WorldWideScience

Sample records for distally mounted ccd

  1. Isolation Mounting for Charge-Coupled Devices

    Science.gov (United States)

    Goss, W. C.; Salomon, P. M.

    1985-01-01

    CCD's suspended by wires under tension. Remote thermoelectric cooling of charge coupled device allows vibration isolating mounting of CCD assembly alone, without having to suspend entire mass and bulk of thermoelectric module. Mounting hardware simple and light. Developed for charge-coupled devices (CCD's) in infrared telescope support adaptable to sensors in variety of environments, e.g., sensors in nuclear reactors, engine exhausts and plasma chambers.

  2. Liner mounting assembly

    Science.gov (United States)

    Halila, Ely E. (Inventor)

    1994-01-01

    A mounting assembly includes an annular supporting flange disposed coaxially about a centerline axis which has a plurality of circumferentially spaced apart supporting holes therethrough. An annular liner is disposed coaxially with the supporting flange and includes a plurality of circumferentially spaced apart mounting holes aligned with respective ones of the supporting holes. Each of a plurality of mounting pins includes a proximal end fixedly joined to the supporting flange through a respective one of the supporting holes, and a distal end disposed through a respective one of the liner mounting holes for supporting the liner to the supporting flange while unrestrained differential thermal movement of the liner relative to the supporting flange.

  3. CCD camera eases the control of a soda recovery boiler; CCD-kamera helpottaa soodakattilan valvontaa

    Energy Technology Data Exchange (ETDEWEB)

    Kinnunen, L.

    2001-07-01

    Fortum Technology has developed a CCD firebox camera, based on semiconductor technology, enduring hard conditions of soda recovery boiler longer than traditional cameras. The firebox camera air- cooled and the same air is pressed over the main lens so it remains clean despite of the alkaline liquor splashing around in the boiler. The image of the boiler is transferred through the main lens, image transfer lens and a special filter, mounted inside the camera tube, into the CCD camera. The first CCD camera system has been in use since 1999 in Sunila pulp mill in Kotka, owned by Myllykoski Oy and Enso Oyj. The mill has two medium-sized soda recovery boilers. The amount of black liquor, formed daily, is about 2000 tons DS, which is more than enough for the heat generation. Even electric power generation exceeds sometimes the demand, so the surplus power can be sold out. Black liquor is sprayed inside the soda recovery boiler with high pressure. The liquor form droplets in the boiler, the temperature of which is over 1000 deg C. A full-hot pile is formed at the bottom of the boiler after burning. The size and shape of the pile effect on the efficiency and the emissions of the boiler. The camera has operated well.

  4. Comparative proteomic analysis of kidney distal convoluted tubule and cortical collecting duct cells following long-term hormonal stimulation

    DEFF Research Database (Denmark)

    Wu, Qi; Moller, Hanne; Rosenbaek, Lena Lindtoft

    2017-01-01

    The distal convoluted tubule (DCT) and the cortical collecting ducts (CCD) are portions of renal tubule that are partly responsible for maintaining the systemic concentrations of potassium, sodium, calcium and magnesium. Despite being structurally similar, DCT and CCD cells have different transpo...... FDR threshold in one cell type plus the unique proteins in this cell type. These 1025 mpkDCT specific proteins and 1211 mpkCCD specific proteins under the three conditions were subjected to further bioinformatics analyses including Panther and DAVID gene ontology analyses, E3 ligase...

  5. A programmable CCD driver circuit for multiphase CCD operation

    International Nuclear Information System (INIS)

    Ewin, A.J.; Reed, K.V.

    1989-01-01

    A programmable CCD driver circuit was designed to drive CCD's in multiphased modes. The purpose of the drive electronics was to operate developmental CCD imaging arrays for NASA's Moderate Resolution Imaging Spectrometer - Tiltable (MODIS-T). Five prototype arrays were designed. Valid's Graphics Editor (GED) was used to design the driver. With this driver design, any of the five arrays can be readout. Designing the driver with GED allowed functional simulation, timing verification, and certain packaging analyses to be done on the design before fabrication. The driver verified its function with the master clock running up to 10 MHz. This suggests a maximum rate of 400 Kpixels/sec. Timing and packaging parameters were verified. the design uses 54 TTL component chips

  6. Advanced CCD camera developments

    Energy Technology Data Exchange (ETDEWEB)

    Condor, A. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    Two charge coupled device (CCD) camera systems are introduced and discussed, describing briefly the hardware involved, and the data obtained in their various applications. The Advanced Development Group Defense Sciences Engineering Division has been actively designing, manufacturing, fielding state-of-the-art CCD camera systems for over a decade. These systems were originally developed for the nuclear test program to record data from underground nuclear tests. Today, new and interesting application for these systems have surfaced and development is continuing in the area of advanced CCD camera systems, with the new CCD camera that will allow experimenters to replace film for x-ray imaging at the JANUS, USP, and NOVA laser facilities.

  7. High-resolution CCD imaging alternatives

    Science.gov (United States)

    Brown, D. L.; Acker, D. E.

    1992-08-01

    High resolution CCD color cameras have recently stimulated the interest of a large number of potential end-users for a wide range of practical applications. Real-time High Definition Television (HDTV) systems are now being used or considered for use in applications ranging from entertainment program origination through digital image storage to medical and scientific research. HDTV generation of electronic images offers significant cost and time-saving advantages over the use of film in such applications. Further in still image systems electronic image capture is faster and more efficient than conventional image scanners. The CCD still camera can capture 3-dimensional objects into the computing environment directly without having to shoot a picture on film develop it and then scan the image into a computer. 2. EXTENDING CCD TECHNOLOGY BEYOND BROADCAST Most standard production CCD sensor chips are made for broadcast-compatible systems. One popular CCD and the basis for this discussion offers arrays of roughly 750 x 580 picture elements (pixels) or a total array of approximately 435 pixels (see Fig. 1). FOR. A has developed a technique to increase the number of available pixels for a given image compared to that produced by the standard CCD itself. Using an inter-lined CCD with an overall spatial structure several times larger than the photo-sensitive sensor areas each of the CCD sensors is shifted in two dimensions in order to fill in spatial gaps between adjacent sensors.

  8. VXD3: The SLD vertex detector upgrade based on a 307 Mpixel CCD system

    International Nuclear Information System (INIS)

    1995-07-01

    The SLD Collaboration is building a new CCD vertex detector (VXD3) comprising 96 3.2 Mpixel CCDs of 13 cm 2 each for a total of 307 million pixels. This system is an upgrade of the Pioneering CCD vertex detector VXD2 which has operated in SLD since 1992. The CCDs of VXD3 are mounted on beryllium ladders in three cylinders, providing three space point measurements along each track of about 5 microns resolution in all three coordinates. The design and construction of VXD3 builds on three years of successful performance of VXD2. Significant improvements are achieved with VXD3 in impact parameters resolution (about a factor of two) and acceptance (∼20%) through optimized geometry and reduced material. New readout electronics have been developed for this system. This new vertex detector will be installed in late 1995 for the future runs of SLD

  9. The OmegaCAM 16K x 16K CCD detector system for the ESO VLT Survey Telescope (VST)

    Science.gov (United States)

    Iwert, Olaf; Baade, D.; Balestra, A.; Baruffolo, A.; Bortolussi, A.; Christen, F.; Cumani, C.; Deiries, S.; Downing, M.; Geimer, C.; Hess, G.; Hess, J.; Kuijken, K.; Lizon, J.; Muschielok, B.; Nicklas, H.; Reiss, R.; Reyes, J.; Silber, A.; Thillerup, J.; Valentijn, E.

    2006-06-01

    A 16K x 16K, 1 degree x 1 degree field, detector system was developed by ESO for the OmegaCAM instrument for use on the purpose built ESO VLT Survey Telescope (VST). The focal plane consists of an 8 x 4 mosaic of 2K x 4K 15um pixel e2v CCDs and four 2K x 4K CCDs on the periphery for the opto-mechanical control of the telescope. The VST is a single instrument telescope. This placed stringent reliability requirements on the OmegaCAM detector system such as 10 years lifetime and maximum downtime of 1.5 %. Mounting at Cassegrain focus required a highly autonomous self-contained cooling system that could deliver 65 W of cooling power. Interface space for the detector head was severely limited by the way the instrument encloses the CCD cryostat. The detector system features several novel ideas tailored to meet these requirements and described in this paper: Key design drivers of the detector head were the easily separable but precisely aligned connections to the optical field flattener on the top and the cooling system at the bottom. Material selection, surface treatment, specialized coatings and in-situ plasma cleaning were crucial to prevent contamination of the detectors. Inside the cryostat, cryogenic and electrical connections were disentangled to keep the configuration modular, integration friendly and the detectors in a safe condition during all mounting steps. A compact unit for logging up to 125 Pt100 temperature sensors and associated thermal control loops was developed (ESO's new housekeeping unit PULPO 2), together with several new modular Pt100 packaging and mounting concepts. The electrical grouping of CCDs based on process parameters and test results is explained. Three ESO standardized FIERA CCD controllers in different configurations are used. Their synchronization mechanism for read-out is discussed in connection with the CCD grouping scheme, the shutter, and the integrated guiding and image analysis facility with four independent 2K x 4K CCDs. An

  10. Enhanced performance CCD output amplifier

    Science.gov (United States)

    Dunham, Mark E.; Morley, David W.

    1996-01-01

    A low-noise FET amplifier is connected to amplify output charge from a che coupled device (CCD). The FET has its gate connected to the CCD in common source configuration for receiving the output charge signal from the CCD and output an intermediate signal at a drain of the FET. An intermediate amplifier is connected to the drain of the FET for receiving the intermediate signal and outputting a low-noise signal functionally related to the output charge signal from the CCD. The amplifier is preferably connected as a virtual ground to the FET drain. The inherent shunt capacitance of the FET is selected to be at least equal to the sum of the remaining capacitances.

  11. Crystallization of the C-terminal domain of the addiction antidote CcdA in complex with its toxin CcdB

    International Nuclear Information System (INIS)

    Buts, Lieven; De Jonge, Natalie; Loris, Remy; Wyns, Lode; Dao-Thi, Minh-Hoa

    2005-01-01

    The CcdA C-terminal domain was crystallized in complex with CcdB in two crystal forms that diffract to beyond 2.0 Å resolution. CcdA and CcdB are the antidote and toxin of the ccd addiction module of Escherichia coli plasmid F. The CcdA C-terminal domain (CcdA C36 ; 36 amino acids) was crystallized in complex with CcdB (dimer of 2 × 101 amino acids) in three different crystal forms, two of which diffract to high resolution. Form II belongs to space group P2 1 2 1 2 1 , with unit-cell parameters a = 37.6, b = 60.5, c = 83.8 Å and diffracts to 1.8 Å resolution. Form III belongs to space group P2 1 , with unit-cell parameters a = 41.0, b = 37.9, c = 69.6 Å, β = 96.9°, and diffracts to 1.9 Å resolution

  12. Transmission electron microscope CCD camera

    Science.gov (United States)

    Downing, Kenneth H.

    1999-01-01

    In order to improve the performance of a CCD camera on a high voltage electron microscope, an electron decelerator is inserted between the microscope column and the CCD. This arrangement optimizes the interaction of the electron beam with the scintillator of the CCD camera while retaining optimization of the microscope optics and of the interaction of the beam with the specimen. Changing the electron beam energy between the specimen and camera allows both to be optimized.

  13. CCD research. [design, fabrication, and applications

    Science.gov (United States)

    Gassaway, J. D.

    1976-01-01

    The fundamental problems encountered in designing, fabricating, and applying CCD's are reviewed. Investigations are described and results and conclusions are given for the following: (1) the development of design analyses employing computer aided techniques and their application to the design of a grapped structure; (2) the role of CCD's in applications to electronic functions, in particular, signal processing; (3) extending the CCD to silicon films on sapphire (SOS); and (4) all aluminum transfer structure with low noise input-output circuits. Related work on CCD imaging devices is summarized.

  14. Measurement of charge of heavy ions in emulsion using a CCD camera

    CERN Document Server

    Kudzia, D; Dabrowska, A; Deines-Jones, P; Holynski, R; Olszewski, A; Nilsen, B S; Sen-Gupta, K; Szarska, M; Trzupek, A; Waddington, C J; Wefel, J P; Wilczynska, B; Wilczynski, H; Wolter, W; Wosiek, B; Wozniak, K

    1999-01-01

    A system has been developed for semi-automated determination of the charges of heavy ions recorded in nuclear emulsions. The profiles of various heavy ion tracks in emulsion, both accelerator beam ions and fragments of heavy projectiles, were obtained with a CCD camera mounted on a microscope. The dependence of track profiles on illumination, emulsion grain size and density, background in emulsion, and track geometry was analyzed. Charges of the fragments of heavy projectiles were estimated independently by the delta ray counting method. A calibration of both width and height of track profiles against ion charges was made with ions of known charges ranging from helium to gold nuclei. (author)

  15. A patient specific finite element simulation of intramedullary nailing to predict the displacement of the distal locking hole.

    Science.gov (United States)

    Mortazavi, Javad; Farahmand, Farzam; Behzadipour, Saeed; Yeganeh, Ali; Aghighi, Mohammad

    2018-05-01

    Distal locking is a challenging subtask of intramedullary nailing fracture fixation due to the nail deformation that makes the proximally mounted targeting systems ineffective. A patient specific finite element model was developed, based on the QCT data of a cadaveric femur, to predict the position of the distal hole of the nail postoperatively. The mechanical interactions of femur and nail (of two sizes) during nail insertion was simulated using ABAQUS in two steps of dynamic pushing and static equilibrium, for the intact and distally fractured bone. Experiments were also performed on the same specimen to validate the simulation results. A good agreement was found between the model predictions and the experimental observations. There was a three-point contact pattern between the nail and medullary canal, only on the proximal fragment of the fractured bone. The nail deflection was much larger in the sagittal plane and increased for the larger diameter nail, as well as for more distally fractured or intact femur. The altered position of the distal hole was predicted by the model with an acceptable error (mean: 0.95; max: 1.5 mm, in different tests) to be used as the compensatory information for fine tuning of proximally mounted targeting systems. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. CCD and IR array controllers

    Science.gov (United States)

    Leach, Robert W.; Low, Frank J.

    2000-08-01

    A family of controllers has bene developed that is powerful and flexible enough to operate a wide range of CCD and IR focal plane arrays in a variety of ground-based applications. These include fast readout of small CCD and IR arrays for adaptive optics applications, slow readout of large CCD and IR mosaics, and single CCD and IR array operation at low background/low noise regimes as well as high background/high speed regimes. The CCD and IR controllers have a common digital core based on user- programmable digital signal processors that are used to generate the array clocking and signal processing signals customized for each application. A fiber optic link passes image data and commands to VME or PCI interface boards resident in a host computer to the controller. CCD signal processing is done with a dual slope integrator operating at speeds of up to one Megapixel per second per channel. Signal processing of IR arrays is done either with a dual channel video processor or a four channel video processor that has built-in image memory and a coadder to 32-bit precision for operating high background arrays. Recent developments underway include the implementation of a fast fiber optic data link operating at a speed of 12.5 Megapixels per second for fast image transfer from the controller to the host computer, and supporting image acquisition software and device drivers for the PCI interface board for the Sun Solaris, Linux and Windows 2000 operating systems.

  17. Enzymatic study on AtCCD4 and AtCCD7 and their potential to form acyclic regulatory metabolites

    KAUST Repository

    Bruno, Mark

    2016-09-29

    The Arabidopsis carotenoid cleavage dioxygenase 4 (AtCCD4) is a negative regulator of the carotenoid content of seeds and has recently been suggested as a candidate for the generation of retrograde signals that are thought to derive from the cleavage of poly-cis-configured carotene desaturation intermediates. In this work, we investigated the activity of AtCCD4 in vitro and used dynamic modeling to determine its substrate preference. Our results document strict regional specificity for cleavage at the C9–C10 double bond in carotenoids and apocarotenoids, with preference for carotenoid substrates and an obstructing effect on hydroxyl functions, and demonstrate the specificity for all-trans-configured carotenes and xanthophylls. AtCCD4 cleaved substrates with at least one ionone ring and did not convert acyclic carotene desaturation intermediates, independent of their isomeric states. These results do not support a direct involvement of AtCCD4 in generating the supposed regulatory metabolites. In contrast, the strigolactone biosynthetic enzyme AtCCD7 converted 9-cis-configured acyclic carotenes, such as 9-cis-ζ-carotene, 9\\'-cis-neurosporene, and 9-cis-lycopene, yielding 9-cis-configured products and indicating that AtCCD7, rather than AtCCD4, is the candidate for forming acyclic retrograde signals.

  18. Enzymatic study on AtCCD4 and AtCCD7 and their potential to form acyclic regulatory metabolites

    KAUST Repository

    Bruno, Mark; Koschmieder, Julian; Wuest, Florian; Schaub, Patrick; Fehling-Kaschek, Mirjam; Timmer, Jens; Beyer, Peter; Al-Babili, Salim

    2016-01-01

    The Arabidopsis carotenoid cleavage dioxygenase 4 (AtCCD4) is a negative regulator of the carotenoid content of seeds and has recently been suggested as a candidate for the generation of retrograde signals that are thought to derive from the cleavage of poly-cis-configured carotene desaturation intermediates. In this work, we investigated the activity of AtCCD4 in vitro and used dynamic modeling to determine its substrate preference. Our results document strict regional specificity for cleavage at the C9–C10 double bond in carotenoids and apocarotenoids, with preference for carotenoid substrates and an obstructing effect on hydroxyl functions, and demonstrate the specificity for all-trans-configured carotenes and xanthophylls. AtCCD4 cleaved substrates with at least one ionone ring and did not convert acyclic carotene desaturation intermediates, independent of their isomeric states. These results do not support a direct involvement of AtCCD4 in generating the supposed regulatory metabolites. In contrast, the strigolactone biosynthetic enzyme AtCCD7 converted 9-cis-configured acyclic carotenes, such as 9-cis-ζ-carotene, 9'-cis-neurosporene, and 9-cis-lycopene, yielding 9-cis-configured products and indicating that AtCCD7, rather than AtCCD4, is the candidate for forming acyclic retrograde signals.

  19. Enzymatic study on AtCCD4 and AtCCD7 and their potential to form acyclic regulatory metabolites

    Science.gov (United States)

    Bruno, Mark; Koschmieder, Julian; Wuest, Florian; Schaub, Patrick; Fehling-Kaschek, Mirjam; Timmer, Jens; Beyer, Peter; Al-Babili, Salim

    2016-01-01

    The Arabidopsis carotenoid cleavage dioxygenase 4 (AtCCD4) is a negative regulator of the carotenoid content of seeds and has recently been suggested as a candidate for the generation of retrograde signals that are thought to derive from the cleavage of poly-cis-configured carotene desaturation intermediates. In this work, we investigated the activity of AtCCD4 in vitro and used dynamic modeling to determine its substrate preference. Our results document strict regional specificity for cleavage at the C9–C10 double bond in carotenoids and apocarotenoids, with preference for carotenoid substrates and an obstructing effect on hydroxyl functions, and demonstrate the specificity for all-trans-configured carotenes and xanthophylls. AtCCD4 cleaved substrates with at least one ionone ring and did not convert acyclic carotene desaturation intermediates, independent of their isomeric states. These results do not support a direct involvement of AtCCD4 in generating the supposed regulatory metabolites. In contrast, the strigolactone biosynthetic enzyme AtCCD7 converted 9-cis-configured acyclic carotenes, such as 9-cis-ζ-carotene, 9'-cis-neurosporene, and 9-cis-lycopene, yielding 9-cis-configured products and indicating that AtCCD7, rather than AtCCD4, is the candidate for forming acyclic retrograde signals. PMID:27811075

  20. Calibration of the photometric method of heavy ion charge measurements in emulsion using a CCD camera

    International Nuclear Information System (INIS)

    Kudzia, D.; Wilczynska, B.; Wilczynski, H.

    2002-01-01

    A previously developed method of heavy ion charge measurements in emulsion has been significantly improved. The charge measurements are based on analysis of photometric profiles of the particle tracks in emulsion. These profiles are obtained using a CCD camera mounted on an optical microscope. So far, the manual charge determination by delta ray counting had to be used for calibration of the photometric method. In this paper a complete procedure for calibration of the photometric method is shown, without resorting to the manual method

  1. Charge diffusion in CCD X-ray detectors

    International Nuclear Information System (INIS)

    Pavlov, George G.; Nousek, John A.

    1999-01-01

    Critical to the detection of X-rays by CCDs, is the detailed process of charge diffusion and drift within the device. We reexamine the prescriptions currently used in the modeling of X-ray CCD detectors to provide analytic expressions for the charge distribution over the CCD pixels which are suitable for use in numerical simulations of CCD response. Our treatment results in models which predict charge distributions which are more centrally peaked and have flatter wings than the Gaussian shapes predicted by previous work and adopted in current CCD modeling codes

  2. Fully depleted back-illuminated p-channel CCD development

    Energy Technology Data Exchange (ETDEWEB)

    Bebek, Chris J.; Bercovitz, John H.; Groom, Donald E.; Holland, Stephen E.; Kadel, Richard W.; Karcher, Armin; Kolbe, William F.; Oluseyi, Hakeem M.; Palaio, Nicholas P.; Prasad, Val; Turko, Bojan T.; Wang, Guobin

    2003-07-08

    An overview of CCD development efforts at Lawrence Berkeley National Laboratory is presented. Operation of fully-depleted, back-illuminated CCD's fabricated on high resistivity silicon is described, along with results on the use of such CCD's at ground-based observatories. Radiation damage and point-spread function measurements are described, as well as discussion of CCD fabrication technologies.

  3. CCD's at TPC

    International Nuclear Information System (INIS)

    Zeller, M.E.

    1977-01-01

    The CCD, Charge Coupled Device, is an analog shift register for which application to the readout of particle detectors has recently been realized. These devices can be used to detect optical information directly, providing an automated readout for streamer or other optical chambers, or as a single input shift register, acting in this instance as a delay line for analog information. A description is given of the latter mode of operation and its utility as a readout method for drift chambers. Most of the information contained herein has been obtained from tests performed in connection with PEP TPC project, PEP-4. That detector will employ approximately 10 4 CCD's making it a reasonable testing ground for ISABELLE size detectors

  4. Purification and crystallization of Vibrio fischeri CcdB and its complexes with fragments of gyrase and CcdA

    International Nuclear Information System (INIS)

    De Jonge, Natalie; Buts, Lieven; Vangelooven, Joris; Mine, Natacha; Van Melderen, Laurence; Wyns, Lode; Loris, Remy

    2007-01-01

    A CcdB homologue from V. fischeri was overexpressed in E. coli and purified. The free protein was crystallized, as were its complexes with fragments of E. coli and V. fischeri gyrase and with the F-plasmid CcdA C-terminal domain. The ccd toxin–antitoxin module from the Escherichia coli F plasmid has a homologue on the Vibrio fischeri integron. The homologue of the toxin (CcdB Vfi ) was crystallized in two different crystal forms. The first form belongs to space group I23 or I2 1 3, with unit-cell parameter a = 84.5 Å, and diffracts to 1.5 Å resolution. The second crystal form belongs to space group C2, with unit-cell parameters a = 58.5, b = 43.6, c = 37.5 Å, β = 110.0°, and diffracts to 1.7 Å resolution. The complex of CcdB Vfi with the GyrA14 Vfi fragment of V. fischeri gyrase crystallizes in space group P2 1 2 1 2 1 , with unit-cell parameters a = 53.5, b = 94.6, c = 58.1 Å, and diffracts to 2.2 Å resolution. The corresponding mixed complex with E. coli GyrA14 Ec crystallizes in space group C2, with unit-cell parameters a = 130.1, b = 90.8, c = 58.1 Å, β = 102.6°, and diffracts to 1.95 Å. Finally, a complex between CcdB Vfi and part of the F-plasmid antitoxin CcdA F crystallizes in space group P2 1 2 1 2 1 , with unit-cell parameters a = 46.9, b = 62.6, c = 82.0 Å, and diffracts to 1.9 Å resolution

  5. Follow-up study of children with cerebral coordination disturbance (CCD, Vojta).

    Science.gov (United States)

    Imamura, S; Sakuma, K; Takahashi, T

    1983-01-01

    713 children (from newborn to 12-month-old) with delayed motor development were carefully examined and classified into normal, very light cerebral coordination disturbance (CCD, Vojta), light CCD, moderate CCD, severe CCD, suspected cerebral palsy (CP) and other diseases at their first visit, and were followed up carefully. Finally, 89.0% of very light CCD, 71.4% of light CCD, 56.0% of moderate CCD and 30.0% of severe CCD developed into normal. 59.5% of moderate CCD and 45.5% of severe CCD among children who were given Vojta's physiotherapy developed into normal. The classification of cases with delayed motor development into very light, light, moderate and severe CCD based on the extent of abnormality in their postural reflexes is useful and well correlated with their prognosis. Treatment by Vojta's method seems to be efficient and helpful for young children with delayed motor development.

  6. Purification and crystallization of Vibrio fischeri CcdB and its complexes with fragments of gyrase and CcdA

    Energy Technology Data Exchange (ETDEWEB)

    De Jonge, Natalie, E-mail: ndejonge@vub.ac.be; Buts, Lieven; Vangelooven, Joris [Department of Molecular and Cellular Interactions, VIB, Pleinlaan 2, 1050 Brussels (Belgium); Laboratorium voor Ultrastructuur, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels (Belgium); Mine, Natacha; Van Melderen, Laurence [Laboratoire de Génétique des Procaryotes, Institut de Biologie et de Médecine, Université Libre de Bruxelles, Gosselies (Belgium); Wyns, Lode; Loris, Remy [Department of Molecular and Cellular Interactions, VIB, Pleinlaan 2, 1050 Brussels (Belgium); Laboratorium voor Ultrastructuur, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels (Belgium)

    2007-04-01

    A CcdB homologue from V. fischeri was overexpressed in E. coli and purified. The free protein was crystallized, as were its complexes with fragments of E. coli and V. fischeri gyrase and with the F-plasmid CcdA C-terminal domain. The ccd toxin–antitoxin module from the Escherichia coli F plasmid has a homologue on the Vibrio fischeri integron. The homologue of the toxin (CcdB{sub Vfi}) was crystallized in two different crystal forms. The first form belongs to space group I23 or I2{sub 1}3, with unit-cell parameter a = 84.5 Å, and diffracts to 1.5 Å resolution. The second crystal form belongs to space group C2, with unit-cell parameters a = 58.5, b = 43.6, c = 37.5 Å, β = 110.0°, and diffracts to 1.7 Å resolution. The complex of CcdB{sub Vfi} with the GyrA14{sub Vfi} fragment of V. fischeri gyrase crystallizes in space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 53.5, b = 94.6, c = 58.1 Å, and diffracts to 2.2 Å resolution. The corresponding mixed complex with E. coli GyrA14{sub Ec} crystallizes in space group C2, with unit-cell parameters a = 130.1, b = 90.8, c = 58.1 Å, β = 102.6°, and diffracts to 1.95 Å. Finally, a complex between CcdB{sub Vfi} and part of the F-plasmid antitoxin CcdA{sub F} crystallizes in space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 46.9, b = 62.6, c = 82.0 Å, and diffracts to 1.9 Å resolution.

  7. Noise characteristics of neutron images obtained by cooled CCD device

    International Nuclear Information System (INIS)

    Taniguchi, Ryoichi; Sasaki, Ryoya; Okuda, Shuichi; Okamoto, Ken-Ichi; Ogawa, Yoshihiro; Tsujimoto, Tadashi

    2009-01-01

    The noise characteristics of a cooled CCD device induced by neutron and gamma ray irradiation have been investigated. In the cooled CCD images, characteristic white spot noises (CCD noise) frequently appeared, which have a shape like a pixel in most cases and their brightness is extremely high compared with that of the image pattern. They could be divided into the two groups, fixed pattern noise (FPN) and random noise. The former always appeared in the same position in the image and the latter appeared at any position. In the background image, nearly all of the CCD noises were found to be the FPN, while many of them were the random noise during the irradiation. The random CCD noises increased with irradiation and decreased soon after the irradiation. In the case of large irradiation, a part of the CCD noise remained as the FPN. These facts suggest that the CCD noise is a phenomenon strongly relating to radiation damage of the CCD device.

  8. Digital Data for Volcano Hazards in the Mount Jefferson Region, Oregon

    Science.gov (United States)

    Schilling, S.P.; Doelger, S.; Walder, J.S.; Gardner, C.A.; Conrey, R.M.; Fisher, B.J.

    2008-01-01

    Mount Jefferson has erupted repeatedly for hundreds of thousands of years, with its last eruptive episode during the last major glaciation which culminated about 15,000 years ago. Geologic evidence shows that Mount Jefferson is capable of large explosive eruptions. The largest such eruption occurred between 35,000 and 100,000 years ago. If Mount Jefferson erupts again, areas close to the eruptive vent will be severely affected, and even areas tens of kilometers (tens of miles) downstream along river valleys or hundreds of kilometers (hundreds of miles) downwind may be at risk. Numerous small volcanoes occupy the area between Mount Jefferson and Mount Hood to the north, and between Mount Jefferson and the Three Sisters region to the south. These small volcanoes tend not to pose the far-reaching hazards associated with Mount Jefferson, but are nonetheless locally important. A concern at Mount Jefferson, but not at the smaller volcanoes, is the possibility that small-to-moderate sized landslides could occur even during periods of no volcanic activity. Such landslides may transform as they move into lahars (watery flows of rock, mud, and debris) that can inundate areas far downstream. The geographic information system (GIS) volcano hazard data layer used to produce the Mount Jefferson volcano hazard map in USGS Open-File Report 99-24 (Walder and others, 1999) is included in this data set. Both proximal and distal hazard zones were delineated by scientists at the Cascades Volcano Observatory and depict various volcano hazard areas around the mountain.

  9. Esophagojejunal Anastomosis Fistula, Distal Esophageal Stenosis, and Metalic Stent Migration after Total Gastrectomy

    Directory of Open Access Journals (Sweden)

    Nadim Al Hajjar

    2015-01-01

    Full Text Available Esophagojejunal anastomosis fistula is the main complication after a total gastrectomy. To avoid a complex procedure on friable inflamed perianastomotic tissues, a coated self-expandable stent is mounted at the site of the anastomotic leak. A complication of stenting procedure is that it might lead to distal esophageal stenosis. However, another frequently encountered complication of stenting is stent migration, which is treated nonsurgically. When the migrated stent creates life threatening complications, surgical removal is indicated. We present a case of a 67-year-old male patient who was treated at our facility for a gastric adenocarcinoma which developed, postoperatively, an esophagojejunostomy fistula, a distal esophageal stenosis, and a metallic coated self-expandable stent migration. To our knowledge, this is the first reported case of an esophagojejunostomy fistula combined with a distal esophageal stenosis as well as with a metallic coated self-expandable stent migration.

  10. CCD Astrophotography High-Quality Imaging from the Suburbs

    CERN Document Server

    Stuart, Adam

    2006-01-01

    This is a reference book for amateur astronomers who have become interested in CCD imaging. Those glorious astronomical images found in astronomy magazines might seem out of reach to newcomers to CCD imaging, but this is not the case. Great pictures are attainable with modest equipment. Adam Stuart’s many beautiful images, reproduced in this book, attest to the quality of – initially – a beginner’s efforts. Chilled-chip astronomical CCD-cameras and software are also wonderful tools for cutting through seemingly impenetrable light-pollution. CCD Astrophotography from the Suburbs describes one man’s successful approach to the problem of getting high-quality astronomical images under some of the most light-polluted conditions. Here is a complete and thoroughly tested program that will help every CCD-beginner to work towards digital imaging of the highest quality. It is equally useful to astronomers who have perfect observing conditions, as to those who have to observe from light-polluted city skies.

  11. DISTAL MYOPATHIES

    Science.gov (United States)

    Dimachkie, Mazen M.; Barohn, Richard J.

    2014-01-01

    Over a century ago, Gowers described two young patients in whom distal muscles weakness involved the hand, foot, sternocleidomastoid, and facial muscles in the other case the shoulder and distal leg musculature. Soon after, , similar distal myopathy cases were reported whereby the absence of sensory symptoms and of pathologic changes in the peripheral nerves and spinal cord at postmortem examination allowed differentiation from Charcot-Marie-Tooth disease. In 1951, Welander described autosomal dominant (AD) distal arm myopathy in a large Scandanavian cohort. Since then the number of well-characterized distal myopathies has continued to grow such that the distal myopathies have formed a clinically and genetically heterogeneous group of disorders. Affected kindred commonly manifest weakness that is limited to foot and toe muscles even in advanced stages of the disease, with variable mild proximal leg, distal arm, neck and laryngeal muscle involvement in selected individuals. An interesting consequence of the molecular characterization of the distal myopathies has been the recognition that mutation in a single gene can lead to more than one clinical disorder. For example, Myoshi myopathy (MM) and limb girdle muscular dystrophy (LGMD) type 2B are allelic disorders due to defects in the gene that encodes dysferlin. The six well described distal myopathy syndromes are shown in Table 1. Table 2 lists advances in our understanding of the myofibrillar myopathy group and Table 3 includes more recently delineated and less common distal myopathies. In the same manner, the first section of this review pertains to the more traditional six distal myopathies followed by discussion of the myofibrillar myopathies. In the third section, we review other clinically and genetically distinctive distal myopathy syndromes usually based upon single or smaller family cohorts. The fourth section considers other neuromuscular disorders that are important to recognize as they display prominent

  12. Custom CCD for adaptive optics applications

    Science.gov (United States)

    Downing, Mark; Arsenault, Robin; Baade, Dietrich; Balard, Philippe; Bell, Ray; Burt, David; Denney, Sandy; Feautrier, Philippe; Fusco, Thierry; Gach, Jean-Luc; Diaz Garcia, José Javier; Guillaume, Christian; Hubin, Norbert; Jorden, Paul; Kasper, Markus; Meyer, Manfred; Pool, Peter; Reyes, Javier; Skegg, Michael; Stadler, Eric; Suske, Wolfgang; Wheeler, Patrick

    2006-06-01

    ESO and JRA2 OPTICON have funded e2v technologies to develop a compact packaged Peltier cooled 24 μm square 240x240 pixels split frame transfer 8-output back-illuminated L3Vision CCD3, L3Vision CCD for Adaptive Optic Wave Front Sensor (AO WFS) applications. The device is designed to achieve sub-electron read noise at frame rates from 25 Hz to 1,500 Hz and dark current lower than 0.01 e-/pixel/frame. The development has many unique features. To obtain high frame rates, multi-output EMCCD gain registers and metal buttressing of row clock lines are used. The baseline device is built in standard silicon. In addition, a split wafer run has enabled two speculative variants to be built; deep depletion silicon devices to improve red response and devices with an electronic shutter to extend use to Rayleigh and Pulsed Laser Guide Star applications. These are all firsts for L3Vision CCDs. The designs of the CCD and Peltier package have passed their reviews and fabrication has begun. This paper will describe the progress to date, the requirements and the design of the CCD and compact Peltier package, technology trade-offs, schedule and proposed test plan. High readout speed, low noise and compactness (requirement to fit in confined spaces) provide special challenges to ESO's AO variant of its NGC, New General detector Controller to drive this CCD. This paper will describe progress made on the design of the controller to meet these special needs.

  13. THE ACCURACY OF Hβ CCD PHOTOMETRY

    Directory of Open Access Journals (Sweden)

    C. Kim

    1994-12-01

    Full Text Available We have undertaken CCD observations of field standard stars with Hβ photometric system to investigate the reliability of Hβ CCD photometry. Flat fielding with dome flat and sky flat for Hβw and Hβn filter was compared with that of B filter in UBV system and, from these, we have not found any difference. It was confirmed that there is a good linear relationship between our Hβ values observed with 2.3m reflector and standard values. However, Hβ values observed with 60cm reflector at Sobaeksan Astronomy Observatory showed very poor relationship. To investigate the accuracy of Hβ CCD photometry for fainter objects, open cluster NGC2437 was observed and reduced with DoPHOT, and the results were compared with those for photoelectric photometry of Stetson (1981.

  14. Correlation and image compression for limited-bandwidth CCD.

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Douglas G.

    2005-07-01

    As radars move to Unmanned Aerial Vehicles with limited-bandwidth data downlinks, the amount of data stored and transmitted with each image becomes more significant. This document gives the results of a study to determine the effect of lossy compression in the image magnitude and phase on Coherent Change Detection (CCD). We examine 44 lossy compression types, plus lossless zlib compression, and test each compression method with over 600 CCD image pairs. We also derive theoretical predictions for the correlation for most of these compression schemes, which compare favorably with the experimental results. We recommend image transmission formats for limited-bandwidth programs having various requirements for CCD, including programs which cannot allow performance degradation and those which have stricter bandwidth requirements at the expense of CCD performance.

  15. Typical effects of laser dazzling CCD camera

    Science.gov (United States)

    Zhang, Zhen; Zhang, Jianmin; Shao, Bibo; Cheng, Deyan; Ye, Xisheng; Feng, Guobin

    2015-05-01

    In this article, an overview of laser dazzling effect to buried channel CCD camera is given. The CCDs are sorted into staring and scanning types. The former includes the frame transfer and interline transfer types. The latter includes linear and time delay integration types. All CCDs must perform four primary tasks in generating an image, which are called charge generation, charge collection, charge transfer and charge measurement. In camera, the lenses are needed to input the optical signal to the CCD sensors, in which the techniques for erasing stray light are used. And the electron circuits are needed to process the output signal of CCD, in which many electronic techniques are used. The dazzling effects are the conjunct result of light distribution distortion and charge distribution distortion, which respectively derive from the lens and the sensor. Strictly speaking, in lens, the light distribution is not distorted. In general, the lens are so well designed and fabricated that its stray light can be neglected. But the laser is of much enough intensity to make its stray light obvious. In CCD image sensors, laser can induce a so large electrons generation. Charges transfer inefficiency and charges blooming will cause the distortion of the charge distribution. Commonly, the largest signal outputted from CCD sensor is restricted by capability of the collection well of CCD, and can't go beyond the dynamic range for the subsequent electron circuits maintaining normal work. So the signal is not distorted in the post-processing circuits. But some techniques in the circuit can make some dazzling effects present different phenomenon in final image.

  16. A new apparatus for track-analysis in nuclear track emulsion based on a CCD-camera device

    International Nuclear Information System (INIS)

    Ganssauge, E.

    1993-01-01

    A CCD camera-based, image-analyzing system for automatic evaluation of nuclear track emulsion chambers is presented. The stage of a normal microscope moves using three remote controlled stepping motors with a step size of 0.25 μm. A CCD-camera is mounted on tope of the microscope in order to register the nuclear emulsion. The camera has a resolution capable of differentiating single emulsion-grains (0.6 μm). The camera picture is transformed from analogue to digital signals and stored by a frame grabber. Some background-picture elements can be eliminated by applying cuts on grey levels. The central computer processes the picture, correlates the single picture points, the coordinates and the grey-levels, such that in the end one has a unique assignment of each picture point to an address on the hard disk for a given plate. After repetition of this procedure for several plates by means of an appropriate software (for instance our vertex program [1]). the coordinates of the points are combined to tracks, and a variety of distributions like pseudorapidity-distributions can be calculated and presented on the terminal. (author)

  17. Contribution of the Chromosomal ccdAB Operon to Bacterial Drug Tolerance.

    Science.gov (United States)

    Gupta, Kritika; Tripathi, Arti; Sahu, Alishan; Varadarajan, Raghavan

    2017-10-01

    One of the first identified and best-studied toxin-antitoxin (TA) systems in Escherichia coli is the F-plasmid-based CcdAB system. This system is involved in plasmid maintenance through postsegregational killing. More recently, ccdAB homologs have been found on the chromosome, including in pathogenic strains of E. coli and other bacteria. However, the functional role of chromosomal ccdAB genes, if any, has remained unclear. We show that both the native ccd operon of the E. coli O157 strain ( ccd O157 ) and the ccd operon from the F plasmid ( ccd F ), when inserted on the E. coli chromosome, lead to protection from cell death under multiple antibiotic stress conditions through formation of persisters, with the O157 operon showing higher protection. While the plasmid-encoded CcdB toxin is a potent gyrase inhibitor and leads to bacterial cell death even under fully repressed conditions, the chromosomally encoded toxin leads to growth inhibition, except at high expression levels, where some cell death is seen. This was further confirmed by transiently activating the chromosomal ccd operon through overexpression of an active-site inactive mutant of F-plasmid-encoded CcdB. Both the ccd F and ccd O157 operons may share common mechanisms for activation under stress conditions, eventually leading to multidrug-tolerant persister cells. This study clearly demonstrates an important role for chromosomal ccd systems in bacterial persistence. IMPORTANCE A large number of free-living and pathogenic bacteria are known to harbor multiple toxin-antitoxin systems, on plasmids as well as on chromosomes. The F-plasmid CcdAB system has been extensively studied and is known to be involved in plasmid maintenance. However, little is known about the function of its chromosomal counterpart, found in several pathogenic E. coli strains. We show that the native chromosomal ccd operon of the E. coli O157 strain is involved in drug tolerance and confers protection from cell death under multiple

  18. High-Voltage Clock Driver for Photon-Counting CCD Characterization

    Science.gov (United States)

    Baker, Robert

    2013-01-01

    A document discusses the CCD97 from e2v technologies as it is being evaluated at Goddard Space Flight Center's Detector Characterization Laboratory (DCL) for possible use in ultra-low background noise space astronomy applications, such as Terrestrial Planet Finder Coronagraph (TPF-C). The CCD97 includes a photoncounting mode where the equivalent output noise is less than one electron. Use of this mode requires a clock signal at a voltage level greater than the level achievable by the existing CCD (charge-coupled-device) electronics. A high-voltage waveform generator has been developed in code 660/601 to support the CCD97 evaluation. The unit generates required clock waveforms at voltage levels from -20 to +50 V. It deals with standard and arbitrary waveforms and supports pixel rates from 50 to 500 kHz. The system is designed to interface with existing Leach CCD electronics.

  19. Accuracy and precision of equine gait event detection during walking with limb and trunk mounted inertial sensors

    DEFF Research Database (Denmark)

    Olsen, Emil; Andersen, Pia Haubro; Pfau, Thilo

    2012-01-01

    The increased variations of temporal gait events when pathology is present are good candidate features for objective diagnostic tests. We hypothesised that the gait events hoof-on/off and stance can be detected accurately and precisely using features from trunk and distal limb-mounted Inertial....... Accuracy (bias) and precision (SD of bias) was calculated to compare force plate and IMU timings for gait events. Data were collected from seven horses. One hundred and twenty three (123) front limb steps were analysed; hoof-on was detected with a bias (SD) of -7 (23) ms, hoof-off with 0.7 (37) ms...... and front limb stance with -0.02 (37) ms. A total of 119 hind limb steps were analysed; hoof-on was found with a bias (SD) of -4 (25) ms, hoof-off with 6 (21) ms and hind limb stance with 0.2 (28) ms. IMUs mounted on the distal limbs and sacrum can detect gait events accurately and precisely....

  20. 15 CFR 740.19 - Consumer Communications Devices (CCD).

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Consumer Communications Devices (CCD... EXCEPTIONS § 740.19 Consumer Communications Devices (CCD). (a) Authorization. This License Exception... controllers designed for chemical processing) designated EAR99; (4) Graphics accelerators and graphics...

  1. CCD image sensor induced error in PIV applications

    Science.gov (United States)

    Legrand, M.; Nogueira, J.; Vargas, A. A.; Ventas, R.; Rodríguez-Hidalgo, M. C.

    2014-06-01

    The readout procedure of charge-coupled device (CCD) cameras is known to generate some image degradation in different scientific imaging fields, especially in astrophysics. In the particular field of particle image velocimetry (PIV), widely extended in the scientific community, the readout procedure of the interline CCD sensor induces a bias in the registered position of particle images. This work proposes simple procedures to predict the magnitude of the associated measurement error. Generally, there are differences in the position bias for the different images of a certain particle at each PIV frame. This leads to a substantial bias error in the PIV velocity measurement (˜0.1 pixels). This is the order of magnitude that other typical PIV errors such as peak-locking may reach. Based on modern CCD technology and architecture, this work offers a description of the readout phenomenon and proposes a modeling for the CCD readout bias error magnitude. This bias, in turn, generates a velocity measurement bias error when there is an illumination difference between two successive PIV exposures. The model predictions match the experiments performed with two 12-bit-depth interline CCD cameras (MegaPlus ES 4.0/E incorporating the Kodak KAI-4000M CCD sensor with 4 megapixels). For different cameras, only two constant values are needed to fit the proposed calibration model and predict the error from the readout procedure. Tests by different researchers using different cameras would allow verification of the model, that can be used to optimize acquisition setups. Simple procedures to obtain these two calibration values are also described.

  2. CCD image sensor induced error in PIV applications

    International Nuclear Information System (INIS)

    Legrand, M; Nogueira, J; Vargas, A A; Ventas, R; Rodríguez-Hidalgo, M C

    2014-01-01

    The readout procedure of charge-coupled device (CCD) cameras is known to generate some image degradation in different scientific imaging fields, especially in astrophysics. In the particular field of particle image velocimetry (PIV), widely extended in the scientific community, the readout procedure of the interline CCD sensor induces a bias in the registered position of particle images. This work proposes simple procedures to predict the magnitude of the associated measurement error. Generally, there are differences in the position bias for the different images of a certain particle at each PIV frame. This leads to a substantial bias error in the PIV velocity measurement (∼0.1 pixels). This is the order of magnitude that other typical PIV errors such as peak-locking may reach. Based on modern CCD technology and architecture, this work offers a description of the readout phenomenon and proposes a modeling for the CCD readout bias error magnitude. This bias, in turn, generates a velocity measurement bias error when there is an illumination difference between two successive PIV exposures. The model predictions match the experiments performed with two 12-bit-depth interline CCD cameras (MegaPlus ES 4.0/E incorporating the Kodak KAI-4000M CCD sensor with 4 megapixels). For different cameras, only two constant values are needed to fit the proposed calibration model and predict the error from the readout procedure. Tests by different researchers using different cameras would allow verification of the model, that can be used to optimize acquisition setups. Simple procedures to obtain these two calibration values are also described. (paper)

  3. Active Pixel Sensors: Are CCD's Dinosaurs?

    Science.gov (United States)

    Fossum, Eric R.

    1993-01-01

    Charge-coupled devices (CCD's) are presently the technology of choice for most imaging applications. In the 23 years since their invention in 1970, they have evolved to a sophisticated level of performance. However, as with all technologies, we can be certain that they will be supplanted someday. In this paper, the Active Pixel Sensor (APS) technology is explored as a possible successor to the CCD. An active pixel is defined as a detector array technology that has at least one active transistor within the pixel unit cell. The APS eliminates the need for nearly perfect charge transfer -- the Achilles' heel of CCDs. This perfect charge transfer makes CCD's radiation 'soft,' difficult to use under low light conditions, difficult to manufacture in large array sizes, difficult to integrate with on-chip electronics, difficult to use at low temperatures, difficult to use at high frame rates, and difficult to manufacture in non-silicon materials that extend wavelength response.

  4. Solution structure and elevator mechanism of the membrane electron transporter CcdA.

    Science.gov (United States)

    Zhou, Yunpeng; Bushweller, John H

    2018-02-01

    Membrane oxidoreductase CcdA plays a central role in supplying reducing equivalents from the bacterial cytoplasm to the envelope. It transports electrons across the membrane using a single pair of cysteines by a mechanism that has not yet been elucidated. Here we report an NMR structure of the Thermus thermophilus CcdA (TtCcdA) in an oxidized and outward-facing state. CcdA consists of two inverted structural repeats of three transmembrane helices (2 × 3-TM). We computationally modeled and experimentally validated an inward-facing state, which suggests that CcdA uses an elevator-type movement to shuttle the reactive cysteines across the membrane. CcdA belongs to the LysE superfamily, and thus its structure may be relevant to other LysE clan transporters. Structure comparisons of CcdA, semiSWEET, Pnu, and major facilitator superfamily (MFS) transporters provide insights into membrane transporter architecture and mechanism.

  5. CCD camera system for use with a streamer chamber

    International Nuclear Information System (INIS)

    Angius, S.A.; Au, R.; Crawley, G.C.; Djalali, C.; Fox, R.; Maier, M.; Ogilvie, C.A.; Molen, A. van der; Westfall, G.D.; Tickle, R.S.

    1988-01-01

    A system based on three charge-coupled-device (CCD) cameras is described here. It has been used to acquire images from a streamer chamber and consists of three identical subsystems, one for each camera. Each subsystem contains an optical lens, CCD camera head, camera controller, an interface between the CCD and a microprocessor, and a link to a minicomputer for data recording and on-line analysis. Image analysis techniques have been developed to enhance the quality of the particle tracks. Some steps have been made to automatically identify tracks and reconstruct the event. (orig.)

  6. CCD-based X-ray detectors for X-ray diffraction studies

    International Nuclear Information System (INIS)

    Ito, K.; Amemiya, Y.

    1999-01-01

    CCD-based X-ray detectors are getting to be used for X-ray diffraction studies especially in the studies where real time (automated) measurements and time-resolved measurements are required. Principles and designs of two typical types of CCD-based detectors are described; one is ths system in which x-ray image intensifiers are coupled to maximize the detective quantum efficiency for time-resolved measurements, and the other is the system in which tapered optical fibers are coupled for the reduction of the image into the CCD, which is optimized for automated measurements for protein crystallography. These CCD-based X-ray detectors have an image distortion and non-uniformity of response to be corrected by software. Correction schemes which we have developed are also described. (author)

  7. Image differencing using masked CCD

    International Nuclear Information System (INIS)

    Rushbrooke, J.G.; Ansorge, R.E.; Webber, C.J. St. J.

    1987-01-01

    A charge coupled device has some of its ''pixels'' masked by a material which is opaque to the radiation to which the device is to be exposed, each masked region being employed as a storage zone into which the charge pattern from the unmasked pixels can be transferred to enable a subsequent charge pattern to be established on further exposure of the unmasked pixels. The components of the resulting video signal corresponding to the respective charge patterns read-out from the CCD are subtracted to produce a video signal corresponding to the difference between the two images which formed the respective charge patterns. Alternate rows of pixels may be masked, or chequer-board pattern masking may be employed. In an X-ray imaging system the CCD is coupled to image intensifying and converting means. (author)

  8. A CCD portrait of Comet P/Tempel 2

    International Nuclear Information System (INIS)

    Jewitt, D.; Luu, J.

    1989-01-01

    The development of activity in Comet P/Tempel 2 is studied from aphelion (R = 4 AU) to perihelion (R = 1.4 AU) using extensive time-series CCD photometry and CCD spectra. The comet undergoes a profound morphological change at R of about 2-2.5 AU, from a bare nucleus at larger distances to an active comet supporting a coma of gas and dust. Cyclic photometric variations with the period T = 8.95 + or - 0.01 hr. are present at all R, and are attributed to the rotation of the nucleus at this period. The nucleus is prolate (axes a:b:c = 1.9:1:1), a property shared with other nuclei studied using CCD photometry. Novel results include a limit on the bulk density of the nucleus, rho above 300 kg/cu m, and a 20-A-resolution CCD spectrum of the nucleus. Spatially and temporally resolved photometry is used to study the effects of nucleus rotation on the coma. The coma does not share the dramatic photometric variations shown by the nucleus. It possesses a steep surface-brightness distribution, which is attributable to progressive destruction of the coma grains with increasing space exposure. 41 refs

  9. Sedimentology, Behavior, and Hazards of Debris Flows at Mount Rainier, Washington

    Science.gov (United States)

    Scott, K.M.; Vallance, J.W.; Pringle, P.T.

    1995-01-01

    Mount Rainier is potentially the most dangerous volcano in the Cascade Range because of its great height, frequent earthquakes, active hydrothermal system, and extensive glacier mantle. Many debris flows and their distal phases have inundated areas far from the volcano during postglacial time. Two types of debris flows, cohesive and noncohesive, have radically different origins and behavior that relate empirically to clay content. The two types are the major subpopulations of debris flows at Mount Rainier. The behavior of cohesive flows is affected by the cohesion and adhesion of particles; noncohesive flows are dominated by particle collisions to the extent that particle cataclasis becomes common during near-boundary shear. Cohesive debris flows contain more than 3 to 5 percent of clay-size sediment. The composition of these flows changed little as they traveled more than 100 kilometers from Mount Rainier to inundate parts of the now-populated Puget Sound lowland. They originate as deep-seated failures of sectors of the volcanic edifice, and such failures are sufficiently frequent that they are the major destructional process of Mount Rainier's morphologic evolution. In several deposits of large cohesive flows, a lateral, megaclast-bearing facies (with a mounded or hummocky surface) contrasts with a more clay-rich facies in the center of valleys and downstream. Cohesive flows at Mount Rainier do not correlate strongly with volcanic activity and thus can recur without warning, possibly triggered by non-magmatic earthquakes or by changes in the hydrothermal system. Noncohesive debris flows contain less than 3 to 5 percent clay-size sediment. They form most commonly by bulking of sediment in water surges, but some originate directly or indirectly from shallow slope failures that do not penetrate the hydrothermally altered core of the volcano. In contrast with cohesive flows, most noncohesive flows transform both from and to other flow types and are, therefore, the

  10. Programmable CCD imaging system for synchrotron radiation studies

    International Nuclear Information System (INIS)

    Rodricks, B.; Brizard, C.

    1992-01-01

    A real-time imaging system for x-ray detection has been developed. The CAMAC-based system has a Charge Coupled Device (CCD) as its active detection element. The electronics consist of a CAMAC-crate-based dedicated microprocessor coupled to arbitrary waveform generators, programmable timing, and ADC modules. The hardware flexibility achievable through this system enables one to use virtually any commercially available CCD. A dedicated CAMAC-based display driver allows for real-time imaging on a high-resolution color monitor. An optional front end consisting of a fiber-optic taper and a focusing optical lens system coupled to a phosphor screen allows for large area imaging. Further, programming flexibility, in which the detector can be used in different read-out modes, enables it to be exploited for time-resolved experiments. In one mode, sections of the CCD can be read-out with millisecond time-resolution and, in another, the use of the CCD as a storage device is exploited resulting in microsecond time-resolution. Three different CCDs with radically different read-out timings and waveforms have been tested: the TI 4849, a 39Ox584 pixel array; TC 215, a 1024x1O24 pixel array; and the TH 7883, a 576x384 pixel array. The TC 215 and TI 4849 are single-phase CCDs manufactured by Texas Instruments, and the TH 7883 is a four-phase device manufactured by Thomson-CSF. The CCD characterized for uniformity, charge transfer efficiency (CTE), linearity, and sensitivity is the TC215

  11. Characterization of a pnCCD for applications with synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Send, S., E-mail: send@physik.uni-siegen.de [University of Siegen, Department of Physics, Walter-Flex-Straße 3, 57068 Siegen (Germany); Abboud, A. [University of Siegen, Department of Physics, Walter-Flex-Straße 3, 57068 Siegen (Germany); Hartmann, R.; Huth, M. [PNSensor GmbH, Römerstraße 28, 80803 München (Germany); Leitenberger, W. [University of Potsdam, Department of Physics, Karl-Liebknecht-Straße 24/25, 14476 Potsdam (Germany); Pashniak, N. [University of Siegen, Department of Physics, Walter-Flex-Straße 3, 57068 Siegen (Germany); Schmidt, J. [PNSensor GmbH, Römerstraße 28, 80803 München (Germany); Strüder, L. [University of Siegen, Department of Physics, Walter-Flex-Straße 3, 57068 Siegen (Germany); PNSensor GmbH, Römerstraße 28, 80803 München (Germany); Max-Planck-Institut für extraterrestrische Physik, Giessenbachstraße, 85748 Garching (Germany); Pietsch, U. [University of Siegen, Department of Physics, Walter-Flex-Straße 3, 57068 Siegen (Germany)

    2013-05-21

    In this work we study the response of a pnCCD by means of X-ray spectroscopy in the energy range between 6 keV and 20 keV and by Laue diffraction techniques. The analyses include measurements of characteristic detector parameters like energy resolution, count rate capability and effects of different gain settings. The limit of a single photon counting operation in white beam X-ray diffraction experiments is discussed with regard to the occurrence of pile-up events, for which the energy information about individual photons is lost. In case of monochromatic illumination the pnCCD can be used as a fast conventional CCD with a charge handling capacity (CHC) of about 300,000 electrons per pixel. If the CHC is exceeded, any surplus charge will spill to neighboring pixels perpendicular to the transfer direction due to electrostatic repulsion. The possibilities of increasing the number of storable electrons are investigated for different voltage settings by exposing a single pixel with X-rays generated by a microfocus X-ray source. The pixel binning mode is tested as an alternative approach that enables a pnCCD operation with significantly shorter readout times. -- Highlights: ► The pnCCD acts as a four-dimensional detector for white X-rays. ► Its performance for applications with synchrotron radiation is investigated. ► The pnCCD can be used for single photon counting and photon integration. ► The operation mode depends on the local frequencies of pile-up events. ► The pnCCD can be optimized for X-ray spectroscopy and X-ray imaging.

  12. Distal corporoplasty for distal cylinders extrusion after penile prosthesis implantation.

    Science.gov (United States)

    Carrino, Maurizio; Chiancone, Francesco; Battaglia, Gaetano; Pucci, Luigi; Fedelini, Paolo

    2017-02-03

    Distal extrusion of cylinders is a potential complication of the penile prosthesis implantation. Several methods have been proposed for repairing a distal penile erosion. We present our preliminary experience in "Distal corporoplasty" technique. We enrolled 18 consecutive patients whose underwent a distal corporoplasty with simultaneous reimplantation of an "AMS 700 inflatable penile prosthesis (LGX)" from January 2013 to November 2015 at our hospital. All procedures were performed by a single surgical team. Intraoperative and postoperative complications have been classified and reported according to Satava6 and Clavien-Dindo (CD) system.7 Mean values with standard deviations (±SD) were computed and reported for all items. Mean age of the patients was 53.61 (±11.90) years. Mean body max index (BMI) was 24.22 (±2.51). Mean operative time was 85.2 (±13.1) minutes. Blood losses were minimal. No intraoperative complications are reported according to Satava classification. Four out of 18 patients (22.22%) experienced postoperative complications according to CD system. All patients had sexual intercourse for the first time postsurgery after a mean of 59.11 ± 2.08 days. Mean follow-up was 22.11 (±9.95). Distal extrusion of cylinders is a potential complication of the penile prosthesis implantation. Distal corporoplasty was first described by Mulcahy. He reported a series of 14 patients with a follow-up of about 2 years with optimal functional outcomes. Moreover, distal corporoplasty resulted in shorter operative time, better function, less pain, and fewer recurrences than Gortex windsock repair.10 In our experience, distal corporoplasty is a simple and safe procedure in the treatment of distal cylinders extrusion when the prosthetic material is not exposed to the exterior.

  13. Software design of control system of CCD side-scatter lidar

    Science.gov (United States)

    Kuang, Zhiqiang; Liu, Dong; Deng, Qian; Zhang, Zhanye; Wang, Zhenzhu; Yu, Siqi; Tao, Zongming; Xie, Chenbo; Wang, Yingjian

    2018-03-01

    Because of the existence of blind zone and transition zone, the application of backscattering lidar in near-ground is limited. The side-scatter lidar equipped with the Charge Coupled Devices (CCD) can separate the transmitting and receiving devices to avoid the impact of the geometric factors which is exited in the backscattering lidar and, detect the more precise near-ground aerosol signals continuously. Theories of CCD side-scatter lidar and the design of control system are introduced. The visible control of laser and CCD and automatic data processing method of the side-scatter lidar are developed by using the software of Visual C #. The results which are compared with the calibration of the atmospheric aerosol lidar data show that signals from the CCD side- scatter lidar are convincible.

  14. A new approach to modelling radiation noise in CCD's

    International Nuclear Information System (INIS)

    Chugg, A.; Hopkinson, G.

    1998-01-01

    The energy depositions reported by Monte Carlo electron-photon irradiation transport codes are subject to a random error due to the finite number of particle histories used to generate the results. These statistical variations, normally a nuisance, may also be identified with the real radiation noise effects experienced by CCD pixels in persistent radiation environments. This paper explores the practicability of such radiation noise modelling by applying the ACCEPT code from the ITS suite to the case of a shielded CCD exposed to an electron flux. The results are compared with those obtained in a subsequent electron irradiation of the CCD by a Van de Graaff accelerator

  15. The interaction of DNA gyrase with the bacterial toxin CcdB

    DEFF Research Database (Denmark)

    Kampranis, S C; Howells, A J; Maxwell, A

    1999-01-01

    CcdB is a bacterial toxin that targets DNA gyrase. Analysis of the interaction of CcdB with gyrase reveals two distinct complexes. An initial complex (alpha) is formed by direct interaction between GyrA and CcdB; this complex can be detected by affinity column and gel-shift analysis, and has...... of this initial complex with ATP in the presence of GyrB and DNA slowly converts it to a second complex (beta), which has a lower rate of ATP hydrolysis and is unable to catalyse supercoiling. The efficiency of formation of this inactive complex is dependent on the concentrations of ATP and CcdB. We suggest...

  16. Discriminação de variedades de citros em imagens CCD/CBERS-2 Discrimination of citrus varieties using CCD/CBERS-2 satellite imagery

    Directory of Open Access Journals (Sweden)

    Ieda Del'Arco Sanches

    2008-02-01

    Full Text Available O presente trabalho teve o objetivo de avaliar as imagens CCD/CBERS-2 quanto à possibilidade de discriminarem variedades de citros. A área de estudo localiza-se em Itirapina (SP e, para este estudo, foram utilizadas imagens CCD de três datas (30/05/2004, 16/08/2004 e 11/09/2004. Um modelo que integra os elementos componentes da cena citrícola sensoriada é proposto com o objetivo de explicar a variabilidade das respostas das parcelas de citros em imagens orbitais do tipo CCD/CBERS-2. Foram feitas classificações pelos algoritmos Isoseg e Maxver e, de acordo com o índice kappa, concluiu-se que é possível obterem-se exatidões qualificadas como muito boas, sendo que as melhores classificações foram conseguidas com imagens da estação seca.This paper was aimed at evaluating the possibility of discriminating citrus varieties in CCD imageries from CBERS-2 satellite ("China-Brazil Earth Resouces Satellite". The study area is located in Itirapina, São Paulo State. For this study, three CCD images from 2004 were acquired (May 30, August 16, and September 11. In order to acquire a better understanding and for explaining the variability of the spectral behavior of the citrus areas in orbital images (like as the CCD/CBERS-2 images a model that integrates the elements of the citrus scene is proposed and discussed. The images were classified by Isoseg and MaxVer classifiers. According to kappa index, it was possible to obtain classifications qualified as 'very good'. The best results were obtained with the images from the dry season.

  17. A self triggered intensified Ccd (Stic)

    International Nuclear Information System (INIS)

    Charon, Y.; Laniece, P.; Bendali, M.

    1990-01-01

    We are developing a new device based on the results reported previously of the successfull coincidence detection of β- particles with a high spatial resolution [1]. The novelty of the device consists in triggering an intensified CCD, i.e. a CCD coupled to an image intensifier (II), by an electrical signal collected from the II itself. This is a suitable procedure for detecting with high efficiency and high resolution low light rare events. The trigger pulse is obtained from the secondary electrons produced by multiplication in a double microchannel plate (MCP) and collected on the aluminized layer protecting the phosphor screen in the II. Triggering efficiencies up to 80% has been already achieved

  18. Colony Collapse Disorder (CCD) and bee age impact honey bee pathophysiology.

    Science.gov (United States)

    vanEngelsdorp, Dennis; Traynor, Kirsten S; Andree, Michael; Lichtenberg, Elinor M; Chen, Yanping; Saegerman, Claude; Cox-Foster, Diana L

    2017-01-01

    Honey bee (Apis mellifera) colonies continue to experience high annual losses that remain poorly explained. Numerous interacting factors have been linked to colony declines. Understanding the pathways linking pathophysiology with symptoms is an important step in understanding the mechanisms of disease. In this study we examined the specific pathologies associated with honey bees collected from colonies suffering from Colony Collapse Disorder (CCD) and compared these with bees collected from apparently healthy colonies. We identified a set of pathological physical characteristics that occurred at different rates in CCD diagnosed colonies prior to their collapse: rectum distension, Malpighian tubule iridescence, fecal matter consistency, rectal enteroliths (hard concretions), and venom sac color. The multiple differences in rectum symptomology in bees from CCD apiaries and colonies suggest effected bees had trouble regulating water. To ensure that pathologies we found associated with CCD were indeed pathologies and not due to normal changes in physical appearances that occur as an adult bee ages (CCD colonies are assumed to be composed mostly of young bees), we documented the changes in bees of different ages taken from healthy colonies. We found that young bees had much greater incidences of white nodules than older cohorts. Prevalent in newly-emerged bees, these white nodules or cellular encapsulations indicate an active immune response. Comparing the two sets of characteristics, we determined a subset of pathologies that reliably predict CCD status rather than bee age (fecal matter consistency, rectal distension size, rectal enteroliths and Malpighian tubule iridescence) and that may serve as biomarkers for colony health. In addition, these pathologies suggest that CCD bees are experiencing disrupted excretory physiology. Our identification of these symptoms is an important first step in understanding the physiological pathways that underlie CCD and factors

  19. Colony Collapse Disorder (CCD and bee age impact honey bee pathophysiology.

    Directory of Open Access Journals (Sweden)

    Dennis vanEngelsdorp

    Full Text Available Honey bee (Apis mellifera colonies continue to experience high annual losses that remain poorly explained. Numerous interacting factors have been linked to colony declines. Understanding the pathways linking pathophysiology with symptoms is an important step in understanding the mechanisms of disease. In this study we examined the specific pathologies associated with honey bees collected from colonies suffering from Colony Collapse Disorder (CCD and compared these with bees collected from apparently healthy colonies. We identified a set of pathological physical characteristics that occurred at different rates in CCD diagnosed colonies prior to their collapse: rectum distension, Malpighian tubule iridescence, fecal matter consistency, rectal enteroliths (hard concretions, and venom sac color. The multiple differences in rectum symptomology in bees from CCD apiaries and colonies suggest effected bees had trouble regulating water. To ensure that pathologies we found associated with CCD were indeed pathologies and not due to normal changes in physical appearances that occur as an adult bee ages (CCD colonies are assumed to be composed mostly of young bees, we documented the changes in bees of different ages taken from healthy colonies. We found that young bees had much greater incidences of white nodules than older cohorts. Prevalent in newly-emerged bees, these white nodules or cellular encapsulations indicate an active immune response. Comparing the two sets of characteristics, we determined a subset of pathologies that reliably predict CCD status rather than bee age (fecal matter consistency, rectal distension size, rectal enteroliths and Malpighian tubule iridescence and that may serve as biomarkers for colony health. In addition, these pathologies suggest that CCD bees are experiencing disrupted excretory physiology. Our identification of these symptoms is an important first step in understanding the physiological pathways that underlie CCD and

  20. Distal digital replantation.

    Science.gov (United States)

    Jazayeri, Leila; Klausner, Jill Q; Chang, James

    2013-11-01

    Hand surgeons have been hesitant to perform distal digital replantation because of the technical challenges and the perception of a high cost-to-benefit ratio. Recent studies, however, have shown high survival rates and excellent functional and aesthetic results, providing renewed enthusiasm for distal replantation. The authors reviewed the literature and summarize key points regarding the surgical treatment, perioperative care, and outcomes of distal digital replantation. They describe specific techniques and considerations for surgical repair in each of four distal zones as described by Sebastin and Chung. Zone 1A replantation involves an artery-only anastomosis of a longitudinal pulp artery. Venous anastomosis first becomes possible in zone 1B. Zone 1C involves periarticular amputations where arthrodesis of the distal interphalangeal joint is usually indicated. Repair of the artery, vein, and nerve is technically optimal in zone 1D, where venous anastomosis should be performed. Overall, survival rates for distal digital replantation are similar to those reported for more proximal replantation. The literature reports good outcomes regarding nail salvage, fingertip sensibility, and range of motion, with restoration of length and aesthetic appearance. Distal replantation performed at institutions that specialize in microsurgery and specifically tailored to the level of injury is associated with good survival, function, and patient satisfaction and superior aesthetic outcome. More prospective data are needed to evaluate the cost of treatment, psychological outcomes, and functional outcomes of distal replantation compared with revision amputation.

  1. pnCCD for photon detection from near-infrared to X-rays

    International Nuclear Information System (INIS)

    Meidinger, Norbert; Andritschke, Robert; Hartmann, Robert; Herrmann, Sven; Holl, Peter; Lutz, Gerhard; Strueder, Lothar

    2006-01-01

    A pnCCD is a special type of charge-coupled device developed for spectroscopy and imaging of X-rays with high time resolution and quantum efficiency. Its most famous application is the operation on the XMM-Newton satellite, an X-ray astronomy mission that was launched by the European space agency in 1999. The excellent performance of the focal plane camera has been maintained for more than 6 years in orbit. The energy resolution in particular has shown hardly any degradation since launch. In order to satisfy the requirements of future X-ray astronomy missions as well as those of ground-based experiments, a new type of pnCCD has been developed. This 'frame-store pnCCD' shows an enhanced performance compared to the XMM-Newton type of pnCCD. Now, more options in device design and operation are available to tailor the detector to its respective application. Part of this concept is a programmable analog signal processor, which has been developed for the readout of the CCD signals. The electronic noise of the new detector has a value of only 2 electrons equivalent noise charge (ENC), which is less than half of the figure achieved for the XMM-Newton-type pnCCD. The energy resolution for the Mn-K α line at 5.9 keV is approximately 130 eV FWHM. We have close to 100% quantum efficiency for both low- and high-energy photon detection (e.g. the C-K line at 277 eV, and the Ge-K α line at 10 keV, respectively). Very high frame rates of 1000 images/s have been achieved due to the ultra-fast readout accomplished by the parallel architecture of the pnCCD and the analog signal processor. Excellent spectroscopic performance is shown even at the relatively high operating temperature of -25 deg. C that can be achieved by a Peltier cooler. The applications of the low-noise and fast pnCCD detector are not limited to the detection of X-rays. With an anti-reflective coating deposited on the photon entrance window, we achieve high quantum efficiency also for near-infrared and optical

  2. Timing generator of scientific grade CCD camera and its implementation based on FPGA technology

    Science.gov (United States)

    Si, Guoliang; Li, Yunfei; Guo, Yongfei

    2010-10-01

    The Timing Generator's functions of Scientific Grade CCD Camera is briefly presented: it generates various kinds of impulse sequence for the TDI-CCD, video processor and imaging data output, acting as the synchronous coordinator for time in the CCD imaging unit. The IL-E2TDI-CCD sensor produced by DALSA Co.Ltd. use in the Scientific Grade CCD Camera. Driving schedules of IL-E2 TDI-CCD sensor has been examined in detail, the timing generator has been designed for Scientific Grade CCD Camera. FPGA is chosen as the hardware design platform, schedule generator is described with VHDL. The designed generator has been successfully fulfilled function simulation with EDA software and fitted into XC2VP20-FF1152 (a kind of FPGA products made by XILINX). The experiments indicate that the new method improves the integrated level of the system. The Scientific Grade CCD camera system's high reliability, stability and low power supply are achieved. At the same time, the period of design and experiment is sharply shorted.

  3. CCD characterization and measurements automation

    Czech Academy of Sciences Publication Activity Database

    Kotov, I.V.; Frank, J.; Kotov, A.I.; Kubánek, Petr; O´Connor, P.; Prouza, Michael; Radeka, V.; Takacs, P.

    2012-01-01

    Roč. 695, Dec (2012), 188-192 ISSN 0168-9002 R&D Projects: GA MŠk ME09052 Institutional research plan: CEZ:AV0Z10100502 Keywords : CCD * characterization * test automation Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 1.142, year: 2012

  4. PV module mounting method and mounting assembly

    Science.gov (United States)

    Lenox, Carl J.S.; Johnson, Kurt M.

    2013-04-23

    A method for mounting PV modules to a deck includes selecting PV module layout pattern so that adjacent PV module edges are spaced apart. PV mounting and support assemblies are secured to the deck according to the layout pattern using fasteners extending into the deck. The PV modules are placed on the PV mounting and support assemblies. Retaining elements are located over and secured against the upper peripheral edge surfaces of the PV modules so to secure them to the deck with the peripheral edges of the PV modules spaced apart from the deck. In some examples a PV module mounting assembly, for use on a shingled deck, comprises flashing, a base mountable on the flashing, a deck-penetrating fastener engageable with the base and securable to the deck so to secure the flashing and the base to the shingled deck, and PV module mounting hardware securable to the base.

  5. Maxillary molar distalization with the dual-force distalizer supported by mini-implants: a clinical study.

    Science.gov (United States)

    Oberti, Giovanni; Villegas, Carlos; Ealo, Martha; Palacio, John Camilo; Baccetti, Tiziano

    2009-03-01

    The objective of this prospective study was to describe the clinical effects of a bone-supported molar distalizing appliance, the dual-force distalizer. The study group included 16 patients (mean age, 14.3 years) with Class II molar relationships. Study models and lateral cephalograms were taken before and after the distalizing movement to record significant dental and skeletal changes (Wilcoxon test). The average distalization time was 5 months, with a movement rate of 1.2 mm per month; the distalization amounts were 5.9 +/- 1.72 mm at the crown level and 4.4 +/- 1.41 mm at the furcation level. The average molar inclination was 5.6 degrees +/- 3.7 degrees ; this was less than the amount of inclination generated by bone-supported appliances that use single distalizing forces. The correlation between inclination and distalization was not significant, indicating predominantly bodily movement. The teeth anterior to the first molar moved distally also; the second premolars distalized an average of 4.26 mm, and the incisors retruded by 0.53 mm. The dual-force distalizer is a valid alternative distalizing appliance that generates controlled molar distalization with a good rate of movement and no loss of anchorage.

  6. Design and Development of Multi-Purpose CCD Camera System with Thermoelectric Cooling: Hardware

    Directory of Open Access Journals (Sweden)

    Y.-W. Kang

    2007-12-01

    Full Text Available We designed and developed a multi-purpose CCD camera system for three kinds of CCDs; KAF-0401E(768×512, KAF-1602E(1536×1024, KAF-3200E(2184×1472 made by KODAK Co.. The system supports fast USB port as well as parallel port for data I/O and control signal. The packing is based on two stage circuit boards for size reduction and contains built-in filter wheel. Basic hardware components include clock pattern circuit, A/D conversion circuit, CCD data flow control circuit, and CCD temperature control unit. The CCD temperature can be controlled with accuracy of approximately 0.4° C in the max. range of temperature, Δ 33° C. This CCD camera system has with readout noise 6 e^{-}, and system gain 5 e^{-}/ADU. A total of 10 CCD camera systems were produced and our tests show that all of them show passable performance.

  7. Study of x-ray CCD image sensor and application

    Science.gov (United States)

    Wang, Shuyun; Li, Tianze

    2008-12-01

    In this paper, we expounded the composing, specialty, parameter, its working process, key techniques and methods for charge coupled devices (CCD) twice value treatment. Disposal process for CCD video signal quantification was expatiated; X-ray image intensifier's constitutes, function of constitutes, coupling technique of X-ray image intensifier and CCD were analyzed. We analyzed two effective methods to reduce the harm to human beings when X-ray was used in the medical image. One was to reduce X-ray's radiation and adopt to intensify the image penetrated by X-ray to gain the same effect. The other was to use the image sensor to transfer the images to the safe area for observation. On this base, a new method was presented that CCD image sensor and X-ray image intensifier were combined organically. A practical medical X-ray photo electricity system was designed which can be used in the records and time of the human's penetrating images. The system was mainly made up with the medical X-ray, X-ray image intensifier, CCD vidicon with high resolution, image processor, display and so on. Its characteristics are: change the invisible X-ray into the visible light image; output the vivid images; short image recording time etc. At the same time we analyzed the main aspects which affect the system's resolution. Medical photo electricity system using X-ray image sensor can reduce the X-ray harm to human sharply when it is used in the medical diagnoses. At last we analyzed and looked forward the system's application in medical engineering and the related fields.

  8. Experimental investigations of image quality in X-ray mammography with conventional screen film system (SFS), digital phosphor storage plate in/without magnification technique (CR) and digital CCD-technique (CCD)

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Wenkel, E.; Bautz, W.; Saebel, M.

    2001-01-01

    Comparison of image quality in X-ray mammography between conventional film screen film system (SFS), digital phosphor storage plate in and without magnification technique (CR) and digital CCD-technique (CCD). Radiograms of an RMI-mammography phantom were acquired using a conventional screen film system, three digital storage plate systems and two digital systems in CCD-technique. Additionally the radiograms of one digital phosphor storage plate system were post-processed regarding contrast and included in the comparison. The detectability of details was best with the digital mammography in CCD-technique. After confirming these promising results in clinical studies, digital mammography should be able to replace conventional screen film technique. (orig.)

  9. Modeling the impact of preflushing on CTE in proton irradiated CCD-based detectors

    Science.gov (United States)

    Philbrick, R. H.

    2002-04-01

    A software model is described that performs a "real world" simulation of the operation of several types of charge-coupled device (CCD)-based detectors in order to accurately predict the impact that high-energy proton radiation has on image distortion and modulation transfer function (MTF). The model was written primarily to predict the effectiveness of vertical preflushing on the custom full frame CCD-based detectors intended for use on the proposed Kepler Discovery mission, but it is capable of simulating many other types of CCD detectors and operating modes as well. The model keeps track of the occupancy of all phosphorous-silicon (P-V), divacancy (V-V) and oxygen-silicon (O-V) defect centers under every CCD electrode over the entire detector area. The integrated image is read out by simulating every electrode-to-electrode charge transfer in both the vertical and horizontal CCD registers. A signal level dependency on the capture and emission of signal is included and the current state of each electrode (e.g., barrier or storage) is considered when distributing integrated and emitted signal. Options for performing preflushing, preflashing, and including mini-channels are available on both the vertical and horizontal CCD registers. In addition, dark signal generation and image transfer smear can be selectively enabled or disabled. A comparison of the charge transfer efficiency (CTE) data measured on the Hubble space telescope imaging spectrometer (STIS) CCD with the CTE extracted from model simulations of the STIS CCD show good agreement.

  10. Deflection control system for prestressed concrete bridges by CCD camera. CCD camera ni yoru prestressed concrete kyo no tawami kanri system

    Energy Technology Data Exchange (ETDEWEB)

    Noda, Y.; Nakayama, Y.; Arai, T. (Kawada Construction Co. Ltd., Tokyo (Japan))

    1994-03-15

    For the long-span prestressed concrete bridge (continuous box girder and cable stayed bridge), the design and construction control becomes increasingly complicated as construction proceeds because of its cyclic works. This paper describes the method and operation of an automatic levelling module using CCD camera and the experimental results by this system. For this automatic levelling system, the altitude can be automatically measured by measuring the center location of gravity of the target on the bridge surface using CCD camera. The present deflection control system developed compares the measured value by the automatic levelling system with the design value obtained by the design calculation system, and manages them. From the real-time continuous measurement for the long term, in which the CCD camera was set on the bridge surface, it was found that the stable measurement accuracy can be obtained. Successful application of this system demonstrates that the system is an effective and efficient construction aid. 11 refs., 19 figs., 1 tab.

  11. One method for HJ-1-A HSI and CCD data fusion

    International Nuclear Information System (INIS)

    Xiong, Wencheng; Shao, Yun; Shen, Wenming; Xiao, Rulin; Fu, Zhuo; Shi, Yuanli

    2014-01-01

    HJ-1-A satellite, developed by China independently, was equipped with two sensors of Hyper Spectral Imager (HSI) and multispectral sensor (CCD). In this paper, we examine the benefits of combining data from CCD data (high-spatial-resolution, low-spectral-resolution image) with HSI data (low -spatial-resolution, high -spectral-resolution image). Due to the same imaging time and similar spectral regime, the CCD and HSI data can be registered with each other well, and the difference between CCD and HSI data mainly is systematic bias. The approach we have been investigating compares the spectral information present in the multispectral image to the spectral content in the hyperspectral image, and derives a set of equations to approximately acquire the systematic bias between the two sensors. The systematic bias is then applied to the interpolated high-spectral CCD image to produce a fused product. This fused image has the spectral resolution of the hyperspectral image (HSI) and the spatial resolution of the multispectral image (CCD). It is capable of full exploitation as a hyperspectral image. We evaluate this technique using the data of Honghe wetland and show both good spectral and visual fidelity. An analysis of SAM classification test case shows good result when compared to original image. All in all, the approach we developed here provides a means for fusing data from HJ-1-A satellite to produce a spatial-resolution-enhanced hyperspectral data cube that can be further analyzed by spectral classification and detection algorithms

  12. A model for measurement of noise in CCD digital-video cameras

    International Nuclear Information System (INIS)

    Irie, K; Woodhead, I M; McKinnon, A E; Unsworth, K

    2008-01-01

    This study presents a comprehensive measurement of CCD digital-video camera noise. Knowledge of noise detail within images or video streams allows for the development of more sophisticated algorithms for separating true image content from the noise generated in an image sensor. The robustness and performance of an image-processing algorithm is fundamentally limited by sensor noise. The individual noise sources present in CCD sensors are well understood, but there has been little literature on the development of a complete noise model for CCD digital-video cameras, incorporating the effects of quantization and demosaicing

  13. Evaluation of the Stryker S2 IM Nail Distal Targeting Device for reduction of radiation exposure: a case series study.

    Science.gov (United States)

    Anastopoulos, George; Ntagiopoulos, Panagiotis G; Chissas, Dionisios; Loupasis, George; Asimakopoulos, Antonios; Athanaselis, Eustratios; Megas, Panagiotis

    2008-10-01

    Distal locking is one challenging step during intramedullary nailing of femoral shaft fractures that can lead to an increase of radiation exposure. In the present study, the authors describe a technique for the distal locking of femoral nails, implementing a new targeting device in an attempt to reduce radiation exposure and operational time. Over a 2-year period, 127 consecutive cases of femoral shaft fractures were included in the study. All cases were treated with nailing of femoral shaft fractures with an unslotted reamed antegrade femoral nail and distal locking was performed with the use of a proximally mounted aiming device. Mean duration of the procedure was 63.5 18.1 min while the duration for distal locking was 6.6 +/- 2.6 min. In all successful cases, exposure from intraoperative fluoroscopy was 17.2 +/- 7.4 s for the whole operative procedure, and for distal locking was 2 shots, 1.35 s (range, 0.9-2.2 s) and 1.9 mGy (range, 1.1-2.9 mGy). Five cases (3.9%) were unsuccessful, but overall no intraoperative complications were encountered from the application of this technique. The ability of the device to correspond to the level of nail deformation and to properly identify the distal holes, reduced exposure to radiation compared to other published reports, and should be considered as a valuable tool for distal locking of femoral fractures.

  14. Noise analysis for CCD-based ultraviolet and visible spectrophotometry.

    Science.gov (United States)

    Davenport, John J; Hodgkinson, Jane; Saffell, John R; Tatam, Ralph P

    2015-09-20

    We present the results of a detailed analysis of the noise behavior of two CCD spectrometers in common use, an AvaSpec-3648 CCD UV spectrometer and an Ocean Optics S2000 Vis spectrometer. Light sources used include a deuterium UV/Vis lamp and UV and visible LEDs. Common noise phenomena include source fluctuation noise, photoresponse nonuniformity, dark current noise, fixed pattern noise, and read noise. These were identified and characterized by varying light source, spectrometer settings, or temperature. A number of noise-limiting techniques are proposed, demonstrating a best-case spectroscopic noise equivalent absorbance of 3.5×10(-4)  AU for the AvaSpec-3648 and 5.6×10(-4)  AU for the Ocean Optics S2000 over a 30 s integration period. These techniques can be used on other CCD spectrometers to optimize performance.

  15. A Bridge Deflection Monitoring System Based on CCD

    Directory of Open Access Journals (Sweden)

    Baohua Shan

    2016-01-01

    Full Text Available For long-term monitoring of the midspan deflection of Songjiazhuang cloverleaf junction on 309 national roads in Zibo city, this paper proposes Zhang’s calibration-based DIC deflection monitoring method. CCD cameras are used to track the change of targets’ position, Zhang’s calibration algorithm is introduced to acquire the intrinsic and extrinsic parameters of CCD cameras, and the DIC method is combined with Zhang’s calibration algorithm to measure bridge deflection. The comparative test between Zhang’s calibration and scale calibration is conducted in lab, and experimental results indicate that the proposed method has higher precision. According to the deflection monitoring scheme, the deflection monitoring software for Songjiazhuang cloverleaf junction is developed by MATLAB, and a 4-channel CCD deflection monitoring system for Songjiazhuang cloverleaf junction is integrated in this paper. This deflection monitoring system includes functions such as image preview, simultaneous collection, camera calibration, deflection display, and data storage. In situ deflection curves show a consistent trend; this suggests that the proposed method is reliable and is suitable for the long-term monitoring of bridge deflection.

  16. A large area cooled-CCD detector for electron microscopy

    International Nuclear Information System (INIS)

    Faruqi, A.R.; Andrews, H.N.; Raeburn, C.

    1994-01-01

    Large area cooled-CCDs are an excellent medium for (indirectly) recording electron images and electron diffraction patterns in real time and for use in electron tomography; real-time imaging is extremely useful in making rapid adjustments in the electron microscope. CCDs provide high sensitivity (useful for minimising dosage to radiation-sensitive biological specimen), good resolution, stable performance, excellent dynamic range and linearity and a reasonably fast readout.We have built an electron imaging device based on the EEV 1152 by 814 pixel CCD which is controlled from a unix based SUN Sparcstation operating under X-Windows. The incident 100 kV electrons are converted to visible light in a 0.5 mm thick YAG single crystal which is imaged through a lens on to the CCD.The CCD electronics is designed to be as flexible as possible and allows a wide variation in the readout speed to cater for the relatively fast application where readout noise is less critical and low readout noise applications where the extra few seconds of readout time are not significant. The CCD electronics is built in VME format which is controlled through a S-bus to VME driver. With two parallel channels of readout the whole image can be read out in similar 1 s (using the faster readout speed) with 16 bit precision and the image is displayed under X-Windows in a few seconds. The present readout works at 500 kHz and has a noise of similar 30 e rms per pixel. With a Peltier cooling device we can operate the CCD at similar -40 circle C which reduces the dark current adequately to allow exposures of up to several minutes. Several examples of patterns collected with the system on a Philips CM12 microscope will be presented. ((orig.))

  17. Single-Electron and Single-Photon Sensitivity with a Silicon Skipper CCD

    Science.gov (United States)

    Tiffenberg, Javier; Sofo-Haro, Miguel; Drlica-Wagner, Alex; Essig, Rouven; Guardincerri, Yann; Holland, Steve; Volansky, Tomer; Yu, Tien-Tien

    2017-09-01

    We have developed ultralow-noise electronics in combination with repetitive, nondestructive readout of a thick, fully depleted charge-coupled device (CCD) to achieve an unprecedented noise level of 0.068 e- rms /pixel . This is the first time that discrete subelectron readout noise has been achieved reproducible over millions of pixels on a stable, large-area detector. This enables the contemporaneous, discrete, and quantized measurement of charge in pixels, irrespective of whether they contain zero electrons or thousands of electrons. Thus, the resulting CCD detector is an ultra-sensitive calorimeter. It is also capable of counting single photons in the optical and near-infrared regime. Implementing this innovative non-destructive readout system has a negligible impact on CCD design and fabrication, and there are nearly immediate scientific applications. As a particle detector, this CCD will have unprecedented sensitivity to low-mass dark matter particles and coherent neutrino-nucleus scattering, while future astronomical applications may include direct imaging and spectroscopy of exoplanets.

  18. Development of CCD Imaging System Using Thermoelectric Cooling Method

    Directory of Open Access Journals (Sweden)

    Youngsik Park

    2000-06-01

    Full Text Available We developed low light CCD imaging system using thermoelectric cooling method collaboration with a company to design a commercial model. It consists of Kodak KAF-0401E (768x512 pixels CCD chip,thermoelectric module manufactured by Thermotek. This TEC system can reach an operative temperature of -25deg. We employed an Uniblitz VS25S shutter and it has capability a minimum exposure time 80ms. The system components are an interface card using a Korea Astronomy Observatory (hereafter KAO ISA bus controller, image acquisition with AD9816 chip, that is 12bit video processor. The performance test with this imaging system showed good operation within the initial specification of our design. It shows a dark current less than 0.4e-/pixel/sec at a temperature of -10deg, a linearity 99.9+/-0.1%, gain 4.24e-adu, and system noise is 25.3e- (rms. For low temperature CCD operation, we designed a TEC, which uses a one-stage peltier module and forced air heat exchanger. This TEC imaging system enables accurate photometry (+/-0.01mag even though the CCD is not at 'conventional' cryogenic temperatures (140K. The system can be a useful instrument for any other imaging applications. Finally, with this system, we obtained several images of astronomical objects for system performance tests.

  19. Research of optical coherence tomography microscope based on CCD detector

    Science.gov (United States)

    Zhang, Hua; Xu, Zhongbao; Zhang, Shuomo

    2008-12-01

    The reference wave phase was modulated with a sinusoidal vibrating mirror attached to a Piezoelectric Transducer (PZT), the integration was performed by a CCD, and the charge storage period of the CCD image sensor was one-quarter period of the sinusoidal phase modulation. With the frequency- synchronous detection technique, four images (four frames of interference pattern) were recorded during one period of the phase modulation. In order to obtain the optimum modulation parameter, the values of amplitude and phase of the sinusoidal phase modulation were determined by considering the measurement error caused by the additive noise contained in the detected values. The PZT oscillation was controlled by a closed loop control system based on PID controller. An ideal discrete digital sine function at 50Hz with adjustable amplitude was used to adjust the vibrating of PZT, and a digital phase shift techniques was used to adjust vibrating phase of PZT so that the phase of the modulation could reach their optimum values. The CCD detector was triggered with software at 200Hz. Based on work above a small coherent signal masked by the preponderant incoherent background with a CCD detector was obtained.

  20. Reverse Distal Transverse Palmar Arch in Distal Digital Replantation.

    Science.gov (United States)

    Wei, Ching-Yueh; Orozco, Oscar; Vinagre, Gustavo; Shafarenko, Mark

    2017-11-01

    Refinements in microsurgery have made distal finger replantation an established technique with high success rates and good functional and aesthetic outcomes. However, it still represents a technically demanding procedure due to the small vessel caliber and frequent lack of vessel length, requiring the use of interpositional venous grafts in some instances. We describe a new technique for anastomosis in fingertip replantation, whereby the need for venous grafts is eliminated. Applying the reverse distal transverse palmar arch technique, 11 cases of distal digital replantation were performed between January 2011 and July 2016. The described procedure was used for arterial anastomosis in 10 cases and arteriovenous shunting for venous drainage in 1 case. A retrospective case review was conducted. The technical description and clinical outcome evaluations are presented. Ten of the 11 replanted digits survived, corresponding to an overall success rate of 91%. One replant failed due to venous insufficiency. Blood transfusions were not required for any of the patients. Follow-up (range, 1.5-5 months) revealed near-normal range of motion and good aesthetic results. All of the replanted digits developed protective sensation. The average length of hospital admission was 5 days. All patients were satisfied with the results and were able to return to their previous work. The use of the reverse distal transverse palmar arch is a novel and reliable technique in distal digital replantation when an increase in vessel length is required, allowing for a tension-free arterial repair without the need for vein grafts.

  1. Investigation of radiation damage effects in neutron irradiated CCD

    International Nuclear Information System (INIS)

    Brau, James E.; Igonkina, Olga; Potter, Chris T.; Sinev, Nikolai B.

    2005-01-01

    A Charge Coupled Devices (CCD)-based vertex detector is a leading option for vertex detection at the future linear collider. A major issue for this application is the radiation hardness of such devices. Tests of radiation hardness of CCDs used in the SLD vertex detector, VXD3, have been reported earlier. The first measurements of 1998 involved a spare VXD3 CCD that was irradiated with neutrons from a radioactive source (Pu-Be), and from a nuclear reactor. In 2003, we had the opportunity to disassemble the VXD3 detector and study the nature of the radiation damage it incurred during 3 years of operation at SLC. In the preparation for this study, additional experiments with the spare VXD3 CCD were performed. These included measurements of trapping times in neutron irradiated CCDs. Results, reported here, will help us better understand the mechanism of radiation damage effects and develop techniques to minimize performance degradation due to radiation damage

  2. Photovoltaic mounting/demounting unit

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to a photovoltaic arrangement comprising a photovoltaic assembly comprising a support structure defining a mounting surface onto which a photovoltaic module is detachably mounted; and a mounting/demounting unit comprising at least one mounting/demounting apparatus...... which when the mounting/demounting unit is moved along the mounting surface, causes the photovoltaic module to be mounted or demounted to the support structure; wherein the photovoltaic module comprises a carrier foil and wherein a total thickness of the photo voltaic module is below 500 muiotaeta....... The present invention further relates to an associated method for mounting/demounting photovoltaic modules....

  3. Stroboscope Based Synchronization of Full Frame CCD Sensors.

    Science.gov (United States)

    Shen, Liang; Feng, Xiaobing; Zhang, Yuan; Shi, Min; Zhu, Dengming; Wang, Zhaoqi

    2017-04-07

    The key obstacle to the use of consumer cameras in computer vision and computer graphics applications is the lack of synchronization hardware. We present a stroboscope based synchronization approach for the charge-coupled device (CCD) consumer cameras. The synchronization is realized by first aligning the frames from different video sequences based on the smear dots of the stroboscope, and then matching the sequences using a hidden Markov model. Compared with current synchronized capture equipment, the proposed approach greatly reduces the cost by using inexpensive CCD cameras and one stroboscope. The results show that our method could reach a high accuracy much better than the frame-level synchronization of traditional software methods.

  4. The study of interferometer spectrometer based on DSP and linear CCD

    Science.gov (United States)

    Kang, Hua; Peng, Yuexiang; Xu, Xinchen; Xing, Xiaoqiao

    2010-11-01

    In this paper, general theory of Fourier-transform spectrometer and polarization interferometer is presented. A new design is proposed for Fourier-transform spectrometer based on polarization interferometer with Wollaston prisms and linear CCD. Firstly, measured light is changed into linear polarization light by polarization plate. And then the light can be split into ordinary and extraordinary lights by going through one Wollaston prism. At last, after going through another Wollaston prism and analyzer, interfering fringes can be formed on linear CCD behind the analyzer. The linear CCD is driven by CPLD to output amplitude of interfering fringes and synchronous signals of frames and pixels respectively. DSP is used to collect interference pattern signals from CCD and the digital data of interfering fringes are processed by using 2048-point-FFT. Finally, optical spectrum of measured light can be display on LCD connected to DSP with RS232. The spectrometer will possess the features of firmness, portability and the ability of real-time analyzing. The work will provide a convenient and significant foundation for application of more high accuracy of Fourier-transform spectrometer.

  5. CCD-based thermoreflectance microscopy: principles and applications

    International Nuclear Information System (INIS)

    Farzaneh, M; Maize, K; Shakouri, A; Lueerssen, D; Summers, J A; Hudgings, Janice A; Mayer, P M; Ram, R J; Raad, P E; Pipe, K P

    2009-01-01

    CCD-based thermoreflectance microscopy has emerged as a high resolution, non-contact imaging technique for thermal profiling and performance and reliability analysis of numerous electronic and optoelectronic devices at the micro-scale. This thermography technique, which is based on measuring the relative change in reflectivity of the device surface as a function of change in temperature, provides high-resolution thermal images that are useful for hot spot detection and failure analysis, mapping of temperature distribution, measurement of thermal transient, optical characterization of photonic devices and measurement of thermal conductivity in thin films. In this paper we review the basic physical principle behind thermoreflectance as a thermography tool, discuss the experimental setup, resolutions achieved, signal processing procedures and calibration techniques, and review the current applications of CCD-based thermoreflectance microscopy in various devices. (topical review)

  6. Converting structures to optimize the Synchrotron X radiation detection by CCD systems

    International Nuclear Information System (INIS)

    Zanella, G.; Zannoni, R.

    1987-01-01

    It is pointed out how the quantum efficiency of X ray detection for CCD detecting system can be improved enlarging their sensivity range by means of heavy element converting structures. So the problem of fabricating CCD with a deep emptying layer is avoided

  7. [Distal clavicle fracture].

    Science.gov (United States)

    Seppel, G; Lenich, A; Imhoff, A B

    2014-06-01

    Reposition and fixation of unstable distal clavicle fractures with a low profile locking plate (Acumed, Hempshire, UK) in conjunction with a button/suture augmentation cerclage (DogBone/FibreTape, Arthrex, Naples, FL, USA). Unstable fractures of the distal clavicle (Jäger and Breitner IIA) in adults. Unstable fractures of the distal clavicle (Jäger and Breitner IV) in children. Distal clavicle fractures (Jäger and Breitner I, IIB or III) with marked dislocation, injury of nerves and vessels, or high functional demand. Patients in poor general condition. Fractures of the distal clavicle (Jäger and Breitner I, IIB or III) without marked dislocation or vertical instability. Local soft-tissue infection. Combination procedure: Initially the lateral part of the clavicle is exposed by a 4 cm skin incision. After reduction of the fracture, stabilization is performed with a low profile locking distal clavicle plate. Using a special guiding device, a transclavicular-transcoracoidal hole is drilled under arthroscopic view. Additional vertical stabilization is arthroscopically achieved by shuttling the DogBone/FibreTape cerclage from the lateral portal cranially through the clavicular plate. The two ends of the FibreTape cerclage are brought cranially via adjacent holes of the locking plate while the DogBone button is placed under the coracoid process. Thus, plate bridging is achieved. Finally reduction is performed and the cerclage is secured by surgical knotting. Use of an arm sling for 6 weeks. Due to the fact that the described technique is a relatively new procedure, long-term results are lacking. In the short term, patients postoperatively report high subjective satisfaction without persistent pain.

  8. Design of area array CCD image acquisition and display system based on FPGA

    Science.gov (United States)

    Li, Lei; Zhang, Ning; Li, Tianting; Pan, Yue; Dai, Yuming

    2014-09-01

    With the development of science and technology, CCD(Charge-coupled Device) has been widely applied in various fields and plays an important role in the modern sensing system, therefore researching a real-time image acquisition and display plan based on CCD device has great significance. This paper introduces an image data acquisition and display system of area array CCD based on FPGA. Several key technical challenges and problems of the system have also been analyzed and followed solutions put forward .The FPGA works as the core processing unit in the system that controls the integral time sequence .The ICX285AL area array CCD image sensor produced by SONY Corporation has been used in the system. The FPGA works to complete the driver of the area array CCD, then analog front end (AFE) processes the signal of the CCD image, including amplification, filtering, noise elimination, CDS correlation double sampling, etc. AD9945 produced by ADI Corporation to convert analog signal to digital signal. Developed Camera Link high-speed data transmission circuit, and completed the PC-end software design of the image acquisition, and realized the real-time display of images. The result through practical testing indicates that the system in the image acquisition and control is stable and reliable, and the indicators meet the actual project requirements.

  9. A Design and Development of Multi-Purpose CCD Camera System with Thermoelectric Cooling: Software

    Directory of Open Access Journals (Sweden)

    S. H. Oh

    2007-12-01

    Full Text Available We present a software which we developed for the multi-purpose CCD camera. This software can be used on the all 3 types of CCD - KAF-0401E (768×512, KAF-1602E (15367times;1024, KAF-3200E (2184×1472 made in KODAK Co.. For the efficient CCD camera control, the software is operated with two independent processes of the CCD control program and the temperature/shutter operation program. This software is designed to fully automatic operation as well as manually operation under LINUX system, and is controled by LINUX user signal procedure. We plan to use this software for all sky survey system and also night sky monitoring and sky observation. As our results, the read-out time of each CCD are about 15sec, 64sec, 134sec for KAF-0401E, KAF-1602E, KAF-3200E., because these time are limited by the data transmission speed of parallel port. For larger format CCD, the data transmission is required more high speed. we are considering this control software to one using USB port for high speed data transmission.

  10. Design of offline measuring system for radiation damage effects on linear CCD

    International Nuclear Information System (INIS)

    Zhang Yong; Tang Benqi; Xiao Zhigang; Wang Zujun; Huang Fang; Huang Shaoyan

    2004-01-01

    The paper discusses the hardware design of offline measuring system for radiation damage effects on linear CCD. Some credible results were achieved by using this system. The test results indicate that the system is available for the study of the radiation damage effects on linear CCD. (authors)

  11. Optimization of polarimetry sensitivity for X-ray CCD

    CERN Document Server

    Hayashida, K; Tsunemi, H; Hashimoto, Y; Ohtani, M

    1999-01-01

    X-ray polarimetry with CCD has been performed using a polarized X-ray beam from an electron impact X-ray source. The standard data reduction method employing double-pixel events yields the modulation factor M of 0.14 at 27 keV and 0.24 at 43 keV for the 12 mu m pixel size CCD chip. We develop a new data reduction method, in which multi-pixel events are employed, and which approximates the charge spread as an oval shape. We optimize the reduction parameters, so that we improve the P sub m sub i sub n (minimum detectable polarization degree) by factor of three from the value obtained through the usual double-pixel event method.

  12. Stroboscope Based Synchronization of Full Frame CCD Sensors

    Directory of Open Access Journals (Sweden)

    Liang Shen

    2017-04-01

    Full Text Available The key obstacle to the use of consumer cameras in computer vision and computer graphics applications is the lack of synchronization hardware. We present a stroboscope based synchronization approach for the charge-coupled device (CCD consumer cameras. The synchronization is realized by first aligning the frames from different video sequences based on the smear dots of the stroboscope, and then matching the sequences using a hidden Markov model. Compared with current synchronized capture equipment, the proposed approach greatly reduces the cost by using inexpensive CCD cameras and one stroboscope. The results show that our method could reach a high accuracy much better than the frame-level synchronization of traditional software methods.

  13. Modelling charge storage in Euclid CCD structures

    International Nuclear Information System (INIS)

    Clarke, A S; Holland, A; Hall, D J; Burt, D

    2012-01-01

    The primary aim of ESA's proposed Euclid mission is to observe the distribution of galaxies and galaxy clusters, enabling the mapping of the dark architecture of the universe [1]. This requires a high performance detector, designed to endure a harsh radiation environment. The e2v CCD204 image sensor was redesigned for use on the Euclid mission [2]. The resulting e2v CCD273 has a narrower serial register electrode and transfer channel compared to its predecessor, causing a reduction in the size of charge packets stored, thus reducing the number of traps encountered by the signal electrons during charge transfer and improving the serial Charge Transfer Efficiency (CTE) under irradiation [3]. The proposed Euclid CCD has been modelled using the Silvaco TCAD software [4], to test preliminary calculations for the Full Well Capacity (FWC) and the channel potential of the device and provide indications of the volume occupied by varying signals. These results are essential for the realisation of the mission objectives and for radiation damage studies, with the aim of producing empirically derived formulae to approximate signal-volume characteristics in the devices. These formulae will be used in the radiation damage (charge trapping) models. The Silvaco simulations have been tested against real devices to compare the experimental measurements to those predicted in the models. Using these results, the implications of this study on the Euclid mission can be investigated in more detail.

  14. Spleen-preserving distal pancreatectomy in trauma.

    Science.gov (United States)

    Schellenberg, Morgan; Inaba, Kenji; Cheng, Vincent; Bardes, James M; Lam, Lydia; Benjamin, Elizabeth; Matsushima, Kazuhide; Demetriades, Demetrios

    2018-01-01

    Traumatic injuries to the distal pancreas are infrequent. Universally accepted recommendations about the need for routine splenectomy with distal pancreatectomy do not exist. The aims of this study were to compare outcomes after distal pancreatectomy and splenectomy versus spleen-preserving distal pancreatectomy, and to define the appropriate patient population for splenic preservation. All patients who underwent distal pancreatectomy (January 1, 2007, to December 31, 2014) were identified from the National Trauma Data Bank. Patients with concomitant splenic injury and those who underwent partial splenectomy were excluded. Demographics, clinical data, procedures, and outcomes were collected. Study groups were defined by surgical procedure: distal pancreatectomy and splenectomy versus spleen-preserving distal pancreatectomy. Baseline characteristics between groups were compared with univariate analysis. Multivariate analysis was performed with logistic and linear regression to examine differences in outcomes. Over the 8-year study period, 2,223 patients underwent distal pancreatectomy. After excluding 1,381 patients with concomitant splenic injury (62%) and 8 (pancreatectomy and splenectomy, those who underwent spleen-preserving distal pancreatectomy were younger (p pancreatectomy (p = 0.017). Complications, mortality, and intensive care unit LOS were not significantly different. In young patients after blunt trauma who are not severely injured, a spleen-preserving distal pancreatectomy should be considered to allow for conservation of splenic function and a shorter hospital LOS. In all other patients, the surgeon should not hesitate to remove the spleen with the distal pancreas. Therapy, level IV.

  15. Stellar CCD Photometry: New Approach, Principles and Application

    Science.gov (United States)

    El-Bassuny Alawy, A.

    A new approach is proposed and developed to handle pre-processed CCD frames in order to identify stellar images and derive their relevant parameters. It relies on: 1) Identifying stellar images and assigning approximate positions of their centres using an artificial intelligence technique, (Knowledge Based System), 2) Accurate determination of the centre co-ordinates applying an elementary statistical concept and 3) Estimating the image peak intensity as a stellar magnitude measure employing simple numerical analysis approach. The method has been coded for personal computer users. A CCD frame of the star cluster M67 was adopted as a test case. The results obtained are discussed in comparison with the DAOPHOTII ones and the corresponding published data. Exact coincidence has been found between both results except in very few cases. These exceptions have been discussed in the light of the basis of both methods and the cluster plates. It has been realised that the method suggested represents a very simple, extremely fast, high precision method of stellar CCD photometry. Moreover, it is more capable than DAOPHOTII of handling blended and distorted stellar images. These characteristics show the usefulness of the present method in some astronomical applications, such as auto-focusing and auto-guiding, beside the main purpose, viz. stellar photometry.

  16. Optical CT scanning of PRESAGETM polyurethane samples with a CCD-based readout system

    International Nuclear Information System (INIS)

    Doran, S J; Krstajic, N; Adamovics, J; Jenneson, P M

    2004-01-01

    This article demonstrates the resolution capabilities of the CCD scanner under ideal circumstances and describes the first CCD-based optical CT experiments on a new class of dosimeter, known as PRESAGE TM (Heuris Pharma, Skillman, NJ)

  17. Technical Note: Range verification system using edge detection method for a scintillator and a CCD camera system

    Energy Technology Data Exchange (ETDEWEB)

    Saotome, Naoya, E-mail: naosao@nirs.go.jp; Furukawa, Takuji; Hara, Yousuke; Mizushima, Kota; Tansho, Ryohei; Saraya, Yuichi; Shirai, Toshiyuki; Noda, Koji [Department of Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2016-04-15

    Purpose: Three-dimensional irradiation with a scanned carbon-ion beam has been performed from 2011 at the authors’ facility. The authors have developed the rotating-gantry equipped with the scanning irradiation system. The number of combinations of beam properties to measure for the commissioning is more than 7200, i.e., 201 energy steps, 3 intensities, and 12 gantry angles. To compress the commissioning time, quick and simple range verification system is required. In this work, the authors develop a quick range verification system using scintillator and charge-coupled device (CCD) camera and estimate the accuracy of the range verification. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. The optical spatial resolution of the system is 0.2 mm/pixel. The camera control system was connected and communicates with the measurement system that is part of the scanning system. The range was determined by image processing. Reference range for each energy beam was determined by a difference of Gaussian (DOG) method and the 80% of distal dose of the depth-dose distribution that were measured by a large parallel-plate ionization chamber. The authors compared a threshold method and a DOG method. Results: The authors found that the edge detection method (i.e., the DOG method) is best for the range detection. The accuracy of range detection using this system is within 0.2 mm, and the reproducibility of the same energy measurement is within 0.1 mm without setup error. Conclusions: The results of this study demonstrate that the authors’ range check system is capable of quick and easy range verification with sufficient accuracy.

  18. Technical Note: Range verification system using edge detection method for a scintillator and a CCD camera system

    International Nuclear Information System (INIS)

    Saotome, Naoya; Furukawa, Takuji; Hara, Yousuke; Mizushima, Kota; Tansho, Ryohei; Saraya, Yuichi; Shirai, Toshiyuki; Noda, Koji

    2016-01-01

    Purpose: Three-dimensional irradiation with a scanned carbon-ion beam has been performed from 2011 at the authors’ facility. The authors have developed the rotating-gantry equipped with the scanning irradiation system. The number of combinations of beam properties to measure for the commissioning is more than 7200, i.e., 201 energy steps, 3 intensities, and 12 gantry angles. To compress the commissioning time, quick and simple range verification system is required. In this work, the authors develop a quick range verification system using scintillator and charge-coupled device (CCD) camera and estimate the accuracy of the range verification. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. The optical spatial resolution of the system is 0.2 mm/pixel. The camera control system was connected and communicates with the measurement system that is part of the scanning system. The range was determined by image processing. Reference range for each energy beam was determined by a difference of Gaussian (DOG) method and the 80% of distal dose of the depth-dose distribution that were measured by a large parallel-plate ionization chamber. The authors compared a threshold method and a DOG method. Results: The authors found that the edge detection method (i.e., the DOG method) is best for the range detection. The accuracy of range detection using this system is within 0.2 mm, and the reproducibility of the same energy measurement is within 0.1 mm without setup error. Conclusions: The results of this study demonstrate that the authors’ range check system is capable of quick and easy range verification with sufficient accuracy.

  19. On-Line High Dose-Rate Gamma Ray Irradiation Test of the CCD/CMOS Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Wan; Jeong, Kyung Min [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    In this paper, test results of gamma ray irradiation to CCD/CMOS cameras are described. From the CAMS (containment atmospheric monitoring system) data of Fukushima Dai-ichi nuclear power plant station, we found out that the gamma ray dose-rate when the hydrogen explosion occurred in nuclear reactors 1{approx}3 is about 160 Gy/h. If assumed that the emergency response robot for the management of severe accident of the nuclear power plant has been sent into the reactor area to grasp the inside situation of reactor building and to take precautionary measures against releasing radioactive materials, the CCD/CMOS cameras, which are loaded with the robot, serve as eye of the emergency response robot. In the case of the Japanese Quince robot system, which was sent to carry out investigating the unit 2 reactor building refueling floor situation, 7 CCD/CMOS cameras are used. 2 CCD cameras of Quince robot are used for the forward and backward monitoring of the surroundings during navigation. And 2 CCD (or CMOS) cameras are used for monitoring the status of front-end and back-end motion mechanics such as flippers and crawlers. A CCD camera with wide field of view optics is used for monitoring the status of the communication (VDSL) cable reel. And another 2 CCD cameras are assigned for reading the indication value of the radiation dosimeter and the instrument. In the preceding assumptions, a major problem which arises when dealing with CCD/CMOS cameras in the severe accident situations of the nuclear power plant is the presence of high dose-rate gamma irradiation fields. In the case of the DBA (design basis accident) situations of the nuclear power plant, in order to use a CCD/CMOS camera as an ad-hoc monitoring unit in the vicinity of high radioactivity structures and components of the nuclear reactor area, a robust survivability of this camera in such intense gamma-radiation fields therefore should be verified. The CCD/CMOS cameras of various types were gamma irradiated at a

  20. Photovoltaic module mounting system

    Science.gov (United States)

    Miros, Robert H. J. [Fairfax, CA; Mittan, Margaret Birmingham [Oakland, CA; Seery, Martin N [San Rafael, CA; Holland, Rodney H [Novato, CA

    2012-04-17

    A solar array mounting system having unique installation, load distribution, and grounding features, and which is adaptable for mounting solar panels having no external frame. The solar array mounting system includes flexible, pedestal-style feet and structural links connected in a grid formation on the mounting surface. The photovoltaic modules are secured in place via the use of attachment clamps that grip the edge of the typically glass substrate. The panel mounting clamps are then held in place by tilt brackets and/or mid-link brackets that provide fixation for the clamps and align the solar panels at a tilt to the horizontal mounting surface. The tilt brackets are held in place atop the flexible feet and connected link members thus creating a complete mounting structure.

  1. Comparison of standard laparoscopic distal pancreatectomy with minimally invasive distal pancreatectomy using the da Vinci S system.

    Science.gov (United States)

    Ito, Masahiro; Asano, Yukio; Shimizu, Tomohiro; Uyama, Ichiro; Horiguchi, Akihiko

    2014-01-01

    Minimally invasive procedures for pancreatic pathologies are increasingly being used, including distal pancreatectomy. This study aimed to assess the indications for and outcomes of the da Vinci distal pancreatectomy procedure. We reviewed the medical records of patients who underwent pancreatic head resection from April 2009 to September 2013. Four patients (mean age, 52.7 years) underwent da Vinci distal pancreatectomy and 10 (mean age, 68.0 +/- 12.1 years) underwent laparoscopic distal pancreatectomy. The mean surgical duration was 292 +/- 153 min and 306 +/- 29 min, the mean blood loss was 153 +/- 71 mL and 61.7 +/- 72 mL, and the mean postoperative length of stay was 24 +/- 11 days and 14 +/- 3 days in the da Vinci distal pancreatectomy and laparoscopic distal pancreatectomy groups, respectively. One patient who underwent da Vinci distal pancreatectomy developed a pancreatic fistula, while 2 patients in the laparoscopic distal pancreatectomy group developed splenic ischemia and gastric torsion, respectively. Laparoscopic and robotic pancreatic resection were both safe and feasible in selected patients with distal pancreatic pathologies. Further studies are necessary to clarify the role of robotic surgery in the advanced laparoscopic era.

  2. A nondestructive, reproducible method of measuring joint reaction force at the distal radioulnar joint.

    Science.gov (United States)

    Canham, Colin D; Schreck, Michael J; Maqsoodi, Noorullah; Doolittle, Madison; Olles, Mark; Elfar, John C

    2015-06-01

    To develop a nondestructive method of measuring distal radioulnar joint (DRUJ) joint reaction force (JRF) that preserves all periarticular soft tissues and more accurately reflects in vivo conditions. Eight fresh-frozen human cadaveric limbs were obtained. A threaded Steinmann pin was placed in the middle of the lateral side of the distal radius transverse to the DRUJ. A second pin was placed into the middle of the medial side of the distal ulna colinear to the distal radial pin. Specimens were mounted onto a tensile testing machine using a custom fixture. A uniaxial distracting force was applied across the DRUJ while force and displacement were simultaneously measured. Force-displacement curves were generated and a best-fit polynomial was solved to determine JRF. All force-displacement curves demonstrated an initial high slope where relatively large forces were required to distract the joint. This ended with an inflection point followed by a linear area with a low slope, where small increases in force generated larger amounts of distraction. Each sample was measured 3 times and there was high reproducibility between repeated measurements. The average baseline DRUJ JRF was 7.5 N (n = 8). This study describes a reproducible method of measuring DRUJ reaction forces that preserves all periarticular stabilizing structures. This technique of JRF measurement may also be suited for applications in the small joints of the wrist and hand. Changes in JRF can alter native joint mechanics and lead to pathology. Reliable methods of measuring these forces are important for determining how pathology and surgical interventions affect joint biomechanics. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. An innovative technique to distalize maxillary molar using microimplant supported rapid molar distalizer

    Directory of Open Access Journals (Sweden)

    Meenu Goel

    2013-01-01

    Full Text Available Introduction: In recent years, enhancements in implants have made their use possible as a mode of absolute anchorage in orthodontic patients. In this paper, the authors have introduced an innovative technique to unilaterally distalize the upper left 1 st molar to obtain an ideal Class I molar relationship from a Class II existing molar relationship with an indigenous designed distalizer. Clinical Innovation: For effective unilateral diatalization of molar, a novel cantilever sliding jig assembly was utilized with coil spring supported by a buccally placed single micro implant. The results showed 3 mm of bodily distalization with 1 mm of intrusion and 2° of distal tipping of upper left 1 st molar in 1.5 months. Discussion: This appliance is relatively easy to insert, well-tolerated, and requires minimal patient cooperation compared to other present techniques of molar distalization. Moreover, it is particularly useful in cases that are Class II on one side and Class I on the other, with a minor midline discrepancy and nominal overjet. Patient acceptance level was reported to be within patients physiological and comfort limits.

  4. Magnetic core mounting system

    Science.gov (United States)

    Ronning, Jeffrey J.

    2002-01-01

    A mounting apparatus for an electromagnetic device such as a transformer of inductor includes a generally planar metallic plate as a first heat sink, and a metallic mounting cup as a second heat sink. The mounting cup includes a cavity configured to receive the electromagnetic device, the cavity being defined by a base, and an axially-extending annular sidewall extending from the base to a flange portion of the mounting cup. The mounting cup includes first and second passages for allowing the leads of first and second windings of the electromagnetic device to be routed out of the cavity. The cavity is filled with a polyurethane potting resin, and the mounting cup, including the potted electromagnetic device, is mounted to the plate heat sink using fasteners. The mounting cup, which surrounds the electromagnetic device, in combination with the potting resin provides improved thermal transfer to the plate heat sink, as well as providing resistance to vibration and shocks.

  5. Distal renal tubular acidosis

    Science.gov (United States)

    ... this disorder. Alternative Names Renal tubular acidosis - distal; Renal tubular acidosis type I; Type I RTA; RTA - distal; Classical RTA Images Kidney anatomy Kidney - blood and urine flow References Bose A, Monk RD, Bushinsky DA. Kidney ...

  6. Ultrahigh-speed, high-sensitivity color camera with 300,000-pixel single CCD

    Science.gov (United States)

    Kitamura, K.; Arai, T.; Yonai, J.; Hayashida, T.; Ohtake, H.; Kurita, T.; Tanioka, K.; Maruyama, H.; Namiki, J.; Yanagi, T.; Yoshida, T.; van Kuijk, H.; Bosiers, Jan T.; Etoh, T. G.

    2007-01-01

    We have developed an ultrahigh-speed, high-sensitivity portable color camera with a new 300,000-pixel single CCD. The 300,000-pixel CCD, which has four times the number of pixels of our initial model, was developed by seamlessly joining two 150,000-pixel CCDs. A green-red-green-blue (GRGB) Bayer filter is used to realize a color camera with the single-chip CCD. The camera is capable of ultrahigh-speed video recording at up to 1,000,000 frames/sec, and small enough to be handheld. We also developed a technology for dividing the CCD output signal to enable parallel, highspeed readout and recording in external memory; this makes possible long, continuous shots up to 1,000 frames/second. As a result of an experiment, video footage was imaged at an athletics meet. Because of high-speed shooting, even detailed movements of athletes' muscles were captured. This camera can capture clear slow-motion videos, so it enables previously impossible live footage to be imaged for various TV broadcasting programs.

  7. A tilted fiber-optic plate coupled CCD detector for high resolution neutron imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jongyul; Cho, Gyuseong [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Kim, Jongyul; Hwy, Limchang; Kim, Taejoo; Lee, Kyehong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Seungwook [Pusan National Univ., Pusan (Korea, Republic of)

    2013-05-15

    One of these efforts is that a tilted scintillator geometry and lens coupled CCD detector for neutron imaging system were used to improve spatial resolution in one dimension. The increased spatial resolution in one dimension was applied to fuel cell study. However, a lens coupled CCD detector has lower sensitivity than a fiber-optic plate coupled CCD detector due to light loss. In this research, a tilted detector using fiber-optic plate coupled CCD detector was developed to improve resolution and sensitivity. In addition, a tilted detector can prevent an image sensor from direct radiation damage. Neutron imaging has been used for fuel cell study, lithium ion battery study, and many scientific applications. High quality neutron imaging is demanded for more detailed studies of applications, and spatial resolution should be considered to get high quality neutron imaging. Therefore, there were many efforts to improve spatial resolution.

  8. Head-mounted display for use in functional endoscopic sinus surgery

    Science.gov (United States)

    Wong, Brian J.; Lee, Jon P.; Dugan, F. Markoe; MacArthur, Carol J.

    1995-05-01

    Since the introduction of functional endoscopic sinus surgery (FESS), the procedure has undergone rapid change with evolution keeping pace with technological advances. The advent of low cost charge coupled device 9CCD) cameras revolutionized the practice and instruction of FESS. Video-based FESS has allowed for documentation of the surgical procedure as well as interactive instruction during surgery. Presently, the technical requirements of video-based FESS include the addition of one or more television monitors positioned strategically in the operating room. Thought video monitors have greatly enhanced surgical endoscopy by re- involving nurses and assistants in the actual mechanics of surgery, video monitors require the operating surgeon to be focused on the screen instead of the patient. In this study, we describe the use of a new low-cost liquid crystal display (LCD) based device that functions as a monitor but is mounted on the head on a visor (PT-O1, O1 Products, Westlake Village, CA). This study illustrates the application of these HMD devices to FESS operations. The same surgeon performed the operation in each patient. In one nasal fossa, surgery was performed using conventional video FESS methods. The contralateral side was operated on while wearing the head mounted video display. The device had adequate resolution for the purposes of FESS. No adverse effects were noted intraoperatively. The results on the patients ipsalateral and contralateral sides were similar. The visor did eliminated significant torsion of the surgeon's neck during the operation, while at the same time permitted simultaneous viewing of both the patient and the intranasal surgical field.

  9. Calibration of the CCD photonic measuring system for railway inspection

    Science.gov (United States)

    Popov, D. V.; Ryabichenko, R. B.; Krivosheina, E. A.

    2005-08-01

    Increasing of traffic speed is the most important task in Moscow Metro. Requirements for traffic safety grow up simultaneously with the speed increasing. Currently for track inspection in Moscow Metro is used track measurement car has built in 1954. The main drawbacks of this system are absence of automated data processing and low accuracy. Non-contact photonic measurement system (KSIR) is developed for solving this problem. New track inspection car will be built in several months. This car will use two different track inspection systems and car locating subsystem based on track circuit counting. The KSIR consists of four subsystems: rail wear, height and track gauge measurement (BFSM); rail slump measurement (FIP); contact rail measurement (FKR); speed, level and car locating (USI). Currently new subsystem for wheel flange wear (IRK) is developed. The KSIR carry out measurements in real-time mode. The BFSM subsystem contains 4 matrix CCD cameras and 4 infrared stripe illuminators. The FIP subsystem contains 4 line CCD cameras and 4 spot illuminators. The FKR subsystem contains 2 matrix CCD cameras and 2 stripe illuminators. The IRK subsystem contains 2 CCD cameras and 2 stripe illuminators. Each system calibration was carried out for their adjustment. On the first step KSIR obtains data from photonic sensors which is valued in internal measurement units. Due to the calibration on the second step non-contact system converts the data to metric measurement system.

  10. Distal protection in cardiovascular medicine: current status.

    Science.gov (United States)

    Ali, Onn Akbar; Bhindi, Ravinay; McMahon, Aisling C; Brieger, David; Kritharides, Leonard; Lowe, Harry C

    2006-08-01

    Iatrogenic and spontaneous downstream microembolization of atheromatous material is increasingly recognized as a source of cardiovascular morbidity and mortality. Devising ways of reducing this distal embolization using a variety of mechanical means--distal protection--is currently under intense and diverse investigation. This review therefore summarizes the present status of distal protection. It examines the problem of distal embolization, describes the available distal protection devices, reviews those areas of cardiovascular medicine where distal protection devices are being investigated, and discusses potential future developments.

  11. Digital Printing Quality Detection and Analysis Technology Based on CCD

    Science.gov (United States)

    He, Ming; Zheng, Liping

    2017-12-01

    With the help of CCD digital printing quality detection and analysis technology, it can carry out rapid evaluation and objective detection of printing quality, and can play a certain control effect on printing quality. It can be said CDD digital printing quality testing and analysis of the rational application of technology, its digital printing and printing materials for a variety of printing equipments to improve the quality of a very positive role. In this paper, we do an in-depth study and discussion based on the CCD digital print quality testing and analysis technology.

  12. On-ground and in-orbit characterisation plan for the PLATO CCD normal cameras

    Science.gov (United States)

    Gow, J. P. D.; Walton, D.; Smith, A.; Hailey, M.; Curry, P.; Kennedy, T.

    2017-11-01

    PLAnetary Transits and Ocillations (PLATO) is the third European Space Agency (ESA) medium class mission in ESA's cosmic vision programme due for launch in 2026. PLATO will carry out high precision un-interrupted photometric monitoring in the visible band of large samples of bright solar-type stars. The primary mission goal is to detect and characterise terrestrial exoplanets and their systems with emphasis on planets orbiting in the habitable zone, this will be achieved using light curves to detect planetary transits. PLATO uses a novel multi- instrument concept consisting of 26 small wide field cameras The 26 cameras are made up of a telescope optical unit, four Teledyne e2v CCD270s mounted on a focal plane array and connected to a set of Front End Electronics (FEE) which provide CCD control and readout. There are 2 fast cameras with high read-out cadence (2.5 s) for magnitude ~ 4-8 stars, being developed by the German Aerospace Centre and 24 normal (N) cameras with a cadence of 25 s to monitor stars with a magnitude greater than 8. The N-FEEs are being developed at University College London's Mullard Space Science Laboratory (MSSL) and will be characterised along with the associated CCDs. The CCDs and N-FEEs will undergo rigorous on-ground characterisation and the performance of the CCDs will continue to be monitored in-orbit. This paper discusses the initial development of the experimental arrangement, test procedures and current status of the N-FEE. The parameters explored will include gain, quantum efficiency, pixel response non-uniformity, dark current and Charge Transfer Inefficiency (CTI). The current in-orbit characterisation plan is also discussed which will enable the performance of the CCDs and their associated N-FEE to be monitored during the mission, this will include measurements of CTI giving an indication of the impact of radiation damage in the CCDs.

  13. Experience in CCD Photometry at the Tartu Observatory

    Directory of Open Access Journals (Sweden)

    Tuvikene T.

    2003-12-01

    Full Text Available We give overview of the CCD instrumentation and data reduction techniques used at the Tartu Observatory. The first results from photometric observations of the peculiar variable V838 Mon are presented.

  14. Application of X-ray CCD camera in X-ray spot diagnosis of rod-pinch diode

    International Nuclear Information System (INIS)

    Song Yan; Zhou Ming; Song Guzhou; Ma Jiming; Duan Baojun; Han Changcai; Yao Zhiming

    2015-01-01

    The pinhole imaging technique is widely used in the measurement of X-ray spot of rod-pinch diode. The X-ray CCD camera, which was composed of film, fiber optic taper and CCD camera, was employed to replace the imaging system based on scintillator, lens and CCD camera in the diagnosis of X-ray spot. The resolution of the X-ray CCD camera was studied. The resolution is restricted by the film and is 5 lp/mm in the test with Pb resolution chart. The frequency is 1.5 lp/mm when the MTF is 0.5 in the test with edge image. The resolution tests indicate that the X-ray CCD camera can meet the requirement of the diagnosis of X-ray spot whose scale is about 1.5 mm when the pinhole imaging magnification is 0.5. At last, the image of X-ray spot was gained and the restoration was implemented in the diagnosis of X-ray spot of rod-pinch diode. (authors)

  15. Optoelectronic Mounting Structure

    Science.gov (United States)

    Anderson, Gene R.; Armendariz, Marcelino G.; Baca, Johnny R. F.; Bryan, Robert P.; Carson, Richard F.; Chu, Dahwey; Duckett, III, Edwin B.; McCormick, Frederick B.; Peterson, David W.; Peterson, Gary D.; Reber, Cathleen A.; Reysen, Bill H.

    2004-10-05

    An optoelectronic mounting structure is provided that may be used in conjunction with an optical transmitter, receiver or transceiver module. The mounting structure may be a flexible printed circuit board. Thermal vias or heat pipes in the head region may transmit heat from the mounting structure to the heat spreader. The heat spreader may provide mechanical rigidity or stiffness to the heat region. In another embodiment, an electrical contact and ground plane may pass along a surface of the head region so as to provide an electrical contact path to the optoelectronic devices and limit electromagnetic interference. In yet another embodiment, a window may be formed in the head region of the mounting structure so as to provide access to the heat spreader. Optoelectronic devices may be adapted to the heat spreader in such a manner that the devices are accessible through the window in the mounting structure.

  16. A GRAPH READER USING A CCD IMAGE SENSOR

    African Journals Online (AJOL)

    2008-01-18

    Jan 18, 2008 ... using a stepper motor controlled by a software program in a ... Keywords: CCD sensor, microcontrollen stepper motor and microcomputer. 1. ... commercial applications (Awcock and ... on-chip amplifier, one pixel at a tirtjie.

  17. C.C.D. readout of a picosecond streak camera with an intensified C.C.D

    International Nuclear Information System (INIS)

    Lemonier, M.; Richard, J.C.; Cavailler, C.; Mens, A.; Raze, G.

    1984-08-01

    This paper deals with a digital streak camera readout device. The device consists in a low light level television camera made of a solid state C.C.D. array coupled to an image intensifier associated to a video-digitizer coupled to a micro-computer system. The streak camera images are picked-up as a video signal, digitized and stored. This system allows the fast recording and the automatic processing of the data provided by the streak tube

  18. [New anterolateral approach of distal femur for treatment of distal femoral fractures].

    Science.gov (United States)

    Zhang, Bin; Dai, Min; Zou, Fan; Luo, Song; Li, Binhua; Qiu, Ping; Nie, Tao

    2013-11-01

    To assess the effectiveness of the new anterolateral approach of the distal femur for the treatment of distal femoral fractures. Between July 2007 and December 2009, 58 patients with distal femoral fractures were treated by new anterolateral approach of the distal femur in 28 patients (new approach group) and by conventional approach in 30 patients (conventional approach group). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, disease duration, complication, or preoperative intervention (P > 0.05). The operation time, intraoperative blood loss, intraoperative fluoroscopy frequency, hospitalization days, and Hospital for Special Surgery (HSS) score of knee were recorded. Operation was successfully completed in all patients of 2 groups, and healing of incision by first intention was obtained; no vascular and nerves injuries occurred. The operation time and intraoperative fluoroscopy frequency of new approach group were significantly less than those of conventional approach group (P 0.05). All patients were followed up 12-36 months (mean, 19.8 months). Bone union was shown on X-ray films; the fracture healing time was (12.62 +/- 2.34) weeks in the new approach group and was (13.78 +/- 1.94) weeks in the conventional approach group, showing no significant difference (t=2.78, P=0.10). The knee HSS score at last follow-up was 94.4 +/- 4.2 in the new approach group, and was 89.2 +/- 6.0 in the conventional approach group, showing significant difference between 2 groups (t=3.85, P=0.00). New anterolateral approach of the distal femur for distal femoral fractures has the advantages of exposure plenitude, minimal tissue trauma, and early function rehabilitation training so as to enhance the function recovery of knee joint.

  19. First-light instrument for the 3.6-m Devasthal Optical Telescope: 4Kx4K CCD Imager

    Science.gov (United States)

    Pandey, Shashi Bhushan; Yadav, Rama Kant Singh; Nanjappa, Nandish; Yadav, Shobhit; Reddy, Bheemireddy Krishna; Sahu, Sanjit; Srinivasan, Ramaiyengar

    2018-04-01

    As a part of in-house instrument developmental activity at ARIES, the 4Kx4K CCD Imager is designed and developed as a first-light instrument for the axial port of the 3.6-m Devasthal Optical Telescope (DOT). The f/9 beam of the telescope having a plate-scale of 6.4"/mm is utilized to conduct deeper photom-etry within the central 10' field of view. The pixel size of the blue-enhanced liquid nitrogen cooled STA4150 4Kx4K CCD chip is 15 μm, with options to select gain and speed values to utilize the dynamic range. Using the Imager, it is planned to image the central 6.5'x6.5' field of view of the telescope for various science goals by getting deeper images in several broad-band filters for point sources and objects with low surface brightness. The fully assembled Imager along with automated filter wheels having Bessel UBV RI and SDSS ugriz filters was tested in late 2015 at the axial port of the 3.6-m DOT. This instrument was finally mounted at the axial port of the 3.6-m DOT on 30 March 2016 when the telescope was technically activated jointly by the Prime Ministers of India and Belgium. It is expected to serve as a general purpose multi-band deep imaging instrument for a variety of science goals including studies of cosmic transients, active galaxies, star clusters and optical monitoring of X-ray sources discovered by the newly launched Indian space-mission called ASTROSAT, and follow-up of radio bright objects discovered by the Giant Meterwave Radio Telescope.

  20. In-flight characterization of the HETE soft X-ray CCD cameras

    International Nuclear Information System (INIS)

    Prigozhin, G.; Villasenor, J.; Vanderspek, R.; Doty, J.; Crew, G.; Ricker, G.; Jernigan, G.

    2003-01-01

    We have developed a set of software tools that allow to monitor the performance of the flight X-ray CCD cameras as soon as data arrive at MIT. An emission line at 5.9 keV from the on-board Fe-55 radioactive calibration source is clearly visible in the spectra and provides the means to measure the gain and the noise for each observation in each of the 4 CCD chips in operation. Both parameters can change with time, depending on the phase of the moon and the amount of light leaking into the system. Time vs. position scatter plots were found to be an extremely powerful tool in understanding of the device performance. They illustrate the evolution of the light leaks produced by the dark Earth at the beginning and the end of each orbit. With a bright X-ray source in the field of view the shadow of the mask projected on the surface of the CCD clearly shows the motions of the spacecraft

  1. Protein diffraction experiments with Atlas CCD detector

    Czech Academy of Sciences Publication Activity Database

    Dohnálek, Jan; Kovaľ, Tomáš; Dušek, Michal

    2008-01-01

    Roč. 64, Suppl. - abstracts (2008), C192 ISSN 0108-7673. [Congress of the International Union of Crystallography (IUCr) /21./. 23.08.2008-31.08.2008, Osaka] Institutional research plan: CEZ:AV0Z10100521 Keywords : x-ray data collection * CCD detectors * protein crystallography applications Subject RIV: BM - Solid Matter Physics ; Magnetism

  2. Discussion on the fusing methods for HR and CCD images of CBERS

    International Nuclear Information System (INIS)

    Gao Zhangsheng; Zhao Yingjun

    2010-01-01

    CBERS-02B multi-spectral CCD data are different from HR panchromatic data in resolution, which causes difficulty in image fusion. With the method of Pansharping, HPF, Brovey transform, IHS transform, principal component transform, Gram Schmidt (GS) transform and wavelet transform, the authors have tested the fusion methods for CCD data and HR data of CBERS, and the fusion results are discussed and evaluated qualitatively and quantitatively. (authors)

  3. Entirely saturated unilateral smear of laser spot in CCD

    International Nuclear Information System (INIS)

    Zhang Zhen; Zhou Menglian; Zhang Jianmin; Lin Xinwei

    2013-01-01

    In the video of linear CCD camera being irradiated by 532 nm CW laser, the entirely saturated unilateral smear of laser spot was found. The smear area does not represent the distribution of laser. Since this smear lies merely in one side of laser spot, it can not be induced by light leaking or carriers blooming, and it may be induced by charge transfer loss. However, the feature that the smear area is entirely saturated can not be explained by the current constant model of charge transfer inefficiency. Based on the inner structure and operating principle of buried channel CCD, a new model of charge transfer inefficiency that varies with charge quantity is proposed, which can explain the entirely saturated unilateral smear of laser spot. (authors)

  4. CCD developed for scientific application by Hamamatsu

    CERN Document Server

    Miyaguchi, K; Dezaki, J; Yamamoto, K

    1999-01-01

    We have developed CCDs for scientific applications that feature a low readout noise of less than 5 e-rms and low dark current of 10-25 pA/cm sup 2 at room temperature. CCDs with these characteristics will prove extremely useful in applications such as spectroscopic measurement and dental radiography. In addition, a large-area CCD of 2kx4k pixels and 15 mu m square pixel size has recently been completed for optical use in astronomical observations. Applications to X-ray astronomy require the most challenging device performance in terms of deep depletion, high CTE, and focal plane size, among others. An abuttable X-ray CCD, having 1024x1024 pixels and 24 mu m square pixel size, is to be installed in an international space station (ISS). We are now striving to achieve the lowest usable cooling temperature by means of a built-in TEC with limited power consumption. Details on the development status are described in this report. We would also like to present our future plans for a large active area and deep depleti...

  5. High performance CCD camera system for digitalisation of 2D DIGE gels.

    Science.gov (United States)

    Strijkstra, Annemieke; Trautwein, Kathleen; Roesler, Stefan; Feenders, Christoph; Danzer, Daniel; Riemenschneider, Udo; Blasius, Bernd; Rabus, Ralf

    2016-07-01

    An essential step in 2D DIGE-based analysis of differential proteome profiles is the accurate and sensitive digitalisation of 2D DIGE gels. The performance progress of commercially available charge-coupled device (CCD) camera-based systems combined with light emitting diodes (LED) opens up a new possibility for this type of digitalisation. Here, we assessed the performance of a CCD camera system (Intas Advanced 2D Imager) as alternative to a traditionally employed, high-end laser scanner system (Typhoon 9400) for digitalisation of differential protein profiles from three different environmental bacteria. Overall, the performance of the CCD camera system was comparable to the laser scanner, as evident from very similar protein abundance changes (irrespective of spot position and volume), as well as from linear range and limit of detection. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Technical challenges and recent progress in CCD imagers

    International Nuclear Information System (INIS)

    Bosiers, Jan T.; Peters, Inge M.; Draijer, Cees; Theuwissen, Albert

    2006-01-01

    This paper gives a review of the performance of charge-coupled device (CCD) imagers for use in consumer, professional and scientific applications. An overview of recent developments and the current state-of-the-art are presented. An extensive list of references is included

  7. CCD [charge-coupled device] sensors in synchrotron x-ray detectors

    International Nuclear Information System (INIS)

    Strauss, M.G.; Naday, I.; Sherman, I.S.; Kraimer, M.R.; Westbrook, E.M.; Zaluzec, N.J.

    1987-01-01

    The intense photon flux from advanced synchrotron light sources, such as the 7-GeV synchrotron being designed at Argonne, require integrating-type detectors. Charge-coupled devices (CCDs) are well suited as synchrotron x-ray detectors. When irradiated indirectly via a phosphor followed by reducing optics, diffraction patterns of 100 cm 2 can be imaged on a 2 cm 2 CCD. With a conversion efficiency of ∼1 CCD electron/x-ray photon, a peak saturation capacity of >10 6 x rays can be obtained. A programmable CCD controller operating at a clock frequency of 20 MHz has been developed. The readout rate is 5 x 10 6 pixels/s and the shift rate in the parallel registers is 10 6 lines/s. The test detector was evaluated in two experiments. In protein crystallography diffraction patterns have been obtained from a lysozyme crystal using a conventional rotating anode x-ray generator. Based on these results we expect to obtain at a synchrotron diffraction images at the rate of ∼1 frame/s or a complete 3-dimensional data set from a single crystal in ∼2 min. 16 refs., 16 figs., 2 tabs

  8. High-performance visible/UV CCD focal plane technology for spacebased applications

    Science.gov (United States)

    Burke, B. E.; Mountain, R. W.; Gregory, J. A.; Huang, J. C. M.; Cooper, M. J.; Savoye, E. D.; Kosicki, B. B.

    1993-01-01

    We describe recent technology developments aimed at large CCD imagers for space based applications in the visible and UV. Some of the principal areas of effort include work on reducing device degradation in the natural space-radiation environment, improvements in quantum efficiency in the visible and UV, and larger-device formats. One of the most serious hazards for space based CCD's operating at low signal levels is the displacement damage resulting from bombardment by energetic protons. Such damage degrades charge-transfer efficiency and increases dark current. We have achieved improved hardness to proton-induced displacement damage by selective ion implants into the CCD channel and by reduced temperature of operation. To attain high quantum efficiency across the visible and UV we have developed a technology for back-illuminated CCD's. With suitable antireflection (AR) coatings such devices have quantum efficiencies near 90 percent in the 500-700-nm band. In the UV band from 200 to 400 nm, where it is difficult to find coatings that are sufficiently transparent and can provide good matching to the high refractive index of silicon, we have been able to substantially increase the quantum efficiency using a thin film of HfO2 as an AR coating. These technology efforts were applied to a 420 x 420-pixel frame-transfer imager, and future work will be extended to a 1024 x 1024-pixel device now under development.

  9. Intensified CCD for ultrafast diagnostics

    International Nuclear Information System (INIS)

    Cheng, J.; Tripp, G.; Coleman, L.

    1978-01-01

    Many of the present laser fusion diagnostics are recorded on either ultrafast streak cameras or on oscilloscopes. For those experiments in which a large volume of data is accumulated, direct computer processing of the information becomes important. We describe an approach which uses a RCA 52501 back-thinned CCD sensor to obtain direct electron readouts for both the streak camera and the CRT. Performance of the 100 GHz streak camera and the 4 GHz CRT are presented. Design parameters and computer interfacing for both systems are described in detail

  10. Rethinking CCD's Significance in Estimating Late Neogene Whole Ocean Carbonate Budget

    Science.gov (United States)

    Si, W.; Rosenthal, Y.

    2017-12-01

    The global averaged calcite compensation depth (CCD) record is conventionally used to reconstruct two correlatable parameters of the carbonate system - the alkalinity budget of the ocean and/or the saturation state of the ocean. Accordingly, the available CCD reconstructions have been interpreted to suggest either relative stable (Pearson and Palmer, 2000) or increased alkalinity of the ocean over the past 15 Ma (Tyrrell and Zeebe, 2004; Pälike et al., 2012). However, CCD alone is insufficient to constrain the carbonate system because the weathering flux of alkalinity into the ocean is not only balanced by CaCO3 dissolution on the seafloor but also by the biologic production in the euphotic zone and, the CCD records cannot be readily interpreted as changes in either process. Here, we present evidence of the co-evolution of surface CaCO3 production and deepsea dissolution through the late Neogene. By examining separately the mass accumulation rates (MAR) of coccoliths, planktonic foraminifera, and quantifying dissolution (using a proxy revised from Broecker et al., 1999) in seventeen deepsea cores from multiple depth-transects, we find that 1) MAR of dissolution-resistant coccoliths was substantially higher in the mid Miocene and declining on a global scale towards the present; 2) unlike coccoliths, MAR of planktonic foraminifera, shows no apparent secular trend through that time; 3) the revised dissolution index, shows significantly improved preservation of planktonic foraminiferal shells over that time, particularly at intermediate water depth and exhibits close association between changes in preservation with key climatic events. Our new records have two immediate implications. First, the substantially weakened pelagic biogenic carbonate production from mid Miocene to present alone could account for the improved preservation of deepsea carbonates without calling for a scenario of increased weathering input. Second, with the constrain of global averaged CCD

  11. Measurement of phase function of aerosol at different altitudes by CCD Lidar

    Science.gov (United States)

    Sun, Peiyu; Yuan, Ke'e.; Yang, Jie; Hu, Shunxing

    2018-02-01

    The aerosols near the ground are closely related to human health and climate change, the study on which has important significance. As we all know, the aerosol is inhomogeneous at different altitudes, of which the phase function is also different. In order to simplify the retrieval algorithm, it is usually assumed that the aerosol is uniform at different altitudes, which will bring measurement error. In this work, an experimental approach is demonstrated to measure the scattering phase function of atmospheric aerosol particles at different heights by CCD lidar system, which could solve the problem of the traditional CCD lidar system in assumption of phase function. The phase functions obtained by the new experimental approach are used to retrieve the aerosol extinction coefficient profiles. By comparison of the aerosol extinction coefficient retrieved by Mie-scattering aerosol lidar and CCD lidar at night, the reliability of new experimental approach is verified.

  12. Design principles and applications of a cooled CCD camera for electron microscopy.

    Science.gov (United States)

    Faruqi, A R

    1998-01-01

    Cooled CCD cameras offer a number of advantages in recording electron microscope images with CCDs rather than film which include: immediate availability of the image in a digital format suitable for further computer processing, high dynamic range, excellent linearity and a high detective quantum efficiency for recording electrons. In one important respect however, film has superior properties: the spatial resolution of CCD detectors tested so far (in terms of point spread function or modulation transfer function) are inferior to film and a great deal of our effort has been spent in designing detectors with improved spatial resolution. Various instrumental contributions to spatial resolution have been analysed and in this paper we discuss the contribution of the phosphor-fibre optics system in this measurement. We have evaluated the performance of a number of detector components and parameters, e.g. different phosphors (and a scintillator), optical coupling with lens or fibre optics with various demagnification factors, to improve the detector performance. The camera described in this paper, which is based on this analysis, uses a tapered fibre optics coupling between the phosphor and the CCD and is installed on a Philips CM12 electron microscope equipped to perform cryo-microscopy. The main use of the camera so far has been in recording electron diffraction patterns from two dimensional crystals of bacteriorhodopsin--from wild type and from different trapped states during the photocycle. As one example of the type of data obtained with the CCD camera a two dimensional Fourier projection map from the trapped O-state is also included. With faster computers, it will soon be possible to undertake this type of work on an on-line basis. Also, with improvements in detector size and resolution, CCD detectors, already ideal for diffraction, will be able to compete with film in the recording of high resolution images.

  13. Shoulder-Mounted Robot for MRI-guided arthrography: Accuracy and mounting study.

    Science.gov (United States)

    Monfaredi, R; Wilson, E; Sze, R; Sharma, K; Azizi, B; Iordachita, I; Cleary, K

    2015-08-01

    A new version of our compact and lightweight patient-mounted MRI-compatible 4 degree-of-freedom (DOF) robot for MRI-guided arthrography procedures is introduced. This robot could convert the traditional two-stage arthrography procedure (fluoroscopy-guided needle insertion followed by a diagnostic MRI scan) to a one-stage procedure, all in the MRI suite. The results of a recent accuracy study are reported. A new mounting technique is proposed and the mounting stability is investigated using optical and electromagnetic tracking on an anthropomorphic phantom. Five volunteer subjects including 2 radiologists were asked to conduct needle insertion in 4 different random positions and orientations within the robot's workspace and the displacement of the base of the robot was investigated during robot motion and needle insertion. Experimental results show that the proposed mounting method is stable and promising for clinical application.

  14. Real-time tricolor phase measuring profilometry based on CCD sensitivity calibration

    Science.gov (United States)

    Zhu, Lin; Cao, Yiping; He, Dawu; Chen, Cheng

    2017-02-01

    A real-time tricolor phase measuring profilometry (RTPMP) based on charge coupled device (CCD) sensitivity calibration is proposed. Only one colour fringe pattern whose red (R), green (G) and blue (B) components are, respectively, coded as three sinusoidal phase-shifting gratings with an equivalent shifting phase of 2π/3 is needed and sent to an appointed flash memory on a specialized digital light projector (SDLP). A specialized time-division multiplexing timing sequence actively controls the SDLP to project the fringe patterns in R, G and B channels sequentially onto the measured object in one over seventy-two of a second and meanwhile actively controls a high frame rate monochrome CCD camera to capture the corresponding deformed patterns synchronously with the SDLP. So the sufficient information for reconstructing the three-dimensional (3D) shape in one over twenty-four of a second is obtained. Due to the different spectral sensitivity of the CCD camera to RGB lights, the captured deformed patterns from R, G and B channels cannot share the same peak and valley, which will lead to lower accuracy or even failing to reconstruct the 3D shape. So a deformed pattern amending method based on CCD sensitivity calibration is developed to guarantee the accurate 3D reconstruction. The experimental results verify the feasibility of the proposed RTPMP method. The proposed RTPMP method can obtain the 3D shape at over the video frame rate of 24 frames per second, avoid the colour crosstalk completely and be effective for measuring real-time changing object.

  15. Development of online cable eccentricity detection system based on X-ray CCD

    International Nuclear Information System (INIS)

    Chen Jianzhen; Li Bin; Wei Kaixia; Guo Lanying; Qu Guopu

    2008-01-01

    An improved technology of online cable eccentricity detection, based on X-ray CCD, greatly improves the measuring precision and the responding speed. The theory of eccentricity measuring based on X-ray CCD, and the structure of an apparatus are described. The apparatus is composed of scanning drive subsystem, X-ray generation components, data acquiring subsystem and high performance computer system. The measuring results are also presented. The features of this cable eccentricity detection technology are compared with the features of other technologies. (authors)

  16. Development of a Portable 3CCD Camera System for Multispectral Imaging of Biological Samples

    Science.gov (United States)

    Lee, Hoyoung; Park, Soo Hyun; Noh, Sang Ha; Lim, Jongguk; Kim, Moon S.

    2014-01-01

    Recent studies have suggested the need for imaging devices capable of multispectral imaging beyond the visible region, to allow for quality and safety evaluations of agricultural commodities. Conventional multispectral imaging devices lack flexibility in spectral waveband selectivity for such applications. In this paper, a recently developed portable 3CCD camera with significant improvements over existing imaging devices is presented. A beam-splitter prism assembly for 3CCD was designed to accommodate three interference filters that can be easily changed for application-specific multispectral waveband selection in the 400 to 1000 nm region. We also designed and integrated electronic components on printed circuit boards with firmware programming, enabling parallel processing, synchronization, and independent control of the three CCD sensors, to ensure the transfer of data without significant delay or data loss due to buffering. The system can stream 30 frames (3-waveband images in each frame) per second. The potential utility of the 3CCD camera system was demonstrated in the laboratory for detecting defect spots on apples. PMID:25350510

  17. The OCA CCD Camera Controller

    Science.gov (United States)

    1996-01-01

    multi CCD arrays for wide field telescopes with an array of 8x8 1K CCDs in use at Las Campanas Observatory in Chile . The same group is also involved...Verify key EPROM -292H VIH . VIH Program security bitl 1 29AH . VPP Program security’ bit 2 *. .298H -Vpp Verify security bits - 9HVIH ViI NOTE: 1...Pulsed from V.. to VIL and returned to VIH . EPROM PROGRAMMING AND VERIFICATION ..t= 21’C to-+27 ’rC:-VCC= 5V ±10%VS3 = OV. SYMBOL I .-- PARAMETER MIN MAX

  18. The design and development of low- and high-voltage ASICs for space-borne CCD cameras

    Science.gov (United States)

    Waltham, N.; Morrissey, Q.; Clapp, M.; Bell, S.; Jones, L.; Torbet, M.

    2017-12-01

    The CCD remains the pre-eminent visible and UV wavelength image sensor in space science, Earth and planetary remote sensing. However, the design of space-qualified CCD readout electronics is a significant challenge with requirements for low-volume, low-mass, low-power, high-reliability and tolerance to space radiation. Space-qualified components are frequently unavailable and up-screened commercial components seldom meet project or international space agency requirements. In this paper, we describe an alternative approach of designing and space-qualifying a series of low- and high-voltage mixed-signal application-specific integrated circuits (ASICs), the ongoing development of two low-voltage ASICs with successful flight heritage, and two new high-voltage designs. A challenging sub-system of any CCD camera is the video processing and digitisation electronics. We describe recent developments to improve performance and tolerance to radiation-induced single event latchup of a CCD video processing ASIC originally developed for NASA's Solar Terrestrial Relations Observatory and Solar Dynamics Observatory. We also describe a programme to develop two high-voltage ASICs to address the challenges presented with generating a CCD's bias voltages and drive clocks. A 0.35 μm, 50 V tolerant, CMOS process has been used to combine standard low-voltage 3.3 V transistors with high-voltage 50 V diffused MOSFET transistors that enable output buffers to drive CCD bias drains, gates and clock electrodes directly. We describe a CCD bias voltage generator ASIC that provides 24 independent and programmable 0-32 V outputs. Each channel incorporates a 10-bit digital-to-analogue converter, provides current drive of up to 20 mA into loads of 10 μF, and includes current-limiting and short-circuit protection. An on-chip telemetry system with a 12-bit analogue-to-digital converter enables the outputs and multiple off-chip camera voltages to be monitored. The ASIC can drive one or more CCDs and

  19. Arthroplasty of the distal ulna distal in managing patients with post-traumatic disorders of the distal radioulnar joint: measurement of quality of life

    Directory of Open Access Journals (Sweden)

    Marcio Aurélio Aita

    2015-12-01

    Full Text Available ABSTRACT OBJECTIVE: To measure the quality of life and clinical-functional results from patients diagnosed with osteoarthrosis of the distal radioulnar joint who underwent surgical treatment using the technique of total arthroplasty of the ulna, with a total or partial Ascension(r prosthesis of the distal ulna. METHODS: Ten patients were evaluated after 12 months of follow-up subsequent to total or partial arthroplasty of the distal ulna. All of them presented post-traumatic osteoarthrosis and/or chronic symptomatic instability of the distal radioulnar joint. The study was prospective. Seven patients had previously undergone wrist procedures (two cases with Darrach, three with Sauvé-Kapandji and two with ligament reconstruction of the fibrocartilage complex and three presented fractures of the distal ulna that evolved with pain, instability and osteoarthrosis of the distal radioulnar joint. The following were assessed: quality of life (DASH scale; percentage degree of palm grip strength (kgf and pronosupination range of motion in relation to the unaffected side; pain (VAS; return to work; subjective evaluation of radiography; and complications. RESULTS: The patients presented a mean range of motion of 174.5° (normal side: 180°. Quality of life was analyzed by applying the DASH questionnaire and the mean value found was 5.9. The mean pain score using the VAS was 2.3. The mean degree of palm grip strength (kgf was 50.7, which represented 90.7% of the strength on the unaffected side. The complication rate was 10%: this patient presented slight dorsal instability of the ulna and persistent pain, and did not return to work. This patient is still being followed up in the outpatient clinic and occupational therapy sector, with little improvement. He does not wish to undergo a new procedure. The mean length of follow-up was 16.8 months, with a minimum of 10 and maximum of 36 months. CONCLUSION: This concept is subject to the test of time

  20. Micrometer and CCD measurements of double stars (Series 51

    Directory of Open Access Journals (Sweden)

    Popović G.M.

    1998-01-01

    Full Text Available 36 micrometric measurements of 20 double or multiple systems carried out with the Zeiss 65/1055 cm Refractor of Belgrade Observatory are communicated. Also 35 CCD measurements of 15 double or multiple systems are included.

  1. STIS-01 CCD Functional

    Science.gov (United States)

    Valenti, Jeff

    2001-07-01

    This activity measures the baseline performance and commandability of the CCD subsystem. Only primary amplifier D is used. Bias, Dark, and Flat Field exposures are taken in order to measure read noise, dark current, CTE, and gain. Numerous bias frames are taken to permit construction of "superbias" frames in which the effects of read noise have been rendered negligible. Dark exposures are made outside the SAA. Full frame and binned observations are made, with binning factors of 1x1 and 2x2. Finally, tungsten lamp exposures are taken through narrow slits to confirm the slit positions in the current database. All exposures are internals. This is a reincarnation of SM3A proposal 8502 with some unnecessary tests removed from the program.

  2. Two-dimensional spectrophotometry of planetary nebulae by CCD imaging

    International Nuclear Information System (INIS)

    Jacoby, G.H.; Africano, J.L.; Quigley, R.J.; Western Washington Univ., Bellingham, WA)

    1987-01-01

    The spatial distribution of the electron temperature and density and the ionic abundances of O(+), O(2+), N(+), and S(+) have been derived from CCD images of the planetary nebulae NGC 40 and NGC 6826 taken in the important emission lines of forbidden O II, forbidden O III, H-beta, forbidden N II, and forbidden S II. The steps required in the derivation of the absolute fluxes, line, ratios, and ionic abundances are outlined and then discussed in greater detail. The results show that the CCD imaging technique for two-dimensional spectrophotometry can effectively compete with classical spectrophotometry, providing the added benefits of complete spatial coverage at seeing-disk spatial resolution. The multiplexing in the spatial dimension, however, results in a loss of spectral information, since only one emission line is observed at any one time. 37 references

  3. Analysis of adjusting effects of mounting force on frequency conversion of mounted nonlinear optics.

    Science.gov (United States)

    Su, Ruifeng; Liu, Haitao; Liang, Yingchun; Lu, Lihua

    2014-01-10

    Motivated by the need to increase the second harmonic generation (SHG) efficiency of nonlinear optics with large apertures, a novel mounting configuration with active adjusting function on the SHG efficiency is proposed and mechanically and optically studied. The adjusting effects of the mounting force on the distortion and stress are analyzed by the finite element methods (FEM), as well as the contribution of the distortion and stress to the change in phase mismatch, and the SHG efficiency are theoretically stated. Further on, the SHG efficiency is calculated as a function of the mounting force. The changing trends of the distortion, stress, and the SHG efficiency with the varying mounting force are obtained, and the optimal ones are figured out. Moreover, the mechanism of the occurrence of the optimal values is studied and the adjusting strategy is put forward. Numerical results show the robust adjustment of the mounting force, as well as the effectiveness of the mounting configuration, in increasing the SHG efficiency.

  4. Robotic distal pancreatectomy versus conventional laparoscopic distal pancreatectomy: a comparative study for short-term outcomes.

    Science.gov (United States)

    Lai, Eric C H; Tang, Chung Ngai

    2015-09-01

    Robotic system has been increasingly used in pancreatectomy. However, the effectiveness of this method remains uncertain. This study compared the surgical outcomes between robot-assisted laparoscopic distal pancreatectomy and conventional laparoscopic distal pancreatectomy. During a 15-year period, 35 patients underwent minimally invasive approach of distal pancreatectomy in our center. Seventeen of these patients had robot-assisted laparoscopic approach, and the remaining 18 had conventional laparoscopic approach. Their operative parameters and perioperative outcomes were analyzed retrospectively in a prospective database. The mean operating time in the robotic group (221.4 min) was significantly longer than that in the laparoscopic group (173.6 min) (P = 0.026). Both robotic and conventional laparoscopic groups presented no significant difference in spleen-preservation rate (52.9% vs. 38.9%) (P = 0.505), operative blood loss (100.3 ml vs. 268.3 ml) (P = 0.29), overall morbidity rate (47.1% vs. 38.9%) (P = 0.73), and post-operative hospital stay (11.4 days vs. 14.2 days) (P = 0.46). Both groups also showed no perioperative mortality. Similar outcomes were observed in robotic distal pancreatectomy and conventional laparoscopic approach. However, robotic approach tended to have the advantages of less blood loss and shorter hospital stay. Further studies are necessary to determine the clinical position of robotic distal pancreatectomy.

  5. A fluorescent screen + CCD system for quality assurance of therapeutic scanned ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Takeshita, E., E-mail: eriuli@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Furukawa, T., E-mail: t_furu@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Inaniwa, T., E-mail: taku@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Sato, S., E-mail: shin_s@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Himukai, T., E-mail: himukai@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Shirai, T., E-mail: t_shirai@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan); Noda, K., E-mail: noda_k@nirs.go.jp [National Institute of Radiological Sciences, Chiba (Japan)

    2011-12-15

    A fluorescent screen + a charge coupled device (CCD) system were developed to verify the performance of scanned ion beams at the HIMAC. The fluorescent light from the screen is observed by the CCD camera. Two-dimensional fields, produced by the scanning process, i.e., the position and the size of the beam for each scan, represent of the important issues in scanning irradiation. In the developed system, the two-dimensional relative fluence and the flatness of the irradiation field were measured in a straightforward technique from the luminance distribution on the screen. The position and the size of the beams were obtained from centroid computation results of the brightness. By the good sensitivity and spatial resolution of the fluorescent screen + CCD system, the scanned ion beams were verified as the measurements at the HIMAC prototype scanning system.

  6. A fluorescent screen + CCD system for quality assurance of therapeutic scanned ion beams

    Science.gov (United States)

    Takeshita, E.; Furukawa, T.; Inaniwa, T.; Sato, S.; Himukai, T.; Shirai, T.; Noda, K.

    2011-12-01

    A fluorescent screen + a charge coupled device (CCD) system were developed to verify the performance of scanned ion beams at the HIMAC. The fluorescent light from the screen is observed by the CCD camera. Two-dimensional fields, produced by the scanning process, i.e., the position and the size of the beam for each scan, represent of the important issues in scanning irradiation. In the developed system, the two-dimensional relative fluence and the flatness of the irradiation field were measured in a straightforward technique from the luminance distribution on the screen. The position and the size of the beams were obtained from centroid computation results of the brightness. By the good sensitivity and spatial resolution of the fluorescent screen + CCD system, the scanned ion beams were verified as the measurements at the HIMAC prototype scanning system.

  7. SlCCD7 controls strigolactone biosynthesis, shoot branching and mycorrhiza-induced apocarotenoid formation in tomato.

    NARCIS (Netherlands)

    Vogel, J.T.; Walter, M.H.; Giavalisco, P.; Lytovchenko, A.; Kohlen, W.; Charnikhova, T.; Simkin, A.J.; Goulet, C.; Strack, D.; Bouwmeester, H.J.; Fernie, A.R.; Klee, H.J.

    2010-01-01

    The regulation of shoot branching is an essential determinant of plant architecture, integrating multiple external and internal signals. One of the signaling pathways regulating branching involves the MAX (more axillary branches) genes. Two of the genes within this pathway, MAX3/CCD7 and MAX4/CCD8,

  8. New low noise CCD cameras for Pi-of-the-Sky project

    Science.gov (United States)

    Kasprowicz, G.; Czyrkowski, H.; Dabrowski, R.; Dominik, W.; Mankiewicz, L.; Pozniak, K.; Romaniuk, R.; Sitek, P.; Sokolowski, M.; Sulej, R.; Uzycki, J.; Wrochna, G.

    2006-10-01

    Modern research trends require observation of fainter and fainter astronomical objects on large areas of the sky. This implies usage of systems with high temporal and optical resolution with computer based data acquisition and processing. Therefore Charge Coupled Devices (CCD) became so popular. They offer quick picture conversion with much better quality than film based technologies. This work is theoretical and practical study of the CCD based picture acquisition system. The system was optimized for "Pi of The Sky" project. But it can be adapted to another professional astronomical researches. The work includes issue of picture conversion, signal acquisition, data transfer and mechanical construction of the device.

  9. Numerical simulations and analyses of temperature control loop heat pipe for space CCD camera

    Science.gov (United States)

    Meng, Qingliang; Yang, Tao; Li, Chunlin

    2016-10-01

    As one of the key units of space CCD camera, the temperature range and stability of CCD components affect the image's indexes. Reasonable thermal design and robust thermal control devices are needed. One kind of temperature control loop heat pipe (TCLHP) is designed, which highly meets the thermal control requirements of CCD components. In order to study the dynamic behaviors of heat and mass transfer of TCLHP, particularly in the orbital flight case, a transient numerical model is developed by using the well-established empirical correlations for flow models within three dimensional thermal modeling. The temperature control principle and details of mathematical model are presented. The model is used to study operating state, flow and heat characteristics based upon the analyses of variations of temperature, pressure and quality under different operating modes and external heat flux variations. The results indicate that TCLHP can satisfy the thermal control requirements of CCD components well, and always ensure good temperature stability and uniformity. By comparison between flight data and simulated results, it is found that the model is to be accurate to within 1°C. The model can be better used for predicting and understanding the transient performance of TCLHP.

  10. CCD photometry of apparent dwarf galaxies in Fornax

    International Nuclear Information System (INIS)

    Phillipps, S.; Grimley, P.L.; Disney, M.J.; Cawson, M.G.M.; Kibblewhite, E.J.

    1986-01-01

    Blue and red CCD surface photometry of two apparent dwarf galaxies in the Fornax cluster region is presented. Luminosity profiles are derived and their form discussed. The fainter galaxy resembles an archetypal diffuse dwarf elliptical but the brighter of the pair is either an unusual red dwarf or a background galaxy in chance juxtaposition. (author)

  11. Mounting for ceramic scroll

    Science.gov (United States)

    Petty, Jack D.

    1993-01-01

    A mounting for a ceramic scroll on a metal engine block of a gas turbine engine includes a first ceramic ring and a pair of cross key connections between the first ceramic ring, the ceramic scroll, and the engine block. The cross key connections support the scroll on the engine block independent of relative radial thermal growth and for bodily movement toward an annular mounting shoulder on the engine. The scroll has an uninterrupted annular shoulder facing the mounting shoulder on the engine block. A second ceramic ring is captured between mounting shoulder and the uninterrupted shoulder on the scroll when the latter is bodily shifted toward the mouting shoulder to define a gas seal between the scroll and the engine block.

  12. Solar panel truss mounting systems and methods

    Energy Technology Data Exchange (ETDEWEB)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2016-06-28

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  13. Solar panel truss mounting systems and methods

    Energy Technology Data Exchange (ETDEWEB)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2018-01-30

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  14. Solar panel truss mounting systems and methods

    Science.gov (United States)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2015-10-20

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  15. The development of high-speed 100 fps CCD camera

    International Nuclear Information System (INIS)

    Hoffberg, M.; Laird, R.; Lenkzsus, F.; Liu, C.; Rodricks, B.

    1997-01-01

    This paper describes the development of a high-speed CCD digital camera system. The system has been designed to use CCDs from various manufacturers with minimal modifications. The first camera built on this design utilizes a Thomson 512 x 512 pixel CCD as its sensor, which is read out from two parallel outputs at a speed of 15 MHz/pixel/output. The data undergo correlated double sampling after which it is digitized into 12 bits. The throughput of the system translates into 60 MB/second, which is either stored directly in a PC or transferred to a custom-designed VXI module. The PC data acquisition version of the camera can collect sustained data in real time that is limited to the memory installed in the PC. The VXI version of the camera, also controlled by a PC, stores 512 MB of real-time data before it must be read out to the PC disk storage. The uncooled CCD can be used either with lenses for visible light imaging or with a phosphor screen for X-ray imaging. This camera has been tested with a phosphor screen coupled to a fiber-optic face plate for high-resolution, high-speed X-ray imaging. The camera is controlled through a custom event-driven user-friendly Windows package. The pixel clock speed can be changed from 1 to 15 MHz. The noise was measured to be 1.05 bits at a 13.3 MHz pixel clock. This paper will describe the electronics, software, and characterizations that have been performed using both visible and X-ray photons. (orig.)

  16. Application of the CCD Fabry-Perot Annular Summing Technique to Thermospheric O(1)D.

    Science.gov (United States)

    Coakley, Monica Marie

    1995-01-01

    This work will detail the verification of the advantages of the Fabry-Perot charge coupled device (CCD) annular summing technique, the development of the technique for analysis of daysky spectra, and the implications of the resulting spectra for neutral temperature and wind measurements in the daysky thermosphere. The daysky spectral feature of interest is the bright (1 kilo-Rayleigh) thermospheric (OI) emission at 6300 A which had been observed in the nightsky in order to determine winds and temperatures in the vicinity of the altitude of 250 km. In the daysky, the emission line sits on top of a bright Rayleigh scattered continuum background which significantly complicates the observation. With a triple etalon Fabry-Perot spectrometer, the continuum background can be reduced while maintaining high throughput and high resolution. The inclusion of a CCD camera results in significant savings in integration time over the two more standard scanning photomultiplier systems that have made the same wind and temperature measurements in the past. A comparable CCD system can experience an order of magnitude savings in integration time over a PMT system. Laboratory and field tests which address the advantages and limitations of both the Fabry-Perot CCD annular summing technique and the daysky CCD imaging are included in Chap. 2 and Chap. 3. With a sufficiently large throughput associated with the spectrometer and a CCD detector, rapid observations (~4 minute integrations) can be made. Extraction of the line width and line center from the daysky near-continuum background is complicated compared to the nightsky case, but possible. Methods of fitting the line are included in Chap. 4. The daysky O ^1D temperatures are consistent with a lower average emission height than predicted by models. The data and models are discussed in Chap. 5. Although some discrepancies exist between resulting temperatures and models, the observations indicate the potential for other direct measurements

  17. The head-mounted microscope.

    Science.gov (United States)

    Chen, Ting; Dailey, Seth H; Naze, Sawyer A; Jiang, Jack J

    2012-04-01

    Microsurgical equipment has greatly advanced since the inception of the microscope into the operating room. These advancements have allowed for superior surgical precision and better post-operative results. This study focuses on the use of the Leica HM500 head-mounted microscope for the operating phonosurgeon. The head-mounted microscope has an optical zoom from 2× to 9× and provides a working distance from 300 mm to 700 mm. The headpiece, with its articulated eyepieces, adjusts easily to head shape and circumference, and offers a focus function, which is either automatic or manually controlled. We performed five microlaryngoscopic operations utilizing the head-mounted microscope with successful results. By creating a more ergonomically favorable operating posture, a surgeon may be able to obtain greater precision and success in phonomicrosurgery. Phonomicrosurgery requires the precise manipulation of long-handled cantilevered instruments through the narrow bore of a laryngoscope. The head-mounted microscope shortens the working distance compared with a stand microscope, thereby increasing arm stability, which may improve surgical precision. Also, the head-mounted design permits flexibility in head position, enabling operator comfort, and delaying musculoskeletal fatigue. A head-mounted microscope decreases the working distance and provides better ergonomics in laryngoscopic microsurgery. These advances provide the potential to promote precision in phonomicrosurgery. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  18. Flatfielding Errors in Strömvil CCD Photometry

    Directory of Open Access Journals (Sweden)

    Boyle R. P.

    2003-12-01

    Full Text Available The importance of determining the error of the flat field in CCD photometry is detailed and our methods of doing this are described. We now have reached a precision of 1-1.5 % in our photometry. Color-magnitude diagrams of the open cluster M67 (ours and Laugalys et al. 2003 are compared.

  19. Channel uranium-graphite reactor mounting

    International Nuclear Information System (INIS)

    Polushkin, K.K.; Kuznetsov, A.G.; Zheleznyakov, B.N.

    1981-01-01

    According to theoretical principles of general engineering technology the engineering experience of construction-mounting works at the NPP with channel uranium-graphite reactors is systematized. Main parameters and structural features of the 1000 MW channel uranium-graphite reactors are considered. The succession of mounting operations, premounting equipment and pipelines preparation and mounting works technique are described. The most efficient methods of fitting, welding and machining of reactor elements are recommended. Main problems of technical control service are discussed. A typical netted diagram of main equipment of channel uranium-graphite reactors mounting is given

  20. A FORTRAN version implementation of block adjustment of CCD frames and its preliminary application

    Science.gov (United States)

    Yu, Y.; Tang, Z.-H.; Li, J.-L.; Zhao, M.

    2005-09-01

    A FORTRAN version implementation of the block adjustment (BA) of overlapping CCD frames is developed and its flowchart is shown. The program is preliminarily applied to obtain the optical positions of four extragalactic radio sources. The results show that because of the increase in the number and sky coverage of reference stars the precision of optical positions with BA is improved compared with the single CCD frame adjustment.

  1. Potassium secretion in mammalian distal colon

    DEFF Research Database (Denmark)

    Sørensen, Mads Vaarby

    2009-01-01

    Epithelial organs adjust the „inner milieu“ of the body and are crucial for all homeostatic processes. Epithelial transport of different solutes and water is regulated phenomena. The regulation processes include both long term hormonal regulation and short term local agonist mediated regulation....... This research project is the summary of 3 original papers addressing the functional role of different regulating factors on ion transport in mouse distal colon. The first paper addresses the effect of luminal nucleotides on electrogenic Na+ absorption. The distal colon, like the distal nephron is an aldosterone......-sensitive tissue and participates in the regulation of Na+ excretion. In the distal nephron it was found that luminal nucleotides inhibit ENaC-mediated Na+ absorption. Here it was addressed whether luminal nucleotides regulate Na+ absorption and if so, which of the known luminal P2 receptors are involved. Using...

  2. BVR Standardization of the CCD Photometric System of Chungbuk National University Observatory

    Directory of Open Access Journals (Sweden)

    Jang-Hae Jeong

    2009-06-01

    Full Text Available BVR observations for 52 standard stars were performed using the 1-m reflecter with 2K CCD System of Chungbuk National University Observatory(CBNUO in 2008. We obtained 1,322 CCD images to establish a correlation between our bvr system and the standard Johnson-Cousins BVR system. We derived the tentative equations of transformation between then as follows; V = v-0.0303(B-V+0.0466 B-V = 1.3475(b-v-0.0251 V-R = 1.0641(v-r-0.0125 Using these equations the magnitudes in V, B-V, and V-R for 197 stars were obtained.

  3. CCD Camera Lens Interface for Real-Time Theodolite Alignment

    Science.gov (United States)

    Wake, Shane; Scott, V. Stanley, III

    2012-01-01

    Theodolites are a common instrument in the testing, alignment, and building of various systems ranging from a single optical component to an entire instrument. They provide a precise way to measure horizontal and vertical angles. They can be used to align multiple objects in a desired way at specific angles. They can also be used to reference a specific location or orientation of an object that has moved. Some systems may require a small margin of error in position of components. A theodolite can assist with accurately measuring and/or minimizing that error. The technology is an adapter for a CCD camera with lens to attach to a Leica Wild T3000 Theodolite eyepiece that enables viewing on a connected monitor, and thus can be utilized with multiple theodolites simultaneously. This technology removes a substantial part of human error by relying on the CCD camera and monitors. It also allows image recording of the alignment, and therefore provides a quantitative means to measure such error.

  4. Detector Mount Design for IGRINS

    Directory of Open Access Journals (Sweden)

    Jae Sok Oh

    2014-06-01

    Full Text Available The Immersion Grating Infrared Spectrometer (IGRINS is a near-infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG Focal Plane Array (H2RG FPA detectors. We present the design and fabrication of the detector mount for the H2RG detector. The detector mount consists of a detector housing, an ASIC housing, a Field Flattener Lens (FFL mount, and a support base frame. The detector and the ASIC housing should be kept at 65 K and the support base frame at 130 K. Therefore they are thermally isolated by the support made of GFRP material. The detector mount is designed so that it has features of fine adjusting the position of the detector surface in the optical axis and of fine adjusting yaw and pitch angles in order to utilize as an optical system alignment compensator. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the structural and thermal analysis, the designed detector mount meets an optical stability tolerance and system thermal requirements. Actual detector mount fabricated based on the design has been installed into the IGRINS cryostat and successfully passed a vacuum test and a cold test.

  5. Mount Athos: Between autonomy and statehood

    Directory of Open Access Journals (Sweden)

    Avramović Dragutin

    2013-01-01

    Full Text Available Legal status of the Mount Athos is characterized by many special features that make it internationally unique legal regime. The author analyzes peculiarities of Mount Athos territorial status, legal position of residents and visitors, as well as organization of Mount Athos authorities. The author concludes that the Mount Athos is characterized by a kind of para-sovereignty. Its autonomy involves not only the internal organization, autonomous governance and religious autonomy, but it also includes many elements of secular life of their visitors. Mount Athos has its own, separate legislative, administrative and judicial powers, while the Statute of the Mount Athos has greater legal force than all the other laws of the Greek state, because the state can not unilaterally change its provisions. Having in mind that the wide self-government is vested in church authorities and that the monks have very specific way of living, the author takes a position that the Mount Athos represent 'monastic state', but without statehood. The author also states that the Mount Athos will be faced with many challenges in the context of spreading of an assimilating, universal conception of human rights.

  6. 77 FR 42713 - Notice of Proposed Information Collection RequestsNPEFS 2011-2014: Common Core of Data (CCD...

    Science.gov (United States)

    2012-07-20

    ... Core of Data (CCD) National Public Education Financial Survey AGENCY: Institute of Education Sciences, Department of Education. SUMMARY: The National Public Education Financial Survey (NPEFS) is an annual... of Data (CCD) National Public Education Financial Survey. OMB Control Number: 1850-0067. [[Page 42714...

  7. Noise in off-axis type holograms including reconstruction and CCD camera parameters

    Energy Technology Data Exchange (ETDEWEB)

    Voelkl, Edgar, E-mail: edgar.voelkl@fei.com [FEI Company, 5350 NE Dawson Creek Drive, Hillsboro, OR 97124-5793 (United States)

    2010-02-15

    Phase and amplitude images as contained in digital holograms are commonly extracted via a process called 'reconstruction'. Expressions for the expected noise in these images have been given in the past by several authors; however, the effect of the actual reconstruction process has not been fully appreciated. By starting with the Quantum Mechanical intensity distribution of the off-axis type interference pattern, then building the digital hologram on an electron-by-electron base while simultaneously reconstructing the phase/amplitude images and evaluating their noise levels, an expression is derived that consistently describes the noise in simulated and experimental phase/amplitude images and contains the reconstruction parameters. Because of the necessity to discretize the intensity distribution function, the digitization effects of an ideal CCD camera had to be included. Subsequently, this allowed a comparison between real and simulated holograms which then led to a comparison between the performance of an 'ideal' CCD camera versus a real device. It was concluded that significant improvement of the phase and amplitude noise may be obtained if CCD cameras were optimized for digitizing intensity distributions at low sampling rates.

  8. A New CCD Camera at the Molėtai Observatory

    Directory of Open Access Journals (Sweden)

    Zdanavičius J.

    2003-12-01

    Full Text Available The results of the first testing of a new CCD camera of the Molėtai Observatory are given. The linearity and the flat field corrections of good accuracy are determined by using shifted star field exposures.

  9. Combined open proximal and stent-graft distal repair for distal arch aneurysms: an alternative to total debranching.

    Science.gov (United States)

    Zierer, Andreas; Sanchez, Luis A; Moon, Marc R

    2009-07-01

    We present herein a novel, combined, simultaneous open proximal and stent-graft distal repair for complex distal aortic arch aneurysms involving the descending aorta. In the first surgical step, the transverse arch is opened during selective antegrade cerebral perfusion, and a Dacron graft (DuPont, Wilmington, DE) is positioned down the descending aorta in an elephant trunk-like fashion with its proximal free margin sutured circumferentially to the aorta just distal to the left subclavian or left common carotid artery. With the graft serving as the new proximal landing zone, subsequent endovascular repair is performed antegrade during rewarming through the ascending aorta.

  10. Development of network based control and data acquisition systems for diagnostics using CCD detectors. Application to LHD experiments

    International Nuclear Information System (INIS)

    Kado, Shinichiro; Nakanishi, Hideya; Ida, Katsumi; Kojima, Mamoru

    2000-01-01

    The needs of CCD detectors as a plasma diagnostic tool have recently been increased. However, many CCD providers have developed their own controlling systems, and it is difficult to customized the usages in order to make them applicable to the network-based data acquisition clusters which consist of various sorts of diagnostics. This paper presents the development of systems in which CCD detectors are controlled and the data are acquired through networks. By making use of the Client/Server (C/S) model in the Windows NT operating system and block transfer method via shared memory relevant to the model, the dependence on the hardware is hidden by the server service, CCD list sequencer. The client program is designed for the LHD (Large Helical Device) discharge operation sequences and the data acquisition system. (author)

  11. New Design Concept for Universal CCD Controller

    Directory of Open Access Journals (Sweden)

    Wonyong Han

    1994-06-01

    Full Text Available Currently, the CCDs are widely used in astronomical observations either in direct imaging use or spectroscopic mode. However according to the recent technical advances, new large format CCDs are rapidly developed which have better performances with higher quantum efficiency and sensitivity. In many cases, some microprocessors have been adopted to deal with necessary digital logic for a CCD imaging system. This could often lack the flexibility of a system for a user to upgrade with new devices, especially of it is a commercial product. A new design concept has been explored which could provide the opportunity to deal with any format of devices from ant manufactures effectively for astronomical purposes. Recently available PLD (Programmable Logic Devices technology makes it possible to develop such digital circuit design, which can be integrated into a single component, instead of using microprocessors. The design concept could dramatically increase the efficiency and flexibility of a CCD imaging system, particularly when new or large format devices are available and to upgrade the performance of a system. Some variable system control parameters can be selected by a user with a wider range of choice. The software can support such functional requirements very conveniently. This approach can be applied not only to astronomical purpose, but also to some related fields, such as remote sensing and industrial applications.

  12. Distal clavicular osteolysis: MR evidence for subchondral fracture

    Energy Technology Data Exchange (ETDEWEB)

    Kassarjian, Ara; Palmer, William E. [Massachusetts General Hospital, Department of Radiology, Division of Musculoskeletal Radiology, Yawkey Center, Boston, MA (United States); Llopis, Eva [Hospital de la Ribera, Department of Radiology, Valencia (Spain)

    2007-01-15

    To investigate the association between distal clavicular osteolysis and subchondral fractures of the distal clavicle at MRI. This study was approved by the hospital human research committee, which waived the need for informed consent. Three radiologists retrospectively analyzed 36 shoulder MR examinations in 36 patients with imaging findings of distal clavicular osteolysis. The presence of a subchondral fracture of the distal clavicle, abnormalities of the acromioclavicular joint, rotator cuff tears and labral tears were assessed by MRI. These cases were then compared with 36 age-matched controls. At MRI, 31 of 36 patients (86%) had a subchondral line within the distal clavicular edema, consistent with a subchondral fracture. Of the 36 patients, 32 (89%) had fluid in the acromioclavicular joint, while 27 of 36 patients (75%) had cysts or erosions in the distal clavicle. There were 13 patients (36%) with associated labral tears, while eight patients (22%) had partial-thickness rotator cuff tears. In the control group one of 36 (3%) had a subchondral line (P<0.05), while ten of 36 (28%) had rotator cuff tears and 13 of 36 (36%) had labral tears. These latter two were not statistically significant between the groups. A distal clavicular subchondral fracture is a common finding in patients with imaging evidence of distal clavicular osteolysis. These subchondral fractures may be responsible for the propensity of findings occurring on the clavicular side of the acromioclavicular joint. (orig.)

  13. Distal clavicular osteolysis: MR evidence for subchondral fracture

    International Nuclear Information System (INIS)

    Kassarjian, Ara; Palmer, William E.; Llopis, Eva

    2007-01-01

    To investigate the association between distal clavicular osteolysis and subchondral fractures of the distal clavicle at MRI. This study was approved by the hospital human research committee, which waived the need for informed consent. Three radiologists retrospectively analyzed 36 shoulder MR examinations in 36 patients with imaging findings of distal clavicular osteolysis. The presence of a subchondral fracture of the distal clavicle, abnormalities of the acromioclavicular joint, rotator cuff tears and labral tears were assessed by MRI. These cases were then compared with 36 age-matched controls. At MRI, 31 of 36 patients (86%) had a subchondral line within the distal clavicular edema, consistent with a subchondral fracture. Of the 36 patients, 32 (89%) had fluid in the acromioclavicular joint, while 27 of 36 patients (75%) had cysts or erosions in the distal clavicle. There were 13 patients (36%) with associated labral tears, while eight patients (22%) had partial-thickness rotator cuff tears. In the control group one of 36 (3%) had a subchondral line (P<0.05), while ten of 36 (28%) had rotator cuff tears and 13 of 36 (36%) had labral tears. These latter two were not statistically significant between the groups. A distal clavicular subchondral fracture is a common finding in patients with imaging evidence of distal clavicular osteolysis. These subchondral fractures may be responsible for the propensity of findings occurring on the clavicular side of the acromioclavicular joint. (orig.)

  14. Phase shifting white light interferometry using colour CCD for optical metrology and bio-imaging applications

    Science.gov (United States)

    Upputuri, Paul Kumar; Pramanik, Manojit

    2018-02-01

    Phase shifting white light interferometry (PSWLI) has been widely used for optical metrology applications because of their precision, reliability, and versatility. White light interferometry using monochrome CCD makes the measurement process slow for metrology applications. WLI integrated with Red-Green-Blue (RGB) CCD camera is finding imaging applications in the fields optical metrology and bio-imaging. Wavelength dependent refractive index profiles of biological samples were computed from colour white light interferograms. In recent years, whole-filed refractive index profiles of red blood cells (RBCs), onion skin, fish cornea, etc. were measured from RGB interferograms. In this paper, we discuss the bio-imaging applications of colour CCD based white light interferometry. The approach makes the measurement faster, easier, cost-effective, and even dynamic by using single fringe analysis methods, for industrial applications.

  15. Cooling System for a Frame-Store PN-CCD Detector for Low Background Application

    CERN Document Server

    Pereira, H; Santos Silva, P; Kuster, M; Lang, P

    2012-01-01

    The astroparticle physics experiment CERN Axion Solar Telescope (CAST) aims to detect hypothetical axions or axion-like particles produced in the Sun by the Primakoff process. A Large Hadron Collider (LHC) prototype superconducting dipole magnet provides a 9 T transverse magnetic field for the conversion of axions into detectable X-ray photons. These photons are detected with an X-ray telescope and a novel type of frame-store CCD detector built from radio-pure materials, installed in the optics focal plane. A novel type of cooling system has been designed and built based on krypton-filled cryogenic heat pipes, made out of oxygen-free radiopure copper, and a Stirling cryocooler as cold source. The heat pipes provide an efficient thermal coupling between the cryocooler and the CCD which is kept at stable temperatures between 150 and 230 K within an accuracy of 0.1 K. A graded-Z radiation shield, also serving as a gas cold-trap operated at 120 K, is implemented to reduce the surface contamination of the CCD wind...

  16. Development of X-ray CCD camera system with high readout rate using ASIC

    International Nuclear Information System (INIS)

    Nakajima, Hiroshi; Matsuura, Daisuke; Anabuki, Naohisa; Miyata, Emi; Tsunemi, Hiroshi; Doty, John P.; Ikeda, Hirokazu; Katayama, Haruyoshi

    2009-01-01

    We report on the development of an X-ray charge-coupled device (CCD) camera system with high readout rate using application-specific integrated circuit (ASIC) and Camera Link standard. The distinctive ΔΣ type analog-to-digital converter is introduced into the chip to achieve effective noise shaping and to obtain a high resolution with relatively simple circuits. The unit test proved moderately low equivalent input noise of 70μV with a high readout pixel rate of 625 kHz, while the entire chip consumes only 100 mW. The Camera Link standard was applied for the connectivity between the camera system and frame grabbers. In the initial test of the whole system, we adopted a P-channel CCD with a thick depletion layer developed for X-ray CCD camera onboard the next Japanese X-ray astronomical satellite. The characteristic X-rays from 109 Cd were successfully read out resulting in the energy resolution of 379(±7)eV (FWHM) at 22.1 keV, that is, ΔE/E=1.7% with a readout rate of 44 kHz.

  17. CCD characterization and measurements automation

    International Nuclear Information System (INIS)

    Kotov, I.V.; Frank, J.; Kotov, A.I.; Kubanek, P.; O'Connor, P.; Prouza, M.; Radeka, V.; Takacs, P.

    2012-01-01

    Modern mosaic cameras have grown both in size and in number of sensors. The required volume of sensor testing and characterization has grown accordingly. For camera projects as large as the LSST, test automation becomes a necessity. A CCD testing and characterization laboratory was built and is in operation for the LSST project. Characterization of LSST study contract sensors has been performed. The characterization process and its automation are discussed, and results are presented. Our system automatically acquires images, populates a database with metadata information, and runs express analysis. This approach is illustrated on 55 Fe data analysis. 55 Fe data are used to measure gain, charge transfer efficiency and charge diffusion. Examples of express analysis results are presented and discussed.

  18. Flush Mounting Of Thin-Film Sensors

    Science.gov (United States)

    Moore, Thomas C., Sr.

    1992-01-01

    Technique developed for mounting thin-film sensors flush with surfaces like aerodynamic surfaces of aircraft, which often have compound curvatures. Sensor mounted in recess by use of vacuum pad and materials selected for specific application. Technique involves use of materials tailored to thermal properties of substrate in which sensor mounted. Together with customized materials, enables flush mounting of thin-film sensors in most situations in which recesses for sensors provided. Useful in both aircraft and automotive industries.

  19. The Cross-Cultural Dementia Screening (CCD): A new neuropsychological screening instrument for dementia in elderly immigrants.

    Science.gov (United States)

    Goudsmit, Miriam; Uysal-Bozkir, Özgül; Parlevliet, Juliette L; van Campen, Jos P C M; de Rooij, Sophia E; Schmand, Ben

    2017-03-01

    Currently, approximately 3.9% of the European population are non-EU citizens, and a large part of these people are from "non-Western" societies, such as Turkey and Morocco. For various reasons, the incidence of dementia in this group is expected to increase. However, cognitive testing is challenging due to language barriers and low education and/or illiteracy. The newly developed Cross-Cultural Dementia Screening (CCD) can be administered without an interpreter. It contains three subtests that assess memory, mental speed, and executive function. We hypothesized the CCD to be a culture-fair test that could discriminate between demented patients and cognitively healthy controls. To test this hypothesis, 54 patients who had probable dementia were recruited via memory clinics. Controls (N = 1625) were recruited via their general practitioners. All patients and controls were aged 55 years and older and of six different self-defined ethnicities (Dutch, Turkish, Moroccan-Arabic, Moroccan-Berber, Surinamese-Creole, and Surinamese-Hindustani). Exclusion criteria included current or previous conditions that affect cognitive functioning. There were performance differences between the ethnic groups, but these disappeared after correcting for age and education differences between the groups, which supports our central hypothesis that the CCD is a culture-fair test. Receiver-operating characteristic (ROC) and logistic regression analyses showed that the CCD has high predictive validity for dementia (sensitivity: 85%; specificity: 89%). The CCD is a sensitive and culture-fair neuropsychological instrument for dementia screening in low-educated immigrant populations.

  20. New design for the UCO/Lick Observatory CCD guide camera

    Science.gov (United States)

    Wei, Mingzhi; Stover, Richard J.

    1996-03-01

    A new CCD based field acquisition and telescope guiding camera is being designed and built at UCO/Lick Observatory. Our goal is a camera which is fully computer controllable, compact in size, versatile enough to provide a wide variety of image acquisition modes, and able to operate with a wide variety of CCD detectors. The camera will improve our remote-observing capabilities since it will be easy to control the camera and obtain images over the Observatory computer network. To achieve the desired level of operating flexibility, the design incorporates state-of-the-art technologies such as high density, high speed programmable logic devices and non-volatile static memory. Various types of CCDs can be used in this system without major modification of the hardware or software. Though fully computer controllable, the camera can be operated as a stand-alone unit with most operating parameters set locally. A stand-alone display subsystem is also available. A thermoelectric device is used to cool the CCD to about -45c. Integration times can be varied over a range of 0.1 to 1000 seconds. High speed pixel skipping in both horizontal and vertical directions allows us to quickly access a selected subarea of the detector. Three different read out speeds allow the astronomer to select between high-speed/high-noise and low-speed/low-noise operation. On- chip pixel binning and MPP operation are also selectable options. This system can provide automatic sky level measurement and subtraction to accommodate dynamically changing background levels.

  1. Fast event recorder utilizing a CCD analog shift register

    International Nuclear Information System (INIS)

    Ducar, R.J.; McIntyre, P.M.

    1978-01-01

    A system of electronics has been developed to allow the capture and recording of relatively fast, low-amplitude analog events. The heart of the system is a dual 455-cell analog shift register charge-coupled device, Fairchild CCD321ADC-3. The CCD is operated in a dual clock mode. The input is sampled at a selectable clock rate of .25-20 MHz. The stored analog data is then clocked out at a slower rate, typically about .25 MHz. The time base expansion of the analog data allows for analog-to-digital conversion and memory storage using conventional medium-speed devices. The digital data is sequentially loaded into a static RAM and may then be block transferred to a computer. The analog electronics are housed in a single-width NIM module, and the RAM memory in a single-width CAMAC module. Each pair of modules provides six parallel channels. Cost is about $200.00 per channel. Applications are described for ionization imaging (TPC, IRC) and long-drift calorimetry in liquid argon

  2. The development of large-aperture test system of infrared camera and visible CCD camera

    Science.gov (United States)

    Li, Yingwen; Geng, Anbing; Wang, Bo; Wang, Haitao; Wu, Yanying

    2015-10-01

    Infrared camera and CCD camera dual-band imaging system is used in many equipment and application widely. If it is tested using the traditional infrared camera test system and visible CCD test system, 2 times of installation and alignment are needed in the test procedure. The large-aperture test system of infrared camera and visible CCD camera uses the common large-aperture reflection collimator, target wheel, frame-grabber, computer which reduces the cost and the time of installation and alignment. Multiple-frame averaging algorithm is used to reduce the influence of random noise. Athermal optical design is adopted to reduce the change of focal length location change of collimator when the environmental temperature is changing, and the image quality of the collimator of large field of view and test accuracy are also improved. Its performance is the same as that of the exotic congener and is much cheaper. It will have a good market.

  3. Comparison of a CCD and an APS for soft X-ray diffraction

    International Nuclear Information System (INIS)

    Stewart, Graeme; Bates, R; Blue, A; Maneuski, D; Clark, A; Turchetta, R; Dhesi, S S; Marchal, J; Steadman, P; Tartoni, N

    2011-01-01

    We compare a new CMOS Active Pixel Sensor (APS) to a Princeton Instruments PIXIS-XO: 2048B Charge Coupled Device (CCD) with soft X-rays tested in a synchrotron beam line at the Diamond Light Source (DLS). Despite CCDs being established in the field of scientific imaging, APS are an innovative technology that offers advantages over CCDs. These include faster readout, higher operational temperature, in-pixel electronics for advanced image processing and reduced manufacturing cost. The APS employed was the Vanilla sensor designed by the MI3 collaboration and funded by an RCUK Basic technology grant. This sensor has 520 x 520 square pixels, of size 25 μm on each side. The sensor can operate at a full frame readout of up to 20 Hz. The sensor had been back-thinned, to the epitaxial layer. This was the first time that a back-thinned APS had been demonstrated at a beam line at DLS. In the synchrotron experiment soft X-rays with an energy of approximately 708 eV were used to produce a diffraction pattern from a permalloy sample. The pattern was imaged at a range of integration times with both sensors. The CCD had to be operated at a temperature of -55°C whereas the Vanilla was operated over a temperature range from 20°C to -10°C. We show that the APS detector can operate with frame rates up to two hundred times faster than the CCD, without excessive degradation of image quality. The signal to noise of the APS is shown to be the same as that of the CCD at identical integration times and the response is shown to be linear, with no charge blooming effects. The experiment has allowed a direct comparison of back thinned APS and CCDs in a real soft x-ray synchrotron experiment.

  4. Comparison of a CCD and an APS for soft X-ray diffraction

    Science.gov (United States)

    Stewart, Graeme; Bates, R.; Blue, A.; Clark, A.; Dhesi, S. S.; Maneuski, D.; Marchal, J.; Steadman, P.; Tartoni, N.; Turchetta, R.

    2011-12-01

    We compare a new CMOS Active Pixel Sensor (APS) to a Princeton Instruments PIXIS-XO: 2048B Charge Coupled Device (CCD) with soft X-rays tested in a synchrotron beam line at the Diamond Light Source (DLS). Despite CCDs being established in the field of scientific imaging, APS are an innovative technology that offers advantages over CCDs. These include faster readout, higher operational temperature, in-pixel electronics for advanced image processing and reduced manufacturing cost. The APS employed was the Vanilla sensor designed by the MI3 collaboration and funded by an RCUK Basic technology grant. This sensor has 520 x 520 square pixels, of size 25 μm on each side. The sensor can operate at a full frame readout of up to 20 Hz. The sensor had been back-thinned, to the epitaxial layer. This was the first time that a back-thinned APS had been demonstrated at a beam line at DLS. In the synchrotron experiment soft X-rays with an energy of approximately 708 eV were used to produce a diffraction pattern from a permalloy sample. The pattern was imaged at a range of integration times with both sensors. The CCD had to be operated at a temperature of -55°C whereas the Vanilla was operated over a temperature range from 20°C to -10°C. We show that the APS detector can operate with frame rates up to two hundred times faster than the CCD, without excessive degradation of image quality. The signal to noise of the APS is shown to be the same as that of the CCD at identical integration times and the response is shown to be linear, with no charge blooming effects. The experiment has allowed a direct comparison of back thinned APS and CCDs in a real soft x-ray synchrotron experiment.

  5. Characterization of Engine Mount Elastomers

    National Research Council Canada - National Science Library

    Szabo, Jeffrey P

    2005-01-01

    As part of a project to develop methods for modelling the performance of engine mounts, several oil resistant alternative materials were prepared, and compared to conventional materials from mounts...

  6. The possibilities of CCD photometry of optical afterglows of GRBs

    Czech Academy of Sciences Publication Activity Database

    Šimon, Vojtěch; Polášek, Cyril; Jelínek, M.; Hudec, René; Štrobl, Jan

    -, č. 125 (2010), s. 24-28 ISSN 1801-5964. [Conference on Variable Stars Research /41./. Prague, 27.11.2009-29.11.2009] Institutional research plan: CEZ:AV0Z10030501 Keywords : gamma-ray bursts * optical afterglows * CCD photometry Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics

  7. Defect inspection in hot slab surface: multi-source CCD imaging based fuzzy-rough sets method

    Science.gov (United States)

    Zhao, Liming; Zhang, Yi; Xu, Xiaodong; Xiao, Hong; Huang, Chao

    2016-09-01

    To provide an accurate surface defects inspection method and make the automation of robust image region of interests(ROI) delineation strategy a reality in production line, a multi-source CCD imaging based fuzzy-rough sets method is proposed for hot slab surface quality assessment. The applicability of the presented method and the devised system are mainly tied to the surface quality inspection for strip, billet and slab surface etcetera. In this work we take into account the complementary advantages in two common machine vision (MV) systems(line array CCD traditional scanning imaging (LS-imaging) and area array CCD laser three-dimensional (3D) scanning imaging (AL-imaging)), and through establishing the model of fuzzy-rough sets in the detection system the seeds for relative fuzzy connectedness(RFC) delineation for ROI can placed adaptively, which introduces the upper and lower approximation sets for RIO definition, and by which the boundary region can be delineated by RFC region competitive classification mechanism. For the first time, a Multi-source CCD imaging based fuzzy-rough sets strategy is attempted for CC-slab surface defects inspection that allows an automatic way of AI algorithms and powerful ROI delineation strategies to be applied to the MV inspection field.

  8. Unilateral maxillary molar distalization with zygoma-gear appliance.

    Science.gov (United States)

    Kilkis, Dogan; Bayram, Mehmet; Celikoglu, Mevlut; Nur, Metin

    2012-08-01

    The aim of this study was to present the orthodontic treatment of a 15-year-old boy with a unilateral maxillary molar distalization system, called the zygoma-gear appliance. It consisted of a zygomatic anchorage miniplate, an inner bow, and a Sentalloy closed coil spring (GAC International, Bohemia, NY). A distalizing force of 350 g was used during the distalization period. The unilateral Class II malocclusion was corrected in 5 months with the zygoma-gear appliance. The maxillary left first molar showed distalization of 4 mm with an inclination of 3°. The maxillary premolars moved distally with the help of the transseptal fibers. In addition, there were slight decreases in overjet (-0.5 mm) and maxillary incisor inclination (-1°), indicating no anchorage loss from the zygoma-gear appliance. Preadjusted fixed appliances (0.022 × 0.028-in, MBT system; 3M Unitek, Monrovia, Calif) were placed in both arches to achieve leveling and alignment. After 14 months of unilateral distalization with the zygoma-gear appliance and fixed appliances, Class I molar and canine relationships were established with satisfactory interdigitation of the posterior teeth. Acceptable overjet and overbite were also achieved. This article shows that this new system, the zygoma-gear appliance, can be used for unilateral maxillary molar distalization without anchorage loss. Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  9. BVRI CCD photometry of the globular cluster NGC 2808

    International Nuclear Information System (INIS)

    Alcaino, G.; Liller, W.; Alvarado, F.; Wenderoth, E.

    1990-01-01

    As a part of a continuing program, CCD color-magnitude diagrams are presented for the bright globular cluster NGC 2808 in the four colors comprising BVRI. From a comparison of four different CMDs with theoretical isochrones, an age of 16 + or - 2 Gyr is obtained, assuming a value for Fe/H near -1.3. 28 refs

  10. Biomechanics of the Proximal Radius Following Drilling of the Bicipital Tuberosity to Mimic Cortical Button Distal Biceps Repair Technique.

    Science.gov (United States)

    Oak, Nikhil R; Lien, John R; Brunfeldt, Alexander; Lawton, Jeffrey N

    2018-05-01

    A fracture through the proximal radius is a theoretical concern after cortical button distal biceps fixation in an active patient. The permanent, nonossified cortical defect and medullary tunnel is at risk during a fall eliciting rotational and compressive forces. We hypothesized that during simulated torsion and compression, in comparison with unaltered specimens, the cortical button distal biceps repair model would have decreased torsional and compressive strength and would fracture in the vicinity of the bicipital tuberosity bone tunnel. Sixteen fourth-generation composite radius Sawbones models were used in this controlled laboratory study. A bone tunnel was created through the bicipital tuberosity to mimic the exact bone tunnel, 8 mm near cortex and 3.2 mm far cortex, made for the BicepsButton distal biceps tendon repair. The radius was then prepared and mounted on either a torsional or compression testing device and compared with undrilled control specimens. Compression tests resulted in average failure loads of 9015.2 N in controls versus 8253.25 N in drilled specimens ( P = .074). Torsional testing resulted in an average failure torque of 27.3 Nm in controls and 19.3 Nm in drilled specimens ( P = .024). Average fracture angle was 35.1° in controls versus 21.1° in drilled. Gross fracture patterns were similar in compression testing; however, in torsional testing all fractures occurred through the bone tunnel in the drilled group. There are weaknesses in the vicinity of the bone tunnel in the proximal radius during biomechanical stress testing which may not be clinically relevant in nature. In cortical button fixation, distal biceps repairs creates a permanent, nonossified cortical defect with tendon interposed in the bone tunnel, which can alter the biomechanical properties of the proximal radius during compressive and torsional loading.

  11. Intra-Articular Osteotomy for Distal Humerus Malunion

    Directory of Open Access Journals (Sweden)

    René K. Marti

    2009-01-01

    Full Text Available Intra-articular osteotomy is considered in the rare case of malunion after a fracture of the distal humerus to restore humeral alignment and gain a functional arc of elbow motion. Traumatic and iatrogenic disruption of the limited blood flow to the distal end of the humerus resulting in avascular necrosis of capitellum or trochlea is a major pitfall of the this technically challenging procedure. Two cases are presented which illustrate the potential problems of intra-articular osteotomy for malunion of the distal humerus.

  12. A comparison of film and 3 digital imaging systems for natural dental caries detection: CCD, CMOS, PSP and film

    Energy Technology Data Exchange (ETDEWEB)

    Han, Won Jeong [Dankook University College of Medicine, Seoul (Korea, Republic of)

    2004-03-15

    To evaluate the diagnostic accuracy of occlusal and proximal caries detection using CCD, CMOS, PSP and film system. 32 occlusal and 30 proximal tooth surfaces were radiographed under standardized conditions using 3 digital systems; CCD (CDX-2000HQ, Biomedysis Co., Seoul, Korea), CMOS (Schick, Schick Inc., Long Island, USA), PSP (Digora FMX, Orion Co./Soredex, Helsinki, Finland) and 1 film system (Kodak Insight, Eastman Kodak, Rochester, USA). 5 observers examined the radiographs for occlusal and proximal caries using a 5-point confidence scale. The presence of caries was validated histologically and radiographically. Diagnostic accuracy was evaluated using ROC curve areas (AZ). Analysis using ROC curves revealed the area under each curve which indicated a diagnostic accuracy. For occlusal caries, Kodak Insight film had an Az of 0.765, CCD one of 0.730, CMOS one of 0.742 and PSP one of 0.735. For proximal caries, Kodak Insight film had an Az of 0.833, CCD one of 0.832, CMOS one of 0.828 and PSP one of 0.868. No statistically significant difference was noted between any of the imaging modalities. CCD, CMOS, PSP and film performed equally well in the detection of occlusal and proximal dental caries. CCD, CMOS and PSP-based digital images provided a level of diagnostic performance comparable to Kodak Insight film.

  13. A comparison of film and 3 digital imaging systems for natural dental caries detection: CCD, CMOS, PSP and film

    International Nuclear Information System (INIS)

    Han, Won Jeong

    2004-01-01

    To evaluate the diagnostic accuracy of occlusal and proximal caries detection using CCD, CMOS, PSP and film system. 32 occlusal and 30 proximal tooth surfaces were radiographed under standardized conditions using 3 digital systems; CCD (CDX-2000HQ, Biomedysis Co., Seoul, Korea), CMOS (Schick, Schick Inc., Long Island, USA), PSP (Digora FMX, Orion Co./Soredex, Helsinki, Finland) and 1 film system (Kodak Insight, Eastman Kodak, Rochester, USA). 5 observers examined the radiographs for occlusal and proximal caries using a 5-point confidence scale. The presence of caries was validated histologically and radiographically. Diagnostic accuracy was evaluated using ROC curve areas (AZ). Analysis using ROC curves revealed the area under each curve which indicated a diagnostic accuracy. For occlusal caries, Kodak Insight film had an Az of 0.765, CCD one of 0.730, CMOS one of 0.742 and PSP one of 0.735. For proximal caries, Kodak Insight film had an Az of 0.833, CCD one of 0.832, CMOS one of 0.828 and PSP one of 0.868. No statistically significant difference was noted between any of the imaging modalities. CCD, CMOS, PSP and film performed equally well in the detection of occlusal and proximal dental caries. CCD, CMOS and PSP-based digital images provided a level of diagnostic performance comparable to Kodak Insight film.

  14. Measuring a narrow Bessel beam spot by scanning a charge-coupled device (CCD) pixel

    International Nuclear Information System (INIS)

    Tiwari, S K; Ram, S P; Jayabalan, J; Mishra, S R

    2010-01-01

    By scanning a charge-coupled device (CCD) camera transverse to the beam axis and observing the variation in counts on a marked pixel, we demonstrate that we can measure a laser beam spot size smaller than the size of the CCD-pixel. We find this method particularly attractive for measuring the size of central spot of a Bessel beam, for which the established scanning knife-edge method does not work appropriately because of the large contribution of the rings surrounding the central spot to the signal

  15. Volar plating for distal radius fractures--do not trust the image intensifier when judging distal subchondral screw length.

    Science.gov (United States)

    Park, Derek H; Goldie, Boyd S

    2012-09-01

    The use of the volar plate to treat distal radius fractures is increasing but despite the theoretical advantages of a volar approach there have been reports of extensor tendon ruptures due to prominent screw tips protruding past the dorsal cortex. The valley in the intermediate column between Lister tubercle and the sigmoid notch of the distal radius makes it difficult to rely on fluoroscopy to judge screw length. Our aim was to quantify the dimensions of this valley and to demonstrate the danger of relying on intraoperative image intensification fluoroscopy to determine lengths of distal screws. We measured the depth of this valley in the intermediate column of the distal radius in 33 patients with computed tomographic (9 patients) or magnetic resonance image (24 patients) scans of the wrist. There was a consistent valley in all images examined [average 1.8 mm (95% confidence interval, 1.6-2.0 mm)]. Thirty-nine percent of wrists had a valley depth of at least 2 mm. Standard lateral views or rotation of the forearm to obtain oblique views does not identify prominent screw tips; and whatever the rotation of the forearm, screw tips protruding beyond dorsal cortex may look as if it is within the bone when in fact it is out. When drilling we suggest noting the depth at which the drill bit just penetrates dorsal cortex and routinely downsize the distal screw length by 2 mm. We caution against relying on flourosocopy when judging the length of the distal subchondral screws.

  16. BECN2 interacts with ATG14 through a metastable coiled-coil to mediate autophagy: BECN2 CCD Structure and Interaction with ATG14

    Energy Technology Data Exchange (ETDEWEB)

    Su, Minfei; Li, Yue; Wyborny, Shane; Neau, David; Chakravarthy, Srinivas; Levine, Beth; Colbert, Christopher L.; Sinha, Sangita C. (NDSU); (IIT); (Cornell); (UTSMC)

    2017-03-12

    ATG14 binding to BECN/Beclin homologs is essential for autophagy, a critical catabolic homeostasis pathway. Here, we show that the α-helical, coiled-coil domain (CCD) of BECN2, a recently identified mammalian BECN1 paralog, forms an antiparallel, curved homodimer with seven pairs of nonideal packing interactions, while the BECN2 CCD and ATG14 CCD form a parallel, curved heterodimer stabilized by multiple, conserved polar interactions. Compared to BECN1, the BECN2 CCD forms a weaker homodimer, but binds more tightly to the ATG14 CCD. Mutation of nonideal BECN2 interface residues to more ideal pairs improves homodimer self-association and thermal stability. Unlike BECN1, all BECN2 CCD mutants bind ATG14, although more weakly than wild type. Thus, polar BECN2 CCD interface residues result in a metastable homodimer, facilitating dissociation, but enable better interactions with polar ATG14 residues stabilizing the BECN2:ATG14 heterodimer. These structure-based mechanistic differences in BECN1 and BECN2 homodimerization and heterodimerization likely dictate competitive ATG14 recruitment.

  17. CCD-based vertex detectors

    CERN Document Server

    Damerell, C J S

    2005-01-01

    Over the past 20 years, CCD-based vertex detectors have been used to construct some of the most precise 'tracking microscopes' in particle physics. They were initially used by the ACCMOR collaboration for fixed target experiments in CERN, where they enabled the lifetimes of some of the shortest-lived charm particles to be measured precisely. The migration to collider experiments was accomplished in the SLD experiment, where the original 120 Mpixel detector was later upgraded to one with 307 Mpixels. This detector was used in a range of physics studies which exceeded the capability of the LEP detectors, including the most precise limit to date on the Bs mixing parameter. This success, and the high background hit densities that will inevitably be encountered at the future TeV-scale linear collider, have established the need for a silicon pixel-based vertex detector at this machine. The technical options have now been broadened to include a wide range of possible silicon imaging technologies as well as CCDs (mon...

  18. CCD Photometry Using Multiple Comparison Stars

    Directory of Open Access Journals (Sweden)

    Yonggi Kim

    2004-09-01

    Full Text Available The accuracy of CCD observations obtained at the Korean 1.8 m telescope has been studied. Seventeen comparison stars in the vicinity of the cataclysmic variable BG CMi have been measured. The ``artificial" star has been used instead of the ``control" star, what made possible to increase accuracy estimates by a factor of 1.3-2.1 times for ``good" and ``cloudy" nights, respectively. The algorithm of iterative determination of accuracy and weights of few comparison stars contributing to the artificial star, has been presented. The accuracy estimates for 13-mag stars are around 0.002 m mag for exposure times of 30 sec.

  19. Measuring high-resolution sky luminance distributions with a CCD camera.

    Science.gov (United States)

    Tohsing, Korntip; Schrempf, Michael; Riechelmann, Stefan; Schilke, Holger; Seckmeyer, Gunther

    2013-03-10

    We describe how sky luminance can be derived from a newly developed hemispherical sky imager (HSI) system. The system contains a commercial compact charge coupled device (CCD) camera equipped with a fish-eye lens. The projection of the camera system has been found to be nearly equidistant. The luminance from the high dynamic range images has been calculated and then validated with luminance data measured by a CCD array spectroradiometer. The deviation between both datasets is less than 10% for cloudless and completely overcast skies, and differs by no more than 20% for all sky conditions. The global illuminance derived from the HSI pictures deviates by less than 5% and 20% under cloudless and cloudy skies for solar zenith angles less than 80°, respectively. This system is therefore capable of measuring sky luminance with the high spatial and temporal resolution of more than a million pixels and every 20 s respectively.

  20. Conceptualizing distal drivers in land use competition

    DEFF Research Database (Denmark)

    Niewhöner, Jörg; Nielsen, Jonas Ø; Gasparri, Gasparri

    2016-01-01

    This introductory chapter explores the notion of ‘distal drivers’ in land use competition. Research has moved beyond proximate causes of land cover and land use change to focus on the underlying drivers of these dynamics. We discuss the framework of telecoupling within human–environment systems...... as a first step to come to terms with the increasingly distal nature of driving forces behind land use practices. We then expand the notion of distal as mainly a measure of Euclidian space to include temporal, social, and institutional dimensions. This understanding of distal widens our analytical scope...... for the analysis of land use competition as a distributed process to consider the role of knowledge and power, technology, and different temporalities within a relational or systemic analysis of practices of land use competition. We conclude by pointing toward the historical and social contingency of land use...

  1. Recording of radiation-induced optical density changes in doped agarose gels with a CCD camera

    International Nuclear Information System (INIS)

    Tarte, B.J.; Jardine, P.A.; Van Doorn, T.

    1996-01-01

    Full text: Spatially resolved dose measurement with iron-doped agarose gels is continuing to be investigated for applications in radiotherapy dosimetry. It has previously been proposed to use optical methods, rather than MRI, for dose measurement with such gels and this has been investigated using a spectrophotometer (Appleby A and Leghrouz A, Med Phys, 18:309-312, 1991). We have previously studied the use of a pencil beam laser for such optical density measurement of gels and are currently investigating charge-coupled devices (CCD) camera imaging for the same purpose but with the advantages of higher data acquisition rates and potentially greater spatial resolution. The gels used in these studies were poured, irradiated and optically analysed in Perspex casts providing gel sections 1 cm thick and up to 20 cm x 30 cm in dimension. The gels were also infused with a metal indicator dye (xylenol orange) to render the radiation induced oxidation of the iron in the gel sensitive to optical radiation, specifically in the green spectral region. Data acquisition with the CCD camera involved illumination of the irradiated gel section with a diffuse white light source, with the light from the plane of the gel section focussed to the CCD array with a manual zoom lens. The light was also filtered with a green colour glass filter to maximise the contrast between unirradiated and irradiated gels. The CCD camera (EG and G Reticon MC4013) featured a 1024 x 1024 pixel array and was interfaced to a PC via a frame grabber acquisition board with 8 bit resolution. The performance of the gel dosimeter was appraised in mapping of physical and dynamic wedged 6 MV X-ray fields. The results from the CCD camera detection system were compared with both ionisation chamber data and laser based optical density measurements of the gels. Cross beam profiles were extracted from each measurement system at a particular depth (eg. 2.3 cm for the physical wedge field) for direct comparison. A

  2. Fractures of the distal phalanx in the horse

    International Nuclear Information System (INIS)

    Yovich, J.V.

    1989-01-01

    Fractures of the distal phalanx are an important cause of lameness referable to the foot. Depending on the fracture configuration and articular involvement, conservative or surgical treatment may be required. Fractures of the distal phalanx have been divided into six categories based on fracture configuration. Discussion of clinical features, management, and prognosis for horses with distal phalangeal fractures is presented for each fracture type

  3. Solar panel parallel mounting configuration

    Science.gov (United States)

    Mutschler, Jr., Edward Charles (Inventor)

    1998-01-01

    A spacecraft includes a plurality of solar panels interconnected with a power coupler and an electrically operated device to provide power to the device when the solar cells are insolated. The solar panels are subject to bending distortion when entering or leaving eclipse. Spacecraft attitude disturbances are reduced by mounting each of the solar panels to an elongated boom made from a material with a low coefficient of thermal expansion, so that the bending of one panel is not communicated to the next. The boom may be insulated to reduce its bending during changes in insolation. A particularly advantageous embodiment mounts each panel to the boom with a single mounting, which may be a hinge. The single mounting prevents transfer of bending moments from the panel to the boom.

  4. Stroboscope Based Synchronization of Full Frame CCD Sensors

    OpenAIRE

    Shen, Liang; Feng, Xiaobing; Zhang, Yuan; Shi, Min; Zhu, Dengming; Wang, Zhaoqi

    2017-01-01

    The key obstacle to the use of consumer cameras in computer vision and computer graphics applications is the lack of synchronization hardware. We present a stroboscope based synchronization approach for the charge-coupled device (CCD) consumer cameras. The synchronization is realized by first aligning the frames from different video sequences based on the smear dots of the stroboscope, and then matching the sequences using a hidden Markov model. Compared with current synchronized capture equi...

  5. STARL -- a Program to Correct CCD Image Defects

    Science.gov (United States)

    Narbutis, D.; Vanagas, R.; Vansevičius, V.

    We present a program tool, STARL, designed for automatic detection and correction of various defects in CCD images. It uses genetic algorithm for deblending and restoring of overlapping saturated stars in crowded stellar fields. Using Subaru Telescope Suprime-Cam images we demonstrate that the program can be implemented in the wide-field survey data processing pipelines for production of high quality color mosaics. The source code and examples are available at the STARL website.

  6. A multiple CCD X-ray detector and its first operation with synchrotron radiation X-ray beam

    CERN Document Server

    Suzuki, M; Kumasaka, T; Sato, K; Toyokawa, H; Aries, I F; Jerram, P A; Ueki, T

    1999-01-01

    A 4x4 array structure of 16 identical CCD X-ray detector modules, called the multiple CCD X-ray detector system (MCCDX), was submitted to its first synchrotron radiation experiment at the protein crystallography station of the RIKEN beamline (BL45XU) at the SPring-8 facility. An X-ray diffraction pattern of cholesterol powder was specifically taken in order to investigate the overall system performance.

  7. Construction of a photochemical reactor combining a CCD spectrophotometer and a LED radiation source.

    Science.gov (United States)

    Gombár, Melinda; Józsa, Éva; Braun, Mihály; Ősz, Katalin

    2012-10-01

    An inexpensive photoreactor using LED light sources and a fibre-optic CCD spectrophotometer as a detector was built by designing a special cell holder for standard 1.000 cm cuvettes. The use of this device was demonstrated by studying the aqueous photochemical reaction of 2,5-dichloro-1,4-benzoquinone. The developed method combines the highly quantitative data collection of CCD spectrophotometers with the possibility of illuminating the sample independently of the detecting light beam, which is a substantial improvement of the method using diode array spectrophotometers as photoreactors.

  8. Flat Field Anomalies in an X-Ray CCD Camera Measured Using a Manson X-Ray Source

    International Nuclear Information System (INIS)

    Michael Haugh

    2008-01-01

    The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. It determines how accurately NIF can point the laser beams and is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 (micro)m square pixels, and 15 (micro)m thick. A multi-anode Manson X-ray source, operating up to 10kV and 2mA, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/ΔE ∼ 12. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within ±1.5% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. The efficiency pattern follows the properties of Si. The maximum quantum efficiency is 0.71. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation was >8% at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was less than the measurement uncertainty below 4 keV. We were also able to observe debris on the CCD chip. The debris showed maximum contrast at the lowest energy used, 930 eV, and disappeared by 4 keV. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager

  9. An X-ray CCD signal generator with true random arrival time

    International Nuclear Information System (INIS)

    Huo Jia; Xu Yuming; Chen Yong; Cui Weiwei; Li Wei; Zhang Ziliang; Han Dawei; Wang Yusan; Wang Juan

    2011-01-01

    An FPGA-based true random signal generator with adjustable amplitude and exponential distribution of time interval is presented. Since traditional true random number generators (TRNG) are resource costly and difficult to transplant, we employed a method of random number generation based on jitter and phase noise in ring oscillators formed by gates in an FPGA. In order to improve the random characteristics, a combination of two different pseudo-random processing circuits is used for post processing. The effects of the design parameters, such as sample frequency are discussed. Statistical tests indicate that the generator can well simulate the timing behavior of random signals with Poisson distribution. The X-ray CCD signal generator will be used in debugging the CCD readout system of the Low Energy X-ray Instrument onboard the Hard X-ray Modulation Telescope (HXMT). (authors)

  10. Dynamic Mapping of Rice Growth Parameters Using HJ-1 CCD Time Series Data

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2016-11-01

    Full Text Available The high temporal resolution (4-day charge-coupled device (CCD cameras onboard small environment and disaster monitoring and forecasting satellites (HJ-1A/B with 30 m spatial resolution and large swath (700 km have substantially increased the availability of regional clear sky optical remote sensing data. For the application of dynamic mapping of rice growth parameters, leaf area index (LAI and aboveground biomass (AGB were considered as plant growth indicators. The HJ-1 CCD-derived vegetation indices (VIs showed robust relationships with rice growth parameters. Cumulative VIs showed strong performance for the estimation of total dry AGB. The cross-validation coefficient of determination ( R C V 2 was increased by using two machine learning methods, i.e., a back propagation neural network (BPNN and a support vector machine (SVM compared with traditional regression equations of LAI retrieval. The LAI inversion accuracy was further improved by dividing the rice growth period into before and after heading stages. This study demonstrated that continuous rice growth monitoring over time and space at field level can be implemented effectively with HJ-1 CCD 10-day composite data using a combination of proper VIs and regression models.

  11. Developing a CCD camera with high spatial resolution for RIXS in the soft X-ray range

    Science.gov (United States)

    Soman, M. R.; Hall, D. J.; Tutt, J. H.; Murray, N. J.; Holland, A. D.; Schmitt, T.; Raabe, J.; Schmitt, B.

    2013-12-01

    The Super Advanced X-ray Emission Spectrometer (SAXES) at the Swiss Light Source contains a high resolution Charge-Coupled Device (CCD) camera used for Resonant Inelastic X-ray Scattering (RIXS). Using the current CCD-based camera system, the energy-dispersive spectrometer has an energy resolution (E/ΔE) of approximately 12,000 at 930 eV. A recent study predicted that through an upgrade to the grating and camera system, the energy resolution could be improved by a factor of 2. In order to achieve this goal in the spectral domain, the spatial resolution of the CCD must be improved to better than 5 μm from the current 24 μm spatial resolution (FWHM). The 400 eV-1600 eV energy X-rays detected by this spectrometer primarily interact within the field free region of the CCD, producing electron clouds which will diffuse isotropically until they reach the depleted region and buried channel. This diffusion of the charge leads to events which are split across several pixels. Through the analysis of the charge distribution across the pixels, various centroiding techniques can be used to pinpoint the spatial location of the X-ray interaction to the sub-pixel level, greatly improving the spatial resolution achieved. Using the PolLux soft X-ray microspectroscopy endstation at the Swiss Light Source, a beam of X-rays of energies from 200 eV to 1400 eV can be focused down to a spot size of approximately 20 nm. Scanning this spot across the 16 μm square pixels allows the sub-pixel response to be investigated. Previous work has demonstrated the potential improvement in spatial resolution achievable by centroiding events in a standard CCD. An Electron-Multiplying CCD (EM-CCD) has been used to improve the signal to effective readout noise ratio achieved resulting in a worst-case spatial resolution measurement of 4.5±0.2 μm and 3.9±0.1 μm at 530 eV and 680 eV respectively. A method is described that allows the contribution of the X-ray spot size to be deconvolved from these

  12. A data-acquisition system for high speed linear CCD

    International Nuclear Information System (INIS)

    Liu Zhiyan; Chen Xiangcai; Jiang Xiaoshan; Zhang Hongyu; Liang Zhongwang; Xiang Haisheng; Hu Jun

    2010-01-01

    A data-acquisition system for high speed linear CCD (Charge Coupled device) is mainly introduced. The optical fiber transmission technology is used. The data is sent to PC through USB or PCI interface. The construction of the system, the design of the PCI interface hardware, software design and the design of the control program running on host computer are also introduced. (authors)

  13. Measurements of 42 Wide CPM Pairs with a CCD

    Science.gov (United States)

    Harshaw, Richard

    2015-11-01

    This paper addresses the use of a Skyris 618C color CCD camera as a means of obtaining data for analysis in the measurement of wide common proper motion stars. The equipment setup is described and data collection procedure outlined. Results of the measures of 42 CPM stars are presented, showing the Skyris is a reliable device for the measurement of double stars.

  14. Posttraumatic osteolysis of the distal clavicula end

    International Nuclear Information System (INIS)

    Hermanns, P.H.; Beeger, R.; Koetter, D.; Hamburg Univ.

    1981-01-01

    Posttraumatic osteolysis of bone is rare. Its etiology is unknown. A case of posttraumatic osteolysis of the distal clavicle end is reported. Differentialdiagnostical and ethiological relations are discussed. The literature of posttraumatic osteolysis especially of distal clavicle osteolysis is reported. (orig.) [de

  15. Focal plane scanner with reciprocating spatial window

    Science.gov (United States)

    Mao, Chengye (Inventor)

    2000-01-01

    A focal plane scanner having a front objective lens, a spatial window for selectively passing a portion of the image therethrough, and a CCD array for receiving the passed portion of the image. All embodiments have a common feature whereby the spatial window and CCD array are mounted for simultaneous relative reciprocating movement with respect to the front objective lens, and the spatial window is mounted within the focal plane of the front objective. In a first embodiment, the spatial window is a slit and the CCD array is one-dimensional, and successive rows of the image in the focal plane of the front objective lens are passed to the CCD array by an image relay lens interposed between the slit and the CCD array. In a second embodiment, the spatial window is a slit, the CCD array is two-dimensional, and a prism-grating-prism optical spectrometer is interposed between the slit and the CCD array so as to cause the scanned row to be split into a plurality of spectral separations onto the CCD array. In a third embodiment, the CCD array is two-dimensional and the spatial window is a rectangular linear variable filter (LVF) window, so as to cause the scanned rows impinging on the LVF to be bandpass filtered into spectral components onto the CCD array through an image relay lens interposed between the LVF and the CCD array.

  16. Mounting Thin Samples For Electrical Measurements

    Science.gov (United States)

    Matus, L. G.; Summers, R. L.

    1988-01-01

    New method for mounting thin sample for electrical measurements involves use of vacuum chuck to hold a ceramic mounting plate, which holds sample. Contacts on mounting plate establish electrical connection to sample. Used to make electrical measurements over temperature range from 77 to 1,000 K and does not introduce distortions into magnetic field during Hall measurements.

  17. Design method of general-purpose driving circuit for CCD based on CPLD

    International Nuclear Information System (INIS)

    Zhang Yong; Tang Benqi; Xiao Zhigang; Wang Zujun; Huang Shaoyan

    2005-01-01

    It is very important for studying the radiation damage effects and mechanism systematically about CCD to develop a general-purpose test platform. The paper discusses the design method of general-purpose driving circuit for CCD based on CPLD and the realization approach. A main controller has being designed to read the data file from the outer memory, setup the correlative parameter registers and produce the driving pulses according with parameter request strictly, which is based on MAX7000S by using MAX-PLUS II software. The basic driving circuit module has being finished based on this method. The output waveform of the module is the same figure as the simulation waveform. The result indicates that the design method is feasible. (authors)

  18. A STUDY OF SURGICAL MANAGEMENT OF DISTAL FEMORAL FRACTURES BY DISTAL FEMORAL LOCKING COMPRESSION PLATE OSTEOSYNTHESIS

    Directory of Open Access Journals (Sweden)

    Dema Rajaiah

    2016-08-01

    Full Text Available AIMS AND OBJECTIVES To study the fractures of distal end of femur and the mechanism of injury in distal end femur fractures, the advantages and disadvantages of open reduction and internal fixation of distal end femur fractures by distal femoral locking compression plate osteosynthesis and to analyse the outcome in terms of range of Knee motion, time to union, and limb shortening. RESULTS The mean age of patient is 44 years, 85% are males, road traffic accidents account for majority (80%, right side involved in 70%, Muller’s type C fracture is common, good range of movements is seen 90% of cases and union occurred in 95% in 5 months. The results were assessed using Neer’s score, seven (35% patients had excellent results, eight (40% patients had good results, four (20% patients had fair results and one (5% patient had poor result. CONCLUSION From our study, we conclude that DF-LCP is a safe and reliable implant and has shown excellent to satisfactory results in majority of intra-articular fractures (AO type C. Fixation with locking compression plate showed more effectiveness in severely osteoporotic bones, shorter operative stay, faster recovery, faster union rates and excellent functional outcome.

  19. Development of Multiple-Element Flame Emission Spectrometer Using CCD Detection

    Science.gov (United States)

    Seney, Caryn S.; Sinclair, Karen V.; Bright, Robin M.; Momoh, Paul O.; Bozeman, Amelia D.

    2005-01-01

    The full wavelength coverage of charge coupled device (CCD) detector when coupled with an echelle spectrography, the system allows for simultaneously multiple element spectroscopy to be performed. The multiple-element flame spectrometer was built and characterized through the analysis of environmentally significant elements such as Ca, K, Na, Cu,…

  20. Distal radioulnar joint injuries

    Directory of Open Access Journals (Sweden)

    Binu P Thomas

    2012-01-01

    Full Text Available Distal radioulnar joint is a trochoid joint relatively new in evolution. Along with proximal radioulnar joint , forearm bones and interosseous membrane, it allows pronosupination and load transmission across the wrist. Injuries around distal radioulnar joint are not uncommon, and are usually associated with distal radius fractures,fractures of the ulnar styloid and with the eponymous Galeazzi or Essex_Lopresti fractures. The injury can be purely involving the soft tissue especially the triangular fibrocartilage or the radioulnar ligaments.The patients usually present with ulnar sided wrist pain, features of instability, or restriction of rotation. Difficulty in carrying loads in the hand is a major constraint for these patients. Thorough clinical examination to localize point of tenderness and appropriate provocative tests help in diagnosis. Radiology and MRI are extremely useful, while arthroscopy is the gold standard for evaluation. The treatment protocols are continuously evolving and range from conservative, arthroscopic to open surgical methods. Isolated dislocation are uncommon. Basal fractures of the ulnar styloid tend to make the joint unstable and may require operative intervention. Chronic instability requires reconstruction of the stabilizing ligaments to avoid onset of arthritis. Prosthetic replacement in arthritis is gaining acceptance in the management of arthritis.

  1. Resilient mounting systems in buildings

    NARCIS (Netherlands)

    Breeuwer, R.; Tukker, J.C.

    1976-01-01

    The basic elements of resilient mounting systems are described and various measures for quantifying the effect of such systems defined. Using electrical analogue circuits, the calculation of these measures is illustrated. With special reference to resilient mounting systems in buildings, under

  2. Performance of an area variable MOS varicap weighted programmable CCD transversal filter

    OpenAIRE

    Bhattacharyya, A.B.; Shankarnarayan, L.; Kapur, N.; Wallinga, Hans

    1981-01-01

    The performance of an electrically programmable CCD transversal filter (PTF) is presented in which tap-weight multiplication is performed by a novel and compact on chip voltage controlled area variable MOS varicap.

  3. Contemporary Management of Primary Distal Urethral Cancer

    NARCIS (Netherlands)

    Traboulsi, S.L.; Witjes, J.A.; Kassouf, W.

    2016-01-01

    Primary urethral cancer is one of the rare urologic tumors. Distal urethral tumors are usually less advanced at diagnosis compared with proximal tumors and have a good prognosis if treated appropriately. Low-stage distal tumors can be managed successfully with a surgical approach in men or radiation

  4. Distal technologies and type 1 diabetes management.

    Science.gov (United States)

    Duke, Danny C; Barry, Samantha; Wagner, David V; Speight, Jane; Choudhary, Pratik; Harris, Michael A

    2018-02-01

    Type 1 diabetes requires intensive self-management to avoid acute and long-term health complications. In the past two decades, substantial advances in technology have enabled more effective and convenient self-management of type 1 diabetes. Although proximal technologies (eg, insulin pumps, continuous glucose monitors, closed-loop and artificial pancreas systems) have been the subject of frequent systematic and narrative reviews, distal technologies have received scant attention. Distal technologies refer to electronic systems designed to provide a service remotely and include heterogeneous systems such as telehealth, mobile health applications, game-based support, social platforms, and patient portals. In this Review, we summarise the empirical literature to provide current information about the effectiveness of available distal technologies to improve type 1 diabetes management. We also discuss privacy, ethics, and regulatory considerations, issues of global adoption, knowledge gaps in distal technology, and recommendations for future directions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Low-Thermal-Resistance Baseplate Mounting

    Science.gov (United States)

    Perreault, W. T.

    1984-01-01

    Low-thermal-resistance mounting achieved by preloading baseplate to slight convexity with screws threaded through beam. As mounting bolts around edge of base-place tightened, baseplate and cold plate contact first in center, with region of intimate contact spreading outward as bolts tightened.

  6. Two Herbig-Haro objects discovered by narrow-band CCD imagery

    International Nuclear Information System (INIS)

    Ogura, Katsuo

    1990-01-01

    Two new Herbig-Haro objects, HH 132 and HH 133, have been discovered by CCD imagery behind interference filters on and just off the forbidden S II lines in the red. They are located in Puppis R2 and in Vela R2. Possible locations of their exciting sources are discussed. 12 refs

  7. An improved loopless mounting method for cryocrystallography

    International Nuclear Information System (INIS)

    Jian-Xun, Qi; Fan, Jiang

    2010-01-01

    Based on a recent loopless mounting method, a simplified loopless and bufferless crystal mounting method is developed for macromolecular crystallography. This simplified crystal mounting system is composed of the following components: a home-made glass capillary, a brass seat for holding the glass capillary, a flow regulator, and a vacuum pump for evacuation. Compared with the currently prevalent loop mounting method, this simplified method has almost the same mounting procedure and thus is compatible with the current automated crystal mounting system. The advantages of this method include higher signal-to-noise ratio, more accurate measurement, more rapid flash cooling, less x-ray absorption and thus less radiation damage to the crystal. This method can be extended to the flash-freeing of a crystal without or with soaking it in a lower concentration of cryoprotectant, thus it may be the best option for data collection in the absence of suitable cryoprotectant. Therefore, it is suggested that this mounting method should be further improved and extensively applied to cryocrystallographic experiments. (general)

  8. An improved loopless mounting method for cryocrystallography

    Science.gov (United States)

    Qi, Jian-Xun; Jiang, Fan

    2010-01-01

    Based on a recent loopless mounting method, a simplified loopless and bufferless crystal mounting method is developed for macromolecular crystallography. This simplified crystal mounting system is composed of the following components: a home-made glass capillary, a brass seat for holding the glass capillary, a flow regulator, and a vacuum pump for evacuation. Compared with the currently prevalent loop mounting method, this simplified method has almost the same mounting procedure and thus is compatible with the current automated crystal mounting system. The advantages of this method include higher signal-to-noise ratio, more accurate measurement, more rapid flash cooling, less x-ray absorption and thus less radiation damage to the crystal. This method can be extended to the flash-freeing of a crystal without or with soaking it in a lower concentration of cryoprotectant, thus it may be the best option for data collection in the absence of suitable cryoprotectant. Therefore, it is suggested that this mounting method should be further improved and extensively applied to cryocrystallographic experiments.

  9. Intra-articular osteotomy for distal humerus malunion

    NARCIS (Netherlands)

    Marti, René K.; Doornberg, Job

    2009-01-01

    Intra-articular osteotomy is considered in the rare case of malunion after a fracture of the distal humerus to restore humeral alignment and gain a functional arc of elbow motion. Traumatic and iatrogenic disruption of the limited blood flow to the distal end of the humerus resulting in avascular

  10. Distal Communication by Chimpanzees (Pan troglodytes): Evidence for Common Ground?

    Science.gov (United States)

    Leavens, David A; Reamer, Lisa A; Mareno, Mary Catherine; Russell, Jamie L; Wilson, Daniel; Schapiro, Steven J; Hopkins, William D

    2015-01-01

    van der Goot et al. (2014) proposed that distal, deictic communication indexed the appreciation of the psychological state of a common ground between a signaler and a receiver. In their study, great apes did not signal distally, which they construed as evidence for the human uniqueness of a sense of common ground. This study exposed 166 chimpanzees to food and an experimenter, at an angular displacement, to ask, "Do chimpanzees display distal communication?" Apes were categorized as (a) proximal or (b) distal signalers on each of four trials. The number of chimpanzees who communicated proximally did not statistically differ from the number who signaled distally. Therefore, contrary to the claim by van der Goot et al., apes do communicate distally. © 2015 The Authors. Child Development © 2015 Society for Research in Child Development, Inc.

  11. CCD polarimetry as a probe of regions of recent-star formation

    Energy Technology Data Exchange (ETDEWEB)

    Draper, P W

    1988-01-01

    Chapter 1 of this thesis details the incorporation of a Charged-Coupled Device (CCD) detector system with the Durham Imaging Polarimeter. The details include the physical characteristics of the device and the electronics and software associated with the device control and data storage. Chapter 2 of this work describes fully how suitable corrections for this effect can be made, and derives first-order results. The CCD performance is examined in comparison with the detector used previously and hence the veracity of the new results is established. Chapter 3 is a relevant summary of the status of the astronomy of the immediate regions of recent-star formation. Chapter 4 describes multicolor polarimetry of NGC2261/R Mon covering the period 1979 to 1986. The data conclusively prove that the polarization of R Mon must be due to effects close to R Mon (approx.14 astronomical units).

  12. A simple and accurate method for the quality control of the I.I.-DR apparatus using the CCD camera

    International Nuclear Information System (INIS)

    Igarashi, Hitoshi; Shiraishi, Akihisa; Kuraishi, Masahiko

    2000-01-01

    With the advancing development of CCD cameras, the I.I.-DR apparatus has been introduced into the x-ray fluoroscopy television system. Consequently, quality control of the system has become a complicated task. We developed a simple, accurate method for quality control of the I.I.-DR apparatus using the CCD camera. Experiments were separately performed for the imager system [laser imager, DDX (dynamic digital x-ray system)] and the imaging system (I.I., ND-filter, IRIS, CCD camera). Quality control of the imager system was done by simply examining both input and output characteristics with a sliding pattern. Quality control of the imaging system was also conducted by estimating AVE (the average volume element), which was obtained using a phantom under the constant conditions. The results indicated that this simplified method is useful as a weekly quality control check of the I.I.-DR apparatus using the CCD camera. (author)

  13. A CCD-based area detector for X-ray crystallography using synchrotron and laboratory sources

    International Nuclear Information System (INIS)

    Phillips, W.C.; Li Youli; Stanton, M.; Xie Yuanhui; O'Mara, D.; Kalata, K.

    1993-01-01

    The design and characteristics of a CCD-based area detector suitable for X-ray crystallographic studies using both synchrotron and laboratory sources are described. The active area is 75 mm in diameter, the FWHM of the point response function is 0.20 mm, and for Bragg peaks the dynamic range is 900 and the DQE ∼0.3. The 1320x1035-pixel Kodak CCD is read out into an 8 Mbyte memory system in 0.14 s and digitized to 12 bits. X-ray crystallographic data collected at the NSLS synchrotron from cubic insulin crystals are presented. (orig.)

  14. Distal displacement of the maxilla and the upper first molar.

    Science.gov (United States)

    Baumrind, S; Molthen, R; West, E E; Miller, D M

    1979-06-01

    Data from a sample of 198 Class II cases treated with various appliances which deliver distally directed forces to the maxilla were examined to determine the frequency of absolute distal displacement of the upper first molar and of the maxilla. Analysis revealed that such distal displacement is possible and that it is, in fact, a frequent finding following treatment. Long-range stability of distal displacement was not assessed.

  15. Distal splenorenal shunt with partial spleen resection

    Directory of Open Access Journals (Sweden)

    Gajin Predrag

    2007-01-01

    Full Text Available Introduction: Hypersplenism is a common complication of portal hypertension. Cytopenia in hypersplenism is predominantly caused by splenomegaly. Distal splenorenal shunt (Warren with partial spleen resection is an original surgical technique that regulates cytopenia by reduction of the enlarged spleen. Objective. The aim of our study was to present the advantages of distal splenorenal shunt (Warren with partial spleen resection comparing morbidity and mortality in a group of patients treated by distal splenorenal shunt with partial spleen resection with a group of patients treated only by a distal splenorenal shunt. Method. From 1995 to 2003, 41 patients with portal hypertension were surgically treated due to hypersplenism and oesophageal varices. The first group consisted of 20 patients (11 male, mean age 42.3 years who were treated by distal splenorenal shunt with partial spleen resection. The second group consisted of 21 patients (13 male, mean age 49.4 years that were treated by distal splenorenal shunt only. All patients underwent endoscopy and assessment of oesophageal varices. The size of the spleen was evaluated by ultrasound, CT or by scintigraphy. Angiography was performed in all patients. The platelet and white blood cell count and haemoglobin level were registered. Postoperatively, we noted blood transfusion, complications and total hospital stay. Follow-up period was 12 months, with first checkup after one month. Results In the first group, only one patient had splenomegaly postoperatively (5%, while in the second group there were 13 patients with splenomegaly (68%. Before surgery, the mean platelet count in the first group was 51.6±18.3x109/l, to 118.6±25.4x109/l postoperatively. The mean platelet count in the second group was 67.6±22.8x109/l, to 87.8±32.1x109/l postoperatively. Concerning postoperative splenomegaly, statistically significant difference was noted between the first and the second group (p<0.05. Comparing the

  16. Fiber-MZI-based FBG sensor interrogation: comparative study with a CCD spectrometer.

    Science.gov (United States)

    Das, Bhargab; Chandra, Vikash

    2016-10-10

    We present an experimental comparative study of the two most commonly used fiber Bragg grating (FBG) sensor interrogation techniques: a charge-coupled device (CCD) spectrometer and a fiber Mach-Zehnder interferometer (F-MZI). Although the interferometric interrogation technique is historically known to offer the highest sensitivity measurements, very little information exists regarding how it compares with the current commercially available spectral-characteristics-based interrogation systems. It is experimentally established here that the performance of a modern-day CCD spectrometer interrogator is very close to a F-MZI interrogator with the capability of measuring Bragg wavelength shifts with sub-picometer-level accuracy. The results presented in this research study can further be used as a guideline for choosing between the two FBG sensor interrogator types for small-amplitude dynamic perturbation measurements down to nano-level strain.

  17. Use of a CCD-based area detection system of a fibre diffractometer

    International Nuclear Information System (INIS)

    Hanna, S.; Windle, A.H.

    1995-01-01

    We describe a new X-ray fibre diffractometer, consisting of a commercial X-ray sensitive video camera coupled to a conventional 3 goniometer in place of a more traditional single-point detector. The active element of the video camera is a charge-coupled device (CCD). Diffraction images, obtained at various goniometer settings, are transformed into reciprocal space, and combined to give a complete section through the origin and parallel to the symmetry axis of cylindrically averaged reciprocal space. A greater density of measurements is needed in the vicinity of the reciprocal fibre axis in order to avoid information loss due to the curvature of the Ewald sphere. The pros and cons of using CCD's as X-ray detectors are discussed and sample results from polymer fibers are shown. 17 refs., 5 figs

  18. Multi-Mounted X-Ray Computed Tomography.

    Science.gov (United States)

    Fu, Jian; Liu, Zhenzhong; Wang, Jingzheng

    2016-01-01

    Most existing X-ray computed tomography (CT) techniques work in single-mounted mode and need to scan the inspected objects one by one. It is time-consuming and not acceptable for the inspection in a large scale. In this paper, we report a multi-mounted CT method and its first engineering implementation. It consists of a multi-mounted scanning geometry and the corresponding algebraic iterative reconstruction algorithm. This approach permits the CT rotation scanning of multiple objects simultaneously without the increase of penetration thickness and the signal crosstalk. Compared with the conventional single-mounted methods, it has the potential to improve the imaging efficiency and suppress the artifacts from the beam hardening and the scatter. This work comprises a numerical study of the method and its experimental verification using a dataset measured with a developed multi-mounted X-ray CT prototype system. We believe that this technique is of particular interest for pushing the engineering applications of X-ray CT.

  19. CCD Development Progress at Lawrence Berkeley National Laboratory

    OpenAIRE

    Kolbe, W.F.; Holland, S.E.; Bebek, C.J.

    2006-01-01

    P-channel CCD imagers, 200-300um thick, fully depleted, and back-illuminat ed are being developed for scientific applications including ground- and space-based astronomy and x-ray detection. These thick devices have extended IR response, good point-spread function (PSF) and excellent radiation tolerance. Initially, these CCDs were made in-house at LBNL using 100 mm diameter wafers. Fabrication on high-resistivity 150 mm wafers is now proceeding according to a model in which the wafers are fir...

  20. CCD high-speed videography system with new concepts and techniques

    Science.gov (United States)

    Zheng, Zengrong; Zhao, Wenyi; Wu, Zhiqiang

    1997-05-01

    A novel CCD high speed videography system with brand-new concepts and techniques is developed by Zhejiang University recently. The system can send a series of short flash pulses to the moving object. All of the parameters, such as flash numbers, flash durations, flash intervals, flash intensities and flash colors, can be controlled according to needs by the computer. A series of moving object images frozen by flash pulses, carried information of moving object, are recorded by a CCD video camera, and result images are sent to a computer to be frozen, recognized and processed with special hardware and software. Obtained parameters can be displayed, output as remote controlling signals or written into CD. The highest videography frequency is 30,000 images per second. The shortest image freezing time is several microseconds. The system has been applied to wide fields of energy, chemistry, medicine, biological engineering, aero- dynamics, explosion, multi-phase flow, mechanics, vibration, athletic training, weapon development and national defense engineering. It can also be used in production streamline to carry out the online, real-time monitoring and controlling.

  1. Housing And Mounting Structure

    Science.gov (United States)

    Anderson, Gene R.; Armendariz, Marcelino G.; Baca, Johnny R.F.; Bryan, Robert P.; Carson, Richard F.; Duckett, III, Edwin B.; McCormick, Frederick B.; Miller, Gregory V.; Peterson, David W.; Smith, Terrance T.

    2005-03-08

    This invention relates to an optical transmitter, receiver or transceiver module, and more particularly, to an apparatus for connecting a first optical connector to a second optical connector. The apparatus comprises: (1) a housing having at least a first end and at least a second end, the first end of the housing capable of receiving the first optical connector, and the second end of the housing capable of receiving the second optical connector; (2) a longitudinal cavity extending from the first end of the housing to the second end of the housing; and (3) an electromagnetic shield comprising at least a portion of the housing. This invention also relates to an apparatus for housing a flexible printed circuit board, and this apparatus comprises: (1) a mounting structure having at least a first surface and a second surface; (2) alignment ridges along the first and second surfaces of the mounting structure, the alignment ridges functioning to align and secure a flexible printed circuit board that is wrapped around and attached to the first and second surfaces of the mounting structure; and (3) a series of heat sink ridges adapted to the mounting structure, the heat sink ridges functioning to dissipate heat that is generated from the flexible printed circuit board.

  2. A comparison between robotic-assisted laparoscopic distal pancreatectomy versus laparoscopic distal pancreatectomy.

    Science.gov (United States)

    Goh, Brian K P; Chan, Chung Yip; Soh, Hui-Ling; Lee, Ser Yee; Cheow, Peng-Chung; Chow, Pierce K H; Ooi, London L P J; Chung, Alexander Y F

    2017-03-01

    This study aims to compare the early perioperative outcomes of robotic-assisted laparoscopic distal pancreatectomy (RDP) versus laparoscopic distal pancreatectomy (LDP). The clinicopathologic features of 45 consecutive patients who underwent minimally-invasive distal pancreatectomy from 2006 to 2015 were retrospectively reviewed. Thirty-nine patients who met our study criteria were included. Eight patients underwent RDP and 31 had LDP. There were 10 (25.6%) open conversions. Six (15.4%) patients had major (> grade 2) morbidities and there was no in-hospital mortality. There were 14 (35.9%) grade A and 9 (23.1%) grade B pancreatic fistulas. Comparison between RDP and LDP demonstrated no significant difference between the patients' baseline characteristics except there was increased frequency of spleen-preserving pancreatectomies (3 (37.5%) vs 25 (80.6%), P=0.016) and splenic-vessel preservation (5 (62.5%) vs 4 (12.9%), P=0.003) in RDP. Comparison between outcomes demonstrated that RDP was associated with a longer median operation time (452.5 (range, 300-685) vs 245 min (range, 85-430), P=0.001) and increased frequency of the procedure completed purely laparoscopically (8 (100%) vs 18 (58.1%), P=0.025). RDP can be safely adopted and is equivalent to LDP in most perioperative outcomes. It is also associated with a decreased frequency of the need for hand-assistance laparoscopic surgery or open conversion but needed a longer operation time. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Caracterização espectral de áreas de gramíneas forrageiras infectadas com a doença "mela-das-sementes da braquiária" por meio de imagens CCD/CBERS-2 Spectral characterization of forage grasses infected with the disease "mela-das-sementes da braquiária" through CCD/CDBERS -2 images

    Directory of Open Access Journals (Sweden)

    José C. Rosatti

    2006-12-01

    Full Text Available Imagens CCD/CBERS-2, nas bandas espectrais CCD2, CCD3 e CCD4, dos anos de 2004 e 2005, de Mirante do Paranapanema - SP, foram transformadas em reflectância de superfície usando o modelo 5S de correção atmosférica e normalizadas radiometricamente. O objetivo principal foi caracterizar espectralmente áreas de pastagens de Brachiaria brizantha em fase de florescimento, isentas e infectadas com a doença "mela-das-sementes da braquiária", possibilitando a sua detecção por meio da comparação entre os valores de reflectância de superfície denominada de Fator de Reflectância Bidirecional de Superfície (FRBS. Teve-se, também, o objetivo de avaliar a eficácia das imagens CCD/CBERS-2 para a obtenção de respostas espectrais de pastagens. Os dosséis sadios e doentes da Brachiaria brizantha foram identificados por meio da análise dos valores de reflectância e dos dados observados no Índice de Estresse Hídrico Acumulativo Relativo da Cultura (ACWSI obtidos na área de estudo. Os resultados indicaram que as principais diferenças foram a diminuição da reflectância na banda CCD3 e o aumento da reflectância na banda CCD4 nas áreas doentes. A metodologia empregada com o uso de dados do sensor CCD/CBERS-2, associados ao ACWSI, mostrou-se eficaz para discriminar dosséis infectados com a "mela-das-sementes da braquiária".CCD/CBERS-2 images in the spectral bands of CCD2, CCD3 and CCD4 of the years 2004 and 2005, from Mirante do Paranapanema - SP (Brazil, were transformed into surface reflectance images using the 5S atmospheric correction model and radiometrically normalized. The main objective was to spectrally characterize pastures of Brachiaria brizantha in the flowering phase, exempt and infected with the disease "mela-das-sementes da braquiária" making it possible its detection through the comparison among the SBRF - Surface Bidirectional Reflectance Factor values. At the same time, it was aimed to evaluate the effectiveness of the

  4. A New Orthodontic Appliance with a Mini Screw for Upper Molar Distalization.

    Science.gov (United States)

    Ozkalayci, Nurhat; Yetmez, Mehmet

    2016-01-01

    The aim of this study is to present a new upper molar distalization appliance called Cise distalizer designed as intraoral device supported with orthodontic mini screw for upper permanent molar distalization. The new appliance consists of eight main components. In order to understand the optimum force level, the appliance under static loading is tested by using strain gage measurement techniques. Results show that one of the open coils produces approximately 300 gr distalization force. Cise distalizer can provide totally 600 gr distalization force. This range of force level is enough for distalization of upper first and second molar teeth.

  5. CCD photometry of Cepheid sequences in four nearby galaxies

    International Nuclear Information System (INIS)

    Metcalfe, N.; Shanks, T.

    1991-01-01

    We present Isaac Newton Telescope B and V CCD observations of deep photometric sequences in the vicinity of Cepheid variable stars in three nearby galaxies - M31, M33 and NGC 2403. We have also checked the photometry of the brightest stars in M81 and its dwarf companion, Holmberg IX. We use our data, combined with other recent results, to re-analyse the Cepheid distances to these galaxies. (author)

  6. Laparoscopic versus open distal pancreatectomy for pancreatic cancer.

    Science.gov (United States)

    Riviere, Deniece; Gurusamy, Kurinchi Selvan; Kooby, David A; Vollmer, Charles M; Besselink, Marc G H; Davidson, Brian R; van Laarhoven, Cornelis J H M

    2016-04-04

    Surgical resection is currently the only treatment with the potential for long-term survival and cure of pancreatic cancer. Surgical resection is provided as distal pancreatectomy for cancers of the body and tail of the pancreas. It can be performed by laparoscopic or open surgery. In operations on other organs, laparoscopic surgery has been shown to reduce complications and length of hospital stay as compared with open surgery. However, concerns remain about the safety of laparoscopic distal pancreatectomy compared with open distal pancreatectomy in terms of postoperative complications and oncological clearance. To assess the benefits and harms of laparoscopic distal pancreatectomy versus open distal pancreatectomy for people undergoing distal pancreatectomy for pancreatic ductal adenocarcinoma of the body or tail of the pancreas, or both. We used search strategies to search the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, Science Citation Index Expanded and trials registers until June 2015 to identify randomised controlled trials (RCTs) and non-randomised studies. We also searched the reference lists of included trials to identify additional studies. We considered for inclusion in the review RCTs and non-randomised studies comparing laparoscopic versus open distal pancreatectomy in patients with resectable pancreatic cancer, irrespective of language, blinding or publication status.. Two review authors independently identified trials and independently extracted data. We calculated odds ratios (ORs), mean differences (MDs) or hazard ratios (HRs) along with 95% confidence intervals (CIs) using both fixed-effect and random-effects models with RevMan 5 on the basis of intention-to-treat analysis when possible. We found no RCTs on this topic. We included in this review 12 non-randomised studies that compared laparoscopic versus open distal pancreatectomy (1576 participants: 394 underwent laparoscopic distal pancreatectomy and 1182

  7. Measuring neutron fluences and gamma/x-ray fluxes with CCD cameras

    International Nuclear Information System (INIS)

    Yates, G.J.; Smith, G.W.; Zagarino, P.; Thomas, M.C.

    1991-01-01

    The capability to measure bursts of neutron fluences and gamma/x-ray fluxes directly with charge coupled device (CCD) cameras while being able to distinguish between the video signals produced by these two types of radiation, even when they occur simultaneously, has been demonstrated. Volume and area measurements of transient radiation-induced pixel charge in English Electric Valve (EEV) Frame Transfer (FT) charge coupled devices (CCDs) from irradiation with pulsed neutrons (14 MeV) and Bremsstrahlung photons (4--12 MeV endpoint) are utilized to calibrate the devices as radiometric imaging sensors capable of distinguishing between the two types of ionizing radiation. Measurements indicate ∼.05 V/rad responsivity with ≥1 rad required for saturation from photon irradiation. Neutron-generated localized charge centers or ''peaks'' binned by area and amplitude as functions of fluence in the 10 5 to 10 7 n/cm 2 range indicate smearing over ∼1 to 10% of CCD array with charge per pixel ranging between noise and saturation levels

  8. Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC[reg] film

    International Nuclear Information System (INIS)

    Lynch, Bart D.; Kozelka, Jakub; Ranade, Manisha K.; Li, Jonathan G.; Simon, William E.; Dempsey, James F.

    2006-01-01

    In this study, we present three significant artifacts that have the potential to negatively impact the accuracy and precision of film dosimetry measurements made using GAFCHROMIC[reg] EBT radiochromic film when read out with CCD flatbed scanners. Films were scanned using three commonly employed instruments: a Macbeth TD932 spot densitometer, an Epson Expression 1680 CCD array scanner, and a Microtek ScanMaker i900 CCD array scanner. For the two scanners we assessed the variation in optical density (OD) of GAFCHROMIC EBT film with scanning bed position, angular rotation of the film with respect to the scan line direction, and temperature inside the scanner due to repeated scanning. Scanning uniform radiochromic films demonstrated a distinct bowing effect in profiles in the direction of the CCD array with a nonuniformity of up to 17%. Profiles along a direction orthogonal to the CCD array demonstrated a 7% variation. A strong angular dependence was found in measurements made with the flatbed scanners; the effect could not be reproduced with the spot densitometer. An IMRT quality assurance film was scanned twice rotating the film 90 deg. between the scans. For films scanned on the Epson scanner, up to 12% variation was observed in unirradiated EBT films rotated between 0 deg. and 90 deg. , which decreased to approximately 8% for EBT films irradiated to 300 cGy. Variations of up to 80% were observed for films scanned with the Microtek scanner. The scanners were found to significantly increase the film temperature with repeated scanning. Film temperature between 18 and 33 deg. C caused OD changes of approximately 7%. Considering these effects, we recommend adherence to a strict scanning protocol that includes: maintaining the orientation of films scanned on flatbed scanners, limiting scanning to the central portion of the scanner bed, and limiting the number of consecutive scans to minimize changes in OD caused by film heating

  9. PECULIARITIES OF ASSIGNMENT OF ROLLING BEARING MOUNTING AND PARAMETERS OF GEOMETRIC ACCURACY OF MOUNTING SURFACES OF SHAFTS AND FRAMES

    Directory of Open Access Journals (Sweden)

    Adamenko Yu. І.

    2017-04-01

    Full Text Available The standards and methods concerning assignment of rolling bearing fit with shafts and frames via example of bearing 6-208 are analyzed. We set certain differences of recommendations according to GOST 3325-85, "Rolling bearings. Tolerance zones and technical requirements to mounting surfaces of shafts and frames. Attachment" and by reference of rolling bearing manufacturers. The following factors should be taken into consideration when assigning the mounting with the tension the internal ring of the bearing with shaft and mounting with a gap in the outer ring with a housing bore. The methods of achieving accuracy of mounting surfaces of shafts and frames via form tolerance assignment: roundness tolerance, profile of longitudinal cut, cross section, cylindricity and others. It is possible to limit the bearing rings in different ways, for example appointing the cylindrical mounting surfaces and bead end surfaces the appropriate tolerances, namely: coaxiality tolerance or full radial beat of mounting surfaces, and also perpendicularity tolerance, butt beats and full butt beats of mounting end surfaces. We suggest to expand methods of achieving the accuracy of shafts and frames depending on seriation of production and production operations metrology support.

  10. BVRI CCD photometry of Omega Centauri

    International Nuclear Information System (INIS)

    Alcaino, G.; Liller, W.

    1987-01-01

    Color-magnitude diagrams (CMDs) of V vs B-V, V vs V-I, and V vs B-I have been constructed based on 179 BVRI CCD frames of two adjoining 4x2.5-arcmin fields in Omega Cen (NGC 5139) obtained with the 1.54-m Danish La Silla telescope. The spread in the main sequences noted in the three CMDs indicates that the wide range in chemical composition among the evolved stars in this cluster persists as well in the unevolved stars. This result suggests that the abundance variations are primordial. A difference in magnitude between the turnoff and the horizontal branch of 3.8 + or - 0.15 is found which is greater than a previous value. 38 references

  11. CCD photometry of NGC 2419

    International Nuclear Information System (INIS)

    Christian, C.A.; Heasley, J.N.

    1988-01-01

    The properties of the globular cluster NGC 2419 are reexamined using CCD photometry deepened to the vicinity of the main-sequence turnoff. A new color-magnitude diagram is derived that extends to V = 24.5 mag. It is concluded that NGC 2419 is an outer-halo analog of the metal-poor globulars closer to the Galactic center. NGC 2419 is probably nearly the same age as M15 and differs only slightly, if at all, in metallicity. NGC 2419 has many similarities with the clusters NGC 5466, M15, and M92. Comparison of the data with the isochrones of VandenBerg and Bell (1985) implies a distance modulus of 20.1 with Delta (B-V) = 0.18 mag. Oxygen-rich models can be fit to the data; such a comparison yields a lower limit to the acceptable distance modulus of the cluster. 26 references

  12. A New Orthodontic Appliance with a Mini Screw for Upper Molar Distalization

    Directory of Open Access Journals (Sweden)

    Nurhat Ozkalayci

    2016-01-01

    Full Text Available The aim of this study is to present a new upper molar distalization appliance called Cise distalizer designed as intraoral device supported with orthodontic mini screw for upper permanent molar distalization. The new appliance consists of eight main components. In order to understand the optimum force level, the appliance under static loading is tested by using strain gage measurement techniques. Results show that one of the open coils produces approximately 300 gr distalization force. Cise distalizer can provide totally 600 gr distalization force. This range of force level is enough for distalization of upper first and second molar teeth.

  13. A FUNCTIONAL EVALUATION STUDY OF DISTAL FEMORAL FRACTURES FIXED WITH DISTAL FEMORAL LOCKING PLATE

    Directory of Open Access Journals (Sweden)

    Manikumar C. J

    2017-04-01

    Full Text Available BACKGROUND Fractures of the distal femur present considerable challenges in management. Older patients especially women sustain fractures due to osteoporosis. Supracondylar fractures of femur have a bimodal distribution. They account for 6% of all femur fractures and 31% if hip fractures were excluded. Nearly, 50% of distal femur intra-articular fractures are open fractures. Before 1970, most supracondylar fractures were treated nonoperatively; however, difficulties were often encountered including persistent angulatory deformity, knee joint incongruity, loss of knee motion and delayed mobilisation. The trend of open reduction and internal fixation has become evident in recent years with good results being obtained with AO blade plate, dynamic condylar screw, intramedullary supracondylar nail and locking compression plate. Elderly patients and osteoporosis pose difficulty in treating intra-articular fractures of the lower end of femur. Loss of stable fixation is of great concern in these cases. Hence, locking compression plate use has an advantage in these patients. MATERIALS AND METHODS In this study, 20 patients with closed fracture of distal femur were studied. All the cases were treated at the Department of Orthopaedics, Rangaraya Medical College/Government General Hospital, Kakinada, Andhra Pradesh, between November 2013 and November 2015. The method used for fracture fixation was open reduction and internal fixation with distal femoral locking plate. The duration of follow up ranged from 3 months to 24 months. All the fractures in this series were posttraumatic. The patients were functionally evaluated with Neer’s scoring system. 1 RESULTS Twenty distal femoral fractures were treated with distal femoral locking plates. 15 patients were males and 5 patients were females. The median age was 47 years ranging from 28-70 years. 16 of the fractures were caused by road traffic accidents and 2 were due to fall, 2 were due to assault. 12 patients

  14. A randomized controlled trial of cast versus splint for distal radial buckle fracture: an evaluation of satisfaction, convenience, and preference.

    Science.gov (United States)

    Williams, Kristine G; Smith, Gillian; Luhmann, Scott J; Mao, Jingnan; Gunn, Joseph D; Luhmann, Janet D

    2013-05-01

    Buckle fractures are inherently stable and at low risk for displacement. These advantages allow for treatment options that may create confusion for the practitioner. Accepted immobilization methods include circumferential cast, plaster or prefabricated splint, and soft bandaging. Despite mounting evidence for splinting, the questions of pain, preference, satisfaction, and convenience offer a challenge to changing practice. The purposes of this study were (1) to compare cast versus splint for distal radial buckle fractures in terms of parental and patient satisfaction, convenience, and preference and (2) to compare pain reported for cast versus splint. We conducted a prospective randomized trial of a convenience sample of patients 2 through 17 years with a radiologically confirmed distal radial buckle fracture. Subjects were randomly assigned to short-arm cast or prefabricated wrist splint. We assessed satisfaction, convenience, preference, and pain in the emergency department and at days 1, 3, 7, and 21 after immobilization. Ninety-four patients were enrolled. Compared with the cast group, those in the splint group reported higher levels of satisfaction, preference, and convenience on 10-point visual analog scale. Although pain scores were higher for those in the splint group, the difference was not statistically significant. With the exception of pain reported in the emergency department being higher for the splinted group, all other measures, including convenience, satisfaction, and preference, showed a clear trend favoring splints at almost every time period in the study. This study provides additional evidence that splinting is preferable to casting for the treatment of distal radial buckle fractures.

  15. Mounting support for a photovoltaic module

    Science.gov (United States)

    Brandt, Gregory Michael; Barsun, Stephan K.; Coleman, Nathaniel T.; Zhou, Yin

    2013-03-26

    A mounting support for a photovoltaic module is described. The mounting support includes a foundation having an integrated wire-way ledge portion. A photovoltaic module support mechanism is coupled with the foundation.

  16. Cost-effectiveness of laparoscopic versus open distal pancreatectomy for pancreatic cancer.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Riviere, Deniece; van Laarhoven, C J H; Besselink, Marc; Abu-Hilal, Mohammed; Davidson, Brian R; Morris, Steve

    2017-01-01

    A recent Cochrane review compared laparoscopic versus open distal pancreatectomy for people with for cancers of the body and tail of the pancreas and found that laparoscopic distal pancreatectomy may reduce the length of hospital stay. We compared the cost-effectiveness of laparoscopic distal pancreatectomy versus open distal pancreatectomy for pancreatic cancer. Model based cost-utility analysis estimating mean costs and quality-adjusted life years (QALYs) per patient from the perspective of the UK National Health Service. A decision tree model was constructed using probabilities, outcomes and cost data from published sources. A time horizon of 5 years was used. One-way and probabilistic sensitivity analyses were undertaken. The probabilistic sensitivity analysis showed that the incremental net monetary benefit was positive (£3,708.58 (95% confidence intervals (CI) -£9,473.62 to £16,115.69) but the 95% CI includes zero, indicating that there is significant uncertainty about the cost-effectiveness of laparoscopic distal pancreatectomy versus open distal pancreatectomy. The probability laparoscopic distal pancreatectomy was cost-effective compared to open distal pancreatectomy for pancreatic cancer was between 70% and 80% at the willingness-to-pay thresholds generally used in England (£20,000 to £30,000 per QALY gained). Results were sensitive to the survival proportions and the operating time. There is considerable uncertainty about whether laparoscopic distal pancreatectomy is cost-effective compared to open distal pancreatectomy for pancreatic cancer in the NHS setting.

  17. Ultraviolet downconverting phosphor for use with silicon CCD imagers

    Science.gov (United States)

    Blouke, M. M.; Cowens, M. W.; Hall, J. E.; Westphal, J. A.; Christensen, A. B.

    1980-01-01

    The properties and application of a UV downconverting phosphor (coronene) to silicon charge coupled devices are discussed. Measurements of the absorption spectrum have been extended to below 1000 A, and preliminary results indicate the existence of useful response to at least 584 A. The average conversion efficiency of coronene was measured to be approximately 20% at 2537 A. Imagery at 3650 A using a backside illuminated 800 x 800 CCD coated with coronene is presented.

  18. Characterization of a 512x512-pixel 8-output full-frame CCD for high-speed imaging

    Science.gov (United States)

    Graeve, Thorsten; Dereniak, Eustace L.

    1993-01-01

    The characterization of a 512 by 512 pixel, eight-output full frame CCD manufactured by English Electric Valve under part number CCD13 is discussed. This device is a high- resolution Silicon-based array designed for visible imaging applications at readout periods as low as two milliseconds. The characterization of the device includes mean-variance analysis to determine read noise and dynamic range, as well as charge transfer efficiency, MTF, and quantum efficiency measurements. Dark current and non-uniformity issues on a pixel-to-pixel basis and between individual outputs are also examined. The characterization of the device is restricted by hardware limitations to a one MHz pixel rate, corresponding to a 40 ms readout time. However, subsections of the device have been operated at up to an equivalent 100 frames per second. To maximize the frame rate, the CCD is illuminated by a synchronized strobe flash in between frame readouts. The effects of the strobe illumination on the imagery obtained from the device is discussed.

  19. Traumatic Distal Ulnar Artery Thrombosis

    Directory of Open Access Journals (Sweden)

    Ahmet A. Karaarslan

    2014-01-01

    Full Text Available This paper is about a posttraumatic distal ulnar artery thrombosis case that has occurred after a single blunt trauma. The ulnar artery thrombosis because of chronic trauma is a frequent condition (hypothenar hammer syndrome but an ulnar artery thrombosis because of a single direct blunt trauma is rare. Our patient who has been affected by a single blunt trauma to his hand and developed ulnar artery thrombosis has been treated by resection of the thrombosed ulnar artery segment. This report shows that a single blunt trauma can cause distal ulnar artery thrombosis in the hand and it can be treated merely by thrombosed segment resection in suitable cases.

  20. Distinct subclassification of DRG neurons innervating the distal colon and glans penis/distal urethra based on the electrophysiological current signature.

    Science.gov (United States)

    Rau, Kristofer K; Petruska, Jeffrey C; Cooper, Brian Y; Johnson, Richard D

    2014-09-15

    Spinal sensory neurons innervating visceral and mucocutaneous tissues have unique microanatomic distribution, peripheral modality, and physiological, pharmacological, and biophysical characteristics compared with those neurons that innervate muscle and cutaneous tissues. In previous patch-clamp electrophysiological studies, we have demonstrated that small- and medium-diameter dorsal root ganglion (DRG) neurons can be subclassified on the basis of their patterns of voltage-activated currents (VAC). These VAC-based subclasses were highly consistent in their action potential characteristics, responses to algesic compounds, immunocytochemical expression patterns, and responses to thermal stimuli. For this study, we examined the VAC of neurons retrogradely traced from the distal colon and the glans penis/distal urethra in the adult male rat. The afferent population from the distal colon contained at least two previously characterized cell types observed in somatic tissues (types 5 and 8), as well as four novel cell types (types 15, 16, 17, and 18). In the glans penis/distal urethra, two previously described cell types (types 6 and 8) and three novel cell types (types 7, 14, and 15) were identified. Other characteristics, including action potential profiles, responses to algesic compounds (acetylcholine, capsaicin, ATP, and pH 5.0 solution), and neurochemistry (expression of substance P, CGRP, neurofilament, TRPV1, TRPV2, and isolectin B4 binding) were consistent for each VAC-defined subgroup. With identification of distinct DRG cell types that innervate the distal colon and glans penis/distal urethra, future in vitro studies related to the gastrointestinal and urogenital sensory function in normal as well as abnormal/pathological conditions may be benefitted. Copyright © 2014 the American Physiological Society.

  1. Nonunions of the distal tibia treated by reamed intramedullary nailing

    NARCIS (Netherlands)

    Richmond, Jeffrey; Colleran, Kevin; Borens, Olivier; Kloen, Peter; Helfet, David L.

    2004-01-01

    The purpose of this study is to determine the efficacy of reamed intramedullary nailing in the treatment of nonunions of the distal one-fourth of the tibia. Nonunions of the distal tibia are particularly difficult to treat given the short distal segment, the proximity to the ankle joint, and the

  2. CCD linear image sensor ILX511 arrangment for a technical spectrometer

    Czech Academy of Sciences Publication Activity Database

    Bartoněk, L.; Keprt, Jiří; Vlček, Martin

    2003-01-01

    Roč. 33, 2-3 (2003), s. 548-553 ISSN 0078-5466 Institutional research plan: CEZ:AV0Z1010921 Keywords : CCD linear sensor ILX511 * enhanced parallel port (EPP able IEEE1284) * A/D converter AD9280 Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.221, year: 2003

  3. Systems and methods for mirror mounting with minimized distortion

    Science.gov (United States)

    Antonille, Scott R. (Inventor); Wallace, Thomas E. (Inventor); Content, David A. (Inventor); Wake, Shane W. (Inventor)

    2012-01-01

    A method for mounting a mirror for use in a telescope includes attaching the mirror to a plurality of adjustable mounts; determining a distortion in the mirror caused by the plurality adjustable mounts, and, if the distortion is determined to be above a predetermined level: adjusting one or more of the adjustable mounts; and determining the distortion in the mirror caused by the adjustable mounts; and in the event the determined distortion is determined to be at or below the predetermined level, rigidizing the adjustable mounts.

  4. Computer-aided diagnosis of pneumoconiosis abnormalities extracted from chest radiographs scanned with a CCD scanner

    International Nuclear Information System (INIS)

    Abe, Koji; Minami, Masahide; Nakamura, Munehiro

    2011-01-01

    This paper presents a computer-aided diagnosis for pneumoconiosis radiographs obtained with a common charge-coupled devices (CCD) scanner. Since the current computer-aided diagnosis systems of pneumoconiosis are not practical for medical doctors due to high costs of usage for a special scanner, we propose a novel system which measures abnormalities of pneumoconiosis from lung images obtained with a common CCD scanner. Experimental results of discriminations between normal and abnormal cases for 56 right-lung images including 6 standard pneumoconiosis images have shown that the proposed abnormalities are well extracted according to the standards of pneumoconiosis categories. (author)

  5. Atmospheric radiation environment analyses based-on CCD camera at various mountain altitudes and underground sites

    Directory of Open Access Journals (Sweden)

    Li Cavoli Pierre

    2016-01-01

    Full Text Available The purpose of this paper is to discriminate secondary atmospheric particles and identify muons by measuring the natural radiative environment in atmospheric and underground locations. A CCD camera has been used as a cosmic ray sensor. The Low Noise Underground Laboratory of Rustrel (LSBB, France gives the access to a unique low-noise scientific environment deep enough to ensure the screening from the neutron and proton radiative components. Analyses of the charge levels in pixels of the CCD camera induced by radiation events and cartographies of the charge events versus the hit pixel are proposed.

  6. Assessment of space proton radiation-induced charge transfer inefficiency in the CCD204 for the Euclid space observatory

    International Nuclear Information System (INIS)

    Gow, J P D; Murray, N J; Holland, A D; Hall, D J; Cropper, M; Burt, D; Hopkinson, G; Duvet, L

    2012-01-01

    Euclid is a medium class European Space Agency mission candidate for launch in 2019 with a primary goal to study the dark universe using the weak lensing and baryonic acoustic oscillations techniques. Weak lensing depends on accurate shape measurements of distant galaxies. Therefore it is beneficial that the effects of radiation-induced charge transfer inefficiency (CTI) in the Euclid CCDs over the course of the 5 year mission at L2 are understood. This will allow, through experimental analysis and modelling techniques, the effects of radiation induced CTI on shape to be decoupled from those of mass inhomogeneities along the line-of-sight. This paper discusses a selection of work from the study that has been undertaken using the e2v CCD204 as part of the initial proton radiation damage assessment for Euclid. The experimental arrangement and procedure are described followed by the results obtained, thereby allowing recommendations to be made on the CCD operating temperature, to provide an insight into CTI effects using an optical background, to assess the benefits of using charge injection on CTI recovery and the effect of the use of two different methods of serial clocking on serial CTI. This work will form the basis of a comparison with a p-channel CCD204 fabricated using the same mask set as the n-channel equivalent. A custom CCD has been designed, based on this work and discussions between e2v technologies plc. and the Euclid consortium, and designated the CCD273.

  7. Technical preparation of the Yuzhteploehnergomontazh trust for technological equipment mounting

    International Nuclear Information System (INIS)

    Zayats, A.I.

    1982-01-01

    Measures of technical preparation for equipment mounting at the Zaporozhe NPP developed with the Yuzhteploehnergomontazh trust experts are considered. These measures envisage the construction of mounting base of heat facilities, calculation of labour contents and determination of necessary quantity of mounters, development of optimal flowsheet of mounting control, improvement of mounting qualification and creation of stable collective body, improvement of technical level of mounting and welding works, organizational-technical measures on mounting logistics. Factors affecting negatively technical preparation quality of equipment mounting at the Zaporozhe NPP are discussed. The flowsheet of mounting control is presented

  8. The astro-geodetic use of CCD for gravity field refinement

    Science.gov (United States)

    Gerstbach, G.

    1996-07-01

    The paper starts with a review of geoid projects, where vertical deflections are more effective than gravimetry. In alpine regions the economy of astrogeoids is at least 10 times higher, but many countries do not make use of this fact - presumably because the measurements are not fully automated up to now. Based upon the experiences of astrometry of high satellites and own tests the author analyses the use of CCD for astro-geodetic measurements. Automation and speeding up will be possible in a few years, the latter depending on the observation scheme. Sensor characteristics, cooling and reading out of the devices should be harmonized. Using line sensors in small prism astrolabes, the CCD accuracy will reach the visual one (±0.2″) within 5-10 years. Astrogeoids can be combined ideally with geological data, because vertical variation of rock densities does not cause systematic effects (contrary to gravimetry). So a geoid of ±5 cm accuracy (achieved in Austria and other alpine countries by 5-10 points per 1000 km 2) can be improved to ±2 cm without additional observations and border effects.

  9. Combat vehicle crew helmet-mounted display: next generation high-resolution head-mounted display

    Science.gov (United States)

    Nelson, Scott A.

    1994-06-01

    The Combat Vehicle Crew Head-Mounted Display (CVC HMD) program is an ARPA-funded, US Army Natick Research, Development, and Engineering Center monitored effort to develop a high resolution, flat panel HMD for the M1 A2 Abrams main battle tank. CVC HMD is part of the ARPA High Definition Systems (HDS) thrust to develop and integrate small (24 micrometers square pels), high resolution (1280 X 1024 X 6-bit grey scale at 60 frame/sec) active matrix electroluminescent (AMEL) and active matrix liquid crystal displays (AMLCD) for head mounted and projection applications. The Honeywell designed CVC HMD is a next generation head-mounted display system that includes advanced flat panel image sources, advanced digital display driver electronics, high speed (> 1 Gbps) digital interconnect electronics, and light weight, high performance optical and mechanical designs. The resulting dramatic improvements in size, weight, power, and cost have already led to program spin offs for both military and commercial applications.

  10. Puesta en marcha de un microdensitómetro automático basado en CCD

    Science.gov (United States)

    Calderón, J. H.; Bustos Fierro, I. H.

    We present the commisioning of a CCD-based microdensitometer intended to perform astrometric measurements of photographic plates. The work done consisted in the installation of a CCD camera, the modification of the motion system, the construction of a new illumination device, the adaptation of the electronics, and the development of software. The instrument is intended to be used for the astrometric measurement mainly of plates of the Astrographic Catalog and Carte du Ciel collections from Córdoba Observatory. In this phase of the project we counted with the collaboration of the Instituto Provincial de Enseñanza Media No 59, 25 de Mayo, Cruz Alta (Province of Córdoba). The origin and importance of such collaboration is commented.

  11. Radiation damage of the PCO Pixelfly VGA CCD camera of the BES system on KSTAR tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Náfrádi, Gábor, E-mail: nafradi@reak.bme.hu [NTI, BME, EURATOM Association, H-1111 Budapest (Hungary); Kovácsik, Ákos, E-mail: kovacsik.akos@reak.bme.hu [NTI, BME, EURATOM Association, H-1111 Budapest (Hungary); Pór, Gábor, E-mail: por@reak.bme.hu [NTI, BME, EURATOM Association, H-1111 Budapest (Hungary); Lampert, Máté, E-mail: lampert.mate@wigner.mta.hu [Wigner RCP, RMI, EURATOM Association, POB 49, 1525 Budapest (Hungary); Un Nam, Yong, E-mail: yunam@nfri.re.kr [NFRI, 169-148 Gwahak-Ro, Yuseong-Gu, Daejeon 305-806 (Korea, Republic of); Zoletnik, Sándor, E-mail: zoletnik.sandor@wigner.mta.hu [Wigner RCP, RMI, EURATOM Association, POB 49, 1525 Budapest (Hungary)

    2015-01-11

    A PCO Pixelfly VGA CCD camera which is part a of the Beam Emission Spectroscopy (BES) diagnostic system of the Korea Superconducting Tokamak Advanced Research (KSTAR) used for spatial calibrations, suffered from serious radiation damage, white pixel defects have been generated in it. The main goal of this work was to identify the origin of the radiation damage and to give solutions to avoid it. Monte Carlo N-Particle eXtended (MCNPX) model was built using Monte Carlo Modeling Interface Program (MCAM) and calculations were carried out to predict the neutron and gamma-ray fields in the camera position. Besides the MCNPX calculations pure gamma-ray irradiations of the CCD camera were carried out in the Training Reactor of BME. Before, during and after the irradiations numerous frames were taken with the camera with 5 s long exposure times. The evaluation of these frames showed that with the applied high gamma-ray dose (1.7 Gy) and dose rate levels (up to 2 Gy/h) the number of the white pixels did not increase. We have found that the origin of the white pixel generation was the neutron-induced thermal hopping of the electrons which means that in the future only neutron shielding is necessary around the CCD camera. Another solution could be to replace the CCD camera with a more radiation tolerant one for example with a suitable CMOS camera or apply both solutions simultaneously.

  12. CCD Photometry of W UMa Type Binary TY UMa

    Directory of Open Access Journals (Sweden)

    Young Woon Kang

    2001-06-01

    Full Text Available We present VRI CCD photometry of W UMa type binary TY UMa. The light curves show that the secondary minimum is deeper than theprimary minimum and the maximum I (0.p25 is 0.m023 brighter than the maximum II (0.p75. The V light curve has beenanalyzed and the photometric solutions have been determined by the method of Wilson & Devinney differential correction. Weadopted the spot model to explain the asymetric light curve.

  13. A CCD fitted to the UV Prime spectrograph: Performance

    International Nuclear Information System (INIS)

    Boulade, O.

    1986-10-01

    A CCD camera was fitted to the 3.6 m French-Canadian telescope in Hawai. Performance of the system and observations of elliptic galaxies (stellar content and galactic evolution in a cluster) and quasars (absorption lines in spectra) are reported. In spite of its resolution being only average, the extremely rapid optics of the UV spectrograph gives good signal to noise ratios enabling redshifts and velocity scatter to be calculated with an accuracy better than 30 km/sec [fr

  14. Improving the resolution in soft X-ray emission spectrometers through photon-counting using an Electron Multiplying CCD

    International Nuclear Information System (INIS)

    Hall, D J; Soman, M; Tutt, J; Murray, N; Holland, A; Schmitt, T; Raabe, J; Strocov, V N; Schmitt, B

    2012-01-01

    In 2007, a study of back-illuminated Charge-Coupled Devices (CCDs) for soft X-ray photon detection demonstrated the improvements that could be brought over more traditional micro-channel plate detectors for X-ray spectrometers based on diffraction gratings and position sensitive detectors. Whilst the spatial resolution was reported to be improved dramatically, an intrinsic limit of approximately 25 micrometers was found due to the spreading of the charge cloud generated in the CCD across several pixels. To overcome this resolution limit, it is necessary to move away from the current integrated imaging methods and consider a photon-counting approach, recording the photon interaction locations to the sub-pixel level. To make use of photon-counting techniques it is important that the individual events are separable. To maintain the throughput of the spectrometer for high intensity lines, higher frame rates and therefore higher readout speeds are required. With CCD based systems, the increased noise at high readout speeds can limit the photon-counting performance. The Electron-Multiplying CCD shares a similar architecture with the standard CCD but incorporates a g ain register . This novel addition allows controllable gain to be applied to the signal before the read noise is introduced, therefore allowing individual events to be resolved above the noise even at much higher readout rates. In the past, the EM-CCD has only been available with imaging areas too small to be practical in soft X-ray emission spectrometers. The current drive for large area Electron-Multiplying CCDs is opening this technology to new photon-counting applications, requiring in-depth analysis of the processes and techniques involved. Early results indicate that through the introduction of photon-counting techniques the resolution in such systems can be dramatically improved.

  15. Mounting and Alignment of IXO Mirror Segments

    Science.gov (United States)

    Chan, Kai-Wing; Zhang, William; Evans, Tyler; McClelland, Ryan; Hong, Melinda; Mazzarella, James; Saha, Timo; Jalota, Lalit; Olsen, Lawrence; Byron, Glenn

    2010-01-01

    A suspension-mounting scheme is developed for the IXO (International X-ray Observatory) mirror segments in which the figure of the mirror segment is preserved in each stage of mounting. The mirror, first fixed on a thermally compatible strongback, is subsequently transported, aligned and transferred onto its mirror housing. In this paper, we shall outline the requirement, approaches, and recent progress of the suspension mount processes.

  16. 14 CFR 33.23 - Engine mounting attachments and structure.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Engine mounting attachments and structure... mounting attachments and structure. (a) The maximum allowable limit and ultimate loads for engine mounting attachments and related engine structure must be specified. (b) The engine mounting attachments and related...

  17. 76 FR 76689 - Cibola National Forest, Mount Taylor Ranger District, NM, Mount Taylor Combined Exploratory Drilling

    Science.gov (United States)

    2011-12-08

    ... National Forest, Mount Taylor Ranger District, NM, Mount Taylor Combined Exploratory Drilling AGENCY... proposed action is to approve two Plans of Operations for exploratory uranium drilling on the Cibola... San Mateo. In total, there are up to 279 drill holes that would be drilled over a period not to exceed...

  18. Researchers develop CCD image sensor with 20ns per row parallel readout time

    CERN Multimedia

    Bush, S

    2004-01-01

    "Scientists at the Rutherford Appleton Laboratory (RAL) in Oxfordshire have developed what they claim is the fastest CCD (charge-coupled device) image sensor, with a readout time which is 20ns per row" (1/2 page)

  19. Roentgenographic evaluation of the actual CCD and AT angle. Pt. 2

    International Nuclear Information System (INIS)

    Brueckl, R.; Grunert, S.; Rosemeyer, B.

    1986-01-01

    The method developed by Rippstein and Mueller allows a mathematically exact determination of the femoral neck-shaft angle (CCD) and the angle of torsion (AT); already at a deviation of 5-10 0 from the prescribed position of the patient considerable errors (up to more than 15 0 ) may occur. For this reason two alternative methods are cited and described in detail: a) the cinematographic determination of the CCD- and AT-angle according to Schwetlick, and b) the combination of the determination of the AT-angle in exterior rotation according to Rogers and an anteroposterior roentgenogram of the pelvis and hips in interior rotation of the size of the AT-angle. Both methods are also mathematically exact, however, in addition almost independent from minor deviations in the position of the patient. It is advisable to apply one of the cited methods in cases of high AT-angle values (>>30 0 ), in cases where the placing of the patient is difficult and where the determination of the angles would require a major therapeutic measurement. (orig.) [de

  20. An optical test bench for the precision characterization of absolute quantum efficiency for the TESS CCD detectors

    International Nuclear Information System (INIS)

    Krishnamurthy, A.; Villasenor, J.; Kissel, S.; Ricker, G.; Vanderspek, R.

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) will search for planets transiting bright stars with Ic ∼< 13. TESS has been selected by NASA for launch in 2018 as an Astrophysics Explorer mission, and is expected to discover a thousand or more planets that are smaller in size than Neptune. TESS will employ four wide-field optical charge-coupled device (CCD) cameras with a band-pass of 650 nm–1050 nm to detect temporary drops in brightness of stars due to planetary transits. The 1050 nm limit is set by the quantum efficiency (QE) of the CCDs. The detector assembly consists of four back-illuminated MIT Lincoln Laboratory CCID-80 devices. Each CCID-80 device consists of 2048×2048 imaging array and 2048×2048 frame store regions. Very precise on-ground calibration and characterization of CCD detectors will significantly assist in the analysis of the science data obtained in space. The characterization of the absolute QE of the CCD detectors is a crucial part of the characterization process because QE affects the performance of the CCD significantly over the redder wavelengths at which TESS will be operating. An optical test bench with significantly high photometric stability has been developed to perform precise QE measurements. The design of the test setup along with key hardware, methodology, and results from the test campaign are presented.

  1. The role of imaging in diagnosing diseases of the distal radioulnar joint, triangular fibrocartilage complex, and distal ulna.

    Science.gov (United States)

    Squires, Judy H; England, Eric; Mehta, Kaushal; Wissman, Robert D

    2014-07-01

    The purpose of this article is to review the anatomy, biomechanics, and multimodality imaging findings of common and uncommon distal radioulnar joint (DRUJ), triangular fibrocartilage complex, and distal ulna abnormalities. The DRUJ is a common site for acute and chronic injuries and is frequently imaged to evaluate chronic wrist pain, forearm dysfunction, and traumatic forearm injury. Given the complex anatomy of the wrist, the radiologist plays a vital role in the diagnosis of wrist pain and dysfunction.

  2. Minimally invasive percutaneous plate fixation of distal tibia fractures.

    LENUS (Irish Health Repository)

    Bahari, Syah

    2007-10-01

    We report a series of 42 patients reviewed at a mean of 19.6 months after treatment of distal tibial and pilon fractures using the AO distal tibia locking plate with a minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. Mean time to union was 22.4 weeks. All fractures united with acceptable alignment and angulation. Two cases of superficial infection were noted, with one case of deep infection. Mean SF36 score was 85 and mean AOFAS score was 90 at a mean of 19 months follow-up. We report satisfactory outcomes with the use of the AO distal tibia locking plate in treatment of unstable distal tibial fractures. Eighty-nine percent of the patients felt that they were back to their pre injury status and 95% back to their previous employment.

  3. Optimal CCD readout by digital correlated double sampling

    Science.gov (United States)

    Alessandri, C.; Abusleme, A.; Guzman, D.; Passalacqua, I.; Alvarez-Fontecilla, E.; Guarini, M.

    2016-01-01

    Digital correlated double sampling (DCDS), a readout technique for charge-coupled devices (CCD), is gaining popularity in astronomical applications. By using an oversampling ADC and a digital filter, a DCDS system can achieve a better performance than traditional analogue readout techniques at the expense of a more complex system analysis. Several attempts to analyse and optimize a DCDS system have been reported, but most of the work presented in the literature has been experimental. Some approximate analytical tools have been presented for independent parameters of the system, but the overall performance and trade-offs have not been yet modelled. Furthermore, there is disagreement among experimental results that cannot be explained by the analytical tools available. In this work, a theoretical analysis of a generic DCDS readout system is presented, including key aspects such as the signal conditioning stage, the ADC resolution, the sampling frequency and the digital filter implementation. By using a time-domain noise model, the effect of the digital filter is properly modelled as a discrete-time process, thus avoiding the imprecision of continuous-time approximations that have been used so far. As a result, an accurate, closed-form expression for the signal-to-noise ratio at the output of the readout system is reached. This expression can be easily optimized in order to meet a set of specifications for a given CCD, thus providing a systematic design methodology for an optimal readout system. Simulated results are presented to validate the theory, obtained with both time- and frequency-domain noise generation models for completeness.

  4. Programmable Clock Waveform Generation for CCD Readout

    Energy Technology Data Exchange (ETDEWEB)

    Vicente, J. de; Castilla, J.; Martinez, G.; Marin, J.

    2006-07-01

    Charge transfer efficiency in CCDs is closely related to the clock waveform. In this paper, an experimental framework to explore different FPGA based clock waveform generator designs is described. Two alternative design approaches for controlling the rise/fall edge times and pulse width of the CCD clock signal have been implemented: level-control and time-control. Both approaches provide similar characteristics regarding the edge linearity and noise. Nevertheless, dissimilarities have been found with respect to the area and frequency range of application. Thus, while the time-control approach consumes less area, the level control approach provides a wider range of clock frequencies since it does not suffer capacitor discharge effect. (Author) 8 refs.

  5. Cost-effectiveness of laparoscopic versus open distal pancreatectomy for pancreatic cancer

    NARCIS (Netherlands)

    Gurusamy, Kurinchi Selvan; Riviere, Deniece; van Laarhoven, C. J. H.; Besselink, Marc; Abu-Hilal, Mohammed; Davidson, Brian R.; Morris, Steve

    2017-01-01

    A recent Cochrane review compared laparoscopic versus open distal pancreatectomy for people with for cancers of the body and tail of the pancreas and found that laparoscopic distal pancreatectomy may reduce the length of hospital stay. We compared the cost-effectiveness of laparoscopic distal

  6. Multiband CCD Image Compression for Space Camera with Large Field of View

    Directory of Open Access Journals (Sweden)

    Jin Li

    2014-01-01

    Full Text Available Space multiband CCD camera compression encoder requires low-complexity, high-robustness, and high-performance because of its captured images information being very precious and also because it is usually working on the satellite where the resources, such as power, memory, and processing capacity, are limited. However, the traditional compression approaches, such as JPEG2000, 3D transforms, and PCA, have the high-complexity. The Consultative Committee for Space Data Systems-Image Data Compression (CCSDS-IDC algorithm decreases the average PSNR by 2 dB compared with JPEG2000. In this paper, we proposed a low-complexity compression algorithm based on deep coupling algorithm among posttransform in wavelet domain, compressive sensing, and distributed source coding. In our algorithm, we integrate three low-complexity and high-performance approaches in a deeply coupled manner to remove the spatial redundant, spectral redundant, and bit information redundancy. Experimental results on multiband CCD images show that the proposed algorithm significantly outperforms the traditional approaches.

  7. Mounting apparatus for a nozzle guide vane assembly

    Science.gov (United States)

    Boyd, Gary L.; Shaffer, James E.

    1995-01-01

    The present invention provides a ceramic nozzle guide assembly with an apparatus for mounting it to a metal nozzle case that includes an intermediate ceramic mounting ring. The mounting ring includes a plurality of projections that are received within a plurality of receptacles formed in the nozzle case. The projections of the mounting ring are secured within the receptacles by a ceramic retainer that allows contact between the two components only along arcuate surfaces thus eliminating sliding contact between the components.

  8. [Comparison of laparoscopic distal pancreatectomy and open distal pancreatectomy in pancreatic ductal adenocarcinoma].

    Science.gov (United States)

    Xu, K; Su, J J; Su, M; Yan, L; Feng, J; Xin, X L; Chen, Y L

    2017-10-23

    Objective: To compare and evaluate the curative effect of laparoscopic distal pancreatectomy(LDP) and traditional open distal pancreatectomy(ODP) in pancreatic ductal adenocarcinoma. Methods: The clinical data of 15 patients treated by LDP and 87 contemporaneous cases treated by ODP from January 2010 to November 2015 was collected, and the curative effect and prognosis of these patients were retrospectively analyzed. Results: The operation time of LDP group was (286.5±48.1) min, significantly longer than that of OPD group(226.6±56.8) min ( P 0.05). In both LDP group and ODP group, none occurred percutaneous drainage, re-admissions, second operation or perioperative death. Conclusions: Compared to ODP, LDP is much safer and more steady in perioperative periodand operation. Patients of pancreatic ductal adenocarcinoma received LDP can acquire more benefit and recovery sooner, and LDP is a safe and effective operative method.

  9. Color balancing in CCD color cameras using analog signal processors made by Kodak

    Science.gov (United States)

    Kannegundla, Ram

    1995-03-01

    The green, red, and blue color filters used for CCD sensors generally have different responses. It is often necessary to balance these three colors for displaying a high-quality image on the monitor. The color filter arrays on sensors have different architectures. A CCD with standard G R G B pattern is considered for the present discussion. A simple method of separating the colors using CDS/H that is a part of KASPs (Analog Signal Processors made by Kodak) and using the gain control, which is also a part of KASPs for color balance, is presented. The colors are separated from the video output of sensor by using three KASPs, one each for green, red, and blue colors and by using alternate sample pulses for green and 1 in 4 pulses for red and blue. The separated colors gain is adjusted either automatically or manually and sent to the monitor for direct display in the analog mode or through an A/D converter digitally to the memory. This method of color balancing demands high-quality ASPs. Kodak has designed four different chips with varying levels of power consumption and speed for analog signal processing of video output of CCD sensors. The analog ASICs have been characterized for noise, clock feedthrough, acquisition time, linearity, variable gain, line rate clamp, black muxing, affect of temperature variations on chip performance, and droop. The ASP chips have met their design specifications.

  10. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph

    2017-07-11

    A photovoltaic panel mounting clip comprising a base, central indexing tabs, flanges, lateral indexing tabs, and vertical indexing tabs. The mounting clip removably attaches one or more panels to a beam or the like structure, both mechanically and electrically. It provides secure locking of the panels in all directions, while providing guidance in all directions for accurate installation of the panels to the beam or the like structure.

  11. 49 CFR 179.10 - Tank mounting.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Tank mounting. 179.10 Section 179.10 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Design Requirements § 179.10 Tank mounting. (a) The manner in which tanks are attached to the car...

  12. Versatile ultrafast pump-probe imaging with high sensitivity CCD camera

    OpenAIRE

    Pezeril , Thomas; Klieber , Christoph; Temnov , Vasily; Huntzinger , Jean-Roch; Anane , Abdelmadjid

    2012-01-01

    International audience; A powerful imaging technique based on femtosecond time-resolved measurements with a high dynamic range, commercial CCD camera is presented. Ultrafast phenomena induced by a femtosecond laser pump are visualized through the lock-in type acquisition of images recorded by a femtosecond laser probe. This technique allows time-resolved measurements of laser excited phenomena at multiple probe wavelengths (spectrometer mode) or conventional imaging of the sample surface (ima...

  13. Systems approach to the design of the CCD sensors and camera electronics for the AIA and HMI instruments on solar dynamics observatory

    Science.gov (United States)

    Waltham, N.; Beardsley, S.; Clapp, M.; Lang, J.; Jerram, P.; Pool, P.; Auker, G.; Morris, D.; Duncan, D.

    2017-11-01

    Solar Dynamics Observatory (SDO) is imaging the Sun in many wavelengths near simultaneously and with a resolution ten times higher than the average high-definition television. In this paper we describe our innovative systems approach to the design of the CCD cameras for two of SDO's remote sensing instruments, the Atmospheric Imaging Assembly (AIA) and the Helioseismic and Magnetic Imager (HMI). Both instruments share use of a custom-designed 16 million pixel science-grade CCD and common camera readout electronics. A prime requirement was for the CCD to operate with significantly lower drive voltages than before, motivated by our wish to simplify the design of the camera readout electronics. Here, the challenge lies in the design of circuitry to drive the CCD's highly capacitive electrodes and to digitize its analogue video output signal with low noise and to high precision. The challenge is greatly exacerbated when forced to work with only fully space-qualified, radiation-tolerant components. We describe our systems approach to the design of the AIA and HMI CCD and camera electronics, and the engineering solutions that enabled us to comply with both mission and instrument science requirements.

  14. Laparoscopic distal pancreatectomy for adenocarcinoma: safe and reasonable?

    Science.gov (United States)

    Postlewait, Lauren M.

    2015-01-01

    As a result of technological advances during the past two decades, surgeons now use minimally invasive surgery (MIS) approaches to pancreatic resection more frequently, yet the role of these approaches for pancreatic ductal adenocarcinoma resections remains uncertain, given the aggressive nature of this malignancy. Although there are no controlled trials comparing MIS technique to open surgical technique, laparoscopic distal pancreatectomy for pancreatic adenocarcinoma is performed with increasing frequency. Data from retrospective studies suggest that perioperative complication profiles between open and laparoscopic distal pancreatectomy are similar, with perhaps lower blood loss and fewer wound infections in the MIS group. Concerning oncologic outcomes, there appear to be no differences in the rate of achieving negative margins or in the number of lymph nodes (LNs) resected when compared to open surgery. There are limited recurrence and survival data on laparoscopic compared to open distal pancreatectomy for pancreatic adenocarcinoma, but in the few studies that assess long term outcomes, recurrence rates and survival outcomes appear similar. Recent studies show that though laparoscopic distal pancreatectomy entails a greater operative cost, the associated shorter length of hospital stay leads to decreased overall cost compared to open procedures. Multiple new technologies are emerging to improve resection of pancreatic cancer. Robotic pancreatectomy is feasible, but there are limited data on robotic resection of pancreatic adenocarcinoma, and outcomes appear similar to laparoscopic approaches. Additionally fluorescence-guided surgery represents a new technology on the horizon that could improve oncologic outcomes after resection of pancreatic adenocarcinoma, though published data thus far are limited to animal models. Overall, MIS distal pancreatectomy appears to be a safe and reasonable approach to treating selected patients with pancreatic ductal

  15. Ocean floor mounting of wave energy converters

    Science.gov (United States)

    Siegel, Stefan G

    2015-01-20

    A system for mounting a set of wave energy converters in the ocean includes a pole attached to a floor of an ocean and a slider mounted on the pole in a manner that permits the slider to move vertically along the pole and rotate about the pole. The wave energy converters can then be mounted on the slider to allow adjustment of the depth and orientation of the wave energy converters.

  16. Distal finger replantation.

    Science.gov (United States)

    Scheker, Luis R; Becker, Giles W

    2011-03-01

    Reconstruction of the fingertip distal to the flexor tendon insertion by replantation remains controversial and technically challenging, but the anatomy of the fingertip has been well described and provides help in surgical planning. The open-book surgical technique is described with potential complications and is illustrated with clinical cases. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. Distal renal tubular acidosis and hepatic lipidosis in a cat.

    Science.gov (United States)

    Brown, S A; Spyridakis, L K; Crowell, W A

    1986-11-15

    Clinical and laboratory evidence of hepatic failure was found in a chronically anorectic cat. Simultaneous blood and urine pH determinations established a diagnosis of distal renal tubular acidosis. The cat did not respond to treatment. Necropsy revealed distal tubular nephrosis and hepatic lipidosis. The finding of distal renal tubular acidosis in a cat with hepatic lipidosis emphasizes the importance of complete evaluation of acid-base disorders in patients.

  18. Flat Field Anomalies in an X-ray CCD Camera Measured Using a Manson X-ray Source (HTPD 08 paper)

    International Nuclear Information System (INIS)

    Haugh, M; Schneider, M B

    2008-01-01

    The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. The intensity distribution taken by the SXI camera during a NIF shot is used to determine how accurately NIF can aim laser beams. This is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 (micro)m square pixels, and 15 (micro)m thick. A multi-anode Manson X-ray source, operating up to 10kV and 10W, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/ΔE ∼ 10. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within ±1% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation occurred at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was not observable below 4 keV. We were also able to observe debris, damage, and surface defects on the CCD chip. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager

  19. Multicenter comparative study of laparoscopic and open distal pancreatectomy using propensity score-matching.

    Science.gov (United States)

    Nakamura, Masafumi; Wakabayashi, Go; Miyasaka, Yoshihiro; Tanaka, Masao; Morikawa, Takanori; Unno, Michiaki; Tajima, Hiroshi; Kumamoto, Yusuke; Satoi, Sohei; Kwon, Masanori; Toyama, Hirochika; Ku, Yonson; Yoshitomi, Hideyuki; Nara, Satoshi; Shimada, Kazuaki; Yokoyama, Takahide; Miyagawa, Shinichi; Toyama, Yoichi; Yanaga, Katsuhiko; Fujii, Tsutomu; Kodera, Yasuhiro; Tomiyama, Yasuyuki; Miyata, Hiroaki; Takahara, Takeshi; Beppu, Toru; Yamaue, Hiroki; Miyazaki, Masaru; Takada, Tadahiro

    2015-10-01

    Laparoscopic distal pancreatectomy has been shown to be associated with favorable postoperative outcomes using meta-analysis. However, there have been no randomized controlled studies yet. This study aimed to compare laparoscopic and open distal pancreatectomy using propensity score-matching. We retrospectively collected perioperative data of 2,266 patients who underwent distal pancreatectomy in 69 institutes from 2006-2013 in Japan. Among them, 2,010 patients were enrolled in this study and divided into two groups, laparoscopic distal pancreatectomy and open distal pancreatectomy. Perioperative outcomes were compared between the groups using unmatched and propensity matched analysis. After propensity score-matching, laparoscopic distal pancreatectomy was associated with favorable perioperative outcomes compared with open distal pancreatectomy, including higher rate of preservation of spleen and splenic vessels (P pancreatectomy was associated with more favorable perioperative outcomes than open distal pancreatectomy. © 2015 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  20. X-ray CCD image sensor with a thick depletion region

    International Nuclear Information System (INIS)

    Saito, Hirobumi; Watabe, Hiroshi.

    1984-01-01

    To develop a solid-state image sensor for high energy X-ray above 1 -- 2 keV, basic studies have been made on the CCD (charge coupled device) with a thick depletion region. A method of super-imposing a high DC bias voltage on low voltage signal pulses was newly proposed. The characteristics of both SCCD and BCCD were investigated, and their ability as X-ray sensors was compared. It was found that a depletion region of 60 μm thick was able to be obtained with ordinary doping density of 10 20 /m 3 , and that even thicker over 1 mm depletion region was able to be obtained with doping density of about 10 18 /m 3 , and a high bias voltage above 1 kV was able to be applied. It is suggested that the CCD image sensors for 8 keV or 24 keV X-ray can be realized since the absorption length of these X-ray in Si is about 60 μm and 1 mm, respectively. As for the characteristics other than the depletion thickness, the BCCD is preferable to SCCD for the present purpose because of lower noise and dark current. As for the transfer method, the frame-transfer method is recommended. (Aoki, K.)

  1. High-performance dual-speed CCD camera system for scientific imaging

    Science.gov (United States)

    Simpson, Raymond W.

    1996-03-01

    Traditionally, scientific camera systems were partitioned with a `camera head' containing the CCD and its support circuitry and a camera controller, which provided analog to digital conversion, timing, control, computer interfacing, and power. A new, unitized high performance scientific CCD camera with dual speed readout at 1 X 106 or 5 X 106 pixels per second, 12 bit digital gray scale, high performance thermoelectric cooling, and built in composite video output is described. This camera provides all digital, analog, and cooling functions in a single compact unit. The new system incorporates the A/C converter, timing, control and computer interfacing in the camera, with the power supply remaining a separate remote unit. A 100 Mbyte/second serial link transfers data over copper or fiber media to a variety of host computers, including Sun, SGI, SCSI, PCI, EISA, and Apple Macintosh. Having all the digital and analog functions in the camera made it possible to modify this system for the Woods Hole Oceanographic Institution for use on a remote controlled submersible vehicle. The oceanographic version achieves 16 bit dynamic range at 1.5 X 105 pixels/second, can be operated at depths of 3 kilometers, and transfers data to the surface via a real time fiber optic link.

  2. A luminescence imaging system based on a CCD camera

    DEFF Research Database (Denmark)

    Duller, G.A.T.; Bøtter-Jensen, L.; Markey, B.G.

    1997-01-01

    Stimulated luminescence arising from naturally occurring minerals is likely to be spatially heterogeneous. Standard luminescence detection systems are unable to resolve this variability. Several research groups have attempted to use imaging photon detectors, or image intensifiers linked...... to photographic systems, in order to obtain spatially resolved data. However, the former option is extremely expensive and it is difficult to obtain quantitative data from the latter. This paper describes the use of a CCD camera for imaging both thermoluminescence and optically stimulated luminescence. The system...

  3. Novel driver method to improve ordinary CCD frame rate for high-speed imaging diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Tong-Ding, E-mail: snuohui@126.com; Li, Bin-Kang; Yang, Shao-Hua; Guo, Ming-An; Yan, Ming

    2016-06-21

    The use of ordinary Charge-coupled-Device (CCD) imagers for the analysis of fast physical phenomenon is restricted because of the low-speed performance resulting from their long output times. Even though the form of Intensified-CCD (ICCD), coupled with a gated image intensifier, has extended their use for high speed imaging, the deficiency remains to be solved that ICDD could record only one image in a single shot. This paper presents a novel driver method designed to significantly improve the ordinary interline CCD burst frame rate for high-speed photography. This method is based on the use of vertical registers as storage, so that a small number of additional frames comprised of reduced-spatial-resolution images obtained via a specific sampling operation can be buffered. Hence, the interval time of the received series of images is related to the exposure and vertical transfer times only and, thus, the burst frame rate can be increased significantly. A prototype camera based on this method is designed as part of this study, exhibiting a burst rate of up to 250,000 frames per second (fps) and a capacity to record three continuous images. This device exhibits a speed enhancement of approximately 16,000 times compared with the conventional speed, with a spatial resolution reduction of only 1/4.

  4. Fractures of the bilateral distal radius and scaphoid: a case report

    Directory of Open Access Journals (Sweden)

    Ozkan Korhan

    2008-03-01

    Full Text Available Abstract Introduction Bilateral fractures of the distal radius and scaphoid are extremely rare injuries. Case presentation A patient with bilateral comminuted, displaced distal fractures of the radius and bilateral fractures of the scaphoid was treated via internal fixation of the scaphoid fractures with Herbert screws and internal fixation of the distal radius fractures with locked volar plating. Conclusion Rigid internal fixation of distal radius and scaphoid fractures is mandatory to start early active rehabilitation of the wrist without the need for wrist immobilization with a plaster or external skeletal fixation.

  5. Fallow land mapping for better crop monitoring in Huang-Huai-Hai Plain using HJ-1 CCD data

    International Nuclear Information System (INIS)

    Zhang, Miao; Wu, Bingfang; Meng, Jihua; Dong, Taifeng; You, Xingzhi

    2014-01-01

    The prediction of grain production is essential for socio-economic development planning, guidance and control of macro cropping structure adjustment. Fallow areas should be identified each growing season which is critical for grain production prediction. This paper focuses on fallow arable land monitoring during summer grain season in the Huang-Huai-Hai Plain using China Environment Satellite HJ-1 CCD data. With the two satellites HJ-1A and HJ-1B, high temporal Normalized Difference Vegetation Index (NDVI) can be obtained. HJ-1 CCD data were acquired from early March to early June in 2010 over the Huang-Huai-Hai Plain. Multi-temporal HJ-1 CCD data were pre-processed and time series of NDVI were derived. An algorithm for separating cropped and fallow areas was developed based on three key periods of NDVI in early-March, mid-April and mid-May, 2010. The influence of fallow arable lands to yield estimation and crop condition monitoring over the Huang-Huai-Hai Plain were also investigated and analyzed. Preliminary results in this paper showed that HJ-1 CCD data are capable for fallow land monitoring. Information of fallow arable lands is an essential part of crop monitoring and it should be incorporated into crop monitoring systems. In the future, the fallow lands over autumn grain season should also be identified and information of fallow arable lands should be generated yearly in order to get more reliable production prediction

  6. "Split Cast Mounting: Review and New Technique".

    Science.gov (United States)

    Gundawar, S M; Pande, Neelam A; Jaiswal, Priti; Radke, U M

    2014-12-01

    For the fabrication of a prosthesis, the Prosthodontist meticulously performs all the steps. The laboratory technician then make every effort/strives to perform the remaining lab procedures. However when the processed dentures are remounted on the articulator, some changes are seen. These changes may be divided into two categories: Pre-insertion and post-insertion changes, which deal with the physical properties of the materials involved (Parker, J Prosthet Dent 31:335-342, 1974). Split cast mounting is the method of mounting casts on the articulator. It is essentially a maxillary cast constructed in two parts with a horizontal division. The procedure allows for the verification of the accuracy of the initial mounting and the ease of removal and replacement of the cast. This provides a precise means of correcting the changes in occlusion occurring as a result of the processing technique (Nogueira et al., J Prosthet Dent 91:386-388, 2004). Instability of the split mounting has always been a problem to the Prosthodontist thereby limiting its use. There are various materials mentioned in the literature. The new technique by using Dowel pins and twill thread is very easy, cheaper and simple way to stabilize the split mounting. It is useful and easy in day to day laboratory procedures. The article presents different methods of split cast mounting and the new procedure using easily available materials in prosthetic laboratory.

  7. Distally based superficial sural artery flap for soft tissue coverage in the distal 2/3 of leg and foot

    Directory of Open Access Journals (Sweden)

    Kamath B

    2005-01-01

    Full Text Available Background: Skin coverage for defects in the lower 2/3 of leg, ankle region and posterior heel has always been a difficult challenge for reconstructive surgeon. Methods: We describe our experience with the distally based superficial sural artery flap coverage in 48 patients with moderate sized defects in these difficult areas. Results: One out of 48 flaps (in 48 patients was lost totally and 3 suffered marginal necrosis which did not require any secondary procedure. These complications could have been avoided by proper selection of cases and refining technical skills. Conclusion: This simple procedure could be an important and versatile tool for any reconstructive surgeon in providing skin coverage in the distal leg and proximal foot. Preservation of major arteries of the lower limb, minimal donor defect, relatively uninjured donor area in compound fracture or poly trauma involving distal leg are some of the advantages of the flap.

  8. First tests with fully depleted PN-CCD's

    International Nuclear Information System (INIS)

    Strueder, L.; Lutz, G.; Sterzik, M.; Holl, P.; Kemmer, J.; Prechtel, U.; Ziemann, T.; Rehak, P.

    1987-01-01

    We have fabricated 280 μm thick fully depletable pn CCD's on high resistivity silicon (/rho/ ∼ 2.5 kΩcm). Its operation is based on the semiconductor drift chamber principle proposed by Gatti and Rheak. They are designed as energy and position sensitive radiation detector for (minimum) ionizing particles and X-ray imaging. Two dimensional semiconductor device modeling demonstrates the basic charge transer mechanisms. Prototypes of the detectors have been tested in static and dynamic conditions. A preliminary charge transfer inefficiency was determined to 6 x 10/sup/minus/3/. The charge loss during the transfer is discussed and as a consequence we have developed an improved design for a second fabrication iteration which is now being produced. 4 refs., 15 figs

  9. Research on LQR optimal control method of active engine mount

    Science.gov (United States)

    Huan, Xie; Yu, Duan

    2018-04-01

    In this paper, the LQR control method is applied to the active mount of the engine, and a six-cylinder engine excitation model is established. Through the joint simulation of AMESim and MATLAB, the vibration isolation performance of the active mount system and the passive mount system is analyzed. Excited by the multi-engine operation, the simulation results of the vertical displacement, acceleration and dynamic deflection of the vehicle body show that the vibration isolation capability of the active mount system is superior to that of the passive mount system. It shows that compared with the passive mount, LQR active mount can greatly improve the vibration isolation performance, which proves the feasibility and effectiveness of the LQR control method.

  10. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph; Valdes, Francisco

    2017-02-14

    An exemplary mounting clip for removably attaching panels to a supporting structure comprises a base, spring locking clips, a lateral flange, a lever flange, and a spring bonding pad. The spring locking clips extend upwardly from the base. The lateral flange extends upwardly from a first side of the base. The lateral flange comprises a slot having an opening configured to receive at least a portion of one of the one or more panels. The lever flange extends outwardly from the lateral flange. The spring bonding flange extends downwardly from the lever flange. At least a portion of the first spring bonding flange comprises a serrated edge for gouging at least a portion of the one or more panels when the one or more panels are attached to the mounting clip to electrically and mechanically couple the one or more panels to the mounting clip.

  11. Photoelectric panel with equatorial mounting of drive

    Science.gov (United States)

    Kukhta, M. S.; Krauinsh, P. Y.; Krauinsh, D. P.; Sokolov, A. P.; Mainy, S. B.

    2018-03-01

    The relevance of the work is determined by the need to create effective models for sunny energy. The article considers a photoelectric panel equipped with a system for tracking the sun. Efficiency of the system is provided by equatorial mounting, which compensates for the rotation of the Earth by rotating the sunny panel in the plane of the celestial equator. The specificity of climatic and geographical conditions of Tomsk is estimated. The dynamics of power variations of photoelectric panels with equatorial mounting during seasonal fluctuations in Tomsk is calculated. A mobile photovoltaic panel with equatorial mounting of the drive has been developed. The methods of design strategy for placing photovoltaic panels in the architectural environment of the city are presented. Key words: sunny energy, photovoltaics, equatorial mounting, mechatronic model, wave reducer, electric drive.

  12. The impact of splenectomy on outcomes after distal and total pancreatectomy

    Directory of Open Access Journals (Sweden)

    Bramhall Simon

    2007-06-01

    Full Text Available Abstract Background Several authors advocate spleen preserving distal pancreatectomy, because of the increased complication rate after splenectomy. Methods Postoperative complications and survival after distal and total pancreatectomy, were recorded and retrospectively analyzed according to spleen preservation. Patients, who underwent distal and total pancreatectomy without histologically proven adenocarcinoma, or extrapancreatic disease, were included in the cohort which was divided into splenectomy and no splenectomy groups. Statistical analysis was performed using Fisher's test. Results The study group consisted of 62 patients who underwent distal and total pancreatectomy between 26/11/1987 to 6/1/2006. Splenectomy was performed in 35 out of 62 patients (56.5%, distal pancreatectomy was performed in 49 out of 62 patients (79%. Morbidity rate was 28.6% in splenectomy group and 14.8% in the no splenectomy group (p = 0.235, while 30 days mortality rate was 2.9%; one patient died in the splenectomy group (p = 1. Conclusion Spleen-preservation did not influence the outcomes after distal and total pancreatectomy in our series.

  13. Brayton Isotope Power System. Phase I. (Ground demonstration system) Configuration Control Document (CCD)

    International Nuclear Information System (INIS)

    1976-01-01

    The configuration control document (CCD) defines the BIPS-GDS configuration. The GDS configuration is similar to a conceptual flight system design, referred to as the BIPS-FS, which is discussed in App. I. The BIPS is being developed by ERDA as a 500 to 2000 W(e), 7-y life, space power system utilizing a closed Brayton cycle gas turbine engine to convert thermal energy (from an isotope heat source) to electrical energy at a net efficiency exceeding 25 percent. The CCD relates to Phase I of an ERDA Program to qualify a dynamic system for launch in the early 1980's. Phase I is a 35-month effort to provide an FS conceptual design and GDS design, fabrication, and test. The baseline is a 7-year life, 450-pound, 4800 W(t), 1300 W(e) system which will use two multihundred watt (MHW) isotope heat sources being developed

  14. Two-wave propagation in in vitro swine distal ulna

    Science.gov (United States)

    Mano, Isao; Horii, Kaoru; Matsukawa, Mami; Otani, Takahiko

    2015-07-01

    Ultrasonic transmitted waves were obtained in an in vitro swine distal ulna specimen, which mimics a human distal radius, that consists of interconnected cortical bone and cancellous bone. The transmitted waveforms appeared similar to the fast waves, slow waves, and overlapping fast and slow waves measured in the specimen after removing the surface cortical bone (only cancellous bone). In addition, the circumferential waves in the cortical bone and water did not affect the fast and slow waves. This suggests that the fast-and-slow-wave phenomenon can be observed in an in vivo human distal radius.

  15. Near-infrared Raman spectroscopy using a diode laser and CCD detector for tissue diagnostics

    International Nuclear Information System (INIS)

    Gustafsson, U.

    1993-09-01

    This paper surveys the possibility to observe high-quality NIR Raman spectra of both fluorescent and non-fluorescent samples with the use of a diode laser, a fibre optic sample, a single spectrometer and a charge-coupled device (CCD) detector. A shifted excitation difference technique was implemented for removing the broad-band fluorescence emission from Raman spectra of the highly fluorescent samples. Raman spectra of 1.4-dioxane, toluene, rhodamine 6G, and HITCI in the 640 to 1840 cm -1 spectral region and 1.4-dioxane and toluene in the 400 to 3400 cm -1 spectral region have been recorded. The results open the field of sensitive tissue characterisation and the possibility of optical biopsy in vivo by using NIR Raman spectroscopy with fibre optic sampling, a single spectrometer, and a CCD detector

  16. New Cepheid distances to nearby galaxies based on BVRI CCD photometry. III - NGC 300

    Energy Technology Data Exchange (ETDEWEB)

    Freedman, W.L.; Madore, B.F.; Hawley, S.L.; Horowitz, I.K.; Mould, J.; Navarrete, M.; Sallmen, S. (Carnegie Institution of Washington, Observatories, Pasadena, CA (United States) JPL, Pasadena, CA (United States) Lawrence Livermore National Laboratory, Livermore, CA (United States) California Institute of Technology, Pasadena (United States) Cerro Tololo Inter-American Observatory, La Serena (Chile) California, University, Berkeley (United States))

    1992-09-01

    A true distance modulus of (m - M) sub 0 = 26.66 +/- 0.10 mag (corresponding to 2.1 +/- 0.1 Mpc) has been determined for the Sculptor Group spiral galaxy NGC 300. New CCD data have been obtained for a sample of known Cepheids in this galaxy from which apparent distance moduli at B, V, R, and I wavelengths are determined. Combining the data available at different wavelenghts, and assuming a true distance modulus to the LMC of 18.5 mag, a true distance modulus is obtained for NGC 300, corrected for the effects of interstellar reddening. The availability of a new distance to NGC 300 brings to five the total number of galaxies with new CCD photometry of Cepheids, useful for calibration of the Hubble constant. 26 refs.

  17. Measurements of 161 Double Stars With a High-Speed CCD: The Winter/Spring 2017 Observing Program at Brilliant Sky Observatory, Part 2

    Science.gov (United States)

    Harshaw, Richard

    2018-04-01

    In the winter and spring of 2017, an aggressive observing program of measuring close double stars with speckle interferometry and CCD imaging was undertaken at Brilliant Sky Observatory, my observing site in Cave Creek, Arizona. A total of 596 stars were observed, 8 of which were rejected for various reasons, leaving 588 pairs. Of these, 427 were observed and measured with speckle interferometry, while the remaining 161 were measured with a CCD. This paper reports the results of the observations of the 161 CCD cases. A separate paper in this issue will report the speckle measurements of the 427 other pairs.

  18. MRI of fractures of the distal radius: comparison with conventional radiographs

    International Nuclear Information System (INIS)

    Spence, L.D.; Eustace, S.

    1998-01-01

    Objective. To compare the evaluation of fractures of the distal radius with MRI and conventional radiographs. To demonstrate the ability of MRI to detect unsuspected soft tissue derangement accompanying this common injury. Design and patients. Twenty-one consecutive inpatients admitted following fracture of the distal radius underwent preoperative evaluation with both conventional radiographs and MRI. In each case, analysis was made of both the osseous and soft tissue injury. MRI findings were compared with those identified on conventional radiographs and at subsequent surgical fixation. Results. Of 21 patients with fractures of the distal radius, 20 had extension to the radiocarpal articulation, 14 had distal radio-ulnar joint extension and 5 had avulsion of the ulnar styloid.Occult carpal bone fractures accompanying fracture of the distal radius were identified in two patients: one of the capitate and the other of the second metacarpal base. Ten patients (48%) had associated soft tissue injury: six patients had scapholunate ligament rupture, two patients had disruption of the triangular fibrocartilage, one patient had extensor carpi ulnaris tenosynovitis and one patient had a tear of a dorsal radiocarpal ligament. Of five patients with ulnar styloid avulsions, none had evidence of triangular fibrocartilage tears. Conclusion. MRI affords better evaluation of osseous injury accompanying distal radial fractures than conventional radiographs. Intra-articular soft tissue injury accompanies distal radial fractures in almost 50% of cases. Scapholunate ligament disruption commonly accompanies intra-articular fracture through the lunate facet of the distal radius. Fracture of the ulnar styloid is infrequently associated with tear of the triangular fibrocartilage. (orig.)

  19. MRI of fractures of the distal radius: comparison with conventional radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Spence, L.D.; Eustace, S. [Medical Center, Boston, MA (United States). Dept. of Radiol.; Savenor, A.; Nwachuku, I.; Tilsley, J. [Department of Orthopedics, Boston Medical Center, Boston, MA 02118 (United States)

    1998-05-01

    Objective. To compare the evaluation of fractures of the distal radius with MRI and conventional radiographs. To demonstrate the ability of MRI to detect unsuspected soft tissue derangement accompanying this common injury. Design and patients. Twenty-one consecutive inpatients admitted following fracture of the distal radius underwent preoperative evaluation with both conventional radiographs and MRI. In each case, analysis was made of both the osseous and soft tissue injury. MRI findings were compared with those identified on conventional radiographs and at subsequent surgical fixation. Results. Of 21 patients with fractures of the distal radius, 20 had extension to the radiocarpal articulation, 14 had distal radio-ulnar joint extension and 5 had avulsion of the ulnar styloid.Occult carpal bone fractures accompanying fracture of the distal radius were identified in two patients: one of the capitate and the other of the second metacarpal base. Ten patients (48%) had associated soft tissue injury: six patients had scapholunate ligament rupture, two patients had disruption of the triangular fibrocartilage, one patient had extensor carpi ulnaris tenosynovitis and one patient had a tear of a dorsal radiocarpal ligament. Of five patients with ulnar styloid avulsions, none had evidence of triangular fibrocartilage tears. Conclusion. MRI affords better evaluation of osseous injury accompanying distal radial fractures than conventional radiographs. Intra-articular soft tissue injury accompanies distal radial fractures in almost 50% of cases. Scapholunate ligament disruption commonly accompanies intra-articular fracture through the lunate facet of the distal radius. Fracture of the ulnar styloid is infrequently associated with tear of the triangular fibrocartilage. (orig.) With 5 figs., 16 refs.

  20. BVI CCD photometry of 47 Tucanae

    International Nuclear Information System (INIS)

    Alcaino, G.; Liller, W.

    1987-01-01

    CCD BVI main-sequence photometry of 47 Tuc is presented, matched to the recent BVI isochrones of VandenBerg and Bell (1985). The main-sequence turnoffs are found to be at V = 17.60 + or - 0.1, B-V = 0.56 + or - 0.02; V-I = 0.68 + or - 0.02, and B-I = 1.24 + or - 0.02. The magnitude difference between the main-sequence turnoff and the horizontal branch is 3.55 + or - 0.15 for all three color indices. A consistent age for 47 Tuc of 17 Gyr and a consistent distance modulus of (m-M)v = 13.2 are obtained for all three indices, and an absolute magnitude of Mv = 0.85 is determined for the horizontal branch stars. The results also favor the adoption of (Fe/H) near -0.5 as the best abundance value for 47 Tuc. 38 references

  1. Young Children's Sibling Relationship Quality: Distal and Proximal Correlates

    Science.gov (United States)

    Kretschmer, Tina; Pike, Alison

    2009-01-01

    Background: Relationships within families are interdependent and related to distal environmental factors. Low socioeconomic status (SES) and high household chaos (distal factors) have been linked to less positive marital and parent-child relationships, but have not yet been examined with regard to young children's sibling relationships. The…

  2. Clinical relevance of distal biceps insertional and footprint anatomy

    NARCIS (Netherlands)

    van den Bekerom, Michel P J; Kodde, Izaäk F.; Aster, Asir; Bleys, Ronald L A W; Eygendaal, Denise

    2016-01-01

    Purpose: The aim of this review was to present an overview, based on a literature search, of surgical anatomy for distal biceps tendon repairs, based on the current literature. Methods: A narrative review was performed using Pubmed/Medline using key words: Search terms were distal biceps,

  3. Neutral-beam performance analysis using a CCD camera

    International Nuclear Information System (INIS)

    Hill, D.N.; Allen, S.L.; Pincosy, P.A.

    1986-01-01

    We have developed an optical diagnostic system suitable for characterizing the performance of energetic neutral beams. An absolutely calibrated CCD video camera is used to view the neutral beam as it passes through a relatively high pressure (10 -5 Torr) region outside the neutralizer: collisional excitation of the fast deuterium atoms produces H/sub proportional to/ emission (lambda = 6561A) that is proportional to the local atomic current density, independent of the species mix of accelerated ions over the energy range 5 to 20 keV. Digital processing of the video signal provides profile and aiming information for beam optimization. 6 refs., 3 figs

  4. Concave distal end of ulna metaphysis alone is not a sign of rickets

    Energy Technology Data Exchange (ETDEWEB)

    Oestreich, Alan E. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, 5031, Cincinnati, OH (United States)

    2015-07-15

    Statements have been made in the literature and in legal testimony that misrepresent the radiographic finding of concave distal end of the ulnar metaphysis. To demonstrate that a concave distal end of the ossified ulna in infancy can be normal. Eighty distal wrists of randomly selected infants in the first year of life with radiographic evidence that ruled out rickets were reviewed. In 16 of the cases (20%), mild or moderate concavity of the distal end of the ulna was seen. An intact metaphyseal collar of distal radius or ulna confirmed the absence of radiographic rickets. The finding of 20% of concave distal ulnas in the first year of life confirms the widely acknowledged statements that concave distal end of the ulna alone is not indicative of rickets. Statements to the contrary are not justified. (orig.)

  5. Concave distal end of ulna metaphysis alone is not a sign of rickets

    International Nuclear Information System (INIS)

    Oestreich, Alan E.

    2015-01-01

    Statements have been made in the literature and in legal testimony that misrepresent the radiographic finding of concave distal end of the ulnar metaphysis. To demonstrate that a concave distal end of the ossified ulna in infancy can be normal. Eighty distal wrists of randomly selected infants in the first year of life with radiographic evidence that ruled out rickets were reviewed. In 16 of the cases (20%), mild or moderate concavity of the distal end of the ulna was seen. An intact metaphyseal collar of distal radius or ulna confirmed the absence of radiographic rickets. The finding of 20% of concave distal ulnas in the first year of life confirms the widely acknowledged statements that concave distal end of the ulna alone is not indicative of rickets. Statements to the contrary are not justified. (orig.)

  6. A novel model of distal colon cancer in athymic mice Novo modelo de câncer de cólon distal em camundongos atímicos

    Directory of Open Access Journals (Sweden)

    Denise Gonçalves Priolli

    2012-06-01

    Full Text Available PURPOSE: The present a novel adenocarcinoma model in athymic mice. METHODS: Seven athymic mice were used. Colon diversion and distal fistula were made. Adenocarcinoma cells were inoculated in the submucosa of fistula. Tumor growth was monitored daily. Scintigraphy with 99mTc-MIBI was performed to identify the tumor. RESULTS: The model of distal colon cancer is feasible. Tumor detection was possible by both, macroscopically and molecular imaging. All resections demonstrated poorly differentiated tumors. Colon obstruction occurred in one case, similarly to evolution in human tumors of distal colon. CONCLUSION: The proposed model of distal colon cancer is feasible, allows for easy monitoring of tumoral growth by both, macroscopically and molecular imaging, and is suitable for studying the evolution of tumor with implementation of cytotoxic therapy in vivo.OBJETIVO: Apresentar novo modelo de adenocarcinoma distal em camundongos atímicos. MÉTODOS: Foram utilizados sete camundongos atímicos. Desvio do cólon distal e fístula foram feitas. Células de adenocarcinoma foram inoculadas na submucosa da fístula. O crescimento do tumor foi monitorado diariamente. Cintilografia com 99mTc-MIBI foi realizada para identificar o tumor. RESULTADOS: O modelo de câncer de cólon distal é viável. Detecção do tumor foi possível macroscopicamente e por imagem molecular. Todas as ressecções demonstraram tumores pouco diferenciados. Obstrução do cólon ocorreu em um caso, de forma semelhante à evolução em tumores humanos do cólon distal. CONCLUSÃO: O modelo de câncer do cólon distal proposto é viável, permite a monitorização fácil do crescimento tumoral macroscopicamente e por imagem molecular, sendo adequado para o estudo da evolução de tumor com aplicação de terapia citotóxica in vivo.

  7. [The controversy of routine articulator mounting in orthodontics].

    Science.gov (United States)

    Wang, Li; Han, Xianglong; Bai, Ding

    2013-06-01

    Articulators have been widely used by clinicians of dentistry. But routine articulator mounting is still controversial in orthodontics. Orthodontists oriented by gnathology approve routine articulator mounting while nongnathologic orthodontists disapprove it. This article reviews the thoughts of orthodontist that they agree or disagree with routine articulator mounting based on the considerations of biting, temporomandibular disorder (TMD), periodontitis, and so on.

  8. Opinion rating of comparison photographs of television pictures from CCD cameras under irradiation

    International Nuclear Information System (INIS)

    Reading, V.M.; Dumbreck, A.A.

    1991-01-01

    As part of the development of a general method of testing the effects of gamma radiation on CCD television cameras, this is a report of an experimental study on the optimisation of still photographic representation of video pictures recorded before and during camera irradiation. (author)

  9. Effects of exogenous glucagon-like peptide-2 and distal bowel resection on intestinal and systemic adaptive responses in rats

    DEFF Research Database (Denmark)

    Lai, Sarah W; de Heuvel, Elaine; Wallace, Laurie E

    2017-01-01

    mount immunohistochemistry for neurons (HuC/D, VIP, nNOS), plasma glucose, gut hormones, and body composition. RESULTS: Resection increased the proportion of nNOS immunopositive myenteric neurons, intestinal muscularis propria thickness and crypt cell proliferation, which were not recapitulated by GLP-2......-2 attenuated resection-induced increases in blood glucose and body fat loss. CONCLUSIONS: Exogenous GLP-2 stimulates jejunal adaptation independent of enteric neuronal VIP or nNOS changes, and has divergent effects on plasma amylin and peptide YY concentrations. The novel ability of exogenous GLP-2......OBJECTIVE: To determine the effects of exogenous glucagon-like peptide-2 (GLP-2), with or without massive distal bowel resection, on adaptation of jejunal mucosa, enteric neurons, gut hormones and tissue reserves in rats. BACKGROUND: GLP-2 is a gut hormone known to be trophic for small bowel mucosa...

  10. Fishtail deformity - a delayed complication of distal humeral fractures in children

    Energy Technology Data Exchange (ETDEWEB)

    Narayanan, Srikala [Massachusetts General Hospital, Department of Radiology, Division of Pediatric Imaging, Boston, MA (United States); University of Pittsburgh Medical Center, Department of Radiology, Pittsburgh, PA (United States); Shailam, Randheer; Nimkin, Katherine [Massachusetts General Hospital, Department of Radiology, Division of Pediatric Imaging, Boston, MA (United States); Grottkau, Brian E. [Massachusetts General Hospital, Department of Orthopaedics, Pediatric Orthopaedics, Boston, MA (United States)

    2015-06-15

    Concavity in the central portion of the distal humerus is referred to as fishtail deformity. This entity is a rare complication of distal humeral fractures in children. The purpose of this study is to describe imaging features of post-traumatic fishtail deformity and discuss the pathophysiology. We conducted a retrospective analysis of seven cases of fishtail deformity after distal humeral fractures. Seven children ages 7-14 years (five boys, two girls) presented with elbow pain and history of distal humeral fracture. Four of the seven children had limited range of motion. Five children had prior grade 3 supracondylar fracture treated with closed reduction and percutaneous pinning. One child had a medial condylar fracture and another had a lateral condylar fracture; both had been treated with conservative casting. All children had radiographs, five had CT and three had MRI. All children had a concave central defect in the distal humerus. Other imaging features included joint space narrowing with osteophytes and subchondral cystic changes in four children, synovitis in one, hypertrophy or subluxation of the radial head in three and proximal migration of the ulna in two. Fishtail deformity of the distal humerus is a rare complication of distal humeral fractures in children. This entity is infrequently reported in the radiology literature. Awareness of the classic imaging features can result in earlier diagnosis and appropriate treatment. (orig.)

  11. Fishtail deformity - a delayed complication of distal humeral fractures in children

    International Nuclear Information System (INIS)

    Narayanan, Srikala; Shailam, Randheer; Nimkin, Katherine; Grottkau, Brian E.

    2015-01-01

    Concavity in the central portion of the distal humerus is referred to as fishtail deformity. This entity is a rare complication of distal humeral fractures in children. The purpose of this study is to describe imaging features of post-traumatic fishtail deformity and discuss the pathophysiology. We conducted a retrospective analysis of seven cases of fishtail deformity after distal humeral fractures. Seven children ages 7-14 years (five boys, two girls) presented with elbow pain and history of distal humeral fracture. Four of the seven children had limited range of motion. Five children had prior grade 3 supracondylar fracture treated with closed reduction and percutaneous pinning. One child had a medial condylar fracture and another had a lateral condylar fracture; both had been treated with conservative casting. All children had radiographs, five had CT and three had MRI. All children had a concave central defect in the distal humerus. Other imaging features included joint space narrowing with osteophytes and subchondral cystic changes in four children, synovitis in one, hypertrophy or subluxation of the radial head in three and proximal migration of the ulna in two. Fishtail deformity of the distal humerus is a rare complication of distal humeral fractures in children. This entity is infrequently reported in the radiology literature. Awareness of the classic imaging features can result in earlier diagnosis and appropriate treatment. (orig.)

  12. Development of a Double Glass Mounting Method Using Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) and its Evaluation for Permanent Mounting of Small Nematodes.

    Science.gov (United States)

    Zahabiun, Farzaneh; Sadjjadi, Seyed Mahmoud; Esfandiari, Farideh

    2015-01-01

    Permanent slide preparation of nematodes especially small ones is time consuming, difficult and they become scarious margins. Regarding this problem, a modified double glass mounting method was developed and compared with classic method. A total of 209 nematode samples from human and animal origin were fixed and stained with Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) followed by double glass mounting and classic dehydration method using Canada balsam as their mounting media. The slides were evaluated in different dates and times, more than four years. Different photos were made with different magnification during the evaluation time. The double glass mounting method was stable during this time and comparable with classic method. There were no changes in morphologic structures of nematodes using double glass mounting method with well-defined and clear differentiation between different organs of nematodes in this method. Using this method is cost effective and fast for mounting of small nematodes comparing to classic method.

  13. Case study of atmospheric correction on CCD data of HJ-1 satellite based on 6S model

    International Nuclear Information System (INIS)

    Xue, Xiaoiuan; Meng, Oingyan; Xie, Yong; Sun, Zhangli; Wang, Chang; Zhao, Hang

    2014-01-01

    In this study, atmospheric radiative transfer model 6S was used to simulate the radioactive transfer process in the surface-atmosphere-sensor. An algorithm based on the look-up table (LUT) founded by 6S model was used to correct (HJ-1) CCD image pixel by pixel. Then, the effect of atmospheric correction on CCD data of HJ-1 satellite was analyzed in terms of the spectral curves and evaluated against the measured reflectance acquired during HJ-1B satellite overpass, finally, the normalized difference vegetation index (NDVI) before and after atmospheric correction were compared. The results showed: (1) Atmospheric correction on CCD data of HJ-1 satellite can reduce the ''increase'' effect of the atmosphere. (2) Apparent reflectance are higher than those of surface reflectance corrected by 6S model in band1∼band3, but they are lower in the near-infrared band; the surface reflectance values corrected agree with the measured reflectance values well. (3)The NDVI increases significantly after atmospheric correction, which indicates the atmospheric correction can highlight the vegetation information

  14. Spontaneous distal rupture of the plantar fascia.

    Science.gov (United States)

    Gitto, Salvatore; Draghi, Ferdinando

    2018-07-01

    Spontaneous ruptures of the plantar fascia are uncommon injuries. They typically occur at its calcaneal insertion and usually represent a complication of plantar fasciitis and local treatment with steroid injections. In contrast, distal ruptures commonly result from traumatic injuries. We describe the case of a spontaneous distal rupture of the plantar fascia in a 48-year-old woman with a low level of physical activity and no history of direct injury to the foot, plantar fasciitis, or steroid injections. © 2017 Wiley Periodicals, Inc.

  15. Minimally Invasive Distal Pancreatectomy: Review of the English Literature.

    Science.gov (United States)

    Wang, Kai; Fan, Ying

    2017-02-01

    Recently, the superiority of the minimally invasive approach, which results in a better cosmetic result, faster recovery, and shorter length of hospital stay, is a technique that has been progressively recognized as it has developed. And the minimally invasive approach has been applied to distal pancreatectomy (DP), which is a standard method for the treatment of benign, borderline, and part of malignant lesions of the pancreatic body and tail. This article aims to analyze the types, postoperative recovery, and outcomes of laparoscopic distal pancreatectomy (LDP). A systematic search of the scientific literature was performed using PubMed, EMBASE, online journals, and the Internet for all publications on LDP. Articles were selected if the abstract contained patients who underwent LDP for pancreatic diseases. All selected articles were reviewed and analyzed. If there were no contraindications for LDP, this operation is suitable for benign, borderline, or malignant tumors of the pancreatic body and tail, which should try to be performed with preservation of the spleen. LDP is safe and feasible under some conditions to experienced surgeon. Single-incision laparoscopic distal pancreatectomy (S-LDP) and robotic laparoscopic distal pancreatectomy (R-LDP) perioperative outcomes are similar with conventional multi-incision laparoscopic distal pancreatectomy (C-LDP). And the advantages of S-LDP and R-LDP require further exploration. With the application of enhanced recovery program (ERP), length of hospital stay and costs are reduced. LDP is safe and feasible under some conditions. Compared with open distal pancreatectomy, LDP has a lot of advantages; a trend was observed for LDP to replace traditional open surgery. LDP combined with ERP is expected to become standard in the treatment of pancreatic body and tail lesions.

  16. The X-ray mirror telescope and the pn-CCD detector of CAST

    CERN Document Server

    Kuster, M; Englhauser, J; Franz, J; Friedrich, P; Hartmann, R; Kang, D; Kotthaus, R; Lutz, Gerhard; Moralez, J; Serber, W; Strüder, L

    2004-01-01

    The Cern Axion Solar Telescope - CAST - uses a prototype 9 Tesla LHC superconducting dipole magnet to search for a hypothetical pseudoscalar particle, the axion, which was proposed by theory in the 1980s to solve the strong CP problem and which could be a dark matter candidate. In CAST a strong magnetic field is used to convert the solar axions to detectable photons via inverse Primakoff effect. The resulting X-rays are thermally distributed in the energy range of 1-7 keV and can be observed with conventional X-ray detectors. The most sensitive detector system of CAST is a pn-CCD detector originally developed for XMM-Newton combined with a Wolter I type X-ray mirror system. The combination of a focusing X-ray optics and a state of the art pn-CCD detector which combines high quantum efficiency, good spacial and energy resolution, and low background improves the sensitivity of the CAST experiment such that for the first time the axion photon coupling constant can be probed beyond the best astrophysical constrai...

  17. Impact of a Nationwide Training Program in Minimally Invasive Distal Pancreatectomy (LAELAPS)

    NARCIS (Netherlands)

    de Rooij, Thijs; van Hilst, Jony; Boerma, Djamila; Bonsing, Bert A.; Daams, Freek; van Dam, Ronald M.; Dijkgraaf, Marcel G.; van Eijck, Casper H.; Festen, Sebastiaan; Gerhards, Michael F.; Koerkamp, Bas Groot; van der Harst, Erwin; de Hingh, Ignace H.; Kazemier, Geert; Klaase, Joost; de Kleine, Ruben H.; van Laarhoven, Cornelis J.; Lips, Daan J.; Luyer, Misha D.; Molenaar, I. Quintus; Patijn, Gijs A.; Roos, Daphne; Scheepers, Joris J.; van der Schelling, George P.; Steenvoorde, Pascal; Vriens, Menno R.; Wijsman, Jan H.; Gouma, Dirk J.; Busch, Olivier R.; Hilal, Mohammed Abu; Besselink, Marc G.; de Boer, Marieke T.

    2016-01-01

    Objective:To study the feasibility and impact of a nationwide training program in minimally invasive distal pancreatectomy (MIDP).Summary of Background Data:Superior outcomes of MIDP compared with open distal pancreatectomy have been reported. In the Netherlands (2005 to 2013) only 10% of distal

  18. Improved resolution by mounting of tissue sections for laser microdissection.

    Science.gov (United States)

    van Dijk, M C R F; Rombout, P D M; Dijkman, H B P M; Ruiter, D J; Bernsen, M R

    2003-08-01

    Laser microbeam microdissection has greatly facilitated the procurement of specific cell populations from tissue sections. However, the fact that a coverslip is not used means that the morphology of the tissue sections is often poor. To develop a mounting method that greatly improves the morphological quality of tissue sections for laser microbeam microdissection purposes so that the identification of target cells can be facilitated. Fresh frozen tissue and formalin fixed, paraffin wax embedded tissue specimens were used to test the morphological quality of mounted and unmounted tissue. The mounting solution consisted of an adhesive gum and blue ink diluted in water. Interference of the mounting solution with DNA quality was analysed by the polymerase chain reaction using 10-2000 cells isolated by microdissection from mounted and unmounted tissue. The mounting solution greatly improved the morphology of tissue sections for laser microdissection purposes and had no detrimental effects on the isolation and efficiency of amplification of DNA. One disadvantage was that the mounting solution reduced the cutting efficiency of the ultraviolet laser. To minimise this effect, the mounting solution should be diluted as much as possible. Furthermore, the addition of blue ink to the mounting medium restores the cutting efficiency of the laser. The mounting solution is easy to prepare and apply and can be combined with various staining methods without compromising the quality of the DNA extracted.

  19. Torsion of wandering spleen and distal pancreas

    International Nuclear Information System (INIS)

    Sheflin, J.R.; Lee, C.M.; Kretchmar, K.A.

    1984-01-01

    Wandering spleen is the term applied to the condition in which a long pedicle allows the spleen to lie in an abnormal location. Torsion of a wandering spleen is an unusual cause of an acute abdomen and is rarely diagnosed preoperatively. Associated torsion of the distal pancreas is even more uncommon. The authors describe a patient with torsion of a wandering spleen and distal pancreas, who was correctly diagnosed, and define the merits of the imaging methods used. The initial examination should be 99 /sup m/Tc-sulfur colloid liner-spleen scanning

  20. Osteoblastoma-like osteosarcoma of the distal tibia

    Energy Technology Data Exchange (ETDEWEB)

    Abramovici, Luigia; Steiner, German C. [Department of Pathology and Laboratory Medicine, Hospital for Joint Diseases, New York, NY (United States); Kenan, Samuel [Department of Orthopaedic Oncology Surgery, Hospital for Joint Diseases, New York, NY (United States); Hytiroglou, Prodromos [Aristotle University, Thessaloniki (Greece); Rafii, Mahvash [Department of Radiology, Hospital for Joint Diseases, New York, NY (United States)

    2002-03-01

    We report a case of a 14-year-old boy with an intracompartmental lytic lesion with poorly defined margins in the right distal tibia that was originally treated with curettage and bone grafting. Histologic examination showed an osteoblastic tumor with unusual features, which was found on consultation to be an osteoblastoma-like osteosarcoma, a rare, low-grade variant of osteosarcoma. Subsequently, the patient underwent en bloc resection of the distal tibia, which was replaced with vascularized bone graft and followed by chemotherapy. Two years later, he is alive with lung metastases. (orig.)

  1. Osteoblastoma-like osteosarcoma of the distal tibia

    International Nuclear Information System (INIS)

    Abramovici, Luigia; Steiner, German C.; Kenan, Samuel; Hytiroglou, Prodromos; Rafii, Mahvash

    2002-01-01

    We report a case of a 14-year-old boy with an intracompartmental lytic lesion with poorly defined margins in the right distal tibia that was originally treated with curettage and bone grafting. Histologic examination showed an osteoblastic tumor with unusual features, which was found on consultation to be an osteoblastoma-like osteosarcoma, a rare, low-grade variant of osteosarcoma. Subsequently, the patient underwent en bloc resection of the distal tibia, which was replaced with vascularized bone graft and followed by chemotherapy. Two years later, he is alive with lung metastases. (orig.)

  2. Use of palatally inserted mini-screw for upper molar distalization: A case series

    Directory of Open Access Journals (Sweden)

    Valliollah Arash

    2015-09-01

    Full Text Available  Abstract Reports have shown that molars can be distalized successfully with virtually no orthodontic anchorage loss with an intraosseous anchorage, even with fully erupted second molars. The purpose of this study was evaluating the effects of mini-screws as skeletal anchorage for upper molar distalization. In this case series, three patients needing maxillary first molar distalization, were selected. mini-screw was inserted in the anterior part of the palate. The screws were anchored to the first premolars by transpalatal arch and immediately loaded (150-160 g by 0.018-inch arch-wire and steel open-coil spring to distalize maxillary molars. The skeletal and dental changes were measured on cephalograms obtained before and after distalization. The amount of first molar distalization in the patients was 4 mm with 2°of tipping, 4 mm with 5°of tipping, and 3.5 mm with 2°of tipping respectively. Upper incisors and first premolars were stable during distalization.       

  3. Measured and calculated K-fluorescence effects on the MTF of an amorphous-selenium based CCD x-ray detector.

    Science.gov (United States)

    Hunter, David M; Belev, George; Kasap, Safa; Yaffe, Martin J

    2012-02-01

    Theoretical reasoning suggests that direct conversion digital x-ray detectors based upon photoconductive amorphous-selenium (a-Se) could attain very high values of the MTF (modulation transfer function) at spatial frequencies well beyond 20 cycles mm(-1). One of the fundamental factors affecting resolution loss, particularly at x-ray energies just above the K-edge of selenium (12.66 keV), is the K-fluorescence reabsorption mechanism, wherein energy can be deposited in the detector at locations laterally displaced from the initial x-ray interaction site. This paper compares measured MTF changes above and below the Se K-edge of a CCD based a-Se x-ray detector with theoretical expectations. A prototype 25 μm sampling pitch (Nyquist frequency = 20 cycles mm(-1), 200 μm thick a-Se layer based x-ray detector, utilizing a specialized CCD readout device (200 × 400 area array), was used to make edge images with monochromatic x-rays above and below the K-edge of Se. A vacuum double crystal monochromator, exposed to polychromatic x-rays from a synchrotron, formed the monochromatic x-ray source. The monochromaticity of the x-rays was 99% or better. The presampling MTF was determined using the slanted edge method. The theory modeling the MTF performance of the detector includes the basic x-ray interaction physics in the a-Se layer as well as effects related to the operation of the CCD and charge trapping at a blocking layer present at the CCD/a-Se interface. The MTF performance of the prototype a-Se CCD was reduced from the theoretical value prescribed by the basic Se x-ray interaction physics, principally by the presence of a blocking layer. Nevertheless, the K-fluorescence reduction in the MTF was observed, approximately as predicted by theory. For the CCD prototype detector, at five cycles mm(-1), there was a 14% reduction of the MTF, from a value of 0.7 below the K-edge of Se, to 0.6 just above the K-edge. The MTF of an a-Se x-ray detector has been measured using

  4. Evaluation of the Accuracy of the Dark Frame Subtraction Method in CCD Image Processing

    National Research Council Canada - National Science Library

    Levesque, Martin P; Lelievre, Mario

    2007-01-01

    .... This method is frequently used for removing the image background gradient (a thermal artefact) in CCD images. This report demonstrates that this method may not be suitable for the detection of objects with very low signal-to-noise ratio...

  5. Laparoscopic radical nephroureterectomy: dilemma of the distal ureter.

    Science.gov (United States)

    Steinberg, Jordan R; Matin, Surena F

    2004-03-01

    Laparoscopic nephroureterectomy has recently emerged as a safe, minimally invasive approach to upper tract urothelial cancers. The most controversial and challenging feature of laparoscopic nephroureterectomy is the management of the distal ureter. We review the most common methods of managing the distal ureter, with emphasis on contemporary oncologic outcomes, indications, advantages, and disadvantages. There are currently in excess of five different approaches to the lower ureter. These techniques often combine features of endoscopic, laparoscopic, or open management. They include open excision, a transvesical laparoscopic detachment and ligation technique, laparoscopic stapling of the distal ureter and bladder cuff, the "pluck" technique, and ureteral intussusception. Each technique has distinct advantages and disadvantages, differing not only in technical approach, but oncological principles as well. While the existing published data do not overwhelmingly support one approach over the others, the open approach remains one of the most reliable and oncologically sound procedures. The principles of surgical oncology dictate that a complete, en-bloc resection, with avoidance of tumor seeding, remains the preferred treatment of all urothelial cancers. The classical open technique of securing the distal ureter and bladder cuff achieves this principle and has withstood the test of time. Transvesical laparoscopic detachment and ligation is an oncologically valid approach in patients without bladder tumors, but is limited by technical considerations. The laparoscopic stapling technique maintains a closed system but risks leaving behind ureteral and bladder cuff segments. Both transurethral resection of the ureteral orifice (pluck) and intussusception techniques should be approached with caution, as the potential for tumor seeding exists. Additional long-term comparative outcomes are needed to solve the dilemma of the distal ureter.

  6. Simultaneous bilateral distal biceps tendon repair: case report

    Directory of Open Access Journals (Sweden)

    Thiago Medeiros Storti

    Full Text Available ABSTRACT Simultaneous bilateral rupture of the distal biceps tendon is a rare clinical entity, seldom reported in the literature and with unclear therapeutic setting. The authors report the case of a 39-year-old white man who suffered a simultaneous bilateral rupture while working out. When weightlifting with elbows at 90° of flexion, he suddenly felt pain on the anterior aspect of the arms, coming for evaluation after two days. He presented bulging contour of the biceps muscle belly and ecchymosis in the antecubital fossa, extending distally to the medial aspect of the forearm, as well as a marked decrease of supination strength and pain in active elbow flexion. MRI confirmed the rupture with retraction of the distal biceps bilaterally. The authors opted for performing the tendon repairs simultaneously through the double incision technique and fixation to the bicipital tuberosity with anchors. The patient progressed quite well, with full return to labor and sports activities, being satisfied with the result after two years of surgery. In the literature search, few reports of simultaneous bilateral rupture of the distal biceps were retrieved, with only one treated in the acute phase of injury. Therefore, the authors consider this procedure to be a good option to solve this complex condition.

  7. Simultaneous bilateral distal biceps tendon repair: case report.

    Science.gov (United States)

    Storti, Thiago Medeiros; Paniago, Alexandre Firmino; Faria, Rafael Salomon Silva

    2017-01-01

    Simultaneous bilateral rupture of the distal biceps tendon is a rare clinical entity, seldom reported in the literature and with unclear therapeutic setting. The authors report the case of a 39-year-old white man who suffered a simultaneous bilateral rupture while working out. When weightlifting with elbows at 90° of flexion, he suddenly felt pain on the anterior aspect of the arms, coming for evaluation after two days. He presented bulging contour of the biceps muscle belly and ecchymosis in the antecubital fossa, extending distally to the medial aspect of the forearm, as well as a marked decrease of supination strength and pain in active elbow flexion. MRI confirmed the rupture with retraction of the distal biceps bilaterally. The authors opted for performing the tendon repairs simultaneously through the double incision technique and fixation to the bicipital tuberosity with anchors. The patient progressed quite well, with full return to labor and sports activities, being satisfied with the result after two years of surgery. In the literature search, few reports of simultaneous bilateral rupture of the distal biceps were retrieved, with only one treated in the acute phase of injury. Therefore, the authors consider this procedure to be a good option to solve this complex condition.

  8. Limited distal organelles and synaptic function in extensive monoaminergic innervation.

    Science.gov (United States)

    Tao, Juan; Bulgari, Dinara; Deitcher, David L; Levitan, Edwin S

    2017-08-01

    Organelles such as neuropeptide-containing dense-core vesicles (DCVs) and mitochondria travel down axons to supply synaptic boutons. DCV distribution among en passant boutons in small axonal arbors is mediated by circulation with bidirectional capture. However, it is not known how organelles are distributed in extensive arbors associated with mammalian dopamine neuron vulnerability, and with volume transmission and neuromodulation by monoamines and neuropeptides. Therefore, we studied presynaptic organelle distribution in Drosophila octopamine neurons that innervate ∼20 muscles with ∼1500 boutons. Unlike in smaller arbors, distal boutons in these arbors contain fewer DCVs and mitochondria, although active zones are present. Absence of vesicle circulation is evident by proximal nascent DCV delivery, limited impact of retrograde transport and older distal DCVs. Traffic studies show that DCV axonal transport and synaptic capture are not scaled for extensive innervation, thus limiting distal delivery. Activity-induced synaptic endocytosis and synaptic neuropeptide release are also reduced distally. We propose that limits in organelle transport and synaptic capture compromise distal synapse maintenance and function in extensive axonal arbors, thereby affecting development, plasticity and vulnerability to neurodegenerative disease. © 2017. Published by The Company of Biologists Ltd.

  9. Fractures of the distal radius in children: A retrospective evaluation

    Directory of Open Access Journals (Sweden)

    Selma Yazıcı

    2012-06-01

    Full Text Available Objectives: This study designed to evaluate the resultsof treatment, closed reduction and percutaneous wires, ofthe distal radius fractures in children.Materials and methods: A retrospective analysis wascarried out in children aged between 5-15 years who presentedwith a displaced fracture of the distal radius to ourhospital. They were initially treated with closed reductionand cast immobilization. If the fractures redisplaced treatedby percutaneous Kirschner (K- wire with scope undera general anaesthesia.Results: Totally 104 patients, who have distal radius fractureswere treated by closed reduction and immobilizationin a plaster cast. 13 patient who have distal radiusfractures were treated by closed reduction under generalanaesthesia and fixed by percutaneous Kirschner (K-wire. Patients with impaired the alignment of the fracturein late period were usually completely displaced fractures.(n=5, 4,3%, in early period, completely displaced fractures(n=5, 4,3% are superior to partial displaced fractures(n=2, 1,7%.Conclusion: In our study, when children with distal radiusfracture first come, they were treated by closed reductionand immobilization in a plaster cast. We thought that inredisplaced fractures patients were suitable for the closedreduction with percutaneous wire treatment.

  10. Flow distortion on boom mounted cup anemometers

    DEFF Research Database (Denmark)

    Lindelöw, Per Jonas Petter; Friis Pedersen, Troels; Gottschall, Julia

    In this report we investigate on wind direction dependent errors in the measurement of the horizontal wind speed by boom mounted cup anemometers. The boom mounting on the studied lattice tower is performed according to IEC standard design rules, yet, larger deviations than predicted by flow models...... are observed. The errors on the measurements are likely caused by an underestimation of the flow distortions around the tower. In this paper an experimental method for deriving a correction formula and an in-field calibration is suggested. The method is based on measurements with two cup anemometers mounted...

  11. The role of the potato (Solanum tuberosum) CCD8 gene in stolon and tuber development.

    Science.gov (United States)

    Pasare, Stefania A; Ducreux, Laurence J M; Morris, Wayne L; Campbell, Raymond; Sharma, Sanjeev K; Roumeliotis, Efstathios; Kohlen, Wouter; van der Krol, Sander; Bramley, Peter M; Roberts, Alison G; Fraser, Paul D; Taylor, Mark A

    2013-06-01

    · Strigolactones (SLs) are a class of phytohormones controlling shoot branching. In potato (Solanum tuberosum), tubers develop from underground stolons, diageotropic stems which originate from basal stem nodes. As the degree of stolon branching influences the number and size distribution of tubers, it was considered timely to investigate the effects of SL production on potato development and tuber life cycle. · Transgenic potato plants were generated in which the CAROTENOID CLEAVAGE DIOXYGENASE8 (CCD8) gene, key in the SL biosynthetic pathway, was silenced by RNA interference (RNAi). · The resulting CCD8-RNAi potato plants showed significantly more lateral and main branches than control plants, reduced stolon formation, together with a dwarfing phenotype and a lack of flowering in the most severely affected lines. New tubers were formed from sessile buds of the mother tubers. The apical buds of newly formed transgenic tubers grew out as shoots when exposed to light. In addition, we found that CCD8 transcript levels were rapidly downregulated in tuber buds by the application of sprout-inducing treatments. · These results suggest that SLs could have an effect, solely or in combination with other phytohormones, in the morphology of potato plants and also in controlling stolon development and maintaining tuber dormancy. © 2013 The Authors. New Phytologist © 2013 New Phytologist Trust.

  12. Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries

    International Nuclear Information System (INIS)

    Lee, Wan; Lee, Byung Do

    2003-01-01

    The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p>0.05). These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  13. Intersphincteric Resection and Coloanal Anastomosis in Treatment of Distal Rectal Cancer

    OpenAIRE

    Cipe, Gokhan; Muslumanoglu, Mahmut; Yardimci, Erkan; Memmi, Naim; Aysan, Erhan

    2012-01-01

    In the treatment of distal rectal cancer, abdominoperineal resection is traditionally performed. However, the recognition of shorter safe distal resection line, intersphincteric resection technique has given a chance of sphincter-saving surgery for patients with distal rectal cancer during last two decades and still is being performed as an alternative choice of abdominoperineal resection. The first aim of this study is to assess the morbidity, mortality, oncological, and functional outcomes ...

  14. Distal antebrachial fractures in toy-breed dogs

    International Nuclear Information System (INIS)

    Muir, P.

    1997-01-01

    Antebrachial fractures account for approximately 17% of all canine fractures, with motor vehicle trauma cited as one of the primary causes. However, antebrachial fractures in toy-breed dogs are often sustained after apparently minimal trauma, such as jumping or falling, and are usually distal. The cause of antebrachial fractures in toy breeds is not well understood. Complications after treatment of distal antebrachial fractures in toy-breed dogs, including delayed union, nonunion, and malunion, are common and are potentially serious because they may necessitate limb amputation. This article reports on distal antebrachial fractures in 26 toy-breed dogs that wee presented to the University of California, Davis, Veterinary Medical Teaching Hospital from April 1987 to March 1996. The author found that (1) these fractures typically occur in growing or adolescent dogs; (2) the presence of complications of union is typically associated with prior treatment using intramedullary pinning or external coaptation; and (3) successful healing of this type of fracture is obtained via rigid stabilization with bone plating in combination with cancellous bone autograft

  15. Ultrasound demonstration of distal biceps tendon bifurcation: normal and abnormal findings

    International Nuclear Information System (INIS)

    Tagliafico, Alberto; Capaccio, Enrico; Derchi, Lorenzo E.; Martinoli, Carlo; Michaud, Johan

    2010-01-01

    We demonstrate the US appearance of the distal biceps tendon bifurcation in normal cadavers and volunteers and in those affected by various disease processes. Three cadaveric specimens, 30 normal volunteers, and 75 patients were evaluated by means of US. Correlative MR imaging was obtained in normal volunteers and patients. In all cases US demonstrated the distal biceps tendon shaped by two separate tendons belonging to the short and long head of the biceps brachii muscle. Four patients had a complete rupture of the distal insertion of the biceps with retraction of the muscle belly. Four patients had partial tear of the distal biceps tendon with different US appearance. In two patients the partial tear involved the short head of the biceps brachii tendon, while in the other two patients, the long head was involved. Correlative MR imaging is also presented both in normal volunteers and patients. US changed the therapeutic management in the patients with partial tears involving the LH of the biceps. This is the first report in which ultrasound considers the distal biceps tendon bifurcation in detail. Isolated tears of one of these components can be identified by US. Knowledge of the distal biceps tendon bifurcation ultrasonographic anatomy and pathology has important diagnostic and therapeutic implications. (orig.)

  16. Transducer-Mounting Fixture

    Science.gov (United States)

    Spiegel, Kirk W.

    1990-01-01

    Transducer-mounting fixture holds transducer securely against stud. Projects only slightly beyond stud after installation. Flanged transducer fits into fixture when hinged halves open. When halves reclosed, fixture tightened onto threaded stud until stud makes contact with transducer. Knurled area on fixture aids in tightening fixture on stud.

  17. Development of photoelectric balanced car based on the linear CCD sensor

    Directory of Open Access Journals (Sweden)

    Wang Feng

    2016-01-01

    Full Text Available The smart car is designed based on Freescale’s MC9S12XS128 and a linear CCD camera. The linear CCD collects the road information and sends it to MCU through the operational amplifier. The PID control algorithm, the proportional–integral–derivative control algorithm, is adopted synthetically to control the smart car. First, the smart car’s inclination and angular velocity are detect through the accelerometers and gyro sensors, then the PD control algorithm, the proportional–derivative control algorithm, is employed to make the smart car have the ability of two-wheeled self-balancing. Second, the speed of wheel obtained by the encoder is fed back to the MCU by way of pulse signal, then the PI control algorithm, the proportional–integral control algorithm, is employed to make the speed of smart car reach the set point in the shortest possible time and stabilize at the set point. Finally, the PD control algorithm is used to regulate the smart car’s turning angle to make the smart car respond quickly while the smart car is passing the curve path. The smart car can realize the self-balancing control of two wheels and track automatically the black and while lines to march.

  18. An LOD with improved breakdown voltage in full-frame CCD devices

    Science.gov (United States)

    Banghart, Edmund K.; Stevens, Eric G.; Doan, Hung Q.; Shepherd, John P.; Meisenzahl, Eric J.

    2005-02-01

    In full-frame image sensors, lateral overflow drain (LOD) structures are typically formed along the vertical CCD shift registers to provide a means for preventing charge blooming in the imager pixels. In a conventional LOD structure, the n-type LOD implant is made through the thin gate dielectric stack in the device active area and adjacent to the thick field oxidation that isolates the vertical CCD columns of the imager. In this paper, a novel LOD structure is described in which the n-type LOD impurities are placed directly under the field oxidation and are, therefore, electrically isolated from the gate electrodes. By reducing the electrical fields that cause breakdown at the silicon surface, this new structure permits a larger amount of n-type impurities to be implanted for the purpose of increasing the LOD conductivity. As a consequence of the improved conductance, the LOD width can be significantly reduced, enabling the design of higher resolution imaging arrays without sacrificing charge capacity in the pixels. Numerical simulations with MEDICI of the LOD leakage current are presented that identify the breakdown mechanism, while three-dimensional solutions to Poisson's equation are used to determine the charge capacity as a function of pixel dimension.

  19. An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate

    International Nuclear Information System (INIS)

    Nohtomi, Akihiro; Kurihara, Ryosuke; Kinoshita, Hiroyuki; Honda, Soichiro; Tokunaga, Masaaki; Uno, Heita; Shinsho, Kiyomitsu; Wakabayashi, Genichiro; Koba, Yusuke; Fukunaga, Junichi; Umezu, Yoshiyuki; Nakamura, Yasuhiko; Ohga, Saiji

    2016-01-01

    In our previous paper, the self-activation of an NaI scintillator had been successfully utilized for detecting photo-neutrons around a high-energy X-ray radiotherapy machine; individual optical pulses from the self-activated scintillator are read-out by photo sensors such as a photomultiplier tube (PMT). In the present work, preliminary observations have been performed in order to apply a direct CCD read-out technique to the self-activation method with a CsI scintillator plate using a Pu-Be source and a 10-MV linac. In conclusion, it has been revealed that the CCD read-out technique is applicable to neutron measurement around a high-energy X-ray radiotherapy machine with the self-activation of a CsI plate. Such application may provide a possibility of novel method for simple neutron dose-distribution measurement. - Highlights: • Preliminary observations have been performed by a CCD for the CsI self-activation method. • It has been revealed that the CCD read-out technique is applicable to neutron measurement. • Such application may provide a novel method for simple neutron distribution measurement.

  20. An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate

    Energy Technology Data Exchange (ETDEWEB)

    Nohtomi, Akihiro, E-mail: nohtomi@hs.med.kyushu-u.ac.jp [Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Kurihara, Ryosuke; Kinoshita, Hiroyuki; Honda, Soichiro; Tokunaga, Masaaki; Uno, Heita [Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Shinsho, Kiyomitsu [Graduate School of Human Sciences, Tokyo Metropolitan University, 7-2-10 Higashi-oku, Arakawa-ku, Tokyo 116-8551 (Japan); Wakabayashi, Genichiro [Atomic Energy Research Institute, Kinki University, 3-4-1 Kowakae, Higashiosaka-shi, Osaka 577-8502 (Japan); Koba, Yusuke [National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba-shi, Chiba 263-8555 (Japan); Fukunaga, Junichi; Umezu, Yoshiyuki; Nakamura, Yasuhiko [Department of Radiology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Ohga, Saiji [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)

    2016-10-01

    In our previous paper, the self-activation of an NaI scintillator had been successfully utilized for detecting photo-neutrons around a high-energy X-ray radiotherapy machine; individual optical pulses from the self-activated scintillator are read-out by photo sensors such as a photomultiplier tube (PMT). In the present work, preliminary observations have been performed in order to apply a direct CCD read-out technique to the self-activation method with a CsI scintillator plate using a Pu-Be source and a 10-MV linac. In conclusion, it has been revealed that the CCD read-out technique is applicable to neutron measurement around a high-energy X-ray radiotherapy machine with the self-activation of a CsI plate. Such application may provide a possibility of novel method for simple neutron dose-distribution measurement. - Highlights: • Preliminary observations have been performed by a CCD for the CsI self-activation method. • It has been revealed that the CCD read-out technique is applicable to neutron measurement. • Such application may provide a novel method for simple neutron distribution measurement.

  1. Locking plates in distal humerus fractures: study of 43 patients

    Directory of Open Access Journals (Sweden)

    Gupta Rakesh Kumar

    2013-08-01

    Full Text Available 【Abstract】Objective: The treatment of multi-fragmentary, intraarticular fractures of the distal humerus is difficult, even in young patients with bone of good quality. Small distal fragment, diminished bone mineral quality and increased trauma-associated joint destruction make stable joint reconstruction more problematic. The anatomically preshaped locking plates allow angular stable fixation for these complex fractures. We evaluated functional results of patients treated with open reduction and internal fixation with distal humerus locking plates for complex distal hu-merus fractures. Methods: Forty-three consecutive patients with ar-ticular fractures of the distal humerus were treated by open reduction and internal fixation with AO distal humerus plate system and locking reconstruction plates. Forty patients were available for the final outcome analysis. According to AO/ASIF classification, there were 2 cases of type A2, 4 cases of type A3, 1 case of type B1, 1 case of type B2, 14 cases of type C1, 7 cases of type C2 and 11 cases of type C3. Open reduction with triceps splitting technique was used in all patients. The clinical and radiographic follow-up was performed and outcome measures included pain assessment, range of motion, and Mayo elbow performance score. Results: Forty patients were available for the final outcome analysis. There were 29 males and 11 females with an average age of 38.4 years (18-73 years. Clinical and ra-diological consolidation of the fracture was observed in all cases at an average of 11.6 weeks (9-14 weeks. The average follow-up was 12 months (10-18 months. Using the Mayo elbow performance score the results obtained were graded as excellent or good results in 33 patients (82.5%. One pa-tient had superficial infection, and 4 had myositis ossificans. There were no cases of primary malposition or secondary displacement, implant failure or ulnar neuropathy. Conclusion: Anatomically preshaped distal humerus locking

  2. 49 CFR 571.212 - Standard No. 212; Windshield mounting.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Standard No. 212; Windshield mounting. 571.212... Motor Vehicle Safety Standards § 571.212 Standard No. 212; Windshield mounting. S1. Scope. This standard..., under the conditions of S6, the windshield mounting of the vehicle shall retain not less than the...

  3. Clinical and non-clinical aspects of distal radioulnar joint instability

    NARCIS (Netherlands)

    Wijffels, M.; Brink, P.R.G.; Schipper, I.

    2012-01-01

    Untreated distal radioulnar joint (DRUJ) injuries can give rise to long lasting complaints. Although common, diagnosis and treatment of DRUJ injuries remains a challenge. The articulating anatomy of the distal radius and ulna, among others, enables an extensive range of forearm pronosupination

  4. Laser jamming experiment of varifocal colour CCD imaging system%变焦彩色CCD成像系统的激光干扰实验

    Institute of Scientific and Technical Information of China (English)

    汤伟; 王锐; 王挺峰; 郭劲

    2017-01-01

    Out-field laser jamming experiment of varifocal colour CCD imaging system irradiated by semiconductor laser was done.Laser jamming effects of colour CCD imaging system with different focal lengths were measured.Laser jamming model was set-up,and theoretical proving and analysis on experimental results were completed.Theorical and experimental results show that laser jamming effect of colour CCD imaging system irradiated by 750 nm laser is obvious,and CCD surface appears obvious light saturation and crosstalk phenomena.In the same initial laser irradiating conduction,laser power truncated by the aperture gradually decreases with increase of focal length f,and light saturation area on the CCD surface gradually increases.When focal length f of colour CCD imaging system is 17 mm,light saturation area on the CCD surface is 0.33 mm×0.29 mm.While focal length f of colour CCD imaging system increases to 120 mm,light saturation area on the CCD surface is 1.8 mm×1.2 mm.Simulation results are coincident with experimental results,and it proves laser jamming model is correct.The conclusions have a reference value for colour CCD in the practical application.%开展了变焦彩色CCD成像系统的激光外场干扰实验,测得了半导体激光(750 nm)对变焦距(17~187 mm)彩色CCD相机的干扰效果;同时利用典型的激光干扰CCD模型,完成了对实验结果的验证与理论分析.理论与实验结果表明:750 nm激光对彩色CCD成像系统的干扰效果明显,CCD靶面出现了明显的光饱和和串扰现象;在激光辐照条件相同情况下,光学系统焦距f越大,被光阑截断的激光就越少,到靶的激光功率密度就越高,CCD靶面的光饱和面积就越大;光学系统焦距f为17mm时,CCD靶面的光饱和面积为0.33 mm×0.29 mm,而当光学系统焦距f增大至120 mm时,CCD靶面的光饱和面积为1.8 mm×1.2 mm.仿真结果与实验结果基本一致,证明了理论模型的正确性.研究结果将对CCD器件的实际应用具有一定的指导意义.

  5. Surgical treatment of distal biceps tendon rupture: a case report

    Directory of Open Access Journals (Sweden)

    Cristina N. Cozma

    2017-11-01

    Full Text Available Objectives. Distal biceps tendon rupture affects the functional upperextremity movement, impairing supination and flexion strength. According to age, profession and additional risks treatment might be nonoperative or surgical. Methods. We describe the case of a 43 years old male patient who sustained an injury to his right distal biceps and was diagnosed with acute right distal biceps rupture. Surgical treatment was decided and biceps tendon was reinserted to the radius tuberosity using a combination of a cortical button fixation associated with an interference screw. Results. Postoperative functional result was favorable with no complications and with no movement limitation after one month. Conclusions. When possible, distal biceps tendon repair should be realized surgically because this permits restoring of the muscle strength to near normal levels with no loss of motion. Nerve complications are common; therefore the surgery should be realized by experienced upper extremity surgeons.

  6. Distal protection filter device efficacy with carotid artery stenting: comparison between a distal protection filter and a distal protection balloon.

    Science.gov (United States)

    Iko, Minoru; Tsutsumi, Masanori; Aikawa, Hiroshi; Matsumoto, Yoshihisa; Go, Yoshinori; Nii, Kouhei; Abe, Gorou; Ye, Iwae; Nomoto, Yasuyuki; Kazekawa, Kiyoshi

    2013-01-01

    This retrospective study aimed to compare the effectiveness of the embolization prevention mechanism of two types of embolic protection device (EPD)-a distal protection balloon (DPB) and a distal protection filter (DPF). Subjects were 164 patients scheduled to undergo carotid artery stenting: a DPB was used in 82 cases (DPB group) from April 2007 until June 2010, and a DPF was used in 82 cases (DPF group) from July 2010 to July 2011. Rates of positive findings on postoperative diffusion-weighted imaging (DWI) and stroke incidence were compared. Positive postoperative DWI results were found in 34 cases in the DPB group (41.4 %), but in only 22 cases in the DPF group (26.8 %), and there was only a small significant difference within the DPF group. In the DPB group, there was one case of transient ischemic attack (TIA) (1.2 %) and four cases of brain infarction (2 minor strokes, 2 major strokes; 4.9 %), compared to the DFP group with one case of TIA (1.2 %) and no cases of minor or major strokes. In this study, significantly lower rates of occurrence of DWI ischemic lesions and intraoperative embolization were associated with use of the DPF compared to the DPB.

  7. New active machine tool drive mounting on the frame

    Directory of Open Access Journals (Sweden)

    Švéda J.

    2007-10-01

    Full Text Available The paper deals with the new active mounting of the machine tool drives. The commonly used machine tools are at this time mainly equipped with fix-mounting of the feed drives. This structure causes full transmission of the force shocks to the machine bed and thereby restricts the dynamic properties of the motion axis and the whole machine. The spring-mounting of the feed drives is one of the possibilities how to partially suppress the vibrations. The force that reacts to the machine tool bed is transformed thereby the vibrations are lightly reduced. Unfortunately the transformation is not fully controlled. The new active mounting of the machine tool drives allows to fully control the force behaviour that react to the machine body. Thereby the number of excited frequencies on the machine tool bed is significantly reduced. The active variant of the feed drive mounting is characterized by the synergistic cooperation between two series-connected actuators (“motor on motor”. The paper briefly describes design, control techniques and optimization of the feed drives with the new active mounting conception.

  8. Organization and processes of the BN-600 reactor mounting

    International Nuclear Information System (INIS)

    Dubrovin, E.Z.; Karpenko, V.N.; Takhtaulov, V.M.

    1982-01-01

    Structural peculiarities of the BN-600 reactor plant are considered. Experience of metal structure mounting inside the reactor vessel has been analysed. Recommendations on the improvements on the organization of the thermal mechanical equipment mounting are given. It is concluded that the consideration of these recommendations will permit to reduce expenditures of labour by 10-40% for the mounting

  9. 46 CFR 61.05-15 - Boiler mountings and attachments.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Boiler mountings and attachments. 61.05-15 Section 61.05... TESTS AND INSPECTIONS Tests and Inspections of Boilers § 61.05-15 Boiler mountings and attachments. (a....05-10. (b) Each stud or bolt for each boiler mounting that paragraph (c) of this section requires to...

  10. Image quality in conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Bautz, W.; Saebel, M.

    2000-01-01

    Purpose: Comparison of image quality between conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system, two digital storage plate systems and two digital systems in CCD-technique. Additionally, the radiograms of one digital phosphor storage plate system were post-processed emphasizing contrast and included in the comparison. Results: The detectability of details was the best with the digital mammography in CCD-technique in comparison with the conventional film screen technique resp. digital phosphor storage plate in magnification technique. Conclusions: Based on these results there is the possibility to replace the conventional film screen system by further studies - this has to be confirmed. (orig.) [de

  11. Direct and indirect signal detection of 122 keV photons with a novel detector combining a pnCCD and a CsI(Tl) scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Schlosser, D.M., E-mail: dieter.schlosser@pnsensor.de [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Huth, M.; Hartmann, R. [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Abboud, A.; Send, S. [Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany); Conka-Nurdan, T. [Türkisch-Deutsche Universität, Sakinkaya Cad. 86, Beykoz, 34820 Istanbul (Turkey); Shokr, M.; Pietsch, U. [Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany); Strüder, L. [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany)

    2016-01-01

    By combining a low noise fully depleted pnCCD detector with a CsI(Tl) scintillator, an energy-dispersive area detector can be realized with a high quantum efficiency (QE) in the range from below 1 keV to above 100 keV. In direct detection mode the pnCCD exhibits a relative energy resolution of 1% at 122 keV and spatial resolution of less than 75 µm, the pixel size of the pnCCD. In the indirect detection mode, i.e. conversion of the incoming X-rays in the scintillator, the measured energy resolution was about 9–13% at 122 keV, depending on the depth of interaction in the scintillator, while the position resolution, extracted with the help of simulations, was 30 µm only. We show simulated data for incident photons of 122 keV and compare the various interaction processes and relevant physical parameters to experimental results obtained with a radioactive {sup 57}Co source. - Highlights: • Position and energy resolving pnCCD+CsI(Tl) detector for energies from 1-150 keV • Detection in the pnCCD (122keV): 1% energy and <75µm spatial resolution • Detection in the scintillator (122keV): 9-12% energy and ~30µm spatial resolution.

  12. Macromolecular crystallographic results obtained using a 2048x2048 CCD detector at CHESS

    International Nuclear Information System (INIS)

    Thiel, D.J.; Ealick, S.E.; Tate, M.W.; Gruner, S.M.; Eikenberry, E.F.

    1996-01-01

    We present results of macromolecular crystallographic experiments performed at the Cornell High Energy Synchrotron Source (CHESS) with a new CCD-based detector. This detector, installed in January 1995, complements a 1024x1024 CCD detector that has been in continuous operation at CHESS since December 1993. The new detector is based on a 4-port, 2048x2048 pixel CCD that is directly coupled to a Gd 2 O 2 S:Tb phosphor by a 3:1 tapered fiber optic. The active area of the phosphor is a square 82 mm on an edge. The readout time is 7 seconds. In the standard mode of operation, the pixel size at the active area is 41 μm on the edge leading to the capability of resolving approximately 200 orders of diffraction across the detector face. The detector also operates in a 1024x1024 mode in which the pixel size is electronically increased by a factor of 4 in area resulting in smaller data files and faster detector readout but at the expense of spatial resolution. Most of the data that has been collected by this detector has been collected in this mode. Dozens of data sets have been collected by many experimenters using this detector at CHESS during the four month period from its installation until the start of the six-month down period of the storage ring. The capabilities of the detector will be illustrated with results from various crystallographic measurements including experiments in which the recorded diffraction patterns extend in resolution as far as 1 A. The results demonstrate that this detector is capable of collecting data of quality at least equal to that of imaging plates but, in many circumstances, with much greater beamline efficiency. copyright 1996 American Institute of Physics

  13. Radiographic study of distal radial physeal closure in thoroughbred horses

    International Nuclear Information System (INIS)

    Vulcano, L.C.; Mamprim, M.J.; Muniz, L.M.R.; Moreira, A.F.; Luna, S.P.L.

    1997-01-01

    Monthly radiography was performed to study distal radial physeal closure in ten male and ten female Throughbred horses. The height, thoracic circumference and metacarpus circumference were also measured, Distal radial physeal closure time was sooner in females than males, and took 701 +/- 37 and 748 +/- 55 days respectively

  14. Linear and/or curvilinear rail mount system

    Science.gov (United States)

    Thomas, Jackie D. (Inventor); Harris, Lawanna L. (Inventor)

    2012-01-01

    One or more linear and/or curvilinear mounting rails are coupled to a structure. Each mounting rail defines a channel and at least one cartridge assembly is engaged in the channel. Each cartridge assembly includes a housing that slides within the channel. The housing defines a curvilinearly-shaped recess longitudinally aligned with the channel when the housing is in engagement therewith. The cartridge assembly also includes a cleat fitted in the recess for sliding engagement therealong. The cleat can be coupled to a fastener that passes through the mounting rail and the housing when the housing is so-engaged in the channel. The cleat is positioned in the recess by a position of the fastener.

  15. Fotometría de imágenes CCD insuficientemente muestreadas

    Science.gov (United States)

    Ostrov, P. G.

    Se enfrenta el problema de la fotometría de imágenes CCD con una escala inadecuada (fwhm menor o igual que el tamaño de un pixel) y psf fuertemente variable con la posición. Se analiza, en particular, la aplicabilidad de una táctica propuesta por Massey, consistente en eliminar las vecinas débiles (utilizando una psf rudimentaria) para luego efectuar una fotometría de apertura sobre las estrellas brillantes. Se determina, mediante experimentos numéricos, la precisión alcanzada mediante esta técnica.

  16. Distal Embolic Protection for Renal Arterial Interventions

    International Nuclear Information System (INIS)

    Dubel, Gregory J.; Murphy, Timothy P.

    2008-01-01

    Distal or embolic protection has intuitive appeal for its potential to prevent embolization of materials generated during interventional procedures. Distal protection devices (DPDs) have been most widely used in the coronary and carotid vascular beds, where they have demonstrated the ability to trap embolic materials and, in some cases, to reduce complications. Given the frequency of chronic kidney disease in patients with renal artery stenosis undergoing stent placement, it is reasonable to propose that these devices may play an important role in limiting distal embolization in the renal vasculature. Careful review of the literature reveals that atheroembolization does occur during renal arterial interventions, although it often goes undetected. Early experience with DPDs in the renal arteries in patients with suitable anatomy suggests retrieval of embolic materials in approximately 71% of cases and renal functional improvement/stabilization in 98% of cases. The combination of platelet inhibition and a DPD may provide even greater benefit. Given the critical importance of renal functional preservation, it follows that everything that can be done to prevent atheroembolism should be undertaken including the use of DPDs when anatomically feasible. The data available at this time support a beneficial role for these devices

  17. DOUBLE STARS IN THE USNO CCD ASTROGRAPHIC CATALOG

    Energy Technology Data Exchange (ETDEWEB)

    Hartkopf, William I.; Mason, Brian D.; Finch, Charlie T.; Zacharias, Norbert; Wycoff, Gary L.; Hsu, Danley, E-mail: wih@usno.navy.mil, E-mail: bdm@usno.navy.mil, E-mail: finch@usno.navy.mil, E-mail: nz@usno.navy.mil [US Naval Observatory, Washington, DC 20392 (United States)

    2013-10-01

    The newly completed Fourth USNO CCD Astrographic Catalog (UCAC4) has proven to be a rich source of double star astrometry and photometry. Following initial comparisons of UCAC4 results against those obtained by speckle interferometry, the UCAC4 catalog was matched against known double stars in the Washington Double Star Catalog in order to provide additional differential astrometry and photometry for these pairs. Matches to 58,131 pairs yielded 61,895 astrometric and 68,935 photometric measurements. Finally, a search for possible new common proper motion (CPM) pairs was made using new UCAC4 proper motion data; this resulted in 4755 new potential CPM doubles (and an additional 27,718 astrometric and photometric measures from UCAC and other sources)

  18. Contemporary Management of Primary Distal Urethral Cancer.

    Science.gov (United States)

    Traboulsi, Samer L; Witjes, Johannes Alfred; Kassouf, Wassim

    2016-11-01

    Primary urethral cancer is one of the rare urologic tumors. Distal urethral tumors are usually less advanced at diagnosis compared with proximal tumors and have a good prognosis if treated appropriately. Low-stage distal tumors can be managed successfully with a surgical approach in men or radiation therapy in women. There are no clear-cut indications for the choice of the most appropriate treatment modality. Organ-preserving modalities have shown effective and should be used whenever they do not compromise the oncological safety to decrease the physical and psychological trauma of dismemberment or loss of sexual/urinary function. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. 基于线性 CCD 的智能车路径提取与寻迹%Path extraction and tracing of smart car based on linear CCD

    Institute of Scientific and Technical Information of China (English)

    白晋龙

    2016-01-01

    Extraction track information and tracing based on linear CCD is a key link in the development of smart car . This paper first introduced the linear CCD with matters should be noted in the use of the process .Then introduced the black and white border extraction algorithm .The effect of dirt or shadow on boundary extraction is eliminated by using corrosion method .Three kinds of track search methods are proposed .The methods are the center line tracing method , single track tracing method and track prediction method .The advantages and disadvantages of the three methods are compared in detail .Finally ,the author makes use of the single track search method to complete the production of intelligent vehicle ,the use of the limited resources of the Carle microcontroller to ensure that the race is not out of the runw ay .%基于线性CCD提取赛道信息和按照赛道信息控制智能车寻迹是光电组智能车制作中的关键环节。本文首先介绍了线性CCD ,以及使用过程中应该注意的事项,然后介绍了黑白边界提取算法,采用腐蚀算法消除了赛道上污垢或阴影对边界提取的影响,提出了3种赛道寻迹方法,分别为中心线寻迹法、单边寻迹法、赛道预估法,详细比较了3种方法的优缺点,单边寻迹法不仅适用于各种赛道情况,而且处理信息少,占用CPU空间小。最后利用单边寻迹法完成智能车制作,使用飞思卡尔单片机有限的资源保证在不冲出跑道的前提下完成了比赛。

  20. Methods and apparatus for radially compliant component mounting

    Science.gov (United States)

    Bulman, David Edward [Cincinnati, OH; Darkins, Jr., Toby George; Stumpf, James Anthony [Columbus, IN; Schroder, Mark S [Greenville, SC; Lipinski, John Joseph [Simpsonville, SC

    2012-03-27

    Methods and apparatus for a mounting assembly for a liner of a gas turbine engine combustor are provided. The combustor includes a combustor liner and a radially outer annular flow sleeve. The mounting assembly includes an inner ring surrounding a radially outer surface of the liner and including a plurality of axially extending fingers. The mounting assembly also includes a radially outer ring coupled to the inner ring through a plurality of spacers that extend radially from a radially outer surface of the inner ring to the outer ring.

  1. Analysis of fractal dimensions of rat bones from film and digital images

    Science.gov (United States)

    Pornprasertsuk, S.; Ludlow, J. B.; Webber, R. L.; Tyndall, D. A.; Yamauchi, M.

    2001-01-01

    OBJECTIVES: (1) To compare the effect of two different intra-oral image receptors on estimates of fractal dimension; and (2) to determine the variations in fractal dimensions between the femur, tibia and humerus of the rat and between their proximal, middle and distal regions. METHODS: The left femur, tibia and humerus from 24 4-6-month-old Sprague-Dawley rats were radiographed using intra-oral film and a charge-coupled device (CCD). Films were digitized at a pixel density comparable to the CCD using a flat-bed scanner. Square regions of interest were selected from proximal, middle, and distal regions of each bone. Fractal dimensions were estimated from the slope of regression lines fitted to plots of log power against log spatial frequency. RESULTS: The fractal dimensions estimates from digitized films were significantly greater than those produced from the CCD (P=0.0008). Estimated fractal dimensions of three types of bone were not significantly different (P=0.0544); however, the three regions of bones were significantly different (P=0.0239). The fractal dimensions estimated from radiographs of the proximal and distal regions of the bones were lower than comparable estimates obtained from the middle region. CONCLUSIONS: Different types of image receptors significantly affect estimates of fractal dimension. There was no difference in the fractal dimensions of the different bones but the three regions differed significantly.

  2. [NDVI difference rate recognition model of deciduous broad-leaved forest based on HJ-CCD remote sensing data].

    Science.gov (United States)

    Wang, Yan; Tian, Qing-Jiu; Huang, Yan; Wei, Hong-Wei

    2013-04-01

    The present paper takes Chuzhou in Anhui Province as the research area, and deciduous broad-leaved forest as the research object. Then it constructs the recognition model about deciduous broad-leaved forest was constructed using NDVI difference rate between leaf expansion and flowering and fruit-bearing, and the model was applied to HJ-CCD remote sensing image on April 1, 2012 and May 4, 2012. At last, the spatial distribution map of deciduous broad-leaved forest was extracted effectively, and the results of extraction were verified and evaluated. The result shows the validity of NDVI difference rate extraction method proposed in this paper and also verifies the applicability of using HJ-CCD data for vegetation classification and recognition.

  3. One-stage lingual augmented urethroplasty in repair of distal penile ...

    African Journals Online (AJOL)

    E. Elsayed

    Abstract. Objectives: To evaluate the outcome of augmentation of shallow urethral plate by lingual graft in repair of distal penile hypospadias. Patients and methods: Between June 2008 and May 2011, the procedure was performed on 23 patients with mean age 2.3 years (range 1–3). All patients had distal penile ...

  4. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients

    OpenAIRE

    Gupta, Rakesh K.; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2009-01-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-...

  5. First observations from a CCD all-sky spectrograph at Barentsburg (Spitsbergen

    Directory of Open Access Journals (Sweden)

    S. A. Chernouss

    2008-05-01

    Full Text Available A digital CCD all-sky spectrograph was made by the Polar Geophysical Institute (PGI to support IPY activity in auroral research. The device was tested at the Barentsburg observatory of PGI during the winter season of 2005–2006. The spectrograph is based on a cooled CCD and a transmission grating. The main features of this spectrograph are: a wide field of view (~180°, a wide spectral range (380–740 nm, a spectral resolution of 0.6 nm, a background level of about 100 R at 1-min exposure time. Several thousand spectra of nightglow and aurora were recorded during the observation season. It was possible to register both the strong auroral emissions, as well as weak ones. Spectra of aurora, including nitrogen and oxygen molecular and atomic emissions, as well as OH emissions of the nightglow are shown. A comparison has been conducted of auroral spectra obtained by the film all-sky spectral camera C-180-S at Spitsbergen during IGY, with spectra obtained at Barentsburg during the last winter season. The relationship between the red (630.0 nm and green (557.7 nm auroral emissions shows that the green emission is dominant near the minimum of the solar cycle activity (2005–2006. The opposite situation is observed during 1958–1959, with a maximum solar cycle activity.

  6. Pengembangan Metoda Deteksi Rintangan untuk Traktor tanpa Awak Menggunakan Kamera CCD

    Directory of Open Access Journals (Sweden)

    Usman Ahmad

    2012-04-01

    Full Text Available For unmanned tractor guided by global positioning system, ability for eluding obstacles such as trees, big stone, cavity, bund, people, and other objects in the work area is very important in order not to stop the operation.Surrounding detection system using CCD camera makes it possible for unmanned tractor to detect obstacles in front of it realtime. However, with so many different objects that may captured by the camera, it will need a lot of image processing steps that takes a lot of time so it is no longer suitable for realtime detection in application. The proposed research is aimed to develop a simpler obstacle detection method by adding a red laser pointer to the CCD camera used to capture scene in front of the tractor. The red laser light that reflected by an obstacle gives an important information in the image, and the distance of the obstacle could be calculated based on phytagoras theory. The results showed that all obstacles with 1 m distance, 80% obstacles with 2 m distance, and 40% obstacles with 3 m distance could be detected. Obstacles with more than 3 m distances could not be detected due to weak laser light for the distances. The accuracy of distance prediction for all situation is 67.5%, which is still need improvements.

  7. Vertical repositioning accuracy of magnetic mounting systems on 4 articulator models.

    Science.gov (United States)

    Lee, Wonsup; Kwon, Ho-Beom

    2018-03-01

    Research of the ability of a cast mounted on an articulator on maintaining the identical position of a cast mounted on an articulator after repeated repositioning is lacking, despite the possible effects this may have on the occlusion of a mounted cast. The purpose of this in vitro study was to verify and compare the vertical repositioning accuracy of 4 different, commercially available articulator magnetic mounting plate systems. Four articulators and their associated magnetic mounting plates were selected for the study. These were the Artex AR articulator (Amann Girrbach AG), the Denar Mark II articulator (Whip Mix Corp), the Kavo Protar Evo articulator (Kavo Dental GmbH), and the SAM3 articulator (SAM Präzisionstechnik GmbH). Three new magnetic mounting plates were prepared for each articulator system. The repositioning accuracy of each mounting plate was evaluated by comparing the standard deviation of the vertical distances measured between the mounting plate and a laser displacement sensor. The lower arm of the articulator was secured, and the vertical distance was measured by positioning the laser displacement sensor positioned vertically above the mounting plate. Once the vertical distance was measured, the mounting plate was detached from the articulator and reattached manually to prepare for the next measurement. This procedure was repeated 30 times for each of the 3 magnetic mounting plates. Data were analyzed by ANOVA for 2-stage nested design and the Levene test (α=.05). Significant differences were detected among articulator systems and between magnetic mounting plates of the same type. The standard deviations of the measurements made with the Artex AR articulator, Denar Mark II articulator, Kavo Protar Evo articulator, and SAM3 articulator were 0.0027, 0.0308, 0.0214, and 0.0215 mm, respectively. Thus, the repositioning accuracy could be ranked in the order as follows: Artex AR, Kavo Protar Evo, SAM3, and Denar Mark II. The position of the

  8. Internally Mounting Strain Gages

    Science.gov (United States)

    Jett, J. R., Jr.

    1984-01-01

    Technique for mounting strain gages inside bolt or cylinder simultaneously inserts gage, attached dowel segment, and length of expandable tubing. Expandable tubing holds gage in place while adhesive cures, assuring even distribution of pressure on gage and area gaged.

  9. Distal vertebral artery reconstruction when managing vertebrobasilar insufficiency

    Directory of Open Access Journals (Sweden)

    D. M. Galaktionov

    2017-11-01

    Full Text Available This article presents a literature review devoted to the reconstruction of the distal vertebral artery and a clinical case of successful surgical treatment of a patient suffering from vertebrobasilar insufficiency caused by occlusion of the vertebral artery in a proximal segment. The external carotid artery-distal vertebral artery bypass was performed by using the radial artery.Received 27 February 2017. Revised 25 July 2017. Accepted 3 August 2017.Funding: The study did not have sponsorship.Conflict of interest: The authors declare no conflict of interest. 

  10. Neglected Distal Humeral Epiphyseal Injury - Two Case Reports

    Directory of Open Access Journals (Sweden)

    Dr. Pankaj Kumar

    2008-07-01

    Full Text Available Distal humeral epiphyseal separation is an uncommon injury in children, which can be missed or misdiagnosed at initial presentation. Awareness of this injury and appropriate radiological assessment helps in proper management. Neglected cases because of inappropriate diagnosis can result in cubitus varus deformity. Full range of movements of elbow can be achieved if properly diagnosed and managed. We present two cases of neglected distal humeral epiphyseal injury in children that resulted in cubitus varus deformity in one case. Full range of movements was achieved in both cases after proper management.

  11. Distal pancreatectomy and splenectomy: a robotic or LESS approach.

    Science.gov (United States)

    Ryan, Carrie E; Ross, Sharona B; Sukharamwala, Prashant B; Sadowitz, Benjamin D; Wood, Thomas W; Rosemurgy, Alexander S

    2015-01-01

    The role and application of robotic surgery are debated, particularly given the expansion of laparoscopy, especially laparoendoscopic single-site (LESS) surgery. This cohort study was undertaken to delineate differences in outcomes between LESS and robotic distal pancreatectomy and splenectomy. With Institutional Review Board approval, patients undergoing LESS or robotic distal pancreatectomy and splenectomy from September 1, 2012, through December 31, 2014, were prospectively observed, and data were collected. The results are expressed as the median, with the mean ± SD. Thirty-four patients underwent a minimally invasive distal pancreatectomy and splenectomy: 18 with robotic and 16 with LESS surgery. The patients were similar in sex, age, and body mass index. Conversions to open surgery and estimated blood loss were similar. There were two intraoperative complications in the group that underwent the robotic approach. Time spent in the operating room was significantly longer with the robot (297 vs 254 minutes, P = .03), although operative duration (i.e., incision to closure) was not longer (225 vs 190 minutes; P = .15). Of the operations studied, 79% were undertaken for neoplastic processes. Tumor size was 3.5 cm for both approaches; R0 resections were achieved in all patients. Length of stay was similar in the two study groups (5 vs 4 days). There was one 30-day readmission after robotic surgery. Patient outcomes are similar with LESS or robotic distal pancreatectomy and splenectomy. Robotic operations require more time in the operating room. Both are safe and efficacious minimally invasive operations that follow similar oncologic principles for similar tumors, and both should be in the surgeon's armamentarium for distal pancreatectomy and splenectomy.

  12. Application of Evolutionary Computation in Automotive Powertrain Mount Tuning

    Directory of Open Access Journals (Sweden)

    Anab Akanda

    2006-01-01

    Full Text Available Engine mount tuning is a multi-disciplinary exercise since it affects Idle-shake, Road-shake and power-train noise response. Engine inertia is often used as a tuned absorber for controlling suspension resonance related road-shake issues. Last but not least, vehicle ride and handling may also be affected by mount tuning. In this work, Torque-Roll-Axis (TRA decoupling of the rigid powertrain was used as a starting point for mount tuning. Nodal point of flexible powertrain bending was used to define the envelop for transmission mount locations. The frequency corresponding to the decoupled roll mode of the rigid powertrain was then adjusted for idle-shake and road-shake response management.

  13. Distal tibiofibular synostosis in a Nigerian: A case report | Owoeye ...

    African Journals Online (AJOL)

    X-ray of the bones showed an oblique fracture in the distal end of the shaft of fibula which is suggestive of post traumatic tibiofibular synostosis (TFS). Knowledge of distal TFS is important in resolving the puzzle of chronic shin pain of unknown origin and in accurate diagnosis of causes of ankle deformity and malformations.

  14. Dental and skeletal changes after intraoral molar distalization with sectional jig assembly.

    Science.gov (United States)

    Gulati, S; Kharbanda, O P; Parkash, H

    1998-09-01

    The present study was conducted on 10 subjects to evaluate dental and skeletal changes after intraoral molar distalization. The maxillary molars were distalized with a sectional jig assembly. Sentalloy open coil springs were used to exert 150 gm of force for a period of 12 weeks. A modified Nance appliance was the main source of anchorage. The pre- and postdistalization records included dental study casts, clinical photographs, and cephalograms. A total of 665 readings recorded from lateral cephalograms and dental casts were subjected to statistical analysis. The mean distal movement of the first molar was 2.78 mm, which was highly significant (o < 0.001). It moved distally at the rate of 0.86 mm/month. There was clinically some distal tipping (3.50 degrees) and distopalatal rotation (2.40 degrees). These changes were statistically significant (p < 0.001). The second molars accompanied the first molars and moved distally by nearly the same amount. There was 1.00 mm increase in the overjet and 2.60 degrees mesial tip of second premolar. The changes in the facial skeleton and dentition bases were minimal and statistically not significant. However, there was clockwise rotation of the mandible of 1.30 degrees that was statistically significant. This was the result of molar extrusion (1.60 mm).

  15. Social Support Contributes to Outcomes following Distal Radius Fractures

    Directory of Open Access Journals (Sweden)

    Caitlin J. Symonette

    2013-01-01

    Full Text Available Background. Distal radius fractures are the most common fracture of the upper extremity and cause variable disability. This study examined the role of social support in patient-reported pain and disability at one year following distal radius fracture. Methods. The Medical Outcomes Study Social Support Survey was administered to a prospective cohort of 291 subjects with distal radius fractures at their baseline visit. Pearson correlations and stepwise linear regression models (F-to-remove 0.10 were used to identify whether social support contributes to wrist fracture outcomes. The primary outcome of pain and disability at one year was measured using the Patient Rated Wrist Evaluation. Results. Most injuries were low energy (67.5% and were treated nonoperatively (71.9%. Pearson correlation analysis revealed that higher reported social support correlated with improved Patient Rated Wrist Evaluation scores at 1 year, r(n=181=-0.22, P<0.05. Of the subscales within the Social Support Survey, emotional/informational support explained a significant proportion of the variance in 1-year Patient Rated Wrist Evaluation scores, R2=4.7%, F (1, 181 = 9.98, P<0.05. Conclusion. Lower emotional/informational social support at the time of distal radius fracture contributes a small but significant percentage to patient-reported pain and disability outcomes.

  16. The research of digital circuit system for high accuracy CCD of portable Raman spectrometer

    Science.gov (United States)

    Yin, Yu; Cui, Yongsheng; Zhang, Xiuda; Yan, Huimin

    2013-08-01

    The Raman spectrum technology is widely used for it can identify various types of molecular structure and material. The portable Raman spectrometer has become a hot direction of the spectrometer development nowadays for its convenience in handheld operation and real-time detection which is superior to traditional Raman spectrometer with heavy weight and bulky size. But there is still a gap for its measurement sensitivity between portable and traditional devices. However, portable Raman Spectrometer with Shell-Isolated Nanoparticle-Enhanced Raman Spectroscopy (SHINERS) technology can enhance the Raman signal significantly by several orders of magnitude, giving consideration in both measurement sensitivity and mobility. This paper proposed a design and implementation of driver and digital circuit for high accuracy CCD sensor, which is core part of portable spectrometer. The main target of the whole design is to reduce the dark current generation rate and increase signal sensitivity during the long integration time, and in the weak signal environment. In this case, we use back-thinned CCD image sensor from Hamamatsu Corporation with high sensitivity, low noise and large dynamic range. In order to maximize this CCD sensor's performance and minimize the whole size of the device simultaneously to achieve the project indicators, we delicately designed a peripheral circuit for the CCD sensor. The design is mainly composed with multi-voltage circuit, sequential generation circuit, driving circuit and A/D transition parts. As the most important power supply circuit, the multi-voltage circuits with 12 independent voltages are designed with reference power supply IC and set to specified voltage value by the amplifier making up the low-pass filter, which allows the user to obtain a highly stable and accurate voltage with low noise. What's more, to make our design easy to debug, CPLD is selected to generate sequential signal. The A/D converter chip consists of a correlated

  17. Flat mount preparation for observation and analysis of zebrafish embryo specimens stained by whole mount in situ hybridization.

    Science.gov (United States)

    Cheng, Christina N; Li, Yue; Marra, Amanda N; Verdun, Valerie; Wingert, Rebecca A

    2014-07-17

    The zebrafish embryo is now commonly used for basic and biomedical research to investigate the genetic control of developmental processes and to model congenital abnormalities. During the first day of life, the zebrafish embryo progresses through many developmental stages including fertilization, cleavage, gastrulation, segmentation, and the organogenesis of structures such as the kidney, heart, and central nervous system. The anatomy of a young zebrafish embryo presents several challenges for the visualization and analysis of the tissues involved in many of these events because the embryo develops in association with a round yolk mass. Thus, for accurate analysis and imaging of experimental phenotypes in fixed embryonic specimens between the tailbud and 20 somite stage (10 and 19 hours post fertilization (hpf), respectively), such as those stained using whole mount in situ hybridization (WISH), it is often desirable to remove the embryo from the yolk ball and to position it flat on a glass slide. However, performing a flat mount procedure can be tedious. Therefore, successful and efficient flat mount preparation is greatly facilitated through the visual demonstration of the dissection technique, and also helped by using reagents that assist in optimal tissue handling. Here, we provide our WISH protocol for one or two-color detection of gene expression in the zebrafish embryo, and demonstrate how the flat mounting procedure can be performed on this example of a stained fixed specimen. This flat mounting protocol is broadly applicable to the study of many embryonic structures that emerge during early zebrafish development, and can be implemented in conjunction with other staining methods performed on fixed embryo samples.

  18. Proximal and distal alignment of normal canine femurs: A morphometric analysis.

    Science.gov (United States)

    Kara, Mehmet Erkut; Sevil-Kilimci, Figen; Dilek, Ömer Gürkan; Onar, Vedat

    2018-05-01

    Many researchers are interested in femoral conformation because most orthopaedic problems of the long bones occur in the femur and its joints. The neck-shaft (NSA) and the anteversion (AVA) angles are good predictors for understanding the orientation of the proximal end of the femur. The varus (aLDFA) and procurvatum (CDFA) angles have also been used to understand the orientation of the distal end of the femur. The purposes of this study were to investigate the relationship between the proximal and distal angles of the femur and to compare the distal femoral angles in male and female dogs in order to investigate the sexual dimorphism. The measurements of normal CDFAs, which have not been previously reported, may also provide a database of canine distal femoral morphology. A total of 75 cleaned healthy femora from different breeds or mixed breed of dogs were used. The three-dimensional images were reconstructed from computed tomographic images. The AVA, NSA, aLDFA and CDFA were measured on the 3D images. The correlation coefficients were calculated among the measured angles. The distal femoral angles were also compared between male and female femora. The 95% confidence intervals of the AVA and the NSA were calculated to be 24.22°-29.50° and 144.97°-147.50°, respectively. The 95% confidence intervals of the aLDFA and the CDFA for all studied dogs were 92.62°-94.08° and 89.09°-91.94°, respectively. The NSA showed no correlation with either the aLDFA or CDFA. There was a weak inverse correlation between the AVA and CDFA and a weak positive correlation between the AVA and aLDFA. The differences in the aLDFA and CDFA measurements between male and female dog were not significant. In conclusion, femoral version, regardless of the plane, might have little influence on distal femoral morphology in normal dogs. Besides this, there is no evidence of a sexual dimorphism in the varus and procurvatum angles of the dog distal femur. The data from this study may be used in

  19. Analysis of total visual and ccd v-broadband observation of comet c/1995 o1 (hale-bopp): 1995-2003

    Science.gov (United States)

    de Almeida, A. A.; Boczko, R.; Lopes, A. R.; Sanzovo, G. C.

    The wealth of available information on total visual magnitudes and broadband-V CCD observations of the exceptionally bright Comet C/1995 O1 (Hale-Bopp) proved to be an excellent opportunity to test the Semi-Empirical Method of Visual Magnitudes (de Almeida, Singh & Huebner, 1997) for very bright comets. The main objective is to extend the method to include total visual magnitude observations obtained with CCD detector and V filter in our analysis of total visual magnitudes and obtain a single light curve. We compare the CCD V-broadband careful observations of Liller (1997) by plotting then together with the total visual magnitude observations from experienced visual observers found in the International Comet Quarterly (ICQ) archive. We find a nice agreement despite of the fact that CCDs and V filter passbands detect systematically more coma than visual observers, since they have different responses to C2, which is the main emission from the coma, and consequently they should be used with larger apperture diameters. A data set of ˜400 CCD selected observations covering about the same 5 years time span of the ˜12,000 ICQ total visual magnitude observations were used in the analysis. A least-squares fit to the values yielded a relation for water production rates vs heliocentric distances for the pre- and post-perihelion phases and are converted into gas production rates (in g/s) released by the nucleus. The dimension of the nucleus as well as its effective active area is determined and compared to other works.

  20. UHV mirror mounts for photophysics beamline at Indus-I

    International Nuclear Information System (INIS)

    Meenakshi Raja Rao, P.; Bhattacharya, S.S.; Das, N.C.; Rajasekhar, B.N.; Roy, A.P.

    1995-01-01

    Photophysics beamline makes use of a combination of two toroidal mirrors and one meter Seya-Namioka Monochromator in its fore optics. The fore optics monochromatises and steers the synchrotron radiation source (SRS) beam from its tangent point to the sample situated at a distance of about five meters. Slit widths of the monochromator are of the order of 100μ and the sample size is one mm 2 . Hence it is essential to impart precision rotational and translational movements of the same order of magnitude to the mirrors with the use of appropriate mirror mounts. Since Indus-1 operates at a pressure -9 mbar, the mirror mounts should be UHV compatible and the movements should be actuated under UHV. The mirrors along with the mirror mounts are enclosed in UHV chambers. The mirror chambers have been fabricated at Centre for Advanced Technology (CAT) workshops and tested up to a pressure of 10 -9 mbar. The mirror mounts are designed, fabricated and leak checked (He leak rate -10 std cc/s) The precision movements are achieved with the help of bellow sealed shaft mechanism and adjustable screws provided with the kinematic mount of the mirror frame. The performance of the mirror mount was tested at atmospheric pressure by using a laser beam and found to be good. The minimum displacement of the laser beam at slit and sample positions is ∼ 70μ which is quite adequate for optical alignment. The performance of the mirror mount under UHV conditions is being evaluated. (author). 4 refs., 3 figs

  1. MiCPhot: A prime-focus multicolor CCD photometer on the 85-cm Telescope

    International Nuclear Information System (INIS)

    Zhou Aiying; Jiang Xiaojun; Wei Jianyan; Zhang Yanping

    2009-01-01

    We describe a new BV RI multicolor CCD photometric system situated at the prime focus of the 85-cm telescope at the Xinglong Station of NAOC. Atmospheric extinction effects, photometric accuracy and color calibration dependence of the system are investigated. Additional attention was paid to giving observers guidance in estimating throughput, detection limit, signal-to-noise ratio and exposure time. (invited reviews)

  2. A CCD camera probe for a superconducting cyclotron

    International Nuclear Information System (INIS)

    Marti, F.; Blue, R.; Kuchar, J.; Nolen, J.A.; Sherrill, B.; Yurkon, J.

    1991-01-01

    The traditional internal beam probes in cyclotrons have consisted of a differential element, a wire or thin strip, and a main probe with several fingers to determine the vertical distribution of the beam. The resolution of these probes is limited, especially in the vertical direction. The authors have developed a probe for their K1200 superconducting cyclotron based on a CCD TV camera that works in a 6 T magnetic field. The camera looks at the beam spot on a scintillating screen. The TV image is processed by a frame grabber that digitizes and displays the image in pseudocolor in real time. This probe has much better resolution than traditional probes. They can see beams with total currents as low as 0.1 pA, with position resolution of about 0.05 mm

  3. A USB 2.0 computer interface for the UCO/Lick CCD cameras

    Science.gov (United States)

    Wei, Mingzhi; Stover, Richard J.

    2004-09-01

    The new UCO/Lick Observatory CCD camera uses a 200 MHz fiber optic cable to transmit image data and an RS232 serial line for low speed bidirectional command and control. Increasingly RS232 is a legacy interface supported on fewer computers. The fiber optic cable requires either a custom interface board that is plugged into the mainboard of the image acquisition computer to accept the fiber directly or an interface converter that translates the fiber data onto a widely used standard interface. We present here a simple USB 2.0 interface for the UCO/Lick camera. A single USB cable connects to the image acquisition computer and the camera's RS232 serial and fiber optic cables plug into the USB interface. Since most computers now support USB 2.0 the Lick interface makes it possible to use the camera on essentially any modern computer that has the supporting software. No hardware modifications or additions to the computer are needed. The necessary device driver software has been written for the Linux operating system which is now widely used at Lick Observatory. The complete data acquisition software for the Lick CCD camera is running on a variety of PC style computers as well as an HP laptop.

  4. Scan-free grazing emission XRF measurements in the laboratory using a CCD

    International Nuclear Information System (INIS)

    Szwedowski, Veronika; Baumann, Jonas; Mantouvalou, Ioanna; Bauer, Leona; Malzer, Wolfgang; Kanngiesser, Birgit

    2017-01-01

    The rapid development of new classes of nanomaterials calls for easy access methods in order to quantify properties essential for their functionality, e.g., interdiffusion of elements at interfaces, or elemental dopant, or depth profiles. Non-destructive methods, like X-ray fluorescence (XRF), are of special interest, for preserving materials and offering the possibility to incorporate the analysis in a production process. In-depth XRF methods for the characterization of nanomaterials are up until now limited to synchrotron radiation facilities. A novel scan-free grazing emission XRF (GEXRF) setup is presented utilizing conventional and low-cost hardware, acting as a transfer of a synchrotron method into the laboratory. A chromium target X-ray tube with a polycapillary lens is used as X-ray source and a conventional CCD as the 2D energy-dispersive detector. To confirm the feasibility of the described setup a nanometer-layered titanium-aluminium sample is measured. An energy-dispersive spectrum is obtained in single-photon-counting-mode from the CCD measurements and first GEXRF profiles generated. A semi-quantitative evaluation of this setup is implemented by comparing the measured results with simulations, allowing conclusions about the investigated samples' elemental, compositional, and structural layer-by-layer characteristics. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Clinical study for pancreatic fistula after distal pancreatectomy with mesh reinforcement

    Directory of Open Access Journals (Sweden)

    Akira Hayashibe

    2018-05-01

    Full Text Available Summary: Background: The purpose of this cohort study was to determine whether distal pancreatectomy with mesh reinforcement can reduce postoperative pancreatic fistula (POPF rates compared with bare stapler. Methods: In total, 51 patients underwent stapled distal pancreatectomy. Out of these, 22 patients (no mesh group underwent distal pancreatectomy with bare stapler and 29 patients (mesh group underwent distal pancreatectomy with mesh reinforced stapler. The risk factor for clinically relevant POPF (grades B and C after distal pancreatectomy was also evaluated. Results: Clinical characteristics were almost similar in both the groups. The days of the mean hospital stay and drainage tube insertion in the mesh group were significantly fewer than those in the no mesh group. The mean level of amylase in the discharge fluid in the mesh group was also significantly lower than that the in no mesh group. The rate of clinically relevant POPF (grades B and C in the mesh group was significantly lower than that in the no mesh group (p=0.016. Univariate analyses of risk factors for POPF (grades B and C revealed that only mesh reinforcement was associated with POPF (grades B and C. Moreover, on multivariate analyses of POPF risk factors with p value<0.2 in univariate analyses by logistic regression, mesh reinforcement was regarded as a significant factor for POPF(grades B and C. Conclusions: The distal pancreatectomy with mesh reinforced stapler was thought to be favorable for the prevention of clinically relevant POPF (grades B and C. Keywords: mesh reinforcement, pancreatic fistula, pancreatic surgery

  6. A FORTRAN realization of the block adjustment of CCD frames

    Science.gov (United States)

    Yu, Yong; Tang, Zhenghong; Li, Jinling; Zhao, Ming

    A FORTRAN version realization of the block adjustment (BA) of overlapping CCD frames is developed. The flowchart is introduced including (a) data collection, (b) preprocessing, and (c) BA and object positioning. The subroutines and their functions are also demonstrated. The program package is tested by simulated data with/without the application of white noises. It is also preliminarily applied to the reduction of optical positions of four extragalactic radio sources. The results show that because of the increase in the sky coverage and number of reference stars, the precision of deducted positions is improved compared with single plate adjustment.

  7. Análise de mapas de represas publicados na web usando imagens orbitais CCD/CBERS no estado de Minas Gerais Analysis of dams maps published on the web by using orbital CCD/CBERS images in Minas Gerais State, Brazil

    Directory of Open Access Journals (Sweden)

    Elizabeth Ferreira

    2010-02-01

    Full Text Available Neste trabalho, bancos de dados públicos e gratuitos disponíveis na World Wide Web (WEB foram utilizados para avaliar as áreas das superfícies dos espelhos d'água das represas de Furnas e do Funil, no Estado de Minas Gerais. O objetivo foi comparar as informações obtidas nos bancos da WEB com os valores das áreas calculadas a partir de imagens do sensor CCD a bordo dos satélites CBERS2 e CBERS2B. A área da represa de Furnas obtida a partir das imagens CCD/CBERS2B, ano 2008, foi de 1.138 km², mas nos bancos de dados consultados esta área estava entre 1.182 e 1.503 km². A represa do Funil, construída em 2003, com superfície de espelho d'água de 29,37 km² e uma ilha com área de 1,93 km² não aparecem nos bancos Atlas, Geominas, IGAM e IBGE. Os resultados mostraram algumas discrepâncias nos bancos de dados publicados na WEB, tais como diferenças em áreas e supressão ou extrapolação de limites do espelho d'água. Concluiu-se que, até o momento, os responsáveis por algumas publicações de bancos de dados no Estado de Minas Gerais não tiveram rigor suficiente com as atualizações. As imagens CCD/CBERS, que também são dados públicos disponíveis na WEB, mostraram ser produtos adequados para verificar, atualizar e melhorar as informações publicadas.In this work some public databases from the World Wide Web (WEB were used to find the area of the Furnas and Funil Dams in Minas Gerais State. The purpose of this work was to compare the WEB public databases values and the real values obtained from the CCD camera images on board CBERS2 and CBERS2B satellites. The Furnas Dam area obtained from CCD/ CBERS2B images, in 2008, was 1.138 km², but in the consulted databases this area ranged from 1.182 to 1.503 km². The dam of the Funil, built in 2003, with a water surface of 29.37 km² and an island with 1.93 km² area, did not appear in Atlas, Geominas, IGAM and IBGE databases. The results revealed some problems in the WEB public

  8. Cost-effectiveness of laparoscopic versus open distal pancreatectomy for pancreatic cancer

    NARCIS (Netherlands)

    Gurusamy, K.S.; Riviere, D.M.; Laarhoven, C.J.H.M. van; Besselink, M.; Abu-Hilal, M.; Davidson, B.R.; Morris, S.

    2017-01-01

    BACKGROUND: A recent Cochrane review compared laparoscopic versus open distal pancreatectomy for people with for cancers of the body and tail of the pancreas and found that laparoscopic distal pancreatectomy may reduce the length of hospital stay. We compared the cost-effectiveness of laparoscopic

  9. Intersphincteric Resection and Coloanal Anastomosis in Treatment of Distal Rectal Cancer

    Directory of Open Access Journals (Sweden)

    Gokhan Cipe

    2012-01-01

    Full Text Available In the treatment of distal rectal cancer, abdominoperineal resection is traditionally performed. However, the recognition of shorter safe distal resection line, intersphincteric resection technique has given a chance of sphincter-saving surgery for patients with distal rectal cancer during last two decades and still is being performed as an alternative choice of abdominoperineal resection. The first aim of this study is to assess the morbidity, mortality, oncological, and functional outcomes of intersphincteric resection. The second aim is to compare outcomes of patients who underwent intersphincteric resection with the outcomes of patients who underwent abdominoperineal resection.

  10. Valgusdeformitet i anklen som følge af distal fibula-epifysefraktur

    DEFF Research Database (Denmark)

    Al-Aubaidi, Zaid

    2011-01-01

    Ankle fracture with involvement of the growth plate is the second most common paediatric fracture after the distal radius. The most common fracture type according to Salter Harris (SH) is type II of the distal tibia combined with green stick of the fibula. Isolated fracture of the distal fibular...... growth plate is not common and as a rule it does not give any growth arrest. We describe a case of isolated fibular fracture SH type II in a ten year-old girl which ended with symptomatic valgus deformity of the ankle. The patient was operated with good results....

  11. Epidemiology of distal forearm fractures in Oslo, Norway.

    Science.gov (United States)

    Lofthus, C M; Frihagen, F; Meyer, H E; Nordsletten, L; Melhuus, K; Falch, J A

    2008-06-01

    The population of Oslo has the highest incidence of hip fracture reported. The present study shows that the overall incidence of distal forearm fractures in Oslo is higher than in other countries and has not changed significantly when comparing the incidence of 1998/99 with 1979. The population of Oslo has the highest incidence of hip fracture reported. The present study reports the incidence of distal forearm fracture in Oslo and the fracture rates of immigrants. Patients aged > or = 20 years resident in Oslo sustaining a distal forearm fracture in a one-year period in 1998/99 were identified using electronic diagnosis registers, patient protocols, and/or X-ray registers of the clinics in Oslo. Medical records were obtained and the diagnosis verified. The age- and sex-specific incidence rates were calculated and compared with those for 1979. Data on immigrant category and country of origin of the patients were obtained. The age-adjusted fracture rates per 10,000 for the age group > or = 50 years were 109.8 and 25.4 in 1998/99 compared with 108.3 and 23.5 in 1979 for women and men, respectively (n.s.). The relative risk of fracture in Asians was 0.72 (95% CI 0.53-1.00) compared with ethnic Norwegians. The overall incidence of distal forearm fractures in Oslo is higher than in other countries and has not changed significantly when comparing the incidence of 1998/99 with 1979. Furthermore, the present data suggest that Asian immigrants in Oslo have a slightly lower fracture risk than ethnic Norwegians.

  12. Autosomal dominant distal myopathy: Linkage to chromosome 14

    Energy Technology Data Exchange (ETDEWEB)

    Laing, N.G.; Laing, B.A.; Wilton, S.D.; Dorosz, S.; Mastaglia, F.L.; Kakulas, B.A. [Australian Neuromuscular Research Institute, Perth (Australia); Robbins, P.; Meredith, C.; Honeyman, K.; Kozman, H.

    1995-02-01

    We have studied a family segregating a form of autosomal dominant distal myopathy (MIM 160500) and containing nine living affected individuals. The myopathy in this family is closest in clinical phenotype to that first described by Gowers in 1902. A search for linkage was conducted using microsatellite, VNTR, and RFLP markers. In total, 92 markers on all 22 autosomes were run. Positive linkage was obtained with 14 of 15 markers tested on chromosome 14, with little indication of linkage elsewhere in the genome. Maximum two-point LOD scores of 2.60 at recombination fraction .00 were obtained for the markers MYH7 and D14S64 - the family structure precludes a two-point LOD score {ge} 3. Recombinations with D14S72 and D14S49 indicate that this distal myopathy locus, MPD1, should lie between these markers. A multipoint analysis assuming 100% penetrance and using the markers D14S72, D14S50, MYH7, D14S64, D14S54, and D14S49 gave a LOD score of exactly 3 at MYH7. Analysis at a penetrance of 80% gave a LOD score of 2.8 at this marker. This probable localization of a gene for distal myopathy, MPD1, on chromosome 14 should allow other investigators studying distal myopathy families to test this region for linkage in other types of the disease, to confirm linkage or to demonstrate the likely genetic heterogeneity. 24 refs., 3 figs., 1 tab.

  13. Distal Oblique Bundle Reinforcement for Treatment of DRUJ Instability.

    Science.gov (United States)

    Brink, Peter R G; Hannemann, Pascal F W

    2015-08-01

    Background Chronic, dynamic bidirectional instability in the distal radioulnar joint (DRUJ) is diagnosed clinically, based on the patient's complaints and the finding of abnormal laxity in the vicinity of the distal ulna. In cases where malunion is ruled out or treated and there are no signs of osteoarthritis, stabilization of the DRUJ may offer relief. To this end, several different techniques have been investigated over the past 90 years. Materials and Methods In this article we outline the procedure for a new technique using a tendon graft to reinforce the distal edge of the interosseous membrane. Description of Technique A percutaneous technique is used to harvest the palmaris longus tendon and to create a tunnel, just proximal to the sigmoid notch, through the ulna and radius in an oblique direction. By overdrilling the radial cortex, the knotted tendon can be pulled through the radius and ulna and the knot blocked at the second radial cortex, creating a strong connection between the radius and ulna at the site of the distal oblique bundle (DOB). The tendon is fixed in the ulna with a small interference screw in full supination, preventing subluxation of the ulna out of the sigmoid notch during rotation. Results Fourteen patients were treated with this novel technique between 2011 and October 2013. The QuickDASH score at 25 months postoperatively (range 16-38 months) showed an improvement of 32 points. Similarly, an improvement of 33 points (67-34 months) was found on the PRWHE. Only one recurrence of chronic, dynamic bidirectional instability in the DRUJ was observed. Conclusion This simple percutaneous tenodesis technique between radius and ulna at the position of the distal edge of the interosseous membrane shows promise in terms of both restoring stability and relieving complaints related to chronic subluxation in the DRUJ.

  14. Traumatisk distal humerus-epifysiolyse hos nyfødt

    DEFF Research Database (Denmark)

    Al-Aubaidi, Zaid; Nielsen, Keld Daubjerg

    2010-01-01

    Traumatic distal humerus epiphysiolysis (TDHE) is a rare injury in infants with an incidence of about 1:35,000 births. It is primarily a birth injury, but it is also seen in cases of battered child syndrome. Because of its rare occurrence and the diagnostic difficulties, the lesion may be overloo......Traumatic distal humerus epiphysiolysis (TDHE) is a rare injury in infants with an incidence of about 1:35,000 births. It is primarily a birth injury, but it is also seen in cases of battered child syndrome. Because of its rare occurrence and the diagnostic difficulties, the lesion may...

  15. Hall Current Plasma Source Having a Center-Mounted or a Surface-Mounted Cathode

    Science.gov (United States)

    Martinez, Rafael A. (Inventor); Williams, John D. (Inventor); Moritz, Jr., Joel A. (Inventor); Farnell, Casey C. (Inventor)

    2018-01-01

    A miniature Hall current plasma source apparatus having magnetic shielding of the walls from ionized plasma, an integrated discharge channel and gas distributor, an instant-start hollow cathode mounted to the plasma source, and an externally mounted keeper, is described. The apparatus offers advantages over other Hall current plasma sources having similar power levels, including: lower mass, longer lifetime, lower part count including fewer power supplies, and the ability to be continuously adjustable to lower average power levels using pulsed operation and adjustment of the pulse duty cycle. The Hall current plasma source can provide propulsion for small spacecraft that either do not have sufficient power to accommodate a propulsion system or do not have available volume to incorporate the larger propulsion systems currently available. The present low-power Hall current plasma source can be used to provide energetic ions to assist the deposition of thin films in plasma processing applications.

  16. Galvanic coupling effects for module-mounting elements of ground-mounted photovoltaic power station

    Directory of Open Access Journals (Sweden)

    Pierozynski Boguslaw

    2017-12-01

    Full Text Available This communication reports on the concerns associated with possible generation of galvanic coupling effects for construction materials that are used to manufacture mounting assemblies for ground-mounted photovoltaic (PV power stations. For this purpose, six macro-corrosion galvanic cells were assembled, including: hot-dip Zn/Magnelis®-coated steel/Al and stainless steel (SS/Al cells. Corrosion experiments involved continuous, ca. three-month exposure of these couplings in 3 wt.% NaCl solution, conducted at room temperature for a stable pH value of around 8. All corrosion cells were subjected to regular assessment of galvanic current-density and potential parameters, where special consideration was given to compare the corrosion behaviour of Zn-coated steel samples with that of Magnelis®-coated electrodes. Characterization of surface condition and elemental composition for examined materials was carried-out by means of SEM and EDX spectroscopy techniques.

  17. Miyoshi-type distal muscular dystrophy. Clinical spectrum in 24 Dutch patients

    NARCIS (Netherlands)

    Linssen, W. H.; Notermans, N. C.; van der Graaf, Y.; Wokke, J. H.; van Doorn, P. A.; Höweler, C. J.; Busch, H. F.; de Jager, A. E.; de Visser, M.

    1997-01-01

    Miyoshi-type distal muscular dystrophy has now been found to be more frequent outside Japan than was previously thought. We studied 24 Dutch patients with Miyoshi-type distal muscular dystrophy and focused on its clinical expression and natural history, muscle CT-scans and muscle biopsy findings.

  18. Miyoshi-type distal muscular dystrophy. Clinical spectrum in 24 Dutch patients

    NARCIS (Netherlands)

    W.H.J.P. Linssen (Wim); N.C. Notermans (Nicolette); Y. van der Graaf (Yolanda); J.H.J. Wokke (John); P.A. van Doorn (Pieter); C.J. Höweler (Chris); H.F.M. Busch (Herman); A.E.J. de Jager (Aeiko); M. de Visser (Marianne)

    1997-01-01

    textabstractMiyoshi-type distal muscular dystrophy has now been found to be more frequent outside Japan than was previously thought. We studied 24 Dutch patients with Miyoshi-type distal muscular dystrophy and focused on its clinical expression and natural history muscle CT-scans and muscle biopsy

  19. Miyoshi-type distal muscular dystrophy - Clinical spectrum in 24 Dutch patients

    NARCIS (Netherlands)

    Linssen, WHJP; Notermans, NC; VanderGraaf, Y; Wokke, JHJ; VanDoorn, PA; Howeler, CJ; Busch, HFM; DeJager, AEJ; DeVisser, M

    1997-01-01

    Miyoshi-type distal muscular dystrophy has now been found to be more frequent outside Japan than was previously thought. We studied 24 Dutch patients with Miyoshi-type distal muscular dystrophy and focused on its clinical expression and natural history, muscle CT-scans and muscle biopsy findings.

  20. HIV Distal Neuropathic Pain Is Associated with Smaller Ventral Posterior Cingulate Cortex.

    Science.gov (United States)

    Keltner, John R; Connolly, Colm G; Vaida, Florin; Jenkinson, Mark; Fennema-Notestine, Christine; Archibald, Sarah; Akkari, Cherine; Schlein, Alexandra; Lee, Jisu; Wang, Dongzhe; Kim, Sung; Li, Han; Rennels, Austin; Miller, David J; Kesidis, George; Franklin, Donald R; Sanders, Chelsea; Corkran, Stephanie; Grant, Igor; Brown, Gregory G; Atkinson, J Hampton; Ellis, Ronald J

    2017-03-01

    . Despite modern antiretroviral therapy, HIV-associated neuropathy is one of the most prevalent, disabling and treatment-resistant complications of HIV disease. The presence and intensity of distal neuropathic pain is not fully explained by the degree of peripheral nerve damage. A better understanding of brain structure in HIV distal neuropathic pain may help explain why some patients with HIV neuropathy report pain while the majority does not. Previously, we reported that more intense distal neuropathic pain was associated with smaller total cerebral cortical gray matter volumes. The objective of this study was to determine which parts of the cortex are smaller. . HIV positive individuals with and without distal neuropathic pain enrolled in the multisite (N = 233) CNS HIV Antiretroviral Treatment Effects (CHARTER) study underwent structural brain magnetic resonance imaging. Voxel-based morphometry was used to investigate regional brain volumes in these structural brain images. . Left ventral posterior cingulate cortex was smaller for HIV positive individuals with versus without distal neuropathic pain (peak P  = 0.017; peak t = 5.15; MNI coordinates x = -6, y = -54, z = 20). Regional brain volumes within cortical gray matter structures typically associated with pain processing were also smaller for HIV positive individuals having higher intensity ratings of distal neuropathic pain. . The posterior cingulate is thought to be involved in inhibiting the perception of painful stimuli. Mechanistically a smaller posterior cingulate cortex structure may be related to reduced anti-nociception contributing to increased distal neuropathic pain. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  1. The alpine flora of Mount Wilhelm (New Guinea)

    NARCIS (Netherlands)

    Hoogland, R.D.

    1958-01-01

    The flora of the higher mountains of New Guinea has been the object of several extensive collecting trips in the past forty years. Until quite recently, however, a serious gap in our knowledge was the very scanty information available from the area between Mount Wilhelmina in the West and Mount

  2. Classification of Distal Fingertip Amputation Based on the Arterial System for Replantation

    OpenAIRE

    Park, Hyun Chul; Bahar-Moni, Ahmed Suparno; Cho, Sang Hyun; Kim, Sang Soo; Park, Hyun Sik; Ahn, Sang Cheon

    2012-01-01

    During replantation of distal fingertip amputation, identification of the artery is the most important but time consuming procedure. Depending on the damaged arterial structure, we classified distal fingertip amputations into 4 zones, on the basis of three dimensional concept. Zone 1 injury was defined as damage to the proximal central pulp artery; zone 2 injury, damage to the branch of the central pulp artery; zone 3 injury, damage to the distal central pulp artery; and zone 4 injury, no inj...

  3. Optimization of Classical Hydraulic Engine Mounts Based on RMS Method

    Directory of Open Access Journals (Sweden)

    J. Christopherson

    2005-01-01

    Full Text Available Based on RMS averaging of the frequency response functions of the absolute acceleration and relative displacement transmissibility, optimal parameters describing the hydraulic engine mount are determined to explain the internal mount geometry. More specifically, it is shown that a line of minima exists to define a relationship between the absolute acceleration and relative displacement transmissibility of a sprung mass using a hydraulic mount as a means of suspension. This line of minima is used to determine several optimal systems developed on the basis of different clearance requirements, hence different relative displacement requirements, and compare them by means of their respective acceleration and displacement transmissibility functions. In addition, the transient response of the mount to a step input is also investigated to show the effects of the optimization upon the time domain response of the hydraulic mount.

  4. A new CCD-camera neutron radiography detector at the Atominstitute of the Austrian Universities

    International Nuclear Information System (INIS)

    Koerner, S.; Boeck, H.; Rauch, H.; Lehmann, E.

    1999-01-01

    Neutron radiography provides a very efficient tool for non-destructive testing as well as for many applications in fundamental research. A neutron beam penetrating a specimen is attenuated by the sample material and detected by a two dimensional imaging device. The image contains information about materials and structure inside the sample because neutrons are attenuated according to the basic law of radiation attenuation. At the Atominstitute of the Austrian Universities neutron radiographic examinations have been carried out for more than 35 years, mainly with detectors consisting of X-ray films and a Gd- converter enclosed in a vacuum cassette. Presently a neutron tomography set-up is under development. For high quality 3D image reconstruction, about 200 digitized neutron transmission images from different angles of the object are necessary. Therefore the first step was the design of an adequate electronic neutron radiography imaging device. The requirements for a detector suitable for neutron tomography are: exact and reproducible positioning, easy handling, high spatial resolution and dynamic range, high efficiency and a good linearity. The key components of the detector system selected on the basis of the requirements consist of a neutron sensitive scintillator screen, a cooled slow scan CCD camera and a mirror to reflect the light emitted by the scintillator to the CCD camera. The whole assembly is placed in a light tight enclosure. In this paper the strategy of the selection of the individual detector components is described. Comparisons on the influence of the use of different components on the properties of the whole position sensitive imaging device are demonstrated. Finally the new CCD camera neutron radiography detector of the Atominstitute is presented and first results of test measurements performed at the neutron radiography facility NEUTRA at the continuous spallation source SINQ at Paul Scherrer Institute are shown.(author)

  5. Insights into the formation of carlactone from in-depth analysis of the CCD8-catalyzed reactions

    KAUST Repository

    Bruno, Mark; Vermathen, Martina; Alder, Adrian; Wü st, Florian; Schaub, Patrick; van der Steen, Rob; Beyer, Peter; Ghisla, Sandro; Al-Babili, Salim

    2017-01-01

    Strigolactones (SLs) are a new class of phytohormones synthesized from carotenoids via carlactone. The complex structure of carlactone is not easily deducible from its precursor, a cis-configured β-carotene cleavage product, and is thus formed via a poorly understood series of reactions and molecular rearrangements, all catalyzed by only one enzyme, the carotenoid cleavage dioxygenase 8 (CCD8). Moreover, the reactions leading to carlactone are expected to form a second, yet unidentified product. In this study, we used (13) C and (18) O-labelling to shed light on the reactions catalyzed by CCD8. The characterization of the resulting carlactone by LC-MS and NMR, and the identification of the assumed, less accessible second product allowed us to formulate a minimal reaction mechanism for carlactone generation. This article is protected by copyright. All rights reserved.

  6. Insights into the formation of carlactone from in-depth analysis of the CCD8-catalyzed reactions

    KAUST Repository

    Bruno, Mark

    2017-02-10

    Strigolactones (SLs) are a new class of phytohormones synthesized from carotenoids via carlactone. The complex structure of carlactone is not easily deducible from its precursor, a cis-configured β-carotene cleavage product, and is thus formed via a poorly understood series of reactions and molecular rearrangements, all catalyzed by only one enzyme, the carotenoid cleavage dioxygenase 8 (CCD8). Moreover, the reactions leading to carlactone are expected to form a second, yet unidentified product. In this study, we used (13) C and (18) O-labelling to shed light on the reactions catalyzed by CCD8. The characterization of the resulting carlactone by LC-MS and NMR, and the identification of the assumed, less accessible second product allowed us to formulate a minimal reaction mechanism for carlactone generation. This article is protected by copyright. All rights reserved.

  7. Mirror boxes and mirror mounts for photophysics beamline

    International Nuclear Information System (INIS)

    Raja Rao, P.M.; Raja Sekhar, B.N.; Das, N.C.; Khan, H.A.; Bhattacharya, S.S.; Roy, A.P.

    1996-01-01

    Photophysics beamline makes use of one metre Seya-Namioka monochromator and two toroidal mirrors in its fore optics. The first toroidal mirror (pre mirror) focuses light originating from the tangent point of the storage ring onto the entrance slit of the monochromator and second toroidal mirror (post mirror) collects light from the exit slit of the monochromator and focuses light onto the sample placed at a distance of about one metre away from the 2nd mirror. To steer light through monochromator and to focus it on the sample of 1mm x 1mm size require precision rotational and translational motion of the mirrors and this has been achieved with the help of precision mirror mounts. Since Indus-1 operates at pressures less than 10 -9 m.bar, the mirror mounts should be manipulated under similar ultra high vacuum conditions. Considering these requirements, two mirror boxes and two mirror mounts have been designed and fabricated. The coarse movements to the mirrors are imparted from outside the mirror chamber with the help of x-y tables and precision movements to the mirrors are achieved with the help of mirror mounts. The UHV compatibility and performance of the mirror mounts connected to mirror boxes under ultra high vacuum condition is evaluated. The details of the design, fabrication and performance evaluation are discussed in this report. 5 refs., 9 figs., 1 tab

  8. Distal radioulnar joint: functional anatomy, including pathomechanics.

    Science.gov (United States)

    Haugstvedt, J R; Langer, M F; Berger, R A

    2017-05-01

    The distal radioulnar joint allows the human to rotate the forearm to place the hand in a desired position to perform different tasks, without interfering with the grasping function of the hand. The ulna is the stable part of the forearm around which the radius rotates; the stability of the distal radioulnar joint is provided by the interaction between ligaments, muscles and bones. The stabilizing structures are the triangular fibrocartilage complex, the ulnocarpal ligament complex, the extensor carpi ulnaris tendon and tendon sheath, the pronator quadratus, the interosseous membrane and ligament, the bone itself and the joint capsule. The purpose of this review article is to present and illustrate the current understanding of the functional anatomy and pathomechanics of this joint.

  9. Technical aspects and preliminary results of the CCD camera diagnostics on Extrap T2

    International Nuclear Information System (INIS)

    Cecconello, M.; Brzozowski, J.

    1999-01-01

    During the last months of Extrap T2 operations an imaging acquisition system, based on charge-coupled devices (CCD) cameras, has been operated. CCD cameras are a standard diagnostic used in many fusion experiments: i) to obtain a direct insight of the plasma behaviour during the pulse, of the evolution of plasma-wall interactions and, eventually, of locked modes, ii) to measure local quantities such as the wall temperature and the impurity influxes, iii) to study the hydrogen recycling behaviour and iv) to estimate the poloidal and toroidal mode numbers. One of the aims of our imaging campaign was to check the utility of such diagnostic for T2. The purpose of this report is to describe the technical aspects involved in the use of such diagnostic and to briefly describe the results obtained. In this view, this report aims to be a guide to the development of a dedicated image acquisition system for Extrap T2, after the planned rebuild, by stressing the problems and limitations encountered during this campaign

  10. Complete mucosal healing of distal lesions induced by twice-daily budesonide 2-mg foam promoted clinical remission of mild-to-moderate ulcerative colitis with distal active inflammation: double-blind, randomized study.

    Science.gov (United States)

    Naganuma, Makoto; Aoyama, Nobuo; Tada, Tomohiro; Kobayashi, Kiyonori; Hirai, Fumihito; Watanabe, Kenji; Watanabe, Mamoru; Hibi, Toshifumi

    2018-04-01

    Budesonide foam is used for the topical treatment of distal ulcerative colitis. This phase III study was performed to confirm mucosal healing and other therapeutic effects of twice-daily budesonide 2-mg foam in patients with mild-to-moderate ulcerative colitis including left-sided colitis and pancolitis. This was a multicenter, randomized, placebo-controlled, double-blind trial. A total of 126 patients with mild-to-moderate ulcerative colitis with active inflammation in the distal colon were randomized to two groups receiving twice-daily budesonide 2 mg/25 ml foam or placebo foam. The primary endpoint was the percentage of complete mucosal healing of distal lesions (endoscopic subscore of 0) at week 6. Some patients continued the treatment through week 12. Drug efficacy and safety were evaluated. The percentages of both complete mucosal healing of distal lesions and clinical remission were significantly improved in the budesonide as compared with the placebo group (p = 0.0003 and p = 0.0035). Subgroup analysis showed similar efficacy of budesonide foam for complete mucosal healing of distal lesions and clinical remission regardless of disease type. The clinical remission percentage tended to be higher in patients achieving complete mucosal healing of distal lesions than in other patients. There were no safety concerns with budesonide foam. This study confirmed for the first time complete mucosal healing with twice-daily budesonide 2-mg foam in mild-to-moderate ulcerative colitis with distal active inflammation. The results also indicated that complete mucosal healing of distal lesions by budesonide foam promotes clinical remission of ulcerative colitis. Clinical trial registration no.: Japic CTI-142704.

  11. Efficiency and safety of percuSurge distal protection device in acute ...

    African Journals Online (AJOL)

    user

    2011-04-25

    Apr 25, 2011 ... myocardial infarction. The long-term effects of the distal protection device are still in controversy. The enhanced myocardial efficacy and recovery by aspiration of liberated debris (EMERALD) trial failed to show the effectiveness of the distal protection device in patients with AMI (Yamada and Topol, 2000).

  12. Ball mounting fixture for a roundness gage

    Science.gov (United States)

    Gauler, Allen L.; Pasieka, Donald F.

    1983-01-01

    A ball mounting fixture for a roundness gage is disclosed. The fixture includes a pair of chuck assemblies oriented substantially transversely with respect to one another and mounted on a common base. Each chuck assembly preferably includes a rotary stage and a wobble plate affixed thereto. A ball chuck affixed to each wobble plate is operable to selectively support a ball to be measured for roundness, with the wobble plate permitting the ball chuck to be tilted to center the ball on the axis of rotation of the rotary stage. In a preferred embodiment, each chuck assembly includes a vacuum chuck operable to selectively support the ball to be measured for roundness. The mounting fixture enables a series of roundness measurements to be taken with a conventional rotating gagehead roundness instrument, which measurements can be utilized to determine the sphericity of the ball.

  13. Tension pneumocephalus: Mount Fuji sign

    Directory of Open Access Journals (Sweden)

    Pulastya Sanyal

    2015-01-01

    Full Text Available A 13-year-old male was operated for a space occupying lesion in the brain. A noncontrast computed tomography scan done in the late postoperative period showed massive subdural air collection causing compression of bilateral frontal lobes with widening of interhemispheric fissure and the frontal lobes acquiring a peak like configuration - causing tension pneumocephalus-"Mount Fuji sign." Tension pneumocephalus occurs when air enters the extradural or intradural spaces in sufficient volume to exert a mass or pressure effect on the brain, leading to brain herniation. Tension pneumocephalus is a surgical emergency, which needs immediate intervention in the form of decompression of the cranial cavity by a burr hole or needle aspiration. The Mount Fuji sign differentiates tension pneumocephalus from pneumocephalus.

  14. Tratamiento quirúrgico de la falange distal bífida por traumatismo de mano en la infancia Tratamento cirurgico de falange distal bifida pós traumatismo de mão na infância Surgical treatment of distal bifid phalanx post of hand trauma in childhood

    Directory of Open Access Journals (Sweden)

    F. Passos da Rocha

    2011-03-01

    Full Text Available La extremidad distal de los dedos es la parte de la mano que más frecuentemente se lesiona. Las principales complicaciones que pueden derivar de ese tipo de lesiones traumáticas incluyen: infecciones, retracciones de la piel, deformidades óseas y amputaciones. El presente artículo tiene como objetivo presentar el tratamiento quirúrgico seguido en un pacientes de 16 años que sufrió traumatismo sobre la falange distal del segundo dedo de la mano derecha a los 2 años de edad, a consecuencia del cual se produjo deformidad ósea y falange bífida asociada a retracción de la piel en el punto de la lesión.A extremidade distal dos dedos é a parte da mão mais freqüentemente lesionada. As principais complicações que podem ocorrer como conseqüências dessas lesões traumáticas incluem: as infecções, as retrações da pele, as deformidades ósseas e as amputações. O presente trabalho tem como objetivo relatar o tratamento cirúrgico de um paciente de 16 anos que sofreu um trauma na falange distal do segundo dedo da mão direita aos dois anos de idade, resultando em deformidade óssea e falange distal bífida associada a retração de pele no local onde ocorreu a lesão.The distal extremity of the fingers of the hand is the most frequently injured. The main complications that can occur as a result of these traumatic injuries include: infections, retraction of the skin, bone deformities and amputations. This article aims to report the surgical treatment of a 16 years old patient who suffered a trauma in the distal phalanx of the second finger of right hand when he was 2 years old, resulting in bone deformity and distal phalanx bifid associated with retraction of the skin at the site where the injury occurred.

  15. Taking Charge: Walter Sydney Adams and the Mount Wilson Observatory

    Science.gov (United States)

    Brashear, R.

    2004-12-01

    The growing preeminence of American observational astronomy in the first half of the 20th century is a well-known story and much credit is given to George Ellery Hale and his skill as an observatory-building entrepreneur. But a key figure who has yet to be discussed in great detail is Walter Sydney Adams (1876-1956), Hale's Assistant Director at Mount Wilson Observatory. Due to Hale's illnesses, Adams was Acting Director for much of Hale's tenure, and he became the second Director of Mount Wilson from 1923 to 1946. Behind his New England reserve Adams was instrumental in the growth of Mount Wilson and thus American astronomy in general. Adams was hand-picked by Hale to take charge of stellar spectroscopy work at Yerkes and Mount Wilson and the younger astronomer showed tremendous loyalty to Hale and Hale's vision throughout his career. As Adams assumed the leadership role at Mount Wilson he concentrated on making the observatory a place where researchers worked with great freedom but maintain a high level of cooperation. This paper will concentrate on Adams's early years and look at his growing relationship with Hale and how he came to be the central figure in the early history of Mount Wilson as both a solar and stellar observatory. His education, his years at Dartmouth and Yerkes (including his unfortunate encounter with epsilon Leonis), and his formative years on Mount Wilson are all important in learning how he shaped the direction of Mount Wilson and the development of American astronomy in the first half of the 20th century. This latter history cannot be complete until we bring Adams into better focus.

  16. Single-Pulse Dual-Energy Mammography Using a Binary Screen Coupled to Dual CCD Cameras

    Science.gov (United States)

    1999-08-01

    Fossum, "Active pixel sensors—Are CCD’s Dinosaurs ?," Proc. SPIE 1900, 2-14 (1993). "S. Mendis, S. E. Kemeny, R. Gee, B. Pain, and E. R. Fossum, "Progress...Clin Oncol 13:1470-1477, 1995 12. Wahl RL, Zasadny K, Helvie M, et al: Metabolic monitoring of breast cancer chemohormonotherapy using posi- tron

  17. Comparison of a CCD and an APS for soft x-ray diffraction

    OpenAIRE

    Stewart, G.; Bates, R.; Blue, A.; Clark, A.; Dhesi, S.S.; Maneuski, D.; Marchal, J.; Steadman, P.; Tartoni, N.; Turchetta, R.

    2011-01-01

    We compare a new CMOS Active Pixel Sensor (APS) to a Princeton Instruments PIXIS-XO: 2048B Charge Coupled Device (CCD) with soft X-rays tested in a synchrotron beam line at the Diamond Light Source (DLS). Despite CCDs being established in the field of scientific imaging, APS are an innovative technology that offers advantages over CCDs. These include faster readout, higher operational temperature, in-pixel electronics for advanced image processing and reduced manufacturing cost.\\ud \\ud The AP...

  18. Distal vein patch as a form of autologus modification for infragenicular prosthetic bypass.

    Science.gov (United States)

    Totic, Dragan; Rustempasic, Nedzad; Djedovic, Muhamed; Solakovic, Sid; Vukas, Haris; Aslani, Ilijas; Krvavac, Alma; Rudalija, Dzejra; Ahmetasevic, Alen

    2013-01-01

    Preferred graft for infragenicular bypass is autologus vein. The problem is when there is not available autologus vein. Literature suggest that in these situations, prosthetic graft with some form of modification of distal anastomosis with autogenic tissue is valuable adjunctive. Frequently used modifications are Miller's cuff, Taylor's patch and St. Mary's boot. Recently, there are reports on "Distal vein patch" as a form of autologus modification which, due to its simplicity and patency rate, attracted attention. The aim of this study was to evaluate benefits of this novel modification by comparing its patencies with other autologus modification of distal anastomosis. Study was performed on 60 patients, diabetics, with critical limb ischemia (CLI). Patients were divided in two groups: Group with distal vein patch modification; and group with some other form modification - control group. Patients were followed at least 22 months. We examined patency of grafts by physical examination or using Color Doppler. For statistical purposes we used KIaplan Meier analysis and curve. Significance was determined by Mann-Whitney, Fisher's exact, Pearsons chi square or Student T test as appropriate. P value less than 0,05 was considered significant. Groups were fairly matched relative to demographics, risk factors, operative intervention and distal anastomosis site. There was not statistical difference in two year primary patency between distal vein patch and control group--50% vs 53% respectivly (X2 = 0,08; p = 0,773). Also, there was not statistically significant difference in extremity survival (77% vs 77%) and patient survival between groups (89% vs 93%; X2 = 2,458; p = 0,117). This study proved equivalent patencies of infragenicular prosthetic bypasses performed using distal vein patch technique as with any other modification of distal anastomosis.

  19. Management and treatment of distal ulcerative colitis

    Directory of Open Access Journals (Sweden)

    Andrea Calafiore

    2013-12-01

    Full Text Available Ulcerative colitis (UC is a chronic inflammatory condition that is confined to the colonic mucosa. Its main symptoms include diarrhea, rectal bleeding and abdominal pain. Approximately two-thirds of UC patients have disease confined distal to the splenic flexure, which can be treated effectively with topical therapy. This means the active drug can be delivered directly to the site of inflammation, limiting the systemic absorption and potential side effects. Topical treatment with aminosalicylates is the most effective approach in the treatment of these forms, provided that the formulation reaches the upper margin of the disease. Given this, the suppository formulation is the treatment of choice for proctitis and distal sigmoiditis. Thanks to their proximal spread, enemas, foams and gels represent the treatment of choice for proctosigmoiditis and for distal ulcerative colitis. Oral aminosalicylates are less effective than topical therapies in patients with active disease, while the combination of topical and oral treatment is more effective in patients refractory to topical or oral mono-therapy. Topically administered aminosalicylates play an important role in the maintenance of remission, but the long-term adhesion to therapy is poor. For this reason, the oral formulation is the first-line therapy in the maintenance of remission. Refractory patients can be treated with topical steroids or systemic steroids and TNF-alpha inhibitors in severe forms.

  20. Left ventricular contractile function after distal protection in primary percutaneous coronary intervention Results from the Drug Elution and Distal Protection in ST-Elevation Myocardial Infarction trial

    DEFF Research Database (Denmark)

    Kofoed, K F; Kelbæk, H; Thuesen, L

    2011-01-01

    Coronary intervention (PCI) may result in an increased infarct size. We evaluated the effect of distal protection during PCI for ST-segment elevation myocardial infarction (STEMI) on myocardial function.......Coronary intervention (PCI) may result in an increased infarct size. We evaluated the effect of distal protection during PCI for ST-segment elevation myocardial infarction (STEMI) on myocardial function....

  1. Fractures of the distal tibia treated with polyaxial locking plating.

    Science.gov (United States)

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2009-03-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial infections and evidence of delayed wound healing. Using the American Orthopaedic Foot and Ankle Society ankle score, the average functional score was 87.3 points (of 100 total possible points). Our results show the polyaxial locking plates, which offer more fixation versatility, may be a reasonable treatment option for distal tibia fractures with very short metaphyseal segments.

  2. A magneto-rheological fluid mount featuring squeeze mode: analysis and testing

    International Nuclear Information System (INIS)

    Chen, Peng; Bai, Xian-Xu; Qian, Li-Jun; Choi, Seung-Bok

    2016-01-01

    This paper presents a mathematical model for a new semi-active vehicle engine mount utilizing magneto-rheological (MR) fluids in squeeze mode (MR mount in short) and validates the model by comparing analysis results with experimental tests. The proposed MR mount is mainly comprised of a frame for installation, a main rubber, a squeeze plate and a bobbin for coil winding. When the magnetic fields on, MR effect occurs in the upper gap between the squeeze plate and the bobbin, and the dynamic stiffness can be controlled by tuning the applied currents. Employing Bingham model and flow properties between parallel plates of MR fluids, a mathematical model for the squeeze type of MR mount is formulated with consideration of the fluid inertia, MR effect and hysteresis property. The field-dependent dynamic stiffness of the MR mount is then analyzed using the established mathematical model. Subsequently, in order to validate the mathematical model, an appropriate size of MR mount is fabricated and tested. The field-dependent force and dynamic stiffness of the proposed MR mount are evaluated and compared between the model and experimental tests in both time and frequency domains to verify the model efficiency. In addition, it is shown that both the damping property and the stiffness property of the proposed MR mount can be simultaneously controlled. (paper)

  3. Vertebral artery origin stent placement with distal protection: technical and clinical results.

    Science.gov (United States)

    Qureshi, A I; Kirmani, J F; Harris-Lane, P; Divani, A A; Ahmed, S; Ebrihimi, A; Al Kawi, A; Janjua, N

    2006-05-01

    To report the feasibility, safety, and 1-month results of performing stent placement for vertebral origin stenosis with the use of a distal protection device. Distal protection devices have been shown to reduce the number of cerebral emboli and subsequent ischemic events when used as adjuncts to percutaneous carotid intervention; however, one case of the use of a distal protection device for vertebral artery has been reported in the literature. We retrospectively determined rates of technical success and 1-month stroke or death associated with stent placement by using distal protection (Filter EX; Boston Scientific, Natick, Mass) in patients with symptomatic vertebral artery origin stenosis. Technical success was defined as successful deployment of distal protection device and stent at target lesion followed by successful retrieval of the device and a final residual stenosis of less than 30%. Other outcomes ascertained included any stroke, death, and semiquantitative assessment of particulate material retained by the filter device. The mean age of the 12 treated patients was 68 years (range, 52-88 years) and the group included 9 men and 3 women. The mean percentage of vertebral artery origin stenosis was 71 +/- 6%. Femoral and radial approaches were used in 9 and 3 cases, respectively. Technical success was achieved in 11 of the 12 patients in whom distal protection device placement was attempted. Postprocedure residual stenosis was 5 +/- 4%. Eight devices held macroscopically visible embolic debris (large and small amounts in 3 and 5 devices, respectively). No stroke or death was observed in the 1-month follow-up. The present study demonstrates the feasibility of performing stent placement for vertebral artery origin stenosis by using a distal protection device. Further studies are required to determine the effectiveness of this approach for vertebral artery origin atherosclerosis.

  4. Solar rotation measurements at Mount Wilson. Pt. 2

    International Nuclear Information System (INIS)

    Labonte, B.J.; Howard, R.; Carnegie Institution of Washington, Pasadena

    1981-01-01

    Possible sources of systematic error in solar Doppler rotational velocities are examined. Scattered light is shown to affect the Mount Wilson solar rotation results, but this effect is not enough to bring the spectroscopic results in coincidence with the sunspot rotation. Interference fringes at the spectrograph focus at Mount Wilson have in two intervals affected the rotation results. It has been possible to correlate this error with temperature and thus correct for it. A misalignment between the entrance and exit slits is a possible source of error, but for the Mount Wilson slit configuration the amplitude of this effect is negligibly small. Rapid scanning of the solar image also produces no measurable effect. (orig.)

  5. Rapid mounting of adult Drosophila structures in Hoyer's medium.

    Science.gov (United States)

    Stern, David L; Sucena, Elio

    2012-01-01

    The Drosophila cuticle carries a rich array of morphological details. Thus, cuticle examination has had a central role in the history of genetics. This protocol describes a procedure for mounting adult cuticles in Hoyer's medium, a useful mountant for both larval and adult cuticles. The medium digests soft tissues rapidly, leaving the cuticle cleared for observation. In addition, samples can be transferred directly from water to Hoyer's medium. However, specimens mounted in Hoyer's medium degrade over time. For example, the fine denticles on the larval dorsum are best observed soon after mounting; they begin to fade after 1 week, and can disappear completely after several months. More robust features, such as the ventral denticle belts, will persist for a longer period of time. Because adults cannot profitably be mounted whole in Hoyer's medium, some dissection is necessary.

  6. Classification of distal fingertip amputation based on the arterial system for replantation.

    Science.gov (United States)

    Park, Hyun Chul; Bahar-Moni, Ahmed Suparno; Cho, Sang Hyun; Kim, Sang Soo; Park, Hyun Sik; Ahn, Sang Cheon

    2013-06-01

    During replantation of distal fingertip amputation, identification of the artery is the most important but time consuming procedure. Depending on the damaged arterial structure, we classified distal fingertip amputations into 4 zones, on the basis of three dimensional concept. Zone 1 injury was defined as damage to the proximal central pulp artery; zone 2 injury, damage to the branch of the central pulp artery; zone 3 injury, damage to the distal central pulp artery; and zone 4 injury, no injury to the central pulp artery, injury only to the lateral pulp artery. From April 2010 to June 2011, 27 patients were evaluated. Successful replantation was observed in 21 patients. Skin necrosis occurred in six patients. For distal fingertip amputation classification based on the damaged arterial system is an easy method to find out the appropriate artery which should be anastomosed during replantation.

  7. Robotic spleen-preserving distal pancreatectomy. A case report.

    Science.gov (United States)

    Vasilescu, C; Sgarbura, O; Tudor, S; Herlea, V; Popescu, I

    2009-01-01

    Distal pancreatectomy (DP) is the removal of the pancreatic tissue at the left side of the superior mesenteric vein and it is traditionally approached by an open or laparoscopic exposure. Preservation of the spleen is optional but appears to have a better immunological outcome. We present the case of a 53-year old patient with a 2.4/2.2 tumor located in the tail of the pancreas, with high tumour marker values for whom we decided to perform a robotic spleen-preserving distal pancreatectomy (RSPDP). The postoperative outcome was satisfactory. In conclusion, we recommend this type of approach for small pancreatic tail lesions.

  8. Modified distal shoe appliance--fabrication and clinical performance.

    Science.gov (United States)

    Gujjar, Kumar Raghav; Indushekar, K R; Amith, H V; Sharma, Shefali Li

    2012-01-01

    When the primary second molar is prematurely lost, mesial movement and migration of the permanent first molar often occurs. This is one of the most difficult problems of the developing dentition confronted by pediatric dentists. Use of a space maintainer that will guide the permanent first molar into its normal position is indicated. In cases with bilateral premature loss of primary molars, the conventional design of distal shoe poses a variety of problems and, therefore, necessitates a customized design for the eruption guidance of permanent first molars. The purpose of this case report is to discuss an innovative design of a distal shoe appliance, which was used with good clinical results.

  9. A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

    Directory of Open Access Journals (Sweden)

    Prakash Jayakumar

    2015-04-01

    Full Text Available Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking screw, which must also avoid the olecranon, coronoid, and radial fossae. We describe 3 patients (ages 27, 49, and 73 years with a bicolumnar fracture of the distal humerus where very short distal locking screws were used. Intra-articular screw placement was avoided but loss of fixation occurred in two patients and a third was treated with a prolonged period of immobilization. We postulate that fixed-angle screw trajectories may make it difficult for the surgeon to place screws of adequate length in this anatomically confined region, and may lead to insufficient distal fixation. Surgical tactics should include placement of as many screws as possible into the distal fragment, as long as possible, and that each screw pass through a plate without necessarily locking in.

  10. Mounting system for optical frequency reference cavities

    Science.gov (United States)

    Notcutt, Mark (Inventor); Hall, John L. (Inventor); Ma, Long-Sheng (Inventor)

    2008-01-01

    A technique for reducing the vibration sensitivity of laser-stabilizing optical reference cavities is based upon an improved design and mounting method for the cavity, wherein the cavity is mounted vertically. It is suspended at one plane, around the spacer cylinder, equidistant from the mirror ends of the cavity. The suspension element is a collar of an extremely low thermal expansion coefficient material, which surrounds the spacer cylinder and contacts it uniformly. Once the collar has been properly located, it is cemented in place so that the spacer cylinder is uniformly supported and does not have to be squeezed at all. The collar also includes a number of cavities partially bored into its lower flat surface, around the axial bore. These cavities are support points, into which mounting base pins will be inserted. Hence the collar is supported at a minimum of three points.

  11. Exploring Virtual Worlds With Head-Mounted Displays

    Science.gov (United States)

    Chung, James C.; Harris, Mark R.; Brooks, Frederick P.; Fuchs, Henry; Kelley, Michael T.; Hughes, John W.; Ouh-Young, Ming; Cheung, Clement; Holloway, Richard L.; Pique, Michael

    1989-09-01

    For nearly a decade the University of North Carolina at Chapel Hill has been conducting research in the use of simple head-mounted displays in "real-world" applications. Such units provide the user with non-holographic true three-dimensional information, since the kinetic depth effect, stereoscopy, and other visual cues combine to immerse the user in a "virtual world" which behaves like the real world in some respects. UNC's head-mounted display was built inexpensively from commercially available off-the-shelf components. Tracking of the the user's head position and orientation is performed by a Polhemus Navigation Sciences' 3SPACE* tracker. The host computer uses the tracking information to generate updated images corresponding to the user's new left eye and right eye views. The images are broadcast to two liquid crystal television screens (220x320 pixels) mounted on a horizontal shelf at the user's forehead. The user views these color screens through half-silvered mirrors, enabling the computer-generated image to be superimposed upon the user's real physical environment. The head-mounted display has been incorporated into existing molecular modeling and architectural applications being developed at UNC. In molecular structure studies, chemists are presented with a room-sized molecule with which they can interact in a manner more intuitive than that provided by conventional two-dimensional displays and dial boxes. Walking around and through the large molecule may provide quicker understanding of its structure, and such problems as drug-enzyme docking may be approached with greater insight. In architecture, the head-mounted display enables clients to better appreciate three-dimensional designs, which may be misinterpreted in their conventional two-dimensional form by untrained eyes. The addition of a treadmill to the system provides additional kinesthetic input into the understanding of building size and scale.

  12. Genetics Home Reference: distal arthrogryposis type 1

    Science.gov (United States)

    ... 1 is a disorder characterized by joint deformities (contractures) that restrict movement in the hands and feet. ... distal arthrogryposis type 1 . However, researchers speculate that contractures may be related to problems with muscle contraction ...

  13. Palladium catalyzed selective distal C-H olefination of biaryl systems.

    Science.gov (United States)

    Maity, Soham; Hoque, Ehtasimul; Dhawa, Uttam; Maiti, Debabrata

    2016-11-29

    Palladium catalyzed selective distal C-H activation with nitrile based templates has been of significant research interest in recent times. In this report, we disclose the distal C-H olefination of biphenyl systems with high regio- and stereo-selectivity and useful synthetic yields. The utility of this method has been demonstrated through its wide olefin scope, its operation at the gram scale and the easy removal/recovery of the directing group.

  14. Increased T2 signal intensity in the distal clavicle: incidence and clinical implications

    International Nuclear Information System (INIS)

    Fiorella, D.; Helms, C.A.; Speer, K.P.

    2000-01-01

    Objective. The objectives of the current study were (1) to quantify the incidence of increased T2 signal in the distal clavicle and (2) to assess the clinical significance of this finding in patients with chronic acromioclavicular (AC) joint pain.Design and patients. Eight patients (five male and three female, 15-41 years of age) with disabling shoulder pain localized to the AC joint and marked increased T2 signal in the distal clavicle are presented. These eight patients underwent MR examination over a 25 month period (August 1996 to September 1998). The dictated reports of all shoulder MR examinations conducted over this same time period were reviewed retrospectively for the presence of signal abnormality in the distal cla-vicle. Clinical data and, in five patients, findings at shoulder arthroscopy or open surgery, were correlated with the results of MR imaging. One patient underwent arthroscopy on both shoulders.Results. The selected eight patients each presented clinically with disabling shoulder pain localized to the AC joint. One patient is presented twice, as both shoulders were symptomatic (n=9). Plain film examination (9/9) failed to indicate a structural cause of shoulder pain in any of the patients. MR examination demonstrated abnormally increased T2 signal in the distal clavicle in all nine cases and no other cause for AC joint pain. Three patients responded to a course of conservative therapy. Six experienced refractory pain despite conservative therapy. Resection of the distal clavicle was performed in five of the six cases. All patients who underwent resection of the distal clavicle experienced complete resolution of AC joint pain. A retrospective review of the dictated reports for all shoulder MR imaging examinations performed at out institution over a 25 month period (August 1996 to September 1998; n=761) demonstrated a 12.5% incidence of abnormally increased T2 signal in the distal clav-icle.Conclusions. Increased T2 signal in the distal clavicle

  15. Increased T2 signal intensity in the distal clavicle: incidence and clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Fiorella, D.; Helms, C.A. [Dept. of Radiology, Duke Univ., Durham, NC (United States); Speer, K.P. [Dept. of Orthopedic Surgery, Duke Univ., Durham, NC (United States)

    2000-12-01

    Objective. The objectives of the current study were (1) to quantify the incidence of increased T2 signal in the distal clavicle and (2) to assess the clinical significance of this finding in patients with chronic acromioclavicular (AC) joint pain.Design and patients. Eight patients (five male and three female, 15-41 years of age) with disabling shoulder pain localized to the AC joint and marked increased T2 signal in the distal clavicle are presented. These eight patients underwent MR examination over a 25 month period (August 1996 to September 1998). The dictated reports of all shoulder MR examinations conducted over this same time period were reviewed retrospectively for the presence of signal abnormality in the distal cla-vicle. Clinical data and, in five patients, findings at shoulder arthroscopy or open surgery, were correlated with the results of MR imaging. One patient underwent arthroscopy on both shoulders.Results. The selected eight patients each presented clinically with disabling shoulder pain localized to the AC joint. One patient is presented twice, as both shoulders were symptomatic (n=9). Plain film examination (9/9) failed to indicate a structural cause of shoulder pain in any of the patients. MR examination demonstrated abnormally increased T2 signal in the distal clavicle in all nine cases and no other cause for AC joint pain. Three patients responded to a course of conservative therapy. Six experienced refractory pain despite conservative therapy. Resection of the distal clavicle was performed in five of the six cases. All patients who underwent resection of the distal clavicle experienced complete resolution of AC joint pain. A retrospective review of the dictated reports for all shoulder MR imaging examinations performed at out institution over a 25 month period (August 1996 to September 1998; n=761) demonstrated a 12.5% incidence of abnormally increased T2 signal in the distal clav-icle.Conclusions. Increased T2 signal in the distal clavicle

  16. Mount Oku, Cameroon Volcanic Line

    African Journals Online (AJOL)

    and continental sectors especially for trace elements in basalts. ... continental sector of the trend is a complex .... values higher than those of HIMU but is within ...... (Mount Cameroon, Central Africa): petrogenetic implications. Miner. Petrol.,.

  17. Applications of a pnCCD detector coupled to columnar structure CsI(Tl) scintillator system in ultra high energy X-ray Laue diffraction

    Science.gov (United States)

    Shokr, M.; Schlosser, D.; Abboud, A.; Algashi, A.; Tosson, A.; Conka, T.; Hartmann, R.; Klaus, M.; Genzel, C.; Strüder, L.; Pietsch, U.

    2017-12-01

    Most charge coupled devices (CCDs) are made of silicon (Si) with typical active layer thicknesses of several microns. In case of a pnCCD detector the sensitive Si thickness is 450 μm. However, for silicon based detectors the quantum efficiency for hard X-rays drops significantly for photon energies above 10 keV . This drawback can be overcome by combining a pixelated silicon-based detector system with a columnar scintillator. Here we report on the characterization of a low noise, fully depleted 128×128 pixels pnCCD detector with 75×75 μm2 pixel size coupled to a 700 μm thick columnar CsI(Tl) scintillator in the photon range between 1 keV to 130 keV . The excellent performance of the detection system in the hard X-ray range is demonstrated in a Laue type X-ray diffraction experiment performed at EDDI beamline of the BESSY II synchrotron taken at a set of several GaAs single crystals irradiated by white synchrotron radiation. With the columnar structure of the scintillator, the position resolution of the whole system reaches a value of less than one pixel. Using the presented detector system and considering the functional relation between indirect and direct photon events Laue diffraction peaks with X-ray energies up to 120 keV were efficiently detected. As one of possible applications of the combined CsI-pnCCD system we demonstrate that the accuracy of X-ray structure factors extracted from Laue diffraction peaks can be significantly improved in hard X-ray range using the combined CsI(Tl)-pnCCD system compared to a bare pnCCD.

  18. Multi-spectral CCD camera system for ocean water color and seacoast observation

    Science.gov (United States)

    Zhu, Min; Chen, Shiping; Wu, Yanlin; Huang, Qiaolin; Jin, Weiqi

    2001-10-01

    One of the earth observing instruments on HY-1 Satellite which will be launched in 2001, the multi-spectral CCD camera system, is developed by Beijing Institute of Space Mechanics & Electricity (BISME), Chinese Academy of Space Technology (CAST). In 798 km orbit, the system can provide images with 250 m ground resolution and a swath of 500 km. It is mainly used for coast zone dynamic mapping and oceanic watercolor monitoring, which include the pollution of offshore and coast zone, plant cover, watercolor, ice, terrain underwater, suspended sediment, mudflat, soil and vapor gross. The multi- spectral camera system is composed of four monocolor CCD cameras, which are line array-based, 'push-broom' scanning cameras, and responding for four spectral bands. The camera system adapts view field registration; that is, each camera scans the same region at the same moment. Each of them contains optics, focal plane assembly, electrical circuit, installation structure, calibration system, thermal control and so on. The primary features on the camera system are: (1) Offset of the central wavelength is better than 5 nm; (2) Degree of polarization is less than 0.5%; (3) Signal-to-noise ratio is about 1000; (4) Dynamic range is better than 2000:1; (5) Registration precision is better than 0.3 pixel; (6) Quantization value is 12 bit.

  19. Micro-inverter solar panel mounting

    Science.gov (United States)

    Morris, John; Gilchrist, Phillip Charles

    2016-02-02

    Processes, systems, devices, and articles of manufacture are provided. Each may include adapting micro-inverters initially configured for frame-mounting to mounting on a frameless solar panel. This securement may include using an adaptive clamp or several adaptive clamps secured to a micro-inverter or its components, and using compressive forces applied directly to the solar panel to secure the adaptive clamp and the components to the solar panel. The clamps can also include compressive spacers and safeties for managing the compressive forces exerted on the solar panels. Friction zones may also be used for managing slipping between the clamp and the solar panel during or after installation. Adjustments to the clamps may be carried out through various means and by changing the physical size of the clamps themselves.

  20. BVRI CCD photometry of the metal-poor globular cluster M68 (NGC 4590)

    International Nuclear Information System (INIS)

    Alcaino, G.; Liller, W.; Alvarado, F.; Wenderoth, E.

    1990-01-01

    BVRI photometry of the low metallicity globular cluster M68 (NGC 4590) was obtained with a CCD camera and the 2.2-m ESO telescope. The resulting BV color-magnitude diagrams are compared with the observations of McClure et al. (1987). The observations are also compared with theoretical isochrones, yielding a cluster age of 13 Gyr with a likely external uncertainty of 2 or 3 Gyr. 25 refs

  1. Automated CCD camera characterization. 1998 summer research program for high school juniors at the University of Rochester's Laboratory for Laser Energetics. Student research reports

    International Nuclear Information System (INIS)

    Silbermann, J.

    1999-03-01

    The OMEGA system uses CCD cameras for a broad range of applications. Over 100 video rate CCD cameras are used for such purposes as targeting, aligning, and monitoring areas such as the target chamber, laser bay, and viewing gallery. There are approximately 14 scientific grade CCD cameras on the system which are used to obtain precise photometric results from the laser beam as well as target diagnostics. It is very important that these scientific grade CCDs are properly characterized so that the results received from them can be evaluated appropriately. Currently characterization is a tedious process done by hand. The operator must manually operate the camera and light source simultaneously. Because more exposures means more accurate information on the camera, the characterization tests can become very length affairs. Sometimes it takes an entire day to complete just a single plot. Characterization requires the testing of many aspects of the camera's operation. Such aspects include the following: variance vs. mean signal level--this should be proportional due to Poisson statistics of the incident photon flux; linearity--the ability of the CCD to produce signals proportional to the light it received; signal-to-noise ratio--the relative magnitude of the signal vs. the uncertainty in that signal; dark current--the amount of noise due to thermal generation of electrons (cooling lowers this noise contribution significantly). These tests, as well as many others, must be conducted in order to properly understand a CCD camera. The goal of this project was to construct an apparatus that could characterize a camera automatically

  2. Geology of the Ugashik-Mount Peulik Volcanic Center, Alaska

    Science.gov (United States)

    Miller, Thomas P.

    2004-01-01

    The Ugashik-Mount Peulik volcanic center, 550 km southwest of Anchorage on the Alaska Peninsula, consists of the late Quaternary 5-km-wide Ugashik caldera and the stratovolcano Mount Peulik built on the north flank of Ugashik. The center has been the site of explosive volcanism including a caldera-forming eruption and post-caldera dome-destructive activity. Mount Peulik has been formed entirely in Holocene time and erupted in 1814 and 1845. A large lava dome occupies the summit crater, which is breached to the west. A smaller dome is perched high on the southeast flank of the cone. Pyroclastic-flow deposits form aprons below both domes. One or more sector-collapse events occurred early in the formation of Mount Peulik volcano resulting in a large area of debris-avalanche deposits on the volcano's northwest flank. The Ugashik-Mount Peulik center is a calcalkaline suite of basalt, andesite, dacite, and rhyolite, ranging in SiO2 content from 51 to 72 percent. The Ugashik-Mount Peulik magmas appear to be co-genetic in a broad sense and their compositional variation has probably resulted from a combination of fractional crystallization and magma-mixing. The most likely scenario for a future eruption is that one or more of the summit domes on Mount Peulik are destroyed as new magma rises to the surface. Debris avalanches and pyroclastic flows may then move down the west and, less likely, east flanks of the volcano for distances of 10 km or more. A new lava dome or series of domes would be expected to form either during or within some few years after the explosive disruption of the previous dome. This cycle of dome disruption, pyroclastic flow generation, and new dome formation could be repeated several times in a single eruption. The volcano poses little direct threat to human population as the area is sparsely populated. The most serious hazard is the effect of airborne volcanic ash on aircraft since Mount Peulik sits astride heavily traveled air routes connecting the U

  3. Distal triceps injuries (including snapping triceps): A systematic review of the literature.

    Science.gov (United States)

    Shuttlewood, Kimberley; Beazley, James; Smith, Christopher D

    2017-06-18

    To review current literature on types of distal triceps injury and determine diagnosis and appropriate management. We performed a systematic review in PubMed, Cochrane and EMBASE using the terms distal triceps tears and snapping triceps on the 10 th January 2017. We excluded all animal, review, foreign language and repeat papers. We reviewed all papers for relevance and of the papers left we were able to establish the types of distal triceps injury, how these injuries are diagnosed and investigated and the types of management of these injuries including surgical. The results are then presented in a review paper format. Three hundred and seventy-nine papers were identified of which 65 were relevant to distal triceps injuries. After exclusion we had 47 appropriate papers. The papers highlighted 2 main distal triceps injuries: Distal triceps tears and snapping triceps. Triceps tear are more common in males than females occurring in the 4 th -5 th decade of life and often due to a direct trauma but are also strongly associated with weightlifting and American football. The tears are diagnosed by history and clinically with a palpable gap. Diagnosis can be confirmed with the use of ultrasound (US) and magnetic resonance imaging. Treatment depends on type of tear. Partial tears can be treated conservatively with bracing and physio whereas acute tears need repair either open or arthroscopic using suture anchor or bone tunnel techniques with similar success. Chronic tears often need augmenting with tendon allograft or autograft. Snapping triceps are also seen more in men than women but at a mean age of 32 years. They are characterized by a snapping sensation mostly medially and can be associated with ulna nerve subluxation and ulna nerve symptoms. US is the diagnostic modality of choice due to its dynamic nature and to differentiate between snapping triceps tendon or ulna nerve. Treatment is conservative initially with activity avoidance and if that fails surgical

  4. Nontraumatic osteonecrosis of the distal pole of the scaphoid

    Directory of Open Access Journals (Sweden)

    Bhavuk Garg

    2011-01-01

    Full Text Available Post traumatic osteonecrosis of distal pole of scaphoid is very rare. We present a case of 34 years old male, drill operator by occupation with nontraumatic osteonecrosis of distal pole of the scaphoid. The patient was managed conservatively and was kept under regular follow-up every three months. The patient was also asked to change his profession. Two years later, the patient had no pain and had mild restriction of wrist movements (less than 15 degrees in either direction. The radiographs revealed normal density of the scaphoid suggesting revascularization.

  5. Alternative mounting media for preservation of some protozoa.

    Science.gov (United States)

    Criado-Fornelio, A; Heredero-Bermejo, I; Pérez-Serrano, J

    2014-10-01

    Protozoa resistant stages are disintegrated when mounted in toluene-based media. To overcome such problem, three toluene-free mountants were tested on preserve Acanthamoeba spp and gregarines. Two commercial glues based on cyanoacrylate or trimethoxysilane were suitable for preserving both cysts and trophozoites. Hoyer's medium showed good results for mounting gregarine oocysts. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Hole-thru-laminate mounting supports for photovoltaic modules

    Science.gov (United States)

    Wexler, Jason; Botkin, Jonathan; Culligan, Matthew; Detrick, Adam

    2015-02-17

    A mounting support for a photovoltaic module is described. The mounting support includes a pedestal having a surface adaptable to receive a flat side of a photovoltaic module laminate. A hole is disposed in the pedestal, the hole adaptable to receive a bolt or a pin used to couple the pedestal to the flat side of the photovoltaic module laminate.

  7. CT virtual reality in the preoperative workup of malunited distal radius fractures: preliminary results

    International Nuclear Information System (INIS)

    Rieger, Michael; Gruber, Hannes; Jaschke, Werner R.; Gabl, Markus; Mallouhi, Ammar

    2005-01-01

    Our objective was to evaluate the usefulness of CT virtual preoperative planning in the surgical repositioning of malunited distal radius fracture. Eleven patients with malunited distal radius fracture underwent multislice CT of both wrists. A preoperative workup was performed in a virtual reality environment created from the CT data sets. Virtual planning comprised three main procedures, carrying out the virtual osteotomy of the radius, prediction of the final position of the distal radius after osteotomy and computer-assisted manufacturing of a repositioning device, which was later placed at the surgical osteotomy site to reposition objectively the distal radius fragment before fixation with the osteosynthesis. All patients tolerated the surgical procedure well. During surgery, the orthopedic surgeons were not required in any of the cases to alter the position of the distal radius that was determined by the repositioning device. At postoperative follow-up, the anatomic relationship of the distal radius was restored (radial inclination, 21.4 ; volar tilt, 10.3 ; ulnar variance, 0.5 mm). Clinically, a significant improvement of pronation (P=0.012), supination (P=0.01), flexion (P=0.001) and extension (P=0.006) was achieved. Pain decreased from 54 to 7 points. CT virtual reality is a valuable adjunct for the preoperative workup and surgical reposition of malunited distal radius fractures. (orig.)

  8. MINIMUM INCISION PERCUTANEOUS PLATE OSTEOSYNTHESIS FOR DISTAL FIBULAR FRACTURES: A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Ramkumar Reddy

    2015-09-01

    Full Text Available Distal fibular fractures are usually communitted and most of the times osteoporotic especially if they are occurring in females and in geriatric age group. These fractures are usu ally associated with other fractures, which necessitates them to be fixed accurately. Owing to the fact that distal fragment is subcutaneous with scanty soft tissue over bone, which pose these fracture fixations become difficult by open methods in view of wound healing. A prospective study of 26 patients with distal fibular fractures were treated with MIPPO with hook plate were healed with less complications and better outcome. With this background we suggest a minimally invasive incision over proximal frag ment where sufficient soft tissue cover is present. From there pushing the special hook plate subperiosteally to distal fragment, hooking the tip of fibula and fixing the proximal fragment after reduction gives a simple and effective stable fixation

  9. Distal insertions of the semimembranosus tendon: MR imaging with anatomic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Maeseneer, Michel de [Universitair Ziekenhuis Brussel, Department of Radiology, Jette, Brussels (Belgium); Vrije Universiteit Brussel, Department of Experimental Anatomy, Brussels (Belgium); Shahabpour, Maryam; Milants, Annemieke; Ridder, Filip de; Mey, Johan de [Universitair Ziekenhuis Brussel, Department of Radiology, Jette, Brussels (Belgium); Lenchik, Leon [Wake Forest University, Department of Radiology, Winston-Salem, NC (United States); Cattrysse, Erik [Vrije Universiteit Brussel, Department of Experimental Anatomy, Brussels (Belgium)

    2014-06-15

    The purpose of this study is to investigate the distal insertions of the semimembranosus tendon with MR imaging, correlated with findings in cadavers. Four fresh cadaveric specimens were studied with 3-T MR imaging. Sequences included proton density (PD) sequences (TE, 13; TR, 4957; FOV, 170 x 170; matrix, 424 x 413; NA, 2; slice thickness, 2.5 mm) in the axial, coronal, and sagittal planes and 3D fast field echo (FFE) sequences (TR 9.4; TE 6.9; FOV, 159 x 105; matrix, 200 x 211; NA, 2; slice thickness, 0.57 mm). One specimen was dissected and three specimens were sectioned with a bandsaw in the axial, coronal, and sagittal plane. The sections were photographed and correlated with MR images. To standardize the analysis, the semimembranosus muscle and tendon were assessed at seven levels for the axial sections, and at three levels for the coronal and sagittal sections. Anatomic dissection revealed six insertions of the distal semimembranosus tendon: direct arm, anterior arm, posterior oblique ligament extension, oblique popliteal ligament extension, distal tibial expansion (popliteus aponeurosis), and meniscal arm. Axial MR images showed five of six insertions: direct arm, anterior arm, oblique popliteal ligament extension, posterior oblique ligament extension, and distal tibial expansion. Sagittal MR images showed four of six insertions: direct arm, anterior arm, oblique popliteal ligament arm, and distal tibial expansion. Sagittal MR images were ideal for showing the direct arm insertion, but were less optimal than the axial images for showing the other insertions. The anterior arm was seen but volume averaging was present with the gracilis tendon. Coronal MR images optimally revealed the anterior arm, although magic angle artifact was present at its posterior aspect. The common semimembranosus tendon and meniscal arm were also well depicted. The division in anterior arm, direct arm, and oblique popliteal ligament arm was poorly seen on coronal images due to

  10. Three-dimensional repositioning accuracy of semiadjustable articulator cast mounting systems.

    Science.gov (United States)

    Tan, Ming Yi; Ung, Justina Youlin; Low, Ada Hui Yin; Tan, En En; Tan, Keson Beng Choon

    2014-10-01

    In spite of its importance in prosthesis precision and quality, the 3-dimensional repositioning accuracy of cast mounting systems has not been reported in detail. The purpose of this study was to quantify the 3-dimensional repositioning accuracy of 6 selected cast mounting systems. Five magnetic mounting systems were compared with a conventional screw-on system. Six systems on 3 semiadjustable articulators were evaluated: Denar Mark II with conventional screw-on mounting plates (DENSCR) and magnetic mounting system with converter plates (DENCON); Denar Mark 330 with in-built magnetic mounting system (DENMAG) and disposable mounting plates; and Artex CP with blue (ARTBLU), white (ARTWHI), and black (ARTBLA) magnetic mounting plates. Test casts with 3 high-precision ceramic ball bearings at the mandibular central incisor (Point I) and the right and left second molar (Point R; Point L) positions were mounted on 5 mounting plates (n=5) for all 6 systems. Each cast was repositioned 10 times by 4 operators in random order. Nine linear (Ix, Iy, Iz; Rx, Ry, Rz; Lx, Ly, Lz) and 3 angular (anteroposterior, mediolateral, twisting) displacements were measured with a coordinate measuring machine. The mean standard deviations of the linear and angular displacements defined repositioning accuracy. Anteroposterior linear repositioning accuracy ranged from 23.8 ±3.7 μm (DENCON) to 4.9 ±3.2 μm (DENSCR). Mediolateral linear repositioning accuracy ranged from 46.0 ±8.0 μm (DENCON) to 3.7 ±1.5 μm (ARTBLU), and vertical linear repositioning accuracy ranged from 7.2 ±9.6 μm (DENMAG) to 1.5 ±0.9 μm (ARTBLU). Anteroposterior angular repositioning accuracy ranged from 0.0084 ±0.0080 degrees (DENCON) to 0.0020 ±0.0006 degrees (ARTBLU), and mediolateral angular repositioning accuracy ranged from 0.0120 ±0.0111 degrees (ARTWHI) to 0.0027 ±0.0008 degrees (ARTBLU). Twisting angular repositioning accuracy ranged from 0.0419 ±0.0176 degrees (DENCON) to 0.0042 ±0.0038 degrees

  11. Sensor mount assemblies and sensor assemblies

    Science.gov (United States)

    Miller, David H [Redondo Beach, CA

    2012-04-10

    Sensor mount assemblies and sensor assemblies are provided. In an embodiment, by way of example only, a sensor mount assembly includes a busbar, a main body, a backing surface, and a first finger. The busbar has a first end and a second end. The main body is overmolded onto the busbar. The backing surface extends radially outwardly relative to the main body. The first finger extends axially from the backing surface, and the first finger has a first end, a second end, and a tooth. The first end of the first finger is disposed on the backing surface, and the tooth is formed on the second end of the first finger.

  12. Enclavado endomedular en fracturas del tercio distal de la tibia

    OpenAIRE

    Arroquy, Damian; Chahla, Jorge; Gomez Rodriguez, Gustavo; Cid Casteulani, Alberto; Svarzchtein, Santiago; Gomez, Diego; Pesciallo, Cesar

    2015-01-01

    Objetivo: Describir los resultados obtenidos con el enclavado endomedular acerrojado en pacientes con fractura del tercio distal de la tibia. Materiales y Métodos: Se incluyeron pacientes con fracturas desplazadas del tercio distal de la tibia, tratadas con clavo endomedular. La muestra incluyo 35 pacientes. El tiempo de seguimiento posoperatorio fue de 29.2 meses. Se evaluaron el tiempo de consolidacion, la consolidacion viciosa y las complicaciones. Los resultados funcionales se determinaro...

  13. Robotic versus Laparoscopic Distal Pancreatectomy: A Meta-Analysis of Short-Term Outcomes.

    Science.gov (United States)

    Zhou, Jia-Yu; Xin, Chang; Mou, Yi-Ping; Xu, Xiao-Wu; Zhang, Miao-Zun; Zhou, Yu-Cheng; Lu, Chao; Chen, Rong-Gao

    2016-01-01

    To compare the safety and efficacy of robotic-assisted distal pancreatectomy (RADP) and laparoscopic distal pancreatectomy (LDP). A literature search of PubMed, EMBASE, and the Cochrane Library database up to June 30, 2015 was performed. The following key words were used: pancreas, distal pancreatectomy, pancreatic, laparoscopic, laparoscopy, robotic, and robotic-assisted. Fixed and random effects models were applied. Study quality was assessed using the Newcastle-Ottawa Scale. Seven non-randomized controlled trials involving 568 patients met the inclusion criteria. Compared with LDP, RADP was associated with longer operating time, lower estimated blood loss, a higher spleen-preservation rate, and shorter hospital stay. There was no significant difference in transfusion, conversion to open surgery, R0 resection rate, lymph nodes harvested, overall complications, severe complications, pancreatic fistula, severe pancreatic fistula, ICU stay, total cost, and 30-day mortality between the two groups. RADP is a safe and feasible alternative to LDP with regard to short-term outcomes. Further studies on the long-term outcomes of these surgical techniques are required. To date, there is no consensus on whether laparoscopic or robotic-assisted distal pancreatectomy is more beneficial to the patient. This is the first meta-analysis to compare laparoscopic and robotic-assisted distal pancreatectomy. We found that robotic-assisted distal pancreatectomy was associated with longer operating time, lower estimated blood loss, a higher spleen-preservation rate, and shorter hospital stay. There was no significant difference in transfusion, conversion to open surgery, overall complications, severe complications, pancreatic fistula, severe pancreatic fistula, ICU stay, total cost, and 30-day mortality between the two groups.

  14. Charge loss experiments in surface channel CCD's explained by the McWhorter interface states model

    NARCIS (Netherlands)

    Penning De Vries, R.G.M.; Wallinga, Hans

    1985-01-01

    On the basis of the McWhorter interface states model the CCD charge loss is derived as a function of bias charge, signal charge and channel width. As opposed to existing models, the charge loss is now attributed to interface states in the entire gate area, even for high bias charge levels.

  15. Blowhole colostomy for the urgent management of distal large bowel obstruction.

    Science.gov (United States)

    Kasten, Kevin R; Midura, Emily F; Davis, Bradley R; Rafferty, Janice F; Paquette, Ian M

    2014-05-01

    Complete obstruction of the distal colon or rectum often presents as a surgical emergency. This study evaluated the efficacy of blowhole colostomy versus transverse loop colostomy for the emergent management of distal large intestinal obstruction. Retrospective chart review of all colostomy procedures (CPT 44320) performed for complete distal large bowel obstruction during the past 6 y in a university hospital practice was undertaken. Blowhole was compared with loop colostomy with a primary endpoint of successful colonic decompression. One hundred forty-one patients underwent colostomy creation during the study period. Of these, 61 were completed for acute obstruction of the distal colon or rectum (19 blowhole versus 42 loop colostomy). No differences between study groups were seen in age, gender, body mass index, malnutrition, American Society of Anesthesiology class, time to liquid or regular diet, 30-d or inhospital mortality, or rates of complications. Patients undergoing blowhole colostomy had significantly higher cecal diameters at diagnosis (9.14 versus 7.31 cm, P = 0.0035). Operative time was shorter in blowhole procedures (43 versus 51 min, P = 0.017). Postoperative length of stay was significantly shorter for blowhole colostomy (6 versus 8 d, P = 0.014). The primary endpoint of successful colonic decompression was met in all colostomy patients. Diverting blowhole colostomy is a safe, quick, and effective procedure for the urgent management of distal colonic obstruction associated with obstipation and massive distention. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. A Binary Offset Effect in CCD Readout and Its Impact on Astronomical Data

    Science.gov (United States)

    Boone, K.; Aldering, G.; Copin, Y.; Dixon, S.; Domagalski, R. S.; Gangler, E.; Pecontal, E.; Perlmutter, S.

    2018-06-01

    We have discovered an anomalous behavior of CCD readout electronics that affects their use in many astronomical applications. An offset in the digitization of the CCD output voltage that depends on the binary encoding of one pixel is added to pixels that are read out one, two, and/or three pixels later. One result of this effect is the introduction of a differential offset in the background when comparing regions with and without flux from science targets. Conventional data reduction methods do not correct for this offset. We find this effect in 16 of 22 instruments investigated, covering a variety of telescopes and many different front-end electronics systems. The affected instruments include LRIS and DEIMOS on the Keck telescopes, WFC3 UVIS and STIS on HST, MegaCam on CFHT, SNIFS on the UH88 telescope, GMOS on the Gemini telescopes, HSC on Subaru, and FORS on VLT. The amplitude of the introduced offset is up to 4.5 ADU per pixel, and it is not directly proportional to the measured ADU level. We have developed a model that can be used to detect this “binary offset effect” in data, and correct for it. Understanding how data are affected and applying a correction for the effect is essential for precise astronomical measurements.

  17. BV photographic and CCD photometry of IC 4651

    International Nuclear Information System (INIS)

    Anthony-Twarog, B.J.; Mukherjee, K.; Twarog, B.A.; Caldwell, N.

    1988-01-01

    A BV photometric survey in IC 4651 based on photographic and CCD material calibrated with photoelectric photometry from Eggen (1971) and Anthony-Twarog and Twarog (1987) has been completed. The color-magnitude diagram is consistent with an age of 2.4 + or - 0.3 x 10 to the 9th yr derived by comparison with the isochrones of VandenBerg (1985) if the apparent distance modulus and reddening derived from uvby photometry in Anthony-Twarog and Twarog (1987) are employed. While evidence is found of a hook in the upper main sequence, no evidence is found of a significantly bifurcated main sequence for this cluster, although it is similar in age to NGC 752 and NGC 3680, where this phenomenon has been noted. Finally, the survey has not resolved the apparent deficit of main-sequence stars fainter than V = 14.5 noted in Anthony-Twarog and Twarog (1987). 16 references

  18. The January 2006 Volcanic-Tectonic Earthquake Swarm at Mount Martin, Alaska

    Science.gov (United States)

    Dixon, James P.; Power, John A.

    2009-01-01

    On January 8, 2006, a swarm of volcanic-tectonic earthquakes began beneath Mount Martin at the southern end of the Katmai volcanic cluster. This was the first recorded swarm at Mount Martin since continuous seismic monitoring began in 1996. The number of located earthquakes increased during the next four days, reaching a peak on January 11. For the next two days, the seismic activity decreased, and on January 14, the number of events increased to twice the previous day's total. Following this increase in activity, seismicity declined, returning to background levels by the end of the month. The Alaska Volcano Observatory located 860 earthquakes near Mount Martin during January 2006. No additional signs of volcanic unrest were noted in association with this earthquake swarm. The earthquakes in the Mount Martin swarm, relocated using the double difference technique, formed an elongated cluster dipping to the southwest. Focal mechanisms beneath Mount Martin show a mix of normal, thrust, and strike-slip solutions, with normal focal mechanisms dominating. For earthquakes more than 1 km from Mount Martin, all focal mechanisms showed normal faulting. The calculated b-value for the Mount Martin swarm is 0.98 and showed no significant change before, during, or after the swarm. The triggering mechanism for the Mount Martin swarm is unknown. The time-history of earthquake occurrence is indicative of a volcanic cause; however, there were no low-frequency events or observations, such as increased steaming associated with the swarm. During the swarm, there was no change in the b-value, and the distribution and type of focal mechanisms were similar to those in the period before the anomalous activity. The short duration of the swarm, the similarity in observed focal mechanisms, and the lack of additional signs of unrest suggest this swarm did not result from a large influx of magma within the shallow crust beneath Mount Martin.

  19. Low-stress mounting configuration design for large aperture laser transport mirror

    Science.gov (United States)

    Zhang, Zheng; Quan, Xusong; Yao, Chao; Wang, Hui

    2016-10-01

    TM1-6S1 large aperture laser transport mirror is a crucial optical unit of high power solid-state laser in the Inertial Confinement Fusion (ICF) facility. This article focuses on the low-stress and precise mounting method of large-aperture mirror. Based on the engineering practice of SG-III, the state-of-the-art and key problems of current mounting configuration are clarified firstly. Subsequently, a brand new low-stress mounting configuration with flexure supports is proposed. Opto-mechanical model of the mirror under mounting force is built up with elastic mechanics theory. Further, numerical methods and field tests are employed to verify the favorable load uniform capacity and load adjust capacity of flexure supports. With FEM, the relation between the mounting force from new configuration and the mirror surface distortion (wavefront error) is clarified. The novel mounting method of large aperture optics could be not only used on this laser transport mirror, but also on the other transmission optics and large crystals in ICF facilities.

  20. Head-Mounted Display Technology for Low Vision Rehabilitation and Vision Enhancement

    Science.gov (United States)

    Ehrlich, Joshua R.; Ojeda, Lauro V.; Wicker, Donna; Day, Sherry; Howson, Ashley; Lakshminarayanan, Vasudevan; Moroi, Sayoko E.

    2017-01-01

    Purpose To describe the various types of head-mounted display technology, their optical and human factors considerations, and their potential for use in low vision rehabilitation and vision enhancement. Design Expert perspective. Methods An overview of head-mounted display technology by an interdisciplinary team of experts drawing on key literature in the field. Results Head-mounted display technologies can be classified based on their display type and optical design. See-through displays such as retinal projection devices have the greatest potential for use as low vision aids. Devices vary by their relationship to the user’s eyes, field of view, illumination, resolution, color, stereopsis, effect on head motion and user interface. These optical and human factors considerations are important when selecting head-mounted displays for specific applications and patient groups. Conclusions Head-mounted display technologies may offer advantages over conventional low vision aids. Future research should compare head-mounted displays to commonly prescribed low vision aids in order to compare their effectiveness in addressing the impairments and rehabilitation goals of diverse patient populations. PMID:28048975

  1. Robotic mounting of ATLAS barrel SCT modules

    International Nuclear Information System (INIS)

    Nickerson, R.B.; Viehhauser, G.; Wastie, R.; Terada, S.; Unno, Y.; Kohriki, T.; Ikegami, Y.; Hara, K.; Kobayashi, H.; Barbier, G.; Clark, A.G.; Perrin, E.; Carter, A.A.; Mistry, J.; Morris, J.

    2006-01-01

    The 2112 silicon detector modules of the barrel part of the ATLAS SemiConductor Tracker (SCT) have been mounted on their carbon fibre support structure. Module insertion, placement and fixing were performed by robotic assembly tooling. We report on our experience with this assembly method. Part of the mounting sequence involves a partial survey of elements of the support structure which is needed to align the modules properly during insertion. An analysis of these data is used to estimate the positional accuracy of the robots

  2. Three-stage treatment protocol for recalcitrant distal femoral nonunion.

    Science.gov (United States)

    Ma, Ching-Hou; Chiu, Yen-Chun; Tu, Yuan-Kun; Yen, Cheng-Yo; Wu, Chin-Hsien

    2017-04-01

    In this study, we proposed a three-stage treatment protocol for recalcitrant distal femoral nonunion and aimed to analyze the clinical results. We retrospective reviewed 12 consecutive patients with recalcitrant distal femoral nonunion undergoing our three-stage treatment protocol from January 2010 to December 2014 in our institute. The three-stage treatment protocol comprised debridement of the nonunion site, lengthening to eliminate leg length discrepancy, deformity correction, stabilization with a locked plate, filling of the defect with cement spacer for inducing membrane formation, and bone reconstruction using a cancellous bone autograft (Masquelet technique) or free vascularized fibular bone graft. The bone union time, wound complication, lower limbs alignment, amount of lengthening, knee range of motion, and functional outcomes were evaluated. Osseous union with angular deformity lengthening was 5.88 cm (range 3.5-12 cm). Excellent or good outcomes were obtained in 9 patients. Although the current study involved only a small number of patients and the intervention comprised three stages, we believe that such a protocol may be a valuable alternative for the treatment of recalcitrant distal femoral nonunion.

  3. National Ingition Facility subsystem design requirements optical mounts SSDR 1.4.4

    International Nuclear Information System (INIS)

    Richardson, M.

    1996-01-01

    This SSDR establishes the performance, design, development and test requirements for NIF Beam Transport Optomechanical Subsystems. optomechanical Subsystems includes the mounts for the beam transport mirrors, LMl - LM8, the polarizer mount, and the spatial filter lens mounts

  4. Smear correction of highly variable, frame-transfer CCD images with application to polarimetry.

    Science.gov (United States)

    Iglesias, Francisco A; Feller, Alex; Nagaraju, Krishnappa

    2015-07-01

    Image smear, produced by the shutterless operation of frame-transfer CCD detectors, can be detrimental for many imaging applications. Existing algorithms used to numerically remove smear do not contemplate cases where intensity levels change considerably between consecutive frame exposures. In this report, we reformulate the smearing model to include specific variations of the sensor illumination. The corresponding desmearing expression and its noise properties are also presented and demonstrated in the context of fast imaging polarimetry.

  5. The use of a CCD imaging system for X-ray film intensity measurement

    International Nuclear Information System (INIS)

    Grigg, M.W.; Barnea, Z.

    1994-01-01

    The use of a simple CCD-based imaging system for digitizing and x-ray film image is demonstrated. A method of extending the region of linear response of the film based upon an analytic representation of the observed response to a series of increasing exposures is described. The validity of the procedure is illustrated through an example of the absolute intensity measurement of a reflection of cadmium sulphide. 3 refs., 7 figs

  6. Jets from young stars - CCD imaging, long-slit spectroscopy, and interpretation of existing data

    International Nuclear Information System (INIS)

    Mundt, R.; Brugel, E.W.; Buehrke, T.

    1987-01-01

    High-velocity jets and collimated outflows are now recognized as phenomena commonly associated with young stars. New CCD imaging of five objects, and in particular spatially resolved spectroscopy of eight highly-collimated flows, are discussed. Through the CCD imaging, three new jets have been discovered. It is shown that several previously known Herbig-Haro objects have extended bow-shock-like structures. In most of the latter cases, a jet is pointing from the star toward the bow-shock apex. The concave side of the bow-shock structure is in all cases oriented toward the outflow source. Using a data base of about 20 known jets, a detailed list of observational criteria describing these phenomena is compiled. A physical description and interpretation is presented which discusses the origin of knots in these jets and other structures, the relationship between jets and Herbig-Haro objects, the dissipation of energy along the jet due to internal shocks, the physical parameters, the relationship of optical jets to molecular outflows, and time scales for outflow activity. A short discussion of the driving sources for these jets is also included. 116 references

  7. Development of a CCD based system called DIGITRACK for automatic track counting and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Molnar, J.; Somogyi, G.; Szilagyi, S.; Sepsy, K. (Magyar Tudomanyos Akademia, Debrecen. Atommag Kutato Intezete)

    1984-01-01

    We have developed, to the best of our knowledge, the first automatic track analysis system (DIGITRACK) in which the video signals are processed by a new type of video-receiver called charge-coupled device (CCD). The photosensitive semi-conductor device is a 2.5 cm long line imager of type Fairchild CCD 121HC which converts one row of the picture seen through a low magnification microscope into 1728 binary signals by a thresholding logic. The picture elements are analysed by a microcomputer equipped with two INTEL 8080 microprocessors and interfaced to a PDP-11/40 computer. The microcomputer also controls the motion of the stage of microscope. For pattern recognition and analysis a software procedure is developed which is able to differentiate between overlapping tracks and to determine the number, surface opening and x-y coordinates of the tracks occurring in a given detector area. The distribution of track densities and spot areas on the detector surface can be visualized on a graphic display. The DIGITRACK system has been tested for analysis of alpha-tracks registered in CR-39 and LR-115 detectors.

  8. Youngswick-Austin versus distal oblique osteotomy for the treatment of Hallux Rigidus.

    Science.gov (United States)

    Viladot, Antonio; Sodano, Luca; Marcellini, Lorenzo; Zamperetti, Marco; Hernandez, Elsa Sanchez; Perice, Ramon Viladot

    2017-08-01

    Hallux Rigidus is the most common degenerative joint pathology of the foot. Several procedures are described for the management of this deformity. In this prospective study we compared Youngswick-Austin and distal oblique osteotomy in the treatment of grade II Hallux Rigidus, in terms of clinical outcomes, efficacy and complications. Forty-six patients (50 feet) with moderate Hallux Rigidus (Regnauld grade II) were recruited and operated between March 2009 and December 2012. Surgical technique was Youngswick-Austin osteotomy (Group A) or distal oblique osteotomy (Group B). Mean follow-up was 42.7 ±12.2 (range, 24-70) months. Both groups achieved significant improvement of AOFAS score and first metatarsophalangeal joint range of motion (p value Austin and distal oblique osteotomies provides subjective patient improvement and increases the first metatarsophalangeal joint range of motion. The results of grade II Hallux Rigidus treatment were comparable when using a Youngswick-Austin or distal oblique osteotomy. Level II, prospective comparative study. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. TRPV3, a thermosensitive channel is expressed in mouse distal colon epithelium

    International Nuclear Information System (INIS)

    Ueda, Takashi; Yamada, Takahiro; Ugawa, Shinya; Ishida, Yusuke; Shimada, Shoichi

    2009-01-01

    The thermo-transient receptor potential (thermoTRP) subfamily is composed of channels that are important in nociception and thermo-sensing. Here, we show a selective expression of TRPV3 channel in the distal colon throughout the gastrointestinal tract. Expression analyses clearly revealed that TRPV3 mRNA and proteins were expressed in the superficial epithelial cells of the distal colon, but not in those of the stomach, duodenum or proximal colon. In a subset of primary epithelial cells cultured from the distal colon, carvacrol, an agonist for TRPV3, elevated cytosolic Ca 2+ concentration in a concentration-dependent manner. This response was inhibited by ruthenium red, a TRPV channel antagonist. Organotypic culture supported that the carvacrol-responsive cells were present in superficial epithelial cells. Moreover, application of carvacrol evoked ATP release in primary colonic epithelial cells. We conclude that TRPV3 is present in absorptive cells in the distal colon and may be involved in a variety of cellular functions.

  10. 32x32 HgCdTe/CCD infrared camera for the 2-5 micron range

    International Nuclear Information System (INIS)

    Monin, J.L.; Vauglin, I.; Sibille, F.

    1988-01-01

    The paper presents a complete infrared camera system, based on a high electron capacity detector (HgCdTe/CCD), that has been used under high background conditions to generate astronomical images. The performance of the system and some results are presented, and the use of such a detector in astronomy is discussed. 8 references

  11. Medición de posiciones astrométricas con CCD en la zona de Rup 21

    Science.gov (United States)

    Bustos Fierro, I. H.; Calderón, J. H.

    It is shown the utilization of the block adjustment method for the measurement of astrometric positions from a mosaic of sixteen CCD images with partial overlap, which were taken with the Telescope Jorge Sahade of CASLEO. The observations cover an area of 25' x 25' around the open cluster Rup21. The source of reference positions was ACT Reference Catalog. The internal error of the measured positions is analyzed, and the external error is estimated from the comparison with the catalog USNO-A. In this comparison it is found that the direct CCD images taken with focal reducer could be distorted by severe field curvature. The effect of the distortion presumably introduced by the optics is eliminated with the suitable corrections of the stellar positions measured on every frame, but a new systematic effect on scales of the entire field is observed, which could be due to the distribution of the reference stars.

  12. Fractures of the Distal Tibia Treated with Polyaxial Locking Plating

    OpenAIRE

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2008-01-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial in...

  13. Segmental reversal of distal small intestine in short bowel syndrome

    DEFF Research Database (Denmark)

    Grave, Pernille Kock; Thomsen, Sabrina Valentin; Clark, Pia Susanne

    2018-01-01

    were the influence on cell proliferation and mucosal architecture shown by histological analysis. Methods: Sixteen piglets underwent a 60% resection of the distal small intestine and were randomized into two groups. Group 1 short bowel syndrome alone (SBS) (n = 8) and group 2 with reversal of a distal...... small intestinal segment (SBS-RS) (n = 8). Body weight was measured daily and the pigs were euthanized after 1 month. Crypt depths, villus heights and muscle layers thicknesses were measured. For the evaluation of microvilli of the brush border of the epithelium and cell proliferation...... was found in the SBS group and increase in the thickness of the circular and longitudinal muscle layers in the SBS-RS group. In the distal ileal segment the longitudinal muscle layer thicknesses were increased in the SBS group. Otherwise, no significant changes were found. Conclusion: Reversal of a 20-cm...

  14. Some technical solutions on organization and technology of reactor room component mounting

    International Nuclear Information System (INIS)

    Romanovskij, V.I.

    1982-01-01

    Design of the production equipment for mounting sites of heat facilities of the Zaporozhe NPP is considered. Plan of the production equipment for mounting sites of heat facilities and flowsheet of mounting of supporting truss of the reactor are presented

  15. Polymethylmethacrylate-based luminescent solar concentrators with bottom-mounted solar cells

    International Nuclear Information System (INIS)

    Zhang, Yi; Sun, Song; Kang, Rui; Zhang, Jun; Zhang, Ningning; Yan, Wenhao; Xie, Wei; Ding, Jianjun; Bao, Jun; Gao, Chen

    2015-01-01

    Graphical abstract: - Highlights: • Bottom-mounted luminescent solar concentrators on dye-doped plates were studied. • The mechanism of transport process was proposed. • The fabricated luminescent solar concentrator achieved a gain of 1.38. • Power conversion efficiency of 5.03% was obtained with cell area coverage of 27%. • The lowest cost per watt of $1.89 was optimized with cell area coverage of 18%. - Abstract: Luminescent solar concentrators offer an attractive approach to concentrate sunlight economically without tracking, but the narrow absorption band of luminescent materials hinders their further development. This paper describes bottom-mounted luminescent solar concentrators on dye-doped polymethylmethacrylate plates that absorb not only the waveguided light but also the transmitted sunlight and partial fluorescent light in the escape cone. A series of bottom-mounted luminescent solar concentrators with size of 78 mm × 78 mm × 7 mm were fabricated and their gain and power conversion efficiency were investigated. The transport process of the waveguided light and the relationship between the bottom-mounted cells were studied to optimize the performance of the device. The bottom-mounted luminescent solar concentrator with cell area coverage of 9% displayed a cell gain of 1.38, to our best knowledge, which is the highest value for dye-doped polymethylmethacrylate plate luminescent solar concentrators. Power conversion efficiency as high as 5.03% was obtained with cell area coverage of 27%. Furthermore, the bottom-mounted luminescent solar concentrator was found to have a lowest cost per watt of $1.89 with cell area coverage of 18%. These results suggested that the fabricated bottom-mounted luminescent solar concentrator may have a potential in low-cost building integrated photovoltaic application

  16. Imaging of the Distal Tibiofibular Syndesmosis: Anatomy in Relation to Radiological Diagnosis

    NARCIS (Netherlands)

    J.J. Hermans (John)

    2011-01-01

    textabstractInjury to the distal tibiofibular syndesmosis can occur after an ankle sprain or after an acute ankle fracture. In an estimated 1-11% of all ankle sprains, injury of the distal tibiofibular syndesmosis occurs which is known as a high ankle sprain. However, depending on the type and

  17. Robotic versus Laparoscopic Distal Pancreatectomy: A Meta-Analysis of Short-Term Outcomes.

    Directory of Open Access Journals (Sweden)

    Jia-Yu Zhou

    Full Text Available To compare the safety and efficacy of robotic-assisted distal pancreatectomy (RADP and laparoscopic distal pancreatectomy (LDP.A literature search of PubMed, EMBASE, and the Cochrane Library database up to June 30, 2015 was performed. The following key words were used: pancreas, distal pancreatectomy, pancreatic, laparoscopic, laparoscopy, robotic, and robotic-assisted. Fixed and random effects models were applied. Study quality was assessed using the Newcastle-Ottawa Scale.Seven non-randomized controlled trials involving 568 patients met the inclusion criteria. Compared with LDP, RADP was associated with longer operating time, lower estimated blood loss, a higher spleen-preservation rate, and shorter hospital stay. There was no significant difference in transfusion, conversion to open surgery, R0 resection rate, lymph nodes harvested, overall complications, severe complications, pancreatic fistula, severe pancreatic fistula, ICU stay, total cost, and 30-day mortality between the two groups.RADP is a safe and feasible alternative to LDP with regard to short-term outcomes. Further studies on the long-term outcomes of these surgical techniques are required.To date, there is no consensus on whether laparoscopic or robotic-assisted distal pancreatectomy is more beneficial to the patient. This is the first meta-analysis to compare laparoscopic and robotic-assisted distal pancreatectomy. We found that robotic-assisted distal pancreatectomy was associated with longer operating time, lower estimated blood loss, a higher spleen-preservation rate, and shorter hospital stay. There was no significant difference in transfusion, conversion to open surgery, overall complications, severe complications, pancreatic fistula, severe pancreatic fistula, ICU stay, total cost, and 30-day mortality between the two groups.

  18. Pseudotumor of the distal common bile duct at endoscopic retrograde cholangiopancreatography

    Science.gov (United States)

    Tan, Justin H.; Coakley, Fergus V; Wang, Zhen J.; Poder, Liina; Webb, Emily; Yeh, Benjamin M.

    2010-01-01

    Background Prior studies have described a pseudocalculus appearance in the distal common bile duct as a normal variant at cholangiography. The objective of this study is to describe the occurrence of pseudotumor in the distal common bile duct at endoscopic retrograde cholangiopancreatography (ERCP). Methods Nine patients who underwent ERCP between May 2004 and July 2008 were identified as having a transient eccentric mural-based filling defect in the distal common bile duct. A single reader systematically reviewed all studies and recorded the imaging findings. Results The mean diameter of the filling defect was 9 mm (range, 5 to 11). Eight patients had resolution of the filling defect during the same ERCP or on a subsequent ERCP, and in 2 of these patients the inferior border of the filling defect was not well visualized. The other patient underwent surgical resection of a presumed tumor with no evidence of malignancy on surgical pathology. Conclusion An eccentric mural-based filling defect in the distal common bile duct can be artifactual in nature and may reflect transient contraction of the sphincter of Oddi. Recognition of this pseudotumor may help avoid unnecessary surgery. PMID:21724120

  19. Screening renal stone formers for distal renal tubular acidosis

    DEFF Research Database (Denmark)

    Osther, P J; Hansen, A B; Røhl, H F

    1989-01-01

    A group of 110 consecutive renal stone formers were screened for distal renal tubular acidosis (RTA) using morning fasting urinary pH (mfUpH) levels followed by a short ammonium chloride loading test in patients with levels above 6.0. In 14 patients (12.7%) a renal acidification defect was noted...... RTA in renal stone formers. Regardless of whether the acidification defect is primary or secondary to stone formation, however, all renal stone formers with distal RTA can expect to benefit from prophylactic alkaline therapy and it is recommended that the screening procedure, which is easy to use...

  20. Ofd1, a human disease gene, regulates the length and distal structure of centrioles.

    Science.gov (United States)

    Singla, Veena; Romaguera-Ros, Miriam; Garcia-Verdugo, Jose Manuel; Reiter, Jeremy F

    2010-03-16

    Centrosomes and their component centrioles represent the principal microtubule organizing centers of animal cells. Here, we show that the gene underlying orofaciodigital syndrome 1, Ofd1, is a component of the distal centriole that controls centriole length. In the absence of Ofd1, distal regions of centrioles, but not procentrioles, elongate abnormally. These long centrioles are structurally similar to normal centrioles but contain destabilized microtubules with abnormal posttranslational modifications. Ofd1 is also important for centriole distal appendage formation and centriolar recruitment of the intraflagellar transport protein Ift88. To model OFD1 syndrome in embryonic stem cells, we replaced the Ofd1 gene with missense alleles from human OFD1 patients. Distinct disease-associated mutations cause different degrees of excessive or decreased centriole elongation, all of which are associated with diminished ciliogenesis. Our results indicate that Ofd1 acts at the distal centriole to build distal appendages, recruit Ift88, and stabilize centriolar microtubules at a defined length. Copyright 2010 Elsevier Inc. All rights reserved.