment onset

  20. Thermal–hydraulic analysis of a candidate design for ITER divertor neutron flux monitor (DNFM)

    International Nuclear Information System (INIS)

    Tanchuk, Victor; Alexandrov, Evgeny; Batyunin, Alexander; Kashchuk, Yuri; Korban, Svetlana; Lyublin, Boris; Obudovsky, Sergey; Senik, Konstantin

    2013-01-01

    The key role in direct measurement of the ITER fusion power is assigned to the neutron diagnostic system for measurement of total neutron flux of the D–D and D–T fusion reaction with the help of a neutron flux monitor located under the divertor dome. High plasma heat loads in this position implies stringent requirements for the detector design and its cooling system to ensure the required temperature operation regime of the neutron detector. The paper describes the neutron flux monitor design developed in close collaboration with IO ITER diagnostic division. Two numerical models (hydraulic and thermal) built up to simulate the water flow in the cooling system and the temperature state of detector components are also presented and discussed. The numerical investigations carried out on the developed models have shown that only good thermal contact between the shell of the detector blocks and water-cooled casing of the monitor (fit, brazing) will provide the required temperature operation regimes of the most temperature-sensitive IFC electrodes. The obtained high temperature of the detector supports makes necessary an auxiliary direct cooling of the supports or their redesign so as to provide their higher thermal conductivity

  1. Thermal–hydraulic analysis of a candidate design for ITER divertor neutron flux monitor (DNFM)

    Energy Technology Data Exchange (ETDEWEB)

    Tanchuk, Victor, E-mail: Victor.Tanchuk@sintez.niiefa.spb.su [Scientific Technical Center SINTEZ, D.V. Efremov Institute, 196641 St. Petersburg (Russian Federation); Alexandrov, Evgeny [Institution “Project Center ITER”, 1, Akademika Kurchatova sq., 123182 Moscow (Russian Federation); Batyunin, Alexander; Kashchuk, Yuri [State Research Center of Russian Federation Troitsk Institute for Innovation and Fusion Research, ul. Pushkovykh, vladenie 12, 142190 Troitsk, Moscow Region (Russian Federation); Korban, Svetlana; Lyublin, Boris [Scientific Technical Center SINTEZ, D.V. Efremov Institute, 196641 St. Petersburg (Russian Federation); Obudovsky, Sergey [State Research Center of Russian Federation Troitsk Institute for Innovation and Fusion Research, ul. Pushkovykh, vladenie 12, 142190 Troitsk, Moscow Region (Russian Federation); Senik, Konstantin [Scientific Technical Center SINTEZ, D.V. Efremov Institute, 196641 St. Petersburg (Russian Federation)

    2013-10-15

    The key role in direct measurement of the ITER fusion power is assigned to the neutron diagnostic system for measurement of total neutron flux of the D–D and D–T fusion reaction with the help of a neutron flux monitor located under the divertor dome. High plasma heat loads in this position implies stringent requirements for the detector design and its cooling system to ensure the required temperature operation regime of the neutron detector. The paper describes the neutron flux monitor design developed in close collaboration with IO ITER diagnostic division. Two numerical models (hydraulic and thermal) built up to simulate the water flow in the cooling system and the temperature state of detector components are also presented and discussed. The numerical investigations carried out on the developed models have shown that only good thermal contact between the shell of the detector blocks and water-cooled casing of the monitor (fit, brazing) will provide the required temperature operation regimes of the most temperature-sensitive IFC electrodes. The obtained high temperature of the detector supports makes necessary an auxiliary direct cooling of the supports or their redesign so as to provide their higher thermal conductivity.

  2. Large Area Divertor Temperature Measurements Using A High-speed Camera With Near-infrared FiIters in NSTX

    International Nuclear Information System (INIS)

    Lyons, B.C.; Scotti, F.; Zweben, S.J.; Gray, T.K.; Hosea, J.; Kaita, R.; Kugel, H.W.; Maqueda, R.J.; McLean, A.G.; Roquemore, A.L.; Soukhanovskii, V.A.; Taylor, G.

    2011-01-01

    Fast cameras already installed on the National Spherical Torus Experiment (NSTX) have be equipped with near-infrared (NIR) filters in order to measure the surface temperature in the lower divertor region. Such a system provides a unique combination of high speed (> 50 kHz) and wide fi eld-of-view (> 50% of the divertor). Benchtop calibrations demonstrated the system's ability to measure thermal emission down to 330 oC. There is also, however, signi cant plasma light background in NSTX. Without improvements in background reduction, the current system is incapable of measuring signals below the background equivalent temperature (600 - 700 oC). Thermal signatures have been detected in cases of extreme divertor heating. It is observed that the divertor can reach temperatures around 800 oC when high harmonic fast wave (HHFW) heating is used. These temperature profiles were fi t using a simple heat diffusion code, providing a measurement of the heat flux to the divertor. Comparisons to other infrared thermography systems on NSTX are made.

  3. Surface heat loads on the ITER divertor vertical targets

    Czech Academy of Sciences Publication Activity Database

    Gunn, J. P.; Carpentier-Chouchana, S.; Escourbiac, F.; Hirai, T.; Panayotis, S.; Pitts, R.A.; Corre, Y.; Dejarnac, Renaud; Firdaouss, M.; Kočan, M.; Komm, Michael; Kukushkin, A.; Languille, P.; Missirlian, M.; Zhao, W.; Zhong, G.

    2017-01-01

    Roč. 57, č. 4 (2017), č. článku 046025. ISSN 0029-5515 Institutional support: RVO:61389021 Keywords : ITER * divertor * ELM heat load * inter-ELM heat load * tungsten Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 3.307, year: 2016 http://iopscience.iop.org/article/10.1088/1741-4326/aa5e2a

  4. Automated magnetic divertor design for optimal power exhaust

    Energy Technology Data Exchange (ETDEWEB)

    Blommaert, Maarten

    2017-07-01

    The so-called divertor is the standard particle and power exhaust system of nuclear fusion tokamaks. In essence, the magnetic configuration hereby 'diverts' the plasma to a specific divertor structure. The design of this divertor is still a key issue to be resolved to evolve from experimental fusion tokamaks to commercial power plants. The focus of this dissertation is on one particular design requirement: avoiding excessive heat loads on the divertor structure. The divertor design process is assisted by plasma edge transport codes that simulate the plasma and neutral particle transport in the edge of the reactor. These codes are computationally extremely demanding, not in the least due to the complex collisional processes between plasma and neutrals that lead to strong radiation sinks and macroscopic heat convection near the vessel walls. One way of improving the heat exhaust is by modifying the magnetic confinement that governs the plasma flow. In this dissertation, automated design of the magnetic configuration is pursued using adjoint based optimization methods. A simple and fast perturbation model is used to compute the magnetic field in the vacuum vessel. A stable optimal design method of the nested type is then elaborated that strictly accounts for several nonlinear design constraints and code limitations. Using appropriate cost function definitions, the heat is spread more uniformly over the high-heat load plasma-facing components in a practical design example. Furthermore, practical in-parts adjoint sensitivity calculations are presented that provide a way to an efficient optimization procedure. Results are elaborated for a fictituous JET (Joint European Torus) case. The heat load is strongly reduced by exploiting an expansion of the magnetic flux towards the solid divertor structure. Subsequently, shortcomings of the perturbation model for magnetic field calculations are discussed in comparison to a free boundary equilibrium (FBE) simulation

  5. Automated magnetic divertor design for optimal power exhaust

    International Nuclear Information System (INIS)

    Blommaert, Maarten

    2017-01-01

    The so-called divertor is the standard particle and power exhaust system of nuclear fusion tokamaks. In essence, the magnetic configuration hereby 'diverts' the plasma to a specific divertor structure. The design of this divertor is still a key issue to be resolved to evolve from experimental fusion tokamaks to commercial power plants. The focus of this dissertation is on one particular design requirement: avoiding excessive heat loads on the divertor structure. The divertor design process is assisted by plasma edge transport codes that simulate the plasma and neutral particle transport in the edge of the reactor. These codes are computationally extremely demanding, not in the least due to the complex collisional processes between plasma and neutrals that lead to strong radiation sinks and macroscopic heat convection near the vessel walls. One way of improving the heat exhaust is by modifying the magnetic confinement that governs the plasma flow. In this dissertation, automated design of the magnetic configuration is pursued using adjoint based optimization methods. A simple and fast perturbation model is used to compute the magnetic field in the vacuum vessel. A stable optimal design method of the nested type is then elaborated that strictly accounts for several nonlinear design constraints and code limitations. Using appropriate cost function definitions, the heat is spread more uniformly over the high-heat load plasma-facing components in a practical design example. Furthermore, practical in-parts adjoint sensitivity calculations are presented that provide a way to an efficient optimization procedure. Results are elaborated for a fictituous JET (Joint European Torus) case. The heat load is strongly reduced by exploiting an expansion of the magnetic flux towards the solid divertor structure. Subsequently, shortcomings of the perturbation model for magnetic field calculations are discussed in comparison to a free boundary equilibrium (FBE) simulation. These flaws

  6. Divertor erosion in DIII-D

    International Nuclear Information System (INIS)

    Whyte, D.G.; Bastasz, R.; Wampler, W.R.; Brooks, J.N.; West, W.P.; Wong, C.P.C.; Buzhinskij, O.I.; Opimach, I.V.

    1998-08-01

    Net erosion rates of carbon target plates have been measured in situ for the DIII-D lower divertor. The principal method of obtaining this data is the DiMES sample probe. Recent experiments have focused on erosion at the outer strike-point (OSP) of two divertor plasma conditions: attached (T e > 40 eV) ELMing plasmas, and detached (T e 2 . In this case, measurements and modeling agree for both gross and net carbon erosion, showing the near-surface transport and redeposition of the carbon is well understood. In the attached cases, physical sputtering (with enhancement from self-sputtering and oblique incidence) is dominant, and the effective sputtering yield, Y, is greater than 10%. In ELM-free discharges, the total OSP net erosion rate is equal to the rate of carbon accumulation in the core plasma. For the detached divertor cases, the cold incident plasma eliminates physical sputtering. Attempts to measure chemically eroded hydrocarbon molecules spectroscopically indicate an upper limit of Y ≤ 0.1% for the chemical sputtering yield. Net erosion is suppressed at the outer strike-point, which becomes a region of net redeposition (∼ 4 cm/exposure-year). The private flux wall is measured to be a region of net redeposition with dense, high neutral pressure, attached divertor plasmas. Leading edges intercepting parallel heat flux (∼ 50 MW/m 2 ) have very high net erosion rates at the OSP of an attached plasma (∼ 10 microm/s > 1,000x erosion rate of aligned surfaces). Leading edge erosion, and subsequent carbon redeposition, caused by tile gaps can account for half of the deuterium codeposition in the DIII-D divertor

  7. Progress towards RF heated steady-state plasma operations on LHD by employing ICRF heating methods and improved divertor plates

    International Nuclear Information System (INIS)

    Kumazawa, R.; Mutoh, T.; Saito, K.

    2008-10-01

    A long pulse plasma discharge experiment was carried out using RF heating power in the Large Helical Device (LHD), a currentless magnetic confining system. Progress in long pulse operation is summarized since the 10th experimental campaign (2006). A scaling relation of the plasma duration time to the applied RF power has been derived from the experimental data so far collected. It indicates that there exists a critical divertor temperature and consequently a critical RF heating power P RFcrit =0.65 MW. The area on the graph of the duration time versus the RF heating power was extended over the scaling relation by replacing divertor plates with new ones with better heat conductivity. The cause of the plasma collapse at the end of the long pulse operation was found to be the penetration of metal impurities. Many thin flakes consisting of heavy metals and graphite in stratified layers were found on the divertor plates and it was thought that they were the cause of impurity metals penetrating into the plasma. In a simulation involving injecting a graphite-coated Fe pellet to the plasma it was found that 230 Eμm in the diameter of the Fe pellet sphere was the critical size which led the plasma to collapse. A mode-conversion heating method was examined in place of the minority ICRF heating which has been employed in almost all the long-pulse plasma discharges. It was found that this method was much better from the viewpoint of achieving uniformity of the plasma heat load to the divertors. It is expected that P RFcrit will be increased by using the mode-conversion heating method. (author)

  8. 2D heat flux pattern in ASDEX upgrade L-mode with magnetic perturbation

    Energy Technology Data Exchange (ETDEWEB)

    Faitsch, Michael; Sieglin, Bernhard; Eich, Thomas; Herrmann, Albrecht; Suttrop, Wolfgang [Max-Planck-Institute for Plasma Physics, Boltzmannstr. 2, D-85748 Garching (Germany); Collaboration: the ASDEDX Upgrade Team

    2016-07-01

    A future fusion reactor is likely to operate in high confinement mode (H-mode). This mode is associated with a periodic instability at the plasma edge that expels particles and energy. This instability is called edge localized mode (ELM). External magnetic perturbation (MP) is one technique that is thought to be able to mitigate or even suppress large ELMs in next step fusion devices such as ITER, where the ELM induced heat load for unmitigated ELMs might limit the lifetime of the divertor. Applying an external magnetic perturbation breaks the axisymmetry and leads to a 2D steady state heat flux pattern at the divertor. The ASDEX Upgrade tokamak is equipped with 16 perturbation coils, 8 above (upper row) and 8 below (lower row) the outer mid plane, toroidal equally distributed. A high resolution infra red system is measuring the heat flux at the outer target at a fixed toroidal position with a resolution of around 0.6 mm. In order to measure the 2D structure a slow rotation of the MP field was applied (1 Hz) with a toroidal mode number n=2. The differential phase between the upper and lower row was changed to investigate the effect of the alignment with the field lines at the edge. The density was varied to study the density dependence of the heat transport with applied external MP and compare it to the axisymmetric scenario.

  9. ATHENA simulations of divertor pump trip and loss of heat sink transients for the GSSR

    Energy Technology Data Exchange (ETDEWEB)

    Sjoeberg, A

    2001-04-01

    The ITER-FEAT Generic Site Safety Report includes evaluations of the consequences of various types of conceivable transients that may occur during operation. The transients that have to be considered in this respect are specified in the Accident Analysis Specifications document of the safety report. For the divertor primary heat transport system the ranges of transients include amongst others a trip of the main circulation pump in the divertor cooling loop as well as a loss of heat sink, both initiated at full fusion power operation. The thermal-hydraulic consequences related to the coolability of the divertor primary heat transport system components for these two transients have been evaluated and summarized in the safety report and in the current report an overview of those efforts and associated outcome is provided. The analyses have been made with the ATHENA thermal-hydraulic code using a separately developed ATHENA model of the ITER-FEAT divertor cooling system. The results from the analyses indicate that for the pump trip transient the margin against overheating of critical highly loaded parts of the divertor cassette is small but seems sufficient. In case of the loss of heat sink transient the conservative analysis reveals that the pressurizer safety valve will be opened for an extended period of time and the long term transient development indicates a risk of completely filling up the pressurizer vessel. Thus the margins against jeopardizing the integrity of the divertor cooling system with the current design are for this case small but can for a long term operation at associate conditions pose a problem.

  10. Divertor Design and Physics Issues of Huge Power Handling for SlimCS Demo Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Asakura, N.; Hoshino, K.; Tobita, K.; Someya, Y.; Utoh, H.; Nakamura, M., E-mail: asakura.nobuyuki@jaea.go.jp [Japan Atomic Energy Agency, Rokkasho (Japan); Shimizu, K. [Japan Atomic Energy Agency, Naka (Japan); Takizuka, T. [Osaka University, Osaka (Japan)

    2012-09-15

    Full text: Power exhaust scenario for a 3 GW class fusion reactor with the ITER-size plasma has been developed with enhancing the radiation loss from seeding impurity. Transport of plasma, impurity and neutrals was simulated self-consistently, for the first time, under the Demo divertor condition using an integrated divertor simulation code SONIC. The total heat load, q{sub target}, was evaluated including radiation power load and neutral load, in addition to the plasma heat load. It was found that heat and particle diffusion coefficients significantly affect the plasma detachment. For the case of increasing the coefficients by the factor of two, peak q{sub target} is reduced from 18 MW/m{sup 2} to below the engineering design level of 10 MW/m{sup 2}, while the characteristic width of the heat flux at the midplane SOL increases slightly from 2.2 to 2.7 mm. It was also found that that enhancement of the local {chi} and D at the outer SOL affects a reduction in the peak q{sub target} near the separatrix. Effects of the divertor geometry such as the divertor leg were investigated. Outer divertor leg length was extended to 2.7 m, while the magnetic flux expansion at the target is reduced to a half compared to the reference case of 1.8 m. Large radiation volume is shifted further upstream from the target due to a reduction in T{sub e}. The peak q{sub target} decreases to 10 MW/m{sup 2} due to reduction in both the plasma heat load and the radiation power load. (author)

  11. Operation method for thermonuclear device and divertor for it

    International Nuclear Information System (INIS)

    Kotake, Michiko; Yoshioka, Ken; Fukumoto, Hideshi; Okazaki, Takashi; Kinoshita, Shigemi; Takeuchi, Kazuhiro.

    1992-01-01

    Divertor plates are disposed subsequently along with circumferential direction of a vacuum vessel in a region where magnetic fluxed generated from the divertor coils are injected toward a container wall. Each of the divertor plates is moved in a state that the injection position of the magnetic fluxes enter to the vacuum vessel is kept constant. Alternatively, each of the divertor plates is inclined at an angle facing the injection direction of plasma particle fluxes, or it is inclined so that the angle between the injection surface and the magnetic fluxes makes an acute angle. Since each of the divertor coils is moved in the state of keeping the injection position of the magnetic fluxes during firing of plasmas, in other words, with on change of the current of the divertor coils, the position of the magnetic fluxed is kept at a predetermined condition. Accordingly, charged particles are prevented from concentrating locally without causing eddy current in the coils and the vacuum vessel, which can contribute to the reduction of the wear of the divertor plates. (N.H.)

  12. Thermal Analysis of the Divertor Primary Heat Transfer System Piping During the Gas Baking Process

    International Nuclear Information System (INIS)

    Yoder, Graydon L. Jr.; Harvey, Karen; Ferrada, Juan J.

    2011-01-01

    A preliminary analysis has been performed examining the temperature distribution in the Divertor Primary Heat Transfer System (PHTS) piping and the divertor itself during the gas baking process. During gas baking, it is required that the divertor reach a temperature of 350 C. Thermal losses in the piping and from the divertor itself require that the gas supply temperature be maintained above that temperature in order to ensure that all of the divertor components reach the required temperature. The analysis described in this report was conducted in order to estimate the required supply temperature from the gas heater.

  13. Development of liquid lithium divertor for fusion reactor

    International Nuclear Information System (INIS)

    Evtihkin, V. A.; Lyublinskij, I. E.; Vertkov, A.V.; Chumanov, A.V.; Shpolyanskij, V.N.

    2000-01-01

    Development of divertor is one of the most acute problems of the tokamak fusion reactor. The use of such materials as tungsten, beryllium, graphite and CFC's enabled to solve the problem to a certain extent fulfilling the need of the ITER project. The problem still rests unsolved for the DEMO-type reactors. Lithium if used as a material for high heat flux components may provide a successful solution of the problem. A concept of Li divertor based on the use of capillary-pore structures (CPS) is proposed and is being validated by a complex of experimental research and engineering developments. An optional concept of Li divertor for power removal at 400 MW in steady-state (DEMO-S project) is presented. The complex of experimental research is under way to prove the serviceability of the Li CPS in different conditions that would be realized in divertor

  14. The study of heat flux for disruption on experimental advanced superconducting tokamak

    Science.gov (United States)

    Yang, Zhendong; Fang, Jianan; Gong, Xianzu; Gan, Kaifu; Luo, Jiarong; Zhao, Hailin; Cui, Zhixue; Zhang, Bin; Chen, Meiwen

    2016-05-01

    Disruption of the plasma is one of the most dangerous instabilities in tokamak. During the disruption, most of the plasma thermal energy is lost, which causes damages to the plasma facing components. Infrared (IR) camera is an effective tool to detect the temperature distribution on the first wall, and the energy deposited on the first wall can be calculated from the surface temperature profile measured by the IR camera. This paper concentrates on the characteristics of heat flux distribution onto the first wall under different disruptions, including the minor disruption and the vertical displacement events (VDE) disruption. Several minor disruptions have been observed before the major disruption under the high plasma density in experimental advanced superconducting tokamak. During the minor disruption, the heat fluxes are mainly deposited on the upper/lower divertors. The magnetic configuration prior to the minor disruption is a lower single null with the radial distance between the two separatrices in the outer midplane dRsep = -2 cm, while it changes to upper single null (dRsep = 1.4 cm) during the minor disruption. As for the VDE disruption, the spatial distribution of heat flux exhibits strong toroidal and radial nonuniformity, and the maximum heat flux received on the dome plate can be up to 11 MW/m2.

  15. Particle exhaust with vented structures: application to the ergodic divertor of Tore Supra

    International Nuclear Information System (INIS)

    Azeroual, A.

    2000-01-01

    In a thermonuclear reactor, one must continuously fuel the discharge and extract the ashes resulting from fusion reactions. To avoid the risk of discharge poisoning, α-particle concentration is limited to ∼ 10 %. To allow for steady-state conditions requires then to extract ≥2 % of the helium out flux. In Tore Supra, the ergodic divertor is the main component managing the heat and particle fluxes at the edge. Its principle consists in generating a resonant perturbation able to destroy magnetic surfaces at the plasma periphery. In this region, the field lines are open and connected at both ends to neutralizers which are wetted by the major part of the heat and particle fluxes and are the structures through which a part of the plasma out flux is pumped for maintaining the discharge in steady-state conditions. This work describes the neutral recirculation around the ergodic divertor and is based on a data base of 56 discharges. One discuss the two processes allowing for particle exhaust: the ballistic collection of ions and that of neutrals backscattered by atomic reactions. These two processes are modelled accounting for a realistic description of the divertor geometry. A comparison between simulations and experiments is presented for measurements characterising the three main actors of plasma-wall interaction: the edge plasma, the D α light emission and the neutral pressure in the divertor plenum. Last, one question how such a system can be extrapolated to next step machines, for which one must account for technical constraints linked to the presence of the shield protecting the coils from the high neutron flux. (author)

  16. Compatibility of detached divertor operation with robust edge pedestal performance

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, A.W., E-mail: leonard@fusion.gat.com [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Makowski, M.A.; McLean, A.G. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Osborne, T.H.; Snyder, P.B. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States)

    2015-08-15

    The compatibility of detached radiative divertor operation with a robust H-mode pedestal is examined in DIII-D. A density scan produced low temperature plasmas at the divertor target, T{sub e} ⩽ 2 eV, with high radiation leading to a factor of ⩾4 drop in peak divertor heat flux. The cold radiative plasma was confined to the divertor and did not extend across the separatrix in X-point region. A robust H-mode pedestal was maintained with a small degradation in pedestal pressure at the highest densities. The response of the pedestal pressure to increasing density is reproduced by the EPED pedestal model. However, agreement of the EPED model with experiment at high density requires an assumption of reduced diamagnetic stabilization of edge Peeling–Ballooning modes.

  17. Heat removal capability of divertor coaxial tube assembly

    International Nuclear Information System (INIS)

    Shibui, Masanao; Nakahira, Masataka; Tada, Eisuke; Takatsu, Hideyuki

    1994-05-01

    To deal with high power flowing in the divertor region, an advanced divertor concept with gas target has been proposed for use in ITER/EDA. The concept uses a divertor channel to remove the radiated power while allowing neutrals to recirculate. Candidate channel wall designs include a tube array design where many coaxial tubes are arranged in the toroidal direction to make louver. The coaxial tube consists of a Be protection tube encases many supply tubes wound helically around a return tube. V-alloy and hardened Cu-alloy have been proposed for use in the supply and return tubes. Some coolants have also been proposed for the design including pressurized He and liquid metals, because these coolants are consistent with the selection of coolants for the blanket and also meet the requirement of high temperature operation. In the coaxial tube design, the coolant area is restricted and brittle Be material is used under severe thermal cyclings. Thus, to obtain the coaxial tube with sufficient safety margin for the expected fusion power excursion, it is essential to understand its applicability limit. The paper discusses heat removal capability of the coaxial tube and recommends some design modifications. (author)

  18. A carbon-metal brazing for divertor plates in fusion devices

    International Nuclear Information System (INIS)

    Matsuda, T.; Matsumoto, T.; Miki, S.; Sogabe, T.; Okada, M.; Kubota, Y.; Sagara, A.; Noda, N.; Motojima, O.; Hino, T.; Yamashina, T.

    1993-01-01

    A divertor unit, which consists of carbon armors brazed to a copper cooling channel, is under development for fusion devices. Isotropic graphite (IG-430U) and CFC (CX-2002U) are used for the armor, and a copper for the cooling tube. A technique named as dissolution and deposit of base metal was employed for brazing. The reliability of the brazed components was evaluated both by 4-point bending test and thermal shock test. According to the results of a 4-point bending test under the temperature ranged from RT to 800 C in a vacuum, it was found that the strength of the brazed surface at RT was maintained up to the higher temperature, 600 C. High heat load test has been also performed on the brazed sample in order to find whether the samples meet the requirement of the divertor plates of LHD (Large Helical Device). Active Cooling Teststand (ACT:NIFS) with electron beam power of 100kW was used. In LHD, it is presumed that the maximum heat flux is 10MW/m 2 . In addition, the surface temperature of divertor has to be kept below 1,200 C to avoid RES, by active cooling. The heat load test showed that the brazing components of CX-2002U (flat plate type CFC-Cu brazed) was stable at 1,300 C under a heat flux of 10MW/m 2 , when the flow velocity of cooling water was 6m/s. No damage nor deterioration was found at the brazed zone after the heat load test

  19. Status of the ITER full-tungsten divertor shaping and heat load distribution analysis

    International Nuclear Information System (INIS)

    Carpentier-Chouchana, S; Hirai, T; Escourbiac, F; Durocher, A; Fedosov, A; Ferrand, L; Kocan, M; Kukushkin, A S; Jokinen, T; Komarov, V; Lehnen, M; Merola, M; Mitteau, R; Pitts, R A; Sugihara, M; Firdaouss, M; Stangeby, P C

    2014-01-01

    In September 2011, the ITER Organization (IO) proposed to begin operation with a full-tungsten (W) armoured divertor, with the objective of taking a decision on the final target material (carbon fibre composite or W) by the end of 2013. This period of 2 years would enable the development of a full-W divertor design compatible with nuclear operations, the investigation of further several physics R and D aspects associated with the use of W targets and the completion of technology qualification. Beginning with a brief overview of the reference heat load specifications which have been defined for the full-W engineering activity, this paper will report on the current status of the ITER divertor shaping and will summarize the results of related three-dimensional heat load distribution analysis performed as part of the design validation. (paper)

  20. Qualification, commissioning and in situ monitoring of high heat flux plasma facing components

    Energy Technology Data Exchange (ETDEWEB)

    Escourbiac, F. [Association Euratom-CEA, CEA/DSM/DRFC, CEA/Cadarache, F-13108 Saint Paul Lez Durance (France)], E-mail: frederic.escourbiac@cea.fr; Durocher, A.; Grosman, A.; Cismondi, F.; Courtois, X.; Farjon, J.L.; Schlosser, J. [Association Euratom-CEA, CEA/DSM/DRFC, CEA/Cadarache, F-13108 Saint Paul Lez Durance (France); Merola, M.; Tivey, R. [ITER Team, CEA/Cadarache, F-13108 Saint Paul Lez Durance (France)

    2007-10-15

    Up-to-date development of actively cooled high heat flux (HHF) plasma facing components (PFC) prototypes only allows reduced margins with regards to the ITER thermal requirements. Additionally, perfect quality cannot be ensured along series manufacturing: the presence of flaws which impair the heat transfer capability of the component, in particular at the interface armour/heat sink appears to be statistically unavoidable. In order to ensure a successful series production, a qualification methodology of actively cooled high heat flux plasma facing components is proposed. Secondly, advanced non-destructive techniques developed for HHF PFC commissioning are detailed with definition of acceptance criteria. Finally, innovative diagnostics for in situ monitoring during plasma operations or tokamak shutdowns are investigated in order to prevent immediate damage (safety monitoring); or evaluate component degradation (health monitoring). This work takes into account the relevance to Tore Supra, and is applied to W7X and ITER Divertor HHF PFC.

  1. Qualification, commissioning and in situ monitoring of high heat flux plasma facing components

    International Nuclear Information System (INIS)

    Escourbiac, F.; Durocher, A.; Grosman, A.; Cismondi, F.; Courtois, X.; Farjon, J.L.; Schlosser, J.; Merola, M.; Tivey, R.

    2007-01-01

    Up-to-date development of actively cooled high heat flux (HHF) plasma facing components (PFC) prototypes only allows reduced margins with regards to the ITER thermal requirements. Additionally, perfect quality cannot be ensured along series manufacturing: the presence of flaws which impair the heat transfer capability of the component, in particular at the interface armour/heat sink appears to be statistically unavoidable. In order to ensure a successful series production, a qualification methodology of actively cooled high heat flux plasma facing components is proposed. Secondly, advanced non-destructive techniques developed for HHF PFC commissioning are detailed with definition of acceptance criteria. Finally, innovative diagnostics for in situ monitoring during plasma operations or tokamak shutdowns are investigated in order to prevent immediate damage (safety monitoring); or evaluate component degradation (health monitoring). This work takes into account the relevance to Tore Supra, and is applied to W7X and ITER Divertor HHF PFC

  2. Driving mechanism of SOL plasma flow and effects on the divertor performance in JT-60U

    International Nuclear Information System (INIS)

    Asakura, N.; Takenaga, H.; Sakurai, S.

    2003-01-01

    The measurements of the SOL flow and plasma profiles both at the high-field-side (HFS) and low field- side (LFS), for the first time, identified the SOL flow pattern and its driving mechanism. 'Flow reversal' was found near the HFS and LFS separatrix of the main plasma for the ion ∇β drift direction towards the divertor. Radial profiles of the SOL flow were similar to those calculated numerically using the UEDGE code with the plasma drifts included although Mach numbers in measurements were greater than those obtained numerically. Particle fluxes towards the HFS and LFS divertors produced by the parallel SOL flow and E r xB drift flow were evaluated. The particle flux for the case of intense gas puff and divertor pump (puff and pump) was investigated, and it was found that both the Mach number and collisionality were enhanced, in particular, at HFS. Drift flux in the private flux region was also evaluated, and important physics issues for the divertor design and operation, such as in-out asymmetries of the heat and particle fluxes, and control of impurity ions were investigated. (author)

  3. Driving mechanism of SOL plasma flow an effects on the divertor performance in JT-60U

    International Nuclear Information System (INIS)

    Asakura, Nobuyuki; Takenaga, H.; Sakurai, S.

    2003-01-01

    The measurements of the scrape-off layer(SOL) flow and plasma profiles both at the high-field-side (HFS) and low-field-side (LFS), for the first time, identified the SOL flow pattern and its driving mechanism. 'Flow reversal' was found near the HFS and LFS separatrix of the main plasma for the ion ∇B drift direction towards the divertor, Radial profiles of the SOL flow were similar to those calculated numerically using the UEDGE code with the plasma drifts included although Mach numbers in measurements were greater than those obtained numerically. Particle fluxes towards the HFS and LFS divertors produced by the parallel SOL flow and E r xB drift flow were evaluated. The particle flux for the case of intense gas puff and divertor pump (puff and pump) was investigated, and it was found that both the Mach number and collisionality were enhanced, in particular, at HFS. Drift flux in the private flux region was also evaluated, and important physics issues for the divertor design and operation, such as in-out asymmetries of the heat and particle fluxes, and control of impurity ions were investigated. (author)

  4. Electron temperature and heat load measurements in the COMPASS divertor using the new system of probes

    Science.gov (United States)

    Adamek, J.; Seidl, J.; Horacek, J.; Komm, M.; Eich, T.; Panek, R.; Cavalier, J.; Devitre, A.; Peterka, M.; Vondracek, P.; Stöckel, J.; Sestak, D.; Grover, O.; Bilkova, P.; Böhm, P.; Varju, J.; Havranek, A.; Weinzettl, V.; Lovell, J.; Dimitrova, M.; Mitosinkova, K.; Dejarnac, R.; Hron, M.; The COMPASS Team; The EUROfusion MST1 Team

    2017-11-01

    A new system of probes was recently installed in the divertor of tokamak COMPASS in order to investigate the ELM energy density with high spatial and temporal resolution. The new system consists of two arrays of rooftop-shaped Langmuir probes (LPs) used to measure the floating potential or the ion saturation current density and one array of Ball-pen probes (BPPs) used to measure the plasma potential with a spatial resolution of ~3.5 mm. The combination of floating BPPs and LPs yields the electron temperature with microsecond temporal resolution. We report on the design of the new divertor probe arrays and first results of electron temperature profile measurements in ELMy H-mode and L-mode. We also present comparative measurements of the parallel heat flux using the new probe arrays and fast infrared termography (IR) data during L-mode with excellent agreement between both techniques using a heat power transmission coefficient γ  =  7. The ELM energy density {{\\varepsilon }\\parallel } was measured during a set of NBI assisted ELMy H-mode discharges. The peak values of {{\\varepsilon }\\parallel } were compared with those predicted by model and with experimental data from JET, AUG and MAST with a good agreement.

  5. Recent advances towards a lithium vapor box divertor

    Directory of Open Access Journals (Sweden)

    R.J. Goldston

    2017-08-01

    Full Text Available Fusion power plants are likely to require near complete detachment of the divertor plasma from the divertor target plates, in order to have both acceptable heat flux at the target to avoid prompt damage and also acceptable plasma temperature at the target surface, to minimize long-term erosion. However hydrogenic and impurity puffing experiments show that detached operation leads easily to x-point MARFEs, impure plasmas, degradation in confinement, and lower helium pressure at the exhaust. The concept of the Lithium Vapor Box Divertor is to use local evaporation and strong differential pumping through condensation to localize low-Z gas-phase material that absorbs the plasma heat flux and so achieve detachment while avoiding these difficulties. The vapor localization has been confirmed using preliminary Navier–Stokes calculations. We use ADAS calculations of εcool, the plasma energy lost per injected lithium atom, to estimate the lithium vapor pressure, and so temperature, required for detachment, taking into account power balance. We also develop a simple model of detachment to evaluate the required upstream density, based on further taking into account dynamic pressure balance. A remarkable general result is found, not just for lithium-vapor-induced detachment, that the upstream density divided by the Greenwald-limit density scales as nup/nGW ∝ (P5/8/B3/8 Tdet1/2/(εcool+γTdet, with no explicit size scaling. Tdet is the temperature just before strong pressure loss, assumed to be ∼ ½ of the ionization potential of the dominant recycling species, and γ is the sheath heat transmission factor.

  6. Time and space-resolved energy flux measurements in the divertor of the ASDEX tokamak by computerized infrared thermography

    International Nuclear Information System (INIS)

    Mueller, E.R.; Steinmetz, K.; Bein, B.K.

    1984-06-01

    A new, fully computerized and automatic thermographic system has been developed. Its two central components are an AGA THV 780 infrared camera and a PDP-11/34 computer. A combined analytical-numerical method of solving the 1-dimensional heat diffusion equation for a solid of finite thickness bounded by two parallel planes was developed. In high-density (anti nsub(e) = 8 x 10 13 cm -3 ) neutral-beam-heated (L-mode) divertor discharges in ASDEX, the power deposition on the neutralizer plates is reduced to about 10-15% of the total heating power, owing to the inelastic scattering of the divertor plasma from a neutral gas target. Between 30% and 40% of the power is missing in the global balance. The power flow inside the divertor chambers is restricted to an approximately 1-cm-thick plasma scrape-off layer. This width depends only weakly on the density and heating power. During H-phases free of Edge Localized Mode (ELM) activity the energy flow into the divertor is blocked. During H-phases with ELM activity the energy is expelled into the divertor in very short intense pulses (several MW for about one hundred μs). Sawtooth events are able to transport significant amounts of energy from the plasma core to the peripheral zones and the scrape-off layer, and they are frequently correlated with transitions from the L to the H mode. (orig./AH)

  7. Effect of low density H-mode operation on edge and divertor plasma parameters

    International Nuclear Information System (INIS)

    Maingi, R.; Mioduszewski, P.K.; Cuthbertson, J.W.

    1994-07-01

    We present a study of the impact of H-mode operation at low density on divertor plasma parameters on the DIII-D tokamak. The line-average density in H-mode was scanned by variation of the particle exhaust rate, using the recently installed divertor cryo-condensation pump. The maximum decrease (50%) in line-average electron density was accompanied by a factor of 2 increase in the edge electron temperature, and 10% and 20% reductions in the measured core and divertor radiated power, respectively. The measured total power to the inboard divertor target increased by a factor of 3, with the major contribution coming from a factor of 5 increase in the peak heat flux very close to the inner strike point. The measured increase in power at the inboard divertor target was approximately equal to the measured decrease in core and divertor radiation

  8. Discharge power dependence of carbon dust flux in a divertor simulator

    International Nuclear Information System (INIS)

    Nishiyama, Katsushi; Morita, Yasuhiko; Uchida, Giichiro; Yamashita, Daisuke; Kamataki, Kunihiro; Seo, Hyunwoong; Itagaki, Naho; Koga, Kazunori; Shiratani, Masaharu; Ashikawa, Naoko; Masuzaki, Suguru; Nishimura, Kiyohiko; Sagara, Akio; Bornholdt, Sven; Kersten, Holger

    2013-01-01

    In fusion devices, dust particles are generated due to plasma–wall interactions and may cause safety or operational problems. Therefore it is necessary to clarify the generation and transport mechanisms of dust particles. Here we have measured energy influx from H 2 plasmas toward a graphite target using a calorimetric probe and compared the results with the dust flux toward a dust collecting substrate set on the reactor wall. The dust flux decreases with increasing the energy influx. For the higher discharge power, the more number of dust particles tend to redeposit onto the graphite target due to the higher ion drag force and hence the dust flux toward the reactor wall becomes smaller. The results show that dust inventory depends strongly on energy influx to graphite divertor plates in fusion devices

  9. Electron beam irradiation experiments of monoblock divertor mock-up

    International Nuclear Information System (INIS)

    Satoh, Kazuyoshi; Akiba, Masato; Araki, Masanori; Suzuki, Satoshi; Yokoyama, Kenji; Smid, I.; Cardella, A.; Duwe, R.; Di Pietro, E.

    1993-03-01

    It is one of the key issues for ITER to develop the divertor plate. Electron beam irradiation tests were carried out on a NET divertor mock-up using JEBIS at JAERI under a collaboration between The NET team, JAERI and KFA Juelich. Screening tests (maximum heat flux of 23 MW/m 2 ) and thermal cycling tests (18 MW/m 2 , 30s, 1000cycle) were carried out. As a result of the screening tests, the erosion caused by sublimation of C/C was observed on the surface of armor tile. No serious damage such as cracks or detachments, however, were found. As a result of the thermal cycling tests, no major damage was detected on the C/C surface. However cooling time constant of the divertor mock-up increased over 600cycle. Therefore it implies that some defects would occur at the brazing interface of the divertor mock-up. (author)

  10. Particle exhaust with vented structures: application to the ergodic divertor of Tore Supra; Pompage des particules dans les tokamaks au moyen d'une structure a events: le divertor ergodique de Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Azeroual, A

    2000-04-04

    In a thermonuclear reactor, one must continuously fuel the discharge and extract the ashes resulting from fusion reactions. To avoid the risk of discharge poisoning, {alpha}-particle concentration is limited to {approx} 10 %. To allow for steady-state conditions requires then to extract {>=}2 % of the helium out flux. In Tore Supra, the ergodic divertor is the main component managing the heat and particle fluxes at the edge. Its principle consists in generating a resonant perturbation able to destroy magnetic surfaces at the plasma periphery. In this region, the field lines are open and connected at both ends to neutralizers which are wetted by the major part of the heat and particle fluxes and are the structures through which a part of the plasma out flux is pumped for maintaining the discharge in steady-state conditions. This work describes the neutral recirculation around the ergodic divertor and is based on a data base of 56 discharges. One discuss the two processes allowing for particle exhaust: the ballistic collection of ions and that of neutrals backscattered by atomic reactions. These two processes are modelled accounting for a realistic description of the divertor geometry. A comparison between simulations and experiments is presented for measurements characterising the three main actors of plasma-wall interaction: the edge plasma, the D{sub {alpha}} light emission and the neutral pressure in the divertor plenum. Last, one question how such a system can be extrapolated to next step machines, for which one must account for technical constraints linked to the presence of the shield protecting the coils from the high neutron flux. (author)

  11. Divertor plasma modification by divertor biasing and edge ergodization in JFT-2M

    International Nuclear Information System (INIS)

    Shoji, T.; Nagashima, K.; Tamai, H.; Ohdachi, S.; Miura, Y.; Ohasa, K.; Maeda, H.; Ohyabu, N.; Leonard, A.W.; Aikawa, H.; Fujita, T.; Hoshino, K.; Kawashima, H.; Matsuda, T.; Maeno, M.; Mori, M.; Ogawa, H.; Shimada, M.; Uehara, K.; Yamauchi, T.

    1995-01-01

    The effects of divertor biasing and edge ergodization on the divertor plasma have been investigated in the JFT-2M tokamak. Experimental results show; (1) The differential divertor biasing can change the in/out asymmetry of the divertor plasma. It especially changes the density on the ion side divertor plasma. The in/out electron pressure difference has a good correlation with the biasing current. (2) The unipolar divertor biasing can change the density profile of divertor plasma. The radial electric field and shear flow are the cause for this change. (3) The electron temperature of the divertor plasma in the H-mode with frequent ELMs induced by edge ergodization is lower than that of usual H-mode. That is due to the enhancement of the radial particle flux by frequent ELMs, ((orig.))

  12. Conceptual design of a divertor Thomson scattering diagnostic for NSTX-U

    Energy Technology Data Exchange (ETDEWEB)

    McLean, A. G., E-mail: mclean@fusion.gat.com; Soukhanovskii, V. A.; Allen, S. L. [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94550 (United States); Carlstrom, T. N. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); LeBlanc, B. P.; Ono, M.; Stratton, B. C. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)

    2014-11-15

    A conceptual design for a divertor Thomson scattering (DTS) diagnostic has been developed for the NSTX-U device to operate in parallel with the existing multipoint Thomson scattering system. Higher projected peak heat flux in NSTX-U will necessitate application of advanced magnetics geometries and divertor detachment. Interpretation and modeling of these divertor scenarios will depend heavily on local measurement of electron temperature, T{sub e}, and density, n{sub e}, which DTS provides in a passive manner. The DTS design for NSTX-U adopts major elements from the successful DIII-D DTS system including 7-channel polychromators measuring T{sub e} to 0.5 eV. If implemented on NSTX-U, the divertor TS system would provide an invaluable diagnostic for the boundary program to characterize the edge plasma.

  13. Development of actively cooled divertor plates for fusion experimental devices

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, M. [Mitsubishi Heavy Industries Ltd., Yokohama (Japan); Toyoda, M. [Mitsubishi Heavy Industries Ltd., Yokohama (Japan); Tsujimura, S. [Mitsubishi Heavy Industries Ltd., Yokohama (Japan); Inoue, M. [Mitsubishi Heavy Industries Ltd., Yokohama (Japan); Satoh, M. [Mitsubishi Heavy Industries Ltd., Yokohama (Japan)

    1995-12-31

    Development of high thermal resistant divertor plates using the brazing technique has been conducted. Uni-directional carbon-fiber-reinforced-carbon (CFC) has been selected as the surface material because of its high thermal conductivity and mechanical strength, while copper-alloy has been chosen as the base plate because of its high thermal conductivity. Brazing materials on CFC were examined and applied to the divertor element samples (25mm x 25mm x 35mm). Then, the samples were exposed to a high heat flux electron beam. It was found that the fabricated samples can withstand repetitive thermal shocks of 30MW/m{sup 2} x 2sec for more than 500 times. Using the developed method, two types of partial divertor models were fabricated and tested. It was shown that the models have sufficient structural integrity against thermal shocks of 9MW/m{sup 2} x 3sec-14MW/m{sup 2} x 4sec for up to 1200 times. The thermal analyses suggested that the models could withstand the steady-state heat flux of 12.6MW/m{sup 2}. In addition, the thermal stress analyses showed that the structural modification could reduce the thermal stress on the models. (orig.).

  14. Design and operation of a high-heat flux, flush-mounted ‘rail’ Langmuir probe array on Alcator C-Mod

    Directory of Open Access Journals (Sweden)

    A.Q. Kuang

    2017-08-01

    Full Text Available A poloidal array of toroidally-extended, flush-mounted ‘rail’ Langmuir probes was recently installed on Alcator C-Mod's vertical target plate divertor. The aim was to investigate if a Langmuir probe array could be designed to survive reactor-level heat fluxes and have the ability to make measurements that could be reliably interpreted under reactor-level plasma densities, neutral densities and magnetic fields. Langmuir probes are typically built to have incident field-line angles >10° to avoid interpretation issues associated with sheath expansion. However, at the high parallel heat fluxes experienced in reactor-relevant conditions such a probe would quickly overheat and melt. To mitigate both the issues of extreme heat flux and sheath expansion, each probe was designed to be flush with the divertor surface, toroidally-extended and field-aligned, giving it a ‘rail’ geometry. The flush mounted probes have proven to be exceptionally robust surviving the 2015–2016 campaign – a first for a C-Mod probe system. Examination of the probe current-voltage (I-V characteristics reveals that they are immune to sheath expansion at incident field angles down to ∼0.5°. Comparison of the flush probes to traditional proud probes shows that both measure the same electron pressure across the divertor plate. However, there are significant and systematic differences in the density, temperature and floating potential. This suggests that there is important physics, perhaps unique to conditions in a vertical-target plate divertor with small field-line attack angles, that affects the I-V characteristics and is not currently included in probe data analyses. Finally, the probe response is examined in the ‘death-ray’ regime, just near detachment. Previous work using proud probes has suggested that the ‘death-ray’ is an artefact of the probe bias. However, on flush mounted probes the ‘death-ray’ manifests itself under different conditions, which

  15. Stability and heating of a poloidal divertor tokamak

    International Nuclear Information System (INIS)

    Biddle, A.P.; Dexter, R.N.; Holly, D.T.; Lipschultz, B.; Osborne, T.H.; Prager, S.C.; Shepard, D.A.; Sprott, J.C.; Witherspoon, F.D.

    1981-01-01

    Five experimental studies - two stability and three heating investigations - have been carried out on Tokapole II, a tokamak with a four-node poloidal divertor. After a brief description of the machine, discharges are described with q approximately 0.6 over most of the cross-section without degradation of confinement, observation of axisymmetric instability in dee, inverse-dee and square equilibria, high-power fast-wave ion-cyclotron resonance heating, studies of spatial shear Alfven wave resonances for heating, and reduction of the start-up loop voltage by approximately 60% by microwave pre-ionization at electron-cyclotron resonance. Work on axisymmetric instability and studies of pre-ionization have been described in detail elsewhere and are therefore only briefly mentioned. (author)

  16. Spectroscopic diagnostics for liquid lithium divertor studies on National Spherical Torus Experiment

    International Nuclear Information System (INIS)

    Soukhanovskii, V. A.; Roquemore, A. L.; Bell, R. E.; Kaita, R.; Kugel, H. W.

    2010-01-01

    The use of lithium-coated plasma facing components for plasma density control is studied in the National Spherical Torus Experiment (NSTX). A recently installed liquid lithium divertor (LLD) module has a porous molybdenum surface, separated by a stainless steel liner from a heated copper substrate. Lithium is deposited on the LLD from two evaporators. Two new spectroscopic diagnostics are installed to study the plasma surface interactions on the LLD: (1) A 20-element absolute extreme ultraviolet (AXUV) diode array with a 6 nm bandpass filter centered at 121.6 nm (the Lyman-α transition) for spatially resolved divertor recycling rate measurements in the highly reflective LLD environment, and (2) an ultraviolet-visible-near infrared R=0.67 m imaging Czerny-Turner spectrometer for spatially resolved divertor D I, Li I-II, C I-IV, Mo I, D 2 , LiD, CD emission and ion temperature on and around the LLD module. The use of photometrically calibrated measurements together with atomic physics factors enables studies of recycling and impurity particle fluxes as functions of LLD temperature, ion flux, and divertor geometry.

  17. The study of heat flux for disruption on experimental advanced superconducting tokamak

    International Nuclear Information System (INIS)

    Yang, Zhendong; Fang, Jianan; Luo, Jiarong; Cui, Zhixue; Gong, Xianzu; Gan, Kaifu; Zhao, Hailin; Zhang, Bin; Chen, Meiwen

    2016-01-01

    Disruption of the plasma is one of the most dangerous instabilities in tokamak. During the disruption, most of the plasma thermal energy is lost, which causes damages to the plasma facing components. Infrared (IR) camera is an effective tool to detect the temperature distribution on the first wall, and the energy deposited on the first wall can be calculated from the surface temperature profile measured by the IR camera. This paper concentrates on the characteristics of heat flux distribution onto the first wall under different disruptions, including the minor disruption and the vertical displacement events (VDE) disruption. Several minor disruptions have been observed before the major disruption under the high plasma density in experimental advanced superconducting tokamak. During the minor disruption, the heat fluxes are mainly deposited on the upper/lower divertors. The magnetic configuration prior to the minor disruption is a lower single null with the radial distance between the two separatrices in the outer midplane dR_s_e_p = −2 cm, while it changes to upper single null (dR_s_e_p = 1.4 cm) during the minor disruption. As for the VDE disruption, the spatial distribution of heat flux exhibits strong toroidal and radial nonuniformity, and the maximum heat flux received on the dome plate can be up to 11 MW/m"2.

  18. Design of the Wendelstein 7-X inertially cooled Test Divertor Unit Scraper Element

    Energy Technology Data Exchange (ETDEWEB)

    Lumsdaine, Arnold, E-mail: lumsdainea@ornl.gov [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Boscary, Jean [Max Planck Institute for Plasma Physics, Garching (Germany); Fellinger, Joris [Max Planck Institute for Plasma Physics, Greifswald (Germany); Harris, Jeff [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Hölbe, Hauke; König, Ralf [Max Planck Institute for Plasma Physics, Greifswald (Germany); Lore, Jeremy; McGinnis, Dean [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Neilson, Hutch; Titus, Peter [Princeton Plasma Physics Lab, Princeton, NJ (United States); Tretter, Jörg [Max Planck Institute for Plasma Physics, Garching (Germany)

    2015-10-15

    Highlights: • The justification for the installation of the Test Divertor Unit Scraper Element is given. • Specially designed operational scenarios for the component are presented. • Plans for the design of the component are detailed. - Abstract: The Wendelstein 7-X stellarator is scheduled to begin operation in 2015, and to achieve full power steady-state operation in 2019. Computational simulations have indicated that for certain plasma configurations in the steady-state operation, the ends of the divertor targets may receive heat fluxes beyond their qualified technological limit. To address this issue, a high heat-flux “scraper element” (HHF-SE) has been designed that can protect the sensitive divertor target region. The surface profile of the HHF-SE has been carefully designed to meet challenging engineering requirements and severe spatial limitations through an iterative process involving physics simulations, engineering analysis, and computer aided design rendering. The desire to examine how the scraper element interacts with the plasma, both in terms of how it protects the divertor, and how it affects the neutral pumping efficiency, has led to the consideration of installing an inertially cooled version during the short pulse operation phase. This Test Divertor Unit Scraper Element (TDU-SE) would replicate the surface profile of the HHF-SE. The design and instrumentation of this component must be completed carefully in order to satisfy the requirements of the machine operation, as well as to support the possible installation of the HHF-SE for steady-state operation.

  19. Manufacturing and testing of a Be/OFHCCu divertor module

    Science.gov (United States)

    Araki, M.; Youchison, D. L.; Akiba, M.; Watson, R. D.; Sato, K.; Suzuki, S.

    1996-10-01

    Beryllium, carbon-based materials and tungsten are considered as plasma facing materials for the next generation of fusion machines such as the international thermonuclear experimental reactor (ITER). Beryllium is one of the primary candidate materials because of its low atomic number and lack of tritium codeposition. However, joining of a beryllium armor to a copper heat sink remains a critical problem due to the formation of brittle intermetallics at the interface. To address this concern, the Japan Atomic Energy Research Institute manufactured a beryllium/Cu divertor module with Cr and Ni diffusion barriers. This Be/Cu module was tested in the electron beam test system of Sandia National Laboratories in the framework of the US—Japan Fusion Collaboration. The divertor module consisted of four beryllium tiles, 25 mm × 25 mm, and a square copper heat sink with convolutions like a screw nut inside the coolant channel. To evaluate the integrity of the brazed bonds under various heat fluxes, beryllium tiles of two different thicknesses, 2 and 10 mm, were bonded to the copper heat sink. Cooling conditions of 10 m/s water flow velocity at 1 MPa, and a water inlet temperature of 20°C were selected based on the thermal analysis. During high heat flux testing the 10 mm thick Be tiles detached at an absorbed heat flux around 5 MW/m 2 for several shots due to flaws at the braze joint confirmed by optical observation after manufacturing. One of the 2 mm thick Be tiles failed after 550 cycles at the steady state heat flux of 6.5 MW/m 2. Most likely the failure was caused by brittleness at the interface caused by the presence of BeCu intermetallics.

  20. Manufacturing and testing of a Be/OFHC-Cu divertor module

    International Nuclear Information System (INIS)

    Araki, M.; Youchison, D.L.; Akiba, M.; Watson, R.D.; Sato, K.; Suzuki, S.

    1996-01-01

    Beryllium, carbon-based materials and tungsten are considered as plasma facing materials for the next generation of fusion machines such as the international thermonuclear experimental reactor (ITER). Beryllium is one of the primary candidate materials because of its low atomic number and lack of tritium codeposition. However, joining of a beryllium armor to a copper heat sink remains a critical problem due to the formation of brittle intermetallics at the interface. To address this concern, the Japan Atomic Energy Research Institute manufactured a beryllium/Cu divertor module with Cr and Ni diffusion barriers. This Be/Cu module was tested in the electron beam test system of Sandia National Laboratories in the framework of the US-Japan Fusion Collaboration. The divertor module consisted of four beryllium tiles, 25 mm x 25 mm, and a square copper heat sink with convolutions like a screw nut inside the coolant channel. To evaluate the integrity of the brazed bonds under various heat fluxes, beryllium tiles of two different thicknesses, 2 and 10 mm, were bonded to the copper heat sink. Cooling conditions of 10 m/s water flow velocity at 1 MPa, and a water inlet temperature of 20 C were selected based on the thermal analysis. During high heat flux testing the 10 mm thick Be tiles detached at an absorbed heat flux around 5 MW/m 2 for several shots due to flaws at the braze joint confirmed by optical observation after manufacturing. One of the 2 mm thick Be tiles failed after 550 cycles at the steady state heat flux of 6.5 MW/m 2 . Most likely the failure was caused by brittleness at the interface caused by the presence of Be-Cu intermetallics. (orig.)

  1. An experimental investigation of the post-CHF enhancement factor for a prototypical ITER divertor plate with water coolant

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, T.D. [Rensselaer Polytechnic Institute, Troy, NY (United States); Watson, R.D.; McDonald, J.M. [Sandia National Lab., Albuquerque, NM (United States)] [and others

    1995-09-01

    In an off-normal event, water-cooled copper divertor plates in the International Thermonuclear Experimental Reactor (ITER) may either experience heat loads beyond their design basis, or the normal heat loads may be accompanied by low coolant pressure and velocity. The purpose of this experiment was to illustrate that during one-sided heating, as in ITER, a copper divertor plate with the proper side wall thickness, at low system pressure and velocity can absorb without failing an incident heat flux, q{sub i}, that significantly exceed the value, q{sub i}{sup CHF}, which is associated with local CHF at the wall of the coolant channel. The experiment was performed using a 30 kW electron beam test system for heating of a square cross-section divertor heat sink with a smooth circular channel of 7.63 mm diameter. The heated width, length, and wall thickness were 16, 40, and 3 mm, respectively. Stable surface temperatures were observed at incident heat fluxes greater than the local CHF point, presumably due to circumferential conduction around the thick tube walls when q{sub i}{sup CHF} was exceeded. The Post-CHF enhancement factor, {eta}, is defined as the ratio of the incident burnout heat flux, q{sub i}{sup BO}, to q{sub i}{sup CHF}. For this experiment with water at inlet conditions of 70{degrees}C, 1 m/s, and 1 MPa, q{sub i}{sup CHF} and q{sub i}{sup BO} were 600 and 1100 W/cm{sup 2}, respectively, which gave an {eta} of 1.8.

  2. L-mode and inter-ELM divertor particle and heat flux width scaling on MAST

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, J.R., E-mail: james.harrison@ccfe.ac.uk [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Fishpool, G.M.; Kirk, A. [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2013-07-15

    The distribution of particles and power to plasma-facing components is of key importance in the design of next-generation fusion devices. Power and particle decay lengths have been measured in a number of MAST L-mode and H-mode discharges in order to determine their parametric dependencies, by fitting power and particle flux profiles measured by divertor Langmuir probes, to a convolution of an exponential decay and a Gaussian function. In all discharges analysed, it is found that exponential decay lengths mapped to the midplane are mostly dependent on separatrix electron density (n{sub e,sep}{sup 0.65±0.15}) L-mode, (n{sub e,sep}{sup 0.76±0.19}) H-mode) and plasma current (I{sub p}{sup -0.36±0.11}) L-mode, I{sub p}{sup -1.05±0.18} H-mode) (or parallel connection length). The widths of the convolved Gaussian functions have been used to derive an approximate diffusion coefficient, which is found to vary from 1 m{sup 2}/s to 7 m{sup 2}/s, and is systematically lower in H-mode compared with L-mode.

  3. Interferometric density measurements in the divertor and edge plasma regions for the additionally heated JT-60 plasmas

    International Nuclear Information System (INIS)

    Fukuda, T.; Yoshida, H.; Nagashima, A.; Ishida, S.; Kikuchi, M.; Yokomizo, H.

    1989-01-01

    The first divertor plasma density measurement and the interferometric edge plasma density measurement with boundary condition preserving millimeter waveguides were demonstrated to elucidate the mutual correlation among the divertor plasma, scrape-off layer plasma and the bulk plasma properties in the additionally heated JT-60 plasmas. The electron density in the divertor region exhibited a nonlinear dependence on the bulk plasma density for the joule-heated plasmas. When neutral beam heating is applied on the plasmas with the electron density above 2x10 19 /m 3 , however, the bulk plasma density is scraped off from the outer region to lead to density clamping, and the electron density in the divertor region rapidly increases over 1x10 20 /m 3 , from which we can deduce that the particle flow along the magnetic field is dominant, resulting in the apparent degradation of the particle confinement time. As for the case when neutral beam injection is applied to low-density plasmas, the bulk plasma electron density profile becomes flattened to yield a smaller density increase in the divertor region and no density clamping of the bulk plasma was observed. Simulation analysis which correlates the transport of the divertor plasma and the scrape-off layer plasma was also carried out to find the consistency with the experimental results. (orig.)

  4. European development of He-cooled divertors for fusion power plants

    International Nuclear Information System (INIS)

    Norajitra, P.; Giniyatulin, R.; Kuznetsov, V.; Mazul, I.; Ovchinnikov, I.; Ihli, T.; Janeschitz, G.; Krauss, W.; Kruessmann, R.; Karditsas, P.; Maisonnier, D.; Sardain, P.; Nardi, C.; Papastergiou, S.; Pizzuto, A.

    2005-01-01

    Helium-cooled divertor concepts are considered suitable for use in fusion power plants for safety reasons, as they enable the use of a coolant compatible with any blanket concept, since water would not be acceptable e.g. in connection with ceramic breeder blankets using large amounts of beryllium. Moreover, they allow for a high coolant exit temperature for increasing the efficiency of the power conversion system. Within the framework of the European power plant conceptual study (PPCS), different helium-cooled divertor concepts based on different heat transfer mechanisms are being investigated at ENEA Frascati, Italy, and Forschungszentrum Karlsruhe, Germany. They are based on a modular design which helps reduce thermal stresses. The design goal is to withstand a high heat flux of about 10-15 MW/m 2 , a value which is considered relevant to future fusion power plants to be built after ITER. The development and optimisation of the divertor concepts require an iterative design approach with analyses, studies of materials and fabrication technologies, and the execution of experiments. These issues and the state of the art of divertor development shall be the subject of this report. (author)

  5. LHD helical divertor

    International Nuclear Information System (INIS)

    Ohyabu, N.; Watanabe, T.; Ji Hantao

    1993-07-01

    The Large Helical Device (LHD) now under construction is a heliotron/torsatron device with a closed divertor system. The edge LHD magnetic structure has been studied in detail. A peculiar feature of the configuration is existence of edge surface layers, a complicated three dimensional magnetic structure which does not, however, seem to hamper the expected divertor functions. Two divertor operational modes are being considered for the LHD experiment, high density, cold radiative divertor operation as a safe heat removal scheme and high temperature divertor plasma operation. In the latter operation, a divertor plasma with temperature of a few kev, generated by efficient pumping, expects to lead to significant improvement in core plasma confinement. Conceptual designs of the LHD divertor components are under way. (author)

  6. Versator divertor experiment: preliminary designs

    International Nuclear Information System (INIS)

    Wan, A.S.; Yang, T.F.

    1984-08-01

    The emergence of magnetic divertors as an impurity control and ash removal mechanism for future tokamak reactors bring on the need for further experimental verification of the divertor merits and their ability to operate at reactor relevant conditions, such as with auxiliary heating. This paper presents preliminary designs of a bundle and a poloidal divertor for Versator II, which can operate in conjunction with the existing 150 kW of LHRF heating or LH current drive. The bundle divertor option also features a new divertor configuration which should improve the engineering and physics results of the DITE experiment. Further design optimization in both physics and engineering designs are currently under way

  7. Manufacturing and testing of a prototypical divertor vertical target for ITER

    Science.gov (United States)

    Merola, M.; Plöchl, L.; Chappuis, Ph; Escourbiac, F.; Grattarola, M.; Smid, I.; Tivey, R.; Vieider, G.

    2000-12-01

    After an extensive R&D activity, a medium-scale divertor vertical target prototype has been manufactured by the EU Home Team. This component contains all the main features of the corresponding ITER divertor design and consists of two units with one cooling channel each, assembled together and having an overall length and width of about 600 and 50 mm, respectively. The upper part of the prototype has a tungsten macro-brush armour, whereas the lower part is covered by CFC monoblocks. A number of joining techniques were required to manufacture this component as well as an appreciable effort in the development of suitable non-destructive testing methods. The component was high heat flux tested in FE200 electron beam facility at Le Creusot, France. It endured 100 cycles at 5 MW/m 2, 1000 cycles at 10 MW/m 2 and more then 1000 cycles at 15-20 MW/m 2. The final critical heat flux test reached a value in excess of 30 MW/m 2.

  8. Manufacturing and testing of reference samples for the definition of acceptance criteria for the ITER divertor

    International Nuclear Information System (INIS)

    Visca, Eliseo; Cacciotti, E.; Libera, S.; Mancini, A.; Pizzuto, A.; Roccella, S.; Riccardi, B.; Escourbiac, F.; Sanguinetti, G.P.

    2010-01-01

    The most critical part of a high heat flux (HHF) plasma facing component (PFC) is the armour to heat sink joint. An experimental study was launched by EFDA in order to define the acceptance criteria to be used for the procurements of the ITER Divertor PFCs. ENEA is involved in the European International Thermonuclear Experimental Reactor (ITER) R and D activities and together with Ansaldo Ricerche S.p.A. has manufactured several PFCs mock-ups using the Hot Radial Pressing and Pre-Brazed Casting technologies. According to the technical specifications issued by EFDA, ENEA and Ansaldo have collaborated to manufacture half of the samples with calibrated artificial defects required for this experimental study. After manufacturing, the samples were examined by ultrasonic and SATIR non-destructive examination (NDE) methods in order to confirm the size and position of the artificial defects. In particular, it was concluded that defects are detectable with these NDE techniques and they finally gave indication about the threshold of propagation during high heat flux experiments relevant with heat fluxes expected in ITER Divertor. This paper reports the manufacturing procedure used to obtain the required calibrated artificial defects in the CFC and W armoured samples as well as the NDE results and the thermal high heat flux results.

  9. Manufacturing and testing of reference samples for the definition of acceptance criteria for the ITER divertor

    Energy Technology Data Exchange (ETDEWEB)

    Visca, Eliseo, E-mail: visca@frascati.enea.i [Associazione EURATOM-ENEA sulla Fusione, Frascati (Italy); Cacciotti, E.; Libera, S.; Mancini, A.; Pizzuto, A.; Roccella, S. [Associazione EURATOM-ENEA sulla Fusione, Frascati (Italy); Riccardi, B., E-mail: Bruno.Riccardi@f4e.europa.e [Fusion For Energy, Barcelona (Spain); Escourbiac, F., E-mail: frederic.escourbiac@iter.or [ITER Organization, Cadarache (France); Sanguinetti, G.P., E-mail: gianpaolo.sanguinetti@aen.ansaldo.i [Ansaldo Energia S.p.A., Genova (Italy)

    2010-12-15

    The most critical part of a high heat flux (HHF) plasma facing component (PFC) is the armour to heat sink joint. An experimental study was launched by EFDA in order to define the acceptance criteria to be used for the procurements of the ITER Divertor PFCs. ENEA is involved in the European International Thermonuclear Experimental Reactor (ITER) R and D activities and together with Ansaldo Ricerche S.p.A. has manufactured several PFCs mock-ups using the Hot Radial Pressing and Pre-Brazed Casting technologies. According to the technical specifications issued by EFDA, ENEA and Ansaldo have collaborated to manufacture half of the samples with calibrated artificial defects required for this experimental study. After manufacturing, the samples were examined by ultrasonic and SATIR non-destructive examination (NDE) methods in order to confirm the size and position of the artificial defects. In particular, it was concluded that defects are detectable with these NDE techniques and they finally gave indication about the threshold of propagation during high heat flux experiments relevant with heat fluxes expected in ITER Divertor. This paper reports the manufacturing procedure used to obtain the required calibrated artificial defects in the CFC and W armoured samples as well as the NDE results and the thermal high heat flux results.

  10. Control of three dimensional particle flux to divertor using rotating RMP in the EAST tokamak

    Science.gov (United States)

    Jia, M.; Sun, Y.; Liang, Y.; Wang, L.; Xu, J.; Gu, S.; Lyu, B.; Wang, H. H.; Yang, X.; Zhong, F.; Chu, N.; Feng, W.; He, K.; Liu, Y. Q.; Qian, J.; Shi, T.; Shen, B.

    2018-04-01

    Controlling the steady state particle and heat flux impinging on the plasma facing components, as one of the main concerns of future fusion reactors, is still necessary when the transient power loads induced by edge localized modes (ELMs) have been eliminated by resonant magnetic perturbations (RMPs) in high confinement tokamak experiments. This is especially true for long pulse operation. One promising solution is to use the rotating perturbed field. Recently rotating and differential phase scans of n  =  1 and 2 RMP fields have been operated for the first time in EAST discharges. The particle flux patterns on the divertor targets change synchronously with both rotating and phasing RMP fields as predicted by the modeled magnetic footprint patterns. The modeling with plasma response, which is calculated by MARS-F, is also carried out. The plasma response shows amplifying or screening effect to n  =  2 perturbations with different spectra. This changes the field line penetration depth rather than the general footprint shape. This has been verified by experimental observations on EAST. These experiments motivate further study of reducing both transient and steady state local power load and particle flux with the help of rotating RMPs in long pulse operation.

  11. Innovative design for FAST divertor compatible with remote handling, electromagnetic and mechanical analyses

    Energy Technology Data Exchange (ETDEWEB)

    Di Gironimo, Giuseppe, E-mail: giuseppe.digironimo@unina.it [CREATE, University of Naples Federico II, P.le Tecchio 80, 80125 Napoli (Italy); Cacace, Maurizio [CREATE, University of Naples Federico II, P.le Tecchio 80, 80125 Napoli (Italy); Crescenzi, Fabio [ENEA, Unità Tecnica Fusione, ENEA C. R. Frascati, via E. Fermi 45, 00044 Frascati, Roma (Italy); Labate, Carmelenzo [CREATE, University of Naples Parthenope, Via Acton 38, 80133 Napoli (Italy); Lanzotti, Antonio [CREATE, University of Naples Federico II, P.le Tecchio 80, 80125 Napoli (Italy); Lucca, Flavio [LT Calcoli srl, Piazza Prinetti 26/B, 23807 Merate, LC (Italy); Marzullo, Domenico; Mozzillo, Rocco [CREATE, University of Naples Federico II, P.le Tecchio 80, 80125 Napoli (Italy); Pagani, Irene [LT Calcoli srl, Piazza Prinetti 26/B, 23807 Merate, LC (Italy); Ramogida, Giuseppe; Roccella, Selanna [ENEA, Unità Tecnica Fusione, ENEA C. R. Frascati, via E. Fermi 45, 00044 Frascati, Roma (Italy); Viganò, Fabio [LT Calcoli srl, Piazza Prinetti 26/B, 23807 Merate, LC (Italy)

    2015-10-15

    Highlights: • The conceptual design of FAST divertor has been carried out through a continuous process of requirements refinement and design optimization (V-model approach), in order to achieve a design suited to the needs, RH compatible and ITER-like. • Thermal, structural and electromagnetic analyses have been performed, resulting in requirements refinement. • FAST divertor is now characterized by more realistic, reliable and functional features, satisfying thermo-mechanical capabilities and the remote handling (RH) compatibility. - Abstract: Divertor is a crucial component in Tokamaks, aiming to exhaust the heat power and particles fluxes coming from the plasma during discharges. This paper focuses on the optimization process of FAST divertor, aimed at achieving required thermo-mechanical capabilities and the remote handling (RH) compatibility. Divertor RH system final layout has been chosen between different concept solutions proposed and analyzed within the principles of Theory of Inventive Problem Solving (TRIZ). The design was aided by kinematic simulations performed using Digital Mock-Up capabilities of Catia software. Considerable electromagnetic (EM) analysis efforts and top-down CAD approach enabled the design of a final and consistent concept, starting from a very first dimensioning for EM loads. In the final version here presented, the divertor cassette supports a set of tungsten (W) actively cooled tiles which compose the inner and outer vertical targets, facing the plasma and exhausting the main part of heat flux. W-tiles are assembled together considering a minimum gap tolerance (0.1–0.5 mm) to be mandatorily respected. Cooling channels have been re-dimensioned to optimize the geometry and the layout of coolant volume inside the cassette has been modified as well to enhance the general efficiency.

  12. Experimental complex for high flux-materials interaction research

    International Nuclear Information System (INIS)

    Gagen-Torn, V.K.; Kirillov, I.R.; Komarov, V.L.; Litunovsky, V.N.; Mazul, I.V.; Ovchinnikov, I.B.; Prokofjev, Yu.G.; Saksagansky, G.L.; Titov, V.A.

    1995-01-01

    The experimental complex for high heat flux testing of divertor materials and bumper mock-ups under conditions close to both ITER stationary and plasma disruption PFC heat loads is described. High power plasma and electron beams are using as high heat flux sources. The former are applied to disruption simulation experiments. The values of pulsed plasma heat flux load up to 110 MJ/m 2 and stationary e-beam load up to 15 MW/m 2 can obtained on these facilities. (orig.)

  13. Implications of steady-state operation on divertor design

    International Nuclear Information System (INIS)

    Sevier, D.L.; Reis, E.E.; Baxi, C.B.; Silke, G.W.; Wong, C.P.C.; Hill, D.N.

    1996-01-01

    As fusion experiments progress towards long pulse or steady state operation, plasma facing components are undergoing a significant change in their design. This change represents the transition from inertially cooled pulsed systems to steady state designs of significant power handling capacity. A limited number of Plasma Facing Component (PFC) systems are in operation or planning to address this steady state challenge at low heat flux. However in most divertor designs components are required to operate at heat fluxes at 5 MW/m 2 or above. The need for data in this area has resulted in a significant amount of thermal/hydraulic and thermal fatigue testing being done on prototypical elements. Short pulse design solutions are not adequate for longer pulse experiments and the areas of thermal design, structural design, material selection, maintainability, and lifetime prediction are undergoing significant changes. A prudent engineering approach will guide us through the transitional phase of divertor design to steady-state power plant components. This paper reviews the design implications in this transition to steady state machines and the status of the community efforts to meet evolving design requirements. 54 refs., 5 figs., 2 tabs

  14. ASDEX upgrade - definition of a tokamak experiment with a reactor compatible polaoidal divertor

    International Nuclear Information System (INIS)

    1982-03-01

    ASDEX Upgrade is intended as the next experimental step after ASDEX. It is designed to investigate the physics of a divertor tokamak as closely as possible to fusion reactor requirements, without thermonuclear heating. It is characterized by a poloidal divertor configuration with divertor coils located outside the toroidal field coils, by machine parameters which allow a line density within the plasma boundary sufficient to screen fast CX particles from the plasma core, by a scrape-off layer essentially opaque to neutrals produced at the target plates, and, finally, by an auxiliary heating power high enough for producing a reactor-like power flux density through the plasma boundary. Design considerations on the basis of physical and technical constraints yielded the tokamak system optimized with respect to effort and costs as described in the following. It uses normal-conducting coil systems, is the size of ASDEX, and has a field of 3.9 T, a plasma current of up to 1.5 MA, and a pulse duration of 10 s. To provide the required power flux density, an ICRH power of 10 MW is needed. For comparison, a superconducting version is under investigation. (orig.)

  15. Development of a full-size divertor cassette prototype for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Ulrickson, M.A. [Sandia National Labs., Albuquerque, NM (United States); Vieider, G.; Pacher, H.D. [Max-Planck-Institut fuer Plasmaphysik, Garching (Germany). NET Design Team] [and others

    1996-10-01

    Production of a full-size divertor cassette involves eight major components. All of the components are mounted on the cassette body. Inner divertor channel components for the vertical target design are being provided by the Japan Home Team. Outer divertor channel components for the vertical target design are being provided by the European and United States Home Teams. Gas box liners are being provided by the Russian Home Team. The full-size components manufactured by the four parties will be shipped to the US Home Team for assembly into a full size divertor cassette. The techniques for assembly and maintenance of the cassette will be demonstrated during this process. The assembled cassette will be tested for proper flow distribution and proof of the filling and draining procedures. The testing will include vacuum leak tightness at full temperature and pressure, cyclic heating to 150 {degrees}C, verification of dimensional accuracy of the assembled components, and application of thermal gradients to measure dimensional stability. The development of the divertor for the International Thermonuclear Experimental Reactor (ITER) depends on successful R&D efforts on materials, joining, and plasma materials interactions. Results of the development program are presented. The scale-up of the processes developed in the basic research and development tasks is accomplished by producing and high-heat-flux testing medium and full-scale mock- ups. The design of the mock-ups is discussed.

  16. Magnetic geometry and physics of advanced divertors: The X-divertor and the snowflake

    International Nuclear Information System (INIS)

    Kotschenreuther, Mike; Valanju, Prashant; Covele, Brent; Mahajan, Swadesh

    2013-01-01

    Advanced divertors are magnetic geometries where a second X-point is added in the divertor region to address the serious challenges of burning plasma power exhaust. Invoking physical arguments, numerical work, and detailed model magnetic field analysis, we investigate the magnetic field structure of advanced divertors in the physically relevant region for power exhaust—the scrape-off layer. A primary result of our analysis is the emergence of a physical “metric,” the Divertor Index DI, which quantifies the flux expansion increase as one goes from the main X-point to the strike point. It clearly separates three geometries with distinct consequences for divertor physics—the Standard Divertor (DI = 1), and two advanced geometries—the X-Divertor (XD, DI > 1) and the Snowflake (DI < 1). The XD, therefore, cannot be classified as one variant of the Snowflake. By this measure, recent National Spherical Torus Experiment and DIIID experiments are X-Divertors, not Snowflakes

  17. Magnetic geometry and physics of advanced divertors: The X-divertor and the snowflake

    Energy Technology Data Exchange (ETDEWEB)

    Kotschenreuther, Mike; Valanju, Prashant; Covele, Brent; Mahajan, Swadesh [Institute for Fusion Studies, The University of Texas at Austin, Austin, Texas 78712 (United States)

    2013-10-15

    Advanced divertors are magnetic geometries where a second X-point is added in the divertor region to address the serious challenges of burning plasma power exhaust. Invoking physical arguments, numerical work, and detailed model magnetic field analysis, we investigate the magnetic field structure of advanced divertors in the physically relevant region for power exhaust—the scrape-off layer. A primary result of our analysis is the emergence of a physical “metric,” the Divertor Index DI, which quantifies the flux expansion increase as one goes from the main X-point to the strike point. It clearly separates three geometries with distinct consequences for divertor physics—the Standard Divertor (DI = 1), and two advanced geometries—the X-Divertor (XD, DI > 1) and the Snowflake (DI < 1). The XD, therefore, cannot be classified as one variant of the Snowflake. By this measure, recent National Spherical Torus Experiment and DIIID experiments are X-Divertors, not Snowflakes.

  18. Operational limits on WEST inertial divertor sector during the early phase experiment

    Science.gov (United States)

    Firdaouss, M.; Corre, Y.; Languille, P.; Greuner, H.; Autissier, E.; Desgranges, C.; Guilhem, D.; Gunn, J. P.; Lipa, M.; Missirlian, M.; Pascal, J.-Y.; Pocheau, C.; Richou, M.; Tsitrone, E.

    2016-02-01

    The primary goal of the WEST project is to be a test bed to characterize the fatigue and lifetime of ITER-like W divertor components subjected to relevant thermal loads. During the first phase of exploitation (S2 2016), these components (W monoblock plasma facing unit—W-PFU) will be installed in conjunction with graphite components (G-PFU). Since the G-PFU will not be actively cooled, it is necessary to ensure the expected pulse duration allows the W-PFU to reach its steady state without overheating the G-PFU assembly structure or the embedded stainless-steel diagnostics. High heat flux tests were performed at the GLADIS facility to assess the thermal behavior of the G-PFU. Some operational limits based on plasma parameters were determined. It was found that it is possible to operate at an injected power such that the maximal incident heat flux on the lower divertor is 10 MW m-2 for the required pulse length.

  19. Operational limits on WEST inertial divertor sector during the early phase experiment

    International Nuclear Information System (INIS)

    Firdaouss, M; Corre, Y; Languille, P; Autissier, E; Desgranges, C; Guilhem, D; Gunn, J P; Lipa, M; Missirlian, M; Pascal, J-Y; Pocheau, C; Richou, M; Tsitrone, E; Greuner, H

    2016-01-01

    The primary goal of the WEST project is to be a test bed to characterize the fatigue and lifetime of ITER-like W divertor components subjected to relevant thermal loads. During the first phase of exploitation (S2 2016), these components (W monoblock plasma facing unit—W-PFU) will be installed in conjunction with graphite components (G-PFU). Since the G-PFU will not be actively cooled, it is necessary to ensure the expected pulse duration allows the W-PFU to reach its steady state without overheating the G-PFU assembly structure or the embedded stainless-steel diagnostics. High heat flux tests were performed at the GLADIS facility to assess the thermal behavior of the G-PFU. Some operational limits based on plasma parameters were determined. It was found that it is possible to operate at an injected power such that the maximal incident heat flux on the lower divertor is 10 MW m −2 for the required pulse length. (paper)

  20. Experimental testing and theoretical analysis of samples of a divertor plate proposed for NET

    International Nuclear Information System (INIS)

    Brossa, F.; Federici, G.; Renda, V.; Papa, L.

    1986-01-01

    This paper presents the JRC-Ispra effort to support the design of a divertor concept for future reactors. The reference frame used in this work, i.e. divertor geometry and wall loading, is that of the NET (Next European Torus) reactor, which constitutes the European collaboration in the fusion reactor technology Program. Because of its main function of plasma impurity control, the divertor is submitted to high thermal fluxes, severe sputtering rates and electromagnetic forces. The present proposal for the divertor plate is the following: 1) W-5Re for the armour; 2) Cu for the heat sink. This choice is due to the low sputtering rate and favourable high temperature mechanical properties of the W-5Re, and the high thermal conductivity of copper

  1. Stability and heating of a poloidal divertor tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Biddle, A. P.; Dexter, R. N.; Holly, D. T.; Lipschultz, B.; Osborne, T. H.; Prager, S. C.; Shepard, D.A., Sprott, J.C.; Witherspoon, F. D.

    1980-06-01

    Five experimental studies - two stability and three heating investigations - have been carried out on Tokapole II, a Tokamak with a four node poloidal divertor. First, discharges have been attained with safety factor q as low as 0.6 over most of the column without degradation of confinement, and correlation of helical instability onset with current profile shape is being studied. Second, the axisymmetric instability has been investigated in detail for various noncircular cross-sectional shapes, and results have been compared with a numerical stability code adapted to the Tokapole machine. Third, application of high power fast wave ion cyclotron resonance heating doubles the ion temperature and permits observation of heating as a function of harmonic number and spatial location of the resonance. Fourth, low power shear Alfven wave propagation is underway to test the applicability of this heating method to tokamaks. Fifth, preionization by electron cyclotron heating has been employed to reduce the startup loop voltage by approx. 60%.

  2. Facilities for technology testing of ITER divertor concepts, models, and prototypes in a plasma environment

    International Nuclear Information System (INIS)

    Cohen, S.A.

    1991-12-01

    The exhaust of power and fusion-reaction products from ITER plasma are critical physics and technology issues from performance, safety, and reliability perspectives. Because of inadequate pulse length, fluence, flux, scrape-off layer plasma temperature and density, and other parameters, the present generation of tokamaks, linear plasma devices, or energetic beam facilities are unable to perform adequate technology testing of divertor components, though they are essential contributors to many physics issues such as edge-plasma transport and disruption effects and control. This Technical Requirements Documents presents a description of the capabilities and parameters divertor test facilities should have to perform accelerated life testing on predominantly technological divertor issues such as basic divertor concepts, heat load limits, thermal fatigue, tritium inventory and erosion/redeposition. The cost effectiveness of such divertor technology testing is also discussed

  3. Divertor plate for thermonuclear reactor

    International Nuclear Information System (INIS)

    Yamazaki, Seiichiro; Sato, Keisuke; Nishio, Satoshi.

    1993-01-01

    In a divertor plate for a thermonuclear reactor, adjacent cooling pipes are electrically insulated from each other and pipes made of a gradient functional material prepared by compositing ceramics having an insulation property and metals are metallurgically joined to at least one portion of each of the cooling pipes. Electric current caused upon occurrence of plasma disruption is interrupted by the insulation portion, so that a large circuit is not formed and electromagnetic force is decreased to such a extent that the divertor plate is not ruptured. Since a header of the cooling pipes can be installed at any optional position, the installation space can be reduced. Further, since inlet and exit collection headers can be disposed on both ends of the cooling pipes, it is possible to shorten the length of the cooling pipe of the divertor plate corresponded to high heat fluxes and reduce the pressure loss on the side of coolants to about 1/2. Further, turn back portions of small radius of curvature of the cooling pipes are eliminated to reduce the cost and extend the lifetime and, in addition, protection tiles can be attached easily. (N.H.)

  4. Modeling of thermal effects on TIBER II divertor during plasma disruptions

    International Nuclear Information System (INIS)

    Bruhn, M.L.; Perkins, L.J.

    1987-01-01

    Mapping the disruption power flow from the mid-plane of the TIBER Engineering Test Reactor to its divertor and calculating the resulting thermal effects are accomplished through the modification and coupling of three presently existing computer codes. The resulting computer code TADDPAK (Thermal Analysis Divertor during Disruption PAcKage) provides three-dimensional graphic presentations of time and positional dependent thermal effects on a poloidal cross section of the double-null-divertor configured reactor. These thermal effects include incident heat flux, surface temperature, vaporization rate, total vaporization, and melting depth. The dependence of these thermal effects on material choice, disruption pulse shape, and the characteristic thickness of the plasma scrape-off layer is determined through parametric analysis with TADDPAK. This computer code is designed to be a convenient, rapid, and user-friendly modeling tool which can be easily adapted to most tokamak double-null-divertor reactor designs

  5. Technological significances to reduce the material problems. Feasibility of heat flux reduction

    International Nuclear Information System (INIS)

    Yamazaki, Seiichiro; Shimada, Michiya.

    1994-01-01

    For a divertor plate in a fusion power reactor, a high temperature coolant must be used for heat removal to keep thermal efficiency high. It makes the temperature and thermal stress of wall materials higher than the design limits. Issues of the coolant itself, e.g. burnout of high temperature water, will also become a serious problem. Sputtering erosion of the surface material will be a great concern of its lifetime. Therefore, it is necessary to reduce the heat and particle loads to the divertor plate technologically. The feasibility of some technological methods of heat reduction, such as separatrix sweeping, is discussed. As one of the most promising ideas, the methods of radiative cooling of the divertor plasma are summarized based on the recent results of large tokamaks. The feasibility of remote radiative cooling and gas divertor is discussed. The ideas are considered in recent design studies of tokamak power reactors and experimental reactors. By way of example, conceptual designs of divertor plate for the steady state tokamak power reactor are described. (author)

  6. Drift wave turbulence studies on closed and open flux surfaces: effect limiter/divertor plates location

    International Nuclear Information System (INIS)

    Ribeiro, T.; Scott, B.

    2007-01-01

    The field line connection of a tokamak sheared magnetic field has an important impact on turbulence, by ensuring a finite parallel dynamical response for every degree of freedom available in the system. This constitutes the main property which distinguishes closed from open flux surfaces in such a device. In the latter case, the poloidal periodicity of the magnetic field is replaced by a Debye sheath arising where the field lines strike the limiter/divertor plates. This is enough to break the field line connection constraint and allow the existence of convective cell modes, leading to a change in the character of the turbulence from drift wave- (closed flux surfaces) to interchange-type (open flux surfaces), and hence increasing the turbulent transport observed. Here we study the effect of changing the poloidal position of the limiter/divertor plates, using the three-dimensional electromagnetic gyrofluid turbulence code GEM, which has time dependently self consistent field aligned flux tube coordinates. For the closed flux surfaces, the globally consistent periodic boundary conditions are invoked, and for open flux surfaces a standard Debye sheath is used at the striking points. In particular, the use of two limiter positions simultaneously, top and bottom, is in order, such to allow a separation between the inboard and outboard sides of the tokamak. This highlights the differences between those two regions of the tokamak, where the curvature is either favourable (former) or unfavourable (latter), and further makes room for future experimental qualitative comparisons, for instance, on double null configurations of the tokamak ASDEX Upgrade. (author)

  7. Heat loads to divertor nearby components from secondary radiation evolved during plasma instabilities

    Energy Technology Data Exchange (ETDEWEB)

    Sizyuk, V., E-mail: vsizyuk@purdue.edu; Hassanein, A., E-mail: hassanein@purdue.edu [Center for Materials under Extreme Environment, School of Nuclear Engineering, Purdue University, West Lafayette, IN 47907 (United States)

    2015-01-15

    A fundamental issue in tokamak operation related to power exhaust during plasma instabilities is the understanding of heat and particle transport from the core plasma into the scrape-off layer and to plasma-facing materials. During abnormal and disruptive operation in tokamaks, radiation transport processes play a critical role in divertor/edge-generated plasma dynamics and are very important in determining overall lifetimes of the divertor and nearby components. This is equivalent to or greater than the effect of the direct impact of escaped core plasma on the divertor plate. We have developed and implemented comprehensive enhanced physical and numerical models in the upgraded HEIGHTS package for simulating detailed photon and particle transport in the evolved edge plasma during various instabilities. The paper describes details of a newly developed 3D Monte Carlo radiation transport model, including optimization methods of generated plasma opacities in the full range of expected photon spectra. Response of the ITER divertor's nearby surfaces due to radiation from the divertor-developed plasma was simulated by using actual full 3D reactor design and magnetic configurations. We analyzed in detail the radiation emission spectra and compared the emission of both carbon and tungsten as divertor plate materials. The integrated 3D simulation predicted unexpectedly high damage risk to the open stainless steel legs of the dome structure in the current ITER design from the intense radiation during a disruption on the tungsten divertor plate.

  8. The development of divertor and first wall armour parts at JAERI, Sandia N.L. and KFA Juelich

    International Nuclear Information System (INIS)

    Akiba, M.; Bolt, H.; Watson, R.; Kneringer, G.; Linke, J.

    1991-01-01

    The development of new armour materials, and fabrication and testings of the divertor and first wall mock-ups have worldwidely been carried out during the Conceptual Design Activites (CDA) of ITER. This paper is a review of the activities on the divertor and first wall armour components which has been performed by JAERI, Sandia National Laboratory, and KFA Juelich. The design requirements have instantly been reflected in material development. For instance, carbon fiber composites (CFCs) have already been developed to have a thermal conductivity as high as copper at room temperature. Further modification of CFC's has been made. Based on the extensive progress in armour materials, the fabrication and testings of mock-ups have been started. Divertor mock-ups which are able to endure a stationary heat flux of 8 to 15 MW/m 2 have already been developed. Some new high heat flux test facilities have been constructed and are able to simulate a heat load of plasma disruption. Extensive understanding on disruption erosion of the armour materials has been obtained by experiments with these facilities. Some mock-up tests and disruption simulating tests have been performed under international collaboration. (orig.)

  9. Some aspects of using Be as high heat flux protective armour material

    International Nuclear Information System (INIS)

    Gervash, A.; Mazul, I.; Yablokov, N.; Linke, J.

    2000-01-01

    The beryllium as plasma facing armour material must protect the actively cooled copper alloy heat sink of the First Wall and Divertor components from sputtering erosion, disruption and VDE transients and withstand the number of cycles under expected heat and neutron fluxes. The presented paper discusses some topical questions and presents recent results obtained in Russia in the frame of such consideration. In real operation beryllium as plasma facing component will be subjected to sequence of normal (cyclic heat fluxes) and off-normal (disruption, VDE) heat loads. Aiming to investigate the results of mentioned events the experiments with the number of Russian Be grades (DShG-200, TGP-56, TShG-56, TR-30, Condensed Be) as well as S-65C (ITER reference grade) at simulated disruption loads (∝5 MJ/m 2 ) and subsequent thermal cycling (∝5 MW/m 2 , 1000 cycles) were carried out. Experiments have revealed no macroscopic damage of the tested grades, although significant differences in crack formation and propagation were observed. The main statistics of performed experiments is presented and discussed. One of the main requirements to use Be as a candidate for plasma facing component is providing a reliable joint between Be and Cu-alloy heat sink structure. The unique Russian fast brazing process of joining beryllium to Cu-alloy that allows to survive high heat fluxes ≥10 MW/m 2 during thousand heating/cooling cycles without serious damaging in the armour material and its joint was described in previous works. The main goal of experiments presented in this paper was to study the high heat flux durability limit for joints as function of the pulse duration (i.e. investigation of creep/fatigue interaction). Authors present a description of the testing procedure and discuss the first results of mentioned experiments. (orig.)

  10. Mock-up test results of monoblock-type CFC divertor armor for JT-60SA

    Energy Technology Data Exchange (ETDEWEB)

    Higashijima, S. [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan)], E-mail: higashijima.satoru@jaea.go.jp; Sakurai, S.; Suzuki, S.; Yokoyama, K.; Kashiwa, Y.; Masaki, K.; Shibama, Y.K.; Takechi, M.; Shibanuma, K.; Sakasai, A.; Matsukawa, M.; Kikuchi, M. [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan)

    2009-06-15

    The JT-60 Super Advanced (JT-60SA) tokamak project starts under both the Japanese domestic program and the international program 'Broader Approach'. The maximum heat flux to JT-60SA divertor is estimated to {approx}15 MW/m{sup 2} for 100 s. Japan Atomic Energy Agency (JAEA) has developed a divertor armor facing high heat flux in the engineering R and D for ITER, and it is concluded that monoblock-type CFC divertor armor is promising for JT-60SA. The JT-60SA armor consists of CFC monoblocks, a cooling CuCrZr screw-tube, and a thin oxygen-free high conductivity copper (OFHC-Cu) buffer layer between the CFC monoblock and the screw-tube. CFC/OFHC-Cu and OFHC-Cu/CuCrZr joints are essential for the armor, and these interfaces are brazed. Needed improvements from ITER engineering R and D are good CFC/OFHC-Cu and OFHC-Cu/CuCrZr interfaces and suppression of CFC cracking. For these purposes, metalization inside CFC monoblock is applied, and we confirmed again that the mock-up has heat removal capability in excess of ITER requirement. For optimization of the fabrication method and understanding of the production yield, the mock-ups corresponding to quantity produced in one furnace at the same time is also produced, and the half of the mock-ups could remove 15 MW/m{sup 2} as required. This paper summarizes the recent progress of design and mock-up test results for JT-60SA divertor armor.

  11. Self-castellation of tungsten monoblock under high heat flux loading and impact of material properties

    OpenAIRE

    Panayotis, S.; Hirai, T.; Wirtz, Marius; Barabash, V.; Durocher, A.; Escourbiac, F.; Linke, J.; Loewenhoff, Th.; Merola, M.; Pintsuk, G.; Uytdenhouwen, I.

    2017-01-01

    In the full-tungsten divertor qualification program at ITER Organization, macro-cracks, so called self-castellation were found in a fraction of tungsten monoblocks during cyclic high heat flux loading at 20MW/m2. The number of monoblocks with macro-cracks varied with the tungsten products used as armour material. In order to understand correlation between the macro-crack appearance and W properties, an activity to characterize W monoblock materials was launched at the IO. The outcome highligh...

  12. Structural evaluation of a DTHR bundle divertor particle collector

    International Nuclear Information System (INIS)

    Prevenslik, T.V.

    1980-09-01

    The purpose of this report is to present a structural evaluation of the current bundle divertor particle collector BDPC design under a peak heat flux in relation to criteria that protect against coolant leakage into the plasma over replacement schedules planned during DTHR operation. In addition, an assessment of the BDPC structural integrity at higher heat fluxes is presented. Further, recommendations for modifications in the current BDPC design that would improve design reliability to be considered in future design studies are described. Finally, experimental test programs directed to establishing materials data necessary in providing greater confidence in subsequent structural evaluations of BDPC designs in relation to coolant leakage over planned replacement schedules are identified

  13. Non-destructive examination of the bonding interface in DEMO divertor fingers

    International Nuclear Information System (INIS)

    Richou, Marianne; Missirlian, Marc; Vignal, Nicolas; Cantone, Vincent; Hernandez, Caroline; Norajitra, Prachai; Spatafora, Luigi

    2013-01-01

    Highlights: • SATIR tests on DEMO divertor fingers (integrating or not He cooling system). • Millimeter size artificial defects were manufactured. • Detectability of millimeter size artificial defects was evaluated. • SATIR can detect defect in DEMO divertor fingers. • Simulations are well correlated to SATIR tests. -- Abstract: Plasma facing components (PFCs) with tungsten (W) armor materials for DEMO divertor require a high heat flux removal capability (at least 10 MW/m 2 in steady-state conditions). The reference divertor PFC concept is a finger with a tungsten tile as a protection and sacrificial layer brazed to a thimble made of tungsten alloy W – 1% La 2 O 3 (WL10). Defects may be located at the W thimble to W tile interface. As the number of fingers is considerable (>250,000), it is then a major issue to develop a reliable control procedure in order to control with a non-destructive examination the fabrication processes. The feasibility for detecting defect with infrared thermography SATIR test bed is presented. SATIR is based on the heat transient method and is used as an inspection tool in order to assess component heat transfer capability. SATIR tests were performed on fingers integrating or not the complex He cooling system (steel cartridge with jet holes). Millimeter size artificial defects were manufactured and their detectability was evaluated. Results of this study demonstrate that the SATIR method can be considered as a relevant non-destructive technique examination for the defect detection of DEMO divertor fingers

  14. Supply of a prototype component for the ITER divertor baffle

    International Nuclear Information System (INIS)

    Bobin-Vastra, I.; Febvre, M.; Schedler, B.; Ploechl, L.; Bouveret, Y.; Cauvin, D.; Raisson, G.; Merola, M.

    2001-01-01

    The ITER divertor baffle is one of the Plasma facing components which are developed in the frame of the ITER concept. The supply consisted in the manufacturing of four panels with four First Wall geometries using macroblock or heat sink+armour concepts. DS-Copper, and CuCrZr were the materials for the heat sink, and CFC or Tungsten Plasma spray were the armour. The panels included two Copper-based tubes each. The final purpose is the comparison of the fabricability of each type and the performances of each panel under heat fluxes

  15. Manufacturing and testing of a prototypical divertor vertical target for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Merola, M. E-mail: merolam@ipp.mpg.de; Ploechl, L.; Chappuis, Ph.; Escourbiac, F.; Grattarola, M.; Smid, I.; Tivey, R.; Vieider, G

    2000-12-01

    After an extensive R and D activity, a medium-scale divertor vertical target prototype has been manufactured by the EU Home Team. This component contains all the main features of the corresponding ITER divertor design and consists of two units with one cooling channel each, assembled together and having an overall length and width of about 600 and 50 mm, respectively. The upper part of the prototype has a tungsten macro-brush armour, whereas the lower part is covered by CFC monoblocks. A number of joining techniques were required to manufacture this component as well as an appreciable effort in the development of suitable non-destructive testing methods. The component was high heat flux tested in FE200 electron beam facility at Le Creusot, France. It endured 100 cycles at 5 MW/m{sup 2}, 1000 cycles at 10 MW/m{sup 2} and more then 1000 cycles at 15-20 MW/m{sup 2}. The final critical heat flux test reached a value in excess of 30 MW/m{sup 2}.

  16. He-cooled divertor for DEMO: Experimental verification of the conceptual modular design

    International Nuclear Information System (INIS)

    Norajitra, P.; Gervash, A.; Giniyatulin, R.; Ihli, T.; Krauss, W.; Kruessmann, R.; Kuznetsov, V.; Makhankov, A.; Mazul, I.; Ovchinnikov, I.

    2006-01-01

    A modular He-cooled divertor concept is being developed at the Forschungszentrum Karlsruhe. The design goal is to withstand a high heat flux of 10 MW/m 2 at least. The work programme of 2004 focused on experiments to verify the design and thermohydraulics layout. In cooperation with the Efremov Institute, experimental investigations were performed for the joining of tungsten parts and/or tungsten parts with steel and the fabrication of divertor components from tungsten. Moreover, gas puffing experiments were carried out with a stationary approach to measuring pressure loss and heat transfer for the purpose of screening the design options and verifying the computational fluid dynamics (CFD) calculations. The status and results of the technological and helium experiments shall be outlined in this report

  17. Development of a full-size divertor cassette prototype for ITER

    International Nuclear Information System (INIS)

    Ulrickson, M.A.; Vieider, G.; Pacher, H.D.

    1996-01-01

    Production of a full-size divertor cassette involves eight major components. All of the components are mounted on the cassette body. Inner divertor channel components for the vertical target design are being provided by the Japan Home Team. Outer divertor channel components for the vertical target design are being provided by the European and United States Home Teams. Gas box liners are being provided by the Russian Home Team. The full-size components manufactured by the four parties will be shipped to the US Home Team for assembly into a full size divertor cassette. The techniques for assembly and maintenance of the cassette will be demonstrated during this process. The assembled cassette will be tested for proper flow distribution and proof of the filling and draining procedures. The testing will include vacuum leak tightness at full temperature and pressure, cyclic heating to 150 degrees C, verification of dimensional accuracy of the assembled components, and application of thermal gradients to measure dimensional stability. The development of the divertor for the International Thermonuclear Experimental Reactor (ITER) depends on successful R ampersand D efforts on materials, joining, and plasma materials interactions. Results of the development program are presented. The scale-up of the processes developed in the basic research and development tasks is accomplished by producing and high-heat-flux testing medium and full-scale mock- ups. The design of the mock-ups is discussed

  18. Experience with high heat flux components in large tokamaks

    International Nuclear Information System (INIS)

    Chappuis, P.; Dietz, K.J.; Ulrickson, M.

    1991-01-01

    The large present day tokamaks. i.e.JET, TFTR, JT-60, DIII-D and Tore Supra are machines capable of sustaining plasma currents of several million amperes. Pulse durations range from a few seconds up to a minute. These large machines have been in operation for several years and there exists wide experience with materials for plasma facing components. Bare and coated metals, bare and coated graphites and beryllium were used for walls, limiters and divertors. High heat flux components are mainly radiation cooled, but stationary cooling for long pulse duration is also employed. This paper summarizes the experience gained in the large machines with respect to material selection, component design, problem areas, and plasma performance. 2 tabs., 26 figs., 50 refs

  19. Hydrogen recycling and transport in the helical divertor of TEXTOR

    Energy Technology Data Exchange (ETDEWEB)

    Clever, Meike

    2010-07-01

    observed. Its absence can be explained using an extended two point model including heat convection applied to the region dominated by parallel transport (laminar region). The radial penetration depth of the neutral hydrogen particles ({lambda}{sub n} {approx} 3-4 cm) estimated from spectroscopic measurements was found to be often larger than the varying radial extent of this laminar region (few mm up to 6 cm) which finally leads to convective heat transport reducing parallel temperature gradients. Increasing the radial extent of the laminar region especially in front of the divertor strike points could lead to an improvement in this respect and provide access to a high recycling regime. The radiation instability developing at high plasma densities in the helical divertor in TEXTOR is preceded by a transient partial detachment of the plasma from the divertor target plates and leads to the formation of a poloidally structured and helically inclined radiating belt, a helical divertor MARFE. While typically leading to a density limit disruption, this MARFE has been stabilised using a feedback system and could provide some divertor functionality such as low target temperature, increased neutral density and increased radiation within the stochastic boundary. Simulations using two different cross-field transport coefficients showed, that an agreement is only found at a certain level of cross-field transport (D {sub perpendicular} {sub to} =1 m{sup 2}s{sup -1}). The inclusion of carbon impurities in the simulations results in the experimentally observed reduction of the recycling flux. (orig.)

  20. Hydrogen recycling and transport in the helical divertor of TEXTOR

    International Nuclear Information System (INIS)

    Clever, Meike

    2010-01-01

    observed. Its absence can be explained using an extended two point model including heat convection applied to the region dominated by parallel transport (laminar region). The radial penetration depth of the neutral hydrogen particles (λ n ∼ 3-4 cm) estimated from spectroscopic measurements was found to be often larger than the varying radial extent of this laminar region (few mm up to 6 cm) which finally leads to convective heat transport reducing parallel temperature gradients. Increasing the radial extent of the laminar region especially in front of the divertor strike points could lead to an improvement in this respect and provide access to a high recycling regime. The radiation instability developing at high plasma densities in the helical divertor in TEXTOR is preceded by a transient partial detachment of the plasma from the divertor target plates and leads to the formation of a poloidally structured and helically inclined radiating belt, a helical divertor MARFE. While typically leading to a density limit disruption, this MARFE has been stabilised using a feedback system and could provide some divertor functionality such as low target temperature, increased neutral density and increased radiation within the stochastic boundary. Simulations using two different cross-field transport coefficients showed, that an agreement is only found at a certain level of cross-field transport (D perpendicular to =1 m 2 s -1 ). The inclusion of carbon impurities in the simulations results in the experimentally observed reduction of the recycling flux. (orig.)

  1. Active Control of Power Exhaust in Strongly Heated ASDEX Upgrade Plasmas

    Science.gov (United States)

    Dux, Ralph; Kallenbach, Arne; Bernert, Matthias; Eich, Thomas; Fuchs, Christoph; Giannone, Louis; Herrmann, Albrecht; Schweinzer, Josef; Treutterer, Wolfgang

    2012-10-01

    Due to the absence of carbon as an intrinsic low-Z radiator, and tight limits for the acceptable power load on the divertor target, ITER will rely on impurity seeding for radiative power dissipation and for generation of partial detachment. The injection of more than one radiating species is required to optimise the power removal in the main plasma and in the divertor region, i.e. a low-Z species for radiation in the divertor and a medium-Z species for radiation in the outer core plasma. In ASDEX Upgrade, a set of robust sensors, which is suitable to feedback control the radiated power in the main chamber and the divertor as well as the electron temperature at the target, has been developed. Different feedback schemes were applied in H-mode discharges with a maximum heating power of up to 23,W, i.e. at ITER values of P/R (power per major radius) to control all combinations of power flux into the divertor region, power flux onto the target or electron temperature at the target through injection of nitrogen as the divertor radiator and argon as the main chamber radiator. Even at the highest heating powers the peak heat flux density at the target is kept at benign values. The control schemes and the plasma behaviour in these discharges will be discussed.

  2. Design and analysis of the DII-D radiative divertor water-cooled structures

    International Nuclear Information System (INIS)

    Hollerbach, M.A.; Smith, J.P.; Baxi, C.B.; Bozek; Chin, E.; Phelps, R.D.; Redler, K.M.; Reis, E.E.

    1995-10-01

    The Radiative Divertor is a major modification to the divertor of DIII-D and is being designed and fabricated for installation in late 1996. The Radiative Divertor Program (RDP) will enhance the dissipative processes in the edge and divertor plasmas to reduce the heat flux and plasma erosion at the divertor target. This approach will have major implications for the heat removal methods used in future devices. The divertor is of slot-type configuration designed to minimize the flow of sputtered and injected impurities back to the core plasma. The new divertor will be composed of toroidally continuous, Inconel 625 water-cooled rings of sandwich construction with an internal water channel, incorporating seam welding to provide the water-to-vacuum seal as well as structural integrity. The divertor structure is designed to withstand electromagnetic loads as a result of halo currents and induced toroidal currents. It also accommodates the thermal differences experienced during the 400 degrees C bake used on DIII-D. A low Z plasma-facing surface is provided by mechanically attached graphite tiles. Water flow through the rings will inertially cool these tiles which will be subjected to 38 MW, 10 second pulses. Current schedules call for detailed design in 1996 with installation completed in March 1997. A full size prototype, one-quarter of one ring, is being built to validate manufacturing techniques, machining, roll-forming, and seam welding. The experience and knowledge gained through the fabrication of the prototype is discussed. The design of the electrically isolated (5 kV) vacuum-to-air water feedthroughs supplying the water-cooled rings is also discussed

  3. Design and analysis of the DIII-D radiative divertor water-cooled structures

    International Nuclear Information System (INIS)

    Hollerbach, M.A.; Smith, J.P.; Baxi, C.B.; Bozek, A.S.; Chin, E.; Phelps, R.D.; Redler, K.M.; Reis, E.E.

    1995-01-01

    The Radiative Divertor is a major modification to the divertor of DIII-D and is being designed and fabricated for installation in late 1996. The Radiative Divertor Program (RDP) will enhance the dissipative processes in the edge and divertor plasmas to reduce the heat flux and plasma erosion at the divertor target. This approach will have major implications for the heat removal methods used in future devices. The divertor is of slot-type configuration designed to minimize the flow of sputtered and injected impurities back to the core plasma. The new divertor will be composed of toroidally continuous, Inconel 625 water-cooled rings of sandwich construction with an internal water channel, incorporating seam welding to provide the water-to-vacuum seal as well as structural integrity. The divertor structure is designed to withstand electro-magnetic loads as a result of halo currents and induced toroidal currents. It also accommodates the thermal differences experienced during the 400 C bake used on DIII-D. A low Z plasma-facing surface is provided by mechanically attached graphite tiles. Water flow through the rings will inertially cool these tiles which will be subjected to 38 MW, 10 second pulses. Current schedules call for detailed design in 1996 with installation completed in March 1997. A full size prototype, one-quarter of one ring, is being built to validate manufacturing techniques, machining, roll-forming, and seam welding. The experience and knowledge gained through the fabrication of the prototype is discussed. The design of the electrically isolated (5 kV) vacuum-to-air water feedthroughs supplying the water-cooled rings is also discussed

  4. Status of R and D of the plasma facing components for the ITER divertor

    International Nuclear Information System (INIS)

    Mazul, I.V.; Akiba, M.; Arkhipov, I.

    2001-01-01

    The paper reports the progress made by the ITER Home Teams in the development of robust carbon and tungsten armoured plasma facing components for the ITER divertor. The activities on the development and study of armour materials, joining technologies, non-destructive evaluation techniques, high heat flux testing of manufactured components and neutron irradiation resistance studies are presented. The results of these activities confirm the feasibility of the main divertor components. Examples of the fruitful collaboration between Parties and future R and D needs are also described. (author)

  5. Preparation of 3D Printed Divertor Mock-up Design and Fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Won; Park, Sung Dae; Kim, Dong Jun; Kim, Suk Kwon; Lee, Eo Hwak [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The divertor for fusion reactor is known to be able to remove the extreme heat flux up to 10 MW/m2 and the various type of divertors have been developed for enhancing the heat transfer such as hypervapotron, twisted tape insertion, screwed tube, and so on. In order to overcome this limitation, 3D printing method is considered to be used in the fusion reactor divertor design in present study. With the advantages of the 3D printing, the various shapes of the inner divertor cooling tube are investigated to enhance the turbulence of coolant and to reduce the pressure drop. The metallic powder of the fusion reactor candidate material is produced as the preliminary step for using in 3D printer. The material is a reduced activation ferritic-matensitic steel named as ARAA (Advanced Reduced Activation Alloy) which have been independently developed in Korea. Gas atomization method was used to make the spherical particles with average diameter of 100 μm. Several candidates were presented to achieve the excellent heat removal capacity and the low pressure drop. Thermal-hydraulic analysis was performed to confirm the effects of the inner cooling tube geometry with a conventional CFD code, ANSYS-CFX v14.5. The modified screw type called as a rail type twisted tube was presented through the optimization process. This complicated tube could be made by 3D printing technology. (metallic powder). Thermal-hydraulic analysis was conducted to compare the 3 type geometric divertor. A rail type twisted tube has good heat transfer performance in comparison with a conventional twisted tube. The pressure drop of a rail type twisted tube was reduced about 36% compared with a conventional twisted tube.

  6. Preparation of 3D Printed Divertor Mock-up Design and Fabrication

    International Nuclear Information System (INIS)

    Lee, Dong Won; Park, Sung Dae; Kim, Dong Jun; Kim, Suk Kwon; Lee, Eo Hwak

    2016-01-01

    The divertor for fusion reactor is known to be able to remove the extreme heat flux up to 10 MW/m2 and the various type of divertors have been developed for enhancing the heat transfer such as hypervapotron, twisted tape insertion, screwed tube, and so on. In order to overcome this limitation, 3D printing method is considered to be used in the fusion reactor divertor design in present study. With the advantages of the 3D printing, the various shapes of the inner divertor cooling tube are investigated to enhance the turbulence of coolant and to reduce the pressure drop. The metallic powder of the fusion reactor candidate material is produced as the preliminary step for using in 3D printer. The material is a reduced activation ferritic-matensitic steel named as ARAA (Advanced Reduced Activation Alloy) which have been independently developed in Korea. Gas atomization method was used to make the spherical particles with average diameter of 100 μm. Several candidates were presented to achieve the excellent heat removal capacity and the low pressure drop. Thermal-hydraulic analysis was performed to confirm the effects of the inner cooling tube geometry with a conventional CFD code, ANSYS-CFX v14.5. The modified screw type called as a rail type twisted tube was presented through the optimization process. This complicated tube could be made by 3D printing technology. (metallic powder). Thermal-hydraulic analysis was conducted to compare the 3 type geometric divertor. A rail type twisted tube has good heat transfer performance in comparison with a conventional twisted tube. The pressure drop of a rail type twisted tube was reduced about 36% compared with a conventional twisted tube

  7. Effects of neutral gas collisions on the power transmission factor at the divertor sheath

    International Nuclear Information System (INIS)

    Futch, A.H.; Matthews, G.F.; Buchenauer, D.; Hill, D.N.; Jong, R.A.; Porter, G.D.

    1992-01-01

    We show that charge-exchange and other ion-neutral collision can reduce the power transmission factor of the plasma sheath, thereby lowering the ion impact energy and target plate sputtering. The power transmission factor relates the heat flux reaching the divertor target to the plasma density and temperature just in front of the surface: δ=Q surf /J ew k T e . Experimental data from the DIII-D tokamak suggests that δ could be as low as 2-3 near the region of peak divertor particle flux, instead of the 7-8 expected from usual sheath theory. Several effects combine to allow ion-neutral interactions to be important in the divertor plasma sheath. The shallow angle of incidence of the magnetic field (1-3deg in DIII-D) leads to the spatial extension of the sheath from approximately ρ i ∝1 mm normal to the plate to several centimeters along the field lines. Ionization reduces the sheath potential, and collisions reduce the ion impact energy. (orig.)

  8. Qualification test for ITER HCCR-TBS mockups with high heat flux test facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Suk-Kwon, E-mail: skkim93@kaeri.re.kr [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Seong Dae; Jin, Hyung Gon; Lee, Eo Hwak; Yoon, Jae-Sung; Lee, Dong Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2016-11-01

    Highlights: • The test mockups for ITER HCCR (Helium Cooled Ceramic Reflector) TBS (Test Blanket System) in Korea were designed and fabricated. • A thermo-hydraulic analysis was performed using a high heat flux test facility by using electron beam. • The plan for qualification tests was developed to evaluate the thermo-hydraulic efficiency in accordance with the requirements of the ITER Organization. - Abstract: The test mockups for ITER HCCR (Helium Cooled Ceramic Reflector) TBS (Test Blanket System) in Korea were designed and fabricated, and an integrity and thermo-hydraulic performance test should be completed under the same or similar operation conditions of ITER. The test plan for a thermo-hydraulic analysis was developed by using a high heat flux test facility, called the Korean heat load test facility by using electron beam (KoHLT-EB). This facility is utilized for a qualification test of the plasma facing component (PFC) for the ITER first wall and DEMO divertor, and for the thermo-hydraulic experiments. In this work, KoHLT-EB will be used for the plan of the performance qualification test of the ITER HCCR-TBS mockups. This qualification tests should be performed to evaluate the thermo-hydraulic efficiency in accordance with the requirements of the ITER Organization (IO), which describe the specifications and qualifications of the heat flux test facility and test procedure for ITER PFC.

  9. Compact poloidal divertor reference design for TNS

    International Nuclear Information System (INIS)

    Yang, T.F.; Lee, A.Y.; Ruck, G.W.; Lange, W.J.

    1977-01-01

    A compact poloidal divertor concept has been developed for TNS tokamaks and its feasibility has been demonstrated by sufficient detailed magnetic, thermal, mechanical and vacuum analyses. This particular divertor is formed by a pair of opposing coil sets which define a magnetic flux slot where the particle burial chamber is located. The magnetic flux in the space between the coil sets is compressed vertically to limit the height and to expand the horizontal width of the particle and energy burial chamber. The intensity of the poloidal field is increased to make the pitch angle of the flux lines very large so that the diverted particles can be intercepted by a large number of panels oriented at a small angle with respect to the flux lines. Large collecting surface areas can be obtained so that the thermal load and particle flux are reduced to a practical level. Flowing lithium film and solid metal panels have been considered as the particle collector and the latter is preferred. This divertor allows for most economical use of the available space inside the TF coils and thus has minor impact on the overall size of the tokamak. The divertor design is essentially independent of the tokamak system, although analyses were performed based on TNS

  10. ALPS - advanced limiter-divertor plasma-facing systems

    International Nuclear Information System (INIS)

    Allain, J. P.; Bastasz, R.; Brooks, J. N.; Evans, T.; Hassanein, A.; Luckhardt, S.; Maingi, R.; Mattas, R. F.; McCarthy, K.; Mioduszewski, P.; Mogahed, E.; Moir, R.; Molokov, S.; Morely, N.; Nygren, R.; Reed, C.; Rognlien, T.; Ruzic, D.; Sviatoslavsky, I.; Sze, D.; Tillack, M.; Ulrickson, M.; Wade, P. M.; Wong, C.; Wooley, R.

    1999-01-01

    The Advanced Limiter-divertor Plasma-facing Systems (ALPS) program was initiated in order to evaluate the potential for improved performance and lifetime for plasma-facing systems. The main goal of the program is to demonstrate the advantages of advanced limiter/divertor systems over conventional systems in terms of power density capability, component lifetime, and power conversion efficiency, while providing for safe operation and minimizing impurity concerns for the plasma. Most of the work to date has been applied to free surface liquids. A multi-disciplinary team from several institutions has been organized to address the key issues associated with these systems. The main performance goals for advanced limiters and diverters are a peak heat flux of >50 MW/m 2 ,elimination of a lifetime limit for erosion, and the ability to extract useful heat at high power conversion efficiency (approximately40%). The evaluation of various options is being conducted through a combination of laboratory experiments, modeling of key processes, and conceptual design studies. The current emphasis for the work is on the effects of free surface liquids on plasma edge performance

  11. ATHENA simulations of divertor loss of heat sink transient for the GSSR - Final report with updates

    Energy Technology Data Exchange (ETDEWEB)

    Sponton, L.L

    2001-05-01

    The ITER-FEAT Generic Site Safety Report includes evaluations of the consequences of various types of conceivable transients that can occur during operation. The transients that have to be considered in this respect are specified in the Accident Analysis Specifications document of the safety report. For the divertor primary heat transport system the ranges of transients include amongst others a loss of heat sink at full fusion power operation. The thermal-hydraulic consequences related to the coolability of the divertor primary heat transport system components for this transient have been evaluated and summarised in the safety report and in the current report an overview of those efforts and associated outcome is provided. The analyses have been made with the ATHENA thermal-hydraulic code using a separately developed ATHENA model of the ITER-FEAT divertor cooling system. In the current report results from calculations with an updated pressurizer model and pressurizer control system are outlined. The results show that the pressurizer safety valve does not open, that the pressurizer level increase is moderate and that no temperature increases jeopardize the structure integrity.

  12. ATHENA simulations of divertor loss of heat sink transient for the GSSR - Final report with updates

    International Nuclear Information System (INIS)

    Sponton, L.L.

    2001-05-01

    The ITER-FEAT Generic Site Safety Report includes evaluations of the consequences of various types of conceivable transients that can occur during operation. The transients that have to be considered in this respect are specified in the Accident Analysis Specifications document of the safety report. For the divertor primary heat transport system the ranges of transients include amongst others a loss of heat sink at full fusion power operation. The thermal-hydraulic consequences related to the coolability of the divertor primary heat transport system components for this transient have been evaluated and summarised in the safety report and in the current report an overview of those efforts and associated outcome is provided. The analyses have been made with the ATHENA thermal-hydraulic code using a separately developed ATHENA model of the ITER-FEAT divertor cooling system. In the current report results from calculations with an updated pressurizer model and pressurizer control system are outlined. The results show that the pressurizer safety valve does not open, that the pressurizer level increase is moderate and that no temperature increases jeopardize the structure integrity

  13. Probabilistic analysis of divertor plate lifetime in tokamak reactors

    International Nuclear Information System (INIS)

    Golinescu, R.P.; Kazimi, M.S.

    1994-01-01

    Defining a methodology for a reliability estimate of the International Tokamak Experimental Reactor (ITER) divertor is the objective of the study summarized in this paper. If ITER could be designed such that no transients of any type occurred, the divertor reliability would be controlled by erosion of material during normal operation. The occurrence of several transient events results in important contribution to the expected divertor failure rate. Some transients cause the temperature in the divertor plate (DP) to rise; if these temperatures get too high, the structural elements in the DP will weaken and subsequently suffer structural failure and possibly reach the melting temperature. Using the limited data available leads to the result that there is a high probability that the DP will reliably withstand a peak heat flux of 11 MW/m 2 . However, transient events will lead to a much shorter lifetime than desirable for DP's, mainly due to the expected severe effects of plasma disruptions. If transients occurred, but the shutdown mechanism succeeded to perform without inducing a disruption, divertor reliability could be significantly improved. Improved characterization of the disruption conditions, and enlarged scope of failure modes should be pursued to gain confidence in the present conclusions

  14. Cyclic heat load testing of improved CFC/Cu bonding for the W 7-X divertor targets

    International Nuclear Information System (INIS)

    Greuner, H.; Boeswirth, B.; Boscary, J.; Chaudhuri, P.; Schlosser, J.; Friedrich, T.; Plankensteiner, A.; Tivey, R.

    2009-01-01

    Extensive high heat flux cycling testing of pre-series targets was performed in the neutral beam facility GLADIS to establish the industrial process for the manufacturing of 890 targets, which will be needed for the installation of the WENDELSTEIN 7-X divertor. The targets are manufactured of flat tiles of CFC NB31 as plasma facing material bonded by an Active Metal Casting copper interlayer onto a water-cooled CuCrZr structure. Based on the results of the 3D thermo-mechanical FEM analysis of the CFC/Cu interface, an additional set of 17 full-scale pre-series elements including three design variations was manufactured by PLANSEE SE. The insertion of an additional plastically compliant copper interlayer between the cooling structure and the Active Metal Casting interlayer showed the best results. No critical tile detachment was observed during >5000 cycles at 10 MW/m 2 . These results demonstrated the sufficient life time of the component for the expected heat load in operation.

  15. Actively convected liquid metal divertor

    International Nuclear Information System (INIS)

    Shimada, Michiya; Hirooka, Yoshi

    2014-01-01

    The use of actively convected liquid metals with j × B force is proposed to facilitate heat handling by the divertor, a challenging issue associated with magnetic fusion experiments such as ITER. This issue will be aggravated even more for DEMO and power reactors because the divertor heat load will be significantly higher and yet the use of copper would not be allowed as the heat sink material. Instead, reduced activation ferritic/martensitic steel alloys with heat conductivities substantially lower than that of copper, will be used as the structural materials. The present proposal is to fill the lower part of the vacuum vessel with liquid metals with relatively low melting points and low chemical activities including Ga and Sn. The divertor modules, equipped with electrodes and cooling tubes, are immersed in the liquid metal. The electrode, placed in the middle of the liquid metal, can be biased positively or negatively with respect to the module. The j × B force due to the current between the electrode and the module provides a rotating motion for the liquid metal around the electrodes. The rise in liquid temperature at the separatrix hit point can be maintained at acceptable levels from the operation point of view. As the rotation speed increases, the current in the liquid metal is expected to decrease due to the v × B electromotive force. This rotating motion in the poloidal plane will reduce the divertor heat load significantly. Another important benefit of the convected liquid metal divertor is the fast recovery from unmitigated disruptions. Also, the liquid metal divertor concept eliminates the erosion problem. (letter)

  16. Activation of TZM and stainless steel divertor materials in the NET fusion machine

    International Nuclear Information System (INIS)

    Cepraga, D.G.; Menapace, E.; Cambi, G.; Ciattaglia, S.; Petrizzi, L.; Cavallone, G.; Costa, M.; Broccoli, U.

    1994-01-01

    This paper presents the results of the activation and decay heat calculations for the divertor plate materials of the Next European Torus (NET). The basic option assessed enables molybdenum alloy TZM and AISI 316L as material for divertor cooling channels. Burn time, effective irradiation time history, and fluence dependence on activation, decay heat, and contact dose is assessed. Impact of the material impurity level on the radioactive inventory is also investigated. The ANITA code is used, with updated cross sections and decay data libraries based on EFF-2 and EAF-3 evaluation files. The flux-weighted spectrum provided by XSDRNPM or ANISN 1-D codes has been used. The real NET geometry was modelled with the 3-D MCNP Monte Carlo neutron transport code. ((orig.))

  17. Activation of TZM and stainless steel divertor materials in the NET fusion machine

    Energy Technology Data Exchange (ETDEWEB)

    Cepraga, D G [ENEA, INN-FIS, 8 Viale Ercolani, 40138, Bologna (Italy); Menapace, E [ENEA, INN-FIS, 8 Viale Ercolani, 40138, Bologna (Italy); Cambi, G [Bologna University, Physics Department, 33 Via Irnerio, 40126, Bologna (Italy); Ciattaglia, S [ENEA, NUC-FUS, 27 Via E. Fermi, 00044, Frascati (Italy); Petrizzi, L [ENEA, NUC-FUS, 27 Via E. Fermi, 00044, Frascati (Italy); Cavallone, G [NIER S.r.l., 16 Via S. Stefano, 40125, Bologna (Italy); Costa, M [NIER S.r.l., 16 Via S. Stefano, 40125, Bologna (Italy); Broccoli, U [ENEA, NUC-RIN, 4 Via Martiri del Sole, 40100, Bologna (Italy)

    1994-09-01

    This paper presents the results of the activation and decay heat calculations for the divertor plate materials of the Next European Torus (NET). The basic option assessed enables molybdenum alloy TZM and AISI 316L as material for divertor cooling channels. Burn time, effective irradiation time history, and fluence dependence on activation, decay heat, and contact dose is assessed. Impact of the material impurity level on the radioactive inventory is also investigated. The ANITA code is used, with updated cross sections and decay data libraries based on EFF-2 and EAF-3 evaluation files. The flux-weighted spectrum provided by XSDRNPM or ANISN 1-D codes has been used. The real NET geometry was modelled with the 3-D MCNP Monte Carlo neutron transport code. ((orig.))

  18. TCV divertor upgrade for alternative magnetic configurations

    Directory of Open Access Journals (Sweden)

    H. Reimerdes

    2017-08-01

    Full Text Available The Swiss Plasma Center (SPC is planning a divertor upgrade for the TCV tokamak. The upgrade aims at extending the research of conventional and alternative divertor configurations to operational scenarios and divertor regimes of greater relevance for a fusion reactor. The main elements of the upgrade are the installation of an in-vessel structure to form a divertor chamber of variable closure and enhanced diagnostic capabilities, an increase of the pumping capability of the divertor chamber and the addition of new divertor poloidal field coils. The project follows a staged approach and is carried out in parallel with an upgrade of the TCV heating system. First calculations using the EMC3-Eirene code indicate that realistic baffles together with the planned heating upgrade will allow for a significantly higher compression of neutral particles in the divertor, which is a prerequisite to test the power dissipation potential of various divertor configurations.

  19. Divertors for helical devices: Concepts, plans, results and problems

    International Nuclear Information System (INIS)

    Koenig, R.; Grigull, P.; McCormick, K.

    2003-01-01

    With LHD and W7-X stellarator development is now taking a large leap forward on the path to a steady-state fusion reactor. Important issues that need to be settled in these machines are particle flux and heat control, and the impact of divertors on plasma performance in future continuously burning fusion plasmas. The divertor concepts that will initially be explored in these large stellarators were carefully prepared in smaller scale devices like Heliotron E, CHS and W7-AS. While advanced divertor scenarios relevant for W7-X were already studied in W7-AS, other smaller scale experiments like Heliotron-J, CHS and NCSX will be used for the further development of divertor concepts. The two divertor configurations that are presently being investigated, are the helical and the island divertor, as well as the local island divertor (LID), which was successfully demonstrated on CHS and just went into operation on LHD. Presently, on its route to a fully closed helical divertor, LHD operates in an open helical divertor configuration. W7-X will be equipped right from the start with an actively cooled discrete island divertor which will allow quasi continuous operation. The divertor design is very similar to the one explored on W7-AS. For sufficiently large island sizes and not too long field line connection lengths, this divertor gives access to a partially detached quasi steady-state operating scenario in a newly found high density H-mode operating regime, which benefits from high energy and extremely low impurity confinement times, with edge radiation levels of up to 90 % and sufficient neutral compression in the subdivertor region (> 10) for active pumping. The basic physics of the different divertor concepts and associated implementation problems, like asymmetries due to drifts, accessibility of essential operating scenarios and toroidal asymmetries due to symmetry breaking error fields, etc. will be discussed. (orig.)

  20. Divertors for Helical Devices: Concepts, Plans, Results, and Problems

    International Nuclear Information System (INIS)

    Koenig, R.; Grigull, P.; McCormick, K.

    2004-01-01

    With Large Helical Device (LHD) and Wendelstein 7-X (W7-X), the development of helical devices is now taking a large step forward on the path to a steady-state fusion reactor. Important issues that need to be settled in these machines are particle flux and heat control and the impact of divertors on plasma performance in future continuously burning fusion plasmas. The divertor concepts that will initially be explored in these large machines were prepared in smaller-scale devices like Heliotron E, Compact Helical System (CHS), and Wendelstein 7-AS (W7-AS). While advanced divertor scenarios relevant for W7-X were already studied in W7-AS, other smaller-scale experiments like Heliotron-J, CHS, and National Compact Stellarator Experiment will be used for the further development of divertor concepts. The two divertor configurations that are being investigated are the helical and the island divertor, as well as the local island divertor, which was successfully demonstrated on CHS and just went into operation on LHD. At present, on its route to a fully closed helical divertor, LHD operates in an open helical divertor configuration. W7-X will be equipped right from the start with an actively cooled discrete island divertor that will allow quasi-continuous operation. The divertor design is very similar to the one explored on W7-AS. For sufficiently large island sizes and not too long field line connection lengths, this divertor gives access to a partially detached quasi-steady-state operating scenario in a newly found high-density H-mode operating regime, which benefits from high energy and low impurity confinement times, with edge radiation levels of up to 90% and sufficient neutral compression in the subdivertor region (>10) for active pumping. The basic physics of the different divertor concepts and associated implementation problems, like asymmetries due to drifts, accessibility of essential operating scenarios, toroidal asymmetries due to symmetry breaking error fields

  1. Optimal thermal-hydraulic performance for helium-cooled divertors

    International Nuclear Information System (INIS)

    Izenson, M.G.; Martin, J.L.

    1996-01-01

    Normal flow heat exchanger (NFHX) technology offers the potential for cooling divertor panels with reduced pressure drops (<0.5% Δp/p), reduced pumping power (<0.75% pumping/thermal power), and smaller duct sizes than conventional helium heat exchangers. Furthermore, the NFHX can easily be fabricated in the large sizes required for divertors in large tokamaks. Recent experimental and computational results from a program to develop NFHX technology for divertor coolings using porous metal heat transfer media are described. We have tested the thermal and flow characteristics of porous metals and identified the optimal heat transfer material for the divertor heat exchanger. Methods have been developed to create highly conductive thermal bonds between the porous material and a solid substrate. Computational fluid dynamics calculations of flow and heat transfer in the porous metal layer have shown the capability of high thermal effectiveness. An 18-kW NFHX, designed to meet specifications for the international Thermonuclear Experimental Reactor divertor, has been fabricated and tested for thermal and flow performance. Preliminary results confirm design and fabrication methods. 11 refs., 12 figs., 1 tab

  2. Theory and Simulations of ELM Control with a Snowflake Divertor

    Energy Technology Data Exchange (ETDEWEB)

    Ryutov, D.; Cohen, B.; Cohen, R.; Makowski, M. A.; Menard, J.; Rognlien, T.; Soukhanovskii, V.; Umansky, M.; Xu, X., E-mail: ryutov1@llnl.gov [Lawrence Livermore National Laboratory, Livermore (United States); Kolemen, E. [Princeton Plasma Physics Laboratory, Princeton (United States)

    2012-09-15

    Full text: This paper is concerned with the use of a snowflake (SF) divertor for the control and mitigation of edge localized modes (ELMs). Our research is focused on the following three issues: 1. Effect of the SF geometry on neoclassical ion orbits near the separatrix, including prompt ion losses and the related control mechanism for the electric field and plasma flow in the pedestal; 2. Influence of the thereby modified flow and of high poloidal plasma beta in the divertor region on plasma turbulence and transport in the snowflake-plus geometry; 3. Reaction of the SF divertor to type-1 ELM events. Neoclassical ion orbits in the vicinity of the SF separatrix are changed due to a much weaker poloidal field near the null and much longer particle dwell-time in this area. This leads to an increase of the prompt ion loss, which then affects the radial electric field profile near the separatrix. The resulting E x B flow shear in the pedestal region affects the onset of ELMs. The electric field and velocity shear are then used as a background for two-fluid simulations of the edge plasma turbulence in a realistic geometry with the 3D BOUT code. A SF-plus geometry is chosen, so that the separatrix topology remains the same as for the standard X-point divertor, whereas the magnetic shear both inside and outside the separatrix increases dramatically. It is found that mesoscale instabilities are suppressed when the geometry is close to a perfect SF. In situations where complete suppression of ELMs is impossible, the SF divertor offers a path to reducing heat loads during ELM events to an acceptable level. Two effects, both related to the weakness of the poloidal field near the SF null, act synergistically in the same favorable direction. The first is the onset of strong, curvature-driven convection in the divertor, triggered by the increase of the poloidal pressure during the ELM and leading to the splitting of the heat flux between all four (as is the case in a SF geometry

  3. Narrow power deposition profiles on the JET divertor target

    International Nuclear Information System (INIS)

    Lingertat, J.; Laux, M.; Monk, R.

    2001-01-01

    One of the key unresolved issues in the design of a future fusion reactor is the power handling capability of the divertor target plates. Earlier we reported on the existence of narrow power deposition profiles in JET, obtained mainly from Langmuir probe measurements. We repeated these measurements in the MkI, MkII and MkIIGB divertor configurations with an upgraded probe system, which allowed us to study the profile shape in more detail. The main results of this study are: In NB heated discharges the electron temperature and power flux at the outer target show a distinct peak of ∼5 mm half-width near the separatrix strike point. The corresponding profiles on the inner target do not show a similar feature. The height of the narrow peak increases with NB heating power and decreases with deuterium and impurity gas puffing. Ion orbit losses are suggested as a possible explanation of the observed profile shape

  4. Modelling of Power Fluxes during Thermal Quenches

    International Nuclear Information System (INIS)

    Konz, C.; Coster, D. P.; Lackner, K.; Pautasso, G.

    2005-01-01

    Plasma disruptions, i. e. the sudden loss of magnetic confinement, are unavoidable, at least occasionally, in present day and future tokamaks. The expected energy fluxes to the plasma facing components (PFCs) during disruptions in ITER lie in the range of tens of GW/m''2 for timescales of about a millisecond. Since high energy fluxes can cause severe damage to the PFCs, their design heavily depends on the spatial and temporal distribution of the energy fluxes during disruptions. We investigate the nature of power fluxes during the thermal quench phase of disruptions by means of numerical simulations with the B2 SOLPS fluid code. Based on an ASDEX Upgrade shot, steady-state pre-disruption equilibria are generated which are then subjected to a simulated thermal quench by artificially enhancing the perpendicular transport in the ion and electron channels. The enhanced transport coefficients flows the Rechester and Rosenbluth model (1978) for ergodic transport in a tokamak with destroyed flux surfaces, i. e. χ, D∼const. xT''5/2 where the constants differ by the square root of the mass ratio for ions and electrons. By varying the steady-state neutral puffing rate we can modify the divertor conditions in terms of plasma temperature and density. Our numerical findings indicate that the disruption characteristics depend on the pre disruptive divertor conditions. We study the timescales and the spatial distribution of the divertor power fluxes. The simulated disruptions show rise and decay timescales in the range observed at ASDEX Upgrade. The decay timescale for the central electron temperature of ∼800 μs is typical for non-ITB disruptions. Varying the divertor conditions we find a distinct transition from a regime with symmetric power fluxes to inboard and outboard divertors to a regime where the bulk of the power flux goes to the outboard divertor. This asymmetry in the divertor peak fluxes for the higher puffing case is accompanied by a time delay between the

  5. Critical need for MFE: the Alcator DX advanced divertor test facility

    Science.gov (United States)

    Vieira, R.; Labombard, B.; Marmar, E.; Irby, J.; Wolf, S.; Bonoli, P.; Fiore, C.; Granetz, R.; Greenwald, M.; Hutchinson, I.; Hubbard, A.; Hughes, J.; Lin, Y.; Lipschultz, B.; Parker, R.; Porkolab, M.; Reinke, M.; Rice, J.; Shiraiwa, S.; Terry, J.; Theiler, C.; Wallace, G.; White, A.; Whyte, D.; Wukitch, S.

    2013-10-01

    Three critical challenges must be met before a steady-state, power-producing fusion reactor can be realized: how to (1) safely handle extreme plasma exhaust power, (2) completely suppress material erosion at divertor targets and (3) do this while maintaining a burning plasma core. Advanced divertors such as ``Super X'' and ``X-point target'' may allow a fully detached, low temperature plasma to be produced in the divertor while maintaining a hot boundary layer around a clean plasma core - a potential game-changer for magnetic fusion. No facility currently exists to test these ideas at the required parallel heat flux densities. Alcator DX will be a national facility, employing the high magnetic field technology of Alcator combined with high-power ICRH and LHCD to test advanced divertor concepts at FNSF/DEMO power exhaust densities and plasma pressures. Its extended vacuum vessel contains divertor cassettes with poloidal field coils for conventional, snowflake, super-X and X-point target geometries. Divertor and core plasma performance will be explored in regimes inaccessible in conventional devices. Reactor relevant ICRF and LH drivers will be developed, utilizing high-field side launch platforms for low PMI. Alcator DX will inform the conceptual development and accelerate the readiness-for-deployment of next-step fusion facilities.

  6. Physics Design Requirements for the National Spherical Torus Experiment Liquid Lithium Divertor

    Energy Technology Data Exchange (ETDEWEB)

    Kugel, W.; Bell, M.; Berzak,L.; Brooks, A.; Ellis, R.; Gerhardt, S.; Harjes, H.; Kaita, R.; Kallman, J.; Maingi, R.; Majeski, R.; Mansfield, D.; Menard, J.; Nygren,R. E.; Soukhanovskii, V.; Stotler, D.; Wakeland, P.; Zakharov L. E.

    2008-09-26

    Recent NSTX high power divertor experiments have shown significant and recurring benefits of solid lithium coatings on PFC's to the performance of divertor plasmas in both L- and H- mode confinement regimes heated by high-power neutral beams. The next step in this work is installation of a liquid lithium divertor (LLD) to achieve density control for inductionless current drive capability (e.g., about a 15-25% ne decrease from present highest non-inductionless fraction discharges which often evolve toward the density limit, ne/nGW~1), to enable ne scan capability (x2) in the H-mode, to test the ability to operate at significantly lower density for future ST-CTF reactor designs (e.g., ne/nGW = 0.25), and eventually to investigate high heat-flux power handling (10 MW/m2) with longpulse discharges (>1.5s). The first step (LLD-1) physics design encompasses the desired plasma requirements, the experimental capabilities and conditions, power handling, radial location, pumping capability, operating temperature, lithium filling, MHD forces, and diagnostics for control and characterization.

  7. Physics Design Requirements for the National Spherical Torus Experiment Liquid Lithium Divertor

    International Nuclear Information System (INIS)

    Kugel, W.; Bell, M.; Berzak, L.; Brooks, A.; Ellis, R.; Gerhardt, S.; Harjes, H.; Kaita, R.; Kallman, J.; Maingi, R.; Majeski, R.; Mansfield, D.; Menard, J.; Nygren, R. E.; Soukhanovskii, V.; Stotler, D.; Wakeland, P.; Zakharov, L. E.

    2008-01-01

    Recent NSTX high power divertor experiments have shown significant and recurring benefits of solid lithium coatings on PFC's to the performance of divertor plasmas in both L- and H- mode confinement regimes heated by high-power neutral beams. The next step in this work is installation of a liquid lithium divertor (LLD) to achieve density control for inductionless current drive capability (e.g., about a 15-25% ne decrease from present highest non-inductionless fraction discharges which often evolve toward the density limit, ne/nGW∼1), to enable ne scan capability (x2) in the H-mode, to test the ability to operate at significantly lower density for future ST-CTF reactor designs (e.g., ne/nGW = 0.25), and eventually to investigate high heat-flux power handling (10 MW/m2) with long pulse discharges (>1.5s). The first step (LLD-1) physics design encompasses the desired plasma requirements, the experimental capabilities and conditions, power handling, radial location, pumping capability, operating temperature, lithium filling, MHD forces, and diagnostics for control and characterization

  8. Design improvement of the target elements of Wendelstein 7-X divertor

    International Nuclear Information System (INIS)

    Boscary, J.; Peacock, A.; Friedrich, T.; Greuner, H.; Böswirth, B.; Tittes, H.; Schulmeyer, W.; Hurd, F.

    2012-01-01

    Highlights: ► Improvement of the cooling structure design. ► Improvement of the CFC tile arrangement at the element end. ► Design and fabrication validated with high heat flux testing. ► Selected solution removes stationary heat load of 5 MW/m 2 and 2 MW/m 2 on the top and on the side facing the pumping gap of the element, respectively. - Abstract: The actively cooled high-heat flux divertor of the Wendelstein 7-X stellarator consists of individual target elements made of a water-cooled CuCrZr copper alloy heat sink armored with CFC tiles. The so-called “bi-layer” technology developed in collaboration with the company Plansee for the bonding of the tiles onto the heat sink has reliably demonstrated the removal of the specified heat load of 10 MW/m 2 in the central area of the divertor. However, due to geometrical constraints, the loading performance at the ends of the elements is reduced compared to the central part. Design modifications compatible with industrial processes have been made to improve the cooling capabilities at this location. These changes have been validated during test campaigns of full-scale prototypes carried out in the neutral beam test facility GLADIS. The tested solution can remove reliably the stationary heat load of 5 MW/m 2 and 2 MW/m 2 on the top and on the side of the element, respectively. The results of the testing allowed the release of the design and fabrication processes for the next manufacturing phase of the target elements.

  9. Plasma-Materials Interactions (PMI) and High-Heat-Flux (HHF) component research and development in the US Fusion Program

    International Nuclear Information System (INIS)

    Conn, R.W.

    1986-10-01

    Plasma particle and high heat fluxes to in-vessel components such as divertors, limiters, RF launchers, halo plasma scrapers, direct converters, and wall armor, and to the vacuum chamber itself, represent central technical issues for fusion experiments and reactors. This is well recognized and accepted. It is also well recognized that the conditions at the plasma boundary can directly influence core plasma confinement. This has been seen most dramatically, on the positive side, in the discovery of the H-mode using divertors in tokamaks. It is also reflected in the attention devoted worldwide to the problems of impurity control. Nowadays, impurities are controlled by wall conditioning, special discharge cleaning techniques, special coatings such as carbonization, the use of low-Z materials for limiters and armor, a careful tailoring of heat loads, and in some machines, through the use of divertors. All programs, all experiments, and all designers are now keenly aware that PMI and HHF issues are key to the successful performance of their machines. In this brief report we present general issues in Section 2, critical issues in Section 3, existing US PMI/HHF experiments and facilities in Section 4, US International Cooperative PMI/HHF activities in Section 5, and conclude with a discussion on major tasks in PMI/HHF in Section 6

  10. Mechanical Design of the NSTX Liquid Lithium Divertor

    Energy Technology Data Exchange (ETDEWEB)

    R. Ellis, R. Kaita, H. Kugel, G. Paluzzi, M. Viola and R. Nygren

    2009-02-19

    The Liquid Lithium Divertor (LLD) on NSTX will be the first test of a fully-toroidal liquid lithium divertor in a high-power magnetic confinement device. It will replace part of the lower outboard divertor between a specified inside and outside radius, and ultimately provide a lithium surface exposed to the plasma with enough depth to absorb a significant particle flux. There are numerous technical challenges involved in the design. The lithium layer must be as thin as possible, and maintained at a temperature between 200 and 400 degrees Celsius to minimize lithium evaporation. This requirement leads to the use of a thick copper substrate, with a thin stainless steel layer bonded to the plasma-facing surface. A porous molybdenum layer is then plasma-sprayed onto the stainless steel, to provide a coating that facilitates full wetting of the surface by the liquid lithium. Other challenges include the design of a robust, vacuumcompatible heating and cooling system for the LLD. Replacement graphite tiles that provided the proper interface between the existing outer divertor and the LLD also had to be designed, as well as accommodation for special LLD diagnostics. This paper describes the mechanical design of the LLD, and presents analyses showing the performance limits of the LLD.

  11. Mechanical Design of the NSTX Liquid Lithium Divertor

    International Nuclear Information System (INIS)

    Ellis, R.; Kaita, R.; Kugel, H.; Paluzzi, G.; Viola, M.; Nygren, R.

    2009-01-01

    The Liquid Lithium Divertor (LLD) on NSTX will be the first test of a fully-toroidal liquid lithium divertor in a high-power magnetic confinement device. It will replace part of the lower outboard divertor between a specified inside and outside radius, and ultimately provide a lithium surface exposed to the plasma with enough depth to absorb a significant particle flux. There are numerous technical challenges involved in the design. The lithium layer must be as thin as possible, and maintained at a temperature between 200 and 400 degrees Celsius to minimize lithium evaporation. This requirement leads to the use of a thick copper substrate, with a thin stainless steel layer bonded to the plasma-facing surface. A porous molybdenum layer is then plasma-sprayed onto the stainless steel, to provide a coating that facilitates full wetting of the surface by the liquid lithium. Other challenges include the design of a robust, vacuum compatible heating and cooling system for the LLD. Replacement graphite tiles that provided the proper interface between the existing outer divertor and the LLD also had to be designed, as well as accommodation for special LLD diagnostics. This paper describes the mechanical design of the LLD, and presents analyses showing the performance limits of the LLD.

  12. Conceptual design of a He-cooled divertor with integrated flow and heat transfer promoters (PPCS subtask TW3-TRP-001-D2). Pt. 1. Summary

    International Nuclear Information System (INIS)

    Norajitra, P.; Kruessmann, R.

    2004-04-01

    Within the framework of the EU power plant conceptual study (PPCS), helium-cooled modular divertor concepts with a flow promoter (HEMP as a pin array and HEMS as slot array version) have been investigated at the Forschungszentrum Karlsruhe since 2002. The design goal is to achieve a high heat flux performance of 15 MW/m 2 . In this summary of the detailed report, research areas related to the development of a helium-cooled divertor shall be addressed. Latest changes in thermohydraulic layout as well as current results of simulation calculations shall be presented exemplarily for the slot concept HEMS which has the crucial advantage of being easier to manufacture. The divertor construction resulting from the requirements as well as the design-related issues shall be discussed. Possible manufacturing processes for divertor components of tungsten are assessed. Chapters 7 and 8 have been completely revised comprising the latest results of the thermohydraulic layout and thermomechanical analyses. Calculation results have to be verified by experiments. For this purpose, a helium loop will be built at the Efremov Institute, St. Petersburg, Russia, in 2004. An outlook on an alternative multi-jet design (HEMJ) will be given at the end of this report. (orig.)

  13. Development of residual thermal stress-relieving structure of CFC monoblock target for JT-60SA divertor

    Energy Technology Data Exchange (ETDEWEB)

    Tsuru, Daigo, E-mail: tsuru.daigo@jaea.go.jp; Sakurai, Shinji; Nakamura, Shigetoshi; Ozaki, Hidetsugu; Seki, Yohji; Yokoyama, Kenji; Suzuki, Satoshi

    2015-10-15

    Highlights: • We carried out numerical simulations on residual thermal stress of targets for the JT-60SA divertor. • We developed three measures to reduce residual thermal stress. • We proposed two structures of CFC monoblock target for the JT-60SA divertor. • We confirmed the effectiveness of the structure by infrared thermography inspection and high heat flux test. - Abstract: Carbon fibre-reinforced carbon composite (CFC) monoblock target for JT-60SA divertor is under development towards the mass-production. CFC monoblocks, WCu interlayers and a CuCrZr cooling tube at the centre of the monoblocks were bonded by vacuum brazing in a high temperature, to a target. If residual thermal stress due to difference of thermal expansions between CFC and CuCrZr exceeds the maximum allowable stress of the CFC after the bonding, cracks are generated in the CFC monoblock and heat removal capacity of the target degrades. In this paper, new structures of the targets were proposed, to reduce residual thermal stress and to mitigate the degradation of heat removal capacity of the targets. Some measures, including slitting of the CFC monoblock aside of the cooling tube, replacement of the interlayer material and shifting the position of the cooling tube, were implemented. The effectiveness of the measures was evaluated by numerical simulations. Target mock-ups with the proposed structures were manufactured. Infrared thermography inspection and high heat flux test were carried out on the mock-ups in order to evaluate the heat removal capacity.

  14. Heat flux microsensor measurements

    Science.gov (United States)

    Terrell, J. P.; Hager, J. M.; Onishi, S.; Diller, T. E.

    1992-01-01

    A thin-film heat flux sensor has been fabricated on a stainless steel substrate. The thermocouple elements of the heat flux sensor were nickel and nichrome, and the temperature resistance sensor was platinum. The completed heat flux microsensor was calibrated at the AEDC radiation facility. The gage output was linear with heat flux with no apparent temperature effect on sensitivity. The gage was used for heat flux measurements at the NASA Langley Vitiated Air Test Facility. Vitiated air was expanded to Mach 3.0 and hydrogen fuel was injected. Measurements were made on the wall of a diverging duct downstream of the injector during all stages of the hydrogen combustion tests. Because the wall and the gage were not actively cooled, the wall temperature reached over 1000 C (1900 F) during the most severe test.

  15. Thermographic observation of the divertor target plates in the stellarators W7-AS and W7-X

    International Nuclear Information System (INIS)

    Hildebrandt, D.; Gadelmeier, F.; Grigull, P.; McCormick, K.; Naujoks, D.; Suender, D.

    2003-01-01

    Thermography is applied on the stellarator W7-AS to monitor the thermal load of the recently installed divertor targets. A three dimensional numerical code was developed to evaluate power fluxes arriving at the targets from the measured temporal evolution of the surface temperature distribution. Values of the thermal conductivity of the used CFC-target material for all three directions are required for this evaluation and determined by observing the propagation of controlled heat pulses applied by an infrared laser. The evaluation of the thermographic measurements during plasma operation shows characteristic spatial and temporal features of the arrived heat fluxes. Significant features in high density regimes like plasma detachment from the divertor target plates or strongly enhanced localised plasma radiation (MARFE) has been observed by the installed infrared cameras. The implications of these observations for the thermographic system for W7-X are shortly addressed

  16. SOLPS simulations of X-divertor in NSTX-U

    Science.gov (United States)

    Chen, Zhongping; Kotschenreuther, Mike; Mahajan, Swadesh

    2017-10-01

    The X-divertor (XD) geometry in NSTX-U has demonstrated, in SOLPS simulations, a better performance than the standard divertor (SD) regarding detachment: achieving detachment with a lower upstream density and stabilizing the detachment front near the target. The benefits of such a localized front is that the power exhaust requirement can be satisfied without the radiation front encroaching on the core plasma. It is also found by our simulations that at similar states of detachment the XD outperforms the SD by reducing the heat fluxes to the target and maintaining higher upstream temperatures. These advantages are attributed to the unique geometric characteristics of XD - poloidal flaring near the target. The detailed physical mechanisms behind the better XD performance that is found in the simulations will be examined. Work supported by US DOE under DE-FG02-04ER54742 and SC 0012956.

  17. European DEMO divertor target: Operational requirements and material-design interface

    Directory of Open Access Journals (Sweden)

    J.H. You

    2016-12-01

    Full Text Available Recently, an integrated program of conceptual design activities for the European DEMO reactor was launched in the framework of the EUROfusion Consortium, where reliable power handling capability was identified as one of the most critical scientific as well as technological challenges for a DEMO reactor. The divertor is the key in-vessel plasma-facing component being in charge of power exhaust and removal of impurity particles. The DEMO divertor target will have to withstand extreme thermal loads where the local peak heat flux is expected to reach up to 20 MW/m2 during slow transient events in DEMO. To assure sufficient heat removal capability of the divertor target against normal and transient operational scenarios under expected cumulative neutron dose of up to 13 dpa is one of the fundamental engineering challenges imposed on target design. To develop the design of the DEMO divertor and related technologies, an R&D work package ‘Divertor’ has been set up in this consortium. The subproject ‘Target Development’ is devoted to the development of the conceptual design and the core technologies of the plasma-facing target. Devising and implementing novel structural heat sink materials (e.g. W/Cu composites to advanced target design concepts is one of the major objectives of this subproject. In this paper, the underlying design requirements imposed by the envisaged power exhaust goal and the prominent material-design interface issues are discussed. In addition, the candidate design concepts being currently considered are presented together with the related material issues. Finally, the first results achieved so far are presented.

  18. Technologies for ITER divertor vertical target plasma facing components

    International Nuclear Information System (INIS)

    Schlosser, J.; Escourbiac, F.; Merola, M.; Fouquet, S.; Bayetti, P.; Cordier, J.J.; Grosman, A.; Missirlian, M.; Tivey, R.; Roedig, M.

    2005-01-01

    The ITER divertor vertical target has to sustain heat fluxes up to 20 MW m -2 . The concept developed for this plasma facing component working at steady state is based on carbon fibre composite armour for the lower straight part and tungsten for the curved upper part. The main challenges involved in the use of such components include the removal of the high heat fluxes deposited and mechanically and thermally joining the armour to the metallic heat sink, despite the mismatch in the thermal expansions. Two solutions based on the use of a CuCrZr hardened copper alloy and an active metal casting (AMC (registered) ) process were investigated during the ITER EDA phase: the first one called 'flat tile geometry' was mainly developed for the Tore Supra pumped limiter, the second one called 'monoblock geometry' was developed by the EU Participating Team for the ITER project. This paper presents a review of these two solutions and analyses their assets and drawbacks: pressure drop, critical heat flux, surface temperature and expected behaviour during operation, risks during the manufacture, control of the armour defects during the manufacture and at the reception, and the possibility of repairing defective tiles

  19. Self-castellation of tungsten monoblock under high heat flux loading and impact of material properties

    Directory of Open Access Journals (Sweden)

    S. Panayotis

    2017-08-01

    Full Text Available In the full-tungsten divertor qualification program at ITER Organization, macro-cracks, so called self-castellation were found in a fraction of tungsten monoblocks during cyclic high heat flux loading at 20MW/m2. The number of monoblocks with macro-cracks varied with the tungsten products used as armour material. In order to understand correlation between the macro-crack appearance and W properties, an activity to characterize W monoblock materials was launched at the IO. The outcome highlighted that the higher the recrystallization resistance, the lower the number of cracks detected during high heat flux tests. Thermo-mechanical finite element modelling demonstrated that the maximum surface temperature ranges from 1800 °C to 2200 °C and in this range recrystallization of tungsten occurred. Furthermore, it indicated that loss of strength due to recrystallization is responsible for the development of macro-cracks in the tungsten monoblock.

  20. Driving mechanism of SOL plasma flow and effects on the divertor performance in JT-60U

    International Nuclear Information System (INIS)

    Asakura, N.

    2002-01-01

    SOL plasma flow plays an important role in the plasma transport along the field lines, and influences control of the divertor plasma and impurity ions. Recently, mechanisms producing the SOL flow such as drifts produced by electric field and pressure gradient are pointed out. In JT-60U, three reciprocating Mach probes were installed at the high-field-side (HFS) baffle, low-field-side (LFS) midplane and just below the X-point. The measurements of the SOL flow and plasma profiles both at the HFS and LFS, for the first time, found out the SOL flow pattern and its driving mechanism. 'Flow reversal' was found near the separatrix of the HFS and LFS. Radial profiles of the SOL flow were similar to those calculated numerically using the UEDGE code with the plasma drifts included. SOL particle fluxes towards the HFS and LFS divertors were, for the first time, evaluated. Important physics issues for the divertor design and operation, such as in-out asymmetries of the heat and particle fluxes, and control of impurity ions with intense gas puff and divertor pump (puff and pump), were investigated. (author)

  1. Possible divertor solutions for a fusion reactor. Pt. I. Physical aspects based on present day divertor operation

    International Nuclear Information System (INIS)

    Kallenbach, A.; Bosch, H.-S.; De Pena Hempel, S.; Dux, R.; Kaufmann, M.; Mertens, V.; Neuhauser, J.; Suttrop, W.; Zohm, H.

    1997-01-01

    For pt.II see ibid., p.109-117 (1997). With an anticipated power flux across the separatrix of up to 300 MW of an ITER-like fusion reactor, conventional measures of power spread lead to a peak power load at the target plates in the order of 30 MW m -2 , far beyond the technically feasible limit for stationary operation. Radiative cooling by seed impurities appears to be the most promising plasma-physical option to reduce the target power load, but extrapolations of present experiments predict an only marginally tolerable increase of the plasma effective charge Z eff . Key points will be the achievement of very high electron densities, leading to more effective radiative cooling by δP rad /δZ eff ∝n e 2 while keeping the edge temperature within its optimum range. This range is bounded from below by the H→L mode temperature threshold due to confinement requirements, whereas the upper boundary is given by the ideal ballooning stability limit which is connected to type-I ELM activity which may cause non-tolerable divertor heat loads. The completely detached H-mode (CDH) in ASDEX Upgrade demonstrates radiative H-mode operation within this operational range exhibiting high-frequent type-III ELMs and target power load in the order of 10% of the heating power. At present, open questions on high density reactor operation are related to radiative instabilities as well as edge transport enhancement and H-mode impairment observed in several tokamaks under high density conditions. Measures to overcome these detrimental effects will be investigated with improved divertor concepts in the near future. The possible problems connected to high density reactor operation can be relaxed, if the design of plasma facing components with higher heat flux endurance is successful. (orig.)

  2. Thermal-hydraulic tests on net divertor targets using swirl tubes

    International Nuclear Information System (INIS)

    Schlosser, J.; Chappuis, P.; Deschamps, P.; Massmann, P.; Falter, H.D.; Deschamps, G.H.

    1991-01-01

    Thermal-hydraulic tests have been carried out in collaboration between NET, CEA Cadarache and JET in order to find a cooling method capable of removing the high heat fluxes expected for the NET/ITER divertor. The goal was to evaluate by experiments the critical heat flux (CHF) and heat transfer in the subcooled boiling regime using twisted tapes as turbulence promoters and testing them under relevant thermal-hydraulic conditions. The CEA 200 kW Electron Beam (EB) facility and the 10 MW JET Neutral Beam (NB) test bed have been used to heat up the NET relevant test sections (TS) consisting of rectangular copper elements with circular internal channels. The TS have been exposed to the electron or ion beams under normal incidence. This paper reports the results of the experiments and of thermal analyses performed in support of the tests. The experimental CHF values have been benchmarked with the Tong-75 correlation

  3. The ITER divertor concept

    International Nuclear Information System (INIS)

    Janeschitz, G.; Borrass, K.; Federici, G.; Igitkhanov, Y.; Kukushkin, A.; Pacher, H.D.; Pacher, G.W.; Sugihara, M.

    1995-01-01

    The ITER divertor must exhaust most of the alpha particle power and the He ash at acceptable erosion rates. The high recycling regime of the ITER-CDA for present parameters would yield high power loads and erosion rates on conventional targets. Improvement by radiation in the SOL at constant pressure is limited in principle. To permit a higher radiation fraction, the plasma pressure along the field must be reduced by more than a factor 10, reducing also the target ion flux. This pressure reduction can be obtained by strong plasma-neutral interaction below the X-point. Under these conditions T e in the divertor can be reduced to <5 eV along a flame like ionisation front by impurity radiation and CX losses. Downstream of the front, neutrals undergo more CX or i-n collisions than ionisation events, resulting in significant momentum loss via neutrals to the divertor chamber wall. The pressure reduction by this mechanism depends on the along-field length for neutral-plasma interaction, the parallel power flux, the neutral density, the ratio of neutral-neutral collision length to the plasma-wall distance and on the Mach number of ions and neutrals. A supersonic transition in the main plasma-neutral interaction region, expected to occur near the ionisation front, would be beneficial for momentum removal. The momentum transfer fraction to the side walls is calculated: low Knudsen number is beneficial. The impact of the different physics effects on the chosen geometry and on the ITER divertor design and the lifetime of the various divertor components are discussed. ((orig.))

  4. The contribution of radio-frequency rectification to field-aligned losses of high-harmonic fast wave power to the divertor in the National Spherical Torus eXperiment

    Energy Technology Data Exchange (ETDEWEB)

    Perkins, R. J., E-mail: rperkins@pppl.gov; Hosea, J. C.; Jaworski, M. A.; Diallo, A.; Bell, R. E.; Bertelli, N.; Gerhardt, S.; Kramer, G. J.; LeBlanc, B. P.; Phillips, C. K.; Podestà, M.; Roquemore, L.; Taylor, G.; Wilson, J. R. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Ahn, J.-W.; Gray, T. K. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); McLean, A. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Sabbagh, S. [Department of Applied Physics and Applied Mathematics, Columbia University, New York, New York 10027 (United States)

    2015-04-15

    The National Spherical Torus eXperiment (NSTX) can exhibit a major loss of high-harmonic fast wave (HHFW) power along scrape-off layer (SOL) field lines passing in front of the antenna, resulting in bright and hot spirals on both the upper and lower divertor regions. One possible mechanism for this loss is RF sheaths forming at the divertors. Here, we demonstrate that swept-voltage Langmuir probe characteristics for probes under the spiral are shifted relative to those not under the spiral in a manner consistent with RF rectification. We estimate both the magnitude of the RF voltage across the sheath and the sheath heat flux transmission coefficient in the presence of the RF field. Although precise comparison between the computed heat flux and infrared (IR) thermography cannot yet be made, the computed heat deposition compares favorably with the projections from IR camera measurements. The RF sheath losses are significant and contribute substantially to the total SOL losses of HHFW power to the divertor for the cases studied. This work will guide future experimentation on NSTX-U, where a wide-angle IR camera and a dedicated set of coaxial Langmuir probes for measuring the RF sheath voltage directly will quantify the contribution of RF sheath rectification to the heat deposition from the SOL to the divertor.

  5. Thick boron carbide coatings for protection of tokamak first wall and divertor

    International Nuclear Information System (INIS)

    Buzhinskij, O.I.; Semenets, Yu.M.

    1999-01-01

    A review of characteristics of various types of boron carbide coatings considered as candidate materials for protection of tokamak inner surfaces against high energy heat fluxes is presented. Such coatings are produced by various methods: chemical vapor deposition by means of chloride and fluoride techniques, gas conversion, plasma spray and reaction-sintering. Contrary to pure carbon materials, B 4 C has much lower chemical and high-temperature sputtering, is capable to oxygen gettering and lower hydrogen recycling. In contrast to thin boronization films, the thick coatings can resist high heat fluxes such as in tokamak divertors. Comparative analysis shows that coatings produced by the diffusion methods, such as fluoride CVD and gas conversion, are more resistent to heat loads, and one of the most promising candidates are the fluoride CVD coatings. (orig.)

  6. Physics design requirements for the National Spherical Torus Experiment liquid lithium divertor

    International Nuclear Information System (INIS)

    Kugel, H.; Bell, M.; Berzak, L.; Brooks, A.; Ellis, R.; Gerhardt, S.P.; Kaita, R.; Kallman, J.; Majeski, R.; Mansfield, D.K.; Menard, J.; Stotler, D.; Zakharov, L.E.; Maingi, Rajesh; Nygren, R.E.; Soukhanovskii, V.; Wakeland, P.

    2009-01-01

    Recent National Spherical Tokamak Experiment (NSTX) high-power divertor experiments have shown significant and recurring benefits of solid lithium coatings on plasma facing components (PFCs) to the performance of divertor plasmas in both L- and H-mode confinement regimes heated by high-power neutral beams. The next step in this work is installation of a liquid lithium divertor (LLD) to achieve density control for inductionless current drive capability (e.g., about a 15 25% ne decrease from present highest non-inductionless fraction discharges which often evolve toward the density limit, ne/nGW 1), to enable ne scan capability (2) in the H-mode, to test the ability to operate at significantly lower density (e.g., ne/nGW = 0.25), for future reactor designs based on the Spherical Tokamak, and eventually to investigate high heat-flux power handling (10 MW/m2) with long pulse discharges (>1.5 s). The first step (LLD-1) physics design encompasses the desired plasma requirements, the experimental capabilities and conditions, power handling, radial location, pumping capability, operating temperature, lithium filling, MHD forces, and diagnostics for control and characterization.

  7. NSTX Tangential Divertor Camera

    International Nuclear Information System (INIS)

    Roquemore, A.L.; Ted Biewer; Johnson, D.; Zweben, S.J.; Nobuhiro Nishino; Soukhanovskii, V.A.

    2004-01-01

    Strong magnetic field shear around the divertor x-point is numerically predicted to lead to strong spatial asymmetries in turbulence driven particle fluxes. To visualize the turbulence and associated impurity line emission near the lower x-point region, a new tangential observation port has been recently installed on NSTX. A reentrant sapphire window with a moveable in-vessel mirror images the divertor region from the center stack out to R 80 cm and views the x-point for most plasma configurations. A coherent fiber optic bundle transmits the image through a remotely selected filter to a fast camera, for example a 40500 frames/sec Photron CCD camera. A gas puffer located in the lower inboard divertor will localize the turbulence in the region near the x-point. Edge fluid and turbulent codes UEDGE and BOUT will be used to interpret impurity and deuterium emission fluctuation measurements in the divertor

  8. Module of lithium divertor for KTM tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Lyublinski, I., E-mail: yublinski@yandex.ru [FSUE ' Red Star' , Moscow (Russian Federation); Vertkov, A.; Evtikhin, V.; Balakirev, V.; Ionov, D.; Zharkov, M. [FSUE ' Red Star' , Moscow (Russian Federation); Tazhibayeva, I. [IAE NNC RK, Kurchatov (Kazakhstan); Mirnov, S. [TRINITI, Troitsk, Moscow Region (Russian Federation); Khomiakov, S.; Mitin, D. [OJSC Dollezhal Institute, Moscow (Russian Federation); Mazzitelli, G. [ENEA RC Frascati (Italy); Agostini, P. [ENEA RC Brasimone (Italy)

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer Problems of PFE degradation, tritium accumulation and plasma pollution can be overcome by the use of liquid lithium-metal with low Z. Black-Right-Pointing-Pointer Capillary-porous system (CPS) - new material in which liquid lithium fill a solid matrix from porous material. Black-Right-Pointing-Pointer Lithium divertor module for KTM tokamak is under development. Black-Right-Pointing-Pointer Lithium filled tungsten felt is offered as the base plasma facing material of divertor. Black-Right-Pointing-Pointer Results of this project addresses to the progress in the field of fusion neutrons source and fusion energy source creation. - Abstract: Activity on projects of ITER and DEMO reactors has shown that solution of problems of divertor target plates and other plasma facing elements (PFEs) based on the solid plasma facing materials cause serious difficulties. Problems of PFE degradation, tritium accumulation and plasma pollution can be overcome by the use of liquid lithium-metal with low Z. Application of lithium will allow to create a self-renewal and MHD stable liquid metal surface of the in-vessel devices possessing practically unlimited service life; to reduce power flux due to intensive re-irradiation on lithium atoms in plasma periphery that will essentially facilitate a problem of heat removal from PFE; to reduce Z{sub eff} of plasma to minimally possible level close to 1; to exclude tritium accumulation, that is provided with absence of dust products and an opportunity of the active control of the tritium contents in liquid lithium. Realization of these advantages is based on use of so-called lithium capillary-porous system (CPS) - new material in which liquid lithium fill a solid matrix from porous material. The progress in development of lithium technology and also activity in lithium experiments in the tokamaks TFTR, T-11M, T-10, FTU, NSTX, HT-7 and stellarator TJ II permits of solving the problems in development of

  9. The effect of density on divertor conditions in ASDEX-Upgrade

    International Nuclear Information System (INIS)

    Pitcher, C.S.; Bosch, H.-S.; Buechl, K.; Field, A.; Fuchs, C.; Haas, G.; Junker, W.; Neu, R.; Neuhauser, J.; Wenzel, U.

    1995-01-01

    Detailed experimental divertor data are presented on the profiles of density and temperature in the inner and outer divertor fans, the radiated power distribution, the gas pressure and the spectroscopically derived particle fluxes, all as a function of the discharge density. At low and medium density, the inner divertor is cold and dense compared to the outer divertor. At high density, strong X-point MARFE and separatrix radiation partially detaches the inner divertor. Probe measurements which penetrate into the X-point MARFE at the outer divertor are presented. ((orig.))

  10. Theory of Advanced Magnetic Divertors

    Science.gov (United States)

    Kotschenreuther, Michael; Valanju, Prashant; Mahajan, Swadesh; Covele, Brent

    2013-10-01

    The magnetic field structure in the SOL is the most important determinant of divertor physics. A comprehensive analytical and numerical methodology is developed to investigate SOL magnetic fields in the backdrop of two advanced divertor geometries- the X-divertor (XD) proposed and discussed in 2004, and the snowflake divertor (SFD) of 2007-2010. The analysis shows that XD and SFD represent very distinct and readily distinguishable magnetic geometries, epitomized through a differentiating metric, the Divertor Index (DI). In terms of this simple metric, the XD (DI > 1) and the SFD (DI XD flux surfaces are less convergent, in fact, divergent (flaring). These different SOL magnetics imply different physics, particularly with respect to detachment dynamics. It is also shown that some experiments on NSTX and DIII-D match both the prescription and the predictions of the 2004 XD paper. Work supported under US-DOE projects DE-FG02-04ER54742 and DE-FG02-04ER54754.

  11. Effect of separatrix magnetic geometry on divertor behavior in DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Petrie, T.W., E-mail: petrie@fusion.gat.com [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Canik, J.M. [Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831 (United States); Lasnier, C.J. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Leonard, A.W.; Mahdavi, M.A. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Watkins, J.G. [Sandia National Laboratories, P.O. Box 5800, Albuquerque, NM 87185 (United States); Fenstermacher, M.E. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Ferron, J.R.; Groebner, R.J. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Hill, D.N. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Hyatt, A.W. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Holcomb, C.T. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Luce, T.C. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Moyer, R.A. [University of California–San Diego, La Jolla, CA 92093-0417 (United States); Stangeby, P.C. [University of Toronto Institute of Aerospace Studies, Toronto (Canada)

    2013-07-15

    We report on recent experiments on DIII-D that examined the effects that variations in the parallel connection length in the scrape-off layer (SOL), L{sub ||}, and the radial location of the outer divertor target, R{sub TAR}, have on divertor plasma properties. Two-point modeling of the SOL plasma predicts that larger values of L{sub ||} and R{sub TAR} should lower temperature and raise density at the outer divertor target for fixed upstream separatrix density and temperature, i.e., n{sub TAR} ∝ [R{sub TAR}]{sup 2}[L{sub ||}]{sup 6/7} and T{sub TAR} ∝ [R{sub TAR}]{sup −2}[L{sub ||}]{sup −4/7}. The dependence of n{sub TAR} and T{sub TAR} on L{sub ||} was consistent with our data, but the dependence of n{sub TAR} and T{sub TAR} on R{sub TAR} was not. The surprising result that the divertor plasma parameters did not depend on R{sub TAR} in the predicted way may be due to convected heat flux, driven by escaping neutrals, in the more open configuration of the larger R{sub TAR} cases. Modeling results using the SOLPS code support this postulate.

  12. Heat transfer and critical heat flux in a asymmetrically heated tube helicoidal flow

    International Nuclear Information System (INIS)

    Boscary, J.

    1995-10-01

    The design of plasma facing components is crucial for plasma performance in next fusion reactors. These elements will be submitted to very high heat flux. They will be actively water-cooled by swirl tubes in the subcooled boiling regime. High heat flux experiments were conducted in order to analyse the heat transfer and to evaluate the critical heat flux. Water-cooled mock-ups were one-side heated by an electron beam gun for different thermal-hydraulic conditions. The critical heat flux was detected by an original method based on the isotherm modification on the heated surface. The wall heat transfer law including forced convection and subcooled boiling regimes was established. Numerical calculations of the material heat transfer conduction allowed the non-homogeneous distribution of the wall temperature and of the wall heat flux to be evaluated. The critical heat flux value was defined as the wall maximum heat flux. A critical heat flux model based on the liquid sublayer dryout under a vapor blanket was established. A good agreement with test results was found. (author). 198 refs., 126 figs., 21 tabs

  13. Application of tungsten-fibre-reinforced copper matrix composites to a high-heat-flux component: A design study by dual scale finite element analysis

    International Nuclear Information System (INIS)

    Jeong-Ha You

    2006-01-01

    According to the European Power Plant Conceptual Study, actively cooled tungsten mono-block is one of the divertor design options for fusion reactors. In this study the coolant tube acts as a heat sink and the tungsten block as plasma-facing armour. A key material issue here is how to achieve high temperature strength and high heat conductivity of the heat sink tube simultaneously. Copper matrix composite reinforced with continuous strong fibres has been considered as a candidate material for heat sink of high-heat-flux components. Refractory tungsten wire is a promising reinforcement material due to its high strength, winding flexibility and good interfacial wetting with copper. We studied the applicability of tungsten-fibre-reinforced copper matrix composite heat sink tubes for the tungsten mono-block divertor by means of dual-scale finite element analysis. Thermo-elasto-plastic micro-mechanics homogenisation technique was applied. A heat flux of 15 MW/m 2 with cooling water temperature of 320 o C was considered. Effective stress-free temperature was assumed to be 500 o C. Between the tungsten block and the composite heat sink tube interlayer (1 mm thick) of soft Cu was inserted. The finite element analysis yields the following results: The predicted maximum temperature at steady state is 1223 o C at the surface and 562 o C at the interface between tube and copper layer. On the macroscopic scale, residual stress is generated during fabrication due to differences in thermal expansion coefficients of the materials. Strong compressive stress occurs in the tungsten block around the tube while weak tensile stress is present in the interlayer. The local and global probability of brittle failure of the tungsten block was also estimated using the probabilistic failure theories. The thermal stresses are significantly decreased upon subsequent heat flux loading. Resolving the composite stress on microscopic scale yields a maximum fibre axial stress of 3000 MPa after

  14. Modeling of thermal effects on TIBER II [Tokamak Ignition/Burn Experimental Reactor] divertor during plasma disruption

    International Nuclear Information System (INIS)

    Bruhn, M.L.; Perkins, L.J.

    1987-01-01

    Mapping the disruption power flow from the mid-plane of the TIBER Engineering Test Reactor to its divertor and calculating the resulting thermal effects are accomplished through the modification and coupling of three presently existing computer codes. The resulting computer code TADDPAK (Thermal Analysis Divertor during Disruption PAcKage) provides three-dimensional graphic presentations of time and positional dependent thermal effects on a poloidal cross section of the double-null-divertor configured reactor. These thermal effects include incident heat flux, surface temperature, vaporization rate, total vaporization, and melting depth. The dependence of these thermal effects on material choice, disruption pulse shape, and the characteristic thickness of the plasma scrape-off layer is determined through parametric analysis with TADDPAK. This computer code is designed to be a convenient, rapid, and user-friendly modeling tool which can be easily adapted to most tokamak double-null-divertor reactor designs. 14 refs

  15. Fabrication of divertor cassette for ITER

    International Nuclear Information System (INIS)

    Sanguinetti, G.P.

    2008-01-01

    The Divertor is the component located on the bottom of the ITER vacuum vessel, whose main function is to adsorb the high thermal flux generated by the plasma whilst keeping the plasma impurity at a reasonable low level. The divertor consist of 54 units, each comprising outer components, facing the plasma and a component supporting the plasma facing components (PFC) and providing coolant distribution to them (divertor cassette). The divertor cassette is a box structure, butt welded and machined, made from plates and forgins of austenitic stainless steels. The cassette fabrication, which is in detail described, includes manufacturing of the attachments of the PFC to the cassette, the coolant distribution channels, and the cassette to vacuum vessel locking system. The divertor cassette is a pressure component (the cooling water runs at 40 bar) and therefore divertor cassette design, fabrication and service shall comply with the European PED and the applicable French law for the ITER. (orig.)

  16. High heat flux components with Be armour before and after neutron irradiation

    International Nuclear Information System (INIS)

    Lodato, A.; Derz, H.; Duwe, R.; Linke, J.; Roedig, M.

    2000-01-01

    Beryllium/copper mock-ups produced by different joining techniques have been tested in the electron beam facility JUDITH (Juelich Divertor Test Facility in Hot Cells) at Forschungszentrum Juelich. The experiments described in this paper represent the conclusive part of a test program started in 1994. The properties of non-irradiated Be/Cu joints have been characterised in a previous test campaign. Post-irradiation tests are now being carried out to investigate the neutron damage on the joints. The neutron irradiation on selected mock-ups has been carried out in the High Flux Reactor (HFR) at Petten (The Netherlands). Parametric finite element thermal analyses have been carried out to establish the allowable heat flux value to be applied during the tests. Screening tests up to power densities of ∼7 MW/m 2 and thermal fatigue tests up to 1000 cycles have been performed. None of these mock-ups showed any indication of failure. Post-mortem analyses (metallography, SEM) have also been conducted

  17. Type I ELM filament heat fluxes on the KSTAR main chamber wall

    Directory of Open Access Journals (Sweden)

    M.-K. Bae

    2017-08-01

    Full Text Available Heat loads deposited on the first wall by mitigated Type I ELMs are expected to be the dominant contributor to the total thermal plasma wall load of the International Thermonuclear Experimental Reactor (ITER, particularly in the upper main chamber regions during the baseline H-mode magnetic equilibrium, due to the fast radial convective heat propagation of ELM filaments before complete loss to the divertor. Specific Type I ELMing H-mode discharges have been performed with a lower single null magnetic geometry, where the outboard separatrix position is slowly (∼7s scanned over a radial distance of 7cm, reducing the wall probe–separatrix distance to a minimum of ∼9cm, and allowing the ELM filament heat loss to the wall to be analyzed as a function of radial propagation distance. A fast reciprocating probe (FRP head is separately held at fixed position toroidally close and 4.7cm radially in front of the wall probe. This FRP monitors the ELM ion fluxes, allowing an average filament radial propagation speed, found to be independent of ELM energy, of 80–100ms−1 to be extracted. Radial dependence of the peak filament wall parallel heat flux is observed to be exponential, with the decay length of λq, ELM ∼25 ± 4mm and with the heat flux of q∥, ELM= 0.05MWm−2 at the wall, corresponding to q∥ ∼ 7.5MWm−2 at the second separatrix. Along with the measured radial propagation speed and the calculated radial profile of the magnetic connection lengths across the SOL, these data could be utilized to analyze filament energy loss model for the future machines.

  18. Attainment of high confinement in neutral beam heated divertor discharges in the PDX tokamak

    International Nuclear Information System (INIS)

    Kaye, S.M.; Bell, M.; Bol, K.

    1983-11-01

    The PDX divertor configuration has recently been converted from an open to a closed geometry to inhibit the return of neutral gas from the divertor region to the main chamber. Since then, operation in a regime with high energy confinement in neutral beam heated discharges (ASDEX H-mode) has been routine over a wide range of operating conditions. These H-mode discharges are characterized by a sudden drop in divertor density and H/sub α/ emission and a spontaneous rise in main chamber plasma density during neutral beam injection. The confinement time is found to scale nearly linearly with plasma current, but it can be degraded due to either the presence of edge instabilities or heavy gas puffing. Detailed Thomson scattering temperature profiles show high values of Te near the plasma edge (approx. 450 eV) with sharp radial gradients (approx. 400 eV/cm) near the separatrix. Density profiles are broad and also exhibit steep gradients close to the separatrix

  19. Dry-out heat fluxes of falling film and low-mass flux upward-flow in heated tubes

    International Nuclear Information System (INIS)

    Koizumi, Yasuo; Ueda, Tatsuhiro; Matsuo, Teruyuki; Miyota, Yukio

    1998-01-01

    Dry-out heat fluxes were investigated experimentally for a film flow falling down on the inner surface of vertical heated-tubes and for a low mass flux forced-upward flow in the tubes using R 113. This work followed the study on those for a two-phase natural circulation system. For the falling film boiling, flow state observation tests were also performed, where dry-patches appearing and disappearing repeatedly were observed near the exit end of the heated section at the dry-out heat flux conditions. Relation between the dry-out heat flux and the liquid film flow rate is analyzed. The dry-out heat fluxes of the low mass flux upflow are expressed well by the correlation proposed in the previous work. The relation for the falling film boiling shows a similar trend to that for the upflow boiling, however, the dry-out heat fluxes of the falling film are much lower, approximately one third, than those of the upward flow. (author)

  20. Modelling of mitigation of the power divertor loading for the EU DEMO through Ar injection

    Science.gov (United States)

    Subba, Fabio; Aho-Mantila, Leena; Coster, David; Maddaluno, Giorgio; Nallo, Giuseppe F.; Sieglin, Bernard; Wenninger, Ronald; Zanino, Roberto

    2018-03-01

    In this paper we present a computational study on the divertor heat load mitigation through impurity injection for the EU DEMO. The study is performed by means of the SOLPS5.1 code. The power crossing the separatrix is considered fixed and corresponding to H-mode operation, whereas the machine operating condition is defined by the outboard mid-plane upstream electron density and the impurity level. The selected impurity for this study is Ar, based on its high radiation efficiency at SOL characteristic temperatures. We consider a conventional vertical target geometry for the EU DEMO and monitor target conditions for different operational points, considering as acceptability criteria the target electron temperature (≤5 eV to provide sufficiently low W sputtering rate) and the peak heat flux (below 5-10 MW m-2 to guarantee safe steady-state cooling conditions). Our simulations suggest that, neglecting the radiated power deposition on the plate, it is possible to satisfy the desired constraints. However, this requires an upstream density of the order of at least 50% of the Greenwald limit and a sufficiently high argon fraction. Furthermore, if the radiated power deposition is taken into account, the peak heat flux on the outer plate could not be reduced below 15 MW m-2 in these simulations. As these simulations do not take into account neutron loading, they strongly indicate that the vertical target divertor solution with a radiative front distributed along the divertor leg has a very marginal operational space in an EU DEMO sized reactor.

  1. A program to Evaluate the Erosion on the CFC tiles of the ITER Divertor

    International Nuclear Information System (INIS)

    DAgata, E.; Tivey, R.; Ogorodnikova, O.; Lowry, Ch.; Schlosser, J.

    2006-01-01

    The plasma-facing surfaces of the ITER divertor are armoured with tungsten in the upper part of the inner and outer vertical targets and carbon-fibre composite (CFC) in the lower part, the region where the scrape-off layer intercepts the divertor. The CFC in the form of a monoblock in the vertical target is the most loaded part of the plasma-facing surfaces, and hence it is subjected to high erosion and has a significant risk of failure. A program has been developed with the aim of understanding the impact on the erosion lifetime and on the probability of a critical heat flux event in the heat sink of a combination of two main effects: the material property variations (particularly pronounced in CFC) and the presence of joining defects. The software allows the evolution of the surface profile of the armour to be predicted and the margin on critical heat flux at the heat-sink-to-coolant interface to be estimated for a range of postulated defects, for start-of-life through to end-of-life of the component. In assessing erosion, the code takes account of geometry and sublimation, and physical and chemical erosion of the CFC armour. The code allows the computation of the effect of normal and off-normal (ELMs, etc.) operation. The incident angle (a glancing angle of a few degrees) of the particle and heat flux onto the target is taken into account. The program has been validated by comparison with analytical approximations and experimental data. The code has been developed in APDL language to operate inside a commercial and certificate finite element program such as ANSYS. (author)

  2. Current profile control and magnetohydrodynamic stability in Tore Supra discharges with edge-plasma control by the ergodic divertor

    International Nuclear Information System (INIS)

    Zabiego, M.; Friant, C.; Ghendrih, P.; Becoulet, M.; Bucalossi, J.; Saint-Laurent, F.

    1999-01-01

    Although ergodic divertors are primarily designed to control particle and heat fluxes at the plasma edge, they also happen to affect the MHD stability of tokamak discharges. On Tore Supra, the ergodic divertor has long been known to stabilize the m/n=2/1 tearing mode induced, for instance, by edge radiation and detachment processes, thus allowing safe high-current and high-density operations. More recently, though, in discharges where ergodic divertor operations were optimised relative to the control of the edge-plasma (i.e., with large divertor perturbation), a detrimental increase in the disruptiveness has been observed. The action that the ergodic divertor has on the MHD activity is interpreted in terms of a redistribution of the current profile. The latter results from a large increase in the edge resistivity, primarily induced by the degradation of the electron energy confinement in the ergodic layer. The possibility that a transport barrier develops in the vicinity of the separatrix strongly affects the considered modelling. (authors)

  3. Qualification and post-mortem characterization of tungsten mock-ups exposed to cyclic high heat flux loading

    Energy Technology Data Exchange (ETDEWEB)

    Pintsuk, G., E-mail: g.pintsuk@fz-juelich.de [Forschungszentrum Jülich GmbH, Euratom Association, D-52425 Jülich (Germany); Bobin-Vastra, I.; Constans, S. [AREVA NP PTCMI-F, Centre Technique, Fusion, F-71200 Le Creusot (France); Gavila, P. [Fusion for Energy, E-08019 Barcelona (Spain); Rödig, M. [Forschungszentrum Jülich GmbH, Euratom Association, D-52425 Jülich (Germany); Riccardi, B. [Fusion for Energy, E-08019 Barcelona (Spain)

    2013-10-15

    Highlights: • We characterize tungsten mono-block components after exposure to ITER relevant heat loads. • We qualify the manufacturing technology, i.e., hot isostatic pressing and hot radial pressing, and repair technologies. • We determine the microstructural influences, i.e., rod vs. plate material, on the damage evolution. • Needle like microstructures increase the risk of deep crack formation due to a limited fracture strength. -- Abstract: In order to evaluate the option to start the ITER operation with a full tungsten (W) divertor, high heat flux tests were performed in the electron beam facility FE200, Le Creusot, France. Thereby, in total eight small-scale and three medium-scale monoblock mock-ups produced with different manufacturing technologies and different tungsten grades were exposed to cyclic steady state heat loads. The applied power density ranges from 10 to 20 MW/m{sup 2} with a maximum of 1000 cycles at each particular loading step. Finally, on a reduced number of tiles, critical heat flux tests in the range of 30 MW/m{sup 2} were performed. Besides macroscopic and microscopic images of the loaded surface areas, detailed metallographic analyses were performed in order to characterize the occurring damages, i.e., crack formation, recrystallization, and melting. Thereby, the different joining technologies, i.e., hot radial pressing (HRP) vs. hot isostatic pressing (HIP) of tungsten to the Cu-based cooling tube, were qualified showing a higher stability and reproducibility of the HIP technology also as repair technology. Finally, the material response at the loaded top surface was found to be depending on the material grade, microstructural orientation, and recrystallization state of the material. These damages might be triggered by the application of thermal shock loads during electron beam surface scanning and not by the steady state heat load only. However, the superposition of thermal fatigue loads and thermal shocks as also expected

  4. Towards the procurement of the ITER divertor

    International Nuclear Information System (INIS)

    Merola, M.; Tivey, R.; Martin, A.; Pick, M.

    2006-01-01

    The procurement of the ITER divertor is planned to start in 2009. On the basis of the present common understanding of the sharing of the ITER components, the Japanese Participating Team (JAPT) will supply the outer vertical target, the Russian Federation (RF) PT the dome liner and will perform the high heat flux testing, the EU PT will supply the inner vertical targets and the cassette bodies, including final assembly of the divertor plasma-facing components (PFCs). The manufacturing of the PFCs of the ITER divertor represents a challenging endeavor due to the high technologies which are involved, and due to the unprecedented series production. To mitigate the associated risks, special arrangements need to be put in place prior to and during procurement to ensure quality and to keep to the time schedule. Before procurement can start, an ITER review of the qualification and production capability of each candidate PT is planned. Well in advance of the assumed start of the procurement, each PT which would like to contribute to the divertor PFC procurement, should first demonstrate its technical qualification to carry out the procurement with the required quality, and in an efficient and timely manner. Appropriate precautions, like subdivision of the procurement into stages, are also to be adopted during the procurement phase to mitigate the consequences of possible unexpected manufacturing problems. In preparation for writing the procurement specification for the vertical targets, the topic of setting acceptance criteria is also being addressed. This activity has the objective of defining workable acceptance criteria for the PFC armour joints. A complete set of analyses is also in progress to assess the latest design modifications against the design requirements. This task includes neutronic, shielding, thermo-mechanical and electromagnetic analyses. More than half of the ITER plasma parameters that must be measured and the related diagnostics are located in the

  5. VUV Spectroscopy in DIII-D Divertor

    International Nuclear Information System (INIS)

    Alkesh Punjabi; Nelson Jalufka

    2004-01-01

    The research carried out on this grant was motivated by the high power emission from the CIV doublet at 155 nm in the DIII-D divertor and to study the characteristics of the radiative divertor. The radiative divertor is designed to reduce the heat load to the target plates of the divertor by reducing the energy in the divertor plasma using upstream scrape-off-layer (SOL) radiation. In some cases, particularly in Partially Detached Divertor (PDD) operations, this emission accounts for more than 50% of the total radiation from the divertor. In PDD operation, produced by neutral gas injection, the particle flow to the target plate and the divertor temperature are significantly reduced. A father motivation was to study the CIV emission distribution in the lower, open divertor and the upper baffled divertor. Two Vacuum Ultra Violet Tangential viewing Television cameras (VUV TTV) were constructed and installed in the upper, baffled and the lower, open divertor. The images recorded by these cameras were then inverted to produce two-dimensional distributions of CIV in the poloidal plane. Results obtained in the project are summarized in this report

  6. Particle recirculation in the ergodic divertor of Tore Supra

    International Nuclear Information System (INIS)

    Gunn, J.P.; Azeoual, A.; Becoulet, M.

    1999-01-01

    The present paper addresses the issue of particle recirculation in discharges where low energy flux to ergodic divertor target plates is achieved, in highly radiating detached ohmic plasmas. Plasma temperature and particle flux are measured by flush-mounted probes in the divertor plates, and by an upstream fast scanning Mach probe. The scalings with core density of the ion flux and electron temperature are well described by the simple two-point model used in axisymmetric poloidal divertors. The detachment signature is a pressure drop that occurs when the edge temperature falls below 10 eV. The parallel ion flux gradient is always positive, indicating that recombination is unlikely to play an important role in detachment. Visible spectroscopy of a neutralizer plate shows that attainment of cold detached plasmas near the density limit coincides with an abrupt increase of fueling for both deuterium and impurities. A feedback algorithm based on real time Langmuir probe measurements has been developed to monitor detachment and avoid disruptions. (authors)

  7. Ion orbit modelling of ELM heat loads on ITER divertor vertical targets.

    Czech Academy of Sciences Publication Activity Database

    Gunn, J. P.; Carpentier-Chouchana, S.; Dejarnac, Renaud; Escourbiac, F.; Hirai, T.; Komm, Michael; Kukushkin, A.; Panayotis, S.; Pitts, R.A.

    2017-01-01

    Roč. 12, August (2017), s. 75-83 ISSN 2352-1791. [International Conference on Plasma Surface Interactions 2016, PSI2016 /22./. Roma, 30.05.2016-03.06.2016] Institutional support: RVO:61389021 Keywords : ITER * Divertor * ELM heat loads Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) http://www.sciencedirect.com/science/article/pii/S2352179116302745

  8. Two-dimensional impurity transport calculations for a high recycling divertor

    International Nuclear Information System (INIS)

    Brooks, J.N.

    1986-04-01

    Two dimensional analysis of impurity transport in a high recycling divertor shows asymmetric particle fluxes to the divertor plate, low helium pumping efficiency, and high scrapeoff zone shielding for sputtered impurities

  9. Thermal transients due to sweeping of the separatrix on the monoblock divertor concept for ITER

    International Nuclear Information System (INIS)

    Renda, V.; Papa, L.; Soria, A.

    1991-01-01

    The ITER divertor plate considered in the present study is the monoblock design option, consisting of an armour of CFC-SEP-Carb graphite tiles, crossed by the tubes of the water cooling system made in Mo-Re alloy. Preliminary steady-state calculations for a peak flux of 15 MW/m 2 showed that the allowable thickness to limit the maximum temperature to 1273 K (1000degC) is about 5 mm. This small value reduces the lifetime of the plate, due to the expected erosion rate, to an unacceptable value from the engineering standpoint. A sweeping of the separatrix has been proposed to reduce the erosion of the protective armour and to lessen the thermomechanical effects of the localized peak surface heat flux. A rotation of the null points of the separatrix of 30 mm radius with a frequency of 0.3 Hz for a surface heat flux of 15 MW/m 2 was assumed as nominal working condition. Several scenarios were considered as off-normal conditions: the loss of sweeping accident, the change in frequency from 0.3 to 0.1 Hz and the change of the peak of the surface heat flux from 15 to 30 MW/m 2 . The results related to the nominal condition show that a 16 mm thick armour could be allowed; this value should ensure an acceptable lifetime for the divertor plate. The loss of sweeping accident leads the surface temperature to reach about 2273 K in few seconds; the change in frequency raises the maximum temperature of 423 K, but its range doubles; the change in peak flux leads to a maximum temperature of about 2373 K. (author)

  10. Efficiency of water coolant for DEMO divertor

    International Nuclear Information System (INIS)

    Fetzer, Renate; Igitkhanov, Yuri; Bazylev, Boris

    2015-01-01

    Up to now, water-cooled divertor concepts have been developed for limited incident fluxes without taking into account transient power loadings. In this paper we analyzed the efficiency of water as a coolant for the particular PFC tungsten monoblock shield with a cooling tube made from Cu alloy (Cu OFHC) as a laminate adjacent to W and a low activation martensitic steel (Eurofer) as inner tube contacting the coolant. Thermal analysis is carried out by using the code MEMOS, which simulates W armour damage under the repetitive ELM heat loads. We consider cooling conditions which allow one to keep relatively high material temperatures (in the range 300–600 °C) thus minimizing Eurofer embrittlement under neutron irradiation. Expected DEMO I and DEMO II heat loads including type I ELMs are found to cause melting of the W surface during unmitigated ELMs. By mitigation of the ELMs melting of W is avoided. DEMO I operation under these conditions is save for cooling at water pressure 15.5 MPa and temperature 325 °C, while for DEMO II with mitigated ELMs the critical heat flux is exceeded and safe operation is not provided.

  11. Efficiency of water coolant for DEMO divertor

    Energy Technology Data Exchange (ETDEWEB)

    Fetzer, Renate, E-mail: renate.fetzer@kit.edu; Igitkhanov, Yuri; Bazylev, Boris

    2015-10-15

    Up to now, water-cooled divertor concepts have been developed for limited incident fluxes without taking into account transient power loadings. In this paper we analyzed the efficiency of water as a coolant for the particular PFC tungsten monoblock shield with a cooling tube made from Cu alloy (Cu OFHC) as a laminate adjacent to W and a low activation martensitic steel (Eurofer) as inner tube contacting the coolant. Thermal analysis is carried out by using the code MEMOS, which simulates W armour damage under the repetitive ELM heat loads. We consider cooling conditions which allow one to keep relatively high material temperatures (in the range 300–600 °C) thus minimizing Eurofer embrittlement under neutron irradiation. Expected DEMO I and DEMO II heat loads including type I ELMs are found to cause melting of the W surface during unmitigated ELMs. By mitigation of the ELMs melting of W is avoided. DEMO I operation under these conditions is save for cooling at water pressure 15.5 MPa and temperature 325 °C, while for DEMO II with mitigated ELMs the critical heat flux is exceeded and safe operation is not provided.

  12. Fluctuations measured by flush mounted versus proud divertor Langmuir probes - why are they different?

    Science.gov (United States)

    Garcia, O. E.; Kuang, A. Q.; Brunner, D.; Labombard, B.; Kube, R.

    2017-10-01

    A flush-mounted, toroidally-elongated, and field-aligned divertor `rail' Langmuir probe array was installed in Alcator C-Mod in 2015. This geometry is heat flux tolerant and effectively mitigates sheath expansion effects down to incident field line angles of 0.5 degree. Further complications have arisen that cannot be explained by sheath-expansion. In particular, the `rail' probe geometry measures significantly higher plasma fluctuation levels in the common flux region compared to traditional proud probes, whereas they are similar in the private flux zone. In some instances, the amplitudes of ion saturation current fluctuations normalized to the mean are a factor of 2 higher; probability distribution functions correspondingly record large amplitude events that are not seen by the proud probes. This discrepancy also appears to depend on divertor plasma regime. For example, fluctuations become similar near the strikepoint when the electron temperature is low. To ensure that these discrepancies were not due to perturbations caused by the voltage bias or currents collected by the probes, the two Langmuir probe systems were left to `float' and the fluctuation statistics analyzed. Yet, even in this non-perturbative situation, there exist clear differences in the fluctuation characteristics. The raises two questions: how does the probe geometry affect plasma fluctuations measurements and what are the true plasma fluctuations experienced by the divertor surface? Supported by USDoE awards DE-FC02-99ER54512.

  13. Resonant island divertor experiments on text

    International Nuclear Information System (INIS)

    deGrassie, J.S.; Evans, T.E.; Jackson, G.L.

    1988-09-01

    The first experimental tests of the resonant island divertor (RID) concept have been carried out on the Texas Experimental Tokamak (TEXT). Modular perturbation coils produce static resonant magnetic fields at the tokamak boundary. The resulting magnetic islands are used to guide heat and particle fluxes around a small scoop limiter head. An enhancement in the limiter collection efficiency over the nonisland operation, as evidenced by enhanced neutral density within the limiter head, of up to a factor of 4 is obtained. This enhancement is larger than one would expect given the measured magnitude of the cross-field particle transport in TEXT. It is proposed that electrostatic perturbations occur which enhance the ion convection rate around the islands. Preliminary experiments utilizing electron cyclotron heating (ECH) in conjunction with RID operation have also have been performed. 6 refs., 3 figs

  14. Qualification of high heat flux components: application to target elements of W7-X divertor

    International Nuclear Information System (INIS)

    Missirlian, M; Durocher, A; Grosman, A; Schlosser, J; Boscary, J; Escourbiac, F; Cismondi, F

    2007-01-01

    The development of actively cooled plasma-facing components (PFC) represents one of fusion's most challenging engineering efforts. In this frame, a high-quality bonding between the refractory armour and the heat sink is essential to ensure the heat removal capability and the thermal performances of PFC. Experience gained during manufacturing of Tore Supra actively cooled PFC led to the establishment of a qualification methodology and provided a large experience of acceptance criteria using an active infrared thermography (systeme d'acquisition de traitement infra-rouge, SATIR). This paper presents the application of this qualification process to the W7-X pre-series components, with the objective of assessing and defining workable acceptance criteria that enable reliable predictions of performance at the nominal heat flux requirements in W7-X. Finally, to check the reliability of the non-destructive examination (NDE) method by transient infrared thermography, the newly defined acceptance criteria were applied to W7-X pre-series target elements (batch no. 3). The SATIR results, benchmarked with HHF tests performed on the GLADIS ion beam facility were discussed to assess the ability to detect critical defects at the interface between tiles and heat sink

  15. Engineering studies for the installation of an axi-symmetric metallic divertor in Tore Supra

    International Nuclear Information System (INIS)

    Doceul, L.; Portafaix, C.; Bucalossi, J.; Saille, A.; Bertrand, B.; Lipa, M.; Missirlian, M.; Jiolat, G.; Samaille, F.; Soler, B.

    2011-01-01

    Tore Supra (TS) has been designed to operate using technologies that allow long plasma operation (a few minutes), by means of superconducting magnets and actively-cooled high heat flux plasma facing components (PFCs). Actively cooled tungsten PFC will be used in the baffle area of the first ITER divertor. In order to validate such a technology fully (industrial manufacturing, operation with long plasma duration), the implementation of a tungsten axi-symmetric divertor in the tokamak Tore Supra has been studied . With this second major upgrade, Tore Supra should be able to address the problematic of long plasma discharges with a metallic divertor. The proposed divertor is made up of two stainless steel casings containing a copper coil winding located at the top and bottom area of the vacuum vessel. These casings are firmly maintained by connection beams and protected by PFC. This paper describes the mechanical design of this major component and its integration in TS, the associated electromagnetic and thermomechanical analysis, the manufacturing issues and finally the integration of ITER representative PFCs.

  16. An operational non destructive examination for ITER divertor plasma facing components

    Energy Technology Data Exchange (ETDEWEB)

    Durocher, A.; Escourbiac, F.; Farjon, J.L.; Vignal, N.; Cismondi, F. [Association Euratom-CEA Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Merola, M. [ITER International Team, Cadarache, 13 - St Paul Lez Durance (France); Riccardi, B. [CEFDA CSU-Garching, Garching bei Munchen (Germany)

    2007-07-01

    Full text of publication follows: To meet the power exhaust - heat flux of 20 MW/m{sup 2} - requirements of Plasma Facing Components (PFCs) during plasma operation requires control of their thermal and mechanical integrity. As heat exhaust capability and lifetime of PFCs during in-situ operation are linked to the manufacturing quality, it is an absolute requirement to develop reliable nondestructive examination methods, in particular of the CFC-CuCrZr joint, throughout the manufacturing process. Within the framework of Tokamak Tore Supra upgrade, a pioneering activity has been developed to evaluate the capability of the PFC to be efficiently cooled. In 1998 a test bed - so called SATIR - based on the heat transient method was developed by the CEA and is used today as an inspection tool in order to guarantee the PFCs performances. The technical procurement plan of ITER Divertor targets stated that all Cu cast layers on CFC armour should be subjected to 100% thermographic examination. Each ITER Party should demonstrate its technical capability to carry out the PFC with the required cooling efficiently. The ITER Divertor PFCs pose new challenges especially for the mono-block CFC thickness, and the number of full scale units to be tested which is higher than on any existing or under construction fusion machine. The SATIR method as functional inspection has been identified as the basis test to decide upon the final acceptance of the Divertor PFCs. In order to increase the detection sensitivity of SATIR test bed, several possibilities have been assessed i) the increase of the convective heat transfer coefficient, which improved in a significant way the sensitivity of SATIR diagnostic on ITER components. ii) the installation of a digital infrared camera and the improvement of the thermal signal processing, has led to a considerable increase of performances iii) an innovative process based on spatial image autocorrelation will allow to localize the interlayer defect

  17. End loss analyzer system for measurements of plasma flux at the C-2U divertor electrode

    Energy Technology Data Exchange (ETDEWEB)

    Griswold, M. E., E-mail: mgriswold@trialphaenergy.com; Korepanov, S.; Thompson, M. C. [Tri Alpha Energy, P.O. Box 7010, Rancho Santa Margarita, California 92688 (United States)

    2016-11-15

    An end loss analyzer system consisting of electrostatic, gridded retarding-potential analyzers and pyroelectric crystal bolometers was developed to characterize the plasma loss along open field lines to the divertors of C-2U. The system measures the current and energy distribution of escaping ions as well as the total power flux to enable calculation of the energy lost per escaping electron/ion pair. Special care was taken in the construction of the analyzer elements so that they can be directly mounted to the divertor electrode. An attenuation plate at the entrance to the gridded retarding-potential analyzer reduces plasma density by a factor of 60 to prevent space charge limitations inside the device, without sacrificing its angular acceptance of ions. In addition, all of the electronics for the measurement are isolated from ground so that they can float to the bias potential of the electrode, 2 kV below ground.

  18. Manufacturing and testing of a copper/CFC divertor mock-up for JET

    International Nuclear Information System (INIS)

    Brossa, M.; Ciric, D.; Deksnis, E.; Falter, H.; Guerreschi, U.; Peacock, A.; Pick, M.; Rossi, M.; Shen, Y.; Zacchia, F.

    1995-01-01

    An actively cooled divertor is a possible option for future developments at The Joint European Torus (JET). A proof of principle actively cooled tile has been produced in order to qualify the relevant manufacturing technologies and the non destructive control processes. In this frame Ansaldo Ricerche (ARI) has been involved in the construction of a mock-up comprising 6 OFHC copper tubes for water cooling that are brazed to a plate made out of carbon fibre composite (CFC). The final objective was the high heat flux testing of the mock-up at JET in order to evaluate the general behaviour of the component under relevant operating conditions. The key point of the work was the realisation of a sound joint by adapting the expertise gained in ARI in previous R and D activities on brazing heterogeneous materials. Reliable methods for ultrasonic examinations of the pieces were also set up. For successful application to the JET pumped divertor a water-cooled CFC target plate must show surface temperatures of 2 . Furthermore, global hydraulic considerations specific to JET limit the system pressure to 0.7 MPa. In such a design, critical heat flux is not the key limit, rather the reliability of the CFC-copper joint in terms of extent of wetting. First tests in the neutral beam test bed at JET show an adequate response for fluxes up to 15 MW/m 2 . (orig.)

  19. The appearance and propagation of filaments in the private flux region in Mega Amp Spherical Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, J. R.; Fishpool, G. M.; Thornton, A. J. [CCFE, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Walkden, N. R. [York Plasma Institute, Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom)

    2015-09-15

    The transport of particles via intermittent filamentary structures in the private flux region (PFR) of plasmas in the MAST tokamak has been investigated using a fast framing camera recording visible light emission from the volume of the lower divertor, as well as Langmuir probes and IR thermography monitoring particle and power fluxes to plasma-facing surfaces in the divertor. The visible camera data suggest that, in the divertor volume, fluctuations in light emission above the X-point are strongest in the scrape-off layer (SOL). Conversely, in the region below the X-point, it is found that these fluctuations are strongest in the PFR of the inner divertor leg. Detailed analysis of the appearance of these filaments in the camera data suggests that they are approximately circular, around 1–2 cm in diameter, but appear more elongated near the divertor target. The most probable toroidal quasi-mode number is between 2 and 3. These filaments eject plasma deeper into the private flux region, sometimes by the production of secondary filaments, moving at a speed of 0.5–1.0 km/s. Probe measurements at the inner divertor target suggest that the fluctuations in the particle flux to the inner target are strongest in the private flux region, and that the amplitude and distribution of these fluctuations are insensitive to the electron density of the core plasma, auxiliary heating and whether the plasma is single-null or double-null. It is found that the e-folding width of the time-average particle flux in the PFR decreases with increasing plasma current, but the fluctuations appear to be unaffected. At the outer divertor target, the fluctuations in particle and power fluxes are strongest in the SOL.

  20. T-12 divertor experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bortnikov, A V; Brevnov, N N; Gerasimov, S N; Zhukovskii, V G; Kuznetsov, N V; Naftulin, S M; Pergament, V I; Khimchenko, L N [Gosudarstvennyj Komitet po Ispol' zovaniyu Atomnoj Ehnergii SSSR, Moscow. Inst. Atomnoj Ehnergii

    1981-01-01

    In designing tokamak devices and reactors, in the last few years, the use of elongated-cross-section plasma discharges has been proposed to improve the economic and physical parameters. Application of a quadrupole poloidal magnetic field necessary for sustaining the elongated discharge cross-section serves, in this case, to create the magnetic configuration of an axisymmetric poloidal divertor. To-day, the creation of such a combination, including an elongated plasma cross-section and a divertor and using the outer poloidal magnetic field coils, seems to be the most reasonable approach, from the point of view of design and technology. Such a divertor was produced and studied at the T-12 tokamak. A stable equilibrium configuration of a finger-ring tokamak with a divertor has been produced by superposing the magnetic fields of the plasma current, the external quadrupole coils and the copper shell currents; the reactor blanket can fulfil the function of the latter. It is shown that both a symmetric magnetic configuration with two divertors and a droplet configuration with a single divertor may be realized by controlling the plasma column position with respect to the equatorial plane. The stability of the plasma column against vertical displacement depends on this position and the distance between the separatrix points. Vertical instability stabilization has been observed. The divertor layer efficiently screens the plasma from the impurity influx from the wall and unloads the wall from particle and energy fluxes. The results obtained from the tokamak T-12 experiment have demonstrated the capability of a system with outer poloidal field coils and a copper shell providing an elongated-cross-section plasma column with poloidal divertors.

  1. Sensors for Metering Heat Flux Area Density and Metrological Equipment for the Heat Flux Density Measurement

    Science.gov (United States)

    Doronin, D. O.

    2018-04-01

    The demand in measuring and studies of heat conduction of various media is very urgent now. This article considers the problem of heat conduction monitoring and measurement in various media and materials in any industries and branches of science as well as metrological support of the heat flux measurement equipment. The main study objects are both the sensors manufactured and facilities onto which these sensors will be installed: different cladding structures of the buildings, awnings, rocket fairings, boiler units, internal combustion engines. The Company develops and manufactures different types of heat flux sensors: thermocouple, thin-film, heterogeneous gradient as well as metrological equipment for the gauging calibration of the heat flux density measurement. The calibration shall be performed using both referencing method in the unit and by fixed setting of the heat flux in the unit. To manufacture heterogeneous heat flux gradient sensors (HHFGS) the Company developed and designed a number of units: diffusion welding unit, HHFGS cutting unit. Rather good quality HHFGS prototypes were obtained. At this stage the factory tests on the equipment for the heat flux density measurement equipment are planned. A high-sensitivity heat flux sensor was produced, now it is tested at the Construction Physics Research Institute (Moscow). It became possible to create thin-film heat flux sensors with the sensitivity not worse than that of the sensors manufactured by Captec Company (France). The Company has sufficient premises to supply the market with a wide range of sensors, to master new sensor manufacture technologies which will enable their application range.

  2. Development of the armoring technique for ITER Divertor Dome

    Energy Technology Data Exchange (ETDEWEB)

    Litunovsky, Nikolay, E-mail: nlitunovsky@sintez.niiefa.spb.su [D.V. Efremov Reseasch Institute, 3, Doroga na Metallostroy, Saint Petersburg (Russian Federation); Alekseenko, Evgeny; Makhankov, Alexey; Mazul, Igor [D.V. Efremov Reseasch Institute, 3, Doroga na Metallostroy, Saint Petersburg (Russian Federation)

    2011-10-15

    This paper describes the current status of the technique for armoring of Plasma Facing Units (PFUs) of the ITER Divertor Dome with flat tungsten tiles planned for application at the procurement stage. Application of high-temperature vacuum brazing for armoring of High Heat Flux (HHF) plasma facing components was traditionally developed at the Efremov Institute and successfully tried out at the ITER R and D stage by manufacturing and HHF testing of a number of W- and Be-armored mock-ups . Nevertheless, the so-called 'fast brazing' technique successfully applied in the past was abandoned at the stage of manufacturing of the Dome Qualification Prototypes (Dome QPs), as it failed to retain the mechanical properties of CuCrZr heat sink of the substrate. Another problem was a substantially increased number of armoring tiles brazed onto one substrate. Severe ITER requirements for the joints quality have forced us to refuse from production of W/Cu joints by brazing in favor of casting. These modifications have allowed us to produce ITER Divertor Dome QPs with high-quality tungsten armor, which then passed successfully the HHF testing. Further preparation to the procurement stage is in progress.

  3. Design feasibility study of a divertor component reinforced with fibrous metal matrix composite laminate

    International Nuclear Information System (INIS)

    You, J.-H.

    2005-01-01

    Fibrous metal matrix composites possess advanced mechanical properties compared to conventional alloys. It is expected that the application of these composites to a divertor component will enhance the structural reliability. A possible design concept would be a system consisting of tungsten armour, copper composite interlayer and copper heat sink where the composite interlayer is locally inserted into the highly stressed domain near the bond interface. For assessment of the design feasibility of the composite divertor concept, a non-linear multi-scale finite element analysis was performed. To this end, a micro-mechanics algorithm was implemented into a finite element code. A reactor-relevant heat flux load was assumed. Focus was placed on the evolution of stress state, plastic deformation and ductile damage on both macro- and microscopic scales. The structural response of the component and the micro-scale stress evolution of the composite laminate were investigated

  4. Design feasibility study of a divertor component reinforced with fibrous metal matrix composite laminate

    Energy Technology Data Exchange (ETDEWEB)

    You, J.-H. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Boltzmannstr. 2, D-85748 Garching (Germany)]. E-mail: j.h.you@ipp.mpg.de

    2005-01-01

    Fibrous metal matrix composites possess advanced mechanical properties compared to conventional alloys. It is expected that the application of these composites to a divertor component will enhance the structural reliability. A possible design concept would be a system consisting of tungsten armour, copper composite interlayer and copper heat sink where the composite interlayer is locally inserted into the highly stressed domain near the bond interface. For assessment of the design feasibility of the composite divertor concept, a non-linear multi-scale finite element analysis was performed. To this end, a micro-mechanics algorithm was implemented into a finite element code. A reactor-relevant heat flux load was assumed. Focus was placed on the evolution of stress state, plastic deformation and ductile damage on both macro- and microscopic scales. The structural response of the component and the micro-scale stress evolution of the composite laminate were investigated.

  5. A high-recycle divertor for ITER [International Thermonuclear Experimental Reactor

    International Nuclear Information System (INIS)

    Werley, K.A.; Bathke, C.G.

    1988-01-01

    A coupled one-dimensional (axial/radial) edge-plasma model (SOLAR) has been used to investigate tradeoffs between collector-plate and edge-plasma conditions in a doublenull, open, high-recycle divertor (HRD) for a preliminary International Thermonuclear Experimental Reactor (ITER) design. A steady-state HRD produces in attractive high-density edge plasma (5 /times/ 10 19 m/sup /minus/3/) with sufficiently low plasma temperature (10-20eV) at a tungsten plat that the sheath-accelerated ions are below sputtering threshold energies. Manageable plate heat fluxes (3-6 MW/m 2 ) are achieved by positioning the plate poloidal cross section at a minimum angle of 15-30/degree/ with respect to flux surfaces. 6 refs., 9 figs

  6. Development of divertor simulation research in the GAMMA 10/PDX tandem mirror

    International Nuclear Information System (INIS)

    Nakashima, Y.; Sakamoto, M.; Yoshikawa, M.; Oki, K.; Takeda, H.; Ichimura, K.; Hosoi, K.; Hirata, M.; Ichimura, M.; Ikezoe, R.; Imai, T.; Kariya, T.; Katanuma, I.; Kohagura, J.; Minami, R.; Numakura, T.; Wang, X.; Iwamoto, M.; Hosoda, Y.; Asakura, Nobuyuki; Fukumoto, Masakatsu; Kubo, Hirotaka; Hatayama, A.; Hirooka, Y.; Masuzaki, S.; Sagara, A.; Shoji, M.; Kado, S.; Matsuura, H.; Nagata, S.; Shikama, T.; Nishino, N.; Ohno, N.; Tonegawa, A.; Ueda, Y.

    2014-10-01

    This paper describes the recent development of divertor simulation research towards the characterization and control of the detached plasma. In the end-mirror of large tandem mirror device GAMMA 10/PDX, additional ICRF heating experiments in the anchor-cells significantly increases the density in both the anchor and the central cells, which attained the highest particle flux up to 1.7×10 23 particles/s·m 2 at the end-mirror exit. Massive gas injection (H 2 and noble gases) to enhance the radiation cooling in divertor simulation experimental module (D-module) was performed and we have succeeded for the first time in achieving detachment of high temperature plasma equivalent to the SOL plasma of tokamaks by using linear device. A remarkable reduction of the electron temperature (from few tens eV to < 3 eV) on the target plate was successfully achieved associated with the strong reduction of particle and heat fluxes. Two-dimensional image of Hα emission in D-module observed with high-speed camera showed the bright emission in upstream region and strong reduction near the target plate. These results indicate radiation cooling and formation of detached plasma due to gas injection. It is also found that Xe gas is much effective on achieving detached plasma than Ar gas. Simultaneous injection of noble gas and hydrogen gas showed the most effective results on detached plasma generation, which indicates the effect of molecular activated recombination (MAR) processes. The above results will contribute to establishment of detached plasma control and clarification of radiation cooling mechanism towards the development of future divertor systems. (author)

  7. A computational study of operating regimes for poloidal divertors

    International Nuclear Information System (INIS)

    Petravic, M.; Heifetz, D.; Post, D.

    1982-01-01

    We have identified three theoretical operating regimes for poloidal divertors. These regimes are determined by the geometry of the divertor and the input energy and particle fluxes, and are characterized by the divertor plasma density and temperature. A fully self-consistent two-dimensional model for the plasma and neutral atom and molecule transport was used to study poloidal divertor operation. Extensions of our previous calculations important to this study were the inclusion of parallel electron and ion thermal conduction. We find that the key physics in divertor operation is the neutral recycling near the neutralizer plate. This can be parametrized by R = GAMMAsub(P)/GAMMAsub(O), the ratio of particle flux striking the neutralizer plate to the particle flux entering the divertor. Values of R approx. equal to 1 can be produced by large pumping rates near the neutralizer plates resulting in low neutral recycling and a high temperature, low density divertor plasma. By decreasing the pumping near the neutralizer plate, R can be raised to an intermediate value of 5-10, the plasma temperature lowered by the same factor, and the density raised by a factor of 10-30. In this regime, escape of the neutrals back to the main plasma is virtually blocked. By further restricting the pumping, R can be raised to twenty or more, thereby lowering the temperature by a factor of twenty or more and raising the density by a factor of ninety or more. Such high density regimes have been observed on D-III and appear to offer the most promise for impurity control and particle control on large reactor experiments such as INTOR or FED. In this paper, we explore the range 3 < R < 16. (orig.)

  8. Heat and particle transport of sol/divertor plasma in the W-shaped divertor on JT-60U

    International Nuclear Information System (INIS)

    Asakura, N.; Sakurai, S.; Hosogane, N.

    1999-01-01

    The plasma profile and parallel flow in the scrape-off layer (SOL) were systematically measured using Mach probes installed at the midplane and the divertor x-point. Quantitative evaluation of a parallel flow: naturally produced in a torus to keep the pressure constant along the field line, was consistent with the measurement. Geometry effects of the W-shaped divertor on the divertor plasma and particle recycling at the newly installed baffle plates were evaluated quantitatively using the edge plasma data. (author)

  9. Development of divertor remote maintenance system

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Nobukazu; Oka, Kiyoshi; Akou, Kentaro; Takiguchi, Yuji [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-04-01

    The ITER divertor is categorized as a scheduled maintenance component because of extreme heat and particle loads it is exposed to by plasma. It is also highly activated by 14 MeV neutrons. Reliable remote handling equipment and tools are required for divertor maintenance under intense gamma radiation. To facilitate remote maintenance, the divertor is segmented into 60 cassettes, and each cassette weighing about 25 tons and maintained and replaced through four maintenance ports each 90 degrees. Divertor cassettes must be transported toroidally and radially for replacement through maintenance ports. Remote handling involving cassette movers and carriers for toroidal and radial transport has been developed. Under the ITER R and D program, technology critical to divertor cassette maintenance is being developed jointly by Japan, E.U., and U.S. home teams. This paper summarizes divertor remote maintenance design and the status of technology development by the Japan Home Team. (author)

  10. Development of divertor remote maintenance system

    International Nuclear Information System (INIS)

    Takeda, Nobukazu; Oka, Kiyoshi; Akou, Kentaro; Takiguchi, Yuji

    1998-01-01

    The ITER divertor is categorized as a scheduled maintenance component because of extreme heat and particle loads it is exposed to by plasma. It is also highly activated by 14 MeV neutrons. Reliable remote handling equipment and tools are required for divertor maintenance under intense gamma radiation. To facilitate remote maintenance, the divertor is segmented into 60 cassettes, and each cassette weighing about 25 tons and maintained and replaced through four maintenance ports each 90 degrees. Divertor cassettes must be transported toroidally and radially for replacement through maintenance ports. Remote handling involving cassette movers and carriers for toroidal and radial transport has been developed. Under the ITER R and D program, technology critical to divertor cassette maintenance is being developed jointly by Japan, E.U., and U.S. home teams. This paper summarizes divertor remote maintenance design and the status of technology development by the Japan Home Team. (author)

  11. Comment on “Magnetic geometry and physics of advanced divertors: The X-divertor and the snowflake” [Phys. Plasmas 20, 102507 (2013)

    International Nuclear Information System (INIS)

    Ryutov, D. D.; Cohen, R. H.; Rognlien, T. D.; Soukhanovskii, V. A.; Umansky, M. V.

    2014-01-01

    In the recently published paper “Magnetic geometry and physics of advanced divertors: The X-divertor and the snowflake” [Phys. Plasmas 20, 102507 (2013)], the authors raise interesting and important issues concerning divertor physics and design. However, the paper contains significant errors: (a) The conceptual framework used in it for the evaluation of divertor “quality” is reduced to the assessment of the magnetic field structure in the outer Scrape-Off Layer. This framework is incorrect because processes affecting the pedestal, the private flux region and all of the divertor legs (four, in the case of a snowflake) are an inseparable part of divertor operation. (b) The concept of the divertor index focuses on only one feature of the magnetic field structure and can be quite misleading when applied to divertor design. (c) The suggestion to rename the divertor configurations experimentally realized on NSTX (National Spherical Torus Experiment) and DIII-D (Doublet III-D) from snowflakes to X-divertors is not justified: it is not based on comparison of these configurations with the prototypical X-divertor, and it ignores the fact that the NSTX and DIII-D poloidal magnetic field geometries fit very well into the snowflake “two-null” prescription

  12. Heat transfer and critical heat flux in a spiral flow in an asymmetrical heated tube

    International Nuclear Information System (INIS)

    Boscary, J.; Association Euratom-CEA, Centre d'Etudes Nucleaires de Cadarache, 13 - Saint-Paul-lez-Durance

    1997-03-01

    The design of plasma facing components is crucial for plasma performance in next fusion reactors. These elements will be submitted to very high heat flux. They will be actively water-cooled by swirl tubes in the subcooled boiling regime. High heat flux experiments were conducted in order to analyse the heat transfer and to evaluate the critical heat flux. Water-cooled mock-ups were one-side heated by an electron beam gun for different thermal-hydraulic conditions. The critical heat flux was detected by an original method based on the isotherm modification on the heated surface. The wall heat transfer law including forced convection and subcooled boiling regimes was established. Numerical calculations of the material heat transfer conduction allowed the non-homogeneous distribution of the wall temperature and of the wall heat flux to be evaluated. The critical heat flux value was defined as the wall maximum heat flux. A critical heat flux model based on the liquid sublayer dryout under a vapor blanket was established. A good agreement with test results was found. (author)

  13. Examination of W7-X target elements after high heat flux testing

    International Nuclear Information System (INIS)

    Missirlian, M.; Durocher, A.; Schlosser, J.; Greuner, H.; Schedler, B.

    2007-01-01

    Full text of publication follows: The target elements of Wendelstein 7-X (W7-X) divertor are designed to sustain a stationary heat flux of 10 MW/m 2 and to remove a maximum power load up to 100 kW. The plasma-facing material is made of CFC NB31 flat tiles bonded to a CuCrZr copper alloy water-cooled heat sink. Before launching the serial fabrication, pre-series activities aimed at qualifying the design, the manufacturing route, the relevant non-destructive examination (NDE) methods, and at defining the acceptance criteria for the serial production. High heat flux (HHF) testing is the central activity of this qualification phase and represents a fundamental tool to predict 'critical' defects assembling. Within the framework of this qualification activity, the reception tests performed in the transient infrared thermography test bed SATIR at CEA-Cadarache and HHF testing carried out in the ion beam facility GLADIS at IPP-Garching, exhibited some tiles with thermal inhomogeneities, which initiated and developed during high heat flux testing. Hence, studies were launched in order to better understand this behaviour during cyclic heat loading. This post testing examination was mainly focused on the interface between CFC flat tiles and CuCrZr heat sink to improve if necessary the current design. HHF thermal cycling tests at ∼10 MW/m 2 for 10 s pulse duration each, allowed to assess the performances of target elements and showed some tiles with hot spots close to the edge (stable or progressing). Finally, after the HHF experimental campaign, a comprehensive analysis of some tested elements was carried out by means of infrared thermography inspection SATIR and metallographic examinations. Afterwards correlations between the non destructive SATIR inspection, HHF testing GLADIS and metallographic observation were investigated to assess damage detection, to analyse defect propagation, and to adjust the acceptance criteria valuable for the serial production. This paper will

  14. Progress in the engineering design and assessment of the European DEMO first wall and divertor plasma facing components

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Thomas R., E-mail: tom.barrett@ukaea.uk [CCFE, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Ellwood, G.; Pérez, G.; Kovari, M.; Fursdon, M.; Domptail, F.; Kirk, S.; McIntosh, S.C.; Roberts, S.; Zheng, S. [CCFE, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Boccaccini, L.V. [KIT, INR, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); You, J.-H. [Max Planck Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Bachmann, C. [EUROfusion, PPPT, Boltzmann Str. 2, 85748 Garching (Germany); Reiser, J.; Rieth, M. [KIT, IAM, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Visca, E.; Mazzone, G. [ENEA, Unità Tecnica Fusione, ENEA C. R. Frascati, via E. Fermi 45, 00044 Frascati (Italy); Arbeiter, F. [KIT, INR, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Domalapally, P.K. [Research Center Rez, Hlavní 130, 250 68 Husinec – Řež (Czech Republic)

    2016-11-01

    Highlights: • The engineering of the plasma facing components for DEMO is an extreme challenge. • PFC overall requirements, methods for assessment and designs status are described. • Viable divertor concepts for 10 MW/m{sup 2} surface heat flux appear to be within reach. • The first wall PFC concept will need to vary poloidally around the wall. • First wall coolant, structural material and PFC topology are open design choices. - Abstract: The European DEMO power reactor is currently under conceptual design within the EUROfusion Consortium. One of the most critical activities is the engineering of the plasma-facing components (PFCs) covering the plasma chamber wall, which must operate reliably in an extreme environment of neutron irradiation and surface heat and particle flux, while also allowing sufficient neutron transmission to the tritium breeding blankets. A systems approach using advanced numerical analysis is vital to realising viable solutions for these first wall and divertor PFCs. Here, we present the system requirements and describe bespoke thermo-mechanical and thermo-hydraulic assessment procedures which have been used as tools for design. The current first wall and divertor designs are overviewed along with supporting analyses. The PFC solutions employed will necessarily vary around the wall, depending on local conditions, and must be designed in an integrated manner by analysis and physical testing.

  15. Use of EPICS and Python technology for the development of a computational toolkit for high heat flux testing of plasma facing components

    Energy Technology Data Exchange (ETDEWEB)

    Sugandhi, Ritesh, E-mail: ritesh@ipr.res.in; Swamy, Rajamannar, E-mail: rajamannar@ipr.res.in; Khirwadkar, Samir, E-mail: sameer@ipr.res.in

    2016-11-15

    Highlights: • An integrated approach to software development for computational processing and experimental control. • Use of open source, cross platform, robust and advanced tools for computational code development. • Prediction of optimized process parameters for critical heat flux model. • Virtual experimentation for high heat flux testing of plasma facing components. - Abstract: The high heat flux testing and characterization of the divertor and first wall components are a challenging engineering problem of a tokamak. These components are subject to steady state and transient heat load of high magnitude. Therefore, the accurate prediction and control of the cooling parameters is crucial to prevent burnout. The prediction of the cooling parameters is based on the numerical solution of the critical heat flux (CHF) model. In a test facility for high heat flux testing of plasma facing components (PFC), the integration of computations and experimental control is an essential requirement. Experimental physics and industrial control system (EPICS) provides powerful tools for steering controls, data simulation, hardware interfacing and wider usability. Python provides an open source alternative for numerical computations and scripting. We have integrated these two open source technologies to develop a graphical software for a typical high heat flux experiment. The implementation uses EPICS based tools namely IOC (I/O controller) server, control system studio (CSS) and Python based tools namely Numpy, Scipy, Matplotlib and NOSE. EPICS and Python are integrated using PyEpics library. This toolkit is currently under operation at high heat flux test facility at Institute for Plasma Research (IPR) and is also useful for the experimental labs working in the similar research areas. The paper reports the software architectural design, implementation tools and rationale for their selection, test and validation.

  16. Use of EPICS and Python technology for the development of a computational toolkit for high heat flux testing of plasma facing components

    International Nuclear Information System (INIS)

    Sugandhi, Ritesh; Swamy, Rajamannar; Khirwadkar, Samir

    2016-01-01

    Highlights: • An integrated approach to software development for computational processing and experimental control. • Use of open source, cross platform, robust and advanced tools for computational code development. • Prediction of optimized process parameters for critical heat flux model. • Virtual experimentation for high heat flux testing of plasma facing components. - Abstract: The high heat flux testing and characterization of the divertor and first wall components are a challenging engineering problem of a tokamak. These components are subject to steady state and transient heat load of high magnitude. Therefore, the accurate prediction and control of the cooling parameters is crucial to prevent burnout. The prediction of the cooling parameters is based on the numerical solution of the critical heat flux (CHF) model. In a test facility for high heat flux testing of plasma facing components (PFC), the integration of computations and experimental control is an essential requirement. Experimental physics and industrial control system (EPICS) provides powerful tools for steering controls, data simulation, hardware interfacing and wider usability. Python provides an open source alternative for numerical computations and scripting. We have integrated these two open source technologies to develop a graphical software for a typical high heat flux experiment. The implementation uses EPICS based tools namely IOC (I/O controller) server, control system studio (CSS) and Python based tools namely Numpy, Scipy, Matplotlib and NOSE. EPICS and Python are integrated using PyEpics library. This toolkit is currently under operation at high heat flux test facility at Institute for Plasma Research (IPR) and is also useful for the experimental labs working in the similar research areas. The paper reports the software architectural design, implementation tools and rationale for their selection, test and validation.

  17. Design analysis of the ITER divertor

    International Nuclear Information System (INIS)

    Samuelli, G.; Marin, A.; Roccella, M.; Lucca, F.; Merola, M.; Riccardi, B.; Petrizzi, L.; Villari, R.

    2007-01-01

    The divertor is one of the most challenging components of the ITER machine. Its function is to reduce the impurity in the plasma and consists essentially of two parts: the plasma facing components (PFCs) and a massive support structure called the cassette body (CB). Considerable R and D effort (developed by EFDA CSU GARCHING and the ITER International Team together with the EU Associations and the EU Industries) has been spent in designing divertor components capable of withstanding the expected electromagnetic (EM) loads and to take into account the latest ITER design conditions. In support of such efforts extensive and very detailed Neutronic, Thermal, EM and Structural analyses have been performed. A summary of the analyses performed will be presented. One of the main result is a typical exercise of integration between the different kind of analyses and the importance of keeping the consistency between the different assumptions and simplifications. The models used for the numerical analyses include a detailed geometrical description of the CB, the inlet, outlet hydraulic manifolds, the CB to vacuum vessel locking system and three configurations of the PFU. The effect of electrical bridging, both in poloidal and toroidal direction, of the PFU castellation, due to a possible melting at the W mono-block or tiles, occurring during the plasma disruptions, has been analyzed. For all these configurations 2 VDE scenarios including the effect of the Toroidal Field Variation and the HaloCurrent with the related out of plane induced EM forces have been extensively analyzed and a detailed poloidal and radial distribution of the nuclear heating has been used for the neutronic flux on the divertor components. The aim of this activity is to produce a comprehensive design and assessment of the ITER divertor via: -The estimation of the neutronic heat deposition and shielding capability; -The calculation of the related thermal and mechanical effects and the comparison of the

  18. Design analysis of the ITER divertor

    Energy Technology Data Exchange (ETDEWEB)

    Samuelli, G.; Marin, A.; Roccella, M.; Lucca, F. [L.T. Calcoli SaS, Merate (Lecco) (Italy); Merola, M. [ITER Team, Cadarache (France); Riccardi, B. [EFDA CSU Garching (Germany); Petrizzi, L.; Villari, R. [CRE ENEA sulla Fusione Frascati, Roma (Italy)

    2007-07-01

    The divertor is one of the most challenging components of the ITER machine. Its function is to reduce the impurity in the plasma and consists essentially of two parts: the plasma facing components (PFCs) and a massive support structure called the cassette body (CB). Considerable R and D effort (developed by EFDA CSU GARCHING and the ITER International Team together with the EU Associations and the EU Industries) has been spent in designing divertor components capable of withstanding the expected electromagnetic (EM) loads and to take into account the latest ITER design conditions. In support of such efforts extensive and very detailed Neutronic, Thermal, EM and Structural analyses have been performed. A summary of the analyses performed will be presented. One of the main result is a typical exercise of integration between the different kind of analyses and the importance of keeping the consistency between the different assumptions and simplifications. The models used for the numerical analyses include a detailed geometrical description of the CB, the inlet, outlet hydraulic manifolds, the CB to vacuum vessel locking system and three configurations of the PFU. The effect of electrical bridging, both in poloidal and toroidal direction, of the PFU castellation, due to a possible melting at the W mono-block or tiles, occurring during the plasma disruptions, has been analyzed. For all these configurations 2 VDE scenarios including the effect of the Toroidal Field Variation and the HaloCurrent with the related out of plane induced EM forces have been extensively analyzed and a detailed poloidal and radial distribution of the nuclear heating has been used for the neutronic flux on the divertor components. The aim of this activity is to produce a comprehensive design and assessment of the ITER divertor via: -The estimation of the neutronic heat deposition and shielding capability; -The calculation of the related thermal and mechanical effects and the comparison of the

  19. Numerical Calculation of the Peaking Factor of a Water-Cooled W/Cu Monoblock for a Divertor

    International Nuclear Information System (INIS)

    Han Le; Chang Haiping; Zhang Jingyang; Xu Tiejun

    2015-01-01

    In order to accurately predict the incident critical heat flux (ICHF, the heat flux at the heated surface when CHF occurs) of a water-cooled W/Cu monoblock for a divertor, the exact knowledge of its peaking factors (f p ) under one-sided heating conditions with different design parameters is a key issue. In this paper, the heat conduction in the solid domain of a water-cooled W/Cu monoblock is calculated numerically by assuming the local heat transfer coefficients (HTC) of the cooling wall to be functions of the local wall temperature, so as to obtain f p . The reliability of the calculation method is validated by an experimental example result, with the maximum error of 2.1% only. The effects of geometric and flow parameters on the f p of a water-cooled W/Cu monoblock are investigated. Within the scope of this study, it is shown that the f p increases with increasing dimensionless W/Cu monoblock width and armour thickness (the shortest distance between the heated surface and Cu layer), and the maximum increases are 43.8% and 22.4% respectively. The dimensionless W/Cu monoblock height and Cu thickness have little effect on f p . The increase of Reynolds number and Jakob number causes the increase of f p , and the maximum increases are 6.8% and 9.6% respectively. Based on the calculated results, an empirical correlation on peaking factor is obtained via regression. These results provide a valuable reference for the thermal-hydraulic design of water-cooled divertors. (paper)

  20. Moving Divertor Plates in a Tokamak

    International Nuclear Information System (INIS)

    Zweben, S.J.; Zhang, H.

    2009-01-01

    Moving divertor plates could help solve some of the problems of the tokamak divertor through mechanical ingenuity rather than plasma physics. These plates would be passively heated on each pass through the tokamak and cooled and reprocessed outside the tokamak. There are many design options using varying plate shapes, orientations, motions, coatings, and compositions

  1. Moving Divertor Plates in a Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    S.J. Zweben, H. Zhang

    2009-02-12

    Moving divertor plates could help solve some of the problems of the tokamak divertor through mechanical ingenuity rather than plasma physics. These plates would be passively heated on each pass through the tokamak and cooled and reprocessed outside the tokamak. There are many design options using varying plate shapes, orientations, motions, coatings, and compositions.

  2. Fracture mechanical analysis of tungsten armor failure of a water-cooled divertor target

    Energy Technology Data Exchange (ETDEWEB)

    Li, Muyuan; Werner, Ewald [Lehrstuhl für Werkstoffkunde und Werkstoffmechanik, Technische Universität München, Boltzmannstr. 15, 85748 Garching (Germany); You, Jeong-Ha, E-mail: you@ipp.mpg.de [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, 85748 Garching (Germany)

    2014-11-15

    Highlights: • The FEM-based VCE method and XFEM were employed for computing K{sub I} (or J-integral) and predicting progressive cracking, respectively. • The most probable pattern of crack formation is radial cracking in the tungsten armor block. • The most probable site of cracking is the upper interfacial region of the tungsten armor block adjacent to the top position of the copper interlayer. • The initiation of a major crack becomes likely, only when the strength of tungsten armor block is significantly reduced from its original strength. - Abstract: The inherent brittleness of tungsten at low temperature and the embrittlement by neutron irradiation are its most critical weaknesses for fusion applications. In the current design of the ITER and DEMO divertor, the high heat flux loads during the operation impose a strong constraint on the structure–mechanical performance of the divertor. Thus, the combination of brittleness and the thermally induced stress fields due to the high heat flux loads raises a serious reliability issue in terms of the structural integrity of tungsten armor. In this study, quantitative estimates of the vulnerability of the tungsten monoblock armor cracking under stationary high heat flux loads are presented. A comparative fracture mechanical investigation has been carried out by means of two different types of computational approaches, namely, the extended finite element method (XFEM) and the finite element method (FEM)-based virtual crack tip extension (VCE) method. The fracture analysis indicates that the most probable pattern of crack formation is radial cracking in the tungsten armor starting from the interface to tube and the most probable site of cracking is the upper interfacial region of the tungsten armor adjacent to the top position of the copper interlayer. The strength threshold for crack initiation and the high heat flux load threshold for crack propagation are evaluated based on XFEM simulations and computations

  3. Plasma facing components integration studies for the WEST divertor

    Energy Technology Data Exchange (ETDEWEB)

    Ferlay, Fabien, E-mail: fabien.ferlay@cea.fr; Missirlian, Marc; Guilhem, Dominique; Firdaouss, Mehdi; Richou, Marianne; Doceul, Louis; Faisse, Frédéric; Languille, Pascal; Larroque, Sébastien; Martinez, André; Proust, Maxime; Louison, Céphise; Jeanne, Florian; Saille, Alain; Samaille, Frank; Verger, Jean-Marc; Bucalossi, Jérôme

    2015-10-15

    Highlights: • The divertor PFU integration has been studied regarding existing environment. • Magnetic, electric, thermal, hydraulic, mechanical loads and assembly are considered. - Abstract: In the context of the Tokamak Tore-Supra evolution, the CEA aims at transforming it into a test bench for ITER actively cooled tungsten (ACW) plasma facing components (PFC). This project named WEST (Tungsten Environment in Steady state Tokamak) is especially focused on the divertor target. The modification of the machine, by adding two axisymmetric divertors will make feasible an H-mode with an X-point close to the lower divertor. This environment will allow exposing the divertor ACW components up to 20 MW/m{sup 2} heat flux during long pulse. These specifications are well suited to test the ITER-like ACW target elements, respecting the ITER design. One challenge in such machine evolution is to integrate components in an existing vacuum vessel in order to obtain the best achievable performance. This paper deals with the design integration of ITER ACW target elements into the WEST environment considering magnetic, electric, thermal and mechanical loads. The feasibility of installation and maintenance has to be strongly considered as these PFC could be replaced several times. The ports size allows entering a 30° sector of pre-installed tungsten targets which will be plugged as quickly and easily as possible. The main feature of steady state operation is the active cooling, which leads to have many embedded cooling channels and bulky pipes on the PFC module including many connections and sealings between vacuum and water channels. The 30° sector design is now finalized regarding the ITER ACW elements specifications. No major modifications are expected.

  4. Snowflake divertor plasmas on TCV

    International Nuclear Information System (INIS)

    Piras, F; Coda, S; Furno, I; Moret, J-M; Sauter, O; Turri, G; Bencze, A; Duval, B P; Felici, F; Pochelon, A; Zucca, C; Pitts, R A; Tal, B

    2009-01-01

    Starting from a standard single null X-point configuration, a second order null divertor (snowflake (SF)) has been successfully created on the Tokamak a Configuration Variable (TCV) tokamak. The magnetic properties of this innovative configuration have been analysed and compared with a standard X-point configuration. For the SF divertor, the connection length and the flux expansion close to the separatrix exceed those of the standard X-point by more than a factor of 2. The magnetic shear in the plasma edge is also larger for the SF configuration.

  5. EMC3-EIRENE modeling of toroidally-localized divertor gas injection experiments on Alcator C-Mod

    Energy Technology Data Exchange (ETDEWEB)

    Lore, J.D., E-mail: lorejd@ornl.gov [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Reinke, M.L. [York Plasma Institute, Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); LaBombard, B. [Plasma Science and Fusion Center, MIT, Cambridge, MA 02139 (United States); Lipschultz, B. [York Plasma Institute, Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); Churchill, R.M. [Plasma Science and Fusion Center, MIT, Cambridge, MA 02139 (United States); Pitts, R.A. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Feng, Y. [Max Planck Institute for Plasma Physics, Greifswald (Germany)

    2015-08-15

    Experiments on Alcator C-Mod with toroidally and poloidally localized divertor nitrogen injection have been modeled using the three-dimensional edge transport code EMC3-EIRENE to elucidate the mechanisms driving measured toroidal asymmetries. In these experiments five toroidally distributed gas injectors in the private flux region were sequentially activated in separate discharges resulting in clear evidence of toroidal asymmetries in radiated power and nitrogen line emission as well as a ∼50% toroidal modulation in electron pressure at the divertor target. The pressure modulation is qualitatively reproduced by the modeling, with the simulation yielding a toroidal asymmetry in the heat flow to the outer strike point. Toroidal variation in impurity line emission is qualitatively matched in the scrape-off layer above the strike point, however kinetic corrections and cross-field drifts are likely required to quantitatively reproduce impurity behavior in the private flux region and electron temperatures and densities directly in front of the target.

  6. Atomic and molecular processes in JT-60U divertor plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Takenaga, H.; Shimizu, K.; Itami, K. [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment] [and others

    1997-01-01

    Atomic and molecular data are indispensable for the understanding of the divertor characteristics, because behavior of particles in the divertor plasma is closely related to the atomic and molecular processes. In the divertor configuration, heat and particles escaping from the main plasma flow onto the divertor plate along the magnetic field lines. In the divertor region, helium ash must be effectively exhausted, and radiation must be enhanced for the reduction of the heat load onto the divertor plate. In order to exhaust helium ash effectively, the difference between behavior of neutral hydrogen (including deuterium and tritium) and helium in the divertor plasma should be understood. Radiation from the divertor plasma generally caused by the impurities which produced by the erosion of the divertor plate and/or injected by gas-puffing. Therefore, it is important to understand impurity behavior in the divertor plasma. The ions hitting the divertor plate recycle through the processes of neutralization, reflection, absorption and desorption at the divertor plates and molecular dissociation, charge-exchange reaction and ionization in the divertor plasma. Behavior of hydrogen, helium and impurities in the divertor plasmas can not be understood without the atomic and molecular data. In this report, recent results of the divertor study related to the atomic and molecular processes in JT-60U were summarized. Behavior of neural deuterium and helium was discussed in section 2. In section 3, the comparisons between the modelling of the carbon impurity transport and the measurements of C II and C IV were discussed. In section 4, characteristics of the radiative divertor using Ne puffing were reported. The new diagnostic method for the electron density and temperature in the divertor plasmas using the intensity ratios of He I lines was described in section 5. (author)

  7. Conceptual design studies for the European DEMO divertor: Rationale and first results

    International Nuclear Information System (INIS)

    You, J.H.; Mazzone, G.; Visca, E.; Bachmann, Ch.; Autissier, E.; Barrett, T.; Cocilovo, V.; Crescenzi, F.; Domalapally, P.K.; Dongiovanni, D.; Entler, S.; Federici, G.; Frosi, P.; Fursdon, M.; Greuner, H.; Hancock, D.; Marzullo, D.; McIntosh, S.; Müller, A.V.; Porfiri, M.T.

    2016-01-01

    Highlights: • A brief overview is given on the overall R&D activities of the work package Divertor which is a project of the EUROfusion Consortium. • The rationale of the hydraulic, thermal and structural design scheme is described. • The first results obtained for the preliminary DEMO divertor cassette model are presented. - Abstract: In the European fusion roadmap, reliable power handling has been defined as one of the most critical challenges for realizing a commercially viable fusion power. In this context, the divertor is the key in-vessel component, as it is responsible for power exhaust and impurity removal for which divertor target is subjected to very high heat flux loads. To this end, an integrated R&D project was launched in the EUROfusion Consortium in order to deliver a holistic conceptual design solution together with the core technologies for the entire divertor system of a DEMO reactor. The work package ‘Divertor’ consists of two project areas: ‘Cassette design and integration’ and ‘Target development’. The essential mission of the project is to develop and verify advanced design concepts and the required technologies for a divertor system being capable of meeting the physical and system requirements defined for the next-generation European DEMO reactor. In this contribution, a brief overview is presented of the works from the first project year (2014). Focus is put on the loads specification, design boundary conditions, materials requirements, design approaches, and R&D strategy. Initial ideas and first estimates are presented.

  8. Conceptual design studies for the European DEMO divertor: Rationale and first results

    Energy Technology Data Exchange (ETDEWEB)

    You, J.H., E-mail: you@ipp.mpg.de [Max Planck Institute for Plasma Physics, Boltzmann Str. 2, 85748 Garching (Germany); Mazzone, G.; Visca, E. [ENEA, Unità Tecnica Fusione, ENEA C. R. Frascati, via E. Fermi 45, 00044 Frascati (Italy); Bachmann, Ch. [EUROfusion PMU, c/o IPP, Boltzmann Str. 2, 85748 Garching (Germany); Autissier, E. [CEA, IRFM, F-13108 Saint Paul Lez Durance (France); Barrett, T. [CCFE, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Cocilovo, V.; Crescenzi, F. [ENEA, Unità Tecnica Fusione, ENEA C. R. Frascati, via E. Fermi 45, 00044 Frascati (Italy); Domalapally, P.K. [Research Cnter Rez, Hlavní 130, 250 68 Husinec–Řež (Czech Republic); Dongiovanni, D. [ENEA, Unità Tecnica Fusione, ENEA C. R. Frascati, via E. Fermi 45, 00044 Frascati (Italy); Entler, S. [Institute of Plasma Physics CAS, Za Slovankou 3, 182 00 Praha 8 (Czech Republic); Federici, G. [EUROfusion PMU, c/o IPP, Boltzmann Str. 2, 85748 Garching (Germany); Frosi, P. [ENEA, Unità Tecnica Fusione, ENEA C. R. Frascati, via E. Fermi 45, 00044 Frascati (Italy); Fursdon, M. [CCFE, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Greuner, H. [Max Planck Institute for Plasma Physics, Boltzmann Str. 2, 85748 Garching (Germany); Hancock, D. [CCFE, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Marzullo, D. [CREATE, University of Naples Federico II, P.le Tecchio 80, 80125 Napoli (Italy); McIntosh, S. [CCFE, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Müller, A.V. [Max Planck Institute for Plasma Physics, Boltzmann Str. 2, 85748 Garching (Germany); Porfiri, M.T. [ENEA, Unità Tecnica Fusione, ENEA C. R. Frascati, via E. Fermi 45, 00044 Frascati (Italy); and others

    2016-11-01

    Highlights: • A brief overview is given on the overall R&D activities of the work package Divertor which is a project of the EUROfusion Consortium. • The rationale of the hydraulic, thermal and structural design scheme is described. • The first results obtained for the preliminary DEMO divertor cassette model are presented. - Abstract: In the European fusion roadmap, reliable power handling has been defined as one of the most critical challenges for realizing a commercially viable fusion power. In this context, the divertor is the key in-vessel component, as it is responsible for power exhaust and impurity removal for which divertor target is subjected to very high heat flux loads. To this end, an integrated R&D project was launched in the EUROfusion Consortium in order to deliver a holistic conceptual design solution together with the core technologies for the entire divertor system of a DEMO reactor. The work package ‘Divertor’ consists of two project areas: ‘Cassette design and integration’ and ‘Target development’. The essential mission of the project is to develop and verify advanced design concepts and the required technologies for a divertor system being capable of meeting the physical and system requirements defined for the next-generation European DEMO reactor. In this contribution, a brief overview is presented of the works from the first project year (2014). Focus is put on the loads specification, design boundary conditions, materials requirements, design approaches, and R&D strategy. Initial ideas and first estimates are presented.

  9. An Asdex-type divertor for ITER

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1989-01-01

    An Asdex-type local divertor is proposed for ITER consisting of a copper poloidal field coil adjacent to the plasma. Estimates indicate that the power consumption is acceptable. Advantages would be a much reduced heat load not very sensitive to magnetic perturbations. A disadvantage is the finite lifetime under neutron bombardment that would require periodic replacement of the divertor coils in a reactor, but probably not in ITER because of its limited fluence. Another disadvantage would be poorer blanket coverage unless the divertor coil itself incorporates breeding material. 3 figs

  10. Damage evaluation under thermal fatigue of a vertical target full scale component for the ITER divertor

    International Nuclear Information System (INIS)

    Missirlian, M.; Escourbiac, F.; Merola, M.; Durocher, A.; Bobin-Vastra, I.; Schedler, B.

    2007-01-01

    An extensive development programme has been carried out in the EU on high heat flux components within the ITER project. In this framework, a Full Scale Vertical Target (VTFS) prototype was manufactured with all the main features of the corresponding ITER divertor design. The fatigue cycling campaign on CFC and W armoured regions, proved the capability of such a component to meet the ITER requirements in terms of heat flux performances for the vertical target. This paper discusses thermographic examination and thermal fatigue testing results obtained on this component. The study includes thermal analysis, with a tentative proposal to evaluate with finite element approach the location/size of defects and the possible propagation during fatigue cycling

  11. Erosion of newly developed CFCs and Be under disruption heat loads

    Science.gov (United States)

    Nakamura, K.; Akiba, M.; Araki, M.; Dairaku, M.; Sato, K.; Suzuki, S.; Yokoyama, K.; Linke, J.; Duwe, R.; Bolt, H.; Roedig, M.

    1996-10-01

    An evaluation of the erosion under disruption heat loads is very important to the lifetime prediction of divertor armour tiles of next fusion devices such as ITER. In particular, erosion data on CFCs (carbon fiber reinforced composites) and beryllium (Be) as the armour materials is urgently required in the ITER design. For CFCs, high heat flux experiments on the newly developed CFCs with high thermal conductivity have been performed under the heat flux of around 800-2000 MW/m 2 and the pulse length of 2-5 ms in JAERI electron beam irradiation systems (JEBIS). As a result, the weight losses of B 4C doped CFCs after heating were almost same to those of the non doped CFC up to 5 wt% boron content. For Be, we have carried out our first disruption experiments on S65/C grade Be specimens in the Juelich divertor test facility in hot cells (JUDITH) facility as a frame work of the J—EU collaboration. The heating conditions were heat loads of 1250-5000 MW/m 2 for 2-8 ms, and the heated area was 3 × 3 mm 2. As a result, the protuberances of the heated area of Be were observed under the lower heat flux.

  12. Erosion of newly developed CFCs and Be under disruption heat loads

    International Nuclear Information System (INIS)

    Nakamura, K.; Duwe, R.; Bolt, H.; Roedig, M.

    1996-01-01

    An evaluation of the erosion under disruption heat loads is very important to the lifetime prediction of divertor armour tiles of next fusion devices such as ITER. In particular, erosion data on CFCs (carbon fiber reinforced composites) and beryllium (Be) as the armour materials is urgently required in the ITER design. For CFCs, high heat flux experiments on the newly developed CFCs with high thermal conductivity have been performed under the heat flux of around 800-2000 MW/m 2 and the pulse length of 2-5 ms in JAERI electron beam irradiation systems (JEBIS). As a result, the weight losses of B 4 C doped CFCs after heating were almost same to those of the non doped CFC up to 5 wt% boron content. For Be, we have carried out our first disruption experiments on S65/C grade Be specimens in the Juelich divertor test facility in hot cells (JUDITH) facility as a frame work of the J-EU collaboration. The heating conditions were heat loads of 1250-5000 MW/m 2 for 2-8 ms, and the heated area was 3 x 3 mm 2 . As a result, the protuberances of the heated area of Be were observed under the lower heat flux. (orig.)

  13. Comparative divertor-transport study for helical devices

    International Nuclear Information System (INIS)

    Feng, Y.; Sardei, F.; Kobayashi, M.

    2008-10-01

    Using the island divertors (ID) of W7-AS and W7-X and the helical divertor (HD) of LHD as examples, the paper presents a comparative divertor transport study for three typical helical devices of different machine-size following two distinct divertor concepts, aiming at identifying common physics issues/effects for mutual validation and combined studies. Based on EMC3/EIRENE simulations supported by experimental results, the paper first reviews and compares the essential transport features of the W7-AS ID and the LHD HD in order to build a base and framework for a predictive study of W7-X. Revealed is the fundamental role of the low-order magnetic islands in both divertor concepts. Preliminary EMC3/EIRENE simulation results for W7-X are presented and discussed with respect to W7-AS and LHD in order to show how the individual field and divertor topologies affect the divertor transport and performance. For instance, a high recycling regime which is absent from W7-AS and LHD is expected for W7-X. Topics addressed are restricted to the basic function elements of a divertor such as particle flux enhancement and impurity retention. In particular, the divertor function on reducing the influx of intrinsic impurities is examined for all the three devices under different divertor plasma conditions. Special attention is paid to examining the island screening potential of intrinsic impurities which has been predicted for all the three devices under high divertor collisionality conditions. The results are discussed in conjunction with the experimental observations for high density divertor plasmas in W7-AS and LHD. (author)

  14. Experience gained with the 3D machining of the W7-X HHF divertor target elements

    International Nuclear Information System (INIS)

    Junghanns, P.; Boscary, J.; Peacock, A.

    2015-01-01

    Highlights: • The Wendelstein 7-X surface of the actively cooled divertor is built up of 890 individually 3D machined target elements. • To date 300 target elements have been 3D machined with an accuracy of ±0.015 mm. • Copper discovered on the surface of few elements is no risk to operation. - Abstract: The high heat flux (HHF) divertor of W7-X consists of 100 target modules assembled from 890 actively water-cooled target elements protected with CFC tiles. The divertor surface will be built up of individually 3D machined target elements with 89 individual element types. To date 300 of the 890 target elements have been 3D machined with a very good accuracy. To achieve this successful result, a prototyping phase has been conducted to qualify the manufacturing route and to define the acceptance criteria with measures taken to minimize the risk of unacceptable damage during the manufacturing. After the 3D-machining, during the incoming inspection, copper infiltration from the interface between the CFC tiles and the CuCrZr heat sink to the plasma facing surface was detected in a small number of elements.

  15. Heat transfer and critical heat flux in a asymmetrically heated tube helicoidal flow; Transfert thermique et flux critique dans un ecoulement helicoidal en tube chauffe asymetriquement

    Energy Technology Data Exchange (ETDEWEB)

    Boscary, J

    1995-10-01

    The design of plasma facing components is crucial for plasma performance in next fusion reactors. These elements will be submitted to very high heat flux. They will be actively water-cooled by swirl tubes in the subcooled boiling regime. High heat flux experiments were conducted in order to analyse the heat transfer and to evaluate the critical heat flux. Water-cooled mock-ups were one-side heated by an electron beam gun for different thermal-hydraulic conditions. The critical heat flux was detected by an original method based on the isotherm modification on the heated surface. The wall heat transfer law including forced convection and subcooled boiling regimes was established. Numerical calculations of the material heat transfer conduction allowed the non-homogeneous distribution of the wall temperature and of the wall heat flux to be evaluated. The critical heat flux value was defined as the wall maximum heat flux. A critical heat flux model based on the liquid sublayer dryout under a vapor blanket was established. A good agreement with test results was found. (author). 198 refs., 126 figs., 21 tabs.

  16. The investigation of structure, chemical composition, hydrogen isotope trapping and release processes in deposition layers on surfaces exposed to DIII-D divertor plasma

    International Nuclear Information System (INIS)

    Buzhinskij, O.I.; Opimach, I.V.; Barsuk, V.A.; Arkhipov, I.I.; Whyte, D.; Wampler, W.R.

    1998-05-01

    The exposure of ATG graphite sample to DIII-D divertor plasma was provided by the DiMES (Divertor Material Evaluation System) mechanism. The graphite sample arranged to receive the parallel heat flux on a small region of the surface was exposed to 600ms of outer strike point plasma. The sample was constructed to collect the eroded material directed downward into a trapping zone onto s Si disk collector. The average heat flux onto the graphite sample during the exposure was about 200W/cm 2 , and the parallel heat flux was about 10 KW/cm 2 . After the exposure the graphite sample and Si collector disk were analyzed using SEM, NRA, RBS, Auger spectroscopy. IR and Raman spectroscopy. The thermal desorption was studied also. The deposited coating on graphite sample is amorphous carbon layer. Just upstream of the high heat flux zone the redeposition layer has a globular structure. The deposition layer on Si disk is composed also from carbon but has a diamond-like structure. The areal density of C and D in the deposited layer on Si disk varied in poloidal and toroidal directions. The maximum D/C areal density ratio is about 0.23, maximum carbon density is about 3.8 x 10 18 cm -2 , maximum D area density is about 3 x 10 17 cm 2 . The thermal desorption spectrum had a peak at 1,250K

  17. Techniques for measurement of heat flux in furnace waterwalls of boilers and prediction of heat flux – A review

    International Nuclear Information System (INIS)

    Sankar, G.; Chandrasekhara Rao, A.; Seshadri, P.S.; Balasubramanian, K.R.

    2016-01-01

    Highlights: • Heat flux measurement techniques applicable to boiler water wall are elaborated. • Applications involving heat flux measurement in boiler water wall are discussed. • Appropriate technique for usage in high ash Indian coal fired boilers is required. • Usage of chordal thermocouple is suggested for large scale heat flux measurements. - Abstract: Computation of metal temperatures in a furnace waterwall of a boiler is necessary for the proper selection of tube material and thickness. An adequate knowledge of the heat flux distribution in the furnace walls is a prerequisite for the computation of metal temperatures. Hence, the measurement of heat flux in a boiler waterwall is necessary to arrive at an optimum furnace design, especially for high ash Indian coal fired boilers. Also, a thoroughly validated furnace model will result in a considerable reduction of the quantum of experimentation to be carried out. In view of the above mentioned scenario, this paper reviews the research work carried out by various researchers by experimentation and numerical simulation in the below mentioned areas: (i) furnace modeling and heat flux prediction, (ii) heat flux measurement techniques and (iii) applications of heat flux measurements.

  18. Development of integrated SOL/Divertor code and simulation study of the JT-60U/JT-60SA tokamaks

    International Nuclear Information System (INIS)

    Kawashima, H.; Shimizu, K.; Takizuka, T.

    2007-01-01

    To predict the particle and heat controllability in the divertor of tokamak reactors such as ITER and to optimize the divertor design, comprehensive simulations by integrated modelling with taking in various physical processes are indispensable. For the design study of ITER divertor, the modelling codes such as B2, UEDGE and EDGE2D have been developed, and their results have contributed to the evolution of the divertor concept. In Japan Atomic Energy Agency (JAEA), SOL/divertor codes have also been developed for the interpretation and the prediction on behaviours of plasmas, neutrals and impurities in the SOL/divertor regions. The code development is originally carried out since physics models can be verified quickly and flexibly under the circumstance of close collaboration with JT-60 team. Figure 1 shows our code system, which consists of the 2 dimensional fluid code SOLDOR, the neutral Monte Carlo (MC) code NEUT2D, and the impurity MC code IMPMC. The particle simulation code PARASOL has also been developed in order to establish the physics modelling used in fluid simulations. Integration of SOLDOR, NEUT2D and IMPMC, called the '' SONIC '' code, is being carried out to simulate self-consistently the SOL/divertor plasmas in present tokamaks and in future devices. Combination of the SOLDOR and NEUT2D was completed, which has the features such as 1) high-resolution oscillation-free scheme in solving fluid equations, 2) neutral transport calculation under the fine meshes, 3) success in reduction of MC noise, 4) optimization on the massive parallel computer, etc. The simulation reproduces the X-point MARFE in the JT-60U experiment. It is found that the chemically sputtered carbon at the dome causes the radiation peaking near the X-point. The performance of divertor pumping in JT-60U is evaluated from the particle balances. We also present the divertor designing of JT-60SA, which is the modification program of JT-60U to establish high beta steady-state operation. To

  19. Infrared thermography inspection methods applied to the target elements of W7-X Divertor

    International Nuclear Information System (INIS)

    Missirlian, M.; Durocher, A.; Schlosser, J.; Farjon, J.-L.; Vignal, N.; Traxler, H.; Schedler, B.; Boscary, J.

    2006-01-01

    As heat exhaust capability and lifetime of plasma-facing component (PFC) during in-situ operation are linked to the manufacturing quality, a set of non-destructive testing must be operated during R-and-D and manufacturing phases. Within this framework, advanced non-destructive examination (NDE) methods are one of the key issues to achieve a high level of quality and reliability of joining techniques in the production of high heat flux components but also to develop and built successfully PFCs for a next generation of fusion devices. In this frame, two NDE infrared thermographic approaches, which have been recently applied to the qualification of CFC target elements of the W7-X divertor during the first series production will be discussed in this paper. The first one, developed by CEA (SATIR facility) and used with successfully to the control of the mass-produced actively cooled PFCs on Tore Supra, is based on the transient thermography where the testing protocol consists in inducing a thermal transient within the heat sink structure by an alternative hot/cold water flow. The second one, recently developed by PLANSEE (ARGUS facility), is based on the pulsed thermography where the component is heated externally by a single powerful flash of light. Results obtained on qualification experiences performed during the first series production of W7-X divertor components representing about thirty mock-ups with artificial and manufacturing defects, demonstrated the capabilities of these two methods and raised the efficiency of inspection to a level which is appropriate for industrial application. This comparative study, associated to a cross-checking analysis between the high heat flux performance tests and these inspection methods by infrared thermography, showed a good reproducibility and allowed to set a detectable limit specific at each method. Finally, the detectability of relevant defects showed excellent coincidence with thermal images obtained from high heat flux

  20. Power load limits of the WENDELSTEIN 7-X target elements-comparison of experimental results and design values for power loads up to the critical heat flux

    International Nuclear Information System (INIS)

    Greuner, H; Boeswirth, B; Boscary, J; Leuprecht, A; Plankensteiner, A

    2007-01-01

    The power load limits of the WENDELSTEIN7-X divertor target elements were experimentally evaluated with heat loads considerably exceeding the expected operating conditions. The water-cooled elements are designed for steady-state heat flux of 10 MW m -2 and to remove a power load up to 100 kW. The elements must allow a limited operation time at 12 MW m -2 steady-state and should not fail for short pulses of up to 15 MW m -2 for cooling conditions in the subcooled nucleate boiling regime. In the framework of the qualification phase, pre-series target elements were loaded up to 24 MW m -2 without loss of CFC tiles. A critical heat flux at the target of 31 MW m -2 was achieved. The paper discusses the results of the tests performed at the high heat flux test facility GLADIS. The experimental results compared to transient nonlinear fine element method (FEM) calculations confirm a high thermal safety margin of the target design sufficient for plasma operation in W7-X

  1. Design and Test of Wendelstein 7-X Water-Cooled Divertor Scraper

    Energy Technology Data Exchange (ETDEWEB)

    Boscary, J. [Max-Planck-Institut fur Plasmaphysik, EURATOM Association, Garching, Germany; Greuner, Henri [Max Planck Institute for Plasma Physics, Garching, Germany; Ehrke, Gunnar [Max Planck Institute of Plasma Physics, Greifswald, Germany; Boeswirth, Bernd [Max Planck Institute for Plasma Physics, Garching, Germany; Wang, Zhongwei [Max Planck Institute for Plasma Physics, Garching, Germany; Clark, Emily [The University of Tennessee, Knoxville; Lumsdaine, Arnold [ORNL; Tretter, Jorg [Max Planck Institute for Plasma Physics, Garching, Germany; Junghanns, Patrick [Max Planck Institute for Plasma Physics, Garching, Germany; Stadler, Reinhold [Max Planck Institute for Plasma Physics, Garching, Germany; McGinnis, William Dean [ORNL; Lore, Jeremy D. [ORNL; Team, W7-X [Max-Planck-Institut fur Plasmaphysik, Griefswald, Germany

    2018-04-01

    Heat load calculations have indicated the possible overloading of the ends of the water-cooled divertor facing the pumping gap beyond their technological limit. The intention of the scraper is the interception of some of the plasma fluxes both upstream and downstream before they reach the divertor surface. The scraper is divided into six modules of four plasma facing components (PFCs); each module has four PFCs hydraulically connected in series by two water boxes (inlet and outlet). A full-scale prototype of one module has been manufactured. Development activities have been carried out to connect the water boxes to the cooling pipes of the PFCs by tungsten inert gas internal orbital welding. This prototype was successfully tested in the GLADIS facility with 17 MW/m2 for 500 cycles. The results of these activities have confirmed the possible technological basis for a fabrication of the water-cooled scraper.

  2. Scrape-off layer and divertor theory meeting: Proceedings

    International Nuclear Information System (INIS)

    1994-03-01

    This report contains viewgraphs on the following topics: fluid modelling of neutrals in the SOL and divertor; instabilities of gas-fueled divertors: theory and adaptive simulations; stability of ionization fronts of gaseous divertor plasmas; monte carlo calculation of heat transport; reduced charge model for edge impurity flows; thermally collapsed solutions for gaseous/radiative divertors; adaptive grid methods in transport simulation; advanced numerical solution algorithms applied to the multispecies edge plasma equations; two-dimensional edge plasma simulation using the multigrid method; neutral behavior and the effects of neutral-neutral and neutral-ion elastic scattering in the ITER gaseous divertor; particle throughput in the TPX divertor; marfes in tokamaks; a comparative study of the limiter and divertor edge plasmas in TEXT-U; issues of toroidal tokamak-type divertor simulators; ASDEX upgrade; the ITER divertor; the DIII-D divertor program and TPX divertor; DEGAS 2: a transmission/escape probabilities model for neutral particle transport: comparison with DEGAS 2; a collisional radiative model of hydrogen for high recycling divertors; comparison of fluid and non- fluid neutral models in B2.5; DIII-D radiative divertor simulations; 3-D fluid simulations of turbulence from conducting wall mode; turbulence and drifts in SOL plasmas; recent results for 1 1/2-D ITER gas target divertor modelling; evaluation of pumping and fueling in coupled core, SOL, and divertor chamber calculations; and ITER gas target divertors: comparison of volume recombination and large radial transport scenarios using DEGAS

  3. Thermal effects of runaway electrons in an armoured divertor

    International Nuclear Information System (INIS)

    Stad, R.C.L. van der.

    1993-12-01

    This report describes the results of a numerical thermal analysis of the heat deposition of runaway electrons accompanying plasma disruptions in a armoured divertor. The divertor concepts studied are carbon on molybdenum and beryllium on copper. The conclusion is that the runaway electrons can cause melting of the armour as well as melting of the structure and can damage the divertor severely. (orig.)

  4. Dynamic ELM and divertor control using resonant toroidal multi-mode magnetic fields in DIII-D and EAST

    Science.gov (United States)

    Sun, Youwen

    2017-10-01

    A rotating n = 2 Resonant Magnetic Perturbation (RMP) field combined with a stationary n = 3 RMP field has validated predictions that access to ELM suppression can be improved, while divertor heat and particle flux can also be dynamically controlled in DIII-D. Recent observations in the EAST tokamak indicate that edge magnetic topology changes, due to nonlinear plasma response to magnetic perturbations, play a critical role in accessing ELM suppression. MARS-F code MHD simulations, which include the plasma response to the RMP, indicate the nonlinear transition to ELM suppression is optimized by configuring the RMP coils to drive maximal edge stochasticity. Consequently, mixed toroidal multi-mode RMP fields, which produce more densely packed islands over a range of additional rational surfaces, improve access to ELM suppression, and further spread heat loading on the divertor. Beneficial effects of this multi-harmonic spectrum on ELM suppression have been validated in DIII-D. Here, the threshold current required for ELM suppression with a mixed n spectrum, where part of the n = 3 RMP field is replaced by an n = 2 field, is smaller than the case with pure n = 3 field. An important further benefit of this multi-mode approach is that significant changes of 3D particle flux footprint profiles on the divertor are found in the experiment during the application of a rotating n = 2 RMP field superimposed on a static n = 3 RMP field. This result was predicted by modeling studies of the edge magnetic field structure using the TOP2D code which takes into account plasma response from MARS-F code. These results expand physics understanding and potential effectiveness of the technique for reliably controlling ELMs and divertor power/particle loading distributions in future burning plasma devices such as ITER. Work supported by USDOE under DE-FC02-04ER54698 and NNSF of China under 11475224.

  5. ADX: A high Power Density, Advanced RF-Driven Divertor Test Tokamak for PMI studies

    Science.gov (United States)

    Whyte, Dennis; ADX Team

    2015-11-01

    The MIT PSFC and collaborators are proposing an advanced divertor experiment, ADX; a divertor test tokamak dedicated to address critical gaps in plasma-material interactions (PMI) science, and the world fusion research program, on the pathway to FNSF/DEMO. Basic ADX design features are motivated and discussed. In order to assess the widest range of advanced divertor concepts, a large fraction (>50%) of the toroidal field volume is purpose-built with innovative magnetic topology control and flexibility for assessing different surfaces, including liquids. ADX features high B-field (>6 Tesla) and high global power density (P/S ~ 1.5 MW/m2) in order to access the full range of parallel heat flux and divertor plasma pressures foreseen for reactors, while simultaneously assessing the effect of highly dissipative divertors on core plasma/pedestal. Various options for efficiently achieving high field are being assessed including the use of Alcator technology (cryogenic cooled copper) and high-temperature superconductors. The experimental platform would also explore advanced lower hybrid current drive and ion-cyclotron range of frequency actuators located at the high-field side; a location which is predicted to greatly reduce the PMI effects on the launcher while minimally perturbing the core plasma. The synergistic effects of high-field launchers with high total B on current and flow drive can thus be studied in reactor-relevant boundary plasmas.

  6. HRP facility for fabrication of ITER vertical target divertor full scale plasma facing units

    International Nuclear Information System (INIS)

    Visca, Eliseo; Roccella, S.; Candura, D.; Palermo, M.; Rossi, P.; Pizzuto, A.; Sanguinetti, G.P.; Mancini, A.; Verdini, L.; Cacciotti, E.; Cerri, V.; Mugnaini, G.; Reale, A.; Giacomi, G.

    2015-01-01

    Highlights: • R&D activities for the manufacturing of ITER divertor high heat flux plasma-facing components (HHFC). • ENEA and Ansaldo have jointly manufactured several actively cooled monoblock mock-ups and prototypical components. • ENEA and ANSALDO NUCLEARE jointly participate to the European program for the qualification of the manufacturing technology for the ITER divertor IVT. • Successful manufacturing by HRP (Hot Radial Pressing) of first full-scale full-W armored IVT qualification prototype. - Abstract: ENEA and Ansaldo Nucleare S.p.A. (ANN) have being deeply involved in the European development activities for the manufacturing of the ITER Divertor Inner Vertical Target (IVT) plasma-facing components. During normal operation the heat flux deposited on the bottom segment of divertor is 5–10 MW/m 2 but the capability to remove up to 20 MW/m 2 during transient events of 10 s must also be demonstrated. In order to fulfill ITER requirements, ENEA has set up and widely tested a manufacturing process, named Hot Radial Pressing (HRP). The last challenge is now to fabricate full-scale prototypes of the IVT, aimed to be qualified for the next step, i.e. the series production. On the basis of the experience of manufacturing hundreds of small mock-ups, ENEA designed and installed a new suitable HRP facility. The objective of getting a final shaped plasma facing unit (PFU) that satisfies these requirements is an ambitious target because tolerances set by ITER/F4E are very tight. The setting-up of the equipment started with the fabrication of full scale and representative ‘dummies’ in which stainless steel instead of CFC or W was used for monoblocks. The results confirmed that dimensions were compliant with the required tolerances. The paper reports a brief description of the innovative HRP equipment and the dimensional check results after HRP of the first full-scale full-W PFU.

  7. HRP facility for fabrication of ITER vertical target divertor full scale plasma facing units

    Energy Technology Data Exchange (ETDEWEB)

    Visca, Eliseo, E-mail: eliseo.visca@enea.it [Unità Tecnica Fusione, ENEA C. R. Frascati, via E. Fermi 45, IT-00044 Frascati (Roma) (Italy); Roccella, S. [Unità Tecnica Fusione, ENEA C. R. Frascati, via E. Fermi 45, IT-00044 Frascati (Roma) (Italy); Candura, D.; Palermo, M. [Ansaldo Nucleare S.p.A., Corso Perrone 25, IT-16152 Genova (Italy); Rossi, P.; Pizzuto, A. [Unità Tecnica Fusione, ENEA C. R. Frascati, via E. Fermi 45, IT-00044 Frascati (Roma) (Italy); Sanguinetti, G.P. [Ansaldo Nucleare S.p.A., Corso Perrone 25, IT-16152 Genova (Italy); Mancini, A.; Verdini, L.; Cacciotti, E.; Cerri, V.; Mugnaini, G.; Reale, A.; Giacomi, G. [Unità Tecnica Fusione, ENEA C. R. Frascati, via E. Fermi 45, IT-00044 Frascati (Roma) (Italy)

    2015-10-15

    Highlights: • R&D activities for the manufacturing of ITER divertor high heat flux plasma-facing components (HHFC). • ENEA and Ansaldo have jointly manufactured several actively cooled monoblock mock-ups and prototypical components. • ENEA and ANSALDO NUCLEARE jointly participate to the European program for the qualification of the manufacturing technology for the ITER divertor IVT. • Successful manufacturing by HRP (Hot Radial Pressing) of first full-scale full-W armored IVT qualification prototype. - Abstract: ENEA and Ansaldo Nucleare S.p.A. (ANN) have being deeply involved in the European development activities for the manufacturing of the ITER Divertor Inner Vertical Target (IVT) plasma-facing components. During normal operation the heat flux deposited on the bottom segment of divertor is 5–10 MW/m{sup 2} but the capability to remove up to 20 MW/m{sup 2} during transient events of 10 s must also be demonstrated. In order to fulfill ITER requirements, ENEA has set up and widely tested a manufacturing process, named Hot Radial Pressing (HRP). The last challenge is now to fabricate full-scale prototypes of the IVT, aimed to be qualified for the next step, i.e. the series production. On the basis of the experience of manufacturing hundreds of small mock-ups, ENEA designed and installed a new suitable HRP facility. The objective of getting a final shaped plasma facing unit (PFU) that satisfies these requirements is an ambitious target because tolerances set by ITER/F4E are very tight. The setting-up of the equipment started with the fabrication of full scale and representative ‘dummies’ in which stainless steel instead of CFC or W was used for monoblocks. The results confirmed that dimensions were compliant with the required tolerances. The paper reports a brief description of the innovative HRP equipment and the dimensional check results after HRP of the first full-scale full-W PFU.

  8. Study of particle pumping characteristics for different pumping geometries in JT-60U and DIII-D divertors

    International Nuclear Information System (INIS)

    Takenaga, H.; Sakasai, A.; Kubo, H.

    2001-01-01

    Particle pumping characteristics were compared between pumping from the inner side private flux region (IPP) and pumping from both sides of the private flux region (BPP) in the JT-60U W shaped divertor, and between JT-60U IPP and pumping in the DIII-D lower baffled divertor. The pumping flux for BPP is smaller than that for IPP by about a factor of 2 with weak in-out asymmetry of recycling neutral flux and by a factor of 3.5-6.5 with strong in-out asymmetry. The reduction of the pumping flux for BPP is consistent with Monte Carlo simulations, where backflow at the outer pumping slot is observed due to in-out recycling asymmetry. The pumping flux in DIII-D at I p =0.8 MA and B T =1.6 T is comparable to or smaller than that for JT-60U IPP at I p =1.0 MA, B T =3.8 T and I p =1.5 MA, B T =3.5 T in the same density regime. In the DIII-D divertor with pumping from the private flux region, the pumping flux decreases with increasing in-out asymmetry. The pumping flux normalized by the integrated D α emission over the whole plasma exhibits a similar dependence on the distance between the pumping slot and the strike point in JT-60U IPP and the DIII-D lower divertor with pumping through the outer divertor plasma region. (author)

  9. ITER divertor, design issues and research and development

    International Nuclear Information System (INIS)

    Tivey, R.; Ando, T.; Antipenkov, A.; Barabash, V.; Chiocchio, S.; Federici, G.; Ibbott, C.; Jakeman, R.; Janeschitz, G.; Raffray, R.; Mazul, I.; Pacher, H.; Ulrickson, M.; Vieider, G.

    1999-01-01

    Over the period of the ITER Engineering Design Activity (EDA) the results from physics experiments, modelling, engineering analyses and R and D, have been brought together to provide a design for an ITER divertor. The design satisfies all necessary requirements for steady state and transient heat flux, nuclear shielding, pumping, tritium inventory, impurity control, armour lifetime, electromagnetic loads, diagnostics, and remote maintenance. The design consists of 60 cassettes each comprising a cassette body onto which the plasma facing components (PFCs) are mounted. Each cassette is supported by toroidal rails which are attached to the vacuum vessel. For the PFCs the final armour choice is carbon-fibre-composite (CfC) for the strike point regions and tungsten in all remaining areas. R and D has demonstrated that CfC monoblocks can routinely withstand heat loads up to 20 MW m -2 10 MW m -2 . Analysis and experiment show that a CfC armour thickness of ∝20 mm will provide sufficient lifetime for at least 1000 full power pulses. The thickness of the cassette body is sufficient to shield the vacuum vessel, so that, if necessary, rewelding is possible, and also provides sufficient stiffness against electromagnetically generated loads. The cassette design provides efficient and proven remote maintenance which should allow exchange of a complete divertor within ∝6 months. (orig.)

  10. ITER divertor, design issues and research and development

    Energy Technology Data Exchange (ETDEWEB)

    Tivey, R.; Ando, T.; Antipenkov, A.; Barabash, V.; Chiocchio, S.; Federici, G.; Ibbott, C.; Jakeman, R.; Janeschitz, G.; Raffray, R. [ITER Joint Central Team, Garching (Germany). Joint Central Work Site; Akiba, M. [Japan Atomic Energy Research Institute, Naka-machi, Ibaraki-ken (Japan); Mazul, I. [Efremov Institute, St Petersburg (Russian Federation); Pacher, H. [NET Team, Boltzmannstr. 2, D-85748, Garching (Germany); Ulrickson, M. [Sandia National Laboratories, Albuquerque, NM (United States); Vieider, G. [NET Team, Boltzmannstr. 2, D-85748, Garching (Germany)

    1999-11-01

    Over the period of the ITER Engineering Design Activity (EDA) the results from physics experiments, modelling, engineering analyses and R and D, have been brought together to provide a design for an ITER divertor. The design satisfies all necessary requirements for steady state and transient heat flux, nuclear shielding, pumping, tritium inventory, impurity control, armour lifetime, electromagnetic loads, diagnostics, and remote maintenance. The design consists of 60 cassettes each comprising a cassette body onto which the plasma facing components (PFCs) are mounted. Each cassette is supported by toroidal rails which are attached to the vacuum vessel. For the PFCs the final armour choice is carbon-fibre-composite (CfC) for the strike point regions and tungsten in all remaining areas. R and D has demonstrated that CfC monoblocks can routinely withstand heat loads up to 20 MW m{sup -2}10 MW m{sup -2}. Analysis and experiment show that a CfC armour thickness of {proportional_to}20 mm will provide sufficient lifetime for at least 1000 full power pulses. The thickness of the cassette body is sufficient to shield the vacuum vessel, so that, if necessary, rewelding is possible, and also provides sufficient stiffness against electromagnetically generated loads. The cassette design provides efficient and proven remote maintenance which should allow exchange of a complete divertor within {proportional_to}6 months. (orig.)

  11. Experimental study of divertor plasma-facing components damage under a combination of pulsed and quasi-stationary heat loads relevant to expected transient events at ITER

    International Nuclear Information System (INIS)

    Klimov, N S; Podkovyrov, V L; Kovalenko, D V; Zhitlukhin, A M; Barsuk, V A; Mazul, I V; Giniyatulin, R N; Kuznetsov, V Ye; Riccardi, B; Loarte, A; Merola, M; Koidan, V S; Linke, J; Landman, I S; Pestchanyi, S E; Bazylev, B N

    2011-01-01

    This paper concerns the experimental study of damage of ITER divertor plasma-facing components (PFCs) under a combination of pulsed plasma heat loads (representative of controlled ITER type I edge-localized modes (ELMs)) and quasi-stationary heat loads (representative of the high heat flux (HHF) thermal fatigue expected during ITER normal operations and slow transient events). The PFC's tungsten armor damage under pulsed plasma exposure was driven by (i) the melt layer motion, which leads to bridges formation between neighboring tiles and (ii) the W brittle failure giving rise to a stable crack pattern on the exposed surface. The crack width reaches a saturation value that does not exceed some tens of micrometers after several hundreds of ELM-like pulses. HHF thermal fatigue tests have shown (i) a peeling-off of the re-solidified material due to its brittle failure and (ii) a significant widening (up to 10 times) of the cracks and the formation of additional cracks.

  12. Experimental activity on the definition of acceptance criteria for the ITER divertor plasma facing components

    International Nuclear Information System (INIS)

    Escourbiac, F.; Constans, S.; Vignal, N.; Cantone, V.; Richou, M.; Durocher, A.; Riccardi, B.; Bobin, I.; Jouvelot, J.L.; Merola, M.

    2009-01-01

    Tens of thousands of armor/heat sink joints will be produced by the industry during the manufacturing of ITER divertor PFC, statistically, there is a probability that joints with defects be delivered. The purpose of this paper is to study the detection and evolution during operation of calibrated defects artificially implemented on samples, as an experimental basis for the definition of acceptance criteria for the bond armor/heat sink in the frame of industrial manufacturing conditions.It was found that current CFC monoblock design option was compatible with the heat loads specified at the lower part of the vertical target (up to 20 MW/m 2 ), including the presence of armor/heat sink defects (up to 50 deg. extension for a location at 0 deg. or 45 deg.) detectable with NDE techniques developed in Europe (US, SATIR). The current W monoblock design appeared suitable for the upper part of the vertical target with defects extension up to 50 deg. but is not adapted for heat flux of 20 MW/m 2 . The studied W flat tile design proved to be compatible with fluxes of 5 MW/m 2 but unable to sustain cycling fluxes of 10 MW/m 2 .

  13. Physics conclusions in support of ITER W divertor monoblock shaping

    Directory of Open Access Journals (Sweden)

    R.A. Pitts

    2017-08-01

    Full Text Available The key remaining physics design issue for the ITER tungsten (W divertor is the question of monoblock (MB front surface shaping in the high heat flux target areas of the actively cooled targets. Engineering tolerance specifications impose a challenging maximum radial step between toroidally adjacent MBs of 0.3mm. Assuming optical projection of the parallel heat loads, magnetic shadowing of these edges is required if quasi-steady state melting is to be avoided under certain conditions during burning plasma operation and transiently during edge localized mode (ELM or disruption induced power loading. An experiment on JET in 2013 designed to investigate the consequences of transient W edge melting on ITER, found significant deficits in the edge power loads expected on the basis of simple geometric arguments, throwing doubt on the understanding of edge loading at glancing field line angles. As a result, a coordinated multi-experiment and simulation effort was initiated via the International Tokamak Physics Activity (ITPA and through ITER contracts, aimed at improving the physics basis supporting a MB shaping decision from the point of view both of edge power loading and melt dynamics. This paper reports on the outcome of this activity, concluding first that the geometrical approximation for leading edge power loading on radially misaligned poloidal leading edges is indeed valid. On this basis, the behaviour of shaped and unshaped monoblock surfaces under stationary and transient loads, with and without melting, is compared in order to examine the consequences of melting, or power overload in context of the benefit, or not, of shaping. The paper concludes that MB top surface shaping is recommended to shadow poloidal gap edges in the high heat flux areas of the ITER divertor targets.

  14. ADX: a high field, high power density, advanced divertor and RF tokamak

    Science.gov (United States)

    LaBombard, B.; Marmar, E.; Irby, J.; Terry, J. L.; Vieira, R.; Wallace, G.; Whyte, D. G.; Wolfe, S.; Wukitch, S.; Baek, S.; Beck, W.; Bonoli, P.; Brunner, D.; Doody, J.; Ellis, R.; Ernst, D.; Fiore, C.; Freidberg, J. P.; Golfinopoulos, T.; Granetz, R.; Greenwald, M.; Hartwig, Z. S.; Hubbard, A.; Hughes, J. W.; Hutchinson, I. H.; Kessel, C.; Kotschenreuther, M.; Leccacorvi, R.; Lin, Y.; Lipschultz, B.; Mahajan, S.; Minervini, J.; Mumgaard, R.; Nygren, R.; Parker, R.; Poli, F.; Porkolab, M.; Reinke, M. L.; Rice, J.; Rognlien, T.; Rowan, W.; Shiraiwa, S.; Terry, D.; Theiler, C.; Titus, P.; Umansky, M.; Valanju, P.; Walk, J.; White, A.; Wilson, J. R.; Wright, G.; Zweben, S. J.

    2015-05-01

    The MIT Plasma Science and Fusion Center and collaborators are proposing a high-performance Advanced Divertor and RF tokamak eXperiment (ADX)—a tokamak specifically designed to address critical gaps in the world fusion research programme on the pathway to next-step devices: fusion nuclear science facility (FNSF), fusion pilot plant (FPP) and/or demonstration power plant (DEMO). This high-field (⩾6.5 T, 1.5 MA), high power density facility (P/S ˜ 1.5 MW m-2) will test innovative divertor ideas, including an ‘X-point target divertor’ concept, at the required performance parameters—reactor-level boundary plasma pressures, magnetic field strengths and parallel heat flux densities entering into the divertor region—while simultaneously producing high-performance core plasma conditions that are prototypical of a reactor: equilibrated and strongly coupled electrons and ions, regimes with low or no torque, and no fuelling from external heating and current drive systems. Equally important, the experimental platform will test innovative concepts for lower hybrid current drive and ion cyclotron range of frequency actuators with the unprecedented ability to deploy launch structures both on the low-magnetic-field side and the high-magnetic-field side—the latter being a location where energetic plasma-material interactions can be controlled and favourable RF wave physics leads to efficient current drive, current profile control, heating and flow drive. This triple combination—advanced divertors, advanced RF actuators, reactor-prototypical core plasma conditions—will enable ADX to explore enhanced core confinement physics, such as made possible by reversed central shear, using only the types of external drive systems that are considered viable for a fusion power plant. Such an integrated demonstration of high-performance core-divertor operation with steady-state sustainment would pave the way towards an attractive pilot plant, as envisioned in the ARC concept

  15. Analysis of heat transfer under high heat flux nucleate boiling conditions

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y.; Dinh, N. [3145 Burlington Laboratories, Raleigh, NC (United States)

    2016-07-15

    Analysis was performed for a heater infrared thermometric imaging temperature data obtained from high heat flux pool boiling and liquid film boiling experiments BETA. With the OpenFOAM solver, heat flux distribution towards the coolant was obtained by solving transient heat conduction of heater substrate given the heater surface temperature data as boundary condition. The so-obtained heat flux data was used to validate them against the state-of-art wall boiling model developed by D. R. Shaver (2015) with the assumption of micro-layer hydrodynamics. Good agreement was found between the model prediction and data for conditions away from the critical heat flux (CHF). However, the data indicate a different heat transfer pattern under CHF, which is not captured by the current model. Experimental data strengthen the notion of burnout caused by the irreversible hot spot due to failure of rewetting. The observation forms a basis for a detailed modeling of micro-layer hydrodynamics under high heat flux.

  16. Analysis of heat transfer under high heat flux nucleate boiling conditions

    International Nuclear Information System (INIS)

    Liu, Y.; Dinh, N.

    2016-01-01

    Analysis was performed for a heater infrared thermometric imaging temperature data obtained from high heat flux pool boiling and liquid film boiling experiments BETA. With the OpenFOAM solver, heat flux distribution towards the coolant was obtained by solving transient heat conduction of heater substrate given the heater surface temperature data as boundary condition. The so-obtained heat flux data was used to validate them against the state-of-art wall boiling model developed by D. R. Shaver (2015) with the assumption of micro-layer hydrodynamics. Good agreement was found between the model prediction and data for conditions away from the critical heat flux (CHF). However, the data indicate a different heat transfer pattern under CHF, which is not captured by the current model. Experimental data strengthen the notion of burnout caused by the irreversible hot spot due to failure of rewetting. The observation forms a basis for a detailed modeling of micro-layer hydrodynamics under high heat flux.

  17. Two-dimensional analysis for a scrapeoff and divertor regions with an MHD model

    International Nuclear Information System (INIS)

    Ueda, Noriaki; Kasai, Masao; Hitoki, Shigehisa

    1987-08-01

    With a two-dimensional time dependent fluid code for transport processes in the edge plasma in a tokamak, coupled with Monte-Carlo method for neutral gas behavior, preliminary numerical study has been carried out for the FER divertor. Design base data such as energy flux, particle flux and so on which are essentially important to make an divertor design reliable have been obtained. (author)

  18. High heat flux tests of the WENDELSTEIN 7-X pre-series target elements

    International Nuclear Information System (INIS)

    Greuner, H.; Boeswirth, B.; Boscary, J.; Plankensteiner, A.; Schedler, B.

    2007-01-01

    The high heat flux (HHF) testing of WENDELSTEIN 7-X pre-series target elements is an indispensable step in the qualification of the manufacturing process. A set of 20 full scale pre-series elements was manufactured by PLANSEE SE to validate the materials and manufacturing technologies prior to the start of the series production. The HHF tests were performed in the ion beam test facility GLADIS. All actively water-cooled elements were tested for about 100 cycles at 10 MW/m 2 (10-15 s pulse duration). Several elements were loaded with even higher cycle numbers (up to 1000) and heat loads up to 24 MW/m 2 . Hot spots were, observed at the edges of several tiles during the HHF tests indicating local bonding problems of the CFC. The thermo-mechanical behaviour under HHF loading has been evaluated and compared to the FEM predictions. The measured temperatures and strains confirm the chosen FEM approach. This allows a component optimisation to achieve a successful series production of the W7-X divertor target elements

  19. Westinghouse compact poloidal divertor reference design

    International Nuclear Information System (INIS)

    Yang, T.F.; Lee, A.Y.; Ruck, G.W.

    1977-08-01

    A feasible compact poloidal divertor system has been designed as an impurity control and vacuum vessel first-wall protection option for the TNS tokamak. The divertor coils are inside the TF coil array and vacuum vessel. The poloidal divertor is formed by a pair of coil sets with zero net current. Each set consists of a number of coils forming a dish-shaped washer-like ring. The magnetic flux in the space between the coil sets is compressed vertically to limit the height and to expand the horizontal width of the particle and energy burial chamber which is located in the gap between the coil sets. The intensity of the poloidal field is increased to make the pitch angle of the flux lines very large so that the diverted particles can be intercepted by a large number of panels oriented at a small angle with respect to the flux lines. They are carefully shaped and designed such that the entire surfaces are exposed to the incident particles and are not shadowed by each other. Large collecting surface areas can be obtained. Flowing liquid lithium film and solid metal panels have been considered as the particle collectors. The power density for the former is designed at 1 MW/m 2 and for the latter 0.5 MW/m 2 . The major mechanical, thermal, and vacuum problems have been evaluated in sufficient detail so that the advantages and difficulties are identified. A complete functional picture is presented

  20. An analytical erosion model for divertor plates and limiter experiments in CHS

    International Nuclear Information System (INIS)

    Sagara, A.; Noda, N.; Akiyama, R.; Arimoto, H.; Idei, H.; Iguchi, H.; Kaneko, O.; Kohmoto, T.; Kubo, S.; Matsuoka, K.; Morita, S.; Motojima, O.; Nishimura, K.; Okamura, S.; Takahasi, C.; Takita, Y.; Yamada, I.; Matsunami, N.; Rice, J.; Yamada, H.; Shoji, T.; Ueda, M.

    1992-01-01

    A self-consistent analytical solution for net erosion of a divertor plate which is set perpendicular to magnetic field lines is presented. The primary flux profile of hydrogen and impurities except redepositing particles is externally given as well as the return ratio of sputtered atoms to the plate. In the direction along the divertor trace, all conditions are uniform. The ionization mean free path is assumed constant to simplify equations. The analytical solution is compared with net erosion experiments carried out in compact helical system (CHS) by exposing a graphite target to a neutral beam heated plasma column introduced perpendicularly to the target along the magnetic field lines through a 2 cm slit opend on a graphite limiter. After exposure to 98 discharges, the target surface is analyzed with Rutherford backscattering method. Deposition profiles of Ti and O impurities are very well explained with the analytical predictions. (orig.)

  1. Pyrolytic graphite gauge for measuring heat flux

    Science.gov (United States)

    Bunker, Robert C. (Inventor); Ewing, Mark E. (Inventor); Shipley, John L. (Inventor)

    2002-01-01

    A gauge for measuring heat flux, especially heat flux encountered in a high temperature environment, is provided. The gauge includes at least one thermocouple and an anisotropic pyrolytic graphite body that covers at least part of, and optionally encases the thermocouple. Heat flux is incident on the anisotropic pyrolytic graphite body by arranging the gauge so that the gauge surface on which convective and radiative fluxes are incident is perpendicular to the basal planes of the pyrolytic graphite. The conductivity of the pyrolytic graphite permits energy, transferred into the pyrolytic graphite body in the form of heat flux on the incident (or facing) surface, to be quickly distributed through the entire pyrolytic graphite body, resulting in small substantially instantaneous temperature gradients. Temperature changes to the body can thereby be measured by the thermocouple, and reduced to quantify the heat flux incident to the body.

  2. Heat transfer and critical heat flux in a spiral flow in an asymmetrical heated tube; Transfert thermique et flux critique dans un ecoulement helicoidal en tube chauffe asymetriquement

    Energy Technology Data Exchange (ETDEWEB)

    Boscary, J [CEA Centre d` Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Direction des Sciences de la Matiere; [Association Euratom-CEA, Centre d` Etudes Nucleaires de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee

    1997-03-01

    The design of plasma facing components is crucial for plasma performance in next fusion reactors. These elements will be submitted to very high heat flux. They will be actively water-cooled by swirl tubes in the subcooled boiling regime. High heat flux experiments were conducted in order to analyse the heat transfer and to evaluate the critical heat flux. Water-cooled mock-ups were one-side heated by an electron beam gun for different thermal-hydraulic conditions. The critical heat flux was detected by an original method based on the isotherm modification on the heated surface. The wall heat transfer law including forced convection and subcooled boiling regimes was established. Numerical calculations of the material heat transfer conduction allowed the non-homogeneous distribution of the wall temperature and of the wall heat flux to be evaluated. The critical heat flux value was defined as the wall maximum heat flux. A critical heat flux model based on the liquid sublayer dryout under a vapor blanket was established. A good agreement with test results was found. (author) 197 refs.

  3. Numerical study of the connection lengths for various magnetic configurations in Wendelstein 7-X to optimize the heat load on the divertor

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, Priyanjana; Hoelbe, Hauke; Sunn Pedersen, Thomas [Max Planck Institute of Plasma Physics, Greifswald (Germany)

    2016-07-01

    Fusion has the potential to play an important role as a future energy resource. It has the capacity to produce large-scale clean energy. The two main confinement concepts are the tokamak and the stellarator. The W7-X machine is based on stellarator principle and is using special form of coils to achieve steady-state plasma confinement. Divertors are used in tokamaks and stellarator to control the exhaust of waste gases and impurities from the machine. The divertor concept of W7-X is a so-called island divertor. The island chain isolates the confinement core from regions where the plasma-wall interaction takes place. The area of the divertor that receives the main part of the heat loads, the so-called wetted area, increases with the distance along the magnetic field from the outboard midplane to the divertor target. The connection length is relatively short in tokamaks with conventional divertors. In the stellarator island divertor, the connection length can be varied significantly, which should allow for optimization of the wetted area. We present here a numerical study of the achievable connection lengths in various W7-X configurations and discuss the possibilities for running dedicated experiments to understand the physics of what sets the wetted area.

  4. Heat flux microsensor measurements and calibrations

    Science.gov (United States)

    Terrell, James P.; Hager, Jon M.; Onishi, Shinzo; Diller, Thomas E.

    1992-01-01

    A new thin-film heat flux gage has been fabricated specifically for severe high temperature operation using platinum and platinum-10 percent rhodium for the thermocouple elements. Radiation calibrations of this gage were performed at the AEDC facility over the available heat flux range (approx. 1.0 - 1,000 W/cu cm). The gage output was linear with heat flux with a slight increase in sensitivity with increasing surface temperature. Survivability of gages was demonstrated in quench tests from 500 C into liquid nitrogen. Successful operation of gages to surface temperatures of 750 C has been achieved. No additional cooling of the gages is required because the gages are always at the same temperature as the substrate material. A video of oxyacetylene flame tests with real-time heat flux and temperature output is available.

  5. The isotope effect on divertor conditions and neutral pumping in horizontal divertor configurations in JET-ILW Ohmic plasmas

    Directory of Open Access Journals (Sweden)

    J. Uljanovs

    2017-08-01

    Full Text Available Understanding the impact of isotope mass and divertor configuration on the divertor conditions and neutral pressures is critical for predicting the performance of the ITER divertor in DT operation. To address this need, ohmically heated hydrogen and deuterium plasma experiments were conducted in JET with the ITER-like wall in varying divertor configurations. In this study, these plasmas are simulated with EDGE2D-EIRENE outfitted with a sub-divertor model, to predict the neutral pressures in the plenum with similar fashion to the experiments. EDGE2D-EIRENE predictions show that the increased isotope mass results in up to a 25% increase in peak electron densities and 15% increase in peak ion saturation current at the outer target in deuterium when compared to hydrogen for all horizontal divertor configurations. Indicating that a change from hydrogen to deuterium as main fuel decreases the neutral mean free path, leading to higher neutral density in the divertor. Consequently, this mechanism also leads to higher neutral pressures in the sub-divertor. The experimental data provided by the hydrogen and deuterium ohmic discharges shows that closer proximity of the outer strike point to the pumping plenum results in a higher neutral pressure in the sub-divertor. The diaphragm capacitance gauge pressure measurements show that a two to three-fold increase in sub-divertor pressure was achieved in the corner and nearby horizontal configurations compared to the far-horizontal configurations, likely due to ballistic transport (with respect to the plasma facing components of the neutrals into the sub-divertor. The corner divertor configuration also indicates that a neutral expansion occurs during detachment, resulting in a sub-divertor neutral density plateau as a function of upstream density at the outer-mid plane.

  6. Characteristics of the Secondary Divertor on DIII-D

    Science.gov (United States)

    Watkins, J. G.; Lasnier, C. J.; Leonard, A. W.; Evans, T. E.; Pitts, R.; Stangeby, P. C.; Boedo, J. A.; Moyer, R. A.; Rudakov, D. L.

    2009-11-01

    In order to address a concern that the ITER secondary divertor strike plates may be insufficiently robust to handle the incident pulses of particles and energy from ELMs, we performed dedicated studies of the secondary divertor plasma and scrape-off layer (SOL). Detailed measurements of the ELM energy and particle deposition footprint on the secondary divertor target plates were made with a fast IR camera and Langmuir probes and SOL profile and transport measurements were made with reciprocating probes. The secondary divertor and SOL conditions depended on changes in the magnetic balance and the core plasma density. Larger density resulted in smaller ELMs and the magnetic balance affected how many ELM particles coupled to the secondary SOL and divertor. Particularly striking are the images from a new fast IR camera that resolve ELM heat pulses and show spiral patterns with multiple peaks during ELMs in the secondary divertor.

  7. Engineering conceptual design of CFETR divertor

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Xuebing, E-mail: pengxb@ipp.cas.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Shushanhu Road 350, 230031 Hefei Anhui (China); Ye, Minyou [School of Nuclear Science and Technology, University of Science and Technology of China, Jinzhai Road 96, 230026 Hefei Anhui (China); Institute of Plasma Physics, Chinese Academy of Sciences, Shushanhu Road 350, 230031 Hefei Anhui (China); Song, Yuntao [Institute of Plasma Physics, Chinese Academy of Sciences, Shushanhu Road 350, 230031 Hefei Anhui (China); School of Nuclear Science and Technology, University of Science and Technology of China, Jinzhai Road 96, 230026 Hefei Anhui (China); Mao, Xin [Institute of Plasma Physics, Chinese Academy of Sciences, Shushanhu Road 350, 230031 Hefei Anhui (China); Chen, Peiming; Qian, Xinyuan [School of Nuclear Science and Technology, University of Science and Technology of China, Jinzhai Road 96, 230026 Hefei Anhui (China)

    2015-10-15

    Highlights: • Three divertor structures for two plasma configurations, ITER-like and snowflake. • Property of enlarging wet area for all three divertors is analyzed. • The divertor accommodating with both the plasma configurations is unfeasible. • Divertor cooling system is developed. - Abstract: The China Fusion Engineering Test Reactor (CFETR), which is in conceptual design phase, aims at producing fusion power of 50–200 MW with tritium breeding ratio of ∼1.2 and duty cycle time of 0.3–0.5. Its designed main parameters are major/minor radii of 5.7 m/1.6 m and plasma current of 10 MA. Although the fusion power is lower than the one of ITER, the relative smaller machine dimensions and planed much higher auxiliary heating power of 100–140 MW make that the power exhausting for the CFETR divertor is a very critical issue. To solve this issue, the divertor should be better designed with advanced physical operation mode, advanced configuration/geometry or high efficient cooling structure. In the paper, much effort was put on the divertor configuration and geometry. With designed magnet system, three divertor configurations can be realized, ITER-like, snowflake and super-X. However, considering structural design feasibility and remote handling compatibility, only the first two configurations were selected for the first step of engineering design. Three divertors were designed. They have different first wall geometries to accommodate with different plasma configurations, one for the ITER-like, one for the snowflake and the third one for both the configurations. All three divertors employ the same cassette body as the support and the cooling water manifold for the first wall. This feature simplifies the interface of the divertor to other components in the vacuum vessel. Besides, the cooling structure and the remote maintenance concept are also introduced in the paper.

  8. Evaluation of empirical heat transfer models using TFG heat flux sensors

    International Nuclear Information System (INIS)

    De Cuyper, T.; Broekaert, S.; Chana, K.; De Paepe, M.; Verhelst, S.

    2017-01-01

    Thermodynamic engine cycle models are used to support the development of the internal combustion engine (ICE) in a cost and time effective manner. The sub model which describes the in-cylinder heat transfer from the working gases to the combustion chamber walls plays an important role in the accuracy of these simulation tools. The heat transfer affects the power output, engine efficiency and emissions of the engine. The most common heat transfer models in engine research are the models of Annand and Woschni. These models provide an instantaneous spatial averaged heat flux. In this research, prototype thin film gauge (TFG) heat flux sensors are used to capture the transient in-cylinder heat flux behavior within a production spark ignition (SI) engine as they are small, robust and able to capture the highly transient temperature swings. An inlet valve and two different zones of the cylinder head are instrumented with multiple TFG sensors. The heat flux traces are used to calculate the convection coefficient which includes all information of the convective heat transfer phenomena inside the combustion chamber. The implementation of TFG sensors inside the combustion chamber and the signal processing technique are discussed. The heat transfer measurements are used to analyze the spatial variation in heat flux under motored and fired operation. Spatial variation in peak heat flux was observed even under motored operation. Under fired operation the observed spatial variation is mainly driven by the flame propagation. Next, the paper evaluates the models of Annand and Woschni. These models fail to predict the total heat loss even with calibration of the models coefficients using a reference motored operating condition. The effect of engine speed and inlet pressure is analyzed under motored operation after calibration of the models. The models are able to predict the trend in peak heat flux value for a varying engine speed and inlet pressure. Next, the accuracy of the

  9. Results of high heat flux tests and structural analysis of the new solid tungsten divertor tile for ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Jaksic, Nikola, E-mail: nikola.jaksic@ipp.mpg.de; Greuner, Henri; Herrmann, Albrecht; Böswirth, Bernd; Vorbrugg, Stefan

    2015-10-15

    Highlights: • The main motivation for the HHF investigation of tungsten tiles was an untypical deformation of some specimens under thermal loading, observed during the previous tests in GLADIS test facility. • A nonlinear finite element (FE) model for simulations of the GLADIS tests has been built. • The unexpected plastic deformations are mainly caused by internal stresses due to the manufacturing process. The small discrepancies among the FEA investigated and measured plastic deformations are most likely caused, beside of the practical difficulties by measuring of low items, also by tile internal stresses. • The influences of the residual stresses caused by special production processes have to be taken into account by design of the structural part made of solid tungsten. - Abstract: Tungsten as plasma-facing material for fusion devices is currently the most favorable candidate. In general solid tungsten is used for shielding the plasma chamber interior against the high heat generated from the plasma. For the purposes of implementation at ASDEX Upgrade and as a contribution to ITER the thermal performance of tungsten tiles has been extensively tested in the high heat flux test facility GLADIS during the development phase and beyond. These tests have been performed on full scale tungsten tile prototypes including their clamping and cooling structure. Simulating the adiabatically thermal loading due to plasma operation in ASDEX Upgrade, the tungsten tiles have been subjected to a thermal load with central heat flux of 10–24 MW/m{sup 2} and absorbed energy between 370 and 680 kJ. This loading results in maximum surface temperatures between 1300 °C and 2800 °C. The tests in GLADIS have been accompanied by intensive numerical investigations using FEA methods. For this purpose a multiple nonlinear finite element model has been set up. This paper discusses the main results of the high heat flux final tests and their numerical simulation. Moreover, first

  10. Results of high heat flux tests and structural analysis of the new solid tungsten divertor tile for ASDEX Upgrade

    International Nuclear Information System (INIS)

    Jaksic, Nikola; Greuner, Henri; Herrmann, Albrecht; Böswirth, Bernd; Vorbrugg, Stefan

    2015-01-01

    Highlights: • The main motivation for the HHF investigation of tungsten tiles was an untypical deformation of some specimens under thermal loading, observed during the previous tests in GLADIS test facility. • A nonlinear finite element (FE) model for simulations of the GLADIS tests has been built. • The unexpected plastic deformations are mainly caused by internal stresses due to the manufacturing process. The small discrepancies among the FEA investigated and measured plastic deformations are most likely caused, beside of the practical difficulties by measuring of low items, also by tile internal stresses. • The influences of the residual stresses caused by special production processes have to be taken into account by design of the structural part made of solid tungsten. - Abstract: Tungsten as plasma-facing material for fusion devices is currently the most favorable candidate. In general solid tungsten is used for shielding the plasma chamber interior against the high heat generated from the plasma. For the purposes of implementation at ASDEX Upgrade and as a contribution to ITER the thermal performance of tungsten tiles has been extensively tested in the high heat flux test facility GLADIS during the development phase and beyond. These tests have been performed on full scale tungsten tile prototypes including their clamping and cooling structure. Simulating the adiabatically thermal loading due to plasma operation in ASDEX Upgrade, the tungsten tiles have been subjected to a thermal load with central heat flux of 10–24 MW/m"2 and absorbed energy between 370 and 680 kJ. This loading results in maximum surface temperatures between 1300 °C and 2800 °C. The tests in GLADIS have been accompanied by intensive numerical investigations using FEA methods. For this purpose a multiple nonlinear finite element model has been set up. This paper discusses the main results of the high heat flux final tests and their numerical simulation. Moreover, first results

  11. Thermomechanical behavior of graphite and coating materials subjected to a high heat flux

    Energy Technology Data Exchange (ETDEWEB)

    Ioki, K.; Yamada, M.; Nishikawa, M.; Uchikawa, T.; Onozuka, M.; Yamao, H.

    1987-07-01

    This study has been performed for the development of limiter and divertor plates. Their thermal and thermomechanical behavior were examined in heat load experiments with an electron beam facility, and were compared with analysis results. Graphite was proven to have a high thermal shock resistance. Its erosion thickness and thermal contact conductance were also studied. Copper alloy with coating and graphite brazed to metal were tested, and their feasibility was demonstrated for use as limiter and divertor plates of an advanced-type concept.

  12. Divertor experiment for impurity control in DIVA

    International Nuclear Information System (INIS)

    Nagami, Masayuki

    1979-04-01

    Divertor actions of controlling the impurities and the transport of impurity ions in the plasma have been investigated in the DIVA device. Following are the results: (1) The radial transport of impurity ions is not described only by neoclassical theory, but it is strongly influenced by anomalous process. Radial diffusion of impurity ions across the whole minor radius is well described by a neoclassical diffusion superposed by the anomalous diffusion for protons. Due to this anomalous process, which spreads the radial density profile of impurity ions, 80 to 90% of the impurity flux in the plasma outer edge is shielded even in a nondiverted discharge. (2) The divertor reduces the impurity flux entering the main plasma by a factor of 2 to 4. The impurity ions shielded by the scrape-off plasma are rapidly guided into the burial chamber with a poloidal excursion time roughly equal to that of the scrape-off plasma. (3) The divertor reduces the impurity ion flux onto the main vacuum chamber by guiding the impurity ions diffusing from the main plasma into the burial chamber, thereby reducing the plasma-wall interaction caused by diffusing impurity ions at the main vacuum chamber. The impurity ions produced in the burial chamber may flow back to the main plasma through the scrape-off layer. However, roughly only 0.3% of the impurity flux into the scrape-off plasma in the burial chamber penetrates into the main plasma due to the impurity backflow. (4) A slight cooling of the scrape-off plasma with light-impurity injection effectively reduces the metal impurity production at the first wall by reducing the potential difference between the plasma and the wall, thereby reducing the accumulation of the metal impurity in the discharge. Radiation cooling by low-Z impurities in the plasma outer edge, which may become an important feature in future large tokamaks both with and without divertor, is numerically evaluated for carbon, oxygen and neon. (author)

  13. Simulation of the ASDEX divertor performance after hardening

    International Nuclear Information System (INIS)

    Schneider, W.; Lackner, K.; Neuhauser, J.; Wunderlich, R.

    1985-05-01

    Two combined computer models - a fluid description of the plasma scrape-off layer (SOLID) and a Monte-Carlo code for the neutral gas dynamics (DEGAS) - are used to assess changes in the divertor performance expected from the modifications in geometry needed for hardening the ASDEX divertor chamber for long-pulse, high-power heating. Stand-alone DEGAS calculations with assumed fixed scrape-off plasma parameters predict a doubling of the neutral escape probability, which, however, still remains so low, that achievement of the high divertor recycling regime can be expected over roughly the same operational regime as before modifications. This conclusion is also supported by fully self-consistent calculations with the combined model. Due to the reduced divertor, a significant reduction is predicted in the divertor time constant, which is expected to affect transient phenomena. (orig.)

  14. Numerical Calculation of the Peaking Factor of a Water-Cooled W/Cu Monoblock for a Divertor

    Science.gov (United States)

    Han, Le; Chang, Haiping; Zhang, Jingyang; Xu, Tiejun

    2015-09-01

    In order to accurately predict the incident critical heat flux (ICHF, the heat flux at the heated surface when CHF occurs) of a water-cooled W/Cu monoblock for a divertor, the exact knowledge of its peaking factors (fp) under one-sided heating conditions with different design parameters is a key issue. In this paper, the heat conduction in the solid domain of a water-cooled W/Cu monoblock is calculated numerically by assuming the local heat transfer coefficients (HTC) of the cooling wall to be functions of the local wall temperature, so as to obtain fp. The reliability of the calculation method is validated by an experimental example result, with the maximum error of 2.1% only. The effects of geometric and flow parameters on the fp of a water-cooled W/Cu monoblock are investigated. Within the scope of this study, it is shown that the fp increases with increasing dimensionless W/Cu monoblock width and armour thickness (the shortest distance between the heated surface and Cu layer), and the maximum increases are 43.8% and 22.4% respectively. The dimensionless W/Cu monoblock height and Cu thickness have little effect on fp. The increase of Reynolds number and Jakob number causes the increase of fp, and the maximum increases are 6.8% and 9.6% respectively. Based on the calculated results, an empirical correlation on peaking factor is obtained via regression. These results provide a valuable reference for the thermal-hydraulic design of water-cooled divertors. supported by National Magnetic Confinement Fusion Science Program of China (No. 2010GB104005) and Funding of Jiangsu Innovation Program for Graduate Education, China (CXLX12_0170), the Fundamental Research Funds for the Central Universities of China

  15. Limiter and divertor systems - conceptual and mechanical design for Aditya Tokamak upgrade

    International Nuclear Information System (INIS)

    Patel, Kaushal; Rathod, Kulav; Jadeja, Kumarpalsinh A.

    2015-01-01

    Existing Aditya tokamak with limiter configuration is being upgraded into a machine to have both the limiter and divertor configurations. Necessary modifications have been carried out to accommodate divertor coils by replacing the old vacuum vessel with a new circular section vacuum vessel. The upgraded Aditya tokamak will have different set of limiters and divertors, such as Safety limiter, Toroidal Inner limiter, outer limiter of smaller toroidal extent, Upper and lower divertor plates. The limiter and divertor locations inside the Aditya tokamak upgrade are decided based on the numerical simulation of the plasma equilibrium profiles. Initially graphite will be used as plasma facing material (PFM) in all the limiter and divertor plates. The dimensions of the limiter and divertor tiles are decided based on their installation inside the vacuum vessel as well as on the total plasma heat loads (∼ 1 MW) falling on them. Depending upon the heat loads; the thickness of graphite tiles for limiter and divertor plates is estimated. Shaped graphite tiles will be fixed on specially designed support structures made out of SS-304L inside the torus shaped vacuum vessel. In this paper mechanical structural design of limiter and divertor of Aditya Upgrade Tokamak is presented. (author)

  16. A program to evaluate the erosion on the CFC tiles of the ITER divertor

    Energy Technology Data Exchange (ETDEWEB)

    D' Agata, E. [ITER International Team, ITER Joint Work Site, Boltzmannstr 2, 85748 Garching (Germany)], E-mail: elio.dagata@iter.org; Ogorodnikova, O.V. [Association Euratom-CEA, CEA/DSM/DRFC, CEA/Cadarache, F-13108 Saint-Paul-Lez-Durance (France); Tivey, R. [ITER International Team, ITER Joint Work Site, Boltzmannstr 2, 85748 Garching (Germany); Lowry, C.; Schlosser, J. [Association Euratom-CEA, CEA/DSM/DRFC, CEA/Cadarache, F-13108 Saint-Paul-Lez-Durance (France)

    2007-10-15

    The plasma-facing surfaces of the ITER divertor are armoured with tungsten in the upper part of the inner and outer vertical targets, and carbon fibre composite (CFC) in the lower part, the region where the scrape-off layer intercepts the divertor. The CFC in the form of a monoblock in the vertical target is the most loaded part of the plasma-facing surfaces, and hence it is subjected to high erosion and has a significant risk of failure. A program has been developed with the aim of understanding the impact on the erosion lifetime due to a combination of two main effects: the material property variations (particularly pronounced in CFC) and the presence of joining defects. The software allows the evolution of the surface profile of the armour to be predicted and the margin on critical heat flux at the heat-sink-to-coolant interface to be estimated for a range of postulated defects, from start-of-life through to end-of-life of the component. In assessing erosion, the code takes account of geometry and sublimation, and physical and chemical erosion of the CFC armour. The incident angle (a glancing angle of a few degrees) of the particle and heat flux onto the target is taken into account. The program has been validated by comparison with analytical approximations very well validated against experimental data. The code has been developed in the APDL language to operate inside a commercial and certificated finite element program such as ANSYS.

  17. A program to evaluate the erosion on the CFC tiles of the ITER divertor

    International Nuclear Information System (INIS)

    D'Agata, E.; Ogorodnikova, O.V.; Tivey, R.; Lowry, C.; Schlosser, J.

    2007-01-01

    The plasma-facing surfaces of the ITER divertor are armoured with tungsten in the upper part of the inner and outer vertical targets, and carbon fibre composite (CFC) in the lower part, the region where the scrape-off layer intercepts the divertor. The CFC in the form of a monoblock in the vertical target is the most loaded part of the plasma-facing surfaces, and hence it is subjected to high erosion and has a significant risk of failure. A program has been developed with the aim of understanding the impact on the erosion lifetime due to a combination of two main effects: the material property variations (particularly pronounced in CFC) and the presence of joining defects. The software allows the evolution of the surface profile of the armour to be predicted and the margin on critical heat flux at the heat-sink-to-coolant interface to be estimated for a range of postulated defects, from start-of-life through to end-of-life of the component. In assessing erosion, the code takes account of geometry and sublimation, and physical and chemical erosion of the CFC armour. The incident angle (a glancing angle of a few degrees) of the particle and heat flux onto the target is taken into account. The program has been validated by comparison with analytical approximations very well validated against experimental data. The code has been developed in the APDL language to operate inside a commercial and certificated finite element program such as ANSYS

  18. Study of heat fluxes on plasma facing components in a tokamak from measurements of temperature by infrared thermography

    International Nuclear Information System (INIS)

    Daviot, R.

    2010-05-01

    The goal of this thesis is the development of a method of computation of those heat loads from measurements of temperature by infrared thermography. The research was conducted on three issues arising in current tokamaks but also future ones like ITER: the measurement of temperature on reflecting walls, the determination of thermal properties for deposits observed on the surface of tokamak components and the development of a three-dimensional, non-linear computation of heat loads. A comparison of several means of pyrometry, monochromatic, bi-chromatic and photothermal, is performed on an experiment of temperature measurement. We show that this measurement is sensitive to temperature gradients on the observed area. Layers resulting from carbon deposition by the plasma on the surface of components are modeled through a field of equivalent thermal resistance, without thermal inertia. The field of this resistance is determined, for each measurement points, from a comparison of surface temperature from infrared thermographs with the result of a simulation, which is based on a mono-dimensional linear model of components. The spatial distribution of the deposit on the component surface is obtained. Finally, a three-dimensional and non-linear computation of fields of heat fluxes, based on a finite element method, is developed here. Exact geometries of the component are used. The sensitivity of the computed heat fluxes is discussed regarding the accuracy of the temperature measurements. This computation is applied to two-dimensional temperature measurements of the JET tokamak. Several components of this tokamak are modeled, such as tiles of the divertor, upper limiter and inner and outer poloidal limiters. The distribution of heat fluxes on the surface of these components is computed and studied along the two main tokamak directions, poloidal and toroidal. Toroidal symmetry of the heat loads from one tile to another is shown. The influence of measurements spatial resolution

  19. Evaluation of divertor conceptual designs for a fusion power plant

    International Nuclear Information System (INIS)

    Ferrari, M.; Giancarli, L.; Kleefeldt, K.; Nardi, C.; Roedig, M.; Reimann, J.; Salavy, J.F.

    2001-01-01

    In the frame of the preliminary study of plants suitable for the energy production from the fusion power, particular emphasis has been given on the divertor studies. Since a significant percentage of the power generated from the fusion process is absorbed in the divertor, the thermal efficiency of the power conversion cycle requires a high coolant outlet temperature of the divertor, leading to solutions that are different from those adopted for the present experimental fusion plants. Therefore, copper alloys having extremely high thermal conductivity, cannot be used as structural material for this kind of devices. The most suitable coolants to be used in the divertor are water, helium and liquid metals. A conceptual design study has been developed for each of these three fluids, with the aim to evaluate the maximum allowable thermal flux at the divertor target plate and the R and D requirements for each solution. While a water-cooled divertor can be designed with a limited R and D effort, the development of helium or liquid metal cooled divertors requires a more engaging R and D program

  20. Effect of heated length on the Critical Heat Flux of subcooled flow boiling. 2. Effective heated length under axially nonuniform heating condition

    International Nuclear Information System (INIS)

    Kinoshita, Hidetaka; Yoshida, Takuya; Nariai, Hideki; Inasaka, Fujio

    1998-01-01

    Effect of heated length on the Critical Heat Flux (CHF) of subcooled flow boiling with water was experimentally investigated by using direct current heated tube made of stainless steel a part of whose wall thickness was axially cut for realizing nonuniform heat flux condition. The higher enhancement of the CHF was derived for shorter tube length. The effective heated length was determined for the tube under axially nonuniform heat flux condition. When the lower heat flux part below the Net Vapor Generation (NVG) heat flux exists at the middle of tube length, then the effective heated length becomes the tube length downstream the lower heat flux parts. However, when the lower heat flux part is above the NVG, then the effective heated length is full tube length. (author)

  1. Heat Flux Inhibition by Whistlers: Experimental Confirmation

    International Nuclear Information System (INIS)

    Eichler, D.

    2002-01-01

    Heat flux in weakly magnetized collisionless plasma is, according to theoretical predictions, limited by whistler turbulence that is generated by heat flux instabilities near threshold. Observations of solar wind electrons by Gary and coworkers appear to confirm the limit on heat flux as being roughly the product of the magnetic energy density and the electron thermal velocity, in agreement with prediction (Pistinner and Eichler 1998)

  2. A simple heat transfer model for a heat flux plate under transient conditions

    International Nuclear Information System (INIS)

    Ryan, L.; Dale, J.D.

    1985-01-01

    Heat flux plates are used for measuring rates of heat transfer through surfaces under steady state and transient conditions. Their usual construction is to have a resistive layer bounded by thermopiles and an exterior layer for protection. If properly designed and constructed a linear relationship between the thermopile generated voltage and heat flux results and calibration under steady state conditions is straight forward. Under transient conditions however the voltage output from a heat flux plate cannot instantaneously follow the heat flux because of the thermal capacitance of the plate and the resulting time lag. In order to properly interpret the output of a heat flux plate used under transient conditions a simple heat transfer model was constructed and tested. (author)

  3. Development of high thermal flux components for continuous operation in Tokamaks

    International Nuclear Information System (INIS)

    Schlosser, J.; Chappuis, P.; Coston, J.F.; Deschamps, P.; Lipa, M.

    1991-01-01

    High heat flux plasma facing components are under development and appropriate experimental evaluations have been carried out in order to operate during cycles of several hundred seconds. In Tore Supra, a large tokamak with a plasma nominal duration in excess of 30 seconds, solutions are tested that could be later applied to the NET/ITER tokamak, where peaked heat flux values of 15 MW/m 2 on the divertor plates are foreseen. The proposed concept is a swirl square tube design protected with brazed CFC flat tiles. Development programs and validation tests are presented. The tests results are compared with calculations

  4. Anthropogenic heat flux estimation from space

    NARCIS (Netherlands)

    Chrysoulakis, Nektarios; Marconcini, Mattia; Gastellu-Etchegorry, Jean Philippe; Grimmond, C.S.B.; Feigenwinter, Christian; Lindberg, Fredrik; Frate, Del Fabio; Klostermann, Judith; Mitraka, Zina; Esch, Thomas; Landier, Lucas; Gabey, Andy; Parlow, Eberhard; Olofson, Frans

    2016-01-01

    H2020-Space project URBANFLUXES (URBan ANthrpogenic heat FLUX from Earth observation Satellites) investigates the potential of Copernicus Sentinels to retrieve anthropogenic heat flux, as a key component of the Urban Energy Budget (UEB). URBANFLUXES advances the current knowledge of the impacts

  5. ANthropogenic heat FLUX estimation from Space

    NARCIS (Netherlands)

    Chrysoulakis, Nektarios; Marconcini, Mattia; Gastellu-Etchegorry, Jean Philippe; Grimmong, C.S.B.; Feigenwinter, Christian; Lindberg, Fredrik; Frate, Del Fabio; Klostermann, Judith; Mi, Zina; Esch, Thomas; Landier, Lucas; Gabey, Andy; Parlow, Eberhard; Olofson, Frans

    2017-01-01

    The H2020-Space project URBANFLUXES (URBan ANthrpogenic heat FLUX from Earth observation Satellites) investigates the potential of Copernicus Sentinels to retrieve anthropogenic heat flux, as a key component of the Urban Energy Budget (UEB). URBANFLUXES advances the current knowledge of the

  6. Thin Film Heat Flux Sensors: Design and Methodology

    Science.gov (United States)

    Fralick, Gustave C.; Wrbanek, John D.

    2013-01-01

    Thin Film Heat Flux Sensors: Design and Methodology: (1) Heat flux is one of a number of parameters, together with pressure, temperature, flow, etc. of interest to engine designers and fluid dynamists, (2) The measurement of heat flux is of interest in directly determining the cooling requirements of hot section blades and vanes, and (3)In addition, if the surface and gas temperatures are known, the measurement of heat flux provides a value for the convective heat transfer coefficient that can be compared with the value provided by CFD codes.

  7. Thermomechanical behavior of graphite and coating materials subjected to a high heat flux

    International Nuclear Information System (INIS)

    Ioki, K.; Yamada, M.; Nishikawa, M.; Uchikawa, T.; Onozuka, M.; Yamao, H.

    1987-01-01

    This study has been performed for the development of limiter and divertor plates. Their thermal and thermomechanical behavior were examined in heat load experiments with an electron beam facility, and were compared with analysis results. Graphite was proven to have a high thermal shock resistance. Its erosion thickness and thermal contact conductance were also studied. Copper alloy with coating and graphite brazed to metal were tested, and their feasibility was demonstrated for use as limiter and divertor plates of an advanced-type concept. (orig.)

  8. Experimental investigation of heat transport and divertor loads of fusion plasmas in all metal ASDEX upgrade and JET

    International Nuclear Information System (INIS)

    Sieglin, Bernhard A.

    2014-01-01

    This work presents divertor heat load studies conducted at two of the largest tokamaks currently in operation, ASDEX Upgrade and the Joint European Torus (JET). A commonly agreed empirical scaling for the power fall-off length in H-mode obtained in carbon devices is validated in JET with the ILW. Bohm and Gyro-Bohm like models are identified as possible candidates describing the divertor broadening. Quantities for the assessment of the thermal load induced by transient heat loads are defined. JET with the ILW exhibits an on average longer ELM duration as compared to the carbon wall. For identical pedestal conditions the ELM durations in both cases are found to be the same within error bars. The energy fluency is found to depend mainly on the pedestal pressure with a weak dependence on the relative loss in stored energy. This is noteworthy since the current extrapolation to ITER assumes a linear dependence on the relative ELM size.

  9. Deposition of deuterium and metals on divertor tiles in the DIII-D tokamak

    International Nuclear Information System (INIS)

    Walsh, D.S.; Doyle, B.L.; Jackson, G.L.

    1991-01-01

    Hydrogen recycling and impurity influx are important issues in obtaining high confinement discharges in the D3-D tokamak. To reduce metallic impurities in D3-D, 40% of the wall area, including the highest heat flux zones, have been covered with graphite tiles. However erosion, redeposition and hydrogen retention in the tiles, as well as metal transport from the remaining Inconel walls can lead to enhanced recycling and impurity influx. Hydrogen and metal retention in divertor floor tiles have been measured using external ion beam analysis techniques following four campaigns where tiles were exposed to several thousand tokamak discharges. The areal density of deuterium retained following exposure to tokamak plasmas was measured with external nuclear reaction analysis. External proton-induced x-ray emission analysis was used to measure the areal densities of metallic impurities deposited upon the divertor tiles either by sputtering of metallic components during discharges or as contamination during tile fabrication. Measurements for both deuterium and metallic impurities were taken on both the tile surfaces which face the operating plasma and the surfaces on the side of the tiles which form the small gaps separating each of the tiles in the divertor. The highest areal densities of both deuterium and metals were found on the plasma-facing surface near the inner strike point region of each set of divertor tiles. Significant deposits, extending as fast a 1 cm from the plasma-facing and containing up to forty percent of the total divertor deposition, were also observed on the gap-forming surfaces of the tiles

  10. A large divertor manipulator for ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, Albrecht, E-mail: albrecht.herrmann@ipp.mpg.de; Jaksic, Nikola; Leitenstern, Peter; Greuner, Henri; Krieger, Karl; Marné, Pascal de; Oberkofler, Martin; Rohde, Volker; Schall, Gerd

    2015-10-15

    Highlights: • A large divertor manipulator for ASDEX Upgrade is developed and tested. • It allows replacing a relevant part of the divertor by dedicated targets and probes. • Modified solid standard targets. • Electrical and mechanical probes for dedicated investigations. • Test of actively cooled component. - Abstract: In 2013 a new bulk tungsten divertor, Div-III, was installed in ASDEX Upgrade (AUG). During the concept and design phase of Div-III the option of adaptable divertor instrumentation and divertor modification as contribution for divertor investigations in preparation of ITER was given a high priority. To gain flexibility for the test of divertor modifications without affecting the operational space of AUG, the large divertor manipulator, DIM-II, was designed and installed. DIM-II allows to retract 2 out of 128 outer divertor target tiles including the water cooled support structure into a target exchange box and to replace these targets without breaking the vacuum of the AUG vessel. DIM-II is based on a carriage-rail system with a driving rod pushing a front-end with the target module into the divertor position for plasma operation. Three types of front-ends are foreseen for physics investigations: (i) modified standard targets clamped to the standard cooling structure, (ii) dedicated front-ends making use of the whole available volume of about 230 × 160 × 80 mm{sup 3} and (iii) actively cooled/heated targets for cooling water temperatures up to 230 °C. This paper presents the DIM-II design including the FEM calculations for the modified divertor support structure and the front-end options, as well as the test procedure and operation mode.

  11. A procedure for generating quantitative 3-D camera views of tokamak divertors

    International Nuclear Information System (INIS)

    Edmonds, P.H.; Medley, S.S.

    1996-05-01

    A procedure is described for precision modeling of the views for imaging diagnostics monitoring tokamak internal components, particularly high heat flux divertor components. These models are required to enable predictions of resolution and viewing angle for the available viewing locations. Because of the oblique views expected for slot divertors, fully 3-D perspective imaging is required. A suite of matched 3-D CAD, graphics and animation applications are used to provide a fast and flexible technique for reproducing these views. An analytic calculation of the resolution and viewing incidence angle is developed to validate the results of the modeling procedures. The calculation is applicable to any viewed surface describable with a coordinate array. The Tokamak Physics Experiment (TPX) diagnostics for infrared viewing are used as an example to demonstrate the implementation of the tools. For the TPX experiment the available locations are severely constrained by access limitations at the end resulting images are marginal in both resolution and viewing incidence angle. Full coverage of the divertor is possible if an array of cameras is installed at 45 degree toroidal intervals. Two poloidal locations are required in order to view both the upper and lower divertors. The procedures described here provide a complete design tool for in-vessel viewing, both for camera location and for identification of viewed surfaces. Additionally these same tools can be used for the interpretation of the actual images obtained by the actual diagnostic

  12. Physics design and experimental study of tokamak divertor

    International Nuclear Information System (INIS)

    Yan Jiancheng; Gao Qingdi; Yan Longwen; Wang Mingxu; Deng Baiquan; Zhang Fu; Zhang Nianman; Ran Hong; Cheng Fayin; Tang Yiwu; Chen Xiaoping

    2007-06-01

    The divertor configuration of HL-2A tokamak is optimized, and the plasma performance in divertor is simulated with B2-code. The effects of collisionality on plasma-wall transition in the scrape-off layer of divertor are investigated, high performances of the divertor plasma in HL-2A are simulated, and a quasi- stationary RS operation mode is established with the plasma controlled by LHCD and NBI. HL-2A tokamak has been successfully operated in divertor configuration. The major parameters: plasma current I p =320 kA, toroidal field B t =2.2 T, plasma discharger duration T d =1580 ms ware achieved at the end of 2004. The preliminary experimental researches of advanced diverter have been carried out. Design studies of divertor target plate for high power density fusion reactor have been carried out, especially, the physical processes on the surface of flowing liquid lithium target plate. The exploration research of improving divertor ash removal efficiency and reducing tritium inventory resulting from applying the RF ponderomotive force potential is studied. The optimization structure design studies of FEB-E reactor divertor are performed. High flux thermal shock experiments were carried on tungsten and carbon based materials. Hot Isostatic Press (HIP) method was employed to bond tungsten to copper alloys. Electron beam simulated thermal fatigue tests were also carried out to W/Cu bondings. Thermal desorption and surface modification of He + implanted into tungsten have been studied. (authors)

  13. Constrained ripple optimization of Tokamak bundle divertors

    International Nuclear Information System (INIS)

    Hively, L.M.; Rome, J.A.; Lynch, V.E.; Lyon, J.F.; Fowler, R.H.; Peng, Y-K.M.; Dory, R.A.

    1983-02-01

    Magnetic field ripple from a tokamak bundle divertor is localized to a small toroidal sector and must be treated differently from the usual (distributed) toroidal field (TF) coil ripple. Generally, in a tokamak with an unoptimized divertor design, all of the banana-trapped fast ions are quickly lost due to banana drift diffusion or to trapping between the 1/R variation in absolute value vector B ω B and local field maxima due to the divertor. A computer code has been written to optimize automatically on-axis ripple subject to these constraints, while varying up to nine design parameters. Optimum configurations have low on-axis ripple ( 0 ) are lost. However, because finite-sized TF coils have not been used in this study, the flux bundle is not expanded

  14. Fluctuations observed in NBI heated Doublet III divertor discharges

    International Nuclear Information System (INIS)

    Konoshima, Shigeru; Aikawa, Hiroshi; Azumi, Masafumi

    1983-10-01

    A specific type of activity associated with fairly large pulsive energy loss has been observed, predominantly during improved confinement (H-mode) discharges in the NBI heated Doublet III tokamak. Large repetitive bursts of edge recycling light with 2-5ms duration and --10ms intervals appear in the course of increasing βsub(p). The amount of energy released by a single burst is estimated to be at least 2-3% of stored energy. As a result of these periodic energy losses, attained values of plasma energy is evaluated to be depressed as much as 10%. Prior to a burst, large m=n=0 magnetic field oscillations of --20kHz were observed with highly peaked distribution near the divertor region. No other particular activities which might be responsible for either the confinement deterioration or improvement have been found throughout the entire operational space. (author)

  15. Tracking heat flux sensors for concentrating solar applications

    Science.gov (United States)

    Andraka, Charles E; Diver, Jr., Richard B

    2013-06-11

    Innovative tracking heat flux sensors located at or near the solar collector's focus for centering the concentrated image on a receiver assembly. With flux sensors mounted near a receiver's aperture, the flux gradient near the focus of a dish or trough collector can be used to precisely position the focused solar flux on the receiver. The heat flux sensors comprise two closely-coupled thermocouple junctions with opposing electrical polarity that are separated by a thermal resistor. This arrangement creates an electrical signal proportional to heat flux intensity, and largely independent of temperature. The sensors are thermally grounded to allow a temperature difference to develop across the thermal resistor, and are cooled by a heat sink to maintain an acceptable operating temperature.

  16. The edge plasma and divertor in TIBER

    Energy Technology Data Exchange (ETDEWEB)

    Barr, W.L.

    1987-10-16

    An open divertor configuration has been adopted for TIBER. Most recent designs, including DIII-D, NET and CIT use open configurations and rely on a dense edge plasma to shield the plasma from the gas produced at the neutralizer plate. Experiments on ASDEX, PDX, D-III, and recently on DIII-D have shown that a dense edge plasma can be produced by re-ionizing most of the gas produced at the plate. This high recycling mode allows a large flux of particles to carry the heat to the plate, so that the mean energy per particle can be low. Erosion of the plate can be greatly reduced if the average impact energy of the ions at the plate can be reduced to near or below the threshold for sputtering of the plate material. The present configuration allows part of the flux of edge plasma ions to be neutralized at the entrance to the pumping duct so that helium is pumped as well as hydrogen. 7 refs., 3 figs.

  17. The edge plasma and divertor in TIBER

    International Nuclear Information System (INIS)

    Barr, W.L.

    1987-01-01

    An open divertor configuration has been adopted for TIBER. Most recent designs, including DIII-D, NET and CIT use open configurations and rely on a dense edge plasma to shield the plasma from the gas produced at the neutralizer plate. Experiments on ASDEX, PDX, D-III, and recently on DIII-D have shown that a dense edge plasma can be produced by re-ionizing most of the gas produced at the plate. This high recycling mode allows a large flux of particles to carry the heat to the plate, so that the mean energy per particle can be low. Erosion of the plate can be greatly reduced if the average impact energy of the ions at the plate can be reduced to near or below the threshold for sputtering of the plate material. The present configuration allows part of the flux of edge plasma ions to be neutralized at the entrance to the pumping duct so that helium is pumped as well as hydrogen. 7 refs., 3 figs

  18. Critical heat flux, post dry-out and their augmentation

    International Nuclear Information System (INIS)

    Celata, G.P.; Mariani, A.

    1999-01-01

    The report shows the state of art review on the critical heat flux and the post-dryout heat transfer. The work, which is a merge of original researches carried out at the Institute of Thermal Fluid Dynamic of ENEA (National Agency for New Technology, Energy and the Environment) and a thorough review of the recent literature, is divided in four chapters: critical heat flux in subcooled flow boiling; critical heat flux in saturated flow boiling; post-dryout heat transfer; enhancement of critical heat flux and post-dryout heat transfer [it

  19. Fast heat flux modulation at the nanoscale

    OpenAIRE

    van Zwol, P. J.; Joulain, K.; Abdallah, P. Ben; Greffet, J. J.; Chevrier, J.

    2011-01-01

    We introduce a new concept for electrically controlled heat flux modulation. A flux contrast larger than 10 dB is expected with switching time on the order of tens of nanoseconds. Heat flux modulation is based on the interplay between radiative heat transfer at the nanoscale and phase change materials. Such large contrasts are not obtainable in solids, or in far field. As such this opens up new horizons for temperature modulation and actuation at the nanoscale.

  20. Impact of the impurity seeding for divertor protection on the performance of fusion reactors

    Science.gov (United States)

    Siccinio, Mattia; Fable, Emiliano; Angioni, Clemente; Saarelma, Samuli; Scarabosio, Andrea; Zohm, Hartmut

    2017-10-01

    A 0D divertor and scrape-off layer (SOL) model has been coupled to the 1.5D core transport code ASTRA. The resulting numerical tool has been employed for various parameter scans in order to identify the most convenient choices for the operation of electricity producing fusion devices with seeded impurities for the divertor protection. In particular, the repercussions of such radiative species on the main plasma through the fuel dilution have been taken into account. The main result we found is that, when the limits on the maximum tolerable divertor heat flux are enforced, the curves at constant electrical power output are closed on themselves in the R-BT plane, i.e. no improvement would descend from a further increase of R or BT once the maximum has been reached. This occurrence appears as an intrinsic physical limit for all devices where a radiative SOL is needed to deal with the power exhaust. Furthermore, the relative importance of the different power loss channels (e.g. hydrogen radiation, charge exchange, perpendicular transport and impurity radiation), through which the power entering the SOL is dissipated before reaching the target plate, is investigated with our model.

  1. Study on minimum heat-flux point during boiling heat transfer on horizontal plates

    International Nuclear Information System (INIS)

    Nishio, Shigefumi

    1985-01-01

    The characteristics of boiling heat transfer are usually shown by the boiling curve of N-shape having the maximum and minimum points. As for the limiting heat flux point, that is, the maximum point, there have been many reports so far, as it is related to the physical burn of heat flux-controlling type heating surfaces. But though the minimum heat flux point is related to the quench point as the problems in steel heat treatment, the core safety of LWRs, the operational stability of superconducting magnets, the start-up characteristics of low temperature machinery, the condition of vapor explosion occurrence and so on, the systematic information has been limited. In this study, the effects of transient property and the heat conductivity of heating surfaces on the minimum heat flux condition in the pool boiling on horizontal planes were experimentally examined by using liquid nitrogen. The experimental apparatuses for steady boiling, for unsteady boiling with a copper heating surface, and for unsteady boiling with a heating surface other than copper were employed. The boiling curves obtained with these apparatuses and the minimum heat flux point condition are discussed. (Kako, I.)

  2. Physical study of experimental fusion breeder FEB divertor

    International Nuclear Information System (INIS)

    Zhu Yukun; Zhou Xiaobing; Huang Jinhua; Feng Kaiming; Deng Peizhi; Huo Tiejun

    1999-10-01

    The physical study of FEB divertor is presented. In order to improve the impurity control and increase ion-neutral interactions in the divertor, the configuration of the divertor is optimized to be the close type in the engineering design activity compared with the open type in the early conceptual activity. The operation mode of the divertor is designed to be partial detached plasma mode under conditions of combination gas-puffing with impurity injection. The position of gas-puffing is optimized to be at the torus mid-plane with NEWT1D code from the viewpoint of impurity retention and radiation in the scrape-off layer/divertor region. Boron is chosen as the injected impurity. The effect of boron impurity injection is evaluated from the reduced heat load on the divertor target. The plasma pressure drop along the scrape-off layer/divertor region is estimated with the two-point transport model and impurity radiation model in the dynamic gas target concept. The simulation results show that the plasma pressure drop factor f p is not only related to the radiation fraction f rad but also related greatly to the stagnation point density n s

  3. Alternative divertor target concepts for next step fusion devices

    Science.gov (United States)

    Mazul, I. V.

    2016-12-01

    The operational conditions of a divertor target in the next steps of fusion devices are more severe in comparison with ITER. The current divertor designs and technologies have a limited application concerning these conditions, and so new design concepts/technologies are required. The main reasons which practically prevent the use of the traditional motionless solid divertor target are analyzed. We describe several alternative divertor target concepts in this paper. The comparative analysis of these concepts (including the advantages and the drawbacks) is made and the prospects for their practical implementation are prioritized. The concept of the swept divertor target with a liquid metal interlayer between the moving armour and motionless heat-sink is presented in more detail. The critical issues of this design are listed and outlined, and the possible experiments are presented.

  4. Local island divertor experiments on LHD

    International Nuclear Information System (INIS)

    Morisaki, T.; Masuzaki, S.; Komori, A.; Ohyabu, N.; Kobayashi, M.; Feng, Y.; Sardei, F.; Narihara, K.; Tanaka, K.; Ida, K.; Peterson, B.J.; Yoshinuma, M.; Ashikawa, N.; Emoto, M.; Funaba, H.; Goto, M.; Ikeda, K.; Inagaki, S.; Kaneko, O.; Kawahata, K.; Kubo, S.; Miyazawa, J.; Morita, S.; Nagaoka, K.; Nagayama, Y.; Nakanishi, H.; Ohkubo, K.; Oka, Y.; Osakabe, M.; Shimozuma, T.; Shoji, M.; Takeiri, Y.; Sakakibara, S.; Sakamoto, R.; Sato, K.; Toi, K.; Tsumori, K.; Watababe, K.Y.; Yamada, H.; Yamada, I.; Yoshimura, Y.; Motojima, O.

    2005-01-01

    A local island divertor (LID) experiment has begun on LHD, with the aims of controlling edge recycling and improving the plasma confinement. The fundamental divertor functions of the LID have been demonstrated in the recent experiments. From the particle flux profile measurements on the LID head it was found that the particles diffusing out from the core region are well guided along the island separatrix to the LID head. Owing to the closed configuration around the LID head, evidence of the high efficient pumping was observed, together with a strong capacity to screen impurities. The first results of edge modeling using the EMC3-EIRENE code are also presented

  5. Divertor power load studies for attached L-mode single-null plasmas in TCV

    NARCIS (Netherlands)

    Maurizio, R.; Elmore, S.; Fedorczak, N.; Gallo, A.; Reimerdes, H.; Labit, B.; Theiler, C.; Tsui, C. K.; Vijvers, W. A. J.; TCV team,; MST1 Team,

    2018-01-01

    This paper investigates the power loads at the inner and outer divertor targets of attached, Ohmic L-mode, deuterium plasmas in the TCV tokamak, in various experimental situations using an Infrared thermography system. The study comprises variations of the outer divertor leg length and target flux

  6. The ITER Divertor Cassette Project meeting

    International Nuclear Information System (INIS)

    Akiba, M.; Tivey, R.

    2000-01-01

    The Divertor Cassette Project topical meeting took place on April 5-7, 2000 at the JAERI Naka site in Japan. The meeting focused on the progress made by the three parties under task agreements on the development of carbon-fibre composite and tungsten armored high flux plasma-facing components

  7. The control of convection by fuelling and pumping in the JET pumped divertor

    Energy Technology Data Exchange (ETDEWEB)

    Harbour, P J; Andrew, P; Campbell, D; Clement, S; Davies, S; Ehrenberg, J; Erents, S K; Gondhalekar, A; Gadeberg, M; Gottardi, N; Von Hellermann, M; Horton, L; Loarte, A; Lowry, C; Maggi, C; McCormick, K; O` Brien, D; Reichle, R; Saibene, G; Simonini, R; Spence, J; Stamp, M; Stork, D; Taroni, A; Vlases, G [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking

    1994-07-01

    Convection from the scrape-off layer (SOL) to the divertor will control core impurities, if it retains them in a cold, dense, divertor plasma. This implies a high impurity concentration in the divertor, low at its entrance. Particle flux into the divertor entrance can be varied systematically in JET, using the new fuelling and pumping systems. The convection ratio has been estimated for various conditions of operation. Particle convection into the divertor should increase thermal convection, decreasing thermal conduction, and temperature and density gradients along the magnetic field, hence increasing the frictional force and decreasing the thermal force on impurities. Changes in convection in the SOL, caused by gaseous fuelling, have been studied, both experimentally in the JET Mk I divertor and with EDGE2/NIMBUS. 1 ref., 4 figs., 1 tab.

  8. Divertor plasma physics experiments on the DIII-D tokamak

    International Nuclear Information System (INIS)

    Mahdavi, M.A.; Allen, S.L.; Evans, T.E.

    1996-10-01

    In this paper we present an overview of the results and conclusions of our most recent divertor physics and development work. Using an array of new divertor diagnostics we have measured the plasma parameters over the entire divertor volume and gained new insights into several divertor physics issues. We present direct experimental evidence for momentum loss along the field lines, large heat convection, and copious volume recombination during detachment. These observations are supported by improved UEDGE modeling incorporating impurity radiation. We have demonstrated divertor exhaust enrichment of neon and argon by action of a forced scrape off layer (SOL) flow and demonstrated divertor pumping as a substitute for conventional wall conditioning. We have observed a divertor radiation zone with a parallel extent that is an order of magnitude larger than that estimated from a 1-D conduction limited model of plasma at coronal equilibrium. Using density profile control by divertor pumping and pellet injection we have attained H-mode confinement at densities above the Greenwald limit. Erosion rates of several candidate ITER plasma facing materials are measured and compared with predictions of a numerical model

  9. Experimental tests concerning the use of the tungsten-copper couple design concept on the divertor system

    International Nuclear Information System (INIS)

    Brossa, F.; Ghiselli, P.; Tommei, G.; Piatti, G.; Schiller, P.

    1983-01-01

    The technique of brazing tungsten armour to the Cu heat sink to form divertor plates for the INTOR fusion reactor raises fabrication problems to bypass thermal stresses produced by the high thermal flux and the differences in the thermal expansion of the two components. To demonstrate that Cu-W structures are able to withstand the anticipated operating conditions, large Cu-W samples have been prepared by means of different techniques. Samples have been studied before and after thermal cycling (10 4 cycles). (author)

  10. ADX: a high field, high power density, Advanced Divertor test eXperiment

    Science.gov (United States)

    Vieira, R.; Labombard, B.; Marmar, E.; Irby, J.; Shiraiwa, S.; Terry, J.; Wallace, G.; Whyte, D. G.; Wolfe, S.; Wukitch, S.; ADX Team

    2014-10-01

    The MIT PSFC and collaborators are proposing an advanced divertor experiment (ADX) - a tokamak specifically designed to address critical gaps in the world fusion research program on the pathway to FNSF/DEMO. This high field (6.5 tesla, 1.5 MA), high power density (P/S ~ 1.5 MW/m2) facility would utilize Alcator magnet technology to test innovative divertor concepts for next-step DT fusion devices (FNSF, DEMO) at reactor-level boundary plasma pressures and parallel heat flux densities while producing high performance core plasma conditions. The experimental platform would also test advanced lower hybrid current drive (LHCD) and ion-cyclotron range of frequency (ICRF) actuators and wave physics at the plasma densities and magnetic field strengths of a DEMO, with the unique ability to deploy launcher structures both on the low-magnetic-field side and the high-field side - a location where energetic plasma-material interactions can be controlled and wave physics is most favorable for efficient current drive, heating and flow drive. This innovative experiment would perform plasma science and technology R&D necessary to inform the conceptual development and accelerate the readiness-for-deployment of FNSF/DEMO - in a timely manner, on a cost-effective research platform. Supported by DE-FC02-99ER54512.

  11. Status of technology R&D for the ITER tungsten divertor monoblock

    Energy Technology Data Exchange (ETDEWEB)

    Hirai, T., E-mail: takeshi.hirai@iter.org [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Escourbiac, F.; Barabash, V.; Durocher, A.; Fedosov, A.; Ferrand, L.; Jokinen, T.; Komarov, V.; Merola, M.; Carpentier-Chouchana, S. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Arkhipov, N. [Project Center ITER, 1, Building 3, Kurchatov Sq., 123182 Moscow (Russian Federation); Kuznetcov, V.; Volodin, A. [NIIEFA, 3 doroga na Metallostroy, Metallostroy, St. Petersburg 196641 (Russian Federation); Suzuki, S.; Ezato, K.; Seki, Y. [JAEA, Fusion Research and Development Directorate JAEA, 801-1 Mukouyama, Naka, Ibaragi 311-0193 (Japan); Riccardi, B.; Bednarek, M.; Gavila, P. [F4E, c/Josep Pla, n.2, Torres Diagonal Litoral, Edificio B3, E-08019 Barcelona (Spain)

    2015-08-15

    In order to develop and validate the high performance tungsten monoblock technology, the full-tungsten divertor qualification program was defined. As the first step, small-scale mock-ups were manufactured and successfully tested under the required high heat flux loads. The test results demonstrated that the technology is available in Japan and Europe. Post-tests observation of the loaded W monoblocks showed generation of self-castellation – a crack along coolant tube axis. The cause of the self-castellation was discussed and a tungsten material characterization program is being developed with the objective to understand mechanical properties that influence the occurrence of the self-castellation.

  12. Diameter effect on critical heat flux

    International Nuclear Information System (INIS)

    Tanase, A.; Cheng, S.C.; Groeneveld, D.C.; Shan, J.Q.

    2009-01-01

    The critical heat flux look-up table (CHF LUT) is widely used to predict CHF for various applications, including design and safety analysis of nuclear reactors. Using the CHF LUT for round tubes having inside diameters different from the reference 8 mm involves conversion of CHF to 8 mm. Different authors [Becker, K.M., 1965. An Analytical and Experimental Study of Burnout Conditions in Vertical Round Ducts, Aktiebolaget Atomenergie Report AE 177, Sweden; Boltenko, E.A., et al., 1989. Effect of tube diameter on CHF at various two phase flow regimes, Report IPE-1989; Biasi, L., Clerici, G.C., Garriba, S., Sala, R., Tozzi, A., 1967. Studies on Burnout, Part 3, Energia Nucleare, vol. 14, pp. 530-536; Groeneveld, D.C., Cheng, S.C., Doan, T., 1986. AECL-UO critical heat flux look-up table. Heat Transfer Eng., 7, 46-62; Groeneveld et al., 1996; Hall, D.D., Mudawar, I., 2000. Critical heat flux for water flow in tubes - II subcooled CHF correlations. Int. J. Heat Mass Transfer, 43, 2605-2640; Wong, W.C., 1996. Effect of tube diameter on critical heat flux, MaSC dissertation, Ottawa Carleton Institute for Mechanical and Aeronautical Engineering, University of Ottawa] have proposed several types of correlations or factors to describe the diameter effect on CHF. The present work describes the derivation of new diameter correction factor and compares it with several existing prediction methods

  13. Consideration of critical heat flux margin prediction by subcooled or low quality critical heat flux correlations

    International Nuclear Information System (INIS)

    Hejzlar, P.; Todreas, N.E.

    1996-01-01

    The accurate prediction of the critical heat flux (CHF) margin which is a key design parameter in a variety of cooling and heating systems is of high importance. These margins are, for the low quality region, typically expressed in terms of critical heat flux ratios using the direct substitution method. Using a simple example of a heated tube, it is shown that CHF correlations of a certain type often used to predict CHF margins, expressed in this manner, may yield different results, strongly dependent on the correlation in use. It is argued that the application of the heat balance method to such correlations, which leads to expressing the CHF margins in terms of the critical power ratio, may be more appropriate. (orig.)

  14. Deposition of deuterium and metals on divertor tiles in the DIII--D tokamak

    International Nuclear Information System (INIS)

    Walsh, D.S.; Doyle, B.L.; Jackson, G.L.

    1992-01-01

    Hydrogen recycling and impurity influx are important issues in obtaining high confinement discharges in the DIII--D tokamak. To reduce metallic impurities in DIII--D, 40% of the wall area, including the highest heat flux zones, have been covered with graphite tiles. However, erosion, redeposition, and hydrogen retention in the tiles, as well as metal transport from the remaining Inconel walls, can lead to enhanced recycling and impurity influx. Hydrogen and metal retention in divertor floor tiles have been measured using external ion beam analysis techniques following four campaigns where tiles were exposed to several thousand tokamak discharges. The areal density of deuterium retained following exposure to tokamak plasmas was measured with external nuclear reaction analysis. External proton-induced x-ray emission analysis was used to measure the areal densities of metallic impurities deposited upon the divertor tiles either by sputtering of metallic components during discharges or as contamination during tile fabrication. Measurements for both deuterium and metallic impurities were taken on both the tile surfaces which face the operating plasma and the surfaces on the sides of the tiles which form the small gaps separating each of the tiles in the divertor. The highest areal densities of both deuterium (from 2 to 8 x 10 18 atoms/cm 2 ) and metals (from 0.2 to 1 x 10 18 atoms/cm 2 ) were found on the plasma-facing surface near the inner strike point region of each set of divertor tiles. Significant deposits, extending as far as 1 cm from the plasma-facing surface and containing up to 40% of the total divertor deposition, were also observed on the gap-forming surfaces of the tiles

  15. Effects of low-Z and high-Z impurities on divertor detachment and plasma confinement

    Directory of Open Access Journals (Sweden)

    H.Q. Wang

    2017-08-01

    Full Text Available The impurity-seeded detached divertor is essential for heat exhaust in ITER and other reactor-relevant devices. Dedicated experiments with injection of N2, Ne and Ar have been performed in DIII-D to assess the impact of the different impurities on divertor detachment and confinement. Seeding with N2, Ne and Ar all promote divertor detachment, greatly reducing heat flux near the strike point. The upstream plasma density at the onset of detachment decreases with increasing impurity-puffing flow rates. For all injected impurity species, the confinement and pedestal pressure are correlated with the impurity content and the ratio of separatrix loss power to the l-H transition threshold power. As the divertor plasma approaches detachment, the high-Z impurity seeding tends to degrade the core confinement owing to the increased core radiation. In particular, Ar injection with up to 50% of the injected power radiating in the core cools the pedestal and core plasmas, thus significantly degrading the confinement. As for Ne seeding, medium confinement with H98∼0.8 can be maintained during the detachment phase with the pedestal temperature being reduced by about 50%. In contrast, in the N2 seeded plasmas, radiation is predominately confined in the boundary plasma, which leads to less effect on the confinement and pedestal. In the case of strong N2 gas puffing, the confinement recovers during the detachment, from ∼20% reduction at the onset of the detachment to greater than unity comparable to that before the seeding. The core and pedestal temperatures feature a reduction of 30% from the initial attached phase and remain nearly constant during the detachment phase. The improvement in confinement appears to arise from the increase in pedestal and core density despite the temperature reduction.

  16. Measurement of Critical Heat Flux Using the Transient Inverse Heat Conduction Method in Spray cooling

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeung Chan [Andong Nat’l Univ., Andong (Korea, Republic of)

    2016-10-15

    A study on the measurement of critical heat flux using the transient inverse heat conduction method in spray cooling was performed. The inverse heat conduction method estimates the surface heat flux or temperature using a measured interior temperature history. The effects of the measuring time interval and location of temperature measurement on the measurement of critical heat flux were primarily investigated. The following results were obtained. The estimated critical heat flux decreased as the time interval of temperature measurement increased. Meanwhile, the effect of measurement location on critical heat flux was not significant. It was also found, from the experimental results, that the critical superheat increased as the measurement location of thermocouple neared the heat transfer surface.

  17. Measurement of Critical Heat Flux Using the Transient Inverse Heat Conduction Method in Spray cooling

    International Nuclear Information System (INIS)

    Kim, Yeung Chan

    2016-01-01

    A study on the measurement of critical heat flux using the transient inverse heat conduction method in spray cooling was performed. The inverse heat conduction method estimates the surface heat flux or temperature using a measured interior temperature history. The effects of the measuring time interval and location of temperature measurement on the measurement of critical heat flux were primarily investigated. The following results were obtained. The estimated critical heat flux decreased as the time interval of temperature measurement increased. Meanwhile, the effect of measurement location on critical heat flux was not significant. It was also found, from the experimental results, that the critical superheat increased as the measurement location of thermocouple neared the heat transfer surface.

  18. A technical basis for the flux corrected local conditions critical heat flux correlation

    International Nuclear Information System (INIS)

    Luxat, J.C.

    2008-01-01

    The so-called 'flux-corrected' local conditions CHF correlation was developed at Ontario Hydro in the 1980's and was demonstrated to successfully correlate the Onset of Intermittent Dryout (OID) CHF data for 37-element fuel with a downstream-skewed axial heat flux distribution. However, because the heat flux correction factor appeared to be an ad-hoc, albeit a successful modifying factor in the correlation, there was reluctance to accept the correlation more generally. This paper presents a thermalhydraulic basis, derived from two-phase flow considerations, that supports the appropriateness of the heat flux correction as a local effects modifying factor. (author)

  19. High heat flux cooling for accelerator targets

    International Nuclear Information System (INIS)

    Silverman, I.; Nagler, A.

    2002-01-01

    Accelerator targets, both for radioisotope production and for high neutron flux sources generate very high thermal power in the target material which absorbs the particles beam. Generally, the geometric size of the targets is very small and the power density is high. The design of these targets requires dealing with very high heat fluxes and very efficient heat removal techniques in order to preserve the integrity of the target. Normal heat fluxes from these targets are in the order of 1 kw/cm 2 and may reach levels of an order of magnitude higher

  20. In situ measurement of erosion/deposition in the DIII-D divertor by colorimetry

    International Nuclear Information System (INIS)

    Weschenfelder, F.; Wienhold, P.; Winter, J.

    1996-01-01

    Colorimetry was introduced into the DIII-D tokamak to measure in situ the growth and erosion of transparent wall coatings (a-C:H) on the divertor. The colorimetric measurement system consisting of a halogen light source, a set of three filters and a black/white camera is described together with a first erosion measurement. An insertable graphite sample with a diameter of 4.7 cm was precoated with a 300 nm thick amorphous carbon film and was exposed in the divertor for several discharges with its surface coplanar to the surrounding graphite tiles. For each of the discharges the plasma strike point was moved onto the sample for 1 s to erode the coating. Between the discharges a camera signal with each filter was recorded and the film thickness was evaluated along a radial line across the DIMES sample. Thus it has been possible for the first time to measure erosion and deposition of divertor material in situ and shot-by-shot. The average peak heat flux with the strike point on DIMES was about 110 W cm -2 . The measurement shows a strong decrease in the film thickness almost over the entire sample with an average erosion rate of ∼ 9 nm s -1 . (Author)