WorldWideScience

Sample records for distal radius fracture

  1. Fractures of the bilateral distal radius and scaphoid: a case report

    Directory of Open Access Journals (Sweden)

    Ozkan Korhan

    2008-03-01

    Full Text Available Abstract Introduction Bilateral fractures of the distal radius and scaphoid are extremely rare injuries. Case presentation A patient with bilateral comminuted, displaced distal fractures of the radius and bilateral fractures of the scaphoid was treated via internal fixation of the scaphoid fractures with Herbert screws and internal fixation of the distal radius fractures with locked volar plating. Conclusion Rigid internal fixation of distal radius and scaphoid fractures is mandatory to start early active rehabilitation of the wrist without the need for wrist immobilization with a plaster or external skeletal fixation.

  2. Social Support Contributes to Outcomes following Distal Radius Fractures

    Directory of Open Access Journals (Sweden)

    Caitlin J. Symonette

    2013-01-01

    Full Text Available Background. Distal radius fractures are the most common fracture of the upper extremity and cause variable disability. This study examined the role of social support in patient-reported pain and disability at one year following distal radius fracture. Methods. The Medical Outcomes Study Social Support Survey was administered to a prospective cohort of 291 subjects with distal radius fractures at their baseline visit. Pearson correlations and stepwise linear regression models (F-to-remove 0.10 were used to identify whether social support contributes to wrist fracture outcomes. The primary outcome of pain and disability at one year was measured using the Patient Rated Wrist Evaluation. Results. Most injuries were low energy (67.5% and were treated nonoperatively (71.9%. Pearson correlation analysis revealed that higher reported social support correlated with improved Patient Rated Wrist Evaluation scores at 1 year, r(n=181=-0.22, P<0.05. Of the subscales within the Social Support Survey, emotional/informational support explained a significant proportion of the variance in 1-year Patient Rated Wrist Evaluation scores, R2=4.7%, F (1, 181 = 9.98, P<0.05. Conclusion. Lower emotional/informational social support at the time of distal radius fracture contributes a small but significant percentage to patient-reported pain and disability outcomes.

  3. MRI of fractures of the distal radius: comparison with conventional radiographs

    International Nuclear Information System (INIS)

    Spence, L.D.; Eustace, S.

    1998-01-01

    Objective. To compare the evaluation of fractures of the distal radius with MRI and conventional radiographs. To demonstrate the ability of MRI to detect unsuspected soft tissue derangement accompanying this common injury. Design and patients. Twenty-one consecutive inpatients admitted following fracture of the distal radius underwent preoperative evaluation with both conventional radiographs and MRI. In each case, analysis was made of both the osseous and soft tissue injury. MRI findings were compared with those identified on conventional radiographs and at subsequent surgical fixation. Results. Of 21 patients with fractures of the distal radius, 20 had extension to the radiocarpal articulation, 14 had distal radio-ulnar joint extension and 5 had avulsion of the ulnar styloid.Occult carpal bone fractures accompanying fracture of the distal radius were identified in two patients: one of the capitate and the other of the second metacarpal base. Ten patients (48%) had associated soft tissue injury: six patients had scapholunate ligament rupture, two patients had disruption of the triangular fibrocartilage, one patient had extensor carpi ulnaris tenosynovitis and one patient had a tear of a dorsal radiocarpal ligament. Of five patients with ulnar styloid avulsions, none had evidence of triangular fibrocartilage tears. Conclusion. MRI affords better evaluation of osseous injury accompanying distal radial fractures than conventional radiographs. Intra-articular soft tissue injury accompanies distal radial fractures in almost 50% of cases. Scapholunate ligament disruption commonly accompanies intra-articular fracture through the lunate facet of the distal radius. Fracture of the ulnar styloid is infrequently associated with tear of the triangular fibrocartilage. (orig.)

  4. MRI of fractures of the distal radius: comparison with conventional radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Spence, L.D.; Eustace, S. [Medical Center, Boston, MA (United States). Dept. of Radiol.; Savenor, A.; Nwachuku, I.; Tilsley, J. [Department of Orthopedics, Boston Medical Center, Boston, MA 02118 (United States)

    1998-05-01

    Objective. To compare the evaluation of fractures of the distal radius with MRI and conventional radiographs. To demonstrate the ability of MRI to detect unsuspected soft tissue derangement accompanying this common injury. Design and patients. Twenty-one consecutive inpatients admitted following fracture of the distal radius underwent preoperative evaluation with both conventional radiographs and MRI. In each case, analysis was made of both the osseous and soft tissue injury. MRI findings were compared with those identified on conventional radiographs and at subsequent surgical fixation. Results. Of 21 patients with fractures of the distal radius, 20 had extension to the radiocarpal articulation, 14 had distal radio-ulnar joint extension and 5 had avulsion of the ulnar styloid.Occult carpal bone fractures accompanying fracture of the distal radius were identified in two patients: one of the capitate and the other of the second metacarpal base. Ten patients (48%) had associated soft tissue injury: six patients had scapholunate ligament rupture, two patients had disruption of the triangular fibrocartilage, one patient had extensor carpi ulnaris tenosynovitis and one patient had a tear of a dorsal radiocarpal ligament. Of five patients with ulnar styloid avulsions, none had evidence of triangular fibrocartilage tears. Conclusion. MRI affords better evaluation of osseous injury accompanying distal radial fractures than conventional radiographs. Intra-articular soft tissue injury accompanies distal radial fractures in almost 50% of cases. Scapholunate ligament disruption commonly accompanies intra-articular fracture through the lunate facet of the distal radius. Fracture of the ulnar styloid is infrequently associated with tear of the triangular fibrocartilage. (orig.) With 5 figs., 16 refs.

  5. Factors associated with infection following open distal radius fractures.

    Science.gov (United States)

    Glueck, Dane A; Charoglu, Constantine P; Lawton, Jeffrey N

    2009-09-01

    Open fractures are often classified according to a system described by Gustilo and Anderson. However, this system was applied to open long bone fractures, which may not predict the incidence of infection in open metaphyseal fractures of the upper extremity. Other studies have found that wound contamination and systemic illness were the best predictors of infections in open hand fractures. Our study assessed infection in open distal radius fractures and identifies factors that are associated with these infections. We hypothesize that contamination, rather than absolute wound size, is the best predictor of infection associated with open distal radius fractures. A review by CPT code yielded 42 patients with open distal radius fractures between 1997 and 2002 treated at a level one trauma center. Medical records and radiographic follow-up were reviewed to assess the time to irrigation and debridement, the number of debridements in initial treatment period, the method of operative stabilization, the Gustilo and Anderson type of fracture, the Swanson type of fracture, and description of wound contamination. Forty-two patients were followed up for an average of 15 months (range 4 to 68 months). Twenty-four fractures were classified as Gustilo and Anderson type I, ten were type II, and eight were type III, 30 were Swanson type I, and 12 were Swanson type II. Five of the 42 fractures were considered contaminated. Two were exposed to fecal contamination. The others were contaminated with tar, dirt/grass, and gravel, respectively. Three of 42 (7%) fractures developed infections. All three infected cases received a single irrigation and debridement. Two of five contaminated fractures (40%) developed a polymicrobial infection. Both were exposed to fecal contamination and, therefore, considered Swanson type II fractures. They were classified as Gustilo and Anderson type II and IIIB based solely upon the size of the wound. Both required multiple debridements and eventually wrist

  6. Fractures of the distal radius in children: A retrospective evaluation

    Directory of Open Access Journals (Sweden)

    Selma Yazıcı

    2012-06-01

    Full Text Available Objectives: This study designed to evaluate the resultsof treatment, closed reduction and percutaneous wires, ofthe distal radius fractures in children.Materials and methods: A retrospective analysis wascarried out in children aged between 5-15 years who presentedwith a displaced fracture of the distal radius to ourhospital. They were initially treated with closed reductionand cast immobilization. If the fractures redisplaced treatedby percutaneous Kirschner (K- wire with scope undera general anaesthesia.Results: Totally 104 patients, who have distal radius fractureswere treated by closed reduction and immobilizationin a plaster cast. 13 patient who have distal radiusfractures were treated by closed reduction under generalanaesthesia and fixed by percutaneous Kirschner (K-wire. Patients with impaired the alignment of the fracturein late period were usually completely displaced fractures.(n=5, 4,3%, in early period, completely displaced fractures(n=5, 4,3% are superior to partial displaced fractures(n=2, 1,7%.Conclusion: In our study, when children with distal radiusfracture first come, they were treated by closed reductionand immobilization in a plaster cast. We thought that inredisplaced fractures patients were suitable for the closedreduction with percutaneous wire treatment.

  7. Fracture heuristics: surgical decision for approaches to distal radius fractures. A surgeon's perspective.

    Science.gov (United States)

    Wichlas, Florian; Tsitsilonis, Serafim; Kopf, Sebastian; Krapohl, Björn Dirk; Manegold, Sebastian

    2017-01-01

    Introduction: The aim of the present study is to develop a heuristic that could replace the surgeon's analysis for the decision on the operative approach of distal radius fractures based on simple fracture characteristics. Patients and methods: Five hundred distal radius fractures operated between 2011 and 2014 were analyzed for the surgeon's decision on the approach used. The 500 distal radius fractures were treated with open reduction and internal fixation through palmar, dorsal, and dorsopalmar approaches with 2.4 mm locking plates or underwent percutaneous fixation. The parameters that should replace the surgeon's analysis were the fractured palmar cortex, and the frontal and the sagittal split of the articular surface of the distal radius. Results: The palmar approach was used for 422 (84.4%) fractures, the dorsal approach for 39 (7.8%), and the combined dorsopalmar approach for 30 (6.0%). Nine (1.8%) fractures were treated percutaneously. The correlation between the fractured palmar cortex and the used palmar approach was moderate (r=0.464; p<0.0001). The correlation between the frontal split and the dorsal approach, including the dorsopalmar approach, was strong (r=0.715; p<0.0001). The sagittal split had only a weak correlation for the dorsal and dorsopalmar approach (r=0.300; p<0.0001). Discussion: The study shows that the surgical decision on the preferred approach is dictated through two simple factors, even in the case of complex fractures. Conclusion: When the palmar cortex is displaced in distal radius fractures, a palmar approach should be used. When there is a displaced frontal split of the articular surface, a dorsal approach should be used. When both are present, a dorsopalmar approach should be used. These two simple parameters could replace the surgeon's analysis for the surgical approach.

  8. Relationship between plate removal and Soong grading following surgery for fractured distal radius

    NARCIS (Netherlands)

    Selles, Caroline A.; Reerds, Sam T. H.; Roukema, Gert; van der Vlies, Kees H.; Cleffken, Berry I.; Schep, Niels W. L.

    2018-01-01

    The aim of this study was to determine the relationship between volar plate removal and the Soong classification following fixation for fractured distal radius. In this retrospective cohort study, all consecutive patients who had volar plate fixation for a distal radius fracture in 2011-2015 were

  9. Is Bone Grafting Necessary in the Treatment of Malunited Distal Radius Fractures?

    Science.gov (United States)

    Disseldorp, Dominique J. G.; Poeze, Martijn; Hannemann, Pascal F. W.; Brink, Peter R. G.

    2015-01-01

    Background Open wedge osteotomy with bone grafting and plate fixation is the standard procedure for the correction of malunited distal radius fractures. Bone grafts are used to increase structural stability and to enhance new bone formation. However, bone grafts are also associated with donor site morbidity, delayed union at bone–graft interfaces, size mismatch between graft and osteotomy defect, and additional operation time. Purpose The goal of this study was to assess bone healing and secondary fracture displacement in the treatment of malunited distal radius fractures without the use of bone grafting. Methods Between January 1993 and December 2013, 132 corrective osteotomies and plate fixations without bone grafting were performed for malunited distal radius fractures. The minimum follow-up time was 12 months. Primary study outcomes were time to complete bone healing and secondary fracture displacement. Preoperative and postoperative radiographs during follow-up were compared with each other, as well as with radiographs of the uninjured side. Results All 132 osteotomies healed. In two cases (1.5%), healing took more than 4 months, but reinterventions were not necessary. No cases of secondary fracture displacement or hardware failure were observed. Significant improvements in all radiographic parameters were shown after corrective osteotomy and plate fixation. Conclusion This study shows that bone grafts are not required for bone healing and prevention of secondary fracture displacement after corrective osteotomy and plate fixation of malunited distal radius fractures. Level of evidence Therapeutic, level IV, case series with no comparison group PMID:26261748

  10. [Distal radius fractures--retrospective quality control after conservative and operative therapy].

    Science.gov (United States)

    Sommer, C; Brendebach, L; Meier, R; Leutenegger, A

    2001-01-01

    The distal radius fracture is the most frequent fracture in the adult patient. The wide spectrum of different types of fracture and the coexisting factors make the choice for the optimal treatment difficult. As an interne quality control we retrospectively evaluated all patients with distal radius fractures treated in 1995 at our institution. The study included 69 adult patients with 71 distal radius fractures. After on average 26 months 58 patients with 59 fractures were clinically and radiologically evaluated. The patients were asked to give supplementary information about their follow-up treatment as well as any remaining physical difficulties and limitations in the daily life. All x-rays of the broken radius were carefully analysed and compared with the opposite side. The final results were evaluated according to the "Demerit Point System". Patients were treated with five different therapeutical methods. 76.3% of the patients showed a very good/good final result. In 56.7% of the cases secondary fracture dislocation occurred; the dislocation-rate of fractures treated with percutaneous k-wires was 93.3%! A clear correlation between secondary displacement and final results was found. A main factor for an optimal outcome is the anatomic restoration of length and axis of the distal radius as well as of joint congruency, also moderate angular deformities are well tolerated. Our collective showed an unexpected high rate of secondary displacement, especially in the k-wire group. The reasons for this unsatisfactory event are manifold: too optimistic indication, insufficient follow-up examination in the first four to six weeks, inconsequent change to a more stable fixation method in case of a secondary dislocation. The results of this retrospective evaluation had a major impact on our concept of treatment. The dorso-radial double-plate technique combined with bone graft will be more used in the future especially in younger patients. The new standardised concept is the

  11. CT virtual reality in the preoperative workup of malunited distal radius fractures: preliminary results

    International Nuclear Information System (INIS)

    Rieger, Michael; Gruber, Hannes; Jaschke, Werner R.; Gabl, Markus; Mallouhi, Ammar

    2005-01-01

    Our objective was to evaluate the usefulness of CT virtual preoperative planning in the surgical repositioning of malunited distal radius fracture. Eleven patients with malunited distal radius fracture underwent multislice CT of both wrists. A preoperative workup was performed in a virtual reality environment created from the CT data sets. Virtual planning comprised three main procedures, carrying out the virtual osteotomy of the radius, prediction of the final position of the distal radius after osteotomy and computer-assisted manufacturing of a repositioning device, which was later placed at the surgical osteotomy site to reposition objectively the distal radius fragment before fixation with the osteosynthesis. All patients tolerated the surgical procedure well. During surgery, the orthopedic surgeons were not required in any of the cases to alter the position of the distal radius that was determined by the repositioning device. At postoperative follow-up, the anatomic relationship of the distal radius was restored (radial inclination, 21.4 ; volar tilt, 10.3 ; ulnar variance, 0.5 mm). Clinically, a significant improvement of pronation (P=0.012), supination (P=0.01), flexion (P=0.001) and extension (P=0.006) was achieved. Pain decreased from 54 to 7 points. CT virtual reality is a valuable adjunct for the preoperative workup and surgical reposition of malunited distal radius fractures. (orig.)

  12. "Osteoporosis and orthopods" incidences of osteoporosis in distal radius fracture from low energy trauma.

    LENUS (Irish Health Repository)

    Bahari, Syah

    2007-07-01

    Fracture of the distal radius from low energy trauma is a common presentation to orthopaedic trauma services. This fragility type fracture is associated with underlying osteoporosis. Osteoporosis is a \\'silent disease\\' where fragility fracture is a common presentation. Orthopaedic surgeons may be the only physician that these patients encounter. We found a high percentage of female patients who sustained a fragility fracture of the distal radius have an underlying osteoporosis. Further management of osteoporosis is important to prevent future fragility fractures.

  13. Factors Associated with Infection Following Open Distal Radius Fractures

    OpenAIRE

    Glueck, Dane A.; Charoglu, Constantine P.; Lawton, Jeffrey N.

    2009-01-01

    Open fractures are often classified according to a system described by Gustilo and Anderson. However, this system was applied to open long bone factures, which may not predict the incidence of infection in open metaphyseal fractures of the upper extremity. Other studies have found that wound contamination and systemic illness were the best predictors of infections in open hand fractures. Our study assessed infection in open distal radius fractures and identifies factors that are associated wi...

  14. The correlation of initial radiographic characteristics of distal radius fractures and injuries of the triangular fibrocartilage complex.

    Science.gov (United States)

    Kasapinova, K; Kamiloski, V

    2016-06-01

    Our purpose was to determine the correlation of initial radiographic parameters of a distal radius fracture with an injury of the triangular fibrocartilage complex. In a prospective study, 85 patients with surgically treated distal radius fractures were included. Wrist arthroscopy was used to identify and classify triangular fibrocartilage complex lesions. The initial radial length and angulation, dorsal angulation, ulnar variance and distal radioulnar distance were measured. Wrist arthroscopy identified a triangular fibrocartilage complex lesion in 45 patients. Statistical analysis did not identify a correlation with any single radiographic parameter of the distal radius fractures with the associated triangular fibrocartilage complex injuries. The initial radiograph of a distal radius fracture does not predict a triangular fibrocartilage complex injury. III. © The Author(s) 2016.

  15. Mid-term functional outcome after the internal fixation of distal radius fractures

    Directory of Open Access Journals (Sweden)

    Phadnis Joideep

    2012-01-01

    Full Text Available Abstract Background Distal radius fracture is a common injury with a variety of operative and non-operative management options. There remains debate as to the optimal treatment for a given patient and fracture. Despite the popularity of volar locking plate fixation, there are few large cohort or long term follow up studies to justify this modality. Our aim was to report the functional outcome of a large number of patients at a significant follow up time after fixation of their distal radius with a volar locking plate. Methods 180 patients with 183 fractures and a mean age of 62.4 years were followed up retrospectively at a mean of 30 months (Standard deviation = 10.4. Functional assessment was performed using the Disabilities of the Arm, Shoulder and Hand (DASH and modified MAYO wrist scores. Statistical analysis was performed to identify possible variables affecting outcome and radiographs were assessed to determine time to fracture union. Results The median DASH score was 2.3 and median MAYO score was 90 for the whole group. Overall, 133 patients (74% had a good or excellent DASH and MAYO score. Statistical analysis showed that no specific variable including gender, age, fracture type, post-operative immobilisation or surgeon grade significantly affected outcome. Complications occurred in 27 patients (15% and in 11 patients were major (6%. Conclusion This single centre large population series demonstrates good to excellent results in the majority of patients after volar locking plate fixation of the distal radius, with complication rates comparable to other non-operative and operative treatment modalities. On this basis we recommend this mode of fixation for distal radius fractures requiting operative intervention.

  16. Radiographic diagnosis of scapholunate dissociation among intra-articular fractures of the distal radius: interobserver reliability

    NARCIS (Netherlands)

    Gradl, Gertraud; Neuhaus, Valentin; Fuchsberger, Thomas; Guitton, Thierry G.; Prommersberger, Karl-Josef; Ring, David; Wahegaonkar, Abhijeet L.; Shafritz, Adam B.; Garcia, Aida E.; Caputo, Andrew E.; Terrono, Andrew L.; Spoor, Andy B.; Eschler, Anica; Vochteloo, Anne J. H.; Beumer, Annechien; Barquet, Antonio; Kristan, Anze; van der Zwan, Arnard L.; Berner, Arne; Ilyas, Asif; Jubel, Axel; Sutker, Ben; Nolan, Betsy M.; Petrisor, Brad; Cross, Brian J.; Wills, Brian P. D.; Barreto, Camilo J. R.; Fernandes, Carlos H.; Swigart, Carrie; Zalavras, Charalampos; Goldfarb, Charles A.; Cassidy, Charles; Eaton, Charles; Wilson, Chris; Cheng, Christine J.; Wall, Christopher J.; Walsh, Christopher J.; Jones, Christopher M.; Garnavos, Christos; Klostermann, Cyrus; Kirkpatrick, D. Kay; Eygendaal, Denise; Verbeek, Diederik O. F.; Beeres, Frank J. P.; Thomas, George; Ponsen, Kornelis J.; van den Bekerom, Michel P. J.; Schep, Niels; Kloen, Peter; Haverlag, Robert

    2013-01-01

    To evaluate the reliability and accuracy of diagnosis of scapholunate dissociation (SLD) among AO type C (compression articular) fractures of the distal radius. A total of 217 surgeons evaluated 21 sets of radiographs with type C fractures of the distal radius for which the status of the

  17. HAEMATOMA BLOCK- AN EFFECTIVE ALTERNATIVE TO GENERAL ANAESTHESIA FOR REDUCTION OF DISTAL RADIUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Prabhati Rani Mishra

    2016-12-01

    Full Text Available BACKGROUND Most common fracture in elderly patients is distal radius fracture. The most common method of management is closed reduction and immobilisation. The aim of the study is to compare the analgesic effects of haematoma block and general anaesthesia for closed reduction of distal fracture of radius. MATERIALS AND METHODS A prospective randomised controlled study was carried out among 100 patients of age group between 15-70 years of either sex who had fracture distal radius between 2015-2016. The patients having multiple fractures, pathological fractures or suffering from any organic diseases were excluded from the study. After taking informed written consent, the patients were randomised into two equal groups. In group A, reduction of fracture was done following administration of IV propofol and in group B after infiltration with 2% lignocaine into fracture haematoma site. Pain score was compared by VAS before, during and after manipulation in both the groups. Time taken from presentation at emergency department to reduction and discharge from hospital was also compared. Statistical analysis was done by applying SPSS software. RESULTS 100 patients of mean age 42.5 years, male: female 43:57 with fracture distal radius were studied. Mean time from admission to fracture reduction in group A was 2.64±0.93 hours and in group B 0.90±0.45 hours (P=0.0001. Discharge time from hospital after reduction of fracture in group A was 4.24±0.94 hours and in group B 0.75±0.2 hours (P=0.0001. VAS during reduction in group A was 0 and in group B 0.98±0.8 (P=0.0001. 10 minutes after reduction VAS in group A was 2.28±0.24 and group B 0.72±0.45 (P=0.0001. CONCLUSION For closed reduction of distal radius fracture, haematoma block with lignocaine is safe and effective alternative to intravenous general anaesthesia with propofol.

  18. Two peg spade plate for distal radius fractures A novel technique

    Directory of Open Access Journals (Sweden)

    Sharad M Hardikar

    2015-01-01

    Conclusions: The two peg volar spade plate provides a stable subchondral support in comminuted intraarticular fractures and maintains reduction in osteoporotic fractures of the distal radius. Early mobilization with this implant helps in restoring wrist motion and to prevent development of wrist stiffness.

  19. Clinical effects of internal fixation for ulnar styloid fractures associated with distal radius fractures: A matched case-control study.

    Science.gov (United States)

    Sawada, Hideyoshi; Shinohara, Takaaki; Natsume, Tadahiro; Hirata, Hitoshi

    2016-11-01

    Ulnar styloid fractures are often associated with distal radius fractures. However, controversy exists regarding whether to treat ulnar styloid fractures. This study aimed to evaluate clinical effects of internal fixation for ulnar styloid fractures after distal radius fractures were treated with the volar locking plate system. We used prospectively collected data of distal radius fractures. 111 patients were enrolled in this study. A matched case-control study design was used. We selected patients who underwent fixation for ulnar styloid fractures (case group). Three control patients for each patient of the case group were matched on the basis of age, sex, and fracture type of distal radius fractures from among patients who did not undergo fixation for ulnar styloid fractures (control group). The case group included 16 patients (7 men, 9 women; mean age: 52.6 years; classification of ulnar styloid fractures: center, 3; base, 11; and proximal, 2). The control group included 48 patients (15 men, 33 women; mean age: 61.1 years; classification of ulnar styloid fractures: center, 10; base, 31; and proximal, 7). For radiographic examination, the volar tilt angle, radial inclination angle, and ulnar variance length were measured, and the union of ulnar styloid fractures was judged. For clinical examination, the range of motions, grip strength, Hand20 score, and Numeric Rating Scale score were evaluated. There was little correction loss for each radiological parameter of fracture reduction, and these parameters were not significantly different between the groups. The bone-healing rate of ulnar styloid fractures was significantly higher in the case group than in the control group, but the clinical results were not significantly different. We revealed that there was no need to fix ulnar styloid fractures when distal radius fractures were treated via open reduction and internal fixation with a volar locking plate system. Copyright © 2016 The Japanese Orthopaedic Association

  20. Pathologic fracture of the distal radius in a 25-year-old patient with a large unicameral bone cyst.

    Science.gov (United States)

    Massen, Felix; Baumbach, Sebastian; Volkmer, Elias; Mutschler, Wolf; Grote, Stefan

    2014-06-13

    Distal radius fractures (DRF) are often referred to as osteoporosis indicator fractures as their incidence increases from age 45. In the group of young adults, distal radius fractures normally result from high-energy trauma. Wrist fractures in young patients without adequate trauma thus raise suspicion of a pathologic fracture. In this report we present the case of a fractured unicameral bone cyst (UBC) at the distal radius in a young adult.To the author's best knowledge, this is the first detailed report in an UBC at the distal radius causing a pathologic DRF in an adult patient. A 25-year-old otherwise healthy male presented to our Emergency Department after a simple fall on his right outstretched hand. Extended diagnostics revealed a pathologic, dorsally displaced, intra-articular distal radius fracture secondary to a unicameral bone cyst occupying almost the whole metaphysis of the distal radius. To stabilize the fracture, a combined dorsal and volar approach was used for open reduction and internal fixation. A tissue specimen for histopathological examination was gathered and the lesion was filled with an autologous bone graft harvested from the ipsilateral femur using a reamer-irrigator-aspirator (RIA) system. Following one revision surgery due to an intra-articular step-off, the patient recovered without further complications. Pathologic fractures in young patients caused by unicameral bone cysts require extended diagnostics and adequate treatment. A single step surgical treatment is reasonable if fracture and bone cyst are treated appropriately. Arthroscopically assisted fracture repair may be considered in intra-articular fractures or whenever co-pathologies of the carpus are suspected.

  1. The reliability of AO classification for distal radius fracture, using CT findings

    International Nuclear Information System (INIS)

    Nakanishi, Yasuaki; Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryoutarou; Ota, Hiroyoshi

    2006-01-01

    The purpose of this study was to assess the reliability of the AO (Association for the Study of Internal Fixation) classification of distal radius fracture, using plain radiographs and 2 cross-sectional computed tomographic (CT) surface images. Five observers independently classified 32 distal radius fractures into 9 groups under AO classification. We established 4 methods for observation. First, using only two-directional radiographs; second, four-directional radiographs; third, CT (axial view) with four-directional radiographs; and fourth, CT (axial and sagittal views) with four-directional radiographs. Kappa statistics were used to establish the relative level of agreement between the observers. Interobserver reliability was poor in both first and second methods in which only plain radiographs were used (κ=0.30 and 0.23, respectively). Furthermore, reliability did not increase in the third method with the addition of 1 CT surface image (κ=0.29). In the fourth method, with the addition of 2 cross-sectional CT surface images, the reliability increased to a moderate level (κ=0.44). Interobserver reliability of the AO system of the classification of distal radius fractures was observed on using 2 cross-sectional CT surface images with four-directional radiographs. (author)

  2. A COMPARATIVE STUDY OF CONSERVATIVE MANAGEMENT VS. EXTERNAL FIXATION OF COMMINUTED DISTAL RADIUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Sanjeev Kumar Kare

    2016-12-01

    Full Text Available BACKGROUND Fracture of the distal radius (‘broken wrist’ is a common clinical problem. It can be treated conservatively usually involving wrist immobilisation in a plaster cast or surgically. A key method of surgical fixation is external fixation. MATERIALS AND METHODS A prospective study was carried out on 66 patients admitted between June 2014 to May 2016 for evaluation of conservative and surgical management of distal radius fractures. RESULTS Excellent, fair or good result was noticed in around 85% of cases managed conservatively and in above 90% of cases managed by external fixator. CONCLUSION There is some evidence to support the use of external fixation for dorsally displaced fractures of the distal radius in adults. Though, there is insufficient evidence to confirm a better functional outcome, external fixation reduces redisplacement gives improved anatomical results and most of the excess surgically-related complications are minor.

  3. Classification and treatment of distal radius fractures: a survey among orthopaedic trauma surgeons and residents

    NARCIS (Netherlands)

    M.A.M. Mulders (Marjolein A. M.); D. Rikli; J.C. Goslings (Carel); N.W.L. Schep (Niels)

    2017-01-01

    textabstractPurpose: Classification, the definition of an acceptable reduction and indications for surgery in distal radius fracturemanagement are still subject of debate. The purpose of this study was to characterise current distal radius fracture management in Europe. Methods: During the European

  4. Osteosynthesis with long volar locking plates for meta- physeal-diaphyseal fractures of the distal radius

    Directory of Open Access Journals (Sweden)

    Gogna Paritosh

    2013-12-01

    Full Text Available 【Abstract】Objective: Metaphyseal-diaphyseal fractures of the distal radius are a major treatment dilemma and orthopaedic surgeons have to pay due consideration to restoration of anatomy of distal radius together with ro- tation of the radial shaft and maintenance of radial bow and interosseous space. We performed this study to evaluate the clinic-radiological outcome of metaphyseal-diaphyseal fractures of the distal radius treated with long volar locking plates. Methods: This prospective study involved 27 pa- tients (22 males and 5 females with metaphyseal-diaphy- seal fracture of the distal radius. Their mean age was (30.12± 11.48 years (range 19-52 years and the follow-up was 26.8 months (range 22-34 months. All patients underwent open reduction and internal fixation with a long volar locking plate. According to AO/OTA classification, there were 7 type A3, 13 type C2 and 7 type C3 fractures. Subjective assessment was done based on the disabilities of the arm, shoulder and hand (DASH questionnaire. Functional evaluation was done by measuring grip strength and range of motion around the wrist and the radiological determinants included radial angle, radial length, volar angle and ulnar variance. The final as- sessment was done according to Gartland and Werley scor- ing system. Results: Postoperative radiological parameters were well maintained throughout the trial, and there was signifi- cant improvement in the functional parameters from 6 weeks to final follow-up. The average DASH scores improved from 37.5 at 6 weeks to 4.2 at final follow-up. Final assessment using Gartland and Werley scoring system revealed 66.67% (n=18 excellent and 33.33% (n=9 good results. There was one case of superficial infection which responded to antibi- otics and another carpel tunnel syndrome which was ma- naged conservatively. Conclusion: Volar locking plate fixation for metaphy- seal-diaphyseal fractures of distal radius is associated with excellent to good

  5. [APPLICATION OF BUTTERFLY SHAPED LOCKING COMPRESSION PLATE IN COMPLEX DISTAL RADIUS FRACTURES].

    Science.gov (United States)

    Jiang, Zongyuan; Ma, Tao; Xia, Jiang; Hu, Caizhi; Xu, Lei

    2014-06-01

    To investigate the effectiveness of butterfly shaped locking compression plate for the treatment of complex distal radius fractures. Between June 2011 and January 2013, 20 cases of complex distal radius fractures were treated with butterfly shaped locking compression plate fixation. There were 11 males and 9 females with an average age of 54 years (range, 25-75 years). Injury was caused by falling in 10 cases, by traffic accident in 7 cases, and by falling from height in 3 cases. All of fractures were closed. According to AO classification system, there were 8 cases of type C1, 8 cases of type C2, and 4 cases of type C3. Of them, 9 cases had radial styloid process fracture, 4 cases had sigmoid notch fracture, and 7 cases had both radial styloid process fracture and sigmoid notch fracture. The mean interval between injury and operation was 5.2 days (range, 3-15 days). All incisions healed by first intention; no complications of infection and necrosis occurred. All cases were followed up 14 months on average (range, 10-22 months). All factures healed after 9.3 weeks on average (range, 6-11 weeks). No complications such as displacement of fracture, joint surface subsidence, shortening of the radius, and carpal tunnel syndrome were found during follow-up. At last follow-up, the mean palmar tilt angle was 10.2° (range, 7-15°), and the mean ulnar deviation angle was 21.8° (range, 17-24°). The mean range of motion of the wrist was 45.3° (range, 35-68°) in dorsal extension, 53.5° (range, 40-78°) in palmar flexion, 19.8° (range, 12-27°) in radial inclination, 26.6° (range, 18-31°) in ulnar inclination, 70.2° (range, 45-90°) in pronation, and 68.4° (range, 25-88°) in supination. According to the Dienst scoring system, the results were excellent in 8 cases, good in 10 cases, and fair in 2 cases, and the excellent and good rate was 90%. Treatment of complex distal radius fractures with butterfly shaped locking compression plate can reconstruct normal anatomic

  6. Treatment of unstable distal radius fractures with Ilizarov circular, nonbridging external fixator.

    Science.gov (United States)

    Tyllianakis, Minos; Mylonas, Spyros; Saridis, Alkis; Kallivokas, Alkiviadis; Kouzelis, Antonis; Megas, Panagiotis

    2010-03-01

    Unstable distal radius fractures remain a challenge for the treating orthopaedic surgeon. We present a retrospective follow-up study (mean follow-up 12.5 months) of 20 patients with 21 unstable distal radius fractures that were reduced in a closed manner and stabilized with a nonbridging Ilizarov external fixator. Subsequent insertion of olive wires for interfragmentary compression was performed in cases with intra-articular fractures. According to the overall evaluation proposed by Gartland and Werley scoring system 12 wrists were classified as excellent, 6 as good, 2 as fair and 1 as poor. Grade II pin-tract infection in distal fracture fragment was detected in 3 wires from a total of 78 (3.8%) and in 4 half pins out of a total of 9 (44.4%). Pronation was the most frequently impaired movement. This was restricted in 4 patients (19%) in whom a radioulnar transfixing wire was applied. Symptoms of irritation of superficial sensory branch of the radial nerve occurred in 3 patients with an olive wire applied in a closed manner in the distal fragment. Ilizarov method yields functional results comparable to that of other methods whilst it avoids wrist immobilization, open reduction and reoperation for implant removal. The method is associated with a low rate of major complication and satisfactory functional outcome. Copyright 2009 Elsevier Ltd. All rights reserved.

  7. Radiographic Outcomes of Dorsal Distraction Distal Radius Plating for Fractures With Dorsal Marginal Impaction.

    Science.gov (United States)

    Huish, Eric G; Coury, John G; Ibrahim, Mohamed A; Trzeciak, Marc A

    2017-04-01

    The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results with prior publications for both external fixation and internal fixation with volar locked plates. Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (M.A.T. and M.A.I.) from May 30, 2013, to December 29, 2015, were identified and included in the study. Retrospective chart and radiograph review was performed on 19 patients, 11 male and 8 female, with mean age of 47.83 years (22-82). No patients were excluded from the study. All fractures united prior to plate removal. The average time the plate was in place was 80.5 days (49-129). Follow-up radiographs showed average radial inclination of 20.5° (13.2°-25.5°), radial height of 10.7 mm (7.5-14 mm), ulnar variance of -0.3 mm (-2.1 to 3.1 mm), and volar tilt of 7.9° (-3° to 15°). One patient had intra-articular step-off greater than 2 mm. Dorsal distraction plating of complex distal radius fractures yields good radiographic results with minimal complications. In cases of complex distal radius fractures including dorsal marginal impaction where volar plating is not considered adequate, a dorsal distraction plate should be considered as an alternative to external fixation due to reduced risk for infection and better control of volar tilt.

  8. A PROSPECTIVE STUDY OF CLINICAL OUTCOME AFTER USING LIGAMENTOTAXIS IN MANAGEMENT OF DISTAL RADIUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Chandrashekhar V. Mudgal

    2017-04-01

    Full Text Available BACKGROUND A study was done to evaluate the effect of the ligamentotaxis in the management of intraarticular fractures of the distal radius. MATERIALS AND METHODS 34 patients were studied prospectively between March 2014 and February 2016. All patients had intraarticular fracture of distal end of radius and all were treated with ligamentotaxis after closed reduction with fluoroscopic guidance. The follow-up period was 12 months. At the time of surgery, the mean age was 45.29 years. RESULTS In all fracture cases, the mean of fracture union was 5.8 weeks. During the final follow-up, the mean range of motion was 55.30 in flexion, 56.60 in extension, 21.0 in ulnar deviation, 9.00 in radial deviation, 70.30 in pronation and 67.10 in supination. According to the scoring system of Gartland and Werley, the clinical and functional outcomes showed that 15 patients (44.1% had excellent results, 14 (41.1% had good results, 3 (8.8% had fair results and 2 (5.8% had poor results. CONCLUSION Closed reduction under fluoroscopic image guidance and the ligamentotaxis is useful and effective in the treatment of intraarticular fractures of the distal radius.

  9. Clinical and functional outcome of open primary repair of triangular fibrocartilage complex tears associated with distal radius fractures.

    Science.gov (United States)

    Johandi, Faisal; Sechachalam, Sreedharan

    2017-01-01

    We evaluate the clinical and functional outcome of open primary repair of acute TFCC tears in distal radius fracture, when there is gross intraoperative distal radioulnar joint (DRUJ) instability after fixation of the distal radius, in the absence of an ulnar styloid fracture or when the ulnar fracture fragment is too small to be fixed. A retrospective review of our institution's distal radius fracture database over a 4-year period (January 2010 to December 2013). A total of 12 (1.38%) out of 3379 patients had an open TFCC repair in the same setting as fixation of distal radius. Assessment of outcome involved the analysis of objective and subjective clinical and functional outcomes. All patient regained Activities of Daily Living (ADL) independence; eleven out of 12 patients (91.7%) returned to pre-injury function and 8 out of 11 patients (72.7%) returned to their jobs. DRUJ stability was preserved in 10 patients (83.3%) with 10 patients (83.3%) having grip strength of at least 50%, compared to the uninjured hand, and 7 (58.3%) with grip strength of more than or equal to 75%. Complications of surgery identified can be classified into 4 broad categories: infection, neurological complications, persistent DRUJ instability and prolonged pain. The authors believe a primary open repair of the TFCC should be considered when patients present with instability during intra-operative DRUJ ballottement test after distal radius fixation, in the absence of an ulnar styloid fracture or when the ulnar fracture fragment is too small to be fixed.

  10. Treatment of unstable intraarticular fracture of distal radius: POP casting with external fixation.

    Science.gov (United States)

    ur Rahman, Obaid; Khan, Mohammad Qadeem; Rasheed, Haroon; Ahmad, Saleem

    2012-04-01

    To compare radiological and functional outcome of external fixation and distraction with conservative Plaster of Paris (POP) cast for unstable intra-articular fractures of the distal radius. The study was conducted on 60 patients with unstable intra-articular fracture of distal radius who reported to emergency or outpatient Orthopaedic Surgery department of Benazir Bhutto Hospital, Rawalpindi, between March and August 2007. They were divided into two equal groups: Group A and Group B, treated by Plaster of Paris cast, and external fixation with distraction respectively. The functional outcome in terms of freedom from pain, range of movement, grip power and deformity, and the radiological outcome of radial length, incongruity and radio-ulnar joint position were analysed at three months follow-up using a 3-point scoring scale. In Group A, 1 (3%) patient showed excellent result, 8 (27%) patients good results, 19 (63%) patients fair results and 2 (7%) patients poor result. In Group B, 14 (47%) patients showed excellent results, 11 (37%) patients good results, 4 (13%) patients fair results and 1 (3%) patient poor result. The outcome score of the Group B patients was significantly better compared to the Group A patients (p value advantages over conventional Plaster of Paris cast in the treatment of unstable intra-articular fractures of distal radius.

  11. A new building block: costo-osteochondral graft for intra-articular incongruity after distal radius fracture.

    Science.gov (United States)

    Tang, Chris Yuk Kwan; Fung, Boris; Poon, T L; Fok, Margaret

    2014-01-01

    Even with the invention of locking plates, intra-articular fractures of distal radius with extreme comminution remain a challenge for orthopaedic surgeons. Osteochondral graft is a potential choice to reconstruct the articular defect. We report a patient who had a fracture of distal radius with costo-osteochondral graft for articular reconstruction which has not yet been described in the English literature. At nine-year follow-up, he was pain free and had full range of movement of the wrist. The authors suggest that costo-osteochondral graft could be an option with satisfactory result.

  12. Analysis of the Arthroscopically Diagnosed Soft-Tissue Injuries Associated With the Distal Radius Fractures

    Directory of Open Access Journals (Sweden)

    Katerina Katerina Kasapinova

    2014-06-01

    CONCLUSIONS: The frequency of the associated soft-tissue lesions in distal radius fractures is high. Ulnar styloid fracture was identified as risk factor for associated LT lesion, as well as combined lesion of both scapholunate and luntriquetral ligament.

  13. The effect of search term on the quality and accuracy of online information regarding distal radius fractures.

    Science.gov (United States)

    Dy, Christopher J; Taylor, Samuel A; Patel, Ronak M; Kitay, Alison; Roberts, Timothy R; Daluiski, Aaron

    2012-09-01

    Recent emphasis on shared decision making and patient-centered research has increased the importance of patient education and health literacy. The internet is rapidly growing as a source of self-education for patients. However, concern exists over the quality, accuracy, and readability of the information. Our objective was to determine whether the quality, accuracy, and readability of information online about distal radius fractures vary with the search term. This was a prospective evaluation of 3 search engines using 3 different search terms of varying sophistication ("distal radius fracture," "wrist fracture," and "broken wrist"). We evaluated 70 unique Web sites for quality, accuracy, and readability. We used comparative statistics to determine whether the search term affected the quality, accuracy, and readability of the Web sites found. Three orthopedic surgeons independently gauged quality and accuracy of information using a set of predetermined scoring criteria. We evaluated the readability of the Web site using the Fleisch-Kincaid score for reading grade level. There were significant differences in the quality, accuracy, and readability of information found, depending on the search term. We found higher quality and accuracy resulted from the search term "distal radius fracture," particularly compared with Web sites resulting from the term "broken wrist." The reading level was higher than recommended in 65 of the 70 Web sites and was significantly higher when searching with "distal radius fracture" than "wrist fracture" or "broken wrist." There was no correlation between Web site reading level and quality or accuracy. The readability of information about distal radius fractures in most Web sites was higher than the recommended reading level for the general public. The quality and accuracy of the information found significantly varied with the sophistication of the search term used. Physicians, professional societies, and search engines should consider

  14. Reliability of radiographic measurements for acute distal radius fractures

    International Nuclear Information System (INIS)

    Watson, Narelle J.; Asadollahi, Saeed; Parrish, Frank; Ridgway, Jacqueline; Tran, Phong; Keating, Jennifer L.

    2016-01-01

    The management of distal radial fractures is guided by the interpretation of radiographic findings. The aim of this investigation was to determine the intra- and inter-observer reliability of eight traditionally reported anatomic radiographic parameters in adults with an acute distal radius fracture. Five observers participated. All were routinely involved in making treatment decisions based on distal radius fracture radiographs. Observers performed independent repeated measurements on 30 radiographs for eight anatomical parameters: dorsal shift (mm), intra-articular gap (mm), intra-articular step (mm), palmar tilt (degrees), radial angle (degrees), radial height (mm), radial shift (mm), ulnar variance (mm). Intraclass correlation coefficients (ICCs) and the magnitude of retest errors were calculated. Measurement reliability was summarised as high (ICC > 0.80), moderate (0.60–0.80) or low (<0.60). Intra-observer reliability was high for dorsal shift and palmar tilt; moderate for radial angle, radial height, ulnar variance and radial shift; and low for intra-articular gap and step. Inter-observer reliability was high for palmar tilt; moderate for dorsal shift, ulnar variance, radial angle and radial height; and low for radial shift, intra-articular gap and step. Error magnitude (95 % confidence interval) was within 1–2 mm for intra-articular gap and step, 2–4 mm for ulnar variance, 4–6 mm for radial shift, dorsal shift and radial height, and 6–8° for radial angle and palmar tilt. Based on previous reports of critical values for palmar tilt, ulnar variance and radial angle, error margins appear small enough for measurements to be useful in guiding treatment decisions. Our findings indicate that clinicians cannot reliably measure values ≤1 mm for intra-articular gap and step when interpreting radiographic parameters using the standardised methods investigated in this study. As a guide for treatment selection, palmar tilt, ulnar variance and radial angle

  15. Distal radius fractures result in alterations in scapular kinematics: a three-dimensional motion analysis.

    Science.gov (United States)

    Ayhan, Cigdem; Turgut, Elif; Baltaci, Gul

    2015-03-01

    Scapular motion is closely integrated with arm motion. Injury to a distal segment requires compensatory changes in the proximal segments leading to alterations in scapular motion. Since the effects of distal injuries on scapular kinematics remain unknown, in the present study we investigated the influences on scapular motion in patients with distal injuries. Sixteen subjects with a history of distal radius fracture and 20 asymptomatic healthy subjects (controls) participated in the study. Three-dimensional scapular and humeral kinematic data were collected on all 3 planes of shoulder elevation: frontal, sagittal, and scapular. All testing was performed in a single session; therefore, the sensors remained attached to the participants for all testing. The position and orientation data of the scapula at 30°, 60°, 90°, and 120° humerothoracic elevation and 120°, 90°, 60°, and 30° lowering were used for statistical comparisons. Independent samples t-test was used to compare the scapular internal/external rotation, upward/downward rotation, and anterior/posterior tilt between the affected side of subjects with a distal radius fracture and the dominant side of asymptomatic subjects at the same stage of humerothoracic elevation. Scapular internal rotation was significantly increased at 30° elevation (P=0.01), 90° elevation (P=0.03), and 30° lowering (P=0.03), and upward rotation was increased at 30° and 60° elevation (Pplane elevation. Scapular upward rotation and anterior tilt were significantly increased during 30° lowering on both the scapular (P=0.002 and 0.02, respectively) and sagittal planes (P=0.01 and 0.02. respectively). Patients with distal radius fractures exhibit altered scapular kinematics, which may further contribute to the development of secondary musculoskeletal pathologies. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Patterns of triangular fibrocartilage complex (TFCC) injury associated with severely dorsally displaced extra-articular distal radius fractures.

    Science.gov (United States)

    Scheer, Johan H; Adolfsson, Lars E

    2012-06-01

    The aim of the study was to examine triangular fibrocartilage (TFCC) injury patterns associated with unstable, extra-articular dorsally displaced distal radius fractures. Twenty adult patients with an Arbeitsgemeinschaft für Osteosynthesefragen (AO), type A2 or A3, distal radius fracture with an initial dorsal angulation greater than 20° were included. Nine had a tip fracture (distal to the base) of the ulnar styloid and 11 had no such fracture. They were all openly explored from an ulnopalmar approach and TFCC injuries were documented. Eleven patients also underwent arthroscopy and intra-articular pathology was recorded. All patients had TFCC lesions of varying severity, having an extensor carpi ulnaris subsheath avulsion in common. Eighteen out of 20 also displayed deep foveal radioulnar ligament lesions, with decreasingly dorsal fibres remaining. The extent of this foveal injury could not be appreciated by radiocarpal arthroscopy. Severe displacement of an extra-articular radius fracture suggests an ulnar-sided ligament injury to the TFCC. The observed lesions concur with findings in a previous cadaver study. The lesions follow a distinct pattern affecting both radioulnar as well as ulnocarpal stabilisers. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. [Injury to the Scapholunate Ligament in Distal Radius Fractures: Peri-Operative Diagnosis and Treatment Results].

    Science.gov (United States)

    Gajdoš, R; Pilný, J; Pokorná, A

    2016-01-01

    PURPOSE OF THE STUDY Injury to the scapholunate ligament is frequently associated with a fracture of the distal radius. At present neither a unified concept of treatment nor a standard method of diagnosis in these concomitant injuries is available. The aim of the study was to evaluate a group of surgically treated patients with distal radius fractures in order to assess a contribution of combined conventional X-ray and intra-operative fluoroscopic examinations to the diagnosis of associated lesions and to compare short-term functional outcomes of sugically treated patients with those of patients treated conservatively. MATERIAL AND METHODS A group of patients undergoiong surgery for distal radius fractures using plate osteosynthesis was evaluated retrospectively. The peri-operative diagnosis of associated injury to the scapholunate ligament was based on pre-operative standard X-ray views and intra-operative fluoroscopy. The latter consisted of images of maximum radial and ulnar deviation as well as an image of the forearm in traction exerted manually along the long axis. All views were in postero-anterior projection. Results were read directly on the monitor of a fluoroscopic device after its calibration or were obtained by comparing the thickness of an attached Kirschner wire with the distance to be measured. Subsequently, pixels were converted to millimetres. When a scapholunate ligament injury was found and confirmed by examination of the contralateral wrist, the finding was verified by open reduction or arthroscopy. Both static and dynamic instabilities were treated together with the distal radius fracture at one-stage surgery. After surgery, the patients without ligament injury had the wrist immobilised for 4 weeks, then rehabilitation followed. In the patients with a damaged ligament, immobilisation in a short brace lasted until transarticular wires were removed. All patients were followed up for a year at least. At follow-up, the injured wrist was examined

  18. [Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    Science.gov (United States)

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2017-11-07

    Objective: To make a systematic assessment of the Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Methods: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed. The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected. The included trials were screened out strictly based on the criterion of inclusion and exclusion. The quality of included trials was evaluated. RevMan 5.0 was used for data analysis. Results: Sixteen studies involving 1 268 patients were included. There were 618 patients with open reduction and internal fixation and 650 with external fixation. The results of meta-analysis indicated that there were statistically significant differences with regard to the complications postoperatively (infection( I (2)=0%, RR =0.27, 95% CI 0.16-0.45, Z =4.92, P internal fixation and external fixation are effective treatment for unstable distal radius fractures. Compared with external fixation, open reduction and internal fixation provides reduced complications postoperatively, lower DASH scores and better restoration of volar tilt for treatment of distal radius fractures.

  19. Arthroscopic knotless anchor repair of triangular fibrocartilage in distal radius fracture.

    Science.gov (United States)

    García-Ruano, Á A; Najarro-Cid, F; Jiménez-Martín, A; Gómez de los Infantes-Troncoso, J G; Sicre-González, M

    2015-01-01

    Lesions of triangular fibrocartilage (TFC) are associated with distal radioulnar joint instability. Arthroscopic treatment of these lesions improves functional outcome of affected patients. The aim of the present work is to evaluate functional and occupational outcome of TCF repair using an arthroscopic knotless anchor device in patients with associated distal radius fracture. An observational, descriptive study was carried out between November 2011 and January 2014 including 21 patients with distal radius fracture and Palmer 1B lesions of TCF (Atzei class 2 and 3) that were treated by arthroscopic knotless anchor (PopLok® 2,8mm, ConMed, USA). Mean follow-up was 18 months. Functional (Mayo Wrist Score) and occupational outcome results were analyzed. Mean age of the group was 43.0±8.8 years, with 19% of the patients being female. There was an associated scapholunate lesion in 5 cases. Functional results reached a mean of 83.4±16.1 points onMayo Wrist Score. Mean sick-leave time was 153.16±48.5 days. Complete occupational reintegration was reached in 89.5% of cases. There were no postoperative complications. Arthroscopic knotless anchor repair of 1B TFC tears is a minimally invasive method of treatment that improves tension of fixation, avoiding subsequent loosen, in our experience, with few complications and good functional and occupational results. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  20. A STUDY ON FRACTURE FIXATION OF DISTAL END OF RADIUS BY PERCUTANEOUS PINNING

    Directory of Open Access Journals (Sweden)

    Kiran Kumar L

    2016-07-01

    Full Text Available BACKGROUND Various treatment modalities have been described for the treatment of distal radius fractures each with its own merits and demerits. Most of the work done with percutaneous pinning has shown a significant residual stiffness of the hand and wrist. Our technique involves percutaneous pinning of the fracture and immobilisation in neutral position of the wrist for. This study's aim was to examine the functional outcome of percutaneous K-wiring of these distal radius fractures with immobilisation in neutral position of the wrist. METHODS A prospective study conducted on thirty adult patients with distal radial fractures treated at Department of Orthopaedics, Rangaraya Medical college, Kakinada between October 2013 to September 2015. RADIOGRAPHIC EXAMINATION Standard radiographs in PA and lateral views were taken for confirmation of the diagnosis and also to know the type of fracture. Oblique views were also taken in a few patients who had complex comminuted fractures. The fracture fragments were analysed and involvement of radiocarpal and distal radioulnar joints were assessed and classified according to the Frykman classification. Of the cases, 6(20% of the fractures were type I, 2(6.6% of type II, 3(10% of type III, 6(20% of type IV, 8(26.6% of type V, 5(16.6% of type VI, no cases of type VII and VIII.SURGICAL PROCEDURE The procedures were performed under regional anaesthesia in all cases. After sterile preparation and draping, fracture is reduced by traction and the reduction was evaluated fluoroscopically. A 1.5 cm incision given longitudinally (if needed beginning at the radial styloid and proceeds proximally across to the medial metaphysis and diaphysis. At least two pins (1.6 mm Kirschner wire were inserted and adequate reduction was confirmed on AP/LAT views under image intensifier. Another 1.6 mm K-wire percutaneously 90 degrees orthogonally to these wires starting at the dorsal rim of distal radius just distal to the Lister

  1. Assessment of "YouTube" Content for Distal Radius Fracture Immobilization.

    Science.gov (United States)

    Addar, Abdullah; Marwan, Yousef; Algarni, Nizar; Berry, Gregory

    Distal radius fractures (DRFs) are the most common orthopedic fractures, with >70% of cases treated by closed immobilization using a short arm cast or a sugar tong splint. However, inadequate immobilization is a risk factor for loss of reduction requiring repeat reduction or surgical treatment. Therefore, education of clinical skills for appropriate immobilization of DRFs is important. With the increasing use of web-based information by medical learners, our aim was to assess the quality and quantity of videos regarding closed immobilization of DRFs on YouTube. Retrospective review of YouTube videos on distal radius fracture immobilization using specific search terms. Identified videos were analyzed for their educational value, quality of the technical skill demonstrated, and overall metrics. Educational value was scored on a 5-point scale, with "1" indicative of low quality and "5" of high quality. Not applicable. Among the 68,366 videos identified, 16 met our inclusion criteria of being in English; performed by a health care professional or institution; and with casting being the major theme of the educational information provided. Of these 16 videos, 6 had an educational value score of 4 or 5, with the remaining 10 having a score ≤3. Although immobilization was demonstrated by cast technician specialized in orthopedics, skills were also performed by orthopedic attendants, urgent care physicians, orthopedic residents, and nurse practitioners. The credentials of the performer in 3 videos were not identified. There is a need to promote high-quality educational videos produced by established medical school faculty members on open, web-based, portals. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  2. Peak incidence of distal radius fractures due to ice skating on natural ice in The Netherlands

    NARCIS (Netherlands)

    van Lieshout, Arno P. W.; van Manen, Christiaan J.; du Pré, Karel J.; Kleinlugtenbelt, Ydo V.; Poolman, Rudolf W.; Goslings, J. Carel; Kloen, Peter

    2010-01-01

    An increase of distal radius fractures was seen in 2009 when an extended cold spell allowed natural ice skating in Amsterdam. This resulted in overload of our Emergency Departments and operating rooms. This study reports patient and fracture characteristics of these injuries. We also determined

  3. [Treatment type C fracture of the distal radius with locking compression plate and external fixators].

    Science.gov (United States)

    Yang, Xiang; Zhao, You-ming; Chen, Lin; Ye, Cong-cong; Guo, Wei-jun; Wang, Bo

    2013-12-01

    To compare efficacy of unilateral external fixators and locking compression plates in treating type C fractures of the distal radius. From January 2009 to June 2010, 76 patients with distal radius fracture were treated with LCP and external fixators, 54 patients were followed up. Among them, 29 cases were male and 25 cases were female with an average age of 45.31 (ranged, 24 to 68) years old. There were 29 patients in LCP group. According to AO classification, 8 cases were type C1, 7 cases were type C2 and 14 cases were type C3. There were 25 cases in external fixators group. According to AO classification, 6 cases were type C1, 8 cases were type C2 and 11 cases were type C3. Radial height, volar tilt and radial inclination were compared, advanced Gartland-Werley scoring were used to assessed wrist joint function after 6 and 12 months' following up. Two cases were suffered from nail infection in external fixators group. Fifty-four patients were followed up from 12 to 24 months with an average of 21.3 months. Radial height was (9.60 +/- 0.72) mm, volar tilt was (9.55 +/- 0.80) degrees and radial inclination was (21.40 +/- 0.78) degrees in LCP group,while those were (9.40 +/- 0.70) mm, (9.47 +/- 0.71) degrees and (21.20 +/- 0.73) degrees in external fixtors group, and with no statistical significance (P>0.05). Advanced Gartland-Werley score after 6 months' following up was 3.31 +/- 1.17 in LCP group, 5.56 +/- 1.58 in external fixtors group, and with significant difference (t=-5.99,Pmeaning (t=-1.55, P>0.05). LCP and external fixtors can receive good curative effects in treating type C distal radius fracture, and LCP can obtain obviously short-term efficacy, while there is no significant difference between two groups in long-term results. For serious distal radius comminuted fracture which unable to plate internal fixation, external fixators is a better choice.

  4. Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures.

    Science.gov (United States)

    Han, L R; Jin, C X; Yan, J; Han, S Z; He, X B; Yang, X F

    2015-03-31

    This study compared the efficacy between external fixator combined with palmar T-plate internal fixation and simple plate internal fixation for the treatment of comminuted distal radius fractures. A total of 61 patients classified as type C according to the AO/ASIF classification underwent surgery for comminuted distal radius fractures. There were 54 and 7 cases of closed and open fractures, respectively. Moreover, 19 patients received an external fixator combined with T-plate internal fixation, and 42 received simple plate internal fixation. All patients were treated successfully during 12-month postoperative follow-up. The follow-up results show that the palmar flexion and dorsiflexion of the wrist, radial height, and palmar angle were significantly better in those treated with the external fixator combined with T-plate compared to those treated with the simple plate only (P 0.05). Hence, the effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures was satisfactory. Patients sufficiently recovered wrist, forearm, and hand function. In conclusion, compared to the simple T-plate, the external fixator combined with T-plate internal fixation can reduce the possibility of the postoperative re-shifting of broken bones and keep the distraction of fractures to maintain radial height and prevent radial shortening.

  5. Does formal education and training of staff reduce the operation rate for fractures of the distal radius?

    Science.gov (United States)

    McDonald, Kyle; Murphy, Lynn; Gallagher, Brendan; Eames, Niall

    2013-12-01

    Fractures of the distal radius are one of the most common extremity fractures, and operation rates are increasing. Staff within our unit felt that formal teaching, particularly of new medical staff, with regards to fracture reduction and appropriate cast application could result in a reduction in operation rates. Retrospective data was extracted from FORD (Fracture Outcome and Research Database), including: number of fractures, number of fractures undergoing ORIF, fracture configuration, patient demographics, and mechanism of injury. All patients undergoing ORIF had their radiographs assessed by two separate reviewers. Information regarding adequate fracture reduction, adequate cast application (using Gap Index), and appropriate plaster cast moulding was recorded. Formal teaching was then given to the next group of medical staff rotating through the unit, and the same data was collected prospectively for that six-month period. Exclusion criteria included bilateral injuries, and polytrauma patients. A total of 1623 distal radial fractures were treated in our unit over the 12-month period, with 71 undergoing ORIF in the first 6 months and 39 in the second 6 months, this was statistically significant (p = 0.0009). Our study found that formal teaching and education significantly reduced the operation rate for distal radial fractures. This effect was most significant for extra-articular, dorsally angulated fractures of the distal radius. Our study proves that just 1 h of basic training at the beginning of an attachment can have significant benefits to both the unit and, more importantly, the patients. Copyright © 2013 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  6. Accuracy of specimen-specific nonlinear finite element analysis for evaluation of distal radius strength in cadaver material.

    Science.gov (United States)

    Matsuura, Yusuke; Kuniyoshi, Kazuki; Suzuki, Takane; Ogawa, Yasufumi; Sukegawa, Koji; Rokkaku, Tomoyuki; Takahashi, Kazuhisa

    2014-11-01

    Distal radius fracture, which often occurs in the setting of osteoporosis, can lead to permanent deformity and disability. Great effort has been directed toward developing noninvasive methods for evaluating the distal radius strength, with the goal of assessing fracture risk. The aim of this study was to evaluate distal radius strength using a finite element model and to gauge the accuracy of finite element model measurement using cadaver material. Ten wrists were obtained from cadavers with a mean age of 89.5 years at death. CT images of each wrist in an extended position were obtained. CT-based finite element models were prepared with Mechanical Finder software. Fracture on the models was simulated by applying a mechanical load to the palm in a direction parallel to the forearm axis, after which the fracture load and the site at which the fracture began were identified. For comparison, the wrists were fractured using a universal testing machine and the fracture load and the site of fracture were identified. The fracture load was 970.9 N in the finite element model group and 990.0 N in the actual measurement group. The site of the initial fracture was extra-articular to the distal radius in both groups. The finite element model was predictive for distal radius fracture when compared to the actual measurement. In this study, a finite element model for evaluation of distal radius strength was validated and can be used to predict fracture risk. We conclude that a finite element model is useful for the evaluation of distal radius strength. Knowing distal radius strength might avoid distal radius fracture because appropriate antiosteoporotic treatment can be initiated.

  7. Midterm Follow-up of Treating Volar Marginal Rim Fractures with Variable Angle Lcp Volar Rim Distal Radius Plates.

    Science.gov (United States)

    Goorens, Chul Ki; Geeurickx, Stijn; Wernaers, Pascal; Staelens, Barbara; Scheerlinck, Thierry; Goubau, Jean

    2017-06-01

    Specific treatment of the volar marginal rim fragment of distal radius fractures avoids occurance of volar radiocarpal dislocation. Although several fixation systems are available to capture this fragment, adequately maintaining internal fixation is difficult. We present our experience of the first 10 cases using the 2.4 mm variable angle LCP volar rim distal radius plate (Depuy Synthes®, West Chester, US), a low-profile volar rim-contouring plate designed for distal plate positioning and stable buttressing of the volar marginal fragment. Follow-up patient satisfaction, range of motion, grips strength, functional scoring with the QuickDASH and residual pain with a numeric rating scale were assessed. Radiological evaluation consisted in evaluating fracture consolidation, ulnar variance, volar angulation and maintenance of the volar rim fixation. The female to male ratio was 5:5 and the mean age was 52.2 (range, 17-80) years. The mean follow-up period was 11 (range, 5-19) months postoperatively. Patient satisfaction was high. The mean total flexion/extension range was 144° (range, 100-180°) compared to the contralateral uninjured side 160° (range, 95-180°). The mean total pronation/supination range was 153° (range, 140-180°) compared to the contralateral uninjured side 170° (range, 155-180°). Mean grip strength was 14 kg (range, 9-22), compared to the contralateral uninjured side 20 kg (range, 12-25 kg). Mean pre-injury level activity QuickDASH was 23 (range, 0-34.1), while post-recovery QuickDASH was 25 (range 0-43.2). Residual pain was 1.5 on the visual numerical pain rating scale. Radiological evaluation revealed in all cases fracture consolidation, satisfactory reconstruction of ulnar variance, volar angulation and volar rim. We encountered no flexor tendon complications, although plate removal was systematically performed after fracture consolidation. The 2.4 mm variable angle LCP volar rim distal radius plates is a valid treatment option for treating

  8. Volar plating for distal radius fractures--do not trust the image intensifier when judging distal subchondral screw length.

    Science.gov (United States)

    Park, Derek H; Goldie, Boyd S

    2012-09-01

    The use of the volar plate to treat distal radius fractures is increasing but despite the theoretical advantages of a volar approach there have been reports of extensor tendon ruptures due to prominent screw tips protruding past the dorsal cortex. The valley in the intermediate column between Lister tubercle and the sigmoid notch of the distal radius makes it difficult to rely on fluoroscopy to judge screw length. Our aim was to quantify the dimensions of this valley and to demonstrate the danger of relying on intraoperative image intensification fluoroscopy to determine lengths of distal screws. We measured the depth of this valley in the intermediate column of the distal radius in 33 patients with computed tomographic (9 patients) or magnetic resonance image (24 patients) scans of the wrist. There was a consistent valley in all images examined [average 1.8 mm (95% confidence interval, 1.6-2.0 mm)]. Thirty-nine percent of wrists had a valley depth of at least 2 mm. Standard lateral views or rotation of the forearm to obtain oblique views does not identify prominent screw tips; and whatever the rotation of the forearm, screw tips protruding beyond dorsal cortex may look as if it is within the bone when in fact it is out. When drilling we suggest noting the depth at which the drill bit just penetrates dorsal cortex and routinely downsize the distal screw length by 2 mm. We caution against relying on flourosocopy when judging the length of the distal subchondral screws.

  9. Examination of Skill Acquisition and Grader Bias in a Distal Radius Fracture Fixation Model.

    Science.gov (United States)

    Putnam, Matthew D; Adams, Julie E; Lender, Paul; Van Heest, Ann E; Shanedling, Janet R; Nuckley, David J; Bechtold, Joan E

    2018-03-01

    Primary: Assess the ability of faculty graders to predict the objectively measured strength of distal radius fracture fixation. Secondary: Compare resident skill variation and retention related to other knowable training data. Residents were allowed 60 minutes to stabilize a standardized distal radius fracture using an assigned fixed-angle volar plate. Faculty observed and subjectively graded the residents without providing real-time feedback. Objective biomechanical evaluation (construct strength and stiffness) was compared to subjective grades. Resident-specific characteristics (sex, PGY, and ACGME case log) were also used to compare the objective data. A simulated operating room in our laboratory. Post-graduate year 2, 3, 4, and 5 orthopedic residents. Primary: Faculty were not successful at predicting objectively measured fixation, and their subjective scoring suggests confirmation bias as PGY increased. Secondary: Resident year-in-training alone did not predict objective measures (p = 0.53), but was predictive of subjective scores (p external faculty unfamiliar with tested residents, might alter these results. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  10. The effects of implant composition on extensor tenosynovitis in a canine distal radius fracture model.

    Science.gov (United States)

    Sinicropi, Stefano M; Su, Brian W; Raia, Frank J; Parisien, May; Strauch, Robert J; Rosenwasser, Melvin P

    2005-03-01

    Dorsal plating of distal radius fractures with titanium plates has resulted in clinically observed tenosynovitis and tendon rupture. The goal of this study was to investigate whether titanium-based implants result in more extensor tendon inflammation than matched stainless-steel implants in a canine fracture model. An osteotomy was created in the distal radius of 18 beagles and fixed with 2.7-mm 4-hole plates composed of commercially pure titanium, titanium alloy (Ti-Al6-V4), or 316L stainless steel. Animals were killed at an average of 4 months. Tendon gliding was assessed by applying a force at the extensor musculotendinous junction and noting gliding. Histologic grading (mild, moderate, severe) was based on cellular hypertrophy, hyperplasia, and leukocytic infiltration. Tendons glided freely in 100% stainless-steel specimens, 75% of titanium alloy, and 43% of commercially pure titanium groups. A severe inflammatory reaction was identified in 60% of the titanium alloy (Ti-A16-V4) group, 57% of the pure titanium group, and 0% of the stainless-steel group. Dorsal plating of the canine radius with commercially pure titanium or titanium alloy implants produced a greater inflammatory peritendinous response than matched stainless-steel implants.

  11. Nerve Stimulator Guided Axillary Block in Painless Reduction of Distal Radius Fractures; a Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Hossein Alimohammadi

    2013-12-01

    Full Text Available Introduction: Given the high prevalence of upper extremity fractures and increasing need to perform painless reduction in the emergency departments, the use of analgesic methods with fewer complications and more satisfaction appears to be essential. The aim of this study is comparison the nerve stimulator guided axillary block (NSAB with intravenous sedation in induction of analgesia for painless reduction of distal radius fractures. Methods: In the present randomized clinical trial, 60 patients (18-70 years of age suffered from distal radius fractures, were divided into two equal groups. One group received axillary nerve block by nerve stimulator guidance and the other procedural sedation and analgesia (PSA using midazolam/fentanyl. Onset of analgesia, duration of analgesic effect, total procedure time and pain scores were recorded using visual analogue scale (VAS and the outcomes were compared. Chi-squared and student t test were performed to evaluate differences between two groups. Results: Sixty patients were randomly divided into two groups (83.3% male. The mean age of patients was 31 ±0.7 years. While the onset of analgesia was significantly longer in the NSAB group, the mean total time of procedure was shorter than PSA (p<0.001. The NSAB group needed a shorter post-operative observation time (P<0.001. Both groups experienced equal pain relief before, during and after procedure (p>0.05. Conclusion: It seems that shorter post-operative monitoring time and consequently lesser total time of procedure, make nerve stimulator guided axillary block as an appropriate alternative for procedural sedation and analgesia in painless reduction of distal radius fractures in emergency department. 

  12. Outcome of management of distal radius fractures in ...

    African Journals Online (AJOL)

    Background and Purpose: Distal radial fractures are common fractures of postmenopausal age group patients. They are often called fractures of osteoporosis. These fractures are considered to be one of the commonest minor injuries to cause major morbidity in the community. A lot of patient who need surgery, fail to afford ...

  13. Effect of facility on the operative costs of distal radius fractures.

    Science.gov (United States)

    Mather, Richard C; Wysocki, Robert W; Mack Aldridge, J; Pietrobon, Ricardo; Nunley, James A

    2011-07-01

    The purpose of this study was to investigate whether ambulatory surgery centers can deliver lower-cost care and to identify sources of those cost savings. We performed a cost identification analysis of outpatient volar plating for closed distal radius fractures at a single academic medical center. Multiple costs and time measures were taken from an internal database of 130 consecutive patients and were compared by venue of treatment, either an inpatient facility or an ambulatory, stand-alone surgery facility. The relationships between total cost and operative time and multiple variables, including fracture severity, patient age, gender, comorbidities, use of bone graft, concurrent carpal tunnel release, and surgeon experience, were examined, using multivariate analysis and regression modeling to identify other cost drivers or explanatory variables. The mean operative cost was considerably greater at the inpatient facility ($7,640) than at the outpatient facility ($5,220). Cost drivers of this difference were anesthesia services, post-anesthesia care unit, and operating room costs. Total surgical time, nursing time, set-up, and operative times were 33%, 109%, 105%, and 35% longer, respectively, at the inpatient facility. There was no significant difference between facilities for the additional variables, and none of those variables independently affected cost or operative time. The only predictor of cost and time was facility type. This study supports the use of ambulatory stand-alone surgical facilities to achieve efficient resource utilization in the operative treatment of distal radius fractures. We also identified several specific costs and time measurements that differed between facilities, which can serve as potential targets for tertiary facilities to improve utilization. Economic and Decisional Analysis III. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  14. AO Distal Radius Fracture Classification: Global Perspective on Observer Agreement

    Science.gov (United States)

    Jayakumar, Prakash; Teunis, Teun; Giménez, Beatriz Bravo; Verstreken, Frederik; Di Mascio, Livio; Jupiter, Jesse B.

    2016-01-01

    Background The primary objective of this study was to test interobserver reliability when classifying fractures by consensus by AO types and groups among a large international group of surgeons. Secondarily, we assessed the difference in inter- and intraobserver agreement of the AO classification in relation to geographical location, level of training, and subspecialty. Methods A randomized set of radiographic and computed tomographic images from a consecutive series of 96 distal radius fractures (DRFs), treated between October 2010 and April 2013, was classified using an electronic web-based portal by an invited group of participants on two occasions. Results Interobserver reliability was substantial when classifying AO type A fractures but fair and moderate for type B and C fractures, respectively. No difference was observed by location, except for an apparent difference between participants from India and Australia classifying type B fractures. No statistically significant associations were observed comparing interobserver agreement by level of training and no differences were shown comparing subspecialties. Intra-rater reproducibility was “substantial” for fracture types and “fair” for fracture groups with no difference accounting for location, training level, or specialty. Conclusion Improved definition of reliability and reproducibility of this classification may be achieved using large international groups of raters, empowering decision making on which system to utilize. Level of Evidence Level III PMID:28119795

  15. The outcome of conservative treatment of adult distal radius fractures compared with the other wrist: radiological and functional evaluation

    Directory of Open Access Journals (Sweden)

    Mustafa Uslu

    2014-09-01

    Full Text Available Objective: This study was designed to evaluate anatomical and functional results of closed reduction-long arm cast treatment for distal radius fractures and compared other healthy wrist in the adults. Methods: 77 patients with distal radius fracture were treated conservatively between January 2010 and December 2010. The fractures were classified according to AO and Frykman classification system and investigated prospectively. The radiological and anatomical results were assessed by the Stewart score criteria. The functional results were assessed by Quick-Disability of Arm, Shoulder and Hand questionnaire (Q-DASH and the Stewart II score criteria. The mean follow-up of patients was 12 months. Results: The forty patients had right wrist fractured, 37 patients had left wrist fractured. According to Frykman classification 46 patients were type I-II fractured, according to AO classification 59 patients were type 23,A2,1 and 23,A2,2 fractured. According to Stewart the radiological and anatomical, the result were excellent in 57, good in 17, fair in 3. According to Stewart II functional criteria, the results were assessed excellent in 57, good in 8, fair in 12 The mean Q-DASH score was 6,37. The overall complication rate was 12.98%. Mild Carpal tunnel syndrome was observed in the two patients, ulna styloid nonunion in the four patients, pain of distal radioulnar joint in the one patient, mild carpal tunnel syndrome and tenderness of distal radioulnar joint in the three patients. Conclusion: Closed reduction and cast immobilization is still an effective and inexpensive treatment method in distal radial fractures. J Clin Exp Invest 2014; 5 (3: 403-409

  16. Fixation via dorsal for complex fractures of radius distal with plate P

    International Nuclear Information System (INIS)

    Rojas, Sandra; Bocanegra, Sergio; Suarez, Fabio

    2002-01-01

    The existence of multiple alternatives in the handling of the complex fractures of the radius distal it constitutes a reflection of the challenge that these they represent as for the possibility of recovering an appropriate consistency to articulate and orientation and radial height. This prospective study included 13 patients assisted in the hospital military of Bogota, by means of internal fixation with plate π. This treatment alternative, it solves many present inconveniences with other methods and it allows the precocious postoperative rehabilitation

  17. Complaints in the follow-up of conservatively treated distal radius fractures - predictors in the initial radiograph

    International Nuclear Information System (INIS)

    Freund, W.; Aschoff, A.J.; Einsiedel, T.; Kramer, M.; Trnavac, S.; Bezirkskrankenhaus Guenzburg

    2007-01-01

    Purpose: Radius fractures are frequent in adults, and the long-term results of conservative treatment remain disappointing. This study examines predictors for the clinical outcome in the initial radiograph. This will help to identify patients who will benefit from surgical treatment. Materials and Methods: A cohort study including a standardized telephone interview (Cooney score) was used to identify all conservatively treated patients with a distal radius fracture over a five-year period. The additional selection criteria were: over 15 years old, initial X-ray available, patient reachable by phone for the follow-up interview. The following measurements were taken from the initial radiograph: Radius-base angle, radial shortening, radiopalmar angle and intraarticular displacement. Correlations and a simple test to predict negative outcome were computed. Results: Of the initially identified 2211 patients with distal radius fracture, 179 also fulfilled the other criteria. The patients were 56.2 years old on average (standard deviation SD = ± 22.45 years) and 72 % were female. 60 % of the fractures were on the right side. The average follow-up was 4.3 years (SD ± 1.66). The Cooney score results averaged 85 points (with 100 being the optimal and maximum score), indicating good or very good functional results in the long term follow-up for 61 % of patients. However, 31 % received a rating of fair or poor and therefore had an unfavorable outcome. With respect to the correlations, age and shortening of the radius (but not gender) had a significant influence on the functional result. Using an age of 75 years or above and a radial shortening of at least 4 mm to predict an unfavorable outcome, the sensitivity is only 16 %, but the positive predictive value is 73 % and the specificity is 96 %. (orig.)

  18. The International Classification of Functioning as an explanatory model of health after distal radius fracture: A cohort study

    Directory of Open Access Journals (Sweden)

    MacDermid Joy C

    2005-11-01

    Full Text Available Abstract Background Distal radius fractures are common injuries that have an increasing impact on health across the lifespan. The purpose of this study was to identify health impacts in body structure/function, activity, and participation at baseline and follow-up, to determine whether they support the ICF model of health. Methods This is a prospective cohort study of 790 individuals who were assessed at 1 week, 3 months, and 1 year post injury. The Patient Rated Wrist Evaluation (PRWE, The Wrist Outcome Measure (WOM, and the Medical Outcome Survey Short-Form (SF-36 were used to measure impairment, activity, participation, and health. Multiple regression was used to develop explanatory models of health outcome. Results Regression analysis showed that the PRWE explained between 13% (one week and 33% (three months of the SF-36 Physical Component Summary Scores with pain, activities and participation subscales showing dominant effects at different stages of recovery. PRWE scores were less related to Mental Component Summary Scores, 10% (three months and 8% (one year. Wrist impairment scores were less powerful predictors of health status than the PRWE. Conclusion The ICF is an informative model for examining distal radius fracture. Difficulty in the domains of activity and participation were able to explain a significant portion of physical health. Post-fracture rehabilitation and outcome assessments should extend beyond physical impairment to insure comprehensive treatment to individuals with distal radius fracture.

  19. The International Classification of Functioning as an explanatory model of health after distal radius fracture: A cohort study

    Science.gov (United States)

    Harris, Jocelyn E; MacDermid, Joy C; Roth, James

    2005-01-01

    Background Distal radius fractures are common injuries that have an increasing impact on health across the lifespan. The purpose of this study was to identify health impacts in body structure/function, activity, and participation at baseline and follow-up, to determine whether they support the ICF model of health. Methods This is a prospective cohort study of 790 individuals who were assessed at 1 week, 3 months, and 1 year post injury. The Patient Rated Wrist Evaluation (PRWE), The Wrist Outcome Measure (WOM), and the Medical Outcome Survey Short-Form (SF-36) were used to measure impairment, activity, participation, and health. Multiple regression was used to develop explanatory models of health outcome. Results Regression analysis showed that the PRWE explained between 13% (one week) and 33% (three months) of the SF-36 Physical Component Summary Scores with pain, activities and participation subscales showing dominant effects at different stages of recovery. PRWE scores were less related to Mental Component Summary Scores, 10% (three months) and 8% (one year). Wrist impairment scores were less powerful predictors of health status than the PRWE. Conclusion The ICF is an informative model for examining distal radius fracture. Difficulty in the domains of activity and participation were able to explain a significant portion of physical health. Post-fracture rehabilitation and outcome assessments should extend beyond physical impairment to insure comprehensive treatment to individuals with distal radius fracture. PMID:16288664

  20. The prevalence of pain and disability one year post fracture of the distal radius in a UK population: A cross sectional survey

    Directory of Open Access Journals (Sweden)

    Leonardi-Bee Jo

    2008-09-01

    Full Text Available Abstract Background A fracture of the distal radius is a commonly occurring fracture and accounts for a third of all fractures in the elderly. Thus far, one year estimates of pain and disability following a fracture of the distal radius have been reported on Canadian populations. The primary aim of this study is to investigate the prevalence of pain and disability in a UK population one year post fracture of the distal radius. Methods A cross-sectional survey was undertaken, of all subjects suffering a fracture of the distal radius between October 2005 and February 2006 in Nottingham, UK. Primary outcomes used were the VAS for pain and the DASH for disability. Prevalence of pain and disability were calculated and odds ratios presented for associations between demographics, pain and disability. Results 93/264 (35% subjects responded to the questionnaire. 6 subjects did not fulfill the inclusion criteria and were excluded from further analysis. 11% of subjects reported moderate to very severe pain. 16% of subjects reported moderate to very severe disability. Statistically significant associations were found between pain medication usage for the wrist fracture and moderate to very severe pain (OR 11.20, 95% CI 2.05 – 61.23. Moderate to very severe disability was associated with older age (OR 6.53, 95%CI 1.65 – 25.90 and pain medication usage for the wrist fracture (OR 4.75, 95% CI 1.38 – 16.37. Working was associated with a reduction in risk of moderate to very severe disability (OR 0.14, 95% CI 0.03 – 0.67. Conclusion This study demonstrates that there are a small proportion of patients who are still suffering moderate to very severe pain and disability one year post fracture of the distal radius. The study also demonstrates that there are significant associations between characteristics of the patients and the level of pain and disability. This highlights the need for further research into the most appropriate management of these patients

  1. [Roof folding and rotary pushing for the treatment of back to back fractures of distal radius and ulna in children].

    Science.gov (United States)

    Xu, Ping; Dong, Xiao-jun; Lu, Zhou-tong; Wang, Gongjun; Zhang, Han-qing; Chen, Xuan-ning; Li, Dong

    2015-09-01

    To evaluate the technique and the clinical effect of folding roof and rotary pushing in treatment of children with distal radius and ulna fracture of "back to back". From January 2012 to February 2014,38 children with distal radius and ulna fracture of "back to back" were treated by using the technique of folding roof and rotary pushing to reset and splint fixation including 23 males and 15 females with an average age of 9.5 years old ranging from 6 to 14 years old. Injury time was from 45 min to 3 days (averaged 1.3 days). All cases was unilateral closed fracture without symptoms of nerve injury occurred. The wrist joint anteroposterior and lateral radiographs showed double fracture of radius and ulna, and the broken end of radius was typical "back to back" displacement. The quality of reduction was assessed according to Dienst recommendation on the combination of Aro measurement, and the therapeutic effect was evaluated using standard of Anderson function. All patients were followed up from 3 to 13 months with an average of 6 months. There were no iatrogenic nerve injury. Thirty cases were treated successfully for the first time, 8 cases were again reset successfully; 28 cases were anatomical reduction, 7 cases were near anatomic reduction, 3 cases were functional reduction. At the second day 7 cases with hand and finger swelling appeared in multiple reset patients. Quality results of reduction were excellent in 33 cases, good in 5 cases. According to the standard of Anderson function evaluation, 35 cases were excellent, 3 cases were good. All fractures were healed with of deformity of wrist. Using the technique of folding roof and rotary pushing in treatment of children with distal radius and ulna fracture of "back to back" is very successful, the patient's limb function recovered well, the whole operation process is simple.

  2. Ipsilateral simultaneous fracture of the trochlea involving the lateral end clavicle and distal end radius: a rare combination and a unique mechanism of injury

    Directory of Open Access Journals (Sweden)

    Gupta RK

    2014-07-01

    Full Text Available 【Abstract】Isolated trochlea fracture in adults is a rare surgical entity as compared to its capitellar counterpart. It has been only mentioned sporadically in the literature as case reports. Fracture of the trochlea is accompanied by other elbow injuries like elbow dislocation, capitellum fracture, ulnar fracture and extraarticular condylar fracture. Here we report a unique case of isolated displaced trochlea fracture associated with fractures of the lateral end clavicle and the distal end radius. We propose a unique mechanism for this rare combination of injuries: typical triad of injury, i.e. fracture of the distal end radius with trochlea and fracture of the lateral end of the clavicle. Nonoperative treatment is recommended for undisplaced humeral trochlea fractures; but for displaced ones, anatomical reduction and internal fixation are essential to maintain the congruous trochleacoronoid articulation and hence to maintain the intrinsic stability of the elbow. Key words: Isolated trochlea fracture; Clavicle; Radius fractures

  3. Factors in secondary prevention subsequent to distal radius fracture : Focus on physical function, co-morbidity, bone mineral density and health-related quality of life

    OpenAIRE

    Nordvall, Helena

    2009-01-01

    In Sweden approximately 25000 distal radius fractures occur annually, which is 37 % of all fractures related to osteoporosis. In this thesis, risk factors for osteoporosis, bone mineral density (BMD) and health-related quality of life (the SF-36) were compared in patients who suffered a distal radius fracture after low energy trauma with a control group matched on the basis of age, gender, and municipality of residence. The aim was also to analyse, among these patients, whether a risk factor ...

  4. Trajectories in quality of life of patients with a fracture of the distal radius or ankle using latent class analysis

    NARCIS (Netherlands)

    van Son, M.A.C.; de Vries, J.; Zijlstra, W.; Roukema, J.A.; Gosens, T.; Verhofstad, M. H. J.; den Oudsten, B.L.

    2017-01-01

    Purpose This prospective study aimed to identify the different trajectories of quality of life (QOL) in patients with distal radius fractures (DRF) and ankle fractures (AF). Secondly, it was examined if subgroups could be characterized by sociodemographic, clinical, and psychological variables.

  5. Association of Insulin-like Growth Factor-1, Bone Mass and Inflammation to Low-energy Distal Radius Fractures and Fracture Healing in Elderly Women Attending Emergency Care.

    Science.gov (United States)

    Chisalita, Simona I; Chong, Lee Ti; Wajda, Maciej; Adolfsson, Lars; Woisetschläger, Mischa; Spångeus, Anna

    2017-11-01

    Elderly patients suffer fractures through low-energy mechanisms. The distal radius is the most frequent fracture localization. Insulin-like growth factor-1 (IGF1) plays an important role in the maintenance of bone mass and its levels decline with advancing age and in states of malnutrition. Our aim was to investigate the association of IGF1 levels, bone mass, nutritional status, and inflammation to low-energy distal radius fractures and also study if fracture healing is influenced by IGF1, nutritional status, and inflammation. Postmenopausal women, 55 years or older, with low-energy distal radius fractures occurring due to falling on slippery ground, indoors or outdoors, were recruited in the emergency department (ED) and followed 1 and 5 weeks after the initial trauma with biomarkers for nutritional status and inflammation. Fractures were diagnosed according to standard procedure by physical examination and X-ray. All patients were conservatively treated with plaster casts in the ED. Patients who needed interventions were excluded from our study. Fracture healing was evaluated from radiographs. Fracture healing assessment was made with a five-point scale where the radiological assessment included callus formation, fracture line, and stage of union. Blood samples were taken within 24 h after fracture and analyzed in the routine laboratory. Bone mineral density (BMD) was measured by dual-energy X-ray absorptiometry (DXA). Thirty-eight Caucasian women, aged 70.5 ± 8.9 years (mean ± SD) old, were recruited. Nutritional status, as evaluated by albumin (40.3 ± 3.1 g/L), IGF1 (125.3 ± 39.9 μg/L), body mass index (26.9 ± 3.6 kg/m 2 ), arm diameter (28.9 ± 8.9 cm), and arm skinfold (2.5 ± 0.7 cm), was normal. A positive correlation was found between IGF1 at visit 1 and the lowest BMD for hip, spine, or radius (r = 0.39, P = 0.04). High sensitive C-reactive protein (hsCRP) and leukocytes were higher at the fracture event compared to 5 weeks later (P = 0.07 and P

  6. Bone strength and muscle properties in postmenopausal women with and without a recent distal radius fracture.

    Science.gov (United States)

    Crockett, K; Arnold, C M; Farthing, J P; Chilibeck, P D; Johnston, J D; Bath, B; Baxter-Jones, A D G; Kontulainen, S A

    2015-10-01

    Distal radius (wrist) fracture (DRF) in women over age 50 years is an early sign of bone fragility. Women with a recent DRF compared to women without DRF demonstrated lower bone strength, muscle density, and strength, but no difference in dual-energy x-ray absorptiometry (DXA) measures, suggesting DXA alone may not be a sufficient predictor for DRF risk. The objective of this study was to investigate differences in bone and muscle properties between women with and without a recent DRF. One hundred sixty-six postmenopausal women (50-78 years) were recruited. Participants were excluded if they had taken bone-altering medications in the past 6 months or had medical conditions that severely affected daily living or the upper extremity. Seventy-seven age-matched women with a fracture in the past 6-24 months (Fx, n = 32) and without fracture (NFx, n = 45) were measured for bone and muscle properties using the nondominant (NFx) or non-fractured limb (Fx). Peripheral quantitative computed tomography (pQCT) was used to estimate bone strength in compression (BSIc) at the distal radius and tibia, bone strength in torsion (SSIp) at the shaft sites, muscle density, and area at the forearm and lower leg. Areal bone mineral density at the ultradistal forearm, spine, and femoral neck was measured by DXA. Grip strength and the 30-s chair stand test were used as estimates of upper and lower extremity muscle strength. Limb-specific between-group differences were compared using multivariate analysis of variance (MANOVA). There was a significant group difference (p lower leg, with the Fx group demonstrating 16 and 19% lower BSIc, 3 and 6% lower muscle density, and 20 and 21% lower muscle strength at the upper and lower extremities, respectively. There were no differences between groups for DXA measures. Women with recent DRF had lower pQCT-derived estimated bone strength at the distal radius and tibia and lower muscle density and strength at both extremities.

  7. Radius crossover sign: an indication of malreduced radius shaft greenstick fractures.

    Science.gov (United States)

    Wright, Patrick B; Crepeau, Allison E; Herrera-Soto, José A; Price, Charles T

    2012-06-01

    Radius shaft greenstick fractures in children can be a challenging injury to treat because angulation and rotational alignment are difficult to assess. In this report, we describe a simple method for analyzing the deformity and identifying rotational and angular malalignment. This technique involves analyzing the forearm radiographs as 2 segments, proximal and distal, and assuring that the rotational position of each matches the other. We present 3 cases of proximal radius greenstick fractures in malalignment to demonstrate the radius crossover sign. Identifying the radius crossover sign, and proceeding with further closed reduction may prevent deformity that could otherwise result in a significant loss of forearm motion. Level V.

  8. Mechanism of distal radius fracture as analyzed by 3D finite element model

    International Nuclear Information System (INIS)

    Tomizawa, Kazuo

    2007-01-01

    The purpose of this study is to see the difference of distal radius fracture between normal and osteoporotic bones and in its patterns due to limb position at injury through simulation and analysis of the biomechanics using three-dimensional (3D) finite element model. CT images were taken with SIEMENS machine, of right wrist joints of 32 and 76 years old, normal healthy man and osteoporotic woman, respectively. The wrist joint angles at CT were 70 degrees both at dorsiflexion and at palmerflexion for simulating fracture at tumbling down. The 3D bone model reconstructed from CT images with Forge software (Studio PON) was trimmed to remain the distal radial-ulnar portion and proximal carpal bones to make simulation easer, and the simplified 3D model was divided to 56,622 elements and 13,274 nodal points (normal bone) or 51,760 and 12,940 (osteoporosis), respectively, in 3 areas of different bone densities calculated with Scion Image processor. This 3D finite element model was analyzed with the software ANSYS LS-DYNA 10.0 for simulating the fracture (the defined yield stress attained) by impacting the elements of carpal bones to the radial bone joint surface with a measure of Mises stress. In osteoporotic bone, fracture was found to occur at dorsal cortex closer to the joint surface. Fracture occurred at dorsal and palmer cortex at dorsiflexion and palmerflexion, respectively. (R.T.)

  9. Epidemiology of distal radius fractures in polytrauma patients and the influence of high traumatic energy transfer.

    Science.gov (United States)

    Ferree, Steven; van der Vliet, Quirine M J; Nawijn, Femke; Bhashyam, Abhiram R; Houwert, Roderick M; Leenen, Luke P H; Hietbrink, Falco

    2018-03-01

    For several extremity fractures differences in morphology, incidence rate and functional outcome were found when polytrauma patients were compared to patients with an isolated injury. This is not proven for distal radius fractures (DRF). Therefore, this study aimed to analyse fracture morphology in relation to energy transfer in both poly- and mono-trauma patients with a DRF. This was a retrospective cohort study. All patients aged 16 years and older with a DRF were included. Patients with an Injury Severity Score of 16 or higher were classified as polytrauma patients. Injuries were defined as high or low energy. All DRFs were classified using the AO/OTA fracture classification system. A total of 830 patients with a DRF were included, 12% were polytrauma. The incidence rate of DRF in polytrauma patients was 3.5%. Ipsilateral upper extremity injury was found in >30% of polytrauma and high-energy monotrauma patients, compared to 5% in low-energy monotrauma patients. More type C DRF were found in polytrauma and high-energy monotrauma patients versus low-energy monotrauma patients. Operative intervention rates for all types of DRF were similar for polytrauma and high-energy monotrauma patients. Non-union rates were higher in polytrauma patients. Higher energy mechanisms of injury, in polytrauma and high-energy monotrauma patients, were associated with more severe complex articular distal radius fractures and more ipsilateral upper extremity injuries. Polytrauma and high-energy monotrauma patient have a similar fracture morphology. However, polytrauma patients have in addition to more injured body regions also more non-union related interventions than high-energy monotrauma patients. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Cross-education for improving strength and mobility after distal radius fractures: a randomized controlled trial.

    Science.gov (United States)

    Magnus, Charlene R A; Arnold, Cathy M; Johnston, Geoffrey; Dal-Bello Haas, Vanina; Basran, Jenny; Krentz, Joel R; Farthing, Jonathan P

    2013-07-01

    To evaluate the effects of cross-education (contralateral effect of unilateral strength training) during recovery from unilateral distal radius fractures on muscle strength, range of motion (ROM), and function. Randomized controlled trial (26-wk follow-up). Hospital, orthopedic fracture clinic. Women older than 50 years with a unilateral distal radius fracture. Fifty-one participants were randomized and 39 participants were included in the final data analysis. Participants were randomized to standard rehabilitation (Control) or standard rehabilitation plus strength training (Train). Standard rehabilitation included forearm casting for 40.4±6.2 days and hand exercises for the fractured extremity. Nonfractured hand strength training for the training group began immediately postfracture and was conducted at home 3 times/week for 26 weeks. The primary outcome measure was peak force (handgrip dynamometer). Secondary outcomes were ROM (flexion/extension; supination/pronation) via goniometer and the Patient Rated Wrist Evaluation questionnaire score for the fractured arm. For the fractured hand, the training group (17.3±7.4kg) was significantly stronger than the control group (11.8±5.8kg) at 12 weeks postfracture (P<.017). There were no significant strength differences between the training and control groups at 9 (12.5±8.2kg; 11.3±6.9kg) or 26 weeks (23.0±7.6kg; 19.6±5.5kg) postfracture, respectively. Fractured hand ROM showed that the training group had significantly improved wrist flexion/extension (100.5°±19.2°) than the control group (80.2°±18.7°) at 12 weeks postfracture (P<.017). There were no significant differences between the training and control groups for flexion/extension ROM at 9 (78.0°±20.7°; 81.7°±25.7°) or 26 weeks (104.4°±15.5°; 106.0°±26.5°) or supination/pronation ROM at 9 (153.9°±23.9°; 151.8°±33.0°), 12 (170.9°±9.3°; 156.7°±20.8°) or 26 weeks (169.4°±11.9°; 162.8°±18.1°), respectively. There were no

  11. Elbow dislocation with ipsilateral fracture of the distal radius associated with a brachial artery injury: A new pathological condition of traumatic origin.

    Science.gov (United States)

    Trigo Lahoz, L; Lamas Gomez, C; Sarasquete Reiriz, J; de Caso Rodriguez, J; Proubasta Renart, I

    Elbow dislocation associated with ipsilateral fracture of the distal radius and a brachial artery injury is an uncommon traumatic entity. The two references of this injury combination appeared in 2015, although both authors did not realise that they were the first two cases published in the medical literature. Although mentioned in the text of the articles, no mention was made of the fracture of the distal radius in the titles. The purpose of this paper is to present three cases with this new traumatic pathological entity, explaining its pathogenetic mechanism, the treatment used, and the results obtained. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. [Clinical observation on the effect of joint mobilization in treating elderly patients after distal radius fractures operation].

    Science.gov (United States)

    Jia, Xue-Feng; Cai, Hong-Xin; Lin, Ge-Sheng; Fang, Ji-Shi; Wang, Yong; Wu, Zhi-Yong; Tu, Xu-Hui

    2017-07-25

    To investigate the effect of joint mobilization on postoperative wrist joint function, pain and grip strength for elderly patients with distal radius fracture. From January 2015 to June 2016, a total of 67 elderly patients with distal radius fracture were randomly divided into routine exercise group and joint mobilization group. Among them, 37 patients in the routine exercise group underwent conventional distal radius fracture postoperative joint function exercise regimen, including 16 males and 21 females with a mean age of (67.8±3.2) years old ranging from 60 to 72 years old;the injured side was dominant in 23 cases and non-dominant in 14 cases;injury mechanism was fall in 26 cases, traffic accident in 11 cases; for AO type, 6 cases were type B3, 18 cases were type C1, 7 cases were type C2, 6 cases was type C3. Other 30 patients in the joint mobilization group underwent joint mobilization on the basis of the routine exercise group including 14 males and 16 females with a mean age of (67.1±4.0) years old ranging from 61 to 74 years old; the injured side was dominant in 21 cases and non-dominant in 9 cases;injury mechanism was fall in 25 cases, traffic accident in 5 cases;for AO type, 8 cases were type B3, 13 cases were type C1, 6 cases were type C2, 9 cases were type C3. The wrist joint activity, Gartland-Werley wrist joint function score, VAS pain score and grip strength were observed at 3 months afrer treatment. After 3 months' treatment, the VAS in the routine exercise group was higher than that of the joint mobilization group ( P joint mobilization group was higher than that in routine exercise group( P joint mobilization group( P joint mobilization group had no significant difference ( P >0.05). In the comparison of each item of Gartland-Werley, there was no significant difference between two groups in residual deformity and complication( P >0.05); the average score of subjective score, objective score and total score in routine exercise group were

  13. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Suojaervi, Nora; Lindfors, N. [Helsinki University Central Hospital, Department of Hand Surgery, Helsinki (Finland); Sillat, T.; Koskinen, S.K. [HUS Helsinki Medical Imaging Center, Helsinki University Central Hospital, Department of Radiology, Helsinki (Finland)

    2015-12-15

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities. (orig.)

  14. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images.

    Science.gov (United States)

    Suojärvi, Nora; Sillat, T; Lindfors, N; Koskinen, S K

    2015-12-01

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities.

  15. Do radiographic indices of distal radius fracture reduction predict outcomes in older adults receiving conservative treatment?

    International Nuclear Information System (INIS)

    Jaremko, J.L.; Lambert, R.G.W.; Rowe, B.H.; Johnson, J.A.; Majumdar, S.R.

    2007-01-01

    Aim: To investigate whether radiographic deformities suggesting inadequate reduction would be associated with adverse clinical outcomes. Materials and methods: Consecutive patients over 50 years of age (n = 74) with non-operatively managed distal radius fractures were enrolled in a prospective cohort study. They had radiographs at cast removal (∼6 weeks) and completed DASH (Disabilities of the Arm, Shoulder and Hand), SF-12 (health-related quality of life), and satisfaction surveys 6-months post-fracture. A reference-standard musculoskeletal radiologist, blinded to outcomes status, measured palmar (dorsal) tilt, radial angle, radial height, ulnar height, and intra-articular step and gap. Radiographic indices were correlated to each other and to the various patient-reported outcomes in univariate and multivariate regression analyses. DASH score was the primary study outcome. Results: Of the cohort studied (n = 74, mean age 68.5 years, primarily white women), 71% had at least one 'unacceptable' radiographic deformity by traditional criteria. Acceptable reduction varied from 60-99% depending on which single index was reported, and 44% of patients had more than two indices reported as unacceptable. Despite these radiographic findings, 6-months post-reduction, self-reported disability was low (DASH = 24 ± 17), health-related quality of life was near normal, and 72% were satisfied with their care. No radiographic index of wrist deformity (alone or in combination) was significantly correlated to any of the patient-reported outcomes. Conclusion: Self-reported outcomes in older adults with conservatively managed wrist fractures were not related to the 'acceptability' of radiographic fracture reduction. The proportion of acceptable reductions varied by 40% depending on which index was reported. Consequently, detailed reporting of these indices in older adults with distal radius fracture may be inefficient or perhaps even unnecessary

  16. Do radiographic indices of distal radius fracture reduction predict outcomes in older adults receiving conservative treatment?

    Energy Technology Data Exchange (ETDEWEB)

    Jaremko, J.L. [Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta (Canada); Lambert, R.G.W. [Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta (Canada); Rowe, B.H. [Department of Emergency Medicine, University of Alberta, Edmonton, Alberta (Canada); Department of Public Health Sciences, University of Alberta, Edmonton, Alberta (Canada); Johnson, J.A. [Department of Public Health Sciences, University of Alberta, Edmonton, Alberta (Canada); Department of Medicine, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta (Canada); Majumdar, S.R. [Department of Public Health Sciences, University of Alberta, Edmonton, Alberta (Canada) and Department of Medicine, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta (Canada)]. E-mail: me2.majumdar@ualberta.ca

    2007-01-15

    Aim: To investigate whether radiographic deformities suggesting inadequate reduction would be associated with adverse clinical outcomes. Materials and methods: Consecutive patients over 50 years of age (n = 74) with non-operatively managed distal radius fractures were enrolled in a prospective cohort study. They had radiographs at cast removal ({approx}6 weeks) and completed DASH (Disabilities of the Arm, Shoulder and Hand), SF-12 (health-related quality of life), and satisfaction surveys 6-months post-fracture. A reference-standard musculoskeletal radiologist, blinded to outcomes status, measured palmar (dorsal) tilt, radial angle, radial height, ulnar height, and intra-articular step and gap. Radiographic indices were correlated to each other and to the various patient-reported outcomes in univariate and multivariate regression analyses. DASH score was the primary study outcome. Results: Of the cohort studied (n = 74, mean age 68.5 years, primarily white women), 71% had at least one 'unacceptable' radiographic deformity by traditional criteria. Acceptable reduction varied from 60-99% depending on which single index was reported, and 44% of patients had more than two indices reported as unacceptable. Despite these radiographic findings, 6-months post-reduction, self-reported disability was low (DASH = 24 {+-} 17), health-related quality of life was near normal, and 72% were satisfied with their care. No radiographic index of wrist deformity (alone or in combination) was significantly correlated to any of the patient-reported outcomes. Conclusion: Self-reported outcomes in older adults with conservatively managed wrist fractures were not related to the 'acceptability' of radiographic fracture reduction. The proportion of acceptable reductions varied by 40% depending on which index was reported. Consequently, detailed reporting of these indices in older adults with distal radius fracture may be inefficient or perhaps even unnecessary.

  17. Locking plate versus external fixation for type C distal radius fractures: A meta-analysis of randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Dong Wang

    2018-04-01

    Full Text Available Purpose: Distal radial fracture is one of the most common fractures. Up to now, locking plates (LP and external fixation (EF are two conventional surgical approaches to type C radius fracture. Which method is superior has not yet reached a consensus. We try to assess the clinical effectiveness of the two interventions by this meta-analysis. Methods: We used network to search the PubMed, Embase, and Cochrane Medical Library of randomized controlled clinical trials about the type C distal radius fractures performed according to the search strategy mentioned in Cochrane Handbook 5.1.0 from Jan. 2005 to Jan. 2016. Patients in the experimental group were used LP, in the control group were included EF and other surgical approaches. Publication language was restricted to English. Studies that patient population and surgical indication did not define had been excluded. Studies must report at least one of the outcomes as follow: radial inclination, palmar tilt, ulnar variance, range of wrist flexion and extension, and range of wrist supination and pronation. The trials in which participants included children were excluded. We used Jadad study scores to appraise the study. Results: Seven studies included 162 patients (LP group and 190 patients (EF group. We compared the radial inclination, palmar tilt, ulnar variance, range of wrist flexion and extension, and range of wrist supination and pronation. The radial inclination were revealed a difference favoring LP over EF [WMD = 1.84, 95% CI (0.17, 3.50, p = 0.03] and the palmar tilt and ulnar variance was no significant difference between the two groups [(WMD = 3.61, 95% CI (0.00, 7.23, p = 0.05; WMD = 0.05, 95% CI (−0.99, 1.09, p = 0.93]. The functional activities of range of flexion and extension and range of supination and pronation between the two groups was no difference [WMD = 10.04, 95% CI (−6.88, 26.96, p = 0.24; WMD = 12.53, 95% CI (−9.99, 35.06, p = 0.28]. Conclusion

  18. Non-operative treatment of displaced distal radius fractures leads to acceptable functional outcomes, however at the expense of 40% subsequent surgeries

    NARCIS (Netherlands)

    Mulders, M. A. M.; van Eerten, P. V.; Goslings, J. C.; Schep, N. W. L.

    2017-01-01

    Background: Although secondary displacement following closed reduction and plaster immobilisation is high, several guidelines still recommend non-operative treatment for displaced distal radius fractures with an adequate closed reduction. Purpose: The purpose of this study was to evaluate functional

  19. Fractal analysis of bone architecture at distal radius

    International Nuclear Information System (INIS)

    Tomomitsu, Tatsushi; Mimura, Hiroaki; Murase, Kenya; Sone, Teruki; Fukunaga, Masao

    2005-01-01

    Bone strength depends on bone quality (architecture, turnover, damage accumulation, and mineralization) as well as bone mass. In this study, human bone architecture was analyzed using fractal image analysis, and the clinical relevance of this method was evaluated. The subjects were 12 healthy female controls and 16 female patients suspected of having osteoporosis (age range, 22-70 years; mean age, 49.1 years). High-resolution CT images of the distal radius were acquired and analyzed using a peripheral quantitative computed tomography (pQCT) system. On the same day, bone mineral densities of the lumbar spine (L-BMD), proximal femur (F-BMD), and distal radius (R-BMD) were measured by dual-energy X-ray absorptiometry (DXA). We examined the correlation between the fractal dimension and six bone mass indices. Subjects diagnosed with osteopenia or osteoporosis were divided into two groups (with and without vertebral fracture), and we compared measured values between these two groups. The fractal dimension correlated most closely with L-BMD (r=0.744). The coefficient of correlation between the fractal dimension and L-BMD was very similar to the coefficient of correlation between L-BMD and F-BMD (r=0.783) and the coefficient of correlation between L-BMD and R-BMD (r=0.742). The fractal dimension was the only measured value that differed significantly between both the osteopenic and the osteoporotic subjects with and without vertebral fracture. The present results suggest that the fractal dimension of the distal radius can be reliably used as a bone strength index that reflects bone architecture as well as bone mass. (author)

  20. A retrospective, semi-quantitative image quality analysis of cone beam computed tomography (CBCT) and MSCT in the diagnosis of distal radius fractures

    International Nuclear Information System (INIS)

    Lang, H.; Neubauer, J.; Fritz, B.; Spira, E.M.; Strube, J.; Langer, M.; Kotter, E.

    2016-01-01

    To compare image quality and diagnostic validity of CBCT and MSCT for distal radius fractures. 35 CBCT and 33 MSCT scans were retrospectively reviewed with a visual grading scale regarding the depiction of cortical bone, trabecular bone, articular surfaces, and soft tissue. The extent and type of artefacts was analyzed. Agreement on AO classification and measurement of cortical disruption and length of the fracture gap was determined. Fracture reduction was evaluated in post-treatment x-rays. Statistical analysis was performed with visual grading characteristics (VGC), chi square tests, and Kendall's coefficient of concordance. CBCT performed significantly worse for cortical bone, articular surfaces, and especially soft tissue. Trabecular bone showed no significant difference. Significantly more CBCT images showed artefacts. Physics-based artefacts were the most common. CBCT scans also showed motion artefacts. There was no significant difference in agreement on AO classification. The agreement on measurements was substantial for both modalities. Slightly more fractures that had undergone MSCT imaging showed adequate reduction. This initial study of an orthopaedic extremity CBCT scanner showed that the image quality of a CBCT scanner remains inferior for most structures at standard settings. Diagnostic validity of both modalities for distal radius fractures seems similar. (orig.)

  1. Fragment-Specific Fixation Versus Volar Locking Plates in Primarily Nonreducible or Secondarily Redisplaced Distal Radius Fractures: A Randomized Controlled Study.

    Science.gov (United States)

    Landgren, Marcus; Abramo, Antonio; Geijer, Mats; Kopylov, Philippe; Tägil, Magnus

    2017-03-01

    To compare the patient-reported, clinical, and radiographic outcome of 2 methods of internal fixation in distal radius fractures. Fifty patients, mean age 56 years (range, 21-69 years) with primarily nonreducible or secondarily redisplaced distal radius fractures were randomized to open reduction internal fixation using volar locking plates (n = 25) or fragment-specific fixation (n = 25). The patients were assessed on grip strength, range of motion, patient-reported outcome (Quick Disabilities of the Arm, Shoulder, and Hand), pain (visual analog scale), health-related quality of life (Short Form-12 [SF-12]), and radiographic evaluation. Grip strength at 12 months was the primary outcome measure. At 12 months, no difference was found in grip strength, which was 90% of the uninjured side in the volar plate group and 87% in the fragment-specific fixation group. No differences were found in range of motion and the median Quick Disabilities of the Arm, Shoulder, and Hand score was 5 in both groups. The overall complication rate was significant, 21% in the volar locking plate group, compared with 52% in the fragment-specific group. In treatment of primarily nonreducible or secondarily redisplaced distal radius fractures, volar locking plates and fragment-specific fixation both achieve good and similar patient-reported outcomes, although more complications were recorded in the fragment-specific group. Therapeutic II. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  2. Open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs: 102 cases (2008-2015).

    Science.gov (United States)

    De Arburn Parent, Rebecca; Benamou, Jérôme; Gatineau, Matthieu; Clerfond, Pierre; Planté, Jérôme

    2017-06-15

    OBJECTIVE To determine outcomes and complication rates of open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs. DESIGN Retrospective case series. ANIMALS 102 miniature- and toy-breed dogs (105 fractures) weighing ≤ 7 kg (15.4 lb) that had undergone open reduction and cranial bone plate fixation of a fracture involving the distal aspect of the radius and ulna from 2008 through 2015. PROCEDURES Medical records were reviewed and information extracted regarding dog and fracture characteristics, surgical variables, and follow-up examination data (including postoperative complications). Postoperative radiographs were examined for distal fragment size, implant placement, apposition, alignment, and healing stage. A long-term follow-up questionnaire was completed by telephone interview with dog owners at least 6 months after surgery. RESULTS Mean length of the distal bone fragment in all fractures was 19.2 mm, with a mean distal-to-total radial length ratio of 0.21. At last follow-up examination (typically 6 weeks after surgery), 97 (95%) dogs had no signs of lameness; minor lameness was identified in 5 (5%) dogs. Complications developed in 26 (25%) fractures (23 [22%] minor and 3 [3%] major complications). Sixty-eight of 71 (96%) owners rated the overall and long-term outcome as excellent and 3 (4%) as good; 68 of 71 (96%) dogs reportedly had no signs of residual lameness. CONCLUSIONS AND CLINICAL RELEVANCE Open reduction and cranial bone plate fixation for the treatment of radius-ulna fractures in miniature- and toy-breed dogs provided an excellent outcome with a low complication rate.

  3. Linear intra-bone geometry dependencies of the radius: Radius length determination by maximum distal width

    International Nuclear Information System (INIS)

    Baumbach, S.F.; Krusche-Mandl, I.; Huf, W.; Mall, G.; Fialka, C.

    2012-01-01

    Purpose: The aim of the study was to investigate possible linear intra-bone geometry dependencies by determining the relation between the maximum radius length and maximum distal width in two independent populations and test for possible gender or age effects. A strong correlation can help develop more representative fracture models and osteosynthetic devices as well as aid gender and height estimation in anthropologic/forensic cases. Methods: First, maximum radius length and distal width of 100 consecutive patients, aged 20–70 years, were digitally measured on standard lower arm radiographs by two independent investigators. Second, the same measurements were performed ex vivo on a second cohort, 135 isolated, formalin fixed radii. Standard descriptive statistics as well as correlations were calculated and possible gender age influences tested for both populations separately. Results: The radiographic dataset resulted in a correlation of radius length and width of r = 0.753 (adj. R 2 = 0.563, p 2 = 0.592) and side no influence on the correlation. Radius length–width correlation for the isolated radii was r = 0.621 (adj. R 2 = 0.381, p 2 = 0.598). Conclusion: A relatively strong radius length–distal width correlation was found in two different populations, indicating that linear body proportions might not only apply to body height and axial length measurements of long bones but also to proportional dependency of bone shapes in general.

  4. Radiographic evaluation of acute distal radius fracture stability: A comparative cadaveric study between a thermo-formable bracing system and traditional fiberglass casting.

    Science.gov (United States)

    Santoni, Brandon G; Aira, Jazmine R; Diaz, Miguel A; Kyle Stoops, T; Simon, Peter

    2017-08-01

    Distal radius fractures are common musculoskeletal injuries and many can be treated non-operatively with cast immobilization. A thermo-formable brace has been developed for management of such fractures, but no data exist regarding its comparative stabilizing efficacy to fiberglass casting. A worst-case distal radius fracture was created in 6 cadaveric forearms. A radiolucent loading fixture was created to apply cantilever bending/compression loads ranging from 4.5N to 66.7N across the simulated fracture in the: (1) non-stabilized, (2) braced; and (3) casted forearms, each forearm serving as its own control. Fracture fragment translations and rotations were measured radiographically using orthogonal radiographs and a 2D-3D, CT-based transformation methodology. Under 4.5N of load in the non-stabilized condition, average sagittal plane rotation and 3D center of mass translation of the fracture fragment were 12.3° and 5.3mm, respectively. At the 4.5N load step, fragment rotation with the brace (avg. 0.0°) and cast (0.1°) reduced sagittal plane rotation compared to the non-stabilized forearm (Pthermo-formable brace stabilized the fracture in a manner that was not radiographically or biomechanically different from traditional fiberglass casting. Study results support the use of the thermo-formable brace clinically. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. A retrospective, semi-quantitative image quality analysis of cone beam computed tomography (CBCT) and MSCT in the diagnosis of distal radius fractures

    Energy Technology Data Exchange (ETDEWEB)

    Lang, H.; Neubauer, J.; Fritz, B.; Spira, E.M.; Strube, J.; Langer, M.; Kotter, E. [University Medical Center Freiburg, Department of Radiology, Freiburg (Germany)

    2016-12-15

    To compare image quality and diagnostic validity of CBCT and MSCT for distal radius fractures. 35 CBCT and 33 MSCT scans were retrospectively reviewed with a visual grading scale regarding the depiction of cortical bone, trabecular bone, articular surfaces, and soft tissue. The extent and type of artefacts was analyzed. Agreement on AO classification and measurement of cortical disruption and length of the fracture gap was determined. Fracture reduction was evaluated in post-treatment x-rays. Statistical analysis was performed with visual grading characteristics (VGC), chi square tests, and Kendall's coefficient of concordance. CBCT performed significantly worse for cortical bone, articular surfaces, and especially soft tissue. Trabecular bone showed no significant difference. Significantly more CBCT images showed artefacts. Physics-based artefacts were the most common. CBCT scans also showed motion artefacts. There was no significant difference in agreement on AO classification. The agreement on measurements was substantial for both modalities. Slightly more fractures that had undergone MSCT imaging showed adequate reduction. This initial study of an orthopaedic extremity CBCT scanner showed that the image quality of a CBCT scanner remains inferior for most structures at standard settings. Diagnostic validity of both modalities for distal radius fractures seems similar. (orig.)

  6. [Complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    Science.gov (United States)

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2016-12-20

    Objective: To make a systematic assessment of the complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Method: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed.The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected.The included trials were screened out strictly based on the criterion of inclusion and exclusion.The quality of included trials was evaluated.RevMan 5.0 was used for data analysis. Result: A total of 17 studies involving 1 402 patients were included.There were 687 patients with open reduction and internal fixation and 715 with external fixation.The results of Meta-analysis indicated that there were statistically significant differences with regard to the postoperatively total complications, infection, malunion, tendon rupture ( I 2 =8%, RR =0.77(95% CI 0.65-0.91, Z =3.10, P 0.05). Conclusion: Postoperative complications are present in both open reduction and internal fixation and external fixation.Compared with external fixation, open reduction and internal fixation is lower in total complications postoperatively, infection and malunion, but external fixation has lower tendon rupture incidence.

  7. Comparison of 2D radiography and a semi-automatic CT-based 3D method for measuring change in dorsal angulation over time in distal radius fractures

    Energy Technology Data Exchange (ETDEWEB)

    Christersson, Albert; Larsson, Sune [Uppsala University, Department of Orthopaedics, Uppsala (Sweden); Nysjoe, Johan; Malmberg, Filip; Sintorn, Ida-Maria; Nystroem, Ingela [Uppsala University, Centre for Image Analysis, Uppsala (Sweden); Berglund, Lars [Uppsala University, Uppsala Clinical Research Centre, UCR Statistics, Uppsala (Sweden)

    2016-06-15

    The aim of the present study was to compare the reliability and agreement between a computer tomography-based method (CT) and digitalised 2D radiographs (XR) when measuring change in dorsal angulation over time in distal radius fractures. Radiographs from 33 distal radius fractures treated with external fixation were retrospectively analysed. All fractures had been examined using both XR and CT at six times over 6 months postoperatively. The changes in dorsal angulation between the first reference images and the following examinations in every patient were calculated from 133 follow-up measurements by two assessors and repeated at two different time points. The measurements were analysed using Bland-Altman plots, comparing intra- and inter-observer agreement within and between XR and CT. The mean differences in intra- and inter-observer measurements for XR, CT, and between XR and CT were close to zero, implying equal validity. The average intra- and inter-observer limits of agreement for XR, CT, and between XR and CT were ± 4.4 , ± 1.9 and ± 6.8 respectively. For scientific purpose, the reliability of XR seems unacceptably low when measuring changes in dorsal angulation in distal radius fractures, whereas the reliability for the semi-automatic CT-based method was higher and is therefore preferable when a more precise method is requested. (orig.)

  8. Perbandingan Fungsi Extremitas Atas pada Fraktur Metafise Distal Radius Intraartikuler Usia Muda Antara Tindakan Operatif Dan Non Operatif dengan Penilaian Klinis Quickdash Score

    Directory of Open Access Journals (Sweden)

    Edi Burhan

    2014-01-01

    Full Text Available AbstrakFraktur metafise distal radius merupakan fraktur dengan insiden tertinggi kedua pada usia tua di luar fraktur daerah panggul. Di Rumah Sakit Dr. M. Djamil Padang terdapat 122 dari 612 kasus fraktur radius, antara Januari 2011 – Juni 2012. Tujuan utama terapi ini adalah pengembalian permukaan sendi ke posisi anatomis dengan fiksasi yang stabil dan pengembalian fungsi extremitas atas semaksimal mungkin. Metode: Penelitian ini berupa penelitian retrospektif yang dilakukan di poliklinik orthopaedi RSUP Dr M Djamil Padang pada bulan November-Desember 2012 pada pasien fraktur metafise distal radius intraartikuler usia muda yang mendapat tindakan operatif dibandingkan dengan kelompok non-operatif dengan penilaian klinis Quick DASH Score. Sampel yang digunakan sebanyak 30 orang dari 55 orang yang memenuhi kriteria inklusi. Hasil: Ada hubungan yang bermakna antara fungsi extremitas atas dengan penilaian Quick DASH Score antara tindakan operatif pada fraktur distal radius intraartikuler usia muda dengan tindakan non-operatif (p Fisher = 0,010. Tidak terdapat hubungan bermakna antara Quick DASH Score dengan jenis kelamin dan diagnosa kanan atau kiri. Pembahasan: Terdapat perbedaan yang bermakna antara pasien fraktur metafise distal radius intraartikuler pada usia muda yang mendapat tindakan operatif berupa ORIF dengan yang mendapatkan tindakan non-operatif berupa pemasangan Gips.Kata kunci: Fraktur Metafise Distal Radius, Tindakan Operatif dan Non Operatif, Quick Dash ScoreAbstractFracture metafise distal radius is fracture with second highest incident on old age besides a fracture in the pelvic area. In the Dr. M. Djamil Hospital found 122 from 612 cases fracture of radius from january 2011 to june 2012. The main purpose therapy is restore the joint in the surface position anatomically by fixation a stable and restore the function upper extremitas over their best. Method: This study is a retrospective conducted at the Orthopaedi clinic of Dr M

  9. [Case-control study on tibetan Baimai ointment (see symbol in text) for the treatment of wrist-dysfunction after distal radius fracture].

    Science.gov (United States)

    Zhang, Xing-ping; Xu, Gen-rong; Xu, Shan-qiang; Lu, Ze-ming; Huang, Lei

    2014-11-01

    To evaluate efficacy and safety of Baimai ointment (see symbol in text) in the treatment of wrist-dysfunction after distal radius fracture. From April, 2011 to June, 2012, 43 patients with distal radius fracture were treated with plaster fixation. All the patients were divided into two group: test group and control group. Twenty-one patients in test group and 22 in control group, and the baseline was balance (P > 0.05). The 21 patients in test group were treated with Baimai ointment (see symbol in text), fomentation, functional exercises. The 22 patients in control group were treated with placebo, fomentation, functional exercises. Foment affected side wrist with wet towel in 20 min before medication, with the temperature between 50 degrees C and 60 degrees C. Smear drugs uniformly in range of 3 cm in the vicinity of palm stripes after drying (about 3 g) and take functional exercises for the activities of wrist and hand. Continuous follow the program per 8 hours once and follow-up for 8 weeks. The Wrist's pain was assessed with VAS. The wrist's activities were measured with the protractor of orthopedic. Measure The grip strength was measured with dynamometer. The wrist's function were assessed with the table of Cooney. The test group had a significantly better results than those of control group in the extent of wrist's pain throughout the treatment (P 0.05). There were no drug adverse reactions occurred. Tibetan Baimai ointment (see symbol in text) has the treatment of wrist-dysfunction after distal radius fracture for external use, which can reduce the extent of wrist's pain, promote grip strength recovery in the middle and late of process, promote wrist's function recovery latterly, and safety for external use.

  10. Reabilitação das fraturas do rádio distal Rehabilitation of distal radius fractures

    Directory of Open Access Journals (Sweden)

    Patrícia Silva Hampe Barbosa

    2009-01-01

    Full Text Available O objetivo deste estudo foi avaliar a evidência do efeito e eleição da conduta terapêutica nas fraturas do rádio distal. A revisão sistemática utilizou as bases de dados PubMed, Lilacs, Pedro, Cochrane, Scielo, OTseeker, sem restrições de período de publicação, com as seguintes palavras chaves: fraturas do rádio, reabilitação, terapia ocupacional, fisioterapia, incluindo línguas inglesa, espanhola, francesa e portuguesa. Os estudos encontrados foram avaliados independentemente pelos dois autores utilizando critérios da escala PEDro. Estudos não experimentais foram incluídos em busca de esclarecimentos sobre a reabilitação. Foram encontrados 22 estudos, sendo 14 ensaios clínicos controlados randomizados (ECRs. Dentre eles, quatro compararam mobilização precoce com tratamento convencional apresentando evidência moderada a favor da primeira; sete confrontaram tratamento baseado em exercícios domiciliares com tratamento em consultório apontando evidência conflitiva (um deles também comprovou eficácia de mobilização acessória passiva; e três analisaram eficácia de procedimentos terapêuticos: campo eletromagnético pulsado, drenagem linfática, ultra-som, indicando evidências limitadas. Os nove estudos não experimentais encontrados não apresentaram informações suficientes sobre os questionamentos desta pesquisa. Observou-se uma tendência dos autores em utilizar os princípios gerais da reabilitação ao elaborar condutas terapêuticas, mas os procedimentos utilizados não estão bem atestados pela literatura.The aim of this study was to assess the evidence regarding the adoption and effectiveness of therapeutic procedures employed for rehabilitation of distal radius fractures. This systematic review used the following databases: PubMed, Lilacs, PEDro, Cochrane, Scielo and OTseeker, without time restrictions. The following keywords were searched for: distal radius fracture, rehabilitation, occupational therapy

  11. Radiological dorsal tilt analysis of AO type A, B, and C fractures of the distal radius treated conservatively or with extra-focal K-wire plus external fixateur

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Michael [University Medical Center Hamburg-Eppendorf, Department of Trauma, Hand and Reconstructive Surgery, Hamburg (Germany); Borders General Hospital, Department for Trauma and Orthopaedic Surgery, Melrose, Roxburghshire, Scotland (United Kingdom); Schroeder, Malte; Gruber-Rathmann, Michaela; Ruecker, Andreas H. [University Medical Center Hamburg-Eppendorf, Department of Trauma, Hand and Reconstructive Surgery, Hamburg (Germany); Kossow, Kai [Department of Medical Psychology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany)

    2012-09-15

    Fractures of the distal radius are amongst the most common injury patterns. The dorsal tilt represents an important co-factor determining functional outcome. The purpose of this study was to analyze the radiological dorsal tilt and identify critical time frames in conservative and operative treatment of distal radius fractures. Eighty-seven conservatively treated (hematoma block assisted reduction and splinting) and 37 operatively treated (reduction, extra-focal K-wire fixation, bridging external fixateur) AO type A, B, and C fractures of the distal radius in 124 females were retrospectively analyzed. The dorsal tilt at the initial, post-reduction, and 2 weeks post-reduction stages was correlated with the final radiographic outcome at 6 weeks. Mean initial dorsal tilt was 16.53 in the conservatively treated group and 26.76 in the operatively treated group. Mean dorsal tilt after 6 weeks showed significant differences from the mean initial dorsal tilt at time of presentation within both groups (both groups p < 0.000). No significant differences between the two groups were found after 6 weeks of treatment (p = 0.194) regardless of the underlying AO fracture type. Conservatively treated radius fractures showed a significantly higher slip rate within the first 2 weeks (primary slip rate), whereas the operative group presented a significantly higher slip rate between the 2-week and 6-week radiographic checks (secondary slip rate). In terms of dorsal tilt, conservative (cast immobilization) and operative (K-wire fixation plus external fixateur) treatment demonstrated no significant differences at the final radiographic examination (6 weeks) regardless of the underlying AO fracture type. Both treatment groups showed treatment-associated different primary and secondary slip rates, indicating a need for more frequent radiographic checks within these critical time frames. (orig.)

  12. WHAT IS THE BEST RADIOGRAPHIC VIEW FOR "DIE PUNCH" DISTAL RADIUS FRACTURES? A CADAVER MODEL STUDY.

    Science.gov (United States)

    Falcochio, Diego Figueira; Crepaldi, Bruno Eiras; Trindade, Christiano Augusto; da Costa, Antonio Carlos; Chakkour, Ivan

    2012-01-01

    the aim of this study is try to show the best view for distal radius fractures so called die-punch fractures. There has been used a human cadaver radius bone from the Salvador Arena Tissue Bank. This bone was cleaned up after removing the soft tissues and osteotomies created displaced lunate fossa fractures of 0, 1, 2, 3 and 5 mm. We have fixed this fragment with adhesive tape. Then the joint deviation were significantly increased with step-offs of 1 mm. Radiographs were then taken into 5 different positions: postero-anterior view, lateral view, oblique views and tangencial view for each of the deviations. The resulting lunate fossa depression in each X-ray film was analyzed by the AutoCAD 2010® software. The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. The pronated oblique view was the best to see the 2mm degrees and the oblique supinated view wasn't able to see the degrees between 1 and 2mm. The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees.

  13. WHAT IS THE BEST RADIOGRAPHIC VIEW FOR “DIE PUNCH” DISTAL RADIUS FRACTURES? A CADAVER MODEL STUDY

    Science.gov (United States)

    Falcochio, Diego Figueira; Crepaldi, Bruno Eiras; Trindade, Christiano Augusto; da Costa, Antonio Carlos; Chakkour, Ivan

    2015-01-01

    Objective: the aim of this study is try to show the best view for distal radius fractures so called die-punch fractures. Methods: There has been used a human cadaver radius bone from the Salvador Arena Tissue Bank. This bone was cleaned up after removing the soft tissues and osteotomies created displaced lunate fossa fractures of 0, 1, 2, 3 and 5 mm. We have fixed this fragment with adhesive tape. Then the joint deviation were significantly increased with step-offs of 1 mm. Radiographs were then taken into 5 different positions: postero-anterior view, lateral view, oblique views and tangencial view for each of the deviations. The resulting lunate fossa depression in each X-ray film was analyzed by the AutoCAD 2010® software. Results: The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. The pronated oblique view was the best to see the 2mm degrees and the oblique supinated view wasn't able to see the degrees between 1 and 2mm. Conclusion: The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. PMID:27027079

  14. Paediatric post-traumatic cortical defects of the distal radius

    International Nuclear Information System (INIS)

    Roach, Richard T.; Summers, Bruce N.; Cassar-Pullicino, Victor

    2002-01-01

    Paediatric post-traumatic cortical defects, although rare, are predominately seen affecting the distal radius following a greenstick or torus fracture. We review the literature and present a further two cases supported by CT and MRI. Images from an acute greenstick fracture are also presented to help understand the pathogenesis. Defects are typically solitary on plain radiographs and are usually noticed late, proximal to the site of compression. They are non-expansile in an otherwise healthy child. CT and MRI may reveal smaller multiple subperiosteal defects. Typical defects require no further management other than reassurance and advice that they may occasionally cause discomfort but resolve with time. (orig.)

  15. UK DRAFFT - A randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking-plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius

    Directory of Open Access Journals (Sweden)

    Brown Jaclyn

    2011-09-01

    Full Text Available Abstract Background Fractures of the distal radius are extremely common injuries in adults. However, the optimal management remains controversial. In general, fractures of the distal radius are treated non-operatively if the bone fragments can be held in anatomical alignment by a plaster cast or orthotic. However, if this is not possible, then operative fixation is required. There are several operative options but the two most common in the UK, are Kirschner-wire fixation (K-wires and volar plate fixation using fixed-angle screws (locking-plates. The primary aim of this trial is to determine if there is a difference in the Patient-Reported Wrist Evaluation one year following K-wire fixation versus locking-plate fixation for adult patients with a dorsally-displaced fracture of the distal radius. Methods/design All adult patients with an acute, dorsally-displaced fracture of the distal radius, requiring operative fixation are potentially eligible to take part in this study. A total of 390 consenting patients will be randomly allocated to either K-wire fixation or locking-plate fixation. The surgery will be performed in trauma units across the UK using the preferred technique of the treating surgeon. Data regarding wrist function, quality of life, complications and costs will be collected at six weeks and three, six and twelve months following the injury. The primary outcome measure will be wrist function with a parallel economic analysis. Discussion This pragmatic, multi-centre trial is due to deliver results in December 2013. Trial registration Current Controlled Trials ISRCTN31379280 UKCRN portfolio ID 8956

  16. Biomechanics of the Proximal Radius Following Drilling of the Bicipital Tuberosity to Mimic Cortical Button Distal Biceps Repair Technique.

    Science.gov (United States)

    Oak, Nikhil R; Lien, John R; Brunfeldt, Alexander; Lawton, Jeffrey N

    2018-05-01

    A fracture through the proximal radius is a theoretical concern after cortical button distal biceps fixation in an active patient. The permanent, nonossified cortical defect and medullary tunnel is at risk during a fall eliciting rotational and compressive forces. We hypothesized that during simulated torsion and compression, in comparison with unaltered specimens, the cortical button distal biceps repair model would have decreased torsional and compressive strength and would fracture in the vicinity of the bicipital tuberosity bone tunnel. Sixteen fourth-generation composite radius Sawbones models were used in this controlled laboratory study. A bone tunnel was created through the bicipital tuberosity to mimic the exact bone tunnel, 8 mm near cortex and 3.2 mm far cortex, made for the BicepsButton distal biceps tendon repair. The radius was then prepared and mounted on either a torsional or compression testing device and compared with undrilled control specimens. Compression tests resulted in average failure loads of 9015.2 N in controls versus 8253.25 N in drilled specimens ( P = .074). Torsional testing resulted in an average failure torque of 27.3 Nm in controls and 19.3 Nm in drilled specimens ( P = .024). Average fracture angle was 35.1° in controls versus 21.1° in drilled. Gross fracture patterns were similar in compression testing; however, in torsional testing all fractures occurred through the bone tunnel in the drilled group. There are weaknesses in the vicinity of the bone tunnel in the proximal radius during biomechanical stress testing which may not be clinically relevant in nature. In cortical button fixation, distal biceps repairs creates a permanent, nonossified cortical defect with tendon interposed in the bone tunnel, which can alter the biomechanical properties of the proximal radius during compressive and torsional loading.

  17. Open reduction and internal fixation versus casting for highly comminuted and intra-articular fractures of the distal radius (ORCHID): protocol for a randomized clinical multi-center trial.

    Science.gov (United States)

    Bartl, Christoph; Stengel, Dirk; Bruckner, Thomas; Rossion, Inga; Luntz, Steffen; Seiler, Christoph; Gebhard, Florian

    2011-03-22

    Fractures of the distal radius represent the most common fracture in elderly patients, and often indicate the onset of symptomatic osteoporosis. A variety of treatment options is available, including closed reduction and plaster casting, K-wire-stabilization, external fixation and open reduction and internal fixation (ORIF) with volar locked plating. The latter is widely promoted by clinicians and hardware manufacturers. Closed reduction and cast stabilization for six weeks is a simple, convenient, and ubiquitously available intervention. In contrast, ORIF requires hospitalization, but allows for functional rehabilitation.Given the lack of randomized controlled trials, it remains unclear whether ORIF leads to better functional outcomes one year after injury than closed reduction and casting. ORCHID (Open reduction and internal fixation versus casting for highly comminuted intra-articular fractures of the distal radius) is a pragmatic, randomized, multi-center, clinical trial with two parallel treatment arms. It is planned to include 504 patients in 15 participating centers throughout Germany over a three-year period. Patients are allocated by a central web-based randomization tool.The primary objective is to determine differences in the Short Form 36 (SF-36) Physical Component Score (PCS) between volar locked plating and closed reduction and casting of intraarticular, comminuted distal radius fractures in patients > 65 years of age one year after the fracture. Secondary outcomes include differences in other SF-36 dimensions, the EuroQol-5D questionnaire, the Disability of the Arm, Shoulder, and Hand (DASH) instrument. Also, the range of motion in the affected wrist, activities of daily living, complications (including secondary ORIF and revision surgery), as well as serious adverse events will be assessed. Data obtained during the trial will be used for later health-economic evaluations. The trial architecture involves a central statistical unit, an independent

  18. Teaching the Basics: Development and Validation of a Distal Radius Reduction and Casting Model.

    Science.gov (United States)

    Seeley, Mark A; Fabricant, Peter D; Lawrence, J Todd R

    2017-09-01

    Approximately one-third of reduced pediatric distal radius fractures redisplace, resulting in further treatment. Two major modifiable risk factors for loss of reduction are reduction adequacy and cast quality. Closed reduction and immobilization of distal radius fractures is an Accreditation Council for Graduate Medical Education residency milestone. Teaching and assessing competency could be improved with a life-like simulation training tool. Our goal was to develop and validate a realistic distal radius fracture reduction and casting simulator as determined by (1) a questionnaire regarding the "realism" of the model and (2) the quantitative assessments of reduction time, residual angulation, and displacement. A distal radius fracture model was created with radiopaque bony segments and articulating elbows and shoulders. Simulated periosteum and internal deforming forces required proper reduction and casting techniques to achieve and maintain reduction. The forces required were estimated through an iterative process through feedback from experienced clinicians. Embedded monofilaments allowed for quantitative assessment of residual displacement and angulation through the use of fluoroscopy. Subjects were asked to perform closed reduction and apply a long arm fiberglass cast. Primary performance variables assessed included reduction time, residual angulation, and displacement. Secondary performance variables consisted of number of fluoroscopic images, casting time, and cast index (defined as the ratio of the internal width of the forearm cast in the sagittal plane to the internal width in the coronal plane at the fracture site). Subject grading was performed by two blinded reviewers. Interrater reliability was nearly perfect across all measurements (intraclass correlation coefficient range, 0.94-0.99), thus disagreements in measurements were handled by averaging the assessed values. After completion the participants answered a Likert-based questionnaire regarding the

  19. Are distal radius fractures due to fragility or to falls? A consecutive case-control study of bone mineral density, tendency to fall, risk factors for osteoporosis, and health-related quality of life.

    Science.gov (United States)

    Nordvall, Helena; Glanberg-Persson, Gunhild; Lysholm, Jack

    2007-04-01

    A fracture of the distal radius is considered to indicate an increased risk of future fractures, especially a hip fracture. The main causes may be osteoporosis or a tendency to fall, separately or in combination. 93 women and 5 men with a recent radius fracture and the same number of controls were measured with a heel-DXL and asked to complete one questionnaire on their quality of life (SF-36), and one on risk factors. The mean T-score of the patients was -2.1, and for the controls it was -1.9 (p = 0.3). The patients aged over 64 years had a history of falling more often than the corresponding controls (p = 0.01), but there was no difference in T-score. By contrast, patients 45-64 years of age showed a non-significant, lower T-score (p = 0.09), but there was no difference concerning their history of falling. For all other risk factors, no differences were found between the patients and the controls. There were significant differences between the patients and the controls in some of the functions in the SF-36, due to the radius fracture. This study indicates that the underlying cause of a distal radius fracture may be different in patients aged 45-64 years and those who are more than 64 years old.

  20. Open reduction and internal fixation versus casting for highly comminuted and intra-articular fractures of the distal radius (ORCHID: protocol for a randomized clinical multi-center trial

    Directory of Open Access Journals (Sweden)

    Seiler Christoph

    2011-03-01

    Full Text Available Abstract Background Fractures of the distal radius represent the most common fracture in elderly patients, and often indicate the onset of symptomatic osteoporosis. A variety of treatment options is available, including closed reduction and plaster casting, K-wire-stabilization, external fixation and open reduction and internal fixation (ORIF with volar locked plating. The latter is widely promoted by clinicians and hardware manufacturers. Closed reduction and cast stabilization for six weeks is a simple, convenient, and ubiquitously available intervention. In contrast, ORIF requires hospitalization, but allows for functional rehabilitation. Given the lack of randomized controlled trials, it remains unclear whether ORIF leads to better functional outcomes one year after injury than closed reduction and casting. Methods/Design ORCHID (Open reduction and internal fixation versus casting for highly comminuted intra-articular fractures of the distal radius is a pragmatic, randomized, multi-center, clinical trial with two parallel treatment arms. It is planned to include 504 patients in 15 participating centers throughout Germany over a three-year period. Patients are allocated by a central web-based randomization tool. The primary objective is to determine differences in the Short Form 36 (SF-36 Physical Component Score (PCS between volar locked plating and closed reduction and casting of intraarticular, comminuted distal radius fractures in patients > 65 years of age one year after the fracture. Secondary outcomes include differences in other SF-36 dimensions, the EuroQol-5D questionnaire, the Disability of the Arm, Shoulder, and Hand (DASH instrument. Also, the range of motion in the affected wrist, activities of daily living, complications (including secondary ORIF and revision surgery, as well as serious adverse events will be assessed. Data obtained during the trial will be used for later health-economic evaluations. The trial architecture

  1. [Comparative study on the strength of different mechanisms of operation of multidirectionally angle-stable distal radius plates].

    Science.gov (United States)

    Rausch, S; Hoffmeier, K; Gueorguiev, B G; Klos, K; Gras, F; Hofmann, G O; Mückley, T

    2011-12-01

    Polyaxial angle-stable plating is thought to be particularly beneficial in the management of complex intra-articular fractures of the distal radius. The present study was performed to investigate the strength of polyaxial locking interfaces of distal radius plates. We tested the polyaxial interfaces of 3 different distal radius plates (2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate, Synthes, Palmar Classic, Königsee Implantate and VariAx Plate Stryker). The strength of 0° and 10° screw locking angle was obtained during static loading. The strength of Palmar Classic with a 0° locking angle is significantly the best of all tested systems. With a 10° locking angle there is no significant difference between Palmar Classic, Two column Plate and VariAx Plate. The strength of polyaxial interfaces differs between the tested systems. A reduction of ultimate strength is due to increases of screw locking angle. The design of polyaxial locking interfaces should be investigated in human bone models. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Study protocol: non-displaced distal radial fractures in adult patients: three weeks vs. five weeks of cast immobilization: a randomized trial.

    Science.gov (United States)

    Bentohami, Abdelali; de Korte, Niels; Sosef, Nico; Goslings, Johan Carel; Bijlsma, Taco; Schep, Niels

    2014-01-20

    Up to 30% of patients suffer from long-term functional restrictions following conservative treatment of distal radius fractures. Whether duration of cast immobilisation influences functional outcome remains unclear. The aim of the study is to evaluate whether the duration of immobilization of non or minimally displaced distal radial fractures can be safely reduced. We will compare three weeks of plaster cast immobilization with five weeks of plaster cast immobilization in adult patient with non or minimally displaced distal radial fractures. a prospective randomized clinical trial. adult (>18 years) (independent in activities of daily living) patients with a non/minimal displaced distal radius fracture (dorsal angulation 15°, ulnar positive variance immobilization versus five weeks of plaster cast immobilization.Main study parameters: primary outcome parameters: Patient related wrist evaluation (PRWE) Quick Disability of Arm, Shoulder and Hand (QUICKDASH) score after a one year follow-up, and secondary parameters: range of motion, pain level (VAS) and complications. The expectation of this study is that shorter duration of plaster cast immobilisation is beneficial for the patient with a distal radius fracture. This risk of specific complications is low and generally similar in both treatment options. Moreover, the burden of the study is not much higher compared to standard treatment. Follow-up is standardized according to current trauma guidelines. Literature indicates that both treatment options from the study are accepted for displaced distal radius fractures. No clear advantage for one treatment options is found at present in the literature, although there is no level I evidence present. This trial will provide level-1 evidence for the comparison of consolidation and functional outcome between two treatment options for non-displaced distal radial fractures. The gathered data may support the development of a clinical guideline for conservative treatment of

  3. Full title: Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures.

    Science.gov (United States)

    Mugnai, Raffaele; Tarallo, Luigi; Capra, Francesco; Catani, Fabio

    2018-05-25

    As the popularity of volar locked plate fixation for distal radius fractures has increased, so have the number and variety of implants, including variations in plate design, the size and angle of the screws, the locking screw mechanism, and the material of the plates. carbon-fiber reinforced polyetheretherketone (CFR-PEEK) plate features similar biomechanical properties to metallic plates, representing, therefore, an optimal alternative for the treatment of distal radius fractures. three different materials-composed plates were evaluated: stainless steel volar lateral column (Zimmer); titanium DVR (Hand Innovations); CFR-PEEK DiPHOS-RM (Lima Corporate). Six plates for each type were implanted in sawbones and an extra-articular rectangular osteotomy was created. Three plates for each material were tested for load to failure and bending stiffness in axial compression. Moreover, 3 constructs for each plate were evaluated after dynamically loading for 6000 cycles of fatigue. the mean bending stiffness pre-fatigue was significantly higher for the stainless steel plate. The titanium plate yielded the higher load to failure both pre and post fatigue. After cyclic loading, the bending stiffness increased by a mean of 24% for the stainless steel plate; 33% for the titanium; and 17% for the CFR-PEEK plate. The mean load to failure post-fatigue increased by a mean of 10% for the stainless steel and 14% for CFR-PEEK plates, whereas it decreased (-16%) for the titanium plate. Statistical analysis between groups reported significant values (p plastic deformation, and lower load to failure. N/A. Copyright © 2018. Published by Elsevier Masson SAS.

  4. Ipsilateral dislocation of the radial head associated with fracture of distal end of the radius: a case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Gupta Vinay

    2013-06-01

    Full Text Available 【Abstract】Dislocation of the radial head in adults is uncommon. A simultaneous dislocation of the radial head and fracture of the ipsilateral distal end of radius with no other associated injuries is extremely rare. As far as we know, such an injury after an unusual mode of injury has been seldom reported in the English literature. We report such a case without any associated injuries or comorbidity. Closed reduction was performed within two hours after injury and results were satisfactory. Immobilisation was continued for 3 weeks. Gradual mobilisation was started after removal of the plaster under the supervision of a physiotherapist. At 6 months’ follow-up, the patient had no residual pain at the elbow with full flexion & extension. Almost full supination with a restriction of last 10 degrees of pronation was achieved. There was no evidence of instability of the elbow. Key words: Radial heads; Dislocations; Radius fractures

  5. A prospective study on the effectiveness of cotton versus waterproof cast padding in maintaining the reduction of pediatric distal forearm fractures.

    Science.gov (United States)

    Robert, Christopher E; Jiang, Jimmy J; Khoury, Joseph G

    2011-03-01

    Distal forearm fractures, one of the most common fractures seen in the pediatric population, are regularly treated by closed reduction and casting. Our study investigates the effectiveness of Gore-Tex-lined casting in maintaining the reduction of 100% displaced distal forearm fractures compared with traditional cotton-lined casts. We screened all patients from February 2007 to July 2009 who presented to Children's Hospital in Birmingham, AL with a distal radius fracture. Only patients with 100% displaced distal radius fractures were eligible to be assigned to either the cotton-lined or Gore-Tex-lined cast groups. Power analysis was performed to identify an adequate patient sample size. The mean maximum change between initial post-reduction x-rays and follow-up x-rays for anterior-posterior (AP) angulation, AP displacement, lateral angulation, and lateral displacement of the radius were calculated for both cotton and Gore-Tex groups. The rate of subsequent intervention and/or unacceptable results for each group was also analyzed. Seven hundred and twenty-two patients were treated with distal radius fractures at our hospital with 59 patients eligible for inclusion in our study. Thirty-six of our patients were treated with cotton-lined casts, and 23 patients were treated with Gore-Tex-lined cast. The mean maximum change in AP angulation, AP displacement, lateral angulation, and lateral displacement of the radius after initial reduction was 9.2 degrees, 6.9%, 13.9 degrees, and 13.6%, respectively, for the cotton-lined cast group and 7.7 degrees, 6.1%, 14.6 degrees, and 9.6%, respectively, for the Gore-Tex-lined cast group. There were no statistical differences between the means of the 4 measurements (P=0.33, 0.69, 0.73, and 0.10, respectively). There were also no significant differences between groups for final AP and lateral angulation and displacement. Subgroup analysis showed no significant differences in all measurements between cotton and Gore-Tex groups. Gore

  6. Recommendation for measuring clinical outcome in distal radius fractures: a core set of domains for standardized reporting in clinical practice and research.

    Science.gov (United States)

    Goldhahn, Jörg; Beaton, Dorcas; Ladd, Amy; Macdermid, Joy; Hoang-Kim, Amy

    2014-02-01

    Lack of standardization of outcome measurement has hampered an evidence-based approach to clinical practice and research. We adopted a process of reviewing evidence on current use of measures and appropriate theoretical frameworks for health and disability to inform a consensus process that was focused on deriving the minimal set of core domains in distal radius fracture. We agreed on the following seven core recommendations: (1) pain and function were regarded as the primary domains, (2) very brief measures were needed for routine administration in clinical practice, (3) these brief measures could be augmented by additional measures that provide more detail or address additional domains for clinical research, (4) measurement of pain should include measures of both intensity and frequency as core attributes, (5) a numeric pain scale, e.g. visual analogue scale or visual numeric scale or the pain subscale of the patient-reported wrist evaluation (PRWE) questionnaires were identified as reliable, valid and feasible measures to measure these concepts, (6) for function, either the Quick Disability of the arm, shoulder and hand questionnaire or PRWE-function subscale was identified as reliable, valid and feasible measures, and (7) a measure of participation and treatment complications should be considered core outcomes for both clinical practice and research. We used a sound methodological approach to form a comprehensive foundation of content for outcomes in the area of distal radius fractures. We recommend the use of symptom and function as separate domains in the ICF core set in clinical research or practice for patients with wrist fracture. Further research is needed to provide more definitive measurement properties of measures across all domains.

  7. It is not just comfort: waterproof casting increases physical functioning in children with minimally angulated distal radius fractures.

    Science.gov (United States)

    Silva, Mauricio; Avoian, Tigran; Warnock, Robert Sean; Sadlik, Gal; Ebramzadeh, Edward

    2017-09-01

    Waterproof casting has been reported to increase patient comfort and satisfaction, and decrease skin irritation. There are no available data on the influence of waterproof casting materials on physical function in pediatric patients. Our aim was to determine whether the use of waterproof casting would result in faster recovery of physical function while maintaining similar clinical outcomes as those obtained with nonwaterproof materials. Twenty-six children with nonangulated or minimally angulated distal radius fractures were assigned randomly to initially receive a short-arm cast made of one of two optional materials: a hybrid mesh material with a waterproof lining or fiberglass with a nonwaterproof skin protector. Two weeks later, the initial cast was removed and replaced with a short-arm cast made of the alternative option. We compared the rate of fracture displacement, physical function, pain, skin changes, itchiness, and patient satisfaction. No evidence of displacement was found in either group. The mean Activities Scale for Kids - Performance (ASK-P) (physical function) score was 10% higher during the period of time when a waterproof cast was used (P=0.04). When a waterproof cast was used during the first 2 weeks of treatment, the mean total ASK-P scores were 23% higher than that when a nonwaterproof one was used during the same period of time (P=0.003). Patients who received a waterproof cast as the initial treatment reported lower functional scores overall and in almost every domain of the ASK-P once they were in a nonwaterproof one; similarly, those who received a nonwaterproof cast as the initial treatment reported higher functional scores overall and in every domain of the ASK-P once they were in a waterproof cast. Compared with a nonwaterproof cast, the use of waterproof casting resulted in comparable levels of pain, itchiness, skin irritability, and overall patient satisfaction. The results of this randomized, cross-over trial suggest that the use of

  8. [Distal clavicle fracture].

    Science.gov (United States)

    Seppel, G; Lenich, A; Imhoff, A B

    2014-06-01

    Reposition and fixation of unstable distal clavicle fractures with a low profile locking plate (Acumed, Hempshire, UK) in conjunction with a button/suture augmentation cerclage (DogBone/FibreTape, Arthrex, Naples, FL, USA). Unstable fractures of the distal clavicle (Jäger and Breitner IIA) in adults. Unstable fractures of the distal clavicle (Jäger and Breitner IV) in children. Distal clavicle fractures (Jäger and Breitner I, IIB or III) with marked dislocation, injury of nerves and vessels, or high functional demand. Patients in poor general condition. Fractures of the distal clavicle (Jäger and Breitner I, IIB or III) without marked dislocation or vertical instability. Local soft-tissue infection. Combination procedure: Initially the lateral part of the clavicle is exposed by a 4 cm skin incision. After reduction of the fracture, stabilization is performed with a low profile locking distal clavicle plate. Using a special guiding device, a transclavicular-transcoracoidal hole is drilled under arthroscopic view. Additional vertical stabilization is arthroscopically achieved by shuttling the DogBone/FibreTape cerclage from the lateral portal cranially through the clavicular plate. The two ends of the FibreTape cerclage are brought cranially via adjacent holes of the locking plate while the DogBone button is placed under the coracoid process. Thus, plate bridging is achieved. Finally reduction is performed and the cerclage is secured by surgical knotting. Use of an arm sling for 6 weeks. Due to the fact that the described technique is a relatively new procedure, long-term results are lacking. In the short term, patients postoperatively report high subjective satisfaction without persistent pain.

  9. Acute flexor tendon injury following midshaft radius and ulna fractures in a paediatric patient

    Directory of Open Access Journals (Sweden)

    James Williams

    2018-06-01

    Full Text Available Delayed rupture of the extensor and flexor tendons are recognised complications of distal radius fractures. However, acute flexor tendon rupture in the context of forearm fractures is rare. A twelve-year-old female sustained midshaft fractures of the radius and ulna. Intra-operatively the flexor pollicis longus (FPL was found to be stripped from its musculotendinous junction at the level of the fracture fragment. The ruptured tendon was repaired using a modified Krackow technique at the time of fracture fixation. The repair was protected in plaster of Paris prior to referral to the paediatric hand clinic. The patient made a full recovery. Flexor tendon injury is a rare but potentially devastating consequence of acute forearm fractures. High energy trauma, significant volar angulation of the fracture fragment and clinical signs of flexor tendon injury should raise suspicion of this injury. A high index of suspicion in conjunction with repeat clinical examination of flexor tendon function should be performed before opting for closed management or intramedullary nailing in paediatric patients. Keywords: Acute, Flexor, Tendon, Fracture, Radius, Paediatric

  10. Stress fractures of the humerus, radius, and tibia in horses: clinical features and radiographic and/or scintigraphic appearance

    International Nuclear Information System (INIS)

    Mackey, V.S.; Trout, D.R.; Meagher, D.M.; Hornof, W.J.

    1987-01-01

    The medical records, radiographic and nuclear scintigraphic findings of 26 racing horses with 27 stress fracture episodes of the humerus, radius, or tibia were reviewed. The purposes of this study were to describe the radiographic and/or scintigraphic features of stress fractures of the humerus, radius, or tibia, and to evaluate the signalment and history of horses in which stress fracture occurred. Stress fractures of the three long bones examined were primarily seen in 2- and 3-year-old male Thoroughbred horses; commonly, the onset of lameness was immediately following training gallops or racing. There were 13 humeral stress fracture episodes in 12 horses. Ten were in the proximal caudolateral cortex, and three were in the distal craniomedial cortex. Radical stress fractures were seen in three horses, all in the midshaft radius. Tibial stress fractures were diagnosed in 11 horses. They were located in the proximal lateral tibia in six horses, the distal caudolateral tibia in three horses, and the midshaft tibia in three horses. Fifteen stress fractures were diagnosed with radiography alone, one was diagnosed with scintigraphy alone, nine were diagnosed with radiographs and scintigraphy, and, in two horses, radiographs were negative, but the scintigraphic findings were consistent with stress fracture

  11. New quantitative ultrasound techniques for bone analysis at the distal radius in hip fracture cases: differences between femoral neck and trochanteric fractures.

    Science.gov (United States)

    Horii, Motoyuki; Fujiwara, Hiroyoshi; Sakai, Ryo; Sawada, Koshiro; Mikami, Yasuo; Toyama, Syogo; Ozaki, Etsuko; Kuriyama, Nagato; Kurokawa, Masao; Kubo, Toshikazu

    2017-01-01

    Ample evidence on etiological and pathological differences between femoral neck and trochanteric fracture cases suggests the possibility of individualized treatment. There are many issues related to areal bone mineral density and other quantitative computed tomography parameters of the proximal femur. Although osteoporosis is a systemic problem, little has been reported regarding differences in bone structural parameters, including bone mineral density, between them in regions other than the proximal femur. Participants were consecutive female patients >50 years of age admitted to the Saiseikai Suita Hospital (Osaka prefecture, Japan) for their first hip fracture between January 2012 and September 2014. Cortical thickness (CoTh, mm), volumetric trabecular bone mineral density (TBD, mg/cm 3 ), and elastic modulus of trabecular bone (EMTb, GPa) were obtained as the new QUS parameters using the LD-100 system (Oyo Electric, Kyoto, Japan). The mean values of these parameters were compared between femoral neck and trochanteric fracture cases. In addition, correlations between age and each QUS parameter were investigated for each fracture type. A receiver operating characteristic (ROC) curve analysis was performed to examine the degree of effect each parameter on the fracture types. The area under the curve (AUC) for each parameter was compared to the AUC for age. There were 63 cases of femoral neck fracture (mean age, 78.2 years) and 37 cases of trochanteric fracture (mean age, 85.9 years). Mean TBD and EMTb were significantly higher for femoral neck fractures. There were significant negative correlations between QUS parameters and age for femoral neck fractures (P fractures were above those for trochanteric fractures for TBD and EMTb. AUCs were 0.72 for age, and 0.61, 0.65, and 0.65 for CoTh, TBD, and EMTb, respectively. The new QUS parameters indicated that TR fracture cases were more osteoporotic than were FN fracture cases, even at the distal radius. There might be

  12. Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study.

    Science.gov (United States)

    de Jong, Joost J A; Lataster, Arno; van Rietbergen, Bert; Arts, Jacobus J; Geusens, Piet P; van den Bergh, Joop P W; Willems, Paul C

    2017-02-27

    Carbon-fiber-reinforced poly-ether-ether-ketone (CFR-PEEK) has superior radiolucency compared to other orthopedic implant materials, e.g. titanium or stainless steel, thus allowing metal-artifact-free postoperative monitoring by computed tomography (CT). Recently, high-resolution peripheral quantitative CT (HRpQCT) proved to be a promising technique to monitor the recovery of volumetric bone mineral density (vBMD), micro-architecture and biomechanical parameters in stable conservatively treated distal radius fractures. When using HRpQCT to monitor unstable distal radius fractures that require volar distal radius plating for fixation, radiolucent CFR-PEEK plates may be a better alternative to currently used titanium plates to allow for reliable assessment. In this pilot study, we assessed the effect of a volar distal radius plate made from CFR-PEEK on bone parameters obtained from HRpQCT in comparison to two titanium plates. Plates were instrumented in separate cadaveric human fore-arms (n = 3). After instrumentation and after removal of the plates duplicate HRpQCT scans were made of the region covered by the plate. HRpQCT images were visually checked for artifacts. vBMD, micro-architectural and biomechanical parameters were calculated, and compared between the uninstrumented and instrumented radii. No visible image artifacts were observed in the CFR-PEEK plate instrumented radius, and errors in bone parameters ranged from -3.2 to 2.6%. In the radii instrumented with the titanium plates, severe image artifacts were observed and errors in bone parameters ranged between -30.2 and 67.0%. We recommend using CFR-PEEK plates in longitudinal in vivo studies that monitor the healing process of unstable distal radius fractures treated operatively by plating or bone graft ingrowth.

  13. A biomechanical comparison of four fixed-angle dorsal plates in a finite element model of dorsally-unstable radius fracture.

    Science.gov (United States)

    Knežević, Josip; Kodvanj, Janoš; Čukelj, Fabijan; Pamuković, Frane; Pavić, Arsen

    2017-11-01

    To compare the finite element models of two different composite radius fracture patterns, reduced and stabilised with four different fixed-angle dorsal plates during axial, dorsal and volar loading conditions. Eight different plastic models representing four AO/ASIF type 23-A3 distal radius fractures and four AO/ASIF 23-C2 distal radius fractures were obtained and fixed each with 1 of 4 methods: a standard dorsal non-anatomical fixed angle T-plate (3.5mm Dorsal T-plate, Synthes), anatomical fixed-angle double plates (2.4mm LCP Dorsal Distal Radius, Synthes), anatomical fixed angle T-plate (2.4mm Acu-Loc Dorsal Plate, Acumed) or anatomical variable-angle dorsal T-plate (3.5mm, Dorsal Plate, Zrinski). Composite radius with plate and screws were scanned with a 3D optical scanner and later processed in Abaqus Software to generate the finite element model. All models were axially loaded at 3 points (centrally, volarly and dorsally) with 50 N forces to avoid the appearance of plastic deformations of the models. Total displacements at the end of the bone and the stresses in the bones and plates were determined and compared. Maximal von Mises stress in bone for 3-part fracture models was very similar to that in 2-part fracture models. The biggest difference between models and the largest displacements were seen during volar loading. The stresses in all models were the highest above the fracture gap. The best performance in all parameters tested was with the Zrinski plate and the most modest results were with the Synthes T-plate. There was no significant difference between 2-part (AO/ASIF type 23-A3) and 3-part (AO/ASIF 23-C2) fracture models. Maximal stresses in the plates appeared above the fracture gap; therefore, it is worth considering the development of plates without screw holes above the gap. © 2017 Elsevier Ltd. All rights reserved.

  14. Fracture configurations of the equine radius and tibia after a simulated kick

    OpenAIRE

    Fürst, Anton; Oswald, Susanne E; Jäggin, S; Piskoty, G; Michel, S; Auer, Jörg A

    2008-01-01

    The objective of this postmortem study was to determine the fracture configurations of the equine radius and tibia after a simulated kick. Fracture configurations of 35 radii and 36 tibiae from 19 adult horses were evaluated after a simulated kick in an experimental exvivo study. The bones were dissected, the proximal and distal ends were embedded in resin, fixed horizontally and preloaded in compression, and a steel impactor, designed to simulate a shod equine hoof, was dropped from a height...

  15. Patient-specific distal radius locking plate for fixation and accurate 3D positioning in corrective osteotomy.

    Science.gov (United States)

    Dobbe, J G G; Vroemen, J C; Strackee, S D; Streekstra, G J

    2014-11-01

    Preoperative three-dimensional planning methods have been described extensively. However, transferring the virtual plan to the patient is often challenging. In this report, we describe the management of a severely malunited distal radius fracture using a patient-specific plate for accurate spatial positioning and fixation. Twenty months postoperatively the patient shows almost painless reconstruction and a nearly normal range of motion.

  16. Complications and functional outcome after internal fixation of dorsally displaced distal radial fractures

    DEFF Research Database (Denmark)

    Bove, Jeppe; Viberg, Bjarke; Wied Greisen, Pernille

    Background: Recently there has been an increasing interest in open reduction and internal fixation of distal radius fractures. Even so further studies are still needed. Purpose: To document the functional outcome and identify complica- tions among patients treated with a volar locking plate (DVR...

  17. Incidence of Treatment for Infection of Buried Versus Exposed Kirschner Wires in Phalangeal, Metacarpal, and Distal Radial Fractures.

    Science.gov (United States)

    Ridley, Taylor J; Freking, Will; Erickson, Lauren O; Ward, Christina Marie

    2017-07-01

    To determine whether there is a difference in the incidence of infection between exposed and buried K-wires when used to treat phalangeal, metacarpal, and distal radius fractures. We conducted a retrospective review identifying all patients aged greater than 16 years who underwent fixation of phalangeal, metacarpal, or distal radius fractures with K-wires between 2007 and 2015. We recorded patient demographic data, fracture location, number of K-wires used, whether K-wires were buried or left exposed, and duration of K-wire placement. A total of 695 patients met inclusion criteria. Surgeons buried K-wires in 207 patients and left K-wires exposed in 488. Infections occurred more frequently in exposed K-wire cases than in buried K-wire ones. Subgroup analysis based on fracture location revealed a significantly increased risk of being treated for infection when exposed K-wires were used for metacarpal fractures. Patients with exposed K-wires for fixation of phalangeal, metacarpal, or distal radius fractures were more likely to be treated for a pin-site infection than those with K-wires buried beneath the skin. Metacarpal fractures treated with exposed K-wires were 2 times more likely to be treated for a pin-site infection (17.6% of exposed K wire cases vs 8.7% of buried K wire cases). Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  18. Evaluation of sarcopenia in patients with distal radius fractures.

    Science.gov (United States)

    Roh, Young Hak; Koh, Young Do; Noh, Jung Ho; Gong, Hyun Sik; Baek, Goo Hyun

    2017-12-01

    Sarcopenia is more prevalent in patients with distal radius fracture (DRF) than in age- and sex-matched controls. Lower appendicular mass index in men and weaker grip strength in both men and women increase the likelihood of DRF. Sarcopenia is a core component of physical frailty that predisposes older people to falls and negatively impacts the activities of daily living. The objectives of this study were to compare the prevalence of sarcopenia in patients with DRF with that in age- and sex-matched controls without DRF; and evaluate the association between sarcopenia and the occurrence of DRF. We prospectively recruited 132 patients over 50 years of age who sustained DRF due to fall and 132 age- and sex-matched controls without DRF. A definition of sarcopenia was based on the consensus of the Asian Working Group for Sarcopenia. Sarcopenic components including appendicular lean body mass, grip strength, and gait speed were compared between the two groups. Other factors assessed for the occurrence of DRF were age, gender, body mass index (BMI), lumbar, and hip bone mineral density (BMD) values. A conditional logistic regression analysis was conducted to evaluate the associations between sarcopenia and the occurrence of DRF. A total of 39 (30%) of 132 DRF patients were sarcopenic, whereas 23 (17%) of the 132 controls were within the sarcopenic criteria (p = 0.048). The patient group had significantly lower lean body mass and weaker grip strength than those of the control group. However, there was no significant difference in gait speed between the two groups. According to regression analysis, lower appendicular mass index in men was associated with an increased incidence of DRF (odds ratio [OR] = 0.84, 95% confidence interval [CI] = 0.72, 0.95) while weaker grip strength and lower total hip BMD values were associated with the occurrence of DRF in both men (OR = 0.77, 95% CI = 0.63, 0.92; and OR = 0.79, 95% CI = 0.64, 0.94, respectively) and women (OR

  19. Risk Factors Associated With Survival to Hospital Discharge of 54 Horses With Fractures of the Radius.

    Science.gov (United States)

    Stewart, Suzanne; Richardson, Dean; Boston, Ray; Schaer, Thomas P

    2015-11-01

    To determine (1) survival to discharge of horses with radial fractures (excluding osteochondral fragmentation of the distal aspect of the radius and stress fractures); and (2) risk factors affecting survival to hospital discharge in conservative and surgically managed fractures. Case series. Horses (n = 54). Medical records (1990-June 2012) and radiographs of horses admitted with radial fracture were reviewed. Horses with osteochondral fragmentation of the distal aspect of the radius or stress fractures were excluded. Evaluated risk factors were age, fracture configuration, surgical repair method, surgical duration, hospitalization time, implant failure rate, and surgical site infection (SSI) rate. Of 54 horses, overall survival to discharge was 50%. Thirteen (24%) were euthanatized on admission because of (1) fracture severity; (2) presence of an open fracture; or (3) financial constraints. Fourteen (26%) horses with minimally displaced incomplete fractures were conservatively managed and 12 (86%) survived to discharge. Twenty-seven (50%) horses had surgical treatment by open reduction and internal fixation (ORIF) and 15 (56%) survived to hospital discharge. Open fractures were significantly more likely to develop SSI (P = .008), which also resulted in a 17-fold increase in implant failure (P horses with an open fracture did not survive to discharge. Outcome was also adversely affected by age (P 168 minutes (P fractures is good. Young horses have a good prognosis survival to discharge for ORIF, whereas ORIF in adult horses has a poor prognosis and SSI strongly correlates with catastrophic implant failure. © Copyright 2015 by The American College of Veterinary Surgeons.

  20. Rate of Improvement following Volar Plate Open Reduction and Internal Fixation of Distal Radius Fractures

    Directory of Open Access Journals (Sweden)

    Chris Dillingham

    2011-01-01

    Full Text Available Purpose. To determine recovery timeline of unstable distal radius fractures treated by open reduction and internal fixation with a locking volar plate. Methods. Data was collected prospectively on a consecutive series of twenty-seven patients during routine post-operative visits at 2 and 6 weeks, and 3, 6, 12 and 24 months. Range of motion measures and grip strength for both wrists were recorded. Results. Greatest gains were made within the first 3 months after surgery. Supination and pronation returned more quickly than flexion or extension, with supination and pronation both at 92% of the uninjured wrist at 3 months. Only flexion improved significantly between 3 and 6 months. All wrist motions showed some improvement until 1 year. Grip strength returned to 94% of the uninjured wrist by 12 months. Conclusions. Range of motion improvement will be greatest between 2 weeks and 3 months, with improvement continuing until 12 months. Grip strength should return to near normal by one year. Function and pain will improve, but not return to normal by the end of 12 months. Clinical Relevance. These results provide the surgeon with information that can be shared with patients on the anticipated timeline for normal recovery of function and strength.

  1. Distal radius fracture arthroscopic intraarticular displacement measurement after open reduction and internal fixation from a volar approach.

    Science.gov (United States)

    Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryotaro; Katayama, Takeshi; Akahane, Manabu

    2010-07-01

    The purpose of this study was to assess articular surface reduction arthroscopically after volar locked-plate fixation of distal radius fractures (DRFs) via fluoroscopyguided open reduction/internal fixation. We also aimed to develop preoperative radiographic criteria to help assist in determining which DRFs may need arthroscopic evaluation. A total of 31 consecutive patients with DRF were prospectively enrolled. Posteroanterior (PA) and lateral radiographs as well as axial, coronal, and sagittal CT scans were obtained just after attempted reduction of the DRF. The widest articular displacement at the radiocarpal joint surface of the distal radius (preopD) was then measured using a digital radiography imaging system. The DRF was reduced under fluoroscopy, and a volar locked plate was applied. The degree of residual articular displacement was then measured arthroscopically, and the maximum displacement (postopD) was measured with a calibrated probe. Of the 31 patients, 7 had an arthroscopically assessed maximum postopD of > or = 2 mm after internal fixation. The correlation coefficients between each preopD and postopD of all radiographs and CTs were statistically significant. The cutoff values were 0.5 mm for PA radiographs, 2.10 mm for lateral radiographs, 2.15 mm for axial CT scans, 3.15 mm for coronal CT scans, and 1.20 mm for sagittal CT scans. All cutoff values for PA and lateral radiographs and for axial, coronal, and sagittal CT scans were unsuitable as screening criteria for arthroscopic reduction of DRF because of their low sensitivities and specificities. The cutoff value of the new preopD (the sum of the preopDs determined by lateral radiography and coronal CT scan) was 5.80 mm, and its sensitivity and specificity were 100% and 83.3%, respectively. Because a new preopD cutoff value of 5.80 mm is a good indicator for residual articular displacement after internal fixation of >2 mm, it is also a good indicator for the need for arthroscopic evaluation after

  2. Distal radius fracture arthroscopic intraarticular displacement measurement after open reduction and internal fixation from a volar approach

    International Nuclear Information System (INIS)

    Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryotaro; Katayama, Takeshi; Akahane, Manabu

    2010-01-01

    The purpose of this study was to assess articular surface reduction arthroscopically after volar locked-plate fixation of distal radius fractures (DRFs) via fluoroscopy-guided open reduction/internal fixation. We also aimed to develop preoperative radiographic criteria to help assist in determining which DRFs may need arthroscopic evaluation. A total of 31 consecutive patients with DRF were prospectively enrolled. Posteroanterior (PA) and lateral radiographs as well as axial, coronal, and sagittal CT scans were obtained just after attempted reduction of the DRF. The widest articular displacement at the radiocarpal joint surface of the distal radius (preopD) was then measured using a digital radiography imaging system. The DRF was reduced under fluoroscopy, and a volar locked plate was applied. The degree of residual articular displacement was then measured arthroscopically, and the maximum displacement (postopD) was measured with a calibrated probe. Of the 31 patients, 7 had an arthroscopically assessed maximum postopD of ≥2 mm after internal fixation. The correlation coefficients between each preopD and postopD of all radiographs and CTs were statistically significant. The cutoff values were 0.5 mm for PA radiographs, 2.10 mm for lateral radiographs, 2.15 mm for axial CT scans, 3.15 mm for coronal CT scans, and 1.20 mm for sagittal CT scans. All cutoff values for PA and lateral radiographs and for axial, coronal, and sagittal CT scans were unsuitable as screening criteria for arthroscopic reduction of DRF because of their low sensitivities and specificities. The cutoff value of the new preopD (the sum of the preopDs determined by lateral radiography and coronal CT scan) was 5.80 mm, and its sensitivity and specificity were 100% and 83.3%, respectively. Because a new preopD cutoff value of 5.80 mm is a good indicator for residual articular displacement after internal fixation of >2 mm, it is also a good indicator for the need for arthroscopic evaluation after

  3. Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol.

    Science.gov (United States)

    Raduan Neto, Jorge; de Moraes, Vinicius Ynoe; Gomes Dos Santos, João B; Faloppa, Flávio; Belloti, João Carlos

    2014-03-05

    Various treatments are available for reducible unstable fractures of the distal radius, such as closed reduction combined with fixation by external fixator (EF), and rigid internal fixation using a locked volar plate (VP). Although there are studies comparing these methods, there is no conclusive evidence indicating which treatment is best. The hypothesis of this study is that surgical treatment with a VP is more effective than EF from the standpoint of functional outcome (patient-reported). The study is randomized clinical trial with parallel groups and a blinded evaluator and involves the surgical interventions EF and VP. Patients will be randomly assigned (assignment ratio 1:1) using sealed opaque envelopes. This trial will include consecutive adult patients with an acute (up to 15 days) displaced, unstable fracture of the distal end of the radius of type A2, A3, C1, C2 or C3 by the Arbeitsgemeinschaft für Osteosynthesefragen-Association for the Study of Internal Fixation classification and type II or type III by the IDEAL32 classification, without previous surgical treatments of the wrist. The surgical intervention assigned will be performed by three surgical specialists familiar with the techniques described. Evaluations will be performed at 2, and 8 weeks, 3, 6 and 12 months, with the primary outcomes being measured by the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and measurement of pain (Visual Analog Pain Scale and digital algometer). Secondary outcomes will include radiographic parameters, objective functional evaluation (goniometry and dynamometry), and the rate of complications and method failure according to the intention-to-treat principle. Final postoperative evaluations (6 and 12 months) will be performed by independent blinded evaluators. For the Student's t-test, a difference of 10 points in the DASH score, with a 95% confidence interval, a statistical power of 80%, and 20% sampling error results in 36 patients per group

  4. [Clinical randomized controlled trial on ultrashort wave and magnetic therapy for the treatment of early stage distal radius fractures].

    Science.gov (United States)

    Wang, Guan-Jie; Liu, Jia

    2012-07-01

    To explore the effect of application of ultrashort wave and magnetic therapy instrument on the swelling regression in distal radius fractures treated by splint external fixation in initial stage. From March 2007 to May 2010,90 patients with distal radial fracture were treated by manual reduction and splint external fixation. After manual reduction and small splints external fixation, these patients were randomly divided into electrical physical therapy group, western medicine group and the control group by the order of calling number, with 30 cases each group. In control group, there were 9 males and 21 females with an average age of (61.29 +/- 1.97) years, the patients raised and exercise the limb and fingers only. The other two groups also carried out this treatment. In electrical physical therapy group, there were 9 males and 21 females with an average age of (62.37 +/- 2.48) years, the patients were treated with ultrashort wave and magnetic therapy instrument for early intervention, once a day, 5 days for a course of treatment and three cycle were operated. In western medicine group,there were 8 males and 22 females with an average age of (60.12 +/- 2.87) years, the patients were injected with beta-aescin (20 mg, intravenous injection,once a day) for 5 days, followed by Danshen injection (20 ml, intravenous injection, once a day) for 10 days. The limb swelling of patients were assessed every day for 20 days after manual reduction and small splints external fixation. The time of swelling regression in electrical physical therapy group, western medicine group and the control group were respectively (9.62 +/- 3.32), (10.05 +/- 3.05) and (14.57 +/- 2.93) days. Both of that in electrical physical therapy group and western medicine group were shorter than that in the control group (P0.05). The effective rate of swelling regression in electrical physical therapy group, western medicine group and the control group were 86.67%, 80.00%, 46.66% respectively. There was no

  5. Computer-assisted versus non-computer-assisted preoperative planning of corrective osteotomy for extra-articular distal radius malunions: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Stockmans Filip

    2010-12-01

    Full Text Available Abstract Background Malunion is the most common complication of distal radius fracture. It has previously been demonstrated that there is a correlation between the quality of anatomical correction and overall wrist function. However, surgical correction can be difficult because of the often complex anatomy associated with this condition. Computer assisted surgical planning, combined with patient-specific surgical guides, has the potential to improve pre-operative understanding of patient anatomy as well as intra-operative accuracy. For patients with malunion of the distal radius fracture, this technology could significantly improve clinical outcomes that largely depend on the quality of restoration of normal anatomy. Therefore, the objective of this study is to compare patient outcomes after corrective osteotomy for distal radius malunion with and without preoperative computer-assisted planning and peri-operative patient-specific surgical guides. Methods/Design This study is a multi-center randomized controlled trial of conventional planning versus computer-assisted planning for surgical correction of distal radius malunion. Adult patients with extra-articular malunion of the distal radius will be invited to enroll in our study. After providing informed consent, subjects will be randomized to two groups: one group will receive corrective surgery with conventional preoperative planning, while the other will receive corrective surgery with computer-assisted pre-operative planning and peri-operative patient specific surgical guides. In the computer-assisted planning group, a CT scan of the affected forearm as well as the normal, contralateral forearm will be obtained. The images will be used to construct a 3D anatomical model of the defect and patient-specific surgical guides will be manufactured. Outcome will be measured by DASH and PRWE scores, grip strength, radiographic measurements, and patient satisfaction at 3, 6, and 12 months

  6. Fractures of the distal phalanx in the horse

    International Nuclear Information System (INIS)

    Yovich, J.V.

    1989-01-01

    Fractures of the distal phalanx are an important cause of lameness referable to the foot. Depending on the fracture configuration and articular involvement, conservative or surgical treatment may be required. Fractures of the distal phalanx have been divided into six categories based on fracture configuration. Discussion of clinical features, management, and prognosis for horses with distal phalangeal fractures is presented for each fracture type

  7. [Unidirectional versus multidirectional palmar locking osteosynthesis of unstable distal radius fractures: comparative analysis with LDR 2.4 mm versus 2.7 mm matrix-Smartlock].

    Science.gov (United States)

    Hakimi, M; Jungbluth, P; Gehrmann, S; Nowak, J; Windolf, J; Wild, M

    2010-03-01

    Due to advances in the development of the unidirectional locking plates there is now an increased use of multidirectional palmar locking plates in the treatment of distal radius factures. The purpose of this study was to evaluate a possible improvement of the treatment and results. This prospective cohort study investigated 40 patients with C1 and C2 Colles' fractures who had been treated with unidirectional and multidirectional locking plates. The average time for the follow-up examinations was 12.3 months (range 12-15 months) after surgery. The intra-operative functional (neutral-zero method), radiological and subjective (DASH score, VAS) results were evaluated. The intra-operative fluoroscopy time of the unidirectional group was 58 s shorter compared to the multidirectional group. All fractures healed without any complication. The radiological, subjective (DASH score) and objective results for both groups were good and showed no differences. Unidirectional palmar locking plates are equally suited for the therapy of C1 and C2 fractures as multidirectional palmar locking plates but multidirectional plates require a longer fluoroscopy time.

  8. A new method for classifying distal radius fracture: the IDEAL classification Um novo método de classificação para as fraturas da extremidade distal do rádio – a classificação IDEAL

    Directory of Open Access Journals (Sweden)

    João Carlos Belloti

    2013-01-01

    Full Text Available OBJECTIVES: To describe the new IDEAL method from classifying distal radius fractures. METHODS: IDEAL classification system is based on the most important literature evidences about clinical and radiographic characteristics that influence in the treatment and prognosis for patients that suffered from a distal radius fractures. In this method, we classify the fracture in patients first consultation, in which we collect demographical (age and trauma energy and radiographic characteristics ( fracture deviation, articular fracture, and associated lesions. For each feature a score is attributed for grouping purposes. Group I - Stable fractures, good prognosis; Group II - potentially unstable fractures, commonly treated by surgical methods. Prognosis depends on surgeons' success after method choice. Group III - complex and instable fractures, poor outcome is expected. CONCLUSION: IDEAL classification staging rationale was presented, which is based on the best available evidence. The evidence of its scientific plausibility will be settled with the assessment of the classification reliability and its capacity to aid in therapeutical decisions and as a tool to predict prognosis. Further studies are under development to support these properties. OBJETIVOS: Descrição do método de Classificação IDEAL - para as fraturas da extremidade distal do rádio. MÉTODOS: O sistema de classificação IDEAL fundamenta-se nas principais evidências da literatura sobre fatores clínicos e radiográficos que influenciam o tratamento e prognóstico das fraturas do rádio distal. Classificamos as fraturas no atendimento inicial do paciente mediante a verificação de dois dados epidemiológicos e três dados radiográficos: Idade do paciente, energia do trauma, desvio dos fragmentos, incongruência articular e lesões associadas. RESULTADOS: Conforme a pontuação obtida, agrupamos os casos em três grupos: Grupo I - fraturas estáveis com bom prognóstico, Grupo II

  9. Immobilisation of extra-articular distal radius fractures (Colles type) in dorsiflexion. The functional and anatomical outcome.

    Science.gov (United States)

    Baruah, Ranjit Kr; Islam, Mohibul; Haque, Russel

    2015-09-01

    Cast immobilisation after successful closed reduction is a standard treatment for displaced extra-articular fractures of lower end radius. The position of the wrist during immobilisation is controversial. Immobilisation in dorsiflexion prevents redisplacement after closed reduction. Our aim is to determine the effectiveness of immobilization of wrist in dorsiflexion in such cases and evaluate anatomical and functional outcome. Study included 54 patients, above 19 years of age with closed extra-articular fractures of lower end radius treated conservatively with below elbow cast application. The wrist was maintained in 15° of dorsiflexion during plaster immobilisation. At 24 weeks, functional results were evaluated with subjective symptoms and objective signs, as per modified Demerit Point Score System. Anatomical result was evaluated based on the scheme devised by Lidstrom (1959) and modified by Sarmiento et al. (1980). 76% patients had Excellent to Good subjective symptoms. Out of 42 patients that had residual dorsal angulation of less than 10°, 37 had excellent to good functional outcome. 39 of the 43 patients who had loss of radial length less than 6 mm had excellent to good functional outcome. 40 out of 49 patients having loss of radial angulation less than 9° showed excellent to good functional outcome. Functional result was directly proportional to anatomical outcome. Cast immobilization of extra articular fractures of lower end radius with wrist in dorsiflexion prevents re-displacement of the fragments resulting in satisfactory anatomical & functional outcome.

  10. Synchronous Multicentric Giant Cell Tumour of Distal Radius and Sacrum with Pulmonary Metastases

    Directory of Open Access Journals (Sweden)

    Varun Sharma Tandra

    2015-01-01

    Full Text Available Giant cell tumour (GCT is an uncommon primary bone tumour, and its multicentric presentation is exceedingly rare. We report a case of a 45-year-old female who presented to us with GCT of left distal radius. On the skeletal survey, osteolytic lesion was noted in her right sacral ala. Biopsy confirmed both lesions as GCT. Pulmonary metastasis was also present. Resection-reconstruction arthroplasty for distal radius and thorough curettage and bone grafting of the sacral lesion were done. Multicentric GCT involving distal radius and sacrum with primary sacral involvement is not reported so far to our knowledge.

  11. Study on Oneself Developed to Apparatus Position of Measurement of BMD in the Distal Radius

    International Nuclear Information System (INIS)

    Han, Man Seok; Song, Jae Yong; Lee, Hyun Kuk; Yu, Se Jong; Kim, Yong Kyun

    2009-01-01

    The aim of this study was to evaluate the difference of bone mineral density according to distal radius rotation and to develop the supporting tool to measure rotation angles. CT scanning and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 20 males. Twenty healthy volunteers without any history of operations, anomalies, or trauma were enrolled. The CT scan was used to evaluate the cross sectional structure and the rotation angle on the horizontal plane of the distal radius. The rotational angle was measured by the m-view program on the PACS monitor. The DXA was used in 20 dried radii of cadaveric specimens in pronation and supination with five and ten degrees, respectively, including a neutral position (zero degrees) to evaluate the changes of BMD according to the rotation. The mean rotation angle of the distal radius on CT was 7.4 degrees of supination in 16 cases (80%), 3.3 degrees of pronation in three cases (15%), and zero degree of neutral in one case (9%), respectively. The total average rotation angle in 20 people was 5.4 degrees of supination. In the cadaveric study, the BMD of the distal radius was different according to the rotational angles. The lowest BMD was obtained at 3.3 degrees of supination. In the case of the measurement of BMD in the distal radius with a neutral position, the rotational angle of the distal radius is close to supination. Pronation is needed for the constant measurement of BMD in the distal radius with the rotation angle measuring at the lowest BMD and about five degrees of pronation of the distal radius is recommended.

  12. Effects of circumferential rigid wrist orthoses in rehabilitation of patients with radius fracture at typical site

    Directory of Open Access Journals (Sweden)

    Đurović Aleksandar

    2005-01-01

    Full Text Available Background. The use of orthoses is a questionable rehabilitation method for patients with the distal radius fracture at typical site. The aim of this study was to compare the effects of the rehabilitation on patients with radius fracture at the typical site, who wore circumferential static wrist orthoses, with those who did not wear them. Methods. Thirty patients were divided into 3 equal groups, 2 experimental groups, and 1 control group. The patients in the experimental groups were given the rehabilitation program of wearing serially manufactured (off-the-shelf, as well as custom-fit orthoses. Those in the control group did not wear wrist orthoses. Evaluation parameters were pain, edema, the range of the wrist motion, the quality of cylindrical, spherical, and pinch-spherical grasp, the strength of pinch and hand grasp, and patient's assessment of the effects of rehabilitation. Results. No significant difference in the effects of rehabilitation on the patients in experimental groups as opposed to control group was found. Patients in the first experimental group, and in control group were more satisfied with the effects of rehabilitation, as opposed to the patients in the second experimental group (p<0,05. Conclusion. The effects of circumferential static wrist orthoses in the rehabilitation of patients with distal radius fracture at the typical site were not clinically significant. There was no significant difference between the custom and off-the-shelf orthoses.

  13. Effect of low appendicular lean mass, grip strength, and gait speed on the functional outcome after surgery for distal radius fractures.

    Science.gov (United States)

    Roh, Young Hak; Noh, Jung Ho; Gong, Hyun Sik; Baek, Goo Hyun

    2017-12-01

    Patients with low appendicular lean mass plus slow gait speed or weak grip strength are at risk for poor functional recovery after surgery for distal radius fracture, even when they have similar radiologic outcomes. Loss of skeletal muscle mass and consequent loss in muscle function associate with aging, and this condition negatively impacts the activities of daily living and increases elderly individuals' frailty to falls. Thus, patients with low appendicular lean mass would show different functional recovery compared to those without this condition after surgery for distal radius fracture (DRF). This study compares the functional outcomes after surgery for DRF in patients with or without low appendicular lean mass plus slowness or weakness. A total of 157 patients older than 50 years of age with a DRF treated via volar plate fixation were enrolled in this prospective study. A definition of low appendicular lean mass with slowness or weakness was based on the consensus of the Asian Working Group for Sarcopenia. The researchers compared functional assessments (wrist range of motion and Michigan Hand Questionnaire [MHQ]) and radiographic assessments (radial inclination, volar tilt, ulnar variance, and articular congruity) 12 months after surgery between patients with and without low appendicular lean mass plus slowness or weakness. Multivariable regression analyses were performed to determine whether appendicular lean mass, grip strength, gait speed, patient demographic, or injury characteristics accounted for the functional outcomes. Patients with low appendicular lean mass plus slowness or weakness showed a significantly lower recovery of MHQ score than those in the control group throughout 12 months. There was no significant difference in the range of motion between the groups. The radiologic outcomes showed no significant difference between groups in terms of volar tilt, radial inclination, or ulnar variance. According to multivariable regression analysis

  14. Determination of bone mineral density at distal radius measured by single photon absorptiometry

    International Nuclear Information System (INIS)

    Tomomitsu, Tatsushi; Yanagimoto, Shinichi; Hitomi, Go; Murakami, Akihiko; Suemori, Shinji; Yokobayashi, Tsuneo; Ishii, Koshi; Hiji, Hiroo

    1988-01-01

    We have discussed the index of the bone mineral density (BMD) at the distal radius measured by single photon absorptiometry. Initially, the shape at the distal radius was evaluated using an X-ray photogram of the forearm and a calculation formula of the cross-sectional area at the distal radius was performed using an X-CT photogram of the forearm. A new index for the bone mineral density (modified BMD, mBMD), bone mineral content/cross-sectional area, at the distal radius was obtained for 154 young normal subjects (20 ∼ 44 yrs.). No significant differences in the mBMD values between young normal males and females, except for the group 20 ∼ 24 year-old group, were observed. Furthermore, a significantly decreased in the mBMD values with aging was observed in females between the ages of 20 ∼ 24 and 40 ∼ 44. However, no significant changes in the mBMD values were recognized in the men. Thus, it was shown that the new BMD index, mBMD, was useful for evaluating the changes of the bone mass. (author)

  15. Design and evaluation of a portable intra-operative unified-planning-and-guidance framework applied to distal radius fracture surgery.

    Science.gov (United States)

    Magaraggia, Jessica; Wei, Wei; Weiten, Markus; Kleinszig, Gerhard; Vetter, Sven; Franke, Jochen; John, Adrian; Egli, Adrian; Barth, Karl; Angelopoulou, Elli; Hornegger, Joachim

    2017-01-01

    During a standard fracture reduction and fixation procedure of the distal radius, only fluoroscopic images are available for planning of the screw placement and monitoring of the drill bit trajectory. Our prototype intra-operative framework integrates planning and drill guidance for a simplified and improved planning transfer. Guidance information is extracted using a video camera mounted onto a surgical drill. Real-time feedback of the drill bit position is provided using an augmented view of the planning X-rays. We evaluate the accuracy of the placed screws on plastic bones and on healthy and fractured forearm specimens. We also investigate the difference in accuracy between guided screw placement versus freehand. Moreover, the accuracy of the real-time position feedback of the drill bit is evaluated. A total of 166 screws were placed. On 37 plastic bones, our obtained accuracy was [Formula: see text] mm, [Formula: see text] and [Formula: see text] in tip position and orientation (azimuth and elevation), respectively. On the three healthy forearm specimens, our obtained accuracy was [Formula: see text] mm, [Formula: see text] and [Formula: see text]. On the two fractured specimens, we attained: [Formula: see text] mm, [Formula: see text] and [Formula: see text]. When screw plans were applied freehand (without our guidance system), the achieved accuracy was [Formula: see text] mm, [Formula: see text], while when they were transferred under guidance, we obtained [Formula: see text] mm, [Formula: see text]. Our results show that our framework is expected to increase the accuracy in screw positioning and to improve robustness w.r.t. freehand placement.

  16. Distal antebrachial fractures in toy-breed dogs

    International Nuclear Information System (INIS)

    Muir, P.

    1997-01-01

    Antebrachial fractures account for approximately 17% of all canine fractures, with motor vehicle trauma cited as one of the primary causes. However, antebrachial fractures in toy-breed dogs are often sustained after apparently minimal trauma, such as jumping or falling, and are usually distal. The cause of antebrachial fractures in toy breeds is not well understood. Complications after treatment of distal antebrachial fractures in toy-breed dogs, including delayed union, nonunion, and malunion, are common and are potentially serious because they may necessitate limb amputation. This article reports on distal antebrachial fractures in 26 toy-breed dogs that wee presented to the University of California, Davis, Veterinary Medical Teaching Hospital from April 1987 to March 1996. The author found that (1) these fractures typically occur in growing or adolescent dogs; (2) the presence of complications of union is typically associated with prior treatment using intramedullary pinning or external coaptation; and (3) successful healing of this type of fracture is obtained via rigid stabilization with bone plating in combination with cancellous bone autograft

  17. Distal clavicular osteolysis: MR evidence for subchondral fracture

    Energy Technology Data Exchange (ETDEWEB)

    Kassarjian, Ara; Palmer, William E. [Massachusetts General Hospital, Department of Radiology, Division of Musculoskeletal Radiology, Yawkey Center, Boston, MA (United States); Llopis, Eva [Hospital de la Ribera, Department of Radiology, Valencia (Spain)

    2007-01-15

    To investigate the association between distal clavicular osteolysis and subchondral fractures of the distal clavicle at MRI. This study was approved by the hospital human research committee, which waived the need for informed consent. Three radiologists retrospectively analyzed 36 shoulder MR examinations in 36 patients with imaging findings of distal clavicular osteolysis. The presence of a subchondral fracture of the distal clavicle, abnormalities of the acromioclavicular joint, rotator cuff tears and labral tears were assessed by MRI. These cases were then compared with 36 age-matched controls. At MRI, 31 of 36 patients (86%) had a subchondral line within the distal clavicular edema, consistent with a subchondral fracture. Of the 36 patients, 32 (89%) had fluid in the acromioclavicular joint, while 27 of 36 patients (75%) had cysts or erosions in the distal clavicle. There were 13 patients (36%) with associated labral tears, while eight patients (22%) had partial-thickness rotator cuff tears. In the control group one of 36 (3%) had a subchondral line (P<0.05), while ten of 36 (28%) had rotator cuff tears and 13 of 36 (36%) had labral tears. These latter two were not statistically significant between the groups. A distal clavicular subchondral fracture is a common finding in patients with imaging evidence of distal clavicular osteolysis. These subchondral fractures may be responsible for the propensity of findings occurring on the clavicular side of the acromioclavicular joint. (orig.)

  18. Distal clavicular osteolysis: MR evidence for subchondral fracture

    International Nuclear Information System (INIS)

    Kassarjian, Ara; Palmer, William E.; Llopis, Eva

    2007-01-01

    To investigate the association between distal clavicular osteolysis and subchondral fractures of the distal clavicle at MRI. This study was approved by the hospital human research committee, which waived the need for informed consent. Three radiologists retrospectively analyzed 36 shoulder MR examinations in 36 patients with imaging findings of distal clavicular osteolysis. The presence of a subchondral fracture of the distal clavicle, abnormalities of the acromioclavicular joint, rotator cuff tears and labral tears were assessed by MRI. These cases were then compared with 36 age-matched controls. At MRI, 31 of 36 patients (86%) had a subchondral line within the distal clavicular edema, consistent with a subchondral fracture. Of the 36 patients, 32 (89%) had fluid in the acromioclavicular joint, while 27 of 36 patients (75%) had cysts or erosions in the distal clavicle. There were 13 patients (36%) with associated labral tears, while eight patients (22%) had partial-thickness rotator cuff tears. In the control group one of 36 (3%) had a subchondral line (P<0.05), while ten of 36 (28%) had rotator cuff tears and 13 of 36 (36%) had labral tears. These latter two were not statistically significant between the groups. A distal clavicular subchondral fracture is a common finding in patients with imaging evidence of distal clavicular osteolysis. These subchondral fractures may be responsible for the propensity of findings occurring on the clavicular side of the acromioclavicular joint. (orig.)

  19. [New anterolateral approach of distal femur for treatment of distal femoral fractures].

    Science.gov (United States)

    Zhang, Bin; Dai, Min; Zou, Fan; Luo, Song; Li, Binhua; Qiu, Ping; Nie, Tao

    2013-11-01

    To assess the effectiveness of the new anterolateral approach of the distal femur for the treatment of distal femoral fractures. Between July 2007 and December 2009, 58 patients with distal femoral fractures were treated by new anterolateral approach of the distal femur in 28 patients (new approach group) and by conventional approach in 30 patients (conventional approach group). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, disease duration, complication, or preoperative intervention (P > 0.05). The operation time, intraoperative blood loss, intraoperative fluoroscopy frequency, hospitalization days, and Hospital for Special Surgery (HSS) score of knee were recorded. Operation was successfully completed in all patients of 2 groups, and healing of incision by first intention was obtained; no vascular and nerves injuries occurred. The operation time and intraoperative fluoroscopy frequency of new approach group were significantly less than those of conventional approach group (P 0.05). All patients were followed up 12-36 months (mean, 19.8 months). Bone union was shown on X-ray films; the fracture healing time was (12.62 +/- 2.34) weeks in the new approach group and was (13.78 +/- 1.94) weeks in the conventional approach group, showing no significant difference (t=2.78, P=0.10). The knee HSS score at last follow-up was 94.4 +/- 4.2 in the new approach group, and was 89.2 +/- 6.0 in the conventional approach group, showing significant difference between 2 groups (t=3.85, P=0.00). New anterolateral approach of the distal femur for distal femoral fractures has the advantages of exposure plenitude, minimal tissue trauma, and early function rehabilitation training so as to enhance the function recovery of knee joint.

  20. A trans-ethnic genome-wide association study identifies gender-specific loci influencing pediatric aBMD and BMC at the distal radius.

    Science.gov (United States)

    Chesi, Alessandra; Mitchell, Jonathan A; Kalkwarf, Heidi J; Bradfield, Jonathan P; Lappe, Joan M; McCormack, Shana E; Gilsanz, Vicente; Oberfield, Sharon E; Hakonarson, Hakon; Shepherd, John A; Kelly, Andrea; Zemel, Babette S; Grant, Struan F A

    2015-09-01

    Childhood fractures are common, with the forearm being the most common site. Genome-wide association studies (GWAS) have identified more than 60 loci associated with bone mineral density (BMD) in adults but less is known about genetic influences specific to bone in childhood. To identify novel genetic factors that influence pediatric bone strength at a common site for childhood fractures, we performed a sex-stratified trans-ethnic genome-wide association study of areal BMD (aBMD) and bone mineral content (BMC) Z-scores measured by dual energy X-ray absorptiometry at the one-third distal radius, in a cohort of 1399 children without clinical abnormalities in bone health. We tested signals with P BMC-Z). Signals at the CPED1-WNT16-FAM3C locus have been previously associated with BMD at other skeletal sites in adults and children. Our result at the distal radius underscores the importance of this locus at multiple skeletal sites. The 9p21.3 locus is within a gene desert, with the nearest gene flanking each side being MIR31HG and MTAP, neither of which has been implicated in BMD or BMC previously. These findings suggest that genetic determinants of childhood bone accretion at the radius, a skeletal site that is primarily cortical bone, exist and also differ by sex. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. External fixation is more suitable for intra-articular fractures of the distal radius in elderly patients

    Science.gov (United States)

    Ma, Chuang; Deng, Qiang; Pu, Hongwei; Cheng, Xinchun; Kan, Yuhua; Yang, Jing; Yusufu, Aihemaitijiang; Cao, Li

    2016-01-01

    The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after 1 week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P=0.001), supination, (P=0.047) and extension (P=0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at 1 year. The plating group had a greater occurrence of wound infection (P=0.043), tendonitis, (P=0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the “gross motor” category (walking upstairs, bending over, walking 500 yards; P=0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after 1 year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries. PMID:27408765

  2. Epidemiology of distal forearm fractures in Oslo, Norway.

    Science.gov (United States)

    Lofthus, C M; Frihagen, F; Meyer, H E; Nordsletten, L; Melhuus, K; Falch, J A

    2008-06-01

    The population of Oslo has the highest incidence of hip fracture reported. The present study shows that the overall incidence of distal forearm fractures in Oslo is higher than in other countries and has not changed significantly when comparing the incidence of 1998/99 with 1979. The population of Oslo has the highest incidence of hip fracture reported. The present study reports the incidence of distal forearm fracture in Oslo and the fracture rates of immigrants. Patients aged > or = 20 years resident in Oslo sustaining a distal forearm fracture in a one-year period in 1998/99 were identified using electronic diagnosis registers, patient protocols, and/or X-ray registers of the clinics in Oslo. Medical records were obtained and the diagnosis verified. The age- and sex-specific incidence rates were calculated and compared with those for 1979. Data on immigrant category and country of origin of the patients were obtained. The age-adjusted fracture rates per 10,000 for the age group > or = 50 years were 109.8 and 25.4 in 1998/99 compared with 108.3 and 23.5 in 1979 for women and men, respectively (n.s.). The relative risk of fracture in Asians was 0.72 (95% CI 0.53-1.00) compared with ethnic Norwegians. The overall incidence of distal forearm fractures in Oslo is higher than in other countries and has not changed significantly when comparing the incidence of 1998/99 with 1979. Furthermore, the present data suggest that Asian immigrants in Oslo have a slightly lower fracture risk than ethnic Norwegians.

  3. A FUNCTIONAL EVALUATION STUDY OF DISTAL FEMORAL FRACTURES FIXED WITH DISTAL FEMORAL LOCKING PLATE

    Directory of Open Access Journals (Sweden)

    Manikumar C. J

    2017-04-01

    Full Text Available BACKGROUND Fractures of the distal femur present considerable challenges in management. Older patients especially women sustain fractures due to osteoporosis. Supracondylar fractures of femur have a bimodal distribution. They account for 6% of all femur fractures and 31% if hip fractures were excluded. Nearly, 50% of distal femur intra-articular fractures are open fractures. Before 1970, most supracondylar fractures were treated nonoperatively; however, difficulties were often encountered including persistent angulatory deformity, knee joint incongruity, loss of knee motion and delayed mobilisation. The trend of open reduction and internal fixation has become evident in recent years with good results being obtained with AO blade plate, dynamic condylar screw, intramedullary supracondylar nail and locking compression plate. Elderly patients and osteoporosis pose difficulty in treating intra-articular fractures of the lower end of femur. Loss of stable fixation is of great concern in these cases. Hence, locking compression plate use has an advantage in these patients. MATERIALS AND METHODS In this study, 20 patients with closed fracture of distal femur were studied. All the cases were treated at the Department of Orthopaedics, Rangaraya Medical College/Government General Hospital, Kakinada, Andhra Pradesh, between November 2013 and November 2015. The method used for fracture fixation was open reduction and internal fixation with distal femoral locking plate. The duration of follow up ranged from 3 months to 24 months. All the fractures in this series were posttraumatic. The patients were functionally evaluated with Neer’s scoring system. 1 RESULTS Twenty distal femoral fractures were treated with distal femoral locking plates. 15 patients were males and 5 patients were females. The median age was 47 years ranging from 28-70 years. 16 of the fractures were caused by road traffic accidents and 2 were due to fall, 2 were due to assault. 12 patients

  4. Study protocol: non-displaced distal radial fractures in adult patients: three weeks vs. five weeks of cast immobilization: a randomized trial

    NARCIS (Netherlands)

    Bentohami, Abdelali; de Korte, Niels; Sosef, Nico; Goslings, Johan Carel; Bijlsma, Taco; Schep, Niels

    2014-01-01

    Up to 30% of patients suffer from long-term functional restrictions following conservative treatment of distal radius fractures. Whether duration of cast immobilisation influences functional outcome remains unclear. The aim of the study is to evaluate whether the duration of immobilization of non or

  5. Impact of double-tiered subchondral support procedure with a polyaxial locking plate on the stability of distal radius fractures using fresh cadaveric forearms: Biomechanical and radiographic analyses.

    Science.gov (United States)

    Tsutsui, Sadaaki; Kawasaki, Keikichi; Yamakoshi, Ken-Ichi; Uchiyama, Eiichi; Aoki, Mitsuhiro; Inagaki, Katsunori

    2016-09-01

    The present study compared the changes in biomechanical and radiographic properties under cyclic axial loadings between the 'double-tiered subchondral support' (DSS) group (wherein two rows of screws were used) and the 'non-DSS' (NDSS) group (wherein only one row of distal screws was used) using cadaveric forearm models of radius fractures fixed with a polyaxial locking plate. Fifteen fresh cadaveric forearms were surgically operated to generate an Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 23-C2 fracture model with the fixation of polyaxial volar locking plates. The model specimens were randomized into two groups: DSS (n = 7) and NDSS (n = 8). Both the groups received 4 locking screws in the most distal row, as is usually applied, whereas the DSS group received 2 additional screws in the second row inserted at an inclination of about 15° to support the dorsal aspect of the dorsal subchondral bone. Cyclic axial compression test was performed (3000 cycles; 0-250 N; 60 mm/min) to measure absolute rigidity and displacement, after 1, 1000, 2000 and 3000 cycles, and values were normalized relative to cycle 1. These absolute and normalized values were compared between those two groups. Radiographic images were taken before and after the cyclic loading to measure changes in volar tilt (ΔVT) and radial inclination (ΔRI). The DSS group maintained significantly higher rigidity and lower displacement values than the NDSS group during the entire loading period. Radiographic analysis indicated that the ΔVT values of the DSS group were lower than those of the NDSS group. In contrast, the fixation design did not influence the impact of loading on the ΔRI values. Biomechanical and radiographic analyses demonstrated that two rows of distal locking screws in the DSS procedure conferred higher stability than one row of distal locking screws. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  6. Testing the validity of preventing chronic regional pain syndrome with vitamin C after distal radius fracture. [Corrected].

    Science.gov (United States)

    Malay, Sunitha; Chung, Kevin C

    2014-11-01

    The American Academy of Orthopaedic Surgeons recommends the use of vitamin C to prevent complex regional pain syndrome (CRPS) for patients with distal radius fractures (DRFs). We hypothesized that the evidence for supporting this recommendation is weak, based on epidemiological principles of association and causality. The specific aim of this project was to test the validity of this recommendation. We conducted a literature review to retrieve articles reporting on the use of vitamin C to prevent CRPS. Data collected included sample size, study design type, dose of vitamin C used, and outcome measures of association expressed as relative risk (RR) and odds ratio. We then applied Hill criteria to evaluate the relationship between vitamin C and CRPS. We obtained 225 articles from the database search. After the exclusion of duplicates, unrelated articles, editorial letters, and commentaries, we found 4 articles and 1 systematic review relevant to our topic. Six of the 9 Hill criteria were met, and an earlier meta-analysis showed a quantified reduction in CRPS risk. However, criteria like biological plausibility, specificity, and coherence were not met. The number of causal/association criteria met was adequate to support the scientific premise of the effect of vitamin C in preventing CRPS after DRF. Furthermore, vitamin C administration is of relatively low cost and has few complications unless administered in large doses. Owing to sufficient epidemiological evidence availability, the American Academy of Orthopaedic Surgeons recommendation of vitamin C to prevent CRPS has practical merit. Therapeutic II. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  7. Fishtail deformity - a delayed complication of distal humeral fractures in children

    Energy Technology Data Exchange (ETDEWEB)

    Narayanan, Srikala [Massachusetts General Hospital, Department of Radiology, Division of Pediatric Imaging, Boston, MA (United States); University of Pittsburgh Medical Center, Department of Radiology, Pittsburgh, PA (United States); Shailam, Randheer; Nimkin, Katherine [Massachusetts General Hospital, Department of Radiology, Division of Pediatric Imaging, Boston, MA (United States); Grottkau, Brian E. [Massachusetts General Hospital, Department of Orthopaedics, Pediatric Orthopaedics, Boston, MA (United States)

    2015-06-15

    Concavity in the central portion of the distal humerus is referred to as fishtail deformity. This entity is a rare complication of distal humeral fractures in children. The purpose of this study is to describe imaging features of post-traumatic fishtail deformity and discuss the pathophysiology. We conducted a retrospective analysis of seven cases of fishtail deformity after distal humeral fractures. Seven children ages 7-14 years (five boys, two girls) presented with elbow pain and history of distal humeral fracture. Four of the seven children had limited range of motion. Five children had prior grade 3 supracondylar fracture treated with closed reduction and percutaneous pinning. One child had a medial condylar fracture and another had a lateral condylar fracture; both had been treated with conservative casting. All children had radiographs, five had CT and three had MRI. All children had a concave central defect in the distal humerus. Other imaging features included joint space narrowing with osteophytes and subchondral cystic changes in four children, synovitis in one, hypertrophy or subluxation of the radial head in three and proximal migration of the ulna in two. Fishtail deformity of the distal humerus is a rare complication of distal humeral fractures in children. This entity is infrequently reported in the radiology literature. Awareness of the classic imaging features can result in earlier diagnosis and appropriate treatment. (orig.)

  8. Fishtail deformity - a delayed complication of distal humeral fractures in children

    International Nuclear Information System (INIS)

    Narayanan, Srikala; Shailam, Randheer; Nimkin, Katherine; Grottkau, Brian E.

    2015-01-01

    Concavity in the central portion of the distal humerus is referred to as fishtail deformity. This entity is a rare complication of distal humeral fractures in children. The purpose of this study is to describe imaging features of post-traumatic fishtail deformity and discuss the pathophysiology. We conducted a retrospective analysis of seven cases of fishtail deformity after distal humeral fractures. Seven children ages 7-14 years (five boys, two girls) presented with elbow pain and history of distal humeral fracture. Four of the seven children had limited range of motion. Five children had prior grade 3 supracondylar fracture treated with closed reduction and percutaneous pinning. One child had a medial condylar fracture and another had a lateral condylar fracture; both had been treated with conservative casting. All children had radiographs, five had CT and three had MRI. All children had a concave central defect in the distal humerus. Other imaging features included joint space narrowing with osteophytes and subchondral cystic changes in four children, synovitis in one, hypertrophy or subluxation of the radial head in three and proximal migration of the ulna in two. Fishtail deformity of the distal humerus is a rare complication of distal humeral fractures in children. This entity is infrequently reported in the radiology literature. Awareness of the classic imaging features can result in earlier diagnosis and appropriate treatment. (orig.)

  9. Valgusdeformitet i anklen som følge af distal fibula-epifysefraktur

    DEFF Research Database (Denmark)

    Al-Aubaidi, Zaid

    2011-01-01

    Ankle fracture with involvement of the growth plate is the second most common paediatric fracture after the distal radius. The most common fracture type according to Salter Harris (SH) is type II of the distal tibia combined with green stick of the fibula. Isolated fracture of the distal fibular...... growth plate is not common and as a rule it does not give any growth arrest. We describe a case of isolated fibular fracture SH type II in a ten year-old girl which ended with symptomatic valgus deformity of the ankle. The patient was operated with good results....

  10. Minimally invasive percutaneous plate fixation of distal tibia fractures.

    LENUS (Irish Health Repository)

    Bahari, Syah

    2007-10-01

    We report a series of 42 patients reviewed at a mean of 19.6 months after treatment of distal tibial and pilon fractures using the AO distal tibia locking plate with a minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. Mean time to union was 22.4 weeks. All fractures united with acceptable alignment and angulation. Two cases of superficial infection were noted, with one case of deep infection. Mean SF36 score was 85 and mean AOFAS score was 90 at a mean of 19 months follow-up. We report satisfactory outcomes with the use of the AO distal tibia locking plate in treatment of unstable distal tibial fractures. Eighty-nine percent of the patients felt that they were back to their pre injury status and 95% back to their previous employment.

  11. Occupational therapy and Colles' fractures.

    Science.gov (United States)

    Christensen, O M; Kunov, A; Hansen, F F; Christiansen, T C; Krasheninnikoff, M

    2001-01-01

    In this randomized trial, we enrolled 30 patients treated for a distal radius Colles' type fracture. The fractures were reduced if necessary and fixed in a below-elbow plaster cast for 5 weeks. One group consisting of 14 patients received instructions for shoulder; elbow and finger exercise and the other group consisting of 16 patients had occupational therapy. At 5 weeks, 3 and 9 months we measured the functional scores. There were no statistically significant differences between the groups at any time. It seems that for non-surgically treated patients with a distal radius fracture only instructions are necessary.

  12. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients

    OpenAIRE

    Gupta, Rakesh K.; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2009-01-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-...

  13. Locking plates in distal humerus fractures: study of 43 patients

    Directory of Open Access Journals (Sweden)

    Gupta Rakesh Kumar

    2013-08-01

    Full Text Available 【Abstract】Objective: The treatment of multi-fragmentary, intraarticular fractures of the distal humerus is difficult, even in young patients with bone of good quality. Small distal fragment, diminished bone mineral quality and increased trauma-associated joint destruction make stable joint reconstruction more problematic. The anatomically preshaped locking plates allow angular stable fixation for these complex fractures. We evaluated functional results of patients treated with open reduction and internal fixation with distal humerus locking plates for complex distal hu-merus fractures. Methods: Forty-three consecutive patients with ar-ticular fractures of the distal humerus were treated by open reduction and internal fixation with AO distal humerus plate system and locking reconstruction plates. Forty patients were available for the final outcome analysis. According to AO/ASIF classification, there were 2 cases of type A2, 4 cases of type A3, 1 case of type B1, 1 case of type B2, 14 cases of type C1, 7 cases of type C2 and 11 cases of type C3. Open reduction with triceps splitting technique was used in all patients. The clinical and radiographic follow-up was performed and outcome measures included pain assessment, range of motion, and Mayo elbow performance score. Results: Forty patients were available for the final outcome analysis. There were 29 males and 11 females with an average age of 38.4 years (18-73 years. Clinical and ra-diological consolidation of the fracture was observed in all cases at an average of 11.6 weeks (9-14 weeks. The average follow-up was 12 months (10-18 months. Using the Mayo elbow performance score the results obtained were graded as excellent or good results in 33 patients (82.5%. One pa-tient had superficial infection, and 4 had myositis ossificans. There were no cases of primary malposition or secondary displacement, implant failure or ulnar neuropathy. Conclusion: Anatomically preshaped distal humerus locking

  14. Open segmental fracture of both bone forearm and dislocation of ipsilateral elbow with extruded middle segment radius

    Directory of Open Access Journals (Sweden)

    Pawan Kumar

    2013-01-01

    Full Text Available Extruded middle segment of radius with open segmental fracture both bone forearm and dislocation of ipsilateral elbow is a rare injury. A 12-year-old child presented to us within 4 hours following fall from tree. The child′s mother was carrying a 12-cm-long extruded soiled segment of radius. The extruded bone was thoroughly washed. The medullary cavity was properly syringed with antiseptic solution. The bone was autoclaved and put in the muscle plane of the distal forearm after debridement of the wound. After 5 days, a 2.5-mm K-wire was introduced by retrograde method into the proximal radius by passing through the extruded segment. Another 2.5-mm K-wire was passed in ulna. The limb was evaluated clinicoradiologically every 2 weeks. The wound was healed by primary intention. At 4 months, the reposed bone appeared less dense radiologically and K-wire seemed to be out of the bone. In the subsequent months, the roentgenograms show remodeling of the extruded fragment. After 20 weeks, the K-wires were removed (first ulnar and then radial. Complete union was achieved with full range of movement except loss of few degrees of extension of elbow and thumb. This case is reported to show a good outcome following successful incorporation of an extruded segment of radius in an open fracture.

  15. A PROSPECTIVE STUDY OF DISTAL TIBIAL FRACTURES BY MIPO (LCP

    Directory of Open Access Journals (Sweden)

    Chandra Sekharam Naidu

    2015-05-01

    Full Text Available INTRODUCTION: D istal tibial fractures represent a significant challenge to most of the surgeons even today. They constitute 1 - 10% of all lower extremity fractures . 1 The difficulty in treating the fractures of distal tibial end is exemplif ied by orthopedists, who in the first half of twentieth century, believed these injuries were so severe and fraught with so many complications, that these fractures were deemed not amenable for surgical reconstruction . 2 Conservative treatment by POP cast l ead to prolonged immobilization, leading to ankle and knee stiffness affecting quality of life of the patient . 3 Operative treatment is indicated for most tibial fractures caused by high energy trauma. Operative treatment allows early motion, and avoids sho rtening and other complications associated with prolonged immobilization . 4 The fundamental goal of treatment of distal tibial fractures is restoration of normal or near normal alignment and articular congruity and finally to obtain a well healed fracture; pain free weight bearing ; and functional ROM of ankle joint. For the past decade, plating has been successful in treating complex fractures of the lower extremity especially distal tibia . 5 Conventional ORIF have been associated with complications like infe ction and delayed or non - union due to devitalisation of bony fragments and additional damage to the soft tissues . 6 To improve fracture healing, more “biological” methods have been developed in the last decade to lessen the surgical dissection, preserving b lood supply to bony fragments and containing at least partially the fracture haematoma . 7 Recently, the trend is towards use of a Locking compression plate for treatment of fractures of the distal part of the tibia 8 . Compared with a conventional plate, a Lo cking compression plate imparts a higher degree of stability and provides better protection against primary and secondary losses of reduction and minimization of bone

  16. A STUDY OF SURGICAL MANAGEMENT OF DISTAL FEMORAL FRACTURES BY DISTAL FEMORAL LOCKING COMPRESSION PLATE OSTEOSYNTHESIS

    Directory of Open Access Journals (Sweden)

    Dema Rajaiah

    2016-08-01

    Full Text Available AIMS AND OBJECTIVES To study the fractures of distal end of femur and the mechanism of injury in distal end femur fractures, the advantages and disadvantages of open reduction and internal fixation of distal end femur fractures by distal femoral locking compression plate osteosynthesis and to analyse the outcome in terms of range of Knee motion, time to union, and limb shortening. RESULTS The mean age of patient is 44 years, 85% are males, road traffic accidents account for majority (80%, right side involved in 70%, Muller’s type C fracture is common, good range of movements is seen 90% of cases and union occurred in 95% in 5 months. The results were assessed using Neer’s score, seven (35% patients had excellent results, eight (40% patients had good results, four (20% patients had fair results and one (5% patient had poor result. CONCLUSION From our study, we conclude that DF-LCP is a safe and reliable implant and has shown excellent to satisfactory results in majority of intra-articular fractures (AO type C. Fixation with locking compression plate showed more effectiveness in severely osteoporotic bones, shorter operative stay, faster recovery, faster union rates and excellent functional outcome.

  17. Foal Fractures: Osteochondral Fragmentation, Proximal Sesamoid Bone Fractures/Sesamoiditis, and Distal Phalanx Fractures.

    Science.gov (United States)

    Reesink, Heidi L

    2017-08-01

    Foals are susceptible to many of the same types of fractures as adult horses, often secondary to external sources of trauma. In addition, some types of fractures are specific to foals and occur routinely in horses under 1 year of age. These foal-specific fractures may be due to the unique musculoskeletal properties of the developing animal and may present with distinct clinical signs. Treatment plans and prognoses are tailored specifically to young animals. Common fractures not affecting the long bones in foals are discussed in this article, including osteochondral fragmentation, proximal sesamoid bone fractures/sesamoiditis, and distal phalanx fractures. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Equine ulnar fracture repair with locking compression plates can be associated with inadvertent penetration of the lateral cortex of the radius.

    Science.gov (United States)

    Kuemmerle, Jan M; Kühn, Karolin; Bryner, Marco; Fürst, Anton E

    2013-10-01

    To evaluate if the use of locking head screws (LHS) in the distal holes of a locking compression plate (LCP) applied to the caudal aspect of the ulna to treat equine ulnar fractures is associated with a risk of injury to the lateral cortex of the radius. Controlled laboratory study. Cadaveric equine forelimbs (n = 8 pair). After transverse ulnar osteotomy, osteosynthesis was performed with a narrow 10-13 hole 4.5/5.0 LCP applied to the caudal aspect of each ulna. The distal 3 holes were filled with 4.5 mm cortex screws (CS) in 1 limb (group 1) and with 5.0 mm LHS contralaterally (group 2). CS were inserted in an angle deemed appropriate by the surgeon and LHS were inserted perpendicular to the plate. Implant position and injury to the lateral cortex of the radius were assessed by radiography, CT, and limb dissection. In group 1, injury of the lateral radius cortex did not occur. In group 2, 4 limbs and 6/24 LHS were associated with injury of the lateral radius cortex by penetration of a LHS. This difference was statistically significant. CS were inserted with a mean angle of 17.6° from the sagittal plane in a caudolateral-craniomedial direction. Use of LHS in the distal part of a LCP applied to the caudal aspect of the ulna is associated with a risk of inadvertent injury to the lateral cortex of the radius. © Copyright 2013 by The American College of Veterinary Surgeons.

  19. Alignment After Intramedullary Nailing of Distal Tibia Fractures Without Fibula Fixation.

    Science.gov (United States)

    De Giacomo, Anthony F; Tornetta, Paul

    2016-10-01

    To evaluate the efficacy of intramedullary nailing of distal tibia fractures using modern techniques, without fibula fixation, in obtaining and maintaining alignment. Retrospective case review. Level-I academic trauma center. One hundred thirty-two consecutive patients with distal tibia fractures. Intramedullary nail of distal tibia fracture, without fibula fixation, was performed in consecutive patients using modern reduction techniques. Malalignment and malunion were defined as >5 degrees of varus/valgus angulation or anterior/posterior angulation on the initial postoperative or final anteroposterior and lateral x-rays. There were 122 consecutive patients (86 men and 36 women) 16-93 years of age (average, 43 years) with 36 (30%) open and 85 (70%) closed fractures with complete follow-up. Mechanism of injury did not predict the presence or level of fibula fracture. Upon presentation, varus/valgus and procurvatum/recurvatum angulation was greatest when the fibula was fractured at the level of the tibia fracture (P = 0.001 and 0.028). The most common intraoperative reduction aids were nailing in relative extension, transfixion external fixation, and clamps at the fracture site. The OTA fracture type or level/presence of fibula fracture did not influence malalignment (P = 0.86 and 0.66), malunion (P = 0.81 and 0.79), or the change in alignment during union, which averaged 0.9 degrees. We found an overall low rate of both malalignment (2%) and malunion (3%) after intramedullary nailing of distal tibial shaft fracture without fibula fixation. We conclude that when modern nailing techniques are used, which allow for confirmation of reduction by visualization in fluoroscopy, from nail placement to distal interlocking, fibula fixation is not necessary to obtain or maintain alignment. Furthermore, standard 2 medial to lateral screws distally afford adequate stability to hold the reduction during union with a 0.9-degree difference in the initial postoperative and final

  20. Fractures of the distal tibia treated with polyaxial locking plating.

    Science.gov (United States)

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2009-03-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial infections and evidence of delayed wound healing. Using the American Orthopaedic Foot and Ankle Society ankle score, the average functional score was 87.3 points (of 100 total possible points). Our results show the polyaxial locking plates, which offer more fixation versatility, may be a reasonable treatment option for distal tibia fractures with very short metaphyseal segments.

  1. Rehabilitation for distal radial fractures in adults.

    Science.gov (United States)

    Handoll, Helen H G; Elliott, Joanne

    2015-09-25

    Fracture of the distal radius is a common clinical problem, particularly in older people with osteoporosis. There is considerable variation in the management, including rehabilitation, of these fractures. This is an update of a Cochrane review first published in 2002 and last updated in 2006. To examine the effects of rehabilitation interventions in adults with conservatively or surgically treated distal radial fractures. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL 2014; Issue 12), MEDLINE, EMBASE, CINAHL, AMED, PEDro, OTseeker and other databases, trial registers, conference proceedings and reference lists of articles. We did not apply any language restrictions. The date of the last search was 12 January 2015. Randomised controlled trials (RCTs) or quasi-RCTs evaluating rehabilitation as part of the management of fractures of the distal radius sustained by adults. Rehabilitation interventions such as active and passive mobilisation exercises, and training for activities of daily living, could be used on their own or in combination, and be applied in various ways by various clinicians. The review authors independently screened and selected trials, and reviewed eligible trials. We contacted study authors for additional information. We did not pool data. We included 26 trials, involving 1269 mainly female and older patients. With few exceptions, these studies did not include people with serious fracture or treatment-related complications, or older people with comorbidities and poor overall function that would have precluded trial participation or required more intensive treatment. Only four of the 23 comparisons covered by these 26 trials were evaluated by more than one trial. Participants of 15 trials were initially treated conservatively, involving plaster cast immobilisation. Initial treatment was surgery (external fixation or internal fixation) for all participants

  2. Avaliação da força de preensão e funcionalidade após fratura distal de rádio/Evaluation of strength and functionality after distal radius fracture

    Directory of Open Access Journals (Sweden)

    Bruno Goto Kimura

    2017-09-01

    Full Text Available Esse estudo teve objetivo avaliar se existe diferença em relação a força de preensão e funcionalidade de pacientes com fratura distal de rádio em relação ao gênero e ao tipo de tratamento (conservador e cirúrgico. Os pacientes recrutados para este estudo foram divididos em dois grupos, grupo de homens (G1 e grupo de mulheres (G2. Todos os voluntários realizaram uma única avaliação da força de preensão palmar e a avaliação funcional pelos questionários Disability of the Arm, Shoulder and Hand (DASH e Patient Rated Wrist Evaluation (PRWE.Os valores de força de preensão foram significativamente (p<0,000 menores no grupo de mulheres 5,42 (±3,42 e no tratamento conservador 5,20 (±4,91 quando comparados aos homens 16,01 (±6,86 e ao tratamento cirúrgico 12,28 (±7,56. Enquanto que os valores de incapacidade, avaliados pelos questionários DASH e PRWE, foram maiores no grupo de mulheres e pacientes que realizaram tratamento conservador, porém não foram encontradas diferenças significativas. As fraturas distais de rádio se não reabilitadas precocemente podem comprometer a amplitude de movimento, a força muscular, a precisão, a destreza e controle dos movimentos. Neste caso, os questionários de funcionalidade são um parâmetro importante que refletem o desempenho do indivíduo durante a realização de atividades de vida diária, sendo que quanto pior os escores, pior o desempenho e autonomia desses pacientes. Nesse estudo, podemos concluir que o gênero e o tipo de tratamento influenciaram na diminuição da força de preensão e na maior incapacidade funcional na avaliação inicial após 45 dias da fratura. AbstractThis study had the objective of evaluating whether there is a difference in the grip strength and functionality of patients with distal radius fracture in relation to gender and type of treatment (conservative and surgical. The patients recruited for this study were divided into two groups, group of men (G1

  3. Fractures of the Distal Tibia Treated with Polyaxial Locking Plating

    OpenAIRE

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2008-01-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial in...

  4. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients.

    Science.gov (United States)

    Gupta, Rakesh K; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2010-12-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures (n = 41) to maintain the second column of the ankle so as to achieve indirect reduction and to prevent collapse of the fracture. There were two cases of delayed wound breakdown in fractures fixed with the 4.5-mm LC-LCP. Five patients required primary bone grafting and three patients required secondary bone grafting. All cases of delayed union (n = 7) and nonunion (n = 3) were observed in cases where plates were used in bridge mode. Minimally invasive plate osteosynthesis (MIPO) with LCP was observed to be a reliable method of stabilisation for these fractures. Peri-operative docking of fracture ends may be a good option in severely impacted fractures with gap. The precontoured distal medial tibial LCP was observed to be a better tolerated implant in comparison to the 4.5-mm LC-LCP or metaphyseal LCP with respect to complications of soft tissues, bone healing and functional outcome, though its contour needs to be modified.

  5. Fernandez osteotomy of radio distal with mal united fracture

    International Nuclear Information System (INIS)

    Garcia Herrera, Alvaro; Bocanegra, Sergio; Suarez, Fabio

    2003-01-01

    We review prospectively our experience in the military hospital in Bogota, Colombia, with the opening-wedge osteotomy for the treatment of a mal united fracture of the distal end of the radius in fifty-six consecutive patients from 1990 to 2002. The indications for operation were pain predominantly in the radio-ulnar joint and functional limitation with grip strength loss. Preoperative radiographs revealed an average ulnar inclination of 14 degrees, an average ulnar variance of four millimeters, and increased dorsal tilt (colles deformity) that averaged 28 degrees. All patients had limited function. The average grip strength was a force of fifteen kilograms compared with a force of thirty-one kilograms in the contralateral hand. Postoperatively, all of the patients had substantial improvement in function, relief of pain and grip strength increased. The functional results were rated as very good in eleven patients, good in thirty-six, fair in nine

  6. MINIMUM INCISION PERCUTANEOUS PLATE OSTEOSYNTHESIS FOR DISTAL FIBULAR FRACTURES: A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Ramkumar Reddy

    2015-09-01

    Full Text Available Distal fibular fractures are usually communitted and most of the times osteoporotic especially if they are occurring in females and in geriatric age group. These fractures are usu ally associated with other fractures, which necessitates them to be fixed accurately. Owing to the fact that distal fragment is subcutaneous with scanty soft tissue over bone, which pose these fracture fixations become difficult by open methods in view of wound healing. A prospective study of 26 patients with distal fibular fractures were treated with MIPPO with hook plate were healed with less complications and better outcome. With this background we suggest a minimally invasive incision over proximal frag ment where sufficient soft tissue cover is present. From there pushing the special hook plate subperiosteally to distal fragment, hooking the tip of fibula and fixing the proximal fragment after reduction gives a simple and effective stable fixation

  7. Minimally Invasive Surgical Approach to Distal Fibula Fractures: A Technique Tip

    Directory of Open Access Journals (Sweden)

    Tyler A. Gonzalez

    2017-01-01

    Full Text Available Wound complications following ankle fracture surgery are a major concern. Through the use of minimally invasive surgical techniques some of these complications can be mitigated. Recent investigations have reported on percutaneous fixation of distal fibula fractures demonstrating similar radiographic and functional outcomes to traditional open approaches. The purpose of this manuscript is to describe in detail the minimally invasive surgical approach for distal fibula fractures.

  8. Minimally-invasive plate osteosynthesis in distal tibial fractures: Results and complications.

    Science.gov (United States)

    Vidović, Dinko; Matejčić, Aljoša; Ivica, Mihovil; Jurišić, Darko; Elabjer, Esmat; Bakota, Bore

    2015-11-01

    Distal tibial or pilon fractures are usually the result of combined compressive and shear forces, and may result in instability of the metaphysis, with or without articular depression, and injury to the soft tissue. The complexity of injury, lack of muscle cover and poor vascularity make these fractures difficult to treat. Surgical treatment of distal tibial fractures includes several options: external fixation, IM nailing, ORIF and minimally-invasive plate osteosynthesis (MIPO). Management of distal tibial fractures with MIPO enables preservation of soft tissue and remaining blood supply. This is a report of a series of prospectively studied closed distal tibial and pilon fractures treated with MIPO. A total of 21 patients with closed distal tibial or pilon fractures were enrolled in the study between March 2008 and November 2013 and completed follow-up. Demographic characteristics, mechanism of injury, time required for union, ankle range of motion and complications were recorded. Fractures were classified according to the AO/OTA classification. Nineteen patients were initially managed with an ankle-spanning external fixator. When the status of the soft tissue had improved and swelling had subsided enough, a definitive internal fixation with MIPO was performed. Patients were invited for follow-up examinations at 3 and 6 weeks and then at intervals of 6 to 8 weeks until 12 months. Mean age of the patients was 40.1 years (range 19-67 years). Eighteen cases were the result of high-energy trauma and three were the result of low-energy trauma. According to the AO/OTA classification there were extraarticular and intraarticular fractures, but only simple articular patterns without depression or comminution. The average time for fracture union was 19.7 weeks (range 12-38 weeks). Mean range of motion was 10° of dorsiflexion (range 5-15°) and 28.3° of plantar flexion (range 20-35°). Three cases were metalwork-related complications. Two patients underwent plate removal

  9. Subtrochanteric and Distal Femur Fractures in a Patient with ...

    African Journals Online (AJOL)

    This study reports the surgical management for this rare case and the treatment ... car accident and presented closed femoral shaft fracture associated with a ... to fix the distal femur fracture, enhancing the construction stability [Figures 4 and 5].

  10. Injuries of the scapholunate and lunotriquetral ligaments as well as the TFCC in intra-articular distal radius fractures. Prevalence assessed with MDCT arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Klempka, A.; Wagner, M.; Fodor, S.; Schmitt, R. [Cardiovascular Center Bad Neustadt an der Saale, Department of Diagnostic and Interventional Radiology, Bad Neustadt an der Saale (Germany); Prommersberger, K.J. [Clinic for Hand Surgery, Bad Neustadt an der Saale (Germany); Uder, M. [Friedrich-Alexander-University Erlangen-Nuernberg (FAU), Department of Diagnostic Radiology, Erlangen (Germany)

    2016-03-15

    To evaluate the prevalence of injuries of the scapholunate and lunotriquetral interosseous ligaments (SLIL, LTIL) as well as the triangular fibrocartilage complex (TFCC) in intra-articular distal radius fractures (iaDRF). Two hundred and thirty-three patients with acute iaDRF underwent MDCT arthrography. The SLIL and LTIL were described as normal, partially or completely ruptured. Major injuries of the SLIL were defined as completely ruptured dorsal segments, those of the LTIL as completely ruptured palmar segments. The TFCC was judged as normal or injured. Interobserver variability was calculated. Injury findings were correlated with the types of iaDRF (AO classification). In 159 patients (68.2 %), no SLIL injuries were seen. Minor SLIL injuries were detected in 54 patients (23.2 %), major injuries in 20 patients (8.6 %). No correlation was found between the presence of SLIL lesions and the types of iaDRF. Minor LTIL injuries were seen in 23 patients (9.9 %), major injuries in only 5 patients (2.2 %). The TFCC was altered in 141 patients (60.5 %). Interobserver variability was high for MDCT arthrography in assessing SLIL and TFC lesions, and fair for LTIL lesions. In iaDRF, prevalence of major injuries of the most relevant SLIL is about 9 % as evaluated with CT arthrography. (orig.)

  11. Distal radioulnar joint injuries

    Directory of Open Access Journals (Sweden)

    Binu P Thomas

    2012-01-01

    Full Text Available Distal radioulnar joint is a trochoid joint relatively new in evolution. Along with proximal radioulnar joint , forearm bones and interosseous membrane, it allows pronosupination and load transmission across the wrist. Injuries around distal radioulnar joint are not uncommon, and are usually associated with distal radius fractures,fractures of the ulnar styloid and with the eponymous Galeazzi or Essex_Lopresti fractures. The injury can be purely involving the soft tissue especially the triangular fibrocartilage or the radioulnar ligaments.The patients usually present with ulnar sided wrist pain, features of instability, or restriction of rotation. Difficulty in carrying loads in the hand is a major constraint for these patients. Thorough clinical examination to localize point of tenderness and appropriate provocative tests help in diagnosis. Radiology and MRI are extremely useful, while arthroscopy is the gold standard for evaluation. The treatment protocols are continuously evolving and range from conservative, arthroscopic to open surgical methods. Isolated dislocation are uncommon. Basal fractures of the ulnar styloid tend to make the joint unstable and may require operative intervention. Chronic instability requires reconstruction of the stabilizing ligaments to avoid onset of arthritis. Prosthetic replacement in arthritis is gaining acceptance in the management of arthritis.

  12. A Technique of Distal Clavicle Fracture Fixation Using The Tightrope Procedure

    Directory of Open Access Journals (Sweden)

    CJ Soh

    2011-11-01

    Full Text Available We present here a technique of fracture stabilization using the Tightrope procedure in a patient with a widely displaced Neer type IIB distal clavicle fracture. The Tightrope system, typically used for stabilization of acromioclavicular joint dislocation, has not been widely described for distal clavicle fractures. The patient achieved satisfactory results after surgery; we feel that this technique is appealing as it is simple, reproducible and avoids the complications associated with extensive metalwork. This technique may also appeal to the arthroscopic surgeon.

  13. Prevention of distal extension cantilever fracture in mandibular overdentures.

    Science.gov (United States)

    Quirynen, Thomas; Quirynen, Marc; Duyck, Joke

    2015-09-01

    Fractures of distal bar extensions, supporting a mandibular overdenture, do occur with significant functional and economic consequences for the patient. This study therefore aims to evaluate the effect of different bar cross-sectional shapes and surfaces, bar extension lengths and the placement of a support rib under the distal bar extension on fracture resistance. The 2nd moment area and static strength were calculated for 11 frequently used bar designs using finite element analysis (FEA). For two specific designs (Ackermann round Ø 1.8mm and Dolder-Y macro, the former with and without a support rib) additional physical static and fatigue strength tests were included. The FEA static strength data corresponded well to the 2nd moment area (a similar ranking when maximum allowed force was considered). The application of a rib support (Ackermann Ø 1.8mm) and limitations of the bar extension length (6mm for the Ackermann Ø 1.8mm, 8mm for the Dolder-Y macro) allowed the bars to exceed 5 × 10(6) cycles of 120 and 250N, respectively, before fracture. The region of highest stresses in FEA corresponded well with the locations of the fractures observed in static- and fatigue-testing. With some simple guidelines/modifications, the number of bar extension fractures can be reduced significantly. This study focusses on distal bar extensions which improve the positioning of an implant supported overdenture. By combining laboratory testing and finite element simulations we aim to: (1) explain why fractures occur (dependent on physical characteristics of the bar), and (2) give clinical guidelines on how to prevent such fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Imaging appearance of entrapped periosteum within a distal femoral Salter-Harris II fracture

    International Nuclear Information System (INIS)

    Chen, Johnathan; Abel, Mark F.; Fox, Michael G.

    2015-01-01

    Salter Harris II fractures of the distal femur are associated with a high incidence of complications, especially premature physeal closure. Many risk factors for this high rate of premature physeal closure have been proposed. More recently, entrapment of periosteum within the physis has been suggested as an additional predisposing factor for premature physeal closure. The radiographic diagnosis of entrapped soft tissues, including periosteum, can be suggested in the setting of a Salter-Harris II fracture when the fracture does not reduce and physeal widening >3 mm remains. We report a patient who sustained a distal femoral Salter-Harris II fracture following a valgus injury. The patient had persistent distal medial physeal widening >5 mm following attempted reduction. A subsequent MRI revealed a torn periosteum entrapped within the distal femoral physis. Following removal of the periosteum, the patient developed a leg length discrepancy which required physiodesis of the contralateral distal femur. We present this case to raise awareness of the importance of having a high index of suspicion of periosteal entrapment in the setting of Salter-Harris II fractures since most consider entrapped periosteum an indication for surgery. (orig.)

  15. CT-based three-dimensional kinematic comparison of dart-throwing motion between wrists with malunited distal radius and contralateral normal wrists

    International Nuclear Information System (INIS)

    Lee, S.; Kim, Y.S.; Park, C.S.; Kim, K.G.; Lee, Y.H.; Gong, H.S.; Lee, H.J.; Baek, G.H.

    2014-01-01

    Aim: To compare motion of the capitate, scaphoid, and lunate in wrists with a malunited distal radius and contralateral normal wrists during dart-throwing motion (DTM) by three-dimensional kinematic studies using computed tomography (CT) images. Materials and methods: CT was performed simultaneously on both wrists in six patients with a unilateral distal radius malunion at three stepwise positions simulating DTM. Using volume registration technique, the kinematic variables of helical axis motion of the capitate, scaphoid, and lunate were calculated and compared between both wrists. The helical motion of the capitate was also evaluated in a scaphoid- and lunate-based coordinate system. Results: Among the average rotation and translation of the scaphoid, lunate, and capitate during DTM, only the average rotation of the capitate was significantly different between the uninjured (88.9°) and the injured (70°) wrist (p = 0.0075). Rotation of the capitate relative to the scaphoid (26.3° versus 37.8°, p = 0.029) or lunate (39.2° versus 59.3°, p = 0.028) was smaller in the malunited wrist. The centres of helical axis motion of the three carpal bones were located more dorsally and radially in the injured wrist. Conclusions: The present study showed that decreased DTM in wrists with a distal radius malunion resulted from decreased midcarpal motion. The present study of the capitate, scaphoid, and lunate in wrists with distal radius malunion might be the first to present a 3D kinematic analysis of the effect of distal radius malunion on the carpal bones

  16. Minimally invasive plating osteosynthesis for mid-distal third humeral shaft fractures.

    Science.gov (United States)

    Lian, Kejian; Wang, Lei; Lin, Dasheng; Chen, Zhiwen

    2013-08-01

    Mid-distal third humeral shaft fractures can be effectively treated with minimally invasive plating osteosynthesis and intramedullary nailing (IMN). However, these 2 treatments have not been adequately compared. Forty-seven patients (47 fractures) with mid-distal third humeral shaft fractures were randomly allocated to undergo either minimally invasive plating osteosynthesis (n=24) or IMN (n=23). The 2 groups were similar in terms of fracture patterns, fracture location, age, and associated injuries. Intraoperative measurements included blood loss and operative time. Clinical outcome measurements included fracture healing, radial nerve recovery, and elbow and shoulder discomfort. Radiographic measurements included fracture alignment, time to healing, delayed union, and nonunion. Functional outcome was satisfactory in both groups. Mean American Shoulder and Elbow Surgeons score and Mayo score were both better for the minimally invasive plating osteosynthesis group than for the IMN group (98.2 vs 97.6, respectively, and 93.5 vs 94.1, respectively; Pshaft fractures. Minimally invasive plating osteosynthesis is more suitable for complex fractures, especially for radial protection and motion recovery of adjacent joints, compared with IMN for simple fractures. Copyright 2013, SLACK Incorporated.

  17. A PROSPECTIVE STUDY OF DISTAL TIBIAL FRACTURES BY MIPO (LCP)

    OpenAIRE

    Chandra Sekharam Naidu; Ch.Murali Krishna; Sankara Rao; Dharma Rao; Ashok Kumar

    2015-01-01

    INTRODUCTION: D istal tibial fractures represent a significant challenge to most of the surgeons even today. They constitute 1 - 10% of all lower extremity fractures . 1 The difficulty in treating the fractures of distal tibial end is exemplif ied by orthopedists, who in the first half of twentieth century, believed these injuries were so severe and fraught with so many complications, that these fractures wer...

  18. Retrograde nailing for distal femur fractures in the elderly

    Directory of Open Access Journals (Sweden)

    Giddie Jasdeep

    2015-01-01

    Full Text Available Introduction: We report the results of treating a series of 56 fractures in 54 elderly patients with a distal femur fracture with a retrograde femoral nail. Methods: Fifty-four of the nails were inserted percutaneously with a closed reduction. After surgery all patients were allowed to weight bear as tolerated. Four fractures were supported in a temporary external splint. Results: The mean age of patients was 80.6 years (range 51–103 years, 52/54 (96% were females. There were no cases of nail related complications and no re-operations were required. One patient was lost to follow up. The 30-day mortality was 5/54 (9.3% and the one year mortality was 17/54 (31.5%. Conclusions: Distal femoral nail fixation provides a good method of fixation allowing immediate mobilisation for this group of patients.

  19. Stress fracture as a complication of autogenous bone graft harvest from the distal tibia.

    Science.gov (United States)

    Chou, Loretta B; Mann, Roger A; Coughlin, Michael J; McPeake, William T; Mizel, Mark S

    2007-02-01

    Autogenous bone graft from the distal tibia provides cancellous bone graft for foot and ankle operations, and it has osteogenic and osteoconductive properties. The site is in close proximity to the foot and ankle, and published retrospective studies show low morbidity from the procedure. One-hundred autografts were obtained from the distal tibia between 2000 and 2003. In four cases the distal tibial bone graft harvest resulted in a stress fracture. There were three women and one man. The average time of diagnosis of the stress fracture from the operation was 1.8 months. All stress fractures healed with a short course (average 2.4 months) of cast immobilization. This study demonstrated that a stress fracture from the donor site of autogenous bone graft of the distal tibia occurs and can be successfully treated nonoperatively.

  20. Early functional postoperative therapy of distal radius fracture with a dynamic orthosis: results of a prospective randomized cross-over comparative study.

    Directory of Open Access Journals (Sweden)

    Fabian M Stuby

    Full Text Available This study was conducted according to GCP criteria as a prospective randomized cross-over study. The primary goal of the study was to determine clinical findings and patient satisfaction with postoperative treatment. 29 patients with a distal radius fracture that was surgically stabilized from volar and who met the inclusion criteria were enrolled over a 12-month period. Each patient randomly received either a dorsal plaster splint or a vacuum-fit flexible but blocked orthosis applied postoperatively in the operating theatre to achieve postoperative immobilization. After one week all patients were crossed over to the complementary device maintaining the immobilization until end of week 2. After week 2 both groups were allowed to exercise wrist mobility with a physiotherapist, in the orthosis group the device was deblocked, thus allowing limited wrist mobility. After week 4 the devices were removed in both groups. Follow-up exams were performed after postoperative weeks 1, 2, 4 and 12.Results were determined after week 1 and 2 using SF 36 and a personally compiled questionnaire; after weeks 4 and 12 with a clinical check-up, calculation of ROM and the DASH Score. Comparison of the two groups showed a significant difference in ROM for volar flexion after 4 weeks, but no significant differences in DASH Score, duration of disability or x-ray findings. With regard to satisfaction with comfort and hygiene, patients were significantly more satisfied with the dynamic orthosis, and 23 of the 29 patients would prefer the flexible vacuum orthosis in future.German Clinical Trials Register (DRKS DRKS00006097.

  1. Total elbow arthroplasty for the treatment of distal humeral fractures.

    Science.gov (United States)

    Gallucci, G L; Larrondo Calderón, W; Boretto, J G; Castellaro Lantermo, J A; Terán, J; de Carli, P

    2016-01-01

    To report the clinical-functional outcomes of the treatment of humeral distal fractures with a total elbow prosthesis. This retrospective study was performed in two surgical centres. A total of 23patients were included, with a mean age of 79years, and of which 21 were women. The inclusion criteria were: patients with humeral distal fractures, operated on using a Coonrad-Morrey prosthesis, and with a follow-up of more than one year. According to AO classification, 15fractures were type C3, 7 C2 and 1 A2. All patients were operated on without de-insertion of the extensor mechanism. The mean follow-up was 40 months. Flexor-extension was 123-17°, with a total mobility arc of 106° (80% of the contralateral side). Pain, according to a visual analogue scale was 1. The Mayo Elbow Performance Index (MEPI) was 83 points. Excellent results were obtained in 8 patients, good in 13, medium in 1, and poor in 1. The mean DASH (disability) score was 24 points. Treatment of humeral distal fractures with total elbow arthroplasty could be a good treatment option, but indications must be limited to patients with complex fractures, poor bone quality, with osteoporosis and low functional demands. In younger patients, the use is limited to serious cases where there is no other treatment option. Level of Evidence IV. Copyright © 2016 SECOT. Published by Elsevier Espana. All rights reserved.

  2. The Effect of Isometric Massage on Global Grip Strength after Conservative Treatment of Distal Radial Fractures. Pilot Study.

    Science.gov (United States)

    Ratajczak, Karina; Płomiński, Janusz

    2015-01-01

    The most common fracture of the distal end of the radius is Colles' fracture. Treatment modalities available for use in hand rehabilitation after injury include massage. The aim of this study was to evaluate the effect of isometric massage on the recovery of hand function in patients with Colles fractures. For this purpose, the strength of the finger flexors was assessed as an objective criterion for the evaluation of hand function. The study involved 40 patients, randomly divided into Group A of 20 patients and Group B of 20 patients. All patients received physical therapy and exercised individually with a physiotherapist. Isometric massage was additionally used in Group A. Global grip strength was assessed using a pneumatic force meter on the first and last day of therapy. Statistical analysis was performed using STATISTICA. Statistical significance was defined as a P value of less than 0.05. In both groups, global grip strength increased significantly after the therapy. There was no statistically significant difference between the groups. The men and women in both groups equally improved grip strength. A statistically significant difference was demonstrated between younger and older patients, with younger patients achieving greater gains in global grip strength in both groups. The incorporation of isometric massage in the rehabilitation plan of patients after a distal radial fracture did not significantly contribute to faster recovery of hand function or improve their quality of life.

  3. Intramedullary nailing of proximal and distal one-third tibial shaft fractures with intraoperative two-pin external fixation.

    Science.gov (United States)

    Wysocki, Robert W; Kapotas, James S; Virkus, Walter W

    2009-04-01

    Fractures of the proximal and distal one thirds of the tibial shaft have historically higher malunion rates than those of the midshaft. This retrospective case series evaluates the postoperative radiographic outcome of intramedullary nailing of proximal and distal one-third tibial shaft fractures using intraoperative two-pin external fixation, often referred to as traveling traction. Between 2000 and 2005, 15 consecutive patients with proximal third and 27 consecutive patients with distal third displaced extra-articular fractures of the tibia were treated with statically locked intramedullary nailing and supplementary intraoperative two-pin rectangular frame external fixation. The external fixation was removed once the proximal and distal locking screws were in place. The alignment of the fractures was determined using standard postoperative anteroposterior and lateral radiographs. Postoperatively, 14 of 15 patients with proximal fractures and 25 of 27 patients with distal fractures had less than 5 degrees of angular deformity in both the coronal and sagittal planes and less than 1 cm shortening. Statically locked intramedullary nailing with simultaneous intraoperative traveling traction external fixation as treatment for proximal and distal one-third extra-articular tibial shaft fractures is successful in achieving a high rate of acceptable postoperative alignment.

  4. Outcomes of the distal intraarticular humeral fractures treated by olecranon osteotomy

    Directory of Open Access Journals (Sweden)

    Erhan Yılmaz

    2009-01-01

    Full Text Available Objectives: To evaluate the management and outcome of intraarticular fractures of the distal humerus treated by open reduction and internal fixation using the olecranon osteotomy technique. Materials and methods: Twenty-one patients with in-traarticular fractures of the distal humerus were treated by open reduction and internal fixation. The mean age of the patients was 41.6 years and the mean follow-up pe-riod was 25.3 months. All fractures were type C accord-ing to the AO/ASIF fracture classification system. Chev-ron type olecranon osteotomy was performed within 12-24 h after the injury in all cases but 4 of them. Physical and radiological examination of patients with the appro-priate range checks were made.Results: All fractures united within average duration of 3.2 months. Excellent or good results were found in pa-tients less than 50 years-old, in women, when passing time from injury to surgery was within 12 hours and when early mobilization was achieved. The complica-tions were seen as 2 (9.6% transient neuropraxia of the ulnar nerve, 2 (9.6% failure of fixation, 1 (4.8% het-erotopic ossification and 1 (4.8% olecranon non-union. Fracture type (C1 and time from occurrence of injury to surgery (<12 hours are the main prognostic factors for achieving the excellent/ good functional results.Conclusions: The critical factors for a successful out-come of intraarticular fractures of the distal humerus in-cluded meticulous surgical technique, stable internal fix-ation, surgical experimentation and early controlled postoperative mobilization.

  5. Daily number of fractures is associated with road temperature in an urban area

    DEFF Research Database (Denmark)

    Jantzen, Christopher; Jørgensen, Henrik L; Thomsen, Morten

    2014-01-01

    winters. MATERIAL AND METHODS: Retrospective data collection was conducted on all patients treated at Bispebjerg Hospital, Denmark, for a humeral, ankle, distal radius or hip fracture during the periods October to April 2009/2010 and 2010/2011. Patients were grouped according to age into the following......,938 fractures) were treated during the study periods. The daily number of distal radius, humeral and ankle fractures increased significantly with decreasing road surface temperature and the presence of IA. For hip fractures no significant association was found. Decreasing temperature was associated......INTRODUCTION: Different factors related to winter are known to influence the fracture incidence, but little is known about the effect of road surface temperature. This study examines the association between road surface temperature and the daily number of fractures in an urban area during two...

  6. A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

    Directory of Open Access Journals (Sweden)

    Prakash Jayakumar

    2015-04-01

    Full Text Available Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking screw, which must also avoid the olecranon, coronoid, and radial fossae. We describe 3 patients (ages 27, 49, and 73 years with a bicolumnar fracture of the distal humerus where very short distal locking screws were used. Intra-articular screw placement was avoided but loss of fixation occurred in two patients and a third was treated with a prolonged period of immobilization. We postulate that fixed-angle screw trajectories may make it difficult for the surgeon to place screws of adequate length in this anatomically confined region, and may lead to insufficient distal fixation. Surgical tactics should include placement of as many screws as possible into the distal fragment, as long as possible, and that each screw pass through a plate without necessarily locking in.

  7. early functional outcome of distal femoral fractures at kenyatta

    African Journals Online (AJOL)

    The leading cause was RTA, followed by falls from a height. ... Distal femoral fractures cause considerable morbidity .... as means and standard deviations. .... Anaesthesia. Spinal. 37 (80). General Anaesthesia (GA). 9 (20). Transfusion.

  8. Locking internal fixator with minimally invasive plate osteosynthesis for the proximal and distal tibial fractures

    Directory of Open Access Journals (Sweden)

    TONG Da-ke

    2012-02-01

    Full Text Available 【Abstract】Objective: To investigate the efficacy of the locking internal fixator (LIF, which includes the locking compression plate (LCP and the less invasive stable system (LISS, in the proximal and distal tibial fractures. Methods: We did a retrospective study on a total of 98 patients with either proximal or distal tibial fractures from January 2003 to January 2007, who had received the opera- tion with LIF by the minimally invasive plate osteosynthesis (MIPO technique. The data consisted of 43 proximal tibial fractures (type AO41C3 and 55 distal tibial fractures (type AO43C3. Results: No complications were observed in all patients after operation. The mean healing time was 8.4 months (range 5-14 months. Only two cases of delayed union occurred at postoperative 10 months. No infections were reported after the definitive surgery even in the cases of open fractures. All patients reached a full range of motion at postoperative 6 to 9 months and regained the normal functions of knee and ankle joints. Conclusion: Using LIF in MIPO technique is a reliable approach towards the proximal and distal tibial fractures that are not suitable for intramedullary nailing. Key words: Internal fixator; Tibial fractures; Fracture fixation, intramedullary; Bone plates

  9. [Frequency of diagnosis of postmenopausal osteoporosis of the spine, distant radius and extravertebral fractures in women with normal body mass, overweight and obesity].

    Science.gov (United States)

    Popov, A A; Izmozherova, N V; Fominykh, M I; Tagil'tseva, N V; Kozulina, E V; Gavrilova, E I

    2008-01-01

    To assess features and peculiarities of postmenopausal osteoporosis (OP) in women with normal body mass, overweight and obesity. Dual energy X-ray absorptiometry of the lumbal spine (Lunar DPX) and distal radius X-ray absorptiometry (DTX 200) were performed during cross-section study of 730 symptomatic postmenopausal women. OP was diagnosed in 253 (34.7%) women, 30.5% of them had normal body mass, 43.2% had overweight and 26.3% were obese. Among them 227 had atraumatic fractures at the age over 50 years. Obese OP patients had significantly higher frequency of arterial hypertension, chronic heart failure, osteoarthritis and glucose metabolism disorders than osteoporotic patients with normal body mass. Fracture frequency did not differ between groups with normal body mass, overweight and obesity. Excessive body mass did not decrease fracture risk in women with postmenopausal OP.

  10. Changes in Depression, Health Anxiety, and Pain Catastrophizing Between Enrollment and 1 Month After a Radius Fracture.

    Science.gov (United States)

    Golkari, Sina; Teunis, Teun; Ring, David; Vranceanu, Ana-Maria

    2015-01-01

    To test the difference in symptoms of (1) depression, (2) health anxiety, and (3) catastrophic thinking between 1 and 6 weeks after injury to the radius. In total, 69 adult patients with a minimally displaced radial head or distal radius fracture were prospectively enrolled. After diagnosis, we recorded demographic variables, 11-point ordinal numerical pain score, and agreement with "no pain, no gain"; Disabilities of the Arms, Shoulder, and Hand (DASH) questionnaire; Center for Epidemiologic Studies Depression Scale; the Whiteley Index; and the Pain Catastrophizing Scale. In total, 55 patients (80%) returned after 1 month to reevaluate pain, Disabilities of the Arms, Shoulder, and Hand, Center for Epidemiologic Studies Depression, Whiteley Index, and Pain Catastrophizing Scale scores. Center for Epidemiologic Studies Depression scores decreased by an average of 5 ± 9 points (p psychologic measures are used as a screening tool to predict outcome after treatment, one should account for a patient's disease phase. Prognostic level I. Copyright © 2015 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  11. Intramodality and intermodality agreement in radiography and computed tomography of equine distal limb fractures.

    Science.gov (United States)

    Crijns, C P; Martens, A; Bergman, H-J; van der Veen, H; Duchateau, L; van Bree, H J J; Gielen, I M V L

    2014-01-01

    Computed tomography (CT) is increasingly accessible in equine referral hospitals. To document the level of agreement within and between radiography and CT in characterising equine distal limb fractures. Retrospective descriptive study. Images from horses that underwent radiographic and CT evaluation for suspected distal limb fractures were reviewed, including 27 horses and 3 negative controls. Using Cohen's kappa and weighted kappa analysis, the level of agreement among 4 observers for a predefined set of diagnostic characteristics for radiography and CT separately and for the level of agreement between the 2 imaging modalities were documented. Both CT and radiography had very good intramodality agreement in identifying fractures, but intermodality agreement was lower. There was good intermodality and intramodality agreement for anatomical localisation and the identification of fracture displacement. Agreement for articular involvement, fracture comminution and fracture fragment number was towards the lower limit of good agreement. There was poor to fair intermodality agreement regarding fracture orientation, fracture width and coalescing cracks; intramodality agreement was higher for CT than for radiography for these features. Further studies, including comparisons with surgical and/or post mortem findings, are required to determine the sensitivity and specificity of CT and radiography in the diagnosis and characterisation of equine distal limb fractures. © 2013 EVJ Ltd.

  12. Minimally invasive locked plating of distal tibia fractures is safe and effective.

    Science.gov (United States)

    Ronga, Mario; Longo, Umile Giuseppe; Maffulli, Nicola

    2010-04-01

    Distal tibial fractures are difficult to manage. Limited soft tissue and poor vascularity impose limitations for traditional plating techniques that require large exposures. The nature of the limitations for traditional plating techniques is intrinsic to the large exposure required to approach distal tibia, a bone characterized by limited soft tissue coverage and poor vascularity. The locking plate (LP) is a new device for treatment of fractures. We assessed the bone union rate, deformity, leg-length discrepancy, ankle range of motion, return to preinjury activities, infection, and complication rate in 21 selected patients who underwent minimally invasive osteosynthesis of closed distal tibia fractures with an LP. According to the AO classification, there were 12 Type A, 5 Type B, and 4 Type C fractures. The minimum followup was 2 years (average, 2.8 years; range, 2-4 years). Two patients were lost to followup. Union was achieved in all but one patient by the 24th postoperative week. Four patients had angular deformity less than 7 degrees . No patient had a leg-length discrepancy more than 1.1 cm. Five patients had ankle range of motion less than 20 degrees compared with the contralateral side. Sixteen patients had not returned to their preinjury sporting or leisure activities. Three patients developed a delayed infection. We judge the LP a reasonable device for treating distal tibia fractures. The level of physical activities appears permanently reduced in most patients. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  13. Alterations of bone density, microstructure, and strength of the distal radius in male patients with rheumatoid arthritis: a case-control study with HR-pQCT.

    Science.gov (United States)

    Zhu, Tracy Y; Griffith, James F; Qin, Ling; Hung, Vivian W; Fong, Tsz-Ning; Au, Sze-Ki; Li, Martin; Lam, Yvonne Yi-On; Wong, Chun-Kwok; Kwok, Anthony W; Leung, Ping-Chung; Li, Edmund K; Tam, Lai-Shan

    2014-09-01

    In this cross-sectional study, we investigated volumetric bone mineral density (vBMD), bone microstructure, and biomechanical competence of the distal radius in male patients with rheumatoid arthritis (RA). The study cohort comprised 50 male RA patients of average age of 61.1 years and 50 age-matched healthy males. Areal BMD (aBMD) of the hip, lumbar spine, and distal radius was measured by dual-energy X-ray absorptiometry. High-resolution peripheral quantitative computed tomography (HR-pQCT) of the distal radius provided measures of cortical and trabecular vBMD, microstructure, and biomechanical indices. aBMD of the hip but not the lumbar spine or ultradistal radius was significantly lower in RA patients than controls after adjustment for body weight. Total, cortical, and trabecular vBMD at the distal radius were, on average, -3.9% to -23.2% significantly lower in RA patients, and these differences were not affected by adjustment for body weight, testosterone level, or aBMD at the ultradistal radius. Trabecular microstructure indices were, on average, -8.1% (trabecular number) to 28.7% (trabecular network inhomogeneity) significantly inferior, whereas cortical pore volume and cortical porosity index were, on average, 80.3% and 63.9%, respectively, significantly higher in RA patients. RA patients also had significantly lower whole-bone stiffness, modulus, and failure load, with lower and more unevenly distributed cortical and trabecular stress. Density and microstructure indices significantly correlated with disease activity, severity, and levels of pro-inflammatory cytokines (interleukin [IL] 12p70, tumor necrosis factor, IL-6 and IL-1β). Ten RA patients had focal periosteal bone apposition most prominent at the ulnovolar aspect of the distal radius. These patients had shorter disease duration and significantly higher cortical porosity. In conclusion, HR-pQCT reveals significant alterations of bone density, microstructure, and strength of the distal radius in

  14. Transfixation pinning and casting of radial-ulnar fractures in calves: A review of three cases

    OpenAIRE

    St-Jean, Guy; Debowes, Richard M.

    1992-01-01

    We reviewed the medical records of three calves with radial-ulnar fractures which were reduced and stabilized by transfixation pinning and casting. Multiple Steinmann pins were placed transversely through proximal and distal fracture fragments and the pin ends were incorporated in fiberglass cast material after fracture reduction. Cast material was placed from proximal to distal radius and served as an external frame to maintain pin position and fracture reduction.

  15. Closed treatment of overriding distal radial fractures without reduction in children.

    Science.gov (United States)

    Crawford, Scott N; Lee, Lorrin S K; Izuka, Byron H

    2012-02-01

    Traditionally, distal radial fractures with marked displacement and angulation have been treated with closed or open reduction techniques. Reduction maneuvers generally require analgesia and sedation, which increase hospital time, cost, patient risk, and the surgeon's time. In our study, a treatment protocol for pediatric distal radial fractures was used in which the fracture was left shortened in an overriding position and a cast was applied without an attempt at anatomic fracture reduction. Consecutive patients three to ten years of age presenting between 2004 and 2009 with a closed overriding fracture of the distal radial metaphysis were followed prospectively. Our protocol consisted of no analgesia, no sedation, and a short arm fiberglass cast gently molded to correct only angulation. Patients were followed for at least one year. All parents or guardians were given a questionnaire assessing their satisfaction with the treatment. Financial analysis was performed with use of Current Procedural Terminology codes and the average total cost of care. Fifty-one children with an average age of 6.9 years were included in the study. Initial radial shortening averaged 5.0 mm. Initial sagittal and coronal angulation averaged 4.0° and 3.2°, respectively. The average duration of casting was forty-two days. Residual sagittal and coronal angulation at the time of final follow-up averaged 2.2° and 0.8°, respectively. All fifty-one patients achieved clinical and radiographic union with a full range of wrist motion. All parents and guardians answered the questionnaire and were satisfied with the treatment. Cost analysis demonstrated that closed reduction with the patient under conscious sedation or general anesthesia is nearly five to six times more expensive than the treatment used in this study. Adding percutaneous pin fixation increases costs nearly ninefold. This treatment protocol presents an alternative approach to overriding distal radial fractures in children and

  16. Percutaneous Screw Fixation of Distal Tibia Fractures – Functional Results in Sixteen Patients

    OpenAIRE

    Kaftandziev, Igor; Trpeski, Simon; Arsovski, Oliver; Spasov, Marko

    2014-01-01

    INTRODUCTION: An important feature of distal tibia fractures is the relevance of the soft tissue coverage. In order to maintain good functional outcome, several operative techniques have been established. Among them, percutaneous screw fixation has the advantage of causing less biological damage of the soft tissues with lower rates of complications. MATERIAL AND METHODS: We reviewed 16 patients with distal tibia fracture. Operative treatment consisted of indirect reduction and percutaneou...

  17. Isolated fracture of pisiform: case report of a rare injury of wrist

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    ABSTRACT: Isolated fracture of the pisiform is an extremely rare injury. Generally fractures of the pisiform are associated with fractures of other carpal bones or the distal radius. Fractures of the carpals and metacarpals account for roughly 6% of all fractures. The average incidence of pisiform fractures is 0.2% of all carpal ...

  18. Incidence of palmar process fractures of the distal phalanx and association with front hoof conformation in foals.

    Science.gov (United States)

    Faramarzi, B; McMicking, H; Halland, S; Kaneps, A; Dobson, H

    2015-11-01

    Recent studies indicate a high prevalence of fractures of the palmar processes (PP) of the distal phalanx in foals. However, information on the prevalence of such fractures in different breeds and the effect of predisposing factors, such as hoof conformation, is limited. To examine the prevalence of distal phalanx PP fractures in foals and report the relationship of distal limb and hoof conformation with the prevalence of fracture. Longitudinal study. Front hooves of 19 Thoroughbred, Quarter Horse and Arabian foals were examined. Digital radiographic and photographic images of the distal aspect of the forelimbs were taken at ∼2.5 month intervals. Five radiographic projections of each limb were as follows: lateromedial; horizontal beam dorsopalmar; dorso60°proximal-palmarodistal oblique; dorso60°proximo45°lateral-palmarodistomedial oblique; and dorso60°proximo45°medial-palmarodistolateral oblique. The relationship between measurements and the prevalence of fractures was assessed by 3-way ANOVA. Fractures were found in 74% (n = 14) of the foals during the study period. The prevalences of lateral PP and medial PP fractures were not significantly different. Several hoof measurements were associated with PP fractures. Longer dorsal length of the distal phalanx was associated with medial PP fractures, while smaller lateral angle and shorter lateral palmar length were associated with a higher prevalence of lateral PP fractures. This study revealed a high prevalence of PP fractures in young foals, particularly in Thoroughbred foals. The hoof conformation may be one of the contributory factors to PP fractures in foals. © 2014 EVJ Ltd.

  19. Uncemented three-dimensional-printed prosthetic replacement for giant cell tumor of distal radius: a new design of prosthesis and surgical techniques.

    Science.gov (United States)

    Lu, Minxun; Min, Li; Xiao, Cong; Li, Yongjiang; Luo, Yi; Zhou, Yong; Zhang, Wenli; Tu, Chongqi

    2018-01-01

    Currently, it is challenging to treat giant cell tumor (GCT) of distal radius. For Campanacci grade III or recurrent GCTs, en bloc resection has been accepted as a better treatment option. Although numerous methods are available for reconstruction, all of them have some limitations in joint function and complications. In this study, our aims were to treat the GCT of distal radius with uncemented three-dimensional (3D)-printed prosthesis and to present and evaluate the surgical techniques and short-term outcomes. Between September 2015 and March 2017, 11 patients with distal radius GCTs were treated with personalized uncemented 3D-printed prosthesis. The preoperative/postoperative pain, range of motion, and grip strengths of all patients were evaluated. Oncological results, complications, and degenerative changes in the wrist joint were evaluated. Functional outcomes were assessed according to the disabilities of the arm, shoulder, and hand (DASH) questionnaire and Mayo wrist scoring systems. The average follow-up was 14.45 months (range, 8-18 months). There was a significant decrease in the mean postoperative visual analog scale score (2.33) compared with the preoperative score (5.22; p 3D-printed prosthesis can be alternative options to treat Campanacci grade III or recurrent GCTs of distal radius and can result in short-term oncologic salvage, good postoperative function, and low complication rate. However, a long-term follow-up is required to determine the outcome.

  20. Antero-medial approach to the wrist: anatomic basis and new application in cases of fracture of the lunate facet.

    Science.gov (United States)

    Uzel, A-P; Bulla, A; Laurent-Joye, M; Caix, P

    2011-08-01

    The Henry approach is the classical anterolateral surgical exposure of the volar aspect of the distal radius. This approach does not allow good access to the medial side of the volar distal radius (lunate facet) and the distal radio-ulnar joint, unless it is extended proximally, retracting the tendons and the median nerve medially, which can cause some trauma. The purpose of our study was to investigate the anatomic basis and to outline the advantages of the unusual anteromedial approach, reporting our experience in the treatment of 4 distal radius fractures, with a 90° or 180° twist of the lunate facet, and 10 wrist dissections on cadavers. The average follow-up was 68.8 months (range 18 to 115 months). In our series, this approach did not cause any nerve injuries or any sensory loss of the distal forearm and the palm. All the fractures of the lunate facet and of the radial styloid process healed. One patient with an ulnar styloid process fracture associated showed pseudarthrosis, but with no instability of the distal radio-ulnar joint or pain on the ulnar side. Using the criteria of Green and O'Brien, modified by Cooney, the results were: excellent in two cases, good in one case, and average in another. The evaluation of arthritis according to Knirk and Jupiter's classification showed grade 0 in three cases and grade 3 in one case with osteochondral sclerosis. We showed that the anteromedial approach is reliable and convenient in the case of fractures situated in the antero-medial portion of the radius, for the double objective of reducing the fracture under direct control and checking the congruence of the distal radio-ulnar joint.

  1. Use of Relative vs Fixed Offset Distance to Define Region of Interest at the Distal Radius and Tibia in High-Resolution Peripheral Quantitative Computed Tomography

    DEFF Research Database (Denmark)

    Shanbhogue, Vikram V; Hansen, Stinus; Halekoh, Ulrich

    2015-01-01

    adjacent to the measurement site. This study aimed at compare the morphologic variation in measurements using the standard fixed offset distance to define the distal starting slice against those obtained by using a relative measurement position scaled to the individual bone length at the distal radius...... defined by, first, the standard measurement protocol, where the most distal CT slice was 9.5 mm and 22.5 mm from the end plate of the radius and tibia, respectively, and second, the relative measurement method, where the most distal CT slice was at 4% and 7% of the radial and tibial lengths, respectively....... Volumetric densities and microarchitectural parameters were compared between the 2 methods. Measurements of the total and cortical volumetric density and cortical thickness at the radius and tibia and cortical porosity, trabecular volumetric density, and trabecular number at the tibia were significantly...

  2. Distal tibial fracture treated by minimally invasive plate osteosynthesis after external fixation Retrospective clinical and radiographic assessment

    Directory of Open Access Journals (Sweden)

    Al. Șerban

    2014-02-01

    Full Text Available Fractures of the horizontal surface of the distal tibia are known commonly as pylon or plafond fractures, and represent 1-5% of lower extremity fractures, 7-10% of all tibial fractures. The protocol consisted of immediate (within eight to 24 hours open reduction and internal fixation of the fibula, using a fibular plate or one third tubular plate and application of an external fixator spanning the ankle joint. In the second stage, the treatment of proximal and distal tibial fractures with close reduction and MIPPO technique can preserve soft tissue, simplify operative procedure and decrease wound, obtain rigid internal fixation and guarantee early function exercises of ankle joint. In this study we evaluated 22 patients treated in Clinical Emergency Hospital Constanta between April 2012 - July 2013 diagnosed with multifragmentary fractures of the distal tibia. This study evaluates the treatment of complex fractures of distal tibia with locked plate after external fixation. There were 17 males and 5 females of mean age 51,7 years (31-68. The mean follow-up period was 14 weeks. (Ranging from 9-16 weeks. All patients were fully weight bearing at 16 weeks (ranging 9-16 weeks showing radiological union. There were no cases of failures of fixation, or rotational misalignment. No significant complication was observed in our patients. MIPO is an effective method of treatment for distal tibial fractures, reduce surgical trauma and maintain a more biologically favorable environment for fracture healing, reducing risks of infection and nonunion.

  3. Outcomes of Distal Femur Fracture Treated with Dynamic Condylar Screw

    International Nuclear Information System (INIS)

    Razaq, M. N. U.; Muhammad, T.; Ahmed, A.; Adeel, M.; Ahmad, S.; Ahmad, S.; Sultan, S.

    2016-01-01

    Background: Implants for open reduction and internal fixation of distal femoral fracture includes angle blade plate, rush nails, enders nail and interlocking nails. But all these devices are technically demanding and less effective in providing inter-fragmentary compression in osteoporotic bones. These problems can be solved with dynamic condylar screw (DCS).The objective of the study was to determine the frequency of different outcomes of distal femoral fracture treated with dynamic condylar screw Methods: This case series study was carried out in the Department of Trauma and Orthopaedics, Ayub Teaching Hospital Abbottabad from 1st October 2014 to August 2015, after approval of the ethical committee of the institution. Data of all patients with distal femoral fractures aged 20-70 years, recruited through emergency, OPD or consultant clinic collected on a proforma. Standard treatment of trauma was given to the patients. Detailed history was taken including the past medical and surgical history. Detailed examination including air-way, breathing and circulation, general physical examination and abdomino-pelvic examination was done in each patient. Investigations including urinalysis, haemoglobin percent, full blood count, X-ray (both AP and lateral view) of the involved femur (including hip and knee) was done. Results: Mean age of the patients was 43.18±14.647 ranging from 20 to 70 years. Mean duration of hospital stay in days was 2.21±1.111 ranging from 1 to 6 days. Patients follow-up assessment after 4 months of surgery for union of femoral fracture treated with dynamic condylar screw was found in 96 (94.1 percent), wound infection was found in 7 (6.9 percent), knee stiffness was found in 21 (20.6 percent) and limb shortening was found in 7 (6.9 percent). Conclusion: Dynamic condylar screw is an easy, scientifically less difficult and satisfying method of treatment for fractures of femur. (author)

  4. Does a distal forearm fracture lead to evaluation for osteoporosis? A retrospective cohort study in 147 Danish women

    DEFF Research Database (Denmark)

    Rud, Bo; Greibe, Rasmus; Hyldstrup, Lars

    2005-01-01

    In postmenopausal women, a low-trauma distal forearm fracture is a risk factor for osteoporosis and future fracture, which indicates osteoporosis follow-up according to prevailing guidelines. We decided to determine how often women over 45 yr presenting with a low-trauma distal forearm fracture t......, and it emphasizes the need to decide on a local level how to provide osteoporosis follow-up for women with fragility fractures. Udgivelsesdato: 2005 Spring......In postmenopausal women, a low-trauma distal forearm fracture is a risk factor for osteoporosis and future fracture, which indicates osteoporosis follow-up according to prevailing guidelines. We decided to determine how often women over 45 yr presenting with a low-trauma distal forearm fracture...... to a Danish emergency department during a 1-yr period were followed up for osteoporosis. We performed a retrospective review of hospital records and we sent the women and their general practitioners (GPs) questionnaires regarding the follow-up undertaken in primary care. Finally, we invited the women...

  5. Effect of Cortical Screw Diameter on Reduction and Stabilization of Type III Distal Phalanx Fractures: An Equine Cadaveric Study.

    Science.gov (United States)

    Kay, Alastair T; Durgam, Sushmitha; Stewart, Matthew; Joslyn, Stephen; Schaeffer, David J; Horn, Gavin; Kesler, Richard; Chew, Peter

    2016-11-01

    To compare reduction of type III distal phalangeal fractures using 4.5 and 5.5 mm cortical screws placed in lag fashion and an intact hoof capsule model. Cadaveric experimental study. Hooves from 12 adult horses (n=24). Sagittal fractures were created in pairs of distal phalanges after distal interphalangeal joint disarticulation and were reduced with either 4.5 or 5.5 mm cortical screws placed in lag fashion. Contralateral phalanges served as non-reduced controls. Fracture reduction following screw placement was assessed by comparing pre-reduction and post-reduction fracture gap measurements from radiographs using paired t-tests. Effects of incremental loading (0, 135, 270, 540, 800, 1070, and 1335 kg) on fracture gaps in 6 phalanges reduced with 4.5 mm screws and 5 phalanges reduced with 5.5 mm screws were measured from fluoroscopic images and assessed by 2-way ANOVA. Significance was set at Pfractures were reliably created. Only 5.5 mm cortical screws, not 4.5 mm screws, significantly reduced fracture gaps and constrained fracture gap expansion 3 cm distal to the articular surface. Compressive loading closed the fracture gaps at the articular surface in both non-reduced control groups and those reduced with either 5.5 or 4.5 mm screws. The 5.5 mm cortical screws were more effective than 4.5 mm screws in reducing type III distal phalanx fractures and restricting distal fracture gap expansion under load. © Copyright 2016 by The American College of Veterinary Surgeons.

  6. Total elbow arthroplasty in distal humerus fracture in patients older than 65 years.

    Directory of Open Access Journals (Sweden)

    Gerardo Gallucci

    2016-05-01

    Full Text Available Objective To report the clinical-functional results of the treatment of humeral distal fractures with a total elbow prosthesis in patients older than 65 years old. Material and methods This retrospective paper was performed in two surgical centers. Criteria inclusion were: patients with humeral distal fractures, > 65 years, operated on with Coonrad-Morrey prostheses, and with a follow-up of  >1 year. Twenty-one patients were included. Twenty were women with an average age of 79 years old. According to AO classification, 13 fractures were type C3, 7 C2 and 1 A2. All patientes were operated on without desinsertion of the extensor mechanism. Average follow-up was 40 months. Results Flexo-extension was 123-17°, with a total arc of mobility of 106° (80 % of the contralateral side. Pain according to AVE was 1. The MEPI was 83 points: 8 patients had excellent results, 11 good, 1 regular and 1 bad. Average DASH score was 24 points. Conclusion Treatment of humeral distal fractures with total elbow arthoplasty in patients older than 65 years old, may lead to a good option of treatment, but indications must be limited to patients with complex fractures, bad bone quality, with osteoporosis and low functional demands.

  7. Radial nerve palsy in mid/distal humeral fractures: is early exploration effective?

    Science.gov (United States)

    Keighley, Geffrey; Hermans, Deborah; Lawton, Vidya; Duckworth, David

    2018-03-01

    Radial nerve palsies are a common complication with displaced distal humeral fractures. This case series examines the outcomes of early operative exploration and decompression of the nerve with fracture fixation with the view that this provides a solid construct for optimisation of nerve recovery. A total of 10 consecutive patients with a displaced distal humeral fracture and an acute radial nerve palsy were treated by the senior author by open reduction and internal fixation of the distal humerus and exploration and decompression of the radial nerve. Motor function and sensation of the radial nerve was assessed in the post-operative period every 2 months or until full recovery of the radial nerve function had occurred. All patients (100%) had recovery of motor and sensation function of their upper limb in the radial nerve distribution over a 12-month period. Recovery times ranged between 4 and 32 weeks, with the median time to recovery occurring at 26 weeks and the average time to full recovery being 22.9 weeks. Wrist extension recovered by an average of 3 months (range 2-26 weeks) and then finger extension started to recover 2-6 weeks after this. Disability of the arm, shoulder and hand scores ranged from 0 to 11.8 at greater than 1 year post-operatively. Our study demonstrated that early operative exploration of the radial nerve when performing an open stabilization of displaced distal humeral fractures resulted in a 100% recovery of the radial nerve. © 2017 Royal Australasian College of Surgeons.

  8. Evaluation of an Image-Based Tool to Examine the Effect of Fracture Alignment and Joint Congruency on Outcomes after Wrist Fracture.

    Science.gov (United States)

    Lalone, Emily A; Grewal, Ruby; King, Graham W; MacDermid, Joy C

    2015-01-01

    Some mal-alignment of the wrist occurs in up to 71% of patients following a distal radius fracture. A multiple case study was used to provide proof of principle of an image-based technique to investigate the evolution and impact of post-traumatic joint changes at the distal radioulnar joint. Participants who had a unilateral distal radius fracture who previously participated in a prospective study were recruited from a single tertiary hand center. Long term follow-up measures of pain, disability, range of motion and radiographic alignment were obtained and compared to joint congruency measures. The inter-bone distance, a measure of joint congruency was quantified from reconstructed CT bone models of the distal radius and ulna and the clinical outcome was quantified using the patient rated wrist evaluation. In all four cases, acceptable post-reduction alignment and minimal pain/disability at 1-year suggested good clinical outcomes. However, 10 years following injury, 3 out of 4 patients had radiographic signs of degenerative changes occurring in their injured wrist (distal radioulnar joint/radio-carpal joint). Proximity maps displaying inter-bone distances showed asymmetrical congruency between wrists in these three patients. The 10-year PRWE (patient rated wrist evaluation) varied from 4 to 60, with 3 reporting minimal pain/disability and one experiencing high pain/disability. These illustrative cases demonstrate long-term joint damage post-fracture is common and occurs despite positive short-term clinical outcomes. Imaging and functional outcomes are not necessarily correlated. A novel congruency measure provides an indicator of the overall impact of joint mal-alignment that can be used to determine predictors of post-traumatic arthritis and is viable for clinical or large cohort studies.

  9. Ipsilateral vascularised ulnar transposition autograft for limb-sparing surgery of the distal radius in 2 dogs with osteosarcoma : clinical communication

    Directory of Open Access Journals (Sweden)

    G.S. Irvine-Smith

    2006-06-01

    Full Text Available Canine osteosarcoma is the most commonly diagnosed primary bone tumour in the dog, affecting mainly large and giant breed dogs with the predilection site being the metaphysis of long bones, specifically the distal radius, proximal humerus, distal femur and proximal tibia and fibula. Treatment options are either palliative or curative intent therapy, the latter limb amputation or limb-sparing surgery together with chemotherapy. This article describes the use of an ipsilateral vascularised ulnar transposition autograft as well as chemotherapy in 2 dogs with osteosarcoma of the distal radius. Both dogs showed minimal complications with the technique and both survived over 381 days following the surgery. Complications seen were loosening of the screws and osteomyelitis. The procedure was well tolerated with excellent limb use. This technique is indicated for use in cases with small tumour size that have not broken through the bone cortex.

  10. Trends in the United States in the treatment of distal radial fractures in the elderly.

    Science.gov (United States)

    Chung, Kevin C; Shauver, Melissa J; Birkmeyer, John D

    2009-08-01

    Traditionally, distal radial fractures in the elderly have been treated nonoperatively with casting. However, since the introduction of the volar locking plating system in 2000, there has been an interest in the use of more aggressive treatment methods. The purpose of the present study was to assess changing trends in the treatment of distal radial fractures in elderly patients in the United States. We evaluated a 5% sample of Medicare data from 1996 to 1997 and a 20% sample from 1998 to 2005. Information on four treatment methods (closed treatment, percutaneous pin fixation, internal fixation, and external fixation) was extracted from the dataset. Other available data were diagnosis, physician specialty, and patient age, sex, and race. We calculated frequencies and rates to compare the utilization of different treatments over time. Over the ten-year time period examined, the rate of internal fixation of distal radial fractures in the elderly increased fivefold, from 3% in 1996 to 16% in 2005. Closed treatment, however, remained the predominant method (used for 82% of the fractures in 1996 and 70% in 2005). Fractures in patients with an age of eighty-five years or more were significantly more likely to be treated in a closed fashion (p < 0.0001). There was a large variation among physician specialties with regard to the fixation methods that were used. Orthopaedic surgeons were significantly more likely to use closed treatment than hand surgeons were, whereas hand surgeons were significantly more likely to use internal fixation than orthopaedic surgeons were. Since 2000, although the majority of distal radial fractures are still treated nonoperatively, there has been an increase in the use of internal fixation and a concurrent decrease in the rate of closed treatment of distal radial fractures in the elderly in the United States.

  11. Distal phalanx fractures in horses: a survey of 274 horses with radiographic assessment of healing in 36 horses

    International Nuclear Information System (INIS)

    Honnas, C.M.; O'Brien, T.R.; Linford, R.L.

    1988-01-01

    The case records of 274 horses with fractures of the distal phalanx were reviewed. Fifty-two horses had bilateral forelimb fractures, for a total of 326 distal phalanx fractures. The fractures were classified into one of five previously described types, based on the radiographic anatomic configuration of the fracture. Solar margin fractures, which have been briefly described in other reports and previously classified as type V fractures, were identified in 132 horses. This type of fracture is distinct from other distal phalanx fractures. Due to the high incidence of solar margin fractures, these fractures were classified as a separate type (type VI). Follow-up radiographic examinations to assess fracture healing were available for 36 horses. Twenty-two horses with distal phalanx fractures (three type I, nine type II, two type III, one type IV, one type V, and six type VI) had radiographic evidence of complete bony union of the fracture at a mean of 11 months after injury. Eight horses with conplete type II fractures involving the articular surface had bony union of the body and solar margin, but not the subchondral bone at the articular surface, a mean of 11 months after injury. Six horses (four type II and two type IV) had little radiographic evidence of bony healing during the follow-up period. All fractures that eventually healed had evidence of progression toward bony union by 6 months after injury

  12. [TREATMENT OF PRONATION EXTERNAL ROTATION ANKLE FRACTURE COMBINED WITH SEPARATION OF DISTAL TIBIOFIBULAR SYNDESMOSIS].

    Science.gov (United States)

    Wu, Benwen; Ding, Zhenqi; Huang, Guofeng; Liu, Guojun; Cai, Zhemin; Ding, Luobin; Li, Xiang

    2016-09-08

    To evaluate the difference between using and not using syndesmotic screw to treat pronation external rotation (PER) ankle fracture combined with separation of distal tibiofibular syndesmosis. Between April 2011 and October 2014, 46 cases of PER ankle fracture combined with separation of distal tibiofibular syndesmosis were treated, and syndesmotic screw was used in 24 cases (fixation group) and syndesmotic screw was not used in 22 cases (non-fixation group). There was no significant difference in gender, age, weight, cause of injury, side, injury to operation time, and fracture type between 2 groups ( P >0.05). The time for full weight-bearing, fracture healing time, and complications were recorded after operation. Anteroposterior and lateral X-ray films were taken to measure the tibiofibular overlap (TBOL) and tibiofibular clear space (TBCS). Baird-Jackson score was used to evaluate functional recovery of the ankle. All incision healed by first intention without complications. The cases were followed up 13-18 months (mean, 15.2 months) in 2 groups. The time for full weight-bearing was 8-12 weeks (median, 11 weeks) in fixation group, which was significantly later than that in non-fixation group (range, 6-10 weeks; median, 8 weeks) ( Z =-5.049, P =0.000). X-ray examination showed reduction of separation of distal tibiofibular syndesmosis. All fractures healed. The fracture healing time was (13.83±1.37) weeks in fixation group, and was (13.91±1.31) weeks in non-fixation group, showing no significant difference ( t =-0.191, P =0.945). No separation of distal tibiofibular syndesmosis, delayed union, nonunion, loosening, or breakage of fixation devices was observed in 2 groups. There was no significant difference in TBOL, TBCS, Baird-Jackson score and the excellent and good rate between 2 groups ( P >0.05). If the medial, lateral, and posterior structures of the ankle could be repaired according to injury, no significant influence on functional outcome of ankle or

  13. Pre-bent elastic stable intramedullary nail fixation for distal radial shaft fractures in children.

    Science.gov (United States)

    Ge, Yi-hua; Wang, Zhi-gang; Cai, Hai-qing; Yang, Jie; Xu, Yun-lan; Li, Yu-chan; Zhang, Yu-chen; Chen, Bo-chang

    2010-08-01

    To investigate the functional and radiographic outcomes of pre-bent elastic stable intramedullary nail in treatment of distal radial shaft fractures in children. From January 2006 to December 2008, 18 children with distal radial shaft fracture were treated by close reduction and internal fixation with a pre-bent elastic stable intramedullary nail. The age range was from 5 years to 15 years, with an average of 9 years and 8 months. The minimum follow-up was 12 months. All fractures maintained good alignment postoperatively, and 94.4% (17/18) of the patients regained a full range of rotation of the forearm. One patient has limitation of rotation to less than 10°, this had improved by final follow-up. Complications included soft tissue irritation at the site of nail insertion in one patient and transient scar hypersensitivity in another. Fixation with a pre-bent elastic stable intramedullary nail is an effective, safe and convenient method for treating distal radial shaft fractures in children. © 2010 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.

  14. OUTCOME OF LOCKING PLATES IN DISTAL TIBIA FRACTURES TREATMENT

    Directory of Open Access Journals (Sweden)

    Lokesh

    2016-05-01

    Full Text Available INTRODUCTION Most of these fractures except intra-articular fractures are treated with interlocking nail. 1,2 These nails are a boon for these fractures. But as the fracture nears to the joint stability the fracture fixation will be compromised due to malreduction and alignment, it leads to increased chances of delayed and nonunion. 3 Locking anatomical plates are evaluated for anatomical and relative stability fixation. Since then most intra and near intra-articular fractures are fixed with these plates with minimally invasive percutaneous plate osteosynthesis method, these plates have given excellent result 4 . But again these plates have some disadvantages 5 . This study is done to see the outcome of locking plates in distal tibia fracture. METHODS This study is done in the Department of Orthopaedics, Bangalore Medical College, Bangalore. This study is done from 2013 to 2015. 30 patients who came to outpatient department were treated with locking plates. All patients above 16 years having distal third tibia fracture are included. All open fractures except type 1 and elderly above 60 years and pathological fractures are excluded in our study. All patients were followed up for initial 5 months, thereafter, once in 3 months, for clinical and radiological evaluation of union status, knee range of motion, ankle range of motion and other complications. Assessment of the patient with functional recovery was done with American Orthopaedic Foot and Ankle Surgery(AOFAS 6 minimum 5 months after injury. RESULTS Majority of the patients are from age group 18-29 years (50%. Average age group was 30 years. Majority of the patients were males 80.6% (25. All fractures were closed fractures except 2 cases which are type 1. There were 12 cases of AO type A, 8 patients were AO type B and 10 patients were type C. Majority of the patients had fracture due to road traffic accidents, 74%. All fractures were united by the end of 20 weeks. There was delayed union in

  15. DIAGNOSTICS AND TREATMENT OF DISTAL RADIOULNAR JOINT INJURIES

    Directory of Open Access Journals (Sweden)

    A. V. Skoroglyadov

    2010-01-01

    Full Text Available We present the experience of treatment of 169 patients with distal radioulnar joint injuries, operated in specialized hand surgery department of the Clinic of traumatology and orthopedics of Russian State Medical University on the base of Moscow city clinical hospital № 4. We have carried out the following operations: closed osteoclasia of the distal epimetaphys fractures, osteotomy of the radius with the external fixator application in 97 (57,4% patients, percutaneous 2 Kirschner wires fixation of the ulna head to the radius after reposition of dislocation - 38 (22,5% patients, lavsanoplasty of DRUJ ligaments - 12 (7,1%, fixation of the ulna head to the radius by pin - 7 (4,1%, open reposition of dislocation of the ulna head and K-wire fixation - 8 (4,8%, osteotomy of synostosis of forearm bones, W. Darrach and Sauve-Kapandji operations - 7 (4,1%. Complications were observed in 13 (7,7% cases. Postponed results (1 year after operation were studied in 110 patients. We got good results in 95 (86,4% cases, satisfactory - in 12 (10,9% cases, unsatisfactory - in 3 (2,7% cases.

  16. The percutaneous use of a pointed reduction clamp during intramedullary nailing of distal third tibial shaft fractures.

    Science.gov (United States)

    Forman, Jordanna M; Urruela, Adriana M; Egol, Kenneth A

    2011-12-01

    The purpose of this retrospective chart and radiographic review is to describe an effective reduction technique during intramedullary nailing of distal metaphyseal tibia fractures with the use of a pointed percutaneous clamp. Between 2007 and 2010, 100 patients who sustained 102 tibia fractures were definitively treated with an intramedullary nail at one of two medical centers. Diaphyseal fractures and injuries with an associated disruption of the distal tibiofibular joint were excluded from our study. A total of 27 patients with 27 distal metaphyseal tibia fractures (OTA types 42-A, 43-A, and 43-B) were included. All 27 patients underwent IM nailing of their fractures with anatomic reduction achieved using a percutaneously placed pointed reduction clamp prior to insertion of the IM implant. Fracture alignment and angular deformity was assessed using goniometric measurement functions on the PACS system (GE, Waukeshau, WI) obtained from preoperative and postoperative anteroposterior and lateral images for all subjects. Malalignment was defined as more than 5 degrees of angulation in any plane. Fourteen of the fractures were classified as OTA 42-A, 9 were OTA 43-A, and 4 were OTA 43-B. Analysis of post-closed reduction, preoperative anteroposterior radiographs revealed a mean of 7.9 degrees of coronal plane (range: 0.9 degrees-26 degrees) angulation. Post closed reduction preoperative lateral radiographs revealed a mean of 6.8 degrees sagittal plane (range: 0 degrees-24.6 degrees) angulation. Postoperative anteroposterior and lateral radiographs showed the distal segment returned to its anatomical alignment with a mean angulation of 0.5 degrees (range, 0 degrees-3.5 degrees) and 0.7 degrees (range, 0 degrees-4.2 degrees) of varus/ valgus and apex anterior/posterior angulation, respectively. These results showed an acceptable postopertative alignment in all 27 distal third fractures. No intra-operative or postoperative complications were noted in the study group. This

  17. Radiologic examination and measurement of the wrist and distal radio-ulnar joint

    International Nuclear Information System (INIS)

    Toernvall, A.H.; Ekenstam, F. af; Hagert, C.G.; Irstam, L.; Sahlgrenska Sjukhuset, Goeteborg; Uppsala Univ.

    1986-01-01

    Following fractures of the distal radius, a relatively high incidence of complications is caused by malalignment in the distal radio-ulnar (DRU) joint; recent anatomic and clinical investigations have shown a congruity of that joint to be of significant importance for restoring the function of the wrist. The radius forms a moderately arched bone, which moves around the ulna in pronation and supination. Biomechanically, the ulna may be regarded as the pillar around which the radius moves. In an anatomic investigation of 5 arm specimens, we have shown that the maximum cartilage contact in the DRU joint between the ulna head and the distal radius occurs in the neutral rotation position. A proposed routine examination method of the wrist and forearm includes a true antero-posterior and a lateral projection of the radius and the ulna, performed with the forearm and wrist in a neutral rotation, a neutral wrist deviation and with the elbow angled 90 degrees. Such an examination implies a standardized and reproducible method. In a radioanatomic investigation, a series of 50 healthy wrists and forearms were examined. A simple measuring technique is presented, applicable to the DRU joint and wrist favouring the ulna as the bone through which a reproducible long axis of the forearm/wrist may be drawn. It is suggested that the length of the radius should be judged relative to the ulna. Ulnar head inclination and radio-ulnar angle are new concepts, being major characteristics of the DRU joint. These angles of the right and left wrist were equal and no difference was found between the sexes. Minor alterations of the distal radius may be revealed when estimating these angles. (orig.)

  18. Fractures of the shafts of the radius and ulna

    International Nuclear Information System (INIS)

    Bender, C.E.; Campbell, D.C.

    1985-01-01

    Although the clinical presentation of fracture of the forearm bones is usually quite obvious, thorough radiologic examination of the radius and ulna and adjacent wrist and elbow joints is mandatory. Standard views of the forearm of the patient include the AP and lateral projections. The degree of shortening, angulation, rotation, and comminution should be noted. The selected films must be long enough to include the adjacent elbow and wrist joints

  19. Functional Results of Unstable (Type 2 Distal Clavicle Fractures Treated with Superior Anterior Locking Plate

    Directory of Open Access Journals (Sweden)

    Rajesh Govindasamy

    2017-11-01

    Full Text Available Background: The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higherrate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of thesefractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal endclavicle fractures treated with superior anterior locking plate.Methods: From June 2011 to August 2015 a retrospective study of12 male patients (mean age of 41.3 years 11 withunilateral and 1 with bilateral distal clavicle fractures treated with superior anterior locking plate was done. They wereevaluated at regular intervals with mean follow up of 14 months(12-18 months.Those with minimum one year followup were included in our study. All were evaluated for the functioning of the shoulder joint by both Oxford shoulder scoreand Quick DASH scores, rate of bone union, complications and earliest time for return to work.Results: All fractures union seen within 6-8 weeks (mean time: 7.1 weeks.All had good shoulder range of motion. Theaverage oxford shoulder and Quick DASH score were 46.2 and 6.5.There were no major complications in our studyviz. non-union, plate failure, secondary fracture. But one patient had superficial wound infection. All patients returned towork within 3 months of postoperative period.Conclusion: Displaced distal clavicle fractures treated with superior anterior locking plates achieved excellent resultsin terms of bony union with rarely any complications and demonstrate promising results with this novel technique.

  20. Comminuted Distal Radial Fracture with Large Rotated Palmar Medial Osteochondral Fragment in the Joint.

    Science.gov (United States)

    Gökkus, Kemal; Sagtas, Ergin; Kesgin, Engin; Aydin, Ahmet Turan

    2018-01-01

    Intra-articular distal radius fractures have long been massively discussed in the literature, but regarding to fractures that possess rotated volar medial fragment in the joint a few amount papers has been written. In this article, we would like to emphasize the significance of the rotated palmar medial (lunate facet) fragment. A 39-year-old man fell from a height of about 3 m and landed on his right outstretched hand; within 40 min, he arrived at our clinic presenting with a severe pain and swelling in his right wrist. Initial X-rays of the wrist revealed dorsal subluxation of the radiocarpal joint with dorsal comminution of the radial articular surface and fracture of the radial styloid process, with (nearly inverted) ~ 140-150° rotation of the palmar medial fragment. With an additional volar approach, the fragment reduced and stabilized with two K-wires and wrist immobilized in external fixator. The patient returned to daily activities without any discomfort and pain after the 1 year from the surgery. Overlooking of palmar rotated osteochondral fragment will cause deficiency to build proper pre-operative strategy to approach the reduction of the fragment. The incompetence of reduction will deteriorate the articular surface and lead to early osteoarthritis of the wrist. The surgeon should detect this fragment and should be familiar with volar approaches of the wrist. Above average surgical experience would be needed for successful reduction.

  1. Costs Associated With Single-Use and Conventional Sets for Distal Radius Plating.

    Science.gov (United States)

    Fugarino, Bryce; Fox, Mary Patricia; Terhoeve, Cristina; Pappas, Nicholas

    2017-11-01

    Volar plating of distal radius fractures is an increasingly common procedure. Presterilized, single-use volar plate fixation sets have been purported to increase operating room efficiency and decrease cost. The purpose of this study was to compare the actual cost of using a conventional set compared with the projected cost of using its single-use counterpart. We retrospectively analyzed 30 consecutive cases of volar plate fixation in which conventional instrument sets were used. Hardware and processing costs were calculated for the conventional sets and compared with the projected cost of using single-use sets. The mean total cost of hardware and processing for the conventional sets was $2,728, whereas the projected cost for the single-use sets was slightly higher at $2,868. Twenty-three of the 30 cases would have required additional screws not available in the single-use set. The cost of the additional screws needed to supplement the single-use set would have added an average of $282/case. Overall, the combined hardware and processing cost was lower for conventional sets in 25 of the 30 cases. Although the price of the single-use set is less than the mean charge for use of a conventional set, additional screws not available in the single-use set were required in 77% of cases and consequently rendered the conventional set cheaper in 83% of cases. Stocking the single-use sets with additional screws to reflect the most commonly used screw lengths could make these sets more cost effective in the future. Economic and decision analysis IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  2. CT evaluation of extensor tendon entrapment as a complication of a distal radial fracture in a child

    International Nuclear Information System (INIS)

    Frawley, Kieran J.; Anton, Christopher G.; Zbojniewicz, Andrew M.; Cornwall, Roger

    2011-01-01

    Extensor indicis proprius (EIP) entrapment is a rare complication of a distal radial fracture. We report an 11-year-old with limited flexion of her index finger 1 year after a distal radial fracture. The utility of cross-sectional imaging in the diagnosis and preoperative planning of this complication is presented. (orig.)

  3. Primary hyperparathyroidism associated with a giant cell tumor: One case in the distal radius.

    Science.gov (United States)

    Ouzaa, M R; Bennis, A; Iken, M; Abouzzahir, A; Boussouga, M; Jaafar, A

    2015-10-01

    Hyperparathyroidism can present itself as brown tumors (or osteolytic expansive lesions) that usually disappear after normalization of calcium and phosphate levels. It rarely occurs simultaneously with a giant cell tumor. The authors report one case of a localized form at the distal radius in a patient being followed for primary hyperparathyroidism. The diagnostic challenges related to the clinical and radiological similarities of these two pathological entities are discussed, as they can lead to delays in therapeutic management. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  4. Classification of fractures of the distal r[ius - Comparative evaluation of spiral CT images and X-rays

    International Nuclear Information System (INIS)

    Roehnert, W.; Nitzsche, H.; Franck, W.M.; Amlang, M.

    1998-01-01

    Within the framework of a prospective study 35 patients with fractures of the distal r[ius safely diagnosed to require surgery have been [ditionally scanned by spiral CT. For more exact diagnostic evaluation of the joint surfaces and the fractures, multiplane reconstructions have been m[e to enhance the information obtained from the primary, axial tomographic images. Two experts independently performed classification on the basis of the X-rays and the CT scans, applying the AO scheme and the method of Frykman. Classifications according to the AO scheme were found to agree for only 28.6 % of the patients, which means that 57.1 % of the fractures shown by the X-rays were more or less underassessed. Classification according to Frykman's method revealed fewer deviations and agreement in 51.4 % of the cases. Biplanar r[iography continues to be considered as the standard method for examination of distal r[ius fractures, but it is recommended to perform spiral CT scans for evaluation of more complex distal r[ius fractures because these may require different therapies according to fracture types. (orig./CB) [de

  5. Conservative treatment of intra-articular distal phalanx fractures in horses not used for racing.

    Science.gov (United States)

    Ohlsson, J; Jansson, N

    2005-04-01

    To determine the success rate and whether specific patient and treatment factors influenced the outcome after conservative treatment with a bar shoe with quarter clips of intra-articular fractures of the distal phalanx in horses not used for racing. Retrospective study. Thirty-two client-owned horses. Hospital records of horses that had been treated conservatively for intra-articular fractures of the distal phalanx at Skara Equine Hospital or Halland Animal Hospital in Sweden between 1995 and 2001 were reviewed. Racehorses in active training and horses affected with other musculoskeletal diseases were excluded from the study. Follow-up was performed by questionnaire and telephone inquires to the owners 1 to 7 years after injury. Twenty-two horses (69%) returned to their previous or expected level of use and did not wear their bar shoe when they were put back into training. There was no statistically significant correlation between outcome and patient or treatment variables, or bony union of the fracture. Conservative treatment of intra-articular fractures of the distal phalanx carries a fair prognosis for return to previous or expected level of use in horses not used for racing. Radiographic evidence of fracture healing and age of the patient do not seem to influence the prognosis. Horses not used for racing do not need to be shod with a bar shoe with quarter clips for the rest of their athletic career.

  6. Separate Vertical Wirings for the Extra-articular Fractures of the Distal Pole of the Patella

    OpenAIRE

    Kim, Young Mo; Yang, Jun Young; Kim, Kyung Cheon; Kang, Chan; Joo, Yong Bum; Lee, Woo Yong; Hwang, Jung Mo

    2011-01-01

    Purpose To evaluate the usefulness of separate vertical wirings for extra-articular fracture of distal pole of patella. Materials and Methods We have analyzed the clinical results of 18 cases that underwent separate vertical wirings for extra-articular fracture of distal pole of the patella from March 2005 to March 2010, by using the range of motion and Bostman score. Occurrence of complication was also evaluated. Additionally, by taking simple radiographs, the correlation between the postope...

  7. Comminuted distal femur closed fractures: a new application of the Ilizarov concept of compression-distraction.

    Science.gov (United States)

    El-Tantawy, Ahmad; Atef, Ashraf

    2015-04-01

    The treatment of intra-articular distal femur fractures with severe metaphyseal comminution is challenging. It is important to choose a technique that provides secure fixation, minimum tissue handling, and early ambulation. The aim of this work was to evaluate the outcomes of application of Ilizarov concept as an early definitive treatment of comminuted distal femur closed fractures. A total of 17 male patients (mean age 28.53±6.33 years) presented with comminuted distal femur fractures (with 10 type C2 and 7 type C3-2 fractures according to AO/ASIF system) were included in this prospective study. Initial fixation of the articular fragments was done by inter-fragmentary screws, percutaneously through a limited open approach, and stabilization was completed by Ilizarov fixator. The procedure included acute shortening, through the comminution, followed by gradual re-distraction to compensate the created shortening. Radiological and functional results were assessed according to ASAMI evaluation system. The mean amount of intra-operative shortening was 3.68±0.53 cm. The mean external fixation index was 37.24±2.53 days/cm. The mean follow-up period was 18.18±1.91 months. All fractures united primarily in an average 137.65±4.12 days, with no evident angular deformity or limb-length discrepancy. None of the cases required a second major procedure or bone graft. The functional results were excellent in three cases, good in 12, and fair in two patients. The Ilizarov concept of acute compression-distraction is a valuable alternative for the treatment of distal femur fractures with severe metaphyseal comminution.

  8. Limited open reduction is better for simple- distal tibial shaft fractures than minimally invasive plate osteosynthesis.

    Science.gov (United States)

    Li, Q; Zeng, B F; Luo, C F; Song, S; Zhang, C Q; Kong, W Q

    2014-07-24

    The aim of this study was to compare the effects and indications of minimally invasive plate osteosynthesis (MIPO) and limited open reduction (LOR) for managing distal tibial shaft fractures. A total of 79 cases of distal tibial shaft fractures were treated surgically in our trauma center. The 79 fracture cases were classified into type A, B, and C (C1) according to the Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification, with 28, 32, and 19 cases, respectively. Among the 79 fracture cases, 52 were closed fractures and 27 were open fractures (GUSTILO, I-II). After adequate preparation, 48 cases were treated with LOR and 31 cases were treated with MIPO. All cases were followed up for 12 to 18 months, with an average of 16.4 months. During the follow-up period, 76 fracture cases were healed in the first stage, whereas the 3 cases that developed non-union were treated by changing the fixation device and autografting. For types A, B, and some of C simple fractures (C1), LOR accelerated the fracture healing and lowered the non-union rate. One case suffered from regional soft tissue infection, which was controlled by wound dressing and intravenous antibiotics. Another case that developed local skin necrosis underwent local flap transplant. LOR promoted bone healing and lowered the non-union rate of several simple-distal tibial shaft fractures. Thereafter, the incidence of soft tissue complication was not significantly increased. However, for complex and comminuted fractures, MIPO was the preferred method for correcting bone alignment and protecting soft tissue, leading to functional recovery.

  9. MRI diagnosis of trapped periosteum following incomplete closed reduction of distal tibial Salter-Harris II fracture

    International Nuclear Information System (INIS)

    Raman, Subha; Wallace, E.C.

    2011-01-01

    Irreducible fracture of the distal tibial physis due to interposed soft tissue including periosteum is well documented in the orthopedic literature but is uncommon. This condition has been associated with subsequent growth disturbance and requires open reduction. There are very few prior reports of MRI depiction of soft tissue interposition and none of periosteal interposition in the distal tibial physis. This is a relatively common location of physeal injury and related growth disturbance. We present a case of periosteum trapped in the distal tibial physis, diagnosed on MRI, in a Salter-Harris II fracture and its management implications. (orig.)

  10. Occupational therapy and Colles' fractures

    OpenAIRE

    Christensen, O.M.; Kunov, A.; Hansen, F.F.; Christiansen, T.C.; Krasheninnikoff, M.

    2000-01-01

    In this randomized trial, we enrolled 30 patients treated for a distal radius Colles' type fracture. The fractures were reduced if necessary and fixed in a below-elbow plaster cast for 5 weeks. One group consisting of 14 patients received instructions for shoulder; elbow and finger exercise and the other group consisting of 16 patients had occupational therapy. At 5 weeks, 3 and 9 months we measured the functional scores. There were no statistically significant differences between the groups ...

  11. High-resolution-cone beam tomography analysis of bone microarchitecture in patients with acromegaly and radiological vertebral fractures.

    Science.gov (United States)

    Maffezzoni, Filippo; Maddalo, Michele; Frara, Stefano; Mezzone, Monica; Zorza, Ivan; Baruffaldi, Fabio; Doglietto, Francesco; Mazziotti, Gherardo; Maroldi, Roberto; Giustina, Andrea

    2016-11-01

    Vertebral fractures are an emerging complication of acromegaly but their prediction is still difficult occurring even in patients with normal bone mineral density. In this study we evaluated the ability of high-resolution cone-beam computed tomography to provide information on skeletal abnormalities associated with vertebral fractures in acromegaly. 40 patients (24 females, 16 males; median age 57 years, range 25-72) and 21 healthy volunteers (10 females, 11 males; median age 60 years, range: 25-68) were evaluated for trabecular (bone volume/trabecular volume ratio, mean trabecular separation, and mean trabecular thickness) and cortical (thickness and porosity) parameters at distal radius using a high-resolution cone-beam computed tomography system. All acromegaly patients were evaluated for morphometric vertebral fractures and for mineral bone density by dual-energy X-ray absorptiometry at lumbar spine, total hip, femoral neck, and distal radius. Acromegaly patients with vertebral fractures (15 cases) had significantly (p acromegaly patients did not have significant differences in bone density at either skeletal site. Patients with acromegaly showed lower bone volume/trabecular volume ratio (p = 0.003) and mean trabecular thickness (p acromegaly. High-resolution cone-beam computed tomography at the distal radius may be useful to evaluate and predict the effects of acromegaly on bone microstructure.

  12. Outcome analysis of retrograde nailing and less invasive stabilization system in distal femoral fractures: A retrospective analysis

    Directory of Open Access Journals (Sweden)

    Christian Hierholzer

    2011-01-01

    Full Text Available Background: Two major therapeutic principles can be employed for the treatment of distal femoral fractures: retrograde intramedullary (IM nailing (RN or less invasive stabilization on system (LISS. Both operative stabilizing systems follow the principle of biological osteosynthesis. IM nailing protects the soft-tissue envelope due to its minimally invasive approach and closed reduction techniques better than distal femoral locked plating. The purpose of this study was to evaluate and compare outcome of distal femur fracture stabilization using RN or LISS techniques. Materials and Methods: In a retrospective study from 2003 to 2008, we analyzed 115 patients with distal femur fracture who had been treated by retrograde IM nailing (59 patients or LISS plating (56 patients. In the two cohort groups, mean age was 54 years (17-89 years. Mechanism of injury was high energy impact in 57% (53% RN, 67% LISS and low-energy injury in 43% (47% RN, 33% LISS, respectively. Fractures were classified according to AO classification: there were 52 type A fractures (RN 31, LISS 21 and 63 type C fractures (RN 28, LISS 35; 32% (RN and 56% (LISS were open and 68% (RN and 44% (LISS were closed fractures, respectively. Functional and radiological outcome was assessed. Results: Clinical and radiographic evaluation demonstrated osseous healing within 6 months following RN and following LISS plating in over 90% of patients. However, no statistically significant differences were found for the parameters time to osseous healing, rate of nonunion, and postoperative complications. The following complications were treated: hematoma formation (one patient RN and three patients LISS, superficial infection (one patient RN and three patients LISS, deep infection (2 patients LISS. Additional secondary bone grafting for successful healing 3 months after the primary operation was required in four patients in the RN (7% of patients and six in the LISS group (10% of patients

  13. Reliability and validity of selected measures associated with increased fall risk in females over the age of 45 years with distal radius fracture - A pilot study.

    Science.gov (United States)

    Mehta, Saurabh P; MacDermid, Joy C; Richardson, Julie; MacIntyre, Norma J; Grewal, Ruby

    2015-01-01

    Clinical measurement. This study examined test-retest reliability and convergent/divergent construct validity of selected tests and measures that assess balance impairment, fear of falling (FOF), impaired physical activity (PA), and lower extremity muscle strength (LEMS) in females >45 years of age after the distal radius fracture (DRF) population. Twenty one female participants with DRF were assessed on two occasions. Timed Up and Go, Functional Reach, and One Leg Standing tests assessed balance impairment. Shortened Falls Efficacy Scale, Activity-specific Balance Confidence scale, and Fall Risk Perception Questionnaire assessed FOF. International Physical Activity Questionnaire and Rapid Assessment of Physical Activity were administered to assess PA level. Chair stand test and isometric muscle strength testing for hip and knee assessed LEMS. Intraclass correlation coefficients (ICC) examined the test-retest reliability of the measures. Pearson correlation coefficients (r) examined concurrent relationships between the measures. The results demonstrated fair to excellent test-retest reliability (ICC between 0.50 and 0.96) and low to moderate concordance between the measures (low if r ≤ 0.4; moderate if r = 0.4-0.7). The results provide preliminary estimates of test-retest reliability and convergent/divergent construct validity of selected measures associated with increased risk for falling in the females >45 years of age after DRF. Further research directions to advance knowledge regarding fall risk assessment in DRF population have been identified. Copyright © 2015 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  14. Complications associated with distraction plate fixation of wrist fractures.

    Science.gov (United States)

    Hanel, Douglas P; Ruhlman, Scott David; Katolik, Leo I; Allan, Christopher H

    2010-05-01

    This article discusses the major and minor complications of distal plating in the light of a cohort study carried out by the authors, who reviewed all patients undergoing bridge distraction plate fixation of distal radius fractures by three surgeons in a single level I trauma center. The article discusses the effectiveness and the complication rates associated with the technique. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  15. Radiologic examination and measurement of the wrist and distal radio-ulnar joint. New aspects

    Energy Technology Data Exchange (ETDEWEB)

    Toernvall, A.H.; Ekenstam, F. af; Hagert, C.G.; Irstam, L.

    Following fractures of the distal radius, a relatively high incidence of complications is caused by malalignment in the distal radio-ulnar (DRU) joint; recent anatomic and clinical investigations have shown a congruity of that joint to be of significant importance for restoring the function of the wrist. The radius forms a moderately arched bone, which moves around the ulna in pronation and supination. Biomechanically, the ulna may be regarded as the pillar around which the radius moves. In an anatomic investigation of 5 arm specimens, we have shown that the maximum cartilage contact in the DRU joint between the ulna head and the distal radius occurs in the neutral rotation position. A proposed routine examination method of the wrist and forearm includes a true antero-posterior and a lateral projection of the radius and the ulna, performed with the forearm and wrist in a neutral rotation, a neutral wrist deviation and with the elbow angled 90 degrees. Such an examination implies a standardized and reproducible method. In a radioanatomic investigation, a series of 50 healthy wrists and forearms were examined. A simple measuring technique is presented, applicable to the DRU joint and wrist favouring the ulna as the bone through which a reproducible long axis of the forearm/wrist may be drawn. It is suggested that the length of the radius should be judged relative to the ulna. Ulnar head inclination and radio-ulnar angle are new concepts, being major characteristics of the DRU joint. These angles of the right and left wrist were equal and no difference was found between the sexes. Minor alterations of the distal radius may be revealed when estimating these angles.

  16. Post-surgical rehabilitative approach to fragility fractures.

    Science.gov (United States)

    Gimigliano, F; Iolascon, G; Riccio, I; Frizzi, L; Gimigliano, R

    2013-10-01

    Osteoporosis is a skeletal disorder characterized by compromised bone strength predisposing to an increased risk of fracture. The most frequent sites of fragility fractures are the hip, the distal radius, the spine, the proximal humerus, and the ankle. In most cases, a surgical approach with subsequent rehabilitative treatment is required. The general aims of rehabilitation are to increase functioning and improve patients' activities, participation level, and quality of life.

  17. External fixation using locking plate in distal tibial fracture: a finite element analysis.

    Science.gov (United States)

    Zhang, Jingwei; Ebraheim, Nabil; Li, Ming; He, Xianfeng; Schwind, Joshua; Liu, Jiayong; Zhu, Limei

    2015-08-01

    External fixation of tibial fractures using a locking plate has been reported with favorable results in some selected patients. However, the stability of external plate fixation in this fracture pattern has not been previously demonstrated. We investigated the stability of external plate fixation with different plate-bone distances. In this study, the computational processing model of external fixation of a distal tibial metaphyseal fracture utilizing the contralateral femoral less invasive stabilization system plate was analyzed. The plate was placed on the anteromedial aspect of tibia with different plate-bone distances: 1, 10, 20, and 30 mm. Under axial load, the stiffness of construct in all groups was higher than intact tibia. Under axial load with an internal rotational force, the stiffness of construct with 1 and 10 mm plate-bone distances was similar to that of an intact tibia and the stiffness of the construct with 20 and 30 mm distances was lower than that of an intact tibia. Under axial load with an external rotational force, the stiffness of the construct in all groups was lower than that of an intact tibia. The maximum plate stresses were concentrated at the two most distal screws and were highest in the construct with the 10 mm plate-bone distance, and least in the construct with a 1 mm plate-bone distance. To guarantee a stable external plate fixation in distal tibial fracture, the plate-bone distance should be less than 30 mm.

  18. [Treatment of pediatric distal femur fractures by external fixator combined with limited internal fixation].

    Science.gov (United States)

    Wei, Sheng-wang; Shi, Zhan-ying; Hu, Ju-zheng; Wu, Hao

    2016-03-01

    To discuss the clinical effects of external fixator combined with limited internal fixation in the treatment of pediatric distal femur fractures. From January 2008 to June 2014, 17 children of distal femur fractures were treated by external fixator combined with limited internal fixation. There were 12 males and 5 females, aged from 6 to 13 years old with an average of 10.2 years, ranged in the course of disease from 1 h to 2 d. Preoperative diagnoses were confirmed by X-ray films in all children. There were 11 patients with supracondylar fracture , and 6 patients with intercondylar comminuted fracture. According to AO/ASIF classification, 9 fractures were type A1, 5 cases were type A2,and 3 cases were type C1. The intraoperative and postoperative complications, postoperative radiological examination, lower limbs length and motion of knee joints were observed. Knee joint function was assessed by KSS score. All the patients were followed up from 6 to 38 months with an average of 24.4 months. No nerve or blood vessel injury was found. One case complicated with the external fixation loosening, 2 cases with the infection of pin hole and 3 cases with the leg length discrepancy. Knee joint mobility and length measurement (compared with the contralateral), the average limited inflexion was 10 degrees (0 degrees to 20 degrees), the average limited straight was 4 degrees (0 degrees to 10), the average varus or valgus angle was 3 degrees (0 degrees to 5 degrees). KSS of the injured side was (96.4 +/- 5.0) points at final follow-up, 16 cases got excellent results and 1 good. All fractures obtained healing and no epiphyseal closed early was found. External fixator combined with limited internal fixation has advantages of simple operation, reliable fixation, early functional exercise in treating pediatric distal femurs fractures.

  19. [Effect factors analysis of knee function recovery after distal femoral fracture operation].

    Science.gov (United States)

    Bei, Chaoyong; Wang, Ruiying; Tang, Jicun; Li, Qiang

    2009-09-01

    To investigate the effect factors of knee function recovery after operation in distal femoral fractures. From January 2001 to May 2007, 92 cases of distal femoral fracture were treated. There were 50 males and 42 females, aged 20-77 years old (average 46.7 years old). Fracture was caused by traffic accident in 48 cases, by falling from height in 26 cases, by bruise in 12 cases and by tumble in 6 cases. According to Müller's Fracture classification, there were 29 cases of type A, 12 cases of type B and 51 cases of type C. According to American Society of Anesthesiologists (ASA) classification, there were 21 cases of grade I, 39 cases of grade II, 24 cases of grade III, and 8 cases of grade IV. The time from injury to operation was 4 hours to 24 days with an average of 7 days. Anatomical plate was used in 43 cases, retrograde interlocking intramedullary nail in 37 cases, and bone screws, bolts and internal fixation with Kirschner pins in 12 cases. After operation, the HSS knee function score was used to evaluate efficacy. Ten related factors were applied for statistical analysis, to knee function recovery after operation in distal femoral fractures, such as age, sex, preoperative ASA classification, injury to surgery time, fracture type, treatment, reduction quality, functional exercise after operation, whether or not CPM functional training and postoperative complications. Wound healed by first intention in 88 cases, infection occurred in 4 cases. All patients followed up 16-32 months with an average of 23.1 months. Clinical union of fracture was achieved within 3-7 months after operation. Extensor device adhesions and the scope of activities of fracture displacement in 6 cases, mild knee varus or valgus in 7 cases and implant loosening in 6 cases. According to HSS knee function score, the results were excellent in 52 cases, good in 15 cases, fair in 10 cases and poor in 15 cases with an excellent and good rate of 72.83%. Single factor analysis showed that age

  20. MRI findings of post-traumatic osteomyelitis of distal phalanx following neglected open fracture

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Eon; Lee, Ji Hee; Bae, Kung Eun; Kang, Min Jin; Kim, Jea Hyung; Cho, Woo Ho; Jeong, Myeong Ja; Kim, Soung Hee; Kim, Ji Young; Kim, Soo Hyun [Dept. of Radiology, Inje University Sanggye Paik Hospital, Seoul (Korea, Republic of)

    2017-07-15

    Careful radiologic examination of the osteolytic lesion is important for patients with fracture. Differential diagnosis includes osteonecrosis, neoplasm and infections. In this report, we presented MRI findings of post-traumatic osteomyelitis following neglected open fracture of 3rd distal phalanx with open wound. Early suspicion and imaging of wound or soft tissue inflammation around osteolytic lesion could be helpful for diagnosis of osteomyelitis.

  1. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.

    Science.gov (United States)

    Lujan, Trevor J; Henderson, Chris E; Madey, Steven M; Fitzpatrick, Dan C; Marsh, J Lawrence; Bottlang, Michael

    2010-03-01

    Locked plating constructs may be too stiff to reliably promote secondary bone healing. This study used a novel imaging technique to quantify periosteal callus formation of distal femur fractures stabilized with locking plates. It investigated the effects of cortex-to-plate distance, bridging span, and implant material on periosteal callus formation. Retrospective cohort study. One Level I and one Level II trauma center. Sixty-four consecutive patients with distal femur fractures (AO types 32A, 33A-C) stabilized with periarticular locking plates. Osteosynthesis using indirect reduction and bridge plating with periarticular locking plates. Periosteal callus size on lateral and anteroposterior radiographs. Callus size varied from 0 to 650 mm2. Deficient callus (20 mm2 or less) formed in 52%, 47%, and 37% of fractures at 6, 12, and 24 weeks postsurgery, respectively. Callus formation was asymmetric, whereby the medial cortex had on average 64% more callus (P=0.001) than the anterior or posterior cortices. A longer bridge span correlated minimally with an increased callus size at Week 6 (P=0.02), but no correlation was found at Weeks 12 and 24 postsurgery. Compared with stainless steel plates, titanium plates had 76%, 71%, and 56% more callus at Week 6 (P=0.04), Week 12 (P=0.03), and Week 24 (P=0.09), respectively. Stabilization of distal femur fractures with periarticular locking plates can cause inconsistent and asymmetric formation of periosteal callus. A larger bridge span only minimally improves callus formation. The more flexible titanium plates enhanced callus formation compared with stainless steel plates.

  2. Outcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia.

    Science.gov (United States)

    Gupta, Anil; Anjum, Rashid; Singh, Navdeep; Hackla, Shafiq

    2015-04-01

    Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteosynthesis for the fibula as well. A common complication associated with dual plating is an increased chance of soft tissue necrosis, infection, and in some cases resulting in an exposed implant. We conducted a prospective study to analyze the results of fractures of the distal in both leg bones managed by the MIPPO procedure for tibial fractures and a rush nail for fibular fractures. The study was conducted in a tertiary care hospital from November 2012 to May 2014, a total of 30 fractures in 30 patients (18 males, 12 females) with a mean age of 42.4 years (26-60 years) were treated in our institution in the aforesaid time period with MIPPO for tibia and rush nail for fibular fractures. All the cases were operated on by a single surgeon in emergency within 24 hours. The patients with skin blistering and compound fractures were excluded from this study. Rehabilitative measures were proceeded as per patient's pain profile, isometric and isotonic exercises were started on the first post-operative day, with full weight bearing at 10-12 weeks after assessing clinical and radiological union. Regular follow up of patients was done, radiographs were taken at the immediate post-operative period and at 3, 6, 12 and 24 weeks. All the patients were available for regular follow up. Radiological and clinical union proceeded normally in all the patients, no patients had signs of any deep infection, delayed union or nonunion, three patients had a superficial infection of the tibial incision that healed with a change in antibiotic. The use of dual plating for fixation of the lower tibia and fibula

  3. Bone morphometry and mineral contents of the distal part of the fractured third metacarpal bone in thoroughbred racehorses

    International Nuclear Information System (INIS)

    Yoshihara, T.; Oikawa, M.; Wada, R.; Hasegawa, M.; Kaneko, M.

    1990-01-01

    Most of the bone fractures in racehorses occur in the fore limb, especially in the metacarpal joint during the racing and training. The longitudinal fracture of the third metacarpal bone (Mc III) often occurs in the osteosclerotic and/or necrotic lesions in the distal part of the bone. To elucidate the endogenous factors of its fracture, soft radiograms of 4 fractured and 4 non-fractured control cases have been investigated morphometrically by a image analyzer. In addition, to analyze the quality of these bones, 20 elements of mineral contents in the crashed bones have been measured using a fluorescent X-ray analyzer. As the results, the osteosclerotic change was observed in both groups in the plantar side of the distal part of Mc III, however, no significant differences were found in the bone morphometry. No significant differences in the 19 elements of bone mineral were found except Fe. From these findings, the mechanism of the occurrence of the longitudinal fracture in the Mc III remains to be elucidated. In future, further work needs to be done with regard to the mechanical intensity and collagen disposition of the distal part of the Mc III

  4. Percutaneous locking plates for fractures of the distal tibia: our experience and a review of the literature.

    Science.gov (United States)

    Ahmad, Mudussar Abrar; Sivaraman, Alagappan; Zia, Ahmed; Rai, Amarjit; Patel, Amratlal D

    2012-02-01

    Distal tibial metaphyseal fractures pose many complexities. This study assessed the outcomes of distal tibial fractures treated with medial locking plates. Eighteen patients were selected based on the fracture pattern and classified using the AO classification and stabilized with an AO medial tibial locking plate. Time to fracture union, complications, and outcomes were assessed with the American Orthopedic Foot and Ankle Society Ankle score at 12 months. Sixteen of the 18 patients achieved fracture union, with 1 patient lost to follow-up. Twelve fractures united within 24 weeks, with an average union time of 23.1 weeks. Three delayed unions, two at 28 weeks and one at 56 weeks. The average time to union was 32 weeks in the smokers and 15.3 weeks in the nonsmokers. Five of the 18 patients (27%) developed complications. One superficial wound infection, and one chronic wound infection, resulting in nonunion at 56 weeks, requiring revision. Two patients required plate removal, one after sustaining an open fracture at the proximal end of the plate 6 months after surgery (postfracture union)and the other for painful hardware. One patient had implant failure of three proximal diaphyseal locking screws at the screwhead/neck junction, but successful fracture union. The average American Orthopedic Foot and Ankle Society ankle score was 88.8 overall, and 92.1 in fractures that united within 24 weeks. Distal tibial locking plates have high fracture union rates, minimum soft tissue complications, and good functional outcomes. The literature shows similar fracture union and complication rates in locking and nonlocking plates. Copyright © 2012 by Lippincott Williams & Wilkins

  5. Tratamento da pseudo-artrose do terço distal do rádio Treatment of nounion in the third distal of the radio

    Directory of Open Access Journals (Sweden)

    Marco Aurélio Sertório Grecco

    2005-01-01

    Full Text Available Os autores apresentaram um estudo prospectivo de quatro pacientes portadores de pseudo-artrose no terço distal do rádio. Dois eram do sexo feminino e dois do masculino, com idade média de 42,5 anos. O diagnóstico de pseudo-artrose foi realizado em média com 5,3 meses após o trauma. Um paciente apresentava, como antecedente mórbido pessoal, epilepsia e osteoporose, outros dois relataram tabagismo e obesidade e o quarto, fratura exposta. O tratamento consistiu de osteossíntese interna e enxertia com osso autógeno. Todos foram submetidos à avaliação clínica pré e pós-operatória quanto à força de preensão palmar e arco de movimentos do punho. Houve 100% de consolidação das fraturas do terço distal do rádio em pseudo-artrose e retorno dos pacientes às atividades profissionais.The authors presented a prospective study of four patients presenting pseudarthrosis at the distal third of the radius. Two patients were females and two were males, aged between 29 and 51 years with a mean age of 42.5 year old. The diagnosis of pseudarthrosis was provided within an average of 5.3 months after trauma. One patient presented as personal morbid history, epilepsy and osteoporosis, two patients were smokers and obese, and the fourth had an open fracture. The treatment consisted of internal osteosynthesis and autogenous bone graft. All patients were submitted to pre- and post operative clinical evaluation for palmar holding force and movement arch of the wrist. 100% of the radius distal-third fractures in pseudarthrosis have been united, with all patients returning to their respective professional activities.

  6. Complications of resection and reconstruction in giant cell tumour of distal end of radius - An analysis

    Directory of Open Access Journals (Sweden)

    Saraf S

    2005-01-01

    Full Text Available Background: The bulk of literature on the subject focuses on the resection of the tumor followed by reconstruction using autologous fibula, however, papers analyzing the failures of this procedure are scanty. The aim is to analyze the various factors responsible for the failures. Methods: Study included 42 patients of aggressive GCT of distal radius, resected and reconstructed using nonvascularised autologous fibula. Host graft junction was fixed using screws (6, intramedullary nail (21 and plate (15. The minimum follow-up was 2 years or till a complication occurred requiring second surgery. Result: The major complications were recurrence in 6 cases (spillage of tumor tissue in 3, poor biopsy site 2, recurrence along the nail tract one case; failure of host graft union in 8 cases due to inadequate contact at host graft junction, poor implant selection, inadequate immobilization and infection; significant instability at wrist in 6 cases due to poor stabilization at carpo fibular junction in addition to inherent instability due to poor congruity between fibulocarpal articulations. Conclusion: Reconstruction of distal end of radius using auto fibula has much higher complication rates than usually believed. A meticulous planning and its execution is must to minimize the problems. Use of dynamic plate for host graft junction and fixation of fibular head to adjacent ulna/carpal bones improves the results.

  7. Combined Volar and Dorsal Approach for Fixation of Comminuted Intra-Articular Distal Radial Fractures.

    Science.gov (United States)

    Medlock, G; Smith, M; Johnstone, A J

    2018-07-01

    Purpose  Multifragmentary intra-articular fractures displaced in multiple planes are a challenge. We use a reproducible technique of fracture and articular reduction using an initial volar approach targeting reduction in the volar lunate facet first with plate and unicortical locking screws. This creates a template for reduction in dorsal fragments through a dorsal approach. Our study investigated the radiological, clinical, and functional outcomes of patients treated with this technique. Materials and Methods  We reviewed the postoperative radiographs and notes of 18 patients that had this method of fixation between the years 2008 and 2015, the mean age being 43. These patients were reviewed functionally on average 2 years and 3 months following their definitive operation. Results  Normal alignment and length to the distal radius were restored with on average a 0.6 mm articular step. The average range of motion was 64% and preservation of grip strength was 71% compared with the uninjured wrist. Functional assessment averages were 29 for both the quick Disabilities of the Arm, Shoulder and Hand (DASH) and for Patient Rated Wrist Evaluation. The modified system of Green and O'Brien had results of good in 10, fair in 7, and poor in 1. With respect to the Gartland and Werley system, three patients had an excellent result, four had a good result, six had a fair result, and five had a poor result. The mean arthritic grading was 1 (grading 0-3) according to Knirk and Jupiter. Conclusion  This reproducible technique provides an option for these devastating fractures providing a functioning wrist with all of the patients returning to their original form of employment.

  8. Uncemented three-dimensional-printed prosthetic replacement for giant cell tumor of distal radius: a new design of prosthesis and surgical techniques

    Directory of Open Access Journals (Sweden)

    Lu MX

    2018-02-01

    Full Text Available Minxun Lu,* Li Min,* Cong Xiao, Yongjiang Li, Yi Luo, Yong Zhou, Wenli Zhang, Chongqi Tu Department of Orthopedics, West China Hospital, Sichuan University, Chengdu, Sichuan, People’s Republic of China *These authors contributed equally to this work Introduction: Currently, it is challenging to treat giant cell tumor (GCT of distal radius. For Campanacci grade III or recurrent GCTs, en bloc resection has been accepted as a better treatment option. Although numerous methods are available for reconstruction, all of them have some limitations in joint function and complications. In this study, our aims were to treat the GCT of distal radius with uncemented three-dimensional (3D-printed prosthesis and to present and evaluate the surgical techniques and short-term outcomes. Methods: Between September 2015 and March 2017, 11 patients with distal radius GCTs were treated with personalized uncemented 3D-printed prosthesis. The preoperative/postoperative pain, range of motion, and grip strengths of all patients were evaluated. Oncological results, complications, and degenerative changes in the wrist joint were evaluated. Functional outcomes were assessed according to the disabilities of the arm, shoulder, and hand (DASH questionnaire and Mayo wrist scoring systems. Results: The average follow-up was 14.45 months (range, 8–18 months. There was a significant decrease in the mean postoperative visual analog scale score (2.33 compared with the preoperative score (5.22; p<0.001. The mean DASH score and Mayo wrist score of the wrist joint function were 18.7 and 72, respectively. There was no local recurrence or lung metastasis. No complication associated with prosthesis was observed, including aseptic loosening, subluxation, and breakage. Joint space narrowing, or disuse osteoporosis, was also not found in all cases. Conclusion: En bloc resection and reconstruction with a personalized uncemented 3D-printed prosthesis can be alternative options to

  9. Fractures of the distal limb occuring under effective diagnostic anaethesia during equine lameness examination

    OpenAIRE

    Plückhahn, Nina

    2011-01-01

    Fractures of the distal limb occuring during present effect of diagnostic nerve blocks respective intraarticular anesthesia represent rare but severe complications in equine lameness examinations. Due to very poor prognosis most cases in this study resulted in euthanisation of the horse. Several reasons can be claimed to cause fractures. As for the above mentioned fact that total loss of the animal is common due to severity of the fracture, the most important reason is represented by undet...

  10. Longitudinal recovery following distal radial fractures managed with volar plate fixation.

    Science.gov (United States)

    Stinton, S B; Graham, P L; Moloney, N A; Maclachlan, L R; Edgar, D W; Pappas, E

    2017-12-01

    To synthesise the literature and perform a meta-analysis detailing the longitudinal recovery in the first two years following a distal radius fracture (DRF) managed with volar plate fixation. Three databases were searched to identify relevant articles. Following eligibility screening and quality assessment, data were extracted and outcomes were assimilated at the post-operative time points of interest. A state-of-the-art longitudinal mixed-effects meta-analysis model was employed to analyse the data. The search identified 5698 articles, of which 46 study reports met the selection criteria. High levels of disability and impairment were reported in the immediate post-operative period with subsequently a rapid initial improvement followed by more gradual improvement for up to one year. The results highlight that the period associated with the greatest physical recovery is in the first three months and suggest that the endpoint of treatment outcomes is best measured at one year post-surgery. Clinically meaningful improvements in outcomes can be expected for 12 months, after which progress plateaus and reaches normal values. This paper adopted a novel approach to meta-analyses in that the research question was of a longitudinal nature, which required a unique method of statistical analysis. Cite this article: Bone Joint J 2017;99-B:1665-76. ©2017 The British Editorial Society of Bone & Joint Surgery.

  11. [Application of three-dimensional printing technology in treatment of internal or external ankle distal avulsed fracture].

    Science.gov (United States)

    Shi, Weixiang; Luo, Xiaozhong; Wu, Gang; Ding, Yong; Zhou, Xin

    2018-02-01

    To explore the effectiveness and advantage of three-dimensional (3D) printing technology in treatment of internal or external ankle distal avulsed fracture. Between January 2015 and January 2017, 20 patients with distal avulsed fracture of internal or external ankle were treated with the 3D guidance of shape-blocking steel plate fixation (group A), and 18 patients were treated with traditional plaster external fixation (group B). There was no significant difference in gender, age, injury cause, disease duration, fracture side, and fracture type between 2 groups ( P >0.05). Recording the fracture healing rate, fracture healing time, the time of starting to ankle functional exercise, residual ankle pain, and evaluating ankle function recovery of both groups by the American Orthopaedic Foot and Ankle Society (AOFAS) score. All patients were followed up 8-24 months, with an average of 15.5 months. In group A: all incisions healed by first intention, the time of starting to ankle functional exercise was (14±3) days, fracture healing rate was 100%, and the fracture healing time was (10.15±2.00) weeks. At 6 months, the AOFAS score was 90.35±4.65. Among them, 13 patients were excellent and 7 patients were good. All patients had no post-operative incision infection, residual ankle pain, or dysfunction during the follow-up. In group B: the time of starting to ankle functional exercise was (40±10) days, the fracture healing rate was 94.44%, and the fracture healing time was (13.83±7.49) weeks. At 6 months, the AOFAS score was 79.28±34.28. Among them, 15 patients were good, 2 patients were medium, and 1 patient was poor. During the follow-up, 3 patients (16.67%) had pain of ankle joint with different degrees. There were significant differences in the postoperative fracture healing rate, fracture healing time, the time of starting to ankle functional exercise, and postoperative AOFAS score between 2 groups ( P internal or external ankle distal avulsed fracture is simple

  12. Distal tibial pilon fractures (AO/OTA type B, and C) treated with the external skeletal and minimal internal fixation method.

    Science.gov (United States)

    Milenković, Sasa; Mitković, Milorad; Micić, Ivan; Mladenović, Desimir; Najman, Stevo; Trajanović, Miroslav; Manić, Miodrag; Mitković, Milan

    2013-09-01

    Distal tibial pilon fractures include extra-articular fractures of the tibial metaphysis and the more severe intra-articular tibial pilon fractures. There is no universal method for treating distal tibial pilon fractures. These fractures are treated by means of open reduction, internal fixation (ORIF) and external skeletal fixation. The high rate of soft-tissue complications associated with primary ORIF of pilon fractures led to the use of external skeletal fixation, with limited internal fixation as an alternative technique for definitive management. The aim of this study was to estimate efficacy of distal tibial pilon fratures treatment using the external skeletal and minimal internal fixation method. We presented a series of 31 operated patients with tibial pilon fractures. The patients were operated on using the method of external skeletal fixation with a minimal internal fixation. According to the AO/OTA classification, 17 patients had type B fracture and 14 patients type C fractures. The rigid external skeletal fixation was transformed into a dynamic external skeletal fixation 6 weeks post-surgery. This retrospective study involved 31 patients with tibial pilon fractures, average age 41.81 (from 21 to 60) years. The average follow-up was 21.86 (from 12 to 48) months. The percentage of union was 90.32%, nonunion 3.22% and malunion 6.45%. The mean to fracture union was 14 (range 12-20) weeks. There were 4 (12.19%) infections around the pins of the external skeletal fixator and one (3.22%) deep infections. The ankle joint arthrosis as a late complication appeared in 4 (12.90%) patients. All arthroses appeared in patients who had type C fractures. The final functional results based on the AOFAS score were excellent in 51.61%, good in 32.25%, average in 12.90% and bad in 3.22% of the patients. External skeletal fixation and minimal internal fixation of distal tibial pilon fractures is a good method for treating all types of inta-articular pilon fractures. In

  13. Dual-energy X-ray absorptiometry in the lumbar spine, proximal femur and distal radius in children

    International Nuclear Information System (INIS)

    Tsukahara, H.; Sudo, M.; Umezaki, M.; Hiraoka, M.; Yamamoto, K.; Ishii, Y.; Haruki, S.

    1992-01-01

    Dual-energy X-ray absorptiometry was used to measure bone mineral density (BMD) in the lumbar spine, proximal femur and distal radius in 48 Japanese children aged 3-18 years. In the normal children (n=32), BMD increased with age in all locations, with a nearly twofold increase from preschool age to adolescence. Most of the children with chronic diseases known to affect bone metabolism (e.g., steroid osteoporosis) (n=16) had low BMD in every region, indicating that these disease states probably affect multiple sites of the skeleton in children. (orig.)

  14. [Close reduction combined with minimally invasive percutaneous plate osteosynthesis for proximal and distal tibial fractures: a report of 56 patients].

    Science.gov (United States)

    Liu, Yin-Wen; Kuang, Yong; Gu, Xin-Feng; Zheng, Yu-Xin; Li, Zhi-Qiang; Wei, Xiao-En; Zhang, Ming-Cai; Zhan, Hong-Sheng; Shi, Yin-yu

    2013-03-01

    To evaluate the clinical effects of close reduction combined with minimally invasive percutanous plate osteosynthesis (MIPPO) for proximal and distal tibial fractures. From March 2007 to December 2010, 56 patients with proximal and distal tibial fractures were treated with close reduction combined with MIPPO technique. There were 39 males and 17 females,aged from 22 to 67 years with an average of 41.3 years. Left fracture was in 25 cases and right fracture was in 31 cases; proximal tibial fracture was in 15 cases and distal tibial fractures was in 41 cases; 34 cases caused by fall down and 22 cases caused by road accident. The mean time from injury to operation was 1.7 d. Clinical manifestation included pain, swelling of leg with limitation of activity. According to the standard of Johner-Wruhs, clinical effects were evaluated. The mean operative time was 46 min in 56 patients. All fractures obtained satisfactory reduction and the location of plate was good. Incisions healed with one-stage and no superficial or deep infection was found. All the patients were followed up from 8 to 23 months with an average of 14.2 months. Only one fracture complication with delayed union,and after auto grafting with ilium bone,the fracture got union. Other 55 cases obtained bone healing in 15 to 20 weeks after operation and no internal fixation failure was found. The time of walking was 4-6 months after operation,without limping at 7 months after operation. Both lower extremities were symmetrical and the function of knee and ankle got complete recovery. According to the criteria of Johner-Wruhs score,46 cases obtained excellent results,9 good and 2 fair. Treatment of proximal and distal tibial fractures with close reduction and MIPPO technique can not only preserve soft tissue,simplify operative procedure and decrease wound, but also can obtain rigid internal fixation and guarantee early function exercises of knee and ankle joints. The method has the advantages of less soft tissue

  15. Distal tibial fractures are a poorly recognised complication with fibula free flaps.

    Science.gov (United States)

    Durst, A; Clibbon, J; Davis, B

    2015-09-01

    The fibula free flap is ideal for complex jaw reconstructions, with low reported donor and flap morbidity. We discuss a distal tibial stress fracture two months following a vascularised fibula free flap procedure. Despite being an unrecognised complication, a literature review produced 13 previous cases; only two were reported in the reconstructive surgery literature, with the most recent claiming to be the first. The majority of these studies treated this fracture non-operatively; none reported their patient follow-up. Each case presented with ipsilateral leg pain, which has been cited as an early donor site morbidity in as many as 40% of fibula free flap cases. It is known that the fibula absorbs at least 15% of leg load on weight bearing. Studies have shown severe valgus deformities in up to 25% of patients with fibulectomies. We treated our patient operatively, first correcting his worsening valgus deformity with an external fixator, then reinforcing his healed fracture with a long distal tibial plate. We believe that this complication is underreported, unexpected and not mentioned during the consenting process. By highlighting the management of our case and the literature, we aim to increase awareness (and thus further reporting and appropriate management) of this debilitating complication.

  16. Assessment of Outcomes of Treatment of Fractures of Distal Femur with a Locking Plate Taking into Account Factors Influencing the Result.

    Science.gov (United States)

    Pakuła, Grzegorz; Kwiatkowski, Krzysztof; Kuczmera, Piotr; Fudalej, Piotr

    2015-10-01

    The aim of this paper is to evaluate the results of treatment of distal femoral fractures (DFF) fixed with locking plates and analysis of factors that influence the final outcome. The patients were treated at the Department of Traumatology and Orthopedics, Military Medical Institute in Warsaw, and the Department of Orthopedics and Traumatology, 4th Military Research Hospital in Wroclaw. We analysed 39 patients with 42 fractures of the distal femur. Treatment results were analysed using the KOOS and KSS scales. Factors influencing the outcome were also investigated. Statistical analysis was performed using STATISTICA v. 10. Mean KOOS scores indicate a predominance of poor outcomes, while mean KSS scores indicate good outcomes. Treatment outcomes were significantly influenced by pain and limited mobility. 1. Subjective evaluation of treatment of fractures of the distal femur using the KOOS scale per form edworse than a clinical evaluation using the KSS. 2. Post-operative management should emphasise pain relief and restoration of the performance of the treated lower limb to ensure good mobility without crutches. 3. Despite the use of modern operational methods of fracture fixation, treatment of distal femur fractures is still a challenge.

  17. Limited arthrodesis of the wrist for treatment of giant cell tumor of the distal radius.

    Science.gov (United States)

    Flouzat-Lachaniette, Charles-Henri; Babinet, Antoine; Kahwaji, Antoine; Anract, Philippe; Biau, David-Jean

    2013-08-01

    To present the functional results of a technique of radiocarpal arthrodesis and reconstruction with a structural nonvascularized autologous bone graft after en bloc resection of giant cell tumors of the distal radius. A total of 13 patients with a mean age of 37 years with aggressive giant cell tumor (Campanacci grade III) of distal radius were managed with en bloc resection and reconstruction with a structural nonvascularized bone graft. The primary outcome measure was the disability evaluated by the Musculoskeletal Tumor Society rating score of limb salvage. Secondary outcomes included survival of the reconstruction measured from the date of the operation to revision procedure for any reason (mechanical, infectious, or oncologic). Other outcomes included active wrist motion and ability to resume work. Mean follow-up period was 6 years (range, 2-14 y). The median arc of motion at the midcarpal joint was 40°, median wrist flexion was 20°, and median extension was 10°. The median Musculoskeletal Tumor Society score based on the analysis of factors pertinent to the patient as a whole (pain, functional activities, and emotional acceptance) and specific to the upper limb (positioning of the hand, manual dexterity, and lifting ability) was 86%. Five patients underwent a second surgical procedure. The cumulative probability of reoperation for mechanical reason was 31% at similar follow-up times at 2, 5, and 10 years. This technique provided a stable wrist and partially restored wrist motion with limited pain. However, further surgical procedures may be necessary to reach this goal. Therapeutic IV. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  18. Advantages of the Ilizarov external fixation in the management of intra-articular fractures of the distal tibia

    Directory of Open Access Journals (Sweden)

    Kaspiris Angelos

    2009-09-01

    Full Text Available Abstract Background Treatment of distal tibial intra-articular fractures is challenging due to the difficulties in achieving anatomical reduction of the articular surface and the instability which may occur due to ligamentous and soft tissue injury. The purpose of this study is to present an algorithm in the application of external fixation in the management of intra-articular fractures of the distal tibia either from axial compression or from torsional forces. Materials and methods Thirty two patients with intra-articular fractures of the distal tibia have been studied. Based on the mechanism of injury they were divided into two groups. Group I includes 17 fractures due to axial compression and group II 15 fractures due to torsional force. An Ilizarov external fixation was used in 15 patients (11 of group I and 4 of group II. In 17 cases (6 of group I and 11 of group II a unilateral hinged external fixator was used. In 7 out of 17 fractures of group I an additional fixation of the fibula was performed. Results All fractures were healed. The mean time of removal of the external fixator was 11 weeks for group I and 10 weeks for group II. In group I, 5 patients had radiological osteoarthritic lesions (grade III and IV but only 2 were symptomatic. Delayed union occurred in 3 patients of group I with fixed fibula. Other complications included one patient of group II with subluxation of the ankle joint after removal of the hinged external fixator, in 2 patients reduction found to be insufficient during the postoperative follow up and were revised and 6 patients had a residual pain. The range of ankle joint motion was larger in group II. Conclusion Intra-articular fractures of the distal tibia due to axial compression are usually complicated with cartilaginous problems and are requiring anatomical reduction of the articular surface. Fractures due to torsional forces are complicated with ankle instability and reduction should be augmented with ligament

  19. Advantages of the Ilizarov external fixation in the management of intra-articular fractures of the distal tibia

    Science.gov (United States)

    Vasiliadis, Elias S; Grivas, Theodoros B; Psarakis, Spyridon A; Papavasileiou, Evangelos; Kaspiris, Angelos; Triantafyllopoulos, Georgios

    2009-01-01

    Background Treatment of distal tibial intra-articular fractures is challenging due to the difficulties in achieving anatomical reduction of the articular surface and the instability which may occur due to ligamentous and soft tissue injury. The purpose of this study is to present an algorithm in the application of external fixation in the management of intra-articular fractures of the distal tibia either from axial compression or from torsional forces. Materials and methods Thirty two patients with intra-articular fractures of the distal tibia have been studied. Based on the mechanism of injury they were divided into two groups. Group I includes 17 fractures due to axial compression and group II 15 fractures due to torsional force. An Ilizarov external fixation was used in 15 patients (11 of group I and 4 of group II). In 17 cases (6 of group I and 11 of group II) a unilateral hinged external fixator was used. In 7 out of 17 fractures of group I an additional fixation of the fibula was performed. Results All fractures were healed. The mean time of removal of the external fixator was 11 weeks for group I and 10 weeks for group II. In group I, 5 patients had radiological osteoarthritic lesions (grade III and IV) but only 2 were symptomatic. Delayed union occurred in 3 patients of group I with fixed fibula. Other complications included one patient of group II with subluxation of the ankle joint after removal of the hinged external fixator, in 2 patients reduction found to be insufficient during the postoperative follow up and were revised and 6 patients had a residual pain. The range of ankle joint motion was larger in group II. Conclusion Intra-articular fractures of the distal tibia due to axial compression are usually complicated with cartilaginous problems and are requiring anatomical reduction of the articular surface. Fractures due to torsional forces are complicated with ankle instability and reduction should be augmented with ligament repair, in order to

  20. Comparison of Internal Fixations for Distal Clavicular Fractures Based on Loading Tests and Finite Element Analyses

    Directory of Open Access Journals (Sweden)

    Rina Sakai

    2014-01-01

    Full Text Available It is difficult to apply strong and stable internal fixation to a fracture of the distal end of the clavicle because it is unstable, the distal clavicle fragment is small, and the fractured region is near the acromioclavicular joint. In this study, to identify a superior internal fixation method for unstable distal clavicular fracture, we compared three types of internal fixation (tension band wiring, scorpion, and LCP clavicle hook plate. Firstly, loading tests were performed, in which fixations were evaluated using bending stiffness and torsional stiffness as indices, followed by finite element analysis to evaluate fixability using the stress and strain as indices. The bending and torsional stiffness were significantly higher in the artificial clavicles fixed with the two types of plate than in that fixed by tension band wiring (P<0.05. No marked stress concentration on the clavicle was noted in the scorpion because the arm plate did not interfere with the acromioclavicular joint, suggesting that favorable shoulder joint function can be achieved. The stability of fixation with the LCP clavicle hook plate and the scorpion was similar, and plate fixations were stronger than fixation by tension band wiring.

  1. Distal tibial pilon fractures (AO/OTA type B, and C treated with the external skeletal and minimal internal fixation method

    Directory of Open Access Journals (Sweden)

    Milenković Saša

    2013-01-01

    Full Text Available Background/Aim. Distal tibial pilon fractures include extra-articular fractures of the tibial metaphysis and the more severe intra-articular tibial pilon fractures. There is no universal method for treating distal tibial pilon fractures. These fractures are treated by means of open reduction, internal fixation (ORIF and external skeletal fixation. The high rate of soft-tissue complications associated with primary ORIF of pilon fractures led to the use of external skeletal fixation, with limited internal fixation as an alternative technique for definitive management. The aim of this study was to estimate efficacy of distal tibial pilon fratures treatment using the external skeletal and minimal internal fixation method. Methods. We presented a series of 31 operated patients with tibial pilon fractures. The patients were operated on using the method of external skeletal fixation with a minimal internal fixation. According to the AO/OTA classification, 17 patients had type B fracture and 14 patients type C fractures. The rigid external skeletal fixation was transformed into a dynamic external skeletal fixation 6 weeks post-surgery. Results. This retrospective study involved 31 patients with tibial pilon fractures, average age 41.81 (from 21 to 60 years. The average follow-up was 21.86 (from 12 to 48 months. The percentage of union was 90.32%, nonunion 3.22% and malunion 6.45%. The mean to fracture union was 14 (range 12-20 weeks. There were 4 (12.19% infections around the pins of the external skeletal fixator and one (3.22% deep infections. The ankle joint arthrosis as a late complication appeared in 4 (12.90% patients. All arthroses appeared in patients who had type C fractures. The final functional results based on the AOFAS score were excellent in 51.61%, good in 32.25%, average in 12.90% and bad in 3.22% of the patients. Conclusion. External skeletal fixation and minimal internal fixation of distal tibial pilon fractures is a good method for

  2. [True/Flex intramedullary nailing for forearm shaft fractures. Long-term results].

    Science.gov (United States)

    Trlica, J; Počepcov, I; Kočí, J; Frank, M; Holeček, T; Dědek, T

    2012-01-01

    Presentation of technical experience and the clinical and functional results of intramedullary fixation of forearm shaft fractures. Between January 1994 and December 2009, a total of 96 patients with 144 radial and/or ulnar fractures (ulna, 33; radius,15; both, 48) were treated by nailing (True/Flex®). According to the AO classification there were 22-A, 22-B and 22-C type fractures in 39 (41%), 44 (46%) and 13 (13%).cases, respectively. Of these, 82 (85%) were closed (types: 0, 48; I, 33; II, 1) and 14 (15%) were open (types: I, 13; II, 1; III, 0) fractures. Seventy-eight patients (81%) were followed up and their functional outcomes were evaluated according to the criteria of Anderson et al. The average interval between the operation and final follow-up was 28 months (15 to 96 months) The average time to surgery was 2.2 days (0 to 25 days). Early complications were recorded in 4% of the patients (1x bursitis olecrani; 1x end cup replacement; 1x bending of nails) and late complications in 15% (5x non-union; 2x delay union; 4x bursitis olecrani; 1x ruptured tendon). Bone healing was achieved in 95% of the cases and took on average 16 weeks (7 to 34 weeks). No infection, refracture or synostosis occurred. Primary loss of reduction was recorded in four cases due to distraction in one, bent nails in two and a wrong size of the implant in one; secondary loss of reduction was found in three cases, with two cases of radius shortening and one 10°malrotation. No primary malrotation was recorded, but secondary loss of alignment was seen in the distal part of the radius and the proximal part of the ulna. Functional results according to the Anderson criteria were excellent and good in 87% of the cases. Intramedullary mailing provides good stability to mid- and distal-third shaft fractures of the ulna and mid- and proximalthird shaft fractures of the radius, particularly in AO type A and type B fractures. The technical aspects of the method are analysed in detail in this paper

  3. Retrospective analysis of extra-articular distal humerus shaft fractures treated with the use of pre-contoured lateral column metaphyseal LCP by triceps-sparing posterolateral approach

    Directory of Open Access Journals (Sweden)

    Yatinder Kharbanda

    2016-11-01

    Full Text Available Abstract Management of extra-articular distal humerus fractures presents a challenge to the treating surgeon due to the complex anatomy of the distal part of the humerus and complicated fracture morphology. Although surgical treatment has shown to provide a more stable reduction and alignment and predictable return to function, it has been associated with complications like iatrogenic radial nerve palsy, infection, non-union and Implant failure. We in the present series retrospectively analysed 20 patients with extra-articular distal humerus shaft fractures surgically treated using the extra-articular distal humeral locking plate approached by the triceps-sparing posterolateral approach. The outcome was assessed using the DASH score, range of motion at the elbow and the time to union. The mean time to radiographic fracture union was 12 weeks.

  4. Retrospective analysis of extra-articular distal humerus shaft fractures treated with the use of pre-contoured lateral column metaphyseal LCP by triceps-sparing posterolateral approach.

    Science.gov (United States)

    Kharbanda, Yatinder; Tanwar, Yashwant Singh; Srivastava, Vishal; Birla, Vikas; Rajput, Ashok; Pandit, Ramsagar

    2017-04-01

    Management of extra-articular distal humerus fractures presents a challenge to the treating surgeon due to the complex anatomy of the distal part of the humerus and complicated fracture morphology. Although surgical treatment has shown to provide a more stable reduction and alignment and predictable return to function, it has been associated with complications like iatrogenic radial nerve palsy, infection, non-union and Implant failure. We in the present series retrospectively analysed 20 patients with extra-articular distal humerus shaft fractures surgically treated using the extra-articular distal humeral locking plate approached by the triceps-sparing posterolateral approach. The outcome was assessed using the DASH score, range of motion at the elbow and the time to union. The mean time to radiographic fracture union was 12 weeks.

  5. Complications after pinning of supracondylar distal humerus fractures.

    Science.gov (United States)

    Bashyal, Ravi K; Chu, Jennifer Y; Schoenecker, Perry L; Dobbs, Matthew B; Luhmann, Scott J; Gordon, J Eric

    2009-01-01

    Supracondylar distal humerus fractures are one of the most common skeletal injuries in children. The current treatment of choice in North America is closed reduction and percutaneous pin fixation. Often surgeons leave the pins exposed beneath a cast but outside the skin. Great variation exists with respect to preoperative skin preparation, and perioperative antibiotic administration. Few data exist regarding the rate of infection and other complications. The purpose of this study is to review a large series of children to evaluate the rate of infection and other complications. A retrospective review was carried out of all patients treated at our institution over an 11-year period. A total of 622 patients were identified that were followed for a minimum of 2 weeks after pin removal. Seventeen patients had flexion-type fractures, 294 had type II fractures, and 311 had type III fractures. Seventy-four fractures (11.9%) had preoperative nerve deficits with anterior interosseous palsies being the most common (33 fractures, 5.3%). Preoperative antibiotics were given to 163 patients (26.2%). Spray and towel draping were used in 362 patients, paint and towel draping were used in 65 patients, alcohol paint and towel draping were used in 146 patients, and a full preparation and draping were used in 13 patients. The pins were left exposed under the cast in 591 fractures (95%), and buried beneath the skin in 31 fractures (5.0%). A medial pin was placed in 311 fractures with a small incision made to aid placement in 18 of these cases. The most common complication was pin migration necessitating unexpected return to the operating room for pin removal in 11 patients (1.8%). One patient developed a deep infection with septic arthritis and osteomyelitis (0.2%). Five additional patients had superficial skin infections and were treated with oral antibiotics for a total infection rate of 6 of 622 patients (1.0%). One patient ultimately had a malunion and 4 others returned to the

  6. The shaft fractures of the radius and ulna in children: current concepts.

    Science.gov (United States)

    Sinikumpu, Juha-Jaakko; Serlo, Willy

    2015-05-01

    The incidence of forearm shaft fractures in children has increased in recent years. They are challenging to treat and they can result in several long-lasting complications. The treatment of children's fractures needs to be individualized to their needs. Nonoperative care will be satisfactory for young, preschool children and it is primarily treatment in stable fractures of children at every age. Injury mechanism must be understood to perform appropriate closed reduction. Immobilization using a long-arm cast needs to be focused against the deforming muscle forces - in particular those that rotate - in the forearm, keeping the bones in alignment until bone healing. Operative stabilization by elastic stable intramedullary nailing is the primarily method of treatment in cases of unstable fractures, in particular, in children between preschool age and adolescence. For older children near to skeletal maturity, a rigid plate and screw fixation will be justified. The most common complication after closed treatment is worsening of the alignment and need for repetitive interventions. elastic stable intramedullary nailing results usually in good outcome, and range of forearm rotation is the main feature determining the clinical result. In this article, we report the current concept of paediatric shaft fractures in the radius and ulna.

  7. A three-dimensional analysis of the sigmoid notch

    Directory of Open Access Journals (Sweden)

    Evan D. Collins

    2011-12-01

    Full Text Available Fractures of the distal radius are among the most common injuries of the upper extremity, though treatment has traditionally focused on restoration of the radiocarpal joint and late sequelae may persist. X-ray imaging underestimates sigmoid notch involvement following distal radius fractures. No classification system exists for disruption patterns of the sigmoid notch of the radius associated with distal radius fractures. This study quantifies the anatomy of the sigmoid notch and identifies the landmarks of the articular surface and proximal boundaries of the distal radioulnar joint (DRUJ capsule. Computed tomography scans of freshly frozen cadaveric hands were used - followed by dissection, and three-dimensional reconstruction of the distal radius and sigmoid notch. The sigmoid notch surface was divided into two surfaces and measured. The Anterior Posterior (AP and Proximal Distal (PD widths of the articulating surface were reviewed, along with the radius of curvature, version angle and depth. The study showed that the sigmoid notch is flatter than previously believed - and only the distal 69% of its surface is covered by cartilage. On average, it has about nine degrees of retroversion, and its average inclination is almost parallel to the anatomical axis of the radius. Clinical implications exist for evaluation of the DRUJ involvement in distal radius fractures or degenerative diseases and for future development and evaluation of hemiarthroplasty replacement of the distal radius.

  8. Fractures of the distal phalanx and associated soft tissue and osseous abnormalities in 22 horses with ossified sclerotic ungual cartilages diagnosed with magnetic resonance imaging.

    Science.gov (United States)

    Selberg, Kurt; Werpy, Natasha

    2011-01-01

    Ungual cartilage ossification in the forelimb is a common finding in horses. Subtle abnormalities associated with the ungual cartilages can be difficult to identify on radiographs. Magnetic resonance (MR) imaging findings of 22 horses (23 forelimbs) with a fracture of the distal phalanx and ossified ungual cartilage were characterized and graded. All horses had a forelimb fracture. Eleven involved a left forelimb (seven medial; four lateral), and 12 involved a right forelimb (five medial; seven lateral). All fractures were nonarticular, simple in configuration, and nondisplaced. The fractures were oriented in an axial proximal to abaxial distal and palmar to dorsal direction, and extended from the base of the ossified ungual cartilage into the distal phalanx. The fracture involved the fossa of the collateral ligament on the distal phalanx in 17 of 23 limbs. The palmar process and ossified ungual cartilage was abnormally mineralized in all horses. Ligaments and soft tissues adjacent to the ossified ungual cartilages were affected in all horses. The routine site of fracture in this study at the base of the ossified ungual cartilage extending into the distal phalanx suggests a biomechanical cause or focal stress point from cycling. The ligamentous structures associated with the ungual cartilages were often affected, showed altered signal intensity as well as enlargement and were thought to be contributing to the lameness. In conclusion, ossified ungual cartilages may lead to fracture of the palmar process of the distal phalanx and injury of the ungual cartilage ligaments. © 2011 Veterinary Radiology & Ultrasound.

  9. Magnetic resonance imaging findings of periosteal interposition in a distal tibial Salter-Harris type I fracture with surgical correlation: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Nara; Jung, Jee Young; Kang, Ki Ser [Chung-Ang University Hospital, Seoul (Korea, Republic of)

    2013-08-15

    The complication of growth disturbance after physeal fracture of the distal tibia has been well recognized. Although irreducible fractures of the physis due to trapped soft tissue, including periosteum, are not common, it could still cause growth disturbances. Therefore, the detection of periosteal interposition with physeal injury on imaging study is important. We present a case of a 10-year-old girl with surgically confirmed periosteal interposition in the distal tibial Salter-Harris type I fracture, through magnetic resonance imaging findings.

  10. Magnetic resonance imaging findings of periosteal interposition in a distal tibial Salter-Harris type I fracture with surgical correlation: A case report

    International Nuclear Information System (INIS)

    Kim, Nara; Jung, Jee Young; Kang, Ki Ser

    2013-01-01

    The complication of growth disturbance after physeal fracture of the distal tibia has been well recognized. Although irreducible fractures of the physis due to trapped soft tissue, including periosteum, are not common, it could still cause growth disturbances. Therefore, the detection of periosteal interposition with physeal injury on imaging study is important. We present a case of a 10-year-old girl with surgically confirmed periosteal interposition in the distal tibial Salter-Harris type I fracture, through magnetic resonance imaging findings.

  11. [Role of centro-medullary nailing in fractures of the distal quarter of the leg: about 30 cases].

    Science.gov (United States)

    Margad, Omar; Boukhris, Jalal; Sallahi, Hicham; Azriouil, Ouahb; Daoudi, Mohamed; Koulali, Khalid

    2017-01-01

    The fractures of the distal quarter of the leg are characterized by fracture line located at the level of the lower quarter of the tibia, according to Gerard and Evrard definition [1]. They are serious and pose problems for consolidation, immobilization and stability. We here describe our experience in the Department of Orthopaedics and Traumatology at the Avicenne Military Hospital, Marrakech. We report 30 cases of closed fractures of the lower quarter of the leg treated with centro-medullary nailing over a period of 10 years (January 2001-December 2010). Locked nailing was performed in 80% of cases and simple nailing was performed in the other cases. The average age of patients was 36 years. There was a clear male predominance (27 men, 3 women). The average time for consolidation was 17 weeks and functional outcomes were satisfactory. A single case of infection occurred 6 months after surgery (3.3%) and no other complication was reported. Malunion was detected in 30% of patients. Our epidemiological data and results were almost identical to those in the literature. Angular results were significantly lower than those obtained with the series of plates. By contrast, data on infections called for caution and some nails produced excellent angular results when nail fixation was stable. In the light of these results, codified indications for locked centro-medullary nailing should be extended to the fractures of the lower quarter of the leg, provided that stable fixation using double screw distal locking and primary osteosynthesis of distal fibula fractures are performed.

  12. Effect of finite edge radius on ductile fracture ahead of the cutting tool edge in micro-cutting of Al2024-T3

    International Nuclear Information System (INIS)

    Subbiah, Sathyan; Melkote, Shreyes N.

    2008-01-01

    Evidence of ductile fracture leading to material separation has been reported recently in ductile metal cutting [S. Subbiah, S.N. Melkote, ASME J. Manuf. Sci. Eng. 28(3) (2006)]. This paper investigates the effect of finite edge radius on such ductile fracture. The basic question of whether such ductile fracture occurs in the presence of a finite edge radius is explored by performing a series of experiments with inserts of different edge radii at various uncut chip thickness values ranging from 15 to 105 μm. Chip-roots are obtained in these experiments using a quick-stop device and examined in a scanning electron microscope. Clear evidence of material separation is seen at the interface zone between the chip and machined surface even when the edge radius is large compared to the uncut chip thickness. Failure is seen to occur at the upper, middle, and/or the lower edges of the interface zone. Based on these observations, a hypothesis is presented for the events leading to the occurrence of this failure when cutting with an edge radius tool. Finite element simulations are performed to study the nature of stress state ahead of the tool edge with and without edge radius. Hydrostatic stress is seen to be tensile in front of the tool and hence favors the occurrence of ductile fracture leading to material separation. The stress components are, however lower than those seen with a sharp tool

  13. Pathological fracture in non-ossifying fibroma with histological features simulating aneurysmal bone cyst

    International Nuclear Information System (INIS)

    Hoeffel, C.; Mainard, L.; Hoeffel, J.C.; Panuel, M.; Plenat, F.

    1999-01-01

    A 12-year-old-girl presented with a fracture of an osteolytic lesion of the distal radius. A 7-year-old girl presented with a fracture of an osteolytic lesion of the femoral shaft. In both cases it was a non-ossifying fibroma with fracture misdiagnosed at pathology as aneurysmal bone cyst. Fractures through non-ossifying fibromas may alter the histological pattern of the initial lesion in two ways: firstly, by the presence of blood pigments due to the fracture, and secondly, by formation of new bone. Radiological-pathological correlation is essential to avoid histological errors after pathological fracture in a non-ossifying fibroma. (orig.)

  14. Comparison of 3 Minimally Invasive Methods for Distal Tibia Fractures.

    Science.gov (United States)

    Fang, Jun-Hao; Wu, Yao-Sen; Guo, Xiao-Shan; Sun, Liao-Jun

    2016-07-01

    This study compared the results of external fixation combined with limited open reduction and internal fixation (EF + LORIF), minimally invasive percutaneous plate osteosynthesis (MIPPO), and intramedullary nailing (IMN) for distal tibia fractures. A total of 84 patients with distal tibia shaft fractures were randomized to operative stabilization using EF + LORIF (28 cases), MIPPO (28 cases), or IMN (28 cases). The 3 groups were comparable with respect to patient demographics. Data were collected on operative time and radiation time, union time, complications, time of recovery to work, secondary operations, and measured joint function using the American Orthopaedic Foot and Ankle Society (AOFAS) score. There was no significant difference in time to union, incidence of union status, time of recovery to work, and AOFAS scores among the 3 groups (P>.05). Mean operative time and radiation time in the MIPPO group were longer than those in the IMN or EF + LORIF groups (Pknee pain occurred frequently after IMN (32.1%), and irritation symptoms were encountered more frequently after MIPPO (46.4%). Although EF + LORIF was associated with fewer secondary procedures vs MIPPO or IMN, it was related with more pin-tract infections (14.3%). Findings indicated that EF + LORIF, MIPPO, and IMN all achieved similar good functional results. However, EF + LORIF had some advantages over MIPPO and IMN in reducing operative and radiation times, postoperative complications, and reoperation rate. [Orthopedics. 2016; 39(4):e627-e633.]. Copyright 2016, SLACK Incorporated.

  15. Bilateral atypical insufficiency fractures of the proximal tibia and a unilateral distal femoral fracture associated with long-term intravenous bisphosphonate therapy: a case report

    Directory of Open Access Journals (Sweden)

    Imbuldeniya Arjuna

    2012-02-01

    Full Text Available Abstract Introduction Atypical insufficiency fractures of the femur in patients on long-term bisphosphonate therapy have been well described in recent literature. The majority of cases are associated with minimal or no trauma and occur in the subtrochanteric or diaphyseal region. Case presentation We describe the case of a 76-year-old British Caucasian woman who presented initially to an emergency department and then to her primary care physician with a long-standing history of bilateral knee pain after minor trauma. Plain radiographs showed subtle linear areas of sclerosis bilaterally in her proximal tibiae. Magnetic resonance imaging confirmed the presence of insufficiency fractures in these areas along with her left distal femur. There are very few reports of atypical insufficiency fractures involving the tibia in patients on long-term bisphosphonate therapy and this appears to be the only documented bilateral case involving the metaphyseal regions of the proximal tibia and distal femur. Conclusion In addition to existing literature describing atypical fractures in the proximal femur and femoral shaft, there is a need for increased awareness that these fractures can also occur in other weight-bearing areas of the skeleton. All clinicians involved in the care of patients taking long-term bisphosphonates need to be aware of the growing association between new onset lower limb pain and atypical insufficiency fractures.

  16. Appendicular and whole body lean mass outcomes are associated with finite element analysis-derived bone strength at the distal radius and tibia in adults aged 40years and older.

    Science.gov (United States)

    Gibbs, Jenna C; Giangregorio, Lora M; Wong, Andy K O; Josse, Robert G; Cheung, Angela M

    2017-10-01

    The purpose of this cross-sectional study was to determine how appendicular lean mass index (ALMI), and whole body lean (LMI) and fat mass indices (FMI) associate with estimated bone strength outcomes at the distal radius and tibia in adults aged 40 years and older. Dual energy X-ray absorptiometry (DXA) scans were performed to determine body composition, including whole body lean and fat mass, and appendicular lean mass. ALMI (appendicular lean mass/height 2 ), LMI (lean tissue mass/height 2 ) and FMI (fat mass/height 2 ) were calculated. High-resolution peripheral quantitative computed tomography (HRpQCT) scans were performed to assess bone structural properties at the distal radius and tibia. Using finite element analysis, failure load (N), stiffness (N/mm), ultimate stress (MPa), and cortical-to-trabecular load ratio were estimated from HRpQCT scans. The associations between body composition (ALMI, LMI, FMI) and estimated bone strength were examined using bivariate and multivariable linear regression analyses adjusting for age, sex, and other confounding variables. In 197 participants (127 women; mean±SD, age: 69.5±10.3y, body mass index: 27.95±4.95kg/m 2 , ALMI: 7.31±1.31kg/m 2 ), ALMI and LMI were significantly associated with failure load at the distal radius and tibia (explained 39%-48% of the variance) and remained significant after adjusting for confounding variables and multiple testing (R 2 =0.586-0.645, p<0.001). ALMI, LMI, and FMI did not have significant associations with ultimate stress in our multivariable models. FMI was significantly associated with cortical-to-trabecular load ratio at the distal radius and tibia (explained 6%-12% of the variance) and remained significant after adjusting for confounders and multiple testing (R 2 =0.208-0.243, p<0.001). FMI was no longer significantly associated with failure load after adjusting for confounders. These findings suggest that ALMI and LMI are important determinants of estimated bone strength

  17. No Higher Risk of CRPS After External Fixation of Distal Radial Fractures - Subgroup Analysis Under Randomised Vitamin C Prophylaxis.

    Science.gov (United States)

    Zollinger, Paul E; Kreis, Robert W; van der Meulen, Hub G; van der Elst, Maarten; Breederveld, Roelf S; Tuinebreijer, Wim E

    2010-02-17

    Operative and conservative treatment of wrist fractures might lead to complex regional pain syndrome (CRPS) type I.In our multicenter dose response study in which patients with distal radial fractures were randomly allocated to placebo or vitamin C in a daily dose of 200mg, 500mg or 1500mg during 50 days, an operated subgroup was analyzed.48 (of 427) fractures) were operated (11.2%). Twenty-nine patients (60%) were treated with external fixation, 14 patients (29%) with K-wiring according to Kapandji and five patients (10%) with internal plate fixation. The 379 remaining patients were treated with a plaster.In the operated group of patients who received vitamin C no CRPS (0/37) was seen in comparison with one case of CRPS (Kapandji technique) in the operated group who received placebo (1/11 = 9%, p=.23). There was no CRPS after external fixation.In the conservatively treated group 17 cases of CRPS (17/379 = 4.5%) occurred in comparison with one in case of CRPS in the operated group (1/48 = 2.1%, p=.71).External fixation doesn't necessarily lead to a higher incidence of CRPS in distal radial fractures. Vitamin C may also play a role in this. This subgroup analysis in operated distal radial fractures showed no CRPS occurrence with vitamin C prophylaxis.

  18. [Clinical application of blocking screws and rooting technique in the treatment of distal tibial fracture with interlocking intramedullary nail].

    Science.gov (United States)

    Zhu, Hai-Bing; Wu, Li-Guo; Fang, Zhi-Song; Luo, Cong-Feng; Wang, Qing-Feng; Ma, Yi-Ping; Gao, Hong; Fu, Guo-Hai; Hu, Cheng-Ting

    2012-07-01

    To introduce the clinical method of blocking screws and rooting technique in the treatment of distal tibial fracture with interlocking intramedullary nails. From June 2006 to March 2011, 26 patients with distal tibial fracture were treated with interlocking intramedullary nails using blocking screws and rooting technique, included 18 males and 8 females with an average age of 46.2 years old ranging from 24 to 64 years. According to AO classification: 10 cases of type A1, 4 cases of type A2, 8 cases of type B1, 4 cases of type B2. The average distance of the fractures end to the ankle joint was 85 mm ranging from 55 to 125 mm, the mean time between injured and operation was 4.5 days. The patients were evaluated with pain, range of motion, walking. All cases were followed-up for 6 to 22 months (averaged 15 months). According to Iowa ankle joint grading system,the score was improved from preoperative (66.8 +/- 8.2) to postoperative (94.6 +/- 4.8). All fractures had united, and got satisfactory reduction and stable fixation with no complications had happen such as breakage of screw. Fixation with interlocking intramedullary nail using blocking screws and rooting technique in treating distal tibial fracture, is a safe and effective technique for the improvement of stability.

  19. [Medial versus lateral plating in distal tibial fractures: a prospective study of 40 fractures].

    Science.gov (United States)

    Encinas-Ullán, C A; Fernandez-Fernandez, R; Rubio-Suárez, J C; Gil-Garay, E

    2013-01-01

    Tibial plafond fractures are one of the most challenging injuries in orthopaedic surgery. Their results could be improved by following the new guidelines for the management, and modern plating techniques. The results and complication rate between anteromedial and anterolateral approach for open reduction and internal fixation of these fractures were compared. A study was conducted on 40 patients treated by open reduction an internal fixation between 2007 and 2008. The surgical approach was selected by the surgeon in charge, depending on fracture pattern and skin situation. Patients were evaluated clinically and radiographically by an independent orthopaedic surgeon, not involved in the surgical procedure, using clinical (American Orthopaedic Foot and Ankle Society score) and radiological criteria at a minimum of two years. The appearance of complications after both approaches was recorded. Forty patients were included. The mean age was 53 years, with 24 males and 16 females. Seventeen of the injuries were of high energy, and there were 8 open fractures (3 of type i, 4 type ii and one type iii), and 12 of the closed injuries were grade ii or iii in the Tscherne classification. Six patients (15%) had associated injuries. At final follow-up there were 33 (82%) excellent or good results. No statistical differences were found between either surgical approach regarding time to bone union, rate of delayed union and infection rate. Three plates of the anteromedial group and none of the anterolateral group needed to be removed. Open reduction and internal fixation of distal tibia fractures produced reliable results, with no statistical differences found between anteromedial and anterolateral surgical approaches. Clinical and radiological results and complication rate were mainly related to the fracture type. Copyright © 2012 SECOT. Published by Elsevier Espana. All rights reserved.

  20. Perimenopausal risk of falling and incidence of distal forearm fracture.

    OpenAIRE

    Winner, S. J.; Morgan, C. A.; Evans, J. G.

    1989-01-01

    A postal survey of 2000 women and 2000 men sampled from the electoral roll in Oxford was undertaken to ascertain whether changes with age in the risk of falling might explain the stepwise increases in age specific incidence rates of distal forearm fracture which occur in women at around the age of 50. Corrected response rates were 83% for women and 72% for men. In women, but not in men, there was a rise in the risk of falling from 45 years, peaking in the 55-59 year age group, and sinking to ...

  1. Minimally-invasive treatment of high velocity intra-articular fractures of the distal tibia.

    LENUS (Irish Health Repository)

    Leonard, M

    2012-02-01

    The pilon fracture is a complex injury. The purpose of this study was to evaluate the outcome of minimally invasive techniques in management of these injuries. This was a prospective study of closed AO type C2 and C3 fractures managed by early (<36 hours) minimally invasive surgical intervention and physiotherapist led rehabilitation. Thirty patients with 32 intra-articular distal tibial fractures were treated by the senior surgeon (GK). Our aim was to record the outcome and all complications with a minimum two year follow-up. There were two superficial wound infections. One patient developed a non-union which required a formal open procedure. Another patient was symptomatic from a palpable plate inferiorly. An excellent AOFAS result was obtained in 83% (20\\/24) of the patients. Early minimally invasive reduction and fixation of complex high velocity pilon fractures gave very satisfactory results at a minimum of two years follow-up.

  2. The Distal Humerus Axial View: Assessment of Displacement in Medial Epicondyle Fractures.

    Science.gov (United States)

    Souder, Christopher D; Farnsworth, Christine L; McNeil, Natalie P; Bomar, James D; Edmonds, Eric W

    2015-01-01

    The assessment and treatment of childhood medial epicondyle humerus fractures continues to be associated with significant debate. Several studies demonstrate that standard radiographic views are unable to accurately portray the true displacement. Without reliable ways to assess the amount of displacement, how can we debate treatment and outcomes? This study introduces a novel imaging technique for the evaluation of medial epicondyle fractures. An osteotomy of a cadaveric humerus was performed to simulate a medial epicondyle fracture. Plain radiographs were obtained with the fracture fragment displaced anteriorly in 2-mm increments between 0 and 18 mm. Anteroposterior (AP), internal oblique (IR), lateral (LAT), and distal humerus axial (AXIAL) views were performed. Axial images were obtained by positioning the central ray above the shoulder at 15 to 20 degrees from the long axis of the humerus, centered on the distal humerus. Displacement (mm) was measured by 7 orthopaedic surgeons on digital radiographs. At 10 mm displacement, AP views underestimated displacement by 5.5±0.6 mm and IR views underestimated by 3.8±2.1 mm. On LAT views, readers were not able to visualize fragments with displacement. Displacement ≥10 mm from LAT views was overestimated by 1 reader by up to 4.6 mm and underestimated by others by up to 18.0 mm. AXIAL images more closely estimated the true amount of displacement, with a mean 1.5±1.1 mm error in measurement for displacement and a mean 0.8±0.7 mm error for displacements of ≥10 mm. AXIAL measurements correlated strongly with the actual displacement (r=0.998, Pdisplacement of medial epicondyle humerus fractures. The newly described AXIAL projection more accurately and reliably demonstrated the true displacement while reducing the need for advanced imaging such as computed tomography. This simple view can be easily obtained at a clinic visit, enhancing the surgeon's ability to determine the true displacement.

  3. Novel management of distal tibial and fibular fractures with Acumed fibular nail and minimally invasive plating osteosynthesis technique: A case report.

    Science.gov (United States)

    Wang, Tie-Jun; Ju, Wei-Na; Qi, Bao-Chang

    2017-03-01

    Anatomical characteristics, such as subcutaneous position and minimal muscle cover, contribute to the complexity of fractures of the distal third of the tibia and fibula. Severe damage to soft tissue and instability ensure high risk of delayed bone union and wound complications such as nonunion, infection, and necrosis. This case report discusses management in a 54-year-old woman who sustained fractures of the distal third of the left tibia and fibula, with damage to overlying soft tissue (swelling and blisters). Plating is accepted as the first choice for this type of fracture as it ensures accurate reduction and rigid fixation, but it increases the risk of complications. Closed fracture of the distal third of the left tibia and fibula (AO: 43-A3). After the swelling was alleviated, the patient underwent closed reduction and fixation with an Acumed fibular nail and minimally invasive plating osteosynthesis (MIPO), ensuring a smaller incision and minimal soft-tissue dissection. At the 1-year follow-up, the patient had recovered well and had regained satisfactory function in the treated limb. The Kofoed score of the left ankle was 95. Based on the experience from this case, the operation can be undertaken safely when the swelling has been alleviated. The minimal invasive technique represents the best approach. Considering the merits and good outcome in this case, we recommend the Acumed fibular nail and MIPO technique for treatment of distal tibial and fibular fractures.

  4. Exercise-induced rib stress fractures: influence of reduced bone mineral density

    DEFF Research Database (Denmark)

    Vinther, Anders; Kanstrup, Inge-Lis; Christiansen, Erik

    2005-01-01

    study investigated BMD in seven Danish national team rowers with previous rib stress fracture (RSF) and 7 controls (C) matched for gender, age, height, weight and training experience. Total body scan and specific scans of the lumbar spine (L2-L4), femoral neck and distal radius were performed using......Exercise-induced rib stress fractures have been reported frequently in elite rowers during the past decade. The etiology of rib stress fractures is unclear, but low bone mineral density (BMD) has been suggested to be a potential risk factor for stress fractures in weight-bearing bones. The present...... density may be a potential risk factor for the development of exercise-induced rib stress fractures in elite rowers....

  5. Role of Appositional Screw Fixation in Minimally Invasive Plate Osteosynthesis for Distal Tibial Fracture.

    Science.gov (United States)

    Yang, Kyu-Hyun; Won, Yougun; Kang, Dong-Hyun; Oh, Jin-Cheol; Kim, Sung-Jun

    2015-09-01

    To determine the effect of interfragmentary appositional (gap-closing) screw fixation in minimally invasive plate osteosynthesis (MIPO) for distal tibial fractures on the clinical and radiologic results. Prospective nonrandomized study. Level I trauma center. Sixty patients who were diagnosed as distal metadiaphyseal oblique or spiral tibial fracture without displaced articular fragment. Thirty patients (group A) of the 60 patients were treated with MIPO without appositional screw fixation, and the other 30 (group B) were treated with the screw. Radiologic union, clinical union, clinical functional score [American Orthopaedic Foot and Ankle Society (AOFAS) score], and complications. The time for initial callus formation and radiologic union was significantly longer in group A than those in group B (76.8 vs. 58.0 days, P = 0.044; 409 vs. 258.7 days, P = 0.002, respectively). The rate of clinical union during 1 year was significantly higher in group B than in group A (P = 0.0063). Four nonunion patients in group A achieved bone union after placement of an additional bone graft. None of the patients in group B diagnosed with delayed union or nonunion (P fracture promoted callus formation and union rate compared with MIPO without appositional screw fixation. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  6. Distal radius: anatomical morphometric gender characteristics. Do anatomical pre-shaped plates pay attention on it?

    Science.gov (United States)

    Oppermann, Johannes; Bredow, Jan; Beyer, Frank; Neiss, Wolfram Friedrich; Spies, Christian K; Eysel, Peer; Dargel, Jens; Wacker, Max

    2015-01-01

    The purpose of the study was to investigate differences in the osseous structure anatomy of male and female distal radii. Morphometric data were obtained of 49 distal human cadaveric radii. An imprint of the distal edge was attained using silicone mass and the palmar cortical angle (PCA) of the lateral and intermediate column, here declared as medial, according to the concept of Rikli and Rigazzoni. The lateral and medial length and five widths were digitally measured by three observers. In order to compare the measurements an unpaired t test was used. To prove the reliability of the measurements an intraclass correlation analyses was done. Overall mean medial PCA was 148.25° (SD ± 6.83) and mean lateral PCA 156.07° (SD ± 7.00). In male specimens, the mean medial PCA was 147.38° (SD ± 6.01) and mean lateral PCA was 153.6° (SD ± 6.20) whereas in female specimens, the mean medial PCA was 149.41° (SD ± 7.79) and the mean lateral PCA 159.37° (SD ± 6.78), with statistical significance for the female lateral PCA. No gender significant difference for the medial PCA and no significant side difference for the PCA's could be found. The ICC of the observers was r = 0.936 and 0.976 for the medial and for lateral PCA 0.957-0.984. The palmar cortical length of the distal radius was significantly longer in male specimens. For all widths, larger values for male radii were measured, being statistically significant in all cases. Male dimensions concerning the wide were significantly larger when compared with females. Regarding the PCA at the medial and lateral column, we found significant difference for lateral PCA concerning the gender. Overall, study results demonstrated an angle of 148.25° ± 6.83 for the medial PCA and 156.07° ± 7.00 for the lateral PCA.

  7. Fractura de radio distal: abordaje mininvasivo con preservación del pronador cuadrado. [Distal radius fracture: minimally invasive approach with pronator quadrates preservation.

    Directory of Open Access Journals (Sweden)

    Gabriel Clembosky

    2015-05-01

    Full Text Available Objetivo Describir y analizar una técnica de osteosíntesis palmar de radio distal con preservación del pronador cuadrado. Material y Métodos Se revisaron, en forma retrospectiva, 24 pacientes operados con esta técnica (16 mujeres y 8 hombres; edad promedio 65 años. Doce fracturas eran de tipo A; 7, de tipo B y 5, de tipo C. La técnica quirúrgica consiste en practicar una incisión cutánea de 25 mm y profundizar hasta observar el pronador cuadrado. Sin seccionarlo, se realiza una disección de su borde distal, a fin de introducir la placa bloqueada volar por debajo del músculo. Se colocan los tornillos distales bajo visión directa y los tornillos proximales, en forma percutánea. La evaluación posoperatoria se llevó a cabo mediante análisis clínico-funcional y radiográfico. Resultados En el último control, todos los pacientes presentaban signos clínicos y radiográficos de consolidación ósea. El puntaje en la escala DASH fue, en promedio, de 4,8. Se observó una inclinación palmar posoperatoria de la superficie articular del radio de 14,3º promedio y una inclinación radial de 26,3º promedio. No se detectaron complicaciones relacionadas con la fractura, el implante o la herida quirúrgica en ninguno de los controles posoperatorios. Conclusiones Sin bien no existe bibliografía que demuestre que la técnica mininvasiva sea superior, sostenemos que el hecho de obtener resultados similares con ambos abordajes (mininvasivo y convencional justifica llevar a cabo esta técnica con preservación del pronador cuadrado, sobre todo en los pacientes preocupados por el aspecto cosmético de la cicatriz.

  8. Does Wrist Arthrodesis With Structural Iliac Crest Bone Graft After Wide Resection of Distal Radius Giant Cell Tumor Result in Satisfactory Function and Local Control?

    Science.gov (United States)

    Wang, Tao; Chan, Chung Ming; Yu, Feng; Li, Yuan; Niu, Xiaohui

    2017-03-01

    Many techniques have been described for reconstruction after distal radius resection for giant cell tumor with none being clearly superior. The favored technique at our institution is total wrist fusion with autogenous nonvascularized structural iliac crest bone graft because it is structurally robust, avoids the complications associated with obtaining autologous fibula graft, and is useful in areas where bone banks are not available. However, the success of arthrodesis and the functional outcomes with this approach, to our knowledge, have only been limitedly reported. (1) What is the success of union of these grafts and how long does it take? (2) How effective is the technique in achieving tumor control? (3) What complications occur with this type of arthrodesis? (4) What are the functional results of wrist arthrodesis by this technique for treating giant cell tumor of the distal radius? Between 2005 and 2013, 48 patients were treated for biopsy-confirmed Campanacci Grade III giant cell tumor of the distal radius. Of those, 39 (81% [39 of 48]) were treated with wrist arthrodesis using autogenous nonvascularized iliac crest bone graft. Of those, 27 (69% [27 of 39]) were available for followup at a minimum of 24 months (mean, 45 months; range, 24-103 months). During that period, the general indications for this approach were Campanacci Grade III and estimated resection length of 8 cm or less. Followup included clinical and radiographic assessment and functional assessment using the Disabilities of the Arm, Shoulder and Hand (DASH) score, the Musculoskeletal Tumor Society (MSTS) score, grip strength, and range of motion at every followup by the treating surgeon and his team. All functional results were from the latest followup of each patient. Union of the distal junction occurred at a mean of 4 months (± 2 months) and union of the proximal junction occurred at a mean of 9 months (± 5 months). Accounting for competing events, at 12 months, the rate of proximal

  9. Anatomical study of the radius and center of curvature of the distal femoral condyle

    KAUST Repository

    Kosel, Jü rgen; Giouroudi, Ioanna; Scheffer, Cornie; Dillon, Edwin Mark; Erasmus, Pieter J.

    2010-01-01

    In this anatomical study, the anteroposterior curvature of the surface of 16 cadaveric distal femurs was examined in terms of radii and center point. Those two parameters attract high interest due to their significance for total knee arthroplasty. Basically, two different conclusions have been drawn in foregoing studies: (1) The curvature shows a constant radius and (2) the curvature shows a variable radius. The investigations were based on a new method combining three-dimensional laser-scanning and planar geometrical analyses. This method is aimed at providing high accuracy and high local resolution. The high-precision laser scanning enables the exact reproduction of the distal femurs - including their cartilage tissue - as a three-dimensional computer model. The surface curvature was investigated on intersection planes that were oriented perpendicularly to the surgical epicondylar line. Three planes were placed at the central part of each condyle. The intersection of either plane with the femur model was approximated with the help of a b-spline, yielding three b-splines on each condyle. The radii and center points of the circles, approximating the local curvature of the b-splines, were then evaluated. The results from all three b-splines were averaged in order to increase the reliability of the method. The results show the variation in the surface curvatures of the investigated samples of condyles. These variations are expressed in the pattern of the center points and the radii of the curvatures. The standard deviations of the radii for a 90 deg arc on the posterior condyle range from 0.6 mm up to 5.1 mm, with an average of 2.4 mm laterally and 2.2 mm medially. No correlation was found between the curvature of the lateral and medial condyles. Within the range of the investigated 16 samples, the conclusion can be drawn that the condyle surface curvature is not constant and different for all specimens when viewed along the surgical epicondylar axis. For the portion

  10. Quantitative comparison of bone mineral density characteristics of the distal epiphysis of third metacarpal bones from Thoroughbred racehorses with or without condylar fracture.

    Science.gov (United States)

    Bogers, Sophie H; Rogers, Chris W; Bolwell, Charlotte; Roe, Wendi; Gee, Erica; McIlwraith, C Wayne

    2016-01-01

    To compare regional proportions and spatial distributions of volumetric bone mineral density (BMDv) of the palmar aspect of the distal epiphysis of the third metacarpal bone (McIII) in limbs with or without a condylar fracture from Thoroughbred racehorses. McIIIs from cadavers of Thoroughbred racehorses with (n = 6 bones) and without (8) a condylar fracture. BMDv and spatial distributions of BMDv in peripheral quantitative CT images of the distal epiphysis of McIIIs were quantitatively assessed with spatial analysis software. Relative proportions of voxels within 9 threshold categories of BMDv and spatial statistics for BMDv distribution were compared between fractured and nonfractured limbs. No significant differences in BMDv characteristics were identified between fractured and nonfractured limbs, although fractured limbs had a lower proportion of voxels in the BMDv thresholds 700 to bone to race training rather than differences between fractured and nonfractured limbs. In both limb groups, uniform clusters of low BMDv with areas of high BMDv were identified. BMDv characteristics of the distal epiphysis of McIII reflected training load, and fracture characteristics were subtle. Serial imaging techniques in conjunction with detailed training data are required to elucidate the onset of the pathological response to load in horses.

  11. [Distal fixation prosthesis for unstable intertrochanteric fractures in elderly patients: a mid-term follow-up study].

    Science.gov (United States)

    Zhang, Zhan-feng; Min, Ji-kang; Zhong, Jian-ming; Wang, Dan

    2016-06-01

    To explore mid-term follow up results of distal fixation prosthesis in treating unstable intertrochanteric fractures in elderly patients. From May 2008 to March 2014,58 elderly patients with unstable intertrochanteric were treated with distal fixation prosthesis, among them, there were 15 males and 43 females aged from 75 to 87 years old with an average of 83.2 years old. Fracture were classified according to Evans classification, 39 cases were type I c and 19 cases were type I d. Surgical risk was evaluated before operation, 9 patients were performed total hip arthroplasty and 49 patients were performed prosthetic replacement hip joint function of patients with different age period, Evans classificaton, prothesis type, fixation method were evaluated respectively by using Harris score. Fifty-six patients were followed up from 13 to 36 months with an average of 21.6 months. Harris score was 83.51 ± 6.40, 5 cases got excellent results, 38 cases good and 13 cases moderate. Harris score of patients aged from 75 to 80 years old was 88.64 ± 2.35, 81.64 ± 6.40 in patients aged more than 80 years old, and had significant differences between two groups; Harris score in patients with type Evans I c was 83.64 ± 6.53, and 83.11 ± 6.08 in type Evans I d, while there was no significant differences between two groups. There was no obvious meaning in Harris score between patients with tension band (83.63 ± 6.15) and without tension band (82.41 ± 6.57). There was no significant meaning in Harris score between patients with normal distal fixation prosthesis (83.34 ± 6.43) and femoral moment reconstruction distal fixation prosthesis (83.92 ± 6.51). There was 1 patient occurred hip joint dislocation on the operative side and re-dislocation after manual reduction, then received open reduction. Two patients occurred femoral osteolysis without clinical symptoms, and treated conservative treatment. Artificial joint replacement for unstable intertrochanteric fractures in elderly

  12. A comparative study of intramedullary interlocking nailing and minimally invasive plate osteosynthesis in extra articular distal tibial fractures.

    Science.gov (United States)

    Daolagupu, Arup K; Mudgal, Ashwani; Agarwala, Vikash; Dutta, Kaushik K

    2017-01-01

    Extraarticular distal tibial fractures are among the most challenging fractures encountered by an orthopedician for treatment because of its subcutaneous location, poor blood supply and decreased muscular cover anteriorly, complications such as delayed union, nonunion, wound infection, and wound dehiscence are often seen as a great challenge to the surgeon. Minimally invasive plate osteosynthesis (MIPO) and intramedullary interlocking nail (IMLN) are two well-accepted and effective methods, but each has been historically related to complications. This study compares clinical and radiological outcome in extraarticular distal tibia fractures treated by intramedullary interlocking nail (IMLN) and minimally invasive plate osteosynthesis (MIPO). 42 patients included in this study, 21 underwent IMLN and 21 were treated with MIPO who met the inclusion criteria and operated between June 2014 and May 2015. Patients were followed up for clinical and radiological evaluation. In IMLN group, average union time was 18.26 weeks compared to 21.70 weeks in plating group which was significant ( P ankle stiffness, and infection, were seen in interlocking group as compared to plating group. Average functional outcome according to American Orthopedic Foot and Ankle Society score was measured which came out to be 96.67. IMLN group was associated with lesser duration of surgery, earlier weight bearing and union rate, lesser incidence of infection and implant irritation which makes it a preferable choice for fixation of extra-articular distal tibial fractures. However, larger randomized controlled trials are required for confirming the results.

  13. Size-corrected BMD decreases during peak linear growth: implications for fracture incidence during adolescence.

    Science.gov (United States)

    Faulkner, Robert A; Davison, K Shawn; Bailey, Donald A; Mirwald, Robert L; Baxter-Jones, Adam D G

    2006-12-01

    Peak adolescent fracture incidence at the distal end of the radius coincides with a decline in size-corrected BMD in both boys and girls. Peak gains in bone area preceded peak gains in BMC in a longitudinal sample of boys and girls, supporting the theory that the dissociation between skeletal expansion and skeletal mineralization results in a period of relative bone weakness. The high incidence of fracture in adolescence may be related to a period of relative skeletal fragility resulting from dissociation between bone expansion and bone mineralization during the growing years. The aim of this study was to examine the relationship between changes in size-corrected BMD (BMDsc) and peak distal radius fracture incidence in boys and girls. Subjects were 41 boys and 46 girls measured annually (DXA; Hologic 2000) over the adolescent growth period and again in young adulthood. Ages of peak height velocity (PHV), peak BMC velocity (PBMCV), and peak bone area (BA) velocity (PBAV) were determined for each child. To control for maturational differences, subjects were aligned on PHV. BMDsc was calculated by first regressing the natural logarithms of BMC and BA. The power coefficient (pc) values from this analysis were used as follows: BMDsc = BMC/BA(pc). BMDsc decreased significantly before the age of PHV and then increased until 4 years after PHV. The peak rates in radial fractures (reported from previous work) in both boys and girls coincided with the age of negative velocity in BMDsc; the age of peak BA velocity (PBAV) preceded the age of peak BMC velocity (PBMCV) by 0.5 years in both boys and girls. There is a clear dissociation between PBMCV and PBAV in boys and girls. BMDsc declines before age of PHV before rebounding after PHV. The timing of these events coincides directly with reported fracture rates of the distal end of the radius. Thus, the results support the theory that there is a period of relative skeletal weakness during the adolescent growth period caused, in

  14. Changing incidence and residual lifetime risk of common osteoporosis-related fractures

    DEFF Research Database (Denmark)

    Lauritzen, J B; Schwarz, Peter; Lund, B

    1993-01-01

    1735 fractures of the distal radius, 747 fractures of the proximal humerus, 878 cervical and 635 trochanteric hip fractures were included. In men 273 cervical and 232 trochanteric hip fractures were included. The fractures were registered during the period 1976 to 1984 and changes in age.......05) during the observation period, while no significant decrease was found in the incidence of trochanteric fractures. No significant changes in incidence were observed in women with radial or humeral fractures, or in men with hip fractures. A women 60 years old with a life expectancy of 81 years had......Changes in incidence and lifetime risk of fractures are of major importance in the epidemiology of osteoporosis. We focused on hip fractures in women and men and on radial and humeral fractures in women. The study subjects comprised 4500 women and men 20 years old or more with fractures. In women...

  15. The Relationship Between Fractures and DXA Measures of BMD in the Distal Femur of Children and Adolescents With Cerebral Palsy or Muscular Dystrophy

    Science.gov (United States)

    Henderson, Richard C; Berglund, Lisa M; May, Ryan; Zemel, Babette S; Grossberg, Richard I; Johnson, Julie; Plotkin, Horacio; Stevenson, Richard D; Szalay, Elizabeth; Wong, Brenda; Kecskemethy, Heidi H; Harcke, H Theodore

    2010-01-01

    Children with limited or no ability to ambulate frequently sustain fragility fractures. Joint contractures, scoliosis, hip dysplasia, and metallic implants often prevent reliable measures of bone mineral density (BMD) in the proximal femur and lumbar spine, where BMD is commonly measured. Further, the relevance of lumbar spine BMD to fracture risk in this population is questionable. In an effort to obtain bone density measures that are both technically feasible and clinically relevant, a technique was developed involving dual-energy X-ray absorptiometry (DXA) measures of the distal femur projected in the lateral plane. The purpose of this study is to test the hypothesis that these new measures of BMD correlate with fractures in children with limited or no ability to ambulate. The relationship between distal femur BMD Z-scores and fracture history was assessed in a cross-sectional study of 619 children aged 6 to 18 years with muscular dystrophy or moderate to severe cerebral palsy compiled from eight centers. There was a strong correlation between fracture history and BMD Z-scores in the distal femur; 35% to 42% of those with BMD Z-scores less than −5 had fractured compared with 13% to 15% of those with BMD Z-scores greater than −1. Risk ratios were 1.06 to 1.15 (95% confidence interval 1.04–1.22), meaning a 6% to 15% increased risk of fracture with each 1.0 decrease in BMD Z-score. In clinical practice, DXA measure of BMD in the distal femur is the technique of choice for the assessment of children with impaired mobility. © 2010 American Society for Bone and Mineral Research PMID:19821773

  16. Treatment of lithic tumors of the distal ending of the radius: Results of two surgical techniques in a series of cases

    International Nuclear Information System (INIS)

    Escandon, Santiago; Soto, Camilo; Pulido, Edgar

    2003-01-01

    The distal ending of the radius can bear several tumors with different degrees of aggressiveness that depend on the extension of the tumor. Their treatment varies according to the aggressiveness it and can include curettage only or may require more extensive surgical procedures including, in some cases reconstructive surgery. The present study describes two surgical reconstructive techniques and their results in a series of cases. Five patients underwent radio-carpal, and three Ulnar-carpal arthrodesis with non-vascularized autologous bone graft from the iliac crest. Pathology diagnosis included: six giant cell tumors, one Ewing's sarcoma, and one chondroblastoma. There were five males and three females, with an average age of 34.6 years (rank: 17-52). All the patients underwent wide surgical resection of the tumor, and only the patient with the Ewing's sarcoma received additionally adjuvant chemotherapy and radiotherapy. Five patients had compromise of the surrounding soft tissues. Two had limitation of movement of the fingers, and one hypoesthesia. One patient with ulnar arthrodesis had a fracture of the cubitus, at the proximal ending of the plate, secondary to trauma. AII patients have been followed for an average time of 12.8 months (rank: 0.5-72). There have been no episodes of infection. Neither non-union of the osteotomies, nor failures of fixation or recurrences were observed

  17. Stress Fractures of the Distal Femur Involving Small Nonossifying Fibromas in Young Athletes.

    Science.gov (United States)

    Robertson, Michael; Gilley, Jasen; Nicholas, Richard

    2016-11-01

    Small nonossifying fibromas (ie, fibrocortical defects) are incidental findings commonly seen on radiographs of young patients evaluated for extremity pain or sport-related trauma. Although pathological fractures have been reported in larger lesions, the subcentimeter, intracortical defects are not generally thought to predispose to pathological fractures. The authors report on 2 young athletes who presented with knee pain after initiating conditioning exercise programs (cross-training). Both were diagnosed with transverse metaphyseal stress fractures involving fibrous cortical defects of the distal femur. Initial radiographs were interpreted without evidence of fractures. However, subsequent magnetic resonance imaging was informative, suggesting that magnetic resonance imaging may have value in identifying potential stress reactions in young athletes. In addition, subsequent plain radiographs of both patients showed subperiosteal new bone formation in these nondisplaced fractures, suggesting that serial radiographs and close clinical follow-up are warranted for patients with persistent symptoms. The authors propose that, in the appropriate clinical setting, the presence of a small nonossifying fibroma may be a clinical indication that further evaluation is needed when plain radiographs show normal findings, as the defect could be an unrecognized area of fracture initiation. [Orthopedics. 2016; 39(6):e1197-e1200.]. Copyright 2016, SLACK Incorporated.

  18. Surgical treatment of distal tibia fractures: open versus MIPO.

    Science.gov (United States)

    Gülabi, Deniz; Bekler, Halil İbrahim; Sağlam, Fevzi; Taşdemir, Zeki; Çeçen, Gültekin Sıtkı; Elmalı, Nurzat

    2016-01-01

    Treatment of the distal tibial fractures are challenging due to the limited soft tissue, subcutaneous location and poor vascularity. In this control-matched study, it was aimed to compare the traditional open reduction and internal fixation with minimal invasive plating (MIPO). We hypothesized that superior results may be achieved with MIPO technique. 22 patients treated with traditional open reduction and internal fixation were matched with 22 patients treated with closed reduction and MIPO on the basis of age (±3), gender, and fracture pattern (AO classification). Evaluation was assed according to the wound problems, the American Orthopaedic Foot and Ankle surgery (AOFAS) scoring, radiological union, malunion, delayed union, hospitalisation time, time from injury to surgery, and operation time. There was no significant difference in the distribution of AO/OTA classification, age, gender, AOFAS score, time from injury to operation, follow-up, bone union time, delayed union, malunion and infection (p>0.05). The operation time was significantly longer in the open group than in the MIPO group: 69.59±7.21 min. for the ORIF, and 61.14±5.61 for the MIPO group (pfractures with reduced hospital stay, cost-effectiveness, and infection rate.

  19. Diabetes and change in bone mineral density at the hip, calcaneus, spine, and radius in older women

    Directory of Open Access Journals (Sweden)

    Ann V. Schwartz

    2013-05-01

    Full Text Available Older women with type 2 diabetes mellitus (DM have higher bone mineral density (BMD but also have higher rates of fracture compared to those without DM. Limited evidence suggests that DM may also be associated with more rapid bone loss. To determine if bone loss rates differ by DM status in older women, we analyzed BMD data in the Study of Osteoporotic Fractures (SOF between 1986 and 1998. SOF participants were women >65 years at baseline who were recruited from four regions in the U.S. DM was ascertained by self-report. BMD was measured with dual x-ray absorptiometry (DXA at baseline and at least one follow-up visit at the hip (N=6624 and calcaneus (N=6700 and, on a subset of women, at the spine (N=396 and distal radius (N=306. Annualized percent change in BMD was compared by DM status, using random effects models. Of 6,867 women with at least one follow-up DXA scan, 409 had DM at baseline. Mean age was 70.8 (SD 4.7 years. Baseline BMD was higher in women with DM at all measured sites. In models adjusted for age and clinic, women with prevalent DM lost bone more rapidly than those without DM at the femoral neck (-0.96% vs. -0.59% per year, p < 0.001, total hip (-0.98% vs. -0.70% per year, p<0.001, calcaneus (-1.64% vs. -1.40% per year, p=0.005, and spine (-0.33% vs. +0.33% per year, p=0.033, but not at the distal radius (-0.97% vs. -0.90% per year, p=0.91. These findings suggest that despite higher baseline BMD, older women with DM experience more rapid bone loss than those without DM at the hip, spine and calcaneus, but not the radius. Higher rates of bone loss may partially explain higher fracture rates in older women with DM.

  20. Dynamic intramedullary crosspinning technique for repair of distal femoral fractures in dogs and cats: 71 cases (1981-1985)

    International Nuclear Information System (INIS)

    Whitney, W.O.; Schrader, S.C.

    1987-01-01

    Dynamic intramedullary crosspinning was used in the surgical treatment of supracondylar and distal physeal fractures of the femur in 129 dogs and cats over a 5-year period; the records of the 44 dogs and 27 cats with follow-up information up to time of bony union were evaluated. The results were good or excellent in 66 of 71 animals (93%). The mean follow-up period was 22 months. Distal pin migration was the major complication (10 animals; 14%). The pin migrated before bony union in 2 animals because of instability and collapse at the fracture site. The pin migrated in 8 animals after bony union and was associated with intermittent lameness. In 5 of these, pin removal was performed and the lameness resolved

  1. Effectiveness of various isometric exercises at improving bone strength in cortical regions prone to distal tibial stress fractures.

    Science.gov (United States)

    Florio, C S

    2018-06-01

    A computational model was used to compare the local bone strengthening effectiveness of various isometric exercises that may reduce the likelihood of distal tibial stress fractures. The developed model predicts local endosteal and periosteal cortical accretion and resorption based on relative local and global measures of the tibial stress state and its surface variation. Using a multisegment 3-dimensional leg model, tibia shape adaptations due to 33 combinations of hip, knee, and ankle joint angles and the direction of a single or sequential series of generated isometric resultant forces were predicted. The maximum stress at a common fracture-prone region in each optimized geometry was compared under likely stress fracture-inducing midstance jogging conditions. No direct correlations were found between stress reductions over an initially uniform circular hollow cylindrical geometry under these critical design conditions and the exercise-based sets of active muscles, joint angles, or individual muscle force and local stress magnitudes. Additionally, typically favorable increases in cross-sectional geometric measures did not guarantee stress decreases at these locations. Instead, tibial stress distributions under the exercise conditions best predicted strengthening ability. Exercises producing larger anterior distal stresses created optimized tibia shapes that better resisted the high midstance jogging bending stresses. Bent leg configurations generating anteriorly directed or inferiorly directed resultant forces created favorable adaptations. None of the studied loads produced by a straight leg was significantly advantageous. These predictions and the insight gained can provide preliminary guidance in the screening and development of targeted bone strengthening techniques for those susceptible to distal tibial stress fractures. Copyright © 2018 John Wiley & Sons, Ltd.

  2. Effect of different surgical methods on traumatic response degree and osteoblast-osteoclast balance in patients with distal tibial fracture

    Directory of Open Access Journals (Sweden)

    Yun-Qiang Fan

    2017-01-01

    Full Text Available Objective: To study the effect of different surgical methods on trauma response degree and osteoblast-osteoclast balance in patients with distal tibial fracture. Methods: 58 cases of patients with distal tibial fracture who received open reduction and internal fixation in Orthopedics Department of our hospital from May 2013 to October 2015 were selected as research subjects and divided into delayed group (n = 29 and routine group (n = 29 according to different timing of surgery. Delayed group received open reduction and internal fixation 7–15 d after trauma and routine group received open reduction and internal fixation within 24 h after trauma. Levels of serum stress response indicators and osteoblast-osteoclast markers were compared between two groups. Results: On the day after operation, serum adrenocorticotropic hormone, cortisol, renin, angiotensin II, epinephrine and norepinephrine levels of delayed group were significantly lower than those of control group (P<0.05; on the 7th day after operation, serum osteocalcin, procollagen type I carboxyl-terminal peptide and bone alkaline phosphatase of delayed group were significantly higher than those of control group (P<0.05 while cross-linked carboxyl-terminal telopeptide of type I collagen and tartrate-resistant acid phosphatase isoform 5b levels were significantly lower than those of control group (P<0.05. Conclusions: Delayed open reduction and internal fixation treatment of distal tibial fracture can reduce the trauma caused by surgical procedures, increase osteoblast viability and inhibit osteoclast viability, which are conducive to fracture healing.

  3. Emprego de fixador externo circular no tratamento de complicações de fraturas do rádio e ulna em cães de raças pequenas Use of circular external fixator in the treatment of fracture complications of radius and ulna in small breed dogs

    Directory of Open Access Journals (Sweden)

    Sheila Canevese Rahal

    2005-10-01

    Full Text Available O objetivo deste estudo foi avaliar o método de Ilizarov no tratamento de complicações de fraturas do rádio e ulna em cães de raças pequenas. Um fixador de Ilizarov miniatura composto por anéis de alumínio e hastes de aço foi usado em três cães da raça poodle miniatura (casos 1, 2 e 3 e em um pinscher (caso 4. Os cães 1 e 4 apresentavam consolidação atrasada das porções médio-distal e distal, respectivamente, devido a prévio tratamento com tala externa. Foi aplicada uma montagem constituída por dois anéis proximais e um distal. Ambas as fraturas consolidaram, sendo que a do poodle apresentou leve desvio cranial das extremidades fraturadas. Os outros dois casos (2 e 3 consistiam de fraturas previamente tratadas por procedimento cirúrgico. O caso 2 apresentava rotação lateral do membro torácico e não-união do aspecto distal da diáfise radial com presença de pino intramedular e dois fios de cerclagem. O pino intramedular e um dos fios de cerclagem foram removidos e realizou-se a derrotação do foco da fratura. O aparelho foi montado como nos casos 1 e 4. A consolidação da fratura foi obtida com moderado desvio caudal do eixo ósseo. No caso 3, havia reabsorção óssea na diáfise do rádio e ulna devido ao emprego inadequado de fixador externo resina-pino. Empregou-se o transporte ósseo com o fixador de Ilizarov para induzir a regeneração óssea. Entretanto, este foi interrompido por falta de resposta. Manteve-se o fixador e o defeito ósseo foi tratado com enxerto esponjoso autólogo e biomateriais. A ulna ocupou parte do defeito segmentar do rádio. Foi possível concluir que o método de Ilizarov pode ser usado no tratamento de consolidação atrasada e não-união, mas o fixador externo circular é de difícil aplicação em cães de raças pequenas.The aim of this study was to evaluate the Ilizarov’s method for treating complications of radius and ulna fractures in small breed dogs. A miniature Ilizarov

  4. Comparison of computer assisted surgery with conventional technique for treatment of abaxial distal phalanx fractures in horses: an in vitro study.

    Science.gov (United States)

    Rossol, Melanie; Gygax, Diego; Andritzky-Waas, Juliane; Zheng, Guoyan; Lischer, Christoph J; Zhang, Xuan; Auer, Joerg A

    2008-01-01

    To (1) evaluate and compare computer-assisted surgery (CAS) with conventional screw insertion (conventional osteosynthesis [COS]) for treatment of equine abaxial distal phalanx fractures; (2) compare planned screw position with actual postoperative position; and (3) determine preferred screw insertion direction. Experimental study. Cadaveric equine limbs (n=32). In 8 specimens each, a 4.5 mm cortex bone screw was inserted in lag fashion in dorsopalmar (plantar) direction using CAS or COS. In 2 other groups of 8, the screws were inserted in opposite direction. Precision of CAS was determined by comparison of planned and actual screw position. Preferred screw direction was also assessed for CAS and COS. In 4 of 6 direct comparisons, screw positioning was significantly better with CAS. Results of precision analysis for screw position were similar to studies published in human medicine. None of evaluated criteria identified a preferred direction for screw insertion. For abaxial fractures of the distal phalanx, superior precision in screw position is achieved with CAS technique compared with COS technique. Abaxial fractures of the distal phalanx lend themselves to computer-assisted implantation of 1 screw in a dorsopalmar (plantar) direction. Because of the complex anatomic relationships, and our results, we discourage use of COS technique for repair of this fracture type.

  5. Adolescent Volar Barton Fracture with Open Physis treated with Volar Plating using Buttressing Principle

    Directory of Open Access Journals (Sweden)

    Shah H

    2015-07-01

    Full Text Available Objective: The objective of the study was to assess the outcome of Salter- Harris type III distal radius fracture fixed using the principle of buttressing and avoiding screw insertion through the physis. Materials and Method: Eight school going children in the age group of 11-16 years with volar Barton fractures were treated with a volar plate using the buttress principle without inserting screws in the distal fragment. Patients were evaluated over a period of 18 months. Clinical evaluation was done using the Green O’Brien criteria and radiological evaluation using the Sarmiento criteria. Results: The average union time was two months. All the patients had good to excellent functional outcome with full extension and flexion. Conclusion: Buttress plating of volar Barton fractures in the adolescent age group is an excellent technique to achieve satisfactory outcome without violation of the physis.

  6. A case report of an isolated fracture through the radial bicipital tuberosity

    Directory of Open Access Journals (Sweden)

    Kanta Imao

    Full Text Available Introduction: Generally, anatomical reduction of shaft fractures through operative treatment is necessary to restore the anatomical relationship of the forearm bones. However, a number of nerves and vessels are located in the proximal radius, which complicates surgery. In this study, we aimed to reduce postoperative complications by using a posterior approach. Presentation of case: We describe an isolated fracture through the radial bicipital tuberosity in a 69-year-old man caused by direct blunt force and our management of the fracture. The patient underwent an operation for the fracture under brachial plexus block. The injury was explored using the posterior approach, and plate fixation was performed after confirming the absence of obstacles to rotation on pronation and supination. One year later, the patient did not have any difficulties in activities of daily living. Discussion: Since an isolated fracture through the radial bicipital tuberosity is more distal than the radial head and neck and more proximal than a common radius diaphysis fracture, we had to consider a different operative approach. The nerve and blood vessels of the forearm, such as the radial nerve and artery, run in a complicated fashion around the proximal radius; thus, we chose the posterior approach because of its simpler surgical technique and lower complication risk, compared with the anterior approach. Conclusion: Surgeons can obtain a favorable treatment result using the posterior approach to the fracture and reduce complications by ensuring with rigid fixation using a locking plate. Keywords: Radial bicipital tuberosity, Posterior approach, Posterior interosseous nerve, Shaft fracture

  7. Low volumetric BMD is linked to upper-limb fracture in pubertal girls and persists into adulthood: a seven-year cohort study.

    Science.gov (United States)

    Cheng, Sulin; Xu, Leiting; Nicholson, Patrick H F; Tylavsky, Frances; Lyytikäinen, Arja; Wang, Qingju; Suominen, Harri; Kujala, Urho M; Kröger, Heikki; Alen, Markku

    2009-09-01

    The aetiology of increased incidence of fracture during puberty is unclear. This study aimed to determine whether low volumetric bone mineral density (vBMD) in the distal radius is associated with upper-limb fractures in growing girls, and whether any such vBMD deficit persists into adulthood. Fracture history from birth to 20 years was obtained and verified by medical records in 1034 Finnish girls aged 10-13 years. Bone density and geometry at distal radius, biomarkers and lifestyle/behavioural factors were assessed in a subset of 396 girls with a 7.5-year follow-up. We found that fracture incidence peaked during puberty (relative risk 3.1 at age of 8-14 years compared to outside this age window), and 38% of fractures were in the upper-limb. Compared to the non-fracture cohort, girls who sustained upper-limb fracture at ages 8-14 years had lower distal radial vBMD at baseline (258.9+/-37.5 vs. 287.5+/-34.1 mg/cm(3), p=0.001), 1-year (252.0+/-29.3 vs. 282.6+/-33.5 mg/cm(3), p=0.001), 2-year (258.9+/-32.2 vs. 289.9+/-40.1 mg/cm(3), p=0.003), and 7-year follow-ups (early adulthood, 307.6+/-35.9 vs. 343.6+/-40.9 mg/cm(3), p=0.002). There was a consistent trend towards larger bone cross-sectional area in the fracture cohort compared to non-fracture. In a logistic regression model, lower vBMD (p=0.001) was the only significant predictor of upper-limb fracture during the period of 8-14 years. Our results indicate that low BMD is an important factor underlying elevated upper-limb fracture risk during puberty, and that low BMD in pubertal girls with fracture persists into adulthood. Hence low vBMD during childhood is not a transient deficit. Methods to monitor vBMD and to maximise bone mineral accrual and reduce risks of falling in childhood should be developed.

  8. [Complications of treatment of acromioclavicular joint dislocation and unstable distal clavicular fracture with clavicular hook plate].

    Science.gov (United States)

    Zhu, Yi-Yong; Cui, Heng-Yan; Jiang, Pan-Qiang; Wang, Jian-Liang

    2013-11-01

    To investigate the causes and prevention of the complications about treatment of acromioclavicular joint dislocation (Tossy III) and unstable distal clavicular fracture (Neer II) with clavicular hook plate. From January 2001 to December 2011, 246 patients with acromioclavicular joint dislocation (Tossy III) and 222 patients with unstable distal clavicular fracture (Neer II) were treated with acromioclvicular hook plate fixation,including 348 males and 120 females with an average age of 45.4 years old ranging from 21 to 80 years old. The mean time from injury to operation was 30.8 hours (ranged from 1 h to 15 d). All patients had normal shoulder function before injury. According to Karlsson evaluation standard, the cases with excellent and good function of the shoulder joint were regarded as the normal group, and the cases with poor function of shoulder joint as the abnormal group. The comparison of the range of forward flexion,backward stretch, adduction, abduction and elevation of shoulder joints between two groups was performed. The data of impingement, subacromial osteolysis, acromioclavicular arthritis, clavicular stress fracture, downward acromioclavicular joint subluxation, hook cut-out and hook break were summarized. All patients were followed up from 8 to 48 months with an average of 12.5 months. The results were excellent in 308 cases,good in 76,and poor in 84 according to Karlsson evaluation. The excellent and good rate was 82.1%. The difference of the range of forward flexion, backward stretch, adduction, abduction and elevation of shoulder joints between two groups had a statistically significant difference (P acromioclavicular arthritis or painful shoulder caused by delayed dirigation,7 (1.50%) with clavicular stress fracture or interal plate upward, 6 (1.28%) with downward acromioclavicular joint subluxation, 5 (1.07%) with hook cut -out and 3 (0.64%) in hook break. The clavicular hook plate is useful for the treatment of acromioclavicular joint

  9. MINIMAL INVASIVE PLATE OSTEOSYNTHESIS- AN EFFECTIVE TREATMENT METHOD FOR DISTAL TIBIA INTRAARTICULAR (PILON FRACTURES- AN 18 MONTHS FOLLOW UP

    Directory of Open Access Journals (Sweden)

    Saket Jati

    2016-12-01

    Full Text Available BACKGROUND Tibial pilon fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable, because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and Minimally Invasive Plate Osteosynthesis (MIPO for distal tibia has emerged as an alternative treatment option because it respects fracture biology and haematoma and also provides biomechanically stable construct. The aim of the study is to evaluate the results of minimally invasive plate osteosynthesis using locking plates in treating tibial pilon fractures in terms of fracture union, restoration of ankle function and complications. MATERIALS AND METHODS 30 patients with closed tibial pilon fractures (Ruedi and Allgower type I (14, type II (13, type III (3 treated with MIPO with Locking Compression Plates (LCP were prospectively followed for average duration of 18 months. RESULTS Average duration of injury-hospital and injury-surgery interval was as 12.05 hrs. and 3.50 days, respectively. All fractures got united with an average duration of 20.8 weeks (range 14-28 weeks. Olerud and Molander score was used for evaluation at 3 months, 6 months and 18 months. One patient had union with valgus angulation of 15 degrees, but no nonunion was found. CONCLUSION The present study shows that MIPO with LCP is an effective treatment method in terms of union time and complications rate for tibial pilon fracture promoting early union and early weight bearing.

  10. [Curative efficacies of mini-invasive percutaneous osteosynthesis versus supercutaneous plating for distal tibial fractures].

    Science.gov (United States)

    He, Xianfeng; Zhu, Limei; Zhang, Jingwei; Li, Ming; Yu, Yihui

    2014-12-30

    To compare the clinical efficacies of mini-invasive percutaneous osteosynthesis (MIPO) versus supercutaneous plating with closed reduction in the treatment of distal tibial fractures. A total of 48 patients with close distal tibial fractures were treated between January 2010 and January 2012. The MIPO group included 16 males and 8 females with an average age of 36 years. And the types were A (n = 15), B (n = 6) and C (n = 3) according to the classification scheme of Association for the Study of Internal Fixation (AO/ASIF). The supercutaneous plating group also included 16 males and 8 females with an average age of 37 years. And the types were A (n = 15), B (n = 6) and C (n = 3). And the operative duration, hospital stay, union time, postoperative complications and function of ankle were compared between two groups. The mean follow-up period was 18.5 (12-26) months. There was no instance of nonunion, hardware breakdown or deep infection. Patients in supercutaneous plating group had significantly shorter mean operative duration, hospital stay and union time. Three patients and 1 patient in MIPO group presented with superficial infection and delayed union respectively while there was no occurrence in supercutaneous plating group. And the differences were not statistically significant. Fifteen patients (62.5%) complained of implant impingement or discomfort. And stripping occurred at an incidence of 15.6% during the removal time of locking screws in MIPO group. While in supercutaneous plating group, there as no complaint of skin irritation and removal of supercutaneous plate was easily performed without anesthesia. The mean AOFAS score was 90.7 ± 3.8 in supercutaneous plating group versus 88.9 ± 4.1 in MIPO group (P = 0.070). Distal tibia fractures may be treated successfully with MIPO or supercutaneous plating. However, supercutaneous plating offers multiple advantages in terms of mean operative duration, hospital stay, union time, skin irritation and implant

  11. Accelerated rehabilitation compared with a standard protocol after distal radial fractures treated with volar open reduction and internal fixation: a prospective, randomized, controlled study.

    Science.gov (United States)

    Brehmer, Jess L; Husband, Jeffrey B

    2014-10-01

    There are relatively few studies in the literature that specifically evaluate accelerated rehabilitation protocols for distal radial fractures treated with open reduction and internal fixation (ORIF). The purpose of this study was to compare the early postoperative outcomes (at zero to twelve weeks postoperatively) of patients enrolled in an accelerated rehabilitation protocol with those of patients enrolled in a standard rehabilitation protocol following ORIF for a distal radial fracture. We hypothesized that patients with accelerated rehabilitation after volar ORIF for a distal radial fracture would have an earlier return to function compared with patients who followed a standard protocol. From November 2007 to November 2010, eighty-one patients with an unstable distal radial fracture were prospectively randomized to follow either an accelerated or a standard rehabilitation protocol after undergoing ORIF with a volar plate for a distal radial fracture. Both groups began with gentle active range of motion at three to five days postoperatively. At two weeks, the accelerated group initiated wrist/forearm passive range of motion and strengthening exercises, whereas the standard group initiated passive range of motion and strengthening at six weeks postoperatively. Patients were assessed at three to five days, two weeks, three weeks, four weeks, six weeks, eight weeks, twelve weeks, and six months postoperatively. Outcomes included Disabilities of the Arm, Shoulder and Hand (DASH) scores (primary outcome) and measurements of wrist flexion/extension, supination, pronation, grip strength, and palmar pinch. The patients in the accelerated group had better mobility, strength, and DASH scores at the early postoperative time points (zero to eight weeks postoperatively) compared with the patients in the standard rehabilitation group. The difference between the groups was both clinically relevant and statistically significant. Patients who follow an accelerated rehabilitation

  12. A position statement of the Traumatology Society of Slovenia on the treatment of fragility fractures of the pelvic ring

    Directory of Open Access Journals (Sweden)

    Drago Brilej

    2016-11-01

    Full Text Available Because of the ageing crisis in western world the fragility fractures of the pelvic ring joint the big four group of typical fractures in osteoporotic elderly patients: fractures of the proximal femur, fractures of the proximal humerus, fractures of the distal radius and thoracic and lumbar low energy spinal fractures. All these fractures are the result of low energy with the typical fall of the patient from the standing height. The Slovenian recommendations include Rommens classification for non-displaced and displaced fractures of the anterial and posterial pelvic ring with the operative indications. The recommendations were launched at the Slovenian society of trauma surgeons meeting in November 7th, 2015.

  13. [Growth behaviour after fractures of the proximal radius: differences to the rest of the skeleton].

    Science.gov (United States)

    Hell, A K; von Laer, L

    2014-12-01

    Fractures of the proximal end of the radius in the growth phase have three characteristics: the head of the radius articulates with two joint partners and is therefore indispensable for an undisturbed function of the elbow. The blood supply of the proximal end of the radius is via periosteal vessels in the sense of a terminal circulation which makes it extremely vulnerable. Severe trauma caused either by accidents or treatment, can result in partial or complete necrosis with deformity of the head and neck region of the radius. Radioulnar synostosis and chronic epiphysiolysis are irreversible complications which can occur after excessive physiotherapy. Despite a low potency growth plate, in young patients the proximal end of the radius shows an enormous spontaneous correction of dislocations. Side to side shifts, however, will not be remodeled. Therapy should be as atraumatic as possible. Due to the blood supply situation, with the appropriate indications the spontaneous correction and a brief period of immobilization without physiotherapy should be integrated into the therapy concept. If an operation is necessary, repeated traumatic repositioning maneuvers should be avoided and in case of doubt closed or careful open repositioning can be achieved with intramedullary nailing. In order to take the special characteristics of the proximal radius into consideration, the vulnerability and correction potential must be weighed up against each other. Therapy must be as atraumatic as possible. The spontaneous correction potential should be integrated into the primary therapy without overestimating this potential with respect to the extent and age of the patient.

  14. [Locked plating with minimally invasive percutaneous plate osteosynthesis versus intramedullary nailing of distal extra-articular tibial fracture: a retrospective study].

    Science.gov (United States)

    Yao, Qi; Ni, Jie; Peng, Li-bin; Yu, Da-xin; Yuan, Xiao-ming

    2013-12-17

    To compare the efficacies of minimally invasive plate osteosynthesis (MIPPO) and interlocking intramedullary nailing (IMN) in the treatment of extra-articular fractures of distal tibia. Retrospective reviews were conducted for 126 patients with extra-articular distal tibia fractures. Treatment was either MIPPO (n = 61) or IMN (n = 65). The outcomes were assessed by comparing operating duration, time to union, the last follow-up American Orthopedic Foot and Ankle Society (AOFAS) score and complication rate. The average follow-up period was 23.7 (12-53) months. In the minimally invasive plate osteosynthesis group, there were deep infections (n = 2), superficial infections (n = 5), delayed union (n = 2), malunion (n = 2) and knee joint pain (n = 10) were observed. In addition, the average operating duration (85.9 ± 18.9 min), average time to union (17.3 ± 3.8 weeks) and average AOFAS (83.2 ± 11.9) were analyzed. In the interlocking intramedullary nailing group, there were delayed union (n = 3), malunion (n = 12) and knee joint pain (n = 22). And the average operating duration (83.3 ± 15.7 min), average time to union (16.5 ± 3.1 weeks) and average AOFAS (84.9 ± 12.0) were analyzed. No statistical significance existed in operating duration, time to union and the last follow-up AOFAS between two groups (P > 0.05). However, the rates of malformation and knee joint pain were higher in the intramedullary nail group than those in the plate group. And the difference was statistically significant (P = 0.015, P = 0.025). Both MIPPO and IMN are effective for extra-articular fractures of distal tibia. However, the former has the advantage of lowers rate of malformation and knee joint pain. Therefore a surgeon should consider the degree of injury while managing extra-articular fracture of distal tibia.

  15. Preliminary experience with biodegradable implants for fracture fixation

    Directory of Open Access Journals (Sweden)

    Dhillon Mandeep

    2008-01-01

    Full Text Available Background: Biodegradable implants were designed to overcome the disadvantages of metal-based internal fixation devices. Although they have been in use for four decades internationally, many surgeons in India continue to be skeptical about the mechanical strength of biodegradable implants, hence this study. Materials and Methods: A prospective study was done to assess the feasibility and surgeon confidence level with biodegradable implants over a 12-month period in an Indian hospital. Fifteen fractures (intra-articular, metaphyseal or small bone fractures were fixed with biodegradable implants. The surgeries were randomly scheduled so that different surgeons with different levels of experience could use the implants for fixation. Results: Three fractures (one humeral condyle, two capitulum, were supplemented by additional K-wires fixation. Trans-articular fixator was applied in two distal radius and two pilon fractures where bio-pins alone were used. All fractures united, but in two cases the fracture displaced partially during the healing phase; one fibula due to early walking, and one radius was deemed unstable even after bio-pin and external fixator. Conclusions: Biodegradable -implants are excellent for carefully selected cases of intra-articular fractures and some small bone fractures. However, limitations for use in long bone fractures persist and no great advantage is gained if a "hybrid" composite is employed. The mechanical properties of biopins and screws in isolation are perceived to be inferior to those of conventional metal implants, leading to low confidence levels regarding the stability of reduced fractures; these implants should be used predominantly in fracture patterns in which internal fixation is subjected to minimal stress.

  16. Triceps-sparing approach for open reduction and internal fixation of neglected displaced supracondylar and distal humeral fractures in children.

    Science.gov (United States)

    Rizk, Ahmed Shawkat

    2015-06-01

    Supracondylar humeral fractures are one of the most common skeletal injuries in children. In cases of displacement and instability, the standard procedure is early closed reduction and percutaneous Kirschner wire fixation. However, between 10 and 20 % of patients present late. According to the literature, patients with neglected fractures are those patients who presented for treatment after 14 days of injury. The delay is either due to lack of medical facilities or social and financial constraints. The neglected cases are often closed injuries with no vascular compromise. However, the elbow may still be tense and swollen with abrasions or crusts. In neglected cases, especially after early appearance of callus, there is no place for closed reduction and percutaneous pinning. Traditionally, distal humeral fractures have been managed with surgical approaches that disrupt the extensor mechanism with less satisfactory functional outcome due to triceps weakness and elbow stiffness. The aim of this study is to evaluate the outcome of delayed open reduction using the triceps-sparing approach and Kirschner wire fixation for treatment of neglected, displaced supracondylar and distal humeral fractures in children. This prospective study included 15 children who had neglected displaced supracondylar and distal humeral fractures. All patients were completely evaluated clinically and radiologically before intervention, after surgery and during the follow-up. The follow-up period ranged from 8 to 49 months, with a mean period of 17 months. Functional outcome was evaluated according to the Mayo Elbow Performance Index (MEPI) and Mark functional criteria. All fractures united in a mean duration of 7.2 weeks (range 5-10 weeks) with no secondary displacement or mal-union. Excellent results were found at the last follow-up in 13 of the 15 patients studied (86.66 %), while good results were found in two patients (13.33 %) according to the MEPI scale. According to the Mark

  17. Two-wave propagation in in vitro swine distal ulna

    Science.gov (United States)

    Mano, Isao; Horii, Kaoru; Matsukawa, Mami; Otani, Takahiko

    2015-07-01

    Ultrasonic transmitted waves were obtained in an in vitro swine distal ulna specimen, which mimics a human distal radius, that consists of interconnected cortical bone and cancellous bone. The transmitted waveforms appeared similar to the fast waves, slow waves, and overlapping fast and slow waves measured in the specimen after removing the surface cortical bone (only cancellous bone). In addition, the circumferential waves in the cortical bone and water did not affect the fast and slow waves. This suggests that the fast-and-slow-wave phenomenon can be observed in an in vivo human distal radius.

  18. Treatment of distal tibial fractures: plate versus nail: a retrospective outcome analysis of matched pairs of patients.

    NARCIS (Netherlands)

    Janssen, K.W.; Biert, J.; Kampen, A. van

    2007-01-01

    A study of 24 patients who sustained an extra-articular fracture of the distal third of the tibial shaft was performed to determine the effect of the type of treatment, open reduction and internal fixation (ORIF) or closed reduction and intramedullary (IM) nailing, on the occurrence of malalignment.

  19. Is intramedullary nailing applicable for distal tibial fractures with ankle joint extension?

    Science.gov (United States)

    Beytemür, Ozan; Albay, Cem; Adanır, Oktay; Yüksel, Serdar; Güleç, Mehmet Akif

    2016-12-01

    This study aims to evaluate the functional and radiographic results and treatment complications of AO/OTA (Arbeitsgemeinschaft fur Osteosynthesefragen/Orthopaedic Trauma Association) type 43C1 and C2 fractures treated with intramedullary nailing. We retrospectively evaluated 35 AO/OTA type 43C1 and C2 patients (26 males, 9 females; mean age 39.8±16.9 years; range 19 to 82 years) treated with intramedullary nailing. Two interfragmentary screws out of nail were applied in 10 patients (29%), while one interfragmentary screw out of nail was applied in 17 patients (49%). Intramedullary nailing was applied in eight patients (23%) without external screws. Fracture union, union time, alignment problems, and complications were evaluated. Clinical evaluation of patients was conducted using the Olerud and Molander score and by measuring the ankle joint range of motion. Union was achieved in all 35 patients. Mean union time was 16.5±2.8 weeks (range 12 to 24 weeks) and mean Olerud and Molander score was 88±8.24. Varus deformity was detected in one patient, valgus deformity was detected in two patients, and rotation deformity was detected in one patient. Superficial infection was detected in three patients (9%). Deep infection was not detected in any patient. Intramedullary nailing is not contraindicated for simple intra-articular distal tibial fractures. In these fractures, intramedullary nailing performed in accordance with its technique, with an additional percutaneous screw if necessary, is a successful treatment option with high fracture union rates, high functional results, and low complication rates.

  20. A randomized controlled trial of cast versus splint for distal radial buckle fracture: an evaluation of satisfaction, convenience, and preference.

    Science.gov (United States)

    Williams, Kristine G; Smith, Gillian; Luhmann, Scott J; Mao, Jingnan; Gunn, Joseph D; Luhmann, Janet D

    2013-05-01

    Buckle fractures are inherently stable and at low risk for displacement. These advantages allow for treatment options that may create confusion for the practitioner. Accepted immobilization methods include circumferential cast, plaster or prefabricated splint, and soft bandaging. Despite mounting evidence for splinting, the questions of pain, preference, satisfaction, and convenience offer a challenge to changing practice. The purposes of this study were (1) to compare cast versus splint for distal radial buckle fractures in terms of parental and patient satisfaction, convenience, and preference and (2) to compare pain reported for cast versus splint. We conducted a prospective randomized trial of a convenience sample of patients 2 through 17 years with a radiologically confirmed distal radial buckle fracture. Subjects were randomly assigned to short-arm cast or prefabricated wrist splint. We assessed satisfaction, convenience, preference, and pain in the emergency department and at days 1, 3, 7, and 21 after immobilization. Ninety-four patients were enrolled. Compared with the cast group, those in the splint group reported higher levels of satisfaction, preference, and convenience on 10-point visual analog scale. Although pain scores were higher for those in the splint group, the difference was not statistically significant. With the exception of pain reported in the emergency department being higher for the splinted group, all other measures, including convenience, satisfaction, and preference, showed a clear trend favoring splints at almost every time period in the study. This study provides additional evidence that splinting is preferable to casting for the treatment of distal radial buckle fractures.

  1. A Prospective Randomized Study on Operative Treatment for Simple Distal Tibial Fractures-Minimally Invasive Plate Osteosynthesis Versus Minimal Open Reduction and Internal Fixation.

    Science.gov (United States)

    Kim, Ji Wan; Kim, Hyun Uk; Oh, Chang-Wug; Kim, Joon-Woo; Park, Ki Chul

    2018-01-01

    To compare the radiologic and clinical results of minimally invasive plate osteosynthesis (MIPO) and minimal open reduction and internal fixation (ORIF) for simple distal tibial fractures. Randomized prospective study. Three level 1 trauma centers. Fifty-eight patients with simple and distal tibial fractures were randomized into a MIPO group (treatment with MIPO; n = 29) or a minimal group (treatment with minimal ORIF; n = 29). These numbers were designed to define the rate of soft tissue complication; therefore, validation of superiority in union time or determination of differences in rates of delayed union was limited in this study. Simple distal tibial fractures treated with MIPO or minimal ORIF. The clinical outcome measurements included operative time, radiation exposure time, and soft tissue complications. To evaluate a patient's function, the American Orthopedic Foot and Ankle Society ankle score (AOFAS) was used. Radiologic measurements included fracture alignment, delayed union, and union time. All patients acquired bone union without any secondary intervention. The mean union time was 17.4 weeks and 16.3 weeks in the MIPO and minimal groups, respectively. There was 1 case of delayed union and 1 case of superficial infection in each group. The radiation exposure time was shorter in the minimal group than in the MIPO group. Coronal angulation showed a difference between both groups. The American Orthopedic Foot and Ankle Society ankle scores were 86.0 and 86.7 in the MIPO and minimal groups, respectively. Minimal ORIF resulted in similar outcomes, with no increased rate of soft tissue problems compared to MIPO. Both MIPO and minimal ORIF have high union rates and good functional outcomes for simple distal tibial fractures. Minimal ORIF did not result in increased rates of infection and wound dehiscence. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  2. Effective management of bone fractures with the IlluminOss® photodynamic bone stabilization system: initial clinical experience from the European Union registry

    Directory of Open Access Journals (Sweden)

    Thomas Gausepohl

    2017-02-01

    Full Text Available The IlluminOss® system (IS uses a light-curable polymer contained within an inflatable balloon catheter, forming a patient customized intramedullary implant. A registry was established in Germany and The Netherlands to prospectively collect technical and clinical outcomes in patients treated with IS for fractures of the phalange, metacarpal, radius, ulna, distal radius, fibula, clavicle and/or olecranon. Humeral, femoral, tibial and pelvic fractures were included under compassionate use. Procedural success included successful placement of the device at the target fracture site and achievement of fracture stabilization. Clinical and radiographic assessments were made postoperatively through 12 months. One hundred thirty two patients (149 fractures were enrolled with most fractures (85% resulting from low-energy trauma. Simple fractures predominated (47% followed by complex (23% and wedge (16% fractures. Procedural success was achieved in all patients and no implants required removal or revision. Normal range of motion was realized in 87% of fractures. Radiographically, there was substantial cortical bridging, total dissolution of the fracture line, and complete fracture healing. Across a variety of fracture types, the IS provides a safe and effective approach for rapid healing and functional recovery.

  3. [Effectiveness comparison of flexible fixation and rigid fixation in treatment of ankle pronation-external rotation fractures with distal tibiofibular syndesmosis].

    Science.gov (United States)

    Li, Yuewei; Zhang, Minghui; Li, Xiaorong; Chen, Xiaoyong; Deng, Jianlong

    2017-07-01

    To compare the effectiveness of flexible fixation and rigid fixation in the treatment of ankle pronation-external rotation fractures with distal tibiofibular syndesmosis. A retrospective analysis was made on the clinical data of 50 patients with ankle pronation-external rotation fractures and distal tibiofibular syndesmosis treated between January 2013 and December 2015. Suture-button fixation was used in 23 patients (flexible fixation group) and cortical screw fixation in 27 patients (rigid fixation group). There was no significant difference in age, gender, weight, side, fracture type, and time from trauma to surgery between 2 groups ( P >0.05). The operation time, medial clear space (MCS), tibiofibular clear space (TFCS), tibiofibular overlap (TFO), American Orthopaedic Foot and Ankle Society (AOFAS) score, and Foot and Ankle Disability Index (FADI) score were compared between 2 groups. The operation time was (83.0±9.1) minutes in the flexible fixation group and was (79.6±13.1) minutes in the rigid fixation group, showing no significant difference ( t =1.052, P =0.265). All patients achieved healing of incision by first intention. The patients were followed up 12-20 months (mean, 14 months). The X-ray films showed good healing of fracture in 2 groups. There was no screw fracture, delayed union or nounion. The fracture healing time was (12.1±2.5) months in the flexible fixation group and was (11.3±3.2) months in the rigid fixation group, showing no significant difference between 2 groups ( t =1.024, P =0.192). Reduction loss occurred after removal of screw in 2 cases of the rigid fixation group. At last follow-up, there was no significant difference in MCS, TFCS, TFO, AOFAS score and FADI score between 2 groups ( P >0.05). Suture-button fixation has similar effectiveness to screw fixation in ankle function and imaging findings, and flexible fixation has lower risk of reduction loss of distal tibiofibular syndesmosis than rigid fixation.

  4. Comminuted fracture of the accessory carpal bone removed via an arthroscopic-assisted arthrotomy

    Science.gov (United States)

    Bonilla, Alvaro G.; Santschi, Elizabeth M.

    2015-01-01

    A 16-year-old American paint horse gelding was presented for evaluation of a left forelimb lameness grade III/V. Radiographs and computed tomography revealed a comminuted fracture of the accessory carpal bone involving the entire articulation with the distal radius and the proximal aspect of the articulation with the ulnar carpal bone. Multiple fragments were present in the palmar pouch of the antebrachiocarpal joint. An arthroscopic-assisted open approach was necessary to remove all fractured fragments. Subsequently the horse was re-admitted for lameness and was treated successfully with antibiotics and long-term supportive bandaging. PMID:25694665

  5. Comminuted fracture of the accessory carpal bone removed via an arthroscopic-assisted arthrotomy.

    Science.gov (United States)

    Bonilla, Alvaro G; Santschi, Elizabeth M

    2015-02-01

    A 16-year-old American paint horse gelding was presented for evaluation of a left forelimb lameness grade III/V. Radiographs and computed tomography revealed a comminuted fracture of the accessory carpal bone involving the entire articulation with the distal radius and the proximal aspect of the articulation with the ulnar carpal bone. Multiple fragments were present in the palmar pouch of the antebrachiocarpal joint. An arthroscopic-assisted open approach was necessary to remove all fractured fragments. Subsequently the horse was re-admitted for lameness and was treated successfully with antibiotics and long-term supportive bandaging.

  6. Reconstruction of lower end of radius using vascularized upper end of fibula

    Directory of Open Access Journals (Sweden)

    Koul Ashok

    2007-01-01

    Full Text Available Background: Giant cell tumor is a fairly common locally invasive tumor in young adults. The lower end of the radius is the second commonest site for this tumor. The most common treatment for this tumor is curettage with or without bone grafting but it carries a significant rate of recurrence. Excision is the treatment of choice, especially for cases in which the cortex has been breached. After excision of the distal end of the radius, different procedures have been described to reconstruct the defect of distal radius. These include partial arthrodesis and hemiarthroplasty using the upper end of the fibula. The upper end of the fibula has a morphological resemblance to the lower end of the radius and has been used to replace the latter. Traditionally it was used as a ′free′ (non-vascularized graft. More recently the upper end of the fibula has been transferred as a vascularized transfer for the same purpose. Though vascularized transfer should be expected to be more physiological, its superiority over the technically simpler non-vascularized transfer has not been conclusively proven. Materials and Methods: Two patients are presented who had giant cell tumor of distal radius. They underwent wide local excision and reconstruction with free vascularized upper end of the fibula. Result: Follow-up period was two and a half years and 12 months respectively. Both patients have returned to routine work. One patient has excellent functional result and the other has a good result. Conclusion: Vascularized upper end of fibula transfer is a reliable method of reconstruction for loss of the distal end of the radius that restores local anatomy and physiology.

  7. Fratura distal do rádio em pacientes com mais de 60 anos: placas ortogonais versus placa volar Distal radial fractures in patients over 60 years old: orthogonal plates versus volar plate

    Directory of Open Access Journals (Sweden)

    Edgard Novaes de França Bisneto

    2010-01-01

    Full Text Available OBJETIVO: Comparar os resultados do tratamento cirúrgico entre placa volar com estabilidade angular e placas ortogonais em fraturas instáveis de rádio distal em pacientes com mais de 60 anos. MÉTODOS: Pacientes foram divididos em dois grupos tratados com placa volar ou placas ortogonais. Resultados clínicos e radiográficos foram analisados prospectivamente. RESULTADOS: Os grupos de estudo apresentaram resultados clínicos e radiográficos semelhantes seis meses após a operação. No entanto três meses após a cirurgia, o grupo onde foi utilizada a placa volar obteve resultados superiores. CONCLUSÃO: Ambos os grupos apresentaram bons resultados funcionais. O tratamento cirúrgico facilita a reabilitação precoce. A técnica das placas ortogonais requer uma curva de aprendizado maior e apresentou mais complicações e piores resultados iniciais.OBJECTIVE: To compare the results from surgical treatment between volar plates with angular stability and orthogonal plates of unstable distal radius fractures in patients aged over 60 years. METHODS: Selected patients were randomized in two groups treated with volar plates or orthogonal plates. Clinic al and radiographic results were analyzed prospectively. RESULTS: The study groups presented similar clinical and radiographic results six months after the operation. However three months after surgery the volar plate group obtained superior results considering most of the parameters studied. CONCLUSION: Both the volar plates and the orthogonal plates presented good functional results. Surgical treatment enabled early rehabilitation for these patients. Orthogonal plate technique required a longer learning curve, presented more complications and worst early results.

  8. "Floating arm" injury in a child with fractures of the proximal and distal parts of the humerus: a case report

    Directory of Open Access Journals (Sweden)

    Güven Melih

    2009-09-01

    Full Text Available Abstract Introduction Simultaneous supracondylar humerus fracture and ipsilateral fracture of the proximal humerus in children is rare. Case presentation A 10-year-old Turkish boy with an extension type supracondylar humerus fracture and ipsilateral fracture at the proximal metaphyseal-diaphyseal junction of the humerus was treated by closed reduction and percutaneous Kirschner wire fixation. Closed reduction was performed using a Kirschner wire as a "joystick" to manipulate the humeral shaft after some swelling occurred around the elbow and shoulder. Conclusion The combination of fractures at the proximal and distal parts of the humerus can be termed as "floating arm" injury. Initial treatment of this unusual injury should be focused on the supracondylar humerus fracture. However, closed reduction can be difficult to perform with the swelling around the elbow and shoulder. A temporary Kirschner wire can be used as a "joystick" to fix and reduce the fracture.

  9. Evaluation of Outcomes of Open Reduction and Internal Fixation Surgery in Patients with Type C Distal Humeral Fractures

    Directory of Open Access Journals (Sweden)

    Mohammadhadi Nouraei

    2018-01-01

    Full Text Available Background: In this study, functional state of patients with Type C distal humerus fractures undergone surgical plating was evaluated 6 and 12 months after the surgery in order to record postsurgical factors such as pain level and job/performance satisfaction. Materials and Methods: In this cross-sectional study, 46 patients with humerus fractures were recruited and their ability to do daily tasks, presence of degenerative changes, stability of elbow joint, and range of motion was evaluated. For assessment of response to surgery, Mayo score was used. Results: Among 46 patients, 45 (97.8% of them had joint stability. Evaluation of postsurgical complications showed that six subjects (13% had no complications, but superficial infection was observed in 12 (26.1% subjects. Neuromuscular disorders in ulnar nerve were present in 11 subjects (23.9%, recurrent articular bursitis of elbow joint in 6 subjects (13%, stiffness of elbow joint in 29 subjects (63%, nonunion of fracture in 3 subjects (6.5%, and myositis ossification in 4 (8.7% subjects. Furthermore, 18 (39.1% patients presented with more than one (2–4 complications. Conclusion: Open reduction and internal fixation surgery with dual plating is the method of choice for treatment of Type C distal humeral fractures. Evaluation of long-term outcomes of this surgery could be done via several different questionnaires as many studies suggest. This study demonstrated that the outcomes of this surgery in Isfahan, Iran, have been noticeably inferior compared to results of the studies in other parts of the world.

  10. Transfixation pinning and casting of radial-ulnar fractures in calves: A review of three cases.

    Science.gov (United States)

    St-Jean, G; Debowes, R M

    1992-04-01

    We reviewed the medical records of three calves with radial-ulnar fractures which were reduced and stabilized by transfixation pinning and casting. Multiple Steinmann pins were placed transversely through proximal and distal fracture fragments and the pin ends were incorporated in fiberglass cast material after fracture reduction. Cast material was placed from proximal to distal radius and served as an external frame to maintain pin position and fracture reduction.At the time of injury, the calves ranged in age from one day to two months and weighed from 37-102 kg. Two fractures were comminuted and one was transverse. All fractures were closed. After surgery, all calves could walk within 24 hours. Radiographic and clinical evidence of fracture healing was present five to seven weeks (mean 6) after surgery. At that time, the pins and cast material were removed. Return to normal function was rapid and judged to be excellent at follow-up evaluation five to nine months later.Advantages of transfixation pinning and casting in management of radial-ulnar fractures include flexibility in pin positioning, adequate maintenance of reduction, early return to weight-bearing status, preservation of joint mobility, and ease of ambulation. The inability to adjust fixation and alignment after cast application is a disadvantage of this technique compared with other external fixators. We concluded that transfixation pinning is a useful means of stabilizing radial-ulnar fractures in pediatric bovine patients.

  11. Bone density of the radius, spine, and proximal femur in osteoporosis

    International Nuclear Information System (INIS)

    Mazess, R.B.; Barden, H.; Ettinger, M.; Schultz, E.

    1988-01-01

    Bone mineral density (BMD) was measured in 140 normal young women (aged 20 to 39 years) and in 423 consecutive women over age 40 referred for evaluation of osteoporosis. Lumbar spine and proximal femur BMD was measured using dual-photon absorptiometry ( 153 Gd), whereas the radius shaft measurement used single-photon absorptiometry ( 125 I). There were 324 older women with no fractures, of which 278 aged 60 to 80 years served as age-matched controls. There were 99 women with fractures including 32 with vertebral and 22 with hip fractures. Subsequently, another 25 women with hip fractures had BMD measured in another laboratory; their mean BMD was within 2% of that of the original series. The mean age in both the nonfracture and fracture groups was 70 +/- 5 years. The BMD in the age-matched controls was 20% to 25% below that of normal young women for the radius, spine, and femur, but the Ward's triangle region of the femur showed even greater loss (35%). The mean BMD at all sites in the crush fracture cases was about 10% to 15% below that of age-matched controls. Spinal abnormality was best discriminated by spine and femoral measurements (Z score about 0.9). In women with hip fractures, the BMD was 10% below that of age-matched controls for the radius and the spine, and the BMD for the femoral sites was about 25% to 30% below that of age-matched control (Z score about 1.6). Femoral densities gave the best discrimination of hip fracture cases and even reflected spinal osteopenia. In contrast, neither the spine nor the radius reflected the full extent of femoral osteopenia in hip fracture

  12. Fechamento epifisário da extremidade distal do rádio de eqüinos da raça Brasileira de Hipismo (BH Distal radius physeal closure in the Brasileiro de Hipismo horse breed (BH

    Directory of Open Access Journals (Sweden)

    Carmen Lice Buchmann de Godoy

    2004-12-01

    Full Text Available Com o objetivo de avaliar a idade de fechamento epifisário da raça Brasileira de Hipismo (BH, um grupo de 24 cavalos, 12 machos inteiros e 12 fêmeas, teve a região epifisária da extremidade distal do rádio radiografada, mês a mês, em projeção crânio-caudal, a partir dos 18 meses de idade até o fechamento completo. Os dados do experimento foram analisados pelo método ANOVA de uma via, utilizando-se o teste "t" de Student para comparação entre as médias. Concluiu-se que o fechamento epifisário completo ocorreu aos 25,83 ± 1,58 meses nas fêmeas e aos 28,16 ± 1,40 meses nos machos (pTwenty-four Brasileiro de Hipismo horses (BH, 12 intact males and 12 females, were used in this study to determine the closure time of the distal radial physis. Craniocaudal radiographs of the distal radius were taken at 18 months of age and until the fusion of the physis. Data were analysed by One-way ANOVA and Student t-test to compare means between groups. The closure time of the distal radial physis occurred at 25.83 ± 1.58 months of age in females and 28.16 ± 1.40 months in males (p<0.001.

  13. Fractures of the distal clavicle: comparison between two surgical treatment methods

    Directory of Open Access Journals (Sweden)

    José Carlos Souza Vilela

    2015-04-01

    Full Text Available OBJECTIVE: To compare the clinical and radiographic results from osteosynthesis of fractures of the lateral third of the clavicle, using two methods: T plates or anchors together with Kirschner wires.METHODS: Fifteen patients of mean age 34.3 years (range: 19-57 and mean follow-up 22.7 months (range: 14-32 were evaluated. In nine cases, a T plate was used; and in six cases, coracoclavicular fixation was used with anchors in the coracoid process and Kirschner wires through the acromioclavicular joint. The evaluation included the Constant score, personal satisfaction and radiographic assessment.RESULTS: Both types of treatment achieved consolidation in all cases. Group 1 presented a higher Constant score (83.4 than that of Group 2 (76.4 (p = 0.029. Neither of the techniques presented any severe complications, and mild complications were only observed in Group 2 (80%, mostly consisting of migration of the Kirschner wire and superficial infection.CONCLUSION: Surgical treatment of fractures of the distal clavicle using T plates provided the same consolidation rate as shown by coracoclavicular fixation with anchors in the coracoid process and Kirschner wires through the acromioclavicular joint, and better clinical results.LEVEL OF EVIDENCE: Level III evidence was obtained. Comparative retrospective study and therapeutic study were performed.

  14. Intra-articular Physeal Fractures of the Distal Femur: A Frequently Missed Diagnosis in Adolescent Athletes.

    Science.gov (United States)

    Pennock, Andrew T; Ellis, Henry B; Willimon, Samuel C; Wyatt, Charles; Broida, Samuel E; Dennis, M Morgan; Bastrom, Tracey

    2017-10-01

    Intra-articular physeal fractures of the distal femur are an uncommon injury pattern, with only a few small case series reported in the literature. To pool patients from 3 high-volume pediatric centers to better understand this injury pattern, to determine outcomes of surgical treatment, and to assess risk factors for complications. Case series; Level of evidence, 4. A multicenter retrospective review of all patients presenting with an intra-articular physeal fracture between 2006 and 2016 was performed. Patient demographic and injury data, surgical data, and postoperative outcomes were documented. Radiographs were evaluated for fracture classification (Salter-Harris), location, and displacement. Differences between patients with and without complications were compared by use of analysis of variance or chi-square tests. A total of 49 patients, with a mean age of 13.5 years (range, 7-17 years), met the inclusion criteria. The majority of fractures were Salter-Harris type III fractures (84%) involving the medial femoral condyle (88%). Football was responsible for 50% of the injuries. The initial diagnosis was missed in 39% of cases, and advanced imaging showed greater mean displacement (6 mm) compared with radiographs (3 mm). All patients underwent surgery and returned to sport with "good to excellent" results after 2 years. Complications were more common in patients with wide-open growth plates, patients with fractures involving the lateral femoral condyle, and patients who were casted ( P < .05). Clinicians evaluating skeletally immature athletes (particularly football players) with acute knee injuries should maintain a high index of suspicion for an intra-articular physeal fracture. These fractures are frequently missed, and advanced imaging may be required to establish the diagnosis. Leg-length discrepancies and angular deformities are not uncommon, and patients should be monitored closely. Surgical outcomes are good when fractures are identified, with high rates

  15. Coracoclavicular ligament reconstruction with the autogenous anterior half of the peroneus longus tendon for distal clavicle fracture (Neer type Ⅱ-b: A report of 26 cases

    Directory of Open Access Journals (Sweden)

    Guang-you YANG

    2017-12-01

    Full Text Available Objective To explore the clinical effect of coracoclavicular ligament reconstruction with the autogenous anterior half of peroneus longus tendon (AHPLT for distal clavicle fracture (Neer type Ⅱ-b. Methods The clinical data were retrospectively analyzed of 26 Neer type Ⅱ-b distal clavicle fracture surgically treated by coracoclavicular ligament reconstruction with autogenous AHPLT in Ganyu District People's Hospital of Lianyungang from June 2012 to May 2015. Among the 26 cases, 16 males and 10 females, aged from 19-56 years (average 38.7 years. Fracture occurred in left side in 18 cases and in right side in 8 cases. Postoperative observations were done on fracture healing, shoulder and ankle-foot function recovery. Results For all the 26 cases, surgical incisions were healed well, and no infection, vascular and peroneal nerve injury and iatrogenic fracture occurred. Follow-up was carried out for 10-24 months with average of 15.3 months. All the fractures were healed within 12-20 weeks with an average of 14.6 weeks. One patient was found of losing the fracture reduction part during the follow-up process, and then got eventual healing by extending the limb brake time. Another patient was found of slight tendon sensation disorder with no significant effect on daily life and exercise, and the symptoms disappeared 6 months later. At the last follow-up, the Constant-Murley score was 92-100 with an average of 97.8 points. The ankle-hind foot score of American Society of Ankle and Orthopedics was excellent. Conclusion Reconstruction of coracoclavicular ligament with autogenous AHPLT is an effective treatment for Neer type Ⅱ-b distal clavicle fracture with good safety and without negative effect on the ankle-foot function, and thus it is worthy of wider clinical use. DOI: 10.11855/j.issn.0577-7402.2017.12.12

  16. Distal Oblique Bundle Reinforcement for Treatment of DRUJ Instability.

    Science.gov (United States)

    Brink, Peter R G; Hannemann, Pascal F W

    2015-08-01

    Background Chronic, dynamic bidirectional instability in the distal radioulnar joint (DRUJ) is diagnosed clinically, based on the patient's complaints and the finding of abnormal laxity in the vicinity of the distal ulna. In cases where malunion is ruled out or treated and there are no signs of osteoarthritis, stabilization of the DRUJ may offer relief. To this end, several different techniques have been investigated over the past 90 years. Materials and Methods In this article we outline the procedure for a new technique using a tendon graft to reinforce the distal edge of the interosseous membrane. Description of Technique A percutaneous technique is used to harvest the palmaris longus tendon and to create a tunnel, just proximal to the sigmoid notch, through the ulna and radius in an oblique direction. By overdrilling the radial cortex, the knotted tendon can be pulled through the radius and ulna and the knot blocked at the second radial cortex, creating a strong connection between the radius and ulna at the site of the distal oblique bundle (DOB). The tendon is fixed in the ulna with a small interference screw in full supination, preventing subluxation of the ulna out of the sigmoid notch during rotation. Results Fourteen patients were treated with this novel technique between 2011 and October 2013. The QuickDASH score at 25 months postoperatively (range 16-38 months) showed an improvement of 32 points. Similarly, an improvement of 33 points (67-34 months) was found on the PRWHE. Only one recurrence of chronic, dynamic bidirectional instability in the DRUJ was observed. Conclusion This simple percutaneous tenodesis technique between radius and ulna at the position of the distal edge of the interosseous membrane shows promise in terms of both restoring stability and relieving complaints related to chronic subluxation in the DRUJ.

  17. [Z-osteotomy of distal fibula to correct widened ankle mortice after fracture].

    Science.gov (United States)

    Tao, Xu; Tang, Kanglai; Zhou, Jianbo

    2012-07-01

    To analyse the clinical outcomes of the Z-osteotomy of the distal fibula to correct widened mortice of the ankle after fracture. Between September 2009 and February 2011, 5 patients (5 feet) with widened ankle mortice after fracture underwent Z-osteotomy. There were 4 males and 1 female, aged from 23 to 58 years (mean, 38 years). At 3 months after operation of internal fixation when function exercises were done, patients got pains. The interval between trauma and operation ranged from 5 to 36 months (mean, 13.2 months). Lateral pressure test showed positive in 2 cases and negative in 3 cases. American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot score was 50.2 +/- 17.3. Primary healing of incision was achieved in all cases. Five patients were followed up 9 to 24 months (mean, 15.6 months). Mild to moderate swelling of the affected limb and anterolateral skin numbness of the ipsilateral dorsal foot occurred, and gradually improved. The clinical exam and radiology showed bone union at 12-15 weeks (mean, 13.5 weeks). Postoperative range of motion of ankle had no significant improvement. AOFAS ankle-hindfoot scores were 76.8 +/- 11.2 at 6 months after operation, and 85.4 +/- 3.2 at last follow-up, showing significant differences when compared with preoperative score (P ankle mortice after fracture; Z-osteotomy can effectively reduce the width of the ankle mortice, increase the stability of ankle joint, and decrease the complication rate.

  18. Clinical and non-clinical aspects of distal radioulnar joint instability

    NARCIS (Netherlands)

    Wijffels, M.; Brink, P.R.G.; Schipper, I.

    2012-01-01

    Untreated distal radioulnar joint (DRUJ) injuries can give rise to long lasting complaints. Although common, diagnosis and treatment of DRUJ injuries remains a challenge. The articulating anatomy of the distal radius and ulna, among others, enables an extensive range of forearm pronosupination

  19. Ilizarov external fixation versus plate osteosynthesis in the management of extra-articular fractures of the distal tibia.

    Science.gov (United States)

    Fadel, Mohamed; Ahmed, Mohamed Ali; Al-Dars, Ahmed Mounir; Maabed, Mustafa Ahmed; Shawki, Hashem

    2015-03-01

    The purpose of this study was to evaluate the outcome of Ilizarov external fixation (IE) versus dynamic compression plate (PO) in the management of extra-articular distal tibial fractures. Between 2010 and 2011, extra-articular distal tibial fractures in 40 consecutive patients met the inclusion criteria. They were classified according to AO classification fracture type A (A1, A2, and A3). In a randomized method, two equal groups were managed using either IE or PO. PO was performed using open reduction and internal fixation (ORIF) and DCP through anterolateral approach. IE was done using Ilizarov frame. For the PO group, non-weight bearing ambulation was permitted on the second postoperative day but partial weight bearing was permitted according to the progression in union criteria clinically and radiologically. For the IE group, weight bearing started as tolerated from the first postoperative day. Physiotherapy and pin-site care was performed by the patient themselves. Modified Mazur ankle score was applied to IE (excellent 10, good 10) and in PO (excellent 2, good 8, poor 6). Data were statically analysed using (Mann-Whitney test). The rate of healing in the IE group (average 130) was higher than the PO (average 196.5); plus, there were no cases of delayed union or nonunion in the IE group (p value 0.003). It was found that IE compared with PO provides provision of immediate weight bearing as tolerated following postoperative recovery, irrespective of radiological or clinical healing with no infection, deformity or non-union.

  20. [Application of three-dimensional printing in the operation of distal tibia fracture involving epiphyseal plate injury for teenagers].

    Science.gov (United States)

    Zhao, Jingxin; Ma, Yachang; Han, Dong; Jin, Yu

    2017-10-01

    To investigate the application value of three-dimensional (3-D) printing technology in the operation of distal tibia fracture involving epiphyseal plate injury for teenagers. The retrospective analysis was conducted on the clinical data of 16 cases of children patients with distal tibia fracture involving epiphyseal plate injury undergoing the operation by using of 3-D printing technology between January 2014 and December 2015. There were 12 males and 4 females with an age of 9-14 years (mean, 12.8 years). The causes of injury included traffic accident injury in 9 cases, heavy pound injury in 3 cases, and sport injury in 4 cases. The time from injury to operation was 3-92 hours (mean, 25.8 hours). According to Salter-Harris typing standard, the typing for epiphyseal injury was classified as type Ⅱ in 11 cases, type Ⅲ in 4 cases, and type Ⅳ in 1 case. The thin slice CT scan on the affected limb was performed before operation, and the Mimics14.0 medical software was applied for the design and the 1∶1 fracture model was printed by the 3-D printer; the stimulation of operative reduction was made in the fracture model, and bone plate, Kirschner wire, and hollow screw with the appropriate size were chosen, then the complete operative approach and method were designed and the internal fixator regimen was chosen, then the practical operation was performed based on the preoperative design regimen. The operation time was 40-68 minutes (mean, 59.1 minutes); the intraoperative blood loss was 5-102 mL (mean, 35 mL); the intraoperative fluoroscopy times was 2-6 times (mean, 2.8 times). All the patiens were followed up 12-24 months (mean, 15 months). The fracture of 15 cases reached anatomic reduction, and 1 cases had no anatomic reduction with the displaced end less than 1 mm. All the fractures reached bony union with the healing time of 2-4 months (mean, 2.6 months). There was no deep vein thrombosis, premature epiphyseal closure and oblique, or uneven ankle surface

  1. Magnetic resonance imaging-detected adaptation and pathology in the distal condyles of the third metacarpus, associated with lateral condylar fracture in Thoroughbred racehorses.

    Science.gov (United States)

    Tranquille, C A; Parkin, T D H; Murray, R C

    2012-11-01

    Lateral condylar (LC) fractures of the third metacarpus (McIII) are a common reason for euthanasia in racehorses, and may be the result of repetitive overloading or cumulative pathological change. Magnetic resonance imaging (MRI) allows monitoring of bone and cartilage to detect pathological and adaptive changes that may be precursors of fracture. To describe bone and cartilage MRI features in the distal condyles of McIII of Thoroughbred racehorses, with and without condylar fracture. 1) A greater degree of bone and cartilage adaptation or pathology will be seen in fractured McIIIs compared with their respective contralateral McIIIs. 2) Contralateral McIIIs will have a greater degree of bone and cartilage adaptation or pathology than McIIIs from control horses that did not sustain a LC fracture. The McIIIs from 96 horses subjected to euthanasia at racecourses were divided into 3 groups: Group 1: nonfractured bones from horses without LC fracture; Group 2: nonfractured bones from horses with unilateral LC fracture; and Group 3: fractured bones from horses with unilateral LC fracture. The MR images were examined and graded for bone and cartilage changes. Nine percent of Group 1 (n = 9) and 11% of Group 2 bones (n = 5) had incomplete LC fractures. Focal palmar necrosis was most frequently detected in bones from Group 1 (12%) compared with Groups 2 (9%) and 3 (4%). The prevalence of bone and/or cartilage abnormalities tended to increase from Group 1 to Group 2 to Group 3. Magnetic resonance imaging is able to detect cartilage and bone changes that may be associated with LC fracture. There was no significant difference in bone/cartilage changes between bones from Groups 1 and 2, despite increased pathology in Group 2 bones. Periodic monitoring of bone and/or cartilage changes in distal McIII of Thoroughbred racehorses may help to prevent catastrophic LC fractures. © 2012 EVJ Ltd.

  2. Does osteoporosis increase complication risk in surgical fracture treatment? A protocol combining new endpoints for two prospective multicentre open cohort studies

    Directory of Open Access Journals (Sweden)

    Marent Marta

    2010-11-01

    Full Text Available Abstract Background With an ever-increasing elderly population, orthopaedic surgeons are faced with treating a high number of fragility fractures. Biomechanical tests have demonstrated the potential role of osteoporosis in the increased risk of fracture fixation complications, yet this has not been sufficiently proven in clinical practice. Based on this knowledge, two clinical studies were designed to investigate the influence of local bone quality on the occurrence of complications in elderly patients with distal radius and proximal humerus fractures treated by open reduction and internal fixation. Methods/Design The studies were planned using a prospective multicentre open cohort design and included patients between 50 and 90 years of age. Distal radius and proximal humerus fractures were treated with locking compression 2.4 mm and proximal humerus internal locking plates, respectively. Follow-up examinations were planned for 6 weeks, 3 and 12 months as well as a telephone interview at 6 months. The primary outcome focuses on the occurrence of at least one local bone quality related complication. Local bone quality is determined by measuring bone mineral density and bone mineral content at the contralateral radius. Primary complications are categorised according to predefined factors directly related to the bone/fracture or the implant/surgical technique. Secondary outcomes include the documentation of soft tissue/wound or general/systemic complications, clinical assessment of range of motion, and patient-rated evaluations of upper limb function and quality of life using both objective and subjective measures. Discussion The prospective multicentre open cohort studies will determine the value of local bone quality as measured by bone mineral density and content, and compare the quality of local bone of patients who experience a complication (cases following surgery with that of patients who do not (controls. These measurements are novel and

  3. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists.

    Science.gov (United States)

    Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M

    2016-01-01

    To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = radiography (P radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run.

  4. Intra-articular osteotomy for distal humerus malunion

    NARCIS (Netherlands)

    Marti, René K.; Doornberg, Job

    2009-01-01

    Intra-articular osteotomy is considered in the rare case of malunion after a fracture of the distal humerus to restore humeral alignment and gain a functional arc of elbow motion. Traumatic and iatrogenic disruption of the limited blood flow to the distal end of the humerus resulting in avascular

  5. Assessment of pisotriquetral misalignment with magnetic resonance imaging: Is it associated with trauma?

    Energy Technology Data Exchange (ETDEWEB)

    Chae, Hee-Dong; Yoo, Hye Jin; Hong, Sung Hwan; Choi, Ja-Young [Seoul National University Hospital, Department of Radiology, Seoul National University College of Medicine, Jongno-Gu, Seoul (Korea, Republic of); Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-City, Gyeongi-Do (Korea, Republic of)

    2017-07-15

    Our objective was to determine whether there is an association between pisotriquetral (PT) malalignment and acute distal radius fracture by using magnetic resonance imaging (MRI). We evaluated 138 patients who underwent 3-T MRI of the wrists. Group A comprised 85 patients with acute distal radius fracture, and group B comprised 53 patients without trauma. PT interval and angle and pisiform excursion were measured on oblique axial and sagittal multiplanar reformats. The presence of abnormalities in the flexor carpi ulnaris tendon (FCU), pisometacarpal ligament (PML), and pisohamate ligament (PHL) were evaluated. PT interval was wider in group A on both the axial and sagittal planes (P < 0.001). Axial PT angle opened more radially in group A (P < 0.001), and the absolute value of the sagittal PT angle in group A was wider than that in group B (P = 0.006). Abnormalities in FCU, PML, and PHL were more frequently observed in group A (P < 0.001). On multiple linear regression, distal radius fracture remained significant after adjusting for the patient's age and PT osteoarthritis. Acute distal radius fracture can affect normal alignment of the PT joint, resulting in associated injuries to the primary PT joint stabilizers. (orig.)

  6. Influence of side-groove root radius on the ductile fracture toughness of miniature C(T) specimens

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; Scibetta, M.

    2009-05-15

    The use of miniature C(T) specimens, MC(T), for fracture toughness measurements in the upper shelf regime has been investigated at SCK-CEN since 2004, in the framework of the Electrabel/Tractebel SCK-CEN Convention (now General Framework Agreement SUEZ-SCK-CEN). This geometry has been used and validated on both unirradiated (2004-05) and irradiated (2006) materials, mainly reactor pressure vessel (RPV) steels. While side-grooved MC(T) specimens have shown in all conditions a systematically lower tearing resistance and ductile crack initiation toughness as compared to standard-size 1TC(T) samples, the only plain-sided MC(T) specimen tested in 2005 exhibited very high ductile fracture toughness, thus pointing at a strong influence of side-grooving on the upper shelf properties of MC(T) specimens. This study investigates the influence of side-grooving on the initiation toughness and tearing resistance of MC(T) specimens, as a function of the root radius of the side-groove (ranging from 0.1 to 1 mm) and in comparison with plain-sided MC(T) and reference 1TC(T) samples. The material used is the well characterized DIN 22NiMoCr37 RPV steel, which had been used in the European project which generated the famous EURO fracture toughness data set.

  7. Radiological evaluation of the skeleton: traumatology of the distal forearm, wrist, and hand; Radiologische Skelettdiagnostik: Traumatologie des distalen Unterarmes, der Handgelenke und der Hand

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, K. [Universitaetsklinikum Essen (Germany). Zentralinstitut fuer Roentgendiagnostik; Langer, R. [Universitaetsklinikum Essen (Germany). Zentralinstitut fuer Roentgendiagnostik

    1996-07-01

    Plain X-ray films including some special radiographic views are still the basis of the radiological evaluation of injuries of the distal forearm, the wrist, and the hand. Especially, in the diagnosis of fractures of the distal radius the exact positioning of the arm and hand is essential. For the description of fractures of the distal forearm the AO classification of fractures should be used, which is comprehensive and universally applicable. Conventional tomography and computed tomography (CT) of the radio-ulnar joint and the wrist are used in patients with persisting complaints or equivocal findings on plain radiographs, and difficult anatomical situations. Suspected ligamentous injuries of the wrist including tears of the triangular fibrocartilage complex (TFCC) are evaluated by wrist arthrography or magnetic resonance imaging (MRI), the latter requiring a highly skilled imaging and interpretation technique. MRI is the method of choice for the detection of osteonecrosis. Ultrasound examinations are of minor importance in the work up of wrist and hand injuries. (orig.) [Deutsch] Fuer die radiologische Beurteilung von Verletzungen des distalen Unterarmes, des Handgelenkes und der Hand steht die konventionelle Roentgenuntersuchung einschliesslich einiger Spezialeinstellungen nach wie vor im Vordergrund. Bei der Beschreibung insbesondere der distalen Radiusfrakturen sollten die historische Benennung oder aeltere Einteilungen zugunsten der allgemeingueltigen und umfassenderen AO-Klassifikation verlassen werden. Die Computertomographie und Magnetresonanztomographie kommen in der Frakturdiagnostik bei unklaren anatomischen Verhaeltnissen oder konventionell nicht zufriedenstellend erklaerbaren Beschwerden zur Anwendung. Vermutete ligamentaere Verletzungen der Handwurzel lassen sich arthrographisch oder magnetresonanztomographisch abklaeren. (orig.)

  8. First-line management of distal humerus fracture by total elbow arthroplasty in geriatric traumatology: Results in a 21-patient series at a minimum 2years' follow-up.

    Science.gov (United States)

    Lami, D; Chivot, M; Caubere, A; Galland, A; Argenson, J N

    2017-10-01

    Total elbow arthroplasty (TEA) is one option in distal humerus fracture in elderly osteoporotic patients. The study hypothesis was that, in patients aged 70years or more, TEA provides functional results and ranges of motion compatible with everyday activity, with a complications rate equal to or lower than with internal fixation, and no loss of autonomy or cognitive impairment. In this retrospective study, 21 patients receiving TEA for distal humerus fracture were included. Mean follow-up was 3.2years, with functional (Quick DASH and MEPS), cognitive (MMSE), autonomy-related (ADL) and radiological assessment (Morrey). Mean MEPS was 84 and QuickDASH 32.4. Mean extension deficit was 22°, and mean flexion 125°. There was no loss of autonomy or cognitive impairment. The complications rate was 9.5%. There were no revision surgeries. TEA proved reliable in comminuted distal humerus fracture in elderly patients. Functional results were comparable to those in the literature, and the complications rate was lower. Long-term implant survival needs confirmation to validate this option as a treatment of choice in these indications in geriatric traumatology. Retrospective non-comparative, single-center. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  9. Objective assessment of plaster cast quality in pediatric distal forearm fractures: Is there an optimal index?

    Science.gov (United States)

    Labronici, Pedro José; Ferreira, Leonardo Termis; Dos Santos Filho, Fernando Claudino; Pires, Robinson Esteves Santos; Gomes, Davi Coutinho Fonseca Fernandes; da Silva, Luiz Henrique Penteado; Gameiro, Vinicius Schott

    2017-02-01

    Several so-called casting indices are available for objective evaluation of plaster cast quality. The present study sought to investigate four of these indices (gap index, padding index, Canterbury index, and three-point index) as compared to a reference standard (cast index) for evaluation of plaster cast quality after closed reduction of pediatric displaced distal forearm fractures. Forty-three radiographs from patients with displaced distal forearm fractures requiring manipulation were reviewed. Accuracy, sensitivity, specificity, false-positive probability, false-negative probability, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were calculated for each of the tested indices. Comparison among indices revealed diagnostic agreement in only 4.7% of cases. The strongest correlation with the cast index was found for the gap index, with a Spearman correlation coefficient of 0.94. The gap index also displayed the best agreement with the cast index, with both indices yielding the same result in 79.1% of assessments. When seeking to assess plaster cast quality, the cast index and gap index should be calculated; if both indices agree, a decision on quality can be made. If the cast and gap indices disagree, the padding index can be calculated as a tiebreaker, and the decision based on the most frequent of the three results. Calculation of the three-point index and Canterbury index appears unnecessary. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. [Treatment of type C intercondylar fractures of distal humerus using dual plating].

    Science.gov (United States)

    Liu, Ya-Ke; Xu, Hua; Liu, Fan; Wang, You-Hua; Tao, Ran; Cao, Yi; Wang, Hong; Zhou, Zhen-Yu; Zhu, Yong

    2009-06-15

    To evaluate the clinical outcome of dual plating in the treatment of humeral intercondylar type-C fractures in adults. From June 2004 to October 2007, 38 cases of type-C distal humeral fractures were stabilised with dual plating. There were 21 males and 17 females. The average age was 43 years with a range from 21 to 71 years. According to the AO classification, 9 cases were of type C1, 17 of C2 and 12 of C3. The posterior midline approach was selected. Twenty-one cases were exposed through the trans-olecranon osteotomy, 11 through the Campbell (Van Gorder) approach, 6 through triceps sparing approach. Autogenous bone graft was performed in 5 cases because of severe comminution. Thirty-five patients were followed-up for 14-30 months (mean 24.2 months). At the latest follow-up, the elbow flexion averaged 119 degrees (range 90 degrees - 135 degrees ), and the loss of extension averaged 16.2 degrees (range 5 degrees - 25 degrees ). All the patients got bony healing, the average healing period was 14 weeks. The patients were evaluated using the criteria of Aitken and Rorabeek and the scores were 13 excellent, 16 good, 6 fair. Twenty-nine patients (82.9%) had a good or excellent results. Complications included 4 cases of traumatic osteoarthritis, 2 heterotopic ossification, 1 ulnar neuropathy. Infection as well as loosening or breakage of the implant was not found. The dual plating is able to provide rigid fixation for the humeral intercondylar fractures. In addition, it can allow early functional exercise after operation, decrease the related complications significantly, and improve the functional results.

  11. Prior ankle fractures in postmenopausal women are associated with low areal bone mineral density and bone microstructure alterations.

    Science.gov (United States)

    Biver, E; Durosier, C; Chevalley, T; Herrmann, F R; Ferrari, S; Rizzoli, R

    2015-08-01

    In a cross-sectional analysis in postmenopausal women, prior ankle fractures were associated with lower areal bone mineral density (BMD) and trabecular bone alterations compared to no fracture history. Compared to women with forearm fractures, microstructure alterations were of lower magnitude. These data suggest that ankle fractures are another manifestation of bone fragility. Whether ankle fractures represent fragility fractures associated with low areal bone mineral density (aBMD) and volumetric bone mineral density (vBMD) and/or bone microstructure alterations remains unclear, in contrast to the well-recognised association between forearm fractures and osteoporosis. The objective of this study was to investigate aBMD, vBMD and bone microstructure in postmenopausal women with prior ankle fracture in adulthood, compared with women without prior fracture or with women with prior forearm fractures, considered as typically of osteoporotic origin. In a cross-sectional analysis in the Geneva Retirees Cohort study, 63 women with ankle fracture and 59 with forearm fracture were compared to 433 women without fracture (mean age, 65 ± 1 years). aBMD was measured by dual-energy X-ray absorptiometry; distal radius and tibia vBMD and bone microstructure were measured by high-resolution peripheral quantitative computed tomography. Compared with women without fracture, those with ankle fractures had lower aBMD, radius vBMD (-7.9%), trabecular density (-10.7%), number (-7.3%) and thickness (-4.6%) and higher trabecular spacing (+14.5%) (P ankle fractures were 2.2 and 1.6, respectively, vs 2.2 and 2.7 for forearm fracture, respectively (P ≤ 0.001 for all). Compared to women with forearm fractures, those with ankle fractures had similar spine and hip aBMD, but microstructure alterations of lower magnitude. Women with ankle fractures have lower aBMD and vBMD and trabecular bone alterations, suggesting that ankle fractures are another manifestation of bone fragility.

  12. External fixation of tibial pilon fractures and fracture healing.

    Science.gov (United States)

    Ristiniemi, Jukka

    2007-06-01

    Distal tibial fractures are rare and difficult to treat because the bones are subcutaneous. External fixation is commonly used, but the method often results in delayed union. The aim of the present study was to find out the factors that affect fracture union in tibial pilon fractures. For this purpose, prospective data collection of tibial pilon fractures was carried out in 1998-2004, resulting in 159 fractures, of which 83 were treated with external fixation. Additionally, 23 open tibial fractures with significant > 3 cm bone defect that were treated with a staged method in 2000-2004 were retrospectively evaluated. The specific questions to be answered were: What are the risk factors for delayed union associated with two-ring hybrid external fixation? Does human recombinant BMP-7 accelerate healing? What is the role of temporary ankle-spanning external fixation? What is the healing potential of distal tibial bone loss treated with a staged method using antibiotic beads and subsequent autogenous cancellous grafting compared to other locations of the tibia? The following risk factors for delayed healing after external fixation were identified: post-reduction fracture gap of >3 mm and fixation of the associated fibula fracture. Fracture displacement could be better controlled with initial temporary external fixation than with early definitive fixation, but it had no significant effect on healing time, functional outcome or complication rate. Osteoinduction with rhBMP-7 was found to accelerate fracture healing and to shorten the sick leave. A staged method using antibiotic beads and subsequent autogenous cancellous grafting proved to be effective in the treatment of tibial bone loss. Healing potential of the bone loss in distal tibia was at least equally good as in other locations of the tibia.

  13. Intérêt de l’enclouage centromédullaire dans les fractures du quart distal de la jambe: à propos de 30 cas

    Science.gov (United States)

    Margad, Omar; Boukhris, Jalal; Sallahi, Hicham; Azriouil, Ouahb; Daoudi, Mohamed; Koulali, Khalid

    2017-01-01

    Les fractures du quart distal de la jambe, sont des fractures dont le trait est situé au niveau du quart inférieur du tibia. Elles sont réputées graves et posent à la fois des problèmes de consolidation, de contention et de stabilité. Nous présentons l'expérience du service de traumatologie orthopédie de l'Hôpital militaire Avicenne de Marrakech, concernant 30 fractures fermées du quart inférieur de la jambe, sur une période de 10 ans (de Janvier 2001 à Décembre 2010) ayant reçu un enclouage centromédullaire. Le montage était verrouillé à 80% des cas et simple dans les autres cas. La moyenne d'âge de nos patients était de 36 ans. Il existait une nette prédominance masculine avec 27 hommes pour 3 femmes. La consolidation a été obtenue dans un délai normal de 17 semaines en moyenne et les résultats fonctionnels était satisfaisants. Un seul cas d'infection est survenu à 6 mois du geste chirurgical soit 3,3% et aucune autre complication n'a été mentionnée. Un cal vicieux a été retrouvé chez 30% de nos patients. Nos données épidémiologiques et nos résultats sont presque identiques à ceux de la littérature. Quant aux résultats angulaires, ils sont nettement inférieurs aux séries de plaques, à l'opposé, leurs résultats infectieux portent à la prudence et certains séries de clous rapportent d'excellents résultats angulaires à condition d'avoir un montage stable. A la lumière de ces résultats, nous sommes en droit de conclure au grand intérêt d'élargir les indications classiques de l'enclouage centromédullaire verrouillé à la prise en charge des fractures du quart distal de la jambe, à condition d'avoir un montage stable par un double verrouillage distal et une ostéosynthèse primaire des fractures distales de la fibula. PMID:29541322

  14. Percutaneous treatment of insufficiency fractures. Principles, technique and review of literature

    International Nuclear Information System (INIS)

    Beall, Douglas P.; Datir, Abhijit; D'Souza, Sharon L.; D'Souza, Logan S.; Gunda, Divya; Morelli, John; Johnson, Michael Brandon; Nabavizadeh, Nima

    2010-01-01

    Insufficiency fractures of the pelvis, sacrum, spine, and long bones are painful, debilitating, and are common consequences of osteoporosis. Conventional treatment for these fractures varies from conservative therapy to surgery with plate and screw fixation. The former fails to address the underlying problem of fracture and frequently does not alleviate symptoms, while the latter is invasive and not always possible in older populations with low bone density and numerous co-morbidities. Osseous augmentation with polymethylmethacrylate (PMMA) has been used for over two decades to treat fractures related to osteoporosis, but has not been commonly used to treat fractures outside of the vertebral bodies. Osseous augmentation with PMMA is an image-guided procedure and various techniques have been utilized to treat fracture in different locations. We describe various techniques for image-guided osseous augmentation and treatment of insufficiency fractures with bothPMMA and allograft bone for fractures of the pelvis including sacrum, acetabulum, pubic symphysis, pubic rami ilium; appendicular skeleton including distal radius, proximal femur, and vertebral body. We also describe the potential risks and complications associated with percutaneous treatment of insufficiency fractures and techniques to avoid the pitfalls of the various procedures. We will present the process for patient follow-up and data regarding the pre- and postprocedure pain response in patients undergoing treatment for pelvic insufficiency fractures. (orig.)

  15. A randomised prospective study of two different combined internal and external fixation techniques for distal tibia shaft fractures.

    Science.gov (United States)

    Sun, Liao-Jun; Yu, Xian-Bin; Dai, Cheng-Qian; Hu, Wei; Guo, Xiao-Shan; Chen, Hua

    2014-12-01

    External fixation combined with limited open reduction and internal fixation (EF + LORIF) is a well-accepted and effective method for distal tibia shaft fractures, but it was also related to complications. The objective of this study was to compare external fixation combined with closed reduction and internal fixation (EF + CRIF) with EF + LORIF in the treatment of distal tibia shaft fractures, and explore the benefits and defects of these two techniques. Fifty-six patients were randomised to operative stabilisation either by an external fixator combined with two closed titanium elastic nails or by external fixation combined with limited open reduction and internal fixation. Pre-operative variables included the patients’ age, sex, the affected side, cause of injury, Tscherne classification of soft tissue injury, fracture pattern, and time from injury to surgery. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems and other complications, union time, time of recovery to work, the functional American Orthopaedic Foot and Ankle surgery (AOFAS) score. There was no significant difference in the mean operating time (72.6 ± 11.5 vs. 78.5 ± 16.4 min, P = 0.125), the time to union (21.2 ± 11.0 vs. 22.5 ± 12.3 weeks, P = 0.678), the time of recovery to work (25.0 ± 14.5 vs. 26.4 ± 13.6 weeks, P = 0.711), pin track infection (3/28 vs. 4/28, P = 1.000), delayed union (2/28 vs. 3/28, P = 1.000), pain (38.3 ± 1.6 vs. 38.7 ± 1.5, P = 0.339), function (44.4 ± 6.0 vs. 45.0 ± 5.5, P = 0.698), and total AOFAS scores (91.5 ± 7.4 vs. 93.4 ± 6.8, P = 0.322) between the two groups. However, the mean radiation time was longer in the EF + CRIF group than in the EF + LORIF group (2.0 ± 1.2 vs. 0.3 ± 0.1 min, P alignment was obtained in 50 patients (22 in EF + CRIF vs. 28 in EF + LORIF, P = 0.023). Two cases with EF + CRIF had a 6 degrees of recurvatum deformity and four had 6–9 degrees of valgus deformity

  16. Intra-Articular Osteotomy for Distal Humerus Malunion

    Directory of Open Access Journals (Sweden)

    René K. Marti

    2009-01-01

    Full Text Available Intra-articular osteotomy is considered in the rare case of malunion after a fracture of the distal humerus to restore humeral alignment and gain a functional arc of elbow motion. Traumatic and iatrogenic disruption of the limited blood flow to the distal end of the humerus resulting in avascular necrosis of capitellum or trochlea is a major pitfall of the this technically challenging procedure. Two cases are presented which illustrate the potential problems of intra-articular osteotomy for malunion of the distal humerus.

  17. A prospective, randomised trial comparing closed intramedullary nailing with percutaneous plating in the treatment of distal metaphyseal fractures of the tibia.

    Science.gov (United States)

    Guo, J J; Tang, N; Yang, H L; Tang, T S

    2010-07-01

    We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study. A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients' age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware. We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p fractures had united. Patients who had intramedullary nailing had a higher mean pain score (40 = no pain, 0 = severe pain), [corrected] but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed. We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with

  18. Ankle fractures have features of an osteoporotic fracture.

    Science.gov (United States)

    Lee, K M; Chung, C Y; Kwon, S S; Won, S H; Lee, S Y; Chung, M K; Park, M S

    2013-11-01

    We report the bone attenuation of ankle joint measured on computed tomography (CT) and the cause of injury in patients with ankle fractures. The results showed age- and gender-dependent low bone attenuation and low-energy trauma in elderly females, which suggest the osteoporotic features of ankle fractures. This study was performed to investigate the osteoporotic features of ankle fracture in terms of bone attenuation and cause of injury. One hundred ninety-four patients (mean age 51.0 years, standard deviation 15.8 years; 98 males and 96 females) with ankle fracture were included. All patients underwent CT examination, and causes of injury (high/low-energy trauma) were recorded. Mean bone attenuations of the talus, medial malleolus, lateral malleolus, and distal tibial metaphysis were measured on CT images. Patients were divided into younger age (fractures than the younger age group. With increasing age, bone attenuations tended to decrease and the difference of bone attenuation between the genders tended to increase in the talus, medial malleolus, lateral malleolus, and distal tibial metaphysis. Ankle fracture had features of osteoporotic fracture that is characterized by age- and gender-dependent low bone attenuation. Ankle fracture should not be excluded from the clinical and research interest as well as from the benefit of osteoporosis management.

  19. [Intramedullary nailing of the distal tibia illustrated with the Expert(TM) tibia nail].

    Science.gov (United States)

    El Attal, R; Hansen, M; Rosenberger, R; Smekal, V; Rommens, P M; Blauth, M

    2011-12-01

    Restoration of axis, length, and rotation of the lower leg. Sufficient primary stability of the osteosynthesis for functional aftercare and to maintain joint mobility. Good bony healing in closed and open fractures. Closed and open fractures of the tibia and complete lower leg fractures distal to the isthmus (AO 42), extraarticular fractures of the distal tibia (AO 43 A1/A2/A3), segmental fractures of the tibia with a fracture in the distal tibia, and certain intraarticular fractures of the distal tibia without impression of the joint line with the use of additional implants (AO 43 C1) Patient in reduced general condition (e.g., bed ridden), flexion of the knee of less than 90°, patients with knee arthroplasty of the affected leg, infection in the area of the nail's insertion, infection of the tibial cavity, complex articular fractures of the proximal or distal tibia with joint depression. Closed reduction of the fracture preferably on a fracture table or using a distractor or an external fixation frame. If necessary, use pointed reduction clamps or sterile drapery. In some cases, additional implants like percutaneous small fragment screws, poller screws or k-wires are helpful. Open reduction is rarely necessary and must be avoided. Opening of the proximal tibia in line with the medullary canal. Canulated insertion of the Expert(TM) tibia nail (ETN; Synthes GmbH, Oberdorf, Switzerland) with reaming of the medullary canal. Control of axis, length, and rotation. Distal interlocking with the radiolucent drill and proximal interlocking with the targeting device. Immediate mobilization of ankle and knee joint. Mobilization with 20 kg weight-bearing with crutches. X-ray control 6 weeks postoperatively and increased weight-bearing depending on the fracture status. In cases with simple fractures, good bony contact, or transverse fracture pattern, full weight-bearing at the end of week 6 is targeted. Between July 2004 and May 2005, 180 patients were included in a

  20. A clinical study evaluating bone mineral mass in the radius during skeletal growth

    International Nuclear Information System (INIS)

    Hagino, Hiroshi

    1989-01-01

    Using 125-I single photon absorptiometry, bone mineral measurements were performed on 206 healthy Japanese children (2 to 19 years of age). Bone mineral content (BMC), bone width (BW) and BMC/BW values were determined for the radius at distal 1/6 site (metaphysis) and distal 1/3 site (diaphysis). BMC/BW values at both sites correlated well with body height and weight. Bone mass in the diaphysis (distal 1/3 site) increased linearly during the 2-19 years of skeletal growth, but bone mass in the metaphysis (1/6 site) increased steeply during the pubertal period. In children receiving glucocorticoid therapy, bone mass was reduced in proportion to the duration of drug administration. In children under anticonvulsant therapy, the yearly increse in bone mass was significantly low especially in those patients with poor physical activity levels. Bone mineral decrease in the radius occurred in the children with hypopituitalism, hypothyroidism (cretinism), hyperthyroidism and Turner's syndrome. (author)

  1. [Comparative study of less invasive stabilization system (LISS) and the condylar support plates for the treatment of AO type C distal femoral fractures in adults].

    Science.gov (United States)

    Chen, Yu-tao; Yang, Jiang-wei; Hou, Hai-bin; Wang, Chun-sheng; Wang, Kun-zheng

    2015-02-01

    To summarize the complications and the early clinical effect of less invasive stabilization system and the femoral condylar support plates in the treatment of AO type C distal femoral fractures. From September 2007 to February 2012, 46 patients with AO type C distal femoral fractures were retrospectively studied. Of all patients 25 were treated with less invasive stabilization system including 14 males and 11 females with a mean age of (56.3±4.2) years old; according to AO classification, there were 14 cases of C1, 8 cases of C2 and 3 cases of C3 with a mean hospital stay of (15.6±1.7) days. While 21 cases were treated with femoral condylar support plates fixation including 12 males and 9 females with a mean age of (53.8±5.1) years old;there were 13 cases of C1, 6 cases of C2 and 2 cases of C3 with a mean hospital stay of (17.8±2.2) days. Comparative analysis was performed from the operation related index,postoperative complications and Evanich score of the knee joint function between the two groups at follow-up. All 46 patients were followed up from 13 to 38 months with a mean time of 19.6 months after surgery. Complications included 1 case with infection,3 cases with internal fixation failure, 1 case with nonunion and 1 case with activity limitation of the affected knee. The differences in the incision length, blood loss, fracture healing time were significant between two groups (P0.05). The statistical significance was also found in the Evanich score at last follow-up between two groups (Pfracture healing time and better functional recovery. Less invasive stabilization system had became one of the ideal internal fixations in the treatment of AO type C distal femoral fractures.

  2. Are the patient-rated wrist evaluation (PRWE) and the disabilities of the arm, shoulder and hand (DASH) questionnaire used in distal radial fractures truly valid and reliable?

    Science.gov (United States)

    Krol, R. G.; Bhandari, M.; Goslings, J. C.; Poolman, R. W.; Scholtes, V. A. B.

    2018-01-01

    Objectives The patient-rated wrist evaluation (PRWE) and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire are patient-reported outcome measures (PROMs) used for clinical and research purposes. Methodological high-quality clinimetric studies that determine the measurement properties of these PROMs when used in patients with a distal radial fracture are lacking. This study aimed to validate the PRWE and DASH in Dutch patients with a displaced distal radial fracture (DRF). Methods The intraclass correlation coefficient (ICC) was used for test-retest reliability, between PROMs completed twice with a two-week interval at six to eight months after DRF. Internal consistency was determined using Cronbach’s α for the dimensions found in the factor analysis. The measurement error was expressed by the smallest detectable change (SDC). A semi-structured interview was conducted between eight and 12 weeks after DRF to assess the content validity. Results A total of 119 patients (mean age 58 years (sd 15)), 74% female, completed PROMs at a mean time of six months (sd 1) post-fracture. One overall meaningful dimension was found for the PRWE and the DASH. Internal consistency was excellent for both PROMs (Cronbach’s α 0.96 (PRWE) and 0.97 (DASH)). Test-retest reliability was good for the PRWE (ICC 0.87) and excellent for the DASH (ICC 0.91). The SDC was 20 for the PRWE and 14 for the DASH. No floor or ceiling effects were found. The content validity was good for both questionnaires. Conclusion The PRWE and DASH are valid and reliable PROMs in assessing function and disability in Dutch patients with a displaced DRF. However, due to the high SDC, the PRWE and DASH are less useful for individual patients with a distal radial fracture in clinical practice. Cite this article: Y. V. Kleinlugtenbelt, R. G. Krol, M. Bhandari, J. C. Goslings, R. W. Poolman, V. A. B. Scholtes. Are the patient-rated wrist evaluation (PRWE) and the disabilities of the arm, shoulder and

  3. Giant cells tumor of radius distal end and bone reconstruction

    International Nuclear Information System (INIS)

    La O Duran, Eldis; Monzon Fernandez, Abel Nicolas; Sanz Delgado, Licett

    2009-01-01

    This is the case of a black women aged 40 presenting with a tumor of distal end of right radium with histological diagnosis of low-grade malignancy giant cells tumor and proposal of limb amputation. A conservative surgery was performed with a two-steps total exeresis of lesion sparing the oncologic margin. A fibular free-graft was used and wrist arthrodesis and internal fixation of graft using AO system. There was a good graft consolidation and an active incorporation of patient to social activities. The diagnosis, treatment, follow-up, rehabilitation and case prognosis are exposed

  4. ULNAR NEURITIS ASSOCIATED WITH GUN STOCK DEFORMITY FOLLOWING SUPRACONDYLAR FRACTURE OF HUMERUS

    Directory of Open Access Journals (Sweden)

    Sunita Morhan

    2014-04-01

    Full Text Available Background: This case report describes a patient who was referred to physiotherapist from a hand surgeon. Among the fractures around the elbow joint, radial head fracture and fracture of distal end of radius are common among adults. The occurrence of Supracondylar fractures are more commonly seen in children when compared to adults. One of the complications of this fracture is malunion resulting in Gun stock deformity. The main Purpose of this case report is to explore, 1. The complication associated with gunstock deformity 2. Chances of iatrogenic nerve injury after manipulation under anesthesia. 3.Long term supervised rehabilitation approach. Case Description: A 40 years old male patient referred to our Physiotherapy department by a hand surgeon. After the initial evaluation, findings revealed limitation in right elbow movement and tingling and numbness sensation in little and half of ring fingers in his right side. This patient underwent ulnar nerve transposition surgery followed by rehabilitation. His physiotherapy session includes electrotherapeutic agents for pain relief, passive mobilization of elbow and strengthening program for his flexors and extensors of elbow for a period of one year. Outcome: The outcome of the long term rehabilitation approach for a patient with ulnar neuropathy secondary to gunstock deformity after ulnar nerve transposition surgery is good. The patients tingling and numbness decreased and the range of elbow movement improved significantly. Discussion: Most common complications of fracture of distal end of humerus include malunion,ischemic contracture and nerve injuries. The relative incidence of iatrogenic nerve injuries associatedwith this fracture has been reported as being 2%-6%. Nerve injuries after Supracondylar humeral fractures occur primarily due to tenting or entrapment of the nerve on the sharp proximal humeral fragment, while iatrogenic injuries occur either during closed manipulation or percutaneous

  5. Distal humeral physeal injuries in child abuse: MR imaging and ultrasonography findings

    International Nuclear Information System (INIS)

    Nimkin, K.; Kleinman, P.K.; Teeger, S.; Spevak, M.R.

    1995-01-01

    Distal humeral physeal injuries, in particular, fracture-separation of the distal humeral epiphysis, can be seen in abused infants. Detection of physeal injury in an infant of toddler may indicate the possibility of unsuspected abuse, particularly when an appropriate history explaining the circumstance of the fracture is lacking. In addition, the extent of injury can be difficult to characterize on plain radiographs. Ultrasonography (US) and MR imaging (MRI) may be of value in diagnosis and may obviate the need for intraoperative arthrography. We present MRI findings in three abused children with distal humeral physeal injuries. Sonographic correlation is also presented in one case. (orig.)

  6. Distal humeral physeal injuries in child abuse: MR imaging and ultrasonography findings

    Energy Technology Data Exchange (ETDEWEB)

    Nimkin, K. [Dept. of Radiology, Univ. of Massachusetts, Medical Center, Worcester, MA (United States); Kleinman, P.K. [Dept. of Radiology, Univ. of Massachusetts, Medical Center, Worcester, MA (United States); Teeger, S. [Dept. of Radiology, Univ. of Massachusetts, Medical Center, Worcester, MA (United States); Spevak, M.R. [Dept. of Radiology, Univ. of Massachusetts, Medical Center, Worcester, MA (United States)

    1995-09-01

    Distal humeral physeal injuries, in particular, fracture-separation of the distal humeral epiphysis, can be seen in abused infants. Detection of physeal injury in an infant of toddler may indicate the possibility of unsuspected abuse, particularly when an appropriate history explaining the circumstance of the fracture is lacking. In addition, the extent of injury can be difficult to characterize on plain radiographs. Ultrasonography (US) and MR imaging (MRI) may be of value in diagnosis and may obviate the need for intraoperative arthrography. We present MRI findings in three abused children with distal humeral physeal injuries. Sonographic correlation is also presented in one case. (orig.)

  7. OUTCOME OF LOCKING PLATES IN DISTAL TIBIA FRACTURES TREATMENT

    OpenAIRE

    Lokesh; Dayanand; Deepak; Hemanth

    2016-01-01

    INTRODUCTION Most of these fractures except intra-articular fractures are treated with interlocking nail. 1,2 These nails are a boon for these fractures. But as the fracture nears to the joint stability the fracture fixation will be compromised due to malreduction and alignment, it leads to increased chances of delayed and nonunion. 3 Locking anatomical plates are evaluated for anatomical and relative stability fixation. Since then most intra and near intra-articul...

  8. Management and outcome of fractures of the distal phalanx: a retrospective study of 285 horses with a long term outcome in 223 cases.

    Science.gov (United States)

    Rijkenhuizen, Astrid B M; de Graaf, Kim; Hak, Annelieke; Fürst, Anton; ter Braake, Frerik; Stanek, Christian; Greet, Tim R C

    2012-05-01

    A multicentre study of 285 cases was performed to enhance the management of distal phalangeal fractures on the basis of clinical evidence. The outcome after treatment was available for 223 of the cases. Horses with a non-articular type I fracture had a better prognosis (91.7%) for return to original or expected level of use than horses with an articular type II or III fracture (69.6% and 74.1%, respectively). The prognosis for types IV and V fractures was fair (57.7% and 57.1%, respectively) and for type VI good (80%). Horses with a hindlimb fracture had a significantly greater chance of a successful outcome. No significant association between age or time to start treatment and success rate was noted. The best treatment option for types I-III fractures was a conservative approach (box rest). Type IV fractures were best treated by arthroscopic removal of the fragment. Immobilisation of the hoof did not seem to influence outcome. Radiological findings and clinical healing were not accurately correlated and the re-commencement of training should be based on clinical rather than radiological findings. Complete osseous union of the fracture was not essential for a successful return to athletic activity. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Clinical study evaluating bone mineral mass in the radius during skeletal growth. Single photon absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Hagino, Hiroshi

    1989-01-01

    Using 125-I single photon absorptiometry, bone mineral measurements were performed on 206 healthy Japanese children (2 to 19 years of age). Bone mineral content (BMC), bone width (BW) and BMC/BW values were determined for the radius at distal 1/6 site (metaphysis) and distal 1/3 site (diaphysis). BMC/BW values at both sites correlated well with body height and weight. Bone mass in the diaphysis (distal 1/3 site) increased linearly during the 2-19 years of skeletal growth, but bone mass in the metaphysis (1/6 site) increased steeply during the pubertal period. In children receiving glucocorticoid therapy, bone mass was reduced in proportion to the duration of drug administration. In children under anticonvulsant therapy, the yearly increse in bone mass was significantly low especially in those patients with poor physical activity levels. Bone mineral decrease in the radius occurred in the children with hypopituitalism, hypothyroidism (cretinism), hyperthyroidism and Turner's syndrome.

  10. Chip fractures from the distal lateral trochlear ridge of the talus of a quarter horse gelding: a veterinary medicine clinical report.

    Science.gov (United States)

    Groves, L

    2005-09-05

    An eighteen-month old quarter horse gelding was diagnosed with chip fractures from the distal lateral trochlear ridge of the talus. The horse presented with the symptom of persistent synovitis. The diagnosis was based on radiographic evidence. The horse was treated initially with arthroscopic surgery. He was given a non-steroidal anti-inflammatory agent, and a chondroprotective agent to prevent further damage to, and aid in the healing of, the damaged joint.

  11. Distal tibiofibular synostosis in a Nigerian: A case report | Owoeye ...

    African Journals Online (AJOL)

    X-ray of the bones showed an oblique fracture in the distal end of the shaft of fibula which is suggestive of post traumatic tibiofibular synostosis (TFS). Knowledge of distal TFS is important in resolving the puzzle of chronic shin pain of unknown origin and in accurate diagnosis of causes of ankle deformity and malformations.

  12. Fixation of supraglenoid tubercle fractures using distal femoral locking plates in three Warmblood horses.

    Science.gov (United States)

    Frei, Sina; Fürst, Anton E; Sacks, Murielle; Bischofberger, Andrea S

    2016-05-18

    Three horses that were presented with supraglenoid tubercle fractures were treated with open reduction and internal fixation using distal femoral locking plates (DFLP). Placing the DFLP caudal to the scapular spine in order to preserve the suprascapular nerve led to a stable fixation, however, it resulted in infraspinatus muscle atrophy and mild scapulohumeral joint instability (case 1). Placing the DFLP cranial to the scapular spine and under the suprascapular nerve resulted in a stable fixation, however, it resulted in severe atrophy of the supraspinatus and infraspinatus muscles and scapulohumeral joint instability (case 2). Placing the DFLP cranial to the scapular spine and slightly overbending it at the suprascapular nerve passage site resulted in the best outcome (case 3). Only a mild degree of supraspinatus and infraspinatus muscle atrophy was apparent, which resolved quickly and with no effect on scapulohumeral joint stability. In all cases, fixation of supraglenoid tubercle fractures using DFLP in slightly different techniques led to stable fixations with good long-term outcome. One case suffered from a mild incisional infection and plates were removed in two horses. Placement of the DFLP cranial to the scapular spine and slightly overbending it at the suprascapular nerve passage prevented major nerve damage. Further cases investigating the degree of muscle atrophy following the use of the DFLP placed in the above-described technique are justified to improve patient outcome.

  13. EPIDEMIOLOGICAL STUDY OF LOW ENERGY FRACTURES IN REPUBLIC OF ARMENIA

    Directory of Open Access Journals (Sweden)

    S. Saakyan

    2017-01-01

    Full Text Available Until present no data was available inArmeniain respect of incidence of low energy fractures that are typical of osteoporotic locations which consequently did not allow to evaluate the scope of this problem across the country.Purpose of the study – to identify the incidence of low energy fractures in proximal femur, in distal forearm, in proximal humerus and in distal tibia across population ofArmenia aged 50 years and older.Materials and methods. An observing population study was performed in two regions of Armenia during 2011-2013 where the frequency of selected locations in cases of moderate trauma was identified. During 2011-2012 the information was collected based on traumatology service records adding in 2013 other sources including primary level of healthcare due to observed infrequent applications for medical help in cases of trauma. Results. In 2013 the incidence of proximal femur fractures in men was reported as 136 cases per 100 000 of population aged 50 years and older, in women – 201 cases per 100 000. At the same time only 57.7% of patients with proximal femur fractures were admitted to hospital. Distal forearm fractures incidence in men and women was observed correspondingly 56/100 000 and 176/100 000 cases, proximal humerus fractures – 39/100 000 and 86/100 000 cases and distal tibia fractures – 39/100 000 and 86/100 000 cases. The predicted annual number of proximal femur fracture in Armenia amounts to 2067 cases, distal forearm fractures – 1205, proximal humerus fractures – 640.Conclusion. Epidemiological data that was collected for the first time on low energy fractures incidence confirmed the acute osteoporosis issue inArmenia and revealed the problems in organization of medical care for the group of senior patients with injuries.

  14. Characterisation of osseous bodies of the distal phalanx of foals

    International Nuclear Information System (INIS)

    Kaneps, A.J.; O'Brien, T.R.; Redden, R.F.; Stover, S.M.; Pool, R.R.

    1993-01-01

    The distal phalanx and metacarpal physis of both forelimbs of 32 Thoroughbred foals 3-32 weeks of age were radiographed to identify those limbs with osseous bodies at a palmar process (PP) of the distal phalanx. Osseous bodies (ossicles) were identified radiographically in 19% of the foals. Sixteen of the 32 foals were selected for microradiographic and histological evaluation: 6 foals with radiographic evidence of ossicles and 10 foals without. Fourteen ossicles of the PP were observed radiographically. Ossicles were either a triangular bone fragment at the palmar aspect of the distal angle of the PP, or an oblong bone fragment separated from P3 by a radiolucent line extending 1-3 cm from the incisure of the PP to the solar margin. One foal had radiographic evidence of bilateral distal metacarpal physitis. Seventeen of 35 PPs examined microradiographically were considered normal, in that the dorsal and solar cortices were thin with trabecular bone orientated parallel to the cortical surfaces, and there was a depression in the dorsal cortical surface (i.e. parietal sulcus). Abnormal microradiographic findings in the other 18 PPs included a fracture line extending from the dorsal cortical surfaces and trabecular bridging of the fracture gap. The fracture line was often continuous with the parietal sulcus. Microradiographic evidence of a fracture was found in 75% of foals evaluated. Normal histological findings in 16 PPs included thin dorsal and solar cortices with trabeculae orientated parallel to the cortical surfaces, parallel-fibred dense connective tissue attachments of the deep digital flexor tendon to the solar cortical surfaces, and a neurovascular bundle associated with the parietal sulcus

  15. Open Fracture of the Forearm Bones due to Horse Bite

    Directory of Open Access Journals (Sweden)

    John Ashutosh Santoshi

    2014-01-01

    Full Text Available Introduction: Fractures have been described mainly following falling accidents in horse-related injuries. Horse bites are uncommon accidents. We present a case of open fracture of the forearm due to horse bite. Case Report: A 35-year-old male farm-worker presented to the emergency room with alleged history of horse bite to the right forearm about 2 hours prior to presentation while feeding the horse. There was deformity of the forearm with multiple puncture wounds, deep abrasions and small lacerations on the distal-third of the forearm. Copious irrigation with normal saline was done and he was administered anti-tetanus and post-exposure rabies prophylaxis. Prophylactic antibiotic therapy was commenced. Radiographs revealed fracture of radius and ulna in the mid-shaft region. He underwent emergency wound debridement, and the ulna was stabilised with an intra-medullary square nail. Seventy-two hours later, he underwent re-debridement and conversion osteosynthesis. He had an uneventful recovery and at three-month follow-up, the fractures had healed radiographically in anatomic alignment. At two-year follow-up, he is doing well, is pain free and has a normal range of motion compared to the contralateral side. Conclusion: Horse bites behave as compound fractures however rabies prophylaxis will be needed and careful observation is needed. Early radical debridement, preliminary skeletal stabilisation, re-debridement and conversion osteosynthesis to plate, and antibiotic prophylaxis were the key to the successful management of our patient. Keywords: Horse; animal bite; forearm; open fracture

  16. Frequency distributions of 174 fractures of the distal condyles of the third metacarpal and metatarsal bones in 167 Thoroughbred racehorses (1999-2009).

    Science.gov (United States)

    Jacklin, B D; Wright, I M

    2012-11-01

    Although fractures of the metacarpal and metatarsal condyles are the most common long-bone fractures of Thoroughbred horses in training, limited data on variations in morphology and incidence have been published. Additionally, grouped analyses of previous studies from the UK and USA would permit comparison between study groups and the creation of a substantial pool of international data. Retrospective analysis of case records of horses with fractures of the distal condyles of third metacarpal/metatarsal bones seen over the last 10 years at Newmarket Equine Hospital. The current series was compared with a prior series from the UK; pooled analyses of these, and series from the USA were also compared. One hundred and seventy-four fractures were identified in 167 racehorses. The current series contained a significantly lower proportion of medial condylar fractures than in a similar population 17 years earlier. Fractures that originated more abaxially tended to be shorter, and a significant proportion of lateral condylar fractures arose outside of the condylar groove. There was also some apparent seasonality of fractures of the lateral condyles in 2-year-old horses, but not so in older horses or those with medial condylar fractures. A substantial portion (approximately 50%) of fractures in the present series cannot be explained by unifying theories of aetiopathogenesis, which suggest that fractures usually arise within the condylar groove, as a focus of cumulative fatigue and failure of adaptation of bone. A separate aetiopathogenesis may be responsible for a proportion of condylar fractures encountered in racehorses, and further work is required to elucidate this. Changes in the number of medial condylar fractures encountered may reflect the introduction of artificial racing and training surfaces, and also may reflect changes in the age demographic of horses racing in the UK since the introduction of year-round 'all-weather' racing. © 2012 EVJ Ltd.

  17. CURBSIDE CONSULTATION IN FRACTURE MANAGEMENT: 49 CLINICAL QUESTIONS

    Directory of Open Access Journals (Sweden)

    Walter W. Virkus

    2008-12-01

    Full Text Available DESCRIPTION: A user-friendly, unique resource for the treatment of fractures designed in a casual questions and answers format which provides basic knowledge, current information and evidence based expert advices enhanced by images and diagrams and supported by ref-erences.PURPOSE: Designing this book the editor has aimed to prepare not only a source of current knowledge and opin-ions by experienced authors in fracture management for decision making in daily practice but also a brief refer-ence and useful educational resource in orthopedic trauma surgery.FEATURES: Three Sections are composed of 49 sub-jects in a form of the answers of frequently asked ques-tions richly illustrated by images and diagrams and in-cluding references at the end of each subject.The Section I is “UPPER EXTREMITIES” including: Neck fracture; Humerus shaft fracture; Management of radial nerve palsy associated with humeral fracture; Clavicle fractures; Elbow fractures in children; Fasciot-omy technic of the forearm; Distal radius fracture; Indica-tions of radial head replacement, Femur and humeral shaft fractures; Treatment of posterolateral elbow dislocation; The Section II is “LOWER EXTREMITIES” including : Femur fractures; Pelvic fractures; Life threatening pelvic fractures; Decision for surgical treatment in pelvic frac-tures; Treatment of anterior fracture of femoral head and hip joint incongruity; Management of a displaced femoral neck fracture in young patient in ER; Elder patients with displaced femoral head fracture; Patella and tibial plateau fractures; Criteria for compartment syndromes in the tibia; Tricks in nailing proximal and distal tibial fractures; Surgical management of distal tibia spiral fracture in middle aged women; Pilon fracture; Management of syn-desmotic screws in adult patient; The management of minimally displaced posterior malleol in three malleolar fractures; Postoperative management of bimalleolar frac-tures; Management of minimally

  18. [Intramedullary osteosynthesis of distal metacarpal fractures with curved wires].

    Science.gov (United States)

    Schlageter, M; Winkel, R; Porcher, R; Haas, H G

    1997-07-01

    When intramedullary pinning is used to treat metacarpal fractures, as recently described by Förstner (1994) and Foucher (1995), the closed reduction technique developed by Jahss (1938) is applied in the same way as for conservative fracture treatment. It is not always possible to achieve complete anatomical reduction using this closed technique. The intramedullary pinning technique, that we have applied since 1989, involves a Kirschner wire which is bent at one end. Apart from reducing the fracture, the pre-set Kirschner wire serves as a butressing internal fixator. The elastic clamping of the wire acts as an internal wire spring splint, permitting early mobilisation. We have operated on 62 metacarpal fractures using the above-mentioned technique over a period of 6 years until 1995. Anatomic reduction was realized in 50 of 62 fractures. In the follow-up of 32 fractures, we noticed four complications: one infection, two paraesthesias, and one non-union.

  19. Effects of Odanacatib on the Radius and Tibia of Postmenopausal Women

    DEFF Research Database (Denmark)

    Cheung, Am; Majumdar, S; Brixen, K

    2014-01-01

    results, odanacatib was superior to placebo with respect to increases in trabecular volumetric BMD (vBMD) and estimated compressive strength at the spine, and integral and trabecular vBMD and estimated strength at the hip. Here we report the results of HR-pQCT assessment. 214 postmenopausal women (mean.......64% and 2.66%). At the distal radius, odanacatib significantly improved trabecular thickness and BV/TV versus placebo. At a more proximal radial site, odanacatib attenuated the increase in cortical porosity seen with placebo (treatment difference= -7.7%, p = 0.066). At the distal tibia, odanacatib...... significantly improved trabecular number, separation, and BV/TV versus placebo. Safety and tolerability were similar between treatment groups. In conclusion, odanacatib increased cortical and trabecular density, cortical thickness, aspects of trabecular microarchitecture, and estimated strength at the distal...

  20. Traumatic Foot Fractures in Hard Working Donkeys

    Directory of Open Access Journals (Sweden)

    M.A. Semieka

    2012-10-01

    Full Text Available The present study was carried out on 45 hard working donkeys suffering from different types of traumatic foot fractures. These animals were selected from the clinical cases admitted to the Veterinary Teaching Hospital, Assiut University during the period of 2007-2010. Based on history, clinical signs and radiographic examination, various types of traumatic foot fractures were diagnosed and recorded. These fractures were affect metacarpal bones (N. =16, metatarsal bones (N. =9, proximal phalanx (N. = 13, middle phalanx (N. = 3, distal phalanx (N. = 2 and proximal sesamoid bones (N. = 2. It could be concluded that fractures of the large metacarpal bones are the most common types followed by fractures of the proximal phalanx of the thoracic limb then fractures of the metatarsal bones. Fractures of the middle phalanx, distal phalanx and proximal sesamoid bone are less common in donkeys. Single fractures of the metacarpal and metatarsal bones are more common than comminuted one, in addition diaphyseal fractures of these bones are more common than metaphyseal or epiphyseal fractures. In the proximal phalanx, comminuted fractures are more common than single fractures.

  1. Pylon fractures of the ankle: A distinct clinical and radiological entity

    International Nuclear Information System (INIS)

    Mainwaring, B.L.; Daffner, R.H.; Riemer, B.L.

    1987-01-01

    Pylon fractures are a distinct clinical and radiological entity that should not be confused with trimalleolar fractures. Radiographic and clinical comparison of 20 cases of each fracture type revealed definite distinguishing features. First, pylon fractures inevitably were associated with profound comminution of the distal tibia. The trimalleolar injury was associated with fractures of the medial, lateral, and posterior malleoli without comminution. Second, in contrast to timalleolar fractures, pylon fractures had intraarticular extension of at least one tibial fracture through the dome of the plafond. Third, 60% of all pylon fractures were associated with a fractured talus; the talus was intact in all trimalleolar fractures. Fourth, the distal tibiofibular syndesmosis was constant in the pylon fractures but was separated in all trimalleolar fractures

  2. Concave distal end of ulna metaphysis alone is not a sign of rickets

    Energy Technology Data Exchange (ETDEWEB)

    Oestreich, Alan E. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, 5031, Cincinnati, OH (United States)

    2015-07-15

    Statements have been made in the literature and in legal testimony that misrepresent the radiographic finding of concave distal end of the ulnar metaphysis. To demonstrate that a concave distal end of the ossified ulna in infancy can be normal. Eighty distal wrists of randomly selected infants in the first year of life with radiographic evidence that ruled out rickets were reviewed. In 16 of the cases (20%), mild or moderate concavity of the distal end of the ulna was seen. An intact metaphyseal collar of distal radius or ulna confirmed the absence of radiographic rickets. The finding of 20% of concave distal ulnas in the first year of life confirms the widely acknowledged statements that concave distal end of the ulna alone is not indicative of rickets. Statements to the contrary are not justified. (orig.)

  3. Concave distal end of ulna metaphysis alone is not a sign of rickets

    International Nuclear Information System (INIS)

    Oestreich, Alan E.

    2015-01-01

    Statements have been made in the literature and in legal testimony that misrepresent the radiographic finding of concave distal end of the ulnar metaphysis. To demonstrate that a concave distal end of the ossified ulna in infancy can be normal. Eighty distal wrists of randomly selected infants in the first year of life with radiographic evidence that ruled out rickets were reviewed. In 16 of the cases (20%), mild or moderate concavity of the distal end of the ulna was seen. An intact metaphyseal collar of distal radius or ulna confirmed the absence of radiographic rickets. The finding of 20% of concave distal ulnas in the first year of life confirms the widely acknowledged statements that concave distal end of the ulna alone is not indicative of rickets. Statements to the contrary are not justified. (orig.)

  4. Does bone measurement on the radius indicate skeletal status. Concise communication

    International Nuclear Information System (INIS)

    Mazess, R.B.; Peppler, W.W.; Chesney, R.W.; Lange, T.A.; Lindgren, U.; Smith, E. Jr.

    1984-01-01

    Single-photon (I-125) absorptiometry was used to measure bone mineral content (BMC) of the distal third of the radius, and dual-photon absorptiometry (Gd-153) was used to measure total-body bone mineral (TBBM), as well as the BMC of major skeletal regions. Measurements were done in normal females, normal males, osteoporotic females, osteoporotic males, and renal patients. The BMC of the radius predicted TBBM well in normal subjects, but was less satisfactory in the patient groups. The spinal BMC was predicted with even lower accuracy from radius measurement. The error in predicting areal density (bone mass per unit projected skeletal area) of the lumbar and thoracic spine from the radius BMC divided by its width was smaller, but the regressions differed significantly among normals, osteoporotics, and renal patients. There was a preferential spinal osteopenia in the osteoporotic group and in about half of the renal patients. Bone measurements on the radius can indicate overall skeletal status in normal subjects and to a lesser degree in patients, but these radius measurements are inaccurate, even on the average, as an indicator of spinal state

  5. Feasibility of a reduction protocol in the emergency department for diaphyseal forearm fractures in children.

    Science.gov (United States)

    Pesenti, S; Litzelmann, E; Kahil, M; Mallet, C; Jehanno, P; Mercier, J-C; Ilharreborde, B; Mazda, K

    2015-09-01

    Diaphyseal forearm fractures are very common pediatric traumas. At present, distal radius metaphyseal fractures are often successfully treated with closed reduction by emergency physicians. However, the management of diaphyseal fractures remains controversial. The purpose of this study was to analyze the results of diaphyseal forearm fractures in the emergency department (ED) in children. In a prospective 2-year-study, all closed diaphyseal forearm fractures in patients under 15, with an angle of >15° and treated by closed reduction in the ED were included. Fractures with overlapping fragments were excluded. Reduction was performed by an emergency physician, with a standardized analgesic protocol (painkillers and nitrous oxide). Clinical tolerance was checked within the first 24hours, and the radiographic stability of reduction was assessed at days 8 and 15. Initial and final follow-up radiographs were analyzed. Elbow and wrist range of motion was assessed at the final follow-up. Sixty patients (41 boys and 19 girls) were included. Mean age was 5.2 years old (±3). At initial evaluation, the maximum angle was 30° (±11.3). After reduction, the maximum angle was significantly reduced (30° vs. 5°, P<0.001). Mean immobilization in a cast was 11.7 weeks (±2). There were no cast related complications in any of these children. There was no surgery for secondary displacement. Full range of motion was obtained in all patients at the final follow-up. The outcome of conservative treatment of closed diaphyseal forearm fractures, without overlapping fragments was excellent. However, reduction is usually performed in the operating room by orthopedic surgeons under general anesthesia and requires hospitalization, which is very expensive. The results of this study show that high quality care may be obtained in the ED by a trained and experienced team. These results are similar to those for distal metaphyseal fractures, which could extend the indications for reduction in the

  6. Imaging of the Distal Tibiofibular Syndesmosis: Anatomy in Relation to Radiological Diagnosis

    NARCIS (Netherlands)

    J.J. Hermans (John)

    2011-01-01

    textabstractInjury to the distal tibiofibular syndesmosis can occur after an ankle sprain or after an acute ankle fracture. In an estimated 1-11% of all ankle sprains, injury of the distal tibiofibular syndesmosis occurs which is known as a high ankle sprain. However, depending on the type and

  7. The use of small (2.7 mm) screws for arthroscopically guided repair of carpal chip fractures.

    Science.gov (United States)

    Wright, I M; Smith, M R W

    2011-05-01

    Removal of large chip fractures of the carpal bones and the osteochondral deficits that result, have been associated with a worse prognosis than removal of small fragments in similar locations. Reducing the articular defects by repair of large osteochondral fragments may have advantages over removal. Horses with osteochondral chip fractures that were of sufficient size and infrastructure to be repaired with small (2.7 mm diameter) AO/ASIF cortex screws were identified and repair effected by arthroscopically guided internal fixation. Thirty-three horses underwent surgery to repair 35 fractures of the dorsodistal radial carpal bone (n = 25), the dorsal margin of the radial facet of the third carpal bone (n = 9) and the intermediate facet of the distal radius (n = 1). There were no surgical complications and fractures healed satisfactorily in 26 of 28 horses and 23 horses returned to racing performance. Arthroscopically guided repair of carpal chip fractures with small diameter cortex screws is technically feasible and experiences with 33 cases suggest that this may have advantages over fragment removal in managing such cases. Surgeons treating horses with large chip fractures of the carpal bones should consider arthroscopically guided internal fixation as an alternative to removal. © 2010 EVJ Ltd.

  8. An unusual stress fracture: Bilateral posterior longitudinal stress fracture of tibia

    OpenAIRE

    Malkoc, Melih; Korkmaz, Ozgur; Ormeci, Tugrul; Oltulu, Ismail; Isyar, Mehmet; Mahirogulları, Mahir

    2014-01-01

    INTRODUCTION Stress fractures (SF) occur when healthy bone is subjected to cyclic loading, which the normal carrying range capacity is exceeded. Usually, stress fractures occur at the metatarsal bones, calcaneus, proximal or distal tibia and tends to be unilateral. PRESENTATION OF CASE This article presents a 58-year-old male patient with bilateral posterior longitudinal tibial stress fractures. A 58 years old male suffering for persistent left calf pain and decreased walking distance for las...

  9. Low levels of 25-hydroxyvitamin D are associated with the occurrence of concomitant upper limb fractures in older women who sustain a fall-related fracture of the hip.

    Science.gov (United States)

    Di Monaco, Marco; Vallero, Fulvia; Castiglioni, Carlotta; Di Monaco, Roberto; Tappero, Rosa

    2011-01-01

    To investigate the association between serum levels of 25-hydroxyvitamin D and the occurrence of simultaneous fractures of the upper limb in older women who sustain a fall-related fracture of the hip. Cross-sectional study. We investigated 472 of 480 white women consecutively admitted to a rehabilitation hospital because of a fall-related hip fracture. Twenty-seven (5.7%) of the 472 women sustained a concomitant upper-limb fracture of either distal radius (20 women) or proximal humerus (seven women). We assessed serum levels of 25-hydroxyvitamin D 14.2 ± 4.1 (mean ± SD) days after surgical repair of the hip fracture in the 472 women by an immunoenzymatic assay. Twenty-five-hydroxyvitamin D levels were significantly lower in the 27 women with concomitant fractures of both hip and upper limb than in the remaining 445 hip-fracture women: mean ± SD values were 6.5 ± 5.0 ng/ml and 11.7 ± 10.4 ng/ml respectively in the two groups (mean difference between groups 5.2 ng/ml: 95% CI 1.2-9.2; p=0.011). Low levels of 25-hydroxyvitamin D were significantly associated with concomitant fractures of the upper limb (p=0.017), after adjustment for eight potential confounders including age, height, weight, hip-fracture type, cognitive impairment, neurologic impairment, previous hip fracture, and previous upper-limb fracture. Low levels of 25-hydroxyvitamin D were significantly associated with concomitant upper-limb fractures in our sample of older women with a fall-related fracture of the hip. Preventing vitamin D deficiency may lower the incidence of simultaneous fractures due to a singe fall in elderly women. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  10. Palmar reconstruction of the triangular fibrocartilage complex for instability of the distal radioulnar joint: a biomechanical study.

    Science.gov (United States)

    Kataoka, T; Moritomo, H; Omokawa, S; Iida, A; Wada, T; Aoki, M

    2013-06-01

    We developed a new triangular fibrocartilage complex reconstruction technique for distal radioulnar joint instability in which the palmar portion of the triangular fibrocartilage complex was predominantly reconstructed, and evaluated whether such reconstruction can restore stability of the distal radioulnar joint in seven fresh cadaver upper extremities. Distal radioulnar joint instability was induced by cutting all soft-tissue stabilizers around the distal ulna. Using a palmar approach, a palmaris longus tendon graft was sutured to the remnant of the palmar radioulnar and ulnocarpal ligaments. The graft was then passed through a bone tunnel created at the fovea and was sutured. Loads were applied to the radius, and dorsopalmar displacements of the radius relative to the ulna were measured using an electromagnetic tracking device in neutral rotation, 60° supination and 60° pronation. We compared the dorsopalmar displacements before sectioning, before reconstruction and after reconstruction. Dorsopalmar instability produced by sectioning significantly improved in all forearm positions after reconstruction.

  11. A patient specific finite element simulation of intramedullary nailing to predict the displacement of the distal locking hole.

    Science.gov (United States)

    Mortazavi, Javad; Farahmand, Farzam; Behzadipour, Saeed; Yeganeh, Ali; Aghighi, Mohammad

    2018-05-01

    Distal locking is a challenging subtask of intramedullary nailing fracture fixation due to the nail deformation that makes the proximally mounted targeting systems ineffective. A patient specific finite element model was developed, based on the QCT data of a cadaveric femur, to predict the position of the distal hole of the nail postoperatively. The mechanical interactions of femur and nail (of two sizes) during nail insertion was simulated using ABAQUS in two steps of dynamic pushing and static equilibrium, for the intact and distally fractured bone. Experiments were also performed on the same specimen to validate the simulation results. A good agreement was found between the model predictions and the experimental observations. There was a three-point contact pattern between the nail and medullary canal, only on the proximal fragment of the fractured bone. The nail deflection was much larger in the sagittal plane and increased for the larger diameter nail, as well as for more distally fractured or intact femur. The altered position of the distal hole was predicted by the model with an acceptable error (mean: 0.95; max: 1.5 mm, in different tests) to be used as the compensatory information for fine tuning of proximally mounted targeting systems. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.

  12. Catastrophic scapular fractures in Californian racehorses: pathology, morphometry and bone density.

    Science.gov (United States)

    Vallance, S A; Spriet, M; Stover, S M

    2011-11-01

    To enhance understanding of the nature and pathogenesis of scapular fractures in racehorses. Scapular fractures in racehorses have a consistent configuration related to sites of pre-existing stress modelling and remodelling. Fractured and intact scapulae collected post mortem were examined visually and with computed tomography (CT). Scapular fracture configuration, bone modelling changes and standardised CT morphometry and density measurements were recorded. Statistical comparisons were made between fractured, nonfractured contralateral and control scapulae. Thirty-nine scapulae from 10 Thoroughbred (TB) and 10 Quarter Horse (QH) racehorses were obtained. All 14 fractured scapulae (from 12 horses) had a consistent comminuted fracture configuration. A complete fracture coursed transversely through the neck of the scapula at the level of the distal aspect of the spine (8.9 ± 0.9 cm proximal to the lateral articular margin of the glenoid cavity). The distal fragment of 13 fractured scapulae was split into 2 major fragments by a fracture in the frontal plane that entered the glenoid cavity (2.8 ± 0.4 cm caudal to the cranial articular margin). Focal areas of periosteal proliferation and/or radiolucency were present in the distal aspect of the scapular spine of all fractured and intact contralateral scapulae, but less commonly (Phorses without a scapular fracture. Fractured scapulae had 7-10% lower mean density and 46-104% greater density heterogeneity in the spine adjacent to the transverse fracture compared to control scapulae (Pfracture configuration that is associated with pre-existing pathology of the distal aspect of the spine. This location is consistent with scapular stress fractures diagnosed in lame TB racehorses. Catastrophic fracture is the acute manifestation of a more chronic process. Consequently, there are opportunities for early detection and prevention of fatalities. © 2010 EVJ Ltd.

  13. Location of civilian ballistic femoral fracture indicates likelihood of arterial injury.

    Science.gov (United States)

    Gitajn, Leah; Perdue, Paul; Hardcastle, John; O'Toole, Robert V

    2014-10-01

    We evaluated whether the location of a ballistic femoral fracture helps predict the presence of arterial injury. We hypothesized that fractures located in the distal third of the femur are associated with a higher rate of arterial injury. We conducted a retrospective review of electronic medical records at our level I trauma centre and found 133 consecutive patients with femoral fractures from civilian gunshots from 2002 to 2007, 14 of whom sustained arterial injury. Fracture extent was measured with computerized viewing software and recorded with a standard technique, calculating proximal, distal, and central locations of the fracture as a function of overall length of the bone. Analyses were conducted with Student's t, Chi-squared, and Fisher's exact tests. The location of any fracture line in the distal third of the femur was associated with increased risk of arterial injury (Pballistic injury is six times more likely to be associated with arterial injury and warrants careful evaluation. Our data show that fracture location can help alert clinicians to possible arterial injury after ballistic femoral fracture. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. fracture of the dome of the talus associated with a fracture of the os ...

    African Journals Online (AJOL)

    1971-03-13

    Mar 13, 1971 ... region of the ankle joint is reported. Falls from a height are commonly associated with fractures of the os calcis, the distal tibia and fibula, the acetabulum, the thoracic and lumbar spine and the base of the skull. An association between a fracture of the dome of the talus on one side and a fracture of the os ...

  15. The challenging surgical treatment of closed distal humerus fractures in elderly and octogenarian patients: radiographic and functional outcomes with a minimum follow-up of 24 months.

    Science.gov (United States)

    Biz, Carlo; Sperotto, Silvano Pierluigi; Maschio, Nicola; Borella, Matteo; Iacobellis, Claudio; Ruggieri, Pietro

    2017-10-01

    The main purpose of this retrospective, non-randomized, case series study was to evaluate the clinical and radiographic outcomes of distal humerus fractures (DHFs) in a consecutive series of elderly patients operatively treated by two surgeons, and second, to identify proper indications for two elderly age ranges and two fracture pattern groups. From January 2009 to June 2014, 51 patients (pts) underwent open reduction and internal fixation (ORIF) using the locking compression plate (LCP) distal humerus plate (DHP) system at our institution. Medical records and radiographs were retrospectively assessed. Patients were divided into 3 groups according to gender, age (pts level (55.6%). The mean MEPS was 78.9 points, Quick-DASH 28.4, SF-36 PCS 48.3 and MCS 48.9. There was statistically significant evidence that having a 13-C3 fracture leads to worse results in MEPS, Quick-DASH and SF-36. The female gender correlates with worse results in SF-36. The patients ≥85 years had a worse prognosis according to Quick-DASH and SF-36, while the AO 13-C3 pattern obtained the worst ROM outcomes versus AO 13 B1-B2-C1-C2 (normal ROM 0°-140°): mean ROM 24°-114° vs 10°-130°, mean flexion deficit 26° vs 10°, mean extension deficit 24° vs 10°, respectively). Complications were presents in 36.1% of patients, overall belonging to the AO type 13-C fracture pattern and to the group ≥85 years. These study data seem to confirm our hypothesis that plate fixation for DHFs guarantees adequate fracture osteosynthesis and satisfactory functional outcomes at medium to long-term follow-up, not only in elderly patients, but also in octogenarian osteoporotic patients (≥85 years) with 13-C1 and 13-C2 fracture patterns, while an alternative solution should be considered for type C3 fractures, even in a primary trauma setting.

  16. Treatment of proximal ulna and olecranon fractures by dorsal plating

    NARCIS (Netherlands)

    Kloen, Peter; Buijze, Geert A.

    2009-01-01

    OBJECTIVE : Anatomic reconstruction of proximal ulna and olecranon fractures allowing early mobilization and prevention of ulnohumeral arthritis. INDICATIONS : Comminuted olecranon or proximal ulna fractures (including Monteggia fractures), olecranon fractures extending distally from the coronoid

  17. Evaluation of the Stryker S2 IM Nail Distal Targeting Device for reduction of radiation exposure: a case series study.

    Science.gov (United States)

    Anastopoulos, George; Ntagiopoulos, Panagiotis G; Chissas, Dionisios; Loupasis, George; Asimakopoulos, Antonios; Athanaselis, Eustratios; Megas, Panagiotis

    2008-10-01

    Distal locking is one challenging step during intramedullary nailing of femoral shaft fractures that can lead to an increase of radiation exposure. In the present study, the authors describe a technique for the distal locking of femoral nails, implementing a new targeting device in an attempt to reduce radiation exposure and operational time. Over a 2-year period, 127 consecutive cases of femoral shaft fractures were included in the study. All cases were treated with nailing of femoral shaft fractures with an unslotted reamed antegrade femoral nail and distal locking was performed with the use of a proximally mounted aiming device. Mean duration of the procedure was 63.5 18.1 min while the duration for distal locking was 6.6 +/- 2.6 min. In all successful cases, exposure from intraoperative fluoroscopy was 17.2 +/- 7.4 s for the whole operative procedure, and for distal locking was 2 shots, 1.35 s (range, 0.9-2.2 s) and 1.9 mGy (range, 1.1-2.9 mGy). Five cases (3.9%) were unsuccessful, but overall no intraoperative complications were encountered from the application of this technique. The ability of the device to correspond to the level of nail deformation and to properly identify the distal holes, reduced exposure to radiation compared to other published reports, and should be considered as a valuable tool for distal locking of femoral fractures.

  18. Surgical treatment of distal biceps tendon rupture: a case report

    Directory of Open Access Journals (Sweden)

    Cristina N. Cozma

    2017-11-01

    Full Text Available Objectives. Distal biceps tendon rupture affects the functional upperextremity movement, impairing supination and flexion strength. According to age, profession and additional risks treatment might be nonoperative or surgical. Methods. We describe the case of a 43 years old male patient who sustained an injury to his right distal biceps and was diagnosed with acute right distal biceps rupture. Surgical treatment was decided and biceps tendon was reinserted to the radius tuberosity using a combination of a cortical button fixation associated with an interference screw. Results. Postoperative functional result was favorable with no complications and with no movement limitation after one month. Conclusions. When possible, distal biceps tendon repair should be realized surgically because this permits restoring of the muscle strength to near normal levels with no loss of motion. Nerve complications are common; therefore the surgery should be realized by experienced upper extremity surgeons.

  19. Distal radioulnar joint: functional anatomy, including pathomechanics.

    Science.gov (United States)

    Haugstvedt, J R; Langer, M F; Berger, R A

    2017-05-01

    The distal radioulnar joint allows the human to rotate the forearm to place the hand in a desired position to perform different tasks, without interfering with the grasping function of the hand. The ulna is the stable part of the forearm around which the radius rotates; the stability of the distal radioulnar joint is provided by the interaction between ligaments, muscles and bones. The stabilizing structures are the triangular fibrocartilage complex, the ulnocarpal ligament complex, the extensor carpi ulnaris tendon and tendon sheath, the pronator quadratus, the interosseous membrane and ligament, the bone itself and the joint capsule. The purpose of this review article is to present and illustrate the current understanding of the functional anatomy and pathomechanics of this joint.

  20. Digital Tomosynthesis to Evaluate Fracture Healing: Prospective Comparison With Radiography and CT.

    Science.gov (United States)

    Ha, Alice S; Lee, Amie Y; Hippe, Daniel S; Chou, Shinn-Huey S; Chew, Felix S

    2015-07-01

    Radiography, currently the standard for postoperative fracture imaging, is limited by overlapping bone and hardware. Tomosynthesis has the benefit of level-by-level imaging without the disadvantages of metal artifacts, increased radiation, and higher costs of CT, the current problem-solving tool. The purpose of this study was to compare tomosynthesis with radiography for evaluating fracture healing. In a prospective study, patients within 1 year of wrist hardware fixation underwent radiography, tomosynthesis, and CT, and the images were interpreted by three readers. The diagnostic accuracy of radiology and tomosynthesis was assessed with ROC curves, and interreader agreement was assessed with Cohen kappa. Fracture scores were correlated with Disabilities of the Arm, Shoulder, and Hand (DASH) and pain scores. The study participants were 49 patients with 51 fractures. The most common fracture sites were distal radius (43%), scaphoid (18%), and metacarpals (18%). Rates of cortex obscuration by hardware were 2% for CT, 8% for tomosynthesis, and 15% for radiography (p tomosynthesis than with radiography (AUC, 0.84 vs 0.76, p = 0.01). Inter-reader agreement was moderate for both radiography and tomosynthesis (κ = 0.44 vs 0.55, p = 0.051). There was no significant correlation between fracture scores and DASH scores. There was significant correlation between reported pain levels and both tomosynthesis (r = 0.28, p = 0.03) and CT (r = 0.29, p = 0.04) fracture scores. Tomosynthesis provides diagnostic information superior to that of ra diography in postoperative evaluation of wrist fractures with lower cost and radiation than CT and should be considered in fracture follow-up imaging of other bones.

  1. Cuttable plate fixation for small breed dogs with radius and ulna fractures: Retrospective study of 31 dogs.

    Science.gov (United States)

    Watrous, Gwyneth K; Moens, Noel M M

    2017-04-01

    This retrospective study evaluated complication rates for radius and ulna fractures in small breed dogs in which 1.5 mm to 2.7 mm cuttable bone plates were used for internal fixation. The medical records of all cases from 2004 to 2011 that were presented to our clinic were reviewed. Inclusion criteria were: dogs with body weight dogs met the inclusion criteria. Of 25 dogs that were available for follow-up, all achieved union, minor complications occurred in 9, and major complications occurred in 8. External coaptation was responsible for complications in 8 cases and the need for coaptation needs to be investigated. Excluding minor complications, 32% of patients required at least 1 additional surgery or additional hospitalization. All but 2 of the dogs returned to full function. The 1.5 mm straight plate was successfully used in all dogs with a body weight of 0.9 to 2.6 kg.

  2. Hand fractures: A study of their site and type in childhood

    International Nuclear Information System (INIS)

    Rajesh, Arumugam; Basu, Avi K.; Vaidhyanath, Ramachandran; Finlay, David

    2001-01-01

    AIM: The purpose of the study was to document the site and type of fractures of the hand in children up to 16 years of age. MATERIALS AND METHODS: The radiographs of 280 children who were found to have a fracture in Accident and Emergency over a one-year period were reviewed. A total of 293 fractures of the hand and 3 distal interphalangeal joint dislocations without fracture were identified. There were 293 fractures as some children had more than one fracture. RESULTS: Distal tuft fractures were commonest in the 0 to 4-year age-group; fractures of distal phalanx (both transverse and tuft) in the 5 to 8-year age-group; transverse fractures of the proximal phalanx of little finger in the 9 to 12-year age-group and transverse fractures of neck of the fifth metacarpal in the 13 to 16-year age-groups. CONCLUSION: Hand fractures are more common in older children, with a male preponderance in most groups except in the 0-4 age-group. The site of injury is different in the various corresponding age-groups, reflecting the differing mechanisms of injury. The management of hand fractures rely on a correct diagnosis and a knowledge of their common site in each age-group should aid diagnosis. Rajesh, A. et al. (2001)

  3. One-stage lengthening using a locked nailing technique for distal femoral shaft nonunions associated with shortening.

    Science.gov (United States)

    Wu, Chi-Chuan; Lee, Zhon-Liau

    2004-02-01

    To assess the effectiveness of a one-stage lengthening using a locked nail technique for the treatment of distal femoral shaft nonunions associated with shortening. Retrospective. University hospital. During a 6-year period, 36 distal femoral shaft nonunions associated with shortening (>1.5 cm) were treated by the one-stage lengthening technique. Indications for this technique were distal femoral shaft aseptic or quiescent infected nonunions, 1.5-5 cm shortening, and a fracture level suitable for the insertion of two distal locked screws. The surgical technique involved skeletal traction using the femoral condyle, local débridement, lengthening by lengthening was 2.5 cm (range 1.5-3.5 cm). One-stage lengthening using the locked nailing technique to treat distal femoral shaft nonunions associated with shortening can achieve a high success rate and low complication rate. The key to successful treatment is the patient's complete cooperation with strictly protected weight bearing until the fracture has healed.

  4. Canine total knee replacement performed due to osteoarthritis subsequent to distal femur fracture osteosynthesis: two-year objective outcome.

    Science.gov (United States)

    Eskelinen, E V; Liska, W D; Hyytiäinen, H K; Hielm-Björkman, A

    2012-01-01

    A 27-kg German Shorthaired Pointer was referred for evaluation due to the complaint of left pelvic limb lameness and signs of pain in the left stifle joint. Radiographs revealed signs of a healed supracondylar femoral fracture that had been previously repaired at another hospital with an intramedullary pin and two cross pins. In addition, there were signs of severe osteoarthritis (OA). The OA had been managed medically with administration of carprofen and nutraceuticals for nine months without any improvement. Left total knee replacement (TKR) surgery was performed to alleviate signs of pain. The patient was assessed preoperatively and at six months, one year, and two years after surgery using radiology, force platform analysis of gait, thigh circumference measures, goniometry, and lameness evaluation. Following surgery, the dog resumed normal activity without any signs of pain and a good quality of life at 3.5 months. Force plate analysis found that peak vertical force on the TKR limb was 85.7% of the normal contralateral limb after two years. Total knee replacement was a successful treatment to manage knee OA associated with a healed distal femoral fracture and internal fixation in this dog.

  5. Treatment outcomes of intertrochanteric femur fractures treated with DLT™ nail

    Directory of Open Access Journals (Sweden)

    Mehmet Arıcan

    2015-12-01

    Full Text Available Objective: Intramedullary nails frequently use in proximal femur fractures. In this study, 49 patients with intertrochanteric fractures were evaluated clinical and radiological results treated with dyna locking trochanteric (DLT™ nail retrospectively. Methods: Twenty-two (44.9% patients were male and 27 (55.1% patients were female. Mean age was 74.29±1.98 (28-99 years and Followed up for a mean of 14.35±3.43 (9-24 months. Thirty-seven (75.6% of the fractures resulted from simple falls while 6 (12.2% caused from traffic accidents and 6 (12.2% fall down from height. There were 24 (49.0% left and 25 (51.0% right lower extremities fractured. According to Orthopaedic Trauma Association classification system; 21 (42.9%, 21 (42.9% and 7 (14.2% fractures were classified as 31A1, 31A2, and 31A3 respectively. One (2.0% patient had claviculae fracture, 3 (6.1% patients had radius distal fracture and 1 (2.0% patient had total knee arthroplasty. After surgery, X-ray was used for radiological results and functional outcomes were evaluated according to the Harris hip scoring system. Results: The average waiting time for the surgery was 2.02±0.18 (1-7 days and hospitalization time was 6.23±0.29 (4-15 days. Mean fracture healing time was 11.74±1.82 (8-15 weeks. Three patients had screw cut-out in the follow-up time and performed hemiarthroplasty. The average Harris hip score was 88.02±1.21 (42-97 points and included 29 (59.2% excellent cases, 17 (34.7% good and 3 (6.1% poor. Conclusion: DLT ™ nail is a safe and successful method because of low complication rates, and capability of detection.

  6. Femoral Condyle Fracture during Anterior Cruciate Ligament Reconstruction

    Directory of Open Access Journals (Sweden)

    Selahattin Ozyurek

    2015-07-01

    Full Text Available Dear Editor,We have greatly enjoyed reading the case report entitled “‘Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature in the issue of Arch Bone Jt Surg. 2015;3(2 with great interest. We would like to commend the authors for their detailed and valuable work. Although various case reports have described postoperative distal femur fracture at a range of time intervals (1,2 intraoperative intra-articular distal femur fracture is a unique entity.However, we believe that some important additional observations seem necessary to be contributed through this study. In this article, the authors stated that, to the best of their knowledge, there is no other case report in the literature introducing a femoral condyle fracture during arthroscopic ACL reconstruction or revision reconstruction. Nevertheless, we would like to call the attention of the readers to the fact that that the literature contains one additional case report re‌porting on intraoperative distal femoral coronal plane (Hoffa fracture during primary ACL reconstruction (2. Werner BC and Miller MD presented of case report of an intraoperative distal femoral coronal plane (Hoffa fracture that occurred during independent femoral tunnel drilling and dilation in a primary ACL reconstruction. As in the their case, this type of fracture can occur with appropriately placed femoral tunnels, but the risk can increase with larger graft diameters in patients with smaller lateral femoral condyles The patient was treated with open reduction and internal fixation, without compromise of graft stability and with good recovery of function. We believe that tailoring graft size to the size of the patient is important to prevent similar adverse events.

  7. Non union of the neck of radius: a case report and review of the ...

    African Journals Online (AJOL)

    Fractures of the neck of radius are frequent in trauma. They happen without being noticed at the moment of injury of the elbow or in the context of polytrauma. A case of non union of the radius neck occurring in a young person due to ignorance, during first consultation has been reported by the authors. They insist on the ...

  8. The “communication line” suggests occult posterior malleolar fracture associated with a spiral tibial shaft fracture

    International Nuclear Information System (INIS)

    Hou Zhiyong; Zhang Liping; Zhang Qi; Yao Shuangquan; Pan Jinshe; Irgit, Kaan; Zhang Yingze

    2012-01-01

    Objectives: To demonstrate radiographical characteristics of the relationship between distal spiral tibial shaft fractures and associated occult posterior malleolar fractures (PMF) that confirmed by CT and MRI. Materials and methods: X-rays for a ninety-six patients with spiral tibia fracture and associated PMF were reviewed. All patients additionally had an ankle CT. Patients with a negative CT scans underwent an ankle MRI. Radiographic observations included fracture location, characteristics, and a presence of a fracture line between the two injuries. Results: The spiral tibia fracture line was contiguous with PMF in 89 of 96 cases after evaluation with the CT and MRI. The line connecting the two injuries, which occurs between the medial inferior apex of the spiral tibia fracture line and the posterior superior apex of the PMF was identified as the “communication line”. In 47 of the 89 conjunction fractures, the “communication line” was detectable preoperatively and in 12 cases postoperatively by anteroposterior radiograph. By using the CT and MRI scans, we found that no “communication line” was present in only 7 cases. Conclusion: It is important to understand the nature of the association between distal spiral tibial shaft fractures and occult posterior malleolar fractures for optimal stabilization of the fracture and for appropriate rehabilitation. The “communication line” is a useful diagnostic clue for early recognition the occult PMF and alerts a closer evaluation of the lateral view and further CT examination.

  9. Sauve-Kapandji operation for disorders of the distal radioulnar joint after Colles' fracture. Good results in 12 patients followed for 1.5-4 years

    DEFF Research Database (Denmark)

    Mikkelsen, Søren Søndergaard; Lindblad, Bent Erling; Larsen, Erik Roj

    1997-01-01

    Controversies continue concerning the treatment of the posttraumatic caput ulna syndrome. We have treated 12 patients, mean age 42 (23-77) years, with arthrodesis ad modum Sauve-Kapandji of the distal articulation between the radius and ulna, combined with resection of the ulnar neck. Before...... the operation, all patients had persistent ulnar wrist pain and restricted pronation-supination movement. At follow-up, after a mean of 2 (1.5-4) years, 8 patients had an excellent outcome, 3 a good, and 1 patient had a fair outcome. 10 patients had no wrist pain. The average grip-score improved from 53...

  10. Risk factors for cervical and trochanteric hip fractures in elderly women: a population-based 10-year follow-up study.

    Science.gov (United States)

    Jokinen, Heikki; Pulkkinen, Pasi; Korpelainen, Juha; Heikkinen, Jorma; Keinänen-Kiukaanniemi, Sirkka; Jämsä, Timo; Korpelainen, Raija

    2010-07-01

    We evaluated the contribution of lifestyle-related factors, calcaneal ultrasound, and radial bone mineral density (BMD) to cervical and trochanteric hip fractures in elderly women in a 10-year population-based cohort study. The study population consisted of 1,681 women (age range 70-73 years). Seventy-two percent (n = 1,222) of them participated in the baseline measurements. Calcaneal ultrasound was assessed with a quantitative ultrasound device. BMD measurements were performed at the distal and ultradistal radius by dual-energy X-ray absorptiometry. Forward stepwise logistic regression analysis was used to find the most predictive variables for hip fracture risk. During the follow-up, 53 of the women had hip fractures, including 32 cervical and 21 trochanteric ones. The fractured women were taller and thinner and had lower calcaneal ultrasound values than those without fractures. High body mass index (BMI) was a protective factor against any hip fractures, while low functional mobility was a risk factor of hip fractures. Specifically, high BMI protected against cervical hip fractures, while low physical activity was a significant predictor of these fractures. Similarly, high BMI protected against trochanteric fractures, whereas low functional mobility and high coffee consumption were significant predictors of trochanteric fractures. Cervical and trochanteric hip fractures seem to have different risk factors. Therefore, fracture type should be taken into account in clinical fracture risk assessment and preventative efforts, including patient counseling. However, the study is not conclusive due to the limited number of observed fractures during follow-up, and the results have to be confirmed in future studies.

  11. Uncommon Dorsal Radiocarpal Fracture Dislocation Complicated With Median Nerve Palsy: Case Report, Review of the Literature, and a New Classification System Guiding the Management

    Directory of Open Access Journals (Sweden)

    Hing-Cheong Wong

    2012-06-01

    Full Text Available We report the case of a 36-year-old lorry driver who sustained left dorsal radiocarpal fracture dislocation and left median nerve injury in a traffic accident in 2010. Emergency operation of closed reduction, cross-wrist-bridging external fixation, percutaneous transradial styloid Kirschner wire fixation, decompression of left median nerve, and repair of the partially torn palmar radiocarpal ligament were performed under general anaesthesia. Because of the persistent depressed dorsal articular rim fracture of left distal radius, another operation of open reduction, corticocancellous bone grafting, and dorsal buttress plating was performed 5 days after the initial operation. Six months after the operation, the patient enjoyed good range of wrist motion but weak twisting power, especially in supination. There was no radiological feature of radiocarpal subluxation.

  12. Ultrasound-Diagnosed Tibia Stress Fracture: A Case Report.

    Science.gov (United States)

    Amoako, Adae; Abid, Ayesha; Shadiack, Anthony; Monaco, Robert

    2017-01-01

    Stress fractures are a frequent cause of lower extremity pain in athletes, and especially in runners. Plain imaging has a low sensitivity. Magnetic resonance imaging (MRI) or bone scan scintigraphy is the criterion standard, but expensive. We present the case of a young female distance runner with left shin pain. Plain radiography was unremarkable. Ultrasound showed focal hyperechoic elevation of the periosteum with irregularity over the distal tibia and increased flow on Doppler. These findings were consistent with a distal tibia stress fracture and confirmed by MRI. Examination of our case will highlight the utility of considering an ultrasound for diagnosis of tibial stress fracture.

  13. Ultrasound-Diagnosed Tibia Stress Fracture: A Case Report

    Directory of Open Access Journals (Sweden)

    Adae Amoako

    2017-04-01

    Full Text Available Stress fractures are a frequent cause of lower extremity pain in athletes, and especially in runners. Plain imaging has a low sensitivity. Magnetic resonance imaging (MRI or bone scan scintigraphy is the criterion standard, but expensive. We present the case of a young female distance runner with left shin pain. Plain radiography was unremarkable. Ultrasound showed focal hyperechoic elevation of the periosteum with irregularity over the distal tibia and increased flow on Doppler. These findings were consistent with a distal tibia stress fracture and confirmed by MRI. Examination of our case will highlight the utility of considering an ultrasound for diagnosis of tibial stress fracture.

  14. EVALUATION OF FUNCTIONAL OUTCOME AFTER OPEN REDUCTION AND INTERNAL FIXATION OF DISTAL FEMUR FRACTURES BY LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    L. Lokanadha Rao

    2016-09-01

    Full Text Available BACKGROUND In the supra and intercondylar fractures of femur particularly with intra articular extension, patient may develop stiffness of knee, shortening, rotational deformities, internal derangement of knee with instability, varus and valgus deformities which affect patient’s routine lifestyle. If these cases were treated with locking compression plate, the results obtained were successful, superior, timesaving providing early ambulation and least disability improving the functional outcome. MATERIALS AND METHODS This is a prospective interventional study. This study includes 25 supracondylar and intercondylar fractures of femur (both Muller’s Type ‘A’, Type B and Type ‘C’ fractures treated with open reduction and internal fixation by Locking Compression Plate in the Department of Orthopaedics, King George Hospital, Visakhapatnam from September 2013 to September 2015. There are 16 males and 9 females with age ranging from 20 to 80 years with an average of 44.6 years. Average age for males is 28.9 years and average age for females is 25 years. 18 fractures were due to road traffic accidents and 6 cases are due to fall from significant heights, 1 case due to simple fall from standing (osteoporosis. 15 cases were in right femur (60% and 10 cases were in left femur (40%. RESULTS 25 cases were included in the study. There is an increase in the rate of union, decreased time taken for union, increased knee range of motion, decreased time for weight-bearing, postoperative complications and duration for hospital stay. CONCLUSION LCP proved to be a good implant which could take the challenges like poor bone stock, severe comminution both metaphyseal and articular and prove successful. The locking head screws distally have prevented varus collapse, even in cases of osteoporosis. The Condylar LCP can be used in either an open or a minimally invasive manner.

  15. Bone stress in runners with tibial stress fracture.

    Science.gov (United States)

    Meardon, Stacey A; Willson, John D; Gries, Samantha R; Kernozek, Thomas W; Derrick, Timothy R

    2015-11-01

    Combinations of smaller bone geometry and greater applied loads may contribute to tibial stress fracture. We examined tibial bone stress, accounting for geometry and applied loads, in runners with stress fracture. 23 runners with a history of tibial stress fracture & 23 matched controls ran over a force platform while 3-D kinematic and kinetic data were collected. An elliptical model of the distal 1/3 tibia cross section was used to estimate stress at 4 locations (anterior, posterior, medial and lateral). Inner and outer radii for the model were obtained from 2 planar x-ray images. Bone stress differences were assessed using two-factor ANOVA (α=0.05). Key contributors to observed stress differences between groups were examined using stepwise regression. Runners with tibial stress fracture experienced greater anterior tension and posterior compression at the distal tibia. Location, but not group, differences in shear stress were observed. Stepwise regression revealed that anterior-posterior outer diameter of the tibia and the sagittal plane bending moment explained >80% of the variance in anterior and posterior bone stress. Runners with tibial stress fracture displayed greater stress anteriorly and posteriorly at the distal tibia. Elevated tibial stress was associated with smaller bone geometry and greater bending moments about the medial-lateral axis of the tibia. Future research needs to identify key running mechanics associated with the sagittal plane bending moment at the distal tibia as well as to identify ways to improve bone geometry in runners in order to better guide preventative and rehabilitative efforts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. A unique physeal injury of the distal phalanx.

    Science.gov (United States)

    Berber, Onur; Singh, Bijayendra

    2015-01-01

    An unusual Salter-Harris Type 1 fracture variant of the distal phalanx of the index finger is described. The epiphysis was dislocated, sitting dorsally over the middle phalanx head with the articular surface facing dorsal. Reduction could only be achieved through an open procedure. The reduction was stable without supplemental fixation.

  17. Distally based superficial sural artery flap for soft tissue coverage in the distal 2/3 of leg and foot

    Directory of Open Access Journals (Sweden)

    Kamath B

    2005-01-01

    Full Text Available Background: Skin coverage for defects in the lower 2/3 of leg, ankle region and posterior heel has always been a difficult challenge for reconstructive surgeon. Methods: We describe our experience with the distally based superficial sural artery flap coverage in 48 patients with moderate sized defects in these difficult areas. Results: One out of 48 flaps (in 48 patients was lost totally and 3 suffered marginal necrosis which did not require any secondary procedure. These complications could have been avoided by proper selection of cases and refining technical skills. Conclusion: This simple procedure could be an important and versatile tool for any reconstructive surgeon in providing skin coverage in the distal leg and proximal foot. Preservation of major arteries of the lower limb, minimal donor defect, relatively uninjured donor area in compound fracture or poly trauma involving distal leg are some of the advantages of the flap.

  18. Triplane fracture of the distal tibial epiphysis: radiographic and CT studies

    International Nuclear Information System (INIS)

    Cone, R.O. III; Nguyen, V.; Flournoy, J.G.; Guerra, J. Jr.

    1984-01-01

    The authors analyzed six cases of triplane fracture of the ankle and reviewed the literature. A previously underscribed fracture pattern was identified in one patient. CT studies proved to be useful diagnostic tools in the evaluation of triplane fractures when operative reduction was contemplated

  19. Qualitative assessment of bone density at the distal articulating surface of the third metacarpal in Thoroughbred racehorses with and without condylar fracture.

    Science.gov (United States)

    Loughridge, A B; Hess, A M; Parkin, T D; Kawcak, C E

    2017-03-01

    Changes in subchondral bone density, induced by the repetitive cyclical loading of exercise, may potentiate fatigue damage and the risk of fracture. To use computed tomography (CT) to characterise bone density patterns at the articular surface of the third metacarpal bone in racehorses with and without lateral condylar fractures. Case control METHODS: Computed tomographic images of the distal articulating surface of the third metacarpal bone were obtained from Thoroughbred racehorses subjected to euthanasia in the UK. Third metacarpal bones were divided into 3 groups based on lateral condyle status; fractured (FX, n = 42), nonfractured contralateral condyle (NFX, n = 42) and control condyles from horses subjected to euthanasia for reasons unrelated to the third metacarpal bone (control, n = 94). Colour CT images were generated whereby each colour represented a range of pixel values and thus a relative range of bone density. A density value was calculated qualitatively by estimating the percentage of each colour within a specific region. Subchondral bone density was assessed in 6 regions from dorsal to palmar and 1 mm medial and lateral to the centre of the lateral parasagittal groove in NFX and control condyles and 1 mm medial and lateral to the fracture in FX condyles. Bone density was significantly higher in the FX and NFX condyles compared with control condyles for all 6 regions. A significantly higher bone density was observed in FX condyles relative to NFX condyles in the lateral middle and lateral palmar regions. Fractured condyles had increased heterogeneity in density among the 6 regions of interest compared with control and NFX condyles. Adjacent to the fracture, a focal increase in bone density and increased heterogeneity of density were characteristic of limbs with lateral condylar fractures compared with control and NFX condyles. These differences may represent pathological changes in bone density that increase the risk for lateral condylar fractures in

  20. Less invasive plate osteosynthesis in humeral shaft fractures.

    Science.gov (United States)

    Apivatthakakul, Theerachai; Phornphutkul, Chanakarn; Laohapoonrungsee, Anupong; Sirirungruangsarn, Yuddhasert

    2009-12-01

    Stable internal fixation of the humeral shaft by less invasive percutaneous plate insertion using two separate (proximal and distal) incisions, indirect reduction by closed manipulation and fixation to preserve the soft tissue and blood supply at the fracture zone. Early mobilization of the shoulder and elbow to ensure a good functional outcome. Humeral shaft fractures (classified according to AO classification as: 12-A, B, C). Humeral shaft fractures extending to the proximal or distal shaft, small or deformed medullary canal or open growth plate. Humeral shaft fractures with primary radial nerve palsy. Proximal humeral shaft fractures extending to the humeral head. Distal humeral fractures extending to the elbow joint. Two incisions proximal and distal to the fracture zone are used. A 3-cm proximal incision lies between the lateral border of the proximal part of the biceps and the medial border of the deltoid. Distally, a 3-cm incision is made along the lateral border of the biceps. The interval between biceps and brachialis is identified. The biceps is retracted medially to expose the musculocutaneous nerve. The brachialis muscle has dual innervation, the medial half being innervated by the musculocutaneous nerve and the lateral half by the radial nerve. The brachialis is split longitudinally at its midline. The musculocutaneous nerve is retracted along with the medial half of the brachialis, while the lateral half of the brachialis serves as a cushion to protect the radial nerve. A deep subbrachial tunnel is created from the distal to the proximal incision. The selected plate is tied with a suture to a hole at the tip of the tunneling instrument for pulling the plate back along the prepared track. The plate is aligned in the correct position on the anterior surface of the humerus. Traction is applied and the fracture reduced to restore alignment by image intensifier, followed by plate fixation with at least two bicortical locking screws or three bicortical

  1. Clinical cone beam computed tomography compared to high-resolution peripheral computed tomography in the assessment of distal radius bone.

    Science.gov (United States)

    de Charry, C; Boutroy, S; Ellouz, R; Duboeuf, F; Chapurlat, R; Follet, H; Pialat, J B

    2016-10-01

    Clinical cone beam computed tomography (CBCT) was compared to high-resolution peripheral quantitative computed tomography (HR-pQCT) for the assessment of ex vivo radii. Strong correlations were found for geometry, volumetric density, and trabecular structure. Using CBCT, bone architecture assessment was feasible but compared to HR-pQCT, trabecular parameters were overestimated whereas cortical ones were underestimated. HR-pQCT is the most widely used technique to assess bone microarchitecture in vivo. Yet, this technology has been only applicable at peripheral sites, in only few research centers. Clinical CBCT is more widely available but quantitative assessment of the bone structure is usually not performed. We aimed to compare the assessment of bone structure with CBCT (NewTom 5G, QR, Verona, Italy) and HR-pQCT (XtremeCT, Scanco Medical AG, Brüttisellen, Switzerland). Twenty-four distal radius specimens were scanned with these two devices with a reconstructed voxel size of 75 μm for Newtom 5G and 82 μm for XtremeCT, respectively. A rescaling-registration scheme was used to define the common volume of interest. Cortical and trabecular compartments were separated using a semiautomated double contouring method. Density and microstructure were assessed with the HR-pQCT software on both modality images. Strong correlations were found for geometry parameters (r = 0.98-0.99), volumetric density (r = 0.91-0.99), and trabecular structure (r = 0.94-0.99), all p < 0.001. Correlations were lower for cortical microstructure (r = 0.80-0.89), p < 0.001. However, absolute differences were observed between modalities for all parameters, with an overestimation of the trabecular structure (trabecular number, 1.62 ± 0.37 vs. 1.47 ± 0.36 mm(-1)) and an underestimation of the cortical microstructure (cortical porosity, 3.3 ± 1.3 vs. 4.4 ± 1.4 %) assessed on CBCT images compared to HR-pQCT images. Clinical CBCT devices are able to

  2. Rare stress fracture: longitudinal fracture of the femur.

    Science.gov (United States)

    Pérez González, M; Velázquez Fragua, P; López Miralles, E; Abad Moretón, M M

    42-year-old man with pain in the posterolateral region of the right knee that began while he was running. Initially, it was diagnosed by magnetic resonance (MR) as a possible aggressive process (osteosarcoma or Ewing's sarcoma) but with computed tomography it was noted a cortical hypodense linear longitudinal image with a continuous, homogeneous and solid periosteal reaction without clear soft tissue mass that in this patient suggest a longitudinal distal femoral fatigue stress fracture. This type of fracture at this location is very rare. Stress fractures are entities that can be confused with an agressive process. MR iscurrently the most sensitive and specific imaging method for its diagnosis. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Retrograde nail for tibiotalocalcaneal arthrodesis as a limb salvage procedure for open distal tibia and talus fractures with severe bone loss.

    Science.gov (United States)

    Ochman, Sabine; Evers, Julia; Raschke, Michael J; Vordemvenne, Thomas

    2012-01-01

    The treatment of complex fractures of the distal tibia, ankle, and talus with soft tissue damage, bone loss, and nonreconstructable joints for which the optimal timing for reduction and fixation has been missed is challenging. In such cases primary arthrodesis might be a treatment option. We report a series of multi-injured patients with severe soft tissue damage and bone loss, who were treated with a retrograde tibiotalocalcaneal arthrodesis nail as a minimally invasive treatment option for limb salvage. After a median follow-up of 5.4 years, all patients returned to their former profession. The ankle and bone fusion was complete, with moderate functional results and quality of life. Calcaneotibial arthrodesis using a retrograde nail is a good treatment option for nonreconstructable fractures of the ankle joint with severe bone loss and poor soft tissue quality in selected patients with multiple injuries, in particular, those involving both lower extremities, as a salvage procedure. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Utility of radius bone densitometry for the treatment of osteoporosis with once-weekly teriparatide therapy

    Directory of Open Access Journals (Sweden)

    Harumi Nakayama

    2018-03-01

    Full Text Available Objectives: As clinics that treat patients with osteoporosis do not usually have central dual-energy X-ray absorptiometry (DXA, bone density is often measured with radial DXA. However, no long-term evidence exists for radius bone density outcomes following treatment with once-weekly teriparatide in actual medical treatment. Methods: We evaluated changes in bone density at 6-, 12-, and 18-month intervals using radial DXA in patients treated with once-weekly teriparatide for more than 6 months. Results: A significant increase in bone mineral density (BMD was observed at the 1/3 and 1/10 radius sites 12 months after the initiation of once-weekly teriparatide. We also observed that the rate of change in BMD was greater at the distal 1/10 radius than at the 1/3 radius. Conclusions: Considering these points, the effect of once-weekly teriparatide therapy can be observed at the radius. In clinics that do not have central DXA, but instead have radial DXA, these findings can help to evaluate the effect of once-weekly teriparatide treatment on osteoporosis. Keywords: Once-weekly teriparatide, Osteoporosis, Radius, Dual-energy X-ray absorptiometry

  5. Short-term effects of teriparatide versus placebo on bone biomarkers, structure, and fracture healing in women with lower-extremity stress fractures: A pilot study.

    Science.gov (United States)

    Almirol, Ellen A; Chi, Lisa Y; Khurana, Bharti; Hurwitz, Shelley; Bluman, Eric M; Chiodo, Christopher; Matzkin, Elizabeth; Baima, Jennifer; LeBoff, Meryl S

    2016-09-01

    In this pilot, placebo-controlled study, we evaluated whether brief administration of teriparatide (TPTD) in premenopausal women with lower-extremity stress fractures would increase markers of bone formation in advance of bone resorption, improve bone structure, and hasten fracture healing according to magnetic resonance imaging (MRI). Premenopausal women with acute lower-extremity stress fractures were randomized to injection of TPTD 20-µg subcutaneous (s.c.) (n = 6) or placebo s.c. (n = 7) for 8 weeks. Biomarkers for bone formation N-terminal propeptide of type I procollagen (P1NP) and osteocalcin (OC) and resorption collagen type-1 cross-linked C-telopeptide (CTX) and collagen type 1 cross-linked N-telopeptide (NTX) were measured at baseline, 4 and 8 weeks. The area between the percent change of P1NP and CTX over study duration is defined as the anabolic window. To assess structural changes, peripheral quantitative computed topography (pQCT) was measured at baseline, 8 and 12 weeks at the unaffected tibia and distal radius. The MRI of the affected bone assessed stress fracture healing at baseline and 8 weeks. After 8 weeks of treatment, bone biomarkers P1NP and OC increased more in the TPTD- versus placebo-treated group (both p ≤ 0.01), resulting in a marked anabolic window (p ≤ 0.05). Results from pQCT demonstrated that TPTD-treated women showed a larger cortical area and thickness compared to placebo at the weight bearing tibial site, while placebo-treated women had a greater total tibia and cortical density. No changes at the radial sites were observed between groups. According to MRI, 83.3% of the TPTD- and 57.1% of the placebo-treated group had improved or healed stress fractures (p = 0.18). In this randomized, pilot study, brief administration of TPTD showed anabolic effects that TPTD may help hasten fracture healing in premenopausal women with lower-extremity stress fractures. Larger prospective studies are warranted to determine

  6. Computer-assisted surgery for screw insertion into the distal sesamoid bone in horses: an in vitro study.

    Science.gov (United States)

    Gygax, Diego; Lischer, Christoph; Auer, Joerg A

    2006-10-01

    To compare the precision of computer-assisted surgery with a conventional technique (CV) using a special guiding device for screw insertion into the distal sesamoid bone in horses. In vitro experimental study. Cadaveric forelimb specimens. Insertion of a 3.5 mm cortex screw in lag fashion along the longitudinal axis of intact (non-fractured) distal sesamoid bones was evaluated in 2 groups (8 limbs each): CV and computer-assisted surgery (CAS). For CV, the screw was inserted using a special guiding device and fluoroscopy, whereas for CAS, the screw was inserted using computer-assisted navigation. The accuracy of screw placement was verified by radiography, computed tomography, and specimen dissection. Surgical precision was better in CAS compared with CV. CAS improves the accuracy of lateromedial screw insertion, in lag fashion, into the distal sesamoid bone. The CAS technique should be considered for improved accuracy of screw insertion in fractures of the distal sesamoid bone.

  7. Arthroplasty of the distal ulna distal in managing patients with post-traumatic disorders of the distal radioulnar joint: measurement of quality of life

    Directory of Open Access Journals (Sweden)

    Marcio Aurélio Aita

    2015-12-01

    Full Text Available ABSTRACT OBJECTIVE: To measure the quality of life and clinical-functional results from patients diagnosed with osteoarthrosis of the distal radioulnar joint who underwent surgical treatment using the technique of total arthroplasty of the ulna, with a total or partial Ascension(r prosthesis of the distal ulna. METHODS: Ten patients were evaluated after 12 months of follow-up subsequent to total or partial arthroplasty of the distal ulna. All of them presented post-traumatic osteoarthrosis and/or chronic symptomatic instability of the distal radioulnar joint. The study was prospective. Seven patients had previously undergone wrist procedures (two cases with Darrach, three with Sauvé-Kapandji and two with ligament reconstruction of the fibrocartilage complex and three presented fractures of the distal ulna that evolved with pain, instability and osteoarthrosis of the distal radioulnar joint. The following were assessed: quality of life (DASH scale; percentage degree of palm grip strength (kgf and pronosupination range of motion in relation to the unaffected side; pain (VAS; return to work; subjective evaluation of radiography; and complications. RESULTS: The patients presented a mean range of motion of 174.5° (normal side: 180°. Quality of life was analyzed by applying the DASH questionnaire and the mean value found was 5.9. The mean pain score using the VAS was 2.3. The mean degree of palm grip strength (kgf was 50.7, which represented 90.7% of the strength on the unaffected side. The complication rate was 10%: this patient presented slight dorsal instability of the ulna and persistent pain, and did not return to work. This patient is still being followed up in the outpatient clinic and occupational therapy sector, with little improvement. He does not wish to undergo a new procedure. The mean length of follow-up was 16.8 months, with a minimum of 10 and maximum of 36 months. CONCLUSION: This concept is subject to the test of time

  8. Femoral Neck Shaft Angle in Men with Fragility Fractures

    Directory of Open Access Journals (Sweden)

    S. P. Tuck

    2011-01-01

    Full Text Available Introduction. Femoral neck shaft angle (NSA has been reported to be an independent predictor of hip fracture risk in men. We aimed to assess the role of NSA in UK men. Methods. The NSA was measured manually from the DXA scan printout in men with hip (62, 31 femoral neck and 31 trochanteric, symptomatic vertebral (91, and distal forearm (67 fractures and 389 age-matched control subjects. Age, height, weight, and BMD (g/cm2: lumbar spine, femoral neck, and total femur measurements were performed. Results. There was no significant difference in mean NSA between men with femoral neck and trochanteric hip fractures, so all further analyses of hip fractures utilised the combined data. There was no difference in NSA between those with hip fractures and those without (either using the combined data or analysing trochanteric and femoral neck shaft fractures separately, nor between fracture subjects as a whole and controls. Mean NSA was smaller in those with vertebral fractures (129.2° versus 131°: P=0.001, but larger in those with distal forearm fractures (129.8° versus 128.5°: P=0.01. Conclusions. The conflicting results suggest that femoral NSA is not an important determinant of hip fracture risk in UK men.

  9. Role of MRI in the diagnosis and management of patients with clinical scaphoid fracture.

    Science.gov (United States)

    Tibrewal, Saket; Jayakumar, Prakash; Vaidya, Sujit; Ang, Swee Chai

    2012-01-01

    The American College of Radiologists (ACR) recognises the value of magnetic resonance imaging (MRI) as the investigation of choice in patients with a clinically suspected scaphoid fracture but normal plain radiographs. The Royal College of Radiologists (RCR) in the UK produces no similar guidelines, as evidenced by the inconsistent management of such cases in hospitals around the UK. In discussion with our musculoskeletal radiologists, we implemented new guidelines to standardise management of our patients and now report our findings. A consecutive series of 137 patients referred to the orthopaedic department with clinically suspected scaphoid fracture but normal series of plain radiographs were prospectively followed up over a two-year period. We implemented the use of early MRI for these patients and determined its incidence of detected scaphoid injury in addition to other occult injuries. We then prospectively examined results of these findings on patient management. Thirty-seven (27%) MRI examinations were normal with no evidence of a bony or soft-tissue injury. Soft-tissue injury was diagnosed in 59 patients (43.4%). Of those, 46 were triangular fibrocartilage complex (TFCC) tears (33.8%) and 18 were intercarpal ligament injuries (13.2 %). Bone marrow oedema with no distinct fracture was discovered in 55 cases (40.4%). In 17 (12.5%) cases, this involved only the scaphoid. In the remainder, it also involved the other carpal bones or distal radius. Fracture(s) were diagnosed on 30 examinations (22.0%). MRI should be regarded as the gold standard investigation for patients in whom a scaphoid fracture is suspected clinically. It allows the diagnosis of occult bony and soft-tissue injuries that can present clinically as a scaphoid fracture; it also helps exclude patients with no fracture. We believe that there is a need to implement national guidelines for managing occult scaphoid fractures.

  10. Navicular bone fracture in the pelvic limb in two horses

    International Nuclear Information System (INIS)

    Kaser-Hotz, B.; Ueltschi, G.; Hess, N.

    1991-01-01

    The case history, radiographic and scintigraphic findings of two horses with pelvic limb navicular bone fractures are presented. In both cases the fractures were of traumatic origin. One horse had a bilateral fracture of the navicular bone, distal border, the other horse had a fracture of the proximal articular border in one pelvic limb navicular bone

  11. Effect of a new formulation of micronized and ultramicronized N-palmitoylethanolamine in a tibia fracture mouse model of complex regional pain syndrome.

    Directory of Open Access Journals (Sweden)

    Roberta Fusco

    Full Text Available Complex regional pain syndrome type 1 (CRPS-I is a disabling and frequently chronic condition. It involves the extremities and is a frequent consequence of distal tibia and radius fractures. The inflamed appearance of the affected CRPS-I limb suggests that local production of inflammatory mediators may be implicated in the ensuing etiology. A rodent tibia fracture model, characterized by inflammation, chronic unilateral hindlimb warmth, edema, protein extravasation, allodynia and hyperalgesia resembles the clinical features of patients with acute CRPS-I. N-palmitoylethanolamine (PEA, a member of the family of naturally-occurring N-acylethanolamines, is well-known for its ability to modulate inflammatory processes and regulate pain sensitivity. However, the large particle size and lipidic nature of PEA may limit its bioavailability and solubility when given orally. Micronized formulations are frequently used to enhance the dissolution rate of drug and reduce its variability of absorption when orally administered. The aim of this study was to assess the effects of a formulation of micronized and ultramicronized PEA (PEA-MPS, given orally in a mouse model of CRPS-I. CD-1 male mice were subjected to distal tibia fracture and divided into two groups: control and treated with PEA-MPS (PEA micronized 300 mg/kg and ultramicronized 600 mg/kg. Sensibility to pain was monitored in all mice throughout the course of the experiment. Twenty-eight days after tibia fracture induction animals were sacrificed and biochemical parameters evaluated. The PEA-MPS-treated group showed an improved healing process, fracture recovery and fibrosis score. PEA-MPS administration decreased mast cell density, nerve growth factor, matrix metalloproteinase 9 and cytokine expression. This treatment also reduced (poly-ADPribose polymerase activation, peroxynitrite formation and apoptosis. Our results suggest that PEA-MPS may be a new therapeutic strategy in the treatment of CRPS-I.

  12. Pulsed electromagnetic field during cast immobilization in postmenopausal women with Colles’ fracture

    Directory of Open Access Journals (Sweden)

    Lazović Milica

    2012-01-01

    Full Text Available Introduction. Although Colles’ fracture i.e. a dorsally displaced distal radius fracture (DRF is one of the most common fractures, there is no enough evidence to determine the best form of rehabilitation. Objective. To assess whether the use of pulsed electromagnetic field (PEMF therapy during cast immobilization of DRF provides beneficial effects on pain, edema, wrist range of motion and function, as well as on the frequency of complications immediately after cast removal. Methods. The prospective randomized controlled study included 60 women over the age of 55 years with extra-articular displaced DRF treated with reduction and cast immobilization. The patients were alternately allocated to either a PEMF group (n=30, received 10 days of PEMF therapy during immobilization, or a control group (n=30, without PEMF therapy. Pain, function, hand circumference, wrist and forearm range of motion and frequency of complications for each patient was evaluated within two to three days of cast removal. Results. Better mean values for the majority of examined parameters were recorded in the PEMF group than in the control group, but the difference was statistically significant just for edema (p<0.001, flexion, extension and supination range (p<0.01. Conclusion. During immobilization PEMF therapy in DRF patients gave better results immediately after cast removal in terms of edema and wrist range of motion (ROM.

  13. Progress and prediction of occupational performance in women with distal radius fractures

    DEFF Research Database (Denmark)

    Nielsen, Tove Lise; Dekkers, Merete Klindt

    2013-01-01

    , and validated questions on pain. The number of performance problems fell from median 18 at cast removal to median 3 at 12 months. COPM performance and satisfaction scores improved significantly to 8.6 and 9.2 at 12 months. Also the DASH score improved significantly to 14.2 at 12 months. The largest improvements...

  14. Effect of physiotherapy in people with distal radius fractures: A systematic review

    Directory of Open Access Journals (Sweden)

    Claudia Liliana Moreno-Montoya

    2017-10-01

    Conclusion: Evidence suggests that supervised therapeutic interventions that include physical and exercise modalities lasting between 6 and 9 weeks, with an average of 18 sessions and three times a week, significantly improve the variables studied in patients with DRF. Future studies should establish the dose-response correlation of these interventions.

  15. The standardized creation of a lumbar spine vertebral compression fracture in a sheep osteoporosis model induced by ovariectomy, corticosteroid therapy and calcium/phosphorus/vitamin D-deficient diet.

    Science.gov (United States)

    Eschler, Anica; Röpenack, Paula; Herlyn, Philipp K E; Roesner, Jan; Pille, Kristin; Büsing, Kirsten; Vollmar, Brigitte; Mittlmeier, Thomas; Gradl, Georg

    2015-10-01

    Vertebral compression fractures (VCFs) are one of the most common injuries in the aging population presenting with an annual incidence of 1.4 million new cases in Europe. Current treatment strategies focus on cement-associated solutions (kyphoplasty/vertebroplasty techniques). Specific cement-associated problems as leakage, embolism and the adjacent fracture disease are reported adding to open questions like general fracture healing properties of the osteoporotic spine. In order to analyze those queries animal models are of great interest; however, both technical difficulties in the induction of experimental osteoporosis in animal as well as the lack of a standardized fracture model impede current and future in vivo studies. This study introduces a standardized animal model of an osteoporotic VCF type A3.1 that may enable further in-depth analysis of the afore mentioned topics. Twenty-four 5-year-old female Merino sheep (mean body weight: 67 kg; range 57-79) were ovariectomized (OP1) and underwent 5.5 months of weekly corticosteroid injections (dexamethasone and dexamethasone-sodium-phosphate), adding to a calcium/phosphorus/vitamin D-deficient diet. Osteoporosis induction was documented by pQCT and micro-CT BMD (bone mineral density) as well as 3D histomorphometric analysis postoperatively of the sheep distal radius and spine. Non osteoporotic sheep served as controls. Induction of a VCF of the second lumbar vertebra was performed via a mini-lumbotomy surgical approach with a standardized manual compression mode (OP2). PQCT analysis revealed osteoporosis of the distal radius with significantly reduced BMD values (0.19 g/cm(3), range 0.13-0.22 vs. 0.27 g/cm(3), range 0.23-0.32). Micro-CT documented significant lowering of BMD values for the second lumbar vertebrae (0.11 g/cm(3), range 0.10-0.12) in comparison to the control group (0.14 g/cm(3), range 0.12-0.17). An incomplete burst fracture type A3.1 was achieved in all cases and resulted in a significant decrease

  16. Is Fibular Fracture Displacement Consistent with Tibiotalar Displacement?

    NARCIS (Netherlands)

    van den Bekerom, Michel P. J.; van Dijk, C. Niek

    2010-01-01

    We believed open reduction with internal fixation is required for supination-external rotation ankle fractures located at the level of the distal tibiofibular syndesmosis (Lauge-Hanssen SER II and Weber B) with 2 mm or more fibular fracture displacement. The rationale for surgery for these ankle

  17. Use of a modified transfixation pin cast for treatment of comminuted phalangeal fractures in horses.

    Science.gov (United States)

    Rossignol, Fabrice; Vitte, Amélie; Boening, Josef

    2014-01-01

    To (1) report a modified transfixation pin cast technique, using dorsal recumbency for fracture reduction, distal positioning of the pins in the epiphysis and distal metaphysis, and a hybrid cast, combining plaster of Paris (POP) and fiberglass casting, and (2) report outcome in 11 adult horses. Case series. Adult horses (n = 11) with comminuted phalangeal fractures. Horses were anesthetized and positioned in dorsal recumbency. The phalangeal fracture was reduced by limb traction using a cable attached to the hoof. Screw fixation in lag fashion of fracture fragments was performed when possible. Transfixation casting was performed using two 6.3 mm positive profile centrally threaded pins with the 1st pin placed in the epiphysis of the metacarpus/tarsus at the center of, or slightly proximal to, the condylar fossa and the 2nd one 3-4 cm proximal. A hybrid cast was applied. Forelimbs were involved in 9 horses and the hind limb in 2. Pins were maintained for a minimum of 6 weeks. No pin loosening was observed at the time of removal (6-8 weeks). A pony fractured the distal aspect of the metacarpus at the proximal pin. Nine horses survived (82%); none of the horses developed septic arthritis despite the distal location of the distal pin, close to the fetlock joint. This modified transfixation pin casting technique was associated with good pin longevity and could reduce the risk of secondary pin hole fractures and pin loosening. © Copyright 2013 by The American College of Veterinary Surgeons.

  18. Evaluation of scale effects on hydraulic characteristics of fractured rock using fracture network model

    International Nuclear Information System (INIS)

    Ijiri, Yuji; Sawada, Atsushi; Uchida, Masahiro; Ishiguro, Katsuhiko; Umeki, Hiroyuki; Sakamoto, Kazuhiko; Ohnishi, Yuzo

    2001-01-01

    It is important to take into account scale effects on fracture geometry if the modeling scale is much larger than the in-situ observation scale. The scale effect on fracture trace length, which is the most scale dependent parameter, is investigated using fracture maps obtained at various scales in tunnel and dam sites. We found that the distribution of fracture trace length follows negative power law distribution in regardless of locations and rock types. The hydraulic characteristics of fractured rock is also investigated by numerical analysis of discrete fracture network (DFN) model where power law distribution of fracture radius is adopted. We found that as the exponent of power law distribution become larger, the hydraulic conductivity of DFN model increases and the travel time in DFN model decreases. (author)

  19. Multiple bilateral lower limb fractures in a 2-year-old child: previously unreported injury with a unique mechanism

    Directory of Open Access Journals (Sweden)

    Anuj Jain

    2014-10-01

    Full Text Available 【Abstract】Fall from height is a common cause of unintentional injuries in children and accounts for 6% of all trauma-related childhood deaths, usually from head injury. We report a case of a 2-year-old child with multiple fractures of the bilateral lower limbs due to this reason. A child fell from a height of around 15 feet after toppling from a alcony. He developed multiple fractures involving the right femoral shaft, right distal femoral epiphysis (Salter Harris type 2, right distal metaphysis of the tibia and fi bula, and undisplaced Salter Harris type 2 epiphyseal injury of the left distal tibia. There were no head, abdominal or spinal injuries. The patient was taken into emergency operation theatre after initial management which consisted of intravenous fl uids, blood transfusion, and splintage of both lower limbs. Fracture of the femoral shaft was treated by closed reduction and fixation using two titanium elastic nails. Distal femoral physeal injury required open eduction and fixation with K wires. Distal tibia fractures were closely reduced and managed nonoperatively in both the lower limbs. All the fractures united in four weeks. At the last follow-up, the child had no disability and was able to perform daily ctivities comfortably. We also proposed the unique mechanism of injury in this report. Key words: Multiple bilateral lower limb fractures; Fall; Child

  20. Tibiofibula Transposition in High-Energy Fractures

    Directory of Open Access Journals (Sweden)

    Peter R. Loughenbury

    2016-01-01

    Full Text Available We report two cases of failed attempts at closed reduction of high-energy tibial fractures with an associated fibula fracture. The first case was a 39-year-old male involved in high-speed motorbike collision, while the second was a 14-year-old male who injured his leg following a fall of three metres. Emergency medical services at the scenes of the accidents reported a 90-degree valgus deformity of the injured limb and both limbs were realigned on scene and stabilized. Adequate alignment of the tibia could not be achieved by manipulation under sedation or anaesthesia. Open reduction and exposure of the fracture sites revealed that the distal fibula fragment was “transposed” and entrapped in the medulla of the proximal tibial fragment. Reduction required simulation of the mechanism of injury in order to disengage the fragments and allow reduction. Tibiofibula transposition is a rare complication of high-energy lower limb fractures which has not previously been reported and may prevent adequate closed reduction. Impaction of the distal fibula within the tibial medulla occurs as the limb is realigned by paramedic staff before transfer to hospital. We recommend that when this complication is identified the patient is transferred to the operating room for open reduction and stabilization of the fracture.

  1. A Misdiagnosis of Traumatic Hypersupination of the Distal Radioulnar Joint: A Case Report

    Directory of Open Access Journals (Sweden)

    Vipin Asopa

    2013-01-01

    Full Text Available Traumatic hypersupination injury of the distal radioulnar joint is a rare injury, and occurs when sufficient supination force is applied to the joint so as to tear the volar radioulnar ligament, resulting in separation of the triangular fibrocartilage complex, and subluxation of the tendon of extensor carpi ulnaris. This allows the distal ulna to rotate such that the ulnar styloid comes to lie adjacent to the ulna notch of the radius. Treatment of this injury requires manipulation of the joint, under anaesthesia or sedation. We describe a case where posttraumatic radiological investigation of a patient with an anatomical variation of the wrist when in supination resembled a traumatic hypersupination injury of the distal radioulnar joint. A review of the literature has revealed this to be the first reported case of this type.

  2. [Kirschner wire osteosynthesis for fractures in childhood: bury wires or not? : Results of a survey on care reality in Germany].

    Science.gov (United States)

    Schneidmueller, D; Kertai, M; Bühren, V; von Rüden, C

    2018-02-20

    Kirschner wire osteosynthesis is considered to be the standard technique for surgical fixation of displaced supracondylar humeral and distal radial fractures in children. The Kirschner wires can be left exposed or buried under the skin. Advantages of the epicutaneous technique are, e. g. the efficiency (cost, effort) and the possibility for wire removal without the necessity of a second anesthesia. On the other hand, there is a concern about higher infection rates as well as traumatization of the children due to externally visible wires. A web-based survey of members of the DGU, DGOU, DGOOC, and the pediatric traumatology section of the DGU (SKT) was performed to evaluate current treatment concepts in Germany. The pros and cons for each technique were recorded and the need for a clinical study was examined. In addition, a cost analysis was performed for both methods. The results from the literature are summarized and discussed. A total of 710 questionnaires were evaluated. The majority of the respondents were trauma surgeons working in a hospital (80%). The buried technique was superior in both fracture groups (supracondylar humeral fractures 73% and distal radius fractures 69%), whereas a relevant difference could be found depending on the profession. The main reason for the subcutaneous technique was anxiety or observed higher infections using the epicutaneous technique. In Germany, the majority of wires are buried under the skin due to a fear of higher infection rates. In addition, other influencing factors such as pain and traditional approaches play a significant role. With respect to the results in the literature as well as a possible improvement of efficiency and avoidance of a second anesthesia, a multicentric clinical study seems necessary in the future to compare both techniques.

  3. Use of MR-based trabecular bone microstructure analysis at the distal radius for osteoporosis diagnostics: a study in post-menopausal women with breast cancer and treated with aromatase inhibitor.

    Science.gov (United States)

    Baum, Thomas; Karampinos, Dimitrios C; Seifert-Klauss, Vanadin; Pencheva, Tsvetelina D; Jungmann, Pia M; Rummeny, Ernst J; Müller, Dirk; Bauer, Jan S

    2016-01-01

    Treatment with aromatase inhibitor (AI) is recommended for post-menopausal women with hormone-receptor positive breast cancer. However, AI therapy is known to induce bone loss leading to osteoporosis with an increased risk for fragility fractures. The purpose of this study was to investigate whether changes of magnetic resonance (MR)-based trabecular bone microstructure parameters as advanced imaging biomarker can already be detected in subjects with AI intake but still without evidence for osteoporosis according to dual energy X-ray absorptiometry (DXA)-based bone mineral density (BMD) measurements as current clinical gold standard. Twenty-one postmenopausal women (62±6 years of age) with hormone-receptor positive breast cancer, ongoing treatment with aromatase inhibitor for 23±15 months, and no evidence for osteoporosis (current DXA T-score greater than -2.5) were recruited for this study. Eight young, healthy women (24±2 years of age) were included as controls. All subjects underwent 3 Tesla magnetic resonance imaging (MRI) of the distal radius to assess the trabecular bone microstructure. Trabecular bone microstructure parameters were not significantly (p>0.05) different between subjects with AI intake and controls, including apparent bone fraction (0.42±0.03 vs. 0.42±0.05), trabecular number (1.95±0.10 mm(-1) vs 1.89±0.15 mm(-1)), trabecular separation (0.30±0.03 mm vs 0.31±0.06 mm), trabecular thickness (0.21±0.01 mm vs 0.22±0.02 mm), and fractal dimension (1.70±0.02 vs. 1.70±0.03). These findings suggest that the initial deterioration of trabecular bone microstructure as measured by MRI and BMD loss as measured by DXA occur not sequentially but rather simultaneously. Thus, the use of MR-based trabecular bone microstructure assessment is limited as early diagnostic biomarker in this clinical setting.

  4. Fracture analysis of randomized implant-supported fixed dental prostheses

    Science.gov (United States)

    Esquivel-Upshaw, Josephine F.; Mehler, Alex; Clark, Arthur E.; Neal, Dan; Anusavice, Kenneth J.

    2014-01-01

    Objective Fractures of posterior fixed dental all-ceramic prostheses can be caused by one or more factors including prosthesis design, flaw distribution, direction and magnitude of occlusal loading, and nature of supporting infrastructure (tooth root/implant), and presence of adjacent teeth. This clinical study of implant-supported, all-ceramic fixed dental prostheses, determined the effects of (1) presence of a tooth distal to the most distal retainer; (2) prosthesis loading either along the non-load bearing or load bearing areas; (3) presence of excursive contacts or maximum intercuspation contacts in the prosthesis; and (4) magnitude of bite force on the occurrence of veneer ceramic fracture. Methods 89 implant-supported FDPs were randomized as either a three-unit posterior metal-ceramic (Au-Pd-Ag alloy and InLine POM, Ivoclar, Vivadent) FDP or a ceramic-ceramic (ZirCAD and ZirPress, Ivoclar, Vivadent) FDP. Two implants (Osseospeed, Dentsply) and custom abutments (Atlantis, Dentsply) supported these FDPs, which were cemented with resin cement (RelyX Universal Cement). Baseline photographs were made with markings of teeth from maximum intercuspation (MI) and excursive function. Patients were recalled at 6 months and 1 to 3 years. Fractures were observed, their locations recorded, and images compared with baseline photographs of occlusal contacts. Conclusion No significant relationship exists between the occurrence of fracture and: (1) the magnitude of bite force; (2) a tooth distal to the most distal retainer; and (3) contacts in load-bearing or non-load-bearing areas. However, there was a significantly higher likelihood of fracture in areas with MI contacts only. Clinical Significance This clinical study demonstrates that there is a need to evaluate occlusion differently with implant-supported prostheses than with natural tooth supported prostheses because of the absence of a periodontal ligament. Implant supported prostheses should have minimal occlusion and

  5. Medial joint space widening of the ankle in displaced Tillaux and Triplane fractures in children.

    Science.gov (United States)

    Gourineni, Prasad; Gupta, Asheesh

    2011-10-01

    Tillaux and Triplane fractures occur in children predominantly from external rotation mechanism. We hypothesized that in displaced fractures, the talus would shift laterally along with the distal fibula and the distal tibial epiphyseal fragment increasing the medial joint space. Consecutive cases evaluated retrospectively. Level I and Level II centers. Twenty-two skeletally immature patients with 14 displaced Triplane fractures and eight displaced Tillaux fractures were evaluated for medial joint space widening. Measurement of fracture displacement and medial joint space widening before and after intervention. Thirteen Triplane and six Tillaux fractures (86%) showed medial space widening of 1 to 9 mm and equal to the amount of fracture displacement. Reduction of the fracture reduced the medial space to normal. There were no known complications. Medial space widening of the ankle may be a sign of ankle fracture displacement. Anatomic reduction of the fracture reduces the medial space and may improve the results in Tillaux and Triplane fractures.

  6. Is Hardware Removal Recommended after Ankle Fracture Repair?

    Directory of Open Access Journals (Sweden)

    Hong-Geun Jung

    2016-01-01

    Full Text Available The indications and clinical necessity for routine hardware removal after treating ankle or distal tibia fracture with open reduction and internal fixation are disputed even when hardware-related pain is insignificant. Thus, we determined the clinical effects of routine hardware removal irrespective of the degree of hardware-related pain, especially in the perspective of patients’ daily activities. This study was conducted on 80 consecutive cases (78 patients treated by surgery and hardware removal after bony union. There were 56 ankle and 24 distal tibia fractures. The hardware-related pain, ankle joint stiffness, discomfort on ambulation, and patient satisfaction were evaluated before and at least 6 months after hardware removal. Pain score before hardware removal was 3.4 (range 0 to 6 and decreased to 1.3 (range 0 to 6 after removal. 58 (72.5% patients experienced improved ankle stiffness and 65 (81.3% less discomfort while walking on uneven ground and 63 (80.8% patients were satisfied with hardware removal. These results suggest that routine hardware removal after ankle or distal tibia fracture could ameliorate hardware-related pain and improves daily activities and patient satisfaction even when the hardware-related pain is minimal.

  7. Epidemiology of forearm fractures in adults in Denmark

    DEFF Research Database (Denmark)

    Abrahamsen, Bo; Jørgensen, N R; Schwarz, P

    2015-01-01

    with less detailed information. Rates were higher than previously estimated. INTRODUCTION: Despite a significant contribution to the overall burden of osteoporotic, nonvertebral fractures, relatively little information is available about age- and gender-specific incidence rates for many countries including...... Denmark. METHODS: We used national individual patient data on inpatient and outpatient treatment to calculate rates of forearm fractures, taking readmissions into account, with subtables for distal and proximal fractures. We also calculated ratios of forearm to hip fractures that may be useful when...

  8. Computer simulation of ductile fracture

    International Nuclear Information System (INIS)

    Wilkins, M.L.; Streit, R.D.

    1979-01-01

    Finite difference computer simulation programs are capable of very accurate solutions to problems in plasticity with large deformations and rotation. This opens the possibility of developing models of ductile fracture by correlating experiments with equivalent computer simulations. Selected experiments were done to emphasize different aspects of the model. A difficult problem is the establishment of a fracture-size effect. This paper is a study of the strain field around notched tensile specimens of aluminum 6061-T651. A series of geometrically scaled specimens are tested to fracture. The scaled experiments are conducted for different notch radius-to-diameter ratios. The strains at fracture are determined from computer simulations. An estimate is made of the fracture-size effect

  9. A comparison of radiography, computed tomography, and magnetic resonance imaging for the diagnosis of palmar process fractures in foals

    International Nuclear Information System (INIS)

    Kaneps, A.J.; Koblik, P.D.; Freeman, D.M.; Pool, R.R.; O'Brien, T.R.

    1995-01-01

    The relative sensitivity of radiography, computed tomography, and magnetic resonance imaging for detecting palmar process fractures of the distal phalanx in foals was determined and the imaging findings were compared with histomorphologic evaluations of the palmar processes. Compared to radiography, computed tomography and magnetic resonance imaging did not improve the sensitivity for detection of palmar process fractures. Statistical agreement for palmar process fracture diagnosis was excellent among the three imaging modalities. Histomorphologic evaluations were more sensitive for diagnosis of palmar process fracture than any of the imaging modalities. Three-dimensional image reconstructions and volume measurements of distal phalanges and palmar process fracture fragments from computed tomography studies provided more complete anatomical information than radiography. Magnetic resonance imaging confirmed that the deep digital flexor tendon insertion on the distal phalanx is immediately axial to the site where palmar process fractures occur, and differentiated cartilage, bone, and soft tissue structures of the hoof

  10. Association between distal ulnar morphology and extensor carpi ulnaris tendon pathology

    International Nuclear Information System (INIS)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Kattapuram, Susan V.; Torriani, Martin

    2014-01-01

    The purpose of this study was to evaluate the association between distal ulnar morphology and extensor carpi ulnaris (ECU) tendon pathology. We retrospectively reviewed 71 adult wrist MRI studies with ECU tendon pathology (tenosynovitis, tendinopathy, or tear), and/or ECU subluxation. Subjects did not have a history of trauma, surgery, infection, or inflammatory arthritis. MRI studies from 46 subjects without ECU tendon pathology or subluxation were used as controls. The following morphological parameters of the distal ulna were measured independently by two readers: ulnar variance relative to radius, ulnar styloid process length, ECU groove depth and length. Subjects and controls were compared using Student's t test. Inter-observer agreement (ICC) was calculated. There was a significant correlation between negative ulnar variance and ECU tendon pathology (reader 1 [R1], P = 0.01; reader 2 [R2], P 0.64 for all parameters. Distal ulnar morphology may be associated with ECU tendon abnormalities. (orig.)

  11. Osseous Anatomy of the Distal Radioulnar Joint: An Assessment Using 3-Dimensional Modeling and Clinical Implications.

    Science.gov (United States)

    Daneshvar, Parham; Willing, Ryan; Pahuta, Markian; Grewal, Ruby; King, Graham J W

    2016-11-01

    Using a novel technique, we assess and describe the distal radioulnar joint (DRUJ) anatomy. The purpose of this study was to provide the anatomic dimensions of the DRUJ and to evaluate contralateral symmetry. Computed tomography images of 100 cadaveric forearms were obtained. Three-dimensional models of the radius and ulna were generated and evaluated using 3-dimensional modeling software. Measurements of the radius of curvature of the sigmoid notch (SN) and ulnar head (UH), as well as the length of the SN and volar and dorsal lips were performed in the axial and coronal sequences. In addition, mid-coronal angular measurements were made of the SN and UH to quantify the obliquity of the DRUJ. All coronal measurements were performed with the forearm set to neutral rotation. The average ulnar variance was -0.9 ± 1.8 mm. The radius of curvature of the UH (8.2 ± 1.3 mm) was markedly smaller than that of the SN (18.2 ± 8.5 mm). The length of the SN in coronal sequences increased from volar to dorsal by 65%. The mid-coronal angle (DRUJ obliquity) of the SN and UH measured 6.0 ± 9.9° and 18.0 ± 9.9°, respectively. A direct inverse correlation was demonstrated in the obliquity of the DRUJ and ulnar variance. All anatomic measurements were similar when comparing bilateral specimens. The SN length tends to increase in size from volar to dorsal. Bilateral specimens from the same individual demonstrate similarities and can be cautiously used for comparison. The relationships and measurements demonstrated in this study can be a guide when considering reconstructive procedures or dealing with complex fractures involving the DRUJ. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  12. Angular deformation of radius and ulna treated by dynamic percutaneus osteogenesis distraction. Case report

    International Nuclear Information System (INIS)

    Rezende, C.M.F.; Melo, E.G.; Lamas, M.C.S.; Silva, C.A.

    2000-01-01

    The clinical exam of a male mongrel dog, 4-month-old, and 5.7kg of live weight, showed that the dog supported with the elbows and it was observed accentuated bilateral rotacional deformity of the radius and ulna. Radiographs of the radius and ulna revealed proximal fracture of the radius. After clinical and radiographic evaluation it was indicated the corrective osteotomy and distraction osteogenesis of the left foremember. The surgical procedure consisted in osteotomy in the diaphysis of the radius and ulna, and the utilization of external fixators composed by four Kirschner’s pins and two metallic thread bars, configuring a fixator type II, bilateral uniplanar dynamic. Before the fixation of the pins with acrylic, the fractured bony fragments were separated in approximately 0.5cm. Starting 10 days post surgery, the radial osteotomy site was distracted at a rate of 1.0mm every day for 30 days. The consolidation of the osteotomy site was observed radiographically 67 days after the intervention, when the fixator was removed. Similar procedure was accomplished in the right foremember at the age of 16 months. At this moment, it was necessary to remove a coins bony of approximately 1.0cm for correction of the limb angulation. At present, the dog shows normal function and support of the left foremember and light valgus deformity of the right foremember due to the broken implants [pt

  13. AN EPIDEMIOLOGICAL SURVEY OF OSTEOPOROTIC FRACTURES IN OLDER RESIDENTS FROM THE MIDDLE URALS

    Directory of Open Access Journals (Sweden)

    E. N. Gladkova

    2014-01-01

    Full Text Available The epidemiological characteristics of osteoporotic fractures in Russia have been inadequately studied.Objective: to estimate the incidence rate of osteoporotic fractures in the old age groups of an urban population in the Middle Urals.Subjects and methods. The survey was performed in Pervouralsk, a typical industrial town in the Middle Urals, with a total of 160,860 people, including 54,189 dwellers over 50 years of age (20,746 men and 33,443 women, which amounted to 33.7% of the general population of the town. The survey covered its residents aged 50 years and over who had fractures of the proximal hip (FPH, distal forearm (FDF, distal shin, ribs, or surgical neck of the humerusbetween 1 January 2008 and 31 December 2009. Statistical analysis was made applying the programs Biostatistics, Microsoft Excell 2007, and MedCalc (demo-version. The findings were processed using parametric and nonparametric statistical methods.Results. During two years, 1371 fractures, including FPH, FDF, fractures of the humerus, distal shin, and ribs, were registered in the examined sample of persons aged 50 years and over from Pervouralsk. 383 (27.9% of these fractures occurred in men and 988 (72.1% in women. The incidence rate of all fractures was 1265.0 per 100,000 inhabitants aged 50 years and over (1,477.1 for women and 923.1 for men. FDF were more common in women, the incidence was 787.9 cases per 100,000 population; costal fractures – in men (386.7 per 100,000. The investigation has shown that certain types of fractures are predominant in the oldest age groups. Thus, the incidence rate of FDF and fractures of the distal shin decreases while that of FPH and fractures of the humerus increaseswith age, which is likely to be due to several causes: an age-related decline in bone mass; an increase in the frequency of falls with age; muscle weakness and movement discoordination, which alter the mechanism of fall and increase the risk of femoral and

  14. Two new methods for the determination of hydraulic fracture ...

    African Journals Online (AJOL)

    2008-09-15

    Sep 15, 2008 ... Flow is radial and divergent. • There is only a single fracture within the test segment. • The fracture and rock mass are rigid and the matrix is imper- meable. • The fracture aperture varies along the radius and is radically symmetrical about the borehole. • Advection, dispersion and diffusion are negligible due ...

  15. Anatomic relationships of the distal and proximal radioulnar joints articulating surface areas, and of the radius and ulna bone volumes – implications for biomechanical studies of the distal and proximal radioulnar joints and forearm bones

    Directory of Open Access Journals (Sweden)

    Paul S C Malone

    2016-07-01

    Full Text Available BackgroundPrevious work from this laboratory has evidenced the biomechanical role of forearm osseoligamentous structures in load transfer of applied forces. It has shown that transmitted forces across the distal radioulnar joint (DRUJ and proximal radioulnar joint (PRUJ are similar though not identical under axial loading conditions. The purpose of the study was to assess the articulating surface areas of the radioulnar joints and the volumes of the forearm bones addressing the hypothesis that there may be anatomic adaptations that reflect the biomechanical function of the integrated forearm unit.MethodsThe articulating surface areas of PRUJ and DRUJ were assessed using a laser scanner in 24 cadaver forearms. The articulating joint surfaces were additionally delineated from standardized photographs assessed by three observers. The surface areas of matched pairs of joints were compared on the null hypothesis that these were the same within a given forearm specimen. An additional 44 pairs of matched forearm bone volumes were measured using water displacement technique and again compared through statistical analysis (paired sample t-test, and Bland Altman analysis.ResultsThe findings of this study are that the articulating surface areas of the DRUJ and PRUJ as well as the bone volumes are significantly different and yet strongly correlated. The paired sample t-test showed a significant difference between the surface areas of the DRUJ and PRUJ (p<0.05. The PRUJ articulating surface area was marginally larger than the DRUJ with a PRUJ : DRUJ ratio of 1.02. Paired sample t-test showed a significant difference between the two bone volumes (p<0.01 with a radius to ulna bone volume ratio of 0.81. When the olecranon was disregarded, radius volume was on average 4% greater than ulna volume.ConclusionsThis study demonstrated defines the anatomical relationships between the two forearm bones and their articulating joints when matched for specimen. The data

  16. Stress fractures of the femora in soldiers

    International Nuclear Information System (INIS)

    Meurman, K.O.A.; Somer, K.; Lamminen, A.

    1981-01-01

    Amongst 936 stress fractures found in soldiers, there were 58 in the femora (6%); of these 31 were in the neck and 27 in the shaft. Two were bilateral, and two patients had other stress fractures. Three displacements were found in the necks. In the shaft, 20 fractures were proximal, four were in the middle third and three in the distal third. In the latter group, it is necessary to differentiate from a sarcoma. CT is a new aid in this respect. Sport in highly motivated individuals appears to contribute particularly to fractures of the shaft. The symptoms from these fractures are relatively mild. (orig.) [de

  17. Stress fractures of the femora in soldiers

    Energy Technology Data Exchange (ETDEWEB)

    Meurman, K O.A.; Somer, K; Lamminen, A

    1981-05-01

    Amongst 936 stress fractures found in soldiers, there were 58 in the femora (6%); of these 31 were in the neck and 27 in the shaft. Two were bilateral, and two patients had other stress fractures. Three displacements were found in the necks. In the shaft, 20 fractures were proximal, four were in the middle third and three in the distal third. In the latter group, it is necessary to differentiate from a sarcoma. CT is a new aid in this respect. Sport in highly motivated individuals appears to contribute particularly to fractures of the shaft. The symptoms from these fractures are relatively mild.

  18. External jig in the placement of distal interlocking screws | Ikem ...

    African Journals Online (AJOL)

    Retrograde (52.2%) was the commonest surgical approach used for femur. The main indication for SIGN interlocking surgery was recent fracture 77.8%. Open reduction 97.8% was the commonest method of reduction used. The mean±SD bone union time was 3.58±0.56 months and range 3-5 months. Distal screw insertion ...

  19. Treatment of high-energy pilon fractures using the ILIZAROV treatment

    OpenAIRE

    Osman, Walid; Alaya, Zeineb; Kaziz, Hamdi; Hassini, Lassad; Braiki, Meriem; Naouar, Nader; Ben Ayeche, Mohamed Laaziz

    2017-01-01

    The management of high-energy pilon fractures is still controversial. Open reduction and internal fixation are often associated with serious complications. Various methods have been used to treat these injuries, with variable results. The aim of this retrospective study was to analyze the clinical and radiographic outcome of the ILIZAROV technique in patients with high-energy pilon fractures. Thirty cases of distal tibia epiphysis fractures (pilon fractures) were managed from 1999 to 2012. Th...

  20. Sex determination from the radius and ulna in a modern South African sample.

    Science.gov (United States)

    Barrier, I L O; L'Abbé, E N

    2008-07-18

    With a large number of unidentified skeletal remains found in South Africa, the development of population specific osteometric standards is imperative. Forensic anthropologists need to have access to a variety of techniques to establish accurate demographic profiles from complete, fragmentary and/or commingled remains. No research has been done on the forearm of African samples, even though these bones have been shown to exhibit sexual dimorphism. The purpose of this paper is to develop discriminant function formulae to determine sex from the radius and ulna in a South African population. The sample consisted of 200 male and 200 female skeletons from the Pretoria Bone (University of Pretoria) and Raymond A. Dart (Witwatersrand University) collections. Sixteen standard anthropometric measurements were taken from the radius (9) and ulna (7) and subjected to stepwise and direct discriminant function analysis. Distal breadth, minimum mid-shaft diameter and maximum head diameter were the best discriminators of sex for the radius, while minimum mid-shaft diameter and olecranon breadth were selected for the ulna. Classification accuracy for the forearm ranged from 76 to 86%. The radius and ulna can be considered moderate discriminators for determining sex in a South African group. However, it is advised that these formulae are used in conjunction with additional methods to determine sex.

  1. Anterior fracture displacement in Colles’ fractures after Kapandji wiring in women over 59 years

    Science.gov (United States)

    Verdonk, René

    2006-01-01

    The aim of this study was to assess the radiological results of Colles’ fractures treated with Kapandji wiring and to determine the frequency of postoperative anterior fracture displacement. The X-rays of 89 fractures in women over 59 years of age were evaluated. Five weeks after injury, palmar shift of the distal fracture fragments and/or palmar tilt of more than 20° were observed in 26 patients. In ten wrists dorsal tilt was not sufficiently corrected and measured more than 10°. Increase in ulnar variance was more than 2 mm in 37 wrists and more than 5 mm in six wrists; this was more pronounced when the palmar tilt was not corrected properly or when anterior fracture displacement was present. We conclude that Kapandji wiring may not be able to prevent anterior fracture displacement in almost one-third of Colles’ fractures in osteoporotic elderly patients. PMID:16865364

  2. Fracture Risk Assessment in Chronic Kidney Disease, Prospective Testing Under Real World Environments (FRACTURE: a prospective study

    Directory of Open Access Journals (Sweden)

    West Sarah L

    2010-08-01

    Full Text Available Abstract Background Chronic kidney disease (CKD is associated with an increased risk of fracture. Decreased bone mass and disruption of microarchitecture occur early in the course of CKD and worsens with the progressive decline in renal function so that at the time of initiation of dialysis at least 50% of patients have had a fracture. Despite the excess fracture risk, and the associated increases in morbidity and mortality, little is known about the factors that are associated with an increase in fracture risk. Our study aims to identify prognostic factors for bone loss and fractures in patients with stages 3 to 5 CKD. Methods This prospective study aims to enroll two hundred and sixty men and women with stages 3 to 5 CKD. Subjects will be followed for 24 months and we will examine the ability of: 1 bone mineral density by dual x-ray absorptiometry at the spine, hip, and radius; 2 volumetric bone density by high resolution peripheral quantitated computed tomography at the radius and tibia; 3 serum markers of bone turnover; 4 bone formation rate by bone biopsy; and 5 muscle strength and balance to predict spine and non-spine fractures, identified by self-report and/or vertebral morphometry. All measurements will be obtained at baseline, at 12 and at 24 months with the exception of bone biopsy, which will be measured once at 12 months. Subjects will be contacted every 4 months to determine if there have been incident fractures or falls. Discussion This study is one of the first that aims to identify risk factors for fracture in early stage CKD patients. Ultimately, by identifying risk factors for fracture and targeting treatments in this group-before the initiation of renal replacement therapy - we will reduce the burden of disease due to fractures among patients with CKD.

  3. The Changed Route of Anterior Tibial Artery due to Healed Fracture

    Directory of Open Access Journals (Sweden)

    Kemal Gökkuş

    2016-01-01

    Full Text Available We would like to highlight unusual sequelae of healed distal third diaphyseal tibia fracture that was treated conservatively 36 years ago, in which we incidentally detected peripheral CT angiography. The anterior tibial artery was enveloped three-quarterly by the healing callus of the bone (distal tibia.

  4. Theoretical distribution of load in the radius and ulna carpal joint.

    Science.gov (United States)

    Márquez-Florez, Kalenia; Vergara-Amador, Enrique; de Las Casas, Estevam Barbosa; Garzón-Alvarado, Diego A

    2015-05-01

    The purpose of this study is to validate a model for the analysis of the load distribution through the wrist joint, subjected to forces on the axes of the metacarpals from distal to proximal for two different mesh densities. To this end, the Rigid Body Spring Model (RBSM) method was used on a three-dimensional model of the wrist joint, simulating the conditions when making a grip handle. The cartilage and ligaments were simulated as springs acting under compression and tension, respectively, while the bones were considered as rigid bodies. At the proximal end of the ulna the movement was completely restricted, and the radius was allowed to move only in the lateral/medial direction. With these models, we found the load distributions on each carpal articular surface of radius. Additionally, the results show that the percentage of the applied load transmitted through the radius was about 86% for one mesh and 88% for the coarser one; for the ulna it was 21% for one mesh and 18% for the coarser. The obtained results are comparable with previous outcomes reported in prior studies. The latter allows concluding that, in theory, the methodology can be used to describe the changes in load distribution in the wrist. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Development of stress-modified fracture strain criterion for ductile fracture of API X65 steel

    International Nuclear Information System (INIS)

    Oh, Chang Kyun; Kim, Yun Jae; Park, Jin Moo; Kim, Woo Sik; Baek, Jong Hyun

    2005-01-01

    This paper presents a stress-modified fracture strain for API X65 steel used for gas pipeline, as a function of stress triaxiality. To determine the stress-modified fracture strain, tension test of bars with four different notch radii, made of API X65 steel, is firstly performed, from which true fracture strains are determined as a function of notch radius. Then detailed elastic-plastic, large strain Finite Element (FE) analyses are performed to estimate variations of stress triaxiality in the notched bars with load. Combining experimental with FE results provides the true fracture strain as a function of stress triaxiality, which is regarded as a criterion of ductile fracture. Application of the developed stress-modified fracture strain to failure prediction of gas pipes made of API X65 steel with various types of defects is discussed

  6. Indentation deformation and fracture of thin polystyrene films

    International Nuclear Information System (INIS)

    Li Min; Palacio, Manuel L.; Barry Carter, C.; Gerberich, William W.

    2002-01-01

    Nanoindentation-induced deformation and fracture of thin polystyrene (PS) films on glass substrates were characterized using visible-light microscopy and atomic force microscopy (AFM). Two film thicknesses, 2 and 3.5 μm were studied. It was difficult to induce delamination in the 2-μm film while the 3.5-μm film delaminated easily under indentation loads of 150 mN and higher. AFM cross-section analysis of the deformation and fracture geometry revealed that the ratio of the delamination radius to contact radius was between 3 and 4. Analysis of the fracture surface on the glass side indicates that substrate cracking acts as a trigger for initiation and propagation of interfacial cracks. Crack-arrest marks and process-zone marks were also observed by AFM imaging. The interfacial fracture toughness, or practical work of adhesion, was evaluated following two methods based on the indentation-induced delamination and a process-zone analysis. The fracture toughness was found to be approximately 0.6 J/m 2 for the 3.5-μm PS film on glass. AFM examination of the glass surface after indentation also showed fine flow lines around the indentation impression, indicating plastic deformation of glass

  7. Indentation deformation and fracture of thin polystyrene films

    Energy Technology Data Exchange (ETDEWEB)

    Li Min; Palacio, Manuel L.; Barry Carter, C.; Gerberich, William W

    2002-09-02

    Nanoindentation-induced deformation and fracture of thin polystyrene (PS) films on glass substrates were characterized using visible-light microscopy and atomic force microscopy (AFM). Two film thicknesses, 2 and 3.5 {mu}m were studied. It was difficult to induce delamination in the 2-{mu}m film while the 3.5-{mu}m film delaminated easily under indentation loads of 150 mN and higher. AFM cross-section analysis of the deformation and fracture geometry revealed that the ratio of the delamination radius to contact radius was between 3 and 4. Analysis of the fracture surface on the glass side indicates that substrate cracking acts as a trigger for initiation and propagation of interfacial cracks. Crack-arrest marks and process-zone marks were also observed by AFM imaging. The interfacial fracture toughness, or practical work of adhesion, was evaluated following two methods based on the indentation-induced delamination and a process-zone analysis. The fracture toughness was found to be approximately 0.6 J/m{sup 2} for the 3.5-{mu}m PS film on glass. AFM examination of the glass surface after indentation also showed fine flow lines around the indentation impression, indicating plastic deformation of glass.

  8. The Prevalence of Unanticipated Hamate Hook Abnormalities in Computed Tomography Scans: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    Silke A. Spit

    2017-05-01

    Full Text Available Background:It is possible that some hamate hook fractures are not diagnosed or treated, thereby affecting the study of their natural history. Study of the prevalence of incidental hamate hook fractures, nonunions, and other abnormalities on computed tomography (CT ordered for another reason could document a subset of undiagnosed and untreated hamate hook fractures which might change our understanding about the natural history.Methods: Reports of 2489 hand, wrist, and forearm CT scans for hamate hook abnormalities were searched. We excluded 19 patients with anticipated hamate fractures and 1 patient that had a hamate hook excision. Twenty-eight patients had an unanticipated hamate hook abnormality.Results: There was a significant difference in the prevalence of incidental hamate hook abnormalities by sex but not by age. Among the 28 unexpected hamate hook abnormalities, there were 16 fractures of the base (12 acute, 1 nonunion, and 3 of uncertain age, 5 acute oblique fractures, and 7 tip abnormalities/ossicles. The patient with an incidental nonunion had a CT scan for wrist pain and was diagnosed with gout.All fractures involved a direct blow to the hand (distal radius or scaphoid fracture, or crush injury. The 7 patients with a hamate tip abnormality had a CT scan for a distal radius or metacarpal fracture, crush injury or wrist pain. Five acute fractures were treated operatively with excision and the other 23 fractures were treated nonoperatively.Conclusion: Hamate fractures can be diagnosed incidental to other hand and wrist problems on CT.

  9. Resultados clínico-radiológicos en pacientes jóvenes con fractura articular completa de radio distal tratados con placa palmar bloqueada. [Clinical and radiological results in young patients with complete articular distal radius fractures treated with volar locked plate.

    Directory of Open Access Journals (Sweden)

    Pablo De Carli

    2016-02-01

    Conclusión: El tratamiento de las fracturas de radio distal tipo C en pacientes jóvenes con placa palmar bloqueada muestra resultados clínicos y radiológicos favorables con corrección de la mayoría de los escalones articulares.

  10. The strength of polyaxial locking interfaces of distal radius plates.

    Science.gov (United States)

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2009-10-01

    Currently available polyaxial locking plates represent the consequent enhancement of fixed-angle, first-generation locking plates. In contrast to fixed-angle locking plates which are sufficiently investigated, the strength of the new polyaxial locking options has not yet been evaluated biomechanically. This study investigates the mechanical strength of single polyaxial interfaces of different volar radius plates. Single screw-plate interfaces of the implants Palmar 2.7 (Königsee Implantate und Instrumente zur Osteosynthese GmbH, Allendorf, Germany), VariAx (Stryker Leibinger GmbH & Co. KG, Freiburg, Germany) und Viper (Integra LifeSciences Corporation, Plainsboro, NJ, USA) were tested by cantilever bending. The strength of 0 degrees, 10 degrees and 20 degrees screw locking angle was obtained during static and dynamic loading. The Palmar 2.7 interfaces showed greater ultimate strength and fatigue strength than the interfaces of the other implants. The strength of the VariAx interfaces was about 60% of Palmar 2.7 in both, static and dynamic loading. No dynamic testing was applied to the Viper plate because of its low ultimate strength. By static loading, an increase in screw locking angle caused a reduction of strength for the Palmar 2.7 and Viper locking interfaces. No influence was observed for the VariAx locking interfaces. During dynamic loading; angulation had no influence on the locking strength of Palmar 2.7. However, reduction of locking strength with increasing screw angulation was observed for VariAx. The strength of the polyaxial locking interfaces differs remarkably between the examined implants. Depending on the implant an increase of the screw locking angle causes a reduction of ultimate or fatigue strength, but not in all cases a significant impact was observed.

  11. [The Postero-Lateral Approach--An Alternative to Closed Anterior-Posterior Screw Fixation of a Dislocated Postero-Lateral Fragment of the Distal Tibia in Complex Ankle Fractures].

    Science.gov (United States)

    von Rüden, C; Hackl, S; Woltmann, A; Friederichs, J; Bühren, V; Hierholzer, C

    2015-06-01

    The dislocated posterolateral fragment of the distal tibia is considered as a key fragment for the successful reduction of comminuted ankle fractures. The reduction of this fragment can either be achieved indirectly by joint reduction using the technique of closed anterior-posterior screw fixation, or directly using the open posterolateral approach followed by plate fixation. The aim of this study was to compare the outcome after stabilization of the dislocated posterolateral tibia fragment using either closed reduction and screw fixation, or open reduction and plate fixation via the posterolateral approach in complex ankle fractures. In a prospective study between 01/2010 and 12/2012, all mono-injured patients with closed ankle fractures and dislocated posterolateral tibia fragments were assessed 12 months after osteosynthesis. Parameters included: size of the posterolateral tibia fragment relative to the tibial joint surface (CT scan, in %) as an indicator of injury severity, unreduced area of tibial joint surface postoperatively, treatment outcome assessed by using the "Ankle Fracture Scoring System" (AFSS), as well as epidemiological data and duration of the initial hospital treatment. In 11 patients (10 female, 1 male; age 51.6 ± 2.6 years [mean ± SEM], size of tibia fragment 42.1 ± 2.5 %) the fragment fixation was performed using a posterolateral approach. Impaired postoperative wound healing occurred in 2 patients of this group. In the comparison group, 12 patients were treated using the technique of closed anterior-posterior screw fixation (10 female, 2 male; age 59.5 ± 6.7 years, size of tibia fragment 45.9 ± 1.5 %). One patient of this group suffered an incomplete lesion of the superficial peroneal nerve. Radiological evaluation of the joint surface using CT scan imaging demonstrated significantly less dislocation of the tibial joint surface following the open posterolateral approach (0.60 ± 0.20 mm) compared to the closed

  12. Dynamic osteosynthesis by modified Kuntscher nail for the treatment of tibial diaphyseal fractures.

    Science.gov (United States)

    Gadegone, Wasudeo M; Salphale, Yogesh S

    2009-04-01

    We evaluated a series of diaphyseal fractures of the tibia using low-cost, Indian-made modified Kuntscher nail (Daga nail) with the provision of distal locking screw for the management of the tibial diaphyseal fractures. One hundred and fifty one consecutive patients with diaphyseal fractures of tibia with 151 fractures who were treated by Daga nail were enrolled. One of the patients who had died because of cancer, and the two patients who were lost to follow-up at 3 months were excluded from the study.Therefore data of 148 patients with one hundred and fortyeight fractures is described. One hundred twenty closed fractures, 20 open Grade I fractures, and eight open Grade II fractures as per Gustilo and Anderson classification were included in this study. One hundred fourteen men and 34 women, with a mean age of 38.4 years, were studied. The result were analysed for Surgical time, duration of hospitalisation, union time, union rate, complication rate, functional recovery and crutch walking time. The fractures were followed at least until the time of solid union. The follow-up period averaged 15 months (range, 6-26 months). Union occurred in 140 cases (94.6%). The mean time to union was 13 weeks for closed fractures,17.8 weeks for Grade I open fractures, and 21.6 weeks for Grade II open fractures. Compartment syndrome occurred in two patients. Superficial infection occurred in five cases of Grade I and II compound fractures. Three closed fractures and one case of Grade I compound fracture required bone grafting for delayed union. Two cases of Grade II compound fracture with nonunion required revision surgery and bone grafting. Twelve cases resulted in acceptable malalignment due to operative technical error. In four cases, the distal screw breakage was seen, but none of these complications interfered with fracture healing. Recovery of joint motion was essentially normal in those patients without knee or ankle injury. Unreamed distally locked dynamic tibial nailing

  13. Dynamic osteosynthesis by modified Kuntscher nail for the treatment of tibial diaphyseal fractures

    Directory of Open Access Journals (Sweden)

    Gadegone Wasudeo

    2009-01-01

    Full Text Available Background: We evaluated a series of diaphyseal fractures of the tibia using low-cost, Indian-made modified Kuntscher nail (Daga nail with the provision of distal locking screw for the management of the tibial diaphyseal fractures. Materials and Methods: One hundred and fifty one consecutive patients with diaphyseal fractures of tibia with 151 fractures who were treated by Daga nail were enrolled. One of the patients who had died because of cancer, and the two patients who were lost to follow-up at 3 months were excluded from the study.Therefore data of 148 patients with one hundred and fortyeight fractures is described. One hundred twenty closed fractures, 20 open Grade I fractures, and eight open Grade II fractures as per Gustilo and Anderson classification were included in this study. One hundred fourteen men and 34 women, with a mean age of 38.4 years, were studied. The result were analysed for Surgical time, duration of hospitalisation, union time, union rate, complication rate, functional recovery and crutch walking time. The fractures were followed at least until the time of solid union. Results: The follow-up period averaged 15 months (range, 6-26 months. Union occurred in 140 cases (94.6%. The mean time to union was 13 weeks for closed fractures,17.8 weeks for Grade I open fractures, and 21.6 weeks for Grade II open fractures. Compartment syndrome occurred in two patients. Superficial infection occurred in five cases of Grade I and II compound fractures. Three closed fractures and one case of Grade I compound fracture required bone grafting for delayed union. Two cases of Grade II compound fracture with nonunion required revision surgery and bone grafting. Twelve cases resulted in acceptable malalignment due to operative technical error. In four cases, the distal screw breakage was seen, but none of these complications interfered with fracture healing. Recovery of joint motion was essentially normal in those patients without knee or

  14. Prevalence of osteoporosis and incidence of hip fracture in women - secular trends over 30 years

    Directory of Open Access Journals (Sweden)

    Sernbo Ingemar

    2010-03-01

    Full Text Available Abstract Background The number of hip fractures during recent decades has been reported to be increasing, partly because of an increasing proportion of elderly women in the society. However, whether changes in hip fracture annual incidence in women are attributable to secular changes in the prevalence of osteoporosis is unclear. Methods Bone mineral density was evaluated by single-photon absorptiometry at the distal radius in 456 women aged 50 years or above and living in the same city. The measurements were obtained by the same densitometer during three separate time periods: 1970-74 (n = 106, 1987-93 (n = 175 and 1998-1999 (n = 178, and the age-adjusted prevalence of osteoporosis in these three cohorts was calculated. Additionally, all hip fractures sustained in the target population of women aged 50 years or above between 1967 and 2001 were registered, whereupon the crude and the age-adjusted annual incidence of hip fractures were calculated. Results There was no significant difference in the age-adjusted prevalence of osteoporosis when the three cohorts were compared (P = 1.00. The crude annual incidence (per 10,000 women of hip fracture in the target population increased by 110% from 40 in 1967 to 84 in 2001. The overall trend in the crude incidence between 1967 and 2001 was increasing (1.58 per 10,000 women per year; 95 percent confidence interval, 1.17 to 1.99, whereas the age-adjusted incidence was stable over the same period (0.22 per 10,000 women per year; 95 percent confidence interval, -0.16 to 0.60. Conclusions The increased number of hip fracture in elderly women is more likely to be attributable to demographic changes in the population than to secular increase in the prevalence of osteoporosis.

  15. The management of acute distal tibio-fibular syndesmotic injuries: Results of a nationwide survey

    NARCIS (Netherlands)

    Schepers, Tim; van Zuuren, Wouter J.; van den Bekerom, Michel P. J.; Vogels, Lucas M. M.; van Lieshout, Esther M. M.

    2012-01-01

    Ankle fractures are one of the most frequently encountered musculoskeletal injuries, and 10% of patients have a concomitant distal tibiofibular syndesmotic disruption necessitating surgical repair. A national survey was conducted to gain more insight into the current approaches in the management of

  16. [Anatomy of fractures of the inferior scapular angle].

    Science.gov (United States)

    Bartoníček, J; Tuček, M; Malík, J

    2018-01-01

    The aim of this study is to describe the anatomy of fractures of the inferior angle and the adjacent part of the scapular body, based on 3D CT reconstructions. In a series of 375 scapular fractures, we identified a total of 20 fractures of the inferior angle of the scapular body (13 men, 7 women), with a mean patient age of 50 years (range 3373). In all fractures, 3D CT reconstructions were obtained, allowing an objective evaluation of the fracture pattern with a focus on the size and shape of the inferior angle fragment, propagation of the fracture line to the lateral and medial borders of the infraspinous part of the scapular body, fragment displacement and any additional fracture of the ipsilateral scapula and the shoulder girdle. We identified a total of 5 types of fracture involving the distal half of the infraspinous part of the scapular body. The first type, recorded in 5 cases, affected only the apex of the inferior angle, with a small part of the adjacent medial border. The second type, occurring in 4 cases, involved fractures separating the entire inferior angle. The third type, represented by 4 cases, was characterized by a fracture line starting medially close above the inferior angle and passing proximolaterally. The separated fragment had a shape of a big drop, carrying also the distal half of the lateral pillar in addition to the inferior angle. In the fourth type identified in 5 fractures, the separated fragment was formed both by the inferior angle and a variable part of the medial border. The fifth type, being by its nature a transition to the fracture of the infraspinous part of the body, was recorded in 2 cases, with the same V-shaped fragment. Fractures of the inferior angle and the adjacent part of the scapular body are groups of fractures differing from other infraspinous fractures of the scapular body. Although these fractures are highly variable in terms of shape, they have the same course of fracture line and the manner of displacement

  17. Fracture Mechanics Assessment for Different Notch Sizes Using Finite Element Analysis Based on Ductile Failure Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Keun Hyung; Jeon, Jun Young; Han, Jae Jun; Nam, Hyun Suk; Lee, Dae Young; Kim, Yun Jae [Korea Univ., Seoul (Korea, Republic of)

    2016-08-15

    In this study, notch defects are evaluated using fracture mechanics. To understand the effects of notch defects, FE analysis is conducted to predict the limit load and J-integral for middle-cracked and single-edge cracked plates with various sizes of notch under tension and bending. As the radius of the notch increases, the energy release rate also increases, although the limit load remains constant. The values of fracture toughness(J{sub IC}) of SM490A are determined for various notch radii through FE simulation instead of conducting an experiment. As the radius of the notch increases, the energy release rate also increases, together with a more significant increase in fracture toughness. To conclude, as the notch radius increases, the resistance to crack propagation also increases.

  18. Non union of an epiphyseal fibular fracture in a pediatric patient.

    Science.gov (United States)

    Mirmiran, Roya; Schuberth, John M

    2006-01-01

    There are few reports on delayed or nonunion in the pediatric ankle fracture. The authors present a case of a nonunion of a mid-epiphyseal fracture of the distal fibula, described as a type 7 pediatric fracture. Both the occurrence of this injury pattern and a nonunion has not been reported in the same patient. Operative reduction of the nonunion resulted in a satisfactory outcome.

  19. SURGICAL TREATMENT OF MALUNITED COLLES’ FRACTURE BY CORRECTIVE OSTEOTOMY

    Directory of Open Access Journals (Sweden)

    Gopinath

    2015-12-01

    Full Text Available BACKGROUND Malunion occurs more often after Colles fracture than any other and can result in considerable disability. Multiple techniques for corrective osteotomy have been developed in recent years with objective of restoring the normal anatomy of distal end of radius and also to evaluate the results with respect to pain, restoration of function of wrist and forearm. MATERIALS AND METHODS A prospective randomized controlled study was conducted in 20 cases of malunited Colles fracture who underwent Corrective osteotomy with a Dorsal Ellis T plate and bone graft. Post operatively all patients were immobilized on a Sugar-Tong splint and followed up at 4, 6 and 12 weeks. RESULTS All measurements of Pain, final range of motion and grip strength significantly improved compared with preoperative measurements. Based on Fernandez et al scoring system we obtained Excellent results in 8 cases, Good in 7 cases, Fair in 3 cases and Poor in 2 cases which was attributed to infection in 1 case and RSD in the other case. Radiologically a mean radial length of 6.14mm (N:10mm, Radial Angle of 21.25⁰ (N:22⁰ and Volar angle of -3.4⁰ (N: +4⁰ was achieved. CONCLUSION Corrective Osteotomy with Bone graft is a preferred and an Ideal procedure if performed after Proper selection of patients i.e in young adults and extra articular malunions with good range of movements.

  20. DISTAL MYOPATHIES

    Science.gov (United States)

    Dimachkie, Mazen M.; Barohn, Richard J.

    2014-01-01

    Over a century ago, Gowers described two young patients in whom distal muscles weakness involved the hand, foot, sternocleidomastoid, and facial muscles in the other case the shoulder and distal leg musculature. Soon after, , similar distal myopathy cases were reported whereby the absence of sensory symptoms and of pathologic changes in the peripheral nerves and spinal cord at postmortem examination allowed differentiation from Charcot-Marie-Tooth disease. In 1951, Welander described autosomal dominant (AD) distal arm myopathy in a large Scandanavian cohort. Since then the number of well-characterized distal myopathies has continued to grow such that the distal myopathies have formed a clinically and genetically heterogeneous group of disorders. Affected kindred commonly manifest weakness that is limited to foot and toe muscles even in advanced stages of the disease, with variable mild proximal leg, distal arm, neck and laryngeal muscle involvement in selected individuals. An interesting consequence of the molecular characterization of the distal myopathies has been the recognition that mutation in a single gene can lead to more than one clinical disorder. For example, Myoshi myopathy (MM) and limb girdle muscular dystrophy (LGMD) type 2B are allelic disorders due to defects in the gene that encodes dysferlin. The six well described distal myopathy syndromes are shown in Table 1. Table 2 lists advances in our understanding of the myofibrillar myopathy group and Table 3 includes more recently delineated and less common distal myopathies. In the same manner, the first section of this review pertains to the more traditional six distal myopathies followed by discussion of the myofibrillar myopathies. In the third section, we review other clinically and genetically distinctive distal myopathy syndromes usually based upon single or smaller family cohorts. The fourth section considers other neuromuscular disorders that are important to recognize as they display prominent

  1. Filling Open Screw Holes in the Area of Metaphyseal Comminution Does Not Affect Fatigue Life of the Synthes Variable Angle Distal Femoral Locking Plate in the AO/OTA 33-A3 Fracture Model.

    Science.gov (United States)

    Grau, Luis; Collon, Kevin; Alhandi, Ali; Kaimrajh, David; Varon, Maria; Latta, Loren; Vilella, Fernando

    2018-06-01

    The aim of this study is to evaluate the biomechanical effect of filling locking variable angle (VA) screw holes at the area of metaphyseal fracture comminution in a Sawbones® (Sawbones USA, Vashon, Washington) model (AO/OTA 33A-3 fracture) using a Synthes VA locking compression plate (LCP) (Depuy Synthes, Warsaw, Indiana). Seven Sawbones® femur models had a Synthes VA-LCP placed as indicated by the manufacturers technique. A 4cm osteotomy was then created to simulate an AO/OTA 33-A3 femoral fracture pattern with metaphyseal comminution. The control group consisted of four constructs in which the open screw holes at the area of comminution were left unfilled; the experimental group consisted of three constructs in which the VA screw holes were filled with locking screws. One of the control constructs was statically loaded to failure at a rate of 5mm/min. A value equal to 75% of the ultimate load to failure was used as the loading force for fatigue testing of 250,000 cycles at 3Hz. Cycles to failure was recorded for each construct and averages were compared between groups. The average number of cycles to failure in the control and experimental groups were 37524±8187 and 43304±23835, respectively (p=0.72). No significant difference was observed with respect to cycles to failure or mechanism of failure between groups. In all constructs in both the control and experimental groups, plate failure reproducibly occurred with cracks through the variable angle holes in the area of bridged comminution. The Synthes VA-LCP in a simulated AO/OTA 33-A3 comminuted metaphyseal femoral fracture fails in a reproducible manner at the area of comminution through the "honeycomb" VA screw holes. Filling open VA screw holes at the site of comminution with locking screws does not increase fatigue life of the Synthes VA-LCP in a simulated AO/OTA 33-A3 distal femoral fracture. Further studies are necessary to determine whether use of this particular plate is contraindicated when bridging

  2. An unusual stress fracture: Bilateral posterior longitudinal stress fracture of tibia.

    Science.gov (United States)

    Malkoc, Melih; Korkmaz, Ozgur; Ormeci, Tugrul; Oltulu, Ismail; Isyar, Mehmet; Mahirogulları, Mahir

    2014-01-01

    Stress fractures (SF) occur when healthy bone is subjected to cyclic loading, which the normal carrying range capacity is exceeded. Usually, stress fractures occur at the metatarsal bones, calcaneus, proximal or distal tibia and tends to be unilateral. This article presents a 58-year-old male patient with bilateral posterior longitudinal tibial stress fractures. A 58 years old male suffering for persistent left calf pain and decreased walking distance for last one month and after imaging studies posterior longitudinal tibial stress fracture was detected on his left tibia. After six months the patient was admitted to our clinic with the same type of complaints in his right leg. All imaging modalities and blood counts were performed and as a result longitudinal posterior tibial stress fractures were detected on his right tibia. Treatment of tibial stress fracture includes rest and modified activity, followed by a graded return to activity commensurate with bony healing. We have applied the same treatment protocol and our results were acceptable but our follow up time short for this reason our study is restricted for separate stress fractures of the posterior tibia. Although the main localization of tibial stress fractures were unilateral, anterior and transverse pattern, rarely, like in our case, the unusual bilateral posterior localization and longitudinal pattern can be seen. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Falling Down on the Job: Evaluation and Treatment of Fall Risk Among Older Adults With Upper Extremity Fragility Fractures.

    Science.gov (United States)

    McDonough, Christine M; Colla, Carrie H; Carmichael, Donald; Tosteson, Anna N A; Tosteson, Tor D; Bell, John-Erik; Cantu, Robert V; Lurie, Jonathan D; Bynum, Julie P W

    2017-03-01

    Clinical practice guidelines recommend fall risk assessment and intervention for older adults who sustain a fall-related injury to prevent future injury and mobility decline. The aim of this study was to describe how often Medicare beneficiaries with upper extremity fracture receive evaluation and treatment for fall risk. Observational cohort. Participants were fee-for-service beneficiaries age 66 to 99 treated as outpatients for proximal humerus or distal radius/ulna ("wrist") fragility fractures. -Participants were studied using Carrier and Outpatient Hospital files. The proportion of patients evaluated or treated for fall risk up to 6 months after proximal humerus or wrist fracture from 2007-2009 was examined based on evaluation, treatment, and diagnosis codes. Time to evaluation and number of treatment sessions were calculated. Logistic regression was used to analyze patient characteristics that predicted receiving evaluation or treatment. Narrow (gait training) and broad (gait training or therapeutic exercise) definitions of service were used. There were 309,947 beneficiaries who sustained proximal humerus (32%) or wrist fracture (68%); 10.7% received evaluation or treatment for fall risk or gait issues (humerus: 14.2%; wrist: 9.0%). Using the broader definition, the percentage increased to 18.5% (humerus: 23.4%; wrist: 16.3%). Factors associated with higher likelihood of services after fracture were: evaluation or treatment for falls or gait prior to fracture, more comorbidities, prior nursing home stay, older age, humerus fracture (vs wrist), female sex, and white race. Claims analysis may underestimate physician and physical therapist fall assessments, but it is not likely to qualitatively change the results. A small proportion of older adults with upper extremity fracture received fall risk assessment and treatment. Providers and health systems must advance efforts to provide timely evidence-based management of fall risk in this population. © 2017

  4. Hoverboards: spectrum of injury and association with an uncommon fracture

    International Nuclear Information System (INIS)

    Schapiro, Andrew H.; Lall, Neil U.; Anton, Christopher G.; Trout, Andrew T.

    2017-01-01

    Self-balancing electric scooters, commonly known as hoverboards, are a new and popular consumer item with recognized fall hazards. The spectrum of injuries associated with hoverboard use has not been studied. The purpose of this study is to determine the spectrum of radiologically apparent injuries associated with hoverboard use. We retrospectively reviewed all imaging studies interpreted at our institution for hoverboard-related injuries during an 8-month period. We recorded patient demographics and injury characteristics. Thirty-two of the 47 pediatric patients imaged for hoverboard-related injury had radiologically detectable injuries, all fractures. Fifty percent of these 32 patients were female and 50% were male, with a mean age of 12.4 years. There were 42 fractures total, all involving the appendicular skeleton, with 74% in the upper extremities and 26% in the lower extremities. Thirty-eight percent of the fractures involved the physis. A distinct injury pattern was seen in three patients who sustained open distal phalanx juxta-epiphyseal fractures. Most of the fractures sustained during hoverboard use are commonly seen in everyday pediatric radiology practice, with an overall pattern paralleling that reported in association with skateboard use. However an otherwise uncommon fracture, the distal phalanx juxta-epiphyseal fracture, was identified in association with hoverboard use, and this finding has important treatment implications including need for irrigation and debridement, antibiotic therapy, and potential surgical fixation. (orig.)

  5. Hoverboards: spectrum of injury and association with an uncommon fracture

    Energy Technology Data Exchange (ETDEWEB)

    Schapiro, Andrew H.; Lall, Neil U.; Anton, Christopher G.; Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology and Medical Imaging, Cincinnati, OH (United States)

    2017-04-15

    Self-balancing electric scooters, commonly known as hoverboards, are a new and popular consumer item with recognized fall hazards. The spectrum of injuries associated with hoverboard use has not been studied. The purpose of this study is to determine the spectrum of radiologically apparent injuries associated with hoverboard use. We retrospectively reviewed all imaging studies interpreted at our institution for hoverboard-related injuries during an 8-month period. We recorded patient demographics and injury characteristics. Thirty-two of the 47 pediatric patients imaged for hoverboard-related injury had radiologically detectable injuries, all fractures. Fifty percent of these 32 patients were female and 50% were male, with a mean age of 12.4 years. There were 42 fractures total, all involving the appendicular skeleton, with 74% in the upper extremities and 26% in the lower extremities. Thirty-eight percent of the fractures involved the physis. A distinct injury pattern was seen in three patients who sustained open distal phalanx juxta-epiphyseal fractures. Most of the fractures sustained during hoverboard use are commonly seen in everyday pediatric radiology practice, with an overall pattern paralleling that reported in association with skateboard use. However an otherwise uncommon fracture, the distal phalanx juxta-epiphyseal fracture, was identified in association with hoverboard use, and this finding has important treatment implications including need for irrigation and debridement, antibiotic therapy, and potential surgical fixation. (orig.)

  6. Pathology of the distal condyles of the third metacarpal and third metatarsal bones of the horse

    International Nuclear Information System (INIS)

    Riggs, C.M.; Whitehouse, G.H.; Boyde, A.

    1999-01-01

    This study examined material from Thoroughbred horses, the majority of which had been in race training, for evidence of pathology in the third metacarpal (McIII) and third metatarsal (MtIII) bones which might be related to the occurrence of distal condylar fractures. Whole bone samples were studied and documented by macrophotography prior to macroradiography and computed tomographic (CT) imaging. Microradiographs were made from 100 microm thick mediolateral sections cut perpendicular to the dorsal and palmar/plantar articular surfaces of distal condylar regions of McIII and MtIII. Blocks were prepared for morphological imaging using the backscattered electron mode of scanning electron microscopy (BSE SEM). Linear defects in mineralised articular cartilage and subchondral bone were found in the palmar/plantar aspects of the condylar grooves adjacent to the sagittal ridge. These were closely related to the pattern of densification of the subchondral bone and were associated with intense focal remodelling of the immediately adjacent and subjacent bone. Parasagittal fractures of the condyles originated in similar defects. A unifying hypothesis for the aetiopathogenesis of these fractures is presented

  7. Change in fracture risk and fracture pattern after bariatric surgery: nested case-control study.

    Science.gov (United States)

    Rousseau, Catherine; Jean, Sonia; Gamache, Philippe; Lebel, Stéfane; Mac-Way, Fabrice; Biertho, Laurent; Michou, Laëtitia; Gagnon, Claudia

    2016-07-27

     To investigate whether bariatric surgery increases the risk of fracture.  Retrospective nested case-control study.  Patients who underwent bariatric surgery in the province of Quebec, Canada, between 2001 and 2014, selected using healthcare administrative databases.  12 676 patients who underwent bariatric surgery, age and sex matched with 38 028 obese and 126 760 non-obese controls.  Incidence and sites of fracture in patients who had undergone bariatric surgery compared with obese and non-obese controls. Fracture risk was also compared before and after surgery (index date) within each group and by type of surgery from 2006 to 2014. Multivariate conditional Poisson regression models were adjusted for fracture history, number of comorbidities, sociomaterial deprivation, and area of residence.  Before surgery, patients undergoing bariatric surgery (9169 (72.3%) women; mean age 42 (SD 11) years) were more likely to fracture (1326; 10.5%) than were obese (3065; 8.1%) or non-obese (8329; 6.6%) controls. A mean of 4.4 years after surgery, bariatric patients were more susceptible to fracture (514; 4.1%) than were obese (1013; 2.7%) and non-obese (3008; 2.4%) controls. Postoperative adjusted fracture risk was higher in the bariatric group than in the obese (relative risk 1.38, 95% confidence interval 1.23 to 1.55) and non-obese (1.44, 1.29 to 1.59) groups. Before surgery, the risk of distal lower limb fracture was higher, upper limb fracture risk was lower, and risk of clinical spine, hip, femur, or pelvic fractures was similar in the bariatric and obese groups compared with the non-obese group. After surgery, risk of distal lower limb fracture decreased (relative risk 0.66, 0.56 to 0.78), whereas risk of upper limb (1.64, 1.40 to 1.93), clinical spine (1.78, 1.08 to 2.93), pelvic, hip, or femur (2.52, 1.78 to 3.59) fractures increased. The increase in risk of fracture reached significance only for biliopancreatic diversion.  Patients undergoing bariatric

  8. Treatment of type III middle phalangeal neck fractures through a palmar approach: a case report

    Directory of Open Access Journals (Sweden)

    Lucchina Stefano

    2013-04-01

    Full Text Available 【Abstract】 Phalangeal neck fractures occur almost exclusively in children. We present the case of a 49 years old man with a dislocated fracture of the neck of the middle phalanx with the distal fragment rotated at 180°, due to a traumatic circular saw injury to the left index, which was solved by anatomical reduction and bone fixation with two 1.5 mm Synthes screws and a temporary transarticular K-wire at the distal interphalangeal joint. Zone I flexor digitorum profundus repair was performed using a modification of the Kessler 4-strands core suture and a full-thickness skin graft from the hypothenar eminence was taken to cover the skin gap. At 6-month follow-up the patient was pain-free and with a total active movement equivalent to 190°. No radio-logical signs of avascular necrosis of the head of the middle phalanx or nonunion of the distal fragment was detectable with recovery to the previous manual work. Owing to the position of the phalangeal head maintained in position by the collateral ligaments an anatomic reduction from dorsal approach is difficult to be performed and a longitudinal trac-tion can render the reduction harder too. The volar approach permits an easier reduction of the fracture through a derotation of the distal fragment facing palmar. Key words: Finger phalanges; Fractures, bone; Finger joint

  9. Avulsion Fracture of the Coracoid Process at the Coracoclavicular Ligament Insertion: A Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Takeshi Morioka

    2016-01-01

    Full Text Available Avulsion fracture at the site of attachment of the coracoid process of the coracoclavicular ligament (CCL is extremely rare. We presented three adult cases of this unusual avulsion fracture associated with other injuries. Case  1 was a 25-year-old right-handed male with a left distal clavicular fracture with an avulsion fracture of the coracoid attachment of the CCL; this case was treated surgically and achieved an excellent outcome. Case  2 was a 39-year-old right-handed male with dislocation of the left acromioclavicular joint with two avulsion fractures: one at the posteromedial surface of the coracoid process at the attachment of the conoid ligament and one at the inferior surface of the clavicle at the attachment site of the trapezoid ligament; this case was treated conservatively, and unfavorable symptoms such as dull pain at rest and sharp pain during some daily activities remained. Case  3 was a 41-year-old right-handed female with a right distal clavicular fracture with an avulsion fracture of the coracoid attachment of the conoid ligament; this case was treated conservatively, and the distal clavicular fracture became typical nonunion. These three cases corresponded to type I fractures according to Ogawa’s classification as the firm scapuloclavicular connection was destroyed and also to double disruption of the superior shoulder suspensory complex. We recommend surgical intervention when treating patients with this type of acute or subacute injury, especially in those engaging in heavy lifting or overhead work.

  10. Fracture toughness evaluation of small notched specimen in consideration of notch effect and loading rate

    International Nuclear Information System (INIS)

    Lee, Baik Woo; Kwon, Dong Il; Jang, Jae Il

    2000-01-01

    Notch effect and loading rate dependency on fracture toughness were considered when evaluating fracture toughness of small notched specimens using the instrumented impact test. Notch effect was analyzed into stress redistribution effect and stress relaxation with a viewpoint of stress triaxiality. Stress redistribution effect was corrected by introducing effective crack length, which was the sum of actual crack length and plastic zone size. Stress relaxation effect was also corrected using elastic stress concentration factor, which would decrease if plastic deformation occurred. As a result, corrected fracture toughness of the notched specimen was very consistent with the reference fracture toughness obtained using precracked specimen. In addition, limiting notch root radius, below which fracture toughness was independent of notch radius, was observed and discussed. Loading rate dependency on fracture toughness, which was obtained from the static three point bending test and the instrumented impact test, was also discussed with stress field in plastic zone ahead of a notch and fracture based on stress control mechanism. (author)

  11. Simulation of complex fracture networks influenced by natural fractures in shale gas reservoir

    Directory of Open Access Journals (Sweden)

    Zhao Jinzhou

    2014-10-01

    Full Text Available When hydraulic fractures intersect with natural fractures, the geometry and complexity of a fracture network are determined by the initiation and propagation pattern which is affected by a number of factors. Based on the fracture mechanics, the criterion for initiation and propagation of a fracture was introduced to analyze the tendency of a propagating angle and factors affecting propagating pressure. On this basis, a mathematic model with a complex fracture network was established to investigate how the fracture network form changes with different parameters, including rock mechanics, in-situ stress distribution, fracture properties, and frac treatment parameters. The solving process of this model was accelerated by classifying the calculation nodes on the extending direction of the fracture by equal pressure gradients, and solving the geometrical parameters prior to the iteration fitting flow distribution. With the initiation and propagation criterion as the bases for the propagation of branch fractures, this method decreased the iteration times through eliminating the fitting of the fracture length in conventional 3D fracture simulation. The simulation results indicated that the formation with abundant natural fractures and smaller in-situ stress difference is sufficient conditions for fracture network development. If the pressure in the hydraulic fractures can be kept at a high level by temporary sealing or diversion, the branch fractures will propagate further with minor curvature radius, thus enlarging the reservoir stimulation area. The simulated shape of fracture network can be well matched with the field microseismic mapping in data point range and distribution density, validating the accuracy of this model.

  12. Distal tibiofibular synostosis after ankle fracture. A 14-year follow-up study

    NARCIS (Netherlands)

    Albers, G. H.; de Kort, A. F.; Middendorf, P. R.; van Dijk, C. N.

    1996-01-01

    Over an eight-year period up to 1983, a total of 322 consecutive patients had operations for ankle fractures; 176 were Weber type B and 128 type C. We were able to review 230 of these patients after a mean follow-up of six years (1 to 11) including 128 with Weber B and 102 with Weber C fractures. We

  13. COMPARATIVE ANALYSIS OF TREATMENT OUTCOMES IN PATIENTS WITH TYPES B AND C PYLON FRACTURES

    Directory of Open Access Journals (Sweden)

    V. V. Khominets

    2017-01-01

    Full Text Available Objective — to develop and implement improved approaches to the diagnosis and tactics of surgical treatment in patients with fractures of the distal tibia metaepiphysis.Material and methods. The study included 126 patients with fractures of distal tibia metaepiphysis of «B» and «C» types who underwent internal fixation with plates in 2005–2012. The authors analyzed surgical treatment outcomes within the period from 2.5 to 9 years (average of 5.7–2.3 years of postoperative follow up. Average age of patients was 23.4±2.1 years. Patients were divided into the main group (64 patients and the comparison group (62 patients. In the comparison group, traditional approaches to diagnosis and surgical treatment were used, including standard clinical examination and X-rays of the affected ankle in two views and the median access to the distal tibia metaepiphysis. In the main group, a specially elaborated algorithm for selection of optimal surgical tactics was utilized basing on the improved diagnostics program. Clinical and functional data were assessed by Foot and Ankle Outcome Score (FAOS and SF-36 Health Survey. Roentgenological assessment was done by X-rays and CT scans. Statistical significance of the differences was evaluated by Wald-Wolfowitz and Fisher tests.Results. Improved approaches to the tactics of surgical treatment in patients with pylon fractures of «B» and «C» types allowed to reduce the incidence of unsatisfactory anatomical and functional outcomes from 43.5% to 28.1%. The number of satisfactory and good outcomes increased by 4.7% and 10.7% respectively after application of improved therapeutic and diagnostic approaches.Conclusion. Proposed improved approaches to verification of severe intraarticular fractures of the distal tibia metabiphysis allowed to increase the informative value of the diagnostic procedures and to avoid discrepancies between preand intraoperative assessment of fracture type by classifications of M

  14. Post-traumatic cyst-like lesion in children: case report and the literature review.

    Science.gov (United States)

    Angelliaume, Audrey; Simon, Anne-Laure; Tanase, Anca; Mazda, Keyvan; Ilharreborde, Brice

    2016-03-01

    Reports of post-traumatic cyst-like lesions in children are rare. These lesions occur between 1.5 and 3 months after a fracture. They are more frequent after a distal radius greenstick fracture. Conventional radiographs show a metaphyseal radiolucent lesion inside the most recent subperiosteal bone, adjacent to the initial fracture line. Post-traumatic cyst-like lesions are benign, asymptomatic, nonexpansive, and regress spontaneously. Two typical cases are described in the following report with a literature review of the etiology and main features of these lesions.

  15. Finite element analysis of a novel pin-sleeve system for external fixation of distal limb fractures in horses.

    Science.gov (United States)

    Brianza, Stefano; Brighenti, Vittoria; Lansdowne, Jennifer L; Schwieger, Karsten; Bouré, Ludovic

    2011-11-01

    The transfixation pin cast (TPC) is an external skeletal fixation technique used to treat horses with distal limb fractures, but its use is often associated with pin-loosening and an increased risk of treatment failure. To address implant loosening, the pin sleeve cast system (PSC) was recently designed and consists of a pin-sleeve unit inserted into the bone. Each pin runs through a sleeve placed in the bone, making contact at two fixed points only within the sleeve. Each pin is attached to a ring embedded in a resin cast. In this report, the mechanical performance of a traditional TPC pin arrangement was compared with that of the PSC using validated finite element models of bone substitutes previously tested in vitro. The PSC resulted in a marked reduction in peak strain magnitude around the pins and a more even distribution of strain across the bone cortex. The two systems resulted in comparable proximal fragment displacement and had a similar stress concentration around bone defects during implant removal. The findings suggest that the PSC load transfer mechanism is effective even in geometrically complex structures like equine bones. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. The distal semimembranosus complex: normal MR anatomy, variants, biomechanics and pathology

    International Nuclear Information System (INIS)

    Beltran, Javier; Jbara, Marlena; Maimon, Ron; Matityahu, Amir; Hwang, Ki; Padron, Mario; Mota, Javier; Beltran, Luis; Sundaram, Murali

    2003-01-01

    To describe the normal MR anatomy and variations of the distal semimembranosus tendinous arms and the posterior oblique ligament as seen in the three orthogonal planes, to review the biomechanics of this complex and to illustrate pathologic examples. The distal semimembranosus tendon divides into five tendinous arms named the anterior, direct, capsular, inferior and the oblique popliteal ligament. These arms intertwine with the branches of the posterior oblique ligament in the posterior medial aspect of the knee, providing stability. This tendon-ligamentous complex also acts synergistically with the popliteus muscle and actively pulls the posterior horn of the medial meniscus during knee flexion. Pathologic conditions involving this complex include complete and partial tears, insertional tendinosis, avulsion fractures and bursitis. (orig.)

  17. The distal semimembranosus complex: normal MR anatomy, variants, biomechanics and pathology

    Energy Technology Data Exchange (ETDEWEB)

    Beltran, Javier; Jbara, Marlena; Maimon, Ron [Department of Radiology, Maimonides Medical Center, 4802 Tenth Avenue, NY 11219, Brooklyn (United States); Matityahu, Amir; Hwang, Ki [Department of Orthopedic Surgery, Maimonides Medical Center, Brooklyn, NY (United States); Padron, Mario [Department of Radiology, Clinica CEMTRO, Madrid (Spain); Mota, Javier [Department of Radiology, Instituto Clinica Corachan, Barcelona (Spain); Beltran, Luis [New York Medical College, Valhalla, NY (United States); Sundaram, Murali [Department of Radiology, Mayo Clinic, Rochester, MN (United States)

    2003-08-01

    To describe the normal MR anatomy and variations of the distal semimembranosus tendinous arms and the posterior oblique ligament as seen in the three orthogonal planes, to review the biomechanics of this complex and to illustrate pathologic examples. The distal semimembranosus tendon divides into five tendinous arms named the anterior, direct, capsular, inferior and the oblique popliteal ligament. These arms intertwine with the branches of the posterior oblique ligament in the posterior medial aspect of the knee, providing stability. This tendon-ligamentous complex also acts synergistically with the popliteus muscle and actively pulls the posterior horn of the medial meniscus during knee flexion. Pathologic conditions involving this complex include complete and partial tears, insertional tendinosis, avulsion fractures and bursitis. (orig.)

  18. Clinico-radiographic Studies on The Prevalent Distal Limb Affections in Working Equine at Luxor City

    Directory of Open Access Journals (Sweden)

    A. A.A. Abdel-Hady

    2017-01-01

    Full Text Available To illustrate the clinical and radiographic findings of some distal limbs affections in Ninety two animals (24 horses and 68 donkeys which were admitted to Animal Care Hospital in Luxor. Each animal was subjected to thorough clinical and radiographic examination; the grade of lameness was recorded and the best radiographic views were taken.  Fifteen types of distal limb affections were evident. The most prevalent affections in donkeys were high and low ring bone (29.35% and hoof abscess ( 9.78% followed by traumatic arthritis of the fetlock (6.52%, suspensory ligament desmitis (5.43%, fracture of first phalanx (5.43%, fracture of PII (4.35%, side bone (3.26%  whereas, fracture of metacarpal bone (1.09%, sesamoditis (1.09% and flexural deformities (1.09%  represented the lowest prevalent affections.On the other hand, side bone (4.35%, fracture of the metacarpal bone (4.35% represented the most prevalent affections in horses followed by high and low ring bone (3.26%, fractures of PI (2.17%, PII (2.17%, subluxation of coronopedal joint (2.17% and punctured wounds in of the hoof (2.17%, traumatic arthritis of the fetlock joint (2.17%. Whereas, navicular disease (1.09%, suspensory ligament desmitis (1.09% and hoof abscess (1.09% were the lowest prevalent affections in horses. Treatment was not recommended in certain cases. In conclusion, although the wide stride progress have made in diagnostic imaging in recent decades, the x ray still offers a satisfactory tool for diagnostic imaging in equine limb practice that is useful for equine practitioners.

  19. Patellar Sleeve Fracture With Ossification of the Patellar Tendon.

    Science.gov (United States)

    Damrow, Derek S; Van Valin, Scott E

    2017-03-01

    Patellar sleeve fractures make up greater than 50% of all patellar fractures. They are essentially only seen in the pediatric population because of the thick periosteum and the distal patellar pole apophysis in this group. These fractures can lead to complications if not treated appropriately and in a timely fashion. Complications of missed or untreated patellar sleeve fractures include patella alta, anterior knee pain, and quadriceps atrophy. These can all result in severe limitations in activity. The authors describe a case of a 16-year-old boy who sustained a patellar sleeve fracture 3 years prior to presentation. On presentation, he had patella alta, diminished strength, 5° of extensor lag, and radiographs that revealed bone formation along the patellar tendon. Despite this, he was able to maintain a high level of activity. This case report explores how the patient could have maintained a high level of activity despite having a patellar sleeve fracture. Also, because of the delayed presentation, the patella was ossified and the quadriceps was retracted, which led to a novel approach to reconstructing his distal extensor mechanism. This approach included a V-Y advancement of the quadriceps tendon and patellar tendon reconstruction using the patient's hamstring tendon (semitendinosus). This technique, combined with physical therapy postoperatively, resulted in his return to varsity high school soccer. To the best of the authors' knowledge, this technique has not been reported for this rare condition. [Orthopedics. 2017; 40(2):e357-e359.]. Copyright 2016, SLACK Incorporated.

  20. Imaging of the elbow in children with wrist fracture: an unnecessary source of radiation and use of resources?

    International Nuclear Information System (INIS)

    Golding, Lauren P.; Yasin, Yousef; Singh, Jasmeet; Anthony, Evelyn; Gyr, Bettina M.; Gardner, Alison

    2015-01-01

    Anecdotally accepted practice for evaluation of children with clinically suspected or radiographically proven wrist fracture in many urgent care and primary care settings is concurrent imaging of the forearm and elbow, despite the lack of evidence to support additional images. These additional radiographs may be an unnecessary source of radiation and use of health care resources. Our study assesses the necessity of additional radiographs of the forearm and elbow in children with wrist injury. We reviewed electronic medical records of children 17 and younger in whom wrist fracture was diagnosed in the emergency department. We identified the frequency with which additional radiographs of the proximal forearm and distal humerus demonstrated another site of acute injury. We identified 214 children with wrist fracture. Of those, 129 received additional radiographs of the elbow. Physical examination findings proximal to the wrist were documented in only 16 (12%) of these 129 children. A second injury proximal to the wrist fracture was present in 4 (3%) of these 129 children, all of whom exhibited physical examination findings at the elbow. No fractures were documented in children with a negative physical examination of the elbow. Although elbow fractures occasionally complicate distal forearm fractures in children, our findings indicate that a careful physical evaluation of the elbow is sufficient to guide further radiographic investigation. Routine radiographs of both the wrist and elbow in children with distal forearm fracture appear to be unnecessary when an appropriate physical examination is performed. (orig.)