  1. Distal protection filter device efficacy with carotid artery stenting: comparison between a distal protection filter and a distal protection balloon.

    Science.gov (United States)

    Iko, Minoru; Tsutsumi, Masanori; Aikawa, Hiroshi; Matsumoto, Yoshihisa; Go, Yoshinori; Nii, Kouhei; Abe, Gorou; Ye, Iwae; Nomoto, Yasuyuki; Kazekawa, Kiyoshi

    2013-01-01

    This retrospective study aimed to compare the effectiveness of the embolization prevention mechanism of two types of embolic protection device (EPD)-a distal protection balloon (DPB) and a distal protection filter (DPF). Subjects were 164 patients scheduled to undergo carotid artery stenting: a DPB was used in 82 cases (DPB group) from April 2007 until June 2010, and a DPF was used in 82 cases (DPF group) from July 2010 to July 2011. Rates of positive findings on postoperative diffusion-weighted imaging (DWI) and stroke incidence were compared. Positive postoperative DWI results were found in 34 cases in the DPB group (41.4 %), but in only 22 cases in the DPF group (26.8 %), and there was only a small significant difference within the DPF group. In the DPB group, there was one case of transient ischemic attack (TIA) (1.2 %) and four cases of brain infarction (2 minor strokes, 2 major strokes; 4.9 %), compared to the DFP group with one case of TIA (1.2 %) and no cases of minor or major strokes. In this study, significantly lower rates of occurrence of DWI ischemic lesions and intraoperative embolization were associated with use of the DPF compared to the DPB.

  2. Cerebral Ischemia Detected with Diffusion-Weighted MR Imaging after Protected Carotid Artery Stenting: Comparison of Distal Balloon and Filter Device

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Suk Jung; Jeon, Pyoung [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Roh, Hong Gee [Konkuk University Hospital, Seoul (Korea, Republic of)] (and others)

    2007-08-15

    The aim of this study was to examine the incidence of ischemia during protected carotid artery stenting (CAS) as well as to compare the protective efficacy of the balloon and filter devices on diffusion-weighted MR imaging (DWI). Seventy-one consecutive protected CAS procedures in 70 patients with a severe (> 70%) or symptomatic moderate (> 50%) carotid artery stenosis were examined. A balloon device (PercuSurge GuardWire) and a filter device (FilterWire EX/EZ, Emboshield) was used in 33 cases (CAS-B group) and 38 cases (CAS-F group) to prevent distal embolization, respectively. All the patients underwent DWI within seven days before and after the procedures. The number of new cerebral ischemic lesions on the post-procedural DWI were counted and divided into ipsilateral and contralateral lesions according to the relationship with the stenting side. New cerebral ischemic lesions were detected in 13 (39.4%) out of the 33 CAS-Bs and in 15 (39.5%) out of the 38 CAS-Fs. The mean number of total, ipsilateral and contralateral new cerebral ischemic lesion was 2.39, 1.67 and 0.73 in the CAS-B group and 2.11, 1.32 and 0.79 in the CAS-F group, respectively. No statistical differences were found between the two groups (p = 0.96, 0.74 and 0.65, respectively). The embolic complications encountered included two retinal infarctions and one hemiparesis in the CAS-B group (9.09%), and one retinal infarction, one hemiparesis and one ataxia in the CAS-F group (7.89%). There was a similar incidence of embolic complications in the two groups (p 1.00). The type of distal protection device used such as a balloon and filter does not affect the incidence of cerebral embolization after protected CAS.

  3. Distal protection in cardiovascular medicine: current status.

    Science.gov (United States)

    Ali, Onn Akbar; Bhindi, Ravinay; McMahon, Aisling C; Brieger, David; Kritharides, Leonard; Lowe, Harry C

    2006-08-01

    Iatrogenic and spontaneous downstream microembolization of atheromatous material is increasingly recognized as a source of cardiovascular morbidity and mortality. Devising ways of reducing this distal embolization using a variety of mechanical means--distal protection--is currently under intense and diverse investigation. This review therefore summarizes the present status of distal protection. It examines the problem of distal embolization, describes the available distal protection devices, reviews those areas of cardiovascular medicine where distal protection devices are being investigated, and discusses potential future developments.

  4. Distal Embolic Protection for Renal Arterial Interventions

    International Nuclear Information System (INIS)

    Dubel, Gregory J.; Murphy, Timothy P.

    2008-01-01

    Distal or embolic protection has intuitive appeal for its potential to prevent embolization of materials generated during interventional procedures. Distal protection devices (DPDs) have been most widely used in the coronary and carotid vascular beds, where they have demonstrated the ability to trap embolic materials and, in some cases, to reduce complications. Given the frequency of chronic kidney disease in patients with renal artery stenosis undergoing stent placement, it is reasonable to propose that these devices may play an important role in limiting distal embolization in the renal vasculature. Careful review of the literature reveals that atheroembolization does occur during renal arterial interventions, although it often goes undetected. Early experience with DPDs in the renal arteries in patients with suitable anatomy suggests retrieval of embolic materials in approximately 71% of cases and renal functional improvement/stabilization in 98% of cases. The combination of platelet inhibition and a DPD may provide even greater benefit. Given the critical importance of renal functional preservation, it follows that everything that can be done to prevent atheroembolism should be undertaken including the use of DPDs when anatomically feasible. The data available at this time support a beneficial role for these devices

  5. Analysis of emboli during carotid stenting with distal protection device.

    Science.gov (United States)

    Chen, Chin-I; Iguchi, Yasuyuki; Garami, Zsolt; Malkoff, Marc D; Smalling, Richard W; Campbell, Morgan S; Alexandrov, Andrei V

    2006-01-01

    The newly developed multi-frequency transcranial Doppler (TCD) is able to differentiate gaseous from solid emboli. Our goal was to apply this technology to initially characterize emboli detected during carotid stenting with distal protection. Patients undergoing carotid angiography and stenting were monitored with 2-2.5 MHz TCD (Embo-Dop, DWL) over the middle cerebral artery unilateral to stent deployment. Sonographers insured optimal signal recordings during the procedures. Automated emboli detection and classification software (MultiXLab version 2.0) was applied for offline count and analysis. Monitoring using the Filter Wire EX (Boston Scientific) and ACCUNET system (Guidant Corporation) was performed. A total of 9,649 embolic signals were detected during 11 angiographic and 10 stenting procedures. An observer confirmed the signals using the International Consensus definition. Automated software classified these events into 5,900 gaseous and 3,749 solid emboli. During contrast injections without the protection device, 1,013 emboli were detected with 28% of these being solid. With deployment of the distal protection device, 8,636 emboli were found with 40% being solid (p protection device, 7,395 emboli with 42% solids were detected (p protection device still deployed, yielded 1,241 emboli with 31% solids (NS). Only 1 patient developed transient hemiparesthesia during ballooning that reduced the flow velocity to zero for 14 s. Neither gaseous nor solid emboli resulted in a mean flow velocity decrease or clinical symptoms. Microembolization frequently occurs during stenting even with deployment of the distal protection device. More solid emboli are seen during manipulations associated with lesion crossing. Although novel TCD methods yield a high frequency of embolic signals, further validation of this technique to determine the true nature, size, and number of emboli is needed.

  6. Vertebral artery origin stent placement with distal protection: technical and clinical results.

    Science.gov (United States)

    Qureshi, A I; Kirmani, J F; Harris-Lane, P; Divani, A A; Ahmed, S; Ebrihimi, A; Al Kawi, A; Janjua, N

    2006-05-01

    To report the feasibility, safety, and 1-month results of performing stent placement for vertebral origin stenosis with the use of a distal protection device. Distal protection devices have been shown to reduce the number of cerebral emboli and subsequent ischemic events when used as adjuncts to percutaneous carotid intervention; however, one case of the use of a distal protection device for vertebral artery has been reported in the literature. We retrospectively determined rates of technical success and 1-month stroke or death associated with stent placement by using distal protection (Filter EX; Boston Scientific, Natick, Mass) in patients with symptomatic vertebral artery origin stenosis. Technical success was defined as successful deployment of distal protection device and stent at target lesion followed by successful retrieval of the device and a final residual stenosis of less than 30%. Other outcomes ascertained included any stroke, death, and semiquantitative assessment of particulate material retained by the filter device. The mean age of the 12 treated patients was 68 years (range, 52-88 years) and the group included 9 men and 3 women. The mean percentage of vertebral artery origin stenosis was 71 +/- 6%. Femoral and radial approaches were used in 9 and 3 cases, respectively. Technical success was achieved in 11 of the 12 patients in whom distal protection device placement was attempted. Postprocedure residual stenosis was 5 +/- 4%. Eight devices held macroscopically visible embolic debris (large and small amounts in 3 and 5 devices, respectively). No stroke or death was observed in the 1-month follow-up. The present study demonstrates the feasibility of performing stent placement for vertebral artery origin stenosis by using a distal protection device. Further studies are required to determine the effectiveness of this approach for vertebral artery origin atherosclerosis.

  7. Increased rate of stent thrombosis and target lesion revascularization after filter protection in primary percutaneous coronary intervention for ST-segment elevation myocardial infarction: 15-month follow-up of the DEDICATION (Drug Elution and Distal Protection in ST Elevation Myocardial Infarction) trial

    DEFF Research Database (Denmark)

    Kaltoft, Anne; Kelbaek, Henning; Kløvgaard, Lene

    2010-01-01

    The purpose of this study was to evaluate the long-term effects of distal protection during percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI).......The purpose of this study was to evaluate the long-term effects of distal protection during percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI)....

  8. Safety and Effectiveness of the Nav-6 Filter in Preventing Distal Embolization During Jetstream Atherectomy of Infrainguinal Peripheral Artery Lesions.

    Science.gov (United States)

    Banerjee, Avantika; Sarode, Karan; Mohammad, Atif; Brilakis, Emmanouil S; Banerjee, Subhash; Shammas, Gail A; Shammas, Nicolas W

    2016-08-01

    The risk of distal embolization (DE) during infrainguinal peripheral artery interventions (PAI) is often mitigated by the use of embolic protection devices. There are limited data on the use of filters with the Jetstream (JS) atherectomy device, a rotational cutter with aspiration capacity. The Nav-6 filter is uniquely suited for use with the JS due to its wire compatibility and detachment from the filter; however, data on the off-label use of this combination have not been reported. Consecutive patients between October 2008 and April 2015 undergoing endovascular infrainguinal PAI with JS were analyzed as part of the Excellence in Peripheral Artery Disease (XL-PAD) registry (NCT01904851). Patients were divided into two subgroups with Nav-6 filter use vs no filter use. Descriptive and univariate analyses were performed. Among 141 patients (mean age, 67.8 ± 10.8 years; 169 lesions) included in this study, the Nav-6 filter was used in 82 (59%). Use of a filter was more frequent in longer lesions (146 ± 106 mm vs 91 ± 72 mm; P=.01), in more severe stenoses (95% vs 87%; P=.04), and in chronic total occlusions (33% vs 8.3%; P=.01). Patients receiving filters had longer procedure duration (102 ± 51 min vs 66 ± 41 min; P=.01) and longer fluoroscopy times (31 ± 16 min vs 21 ± 10 min; Patherectomy was predominantly used during complex infrainguinal PAI and was associated with less occurrence of DE.

  9. Transcranial Doppler monitoring during stenting of the carotid bifurcation: evaluation of two different distal protection devices in preventing embolization.

    Science.gov (United States)

    Rubartelli, Paolo; Brusa, Giulia; Arrigo, Alessandro; Abbadessa, Francesco; Giachero, Corinna; Vischi, Massimo; Ricca, Maria Maddalena; Ottonello, Gian Andrea

    2006-08-01

    To compare the efficacy of 2 emboli protection devices in preventing embolization during carotid artery stenting (CAS). The GuardWire distal occlusion system (n=19) and the distal FilterWire EX (n=12) were compared in 31 consecutive patients (24 men; mean age 71+/-10 years) monitored with transcranial Doppler for microembolic signals before, during, and after CAS. The choice of the protection device was based on availability and on the patency of the contralateral carotid artery. The baseline characteristics were similar in the patients treated under protection from either device. Placement and retrieval of the protection device, stenting, and postdilation were technically successful in all patients. Two patients suffered a transient ischemic attack shortly after the procedure; no other adverse cardiovascular events occurred at 30 days. Compared to the GuardWire, the use of the FilterWire was associated with more microembolic signals during stent deployment (77.4+/-33.5 versus 1.07+/-1.94, pprotection device (21.4+/-15.4 versus 10.9+/-8.3, p=0.051). Consequently, the total amount of microembolic signals during the procedure was higher when the filter device was employed (183.0+/-42.1 versus 31.7+/-12.0, p<0.0001). The distal occlusion device appears to be more effective than the filter in reducing distal embolization detected by transcranial Doppler monitoring.

  10. Retinal artery occlusion during carotid artery stenting with distal embolic protection device.

    Science.gov (United States)

    Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu

    2018-01-01

    Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.

  11. Left ventricular contractile function after distal protection in primary percutaneous coronary intervention Results from the Drug Elution and Distal Protection in ST-Elevation Myocardial Infarction trial

    DEFF Research Database (Denmark)

    Kofoed, K F; Kelbæk, H; Thuesen, L

    2011-01-01

    Coronary intervention (PCI) may result in an increased infarct size. We evaluated the effect of distal protection during PCI for ST-segment elevation myocardial infarction (STEMI) on myocardial function.......Coronary intervention (PCI) may result in an increased infarct size. We evaluated the effect of distal protection during PCI for ST-segment elevation myocardial infarction (STEMI) on myocardial function....

  12. Subclinical ischemic events in patients undergoing carotid artery stent placement: comparison of proximal and distal protection techniques.

    Science.gov (United States)

    Aytac, Emrah; Gürkaş, Erdem; Akpinar, Cetin Kursad; Saleem, Muhammad A; Qureshi, Adnan I

    2017-10-01

    To determine the relative effectiveness of proximal and distal protection in prevention of cerebral ischemic events during carotid artery stent (CAS) placement using diffusion-weighted MRI (DW-MRI). We analyzed data from patients who had undergone DW-MRI before and within 24 hours of CAS for symptomatic internal carotid artery (ICA) stenosis (with last ischemic events within 3 months). The study was performed prospectively; patients were not randomized, and were treated either with a proximal balloon occlusion system (Mo.Ma; Invatec, Roncadelle, Italy) or filter-type distal protection device (Spider device; ev3, Plymouth, Minnesota, USA). Of the 45 patients (mean age±SD: 66.9±9.8 years; 73.3% were men) who underwent CAS, 19 had proximal protection and 26 distal protection. New ischemic lesions were detected in 26/45 patients on DW-MRI scans obtained within 24 hours after CAS. The proportion of patients with new lesions on DW-MRI at 24 hours was not different between the two groups (47.4% vs 65.4% for proximal and distal protection, respectively). The mean number of new ischemic lesions on post-CAS DW-MRI was non-significantly higher in patients who underwent CAS with distal protection (2.80±3.54 for proximal protection vs 4.96±5.11 for distal protection; p=0.12). The proportion of patients with new lesions >1 cm did not differ between the two groups (5.3% for proximal protection vs 11.5% for distal protection; p=0.62). There was no difference in the rates of ischemic stroke between patients who underwent CAS treatment using proximal and distal protection (5.3% vs 7.7%; p=1.000). We found a relatively high rate of new ischemic lesions in patients undergoing CAS with cerebral protection. There was no difference in the proportion of patients with new lesions between patients treated using distal protection and those treated using proximal protection. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a

  13. Nitinol Embolic Protection Filters: Design Investigation by Finite Element Analysis

    Science.gov (United States)

    Conti, Michele; de Beule, Matthieu; Mortier, Peter; van Loo, Denis; Verdonck, Pascal; Vermassen, Frank; Segers, Patrick; Auricchio, Ferdinando; Verhegghe, Benedict

    2009-08-01

    The widespread acceptance of carotid artery stenting (CAS) to treat carotid artery stenosis and its effectiveness compared with surgical counterpart, carotid endarterectomy (CEA), is still a matter of debate. Transient or permanent neurological deficits may develop in patients undergoing CAS due to distal embolization or hemodynamic changes. Design, development, and usage of embolic protection devices (EPDs), such as embolic protection filters, appear to have a significant impact on the success of CAS. Unfortunately, some drawbacks, such as filtering failure, inability to cross tortuous high-grade stenoses, malpositioning and vessel injury, still remain and require design improvement. Currently, many different designs of such devices are available on the rapidly growing dedicated market. In spite of such a growing commercial interest, there is a significant need for design tools as well as for careful engineering investigations and design analyses of such nitinol devices. The present study aims to investigate the embolic protection filter design by finite element analysis. We first developed a parametrical computer-aided design model of an embolic filter based on micro-CT scans of the Angioguard™ XP (Cordis Endovascular, FL) EPD by means of the open source pyFormex software. Subsequently, we used the finite element method to simulate the deployment of the nitinol filter as it exits the delivery sheath. Comparison of the simulations with micro-CT images of the real device exiting the catheter showed excellent correspondence with our simulations. Finally, we evaluated circumferential basket-vessel wall apposition of a 4 mm size filter in a straight vessel of different sizes and shape. We conclude that the proposed methodology offers a useful tool to evaluate and to compare current or new designs of EPDs. Further simulations will investigate vessel wall apposition in a realistic tortuous anatomy.

  14. Efficiency and safety of percuSurge distal protection device in acute ...

    African Journals Online (AJOL)

    user

    2011-04-25

    Apr 25, 2011 ... myocardial infarction. The long-term effects of the distal protection device are still in controversy. The enhanced myocardial efficacy and recovery by aspiration of liberated debris (EMERALD) trial failed to show the effectiveness of the distal protection device in patients with AMI (Yamada and Topol, 2000).

  15. Final Results of the Protected Superficial Femoral Artery Trial Using the FilterWire EZ System

    International Nuclear Information System (INIS)

    Mueller-Huelsbeck, Stefan; Huemme, Tim H.; Philipp Schaefer, J.; Charalambous, Nikolas; Paulsen, Friedrich; Heller, Martin; Jahnke, Thomas

    2010-01-01

    The purpose of this study was to evaluate the safety and efficacy of debris-capture for distal protection using the FilterWire EZ Embolic Protection System (Boston Scientific, Mountain View, CA) with the additional aim to further define the incidence of distal embolization during superficial femoral artery (SFA) interventions. A prospective, single-centre registry was designed to evaluate the performance of the FilterWire EZ in capturing debris during standard SFA percutaneous intervention. The PRO-RATA study included 30 patients suitable for PTA (Fontaine IIb to III or Rutherford I to II classification). The primary end points were occurrence of distal embolization or decreased runoff, improvement in ankle-brachial index ankle-brachial index (ABI) after the procedure, and number of filters containing emboli. Secondary end points included major adverse events (i.e., procedure- or device-related death and/or clinical target lesion revascularisation), device delivery, deployment success, and incidence of embolic recovery (patients with device success exhibiting embolic protection in the filter). Procedural success was determined as ≤30% residual stenosis with no worsening of distal runoff as determined on angiography. A total of 29 patients (age 66.2 ± 12 years; total no. of limbs = 30; total no. of lesions = 30) suitable for PTA were enrolled in the study between February 2007 and March 2008. There were 26 patients with claudication (Fontaine IIB) and 3 patients with stage IV peripheral vascular disease. In one patient, lesions in both legs were treated. No procedural or device-related complications occured. The average degree of stenosis was 86 ± 7%. Stenosis length ranged from 8 to 88 mm. The average degree of residual stenosis was 10 ± 10%. ABI improved from 0.56 ± 0.16 to 0.92 ± 0.19 (P < 0.05). No restenosis or dissection was seen at 1-month ultrasound follow-up. Macroscopic debris was found in 27 of 30 filters of all distal protection devices used in

  16. Randomized comparison of distal protection versus conventional treatment in primary percutaneous coronary intervention: the drug elution and distal protection in ST-elevation myocardial infarction (DEDICATION) trial

    DEFF Research Database (Denmark)

    Kelbaek, Henning; Terkelsen, Christian J; Helqvist, Steffen

    2008-01-01

    OBJECTIVES: The purpose of this study was to evaluate the use of distal protection during percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI) in native coronary vessels. BACKGROUND: Embolization of material from the infarct-related lesion during PCI may...

  17. Outflow protection filters during percutaneous recanalization of lower extremities' arterial occlusions: a pilot study

    International Nuclear Information System (INIS)

    Siablis, Dimitrios; Karnabatidis, Dimitrios; Katsanos, Konstantinos; Ravazoula, Panagiota; Kraniotis, Pantelis; Kagadis, George C.

    2005-01-01

    Purpose: Filter devices are already employed for the protection of carotid, coronary and renal distal vascular bed during endovascular procedures. This is a pilot study investigating their feasibility, safety and distal emboli protection capability during recanalization of lower extremities' acute and subacute occlusions. Materials and methods: Study population included 16 patients, 11 with a subacute arterial occlusion and 5 with an acute episode. The Trap filter (Microvena, USA) and its successor the Spider filter (EV3, USA) were utilized. Subacute occlusions were dealt with standard angioplasty and stenting procedures, while acute ones were managed primarily with Angiojet rheolytic thrombectomy. Outflow arterial tree was checked angiographically in-between consequent procedural steps. Embolic material collected after filter recovery was analyzed histopathologically. Patients' follow-up was scheduled at 1 month. Results: Seventeen filter baskets were applied in the recanalization of 16 target lesions in total. Mean length of the occluded segments was 6.1 (range: 2-15 cm; S.D. = 3.7 cm). Mean in situ time of the filters was 38.75 min (range: 20-60 min; S.D. 12.71 min). Technical success rate of deployment and utilization of the filtration devices was 100% (17/17). Procedural success rate of the recanalization was 100% (16/16) without any clinical or angiographic evidence of periprocedural distal embolization. Macroscopic particulate debris was extracted from all the filters (17/17) containing fresh thrombus, calcification minerals, cholesterol and fibrin. Mean diameter of the largest particle per specimen was 1702.80 (range: 373.20-4680.00 μm; S.D. 1155.12 μm). No adverse clinical events occurred at 1-month follow-up with 100% limb salvage (16/16). Conclusion: The application of outflow protection filters is safe, feasible and efficacious in hindering distal embolization complications and safeguarding the distal capillary bed. Nevertheless, this is a pilot study

  18. Optical Protection Filters for Harmful Laser Beams and UV Radiation

    Science.gov (United States)

    Azim M., Osama A.

    2007-02-01

    Due to the rapid growth of radiation protection applications in various devices and instruments, it is essential to use suitable filters for eye protection of the personal working in the radiation field. Different protection filters were produced to protect from four laser beam wavelengths (at 532nm, 632.8nm, 694nm and 1064nm) and block three UV bands (UVA, UVB, and UVC). The design structure of the required dielectric multilayer filters used optical thin film technology. The computer analyses of the multilayer filter formulas were prepared using Macleod Software for the production filter processes. The deposition technique was achieved on optical substrates (Glass BK-7 and Infrasil 301) by dielectric material combinations including Dralo (mixture of oxides TiO2/Al2O3), and Lima (mixture of oxides SiO2/Al2O3); deposition by an electron beam gun. The output transmittance curves for both theoretical and experimental values of all filters are presented. To validate the suitability for use in a `real world', rather than laboratory test application, full environmental assessment was also carried out. These filters exhibited high endurance after exposing them to the durability tests (adhesion, abrasion resistance and humidity) according to military standards MIL-C-675C and MIL-C-48497A.

  19. Optical Protection Filters for Harmful Laser Beams and UV Radiation

    International Nuclear Information System (INIS)

    Azim M, Osama A.

    2007-01-01

    Due to the rapid growth of radiation protection applications in various devices and instruments, it is essential to use suitable filters for eye protection of the personal working in the radiation field. Different protection filters were produced to protect from four laser beam wavelengths (at 532nm, 632.8nm, 694nm and 1064nm) and block three UV bands (UVA, UVB, and UVC). The design structure of the required dielectric multilayer filters used optical thin film technology. The computer analyses of the multilayer filter formulas were prepared using Macleod Software for the production filter processes. The deposition technique was achieved on optical substrates (Glass BK-7 and Infrasil 301) by dielectric material combinations including Dralo (mixture of oxides TiO2/Al2O3), and Lima (mixture of oxides SiO2/Al2O3); deposition by an electron beam gun. The output transmittance curves for both theoretical and experimental values of all filters are presented. To validate the suitability for use in a 'real world', rather than laboratory test application, full environmental assessment was also carried out. These filters exhibited high endurance after exposing them to the durability tests (adhesion, abrasion resistance and humidity) according to military standards MIL-C-675C and MIL-C-48497A

  20. Biobased Nanoparticles for Broadband UV Protection with Photostabilized UV Filters

    NARCIS (Netherlands)

    Hayden, D.R.|info:eu-repo/dai/nl/412640694; Imhof, A.|info:eu-repo/dai/nl/145641600; Velikov, K. P.|info:eu-repo/dai/nl/239483472

    2016-01-01

    Sunscreens rely on multiple compounds to provide effective and safe protection against UV radiation. UV filters in sunscreens, in particular, provide broadband UV protection but are heavily linked to adverse health effects due to the generation of carcinogenic skin-damaging reactive oxygen species

  1. Determination of permeability of ultra-fine cupric oxide aerosol through military filters and protective filters

    Science.gov (United States)

    Kellnerová, E.; Večeřa, Z.; Kellner, J.; Zeman, T.; Navrátil, J.

    2018-03-01

    The paper evaluates the filtration and sorption efficiency of selected types of military combined filters and protective filters. The testing was carried out with the use of ultra-fine aerosol containing cupric oxide nanoparticles ranging in size from 7.6 nm to 299.6 nm. The measurements of nanoparticles were carried out using a scanning mobility particle sizer before and after the passage through the filter and a developed sampling device at the level of particle number concentration approximately 750000 particles·cm-3. The basic parameters of permeability of ultra-fine aerosol passing through the tested material were evaluated, in particular particle size, efficiency of nanoparticle capture by filter, permeability coefficient and overall filtration efficiency. Results indicate that the military filter and particle filters exhibited the highest aerosol permeability especially in the nanoparticle size range between 100–200 nm, while the MOF filters had the highest permeability in the range of 200 to 300 nm. The Filter Nuclear and the Health and Safety filter had 100% nanoparticle capture efficiency and were therefore the most effective. The obtained measurement results have shown that the filtration efficiency over the entire measured range of nanoparticles was sufficient; however, it was different for particular particle sizes.

  2. Sheath rendezvous method: a novel distal protection technique during endovascular treatment of subclavian artery occlusions.

    Science.gov (United States)

    Haraguchi, Takuya; Urasawa, Kazushi; Nakama, Tatsuya; Nakagawa, Yuya; Tan, Michinao; Koshida, Ryoji; Sato, Katsuhiko

    2016-10-01

    To describe an innovative distal protection technique, "sheath rendezvous method", during endovascular treatment for subclavian arterial occlusions. 4.5F and 6F guiding sheath were inserted from left brachial and common femoral artery, respectively. 0.014″ guidewire retrogradely passed through occlusion and into antegrade sheath to establish a pull-through system. 3.0 mm balloon was used to expand occlusion and anchor to deliver retrograde sheath into antegrade one. Both sheaths locked by balloon dilatation crossed occlusion until antegrade sheath passed over lesion. Balloon expandable stent was delivered within antegrade sheath. Sheath was removed, and stent was implanted. We obtained an excellent outcome without complications.

  3. DIGITAL FILTERS IMPLEMENTATION IN MICROPROCESSOR-BASED RELAY PROTECTION

    Directory of Open Access Journals (Sweden)

    Yu. V. Rumiantsev

    2016-01-01

    Full Text Available This article presents the implementation of digital filters used in digital relay protection current measuring elements. Mathematical descriptions of the considered digital filters as well as the computer programs for their coefficients calculation are described. It has been shown that in order to reliable estimate the digital filter performance its input signals waveforms must be close to the actual secondary current waveform of the current transformer to which the digital protection with the estimated digital filter is connected. For these purposes in MatLab–Simulink dynamic simulation environment the power system and the current measuring element models were developed. Performed calculations allowed to reveal that the exponentially decaying DC component which in some cases contains in primary fault current drives the current transformer core into saturation even when its nominal parameters are not exceeded. This results in distortion of the current transformer secondary current which in this case contains higher and inter-harmonics. Moreover, such harmonic content is not completely taking into account during coefficients calculation of the considered digital filters what results in signal magnitude estimation inaccuracy. Comparison of the digital filters response to the above-mentioned input signals allowed to find out such digital filter implementations which enable signal magnitude estimation with a minimum error. Ways of filtering quality improvement concerned with the window functions are proposed. Thus, the joint usage of digital filter and Hamming window allows to achieve the zero value of the signal magnitude gain factor in high-frequency range and substantially suppress all spectral components above 100 Hz. The increasing of the signal magnitude settling time in this case can be reduced by choosing the most optimal parameters of the all components of the current measuring element.

  4. Purification yields of forced air filters for radioactive breath protection

    International Nuclear Information System (INIS)

    Landman, E.B.

    1986-01-01

    Air filters for breath protection were tested as to purification yield using the in-situ DOP testing method. Only some of them satisfied the requirements made by the authors. Requirements, testing methods, experimental set-up and results are presented. (G.J.P.)

  5. Carotid Stenting with Distal Protection in High-Surgical-Risk Patients: One-Year Results of the ASTI Trial

    Energy Technology Data Exchange (ETDEWEB)

    Bosiers, Marc, E-mail: marc.bosiers@telenet.be [A.Z. Sint-Blasius, Department of Vascular Surgery (Belgium); Scheinert, Dierk, E-mail: dierk.scheinert@gmx.de [Park Hospital, Center for Vascular Medicine-Angiology and Vascular Surgery (Germany); Mathias, Klaus, E-mail: k.mathias@asklepios.com [Klinikum Dortmund GmbH (Germany); Langhoff, Ralf, E-mail: ralf.langhoff@sankt-gertrauden.de [Sankt Gertrauden-Krankenhaus (Germany); Mudra, Harald, E-mail: haraldmudra@aol.com [Klinikum Neuperlach (Germany); Diaz-Cartelle, Juan, E-mail: juan.diazcartelle@bostonscientific.com [One Boston Scientific Place, Boston Scientific Corporation (United States)

    2015-04-15

    PurposeThis prospective, multicenter, nonrandomized study evaluated the periprocedural and 1-year outcomes in high-surgical-risk patients with carotid artery stenosis treated with the Adapt Carotid Stent plus FilterWire EZ distal protection catheter (Boston Scientific Corporation, Natick, MA).Materials and MethodsThe study enrolled 100 patients (32 symptomatic, 63 asymptomatic, 5 unknown) at high risk for carotid endarterectomy due to prespecified anatomical criteria and/or medical comorbidities. Thirty-day and 1-year follow-up included clinical evaluation, carotid duplex ultrasound, and independent neurologic and NIH stroke scale assessments. One-year endpoints included the composite rate of major adverse events (MAE), defined as death, stroke, and myocardial infarction (MI) and the rates of late ipsilateral stroke (31–365 days), target lesion revascularization, and in-stent restenosis.ResultsOf the 100 enrolled patients, technical success was achieved in 90.9 % (90/99). The 30-day MAE rate (5.1 %) consisted of major stroke (2.0 %) and minor stroke (3.1 %); no deaths or MIs occurred. The 1-year MAE rate (12.2 %) consisted of death, MI, and stroke rates of 4.4, 3.3, and 8.9 %, respectively. Late ipsilateral stroke (31–365 days) rate was 1.1 %. Symptomatic patients had higher rates of death (11.1 vs. 1.7 %) and MI (7.4 vs. 1.7 %), but lower rates of major (7.4 vs. 10.0 %) and minor stroke (0.0 vs. 6.7 %), compared with asymptomatic patients.ConclusionResults through 1 year postprocedure demonstrated that carotid artery stenting with Adapt Carotid Stent and FilterWire EZ is safe and effective in high-risk-surgical patients.

  6. Carotid Stenting with Distal Protection in High-Surgical-Risk Patients: One-Year Results of the ASTI Trial

    International Nuclear Information System (INIS)

    Bosiers, Marc; Scheinert, Dierk; Mathias, Klaus; Langhoff, Ralf; Mudra, Harald; Diaz-Cartelle, Juan

    2015-01-01

    PurposeThis prospective, multicenter, nonrandomized study evaluated the periprocedural and 1-year outcomes in high-surgical-risk patients with carotid artery stenosis treated with the Adapt Carotid Stent plus FilterWire EZ distal protection catheter (Boston Scientific Corporation, Natick, MA).Materials and MethodsThe study enrolled 100 patients (32 symptomatic, 63 asymptomatic, 5 unknown) at high risk for carotid endarterectomy due to prespecified anatomical criteria and/or medical comorbidities. Thirty-day and 1-year follow-up included clinical evaluation, carotid duplex ultrasound, and independent neurologic and NIH stroke scale assessments. One-year endpoints included the composite rate of major adverse events (MAE), defined as death, stroke, and myocardial infarction (MI) and the rates of late ipsilateral stroke (31–365 days), target lesion revascularization, and in-stent restenosis.ResultsOf the 100 enrolled patients, technical success was achieved in 90.9 % (90/99). The 30-day MAE rate (5.1 %) consisted of major stroke (2.0 %) and minor stroke (3.1 %); no deaths or MIs occurred. The 1-year MAE rate (12.2 %) consisted of death, MI, and stroke rates of 4.4, 3.3, and 8.9 %, respectively. Late ipsilateral stroke (31–365 days) rate was 1.1 %. Symptomatic patients had higher rates of death (11.1 vs. 1.7 %) and MI (7.4 vs. 1.7 %), but lower rates of major (7.4 vs. 10.0 %) and minor stroke (0.0 vs. 6.7 %), compared with asymptomatic patients.ConclusionResults through 1 year postprocedure demonstrated that carotid artery stenting with Adapt Carotid Stent and FilterWire EZ is safe and effective in high-risk-surgical patients

  7. Hybrid Plasma Reactor/Filter for Transportable Collective Protection Systems

    Energy Technology Data Exchange (ETDEWEB)

    Josephson, Gary B.; Tonkyn, Russell G.; Frye, J. G.; Riley, Brian J.; Rappe, Kenneth G.

    2011-04-06

    Pacific Northwest National Laboratory (PNNL) has performed an assessment of a Hybrid Plasma/Filter system as an alternative to conventional methods for collective protection. The key premise of the hybrid system is to couple a nonthermal plasma (NTP) reactor with reactive adsorption to provide a broader envelope of protection than can be provided through a single-solution approach. The first step uses highly reactive species (e.g. oxygen radicals, hydroxyl radicals, etc.) created in a nonthermal plasma (NTP) reactor to destroy the majority (~75% - 90%) of an incoming threat. Following the NTP reactor an O3 reactor/filter uses the O3 created in the NTP reactor to further destroy the remaining organic materials. This report summarizes the laboratory development of the Hybrid Plasma Reactor/Filter to protect against a ‘worst-case’ simulant, methyl bromide (CH3Br), and presents a preliminary engineering assessment of the technology to Joint Expeditionary Collective Protection performance specifications for chemical vapor air purification technologies.

  8. Design and development of laser eye protection filter

    International Nuclear Information System (INIS)

    Ahmed, K; Khan, A N; Rauf, A; Gul, A; Aslam, M

    2013-01-01

    Laser based devices, have been operational for measurement of distances horizontally and vertically in avionics and surveillance industries. These equipments are functional on pulsed Nd:YAG laser at 1064nm, this wavelength elevate the risk of eye exposure to personnel at unexpected levels. In this paper the eye protection filters, for the wavelength 1064nm were developed with soft (ZnS) and hard (TiO 2 ) coating materials by using thin film vacuum coating technique. The damage threshold of the filter is 0.2 J/cm 2 . Transmission characteristics are measured and discussed. Optical damage threshold (for eye 5 × 10 −6 J/cm2) at various distances is also simulated.

  9. Holographic diffraction gratings as laser radiation protection filters

    International Nuclear Information System (INIS)

    Pantelic, D.; Pantelic, G.

    2006-01-01

    Holographic volume diffraction gratings are used as attenuation filters, due to their selective spectral transmission. They can be tailored to reflect or transmit narrow spectral ranges by adjusting spatial frequency of Bragg grating in carefully chosen photosensitive materials, like silver-halide emulsion or di-chromated gelatin layers. If properly recorded and chemically processed, resulting gratings can significantly attenuate light at wavelengths corresponding to various laser spectral lines. Thus, they can be used as filters in laser protection goggles. We analyze the characteristics of Bragg gratings necessary to obtain high attenuation coefficients. Also, their angular selectivity is taken into account and corresponding experimental conditions are investigated. Although di-chromated gelatin seems to be almost ideal material, due to its almost 100% diffraction efficiency, environmental stability is poor (degradation under humid environment), thus making its practical usage difficult. Thus, we have analyzed alternative materials like di-chromated pullulan, which is stable under normal environmental conditions (without drop in diffraction efficiency after prolonged exposure to humidity). Pullulan is polymer (polysaccharide) of biologic origin produced by certain bacteria. If doped with chromium ions it becomes photosensitive, enabling recording of diffraction gratings with spatial frequency of more than 3000 lines/mm. Material is chemically processed by mixture of isopropyl alcohol and water. Both thick and thin layers can be produced by gravity settling. Spectral properties of resulting gratings are analyzed, showing that they can significantly attenuate laser light of particular wavelength, depending of grating period and its slant angle. (authors)

  10. Techniques in cerebral protection.

    Science.gov (United States)

    Fanelli, Fabrizio; Bezzi, Mario; Boatta, Emanuele; Passariello, Roberto

    2006-10-01

    Carotid angioplasty and stenting is a valid alternative option to conventional carotid endarterectomy in the treatment of carotid artery stenosis. During the stenting process, however, distal embolization can occur with neurological consequences. To avoid this, cerebral protection devices have been introduced. Three principal types of protection system have been developed: distal balloon occlusion, distal filters and proximal protection with or without reversal of flow. As protection devices became the focus of interest by manufactures and physicians, several trials are going on worldwide to analyze the characteristics of each of them and to evaluate their efficacy to reduce the rate of distal embolization.

  11. Complete filter-based cerebral embolic protection with transcatheter aortic valve replacement.

    Science.gov (United States)

    Van Gils, Lennart; Kroon, Herbert; Daemen, Joost; Ren, Claire; Maugenest, Anne-Marie; Schipper, Marguerite; De Jaegere, Peter P; Van Mieghem, Nicolas M

    2018-03-01

    To evaluate the value of left vertebral artery filter protection in addition to the current filter-based embolic protection technology to achieve complete cerebral protection during TAVR. The occurrence of cerebrovascular events after transcatheter aortic valve replacement (TAVR) has fueled concern for its potential application in younger patients with longer life expectancy. Transcatheter cerebral embolic protection (TCEP) devices may limit periprocedural cerebrovascular events by preventing macro and micro-embolization to the brain. Conventional filter-based TCEP devices cover three extracranial contributories to the brain, yet leave the left vertebral artery unprotected. Patients underwent TAVR with complete TCEP. A dual-filter system was deployed in the brachiocephalic trunk and left common carotid artery with an additional single filter in the left vertebral artery. After TAVR all filters were retrieved and sent for histopathological evaluation by an experienced pathologist. Eleven patients received a dual-filter system and nine of them received an additional left vertebral filter. In the remaining two patients, the left vertebral filter could not be deployed. No periprocedural strokes occurred. We found debris in all filters, consisting of thrombus, tissue derived debris, and foreign body material. The left vertebral filter contained debris in an equal amount of patients as the Sentinel filters. The size of the captured particles was similar between all filters. The left vertebral artery is an important entry route for embolic material to the brain during TAVR. Selective filter protection of the left vertebral artery revealed embolic debris in all patients. The clinical value of complete filter-based TCEP during TAVR warrants further research. © 2017 Wiley Periodicals, Inc.

  12. Analysis of the selected mechanical parameters of coating of filters protecting against hazardous infrared radiation.

    Science.gov (United States)

    Gralewicz, Grzegorz; Owczarek, Grzegorz; Kubrak, Janusz

    2017-03-01

    This article presents a comparison of the test results of selected mechanical parameters (hardness, Young's modulus, critical force for delamination) for protective filters intended for eye protection against harmful infrared radiation. Filters with reflective metallic films were studied, as well as interference filters developed at the Central Institute for Labour Protection - National Research Institute (CIOP-PIB). The test results of the selected mechanical parameters were compared with the test results, conducted in accordance with a standardised method, of simulating filter surface destruction that occurs during use.

  13. Analysis of the selected optical parameters of filters protecting against hazardous infrared radiation

    OpenAIRE

    Gralewicz, Grzegorz; Owczarek, Grzegorz

    2016-01-01

    The paper analyses the selected optical parameters of protective optic filters used for protection of the eyes against hazardous radiation within the visible (VIS) and near infrared (NIR) spectrum range. The indexes characterizing transmission and reflection of optic radiation incident on the filter are compared. As it follows from the completed analysis, the newly developed interference filters provide more effective blocking of infrared radiation in comparison with the currently used protec...

  14. Defining quality for distal pancreatectomy: does the laparoscopic approach protect patients from poor quality outcomes?

    Science.gov (United States)

    Baker, Marshall S; Sherman, Karen L; Stocker, Susan; Hayman, Amanda V; Bentrem, David J; Prinz, Richard A; Talamonti, Mark S

    2013-02-01

    Established systems for grading postoperative complications do not change the assigned grade when multiple interventions or readmissions are required to manage a complication. Studies using these systems may misrepresent outcomes for the surgical procedures being evaluated. We define a quality outcome for distal pancreatectomy (DP) and use this metric to compare laparoscopic distal pancreatectomy (LDP) to open distal pancreatectomy (ODP). Records for patients undergoing DP between January 2006 and December 2009 were reviewed. Clavien-Dindo grade IIIb, IV, and V complications were classified as severe adverse--poor quality--postoperative outcomes (SAPOs). II and IIIa complications requiring either significantly prolonged overall lengths of stay including readmissions within 90 days or more than one invasive intervention were also classified as SAPOs. By Clavien-Dindo system alone, 91 % of DP patients had either no complication or a low/moderate grade (I, II, IIIa) complication. Using our reclassification, however, 25 % had a SAPO. Patients undergoing LDP demonstrated a Clavien-Dindo complication profile identical to that for SDP but demonstrated significantly shorter overall lengths of stay, were less likely to require perioperative transfusion, and less likely to have a SAPO. Established systems undergrade the severity of some complications following DP. Using a procedure-specific metric for quality, we demonstrate that LDP affords a higher quality postoperative outcome than ODP.

  15. Combined application of distal and proximal embolic protection devices in endovascular stenting for severe carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Zhi-hua DU

    2011-09-01

    Full Text Available Objective To analyze and summarize methods and experiences of combined application of distal and proximal embolic protection devices(EPD in endovascular stenting for severe carotid artery stenosis.Methods Five patients with severe stenosis of the common carotid artery or with extracranial segment of the internal carotid artery diagnosed through digital subtraction angiography(DSA from March to July 2010 were involved in the present study.All patients received carotid angioplasty and stenting(CAS,with a combination of distal and proximal EPD via the percutaneous femoral artery approach.Results The operation failed in one patient,whereas technical success with no intraoperative complication was achieved in four patients.The symptoms disappeared or improved in the four cases that achieved technical success.The follow-up duration was one to three months,and no cerebral ischemia was found.Conclusion CAS with the combined application of distal and proximal EPD in some special cases of carotid artery stenosis may surmount the shortage of single EPD,reduce the risk of intraoperative embolization,decrease the time of intraoperative endovascular inflow occlusion,and reduce high-risk operations.CAS may be used as an individualized treatment strategy for patients with carotid artery stenosis.

  16. The Guenther temporary inferior vena cava filter for short-term protection against pulmonary embolism

    International Nuclear Information System (INIS)

    Vos, Louwerens D.; Tielbeek, Alexander V.; Bom, Ernst P.; Gooszen, Harm C.; Vroegindeweij, Dammis

    1997-01-01

    Purpose. To evaluate clinically the Guenther temporary inferior vena cava (IVC) filter. Methods. Eleven IVC filters were placed in 10 patients. Indications for filter placement were surgical pulmonary embolectomy in seven patients, pulmonary embolism in two patients, and free-floating iliofemoral thrombus in one patient. Eight filters were inserted from the right femoral approach, three filters from the left. Follow-up was by plain abdominal radiographs, cavography, and duplex ultrasound (US). Eight patients received systemic heparinization. Follow-up, during 4-60 months after filter removal was by clinical assessment, and imaging of the lungs was performed when pulmonary embolism (PE) was suspected. Patients received anticoagulation therapy for at least 6 months. Results. Ten filters were removed without complications 7-14 days (mean 10 days) after placement. One restless patient pulled the filter back into the common femoral vein, and a permanent filter was placed. In two patients a permanent filter was placed prior to removal. One patient developed sepsis, and one an infection at the insertion site. Clinically no recurrent PE developed with the filter in place or during removal. One patient had recurrent PE 7 months after filter removal. Conclusion. The Guenther temporary IVC filter can be safely placed for short-term protection against PE. The use of this filter is not appropriate in agitated or immunocompromised patients

  17. Distal and Proximal Religiosity as Protective Factors for Adolescent and Emerging Adult Alcohol Use

    Directory of Open Access Journals (Sweden)

    Michelle V. Porche

    2015-04-01

    Full Text Available Data from emerging adults (ages 18–29, N = 900 in the National Comorbidity Survey Replication Study was used to examine the influence of childhood and emerging adult religiosity and religious-based decision-making, and childhood adversity, on alcohol use. Childhood religiosity was protective against early alcohol use and progression to later abuse or dependence, but did not significantly offset the influence of childhood adversity on early patterns of heavy drinking in adjusted logistic regression models. Religiosity in emerging adulthood was negatively associated with alcohol use disorders. Protective associations for religiosity varied by gender, ethnicity and childhood adversity histories. Higher religiosity may be protective against early onset alcohol use and later development of alcohol problems, thus, should be considered in prevention programming for youth, particularly in faith-based settings. Mental health providers should allow for integration of clients’ religiosity and spirituality beliefs and practices in treatment settings if clients indicate such interest.

  18. Protected-area boundaries as filters of plant invasions.

    Science.gov (United States)

    Foxcroft, Llewellyn C; Jarošík, Vojtěch; Pyšek, Petr; Richardson, David M; Rouget, Mathieu

    2011-04-01

    Human land uses surrounding protected areas provide propagules for colonization of these areas by non-native species, and corridors between protected-area networks and drainage systems of rivers provide pathways for long-distance dispersal of non-native species. Nevertheless, the influence of protected-area boundaries on colonization of protected areas by invasive non-native species is unknown. We drew on a spatially explicit data set of more than 27,000 non-native plant presence records for South Africa's Kruger National Park to examine the role of boundaries in preventing colonization of protected areas by non-native species. The number of records of non-native invasive plants declined rapidly beyond 1500 m inside the park; thus, we believe that the park boundary limited the spread of non-native plants. The number of non-native invasive plants inside the park was a function of the amount of water runoff, density of major roads, and the presence of natural vegetation outside the park. Of the types of human-induced disturbance, only the density of major roads outside the protected area significantly increased the number of non-native plant records. Our findings suggest that the probability of incursion of invasive plants into protected areas can be quantified reliably. ©2010 Society for Conservation Biology.

  19. Randomized comparison of distal and proximal cerebral protection during carotid artery stenting.

    Science.gov (United States)

    Cano, Manuel N; Kambara, Antônio M; de Cano, Silvia J F; Pezzi Portela, Luiz Antônio; Paes, Ângela Tavares; Costa, J Ribamar; Abizaid, Alexandre Antônio Cunha; Moreira, Samuel Martins; Sousa, Amanda G M R; Sousa, J Eduardo Moraes Rego

    2013-11-01

    This study sought to randomly compare cerebral protection with ANGIOGUARD (Cordis Corporation, Bridgewater, New Jersey) with Mo.Ma (Invatec/Medtronic Vascular Inc, Santa Rosa, California) during carotid artery stenting (CAS), using diffusion-weighted magnetic resonance imaging (DW-MRI) to detect new ischemic cerebral lesions. The number, size, and location of lesions were analyzed. The choice of the type of cerebral protection during CAS is controversial. From July 2008 to July 2011, 60 patients undergoing CAS were randomized to ANGIOGUARD or Mo.Ma, distributed by chance, 30 patients for each group. All patients underwent DW-MRI before and after CAS. An independent neuroradiologist blinded to the cerebral protection used analyzed the images. Univariate and multivariate logistic models were fitted to analyze new ischemic lesions. Alternatively, a propensity score approach was used to reduce the bias due to differences between the groups. For the number of lesions, we used Poisson regression models. New ischemic lesions seen on DW-MRI were present in 63.3% of the ANGIOGUARD group versus 66.7% of the Mo.Ma cohort (p = 0.787). The number of ischemic cerebral lesions per patient, when present, was significantly lower in the Mo.Ma group (a median of 6 lesions per patient vs. a median of 10 in the ANGIOGUARD, p minor stroke during CAS (1.66%). New ischemic lesions seen on DW-MRI were present in both groups in >60%, but the number of lesions per patient was greater in the ANGIOGUARD group. No death or disabling stroke occurred during at least 1 year of follow-up in both cohorts. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Protected-area boundaries as filters of plant invasions

    Czech Academy of Sciences Publication Activity Database

    Foxcroft, L. C.; Jarošík, Vojtěch; Pyšek, Petr; Richardson, D. M.; Rouget, M.

    2010-01-01

    Roč. 25, č. 2 (2010), s. 400-405 ISSN 0888-8892 R&D Projects: GA MŠk LC06073; GA ČR GA206/09/0563 Grant - others: European Comission(XE) KBBE-212459 Institutional research plan: CEZ:AV0Z60050516 Keywords : protected areas * invasive plants * Kruger National Park Subject RIV: EF - Botanics Impact factor: 4.894, year: 2010

  1. DISTAL MYOPATHIES

    Science.gov (United States)

    Dimachkie, Mazen M.; Barohn, Richard J.

    2014-01-01

    Over a century ago, Gowers described two young patients in whom distal muscles weakness involved the hand, foot, sternocleidomastoid, and facial muscles in the other case the shoulder and distal leg musculature. Soon after, , similar distal myopathy cases were reported whereby the absence of sensory symptoms and of pathologic changes in the peripheral nerves and spinal cord at postmortem examination allowed differentiation from Charcot-Marie-Tooth disease. In 1951, Welander described autosomal dominant (AD) distal arm myopathy in a large Scandanavian cohort. Since then the number of well-characterized distal myopathies has continued to grow such that the distal myopathies have formed a clinically and genetically heterogeneous group of disorders. Affected kindred commonly manifest weakness that is limited to foot and toe muscles even in advanced stages of the disease, with variable mild proximal leg, distal arm, neck and laryngeal muscle involvement in selected individuals. An interesting consequence of the molecular characterization of the distal myopathies has been the recognition that mutation in a single gene can lead to more than one clinical disorder. For example, Myoshi myopathy (MM) and limb girdle muscular dystrophy (LGMD) type 2B are allelic disorders due to defects in the gene that encodes dysferlin. The six well described distal myopathy syndromes are shown in Table 1. Table 2 lists advances in our understanding of the myofibrillar myopathy group and Table 3 includes more recently delineated and less common distal myopathies. In the same manner, the first section of this review pertains to the more traditional six distal myopathies followed by discussion of the myofibrillar myopathies. In the third section, we review other clinically and genetically distinctive distal myopathy syndromes usually based upon single or smaller family cohorts. The fourth section considers other neuromuscular disorders that are important to recognize as they display prominent

  2. A Strategy toward Collaborative Filter Recommended Location Service for Privacy Protection.

    Science.gov (United States)

    Wang, Peng; Yang, Jing; Zhang, Jianpei

    2018-05-11

    A new collaborative filtered recommendation strategy was proposed for existing privacy and security issues in location services. In this strategy, every user establishes his/her own position profiles according to their daily position data, which is preprocessed using a density clustering method. Then, density prioritization was used to choose similar user groups as service request responders and the neighboring users in the chosen groups recommended appropriate location services using a collaborative filter recommendation algorithm. The two filter algorithms based on position profile similarity and position point similarity measures were designed in the recommendation, respectively. At the same time, the homomorphic encryption method was used to transfer location data for effective protection of privacy and security. A real location dataset was applied to test the proposed strategy and the results showed that the strategy provides better location service and protects users' privacy.

  3. A Strategy toward Collaborative Filter Recommended Location Service for Privacy Protection

    Science.gov (United States)

    Wang, Peng; Yang, Jing; Zhang, Jianpei

    2018-01-01

    A new collaborative filtered recommendation strategy was proposed for existing privacy and security issues in location services. In this strategy, every user establishes his/her own position profiles according to their daily position data, which is preprocessed using a density clustering method. Then, density prioritization was used to choose similar user groups as service request responders and the neighboring users in the chosen groups recommended appropriate location services using a collaborative filter recommendation algorithm. The two filter algorithms based on position profile similarity and position point similarity measures were designed in the recommendation, respectively. At the same time, the homomorphic encryption method was used to transfer location data for effective protection of privacy and security. A real location dataset was applied to test the proposed strategy and the results showed that the strategy provides better location service and protects users’ privacy. PMID:29751670

  4. A Strategy toward Collaborative Filter Recommended Location Service for Privacy Protection

    Directory of Open Access Journals (Sweden)

    Peng Wang

    2018-05-01

    Full Text Available A new collaborative filtered recommendation strategy was proposed for existing privacy and security issues in location services. In this strategy, every user establishes his/her own position profiles according to their daily position data, which is preprocessed using a density clustering method. Then, density prioritization was used to choose similar user groups as service request responders and the neighboring users in the chosen groups recommended appropriate location services using a collaborative filter recommendation algorithm. The two filter algorithms based on position profile similarity and position point similarity measures were designed in the recommendation, respectively. At the same time, the homomorphic encryption method was used to transfer location data for effective protection of privacy and security. A real location dataset was applied to test the proposed strategy and the results showed that the strategy provides better location service and protects users’ privacy.

  5. Development and stability studies of sunscreen cream formulations containing three photo-protective filters

    OpenAIRE

    Smaoui, Slim; Ben Hlima, Hajer; Ben Chobba, Ines; Kadri, Adel

    2013-01-01

    The present study aimed to formulate and subsequently evaluate sunscreen cream (W/O/W emulsion) containing three photo-protective filters: benzophenone-3, ethylhexyl methoxycinnamate and titanium dioxide at different percentages. Formulations were stored at 8, 25 and 40 °C for four weeks to investigate their stability. Color, centrifugation, liquefaction, phase separation, pH and Sun Protection Factor (SPF) of sunscreen cream formulations were determined. The microbiological stability of the ...

  6. 42 CFR 84.1151 - DOP filter test; respirators designed as respiratory protection against dusts, fumes, and mists...

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false DOP filter test; respirators designed as... filter test; respirators designed as respiratory protection against dusts, fumes, and mists having an air...) All single air-purifying respirator filter units will be tested in an atmosphere concentration of 100...

  7. Distal mdx muscle groups exhibiting up-regulation of utrophin and rescue of dystrophin-associated glycoproteins exemplify a protected phenotype in muscular dystrophy

    Science.gov (United States)

    Dowling, Paul; Culligan, Kevin; Ohlendieck, Kay

    2002-02-01

    Unique unaffected skeletal muscle fibres, unlike necrotic torso and limb muscles, may pave the way for a more detailed understanding of the molecular pathogenesis of inherited neuromuscular disorders and help to develop new treatment strategies for muscular dystrophies. The sparing of extraocular muscle in Duchenne muscular dystrophy is mostly attributed to the special protective properties of extremely fast-twitching small-diameter fibres, but here we show that distal muscles also represent a particular phenotype that is more resistant to necrosis. Immunoblot analysis of membranes isolated from the well established dystrophic animal model mdx shows that, in contrast to dystrophic limb muscles, the toe musculature exhibits an up-regulation of the autosomal dystrophin homologue utrophin and a concomitant rescue of dystrophin-associated glycoproteins. Thus distal mdx muscle groups provide a cellular system that naturally avoids myofibre degeneration which might be useful in the search for naturally occurring compensatory mechanisms in inherited skeletal muscle diseases.

  8. Protecting nickel with graphene spin-filtering membranes: A single layer is enough

    Energy Technology Data Exchange (ETDEWEB)

    Martin, M.-B.; Dlubak, B.; Piquemal-Banci, M.; Collin, S.; Petroff, F.; Anane, A.; Fert, A.; Seneor, P. [Unité Mixte de Physique CNRS/Thales, 1 Avenue Augustin Fresnel, 91767 Palaiseau, France and Université Paris Sud, 91405 Orsay (France); Weatherup, R. S.; Hofmann, S.; Robertson, J. [Department of Engineering, University of Cambridge, Cambridge CB21PZ (United Kingdom); Yang, H. [IBS Center for Integrated Nanostructure Physics (CINAP), Institute for Basic Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Department of Energy Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Blume, R. [Helmholtz-Zentrum Berlin fur Materialien und Energie, 12489 Berlin (Germany); Schloegl, R. [Department of Inorganic Chemistry, Fritz Haber Institute of the Max Planck Society, Faradayweg 4-6, 14195 Berlin (Germany)

    2015-07-06

    We report on the demonstration of ferromagnetic spin injectors for spintronics which are protected against oxidation through passivation by a single layer of graphene. The graphene monolayer is directly grown by catalytic chemical vapor deposition on pre-patterned nickel electrodes. X-ray photoelectron spectroscopy reveals that even with its monoatomic thickness, monolayer graphene still efficiently protects spin sources against oxidation in ambient air. The resulting single layer passivated electrodes are integrated into spin valves and demonstrated to act as spin polarizers. Strikingly, the atom-thick graphene layer is shown to be sufficient to induce a characteristic spin filtering effect evidenced through the sign reversal of the measured magnetoresistance.

  9. Effective endovascular treatment of calcified femoropopliteal disease with directional atherectomy and distal embolic protection: final results of the DEFINITIVE Ca⁺⁺ trial.

    Science.gov (United States)

    Roberts, David; Niazi, Khusrow; Miller, William; Krishnan, Prakash; Gammon, Roger; Schreiber, Theodore; Shammas, Nicolas W; Clair, Daniel

    2014-08-01

    The purpose of the DEFINITIVE Ca(++) study was to evaluate the safety and effectiveness of directional atherectomy and distal embolic protection, used together to treat moderate to severely calcified femoropopliteal lesions. Despite advances in endovascular treatment modalities, treatment of calcified lesions remains a challenge. A total of 133 subjects with 168 moderate to severely calcified lesions were enrolled. Lesions were treated with directional atherectomy devices, coupled with distal embolic protection. The 30-day freedom from MAE rate was 93.1%. Per angiographic core laboratory assessment, the primary effectiveness endpoint (≤50% residual diameter stenosis) was achieved in 92.0% (lower confidence bound of 87.6%) of lesions. By core lab analysis, these results did not achieve the success criteria (90%) for the primary effectiveness objective. Per site assessment, the objective was met with the endpoint being achieved in 97.0% (lower confidence bound 93.8%). A mean residual diameter stenosis of 33.3% was achieved with the directional atherectomy device. This was further decreased to 24.1% with the use of adjunctive therapy. The proportion of asymptomatic subjects [Rutherford Clinical Category (RCC) = 0] increased from 0% at baseline to 52.3% at the 30-day follow-up visit. In total, 88.5% of subjects experienced an improvement of one or more Rutherford categories. The results of the DEFINITIVE Ca++ study demonstrate that the SilverHawk and TurboHawk atherectomy devices are safe and effective in the endovascular treatment of moderate to severely calcified lesions in the superficial femoral and/or popliteal arteries when used with the SpiderFX distal embolic protection device. © 2014 The Authors. Catheterization and Cardiovascular Interventions. Published by Wiley Periodicals, Inc.

  10. Effective Endovascular Treatment of Calcified Femoropopliteal Disease With Directional Atherectomy and Distal Embolic Protection: Final Results of the DEFINITIVE Ca++ Trial

    Science.gov (United States)

    Roberts, David; Niazi, Khusrow; Miller, William; Krishnan, Prakash; Gammon, Roger; Schreiber, Theodore; Shammas, Nicolas W; Clair, Daniel

    2014-01-01

    Objectives The purpose of the DEFINITIVE Ca++ study was to evaluate the safety and effectiveness of directional atherectomy and distal embolic protection, used together to treat moderate to severely calcified femoropopliteal lesions. Background Despite advances in endovascular treatment modalities, treatment of calcified lesions remains a challenge. Methods A total of 133 subjects with 168 moderate to severely calcified lesions were enrolled. Lesions were treated with directional atherectomy devices, coupled with distal embolic protection. Results The 30-day freedom from MAE rate was 93.1%. Per angiographic core laboratory assessment, the primary effectiveness endpoint (≤50% residual diameter stenosis) was achieved in 92.0% (lower confidence bound of 87.6%) of lesions. By core lab analysis, these results did not achieve the success criteria (90%) for the primary effectiveness objective. Per site assessment, the objective was met with the endpoint being achieved in 97.0% (lower confidence bound 93.8%). A mean residual diameter stenosis of 33.3% was achieved with the directional atherectomy device. This was further decreased to 24.1% with the use of adjunctive therapy. The proportion of asymptomatic subjects [Rutherford Clinical Category (RCC) = 0] increased from 0% at baseline to 52.3% at the 30-day follow-up visit. In total, 88.5% of subjects experienced an improvement of one or more Rutherford categories. Conclusions The results of the DEFINITIVE Ca++ study demonstrate that the SilverHawk™ and TurboHawk™ atherectomy devices are safe and effective in the endovascular treatment of moderate to severely calcified lesions in the superficial femoral and/or popliteal arteries when used with the SpiderFX™ distal embolic protection device. © 2014 Wiley Periodicals, Inc. PMID:24402764

  11. Study of filterable materials and protection instruments by the use of radioactive aerosols

    International Nuclear Information System (INIS)

    Billard; Chevalier; Pradel

    1960-01-01

    Many filtration problems can be studied by means of radioactive aerosols. For the investigations described in this paper we have chosen the solid disintegration products of radon, the radioactive gas formed from radium, because of the facilities of generation and measurement it offers. Radon and its daughters are in fact always present in the atmosphere in sufficient concentration for certain tests. In order to improve the sensitivity of the measurements, radon from uranium ore can be used. The technique of measuring by counting α particles is rapid and easy to employ. We have thus been able to define a test for filterable substances, and to check filtering installation and individual protection instruments. (author) [fr

  12. A DSP-Based Beam Current Monitoring System for Machine Protection Using Adaptive Filtering

    International Nuclear Information System (INIS)

    J. Musson; H. Dong; R. Flood; C. Hovater; J. Hereford

    2001-01-01

    The CEBAF accelerator at Jefferson Lab is currently using an analog beam current monitoring (BCM) system for its machine protection system (MPS), which has a loss accuracy of 2 micro-amps. Recent burn-through simulations predict catastrophic beam line component failures below 1 micro-amp of loss, resulting in a blind spot for the MPS. Revised MPS requirements target an ultimate beam loss accuracy of 250 nA. A new beam current monitoring system has been developed which utilizes modern digital receiver technology and digital signal processing concepts. The receiver employs a direct-digital down converter integrated circuit, mated with a Jefferson Lab digital signal processor VME card. Adaptive filtering is used to take advantage of current-dependent burn-through rates. Benefits of such a system include elimination of DC offsets, generic algorithm development, extensive filter options, and interfaces to UNIX-based control systems

  13. Cerebral ischemia after filter-protected carotid artery stenting is common and cannot be predicted by the presence of substantial amount of debris captured by the filter device.

    Science.gov (United States)

    Maleux, G; Demaerel, P; Verbeken, E; Daenens, K; Heye, S; Van Sonhoven, F; Nevelsteen, A; Wilms, G

    2006-10-01

    Protected carotid artery stent placement is currently under clinical evaluation as a potential alternative to carotid endarterectomy. The current study was undertaken to determine the incidence of new ischemic lesions found on diffusion-weighted MR imaging (DWI) in nonselected patients after protected carotid artery stent placement using a filter device and to determine the potential relationship between these new ischemic lesions and the presence or absence of a clear amount of debris captured by the neuroprotection filter device. A nonrandomized cohort of 52 patients (40 men, 12 women) presenting with carotid occlusive disease underwent protected carotid artery stent placement using a filter device. DWI obtained 1 day before stent placement was compared with that obtained 1 day after stent placement. In addition, the macroscopic and microscopic analysis of debris captured by the filter device during the carotid stent placement procedure was assessed. Neuroprotected carotid stent placement was technically successful in all 53 procedures but was complicated by a transient ischemic attack in 3 patients (5.6%). In 22 patients (41.5%), new ischemic lesions were found on DWI, and in 21 filter devices (39.6%), a substantial amount of atheromatous plaque and/or fibrin was found. No clear relationship between the presence of debris captured by the filter device and new lesions detected by DWI was found (P = .087; odds ratio 3.067). Neuroprotected carotid artery stent placement will not avoid silent cerebral ischemia. Systematic microscopic analysis of debris captured by the filter device has no predictive value for potential cerebral ischemia after carotid artery stent placement.

  14. Short wavelengths filtering properties of sunglasses on the Canadian market: are we protected?

    Science.gov (United States)

    Trang, Nataly; Lalonde, Gilles; Dubé, Yolande; Bourgault, Serge; Rochette, Patrick J

    2018-04-01

    Exposure to solar radiation is a risk factor for multiple ocular pathologies. Ultraviolet (UV) radiation is involved in ocular diseases, including pterygium, ocular surface squamous neoplasia, and cataracts. High-energy visible light (HEV) is associated with age-related macular degeneration. Ocular protection against solar radiation seems essential to protect our eyes against the adverse effects of those harmful rays. Australia, New Zealand, Europe, and the United States are the only regions with mandatory standards for UV transmission for sunglasses. Adherence to Canadian standards by sunglasses manufacturers is not mandatory. In this study, we evaluated the UV and visible transmission of sunglasses in the Canadian market to test their compliance with Canadian standards. The transmittance of 207 pairs of sunglasses, divided in 3 categories according to their price range, was measured. We show that close to 100% of the sunglasses tested respect the Canadian standards. The average HEV transmittance is around 10%, regardless the price range. Our study demonstrated that even if following Canadian standards is optional, most sunglasses sold on the Canadian market follow national and international standards. We also found that sunglasses filter around 90% of HEV. With the recent findings on the potential effects of HEV in retinal pathologies, we can ask whether this filtering capacity is sufficient to protect eyes from harmful HEV light. More work needs to be done to determine acceptable HEV light transmission limits to the existing Canadian standards. Copyright © 2018 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  15. UV protection filters by dielectric multilayer thin films on Glass BK-7 and Infrasil 301

    International Nuclear Information System (INIS)

    Abdel-Aziz, M.M.; Azim, Osama A.; Abdel-Wahab, L.A.; Seddik, Mohamed M.

    2006-01-01

    The increasing use of Ultraviolet (UV) light in medicine, industrial environments, for cosmetic use, and even in consumer products necessitates that greater attention be paid to the potential hazards of this type of electromagnetic radiation. To avoid any adverse effects of exposure to this type of radiation, four suitable protection filters were produced to block three UV bands (UVA, UVB, and UVC). The design structure of the required dielectric multilayer filters was done by optical thin film technology using the absorbing property of UV radiation for the substrates and dielectric materials. The computer analyses of the multilayer filter formulas were prepared using Macleod Software for the production processes. The deposition technique was achieved on optical substrates (Glass BK-7 and Infrasil 301) by dielectric material combinations including Titanium dioxide (Ti 2 O 3 ), Hafnium dioxide (HfO 2 ), and Lima (mixture of oxides SiO 2 /Al 2 O 3 ); deposition being achieved using an electron beam gun. The output results of the theoretical and experimental transmittance values for spectral band from 200 nm to 800 nm were discussed in four processes. To analyze the suitability for use in 'real world' applications, the test pieces were subjected to the durability tests (adhesion, abrasion resistance, and humidity) according to Military Standard MIL-C-675C and MIL-C-48497A

  16. UV protection filters by dielectric multilayer thin films on Glass BK-7 and Infrasil 301

    Science.gov (United States)

    Abdel-Aziz, M. M.; Azim, Osama A.; Abdel-Wahab, L. A.; Seddik, Mohamed M.

    2006-10-01

    The increasing use of Ultraviolet (UV) light in medicine, industrial environments, for cosmetic use, and even in consumer products necessitates that greater attention be paid to the potential hazards of this type of electromagnetic radiation. To avoid any adverse effects of exposure to this type of radiation, four suitable protection filters were produced to block three UV bands (UVA, UVB, and UVC). The design structure of the required dielectric multilayer filters was done by optical thin film technology using the absorbing property of UV radiation for the substrates and dielectric materials. The computer analyses of the multilayer filter formulas were prepared using Macleod Software for the production processes. The deposition technique was achieved on optical substrates (Glass BK-7 and Infrasil 301) by dielectric material combinations including Titanium dioxide (Ti 2O 3), Hafnium dioxide (HfO 2), and Lima (mixture of oxides SiO 2/Al 2O 3); deposition being achieved using an electron beam gun. The output results of the theoretical and experimental transmittance values for spectral band from 200 nm to 800 nm were discussed in four processes. To analyze the suitability for use in 'real world' applications, the test pieces were subjected to the durability tests (adhesion, abrasion resistance, and humidity) according to Military Standard MIL-C-675C and MIL-C-48497A.

  17. Test equipment used for radiation protection type testing of aerosol filters at the National Board of Nuclear Safety and Radiation Protection (SAAS)

    International Nuclear Information System (INIS)

    Ullmann, W.; Przyborowski, S.

    1977-01-01

    Following a description of the overall design of test equipment developed in the SAAS for radiation protection type testing of aerosol filters, the most important physical and technical details concerning the preparation and measurement of test aerosols as well as the sampling procedure upstream and downstream of the filter to the tested, are comprehensively discussed. Furthermore, experiences gained during several years with different devices for mixing and diluting the aerosols are reported. (author)

  18. Sunglass Filter Transmission and Its Operational Effect in Solar Protection for Civilian Pilots.

    Science.gov (United States)

    Chorley, Adrian C; Lyachev, Andrey; Higlett, Michael P; Khazova, Marina; Benwell, Martin J; Evans, Bruce J W

    2016-05-01

    The ocular effects of excess solar radiation exposure are well documented. Recent evidence suggests that ocular ultraviolet radiation (UVR) exposure to professional pilots may fall outside international guideline limits unless eye protection is used. Nonprescription sunglasses should be manufactured to meet either international or national standards. The mean increase in UVR and blue light hazards at altitude has been quantified and the aim of this research was to assess the effectiveness of typical pilot sunglasses in reducing UVR and blue light hazard exposure in flight. A series of sunglass filter transmittance measurements were taken from personal sunglasses (N = 20) used by pilots together with a series of new sunglasses (N = 18). All nonprescription sunglasses measured conformed to international standards for UVR transmittance and offered sufficient UVR protection for pilots. There was no difference between right and left lenses or between new and used sunglasses. All sunglasses offered sufficient attenuation to counter the mean increase in blue light exposure that pilots experience at altitude, although used sunglasses with scratched lenses were marginally less effective. One pair of prescription sunglasses offered insufficient UVR attenuation for some flights, but would have met requirements of international and national standards for UV-A transmittance. This was likely due to insufficient UVR blocking properties of the lens material. Lenses manufactured to minimally comply with standards for UVR transmittance could result in excess UVR exposure to a pilot based on in-flight irradiance data; an additional requirement of less than 10% transmittance at 380 nm is recommended.

  19. Development and stability studies of sunscreen cream formulations containing three photo-protective filters

    Directory of Open Access Journals (Sweden)

    Slim Smaoui

    2017-02-01

    Full Text Available The present study aimed to formulate and subsequently evaluate sunscreen cream (W/O/W emulsion containing three photo-protective filters: benzophenone-3, ethylhexyl methoxycinnamate and titanium dioxide at different percentages. Formulations were stored at 8, 25 and 40 °C for four weeks to investigate their stability. Color, centrifugation, liquefaction, phase separation, pH and Sun Protection Factor (SPF of sunscreen cream formulations were determined. The microbiological stability of the creams was also evaluated and the organoleptic quality was carried out for 28 days. Interestingly, the combination of 7% Benzophenone-3, 7% Ethylhexyl methoxycinnamate and 6% Titanium dioxide preserved physicochemical properties of the product and was efficient against the development of different spoilage microorganisms as well as aerobic plate counts, Pseudomonas aeruginosa, Staphylococcus aureus, and yeast and mold counts. Furthermore, a good stability was observed for all formulations throughout the experimental period. The newly formulated sunscreen cream was proved to exhibit a number of promising properties and attributes that might open new opportunities for the development of more efficient, safe, and cost-effective skin-care, cosmetic, and pharmaceutical products.

  20. Self-limiting filters for band-selective interferer rejection or cognitive receiver protection

    Science.gov (United States)

    Nordquist, Christopher; Scott, Sean Michael; Custer, Joyce Olsen; Leonhardt, Darin; Jordan, Tyler Scott; Rodenbeck, Christopher T.; Clem, Paul G.; Hunker, Jeff; Wolfley, Steven L.

    2017-03-07

    The present invention related to self-limiting filters, arrays of such filters, and methods thereof. In particular embodiments, the filters include a metal transition film (e.g., a VO.sub.2 film) capable of undergoing a phase transition that modifies the film's resistivity. Arrays of such filters could allow for band-selective interferer rejection, while permitting transmission of non-interferer signals.

  1. Self-limiting filters for band-selective interferer rejection or cognitive receiver protection

    Energy Technology Data Exchange (ETDEWEB)

    Nordquist, Christopher; Scott, Sean Michael; Custer, Joyce Olsen; Leonhardt, Darin; Jordan, Tyler Scott; Rodenbeck, Christopher T.; Clem, Paul G.; Hunker, Jeff; Wolfley, Steven L.

    2017-03-07

    The present invention related to self-limiting filters, arrays of such filters, and methods thereof. In particular embodiments, the filters include a metal transition film (e.g., a VO.sub.2 film) capable of undergoing a phase transition that modifies the film's resistivity. Arrays of such filters could allow for band-selective interferer rejection, while permitting transmission of non-interferer signals.

  2. Shielding and filtering techniques to protect sensitive instrumentation from electromagnetic interference caused by arc welding

    International Nuclear Information System (INIS)

    Kalechstein, W.

    1997-01-01

    Electromagnetic interference (EMI) caused by arc welding is a concern for sensitive CANDU instrumentation and control equipment, especially start-up instrumentation (SUI) and ion chamber instruments used to measure neutron flux at low power. Measurements of the effectiveness of simple shielding and filtering techniques that may be applied to limit arc welding electromagnetic emissions below the interference threshold are described. Shielding configurations investigated include an arrangement in which the welding power supply, torch (electrode holder), interconnecting cables and welder operator were housed in a single enclosure and a more practical configuration of separate shields for the power supply, cables and operator with torch. The two configuration were found to provide 30 dB and 26 dB attenuation, respectively, for arc welder electric-field emissions and were successful in preventing EMI in SUI set up just outside the shielding enclosures. Practical improvements that may be incorporated in the shielding arrangement to facilitate quick setup in the field in a variety of application environments, while maintaining adequate EMI protection, are discussed. (author)

  3. Embolic Protection using the WIRION Embolic Protection System with JetStream Atherectomy in a Patient with Superficial Femoral Artery Chronic total Occlusion.

    Science.gov (United States)

    Shammas, Nicolas W

    2017-06-01

    Distal embolization is a common occurrence with peripheral arterial interventions and is more frequent with the use of atherectomy devices. We report the first case of JetStream atherectomy (Boston Scientific, Maple Grove, MN) with the use of the novel WIRION embolic protection system filter. The procedure was performed successfully with no distal embolizations beyond the filter and with no complications in the delivery or retrieval of the filter. The pros and cons of the off label use of this filter with JetStream atherectomy are discussed.

  4. Evaluation of the Survivability of Microorganisms Deposited on Filtering Respiratory Protective Devices under Varying Conditions of Humidity

    Directory of Open Access Journals (Sweden)

    Katarzyna Majchrzycka

    2016-01-01

    Full Text Available Bioaerosols are common biological factors in work environments, which require routine use of filtering respiratory protective devices (FRPDs. Currently, no studies link humidity changes in the filter materials of such devices, during use, with microorganism survivability. Our aim was to determine the microclimate inside FRPDs, by simulating breathing, and to evaluate microorganism survivability under varying humidity conditions. Breathing was simulated using commercial filtering facepiece respirators in a model system. Polypropylene melt-blown nonwoven fabrics with moisture contents of 40%, 80%, and 200%, were used for assessment of microorganisms survivability. A modified AATCC 100-2004 method was used to measure the survivability of ATCC and NCAIM microorganisms: Escherichia coli, Staphylococcus aureus, Bacillus subtilis, Candida albicans and Aspergillus niger. During simulation relative humidity under the facepiece increased after 7 min of usage to 84%–92% and temperature increased to 29–30 °C. S. aureus survived the best on filter materials with 40%–200% moisture content. A decrease in survivability was observed for E. coli and C. albicans when mass humidity decreased. We found that B. subtilis and A. niger proliferated for 48–72 h of incubation and then died regardless of the moisture content. In conclusion, our tests showed that the survivability of microorganisms on filter materials depends on the amount of accumulated moisture and microorganism type.

  5. Evaluation of the Survivability of Microorganisms Deposited on Filtering Respiratory Protective Devices under Varying Conditions of Humidity.

    Science.gov (United States)

    Majchrzycka, Katarzyna; Okrasa, Małgorzata; Skóra, Justyna; Gutarowska, Beata

    2016-01-04

    Bioaerosols are common biological factors in work environments, which require routine use of filtering respiratory protective devices (FRPDs). Currently, no studies link humidity changes in the filter materials of such devices, during use, with microorganism survivability. Our aim was to determine the microclimate inside FRPDs, by simulating breathing, and to evaluate microorganism survivability under varying humidity conditions. Breathing was simulated using commercial filtering facepiece respirators in a model system. Polypropylene melt-blown nonwoven fabrics with moisture contents of 40%, 80%, and 200%, were used for assessment of microorganisms survivability. A modified AATCC 100-2004 method was used to measure the survivability of ATCC and NCAIM microorganisms: Escherichia coli, Staphylococcus aureus, Bacillus subtilis, Candida albicans and Aspergillus niger. During simulation relative humidity under the facepiece increased after 7 min of usage to 84%-92% and temperature increased to 29-30 °C. S. aureus survived the best on filter materials with 40%-200% moisture content. A decrease in survivability was observed for E. coli and C. albicans when mass humidity decreased. We found that B. subtilis and A. niger proliferated for 48-72 h of incubation and then died regardless of the moisture content. In conclusion, our tests showed that the survivability of microorganisms on filter materials depends on the amount of accumulated moisture and microorganism type.

  6. Two-dimensional modelling of internal arc effects in an enclosed MV cell provided with a protection porous filter

    International Nuclear Information System (INIS)

    Rochette, D; Clain, S; Andre, P; Bussiere, W; Gentils, F

    2007-01-01

    Medium voltage (MV) cells have to respect standards (for example IEC ones (IEC TC 17C 2003 IEC 62271-200 High Voltage Switchgear and Controlgear-Part 200 1st edn)) that define security levels against internal arc faults such as an accidental electrical arc occurring in the apparatus. New protection filters based on porous materials are developed to provide better energy absorption properties and a higher protection level for people. To study the filter behaviour during a major electrical accident, a two-dimensional model is proposed. The main point is the use of a dedicated numerical scheme for a non-conservative hyperbolic problem. We present a numerical simulation of the process during the first 0.2 s when the safety valve bursts and we compare the numerical results with tests carried out in a high power test laboratory on real electrical apparatus

  7. Two-dimensional modelling of internal arc effects in an enclosed MV cell provided with a protection porous filter

    Science.gov (United States)

    Rochette, D.; Clain, S.; André, P.; Bussière, W.; Gentils, F.

    2007-05-01

    Medium voltage (MV) cells have to respect standards (for example IEC ones (IEC TC 17C 2003 IEC 62271-200 High Voltage Switchgear and Controlgear—Part 200 1st edn)) that define security levels against internal arc faults such as an accidental electrical arc occurring in the apparatus. New protection filters based on porous materials are developed to provide better energy absorption properties and a higher protection level for people. To study the filter behaviour during a major electrical accident, a two-dimensional model is proposed. The main point is the use of a dedicated numerical scheme for a non-conservative hyperbolic problem. We present a numerical simulation of the process during the first 0.2 s when the safety valve bursts and we compare the numerical results with tests carried out in a high power test laboratory on real electrical apparatus.

  8. Two-dimensional modelling of internal arc effects in an enclosed MV cell provided with a protection porous filter

    Energy Technology Data Exchange (ETDEWEB)

    Rochette, D [Laboratoire Arc Electrique et Plasmas Thermiques, CNRS UMR 6069, Universite Blaise Pascal, IUT de Montlucon, Avenue Aristide Briand, BP 2235, 03101 Montlucon Cedex (France); Clain, S [Laboratoire de Mathematiques pour l' Industrie et la Physique, CNRS UMR 5640, Universite Paul Sabatier Toulouse 3, 118 route de Narbonne, 31062 Toulouse Cedex 4 (France); Andre, P [Laboratoire Arc Electrique et Plasmas Thermiques, CNRS UMR 6069, Universite Blaise Pascal, IUT de Montlucon, Avenue Aristide Briand, BP 2235, 03101 Montlucon Cedex (France); Bussiere, W [Laboratoire Arc Electrique et Plasmas Thermiques, CNRS UMR 6069, Universite Blaise Pascal, IUT de Montlucon, Avenue Aristide Briand, BP 2235, 03101 Montlucon Cedex (France); Gentils, F [Schneider Electric-Science and Technology Division-Research Center A2, 38050 Grenoble Cedex 9 (France)

    2007-05-21

    Medium voltage (MV) cells have to respect standards (for example IEC ones (IEC TC 17C 2003 IEC 62271-200 High Voltage Switchgear and Controlgear-Part 200 1st edn)) that define security levels against internal arc faults such as an accidental electrical arc occurring in the apparatus. New protection filters based on porous materials are developed to provide better energy absorption properties and a higher protection level for people. To study the filter behaviour during a major electrical accident, a two-dimensional model is proposed. The main point is the use of a dedicated numerical scheme for a non-conservative hyperbolic problem. We present a numerical simulation of the process during the first 0.2 s when the safety valve bursts and we compare the numerical results with tests carried out in a high power test laboratory on real electrical apparatus.

  9. Internet filters and entry pages do not protect children from online alcohol marketing.

    Science.gov (United States)

    Jones, Sandra C; Thom, Jeffrey A; Davoren, Sondra; Barrie, Lance

    2014-02-01

    We review programs and policies to prevent children from accessing alcohol marketing online. To update the literature, we present our recent studies that assess (i) in-built barriers to underage access to alcohol brand websites and (ii) commercial internet filters. Alcohol websites typically had poor filter systems for preventing entry of underage persons; only half of the sites required the user to provide a date of birth, and none had any means of preventing users from trying again. Even the most effective commercial internet filters allowed access to one-third of the sites we examined.

  10. Mechanical ventilators in the hot zone: effects of a CBRN filter on patient protection and battery life.

    Science.gov (United States)

    Blakeman, Thomas C; Toth, Peter; Rodriquez, Dario; Branson, Richard D

    2010-09-01

    In a contaminated environment, respiratory protection for ventilator dependent patients can be achieved by attaching a chemical, biological, radiological, or nuclear (CBRN) filter to the air intake port of a portable ventilator. We evaluated the effect of the filter on battery performance of four portable ventilators in a laboratory setting. Each ventilator was attached to a test lung. Ventilator settings were: assist control (AC) mode, respiratory rate 35 bpm, tidal volume 450 ml, positive end-expiratory pressure (PEEP) 10 cm H(2)O, inspiratory time 0.8 s, and FIO(2) 0.21. Ventilators were operated until the battery was fully discharged. We also evaluated the ventilators' ability to deliver all the gas through the CBRN filter and analyzed the pressures required to breathe through the anti-asphyxiation valve of a failed device. The range of battery life varied widely across different ventilator models (99.8-562.6 min). There was no significant difference in battery life (pventilator dependent patients when environmental contamination is present, although conditions exist where all gas does not pass through the filter with some ventilators under normal operating conditions. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  11. Reverse Distal Transverse Palmar Arch in Distal Digital Replantation.

    Science.gov (United States)

    Wei, Ching-Yueh; Orozco, Oscar; Vinagre, Gustavo; Shafarenko, Mark

    2017-11-01

    Refinements in microsurgery have made distal finger replantation an established technique with high success rates and good functional and aesthetic outcomes. However, it still represents a technically demanding procedure due to the small vessel caliber and frequent lack of vessel length, requiring the use of interpositional venous grafts in some instances. We describe a new technique for anastomosis in fingertip replantation, whereby the need for venous grafts is eliminated. Applying the reverse distal transverse palmar arch technique, 11 cases of distal digital replantation were performed between January 2011 and July 2016. The described procedure was used for arterial anastomosis in 10 cases and arteriovenous shunting for venous drainage in 1 case. A retrospective case review was conducted. The technical description and clinical outcome evaluations are presented. Ten of the 11 replanted digits survived, corresponding to an overall success rate of 91%. One replant failed due to venous insufficiency. Blood transfusions were not required for any of the patients. Follow-up (range, 1.5-5 months) revealed near-normal range of motion and good aesthetic results. All of the replanted digits developed protective sensation. The average length of hospital admission was 5 days. All patients were satisfied with the results and were able to return to their previous work. The use of the reverse distal transverse palmar arch is a novel and reliable technique in distal digital replantation when an increase in vessel length is required, allowing for a tension-free arterial repair without the need for vein grafts.

  12. The protective role of ceramic filters against natural radioactivity of water

    International Nuclear Information System (INIS)

    Domanski, T.; Bakir, Y.Y.Y.; El-Zenki, S.; Bem, H.

    1992-01-01

    The paper presents results of measurements of the natural radioactivity of tap water where samples were taken in front of, and behind the ceramic filter commonly used in houses for the purification of tap water. Altogether, 289 samples were taken, processed and measured during 1985-1986 in Kuwait. Results reveal the fact that ceramic filters reduce substantially the natural radioactivity in water (the 'gross' alpha activity reduced by the factor 2.18 ± 18%; the 'gross' beta by 1.53 ± 1.6%. (author)

  13. Distal renal tubular acidosis

    Science.gov (United States)

    ... this disorder. Alternative Names Renal tubular acidosis - distal; Renal tubular acidosis type I; Type I RTA; RTA - distal; Classical RTA Images Kidney anatomy Kidney - blood and urine flow References Bose A, Monk RD, Bushinsky DA. Kidney ...

  14. Bacteriological Profile of Patients Undergoing Open Heart Surgery and Evaluation of a Bacterial Filter using Protected Broncho-Alveolar Lavage.

    Science.gov (United States)

    Tempe, D K; Mehta, N; Mishra, B; Tondon, M S; Tomar, A S; Budharaja, P; Nigam, M

    1998-01-01

    Twenty seven patients undergoing elective open heart surgery were included in this prospective study. They were randomly divided into two groups. Group C (n = 12) constituted the control group in whom no breathing filter was used in the anaesthesia circuit in the operating room or in the ICU. Humidification of breathing gases was achieved with the help of conventional heated humidifier. In group F (n = 15), heat and moisture exahanging bacterial / viral filter was incorporated in the breathing circuit at the patient end between the catheter mount and Y connection of the breathing circuit. In both the groups, samples of throat swab, protected broncho-alveolar lavage with double catheter and Ryles tube aspirate were collected preoperatively (in the operation theatre) and postoperatively (in the Intensive Care Unit on day 1). All the samples were sent to the laboratory immediately after the collection for Gram staining and culture and sensitivity. Pathogenic organisms were isolated from a total of 9 patients (33%) preoperatively. Exogenous spread of the organisms to the lungs was considered to have occurred if new pathogenic organisms were isolated from the postoperative bronchoalveolar lavage and the simultaneous samples of the throat swab and Ryles tube did not contain the same organism. By this definition, the exogenous spread of the organisms occurred in one patient in group C and in no patient in group F (P = 0.46, Fishers test). The commonest organisms isolated were Staphylococcus aureus, Klebsiella sp. and Pseudomonas sp. We conclude that colonization of the pathogenic organisms is common (33%) in orophrynx and gastrointestinal tract in hospitalized patients. There was no difference in the exogenous spread of the organisms between the two groups. The unity of the filter, therefore, appears to be limited to prevent contamination of anaesthesia machines or ventilators as has been shown by earlier studies.

  15. Sensory Pollution from Bag Filters, Carbon Filters and Combinations

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Clausen, Geo; Weschler, Charles J.

    2008-01-01

    by an upstream pre-filter (changed monthly), an EU7 filter protected by an upstream activated carbon (AC) filter, and EU7 filters with an AC filter either downstream or both upstream and downstream. In addition, two types of stand-alone combination filters were evaluated: a bag-type fiberglass filter...... that contained AC and a synthetic fiber cartridge filter that contained AC. Air that had passed through used filters was most acceptable for those sets in which an AC filter was used downstream of the particle filter. Comparable air quality was achieved with the stand-alone bag filter that contained AC...

  16. Distal digital replantation.

    Science.gov (United States)

    Jazayeri, Leila; Klausner, Jill Q; Chang, James

    2013-11-01

    Hand surgeons have been hesitant to perform distal digital replantation because of the technical challenges and the perception of a high cost-to-benefit ratio. Recent studies, however, have shown high survival rates and excellent functional and aesthetic results, providing renewed enthusiasm for distal replantation. The authors reviewed the literature and summarize key points regarding the surgical treatment, perioperative care, and outcomes of distal digital replantation. They describe specific techniques and considerations for surgical repair in each of four distal zones as described by Sebastin and Chung. Zone 1A replantation involves an artery-only anastomosis of a longitudinal pulp artery. Venous anastomosis first becomes possible in zone 1B. Zone 1C involves periarticular amputations where arthrodesis of the distal interphalangeal joint is usually indicated. Repair of the artery, vein, and nerve is technically optimal in zone 1D, where venous anastomosis should be performed. Overall, survival rates for distal digital replantation are similar to those reported for more proximal replantation. The literature reports good outcomes regarding nail salvage, fingertip sensibility, and range of motion, with restoration of length and aesthetic appearance. Distal replantation performed at institutions that specialize in microsurgery and specifically tailored to the level of injury is associated with good survival, function, and patient satisfaction and superior aesthetic outcome. More prospective data are needed to evaluate the cost of treatment, psychological outcomes, and functional outcomes of distal replantation compared with revision amputation.

  17. Digital filtering techniques applied to electric power systems protection; Tecnicas de filtragem digital aplicadas a protecao de sistemas eletricos de potencia

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Helio Glauco Ferreira

    1996-12-31

    This work introduces an analysis and a comparative study of some of the techniques for digital filtering of the voltage and current waveforms from faulted transmission lines. This study is of fundamental importance for the development of algorithms applied to digital protection of electric power systems. The techniques studied are based on the Discrete Fourier Transform theory, the Walsh functions and the Kalman filter theory. Two aspects were emphasized in this study: Firstly, the non-recursive techniques were analysed with the implementation of filters based on Fourier theory and the Walsh functions. Secondly, recursive techniques were analyzed, with the implementation of the filters based on the Kalman theory and once more on the Fourier theory. (author) 56 refs., 25 figs., 16 tabs.

  18. Interface control of atomic layer deposited oxide coatings by filtered cathodic arc deposited sublayers for improved corrosion protection

    Energy Technology Data Exchange (ETDEWEB)

    Härkönen, Emma, E-mail: emma.harkonen@helsinki.fi [Laboratory of Inorganic Chemistry, University of Helsinki, P.O. Box 55, FIN-00014 Helsinki (Finland); Tervakangas, Sanna; Kolehmainen, Jukka [DIARC-Technology Inc., Espoo (Finland); Díaz, Belén; Światowska, Jolanta; Maurice, Vincent; Seyeux, Antoine; Marcus, Philippe [Laboratoire de Physico-Chimie des Surfaces, CNRS (UMR 7075) – Chimie ParisTech (ENSCP), F-75005 Paris (France); Fenker, Martin [FEM Research Institute, Precious Metals and Metals Chemistry, D-73525 Schwäbisch Gmünd (Germany); Tóth, Lajos; Radnóczi, György [Research Centre for Natural Sciences HAS, (MTA TKK), Budapest (Hungary); Ritala, Mikko [Laboratory of Inorganic Chemistry, University of Helsinki, P.O. Box 55, FIN-00014 Helsinki (Finland)

    2014-10-15

    Sublayers grown with filtered cathodic arc deposition (FCAD) were added under atomic layer deposited (ALD) oxide coatings for interface control and improved corrosion protection of low alloy steel. The FCAD sublayer was either Ta:O or Cr:O–Ta:O nanolaminate, and the ALD layer was Al{sub 2}O{sub 3}–Ta{sub 2}O{sub 5} nanolaminate, Al{sub x}Ta{sub y}O{sub z} mixture or graded mixture. The total thicknesses of the FCAD/ALD duplex coatings were between 65 and 120 nm. Thorough analysis of the coatings was conducted to gain insight into the influence of the FCAD sublayer on the overall coating performance. Similar characteristics as with single FCAD and ALD coatings on steel were found in the morphology and composition of the duplex coatings. However, the FCAD process allowed better control of the interface with the steel by reducing the native oxide and preventing its regrowth during the initial stages of the ALD process. Residual hydrocarbon impurities were buried in the interface between the FCAD layer and steel. This enabled growth of ALD layers with improved electrochemical sealing properties, inhibiting the development of localized corrosion by pitting during immersion in acidic NaCl and enhancing durability in neutral salt spray testing. - Highlights: • Corrosion protection properties of ALD coatings were improved by FCAD sublayers. • The FCAD sublayer enabled control of the coating-substrate interface. • The duplex coatings offered improved sealing properties and durability in NSS. • The protective properties were maintained during immersion in a corrosive solution. • The improvements were due to a more ideal ALD growth on the homogeneous FCAD oxide.

  19. FiberNet--a new embolic protection device for carotid artery stenting.

    Science.gov (United States)

    Bauer, C; Franke, J; Bertog, S C; Woerner, V; Ghasemzadeh-Asl, S; Sievert, H

    2014-05-01

    Though distal filter protection during carotid stenting reduces the risk of cerebrovascular events, periprocedural stroke remains a risk despite their broad usage. This observation may be related to the pore size of common filters. The FiberNet distal filter system is unique by its very small pore size (40 µm) as well as its low profile and flexibility. Little data is available regarding the clinical performance and safety of this device. The aim was the evaluation of the safety of the FiberNet embolic protection system during carotid artery stenting. All consecutive patients treated with carotid stenting at our institution using the FiberNet device were systematically followed. Primary endpoint was the rate of all death and stroke within 30 days of the procedure. Carotid artery stenting using the FiberNet embolic protection system was performed in 54 patients. The procedure was technical successful in all patients. Three patients (5.5%) had a TIA. Amauosis fugax occurred in two patients (3.7%). One patient (1.9%) had a minor stroke with hemiparesis of the left arm and face which resolved completely within 48 hr after the procedure. No patient died or suffered a major stroke. The safety and feasibility of the FiberNet distal protection system appears to be at least equivalent to that reported in studies using conventional distal filter protection. Copyright © 2013 Wiley Periodicals, Inc.

  20. [Distal clavicle fracture].

    Science.gov (United States)

    Seppel, G; Lenich, A; Imhoff, A B

    2014-06-01

    Reposition and fixation of unstable distal clavicle fractures with a low profile locking plate (Acumed, Hempshire, UK) in conjunction with a button/suture augmentation cerclage (DogBone/FibreTape, Arthrex, Naples, FL, USA). Unstable fractures of the distal clavicle (Jäger and Breitner IIA) in adults. Unstable fractures of the distal clavicle (Jäger and Breitner IV) in children. Distal clavicle fractures (Jäger and Breitner I, IIB or III) with marked dislocation, injury of nerves and vessels, or high functional demand. Patients in poor general condition. Fractures of the distal clavicle (Jäger and Breitner I, IIB or III) without marked dislocation or vertical instability. Local soft-tissue infection. Combination procedure: Initially the lateral part of the clavicle is exposed by a 4 cm skin incision. After reduction of the fracture, stabilization is performed with a low profile locking distal clavicle plate. Using a special guiding device, a transclavicular-transcoracoidal hole is drilled under arthroscopic view. Additional vertical stabilization is arthroscopically achieved by shuttling the DogBone/FibreTape cerclage from the lateral portal cranially through the clavicular plate. The two ends of the FibreTape cerclage are brought cranially via adjacent holes of the locking plate while the DogBone button is placed under the coracoid process. Thus, plate bridging is achieved. Finally reduction is performed and the cerclage is secured by surgical knotting. Use of an arm sling for 6 weeks. Due to the fact that the described technique is a relatively new procedure, long-term results are lacking. In the short term, patients postoperatively report high subjective satisfaction without persistent pain.

  1. HEPA Filter Vulnerability Assessment

    International Nuclear Information System (INIS)

    GUSTAVSON, R.D.

    2000-01-01

    This assessment of High Efficiency Particulate Air (HEPA) filter vulnerability was requested by the USDOE Office of River Protection (ORP) to satisfy a DOE-HQ directive to evaluate the effect of filter degradation on the facility authorization basis assumptions. Within the scope of this assessment are ventilation system HEPA filters that are classified as Safety-Class (SC) or Safety-Significant (SS) components that perform an accident mitigation function. The objective of the assessment is to verify whether HEPA filters that perform a safety function during an accident are likely to perform as intended to limit release of hazardous or radioactive materials, considering factors that could degrade the filters. Filter degradation factors considered include aging, wetting of filters, exposure to high temperature, exposure to corrosive or reactive chemicals, and exposure to radiation. Screening and evaluation criteria were developed by a site-wide group of HVAC engineers and HEPA filter experts from published empirical data. For River Protection Project (RPP) filters, the only degradation factor that exceeded the screening threshold was for filter aging. Subsequent evaluation of the effect of filter aging on the filter strength was conducted, and the results were compared with required performance to meet the conditions assumed in the RPP Authorization Basis (AB). It was found that the reduction in filter strength due to aging does not affect the filter performance requirements as specified in the AB. A portion of the HEPA filter vulnerability assessment is being conducted by the ORP and is not part of the scope of this study. The ORP is conducting an assessment of the existing policies and programs relating to maintenance, testing, and change-out of HEPA filters used for SC/SS service. This document presents the results of a HEPA filter vulnerability assessment conducted for the River protection project as requested by the DOE Office of River Protection

  2. Distal finger replantation.

    Science.gov (United States)

    Scheker, Luis R; Becker, Giles W

    2011-03-01

    Reconstruction of the fingertip distal to the flexor tendon insertion by replantation remains controversial and technically challenging, but the anatomy of the fingertip has been well described and provides help in surgical planning. The open-book surgical technique is described with potential complications and is illustrated with clinical cases. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. Distal radioulnar joint injuries

    Directory of Open Access Journals (Sweden)

    Binu P Thomas

    2012-01-01

    Full Text Available Distal radioulnar joint is a trochoid joint relatively new in evolution. Along with proximal radioulnar joint , forearm bones and interosseous membrane, it allows pronosupination and load transmission across the wrist. Injuries around distal radioulnar joint are not uncommon, and are usually associated with distal radius fractures,fractures of the ulnar styloid and with the eponymous Galeazzi or Essex_Lopresti fractures. The injury can be purely involving the soft tissue especially the triangular fibrocartilage or the radioulnar ligaments.The patients usually present with ulnar sided wrist pain, features of instability, or restriction of rotation. Difficulty in carrying loads in the hand is a major constraint for these patients. Thorough clinical examination to localize point of tenderness and appropriate provocative tests help in diagnosis. Radiology and MRI are extremely useful, while arthroscopy is the gold standard for evaluation. The treatment protocols are continuously evolving and range from conservative, arthroscopic to open surgical methods. Isolated dislocation are uncommon. Basal fractures of the ulnar styloid tend to make the joint unstable and may require operative intervention. Chronic instability requires reconstruction of the stabilizing ligaments to avoid onset of arthritis. Prosthetic replacement in arthritis is gaining acceptance in the management of arthritis.

  4. Experimental evaluation of a new retrievable inferior vena cava filter for protection from acute pulmonary embolism in canine

    International Nuclear Information System (INIS)

    Zhou Chungao; Shi Haibing; Liu Sheng; Wang Chenghu; Liu Hairi; Li Linsun

    2007-01-01

    Objective: To evaluate the validity, safety and feasibility of a new retrieval inferior vena cava filter for the prevention of pulmonary embolism in an animal model. Methods: The model of deep iliofemoral venous thrombosis was established in 12 experimental dogs. In control group(6 experimental dogs), the deep venous thrombosis was made to fall off directly. In experimental group (6 experimental dogs), the deep venous thrombosis was made to fall off with an implanted filter in inferior vena cava. The filter's thrombus-trapping efficacy was evaluated by angiography of pulmonary artery, measurement of the mean pressure of pulmonary artery and arterial oxygen saturation before and after the deep venous thrombus falling off. Results: All filters implanted in the experimental dogs could successfully capture clot coming from deep venous thrombosis. There was no case of pulmonary embolism in experimental groups. On the other hand, pulmonary embolism occurred following the fall of deep venous thrombus in all dogs of control group. Conclusion: The retrievable inferior vena cava filter can effectively prevent from the pulmonary embolism due to falling off of the emboli from deep venous thrombosis. The process of implantation and retrieval is relatively simple and easy. (authors)

  5. Components for containment enclosures. Part 4: Ventilation and gas-cleaning systems such as filters, traps, safety and regulation valves, control and protection devices

    International Nuclear Information System (INIS)

    2001-01-01

    ISO 11933 consists of the following parts, under the general title Components for containment enclosures: Part 1: Glove/bag ports, bungs for glove/bag ports, enclosure rings and interchangeable units; Part 2: Gloves, welded bags, gaiters for remote-handling tongs and for manipulators; Part 3: Transfer systems such as plain doors, airlock chambers, double door transfer systems, leaktight connections for waste drums; Part 4: Ventilation and gas-cleaning systems such as filters, traps, safety and regulation valves, control and protection devices; Part 5: Penetrations for electrical and fluid circuits. This part of ISO 11933 specifies the design criteria and the characteristics of various components used for ventilation and gas-cleaning in containment enclosures. These components are either directly fixed to the containment enclosure wall, or used in the environment of a shielded or unshielded containment enclosure or line of such enclosures. They can be used alone or in conjunction with other mechanical components, including those specified in ISO 11933-1 and ISO 11933-3. This part of ISO 11933 is applicable to: filtering devices, including high-efficiency particulate air (HEPA) filters and iodine traps; safety valves and pressure regulators; systems ensuring the mechanical protection of containment enclosures; control and pressure-measurement devices

  6. A Novel Technique Using a Protection Filter During Fibrin Sheath Removal for Implanted Venous Access Device Dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Sotiriadis, Charalampos; Hajdu, Steven David [University Hospital of Lausanne, Cardiothoracic and Vascular Unit, Department of Radiology (Switzerland); Degrauwe, Sophie [University Hospital of Lausanne, Department of Cardiology (Switzerland); Barras, Heloise; Qanadli, Salah Dine, E-mail: salah.qanadli@chuv.ch [University Hospital of Lausanne, Cardiothoracic and Vascular Unit, Department of Radiology (Switzerland)

    2016-08-15

    With the increased use of implanted venous access devices (IVADs) for continuous long-term venous access, several techniques such as percutaneous endovascular fibrin sheath removal, have been described, to maintain catheter function. Most standard techniques do not capture the stripped fibrin sheath, which is subsequently released in the pulmonary circulation and may lead to symptomatic pulmonary embolism. The presented case describes an endovascular technique which includes stripping, capture, and removal of fibrin sheath using a novel filter device. A 64-year-old woman presented with IVAD dysfunction. Stripping was performed using a co-axial snare to the filter to capture the fibrin sheath. The captured fragment was subsequently removed for visual and pathological verification. No immediate complication was observed and the patient was discharged the day of the procedure.

  7. Cryptosporidium: A Guide to Water Filters

    Science.gov (United States)

    ... Tap Water Many but not all available home water filters remove Cryptosporidium . Some filter designs are more suitable for removal of Cryptosporidium than others. Filters that have the words "reverse osmosis" on the label protect against Cryptosporidium . Some other ...

  8. Controllable liquid colour-changing lenses with microfluidic channels for vision protection, camouflage and optical filtering based on soft lithography fabrication.

    Science.gov (United States)

    Zhang, Min; Li, Songjing

    2016-01-01

    In this work, liquid colour-changing lenses for vision protection, camouflage and optical filtering are developed by circulating colour liquids through microfluidic channels on the lenses manually. Soft lithography technology is applied to fabricate the silicone liquid colour-changing layers with microfluidic channels on the lenses instead of mechanical machining. To increase the hardness and abrasion resistance of the silicone colour-changing layers on the lenses, proper fabrication parameters such as 6:1 (mass ration) mixing proportion and 100 °C curing temperature for 2 h are approved for better soft lithography process of the lenses. Meanwhile, a new surface treatment for the irreversible bonding of silicone colour-changing layer with optical resin (CR39) substrate lens by using 5 % (volume ratio) 3-Aminopropyltriethoxysilane solution is proposed. Vision protection, camouflage and optical filtering functions of the lenses are investigated with different designs of the channels and multi-layer structures. Each application can not only well achieve their functional demands, but also shows the advantages of functional flexibility, rapid prototyping and good controllability compared with traditional ways. Besides optometry, some other designs and applications of the lenses are proposed for potential utility in the future.

  9. Distal corporoplasty for distal cylinders extrusion after penile prosthesis implantation.

    Science.gov (United States)

    Carrino, Maurizio; Chiancone, Francesco; Battaglia, Gaetano; Pucci, Luigi; Fedelini, Paolo

    2017-02-03

    Distal extrusion of cylinders is a potential complication of the penile prosthesis implantation. Several methods have been proposed for repairing a distal penile erosion. We present our preliminary experience in "Distal corporoplasty" technique. We enrolled 18 consecutive patients whose underwent a distal corporoplasty with simultaneous reimplantation of an "AMS 700 inflatable penile prosthesis (LGX)" from January 2013 to November 2015 at our hospital. All procedures were performed by a single surgical team. Intraoperative and postoperative complications have been classified and reported according to Satava6 and Clavien-Dindo (CD) system.7 Mean values with standard deviations (±SD) were computed and reported for all items. Mean age of the patients was 53.61 (±11.90) years. Mean body max index (BMI) was 24.22 (±2.51). Mean operative time was 85.2 (±13.1) minutes. Blood losses were minimal. No intraoperative complications are reported according to Satava classification. Four out of 18 patients (22.22%) experienced postoperative complications according to CD system. All patients had sexual intercourse for the first time postsurgery after a mean of 59.11 ± 2.08 days. Mean follow-up was 22.11 (±9.95). Distal extrusion of cylinders is a potential complication of the penile prosthesis implantation. Distal corporoplasty was first described by Mulcahy. He reported a series of 14 patients with a follow-up of about 2 years with optimal functional outcomes. Moreover, distal corporoplasty resulted in shorter operative time, better function, less pain, and fewer recurrences than Gortex windsock repair.10 In our experience, distal corporoplasty is a simple and safe procedure in the treatment of distal cylinders extrusion when the prosthetic material is not exposed to the exterior.

  10. Study of filterable materials and protection instruments by the use of radioactive aerosols; Etude de materiaux filtrants et d'appareils de protection a l'aide des aerosols radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Billard,; Chevalier,; Pradel, [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Many filtration problems can be studied by means of radioactive aerosols. For the investigations described in this paper we have chosen the solid disintegration products of radon, the radioactive gas formed from radium, because of the facilities of generation and measurement it offers. Radon and its daughters are in fact always present in the atmosphere in sufficient concentration for certain tests. In order to improve the sensitivity of the measurements, radon from uranium ore can be used. The technique of measuring by counting {alpha} particles is rapid and easy to employ. We have thus been able to define a test for filterable substances, and to check filtering installation and individual protection instruments. (author) [French] Les aerosols radioactifs permettent d'etudier de nombreux problemes de filtration. Pour les etudes decrites dans ce document, nous avons choisi les produits solides de desintegration du radon, gaz radioactif forme a partir du radium en raison des facilites de generation et de mesure. Le radon et ses descendants sont, en effet, toujours presents dans l'atmosphere en concentration suffisante pour certains essais. Pour ameliorer la sensibilite des mesures, il suffit d'utiliser le radon provenant de minerai d'uranium. La technique de mesure par comptage des particules {alpha} est rapide et facile a mettre en oeuvre. Nous avons pu ainsi definir un test pour les substances filtrantes et controler les installations de filtration et des appareils de protection individuelle. (auteur)

  11. Ubiquitous Nature of Distal Athero/Thromboembolic Events during Lower Extremity Atherectomy Procedures Involving the Superficial Femoral Artery

    Science.gov (United States)

    Wasty, Najam; Khakwani, M. Z.; Kotev, Spas; Boiangiu, Catalin; Hasan, Omar; Anna, Manjusha; Tayal, Rajiv; Kaid, Khalil; Baker, Gail; Cohen, Marc

    2016-01-01

    This study aims to evaluate occurrence, size, composition, and clinical significance of embolized debris during superficial femoral artery atherectomy using all commercially available atherectomy devices. Distal athero/thromboembolic events (DATE) are a universal phenomenon in lower extremity atherectomy procedures (LEAPs) due to the sheer volume of atheroma and the thrombus burden in peripheral arterial disease. Some of these events can be clinically significant. We prospectively gathered clinical and histopathological data on all commercially available atherectomy devices by using embolic protection devices (EPD) in every case. After intervention, the contents of EPD were examined both microscopically and macroscopically. Data from 59 consecutive patients undergoing LEAP were analyzed. DATE occurred 100% of the time. The composition of particulate debris varied with the device used. Grossly visible agglomerated debris was captured by the filter in the majority of patients 54/59 (91.5%). Clinically significant debris, defined by the Preventing Lower Extremity Distal Embolization Using Embolic Filter Protection registry as particle diameter > 0.2 cm, was found in 33/59 (56%) patients. The size of captured debris particles ranged from 0.1 to 2.4 mm. While DATE occurred in all patients, clinically significant DATE occurred in 56% patients undergoing LEAP regardless of the atherectomy device. In spite of a large fraction of the clinically significant debris occurring on our routine dual antiplatelet regimen, no patient suffered an amputation. Although DATE was prevented by the use of EPD in all 59 cases, more data are needed to determine whether the use of EPD translates into a long-term clinical benefit. Use of EPD and optimal thromboprophylaxis should be considered in patients, especially in the setting of compromised distal runoff. PMID:27867291

  12. Processing the papal encyclical through perceptual filters: Pope Francis, identity-protective cognition, and climate change concern.

    Science.gov (United States)

    Landrum, Asheley R; Lull, Robert B; Akin, Heather; Hasell, Ariel; Jamieson, Kathleen Hall

    2017-09-01

    Previous research suggests that when individuals encounter new information, they interpret it through perceptual 'filters' of prior beliefs, relevant social identities, and messenger credibility. In short, evaluations are not based solely on message accuracy, but also on the extent to which the message and messenger are amenable to the values of one's social groups. Here, we use the release of Pope Francis's 2015 encyclical as the context for a natural experiment to examine the role of prior values in climate change cognition. Based on our analysis of panel data collected before and after the encyclical's release, we find that political ideology moderated views of papal credibility on climate change for those participants who were aware of the encyclical. We also find that, in some contexts, non-Catholics who were aware of the encyclical granted Pope Francis additional credibility compared to the non-Catholics who were unaware of it, yet Catholics granted the Pope high credibility regardless of encyclical awareness. Importantly, papal credibility mediated the conditional relationships between encyclical awareness and acceptance of the Pope's messages on climate change. We conclude by discussing how our results provide insight into cognitive processing of new information about controversial issues. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Filter arrays

    Science.gov (United States)

    Page, Ralph H.; Doty, Patrick F.

    2017-08-01

    The various technologies presented herein relate to a tiled filter array that can be used in connection with performance of spatial sampling of optical signals. The filter array comprises filter tiles, wherein a first plurality of filter tiles are formed from a first material, the first material being configured such that only photons having wavelengths in a first wavelength band pass therethrough. A second plurality of filter tiles is formed from a second material, the second material being configured such that only photons having wavelengths in a second wavelength band pass therethrough. The first plurality of filter tiles and the second plurality of filter tiles can be interspersed to form the filter array comprising an alternating arrangement of first filter tiles and second filter tiles.

  14. Theoretical simulations of protective thin film Fabry-Pérot filters for integrated optical elements of diode pumped alkali lasers (DPAL

    Directory of Open Access Journals (Sweden)

    L. Quarrie

    2014-09-01

    Full Text Available The lifetime of Diode-Pumped Alkali Lasers (DPALs is limited by damage initiated by reaction of the glass envelope of its gain medium with rubidium vapor. Rubidium is absorbed into the glass and the rubidium cations diffuse through the glass structure, breaking bridging Si-O bonds. A damage-resistant thin film was developed enhancing high-optical transmission at natural rubidium resonance input and output laser beam wavelengths of 780 nm and 795 nm, while protecting the optical windows of the gain cell in a DPAL. The methodology developed here can be readily modified for simulation of expected transmission performance at input pump and output laser wavelengths using different combination of thin film materials in a DPAL. High coupling efficiency of the light through the gas cell was accomplished by matching the air-glass and glass-gas interfaces at the appropriate wavelengths using a dielectric stack of high and low index of refraction materials selected to work at the laser energies and protected from the alkali metal vapor in the gain cell. Thin films as oxides of aluminum, zirconium, tantalum, and silicon were selected allowing the creation of Fabry-Perot optical filters on the optical windows achieving close to 100% laser transmission in a solid optic combination of window and highly reflective mirror. This approach allows for the development of a new whole solid optic laser.

  15. Efficacy of Carotid Artery Stenting by the Universal Protection Method.

    Science.gov (United States)

    Goto, Shunsaku; Ohshima, Tomotaka; Kato, Kyozo; Izumi, Takashi; Wakabayashi, Toshihiko

    2018-04-18

    To avoid distal plaques embolization during carotid artery stenting, we developed Universal Protection Method that combined the use of a proximal common carotid artery balloon, an external carotid artery balloon, and a distal internal carotid artery filter, with continuous flow reversal to the femoral vein. Herein, we assessed the efficacy of the Universal Protection Method by comparing stenting outcomes before and after its introduction. We assessed outcomes for 115 cases before and 41 cases after the Universal Protection Method was adopted (non-Universal Protection Method and Universal Protection Method groups, respectively). We then compared procedure details, magnetic resonance imaging (within 48 hours after the procedure), intraprocedural complications, and postoperative stroke rates. Ischemic stroke was not observed in the Universal Protection Method group, but 1 major stroke and 2 minor strokes were observed in the non-Universal Protection Method group. High-intensity areas were seen in 6 (15.0%) and 49 (42.6%) cases in the Universal Protection Method and non-Universal Protection Method groups, respectively (P = .001). Contrastingly, intraprocedural complications were observed in 9 (22.5%) and 21 (18.3%) cases in the Universal Protection Method and non-Universal Protection Method groups, respectively. Among these intraprocedural complication cases, high-intensity areas were observed in 1 case (11.1%) in the Universal Protection Method group and in 15 cases (71.4%) in the non-Universal Protection Method group. Universal Protection Method is a safe technique that is applicable to all patients undergoing carotid artery stenting, irrespective of individual risk factors. Notably, the incidence rates of both distal embolization and unexpected intraprocedural complications are low. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  16. A Chemical-Biological-Radio-Nuclear (CBRN) Filter can be Added to the Air-Outflow Port of a Ventilator to Protect a Home Ventilated Patient From Inhalation of Toxic Industrial Compounds.

    Science.gov (United States)

    Be'eri, Eliezer; Owen, Simon; Beeri, Maurit; Millis, Scott R; Eisenkraft, Arik

    2018-02-21

    Chemical-biological-radio-nuclear (CBRN) gas masks are the standard means for protecting the general population from inhalation of toxic industrial compounds (TICs), for example after industrial accidents or terrorist attacks. However, such gas masks would not protect patients on home mechanical ventilation, as ventilator airflow would bypass the CBRN filter. We therefore evaluated in vivo the safety of adding a standard-issue CBRN filter to the air-outflow port of a home ventilator, as a method for providing TIC protection to such patients. Eight adult patients were included in the study. All had been on stable, chronic ventilation via a tracheostomy for at least 3 months before the study. Each patient was ventilated for a period of 1 hour with a standard-issue CBRN filter canister attached to the air-outflow port of their ventilator. Physiological and airflow measurements were made before, during, and after using the filter, and the patients reported their subjective sensation of ventilation continuously during the trial. For all patients, and throughout the entire study, no deterioration in any of the measured physiological parameters and no changes in measured airflow parameters were detected. All patients felt no subjective difference in the sensation of ventilation with the CBRN filter canister in situ, as compared with ventilation without it. This was true even for those patients who were breathing spontaneously and thus activating the ventilator's trigger/sensitivity function. No technical malfunctions of the ventilators occurred after addition of the CBRN filter canister to the air-outflow ports of the ventilators. A CBRN filter canister can be added to the air-outflow port of chronically ventilated patients, without causing an objective or subjective deterioration in the quality of the patients' mechanical ventilation. (Disaster Med Public Health Preparedness. 2018;page 1 of 5).

  17. Filter cake breaker systems

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, Marcelo H.F. [Poland Quimica Ltda., Duque de Caxias, RJ (Brazil)

    2004-07-01

    Drilling fluids filter cakes are based on a combination of properly graded dispersed particles and polysaccharide polymers. High efficiency filter cakes are formed by these combination , and their formation on wellbore walls during the drilling process has, among other roles, the task of protecting the formation from instantaneous or accumulative invasion of drilling fluid filtrate, granting stability to well and production zones. Filter cake minimizes contact between drilling fluid filtrate and water, hydrocarbons and clay existent in formations. The uniform removal of the filter cake from the entire interval is a critical factor of the completion process. The main methods used to breaking filter cake are classified into two groups, external or internal, according to their removal mechanism. The aim of this work is the presentation of these mechanisms as well their efficiency. (author)

  18. Traumatic Distal Ulnar Artery Thrombosis

    Directory of Open Access Journals (Sweden)

    Ahmet A. Karaarslan

    2014-01-01

    Full Text Available This paper is about a posttraumatic distal ulnar artery thrombosis case that has occurred after a single blunt trauma. The ulnar artery thrombosis because of chronic trauma is a frequent condition (hypothenar hammer syndrome but an ulnar artery thrombosis because of a single direct blunt trauma is rare. Our patient who has been affected by a single blunt trauma to his hand and developed ulnar artery thrombosis has been treated by resection of the thrombosed ulnar artery segment. This report shows that a single blunt trauma can cause distal ulnar artery thrombosis in the hand and it can be treated merely by thrombosed segment resection in suitable cases.

  19. Rectifier Filters

    Directory of Open Access Journals (Sweden)

    Y. A. Bladyko

    2010-01-01

    Full Text Available The paper contains definition of a smoothing factor which is suitable for any rectifier filter. The formulae of complex smoothing factors have been developed for simple and complex passive filters. The paper shows conditions for application of calculation formulae and filters

  20. Ceramic fiber reinforced filter

    Science.gov (United States)

    Stinton, David P.; McLaughlin, Jerry C.; Lowden, Richard A.

    1991-01-01

    A filter for removing particulate matter from high temperature flowing fluids, and in particular gases, that is reinforced with ceramic fibers. The filter has a ceramic base fiber material in the form of a fabric, felt, paper of the like, with the refractory fibers thereof coated with a thin layer of a protective and bonding refractory applied by chemical vapor deposition techniques. This coating causes each fiber to be physically joined to adjoining fibers so as to prevent movement of the fibers during use and to increase the strength and toughness of the composite filter. Further, the coating can be selected to minimize any reactions between the constituents of the fluids and the fibers. A description is given of the formation of a composite filter using a felt preform of commercial silicon carbide fibers together with the coating of these fibers with pure silicon carbide. Filter efficiency approaching 100% has been demonstrated with these filters. The fiber base material is alternately made from aluminosilicate fibers, zirconia fibers and alumina fibers. Coating with Al.sub.2 O.sub.3 is also described. Advanced configurations for the composite filter are suggested.

  1. Numerical study of canister filters with alternatives filter cap configurations

    Science.gov (United States)

    Mohammed, A. N.; Daud, A. R.; Abdullah, K.; Seri, S. M.; Razali, M. A.; Hushim, M. F.; Khalid, A.

    2017-09-01

    Air filtration system and filter play an important role in getting a good quality air into turbo machinery such as gas turbine. The filtration system and filter has improved the quality of air and protect the gas turbine part from contaminants which could bring damage. During separation of contaminants from the air, pressure drop cannot be avoided but it can be minimized thus helps to reduce the intake losses of the engine [1]. This study is focused on the configuration of the filter in order to obtain the minimal pressure drop along the filter. The configuration used is the basic filter geometry provided by Salutary Avenue Manufacturing Sdn Bhd. and two modified canister filter cap which is designed based on the basic filter model. The geometries of the filter are generated by using SOLIDWORKS software and Computational Fluid Dynamics (CFD) software is used to analyse and simulates the flow through the filter. In this study, the parameters of the inlet velocity are 0.032 m/s, 0.063 m/s, 0.094 m/s and 0.126 m/s. The total pressure drop produce by basic, modified filter 1 and 2 is 292.3 Pa, 251.11 Pa and 274.7 Pa. The pressure drop reduction for the modified filter 1 is 41.19 Pa and 14.1% lower compared to basic filter and the pressure drop reduction for modified filter 2 is 17.6 Pa and 6.02% lower compared to the basic filter. The pressure drops for the basic filter are slightly different with the Salutary Avenue filter due to limited data and experiment details. CFD software are very reliable in running a simulation rather than produces the prototypes and conduct the experiment thus reducing overall time and cost in this study.

  2. Filter apparatus

    International Nuclear Information System (INIS)

    Butterworth, D.J.

    1980-01-01

    This invention relates to liquid filters, precoated by replaceable powders, which are used in the production of ultra pure water required for steam generation of electricity. The filter elements are capable of being installed and removed by remote control so that they can be used in nuclear power reactors. (UK)

  3. Spleen-preserving distal pancreatectomy in trauma.

    Science.gov (United States)

    Schellenberg, Morgan; Inaba, Kenji; Cheng, Vincent; Bardes, James M; Lam, Lydia; Benjamin, Elizabeth; Matsushima, Kazuhide; Demetriades, Demetrios

    2018-01-01

    Traumatic injuries to the distal pancreas are infrequent. Universally accepted recommendations about the need for routine splenectomy with distal pancreatectomy do not exist. The aims of this study were to compare outcomes after distal pancreatectomy and splenectomy versus spleen-preserving distal pancreatectomy, and to define the appropriate patient population for splenic preservation. All patients who underwent distal pancreatectomy (January 1, 2007, to December 31, 2014) were identified from the National Trauma Data Bank. Patients with concomitant splenic injury and those who underwent partial splenectomy were excluded. Demographics, clinical data, procedures, and outcomes were collected. Study groups were defined by surgical procedure: distal pancreatectomy and splenectomy versus spleen-preserving distal pancreatectomy. Baseline characteristics between groups were compared with univariate analysis. Multivariate analysis was performed with logistic and linear regression to examine differences in outcomes. Over the 8-year study period, 2,223 patients underwent distal pancreatectomy. After excluding 1,381 patients with concomitant splenic injury (62%) and 8 (pancreatectomy and splenectomy, those who underwent spleen-preserving distal pancreatectomy were younger (p pancreatectomy (p = 0.017). Complications, mortality, and intensive care unit LOS were not significantly different. In young patients after blunt trauma who are not severely injured, a spleen-preserving distal pancreatectomy should be considered to allow for conservation of splenic function and a shorter hospital LOS. In all other patients, the surgeon should not hesitate to remove the spleen with the distal pancreas. Therapy, level IV.

  4. Inorganic UV filters

    Directory of Open Access Journals (Sweden)

    Eloísa Berbel Manaia

    2013-06-01

    Full Text Available Nowadays, concern over skin cancer has been growing more and more, especially in tropical countries where the incidence of UVA/B radiation is higher. The correct use of sunscreen is the most efficient way to prevent the development of this disease. The ingredients of sunscreen can be organic and/or inorganic sun filters. Inorganic filters present some advantages over organic filters, such as photostability, non-irritability and broad spectrum protection. Nevertheless, inorganic filters have a whitening effect in sunscreen formulations owing to the high refractive index, decreasing their esthetic appeal. Many techniques have been developed to overcome this problem and among them, the use of nanotechnology stands out. The estimated amount of nanomaterial in use must increase from 2000 tons in 2004 to a projected 58000 tons in 2020. In this context, this article aims to analyze critically both the different features of the production of inorganic filters (synthesis routes proposed in recent years and the permeability, the safety and other characteristics of the new generation of inorganic filters.

  5. Filter systems

    International Nuclear Information System (INIS)

    Vanin, V.R.

    1990-01-01

    The multidetector systems for high resolution gamma spectroscopy are presented. The observable parameters for identifying nuclides produced simultaneously in the reaction are analysed discussing the efficiency of filter systems. (M.C.K.)

  6. Protective

    Directory of Open Access Journals (Sweden)

    Wessam M. Abdel-Wahab

    2013-10-01

    Full Text Available Many active ingredients extracted from herbal and medicinal plants are extensively studied for their beneficial effects. Antioxidant activity and free radical scavenging properties of thymoquinone (TQ have been reported. The present study evaluated the possible protective effects of TQ against the toxicity and oxidative stress of sodium fluoride (NaF in the liver of rats. Rats were divided into four groups, the first group served as the control group and was administered distilled water whereas the NaF group received NaF orally at a dose of 10 mg/kg for 4 weeks, TQ group was administered TQ orally at a dose of 10 mg/kg for 5 weeks, and the NaF-TQ group was first given TQ for 1 week and was secondly administered 10 mg/kg/day NaF in association with 10 mg/kg TQ for 4 weeks. Rats intoxicated with NaF showed a significant increase in lipid peroxidation whereas the level of reduced glutathione (GSH and the activity of superoxide dismutase (SOD, catalase (CAT, glutathione S-transferase (GST and glutathione peroxidase (GPx were reduced in hepatic tissues. The proper functioning of the liver was also disrupted as indicated by alterations in the measured liver function indices and biochemical parameters. TQ supplementation counteracted the NaF-induced hepatotoxicity probably due to its strong antioxidant activity. In conclusion, the results obtained clearly indicated the role of oxidative stress in the induction of NaF toxicity and suggested hepatoprotective effects of TQ against the toxicity of fluoride compounds.

  7. Development of Filter-Blower Unit for use in the Advanced Nuclear Biological Chemical Protection System (ANBCPS) Helicopter/Transport-aircraft version

    NARCIS (Netherlands)

    Sabel, R.; Reffeltrath, P.A.; Jonkman, A.; Post, T.

    2006-01-01

    As a participant in the three-nation partnership for development of the ANBCP-S for use in Helicopters, Transport Aircraft and Fast Jet, the Royal Netherlands Airforce (RNLAF) picked up the challenge to design a Filter- Blower-Unit (FBU). Major Command (MajCom) of the RNLAF set priority to develop a

  8. Stochastic stacking without filters

    International Nuclear Information System (INIS)

    Johnson, R.P.; Marriner, J.

    1982-12-01

    The rate of accumulation of antiprotons is a critical factor in the design of p anti p colliders. A design of a system to accumulate higher anti p fluxes is presented here which is an alternative to the schemes used at the CERN AA and in the Fermilab Tevatron I design. Contrary to these stacking schemes, which use a system of notch filters to protect the dense core of antiprotons from the high power of the stack tail stochastic cooling, an eddy current shutter is used to protect the core in the region of the stack tail cooling kicker. Without filters one can have larger cooling bandwidths, better mixing for stochastic cooling, and easier operational criteria for the power amplifiers. In the case considered here a flux of 1.4 x 10 8 per sec is achieved with a 4 to 8 GHz bandwidth

  9. Posttraumatic osteolysis of the distal clavicula end

    International Nuclear Information System (INIS)

    Hermanns, P.H.; Beeger, R.; Koetter, D.; Hamburg Univ.

    1981-01-01

    Posttraumatic osteolysis of bone is rare. Its etiology is unknown. A case of posttraumatic osteolysis of the distal clavicle end is reported. Differentialdiagnostical and ethiological relations are discussed. The literature of posttraumatic osteolysis especially of distal clavicle osteolysis is reported. (orig.) [de

  10. Contemporary Management of Primary Distal Urethral Cancer

    NARCIS (Netherlands)

    Traboulsi, S.L.; Witjes, J.A.; Kassouf, W.

    2016-01-01

    Primary urethral cancer is one of the rare urologic tumors. Distal urethral tumors are usually less advanced at diagnosis compared with proximal tumors and have a good prognosis if treated appropriately. Low-stage distal tumors can be managed successfully with a surgical approach in men or radiation

  11. Generalised Filtering

    Directory of Open Access Journals (Sweden)

    Karl Friston

    2010-01-01

    Full Text Available We describe a Bayesian filtering scheme for nonlinear state-space models in continuous time. This scheme is called Generalised Filtering and furnishes posterior (conditional densities on hidden states and unknown parameters generating observed data. Crucially, the scheme operates online, assimilating data to optimize the conditional density on time-varying states and time-invariant parameters. In contrast to Kalman and Particle smoothing, Generalised Filtering does not require a backwards pass. In contrast to variational schemes, it does not assume conditional independence between the states and parameters. Generalised Filtering optimises the conditional density with respect to a free-energy bound on the model's log-evidence. This optimisation uses the generalised motion of hidden states and parameters, under the prior assumption that the motion of the parameters is small. We describe the scheme, present comparative evaluations with a fixed-form variational version, and conclude with an illustrative application to a nonlinear state-space model of brain imaging time-series.

  12. Filter This

    Directory of Open Access Journals (Sweden)

    Audrey Barbakoff

    2011-03-01

    Full Text Available In the Library with the Lead Pipe welcomes Audrey Barbakoff, a librarian at the Milwaukee Public Library, and Ahniwa Ferrari, Virtual Experience Manager at the Pierce County Library System in Washington, for a point-counterpoint piece on filtering in libraries. The opinions expressed here are those of the authors, and are not endorsed by their employers. [...

  13. A PROSPECTIVE STUDY OF DISTAL TIBIAL FRACTURES BY MIPO (LCP

    Directory of Open Access Journals (Sweden)

    Chandra Sekharam Naidu

    2015-05-01

    Full Text Available INTRODUCTION: D istal tibial fractures represent a significant challenge to most of the surgeons even today. They constitute 1 - 10% of all lower extremity fractures . 1 The difficulty in treating the fractures of distal tibial end is exemplif ied by orthopedists, who in the first half of twentieth century, believed these injuries were so severe and fraught with so many complications, that these fractures were deemed not amenable for surgical reconstruction . 2 Conservative treatment by POP cast l ead to prolonged immobilization, leading to ankle and knee stiffness affecting quality of life of the patient . 3 Operative treatment is indicated for most tibial fractures caused by high energy trauma. Operative treatment allows early motion, and avoids sho rtening and other complications associated with prolonged immobilization . 4 The fundamental goal of treatment of distal tibial fractures is restoration of normal or near normal alignment and articular congruity and finally to obtain a well healed fracture; pain free weight bearing ; and functional ROM of ankle joint. For the past decade, plating has been successful in treating complex fractures of the lower extremity especially distal tibia . 5 Conventional ORIF have been associated with complications like infe ction and delayed or non - union due to devitalisation of bony fragments and additional damage to the soft tissues . 6 To improve fracture healing, more “biological” methods have been developed in the last decade to lessen the surgical dissection, preserving b lood supply to bony fragments and containing at least partially the fracture haematoma . 7 Recently, the trend is towards use of a Locking compression plate for treatment of fractures of the distal part of the tibia 8 . Compared with a conventional plate, a Lo cking compression plate imparts a higher degree of stability and provides better protection against primary and secondary losses of reduction and minimization of bone

  14. Endovascular rescue of a fused monorail balloon and cerebral protection device.

    Science.gov (United States)

    Campbell, John E; Bates, Mark C; Elmore, Michael

    2007-08-01

    To present a case of successful endovascular retrieval of a monorail predilation balloon fused to an embolic protection device (EPD) in the distal internal carotid artery (ICA) of a high-risk symptomatic patient. A 60-year-old man with documented systemic atherosclerotic disease had a severe (>70%) restenosis in the left ICA 3 years after endarterectomy. He was scheduled for carotid artery stenting (CAS) with cerebral protection; however, he developed unstable angina and was transferred to our facility, where the admitting team decided that staged CAS followed by coronary bypass grafting would be the best option. During the CAS procedure, a 6-mm AccuNet filter was passed across the lesion via a 6-F carotid sheath and deployed in the distal ICA without incident. However, the 4-x20-mm predilation monorail balloon was then advanced without visualizing the markers, resulting in inadvertent aggressive interaction that trapped the balloon's tip in the filter. Several maneuvers to separate the devices were unsuccessful. Finally, the filter/balloon combination was moved gently retrograde until the balloon was straddling the subtotal ICA lesion. The lesion was dilated to 4 mm with the balloon, and the sheath was gently advanced across the lesion as the balloon was deflated. Angiography excluded interval occlusion of the filter from the embolic debris during the aforementioned aggressive maneuvers and documented antegrade flow. The filter was slowly withdrawn into the 6-F sheath with simultaneous aspiration. A second 6-mm filter was deployed, and the procedure was completed satisfactorily. The patient did well, with no neurological sequelae. EPDs are an essential in carotid artery stenting and, keeping in mind the potential risks associated with their use, will help the operator avoid complications such as this one.

  15. The dry filter method for passive filtered venting of the containment

    International Nuclear Information System (INIS)

    Freis, Daniel; Tietsch, Wolfgang; Obenland, Ralf; Kroes, Bert; Martinsteg, Hans

    2013-01-01

    Filtered Venting is a mitigative emergency measure to protect the containment from pressure failure in case of a severe accident. Filtered vent systems which are based on the Dry Filter Method (DFM) are proven technology, work completely passive, meet all functional requirements and show excellent performance with respect to filter efficiency. With such a system the release of radioactive fission products to the environment can be effectively minimized. Short and long term land contaminations can be avoided. (orig.)

  16. The intractable cigarette 'filter problem'.

    Science.gov (United States)

    Harris, Bradford

    2011-05-01

    When lung cancer fears emerged in the 1950s, cigarette companies initiated a shift in cigarette design from unfiltered to filtered cigarettes. Both the ineffectiveness of cigarette filters and the tobacco industry's misleading marketing of the benefits of filtered cigarettes have been well documented. However, during the 1950s and 1960s, American cigarette companies spent millions of dollars to solve what the industry identified as the 'filter problem'. These extensive filter research and development efforts suggest a phase of genuine optimism among cigarette designers that cigarette filters could be engineered to mitigate the health hazards of smoking. This paper explores the early history of cigarette filter research and development in order to elucidate why and when seemingly sincere filter engineering efforts devolved into manipulations in cigarette design to sustain cigarette marketing and mitigate consumers' concerns about the health consequences of smoking. Relevant word and phrase searches were conducted in the Legacy Tobacco Documents Library online database, Google Patents, and media and medical databases including ProQuest, JSTOR, Medline and PubMed. 13 tobacco industry documents were identified that track prominent developments involved in what the industry referred to as the 'filter problem'. These reveal a period of intense focus on the 'filter problem' that persisted from the mid-1950s to the mid-1960s, featuring collaborations between cigarette producers and large American chemical and textile companies to develop effective filters. In addition, the documents reveal how cigarette filter researchers' growing scientific knowledge of smoke chemistry led to increasing recognition that filters were unlikely to offer significant health protection. One of the primary concerns of cigarette producers was to design cigarette filters that could be economically incorporated into the massive scale of cigarette production. The synthetic plastic cellulose acetate

  17. Conceptualizing distal drivers in land use competition

    DEFF Research Database (Denmark)

    Niewhöner, Jörg; Nielsen, Jonas Ø; Gasparri, Gasparri

    2016-01-01

    This introductory chapter explores the notion of ‘distal drivers’ in land use competition. Research has moved beyond proximate causes of land cover and land use change to focus on the underlying drivers of these dynamics. We discuss the framework of telecoupling within human–environment systems...... as a first step to come to terms with the increasingly distal nature of driving forces behind land use practices. We then expand the notion of distal as mainly a measure of Euclidian space to include temporal, social, and institutional dimensions. This understanding of distal widens our analytical scope...... for the analysis of land use competition as a distributed process to consider the role of knowledge and power, technology, and different temporalities within a relational or systemic analysis of practices of land use competition. We conclude by pointing toward the historical and social contingency of land use...

  18. Distal technologies and type 1 diabetes management.

    Science.gov (United States)

    Duke, Danny C; Barry, Samantha; Wagner, David V; Speight, Jane; Choudhary, Pratik; Harris, Michael A

    2018-02-01

    Type 1 diabetes requires intensive self-management to avoid acute and long-term health complications. In the past two decades, substantial advances in technology have enabled more effective and convenient self-management of type 1 diabetes. Although proximal technologies (eg, insulin pumps, continuous glucose monitors, closed-loop and artificial pancreas systems) have been the subject of frequent systematic and narrative reviews, distal technologies have received scant attention. Distal technologies refer to electronic systems designed to provide a service remotely and include heterogeneous systems such as telehealth, mobile health applications, game-based support, social platforms, and patient portals. In this Review, we summarise the empirical literature to provide current information about the effectiveness of available distal technologies to improve type 1 diabetes management. We also discuss privacy, ethics, and regulatory considerations, issues of global adoption, knowledge gaps in distal technology, and recommendations for future directions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Genetics Home Reference: distal arthrogryposis type 1

    Science.gov (United States)

    ... 1 is a disorder characterized by joint deformities (contractures) that restrict movement in the hands and feet. ... distal arthrogryposis type 1 . However, researchers speculate that contractures may be related to problems with muscle contraction ...

  20. Potassium secretion in mammalian distal colon

    DEFF Research Database (Denmark)

    Sørensen, Mads Vaarby

    2009-01-01

    Epithelial organs adjust the „inner milieu“ of the body and are crucial for all homeostatic processes. Epithelial transport of different solutes and water is regulated phenomena. The regulation processes include both long term hormonal regulation and short term local agonist mediated regulation....... This research project is the summary of 3 original papers addressing the functional role of different regulating factors on ion transport in mouse distal colon. The first paper addresses the effect of luminal nucleotides on electrogenic Na+ absorption. The distal colon, like the distal nephron is an aldosterone......-sensitive tissue and participates in the regulation of Na+ excretion. In the distal nephron it was found that luminal nucleotides inhibit ENaC-mediated Na+ absorption. Here it was addressed whether luminal nucleotides regulate Na+ absorption and if so, which of the known luminal P2 receptors are involved. Using...

  1. 垃圾邮件防止法之探讨%An Analysis of the Draft of Protection in Spam E-mails and Filters

    Institute of Scientific and Technical Information of China (English)

    曾胜珍

    2013-01-01

    Modern people use e-mail to connect a majority of life , even busi-ness, including customer and vendor communication , marketing, and filing official documents .The most recent development , mass electronic mailing-known in the computer industry vernacular as “spam”—allows businesses to contact millions of potential customers , large numbers of them can be extremely inconvenient , with al-most no cost per message .When we discover that our most recent e-mails were not delivered to recipients by using a major Internet Service Provider (“ISP”) , be-cause we were recently listed on an automated block list as a sender of unwanted bulk commercial e-mail (“spam”) .The most efficient approach for a sender im-properly included on a block list or a spam filter is to request removal directly from that list or filter .The paper will provide the suggestions of proposed amendments in the future legislature .%因特网的发展与便利形成现代社会中不可或缺的存在,电子邮件的便利跨越时空的限制,使得人与人之间的联系紧密维护,然而垃圾邮件( Junk E-mails)却同时造成使用人相当的困扰,不但增加层层过滤信件的时间,也引发部分正常信件经过封锁名单( Block Lists )及垃圾邮件清除器( Spam Filters )的使用,反而被归类到垃圾邮件的分类。本文建议应考虑垃圾邮件发信人查缉不易与变换位置迅速的缺点,参考美国经验并检视美国法规制度与实务判决等方面,再衡量既有法制解决此类问题将面临的困难与障碍,从而提出设立新法的建议与内容,希冀能为垃圾邮件防止法提供省思与依据。

  2. Normal distal pulmonary vein anatomy

    Directory of Open Access Journals (Sweden)

    Wiesława Klimek-Piotrowska

    2016-01-01

    Full Text Available Background. It is well known that the pulmonary veins (PVs, especially their myocardial sleeves play a critical role in the initiation and maintenance of atrial fibrillation. Understanding the PV anatomy is crucial for the safety and efficacy of all procedures performed on PVs. The aim of this study was to present normal distal PV anatomy and to create a juxtaposition of all PV ostium variants.Methods. A total of 130 randomly selected autopsied adult human hearts (Caucasian were examined. The number of PVs ostia was evaluated and their diameter was measured. The ostium-to-last-tributary distance and macroscopic presence of myocardial sleeves were also evaluated.Results. Five hundred forty-one PV ostia were identified. Four classical PV ostia patterns (two left and two right PVs were observed in 70.8% of all cases. The most common variant was the classical pattern with additional middle right PV (19.2%, followed by the common ostium for the left superior and the inferior PVs (4.44%. Mean diameters of PV ostia (for the classical pattern were: left superior = 13.8 ± 2.9 mm; left inferior = 13.3 ± 3.4 mm; right superior = 14.3 ± 2.9 mm; right inferior = 13.7 ± 3.3 mm. When present, the additional middle right PV ostium had the smallest PV ostium diameter in the heart (8.2 ± 4.1 mm. The mean ostium-to-last-tributary (closest to the atrium distances were: left superior = 15.1 ± 4.6 mm; left inferior = 13.5 ± 4.0 mm; right superior = 11.8 ± 4.0 mm; right inferior = 11.0 ± 3.7 mm. There were no statistically significant differences between sexes in ostia diameters and ostium-to-last-tributary distances.Conclusion. Only 71% of the cases have four standard pulmonary veins. The middle right pulmonary vein is present in almost 20% of patients. Presented data can provide useful information for the clinicians during interventional procedures or radiologic examinations of PVs.

  3. Bag filters

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, M; Komeda, I; Takizaki, K

    1982-01-01

    Bag filters are widely used throughout the cement industry for recovering raw materials and products and for improving the environment. Their general mechanism, performance and advantages are shown in a classification table, and there are comparisons and explanations. The outer and inner sectional construction of the Shinto ultra-jet collector for pulverized coal is illustrated and there are detailed descriptions of dust cloud prevention, of measures used against possible sources of ignition, of oxygen supply and of other topics. Finally, explanations are given of matters that require careful and comprehensive study when selecting equipment.

  4. Digital filters

    CERN Document Server

    Hamming, Richard W

    1997-01-01

    Digital signals occur in an increasing number of applications: in telephone communications; in radio, television, and stereo sound systems; and in spacecraft transmissions, to name just a few. This introductory text examines digital filtering, the processes of smoothing, predicting, differentiating, integrating, and separating signals, as well as the removal of noise from a signal. The processes bear particular relevance to computer applications, one of the focuses of this book.Readers will find Hamming's analysis accessible and engaging, in recognition of the fact that many people with the s

  5. Decontamination of two filter boxes after a fire

    International Nuclear Information System (INIS)

    Cerre, P.; Mestre, E.; Lafitte, T.

    1961-01-01

    As a primary filter of the venting system caught fire in a hot cell of the Laboratory of Examination of Irradiated Fuels, this filter (as well as the secondary filter) has been removed, wrapped in polyvinyl sheets, and transported into the decontamination station. The authors report the details of the handling and decontamination operations: modifications to the station arrangement, measures of radiation protection, decontamination and measurements, observations made when disassembling the filter and filter-boxes [fr

  6. Filter element, particularly for cleaning hot gases

    International Nuclear Information System (INIS)

    Hoelter, H.

    1980-01-01

    The fibres of the filter cloth consists of aluminium silicate. The filter cloth lies on a mesh made of ceramic material, e.g. 99% SiO 2 and 1% Cr 2 O 3 . In order to reduce the bending stress at the edges of the filter cloth, particularly when cleaning, there are bend protection devices in the form of curved surfaces made of felt or similar material in the edge areas. (DG) [de

  7. Convergent Filter Bases

    Directory of Open Access Journals (Sweden)

    Coghetto Roland

    2015-09-01

    Full Text Available We are inspired by the work of Henri Cartan [16], Bourbaki [10] (TG. I Filtres and Claude Wagschal [34]. We define the base of filter, image filter, convergent filter bases, limit filter and the filter base of tails (fr: filtre des sections.

  8. Higher safety and saving of filter material with multi-way sorption filters

    International Nuclear Information System (INIS)

    Ohlmeyer, M.; Benzel, M.

    1978-01-01

    The multi-way filter 'Nuclear Karlsruhe' satisfies the requirements of operational safety, high utilisation of the filter material and low pressure drop. An important factor contributing to increased operational safety is due to the fact that the nearly total utilisation of the filter material eliminates the need for optimisation weighing costs against safety. The reduction in filter material consumption reduces not only the direct procurement costs but also the costs of nuclear plants, is radioactive. This contributes in several respects towards a better protection of the environment. The MWS filter can also be used, and presents the same advantages, in non-nuclear plants. (orig.) [de

  9. Distal splenorenal shunt with partial spleen resection

    Directory of Open Access Journals (Sweden)

    Gajin Predrag

    2007-01-01

    Full Text Available Introduction: Hypersplenism is a common complication of portal hypertension. Cytopenia in hypersplenism is predominantly caused by splenomegaly. Distal splenorenal shunt (Warren with partial spleen resection is an original surgical technique that regulates cytopenia by reduction of the enlarged spleen. Objective. The aim of our study was to present the advantages of distal splenorenal shunt (Warren with partial spleen resection comparing morbidity and mortality in a group of patients treated by distal splenorenal shunt with partial spleen resection with a group of patients treated only by a distal splenorenal shunt. Method. From 1995 to 2003, 41 patients with portal hypertension were surgically treated due to hypersplenism and oesophageal varices. The first group consisted of 20 patients (11 male, mean age 42.3 years who were treated by distal splenorenal shunt with partial spleen resection. The second group consisted of 21 patients (13 male, mean age 49.4 years that were treated by distal splenorenal shunt only. All patients underwent endoscopy and assessment of oesophageal varices. The size of the spleen was evaluated by ultrasound, CT or by scintigraphy. Angiography was performed in all patients. The platelet and white blood cell count and haemoglobin level were registered. Postoperatively, we noted blood transfusion, complications and total hospital stay. Follow-up period was 12 months, with first checkup after one month. Results In the first group, only one patient had splenomegaly postoperatively (5%, while in the second group there were 13 patients with splenomegaly (68%. Before surgery, the mean platelet count in the first group was 51.6±18.3x109/l, to 118.6±25.4x109/l postoperatively. The mean platelet count in the second group was 67.6±22.8x109/l, to 87.8±32.1x109/l postoperatively. Concerning postoperative splenomegaly, statistically significant difference was noted between the first and the second group (p<0.05. Comparing the

  10. Contemporary Management of Primary Distal Urethral Cancer.

    Science.gov (United States)

    Traboulsi, Samer L; Witjes, Johannes Alfred; Kassouf, Wassim

    2016-11-01

    Primary urethral cancer is one of the rare urologic tumors. Distal urethral tumors are usually less advanced at diagnosis compared with proximal tumors and have a good prognosis if treated appropriately. Low-stage distal tumors can be managed successfully with a surgical approach in men or radiation therapy in women. There are no clear-cut indications for the choice of the most appropriate treatment modality. Organ-preserving modalities have shown effective and should be used whenever they do not compromise the oncological safety to decrease the physical and psychological trauma of dismemberment or loss of sexual/urinary function. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Spontaneous distal rupture of the plantar fascia.

    Science.gov (United States)

    Gitto, Salvatore; Draghi, Ferdinando

    2018-07-01

    Spontaneous ruptures of the plantar fascia are uncommon injuries. They typically occur at its calcaneal insertion and usually represent a complication of plantar fasciitis and local treatment with steroid injections. In contrast, distal ruptures commonly result from traumatic injuries. We describe the case of a spontaneous distal rupture of the plantar fascia in a 48-year-old woman with a low level of physical activity and no history of direct injury to the foot, plantar fasciitis, or steroid injections. © 2017 Wiley Periodicals, Inc.

  12. Torsion of wandering spleen and distal pancreas

    International Nuclear Information System (INIS)

    Sheflin, J.R.; Lee, C.M.; Kretchmar, K.A.

    1984-01-01

    Wandering spleen is the term applied to the condition in which a long pedicle allows the spleen to lie in an abnormal location. Torsion of a wandering spleen is an unusual cause of an acute abdomen and is rarely diagnosed preoperatively. Associated torsion of the distal pancreas is even more uncommon. The authors describe a patient with torsion of a wandering spleen and distal pancreas, who was correctly diagnosed, and define the merits of the imaging methods used. The initial examination should be 99 /sup m/Tc-sulfur colloid liner-spleen scanning

  13. Miniaturized dielectric waveguide filters

    OpenAIRE

    Sandhu, MY; Hunter, IC

    2016-01-01

    Design techniques for a new class of integrated monolithic high-permittivity ceramic waveguide filters are presented. These filters enable a size reduction of 50% compared to air-filled transverse electromagnetic filters with the same unloaded Q-factor. Designs for Chebyshev and asymmetric generalised Chebyshev filter and a diplexer are presented with experimental results for an 1800 MHz Chebyshev filter and a 1700 MHz generalised Chebyshev filter showing excellent agreement with theory.

  14. Endovascular treatment of ruptured distal posterior inferior ...

    African Journals Online (AJOL)

    2014-03-01

    Mar 1, 2014 ... there are lots of reports regarding the interventional therapy of the artery aneurysms (including proximal and distal), all of which are considered to be safe and effective. All the incidences of interventional-related complications are below 10% and there is no report of injury of lower cranial nerves [11, 12].

  15. Urethral mobilization and advancement for distal hypospadias ...

    African Journals Online (AJOL)

    Background/purpose Despite the existence of numerous techniques for the repair of distal penile hypospadias, none of them is completely satisfactory. Advancing the urethra without mobilization for repair of glanular hypospadias has the advantage of avoiding a common problem occurring with other techniques: ...

  16. Multi-Canister overpack internal HEPA filters

    International Nuclear Information System (INIS)

    SMITH, K.E.

    1998-01-01

    The rationale for locating a filter assembly inside each Multi-Canister Overpack (MCO) rather than include the filter in the Cold Vacuum Drying (CVD) process piping system was to eliminate the potential for contamination to the operators, processing equipment, and the MCO. The internal HEPA filters provide essential protection to facility workers from alpha contamination, both external skin contamination and potential internal depositions. Filters installed in the CVD process piping cannot mitigate potential contamination when breaking the process piping connections. Experience with K-Basin material has shown that even an extremely small release can result in personnel contamination and costly schedule disruptions to perform equipment and facility decontamination. Incorporating the filter function internal to the MCO rather than external is consistent with ALARA requirements of 10 CFR 835. Based on the above, the SNF Project position is to retain the internal HEPA filters in the MCO design

  17. Interface stability of granular filter structures under currents

    NARCIS (Netherlands)

    Verheij, H.J.; Hoffmans, G.; Dorst, K.; Van de Sande, S.

    2012-01-01

    Granular filters are used for protection of structures against scour and erosion. For a proper functioning it is necessary that the interfaces between the filter structure, the subsoil and the water flowing above the filter structure are stable. Stability means that there is no transport of subsoil

  18. Selection vector filter framework

    Science.gov (United States)

    Lukac, Rastislav; Plataniotis, Konstantinos N.; Smolka, Bogdan; Venetsanopoulos, Anastasios N.

    2003-10-01

    We provide a unified framework of nonlinear vector techniques outputting the lowest ranked vector. The proposed framework constitutes a generalized filter class for multichannel signal processing. A new class of nonlinear selection filters are based on the robust order-statistic theory and the minimization of the weighted distance function to other input samples. The proposed method can be designed to perform a variety of filtering operations including previously developed filtering techniques such as vector median, basic vector directional filter, directional distance filter, weighted vector median filters and weighted directional filters. A wide range of filtering operations is guaranteed by the filter structure with two independent weight vectors for angular and distance domains of the vector space. In order to adapt the filter parameters to varying signal and noise statistics, we provide also the generalized optimization algorithms taking the advantage of the weighted median filters and the relationship between standard median filter and vector median filter. Thus, we can deal with both statistical and deterministic aspects of the filter design process. It will be shown that the proposed method holds the required properties such as the capability of modelling the underlying system in the application at hand, the robustness with respect to errors in the model of underlying system, the availability of the training procedure and finally, the simplicity of filter representation, analysis, design and implementation. Simulation studies also indicate that the new filters are computationally attractive and have excellent performance in environments corrupted by bit errors and impulsive noise.

  19. Indications, management, and complications of temporary inferior vena cava filters

    International Nuclear Information System (INIS)

    Linsenmaier, Ulrich; Rieger, Johannes; Schenk, Franz; Rock, Clemens; Mangel, Eugen; Pfeifer, Klaus Juergen

    1998-01-01

    Purpose: We describe the results of a preliminary prospective study using different recently developed temporary and retrievable inferior vena cava (IVC) filters.Methods: Fifty temporary IVC filters (Guenther, Guenther Tulip, Antheor) were inserted in 47 patients when the required period of protection against pulmonary embolism (PE) was estimated to be less than 2 weeks. The indications were documented deep vein thrombosis (DVT) and temporary contraindications for anticoagulation, a high risk for PE, and PE despite DVT prophylaxis.Results: Filters were removed 1-12 days after placement and nine (18%) had captured thrombi. Complications were one PE during and after removal of a filter, two minor filter migrations, and one IVC thrombosis.Conclusion: Temporary filters are effective in trapping clots and protecting against PE, and the complication rate does not exceed that of permanent filters. They are an alternative when protection from PE is required temporarily, and should be considered in patients with a normal life expectancy.

  20. Recirculating electric air filter

    Science.gov (United States)

    Bergman, W.

    1985-01-09

    An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

  1. Behavior of HEPA filters under high humidity airflows

    International Nuclear Information System (INIS)

    Ricketts, C.I.

    1992-10-01

    To help determine and improve the safety margins of High Efficiency Particulate Air (HEPA) filter units in nuclear facilities under possible accident conditions, the structural limits and failure mechanisms of filter in high-humidity airflows were established and the fundamental physical phenomena underlying filter failure or malfunction in humid air were identified. Empirical models for increases in filter pressure drop with time in terms of the relevant airstream parameters were also developed. The weaknesses of currently employed humidity countermeasures used in filter protection are discussed and fundamental explanations for reported filter failures in normal service are given. (orig./DG) [de

  2. Passive Power Filters

    CERN Document Server

    Künzi, R.

    2015-06-15

    Power converters require passive low-pass filters which are capable of reducing voltage ripples effectively. In contrast to signal filters, the components of power filters must carry large currents or withstand large voltages, respectively. In this paper, three different suitable filter struc tures for d.c./d.c. power converters with inductive load are introduced. The formulas needed to calculate the filter components are derived step by step and practical examples are given. The behaviour of the three discussed filters is compared by means of the examples. P ractical aspects for the realization of power filters are also discussed.

  3. Filter replacement lifetime prediction

    Science.gov (United States)

    Hamann, Hendrik F.; Klein, Levente I.; Manzer, Dennis G.; Marianno, Fernando J.

    2017-10-25

    Methods and systems for predicting a filter lifetime include building a filter effectiveness history based on contaminant sensor information associated with a filter; determining a rate of filter consumption with a processor based on the filter effectiveness history; and determining a remaining filter lifetime based on the determined rate of filter consumption. Methods and systems for increasing filter economy include measuring contaminants in an internal and an external environment; determining a cost of a corrosion rate increase if unfiltered external air intake is increased for cooling; determining a cost of increased air pressure to filter external air; and if the cost of filtering external air exceeds the cost of the corrosion rate increase, increasing an intake of unfiltered external air.

  4. Distal displacement of the maxilla and the upper first molar.

    Science.gov (United States)

    Baumrind, S; Molthen, R; West, E E; Miller, D M

    1979-06-01

    Data from a sample of 198 Class II cases treated with various appliances which deliver distally directed forces to the maxilla were examined to determine the frequency of absolute distal displacement of the upper first molar and of the maxilla. Analysis revealed that such distal displacement is possible and that it is, in fact, a frequent finding following treatment. Long-range stability of distal displacement was not assessed.

  5. Iodine filters in nuclear installations

    International Nuclear Information System (INIS)

    Wilhelm, J.G.

    1982-01-01

    The present report discusses the significance for environmental exposure of the iodine released with the gaseous effluents of nuclear power stations and reprocessing plants in relation to releases of other airborne radionuclides. Iodine filtration processes are described. The release pathways and the composition of airborne fission product iodine mixtures and their bearing on environmental exposure are discussed on the basis of measured fission product iodine emissions. The sorbents which can be used for iodine filtration, their removal efficiencies and range of applications are dealt with in detail. The particular conditions governing iodine removal, which are determined by the various gaseous iodine species, are illustrated on the basis of experimentally determined retention profiles. Particular attention is given to the limitations imposed by temperature, humidity, radiation and filter poisoning. The types of filter normally used are described, their advantages and drawbacks discussed, the principles underlying their design are outlined and the sources of error indicated. The methods normally applied to test the efficiency of various iodine sorbents are described and assessed. Operating experience with iodine filters, gathered from surveillance periods of many years, is supplemented by a large number of test results and the findings of extensive experiments. Possible ways of prolonging the permissible service lives of iodine filters are discussed and information is given on protective measures. The various iodine removal processes applied in reprocessing plants are described and compared with reference to efficiency and cost. The latest developments in filter technology in reprocessing plants are briefly outlined

  6. Distal radioulnar joint: functional anatomy, including pathomechanics.

    Science.gov (United States)

    Haugstvedt, J R; Langer, M F; Berger, R A

    2017-05-01

    The distal radioulnar joint allows the human to rotate the forearm to place the hand in a desired position to perform different tasks, without interfering with the grasping function of the hand. The ulna is the stable part of the forearm around which the radius rotates; the stability of the distal radioulnar joint is provided by the interaction between ligaments, muscles and bones. The stabilizing structures are the triangular fibrocartilage complex, the ulnocarpal ligament complex, the extensor carpi ulnaris tendon and tendon sheath, the pronator quadratus, the interosseous membrane and ligament, the bone itself and the joint capsule. The purpose of this review article is to present and illustrate the current understanding of the functional anatomy and pathomechanics of this joint.

  7. Optimization of filter loading

    International Nuclear Information System (INIS)

    Turney, J.H.; Gardiner, D.E.; Sacramento Municipal Utility District, Herald, CA)

    1985-01-01

    The introduction of 10 CFR Part 61 has created potential difficulties in the disposal of spent cartridge filters. When this report was prepared, Rancho Seco had no method of packaging and disposing of class B or C filters. This work examined methods to minimize the total operating cost of cartridge filters while maintaining them below the class A limit. It was found that by encapsulating filters in cement the filter operating costs could be minimized

  8. Distal Stressors and Depression among Homeless Men

    OpenAIRE

    Coohey, Carol; Easton, Scott D.

    2016-01-01

    Depression is a common problem among homeless men that may interfere with functional tasks, such as securing stable housing, obtaining employment, and accessing health services. Previous research on depression among homeless men has largely focused on current psychosocial resources, substance abuse, and past victimization. Guided by Ensel and Lin’s life course stress process model, the authors examined whether distal stressors, including victimization and exposure to parent problems in childh...

  9. Fractures of the distal phalanx in the horse

    International Nuclear Information System (INIS)

    Yovich, J.V.

    1989-01-01

    Fractures of the distal phalanx are an important cause of lameness referable to the foot. Depending on the fracture configuration and articular involvement, conservative or surgical treatment may be required. Fractures of the distal phalanx have been divided into six categories based on fracture configuration. Discussion of clinical features, management, and prognosis for horses with distal phalangeal fractures is presented for each fracture type

  10. Nonunions of the distal tibia treated by reamed intramedullary nailing

    NARCIS (Netherlands)

    Richmond, Jeffrey; Colleran, Kevin; Borens, Olivier; Kloen, Peter; Helfet, David L.

    2004-01-01

    The purpose of this study is to determine the efficacy of reamed intramedullary nailing in the treatment of nonunions of the distal one-fourth of the tibia. Nonunions of the distal tibia are particularly difficult to treat given the short distal segment, the proximity to the ankle joint, and the

  11. Management and treatment of distal ulcerative colitis

    Directory of Open Access Journals (Sweden)

    Andrea Calafiore

    2013-12-01

    Full Text Available Ulcerative colitis (UC is a chronic inflammatory condition that is confined to the colonic mucosa. Its main symptoms include diarrhea, rectal bleeding and abdominal pain. Approximately two-thirds of UC patients have disease confined distal to the splenic flexure, which can be treated effectively with topical therapy. This means the active drug can be delivered directly to the site of inflammation, limiting the systemic absorption and potential side effects. Topical treatment with aminosalicylates is the most effective approach in the treatment of these forms, provided that the formulation reaches the upper margin of the disease. Given this, the suppository formulation is the treatment of choice for proctitis and distal sigmoiditis. Thanks to their proximal spread, enemas, foams and gels represent the treatment of choice for proctosigmoiditis and for distal ulcerative colitis. Oral aminosalicylates are less effective than topical therapies in patients with active disease, while the combination of topical and oral treatment is more effective in patients refractory to topical or oral mono-therapy. Topically administered aminosalicylates play an important role in the maintenance of remission, but the long-term adhesion to therapy is poor. For this reason, the oral formulation is the first-line therapy in the maintenance of remission. Refractory patients can be treated with topical steroids or systemic steroids and TNF-alpha inhibitors in severe forms.

  12. Potential for HEPA filter damage from water spray systems in filter plenums

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, W. [Lawrence Livermore National Lab., CA (United States); Fretthold, J.K. [Rocky Flats Safe Sites of Colorado, Golden, CO (United States); Slawski, J.W. [Department of Energy, Germantown, MD (United States)

    1997-08-01

    The water spray systems in high efficiency particulate air (HEPA) filter plenums that are used in nearly all Department of Energy (DOE) facilities for protection against fire was designed under the assumption that the HEPA filters would not be damaged by the water sprays. The most likely scenario for filter damage involves filter plugging by the water spray, followed by the fan blowing out the filter medium. A number of controlled laboratory tests that were previously conducted in the late 1980s are reviewed in this paper to provide a technical basis for the potential HEPA filter damage by the water spray system in HEPA filter plenums. In addition to the laboratory tests, the scenario for BEPA filter damage during fires has also occurred in the field. A fire in a four-stage, BEPA filter plenum at Rocky Flats in 1980 caused the first three stages of BEPA filters to blow out of their housing and the fourth stage to severely bow. Details of this recently declassified fire are presented in this paper. Although these previous findings suggest serious potential problems exist with the current water spray system in filter plenums, additional studies are required to confirm unequivocally that DOE`s critical facilities are at risk. 22 refs., 15 figs.

  13. An Algorithm for the Use of Embolic Protection During Atherectomy for Femoral Popliteal Lesions.

    Science.gov (United States)

    Krishnan, Prakash; Tarricone, Arthur; Purushothaman, K Raman; Purushothaman, Meerarani; Vasquez, Miguel; Kovacic, Jason; Baber, Usman; Kapur, Vishal; Gujja, Karthik; Kini, Annapoorna; Sharma, Samin

    2017-02-27

    This study sought to identify an algorithm for the use of distal embolic protection on the basis of angiographic lesion morphology and vascular anatomy for patients undergoing atherectomy for femoropopliteal lesions. Atherectomy has been shown to create more embolic debris than angioplasty alone. Distal embolic protection has been shown to be efficacious in capturing macroemboli; however, no consensus exists for the appropriate lesions to use distal embolic protection during atherectomy. Patients with symptomatic lower extremity peripheral artery disease treated with atherectomy and distal embolic protection were evaluated to identify potential predictors of DE. Plaque collected from the SilverHawk nose cone subset was sent to pathology for analysis to evaluate the accuracy of angiography in assessing plaque morphology. Significant differences were found in lesion length (142.1 ± 62.98 vs. 56.91 ± 41.04; p = 0.0001), low-density lipoprotein (82.3 ± 40.3 vs. 70.9 ± 23.2; p = 0.0006), vessel runoff (1.18 ± 0.9 vs. 1.8 ± 0.9; p = 0.0001), chronic total occlusion (131 vs. 10; p = 0.001), in-stent restenosis (33 vs. 6; p = 0.0081), and calcified lesions (136 vs. 65; p 40 mm, and atherosclerotic lesions >140 mm identified by peripheral angiography necessitate concomitant filter use during atherectomy to prevent embolic complications. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Maxillary molar distalization with the dual-force distalizer supported by mini-implants: a clinical study.

    Science.gov (United States)

    Oberti, Giovanni; Villegas, Carlos; Ealo, Martha; Palacio, John Camilo; Baccetti, Tiziano

    2009-03-01

    The objective of this prospective study was to describe the clinical effects of a bone-supported molar distalizing appliance, the dual-force distalizer. The study group included 16 patients (mean age, 14.3 years) with Class II molar relationships. Study models and lateral cephalograms were taken before and after the distalizing movement to record significant dental and skeletal changes (Wilcoxon test). The average distalization time was 5 months, with a movement rate of 1.2 mm per month; the distalization amounts were 5.9 +/- 1.72 mm at the crown level and 4.4 +/- 1.41 mm at the furcation level. The average molar inclination was 5.6 degrees +/- 3.7 degrees ; this was less than the amount of inclination generated by bone-supported appliances that use single distalizing forces. The correlation between inclination and distalization was not significant, indicating predominantly bodily movement. The teeth anterior to the first molar moved distally also; the second premolars distalized an average of 4.26 mm, and the incisors retruded by 0.53 mm. The dual-force distalizer is a valid alternative distalizing appliance that generates controlled molar distalization with a good rate of movement and no loss of anchorage.

  15. Robotic distal pancreatectomy versus conventional laparoscopic distal pancreatectomy: a comparative study for short-term outcomes.

    Science.gov (United States)

    Lai, Eric C H; Tang, Chung Ngai

    2015-09-01

    Robotic system has been increasingly used in pancreatectomy. However, the effectiveness of this method remains uncertain. This study compared the surgical outcomes between robot-assisted laparoscopic distal pancreatectomy and conventional laparoscopic distal pancreatectomy. During a 15-year period, 35 patients underwent minimally invasive approach of distal pancreatectomy in our center. Seventeen of these patients had robot-assisted laparoscopic approach, and the remaining 18 had conventional laparoscopic approach. Their operative parameters and perioperative outcomes were analyzed retrospectively in a prospective database. The mean operating time in the robotic group (221.4 min) was significantly longer than that in the laparoscopic group (173.6 min) (P = 0.026). Both robotic and conventional laparoscopic groups presented no significant difference in spleen-preservation rate (52.9% vs. 38.9%) (P = 0.505), operative blood loss (100.3 ml vs. 268.3 ml) (P = 0.29), overall morbidity rate (47.1% vs. 38.9%) (P = 0.73), and post-operative hospital stay (11.4 days vs. 14.2 days) (P = 0.46). Both groups also showed no perioperative mortality. Similar outcomes were observed in robotic distal pancreatectomy and conventional laparoscopic approach. However, robotic approach tended to have the advantages of less blood loss and shorter hospital stay. Further studies are necessary to determine the clinical position of robotic distal pancreatectomy.

  16. An innovative technique to distalize maxillary molar using microimplant supported rapid molar distalizer

    Directory of Open Access Journals (Sweden)

    Meenu Goel

    2013-01-01

    Full Text Available Introduction: In recent years, enhancements in implants have made their use possible as a mode of absolute anchorage in orthodontic patients. In this paper, the authors have introduced an innovative technique to unilaterally distalize the upper left 1 st molar to obtain an ideal Class I molar relationship from a Class II existing molar relationship with an indigenous designed distalizer. Clinical Innovation: For effective unilateral diatalization of molar, a novel cantilever sliding jig assembly was utilized with coil spring supported by a buccally placed single micro implant. The results showed 3 mm of bodily distalization with 1 mm of intrusion and 2° of distal tipping of upper left 1 st molar in 1.5 months. Discussion: This appliance is relatively easy to insert, well-tolerated, and requires minimal patient cooperation compared to other present techniques of molar distalization. Moreover, it is particularly useful in cases that are Class II on one side and Class I on the other, with a minor midline discrepancy and nominal overjet. Patient acceptance level was reported to be within patients physiological and comfort limits.

  17. Laboratory for filter testing

    Energy Technology Data Exchange (ETDEWEB)

    Paluch, W.

    1987-07-01

    Filters used for mine draining in brown coal surface mines are tested by the Mine Draining Department of Poltegor. Laboratory tests of new types of filters developed by Poltegor are analyzed. Two types of tests are used: tests of scale filter models and tests of experimental units of new filters. Design and operation of the test stands used for testing mechanical properties and hydraulic properties of filters for coal mines are described: dimensions, pressure fluctuations, hydraulic equipment. Examples of testing large-diameter filters for brown coal mines are discussed.

  18. [New anterolateral approach of distal femur for treatment of distal femoral fractures].

    Science.gov (United States)

    Zhang, Bin; Dai, Min; Zou, Fan; Luo, Song; Li, Binhua; Qiu, Ping; Nie, Tao

    2013-11-01

    To assess the effectiveness of the new anterolateral approach of the distal femur for the treatment of distal femoral fractures. Between July 2007 and December 2009, 58 patients with distal femoral fractures were treated by new anterolateral approach of the distal femur in 28 patients (new approach group) and by conventional approach in 30 patients (conventional approach group). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, disease duration, complication, or preoperative intervention (P > 0.05). The operation time, intraoperative blood loss, intraoperative fluoroscopy frequency, hospitalization days, and Hospital for Special Surgery (HSS) score of knee were recorded. Operation was successfully completed in all patients of 2 groups, and healing of incision by first intention was obtained; no vascular and nerves injuries occurred. The operation time and intraoperative fluoroscopy frequency of new approach group were significantly less than those of conventional approach group (P 0.05). All patients were followed up 12-36 months (mean, 19.8 months). Bone union was shown on X-ray films; the fracture healing time was (12.62 +/- 2.34) weeks in the new approach group and was (13.78 +/- 1.94) weeks in the conventional approach group, showing no significant difference (t=2.78, P=0.10). The knee HSS score at last follow-up was 94.4 +/- 4.2 in the new approach group, and was 89.2 +/- 6.0 in the conventional approach group, showing significant difference between 2 groups (t=3.85, P=0.00). New anterolateral approach of the distal femur for distal femoral fractures has the advantages of exposure plenitude, minimal tissue trauma, and early function rehabilitation training so as to enhance the function recovery of knee joint.

  19. Is there any evidence that cerebral protection is beneficial? Experimental data.

    Science.gov (United States)

    Macdonald, S

    2006-04-01

    This article presents the available experimental data from the world literature on the use of cerebral protection devices during carotid artery stenting (CAS). Clinical studies relying on surrogate markers of cerebral embolisation in place of neurological event rate as primary outcome measures are evaluated alongside bench-top and animal studies. These surrogate markers include evaluations of outcomes using procedural transcranial Doppler (TCD) and diffusion-weighted magnetic resonance imaging of brain (DWI). Pathological analyses of debris retrieved from in-vivo analyses of protection devices are also included in this review because although the focus of these studies was primarily clinical, the laboratory data will be preferentially presented and it provides interesting insights. It can be shown that each of the three philosophies of cerebral protection, namely flow arrest (proximal or distal), flow reversal and distal filtration is capable of the entrapment of sizeable debris that would logically threaten devastating stroke if it embolized to the brain. Whilst balloon occlusion significantly reduces the procedural microembolic load (particles less than 60 mm) and flow reversal may be the first means to entirely eliminate it, filters may be associated with increased microembolization. This has been described by some workers as controlled embolization. Certainly, particles smaller than the pore size of currently available filters (60-140 mm) will readily evade capture due to filter periflow and through-flow. There is evidence to suggest that tens of thousands of particles of this size may be released during CAS and there is some evidence that this may be associated with more new white lesions on DWI of brain. The clinical consequences of this controlled embolization however, remain unclear and sophisticated neuropsychometric test batteries may need to be applied at later time points to detect subtle injury that may be compounded by a late inflammatory response

  20. Mini-implant-supported Molar Distalization

    Directory of Open Access Journals (Sweden)

    Amit Goyal

    2012-01-01

    Full Text Available Temporary anchorage devices popularly called mini-implants or miniscrews are the latest addition to an orthodontist′s armamentarium. The following case report describes the treatment of a 16-year-old girl with a pleasant profile, moderate crowding and Angle′s Class II molar relationship. Maxillary molar distalization was planned and mini-implants were used to preserve the anterior anchorage. After 13 months of treatment, Class I molar and canine relation was achieved bilaterally and there was no anterior proclination. Thus, mini-implants provide a viable option to the clinician to carry out difficult tooth movements without any side effects.

  1. Periosteal osteoblastoma of the distal femur

    Energy Technology Data Exchange (ETDEWEB)

    Nakatani, Tetsuya; Yamamoto, Tetsuji; Akisue, Toshihiro; Marui, Takashi; Hitora, Toshiaki; Kawamoto, Teruya; Nagira, Keiko; Yoshiya, Shinichi; Kurosaka, Masahiro [Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe (Japan); Fujita, Ikuo; Matsumoto, Keiji [Department of Orthopaedic Surgery, Hyogo Medical Center for Adults, Akashi, Hyogo (Japan)

    2004-02-01

    Osteoblastomas located on the surface of the cortical bone, so-called periosteal osteoblastomas, are extremely rare. We report on a case of periosteal osteoblastoma arising from the posterior surface of the right distal femur in a 17-year-old man. Roentgenographic, computed tomographic, magnetic resonance imaging, and histologic features of the case are presented. Periosteal osteoblastoma should be radiologically and histologically differentiated from myositis ossificans, avulsive cortical irregularity syndrome, osteoid osteoma, parosteal osteosarcoma, periosteal osteosarcoma, and high-grade surface osteosarcoma. Although periosteal osteoblastoma is rare, this tumor should be included in the differential diagnosis of surface-type bone tumors. (orig.)

  2. Bias aware Kalman filters

    DEFF Research Database (Denmark)

    Drecourt, J.-P.; Madsen, H.; Rosbjerg, Dan

    2006-01-01

    This paper reviews two different approaches that have been proposed to tackle the problems of model bias with the Kalman filter: the use of a colored noise model and the implementation of a separate bias filter. Both filters are implemented with and without feedback of the bias into the model state....... The colored noise filter formulation is extended to correct both time correlated and uncorrelated model error components. A more stable version of the separate filter without feedback is presented. The filters are implemented in an ensemble framework using Latin hypercube sampling. The techniques...... are illustrated on a simple one-dimensional groundwater problem. The results show that the presented filters outperform the standard Kalman filter and that the implementations with bias feedback work in more general conditions than the implementations without feedback. 2005 Elsevier Ltd. All rights reserved....

  3. Simon-nitinol filter

    International Nuclear Information System (INIS)

    Simon, M.; Kim, D.; Porter, D.H.; Kleshinski, S.

    1989-01-01

    This paper discusses a filter that exploits the thermal shape-memory properties of the nitinol alloy to achieve an optimized filter shape and a fine-bore introducer. Experimental methods and materials are given and results are analyzed

  4. Guenther tulip retrievable filter: why, when and how?

    International Nuclear Information System (INIS)

    Millward, S.F.

    2001-01-01

    Nonpermanent inferior vena cava (IVC) filters can be subdivided into temporary and retrievable filters. Temporary filters are attached to a catheter or guide wire. They have been extensively used in Europe, mainly for the prevention of pulmonary embolism (PE) during thrombolytic treatment for lower extremity deep vein thrombosis (DVT). However, the reported rate of recurrent PE in patients protected with a temporary filter appears to be similar, or even higher, than that seen in North American studies of thrombolytic treatment of DVT when no filter was used. Results obtained with temporary filters in other clinical situations have also been somewhat discouraging. Consequently, research efforts in North America with nonpermanent filters appear to have shifted predominantly to the study of retrievable filters. Retrievable filters, such as the Guenther Tulip filter (William Cook Europe, Bjaeverskov, Denmark) (Fig. 1), are permanent filters with a design feature (usually a hook that can be snared) to permit retrieval. They have an advantage over temporary filters in that they can be either left in place permanently or retrieved, whichever is most appropriate for a given patient. The Guenther Tulip filter is currently the only approved device from this versatile new class of retrievable filters. ln this article, I hope to offer some practical points on why, when and how the device should be used. (author)

  5. Distal anastomotic vein adjunct usage in infrainguinal prosthetic bypasses.

    Science.gov (United States)

    McPhee, James T; Goodney, Philip P; Schanzer, Andres; Shaykevich, Shimon; Belkin, Michael; Menard, Matthew T

    2013-04-01

    ). The DVA group had a higher rate of completion angiogram performed (55.7% vs 37.5%; P =.002) and were more likely to be discharged on coumadin (53.4% vs 37.1%; P =.01). By multivariable analysis, use of a distal DVA was protective against MALEs (hazard ratio, 0.36; 95% confidence interval, 0.14-0.90; P = .03). This contemporary multi-institutional propensity-matched study demonstrates that patients that receive distal anastomotic vein adjuncts as part of infrainguinal prosthetic bypass operations in general have more extreme comorbidities and more technically challenging operations based on level of target vessel and prior bypass attempts. After propensity-matched analysis, the use of a DVA may protect against MALEs in prosthetic bypass surgery and should be considered when feasible. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  6. MST Filterability Tests

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, M. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Burket, P. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Duignan, M. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-03-12

    The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). The low filter flux through the ARP has limited the rate at which radioactive liquid waste can be treated. Recent filter flux has averaged approximately 5 gallons per minute (gpm). Salt Batch 6 has had a lower processing rate and required frequent filter cleaning. Savannah River Remediation (SRR) has a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. In addition, at the time the testing started, SRR was assessing the impact of replacing the 0.1 micron filter with a 0.5 micron filter. This report describes testing of MST filterability to investigate the impact of filter pore size and MST particle size on filter flux and testing of filter enhancers to attempt to increase filter flux. The authors constructed a laboratory-scale crossflow filter apparatus with two crossflow filters operating in parallel. One filter was a 0.1 micron Mott sintered SS filter and the other was a 0.5 micron Mott sintered SS filter. The authors also constructed a dead-end filtration apparatus to conduct screening tests with potential filter aids and body feeds, referred to as filter enhancers. The original baseline for ARP was 5.6 M sodium salt solution with a free hydroxide concentration of approximately 1.7 M.3 ARP has been operating with a sodium concentration of approximately 6.4 M and a free hydroxide concentration of approximately 2.5 M. SRNL conducted tests varying the concentration of sodium and free hydroxide to determine whether those changes had a significant effect on filter flux. The feed slurries for the MST filterability tests were composed of simple salts (NaOH, NaNO2, and NaNO3) and MST (0.2 – 4.8 g/L). The feed slurry for the filter enhancer tests contained simulated salt batch 6 supernate, MST, and filter enhancers.

  7. Radiographic anatomy of the distal dural SAC

    International Nuclear Information System (INIS)

    Larsen, J.L.; Olsen, K.O.

    1991-01-01

    A radio-anatomical study was performed of the distal dural sac (DS) in 121 patients subjected to myelography. In 83.4% the termination of the DS was located from the upper half of the S1-segment to the lower half of the S2-segment. In the remaining patients the dural terminations were more distally located. The average location of the DS-termination was higher than that found in a previous anatomic study. The inference is that in patients with low-back pain and sciatica, the DS tends to terminate at a higher spinal level than in a non-selected anatomic material. The caudal reduction in sagittal diameter of the DS was less than that of the frontal diameter of the sac. The linear diminution in cross-sectional area of the DS from the level of L3 towards the lumbosacral junction was not correlated with the degree of caudal extension of the DS into the sacrum. Thus the length of the DS and its transverse diameters are independent of each other. These results supported the view that the location of the termination of the DS (and hence that of the spinal cord) is not related to stenosis of the central spinal canal. (orig.)

  8. Maxillary molar distalization with first class appliance.

    Science.gov (United States)

    Ramesh, Namitha; Palukunnu, Biswas; Ravindran, Nidhi; Nair, Preeti P

    2014-02-27

    Non-extraction treatment has gained popularity for corrections of mild-to-moderate class II malocclusion over the past few decades. The distalization of maxillary molars is of significant value for treatment of cases with minimal arch discrepancy and mild class II molar relation associated with a normal mandibular arch and acceptable profile. This paper describes our experience with a 16-year-old female patient who reported with irregularly placed upper front teeth and unpleasant smile. The patient was diagnosed to have angles class II malocclusion with moderate maxillary anterior crowding, deep bite of 4 mm on a skeletal class II base with an orthognathic maxilla and retrognathic mandible and normal growth pattern. She presented an ideal profile and so molar distalization was planned with the first-class appliance. Molars were distalised by 8 mm on the right and left quadrants and class I molar relation achieved within 4 months. The space gained was utilised effectively to align the arch and establish a class I molar and canine relation.

  9. Dermal pocketing following distal finger replantation.

    Science.gov (United States)

    Puhaindran, Mark E; Paavilainen, Pasi; Tan, David M K; Peng, Yeong Pin; Lim, Aymeric Y T

    2010-08-01

    Replantation is an ideal technique for reconstruction following fingertip amputation as it provides 'like for like' total reconstruction of the nail complex, bone pulp tissue and skin with no donor-site morbidity. However, fingertips are often not replanted because veins cannot be found or are thought to be too small to repair. Attempts at 'cap-plasty' or pocketing of replanted tips with and without microvascular anastomosis have been done in the past with varying degrees of success. We prospectively followed up a group of patients who underwent digital replantation and dermal pocketing in the palm to evaluate the outcome of this procedure. There were 10 patients with 14 amputated digits (two thumbs, five index, four middle, two ring and one little) who underwent dermal pocketing of the amputated digit following replantation. Among the 14 digits that were treated with dermal pocketing, 11 survived completely, one had partial atrophy and two were completely lost. Complications encountered included finger stiffness (two patients) and infection of the replanted fingertip with osteomyelitis of the distal phalanx (one patient). We believe that this technique can help increase the chance of survival for distal replantation with an acceptable salvage rate of 85% in our series. Copyright 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Osteoid osteoma of the distal clavicle

    Directory of Open Access Journals (Sweden)

    Bernardo Barcellos Terra

    Full Text Available ABSTRACT The osteoid osteoma is a bone tumor that accounts for 10% of benign tumors. It was described in 1935 by Jaffe, as a tumor that affects the young adult population, with a predominance of males. This study aims to present a case of late diagnosis of a patient with osteoid osteoma of the distal clavicle region. Female patient, 44 years old, non-professional volleyball player, reported pain in the anterior and superior region of the shoulder girdle, specifically in the acromioclavicular joint, which worsened at night and had been treated for nine months as tendinitis of the rotator cuff and acromioclavicular joint arthritis. After confirming the diagnosis, the patient underwent open surgery with resection of the distal clavicle. At two years of follow-up, the patient presents without local pain. In the radiographic evaluation, coracoclavicular distance is preserved and there are no signs of recurrence. Tumors of the shoulder girdle are rare and are often diagnosed late. A high degree of suspicion for the diagnosis of tumors of the shoulder girdle is needed in order to avoid late diagnosis.

  11. Biotin absorption by distal rat intestine

    International Nuclear Information System (INIS)

    Bowman, B.B.; Rosenberg, I.H.

    1987-01-01

    We used the in vivo intestinal loop approach, with short (10-min) and long (3-h) incubations, to examine biotin absorption in proximal jejunum, distal ileum, cecum and proximal colon. In short-term studies, luminal biotin disappearance from rat ileum was about half that observed in the jejunum, whereas absorption by proximal colon was about 12% of that in the jejunum. In 3-h closed-loop studies, the absorption of 1.0 microM biotin varied regionally. Biotin absorption was nearly complete in the small intestine after 3 h; however, only about 15% of the dose had been absorbed in the cecum and 27% in the proximal colon after 3 h. Independent of site of administration, the major fraction of absorbed biotin was recovered in the liver; measurable amounts of radioactive biotin were also present in kidney and plasma. The results support the potential nutritional significance for the rat of biotin synthesized by bacteria in the distal intestine, by demonstrating directly an absorptive capability of mammalian large bowel for this vitamin

  12. [Distal ureteral lithiasis. ESWL versus ambulatory URS].

    Science.gov (United States)

    Miján Ortiz, J L; Gutiérrez Tejero, F; López Carmona, F; Nogueras Ocaña, M; Arrabal Martín, M; Zuluaga Gómez, A

    2001-11-01

    To present the results achieved in the treatment of 1802 distal ureteral stones treated at the Lithotripsy Unit of the San Cecilio University Hospital over the last 10 years (1990-2000). Stones were treated by extracorporeal shock wave lithotripsy (ESWL) or ureteroscopy (URS). ESWL was the initial treatment in 81% of the cases (1460 calculi) and URS in the remaining 19% (342 stones). URS was performed for complication or failed ESWL (102 stones) and ESWL was performed for failed URS, basically due to stone migration (24 stones). Ureterolithotomy was required on 7 occasions. Sedation-analgesia with fentanyl and midazolam was routinely used in URS. Sedation was required in only 55% of the ESWL procedures. Elective ESWL resolved 93% of the cases, a percentage which is similar to that achieved with URS as first treatment. The ESWL retreatment rate was 1.3. URS was successful in 98% of the cases of failed ESWL. There are two treatment modalities for stones in the distal ureter: ESWL and URS. We advocate the use of outpatient URS with sedation preferably in the female patient, impacted stones, obstructive uropathy, stones larger than 2 cm and radiotransparent stones.

  13. 40 CFR 141.560 - Is my system subject to individual filter turbidity requirements?

    Science.gov (United States)

    2010-07-01

    ... filter turbidity requirements? 141.560 Section 141.560 Protection of Environment ENVIRONMENTAL PROTECTION... Filtration and Disinfection-Systems Serving Fewer Than 10,000 People Individual Filter Turbidity Requirements § 141.560 Is my system subject to individual filter turbidity requirements? If your system is a subpart...

  14. A STUDY OF SURGICAL MANAGEMENT OF DISTAL FEMORAL FRACTURES BY DISTAL FEMORAL LOCKING COMPRESSION PLATE OSTEOSYNTHESIS

    Directory of Open Access Journals (Sweden)

    Dema Rajaiah

    2016-08-01

    Full Text Available AIMS AND OBJECTIVES To study the fractures of distal end of femur and the mechanism of injury in distal end femur fractures, the advantages and disadvantages of open reduction and internal fixation of distal end femur fractures by distal femoral locking compression plate osteosynthesis and to analyse the outcome in terms of range of Knee motion, time to union, and limb shortening. RESULTS The mean age of patient is 44 years, 85% are males, road traffic accidents account for majority (80%, right side involved in 70%, Muller’s type C fracture is common, good range of movements is seen 90% of cases and union occurred in 95% in 5 months. The results were assessed using Neer’s score, seven (35% patients had excellent results, eight (40% patients had good results, four (20% patients had fair results and one (5% patient had poor result. CONCLUSION From our study, we conclude that DF-LCP is a safe and reliable implant and has shown excellent to satisfactory results in majority of intra-articular fractures (AO type C. Fixation with locking compression plate showed more effectiveness in severely osteoporotic bones, shorter operative stay, faster recovery, faster union rates and excellent functional outcome.

  15. Rotationally invariant correlation filtering

    International Nuclear Information System (INIS)

    Schils, G.F.; Sweeney, D.W.

    1985-01-01

    A method is presented for analyzing and designing optical correlation filters that have tailored rotational invariance properties. The concept of a correlation of an image with a rotation of itself is introduced. A unified theory of rotation-invariant filtering is then formulated. The unified approach describes matched filters (with no rotation invariance) and circular-harmonic filters (with full rotation invariance) as special cases. The continuum of intermediate cases is described in terms of a cyclic convolution operation over angle. The angular filtering approach allows an exact choice for the continuous trade-off between loss of the correlation energy (or specificity regarding the image) and the amount of rotational invariance desired

  16. The anatomy and physiology of the suspensory apparatus of the distal phalanx.

    Science.gov (United States)

    Pollitt, Christopher C

    2010-04-01

    The equine hoof capsule protects the softer, more sensitive, structures within. Failure of the connection between hoof and bone (suspensory apparatus of the distal phalanx or SADP) results in the crippling lameness of laminitis. Active basal cell proliferation occurs principally in tubular hoof and proximal and distal lamellae. The remaining lamellae are virtually non-proliferative and the hoof wall moves past the stationary distal phalanx, by controlled activation and inhibition of constituent proteases. The lamellar corium derives most of its blood supply from the branches of the terminal arch which perforate the distal phalanx. Valveless veins within the foot can be exploited clinically for retrograde venous therapy or contrast radiography (venography). The basement membrane (BM) forms the interface between the lamellar epidermis and the adjacent dermis and the plasma membrane of each lamellar basal cell is attached to the BM by numerous electron dense adhesion plaques or hemidesmosomes the ultimate attachment unit of the SADP. Laminitis destroys and dislocates the BM and its components and without an intact, functional BM, the structure and function of the lamellar epidermis is pathologically compromised. Transcription and activation of constituent proteases occurs in normal hoof lamellae but in increased amounts during laminitis. Copyright 2010 Elsevier Inc. All rights reserved.

  17. Retina-Inspired Filter.

    Science.gov (United States)

    Doutsi, Effrosyni; Fillatre, Lionel; Antonini, Marc; Gaulmin, Julien

    2018-07-01

    This paper introduces a novel filter, which is inspired by the human retina. The human retina consists of three different layers: the Outer Plexiform Layer (OPL), the inner plexiform layer, and the ganglionic layer. Our inspiration is the linear transform which takes place in the OPL and has been mathematically described by the neuroscientific model "virtual retina." This model is the cornerstone to derive the non-separable spatio-temporal OPL retina-inspired filter, briefly renamed retina-inspired filter, studied in this paper. This filter is connected to the dynamic behavior of the retina, which enables the retina to increase the sharpness of the visual stimulus during filtering before its transmission to the brain. We establish that this retina-inspired transform forms a group of spatio-temporal Weighted Difference of Gaussian (WDoG) filters when it is applied to a still image visible for a given time. We analyze the spatial frequency bandwidth of the retina-inspired filter with respect to time. It is shown that the WDoG spectrum varies from a lowpass filter to a bandpass filter. Therefore, while time increases, the retina-inspired filter enables to extract different kinds of information from the input image. Finally, we discuss the benefits of using the retina-inspired filter in image processing applications such as edge detection and compression.

  18. The intractable cigarette ‘filter problem’

    Science.gov (United States)

    2011-01-01

    Background When lung cancer fears emerged in the 1950s, cigarette companies initiated a shift in cigarette design from unfiltered to filtered cigarettes. Both the ineffectiveness of cigarette filters and the tobacco industry's misleading marketing of the benefits of filtered cigarettes have been well documented. However, during the 1950s and 1960s, American cigarette companies spent millions of dollars to solve what the industry identified as the ‘filter problem’. These extensive filter research and development efforts suggest a phase of genuine optimism among cigarette designers that cigarette filters could be engineered to mitigate the health hazards of smoking. Objective This paper explores the early history of cigarette filter research and development in order to elucidate why and when seemingly sincere filter engineering efforts devolved into manipulations in cigarette design to sustain cigarette marketing and mitigate consumers' concerns about the health consequences of smoking. Methods Relevant word and phrase searches were conducted in the Legacy Tobacco Documents Library online database, Google Patents, and media and medical databases including ProQuest, JSTOR, Medline and PubMed. Results 13 tobacco industry documents were identified that track prominent developments involved in what the industry referred to as the ‘filter problem’. These reveal a period of intense focus on the ‘filter problem’ that persisted from the mid-1950s to the mid-1960s, featuring collaborations between cigarette producers and large American chemical and textile companies to develop effective filters. In addition, the documents reveal how cigarette filter researchers' growing scientific knowledge of smoke chemistry led to increasing recognition that filters were unlikely to offer significant health protection. One of the primary concerns of cigarette producers was to design cigarette filters that could be economically incorporated into the massive scale of cigarette

  19. Study of different filters

    International Nuclear Information System (INIS)

    Cochinal, R.; Rouby, R.

    1959-01-01

    This note first contains a terminology related to filters and to their operation, and then proposes an overview of general characteristics of filters such as load loss with respect to gas rate, efficiency, and clogging with respect to filter pollution. It also indicates standard aerosols which are generally used, how they are dosed, and how efficiency is determined with a standard aerosol. Then, after a presentation of the filtration principle, this note reports the study of several filters: glass wool, filter papers provided by different companies, Teflon foam, English filters, Teflon wool, sintered Teflonite, quartz wool, polyvinyl chloride foam, synthetic filter, sintered bronze. The third part reports the study of some aerosol and dust separators

  20. Changing ventilation filters

    International Nuclear Information System (INIS)

    Hackney, S.

    1980-01-01

    A filter changing unit has a door which interlocks with the door of a filter chamber so as to prevent contamination of the outer surfaces of the doors by radioactive material collected on the filter element and a movable support which enables a filter chamber thereonto to be stored within the unit in such a way that the doors of the unit and the filter chamber can be replaced. The door pivots and interlocks with another door by means of a bolt, a seal around the periphery lip of the first door engages the periphery of the second door to seal the gap. A support pivots into a lower filter element storage position. Inspection windows and glove ports are provided. The unit is releasably connected to the filter chamber by bolts engaging in a flange provided around an opening. (author)

  1. Balanced microwave filters

    CERN Document Server

    Hong, Jiasheng; Medina, Francisco; Martiacuten, Ferran

    2018-01-01

    This book presents and discusses strategies for the design and implementation of common-mode suppressed balanced microwave filters, including, narrowband, wideband, and ultra-wideband filters This book examines differential-mode, or balanced, microwave filters by discussing several implementations of practical realizations of these passive components. Topics covered include selective mode suppression, designs based on distributed and semi-lumped approaches, multilayer technologies, defect ground structures, coupled resonators, metamaterials, interference techniques, and substrate integrated waveguides, among others. Divided into five parts, Balanced Microwave Filters begins with an introduction that presents the fundamentals of balanced lines, circuits, and networks. Part 2 covers balanced transmission lines with common-mode noise suppression, including several types of common-mode filters and the application of such filters to enhance common-mode suppression in balanced bandpass filters. Next, Part 3 exa...

  2. Distal Communication by Chimpanzees (Pan troglodytes): Evidence for Common Ground?

    Science.gov (United States)

    Leavens, David A; Reamer, Lisa A; Mareno, Mary Catherine; Russell, Jamie L; Wilson, Daniel; Schapiro, Steven J; Hopkins, William D

    2015-01-01

    van der Goot et al. (2014) proposed that distal, deictic communication indexed the appreciation of the psychological state of a common ground between a signaler and a receiver. In their study, great apes did not signal distally, which they construed as evidence for the human uniqueness of a sense of common ground. This study exposed 166 chimpanzees to food and an experimenter, at an angular displacement, to ask, "Do chimpanzees display distal communication?" Apes were categorized as (a) proximal or (b) distal signalers on each of four trials. The number of chimpanzees who communicated proximally did not statistically differ from the number who signaled distally. Therefore, contrary to the claim by van der Goot et al., apes do communicate distally. © 2015 The Authors. Child Development © 2015 Society for Research in Child Development, Inc.

  3. Distal renal tubular acidosis and hepatic lipidosis in a cat.

    Science.gov (United States)

    Brown, S A; Spyridakis, L K; Crowell, W A

    1986-11-15

    Clinical and laboratory evidence of hepatic failure was found in a chronically anorectic cat. Simultaneous blood and urine pH determinations established a diagnosis of distal renal tubular acidosis. The cat did not respond to treatment. Necropsy revealed distal tubular nephrosis and hepatic lipidosis. The finding of distal renal tubular acidosis in a cat with hepatic lipidosis emphasizes the importance of complete evaluation of acid-base disorders in patients.

  4. Post-transplant distal limb syndrome

    Directory of Open Access Journals (Sweden)

    María Florencia Borghi Torzillo

    2017-02-01

    Full Text Available The post-transplant distal limb syndrome is a not well known entity, with a prevalence of 5% in patients with renal transplant. Its diagnosis is based on clinical symptoms, bone scintigraphy and MRI, it has a benign course and the patient recovers without sequel. We present the case of a 37-year-old male, with medical history of hypertension, Berger's disease in 1999 that required dialysis three times a week for four years (2009-2013 and renal transplant in 2013. The patient consults on January 2014 referring severe pain in both feet, with sudden onset; he remembers the exact date of the beginning of the pain and denies trauma, pain prevents ambulation. The bone scintigraphy shows pathological uptake in both feet with no difference between the two. Although there is no treatment for this disease, it has a benign course

  5. Filter material charging apparatus for filter assembly for radioactive contaminants

    International Nuclear Information System (INIS)

    Goldsmith, J.M.; O'Nan, A. Jr.

    1977-01-01

    A filter charging apparatus for a filter assembly is described. The filter assembly includes a housing with at least one filter bed therein and the filter charging apparatus for adding filter material to the filter assembly includes a tank with an opening therein, the tank opening being disposed in flow communication with opposed first and second conduit means, the first conduit means being in flow communication with the filter assembly housing and the second conduit means being in flow communication with a blower means. Upon activation of the blower means, the blower means pneumatically conveys the filter material from the tank to the filter housing

  6. Comparison of standard laparoscopic distal pancreatectomy with minimally invasive distal pancreatectomy using the da Vinci S system.

    Science.gov (United States)

    Ito, Masahiro; Asano, Yukio; Shimizu, Tomohiro; Uyama, Ichiro; Horiguchi, Akihiko

    2014-01-01

    Minimally invasive procedures for pancreatic pathologies are increasingly being used, including distal pancreatectomy. This study aimed to assess the indications for and outcomes of the da Vinci distal pancreatectomy procedure. We reviewed the medical records of patients who underwent pancreatic head resection from April 2009 to September 2013. Four patients (mean age, 52.7 years) underwent da Vinci distal pancreatectomy and 10 (mean age, 68.0 +/- 12.1 years) underwent laparoscopic distal pancreatectomy. The mean surgical duration was 292 +/- 153 min and 306 +/- 29 min, the mean blood loss was 153 +/- 71 mL and 61.7 +/- 72 mL, and the mean postoperative length of stay was 24 +/- 11 days and 14 +/- 3 days in the da Vinci distal pancreatectomy and laparoscopic distal pancreatectomy groups, respectively. One patient who underwent da Vinci distal pancreatectomy developed a pancreatic fistula, while 2 patients in the laparoscopic distal pancreatectomy group developed splenic ischemia and gastric torsion, respectively. Laparoscopic and robotic pancreatic resection were both safe and feasible in selected patients with distal pancreatic pathologies. Further studies are necessary to clarify the role of robotic surgery in the advanced laparoscopic era.

  7. [Comparison of laparoscopic distal pancreatectomy and open distal pancreatectomy in pancreatic ductal adenocarcinoma].

    Science.gov (United States)

    Xu, K; Su, J J; Su, M; Yan, L; Feng, J; Xin, X L; Chen, Y L

    2017-10-23

    Objective: To compare and evaluate the curative effect of laparoscopic distal pancreatectomy(LDP) and traditional open distal pancreatectomy(ODP) in pancreatic ductal adenocarcinoma. Methods: The clinical data of 15 patients treated by LDP and 87 contemporaneous cases treated by ODP from January 2010 to November 2015 was collected, and the curative effect and prognosis of these patients were retrospectively analyzed. Results: The operation time of LDP group was (286.5±48.1) min, significantly longer than that of OPD group(226.6±56.8) min ( P 0.05). In both LDP group and ODP group, none occurred percutaneous drainage, re-admissions, second operation or perioperative death. Conclusions: Compared to ODP, LDP is much safer and more steady in perioperative periodand operation. Patients of pancreatic ductal adenocarcinoma received LDP can acquire more benefit and recovery sooner, and LDP is a safe and effective operative method.

  8. Concentric Split Flow Filter

    Science.gov (United States)

    Stapleton, Thomas J. (Inventor)

    2015-01-01

    A concentric split flow filter may be configured to remove odor and/or bacteria from pumped air used to collect urine and fecal waste products. For instance, filter may be designed to effectively fill the volume that was previously considered wasted surrounding the transport tube of a waste management system. The concentric split flow filter may be configured to split the air flow, with substantially half of the air flow to be treated traveling through a first bed of filter media and substantially the other half of the air flow to be treated traveling through the second bed of filter media. This split flow design reduces the air velocity by 50%. In this way, the pressure drop of filter may be reduced by as much as a factor of 4 as compare to the conventional design.

  9. Early control of distal internal carotid artery during carotid endarterectomy: does it reduce cerebral microemboli?

    Science.gov (United States)

    Mommertz, G; Das, M; Langer, S; Koeppel, T A; Krings, T; Mess, W H; Schiefer, J; Jacobs, M J

    2010-06-01

    According to the results of the large trials on carotid endarterectomy (CEA), this type of surgery is only warranted if perioperative mortality and morbidity are kept considerably low. Less attention has been paid to methods of cerebral protection during CEA, although intraoperative transcranial Doppler (TCD) can visualise intracerebral microemboli (MES) during routine carotid dissection, although MES occur throughout the CEA, only those during dissection are related to neurological outcome. Prevention of MES by means of early control of the distal internal carotid artery dislodging from the carotid artery plaque during dissection is very likely the mechanism behind an eventual benefit from this approach. Hence, the amount of MES might serve as a surrogate parameter for the risk of periprocedural neurological events. So, the aim of the present study was to evaluate whether early control of the distal carotid artery during CEA is capable of reducing the number of MES by means of a prospective randomised trial. Twenty-eight patients (29 procedures) could be prospectively included in our study. Before surgery we randomly assigned the patients to two groups: group A (N.=12): CEA by means of early control of the distal internal carotid artery; group B (N.=17): CEA with dissection of the total carotid bifurcation before clamping the arteries. Periprocedurally, we continuously monitored the cerebral blood flow in the ipsilateral middle cerebral artery by means of TCD. Pre- and postoperative morbidity were independently verified by a neurologist control of the distal internal carotid artery did not reduce the occurrence of MES during dissection of the carotid bifurcation. Also, the total number of MES throughout the procedure and postoperatively was comparable between both groups. The procedure related times as well as the clinical outcome did not differ significantly. Thus, early control of the distal internal carotid artery has got no advantage but also no disadvantage

  10. Penetration of asbestos fibers in respirator filters

    International Nuclear Information System (INIS)

    Cheng, Yung-Sung; Pearson, S.D.; Rohrbacher, K.D.; Yeh, Hsu-Chi.

    1994-01-01

    Currently, the health risks associated with asbestos have restricted its use and created a growing asbestos abatement industry with a need for respirator filters that are effective for worker protection. The main purpose of this project is to determine the influence of fiber size, electrostatic charge, and flow rate on the penetration of asbestos fibers in respirator filter cartridges. The study includes four types of filters each tested at two flow rates: the AO-R57A, a dual cartridge HEPA filter tested at 16 and 42.5 L/min; the MSA-S, a dust and mist filter tested at 16 and 42.5 L/min; the MSA-A power filter tested at 32 and 85 L/min; and the 3M-8710, a low-efficiency disposable face mask filter tested at 32 and 85 L/min. The three types of asbestos fibers used (amosite, crocidolite, and chrysotile) ranged in length from 0.04-0.5 μm and in aspect ratio (ratio of length to diameter) from 3 to 60. The fibers were used in both charged and neutralized forms. The results from amosite fibers are reported here

  11. Dedusting and filtering technology; Entstaubungs- und Filtertechnik

    Energy Technology Data Exchange (ETDEWEB)

    Selck, S.; Stockmann, H.W.; Both, R. [Deutsche Montan Technologie GmbH, Essen (Germany). Gas and Fire Div.

    2004-07-01

    For the further development of the filtration and dedusting technology within the last research period the new regulations in occupational hygiene concerning dust as well as ISO and EN standards have been considered. Also the new requirements concerning fire and explosion protection filter materials based in the test regulations for synthetic materials have been taken into account. The adoption of these new regulations inhibits the further use of the available high effective filter materials in underground coal mines. The development of new filter materials has been forced by the test regulations for synthetic materials, as the specific aspects of electrostatic behaviour, soot and toxic gases formed by burning of filter materials impacting the CO self rescue filters, have been taken into account. Even these requirements are partially inhibiting high filter efficiencies and air flows, all the requirements have been fulfilled on a high level on filter efficiencies matching the present state of art in occupational hygiene as reported in the Silicosis Reports Vol. 20 and 21. (orig.)

  12. Hybrid Filter Membrane

    Science.gov (United States)

    Laicer, Castro; Rasimick, Brian; Green, Zachary

    2012-01-01

    Cabin environmental control is an important issue for a successful Moon mission. Due to the unique environment of the Moon, lunar dust control is one of the main problems that significantly diminishes the air quality inside spacecraft cabins. Therefore, this innovation was motivated by NASA s need to minimize the negative health impact that air-suspended lunar dust particles have on astronauts in spacecraft cabins. It is based on fabrication of a hybrid filter comprising nanofiber nonwoven layers coated on porous polymer membranes with uniform cylindrical pores. This design results in a high-efficiency gas particulate filter with low pressure drop and the ability to be easily regenerated to restore filtration performance. A hybrid filter was developed consisting of a porous membrane with uniform, micron-sized, cylindrical pore channels coated with a thin nanofiber layer. Compared to conventional filter media such as a high-efficiency particulate air (HEPA) filter, this filter is designed to provide high particle efficiency, low pressure drop, and the ability to be regenerated. These membranes have well-defined micron-sized pores and can be used independently as air filters with discreet particle size cut-off, or coated with nanofiber layers for filtration of ultrafine nanoscale particles. The filter consists of a thin design intended to facilitate filter regeneration by localized air pulsing. The two main features of this invention are the concept of combining a micro-engineered straight-pore membrane with nanofibers. The micro-engineered straight pore membrane can be prepared with extremely high precision. Because the resulting membrane pores are straight and not tortuous like those found in conventional filters, the pressure drop across the filter is significantly reduced. The nanofiber layer is applied as a very thin coating to enhance filtration efficiency for fine nanoscale particles. Additionally, the thin nanofiber coating is designed to promote capture of

  13. Backflushable filter insert

    International Nuclear Information System (INIS)

    Keith, R.C.; Vandenberg, T.; Randolph, M.C.; Lewis, T.B.; Gillis, P.J. Jr.

    1988-01-01

    Filter elements are mounted on a tube plate beneath an accumulator chamber whose wall is extended by skirt and flange to form a closure for the top of pressure vessel. The accumulator chamber is annular around a central pipe which serves as the outlet for filtered water passing from the filter elements. The chamber contains filtered compressed air from supply. Periodically the filtration of water is stopped and vessel is drained. Then a valve is opened, allowing the accumulated air to flow from chamber up a pipe and down pipe, pushing the filtered water from pipe back through the filter elements to clean them. The accumulator chamber is so proportioned, relative to the volume of the system communicating therewith during backflushing, that the equilibrium pressure during backflushing cannot exceed the pressure rating of the vessel. However a line monitors the pressure at the top of the vessel, and if it rises too far a bleed valve is automatically opened to depressurise the system. The chamber is intended to replace the lid of an existing vessel to convert a filter using filter aid to one using permanent filter elements. (author)

  14. Updating the OMERACT filter

    DEFF Research Database (Denmark)

    Wells, George; Beaton, Dorcas E; Tugwell, Peter

    2014-01-01

    The "Discrimination" part of the OMERACT Filter asks whether a measure discriminates between situations that are of interest. "Feasibility" in the OMERACT Filter encompasses the practical considerations of using an instrument, including its ease of use, time to complete, monetary costs......, and interpretability of the question(s) included in the instrument. Both the Discrimination and Reliability parts of the filter have been helpful but were agreed on primarily by consensus of OMERACT participants rather than through explicit evidence-based guidelines. In Filter 2.0 we wanted to improve this definition...

  15. Nanofiber Filters Eliminate Contaminants

    Science.gov (United States)

    2009-01-01

    With support from Phase I and II SBIR funding from Johnson Space Center, Argonide Corporation of Sanford, Florida tested and developed its proprietary nanofiber water filter media. Capable of removing more than 99.99 percent of dangerous particles like bacteria, viruses, and parasites, the media was incorporated into the company's commercial NanoCeram water filter, an inductee into the Space Foundation's Space Technology Hall of Fame. In addition to its drinking water filters, Argonide now produces large-scale nanofiber filters used as part of the reverse osmosis process for industrial water purification.

  16. Filters in nuclear facilities

    International Nuclear Information System (INIS)

    Berg, K.H.; Wilhelm, J.G.

    1985-01-01

    The topics of the nine papers given include the behavior of HEPA filters during exposure to air flows of high humidity as well as of high differential pressure, the development of steel-fiber filters suitable for extreme operating conditions, and the occurrence of various radioactive iodine species in the exhaust air from boiling water reactors. In an introductory presentation the German view of the performance requirements to be met by filters in nuclear facilities as well as the present status of filter quality assurance are discussed. (orig.) [de

  17. Washing method of filter

    International Nuclear Information System (INIS)

    Izumidani, Masakiyo; Tanno, Kazuo.

    1978-01-01

    Purpose: To enable automatic filter operation and facilitate back-washing operation by back-washing filters used in a bwr nuclear power plant utilizing an exhaust gas from a ventilator or air conditioner. Method: Exhaust gas from an exhaust pipe of an ventilator or air conditioner is pressurized in a compressor and then introduced in a back-washing gas tank. Then, the exhaust gas pressurized to a predetermined pressure is blown from the inside to the outside of a filter to thereby separate impurities collected on the filter elements and introduce them to a waste tank. (Furukawa, Y.)

  18. Young Children's Sibling Relationship Quality: Distal and Proximal Correlates

    Science.gov (United States)

    Kretschmer, Tina; Pike, Alison

    2009-01-01

    Background: Relationships within families are interdependent and related to distal environmental factors. Low socioeconomic status (SES) and high household chaos (distal factors) have been linked to less positive marital and parent-child relationships, but have not yet been examined with regard to young children's sibling relationships. The…

  19. Distal clavicular osteolysis: MR evidence for subchondral fracture

    Energy Technology Data Exchange (ETDEWEB)

    Kassarjian, Ara; Palmer, William E. [Massachusetts General Hospital, Department of Radiology, Division of Musculoskeletal Radiology, Yawkey Center, Boston, MA (United States); Llopis, Eva [Hospital de la Ribera, Department of Radiology, Valencia (Spain)

    2007-01-15

    To investigate the association between distal clavicular osteolysis and subchondral fractures of the distal clavicle at MRI. This study was approved by the hospital human research committee, which waived the need for informed consent. Three radiologists retrospectively analyzed 36 shoulder MR examinations in 36 patients with imaging findings of distal clavicular osteolysis. The presence of a subchondral fracture of the distal clavicle, abnormalities of the acromioclavicular joint, rotator cuff tears and labral tears were assessed by MRI. These cases were then compared with 36 age-matched controls. At MRI, 31 of 36 patients (86%) had a subchondral line within the distal clavicular edema, consistent with a subchondral fracture. Of the 36 patients, 32 (89%) had fluid in the acromioclavicular joint, while 27 of 36 patients (75%) had cysts or erosions in the distal clavicle. There were 13 patients (36%) with associated labral tears, while eight patients (22%) had partial-thickness rotator cuff tears. In the control group one of 36 (3%) had a subchondral line (P<0.05), while ten of 36 (28%) had rotator cuff tears and 13 of 36 (36%) had labral tears. These latter two were not statistically significant between the groups. A distal clavicular subchondral fracture is a common finding in patients with imaging evidence of distal clavicular osteolysis. These subchondral fractures may be responsible for the propensity of findings occurring on the clavicular side of the acromioclavicular joint. (orig.)

  20. Distal clavicular osteolysis: MR evidence for subchondral fracture

    International Nuclear Information System (INIS)

    Kassarjian, Ara; Palmer, William E.; Llopis, Eva

    2007-01-01

    To investigate the association between distal clavicular osteolysis and subchondral fractures of the distal clavicle at MRI. This study was approved by the hospital human research committee, which waived the need for informed consent. Three radiologists retrospectively analyzed 36 shoulder MR examinations in 36 patients with imaging findings of distal clavicular osteolysis. The presence of a subchondral fracture of the distal clavicle, abnormalities of the acromioclavicular joint, rotator cuff tears and labral tears were assessed by MRI. These cases were then compared with 36 age-matched controls. At MRI, 31 of 36 patients (86%) had a subchondral line within the distal clavicular edema, consistent with a subchondral fracture. Of the 36 patients, 32 (89%) had fluid in the acromioclavicular joint, while 27 of 36 patients (75%) had cysts or erosions in the distal clavicle. There were 13 patients (36%) with associated labral tears, while eight patients (22%) had partial-thickness rotator cuff tears. In the control group one of 36 (3%) had a subchondral line (P<0.05), while ten of 36 (28%) had rotator cuff tears and 13 of 36 (36%) had labral tears. These latter two were not statistically significant between the groups. A distal clavicular subchondral fracture is a common finding in patients with imaging evidence of distal clavicular osteolysis. These subchondral fractures may be responsible for the propensity of findings occurring on the clavicular side of the acromioclavicular joint. (orig.)

  1. Intra-articular osteotomy for distal humerus malunion

    NARCIS (Netherlands)

    Marti, René K.; Doornberg, Job

    2009-01-01

    Intra-articular osteotomy is considered in the rare case of malunion after a fracture of the distal humerus to restore humeral alignment and gain a functional arc of elbow motion. Traumatic and iatrogenic disruption of the limited blood flow to the distal end of the humerus resulting in avascular

  2. Clinical relevance of distal biceps insertional and footprint anatomy

    NARCIS (Netherlands)

    van den Bekerom, Michel P J; Kodde, Izaäk F.; Aster, Asir; Bleys, Ronald L A W; Eygendaal, Denise

    2016-01-01

    Purpose: The aim of this review was to present an overview, based on a literature search, of surgical anatomy for distal biceps tendon repairs, based on the current literature. Methods: A narrative review was performed using Pubmed/Medline using key words: Search terms were distal biceps,

  3. Distal tibiofibular synostosis in a Nigerian: A case report | Owoeye ...

    African Journals Online (AJOL)

    X-ray of the bones showed an oblique fracture in the distal end of the shaft of fibula which is suggestive of post traumatic tibiofibular synostosis (TFS). Knowledge of distal TFS is important in resolving the puzzle of chronic shin pain of unknown origin and in accurate diagnosis of causes of ankle deformity and malformations.

  4. Radiographic study of distal radial physeal closure in thoroughbred horses

    International Nuclear Information System (INIS)

    Vulcano, L.C.; Mamprim, M.J.; Muniz, L.M.R.; Moreira, A.F.; Luna, S.P.L.

    1997-01-01

    Monthly radiography was performed to study distal radial physeal closure in ten male and ten female Throughbred horses. The height, thoracic circumference and metacarpus circumference were also measured, Distal radial physeal closure time was sooner in females than males, and took 701 +/- 37 and 748 +/- 55 days respectively

  5. A FUNCTIONAL EVALUATION STUDY OF DISTAL FEMORAL FRACTURES FIXED WITH DISTAL FEMORAL LOCKING PLATE

    Directory of Open Access Journals (Sweden)

    Manikumar C. J

    2017-04-01

    Full Text Available BACKGROUND Fractures of the distal femur present considerable challenges in management. Older patients especially women sustain fractures due to osteoporosis. Supracondylar fractures of femur have a bimodal distribution. They account for 6% of all femur fractures and 31% if hip fractures were excluded. Nearly, 50% of distal femur intra-articular fractures are open fractures. Before 1970, most supracondylar fractures were treated nonoperatively; however, difficulties were often encountered including persistent angulatory deformity, knee joint incongruity, loss of knee motion and delayed mobilisation. The trend of open reduction and internal fixation has become evident in recent years with good results being obtained with AO blade plate, dynamic condylar screw, intramedullary supracondylar nail and locking compression plate. Elderly patients and osteoporosis pose difficulty in treating intra-articular fractures of the lower end of femur. Loss of stable fixation is of great concern in these cases. Hence, locking compression plate use has an advantage in these patients. MATERIALS AND METHODS In this study, 20 patients with closed fracture of distal femur were studied. All the cases were treated at the Department of Orthopaedics, Rangaraya Medical College/Government General Hospital, Kakinada, Andhra Pradesh, between November 2013 and November 2015. The method used for fracture fixation was open reduction and internal fixation with distal femoral locking plate. The duration of follow up ranged from 3 months to 24 months. All the fractures in this series were posttraumatic. The patients were functionally evaluated with Neer’s scoring system. 1 RESULTS Twenty distal femoral fractures were treated with distal femoral locking plates. 15 patients were males and 5 patients were females. The median age was 47 years ranging from 28-70 years. 16 of the fractures were caused by road traffic accidents and 2 were due to fall, 2 were due to assault. 12 patients

  6. Storm Water Pollution Removal Performance of Compost Filter Socks

    Science.gov (United States)

    In 2005, the US Environmental Protection Agency National Menu of Best Management Practices (BMPs) listed compost filter socks as an approved BMP for controlling sediment in storm runoff on construction sites. Filtrexx International manufactures and distributes Filter Soxx (FS). Literature suggests...

  7. Air filters for use at nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Linder, P [Aktiebolaget Atomenergi, Studsvik, Nykoeping (Sweden)

    1970-12-01

    The ventilation system of a nuclear facility plays a vital role in ensuring that the air in working areas and the environment remains free from radioactive contamination. An earlier IAEA publication, Techniques for Controlling Air Pollution from the Operation of Nuclear Facilities, Safety Series No. 17, deals with the design and operation of ventilation systems at nuclear facilities. These systems are usually provided with air-cleaning devices which remove the contaminants from the air. This publication is intended as a guide to those who are concerned with the design of air-filtering systems and with the testing, operation and maintenance of air-filter installations at nuclear facilities. Emphasis is mainly placed on so-called high-efficiency particulate air filters (HEPA filters) and on providing general information on them. Besides describing the usual filter types, their dimensions and construction materials, the guidebook attempts to explain their properties and behaviour under different operating conditions. It also gives advice on testing and handling the filters so that effective and safe performance is ensured. The guidebook should serve as an introduction to the use of high efficiency particulate air filters in countries where work with radioactive materials has only recently commenced. The list of references at the end of the book indicates sources of more advanced information for those who already have comprehensive experience in this field. It is assumed here that the filters are obtained from a manufacturer, and the guidebook thus contains no information on the design and development of the filter itself, nor does it deal with the cleaning of the intake air to a plant, with gas sorption or protective respiratory equipment.

  8. Air filters for use at nuclear facilities

    International Nuclear Information System (INIS)

    Linder, P.

    1970-01-01

    The ventilation system of a nuclear facility plays a vital role in ensuring that the air in working areas and the environment remains free from radioactive contamination. An earlier IAEA publication, Techniques for Controlling Air Pollution from the Operation of Nuclear Facilities, Safety Series No. 17, deals with the design and operation of ventilation systems at nuclear facilities. These systems are usually provided with air-cleaning devices which remove the contaminants from the air. This publication is intended as a guide to those who are concerned with the design of air-filtering systems and with the testing, operation and maintenance of air-filter installations at nuclear facilities. Emphasis is mainly placed on so-called high-efficiency particulate air filters (HEPA filters) and on providing general information on them. Besides describing the usual filter types, their dimensions and construction materials, the guidebook attempts to explain their properties and behaviour under different operating conditions. It also gives advice on testing and handling the filters so that effective and safe performance is ensured. The guidebook should serve as an introduction to the use of high efficiency particulate air filters in countries where work with radioactive materials has only recently commenced. The list of references at the end of the book indicates sources of more advanced information for those who already have comprehensive experience in this field. It is assumed here that the filters are obtained from a manufacturer, and the guidebook thus contains no information on the design and development of the filter itself, nor does it deal with the cleaning of the intake air to a plant, with gas sorption or protective respiratory equipment

  9. Comparison of testing methods for particulate filters

    International Nuclear Information System (INIS)

    Ullmann, W.; Przyborowski, S.

    1983-01-01

    Four testing methods for particulate filters were compared by using the test rigs of the National Board of Nuclear Safety and Radiation Protection: 1) Measurement of filter penetration P as a function of particle size d by using a polydisperse NaC1 test aerosol and a scintillation particle counter; 2) Modified sodium flame test for measurement of total filter penetration P for various polydisperse NaC1 test aerosols; 3) Measurement of total filter penetration P for a polydisperse NaC1 test aerosol labelled with short-lived radon daughter products; 4) Measurement of total filter penetration P for a special paraffin oil test aerosol (oil fog test used in FRG according DIN 24 184, test aerosol A). The investigations were carried out on sheets of glass fibre paper (five grades of paper). Detailed information about the four testing methods and the used particle size distributions is given. The different results of the various methods are the base for the discussion of the most important parameters which influence the filter penetration P. The course of the function P=f(d) shows the great influence of the particle size. As expected there was also found a great dependence both from the test aerosol as well as from the principle and the measuring range of the aerosol-measuring device. The differences between the results of the various test methods are greater the lower the penetration. The use of NaCl test aerosol with various particle size distributions gives great differences for the respective penetration values. On the basis of these results and the values given by Dorman conclusions are made about the investigation of particulate filters both for the determination of filter penetration P as well as for the leak test of installed filters

  10. Multilevel ensemble Kalman filter

    KAUST Repository

    Chernov, Alexey; Hoel, Haakon; Law, Kody; Nobile, Fabio; Tempone, Raul

    2016-01-01

    This work embeds a multilevel Monte Carlo (MLMC) sampling strategy into the Monte Carlo step of the ensemble Kalman filter (EnKF). In terms of computational cost vs. approximation error the asymptotic performance of the multilevel ensemble Kalman filter (MLEnKF) is superior to the EnKF s.

  11. Neutron Beam Filters

    International Nuclear Information System (INIS)

    Adib, M.

    2011-01-01

    The purpose of filters is to transmit neutrons with selected energy, while remove unwanted ones from the incident neutron beam. This reduces the background, and the number of spurious. The types of commonly used now-a-day neutron filters and their properties are discussed in the present work. There are three major types of neutron filters. The first type is filter of selective thermal neutron. It transmits the main reflected neutrons from a crystal monochromate, while reject the higher order contaminations accompanying the main one. Beams coming from the moderator always contain unwanted radiation like fast neutrons and gamma-rays which contribute to experimental background and to the biological hazard potential. Such filter type is called filter of whole thermal neutron spectrum. The third filter type is it transmits neutrons with energies in the resonance energy range (En . 1 KeV). The main idea of such neutron filter technique is the use of large quantities of a certain material which have the deep interference minima in its total neutron cross-section. By transmitting reactor neutrons through bulk layer of such material, one can obtain the quasimonochromatic neutron lines instead of white reactor spectrum.

  12. Side loading filter apparatus

    International Nuclear Information System (INIS)

    Reynolds, K.E.

    1981-01-01

    A side loading filter chamber for use with radioactive gases is described. The equipment incorporates an inexpensive, manually operated, mechanism for aligning filter units with a number of laterally spaced wall openings and for removing the units from the chamber. (U.K.)

  13. Multilevel ensemble Kalman filter

    KAUST Repository

    Chernov, Alexey

    2016-01-06

    This work embeds a multilevel Monte Carlo (MLMC) sampling strategy into the Monte Carlo step of the ensemble Kalman filter (EnKF). In terms of computational cost vs. approximation error the asymptotic performance of the multilevel ensemble Kalman filter (MLEnKF) is superior to the EnKF s.

  14. Rehabilitation for distal radial fractures in adults.

    Science.gov (United States)

    Handoll, Helen H G; Elliott, Joanne

    2015-09-25

    Fracture of the distal radius is a common clinical problem, particularly in older people with osteoporosis. There is considerable variation in the management, including rehabilitation, of these fractures. This is an update of a Cochrane review first published in 2002 and last updated in 2006. To examine the effects of rehabilitation interventions in adults with conservatively or surgically treated distal radial fractures. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL 2014; Issue 12), MEDLINE, EMBASE, CINAHL, AMED, PEDro, OTseeker and other databases, trial registers, conference proceedings and reference lists of articles. We did not apply any language restrictions. The date of the last search was 12 January 2015. Randomised controlled trials (RCTs) or quasi-RCTs evaluating rehabilitation as part of the management of fractures of the distal radius sustained by adults. Rehabilitation interventions such as active and passive mobilisation exercises, and training for activities of daily living, could be used on their own or in combination, and be applied in various ways by various clinicians. The review authors independently screened and selected trials, and reviewed eligible trials. We contacted study authors for additional information. We did not pool data. We included 26 trials, involving 1269 mainly female and older patients. With few exceptions, these studies did not include people with serious fracture or treatment-related complications, or older people with comorbidities and poor overall function that would have precluded trial participation or required more intensive treatment. Only four of the 23 comparisons covered by these 26 trials were evaluated by more than one trial. Participants of 15 trials were initially treated conservatively, involving plaster cast immobilisation. Initial treatment was surgery (external fixation or internal fixation) for all participants

  15. Distal Stressors and Depression among Homeless Men.

    Science.gov (United States)

    Coohey, Carol; Easton, Scott D

    2016-05-01

    Depression is a common problem among homeless men that may interfere with functional tasks, such as securing stable housing, obtaining employment, and accessing health services. Previous research on depression among homeless men has largely focused on current psychosocial resources, substance abuse, and past victimization. Guided by Ensel and Lin's life course stress process model, the authors examined whether distal stressors, including victimization and exposure to parent problems in childhood, contributed to men's depression above and beyond current (or proximal) stressors, such as substance abuse and health problems, and social resources. The sample consisted of 309 homeless men who had entered a federally funded emergency shelter. Using the Burns Depression Checklist, the authors found that one out of three men met the threshold for moderate to severe depression during the past week. The logistic regression showed that past exposure to parent problems was related to depression after accounting for current stressors and social resources (number of close adult relationships and whether their emotional support needs were met). Past victimization was not related to depression. To address men's depression, workers should concurrently provide services that meet men's basic needs (for example, housing) and address their relationship needs, including their need for emotional support.

  16. Filtering and prediction

    CERN Document Server

    Fristedt, B; Krylov, N

    2007-01-01

    Filtering and prediction is about observing moving objects when the observations are corrupted by random errors. The main focus is then on filtering out the errors and extracting from the observations the most precise information about the object, which itself may or may not be moving in a somewhat random fashion. Next comes the prediction step where, using information about the past behavior of the object, one tries to predict its future path. The first three chapters of the book deal with discrete probability spaces, random variables, conditioning, Markov chains, and filtering of discrete Markov chains. The next three chapters deal with the more sophisticated notions of conditioning in nondiscrete situations, filtering of continuous-space Markov chains, and of Wiener process. Filtering and prediction of stationary sequences is discussed in the last two chapters. The authors believe that they have succeeded in presenting necessary ideas in an elementary manner without sacrificing the rigor too much. Such rig...

  17. Sub-micron filter

    Science.gov (United States)

    Tepper, Frederick [Sanford, FL; Kaledin, Leonid [Port Orange, FL

    2009-10-13

    Aluminum hydroxide fibers approximately 2 nanometers in diameter and with surface areas ranging from 200 to 650 m.sup.2/g have been found to be highly electropositive. When dispersed in water they are able to attach to and retain electronegative particles. When combined into a composite filter with other fibers or particles they can filter bacteria and nano size particulates such as viruses and colloidal particles at high flux through the filter. Such filters can be used for purification and sterilization of water, biological, medical and pharmaceutical fluids, and as a collector/concentrator for detection and assay of microbes and viruses. The alumina fibers are also capable of filtering sub-micron inorganic and metallic particles to produce ultra pure water. The fibers are suitable as a substrate for growth of cells. Macromolecules such as proteins may be separated from each other based on their electronegative charges.

  18. Monolithic Integrated Ceramic Waveguide Filters

    OpenAIRE

    Hunter, IC; Sandhu, MY

    2014-01-01

    Design techniques for a new class of integrated monolithic high permittivity ceramic waveguide filters are presented. These filters enable a size reduction of 50% compared to air-filled TEM filters with the same unloaded Q-Factor. Designs for both chebyshev and asymmetric generalized chebyshev filter are presented, with experimental results for an 1800 MHz chebyshev filter showing excellent agreement with theory.

  19. One-stage lengthening using a locked nailing technique for distal femoral shaft nonunions associated with shortening.

    Science.gov (United States)

    Wu, Chi-Chuan; Lee, Zhon-Liau

    2004-02-01

    To assess the effectiveness of a one-stage lengthening using a locked nail technique for the treatment of distal femoral shaft nonunions associated with shortening. Retrospective. University hospital. During a 6-year period, 36 distal femoral shaft nonunions associated with shortening (>1.5 cm) were treated by the one-stage lengthening technique. Indications for this technique were distal femoral shaft aseptic or quiescent infected nonunions, 1.5-5 cm shortening, and a fracture level suitable for the insertion of two distal locked screws. The surgical technique involved skeletal traction using the femoral condyle, local débridement, lengthening by lengthening was 2.5 cm (range 1.5-3.5 cm). One-stage lengthening using the locked nailing technique to treat distal femoral shaft nonunions associated with shortening can achieve a high success rate and low complication rate. The key to successful treatment is the patient's complete cooperation with strictly protected weight bearing until the fracture has healed.

  20. [Light protection: principles of UV protection].

    Science.gov (United States)

    Stege, H; Mang, R

    2006-05-01

    UV radiation is responsible for the induction of epithelial and melanocytic skin cancer, photoaging, and photodermatoses. UV protection is necessary to prevent damage caused by non-physiologic exposure. UV protection includes not only reduction of sun exposure but also use of sun protective filters, UV protective clothes, DNA repair enzymes, and antioxidant supplementation. Consumers are uncertain about the possibilities and limitations of commercial sun protection measures. Dermatologists must explain protective measures to the general public which continues to believe that UV-tanned skin is healthy. The sunscreen market is a highly competitive but lucrative market. The range of products with different designations and promises makes difficult for both consumers and dermatologists to determine what is sensible UV protection.

  1. Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting. Comparison of several anti-embolic protection devices

    International Nuclear Information System (INIS)

    Taha, M.M.; Maeda, Masayuki; Sakaida, Hiroshi

    2009-01-01

    Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm 3 vs. 86.9 mm 3 , respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm 3 ) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm 3 and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions. (author)

  2. Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting: Comparison of several anti-embolic protection devices.

    Science.gov (United States)

    Taha, Mahmoud M; Maeda, Masayuki; Sakaida, Hiroshi; Kawaguchi, Kenji; Toma, Naoki; Yamamoto, Akitaka; Hirose, Tomofumi; Miura, Youichi; Fujimoto, Masashi; Matsushima, Satoshi; Taki, Waro

    2009-09-01

    Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm(3) vs. 86.9 mm(3), respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm(3)) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm(3) and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions.

  3. A comparison between robotic-assisted laparoscopic distal pancreatectomy versus laparoscopic distal pancreatectomy.

    Science.gov (United States)

    Goh, Brian K P; Chan, Chung Yip; Soh, Hui-Ling; Lee, Ser Yee; Cheow, Peng-Chung; Chow, Pierce K H; Ooi, London L P J; Chung, Alexander Y F

    2017-03-01

    This study aims to compare the early perioperative outcomes of robotic-assisted laparoscopic distal pancreatectomy (RDP) versus laparoscopic distal pancreatectomy (LDP). The clinicopathologic features of 45 consecutive patients who underwent minimally-invasive distal pancreatectomy from 2006 to 2015 were retrospectively reviewed. Thirty-nine patients who met our study criteria were included. Eight patients underwent RDP and 31 had LDP. There were 10 (25.6%) open conversions. Six (15.4%) patients had major (> grade 2) morbidities and there was no in-hospital mortality. There were 14 (35.9%) grade A and 9 (23.1%) grade B pancreatic fistulas. Comparison between RDP and LDP demonstrated no significant difference between the patients' baseline characteristics except there was increased frequency of spleen-preserving pancreatectomies (3 (37.5%) vs 25 (80.6%), P=0.016) and splenic-vessel preservation (5 (62.5%) vs 4 (12.9%), P=0.003) in RDP. Comparison between outcomes demonstrated that RDP was associated with a longer median operation time (452.5 (range, 300-685) vs 245 min (range, 85-430), P=0.001) and increased frequency of the procedure completed purely laparoscopically (8 (100%) vs 18 (58.1%), P=0.025). RDP can be safely adopted and is equivalent to LDP in most perioperative outcomes. It is also associated with a decreased frequency of the need for hand-assistance laparoscopic surgery or open conversion but needed a longer operation time. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Unilateral maxillary molar distalization with zygoma-gear appliance.

    Science.gov (United States)

    Kilkis, Dogan; Bayram, Mehmet; Celikoglu, Mevlut; Nur, Metin

    2012-08-01

    The aim of this study was to present the orthodontic treatment of a 15-year-old boy with a unilateral maxillary molar distalization system, called the zygoma-gear appliance. It consisted of a zygomatic anchorage miniplate, an inner bow, and a Sentalloy closed coil spring (GAC International, Bohemia, NY). A distalizing force of 350 g was used during the distalization period. The unilateral Class II malocclusion was corrected in 5 months with the zygoma-gear appliance. The maxillary left first molar showed distalization of 4 mm with an inclination of 3°. The maxillary premolars moved distally with the help of the transseptal fibers. In addition, there were slight decreases in overjet (-0.5 mm) and maxillary incisor inclination (-1°), indicating no anchorage loss from the zygoma-gear appliance. Preadjusted fixed appliances (0.022 × 0.028-in, MBT system; 3M Unitek, Monrovia, Calif) were placed in both arches to achieve leveling and alignment. After 14 months of unilateral distalization with the zygoma-gear appliance and fixed appliances, Class I molar and canine relationships were established with satisfactory interdigitation of the posterior teeth. Acceptable overjet and overbite were also achieved. This article shows that this new system, the zygoma-gear appliance, can be used for unilateral maxillary molar distalization without anchorage loss. Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  5. Penetration of Combustion Aerosol Particles Through Filters of NIOSH-Certified Filtering Facepiece Respirators (FFRs).

    Science.gov (United States)

    Gao, Shuang; Kim, Jinyong; Yermakov, Michael; Elmashae, Yousef; He, Xinjian; Reponen, Tiina; Grinshpun, Sergey A

    2015-01-01

    Filtering facepiece respirators (FFRs) are commonly worn by first responders, first receivers, and other exposed groups to protect against exposure to airborne particles, including those originated by combustion. Most of these FFRs are NIOSH-certified (e.g., N95-type) based on the performance testing of their filters against charge-equilibrated aerosol challenges, e.g., NaCl. However, it has not been examined if the filtration data obtained with the NaCl-challenged FFR filters adequately represent the protection against real aerosol hazards such as combustion particles. A filter sample of N95 FFR mounted on a specially designed holder was challenged with NaCl particles and three combustion aerosols generated in a test chamber by burning wood, paper, and plastic. The concentrations upstream (Cup) and downstream (Cdown) of the filter were measured with a TSI P-Trak condensation particle counter and a Grimm Nanocheck particle spectrometer. Penetration was determined as (Cdown/Cup) ×100%. Four test conditions were chosen to represent inhalation flows of 15, 30, 55, and 85 L/min. Results showed that the penetration values of combustion particles were significantly higher than those of the "model" NaCl particles (p combustion particles. Aerosol type, inhalation flow rate and particle size were significant (p combustion particles through R95 and P95 FFR filters (were tested in addition to N95) were not significantly higher than that obtained with NaCl particles. The findings were attributed to several effects, including the degradation of an N95 filter due to hydrophobic organic components generated into the air by combustion. Their interaction with fibers is anticipated to be similar to those involving "oily" particles. The findings of this study suggest that the efficiency of N95 respirator filters obtained with the NaCl aerosol challenge may not accurately predict (and rather overestimate) the filter efficiency against combustion particles.

  6. Field evaluation of prototype electrofibrous filters

    International Nuclear Information System (INIS)

    Kuhl, W.D.; Bergman, W.; Biermann, A.H.; Lum, B.Y.

    1982-01-01

    New prototype electrofibrous filters were designed, built and evaluated in laboratory tests and in field installations. Two prototypes were designed for use in nuclear ventilation ducts as prefilters to HEPA filters. One prototype is designed to be a permanent component of the ventilation system while the other is a disposable unit. The disposable electrofibrous prefilter was installed in the exhaust stream of a glove box in which barrels of uranium turnings are burned. Preliminary tests show the disposal prefilter is effectively prolonging the HEPA filter life. An earlier prototype of the rolling prefilter was upgraded to meet the increased requirements for installation in a nuclear facility. This upgraded prototype was evaluated in the fire test facility at LLNL and shown to be effective in protecting HEPA filters from plugging under the most severe smoke conditions. The last prototype described in this report is a recirculating air filter. After demonstrating a high performance in laboratory tests the unit was shipped to Savannah River where it is awaiting installation in a Pu fuel fabrication facility. An analysis of the particulate problem in Savannah River indicates that four recirculating air filter will save $172,000 per year in maintenance costs

  7. Potassium transport across guinea pig distal colon

    International Nuclear Information System (INIS)

    Rechkemmer, G.; Halm, D.R.; Frizzell, R.A.

    1986-01-01

    Active absorption and secretion of K was studied by measuring bidirectional 42 K fluxes across short-circuited guinea pig distal colon. Tissues were pretreated with mucosal (m) and serosal (s) indomethacin (1 μM) and amiloride (0.1 mM, m) to suppress spontaneous, electrogenic Cl secretion and Na absorption. Under these conditions, the short-circuit current (I/sub sc/) was 0.4 μeq/cm 2 h while electroneutral K absorption was 2.8 μeq/cm 2 h. Epinephrine (5 μM, s) stimulated electrogenic K secretion, reducing net K absorption to 1.3 μeq/cm 2 h. Bumetanide (0.1 mM, s) abolished this K secretion and restored K absorption to control values, suggesting mechanistic similarities between K and Cl secretion. K absorption was inhibited 40% by the gastric H/K ATPase inhibitor, omeprazole (0.1 mM, m), and was abolished by ouabain (0.1 mM, m). Neutral K absorption does not appear to be mediated by an apical membrane Na/K pump since: the effect of mucosal ouabain on K absorption does not require the presence of mucosal or serosal Na, unidirectional Na fluxes are not influenced by mucosal ouabain, and K absorption is not affected when Na absorption is abolished by amiloride. Net K transport is determined by the balance between electroneutral K absorption and electrogenic K secretion. The ouabain sensitivity of K absorption suggests that colonic H/K ATPase differs from its gastric counterpart

  8. Histology of the distal dural ring.

    Science.gov (United States)

    Graffeo, Christopher S; Perry, Avital; Copeland, William R; Raghunathan, Aditya; Link, Michael J

    2017-09-01

    The distal dural ring (DDR) is a conserved intracranial anatomic structure marking the boundary point at which the internal carotid artery (ICA) exits the cavernous sinus (CS) and enters the subarachnoid space. Although the CS has been well described in a range of anatomic studies, to our knowledge no prior study has analyzed the histologic relationship between the ICA and DDR. Correspondingly, our objective was to assess the relationship of the DDR to the ICA and determine whether the DDR can be dissected from the ICA and thus divided, or can only be circumferentially trimmed around the artery. The authors examined ten fresh-frozen, adult cadaveric specimens. A standard frontotemporal craniotomy, orbito-optic osteotomy, and extradural anterior clinoidectomy was performed bilaterally. The cavernous ICA, DDR, and supraclinoid ICA were harvested as an en bloc specimen. Specimens formalin-fixed and paraffin-embedded prior to routine histochemical staining with hematoxylin and eosin and Masson trichrome. In all specimens, marked microscopic investment of the DDR throughout the ICA adventitia was noted. Dural collagen fibers extensively permeated the arterial layers superficial to the muscularis propria, with no evidence of a clear separation between the DDR and arterial adventitia. Histologic analysis suggests that the ICA and DDR are highly interrelated, continuous structures, and therefore attempted intraoperative dissection between these structures may carry an elevated risk of injury to the ICA. We correspondingly recommend careful circumferential trimming of the DDR in lieu of direct dissection in cases requiring mobilization of the clinoidal ICA. Clin. Anat. 30:742-746, 2017. © 2017Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  9. Two-wave propagation in in vitro swine distal ulna

    Science.gov (United States)

    Mano, Isao; Horii, Kaoru; Matsukawa, Mami; Otani, Takahiko

    2015-07-01

    Ultrasonic transmitted waves were obtained in an in vitro swine distal ulna specimen, which mimics a human distal radius, that consists of interconnected cortical bone and cancellous bone. The transmitted waveforms appeared similar to the fast waves, slow waves, and overlapping fast and slow waves measured in the specimen after removing the surface cortical bone (only cancellous bone). In addition, the circumferential waves in the cortical bone and water did not affect the fast and slow waves. This suggests that the fast-and-slow-wave phenomenon can be observed in an in vivo human distal radius.

  10. Intra-Articular Osteotomy for Distal Humerus Malunion

    Directory of Open Access Journals (Sweden)

    René K. Marti

    2009-01-01

    Full Text Available Intra-articular osteotomy is considered in the rare case of malunion after a fracture of the distal humerus to restore humeral alignment and gain a functional arc of elbow motion. Traumatic and iatrogenic disruption of the limited blood flow to the distal end of the humerus resulting in avascular necrosis of capitellum or trochlea is a major pitfall of the this technically challenging procedure. Two cases are presented which illustrate the potential problems of intra-articular osteotomy for malunion of the distal humerus.

  11. Carotid artery stenting in high surgical risk patients using the FiberNet embolic protection system: the EPIC trial results.

    Science.gov (United States)

    Myla, Subbarao; Bacharach, J Michael; Ansel, Gary M; Dippel, Eric J; McCormick, Daniel J; Popma, Jeffrey J

    2010-05-01

    The multicenter EPIC (FiberNet Embolic Protection System in Carotid Artery Stenting Trial) single-arm trial evaluated the 30-day outcomes of a new design concept for embolic protection during carotid artery stenting (CAS). Embolic protection filters available for use during CAS include fixed and over-the-wire systems that rely on embolic material capture within a "basket" structure. The FiberNet Embolic Protection System (EPS), which features a very low crossing profile, consists of a three-dimensional fiber-based filter distally mounted on a 0.014 inch guidewire with integrated aspiration during filter retrieval. The trial enrolled 237 patients from 26 centers. Demographics, clinical and lesion characteristics, as well as adverse events through a 30-day follow-up were recorded. The mean age of the patients was 74 years, 64% were male and 20% had symptomatic carotid artery disease. The combined major adverse event (MAE) rate at 30 days for all death, stroke, and myocardial infarction was 3.0%. There were three major strokes (two ischemic and one hemorrhagic) and two minor strokes (both ischemic) for a 2.1% 30-day stroke rate. The procedural technical success rate was 97.5% and macroscopic evidence of debris was reported in 90.9% of the procedures. The FiberNet EPS, used with commercially available stents, produced low stroke rates following CAS in high surgical risk patients presenting with carotid artery disease. The unique filter design including aspiration during retrieval may have contributed to the low 30-day stroke rate reported during CAS in patients considered at high risk for complications following carotid endarterectomy (CEA). Copyright 2010 Wiley-Liss, Inc.

  12. Circuits and filters handbook

    CERN Document Server

    Chen, Wai-Kai

    2003-01-01

    A bestseller in its first edition, The Circuits and Filters Handbook has been thoroughly updated to provide the most current, most comprehensive information available in both the classical and emerging fields of circuits and filters, both analog and digital. This edition contains 29 new chapters, with significant additions in the areas of computer-aided design, circuit simulation, VLSI circuits, design automation, and active and digital filters. It will undoubtedly take its place as the engineer's first choice in looking for solutions to problems encountered in the design, analysis, and behavi

  13. EMI filter design

    CERN Document Server

    Ozenbaugh, Richard Lee

    2011-01-01

    With today's electrical and electronics systems requiring increased levels of performance and reliability, the design of robust EMI filters plays a critical role in EMC compliance. Using a mix of practical methods and theoretical analysis, EMI Filter Design, Third Edition presents both a hands-on and academic approach to the design of EMI filters and the selection of components values. The design approaches covered include matrix methods using table data and the use of Fourier analysis, Laplace transforms, and transfer function realization of LC structures. This edition has been fully revised

  14. Randomized Filtering Algorithms

    DEFF Research Database (Denmark)

    Katriel, Irit; Van Hentenryck, Pascal

    2008-01-01

    of AllDifferent and is generalization, the Global Cardinality Constraint. The first delayed filtering scheme is a Monte Carlo algorithm: its running time is superior, in the worst case, to that of enforcing are consistency after every domain event, while its filtering effectiveness is analyzed...... in the expected sense. The second scheme is a Las Vegas algorithm using filtering triggers: Its effectiveness is the same as enforcing are consistency after every domain event, while in the expected case it is faster by a factor of m/n, where n and m are, respectively, the number of nodes and edges...

  15. Impact of a silver layer on the membrane of tap water filters on the microbiological quality of filtered water

    Directory of Open Access Journals (Sweden)

    Bruderek Juliane

    2008-10-01

    Full Text Available Abstract Background Bacteria in the hospital's drinking water system represent a risk for the acquisition of a nosocomial infection in the severely immunocompromised host. Terminal tap water filters may be used to prevent nosocomial Legionnaires' disease. We present data from water samples using an improved kind of tap water filters. Methods In a blinded study on an intermediate care unit of the thoracic surgery department, a modified type of the Germlyser water filter (Aqua-Free Membrane Technology with a newly-introduced silver layer on the filtration membrane was compared to its preceding type without such a layer on 15 water outlets. We determined growth of Legionella, other pathogenic bacteria, and the total heterotrophic plate count in unfiltered water and filtered water samples after filter usage intervals of 1 through 4 weeks. Results A total of 299 water samples were tested. Twenty-nine of the 60 unfiltered water samples contained Legionella of various serogroups (baseline value. In contrast, all samples filtered by the original water filter and all but one of the water samples filtered by the modified filter type remained Legionella-free. No other pathogenic bacteria were detected in any filtered sample. The total plate count in water samples increased during use of both kinds of filters over time. However, for the first 7 days of use, there were significantly fewer water samples containing >100 CFU per mL when using the new filter device compared with the older filters or taps with no filter. No advantage was seen thereafter. Conclusion The use of this type of terminal water filter is an appropriate method to protect immunocompromised patients from water-borne pathogens such as Legionella.

  16. In-situ testing of HEPA filters in the nuclear Karlsruhe filter system

    International Nuclear Information System (INIS)

    Ohlmeyer, M.; Stotz, W.

    1977-01-01

    Nuclear plant operators and filter manufacturers are endeavouring to improve environmental protection by intensifying process control and/or improving filter quality. In-situ testing is an important element in these efforts since it represents a direct means of checking the success or otherwise of a particular development. The arrangements for in-situ testing should satisfy the following minimum requirements: the staff should not be exposed to risk during the test; the test method should be objective and reproducible as well as being as sensitive as possible; the test method should permit detection of individual leaks in the filter system so that they can be remedied as efficiently as possible; the test equipment should not necessitate modifications to the extract systems or plant construction; the test should be simple and capable of being carried out with a minimum of effort and equipment. GfK has developed the 'Nuclear-Karlsruhe' filter housing in accordance with these principles. This housing permits in-situ testing similar to the DIN 24184 visual oil-fog test or the DOP test. External visual checks on the general condition of the filter is also possible. A safe system of filter changing with a specially designed plastic bag attachment at an accessible height considerably increases the degree of protection of operating personnel

  17. The distally-based island ulnar artery perforator flap for wrist defects

    Directory of Open Access Journals (Sweden)

    Karki Durga

    2007-01-01

    Full Text Available Background: Reconstruction of soft tissue defects around the wrist with exposed tendons, joints, nerves and bone represents a challenge to plastic surgeons, and such defects necessitate flap coverage to preserve hand functions and to protect its vital structures. We evaluated the use of a distally-based island ulnar artery perforator flap in patients with volar soft tissue defects around the wrist. Materials and Methods: Between June 2004 and June 2006, seven patients of soft tissue defects on the volar aspect of the wrist underwent distally-based island ulnar artery perforator flap. Out of seven patients, five were male and two patients were female. This flap was used in the reconstruction of the post road traffic accident defects in four patients and post electric burn defects in three patients. Flap was raised on one or two perforators and was rotated to 180°. Results: All flaps survived completely. Donor sites were closed primarily without donor site morbidity. Conclusion: The distally-based island Ulnar artery perforator flap is convenient, reliable, easy to manage and is a single-stage technique for reconstructing soft tissue defects of the volar aspect of the wrist. Early use of this flap allows preservation of vital structures, decreases morbidity and allows for early rehabilitation.

  18. Experiment on a multilayer type air filter for the filtration of sodium aerosol

    International Nuclear Information System (INIS)

    Otake, N.; Nozaki, O.

    1987-01-01

    An emergency air filter system of FBR was developed by using a multilayer type filter to protect the function of HEPA filter from clogging due to loading of sodium aerosol. To examine the effect of loading of sodium aerosol on the filter system, sodium aerosol consisting of sodium oxides and the related compound was supplied to the filter system. Several parameters to determine the effectiveness of the multilayer type filter were surveyed. It was confirmed that the emergency air filter system of FBR consisting of the multilayer type filter, a medium filter, HEPA filter with standard size (610 mm x 610 mm) in series could hold 800 g-Na at 1.5 kPa without clogging

  19. Combined open proximal and stent-graft distal repair for distal arch aneurysms: an alternative to total debranching.

    Science.gov (United States)

    Zierer, Andreas; Sanchez, Luis A; Moon, Marc R

    2009-07-01

    We present herein a novel, combined, simultaneous open proximal and stent-graft distal repair for complex distal aortic arch aneurysms involving the descending aorta. In the first surgical step, the transverse arch is opened during selective antegrade cerebral perfusion, and a Dacron graft (DuPont, Wilmington, DE) is positioned down the descending aorta in an elephant trunk-like fashion with its proximal free margin sutured circumferentially to the aorta just distal to the left subclavian or left common carotid artery. With the graft serving as the new proximal landing zone, subsequent endovascular repair is performed antegrade during rewarming through the ascending aorta.

  20. Metalcasting: Filtering Molten Metal

    International Nuclear Information System (INIS)

    Lauren Poole; Lee Recca

    1999-01-01

    A more efficient method has been created to filter cast molten metal for impurities. Read about the resulting energy and money savings that can accrue to many different industries from the use of this exciting new technology

  1. Perspectives on Nonlinear Filtering

    KAUST Repository

    Law, Kody

    2015-01-01

    The solution to the problem of nonlinear filtering may be given either as an estimate of the signal (and ideally some measure of concentration), or as a full posterior distribution. Similarly, one may evaluate the fidelity of the filter either by its ability to track the signal or its proximity to the posterior filtering distribution. Hence, the field enjoys a lively symbiosis between probability and control theory, and there are plenty of applications which benefit from algorithmic advances, from signal processing, to econometrics, to large-scale ocean, atmosphere, and climate modeling. This talk will survey some recent theoretical results involving accurate signal tracking with noise-free (degenerate) dynamics in high-dimensions (infinite, in principle, but say d between 103 and 108 , depending on the size of your application and your computer), and high-fidelity approximations of the filtering distribution in low dimensions (say d between 1 and several 10s).

  2. HEPA air filter (image)

    Science.gov (United States)

    ... pet dander and other irritating allergens from the air. Along with other methods to reduce allergens, such ... controlling the amount of allergens circulating in the air. HEPA filters can be found in most air ...

  3. Updating the OMERACT filter

    DEFF Research Database (Denmark)

    Tugwell, Peter; Boers, Maarten; D'Agostino, Maria-Antonietta

    2014-01-01

    OBJECTIVE: The Outcome Measures in Rheumatology (OMERACT) Filter provides guidelines for the development and validation of outcome measures for use in clinical research. The "Truth" section of the OMERACT Filter requires that criteria be met to demonstrate that the outcome instrument meets...... the criteria for content, face, and construct validity. METHODS: Discussion groups critically reviewed a variety of ways in which case studies of current OMERACT Working Groups complied with the Truth component of the Filter and what issues remained to be resolved. RESULTS: The case studies showed...... that there is broad agreement on criteria for meeting the Truth criteria through demonstration of content, face, and construct validity; however, several issues were identified that the Filter Working Group will need to address. CONCLUSION: These issues will require resolution to reach consensus on how Truth...

  4. Updating the OMERACT filter

    DEFF Research Database (Denmark)

    Kirwan, John R; Boers, Maarten; Hewlett, Sarah

    2014-01-01

    OBJECTIVE: The Outcome Measures in Rheumatology (OMERACT) Filter provides guidelines for the development and validation of outcome measures for use in clinical research. The "Truth" section of the OMERACT Filter presupposes an explicit framework for identifying the relevant core outcomes...... for defining core areas of measurement ("Filter 2.0 Core Areas of Measurement") was presented at OMERACT 11 to explore areas of consensus and to consider whether already endorsed core outcome sets fit into this newly proposed framework. METHODS: Discussion groups critically reviewed the extent to which case......, presentation, and clarity of the framework were questioned. The discussion groups and subsequent feedback highlighted 20 such issues. CONCLUSION: These issues will require resolution to reach consensus on accepting the proposed Filter 2.0 framework of Core Areas as the basis for the selection of Core Outcome...

  5. Paul Rodgersi filter Kohilas

    Index Scriptorium Estoniae

    2000-01-01

    28. I Kohila keskkoolis kohaspetsiifiline skulptuur ja performance "Filter". Kooli 130. aastapäeva tähistava ettevõtmise eesotsas oli skulptor Paul Rodgers ja kaks viimase klassi noormeest ئ Marko Heinmäe, Hendrik Karm.

  6. Perspectives on Nonlinear Filtering

    KAUST Repository

    Law, Kody

    2015-01-07

    The solution to the problem of nonlinear filtering may be given either as an estimate of the signal (and ideally some measure of concentration), or as a full posterior distribution. Similarly, one may evaluate the fidelity of the filter either by its ability to track the signal or its proximity to the posterior filtering distribution. Hence, the field enjoys a lively symbiosis between probability and control theory, and there are plenty of applications which benefit from algorithmic advances, from signal processing, to econometrics, to large-scale ocean, atmosphere, and climate modeling. This talk will survey some recent theoretical results involving accurate signal tracking with noise-free (degenerate) dynamics in high-dimensions (infinite, in principle, but say d between 103 and 108 , depending on the size of your application and your computer), and high-fidelity approximations of the filtering distribution in low dimensions (say d between 1 and several 10s).

  7. early functional outcome of distal femoral fractures at kenyatta

    African Journals Online (AJOL)

    The leading cause was RTA, followed by falls from a height. ... Distal femoral fractures cause considerable morbidity .... as means and standard deviations. .... Anaesthesia. Spinal. 37 (80). General Anaesthesia (GA). 9 (20). Transfusion.

  8. Subtrochanteric and Distal Femur Fractures in a Patient with ...

    African Journals Online (AJOL)

    This study reports the surgical management for this rare case and the treatment ... car accident and presented closed femoral shaft fracture associated with a ... to fix the distal femur fracture, enhancing the construction stability [Figures 4 and 5].

  9. Minimally invasive percutaneous plate fixation of distal tibia fractures.

    LENUS (Irish Health Repository)

    Bahari, Syah

    2007-10-01

    We report a series of 42 patients reviewed at a mean of 19.6 months after treatment of distal tibial and pilon fractures using the AO distal tibia locking plate with a minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. Mean time to union was 22.4 weeks. All fractures united with acceptable alignment and angulation. Two cases of superficial infection were noted, with one case of deep infection. Mean SF36 score was 85 and mean AOFAS score was 90 at a mean of 19 months follow-up. We report satisfactory outcomes with the use of the AO distal tibia locking plate in treatment of unstable distal tibial fractures. Eighty-nine percent of the patients felt that they were back to their pre injury status and 95% back to their previous employment.

  10. Surgical treatment of distal biceps tendon rupture: a case report

    Directory of Open Access Journals (Sweden)

    Cristina N. Cozma

    2017-11-01

    Full Text Available Objectives. Distal biceps tendon rupture affects the functional upperextremity movement, impairing supination and flexion strength. According to age, profession and additional risks treatment might be nonoperative or surgical. Methods. We describe the case of a 43 years old male patient who sustained an injury to his right distal biceps and was diagnosed with acute right distal biceps rupture. Surgical treatment was decided and biceps tendon was reinserted to the radius tuberosity using a combination of a cortical button fixation associated with an interference screw. Results. Postoperative functional result was favorable with no complications and with no movement limitation after one month. Conclusions. When possible, distal biceps tendon repair should be realized surgically because this permits restoring of the muscle strength to near normal levels with no loss of motion. Nerve complications are common; therefore the surgery should be realized by experienced upper extremity surgeons.

  11. Spatial filter issues

    International Nuclear Information System (INIS)

    Murray, J.E.; Estabrook, K.G.; Milam, D.; Sell, W.D.; Van Wonterghem, R.M.; Feil, M.D.; Rubenchick, A.M.

    1996-01-01

    Experiments and calculations indicate that the threshold pressure in spatial filters for distortion of a transmitted pulse scales approximately as I O.2 and (F number-sign) 2 over the intensity range from 10 14 to 2xlO 15 W/CM 2 . We also demonstrated an interferometric diagnostic that will be used to measure the scaling relationships governing pinhole closure in spatial filters

  12. Microwave Resonators and Filters

    Science.gov (United States)

    2015-12-22

    1 Microwave Resonators and Filters Daniel E. Oates MIT Lincoln Laboratory 244 Wood St. Lexington, MA 02478 USA Email: oates@ll.mit.edu...explained in other chapters, the surface resistance of superconductors at microwave frequencies can be as much as three orders of magnitude lower than the...resonators and filters in the first edition of this handbook (Z.-Y. Shen 2003) discussed the then state of the art of microwave frequency applications

  13. Staging with spatial filters

    International Nuclear Information System (INIS)

    Glaze, J.

    1974-01-01

    It is known that small scale beam instabilities limit the focusable energy that can be achieved from a terawatt laser chain. Spatial filters are currently being used on CYCLOPS to ameliorate this problem. Realizing the full advantage of such a filter, however, may require certain staging modifications. A staging methodology is discussed that should be applicable to the CYCLOPS, 381, and SHIVA systems. Experiments are in progress on CYCLOPS that will address directly the utility of the proposed approach

  14. Field test of radioactive high efficiency filter and filter exchange techniques of fuel cycle examination facility

    International Nuclear Information System (INIS)

    Hwang, Yong Hwa; Lee, Hyung Kwon; Chun, Young Bum; Park, Dae Gyu; Ahn, Sang Bok; Chu, Yong Sun; Kim, Eun Ka.

    1997-12-01

    The development of high efficiency filter was started to protect human beings from the contamination of radioactive particles, toxic gases and bacillus, and its gradual performance increment led to the fabrication of Ultra Low Penetration Air Filter (ULPA) today. The application field of ULPA has been spread not only to the air conditioning of nuclear power facilities, semiconductor industries, life science, optics, medical care and general facilities but also to the core of ultra-precision facilities. Periodic performance test on the filters is essential to extend its life-time through effective maintenance. Especially, the bank test on HEPA filter of nuclear facilities handling radioactive materials is required for environmental safety. Nowadays, the bank test technology has been reached to the utilization of a minimized portable detecting instruments and the evaluation techniques can provide high confidence in the area of particle distribution and leakage test efficiency. (author). 16 refs., 13 tabs., 14 figs

  15. Enclavado endomedular en fracturas del tercio distal de la tibia

    OpenAIRE

    Arroquy, Damian; Chahla, Jorge; Gomez Rodriguez, Gustavo; Cid Casteulani, Alberto; Svarzchtein, Santiago; Gomez, Diego; Pesciallo, Cesar

    2015-01-01

    Objetivo: Describir los resultados obtenidos con el enclavado endomedular acerrojado en pacientes con fractura del tercio distal de la tibia. Materiales y Métodos: Se incluyeron pacientes con fracturas desplazadas del tercio distal de la tibia, tratadas con clavo endomedular. La muestra incluyo 35 pacientes. El tiempo de seguimiento posoperatorio fue de 29.2 meses. Se evaluaron el tiempo de consolidacion, la consolidacion viciosa y las complicaciones. Los resultados funcionales se determinaro...

  16. Fractures of the Distal Tibia Treated with Polyaxial Locking Plating

    OpenAIRE

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2008-01-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial in...

  17. 40 CFR 86.1312-2007 - Filter stabilization and microbalance workstation environmental conditions, microbalance...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Filter stabilization and microbalance workstation environmental conditions, microbalance specifications, and particulate matter filter handling and... Particulate Exhaust Test Procedures § 86.1312-2007 Filter stabilization and microbalance workstation...

  18. Quantitative analysis and predictors of embolic filter debris load during carotid artery stenting in asymptomatic patients.

    Science.gov (United States)

    Piazza, Michele; Squizzato, Francesco; Chincarini, Chiara; Fedrigo, Marny; Castellani, Chiara; Angelini, Annalisa; Grego, Franco; Antonello, Michele

    2018-03-01

    The objective of this study was to perform a quantitative analysis and to identify predictors of embolic filter debris (EFD) load during carotid artery stenting (CAS) in asymptomatic patients. All patients with asymptomatic carotid stenosis >70% undergoing CAS between 2008 and 2016 were included in a prospective database. A distal filter protection device was used in all patients. At the end of the procedure, the filter was fixed in formalin and then analyzed with a stereomicroscope. Morphometric analysis was performed with Image-Pro Plus software (Media Cybernetics, Rockville, Md). The total area of the filter membrane and the area covered by particulate material were quantified. The quantity of membrane occupied by debris was expressed as percentage of covered surface area. Anatomic and clinical variables were evaluated for their association with EFD load using multiple logistic regression. Among the 278 patients undergoing CAS, an open-cell stent was implanted in 211 patients (76%); 67 patients (24%) received a closed-cell stent. Overall technical success and clinical success were both 99%; no perioperative death was reported. Stroke rate was 1.8% (major, n = 1 [0.4%]; minor, n = 4 [1.4%]); transient ischemic attacks occurred in 5% of cases (n = 14). The quantitative analysis of the filter revealed that EFD was present in 74% of cases (n = 207). The mean EFD load was 10% of the filter surface (median, 1; range, 0-80); it was 31% in 22 (8%). Patients with any type of ischemic neurologic event after CAS (stroke and transient ischemic attack) had a significantly higher mean EFD load compared with uneventful cases (26.7% ± 19.0% vs 8.5% ± 13.5%; P 12.5% EFD load as the optimal cutoff for the association with clinically relevant perioperative ischemic events (sensitivity, 78%; specificity, 77%; area under the curve, 0.81). The multivariate analysis demonstrated that age >75 years (odds ratio [OR], 2.56; P = .003), pre-existing ipsilateral ischemic

  19. Retinal protection from solar photic injury

    International Nuclear Information System (INIS)

    Chou, B.R.

    1981-01-01

    Samples of protective filters commonly used to observed the partially eclipsed sun were obtained and subjected to spectrophotometric analysis over the wavelength interval 330 to 2500 nm. Performance of these filters was compared with criteria for adequate ocular protection which have appeared in the literature. It appears that the greatest safety is provided by those devices incorporating a monatomic metallic coating as the filtering agent

  20. Preliminary Analytical Reviews on the Performance of Fibrous Filter

    International Nuclear Information System (INIS)

    Choi, Yu Jung; Hong, Tae Hyub; Kim, Hyeong-Taek

    2015-01-01

    The wet type Containment Filtered Vent System (CFVS) is composed of a tank including nozzles in a liquid pool, moisture separators, and a few dry filters such as a metal fiber filter and a molecular sieve. After injecting gases from the containment into the CFVS under severe accident conditions, the CFVS will release decontaminated radioactive materials to the environment. To protect against the release of uncontrolled fission products to the environment, we need to confirm the performance of the CFVS in terms of not only the integral capability but also the capabilities of the individual components. It is crucial to confirm the performance of the metal fiber filter in both analytical and experimental ways. Pressure drop across a filter and collection efficiency are ways to explain the performance of a fibrous filter. Based on data from the literature survey, pressure drop and collection efficiency for a single filter were calculated. The trends of pressure drop and collection efficiencies due to various deposition mechanisms of particles onto the fiber of the filters were roughly confirmed. Therefore, to obtain better quantitative predictions of the performance of the metal fiber filter, a new model able to evaluate the performance of fibrous filters under severe conditions should be developed

  1. The role of imaging in diagnosing diseases of the distal radioulnar joint, triangular fibrocartilage complex, and distal ulna.

    Science.gov (United States)

    Squires, Judy H; England, Eric; Mehta, Kaushal; Wissman, Robert D

    2014-07-01

    The purpose of this article is to review the anatomy, biomechanics, and multimodality imaging findings of common and uncommon distal radioulnar joint (DRUJ), triangular fibrocartilage complex, and distal ulna abnormalities. The DRUJ is a common site for acute and chronic injuries and is frequently imaged to evaluate chronic wrist pain, forearm dysfunction, and traumatic forearm injury. Given the complex anatomy of the wrist, the radiologist plays a vital role in the diagnosis of wrist pain and dysfunction.

  2. Volar plating for distal radius fractures--do not trust the image intensifier when judging distal subchondral screw length.

    Science.gov (United States)

    Park, Derek H; Goldie, Boyd S

    2012-09-01

    The use of the volar plate to treat distal radius fractures is increasing but despite the theoretical advantages of a volar approach there have been reports of extensor tendon ruptures due to prominent screw tips protruding past the dorsal cortex. The valley in the intermediate column between Lister tubercle and the sigmoid notch of the distal radius makes it difficult to rely on fluoroscopy to judge screw length. Our aim was to quantify the dimensions of this valley and to demonstrate the danger of relying on intraoperative image intensification fluoroscopy to determine lengths of distal screws. We measured the depth of this valley in the intermediate column of the distal radius in 33 patients with computed tomographic (9 patients) or magnetic resonance image (24 patients) scans of the wrist. There was a consistent valley in all images examined [average 1.8 mm (95% confidence interval, 1.6-2.0 mm)]. Thirty-nine percent of wrists had a valley depth of at least 2 mm. Standard lateral views or rotation of the forearm to obtain oblique views does not identify prominent screw tips; and whatever the rotation of the forearm, screw tips protruding beyond dorsal cortex may look as if it is within the bone when in fact it is out. When drilling we suggest noting the depth at which the drill bit just penetrates dorsal cortex and routinely downsize the distal screw length by 2 mm. We caution against relying on flourosocopy when judging the length of the distal subchondral screws.

  3. Choosing and using astronomical filters

    CERN Document Server

    Griffiths, Martin

    2014-01-01

    As a casual read through any of the major amateur astronomical magazines will demonstrate, there are filters available for all aspects of optical astronomy. This book provides a ready resource on the use of the following filters, among others, for observational astronomy or for imaging: Light pollution filters Planetary filters Solar filters Neutral density filters for Moon observation Deep-sky filters, for such objects as galaxies, nebulae and more Deep-sky objects can be imaged in much greater detail than was possible many years ago. Amateur astronomers can take

  4. Anti-clogging filter system

    Science.gov (United States)

    Brown, Erik P.

    2015-05-19

    An anti-clogging filter system for filtering a fluid containing large particles and small particles includes an enclosure with at least one individual elongated tubular filter element in the enclosure. The individual elongated tubular filter element has an internal passage, a closed end, an open end, and a filtering material in or on the individual elongated tubular filter element. The fluid travels through the open end of the elongated tubular element and through the internal passage and through the filtering material. An anti-clogging element is positioned on or adjacent the individual elongated tubular filter element and provides a fluid curtain that preferentially directs the larger particulates to one area of the filter material allowing the remainder of the filter material to remain more efficient.

  5. Multilevel ensemble Kalman filtering

    KAUST Repository

    Hoel, Haakon

    2016-01-08

    The ensemble Kalman filter (EnKF) is a sequential filtering method that uses an ensemble of particle paths to estimate the means and covariances required by the Kalman filter by the use of sample moments, i.e., the Monte Carlo method. EnKF is often both robust and efficient, but its performance may suffer in settings where the computational cost of accurate simulations of particles is high. The multilevel Monte Carlo method (MLMC) is an extension of classical Monte Carlo methods which by sampling stochastic realizations on a hierarchy of resolutions may reduce the computational cost of moment approximations by orders of magnitude. In this work we have combined the ideas of MLMC and EnKF to construct the multilevel ensemble Kalman filter (MLEnKF) for the setting of finite dimensional state and observation spaces. The main ideas of this method is to compute particle paths on a hierarchy of resolutions and to apply multilevel estimators on the ensemble hierarchy of particles to compute Kalman filter means and covariances. Theoretical results and a numerical study of the performance gains of MLEnKF over EnKF will be presented. Some ideas on the extension of MLEnKF to settings with infinite dimensional state spaces will also be presented.

  6. Multilevel ensemble Kalman filtering

    KAUST Repository

    Hoel, Haakon; Chernov, Alexey; Law, Kody; Nobile, Fabio; Tempone, Raul

    2016-01-01

    The ensemble Kalman filter (EnKF) is a sequential filtering method that uses an ensemble of particle paths to estimate the means and covariances required by the Kalman filter by the use of sample moments, i.e., the Monte Carlo method. EnKF is often both robust and efficient, but its performance may suffer in settings where the computational cost of accurate simulations of particles is high. The multilevel Monte Carlo method (MLMC) is an extension of classical Monte Carlo methods which by sampling stochastic realizations on a hierarchy of resolutions may reduce the computational cost of moment approximations by orders of magnitude. In this work we have combined the ideas of MLMC and EnKF to construct the multilevel ensemble Kalman filter (MLEnKF) for the setting of finite dimensional state and observation spaces. The main ideas of this method is to compute particle paths on a hierarchy of resolutions and to apply multilevel estimators on the ensemble hierarchy of particles to compute Kalman filter means and covariances. Theoretical results and a numerical study of the performance gains of MLEnKF over EnKF will be presented. Some ideas on the extension of MLEnKF to settings with infinite dimensional state spaces will also be presented.

  7. Arthroplasty of the distal ulna distal in managing patients with post-traumatic disorders of the distal radioulnar joint: measurement of quality of life

    Directory of Open Access Journals (Sweden)

    Marcio Aurélio Aita

    2015-12-01

    Full Text Available ABSTRACT OBJECTIVE: To measure the quality of life and clinical-functional results from patients diagnosed with osteoarthrosis of the distal radioulnar joint who underwent surgical treatment using the technique of total arthroplasty of the ulna, with a total or partial Ascension(r prosthesis of the distal ulna. METHODS: Ten patients were evaluated after 12 months of follow-up subsequent to total or partial arthroplasty of the distal ulna. All of them presented post-traumatic osteoarthrosis and/or chronic symptomatic instability of the distal radioulnar joint. The study was prospective. Seven patients had previously undergone wrist procedures (two cases with Darrach, three with Sauvé-Kapandji and two with ligament reconstruction of the fibrocartilage complex and three presented fractures of the distal ulna that evolved with pain, instability and osteoarthrosis of the distal radioulnar joint. The following were assessed: quality of life (DASH scale; percentage degree of palm grip strength (kgf and pronosupination range of motion in relation to the unaffected side; pain (VAS; return to work; subjective evaluation of radiography; and complications. RESULTS: The patients presented a mean range of motion of 174.5° (normal side: 180°. Quality of life was analyzed by applying the DASH questionnaire and the mean value found was 5.9. The mean pain score using the VAS was 2.3. The mean degree of palm grip strength (kgf was 50.7, which represented 90.7% of the strength on the unaffected side. The complication rate was 10%: this patient presented slight dorsal instability of the ulna and persistent pain, and did not return to work. This patient is still being followed up in the outpatient clinic and occupational therapy sector, with little improvement. He does not wish to undergo a new procedure. The mean length of follow-up was 16.8 months, with a minimum of 10 and maximum of 36 months. CONCLUSION: This concept is subject to the test of time

  8. Intake of specific nonfermented soy foods may be inversely associated with risk of distal gastric cancer in a Chinese population.

    Science.gov (United States)

    Kweon, Sun-Seog; Shu, Xiao-Ou; Xiang, Yongbing; Cai, Hui; Yang, Gong; Ji, Bu-Tian; Li, Honglan; Gao, Yu-Tang; Zheng, Wei; Epplein, Meira

    2013-11-01

    Because the association between soy consumption and gastric cancer is inconsistent, we evaluated the putative preventive effect of soy food on gastric cancer risk in the Shanghai Women's and Men's Health Studies, comprising a total of 128,687 participants. Intake of nonfermented soy foods was estimated using 2 validated food-frequency questionnaires. HRs were calculated with 95% CIs for intake amounts of total nonfermented soy food intake, soy protein, and isoflavones as well as individual soy food groups using Cox proportional hazards regression. A total of 493 distal gastric cancer cases were identified by 2010. Although all risk estimates for summary measures of soy food intake above the lowest quartile (quartile 1) were suggestive of a protective effect, no statistically significant associations with risk of distal gastric cancer were found. Among the separate soy food groups, significant reductions in risk of distal gastric cancer by increasing intake of tofu were found in men in quartile 2 (HR: 0.59; 95% CI: 0.40, 0.86), quartile 3 (HR: 0.62; 95% CI: 0.44, 0.88), and quartile 4 (HR: 0.64; 95% CI: 0.42, 0.99), resulting in a significant trend (P-trend = 0.02). Dry bean intake was also inversely associated with decreased risk of gastric cancer, but in postmenopausal women only [quartile 2 (HR: 0.54; 95% CI: 0.30, 0.96); quartile 3 (HR: 0.90; 95% CI: 0.64, 1.27); and quartile 4 (HR: 0.63; 95% CI: 0.43, 0.91)], resulting in a significant trend (P-trend = 0.03). Overall, our study found no statistically significant association between nonfermented soy food intake and distal gastric cancer risk, though the data supported the hypothesis that tofu may protect against distal gastric cancer in men and dry bean consumption may decrease the risk of gastric cancer in postmenopausal women.

  9. IVC filter limb penetration of the caval wall during retroperitoneal surgery/lymph node dissection.

    LENUS (Irish Health Repository)

    Goh, Gerard S

    2012-12-01

    Optional inferior vena cava (IVC) filters are being increasingly used for protection against pulmonary embolism in patients with deep vein thrombosis where anticoagulation is contraindicated. We describe two cases during retroperitoneal surgery where the IVC filters were found to have perforated the cava wall and were subsequently removed intra-operatively. Cava wall penetration by filter limbs poses a significant danger during retroperitoneal lymph node dissection and filters should be removed preoperatively.

  10. Adaptive digital filters

    CERN Document Server

    Kovačević, Branko; Milosavljević, Milan

    2013-01-01

    “Adaptive Digital Filters” presents an important discipline applied to the domain of speech processing. The book first makes the reader acquainted with the basic terms of filtering and adaptive filtering, before introducing the field of advanced modern algorithms, some of which are contributed by the authors themselves. Working in the field of adaptive signal processing requires the use of complex mathematical tools. The book offers a detailed presentation of the mathematical models that is clear and consistent, an approach that allows everyone with a college level of mathematics knowledge to successfully follow the mathematical derivations and descriptions of algorithms.   The algorithms are presented in flow charts, which facilitates their practical implementation. The book presents many experimental results and treats the aspects of practical application of adaptive filtering in real systems, making it a valuable resource for both undergraduate and graduate students, and for all others interested in m...

  11. Updating the OMERACT filter

    DEFF Research Database (Denmark)

    D'Agostino, Maria-Antonietta; Boers, Maarten; Kirwan, John

    2014-01-01

    OBJECTIVE: The Outcome Measures in Rheumatology (OMERACT) Filter provides a framework for the validation of outcome measures for use in rheumatology clinical research. However, imaging and biochemical measures may face additional validation challenges because of their technical nature. The Imaging...... using the original OMERACT Filter and the newly proposed structure. Breakout groups critically reviewed the extent to which the candidate biomarkers complied with the proposed stepwise approach, as a way of examining the utility of the proposed 3-dimensional structure. RESULTS: Although...... was obtained for a proposed tri-axis structure to assess validation of imaging and soluble biomarkers; nevertheless, additional work is required to better evaluate its place within the OMERACT Filter 2.0....

  12. Automated electronic filter design

    CERN Document Server

    Banerjee, Amal

    2017-01-01

    This book describes a novel, efficient and powerful scheme for designing and evaluating the performance characteristics of any electronic filter designed with predefined specifications. The author explains techniques that enable readers to eliminate complicated manual, and thus error-prone and time-consuming, steps of traditional design techniques. The presentation includes demonstration of efficient automation, using an ANSI C language program, which accepts any filter design specification (e.g. Chebyschev low-pass filter, cut-off frequency, pass-band ripple etc.) as input and generates as output a SPICE(Simulation Program with Integrated Circuit Emphasis) format netlist. Readers then can use this netlist to run simulations with any version of the popular SPICE simulator, increasing accuracy of the final results, without violating any of the key principles of the traditional design scheme.

  13. Stack filter classifiers

    Energy Technology Data Exchange (ETDEWEB)

    Porter, Reid B [Los Alamos National Laboratory; Hush, Don [Los Alamos National Laboratory

    2009-01-01

    Just as linear models generalize the sample mean and weighted average, weighted order statistic models generalize the sample median and weighted median. This analogy can be continued informally to generalized additive modeels in the case of the mean, and Stack Filters in the case of the median. Both of these model classes have been extensively studied for signal and image processing but it is surprising to find that for pattern classification, their treatment has been significantly one sided. Generalized additive models are now a major tool in pattern classification and many different learning algorithms have been developed to fit model parameters to finite data. However Stack Filters remain largely confined to signal and image processing and learning algorithms for classification are yet to be seen. This paper is a step towards Stack Filter Classifiers and it shows that the approach is interesting from both a theoretical and a practical perspective.

  14. Quantum reality filters

    International Nuclear Information System (INIS)

    Gudder, Stan

    2010-01-01

    An anhomomorphic logic A* is the set of all possible realities for a quantum system. Our main goal is to find the 'actual reality' Φ a element of A* for the system. Reality filters are employed to eliminate unwanted potential realities until only φ a remains. In this paper, we consider three reality filters that are constructed by means of quantum integrals. A quantum measure μ can generate or actualize a Φ element of A* if μ(A) is a quantum integral with respect to φ for a density function f over events A. In this sense, μ is an 'average' of the truth values of φ with weights given by f. We mainly discuss relations between these filters and their existence and uniqueness properties. For example, we show that a quadratic reality generated by a quantum measure is unique. In this case we obtain the unique actual quadratic reality.

  15. Ex-vivo release of Pipeline Embolization Device polytetrafluoroethylene (PTFE) sleeves for improved distal landing zone accuracy in-vivo: A technical note.

    Science.gov (United States)

    Griessenauer, Christoph J; Gupta, Raghav; Moore, Justin; Thomas, Ajith J; Ogilvy, Christopher S

    2016-12-01

    Distal landing zone accuracy is critical in some intracranial aneurysms treated with the Pipeline Embolization Device (PED), and delayed opening of the distal end of the device can complicate the procedure. Here, we report a technical nuance that facilitates accurate placement of the distal end of the PED by ex-vivo, pre-implantation release of the PED Flex polytetrafluoroethylene (PTFE) sleeves. The PED Flex is partially pushed out of the introducer sheath ex-vivo, pre-implantation until the distal PED opens entirely and the PTFE sleeves are located distal to the device. Without inverting the PTFE sleeves, the PED is carefully pulled back into the introducer sheath placing the PTFE sleeves inside the device. The PED is loaded into the microcatheter and advanced toward the site of implantation. When the PED is initially deployed and pushed out of the microcatheter, it opens immediately and provides an anchor for the remainder of the deployment process. We present a video (supplementary material) that illustrates the technique along with an illustrative case. Ex-vivo, pre-implantation release of the PTFE sleeves is an option in aneurysm treatment where distal landing accuracy is critical. Even without the protection of the PTFE sleeves, our clinical observation shows that the PED can be advanced safely through the microcatheter in selected cases. © The Author(s) 2016.

  16. Filters in topology optimization

    DEFF Research Database (Denmark)

    Bourdin, Blaise

    1999-01-01

    In this article, a modified (``filtered'') version of the minimum compliance topology optimization problem is studied. The direct dependence of the material properties on its pointwise density is replaced by a regularization of the density field using a convolution operator. In this setting...... it is possible to establish the existence of solutions. Moreover, convergence of an approximation by means of finite elements can be obtained. This is illustrated through some numerical experiments. The ``filtering'' technique is also shown to cope with two important numerical problems in topology optimization...

  17. Alarm filtering and presentation

    International Nuclear Information System (INIS)

    Bray, M.A.

    1989-01-01

    This paper discusses alarm filtering and presentation in the control room of nuclear and other process control plants. Alarm generation and presentation is widely recognized as a general process control problem. Alarm systems often fail to provide meaningful alarms to operators. Alarm generation and presentation is an area in which computer aiding is feasible and provides clear benefits. Therefore, researchers have developed several computerized alarm filtering and presentation approaches. This paper discusses problems associated with alarm generation and presentation. Approaches to improving the alarm situation and installation issues of alarm system improvements are discussed. The impact of artificial intelligence (AI) technology on alarm system improvements is assessed. (orig.)

  18. A New Orthodontic Appliance with a Mini Screw for Upper Molar Distalization.

    Science.gov (United States)

    Ozkalayci, Nurhat; Yetmez, Mehmet

    2016-01-01

    The aim of this study is to present a new upper molar distalization appliance called Cise distalizer designed as intraoral device supported with orthodontic mini screw for upper permanent molar distalization. The new appliance consists of eight main components. In order to understand the optimum force level, the appliance under static loading is tested by using strain gage measurement techniques. Results show that one of the open coils produces approximately 300 gr distalization force. Cise distalizer can provide totally 600 gr distalization force. This range of force level is enough for distalization of upper first and second molar teeth.

  19. A New Orthodontic Appliance with a Mini Screw for Upper Molar Distalization

    Directory of Open Access Journals (Sweden)

    Nurhat Ozkalayci

    2016-01-01

    Full Text Available The aim of this study is to present a new upper molar distalization appliance called Cise distalizer designed as intraoral device supported with orthodontic mini screw for upper permanent molar distalization. The new appliance consists of eight main components. In order to understand the optimum force level, the appliance under static loading is tested by using strain gage measurement techniques. Results show that one of the open coils produces approximately 300 gr distalization force. Cise distalizer can provide totally 600 gr distalization force. This range of force level is enough for distalization of upper first and second molar teeth.

  20. Limited distal organelles and synaptic function in extensive monoaminergic innervation.

    Science.gov (United States)

    Tao, Juan; Bulgari, Dinara; Deitcher, David L; Levitan, Edwin S

    2017-08-01

    Organelles such as neuropeptide-containing dense-core vesicles (DCVs) and mitochondria travel down axons to supply synaptic boutons. DCV distribution among en passant boutons in small axonal arbors is mediated by circulation with bidirectional capture. However, it is not known how organelles are distributed in extensive arbors associated with mammalian dopamine neuron vulnerability, and with volume transmission and neuromodulation by monoamines and neuropeptides. Therefore, we studied presynaptic organelle distribution in Drosophila octopamine neurons that innervate ∼20 muscles with ∼1500 boutons. Unlike in smaller arbors, distal boutons in these arbors contain fewer DCVs and mitochondria, although active zones are present. Absence of vesicle circulation is evident by proximal nascent DCV delivery, limited impact of retrograde transport and older distal DCVs. Traffic studies show that DCV axonal transport and synaptic capture are not scaled for extensive innervation, thus limiting distal delivery. Activity-induced synaptic endocytosis and synaptic neuropeptide release are also reduced distally. We propose that limits in organelle transport and synaptic capture compromise distal synapse maintenance and function in extensive axonal arbors, thereby affecting development, plasticity and vulnerability to neurodegenerative disease. © 2017. Published by The Company of Biologists Ltd.

  1. Fractures of the distal radius in children: A retrospective evaluation

    Directory of Open Access Journals (Sweden)

    Selma Yazıcı

    2012-06-01

    Full Text Available Objectives: This study designed to evaluate the resultsof treatment, closed reduction and percutaneous wires, ofthe distal radius fractures in children.Materials and methods: A retrospective analysis wascarried out in children aged between 5-15 years who presentedwith a displaced fracture of the distal radius to ourhospital. They were initially treated with closed reductionand cast immobilization. If the fractures redisplaced treatedby percutaneous Kirschner (K- wire with scope undera general anaesthesia.Results: Totally 104 patients, who have distal radius fractureswere treated by closed reduction and immobilizationin a plaster cast. 13 patient who have distal radiusfractures were treated by closed reduction under generalanaesthesia and fixed by percutaneous Kirschner (K-wire. Patients with impaired the alignment of the fracturein late period were usually completely displaced fractures.(n=5, 4,3%, in early period, completely displaced fractures(n=5, 4,3% are superior to partial displaced fractures(n=2, 1,7%.Conclusion: In our study, when children with distal radiusfracture first come, they were treated by closed reductionand immobilization in a plaster cast. We thought that inredisplaced fractures patients were suitable for the closedreduction with percutaneous wire treatment.

  2. Laparoscopic versus open distal pancreatectomy for pancreatic cancer.

    Science.gov (United States)

    Riviere, Deniece; Gurusamy, Kurinchi Selvan; Kooby, David A; Vollmer, Charles M; Besselink, Marc G H; Davidson, Brian R; van Laarhoven, Cornelis J H M

    2016-04-04

    Surgical resection is currently the only treatment with the potential for long-term survival and cure of pancreatic cancer. Surgical resection is provided as distal pancreatectomy for cancers of the body and tail of the pancreas. It can be performed by laparoscopic or open surgery. In operations on other organs, laparoscopic surgery has been shown to reduce complications and length of hospital stay as compared with open surgery. However, concerns remain about the safety of laparoscopic distal pancreatectomy compared with open distal pancreatectomy in terms of postoperative complications and oncological clearance. To assess the benefits and harms of laparoscopic distal pancreatectomy versus open distal pancreatectomy for people undergoing distal pancreatectomy for pancreatic ductal adenocarcinoma of the body or tail of the pancreas, or both. We used search strategies to search the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, Science Citation Index Expanded and trials registers until June 2015 to identify randomised controlled trials (RCTs) and non-randomised studies. We also searched the reference lists of included trials to identify additional studies. We considered for inclusion in the review RCTs and non-randomised studies comparing laparoscopic versus open distal pancreatectomy in patients with resectable pancreatic cancer, irrespective of language, blinding or publication status.. Two review authors independently identified trials and independently extracted data. We calculated odds ratios (ORs), mean differences (MDs) or hazard ratios (HRs) along with 95% confidence intervals (CIs) using both fixed-effect and random-effects models with RevMan 5 on the basis of intention-to-treat analysis when possible. We found no RCTs on this topic. We included in this review 12 non-randomised studies that compared laparoscopic versus open distal pancreatectomy (1576 participants: 394 underwent laparoscopic distal pancreatectomy and 1182

  3. Statistically-Efficient Filtering in Impulsive Environments: Weighted Myriad Filters

    Directory of Open Access Journals (Sweden)

    Juan G. Gonzalez

    2002-01-01

    Full Text Available Linear filtering theory has been largely motivated by the characteristics of Gaussian signals. In the same manner, the proposed Myriad Filtering methods are motivated by the need for a flexible filter class with high statistical efficiency in non-Gaussian impulsive environments that can appear in practice. Myriad filters have a solid theoretical basis, are inherently more powerful than median filters, and are very general, subsuming traditional linear FIR filters. The foundation of the proposed filtering algorithms lies in the definition of the myriad as a tunable estimator of location derived from the theory of robust statistics. We prove several fundamental properties of this estimator and show its optimality in practical impulsive models such as the α-stable and generalized-t. We then extend the myriad estimation framework to allow the use of weights. In the same way as linear FIR filters become a powerful generalization of the mean filter, filters based on running myriads reach all of their potential when a weighting scheme is utilized. We derive the “normal” equations for the optimal myriad filter, and introduce a suboptimal methodology for filter tuning and design. The strong potential of myriad filtering and estimation in impulsive environments is illustrated with several examples.

  4. Giant Cell Tumour of the Distal Ulna: A Rare Presentation

    Directory of Open Access Journals (Sweden)

    Ruben Jaya Kumar

    2011-07-01

    Full Text Available Giant-cell tumour (GCT of bone, a primary yet locally aggressive benign tumour, commonly affects patients between the ages of 20 and 40 years, with the peak incidence occurring in the third decade. Women are affected slightly more than men. The distal end of the ulna is an extremely uncommon site for primary bone tumours in general and giant cell tumours in particular. Wide resection of the distal ulna is the recommended treatment for GCT in such locations. Radio-ulna convergence and dorsal displacement of the ulna stump are known complications following ulna resection proximal to the insertion of the pronator quadratus. This leads to reduction in grip power and forearm rotatory motion. Stabilization of the ulna stump with extensor carpi ulnaris (ECU tendon after wide resection of the tumour has been described in the literature. We report a case of GCT of distal end of ulna treated with wide resection and stabilization with ECU tendon.

  5. Segmental reversal of distal small intestine in short bowel syndrome

    DEFF Research Database (Denmark)

    Grave, Pernille Kock; Thomsen, Sabrina Valentin; Clark, Pia Susanne

    2018-01-01

    were the influence on cell proliferation and mucosal architecture shown by histological analysis. Methods: Sixteen piglets underwent a 60% resection of the distal small intestine and were randomized into two groups. Group 1 short bowel syndrome alone (SBS) (n = 8) and group 2 with reversal of a distal...... small intestinal segment (SBS-RS) (n = 8). Body weight was measured daily and the pigs were euthanized after 1 month. Crypt depths, villus heights and muscle layers thicknesses were measured. For the evaluation of microvilli of the brush border of the epithelium and cell proliferation...... was found in the SBS group and increase in the thickness of the circular and longitudinal muscle layers in the SBS-RS group. In the distal ileal segment the longitudinal muscle layer thicknesses were increased in the SBS group. Otherwise, no significant changes were found. Conclusion: Reversal of a 20-cm...

  6. Fractures of the distal tibia treated with polyaxial locking plating.

    Science.gov (United States)

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2009-03-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial infections and evidence of delayed wound healing. Using the American Orthopaedic Foot and Ankle Society ankle score, the average functional score was 87.3 points (of 100 total possible points). Our results show the polyaxial locking plates, which offer more fixation versatility, may be a reasonable treatment option for distal tibia fractures with very short metaphyseal segments.

  7. The ATLAS event filter

    CERN Document Server

    Beck, H P; Boissat, C; Davis, R; Duval, P Y; Etienne, F; Fede, E; Francis, D; Green, P; Hemmer, F; Jones, R; MacKinnon, J; Mapelli, Livio P; Meessen, C; Mommsen, R K; Mornacchi, Giuseppe; Nacasch, R; Negri, A; Pinfold, James L; Polesello, G; Qian, Z; Rafflin, C; Scannicchio, D A; Stanescu, C; Touchard, F; Vercesi, V

    1999-01-01

    An overview of the studies for the ATLAS Event Filter is given. The architecture and the high level design of the DAQ-1 prototype is presented. The current status if the prototypes is briefly given. Finally, future plans and milestones are given. (11 refs).

  8. Spectral Ensemble Kalman Filters

    Czech Academy of Sciences Publication Activity Database

    Mandel, Jan; Kasanický, Ivan; Vejmelka, Martin; Fuglík, Viktor; Turčičová, Marie; Eben, Kryštof; Resler, Jaroslav; Juruš, Pavel

    2014-01-01

    Roč. 11, - (2014), EMS2014-446 [EMS Annual Meeting /14./ & European Conference on Applied Climatology (ECAC) /10./. 06.10.2014-10.10.2014, Prague] R&D Projects: GA ČR GA13-34856S Grant - others:NSF DMS-1216481 Institutional support: RVO:67985807 Keywords : data assimilation * spectral filter Subject RIV: DG - Athmosphere Sciences, Meteorology

  9. Minimally Invasive Distal Pancreatectomy: Review of the English Literature.

    Science.gov (United States)

    Wang, Kai; Fan, Ying

    2017-02-01

    Recently, the superiority of the minimally invasive approach, which results in a better cosmetic result, faster recovery, and shorter length of hospital stay, is a technique that has been progressively recognized as it has developed. And the minimally invasive approach has been applied to distal pancreatectomy (DP), which is a standard method for the treatment of benign, borderline, and part of malignant lesions of the pancreatic body and tail. This article aims to analyze the types, postoperative recovery, and outcomes of laparoscopic distal pancreatectomy (LDP). A systematic search of the scientific literature was performed using PubMed, EMBASE, online journals, and the Internet for all publications on LDP. Articles were selected if the abstract contained patients who underwent LDP for pancreatic diseases. All selected articles were reviewed and analyzed. If there were no contraindications for LDP, this operation is suitable for benign, borderline, or malignant tumors of the pancreatic body and tail, which should try to be performed with preservation of the spleen. LDP is safe and feasible under some conditions to experienced surgeon. Single-incision laparoscopic distal pancreatectomy (S-LDP) and robotic laparoscopic distal pancreatectomy (R-LDP) perioperative outcomes are similar with conventional multi-incision laparoscopic distal pancreatectomy (C-LDP). And the advantages of S-LDP and R-LDP require further exploration. With the application of enhanced recovery program (ERP), length of hospital stay and costs are reduced. LDP is safe and feasible under some conditions. Compared with open distal pancreatectomy, LDP has a lot of advantages; a trend was observed for LDP to replace traditional open surgery. LDP combined with ERP is expected to become standard in the treatment of pancreatic body and tail lesions.

  10. Laparoscopic distal pancreatectomy for adenocarcinoma: safe and reasonable?

    Science.gov (United States)

    Postlewait, Lauren M.

    2015-01-01

    As a result of technological advances during the past two decades, surgeons now use minimally invasive surgery (MIS) approaches to pancreatic resection more frequently, yet the role of these approaches for pancreatic ductal adenocarcinoma resections remains uncertain, given the aggressive nature of this malignancy. Although there are no controlled trials comparing MIS technique to open surgical technique, laparoscopic distal pancreatectomy for pancreatic adenocarcinoma is performed with increasing frequency. Data from retrospective studies suggest that perioperative complication profiles between open and laparoscopic distal pancreatectomy are similar, with perhaps lower blood loss and fewer wound infections in the MIS group. Concerning oncologic outcomes, there appear to be no differences in the rate of achieving negative margins or in the number of lymph nodes (LNs) resected when compared to open surgery. There are limited recurrence and survival data on laparoscopic compared to open distal pancreatectomy for pancreatic adenocarcinoma, but in the few studies that assess long term outcomes, recurrence rates and survival outcomes appear similar. Recent studies show that though laparoscopic distal pancreatectomy entails a greater operative cost, the associated shorter length of hospital stay leads to decreased overall cost compared to open procedures. Multiple new technologies are emerging to improve resection of pancreatic cancer. Robotic pancreatectomy is feasible, but there are limited data on robotic resection of pancreatic adenocarcinoma, and outcomes appear similar to laparoscopic approaches. Additionally fluorescence-guided surgery represents a new technology on the horizon that could improve oncologic outcomes after resection of pancreatic adenocarcinoma, though published data thus far are limited to animal models. Overall, MIS distal pancreatectomy appears to be a safe and reasonable approach to treating selected patients with pancreatic ductal

  11. DEMONSTRATION BULLETIN: COLLOID POLISHING FILTER METHOD - FILTER FLOW TECHNOLOGY, INC.

    Science.gov (United States)

    The Filter Flow Technology, Inc. (FFT) Colloid Polishing Filter Method (CPFM) was tested as a transportable, trailer mounted, system that uses sorption and chemical complexing phenomena to remove heavy metals and nontritium radionuclides from water. Contaminated waters can be pro...

  12. Filter assembly for metallic and intermetallic tube filters

    Science.gov (United States)

    Alvin, Mary Anne; Lippert, Thomas E.; Bruck, Gerald J.; Smeltzer, Eugene E.

    2001-01-01

    A filter assembly (60) for holding a filter element (28) within a hot gas cleanup system pressure vessel is provided, containing: a filter housing (62), said filter housing having a certain axial length and having a peripheral sidewall, said sidewall defining an interior chamber (66); a one piece, all metal, fail-safe/regenerator device (68) within the interior chamber (66) of the filter housing (62) and/or extending beyond the axial length of the filter housing, said device containing an outward extending radial flange (71) within the filter housing for seating an essential seal (70), the device also having heat transfer media (72) disposed inside and screens (80) for particulate removal; one compliant gasket (70) positioned next to and above the outward extending radial flange of the fail-safe/regenerator device; and a porous metallic corrosion resistant superalloy type filter element body welded at the bottom of the metal fail-safe/regenerator device.

  13. Digital Simulation of a Hybrid Active Filter - An Active Filter in Series with a Shunt Passive Filter

    OpenAIRE

    Sitaram, Mahesh I; Padiyar, KR; Ramanarayanan, V

    1998-01-01

    Active filters have long been in use for the filtering of power system load harmonics. In this paper, the digital simulation results of a hybrid active power filter system for a rectifier load are presented. The active filter is used for filtering higher order harmonics as the dominant harmonics are filtered by the passive filter. This reduces the rating of the active filter significantly. The DC capacitor voltage of the active filter is controlled using a PI controller.

  14. Neglected Distal Humeral Epiphyseal Injury - Two Case Reports

    Directory of Open Access Journals (Sweden)

    Dr. Pankaj Kumar

    2008-07-01

    Full Text Available Distal humeral epiphyseal separation is an uncommon injury in children, which can be missed or misdiagnosed at initial presentation. Awareness of this injury and appropriate radiological assessment helps in proper management. Neglected cases because of inappropriate diagnosis can result in cubitus varus deformity. Full range of movements of elbow can be achieved if properly diagnosed and managed. We present two cases of neglected distal humeral epiphyseal injury in children that resulted in cubitus varus deformity in one case. Full range of movements was achieved in both cases after proper management.

  15. Distal vertebral artery reconstruction when managing vertebrobasilar insufficiency

    Directory of Open Access Journals (Sweden)

    D. M. Galaktionov

    2017-11-01

    Full Text Available This article presents a literature review devoted to the reconstruction of the distal vertebral artery and a clinical case of successful surgical treatment of a patient suffering from vertebrobasilar insufficiency caused by occlusion of the vertebral artery in a proximal segment. The external carotid artery-distal vertebral artery bypass was performed by using the radial artery.Received 27 February 2017. Revised 25 July 2017. Accepted 3 August 2017.Funding: The study did not have sponsorship.Conflict of interest: The authors declare no conflict of interest. 

  16. Robotic spleen-preserving distal pancreatectomy. A case report.

    Science.gov (United States)

    Vasilescu, C; Sgarbura, O; Tudor, S; Herlea, V; Popescu, I

    2009-01-01

    Distal pancreatectomy (DP) is the removal of the pancreatic tissue at the left side of the superior mesenteric vein and it is traditionally approached by an open or laparoscopic exposure. Preservation of the spleen is optional but appears to have a better immunological outcome. We present the case of a 53-year old patient with a 2.4/2.2 tumor located in the tail of the pancreas, with high tumour marker values for whom we decided to perform a robotic spleen-preserving distal pancreatectomy (RSPDP). The postoperative outcome was satisfactory. In conclusion, we recommend this type of approach for small pancreatic tail lesions.

  17. Locking plates in distal humerus fractures: study of 43 patients

    Directory of Open Access Journals (Sweden)

    Gupta Rakesh Kumar

    2013-08-01

    Full Text Available 【Abstract】Objective: The treatment of multi-fragmentary, intraarticular fractures of the distal humerus is difficult, even in young patients with bone of good quality. Small distal fragment, diminished bone mineral quality and increased trauma-associated joint destruction make stable joint reconstruction more problematic. The anatomically preshaped locking plates allow angular stable fixation for these complex fractures. We evaluated functional results of patients treated with open reduction and internal fixation with distal humerus locking plates for complex distal hu-merus fractures. Methods: Forty-three consecutive patients with ar-ticular fractures of the distal humerus were treated by open reduction and internal fixation with AO distal humerus plate system and locking reconstruction plates. Forty patients were available for the final outcome analysis. According to AO/ASIF classification, there were 2 cases of type A2, 4 cases of type A3, 1 case of type B1, 1 case of type B2, 14 cases of type C1, 7 cases of type C2 and 11 cases of type C3. Open reduction with triceps splitting technique was used in all patients. The clinical and radiographic follow-up was performed and outcome measures included pain assessment, range of motion, and Mayo elbow performance score. Results: Forty patients were available for the final outcome analysis. There were 29 males and 11 females with an average age of 38.4 years (18-73 years. Clinical and ra-diological consolidation of the fracture was observed in all cases at an average of 11.6 weeks (9-14 weeks. The average follow-up was 12 months (10-18 months. Using the Mayo elbow performance score the results obtained were graded as excellent or good results in 33 patients (82.5%. One pa-tient had superficial infection, and 4 had myositis ossificans. There were no cases of primary malposition or secondary displacement, implant failure or ulnar neuropathy. Conclusion: Anatomically preshaped distal humerus locking

  18. Traumatisk distal humerus-epifysiolyse hos nyfødt

    DEFF Research Database (Denmark)

    Al-Aubaidi, Zaid; Nielsen, Keld Daubjerg

    2010-01-01

    Traumatic distal humerus epiphysiolysis (TDHE) is a rare injury in infants with an incidence of about 1:35,000 births. It is primarily a birth injury, but it is also seen in cases of battered child syndrome. Because of its rare occurrence and the diagnostic difficulties, the lesion may be overloo......Traumatic distal humerus epiphysiolysis (TDHE) is a rare injury in infants with an incidence of about 1:35,000 births. It is primarily a birth injury, but it is also seen in cases of battered child syndrome. Because of its rare occurrence and the diagnostic difficulties, the lesion may...

  19. Primary bone lymphoma of the distal tibia mimicking brodie's abscess

    International Nuclear Information System (INIS)

    Park, Jina; Lee, Seung Hun; Joo, Kyung Bin; Park, Chan Kum

    2014-01-01

    The 'penumbra sign' on an unenhanced T1-weighted image is a well-known characteristic of Brodie's abscess, and this sign is extremely helpful for discriminating subacute osteomyelitis from other bone lesions. We present a case of primary bone lymphoma of the distal tibia mimicking subacute osteomyelitis with Brodie's abscess in a 50-year-old woman. Initial radiographs and MRI showed a lesion in the distal tibia consistent with Brodie's abscess with the penumbra sign. Histopathological examination of the surgical biopsy specimen confirmed the presence of a diffuse large B-cell lymphoma involving the bone.

  20. Nontraumatic osteonecrosis of the distal pole of the scaphoid

    Directory of Open Access Journals (Sweden)

    Bhavuk Garg

    2011-01-01

    Full Text Available Post traumatic osteonecrosis of distal pole of scaphoid is very rare. We present a case of 34 years old male, drill operator by occupation with nontraumatic osteonecrosis of distal pole of the scaphoid. The patient was managed conservatively and was kept under regular follow-up every three months. The patient was also asked to change his profession. Two years later, the patient had no pain and had mild restriction of wrist movements (less than 15 degrees in either direction. The radiographs revealed normal density of the scaphoid suggesting revascularization.

  1. Osteoblastoma-like osteosarcoma of the distal tibia

    Energy Technology Data Exchange (ETDEWEB)

    Abramovici, Luigia; Steiner, German C. [Department of Pathology and Laboratory Medicine, Hospital for Joint Diseases, New York, NY (United States); Kenan, Samuel [Department of Orthopaedic Oncology Surgery, Hospital for Joint Diseases, New York, NY (United States); Hytiroglou, Prodromos [Aristotle University, Thessaloniki (Greece); Rafii, Mahvash [Department of Radiology, Hospital for Joint Diseases, New York, NY (United States)

    2002-03-01

    We report a case of a 14-year-old boy with an intracompartmental lytic lesion with poorly defined margins in the right distal tibia that was originally treated with curettage and bone grafting. Histologic examination showed an osteoblastic tumor with unusual features, which was found on consultation to be an osteoblastoma-like osteosarcoma, a rare, low-grade variant of osteosarcoma. Subsequently, the patient underwent en bloc resection of the distal tibia, which was replaced with vascularized bone graft and followed by chemotherapy. Two years later, he is alive with lung metastases. (orig.)

  2. Osteoblastoma-like osteosarcoma of the distal tibia

    International Nuclear Information System (INIS)

    Abramovici, Luigia; Steiner, German C.; Kenan, Samuel; Hytiroglou, Prodromos; Rafii, Mahvash

    2002-01-01

    We report a case of a 14-year-old boy with an intracompartmental lytic lesion with poorly defined margins in the right distal tibia that was originally treated with curettage and bone grafting. Histologic examination showed an osteoblastic tumor with unusual features, which was found on consultation to be an osteoblastoma-like osteosarcoma, a rare, low-grade variant of osteosarcoma. Subsequently, the patient underwent en bloc resection of the distal tibia, which was replaced with vascularized bone graft and followed by chemotherapy. Two years later, he is alive with lung metastases. (orig.)

  3. Distal renal tubular acidosis and amelogenesis imperfecta: A rare association

    Directory of Open Access Journals (Sweden)

    P Ravi

    2013-01-01

    Full Text Available Renal tubular acidosis (RTA is characterized by a normal anion gap with hyperchloremic metabolic acidosis. Primary distal RTA (type I is the most common RTA in children. Childhood presentation of distal RTA includes vomiting, failure to thrive, metabolic acidosis, and hypokalemia. Amelogenesis imperfecta (AI represents a condition where the dental enamel and oral tissues are affected in an equal manner resulting in the hypoplastic or hypopigmented teeth. We report a 10-year-old girl, previously asymptomatic presented with the hypokalemic paralysis and on work-up found out to have type I RTA. The discoloration of teeth and enamel was diagnosed as AI.

  4. Modified distal shoe appliance--fabrication and clinical performance.

    Science.gov (United States)

    Gujjar, Kumar Raghav; Indushekar, K R; Amith, H V; Sharma, Shefali Li

    2012-01-01

    When the primary second molar is prematurely lost, mesial movement and migration of the permanent first molar often occurs. This is one of the most difficult problems of the developing dentition confronted by pediatric dentists. Use of a space maintainer that will guide the permanent first molar into its normal position is indicated. In cases with bilateral premature loss of primary molars, the conventional design of distal shoe poses a variety of problems and, therefore, necessitates a customized design for the eruption guidance of permanent first molars. The purpose of this case report is to discuss an innovative design of a distal shoe appliance, which was used with good clinical results.

  5. Screening renal stone formers for distal renal tubular acidosis

    DEFF Research Database (Denmark)

    Osther, P J; Hansen, A B; Røhl, H F

    1989-01-01

    A group of 110 consecutive renal stone formers were screened for distal renal tubular acidosis (RTA) using morning fasting urinary pH (mfUpH) levels followed by a short ammonium chloride loading test in patients with levels above 6.0. In 14 patients (12.7%) a renal acidification defect was noted...... RTA in renal stone formers. Regardless of whether the acidification defect is primary or secondary to stone formation, however, all renal stone formers with distal RTA can expect to benefit from prophylactic alkaline therapy and it is recommended that the screening procedure, which is easy to use...

  6. Investigation and deactivation of B Plant HEPA filters

    International Nuclear Information System (INIS)

    Roege, P.E.

    1997-01-01

    This paper describes the integrated approach used to manage environmental, safety, and health considerations related to the B Plant canyon exhaust air filters at the US Department of Energy (DOE) Hanford Site. The narrative illustrates the development and implementation of integrated safety management as applied to a facility and its systems undergoing deactivation. During their lifetime, the high efficiency particulate air (HEPA) filters prevented the release of significant quantities of radioactive materials into the air. As the material in B Plant AVESF accumulated on the filters, it created an unusual situation. Over long periods of time, the radiation dose from the filter loading, combined with aging and chemical exposure actually degrade those filters which were intended to protect against any release to the environment

  7. Recent Advances on Endocrine Disrupting Effects of UV Filters

    Directory of Open Access Journals (Sweden)

    Jiaying Wang

    2016-08-01

    Full Text Available Ultraviolet (UV filters are used widely in cosmetics, plastics, adhesives and other industrial products to protect human skin or products against direct exposure to deleterious UV radiation. With growing usage and mis-disposition of UV filters, they currently represent a new class of contaminants of emerging concern with increasingly reported adverse effects to humans and other organisms. Exposure to UV filters induce various endocrine disrupting effects, as revealed by increasing number of toxicological studies performed in recent years. It is necessary to compile a systematic review on the current research status on endocrine disrupting effects of UV filters toward different organisms. We therefore summarized the recent advances on the evaluation of the potential endocrine disruptors and the mechanism of toxicity for many kinds of UV filters such as benzophenones, camphor derivatives and cinnamate derivatives.

  8. Experimental study of filter cake formation on different filter media

    International Nuclear Information System (INIS)

    Saleem, M.

    2009-01-01

    Removal of particulate matter from gases generated in the process industry is important for product recovery as well as emission control. Dynamics of filtration plant depend on operating conditions. The models, that predict filter plant behaviour, involve empirical resistance parameters which are usually derived from limited experimental data and are characteristics of the filter media and filter cake (dust deposited on filter medium). Filter cake characteristics are affected by the nature of filter media, process parameters and mode of filter regeneration. Removal of dust particles from air is studied in a pilot scale jet pulsed bag filter facility resembling closely to the industrial filters. Limestone dust and ambient air are used in this study with two widely different filter media. All important parameters like pressure drop, gas flow rate, dust settling, are recorded continuously at 1s interval. The data is processed for estimation of the resistance parameters. The pressure drop rise on test filter media is compared. Results reveal that the surface of filter media has an influence on pressure drop rise (concave pressure drop rise). Similar effect is produced by partially jet pulsed filter surface. Filter behaviour is also simulated using estimated parameters and a simplified model and compared with the experimental results. Distribution of cake area load is therefore an important aspect of jet pulse cleaned bag filter modeling. Mean specific cake resistance remains nearly constant on thoroughly jet pulse cleaned membrane coated filter bags. However, the trend can not be confirmed without independent cake height and density measurements. Thus the results reveal the importance of independent measurements of cake resistance. (author)

  9. Generalized Selection Weighted Vector Filters

    Directory of Open Access Journals (Sweden)

    Rastislav Lukac

    2004-09-01

    Full Text Available This paper introduces a class of nonlinear multichannel filters capable of removing impulsive noise in color images. The here-proposed generalized selection weighted vector filter class constitutes a powerful filtering framework for multichannel signal processing. Previously defined multichannel filters such as vector median filter, basic vector directional filter, directional-distance filter, weighted vector median filters, and weighted vector directional filters are treated from a global viewpoint using the proposed framework. Robust order-statistic concepts and increased degree of freedom in filter design make the proposed method attractive for a variety of applications. Introduced multichannel sigmoidal adaptation of the filter parameters and its modifications allow to accommodate the filter parameters to varying signal and noise statistics. Simulation studies reported in this paper indicate that the proposed filter class is computationally attractive, yields excellent performance, and is able to preserve fine details and color information while efficiently suppressing impulsive noise. This paper is an extended version of the paper by Lukac et al. presented at the 2003 IEEE-EURASIP Workshop on Nonlinear Signal and Image Processing (NSIP '03 in Grado, Italy.

  10. A Differential Geometric Approach to Nonlinear Filtering: The Projection Filter

    NARCIS (Netherlands)

    Brigo, D.; Hanzon, B.; LeGland, F.

    1998-01-01

    This paper presents a new and systematic method of approximating exact nonlinear filters with finite dimensional filters, using the differential geometric approach to statistics. The projection filter is defined rigorously in the case of exponential families. A convenient exponential family is

  11. Distally based superficial sural artery flap for soft tissue coverage in the distal 2/3 of leg and foot

    Directory of Open Access Journals (Sweden)

    Kamath B

    2005-01-01

    Full Text Available Background: Skin coverage for defects in the lower 2/3 of leg, ankle region and posterior heel has always been a difficult challenge for reconstructive surgeon. Methods: We describe our experience with the distally based superficial sural artery flap coverage in 48 patients with moderate sized defects in these difficult areas. Results: One out of 48 flaps (in 48 patients was lost totally and 3 suffered marginal necrosis which did not require any secondary procedure. These complications could have been avoided by proper selection of cases and refining technical skills. Conclusion: This simple procedure could be an important and versatile tool for any reconstructive surgeon in providing skin coverage in the distal leg and proximal foot. Preservation of major arteries of the lower limb, minimal donor defect, relatively uninjured donor area in compound fracture or poly trauma involving distal leg are some of the advantages of the flap.

  12. Tomographic anatomy of the vena cava and renal veins: features relevant to vena cava filter placement

    Directory of Open Access Journals (Sweden)

    Thiago Melo do Espírito Santo

    2015-03-01

    Full Text Available BACKGROUND: There is a growing demand for invasive procedures involving the inferior vena cava, in particular for placement of vena cava filters. It is not always easy to identify the more distal renal vein with cavography, for safe release of filters. OBJECTIVES: To determine parameters for the relationships between the renal veins and the infrarenal vena cava and their corresponding vertebral bodies, their relationships with biotype and the occurrence of anatomic variations, the relationships between vertebral bodies and the bifurcation of the common iliac veins and the distance from this bifurcation to the outflow of the more distal renal vein, with reference to placement of vena cava filters. METHODS: A total of 150 abdominal computed tomography scans conducted from October to November 2011 were analyzed and classified according to the biotype exhibited (using Charpy's angle. Scans were performed at MEDIMAGEM and analyzed at the Integrated Vascular Surgery Service, both part of Hospital da Beneficência Portuguesa in São Paulo, Brazil. RESULTS: In 127 of the 150 scans analyzed (84.66%, the more distal renal vein emerged between the first lumbar intervertebral space (L1-L2 and the body of L2, irrespective of patient biotype. Just 23 patients (15.33% exhibited a more distal renal vein with outflow below the body of L2, i.e. in the projection of the space between L2 and L3. CONCLUSIONS: The radiological correlation between the confluence of the more distal renal vein and vertebral bodies exhibits little variation, irrespective of the biotype of the patient.

  13. Analog filters in nanometer CMOS

    CERN Document Server

    Uhrmann, Heimo; Zimmermann, Horst

    2014-01-01

    Starting from the basics of analog filters and the poor transistor characteristics in nanometer CMOS 10 high-performance analog filters developed by the authors in 120 nm and 65 nm CMOS are described extensively. Among them are gm-C filters, current-mode filters, and active filters for system-on-chip realization for Bluetooth, WCDMA, UWB, DVB-H, and LTE applications. For the active filters several operational amplifier designs are described. The book, furthermore, contains a review of the newest state of research on low-voltage low-power analog filters. To cover the topic of the book comprehensively, linearization issues and measurement methods for the characterization of advanced analog filters are introduced in addition. Numerous elaborate illustrations promote an easy comprehension. This book will be of value to engineers and researchers in industry as well as scientists and Ph.D students at universities. The book is also recommendable to graduate students specializing on nanoelectronics, microelectronics ...

  14. Shifted-modified Chebyshev filters

    OpenAIRE

    ŞENGÜL, Metin

    2013-01-01

    This paper introduces a new type of filter approximation method that utilizes shifted-modified Chebyshev filters. Construction of the new filters involves the use of shifted-modified Chebyshev polynomials that are formed using the roots of conventional Chebyshev polynomials. The study also includes 2 tables containing the shifted-modified Chebyshev polynomials and the normalized element values for the low-pass prototype filters up to degree 6. The transducer power gain, group dela...

  15. The magnetic centrifugal mass filter

    International Nuclear Information System (INIS)

    Fetterman, Abraham J.; Fisch, Nathaniel J.

    2011-01-01

    Mass filters using rotating plasmas have been considered for separating nuclear waste and spent nuclear fuel. We propose a new mass filter that utilizes centrifugal and magnetic confinement of ions in a way similar to the asymmetric centrifugal trap. This magnetic centrifugal mass filter is shown to be more proliferation resistant than present technology. This filter is collisional and produces well confined output streams, among other advantages.

  16. The magnetic centrifugal mass filter

    Energy Technology Data Exchange (ETDEWEB)

    Fetterman, Abraham J.; Fisch, Nathaniel J. [Department of Astrophysical Sciences, Princeton University, Princeton, New Jersey 08540 (United States)

    2011-09-15

    Mass filters using rotating plasmas have been considered for separating nuclear waste and spent nuclear fuel. We propose a new mass filter that utilizes centrifugal and magnetic confinement of ions in a way similar to the asymmetric centrifugal trap. This magnetic centrifugal mass filter is shown to be more proliferation resistant than present technology. This filter is collisional and produces well confined output streams, among other advantages.

  17. Limited open reduction is better for simple- distal tibial shaft fractures than minimally invasive plate osteosynthesis.

    Science.gov (United States)

    Li, Q; Zeng, B F; Luo, C F; Song, S; Zhang, C Q; Kong, W Q

    2014-07-24

    The aim of this study was to compare the effects and indications of minimally invasive plate osteosynthesis (MIPO) and limited open reduction (LOR) for managing distal tibial shaft fractures. A total of 79 cases of distal tibial shaft fractures were treated surgically in our trauma center. The 79 fracture cases were classified into type A, B, and C (C1) according to the Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification, with 28, 32, and 19 cases, respectively. Among the 79 fracture cases, 52 were closed fractures and 27 were open fractures (GUSTILO, I-II). After adequate preparation, 48 cases were treated with LOR and 31 cases were treated with MIPO. All cases were followed up for 12 to 18 months, with an average of 16.4 months. During the follow-up period, 76 fracture cases were healed in the first stage, whereas the 3 cases that developed non-union were treated by changing the fixation device and autografting. For types A, B, and some of C simple fractures (C1), LOR accelerated the fracture healing and lowered the non-union rate. One case suffered from regional soft tissue infection, which was controlled by wound dressing and intravenous antibiotics. Another case that developed local skin necrosis underwent local flap transplant. LOR promoted bone healing and lowered the non-union rate of several simple-distal tibial shaft fractures. Thereafter, the incidence of soft tissue complication was not significantly increased. However, for complex and comminuted fractures, MIPO was the preferred method for correcting bone alignment and protecting soft tissue, leading to functional recovery.

  18. Manufacturing a low-cost ceramic water filter and filter system for the elimination of common pathogenic bacteria

    Science.gov (United States)

    Simonis, J. J.; Basson, A. K.

    Africa is one of the most water-scarce continents in the world but it is the lack of potable water which results in diarrhoea being the leading cause of death amongst children under the age of five in Africa (696 million children under 5 years old in Africa contract diarrhoea resulting in 2000 deaths per day: WHO and UNICEF, 2009). Most potable water treatment methods use bulk water treatment not suitable or available to the majority of rural poor in Sub-Saharan Africa. One simple but effective way of making sure that water is of good quality is by purifying it by means of a household ceramic water filter. The making and supply of water filters suitable for the removal of suspended solids, pathogenic bacteria and other toxins from drinking water is therefore critical. A micro-porous ceramic water filter with micron-sized pores was developed using the traditional slip casting process. This locally produced filter has the advantage of making use of less raw materials, cost, labour, energy and expertise and being more effective and efficient than other low cost produced filters. The filter is fitted with a silicone tube inserted into a collapsible bag that acts as container and protection for the filter. Enhanced flow is obtained through this filter system. The product was tested using water inoculated with high concentrations of different bacterial cultures as well as with locally polluted stream water. The filter is highly effective (log10 > 4 with 99.99% reduction efficiency) in providing protection from bacteria and suspended solids found in natural water. With correct cleaning and basic maintenance this filter technology can effectively provide drinking water to rural families affected by polluted surface water sources. This is an African solution for the more than 340 million people in Africa without access to clean drinking water (WHO and UNICEF, 2008).

  19. Multilevel particle filter

    KAUST Repository

    Law, Kody

    2016-01-06

    This talk will pertain to the filtering of partially observed diffusions, with discrete-time observations. It is assumed that only biased approximations of the diffusion can be obtained, for choice of an accuracy parameter indexed by l. A multilevel estimator is proposed, consisting of a telescopic sum of increment estimators associated to the successive levels. The work associated to O( 2) mean-square error between the multilevel estimator and average with respect to the filtering distribution is shown to scale optimally, for example as O( 2) for optimal rates of convergence of the underlying diffusion approximation. The method is illustrated on some toy examples as well as estimation of interest rate based on real S&P 500 stock price data.

  20. Filtered cathodic arc source

    International Nuclear Information System (INIS)

    Falabella, S.; Sanders, D.M.

    1994-01-01

    A continuous, cathodic arc ion source coupled to a macro-particle filter capable of separation or elimination of macro-particles from the ion flux produced by cathodic arc discharge is described. The ion source employs an axial magnetic field on a cathode (target) having tapered sides to confine the arc, thereby providing high target material utilization. A bent magnetic field is used to guide the metal ions from the target to the part to be coated. The macro-particle filter consists of two straight solenoids, end to end, but placed at 45 degree to one another, which prevents line-of-sight from the arc spot on the target to the parts to be coated, yet provides a path for ions and electrons to flow, and includes a series of baffles for trapping the macro-particles. 3 figures

  1. The Rao-Blackwellized Particle Filter: A Filter Bank Implementation

    Directory of Open Access Journals (Sweden)

    Karlsson Rickard

    2010-01-01

    Full Text Available For computational efficiency, it is important to utilize model structure in particle filtering. One of the most important cases occurs when there exists a linear Gaussian substructure, which can be efficiently handled by Kalman filters. This is the standard formulation of the Rao-Blackwellized particle filter (RBPF. This contribution suggests an alternative formulation of this well-known result that facilitates reuse of standard filtering components and which is also suitable for object-oriented programming. Our RBPF formulation can be seen as a Kalman filter bank with stochastic branching and pruning.

  2. Genetics Home Reference: CAV3-related distal myopathy

    Science.gov (United States)

    ... gene causes a peculiar form of distal myopathy. Neurology. 2002 Jan 22;58(2):323-5. Erratum in: Neurology 2002 Mar 12;58(5):839. Itoyoma Y [ ... 3 cause four distinct autosomal dominant muscle diseases. Neurology. 2004 Feb 24;62(4):538-43. Review. ...

  3. Urethral advancement procedure in the treatment of primary distal ...

    African Journals Online (AJOL)

    advancement in the repair of primary distal penile hypospadias with regard to feasibility, complication rates .... stones and growth, and any associated congenital anomaly. Meticulous local examination was performed ... with a tourniquet placed on the root of the penis. A submeatal crescent-like incision was performed a few.

  4. Neglected distal humeral epiphyseal injury - Two Case Reports ...

    African Journals Online (AJOL)

    We present two cases of neglected distal humeral epiphyseal injury in children that resulted in cubitus varus deformity in one case. Full range of movements was achieved in both cases after proper management. Keywords: Neglected epiphyseal injury; Cubitus varus; Diagnosis; Treatment Internet Journal of Medical Update ...

  5. Evaluation of Various Filling Techniques in Distal Canals of ...

    African Journals Online (AJOL)

    2017-03-06

    Mar 6, 2017 ... How to cite this article: Dumani A, Yilmaz S, Yoldas O, Kuden C. Evaluation ... Niger J. Clin Pract 2017;20:307-12. This is an open access article distributed ... in oval-shaped distal canals of mandibular molars was inadequate.

  6. Social Support Contributes to Outcomes following Distal Radius Fractures

    Directory of Open Access Journals (Sweden)

    Caitlin J. Symonette

    2013-01-01

    Full Text Available Background. Distal radius fractures are the most common fracture of the upper extremity and cause variable disability. This study examined the role of social support in patient-reported pain and disability at one year following distal radius fracture. Methods. The Medical Outcomes Study Social Support Survey was administered to a prospective cohort of 291 subjects with distal radius fractures at their baseline visit. Pearson correlations and stepwise linear regression models (F-to-remove 0.10 were used to identify whether social support contributes to wrist fracture outcomes. The primary outcome of pain and disability at one year was measured using the Patient Rated Wrist Evaluation. Results. Most injuries were low energy (67.5% and were treated nonoperatively (71.9%. Pearson correlation analysis revealed that higher reported social support correlated with improved Patient Rated Wrist Evaluation scores at 1 year, r(n=181=-0.22, P<0.05. Of the subscales within the Social Support Survey, emotional/informational support explained a significant proportion of the variance in 1-year Patient Rated Wrist Evaluation scores, R2=4.7%, F (1, 181 = 9.98, P<0.05. Conclusion. Lower emotional/informational social support at the time of distal radius fracture contributes a small but significant percentage to patient-reported pain and disability outcomes.

  7. Simultaneous bilateral distal biceps tendon repair: case report

    Directory of Open Access Journals (Sweden)

    Thiago Medeiros Storti

    Full Text Available ABSTRACT Simultaneous bilateral rupture of the distal biceps tendon is a rare clinical entity, seldom reported in the literature and with unclear therapeutic setting. The authors report the case of a 39-year-old white man who suffered a simultaneous bilateral rupture while working out. When weightlifting with elbows at 90° of flexion, he suddenly felt pain on the anterior aspect of the arms, coming for evaluation after two days. He presented bulging contour of the biceps muscle belly and ecchymosis in the antecubital fossa, extending distally to the medial aspect of the forearm, as well as a marked decrease of supination strength and pain in active elbow flexion. MRI confirmed the rupture with retraction of the distal biceps bilaterally. The authors opted for performing the tendon repairs simultaneously through the double incision technique and fixation to the bicipital tuberosity with anchors. The patient progressed quite well, with full return to labor and sports activities, being satisfied with the result after two years of surgery. In the literature search, few reports of simultaneous bilateral rupture of the distal biceps were retrieved, with only one treated in the acute phase of injury. Therefore, the authors consider this procedure to be a good option to solve this complex condition.

  8. Simultaneous bilateral distal biceps tendon repair: case report.

    Science.gov (United States)

    Storti, Thiago Medeiros; Paniago, Alexandre Firmino; Faria, Rafael Salomon Silva

    2017-01-01

    Simultaneous bilateral rupture of the distal biceps tendon is a rare clinical entity, seldom reported in the literature and with unclear therapeutic setting. The authors report the case of a 39-year-old white man who suffered a simultaneous bilateral rupture while working out. When weightlifting with elbows at 90° of flexion, he suddenly felt pain on the anterior aspect of the arms, coming for evaluation after two days. He presented bulging contour of the biceps muscle belly and ecchymosis in the antecubital fossa, extending distally to the medial aspect of the forearm, as well as a marked decrease of supination strength and pain in active elbow flexion. MRI confirmed the rupture with retraction of the distal biceps bilaterally. The authors opted for performing the tendon repairs simultaneously through the double incision technique and fixation to the bicipital tuberosity with anchors. The patient progressed quite well, with full return to labor and sports activities, being satisfied with the result after two years of surgery. In the literature search, few reports of simultaneous bilateral rupture of the distal biceps were retrieved, with only one treated in the acute phase of injury. Therefore, the authors consider this procedure to be a good option to solve this complex condition.

  9. Evaluation of various filling techniques in distal canals of mandibular ...

    African Journals Online (AJOL)

    Evaluation of various filling techniques in distal canals of mandibular molars instrumented with different single-file nickel-titanium systems. ... Comparisons between groups were applied using Student's t-test or one-way ANOVA for normally distributed data. The Mann-Whitney U-test or Kruskal-Wallis test was used when ...

  10. A unique physeal injury of the distal phalanx.

    Science.gov (United States)

    Berber, Onur; Singh, Bijayendra

    2015-01-01

    An unusual Salter-Harris Type 1 fracture variant of the distal phalanx of the index finger is described. The epiphysis was dislocated, sitting dorsally over the middle phalanx head with the articular surface facing dorsal. Reduction could only be achieved through an open procedure. The reduction was stable without supplemental fixation.

  11. Unusual migration of ventriculo peritoneal distal catheter into vagina

    Directory of Open Access Journals (Sweden)

    Sghavamedin Tavallaee

    2015-04-01

    Full Text Available VP shunt is one of the most popular methods for ICP reduction and treatment of hydrocephalus. Various complications of this method are not uncommon such as shunt malfunction, infection and unusual migration of distal catheter. I present a case of migration of the peritoneal catheter out of the vagina.

  12. Laparoscopic versus open distal pancreatectomy for pancreatic cancer

    NARCIS (Netherlands)

    Riviere, D.M.; Gurusamy, K.S.; Kooby, D.A.; Vollmer, C.M.; Besselink, M.G.; Davidson, B.R.; Laarhoven, C.J.H.M. van

    2016-01-01

    BACKGROUND: Surgical resection is currently the only treatment with the potential for long-term survival and cure of pancreatic cancer. Surgical resection is provided as distal pancreatectomy for cancers of the body and tail of the pancreas. It can be performed by laparoscopic or open surgery. In

  13. Laparoscopic versus open distal pancreatectomy for pancreatic cancer

    NARCIS (Netherlands)

    Riviere, Deniece; Gurusamy, Kurinchi Selvan; Kooby, David A.; Vollmer, Charles M.; Besselink, Marc G. H.; Davidson, Brian R.; van Laarhoven, Cornelis J. H. M.

    2016-01-01

    Surgical resection is currently the only treatment with the potential for long-term survival and cure of pancreatic cancer. Surgical resection is provided as distal pancreatectomy for cancers of the body and tail of the pancreas. It can be performed by laparoscopic or open surgery. In operations on

  14. Autosomal dominant distal myopathy: Linkage to chromosome 14

    Energy Technology Data Exchange (ETDEWEB)

    Laing, N.G.; Laing, B.A.; Wilton, S.D.; Dorosz, S.; Mastaglia, F.L.; Kakulas, B.A. [Australian Neuromuscular Research Institute, Perth (Australia); Robbins, P.; Meredith, C.; Honeyman, K.; Kozman, H.

    1995-02-01

    We have studied a family segregating a form of autosomal dominant distal myopathy (MIM 160500) and containing nine living affected individuals. The myopathy in this family is closest in clinical phenotype to that first described by Gowers in 1902. A search for linkage was conducted using microsatellite, VNTR, and RFLP markers. In total, 92 markers on all 22 autosomes were run. Positive linkage was obtained with 14 of 15 markers tested on chromosome 14, with little indication of linkage elsewhere in the genome. Maximum two-point LOD scores of 2.60 at recombination fraction .00 were obtained for the markers MYH7 and D14S64 - the family structure precludes a two-point LOD score {ge} 3. Recombinations with D14S72 and D14S49 indicate that this distal myopathy locus, MPD1, should lie between these markers. A multipoint analysis assuming 100% penetrance and using the markers D14S72, D14S50, MYH7, D14S64, D14S54, and D14S49 gave a LOD score of exactly 3 at MYH7. Analysis at a penetrance of 80% gave a LOD score of 2.8 at this marker. This probable localization of a gene for distal myopathy, MPD1, on chromosome 14 should allow other investigators studying distal myopathy families to test this region for linkage in other types of the disease, to confirm linkage or to demonstrate the likely genetic heterogeneity. 24 refs., 3 figs., 1 tab.

  15. Detection of Lateglacial distal tephra layers in the Netherlands

    NARCIS (Netherlands)

    Davies, S.M.; Hoek, W.Z.; Bohncke, S.J.P.; Lowe, J.; Pyne O'Donnle, S.; Turney, C.S.M.

    2005-01-01

    Three distal tephra layers or cryptotephras have been detected within a sedimentary sequence from the Netherlands that spans the last glacial-interglacial transition. Geochemical analyses identify one as the Vedde Ash, which represents the southernmost discovery of this mid-Younger Dryas tephra so

  16. Outcome of management of distal radius fractures in ...

    African Journals Online (AJOL)

    Background and Purpose: Distal radial fractures are common fractures of postmenopausal age group patients. They are often called fractures of osteoporosis. These fractures are considered to be one of the commonest minor injuries to cause major morbidity in the community. A lot of patient who need surgery, fail to afford ...

  17. Snodgrass repair for distal hypospadias: a review of 75 cases

    African Journals Online (AJOL)

    urologists for distal hypospadias correction. We review our cases to find out whether there was any difference in the rate of urethrocutaneous fistula after the use of single- versus double-layer tubularization, the use of thick versus thin dorsal prepuce subcutaneous flap (DPF), the use of. DPF versus the ventral dartos flap for ...

  18. Spontaneous resolution of splenic infarcts after distal splenorenal ...

    African Journals Online (AJOL)

    Background: In cases of portal hypertension with splenic infarcts, splenectomy with proximal splenorenal shunt has been recommended. We are sharing our experience with distal splenorenal shunt in these cases contrary to the popular belief. Materials and Methods: Splenic infarcts were graded as mild, moderate and ...

  19. Class II correction prior to orthodontics with the carriere distalizer.

    Science.gov (United States)

    McFarlane, Bruce

    2013-01-01

    Class II correction is a challenge in orthodontics with many existing devices being complex, too compliance-driven, or too prone to breakage. The Carriere Distalizer allows for straightforward Class II correction prior to orthodontics (fixed or clear aligners) at a time when no other mechanics interfere, and compliance is at its best.

  20. The distal shoe space maintainer chairside fabrication and clinical performance.

    Science.gov (United States)

    Brill, Warren A

    2002-01-01

    The chairside-fabricated distal shoe appliance, with a stainless steel crown as the retainer, is an efficacious and cost-effective appliance for guiding the unerupted permanent first molar into position after premature loss or extraction of the second primary molar. The fabrication technique is illustrated in this case report and data is presented on the success rate of the appliance.

  1. Manipulation Robustness of Collaborative Filtering

    OpenAIRE

    Benjamin Van Roy; Xiang Yan

    2010-01-01

    A collaborative filtering system recommends to users products that similar users like. Collaborative filtering systems influence purchase decisions and hence have become targets of manipulation by unscrupulous vendors. We demonstrate that nearest neighbors algorithms, which are widely used in commercial systems, are highly susceptible to manipulation and introduce new collaborative filtering algorithms that are relatively robust.

  2. Quick-change filter cartridge

    Science.gov (United States)

    Rodgers, John C.; McFarland, Andrew R.; Ortiz, Carlos A.

    1995-01-01

    A quick-change filter cartridge. In sampling systems for measurement of airborne materials, a filter element is introduced into the sampled airstream such that the aerosol constituents are removed and deposited on the filter. Fragile sampling media often require support in order to prevent rupture during sampling, and careful mounting and sealing to prevent misalignment, tearing, or creasing which would allow the sampled air to bypass the filter. Additionally, handling of filter elements may introduce cross-contamination or exposure of operators to toxic materials. Moreover, it is desirable to enable the preloading of filter media into quick-change cartridges in clean laboratory environments, thereby simplifying and expediting the filter-changing process in the field. The quick-change filter cartridge of the present invention permits the application of a variety of filter media in many types of instruments and may also be used in automated systems. The cartridge includes a base through which a vacuum can be applied to draw air through the filter medium which is located on a porous filter support and held there by means of a cap which forms an airtight seal with the base. The base is also adapted for receiving absorbing media so that both particulates and gas-phase samples may be trapped for investigation, the latter downstream of the aerosol filter.

  3. Filter Effectiveness Evaluation

    Science.gov (United States)

    2013-08-01

    synthetic paraffinic kerosene (SPK), as well as Ultra Low Sulfur Diesel (ULSD) treated with mono-olein to simulate the effects of biodiesel . Results...fuel. Sufficient analysis and qualification of filter products is becoming increasingly crucial in ground transportation vehicles to promote the...well as a simulated biodiesel composed of ultra low sulfur diesel (ULSD) and mono-olein. As written in the scope of work, the alternative aviation

  4. A novel patch-field design using an optimized grid filter for passively scattered proton beams

    International Nuclear Information System (INIS)

    Li Yupeng; Zhang Xiaodong; Dong Lei; Mohan, Radhe

    2007-01-01

    For tumors with highly complex shapes, a 'patching' strategy is often used in passively scattered proton therapy to match the sharp distal edge of the spread-out Bragg peak (SOBP) of the patch field to the lateral penumbra of the through field at 50% dose level. The differences in the dose gradients at the distal edge and at the lateral penumbra could cause hot and cold doses at the junction. In this note, we describe an algorithm developed to optimize the range compensator design to yield a more uniform dose distribution at the junction. The algorithm is based on the fact that the distal fall-off of the SOBP can be tailored using a grid filter that is placed perpendicular to the beam's path. The filter is optimized so that the distal fall-off of the patch field complements the lateral penumbra fall-off of the through field. In addition to optimizing the fall-off, the optimization process implicitly accounts for the limitations of conventional compensator design algorithms. This algorithm uses simple ray tracing to determine the compensator shape and ignore scatter. The compensated dose distribution may therefore differ substantially from the intended dose distribution, especially when complex heterogeneities are encountered, such as those in the head and neck. In such a case, an adaptive optimization strategy can be used to optimize the 'grid' filter locally considering the tissue heterogeneities. The grid filter thus obtained is superimposed on the original range compensator so that the composite compensator leads to a more uniform dose distribution at the patch junction. An L-shaped head and neck tumor was used to demonstrate the validity of the proposed algorithm. A robustness analysis with focus on range uncertainty effect is carried out. (note)

  5. Matched-Filter Thermography

    Directory of Open Access Journals (Sweden)

    Nima Tabatabaei

    2018-04-01

    Full Text Available Conventional infrared thermography techniques, including pulsed and lock-in thermography, have shown great potential for non-destructive evaluation of broad spectrum of materials, spanning from metals to polymers to biological tissues. However, performance of these techniques is often limited due to the diffuse nature of thermal wave fields, resulting in an inherent compromise between inspection depth and depth resolution. Recently, matched-filter thermography has been introduced as a means for overcoming this classic limitation to enable depth-resolved subsurface thermal imaging and improving axial/depth resolution. This paper reviews the basic principles and experimental results of matched-filter thermography: first, mathematical and signal processing concepts related to matched-fileting and pulse compression are discussed. Next, theoretical modeling of thermal-wave responses to matched-filter thermography using two categories of pulse compression techniques (linear frequency modulation and binary phase coding are reviewed. Key experimental results from literature demonstrating the maintenance of axial resolution while inspecting deep into opaque and turbid media are also presented and discussed. Finally, the concept of thermal coherence tomography for deconvolution of thermal responses of axially superposed sources and creation of depth-selective images in a diffusion-wave field is reviewed.

  6. Carbon nanotube filters

    Science.gov (United States)

    Srivastava, A.; Srivastava, O. N.; Talapatra, S.; Vajtai, R.; Ajayan, P. M.

    2004-09-01

    Over the past decade of nanotube research, a variety of organized nanotube architectures have been fabricated using chemical vapour deposition. The idea of using nanotube structures in separation technology has been proposed, but building macroscopic structures that have controlled geometric shapes, density and dimensions for specific applications still remains a challenge. Here we report the fabrication of freestanding monolithic uniform macroscopic hollow cylinders having radially aligned carbon nanotube walls, with diameters and lengths up to several centimetres. These cylindrical membranes are used as filters to demonstrate their utility in two important settings: the elimination of multiple components of heavy hydrocarbons from petroleum-a crucial step in post-distillation of crude oil-with a single-step filtering process, and the filtration of bacterial contaminants such as Escherichia coli or the nanometre-sized poliovirus (~25 nm) from water. These macro filters can be cleaned for repeated filtration through ultrasonication and autoclaving. The exceptional thermal and mechanical stability of nanotubes, and the high surface area, ease and cost-effective fabrication of the nanotube membranes may allow them to compete with ceramic- and polymer-based separation membranes used commercially.

  7. Controlling flow conditions of test filters in iodine filters

    International Nuclear Information System (INIS)

    Holmberg, R.; Laine, J.

    1979-03-01

    Several different iodine filter and test filter designs and experience gained from their operation are presented. For the flow experiments, an iodine filter system equipped with flow regulating and measuring devices was built. In the experiments the influence of the packing method of the iodine sorption material and the influence of the flow regulating and measuring divices upon the flow conditions in the test filters was studied. On the basis of the experiments it has been shown that the flows through the test filters always can be adjusted to a correct value if there only is a high enough pressure difference available across the test filter ducting. As a result of the research, several different methods are presented with which the flows through the test filters in both operating and future iodine sorption system can easily be measured and adjusted to their correct values. (author)

  8. Laparoscopic radical nephroureterectomy: dilemma of the distal ureter.

    Science.gov (United States)

    Steinberg, Jordan R; Matin, Surena F

    2004-03-01

    Laparoscopic nephroureterectomy has recently emerged as a safe, minimally invasive approach to upper tract urothelial cancers. The most controversial and challenging feature of laparoscopic nephroureterectomy is the management of the distal ureter. We review the most common methods of managing the distal ureter, with emphasis on contemporary oncologic outcomes, indications, advantages, and disadvantages. There are currently in excess of five different approaches to the lower ureter. These techniques often combine features of endoscopic, laparoscopic, or open management. They include open excision, a transvesical laparoscopic detachment and ligation technique, laparoscopic stapling of the distal ureter and bladder cuff, the "pluck" technique, and ureteral intussusception. Each technique has distinct advantages and disadvantages, differing not only in technical approach, but oncological principles as well. While the existing published data do not overwhelmingly support one approach over the others, the open approach remains one of the most reliable and oncologically sound procedures. The principles of surgical oncology dictate that a complete, en-bloc resection, with avoidance of tumor seeding, remains the preferred treatment of all urothelial cancers. The classical open technique of securing the distal ureter and bladder cuff achieves this principle and has withstood the test of time. Transvesical laparoscopic detachment and ligation is an oncologically valid approach in patients without bladder tumors, but is limited by technical considerations. The laparoscopic stapling technique maintains a closed system but risks leaving behind ureteral and bladder cuff segments. Both transurethral resection of the ureteral orifice (pluck) and intussusception techniques should be approached with caution, as the potential for tumor seeding exists. Additional long-term comparative outcomes are needed to solve the dilemma of the distal ureter.

  9. Distal pancreatectomy and splenectomy: a robotic or LESS approach.

    Science.gov (United States)

    Ryan, Carrie E; Ross, Sharona B; Sukharamwala, Prashant B; Sadowitz, Benjamin D; Wood, Thomas W; Rosemurgy, Alexander S

    2015-01-01

    The role and application of robotic surgery are debated, particularly given the expansion of laparoscopy, especially laparoendoscopic single-site (LESS) surgery. This cohort study was undertaken to delineate differences in outcomes between LESS and robotic distal pancreatectomy and splenectomy. With Institutional Review Board approval, patients undergoing LESS or robotic distal pancreatectomy and splenectomy from September 1, 2012, through December 31, 2014, were prospectively observed, and data were collected. The results are expressed as the median, with the mean ± SD. Thirty-four patients underwent a minimally invasive distal pancreatectomy and splenectomy: 18 with robotic and 16 with LESS surgery. The patients were similar in sex, age, and body mass index. Conversions to open surgery and estimated blood loss were similar. There were two intraoperative complications in the group that underwent the robotic approach. Time spent in the operating room was significantly longer with the robot (297 vs 254 minutes, P = .03), although operative duration (i.e., incision to closure) was not longer (225 vs 190 minutes; P = .15). Of the operations studied, 79% were undertaken for neoplastic processes. Tumor size was 3.5 cm for both approaches; R0 resections were achieved in all patients. Length of stay was similar in the two study groups (5 vs 4 days). There was one 30-day readmission after robotic surgery. Patient outcomes are similar with LESS or robotic distal pancreatectomy and splenectomy. Robotic operations require more time in the operating room. Both are safe and efficacious minimally invasive operations that follow similar oncologic principles for similar tumors, and both should be in the surgeon's armamentarium for distal pancreatectomy and splenectomy.

  10. Distal Oblique Bundle Reinforcement for Treatment of DRUJ Instability.

    Science.gov (United States)

    Brink, Peter R G; Hannemann, Pascal F W

    2015-08-01

    Background Chronic, dynamic bidirectional instability in the distal radioulnar joint (DRUJ) is diagnosed clinically, based on the patient's complaints and the finding of abnormal laxity in the vicinity of the distal ulna. In cases where malunion is ruled out or treated and there are no signs of osteoarthritis, stabilization of the DRUJ may offer relief. To this end, several different techniques have been investigated over the past 90 years. Materials and Methods In this article we outline the procedure for a new technique using a tendon graft to reinforce the distal edge of the interosseous membrane. Description of Technique A percutaneous technique is used to harvest the palmaris longus tendon and to create a tunnel, just proximal to the sigmoid notch, through the ulna and radius in an oblique direction. By overdrilling the radial cortex, the knotted tendon can be pulled through the radius and ulna and the knot blocked at the second radial cortex, creating a strong connection between the radius and ulna at the site of the distal oblique bundle (DOB). The tendon is fixed in the ulna with a small interference screw in full supination, preventing subluxation of the ulna out of the sigmoid notch during rotation. Results Fourteen patients were treated with this novel technique between 2011 and October 2013. The QuickDASH score at 25 months postoperatively (range 16-38 months) showed an improvement of 32 points. Similarly, an improvement of 33 points (67-34 months) was found on the PRWHE. Only one recurrence of chronic, dynamic bidirectional instability in the DRUJ was observed. Conclusion This simple percutaneous tenodesis technique between radius and ulna at the position of the distal edge of the interosseous membrane shows promise in terms of both restoring stability and relieving complaints related to chronic subluxation in the DRUJ.

  11. The history of ceramic filters.

    Science.gov (United States)

    Fujishima, S

    2000-01-01

    The history of ceramic filters is surveyed. Included is the history of piezoelectric ceramics. Ceramic filters were developed using technology similar to that of quartz crystal and electro-mechanical filters. However, the key to this development involved the theoretical analysis of vibration modes and material improvements of piezoelectric ceramics. The primary application of ceramic filters has been for consumer-market use. Accordingly, a major emphasis has involved mass production technology, leading to low-priced devices. A typical ceramic filter includes monolithic resonators and capacitors packaged in unique configurations.

  12. Minimally invasive plating osteosynthesis for mid-distal third humeral shaft fractures.

    Science.gov (United States)

    Lian, Kejian; Wang, Lei; Lin, Dasheng; Chen, Zhiwen

    2013-08-01

    Mid-distal third humeral shaft fractures can be effectively treated with minimally invasive plating osteosynthesis and intramedullary nailing (IMN). However, these 2 treatments have not been adequately compared. Forty-seven patients (47 fractures) with mid-distal third humeral shaft fractures were randomly allocated to undergo either minimally invasive plating osteosynthesis (n=24) or IMN (n=23). The 2 groups were similar in terms of fracture patterns, fracture location, age, and associated injuries. Intraoperative measurements included blood loss and operative time. Clinical outcome measurements included fracture healing, radial nerve recovery, and elbow and shoulder discomfort. Radiographic measurements included fracture alignment, time to healing, delayed union, and nonunion. Functional outcome was satisfactory in both groups. Mean American Shoulder and Elbow Surgeons score and Mayo score were both better for the minimally invasive plating osteosynthesis group than for the IMN group (98.2 vs 97.6, respectively, and 93.5 vs 94.1, respectively; Pshaft fractures. Minimally invasive plating osteosynthesis is more suitable for complex fractures, especially for radial protection and motion recovery of adjacent joints, compared with IMN for simple fractures. Copyright 2013, SLACK Incorporated.

  13. Mechanical design and qualification of IR filter mounts and filter wheel of INSAT-3D sounder for low temperature

    Science.gov (United States)

    Vora, A. P.; Rami, J. B.; Hait, A. K.; Dewan, C. P.; Subrahmanyam, D.; Kirankumar, A. S.

    2017-11-01

    Next generation Indian Meteorological Satellite will carry Sounder instrument having subsystem of filter wheel measuring Ø260mm and carrying 18 filters arranged in three concentric rings. These filters made from Germanium, are used to separate spectral channels in IR band. Filter wheel is required to be cooled to 214K and rotated at 600 rpm. This Paper discusses the challenges faced in mechanical design of the filter wheel, mainly filter mount design to protect brittle germanium filters from failure under stresses due to very low temperature, compactness of the wheel and casings for improved thermal efficiency, survival under vibration loads and material selection to keep it lighter in weight. Properties of Titanium, Kovar, Invar and Aluminium materials are considered for design. The mount has been designed to accommodate both thermal and dynamic loadings without introducing significant aberrations into the optics or incurring permanent alignment shifts. Detailed finite element analysis of mounts was carried out for stress verification. Results of the qualification tests are discussed for given temperature range of 100K and vibration loads of 12g in Sine and 11.8grms in Random at mount level. Results of the filter wheel qualification as mounted in Electro Optics Module (EOM) are also presented.

  14. Kaon Filtering For CLAS Data

    International Nuclear Information System (INIS)

    McNabb, J.

    2001-01-01

    The analysis of data from CLAS is a multi-step process. After the detectors for a given running period have been calibrated, the data is processed in the so called pass-1 cooking. During the pass-1 cooking each event is reconstructed by the program a1c which finds particle tracks and computes momenta from the raw data. The results are then passed on to several data monitoring and filtering utilities. In CLAS software, a filter is a parameterless function which returns an integer indicating whether an event should be kept by that filter or not. There is a main filter program called g1-filter which controls several specific filters and outputs several files, one for each filter. These files may then be analyzed separately, allowing individuals interested in one reaction channel to work from smaller files than using the whole data set would require. There are several constraints on what the filter functions should do. Obviously, the filtered files should be as small as possible, however the filter should also not reject any events that might be used in the later analysis for which the filter was intended

  15. OPTIMIZATION OF ADVANCED FILTER SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    R.A. Newby; G.J. Bruck; M.A. Alvin; T.E. Lippert

    1998-04-30

    Reliable, maintainable and cost effective hot gas particulate filter technology is critical to the successful commercialization of advanced, coal-fired power generation technologies, such as IGCC and PFBC. In pilot plant testing, the operating reliability of hot gas particulate filters have been periodically compromised by process issues, such as process upsets and difficult ash cake behavior (ash bridging and sintering), and by design issues, such as cantilevered filter elements damaged by ash bridging, or excessively close packing of filtering surfaces resulting in unacceptable pressure drop or filtering surface plugging. This test experience has focused the issues and has helped to define advanced hot gas filter design concepts that offer higher reliability. Westinghouse has identified two advanced ceramic barrier filter concepts that are configured to minimize the possibility of ash bridge formation and to be robust against ash bridges should they occur. The ''inverted candle filter system'' uses arrays of thin-walled, ceramic candle-type filter elements with inside-surface filtering, and contains the filter elements in metal enclosures for complete separation from ash bridges. The ''sheet filter system'' uses ceramic, flat plate filter elements supported from vertical pipe-header arrays that provide geometry that avoids the buildup of ash bridges and allows free fall of the back-pulse released filter cake. The Optimization of Advanced Filter Systems program is being conducted to evaluate these two advanced designs and to ultimately demonstrate one of the concepts in pilot scale. In the Base Contract program, the subject of this report, Westinghouse has developed conceptual designs of the two advanced ceramic barrier filter systems to assess their performance, availability and cost potential, and to identify technical issues that may hinder the commercialization of the technologies. A plan for the Option I, bench

  16. Advances in Collaborative Filtering

    Science.gov (United States)

    Koren, Yehuda; Bell, Robert

    The collaborative filtering (CF) approach to recommenders has recently enjoyed much interest and progress. The fact that it played a central role within the recently completed Netflix competition has contributed to its popularity. This chapter surveys the recent progress in the field. Matrix factorization techniques, which became a first choice for implementing CF, are described together with recent innovations. We also describe several extensions that bring competitive accuracy into neighborhood methods, which used to dominate the field. The chapter demonstrates how to utilize temporal models and implicit feedback to extend models accuracy. In passing, we include detailed descriptions of some the central methods developed for tackling the challenge of the Netflix Prize competition.

  17. Adaptive projective filters

    International Nuclear Information System (INIS)

    Dikusar, N.D.

    1993-01-01

    The new approach to solving of the finding problem is proposed. The method is based on Discrete Projective Transformations (DPT), the List Square Fitting (LSF) and uses the information feedback in tracing for linear or quadratic track segments (TS). The fast and stable with respect to measurement errors and background points recurrent algorithm is suggested. The algorithm realizes the family of digital adaptive projective filters (APF) with known nonlinear weight functions-projective invariants. APF can be used in adequate control systems for collection, processing and compression of data, including tracking problems for the wide class of detectors. 10 refs.; 9 figs

  18. Multilevel ensemble Kalman filtering

    KAUST Repository

    Hoel, Hakon

    2016-06-14

    This work embeds a multilevel Monte Carlo sampling strategy into the Monte Carlo step of the ensemble Kalman filter (EnKF) in the setting of finite dimensional signal evolution and noisy discrete-time observations. The signal dynamics is assumed to be governed by a stochastic differential equation (SDE), and a hierarchy of time grids is introduced for multilevel numerical integration of that SDE. The resulting multilevel EnKF is proved to asymptotically outperform EnKF in terms of computational cost versus approximation accuracy. The theoretical results are illustrated numerically.

  19. Interdigital filter design

    CSIR Research Space (South Africa)

    Du Plessis, WP

    2009-10-01

    Full Text Available to the general inverter-coupled resonator bandpass filter structure in Figure 2 [6] by using the inverter shown in Figure 3. The admittance of the inverter in Figure 3 is 4 J= Y mn sin(βl) (1) where β is the propagation factor and l is the length... of the resonators (a quarter wavelength in this case). While the series quarter-wave line alone can approximate an inverter, the structure shown in Figure 3 is more accurate over wide bandwidths. At this point the circuits in Figures 1 and 2 still differ because...

  20. Multilevel ensemble Kalman filtering

    KAUST Repository

    Hoel, Hakon; Law, Kody J. H.; Tempone, Raul

    2016-01-01

    This work embeds a multilevel Monte Carlo sampling strategy into the Monte Carlo step of the ensemble Kalman filter (EnKF) in the setting of finite dimensional signal evolution and noisy discrete-time observations. The signal dynamics is assumed to be governed by a stochastic differential equation (SDE), and a hierarchy of time grids is introduced for multilevel numerical integration of that SDE. The resulting multilevel EnKF is proved to asymptotically outperform EnKF in terms of computational cost versus approximation accuracy. The theoretical results are illustrated numerically.

  1. Charcoal filter testing

    Energy Technology Data Exchange (ETDEWEB)

    Lyons, J. [Nuclear Regulatory Commission, Washington, DC (United States)

    1997-08-01

    In this very brief, informal presentation, a representative of the US Nuclear Regulatory Commission outlines some problems with charcoal filter testing procedures and actions being taken to correct the problems. Two primary concerns are addressed: (1) the process to find the test method is confusing, and (2) the requirements of the reference test procedures result in condensation on the charcoal and causes the test to fail. To address these problems, emergency technical specifications were processed for three nuclear plants. A generic or an administrative letter is proposed as a more permanent solution. 1 fig.

  2. Multicentre prospective evaluation of implant-assisted mandibular bilateral distal extension removable partial dentures: patient satisfaction

    NARCIS (Netherlands)

    Wismeijer, D.; Tawse-Smith, A.; Payne, A.G.T.

    2013-01-01

    Objective To compare the levels of patient satisfaction with either conventional mandibular bilateral distal extension partial dentures or those assisted by bilateral distal implants. Materials and methods Forty-eight participants who were dissatisfied with their existing conventional mandibular

  3. Minimally invasive versus open distal pancreatectomy (LEOPARD) : Study protocol for a randomized controlled trial

    NARCIS (Netherlands)

    de Rooij, Thijs; van Hilst, Jony; Vogel, Jantien A.; van Santvoort, Hjalmar C.; de Boer, Marieke T.; Boerma, Djamila; van den Boezem, Peter B.; Bonsing, Bert A.; Bosscha, Koop; Coene, Peter-Paul; Daams, Freek; van Dam, Ronald M.; Dijkgraaf, Marcel G.; van Eijck, Casper H.; Festen, Sebastiaan; Gerhards, Michael F.; Koerkamp, Bas Groot; Hagendoorn, Jeroen; van der Harst, Erwin; de Hingh, Ignace H.; Dejong, Cees H.; Kazemier, Geert; Klaase, Joost; de Kleine, Ruben H.; van Laarhoven, Cornelis J.; Lips, Daan J.; Luyer, Misha D.; Molenaar, I. Quintus; Nieuwenhuijs, Vincent B.; Patijn, Gijs A.; Roos, Daphne; Scheepers, Joris J.; van der Schelling, George P.; Steenvoorde, Pascal; Swijnenburg, Rutger-Jan; Wijsman, Jan H.; Abu Hilal, Moh'd; Busch, Olivier R.; Besselink, Marc G.

    2017-01-01

    Background: Observational cohort studies have suggested that minimally invasive distal pancreatectomy (MIDP) is associated with better short-term outcomes compared with open distal pancreatectomy (ODP), such as less intraoperative blood loss, lower morbidity, shorter length of hospital stay, and

  4. Multicenter comparative study of laparoscopic and open distal pancreatectomy using propensity score-matching.

    Science.gov (United States)

    Nakamura, Masafumi; Wakabayashi, Go; Miyasaka, Yoshihiro; Tanaka, Masao; Morikawa, Takanori; Unno, Michiaki; Tajima, Hiroshi; Kumamoto, Yusuke; Satoi, Sohei; Kwon, Masanori; Toyama, Hirochika; Ku, Yonson; Yoshitomi, Hideyuki; Nara, Satoshi; Shimada, Kazuaki; Yokoyama, Takahide; Miyagawa, Shinichi; Toyama, Yoichi; Yanaga, Katsuhiko; Fujii, Tsutomu; Kodera, Yasuhiro; Tomiyama, Yasuyuki; Miyata, Hiroaki; Takahara, Takeshi; Beppu, Toru; Yamaue, Hiroki; Miyazaki, Masaru; Takada, Tadahiro

    2015-10-01

    Laparoscopic distal pancreatectomy has been shown to be associated with favorable postoperative outcomes using meta-analysis. However, there have been no randomized controlled studies yet. This study aimed to compare laparoscopic and open distal pancreatectomy using propensity score-matching. We retrospectively collected perioperative data of 2,266 patients who underwent distal pancreatectomy in 69 institutes from 2006-2013 in Japan. Among them, 2,010 patients were enrolled in this study and divided into two groups, laparoscopic distal pancreatectomy and open distal pancreatectomy. Perioperative outcomes were compared between the groups using unmatched and propensity matched analysis. After propensity score-matching, laparoscopic distal pancreatectomy was associated with favorable perioperative outcomes compared with open distal pancreatectomy, including higher rate of preservation of spleen and splenic vessels (P pancreatectomy was associated with more favorable perioperative outcomes than open distal pancreatectomy. © 2015 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  5. Digital Filters for Low Frequency Equalization

    DEFF Research Database (Denmark)

    Tyril, Marni; Abildgaard, J.; Rubak, Per

    2001-01-01

    Digital filters with high resolution in the low-frequency range are studied. Specifically, for a given computational power, traditional IIR filters are compared with warped FIR filters, warped IIR filters, and modified warped FIR filters termed warped individual z FIR filters (WizFIR). The results...

  6. High flow ceramic pot filters.

    Science.gov (United States)

    van Halem, D; van der Laan, H; Soppe, A I A; Heijman, S G J

    2017-11-01

    Ceramic pot filters are considered safe, robust and appropriate technologies, but there is a general consensus that water revenues are limited due to clogging of the ceramic element. The objective of this study was to investigate the potential of high flow ceramic pot filters to produce more water without sacrificing their microbial removal efficacy. High flow pot filters, produced by increasing the rice husk content, had a higher initial flow rate (6-19 L h -1 ), but initial LRVs for E. coli of high flow filters was slightly lower than for regular ceramic pot filters. This disadvantage was, however, only temporarily as the clogging in high flow filters had a positive effect on the LRV for E. coli (from below 1 to 2-3 after clogging). Therefore, it can be carefully concluded that regular ceramic pot filters perform better initially, but after clogging, the high flow filters have a higher flow rate as well as a higher LRV for E. coli. To improve the initial performance of new high flow filters, it is recommended to further utilize residence time of the water in the receptacle, since additional E. coli inactivation was observed during overnight storage. Although a relationship was observed between flow rate and LRV of MS2 bacteriophages, both regular and high flow filters were unable to reach over 2 LRV. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Single absorbable polydioxanone pin fixation for distal chevron bunion osteotomies.

    Science.gov (United States)

    Deorio, J K; Ware, A W

    2001-10-01

    The distal chevron osteotomy is a well-established technique for correction of symptomatic mild to moderate metatarsus primus varus with hallux valgus deformity. Fixation of the osteotomy ranges from none to bone pegs, Kirschner wires, screws, or absorbable pins. We evaluated one surgeon's (J.K.D.) results of distal chevron osteotomy fixation with a single, nonpredrilled, 1.3-mm poly-p-dioxanone pin and analyzed any differences in patients with unilateral or bilateral symptomatic metatarsus primus varus with hallux valgus deformities. All osteotomies healed without evidence of infection, osteolysis, nonunion, or necrosis. Equal correction was achieved in unilateral and bilateral procedures. The technique is quick and easy, and adequate fixation is achieved.

  8. Osteomyelitis Caused by Candida glabrata in the Distal Phalanx

    Directory of Open Access Journals (Sweden)

    Shunichi Toki

    2014-01-01

    Full Text Available Osteomyelitis caused by Candida glabrata is rare and its optimal treatment is unknown. Here we report a case of osteomyelitis caused by C. glabrata in the distal phalanx in a 54-year-old woman. Despite partial resection of the nail and administering a 1-month course of antibiotics for paronychia, the local swelling remained and an osteolytic lesion was found. C. glabrata osteomyelitis of the distal phalanx was later diagnosed after curettage. Thereafter, the patient was treated with antifungal agents for 3 months. The infection eventually resolved, and radiological healing of the osteolytic lesion was achieved. Antifungal susceptibility testing should be performed in the case of osteomyelitis caused by nonalbicans Candida species, due to their resistance to fluconazole.

  9. Retrograde nailing for distal femur fractures in the elderly

    Directory of Open Access Journals (Sweden)

    Giddie Jasdeep

    2015-01-01

    Full Text Available Introduction: We report the results of treating a series of 56 fractures in 54 elderly patients with a distal femur fracture with a retrograde femoral nail. Methods: Fifty-four of the nails were inserted percutaneously with a closed reduction. After surgery all patients were allowed to weight bear as tolerated. Four fractures were supported in a temporary external splint. Results: The mean age of patients was 80.6 years (range 51–103 years, 52/54 (96% were females. There were no cases of nail related complications and no re-operations were required. One patient was lost to follow up. The 30-day mortality was 5/54 (9.3% and the one year mortality was 17/54 (31.5%. Conclusions: Distal femoral nail fixation provides a good method of fixation allowing immediate mobilisation for this group of patients.

  10. Pendulum Therapy of Molar Distalization in Mixed Dentition.

    Science.gov (United States)

    Patil, Raju Umaji; Prakash, Amit; Agarwal, Anshu

    2016-01-01

    Early and timely pedo-orthodontic treatment is aimed at eliminating the disturbances of skeletal or dentoalveolar development, to harmonize the stomatognathic system before the full eruption of all permanent teeth. The advantages of pendulum appliance are its minimal dependence on patient's compliance (child cooperation), ease of fabrication, onetime activation and adjustment of the springs if necessary to correct minor transverse and vertical molar positions. This article reports a successful treatment method of class II malocclusion with pendulum appliance in mixed dentition phase. Distalization of maxillary molar was done, followed by guidance of canine impaction orthodontically and other dental correction using 0.022 MBT appliances. Posttreatment results were stable and remarkable. How to cite this article: Patil RU, Prakash A, Agarwal A. Pendulum Therapy of Molar Distalization in Mixed Dentition. Int J Clin Pediatr Dent 2016;9(1):67-73.

  11. Unravelling intention: distal intentions increase the subjective sense of agency.

    Science.gov (United States)

    Vinding, Mikkel C; Pedersen, Michael N; Overgaard, Morten

    2013-09-01

    Experimental studies investigating the contribution of conscious intention to the generation of a sense of agency for one's own actions tend to rely upon a narrow definition of intention. Often it is operationalized as the conscious sensation of wanting to move right before movement. Existing results and discussion are therefore missing crucial aspects of intentions, namely intention as the conscious sensation of wanting to move in advance of the movement. In the present experiment we used an intentional binding paradigm, in which we distinguished between immediate (proximal) intention, as usually investigated, and longer standing (distal) intention. The results showed that the binding effect was significantly enhanced for distal intentions compared to proximal intentions, indicating that the former leads to stronger sense of agency. Our finding provides empirical support for a crucial distinction between at least two types of intention when addressing the efficacy of conscious intentions. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Optimal fit of chairside-fabricated distal shoe space maintainer.

    Science.gov (United States)

    Nouri, M R; Kennedy, D B

    2013-10-01

    Premature loss of a primary second molar may lead to space loss in the dental arch. This space loss tends to be more severe in unfavourable malocclusions. The distal shoe space maintainer (DSSM) may be beneficial in controlling the path of eruption of an unerupted permanent first molar from the primary into the early mixed dentition. This article describes the technique for achieving optimal fit of a chairside-fabricated band and DSSM in a single visit by contouring the distal shoe blade, and by extending it to the mesial surface of the permanent first molar. Upon the eruption of the permanent first molar DSSM may be modified to a reverse band-and-loop, or replaced by a lingual holding arch.

  13. Filter and Filter Bank Design for Image Texture Recognition

    Energy Technology Data Exchange (ETDEWEB)

    Randen, Trygve

    1997-12-31

    The relevance of this thesis to energy and environment lies in its application to remote sensing such as for instance sea floor mapping and seismic pattern recognition. The focus is on the design of two-dimensional filters for feature extraction, segmentation, and classification of digital images with textural content. The features are extracted by filtering with a linear filter and estimating the local energy in the filter response. The thesis gives a review covering broadly most previous approaches to texture feature extraction and continues with proposals of some new techniques. 143 refs., 59 figs., 7 tabs.

  14. The effect of distal utility value intervention for students’ learning

    OpenAIRE

    KERA, Masaki; NAKAYA, Motoyuki

    2017-01-01

    The purpose of this study was to determine whether a utility value intervention influenced students’motivation and performance. Specifically, we examined the effect of distal utility value (i.e., the recognition of content usefulness for skill development that can improve daily and future endeavors) instruction in this study.Fifty-one Japanese undergraduate students completed an experimental session in the laboratory, in which they performed a series of logical reasoning problem-solving tasks...

  15. Epidemiology of distal forearm fractures in Oslo, Norway.

    Science.gov (United States)

    Lofthus, C M; Frihagen, F; Meyer, H E; Nordsletten, L; Melhuus, K; Falch, J A

    2008-06-01

    The population of Oslo has the highest incidence of hip fracture reported. The present study shows that the overall incidence of distal forearm fractures in Oslo is higher than in other countries and has not changed significantly when comparing the incidence of 1998/99 with 1979. The population of Oslo has the highest incidence of hip fracture reported. The present study reports the incidence of distal forearm fracture in Oslo and the fracture rates of immigrants. Patients aged > or = 20 years resident in Oslo sustaining a distal forearm fracture in a one-year period in 1998/99 were identified using electronic diagnosis registers, patient protocols, and/or X-ray registers of the clinics in Oslo. Medical records were obtained and the diagnosis verified. The age- and sex-specific incidence rates were calculated and compared with those for 1979. Data on immigrant category and country of origin of the patients were obtained. The age-adjusted fracture rates per 10,000 for the age group > or = 50 years were 109.8 and 25.4 in 1998/99 compared with 108.3 and 23.5 in 1979 for women and men, respectively (n.s.). The relative risk of fracture in Asians was 0.72 (95% CI 0.53-1.00) compared with ethnic Norwegians. The overall incidence of distal forearm fractures in Oslo is higher than in other countries and has not changed significantly when comparing the incidence of 1998/99 with 1979. Furthermore, the present data suggest that Asian immigrants in Oslo have a slightly lower fracture risk than ethnic Norwegians.

  16. Dual-port distal gastrectomy for the early gastric cancer

    OpenAIRE

    Kashiwagi, Hiroyuki; Kumagai, Kenta; Monma, Eiji; Nozue, Mutsumi

    2014-01-01

    Background Although recent trends in laparoscopic procedures have been toward minimizing the number of incisions, four or five ports are normally required to complete laparoscopic gastrectomy because of the complexity of this procedure. Multi-channel ports, such as the SILS port (Covidien, JAPAN), are now available and are crucial for performing single-incision laparoscopic surgery (SILS) or reduced port surgery (RPS). We carried out reduced port distal gastrectomy (RPDG) using a dual-port me...

  17. Factors Associated with Infection Following Open Distal Radius Fractures

    OpenAIRE

    Glueck, Dane A.; Charoglu, Constantine P.; Lawton, Jeffrey N.

    2009-01-01

    Open fractures are often classified according to a system described by Gustilo and Anderson. However, this system was applied to open long bone factures, which may not predict the incidence of infection in open metaphyseal fractures of the upper extremity. Other studies have found that wound contamination and systemic illness were the best predictors of infections in open hand fractures. Our study assessed infection in open distal radius fractures and identifies factors that are associated wi...

  18. Is nonoperative management of partial distal biceps tears really successful?

    Science.gov (United States)

    Bauer, Tyler M; Wong, Justin C; Lazarus, Mark D

    2018-04-01

    The current treatment of partial distal biceps tears is a period of nonoperative management, followed by surgery, if symptoms persist. Little is known about the success rate and outcomes of nonoperative management of this illness. We identified 132 patients with partial distal biceps tears through an International Classification of Diseases, Ninth Revision code query of our institution's database. Patient records were reviewed to abstract demographic information and confirm partial tears of the distal biceps tendon based on clinical examination findings and confirmatory magnetic resonance imaging (MRI). Seventy-four patients completed an outcome survey. In our study, 55.7% of the contacted patients who tried a nonoperative course (34 of 61 patients) ultimately underwent surgery, and 13 patients underwent immediate surgery. High-need patients, as defined by occupation, were more likely to report that they recovered ideally if they underwent surgery, as compared with those who did not undergo surgery (odds ratio, 11.58; P = .0138). For low-need patients, the same analysis was not statistically significant (P = .139). There was no difference in satisfaction scores between patients who tried a nonoperative course before surgery and those who underwent immediate surgery (P = .854). An MRI-diagnosed tear of greater than 50% was a predictor of needing surgery (odds ratio, 3.0; P = .006). This study has identified clinically relevant information for the treatment of partial distal biceps tears, including the following: the failure rate of nonoperative treatment, the establishment of MRI percent tear as a predictor of failing nonoperative management, the benefit of surgery for the high-need occupational group, and the finding that nonoperative management does not negatively affect outcome if subsequent surgery is necessary. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. Characterisation of osseous bodies of the distal phalanx of foals

    International Nuclear Information System (INIS)

    Kaneps, A.J.; O'Brien, T.R.; Redden, R.F.; Stover, S.M.; Pool, R.R.

    1993-01-01

    The distal phalanx and metacarpal physis of both forelimbs of 32 Thoroughbred foals 3-32 weeks of age were radiographed to identify those limbs with osseous bodies at a palmar process (PP) of the distal phalanx. Osseous bodies (ossicles) were identified radiographically in 19% of the foals. Sixteen of the 32 foals were selected for microradiographic and histological evaluation: 6 foals with radiographic evidence of ossicles and 10 foals without. Fourteen ossicles of the PP were observed radiographically. Ossicles were either a triangular bone fragment at the palmar aspect of the distal angle of the PP, or an oblong bone fragment separated from P3 by a radiolucent line extending 1-3 cm from the incisure of the PP to the solar margin. One foal had radiographic evidence of bilateral distal metacarpal physitis. Seventeen of 35 PPs examined microradiographically were considered normal, in that the dorsal and solar cortices were thin with trabecular bone orientated parallel to the cortical surfaces, and there was a depression in the dorsal cortical surface (i.e. parietal sulcus). Abnormal microradiographic findings in the other 18 PPs included a fracture line extending from the dorsal cortical surfaces and trabecular bridging of the fracture gap. The fracture line was often continuous with the parietal sulcus. Microradiographic evidence of a fracture was found in 75% of foals evaluated. Normal histological findings in 16 PPs included thin dorsal and solar cortices with trabeculae orientated parallel to the cortical surfaces, parallel-fibred dense connective tissue attachments of the deep digital flexor tendon to the solar cortical surfaces, and a neurovascular bundle associated with the parietal sulcus

  20. External jig in the placement of distal interlocking screws | Ikem ...

    African Journals Online (AJOL)

    Retrograde (52.2%) was the commonest surgical approach used for femur. The main indication for SIGN interlocking surgery was recent fracture 77.8%. Open reduction 97.8% was the commonest method of reduction used. The mean±SD bone union time was 3.58±0.56 months and range 3-5 months. Distal screw insertion ...

  1. A PROSPECTIVE STUDY OF DISTAL TIBIAL FRACTURES BY MIPO (LCP)

    OpenAIRE

    Chandra Sekharam Naidu; Ch.Murali Krishna; Sankara Rao; Dharma Rao; Ashok Kumar

    2015-01-01

    INTRODUCTION: D istal tibial fractures represent a significant challenge to most of the surgeons even today. They constitute 1 - 10% of all lower extremity fractures . 1 The difficulty in treating the fractures of distal tibial end is exemplif ied by orthopedists, who in the first half of twentieth century, believed these injuries were so severe and fraught with so many complications, that these fractures wer...

  2. Distal renal tubular acidosis in recurrent renal stone formers

    DEFF Research Database (Denmark)

    Osther, P J; Hansen, A B; Røhl, H F

    1989-01-01

    Renal acidification ability was examined in 90 recurrent renal stone formers, using fasting morning urinary pH levels followed by a short ammonium chloride loading test in subjects with pH levels above 6.0. Fifteen patients (16.6%) revealed a distal renal tubular acidification defect: one patient......, this has important therapeutic implications. The pathological sequence in renal stone formers with dRTA is discussed....

  3. Impact of a Nationwide Training Program in Minimally Invasive Distal Pancreatectomy (LAELAPS)

    NARCIS (Netherlands)

    de Rooij, Thijs; van Hilst, Jony; Boerma, Djamila; Bonsing, Bert A.; Daams, Freek; van Dam, Ronald M.; Dijkgraaf, Marcel G.; van Eijck, Casper H.; Festen, Sebastiaan; Gerhards, Michael F.; Koerkamp, Bas Groot; van der Harst, Erwin; de Hingh, Ignace H.; Kazemier, Geert; Klaase, Joost; de Kleine, Ruben H.; van Laarhoven, Cornelis J.; Lips, Daan J.; Luyer, Misha D.; Molenaar, I. Quintus; Patijn, Gijs A.; Roos, Daphne; Scheepers, Joris J.; van der Schelling, George P.; Steenvoorde, Pascal; Vriens, Menno R.; Wijsman, Jan H.; Gouma, Dirk J.; Busch, Olivier R.; Hilal, Mohammed Abu; Besselink, Marc G.; de Boer, Marieke T.

    2016-01-01

    Objective:To study the feasibility and impact of a nationwide training program in minimally invasive distal pancreatectomy (MIDP).Summary of Background Data:Superior outcomes of MIDP compared with open distal pancreatectomy have been reported. In the Netherlands (2005 to 2013) only 10% of distal

  4. Cost-effectiveness of laparoscopic versus open distal pancreatectomy for pancreatic cancer

    NARCIS (Netherlands)

    Gurusamy, Kurinchi Selvan; Riviere, Deniece; van Laarhoven, C. J. H.; Besselink, Marc; Abu-Hilal, Mohammed; Davidson, Brian R.; Morris, Steve

    2017-01-01

    A recent Cochrane review compared laparoscopic versus open distal pancreatectomy for people with for cancers of the body and tail of the pancreas and found that laparoscopic distal pancreatectomy may reduce the length of hospital stay. We compared the cost-effectiveness of laparoscopic distal

  5. Computer tomographic assessment of postoperative peripancreatic collections after distal pancreatectomy.

    Science.gov (United States)

    Uchida, Yuichiro; Masui, Toshihiko; Sato, Asahi; Nagai, Kazuyuki; Anazawa, Takayuki; Takaori, Kyoichi; Uemoto, Shinji

    2018-03-27

    Peripancreatic collections occur frequently after distal pancreatectomy. However, the sequelae of peripancreatic collections vary from case to case, and their clinical impact is uncertain. In this study, the correlations between CT findings of peripancreatic collections and complications after distal pancreatectomy were investigated. Ninety-six consecutive patients who had undergone distal pancreatectomy between 2010 and 2015 were retrospectively investigated. The extent and heterogeneity of peripancreatic collections and background clinicopathological characteristics were analyzed. The extent of peripancreatic collections was calculated based on three-dimensional computed tomography images, and the degree of heterogeneity of peripancreatic collections was assessed based on the standard deviation of their density on computed tomography. Of 85 patients who underwent postoperative computed tomography imaging, a peripancreatic collection was detected in 77 (91%). Patients with either a large extent or a high degree of heterogeneity of peripancreatic collection had a significantly higher rate of clinically relevant pancreatic fistula than those without (odds ratio 5.95, 95% confidence interval 2.12-19.72, p = 0.001; odds ratio 8.0, 95% confidence interval 2.87-24.19, p = 0.0001, respectively). A large and heterogeneous peripancreatic collection was significantly associated with postoperative complications, especially clinically relevant postoperative pancreatic fistula. A small and homogenous peripancreatic collection could be safely observed.

  6. Total elbow arthroplasty for the treatment of distal humeral fractures.

    Science.gov (United States)

    Gallucci, G L; Larrondo Calderón, W; Boretto, J G; Castellaro Lantermo, J A; Terán, J; de Carli, P

    2016-01-01

    To report the clinical-functional outcomes of the treatment of humeral distal fractures with a total elbow prosthesis. This retrospective study was performed in two surgical centres. A total of 23patients were included, with a mean age of 79years, and of which 21 were women. The inclusion criteria were: patients with humeral distal fractures, operated on using a Coonrad-Morrey prosthesis, and with a follow-up of more than one year. According to AO classification, 15fractures were type C3, 7 C2 and 1 A2. All patients were operated on without de-insertion of the extensor mechanism. The mean follow-up was 40 months. Flexor-extension was 123-17°, with a total mobility arc of 106° (80% of the contralateral side). Pain, according to a visual analogue scale was 1. The Mayo Elbow Performance Index (MEPI) was 83 points. Excellent results were obtained in 8 patients, good in 13, medium in 1, and poor in 1. The mean DASH (disability) score was 24 points. Treatment of humeral distal fractures with total elbow arthroplasty could be a good treatment option, but indications must be limited to patients with complex fractures, poor bone quality, with osteoporosis and low functional demands. In younger patients, the use is limited to serious cases where there is no other treatment option. Level of Evidence IV. Copyright © 2016 SECOT. Published by Elsevier Espana. All rights reserved.

  7. Distal antebrachial fractures in toy-breed dogs

    International Nuclear Information System (INIS)

    Muir, P.

    1997-01-01

    Antebrachial fractures account for approximately 17% of all canine fractures, with motor vehicle trauma cited as one of the primary causes. However, antebrachial fractures in toy-breed dogs are often sustained after apparently minimal trauma, such as jumping or falling, and are usually distal. The cause of antebrachial fractures in toy breeds is not well understood. Complications after treatment of distal antebrachial fractures in toy-breed dogs, including delayed union, nonunion, and malunion, are common and are potentially serious because they may necessitate limb amputation. This article reports on distal antebrachial fractures in 26 toy-breed dogs that wee presented to the University of California, Davis, Veterinary Medical Teaching Hospital from April 1987 to March 1996. The author found that (1) these fractures typically occur in growing or adolescent dogs; (2) the presence of complications of union is typically associated with prior treatment using intramedullary pinning or external coaptation; and (3) successful healing of this type of fracture is obtained via rigid stabilization with bone plating in combination with cancellous bone autograft

  8. Suture anchor tenodesis in repair of distal Achilles tendon injuries.

    Science.gov (United States)

    Kiliçoğlu, Onder; Türker, Mehmet; Yildız, Fatih; Akalan, Ekin; Temelli, Yener

    2014-01-01

    Distal Achilles tendon avulsions are in the form of either bony and nonbony avulsion of Achilles tendon from its calcaneal insertion. Four patients with distal Achilles tendon avulsions or ruptures which were treated with tendon to bone repair using suture anchors are presented here. Operated leg was immobilized in above-knee cast for 4 weeks while the patient walked non-weight-bearing. Then, cast was changed to below knee, and full weight-bearing was allowed. Patients underwent gait analysis minimum at first postoperative year. Mean American Orthopedics Foot Ankle Society ankle/hindfoot score of patients at last visit was 88.75 (range 85-100), and Achilles tendon total rupture score was 77.75 (range 58-87). Mean passive dorsiflexion of injured ankles (14° ± 5°) was lower than uninjured ankles (23° ± 9°). All the kinematic parameters of gait analysis were comparable to the uninjured side. Maximum plantar flexion power of injured ankle was 1.40 W/kg, and this was significantly lower than the contralateral side value 2.38 W/kg; (P = 0.0143). There were no visually altered gait or problems in daily life. Suture anchor tenodesis technique of distal Achilles tendon avulsions was successful in achieving durable osteotendinous repairs.

  9. Laparoscopic distal pancreatectomy for adenocarcinoma of the pancreas

    Science.gov (United States)

    Björnsson, Bergthor; Sandström, Per

    2014-01-01

    Since the first report on laparoscopic distal pancreatectomy (LDP) appeared in the 1990s, the procedure has been performed increasingly frequently to treat both benign and malignant lesions of the pancreas. Many earlier publications have shown LDP to be a good alternative to open distal pancreatectomy for benign lesions, although this has never been studied in a prospective, randomized manner. The evidence for the use of LDP to treat adenocarcinoma of the pancreas is not as well established. The purpose of this review is to evaluate the current evidence for LDP in cases of pancreatic adenocarcinoma. We conducted a review of English language publications reporting LDP results between 1990 and 2013. All studies reporting results in patients with histologically proven pancreatic adenocarcinoma were included. Thirty-nine publications were found and included in the results for a total of 309 cases of pancreatic adenocarcinoma (potential double publications were not eliminated). Most LDP procedures are performed in selected cases and generally involve smaller tumors than open distal pancreatectomy (ODP) procedures. Some of the papers report unselected cases and include procedures on larger tumors. The number of lymph nodes harvested using LDP is comparable to the number obtained with ODP, as is the frequency of R0 resections. Current data suggest that similar short term oncological results can be obtained using LDP as those obtained using ODP. PMID:25309072

  10. Importance of early audiologic assessment in distal renal tubular acidosis

    Directory of Open Access Journals (Sweden)

    Elizabeth Norgett

    2010-12-01

    Full Text Available Anand P Swayamprakasam1, Elizabeth Stover1, Elizabeth Norgett1, Katherine G Blake-Palmer1, Michael J Cunningham2, Fiona E Karet11Department of Medical Genetics, Cambridge Institute for Medical Research, Cambridge, UK; 2Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston, MA, USAAbstract: Autosomal recessive distal renal tubular acidosis is usually a severe disease of childhood, often presenting as failure to thrive in infancy. It is often, but not always, accompanied by sensorineural hearing loss, the clinical severity and age of onset of which may be different from the other clinical features. Mutations in either ATP6V1B1 or ATP6V0A4 are the chief causes of primary distal renal tubular acidosis with or without hearing loss, although the loss is often milder in the latter. We describe a kindred with compound heterozygous alterations in ATP6V0A4, where hearing loss was formally diagnosed late in both siblings such that they missed early opportunities for hearing support. This kindred highlights the importance of routine audiologic assessments of all children with distal renal tubular acidosis, irrespective either of age at diagnosis or of which gene is mutated. In addition, when diagnostic genetic testing is undertaken, both genes should be screened irrespective of current hearing status. A strategy for this is outlined.Keywords: sensorineural hearing loss, renal tubular acidosis, recessive, genetics, mutation

  11. Ionotropic GABA Receptors and Distal Retinal ON and OFF Responses

    Directory of Open Access Journals (Sweden)

    E. Popova

    2014-01-01

    Full Text Available In the vertebrate retina, visual signals are segregated into parallel ON and OFF pathways, which provide information for light increments and decrements. The segregation is first evident at the level of the ON and OFF bipolar cells in distal retina. The activity of large populations of ON and OFF bipolar cells is reflected in the b- and d-waves of the diffuse electroretinogram (ERG. The role of gamma-aminobutyric acid (GABA, acting through ionotropic GABA receptors in shaping the ON and OFF responses in distal retina, is a matter of debate. This review summarized current knowledge about the types of the GABAergic neurons and ionotropic GABA receptors in the retina as well as the effects of GABA and specific GABAA and GABAC receptor antagonists on the activity of the ON and OFF bipolar cells in both nonmammalian and mammalian retina. Special emphasis is put on the effects on b- and d-waves of the ERG as a useful tool for assessment of the overall function of distal retinal ON and OFF channels. The role of GABAergic system in establishing the ON-OFF asymmetry concerning the time course and absolute and relative sensitivity of the ERG responses under different conditions of light adaptation in amphibian retina is also discussed.

  12. Three-stage treatment protocol for recalcitrant distal femoral nonunion.

    Science.gov (United States)

    Ma, Ching-Hou; Chiu, Yen-Chun; Tu, Yuan-Kun; Yen, Cheng-Yo; Wu, Chin-Hsien

    2017-04-01

    In this study, we proposed a three-stage treatment protocol for recalcitrant distal femoral nonunion and aimed to analyze the clinical results. We retrospective reviewed 12 consecutive patients with recalcitrant distal femoral nonunion undergoing our three-stage treatment protocol from January 2010 to December 2014 in our institute. The three-stage treatment protocol comprised debridement of the nonunion site, lengthening to eliminate leg length discrepancy, deformity correction, stabilization with a locked plate, filling of the defect with cement spacer for inducing membrane formation, and bone reconstruction using a cancellous bone autograft (Masquelet technique) or free vascularized fibular bone graft. The bone union time, wound complication, lower limbs alignment, amount of lengthening, knee range of motion, and functional outcomes were evaluated. Osseous union with angular deformity lengthening was 5.88 cm (range 3.5-12 cm). Excellent or good outcomes were obtained in 9 patients. Although the current study involved only a small number of patients and the intervention comprised three stages, we believe that such a protocol may be a valuable alternative for the treatment of recalcitrant distal femoral nonunion.

  13. Reconfigurable Mixed Mode Universal Filter

    Directory of Open Access Journals (Sweden)

    Neelofer Afzal

    2014-01-01

    Full Text Available This paper presents a novel mixed mode universal filter configuration capable of working in voltage and transimpedance mode. The proposed single filter configuration can be reconfigured digitally to realize all the five second order filter functions (types at single output port. Other salient features of proposed configuration include independently programmable filter parameters, full cascadability, and low sensitivity figure. However, all these features are provided at the cost of quite large number of active elements. It needs three digitally programmable current feedback amplifiers and three digitally programmable current conveyors. Use of six active elements is justified by introducing three additional reduced hardware mixed mode universal filter configurations and its comparison with reported filters.

  14. Prediction of the filter no-reflow phenomenon in patients with angina pectoris by using multimodality: Magnetic resonance imaging, optical coherence tomography, and serum biomarkers.

    Science.gov (United States)

    Matsumoto, Kenji; Ehara, Shoichi; Hasegawa, Takao; Otsuka, Kenichiro; Yoshikawa, Junichi; Shimada, Kenei

    2016-05-01

    Although the occurrence of no-reflow during percutaneous coronary intervention (PCI) has been shown to be associated with worse short- and long-term clinical outcomes, the clinical relevance of preventing flow deterioration by using the filter-based distal protection devices (DPDs) is controversial. We investigated predictors of the filter no-reflow (FNR) phenomenon during PCI by using multimodality, such as hyperintense plaques (HIPs) in the coronary artery on T1-weighted imaging (T1WI) non-contrast magnetic resonance, plaque composition by using optical coherence tomography (OCT), and serum biomarkers, in patients with angina pectoris. Fifty lesions from 50 patients with angina were examined. All patients underwent T1WI within 24 h before invasive coronary angiography was performed, and preinterventional OCT was performed on a native atherosclerotic culprit lesion. The signal intensity of coronary plaque to cardiac muscle ratio (PMR) was calculated on a standard console of the magnetic resonance system. Of the 50 lesions, 20 lesions showed FNR during PCI, while non-FNR was observed in 30 lesions. A cut-off value >1.85 of PMR had a sensitivity of 65%, a specificity of 93%, a positive predictive value of 87%, and a negative predictive value of 80% for identifying lesions with FNR. Multivariate analysis revealed that the presence of HIPs with PMR >1.85 (p=0.008) was the only independent predictor of the FNR phenomenon during PCI. This study shows that the presence of HIPs with PMR >1.85 on T1WI was a novel independent predictor of the FNR phenomenon during PCI in angina patients. This result may help in identifying high-risk lesions for no-reflow to deploy filter-based DPDs. Copyright © 2015 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  15. Design and full scale test of a sand bed filter

    International Nuclear Information System (INIS)

    Kaercher, M.

    1991-01-01

    All French pressurized water reactor plants are equipped with a containment venting system. this system is designed and implemented by Electricite de France with the technical support of safety authorities (Institute of Protection and Nuclear Safety of Atomic Energy Commission). This paper covers the following items: main assumptions, sizing and design requirements; basic design of the filter resulting from PITEAS R and D program carried out between 1983 and 1989 at Cadarache nuclear center; full scale tests performed in 1990 on FUCHIA loop at Cadarache including description of the loop using plasma torches to generate CsOH aerosols in a steam - air flow, and preliminary results concerning thermohydraulic and thermic behavior under residual power simulated filtration efficiency with CsOH aerosols and iodine; complementary design, including hydrogen risk during condensation period, radiological shieldings of the filter, and heat removal after the filter closure; and conclusion on the validation of the filter

  16. High efficiency particulate removal with sintered metal filters

    International Nuclear Information System (INIS)

    Kirstein, B.E.; Paplawsky, W.J.; Pence, D.T.; Hedahl, T.G.

    1981-01-01

    Because of their particle removal efficiencies and durability, sintered metal filters have been chosen for HEPA filter protection in the off-gas treatment system for the proposed Idaho National Engineering Laboratory Transuranic Waste Treatment Facility. Process evaluation of sintered metal filters indicated a lack of sufficient process design data to assume trouble-free operation. Subsequent pilot-scale testing was performed with fly ash as the test particulate. The test results showed that the sintered metal filters can have an efficiency greater than 0.9999999 for the specific test conditions used. Stable pressure drop characteristics were observed in pulsed and reversed flow blowback modes of operation. Over 4900 hours of operation were obtained with operating conditions ranging up to approximately 90 0 C and 24 volume percent water vapor in the gas stream

  17. High efficiency particulate removal with sintered metal filters

    International Nuclear Information System (INIS)

    Kirstein, B.E.; Paplawsky, W.J.; Pence, D.T.; Hedahl, T.G.

    1981-01-01

    Because of their particle removal efficiencies and durability, sintered metal filters have been chosen for high efficiency particulate air (HEPA) filter protection in the off-gas treatment system for the proposed Idaho National Engineering Laboratory Transuranic Waste Treatment Facility. Process evaluation of sintered metal filters indicated a lack of sufficient process design data to ensure trouble-free operation. Subsequence pilot scale testing was performed with flyash as the test particulate. The test results showed that the sintered metal filters can have an efficiency greater than 0.9999999 for the specific test conditions used. Stable pressure drop characteristics were observed in pulsed and reversed flow blowback modes of operation. Over 4900 hours of operation were obtained with operating conditions ranging up to approximately 90 0 C and 24 vol % water vapor in the gas stream

  18. DSP Control of Line Hybrid Active Filter

    DEFF Research Database (Denmark)

    Dan, Stan George; Benjamin, Doniga Daniel; Magureanu, R.

    2005-01-01

    Active Power Filters have been intensively explored in the past decade. Hybrid active filters inherit the efficiency of passive filters and the improved performance of active filters, and thus constitute a viable improved approach for harmonic compensation. In this paper a parallel hybrid filter...... is studied for current harmonic compensation. The hybrid filter is formed by a single tuned Le filter and a small-rated power active filter, which are directly connected in series without any matching transformer. Thus the required rating of the active filter is much smaller than a conventional standalone...... active filter. Simulation and experimental results obtained in laboratory confirmed the validity and effectiveness of the control....

  19. Multi-filter spectrophotometry simulations

    Science.gov (United States)

    Callaghan, Kim A. S.; Gibson, Brad K.; Hickson, Paul

    1993-01-01

    To complement both the multi-filter observations of quasar environments described in these proceedings, as well as the proposed UBC 2.7 m Liquid Mirror Telescope (LMT) redshift survey, we have initiated a program of simulated multi-filter spectrophotometry. The goal of this work, still very much in progress, is a better quantitative assessment of the multiband technique as a viable mechanism for obtaining useful redshift and morphological class information from large scale multi-filter surveys.

  20. Digital filtering in nuclear medicine

    International Nuclear Information System (INIS)

    Miller, T.R.; Sampathkumaran, S.

    1982-01-01

    Digital filtering is a powerful mathematical technique in computer analysis of nuclear medicine studies. The basic concepts of object-domain and frequency-domain filtering are presented in simple, largely nonmathemaical terms. Computational methods are described using both the Fourier transform and convolution techniques. The frequency response is described and used to represent the behavior of several classes of filters. These concepts are illustrated with examples drawn from a variety of important applications in nuclear medicine

  1. Hydrodynamics of microbial filter feeding.

    Science.gov (United States)

    Nielsen, Lasse Tor; Asadzadeh, Seyed Saeed; Dölger, Julia; Walther, Jens H; Kiørboe, Thomas; Andersen, Anders

    2017-08-29

    Microbial filter feeders are an important group of grazers, significant to the microbial loop, aquatic food webs, and biogeochemical cycling. Our understanding of microbial filter feeding is poor, and, importantly, it is unknown what force microbial filter feeders must generate to process adequate amounts of water. Also, the trade-off in the filter spacing remains unexplored, despite its simple formulation: A filter too coarse will allow suitably sized prey to pass unintercepted, whereas a filter too fine will cause strong flow resistance. We quantify the feeding flow of the filter-feeding choanoflagellate Diaphanoeca grandis using particle tracking, and demonstrate that the current understanding of microbial filter feeding is inconsistent with computational fluid dynamics (CFD) and analytical estimates. Both approaches underestimate observed filtration rates by more than an order of magnitude; the beating flagellum is simply unable to draw enough water through the fine filter. We find similar discrepancies for other choanoflagellate species, highlighting an apparent paradox. Our observations motivate us to suggest a radically different filtration mechanism that requires a flagellar vane (sheet), something notoriously difficult to visualize but sporadically observed in the related choanocytes (sponges). A CFD model with a flagellar vane correctly predicts the filtration rate of D. grandis , and using a simple model we can account for the filtration rates of other microbial filter feeders. We finally predict how optimum filter mesh size increases with cell size in microbial filter feeders, a prediction that accords very well with observations. We expect our results to be of significance for small-scale biophysics and trait-based ecological modeling.

  2. Box-particle intensity filter

    OpenAIRE

    Schikora, Marek; Gning, Amadou; Mihaylova, Lyudmila; Cremers, Daniel; Koch, Wofgang; Streit, Roy

    2012-01-01

    This paper develops a novel approach for multi-target tracking, called box-particle intensity filter (box-iFilter). The approach is able to cope with unknown clutter, false alarms and estimates the unknown number of targets. Furthermore, it is capable of dealing with three sources of uncertainty: stochastic, set-theoretic and data association uncertainty. The box-iFilter reduces the number of particles significantly, which improves the runtime considerably. The low particle number enables thi...

  3. Autoregressive Moving Average Graph Filtering

    OpenAIRE

    Isufi, Elvin; Loukas, Andreas; Simonetto, Andrea; Leus, Geert

    2016-01-01

    One of the cornerstones of the field of signal processing on graphs are graph filters, direct analogues of classical filters, but intended for signals defined on graphs. This work brings forth new insights on the distributed graph filtering problem. We design a family of autoregressive moving average (ARMA) recursions, which (i) are able to approximate any desired graph frequency response, and (ii) give exact solutions for tasks such as graph signal denoising and interpolation. The design phi...

  4. Faraday anomalous dispersion optical filters

    Science.gov (United States)

    Shay, T. M.; Yin, B.; Alvarez, L. S.

    1993-01-01

    The effect of Faraday anomalous dispersion optical filters on infrared and blue transitions of some alkali atoms is calculated. A composite system is designed to further increase the background noise rejection. The measured results of the solar background rejection and image quality through the filter are presented. The results show that the filter may provide high transmission and high background noise rejection with excellent image quality.

  5. Preventive Long-Term Effects of a Topical Film-Forming Medical Device with Ultra-High UV Protection Filters and DNA Repair Enzyme in Xeroderma Pigmentosum: A Retrospective Study of Eight Cases

    Directory of Open Access Journals (Sweden)

    Sandra Giustini

    2014-09-01

    Full Text Available Skin cancer is common in xeroderma pigmentosum (XP due to a DNA repair mechanisms genetic defect. Ultraviolet (UV exposure is the main cause of increased incidence of actinic keratosis (AK, basal cell carcinoma (BCC and squamous cell carcinoma (SCC observed in XP subjects. Photoprotection is therefore a mandatory strategy in order to reduce skin damage. A topical DNA repair enzyme has been shown to slow down the development of skin lesions in XP. However, there are no data regarding the effects of photoprotection combined with DNA repair strategies in this clinical setting. A film-forming medical device containing the DNA repair enzyme photolyase and very high-protection UV filters (Eryfotona AK-NMSC, Ery is currently available. We report retrospective data regarding the use of Ery in 8 patients (5 women, 3 men with a diagnosis of XP treated for at least 12 consecutive months, comparing the rate of new skin lesions (AK, BCC and SCC during active treatment with Ery and during 12 months just before the use of the product. New AK, BCC and SCC mean lesion numbers during the 1-year Ery treatment were 5, 3 and 0, respectively in comparison with 14, 6.8 and 3 lesions, respectively during the 1-year pre-treatment period. Ery use was associated with a 65% reduction in appearance of new AK lesions and with 56 and 100% reductions in the incidence of new BCC and SCC lesions, respectively. These data suggest that topical use of photoprotection and DNA repair enzyme could help lower skin cancer lesions in XP. Control prospective trials are advisable in this clinical setting.

  6. Risk of injury to the sural nerve during posterolateral approach to the distal tibia: An ultrasound simulation study.

    Science.gov (United States)

    Mizia, Ewa; Pękala, Przemysław A; Chomicki-Bindas, Piotr; Marchewka, Wojciech; Loukas, Marios; Zayachkowski, Alexander G; Tomaszewski, Krzysztof A

    2018-05-08

    Introduction When surgeons operate on the foot and ankle, the most common complication that may arise is injury of the cutaneous nerves. The sural nerve (SN) is potentially at risk of being injured when treating fractures involving the distal tibia using the posterolateral approach. The aim of this study was to evaluate how differences in length and position of the surgical treatment of fractures involving the distal tibia can affect the risk of SN injury. Materials and Methods The study involved 40 healthy volunteers (n=80 lower limbs). Ultrasound simulation of each potential surgical incision site was used to locate the SN and to assess the risk of injury. Results The study showed that the SN predominantly travels more posteriorly at levels more proximal from the tip of the lateral malleolus. At these more proximal points of the SN's course, it was proven that there was an overall increased incidence of iatrogenic injury to the SN in incisions made closer to the Achilles tendon. Based on these results, a quasi 3 dimensional figure was created showing the anatomical structures of this region to identify areas at high risk for SN injury. Conclusions By revealing how length and position of the surgical incision can influence the risk of SN injury, we hope to provide information to surgeons on the optimal technique to avoid iatrogenic SN injury while operating on the distal tibia via a posterolateral approach. This article is protected by copyright. All rights reserved. © 2018 Wiley Periodicals, Inc.

  7. Intelligent medical information filtering.

    Science.gov (United States)

    Quintana, Y

    1998-01-01

    This paper describes an intelligent information filtering system to assist users to be notified of updates to new and relevant medical information. Among the major problems users face is the large volume of medical information that is generated each day, and the need to filter and retrieve relevant information. The Internet has dramatically increased the amount of electronically accessible medical information and reduced the cost and time needed to publish. The opportunity of the Internet for the medical profession and consumers is to have more information to make decisions and this could potentially lead to better medical decisions and outcomes. However, without the assistance from professional medical librarians, retrieving new and relevant information from databases and the Internet remains a challenge. Many physicians do not have access to the services of a medical librarian. Most physicians indicate on surveys that they do not prefer to retrieve the literature themselves, or visit libraries because of the lack of recent materials, poor organisation and indexing of materials, lack of appropriate and available material, and lack of time. The information filtering system described in this paper records the online web browsing behaviour of each user and creates a user profile of the index terms found on the web pages visited by the user. A relevance-ranking algorithm then matches the user profiles to the index terms of new health care web pages that are added each day. The system creates customised summaries of new information for each user. A user can then connect to the web site to read the new information. Relevance feedback buttons on each page ask the user to rate the usefulness of the page to their immediate information needs. Errors in relevance ranking are reduced in this system by having both the user profile and medical information represented in the same representation language using a controlled vocabulary. This system also updates the user profiles

  8. [Results After Distal Digital Replantation - Is It Worth The Effort?

    Science.gov (United States)

    Braig, David; Thiele, Jan R; Penna, Vincenzo; Stark, G Björn; Eisenhardt, Steffen U

    2017-02-01

    There are only relative indications for distal digital replantation in zones 1 and 2 according to Tamai. In contrast to primary closure for fingertip amputations, replantation is a complex procedure that requires skills in supermicrosurgical techniques, as vessels with diameters between 0.3-0.8 mm are connected. In addition the time spent in hospital and the time off from work are longer. Distal digital replantation is thus only indicated, if the expected functional and aesthetic benefits surmount those of primary closure. We retrospectively analysed all fingertip amputations in zone 1 and 2 according to Tamai between 9/2009 and 7/2014 where we attempted distal digital replantation. The success of replantation, wound healing and functional results were evaluated according to Yamano. We performed 11 distal digital replantations in the study period. There were 6 total amputations, 4 subtotal amputations and 1 avulsion of the digital pulp. Revascularisation with long-term reattachment of the amputated tissues was possible in 8 cases (73%). In 3 cases (27%) secondary amputation closure was necessary. The mean operating time was 3 h 56 min. 6 patients, which had a successful replantation, were available for follow-up examinations after a mean period of 19 months. 5 patients were satisfied with the result and would again prefer replantation over primary amputation closure. 4 patients reported a good function of the replanted digits and did not complain about any limitations in their use. 2 patients complained about restricted function. All patients could return to their previous places of employment and were free of pain. Of the 12 affected digital nerves 11 nerves had a 2-point discrimination (2-PD) of ≤15 mm, 3 of them had a 2-PD between 7 and 10 mm and 4 of them of replanted digits and nail deformities in 2 patients. Distal digital replantation is complex and technically challenging. It leads to high patient satisfaction with only minimal functional

  9. Device for filtering gaseous media

    International Nuclear Information System (INIS)

    Benzel, M.

    1978-01-01

    The air filter system for gaseous radioactive substances consists of a vertical chamber with filter material (charcoal, e.g. impregnated). On one side of the chamber there is an inlet compartment and an outlet compartment. On the other side a guiding compartment turns the gas flow coming from the natural-air side through the lower part of filter chamber to the upper part of the filter. The gas flow leaves the upper part through the outlet conpartment as cleaned-air flow. The filter material may be filled into the chamber from above and drawn off below. For better utilization of the filter material the filter chamber is separated by means of a wall between the inlet and outlet compartment. This partition wall consist of two sheets arranged one above the other provided with slots which may be superposed in alignment. In this case filter material is tickling from the upper part of the chamber into the lower part avoiding to form a crater in the filter bed. (DG) [de

  10. Spatial filtering with photonic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Maigyte, Lina [Departament de Física i Enginyeria Nuclear, Universitat Politècnica de Catalunya, Rambla Sant Nebridi 22, Terrassa 08222 (Spain); Staliunas, Kestutis [Departament de Física i Enginyeria Nuclear, Universitat Politècnica de Catalunya, Rambla Sant Nebridi 22, Terrassa 08222 (Spain); Institució Catalana de Recerca i Estudis Avançats (ICREA), Pg. Lluís Companys 23, Barcelona 08010 (Spain)

    2015-03-15

    Photonic crystals are well known for their celebrated photonic band-gaps—the forbidden frequency ranges, for which the light waves cannot propagate through the structure. The frequency (or chromatic) band-gaps of photonic crystals can be utilized for frequency filtering. In analogy to the chromatic band-gaps and the frequency filtering, the angular band-gaps and the angular (spatial) filtering are also possible in photonic crystals. In this article, we review the recent advances of the spatial filtering using the photonic crystals in different propagation regimes and for different geometries. We review the most evident configuration of filtering in Bragg regime (with the back-reflection—i.e., in the configuration with band-gaps) as well as in Laue regime (with forward deflection—i.e., in the configuration without band-gaps). We explore the spatial filtering in crystals with different symmetries, including axisymmetric crystals; we discuss the role of chirping, i.e., the dependence of the longitudinal period along the structure. We also review the experimental techniques to fabricate the photonic crystals and numerical techniques to explore the spatial filtering. Finally, we discuss several implementations of such filters for intracavity spatial filtering.

  11. Immobilized Filters for Air Filtration

    National Research Council Canada - National Science Library

    Mahle, John J; Zaiee, Saeed

    2002-01-01

    ... (settling performance) and attrition resistance. The fabricated filter samples will be analyzed in order to determine the physical and chemical factors affecting mechanical strength and chemical filtration...

  12. Adaptive filtering and change detection

    CERN Document Server

    Gustafsson, Fredrik

    2003-01-01

    Adaptive filtering is a classical branch of digital signal processing (DSP). Industrial interest in adaptive filtering grows continuously with the increase in computer performance that allows ever more conplex algorithms to be run in real-time. Change detection is a type of adaptive filtering for non-stationary signals and is also the basic tool in fault detection and diagnosis. Often considered as separate subjects Adaptive Filtering and Change Detection bridges a gap in the literature with a unified treatment of these areas, emphasizing that change detection is a natural extensi

  13. Modelling of a sand bed filter in the cell exhaust air pathway

    International Nuclear Information System (INIS)

    Schmid, M.

    1983-01-01

    Sandbed filters are appropriate incident filters for zircaloy fires, dissolver fires, and explosions. The alternative treatment of these incidents with and without SBF can thus also quantify the safety gain if an SBF is used. The SBF is considered to be a pure incident filter and according to a planning the SBF is by-passed during normal operation. In case of a temperature rise in the cell the by-pass is blocked by a fire protection valve. (orig./DG) [de

  14. UV Blocking Glass: Low Cost Filters for Visible Light Photocatalytic Assessment

    OpenAIRE

    Dunnill, Charles W.

    2014-01-01

    A number of commercially available art protection products have been compared and assessed for their suitability as UV blocking filters in the application of “visible light” photocatalytic research. Many groups claiming visible light photocatalytic success employ filters to block out stray UV radiation in order to justify that their photocatalysts are indeed visible light photocatalysts and not UV light photocatalysts. These filters come in varying degrees of ability and price and many author...

  15. From Microwave Filter to Digital Filter and Back Again

    DEFF Research Database (Denmark)

    Dalby, Arne Brejning

    1989-01-01

    A new very simple state variable flow graph representation for interdigital transmission line bandpass filters is presented, which has led to two important results: 1) A new type of digital filter with properties, that surpass the properties of most other (all pole) digital filtertypes. 2) The st...

  16. AER image filtering

    Science.gov (United States)

    Gómez-Rodríguez, F.; Linares-Barranco, A.; Paz, R.; Miró-Amarante, L.; Jiménez, G.; Civit, A.

    2007-05-01

    Address Event Representation (AER) is an emergent neuromorphic interchip communication protocol that allows real-time virtual massive connectivity among huge number of neurons located on different chips.[1] By exploiting high speed digital communication circuits (with nano-seconds timing), synaptic neural connections can be time multiplexed, while neural activity signals (with mili-seconds timings) are sampled at low frequencies. Neurons generate "events" according to their activity levels. That is, more active neurons generate more events per unit time and access the interchip communication channel more frequently than neurons with low activity. In Neuromorphic system development, AER brings some advantages to develop real-time image processing system: (1) AER represents the information like time continuous stream not like a frame; (2) AER sends the most important information first (although this depends on the sender); (3) AER allows to process information as soon as it is received. When AER is used in artificial vision field, each pixel is considered like a neuron, so pixel's intensity is represented like a sequence of events; modifying the number and the frequency of these events, it is possible to make some image filtering. In this paper we present four image filters using AER: (a) Noise addition and suppression, (b) brightness modification, (c) single moving object tracking and (d) geometrical transformations (rotation, translation, reduction and magnification). For testing and debugging, we use USB-AER board developed by Robotic and Technology of Computers Applied to Rehabilitation (RTCAR) research group. This board is based on an FPGA, devoted to manage the AER functionality. This board also includes a micro-controlled for USB communication, 2 Mbytes RAM and 2 AER ports (one for input and one for output).

  17. Filtering the internet for copyrighted content in Europe

    NARCIS (Netherlands)

    Angelopoulos, C.

    2009-01-01

    One issue that has been frequently discussed in the IRIS plus series is the unauthorised supply of copyright protected works via the Internet. The resulting threat of copyright infringements could, at least partly, be prevented through the use of Internet filters, an option that forms the subject of

  18. Particle Kalman Filtering: A Nonlinear Framework for Ensemble Kalman Filters

    KAUST Repository

    Hoteit, Ibrahim

    2010-09-19

    Optimal nonlinear filtering consists of sequentially determining the conditional probability distribution functions (pdf) of the system state, given the information of the dynamical and measurement processes and the previous measurements. Once the pdfs are obtained, one can determine different estimates, for instance, the minimum variance estimate, or the maximum a posteriori estimate, of the system state. It can be shown that, many filters, including the Kalman filter (KF) and the particle filter (PF), can be derived based on this sequential Bayesian estimation framework. In this contribution, we present a Gaussian mixture‐based framework, called the particle Kalman filter (PKF), and discuss how the different EnKF methods can be derived as simplified variants of the PKF. We also discuss approaches to reducing the computational burden of the PKF in order to make it suitable for complex geosciences applications. We use the strongly nonlinear Lorenz‐96 model to illustrate the performance of the PKF.

  19. Application of DFT Filter Banks and Cosine Modulated Filter Banks in Filtering

    Science.gov (United States)

    Lin, Yuan-Pei; Vaidyanathan, P. P.

    1994-01-01

    None given. This is a proposal for a paper to be presented at APCCAS '94 in Taipei, Taiwan. (From outline): This work is organized as follows: Sec. II is devoted to the construction of the new 2m channel under-decimated DFT filter bank. Implementation and complexity of this DFT filter bank are discussed therein. IN a similar manner, the new 2m channel cosine modulated filter bank is discussed in Sec. III. Design examples are given in Sec. IV.

  20. Fire protection countermeasures for containment ventilation systems

    International Nuclear Information System (INIS)

    Alvares, N.J.; Beason, D.G.; Bergman, W.; Ford, H.W.; Lipska, A.E.

    1980-01-01

    The goal of this project is to find countermeasures to protect HEPA filters in exit ventilation ducts from the heat and smoke generated by fire. Several methods for partially mitigating the smoke exposure to the HEPA filters were identified through testing and analysis. These independently involve controlling the fuel, controlling the fire, and intercepting the smoke aerosol prior to its sorption on the HEPA filter. Exit duct treatment of aerosols is not unusual in industrial applications and involves the use of scrubbers, prefilters, and inertial impaction, depending on the size, distribution, and concentration of the subject aerosol. However, when these unmodified techniques were applied to smoke aerosols from fires on materials, common to experimental laboratories of LLNL, it was found they offered minimal protection to the HEPA filters. Ultimately, a continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. This technique is capable of protecting HEPA filters over the total duration of the test fires. The reason for success involved the modificaton of the prefiltration media. Commercially available filter media has a particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, we laminated rolling filter media with the desired properties. It is not true that the use of rolling prefilters solely to protect HEPA filters from fire-generated smoke aerosols is cost effective in every type of containment system, especially if standard fire-protection systems are available in the space. But in areas of high fire risk, where the potential fuel load is large and ignition sources are plentiful, the complication of a rolling prefilter in exit ventilation ducts to protect HEPA filters from smoke aerosols is definitely justified

  1. 40 CFR 141.562 - My system only has two or fewer filters-is there any special provision regarding individual...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false My system only has two or fewer filters-is there any special provision regarding individual filter turbidity monitoring? 141.562 Section 141.562 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS...

  2. 40 CFR 141.551 - What strengthened combined filter effluent turbidity limits must my system meet?

    Science.gov (United States)

    2010-07-01

    ... effluent turbidity limits must my system meet? 141.551 Section 141.551 Protection of Environment... Effluent Requirements § 141.551 What strengthened combined filter effluent turbidity limits must my system meet? Your system must meet two strengthened combined filter effluent turbidity limits. (a) The first...

  3. The filter fraud: debunking the myth of "Safer" as a key new strategy of tobacco control

    Directory of Open Access Journals (Sweden)

    Alan Blum

    2018-03-01

    Additional research on the potential health and environmental benefits of removing filters from the marketplace should be conducted, aimed at stricter product regulation. Meanwhile, rather than solely continuing to educate the public about the dangers of smoking, public health professionals and clinicians need to better communicate the message that filtered cigarettes do not confer any health protection whatsoever.

  4. Concave distal end of ulna metaphysis alone is not a sign of rickets

    Energy Technology Data Exchange (ETDEWEB)

    Oestreich, Alan E. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, 5031, Cincinnati, OH (United States)

    2015-07-15

    Statements have been made in the literature and in legal testimony that misrepresent the radiographic finding of concave distal end of the ulnar metaphysis. To demonstrate that a concave distal end of the ossified ulna in infancy can be normal. Eighty distal wrists of randomly selected infants in the first year of life with radiographic evidence that ruled out rickets were reviewed. In 16 of the cases (20%), mild or moderate concavity of the distal end of the ulna was seen. An intact metaphyseal collar of distal radius or ulna confirmed the absence of radiographic rickets. The finding of 20% of concave distal ulnas in the first year of life confirms the widely acknowledged statements that concave distal end of the ulna alone is not indicative of rickets. Statements to the contrary are not justified. (orig.)

  5. Concave distal end of ulna metaphysis alone is not a sign of rickets

    International Nuclear Information System (INIS)

    Oestreich, Alan E.

    2015-01-01

    Statements have been made in the literature and in legal testimony that misrepresent the radiographic finding of concave distal end of the ulnar metaphysis. To demonstrate that a concave distal end of the ossified ulna in infancy can be normal. Eighty distal wrists of randomly selected infants in the first year of life with radiographic evidence that ruled out rickets were reviewed. In 16 of the cases (20%), mild or moderate concavity of the distal end of the ulna was seen. An intact metaphyseal collar of distal radius or ulna confirmed the absence of radiographic rickets. The finding of 20% of concave distal ulnas in the first year of life confirms the widely acknowledged statements that concave distal end of the ulna alone is not indicative of rickets. Statements to the contrary are not justified. (orig.)

  6. The ''Nuclear-Karlsruhe'' air-filter system

    International Nuclear Information System (INIS)

    Berliner, P.; Ohlmeyer, M.; Stotz, W.

    1976-01-01

    Increasing requirements for exhaust-air filter systems used in nuclear facilities induced the Gesellschaft fuer Kernforschung to develop the ''Nuclear-Karlsruhe'' HEPA filter system. This novel development has profited by experience gained in previous incidents as well as by maitenance and decontamination work performed with different HEPA filter systems. The proved ''Nuclear-Karlsruhe'' system takes equally into account the demands for optimum safety, maximum efficiency and economy, and is distinguished by the following features: (1) The air current is defected by 180 0 in the casing. Deflection causes quite a number of improvements, results in substantial reduction of space requirements, and avoids the dispersion of pollutants to the clean-air side. Besides, the HEPA filter is protected from damage by condensed particles or foreign materials entrained; (2) The ''Nuclear-Karlsruhe'' system allows gas-tight filter replacement. Special replacement collars have been provided at the casing, which allow the tight fastening of replacement bags which are self-locking. (3) In-place testing in the operating condition can be carried out very conveniently because the air is deflected. Minimum leaks in the filter medium or in the filter gasket can be detected by the high-sensitivity visual oil-thread test, which makes leaks distinctly visible as oil mist threads through a transparent front window provided on the clean-air side. The test takes only some minutes and its sensitivity is hardly matched by any other technique. (4) The clamping mechanism is installed outside the casing, i.e. outside the polluted or aggressive media. The contact force is spring-loaded absolutely uniformly to the circular filter gasket. (5) For practical and econmic reasons the filter casings can be locked individually so as to be gas-tight. (6) The entire system is made of stainless or coated steel and metal parts which are corrosion and fire-resistant. (author)

  7. Filters in Fuzzy Class Theory

    Czech Academy of Sciences Publication Activity Database

    Kroupa, Tomáš

    2008-01-01

    Roč. 159, č. 14 (2008), s. 1773-1787 ISSN 0165-0114 R&D Projects: GA MŠk 1M0572; GA AV ČR KJB100300502 Institutional research plan: CEZ:AV0Z10750506 Keywords : filter * prime filter * fuzzy class theory Subject RIV: BA - General Mathematics Impact factor: 1.833, year: 2008

  8. Derivative free filtering using Kalmtool

    DEFF Research Database (Denmark)

    Bayramoglu, Enis; Hansen, Søren; Ravn, Ole

    2010-01-01

    In this paper we present a toolbox enabling easy evaluation and comparison of different filtering algorithms. The toolbox is called Kalmtool 4 and is a set of MATLAB tools for state estimation of nonlinear systems. The toolbox contains functions for extended Kalman filtering as well as for DD1 fi...

  9. Chopped filter for nuclear spectroscopy

    International Nuclear Information System (INIS)

    Koyama, J.

    1980-12-01

    Some of the theoretical and practical factors affecting the energy resolution of a spectrometry system are considered, specially those related to t he signal-to-noise ratio, and a time-variant filter with the transfer function of the theoretical optimum filter, during its active time, is proposed. A prototype has been tested and experimental results are presented. (Author) [pt

  10. Cluster Based Vector Attribute Filtering

    NARCIS (Netherlands)

    Kiwanuka, Fred N.; Wilkinson, Michael H.F.

    2016-01-01

    Morphological attribute filters operate on images based on properties or attributes of connected components. Until recently, attribute filtering was based on a single global threshold on a scalar property to remove or retain objects. A single threshold struggles in case no single property or

  11. Some arithmetically symmetrical bandpass filters

    Science.gov (United States)

    Paranasi, P.; Roy, S. C. D.

    1981-01-01

    A combination of the conventional and Matthaei lowpass-bandpass transformations is shown to result in some bandpass filters having very good arithmetic symmetry. The technique presented is applicable to the Butterworth and inverse Chebyshev types of magnitude approximations and the Bessel type of delay approximations. It is not valid, however, for the Chebyshev and elliptic varieties of filters.

  12. Properties of auxiliary filtering materials

    Energy Technology Data Exchange (ETDEWEB)

    Rudenko, L.I.; Sklyar, V.T.

    1981-01-01

    The authors have studied the physicochemical and filtering properties of the perlites FP-1 and FP-2, kieselguhr, diatomite, asbestos, wood pulp, and the diatomite powders Spidplace and Saperaid. They propose a classification for filtering materials according to their properties when mechanical impurities are being removed from the additives.

  13. High flow ceramic pot filters

    NARCIS (Netherlands)

    van Halem, D.; van der Laan, H.; Soppe, A. I.A.; Heijman, S.G.J.

    2017-01-01

    Ceramic pot filters are considered safe, robust and appropriate technologies, but there is a general consensus that water revenues are limited due to clogging of the ceramic element. The objective of this study was to investigate the potential of high flow ceramic pot filters to produce more

  14. Mixtures of skewed Kalman filters

    KAUST Repository

    Kim, Hyoungmoon; Ryu, Duchwan; Mallick, Bani K.; Genton, Marc G.

    2014-01-01

    Normal state-space models are prevalent, but to increase the applicability of the Kalman filter, we propose mixtures of skewed, and extended skewed, Kalman filters. To do so, the closed skew-normal distribution is extended to a scale mixture class

  15. Mobile filters in nuclear engineering

    International Nuclear Information System (INIS)

    Meuter, R.

    1979-01-01

    The need for filters with high efficiencies which may be used at any place originated in nuclear power plants. Filters of this type, called Filtermobil, have been developed by Sulzer. They have been used successfully in nuclear plants for several years. (orig.) [de

  16. Implicit LES using adaptive filtering

    Science.gov (United States)

    Sun, Guangrui; Domaradzki, Julian A.

    2018-04-01

    In implicit large eddy simulations (ILES) numerical dissipation prevents buildup of small scale energy in a manner similar to the explicit subgrid scale (SGS) models. If spectral methods are used the numerical dissipation is negligible but it can be introduced by applying a low-pass filter in the physical space, resulting in an effective ILES. In the present work we provide a comprehensive analysis of the numerical dissipation produced by different filtering operations in a turbulent channel flow simulated using a non-dissipative, pseudo-spectral Navier-Stokes solver. The amount of numerical dissipation imparted by filtering can be easily adjusted by changing how often a filter is applied. We show that when the additional numerical dissipation is close to the subgrid-scale (SGS) dissipation of an explicit LES the overall accuracy of ILES is also comparable, indicating that periodic filtering can replace explicit SGS models. A new method is proposed, which does not require any prior knowledge of a flow, to determine the filtering period adaptively. Once an optimal filtering period is found, the accuracy of ILES is significantly improved at low implementation complexity and computational cost. The method is general, performing well for different Reynolds numbers, grid resolutions, and filter shapes.

  17. Tunable Multiband Microwave Photonic Filters

    Directory of Open Access Journals (Sweden)

    Mable P. Fok

    2017-11-01

    Full Text Available The increasing demand for multifunctional devices, the use of cognitive wireless technology to solve the frequency resource shortage problem, as well as the capabilities and operational flexibility necessary to meet ever-changing environment result in an urgent need of multiband wireless communications. Spectral filter is an essential part of any communication systems, and in the case of multiband wireless communications, tunable multiband RF filters are required for channel selection, noise/interference removal, and RF signal processing. Unfortunately, it is difficult for RF electronics to achieve both tunable and multiband spectral filtering. Recent advancements of microwave photonics have proven itself to be a promising candidate to solve various challenges in RF electronics including spectral filtering, however, the development of multiband microwave photonic filtering still faces lots of difficulties, due to the limited scalability and tunability of existing microwave photonic schemes. In this review paper, we first discuss the challenges that were facing by multiband microwave photonic filter, then we review recent techniques that have been developed to tackle the challenge and lead to promising developments of tunable microwave photonic multiband filters. The successful design and implementation of tunable microwave photonic multiband filter facilitate the vision of dynamic multiband wireless communications and radio frequency signal processing for commercial, defense, and civilian applications.

  18. Effects of Na and Ca on particle size; Effect of filtering on UV absorbance

    Data.gov (United States)

    U.S. Environmental Protection Agency — Effects of Na and Ca on particle size; Effect of filtering on UV absorbance. This dataset is associated with the following publication: Bouchard, D., C. Knightes, X....

  19. Hydrodynamics of microbial filter feeding

    DEFF Research Database (Denmark)

    Nielsen, Lasse Tor; Asadzadeh, Seyed Saeed; Dölger, Julia

    2017-01-01

    Microbial filter feeders are an important group of grazers, significant to the microbial loop, aquatic food webs, and biogeochemical cycling. Our understanding of microbial filter feeding is poor, and, importantly, it is unknown what force microbial filter feeders must generate to process adequate......-feeding choanoflagellate Diaphanoeca grandis using particle tracking, and demonstrate that the current understanding of microbial filter feeding is inconsistent with computational fluid dynamics (CFD) and analytical estimates. Both approaches underestimate observed filtration rates by more than an order of magnitude......; the beating flagellum is simply unable to draw enough water through the fine filter. We find similar discrepancies for other choanoflagellate species, highlighting an apparent paradox. Our observations motivate us to suggest a radically different filtration mechanism that requires a flagellar vane (sheet...

  20. Apparatus for filtering radioactive fluids

    International Nuclear Information System (INIS)

    Gischel, E.H.

    1975-01-01

    Apparatus is provided for filtering radioactive particles from the cooling and/or auxiliary process water of a nuclear reactor, or nuclear fuel processing plant, or other installations wherein radioactive fluid systems are known to exist. The apparatus affords disposal of the captured particles in a manner which minimizes the exposure of operating personnel to radioactivity. The apparatus comprises a housing adapted to contain a removable filter cartridge assembly, a valve normally closing the lower end of the housing, an upwardly-open shipping cask located below the valve, and an elongated operating rod assembly projecting upwardly from the filter cartridge assembly and through the upper end of the housing to enable a workman to dismount the filter cartridge assembly from its housing and to lower the filter cartridge assembly through the valve and into the cask from a remote location above the housing. (U.S.)

  1. Vectorization of linear discrete filtering algorithms

    Science.gov (United States)

    Schiess, J. R.

    1977-01-01

    Linear filters, including the conventional Kalman filter and versions of square root filters devised by Potter and Carlson, are studied for potential application on streaming computers. The square root filters are known to maintain a positive definite covariance matrix in cases in which the Kalman filter diverges due to ill-conditioning of the matrix. Vectorization of the filters is discussed, and comparisons are made of the number of operations and storage locations required by each filter. The Carlson filter is shown to be the most efficient of the filters on the Control Data STAR-100 computer.

  2. Tracking speckle displacement by double Kalman filtering

    Institute of Scientific and Technical Information of China (English)

    Donghui Li; Li Guo

    2006-01-01

    @@ A tracking technique using two sequentially-connected Kalman filter for tracking laser speckle displacement is presented. One Kalman filter tracks temporal speckle displacement, while another Kalman filter tracks spatial speckle displacement. The temporal Kalman filter provides a prior for the spatial Kalman filter, and the spatial Kalman filter provides measurements for the temporal Kalman filter. The contribution of a prior to estimations of the spatial Kalman filter is analyzed. An optical analysis system was set up to verify the double-Kalman-filter tracker's ability of tracking laser speckle's constant displacement.

  3. Factors associated with infection following open distal radius fractures.

    Science.gov (United States)

    Glueck, Dane A; Charoglu, Constantine P; Lawton, Jeffrey N

    2009-09-01

    Open fractures are often classified according to a system described by Gustilo and Anderson. However, this system was applied to open long bone fractures, which may not predict the incidence of infection in open metaphyseal fractures of the upper extremity. Other studies have found that wound contamination and systemic illness were the best predictors of infections in open hand fractures. Our study assessed infection in open distal radius fractures and identifies factors that are associated with these infections. We hypothesize that contamination, rather than absolute wound size, is the best predictor of infection associated with open distal radius fractures. A review by CPT code yielded 42 patients with open distal radius fractures between 1997 and 2002 treated at a level one trauma center. Medical records and radiographic follow-up were reviewed to assess the time to irrigation and debridement, the number of debridements in initial treatment period, the method of operative stabilization, the Gustilo and Anderson type of fracture, the Swanson type of fracture, and description of wound contamination. Forty-two patients were followed up for an average of 15 months (range 4 to 68 months). Twenty-four fractures were classified as Gustilo and Anderson type I, ten were type II, and eight were type III, 30 were Swanson type I, and 12 were Swanson type II. Five of the 42 fractures were considered contaminated. Two were exposed to fecal contamination. The others were contaminated with tar, dirt/grass, and gravel, respectively. Three of 42 (7%) fractures developed infections. All three infected cases received a single irrigation and debridement. Two of five contaminated fractures (40%) developed a polymicrobial infection. Both were exposed to fecal contamination and, therefore, considered Swanson type II fractures. They were classified as Gustilo and Anderson type II and IIIB based solely upon the size of the wound. Both required multiple debridements and eventually wrist

  4. Outcomes of Distal Femur Fracture Treated with Dynamic Condylar Screw

    International Nuclear Information System (INIS)

    Razaq, M. N. U.; Muhammad, T.; Ahmed, A.; Adeel, M.; Ahmad, S.; Ahmad, S.; Sultan, S.

    2016-01-01

    Background: Implants for open reduction and internal fixation of distal femoral fracture includes angle blade plate, rush nails, enders nail and interlocking nails. But all these devices are technically demanding and less effective in providing inter-fragmentary compression in osteoporotic bones. These problems can be solved with dynamic condylar screw (DCS).The objective of the study was to determine the frequency of different outcomes of distal femoral fracture treated with dynamic condylar screw Methods: This case series study was carried out in the Department of Trauma and Orthopaedics, Ayub Teaching Hospital Abbottabad from 1st October 2014 to August 2015, after approval of the ethical committee of the institution. Data of all patients with distal femoral fractures aged 20-70 years, recruited through emergency, OPD or consultant clinic collected on a proforma. Standard treatment of trauma was given to the patients. Detailed history was taken including the past medical and surgical history. Detailed examination including air-way, breathing and circulation, general physical examination and abdomino-pelvic examination was done in each patient. Investigations including urinalysis, haemoglobin percent, full blood count, X-ray (both AP and lateral view) of the involved femur (including hip and knee) was done. Results: Mean age of the patients was 43.18±14.647 ranging from 20 to 70 years. Mean duration of hospital stay in days was 2.21±1.111 ranging from 1 to 6 days. Patients follow-up assessment after 4 months of surgery for union of femoral fracture treated with dynamic condylar screw was found in 96 (94.1 percent), wound infection was found in 7 (6.9 percent), knee stiffness was found in 21 (20.6 percent) and limb shortening was found in 7 (6.9 percent). Conclusion: Dynamic condylar screw is an easy, scientifically less difficult and satisfying method of treatment for fractures of femur. (author)

  5. [Lithiasis of the distal ureter: ESWL or URS].

    Science.gov (United States)

    González Enguita, C; Sánchez Gómez, J; Rodríguez-Miñon Cifuentes, J L; Cabrera Pérez, J; Calahorra Fernández, F J; García Cardoso, J; García de la Peña, E; Vela Navarrete, R

    1998-10-01

    A nephritic colic is the clinical picture that evidences the presence of ureteral stones, the natural evolution being their spontaneous passing. Stones in the distal ureter are self-eliminated in about 71-80% cases. The adoption of a "watchful wait" involves an uncertain occupational and medical evolution since, although in some cases the stones will pass with no problems, in other instances they can result in severe, life threatening situations for the patient's health (intractable pain, anuria or sepsis). When a decision is made to treat the condition, there are two choices available: "in situ" SWEL (extracorporeal lithotrity), or URS (ureterorenoscopy), long-standing conflicting techniques each with its own advantages and disadvantages, which should now be considered complementary. SWEL's major disadvantage is the number of repetitions required and the long wait, sometimes even months, until the last fragment is passed. The greater strength of URS is that it can be resolutive in just one episode (95% cases), thus avoiding the obstruction problems that can arise after SWEL. In the Lithiasis-Lithotrity Unit of FJD, SWEL is the first therapeutical option for the treatment of stones in the distal ureter. SWEL and URS are equally likely to be performed although SWEL is the initial choice for efficiency reasons that are explained. We achieve 93.6% positive results with a 1.82% re-SWEL rate (retreatment), 0.60 coefficient of efficiency (EQ) and 0.69 modified coefficient of efficiency (EQM) (Chart). No serious complications were recorded. Morbidity is variable with little clinical significance. Distal ureter lithiasis can be treated with either URS and SWEL, both considered "different and complementary". The choice in each particular case and within each hospital will depend on availability of means to perform one or the other, equipment's efficiency, skill of the urologist, patient's preference and cost of each treatment.

  6. Clinicopathologic characteristics and prognosis of proximal and distal gastric cancer

    Directory of Open Access Journals (Sweden)

    Yu X

    2018-02-01

    Full Text Available Xuefeng Yu,1,* Fulan Hu,2,* Chunfeng Li,1 Qiang Yao,1 Hongfeng Zhang,1 Yingwei Xue1 1Department of Gastrointestinal Surgery, Harbin Medical University Cancer Hospital, Harbin Medical University, Harbin, China; 2Department of Epidemiology, Public Health College, Harbin Medical University, Harbin, China *These authors contributed equally to this work Background and objectives: The dismal prognosis of gastric cancer patients is a global problem. We aim to evaluate the clinicopathologic features and prognostic factors of proximal and distal gastric cancer.Materials and methods: Gastric cancer cases diagnosed and treated at the same surgical unit between 2007 and 2010 were reviewed. Follow-up data from all patients were collected for at least 5 years until 2015. A total of 964 patients were studied (distal gastric cancer [DG], n=777 and proximal gastric cancer [PG], n=187.Results: DG patients had a relatively higher percentage of females, more thorough therapy (R0 [D0/D1/D2], fewer combined organ resections, younger age, smaller tumors (<5 cm, shorter surgery durations, less blood loss during surgery, and a relatively lower percentage of nodal metastases and a TNM stage of 4 (p<0.05. A significantly higher 5-year survival rate was observed in DG patients compared to PG patients (DG: 51%, PG: 28%; p<0.001. A multivariate analysis demonstrated that tumor size, blood loss during surgery, surgery approach of lymph node dissection, treatment with palliative surgery, histopathologic type, TNM stage, and tumor location were independent predictors of poor outcome.Conclusion: The different characteristics and prognosis of DG and PG cases have implications for the development of guiding strategies for a surgical program and assessment of prognosis of gastric cancer patients based on tumor location. Keywords: gastric cancer, tumor location, clinicopathologic features, prognosis, distal gastric cancer, proximal gastric cancer 

  7. Outcome Assessment after Aptis Distal Radioulnar Joint (DRUJ Implant Arthroplasty

    Directory of Open Access Journals (Sweden)

    Amir Reza Kachooei

    2014-09-01

    Full Text Available Background:  Conventional treatments after complicated injuries of the distal radioulnar joint (DRUJ such as Darrach and Kapandji-Sauvé procedures have many drawbacks, which may eventually lead to a painful unstable distal ulna.  The development of DRUJ prosthesis has significantly evolved over the past years. In this study, we assessed the outcome results of patients after DRUJ implant arthroplasty using the Aptis (Scheker prosthesis. Methods: We identified 13 patients with 14 prosthesis during the past 10 years. Patients underwent DRUJ arthroplasty due to persistent symptoms of instability, chronic pain, and stiffness. Records and follow-up visits were reviewed to find the final post-operative symptoms, pain, range of motion, and grip strength with a mean follow-up of 12 months (range: 2-25 months. Also, patients were contacted prospectively by phone in order to  minister the disabilities of the armshoulder and hand (DASH, patient rated wrist evaluation (PRWE, and visual analogue scale (VAS, and to interview regarding satisfaction and progress in daily activities. Eleven patients out of 13 could be reached with a median followup time of 60 months (range: 2 to 102 months.  Results: No patient required removal of the prosthesis. Only two patients underwent secondary surgeries in which both required debridement of the screw tip over the radius. The median DASH score, PRWE score, VAS, and satisfaction were 1.3, 2.5, 0, and 10, respectively. The mean range of flexion, extension, supination, and pronation was 62, 54, 51, and 64, respectively. Conclusions: Distal radioulnar joint injuries are disabling and patients usually undergo one or more salvage surgeries prior to receiving an arthroplasty. The Scheker prosthesis has shown satisfactory results with 100% survival rate in all reports. The constrained design of this prosthesis gives enough stability to prevent painful subluxation.

  8. Medical expulsive treatment of distal ureteral stone using tamsulosin

    International Nuclear Information System (INIS)

    Ahmad, H.; Azim, W.; Akmal, M.; Murtaza, B.

    2015-01-01

    Many minimally invasive interventional techniques as well as expectant treatments exist for the management of lower ureteric calculi. This study was conducted to evaluate the efficacy of tamsulosin as an expulsive pharmacologic therapy for the treatment of distal ureteral stone. Methods: This randomized control trial included 100 patients over 18 years of age with stone Size = 8mm in distal 1/3 of ureter. Patients were randomly assigned into two groups (A and B). Group A Patients were given Capsule Tamsulosin 0.4 mg, 1 daily up to 4 weeks while group B patients were given placebo, 1 Capsule daily up to 4 weeks. The primary endpoint was expulsion rate. A written informed consent was taken from all the patients. Expulsion time, need for analgesics, need for hospitalization and drug side effects were secondary endpoints. Results: A total of 49 patients in group A and 48 patients in group B reported back, therefore 97 out of 100 patients were evaluated. Mean age of the patients was 36.34 years (range 18-57 years). Mean stone size was 5.78 mm (range 4-8 mm) in greatest dimension. A stone expulsion rate of 85.71% (42 patients) was noted in group A and 54.20% (26 patients) in group B. Group A revealed a statistically significant advantage in term of stone expulsion rate (p=0.032). Considering expulsion time in days group A showed statistically significant advantage (p=0.015). Regarding age, sex, stone size and stone lateralization (right/left), there was no significant difference between the group A and B. No drug side effects were noted in both the groups. Conclusion: By using tamsulosin a higher stone expulsion rates can be achieved in a shorter time. More randomized control trials are required to establish tamsulosin as a standard medical expulsive treatment for small distal ureteric calculus. (author)

  9. Prevention of distal extension cantilever fracture in mandibular overdentures.

    Science.gov (United States)

    Quirynen, Thomas; Quirynen, Marc; Duyck, Joke

    2015-09-01

    Fractures of distal bar extensions, supporting a mandibular overdenture, do occur with significant functional and economic consequences for the patient. This study therefore aims to evaluate the effect of different bar cross-sectional shapes and surfaces, bar extension lengths and the placement of a support rib under the distal bar extension on fracture resistance. The 2nd moment area and static strength were calculated for 11 frequently used bar designs using finite element analysis (FEA). For two specific designs (Ackermann round Ø 1.8mm and Dolder-Y macro, the former with and without a support rib) additional physical static and fatigue strength tests were included. The FEA static strength data corresponded well to the 2nd moment area (a similar ranking when maximum allowed force was considered). The application of a rib support (Ackermann Ø 1.8mm) and limitations of the bar extension length (6mm for the Ackermann Ø 1.8mm, 8mm for the Dolder-Y macro) allowed the bars to exceed 5 × 10(6) cycles of 120 and 250N, respectively, before fracture. The region of highest stresses in FEA corresponded well with the locations of the fractures observed in static- and fatigue-testing. With some simple guidelines/modifications, the number of bar extension fractures can be reduced significantly. This study focusses on distal bar extensions which improve the positioning of an implant supported overdenture. By combining laboratory testing and finite element simulations we aim to: (1) explain why fractures occur (dependent on physical characteristics of the bar), and (2) give clinical guidelines on how to prevent such fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Fractal analysis of bone architecture at distal radius

    International Nuclear Information System (INIS)

    Tomomitsu, Tatsushi; Mimura, Hiroaki; Murase, Kenya; Sone, Teruki; Fukunaga, Masao

    2005-01-01

    Bone strength depends on bone quality (architecture, turnover, damage accumulation, and mineralization) as well as bone mass. In this study, human bone architecture was analyzed using fractal image analysis, and the clinical relevance of this method was evaluated. The subjects were 12 healthy female controls and 16 female patients suspected of having osteoporosis (age range, 22-70 years; mean age, 49.1 years). High-resolution CT images of the distal radius were acquired and analyzed using a peripheral quantitative computed tomography (pQCT) system. On the same day, bone mineral densities of the lumbar spine (L-BMD), proximal femur (F-BMD), and distal radius (R-BMD) were measured by dual-energy X-ray absorptiometry (DXA). We examined the correlation between the fractal dimension and six bone mass indices. Subjects diagnosed with osteopenia or osteoporosis were divided into two groups (with and without vertebral fracture), and we compared measured values between these two groups. The fractal dimension correlated most closely with L-BMD (r=0.744). The coefficient of correlation between the fractal dimension and L-BMD was very similar to the coefficient of correlation between L-BMD and F-BMD (r=0.783) and the coefficient of correlation between L-BMD and R-BMD (r=0.742). The fractal dimension was the only measured value that differed significantly between both the osteopenic and the osteoporotic subjects with and without vertebral fracture. The present results suggest that the fractal dimension of the distal radius can be reliably used as a bone strength index that reflects bone architecture as well as bone mass. (author)

  11. Development of the code for filter calculation

    International Nuclear Information System (INIS)

    Gritzay, O.O.; Vakulenko, M.M.

    2012-01-01

    This paper describes a calculation method, which commonly used in the Neutron Physics Department to develop a new neutron filter or to improve the existing neutron filter. This calculation is the first step of the traditional filter development procedure. It allows easy selection of the qualitative and quantitative contents of a composite filter in order to receive the filtered neutron beam with given parameters

  12. Lesiones de la sindesmosis tibioperonea distal: Review article

    OpenAIRE

    Álvarez López, Alejandro; Rodríguez Rodríguez, Eugenio; García Lorenzo, Yenima; Muñoz Infante, Arnaldo

    2008-01-01

    Se realizó una revisión bibliográfica sobre las lesiones traumáticas de la articulación tibioperonea distal. Se recuerda y actualiza sobre aspectos como: anatomía, mecanismo de producción y cuadro clínico. Reciben especial énfasis los estudios imagenológicos y se subraya el uso e interpretación de la radiografía simple. Para terminar esta revisión se exponen las variantes de tratamiento tanto para las lesiones ligamentosas aisladas o asociadas a fractura del tobillo y su manejo posoperatorio....

  13. Paediatric post-traumatic cortical defects of the distal radius

    International Nuclear Information System (INIS)

    Roach, Richard T.; Summers, Bruce N.; Cassar-Pullicino, Victor

    2002-01-01

    Paediatric post-traumatic cortical defects, although rare, are predominately seen affecting the distal radius following a greenstick or torus fracture. We review the literature and present a further two cases supported by CT and MRI. Images from an acute greenstick fracture are also presented to help understand the pathogenesis. Defects are typically solitary on plain radiographs and are usually noticed late, proximal to the site of compression. They are non-expansile in an otherwise healthy child. CT and MRI may reveal smaller multiple subperiosteal defects. Typical defects require no further management other than reassurance and advice that they may occasionally cause discomfort but resolve with time. (orig.)

  14. Proximal and distal adjustments of reaching behavior in preterm infants.

    Science.gov (United States)

    de Toledo, Aline Martins; Soares, Daniele de Almeida; Tudella, Eloisa

    2011-01-01

    The authors aimed to investigate proximal and distal adjustments of reaching behavior and grasping in 5-, 6-, and 7-month-old preterm infants. Nine low-risk preterm and 10 full-term infants participated. Both groups showed the predominance of unimanual reaching, an age-related increase in the frequency of vertical-oriented and open hand movement, and also an increase in successful grasping from 6 to 7 months. The frequency of open hand was higher in the preterm group at 6 months. Intrinsic restrictions imposed by prematurity did not seem to have impaired reaching performance of preterm infants throughout the months of age.

  15. Perimenopausal risk of falling and incidence of distal forearm fracture.

    OpenAIRE

    Winner, S. J.; Morgan, C. A.; Evans, J. G.

    1989-01-01

    A postal survey of 2000 women and 2000 men sampled from the electoral roll in Oxford was undertaken to ascertain whether changes with age in the risk of falling might explain the stepwise increases in age specific incidence rates of distal forearm fracture which occur in women at around the age of 50. Corrected response rates were 83% for women and 72% for men. In women, but not in men, there was a rise in the risk of falling from 45 years, peaking in the 55-59 year age group, and sinking to ...

  16. Giant cells tumor of radius distal end and bone reconstruction

    International Nuclear Information System (INIS)

    La O Duran, Eldis; Monzon Fernandez, Abel Nicolas; Sanz Delgado, Licett

    2009-01-01

    This is the case of a black women aged 40 presenting with a tumor of distal end of right radium with histological diagnosis of low-grade malignancy giant cells tumor and proposal of limb amputation. A conservative surgery was performed with a two-steps total exeresis of lesion sparing the oncologic margin. A fibular free-graft was used and wrist arthrodesis and internal fixation of graft using AO system. There was a good graft consolidation and an active incorporation of patient to social activities. The diagnosis, treatment, follow-up, rehabilitation and case prognosis are exposed

  17. The filter of choice: filtration method preference among injecting drug users

    Directory of Open Access Journals (Sweden)

    Keijzer Lenneke

    2011-08-01

    Full Text Available Abstract Background Injection drug use syringe filters (IDUSF are designed to prevent several complications related to the injection of drugs. Due to their small pore size, their use can reduce the solution's insoluble particle content and thus diminish the prevalence of phlebitis, talcosis.... Their low drug retention discourages from filter reuse and sharing and can thus prevent viral and microbial infections. In France, drug users have access to sterile cotton filters for 15 years and to an IDUSF (the Sterifilt® for 5 years. This study was set up to explore the factors influencing filter preference amongst injecting drug users. Methods Quantitative and qualitative data were gathered through 241 questionnaires and the participation of 23 people in focus groups. Results Factors found to significantly influence filter preference were duration and frequency of injecting drug use, the type of drugs injected and subculture. Furthermore, IDU's rationale for the preference of one type of filter over others was explored. It was found that filter preference depends on perceived health benefits (reduced harms, prevention of vein damage, protection of injection sites, drug retention (low retention: better high, protective mechanism against the reuse of filters; high retention: filter reuse as a protective mechanism against withdrawal, technical and practical issues (filter clogging, ease of use, time needed to prepare an injection and believes (the conviction that a clear solution contains less active compound. Conclusion It was concluded that the factors influencing filter preference are in favour of change; a shift towards the use of more efficient filters can be made through increased availability, information and demonstrations.

  18. On-line filtering

    International Nuclear Information System (INIS)

    Verkerk, C.

    1978-01-01

    Present day electronic detectors used in high energy physics make it possible to obtain high event rates and it is likely that future experiments will face even higher data rates than at present. The complexity of the apparatus increases very rapidly with time and also the criteria for selecting desired events become more and more complex. So complex in fact that the fast trigger system cannot be designed to fully cope with it. The interesting events become thus contaminated with multitudes of uninteresting ones. To distinguish the 'good' events from the often overwhelming background of other events one has to resort to computing techniques. Normally this selection is made in the first part of the analysis of the events, analysis normally performed on a powerful scientific computer. This implies however that many uninteresting or background events have to be recorded during the experiment for subsequent analysis. A number of undesired consequences result; and these constitute a sufficient reason for trying to perform the selection at an earlier stage, in fact ideally before the events are recorded on magnetic tape. This early selection is called 'on-line filtering' and it is the topic of the present lectures. (Auth.)

  19. Fire protection countermeasures for containment ventilation systems

    International Nuclear Information System (INIS)

    Alvares, N.; Beason, D.; Bergman, V.; Creighton, J.; Ford, H.; Lipska, A.

    1980-01-01

    The goal of this project is to find countermeasures to protect High Efficiency Particulate Air (HEPA) filters, in exit ventilation ducts, from the heat and smoke generated by fire. Initially, methods were developed to cool fire-heated air by fine water spray upstream of the filters. It was recognized that smoke aerosol exposure to HEPA filters could also cause disruption of the containment system. Through testing and analysis, several methods to partially mitigate the smoke exposure to the HEPA filters were identified. A continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. The technique is capable of protecting HEPA filters over the total time duration of the test fires. The reason for success involved the modification of the prefiltration media. Commercially available filter media has particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, rolling filter media were laminated with the desired properties. The approach was Edisonian, but truncation in short order to a combination of prefilters was effective. The application of this technique was qualified, since it is of use only to protect HEPA filters from fire-generated smoke aerosols. It is not believed that this technique is cost effective in the total spectrum of containment systems, especially if standard fire protection systems are available in the space. But in areas of high-fire risk, where the potential fuel load is large and ignition sources are plentiful, the complication of a rolling prefilter in exit ventilation ducts to protect HEPA filters from smoke aerosols is definitely justified

  20. Degradation of Organic UV filters in Chlorinated Seawater Swimming Pools: Transformation Pathways and Bromoform Formation.

    Science.gov (United States)

    Manasfi, Tarek; Coulomb, Bruno; Ravier, Sylvain; Boudenne, Jean-Luc

    2017-12-05

    Organic ultraviolet (UV) filters are used in sunscreens and other personal-care products to protect against harmful effects of exposure to UV solar radiation. Little is known about the fate of UV filters in seawater swimming pools disinfected with chlorine. The present study investigated the occurrence and fate of five commonly used organic UV filters, namely dioxybenzone, oxybenzone, avobenzone, 2-ethylhexyl-4-methoxycinnamate, and octocrylene, in chlorinated seawater swimming pools. Pool samples were collected to monitor the variation of UV filter concentrations during pool opening hours. Furthermore, laboratory-controlled chlorination experiments were conducted in seawater spiked with UV filters to investigate the reactivity of UV filters. Extracts of chlorination reaction samples were analyzed using high-resolution mass spectrometry and electron-capture detection to identify the potentially formed byproducts. In the collected pool samples, all the UV filters except dioxybenzone were detected. Chlorination reactions showed that only octocrylene was stable in chlorinated seawater. The four reactive UV filters generated brominated transformation products and disinfection byproducts. This formation of brominated products resulted from reactions between the reactive UV filters and bromine, which is formed rapidly when chlorine is added to seawater. Based on the identified byproducts, the transformation pathways of the reactive UV filters were proposed for the first time. Bromoform was generated by all the reactive UV filters at different yields. Bromal hydrate was also detected as one of the byproducts generated by oxybenzone and dioxybenzone.

  1. Investigation of cooling methods and thickness considerations in the filter/window assembly for synchrotron radiation beamlines

    International Nuclear Information System (INIS)

    Wang, Z.; Kuzay, T.M.; Hahn, U.

    1993-01-01

    Synchrotron x-ray windows are vacuum separators and are usually made of thin beryllium metal. Filters are provided upstream to absorb the soft x-rays so that the window can be protected from overheating, which could result in failure. The filters are made of thin carbon products or sometimes beryllium, the same material as the window. When the synchrotron x-rays pass through a filter or window, part of the photons will be absorbed by the filter or window. The absorbed photons cause heat to build up within the filter or window. Successful filter and window designs should effectively dissipate the heat generated by the absorbed photons and guarantee the safety of the filter and window. The cooling methods typically used in a filter or window design are conduction and radiation cooling or a combination of the two. The different cooling methods were first examined with regard to efficiency and effectiveness in different temperature ranges. Analysis results are presented for temperature distribution and corresponding thermal stresses in the filter and window. Another important issue to be resolved in designing a filter/window assembly is how to select the thickness of the filters and windows. This paper focuses on the criteria for choosing the thickness of a filter: whether it is better to use a few thick filters or a series of thin ones; how to determine the minimum/maximum thickness; and the difference in thickness considerations for the window versus the filter. Numerical investigations are presented

  2. Cost-effectiveness of laparoscopic versus open distal pancreatectomy for pancreatic cancer.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Riviere, Deniece; van Laarhoven, C J H; Besselink, Marc; Abu-Hilal, Mohammed; Davidson, Brian R; Morris, Steve

    2017-01-01

    A recent Cochrane review compared laparoscopic versus open distal pancreatectomy for people with for cancers of the body and tail of the pancreas and found that laparoscopic distal pancreatectomy may reduce the length of hospital stay. We compared the cost-effectiveness of laparoscopic distal pancreatectomy versus open distal pancreatectomy for pancreatic cancer. Model based cost-utility analysis estimating mean costs and quality-adjusted life years (QALYs) per patient from the perspective of the UK National Health Service. A decision tree model was constructed using probabilities, outcomes and cost data from published sources. A time horizon of 5 years was used. One-way and probabilistic sensitivity analyses were undertaken. The probabilistic sensitivity analysis showed that the incremental net monetary benefit was positive (£3,708.58 (95% confidence intervals (CI) -£9,473.62 to £16,115.69) but the 95% CI includes zero, indicating that there is significant uncertainty about the cost-effectiveness of laparoscopic distal pancreatectomy versus open distal pancreatectomy. The probability laparoscopic distal pancreatectomy was cost-effective compared to open distal pancreatectomy for pancreatic cancer was between 70% and 80% at the willingness-to-pay thresholds generally used in England (£20,000 to £30,000 per QALY gained). Results were sensitive to the survival proportions and the operating time. There is considerable uncertainty about whether laparoscopic distal pancreatectomy is cost-effective compared to open distal pancreatectomy for pancreatic cancer in the NHS setting.

  3. Regenerative-filter-incinerator device

    Energy Technology Data Exchange (ETDEWEB)

    Rosebrock, T.L.

    1977-10-18

    A regenerative-filter-incinerator device, for use in the exhaust system of a diesel engine, includes a drum-like regenerative-heat exchanger-filter assembly rotatably mounted within a housing that is adapted to be installed directly in the exhaust gas stream discharged from a diesel engine as close to the engine as possible. The regenerative-heat exchanger-filter assembly provides an inner chamber which serves as a reaction chamber for the secondary combustion of exhaust gases including particulates discharged from the engine. The regenerative-heat exchanger-filter assembly includes separately rotatable heat exchange-filter elements pervious to radial flow of fluid therethrough and adapted to filter out particulates from the exhaust gases and to carry them into the reaction chamber. During engine operation, the reaction chamber is provided with a quantity of heat, as necessary, to effect secondary combustion of the exhaust gases and particulates by means of an auxiliary heat source and the heat generated within the reaction chamber is stored in the individual heat exchange-filter elements during the discharge of exhaust gases therethrough from the reaction chamber and this heat is then transferred to the inflowing volume of the exhaust gases so that, in effect, exhaust gas is discharged from the device at substantially the same temperature as it was during its inlet into the device from the engine.

  4. Correction of Hallux Valgus Interphalangeus With an Osteotomy of the Distal End of the Proximal Phalanx (Distal Akin Osteotomy).

    Science.gov (United States)

    Vander Griend, Robert

    2017-02-01

    Operative correction of a symptomatic hallux valgus interphalangeus (HVI) deformity is often achieved with an osteotomy at the proximal end of the proximal phalanx (Akin osteotomy). However, the apex of the typical HVI deformity (center of rotation angle) is at the interphalangeal joint of the hallux. This study was done to evaluate the results of performing a medial closing wedge osteotomy at the distal end of the proximal phalanx. Thirty-three patients (33 feet) underwent an osteotomy at the distal end of the proximal phalanx for correction of HVI. All of the patients had other forefoot deformities which were corrected at the same time. Eight of these were revision procedures of prior forefoot operations. The length of follow-up was determined by the associated procedures with a minimum follow-up of 4 months. The preoperative hallux valgus interphalangeus angle averaged 16 degrees of valgus (range 7-32 degrees) and was corrected to an average of 2 degrees of valgus (range 5 degrees valgus to 5 degrees varus). All of the patients were satisfied with the postoperative appearance and function of the first toe. Because of simultaneous correction of numerous other forefoot problems, it was not possible to specifically isolate or evaluate the effects and benefits of this osteotomy using outcomes measures. There was one intraoperative complication resulting in a fracture extending into the adjacent IP joint. Correction of an HVI deformity can be achieved with an osteotomy at the distal end of the proximal phalanx. This was a safe technique with few complications and with good results in terms of both correction and patient satisfaction. Level IV, retrospective case series.

  5. Factors Influencing HEPA Filter Performance

    International Nuclear Information System (INIS)

    Parsons, M.S.; Waggoner, Ch.A.

    2009-01-01

    Properly functioning HEPA air filtration systems depend on a variety of factors that start with the use of fully characterized challenge conditions for system design and then process control during operation. This paper addresses factors that should be considered during the design phase as well as operating parameters that can be monitored to ensure filter function and lifetime. HEPA filters used in nuclear applications are expected to meet design, fabrication, and performance requirements set forth in the ASME AG-1 standard. The DOE publication Nuclear Air Cleaning Handbook (NACH) is an additional guidance document for design and operation HEPA filter systems in DOE facilities. These two guidelines establish basic maximum operating parameters for temperature, maximum aerosol particle size, maximum particulate matter mass concentration, acceptable differential pressure range, and filter media velocity. Each of these parameters is discussed along with data linking variability of each parameter with filter function and lifetime. Temporal uncertainty associated with gas composition, temperature, and absolute pressure of the air flow can have a direct impact on the volumetric flow rate of the system with a corresponding impact on filter media velocity. Correlations between standard units of flow rate (standard meters per minute or cubic feet per minute) versus actual units of volumetric flow rate are shown for variations in relative humidity for a 70 deg. C to 200 deg. C temperature range as an example of gas composition that, uncorrected, will influence media velocity. The AG-1 standard establishes a 2.5 cm/s (5 feet per minute) ceiling for media velocities of nuclear grade HEPA filters. Data are presented that show the impact of media velocities from 2.0 to 4.0 cm/s media velocities (4 to 8 fpm) on differential pressure, filter efficiency, and filter lifetime. Data will also be presented correlating media velocity effects with two different particle size

  6. Filters for radioactive liquid wastes

    International Nuclear Information System (INIS)

    Koshiba, Yukihiko; Kawashima, Akio

    1980-01-01

    In the crud generated in the reactor cooling water for nuclear power plants, iron oxides (hematite and magnetite) are contained as the main components, and also Co, Mn, Fe, Cr exist as radioactive nuclides. A new filter to separate these cruds, nuclepore membrane filter (NPMF), was investigated for its adaptability, and has been adopted as a practical filter for radioactive liquid wastes. The NPMF has such features as the possibility of complete automation of operation, no generation of secondary wastes, and easy maintenance, because the NPMF has uniform circular holes in poly-carbonate thin films, and shows the properties of stable filtering of particulates, capability of back washing, and others. The elements mounted in a practical system have such construction that the membrane is cut in the form of doughnut, and sandwiched with 100 mesh polyester nets (spacer); the obtained unit filter (cassette) is mounted on the stackable plate of the same size; and 80 pieces of this cassette are formed in a filter of 4 m 2 filtering area. The performance varies with the properties of suspended matters and the turbidity of wastes. For example, the filtered liquid of 0.1 ppm or less can be obtained when the 1 μm filter material is used to treat the liquid waste containing 1 to 100 ppm suspended matters. Usually back washed water is produced by about 1/100 of treated liquid wastes. The lifetime of the membrane is expected to be 1 or 2 years if crud is the main component. (Wakatsuki, Y.)

  7. Comparison of 3 Minimally Invasive Methods for Distal Tibia Fractures.

    Science.gov (United States)

    Fang, Jun-Hao; Wu, Yao-Sen; Guo, Xiao-Shan; Sun, Liao-Jun

    2016-07-01

    This study compared the results of external fixation combined with limited open reduction and internal fixation (EF + LORIF), minimally invasive percutaneous plate osteosynthesis (MIPPO), and intramedullary nailing (IMN) for distal tibia fractures. A total of 84 patients with distal tibia shaft fractures were randomized to operative stabilization using EF + LORIF (28 cases), MIPPO (28 cases), or IMN (28 cases). The 3 groups were comparable with respect to patient demographics. Data were collected on operative time and radiation time, union time, complications, time of recovery to work, secondary operations, and measured joint function using the American Orthopaedic Foot and Ankle Society (AOFAS) score. There was no significant difference in time to union, incidence of union status, time of recovery to work, and AOFAS scores among the 3 groups (P>.05). Mean operative time and radiation time in the MIPPO group were longer than those in the IMN or EF + LORIF groups (Pknee pain occurred frequently after IMN (32.1%), and irritation symptoms were encountered more frequently after MIPPO (46.4%). Although EF + LORIF was associated with fewer secondary procedures vs MIPPO or IMN, it was related with more pin-tract infections (14.3%). Findings indicated that EF + LORIF, MIPPO, and IMN all achieved similar good functional results. However, EF + LORIF had some advantages over MIPPO and IMN in reducing operative and radiation times, postoperative complications, and reoperation rate. [Orthopedics. 2016; 39(4):e627-e633.]. Copyright 2016, SLACK Incorporated.

  8. DIAGNOSTICS AND TREATMENT OF DISTAL RADIOULNAR JOINT INJURIES

    Directory of Open Access Journals (Sweden)

    A. V. Skoroglyadov

    2010-01-01

    Full Text Available We present the experience of treatment of 169 patients with distal radioulnar joint injuries, operated in specialized hand surgery department of the Clinic of traumatology and orthopedics of Russian State Medical University on the base of Moscow city clinical hospital № 4. We have carried out the following operations: closed osteoclasia of the distal epimetaphys fractures, osteotomy of the radius with the external fixator application in 97 (57,4% patients, percutaneous 2 Kirschner wires fixation of the ulna head to the radius after reposition of dislocation - 38 (22,5% patients, lavsanoplasty of DRUJ ligaments - 12 (7,1%, fixation of the ulna head to the radius by pin - 7 (4,1%, open reposition of dislocation of the ulna head and K-wire fixation - 8 (4,8%, osteotomy of synostosis of forearm bones, W. Darrach and Sauve-Kapandji operations - 7 (4,1%. Complications were observed in 13 (7,7% cases. Postponed results (1 year after operation were studied in 110 patients. We got good results in 95 (86,4% cases, satisfactory - in 12 (10,9% cases, unsatisfactory - in 3 (2,7% cases.

  9. Complicated distal femoral epiphyseolysis treated by Ilizarov method: Case report

    Directory of Open Access Journals (Sweden)

    Jovanović Vesna

    2010-01-01

    Full Text Available Introduction Injuries of the distal femur are rare in children; however, they are frequently associated with complications. They are almost always physeal, most frequently Salter-Harris type II epiphyseolysis. The treatment of such injuries is similar in all physeal injuries. It is intended to provide growth plate recovery by gentle reduction and stable fixation thus preventing secondary complications, and also to provide decompression of the segment to solve the compartment syndrome and recover the neurovascular structures. Case Outline A seven-year old boy presented with a right knee injury while sleigh riding. He was admitted three weeks following the injury with distal femoral epiphysiolysis associated with peroneal palsy. A day after admission to our Institute the reduction was performed using the Ilizarov device. Physical therapy was started immediately after surgery, as well as walking with weight bearing on the operated leg. Five months after surgery the patient was anatomically and functionally recovered. Conclusion The presented method is recommended in the treatment of such injuries because of several reasons; reposition is simple and complete, there is no need to open the fracture site, fixation is stable, the growth plate is preserved, there is no need for additional external immobilisation, and physical therapy involving walking with weight bearing on the operated leg may be started immediately after surgery. .

  10. Distraction lengthening of the proximal phalanx in distal thumb amputations.

    Science.gov (United States)

    Cansü, Eren; Ünal, Mehmet Bekir; Parmaksızoğlu, Fatih; Gürcan, Serkan

    2015-01-01

    Thumb amputation is a major cause of hand dysfunction, and the treatment for distal thumb amputations remains controversial. Although finger reconstruction methods using distraction lengthening are known to restore finger length and function, we found no reports in the literature regarding phalangeal lengthening in thumb amputations. We aimed to evaluate proximal phalangeal lengthening in thumb amputations at or near the interphalangeal (IP) joint. We retrospectively evaluated patients who had undergone distraction lengthening of the proximal phalanx of the thumb. All patients underwent osteotomy, either during the initial procedure or as a second-stage procedure. Distraction began 10 days after osteotomy with the use of an external fixator that remained in place until ossification of the gap occurred without bone grafting. Patients were evaluated using the QuickDASH score. Fourteen patients with a mean age of 27 years and a mean follow-up period of 7 years were enrolled. The mean phalangeal lengthening achieved was 20 mm. Ossification occurred at all distraction sites, and the fixators were maintained for a mean of 85 days. The mean healing index was 42.5 days/cm. All 14 patients achieved the desired amount of phalangeal lengthening without major complications such as nonunion, premature union, or gross infection. For reconstruction in cases of distal thumb amputations, distraction lengthening of the proximal phalanx can be used to improve absolute length, web space, and grip distance. The technique is safe and effective, improves functionality/cosmesis, and offers a low complication risk.

  11. Intramedullary Venous Drainage System for Distal Fingertip Replantations.

    Science.gov (United States)

    Purisa, Husrev; Ozturk, Muhammed Besir; Kabakas, Fatih; Mersa, Berkan; Ozcelik, Ismail Bulent; Sezer, Ilker

    2017-08-01

    The number of venous anastomoses performed during fingertip replantation is one of the most important factors affecting the success of replantation. However, because vessel diameters decrease in the zone 1 level, vessel anastomoses, especially vein anastomoses, are technically difficult and, thus, cannot be performed in most cases. Alternative venous drainage methods are crucial when any reliable vein repair is not possible. In the literature, so many artery-only replantation techniques have been defined, such as arteriovenous anastomoses, forming an arteriovenous or venocutaneous fistula, manual milking and massage, puncturing, and external bleeding via a fishmouth incision and using a medical leech. It has been shown that, in distal fingertip replantations, the medullary cavity may also be a good way for venous return. In this study, we introduce an alternative intramedullary venous drainage system we developed to facilitate venous drainage in artery-only fingertip replantations. The results of 24 fingertip replantations distal to the nail fold by using this system are presented with a literature review.

  12. Radiographic evaluation for AVN following distal metatarsal Stoffella bunion osteotomy.

    Science.gov (United States)

    Klein, Christian; Zembsch, Alexander; Dorn, Ulrich

    2009-01-01

    Avascular necrosis of the metatarsal head, delayed bone healing and nonunion are complications that may occur after distal first metatarsal osteotomies. Intraoperative damage to the extraosseous blood supply, the location of the osteotomy and postoperative vasospasm have been cited as possible causes of such changes. We evaluated Stoffella's subcapital osteotomies which were performed at our department for the correction of moderate to severe hallux valgus deformities. Standardized radiographs of 300 feet, taken 6weeks, 3 months, and 6 months postoperatively and at the final followup were examined with regard to postoperative AVN or signs of delayed bone healing. Of 228 patients, 202 were women and 26 were men. The patients' mean age was 49 years, and the mean followup was 12 months. In 278 cases the radiographs revealed an unremarkable first metatarsal head. Seventeen cases showed diffuse or localized osteopenia or small cysts in the subchondral bone. These changes fully resolved on subsequent radiographs. The X-rays of two patients revealed progressive narrowing of the joint space, irregular contours on the surface of the joint and an abnormal bone structure. The patients subsequently developed a characteristic picture of avascular necrosis, in one case combined with nonunion. Three patients had delayed bone healing, but ultimately healed successfully. Ischemic changes in bone are known to occur after distal first metatarsal osteotomies. There is a very low incidence of postoperative perfusion problems after Stoffella;s technique, even with lateral soft tissue release.

  13. Simplified design of filter circuits

    CERN Document Server

    Lenk, John

    1999-01-01

    Simplified Design of Filter Circuits, the eighth book in this popular series, is a step-by-step guide to designing filters using off-the-shelf ICs. The book starts with the basic operating principles of filters and common applications, then moves on to describe how to design circuits by using and modifying chips available on the market today. Lenk's emphasis is on practical, simplified approaches to solving design problems.Contains practical designs using off-the-shelf ICsStraightforward, no-nonsense approachHighly illustrated with manufacturer's data sheets

  14. High flow ceramic pot filters

    OpenAIRE

    van Halem, D.; van der Laan, H.; Soppe, A. I.A.; Heijman, S.G.J.

    2017-01-01

    Ceramic pot filters are considered safe, robust and appropriate technologies, but there is a general consensus that water revenues are limited due to clogging of the ceramic element. The objective of this study was to investigate the potential of high flow ceramic pot filters to produce more water without sacrificing their microbial removal efficacy. High flow pot filters, produced by increasing the rice husk content, had a higher initial flow rate (6–19 L h−1), but initial LRVs for E. coli o...

  15. Face Recognition using Gabor Filters

    Directory of Open Access Journals (Sweden)

    Sajjad MOHSIN

    2011-01-01

    Full Text Available An Elastic Bunch Graph Map (EBGM algorithm is being proposed in this research paper that successfully implements face recognition using Gabor filters. The proposed system applies 40 different Gabor filters on an image. As aresult of which 40 images with different angles and orientation are received. Next, maximum intensity points in each filtered image are calculated and mark them as Fiducial points. The system reduces these points in accordance to distance between them. The next step is calculating the distances between the reduced points using distance formula. At last, the distances are compared with database. If match occurs, it means that the image is recognized.

  16. DO PROXIMAL AND DISTAL GASTRIC TUMOURS BEHAVE DIFFERENTLY?

    Science.gov (United States)

    Costa, Laurence Bedin da; Toneto, Marcelo Garcia; Moreira, Luis Fernando

    2016-01-01

    Although the incidence of gastric (adenocarcinoma) cancer has been decreasing over time, it is still one of the most common malignancies worldwide, and proximal tumours tend to have a worse prognosis. To compare surgical outcomes and prognosis between proximal - excluding tumours of the cardia - and distal gastric cancer. Out of 293 cases reviewed - 209 with distal and 69 with proximal gastric cancer - were compared for clinical and pathological features, stage, surgical outcome, mortality and survival. Statistically, there was no significant difference between patients in both groups regarding mortality (p=0.661), adjuvant chemotherapy (p 0.661), and radiation (p=1.000). However, there was significant difference in the degree of lymph node dissection employed (p=0.002) and the number of positive lymph nodes resected (p=0.038) between the two groups. The odds of death at five years for patients who had a D0 dissection was three times greater (odds ratio 2.78; (95%CI 1.33-5.82) than that for patients who had a D2 dissection, while for patients who had a D1 dissection the odds ratio was only 1.41 (95%CI 0.71-2.83) compared to D2-dissected patients. Although no significant differences were found between proximal and distal gastric cancer, the increased risk of death in D0- and D1-dissected patients clearly suggests an important role of radical D2 lymph node dissection in survival. Embora a incidência do câncer gástrico esteja diminuindo nas últimas décadas, ele ainda aparece como uma das neoplasias malignas mais comuns, e tumores proximais tendem a ter pior prognóstico. Comparar os resultados cirúrgicos e o prognóstico entre o câncer gástrico proximal, excluindo os tumores da cárdia e junção esofagogástrica, e o distal. De 293 casos revistos - 209 distais e 69 proximais - foram comparados quanto aos achados clínicos e patológicos, estágio, resultados cirúrgicos, mortalidade e sobrevida. Estatisticamente não houve diferença entre pacientes em ambos

  17. Broadband notch filter design for millimeter-wave plasma diagnostics

    DEFF Research Database (Denmark)

    Furtula, Vedran; Michelsen, Poul; Leipold, Frank

    2010-01-01

    Notch filters are integrated in plasma diagnostic systems to protect millimeter-wave receivers from intensive stray radiation. Here we present a design of a notch filter with a center frequency of 140 GHz, a rejection bandwidth of ∼ 900 MHz, and a typical insertion loss below 2 dB in the passband...... of ±9 GHz. The design is based on a fundamental rectangular waveguide with eight cylindrical cavities coupled by T-junction apertures formed as thin slits. Parameters that affect the notch performance such as physical lengths and conductor materials are discussed. The excited resonance mode...

  18. Remotely operated top loading filter housing

    International Nuclear Information System (INIS)

    Ross, M.J.; Carter, J.A.

    1989-01-01

    A high-efficiency particulate air (HEPA) filter system was developed for the Fuel Processing Facility at the Idaho Chemical Processing Plant. The system utilizes commercially available HEPA filters and allows in-cell filters to be maintained using operator-controlled remote handling equipment. The remote handling tasks include transport of filters before and after replacement, removal and replacement of the filter from the housing, and filter containment

  19. Concrete ensemble Kalman filters with rigorous catastrophic filter divergence.

    Science.gov (United States)

    Kelly, David; Majda, Andrew J; Tong, Xin T

    2015-08-25

    The ensemble Kalman filter and ensemble square root filters are data assimilation methods used to combine high-dimensional, nonlinear dynamical models with observed data. Ensemble methods are indispensable tools in science and engineering and have enjoyed great success in geophysical sciences, because they allow for computationally cheap low-ensemble-state approximation for extremely high-dimensional turbulent forecast models. From a theoretical perspective, the dynamical properties of these methods are poorly understood. One of the central mysteries is the numerical phenomenon known as catastrophic filter divergence, whereby ensemble-state estimates explode to machine infinity, despite the true state remaining in a bounded region. In this article we provide a breakthrough insight into the phenomenon, by introducing a simple and natural forecast model that transparently exhibits catastrophic filter divergence under all ensemble methods and a large set of initializations. For this model, catastrophic filter divergence is not an artifact of numerical instability, but rather a true dynamical property of the filter. The divergence is not only validated numerically but also proven rigorously. The model cleanly illustrates mechanisms that give rise to catastrophic divergence and confirms intuitive accounts of the phenomena given in past literature.

  20. Gravimetric Measurements of Filtering Facepiece Respirators Challenged With Diesel Exhaust.

    Science.gov (United States)

    Satish, Swathi; Swanson, Jacob J; Xiao, Kai; Viner, Andrew S; Kittelson, David B; Pui, David Y H

    2017-07-01

    Elevated concentrations of diesel exhaust have been linked to adverse health effects. Filtering facepiece respirators (FFRs) are widely used as a form of respiratory protection against diesel particulate matter (DPM) in occupational settings. Previous results (Penconek A, Drążyk P, Moskal A. (2013) Penetration of diesel exhaust particles through commercially available dust half masks. Ann Occup Hyg; 57: 360-73.) have suggested that common FFRs are less efficient than would be expected for this purpose based on their certification approvals. The objective of this study was to measure the penetration of DPM through NIOSH-certified R95 and P95 electret respirators to verify this result. Gravimetric-based penetration measurements conducted using polytetrafluoroethylene (PTFE) and polypropylene (PP) filters were compared with penetration measurements made with a Scanning Mobility Particle Sizer (SMPS, TSI Inc.), which measures the particle size distribution. Gravimetric measurements using PP filters were variable compared to SMPS measurements and biased high due to adsorption of gas phase organic material. Relatively inert PTFE filters adsorbed less gas phase organic material resulting in measurements that were more accurate. To attempt to correct for artifacts associated with adsorption of gas phase organic material, primary and secondary filters were used in series upstream and downstream of the FFR. Correcting for adsorption by subtracting the secondary mass from the primary mass improved the result for both PTFE and PP filters but this correction is subject to 'equilibrium' conditions that depend on sampling time and the concentration of particles and gas phase hydrocarbons. Overall, the results demonstrate that the use of filters to determine filtration efficiency of FFRs challenged with diesel exhaust produces erroneous results due to the presence of gas phase hydrocarbons in diesel exhaust and the tendency of filters to adsorb organic material. Published by

  1. Renal denervation beyond the bifurcation: The effect of distal ablation placement on safety and blood pressure.

    Science.gov (United States)

    Beeftink, Martine M A; Spiering, Wilko; De Jong, Mark R; Doevendans, Pieter A; Blankestijn, Peter J; Elvan, Arif; Heeg, Jan-Evert; Bots, Michiel L; Voskuil, Michiel

    2017-04-01

    Renal denervation may be more effective if performed distal in the renal artery because of smaller distances between the lumen and perivascular nerves. The authors reviewed the angiographic results of 97 patients and compared blood pressure reduction in relation to the location of the denervation. No significant differences in blood pressure reduction or complications were found between patient groups divided according to their spatial distribution of the ablations (proximal to the bifurcation in both arteries, distal to the bifurcation in one artery and distal in the other artery, or distal to the bifurcation in both arteries), but systolic ambulatory blood pressure reduction was significantly related to the number of distal ablations. No differences in adverse events were observed. In conclusion, we found no reason to believe that renal denervation distal to the bifurcation poses additional risks over the currently advised approach of proximal denervation, but improved efficacy remains to be conclusively established. ©2017 Wiley Periodicals, Inc.

  2. Regenerable Carbon Filter, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A Regenerable Carbon Filter (RCF) is proposed for the removal of carbonaceous particulate matter produced in Environmental Control and Life Support (ECLS) processes....

  3. Fremont Tree-Well Filter

    Science.gov (United States)

    Information about the SFBWQP Fremont Tree-Well Filter Spine project, part of an EPA competitive grant program to improve SF Bay water quality focused on restoring impaired waters and enhancing aquatic resources.

  4. Buffers and vegetative filter strips

    Science.gov (United States)

    Matthew J. Helmers; Thomas M. Isenhart; Michael G. Dosskey; Seth M. Dabney

    2008-01-01

    This chapter describes the use of buffers and vegetative filter strips relative to water quality. In particular, we primarily discuss the herbaceous components of the following NRCS Conservation Practice Standards.

  5. Ion trajectories quadrupole mass filters

    International Nuclear Information System (INIS)

    Ursu, D.; Lupsa, N.; Muntean, F.

    1994-01-01

    The present paper aims at bringing some contributions to the understanding of ion motion in quadrupole mass filters. The theoretical treatment of quadrupole mass filter is intended to be a concise derivation of the important physical relationships using Mathieu functions. A simple iterative method of numerical computation has been used to simulate ion trajectories in an ideal quadrupole field. Finally, some examples of calculation are presented with the aid of computer graphics. (Author) 14 Figs., 1 Tab., 20 Refs

  6. Filter indexing for spectrophotometer system

    International Nuclear Information System (INIS)

    Chamran, M.M.; Scott, L.B.; Williams, P.B.

    1982-01-01

    A spectrophotometer system has an optical system for transmitting a beam from a source at select wavelengths onto a detector. A plurality of filters are positioned in a tray. A stepper mechanism indexes the tray along a path. A microcomputer controls the stepper mechanism and the optical system. The wavelength is successively changed over a range, the tray is indexed to move a select filter into the beam at a predetermined wavelength and the changing is discontinued during indexing

  7. New iodine filter pack design

    International Nuclear Information System (INIS)

    Blackbee, B.A.

    1977-10-01

    To enable Naval Emergency Monitoring Teams to fulfil their role in the field it was necessary to locate or design a replacement filter pack for the collection of radioactive iodine air samples. Collaboration with the Berkeley Laboratories of the Central Electricity Generating Board provided the necessary starting point for a suitable type of package. Further development by NGTE (West Drayton) yielded the improved filter pack which is the subject of this memorandum. (author)

  8. Stochastic processes and filtering theory

    CERN Document Server

    Jazwinski, Andrew H

    1970-01-01

    This unified treatment of linear and nonlinear filtering theory presents material previously available only in journals, and in terms accessible to engineering students. Its sole prerequisites are advanced calculus, the theory of ordinary differential equations, and matrix analysis. Although theory is emphasized, the text discusses numerous practical applications as well.Taking the state-space approach to filtering, this text models dynamical systems by finite-dimensional Markov processes, outputs of stochastic difference, and differential equations. Starting with background material on probab

  9. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients

    OpenAIRE

    Gupta, Rakesh K.; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2009-01-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-...

  10. Intersphincteric Resection and Coloanal Anastomosis in Treatment of Distal Rectal Cancer

    OpenAIRE

    Cipe, Gokhan; Muslumanoglu, Mahmut; Yardimci, Erkan; Memmi, Naim; Aysan, Erhan

    2012-01-01

    In the treatment of distal rectal cancer, abdominoperineal resection is traditionally performed. However, the recognition of shorter safe distal resection line, intersphincteric resection technique has given a chance of sphincter-saving surgery for patients with distal rectal cancer during last two decades and still is being performed as an alternative choice of abdominoperineal resection. The first aim of this study is to assess the morbidity, mortality, oncological, and functional outcomes ...

  11. Classification of Distal Fingertip Amputation Based on the Arterial System for Replantation

    OpenAIRE

    Park, Hyun Chul; Bahar-Moni, Ahmed Suparno; Cho, Sang Hyun; Kim, Sang Soo; Park, Hyun Sik; Ahn, Sang Cheon

    2012-01-01

    During replantation of distal fingertip amputation, identification of the artery is the most important but time consuming procedure. Depending on the damaged arterial structure, we classified distal fingertip amputations into 4 zones, on the basis of three dimensional concept. Zone 1 injury was defined as damage to the proximal central pulp artery; zone 2 injury, damage to the branch of the central pulp artery; zone 3 injury, damage to the distal central pulp artery; and zone 4 injury, no inj...

  12. Reliability of radiographic measurements for acute distal radius fractures

    International Nuclear Information System (INIS)

    Watson, Narelle J.; Asadollahi, Saeed; Parrish, Frank; Ridgway, Jacqueline; Tran, Phong; Keating, Jennifer L.

    2016-01-01

    The management of distal radial fractures is guided by the interpretation of radiographic findings. The aim of this investigation was to determine the intra- and inter-observer reliability of eight traditionally reported anatomic radiographic parameters in adults with an acute distal radius fracture. Five observers participated. All were routinely involved in making treatment decisions based on distal radius fracture radiographs. Observers performed independent repeated measurements on 30 radiographs for eight anatomical parameters: dorsal shift (mm), intra-articular gap (mm), intra-articular step (mm), palmar tilt (degrees), radial angle (degrees), radial height (mm), radial shift (mm), ulnar variance (mm). Intraclass correlation coefficients (ICCs) and the magnitude of retest errors were calculated. Measurement reliability was summarised as high (ICC > 0.80), moderate (0.60–0.80) or low (<0.60). Intra-observer reliability was high for dorsal shift and palmar tilt; moderate for radial angle, radial height, ulnar variance and radial shift; and low for intra-articular gap and step. Inter-observer reliability was high for palmar tilt; moderate for dorsal shift, ulnar variance, radial angle and radial height; and low for radial shift, intra-articular gap and step. Error magnitude (95 % confidence interval) was within 1–2 mm for intra-articular gap and step, 2–4 mm for ulnar variance, 4–6 mm for radial shift, dorsal shift and radial height, and 6–8° for radial angle and palmar tilt. Based on previous reports of critical values for palmar tilt, ulnar variance and radial angle, error margins appear small enough for measurements to be useful in guiding treatment decisions. Our findings indicate that clinicians cannot reliably measure values ≤1 mm for intra-articular gap and step when interpreting radiographic parameters using the standardised methods investigated in this study. As a guide for treatment selection, palmar tilt, ulnar variance and radial angle

  13. A quantum extended Kalman filter

    International Nuclear Information System (INIS)

    Emzir, Muhammad F; Woolley, Matthew J; Petersen, Ian R

    2017-01-01

    In quantum physics, a stochastic master equation (SME) estimates the state (density operator) of a quantum system in the Schrödinger picture based on a record of measurements made on the system. In the Heisenberg picture, the SME is a quantum filter. For a linear quantum system subject to linear measurements and Gaussian noise, the dynamics may be described by quantum stochastic differential equations (QSDEs), also known as quantum Langevin equations, and the quantum filter reduces to a so-called quantum Kalman filter. In this article, we introduce a quantum extended Kalman filter (quantum EKF), which applies a commutative approximation and a time-varying linearization to systems of nonlinear QSDEs. We will show that there are conditions under which a filter similar to a classical EKF can be implemented for quantum systems. The boundedness of estimation errors and the filtering problem with ‘state-dependent’ covariances for process and measurement noises are also discussed. We demonstrate the effectiveness of the quantum EKF by applying it to systems that involve multiple modes, nonlinear Hamiltonians, and simultaneous jump-diffusive measurements. (paper)

  14. A quantum extended Kalman filter

    Science.gov (United States)

    Emzir, Muhammad F.; Woolley, Matthew J.; Petersen, Ian R.

    2017-06-01

    In quantum physics, a stochastic master equation (SME) estimates the state (density operator) of a quantum system in the Schrödinger picture based on a record of measurements made on the system. In the Heisenberg picture, the SME is a quantum filter. For a linear quantum system subject to linear measurements and Gaussian noise, the dynamics may be described by quantum stochastic differential equations (QSDEs), also known as quantum Langevin equations, and the quantum filter reduces to a so-called quantum Kalman filter. In this article, we introduce a quantum extended Kalman filter (quantum EKF), which applies a commutative approximation and a time-varying linearization to systems of nonlinear QSDEs. We will show that there are conditions under which a filter similar to a classical EKF can be implemented for quantum systems. The boundedness of estimation errors and the filtering problem with ‘state-dependent’ covariances for process and measurement noises are also discussed. We demonstrate the effectiveness of the quantum EKF by applying it to systems that involve multiple modes, nonlinear Hamiltonians, and simultaneous jump-diffusive measurements.

  15. Whistleblower Protection

    Science.gov (United States)

    The Whistleblower Protection Enhancement Act of 2012 (WPA) and the Whistleblower Protection Act of 1989 Enhanced by the Act of 2012 provides protection rights for Federal employees against retaliation for whistleblowing activities.

  16. Fractures of the bilateral distal radius and scaphoid: a case report

    Directory of Open Access Journals (Sweden)

    Ozkan Korhan

    2008-03-01

    Full Text Available Abstract Introduction Bilateral fractures of the distal radius and scaphoid are extremely rare injuries. Case presentation A patient with bilateral comminuted, displaced distal fractures of the radius and bilateral fractures of the scaphoid was treated via internal fixation of the scaphoid fractures with Herbert screws and internal fixation of the distal radius fractures with locked volar plating. Conclusion Rigid internal fixation of distal radius and scaphoid fractures is mandatory to start early active rehabilitation of the wrist without the need for wrist immobilization with a plaster or external skeletal fixation.

  17. Experience with three percutaneous vena cava filters

    International Nuclear Information System (INIS)

    McCowan, T.C.; Ferris, E.J.; Harshfield, D.L.; Hassell, D.R.; Baker, M.L.

    1987-01-01

    Twenty-one Kimray-Greenfield, 33 bird's nest, and 19 Amplatz vena cava filters were placed percutaneously. The Kimray-Greenfield filter was the most difficult to insert. The major problem was the insertion site, which required venipuncture with a 24-F catheter. Minor hemorrhage was frequent, and femoral vein thrombosis occurred in four patients. No migration, caval thrombosis, or pulmonary emboli were seen after Kimray-Greenfield filter placement. The bird's nest filter was relatively easy to insert, although in two cases the filter prongs could not be adequately seated in the wall of the inferior vena cava. Three patients with bird's nest filters had thrombosis below the filter, and three filters migrated to the heart. One migrated filter could not be removed. One patient had multiple small pulmonary emboli at autopsy. No other pulmonary emboli after filter placement were noted. The Amplatz filter was the easiest of the three filters to insert. Only one patient with an Amplatz filter had thrombosis of the vena cava below the filter. No filter migrations were documented, and no recurrent pulmonary emboli were found on clinical or radiologic follow-up. The Amplatz vena cava filter is easier to place than percutaneous Kimray-Greenfield or bird's nest filters, has a low complication rate, and has proven to be clinically effective in preventing pulmonary emboli

  18. Study of loading/air back-pulse cleaning cycles on the performance of ceramic membrane filters

    International Nuclear Information System (INIS)

    Waggoner, Charles; Alderman, Steven; Parsons, Michael; Hogoncamp, Kristina; Alderman, Steven

    2007-01-01

    Available in abstract form only. Full text of publication follows: The most commonly identified threats to conventional glass fiber HEPA filter performance are moisture and rapid blinding of filters by smoke. Regenerable filter media composed of ceramics or sintered metal can be utilized as pre-filters to protect the more vulnerable glass fiber HEPA filters in the event of upset conditions. Additionally, used in a pre-filtering application, the use of these regenerable filters can potentially extend the lifetime of conventional units. A series of tests have been conducted using CeraMem ceramic membrane filters in an effort to evaluate their performance after repeated loading and air back pulse cleaning. This was done in an effort to access filter performance after repeated loading/cleaning cycles. The filters were loaded using a solid potassium chloride aerosol challenge. The filters were evaluated for pressure drop and filtering efficiency changes from one cleaning cycle to the next. Additionally, the particle size distribution of the aerosol penetrating the filters was measured. (authors)

  19. Sensory pollution from bag-type fiberglass ventilation filters: Conventional filter compared with filters containing various amounts of activated carbon

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Fadeyi, M.O.; Clausen, Geo

    2009-01-01

    filter and three modifications of a bag-type fiberglass combination filter: the "Heavy" corresponded to a commercially available filter containing 400 g of carbon per square meter of filter area, the "Medium" contained half as much carbon (200 g/m(2)), and the "Light" contained a quarter as much carbon...

  20. Sarcoidosis: radiographic manifestations in the nails and distal phalanges

    Energy Technology Data Exchange (ETDEWEB)

    Albers, Brittany K.; Garner, Hillary W. [Mayo Clinic, Department of Radiology, Jacksonville, FL (United States); Sluzevich, Jason C. [Mayo Clinic, Department of Dermatology, Jacksonville, FL (United States)

    2016-05-15

    Sarcoidosis is a granulomatous disease which can affect multiple organ systems. Clinical and radiologic manifestations depend on the organ system involved and the chronicity of disease. Nail involvement in sarcoidosis is rare, but is clinically relevant as it indicates chronic systemic disease. Nail abnormalities can be identified radiographically, and when seen in patients with known or suspected sarcoidosis, should prompt careful evaluation of the underlying bone for osseous involvement. We describe a case of sarcoidosis with radiographic findings in the nails and distal phalangeal tufts, which were indicative of nail and osseous sarcoid involvement and strongly supported the presence of chronic systemic disease. Although the nail findings resolved clinically and on radiographs after treatment, the osseous findings showed only minimal improvement. To our knowledge, the radiographic findings of nail sarcoidosis have not been previously addressed in the literature. (orig.)