WorldWideScience

Sample records for district heating sector

  1. Efficiency potential in the district heating sector. Final report

    International Nuclear Information System (INIS)

    Agrell, P.; Bogetoft, P.; Fristrup, P.; Munksgaard, J.; Pade, L.L.

    2003-10-01

    This report is the final documentation for the research project 'District heating prices in a liberalised energy market - benchmarking the production of combined heat and power'. The project compares activities for almost 300 companies, members of the Danish District Heating Society. The main aim of the analyses has been to uncover the saving potential by comparing each individual company to the most efficient companies in the sector. The variable costs have been studied, amounting to almost 7 billion Danish kroner a year, and the analyses found saving potential ranging from 5% to 60% dependent on the expectations to flexibility assigned to the individual companies. The data used are not available for the public as they exceed the Danish District Heating Society's annual statistics. (BA)

  2. District heating

    International Nuclear Information System (INIS)

    1989-03-01

    The papers presented at this meeting dealt with an international comparison of district heating, the Swiss district heating network, political aspects of nuclear district heating, nuclear and non-nuclear sources for district heating. 17 figs., 6 tabs

  3. Link between intermittent electrical energy sources and district heating sector

    DEFF Research Database (Denmark)

    Dominkovic, Dominik Franjo

    2016-01-01

    Energy has always been one of the key challenges in planning of societies' development worldwide. The COP conference in Paris in December 2015 has shown unprecedented mutual understanding of harmful consequences climate change can cause. Integrating power and heating sectors in an efficient way...

  4. Simulating conditions for combined heat and power in the Swedish district heating sector

    International Nuclear Information System (INIS)

    Knutsson, David

    2005-01-01

    The most important issues in the European energy sector today are how to increase competitiveness on the energy markets, reduce both CO2 emissions and dependence on imported fuels. These issues are also important aspects of Swedish energy policy. In Sweden, the district heating (DH) sector has commonly been used to achieve Swedish energy policy goals. However, the ongoing integration and deregulation of the energy markets in Europe now means that the Swedish DH sector can also play an important role in achieving international targets. This thesis investigates the extent to which the Swedish DH sector can contribute to compliance with current energy policy targets, both international and Swedish. The study consisted of simulations of the Swedish DH sector response to various policy instruments in a model that takes the local features of virtually all Swedish DH systems into account. The findings show, for example, that there is great potential for combined heat and power (CHP) generation in the Swedish DH sector. By exporting this CHP electricity to other European countries with less effective and fossil dependent power generation plants, the CO2 emissions from the European energy sector could be substantially reduced. This would also result in increased security of supply and competitiveness in the EU, since fuel use would be more effective. In Sweden, increased CHP generation would also be a way of maintaining an effective national security of supply of power

  5. District heating

    International Nuclear Information System (INIS)

    2005-01-01

    By request of the Dutch Lower House the Netherlands Court of Audit examined the profitability or loss-making of district heating projects between 2001 and 2003. District heating supplies heat to consumers for heating their houses and providing warm tap water. The heat is supplied via warm water that runs through a network of pipes. In the Netherlands, about 250,000 households use district heating. The request by the Dutch Lower House to conduct research on district heating coheres with the initiative District Heating Bill. The bill aims to legally guarantee the supply and affordability of heat for consumers of district heating. [mk] [nl

  6. Analysis of energy development sustainability: The example of the lithuanian district heating sector

    International Nuclear Information System (INIS)

    Kveselis, Vaclovas; Dzenajavičienė, Eugenija Farida; Masaitis, Sigitas

    2017-01-01

    Today, sustainable energy development is one of key issues on European development agenda. The article describes one of sustainable energy development promoting tool - the eco-labelling scheme for district heating and cooling systems elaborated within the framework of Intelligent Energy for Europe program project “Ecoheat4cities” and partially funded by European Agency for Competitiveness and Innovation. The scheme is based on measured energy and environmental performance data of the district heating and cooling system and considers primary non-renewable energy usage together with the share of renewable energy and carbon dioxide emissions calculated using life-cycle analysis methodology. The “power bonus” approach is used for performance indicators of the heat generated in cogeneration installations. An analysis of a number of Lithuanian district heating companies using elaborated labelling criteria shows positive trends towards fulfilling Lithuania's energy policy goals. The labelling scheme gives opportunity for policy makers and urban planners to compare different heat supply options and decide upon exploiting district heating advantages and benefits for reaching EU energy and environment policy goals. - Highlights: • Overview of Lithuania's district heating sector was performed via main sustainability criteria. • Developing to greener and more efficient state was disclosed via analysis of three years activity results. • Green labelling may help district heating companies to maintain existing and attract new potential consumers.

  7. District heating in Switzerland

    International Nuclear Information System (INIS)

    Herzog, F.

    1991-01-01

    District heating has been used in Switzerland for more than 50 years. Its share of the heat market is less than 3% today. An analysis of the use of district heating in various European countries shows that a high share of district heating in the heat market is always dependent on ideal conditions for its use. Market prospects and possible future developments in the use of district heating in Switzerland are described in this paper. The main Swiss producers and distributors of district heating are members of the Association of District Heating Producers and Distributors. This association supports the installation of district heating facilities where ecological, energetical and economic aspects indicate that district heating would be a good solution. (author) 2 tabs., 6 refs

  8. District heating in sequential energy supply

    International Nuclear Information System (INIS)

    Persson, Urban; Werner, Sven

    2012-01-01

    Highlights: ► European excess heat recovery and utilisation by district heat distribution. ► Heat recovery in district heating systems – a structural energy efficiency measure. ► Introduction of new theoretical concepts to express excess heat recovery. ► Fourfold potential for excess heat utilisation in EU27 compared to current levels. ► Large scale excess heat recovery – a collaborative challenge for future Europe. -- Abstract: Increased recovery of excess heat from thermal power generation and industrial processes has great potential to reduce primary energy demands in EU27. In this study, current excess heat utilisation levels by means of district heat distribution are assessed and expressed by concepts such as recovery efficiency, heat recovery rate, and heat utilisation rate. For two chosen excess heat activities, current average EU27 heat recovery levels are compared to currently best Member State practices, whereby future potentials of European excess heat recovery and utilisation are estimated. The principle of sequential energy supply is elaborated to capture the conceptual idea of excess heat recovery in district heating systems as a structural and organisational energy efficiency measure. The general conditions discussed concerning expansion of heat recovery into district heating systems include infrastructure investments in district heating networks, collaboration agreements, maintained value chains, policy support, world market energy prices, allocation of synergy benefits, and local initiatives. The main conclusion from this study is that a future fourfold increase of current EU27 excess heat utilisation by means of district heat distribution to residential and service sectors is conceived as plausible if applying best Member State practice. This estimation is higher than the threefold increase with respect to direct feasible distribution costs estimated by the same authors in a previous study. Hence, no direct barriers appear with

  9. VII international district heating conference

    International Nuclear Information System (INIS)

    1988-01-01

    The proceedings of the 7th International District Heating Conference contain the full texts of the 89 presented papers of which 11 fall under the INIS Subject Scope. The conference met in seven sessions and dealt with the following problem areas: design and optimization of systems of district heating, integration of the power system and the district heating systems, cooperation of nuclear and fossil burning sources in district heating systems, the use of specific nuclear power plants for heating purposes, questions of the control of systems of district heating, the development of components of heating networks, the reliability and design of heat supply pipes. (Z.M.)

  10. Kaliningrad regional district heating network 2004-2006. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-06-15

    This report concerns: Kaliningrad Regional District Heating Network project which was implemented from 2004 to 2006. The task of the project was to establish and operate an association for district heating companies in the region in order to transfer and distribute district heating know-how to the sector and through activities strengthen the sector. The long term aim was to contribute to establishment of an association to continue as a real association for the heat supply companies in the region. (au)

  11. Sparse district-heating in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Stefan Forsaeus [SP Technical Research Institute of Sweden, Building Technology and Mechanics, P.O. Box 24036, SE-400 22 Goeteborg (Sweden); Reidhav, Charlotte [Chalmers University of Technology, Department of Civil and Environmental Engineering, SE-412 96 Goeteborg (Sweden); Lygnerud, Kristina [Goeteborg University, School of Business, Economics and Law, Department of Business Administration, P.O. Box 610, SE-405 30 Goeteborg (Sweden); Werner, Sven [Chalmers University of Technology, Department of Energy and Environment, SE-412 96 Goeteborg (Sweden)

    2008-07-15

    This paper presents a review of the sparse district-heating research programme undertaken in Sweden between 2002 and 2006. The goal of the programme was to increase the future competitiveness for district heat in low heat density areas, e.g., suburban single-family houses and small villages. Such areas are unfavourable, since revenues from heat sold are low compared with the investment cost for the local distribution network. In Sweden, district heat has a dominant position in the heat market for residential and service-sector buildings. In order for the business to grow, it is necessary to increase the rate of expansion in the detached-house segment. This is why the programme was initiated. The extent of the programme was set at EUR 3.6 million with equal financing from the Swedish District-Heating Association and the Swedish Energy-Agency. The research was carried out in three phases: a state of the art survey; a development phase focused on productivity gains where new research on both technology and customer interaction was performed; and finally a demonstration phase where new methods were tested in full-scale field operation. The programme has shown that the Swedish district-heating industry needs to adjust in order to reach a higher profitability for sparse district-heating investments. Tradition from large-scale high-density district heating is hard to scale to fit sparse district-heating systems. For example, the construction becomes very labour intensive and the industry is weak when it comes to market-oriented business logic, sales and private customer interaction. Innovation seems to be a way forward and active management of innovations is a way to create increased value of the investments. Other keys to improving the profitability of sparse district-heating investments are more efficient working routines (resulting in higher productivity) and revised ways of customer communications. These seem more important than increasing efficiency in district-heating

  12. Nuclear district heating

    International Nuclear Information System (INIS)

    Ricateau, P.

    1976-01-01

    An economic study of nuclear district heating is concerned with: heat production, its transmission towards the area to be served and the distribution management towards the consumers. Foreign and French assessments show that the high cost of now existing techniques of hot water transport defines the competing limit distance between the site and township to be below some fifty kilometers for the most important townships (provided that the fuel price remain stationary). All studies converge towards the choice of a high transport temperature as soon as the distance is of some twenty kilometers. As for fossile energy saving, some new possibilities appear with process heat reactors; either PWR of about 1000MWth for large townships, or pool-type reactors of about 100MWth when a combination with an industrial steam supply occurs [fr

  13. District heating versus local heating - Social supportability

    International Nuclear Information System (INIS)

    Matei, Magdalena; Enescu, Diana; Varjoghie, Elena; Radu, Florin; Matei, Lucian

    2004-01-01

    business practices can be improved in district heating?; - Benefits and objectives of competition and privatization. A large number of DH systems in Romania face serious financial, marketing or technical problems. Uncompetitive tariffs and inadequate cost recovery have significantly damaged DH systems. This has a deeply negative impact on municipal budgets and on the viability of DH systems. 20% from the consumers disconnected from the DH systems for various reasons. The national reference tariff do not take into consideration the real economic performances of the DH systems. The lack of consumption control and consumption-based billing drive towards increasing the DH systems crisis. The consumers have to pay the technical, commercial and economic loses of the existing DH systems, so their supportability has continuously decreased. The Government offered every year important subsidies for DH companies, as well as social helps for the heating of the low income families. The real problem is to not spend the public founds covering the losses of some not viable DH systems, managed by state own companies/authorities instead of use this money to help the low income family to pay their contribution for the rehabilitation/construction of an efficient heating system. Gas versus district heating tariffs represents a key factor for everyone's decision to prefer district heating or local heating. The Government has the responsibility to inform the population regarding the future evolution on long term power, heat and gas tariffs in order to help the population to decide what is the most sustainable heating system. Systematic restructuring and investment in efficient technologies are essential for the actual DH systems. This could be made only by a legal/institutional reform which will create the environment for a commercial operations .There is necessary to create the framework for private sector participation stimulation. Only by improving the ownership/management structures could

  14. Heat distribution and the future competitiveness of district heating

    Energy Technology Data Exchange (ETDEWEB)

    Persson, Urban; Werner, Sven [School of Business and Engineering, Halmstad University, PO Box 823, SE-30118 Halmstad (Sweden)

    2011-03-15

    The competitiveness of present and future district heating systems can be at risk when residential and service sector heat demands are expected to decrease in the future. In this study, the future competitiveness of district heating has been examined by an in depth analysis of the distribution capital cost at various city characteristics, city sizes, and heat demands. Hereby, this study explores an important market condition often neglected or badly recognised in traditional comparisons between centralised and decentralised heat supply. By a new theoretical approach, the traditional and empirical expression for linear heat density is transformed into an analytical expression that allows modelling of future distribution capital cost levels also in areas where no district heating exists today. The independent variables in this new analytical expression are population density, specific building space, specific heat demand and effective width. Model input data has primarily been collected from national and European statistical sources on heat use, city populations, city districts and residential living areas. Study objects were 83 cities in Belgium, Germany, France, and the Netherlands. The average heat market share for district heat within these cities was 21% during 2006. The main conclusion is that the future estimated capital costs for district heat distribution in the study cities are rather low, since the cities are very dense. At the current situation, a market share of 60% can be reached with a marginal distribution capital cost of only 2.1 EUR/GJ, corresponding to an average distribution capital cost of 1.6 EUR/GJ. The most favourable conditions appear in large cities and in inner city areas. In the future, there is a lower risk for reduced competitiveness due to reduced heat demands in these areas, since the increased distribution capital cost is low compared to the typical prices of district heat and competing heat supply. However, district heating will lose

  15. District heating in greater Stockholm

    International Nuclear Information System (INIS)

    In Greater Stockholm more than ten municipalities operate more or less extensive district heating networks, whereas a couple of municipalities have still not decided in principle what form of heating will be employed in the future. About 1,2 million people live and work in these municipalities, which together occupy an area of about 1500 km 2 . In this general survey the planning of the extensive work in the municipalities and the alternatives of heat systems in Greater Stockholm, including large integrated district heating systems based on nuclear dual-purpose plants as well as systems based on fossil fuels and several combined plants are discussed. (M.S.)

  16. Boise geothermal district heating system

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, P.J.

    1985-10-01

    This document describes the Boise geothermal district heating project from preliminary feasibility studies completed in 1979 to a fully operational system by 1983. The report includes information about the two local governments that participated in the project - the City of Boise, Idaho and the Boise Warm Springs Water District. It also discusses the federal funding sources; the financial studies; the feasibility studies conducted; the general system planning and design; design of detailed system components; the legal issues involved in production; geological analysis of the resource area; distribution and disposal; the program to market system services; and the methods of retrofitting buildings to use geothermal hot water for space heating. Technically this report describes the Boise City district heating system based on 170/sup 0/F water, a 4000 gpm production system, a 41,000 foot pipeline system, and system economies. Comparable data are also provided for the Boise Warm Springs Water District. 62 figs., 31 tabs.

  17. National district-heating program: generic city district-heating and cooling system from cogeneration retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Davis, H.; Grammel, S.; Kuzanek, J.; Levine, E.

    1981-02-01

    A study, designed to aid in evaluating the feasibility of a district heating and cooling system that uses heat supplied by existing electric generating plants retrofitted for cogeneration, is presented. Based on thermal demands of a metropolitan area, the District Heating and Cooling System (DHCS) model estimates the cost of the retrofit. Environmental impact and the potential for scarce-fuel savings also are assessed by this model. The computer program used is the District Heating Strategy Model (DHSM). Section 2 identifies metropolitan demand sectors and describes the data acquisition method. Section 3 defines thermal energy supply sources and shows how each is located. Program output is summarized in terms of financial data, electrical and thermal loads, and a ranking of existing power plants. Section 4 assesses air pollutant emissions and DHCS fuel-use requirements. Finally, Sec. 5 considers the economics of the DHCS and its costs vs benefits.

  18. Heat pumps in district heating networks

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Markussen, Wiebke Brix; Elmegaard, Brian

    In the current Danish energy system, the majority of electricity and heat is produced in combined heat and power plants. With increasing shares of intermittent renewable power production, it becomes a challenging task to match power and heat production, as heat demand and production capacity...... constraints limit the power plants. Efficient heat pumps can be used to decouple the constraints of electricity and heat production, while maintaining the high energy efficiency needed to match the politically agreed carbon emission goals. The requirements in terms of COP, location, capacity and economy...... are calculated using an energy system model which includes power plants, heat pumps and district heating consumption profiles. The model is developed with focus on accurate representation of the performance of the units in different locations and operating modes. The model can assist in investment decisions...

  19. Demonstration project in Volgograd on transfer of know-how from the district heating sector in Denmark to Russia. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-08-01

    A demonstration project on district heating know-how has been financed by the Danish Technical Assistance Programme administrated by the Danish Energy Agency. A demonstration project in Volgograd was approved, with a budget of only 200.000 DKK (180.000 Rbl). The administration of the project, from fact finding to the final report, has been very efficient in particular to other technical assistance programmes. Although the total budget is low only around 15% of the manpower has been used on administration. The transfer of specific technical experience can be summarized in the following: Installation of small decentralized heat exchanger units for preparation of hot water; Construction of low-cost decentralized heat exchanger installations for preparation of hot water; Installation of thermostatic valves; Installation of small substations for heating and hot water; Use of drain pumps for draining under constructions of district heating pipes to prevent outside corrosion; Design principles for construction and rehabilitation of concrete duct systems with internal and outside draining; Design principles for preinsulated pipes; Principles for monitoring the quality of supply in a local district heating network at the lowest costs by monitoring the critical differential pressure. (EG)

  20. Woodfuel procurement strategies of district heating plants

    International Nuclear Information System (INIS)

    Roos, A.; Bohlin, F.; Hektor, B.; Hillring, B.

    2003-01-01

    Woodfuel use in the Swedish district heating sector increased significantly from 1985 to 1999. This study analysed strategies and considerations concerning woodfuel procurement in district heating plants. Priorities and concerns in the industry involved an increased woodfuel share, ambitions to create an environmental image, cost minimisation, awareness about the role of energy policies for fuel choice, improvement of woodfuel quality and the ambition to maintain a competitive woodfuel market with several suppliers. Factor analysis yielded five dimensions in the woodfuel procurement strategies among the district heating companies: (1) increased woodfuel use; (2) import; (3) spot market woodfuel purchases; (4) focus on refined woodfuels; and (5) using price only when deciding whether to use woodfuels or other fuels. Five clusters were defined along the three strategy dimensions (1)-(3). The clusters differed concerning size, experiences from the introduction of woodfuels, perceptions about woodfuels and strategies employed to date. This paper describes different strategies that the district heating companies apply on the woodfuel market. The conclusion is that policies should consider this diversity in procurement strategies, mitigate their negative side-effects and assist to make them cost-effective. (author)

  1. Smart energy systems and 4th generation district heating

    DEFF Research Database (Denmark)

    Lund, Henrik; Duic, Neven; Østergaard, Poul Alberg

    2016-01-01

    This editorial gives an introduction to the important relationship between Smart Energy Systems and 4th Generation District Heating and presents a number of selected papers from the 1st International Conference on the topic. All of the papers elaborate on or otherwise contribute to the theoretical...... for the active inclusion of the heating and cooling sectors. The concept of 4th Generation District Heating emphasizes that district heating and cooling are both important elements but also technologies that have to be developed further into a 4th generation version to be able to fulfil their roles in future...

  2. Renewable energy in the Lithuanian heating sector

    International Nuclear Information System (INIS)

    Konstantinaviciute, Inga; Bobinaite, Viktorija; Tarvydas, Dalius; Gatautis, Ramunas

    2013-01-01

    The paper analyses the role of renewable energy sources (RES) in the Lithuanian heating sector and the existing support measures. RES consumption has been continuously growing in Lithuania. During the period of 2000–2009, RES used for heat production in the district heating sector increased more than 4 times. Wood and wood products have been the most widely used RES for heat production (RES-H). The lower prices were one of the main reasons which motivated district heating companies to switch fuel to biomass. At the same time subsidies, soft loans, EU Structural Funds for 2007–2013 and some fiscal measures, which are currently available for RES-H promotion, also have some impact on the increase of RES consumption. However, seeking to achieve a 23% national RES target, additional support measures are essential. A qualitative analysis based on the selected set of criteria and consultation with stakeholders showed that energy policy package for RES promotion in the Lithuanian heating sector could encompass the following measures: tax relieves (differentiated VAT and personal income tax breaks), subsidies, soft loans, standardization, support for research, development and demonstration. These measures are market-oriented and meet cost efficiency and low transaction costs criteria. - Highlights: • Existing support measures are not strongly motivating market players. • In order to meet ambitious 23% targets consistent promotion policy package is required. • The proposed package could consist of 4 instruments: tax related, soft loans, standardization and support for RD and D. • The proposed support measures are market oriented and meets cost efficiency and low transaction costs criteria. • There is no single measure that is fairly suitable to support RES-H

  3. National energy policies: Obstructing the reduction of global CO2 emissions? An analysis of Swedish energy policies for the district heating sector

    International Nuclear Information System (INIS)

    Difs, Kristina

    2010-01-01

    The effect of national energy policies on a local Swedish district heating (DH) system has been studied, regarding the profitability of new investments and the potential for climate change mitigation. The DH system has been optimised regarding three investments: biomass-fuelled CHP (bio CHP), natural gas-fuelled combined cycle CHP (NGCC CHP) and biomass-fuelled heat-only boiler (bio HOB) in two scenarios (with or without national taxes and policy instruments). In both scenarios EU's tradable CO 2 emission permits are included. Results from the study show that when national policies are included, the most cost-effective investment option is the bio CHP technology. However, when national taxes and policy instruments are excluded, the DH system containing the NGCC CHP plant has 30% lower system cost than the bio CHP system. Regardless of the scenario and when coal condensing is considered as marginal electricity production, the NGCC CHP has the largest global CO 2 reduction potential, about 300 ktonne CO 2 . However, the CO 2 reduction potential is highly dependent on the marginal electricity production. Demonstrated here is that national policies such as tradable green certificates can, when applied to DH systems, contribute to investments that will not fully utilise the DH systems' potential for global CO 2 emissions reductions. - Research highlights: →Swedish energy policies are promoting biomass fuelled electricity generating technologies over efficient fossil fuel electricity generating technologies. →An efficient fossil fuel technology like the natural gas combine cycle CHP technology with high power-to-heat ratio has potential to reduce the global CO 2 emissions more than a biomass fuelled electricity generating technology. →Swedish energy policies such as tradable green certificates for renewable electricity can, when applied to district heating systems, contribute to investments that will not fully utilise the district heating systems potential for

  4. Groundwater and geothermal: urban district heating applications

    Energy Technology Data Exchange (ETDEWEB)

    Mounts, R.; Frazier, A.; Wood, E.; Pyles, O.

    1982-01-01

    This report describes how several cities use groundwater and geothermal energy in district heating systems. It begins with groundwater, introducing the basic technology and techniques of development, and describing two case studies of cities with groundwater-based district heating systems. The second half of the report consists of three case studies of cities with district heating systems using higher temperature geothermal resources.

  5. Nuclear power for district heating

    International Nuclear Information System (INIS)

    Lyon, R.B.; Sochaski, R.O.

    1975-09-01

    Current district heating trends are towards an increasing use of electricity. This report concerns the evaluation of an alternative means of energy supply - the direct use of thermal energy from CANDU nuclear stations. The energy would be transmitted via a hot fluid in a pipeline over distances of up to 40 km. Advantages of this approach include a high utilization of primary energy, with a consequent reduction in installed capacity, and load flattening due to inherent energy storage capacity and transport delays. Disadvantages include the low load factors for district heating, the high cost of the distribution systems and the necessity for large-scale operation for economic viability. This requirement for large-scale operation from the beginning could cause difficulty in the implementation of the first system. Various approaches have been analysed and costed for a specific application - the supply of energy to a district heating load centre in Toronto from the location of the Pickering reactor station about 40 km away. (author)

  6. Evaluation of Excess Heat Utilization in District Heating Systems by Implementing Levelized Cost of Excess Heat

    Directory of Open Access Journals (Sweden)

    Borna Doračić

    2018-03-01

    Full Text Available District heating plays a key role in achieving high primary energy savings and the reduction of the overall environmental impact of the energy sector. This was recently recognized by the European Commission, which emphasizes the importance of these systems, especially when integrated with renewable energy sources, like solar, biomass, geothermal, etc. On the other hand, high amounts of heat are currently being wasted in the industry sector, which causes low energy efficiency of these processes. This excess heat can be utilized and transported to the final customer by a distribution network. The main goal of this research was to calculate the potential for excess heat utilization in district heating systems by implementing the levelized cost of excess heat method. Additionally, this paper proves the economic and environmental benefits of switching from individual heating solutions to a district heating system. This was done by using the QGIS software. The variation of different relevant parameters was taken into account in the sensitivity analysis. Therefore, the final result was the determination of the maximum potential distance of the excess heat source from the demand, for different available heat supplies, costs of pipes, and excess heat prices.

  7. Rehabilitation of district heating networks

    Energy Technology Data Exchange (ETDEWEB)

    Ottosson, Peter [AaF-Energikonsult Syd AB (Sweden)

    1996-11-01

    Often the choice is between reparation or exchange of a damaged section of the network. If the exchange is based on the wrong assumptions, large sections of undamaged pipelines could be removed. Most important for the district heating company is to decide which strategy to use for the future exchange of the pipelines. Whichever strategy used, it has to based on an assessment of the network and/or assumptions based on that assessment. The question if it is possible extend the life span of the pipelines arises. What is the most economical choice, the exchange or the renovation. (au)

  8. SECURE nuclear district heating plant

    International Nuclear Information System (INIS)

    Nilsson; Hannus, M.

    1978-01-01

    The role foreseen for the SECURE (Safe Environmentally Clean Urban REactor) nuclear district heating plant is to provide the baseload heating needs of primarily the larger and medium size urban centers that are outside the range of waste heat supply from conventional nuclear power stations. The rationale of the SECURE concept is that the simplicity in design and the inherent safety advantages due to the use of low temperatures and pressures should make such reactors economically feasible in much smaller unit sizes than nuclear power reactors and should make their urban location possible. It is felt that the present design should be safe enough to make urban underground location possible without restriction according to any criteria based on actual risk evaluation. From the environmental point of view, this is a municipal heat supply plant with negligible pollution. Waste heat is negligible, gaseous radioactivity release is negligible, and there is no liquid radwaste release. Economic comparisons show that the SECURE plant is competitive with current fossil-fueled alternatives. Expected future increase in energy raw material prices will lead to additional energy cost advantages to the SECURE plant

  9. Low Temperature District Heating for Future Energy Systems

    DEFF Research Database (Denmark)

    Schmidt, Dietrich; Kallert, Anna; Blesl, Markus

    2017-01-01

    of the building stock. Low temperature district heating (LTDH) can contribute significantly to a more efficient use of energy resources as well as better integration of renewable energy (e.g. geothermal or solar heat), and surplus heat (e.g. industrial waste heat) into the heating sector. LTDH offers prospects......The building sector is responsible for more than one third of the final energy consumption of societies and produces the largest amount of greenhouse gas emissions of all sectors. This is due to the utilisation of combustion processes of mainly fossil fuels to satisfy the heating demand...... for both the demand side (community building structure) and the supply side (network properties or energy sources). Especially in connection with buildings that demand only low temperatures for space heating. The utilisation of lower temperatures reduces losses in pipelines and can increase the overall...

  10. Solar district heating and cooling: A review

    DEFF Research Database (Denmark)

    Perez-Mora, Nicolas; Bava, Federico; Andersen, Martin

    2018-01-01

    Both district heating and solar collector systems have been known and implemented for many years. However, the combination of the two, with solar collectors supplying heat to the district heating network, is relatively new, and no comprehensive review of scientific publications on this topic coul...

  11. Biomass universal district heating systems

    Science.gov (United States)

    Soltero, Victor Manuel; Rodríguez-Artacho, Salvador; Velázquez, Ramón; Chacartegui, Ricardo

    2017-11-01

    In mild climate regions Directive 27/2012 EU application for developing sustainable district heating networks in consolidated urban nucleus is a challenge. In Spain most of the municipalities above 5,000 inhabitants have a reliable natural gas network and individual heating systems at homes. In this work a new heating network paradigm is proposed, the biomass universal heating network in rural areas. This model involves all the economic, legal and technical aspects and interactions between the different agents of the systems: provider company, individual and collective end-users and local and regional administration. The continental region in Spain has 588 municipalities with a population above 1,500 inhabitants close to forest biomass with renewable use. In many of these cases the regulation identifies the ownership of the forest resources use. The universal heating networks are a great opportunity for energy saving of 2,000 GWh, avoiding 2.7 million tons of CO2 emissions and with a global annual savings for end users of 61.8 million of euros. The presented model is easily extrapolated to other small municipalities in Europe. The real application of the model is presented for three municipalities in different locations of Spain where Universal Heating Networks are under development. The analysis show the interest of the integrated model for the three cases with different structural agents and relationships between them. The use of sustainable forest resources, extracted and managed by local companies, strengths circular economy in the region with a potential global economic impact above 200 M€.

  12. 4th Generation District Heating (4GDH)

    DEFF Research Database (Denmark)

    Lund, Henrik; Werner, Sven; Wiltshire, Robin

    2014-01-01

    This paper defines the concept of 4th Generation District Heating (4GDH) including the relations to District Cooling and the concepts of smart energy and smart thermal grids. The motive is to identify the future challenges of reaching a future renewable non-fossil heat supply as part...... of the implementation of overall sustainable energy systems. The basic assumption is that district heating and cooling has an important role to play in future sustainable energy systems – including 100 percent renewable energy systems – but the present generation of district heating and cooling technologies will have...

  13. Energy saving and emission reduction of China's urban district heating

    International Nuclear Information System (INIS)

    Chen, Xia; Wang, Li; Tong, Lige; Sun, Shufeng; Yue, Xianfang; Yin, Shaowu; Zheng, Lifang

    2013-01-01

    China's carbon dioxide (CO 2 ) emission ranks highest in the world. China is committed to reduce its CO 2 emission by 40% to 45% from the 2005 levels by 2020. To fulfill the target, China's CO 2 emission reduction must exceed 6995 million tons. Energy consumption and CO 2 emission of China's urban district heating (UDH) are increasing. The current policy implemented to improve UDH focuses on replacing coal with natural gas to reduce energy consumption and CO 2 emission to some extent. This paper proposes that heat pump heating (HPH) could serve as a replacement for UDH to help realize energy-saving and emission-reduction goals to a greater extent. The paper also analyzes the impact of this replacement on the heating and power generation sectors. The results show that replacing coal-based UDH with HPH decreases energy consumption and CO 2 emission by 43% in the heating sector. In the power generation sector, the efficiency of power generation at the valley electricity time increases by 0.512%, and the ratio of peak–valley difference decreases by 16.5%. The decreases in CO 2 emission from the heating and power generation sectors cumulatively account for 5.55% of China's total CO 2 emission reduction target in 2020. - Highlights: ► Replacing urban district heating with heat pump heating. ► Impact of heat pump heating on heating and power generation sectors. ► Potential of energy saving and emission reduction for heat pump heating. ► China should adjust current urban heating strategy

  14. Renewable heat: Waste heat, an emerging sector full of resources. An eco-district fed by the heat from a data center; Integrating objectives matching the ambitions, clear and on the long term; High-energy wastes in Brittany: Brest is securing its heat network with multiple energies

    International Nuclear Information System (INIS)

    Richard, Aude

    2017-01-01

    This file on renewable heat contains four articles which themes are: waste heat (from incineration plants or industrial sites) is an emerging sector full of resources, which benefits now of a financial subsidy from ADEME, the French organization for energy and environment; an example is given with Chamtor, a highly energy-consuming cereal transformer. The second article presents an urban eco-district in Paris that is fed by the heat issued by a data center. The third article (Integrating objectives matching the ambitions, clear and on the long term) presents some recommendations from the French Renewable Energy Association (SER) towards a better energy valorization of residual wastes. The fourth article presents two examples of energy valorization of wastes in Brittany, one with the valorization of high-energy solid wastes for supplying heat to a milk farm and greenhouses, the other one concerns the development of a heat network supplied by an incineration plant, with a mix of energy sources such as wastes, wood and gas, and a special juridical scheme

  15. Heat savings in buildings in a 100% renewable heat and power system in Denmark with different shares of district heating

    DEFF Research Database (Denmark)

    Zvingilaite, Erika; Balyk, Olexandr

    2014-01-01

    The paper examines implementation of heat saving measures in buildings in 2050, under the assumption that heat and power supply comes solely from renewable resources in Denmark.Balmorel – a linear optimisation model of heat and power sectors in Denmark is used for investigating economically viable...... levels of heat savings, which can be implemented by reducing heat transmission losses through building elements and by installing ventilation systems with heat recovery, in different future Danish heat and power system scenarios. Today almost 50% of heat demand in Denmark is covered by district heating....... A further expansion of district heating network in Denmark is assessed and penetration of heat savings is analysed in this context.If all heat saving measures, included in the model, are implemented, heat demand in Danish buildings in 2050 could be reduced by around 40%. Results show that it is cost...

  16. District heat: who is to pay

    Energy Technology Data Exchange (ETDEWEB)

    1981-05-01

    Away from petroleum, is the slogan used by all politicians. And the sellers of power energies keep repeating this and interpret it as they like. But none ofthose responsible tells the public with what to heat if not with petroleum. Those offering district heating consider themselves to have the biggest chances for the area after fuel oil. Although the costs of district heating are enormously high. The people should be suspicious if district heating projects are given new economical weight under the perspective of creating new places of employment.

  17. District Heating Systems Performance Analyses. Heat Energy Tariff

    Science.gov (United States)

    Ziemele, Jelena; Vigants, Girts; Vitolins, Valdis; Blumberga, Dagnija; Veidenbergs, Ivars

    2014-12-01

    The paper addresses an important element of the European energy sector: the evaluation of district heating (DH) system operations from the standpoint of increasing energy efficiency and increasing the use of renewable energy resources. This has been done by developing a new methodology for the evaluation of the heat tariff. The paper presents an algorithm of this methodology, which includes not only a data base and calculation equation systems, but also an integrated multi-criteria analysis module using MADM/MCDM (Multi-Attribute Decision Making / Multi-Criteria Decision Making) based on TOPSIS (Technique for Order Performance by Similarity to Ideal Solution). The results of the multi-criteria analysis are used to set the tariff benchmarks. The evaluation methodology has been tested for Latvian heat tariffs, and the obtained results show that only half of heating companies reach a benchmark value equal to 0.5 for the efficiency closeness to the ideal solution indicator. This means that the proposed evaluation methodology would not only allow companies to determine how they perform with regard to the proposed benchmark, but also to identify their need to restructure so that they may reach the level of a low-carbon business.

  18. District heating in Italy: Extent of use

    International Nuclear Information System (INIS)

    Sacchi, E.

    1992-01-01

    The Author surveys the trend that has been established over the last two decades in the use of district heating in Italy. Comparison with the European situation reveals that Italy is lagging behind. The reason for this the Author states is the Italian public's aversion to unknown risks involved in the utilization of innovative technologies associated with cogeneration/district heating (current preference is given to autonomous methane fuelled building space heating systems), and the current opinion of some misinformed public administrations that cogeneration/district heating plants are too costly. Citing the successful campaign by the natural gas industry to promote the public acceptance of methane as a safe, readily available and competitively priced energy source, he suggests that similar efforts be made to have the public also accept cogeneration (with methane fired gas turbines)/district heating as being safe and environmentally, as well as, economically beneficial

  19. Performance analysis of hybrid district heating system

    DEFF Research Database (Denmark)

    Mikulandric, Robert; Krajačić, Goran; Khavin, Gennadii

    2013-01-01

    more extensively used in district heating systems either separately or as a supplement to traditional fossil fuels in order to achieve national energy policy objectives. However, they are still facing problems such as high intermittences, high energy production costs and low load factors as well...... could reach up to 20% with utilisation of solar energy as supplement energy source in traditional fossil fuel based district heating systems. In this work, the performance of hybrid district energy system for a particular location will be analysed. For performance analysis, mathematical model......District heating system could contribute to more efficient heat generation through cogeneration power plants or waste heat utilization facilities and to increase of renewable energy sources share in total energy consumption. In the most developed EU countries, renewable energy sources have been...

  20. Future Services for District Heating Solutions in Residential Districts

    Directory of Open Access Journals (Sweden)

    Hannele Ahvenniemi

    2014-06-01

    Full Text Available The underlying assumption of this study is that in order to retain the competitiveness while reaching for the EU targets regarding low-energy construction, district heating companies need to develop new business and service models. How district heating companies could broaden their perspective and switch to a more service-oriented way of thinking is a key interest of our research. The used methods in our study are house builder interviews and a questionnaire. With the help of these methods we discussed the potential interest in heating related services acquiring a comprehensive understanding of the customer needs. The results indicate the importance of certain criteria when choosing the heating system in households: easiness, comfort and affordability seem to dominate the house builders’ preferences. Also environmental awareness seems to be for many an important factor when making a decision about the heating of the house. Altogether, based on the results of this study, we suggest that the prospects of district heating could benefit from highlighting certain aspects and strengths in the future. District heating companies need to increase flexibility, readiness to adopt new services, to invest in new marketing strategies and improving the communication skills.

  1. Innovation in the district heating. Process study in February 2012; Innovasjon i fjernvarme. Prossesstudie februar 201

    Energy Technology Data Exchange (ETDEWEB)

    Hoey, Mads Bruun

    2012-07-01

    This process study shows that, in order to create more innovation for growth in the district heating sector, it requires a new initiative, carried out by the district heating companies themselves, in the areas described in the study. This is regarded as the opportunities that the program should look for and will be more complete by the descriptions of the workshop results. (eb)

  2. Toward 4th generation district heating

    DEFF Research Database (Denmark)

    Li, Hongwei; Svendsen, Svend; Dalla Rosa, Alessandro

    2014-01-01

    In many countries, district heating (DH) has a key role in the national strategic energy planning. However, tighter legislation on new and future buildings requires much less heating demand which subsequently causes relative high network heat loss. This will make current DH system uneconomical...... comparing with other local heat generation units. The design and operation of DH systems therefore needs to be re-examined, part of the solution being low operational temperature. The 3-years IEA DHC Annex X project ‘Towards 4th Generation District Heating: Experience and Potential of Low......-Temperature District Heating (LTDH)’ aims to document experiences gained in mature DH countries with low temperature systems serving highly energyefficient new buildings and existing buildings. The potential to supply DHW at temperature close to 50oC without the risk of Legionella was investigated. Information...

  3. 1992 National census for district heating, cooling and cogeneration

    Energy Technology Data Exchange (ETDEWEB)

    1993-07-01

    District energy systems are a major part of the energy use and delivery infrastructure of the United States. With nearly 6,000 operating systems currently in place, district energy represents approximately 800 billion BTU per hour of installed thermal production capacity, and provides over 1.1 quadrillion BTU of energy annually -- about 1.3% of all energy used in the US each year. Delivered through more that 20,000 miles of pipe, this energy is used to heat and cool almost 12 billion square feet of enclosed space in buildings that serve a diverse range of office, education, health care, military, industrial and residential needs. This Census is intended to provide a better understanding of the character and extent of district heating, cooling and cogeneration in the United States. It defines a district energy system as: Any system that provides thermal energy (steam, hot water, or chilled water) for space heating, space cooling, or process uses from a central plant, and that distributes the energy to two or more buildings through a network of pipes. If electricity is produced, the system is a cogenerating facility. The Census was conducted through surveys administered to the memberships of eleven national associations and agencies that collectively represent the great majority of the nation`s district energy system operators. Responses received from these surveys account for about 11% of all district systems in the United States. Data in this report is organized and presented within six user sectors selected to illustrate the significance of district energy in institutional, community and utility settings. Projections estimate the full extent of district energy systems in each sector.

  4. Optimising corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.; Andersen, A.

    2002-01-01

    A three-year project - financially supported by the Nordic Industrial Fund - on monitoring of corrosion in district heating systems has been initiated with participation of researchers and industrial partners in Denmark, Finland, Iceland, Norway and Sweden. The primary objective of the project...... is to improve the quality control in district heating systems by corrosion monitoring. In Danish systems electrochemical impedance spectroscopy (EIS), linear polarisation resistance (LPR), high-sensitive electrical resistance (ER) technology, crevice corrosion probes, as well as weight loss coupons...

  5. Lithuanian heat sector: Today based on imported fossil fuel, tomorrow - On local biofuel and wastes

    Energy Technology Data Exchange (ETDEWEB)

    Janukonis, Andrius

    2010-09-15

    District heating sector is one of the most important energy sectors in Lithuania, operation of which is closely related to other energy sectors such as electricity, natural gas, oil products, renewable energy sources. Main priorities of Lithuanian energy policy based on the experience of the neighboring countries and directives of the European Union's environmental protection, security and reliability of energy supply and availability of district heating services to all users. It is necessary to use widely the biofuel in the DHS sector for the heat production, unused amounts of which are very big.

  6. Urban district heating using nuclear heat - a survey

    International Nuclear Information System (INIS)

    Beresovski, T.; Oliker, I.

    1979-01-01

    The use of heat from nuclear power plants is of great interest in connection with projected future expansions of large urban district heating systems. Oil price escalation and air pollution from increased burning of fossil fuels are substantial incentivers for the adoption of nuclear heat and power plants. The cost of the hot water piping system from the nuclear plant to the city is a major factor in determining the feasibility of using nuclear heat. To achieve reasonable costs, the heat load should be at least 1500 MW(th), transport temperatures 125-200 0 C and distances preferably 50 km or less. Heat may be extracted from the turbines of conventional power reactors. Alternatively, some special-purpose smaller reactors are under development which are specially suited to production of heat with little or no power coproduct. Many countries are conducting studies of future expansions of district heating systems to use nuclear heat. Several countries are developing technology suitable for this application. Actual experience with the use of nuclear heat for district heating is currently being gained only in the USSR, however. While district heating appears to be a desirable technology at a time of increasing fossil-fuel costs, the use of nuclear heat will require siting of nuclear plants within transmission radius of cities. The institutional barries toward use of nuclear heating will have to be overcome before the energy conservation potential of this approach can be realized on a significant scale. (author)

  7. Dual energy use systems: District heating survey

    Science.gov (United States)

    1980-07-01

    The current status of and problems facing district heating systems operated by electric utilities were identified. The technical and economic factors which can affect the present and future success of district heating systems in the United States were evaluated. A survey of 59 district heating electric utilities was conducted to determine the current status of the industry. Questions developed to obtain data on technical, economic, regulator, and marketing factors were included in the survey. Literature on district heating in the U.S. and abroad was collected from governments, industry and foreign sources and reviewed to aid in evaluating the current and future potential of the industry. Interviews were held with executives of 16 utilities that operate district heating systems in order to determine corporate attitudes. A summary of the literature obtained is provided. Survey results are tabulated and described. The interviews and survey data were used to compile 10 case studies of utilities operating district heating systems under a braod range of circumstances.

  8. Leading sector development in Muaro Jambi District

    Directory of Open Access Journals (Sweden)

    Muhammad Safri

    2017-09-01

    Full Text Available Efforts to improve economic development and economic growth of Muaro Jambi Regency is a must. Efforts to increase economic development and economic growth can occur, if local governments are able to determine or identify priority sectors or become a base sector. Given the importance of determining and defining the right and correct strategy in the development of leading economic sectors/bases, it is necessary to conduct further study related to the development of leading sector policy in Muaro Jambi Regency. Analysis tools that are used are LQ (Location Quotient and SWOT analysis. The results of the analysis found that of there are three sectors that are the main sector or base in Muaro Jambi Regency, namely agriculture, livestock, plantation, fishery and forestry sector, mining and quarrying sector and manufacturing industry sector. Strategies that can be done in order to maintain and develop the sector and sub-sectors/recommended base there are several alternative strategies that combine internal environmental conditions and external environment Muaro Jambi Regency is S - O (power against opportunities, S - T (power against threats W - O (weakness to opportunity and W - T (weakness to threat. Keywords: Location Quotient, SWOT Analysis, Base Sector

  9. District heating strategy model: community manual

    Energy Technology Data Exchange (ETDEWEB)

    Hrabak, R. A.; Kron, Jr., N. F.; Pferdehirt, W. P.

    1981-10-01

    The US Department of Housing and Urban Development (HUD) and the US Department of Energy (DOE) cosponsor a program aimed at increasing the number of district heating and cooling systems. Twenty-eight communities have received HUD cooperative agreements to aid in a national feasibility assessment of district heating and cooling systems. The HUD/DOE program includes technical assistance provided by Argonne National Laboratory and Oak Ridge National Laboratory. Part of this assistance is a computer program, called the district heating strategy model, that performs preliminary calculations to analyze potential district heating and cooling systems. The model uses information about a community's physical characteristics, current electricity-supply systems, and local economic conditions to calculate heat demands, heat supplies from existing power plants and a new boiler, system construction costs, basic financial forecasts, and changes in air-pollutant emissions resulting from installation of a district heating and cooling system. This report explains the operation of the district heating strategy model, provides simplified forms for organizing the input data required, and describes and illustrates the model's output data. The report is written for three groups of people: (1) those in the HUD/DOE-sponsored communities who will be collecting input data, and studying output data, to assess the potential for district heating and cooling applications in their communiites; (2) those in any other communities who may wish to use the model for the same purpose; and (3) technical-support people assigned by the national laboratories to explain to community personnel how the model is used.

  10. Demand side management for smart district heating

    DEFF Research Database (Denmark)

    Big, Oovidiu; Li, Hongwei; Svendsen, Svend

    2016-01-01

    between 25% and 35%. By making the light renovation, the heating system needs a minimum supply water temperature of 58ºC in order to cover the thermal comfort. Through extensive renovation, the supply water temperature could be reduced to 50ºC which makes it possible to transform the District Heating...

  11. Proposal for a district heat supply system

    International Nuclear Information System (INIS)

    Alefeld, G.

    1976-01-01

    A district heating scheme is proposed which makes it possible to use the waste heat from power stations for the supply of households and industry. The heat is stored by evaporation of ammonia salts or liquids with dissolved salts. Both substances are transported on existing rail- or waterways to heating stations near the consumers, and the heat recovered by reaction of the two components. Then the product of reaction is transported back to the power stations, and reactivated by heat again. Based on a cost estimation, it can be shown that the proposed heat transport with heat trains or ships, at distances up to 100 km, results in heat costs which are to-day already below that of heat from fuel oil. The investment required for the heat transport system is unusually low due to the use of transport ways which already exist. The district heating system is not only favourable in respect of the environment, but actually reduces its present strain, both at the consumer and at the power stations. The technical advantages of the suggested concept, especially the possibility of introducing it in stages, are discussed. The consequences for the national economy regarding the safety of supply and the trade balance, as well as for the public transport undertakings, are obvious, and therefore not included in the paper. (orig.) [de

  12. District heating and heat storage using the solution heat of an ammonia/water system

    International Nuclear Information System (INIS)

    Taube, M.; Peier, W.; Mayor, J.C.

    1976-01-01

    The article describes a model for the optimum use of the heat energy generated in a nuclear power station for district heating and heat storage taking account of the electricity and heat demand varying with time. (HR/AK) [de

  13. Shortage of energy increases profitability of district heating

    International Nuclear Information System (INIS)

    2003-01-01

    Increased demand will cause the price of district heating to increase, but not to the level of the price of electricity. The cheapest heating alternative in Denmark, Norway and Sweden is district heating. In Norway, district heating is developed primarily for commercial buildings and housing cooperatives. Thirty per cent of all buildings under construction are prepared for district heating and the percentage will increase strongly in the coming time. The total net production of district heating in Norway in 2001 was 2000 GWh, which is only a small part of the total potential for district heating

  14. Industrial Heat Pump for a High Temperature District Heating Application

    DEFF Research Database (Denmark)

    Poulsen, Claus Nørgaard

    Domestic heat pumps for shallow geothermal heating of family houses are popular and the range and supply of standard solutions is large. However, in applications for large capacities and temperatures, like district heating in the mega Watt range, standard solutions for high temperatures are scarce...... and usually not suitable off-the-shelf, which demands customized industrial heat pumps to be designed to fit the specific application. At the Brædstrup CHP plant in Denmark, a pilot project deployed in 2012, is being tested involving a seasonal thermal energy storage system in underground boreholes, charged...... by excess thermal energy from thermal solar panels. An industrial heat pump system using the natural refrigerant ammonia, is extracting the thermal energy from the storage when needed, and produce hot water at 85°C, for the district heating grid. The heat pump also acts as contributor to electricity grid...

  15. Corrosion Fatigue in District Heating Water Tanks

    DEFF Research Database (Denmark)

    Maahn, Ernst Emanuel

    1996-01-01

    Three candidate materials for construction of buffer tanks for district heating water have been tested for corrosion fatigue properties in a district heating water environment. The investigation included Slow Strain Rate Testing of plain tensile specimens, crack initiation testing by corrosion...... fatigue of plain tensile specimens and crack growth rate determination for Compact Tensile Specimens under corrosion fatigue conditions. The three materials are equal with respect to stress corrosion sensibility and crack initiation. Crack growth rate is increased with a factor of 4-6 relative to an inert...

  16. A nuclear reactor for district heating

    International Nuclear Information System (INIS)

    Bancroft, A.R.; Fenton, N.

    1989-07-01

    Global energy requirements are expected to double over the next 40 years. In the northern hemisphere, many countries consume in excess of 25 percent of their primary energy supply for building heating. Satisfying this need, within the constraints now being acknowledged for sustainable global development, provides an important opportunity for district heating. Fuel-use flexibility, energy and resource conservation, and reduced atmospheric pollution from acid gases and greenhouse gases, are important features offered by district heating systems. Among the major fuel options, only hydro-electricity and nuclear heat completely avoid emissions of combustion gases. To fill the need for an economical nuclear heat source, Atomic Energy of Canada Limited has designed a 10 MW plant that is suitable as a heat source within a network or as the main supply to large individual users. Producing hot water at temperatures below 100 degrees C, it incorporates a small pool-type reactor based on AECL's successful SLOWPOKE Research Reactor. A 2 MW prototype for the commercial unit is now being tested at the Whiteshell Nuclear Research Establishment in Manitoba. With capital costs of $7 million (Canadian), unit energy costs are projected to be $0.02/kWh for a 10 MW unit operating in a heating grid over a 30-year period. By keeping the reactor power low and the water temperature below 100 degrees C, much of the complexity of the large nuclear power plants can be avoided, thus allowing these small, safe nuclear heating systems to be economically viable

  17. Fuzzy comprehensive evaluation of district heating systems

    International Nuclear Information System (INIS)

    Wei Bing; Wang Songling; Li Li

    2010-01-01

    Selecting the optimal type of district heating (DH) system is of great importance because different heating systems have different levels of efficiency, which will impact the system economics, environment and energy use. In this study, seven DH systems were analysed and evaluated by the fuzzy comprehensive evaluation method. The dimensionless number-goodness was introduced into the calculation, the economics, environment and energy technology factors were considered synthetically, and the final goodness values were obtained. The results show that if only one of the economics, environment or energy technology factors are considered, different heating systems have different goodness values. When all three factors were taken into account, the final ranking of goodness values was: combined heating and power>gas-fired boiler>water-source heat pump>coal-fired boiler>ground-source heat pump>solar-energy heat pump>oil-fired boiler. The combined heating and power system is the best choice from all seven systems; the gas-fired boiler system is the best of the three boiler systems for heating purpose; and the water-source heat pump is the best of the three heat pump systems for heating and cooling.

  18. THERMOS, district central heating nuclear reactors

    International Nuclear Information System (INIS)

    Patarin, L.

    1981-02-01

    In order to expand the penetration of uranium in the national energy balance sheet, the C.E.A. has been studying nuclear reactors for several years now, that are capable of providing heat at favourable economic conditions. In this paper the THERMOS model is introduced. After showing the attraction of direct town heating by nuclear energy, the author describes the THERMOS project, defines the potential market, notably in France, and applies the lay-out study to the Grenoble Nuclear Study Centre site with district communal heating in mind. The economic aspects of the scheme are briefly mentioned [fr

  19. Fault diagnosis methods for district heating substations

    Energy Technology Data Exchange (ETDEWEB)

    Pakanen, J.; Hyvaerinen, J.; Kuismin, J.; Ahonen, M. [VTT Building Technology, Espoo (Finland). Building Physics, Building Services and Fire Technology

    1996-12-31

    A district heating substation is a demanding process for fault diagnosis. The process is nonlinear, load conditions of the district heating network change unpredictably and standard instrumentation is designed only for control and local monitoring purposes, not for automated diagnosis. Extra instrumentation means additional cost, which is usually not acceptable to consumers. That is why all conventional methods are not applicable in this environment. The paper presents five different approaches to fault diagnosis. While developing the methods, various kinds of pragmatic aspects and robustness had to be considered in order to achieve practical solutions. The presented methods are: classification of faults using performance indexing, static and physical modelling of process equipment, energy balance of the process, interactive fault tree reasoning and statistical tests. The methods are applied to a control valve, a heat excharger, a mud separating device and the whole process. The developed methods are verified in practice using simulation, simulation or field tests. (orig.) (25 refs.)

  20. Geothermal district heating system feasibility analysis, Thermopolis, Wyoming

    Energy Technology Data Exchange (ETDEWEB)

    Goering, S.W.; Garing, K.L.; Coury, G.; Mickley, M.C.

    1982-04-26

    The purpose of this study is to determine the technical and economic feasibility of constructing and operating a district heating system to serve the residential, commercial, and public sectors in Thermopolis. The project geothermal resource assessment, based on reviews of existing information and data, indicated that substantial hot water resources likely exist in the Rose Dome region 10 miles northeast of Thermopolis, and with quantities capable of supporting the proposed geothermal uses. Preliminary engineering designs were developed to serve the space heating and hot water heating demands for buildings in the Thermopolis-East Thermopolis town service area. The heating district design is based on indirect geothermal heat supply and includes production wells, transmission lines, heat exchanger units, and the closed loop distribution and collection system necessary to serve the individual customers. Three options are presented for disposal of the cooled waters-reinjection, river disposal, and agricultural reuse. The preliminary engineering effort indicates the proposed system is technically feasible. The design is sized to serve 1545 residences, 190 businesses, and 24 public buildings. The peak design meets a demand of 128.2 million Btu at production rates of 6400 gpm.

  1. Design of biomass district heating systems

    International Nuclear Information System (INIS)

    Vallios, Ioannis; Tsoutsos, Theocharis; Papadakis, George

    2009-01-01

    The biomass exploitation takes advantage of the agricultural, forest, and manure residues and in extent, urban and industrial wastes, which under controlled burning conditions, can generate heat and electricity, with limited environmental impacts. Biomass can - significantly - contribute in the energy supplying system, if the engineers will adopt the necessary design changes to the traditional systems and become more familiar with the design details of the biomass heating systems. The aim of this paper is to present a methodology of the design of biomass district heating systems taking into consideration the optimum design of building structure and urban settlement around the plant. The essential energy parameters are presented for the size calculations of a biomass burning-district heating system, as well as for the environmental (i.e. Greenhouse Gas Emissions) and economic evaluation (i.e. selectivity and viability of the relevant investment). Emphasis has been placed upon the technical parameters of the biomass system, the economic details of the boiler, the heating distribution network, the heat exchanger and the Greenhouse Gas Emissions

  2. Design of biomass district heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Vallios, Ioannis [Energy Applications Mgr., METRON Ltd Engineering Company (Greece); Tsoutsos, Theocharis [Department of Environmental Engineering, Technical University of Crete, GR-73100 Chania (Greece); Papadakis, George [Department of Natural Resources and Agricultural Engineering, Agricultural University of Athens (Greece)

    2009-04-15

    The biomass exploitation takes advantage of the agricultural, forest, and manure residues and in extent, urban and industrial wastes, which under controlled burning conditions, can generate heat and electricity, with limited environmental impacts. Biomass can - significantly - contribute in the energy supplying system, if the engineers will adopt the necessary design changes to the traditional systems and become more familiar with the design details of the biomass heating systems. The aim of this paper is to present a methodology of the design of biomass district heating systems taking into consideration the optimum design of building structure and urban settlement around the plant. The essential energy parameters are presented for the size calculations of a biomass burning-district heating system, as well as for the environmental (i.e. Greenhouse Gas Emissions) and economic evaluation (i.e. selectivity and viability of the relevant investment). Emphasis has been placed upon the technical parameters of the biomass system, the economic details of the boiler, the heating distribution network, the heat exchanger and the Greenhouse Gas Emissions. (author)

  3. Space heating with ultra-low-temperature district heating - A case study of four single-family houses from the 1980s

    DEFF Research Database (Denmark)

    Østergaard, Dorte Skaarup; Svendsen, Svend

    District heating is predicted to play a large role in the future fossil free energy system. Apart from providing energy savings by utilizing surplus heat, the district heating system also provides flexibility to fluctuating electricity generation by bridging the electricity and the heating sector...... the four houses were modelled in the building simulation tool IDA ICE. The simulation models included the actual radiator sizes and the models were used to simulate the expected thermal comfort in the houses and resulting district heating return temperatures. Secondly measurements of the actual district...

  4. Corrosion Rate Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Nielsen, Lars Vendelbo; Andersen, A.

    2005-01-01

    Quality control in district heating systems to keep uniform corrosion rates low and localized corrosion minimal is based on water quality control. Side-stream units equipped with carbon steel probes for online monitoring were mounted in district heating plants to investigate which techniques would...... be applicable, and if on-line monitoring could improve the quality control. Water quality monitoring was applied as well as corrosion rate monitoring with linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS), electrical resistance (ER) technique, mass loss and a crevice corrosion...... cell for localized corrosion risk estimation. Important variations in corrosion rate due to changes in make-up water quality were detected with the continuous monitoring provided by ER and crevice cell, while LPR gave unreliable corrosion rates. The acquisition time of two-three days for EIS...

  5. Nuclear heat for industrial purposes and district heating

    International Nuclear Information System (INIS)

    1974-01-01

    Studies on the various possibilities for the application of heat from nuclear reactors in the form of district heat or process steam for industrial purposes had been made long before the present energy crisis. Although these studies have indicated technical feasibility and economical justification of such utilization, the availability of relatively cheap oil and difficulties in locating a nuclear heat source inside industrial areas did not stimulate much further development. Since the increase of oil prices, the interest in nuclear heat application is reawakened, and a number of new potential areas have been identified. It now seems generally recognized that the heat from nuclear reactors should play an important role in primary energy supply, not only for electricity production but also as direct heat. At present three broad areas of nuclear heat application are identified: Direct heat utilization in industrial processing requiring a temperature above 800 deg. C; Process steam utilization in various industries, requiring a temperature mainly in the range of 200-300 deg. C; Low temperature and waste heat utilization from nuclear power plants for desalination of sea water and district heating. Such classification is mainly related to the type and characteristics of the heat source or nuclear reactor which could be used for a particular application. Modified high temperature reactor types (HTR) are the candidates for direct heat application, while the LWR reactors can satisfy most of the demands for process steam. Production of waste heat is a characteristic of all thermal power plants, and its utilization is a major challenge in the field of power production

  6. Procedures for selecting and buying district heating equipment. Sofia district heating. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-11-01

    The aim of this Final Report, prepared for the project `Procedures for Selecting and Buying DistRict Heating Equipment - Sofia District Heating Company`, is to establish an overview of the activities accomplished, the outputs delivered and the general experience gained as a result of the project. The main objective of the project is to enable Sofia District Heating Company to prepare specifications and tender documents, identify possible suppliers, evaluate offers, etc. in connection with purchase of district heating equipment. This objective has been reached by using rehabilitation of sub-stations as an example requested by Sofia DH. The project was originally planned to be finalized end of 1995, but due to the extensions of the scope of work, the project has been prolonged until end 1997. The following main activities were accomplished: Preparation of a detailed work plan; Collection of background information; Discussion and advice about technical specifications and tender documents for sub-station rehabilitation; Input to terms of reference for a master plan study; Input to technical specification for heat meters; Collection of ideas for topics and examples related to dissemination of information to consumers about matters related to district heating consumption. (EG)

  7. Alternative institutional vehicles for geothermal district heating

    Energy Technology Data Exchange (ETDEWEB)

    Bressler, S.; Gardner, T.C.; King, D.; Nimmons, J.T.

    1980-06-01

    The attributes of various institutional entities which might participate in various phases of geothermal heating applications are described. Public entities considered include cities, counties, and special districts. Private entities discussed include cooperative organizations and non-member-owned private enterprises. The powers, authority and manner of operation of each of the institutional entities are reviewed. Some of the public utility regulatory implications which may affect choices among available alternatives are considered. (MHR)

  8. Slowpoke - its application to district heating

    International Nuclear Information System (INIS)

    Lynch, G.F.

    1987-07-01

    Over 25% of the primary energy consumption in most of the countries of the northern Pacific Basin is used to heat buildings. This represents an important opportunity for nuclear energy to significantly reduce the dependence on fossil fuels in an end-use application that is readily amenable to substitution. In a major departure from traditional nuclear power technology, Atomic Energy of Canada Limited has developed the SLOWPOKE Energy System - a 10 MWt nuclear heat source specially designed to satisfy the needs of local heating systems used by buildings and institutions. A prototype reactor has been constructed to verify in a very demonstrative way that the technical, economic and safety criteria for nuclear district heating systems can in fact be met

  9. SLOWPOKE-its application to district heating

    International Nuclear Information System (INIS)

    Lynch, G.F.

    1987-01-01

    Over 25% of the primary energy consumption in most of the countries of the northern Pacific Basin is used to heat buildings. This represents an important opportunity for nuclear energy to significantly reduce the dependence on fossil fuels in an end-use application that is readily amenable to substitution. In a major departure from traditional nuclear power technology, Atomic Energy of Canada Limited has developed the SLOWPOKE Energy System-a 10 MWt nuclear heat source specially designed to satisfy the needs of local heating systems used by buildings andinstitutions. A prototype reactor has been constructed to verify in a very demonstrative way that the technical, economic and safety criteria for nuclear district heating systems can in fact be met. (author)

  10. Innovative system for delivery of low temperature district heating

    OpenAIRE

    Ianakiev, A; Cui, JM; Garbett, S; Filer, A

    2017-01-01

    An innovative low temperature district heating (LTDH) local network is developed in Nottingham, supported by the REMOURBAN project, part of the H2020 Smart City and Community Lighthouse scheme. It was proposed that a branch emanating from the return pipe of the existing district heating system in Nottingham would be created to use low temperature heating for the first time on such scale in the UK. The development is aimed to extract unused heat from existing district heating system and to mak...

  11. Design of serially connected district heating heat pumps utilising a geothermal heat source

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2017-01-01

    The design of two heat pumps (HP), connected in series, was investigated for operation in the district heating (DH) network of the Greater Copenhagen area, Denmark. The installation was dimensioned to supply 7.2 MW of heat at a temperature of 85 °C. The heat pumps utilise a geothermal heat source...

  12. Application of Predictive Control in District Heating Systems

    DEFF Research Database (Denmark)

    Palsson, Olafur Petur; Madsen, Henrik; Søgaard, Henning Tangen

    1993-01-01

    In district heating systems, and in particular if the heat production cakes place at a combined heat and power (CHP) plant, a reasonable control strategy is to keep the supply temperature from the district heating plant as low as possible. However, the control is subject to some restrictions...

  13. Mapping of potential heat sources for heat pumps for district heating in Denmark

    International Nuclear Information System (INIS)

    Lund, Rasmus; Persson, Urban

    2016-01-01

    The ambitious policy in Denmark on having a 100% renewable energy supply in 2050 requires radical changes to the energy systems to avoid an extensive and unsustainable use of biomass resources. Currently, wind power is being expanded and the increasing supply of electricity is slowly pushing the CHP (combined heat and power) plants out of operation, reducing the energy efficiency of the DH (district heating) supply. Here, large heat pumps for district heating is a frequently mentioned solution as a flexible demand for electricity and an energy efficient heat producer. The idea is to make heat pump use a low temperature waste or ambient heat source, but it has so far been very unclear which heat sources are actually available for this purpose. In this study eight categories of heat sources are analysed for the case of Denmark and included in a detailed spatial analysis where the identified heat sources are put in relation to the district heating areas and the corresponding demands. The analysis shows that potential heat sources are present near almost all district heating areas and that sea water most likely will have to play a substantial role as a heat source in future energy systems in Denmark. - Highlights: • The availability of heat sources for heat pumps in Denmark are mapped and quantified. • A novel methodology for assessment of low temperature industrial excess heat is presented. • There are heat sources available for 99% of district heating networks in Denmark. • The concentration of heat sources is generally bigger around bigger cities than smaller. • Ambient temperature heat sources will be more needed in district heating of big cities.

  14. District heating - description of its current status and research issues; Fjaerrvaermens omvaerld - beskrivning av kunskaps- och forskningslaege

    Energy Technology Data Exchange (ETDEWEB)

    Werner, Sven; Skoeldberg, Haakan

    2007-07-01

    FVB Sweden and Profu have compiled the current knowledge and possible research issues for the Framework Council of the Swedish District Heating Association concerning major prevailing conditions from the fundamental idea of district heating, the benefits of district heating, and institutional conditions. A short survey of international district heating research is also given. With support from this compilation, the following 9 long term research issues and 5 short term issues for analysis are recommended for further work: Long term research issues: What principles, market values and definition are valid for surplus heat from the energy system? How will the future market for biomass fuels develop in Northern Europe? What are the future heat demands in the Swedish buildings? What are the optimal district heat price with respect to price elasticity, CHP, waste incineration, and industrial surplus heat? What are the overall risks with district heating and how shall these risks be assessed? How shall the energy efficiency for district heating systems be expressed in a simply way? How can the severe electricity dependency be reduced in district heating systems? Consequences and mitigation of really large accidents in district heating systems? What are the combined effects from all energy EC-directives for the Swedish district heating sector? Short term issues for analysis: Elimination of reduction of CHP operation at cold weather? Possible ways of increasing the power-to-heat ratio in existing CHP plants? Which Swedish and international branch rules are used in district heating systems? What are the experiences about tax and market induced incentives from the Swedish district heating systems? What are available knowledge and expectations of third party access in district heating systems?

  15. Steps towards modern trends in district heating

    Directory of Open Access Journals (Sweden)

    Vasek Lubomir

    2017-01-01

    Full Text Available This paper focuses on new trends in district heating a cooling (DHC area and algorithms allowing incorporating new technologies and performing optimal control. Classical district heating usually means huge source (as heating plant and set of pipes which transfer heat energy through a medium, mostly water, across whole town and chilled water is returning back to the plant. Let’s imagine a modern city where buildings are consuming only a fraction of the energy contrary to what buildings required in the past. And especially during sunny or windy days, they have energy to spare. Around of such modern city is not only the one big heating plant, but perhaps solar and wind farms, waste incinerators, industrial companies with energy surpluses. Simply in this modern city are dozens, perhaps hundreds of small energy producers that share pipe network or at least part of it. In such a district energy system, production planning is more difficult. And not only production, modern houses with minimal heat loss and data connections also allow to plan consumption more effectively. The aim is to achieve the best solution evaluated by the objective function, usually determined by minimizing the production and distribution costs and providing meets the needs of energy consumers. The method presented in this paper is based on a simulation using the proposed holonic distributed model. This model also introduces the idea of general prosumers strategy, where all active elements within the modern DHC system are represented by prosumer objects. The prosumers are perceived as objects able to actively participate in the planning and realization of the production and consumption of energy. It is assumed that the general behaviour of the object in DHC is the same, no matter how they differ in size and design. Thus, all the objects are defined by two characteristics - the ability to produce and consume. The model based on this basic principle, of course, with the most

  16. New waste heat district heating system with combined heat and power based on absorption heat exchange cycle in China

    International Nuclear Information System (INIS)

    Sun Fangtian; Fu Lin; Zhang Shigang; Sun Jian

    2012-01-01

    A new waste heat district heating system with combined heat and power based on absorption heat exchange cycle (DHAC) was developed to increase the heating capacity of combined heat and power (CHP) through waste heat recovery, and enhance heat transmission capacity of the existing primary side district heating network through decreasing return water temperature by new type absorption heat exchanger (AHE). The DHAC system and a conventional district heating system based on CHP (CDH) were analyzed in terms of both thermodynamics and economics. Compared to CDH, the DHAC increased heating capacity by 31% and increased heat transmission capacity of the existing primary side district heating network by 75%. The results showed that the exergetic efficiency of DHAC was 10.41% higher and the product exergy monetary cost was 36.6¥/GJ less than a CHD. DHAC is an effective way to increase thermal utilization factor of CHP, and to reduce district heating cost. - Highlights: ► Absorption heat pumps are used to recover waste heat in CHP. ► Absorption heat exchanger can reduce exergy loss in the heat transfer process. ► New waste heat heating system (DHAC) can increase heating capacity of CHP by 31%. ► DHAC can enhance heat transmission capacity of the primary pipe network by 75%. ► DHAC system has the higher exergetic efficiency and the better economic benefit.

  17. Low Temperature District Heating for Future Energy Systems

    DEFF Research Database (Denmark)

    Ford, Rufus; Pietruschka, Dirk; Sipilä, Kari

    This report titled “Case studies and demonstrations” is the subtask D report of the IEA DHC|CHP Annex TS1 project “Low Temperature District Heating for Future Energy Systems” carried out between 2013 and 2016. The project was led by Fraunhofer Institute for Building Physics (IBP) with the other...... include examples on low temperature district heating systems, solar heating in a district heating system, heat pump based heat supply and energy storages for both peak load management and for seasonal heat storage. Some demonstrations have been implemented while others are at planning phase...

  18. Factors impacting district heating companies' decision to provide small house customers with heat

    Energy Technology Data Exchange (ETDEWEB)

    Lygnerud, Kristina [University of Gothenburg, School of Business, Economics and Law, Box 610, SE-405 30 Gothenburg (Sweden); Peltola-Ojala, Paeivi [University of Joensuu, Department of Business and Economics, Law and Economics, P.O. Box 30, FIN-80101 Joensuu (Finland)

    2010-01-15

    District heating companies' efficiency of providing district heating to small houses in Finland and Sweden is studied. The method used is Data Envelopment Analysis (DEA). The results indicate that Finnish companies, overall, are more efficient when offering district heat to small house customers. In Finland, price increases demand and impacts district heating company efficiency the most. The lower price level in Finland, compared to Sweden, might be a reflection of competition between different heating goods. In Sweden, network size and company size (large companies are more efficient in providing small houses with heat than small ones) drive the efficiency of small house district heating. (author)

  19. Local business models for district heat production; Kaukolaemmoen paikalliset liiketoimintamallit

    Energy Technology Data Exchange (ETDEWEB)

    Hakala, L.; Pesola, A.; Vanhanen, J.

    2012-12-15

    Local district heating business, outside large urban centers, is a profitable business in Finland, which can be practiced with several different business models. In addition to the traditional, local district heating business, local district heat production can be also based on franchising business model, on integrated service model or on different types of cooperation models, either between a local district heat producer and industrial site providing surplus heat or between a local district heat producer and a larger district heating company. Locally available wood energy is currently utilized effectively in the traditional district heating business model, in which a local entrepreneur produces heat to consumers in the local area. The franchising model is a more advanced version of the traditional district heating entrepreneurship. In this model, franchisor funds part of the investments, as well as offers centralized maintenance and fuel supply, for example. In the integrated service model, the local district heat producer offers also energy efficiency services and other value-added services, which are based on either the local district heat suppliers or his partner's expertise. In the cooperation model with industrial site, the local district heating business is based on the utilization of the surplus heat from the industrial site. In some cases, profitable operating model approach may be a district heating company outsourcing operations of one or more heating plants to a local entrepreneur. It can be concluded that all business models for district heat production (traditional district heat business model, franchising, integrated service model, cooperative model) discussed in this report can be profitable in Finnish conditions, as well for the local heat producer as for the municipality - and, above all, they produce cost-competitive heat for the end-user. All the models were seen as viable and interesting and having possibilities for expansion Finland

  20. Analysis of Cooling Capability in Polish District Heating Substations

    OpenAIRE

    Markowicz, Catarina

    2012-01-01

    For a district heating company it is of importance to have an efficient and well performing system. A central part in the work to lower temperature levels in district heating networks is to acknowledge and improve cooling capability in substations. The aim of this thesis is to analyse substations in Polish district heating systems in order to identify reasons of poor cooling and to present suggestions of implementable measures. Furthermore, the economical saving potential from an improved coo...

  1. Smart energy systems and 4th generation district heating

    DEFF Research Database (Denmark)

    Lund, Henrik; Mathiesen, Brian Vad

    2015-01-01

    District heating and cooling are here to stay, but the district heating technology has to change. It has to adjust to the requirements of a future smart energy development. Therefore, research is essential, but not only research in university laboratories. Demonstration projects and innovation an...... and collaboration between industry and universities are important, not only in terms of technical improvements, but also institutional and organizational aspects.......District heating and cooling are here to stay, but the district heating technology has to change. It has to adjust to the requirements of a future smart energy development. Therefore, research is essential, but not only research in university laboratories. Demonstration projects and innovation...

  2. Drought disaster vulnerability mapping of agricultural sector in Bringin District, Semarang Regency

    Science.gov (United States)

    Lestari, D. R.; Pigawati, B.

    2018-02-01

    Agriculture sector is a sector that is directly affected by drought. The phenomenon of drought disaster on agriculture sector has occurred in Semarang regency. One of districts in Semarang which is affected by drought is Bringin district. Bringin district is a productive agricultural area. However, the district experienced the most severe drought in 2015. The question research of this study is, “How is the spatial distribution of drought vulnerability on agriculture sector in Bringin district, Semarang regency?” The purpose of this study is to determine the spatial distribution of drought vulnerability on agriculture sector to village units in Bringin district. This study investigated drought vulnerability based on Intergovernmental Panel on Climate Change (IPCC) by analyzing exposure, sensitivity, and adaptive capacity through mapping process. This study used quantitative approach. There were formulation analysis, scoring analysis, and overlay analysis. Drought vulnerability on agriculture sector in Bringin district was divided into three categories: low, medium, and high.

  3. Energy and exergy analysis of low temperature district heating network

    International Nuclear Information System (INIS)

    Li, Hongwei; Svendsen, Svend

    2012-01-01

    Low temperature district heating with reduced network supply and return temperature provides better match of the low quality building heating demand and the low quality heating supply from waste heat or renewable energy. In this paper, a hypothetical low temperature district heating network is designed to supply heating for 30 low energy detached residential houses. The network operational supply/return temperature is set as 55 °C/25 °C, which is in line with a pilot project carried out in Denmark. Two types of in-house substations are analyzed to supply the consumer domestic hot water demand. The space heating demand is supplied through floor heating in the bathroom and low temperature radiators in the rest of rooms. The network thermal and hydraulic conditions are simulated under steady state. A district heating network design and simulation code is developed to incorporate the network optimization procedure and the network simultaneous factor. Through the simulation, the overall system energy and exergy efficiencies are calculated and the exergy losses for the major district heating system components are identified. Based on the results, suggestions are given to further reduce the system energy/exergy losses and increase the quality match between the consumer heating demand and the district heating supply. -- Highlights: ► Exergy and energy analysis for low and medium temperature district heating systems. ► Different district heating network dimensioning methods are analyzed. ► Major exergy losses are identified in the district heating network and the in-house substations. ► Advantages to apply low temperature district heating are highlighted through exergy analysis. ► The influence of thermal by-pass on system exergy/energy performance is analyzed.

  4. Nuclear district heating system with a high-temperature reactor

    International Nuclear Information System (INIS)

    Schroeder, G.; Barnert, H.; Wischnewski, R.

    1978-01-01

    From the demand viewpoint, the connection of an installed nuclear thermal capacity of 290 MJ/s for district heating purposes would be possible in the central Ruhr District by 1982-1983. The nuclear district heating system is made up of several subsystems, for instance, a smaller size high-temperature reactor [500 MW(thermal)] as a nuclear heat-and-power plant and an interconnected district heating system with a feed temperature of 453 K (180 0 C). The expenditure for additional investments, additional fuel costs, and costs for substitute power capacity are charged to the thermal energy generation costs of the nuclear heat-and-power plant. For the nuclear district heating system, the district heating costs to the consumer will vary over wide limits, depending on local conditions, between 7.8 and 12.2 $/GJ at the commissioning date in 1983, assuming that all subsystems have to be newly installed. These costs can be lower than district heating costs in a conventional district heating system with fossil-fired heating stations

  5. An optimization approach for district heating strategic network design

    NARCIS (Netherlands)

    Bordin, Chiara; Gordini, Angelo; Vigo, Daniele

    2016-01-01

    District heating systems provide the heat generated in a centralized location to a set of users for their residential and commercial heating requirements. Heat distribution is generally obtained by using hot water or steam flowing through a closed network of insulated pipes and heat exchange

  6. Pricing district heating by marginal cost

    International Nuclear Information System (INIS)

    Difs, Kristina; Trygg, Louise

    2009-01-01

    A vital measure for industries when redirecting the energy systems towards sustainability is conversion from electricity to district heating (DH). This conversion can be achieved for example, by replacing electrical heating with DH and compression cooling with heat-driven absorption cooling. Conversion to DH must, however, always be an economically attractive choice for an industry. In this paper the effects for industries and the local DH supplier are analysed when pricing DH by marginal cost in combination with industrial energy efficiency measures. Energy audits have shown that the analysed industries can reduce their annual electricity use by 30% and increase the use of DH by 56%. When marginal costs are applied as DH tariffs and the industrial energy efficiency measures are implemented, the industrial energy costs can be reduced by 17%. When implementing the industrial energy efficiency measures and also considering a utility investment in the local energy system, the local DH supplier has a potential to reduce the total energy system cost by 1.6 million EUR. Global carbon dioxide emissions can be reduced by 25,000 tonnes if the industrial energy efficiency measures are implemented and when coal-condensing power is assumed to be the marginal electricity source. (author)

  7. Integrated multiscale simulation of combined heat and power based district heating system

    International Nuclear Information System (INIS)

    Li, Peifeng; Nord, Natasa; Ertesvåg, Ivar Ståle; Ge, Zhihua; Yang, Zhiping; Yang, Yongping

    2015-01-01

    Highlights: • Simulation of power plant, district heating network and heat users in detail and integrated. • Coupled calculation and analysis of the heat and pressure losses of the district heating network. • District heating is not preferable for very low heat load due to relatively high heat loss. • Lower design supply temperatures of the district heating network give higher system efficiency. - Abstract: Many studies have been carried out separately on combined heat and power and district heating. However, little work has been done considering the heat source, the district heating network and the heat users simultaneously, especially when it comes to the heating system with large-scale combined heat and power plant. For the purpose of energy conservation, it is very important to know well the system performance of the integrated heating system from the very primary fuel input to the terminal heat users. This paper set up a model of 300 MW electric power rated air-cooled combined heat and power plant using Ebsilon software, which was validated according to the design data from the turbine manufacturer. Then, the model of heating network and heat users were developed based on the fundamental theories of fluid mechanics and heat transfer. Finally the combined heat and power based district heating system was obtained and the system performances within multiscale scope of the system were analyzed using the developed Ebsilon model. Topics with regard to the heat loss, the pressure drop, the pump power consumption and the supply temperatures of the district heating network were discussed. Besides, the operational issues of the integrated system were also researched. Several useful conclusions were drawn. It was found that a lower design primary supply temperature of the district heating network would give a higher seasonal energy efficiency of the integrated system throughout the whole heating season. Moreover, it was not always right to relate low design

  8. Performance Analysis of a Hybrid District Heating System

    DEFF Research Database (Denmark)

    Mikulandric, Robert; Krajačić, Goran; Duic, Neven

    2015-01-01

    , the performance of a hybrid district energy system for a small town in Croatia has been analysed. Mathematical model for process analysis and optimisation algorithm for optimal system configuration has been developed and described. The main goal of the system optimisation is to reduce heat production costs....... Several energy sources for heat production have been considered in 8 different simulation cases. Simulation results show that the heat production costs could be reduced with introduction of different energy systems into an existing district heating system. Renewable energy based district heating systems...... could contribute to heat production costs decrease in district heating systems up to 30% in comparison with highly efficient heat production technologies based on conventional fuels....

  9. Challenges in Smart Low-Temperature District Heating Development

    DEFF Research Database (Denmark)

    Li, Hongwei; Wang, Stephen Jia

    2014-01-01

    Previous research and development shows that low temperature district heating (LTDH) system is economic feasible for low energy buildings and buildings at sparse areas. Coupling with reduced network temperature and well-designed district heating (DH) networks, LTDH can reduce network heat loss...... by up to 75% comparing with the current medium temperature district heating system. Further system efficiency improvement can be achieved through a holistic approach which includes measures such as reduced system design margin, enhanced demand side management and improved operation of decentralized heat...

  10. Integration of Space Heating and Hot Water Supply in Low Temperature District Heating

    DEFF Research Database (Denmark)

    Elmegaard, Brian; Ommen, Torben Schmidt; Markussen, Michael

    2014-01-01

    District heating makes it possible to provide heat for many consumers in an efficient manner. In particular, district heating based on combined heat and power production is highly efficient. One disadvantage of district heating is that there is a significant heat loss from the pipes...... pipes, where the water is at the highest temperature. The heat loss may be lowered by decreasing the temperatures in the network for which reason low temperature networks are proposed as a low loss solution for future district heating. However, the heating demand of the consumers involve both domestic...... is required by the consumer. In the present paper we study conventional district heating at different temperature levels and compare the energy efficiency, the exergetic efficiency and annual heating cost to solutions that utilize electricity for supplementary heating of domestic hot water in low temperature...

  11. District heating and combined heat and power generation from biomass

    International Nuclear Information System (INIS)

    Veski, Rein

    1999-01-01

    An Altener programme seminar District Heating and Combined Heat and Power Generation from Biomass. Minitraining seminar and study tours and also Business forum, Exhibition and Short company presentations were held in Tallinn on March 21-23, 1999. The Seminar was organised by the VTT Energy, the Estonian Bioenergy Association and the Estonian Heat and Power Association in co-operation with the AFB-net. The Agricultural and Forestry Biomass Network (AFB-net) is part of the ALTENER programme. The Network aims at promoting and stimulating the implementation and commercial utilisation of energy from biomass and waste, through the initiation of business opportunities. This includes national and international co-operation and the exchange of the personnel. The Seminar was attended by consulting companies, scientists, municipal authorities and representatives of co-ordinating bodies engaged in renewable energy management as well as DH and CHP plant managers, equipment manufacturers and local energy planners from Finland, Estonia, Latvia, Lithuania, Sweden, Denmark, Belgium, Slovenia and Slovak Republic. At the Seminar minitraining issues were dealt with: the current situation and future trends in biomass DH in the Baltic Sea countries, and biomass DH and CHP in Eastern and Central Europe, planning and construction of biomass-based DH plants, biomass fuel procurement and handling technology, combustion technology, DH networks, financing of biomass projects and evaluating of projects, and case projects in Eastern and Central European countries. The following were presented: boilers with a capacity of 100 kW or more, stoker burners, wood and straw handling equipment, wood fuel harvesters, choppers, pelletisers, district heating pipelines and networks. (author)

  12. Book of abstracts: 3rd International Conference on Smart Energy Systems and 4th Generation District Heating

    DEFF Research Database (Denmark)

    everyone for your valuable contributions. The aim is to present and discuss scientific findings and industrial experiences related to the development of Smart Energy Systems and future 4th Generation District Heating Technologies and Systems (4GDH). This development is fundamental to the implementation....... The Smart Energy System concept is essential for 100% renewable energy systems to harvest storage synergies and exploit low-value heat sources. The most effective and least-cost solutions are to be found when the electricity sector is combined with the heating and cooling sectors and/or the transport sector....... Moreover, the combination of electricity and gas infrastructures may play an important role in the design of future renewable energy systems. In its research on low-temperature district heating, the Strategic Research Centre for 4th Generation District Heating Technologies and Systems enhances...

  13. Energy and exergy analysis of low temperature district heating network

    DEFF Research Database (Denmark)

    Li, Hongwei; Svendsen, Svend

    2012-01-01

    is designed to supply heating for 30 low energy detached residential houses. The network operational supply/return temperature is set as 55 °C/25 °C, which is in line with a pilot project carried out in Denmark. Two types of in-house substations are analyzed to supply the consumer domestic hot water demand......Low temperature district heating with reduced network supply and return temperature provides better match of the low quality building heating demand and the low quality heating supply from waste heat or renewable energy. In this paper, a hypothetical low temperature district heating network....... The space heating demand is supplied through floor heating in the bathroom and low temperature radiators in the rest of rooms. The network thermal and hydraulic conditions are simulated under steady state. A district heating network design and simulation code is developed to incorporate the network...

  14. Upscaling a district heating system based on biogas cogeneration and heat pumps

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Fink, J.; Smit, Gerardus Johannes Maria; de Wit, Jan B.

    2015-01-01

    The energy supply of the Meppel district Nieuwveense landen is based on biogas cogeneration, district heating, and ground source heat pumps. A centrally located combined heat and power engine (CHP) converts biogas from the municipal wastewater treatment facility into electricity for heat pumps and

  15. End use in the domestic sector of Uttara Kannada District

    Energy Technology Data Exchange (ETDEWEB)

    Ramachandra, T.V.; Subramanian, D.K.; Joshi, N.V.; Gunaga, S.V.; Harikantra, R.B. [Indian Institute of Science, Bangalore (India). Centre for Ecological Sciences

    2000-05-01

    End use efficiency experiments conducted in some households of Masur village (based on 4 days experiment) of Kumta Taluk show that there is scope for saving 27-42% of energy by switching to improved devices, which are designed to maximise combustion rate (of fuel, ensuring the presence of sufficient oxygen), radiant heat transfer (from fire to vessels, keeping them as close to fire as possible), convection (to pass maximum hot gas over vessels, reducing drafts), conduction (heat is concentrated near the vessels by using insulating material for the stove) and user satisfaction (with user friendly design). The thermal performances of improved stoves designed at our Institute (ASTRA) have also been studied in the field. Irrespective of type of fuel, community, etc., improved stoves show significant saving in fuel. By switching to energy efficient devices 450,548 to 700,853 tonnes of fuel wood can be saved per year in the district. (author)

  16. District heating rehabilitation project in Kaerdla on Hiiumaa, Estonia. Final report

    International Nuclear Information System (INIS)

    1998-03-01

    The main objective of the project has been to assist Kaerdla Municipality with the rehabilitation of their district heating system with Danish technology, and thereby support and make it possible for the Municipality of Kaerdla to develop the district heating sector in Kaerdla and thereby also to reduce emissions of harmful gases to the environment, as well as making a much more rational and energy efficient system. The project would further on demonstrate the use of pre-insulated pipes, which are fully sealed against penetration of water as well as demonstrate the use of compact units as substations including weather compensation control systems for regulation of heat and hot tap water supply for the district heating consumers. Besides the project gives significantly decreases in energy consumption's and in the pollution from the production of energy, the objective of the project was also to put great stress on providing technical assistance to Kaerdla DH company, in order to make them capable in operation and maintenance of the new district heating system, and also to train the local operational staff in operation of the complete district heating system. The project will have a high demonstration value towards other towns in Estonia with similar problems and configurations of their heating systems. (EG)

  17. Casing free district heating pipes; Mantelfria fjaerrvaermeroer

    Energy Technology Data Exchange (ETDEWEB)

    Saellberg, Sven-Erik; Nilsson, Stefan [Swedish National Testing and Research Inst., Goeteborg (Sweden)

    2005-07-01

    Previous studies have shown that polyurethane insulation (PUR foam) on district heating pipes acts as protection against water if it is of good quality, i.e. free from cracks, cavities and other defects. On the other hand water vapour easily diffuses through PUR foam. However this is not a problem as long as the steel pipe is warmer than the surface layer, since the high temperature will prevent the vapour from condensating. What will happen with the insulation of a casing free district heating pipe where the ground water level occasionally reaches above the pipe has not been studied in detail. The current project has studied to what extent moisture enters the PUR foam insulation of two approximately one meter long district heating pipes without casing which have been in the ground for four years. Occasionally, the ground-water has entirely covered the pipes. In addition, the foam has been studied with respect to damage from the surrounding backfill material. Test specimens were taken out of the casing free pipes and were analysed with respect to moisture content. Additional measurements were done with a moisture indicator, and the electric resistance between the steel pipes and the four surveillance wires in each pipe was measured. The results from the various measurement techniques were the compared. The results show that the PUR foam remains dry as long as the service pipe is hot if no defects, such as crack and cavities, are present. Close to the service pipe, the foam actually dries out over time. The moisture content of the middle layer remains more or less constant. Only the colder parts on the outside exhibit an increase in moisture content. It was also seen that defects may lead to water ingress with subsequent humidification of the foam. However, the damaged foam area is limited. This is not the case for a regular pipe with a vapour tight casing, where experience show that moisture tend to spread along the pipe. The pipes were buried in sand and no

  18. Exergy and Energy Analysis of Low Temperature District Heating Network

    DEFF Research Database (Denmark)

    Li, Hongwei; Svendsen, Svend

    Low temperature district heating (LTDH) with reduced network supply and return temperature provides better match of the low quality building thermal demand and the low quality waste heat supply. In this paper, an exemplary LTDH network was designed for 30 low energy demand residential houses, which...... is in line with a pilot project that is carrying out in Denmark with network supply/return temperature at 55oC/25 oC. The consumer domestic hot water (DHW) demand is supplied with a special designed district heating (DH) storage tank. The space heating (SH) demand is supplied with a low temperature radiator....... The network thermal and hydraulic conditions were simulated under steady state with an in-house district heating network design and simulation code. Through simulation, the overall system energetic and exergetic efficiencies were calculated and the exergy losses for the major district heating system...

  19. Integration of space heating and hot water supply in low temperature district heating

    DEFF Research Database (Denmark)

    Elmegaard, Brian; Ommen, Torben Schmidt; Markussen, Michael

    2016-01-01

    of the consumers involves both domestic hot water and space heating. Space heating may be provided at low temperature in low energy buildings. Domestic hot water, however, needs sufficient temperatures to avoid growth of legionella. If the network temperature is below the demand temperature, supplementary heating......District heating may supply many consumers efficiently, but the heat loss from the pipes to the ground is a challenge. The heat loss may be lowered by decreasing the network temperatures for which reason low temperature networks are proposed for future district heating. The heating demand...... is required by the consumer. We study conventional district heating at different temperatures and compare the energy and exergetic efficiency and annual heating cost to solutions that utilize electricity for supplementary heating of domestic hot water in low temperature district heating. This includes direct...

  20. Conversion of individual natural gas to district heating

    DEFF Research Database (Denmark)

    Möller, Bernd; Lund, Henrik

    2010-01-01

    energy production. The present paper describes a geographical study of the potential to expand district heating into areas supplied with natural gas. The study uses a highly detailed spatial database of the built environment, its current and potential future energy demand, its supply technologies and its....... The analyses suggest to expand district heating from present 46% to somewhere in between 50% and 70%. The most attractive potential is located around towns and cities. The study also suggests that CO2-emissions, fuel consumption and socioeconomic costs can be reduced by expanding district heating, while...... location relative to energy infrastructure. First, using a spatially explicit economic model, the study calculates the potentials and costs of connection to expanded district heating networks by supply technology. Then a comprehensive energy systems analysis is carried out to model how the new district...

  1. Improving the performance of district heating systems by utilization of local heat boosters

    DEFF Research Database (Denmark)

    Falcone, A.; Dominkovic, D. F.; Pedersen, A. S.

    LTDH grid as they will have the strategical role of connecting the heating system with the electrical energy coming from the intermittent and fluctuating renewable energy sources such as wind and solar power. In this paper a case study of district heating system is presented and analysed. The goal......-50°C with return temperatures of 20-30 °C. This kind of heating system has many advantages and among all of them, it allows utilization of the heat coming from low exergy heat sources, as well as to decrease the grid heat losses. Electrical energy driven heat sources are also integrated into the future......District Heating (DH) plays an important role into the Danish energy green transition towards the future sustainable energy systems. The new, 4 th generation district heating network, the so called Low Temperature District Heating (LTDH), tends to lower the supply temperature of the heat down to 40...

  2. Calculating the marginal costs of a district-heating utility

    International Nuclear Information System (INIS)

    Sjoedin, Joergen; Henning, Dag

    2004-01-01

    District heating plays an important role in the Swedish heat-market. At the same time, the price of district heating varies considerably among different district-heating utilities. A case study is performed here in which a Swedish utility is analysed using three different methods for calculating the marginal costs of heat supply: a manual spreadsheet method, an optimising linear-programming model, and a least-cost dispatch simulation model. Calculated marginal-costs, obtained with the three methods, turn out to be similar. The calculated marginal-costs are also compared to the actual heat tariff in use by the utility. Using prices based on marginal costs should be able to bring about an efficient resource-allocation. It is found that the fixed rate the utility uses today should be replaced by a time-of-use rate, which would give a more accurate signal for customers to change their heat consumptions. (Author)

  3. The role of district heating in future renewable energy systems

    DEFF Research Database (Denmark)

    Lund, Henrik; Möller, Bernd; Mathiesen, Brian Vad

    2010-01-01

    heating options, including district heating as well as individual heat pumps and micro CHPs (Combined Heat and Power). The study includes almost 25 per cent of the Danish building stock, namely those buildings which have individual gas or oil boilers today and could be substituted by district heating......Based on the case of Denmark, this paper analyses the role of district heating in future Renewable Energy Systems. At present, the share of renewable energy is coming close to 20 per cent. From such point of departure, the paper defines a scenario framework in which the Danish system is converted...... to 100 per cent Renewable Energy Sources (RES) in the year 2060 including reductions in space heating demands by 75 per cent. By use of a detailed energy system analysis of the complete national energy system, the consequences in relation to fuel demand, CO2 emissions and cost are calculated for various...

  4. Innovative system for delivery of low temperature district heating

    Directory of Open Access Journals (Sweden)

    Anton Ivanov Ianakiev

    2017-01-01

    Full Text Available An innovative Low Temperature District Heating (LTDH local network is developed in Nottingham, supported by REMOURBAN project, part of the H2020 Smart City and Community Lighthouse scheme. It was proposed that a branch emanating from the return pipe of the of the existing district heating system in Nottingham would be created to use low temperature heating for the first time in UK. The development is aimed to extract wasted (unused heat from existing district heating system and make it more efficient and profitable. Four maisonette blocks of 94 low-raised flats, at Nottingham demo site of the REMOURBAN project will be connected to this new LTDH system. The scheme will provide a primary supply of heat and hot water at approximately 50oC to 60oC. Innovated solutions have been put forward to overcome certain barriers, such as legionella related risks and peak loads during extreme heating seasons and occasional maintenance.

  5. Integration of large-scale heat pumps in the district heating systems of Greater Copenhagen

    DEFF Research Database (Denmark)

    Bach, Bjarne; Werling, Jesper; Ommen, Torben Schmidt

    2016-01-01

    This study analyses the technical and private economic aspects of integrating a large capacity of electric driven HP (heat pumps) in the Greater Copenhagen DH (district heating) system, which is an example of a state-of-the-art large district heating system with many consumers and suppliers...

  6. GIS based analysis of future district heating potential in Denmark

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Möller, Bernd

    2013-01-01

    The physical placement of buildings is important when determining the potential for DH (district heating). Good locations for DH are mainly determined by having both a large heat demand within a certain area and having access to local heat resources. In recent years, the locations of buildings...

  7. Combined generation of electric and heating energy in future development of Yugoslav energy sector until 2000

    International Nuclear Information System (INIS)

    Djajic, Nenad; Zivanovic, Vladimir

    2000-01-01

    Development of the district heating system in the FR Yugoslavia, beside the combined generation of electric and heating energy presents a necessity for energy, economic and ecological reasons. Although the structure of energy reserves is rather unfavourable considering that the lignite is being predominantly used, available reserves of energy raw material are able to ensure the long-term development of Yugoslav energy sector, and to offer real possibilities for considerable substitution of foreign good quality fuels, especially in district heating systems. Their further development will depend, among other things: on the implementation of new technological solutions for the exploitation of local energy resources; need of reconstruction, revitalisation and transformation of old condensing thermal power plants into the cogeneration plants; installation of remote controlled transmission of heating energy as well as on development of heating plants and smaller co-generation plants based on local energy resources. (Authors)

  8. District heating by the Bohunice nuclear power plant

    International Nuclear Information System (INIS)

    Metke, E.; Skvarka, P.

    1984-01-01

    Technical and economical aspects of district heating by the electricity generating nuclear plants in Czechoslovakia are discussed. As a first stage of the project, 240 MW thermal power will be supplied using bleeding lines steam from the B-2 nuclear power plant at Jaslovske Bohunice to heat up water at a central station to 130 grad C. The maximal thermal power that can be produced for district heating by WWER type reactors with regular condensation turbines is estimated to be: 465 MW for a WWER-440 reactor with two 220 MWe turbines and 950 MW for a WWER-1000 reactor with a Skoda made 1000 MWe turbine using a three-stage scheme to heat up water from 60 grad C to 150 grad C. The use of satelite heating turbines connected to the steam collector is expected to improve the efficiency. District heating needs will de taken into account for siting of the new power plants

  9. Benefits of Integrating Geographically Distributed District Heating Systems

    DEFF Research Database (Denmark)

    Dominkovic, Dominik Franjo; Bačeković, I.; Sveinbjörnsson, Dadi Þorsteinn

    2016-01-01

    was reduced by 1.76 %. For the year 2029, in which intermittent renewable energy sources are dominating the energy generation, total socio-economic costs were reduced by 5.9 %, CO2 emissions by 7.1 % and primary energy supply by 8.4 % after the adjacent district heating systems were connected. Hence......Although liberalization of the electricity day-ahead markets has gained pace throughout the Europe, district heating markets are often dominated by lack of competition between suppliers, which curbs the potential of having cheaper systems in terms of socio-economic costs, and technically better...... system in terms of CO2 emissions. In order to assess the financial and technical outcome of connecting five adjacent district heating systems, a linear continuous optimization model that minimizes total socio-economic costs was developed. Geographical distribution of different district heating systems...

  10. Design and safety aspects of nuclear district heating reactors

    International Nuclear Information System (INIS)

    Brogli, R.; Mathews, D.; Pelloni, S.

    1989-01-01

    Extensive studies on the rationale, the potential and the technology of nuclear district heating have been performed in Switzerland. Beside economics the safety aspects were of primary importance. Due to the high costs to transport heat the heating reactor tend to be small and therefore, minimally staffed and located close to population centers. Stringed safety rules are therefore applying. Gas cooled reactors are well suited as district heating reactors since they have due to their characteristics several inherent features, significant safety margins and a remarkable radioactivity retention potential. Some ways to mitigate the effects of water ingress and graphite corrosion are under investigation. (author). 5 refs, 3 figs

  11. Consumer Unit for Low Energy District Heating Net

    DEFF Research Database (Denmark)

    Paulsen, Otto; Fan, Jianhua; Furbo, Simon

    2008-01-01

    heat load on a daily basis, having a flow temperature control based on outdoor climate. The unit is designed for a near constant district heating water flow. The paper describes two concepts. The analyses are based on TRNSYS (Klein et al., 2006) simulation, supplied with laboratory verification...... to reduce heat loss in the network. The consumer’s installation is a unit type with an accumulation tank for smoothing the heat load related to the domestic hot water. The building heat load is delivered by an under-floor heating system. The heavy under-floor heating system is assumed to smooth the room...

  12. Design of A District Heating System Including The Upgrading of Residual Industrial Waste Heat

    NARCIS (Netherlands)

    Falcao, P.W.; Mesbah, A.; Suherman, M.V.; Wennekes, S.

    2005-01-01

    This study was aimed to evaluate the feasibility of using a waste heat stream from DSM for a District Heating System. A conceptual design was carried out with emphasis on the unit for upgrading the residual waste heat. Having reviewed heat pump technology, mechanical heat pump was found to be the

  13. Water pipe network as a heat source for heat pump integrated into a district heating

    Science.gov (United States)

    Jadwiszczak, Piotr; Niemierka, Elżbieta

    2017-11-01

    The paper will present a technical analysis of the performance of the Heat Pumps (HP) installed in the domestic water pipe network for a big city scale. The HP integration scheme predicts the domestic water flow as a heat source and the district heating as a heat sink. The technical factors which influence on the estimated thermal power and performance of HP unit will be identified. Additionally, the pros and cons of HP operation in water intake will be determined. The analysis will be based on long-term measurement data from Głogów city.

  14. Opportunities for District Heating Systems in Ukraine. Market survey. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Brienen, M.

    2011-12-15

    The market survey should identify the existing and future opportunities for Dutch companies in the district heating sector in Ukraine, facilitate better understanding of the sector specifics by providing a complete picture on the whole district heating chain at specific cities mentioned and surrounding areas, and provide practical information on the best ways to enter this market segment by Dutch companies. The points of special interest are: (a) Analysis of main types of district heating chain in terms of the key stakeholders and their interest; Identification of the cases where the whole chain is under control (if any); Identification of the main directions of change within the existing set-up; (b) Analysis of the pricing model(s) and the procedures for setting up the prices for district heating; Identification of the main influencers on the decision making; (c) Identification of the main opportunities to use renewable energy for heating systems in Ukraine; and (d) Identification of the Dutch clusters with appropriate products, services and knowledge which can be used to achieve optimal results with district heating systems in Ukraine. Another important reason to execute this market survey is the 2g at-sign thereprogramme 'Ukraine-sustainable energy'. One of the consortia supported under the 2g at-sign there programme, is called NUSEP, Netherlands Ukrainian Sustainable Energy Platform. Under this platform 15-20 Dutch companies and institutes have joined forces. All of these companies and institutes are active in the field of(sustainable) energy. In short, the district heating sector in Ukraine offers many opportunities for Dutch companies. This survey will help Dutch companies to do business in Ukraine. The market research has been executed at both national level (where relevant concerns) and is specifically focused on the following cities and surrounding area: Kiev; Poltava; Kamyanets-Podilsky; Kovel; Lviv; Zhytomyr. Since the major developments in

  15. Framework conditions for Nordic district heating - Similarities and differences, and why Norway sticks out

    DEFF Research Database (Denmark)

    Sandberg, Eli; Sneum, Daniel Møller; Trømborg, Erik

    2018-01-01

    is competitive, both in DH and individual heating in Norway. This study further suggests, by comparing the impacts and implications of differences in cost components in a model plant, that differences in profitability is currently small between the Nordic countries. However, historical and geographical factors......The district heating (DH) sectors differ considerably among the Nordic countries: DH is an important contributor to heat supply in Denmark, Finland and Sweden, but in Norway it plays only a minor role. In this study, we compare historical, economic, jurisdictional, political and geographical...

  16. Licensing fees in the district heating industry; Gestattungsentgelte in der Fernwaermewirtschaft

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Norman [Jena Univ. (Germany)

    2009-10-15

    By means of licensing agreements municipalities grant the right to the district heating suppliers to use their properties with or without fees for the construction of district heating pipelines. Contrary to the power industry or gas industry, this type of contract is not regulated by special legal and price-legal regulations. Often an uncertainty exists whether and in which amount the municipalities may require a return for the right of utilization. In particular, this is valid if municipalities make the extension of discontinued licensing agreements dependent on the agreement of higher license fees. The general review under consideration reports on any legal limits of the amount of the licence fees. At the same time, a reference to licence fees in the power sector and gas sector is performed. In addition, the author reports on the law historical and law political background of license fees.

  17. Economic potentials of CHP connected to district heat systems in Germany. Implementation of the EU Efficiency Directive

    International Nuclear Information System (INIS)

    Eikmeier, Bernd

    2015-01-01

    The EU Efficiency Directive (2012/27/EU) is requiring all member states to carry out an evaluation of the potential for highly efficient CHP and the efficient use of district heating and cooling by December 2015. The German Federal Ministry of Economic Affairs and Energy appointed this task to the Fraunhofer Institute for Manufacturing and Advanced Materials, division for Energy Systems Analysis (formerly Bremer Energie Institut) in conjunction with other partners. The results for the sector district- and communal heating with CHP, sub-sectors private households, trade and services industry, are presented in this article.

  18. Performance of ultra low temperature district heating systems with utility plant and booster heat pumps

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Thorsen, Jan Eric; Markussen, Wiebke Brix

    2017-01-01

    The optimal integration of booster heat pumps in ultra low temperature district heating (ULTDH) was investigated and compared to the performance of low temperature district heating. Two possible heat production technologies for the DH networks were analysed, namely extraction combined heat...... and power (CHP) and central heat pumps (HPs). The analysis focussed on the characteristic heat demands of newly build multi-story buildings and the results were based on the ratio of the individual demands compared to the total. It was found that the optimal return temperature was dependent on the forward...

  19. Load Prediction in District Heating Systems; Lastprognoser foer fjaerrvaerme

    Energy Technology Data Exchange (ETDEWEB)

    Kvarnstroem, Johan; Dotzauer, Erik; Gollvik, Lena; Andersson, Cari

    2007-12-15

    To produce heat and power is costly. Therefore it is important for the district heating companies to plan and optimize the production. The principal procedure is to first construct a prediction of the heat demand, and then, given the demand prediction, plan the production. Due to the complexity of the problem, the need for mathematical models is obvious. The common way to predict the heat demand is to use one single load curve for the whole district heating network. This has obvious drawbacks. With only one curve it is difficult to consider e.g. restrictions in distribution capacity and the dynamics in the network. The standard approach is also to base the predictions on delivered heat from the production plants. During the last few years it has become more common to measure the load directly at the consumer sites. This gives new opportunities for the construction of load predictions. Another type of information that is not exploited today is the fact that the consumption patterns differ for different categories of consumers. For example, the load profiles for a residential house and an office diverge. An alternative approach is then to consider this in the load prediction algorithm. The aim with current project is to investigate alternative methods for prediction of district heating demand. Focus is on how to exploit measurements from the consumer sites. Also the possibility to make predictions using physical models is discussed. Numerical results based on data from the district heating systems in Stockholm owned by Fortum are presented

  20. On-line corrosion monitoring in geothermal district heating systems

    DEFF Research Database (Denmark)

    Richter, S.; Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.

    2006-01-01

    General corrosion rates in the geothermal district heating systems in Iceland are generally low, of the magnitude 1 lm/y. The reason is high pH (9.5), low-conductivity (200 lm/y) and negligible dissolved oxygen. The geothermal hot water is either used directly from source or to heat up cold ground...

  1. GIS Based Analysis of future district heating potential in Denmark

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Möller, Bernd

    2012-01-01

    The physical placement of buildings is important when determining the future potential for district heating (DH). Good locations for DH are mainly determined by having a large heat demand within a certain area combined with an access to local resources. In Denmark, the placement of buildings...

  2. District Heating Network Design and Configuration Optimization with Genetic Algorithm

    DEFF Research Database (Denmark)

    Li, Hongwei; Svendsen, Svend

    2013-01-01

    and the pipe friction and heat loss formulations are non-linear. In order to find the optimal district heating network configuration, genetic algorithm which handles the mixed integer nonlinear programming problem is chosen. The network configuration is represented with binary and integer encoding...

  3. Feasibility Study on Solar District Heating in China

    DEFF Research Database (Denmark)

    Huang, Junpeng; Fan, Jianhua; Furbo, Simon

    This paper analyzes the feasibility of developing solar district heating (SDH) in China from the perspective of incentive policy, selections of technical route, regional adaptability and economic feasibility for clean heating. Based on the analyzation, this proposes a road map for the development...

  4. Market opening and third party access in district heating networks

    International Nuclear Information System (INIS)

    Soederholm, Patrik; Waarell, Linda

    2011-01-01

    The purpose of this paper is to analyse the possible effects of introducing TPA in district heating networks by identifying and scrutinizing a number of possible scenarios for increased competition. The analysis builds on a theoretical discussion of economic efficiency in district heating operations, and the possible impacts on consumer prices of a market opening. An important conclusion is that regulated TPA may have small positive effects on competition, and at the same time it can have a negative impact on the possibility to run the integrated district heating operations in a cost-effective manner. This conclusion stems in part from the observation that most district heating networks are local in scope. Moreover, district heating operations are highly interdependent in, for instance, that the level of the return temperature of the water will affect the efficiency of combined heat and power plants. For these reasons, the introduction of the so-called single-buyer model or, perhaps even more preferable, an extended and more transparent producer market could represent more efficient market designs. Moreover, in networks with clear natural monopoly characteristics an ex ante price regulation must be considered. (author)

  5. Energy source completion for geothermal district heating systems

    International Nuclear Information System (INIS)

    Popovski, Kiril

    2000-01-01

    Geothermal district heating systems differs from the others mainly in the part of energy source completion and its connection to the heat distribution systems rather known problem. Even rather known problematic in the countries where geothermal energy is in wide application, new appearances of mistakes are always present due to the fact that necessary literature is difficult to be found. Essentials of the geothermal well completion and connection of geothermal source to the district heating distribution system are summarized in the paper and several examples of geothermal projects in flow are presented. (Author)

  6. Dedicated low temperature nuclear district heating plants: Rationale and prospects

    International Nuclear Information System (INIS)

    Goetzmann, C.A.

    1997-01-01

    Space heating accounts for a substantial fraction of the end-energy consumption in a large number of industrialized countries. Accordingly, efforts have been under way since many years to utilize nuclear energy as a source for district heating. The paper describes the key technical and institutional issues affecting the implementation of such technology. It is argued that the basic case for nuclear district heating is sound but that its introduction merits and drawbacks strongly depend on local circumstances. (author). 4 figs, 1 tab

  7. District heating and co-generation in Slovenia

    International Nuclear Information System (INIS)

    Hrovatin, Franc; Pecaric, Marko; Perovic, Olgica

    2000-01-01

    Recent development of district heating systems, gasification and co-generation processes in local communities in Slovenia as well as current status, potentials, possibilities and plans for further development in this sphere are presented. The current status presents energy production, distribution and use in district heating systems and in local gas distribution networks. An analysis of the energy and power generated and distributed in district power systems, made with regard to the size of the system, fuel used, type of consumers and the way of production, is given. Growth in different areas of local power systems in the period of last years is included. Potentials in the sphere of electrical energy and heat co-generation were assessed. Some possibilities and experience in heat energy storage are given and trends and plans for further development are introduced. (Authors)

  8. District Heating in Areas with Low Energy Houses

    DEFF Research Database (Denmark)

    Tol, Hakan Ibrahim

    This PhD thesis presents a summary of a three-year PhD project involving three case studies, each pertaining to a typical regional Danish energy planning scheme with regard to the extensive use of low-energy district heating systems, operating at temperatures as low as 55°C for supply and 25°C......-energy houses involved, together with the idea of utilizing booster pumps in the district heating network and (ii) use of network layouts of either a branched (tree-like) or a looped type. The methods developed were applied in a case study, the data of which was provided by the municipality of Roskilde...... in Denmark. The second case study was aimed at solving another regional energy planning scheme, one concerned with already existing houses, the heat requirements of which were currently being met by use of a natural gas grid or a conventional high-temperature district heating network. The idea considered...

  9. Chances for nuclear district heat generation

    International Nuclear Information System (INIS)

    Winkens, H.P.

    1986-01-01

    Nuclear power plants in the FRG or other European countries so far have not been intended for heat generation, as for reasons of safety they have to be sited too far away from urban agglomerations to make heat transport competible. In addition, heat generation costs of fossil-fueled power plants have not been so much higher than those of nuclear power stations that the extra cost for heat transport over large distances could have been justified. This situation is expected to gradually change over the next decade, as the heat from fossil-fueled power stations will become more expensive, as a result of this heat capacity being more and more used for medium-load and peak-load supply only, and with more efficient heat distribution systems becoming available in the near future. (orig.) [de

  10. Energy efficiency improvements utilising mass flow control and a ring topology in a district heating network

    International Nuclear Information System (INIS)

    Laajalehto, Tatu; Kuosa, Maunu; Mäkilä, Tapio; Lampinen, Markku; Lahdelma, Risto

    2014-01-01

    Heating and cooling have a major role in the energy sector, covering 46% of total final energy use worldwide. District heating (DH) is a significant technology for improving the energy efficiency of heating systems in communities, because it enables waste heat sources to be utilised economically and therefore significantly reduces the environmental impacts of power generation. As a result of new and more stringent construction regulations for buildings, the heat demands of individual buildings are decreasing and more energy-efficient heating systems have to be developed. In this study, the energy efficiency of a new DH system which includes both a new control system called mass flow control and a new network design called a ring network is examined. A topology in the Helsinki region is studied by using a commercial DH network modelling tool, Grades Heating. The district heating network is attached to a wood-burning heat station which has a heat recovery system in use. Examination is performed by means of both technical and economic analysis. The new non-linear temperature programme that is required is adopted for supply and return temperatures, which allows greater temperature cooling and smaller flow rates. Lower district heating water temperatures are essential when reducing the heat losses in the network and heat production. Mass flow control allows smaller pressure drops in the network and thus reduces the pumping power. The aim of this study was to determine the most energy-efficient DH water supply temperatures in the case network. If the ring network design is utilised, the district heating system is easier to control. As a result the total heat consumption within the heating season is reduced compared to traditional DH systems. On the basis of the results, the new DH system is significantly more energy-efficient in the case network that was examined than the traditional design. For example, average energy losses within the constraints (which consist of heat

  11. District heating from coal cures Germany's oil phobia

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, G.

    1982-04-30

    Germany's firm commitment to district heating, energy conservation and renewable energy was the most striking impression to emerge from this year's Hanover Fair. Despite the present low price of oil, industry and government are resolved to reduce the country's dependence on this fuel. Although oil now accounts for only 44 per cent of German's total energy consumption, compared with 55 per cent in 1972, price rises and economic stagnation mean that its value is now equivalent to some 20 per cent of the country's exports compared with just 6 per cent in 1972. Space and process heating are the biggest oil users. District heating schemes, heat pumps and waste-heat recovery are all being vigorously promoted to reduce the oil demand from these sectors. A recent study by the German Ministry of Research and Technology estimates that 25 per cent of all domestic heat could be delivered economically by district heating, some three times the present installed capacity.

  12. Geothermal energy developments in the district heating of Szeged

    OpenAIRE

    Osvald, Máté; Szanyi, János; Medgyes, Tamás; Kóbor, Balázs; Csanádi, Attila

    2017-01-01

    The District Heating Company of Szeged supplies heat and domestic hot water to 27,000 households and 500 public buildings in Szeged. In 2015, the company decided to introduce geothermal sources into 4 of its 23 heating circuits and started the preparation activities of the development. Preliminary investigations revealed that injection into the sandstone reservoir and the hydraulic connection with already existing wells pose the greatest hydrogeological risks, while placement and operation of...

  13. Spatiotemporal and economic analysis of industrial excess heat as a resource for district heating

    DEFF Research Database (Denmark)

    Bühler, Fabian; Petrović, Stefan; Holm, Fridolin Müller

    2018-01-01

    detailed analysis of the most suitable types of industries and the costs is required, allowing a targeted exploitation of this resource. This work extends the spatial and thermodynamic analysis, to account for the temporal match between industrial excess heat and district heating demands, as well...... and lack of demand, reduces the theoretical substitution potential by almost 30%. If heat storages are introduced, the total potential is reduced by only 10%. A majority of the excess heat can be utilised at socio-economic heating costs lower than the average Danish district heating price and the cost...

  14. Exergetic evaluation of heat pump booster configurations in a low temperature district heating network

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Elmegaard, Brian

    2012-01-01

    In order to minimise losses in a district heating network, one approach is to lower the temperature difference between working media and soil. Considering only direct heat exchange, the minimum forward temperature level is determined by the demand side, as energy services are required at a certain...... temperature. As domestic hot water is required at a temperature range where legionella is no longer a threat, forward temperatures in a traditional low temperature district heating network cannot be lowered beyond approximately 55 ºC. One solution is to boost the temperature of the forward tap water stream...... with a heat pump, as the remaining heat demands are often not required at temperature levels as high as the tap water. The scope of this work is to evaluate the power consumption and second law efficiency of booster heat pumps for tap water production in a low temperature district heating network. The heat...

  15. Load Management in District Heating Operation

    DEFF Research Database (Denmark)

    Li, Hongwei; Wang, Stephen Jia

    2015-01-01

    heating load can be reduced through building demand side management. The building thermal mass can be used to shift the heating supply under the circumstance without jeopardizing the consumer thermal comfort. In this paper, the multi-agent framework is applied to a simplified building dynamic model...

  16. EXPLORING THE ROLE OF FORESTRY SECTOR ON ECONOMIC SYSTEM OF GUNUNGKIDUL DISTRICT IN 1993 - 2008

    Directory of Open Access Journals (Sweden)

    Mamat Rahmat

    2012-12-01

    Full Text Available This study was conducted to explore the role of forestry sector in the economic system of Gunungkidul district. The Location Quotient (LQ Analysis, Income Multiplier Effect Value, and Klassen Typology Analysis were employed to analyze the role of the forestry sector. The data were regional income of Gunungkidul district and Yogyakarta Province from 1993 to 2008, including the economic crisis period from 1997 to 1998. The result showed that forestry sector was an important sector in economic development of Gunungkidul district. LQ analysis indicated that forestry became a basic sector since pre-economic crisis period until post-economic crisis (1993 - 2008. Prior to the economic crisis, forestry sector generated the highest income multiplier effect value. However, the value dropped during and after the economic crisis. The economic crisis had an influence on the development pattern classification of forestry sector. Before economic crisis, forestry sector was classified as a developed sector (quadrant I with the growth and shared to GDRP in Gunungkidul were higher than that in Yogyakarta Province. Meanwhile, since the economic crisis, forestry sector fell into the lower class as a stagnant sector.

  17. Twin cities institutional issues study cogenerated hot water district heating

    Energy Technology Data Exchange (ETDEWEB)

    Sundberg, R. E.; Leas, R.; Kolb, J. O.

    1979-01-01

    Community district heating, utilizing hot water produced through electrical/thermal cogeneration, is seen as an integral part of Minnesota's Energy Policy and Conservation Plan. Several studies have been conducted which consider the technical and institutional issues affecting implementation of cogenerated district heating in the Minneapolis and St. Paul Metropolitan Area. The state of the technical art of cogenerated hot water district heating is assumed to be transferable from European experience. Institutional questions relating to such factors as the form of ownership, financing, operation, regulation, and product marketability cannot be transferred from the European experience, and have been the subject of an extensive investigation. The form and function of the Institutional Issues Study, and some of the preliminary conclusions and recommendations resulting from the study are discussed.

  18. Economies of scale in the Korean district heating system: A variable cost function approach

    International Nuclear Information System (INIS)

    Park, Sun-Young; Lee, Kyoung-Sil; Yoo, Seung-Hoon

    2016-01-01

    This paper aims to investigate the cost efficiency of South Korea’s district heating (DH) system by using a variable cost function and cost-share equation. We employ a seemingly unrelated regression model, with quarterly time-series data from the Korea District Heating Corporation (KDHC)—a public utility that covers about 59% of the DH system market in South Korea—over the 1987–2011 period. The explanatory variables are price of labor, price of material, capital cost, and production level. The results indicate that economies of scale are present and statistically significant. Thus, expansion of its DH business would allow KDHC to obtain substantial economies of scale. According to our forecasts vis-à-vis scale economies, the KDHC will enjoy cost efficiency for some time yet. To ensure a socially efficient supply of DH, it is recommended that the KDHC expand its business proactively. With regard to informing policy or regulations, our empirical results could play a significant role in decision-making processes. - Highlights: • We examine economies of scale in the South Korean district heating sector. • We focus on Korea District Heating Corporation (KDHC), a public utility. • We estimate a translog cost function, using a variable cost function. • We found economies of scale to be present and statistically significant. • KDHC will enjoy cost efficiency and expanding its supply is socially efficient.

  19. District heating with SLOWPOKE energy systems

    International Nuclear Information System (INIS)

    Lynch, G.F.

    1988-03-01

    The SLOWPOKE Energy System, a benign nuclear heat source designed to supply 10 thermal megawatts in the form of hot water for local heating systems in buildings and institutions, is at the forefront of these developments. A demonstration unit has been constructed in Canada and is currently undergoing an extensive test program. Because the nuclear heat source is small, operates at atmospheric pressure, and produces hot water below 100 degrees Celcius, intrinsic safety features will permit minimum operator attention and allow the heat source to be located close to the load and hence to people. In this way, a SLOWPOKE Energy System can be considered much like the oil- or coal-fired furnace it is designed to replace. The low capital investment requirements, coupled with a high degree of localization, even for the first unit, are seen as attractive features for the implementation of SLOWPOKE Energy Systems in many countries

  20. Uncertainties in the daily operation of a district heating plant

    DEFF Research Database (Denmark)

    Sorknæs, Peter

    , such as CHP. It will therefore likely be increasingly important to increase the value per operation hour. The value can be increased by offering balancing for the electricity system. This in turn increases the uncertainties in the daily operation planning of the DH system. In this paper the Danish DH plant...... Ringkøbing District Heating is used as a case to investigate what costs market uncertainties can incur on a DH plant. It is found that the market uncertainties in a 4 months simulated period increased Ringkøbing District Heatings costs by less than 1%. Several factors are however not included in this paper....

  1. Is Swedish district heating operating on an integrated market? – Differences in pricing, price convergence, and marketing strategy between public and private district heating companies

    International Nuclear Information System (INIS)

    Åberg, M.; Fälting, L.; Forssell, A.

    2016-01-01

    The deregulation of the Swedish electricity market in 1996 made it possible to operate municipal district heating commercially. Until that time district heating had been organized mainly as municipal utilities. After 1996 district heating is instead expected to function on a market. In competitive and integrated markets, prices are expected to be equal, or converging. To find out if district heating operates on an integrated market the differences in price levels, price convergence, price strategy, and business goals, among municipal, private and state owned district heating companies are investigated. Price statistics was used along with results from a questionnaire that was answered by representatives for 109 Swedish district heating companies. The results show that prices among district heating systems do not converge significantly and that variations in prices among municipal systems are larger than among private and state owned systems. Furthermore, despite the fact that district heating is supposed to be commercial, a vast majority of district heating companies apply cost-based pricing and not market pricing. The municipal companies give priority to political goals before financial goals. The conclusion is that a Swedish integrated market for heat has not yet evolved, and some district heating price-controlling mechanism is necessary. - Highlights: • Price statistics and owner type data were used along with results from a questionnaire. • Results show that prices among district heating systems do not converge. • Municipal district heating companies still apply cost-based pricing to a large extent. • District heating companies are not operating on an integrated market for heat. • Some price-controlling mechanism for district heating is necessary.

  2. The radiation safety assessment of the heating loop of district heating reactors

    International Nuclear Information System (INIS)

    Liu Yuanzhong

    1993-01-01

    The district heating reactors are used to supply heating to the houses in cities. The concerned problems are whether the radioactive materials reach the heated houses through heating loop, and whether the safety of the dwellers can be ensured. In order to prevent radioactive materials getting into the heated houses, the district heating reactors have three loops, namely, primary loop, intermediate loop, and heating loop. In the paper, the measures of preventing radioactive materials getting into the heating loop are presented, and the possible sources of the radioactivity in the water of the intermediate loop and the heating loop are given. The regulatory aim limit of radioactive concentration in the water of the intermediate loop is put forward, which is 18.5 Bq/l. Assuming that specific radioactivity of the water of contaminated intermediate loop is up to 18.5 Bq/l, the maximum concentration of radionuclides in water of the heating loop is calculated for the normal operation and the accident of district heating reactor. The results show that the maximum possible concentration is 5.7 x 10 -3 Bq/l. The radiation safety assessment of the heating loop is made out. The conclusions are that the district heating reactors do not bring any harmful impact to the dwellers, and the safety of the dwellers can be safeguarded completely

  3. Co-sponsored second quarter progress review conference on district heating

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-01-01

    A summary of the progress review conference on district heating and cooling systems is presented. The agenda and lists of speakers and attendees are presented. A history of district heating and some present needs and future policies are given and an excerpt from the National District Heating Program Strategy (DOE, March 1980) is included. Following the presentation, District Heating and Cooling Systems Program, by Alan M. Rubin, a fact sheet on DOE's Integrated Community Energy Systems Program and information from an oral presentation, District Heating and Cooling Systems for Communities Through Power Plant Retrofit Distribution Network, are given. The Second Quarterly Oral Report to the US DOE on the District Heating and Cooling Project in Detroit; the executive summary of the Piqua, Ohio District Heating and Cooling Demonstration Project; the Second Quarterly Report of the Moorehead, Minnesota District Heating Project; and the report from the Moorehead, Minnesota mayor on the Hot Water District Heating Project are presented.

  4. Simulation and analysis of a meshed district heating network

    International Nuclear Information System (INIS)

    Vesterlund, Mattias; Toffolo, Andrea; Dahl, Jan

    2016-01-01

    Highlights: • A method for the detailed simulation of meshed district heating network is described. • The simulation models developed in Simulink are fully modular. • The complex meshed network in Kiruna (Sweden) is used as case study. • The simulation results are validated against the experimental data. • The patterns of mass and heat flows are visualized and analysed. - Abstract: The flow distribution in a district heating network tends to become no longer obvious when system design is developed and its complexity increased. As a consequence, the network owner, often the local energy company, is in need of a simulation program to have the possibility of analysing network behaviour and expand the understanding about the operation of district heating system. In this paper, a simulation tool developed in MATLAB/Simulink is applied in order to analyse the flow distribution in the district heating network of the town of Kiruna (Sweden). The network in Kiruna has been developing since the 60s and is today a complex network with a meshed structure, i.e. it is formed by a set of loops from which secondary branches depart. The simulation tool is part of a methodology that has specifically been developed to analyse the flow pattern in such kind of networks without altering their physical structure, and it is expected to be a valuable tool for the redesign of the network in the forthcoming relocation of some of the urban districts. The results about the current network configuration show that only a few pipes in the network are exceeding the levels of heat flow recommended by pipe manufacturers. The largest drops in pressure and temperature from the heat production site to the nodes serving the main consumer areas are within 1.2 bar and 9 °C in the days of highest demand.

  5. Impact of Next Generation District Heating Systems on Distribution Network Heat Losses: A Case Study Approach

    Science.gov (United States)

    Li, Yu; Rezgui, Yacine

    2018-01-01

    District heating (DH) is a promising energy pathway to alleviate environmental negative impacts induced by fossil fuels. Improving the performance of DH systems is one of the major challenges facing its wide adoption. This paper discusses the heat losses of the next generation DH based on the constructed Simulink model. Results show that lower distribution temperature and advanced insulation technology greatly reduce network heat losses. Also, the network heat loss can be further minimized by a reduction of heat demand in buildings.

  6. Potential of waste heat in Croatian industrial sector

    Directory of Open Access Journals (Sweden)

    Bišćan Davor

    2012-01-01

    Full Text Available Waste heat recovery in Croatian industry is of the highest significance regarding the national efforts towards energy efficiency improvements and climate protection. By recuperation of heat which would otherwise be wasted, the quantity of fossil fuels used for production of useful energy could be lowered thereby reducing the fuel costs and increasing the competitiveness of examined Croatian industries. Another effect of increased energy efficiency of industrial processes and plants is reduction of greenhouse gases i.e. the second important national goal required by the European Union (EU and United Nations Framework Convention on Climate Change (UNFCCC. Paper investigates and analyses the waste heat potential in Croatian industrial sector. Firstly, relevant industrial sectors with significant amount of waste heat are determined. Furthermore, significant companies in these sectors are selected with respect to main process characteristics, operation mode and estimated waste heat potential. Data collection of waste heat parameters (temperature, mass flow and composition is conducted. Current technologies used for waste heat utilization from different waste heat sources are pointed out. Considered facilities are compared with regard to amount of flue gas heat. Mechanisms for more efficient and more economic utilization of waste heat are proposed. [Acknoledgment. The authors would like to acknowledge the financial support provided by the UNITY THROUGH KNOWLEDGE FUND (UKF of the Ministry of Science, Education and Sports of the Republic of Croatia and the World Bank, under the Grant Agreement No. 89/11.

  7. Quantitative thermography and methods for in-situ determination of heat losses from district heating networks

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, B. [ed.

    1996-11-01

    The course and seminar summarizing application of infrared thermography in district heating systems control gathered Danish specialists with 5 contributions on the subject. Maintenance of the heat distribution pipelines and thermographic inspection of the systems are essential in order to avoid heat losses. (EG)

  8. Thermal performance of solar district heating plants in Denmark

    DEFF Research Database (Denmark)

    Furbo, Simon; Perers, Bengt; Bava, Federico

    2014-01-01

    The market for solar heating plants connected to district heating systems is expanding rapidly in Denmark. It is expected that by the end of 2014 the 10 largest solar heating plants in Europe will be located in Denmark. Measurements from 23 Danish solar heating plants, all based on flat plate solar...... collectors mounted on the ground, shows measured yearly thermal performances of the solar heating plants placed in the interval from 313 kWh/m² collector to 493 kWh/m² collector with averages for all plants of 411 kWh/m² collector for 2012 and 450 kWh/m² collector for 2013. Theoretical calculations show...... of the cost/performance ratio for solar collector fields, both with flat plate collectors and with concentrating tracking solar collectors. It is recommended to continue monitoring and analysis of all large solar heating plants to document the reliability of the solar heating plants. It is also recommended...

  9. Heat demand mapping and district heating grid expansion analysis: Case study of Velika Gorica

    Directory of Open Access Journals (Sweden)

    Dorotić Hrvoje

    2017-01-01

    Full Text Available Highly efficient cogeneration and district heating systems have a significant potential for primary energy savings and the reduction of greenhouse gas emissions through the utilization of a waste heat and renewable energy sources. These potentials are still highly underutilized in most European countries. They also play a key role in the planning of future energy systems due to their positive impact on the increase of integration of intermittent renewable energy sources, for example wind and solar in a combination with power to heat technologies. In order to ensure optimal levels of district heating penetration into an energy system, a comprehensive analysis is necessary to determine the actual demands and the potential energy supply. Economical analysis of the grid expansion by using the GIS based mapping methods hasn’t been demonstrated so far. This paper presents a heat demand mapping methodology and the use of its output for the district heating network expansion analysis. The result are showing that more than 59% of the heat demand could be covered by the district heating in the city of Velika Gorica, which is two times more than the present share. The most important reason of the district heating's unfulfilled potential is already existing natural gas infrastructure.

  10. Heat demand mapping and district heating grid expansion analysis: Case study of Velika Gorica

    Science.gov (United States)

    Dorotić, Hrvoje; Novosel, Tomislav; Duić, Neven; Pukšec, Tomislav

    2017-10-01

    Highly efficient cogeneration and district heating systems have a significant potential for primary energy savings and the reduction of greenhouse gas emissions through the utilization of a waste heat and renewable energy sources. These potentials are still highly underutilized in most European countries. They also play a key role in the planning of future energy systems due to their positive impact on the increase of integration of intermittent renewable energy sources, for example wind and solar in a combination with power to heat technologies. In order to ensure optimal levels of district heating penetration into an energy system, a comprehensive analysis is necessary to determine the actual demands and the potential energy supply. Economical analysis of the grid expansion by using the GIS based mapping methods hasn't been demonstrated so far. This paper presents a heat demand mapping methodology and the use of its output for the district heating network expansion analysis. The result are showing that more than 59% of the heat demand could be covered by the district heating in the city of Velika Gorica, which is two times more than the present share. The most important reason of the district heating's unfulfilled potential is already existing natural gas infrastructure.

  11. Barriers and enablers to geothermal district heating system development in the United States

    International Nuclear Information System (INIS)

    Thorsteinsson, Hildigunnur H.; Tester, Jefferson W.

    2010-01-01

    According to the US Energy Information Administration, space and hot water heating represented about 20% of total US energy demand in 2006. Given that most of this demand is met by burning natural gas, propane, and fuel oil, an enormous opportunity exists for directly utilizing indigenous geothermal energy as a cleaner, nearly emissions-free renewable alternative. Although the US is rich in geothermal energy resources, they have been frequently undervalued in America's portfolio of options as a means of offsetting fossil fuel emissions while providing a local, reliable energy source for communities. Currently, there are only 21 operating GDHS in the US with a capacity of about 100 MW thermal. Interviews with current US district heating operators were used to collect data on and analyze the development of these systems. This article presents the current structure of the US regulatory and market environment for GDHS along with a comparative study of district heating in Iceland where geothermal energy is extensively utilized. It goes on to review the barriers and enablers to utilizing geothermal district heating systems (GDHS) in the US for space and hot water heating and provides policy recommendations on how to advance this energy sector in the US.

  12. Ground Source Geothermal District Heating and Cooling System

    Energy Technology Data Exchange (ETDEWEB)

    Lowe, James William [Ball State Univ., Muncie, IN (United States)

    2016-10-21

    Ball State University converted its campus from a coal-fired steam boiler district heating system to a ground source heat pump geothermal district system that produces simultaneously hot water for heating and chilled water for cooling. This system will include the installation of 3,600 four hundred feet deep vertical closed loop boreholes making it the largest ground source geothermal district system in the country. The boreholes will act as heat exchangers and transfer heat by virtue of the earth’s ability to maintain an average temperature of 55 degree Fahrenheit. With growing international concern for global warming and the need to reduce worldwide carbon dioxide loading of the atmosphere geothermal is poised to provide the means to help reduce carbon dioxide emissions. The shift from burning coal to utilizing ground source geothermal will increase electrical consumption but an overall decrease in energy use and reduction in carbon dioxide output will be achieved. This achievement is a result of coupling the ground source geothermal boreholes with large heat pump chiller technology. The system provides the thermodynamic means to move large amounts of energy with limited energy input. Ball State University: http://cms.bsu.edu/About/Geothermal.aspx

  13. A control model for district heating networks with storage

    NARCIS (Netherlands)

    Scholten, Tjeert; De Persis, Claudio; Tesi, Pietro

    2014-01-01

    In [1] pressure control of hydraulic networks is investigated. We extend this work to district heating systems with storage capabilities and derive a model taking the topology of the network into account. The goal for the derived model is that it should allow for control of the storage level and

  14. Magneto-Inductive Underground Communications in a District Heating System

    DEFF Research Database (Denmark)

    Meybodi, Soroush Afkhami; Nielsen, Jens Frederik Dalsgaard; Bendtsen, Jan Dimon

    2011-01-01

    Feasibility of underground data communications is investigated by employing magnetic induction as the key technology at physical layer. Realizing an underground wireless sensor network for a district heating plant motivates this research problem. The main contribution of the paper is to find the ...

  15. Introduction of renewable energy sources in the district heating system of Greece

    Directory of Open Access Journals (Sweden)

    Nikolaos Margaritis

    2016-06-01

    Full Text Available The district heating (DH system of Greece, mainly supported from lignite fired stations, is facing lately significant challenges. Stricter emission limits, decreased efficiency due to old age and increased costs are major challenges of the lignite sector and are expected to result in the decommissioning of several lignite-fired units in the coming years. As a result, managers of DH networks are currently investigating alternative scenarios for the substitution of thermal power that it is expected to be lost, through the integration of Renewable Energy Sources (RES into the system. In this paper, the DH systems of Kozani and Ptolemaida are examined regarding possible introduction of RES. The first study examines district heating of Kozani and alternative future options for covering a part of city’s thermal load whereas the second study refers to a biomass CHP plant (ORC technology, 1MWe, 5MWth to be powered from a biomass mixture (wood chips and straw.

  16. Industrial excess heat for district heating in Denmark

    DEFF Research Database (Denmark)

    Bühler, Fabian; Petrovic, Stefan; Karlsson, Kenneth Bernard

    2017-01-01

    Excess heat is available from various sources and its utilisation could reduce the primary energy use. The accessibility of this heat is however dependent amongst others on the source and sink temperature, amount and potential users in its vicinity. In this work a new method is developed which an...

  17. A modeling approach for district heating systems with focus on transient heat transfer in pipe networks

    DEFF Research Database (Denmark)

    Mohammadi, Soma; Bojesen, Carsten

    2015-01-01

    Increasing the building energy efficiency in recent years results in noticeably reduction in their heating demand. Combined with the current trend for utilizing low temperature heat sources, it raises the necessity of introducing a new generation of district heating [DH] systems with lowered...... km pipelines (supply and return pipes). At the first stage, the Studstrup DH system is developed in TERMIS, which is commercial software for district heating system simulation, and then the developed model is validated and compared with the results obtained from TERMIS and measurements. The TERMIS...

  18. Low Temperature District Heating Consumer Unit with Micro Heat Pump for Domestic Hot Water Preparation

    DEFF Research Database (Denmark)

    Zvingilaite, Erika; Ommen, Torben Schmidt; Elmegaard, Brian

    2012-01-01

    In this paper we present and analyse the feasibility of a district heating (DH) consumer unit with micro heat pump for domestic hot water (DHW) preparation in a low temperature (40 °C) DH network. We propose a micro booster heat pump of high efficiency (COP equal to 5,3) in a consumer DH unit...... in order to boost the temperature of the district heating water for heating the DHW. The paper presents the main designs of the suggested system and different alternative micro booster heat pump concepts. Energy efficiency and thermodynamic performance of these concepts are calculated and compared....... The results show that the proposed system has the highest efficiency. Furthermore, we compare thermodynamic and economic performance of the suggested heat pump-based concept with different solutions, using electric water heater. The micro booster heat pump system has the highest annualised investment (390 EUR...

  19. Heat Driven Cooling in District Energy Systems; Vaermedriven Kyla

    Energy Technology Data Exchange (ETDEWEB)

    Rydstrand, Magnus; Martin, Viktoria; Westermark, Mats [Royal Inst. of Technology, Stockholm (Sweden). Dept. of Chemical Engineering and Technology

    2004-07-01

    This report is reviewing different heat driven technologies for the production of cooling. It is shown that the supply of cooling gives the highest fuel utilization if heat from CHP production is used for the production of cooling instead of maximizing the electricity output in a condensing plant. High fuel utilization is reached since the direct production of cooling from heat is a thermodynamic shortcut as compared to the production of electricity as an intermediate product before cooling is produced. At direct production of cooling from heat it is possible to obtain 70 percent of the obtainable cooling of an ideal process. If electricity is produced from heat, 70 percent electricity could be obtained as compared to an ideal process. If this electricity would be used for the production of cooling 70 percent of the obtainable cooling in an ideal process would the result. The total production of cooling from heat with electricity as an intermediate product would therefore give 50 percent cooling as compared to an ideal process. Hence, heat driven cooling will give more cooling for a given fuel input. In the review of the different heat driven cooling options it was found that there are many alternatives suitable for different applications. Absorption cooling is suitable for water distributed cooling if the latent cooling load is low. Desiccant cooling is believed to have a large market in climates (applications) with high latent cooling loads. In the energy efficiency evaluation it is found that the highest fuel utilization is given for a central production of electricity using either district heating or district cooling as the energy carrier to supply cooling. In fact the potential of district heating as the energy carrier is thought to be the largest in large cities with humid climates. Further it is found that the chiller heat sink can contribute significantly to the cost in many applications, especially if water and/or electricity consumption are issues with

  20. The District Heating Regulation in Russia: Local Markets’ Reaction

    Directory of Open Access Journals (Sweden)

    Olga Valeryevna Dyomina

    2017-09-01

    Full Text Available The article explores ways of state regulation of natural monopolies, shows their generalized classification. Two main ways of direct regulation are described: costs-based and stimulating. It is shown that there is an overwhelming trend of changing ways of regulation to less state-controlled. On the example of the district heating market of Russia the article shows the failing of the acting costs-based type of regulation. It is concluded that the main task of changing regulation is destroying the connection between tariffs and heat producer’s costs. The alternative way for district heating reform is a stimulating type of regulation based on price limits (the price of ‘heat-only boilers’. The author made estimates of gains received as a result of the reform for participants of three largest district heating markets of the Far East. It is shown that annual increase rates of tariffs for consumers will be: Vladivostok – 5.0%, Khabarovsk – 8.8%, Blagoveshchensk – 11.1%. The estimates do not support the estimates of Russian Ministry of Energy specialists according to which the annual increase rate is expected to be about 0.6%

  1. The Thermos program for nuclear reactors specialized in district heating

    International Nuclear Information System (INIS)

    Lerouge, B.

    1976-01-01

    Many studies have been made in France on the use of nuclear heat for district heating. After a brief account of the problems raised by the use of thermal waste from big nuclear power stations, the quantitative and qualitative needs of heating networks are analyzed and the Thermos project described. This is a very robust reactor of the pool type, with an output of 100MW, supplying low-pressure water at 100 deg C. The advantages from the aspects of safety and economy are described, and the present state of the project and its possible developments summarized [fr

  2. Cooling and recovery of heat from underground railway tunnels for district heating

    OpenAIRE

    Davies, G; Maidment, GG; Dennis, W; Ajileye, A; Grice, J

    2017-01-01

    Temperatures in London’s underground railway tunnels are rising year on year and new energy efficient, cooling solutions are needed. The MICAH (Metropolitan Integrated Cooling and Heating) project involves investigating the feasibility of combining cooling and ventilation of London’s underground tunnels with recovering and reuse of the waste heat to supply a district heating network (DHN). A suitable site from the underground network has been identified, close to a DHN, to which the heat can ...

  3. A new district heating system in the city of Bolanzo

    DEFF Research Database (Denmark)

    Mazzocato, Alessandro; Li, Hongwei; Marchiori, S.

    2014-01-01

    performance. This research aims to assess the potential energy saving of temperature and peak heating load reduction in the Bolzano’s DHC network. Historical performance data from district heating (DH) users were collected and residential building were classified based on construction year and energy......In the context of the EU project “Sinfonia”, that aims to reduce Bolzano’s primary energy consumption up to 40%, SEL AG, an Italian energy company is planning to extend the existing district heating and cooling (DHC) network and explore strategies to improve efficiency, environmental, and economic...... performance. The thermal properties of the identified representative buildings were used to develop an indoor climate and energy simulation model by means of IDA-ICE software. The simulation model was validated through real on-site temperature measurements. The potential reduction of temperature supply...

  4. Technical assessment of electric heat boosters in low-temperature district heating based on combined heat and power analysis

    DEFF Research Database (Denmark)

    Cai, Hanmin; You, Shi; Wang, Jiawei

    2018-01-01

    This paper provides a technical assessment of electric heat boosters (EHBs) in low-energy districts. The analysis is based on a hypothetical district with 23 terraced single-family houses supplied by both a lowtemperature district heating (LTDH) network and a low-voltage network (LVN). Two case...... studies are provided to show the active role of EHBs in a smart energy system (SES). The first case compares annual heat and power flow analyses for LTDH at five supply temperature levels, focusing on their impacts. The results show that district heating network (DHN) losses can be reduced by 35......% if the supply temperature is reduced from 70 C to 50 C, but the LVN peak power will have to be increased by up to 2% using heat boosting. The second case further aggregates EHBs to provide a fuel shift (FS) service for the DHN. The results show that while LVN peak power was increased by up to 4.3%, the basic...

  5. Hybrid district heating system with heat supply from nuclear source

    International Nuclear Information System (INIS)

    Havelka, Z.; Petrovsky, I.

    1987-01-01

    Several designs are described of heat supply from large remote power sources (e.g., WWER-1000 nuclear power plants with a 1000 MW turbine) to localities where mainly steam distribution networks have been built but only some or none networks for hot water distribution. The benefits of the designs stem from the fact that they do not require the conversion of the local steam distribution system to a hot water system. They are based on heat supply from the nuclear power plant to the consumer area in hot water of a temperature of 150 degC to 200 degC. Part of the hot water heat will be used for the production of low-pressure steam which will be compressed using heat pumps (steam compressors) to achieve the desired steam distribution network specifications. Water of lower temperature can be used in the hot water network. The hot water feeder forms an automatic pressure safety barrier in heat supply of heating or technological steam from a nuclear installation. (Z.M.). 5 figs., 9 refs

  6. Long-term impacts of heat demand reductions within the Aarhus district heating area

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Möller, Bernd

    equipment into consideration. By reducing the demands there are many long-term benefits for society in the form of reduced resource use and production capacity. In this article the long-term benefits are examined in the concrete case of the Danish district heating area Aarhus. The analysis takes departure...... that the benefits of implementing heat saving measures are large, especially savings in fuel and production capacity are substantial in the concrete case of Aarhus. In other district heating areas the result will be different, where some have large amounts of excess heat from e.g. local industries or waste...... the current heat price that is taken into account. Often the long-term costs are not reflected in the heat price and since the benefits of investing in heat saving measures last for a long time, the decision should be based on long-term planning taking reinvestments in production capacity and distribution...

  7. Architecture for internet enabled measurements in a district heating substation laboratory

    OpenAIRE

    Jomni, Yassin; Yliniemi, Kimmo; van Deventer, Jan; Delsing, Jerker

    2005-01-01

    An architecture for the energy measurement and control and monitoring at a district heating substation is propsoed. A district heating substation is comprised of a set of sensors and actuators crutial for the well being of the substation. We want to make the data from the sensors available over the internet and provide access to the control system of the district heating substation over the internet. This technology will be implemented in a district heating laboratory being constructed at Lul...

  8. Current state of utilization of nuclear sources for district heating

    International Nuclear Information System (INIS)

    Zlatnansky, J.

    1987-01-01

    The use of heat from nuclear power sources is considered as the basic trend of development in district heating within the framework of the long-term prospective plan of the development of the fuel and power complex in the CSSR. Of the total consumption of heat in the year 2005 (648,000 TJ), nuclear power units are to deliver 54,000 TJ. At present, heat is being generated by the Jaslovske Bohunice nuclear power plant and supplied to Trnava, and a heat duct is being built from this plant to Leopoldov and Hlohovce, and prospectively to Bratislava. The Dukovany nuclear power plant is expected to supply heat to Brno, the Mochovce nuclear power plant to Levice and Nitra, and the Temelin nuclear power plant to Ceske Budejovice. Other nuclear power plants will in the future also supply heat (Kecerovce, Blahutovice and Opatovice). The technical and economic evaluation is tabulated of heat deliveries from all said nuclear power plants. It is stated that after the year 2000, AST 500 nuclear heating plants should be deployed for supplying heat to areas out of reach of nuclear power plants and reconstructed fossil-fuel power plants. (Z.M.). 2 tabs

  9. An emerging computer sector in the Tenth District

    OpenAIRE

    Jason Henderson

    1998-01-01

    Computer industries have been an important facet of the nation's current economic expansion. During the 1990s, the computer sector has added almost three-quarters of a million jobs across the country, creating high-paying new positions and spawning new opportunities for the American entrepreneur.

  10. Evaluation of noise levels in manufacturing sectors in Thika district ...

    African Journals Online (AJOL)

    Noise is considered as any unwanted sound that may adversely affect the health and wellbeing of individuals or populations exposed. This study assessed the magnitude of occupational noise exposures to workers in different manufacturing sectors in Thika District‐Kenya. Systematic random sampling was used to select 8 ...

  11. Ties that stand the test of time. Energy consulting at real estates supplied with district heating; Pruefe, wer sich lange bindet. Energieberatung bei fernwaermeversorgten Immobilien

    Energy Technology Data Exchange (ETDEWEB)

    Dorss, Werner [ARCADIS Deutschland GmbH, Frankfurt am Main (Germany). Abt. Energiewirtschaftsrecht

    2011-05-15

    In the energy consulting increased attention is required when the property of the customer is connected to a district heating network or if an appropriate supply contract with the energy supplier is to be made for the first time or extended. Since the district heating sector is not exposed to competition till today, there is a danger that customers are faced in contracts with arbitrary pricing and doubtful conditions.

  12. The application of ground source heat pumps to a subdivision-wide district heating system

    International Nuclear Information System (INIS)

    Ciavaglia, L.

    2005-01-01

    Design guidelines for economic ground source heat pumps (GSHP) in district energy systems were presented. The broad economics of using central GSHP in a community district energy system were examined. Design parameters needed to utilize GSHP in district energy system were outlined. The sensitivity of energy prices and the costs of major capital were reviewed. District heating load duration curves were outlined. It was suggested that varying GSHP capacity from 0 to 100 per cent of load was advisable. In addition, capacity should be balanced with gas boiler technology. The amortizing of capital within energy costs was recommended. It was suggested that the best scenario was a minimum of 50 per cent ground energy. Details of pipings and heat exchanger costs were presented, along with costs for gas boilers and gas costs for the district energy system. Charts of current costing and reduction of piping capital were included. It was concluded that GSHP can be a viable component of a district energy system, as a GSHP based district energy system can provide more stable energy prices than conventional fossil fuel systems. It was suggested that sizing of GSHP at, or near, 40 per cent of peak demand provided optimal conditions with respect to energy cost and use of earth energy. tabs., figs

  13. Dynamic behavior of district heating systems. 1. Report

    International Nuclear Information System (INIS)

    Kunz, J.

    1993-01-01

    In this study a comprehensive model simulating the dynamic behavior of an entire district heating system has been developed. The model consists of four partial models, namely a model of the hydraulic behavior of a heat distribution network, another model of the thermal behavior of this network, a model of the heat generation plants and one of the heat consumers connected to the system. For the hydraulic simulation of the distribution network, a classical steady state approach has proved to be sufficient. The evolution of the temperatures in the network is given by the equation of transport. A numerical resolution scheme, which is adapted to the special case of a heat distribution network was developed for this equation. The model developed for the heating plant is simple but it is sufficiently detailed to determine the operation of its elements. A more complex model would take much more calculation time, but with such a simple model, it is possible to include it in the global model of the entire system. Each heat consumer is represented by a simple one cell model. The difficulty in such an approach is to determine the characteristics of each building in a simple manner. A classification, which allows to find the essential parameters from few and easily available data, has been defined. This model is not sufficiently accurate to calculate the thermal behavior of one specific building but it allows to determine the average dynamic evolution of the heat demand for a set of buildings with a good precision.The developed models have been programmed on a personal computer and the entire district heating network of the city of Lausanne has been simulated with this calculation code. Measurements have been taken on this network and the comparison with calculated results has allowed to calibrate the model. The comparison of measurements and calculations shows, that each part of the system is simulated realistically by the proposed model. (author) figs., tabs., refs

  14. Feasibility analysis of geothermal district heating for Lakeview, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    1980-12-23

    An analysis of the geothermal resource at Lakeview, Oregon, indicates that a substantial resource exists in the area capable of supporting extensive residential, commercial and industrial heat loads. Good resource productivity is expected with water temperatures of 200{degrees}F at depths of 600 to 3000 feet in the immediate vicinity of the town. Preliminary district heating system designs were developed for a Base Case serving 1170 homes, 119 commercial and municipal buildings, and a new alcohol fuel production facility; a second design was prepared for a downtown Mini-district case with 50 commercial users and the alcohol plant. Capital and operating costs were determined for both cases. Initial development of the Lakeview system has involved conducting user surveys, well tests, determinations of institutional requirements, system designs, and project feasibility analyses. A preferred approach for development will be to establish the downtown Mini-district and, as experience and acceptance are obtained, to expand the system to other areas of town. Projected energy costs for the Mini-district are $10.30 per million Btu while those for the larger Base Case design are $8.20 per million Btu. These costs are competitive with costs for existing sources of energy in the Lakeview area.

  15. Plug and Play Process Control of a District Heating System

    DEFF Research Database (Denmark)

    Trangbaek, Klaus; Knudsen, Torben; Skovmose Kallesøe, Carsten

    2009-01-01

    The main idea of plug and play process control is to initialise and reconfigure control systems automatically. In this paper these ideas are applied to a scaled laboratory model of a district heating pressure control system.  First of all this serves as a concrete example of plug and play control......, secondly some of the first techniques developed for these problems are demonstrated by experiments. The main emphasis is on incremental modelling and control in order to make it possible to ``plug'' in a new sensor or actuator and make it ``play'' automatically.......The main idea of plug and play process control is to initialise and reconfigure control systems automatically. In this paper these ideas are applied to a scaled laboratory model of a district heating pressure control system.  First of all this serves as a concrete example of plug and play control...

  16. On-line corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Richter, Sonja; Thorarinsdottir, R.I.; Hilbert, Lisbeth Rischel

    2004-01-01

    Traditionally corrosion monitoring in district heating systems has been performed offline via weight loss coupons. These measurements give information about the past and not the present situation and require long exposure time (weeks or months). The good quality of district heating medium makes...... corrosion monitoring a challenge. Under normal conditions the pH is high (app. 9), conductivity is low (app. 10-200 µS/cm) and the concentration of dissolved oxygen is negligible. The low corrosion rates (in the order of µm/y) are difficult to measure and furthermore, factors such as hydrogen sulphide......), Electrochemical Noise (EN) and Zero Resistance Ammetry (ZRA). Electrochemical Resistance (ER) has also been used to measure corrosion. The method traditionally only measures corrosion off-line but with newly developed high-sensitive ER technique developed by MetriCorr in Denmark, on-line monitoring is possible...

  17. Straw fired district heating plants in Denmark. Facts and figures

    International Nuclear Information System (INIS)

    1996-05-01

    A series of analyses and comparisons of technical, operational and financial and environmental conditions relating to straw-fired district heating and cogeneration plants in Denmark during the period of May 1993 to June 1995. The report provides an insight into the potentials of straw as a source of energy, particularly in the case of countries where the cultivation of cereals represents a major part of the agricultural economy. (AB)

  18. Innovation in Russian District Heating: Opportunities, Barriers, Mechanisms

    OpenAIRE

    Andrey Kovalev; Liliana Proskuryakova

    2014-01-01

    Contrary to more advanced countries, Russia’s district heating hardly embraces radical innovations. Moving forward with breakthrough solutions, even if they have proven their effectiveness at leading European companies and are supported by federal and regional authorities, encounters significant obstacles. These obstacles include inflexible corporate management, including when interacting with customers, and inexperience in creating internal corporate startups and managing risks in the early ...

  19. Online, real-time corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.

    2005-01-01

    The corrosion control in district heating systems is today performed primarily with control of the water quality. The corrosion rate is kept low by assuring low dissolved oxygen concentration, high pH and low conductivity. Corrosion failures can occur, e.g. as a result of unknown oxygen ingress......, precipitation of deposits or crevices. The authors describe methods used for on-line monitoring of corrosion, cover the complications and the main results of a Nordic project....

  20. On-line Corrosion Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Richter, Sonja; Thorarinsdottir, R.I.; Hilbert, Lisbeth Rischel

    2005-01-01

    The corrosion control in district heating systems is today performed primarily with control of the water quality. The corrosion rate is kept low by assuring low dissolved oxygen concentration, high pH and low conductivity. Corrosion failures can occur, e.g. as a result of unknown oxygen ingress......, precipitation of deposits or crevices. The authors describe methods used for on-line monitoring of corrosion, cover the complications and the main results of a Nordic project....

  1. Geothermal district heating in Turkey: The Gonen case study

    International Nuclear Information System (INIS)

    Oktay, Zuhal; Aslan, Asiye

    2007-01-01

    The status of geothermal district heating in Turkey and its future prospects are reviewed. A description is given of the Gonen project in Balikesir province, the first system to begin citywide operation in the country. The geology and geothermal resources of the area, the history of the project's development, the problems encountered, its economic aspects and environmental contributions are all discussed. The results of this and other such systems installed in Turkey have confirmed that, in this country, heating an entire city based on geothermal energy is a significantly cleaner, cheaper option than using fossil fuels or other renewable energy resources. (author)

  2. District heating plants in Europe: Recent experience and innovations

    International Nuclear Information System (INIS)

    De Comelli, G.

    1992-01-01

    This paper contains a critical review of recent experience and innovative features encountered in some European district heating plants. The increased application of cogeneration is pointed out, with reference to traditional, as well as, more recent technology which makes use of combined gas-steam cycles. An example of a combined gas-steam cycle is schematically described. The relevance of fluidized bed combustion and interconnection of heat distribution grids, and their consequences to the environmentally-safe and economical employment of the plants, are evidenced

  3. Implementing Geothermal Plants in the Copenhagen District Heating System

    DEFF Research Database (Denmark)

    Jensen, Louise Overvad; Hallgreen, Christine Erikstrup; Larsen, Esben

    2003-01-01

    The possibility of implementing geothermal heating in the Copenhagen district-heating system is assessed. This is done by building up general knowledge on the geological factors that influence the development of useable geothermal resources, factors concerning the exploration and utilization...... of geothermal energy in Denmark as well as the Danish potential, which, in former investigations, has been found to be around 100.000 PJ annually, and the economical potential is less, about 15 PJ/year. Since a considerable amount of the Danish power supply is tied to weather and the demand for heating......, an increasing demand for flexibility has been raised. Implementing geothermal heating would improve the flexibility in the Eastern Danish power system. Based on this information, as well as, on the hourly values of the expected production and consumption in 2010 and 2020, a model of the Copenhagen power...

  4. Preliminary business plan: Plzen district heating system upgrade

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-06-01

    The district heating system of the City of Plzen, Czech Republic, needs to have physical upgrades to replace aging equipment and to comply with upcoming environmental regulations. Also, its ownership and management are being changed as a result of privatization. As majority owner, the City has the primary goal of ensuring that the heating needs of its customers are met as reliably and cost-effectively as possible. This preliminary business plan is part of the detailed analysis (5 reports in all) done to assist the City in deciding the issues. Preparation included investigation of ownership, management, and technology alternatives; estimation of market value of assets and investment requirements; and forecasting of future cash flow. The district heating system consists of the Central Plzen cogeneration plant, two interconnected heating plants [one supplying both hot water and steam], three satellite heating plants, and cooperative agreements with three industrial facilities generating steam and hot water. Most of the plants are coal-fired, with some peaking units fired by fuel oil.

  5. Flexible use of electricity in heat-only district heating plants

    Directory of Open Access Journals (Sweden)

    Erik Trømborg

    2017-01-01

    Full Text Available European energy systems are in a period of significant transition, with the increasing shares of variable renewable energy (VRE and less flexible fossil-based generation units as predominant factors. The supply-side changes are expected to cause large short-term electricity price volatility. More frequent periods of low electricity prices may mean that electric use in flexible heating systems will become more profitable, and such flexible heating systems may, in turn, improve the integration of increasing shares of VRE. The objective of this study is to analyze the likely future of Nordic electricity price levels and variations and how the expected prices might affect the use of electricity and thermal storage in heat-only district heating plants. We apply the North European energy market model Balmorel to provide scenarios for future hourly electricity prices in years with normal, high, and low inflow levels to the hydro power system. The simulation tool energyPRO is subsequently applied to quantify how these electricity price scenarios affect the hourly use of thermal storage and individual boilers in heat-only district heating plants located in Norway. The two studied example plants use wood chips or heat pump as base load representing common technologies for district heating in Norway. The Balmorel results show that annual differences in inflow is still a decisive factor for Norwegian and Nordic electricity prices in year 2030 and that short-term (daily price variability is expected to increase. In the plant-level simulations, we find that tank storage, which is currently installed in only a few district heating plants in Norway, is a profitable flexibility option that will significantly reduce the use of fossil peak load in both biomass and heat-pump-based systems. Installation of an electric boiler in addition to tank storage is profitable in the heat pump system due to the limited capacity of the heat pump. Electricity will hence, to a

  6. Recent district heating and cooling scheme and use of discharged heat

    Energy Technology Data Exchange (ETDEWEB)

    Chiba, Takanori (Takenaka Corp., Osaka, (Japan))

    1989-08-05

    In order to promote the development of the district heating and cooling (DHC) business, a reasonable unit price for heat sales should be established. For this purpose, it is important to use the most effective urban heat recovery system and adopt every possible measure, and maintain low operational costs which affect the heat unit price. This paper outlines the background, types and features of those heat recovery systems, and a representative district heat source facility using discharged heat to explain the features as an example. The background of DHC which uses discharged heat, is due to the circumstances of the overpopulation or concentration of urban population. As examples of DHC facility using urban discharged heat, uses of discharged heat in waste incineration plants and underground cables are listed. As for the uses of discharged heat in individual building; those in underground stores, electric room, elevator machine room, computer room, intermediate water facility, and local substation are listed. DHC facility using the heat from river is also expected to be completed in the near future. 2 refs., 11 figs., 1 tab.

  7. Heat planning for fossil-fuel-free district heating areas with extensive end-use heat savings

    DEFF Research Database (Denmark)

    Harrestrup, Maria; Svendsen, S.

    2014-01-01

    is a theoretical investigation of the district heating system in the Copenhagen area, in which heat conservation is related to the heat supply in buildings from an economic perspective. Supplying the existing building stock from low-temperature energy resources, e.g. geothermal heat, might lead to oversized......The Danish government plans to make the Danish energy system to be completely free of fossil fuels by 2050 and that by 2035 the energy supply for buildings and electricity should be entirely based on renewable energy sources. To become independent from fossil fuels, it is necessary to reduce...... the energy consumption of the existing building stock, increase energy efficiency, and convert the present heat supply from fossil fuels to renewable energy sources. District heating is a sustainable way of providing space heating and domestic hot water to buildings in densely populated areas. This paper...

  8. Master plan study - District heating Sillamaee municipality. Estonia. Final report

    International Nuclear Information System (INIS)

    1997-03-01

    The main deficiencies of the district heating system in Sillamae (Estonia) were identified as being inefficiency of the heat and power production plant, which has a very low capacity, lack of means for consumers to control their energy consumption due to the existing constant flow system, pollution from heat and power production based on oil shale, water and heat losses from the network and unclear agreements between the Silmet factory and Sillamae municipality. The available capital for funding is limited. It was investigated where in the system investments would have the greatest effect. A scenario where heat is supplied from individual gas-fired boilers was calculated. A financially viable scenario would be to change from cogeneration of heat and power (CHP) based on oil shale to either individual natural gas supply or peat-fueled heat production. The Sillamae municipality and the Estonian government should agree on a solution for Sillamae. There will be a cash flow problem if the project is implemented. This can be partly solved by introducing a longer loan period. it is expected that there will be no substantial changes in the consumers' heat demand in the 'do nothing'scenario, and in other scenarios ca. 520 Tj/p.a. from the Solmet factory, 530 Tj/p.a. from the town and 260 Tj/p.a. as heat losses, totaling 1310 Tj/p.a.. In another scenario - the introduction of natural gas - the town's heat demand will be 530 Tj/p.a. and there will be no heat losses. More detailed studies of environmental impacts should be undertaken

  9. Regulating district heating in Romania: Legislative challenges and energy efficiency barriers

    International Nuclear Information System (INIS)

    Poputoaia, Diana; Bouzarovski, Stefan

    2010-01-01

    Many states in Eastern and Central Europe (ECE) possess extensive district heating (DH) networks that were constructed during the days of communist rule in order to provide a universally accessible energy service that supported Soviet development policies. But the post-communist transition was marked by the exacerbation of the sector's numerous technical, economic, regulatory and environmental problems, accompanied by its abandonment in favour of alternative methods of domestic heating. Recent efforts to increase the use of DH in ECE as a result of environmental and energy security concerns have taken place in an absence of critical, context-sensitive research. The purpose of this paper is to explore the legal aspects of post-communist DH reforms in Romania, with the aim of identifying some of the governance challenges faced by state authorities in managing the sector. In broader terms, we seek to explore the extent to which the Romanian legislative framework is in a position to promote energy efficiency in DH. This has been achieved via an analysis of formal policy documents, government decrees, strategic documents and laws pertaining to this sector, as published and subsequently amended in the Official Gazette. The conclusions of the paper identify the key regulatory issues in the sector-especially with respect to the tariff setting process and the division of competences among different organisations in it-while suggesting a set of policy steps and general restructuring approaches that could help overcome the current situation.

  10. A transition perspective on alternatives to coal in Chinese district heating

    Directory of Open Access Journals (Sweden)

    Jingjing Zhang

    2015-06-01

    Full Text Available China accounts for half of the world’s annual coal consumption. Coal is the primary energy source for heating in urban areas, particularly in northern China. This causes significant challenges for urban air quality problems in China and greenhouse gases emissions. Urban district heating (DH systems penetration is very high in northern China. It supplies space heating to more than 80% of urban buildings in the area. Unlike the electricity and transportation sectors, the heating sector has received little attention from policy makers and researchers in China, DH systems are an enabling infrastructure which facilitates energy efficiency improvements and the use of renewable energy sources. This study explores the dynamics and possibility to expand alternative energy sources (natural gas, biomass, direct geothermal heat, ground-source heat pump, municipal waste heat, industrial waste heat for DH in China. We apply an analytical framework largely based on the multi-level perspective in socio-technical transitions theory, in which transitions are interpreted as the result of the functioning of niche, regime and landscape elements, and interactions between them. The study provides an integrated picture of the socio-technical structure and functioning of DH in China. The results show that an energy transition in Chinese DH systems has barely started. The system is characterised by stability of the coal-based DH regime, while a number of alternative niches are struggling to emerge. Among these, natural gas is the most successful example. However, at local level different niches present opportunities in terms of physical availability, economic viability and technical capacity to address changes in landscape pressures. A sustainable heat roadmap based on integrated energy planning and policy attention at the national level could be developed as one mechanism for instigating a much needed energy transition in DH in China.

  11. Low-temperature nuclear heat applications: Nuclear power plants for district heating

    International Nuclear Information System (INIS)

    1987-08-01

    The IAEA reflected the needs of its Member States for the exchange of information in the field of nuclear heat application already in the late 1970s. In the early 1980s, some Member States showed their interest in the use of heat from electricity producing nuclear power plants and in the development of nuclear heating plants. Accordingly, a technical committee meeting with a workshop was organized in 1983 to review the status of nuclear heat application which confirmed both the progress made in this field and the renewed interest of Member States in an active exchange of information about this subject. In 1985 an Advisory Group summarized the Potential of Low-Temperature Nuclear Heat Application; the relevant Technical Document reviewing the situation in the IAEA's Member States was issued in 1986 (IAEA-TECDOC-397). Programme plans were made for 1986-88 and the IAEA was asked to promote the exchange of information, with specific emphasis on the design criteria, operating experience, safety requirements and specifications for heat-only reactors, co-generation plants and power plants adapted for heat application. Because of a growing interest of the IAEA's Member States about nuclear heat employment in the district heating domaine, an Advisory Group meeting was organized by the IAEA on ''Low-Temperature Nuclear Heat Application: Nuclear Power Plants for District Heating'' in Prague, Czechoslovakia in June 1986. The information gained up to 1986 and discussed during this meeting is embodied in the present Technical Document. 22 figs, 11 tabs

  12. Achieving low return temperature for domestic hot water preparation by ultra-low-temperature district heating

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Svendsen, Svend

    2017-01-01

    District heating (DH) is a cost-effective method of heat supply, especially to area with high heat density. Ultra-low-temperature district heating (ULTDH) is defined with supply temperature at 35-45 degrees C. It aims at making utmost use of the available low-temperature energy sources. In order ...

  13. The potential to supply low temperature district heating to existing building area

    DEFF Research Database (Denmark)

    Li, Hongwei; Svendsen, Svend

    2013-01-01

    Low-temperature district heating (LTDH) has the advantages as reduced network heat loss, improved quality match between energy supply and energy demand, and increased utilization of low-grade waste heat and renewable energy. The LTDH represents the next generation district heating (DH) system...

  14. Application of combined heat and power in Malaysia Industrial Sector

    International Nuclear Information System (INIS)

    Zaredah Hashim; Faridah Mohd Taha

    2010-01-01

    Malaysia is still working on continuing its economic growth especially in the industrial sector in order to achieve vision 2020. The rapid industrialization process has caused increment in the energy demand, which simultaneously increases carbon dioxide (CO 2 ) emissions. Energy efficient technologies are strongly needed for reducing the energy requirement and to avoid the depleting of energy resources. This project focused on the application of integrated resource planning (IRP) in industrial sector using Combined Heat and Power (CHP), as a strategy for Demand Side Management (DSM). This approach is another way for meeting near and future energy requirement in Malaysia's industrial sector. Two scenarios which are Business As Usual (BAU) and CHP were developed using End Use Model EUM), to forecast the energy demand and CO 2 emission in Malaysia's industries. The effectiveness of the proposed method is then simulated using Long Range Energy Alternative Planning System (LEAP) software and Comparative Model for Projects of Engineering Economics and Energy Environmental Development (COMPEED) analysis. Evaluations were based on the potential of energy saving and CO 2 reduction. Scope of research was limited to pulp and paper industrial sub sector. The research data were extracted from Energy Audit Reports conducted by Malaysia Energy Center (PTM). An engineering calculation was demonstrated. Two designs of CHP applications for the pulp and paper industrial sector are according to heating and electricity sizing. It was found that the most energy efficient and CO 2 reduction for Malaysia's industrial sector is the CHP based on heating requirement. The method was found to be able of save fuel and GHG emission compared to the reference case. (author)

  15. Electricity eliminates rust from district heat pipes. The new deoxidation method works on radiators

    Energy Technology Data Exchange (ETDEWEB)

    Sonninen, R.; Leisio, C.

    1996-11-01

    Oxygen dissolving in district heating water through district heat pipes and pipe joints made of plastic corrodes many small and medium-size district heating systems, resulting in heat cuts in the buildings connected to these systems. IN some cases, corrosion products have even circulated back to district heating power plants, thus hampering heat generation in the worst of cases. People residing in blocks of flats where some radiator components are made of plastic also face a similar problem, though on a smaller scale. A small and efficient electrochemical deoxidation cell has now been invented to eliminate this nuisance, which occurs particularly in cold winter weather. (orig.)

  16. Effects of heat and electricity saving measures in district-heated multistory residential buildings

    International Nuclear Information System (INIS)

    Truong, Nguyen Le; Dodoo, Ambrose; Gustavsson, Leif

    2014-01-01

    Highlights: • We analyzed the potential for energy savings in district heated buildings. • Measures that reduce more peak load production give higher primary energy savings. • Efficient appliances increase heat demand but give net primary energy savings. • Efficient appliances give the largest net primary energy savings. - Abstract: The effects of heat and electricity saving measures in district-heated buildings can be complex because these depend not only on how energy is used on the demand side but also on how energy is provided from the supply side. In this study, we analyze the effects of heat and electricity saving measures in multistory concrete-framed and wood-framed versions of an existing district-heated building and examine the impacts of the reduced energy demand on different district heat (DH) production configurations. The energy saving measures considered are for domestic hot water reduction, building thermal envelope improvement, ventilation heat recovery (VHR), and household electricity savings. Our analysis is based on a measured heat load profile of an existing DH production system in Växjö, Sweden. Based on the measured heat load profile, we model three minimum-cost DH production system using plausible environmental and socio-political scenarios. Then, we investigate the primary energy implications of the energy saving measures applied to the two versions of the existing building, taking into account the changed DH demand, changed cogenerated electricity, and changed electricity use due to heat and electricity saving measures. Our results show that the difference between the final and primary energy savings of the concrete-framed and wood-framed versions of the case-study building is minor. The primary energy efficiency of the energy saving measures depends on the type of measure and on the composition of the DH production system. Of the various energy saving measures explored, electricity savings give the highest primary energy savings

  17. District heating as a source of flexibility in the Nordic electricity market

    DEFF Research Database (Denmark)

    Skytte, Klaus; Sneum, Daniel Møller; Sandberg, Eli

    2016-01-01

    to come in order to reach the ambitious renewable energy deployment targets in the Nordic and Baltic countries. Transformation to an energy system increasingly based on VRE will escalate the requirement for flexible operation of the entire energy system, including improved integration among energy sectors....... District heating (DH) is an important sector in the Nordic energy system and has a large potential for increased flexible operation in relation to the future electricity system. This potential is only partly exploited today. One reason for this is the differences in regulatory framework conditions for DH...... compared to the electricity market, e.g. different energy taxes, which may hinder the potential benefits from systems integration and lower the realisable potentials....

  18. District heating and cooling: a 28-city assessment

    Energy Technology Data Exchange (ETDEWEB)

    Meshenberg, M.J.

    1983-08-01

    Findings of a project that assessed the potential for construction of district heating and cooling (DHC) systems in 28 US cities are presented. The project sought to determine whether DHC could promote local community and economic development. In the preliminary assessment, 17 of the cities identified up to 23 projects that could be built within three to five years. Most of these projects would rely on nonscarce heat sources such as refuse or geothermal energy, and to improve financial feasibility, the majority would cogenerate electricity along with heat. Many would use existing power plants or industrial boilers to hold down capital costs. Overall, the projects could generate as amany as 24,000 jobs and retain $165 million that otherwise could leave the communities, thereby helping to stabilize local economies.

  19. Thermodynamic analysis and performance assessment of an integrated heat pump system for district heating applications

    International Nuclear Information System (INIS)

    Soltani, Reza; Dincer, Ibrahim; Rosen, Marc A.

    2015-01-01

    A Rankine cycle-driven heat pump system is modeled for district heating applications with superheated steam and hot water as products. Energy and exergy analyses are performed, followed by parametric studies to determine the effects of varying operating conditions and environmental parameters on the system performance. The district heating section is observed to be the most inefficient part of system, exhibiting a relative irreversibility of almost 65%, followed by the steam evaporator and the condenser, with relative irreversibilities of about 18% and 9%, respectively. The ambient temperature is observed to have a significant influence on the overall system exergy destruction. As the ambient temperature decreases, the system exergy efficiency increases. The electricity generated can increase the system exergy efficiency at the expense of a high refrigerant mass flow rate, mainly due to the fact that the available heat source is low quality waste heat. For instance, by adding 2 MW of excess electricity on top of the targeted 6 MW of product heat, the refrigerant mass flow rate increases from 12 kg/s (only heat) to 78 kg/s (heat and electricity), while the production of 8 MW of product heat (same total output, but in form of heat) requires a refrigerant mass flow rate of only 16 kg/s. - Highlights: • A new integrated heat pump system is developed for district heating applications. • An analysis and assessment study is undertaken through exergy analysis methodology. • A comparative efficiency evaluation is performed for practical applications. • A parametric study is conducted to investigate how varying operating conditions and state properties affect energy and exergy efficiencies.

  20. Technoeconomic analysis of a biomass based district heating system

    International Nuclear Information System (INIS)

    Zhang, H.; Ugursal, V.I.; Fung, A.

    2005-01-01

    This paper discussed a proposed biomass-based district heating system to be built for the Pictou Landing First Nation Community in Nova Scotia. The community centre consists of 6 buildings and a connecting arcade. The methodology used to size and design heating, ventilating and air conditioning (HVAC) systems, as well as biomass district energy systems (DES) were discussed. Annual energy requirements and biomass fuel consumption predictions were presented, along with cost estimates. A comparative assessment of the system with that of a conventional oil fired system was also conducted. It was suggested that the design and analysis methodology could be used for any similar application. The buildings were modelled and simulated using the Hourly Analysis Program (HAP), a detailed 2-in-1 software program which can be used both for HVAC system sizing and building energy consumption estimation. A techno-economics analysis was conducted to justify the viability of the biomass combustion system. Heating load calculations were performed assuming that the thermostat was set constantly at 22 degrees C. Community centre space heating loads due to individual envelope components for 3 different scenarios were summarized, as the design architecture for the buildings was not yet finalized. It was suggested that efforts should be made to ensure air-tightness and insulation levels of the interior arcade glass wall. A hydronic distribution system with baseboard space heating units was selected, comprising of a woodchip boiler, hot water distribution system, convective heating units and control systems. The community has its own logging operation which will provide the wood fuel required by the proposed system. An outline of the annual allowable harvest covered by the Pictou Landing Forestry Management Plan was presented, with details of proposed wood-chippers for the creation of biomass. It was concluded that the woodchip combustion system is economically preferable to the

  1. Design of energy-efficient buildings using interaction between Building Simulation Programme and Energy Supply Simulations for District Heating

    DEFF Research Database (Denmark)

    Christensen, Jørgen Erik; Dalla Rosa, Alessandro; Nagla, Inese

    potential of the energy saving in the society it is very important to address the decisive involvement of the end-users. The human behaviour is the factor that affects the most the energy use in low-energy buildings and should be included in energy simulations. The results can then be linked to programs...... simulating the energy supply system in order to support the design of CO2-free communities. The cases considered, although referring to the Danish tradition in the construction sector and to the Danish climate, have a general value and are adaptable to other situations and countries. The results demonstrate...... that there is a large potential for distributing energy in areas with energy efficient buildings. As a measure for the feasibility of district heating, the linear heat density can be used as a representative value, and the results show that it is possible to supply heat with low-energy district heating networks...

  2. Geothermal District Heating System City of Klamath Falls

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, Paul J.; Rafferty, Kevin

    1991-12-01

    The city of Klamath Falls became interested in the possibility of a establishing geothermal district heating system for downtown government buildings in January 1977. Since that time, the project has undergone some controversial and interesting developments that may be of educational value to other communities contemplating such a project. The purpose and content of this article is to identify the historical development of the project; including the design of the system, well owner objections to the project, aquifer testing, piping failure, and future expansion and marketing incentives. The shallow geothermal reservoir in Klamath falls extends for at least 6.8 miles in a northwest-southeast direction, as shown on Figure 1, with a width of about 2 miles. More than 550 thermal wells ranging in depth from about 10 to 2,000 ft, and obtaining or contacting water from 70 to 230oF, have been drilled into the reservoir. The system is not geologically homogeneous. Great variations in horizontal permeability and many vertical discontinuities exist because of stratigraphy and structure of the area. Basalt flows, eruptive centers, fluvial and lacustrine deposits, diatomite and pyroclastic materials alternate in the rock column. Normal faults with large throw (estimated up to 1,700 ft) are spaced less than 3,300 ft apart and appear to be the main avenue of vertical movement of hot fluids. In order to more effectively utilize this resource, the city of Klamath Falls decided in 1978 to apply for a federal grant (Program Opportunity Notice to cost share field experiment projects) to construct a geothermal district heating system that would deliver geothermal fluids to areas not located on the resource. In 1977, several Geo-Heat Center staff members visited Reykjavik, Iceland, to study the design of their geothermal district heating systems. This was in part the basis for the conceptual design and feasibility study (Lund, 1979) of a downtown commercial district. The main difference

  3. Korean district heating. Part 2: Investigation of the consumption pattern in a substation at Korea District Heating Corporation at the turn of the year 1994/95

    Energy Technology Data Exchange (ETDEWEB)

    Joensson, Mats; Olsson, Nils

    1996-05-01

    This thesis, which is the second part of two, analyses the consumption pattern and the conditions for district heating in the Republic of Korea at the turn of the year 1994-95. It is based on a study made in Seoul at Korea District Heating Corporation which is the largest district heating utility in Korea. District heating was introduced in the 80s because of the environmental advantages. In 1994 KDHC provided 340 000 households with district heating. KDHC receives most of its thermal energy from combined heat and power plants which use natural gas as fuel. One substation was chosen for the investigation and temperature, flow, and pressure were measured. A typical Korean substation has heat exchangers connected in parallel in only one step and the apartment complexes use floor heating for internal heating. The space heating load shows a linear relation to the outdoor temperature. The hot tap-water consumption shows a highly varying pattern with peak loads in the morning and evening. There were also an oscillating pattern for some of the temperatures and flows caused by poor regulation. DH suits very well to Korea with its climate and the overpopulated cities. KDHC:s expansion will help to make Korea one of the leading countries in modern district heating. 10 refs, 36 figs, 11 tabs

  4. LeBreton Flats district heating: Institutional issues

    Energy Technology Data Exchange (ETDEWEB)

    Gerow, L.B.; Bernstein, H.

    1981-12-01

    Despite the growing popularity in Europe of district heating as an alternative to conventional systems, a number of institutional barriers blocked the road to its successful implementation in Canada. These hurdles include questions of ownership, operation/administration, consumer accountability, financial arrangements, and general consumer acceptance of a new technology. In deciding on ownership, the major issues were legal. Provincial laws to be complied with included The Municipal Franchises Act, The Public Utilities Act, The Municipal Act and The Ontario Municipal Board Act. The operation and administration of the project were also beset with legal complications. The relevant laws were The Boilers and Pressure Vessels Act, and The Environmental Assessment Act. How to charge individual users (consumer accountability) raised a number of technical problems including metering and rate-setting for hot water distribution, and heat borrowing between units. The report recommends that groups planning to implement district heating are advised to allow plenty of lead time for obtaining approvals and franchising arrangements so as not to jeopardize construction schedules. 3 refs.

  5. Exergoenvironmental analysis for a geothermal district heating system: An application

    International Nuclear Information System (INIS)

    Keçebaş, Ali

    2016-01-01

    Energy sources are of great importance in relation to pollution of the world. The use of renewable energy resources and the creation of more efficient energy systems make great contributions to the prevention of greenhouse gases. Recently, many studies indicate that the energy conversion systems have many advantages in terms of technical and economic point of view. In near future, environmental impact is going to play an important role in the selection/design of such energy resources and systems. In this study, the Afyon GDHS (geothermal district heating system) having actual operating conditions is investigated at the component level in terms of environmental impact by using exergoenvironmental analysis. Moreover, the effects of ambient and wellhead temperatures on the environmental impacts of the system are discussed. The results show that a great part of total environmental impact of the system occurs from the exergy destructions of the components. Therefore, the environmental impacts can be reduced by improving their exergetic efficiencies instead of design changes of the system components. The environmental impacts of the system are reduced when the ambient temperature decreases and the wellhead temperature increases. Thus, it might not be necessary to conduct separately the exergoenvironmental analysis for different ambient temperatures. - Highlights: • Using exergoenvironmental analysis in a geothermal district heating for the first time. • Evaluating environmental impact of a geothermal district heating system. • Discussing the effects of ambient and wellhead temperatures on the environmental impact. • Total environmental impact of the system occurs from exergy destructions of components. • The exergoenvironmental analysis can be done only once for all the ambient temperatures.

  6. Primary energy use for heating in the Swedish building sector-Current trends and proposed target

    International Nuclear Information System (INIS)

    Johansson, P.; Nylander, A.; Johnsson, F.

    2007-01-01

    One goal of the Swedish energy policy is to reduce the amount of electricity used for heating in the building sector. This means to reduce the primary energy used for heating which in this paper is analyzed in the context of various heating technologies and CO 2 emissions. The analysis is applied to a region in Sweden (southern Sweden) for which detailed information on the energy infrastructure (the capital stock of the buildings and heating systems together with geographical variations in heat intensity) is available from a previous work [Johansson, P., Nylander, A., Johnsson, F., 2005. Electricity dependency and CO 2 emissions from heating in the Swedish building sector-current trends in conflict with governmental policy? Energy policy] and which is large enough to be assumed representative for Sweden as a whole. The detailed mapping of the energy infrastructure allows a good estimate on the rate at which the energy system can be expected to be replaced with respect to economical lifetime of the capital stock (the year 2025 in this case). Two scenarios are investigated; a target scenario for which energy savings are employed (e.g. improving climate shell in buildings) and oil and most of the electricity used for heating purposes are phased out and a second for which the current trend in the heating market continues. In the target scenario it is shown that although only applying commercially competitive heating technologies, it is possible to achieve a 47% reduction in primary energy use for heating with a 34% decrease in heat demand together with significant reduction in CO 2 emissions. However, the scenario which continues the current trends on the heating market instead yields an increase (of about 10%) in primary energy use (reduction in conversion efficiency) of the heating system of the region over the period studied, in spite of a slight decrease in heat demand (9%, mainly due to energy efficiency measures) as well as in CO 2 emissions. In light of the

  7. Environmental Assessment for the Bison School District Heating Plant Project, Institutional Conservation Program (ICP)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    This environmental assessment analyzes the environmental impacts of replacing the Bison, South Dakota School District`s elementary school and high school heating system consisting of oil-fired boilers and supporting control system and piping

  8. Design of SES-10 nuclear reactor for district heating

    International Nuclear Information System (INIS)

    Cuttler, J.M.

    1991-03-01

    The SES-10 units are unpressurized, pool-type nuclear reactors of 10MW rating, designed for supplying energy to hot water district heating systems, economically and without pollution. Water for heat distribution is brought to a maximum temperature of 85 degrees C. Conventional heating units supplement the output from SES-10 units for peak load and during maintenance. The SES-10 is housed in a low-cost building, with a double-walled pool in the ground. A naturally circulating primary system and a pumped secondary system transport heat from the reactor to the distribution system. The unit is fully automated and easy to maintain. Because of the many active and passive safety features, it is feasible to license the SES-10 for operation in a city and easy to explain it to the public for their acceptance. The core lasts approximately 43 months at a capacity factor of 70%, and the cost of heat is expected to be 2 to 2.5 cents/kWh

  9. Design of SES-10 nuclear reactor for district heating

    International Nuclear Information System (INIS)

    Cuttler, J.M.

    1991-01-01

    The SES-10 units are unpressurized, pool-type nuclear reactors of 10 MW rating, designed for supplying energy to hot water district heating systems, economically and without pollution. Water for heat distribution is brought to a maximum temperature of 85 o C. Conventional heating units supplement the output from SES-10 units for peak load and during maintenance. The SES-10 is housed in a low-cost building, with a double-walled pool in the ground. A naturally circulating primary system and a pumped secondary system transport heat from the reactor to the distribution system. The unit is fully automated and easy to maintain. Because of the many active and passive safety features, it is feasible to license the SES-10 for operation in a city and easy to explain it to the public for their acceptance. The core lasts approximately 43 months at a capacity factor of 70%, and the cost of heat is expected to be 2 to 2.5 cents/kWh. (author) 8 figs

  10. Klamath County geo-heating district feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P.J.; Lund, J.W.; Culver, G.G.

    1977-01-01

    The results are presented of an agreement between the Klamath County Commissioners and Oregon Institute of Technology Geo-Heat Utilization Center for the conceptual design, cost analysis and plan for space heating a number of public buildings in Klamath Falls, Oregon with geothermal hot water. This project was principally aimed at supplying geothermal heat to ten city and county buildings by hot water extracted from the existing museum well. The supply system is also designed to include the post office and a new building to be built in the vicinity of the courthouse. The fluid would be piped from the museum well to three liquid-to-liquid heat exchangers and returned to the area of the producing well for reinjection into the same aquifer. The study also considered space heating of 98 additional buildings in the downtown business district equivalent to the ten public buildings and incorporating a snow removal grid on Main Street between Eleventh and Fourth Streets. The geothermal fluid would be supplied from wells in the vicinity of Old Fort Road (city police pistol range) and returned for reinjection. Based on the study, the Center has concluded that no major resource or engineering difficulties exist that would prevent the ten-building project from being completed successfully with a significant long-term savings in both scarce fossil fuels and total heating costs. A direct environmental benefit of the large-scale plan would be a significant reduction in air pollutants (16 tons per year) from the burning of natural gas. For a capital investment of approximately $548,900 the delivery system, conversion of building heating systems and waste disposal could be accomplished for the ten buildings with potential expansion to twelve.

  11. Natural refrigerants. Future heat pumps for district heating; Naturliga koeldmedier. Framtida vaermepumpar foer fjaerrvaerme

    Energy Technology Data Exchange (ETDEWEB)

    Ingvarsson, Paul; Steen Ronnermark, Ingela [Fortum Teknik och Miljoe AB, Stockholm (Sweden); Eriksson, Marcus [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Chemical Engineering and Environmental Science

    2004-01-01

    International work on refrigerants is aiming at phasing out HFC. The solution might be natural refrigerants. Within 15-20 years, when present heat pumps for district heating in Sweden are likely not in service any longer, it might still be good economy to install new heat pumps since only the machines need to be replaced. This report describes the possibilities to use natural refrigerants. A first screening resulted in further study on some hydrocarbons, ammonia and carbon dioxide. Water was considered to require too large volumes. In present plants it is practically not possible to use any natural refrigerants, partly because the compressors are not adapted. In new plants the situation is different. Today it is technically possible to install new heat pumps in the studied size, 15 MW{sub th}, using ammonia or hydrocarbons as refrigerant. But likely it is very difficult to get permits from authorities since the refrigerants are toxic or highly flammable. There is substantial international research on using carbon dioxide, and this refrigerant is also used in some applications. Carbon dioxide is used at high pressure and in a trans-critical process. Surprisingly, it turned out that one compressor manufacturer considers it possible to supply a heat pump for district heating within 5 years. This development has taken place in Russia, mainly for domestic use. Thus, within 15 to 20 years there will probably exist a technique where carbon dioxide is used. However, more development is needed. Additionally, low district heating return temperatures are also needed to get an acceptable COP. The investment cost for a heat pump installation is considered to be approx. 30 % higher when using ammonia or propane compared to using R134a. When using carbon dioxide there is in the longer run potential to get lower cost than for R134a. The COPs are almost identical if the systems are properly designed. In the carbon dioxide case the COP is somewhat lower, but has a potential for

  12. Techno-economic analysis of a local district heating plant under fuel flexibility and performance

    DEFF Research Database (Denmark)

    Rudra, Souman; Rosendahl, Lasse

    2017-01-01

    Brovst is a small district in Denmark. This paper analyses the use of local renewable resources in the district heating systems of Brovst. The present use of fossil fuels in the Brovst district heating plant (DHP) represents an increasing environmental and climate-related load. Therefore......, an investigation has been made to reduce the use of fossil fuels for district heating system and make use of the local renewable resources (biogas, solar, and heat pump) for district heating purposes. In this article, the techno-economic assessment is achieved through the development of a suite of models......PRO, which has been used to analyze the integration of a large-scale energy system into the domestic district heating system. A model of the current work on the basis of information from the Brovst plant (using fossil fuel) is established and named as a reference option. Then, four other options...

  13. Cogeneration and District Heating. Best Practices for Municipalities

    International Nuclear Information System (INIS)

    Nuorkivi, A.; Constantinescu, T.

    2005-01-01

    District heating (DH) and cogeneration of heat power (CHP) are well known technologies in the energy business and are often included in municipal policies as well. Some of the major benefits of DH and CHP are less known and the barriers faced by further development of DH and CHP are substantial. The main barriers are institutional. Municipalities can play a powerful role in facilitating local DH and CHP development in order to achieve the economic and environmental benefits of DH and CHP. This report is produced to assist municipalities in promoting efficient and environmental beneficial DH and CHP. The focus of the report is on the economies in transition, where the institutional barriers are acute. The report addresses the issues of organisational framework, price regulation and financing, energy demand, rehabilitation of DH systems and benchmarking of DH and CHP. The municipality may influence the DH development by a number of means. The most important means, discussed in the various chapters of the report, are: (1) City planning impacts on the heat load density. A high density is an important factor for the economics of DH and city planning may promote DH in areas with high density and individual heating modes in the areas with low density; (2) Managing the building stock owned by the municipality to join the DH system and paying for the heating services; (3) Setting strategic goals for the District Heating Enterprise (DHE), which they usually own, regarding the quality and the costs of heating. The DHE shall be given sufficient resources to work towards such goals; (4) Providing guarantees for financing DH rehabilitation and development. The DHE may not have access to commercial credits without municipal guarantees; and, (5) Supporting the DHE management by giving operational independence, supervising the management performance regularly and encouraging the co-operation with other DHEs and equipment manufacturers. Examples provided in the report of

  14. Annex to Solar heat storages in district heating networks. Comprehensive list of Danish literature and R and D projects

    Energy Technology Data Exchange (ETDEWEB)

    Ellehauge, K. (Ellehauge og Kildemoes, AArhus (DK)); Engberg Pedersen, T. (COWI A/S, Kgs. Lyngby (DK))

    2007-07-15

    This annex relates to the report 'Solar heat storages in district heating networks', which has been elaborated to inform about the Danish experiences and findings on the use of central solar heating plants in district heating networks, especially with the focus on the development of the storage part of the systems. The report has been funded as part of the IEE PREHEAT cooperation and by Energinet.dk, project no. 2006-2-6750. (au)

  15. Air source absorption heat pump in district heating: Applicability analysis and improvement options

    International Nuclear Information System (INIS)

    Wu, Wei; Shi, Wenxing; Li, Xianting; Wang, Baolong

    2015-01-01

    Highlights: • Applicability of air source absorption heat pump (ASAHP) district heating is studied. • Return temperature and energy saving rate (ESR) in various conditions are optimized. • ASAHP is more suitable for shorter distance or lower temperature district heating. • Two options can reduce the primary return temperature and improve the applicability. • The maximum ESR is improved from 13.6% to 20.4–25.6% by compression-assisted ASAHP. - Abstract: The low-temperature district heating system based on the air source absorption heat pump (ASAHP) was assessed to have great energy saving potential. However, this system may require smaller temperature drop leading to higher pump consumption for long-distance distribution. Therefore, the applicability of ASAHP-based district heating system is analyzed for different primary return temperatures, pipeline distances, pipeline resistances, supplied water temperatures, application regions, and working fluids. The energy saving rate (ESR) under different conditions are calculated, considering both the ASAHP efficiency and the distribution consumption. Results show that ASAHP system is more suitable for short-distance district heating, while for longer-distance heating, lower supplied hot water temperature is preferred. In addition, the advantages of NH 3 /H 2 O are inferior to those of NH 3 /LiNO 3 , and the advantages for warmer regions and lower pipeline resistance are more obvious. The primary return temperatures are optimized to obtain maximum ESRs, after which the suitable distances under different acceptable ESRs are summarized. To improve the applicability of ASAHP, the integration of cascaded heat exchanger (CHX) and compression-assisted ASAHP (CASAHP) are proposed, which can reduce the primary return temperature. The integration of CHX can effectively improve the applicability of ASAHP under higher supplied water temperatures. As for the utilization of CASAHP, higher compression ratio (CR) is better in

  16. SUBSTATIONS OF DISTRICT HEATING SYSTEMS WITH PULSE COOLANT CIRCULATION

    Directory of Open Access Journals (Sweden)

    Andrey N. Makeev

    2017-01-01

    Full Text Available Abstract. Objectives The aim of the study is to generalise the results of the application of technologies and means for organising pulse coolant flow within a district heating system in order to increase its energy efficiency based on the organisation of local hydraulic shocks and the subsequent use of their energy to ensure the purification of heat energy equipment, intensify the heat transfer process and realise the possibility of transforming the available head from one hydraulic circuit to another. Methods Substations connecting the thermal power installations of consumers with heat networks via dependent and independent schemes are analytically generalised. The use of pulse coolant circulation is proposed as a means of overcoming identified shortcomings. Results Principal schemes of substations with pulse coolant circulation for dependent and independent connection of thermal power installations are detailed. A detailed description of their operation is given. The advantages of using pulse coolant circulation in substations are shown. The materials reflecting the results of the technical implementation and practical introduction of this technology are presented. Conclusion Theoretical analysis of the operation of the basic schemes of substations with pulse coolant circulation and the results of their practical application, as well as the materials of scientific works devoted to the use of the energy of a hydraulic impact and the study of the effect of pulse coolant flow on thermal and hydrodynamic processes, have yielded a combination of factors reflecting technical and economic rationality of application of pulse coolant circulation. 

  17. IMPACT OF HRM PRACTICES ON EMPLOYEE SATISFACTION IN BANKING SECTOR IN CHITTOOR DISTRICT

    OpenAIRE

    P.Suresh; Dr.T.Narayana Reddy

    2017-01-01

    Employee satisfaction plays a key role on both the individual and organisation. Employee satisfaction will result in improving organisation productivity. The present study is carried out to comprehend the effect of HRM Practices in banking sector. This study is based on both primary and secondary data, reviewing the literatures related to HRM Practices, employee satisfaction, in banks of chittoor district. The objective of the study focuses on understanding Effect of HRM practices on Employee...

  18. The state of HIV sector local governance in Malawi and Zambia: Evidence from five districts

    Directory of Open Access Journals (Sweden)

    Justin Steyn

    2014-07-01

    Full Text Available This paper encapsulates the outputs of a Swiss Agency for Development Cooperation (SDC funded project that aimed to improve the levels of HIV governance at the district level in Malawi and Zambia by encouraging public participation in an effort to more effective use of local resources. The methodology for this project, developed by the Institute for Democracy in Africa (Idasa and SDC, included a barometer which assessed perceptions of district HIV governance among key stakeholders. Perceptions were gathered on governance principles of effectiveness, efficiency, rule of law, accountability, participation and equity. The stakeholders ranged from administrators, political representatives, community-based organisations and the private sector on the supply side and citizens on the demand or beneficiary side. The findings of the research indicate specific sector governance issues that may be generalised to governance. Communication and transparency appear to be major issues underpinning the bottlenecks and shortcomings in the HIV sector governance at the district level. Information gaps have given rise to accountability deficits and coordination deficiencies. Addressing these matters would make more effective use of resources and lessen dependence on external funding sources.

  19. The Swiss heating reactor (SHR) for district heating of small communities

    International Nuclear Information System (INIS)

    Burgsmueller, P.; Jacobi, A.Jr.; Jaeger, J.F.; Klaentschi, M.J.; Seifritz, W.; Vuillemier, F.; Wegmann, F.

    1987-01-01

    With fossil fuel running out in a foreseeable future, it is essential to develop substitution strategies. Some 40-50 % of the heat demand in industrial countries is below 120 degrees C, for space heating and warm water production, causing a corresponding fraction of air pollution by SO 2 and to a lesser extent NO x if fossil fuels are used. Yet, contemporary LWR technology makes it feasible to supply a district heating network without basically new reactor development. Units in the power range 10-50 MW are most suitable for Switzerland, both in respect of network size and of the democratic decision making structure. A small BWR for heating purpose is being developed by parts of the Swiss Industry and the Swiss Federal Institute for Reactor Research (EIR). The economic target of 100-120 SFr/MWh heat at the consumer's seems achievable. (author)

  20. Individual Heating systems vs. District Heating systems: What will consumers pay for convenience?

    International Nuclear Information System (INIS)

    Yoon, Taeyeon; Ma, Yongsun; Rhodes, Charles

    2015-01-01

    For Korea's two most popular apartment heating systems – Individual Heating (IH) and District Heating (DH), – user convenience rests heavily on location of the boiler, availability of hot water, administration of the system, and user control of indoor temperature. A double-bounded dichotomous choice method estimates consumer value for convenience, in a hypothetical market. Higher-income more-educated consumers in more expensive apartments prefer DH. Cost-conscious consumers, who use more electrical heating appliances and more actively adjust separate room temperatures, prefer IH. With willingness-to-pay (WTP) defined as the price ratio between IH and DH, 800 survey respondents indicate a WTP of 4.0% for DH over IH. IH users unfamiliar with DH expect little greater convenience (0.1% WTP), whereas the WTP for DH users runs to 7.9%, demonstrating consumer loyalty. Quantified estimates of consumer preference and convenience can inform design of a full-cost-plus pricing system with a price cap. Results here indirectly predict the effect of abolishing regulations that exclusively establish district heating zones. Strategies to foster the many external benefits of DH systems should stress not their lower cost, but convenience, comfort, and safety. Higher installation costs still hamper DH expansion, so policy-makers could set policies to lower cost barriers to entry. - Highlights: • District Heating (DH) and Individual Heating (IH) systems differ in user convenience. • Difference of convenience is evaluated by a double-bounded dichotomous choice method. • Consumers are willing to pay a 4.03–12.52% higher rate to use DH rather than IH. • Consumers with high living standards prefer DH to IH, and show high consumer loyalty. • Strategies to foster DH systems should stress DH convenience over its lower cost.

  1. Energy supply and urban planning projects: Analysing tensions around district heating provision in a French eco-district

    International Nuclear Information System (INIS)

    Gabillet, Pauline

    2015-01-01

    Through the analysis of energy supply choices, this article explores the way in which energy priorities and their climate-related features are incorporated into urban public policy. These choices must take account of different factors, as is the case with district heating, which is justified as a vehicle of renewable energy while subject to pressure in eco-districts because its techno-economic balances are destabilised by falls in demand. Our study focuses particularly on the city of Metz (France), which has chosen district heating as the primary source for provision for the municipal area and for its first eco-district. We analyse the tensions within these choices, with particular attention to the way in which they are negotiated inside municipal departments and with the local energy operator. This enables us to explore the tensions in defining the scale that governs decisions and the linkages between energy-related and urban priorities. - Highlights: • Analyses of tensions in the choice of energy supplies for eco-districts. •District heating networks can be vehicles of renewable energy. • District heating networks are threatened by drops in energy consumption. • Energy supply issues oppose urban planning and energy policy in municipal departments. • Technical and financial adjustments can be made by the municipality to justify its energy choices

  2. Optimization of a local district heating plant under fuel flexibility and performance

    DEFF Research Database (Denmark)

    Rudra, Souman; Rosendahl, Lasse; From, Niels

    2011-01-01

    Brovst is a small district in Denmark. Based on the case of Brovst, this paper analyses the role of district heating in future Renewable Energy Systems. The present use of fossil fuels in the Brovst DHP (district heating plant) represents an increasing environmental and climate-related load. So......, an investigation has been made to reduce the use of fossil fuels for district heating system and make use of the local renewable resources (Biogas, Solar and Geothermal) for district heating purpose. In this article, the techno-economic assessment is achieved through the development of a suite of models...... that are combined to give cost and performance data for this district heating system. Different local fuels have been analyzed for different perspectives to find the way to optimize the whole integrated system in accordance with fuel availability and cost. This paper represents the energy system analysis mode...

  3. Optimization of a local district heating plant under fuel flexibility and performance

    DEFF Research Database (Denmark)

    Rudra, Souman; Rosendahl, Lasse; From, Niels

    2011-01-01

    Brovst is a small district in Denmark. Based on the case of Brovst, this paper analyses the role of district heating in future Renewable Energy Systems. The present use of fossil fuels in the Brovst DHP (district heating plant) represents an increasing environmental and climate-related load. So......, an investigation has been made to reduce the use of fossil fuels for district heating system and make use of the local renewable resources (Biogas, Solar and Geothermal) for district heating purpose. In this article, the techno-economic assessment is achieved through the development of a suite of models...... energyPRO which has been used to analyses the integration of large scale energy system into the domestic district heating system. A model of the current work on the basis of information from the plant (using fossil fuel) is established and named as a reference model. Then different solutions...

  4. A method for the simulation and optimization of district heating systems with meshed networks

    International Nuclear Information System (INIS)

    Vesterlund, Mattias; Dahl, Jan

    2015-01-01

    Highlights: • Process integration is used to develop method for modeling district heating. • A method to model complex district heating networks with loops is developed. • The flow distribution in loops in complex district heating network can be analyzed. • The influence from bottlenecks in complex district heating network can be analyzed. • Optimal heat production for a multisource district heating network can obtained. - Abstract: There are two main methods nowadays for modeling district heating systems, but a key disadvantage of both is that a real network containing loops cannot be described without artificial simplifications in order to eliminate those distinguishing features. However, loops are very common in mature networks that have developed a meshed structure, and make the distribution of mass and heat flows quite characteristic. For this reason, a new process integration method for modeling complex district heating systems containing loops is described in this paper. This method makes it possible to analyze how loops and bottlenecks affect the behavior of the network, as well as the distribution path of the thermal energy in it. The district heating system in the town of Kiruna (located in the north of Sweden) has a complex design with several loops and part of it is used in the paper as an example of application

  5. Restructuring and regulating district heating and cogeneration in transition economies

    International Nuclear Information System (INIS)

    Brendow, Klaus

    2004-01-01

    In summer 2004, the World Energy Council published a Study on 'Regulating district heating and cogeneration in central and eastern Europe'2, prepared by representatives from eleven economies in transition and two Nordic countries. The Task Force analysed twelve regulatory issues, country-by-country, on all internationally comparable basis. Regulatory progress on the road to more efficient, profitable, competitive and service-oriented heat supplies was described. Common concerns were identified: the need for independence of the regulator from policy and industry, improved coordination between central and local regulators and between environmental and energy authorities, access to grids, and a 'fair' sharing of CHP benefits among heat and electricity generation. Looking forward, the Task Force advocated a continued dialogue between decision makers, regulators, regulated industries and customers on: 1)the internalisation of DH/CHP benefits; 2)the future reduction of the density of regulation; 3) Joint implementation; 4)the compensation for public service obligations; 5)the elimination of old debt and stranded investments; 6) DH/CHP taxation; 7)privatisation; 8)the integration of DH/CHP in urban planning. A concluding WEC workshop in Moscow in March 2004 addressed recommendations to policy makers('Moscow Statement'). (Author)

  6. Competition in the market for space heating. District heating as the infrastructure for competition among fuels and technologies

    International Nuclear Information System (INIS)

    Grohnheit, Poul Erik; Gram Mortensen, Bent Ole

    2003-01-01

    None of the EU directives on liberalisation of the electricity and gas markets are considering the district heating systems, although the district heating networks offer the possibility of competition between natural gas and a range of other fuels on the market for space heating. Cogeneration of electricity and heat for industrial processes or district heating is a technology option for increased energy efficiency and thus reduction of CO 2 emissions. In the mid-1990s less than 10% of the electricity generation in the European Union was combined production with significant variations among Member States. These variations are explained by different national legislation and relative power of institutions, rather than difference in industrial structure, climate or urban physical structure. The 'single energy carrier' directives have provisions that support the development of combined heat and power (CHP), but they do not support the development and expansion of the district heating infrastructure. The article is partly based on a contribution to the Shared Analysis Project for the European Commission DG Energy, concerning the penetration of CHP, energy saving, and renewables as instruments to meet the targets of the Kyoto Protocol within the liberalised European energy market. The quantitative and legal differences of the heat markets in selected Member States are described, and the consequences of the directives are discussed. Finally, we summarise the tasks for a European policy concerning the future regulation of district heating networks for CHP, emphasising the need for rules for a fair competition between natural gas and district heating networks

  7. Comparison of district heating expansion potential based on consumer-economy or socio-economy

    DEFF Research Database (Denmark)

    Grundahl, Lars; Nielsen, Steffen; Lund, Henrik

    2016-01-01

    Recent studies show that a high share of district heating is an important part of a future sustainable energy system or smart energy system with a high renewable energy penetration. These studies also show socio-economic benefits of expanding the district heating coverage. However, in order...... to implement such an expansion, district heating needs to be economically feasible for the heat consumers. This aspect is often not investigated and hence it is unknown if calculations based on consumer-economy, where tax payment is included, will yield the same potential of expansion. This study identifies...... the differences in the expansion potential of district heating calculated with a socio-economic and a consumer-economic approach, respectively, in a case study of Denmark. By also investigating the consumer-economy of expanding district heating, a deeper insight is obtained of possible locations for expanding...

  8. Comparison of corrosion monitoring techniques in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Nielsen, Lars Vendelbo; Thorarinsdottir, R.I.

    2004-01-01

    Investigations aimed at evaluating monitoring techniques as a function of the specific water chemistry has been conducted as a part of a Nordic project focused on improving the quality of corrosion monitoring in municipal district heating. A combination of techniques has been selected to measure...... both general and localised corrosion. Electrochemical techniques (LPR, EIS) as well as direct techniques (high sensitive ER, weight loss, local crevice corrosion current) have been applied. The data show that the water quality in Danish systems is high resulting in low corrosion rates, but changes...... in the water quality induce localised corrosion. Useful monitoring results have been obtained with high sensitive ER technique (MetriCorr) and crevice corrosion measurements with the LOCORR cell (FORCE TECHNOLOGY)....

  9. Efficient numerical method for district heating system hydraulics

    International Nuclear Information System (INIS)

    Stevanovic, Vladimir D.; Prica, Sanja; Maslovaric, Blazenka; Zivkovic, Branislav; Nikodijevic, Srdjan

    2007-01-01

    An efficient method for numerical simulation and analyses of the steady state hydraulics of complex pipeline networks is presented. It is based on the loop model of the network and the method of square roots for solving the system of linear equations. The procedure is presented in the comprehensive mathematical form that could be straightforwardly programmed into a computer code. An application of the method to energy efficiency analyses of a real complex district heating system is demonstrated. The obtained results show a potential for electricity savings in pumps operation. It is shown that the method is considerably more effective than the standard Hardy Cross method still widely used in engineering practice. Because of the ease of implementation and high efficiency, the method presented in this paper is recommended for hydraulic steady state calculations of complex networks

  10. District heating marketing. Strategies in the heating market. 2. ed.; Fernwaerme-Marketing. Strategien im Waermemarkt

    Energy Technology Data Exchange (ETDEWEB)

    Marschalleck, Helmut [MVV Energie AG, Mannheim (Germany); Arndt, Andreas [EnBW Vertriebs- und Servicegesellschaft, Karlsruhe (Germany); Behm, Norman [Stadtwerke Rostock AG (Germany)] [and others

    2012-07-01

    The assistance in the strategic and operational planning of an individual marketing strategy in the district heating market is the focus of the book under consideration. Starting from the definition of the actual situation (market analysis and marketing potential) and the strategic goal, a marketing concept and a marketing mix (product policy, pricing policy, distribution policy as well as communication policy) is established. Subsequently, the tools of the marketing controlling (incoming orders and turnover, marketing key performance indicators, reporting, marketing audit) are described.

  11. Realising local government visions for developing district heating: Experiences from a learning country

    International Nuclear Information System (INIS)

    Bush, Ruth E.; Bale, Catherine S.E.; Taylor, Peter G.

    2016-01-01

    District heating (DH) has an important role to play in enabling cities to transition to low-carbon heating. Although schemes are commonplace in some countries, in ‘learning countries’ where building-level technologies make up the majority of heating systems there are numerous barriers to introducing DH. Local governments are seen as key actors in helping to create a ‘shared vision’ for DH amongst stakeholders. This study uses interviews with stakeholders from a range of sectors in the UK (an example of a learning country) to examine the visions of local actors for developing DH and the types of national policy that would support local implementation of these visions. The analysis shows that in engaging with DH development local governments seek multiple types of value. Realising this value will most likely happen by taking a long-term, planned approach to development. In contrast, national government policy is geared towards techno-economic criteria and may lead to only a minority of potential sites being developed, without realisation of wider social or environmental benefits aligned to local visions. The work highlights the importance of local strategic planning, enabled by aligned national policy, in realising the full economic, environmental and social benefits of DH. - Highlights: • Local governments are key to the development of district heating (DH). • Local government-led visions of DH seek to deliver complex value. • In the UK development is led by funding and commercial factors and is not strategic. • To enable DH, national policy must align with the vision of local actors. • Social and environmental criteria must be incorporated in decision-making.

  12. Primary energy and the competitiveness of district heating. Final report; Primaeaerienergia ja kaukolaemmoen kilpailukyky. Loppuraportti

    Energy Technology Data Exchange (ETDEWEB)

    Broeckl, M.; Pesola, A.; Vanhanen, J.

    2010-09-15

    Primary energy is an important topic when discussing the most efficient ways to heat buildings. It has been suggested that in the new building codes the energy consumption of buildings should be evaluated based on either their primary energy consumption or the emission of greenhouse gases. This study has an objective to analyze how the district heating primary energy coefficient, which is possibly going to be used in the new building codes, can be defined with different methods. The study also has an objective to evaluate how the competitiveness of district heating is influenced, if the future building codes are based on different values of primary energy coefficients for electricity, heating fuels and district heating. The weighting of the consumption of different energy forms in the building codes has a great deal of influence on the competitiveness of various energy forms. The way in which energy coefficients are defined is important for the competitiveness of district heating solutions when comparing it to other forms of heating, such as electricity based heating systems, e.g. various heat pumps. Similarly important issue is how the energy-coefficients of wood based heating forms, prevalent especially in the countryside, are defined. On the other hand, the definition of primary coefficients is only one aspect which influences the competitiveness of different heating solutions. The investment costs required, operating costs as well as ease of use play an important role in the choice of heating solutions. It has to be noted that the primary energy coefficients for district heating and electricity are a function of time and place. Renewable fuels also have a big impact on the energy coefficients especially when used for combined heat and electricity production. This means that in reality district heating can't be described completely unambiguously with a standard coefficient. There are in fact several ways to define and calculate primary energy coefficients

  13. The Innovative Concept of Cold District Heating Networks: A Literature Review

    Directory of Open Access Journals (Sweden)

    Marco Pellegrini

    2018-01-01

    Full Text Available The development of sustainable and innovative solutions for the production and supply of energy at district level is nowadays one of the main technical challenges. In the past, district heating and cooling networks aimed to achieve greater energy efficiency through the centralization of the energy production process but with relevant losses related to heat transport. Moving towards a higher share of renewables and lower demand of primary energy requires redesign of the energy district networks. The novel concept of cold district heating networks aims to combine the advantages of a centralized energy distribution system with low heat losses in energy supply. This combined effect is achieved through the centralized supply of water at relatively low temperatures (in the range 10–25 °C, which is then heated up by decentralized heat pumps. Moreover, cold district heating networks are also very suitable for cooling delivery, since cold water supplying can be directly used for cooling purposes (i.e., free cooling or to feed decentralized chillers with very high energy efficiency ratio. This paper provides a preliminary literature review of existing cold district heating networks and then qualitatively analyses benefits and drawbacks in comparison with the alternatives currently used to produce heat and cold at district level, including the evaluation of major barriers to its further development.

  14. Optimal usage of low temperature heat sources to supply district heating by heat pumps

    DEFF Research Database (Denmark)

    Pieper, Henrik; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2017-01-01

    . Groundwater, seawater and air heat sources were compared with each other as well as to a scenario consisting of a combination of these heat sources. In addition, base load and peak load units were included. Characteristic parameters were the coefficient of performance, the number of full load hours...... and the covered demand of each heat source as well as required peak unit capacity. The results showed that heat pumps using different heat sources yield better performance than a heat pump based on a single one. The performance was influenced by the composition of the different heat sources. It was found that 78......% groundwater, 22% seawater and 0% air resulted in highest COP of 3.33 for the given heat demand. Furthermore, the implementation of rule based short term storage made peak units redundant. The variation in base load capacity showed that heat pumps utilizing the analyzed heat sources could perform very...

  15. High-Temperature Reactor For Power Generation and District Heating

    International Nuclear Information System (INIS)

    Herzberger, Karlheinz

    1987-01-01

    The multinational BBC Brown Brave Group, which has its head-quarters in Baden/Switzerland, was founded in 1891. Its German company is Brown, Brave and CIEs AGM, Mannheim. The field of operation covers wide areas of electrical engineering: These includes mainly the manufacture of installations and equipment for the generation, conversion, distribution and utilization of electric power, with special emphasis on the capital goods sector. BBC erects turnkey power plants and manufactures electrical equipment for industrial plants and urban transport and main line trains. Also of major importance are standard electrical products such as motors, switches, cables, semiconductor devices as well as measuring and control equipment. In the field of nuclear power BBC is engaged in particular in the development and construction of high-temperature reactors for the generation of electric power and process heat. The following presentation gives a short view on the milestones of the HTR development achieved in 1987

  16. Large scale solar district heating. Evaluation, modelling and designing

    Energy Technology Data Exchange (ETDEWEB)

    Heller, A.

    2000-07-01

    The main objective of the research was to evaluate large-scale solar heating connected to district heating (CSDHP), to build up a simulation tool and to demonstrate the application of the tool for design studies and on a local energy planning case. The evaluation of the central solar heating technology is based on measurements on the case plant in Marstal, Denmark, and on published and unpublished data for other, mainly Danish, CSDHP plants. Evaluations on the thermal, economical and environmental performances are reported, based on the experiences from the last decade. The measurements from the Marstal case are analysed, experiences extracted and minor improvements to the plant design proposed. For the detailed designing and energy planning of CSDHPs, a computer simulation model is developed and validated on the measurements from the Marstal case. The final model is then generalised to a 'generic' model for CSDHPs in general. The meteorological reference data, Danish Reference Year, is applied to find the mean performance for the plant designs. To find the expectable variety of the thermal performance of such plants, a method is proposed where data from a year with poor solar irradiation and a year with strong solar irradiation are applied. Equipped with a simulation tool design studies are carried out spreading from parameter analysis over energy planning for a new settlement to a proposal for the combination of plane solar collectors with high performance solar collectors, exemplified by a trough solar collector. The methodology of utilising computer simulation proved to be a cheap and relevant tool in the design of future solar heating plants. The thesis also exposed the demand for developing computer models for the more advanced solar collector designs and especially for the control operation of CSHPs. In the final chapter the CSHP technology is put into perspective with respect to other possible technologies to find the relevance of the application

  17. Towards a Future of District Heating Systems with Low-Temperature Operation together with Non-Fossil Fuel Heat Sources

    DEFF Research Database (Denmark)

    Tol, Hakan; Dinçer, Ibrahim; Svendsen, Svend

    2012-01-01

    This study focused on investigation of non-fossil fuel heat sources to be supplied to low-energy district heating systems operating in low temperature such as 55 C and 25 C in terms of, respectively, supply and return. Vast variety of heat sources classed in categories such as fossil fuel...

  18. Road map for district heating. The role of district heating in the energy system. Main report; Denmark; Roadmap for fjernvarmen. Fjernvarmens rolle i energisystemet. Hovedrapport

    Energy Technology Data Exchange (ETDEWEB)

    Hofmeister, M.; Aabye Moeller, A.; Eggert, A.; Bjerregaard, M. (Fjernvarmens Udviklingscenter, AArhus (Denmark)); Dyrelund, A. (Ramboell, Koebenhavn (Denmark)); OErsted Pedersen, H. (Ea Energianalyse, Koebenhavn (Denmark)); Lund, H. (Aalborg Univ., Aalborg (Denmark))

    2011-07-01

    In the recent years many studies of how Denmark can be fossil free by 2050 it is agreed that district heating will play a crucial role. District heating is an important factor of phasing out fossil fuels in an energy-and cost-effective way. But the future energy supply without fossil fuels poses new requirements for district heating. In the future, district heating shall provide energy for low-energy houses, have low distribution losses and use a variety of heat sources such as geothermal, solar, waste, surplus heat, CHP and various biomass con-version processes. In addition, it must all be done in an energy efficient way and in an active interaction with production of electricity and electricity consumption and, through integration of electricity from wind, solar and wave power. Low temperature, use of heat pumps and the interaction with electricity and biomass will be keywords. It is not only in Denmark we will need an active development of future technologies and systems. Large parts of Europe and many other parts of the world need the same development, and today Denmark has a significant export in the market - an export that has risen sharply, despite the recent economic recession. There is thus a double need to actively promote the development of future district heating technologies. We will partly need the technology development to realize the goal of a fossil free society and secondly because it is necessary to maintain and expand the export. This report contains a number of proposals for concrete actions - a roadmap for the development of district heating. The project is anchored at the District Energy Development Center that will work for an implementation of the concrete project ideas after the project completion. There is a need to increase the activity level for development of district heating. There is therefore a need to ensure financing of this development. We suggest that this can be done by creating an opportunity for a more sustained funding, for

  19. Road map for district heating. The role of district heating in the energy system. Summary report; Denmark; Roadmap for fjernvarmen. Fjernvarmens rolle i energisystemet. Resumerapport

    Energy Technology Data Exchange (ETDEWEB)

    Hofmeister, M.; Aabye Moeller, A.; Eggert, A.; Bjerregaard, M. (Fjernvarmens Udviklingscenter, AArhus (Denmark)); Dyrelund, A. (Ramboell, Koebenhavn (Denmark)); OErsted Pedersen, H. (Ea Energianalyse, Koebenhavn (Denmark)); Lund, H. (Aalborg Univ., Aalborg (Denmark))

    2011-07-01

    In the recent years many studies of how Denmark can be fossil free by 2050 it is agreed that district heating will play a crucial role. District heating is an important factor of phasing out fossil fuels in an energy-and cost-effective way. But the future energy supply without fossil fuels poses new requirements for district heating. In the future, district heating shall provide energy for low-energy houses, have low distribution losses and use a variety of heat sources such as geothermal, solar, waste, surplus heat, CHP and various biomass con-version processes. In addition, it must all be done in an energy efficient way and in an active interaction with production of electricity and electricity consumption and, through integration of electricity from wind, solar and wave power. Low temperature, use of heat pumps and the interaction with electricity and biomass will be keywords. It is not only in Denmark we will need an active development of future technologies and systems. Large parts of Europe and many other parts of the world need the same development, and today Denmark has a significant export in the market - an export that has risen sharply, despite the recent economic recession. There is thus a double need to actively promote the development of future district heating technologies. We will partly need the technology development to realize the goal of a fossil free society and secondly because it is necessary to maintain and expand the export. This report contains a number of proposals for concrete actions - a roadmap for the development of district heating. The project is anchored at the District Energy Development Center that will work for an implementation of the concrete project ideas after the project completion. There is a need to increase the activity level for development of district heating. There is therefore a need to ensure financing of this development. We suggest that this can be done by creating an opportunity for a more sustained funding, for

  20. Opening of the markets increases the risks of district heating business

    International Nuclear Information System (INIS)

    Silvennoinen, A.

    2001-01-01

    Maintenance of the technical operation conditions of district heating is the main requirement of community to the district heating business. Infrastructure of district heating, including the heat generation and distribution plants, equipment and devices, requires relatively large investments. Total process from fuel purchase to heat delivery does not occur in a closed limited area, but it penetrates the total market area (heat distribution network) and even larger via fuel purchase and transport. E.g. the fuels are combustible and might explode. Oil-spills into the environment may have catastrophic effects. Large leakage of hot district heating water is both environmentally hazardous and forms also a health hazard, and they stop the delivery of district heat. Dominant position on the markets is also followed closely by the authorities. On the other hand competition with other heating forms require efficient operation. The author reviews in the article the basics of risk management, and especially in the district heating business. The risk management process is discussed in the risk analysis and determination of the significance of the risks, the effects of realization of the risks, planning of the measures to be taken to avoid risks, and preparations against the risks

  1. Istra district heating system. Master plan and feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-09-01

    This report presents the results of the Feasibility Study of options for improving the efficiency and operating economy of Istra Large-Scale Demonstration Project includes all areas of the town of Istra. However, the Feasibility Study is confined to the five largest adjoining boilers plant areas within the borders of Istra town. The study was conducted from 1999 to 2001 and was based on information collected during this period. The city administration and the district heating company in Istra provided the data. The company RDIEE, Russian Danish Institute for Energy Efficiency, in Istra collected and processed the data under the conduction of Carl Bro a/s in Denmark. The main objectives of the study are to provide the Istra DHC with a number of options for future development of the district heating system based on technical/financial analyses and presenting the best possibilities for improved comfort, operation and business development. More concretely, one or more system improvement scenarios, which can be implemented in the near future as a first step of the recommended medium-term to long-term development, are identified. Another important objective has been to train the specialists of RDIEE in the feasibility study process and to transfer know-how, skills and tools. The model used for this study is adapted to the features and the special problems to be addressed in relation to the Istra district heating system. RDIEE and Istra DHC are thereby provided with a useful tool which may be used for continued study and development after the first phase project has been completed. As usual in the case of input/output models the quality of the results depends very much on the quality of input data. The present report is exclusively based on the consultant's understanding of the provided information. The results and the underlying inputs should be carefully considered before any final decision concerning implementation is taken. Verification of assumptions should also

  2. Inventory of future power and heat production technologies. Partial report Boilers/Combustion/Steam cycle for district heating and cogeneration

    International Nuclear Information System (INIS)

    Schuster, Robert

    2008-12-01

    The energy market of today is turbulent and it is quite clear that big changes in the consumption pattern are going to occur, due to the expansion in Asia and the expected Climate Change. The EU has, as a first step, stated in a directive that the consumption of renewable energy in the heat and power sector should be increased to 20 % and in the transportation sector to 10 % by the year 2020, a target which is high above current levels in most of the EU countries. It is reasonable to believe the European demand of renewable energy will create a shortage of biomass and that the development and use of technology for energy production will therefore not only depend on what is technically possible. One scenario is that biomass is mainly used for the markets that have very few alternatives, such as the transportation sector and small scale CHP units. We have today a relatively high electrical consumption through a stable grid and district heating nets in almost all densely populated areas. Large high efficiency power plants combined with heat pump technology will probably prevent any significant expansion of the district heating nets. A third major net for gas distribution seems not to be a feasible solution. Local nets for production of biogas from wet waste for different purposes, including EvGT units with 55% efficiency may however be good solution for some areas. There are a number of cycles and technical solutions to increase the electrical efficiency which could be applied also on smaller plants. The total efficiency will however not increase, only the el/heat ratio and it is not obvious that the higher investment cost for indirect cycles, bottom cycles or extreme steam data in combination with the risk of lower availability is a feasible solution. Especially waste to energy plants, with their need of high utilisation time, are sensitive to long production interruptions. The existing heat sinks in Sweden will however be efficiently used for electrical production

  3. Comparison of Low-temperature District Heating Concepts in a Long-Term Energy System Perspective

    DEFF Research Database (Denmark)

    Lund, Rasmus Søgaard; Østergaard, Dorte Skaarup; Yang, Xiaochen

    2017-01-01

    District heating systems are important components in an energy efficient heat supply. With increasing amounts of renewable energy, the foundation for district heating is changing and the approach to its planning will have to change. Reduced temperatures of district heating are proposed...... as a solution to adapt it to future renewable energy systems. This study compares three alternative concepts for district heating temperature level: Low temperature (55/25 oC), Ultra-low temperature with electric boosting (45/25 oC), and Ultra-low temperature with heat pump boosting (35/20 oC) taking...... into account the grid losses, production efficiencies and building requirements. The scenarios are modelled and analysed in the analysis tool EnergyPLAN and compared on primary energy supply and socioeconomic costs. The results show that the low temperature solution (55/25 oC) has the lowest costs, reducing...

  4. Environmental analysis of a potential district heating network powered by a large-scale cogeneration plant.

    Science.gov (United States)

    Ravina, Marco; Panepinto, Deborah; Zanetti, Maria Chiara; Genon, Giuseppe

    2017-05-01

    Among the solutions for the achievement of environmental sustainability in the energy sector, district heating (DH) with combined heat and power (CHP) systems is increasingly being used. The Italian city of Turin is in a leading position in this field, having one of the largest DH networks in Europe. The aim of this work is the analysis of a further development of the network, addressed to reduce the presence of pollutants in a city that has long been subject to high concentration levels. The environmental compatibility of this intervention, especially in terms of nitrogen oxides (NO x ) and particulate matter (PM) emissions, is evaluated. The pollutants dispersion is estimated using the CALPUFF model. The forecasting scenario is created firstly by simulating the energy production of the main generation plants in response to the estimated heat demand, and secondly by investigating the amount and the dispersion of pollutants removed due to the elimination of the centralized residential heaters. The results show a future reduction in ground level average NO x concentration ranging between 0.2 and 4 μg/m 3 . The concentration of PM remains almost unchanged. Measures are then taken to lower the uncertainty in the simulation scenarios. This study provides important information on the effects of a change of the energy configuration on air quality in an urban area. The proposed methodological approach is comprehensive and repeatable.

  5. Financial cost-benefit analysis of investment possibilities in district heating system on wood residues

    Directory of Open Access Journals (Sweden)

    Stošić Ivan

    2017-01-01

    Full Text Available The purpose of this research is to provide feasibility analysis of a long-term sustainable development concept for district heating based on wood residues. In this paper, the experimental study has been conducted starting from the data collected by field researches in municipality of Trstenik (town in Serbia with district heating system currently based on heavy fuel oil and lignite. Using the method of Financial Cost-Benefit Analysis, this study evaluates financial efficiency of investment in district heating plant based on wood residues and energy savings in district heating system. Findings show that such investment could be profitable from the financial point of view: Net Present Value of investment is positive, Financial Rate of Return is high (30.69%, and the pay-back period is relatively favourable (7 years. Moreover, the presented SWOT indicates that there are realistic prospects of implementation of district heating based on wood residues. However, this does not mean everything will go smoothly and easily, keeping in mind a number of challenges that each new concept of district heating contains immanently. Nevertheless, the results of this research could provide useful inputs for the decision makers when selecting appropriate models for improving performance of municipal district heating systems.

  6. The role of district heating in the future Danish energy system

    DEFF Research Database (Denmark)

    Münster, Marie; Morthorst, Poul Erik; Larsen, Helge V.

    2012-01-01

    is used as a case as the country has a high share of district heating and produces 20% of the electricity with wind power. The analyses are carried out using the electricity market model Balmorel, which facilitates cost optimization of operation and investments in energy production plants as well......In the EU and in Denmark, the aim is to reduce dependence on fossil fuels and to use energy more efficiently. District heating and combined heat and power have significant potential with regard to achieving this aim. New technologies may make individual solutions such as electric heating, heat...... as electricity transmission. To be able to perform the analysis an extension of the model is developed, where it is also possible to optimize between investments in individual heating plants or in expansion of the district heating networks, depending on investment costs, energy density of the potential areas...

  7. District heating as the infrastructure for competition among fuels and technologies

    DEFF Research Database (Denmark)

    Grohnheit, Poul Erik; Mortensen, Bent Ole Gram

    2016-01-01

    for increased energy efficiency. Additional technologies suitable for small-scale networks are heat pumps, solar panels and local biomass in the form of straw or biogas. For large-scale urban networks, incineration of urban waste and geothermal heat are key technologies. With heat storages district heating...... and cogeneration but limited support for the development and expansion of the district heating infrastructure. It was partly based on a contribution to the Shared Analysis Project for the European Commission Directorate-General for Energy, concerning the penetration of combined heat and power (CHP), energy saving......, such as the legal and institutional framework. This includes the experience with market places for electricity trade on an hourly basis over the last two decades. Improved modelling tools and modelling experience will add to the development and performance of district heating systems. Finally, we summarise...

  8. Design and System Analysis of Quad-Generation Plant Based on Biomass Gasification Integrated with District Heating

    DEFF Research Database (Denmark)

    Rudra, Souman

    This thesis presents the development of energy system for simulation, techno-economic optimization and design of a quad-generation energy system based on biomass gasification. An efficient way of reducing CO2 emission from the environment is by increasing the use of biomass in the energy sector...... alternative by upgrading existing district heating plant. It provides a generic modeling framework to design flexible energy system in near future. These frameworks address the three main issues arising in the planning and designing of energy system: a) socio impact at both planning and proses design level; b...

  9. The demand function for residential heat through district heating system and its consumption benefits in Korea

    International Nuclear Information System (INIS)

    Lim, Seul-Ye; Kim, Hyo-Jin; Yoo, Seung-Hoon

    2016-01-01

    The demand for residential heat (RH) through a district heating system (DHS) has been and will be expanded in Korea due to its better performance in energy efficiency and the abatement of greenhouse gas emissions than decentralized boilers. The purposes of this paper are two-fold. The first is to obtain the demand function for DHS-based RH in Korea and investigate the price and income elasticities of the demand employing the quarterly data covering the period 1988–2013. The short-run price and income elasticities are estimated as −0.700 and 0.918, respectively. Moreover, the long-run elasticities are −1.253 and 1.642, respectively. The second purpose is to measure the consumption benefits of DHS-based-RH employing the economic theory that they are the sum of the actual payment and consumer surplus for the consumption. Considering that the average price and estimated consumer surplus of the DHS-based RH use in 2013 are computed to be KRW 87,870 (USD 84.1) and KRW 62,764 (USD 60.1) per Gcal, the consumption benefits of the DHS-based RH are calculated to be KRW 150,634 (USD 144.2) per Gcal. This information can be beneficially utilized to conduct an economic feasibility study for a new DHS project related to RH supply. - Highlights: • Demand for residential heat (RH) from district heating system (DHS) is expanding. • We estimate the demand function for and consumption benefits of DHS-based RH. • Short-run price and income elasticities are −0.700 and 0.918, respectively. • Long-run price and income elasticities are −1.253 and 1.642, respectively. • Consumption benefits of DHS-based RH are KRW 150,634 (USD 144.2) per Gcal.

  10. Energetic and Exergetic Analysis of Low and Medium Temperature District Heating Network Integration

    DEFF Research Database (Denmark)

    Li, Hongwei; Svendsen, Svend

    In this paper, energetic and exergetic approaches were applied to an exemplary low temperature district heating (LTDH) network with supply/return water temperature at 55oC/25 oC. The small LTDH network is annexed to a large medium temperature district heating (MTDH) network. The LTDH network can ...... will reduce the amount of water supply from the MTDH network and improve the system energy conversion efficiency. Through the simulation, the system energetic and exergetic efficiencies based on the two network integration approaches were calculated and evaluated.......In this paper, energetic and exergetic approaches were applied to an exemplary low temperature district heating (LTDH) network with supply/return water temperature at 55oC/25 oC. The small LTDH network is annexed to a large medium temperature district heating (MTDH) network. The LTDH network can...

  11. District heating networks: tools for local organizations; Les reseaux de chaleur: outils des collectivites locales

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-07-01

    In France, about 250 cities are equipped with district heating networks which contribute to the improvement of the energy mastery and of the air quality, to the reduction of the energy dependence and of the petroleum bill, to a better management of wastes, and to the local development (activity and employment). After a recall of the history of the development of district heating in France, this report describes the advantages of district heating in the national and local policies of: energy mastery, development of renewable energy sources and cogeneration systems, improvement of air quality, and economical and social development of urban areas. Two remarkable examples of district heating networks (Metz and Vitry le Francois) are presented in appendix. (J.S.)

  12. Environmental Assessment for the Bison School District Heating Plant Project, Institutional Conservation Program (ICP)

    International Nuclear Information System (INIS)

    1995-01-01

    This environmental assessment analyzes the environmental impacts of replacing the Bison, South Dakota School District's elementary school and high school heating system consisting of oil-fired boilers and supporting control system and piping

  13. Heat transport analysis in a district heating and snow melting system in Sapporo and Ishikari, Hokkaido applying waste heat from GTHTR300

    International Nuclear Information System (INIS)

    Kasahara, Seiji; Kamiji, Yu; Terada, Atsuhiko; Yan Xing; Inagaki, Yoshiyuki; Murata, Tetsuya; Mori, Michitsugu

    2015-01-01

    A district heating and snow melting system utilizing waste heat from Gas Turbine High temperature Gas Reactor of 300 MW e (GTHTR300), a heat-electricity cogeneration design of high temperature gas-cooled reactor, was analyzed. Application areas are set in Sapporo and Ishikari, the heavy snowfall cities in Northern Japan. The heat transport analyses are carried out by modeling the components in the system; pipelines of the secondary water loops between GTHTR300s and heat demand district and heat exchangers to transport the heat from the secondary water loops to the tertiary loops in the district. Double pipe for the secondary loops are advantageous for less heat loss and smaller excavation area. On the other hand, these pipes has disadvantage of more electricity consumption for pumping. Most of the heat demand in the month of maximum requirement can be supplied by 2 GTHTR300s and delivered by 9 secondary loops and around 5000 heat exchangers. Closer location of GTHTR300 site to the heat demand district is largely advantageous economically. Less decrease of the distance from 40 km to 20 km made the heat loss half and cost of the heat transfer system 22% smaller. (author)

  14. District Heating Network Design and Configuration Optimization with Genetic Algorithm

    DEFF Research Database (Denmark)

    Li, Hongwei; Svendsen, Svend

    2011-01-01

    the heating plant location is allowed to vary. The connection between the heat generation plant and the end users can be represented with mixed integer and the pipe friction and heat loss formulations are non-linear. In order to find the optimal DH distribution pipeline configuration, the genetic algorithm...... by multi factors as the consumer heating load, the distance between the heating plant to the consumer, the design criteria regarding pressure and temperature limitation, as well as the corresponding network heat loss....

  15. Performance of low-temperature district heating for low-energy houses

    DEFF Research Database (Denmark)

    Brand, Marek; Dalla Rosa, Alessandro; Svendsen, Svend

    2010-01-01

    houses, which was previously developed and reported in the project “Development and demonstration of low-energy district heating for low energy housing” [EFP, 2007]. Two different concepts of low energy district heating substations are tested, and measurements of their performance aim to document...... that LEDH is a proper solution for sustainable heating systems and answer the question which concept of used substations is more favourable to be used in detached low energy houses. The preliminary results show that LEDH can provide low energy buildings with space heating and domestic hot water (DHW...

  16. Risk assessment of new pricing strategies in the district heating market

    International Nuclear Information System (INIS)

    Bjoerkqvist, Olof; Idefeldt, Jim; Larsson, Aron

    2010-01-01

    The price structure of district heating has been no major scientific issue for the last decades in energy-related research. However, today trends in district heating pricing tend to move towards a more customer-oriented approach with predetermined prices under a longer periods, leading to a more complex price structure. If a district heating supplier offers district heating with predetermined prices in order to compete with similar electricity offers, the financial risk of the new price structure is significantly higher than the risk of an ordinary variable cost offer based on short-run marginal cost. In contrary to an electricity seller, the district heating company cannot transfer all of the risk of predetermined prices to the financial market, instead the company is thrown upon its own ability to handle the risk by, e.g., hedging its own energy purchase. However, all uncertainties cannot be coped with in this manner. Thus, there is a need for a methodology that can be used to estimate the financial risk of different price structures and to value different opportunities to reduce the risk. In this article, we propose a methodology, implemented in prototype software, to evaluate the risk associated with new price structures in district heating.

  17. Process evaluation of communitisation programme in public sector health facilities, Mokokchung district, Nagaland, 2015

    Directory of Open Access Journals (Sweden)

    Aonungdok Tushi

    2017-01-01

    Full Text Available Background: Public sector health facilities were poorly managed due to a history of conflict in Nagaland, India. Government of Nagaland introduced “Nagaland Communitisation of Public Institutions and Services Act” in 2002. Main objectives of the evaluation were to review the functioning of Health Center Managing Committees (HCMCs, deliver health services in the institutions managed by HCMC, identify strengths as well as challenges perceived by HCMC members in the rural areas of Mokokchung district, Nagaland. Materials and Methods: The evaluation was made using input, process and output indicators. A doctor, the HCMC Chairman and one member from each of the three community health centers (CHC and four primary health centers (PHC were surveyed using a semi-structured questionnaire and an in-depth interview guide. Proportions for quantitative data were computed and key themes from the same were identified. Results: Overall; the infrastructure, equipment and outpatient/inpatient service availability was satisfactory. There was a lack of funds and shortage of doctors, drugs as well as laboratory facilities. HCMCs were in place and carried out administrative activities. HCMCs felt ownership, mobilized community contributions and managed human resources. HCMC members had inadequate funds for their transport and training. They faced challenges in service delivery due to political interference and lack of adequate human, material, financial resources. Conclusions: Communitisation program was operational in the district. HCMC members felt the ownership of health facilities. Administrative, political support and adequate funds from the government are needed for effective functioning of HCMCs and optimal service delivery in public sector facilities.

  18. Performance Analysis of a Hybrid District Heating System: a Case Study of a Small Town in Croatia

    Directory of Open Access Journals (Sweden)

    Robert Mikulandric

    2015-09-01

    Full Text Available Hybridisation of district heating systems can contribute to more efficient heat generation through cogeneration power plants or through the share increase of renewable energy sources in total energy consumption while reducing negative aspects of particular energy source utilisation. In this work, the performance of a hybrid district energy system for a small town in Croatia has been analysed. Mathematical model for process analysis and optimisation algorithm for optimal system configuration has been developed and described. The main goal of the system optimisation is to reduce heat production costs. Several energy sources for heat production have been considered in 8 different simulation cases. Simulation results show that the heat production costs could be reduced with introduction of different energy systems into an existing district heating system. Renewable energy based district heating systems could contribute to heat production costs decrease in district heating systems up to 30% in comparison with highly efficient heat production technologies based on conventional fuels.

  19. Improving urban district heating systems and assessing the efficiency of the energy usage therein

    Science.gov (United States)

    Orlov, M. E.; Sharapov, V. I.

    2017-11-01

    The report describes issues in connection with improving urban district heating systems from combined heat power plants (CHPs), to propose the ways for improving the reliability and the efficiency of the energy usage (often referred to as “energy efficiency”) in such systems. The main direction of such urban district heating systems improvement suggests transition to combined heating systems that include structural elements of both centralized and decentralized systems. Such systems provide the basic part of thermal power via highly efficient methods for extracting thermal power plants turbines steam, while peak loads are covered by decentralized peak thermal power sources to be mounted at consumers’ locations, with the peak sources being also reserve thermal power sources. The methodology was developed for assessing energy efficiency of the combined district heating systems, implemented as a computer software product capable of comparatively calculating saving on reference fuel for the system.

  20. Modelling temperature dynamics of a district heating system in Naestved, Denmark-A case study

    International Nuclear Information System (INIS)

    Gabrielaitiene, Irina; Bohm, Benny; Sunden, Bengt

    2007-01-01

    Modelling the temperature dynamics of a district heating system is typically validated for a single pipe or a system with limited information about dynamic consumer behaviour. In the present work, time dependent consumer data from the Naestved district heating system was used to investigate the ability of modelling tools to represent the temperature profile distortion throughout an entire heating system network. The Naestved district heating subsystem was modelled by two approaches (the node method developed at the Technical University of Denmark and the software TERMIS), and these modelling results were compared with measured data. The results indicate that the discrepancies between the predicted and measured temperatures are pronounced for consumers located in pipelines at distant pipelines containing numerous bends and fittings. Additionally, it was found that representing the consumer behaviour on an annual average basis introduced a deviation between the predicted and the measured return temperatures at the heat source

  1. Building an eco-effective district heating management system in a city

    Directory of Open Access Journals (Sweden)

    Gitelman Leonid

    2016-01-01

    Full Text Available The goal of making the urban environment safer amid increasing human impact adds to the importance of district heating management. The article outlines the results of a study into the problem of improving the urban environment by implementing two innovative solutions. Technological innovations imply the introduction of modern sustainable tools of reducing emissions in district heating networks, one of them being the combination of district heating and combined heat and power plants (a case study of Turin. Organizational innovations are built upon the management of demand for thermal energy that makes it possible to reduce investment in new construction and to optimize the architecture of heat load schedules for the purpose of alleviating energy and environmental pressure on the city. The authors propose formats and areas of demand side management for thermal energy and methods of offering economic incentives to program participants.

  2. Regional Energy Planning Tool for Renewable Integrated Low-Energy District Heating Systems

    DEFF Research Database (Denmark)

    Tol, Hakan; Dincer, Ibrahim; Svendsen, Svend

    2013-01-01

    Low-energy district heating systems, operating at low temperature of 55 °C as supply and 25°C as return, can be the energy solution as being the prevailing heating infrastructure in urban areas, considering future energy schemesaiming at increased exploitation of renewable energy sources together...... with low-energy houses in focus with intensified energy efficiency measures. Employing low-temperature operation allows the ease to exploit not only any type of heat source but also low-grade sources, i.e., renewable and industrial waste heat, which would otherwise be lost. In this chapter, a regional...... energy planning tool is described considered with various energy conversion systems based on renewable energy sources to be supplied to an integrated energy infrastructure involving a low-energy district heating, a district cooling, and an electricity grid. The developed tool is performed for two case...

  3. Optimal phasing of district heating network investments using multi-stage stochastic programming

    Directory of Open Access Journals (Sweden)

    Romain Stephane Claude Lambert

    2016-06-01

    Full Text Available Most design optimisation studies for district heating systems have focused on the optimal sizing of network assets and on the location of production units. However, the strategic value of the flexibility in phasing of the inherently modular heat networks, which is an important aspect in many feasibility studies for district heating schemes in the UK, is almost always neglected in the scientific literature. This paper considers the sequential problem faced by a decision-maker in the phasing of long-term investments into district heating networks and their expansions. The problem is formulated as a multi-stage stochastic programme to determine the annual capital expenditure that maximises the expected net present value of the project. The optimisation approach is illustrated by applying it to the hypothetical case of the UK’s Marston Vale eco town. It was found that the approach is capable of simulating the optimal growth of a network, from both a single heat source or separate islands of growth, as well as the optimal marginal expansion of an existing district heating network. The proposed approach can be used by decision makers as a framework to determine both the optimal phasing and extension of district heating networks and can be adapted simply to various, more complex real-life situations by introducing additional constraints and parameters. The versatility of the base formulation also makes it a powerful approach regardless of the size of the network and also potentially applicable to cooling networks.

  4. Techno-economic analysis of energy renovation measures for a district heated multi-family house

    International Nuclear Information System (INIS)

    Gustafsson, Marcus; Gustafsson, Moa Swing; Myhren, Jonn Are; Bales, Chris; Holmberg, Sture

    2016-01-01

    Highlights: • Energy saving measures can be cost-effective as part of a planned renovation. • Primary energy consumption, non-renewable energy consumption and CO 2 emissions are assessed for different electricity mixes. • EAHP can be a cost-effective and environmentally beneficial complement to district heating. • EAHP has lower LCC and significantly shorter payback time than ventilation with heat recovery. • Low-temperature ventilation radiators improve the COP of the heat pump. - Abstract: Renovation of existing buildings is important in the work toward increased energy efficiency and reduced environmental impact. The present paper treats energy renovation measures for a Swedish district heated multi-family house, evaluated through dynamic simulation. Insulation of roof and façade, better insulating windows and flow-reducing water taps, in combination with different HVAC systems for recovery of heat from exhaust air, were assessed in terms of life cycle cost, discounted payback period, primary energy consumption, CO 2 emissions and non-renewable energy consumption. The HVAC systems were based on the existing district heating substation and included mechanical ventilation with heat recovery and different configurations of exhaust air heat pump. Compared to a renovation without energy saving measures, the combination of new windows, insulation, flow-reducing taps and an exhaust air a heat pump gave up to 24% lower life cycle cost. Adding insulation on roof and façade, the primary energy consumption was reduced by up to 58%, CO 2 emissions up to 65% and non-renewable energy consumption up to 56%. Ventilation with heat recovery also reduced the environmental impact but was not economically profitable in the studied cases. With a margin perspective on electricity consumption, the environmental impact of installing heat pumps or air heat recovery in district heated houses is increased. Low-temperature heating improved the seasonal performance factor of the

  5. District heating systems' control for cost effective and environmentally compatible operation

    International Nuclear Information System (INIS)

    Balati, J.

    1999-01-01

    District heating systems are being developed in accordance with the growing of large European cities. These systems are formed by enlarging networks of heat distribution from heat sources to heat consumers and, simultaneously, by gradually connecting newly built heat sources. District heating control consists in optimum control of the output of heat sources and in control of heat distribution and consumption. The aim of the paper is to inform about the works in the field of creating a mathematical-physical model of extensive hot water and steam supply circle network and heat sources for the purpose of creating unconventional control algorithms for the complex control of the technological sequence ''heat production distribution- consumption''. For the optimum control algorithms the artificial intelligence methods are also utilised. The aim of the complex access to the solution of new control algorithms will be to decrease the cost of the consumed heat unit and increase environmental protection. The function of the Extensive Heating System District Heating System (DHS) is to ensure permanently the economically justified requirements of heat supply for all consumers with minimum cost per heat supply unit and with enhanced level of environmental protection. The requirements of heat consumers have to be in harmony with the requirements of the maximum possible economy of the whole DHS when adhering to the required qualitative parameters of supplied energy. Therefore, it offers the application of optimised control methods as artificial intelligence methods for the control of the operational circle of DHS heat networks. It is obvious that a higher level of DHS control is required from the technological, economic and ecological point of view. (author)

  6. Comparison of Low-temperature District Heating Concepts in a Long-Term Energy System Perspective

    DEFF Research Database (Denmark)

    Lund, Rasmus Søgaard; Østergaard, Dorte Skaarup; Yang, Xiaochen

    2017-01-01

    District heating (DH) systems are important components in an energy efficient heat supply. With increasing amounts of renewable energy, the foundation for DH is changing and the approach to its planning will have to change. Reduced temperatures of DH are proposed as a solution to adapt it to futu...

  7. Effect of heat stress on six beef breeds in the Zastron district: The ...

    African Journals Online (AJOL)

    Effect of heat stress on six beef breeds in the Zastron district: The significance of breed, coat colour and coat type. L.A Foster, P.J Fourie, F.W.C Neser. Abstract. A study was done to determine which factors had the greatest influence on a heifer's susceptibility to heat stress. Parameters tested were breed, coat colour, coat ...

  8. The Sydvaerme project: District heating from the Barsebeck nuclear power plant

    International Nuclear Information System (INIS)

    Josefsson, L.

    1977-01-01

    The paper presents a summary report of a study on district heating from Barsebeck Nuclear Power Plant in Sweden, prepared cooperatively by the cities of Malmoe, Lund, Helsingborg, Landskrona and the electric power company Sydkraft. A future number 3 generating set at the Barsebeck nuclear power station could be designed for combined production of heat and electric power. The generating set could be completed after 1983, and could then supply about 65% of total district heating requirements. The first stage of the investigation includes a proposal for a technically feasible solution, sufficiently detailed to permit both technical and economic evaluation of the project. (author)

  9. Assessment of existing and prospective piping technology for district-heating applications

    Energy Technology Data Exchange (ETDEWEB)

    Oliker, I.

    1979-09-01

    Data on design features and operational experience of 40 hot water and steam district-heating networks with an overall heat capacity of 18,000 MWt have been collected, systematized, and analyzed. Piping networks located in Canada, Denmark, Finland, France, Italy, Japan, Netherlands, Sweden, USA, USSR, and West Germany have been analyzed and the data assembled. The data bank and analysis of the operational experience design features of hot water and steam district-heating networks are provided in Sections 2 and 3. In Section 4 the piping installation design is optimized in order to reduce costs wherever possible, without jeopardizing overall system efficiency, reliability or service life, and employing a mixture of typical US and European district-heating practices. The status of prospective non-metallic piping materials is presented in Section 5. The following materials have been investigated: fiberglass reinforced plastic, cross-linked polyethylene, polybutylene, prestressed concrete, polymer concrete, and asbestos-cement piping. (MCW)

  10. Transwaal - economic district heat from the Beznau nuclear power station

    International Nuclear Information System (INIS)

    Schatzmann, G.

    1986-01-01

    Initial study phases of the Transwaal project for distribution of heat from the Beznau nuclear power station via pipe lines to Aare and Limmat valley regions in Switzerland are presented. 500 MW heat availability through heat exchangers providing forward flow water temperature of 120 0 C, pipe line network and pumping station aspects, and the system energy flow diagram, are described. Considerations based on specific energy requirements in the year 2000 including alternative schemes showed economic viability. Investment and consumer costs and savings compared with oil and gas heating are discussed. Heat supply is guaranteed well into the 21st century and avoids environmental disadvantages. (H.V.H.)

  11. Cogeneration steam turbine plant for district heating of Berovo (Macedonia)

    International Nuclear Information System (INIS)

    Armenski, Slave; Dimitrov, Konstantin

    2000-01-01

    A plant for combined heat and electric power production, for central heating of the town Berovo (Macedonia) is proposed. The common reason to use a co-generation unit is the energy efficiency and a significant reduction of environmental pollution. A coal dust fraction from B rik' - Berovo coal mine is the main energy resource for cogeneration steam turbine plant. The heat consumption of town Berovo is analyzed and determined. Based on the energy consumption of a whole power plant, e. i. the plant for combined and simultaneous production of power is proposed. All necessary facilities of cogeneration plant is examined and determined. For proposed cogeneration steam turbine power plant for combined heat and electric production it is determined: heat and electric capacity of the plant, annually heat and electrical quantity production and annually coal consumption, the total investment of the plant, the price of both heat and electric energy as well as the pay back period. (Authors)

  12. Current and future prospects for heat recovery from waste in European district heating systems: A literature and data review

    International Nuclear Information System (INIS)

    Persson, Urban; Münster, Marie

    2016-01-01

    Municipal solid waste has seen increasing annual volumes for many decades in contemporary Europe and constitutes, if not properly managed, an environmental problem due to local pollution and greenhouse gas emissions. From an energy perspective, waste is also an alternative fuel for power and heat generation; energy recovery from waste represents an effective measure to reduce landfilling and avoid disposal emissions while simultaneously reducing the equivalent demand for primary energy supply. A key factor for obtaining the full synergetic benefits of this energy recovery is the presence of local heat distribution infrastructures, without which no large-scale recovery and utilisation of excess heat is possible. In this paper, which aims to estimate municipal solid waste volumes available for heat recovery in European district heating systems in 2030, a literature and data review is performed to establish and assess current and future EU (European Union) waste generation and management. Main conclusions are that more heat can be recovered from current Waste-to-Energy facilities operating at low average heat recovery efficiencies, that efficient incineration capacity is geographically concentrated, and that waste available for heat recovery in 2030 is equally determined by total generation volumes by this year as by future EU deployment levels of district heating. - Highlights: • European municipal solid waste time series data analysed from 1995 to 2012. • Review of modelling approaches to assess future European waste generation. • Weather corrected district heat data for EU Member States in 1995 and 2012. • Low average heat recovery efficiency in current European waste incineration. • Future heat recovery efficiencies as determinant as future generation volumes.

  13. Electricity supply, district heating and supply of natural and gasworks gas 2000

    International Nuclear Information System (INIS)

    2001-01-01

    Total domestic use of electricity (including transmission losses) was 146.7 TWh in 2000. This represents an increase of 2.4 per cent compared to 1999. Usage in the household sector fell by 1.8 per cent to 33.7 TWh (including second homes). In contrast, the industry sector (manufacturing industry, mining and quarrying) increased its usage by 3.1 per cent to 57.0 TWh. Deliveries of steam and hot water for district heating were 41.6 TWh, a decrease of 4.9 per cent compared to 1999. Total net production of electricity decreased in 1999 by 5.8 per cent compared to 1999 and amounted to 142.0 TWh. Hydroelectric production increased by 10.1 per cent to 78.0 TWh. The production of conventional thermal power also fell, by 6.0 per cent to 8.8 TWh. Nuclear power contributed 54.8 TWh, a decrease by 22 per cent compared to the previous year. Wind power, however, increased its production by 24.8 per cent to 447 GWh. Imports of electricity increased by 9.8 TWh to 18.3 TWh, but exports decreased by 2.3 TWh to 13.6 TWh. Total deliveries of natural gas to final consumers diminished somewhat in 2000 and amounted to 835 million m 3 . The mean price of natural gas fell by approximately 13 per cent compared to 1999. Deliveries of gas-works gas fell in 2000 by 0.4 million m 3 to 106 million m 3 . The mean price was about 3 per cent lower than in the preceding year

  14. Electricity supply, district heating and supply of natural and gasworks gas 1999

    International Nuclear Information System (INIS)

    2001-01-01

    Total domestic use of electricity (including transmission losses) was 143.3 TWh in 1999. This represents a decrease of 0.5 per cent compared to 1998. Usage in the household sector fell by 1.5 per cent to 34.3 TWh (including second homes). In contrast, the industry sector (manufacturing industry, mining and quarrying) increased its usage by 1.1 per cent to 55.3 TWh. Deliveries of steam and hot water for district heating were 43.7 TWh, unchanged compared to 1998. Total net production of electricity decreased in 1999 by 2.5 per cent compared to 1998 and amounted to 150.8 TWh. Hydroelectric production decreased by 4.0 per cent to 70.9 TWh. The production of conventional thermal power also fell, by 5.6 per cent to 9.4 TWh. Nuclear power contributed 70.2 TWh, almost the same as the previous year. Wind power, however, increased its production by 16.2 per cent to 358 GWh. Imports of electricity increased by 0.4 TWh to 8.5 TWh, but exports decreased by 0.9 TWh to 15.9 TWh. Total deliveries of natural gas to final consumers diminished somewhat in 1999 and amounted to 854 million m 3 (equivalent to 9226 GWh). Deliveries of natural gas substitutes (air/liquefied petroleum gas mix) decreased by 5 per cent to 26 million m 3 . The mean price of natural gas rose by approximately 6 per cent compared to 1998. Deliveries of gas-works gas fell in 1999 by 0.6 million m 3 to 109.2 million m 3 . The mean price was about 11 per cent higher than in the preceding year

  15. Mapping Extreme Heat Vulnerability and Health Outcomes to inform the District of Columbia's Climate Adaptation Plan

    Science.gov (United States)

    Declet-Barreto, J.; Wilhelmi, O.; Goggans, A.

    2016-12-01

    In this collaborative engagement, scientists are partnering with the District of Columbia (DC) to develop an extreme heat vulnerability assessment. To do so, we map socio-demographic and built environment indicators of extreme heat vulnerability in Census Tracts in DC neighborhoods. In order to provide information useful for DC public health and urban planning practitioners, we aggregate the indicators into an index of extreme heat vulnerability. We compare the index against heat-related call data from DC's 911 system to better understand the socio-spatial distribution of extreme heat-related health outcomes. Our assessment can help inform the District's Climate Adaptation Plan as well as increase public engagement in reducing vulnerability to extreme heat.

  16. Case Studies in Low-Energy District Heating Systems: Determination of Dimensioning Methods for Planning the Future Heating Infrastructure

    DEFF Research Database (Denmark)

    Tol, Hakan; Nielsen, Susanne Balslev; Svendsen, Svend

    The climate crisis and the new technological possibilities for building low energy buildings give the opportunity to improve the municipal heating systems. The heating demand will be less in the future and renewable energy has to be integrated in the design of district heating systems. The paper ...... settlement, located in Gladsaxe Municipality, Denmark. The technical results of the case studies also conclude with an outline of possible municipal planning of DH system with regard to climate and energy.......The climate crisis and the new technological possibilities for building low energy buildings give the opportunity to improve the municipal heating systems. The heating demand will be less in the future and renewable energy has to be integrated in the design of district heating systems. The paper...... suggests a plan for an energy efficient District Heating (DH) system with low operating temperatures, such as 55°C supply and 25°C return; connected to low-energy buildings. Different case studies referring to typical DH planning situations could show the rational basis for the integrated planning...

  17. District heating and cooling system for communities through power plant retrofit and distribution network. Final report, Phase I

    Energy Technology Data Exchange (ETDEWEB)

    1979-06-01

    The technical and economic feasibility of retrofitting thermal power plants in Minnesota to accommodate both heat and power generation for district heating was examined and is discussed. Three communities were identified as viable sites for co-generation district heating. (LCL)

  18. Dynamic equation-based thermo-hydraulic pipe model for district heating and cooling systems

    OpenAIRE

    van der Heijde, Bram; Fuchs, Marcus; Ribas Tugores, Carles; Schweiger, Gerald; Sartor, Kevin; Basciotti, Daniele; Müller, Dirk; Nytsch-Geusen, Christoph; Wetter, Michael; Helsen, Lieve

    2017-01-01

    Simulation and optimisation of district heating and cooling networks requires efficient and realistic models of the individual network elements in order to correctly represent heat losses or gains, temperature propagation and pressure drops. Due to more recent thermal networks incorporating meshing decentralised heat and cold sources, the system often has to deal with variable temperatures and mass flow rates, with flow reversal occurring more frequently. This paper presents the mathematical ...

  19. A study of a small nuclear power plant system for district heating

    International Nuclear Information System (INIS)

    Imamura, Mitsuru; Sato, Kotaro; Narabayashi, Tadashi; Shimazu, Yoichiro; Tsuji, Masashi

    2009-01-01

    We have studied nuclear power plant for district heating. Already some towns and villages in Hokkaido have requested small reactor for district heating. Using existing technology allows us to shorten development period and to keep a lid on development cost. We decided to develop new reactor based on 'MUTSU' reactor technology because 'MUTSU' had already proved its safety. And this reactor was boron free reactor. It allows plant system to reduce the chemical control system. And moderator temperature coefficient is deeply negative. It means to improve its operability and leads to dependability enhancement. We calculated burn-up calculation of erbium addition fuel. In the result, the core life became about 10 years. And we adapt the cassette type refueling during outagein in order to maintain nonproliferation. In the district heating system, a double heat exchanger system enables to response to load change in season. To obtain the acceptance of public, this system has a leak prevention system of radioactive materials to public. And road heating system of low grade heat utilization from turbine condenser leads to improve the heat utilization efficiency. We carried out performance evaluation test of district heating pipeline. Then the heat loss of pipeline is estimated at about 0.440degC/km. This result meets general condition, which is about 1degC/km. This small plant has passive safety system. It is natural cooling of containment vessel. In case of loss of coolant accident, decay heat can remove by natural convection air cooling after 6 hours. Decay heat within 6 hours can remove by evaporative heat transfer of pool on containment vessel. (author)

  20. A proposed water sector plan for the Dr Kenneth Kaunda District Municipality (Dr KKDM

    Directory of Open Access Journals (Sweden)

    M Diedericks

    2015-07-01

    Full Text Available The radical reform of potable water services provisioning by means of promulgation of the Water Services Act 108 of 1997 and the National Water Act 36 of 1998 in South Africa (SA started a process of addressing the imbalance which existed in how the national resource was distributed. Water is now recognised as a scarce resource that belongs to all the people of the country and consequently it should be managed in an integrated way for social and economic development including future growth (Fuggle and Rabie 2005:293; Riemann, Chimboza and Fubesi 2012:446. The provision of potable water by water services authorities (WSAs is an important basic service that faces a number of challenges such as the use of out-dated infrastructure and a lack of skilled and knowledgeable people that place overt pressure on demand for service delivery. It is against this background that the researchers have undertaken to investigate how a municipality which is forced to obtain its potable water supply from nearby surface- and groundwater catchments, can manage it in a more effective, efficient, equal, economic and sustainable manner by means of improved planning procedures to enhance co-operative governance and intergovernmental relations. A qualitative research design was used to conduct the study, which included a literature review, semi-structured interviews, non-probability data sampling and scientific analyses of responses. Furthermore, a case-study approach was followed by the researchers, with Dr Kenneth Kaunda District Municipality (Dr KKDM as the unit of analysis (the locus. The major research finding of the study included that a Water Sector Plan (WSP was lacking and non-existent in the Dr Kenneth Kaunda District Municipality (Dr KKDM and therefore water services delivery could not be coordinated effectively.

  1. The Development of a New District Heating Concept

    DEFF Research Database (Denmark)

    Dalla Rosa, Alessandro

    alternative and offers the opportunity to implement the use of RE and low-grade heat sources. The areas with linear heat density below 1.5 MWh/(m.yr) are not economically feasible with the current situation of the energy market in Canada, but could be considered for future network extensions together...... conditions with regard to the inlet temperature profile. The proposed integrated solution consisting of service pipe and heat exchanger unit with a booster pump satisfies the requirement for DHW supply within l0 seconds and achieves heat savings for 200 kWhth/yr with an additional electricity use...... on ground-source heat pumps. The network designs based on low-temperature operation are superior to the design based on lowflow operation. The total primary energy use in the most energy-efficient design is 14.3% lower than in standard networks and the distribution heat losses are halved. The results...

  2. Feasibility study for retrofitting biogas cogeneration systems to district heating in South Korea.

    Science.gov (United States)

    Chung, Mo; Park, Hwa-Choon

    2015-08-01

    A feasibility study was performed to assess the technical and economic merits of retrofitting biogas-based cogeneration systems to district heating networks. Three district heating plants were selected as candidates for accommodating heat recovery from nearby waste treatment stations, where a massive amount of biogas can be produced on a regular basis. The scenario involves constructing cogeneration systems in each waste treatment station and producing electricity and heat. The amounts of biogas production for each station are estimated based on the monthly treatment capacities surveyed over the most recent years. Heat produced by the cogeneration system is first consumed on site by the waste treatment system to keep the operating temperature at a proper level. If surplus heat is available, it will be transported to the nearest district heating plant. The year-round operation of the cogeneration system was simulated to estimate the electricity and heat production. We considered cost associated with the installation of the cogeneration system and piping as initial investments. Profits from selling electricity and recovering heat are counted as income, while costs associated with buying biogas are expenses. Simple payback periods of 2-10 years were projected under the current economic conditions of South Korea. We found that most of the proposed scenarios can contribute to both energy savings and environmental protection. © The Author(s) 2015.

  3. Testing, development and demonstration of large scale solar district heating systems

    DEFF Research Database (Denmark)

    Furbo, Simon; Fan, Jianhua; Perers, Bengt

    2015-01-01

    know how on solar heating plants and solar heating test technology have been transferred from Denmark to China, large solar heating systems have been promoted in China, test capabilities on solar collectors and large scale solar heating systems have been improved in China and Danish-Chinese cooperation......In 2013-2014 the project “Testing, development and demonstration of large scale solar district heating systems” was carried out within the Sino-Danish Renewable Energy Development Programme, the so called RED programme jointly developed by the Chinese and Danish governments. In the project Danish...

  4. The role of district heating in decarbonising the EU energy system and a comparison with existing strategies

    DEFF Research Database (Denmark)

    Connolly, David; Lund, Henrik; Mathiesen, Brian Vad

    2013-01-01

    are identified and then, the EU27 energy system is modelled to investigate the impact of district heating. The results indicate that a combination of heat savings, district heating in urban areas, and individual heat pumps in rural areas will enable the EU27 to reach its greenhouse gas emission targets by 2050......, but at a cheaper price than a scenario which focuses primarily on the implementation of heat savings....

  5. Risk benefit analysis of site alternatives for a nuclear power plant producing both electricity and district heat

    International Nuclear Information System (INIS)

    Savolainen, I.; Vuori, S.

    1978-01-01

    The environmental impacts due to radioactive releases in normal operation and accidents are primarily assessed for each site as also the district heat transmission costs. Secondarily the risk components are converted to a compatible form, expressed in monetary units, and compared directly to district heat transmission costs. Annual savings from the shortening of the district heat transmission line are clearly larger than the monetary value given to the expectation of the increased risk. (author)

  6. Heat demand profiles of energy conservation measures in buildings and their impact on a district heating system

    International Nuclear Information System (INIS)

    Lundström, Lukas; Wallin, Fredrik

    2016-01-01

    Highlights: • Energy savings impact on an low CO 2 emitting district heating system. • Heat profiles of eight building energy conservation measures. • Exhaust air heat pump, heat recovery ventilation, electricity savings etc. • Heat load weather normalisation with segmented multivariable linear regression. - Abstract: This study highlights the forthcoming problem with diminishing environmental benefits from heat demand reducing energy conservation measures (ECM) of buildings within district heating systems (DHS), as the supply side is becoming “greener” and more primary energy efficient. In this study heat demand profiles and annual electricity-to-heat factors of ECMs in buildings are computed and their impact on system efficiency and greenhouse gas emissions of a Swedish biomass fuelled and combined heat and power utilising DHS are assessed. A weather normalising method for the DHS heat load is developed, combining segmented multivariable linear regressions with typical meteorological year weather data to enable the DHS model and the buildings model to work under the same weather conditions. Improving the buildings’ envelope insulation level and thereby levelling out the DHS heat load curve reduces greenhouse gas emissions and improves primary energy efficiency. Reducing household electricity use proves to be highly beneficial, partly because it increases heat demand, allowing for more cogeneration of electricity. However the other ECMs considered may cause increased greenhouse gas emissions, mainly because of their adverse impact on the cogeneration of electricity. If biomass fuels are considered as residuals, and thus assigned low primary energy factors, primary energy efficiency decreases when implementing ECMs that lower heat demand.

  7. Basic methods for automated fault detection and energy data validation in existing district heating systems

    OpenAIRE

    Sandin, Fredrik; Gustafsson, Jonas; Delsing, Jerker; Eklund, Robert

    2012-01-01

    Fault detection and diagnostics (FDD) of district heating substations (DHS) are important activities because malfunctioning components can lead to incorrect billing and waste of energy. Although FDD has been an activate research area for nearly two decades, only a few simple tools are commonly deployed in the district energy industry. Some of the methods proposed in the literature are promising, but their complexity may prevent broader application. Other methods require sensor data that are n...

  8. Multifunctional absorption technology in district heating systems; Absorptionsteknik med multifunktion i fjaerrvaermesystem

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Viktoria; Setterwall, Fredrik

    2010-05-15

    Within the framework of the IEA's implementing agreement on heat pumping technologies, a state-of-the-art assessment of absorption technology was presented the year 2000. There, barriers for increased implementation of absorption technology were pointed out as being the high investment cost, as well as lack of knowledge with engineers and other actors. The project presented herein has analyzed the situation ten years later, with a wide scope of using the absorption technology - from ice to steam production in a district energy system. The overall aim of the presented project is to provide new knowledge on the technical and economical possibilities of integrating multiple function absorption technology in district energy systems. Also, new knowledge on important design parameters for practical and cost-effective design is given, for example the influence of temperatures (heat source as well as heat sink) and desired COP. A combination of renewed state-of-the-art assessment and new calculations has been used to reach this goal. The state-of-the-art assessment show that the increased focus on combined heat and power (CHP) for resource-efficient energy conversion go hand in hand with an increased interest in thermally driven cooling (TDC) technology. This project has identified the following to be specifically district energy adapted in absorption cooling: - design for low return temperature of the heat carrier leaving the generator part - design for 'high enough' COP maintained at part load for heat source temperatures as low as 70 deg C. - cost minimization by optimal sizing of heat exchanger surfaces for district energy design criteria (as opposed to accepting 'off-the-shelf' designs intended for higher operating temperatures). The overall analysis and findings regarding trigeneration concludes that: a. a holistic view of the production of power, heat and cold should be adopted when considering absorption technology in district energy

  9. Decentralized substations for low-temperature district heating with no Legionella risk, and low return temperatures

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Li, Hongwei; Svendsen, Svend

    2016-01-01

    with domestic hot water (DHW) circulation. In this study, a system with decentralized substations was analysed as a solution to this problem. Furthermore, a modification for the decentralized substation system were proposed in order to reduce the average return temperature. Models of conventional system...... with medium-temperature district heating, decentralized substation system with LTDH, and innovative decentralized substation system with LTDH were built based on the information of a case building. The annual distribution heat loss and the operating costs of the three scenarios were calculated and compared....... From the results, realizing LTDH by the decentralized substation unit, 30% of the annual distribution heat loss inside the building can be saved compared to a conventional system with medium-temperature district heating. Replacing the bypass pipe with an in-line supply pipe and a heat pump...

  10. Application of thermohydraulic dispatcher in low temperature district heating systems for decreasing heat carrier transportation energy cost and increasing reliability of heat supply

    Science.gov (United States)

    Yavorovsky, Y. V.; Romanov, D. O.; Sennikov, V. V.; Sultanguzin, I. A.; Malenkov, A. S.; Zhigulina, E. V.; Lulaev, A. V.

    2017-11-01

    Low pressure district heating systems have low breakdown rate and allow decreasing heat carrier transportation energy cost by means of avoiding throttling of available water head. One of the basic elements of such systems is thermohydraulic dispatcher (THD) which separates primary circuit and secondary circuit (or circuits) that allows avoiding mutual hydraulic influence of circuits on each other and reducing water heads of network pumps. Analysis of perspective ways of using thermohydraulic dispatcher (THD) in low temperature district heating systems is made in this paper. Principal scheme and mathematical model of low pressure and temperature district heating system based on CHP generation with THD are considered. The main advantages of such systems are pointed out.

  11. Master plan for development of the district heating system in Teplice. Final version

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    The City of Teplice is located in North Bohemia in the Czech Republic. Teplic has a population of approximately 65,000. Today, the heat supply in the Teplice area is covered by district heating based on steam, natural gas fired boilers (block heating stations) and individual heating with small gas fired boilers. The existing district heating system has some major problems: not all district heating networks are connected to the main system although capacity is available; natural gas is an imported and expensive fuel and too valuable to be used for heating; a high percentages of the heat is lost in the distribution network; many leakages in the distribution network make re-investment necessary; The hop tap water system is in a very bad condition and must be changed; the technology of the present system is old-fashioned, and has an inflexible operating regime. All these problems will have to be dealt with within the next 5 to 10 years, and a plan solving the problems has to be made. As an alternative to the development of an integrated hot water district heating system, a plan for the development of a number of heat islands has been analysed. This development strategy is agreed upon and recommended by both the Consultant and NB-DHC. A system with a total capacity of 150 MW must be established and the different areas of Teplice connected to a new hot water network in the period between year 2000 and 2010. A plan for connection of the different areas in Teplice is made, and the total investments in the system are estimated. (EG)

  12. Metamorphoses of cogeneration-based district heating in Romania: A case study

    International Nuclear Information System (INIS)

    Iacobescu, Flavius; Badescu, Viorel

    2011-01-01

    The paper presents the birth and evolution of the cogeneration-based district heating (DH) system in a medium size city in Romania (Targoviste). The evolution of the industrialization degree was the main factor which controlled the population growth and led to a continuous reconfiguration of the DH system. The DH system assisted by cogeneration emerged as a solution in a certain phase of the demographic development of the city. The political and social changes occurring in Romania after 1990 have had important negative consequences on the DH systems in small towns. In Targoviste the DH system survived but in 2001 the solution based on cogeneration became economically inefficient, due to the low technical quality of the existing equipment and the low gas prices, to the procedure of setting the DH tariffs and the service cost at consumer's level and to some bureaucratic problems. Energy policy measures taken at national and local levels in 2003 and 2005 led to the re-establishment of the cogeneration-based district heating in 2005. However, a different technical solution has been adopted. Details about the present (2009) cogeneration-based DH system in Targoviste are presented together with several technical and economical indicators. The main conclusion is that by a proper amendment of the technical solutions, cogeneration could be a viable solution for DH even in case of abrupt social and demographic changes, such as those occurring in Romania after 1990. - Research Highlights: →Birth and evolution of the cogeneration-based district heating system in a medium size city. →The industrialization degree is the main factor which controlled the reconfiguration of the district heating system. →Each stage of the evolution of district heating system has been a technological leap. →Cogeneration is a solution for district heating even in case of abrupt social changes.

  13. Feasibility study on rehabilitation and improvement of thermal power plants, district heating and heat supply system in Botosani City

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Discussions have been given on the improvement and modification project intended of saving energies and reducing greenhouse gas emission in the Botosani district heating and heat supplying facilities in Romania. Thirty years have elapsed since the building of the Botosani district heating and heat supplying facilities, whereas noticeable energy loss has occurred due to aged deterioration, such as thermal efficiency decrease, performance decrease, and hot water leakage due to piping corrosion. The present project is intended to improve the heat production and power generation facility efficiencies, and reduce the heat loss in heat transportation and distribution to less than 5%. The improvements will be implemented by replacing and rehabilitating the existing boilers, replacing the turbine generators, and replacing the transportation and distribution pipelines and heat exchangers. As a result of the discussions, the present project is estimated to result in annual fuel conservation of 35,820 tons of crude oil equivalent, and annual reduction of the greenhouse gas emission of 110,835 t-CO2. The total amount of the initial investment for the project would be 11.369 billion yen, and the payback period would be 12 years. The project will produce profit of 31.358 billion yen in 20 years, thus the project is financially feasible. (NEDO)

  14. Integration of heat treatment of wood with cogeneration production and district heating; Vaermebehandling av trae integrerad med kraftvaermeproduktion och fjaerrvaerme

    Energy Technology Data Exchange (ETDEWEB)

    Delin, Lennart; Essen, Henrik (AaF, Stockholm (Sweden))

    2011-05-15

    Heat treatment of wood changes the properties of wood so that the moisture uptake is reduced and the wood movements are reduced at variations in the ambient air humidity. The wood gets an increased resistance to rot and can therefore replace impregnated wood in certain applications. Heat treated wood is however not suitable for direct contact with soil. The strength is also reduced by heat treatment, so it is not recommended for supporting constructions. No additives whatsoever are used in the treatment, so the heat treated wood is very advantageous from an environmental point of view. The wood is dried completely at the heat treatment and heated to about 200 deg C. The question has hence been put, if it is advantageous to collocate a heat treatment plant with district heating or a power cogeneration plant. The aim of the study is to assess the value of such a collocation. Existing heat treatment plants are both few and small and the calculations have hence been made for how a large plant could be designed. A market study is included to assess the market for this type of plants. This shows that the present market for heat treated wood is very small. A full scale treatment plant of the type discussed in this study could probably not be built, since even single plants of this size would require a too large part of the market. The potential to replace impregnated wood is on the other hand very large. The cost for large scale heat treatment should be significantly lower than for impregnated wood and the cost for handling hazardous waste (which impregnated wood is classified as) is also removed. There should therefore be a potential for a future much larger volume of heat treated wood. The study shows that the energetic profit of collocation of a heat treatment plant for wood with district heating or power cogeneration plants is of lower importance. Maximally about 0.5 MSEK/year can be saved for a 25 000 m3/year plant. The initial drying of all sawn lumber has much more

  15. Decarbonising the Hungarian Electricity and Heat Sectors: What Is the Least impossible?

    International Nuclear Information System (INIS)

    Kaderjak, P.

    2012-01-01

    The presentation will report on an economic assessment of decarbonisation scenarios for the Hungarian electricity and heat sectors by 2050. The assessment is based on economic modeling that assumes an expanding application of existing technologies. The results suggest that CO 2 abatement in the heat sector might be a cheaper and more realistic option for decarbonisation in the Hungarian case. With regard to the electricity sector, decarbonisation foreseen in the Commission's 2050 vision (90-95%) is not feasible without a massive application of CCS technology or without a non-foreseeable technology breakthrough.(author)

  16. A multi-biofuel, fluidised-bed district heating plant in Sweden

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    At the end of 1984, the city of Haessleholm in Sweden started up a 65 MW district heating plant which included a 14 MW solid fuel plant. The plant included a specially-designed fluidised-bed boiler, capable of burning all grades of solid fuel, including organic fuel of such low grade that no other boilers around Haessleholm could use it. By 1992, the district heating system served some 250 detached houses and 6,000 flats as well as several schools and industrial premises. The biofuel boiler provides almost 60% of the energy required. (UK)

  17. Application of an intermediate LWR for electricity production and hot-water district heating

    Energy Technology Data Exchange (ETDEWEB)

    1983-05-01

    The objective of the study is to evaluate the technical and economic feasibility of a 400 MWe Consolidated Nuclear Steam System (CNSS) for supplying district heat to the Minneapolis/St. Paul area. A total of three CNSS reactor sites, located various distances from the Minneapolis-St. Paul area load center, are evaluated. The distance from the load center is determined by the credited safety features of the plant design. Each site is also evaluated for three different hot water supply/return temperatures providing a total of nine CNSS study cases. The cost of district heat delivered to the load center is determined for each case.

  18. Optimisation of a Swedish district heating system with reduced heat demand due to energy efficiency measures in residential buildings

    International Nuclear Information System (INIS)

    Åberg, M.; Henning, D.

    2011-01-01

    The development towards more energy efficient buildings, as well as the expansion of district heating (DH) networks, is generally considered to reduce environmental impact. But the combined effect of these two progressions is more controversial. A reduced heat demand (HD) due to higher energy efficiency in buildings might hamper co-production of electricity and DH. In Sweden, co-produced electricity is normally considered to displace electricity from less efficient European condensing power plants. In this study, a potential HD reduction due to energy efficiency measures in the existing building stock in the Swedish city Linköping is calculated. The impact of HD reduction on heat and electricity production in the Linköping DH system is investigated by using the energy system optimisation model MODEST. Energy efficiency measures in buildings reduce seasonal HD variations. Model results show that HD reductions primarily decrease heat-only production. The electricity-to-heat output ratio for the system is increased for HD reductions up to 30%. Local and global CO 2 emissions are reduced. If co-produced electricity replaces electricity from coal-fired condensing power plants, a 20% HD reduction is optimal for decreasing global CO 2 emissions in the analysed DH system. - Highlights: ► A MODEST optimisation model of the Linköping district heating system is used. ► The impact of heat demand reduction on heat and electricity production is examined. ► Model results show that heat demand reductions decrease heat-only production. ► Local and global CO 2 emissions are reduced. ► The system electricity-to-heat output increases for reduced heat demand up to 30%.

  19. Decreasing of energy consumption for space heating in existing residential buildings; Combined geothermal and gas district heating systems

    International Nuclear Information System (INIS)

    Rosca, Marcel

    2000-01-01

    The City of Oradea, Romania, has a population of about 230 000 inhabitants. Almost 70% of the total heat demand, including industrial, is supplied by a classical East European type district heating system. The heat is supplied by two low grade coal fired co-generation power plants. The oldest distribution networks and substitutions, as well as one power plant, are 35 years old and require renovation or even reconstruction. The geothermal reservoir located under the city supplies at present 2,2% of the total heat demand. By generalizing the reinjection, the production can be increased to supply about 8% of the total heat demand, without any significant reservoir pressure or temperature decline over 25 years. Another potential energy source is natural gas, a main transport pipeline running close to the city. Two possible scenarios are envisaged to replace the low grade coal by natural gas and geothermal energy as heat sources for Oradea. In one scenario, the geothermal energy supplies the heat for tap water heating and the base load for space heating in a limited number of substations, with peak load being produced by natural gas fired boilers. In the other scenario, the geothermal energy is only used for tap water heating. In both scenarios, all substations are converted into heat plants, natural gas being the main energy source. The technical, economic, and environmental assessment of the two proposed scenarios are compared with each other, as well as with the existing district heating system. Two other possible options, namely to renovate and convert the existing co-generation power plants to natural gas fired boilers or to gas turbines, are only briefly discussed, being considered unrealistic, at least for the short and medium term future. (Author)

  20. Modeling Transient Heat Transfer in Small-Size Twin Pipes for End-User Connections to Low-Energy District Heating Networks

    DEFF Research Database (Denmark)

    Dalla Rosa, Alessandro; Li, Hongwei; Svendsen, Svend

    2013-01-01

    The low-energy district heating concept has the potential of increasing the energy and exergy efficiencies of heat supply systems and of exploiting renewable energy, provided technical solutions for its wide application can be developed and implemented. This paper investigates the dynamic behaviour...... of district heating branch pipes in low-temperature operation (supply temperature 50-55°C and return temperature 20-25°C). We looked at state-of-the-art district heating branch pipes, suitable for the connection of a typical single-family house to a substation equipped with a heat exchanger for domestic hot...

  1. Modeling hourly consumption of electricity and district heat in non-residential buildings

    International Nuclear Information System (INIS)

    Kipping, A.; Trømborg, E.

    2017-01-01

    Models for hourly consumption of heat and electricity in different consumer groups on a regional level can yield important data for energy system planning and management. In this study hourly meter data, combined with cross-sectional data derived from the Norwegian energy label database, is used to model hourly consumption of both district heat and electrical energy in office buildings and schools which either use direct electric heating (DEH) or non-electric hydronic heating (OHH). The results of the study show that modeled hourly total energy consumption in buildings with DEH and in buildings with OHH (supplied by district heat) exhibits differences, e.g. due to differences in heat distribution and control systems. In a normal year, in office buildings with OHH the main part of total modeled energy consumption is used for electric appliances, while in schools with OHH the main part is used for heating. In buildings with OHH the share of modeled annual heating energy is higher than in buildings with DEH. Although based on small samples our regression results indicate that the presented method can be used for modeling hourly energy consumption in non-residential buildings, but also that larger samples and additional cross-sectional information could yield improved models and more reliable results. - Highlights: • Schools with district heating (DH) tend to use less night-setback. • DH in office buildings tends to start earlier than direct electric heating (DEH). • In schools with DH the main part of annual energy consumption is used for heating. • In office buildings with DH the main part is used for electric appliances. • Buildings with DH use a larger share of energy for heating than buildings with DEH.

  2. Production of dry wood chips in connection with a district heating plant

    Directory of Open Access Journals (Sweden)

    Yrjölä Jukka

    2004-01-01

    Full Text Available Moisture and its variation in wood chips make the control of burning in small scale heating appliances difficult resulting in emissions and loss of efficiency. If the quality of wood chips would be better, i. e. dried and sieved fuel with more uniform size distribution would be avail able, the burning could be much cleaner and efficiency higher. In addition higher power out put could be obtained and the investment costs of the burning appliances would be lower. The production of sieved and dried wood chip with good quality could be accomplished in connection with a district heating plant. Then the plant would make profit, in addition to the district heat, from the dried wood chips sold to the neighboring buildings and enterprises sep a rated from the district heating net using wood chips in energy production. The peak power of a district heating plant is required only a short time during the coldest days of the winter. Then the excess capacity during the milder days can be used as heat source for drying of wood chips to be marketed. Then wood chips are sieved and the fuel with best quality is sold and the reject is used as fuel in the plant it self. In a larger district heating plant, quality of the fuel does not need to be so high In this paper the effect of moisture on the fuel chain and on the boiler is discussed. Energy and mass balance calculations as a tool of system design is described and the characteristics of proposed dry chips production method is discussed.

  3. Istra district heating system. General technical report. Appendix 1 to the master plan

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-09-01

    The objective of the master plan project is to improve the heat supply in Istra. The considerable system losses from the fuel supplied to the end-users are one issue for improvement. At the same time, the current system operation results in poor quality heat for the consumers. Due to the inflexibility of the system the dwellings/premises of the consumers are either overheated or insufficiently heated. The financial situation in Istra, the legal ownership of the district heating system and consumers' lacking ability to pay limit the possibilities for system improvements. The Master Plan and Feasibility Study evaluates four different development scenarios. Each of the scenarios is compared to the current situation in Istra, where nothing is done to change the system, but only to operate the present system in a sustainable way. The sustainable operation of the district heating system includes all necessary renovations and component replacements necessary. The project does not take into account the present financial situation in Istra, which has resulted in less maintenance than necessary. This situation is not a comparable parameter, as it is not sustainable and will lead to a breakdown of the heat supply within a short time horizon. The General Technical Report evaluates the technical situation and describes system improvements at a general level. The intention with this report is to provide important information useful to other district heating companies in Russia. (au)

  4. Korean district heating. Part 1: A general report on Korean district heating 1994/1995; Fjaerrvaerme i Korea. Del 1: En allmaen redovisning av koreansk fjaerrvaerme aarsskiftet 1994/95

    Energy Technology Data Exchange (ETDEWEB)

    Joensson, Mats; Olsson, Nils

    1996-02-01

    This thesis describes the conditions for district heating in the Republic of Korea at the turn of the year 1994-95. It is based on a study made in Seoul at Korea District Heating Corporation, which is the largest district heating utility in Korea. The substations were particularly studied. District heating was introduced in Korea in the 80s because of the environmental advantages. KHDC was established in 1985 and in 1994 they provided 340 000 households with district heating. By the year of 2001 KDHC plans to supply 45% of the heating in Seoul with its 12 million inhabitants. KDHC receives most of its thermal energy from combined heat and power plants that use natural gas as fuel. In 1991 KDHC initiated a collaboration with Ekono of Finland to develop more advanced technology in Korea. Therefore the Finnish standard, which is similar to Swedish standard, has left it`s mark on the Korean district heating technology. Typical for the Korean substation is that the heat exchangers are connected in parallel in only one step. KDHC:s expansion will, within a couple of years, help to make Korea one of the leading countries in modern district heating. 9 refs, 3 figs, 2 tabs

  5. Determination of Optimum Network Layout for Low-Energy District Heating Systems with Different Substation Types

    DEFF Research Database (Denmark)

    Tol, Hakan; Svendsen, Svend

    2011-01-01

    In this paper three different District Heating (DH) network types, which comprise substations with storage tank, and with instantaneous heat exchanger (each for domestic hot water production); and booster pumps installed in the beginning of each street at the latter network type, are pointed out...... temperature drop at supply in low heat demand conditions during summer months, are presented with the results of dynamic simulations, carried out in the Termis software with the input data of randomly generated heat demand of consumers in the basis of simultaneity factor effect in each pipe segment at the DH...

  6. Situation analysis in relation to district heating and CHP in the Baltic Sea Region: Estonia, Latvia, Lithuania, Poland, Russia, Kaliningrad

    International Nuclear Information System (INIS)

    2000-11-01

    The situation analysis embraces chapters on: Estonia, Kaliningrad, Latvia, Lithuania, Poland and Russia, which experience varying degrees of difficulties with the transition to a market economy, and with integrating into the world market. In the following, the focus is on Lithuania, which has been visited during the project period. Lithuania has specific problems due to the existence of the Ignalina power plant, but has nevertheless characteristics, which apply to Estonia and Latvia as well. The problem with the quality of heat supply is rampant in all the countries, as is legal framework for the sector, except in Poland, which has generally attracted much attention from investors over the last ten years and has experienced a relatively sound political development in the energy sector. The main problem in all countries seem to relate to the policy development. The case of Lithuania confirms this. Following the observations on Lithuania, it is attempted to establish some points of concern, which are relevant to a greater or lesser extent in all countries, as well as some suggestions on how to move towards a solution of those problems. As mentioned Poland is generally in a better position, technically and politically than the three Baltic states, whereas Russia still needs to progress much on those issues. The general recommendations for initiatives in the Baltic countries in question are in brief: Establishing a clear view at governmental level of what the EU and liberalisation will bring, and what needs to be done additionally to secure main energy political objectives. Issues such as security of supply, environmental protection, low cost energy supplies and security of investments need to be thoroughly discussed at national level. It is important to understand that EU Directives provide a framework, not an answer to the future of the energy sector. Reinforcement of governmental bodies that deal with the practical problems of the energy sector. The main task of

  7. Slowpoke: a role for nuclear technology in district heating

    International Nuclear Information System (INIS)

    Lynch, G.F.

    1987-08-01

    The successful application of the SLOWPOKE concept to satisfy the heating needs of institutions and building complexes is described. Although the load factor for heating in Japan may not be as high as those experienced in other countries of the northern hemipshere, this particular application clearly demonstrates that small, special purpose, ultra-safe nuclear energy sources are technically and economically viable. They can be designed for easy operation and maintenance, to be located in urban areas and remote communities, thereby satsifying a broad spectrum of energy needs that cannot be served by central nuclear electrical generators

  8. District heat in the environmental model city Vienna; Fernwaerme in der Umweltmusterstadt Wien

    Energy Technology Data Exchange (ETDEWEB)

    Wischinka, A. [Fernwaerme Wien Gesellschaft mbH, Wien (Austria)

    1998-10-01

    Thanks to the extension of its district heating system and the integration of low-emission waste incineration plants, Vienna possesses one of the most environment friendly energy systems. This makes Vienna an environmental model city. Goals for the year 2000 are: - 2,000 MW operated heat peak load, - 200,000 district-heated dwellings, - 4,000 special sales contracts, - 1,000 km network length (500 km primary network, 500 km secondary network), - heat sales of 5,000 GWh, - ATS 5 billion sales. (orig.) [Deutsch] Durch den Ausbau des Fernwaermesystems unter Einbeziehung der emissionsarmen Muellverbrennungsanlagen hat Wien eines der umweltfreundlichsten Energiesysteme. Das macht Wien zu einer Umweltmusterstadt. Die Ziele fuer das Jahr 2000 lauten: - 2 000 MW gefahrene Waermehoechstlast, - 200 000 fernwaermeversorgte Wohnungen, - 4000 Sonderabnehmer, 1 000 km Netzlaenge (500 km Primaernetz, 500 km Sekundaernetz), - 5000 GWh Waermeverkauf, - 5 Milliarden ATS Umsatz. (orig.)

  9. District heating and cooling systems for communities through power plant retrofit distribution network. Phase 2. Final report, 1 March 1980-31 January 1984

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    The potential for district heating was examined in terms of a total (regional) system and two subsystems of overlapping scales. The basis of the economic analysis of district heating was that the utility's electric and gas customers would not be economically burdened by the implementation of district heating, and that any incremental costs due to district heating (e.g. district heating capital and operating costs, replacement electric power, abandonment of unamortized gas mains) would be charged to district heating customers.

  10. Geothermal district heating system in Tanggu, Tianjin, China

    International Nuclear Information System (INIS)

    Jinrong, C.

    1992-01-01

    Tanggu is a harbor and industrial area and is the location of Tianjin Harbor, Tianjin Bonded Area and Tianjin Economic Development Area. It covers an area of 859 km 2 and has a population of 430,000. Tanggu Geothermal Field is located at the western coast of Bohai Sea. This area belongs to the depression area of North China geologically. Neogene strata of Guantao Group is distributed widely in this region. Good permeability, large thickness, and high conductivity make it form a regional low-temperature porous reservoir. The reservoir is buried to a depth of 1,600 - 2,100 m. The total thickness of about 500 m can be divided into upper and lower sections including three aquifers. Geothermal space heating tests of Tanggu started in 1980. Up to the present, there are a total of 16 geothermal wells in Tanggu. Thirteen of them were drilled in the shallower aquifer. The total production rate of thermal water is 3.636 x 10 6 m 3 annually. The net production rate used for space heating is 3.10 x 10 6 m 3 from 11 wells. It has heated an area of 620 x 10 3 m 2 and has solved winter heating for 100 thousand people

  11. District Heating at Power Failures - Final Report; Fjaerrvaerme vid Elavbrott - Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Lauenburg, Patrick; Johansson, Per-Olof

    2008-11-15

    Our society is vulnerable to prolonged power cuts. In cold weather interrupted heating is one of the most serious threats. District heating is available at most locations in Sweden and if heat can be transferred to the connected buildings at a power failure, it is of great importance for securing energy supply. In this work it was found that there are good opportunities for upholding heat supply at a power failure through self-circulation in connected radiator system, which has previously been overlooked. Self Circulation occurs when there is a sufficiently large temperature difference between forward and return line in the radiator system. The control and circulation in radiator systems will fail, but if the district heating water can continue to pass through the heat exchangers of the radiator systems self-circulation can occur. A prerequisite for self-circulation in the individual buildings to work is therefore to district heating network can operate at a power failure. District heating supply must have back to maintain the production and distribution of district heating, which is not always the case. Our studies show that there is every reason to this. Moreover there are customers that have their own reserve aggregates, such as hospitals, which are dependent on the district heating network function. In an extensive power failure, it may be desirable to establish a smaller grid, separate from backbone, using local electricity generation. The establishment of such a network requires there is local production which can start to loose voltage networks and has necessary control equipment for the frequency approach. In Malmoe, it is now possible to establish a such a network with the help of local production units. A prerequisite is that there are consumption of heating. It is not unusual for power plants (which produce both electricity and heat) is dependent on the pipe system for cooling the production of electricity. One can from the results also argue that every

  12. Urban form and heat consumption, a comparative study in Copenhagen districts

    DEFF Research Database (Denmark)

    Mohammadi Dehcheshme, Mostafa; Jensen, Jesper Ole

    the implications of urban development and form in terms of its impact on energy consumption in ten districts of Copenhagen city. As comparative study, this paper is trying to respond the question: How does urban form impact the heat consumption in households in Copenhagen districts? To respond this question, two...... models, housing level model and city level model, are presented and each model includes the part of urban form indicators. Finally in the comparative frame, the impacts of urban form indicators on heat consumption are analyzed for the Copenhagen districts.......Since urban form and land use patterns significantly influence the cities energy needs, the study linkage of energy consumption and urban form is an interdisciplinary issue and one the current central topics of urban planners in recent years. Our concern in this paper, therefore, is to address...

  13. Production and Distribution Planning in District Heating Systems; Produktions- och distributionsplanering av fjaerrvaerme

    Energy Technology Data Exchange (ETDEWEB)

    Kvarnstroem, Johan; Dotzauer, Erik; Dahlquist, Erik

    2006-12-15

    To produce heat and power is costly. Therefore it is important for the district heating companies to plan and optimize the production. The aim with the present project is to find out how also the distribution of heat can be considered in the planning. The principal procedure is to first construct a prediction of the heat demand, and then, given the demand prediction, construct the production plan. Due to the complexity of the problem, the need for mathematical models is obvious. The report gives a survey introduction to production planning in district heating systems and presents a model for the purpose. The model is developed for one of the district heating systems in Stockholm owned by the energy company Fortum. Traditionally, models for production planning do not consider the distribution network. In such models, usually the methodology Mixed Integer Programming (MIP) is used. The report suggests how the distribution network can be modeled as a MIP; it shall be possible to link the network model to existing software that models the production plants as MIP. The model is developed in the programming language GAMS. Analysis and results are presented. The results show that the suggested plans vary depending on if the distribution network is considered or not. The report also suggests how a simple sensitivity analysis of the production plans can be performed. This is necessary since there are always uncertainties associated with weather- and load predictions.

  14. A modular approach to inverse modelling of a district heating facility with seasonal thermal energy storage

    DEFF Research Database (Denmark)

    Tordrup, Karl Woldum; Poulsen, Uffe Vestergaard; Nielsen, Carsten

    2017-01-01

    We use a modular approach to develop a TRNSYS model for a district heating facility by applying inverse modelling to one year of operational data for individual components. We assemble the components into a single TRNSYS model for the full system using the accumulation tanks as a central hub...

  15. Analysis and research on promising solutions of low temperature district heating without risk of legionella

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Li, Hongwei; Fog, Jette M.

    2014-01-01

    resources. The most crucial restriction for applying low temperature district heating is the worry about the breakout of legionella, which exists preferably in low temperature hot water systems. Several novel techniques such as electric tracing and flat station were investigated for such dilemma. The pros...

  16. A modular approach to inverse modelling of a district heating facility with seasonal thermal energy storage

    DEFF Research Database (Denmark)

    Tordrup, Karl Woldum; Poulsen, Uffe Vestergaard; Nielsen, Carsten

    2017-01-01

    We use a modular approach to develop a TRNSYS model for a district heating facility by applying inverse modelling to one year of operational data for individual components. We assemble the components into a single TRNSYS model for the full system using the accumulation tanks as a central hub conn...

  17. Magneto-Inductive Communication among Pumps in a District Heating System

    DEFF Research Database (Denmark)

    Afkhami Meybodi, Soroush; Pardo, Pablo; Dohler, Mischa

    2011-01-01

    Realizing distributed control for a large scale district heating plant needs a metropolitan wireless communication framework among its pumps. The main challenge at PHY layer here is coverage rather than interference. This paper reviews the potential methods and proposes the use of magnetic induct...

  18. Environmental Assessment and FONSI for the Bison School District Heating Plant Project (Institutional Conservation Program [ICP]).

    Science.gov (United States)

    Department of Energy, Washington, DC.

    This paper examines the environmental impacts of replacing the Bison, South Dakota School District's elementary and high school heating system consisting of oil-fired boilers, and supporting electrical components with a new coal-fired boiler and supporting control system piping. Various alternative systems are also examined, including purchasing a…

  19. The design of integrated cooling processes in district heating systems; Kylprocessers design i fjaerrvaermesystem

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Viktoria [Royal Inst. of Technology, Stockholm (SE). Dept. of Chemical Engineering and Technology; Setterwall, Fredrik [Fredrik Setterwall Konsult AB, Sollentuna (Sweden); Andersson, Mikael [AB Berglunds Rostfria, Boden (Sweden)

    2005-07-01

    This report presents the results from an investigation regarding the design of integrated cooling processes in district heating systems. Increasing investment levels in district heating networks combined with expanding comfort cooling demand makes heat-driven cooling processes extremely interesting. This solution has a great potential tbe cost effective. At the same time, the problem with the environmentally harmful refrigerants used in conventional vapor compression chillers is avoided. In many cases it is beneficial for the district heating provider to lower the supply and/or return temperatures in the network, at least for part of the year. In combined heat and power generation (CHP) a lower supply temperature means that the electricity yield increases. In this context, it is important to consider that conventional absorption chillers are designed to run on 120 deg C heat. However,they can work on heat with temperature as low as 80 deg C if a chiller with a large enough generator area is used, although this has a negative impact on the dimensions of other components and leads ta lower coefficient of performance. For these reasons low temperature driven absorption chillers have been developed in recent years. Two concepts (from different manufacturers) are now available on the market. Factors that affect the choice of district heat-integrated cooling processes have been investigated in this study. Key system aspects that embody a holistic view on the production of heating, cooling and power are especially highlighted. Important tasks have been: To quantify the following effects on the design of an integrated cooling process: the temperatures in the district heating net, available cooling water temperature (to cool the absorber and condenser), electricity price, and the composition of the energy system (e.g. fuel and CHP or power-only mode of operation). To analyze the potential of the low temperature driven chiller concept with regards to energy and cost

  20. A cost-effective evaluation of biomass district heating in rural communities

    International Nuclear Information System (INIS)

    Hendricks, Aaron M.; Wagner, John E.; Volk, Timothy A.; Newman, David H.; Brown, Tristan R.

    2016-01-01

    Highlights: • Develop a cost-effective model using secondary data examining delivering heat through Biomass District Heating (BDH). • Eight of ten rural villages studied could cost-effectively deliver heat through BDH below the 2013 price of heating oil. • 80% of the annual cost of BDH was attributable to capital expenses. • Erratic fuel oil prices substantially impact future feasibility. • Village level feasibility is highly-influenced by the presence of large heat demanders. - Abstract: The economic feasibility of Biomass District Heating (BDH) networks in rural villages is largely unknown. A cost-effective evaluation tool is developed to examine the feasibility of BDH in rural communities using secondary data sources. The approach is unique in that it accounts for all the major capital expenses: energy center, distribution network, and energy transfer stations, as well as biomass procurement. BDH would deliver heat below #2 fuel oil in eight of the ten rural study villages examined, saving nearly $500,000 per year in heating expenses while demanding less than 5% of the forest residues sustainably available regionally. Capital costs comprised over 80% of total costs, illuminating the importance of reaching a sufficient heat density. Reducing capital costs by 1% lowers total cost by $93,000 per year. Extending capital payment period length five years or lowering interest rates has the next highest influence decreasing delivered heat price 0.49% and 0.35% for each 1% change, respectively. This highlights that specific building heat is a strong determinant of feasibility given the relative influence of high-demanding users on the overall village heat-density. Finally, we use a stochastic analysis projecting future #2 fuel oil prices, incorporating historical variability, to determine the probability of future BDH feasibility. Although future oil prices drop below the BDH feasibility threshold, the villages retain a 22–53% probability of feasibility after

  1. Clustering-based analysis for residential district heating data

    DEFF Research Database (Denmark)

    Gianniou, Panagiota; Liu, Xiufeng; Heller, Alfred

    2018-01-01

    residential heating consumption data and evaluate information included in national building databases. The proposed method uses the K-means algorithm to segment consumption groups based on consumption intensity and representative patterns and ranks the groups according to daily consumption. This paper also......The wide use of smart meters enables collection of a large amount of fine-granular time series, which can be used to improve the understanding of consumption behavior and used for consumption optimization. This paper presents a clustering-based knowledge discovery in databases method to analyze...

  2. Identifying the optimal supply temperature in district heating networks - A modelling approach

    DEFF Research Database (Denmark)

    Mohammadi, Soma; Bojesen, Carsten

    2014-01-01

    dynamically while the flow and pressure are calculated on the basis of steady state conditions. The implicit finite element method is applied to simulate the transient temperature behaviour in the network. Pipe network heat losses, pressure drop in the network and return temperature to the plant...... of this study is to develop a model for thermo-hydraulic calculation of low temperature DH system. The modelling is performed with emphasis on transient heat transfer in pipe networks. The pseudo-dynamic approach is adopted to model the District Heating Network [DHN] behaviour which estimates the temperature...

  3. Life Cycle Assessment of Miscanthus as a Fuel Alternative in District Heat Production

    DEFF Research Database (Denmark)

    Parajuli, Ranjan; Dalgaard, Tommy; Nguyen, Thu Lan Thi

    2013-01-01

    better than in the boilerfrom the stand point of GWP and savings in fossil fuels, but leads to a higher LU.A comparison between Miscanthus and NG shows that the former in spite of possessing advantage in reducing GWP and NRE use,additional land required for it could be seen as a disadvantage. Key words......This study assesses the environmental performance of district heat production based on Miscanthus as a fuel input and compares it with Natural Gas (NG). As a baseline scenario, we assume that the process of energy conversion from Miscanthus to heat takes place in a Combined Heat and Power (CHP...

  4. Improving thermal performance of an existing UK district heat network: a case for temperature optimization

    DEFF Research Database (Denmark)

    Tunzi, Michele; Boukhanouf, Rabah; Li, Hongwei

    2018-01-01

    the existing heat network operating parameters, and defining the optimum supply and return temperature. A stepwise temperature optimization technique of plate radiators heat emitters was applied to control the buildings indoor thermal comfort using night set back temperature strategy of 21/18 °C...... networks at optimum performance and achieving lower return temperature. It was also pointed out that optimal operation of future low temperature district heat networks will require close engagement between the operator and the end user through incentives of mutual benefit....

  5. Initiative for local district heating. New chances for municipal utilities. Boundary conditions for the heat market; Initiative Nahwaerme. Neue Chancen fuer Stadtwerke. Rahmenbedingungen fuer den Waermemarkt

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Michael [K.Group GmbH, Muenchen (Germany). Bereich Nachhaltige Energieversorgung und Stadtentwicklung

    2009-06-15

    In the regulated market, municipal utilities are forced to find new fields of activity. The heat market offers good chances. For example, local district heating grids can be established, independent power generation can be encouraged, and new services can be offered which may increase customer loyalty. The district heating initiative of the Baden-Wuerttemberg Minister of the Environment was launched early in 2009 with the intention to offer valuable assistance to the municipal utilities. (orig.)

  6. Combined Heat and Power Dispatch Considering Heat Storage of Both Buildings and Pipelines in District Heating System for Wind Power Integration

    Directory of Open Access Journals (Sweden)

    Ping Li

    2017-06-01

    Full Text Available The strong coupling between electric power and heat supply highly restricts the electric power generation range of combined heat and power (CHP units during heating seasons. This makes the system operational flexibility very low, which leads to heavy wind power curtailment, especially in the region with a high percentage of CHP units and abundant wind power energy such as northeastern China. The heat storage capacity of pipelines and buildings of the district heating system (DHS, which already exist in the urban infrastructures, can be exploited to realize the power and heat decoupling without any additional investment. We formulate a combined heat and power dispatch model considering both the pipelines’ dynamic thermal performance (PDTP and the buildings’ thermal inertia (BTI, abbreviated as the CPB-CHPD model, emphasizing the coordinating operation between the electric power and district heating systems to break the strong coupling without impacting end users’ heat supply quality. Simulation results demonstrate that the proposed CPB-CHPD model has much better synergic benefits than the model considering only PDTP or BTI on wind power integration and total operation cost savings.

  7. Public sector district health system: Is seven to ten minutes enough ...

    African Journals Online (AJOL)

    The development of a municipality based district health system has created an opportunity to practice family medicine in Mitchells Plain, but lack of clinical time to practice family medicine in the current setting raises questions about the quality and efficiency of primary health care in the municipality based district based ...

  8. How low can the low heating load density district heating be? Environmental aspects on low heating load density district heating of the present generation compared to a domestic oil burner; Hur vaermegles kan den vaermeglesa fjaerrvaermen vara? Miljoeaspekter paa vaermegles fjaerrvaerme med dagens teknik jaemfoerd med villaoljepanna

    Energy Technology Data Exchange (ETDEWEB)

    Froeling, Morgan [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Chemical Environmental Science

    2005-07-01

    In Sweden we can see an increase of district heating networks in residential areas with low heat density. For the customer the economy is normally the most important argument when deciding to choose district heating. For many customers, however, arguments regarding environmental friendliness are important complimentary arguments. When district heating systems are built with decreased heat density, the environmental impacts from use of district heating will increase, depending on such as increased need of pipes and increased heat losses from the distribution system. The purpose of this study is to investigate if there is a limit, a lowest heat density when it is not any longer beneficial to build district heating when district heating replaces local oil furnace heating. Life cycle inventory data for district heating distribution systems in areas with low heat density has been compared with the use of oil furnaces. The environmental impacts are categorized into Global Warming Potential, Acidification Potential, Eutrofication Potential and Use of Finite Resources. To enhance the assessment three single point indicators have also been used: EcoIndicator99, EPS and ExternE. The economics of using district heating in areas with low heat density has not been regarded in this study. A model comparing the space heating of a single family home with an oil furnace or with district heating has been created. The home has an annual heat need of 20 MWh. The district heating distribution network is characterized by its linear heat density. The linear heat density is a rough description of a district heating network, and thus also the results from the model will be general. Still it can give us a general idea of the environmental limit for district heating in areas with low heat density. An assessment of all results indicate that with the type of technology used at present it is not environmentally beneficial to use district heating with lower linear heat density than 0,2 MWh/m. At

  9. Comparing the value of bioenergy in the heating and transport sectors of an electricity-intensive energy system in Norway

    International Nuclear Information System (INIS)

    Assefa Hagos, Dejene; Gebremedhin, Alemayehu; Folsland Bolkesjø, Torjus

    2015-01-01

    The objective of this paper is to identify the most valuable sector for the use of bioenergy in a flexible energy system in order to meet the energy policy objectives of Inland Norway. A reference system was used to construct alternative systems in the heating and transport sectors. The alternative system in the heating sector is based on heat pumps and bio-heat boilers while the alternative systems in the transport sector are based on three different pathways: bio-dimethyl ether, hydrogen fuel cell vehicles and battery electric vehicles. The alternative systems were compared with the reference system after a business-economic optimisation had been made using an energy system analysis tool. The results show that the excess electricity availability due to increased energy efficiency measures hampers the competitiveness and penetration of bio-heating over heat pumps in the heating sector. Indeed, the synergy effect of using bio-dimethyl ether in the transport sector for an increased share of renewable energy sources is much higher than that of the hydrogen fuel cell vehicle and battery electric vehicle pathways. The study also revealed that increasing renewable energy production would increase the renewable energy share more than what would be achieved by an increase in energy efficiency. -- Highlights: •Bio-heating is less competitive over heat pump for low quality heat production. •Renewable energy production meets policy objectives better than system efficiency. •Bioenergy is more valuable in the transport sector than the heating sector

  10. Study and optimization of operating regimes of NPP district heating system

    International Nuclear Information System (INIS)

    Bunin, V.S.; Vasil'ev, M.K.; Kudryavtsev, A.A.; Gorbashev, Yu.B.; Gadzhij, V.M.

    1980-01-01

    Thermal tests of the system with two reactors and four turbines have been carried out for the purpose of verification of operating regimes of the NPP district heating system with boiling single-curcuit RBMK-1000 reactors and K-500-65/3000 turbines. The system is designed for heat supply of habitable settlement and industrial site. The data processing have been carried out by the BESM-6 computer representing distributions of heat flow, steam, water and their parameters and determining the main energy indices of the system. Calculations of the system operating regime variables during the year have been carried out with the help of this program. It has been expected that the system provided heat consumption of 232 MW at calculated regime of thermal loading of the district, temperature regime of the system water of 130/170 deg C, relative load of hot water supply of 0.2 and duration of heating period of 4800 h. Calculations demonstrated that distric heat supply by NPP allowed one to supplant about 85 thous. of reference fuel/year of organic fuel. About 63 thous. of reference fuel/year are required for compensation of decrease of electric energy production in a condensation cycle. It has been also shown, that replacing the four-stroke system heaters by one-stroke heaters permits to drop system water underheating 1.5 times and, respectively, electric energy underproduction to 72 mln Mj (20 mln, kWxh). It produces additional economy of 6.6 thous. reference fuel/year. Calculations of its heat system have been conducted in order to determine the influence of water consumption in an intermediate circuit on the system efficiency. It has been shown that with the increase of water consumption energy power losses decrease. Thus, the above studied have demonstrated that the use of the single-circuit NPP district heating systems leads to considerable economy of fuel

  11. Method and means for heating buildings in a district heating system with waste heat from a thermal power plant

    International Nuclear Information System (INIS)

    Margen, P.H.E.

    1975-01-01

    The waste heat from a thermal power plant is transported through a municipal heating network to a plurality of buildings to be heated. The quantity of heat thus supplied to the buildings is higher than that required for the heating of the buildings. The excess heat is released from the buildings to the atmosphere in the form of hot air

  12. IRP applied to district heating in Eastern Europe

    Energy Technology Data Exchange (ETDEWEB)

    Bull, M. [USDOE Bonneville Power Administration, Portland, OR (United States); Secrest, T. [Pacific Northwest Lab., Richland, WA (United States); Zeman, J. [Czech Energy Efficiency Center (SEVEn) (Czech Republic); Popelka, A. [TECOGEN, Inc., Waltham, MA (United States)

    1994-08-01

    The cities of Plzen, Czech Republic, and Handlova, Republic of Slovakia, are examining options for meeting the thermal energy requirements of their citizens with consideration of both economics and the environment. Major energy related issues faced by the cities are: the frequent need to replace and/or implement a major rehabilitation of the central heating plants and the transmission and distribution systems that supply the consumers; and the need to reduce emissions in order to comply with more stringent environmental regulations and improve air quality; and the need to minimize consumer energy bills, particularly to accommodate the upcoming decontrol of energy prices and to minimize non-payment problems. The intent of the integrated resource planning (IRP) projects is to present analyses of options to support the cities` decision-making processes, not to provide specific recommendations or guidance for the cities to follow.

  13. Thermal performance of solar district heating plants in Denmark

    DEFF Research Database (Denmark)

    Furbo, Simon; Perers, Bengt; Bava, Federico

    2014-01-01

    collectors mounted on the ground, shows measured yearly thermal performances of the solar heating plants placed in the interval from 313 kWh/m² collector to 493 kWh/m² collector with averages for all plants of 411 kWh/m² collector for 2012 and 450 kWh/m² collector for 2013. Theoretical calculations show...... that for temperature levels higher than about 55°C the thermal performance of a solar collector field based on concentrating tracking solar collectors is higher than the thermal performance of a solar collector field based on flat plate collectors. It is estimated that there are potentials for further improvements...... by parallel theoretical and experimental approach to investigate in detail the thermal performance of differently designed solar collector fields in such a way that their thermal performance can be determined by theoretical calculations in the future. This will be useful in connection with development...

  14. Economic consequences of extra by-passes in district heating networks. Investment-, running- and maintenance costs

    International Nuclear Information System (INIS)

    Herbert, P.

    1995-02-01

    For various reasons, extra by-passes are installed in district heating networks to ensure a high flow temperature when the water circulation is insufficient. By 'extra by-pass' we here mean a connection between the distribution pipe and the return pipe. This study mainly deals with extra by-passes to prevent freezing. The estimation of the extra by-pass costs is based on the district heating rates. Our assumption is that an extra by-pass can be regarded as a substation in the district heating network, with regard to the demand for the water flow, heat and power. The reason is the difficulty to obtain available facts to estimate the real costs concerning extra by-passes. Therefore, the method can not claim that the information about the costs is exact but gives an indication of the size of them. The valves in an extra by-pass can be set more or less open. We assume that manual valves in extra by-passes are wide open. Thermostatic valves are, however, assumed to be adjusted in order to cause a very small water flow. 2 refs, 16 figs, 9 tabs, 6 appendices

  15. Effect of Design Static Pressure Level on Energy Efficiency at Low Energy District Heating Systems

    DEFF Research Database (Denmark)

    Tol, Hakan; Svendsen, Svend

    2012-01-01

    Low-Energy District Heating (DH) systems with low-temperature operations, such as 55 °C in terms of supply and 25 °C in terms of return, were considered to be the 4th generation of the DH systems for the low-energy future with energy efficiencies focused to be achieved at newly built and existing...... buildings by the Danish building regulations. Therefore focus has been given to reduce the heat demand of the consumer site with integration of low-energy buildings, to be considered for new settlements and with renovation of existing buildings to low-energy class. The reduction of heat demand increases...... the ratio of heat loss from the DH network in comparison to the heat supplied to the district. In our former studies, the low-energy DH system was optimized with the aim of reducing the heat loss from the low-energy DH network in a certain limit of static pressure level of 10 bara. Thus, in this present...

  16. Istra district heating system. Specific technical report. Appendix 2 to the master plan

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-09-01

    The objective of the master plan project is to improve heat supply in Istra. The considerable system losses from the fuel supplied to the end-users are one subject for improvement. At the same time, the current system operation results in poor quality heat for the consumers. Due to the inflexibility of the system, the dwellings/premises of the consumers are either overheated or insufficiently heated. The financial situation in Istra, the legal ownership of the district heating system and consumers ability to pay limit the possibilities for system improvements. The Master Plan and Feasibility Study evaluates four different development scenarios. Each of the scenarios is compared to the current situation in Istra, where nothing is done to change the system, but only to operate the present system in a sustainable way. The sustainable operation of the district heating system includes all necessary renovations and component replacements necessary. The project does not take into account the present financial situation in Istra, which has resulted in less maintenance than necessary. This situation is not a comparable parameter, as it is not sustainable and will lead to a breakdown of the heat supply within a short time horizon. (EHS)

  17. Geothermal energy potential for district and process heating applications in the U. S. : an economic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bloomster, C.H.; Fassbender, L.L.; McDonald, C.L.

    1977-08-01

    Geothermal energy is competitive for space and process heating applications over significant distances when employed on a large scale to serve concentrated markets. Under these conditions geothermal energy from 90 to 150/sup 0/C hydrothermal resources should be economically competitive for high-density urban district heating out to distances of 50 miles from the wellhead. Supply curves (price-quantity relationships) were developed for both process heating and district heating applications for distances out to 50 miles. The 90 to 150/sup 0/C hydrothermal resources, which were identified in the assessment of geothermal resources by the U.S. Geological Survey, contain usable energy for space and process heat equivalent to 50 billion barrels of oil. The potential demand for space and process heat near these hydrothermal resources is large; over 10% of the U.S. population resides within 40 miles of the resources. The sensitivity of production costs to the important factors of production was determined. The most important factors are well costs, well flow rate, resource temperature, distance separating demand and supply, population density, size of demand, and the system load factor. Technological advances are needed to reduce costs and increase the distances over which geothermal energy can be competitive. Institutional deterrents to widespread nonelectric applications of geothermal energy will probably be significant. Among these will be the acquisition of rights-of-way, the need to organize concentrated markets, and price competition from the conventional fuels based on average cost rather than marginal cost.

  18. Thermal performances of a "black box" heat exchanger in district heating system

    Science.gov (United States)

    Genić, Srbislav B.; Jaćimović, Branislav M.; Milovančević, Uroš M.; Ivošević, Miloš M.; Otović, Milena M.; Antić, Milan I.

    2018-03-01

    The procedure for field testing of plate heat exchanger, considered as a black box, is presented in the paper. After the field measurements have been conducted, simple but unambiguous procedure has been used to establish heat performance parameters including the heat duty and fouling factor. Advantage of hereby presented method is that it can be used for analysis of any other similar heat transfer equipment.

  19. Developing a strategy for improving efficiency in the heating sector in central and eastern Europe

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, A.S. [World Bank, Washington, DC (United States)

    1995-12-31

    Heating is a vital energy service in Central and Eastern Europe, but the current delivery mechanisms are riddled with problems. District heating (DH) in its present technical form and with the present management structures is an inefficient system which produces expensive heat. Customers cannot control it and react to overheating by opening windows, even in winter. DH facilities together with other forms of individual heating are responsible for air pollution, causing severe impacts on the health of urban residents. The issues relating to DH are discussed, the first World Bank activities and experiences with projects in Poland are analyzed, and the cornerstones of a strategy to support future World Bank financing and the development of sound heating policies in CEE are presented.

  20. The TX-model - a quantitative heat loss analysis of district heating pipes by means of IR surface temperature measurements

    Energy Technology Data Exchange (ETDEWEB)

    Zinki, Heimo [ZW Energiteknik, Nykoeping (Sweden)

    1996-11-01

    The aim of this study was to investigate the possibility of analysing the temperature profile at the ground surface above buried district heating pipes in such a way that would enable the quantitative determination of heat loss from the pair of pipes. In practical applications, it is supposed that this temperature profile is generated by means of advanced IR-thermography. For this purpose, the principle of the TX - model has been developed, based on the fact that the heat losses from pipes buried in the ground have a temperature signature on the ground surface. Qualitative analysis of this temperature signature is very well known and in practical use for detecting leaks from pipes. These techniques primarily make use of relative changes of the temperature pattern along the pipe. In the quantitative heat loss analysis, however, it is presumed that the temperature profile across the pipes is related to the pipe heat loss per unit length. The basic idea is that the integral of the temperature profile perpendicular to the pipe, called TX, is a function of the heat loss, but is also affected by other parameters such as burial depth, heat diffusivity, wind, precipitation and so on. In order to analyse the parameters influencing the TX- factor, a simulation model for the energy balance at the ground surface has been developed. This model includes the heat flow from the pipe to the surface and the heat exchange at the surface with the environment due to convection, latent heat change, solar and long wave radiation. The simulation gives the surprising result that the TX factor is by and large unaffected during the course of a day even when the sun is shining, as long as other climate conditions are relatively stable (low wind, no rain, no shadows). The results from the simulations were verified at different sites in Denmark, Finland, Sweden and USA through a co-operative research program organised and partially financed by the IEA District Heating Programme, Task III, and

  1. Study of methanization resource and potential development in Aquitaine - Technical report. To keep on developing the methanization sector in the Dordogne district

    International Nuclear Information System (INIS)

    Priarollo, Jeremie; Michels, Julie; Jimenez, Julien

    2015-05-01

    This study aims at characterising territories of the Aquitaine region in terms of potential of development of individual, collective and territorial methanization units. The territory organic resource potential has first been assessed, and then combined with energetic outlets for biogas and outlets for digestates. A first phase aimed at providing a situational analysis of the methanization sector in the region. During a second phase, different resources of mobilisable organic wastes have been quantified, characterised and mapped at the district level in combination with energetic outlets (gas and heat) and digestate outlets. A third phase aimed at identifying and characterising areas of the different districts of the region displaying a methanization potential. After this report, a set of Power Point presentations is proposed which present this study under another form. Thus, these presentations contain graphs and data which illustrate these different aspects and issues: presentation of the different methanizable resources (quantitative results and maps), energy valorisation potential (co-generation and thermal outlets, injection into natural gas networks, definition and characterisation of areas displaying an interesting potential), presentation of a regional support arrangement (Methaqtion)

  2. District heating systems between competition protection and climate protection; Die Fernwaermenetze zwischen Wettbewerbs- und Klimaschutz

    Energy Technology Data Exchange (ETDEWEB)

    Koerber, Torsten [Goettingen Univ. (Germany). Lehrstuhl fuer Buergerliches Recht, Kartellrecht, Versicherungs-, Gesellschafts- und Regulierungsrecht

    2012-10-15

    In principle, district heating systems come in the application area of paragraph 19 sect. 4 no. 4 GWB (law against competitive restrictions). However, this regulation has to be interpreted with respect to the legislation of the Court of Justice of the European Union (Luxemburg) to 'essential facilities'. According to this, the claim for antitrust access can be affirmed only in exceptional circumstances. Within the application of this regulation, property rights, competition protection, investment competition, innovation competition as well as energy political evaluations of the energy law under special consideration of ecologic and climate political targets are considered. This has to occur within the testing of the reasonability with respect to paragraph 19 sect. 4 no. 2 GWB. The particularities of the district heating.

  3. Plug and Play Process Control Applied to a District Heating System

    DEFF Research Database (Denmark)

    Knudsen, Torben; Trangbæk, Klaus; Kallesøe, Carsten Skovmose

    2008-01-01

    The general ideas within plug and play process control (PTC) are to initialize and reconfigure control systems just by plug and play. In this paper these ideas are applied to a district heating pressure control problem. First of all this serves as a concrete example of PTC, secondly some of the f...... of the first techniques developed in the project to solve the problems in PTC are presented. These are in the area of incremental modelling and control and they make it possible to "plug'' in a new sensor and actuator and make it "play'' automatically.......The general ideas within plug and play process control (PTC) are to initialize and reconfigure control systems just by plug and play. In this paper these ideas are applied to a district heating pressure control problem. First of all this serves as a concrete example of PTC, secondly some...

  4. District heat, energy for fore-sighted people. Proceedings; Energie fuer Menschen mit Weitblick. Vortragsband

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The proceedings volume contains a great part of the papers presented, but some are represented only by copies of the overheads which accompanied the papers. The lecture meeting was devoted to the following major topics: Economical and safe supply of district heat, outlook on the future of the district heat supply industry in a liberalized market, customer relationship management taking into account contracting, information and communication via call centers, and other forms of guidance for decision making.(GL) [German] Vortraege vorliegend teils als Manuskript, teils als Folien mit folgenden Schwerpunkten: Die wirtschaftliche und sichere Versorgung durch Fernwaerme, die Zukunft der Fernwaerme im liberalisierten Markt, der Weg zum Kunden im Hinblick auf Contracting, Kommunikation, Betreuung sowie Beratung und Entscheidungsfindung.(GL)

  5. District heating/cogeneration application studies for the Minneapolis-St Paul area. Executive summary; overall feasibility and economic viability for a district heating/new cogeneration system in Minneapolis-St. Paul

    Energy Technology Data Exchange (ETDEWEB)

    Margen, P.; Larsson, K.; Cronholm, L.A.; Marklund, J.E.

    1979-08-01

    A study was undertaken to determine the feasibility of introducing a large-scale, hot-water, district-heating system for the Minneapolis-St. Paul area. The analysis was based on modern European hot-water district-heating concepts in which cogeneration power plants supply the base-load thermal energy. Heat would be supplied from converted turbines of existing coal-fired power plants in Minneapolis and St. Paul. Toward the end of the 20-year development period, one or two new cogeneration units would be required. Thus, the district-heating system could use low-grade heat from either coal-fired or nuclear cogeneration power stations to replace the space-heating fuels currently used - natural gas and distillate oil. The following conclusions can be drawn: the concept is technically feasible, it has great value for fuel conservation, and with appropriate financing the system is economically viable.

  6. Optimized district heating supply temperature for large networks; Optimerad framledningstemperatur foer stora fjaerrvaermenaet

    Energy Technology Data Exchange (ETDEWEB)

    Saarinen, Lisa; Boman, Katarina

    2012-02-15

    The supply temperature of the Uppsala district heating network was optimized using a model-based control strategy. Simulation of the network showed that the supply temperature could be decreased by in average 8 deg and the electricity production of the plants supplying the network could be increased with 2.5 % during the period January- April, giving an extra income of 1.2 MSEK due to increased income from electricity sales

  7. Regional Energy Planning Tool for Renewable Integrated Low-Energy District Heating Systems

    DEFF Research Database (Denmark)

    Tol, Hakan; Dincer, Ibrahim; Svendsen, Svend

    2013-01-01

    Low-energy district heating systems, operating at low temperature of 55 °C as supply and 25°C as return, can be the energy solution as being the prevailing heating infrastructure in urban areas, considering future energy schemesaiming at increased exploitation of renewable energy sources together...... studies, one being Greater Copenhagen Area and the other Greater Toronto Area, in accordance with  various climate conditions and available resources in these locations, CO2 emission savings obtained with up to 880 and1,400 M tons, respectively....

  8. An application of data mining in district heating substations for improving energy performance

    Science.gov (United States)

    Xue, Puning; Zhou, Zhigang; Chen, Xin; Liu, Jing

    2017-11-01

    Automatic meter reading system is capable of collecting and storing a huge number of district heating (DH) data. However, the data obtained are rarely fully utilized. Data mining is a promising technology to discover potential interesting knowledge from vast data. This paper applies data mining methods to analyse the massive data for improving energy performance of DH substation. The technical approach contains three steps: data selection, cluster analysis and association rule mining (ARM). Two-heating-season data of a substation are used for case study. Cluster analysis identifies six distinct heating patterns based on the primary heat of the substation. ARM reveals that secondary pressure difference and secondary flow rate have a strong correlation. Using the discovered rules, a fault occurring in remote flow meter installed at secondary network is detected accurately. The application demonstrates that data mining techniques can effectively extrapolate potential useful knowledge to better understand substation operation strategies and improve substation energy performance.

  9. Operational Planning of Low-Energy District Heating Systems Connected to Existing Buildings

    DEFF Research Database (Denmark)

    Tol, Hakan; Svendsen, Svend

    2012-01-01

    This article focuses on low-energy District Heating (DH) systems operating in low-temperatures such as 55°C in terms of supply and 25°C in terms of return in connection with existing buildings. Since the heat loss from the network has a significant impact in case of supplying heat to low....... The response of the radiator heating systems at different levels of supply temperature was used to form the operational planning of the low-energy DH system, which determined the design parameters of the low-energy DH network in terms of overall mass flow requirement and the return temperature from...... the buildings. Since the existing buildings were considered to be renovated to low-energy class, the operational planning was simultaneously modelled for both present high-demand and future low-demand situations of the same case area....

  10. Low-energy district heating in energy-efficient building areas

    DEFF Research Database (Denmark)

    Dalla Rosa, Alessandro; Christensen, Jørgen Erik

    2011-01-01

    This paper presents an innovative low-energy district heating (DH) concept based on low-temperature operation. The decreased heating demand from low-energy buildings affects the cost-effectiveness of traditionally-designed DH systems, so we carried out a case study of the annual energy performance...... design, and operational temperature and pressure. In the north-European climate, we found that human behaviour can lead to 50% higher heating demand and 60% higher heating power than those anticipated in the reference values in the standard calculations for energy demand patterns in energy...... system that fully relies on renewable energy needs substantial capital investment, but in the long term this is sustainable from the environmental and socio-economic points of view. Having demonstrated the value of the low-energy DH concept, we evaluated various possible designs with the aim of finding...

  11. District heating system of Belgrade supplied from the co-generation plant 'Obrenovac' (Yugoslavia)

    International Nuclear Information System (INIS)

    Tomic, P.; Dobric, Z.; Studovic, M.

    2000-01-01

    The paper presents most relevant technical and economic features of the Project called 'System for supplying Belgrade with heat' (SDGB) from the thermal power plant 'Obrenovac', based on domestic coal and reconstruction of condensing power plant for combined generation of electricity and heat for the needs of municipal energy consumption. The system is designed for transport thermal energy, with capacity of 730 MJ/s from the Thermal Power Plant 'Nikola Tesla' / A to the existing heat plant 'Novi Beograd' based on the natural gas. The paper also gives the comparison of most important technical and economic features of 'SDGB' Project with the similar Project of District Heating System for supplying Prague with the thermal energy from Thermal Power Plant Melnik. (Author)

  12. Design of a low temperature district heating network with supply recirculation

    DEFF Research Database (Denmark)

    Li, Hongwei; Dalla Rosa, Alessandro; Svendsen, Svend

    2010-01-01

    The focus on continuing improving building energy efficiency and reducing building energy consumption brings the key impetus for the development of the new generation district heating (DH) system. In the new generation DH network, the supply and return temperature are designed low in order to sig...... calculates the heat loss in the twin pipe as that in the single pipe. The influence of this simplification on the supply/return water temperature prediction was analyzed by solving the coupled differential energy equations.......The focus on continuing improving building energy efficiency and reducing building energy consumption brings the key impetus for the development of the new generation district heating (DH) system. In the new generation DH network, the supply and return temperature are designed low in order...... to significantly reduce the network heat loss. Meanwhile, the low network operational temperature can make a better utilization of renewable energy and further improve the CHP plant efficiency. Though the designed return temperature is low, it may increase considerably when the heating load becomes low and the by...

  13. Application of Service Oriented Architecture for Sensors and Actuators in District Heating Substations

    Science.gov (United States)

    Gustafsson, Jonas; Kyusakov, Rumen; Mäkitaavola, Henrik; Delsing, Jerker

    2014-01-01

    Hardwired sensor installations using proprietary protocols found in today's district heating substations limit the potential usability of the sensors in and around the substations. If sensor resources can be shared and re-used in a variety of applications, the cost of sensors and installation can be reduced, and their functionality and operability can be increased. In this paper, we present a new concept of district heating substation control and monitoring, where a service oriented architecture (SOA) is deployed in a wireless sensor network (WSN), which is integrated with the substation. IP-networking is exclusively used from sensor to server; hence, no middleware is needed for Internet integration. Further, by enabling thousands of sensors with SOA capabilities, a System of Systems approach can be applied. The results of this paper show that it is possible to utilize SOA solutions with heavily resource-constrained embedded devices in contexts where the real-time constrains are limited, such as in a district heating substation. PMID:25196165

  14. Application of service oriented architecture for sensors and actuators in district heating substations.

    Science.gov (United States)

    Gustafsson, Jonas; Kyusakov, Rumen; Mäkitaavola, Henrik; Delsing, Jerker

    2014-08-21

    Hardwired sensor installations using proprietary protocols found in today's district heating substations limit the potential usability of the sensors in and around the substations. If sensor resources can be shared and re-used in a variety of applications, the cost of sensors and installation can be reduced, and their functionality and operability can be increased. In this paper, we present a new concept of district heating substation control and monitoring, where a service oriented architecture (SOA) is deployed in a wireless sensor network (WSN), which is integrated with the substation. IP-networking is exclusively used from sensor to server; hence, no middleware is needed for Internet integration. Further, by enabling thousands of sensors with SOA capabilities, a System of Systems approach can be applied. The results of this paper show that it is possible to utilize SOA solutions with heavily resource-constrained embedded devices in contexts where the real-time constrains are limited, such as in a district heating substation.

  15. Heating and Domestic Hot Water Systems in Buildings Supplied by Low-Temperature District Heating

    DEFF Research Database (Denmark)

    Brand, Marek

    leads to up to 56% greater heat demand than values suggested in the Danish national calculation tool Be10, and in 40% lower connection power than for an SH system dimensioned in accordance with DS 418. Use of Be10 input data in cost-effectiveness analyses for DH networks therefore means worse results......, because less heat is sold to customers and there is higher heat loss in the network. Similarly, higher connection power than needed means bigger pipe diameters are needed, resulting in higher heat losses as well. Using realistic values is therefore very important for feasibility calculations of DH.  ...

  16. Excess heat production of future net zero energy buildings within district heating areas in Denmark

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Möller, Bernd

    2012-01-01

    buildings in Denmark are connected to electricity grids and around half are connected to districtheating (DH) systems. Connecting buildings to larger energy systems enables them to send and receive energy from these systems. This paper’s objective is to examine how excess heat production from NZEBs...... excess heat production from solar thermal collectors. The main findings are that the excess heat from NZEBs can benefit DH systems by decreasing the production from production units utilizing combustible fuels. In DH areas where the heat demand in summer months is already covered by renewable energy...

  17. Multicriteria optimization approach to design and operation of district heating supply system over its life cycle

    Science.gov (United States)

    Hirsch, Piotr; Duzinkiewicz, Kazimierz; Grochowski, Michał

    2017-11-01

    District Heating (DH) systems are commonly supplied using local heat sources. Nowadays, modern insulation materials allow for effective and economically viable heat transportation over long distances (over 20 km). In the paper a method for optimized selection of design and operating parameters of long distance Heat Transportation System (HTS) is proposed. The method allows for evaluation of feasibility and effectivity of heat transportation from the considered heat sources. The optimized selection is formulated as multicriteria decision-making problem. The constraints for this problem include a static HTS model, allowing considerations of system life cycle, time variability and spatial topology. Thereby, variation of heat demand and ground temperature within the DH area, insulation and pipe aging and/or terrain elevation profile are taken into account in the decision-making process. The HTS construction costs, pumping power, and heat losses are considered as objective functions. Inner pipe diameter, insulation thickness, temperatures and pumping stations locations are optimized during the decision-making process. Moreover, the variants of pipe-laying e.g. one pipeline with the larger diameter or two with the smaller might be considered during the optimization. The analyzed optimization problem is multicriteria, hybrid and nonlinear. Because of such problem properties, the genetic solver was applied.

  18. Modeling of District Heating Networks for the Purpose of Operational Optimization with Thermal Energy Storage

    Science.gov (United States)

    Leśko, Michał; Bujalski, Wojciech

    2017-12-01

    The aim of this document is to present the topic of modeling district heating systems in order to enable optimization of their operation, with special focus on thermal energy storage in the pipelines. Two mathematical models for simulation of transient behavior of district heating networks have been described, and their results have been compared in a case study. The operational optimization in a DH system, especially if this system is supplied from a combined heat and power plant, is a difficult and complicated task. Finding a global financial optimum requires considering long periods of time and including thermal energy storage possibilities into consideration. One of the most interesting options for thermal energy storage is utilization of thermal inertia of the network itself. This approach requires no additional investment, while providing significant possibilities for heat load shifting. It is not feasible to use full topological models of the networks, comprising thousands of substations and network sections, for the purpose of operational optimization with thermal energy storage, because such models require long calculation times. In order to optimize planned thermal energy storage actions, it is necessary to model the transient behavior of the network in a very simple way - allowing for fast and reliable calculations. Two approaches to building such models have been presented. Both have been tested by comparing the results of simulation of the behavior of the same network. The characteristic features, advantages and disadvantages of both kinds of models have been identified. The results can prove useful for district heating system operators in the near future.

  19. Modeling of District Heating Networks for the Purpose of Operational Optimization with Thermal Energy Storage

    Directory of Open Access Journals (Sweden)

    Leśko Michał

    2017-12-01

    Full Text Available The aim of this document is to present the topic of modeling district heating systems in order to enable optimization of their operation, with special focus on thermal energy storage in the pipelines. Two mathematical models for simulation of transient behavior of district heating networks have been described, and their results have been compared in a case study. The operational optimization in a DH system, especially if this system is supplied from a combined heat and power plant, is a difficult and complicated task. Finding a global financial optimum requires considering long periods of time and including thermal energy storage possibilities into consideration. One of the most interesting options for thermal energy storage is utilization of thermal inertia of the network itself. This approach requires no additional investment, while providing significant possibilities for heat load shifting. It is not feasible to use full topological models of the networks, comprising thousands of substations and network sections, for the purpose of operational optimization with thermal energy storage, because such models require long calculation times. In order to optimize planned thermal energy storage actions, it is necessary to model the transient behavior of the network in a very simple way - allowing for fast and reliable calculations. Two approaches to building such models have been presented. Both have been tested by comparing the results of simulation of the behavior of the same network. The characteristic features, advantages and disadvantages of both kinds of models have been identified. The results can prove useful for district heating system operators in the near future.

  20. Thermo-economic optimization of a hybrid solar district heating plant with flat plate collectors and parabolic trough collectors in series

    DEFF Research Database (Denmark)

    Tian, Zhiyong; Perers, Bengt; Furbo, Simon

    2018-01-01

    Large-scale solar heating plants for district heating networks have gained great success in Europe, particularly in Denmark. A hybrid solar district heating plant with 5960 m2 flat plate collectors and 4039 m2 parabolic trough collectors in series was built in Taars, Denmark in 2015. The solar...... to optimize the hybrid solar district heating systems based on levelized cost of heat. It is found that the lowest net levelized cost of heat of hybrid solar heating plants could reach about 0.36 DKK/kWh. The system levelized cost of heat can be reduced by 5–9% by use of solar collectors in the district...... heating network in this study. The results also show that parabolic trough collectors are economically feasible for district heating networks in Denmark. The generic and multivariable levelized cost of heat method can guide engineers and designers on the design, construction and control of large...

  1. Space heating with ultra-low-temperature district heating - a case study of four single-family houses from the 1980s

    DEFF Research Database (Denmark)

    Østergaard, Dorte Skaarup; Svendsen, Svend

    2017-01-01

    . These benefits can be maximized if district heating temperatures are lowered as much as possible. In this paper we report on a project where 18 Danish single-family houses from the 1980s were supplied by ultra-low temperature district heating with a supply temperature as low as 45 degrees C for the main part...... heating return temperatures in the houses were analysed for different times of the year. The study found that existing Danish single-family houses from the 1980s can be heated with supply temperatures as low as 45 degrees C for the main part of the year. Both simulation models and test measurements showed...

  2. Minnesota Project: district heating and cooling through power plant retrofit and distribution network. Final report. Phase 1. [Minnesota Project

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-01-01

    Appendices are presented for the Minnesota Project: District Heating and Cooling Through Power Plant Retrofit and Distribution Network. These are: SYNTHA results (SYNTHA II is a proprietary program of the SYNTHA Corporation); Market Survey Questionnaire: Environmental Review Procedures; Public Service Commission Regulation of District Heating; Energy Use Normalization Procedures; Power Plant Description; Letters of Commitment; Bond Opinion and Issuance; and Marvin Koeplin Letter, Chairman of Public Service Commission, Moorehead, Minnesota.

  3. APPLICATION OF DIMENSIONAL ANALYSIS IN HEAT LOSS DETERMINING IN DISTRICT HEATING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Mária Čarnogurská

    2016-04-01

    Full Text Available Existing procedures for determining the heat loss in heat distribution use balance relations, or rather they are based on the theory of heat and mass transfer. Dimensional analysis enables a new point of view that demonstrated the functionality of heat loss from selected physical quantities that contribute to heat loss. The solution provides one complex criterion and four simplex criteria of similarity. Transforming these criteria of similarity leads to the formulation of the functional dependence of only two criteria, on the basis of which the amount of heat loss can be determined. The resulting criterial dependency is simple, and is calculated in this paper for a pipe one meter in longth. The mathematic model for demonstrating the heat loss is of universal validity, and applies to a wide range of piping used for hot water distribution. However, for each nominal diameter of piping it is necessary to take into account the mutual dependency of the dimensionless arguments p5 on p1, the form of which is always different. In the paper, this dependency is demonstrated for two nominal diameters DN65 and DN125.

  4. Exergy performance analysis of the conceptual district energy network system with heat pump

    International Nuclear Information System (INIS)

    Shin, Seung Won; Chung, Ha Seung; Kim, Min Sung

    2014-01-01

    To increase the efficiency of a district heating system, we propose a district energy network concept which combines several heating resources with additional electric heat pump and thermal energy storage. With help of thermal energy storage, a heat pump can be operated at maximum efficiency at all the time. Electricity generated with less CO 2 emission makes the proposed system much more environmentally friendly. Even though the proposed concept can be applied to any given situation, a specific target area was chosen to show the effectiveness of the newly proposed energy network concept more clearly. Several constraints were applied for the selection process and a simplified model used for quantitative comparison between the existing and the developed concept. Exergy analysis showed the increased performance of proposed energy network system. The result showed that the newly proposed concept generates less CO 2 emission by 46% at maximum compared to the existing system. By using additional renewable energy sources, we can reduce CO 2 emission even further

  5. Nuclear source of district heating in the north-east region of Russia

    International Nuclear Information System (INIS)

    Dolgov, V.V.

    1998-01-01

    The operation of the Bilibin Nuclear Co-generation Plant (BNCP) as a local district heating source is reviewed in this paper. Specific features of the BNCP power unit are given with special emphases on the components of the technological scheme, which are involved in the heat production and supply to the consumers. The scheme of steam extraction from the turbine, the flow diagram of steam in the turbine, as well as the three circuit heat removal system are described. The numerical characteristics of the nuclear heat supply system in various operating modes are presented. The real information characterizing current radiological conditions in the vicinity of the heat generation and distribution equipment is also presented in the paper. The BNCP technical and economical characteristics are compared with those of conventional energy sources. Both advantages and some problems revealed during the twenty-year experience of the BNCP nuclear heat utilization are generally assessed. Safety and reliability characteristics of the reactor and the heat supply system are also described. (author)

  6. Environmental considerations for geothermal energy as a source for district heating

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1996-01-01

    Geothermal energy currently provides a stable and environmentally attractive heat source for approximately 20 district heating (DH) systems in the United States. The use of this resource eliminates nearly 100% of the conventional fuel consumption (and, hence, the emissions) of the loads served by these systems. As a result, geothermal DH systems can rightfully claim the title of the most fuel-efficient CH systems in operations today. The cost of producing heat from a geothermal resource (including capitalization of the production facility and cost for pumping) amounts to an average of $1.00 per mission Btu (0.0034 $/kWh). The major environmental challenge for geothermal systems is proper management of the producing aquifer. Many systems are moving toward injection of the geothermal fluids to ensure long-term production.

  7. Efficiency gains in Danish district heating. Is there anything to learn from benchmarking?

    Energy Technology Data Exchange (ETDEWEB)

    Munksgaard, Jesper; Pade, L.-L.; Fristrup, Peter

    2005-10-01

    Facing a market structure of independent heating systems and cost-of-service regulation the regulator considers ways to create incentives for increasing efficiency in heat production. One way is to implement benchmark regulation. The aim of this paper is twofold: (1) To investigate the potential for increasing productivity in Danish district heating production and (2) to examine whether benchmarking has a role to play. Using data envelopment analysis our analyses show that by assuming variable returns to scale a potential exists to reduce production costs by 5-27% depending on the portfolio of inputs and outputs included in the model. Further, our analyses show that the ranking of producers is much dependent on the combination of inputs and outputs included in the model. Therefore, great care should be taken when deciding on the appropriate model to be used when implementing benchmarking as a regulatory mean.

  8. Evaluation of a multiple linear regression model and SARIMA model in forecasting heat demand for district heating system

    International Nuclear Information System (INIS)

    Fang, Tingting; Lahdelma, Risto

    2016-01-01

    Highlights: • Social factor is considered for the linear regression models besides weather file. • Simultaneously optimize all the coefficients for linear regression models. • SARIMA combined with linear regression is used to forecast the heat demand. • The accuracy for both linear regression and time series models are evaluated. - Abstract: Forecasting heat demand is necessary for production and operation planning of district heating (DH) systems. In this study we first propose a simple regression model where the hourly outdoor temperature and wind speed forecast the heat demand. Weekly rhythm of heat consumption as a social component is added to the model to significantly improve the accuracy. The other type of model is the seasonal autoregressive integrated moving average (SARIMA) model with exogenous variables as a combination to take weather factors, and the historical heat consumption data as depending variables. One outstanding advantage of the model is that it peruses the high accuracy for both long-term and short-term forecast by considering both exogenous factors and time series. The forecasting performance of both linear regression models and time series model are evaluated based on real-life heat demand data for the city of Espoo in Finland by out-of-sample tests for the last 20 full weeks of the year. The results indicate that the proposed linear regression model (T168h) using 168-h demand pattern with midweek holidays classified as Saturdays or Sundays gives the highest accuracy and strong robustness among all the tested models based on the tested forecasting horizon and corresponding data. Considering the parsimony of the input, the ease of use and the high accuracy, the proposed T168h model is the best in practice. The heat demand forecasting model can also be developed for individual buildings if automated meter reading customer measurements are available. This would allow forecasting the heat demand based on more accurate heat consumption

  9. A Direct Heat Exchanger Unit used for Domestic Hot Water Supply in a Single-family House Supplied by Low Energy District Heating

    DEFF Research Database (Denmark)

    Brand, Marek; Thorsen, Jan Eric; Svendsen, Svend

    2010-01-01

    on the testing of the dynamic behaviour of an Instantaneous Heat Exchanger Unit(IHEU) designed for DHW heating and space heating in detached family houses supplied by LEDH ensuring an entry-to-substation temperature of 51 °C. We measured the time it takes for the IHEU to produce DHW with a temperature of 42 °C......The increasing number of new and renovated buildings with reduced heating requirements will soon make traditional District Heating (DH) systems uneconomic. To keep DH competitive in the future, the heat loss in DH networks needs to be reduced. One option is to reduce the supply temperature of DH...... as much as possible. This requires a review of the behaviour of the whole domestic hot water (DHW) supply system with focus on the user comfort and overall costs. This paper describes some practical approaches to the implementation of this Low Energy District Heating (LEDH) concept. It reports...

  10. Modelling the Heat Consumption in District Heating Systems using a Grey-box approach

    DEFF Research Database (Denmark)

    Nielsen, Henrik Aalborg; Madsen, Henrik

    2006-01-01

    The heat consumption in a large geographical area is considered together with climate measurements on a single location in the area. The purpose is to identify a model linking the heat consumption to climate and calendar information. The process of building a model is split into a theoretical based...... identification of an overall model structure followed by data-based modelling, whereby the details of the model are identified. This approach is sometimes called grey-box modelling, but the specific approach used here does not require states to be specified. Overall, the paper demonstrates the power of the grey...

  11. Design principles of a simple and safe 200-MW(thermal) nuclear district heating plant

    International Nuclear Information System (INIS)

    Goetzmann, C.; Bittermann, D.; Gobel, A.

    1987-01-01

    Kraftwerk Union AG has almost completed the development of a dedicated 200-MW(thermal) nuclear district heating plant to provide environmentally clean energy at a predictably low cost. The concept can easily be adapted to meet power requirements within the 100- to 500-MW(thermal) range. This technology is the product of the experience gained with large pressurized water reactor and boiling water reactor power plants, with respect to both plant and fuel performance. The major development task is that of achieving sufficiently low capital cost by tailoring components and systems designed for large plants to the specific requirements of district heating. These requirements are small absolute power, low temperatures and pressures, and modest load following, all of which result in the characteristics that are summarized. A fully integrated primary system with natural circulation permits a very compact reactor building containing all safety-related systems and components. Plant safety is essentially guaranteed by inherent features. The reactor containment is tightly fitted around the reactor pressure vessel in such a way that, in the event of any postulated coolant leak, the core cannot become uncovered, even temporarily. Shutdown is assured by gravity drop of the control rods mounted above the core. Decay heat is removed from the core by means of natural circulation via dedicated intermediate circuits of external aircoolers

  12. Cost of district heating using geothermal energy; Ist geothermische Waerme wirtschaftlich?

    Energy Technology Data Exchange (ETDEWEB)

    Oppermann, G. [GRUNEKO AG, Ingenieure fuer Energiewirtschaft, Basel (Switzerland)

    1997-12-01

    The environmental advantages of a district heating network using geothermal energy are obvious. On the other hand utilizing geothermal energy is considered to be very expensive. The goal of this paper is to compare the costs of geothermal energy with other renewable energy sources. Based on the costs of realized plants and projects the following energy sources have been analysed. Geothermal energy, water of tunnel-drainage, waste heat of a sewage disposal platn and waste wood. All plants have a district heating network. The results are a contribution to the actuel discussion about public subsiding of geothermal energy. (orig.) [Deutsch] Die oekologischen Vorteile einer geothermischen Fernwaermeversorgung sind fuer jeden, der Bohrungen in Erwaegung zieht, unschwer erkennbar. Wie steht es aber mit den Kosten einer geothermischen Nutzung? Hier beleben Horrorzahlen wie auch Wunschdenken die Diskussionen. Der Artikel beabsichtigt einen sachlichen Beitrag zu dieser Diskussion uz liefern. Konkrete Bauprojekte im Megawattbereich der GRUNEKO AG werden kostenmaessig nach gleichen Kriterien analysiert und verglichen. Auf goethermischer Seite wird ein Doublettensystem und eine Tunnelwasserwaermenutzung kostenmaessig analysiert. Als Quervergleich werden ebenfalls GRUNEKO-Projekte mit regenerierbaren Energietraegern herangezogen (Holzschnitzelanlage, Klaeranlagenabwaerme, Seewasser-Abkuehlung). Alle Analgen haben Waermeverteilnetze. Die nachgewiesenen Kostendifferenzen zwischen Geothermie und anderen regenerativen Waermversorgungen koennten einen Beitrag leisten zu der gegenwaertig aktuellen `Ueberpruefung staatlicher Foerderungsmassnahmen zugunsten einer verstaerkten Nutzung der Geothermie`. (orig.)

  13. Technoeconomic analysis of a biomass based district heating system. Paper no. IGEC-1-ID01

    International Nuclear Information System (INIS)

    Zhang, H.; Ugursal, V.I.; Fung, A.

    2005-01-01

    District energy systems (DES) that produce steam, hot water or chilled water at a central plant and then distribute that energy to buildings in the district for space heating, domestic hot water heating and air conditioning provide opportunities for increasing energy efficiency and reducing greenhouse gas (GHG) emissions. Use of biomass, such as wood, wood byproducts and wastes, fast-growing trees, agricultural crops and waste, in place of conventional fossil fuels to produce the thermal energy needed by a DES, presents further opportunities for reducing green house gas emissions as well as providing rural employment, and local solutions to rural and remote energy needs. In this paper, a technoeconomic analysis of a biomass based DES for a community center in Nova Scotia, Canada is presented. The methodology used to size and design the heating and ventilating system, as well as the biomass based DES is discussed. Annual energy requirement and biomass fuel consumption predictions are presented along with cost estimates. A comparative assessment of the economic feasibility of the system vis-a-vis a conventional oil fired system is conducted. While the results are specific to the particular application, the design and analysis methodology that is presented in the paper can be used for any similar application. (author)

  14. District Heating using a gas-motor-driven heat pump - result checking; Erfolgskontrolle. Heizzentrale mit indirekter Gasmotor-Waermepumpe. Berufsschulen Bern-Lorraine

    Energy Technology Data Exchange (ETDEWEB)

    Eggen, B.; Lanz, S.

    2003-07-01

    This final report for the Swiss Federal Office of Energy presents the results of a project that evaluated the operation of a district heating scheme that supplies various school and college buildings, residential buildings and Berne's Botanical Gardens with heat. This pilot and demonstration system comprises an indirect gas motor heat pump with co-generation unit and an electrically-driven heat pump. In order to achieve a high performance ratio the co-generation unit was additionally equipped with a heat-recovery heat pump which condenses the waste gas and recovers radiation heat losses. The implementation of the district heating project was done in stages to meet annual heat demands of around 6'500 MWh. About 50% of these demands are met by the indirect gas motor heat pump. Figures are presented on the optimisation of heat utilisation from ground water which permitted an improvement in the total efficiency of the plant of around 30% compared with a conventional installation. The authors state that, with this installation, it could be demonstrated in an exemplary fashion that heat pumps can also be installed in existing, non-renovated buildings. In the planning of such heat pump systems they recommend that special attention be paid to the overall performance ratio, and that the rate of flow of the heat source and system temperatures be taken into account.

  15. Changes in heat load profile of typical Danish multi-storey buildings when energy-renovated and supplied with low-temperature district heating

    DEFF Research Database (Denmark)

    Harrestrup, Maria; Svendsen, Svend

    2013-01-01

    Denmark has a long-term objective of being free of fossil fuels by 2050, with the energy supply mix for buildings being fossil-free by 2035. Energy consumption for existing buildings needs to be decreased concurrent with the conversion from fossil-fuel supply to renewable-energy (RE) supply. When...... end-use savings are implemented in buildings concurrent with the application of low-temperature district heating (LTDH), the heat profiles of the buildings will change. Reducing peak loads is important, since this is the dimensioning foundation for future district heating systems. To avoid oversized...

  16. Economic analysis of exergy efficiency based control strategy for geothermal district heating system

    International Nuclear Information System (INIS)

    Keçebaş, Ali; Yabanova, İsmail

    2013-01-01

    Highlights: • The ExEBCS for exergy efficiency maximization in real GDHS is economically evaluated. • The initial cost for ExEBCS is more expensive than that for old one by 6.33 kUS$/year. • The cost saving makes the ExEBCS profitable by up to 7% of annual energy saving. • This results in a short payback period of 3.8 years. • The use of newly ExEBCS in GDHSs is quite suitable. - Abstract: In this study, the exergy efficiency based control strategy (ExEBCS) for exergy efficiency maximization in geothermal district heating systems (GDHSs) is economically evaluated. As a real case study, the Afyon GDHS in the city of Afyonkarahisar/Turkey is considered. Its actual thermal data as of average weekly data are collected in heating seasons during the period 2006–2010 for artificial neural network (ANN) modeling. The ANN modeling of the Afyon GDHS is used as a test system to demonstrate the effectiveness and economic impact of the ExEBCS under various operating conditions. Then, the ExEBCS is evaluated economically in case of application to real Afyon GDHS of the ExEBCS. The results show that the initial cost for the ExEBCS is more expensive than that for the old one by 6.33 kUS$/year as a result of replacing automatic controller. The saving in heat production makes the ExEBCS profitable by up to 7% of annual energy saving as a result of the increase in the heat production by 88% when the control system is operated. This results in a short payback period of 3.8 years. This study confirms that the use of ExEBCS in district heating systems (especially GDHS) is quite suitable

  17. Institutional and financial guide to geothermal district heating. Serial No. 2

    Energy Technology Data Exchange (ETDEWEB)

    1982-03-01

    General planning considerations which affect nearly every community are reviewed, and alternative operating structures which are available to communities are reviewed, including local governments, nonprofit cooperatives, private enterprises, and joint ventures. The financing options available to publicly-owned and privately-owned district heating systems are then summarized. The geothermal production and distribution activities most appropriate to each type of operating structure are reviewed, along with typical equity and debt funding sources. The tax advantages for private developers are described, as are the issures of customer contracts and service prices, and customer retrofit financing. The treatment is limited to an introductory overview. (LEW)

  18. French know-how in the field of geothermal energy. District heating and electricity generation systems

    International Nuclear Information System (INIS)

    2012-08-01

    This brochure is aimed at presenting the French expertise, public and private, at international level in the field of geothermal energy (district heating and electricity generation systems). It presents a summary of the French public policy framework, measures to support Research and Development, innovation and training and offers from private companies. It has been designed by the ADEME in cooperation with the French ministry for Ecology and Sustainable Development, the French association of geothermal energy professionals, Ubifrance (the French Agency for international business development) and the French renewable energies union

  19. Institutional and financial guide to geothermal district heating, serial no. 2

    Science.gov (United States)

    1982-03-01

    General planning considerations which affect nearly every community are reviewed, and alternative operating structures which are available to communities are reviewed, including local governments, nonprofit cooperatives, private enterprises, and joint ventures. The financing options available to publicly-owned and privately-owned district heating systems are then summarized. The geothermal production and distribution activities most appropriate to each type of operating structure are reviewed, along with typical equity and debt funding sources. The tax advantages for private developers are described, as are the issues of customer contracts and service prices, and customer retrofit financing. The treatment is limited to an introductory overview.

  20. The strategic role of district heating in renewable energy use; Die strategische Bedeutung der Nahwaerme zur Nutzung erneuerbarer Energien

    Energy Technology Data Exchange (ETDEWEB)

    Nast, M. [Deutsches Zentrum fuer Luft- und Raumfahrt e.V. (DLR), Stuttgart (Germany). Abt. Systemanalyse und Technikbewertung; Boehnisch, H. [Zentrum fuer Sonnenenergie- und Wasserstoff-Forschung Baden-Wuerttemberg (ZSW), Stuttgart (Germany)

    1998-02-01

    District heating allows the utilization of biomass in low emission heating plants, the exploitation of solar energy and the seasonal storage of heat. If a sustainable energy supply system is to be created, district heating must not only be the system of choice for new housing districts but must also be retrofitted in existing settlements. The detailed analysis of a rural community shows that large segments of existing buildings can be connected to district heating systems even in regions with predominantly single dwellings and rural housing densities. The conditions necessary for establishing district heating systems are discussed. (orig.) [Deutsch] Nahwaermesysteme ermoeglichen, fossile und biogene Brennstoffe einzusetzen und lassen sich an saisonale Waermespeicher anschliessen. Zum Aufbau einer nachhaltigen Energieversorgung ist Nahwaerme nicht nur in Neubaugebieten notwendig sondern muss auch in den schon laenger genutzten Gebaeudebestand integriert werden. Das Beispiel einer umfassend analysierten Landgemeinde zeigt, dass ein grosser Teil des bestehenden Gebaeudebestandes an Waermenetze angeschlossen werden kann, selbst bei vorherrschender Bebauung mit Einfamilienhaeusern und laendlichen Gebaeudedichten. Die notwendigen Rahmenbedingungen fuer den Aufbau einer Nahwaermeversorgung werden erlaeutert. (orig.)

  1. An evaluation of the public sector optometric service provided within the health districts in KwaZulu-Natal, South Africa

    Directory of Open Access Journals (Sweden)

    Moraka E. Maake

    2018-04-01

    Full Text Available Background: In South Africa, optometry has been traditionally positioned within the private sector. The situation has gradually changed over the past two decades, with optometry being introduced into the public sector in many parts of the country. Despite the growing numbers, optometrists are still new within the public health sector, motivating this study to evaluate the eye care services they provide. Methods: A cross-sectional, retrospective, descriptive study was undertaken. Stratified random selection was applied to select the study sites, and systematic sampling was used to select patients’ files. A saturated sample of public sector optometrists employed in the selected districts completed study questionnaires. Data were analysed using the Statistical Package for Social Sciences, Version 21. Results: A total of 2968 records were reviewed, and gender distribution was 67.6% female and 32.4% male. Refraction (86.73% was the most frequently conducted test, followed by ophthalmoscopy (74.73%, colour vision (0.07% and gonioscopy (0.03%. The response rate for the questionnaires was 64.7%. Optometric outreach services were conducted by 54.5% of optometrists, and the majority (83.3% reported that the farthest outreach facility was more than 50 km from their base hospital. The availability of equipment at outreach facilities was less as compared to base hospitals, while some reported not having the necessary equipment even at base hospitals. None of the optometrists did contact lens fitting at outreach facilities. A lack of equipment was cited as one of the reasons for not providing this service by 100% of optometrists. Most optometrists (63.6% believed that more than 30% of their referrals might have been avoided if they had prescribed therapeutic agents to manage ocular conditions. Conclusion: Introducing optometrists within the public sector improves access to services for rural communities. However, the minimum standard of optometric care

  2. Choice of insulation standard for pipe networks in 4th generation district heating systems

    DEFF Research Database (Denmark)

    Lund, Rasmus Søgaard; Mohammadi, Soma

    2016-01-01

    and smart gas grids. Improving DH pipes by improving the insulation standard results in decreasing the heat and temperature losses from the pipe networks. When reducing heat losses from DH pipes, there is a trade-off between the increasing cost of pipe insulation and the associated savings in the heat...... by implementing different pipe insulation standards. In the second step, the specific grid losses found in the first step are analysed in an integrated energy systems model where all main energy sectors and their interrelations are included. The outcome of the study can provide decision support when planning...... investments in DH systems today and in the future. The results from the case of Denmark shows that pipes with higher insulation standard (series 3) is generally preferable, but the highest insulation standard available today (series 4) might be preferable in the future if fuel prices or increase or investment...

  3. Measuring and heat losses for district heating systems in detached house areas; Maet- och vaermefoerluster foer fjaerrvaermesystem i smaahusomraaden

    Energy Technology Data Exchange (ETDEWEB)

    Cederborg, Frederick; Nordgren, Ola [FVB Sverige ab, Vaesteraas (Sweden)

    2005-07-01

    Within 'low heat load' areas e.g. residential areas, with low energy consumption per individual customer, the resulting relationship between the heat loss and the energy sales is big. For these customers with low energy consumption, in particular during the summer season, concerns have been raised regarding the ability of the heat volume meters to register the true energy consumption. In order to determine the magnitude of the losses, the Swedish District Heating Association, has initiated a measuring project where measurements have been made in two separate residential areas with different system configurations and different temperature control programs. The measurements were performed from May 15, 2003 to September 23, 2004. The main objective for the project was to gather data and to analyse the magnitude of the total losses in the building systems. The relation between the heat losses and the measuring losses was also studied briefly. Two types of systems have been studied, on one hand a conventional district heating area with primary connected houses and on the other hand an area with secondary connected houses with PEX-pipes in Enkoeping. The heat and measuring losses at the area Munksundet in Enkoeping is 17 % at a 'load density' of 0,84. This value is somewhat lower than the accounted annual relative loss of 22-23 % stated in the report 'FVF 1997:11 Fjaerrvaerme till smaahus'. The results show that a secondary connected low temperature system with PEX-pipes is an interesting connection alternative for small houses. Also at the residential area Rotskaer in Skutskaer, the heat and measuring losses are lower than the accounted annual relative loss, about 24 % at a 'load density' of 0,49,which is to be compared with about 33 % annual relative loss according to the report 'FVF 1997:11'. Within this assignment there are difficulties to divide the measuring losses in short circuit flows and errors in the heat

  4. Steady-state heat losses in pipes for low-energy district heating

    DEFF Research Database (Denmark)

    Dalla Rosa, Alessandro; Li, Hongwei; Svendsen, Svend

    2010-01-01

    of low-energy DH systems. Various design concepts are considered in this paper: flexible pre-insulated twin pipes with symmetrical or asymmetrical insulation, double pipes, triple pipes. These technologies are potentially energyefficient and cost-effective solutions for DH networks in low-heat density...... areas. We start with a review of theories and methods for steady-state heat loss calculation. Next, the article shows how detailed calculations with 2D-modeling of pipes can be carried out by means of computer software based on the finite element method (FEM). The model was validated by comparison...... with analytical results and data from the literature. We took into account the influence of the temperature-dependent conductivity coefficient of polyurethane (PUR) insulation foam, which enabled to achieve a high degree of detail. We also illustrated the influence of the soil temperature throughout the year...

  5. The trigger matters: The decision-making process for heating systems in the residential building sector

    International Nuclear Information System (INIS)

    Hecher, Maria; Hatzl, Stefanie; Knoeri, Christof; Posch, Alfred

    2017-01-01

    As heat demand of buildings accounts for a significant amount of final energy use and related carbon emissions, it’s important to gain insights into the homeowners’ decision-making processes and to identify factors determining the choice of heating systems. In this study, data was collected in an online survey carried out in 2015, from private homeowners of existing and newly built single and double-family houses in Austria who had invested in a new heating system within the last ten years (N=484). In contrast to previous studies, this study specifically investigates the triggers behind homeowner decisions to invest in a new heating system (e.g. problem, opportunity, or new building situation). Results of binary logistic regression analysis show that subsidies for heating system tabinvestments and infrastructural adjustments reveal to be most effective for homeowners in problem situations to foster alternative heating systems. For homeowners in opportunity situations (e.g. building refurbishment), in addition operational convenience appears to be important. For new buildings, the main barriers for alternative heating system adoption were found in the positive perception of fuel supply security and feasibility of fossil systems. Thus, the use of trigger-specific policy measures is proposed to foster alternative heating systems in the residential building sector. - Highlights: • Homeowners’ triggers determine heating system adoption decisions. • It is crucial to reach homeowners early enough to avoid problem situations. • For problem-triggered homeowners, subsidies are most effective. • Opportunity-triggered homeowners prefer alternative heating systems. • Opportunity-triggered homeowners need solid decision basis for technology comparison.

  6. Process of optimization of district heat production by utilizing waste energy from metallurgical processes

    Science.gov (United States)

    Konovšek, Damjan; Fužir, Miran; Slatinek, Matic; Šepul, Tanja; Plesnik, Kristijan; Lečnik, Samo

    2017-07-01

    In a consortium with SIJ (Slovenian Steel Group), Metal Ravne, the local community of Ravne na Koro\\vskem and the public research Institut Jožef Stefan, with its registered office in Slovenia, Petrol Energetika, d.o.o. set up a technical and technological platform of an innovative energy case for a transition of steel industry into circular economy with a complete energy solution called »Utilization of Waste Heat from Metallurgical Processes for District Heating of Ravne na Koro\\vskem. This is the first such project designed for a useful utilization of waste heat in steel industry which uses modern technology and innovative system solutions for an integration of a smart, efficient and sustainable heating and cooling system and which shows a growth potential. This will allow the industry and cities to make energy savings, to improve the quality of air and to increase the benefits for the society we live in. On the basis of circular economy, we designed a target-oriented co-operation of economy, local community and public research institute to produce new business models where end consumers are put into the centre. This innovation opens the door for steel industry and local community to a joint aim that is a transition into efficient low-carbon energy systems which are based on involvement of natural local conditions, renewable energy sources, the use of waste heat and with respect for the principles of sustainable development.

  7. Large heat storage tank for load management nd implementation of ambient heat. District heating networks based on combined heat and power; Grosswaermespeicher zum Lastmanagement und zur Einbindung von Umweltenergie. Auf KWK basierende Fernwaermenetze

    Energy Technology Data Exchange (ETDEWEB)

    Gross, Sebastian; Rhein, Martin; Ruehling, Karin [Technische Universitaet Dresden (Germany). Inst. fuer Energietechnik

    2013-06-15

    The district heating based on combined heat and power is a transitional technology on the way to the supply of Germany with renewable energy. In the next years, this transitional technology can only be maintained and expanded when marketability is given. Therefore an appropriate combination has to be found from investment measures. Together with new aspects in the management strategy, these investment measures should significantly improve the marketability. The investment measures also aims to enable a primary energetic, appropriate combination of natural gas-based combined heat and power, renewable energy sources (solar thermal energy, ambient heat) and heat pump technology.

  8. Strong reduction of the cost price of the district heating, an important action against the economical crisis

    International Nuclear Information System (INIS)

    Kolev, N.; Kolev, D.

    2010-01-01

    The reduction of the cost prices is always an important action against the economical crisis. In this paper the reduction of the cost prices of the district heating based on patented inventions of the authors for significant increasing of the energy efficiency at simultaneous production of electric and heat energy for district heating purpose, using as fuel natural gas, is considered. The economical calculations, based on 50 MW electric and 50 MW heat power, show that at the present prices of the natural gas, electric and heat energy, the net profit of the installation will be about 47 millions of levs per year at pay back term of only about 1,2 years. Even if the price of the heat is reduced twice the profit will be about 35 millions of levs per year at pay back term 1,623 years. (authors)

  9. Influence of biomass cofiring on the optimal coefficient of the cogeneration share in a district heating system

    Directory of Open Access Journals (Sweden)

    Ziębik Andrzej

    2014-03-01

    Full Text Available The paper presents a modified algorithm for choosing the optimal coefficient of the share of cogeneration in district heating systems taking into account additional benefits concerning the promotion of highefficiency cogeneration and biomass cofiring. The optimal coefficient of the share of cogeneration depends first of all on the share of the heat required for preparing the hot tap water. The final result of investigations is an empirical equation describing the influence of the ratio of the heat flux for the production of hot tap water to the maximum flux for space heating and ventilation, as well as the share of chemical energy of biomass in the fuel mixture on the optimal value of the share of cogeneration in district heating systems. The approach presented in the paper may be applied both in back-pressure combined heat and power (CHP plants and in extraction-condensing CHP plants.

  10. Combined use of solar heat and cogeneration - a perspective for district heating?; Kombinierter Einsatz von solarer Waerme und Kraft-Waerme-Kopplung - eine Perspektive fuer die Nahwaerme?

    Energy Technology Data Exchange (ETDEWEB)

    Entress, J. [Deutsches Zentrum fuer Luft- und Raumfahrt (DLR), Stuttgart (Germany). Abt. Systemanalyse und Technikbewertung; Steinborn, F. [Zentrum fuer Sonnenenergie- und Wasserstoff-Forschung Baden-Wuerttemberg (ZSW), Stuttgart (Germany). Fachgebiet Systemanalyse

    1998-02-01

    With Cogeneration of Heat and Power (CHP), climate-endangering CO{sub 2}-emissions can be reduced singificantly. The heat produced can be delivered at prices comparable to those of conventionally produced heat. With solar district heating, yet higher CO{sub 2}-savings are possible but at higher cost. Promising is a combination of CHP and solar district heating: The heat storage of the solar system can be used to level out heat demand, leading to smooth CHP operation, while heat generated by CHP can be used to substitute for low irradiation during the winter period. However, calculations together with simulation and optimization indicate that combining CHP and solar district heating is not the optimal solution in all cases. (orig.) [Deutsch] Der Einsatz von Blockheizkraftwerken (BHKW) kann zu einer deutlichen Reduzierung der klimagefaehrdenden CO{sub 2}-Emissionen beitragen. Dabei kann die ausgekoppelte Waerme etwa zum gleichen Preis wie konventionell erzeugte Waerme abgegeben werden. Hoehere CO{sub 2}-Einsparungen lassen sich hingegen mit solarer Nahwaerme erzielen, allerdings zu hoeheren Kosten. Eine Kombination dieser beiden Waermetechniken verspricht Vorteile: Einerseits kann der Waermespeicher des Solarsystems auch zum Ausgleich von Lastspitzen beim Betrieb des BHKW`s genutzt werden. Andererseits kann die waehrend der einstrahlungsarmen Wintermonate fehlende solare Waerme durch das BHKW erzeugt werden. Detaillierte Simulations- und Optimierungsrechnungen zeigen jedoch, dass eine Kombination dieser Waermetechniken nicht immer empfehlenswert ist. (orig.)

  11. Method for reducing excess heat supply experienced in typical Chinese district heating systems by achieving hydraulic balance and improving indoor air temperature control at the building level

    DEFF Research Database (Denmark)

    Zhang, Lipeng; Gudmundsson, Oddgeir; Thorsen, Jan Eric

    2016-01-01

    A common problem with Chinese district heating systems is that they supply more heat than the actual heat demand. The reason for this excess heat supply is the general failure to use control devices to adjust the indoor temperature and flow in the building heating systems in accordance......, and stabilize indoor temperatures. The feasibility and the energy consumption reduction of this approach were verified by means of simulation and a field test. By moving the system from centrally planned heat delivery to demand-driven heat delivery, excess heat loss can be significantly reduced. Results show...... that once the hydraulic balance is achieved and indoor temperatures are controlled with this integrated approach, 17% heat savings and 42.8% pump electricity savings can be achieved. The energy savings will also have a positive environmental effect with seasonal reductions of 11 kg CO2, 0.1 kg SO2, and 0...

  12. DReAM: Demand Response Architecture for Multi-level District Heating and Cooling Networks

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, Saptarshi; Chandan, Vikas; Arya, Vijay; Kar, Koushik

    2017-05-19

    In this paper, we exploit the inherent hierarchy of heat exchangers in District Heating and Cooling (DHC) networks and propose DReAM, a novel Demand Response (DR) architecture for Multi-level DHC networks. DReAM serves to economize system operation while still respecting comfort requirements of individual consumers. Contrary to many present day DR schemes that work on a consumer level granularity, DReAM works at a level of hierarchy above buildings, i.e. substations that supply heat to a group of buildings. This improves the overall DR scalability and reduce the computational complexity. In the first step of the proposed approach, mathematical models of individual substations and their downstream networks are abstracted into appropriately constructed low-complexity structural forms. In the second step, this abstracted information is employed by the utility to perform DR optimization that determines the optimal heat inflow to individual substations rather than buildings, in order to achieve the targeted objectives across the network. We validate the proposed DReAM framework through experimental results under different scenarios on a test network.

  13. Technical and economical prerequisites of special district-heating nuclear power plant development

    International Nuclear Information System (INIS)

    Baturov, B.B.; Boldyrev, V.M.; Losev, V.L.; Sigal, M.V.

    1983-01-01

    Results are presented of technical and economical analysis of advisability of constructing combined Nuclear Power and Heating Plants (NPHP) assuring the possibility of their location near the areas of heat power consumption in case of observing a given degree of radiation safety for population and personnel. Specific features determining the choice of turbine-driven units for such plants are analyzed. Conditions of competiveness of a specialized NPHP with alternative power units, NPHP based on the WWER-1000 reactor and district heating plants (NDHP), are determined. Analysis of design specifications of NPHP with two VK-500 reactor units and structures of capital investments in such a plant reveal that an increase in the total capital investments in the NPHP would not exceed 2% with account of the difference in costs for grid heaters and a corresponding change in dimensions of operation rooms as well as changes in costs of heat removal system (within one site) at the TK turbine replacement by the T turbine

  14. Predicting the Heat Consumption in District Heating Systems using Meteorological Forecasts

    DEFF Research Database (Denmark)

    Nielsen, Henrik Aalborg, orlov 31.07.2008; Madsen, Henrik

    are suggested in a separate chapter of the report. The methods of prediction applied are based on adaptive estimation, whereby the methods adapt to slow changes in the system. This approach is also used to track the transition from e.g. warm to cold periods. Due to different preferences of the households...... that meteorological forecasts are available on-line. Such a service has recently been introduced by the Danish Meteorological Institute. However, actual meteorological forecasts has not been available for the work described here. Assuming the climate to be known the mean absolute relative prediction error for 72 hour...... predictions is 3.8% for data in November, 1995 (17% when no climate information is used). However, at some occasions large deviations occur and in January 1996 a value of 5.5% is obtained. The relative prediction error tends to increase with decreasing heat consumption. Approaches to implementation...

  15. Preliminary business plan: District Heating Company for the city of Handlova, Slovakia

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-06-01

    The city of Handlova, Slovakia, needs to replace its district heating system, which is old, unreliable, and expensive to maintain. The current plant is owned by a state-run utility, the Slovensky Energeticky Podnik (SEP). The plan is to privatize the heating plant, acquire capital to rehabilitate the central plant (converting it to a cogeneration facility), install a new hot-water distribution system, and implement an extensive energy efficiency effort in the residential buildings on the system. System capacity is 100 MWt, with annual heat sales estimated to be 450,000 gigajoules per year (GJ/yr). The capital necessary for system improvements is estimated to be 465 million Slovakian Krowns (SK) (in 1997 price levels). The total market value of existing fixed assets that will survive the rehabilitation effort as part of the new systems is estimated at 342 million SK. There has been substantial analysis and preparation for this activity, which is documented in demand-side and supply-side technical and economic analyses, an integrated demand/supply report, and this preliminary business plan. The preparation includes investigation of ownership, management, and technology alternatives; estimation of the market value of existing assets and investment requirements; and forecasting of future cash flows. These preliminary projections indicate that the cost of heating from the new system will be reasonable from both a cost per unit of energy basis (SK/GJ) and, form the perspective of an apartment dweller in Handlova, on a total cost per year basis. Delivering heat at the projected cost will, however, require a substantial change in the way that the heating plant is run, with proportionally very large reductions in labor, operations and maintenance, and overhead charges. In addition, there will need to be significant revenues from the sale of electricity to the national grid.

  16. Biomass gasification in district heating systems - The effect of economic energy policies

    International Nuclear Information System (INIS)

    Wetterlund, Elisabeth; Soederstroem, Mats

    2010-01-01

    Biomass gasification is considered a key technology in reaching targets for renewable energy and CO 2 emissions reduction. This study evaluates policy instruments affecting the profitability of biomass gasification applications integrated in a Swedish district heating (DH) system for the medium-term future (around year 2025). Two polygeneration applications based on gasification technology are considered in this paper: (1) a biorefinery plant co-producing synthetic natural gas (SNG) and district heat; (2) a combined heat and power (CHP) plant using integrated gasification combined cycle technology. Using an optimisation model we identify the levels of policy support, here assumed to be in the form of tradable certificates, required to make biofuel production competitive to biomass based electricity generation under various energy market conditions. Similarly, the tradable green electricity certificate levels necessary to make gasification based electricity generation competitive to conventional steam cycle technology, are identified. The results show that in order for investment in the SNG biorefinery to be competitive to investment in electricity production in the DH system, biofuel certificates in the range of 24-42 EUR/MWh are needed. Electricity certificates are not a prerequisite for investment in gasification based CHP to be competitive to investment in conventional steam cycle CHP, given sufficiently high electricity prices. While the required biofuel policy support is relatively insensitive to variations in capital cost, the required electricity certificates show high sensitivity to variations in investment costs. It is concluded that the large capital commitment and strong dependency on policy instruments makes it necessary that DH suppliers believe in the long-sightedness of future support policies, in order for investments in large-scale biomass gasification in DH systems to be realised.

  17. Simulating the Impacts of Climate Extremes Across Sectors: The Case of the 2003 European Heat Wave

    Science.gov (United States)

    Schewe, J.; Zhao, F.; Reyer, C.; Breuer, L.; Coll, M.; Deryng, D.; Eddy, T.; Elliott, J. W.; Francois, L. M.; Friend, A. D.; Gerten, D.; Gosling, S.; Gudmundsson, L.; Huber, V.; Kim, H.; Lotze, H. K.; Orth, R.; Seneviratne, S. I.; Tittensor, D.; Vautard, R.; van Vliet, M. T. H.; Wada, Y.

    2017-12-01

    Increased occurrence of extreme climate or weather events is one of the most damaging consequences of global climate change today and in the future. Estimating the impacts of such extreme events across different human and natural systems is crucial for quantifying overall risks from climate change. Are current models fit for this task? Here we use the 2003 European heat wave and drought (EHW) as a historical analogue for comparable events in the future, and evaluate how accurately its impacts are reproduced by a multi-sectoral "super-ensemble" of state-of-the-art impacts models. Our study combines, for the first time, impacts on agriculture, freshwater resources, terrestrial and marine ecosystems, energy, and human health in a consistent multi-model framework. We identify key impacts of the 2003 EHW reported in the literature and/or recorded in publicly available databases, and examine how closely the models reproduce those impacts, applying the same measure of impact magnitude across different sectors. Preliminary results are mixed: While the EHW's impacts on water resources (streamflow) are reproduced well by most global hydrological models, not all crop and natural vegetation models reproduce the magnitude of impacts on agriculture and ecosystem productivity, respectively, and their performance varies by country or region. A hydropower capacity model matches reported hydropower generation anomalies only in some countries, and estimates of heat-related excess mortality from a set of statistical models are consistent with literature reports only for some of the cities investigated. We present a synthesis of simulated and observed impacts across sectors, and reflect on potential improvements in modeling and analyzing cross-sectoral impacts.

  18. Energy policy strategies of the Baltic Sea Region for the post-Kyoto period - focusing on electricity and district heating generation

    Energy Technology Data Exchange (ETDEWEB)

    2012-05-15

    This study presents a comprehensive analysis of energy policy strategies for the Baltic Sea Region for the post-Kyoto period. To this aim, the study provides scenarios for the region in order to develop a both secure and climate-compatible energy system for the year 2020 and beyond. The long-term development of the energy systems in the Baltic Sea Region is analysed, i.e. in Denmark, Estonia, Finland, Germany, Latvia, Lithuania, Norway, Poland, Sweden, and the north western part of Russia. The study focuses on the electricity and district heating sectors. The Baltic Sea Region is comprised of countries with very different economies and characteristics. Hydropower is an important source of electricity generation in Norway, Sweden, Finland and Latvia. Biomass resources are significant throughout the region, deriving from both agricultural residues and large forested areas. Wind power already contributes considerably to electricity generation in countries such as Denmark and Germany, and is likely to play a much greater role in the region in the years to come, both onshore and offshore. In the longer term (2030 and beyond), solar power and geothermal energy could also provide notable contributions to the overall energy supply. The study shows that it is technically possible to reduce greenhouse gas emissions in the electricity and district heating sectors of the Baltic Sea Region by close to 100% using mainly renewable energy sources. The results indicate that this is a challenging, but manageable task. The associated costs are moderate and can be further decreased through regional cooperation. Once the various production technologies have the possibility to interact with district heating and flexible electricity consumption, and transmission connections are optimally utilised, it becomes realistic to integrate e.g. large volumes of wind power into the energy system as a whole. Furthermore, the hydro power reservoirs, particularly in Norway, play a key role in

  19. Performance investigation of the Turkish geothermal district heating systems (GDHSs). Paper no. IGEC-1-066

    International Nuclear Information System (INIS)

    Ozgener, L.; Hepbasli, A.; Dincer, I.

    2005-01-01

    Various energy and exergy modeling techniques have been used by many investigators for energy-utilization assessments to minimize losses and maximize energy savings and hence financial savings. Furthermore, performance indices are employed to detect and to evaluate quantitatively the causes of the thermodynamic imperfection of the process under consideration such as exergy analysis. The present study evaluates the performances of the two geothermal district heating systems (GDHSs) installed in Turkey. The GDHSs considered are the Balcova GDHS in Izmir and Salihli GDHS in Manisa, while the exergetic improvement potential (ExIP) and specific exergy index (SExI) are used for the modeling of the entire systems and their essential components for performance evaluations and comparisons as well as possible energy and exergy efficiency improvements. The SExI is found to be 0.07 and 0.049 for the Balcova and Salihli GDHSs, respectively, representing that Balcova and Salihli geothermal fields fall into the medium and low quality geothermal resources according to the Lee's classification, respectively. The values for the ExIP are also obtained as follows: For the BGDHS with thirteen plate-type heat exchangers, fourth heat exchanger has the largest ExIP rate as 69.96 kW, followed by the first, second, and third heat exchangers at 20.07, 11.71, and 4.05 kW capacities, respectively, with the remaining ones under 3 kW, which does not present much potential for improvement. For the SGDHS, the ExIP rate is found to be 106.04 kW for the plate-type heat exchanger. On the other hand, in order to improve the system efficiency, water leaks in the distribution network should be prevented. (author)

  20. HEAT PUMP STATION WITH CARBON DIOXIDE AS A WORKING FLUID ENERGY EFFICIENCY GROWTH IN COMBINED DISTRICT HEATING SYSTEM DUE TO ITS CONTROL SYSTEM OPTIMIZATION

    Directory of Open Access Journals (Sweden)

    Sit B.M.

    2008-04-01

    Full Text Available A diagram of the heat pump station (HPS for the central heat supply station of the district heating system, which gets the power from the CHP plant is examined. A block diagram of the control of the system and compressor pressure control system are examined. The description of the control laws of evaporator at the variable heat load of the HPS and control laws of the gas cooler taking into account the goal of achieving the maximum of COP of HPS is shown as well.

  1. RESTful M2M Gateway for Remote Wireless Monitoring for District Central Heating Networks

    Directory of Open Access Journals (Sweden)

    Bo Cheng

    2014-11-01

    Full Text Available In recent years, the increased interest in energy conservation and environmental protection, combined with the development of modern communication and computer technology, has resulted in the replacement of distributed heating by central heating in urban areas. This paper proposes a Representational State Transfer (REST Machine-to-Machine (M2M gateway for wireless remote monitoring for a district central heating network. In particular, we focus on the resource-oriented RESTful M2M gateway architecture, and present an uniform devices abstraction approach based on Open Service Gateway Initiative (OSGi technology, and implement the resource mapping mechanism between resource address mapping mechanism between RESTful resources and the physical sensor devices, and present the buffer queue combined with polling method to implement the data scheduling and Quality of Service (QoS guarantee, and also give the RESTful M2M gateway open service Application Programming Interface (API set. The performance has been measured and analyzed. Finally, the conclusions and future work are presented.

  2. Efficiency grains in Danish District Heating. Is here anything to learn from benchmarking?

    Energy Technology Data Exchange (ETDEWEB)

    Munksgaard, J.; Pade, L.L. [Amternes og Kommunernes Forskningsinstitut, Copenhagen (Denmark); Fristrup, P. [Risoe National Lab., Systemanalyse Dept., Roskilde (Denmark)

    2003-10-01

    Facing a market structure of independent heating systems and cost-of-service regulation the regulator considers ways to create incentives for increasing efficiency in heat production. One way is to implement benchmark regulation. The aim of this paper is twofold: 1) To investigate the potential for increasing productivity in Danish district heating production and 2) to examine whether benchmarking has a role to play. Using DEA (Data Envelopment Analysis) our analyses show that by assuming variable returns to scale there exist a potential to reduce production costs by 5-27 % depending on the portfolie of inputs and outputs included in the model. Further, our analyses show that the ranking of produres are much dependent on the choice of model. The weakness of DEA, however, is that the choice of model can not be founded on solid theoretical ground. Therefore it is hard to decide on the appropriate model to be used. That points to the conclusion that great care has to be taken when implementing benchmarking as a regulatory mean. (au)

  3. RESTful M2M gateway for remote wireless monitoring for district central heating networks.

    Science.gov (United States)

    Cheng, Bo; Wei, Zesan

    2014-11-27

    In recent years, the increased interest in energy conservation and environmental protection, combined with the development of modern communication and computer technology, has resulted in the replacement of distributed heating by central heating in urban areas. This paper proposes a Representational State Transfer (REST) Machine-to-Machine (M2M) gateway for wireless remote monitoring for a district central heating network. In particular, we focus on the resource-oriented RESTful M2M gateway architecture, and present an uniform devices abstraction approach based on Open Service Gateway Initiative (OSGi) technology, and implement the resource mapping mechanism between resource address mapping mechanism between RESTful resources and the physical sensor devices, and present the buffer queue combined with polling method to implement the data scheduling and Quality of Service (QoS) guarantee, and also give the RESTful M2M gateway open service Application Programming Interface (API) set. The performance has been measured and analyzed. Finally, the conclusions and future work are presented.

  4. The assessment of global thermo-energy performances of existing district heating systems optimized by harnessing renewable energy sources

    Science.gov (United States)

    Şoimoşan, Teodora M.; Danku, Gelu; Felseghi, Raluca A.

    2017-12-01

    Within the thermo-energy optimization process of an existing heating system, the increase of the system's energy efficiency and speeding-up the transition to green energy use are pursued. The concept of multi-energy district heating system, with high harnessing levels of the renewable energy sources (RES) in order to produce heat, is expected to be the key-element in the future urban energy infrastructure, due to the important role it can have in the strategies of optimizing and decarbonizing the existing district heating systems. The issues that arise are related to the efficient integration of different technologies of harnessing renewable energy sources in the energy mix and to the increase of the participation levels of RES, respectively. For the holistic modeling of the district heating system, the concept of the energy hub was used, where the synergy of different primary forms of entered energy provides the system a high degree energy security and flexibility in operation. The optimization of energy flows within the energy hub allows the optimization of the thermo-energy district system in order to approach the dual concept of smart city & smart energy.

  5. Thermo-economic optimization of secondary distribution network of low temperature district heating network under local conditions of South Korea

    DEFF Research Database (Denmark)

    Park, Byung Sik; Imran, Muhammad; Hoon, Im-Yong

    2017-01-01

    A secondary distribution network of a low temperature district heating system is designed and optimized for a residential apartment complex under the local conditions of South Korea in the TRNSYS simulation environment. The residential apartment complex is a typical example of Korean residential...... °C, area of heat exchanger is increased by 68.2%, pumping power is also increased by 9.8% and heat loss is reduced by 15.6%. These results correspond to a temperature difference of 20 °C, the standard temperature difference in South Korea residential heating system. Economic assessment...

  6. Corrosion Behavior of Pipeline Carbon Steel under Different Iron Oxide Deposits in the District Heating System

    Directory of Open Access Journals (Sweden)

    Yong-Sang Kim

    2017-05-01

    Full Text Available The corrosion behavior of pipeline steel covered by iron oxides (α-FeOOH; Fe3O4 and Fe2O3 was investigated in simulated district heating water. In potentiodynamic polarization tests; the corrosion rate of pipeline steel is increased under the iron oxide but the increaseing rate is different due to the differnet chemical reactions of the covered iron oxides. Pitting corrosion was only observed on the α-FeOOH-covered specimen; which is caused by the crevice corrosion under the α-FeOOH. From Mott-Schottky and X-ray diffraction results; the surface reaction and oxide layer were dependent on the kind of iron oxides. The iron oxides deposit increases the failure risk of the pipeline and localized corrosion can be occurred under the α-FeOOH-covered region of the pipeline. Thus, prevention methods for the iron oxide deposit in the district pipeline system such as filtering or periodic chemical cleaning are needed.

  7. The energy-effective redesign of district heat supply for the city of Eisenach; Energiewirtschaftliche Neugestaltung der Fernwaermeversorgung fuer die Stadt Eisenach

    Energy Technology Data Exchange (ETDEWEB)

    Stich, J. [Eproplan GmbH, Stuttgart (Germany)

    1996-09-01

    The present contribution describes the optimal heat generation for the district heat area ``North`` of the city of Eisenach and economic redesign of this district heat network. The district heat network is operated by the public utility of Eisenach (Eisenacher Versorgungs-Betriebe GmbH (EVB)), which also runs the heating station, that used to be fuelled with coal. (orig./GL) [Deutsch] Der vorliegende Beitrag befasst sich mit der optimalen Waermeerzeugung fuer das Fernwaerme-Versorgungsgebiet `Nord` der Stadt Eisenach und mit der wirtschaftlichen Umgestaltung dieses Fernwaermenetzes. Das Fernwaermenetz wird durch die Eisenacher Versorgungs-Betriebe GmbH (EVB) betrieben, wie auch das ehemalige kohlegefeuerte Heizwerk. (orig./GL)

  8. Evaluation of approaches for modeling temperature wave propagation in district heating pipelines

    DEFF Research Database (Denmark)

    Gabrielaitiene, I.; Bøhm, Benny; Sunden, B.

    2008-01-01

    The limitations of a pseudo-transient approach for modeling temperature wave propagation in district heating pipes were investigated by comparing numerical predictions with experimental data. The performance of two approaches, namely a pseudo-transient approach implemented in the finite element...... code ANSYS and a node method, was examined for a low turbulent Reynolds number regime and small velocity fluctuations. Both approaches are found to have limitations in predicting the temperature response time and predicting the peak values of the temperature wave, which is further hampered by the fact...... that the fluid is represented as an ideal fluid. The approaches failed to adequately predict the temperature wave propagation in the case of rapid inlet temperature changes. The overall conclusion from this case study was that in order to improve the prediction of the transient temperature, attention has...

  9. Bulgarian district heating system feasibility study. Section 9. Investment program and financial strategy. Export trade information

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-01

    The study, conducted by Gilbert/Commonwealth International, was funded by the U.S. Trade and Development Agency on behalf of the Committee of Energy of the Government of Bulgaria. The report presents the results of a comprehensive study to upgrade the capacity, reliability and efficiency of the District Heating Systems in Sofia and Pernik Cities. The study also covers the condition of the existing facilities and equipment as well as plans for upgrading and the implementation of new equipment for the plants. The report is divided into 11 volumes. Volume 10 contains the Investment Program and Financial Strategy and is divided into the following sections: (1) Introduction; (2) Discussion of Input Data; (3) Description of Model; (4) Analysis and Results; (5) Conclusions and Recommendations.

  10. Reducing time for construction of district heating pipe systems; Foerkorta Byggtider foer Fjaerrvaermebyggnation

    Energy Technology Data Exchange (ETDEWEB)

    Gille, Hans [AaF Energi och Miljoe AB, Stockholm (Sweden)

    2004-07-01

    To enable shorter time of disturbance during construction of pipes for district heating there are several things that can be done. You have foremost to concentrate on the works taking place in and around the trenches for the pipes, from the first grip with the excavator until the refilling is done. There are also possibilities to reduce time for the welding works by looking over methods used for welding and, above all, when you change from welding with gas to welding with electricity. Welding with gas can be applied to larger pipe dimensions than what is common today. It takes half the time to weld with gas compared to weld with electricity, meaning that cost for welding works can be reduced. The right planning, right organisation on the site and right management of the works are the keys to success. Many of the district heating projects taking place are characterized by long open trenches and the installation of the pipes take place in as long stages as possible for pressure testing. If you can find a possible way to use less covering of the pipes and make the trenches as shallow as possible it will give possibilities to reduce time for interruption and also reduce time for construction works. To be able to reduce the length of and also the time for open trenches there is a possibility to use the same method as when you construct pipes for water and sewage systems. Work and organisation of the site must be planned on the basis of this. The question is it reasonable with such long time of disturbance for a few hundreds meter piping? There are several possibilities and measures which together make it possible to reduce time for open trenches considerably.

  11. District space heating potential of low temperature hydrothermal geothermal resources in the southwestern United States. Technical report

    Energy Technology Data Exchange (ETDEWEB)

    McDevitt, P.K.; Rao, C.R.

    1978-10-01

    A computer simulation model (GIRORA-Nonelectric) is developed to study the economics of district space heating using geothermal energy. GIRORA-Nonelectric is a discounted cashflow investment model which evaluates the financial return on investment for space heating. This model consists of two major submodels: the exploration for and development of a geothermal anomaly by a geothermal producer, and the purchase of geothermal fluid by a district heating unit. The primary output of the model is a calculated rate of return on investment earned by the geothermal producer. The results of the sensitivity analysis of the model subject to changes in physical and economic parameters are given in this report. Using the results of the economic analysis and technological screening criteria, all the low temperature geothermal sites in Southwestern United States are examined for economic viability for space heating application. The methodology adopted and the results are given.

  12. Methodological Approach to Determining the Effect of Parallel Energy Consumption on District Heating System

    Science.gov (United States)

    Latosov, Eduard; Volkova, Anna; Siirde, Andres; Kurnitski, Jarek; Thalfeldt, Martin

    2017-05-01

    District heating (DH) offers the most effective way to enhance the efficiency of primary energy use, increasing the share of renewable energy in energy consumption and decreasing the amount of CO2 emissions. According to Article 9 section 1 of the Directive 2010/31/EU of the European Parliament and of the Council of 19 May 2010 on the energy performance of buildings, the Member states of the European Union are obligated to draw up National Plans for increasing the number of nearly zero-energy buildings [1]. Article 2 section 2 of the same Directive states that the energy used in nearly zero-energy buildings should be created covered to a very significant extent by energy from renewable sources, including energy from renewable sources produced on-site or nearby. Thus, the heat distributed by DH systems and produced by manufacturing devices located in close vicinity of the building also have to be taken into account in determining the energy consumption of the building and the share of renewable energy used in the nearly zero-energy buildings. With regard to the spreading of nearly zero-energy and zero-energy houses, the feasibility of on-site energy (heat and/or electricity) production and consumption in DH areas energy (i.e. parallel consumption, when the consumer, connected to DH system, consumes energy for heat production from other sources besides the DH system as well) needs to be examined. In order to do that, it is necessary to implement a versatile methodological approach based on the principles discussed in this article.

  13. Case study on natural gas application for district heating and cooling in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Maues, Jair Arone [Pontificia Universidade Catolica do Rio de Janeiro (IE/PUC-Rio), Rio de Janeiro, RJ (Brazil). Inst. de Energia; Akiyama, Junichi [Mitsui Gas e Energia do Brasil Ltda., Rio de janeiro, RJ (Brazil)

    2012-07-01

    The distributed cogeneration applying natural gas consists in an excellent alternative to use this source, but it is limited by a compatible heat demand that must be found in its application. District heating and cooling solutions can overcome this hurdle, especially in Brazil, a tropical country, where new industrial and commercial enterprises usually install central air conditioning systems. By 2020 natural gas demand shall reach a value of more than 200 MM m{sup 3} per day, accordingly to the Brazilian Energy Research Office (EPE, 2011). An expressive part of it could be consumed in cogeneration systems like the one described in this paper. This project had a special taxes exception rule applied. The chilled water and heated thermal oil produced were not taxed at all. But these two DHC utilities could obtain a different treatment if someone considers this is a tricky way of power and heat trading, which should be taxed as electricity and natural gas normally are. A bolder legislation with respect to the export of energy surplus would facilitate the project and operation of this kind of system, because the basic premise would be to attend the thermal demand with the electrical power installed, maximizing the global efficiency of the installation. An average 8 GW of Brazilian power demand, with roughly 50 MMm{sup 3}/day of natural gas consumption, could be attended by distributed energy gas cogeneration enterprises. If this prediction were totally accomplished it would bring the Brazilian participation of distributed energy in total power generation to values close to 10% in 2020, value already reached in average by the world biggest electricity's consumer countries (WADE, 2006). This also would mean an equivalent investment economy of approximately 11,000 MW in transmission and distribution lines capacity (author)

  14. Costs for Alternatives to District Heating. A study of real costs on local heating markets; Alternativkostnad till fjaerrvaerme. En studie av verkliga kostnader paa lokala vaermemarknader

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, Annelie; Lehtmets, Marti; Andersson, Sofie

    2008-07-01

    Heating comprise the major part of the cost of supporting a building with necessities like electricity, heat, refuse collection and water and sewage. As these costs increase, it is becoming more interesting to find other solutions in order to reduce them. One alternative is to convert to another heating system. Several price analyses comparing different heating systems have been performed. Avgiftsgruppen publishes one report on a yearly basis, where the costs to support a building with necessities and how they vary between communities are listed. The latest report states that it is less expensive in 75 % of the communities in Sweden to convert from district heating to a pellets boiler or a ground-source pump. However, other studies have established that the heat market is a local market with local conditions. Therefore you need to compare alternative heating costs that are specific to the area instead of estimated average costs at a national level. The purpose of this survey is to study a local heat market in order to verify the real cost of the alternative heating systems to district heating and if these costs vary between different communities. The hypothesis is that it is not possible to generalize the heating cost on a national level. Instead, a local market should be studied to make an accurate cost comparison between heating options. Three communities are studied in order to find real and verified investment costs in pellet boilers and heat pumps. The investments that are of primary interest are those performed in buildings similar to the multi-dwelling house used in earlier price analyses. Furthermore, the building should be located within the distribution network of district heating in order to illustrate the competition between the heating alternatives. The result of the study illustrates the difficulties to find real and verified costs of completed investments in alternative heating systems in buildings that is of primary interest for this study. Contacts

  15. Comfortable district heating by ingenious PLC-control. Solar heat for district heating and hot water; Comfortabele stadswarmte dankzij ingenieuze PLC-regeling. Zonnewarmte voor stadverwarming en warm tapwater

    Energy Technology Data Exchange (ETDEWEB)

    Bezemer, R. [Bezemer Communicatie, Brummen (Netherlands)

    2010-07-15

    Over 45,000 dwellings in Almere, the Netherlands, are connected to a district heating grid. The energy supplier uses residual heat that is released by a CHP plant in Almere Stad. As of recently, 'Zoneiland Almere' (1.5 ha in size, 7,000 m{sup 2} of solar collectors) is supplying about 9,750 GJ/a. This covers about 10% of the energy demand of a district with about 2,700 dwellings. PLC is the abbreviation of Product-Logic-Circuit. [Dutch] Meer dan 45.000 woningen in Almere zijn aangesloten op een stadswarmte netwerk. De energieleverancier gebruikt restwarmte die vrijkomt bij een warmtekrachtcentrale in Almere Stad. Sinds kort levert 'Zoneiland Almere' (1,5 ha groot, met daarop 7.000 m{sup 2} zonnecollectoren) circa 9.750 GJ/a. Dit komt overeen met 10 procent van de energiebehoefte van een wijk met 2.700 woningen. PLC staat voor Product-Logic-Circuit.

  16. Master plan study - District heating Kohtla-Jaerve and Johvi municipalities. Estonia. Final report. Appendices for chapter 9

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The appendices to chapter nine of the final report of the master plan study on district heating in the municipalities of Kohtla-Jarve and Johvi municipalities (Estonia) present extensive data relating to economic, financial and environmental calculations, fuel consumption, energy balance and prices. (ARW)

  17. Feasibility Study for the Ivano-Frankivsk District Heating Repowering: Analysis of Options

    Energy Technology Data Exchange (ETDEWEB)

    Markel, L.; Popelka, A.; Laskarevsky, V.

    2002-03-20

    Part of the U.S. Initiative on Joint Implementation with the Ukraine Inter-Ministerial Commission on Climate Change, financed by the US Department of Energy. The project was implemented by a team consisting of the US company SenTech, Inc. and the Ukrainian company Esco-West. The main objective of the effort was to assess available alternatives of Ivano-Frankivsk (I-F) District Heating repowering and provide information for I-F's investment decision process. This study provides information on positive and negative technical and economic aspects of available options. Three options were analyzed for technical merit and economic performance: 1. Installation of cogeneration system based on Gas Turbine (GT) and Heat Recovery Heat Exchanger with thermal capacity of 30 MW and electrical capacity of 13.5 MW. This Option assumes utilization of five existing boilers with total capacity of 221 MW. Existing boilers will be equipped with modern controls. Equipment in this Option was sized for longest operating hours, about 8000 based on the available summer baseload. 2. Installation of Gas Turbine Combined Cycle (GTCC) and Heat Recovery Steam Generator (HRSG) with thermal capacity 45 MW and electrical capacity of 58.7 MW. This Option assumes utilization of five existing boilers with total capacity of 221 MW. Existing boilers will be equipped with modern controls. The equipment was sized for medium, shoulder season thermal load, and some cooling was assumed during the summer operation for extension of operating hours for electricity production. 3. Retrofit of six existing boilers (NGB) with total thermal capacity of 255.9 MW by installation of modern control system and minor upgrades. This option assumes only heat production with minimum investment. The best economic performance and the largest investment cost would result from alternative GTCC. This alternative has positive Net Present Value (NPV) with discount rate lower than about 12%, and has IRR slightly above 12%. The

  18. Awarding legal and Union legal specifications for the routing and operation of district heating pipelines in the public street space; Vergabe- und unionsrechtliche Vorgaben fuer die Verlegung und den Betrieb von Fernwaermeleitungen im oeffentlichen Strassenraum

    Energy Technology Data Exchange (ETDEWEB)

    Reidt, Olaf

    2012-08-15

    The contribution under consideration deals with the question which requirements arise from the national competition and procurement law under EU law for the construction, the continued existence and operation of district heating pipes in public streets. In particular, the question will be whether the planned signing of a concession agreement or the imminent expiry of a fixed-term concession agreement are to be made known throughout the Union. Various constellations in the district heating sector will comment on whether the EU law procurement directives require the compliance with the antitrust laws. Then the requirements of the European primary law are presented for such cases in which the public procurement directives and the cartel procurement law are not relevant.

  19. Do liberalised electricity markets help or hinder CHP and district heating? The case of the UK

    International Nuclear Information System (INIS)

    Toke, David; Fragaki, Aikaterini

    2008-01-01

    This paper investigates whether and how Danish-style combined heat and power (CHP) and district heating (DH) can be implemented in the UK in the context of a liberalised electricity market. There is currently an absence, in the UK, of the Danish system of planning rules and also good tariffs for CHP electricity exports to the grid that led to the development of the Danish system of CHP and DH. However, there are some changes in UK planning practice that may help CHP and DH. These would need to be strengthened, but it is also the case that the way the liberalised electricity market operates in the UK effectively discriminates against small CHP plant selling their electricity to the grid. A Danish system of 'aggregating' CHP-DH plant using thermal stores could help to overcome this problem. However, an alternative strategy would be to establish feed-in tariffs for CHP units that are linked to DH modelled on the Danish 'triple tariff'. This could help the UK's long-term objective of absorbing high levels of fluctuating renewable energy sources

  20. Book of abstracts: International Conference on Smart Energy Systems and 4th Generation District Heating

    DEFF Research Database (Denmark)

    with a particular focus on renewable energy in the transport system in a context with limited access to bioenergy. The Smart Energy System concept is essential for 100% renewable energy systems to harvest storage synergies and exploit low-value heat sources. As opposed to, for instance, the smart grid concept......, which takes a sole focus on the electricity sector, the smart energy systems approach includes the entire energy system in its identification of suitable energy infrastructure designs and operation strategies. Focusing solely on the smart electricity grid often leads to the definition of transmission...... lines, flexible electricity demands, and electricity storage as the primary means to dealing with the integration of fluctuating renewable sources. However, these measures are neither very effective nor cost-efficient considering the nature of wind power and similar sources. The most effective and least...

  1. District heating and cogeneration in the EU-28: Current situation, potential and proposed energy strategy for its generalisation

    Directory of Open Access Journals (Sweden)

    Enrique Rosales-Asensio

    2016-10-01

    Full Text Available Yearly, EU-28 conventional thermal generating plants reject a greater amount of energy than what ultimately is utilised by residential and commercial loads for heating and hot water. If this waste heat were to be used through district heating networks, given a previous energy valorisation, there would be a noticeable decrease in imported fossil fuels for heating. As a consequence, benefits in the form of an energy efficiency increase, an energy security improvement, and a minimisation of emitted greenhouse gases would occur. Given that it is not expected for heat demand to decrease significantly in the medium term, district heating networks show the greatest potential for the development of cogeneration. However, to make this happen, some barriers that are far from being technological but are mostly institutional and financial need to be removed. The purpose of this review is to provide information on the potential of using waste heat from conventional thermal power plants (subsequently converted into cogeneration plants in district heating networks located in the EU-28. For this, a preliminary assessment is conducted in order to show an estimate of the cost of adopting an energy strategy in which district heating networks are a major player of the energy mix. From this assessment, it is possible to see that even though the energy strategy proposed in this paper, which is based on a dramatic increase in the joint use of district heating networks and cogeneration, is capital-intensive and would require an annual investment of roughly 300 billion euros, its adoption would result in a reduction of yearly fuel expenses in the order of 100 billion euros and a shortening of about 15% of the total final energy consumption, which makes it of paramount interest as an enabler of the legal basis of the “Secure, Clean and Efficient Energy” future enacted by the EU-28 Horizon 2020.

  2. Energy, economy and exergy evaluations of the solutions for supplying domestic hot water from low-temperature district heating in Denmark

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Li, Hongwei; Svendsen, Svend

    2016-01-01

    . Evaluation models were built to investigate the energy, economy and exergy performances of the proposed domestic hot water systems in various configurations. The configurations of the devised domestic hot water substations were optimised to fit well with both low and ultra-low-temperature district heating...... and to reduce the return temperature to district heating. The benefits of lower return temperatures were also analysed compared with the current district heating situation. The evaluation results show that the decentralized substation system with instantaneous heat exchanger unit performed better under the 65...

  3. Determining the Optimal Capacities of Renewable-Energy-Based Energy Conversion Systems for Meeting the Demands of Low-Energy District Heating, Electricity, and District Cooling

    DEFF Research Database (Denmark)

    Tol, Hakan; Svendsen, Svend; Dincer, Ibrahim

    2015-01-01

    as 55 °C for supply and 25 °C for return, and with additional considerations being directed to supply electricity and cooling. Several optimal solutions with various nominal capacities of the technologies involved were obtained in each of the two case studies, one being for the Greater Copenhagen Area......, and the other for the Greater Toronto Area. Various climate conditions of the case areas in question caused different observations of nominal capacities for the energy conversion systems considered with single-production and multi-production based on different renewable energy sources.......This chapter presents a method for determining the optimal capacity of a renewable-energy-based energy conversion system for meeting the energy requirements of a given district as considered on a monthly basis, with use of a low-energy district heating system operating at a low temperature, as low...

  4. Process heat in California: Applications and potential for solar energy in the industrial, agricultural and commercial sectors

    Science.gov (United States)

    Barbieri, R. H.; Bartera, R. E.; Davis, E. S.; Hlavka, G. E.; Pivirotto, D. S.; Yanow, G.

    1978-01-01

    A summary of the results of a survey of potential applications of solar energy for supplying process heat requirements in the industrial, agricultural, and commercial sectors of California is presented. Technical, economic, and institutional characteristics of the three sectors are examined. Specific applications for solar energy are then discussed. Finally, implications for California energy policy are discussed along with recommendations for possible actions by the State of California.

  5. Feasibility analysis of fuel cells for combined heat and power systems in the tertiary sector

    Energy Technology Data Exchange (ETDEWEB)

    Zabalza, Ignacio; Aranda, Alfonso [CIRCE - Centre of Research for Energy Resources and Consumption, Polytechnic Centre, University of Zaragoza, Maria de Luna, 3, 50018 Zaragoza (Spain); Dolores de Gracia, Maria [Institute for Energy Engineering, Advanced Systems Group, Polytechnic University of Valencia, Camino de Vera s/n, 46022 Valencia (Spain)

    2007-07-15

    The aim of this paper is to present a feasibility analysis of the application of fuel cells for a combined heat and power system with grid connection in the tertiary sector. Although the analysis considers Spanish data, the methodology proposed is developed to be applicable at the EU level. The current legislative framework is analysed in order to establish the suitability of the payment scheme considered for the sale of surplus electricity from these systems. The paper also establishes criteria for the optimal design of distributed generation systems based on fuel cells from a technical, economic and environmental point of view, presenting the strategies that should be implemented to promote the future implantation of these systems and their progressive introduction to the market. (author)

  6. Particulate emissions from biomass combustion in small district heating plants; Partikelemissioner fraan biobraensleeldade mindre fjaerrvaermecentraler

    Energy Technology Data Exchange (ETDEWEB)

    Persson, Henrik; Johansson, Linda; Tullin, Claes; Oesterberg, Stefan; Johansson, Mathias [Swedish National Testing and Research Inst., Boraas (Sweden); Leckner, Bo [Chalmers Univ. of Technology, Goeteborg (Sweden). Energy Conversion

    2001-12-01

    In recent years, negative health effects associated with increased levels of PM{sub 10} and PM{sub 2.5} (particles less then 10 and 2.5 {mu}m, respectively) in the ambient air have been highlighted. The development towards a sustainable society will lead to an increased use of biomass in Sweden. Conversion from oil to biomass can lead to increased local levels of particulate matter. In smaller district heating plants (up to a few MW), the dust reduction often is restricted to the use of cyclones/multicyclones having limited separation efficiency for submicron particles (particles less than 1 {mu}m). The emissions are often in the range 100 Mg/nm{sup 3} or higher but very few data regarding particle size distributions from district heating plants have been reported in the literature. In addition to the particle size, a number of other properties might be important for the health effects but the knowledge in this area is limited. It is therefore important to characterise the particles in detail regarding physical and chemical qualities. The objective with the present investigation is to measure and characterise the particulate emissions from two biomass based smaller district heating centrals for different fuel qualities (pellets, briquettes, forest residues and wood chips) and operating parameters such as load and excess air. In addition to analyses of dust and particulates, extensive measurements of the flue composition have been performed. Measurements were performed downstream the multicyclones. The dust emissions were found to be in the range 20 to 120 mg/MJ supplied fuel depending on operating condition and fuel quality. At normal operation, the dust emissions were about 35 to 40 mg/MJ supplied fuel. The particle size distributions were measured using an ELPI (Electric Low Pressure Impactor). The number size distributions were found to be dominated by submicron particles with maxima at diameters between 0. 1 and 0.3 gm. Additional measurements indicated that

  7. A geochemical approach for assessing the possible uses of the geothermal resource in the eastern sector of the Sabatini Volcanic District (Central Italy)

    Science.gov (United States)

    Cinti, Daniele; Tassi, Franco; Procesi, Monia; Brusca, Lorenzo; Cabassi, Jacopo; Capecchiacci, Francesco; Delgado Huertas, Antonio; Galli, Gianfranco; Grassa, Fausto; Vaselli, Orlando; Voltattorni, Nunzia

    2017-04-01

    The Sabatini Volcanic District (SVD) hosts a hydrothermal reservoir heated by the post-magmatic activity that affected the peri-Tyrrhenian sector of central Italy, giving rise to a number of thermal and mineral discharges. In this study, a complete geochemical and isotopic dataset based on the composition of 215 water and 9 bubbling gases, collected from the eastern sector of this huge hydrothermal system, is reported. The main aims are to (i) investigate the fluid sources and the main chemical-physical processes controlling the fluid chemistry and (ii) construct a conceptual fluid circulation model to provide insights into the possible use(s) of the geothermal resource. The fluid discharges are fed by two main aquifers, characterized by: (1) a Ca-HCO3 to Ca(Na)-HCO3 composition, typical of a shallow hydrological circuit within volcanic and sedimentary formations, and (2) a Ca-HCO3(SO4) to Na(Ca)-HCO3(Cl) composition, produced by the interaction of CO2-rich fluids with Mesozoic and Triassic carbonate-evaporite rocks. A thick sequence of low-permeability volcanic products represents a physical barrier between the two fluid reservoirs. As commonly occurring in central-southern Italy, CO2 is mainly produced by thermo-metamorphic decarbonation within the carbonate-evaporite reservoir, with minor contribution of mantle CO2. A dominant crustal source is also indicated by the relatively low R/Ra values (0.07-1.04). Methane and light hydrocarbons are mostly thermogenic, whereas H2S derives from thermogenic reduction of the Triassic anhydrites. Slightly positive 15N/14N values suggest minor N2 contribution from deep sedimentary sources. On the whole, a comparison of these geochemical features with those of the thermal fluids from the western portion of SVD highlights an eastward increasing influence of the shallow aquifer on the deep-originated fluids, likely caused by the proximity of the Apennine range from where the meteoric water, recharging the hydrothermal system

  8. Modelling a district heating system: Introduction of waste incineration, policy instruments and co-operation with an industry

    International Nuclear Information System (INIS)

    The capacity for waste incineration in Swedish municipalities is increasing due to regulations aimed at decreasing landfill with waste. This has a large impact on the municipal energy systems, since waste is an important fuel for district heating production. The object of this study is a municipality, Skoevde, which is planning to build a waste incineration plant to produce electricity and heat. The municipality is also planning to extend the district heating grid to include a large industrial heat consumer. The economic effect on the energy system of these measures is analysed as well as environmental effects in terms of carbon dioxide emissions. The consequences of two different policy instruments, green electricity certificates and a tax on waste incineration, are also studied. Economic optimisations show that the advantage of co-operation with industry is twofold: lower heat production costs and a considerable reduction of carbon dioxide emissions. It is economically feasible to invest in a waste incineration plant for heat production. An important measure to lower carbon dioxide emissions is to introduce combined heat and power production on the assumption that locally produced electricity replaces electricity produced by coal condensing power

  9. Heat Roadmap Europe

    DEFF Research Database (Denmark)

    Connolly, David; Lund, Henrik; Mathiesen, Brian Vad

    2014-01-01

    indicate that with district heating, the EU energy system will be able to achieve the same reductions in primary energy supply and carbon dioxide emissions as the existing alternatives proposed. However, with district heating these goals can be achieved at a lower cost, with heating and cooling costs......Six different strategies have recently been proposed for the European Union (EU) energy system in the European Commission's report, Energy Roadmap 2050. The objective for these strategies is to identify how the EU can reach its target of an 80% reduction in annual greenhouse gas emissions in 2050...... compared to 1990 levels. None of these scenarios involve the large-scale implementation of district heating, but instead they focus on the electrification of the heating sector (primarily using heat pumps) and/or the large-scale implementation of electricity and heat savings. In this paper, the potential...

  10. Modelling and multi-scenario analysis for electric heat tracing system combined with low temperature district heating for domestic hot water supply

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Li, Hongwei; Svendsen, Svend

    2016-01-01

    of the electric heating tracing system with LTDH was simulated by taking the user pattern into account. A smart control method based on thermostatic and real-time control was developed, and compared with normal control method. The impact of user pattern was tested by applying standard, stochastic, and real load......Low temperature district heating (LTDH) is a cost-efficient way of supplying space heating and domestic hot water (DHW) for buildings in urban areas. However, there is concern that the potential hygiene problems (Legionella) might occur if LTDH is implemented, especially for large buildings....... In this study, electric heat tracing system was investigated as a solution to this dilemma. A model of electric heat tracing system for multi-storey buildings was built. Various pipe materials and insulation thicknesses as the parameters of the model were compared to make a comprehensive study. The performance...

  11. Development of a risk analysis model. Appendix F. District heating and cooling system case study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-10-01

    The risk analysis reported in this appendix was concerned with a business venture in the area of district energy systems using thermal energy cogenerated at existing electric power plants. After an introductory section, Section 2, Institutional Issues, discusses investment decisions and regulatory constraints and issues; Section 3 reviews public utility company objectives and investment analysis approach; Section 4 reviews the case study of district heating and cooling systems (DHCS) in Washington, DC; Section 5 results of the Minneapolis/St. Paul case DHCS study; Section 6 summarizes the desired risk-analysis methodology for evaluating regulated utility investment decisions; and Section 7 presents overall conclusions. (MCW)

  12. Assessing District-Heating Sustainability. Case Studies of CO{sub 2} Mitigation Strategies and Environmental Cost Accounting

    Energy Technology Data Exchange (ETDEWEB)

    Fahlen, Elsa

    2012-11-01

    District heating (DH) may play an important role in achieving the EU goal of a secure, competitive and sustainable energy supply. Integrated energy solutions based on technologies, such as biomass gasification for transport fuel, electricity and heat production and heat-driven absorption cooling, create new optimisation possibilities through the linkage between heat, power, cooling and transport fuel markets which may reduce the global warming contribution of the energy sector. With increasing focus on climate change impacts of greenhouse gas emissions, the environmental effects of other air pollutants should not be neglected. To achieve both a competitive and a sustainable energy supply, it is necessary to integrate environmental considerations into economic policies. Through accounting for external costs of air pollution in energy system modelling and analysis, sustainability aspects may be integrated into DH assessments. The aim of this thesis is to develop, apply and evaluate methodologies for assessing conventional and new technology solutions in a DH system; the assessments are made from a DH perspective with respect to two factors - cost-effectiveness and environmental impacts - which are either assessed separately or integrated through external cost accounting. Various CO{sub 2} mitigation strategies are evaluated with regard to the robustness of the DH system in meeting future developments of energy market prices and policies. The studies are performed using a systems approach by using the simulating DH supply model MARTES as applied to the DH system Sweden. This thesis concludes that the integration of biomass gasification technology and absorption cooling technology in DH systems has the potential for cost-effective CO{sub 2} emission reduction, in line with other EU goals to increase the share of renewable sources in energy use and to increase energy efficiency. Accounting for external costs of not only climate change but also other environmental

  13. Iterative Feedback Tuning in district heating systems; Iterative Feedback Tuning i vaermeproduktionsanlaeggningar

    Energy Technology Data Exchange (ETDEWEB)

    Raaberg, Martin; Velut, Stephane; Bari, Siavosh Amanat

    2010-10-15

    The project goal is to evaluate and describe how Iterative Feedback Tuning (IFT) can be used to tune controllers in the typical control loops in heat- and power plants. There are only a few practical studies carried out for IFT and they are not really relevant for power and heat processes. It is the practical problems in implementing the IFT and the result of trimming that is the focus of this project. The project will start with theoretical studies of the IFT-method, then realization and simple simulations in scilab. The IFT equations are then implemented in Freelance 2000, an ABB control system, for practical tests on a SISO- and a MIMO-process. By performing reproducible experiments on the process and analyze the results IFT can adjust the controller parameters to minimize a cost function that represents the control goal. The project selected for SISO experiments a pressure controller in an oil transportation system. By controlling the valve position of a control valve for the reversal to the supply tank, the pressure in the oil transport system is regulated. A disturbance in oil pressure can be achieved by changing the position of a valve that lets oil through to the day tank. The selected MIMO-process is a pre-heater in a degassing process. In this process, a valve on the secondary side is utilized to control the flow in the secondary system. A valve on the primary side is utilized to control the district heating water flow through the heat exchanger to control the temperature on the secondary side. An increased secondary flow increases the heat demand and thus requiring an increase in primary flow to maintain the secondary side outlet temperature. This is the cross-coupling responsible for why it is an advantage to consider the process as multi-variable. Using the IFT method, the two original PID-controllers and a feed-forward controller is tuned simultaneously. IFT-method was difficult to implement but worked well in both simulations and in real processes

  14. EFFECTS OF IMPLEMENTATION OF CO-GENERATION IN THE DISTRICT HEATING SYSTEM OF THE FACULTY OF MECHANICAL ENGINEERING IN NIŠ

    Directory of Open Access Journals (Sweden)

    Mladen M Stojiljković

    2010-01-01

    Full Text Available Implementation of co-generation of thermal and electrical energy in district heating systems often results with higher overall energy efficiency of the systems, primary energy savings and environmental benefits. Financial results depend on number of parameters, some of which are very difficult to predict. After introduction of feed-in tariffs for generation of electrical energy in Serbia, better conditions for implementation of co-generation are created, although in district heating systems barriers are still present. In this paper, possibilities and effects of implementation of natural gas fired co-generation engines are examined and presented for the boiler house that is a part of the district heating system owned and operated by the Faculty of Mechanical Engineering in Niš. At the moment, in this boiler house only thermal energy is produced. The boilers are natural gas fired and often operate in low part load regimes. The plant is working only during the heating season. For estimation of effects of implementation of co-generation, referent values are taken from literature or are based on the results of measurements performed on site. Results are presented in the form of primary energy savings and greenhouse gasses emission reduction potentials. Financial aspects are also considered and triangle of costs is shown.

  15. Integrated production and distribution analysis in District Heating-systems; Samverkande produktions och distributionsanalys i fjaerrvaermesystem

    Energy Technology Data Exchange (ETDEWEB)

    Rossing, Ola [HydroRam, Goeteborg (Sweden); Johnsson, John [Profu, Goeteborg (Sweden)

    2005-01-01

    During the last 10-15 years detailed models for analysing district heating production and distribution has been developed. However, detailed analysis of district heating is in many cases a combined production and distribution issue. The high complexity in both areas has lead to a situation with separate tools for analysis. The consequence of this is that the calculations have, in some cases, been incomplete or even incorrect. Examples of miscalculations are that production calculations in complex systems in many cases give unrealistic production schedules due to the distribution restrictions. On the other hand most distribution calculations do not give economical results. Through integration of production and distribution analyses the analyst is given possibility to verify the production calculation from a distributions perspective and to reach a more realistic result. In order to evaluate the advantage of, and possibilities for, co-operation between the two areas, we have analysed the district heating system of Goeteborg, which is a district heating system of high complexity. The calculations have been made with a production model (Martes) and a distribution model (PFC-SF). The possibility to establish integrated analysis has been evaluated through analysing different technical measures for minimizing the influence of a distribution restriction between the western and eastern part of Goeteborg. The project shows that integrated analysis could be done with a high degree of accuracy and in an effective way. In the project six different measures for minimizing the influences of the distribution restriction was identified. These measures were ranked on an economic basis through the integrated analyses. The change of cost was varied between a cost decrease of seven million SEK/year (increases differential pressure) to a cost increases of 32 million SEK/year (increased supply temperature). The cost reduction of the other measures varied between four and seven million

  16. Solar-assisted district heating systems: The Solarthermie 2000-programme; Solarunterstuetzte Nahwaermeversorgung: Programm Solarthermie-2000

    Energy Technology Data Exchange (ETDEWEB)

    Lottner, V. [Forschungszentrum Juelich GmbH (Germany). Projekttraeger Biologie, Energie, Umwelt (BEO)

    1998-12-31

    In Germany, utilisation of solar energy for thermal energy supply has a considerable technical and economic potential in terms of substitution of fossil fuels and reduction of CO{sub 2} emission. If appropriate technologies are used, solar-assisted district heat supply systems can be a cost-efficient concept for thermal utilisation of solar energy. The BMBF -programme `Solarthermie 2000` supports a number of pilot and demonstration plants in order to test and develop the most promising systems and storage facilities under real conditions. Long-term measuring programmes generate reliable data on thermal performance and cost of the plant concepts and create a solid basis for a technical and economic evaluation. (orig.) [Deutsch] Die Nutzung von Solarenergie fuer die Waermeversorgung bietet in Deutschland ein grosses technisches und wirtschaftliches Potential zur Substitution fossiler Energietraeger und Reduzierung der CO{sub 2} Emissionen in die Atmosphaere. Solarunterstuetzte Nahwaermesysteme stellen unter guenstigen technischen Bedingungen ein kostenguenstiges Konzept der thermischen Nutzung der Solarenergie dar. In dem BMBF-Programm Solarthermie-2000 werden Pilot- und Demonstrationsanlagen gefoerdert, so dass die aussichtsreichsten System- und Speicherkonzepte in der Praxis erprobt und gezielt weiterentwickelt werden koennen. Mit Langzeit-Messprogrammen werden belastbare Werte der thermischen Leistung und Kosten der Anlagenkonzepte ermittelt und eine zuverlaessige Grundlage fuer die technisch-wirtschaftliche Bewertung geschaffen. (orig.)

  17. Use of reactor plants of enhanced safety for sea water desalination, industrial and district heating

    International Nuclear Information System (INIS)

    Panov, Yu.; Polunichev, V.; Zverev, K.

    1997-01-01

    Russian designers have developed and can deliver nuclear complexes to provide sea water desalination, industrial and district heating. This paper provides an overview of these designs utilizing the ABV, KLT-40 and ATETS-80 reactor plants of enhanced safety. The most advanced nuclear powered water desalination project is the APVS-80. This design consists of a special ship equipped with the distillation desalination plant powered at a level of 160 MW(th) utilizing the type KLT-40 reactor plant. More than 20 years of experience with water desalination and reactor plants has been achieved in Aktau and Russian nuclear ships without radioactive contamination of desalinated water. Design is also proceeding on a two structure complex consisting of a floating nuclear power station and a reverse osmosis desalination plant. This new technology for sea water desalination provides the opportunity to considerably reduce the specific consumption of power for the desalination of sea water. The ABV reactor is utilized in the ''Volnolom'' type floating nuclear power stations. This design also features a desalinator ship which provides sea water desalination by the reverse osmosis process. The ATETS-80 is a nuclear two-reactor cogeneration complex which incorporates the integral vessel-type PWR which can be used in the production of electricity, steam, hot and desalinated water. (author). 9 figs

  18. Potentials of district heating grids for climate protection up to the year 2020; Potenziale von Nah- und Fernwaermenetzen fuer den Klimaschutz bis zum Jahr 2020

    Energy Technology Data Exchange (ETDEWEB)

    Fischedick, Manfred; Schuewer, Dietmar; Venjakob, Johannes; Merten, Frank; Mitze, Dirk [Wuppertal Inst. fuer Klima, Umwelt, Energie GmbH (Germany); Nast, Michael; Schillings, Christoph; Krewitt, Wolfram [Deutsches Zentrum fuer Luft- und Raumfahrt (Germany). Inst. fuer Technische Thermodynamik; Bohnenschaefer, Werner; Lindner, Klaus [Institut fuer Energetik und Umwelt, Leipzig (Germany)

    2007-12-15

    District heat is one of Germany's traditional end use energy sources, with a connected capacity of about 57,000 MWth. The heat is distributed via 1,400 grids with a total length of about 19,000 km. The number of households supplied with district heat increased from 9.7 percent in 1993 to 13.7 percent in 2003. About 550 out of about 1,000 German utilities provide district heat to households. During the past few years, the connected capacity of district heating has been stagnating. This is the result of thermal insulation measures, dismantling and abandonment of supply grids, but also of changes on the demand side that can still be compensated by concentration and expansion potentials.

  19. Optimum radiator control to reach a low district heating return temperature; Optimal radiatorreglering foer att naa laag fjaerrvaermereturtemperatur

    Energy Technology Data Exchange (ETDEWEB)

    Ljunggren, Patrick; Wollerstrand, Janusz [Lund Univ. (Sweden). Energy Sciences

    2005-12-15

    The advantages of an improved cooling of primary water in district heating systems are well-known. E.g. heat losses and pumping work can be reduced and the capacity in the network increased. Many kinds of heat production, such as combined heat and power, heat pumps, waste heat and flue gas condensation, are favoured. The choice of connection scheme of district heating substations is nowadays considered to be of less significance for the cooling since the district heating cost only marginally is affected. Of at least the same interest for the cooling, and the cost when flow accounting is applied, is the temperature in the secondary systems connected to the substation. For every combination of space heating system and substation, at given load and supply temperature, there is an optimum magnitude of the flow in the space heating circuit that produces an optimum primary return temperature. It can be shown that, if highest possible cooling of primary water is aimed at, the magnitude of the flow in the circuit should be reduced at part load while the supply temperature should be reduced less than is done with constant flow. One can then speak of a moving transition, with decreasing load, from a high flow balanced system to a low flow balanced system. Oversizing of space heating systems and its components is a rule rather than an exception and implies the possibility to substantially improve the cooling. The calculations and simulations performed show that it is possible, with measurements of temperatures and energy consumption in a space heating system, to estimate the existing oversizing and with that information to establish a temperature program that best fits the system's characteristics. Complete optimization is possible with measurement of the indoor temperature. Online optimization is obstructed by hysteresis in thermostatic valves if the radiators are equipped with these. Both low flow balancing and low temperature adjustment of the oversized space heating

  20. Study of the implantation potential for methanizers at the scale of the Pays-de-Bocage (61). Diagnosis of the situation of the methanization sector and of its development potential - Detailed analysis of scenarios. Study report, November 2016. Action study for the development of territorial methanization - Orne Pays-de-Bocage. Projected methanization units in the Orne district. An opportunity for local companies

    International Nuclear Information System (INIS)

    Carbonnel, Claire; Priarollo, Jeremie; Deborde, Isabelle; Quere, Jean-Jacques; Goasdoue, Yves; Nury, Jerome; Borney, Eric; Bisson, Stephane; Lhomer, Regis

    2016-11-01

    This study aims at characterising territories of the Orne district in terms of potential of development of individual, collective and territorial methanization units. A first phase aimed at providing a situational analysis of the methanization sector in the district. During a second phase, different resources of mobilisable organic wastes have been quantified, characterised and mapped at the district level in combination with energy outlets (gas and heat) and digestate outlets. A third phase aimed identifying and characterising district areas displaying a methanization potential. The report thus presents the territory, the methanization as an opportunity for territories, and an assessment of the present situation of the methanization sector. It gives an assessment of the methanizable matter resource from various origins, an identification of the different energetic outlets, and of potential areas. Four scenarios are then presented and are characterised by specific hypotheses, energy flows, investments, exploitation assessment, and a financial analysis. Agronomic, environmental and regulatory challenges are commented, as well as legal aspects related to project implementation. Power Point presentations are then provided which present results of this study in a synthetic and illustrated way. A second set of Power Point presentations proposes an analysis of the methanization potential in the district, and a description of a typical business model for a methanization unit

  1. Increased combustion stability in modulating biomass boilers for district heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, Gunnar; Hermansson, Roger (eds.) [Lulea Univ. of Technology (Sweden)

    2002-09-01

    One of the problems in small district heating systems is the large load variation that must be handled by the system. If the boiler is designed to cover the needs during the coldest day in winter time in northern Europe it would have to run at loads as low as 10% of full load during summer time, when heat is needed only for tap water production. Load variations in small networks are quite fast and earlier investigations have shown that existing biomass boilers give rise to large amounts of harmful emissions at fast load variations and at low loads. The problem has been addressed in different ways: Three new boiler concepts have been realized and tested: A prototype of a 500 kW boiler with partitioned primary combustion chamber and supplied with a water heat store. A 10 kW bench scale combustor and a 500 kW prototype boiler based on pulsating combustion. Bench scale boilers to test the influence from applied sound on emissions and a 150 kW prototype boiler with a two-stage secondary vortex combustion chamber. Development of control and regulating equipment: Glow Guard, a control system using infra-red sensors to detect glowing char on the grate, has been constructed and tested. A fast prediction model that can be used in control systems has been developed. Simulation of the combustion process: Code to simulate pyrolysis/gasification of fuel on the grate has been developed. Combustion of the gas phase inside the combustion chamber has been simulated. The two models have been combined to describe the combustion process inside the primary chamber of a prototype boiler. A fast simulation code based on statistical methods that can predict the environmental performance of boilers has been developed. One of the boiler concepts matches the desired load span from 10 to 100% of full load with emissions far below the set limits for CO and THC and close to the set limits for NO{sub x}. The other boilers had a bit more narrow load range, one with very low emissions except for NO

  2. Numerical study of the role of microphysical latent heating and surface heat fluxes in a severe precipitation event in the warm sector over southern China

    Science.gov (United States)

    Yin, Jin-Fang; Wang, Dong-Hai; Liang, Zhao-Ming; Liu, Chong-Jian; Zhai, Guo-Qing; Wang, Hong

    2017-12-01

    Simulations of the severe precipitation event that occurred in the warm sector over southern China on 08 May 2014 are conducted using the Advanced Weather Research and Forecasting (WRF-ARWv3.5.1) model to investigate the roles of microphysical latent heating and surface heat fluxes during the severe precipitation processes. At first, observations from surface rain gauges and ground-based weather radars are used to evaluate the model outputs. Results show that the spatial distribution of 24-h accumulated precipitation is well reproduced, and the temporal and spatial distributions of the simulated radar reflectivity agree well with the observations. Then, several sensitive simulations are performed with the identical model configurations, except for different options in microphysical latent heating and surface heat fluxes. From the results, one of the significant findings is that the latent heating from warm rain microphysical processes heats the atmosphere in the initial phase of the precipitation and thus convective systems start by self-triggering and self-organizing, despite the fact that the environmental conditions are not favorable to the occurrence of precipitation event at the initial phase. In the case of the severe precipitation event over the warm sector, both warm and ice microphysical processes are active with the ice microphysics processes activated almost two hours later. According to the sensitive results, there is a very weak precipitation without heavy rainfall belt when microphysical latent heating is turned off. In terms of this precipitation event, the warm microphysics processes play significant roles on precipitation intensity, while the ice microphysics processes have effects on the spatial distribution of precipitation. Both surface sensible and latent heating have effects on the precipitation intensity and spatial distribution. By comparison, the surface sensible heating has a strong influence on the spatial distribution of precipitation

  3. Numerical Study of the Role of Microphysical Latent Heating and Surface Heat Fluxes in a Severe Precipitation Event in the Warm Sector over Southern China

    Science.gov (United States)

    Yin, Jin-Fang; Wang, Dong-Hai; Liang, Zhao-Ming; Liu, Chong-Jian; Zhai, Guo-Qing; Wang, Hong

    2018-02-01

    Simulations of the severe precipitation event that occurred in the warm sector over southern China on 08 May 2014 are conducted using the Advanced Weather Research and Forecasting (WRF-ARWv3.5.1) model to investigate the roles of microphysical latent heating and surface heat fluxes during the severe precipitation processes. At first, observations from surface rain gauges and ground-based weather radars are used to evaluate the model outputs. Results show that the spatial distribution of 24-h accumulated precipitation is well reproduced, and the temporal and spatial distributions of the simulated radar reflectivity agree well with the observations. Then, several sensitive simulations are performed with the identical model configurations, except for different options in microphysical latent heating and surface heat fluxes. From the results, one of the significant findings is that the latent heating from warm rain microphysical processes heats the atmosphere in the initial phase of the precipitation and thus convective systems start by self-triggering and self-organizing, despite the fact that the environmental conditions are not favorable to the occurrence of precipitation event at the initial phase. In the case of the severe precipitation event over the warm sector, both warm and ice microphysical processes are active with the ice microphysics processes activated almost two hours later. According to the sensitive results, there is a very weak precipitation without heavy rainfall belt when microphysical latent heating is turned off. In terms of this precipitation event, the warm microphysics processes play significant roles on precipitation intensity, while the ice microphysics processes have effects on the spatial distribution of precipitation. Both surface sensible and latent heating have effects on the precipitation intensity and spatial distribution. By comparison, the surface sensible heating has a strong influence on the spatial distribution of precipitation

  4. Experience gained in the process of the variable mass heat flow control implemented in the district heat supply system of the city of Gyor

    Energy Technology Data Exchange (ETDEWEB)

    Nagy, F.; Milanovich, L.; Lelek, J.; Kekk, I. [District Heating LTD. of Gyor (Hungary)

    1996-11-01

    The district heating system of the city of Gyor is fed from a hot water boiler plant. The total heat demand for 23,000 residential homes and several public facilities is 260 MW. The variable mass flow control was implemented in 1991 through 1992. Design, preparatory job and the majority of implementation was carried out without external involvement. The paper presents historical background and brief project presentation which is followed by comparative presentation of the variable mass flow control and constant mass flow control. This comparative survey has been conducted on the basis of operating data for 1993 and those for 1988. In the conclusion the gained experience is summarized.

  5. Change in heat load profile for typical Danish multi-storey buildings when energy-renovated and supplied with low-temperature district heating

    DEFF Research Database (Denmark)

    Harrestrup, Maria; Svendsen, Svend

    2013-01-01

    Denmark has a long-term objective of being free of fossil fuels by 2050 with the energysupply-mix for buildings being free of fossil fuels by 2035. Hence energy consumption from existing buildings needs to be decreased concurrent with the conversion from fossil-fuel supply into renewable-energy (RE......) supply. When end-use-savings are implemented in buildings concurrent with the application of low-temperature district heating (DH) (supply=55°C, return=25°C) the heat demand profiles for the individual buildings will change. The reduction in peak load is important since it is the dimensioning foundation...

  6. District heating and cooling systems for communities through power plant retrofit and distribution network. Final report. Volume I. Text

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-09-15

    An analysis was performed investigating the potential of retrofitting Detroit Edison's Conners Creek power plant to supply district heating and cooling to an area surrounding the plant and within the City of Detroit. A detailed analysis was made of the types and ages of the buildings in the service area as a basis for establishing loads. The analysis of the power plant established possible modifications to the turbines to serve the load in the area. Based upon the service area data and plant retrofit schemes, a distribution system was developed incrementally over a 20-y period. An economic analysis of the system was performed to provide cash flows and payback periods for a variety of energy costs, system costs, and escalation rates to determine the economic viability of the system analyzed. The legal and regulatory requirements required of the district heating and cooling system owner in Michigan were also analyzed to determine what conditions must be met to own and operate the system.

  7. The Forest Energy Chain in Tuscany: Economic Feasibility and Environmental Effects of Two Types of Biomass District Heating Plant

    Directory of Open Access Journals (Sweden)

    Claudio Fagarazzi

    2014-09-01

    Full Text Available The purpose of this study was to examine two biomass district heating plants operating in Tuscany, with a specific focus on the ex-post evaluation of their economic and financial feasibility and of their environmental benefits. The former biomass district heating plant supplies only public users (Comunità Montana della Lunigiana, CML: administrative body that coordinates the municipalities located in mountain areas, the latter supplies both public and private users (Municipality of San Romano in Garfagnana. Ex-post investment analysis was performed to check both the consistency of results with the forecasts made in the stage of the project design and on the factors, which may have reduced or jeopardized the estimated economic performance of the investment (ex-ante assessment. The results of the study point out appreciable results only in the case of biomass district heating plants involving private users and fuelled by biomasses sourced from third parties. In this case, the factors that most influence ex-post results include the conditions of the woody biomass local market (market prices, the policies of energy selling prices to private users and the temporal dynamics of private users’ connection. To ensure the consistency of ex-post economic outcome with the expected results it is thus important to: (i have good knowledge of the woody local market; (ii define energy selling prices that should be cheap for private users but consistent with energy production costs and (iii constrain private users beforehand to prevent errors in the plant design and in the preliminary estimate of return on investment. Moreover, the results obtained during the monitoring activities could help in providing information on the effectiveness of the supporting measures adopted and also to orient future choices of policy makers and particularly designers, to identify the most efficient configuration of district heating organization for improving energy and

  8. Detection and location of leaks in district heating steam systems: Survey and review of current technology and practices

    Energy Technology Data Exchange (ETDEWEB)

    Kupperman, D.S.; Raptis, A.C.; Lanham, R.N.

    1992-03-01

    This report presents the results of a survey undertaken to identify and characterize current practices for detecting and locating leaks in district heating systems, particular steam systems. Currently used technology and practices are reviewed. In addition, the survey was used to gather information that may be important for the application of acoustic leak detection. A few examples of attempts to locate leaks in steam and hot water pipes by correlation of acoustic signals generated by the leaks are also discussed.

  9. District heating systems - the necessary infrastructure for geothermal energy; Fern- und Nahwaermesysteme - notwendige Infrastruktur fuer die Geothermie

    Energy Technology Data Exchange (ETDEWEB)

    Schoenberg, I. [Inst. fuer Umwelt-, Sicherheits- und Energietechnik e.V. (UMSICHT), Oberhausen (Germany)

    1997-12-01

    The contribution discusses the future chances of geothermal energy use with cost-optimized systems of geothermal energy + cogeneration + district heating and with the focus on innovation instead of state funding. (orig./AKF) [Deutsch] Der Beitrag bezieht sich auf die zukuenftigen Chancen der Geothermie, die eine kostenoptimierte Systemloesung Geothermie + KWK + Nah-/Fernwaerme sowie durch Mut zur Innovation und nicht durch Foerderung bestimmt werden. (orig./AKF)

  10. District heating and cooling systems for communities through power plant retrofit and distribution network, city of Piqua, Ohio

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-01-01

    The feasibility analysis and evaluation of the Piqua, Ohio District Heating and Cooling Demonstration program is being conducted by the Piqua Municipal Power Co., the Piqua Law Dept., the Public Works Dept., a firm of economic analysts, and the Georgia Tech Engineering Dept. This volume contains information on the organization and composition of the demonstration team; characterization of the Piqua community; and the technical, environmental, institutional; financial, and economic assessments of the project. (LCL)

  11. Measuring sustainability as a programming tool for health sector investments: report from a pilot sustainability assessment in five Nepalese health districts.

    Science.gov (United States)

    Sarriot, Eric; Ricca, Jim; Ryan, Leo; Basnet, Jagat; Arscott-Mills, Sharon

    2009-01-01

    Sustainability is a critical determinant of scale and impact of health sector development assistance programs. Working with USAID/Nepal implementing partners, we adapted a sustainability assessment framework to help USAID test how an evaluation tool could inform its health portfolio management. The essential first process step was to define the boundaries of the local system being examined. This local system-the unit of analysis of the study-was defined as the health district.We developed a standardized set of assessment tools to measure 53 indicators. Data collection was carried out over 4 weeks by a Nepalese agency. Scaling and combining indicators into six component indices provided a map of progress toward sustainable maternal, child, health, and family planning results for the five districts included in this pilot study, ranked from "no sustainability" to "beginning of sustainability."We conclude that systematic application of the Sustainability Framework could improve the health sector investment decisions of development agencies. It could also give districts an information base on which to build autonomy and accountability. The ability to form and test hypotheses about the sustainability of outcomes under various funding strategies-made possible by this approach-will be a prerequisite for more efficiently meeting the global health agenda.

  12. DENINT power plant cost benefit analysis code: Analysis of methane fuelled power plant/district heating system

    International Nuclear Information System (INIS)

    Cincotti, V.; D'Andrea, A.

    1989-07-01

    The DENINT power plant cost benefit analysis code takes into consideration, not only power production costs at the generator terminals, but also, in the case of cogeneration, the costs of the fuel supply and heat and power distribution systems which depend greatly on the location of the plant. The code is able to allow comparisons of alternatives with varying annual operation hours, fuel cost increases, and different types of fossil fuels and production systems. For illustrative purposes, this paper examines two methane fired cogeneration plant/district heating alternatives

  13. A Comparative Study on Substation Types and Network Layouts in Connection with Low-Energy District Heating Systems

    DEFF Research Database (Denmark)

    Tol, Hakan; Svendsen, Svend

    2012-01-01

    The study deals with low-energy district heating (DH) networks operating in low temperatures such as 55 °C in terms of supply and 25 °C in terms of return. The network layout, additional booster pumps, and different substation types such as storage tanks either equipped or not equipped in domestic...... hot water production site were examined. Effects of booster pumps on pipe dimensions in the latter case were investigated. Temperature drops during the summer months due to low heat demands of consumers were explored. Use of approaches such as looped networks and branched network layouts with bypasses...

  14. Projected configuration of a coal-fired district heating source on the basis of comparative technical-economical optimization analysis

    Directory of Open Access Journals (Sweden)

    Tańczuk Mariusz

    2017-01-01

    Full Text Available District heating technologies should be efficient, effective and environmentally friendly. The majority of the communal heating systems in Poland produce district hot water in coal-fired boilers. A large number of them are considerably worn out, low-efficient in the summer time and will not comply with forthcoming regulations. One of the possible solution for such plants is repowering with new CHP systems or new boilers fuelled with fuels alternative to coal. Optimisation analysis of the target configuration of municipal heat generating plant is analysed in the paper. The work concerns repowering the existing conventional heat generating plant according to eight different scenarios of the plant configuration meeting technical and environmental requirements forecasted for the year of 2035. The maximum demand for heat of the system supplied by the plant is 185 MW. Taking into account different technical configurations on one side, and different energy and fuel prices on the other side, the comparative cost-benefits analysis of the assumed scenarios has been made. The basic economical index NPV (net present value has been derived for each analysed scenario and the results have been compared and discussed. It was also claimed that the scenario with CHP based on ICE engines is optimal.

  15. Projected configuration of a coal-fired district heating source on the basis of comparative technical-economical optimization analysis

    Science.gov (United States)

    Tańczuk, Mariusz; Radziewicz, Wojciech; Olszewski, Eligiusz; Skorek, Janusz

    2017-10-01

    District heating technologies should be efficient, effective and environmentally friendly. The majority of the communal heating systems in Poland produce district hot water in coal-fired boilers. A large number of them are considerably worn out, low-efficient in the summer time and will not comply with forthcoming regulations. One of the possible solution for such plants is repowering with new CHP systems or new boilers fuelled with fuels alternative to coal. Optimisation analysis of the target configuration of municipal heat generating plant is analysed in the paper. The work concerns repowering the existing conventional heat generating plant according to eight different scenarios of the plant configuration meeting technical and environmental requirements forecasted for the year of 2035. The maximum demand for heat of the system supplied by the plant is 185 MW. Taking into account different technical configurations on one side, and different energy and fuel prices on the other side, the comparative cost-benefits analysis of the assumed scenarios has been made. The basic economical index NPV (net present value) has been derived for each analysed scenario and the results have been compared and discussed. It was also claimed that the scenario with CHP based on ICE engines is optimal.

  16. Influence of legislative conditioned changes in waste management on economic viability of MSW-fuelled district heating system: Case study

    Directory of Open Access Journals (Sweden)

    Tomić Tihomir

    2016-01-01

    Full Text Available District heating systems represents one of the ways by which the European Union is trying to reach set goals in energy efficiency and security field. These systems allow the use of different energy sources including local energy sources such as waste and biomass. This paper provides economic viability assessment of using these fuels in the district heating system. Economic evaluation is based on regression analysis from data of existing plants and on the locally dependent data. Some of parameters that are dependent of local parameters are price and available fuel quantity, therefore these values are separately modelled; biomass as a function of location of the plant while municipal waste as a function of location and the time changes in waste quantity and composition which depend of socio-economic trends and legislation. This methodology is applied on the case of district heating plants in the City of Zagreb where internal rates of return are calculated for four considered scenarios. Results indicate that waste powered plant can improve its profitability by co-combusting other local wastes while economic viability is achieved by introduction of region wide waste management system. Reducing plant capacity, based on prognosis of waste generation, showed that these plants can be competitive with biomass plants.

  17. Optimal Design of Cogeneration Systems in Industrial Plants Combined with District Heating/Cooling and Underground Thermal Energy Storage

    Directory of Open Access Journals (Sweden)

    Vincenzo Dovì

    2011-12-01

    Full Text Available Combined heat and power (CHP systems in both power stations and large plants are becoming one of the most important tools for reducing energy requirements and consequently the overall carbon footprint of fundamental industrial activities. While power stations employ topping cycles where the heat rejected from the cycle is supplied to domestic and industrial consumers, the plants that produce surplus heat can utilise bottoming cycles to generate electrical power. Traditionally the waste heat available at high temperatures was used to generate electrical power, whereas energy at lower temperatures was either released to the environment or used for commercial or domestic heating. However the introduction of new engines, such as the ones using the organic Rankine cycle, capable of employing condensing temperatures very close to the ambient temperature, has made the generation of electrical power at low temperatures also convenient. On the other hand, district heating is becoming more and more significant since it has been extended to include cooling in the warm months and underground storage of thermal energy to cope with variable demand. These developments imply that electric power generation and district heating/cooling may become alternative and not complementary solutions for waste energy of industrial plants. Therefore the overall energy management requires the introduction of an optimisation algorithm to select the best strategy. In this paper we propose an algorithm for the minimisation of a suitable cost function, for any given variable heat demand from commercial and domestic users, with respect to all independent variables, i.e., temperatures and flowrates of warm fluid streams leaving the plants and volume and nature of underground storage. The results of the preliminary process integration analysis based on pinch technology are used in this algorithm to provide bounds on the values of temperatures.

  18. Global carbon impacts of using forest harvest residues for district heating in Vermont

    International Nuclear Information System (INIS)

    McLain, H.A.

    1998-01-01

    Forests in Vermont are selectively logged periodically to generate wood products and useful energy. Carbon remains stored in the wood products during their lifetime and in fossil fuel displaced by using these products in place of energy-intensive products. Additional carbon is sequestered by new forest growth, and the forest inventory is sustained using this procedure. A significant portion of the harvest residue can be used as biofuel in central plants to generate electricity and thermal energy, which also displaces the use of fossil fuels. The impact of this action on the global carbon balance was analyzed using a model derived from the Graz/Oak Ridge Carbon Accounting Model (GORCAM). The analysis showed that when forests are harvested only to manufacture wood products, more than 100 years are required to match the sequestered carbon present if the forest is left undisturbed. If part of the harvest residue is collected and used as biofuel in place of oil or natural gas, it is possible to reduce this time to about 90 years, but it is usually longer. Given that harvesting the forest for products will continue, carbon emission benefits relative to this practice can start within 10 to 70 years if part of the harvest residue is used as biofuel. This time is usually higher for electric generation plants, but it can be reduced substantially by converting to cogeneration operation. Cogeneration makes possible a ratio of carbon emission reduction for district heating to carbon emission increase for electricity generation in the range of 3 to 5. Additional sequestering benefits can be realized by using discarded wood products as biofuels

  19. Thermodynamic and economic evaluations of a geothermal district heating system using advanced exergy-based methods

    International Nuclear Information System (INIS)

    Tan, Mehmet; Keçebaş, Ali

    2014-01-01

    Highlights: • Evaluation of a GDHS using advanced exergy-based methods. • Comparison of the results of the conventional and advanced exergy-based methods. • The modified exergetic efficiency and exergoeconomic factor are found as 45% and 13%. • Improvement and total cost-savings potentials are found to be 3% and 14%. • All the pumps have the highest improvement potential and total cost-savings potential. - Abstract: In this paper, a geothermal district heating system (GDHS) is comparatively evaluated in terms of thermodynamic and economic aspects using advanced exergy-based methods to identify the potential for improvement, the interactions among system components, and the direction and potential for energy savings. The actual operational data are taken from the Sarayköy GDHS, Turkey. In the advanced exergetic and exergoeconomic analyses, the exergy destruction and the total operating cost within each component of the system are split into endogenous/exogenous and unavoidable/avoidable parts. The advantages of these analyses over conventional ones are demonstrated. The results indicate that the advanced exergy-based method is a more meaningful and effective tool than the conventional one for system performance evaluation. The exergetic efficiency and the exergoeconomic factor of the overall system for the Sarayköy GDHS were determined to be 43.72% and 5.25% according to the conventional tools and 45.06% and 12.98% according to the advanced tools. The improvement potential and the total cost-savings potential of the overall system were also determined to be 2.98% and 14.05%, respectively. All of the pumps have the highest improvement potential and total cost-savings potential because the pumps were selected to have high power during installation at the Sarayköy GDHS

  20. District heating (DH) network design and operation toward a system-wide methodology for optimizing renewable energy solutions (SMORES) in Canada: A case study

    DEFF Research Database (Denmark)

    Dalla Rosa, A.; Boulter, R.; Church, K.

    2012-01-01

    This paper discusses the opportunities and challenges of implementing District Heating (DH) in Canada, with focus on the network design and operation. We selected for case study an urban area in Ottawa. First, we proved that the medium-temperature district heating (MTDH) (70 C Tsupply 90 C) had...... of lowtemperature district heating (LTDH) should be considered, thanks to the capability of including more renewable energy and excess industrial waste heat. Next, the simulations show that DH can be implemented to supply present heating loads with medium temperature DH, and operate in the future at low temperature...... in Canada. The paper discusses critical issues and quantifies the performance of design concepts for DH supply to low heat density areas. DH is a fundamental energy infrastructure and is part of the solution for sustainable energy planning in Canadian communities....

  1. Solar district heating system `Schillerstrasse` in Schwaebisch-Gmuend; Solare Nahwaerme ``Schillerstrasse`` in Schwaebisch Gmuend

    Energy Technology Data Exchange (ETDEWEB)

    Kuebler, R. [Steinbeis-Transferzentrum Energie-, Gebaeude- und Solartechnik, Stuttgart (Germany); Mangold, D. [Stuttgart Univ. (Germany). Inst. fuer Thermodynamik und Waermetechnik

    1998-12-31

    The construction project Schillerstrasse in Schwaebisch-Gmuend was planned and realised by the Siedlungswerk Stuttgart from 1993 until 1996. Like in earlier projects in Ravensburg and Koengen the Siedlungswerk wanted to use new technologies in the field of thermal insulation and heat supply at the construction of this new residential area in order to stay considerably below the former construction standards (WSVO 1982). One part of this energy concept is a large solar plant to support warm water supply. Good experience had been made with flat solar collectors at the three plants in Ravensburg and Koengen. In Schwaebisch-Gmuend vacuum pipe collectors were utilised for the first time. They were the only type of collectors which could be installed on the flat roofs without being visible from the ground. The solar-assisted district heating system was put in operation in May 1996. A new method that controls the system by measuring data acquisition enabled to measure and optimise the thermal performance of the plant. At the beginning of 1998 the plant was modified in order to improve the use of the solar plant. (orig.) [Deutsch] Das Bauvorhaben Schillerstrasse in Schwaebisch Gmuend wurde in den Jahren 1993-1996 vom Siedlungswerk Stuttgart geplant und gebaut. Aehnlich wie bei frueheren Projekten in Ravensburg und Koengen war es das Ziel des Siedlungswerks, in diesem Neubauvorhaben neue Wege beim Waermeschutz und bei der Waermeversorgung der Wohnanlage zu gehen, um den damaligen Baustandard (WSVO 1982) deutlich zu unterschreiten. Ein Element dieses Energiekonzepts ist eine grosse Solaranlage zur Unterstuetzung der Warmwasserbereitung. Nach guten Erfahrungen mit Flachkollektoren in den drei Anlagen in Ravensburg und Koengen wurden in Schwaebisch Gmuend zum ersten Mal Vakuum-Roehrenkollektoren eingesetzt. Fuer die Wahl der Vakuumroehren waren nicht zuletzt die stadtpolitischen Randbedingungen ausschlaggebend, die nur eine von unten nicht sichtbare Aufstellung auf dem

  2. Waste incineration within the Swedish district heating systems - Sub-Project 4; Avfallsfoerbraenning inom Sveriges fjaerrvaermesystem - Delprojekt 4 inom projektet Perspektiv paa framtida avfallsbehandling

    Energy Technology Data Exchange (ETDEWEB)

    Haraldsson, Maarten; Holmstroem; David

    2012-07-01

    Waste incineration within the Swedish district heating systems is one of the five sub-projects within the project Perspectives on sustainable waste treatment. The goal of this project is to evaluate the economic potential for waste incineration in the Swedish district heating systems. With the current expansion of incineration, we may relatively soon reach an upper limit for what is demanded by the Swedish district heating systems. How much more waste incineration that is economically attractive to build is of great importance for the development of the Swedish waste system, not least for the alternatives to incineration as for example biogas production. With continued rising quantities of waste and stagnant demand for waste incineration from the district heating systems, today's surplus of treatment capacity may change the market picture for other waste treatment options. How much more waste incineration requested and how quickly the market reaches this level is studied in this project.

  3. District heating and cooling systems for communities through power plant retrofit distribution network. Final report, September 1, 1978-May 31, 1979

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-10-01

    This Final Report (Volume 2) of Phase 1 of District Heating for Communities Through Power Plant Retrofit Distribution Network contains 3 tasks: (1) Demonstration Team; (2) Identify Thermal Energy Sources and Potential Service Areas; and (3) Energy Market Analysis. Task 2 consists of estimating the thermal load within 5 and 10 miles of Public Service Electric and Gas Company steam power plants, Newark, New Jersey; estimating the costs of supplying thermal services to thermal loads of varying densities; a best case economic analysis of district heating for single-family homes; and some general comments on district-heating system design and development. Task 3 established the potential market for district heating that exists within a 5-mile radius of the selected generating stations; a sample of the questionnaire sent to the customers are shown. (MCW)

  4. Extension and improvement of Central Station District heating budget period 1 and 2, Krakow Clean Fossil Fuels and Energy Efficiency Program. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-07-01

    Project aim was to reduce pollution levels in the City of Krakow through the retirement of coal-fired (hand and mechanically-stoked) boiler houses. This was achieved by identifying attractive candidates and connecting them to the Krakow district heating system, thus permitting them to eliminate boiler operations. Because coal is less costly than district hot water, the district heating company Miejskie Przedsiebiorstwo Energetyki Cieplnej S.A., henceforth identified as MPEC, needed to provide potential customers with incentives for purchasing district heat. These incentives consisted of offerings which MPEC made to the prospective client. The offerings presented the economic and environmental benefits to district heating tie-in and also could include conservation studies of the facilities, so that consumption of energy could be reduced and the cost impact on operations mitigated. Because some of the targeted boiler houses were large, the capacity of the district heating network required enhancement at strategic locations. Consequently, project construction work included both enhancement to the district piping network as well as facility tie-ins. The process of securing new customers necessitated the strengthening of MPEC`s competitive position in Krakow`s energy marketplace, which in turn required improvements in marketing, customer service, strategic planning, and project management. Learning how US utilities address these challenges became an integral segment of the project`s scope.

  5. Heat supply to low energy dwellings in district heating areas. Analyses of CO{sub 2} emissions and electricity supply security; Varmeforsyning til lavenergiboliger i omraader med fjernvarmekonsesjon. Analyser av CO{sub 2}-utslipp og forsyningssikkerhet for elektrisitet

    Energy Technology Data Exchange (ETDEWEB)

    Thyholt, Marit

    2006-07-01

    Building low energy dwellings in large development projects is a new situation in Norway. The municipalities have to a little extent analyzed the consequences of this new housing standard with respect to the energy supply to such areas, and how this standard may change the plans for new or extended district heat production. In the provision about the mandatory connection to district heating plants, and the appendant provision related to a heating system that can utilize district heat, the district heat supply and the heat demand are not seen in connection. The objective of this dissertation is to provide the municipalities with a basis for decision making in the processing of applications concerning dispensation from the mandatory connection or the heating system requirement for dwellings with low heat demand. This basis for decision making is based on the national aim of reducing carbon dioxide (CO{sub 2}) emissions and of improving the electricity supply security. This summary provides an abstract from the discussion of the legislation as an incentive or barrier for building low energy dwellings. An abstract from a survey among construction firms concerning the motivation for building low energy dwellings is also included. In addition, the summary provides a comprehensive abstract of the results from the CO{sub 2} emission calculations, and the basis for these calculations. Introductorily a brief background of the national focus on energy savings and increased use of hydronic heating, including district heat, is given.

  6. UPEI (University of Prince Edward Island) wood chip boiler to feed second Charlottetown area district heating system

    Energy Technology Data Exchange (ETDEWEB)

    1987-09-01

    A new $4.3 million district heating system will deliver heat to 31 subscribers from UPEI's wood-fired heating plant. The plan is to convert UPEI's own campus-wide heat distribution system from steam to more efficient hot water. The total plant output is 13.7 MW, enough to heat the campus and the 31 subcribers' buildings. During the 1987-88 fiscal year, the more northern part of the system will be completed. A year later the system will be extended south. When finished, the project will displace nearly 2 million l of fuel oil annually with just over 7000 green tonnes of wood chips. Hot water from the UPEI boiler plant travels along each route though buried insulated pipes. At the end of a run, the water reverses direction and returns to the boiler in another insulated pipe. It passes through small cylindrical heat exchangers in each building. Boiler and burner maintenance costs are eliminated. Once the user is familiar with the system, the old boiler and hot water tanks can be removed - making space available for other purposes. District heating is virtually noiseless. Insurance costs go down in many cases when boilers and combustion systems are no longer used. The Island's currently underutilized wood resource will be put to better use. These woodchips are made from wood that has been damaged by budworm and other diseases, or wood that is overmature. The project has sound environmental benefits ranging from reduced sulpher emissions to the possible long-term benefit of eliminating a number of underground fuel storage tanks and their potential for leaks.

  7. Design of serially connected ammonia-water hybrid absorption-compression heat pumps for district heating with the utilisation of a geothermal heat source

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2016-01-01

    to supply 7.2 MW heat at 85 °C utilizing a geothermal heat source at 73 °C. Both the heat source and heat sink experience a large temperature change over the heat transfer process, of which a significant part may be achieved by direct heat exchange. First a generic study with a simple representation...

  8. User manual for AQUASTOR: a computer model for cost analysis of aquifer thermal energy storage coupled with district heating or cooling systems. Volume I. Main text

    Energy Technology Data Exchange (ETDEWEB)

    Huber, H.D.; Brown, D.R.; Reilly, R.W.

    1982-04-01

    A computer model called AQUASTOR was developed for calculating the cost of district heating (cooling) using thermal energy supplied by an aquifer thermal energy storage (ATES) system. The AQUASTOR model can simulate ATES district heating systems using stored hot water or ATES district cooling systems using stored chilled water. AQUASTOR simulates the complete ATES district heating (cooling) system, which consists of two principal parts: the ATES supply system and the district heating (cooling) distribution system. The supply system submodel calculates the life-cycle cost of thermal energy supplied to the distribution system by simulating the technical design and cash flows for the exploration, development, and operation of the ATES supply system. The distribution system submodel calculates the life-cycle cost of heat (chill) delivered by the distribution system to the end-users by simulating the technical design and cash flows for the construction and operation of the distribution system. The model combines the technical characteristics of the supply system and the technical characteristics of the distribution system with financial and tax conditions for the entities operating the two systems into one techno-economic model. This provides the flexibility to individually or collectively evaluate the impact of different economic and technical parameters, assumptions, and uncertainties on the cost of providing district heating (cooling) with an ATES system. This volume contains the main text, including introduction, program description, input data instruction, a description of the output, and Appendix H, which contains the indices for supply input parameters, distribution input parameters, and AQUASTOR subroutines.

  9. Impact of different improvement measures on the thermal performance of a solar collector field for district heating

    DEFF Research Database (Denmark)

    Bava, Federico; Furbo, Simon

    2018-01-01

    The paper describes the impact of different measures to improve the thermal performance of a solar heating plant for district heating applications. The impact of the different measures was evaluated through a validated TRNSYS-Matlab model. The model included details such as effect of the flow...... regime in the absorber pipes on the collector efficiency, flow distribution in the collector field, thermal capacity of the pipes and shadows from row to row. The improvement measures included variation of the operating temperatures, accurate input to the control strategy, feedback control on the outlet...... temperature of the collector field, control strategy based on weather forecast and use of different heat transfer fluids. The results showed that accurate input to the control strategy improved the yearly energy output of the plant by about 3%. If accurate input is not technically or economically feasible...

  10. District heating for Switzerland - Project development; Projektentwicklung Fernwaerme Schweiz - Abwaermenutzung aus (de)zentralen Quellen der Industrie und Umwelt (Schlussbericht Projektphase 1)

    Energy Technology Data Exchange (ETDEWEB)

    Oppermann, G. [Verband Fernwaerme Schweiz, Niederrohrdorf (Switzerland); Gutzwiller, S. [Eicher und Pauli AG, Planer fuer Energie- und Gebaeudetechnik, Liestal (Switzerland); Mueller, E. A. [EnergieSchweiz fuer Infrastrukturanlagen, Berne (Switzerland)

    2010-05-15

    This final report for 2010 for the Swiss Federal Office of Energy (SFOE) deals with the achievements of the first phase of a project concerning district heating systems in Switzerland. The Swiss District Heating Association (VFS) aims to initiate district heating projects using a four-phase project. Phase 1 involved the identification of potential projects: Locations for the use of waste heat, environmental heat, wood and biomass were identified. The further phases will involve possible investors, the development of concrete projects and, finally, their realisation. The report describes work to be done, the project organisation, presents basic data needed for the project phases, discusses regional planning aspects, reviews aids such as GPS data and 'excel' spread sheets and geographic aspects. Further topics addressed in the report include results achieved, the search for investors and external communication. The report is completed with recommendations and four appendices.

  11. Annual measured and simulated thermal performance analysis of a hybrid solar district heating plant with flat plate collectors and parabolic trough collectors in series

    DEFF Research Database (Denmark)

    Tian, Zhiyong; Perers, Bengt; Furbo, Simon

    2017-01-01

    in large solar heating plants for a district heating network, a hybrid solar collector field with 5960 m2 flat plate collectors and 4039 m2 parabolic trough collectors in series was constructed in Taars, Denmark. The design principle is that the flat plate collectors preheat the return water from...... the district heating network to about 70 °C and then the parabolic trough collectors would heat the preheated water to the required supply temperature of the district heating network. Annual measured and simulated thermal performances of both the parabolic trough collector field and the flat plate collector...... field are presented in this paper. The thermal performance of both collector fields with weather data of a Design Reference Year was simulated to have a whole understanding of the application of both collectors under Danish climate conditions as well. These results not only can provide a design basis...

  12. District heating and cooling systems for communities through power plant retrofit distribution network. Volume 3. Final report, September 1, 1978-May 31, 1979

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-10-01

    This final report of Phase I of the study presents Task 4, Technical Review and Assessment. The most-promising district-heating concept identified in the Phase I study for the Public Service Electric and Gas Company, Newark, New Jersey, is a hot-water system in which steam is extracted from an existing turbine and used to drive a new, small backpressure turbine-generator. The backpressure turbine provides heat for district heating and simultaneously provides additional electric-generating capacity to partially offset the capacity lost due to the steam extraction. This approach is the most-economical way to retrofit the stations studied for district heating while minimizing electric-capacity loss. Nine fossil-fuel-fired stations within the PSE and G system were evaluated for possibly supplying heat for district heating and cooling in cogeneration operations, but only three were selected to supply the district-heating steam. They are Essex, Hudson, and Bergen. Plant retrofit, thermal distribution schemes, consumer-conversion scheme, and consumer-metering system are discussed. Extensive technical information is provided in 16 appendices, additional tables, figures, and drawings. (MCW)

  13. A comparative study on substation types and network layouts in connection with low-energy district heating systems

    International Nuclear Information System (INIS)

    Tol, Hakan İbrahim; Svendsen, Svend

    2012-01-01

    Highlights: ► Heat loads determined with simultaneity factor result in reduced diameters employed. ► We examine the effect of substation types and booster pumps on pipe diameters. ► Network layouts were investigated to prevent temperature drop at summer months. ► Operational changes occurred at network with changing heat demand profiles. - Abstract: The study deals with low-energy District Heating (DH) networks operating in low temperatures such as 55 °C in terms of supply and 25 °C in terms of return. The network layout, additional booster pumps, and different substation types such as storage tanks either equipped or not equipped in domestic hot water production site were examined. Effects of booster pumps on pipe dimensions in the latter case were investigated. Temperature drops during the summer months due to low heat demands of consumers were explored. Use of approaches such as looped networks and branched network layouts with bypasses for end-consumers were also studied, heat loss from these networks and the drop in temperature in the heat-carrier-supply medium being compared.

  14. An Analysis of the Impact of Heat Waves in Labor and Crop Productivity in the Agricultural Sector in California

    Science.gov (United States)

    Castillo, F.; Wehner, M. F.; Gilless, J. K.

    2017-12-01

    California agriculture is an important economic activity for the state. California leads the nation in farms sales since 1950. In addition, agricultural employment in California reached approximately 410,000. Production of many fruits and vegetables is labor intensive and labor costs represent anywhere from 20% to 40% of total production costs. In additon, agricutlural production growth has been the highest for labor intensive crops such as berries (all types) and nuts. Given the importance of the agricultural sector and the labor component whithin it, the analysis of the impact of climate change on the agricultural sector of California becomes imperative. Heat waves are a weather related extreme that impact labor productivity, specially outdoor labor producitivity. We use crop production function analysis that incorporates socio economic variables such as crop prices, total acreage, production levels and harvest timiline with climate related variables such as an estimated Heat Index (HI) to analize the impact of heat waves on crop production via an impact on labor productivity for selected crops in the Central and Imperial Valleys in California. The analysis finds that the impact of heat waves varies by the degree of labor intensity of the crop and the relative intensity of the heat wave.

  15. Tool for economic and environmental analysis of hybrid plants for district cooling and district heating - 'District cooling 2.0'. Final report and user guide; Vaerktoej til oekonomisk og miljoemaessig analyse af hybridanlaeg til fjernkoeling og fjernvarme. Fjernkoel 2.0. Slutrapport og brugermanual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-03-15

    The purpose of the tool is to help bring district cooling solutions into consideration by facilitating rapid technical / economic and environmental analysis of district cooling solutions - also with heat pump operation. The tool is a screening tool intended for specific cases with actual data from reality. The tool can analyze the simultaneous production of heat and cooling, and use of storage can make district cooling even more profitable. It is also possible to analyze the importance of flexible electricity and heating prices and see how they can be utilized, including the calculation of the probable prices on heating and cooling, and investments. The tool can make calculations on the following plant types: - Systems with only cooling without cold storage; - Systems with only cooling with cold storage; - Systems with cooling and heating controlled by cooling - with heat storage; - Systems with heating and cooling controlled by heating - with heating and cooling storage; - Systems with cooling and heating with optimized management - with heat storage. The tool can also be used to make general assessments, for example, to analyze the importance of flexible electricity and heating prices of typical district cooling systems, and for that matter, heat pump systems. (LN)

  16. Anomalies jointing in the Laguna Blanca area (Rocha district) about of radiometric anomaly sector with thorium characteristic

    International Nuclear Information System (INIS)

    Lara, P.

    1986-01-01

    In the following lines are sumarized the prospection works carried out on anomalous radiometric sectors located at the Department of Rocha (Uruguay) Its toriferous feature and the likely metallogenetic model to which they are associated are also developed

  17. Impact of different national biomass policies on investment costs of biomass district heating plants. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-04-01

    The BIO-COST project - co-ordinated by E.V.A. - was funded by the European Commission's THERMIE Type B Programme. The objective of BIO-COST was to analyse the impact of national biomass policies on the investment costs of biomass district heating (DH) plants. The European comparison should help identifying measures to reduce investment costs for biomass DH plants and/or components down to a 'best practice' level. The investigation is based on the comparison of 20 biomass DH plants by country, with Denmark and Sweden having mainly high energy taxes as driver, while Austria and France rely mainly on subsidy systems. The results of BIO-COST show, that governmental policies can have a big impact especially on grid and buildings costs, effecting of course the overall costs of the plant enormously. Emission standards have their effects especially on the costs for technical equipment, however, this fact was not reflected in the BIO-COST data. The results do not show a clear advantage of either the energy tax approach or the subsidy approach: The French subsidy approach leads to fairly low cost levels compared to the Danish tax approach, while the Swedish tax approach seems to yield the lowest cost level. On the other hand the Austrian subsidy approach seems to intercrease investment costs. In principle both the tax as the subsidy approach can lead to the same effect: a project is calculated in such a way, that it just meets economic breakeven. This is typically the case when the project is not carried out by a private enterprise but by an operator aiming at enhanced public welfare (e.g. co-operative, municipality). In this case a subsidy model might yield more possibilities to encourage an economically efficient development, than a tax. Instead of giving subsidies as a fixed percentage of investments they could be adjusted to the actual needs of the project as proven by a standardised calculation. Of course this can create the incentive to expect higher

  18. Development and validation of a detailed TRNSYS-Matlab model for large solar collector fields for district heating applications

    DEFF Research Database (Denmark)

    Bava, Federico; Furbo, Simon

    2017-01-01

    This study describes the development of a detailed TRNSYS-Matlab model to simulate the behavior of a large solar collector field for district heating application. The model includes and investigates aspects which are not always considered by simpler models, such as flow distribution in the differ......This study describes the development of a detailed TRNSYS-Matlab model to simulate the behavior of a large solar collector field for district heating application. The model includes and investigates aspects which are not always considered by simpler models, such as flow distribution...... in the different rows, effect of the flow regime on the collector efficiency, thermal capacity of the components and effect of shadows from row to row. The model was compared with measurements from a solar collector field and the impact of each aspect was evaluated. A good agreement between model and measurements...... programming and computing time. Thermal capacity was worth being considered only for the bulkier components, such as the longer distribution and transmission pipes. The actual control strategy, which regulates the flow rates in the solar heating plant, was accurately reproduced in the model, as proved...

  19. Matching design and layout of the nuclear heating station AST-500 to the district heating network conditions in the GDR

    International Nuclear Information System (INIS)

    Luetzow, K.; Bordihn, S.

    1988-01-01

    Nuclear heating stations provide one possibility of supplying nuclear heat. They are uniquely intended for heat supply. The well-known Soviet nuclear heating station AST-500 with an output temperature of 150 0 C in the network pipes is below the value designed for some heat supply systems in the GDR. On the basis of a general method applicable to the choice of optimum parameters, proposals are placed for optimally matching design and layout of the AST-500 station to higher output temperatures. Minimization of the difference in expenses between the modified version and the well-known basic version of the AST-500 station has been used as the objective function of optimization. (author)

  20. Heat Roadmap Europe: Identifying strategic heat synergy regions

    International Nuclear Information System (INIS)

    Persson, U.; Möller, B.; Werner, S.

    2014-01-01

    This study presents a methodology to assess annual excess heat volumes from fuel combustion activities in energy and industry sector facilities based on carbon dioxide emission data. The aim is to determine regional balances of excess heat relative heat demands for all third level administrative regions in the European Union (EU) and to identify strategic regions suitable for large-scale implementation of district heating. The approach is motivated since the efficiency of current supply structures to meet building heat demands, mainly characterised by direct use of primary energy sources, is low and improvable. District heating is conceived as an urban supply side energy efficiency measure employable to enhance energy system efficiency by increased excess heat recoveries; hereby reducing primary energy demands by fuel substitution. However, the importance of heat has long been underestimated in EU decarbonisation strategies and local heat synergies have often been overlooked in energy models used for such scenarios. Study results indicate that 46% of all excess heat in EU27, corresponding to 31% of total building heat demands, is located within identified strategic regions. Still, a realisation of these rich opportunities will require higher recognition of the heat sector in future EU energy policy. - Highlights: • EU27 energy and industry sector heat recycling resources are mapped and quantified. • Target regions for large-scale implementation of district heating are identified. • 46% of total EU27 excess heat volume is seized in 63 strategic heat synergy regions. • Large urban zones have lead roles to play in transition to sustainability in Europe. • Higher recognition of heat sector is needed in future EU energy policy for realisation

  1. FOLA - the district heat supply project for the Olten-Aarau region

    International Nuclear Information System (INIS)

    Utzinger, E.

    1986-01-01

    The FOLA project envisages supply of nuclear power station heat via pipe lines to communities in the Olten-Aarau region. The project is introduced with reference to environmental and oil saving advantages. Heat from the nuclear power station steam circuit converted via heat exchangers would be transmitted through pressurised hot water pipe line networks to user communities for extraction by heat exchangers at consumer installations. Some network details are discussed. The exact supply area is not yet finalised, but estimated heat loading is about 150 MW. Following further studies a construction and operating company could be formed, and heat delivery could commence in 1989. (H.V.H.)

  2. Optimum design of district heating: Application of a novel methodology for improved design of community scale integrated energy systems

    International Nuclear Information System (INIS)

    Sanaei, Sayyed Mohammad; Nakata, Toshihiko

    2012-01-01

    The purpose of this paper is to present a new tool for design of integrated energy systems. The initial choice of the energy system components and the way they should interact is a crucial decision which the outcome of the design heavily relies on. Use of a physical law (instead of engineering judgment) as the basis of the decision making is the main advantage of the proposed approach over conventional approaches for design of community scale energy systems. The methodology has been implemented for design of a district heating system for an existing district in arid region of Iran. The optimum level of interaction between the energy system components has been identified by employing an optimization algorithm seeking to minimize the overall cost of the energy system. Some of the relative merits of the optimum design comparing to the present energy system are 17% increase of the exergy efficiency, 10.8% reduction in the amount of CO 2 production per capita and 2% reduction in overall energy related costs. -- Highlights: ► We propose a novel tool for design of integrated energy systems. ► Proposed tool has the advantage of using a physical principle (exergy matching) to define the design scenarios. ► Optimum design of district heating system was found subject to variations in energy prices and heating devices’ efficiencies. ► Contrary to energy efficiency, exergy efficiency clearly points out the design with best energetic performance. ► Exergy optimum design becomes the feasible option as the energy prices tend to rise towards the international prices.

  3. A multi-fuel management model for a community-level district heating system under multiple uncertainties

    International Nuclear Information System (INIS)

    Fu, D.Z.; Zheng, Z.Y.; Shi, H.B.; Xiao, Rui; Huang, G.H.; Li, Y.P.

    2017-01-01

    In this study, an interval two-stage double-stochastic single-sided fuzzy chance-constrained programming model is developed for supporting fuel management of a community-level district heating system (DHS) fed with both traditional fossil fuels and renewable biofuels under multiple uncertainties. The proposed model is based on the integration of interval parameter programming and single-sided fuzzy chance-constrained programming within an improved stochastic programming framework to tackle the uncertainties expressed as crisp intervals, fuzzy relationship, and probability distributions. Through transforming and solving the model, the related fuzzy and stochastic information can be effectively reflected in the generated solutions. A real fuel management case of a DHS located in Junpu New District of Dalian is utilized to demonstrate the model applicability. The obtained solutions provides an effective linkage in terms of both ‘‘quality’’ and ‘‘quantity’’ aspects for fuel management under various scenarios associated with multiple factors, and thus can help the decision makers to identify desired fuel allotment patterns. Moreover, this study is also useful for decision makers to address the other challenges (e.g. the imbalance between fuel supply and demand, the contradiction between air-pollution emission and environmental protection, as well as the tradeoff between the total heating cost and system satisfaction degree) generated in the fuel management processes. - Highlights: • A feasible two-stage stochastic programming method is improved. • A multi-fuel management model is developed under multiple uncertainties. • The fuel supply pattern for a district heating system can be obtained. • The variation tendencies of the pollutant emissions are examined. • Tradeoff analyses between system satisfaction degree and cost are carried out.

  4. District heating and cooling systems for communities through power plant retrofit distribution network. Final report, September 1, 1978-May 31, 1979

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-10-01

    This volume presents information on the institutional factors, i.e., legal and regulatory aspects, a preliminary economic analysis, and a proposal for future studies on retrofitting existing thermal power plants so that they can supply heat for district heating and cooling systems for communities. (LCL)

  5. High-temperature pretreatment of biogas substrate by using district heating to increase the biogas production; Hoegtemperaturfoerbehandling av biogassubstrat med fjaerrvaerme foer oekad biogasproduktion

    Energy Technology Data Exchange (ETDEWEB)

    Del Pilar Castillo, Maria; Ascue, Johnny [JTI, Uppsala (Sweden); Olsson, Marcus; Henriksson, Gunilla; Nordman, Roger [SP, Boraas (Sweden)

    2011-12-15

    In this study, we have shown that pre-heating sludge from a waste water treatment plant can give a higher biogas production rate. However, pretreatment showed no effect on substrate from a biogas plant at the conditions tested in this study. The study has also shown that there is potential of using district heating in the biogas industry for thermal pretreatment of sludge.

  6. Load Prediction in District Heating Systems with Regard to Scenarios and Uncertainties in Weather; Lastprognoser foer fjaerrvaerme med haensyn till scenarier och osaekerheter i vaedret

    Energy Technology Data Exchange (ETDEWEB)

    Hedberg, Martin; Koppers, Gijs [Meteopolaris AB, Nacka (Sweden)

    2011-11-15

    The report shows, by means of load calculations on ensemble weather forecasts and subsequent production planning, that by a better optimization of the operation of district heating plants the costs of production of heat and electricity can be reduced. During a fifth of the time the saving potential is 5% or more.

  7. Expieriences On Low-Temperature District Heating In Lystrup – Denmark

    DEFF Research Database (Denmark)

    Thorsen, Jan Eric; Christiansen, Christian Holm; Brand, Marek

    2011-01-01

    reduction of heat consumption for individual buildings. This means ratio between net work heat loss and heat consumption in buildings will become even more important in future. To address this challenge low-temperature DH network concept is analysed and tested in real scale. This paper describes main...

  8. Sanitary hot water consumption patterns in commercial and industrial sectors in South Africa: Impact on heating system design

    International Nuclear Information System (INIS)

    Rankin, R.; Rousseau, P.G.

    2006-01-01

    A large amount of individual sanitary hot water consumers are present in the South African residential sector. This led to several studies being done on hot water consumption patterns in this sector. Large amounts of sanitary hot water are also consumed in the commercial sector in buildings such as hotels and in large residences such as those found in the mining industry. The daily profiles of sanitary hot water consumption are not related to any technical process but rather to human behavior and varying ambient conditions. The consumption of sanitary hot water, therefore, represents a challenge to the electrical utility because it is an energy demand that remains one of the biggest contributors to the undesirable high morning and afternoon peaks imposed on the national electricity supply grid. It also represents a challenge to sanitary hot water system designers because the amount of hot water as well as the daily profile in which it is consumed impacts significantly on system design. This paper deals with hot water consumption in the commercial and industrial sectors. In the commercial sector, we look at hotels and in the industrial sector at large mining residences. Both of them are served by centralized hot water systems. Measured results from the systems are compared to data obtained from previous publications. A comparison is also made to illustrate the impact that these differences will have on sanitary hot water system design. Simulations are conducted for these systems using a simulation program developed in previous studies. The results clearly show significant differences in the required heating and storage capacity for the new profiles. A twin peak profile obtained from previous studies in the residential sector was used up to now in studies of heating demand and system design in commercial buildings. The results shown here illustrate the sanitary hot water consumption profile differs significantly from the twin peaks profile with a very high morning

  9. Sustainable cold generation by district heat driven absorption refrigerating machinery. High chilling of return flow; Nachhaltige Kaelteerzeugung durch Fernwaermeangetriebene Absorptionskaeltemaschine. Hohe Auskuehlung des Ruecklaufs

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Wolfgang

    2011-06-15

    Cold generation with district heat is still an exception in Germany. The trend towards combined heat and power generation and the increasing demand for reserve power within minutes and at acceptable cost, the economic efficieny of thermal refrigeration processes will be easier to define in the future. The author presents an exemplary building in the German city of Giessen, where a cafe on the 13th level as well as a doctor's surgery are cooled in summer by an absorption refrigerator cooled by district heat.

  10. Status seminar `98: Solar-supported district heating with seasonal heat storage. Status report `98; Status-Seminar `98: Solarunterstuetzte Nahwaermeversorgung - Saisonale Waermespeicherung. Statusbericht `98

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    This status report refers to the BMBF (Federal Ministry for Education, Science, Research and Technology) status seminar: Solar-assisted district heat supply - seasonal heat storage that took place in Neckarsulm on 19th and 20th May. 1998. The report contains the reference papers and the status reports of all projects supported under the Ministry`s SOLARTHERMIE programme that have already been finished or are still running. (orig.) [Deutsch] Der vorliegende Statusbericht wird anlaesslich des BMBF-Statusseminars: Solarunterstuetzte Nahwaermeversorgung - Saisonale Waermespeicherung am 19. und 20. Mai 1998 in Neckarsulm herausgegeben. Der Bericht enthaelt neben den Tagungsbeitraegen auch die Sachstandsberichte aller Projekte, die zu diesem Thema in den letzten Jahren von BMBF in dem Programm SOLARTHERMIE-2000 bereits abgeschlossen wurden oder z.Zt. gefoerdert werden. (orig.)

  11. Oil product sales in 2010 - Results per product and per district

    International Nuclear Information System (INIS)

    Korman, Bernard; Lauverjat, Jean

    2011-11-01

    This document proposes tables of data corresponding to sales of different oil products (super unleaded petrol, Diesel fuel, domestic heating oil, heavy fuels) in metropolitan France in 2011, in the French districts and regions, and in the coastal districts and regions for the maritime sector (fishing activity, ships).

  12. Solar heating and hot water system installed at Southeast of Saline, Unified School District 306, Mentor, Kansas

    Energy Technology Data Exchange (ETDEWEB)

    1979-07-01

    A cooperative agreement was negotiated in April 1978 for the installation of a space and domestic hot water system at Southeast of Saline, Kansas Unified School District 306, Mentor, Kansas. The solar system was installed in a new building and was designed to provide 52 percent of the estimated annual space heating load and 84 percent of the estimated annual potable hot water requirement. The collectors are liquid flat plate. They are ground-mounted and cover a total area of 5125 square feet. The system will provide supplemental heat for the school's closed-loop water-to-air heat pump system and domestic hot water. The storage medium is water inside steel tanks with a capacity of 11,828 gallons for space heating and 1,600 gallons for domestic hot water. This final report, which describes in considerable detail the solar heating facility, contains detailed drawings of the completed system. The facility was declared operational in September 1978, and has functioned successfully since.

  13. Regulation models for district heating. Background report; Denmark; Reguleringsmodeller for fjernvarmen. Baggrundsrapport

    Energy Technology Data Exchange (ETDEWEB)

    2012-02-15

    The background report describes in detail the elements of the analysis: the present regulation, experiences from other countries and sectors, the aim of regulation, and detailed analysis of four regulation models. (LN)

  14. The role, costs and value for money of external consultancies in the health sector: A study of New Zealand's District Health Boards.