WorldWideScience

Sample records for distal protection devices

  1. Distal protection filter device efficacy with carotid artery stenting: comparison between a distal protection filter and a distal protection balloon.

    Science.gov (United States)

    Iko, Minoru; Tsutsumi, Masanori; Aikawa, Hiroshi; Matsumoto, Yoshihisa; Go, Yoshinori; Nii, Kouhei; Abe, Gorou; Ye, Iwae; Nomoto, Yasuyuki; Kazekawa, Kiyoshi

    2013-01-01

    This retrospective study aimed to compare the effectiveness of the embolization prevention mechanism of two types of embolic protection device (EPD)-a distal protection balloon (DPB) and a distal protection filter (DPF). Subjects were 164 patients scheduled to undergo carotid artery stenting: a DPB was used in 82 cases (DPB group) from April 2007 until June 2010, and a DPF was used in 82 cases (DPF group) from July 2010 to July 2011. Rates of positive findings on postoperative diffusion-weighted imaging (DWI) and stroke incidence were compared. Positive postoperative DWI results were found in 34 cases in the DPB group (41.4 %), but in only 22 cases in the DPF group (26.8 %), and there was only a small significant difference within the DPF group. In the DPB group, there was one case of transient ischemic attack (TIA) (1.2 %) and four cases of brain infarction (2 minor strokes, 2 major strokes; 4.9 %), compared to the DFP group with one case of TIA (1.2 %) and no cases of minor or major strokes. In this study, significantly lower rates of occurrence of DWI ischemic lesions and intraoperative embolization were associated with use of the DPF compared to the DPB.

  2. Analysis of emboli during carotid stenting with distal protection device.

    Science.gov (United States)

    Chen, Chin-I; Iguchi, Yasuyuki; Garami, Zsolt; Malkoff, Marc D; Smalling, Richard W; Campbell, Morgan S; Alexandrov, Andrei V

    2006-01-01

    The newly developed multi-frequency transcranial Doppler (TCD) is able to differentiate gaseous from solid emboli. Our goal was to apply this technology to initially characterize emboli detected during carotid stenting with distal protection. Patients undergoing carotid angiography and stenting were monitored with 2-2.5 MHz TCD (Embo-Dop, DWL) over the middle cerebral artery unilateral to stent deployment. Sonographers insured optimal signal recordings during the procedures. Automated emboli detection and classification software (MultiXLab version 2.0) was applied for offline count and analysis. Monitoring using the Filter Wire EX (Boston Scientific) and ACCUNET system (Guidant Corporation) was performed. A total of 9,649 embolic signals were detected during 11 angiographic and 10 stenting procedures. An observer confirmed the signals using the International Consensus definition. Automated software classified these events into 5,900 gaseous and 3,749 solid emboli. During contrast injections without the protection device, 1,013 emboli were detected with 28% of these being solid. With deployment of the distal protection device, 8,636 emboli were found with 40% being solid (p protection device, 7,395 emboli with 42% solids were detected (p protection device still deployed, yielded 1,241 emboli with 31% solids (NS). Only 1 patient developed transient hemiparesthesia during ballooning that reduced the flow velocity to zero for 14 s. Neither gaseous nor solid emboli resulted in a mean flow velocity decrease or clinical symptoms. Microembolization frequently occurs during stenting even with deployment of the distal protection device. More solid emboli are seen during manipulations associated with lesion crossing. Although novel TCD methods yield a high frequency of embolic signals, further validation of this technique to determine the true nature, size, and number of emboli is needed.

  3. Efficiency and safety of percuSurge distal protection device in acute ...

    African Journals Online (AJOL)

    user

    2011-04-25

    Apr 25, 2011 ... myocardial infarction. The long-term effects of the distal protection device are still in controversy. The enhanced myocardial efficacy and recovery by aspiration of liberated debris (EMERALD) trial failed to show the effectiveness of the distal protection device in patients with AMI (Yamada and Topol, 2000).

  4. Retinal artery occlusion during carotid artery stenting with distal embolic protection device.

    Science.gov (United States)

    Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu

    2018-01-01

    Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.

  5. Transcranial Doppler monitoring during stenting of the carotid bifurcation: evaluation of two different distal protection devices in preventing embolization.

    Science.gov (United States)

    Rubartelli, Paolo; Brusa, Giulia; Arrigo, Alessandro; Abbadessa, Francesco; Giachero, Corinna; Vischi, Massimo; Ricca, Maria Maddalena; Ottonello, Gian Andrea

    2006-08-01

    To compare the efficacy of 2 emboli protection devices in preventing embolization during carotid artery stenting (CAS). The GuardWire distal occlusion system (n=19) and the distal FilterWire EX (n=12) were compared in 31 consecutive patients (24 men; mean age 71+/-10 years) monitored with transcranial Doppler for microembolic signals before, during, and after CAS. The choice of the protection device was based on availability and on the patency of the contralateral carotid artery. The baseline characteristics were similar in the patients treated under protection from either device. Placement and retrieval of the protection device, stenting, and postdilation were technically successful in all patients. Two patients suffered a transient ischemic attack shortly after the procedure; no other adverse cardiovascular events occurred at 30 days. Compared to the GuardWire, the use of the FilterWire was associated with more microembolic signals during stent deployment (77.4+/-33.5 versus 1.07+/-1.94, pprotection device (21.4+/-15.4 versus 10.9+/-8.3, p=0.051). Consequently, the total amount of microembolic signals during the procedure was higher when the filter device was employed (183.0+/-42.1 versus 31.7+/-12.0, p<0.0001). The distal occlusion device appears to be more effective than the filter in reducing distal embolization detected by transcranial Doppler monitoring.

  6. Distal protection in cardiovascular medicine: current status.

    Science.gov (United States)

    Ali, Onn Akbar; Bhindi, Ravinay; McMahon, Aisling C; Brieger, David; Kritharides, Leonard; Lowe, Harry C

    2006-08-01

    Iatrogenic and spontaneous downstream microembolization of atheromatous material is increasingly recognized as a source of cardiovascular morbidity and mortality. Devising ways of reducing this distal embolization using a variety of mechanical means--distal protection--is currently under intense and diverse investigation. This review therefore summarizes the present status of distal protection. It examines the problem of distal embolization, describes the available distal protection devices, reviews those areas of cardiovascular medicine where distal protection devices are being investigated, and discusses potential future developments.

  7. Combined application of distal and proximal embolic protection devices in endovascular stenting for severe carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Zhi-hua DU

    2011-09-01

    Full Text Available Objective To analyze and summarize methods and experiences of combined application of distal and proximal embolic protection devices(EPD in endovascular stenting for severe carotid artery stenosis.Methods Five patients with severe stenosis of the common carotid artery or with extracranial segment of the internal carotid artery diagnosed through digital subtraction angiography(DSA from March to July 2010 were involved in the present study.All patients received carotid angioplasty and stenting(CAS,with a combination of distal and proximal EPD via the percutaneous femoral artery approach.Results The operation failed in one patient,whereas technical success with no intraoperative complication was achieved in four patients.The symptoms disappeared or improved in the four cases that achieved technical success.The follow-up duration was one to three months,and no cerebral ischemia was found.Conclusion CAS with the combined application of distal and proximal EPD in some special cases of carotid artery stenosis may surmount the shortage of single EPD,reduce the risk of intraoperative embolization,decrease the time of intraoperative endovascular inflow occlusion,and reduce high-risk operations.CAS may be used as an individualized treatment strategy for patients with carotid artery stenosis.

  8. Distal Embolic Protection for Renal Arterial Interventions

    International Nuclear Information System (INIS)

    Dubel, Gregory J.; Murphy, Timothy P.

    2008-01-01

    Distal or embolic protection has intuitive appeal for its potential to prevent embolization of materials generated during interventional procedures. Distal protection devices (DPDs) have been most widely used in the coronary and carotid vascular beds, where they have demonstrated the ability to trap embolic materials and, in some cases, to reduce complications. Given the frequency of chronic kidney disease in patients with renal artery stenosis undergoing stent placement, it is reasonable to propose that these devices may play an important role in limiting distal embolization in the renal vasculature. Careful review of the literature reveals that atheroembolization does occur during renal arterial interventions, although it often goes undetected. Early experience with DPDs in the renal arteries in patients with suitable anatomy suggests retrieval of embolic materials in approximately 71% of cases and renal functional improvement/stabilization in 98% of cases. The combination of platelet inhibition and a DPD may provide even greater benefit. Given the critical importance of renal functional preservation, it follows that everything that can be done to prevent atheroembolism should be undertaken including the use of DPDs when anatomically feasible. The data available at this time support a beneficial role for these devices

  9. Cerebral Ischemia Detected with Diffusion-Weighted MR Imaging after Protected Carotid Artery Stenting: Comparison of Distal Balloon and Filter Device

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Suk Jung; Jeon, Pyoung [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Roh, Hong Gee [Konkuk University Hospital, Seoul (Korea, Republic of)] (and others)

    2007-08-15

    The aim of this study was to examine the incidence of ischemia during protected carotid artery stenting (CAS) as well as to compare the protective efficacy of the balloon and filter devices on diffusion-weighted MR imaging (DWI). Seventy-one consecutive protected CAS procedures in 70 patients with a severe (> 70%) or symptomatic moderate (> 50%) carotid artery stenosis were examined. A balloon device (PercuSurge GuardWire) and a filter device (FilterWire EX/EZ, Emboshield) was used in 33 cases (CAS-B group) and 38 cases (CAS-F group) to prevent distal embolization, respectively. All the patients underwent DWI within seven days before and after the procedures. The number of new cerebral ischemic lesions on the post-procedural DWI were counted and divided into ipsilateral and contralateral lesions according to the relationship with the stenting side. New cerebral ischemic lesions were detected in 13 (39.4%) out of the 33 CAS-Bs and in 15 (39.5%) out of the 38 CAS-Fs. The mean number of total, ipsilateral and contralateral new cerebral ischemic lesion was 2.39, 1.67 and 0.73 in the CAS-B group and 2.11, 1.32 and 0.79 in the CAS-F group, respectively. No statistical differences were found between the two groups (p = 0.96, 0.74 and 0.65, respectively). The embolic complications encountered included two retinal infarctions and one hemiparesis in the CAS-B group (9.09%), and one retinal infarction, one hemiparesis and one ataxia in the CAS-F group (7.89%). There was a similar incidence of embolic complications in the two groups (p 1.00). The type of distal protection device used such as a balloon and filter does not affect the incidence of cerebral embolization after protected CAS.

  10. Vertebral artery origin stent placement with distal protection: technical and clinical results.

    Science.gov (United States)

    Qureshi, A I; Kirmani, J F; Harris-Lane, P; Divani, A A; Ahmed, S; Ebrihimi, A; Al Kawi, A; Janjua, N

    2006-05-01

    To report the feasibility, safety, and 1-month results of performing stent placement for vertebral origin stenosis with the use of a distal protection device. Distal protection devices have been shown to reduce the number of cerebral emboli and subsequent ischemic events when used as adjuncts to percutaneous carotid intervention; however, one case of the use of a distal protection device for vertebral artery has been reported in the literature. We retrospectively determined rates of technical success and 1-month stroke or death associated with stent placement by using distal protection (Filter EX; Boston Scientific, Natick, Mass) in patients with symptomatic vertebral artery origin stenosis. Technical success was defined as successful deployment of distal protection device and stent at target lesion followed by successful retrieval of the device and a final residual stenosis of less than 30%. Other outcomes ascertained included any stroke, death, and semiquantitative assessment of particulate material retained by the filter device. The mean age of the 12 treated patients was 68 years (range, 52-88 years) and the group included 9 men and 3 women. The mean percentage of vertebral artery origin stenosis was 71 +/- 6%. Femoral and radial approaches were used in 9 and 3 cases, respectively. Technical success was achieved in 11 of the 12 patients in whom distal protection device placement was attempted. Postprocedure residual stenosis was 5 +/- 4%. Eight devices held macroscopically visible embolic debris (large and small amounts in 3 and 5 devices, respectively). No stroke or death was observed in the 1-month follow-up. The present study demonstrates the feasibility of performing stent placement for vertebral artery origin stenosis by using a distal protection device. Further studies are required to determine the effectiveness of this approach for vertebral artery origin atherosclerosis.

  11. Protection device for a thermonuclear device

    International Nuclear Information System (INIS)

    Kawashima, Shuichi.

    1986-01-01

    Purpose: To exactly detect the void coefficients of coolants even under high magnetic fields thereby detect the overheat of a thermonuclear device at an early stage. Constitution: The protecting device of this invention comprises a laser beam generation device, a laser beam detection device and an accident detection device. The laser generation device always generates laser beams, which are permeated through coolants and detected by the laser beam detection device, the optical amount of which is transmitted to the accident detection device. The accident detection device judges the excess or insufficiency of the detected optical amount with respect to the optical amount of the laser beams under the stationary state as a reference and issues an accident signal. Since only the optical cables that do not undergo the effect of the magnetic fields are exposed to high magnetic fields in the protection device of this invention, a high reliability can be maintained. (Kamimura, M.)

  12. Left ventricular contractile function after distal protection in primary percutaneous coronary intervention Results from the Drug Elution and Distal Protection in ST-Elevation Myocardial Infarction trial

    DEFF Research Database (Denmark)

    Kofoed, K F; Kelbæk, H; Thuesen, L

    2011-01-01

    Coronary intervention (PCI) may result in an increased infarct size. We evaluated the effect of distal protection during PCI for ST-segment elevation myocardial infarction (STEMI) on myocardial function.......Coronary intervention (PCI) may result in an increased infarct size. We evaluated the effect of distal protection during PCI for ST-segment elevation myocardial infarction (STEMI) on myocardial function....

  13. Subclinical ischemic events in patients undergoing carotid artery stent placement: comparison of proximal and distal protection techniques.

    Science.gov (United States)

    Aytac, Emrah; Gürkaş, Erdem; Akpinar, Cetin Kursad; Saleem, Muhammad A; Qureshi, Adnan I

    2017-10-01

    To determine the relative effectiveness of proximal and distal protection in prevention of cerebral ischemic events during carotid artery stent (CAS) placement using diffusion-weighted MRI (DW-MRI). We analyzed data from patients who had undergone DW-MRI before and within 24 hours of CAS for symptomatic internal carotid artery (ICA) stenosis (with last ischemic events within 3 months). The study was performed prospectively; patients were not randomized, and were treated either with a proximal balloon occlusion system (Mo.Ma; Invatec, Roncadelle, Italy) or filter-type distal protection device (Spider device; ev3, Plymouth, Minnesota, USA). Of the 45 patients (mean age±SD: 66.9±9.8 years; 73.3% were men) who underwent CAS, 19 had proximal protection and 26 distal protection. New ischemic lesions were detected in 26/45 patients on DW-MRI scans obtained within 24 hours after CAS. The proportion of patients with new lesions on DW-MRI at 24 hours was not different between the two groups (47.4% vs 65.4% for proximal and distal protection, respectively). The mean number of new ischemic lesions on post-CAS DW-MRI was non-significantly higher in patients who underwent CAS with distal protection (2.80±3.54 for proximal protection vs 4.96±5.11 for distal protection; p=0.12). The proportion of patients with new lesions >1 cm did not differ between the two groups (5.3% for proximal protection vs 11.5% for distal protection; p=0.62). There was no difference in the rates of ischemic stroke between patients who underwent CAS treatment using proximal and distal protection (5.3% vs 7.7%; p=1.000). We found a relatively high rate of new ischemic lesions in patients undergoing CAS with cerebral protection. There was no difference in the proportion of patients with new lesions between patients treated using distal protection and those treated using proximal protection. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a

  14. Reactor protecting device

    International Nuclear Information System (INIS)

    Ono, Hiroshi; Kasuga, Hajime; Kasuga, Hiroshi.

    1984-01-01

    Purpose: To reduce the recycling flowrate thereby decrease the neutron flux level before the reactor shutdown upon generation of abnormality such as increase in the neutron flux, by setting the safety level lower than the value for generating the reaction scram signal. Constitution: A netron flux safety level setter and an instruction signal generator are disposed between a neutron flux detector and a recycling flowrate control device. A neutron flux safety level lower than the level for generating a reactor scram signal and higher that the level for the ordinary operation is set and, if the detection level for the neutron flux in the reactor core arrives at the safety level, a neutron flux decreasing instruction signal is outputted from the instruction signal generator to the recycling flowrate control device to thereby decrease the recycling flowrate and decrease the neutron flux without reaching the reactor shutdown, whereby the thermal safety of the fuel rod can be maintained and the reactor operation performance can be improved. (Moriyama, K.)

  15. Radiation leaking protection device

    International Nuclear Information System (INIS)

    Sunami, Yoshio; Mitsumori, Kojiro

    1980-01-01

    Purpose: To prevent radioactivity from leaking outside of a reactor container by way of pipeways passing therethrough, by supplying pressurized fluid between each of a plurality of valves for separating the pipeways. Constitution: Pressurized fluid is supplied between each of a plurality of valves for separating pipeways. For instance, water in a purified water tank is pressurized by a pressure pump and the pressure of the pressurized water is controlled by a differential pressure detector, a pressure controller and a pressure control valve. In the case if a main steam pipe is ruptured outside of the reactor container or to be repaired, the separation valves are wholly closed and then the pressurizing device is actuated to supply pressurized water containing no radioactivity from the purified water tank to the position between the valves. The pressure in the pressurized water is controlled such that it is always higher by a predetermined level than the pressure in the reactor. This prevents the radioacitivity in the reactor core from leaking outside of the container passing through the valves, whereby radiation exposure in the working can be reduced and the circumferential contamination upon accident of pipeway rupture can be decreased. (Kawakami, Y.)

  16. Reactor protection device

    Energy Technology Data Exchange (ETDEWEB)

    Shida, T; Hirose, M

    1977-01-19

    Purpose: To prevent abrupt increase or decrease in the recycling flow rate by comparing output signals from controllers in each of the loops in the recycling flow rate control system to lock the positions of fluid coupling scooping pipes or flow control valves corresponding to the groups generating abnormal signals. Constitution: The recycling flow rate is controlled by the r.p.m. of a motor directly coupled with a recycling pump and the value of r.p.m. is in proportion to the generator frequency varied with the sliding operation of the fluid coupling in MG set. The sliding operation of the fluid coupling is adjusted by a scooping pipe driver. When the device is set to automatic operation, the output signal of the main controller is delivered to the recycling flow rate control system, the output signal of which is input to respective scooping pipe drivers. The loop output signals are supplied to an adder where the deviation signal between both of them are detected and the scooping pipe is locked if the set value is exceeded.

  17. Reactor protection device

    International Nuclear Information System (INIS)

    Shida, Toichi; Hirose, Masao.

    1977-01-01

    Purpose: To prevent abrupt increase or decrease in the recycling flow rate by comparing output signals from controllers in each of the loops in the recycling flow rate control system to thereby lock the positions of fluid coupling scooping pipes or flow control valves corresponding to the groups generating abnormal signals. Constitution: The recycling flow rate is controlled by r.p.m. of a motor directly coupled with a recycling pump and the value of r.p.m. is in proportion to the generator frequency varied with the sliding operation of the fluid coupling in MG set. The sliding operation of the fluid coupling is adjusted by a scooping pipe driver. When the device is set to automatic operation, the output signal of the main controller is delivered to the recycling flow rate control system, the output signal of which is input to respective scooping pipe drivers. The loop output signals are supplied to an adder where the deviation signal between both of them are detected and the scooping pipe is locked if the set value is exceeded. (Yoshino, M.)

  18. Randomized comparison of distal protection versus conventional treatment in primary percutaneous coronary intervention: the drug elution and distal protection in ST-elevation myocardial infarction (DEDICATION) trial

    DEFF Research Database (Denmark)

    Kelbaek, Henning; Terkelsen, Christian J; Helqvist, Steffen

    2008-01-01

    OBJECTIVES: The purpose of this study was to evaluate the use of distal protection during percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI) in native coronary vessels. BACKGROUND: Embolization of material from the infarct-related lesion during PCI may...

  19. Ex-vivo release of Pipeline Embolization Device polytetrafluoroethylene (PTFE) sleeves for improved distal landing zone accuracy in-vivo: A technical note.

    Science.gov (United States)

    Griessenauer, Christoph J; Gupta, Raghav; Moore, Justin; Thomas, Ajith J; Ogilvy, Christopher S

    2016-12-01

    Distal landing zone accuracy is critical in some intracranial aneurysms treated with the Pipeline Embolization Device (PED), and delayed opening of the distal end of the device can complicate the procedure. Here, we report a technical nuance that facilitates accurate placement of the distal end of the PED by ex-vivo, pre-implantation release of the PED Flex polytetrafluoroethylene (PTFE) sleeves. The PED Flex is partially pushed out of the introducer sheath ex-vivo, pre-implantation until the distal PED opens entirely and the PTFE sleeves are located distal to the device. Without inverting the PTFE sleeves, the PED is carefully pulled back into the introducer sheath placing the PTFE sleeves inside the device. The PED is loaded into the microcatheter and advanced toward the site of implantation. When the PED is initially deployed and pushed out of the microcatheter, it opens immediately and provides an anchor for the remainder of the deployment process. We present a video (supplementary material) that illustrates the technique along with an illustrative case. Ex-vivo, pre-implantation release of the PTFE sleeves is an option in aneurysm treatment where distal landing accuracy is critical. Even without the protection of the PTFE sleeves, our clinical observation shows that the PED can be advanced safely through the microcatheter in selected cases. © The Author(s) 2016.

  20. Evaluation of the Stryker S2 IM Nail Distal Targeting Device for reduction of radiation exposure: a case series study.

    Science.gov (United States)

    Anastopoulos, George; Ntagiopoulos, Panagiotis G; Chissas, Dionisios; Loupasis, George; Asimakopoulos, Antonios; Athanaselis, Eustratios; Megas, Panagiotis

    2008-10-01

    Distal locking is one challenging step during intramedullary nailing of femoral shaft fractures that can lead to an increase of radiation exposure. In the present study, the authors describe a technique for the distal locking of femoral nails, implementing a new targeting device in an attempt to reduce radiation exposure and operational time. Over a 2-year period, 127 consecutive cases of femoral shaft fractures were included in the study. All cases were treated with nailing of femoral shaft fractures with an unslotted reamed antegrade femoral nail and distal locking was performed with the use of a proximally mounted aiming device. Mean duration of the procedure was 63.5 18.1 min while the duration for distal locking was 6.6 +/- 2.6 min. In all successful cases, exposure from intraoperative fluoroscopy was 17.2 +/- 7.4 s for the whole operative procedure, and for distal locking was 2 shots, 1.35 s (range, 0.9-2.2 s) and 1.9 mGy (range, 1.1-2.9 mGy). Five cases (3.9%) were unsuccessful, but overall no intraoperative complications were encountered from the application of this technique. The ability of the device to correspond to the level of nail deformation and to properly identify the distal holes, reduced exposure to radiation compared to other published reports, and should be considered as a valuable tool for distal locking of femoral fractures.

  1. Nuclear reactor safety protection device

    International Nuclear Information System (INIS)

    Okido, Fumiyasu; Noguchi, Atomi; Matsumiya, Shoichi; Furusato, Ken-ichiro; Arita, Setsuo.

    1994-01-01

    The device of the present invention extremely reduces a probability of causing unnecessary scram of a nuclear reactor. That is, four control devices receive signals from each of four sensors and output four trip signals respectively in a quardruplicated control device. Each of the trip signals and each of trip signals via a delay circuit are inputted to a logical sum element. The output of the logical sum circuit is inputted to a decision of majority circuit. The decision of majority circuit controls a scram pilot valve which conducts scram of the reactor by way of a solenoid coils. With such procedures, even if surge noises of a short pulse width are mixed to the sensor signals and short trip signals are outputted, there is no worry that the scram pilot valve is actuated. Accordingly, factors of lowering nuclear plant operation efficiency due to erroneous reactor scram can be reduced. (I.S.)

  2. Gate protective device for SOS array

    Science.gov (United States)

    Meyer, J. E., Jr.; Scott, J. H.

    1972-01-01

    Protective gate device consisting of alternating heavily doped n(+) and p(+) diffusions eliminates breakdown voltages in silicon oxide on sapphire arrays caused by electrostatic discharge from person or equipment. Diffusions are easily produced during normal double epitaxial processing. Devices with nine layers had 27-volt breakdown.

  3. Protection for a thermonuclear device

    International Nuclear Information System (INIS)

    Shimada, Ryuichi; Sasatani, Shin-ichi.

    1983-01-01

    Purpose: To suppress an abnormal voltage due to potential changes by a characteristic impedance composed of a discharge gap, a resistance and a capacitor, as well as absorb the energy of the abnormal voltage by properly selecting the current capacity of the resistor. Constitution: An abnormal voltage generated in a current transformer coils is detected by an abnormal voltage detector and an output signal therefrom causes a high voltage generating device to generate a high voltage, whereby electric discharge is taken place across a discharge gap to absorb the energy of the abnormal voltage in a resistor and a capacitor. For the abnormal voltage from the plasmas, the voltage across the transformer coils can be suppressed to some extent by selecting the impedance for the current transformer coils and the impedance for the parallel circuit of the resistor and the capacitor to an appropriate ratio. While on the other hand, after throwing a switcher by the actuation of a switcher control device, the energy for the abnormal voltage can sufficiently be absorbed through the internal resistance of the transformer coils and the resistance for the entire current. (Yoshino, Y.)

  4. High energy overcurrent protective device

    Science.gov (United States)

    Praeg, Walter F.

    1982-01-01

    Electrical loads connected to capacitance elements in high voltage direct current systems are protected from damage by capacitance discharge overcurrents by connecting between the capacitance element and the load, a longitudinal inductor comprising a bifilar winding wound about a magnetic core, which forms an incomplete magnetic circuit. A diode is connected across a portion of the bifilar winding which conducts a unidirectional current only. Energy discharged from the capacitance element is stored in the inductor and then dissipated in an L-R circuit including the diode and the coil winding. Multiple high voltage circuits having capacitance elements may be connected to loads through bifilar windings all wound about the aforementioned magnetic core.

  5. Protective device for battery to protect against heavy discharge

    Energy Technology Data Exchange (ETDEWEB)

    1979-02-08

    The protective device according to the invention switches the equipment being supplied from the battery at a pre-determined discharge voltage by means of a switching device controlled by monitoring equipment. A semi-conductor element is used as the switching device. The current taken from the battery flows through the semi-conductor element to the equipment and to the monitoring device. When the discharge voltage is reached the semi-conductor element blocks. The semi-conductor switch can consist of transistors. The invention is explained by means of drawings and examples.

  6. Sheath rendezvous method: a novel distal protection technique during endovascular treatment of subclavian artery occlusions.

    Science.gov (United States)

    Haraguchi, Takuya; Urasawa, Kazushi; Nakama, Tatsuya; Nakagawa, Yuya; Tan, Michinao; Koshida, Ryoji; Sato, Katsuhiko

    2016-10-01

    To describe an innovative distal protection technique, "sheath rendezvous method", during endovascular treatment for subclavian arterial occlusions. 4.5F and 6F guiding sheath were inserted from left brachial and common femoral artery, respectively. 0.014″ guidewire retrogradely passed through occlusion and into antegrade sheath to establish a pull-through system. 3.0 mm balloon was used to expand occlusion and anchor to deliver retrograde sheath into antegrade one. Both sheaths locked by balloon dilatation crossed occlusion until antegrade sheath passed over lesion. Balloon expandable stent was delivered within antegrade sheath. Sheath was removed, and stent was implanted. We obtained an excellent outcome without complications.

  7. FiberNet--a new embolic protection device for carotid artery stenting.

    Science.gov (United States)

    Bauer, C; Franke, J; Bertog, S C; Woerner, V; Ghasemzadeh-Asl, S; Sievert, H

    2014-05-01

    Though distal filter protection during carotid stenting reduces the risk of cerebrovascular events, periprocedural stroke remains a risk despite their broad usage. This observation may be related to the pore size of common filters. The FiberNet distal filter system is unique by its very small pore size (40 µm) as well as its low profile and flexibility. Little data is available regarding the clinical performance and safety of this device. The aim was the evaluation of the safety of the FiberNet embolic protection system during carotid artery stenting. All consecutive patients treated with carotid stenting at our institution using the FiberNet device were systematically followed. Primary endpoint was the rate of all death and stroke within 30 days of the procedure. Carotid artery stenting using the FiberNet embolic protection system was performed in 54 patients. The procedure was technical successful in all patients. Three patients (5.5%) had a TIA. Amauosis fugax occurred in two patients (3.7%). One patient (1.9%) had a minor stroke with hemiparesis of the left arm and face which resolved completely within 48 hr after the procedure. No patient died or suffered a major stroke. The safety and feasibility of the FiberNet distal protection system appears to be at least equivalent to that reported in studies using conventional distal filter protection. Copyright © 2013 Wiley Periodicals, Inc.

  8. Device Data Protection in Mobile Healthcare Applications

    Science.gov (United States)

    Weerasinghe, Dasun; Rajarajan, Muttukrishnan; Rakocevic, Veselin

    The rapid growth in mobile technology makes the delivery of healthcare data and services on mobile phones a reality. However, the healthcare data is very sensitive and has to be protected against unauthorized access. While most of the development work on security of mobile healthcare today focuses on the data encryption and secure authentication in remote servers, protection of data on the mobile device itself has gained very little attention. This paper analyses the requirements and the architecture for a secure mobile capsule, specially designed to protect the data that is already on the device. The capsule is a downloadable software agent with additional functionalities to enable secure external communication with healthcare service providers, network operators and other relevant communication parties.

  9. Effective endovascular treatment of calcified femoropopliteal disease with directional atherectomy and distal embolic protection: final results of the DEFINITIVE Ca⁺⁺ trial.

    Science.gov (United States)

    Roberts, David; Niazi, Khusrow; Miller, William; Krishnan, Prakash; Gammon, Roger; Schreiber, Theodore; Shammas, Nicolas W; Clair, Daniel

    2014-08-01

    The purpose of the DEFINITIVE Ca(++) study was to evaluate the safety and effectiveness of directional atherectomy and distal embolic protection, used together to treat moderate to severely calcified femoropopliteal lesions. Despite advances in endovascular treatment modalities, treatment of calcified lesions remains a challenge. A total of 133 subjects with 168 moderate to severely calcified lesions were enrolled. Lesions were treated with directional atherectomy devices, coupled with distal embolic protection. The 30-day freedom from MAE rate was 93.1%. Per angiographic core laboratory assessment, the primary effectiveness endpoint (≤50% residual diameter stenosis) was achieved in 92.0% (lower confidence bound of 87.6%) of lesions. By core lab analysis, these results did not achieve the success criteria (90%) for the primary effectiveness objective. Per site assessment, the objective was met with the endpoint being achieved in 97.0% (lower confidence bound 93.8%). A mean residual diameter stenosis of 33.3% was achieved with the directional atherectomy device. This was further decreased to 24.1% with the use of adjunctive therapy. The proportion of asymptomatic subjects [Rutherford Clinical Category (RCC) = 0] increased from 0% at baseline to 52.3% at the 30-day follow-up visit. In total, 88.5% of subjects experienced an improvement of one or more Rutherford categories. The results of the DEFINITIVE Ca++ study demonstrate that the SilverHawk and TurboHawk atherectomy devices are safe and effective in the endovascular treatment of moderate to severely calcified lesions in the superficial femoral and/or popliteal arteries when used with the SpiderFX distal embolic protection device. © 2014 The Authors. Catheterization and Cardiovascular Interventions. Published by Wiley Periodicals, Inc.

  10. Effective Endovascular Treatment of Calcified Femoropopliteal Disease With Directional Atherectomy and Distal Embolic Protection: Final Results of the DEFINITIVE Ca++ Trial

    Science.gov (United States)

    Roberts, David; Niazi, Khusrow; Miller, William; Krishnan, Prakash; Gammon, Roger; Schreiber, Theodore; Shammas, Nicolas W; Clair, Daniel

    2014-01-01

    Objectives The purpose of the DEFINITIVE Ca++ study was to evaluate the safety and effectiveness of directional atherectomy and distal embolic protection, used together to treat moderate to severely calcified femoropopliteal lesions. Background Despite advances in endovascular treatment modalities, treatment of calcified lesions remains a challenge. Methods A total of 133 subjects with 168 moderate to severely calcified lesions were enrolled. Lesions were treated with directional atherectomy devices, coupled with distal embolic protection. Results The 30-day freedom from MAE rate was 93.1%. Per angiographic core laboratory assessment, the primary effectiveness endpoint (≤50% residual diameter stenosis) was achieved in 92.0% (lower confidence bound of 87.6%) of lesions. By core lab analysis, these results did not achieve the success criteria (90%) for the primary effectiveness objective. Per site assessment, the objective was met with the endpoint being achieved in 97.0% (lower confidence bound 93.8%). A mean residual diameter stenosis of 33.3% was achieved with the directional atherectomy device. This was further decreased to 24.1% with the use of adjunctive therapy. The proportion of asymptomatic subjects [Rutherford Clinical Category (RCC) = 0] increased from 0% at baseline to 52.3% at the 30-day follow-up visit. In total, 88.5% of subjects experienced an improvement of one or more Rutherford categories. Conclusions The results of the DEFINITIVE Ca++ study demonstrate that the SilverHawk™ and TurboHawk™ atherectomy devices are safe and effective in the endovascular treatment of moderate to severely calcified lesions in the superficial femoral and/or popliteal arteries when used with the SpiderFX™ distal embolic protection device. © 2014 Wiley Periodicals, Inc. PMID:24402764

  11. Developing biomedical devices design, innovation and protection

    CERN Document Server

    Andreoni, Giuseppe; Colombo, Barbara

    2013-01-01

    During the past two decades incredible progress has been achieved in the instruments and devices used in the biomedical field. This progress stems from continuous scientific research that has taken advantage of many findings and advances in technology made available by universities and industry. Innovation is the key word, and in this context legal protection and intellectual property rights (IPR) are of crucial importance. This book provides students and practitioners with the fundamentals for designing biomedical devices and explains basic design principles. Furthermore, as an aid to the dev

  12. Single-incision laparoscopic distal gastrectomy for early gastric cancer through a homemade single port access device.

    Science.gov (United States)

    Jiang, Zhi-Wei; Zhang, Shu; Wang, Gang; Zhao, Kun; Liu, Jiang; Ning, Li; Li, Jieshou

    2015-01-01

    We presented a series of single-incision laparoscopic distal gastrectomies for early gastric cancer patients through a type of homemade single port access device and some other conventional laparoscopic instruments. A single-incision laparoscopic distal gastrectomy with D1 + α lymph node dissection was performed on a 46 years old male patient who had an early gastric cancer. This single port access device has facilitated the conventional laparoscopic instruments to accomplish the surgery and we made in only 6 minutes. Total operating time for this surgery was 240 minutes. During the operation, there were about 100 milliliters of blood loss, and 17 lymph-nodes were retrieved. This homemade single port access device shows its superiority in economy and convenience for complex single-incision surgeries. Single-incision laparoscopic distal gastrectomy for early gastric cancer can be conducted by experienced laparoscopic surgeons. Fully take advantage of both SILS and fast track surgery plan can bring to successful surgeries with minimal postoperative pain, quicker mobilization, early recovery of intestinal function, and better cosmesis effect for the patients.

  13. Microprocessor protection devices: The present and the future

    Directory of Open Access Journals (Sweden)

    Gurevich Vladimir

    2008-01-01

    Full Text Available Paper presents the analysis of the basic constructive disadvantages of the present day microprocessor-based protective devices (MBR and offers the basic principles for creating a new MBR that can be used in newly constructed devices.

  14. Physical limitations of semiconductor devices defects, reliability and esd protection

    CERN Document Server

    Vashchenko, V A

    2008-01-01

    Provides an important link between the theoretical knowledge in the field of non-linier physics and practical application problems in microelectronics. This title focuses on power semiconductor devices and self-triggering pulsed power devices for ESD protection clamps.

  15. An application of residual current protective device at electrical installation

    International Nuclear Information System (INIS)

    Firman Silitonga

    2008-01-01

    In an electrical installation, a protection for overload and short circuit are always to be installed. In addition to the installation, it is necessary to be installed a protection device for residual current because both the short circuit and the overload device protection will not work for the residual current. The quantity of the residual current must be defined first at any electrical installation to define an appropriate residual current protection so that not every residual current will break the circuit down. This paper will explain a method how to install a residual protection device for 3500 VA or more at TN and TT of earthing system. (author)

  16. Techniques in cerebral protection.

    Science.gov (United States)

    Fanelli, Fabrizio; Bezzi, Mario; Boatta, Emanuele; Passariello, Roberto

    2006-10-01

    Carotid angioplasty and stenting is a valid alternative option to conventional carotid endarterectomy in the treatment of carotid artery stenosis. During the stenting process, however, distal embolization can occur with neurological consequences. To avoid this, cerebral protection devices have been introduced. Three principal types of protection system have been developed: distal balloon occlusion, distal filters and proximal protection with or without reversal of flow. As protection devices became the focus of interest by manufactures and physicians, several trials are going on worldwide to analyze the characteristics of each of them and to evaluate their efficacy to reduce the rate of distal embolization.

  17. Defining quality for distal pancreatectomy: does the laparoscopic approach protect patients from poor quality outcomes?

    Science.gov (United States)

    Baker, Marshall S; Sherman, Karen L; Stocker, Susan; Hayman, Amanda V; Bentrem, David J; Prinz, Richard A; Talamonti, Mark S

    2013-02-01

    Established systems for grading postoperative complications do not change the assigned grade when multiple interventions or readmissions are required to manage a complication. Studies using these systems may misrepresent outcomes for the surgical procedures being evaluated. We define a quality outcome for distal pancreatectomy (DP) and use this metric to compare laparoscopic distal pancreatectomy (LDP) to open distal pancreatectomy (ODP). Records for patients undergoing DP between January 2006 and December 2009 were reviewed. Clavien-Dindo grade IIIb, IV, and V complications were classified as severe adverse--poor quality--postoperative outcomes (SAPOs). II and IIIa complications requiring either significantly prolonged overall lengths of stay including readmissions within 90 days or more than one invasive intervention were also classified as SAPOs. By Clavien-Dindo system alone, 91 % of DP patients had either no complication or a low/moderate grade (I, II, IIIa) complication. Using our reclassification, however, 25 % had a SAPO. Patients undergoing LDP demonstrated a Clavien-Dindo complication profile identical to that for SDP but demonstrated significantly shorter overall lengths of stay, were less likely to require perioperative transfusion, and less likely to have a SAPO. Established systems undergrade the severity of some complications following DP. Using a procedure-specific metric for quality, we demonstrate that LDP affords a higher quality postoperative outcome than ODP.

  18. 14 CFR 25.1357 - Circuit protective devices.

    Science.gov (United States)

    2010-01-01

    ... system or connected equipment. (b) The protective and control devices in the generating system must be designed to de-energize and disconnect faulty power sources and power transmission equipment from their...

  19. 14 CFR 29.1357 - Circuit protective devices.

    Science.gov (United States)

    2010-01-01

    ... faults or serious malfunction of the system or connected equipment. (b) The protective and control devices in the generating system must be designed to de-energize and disconnect faulty power sources and...

  20. Automatic coordination of protection devices in distribution system

    International Nuclear Information System (INIS)

    Comassetto, L.; Bernardon, D.P.; Canha, L.N.; Abaide, A.R.

    2008-01-01

    Among the several components of distribution systems, protection devices present a fundamental importance, since they aim at keeping the physical integrity not only of the system equipment, but also of the electricians' team and the population in general. The existing tools today in the market that carry out the making of protection studies basically draw curves, and need direct user's interference for the protection devices adjustment and coordination analyses of selectivity, being susceptible to the user's mistakes and not always considering the best technical and economical application. In Brazil, the correct application of the protection devices demand a high amount of time, being extremely laborious due to the great number of devices (around 200 devices), besides the very dynamic behaviour of distribution networks and the need for constant system expansion. This article presents a computational tool developed with the objective of automatically determining the adjustments of all protection devices in the distribution networks to obtain the best technical application, optimizing its performance and making easier protection studies. (author)

  1. New concept of microprocessor protective devices design

    Directory of Open Access Journals (Sweden)

    Gurevich Vladimir

    2010-01-01

    Full Text Available Transition from electromechanical to digital protective relays is accompanied with serious technical problems. The author offers a new approach in designing the digital relays capable of solving these problems. It is proposed to construct digital relays in the form of standard modules from which it would be possible to assemble the digital relay in the same way as now a personal computer.

  2. 30 CFR 77.401 - Stationary grinding machines; protective devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Stationary grinding machines; protective... OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.401 Stationary grinding machines; protective devices. (a) Stationary grinding machines other than special bit grinders shall be equipped with...

  3. 30 CFR 75.1723 - Stationary grinding machines; protective devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Stationary grinding machines; protective....1723 Stationary grinding machines; protective devices. (a) Stationary grinding machines other than... the wheel. (3) Safety washers. (b) Grinding wheels shall be operated within the specifications of the...

  4. Adjustable radiation protection device of the fluoroscope DG 10

    International Nuclear Information System (INIS)

    Hoermann, D.

    1980-01-01

    In cooperation with the 'VEB Transformatoren- und Roentgenwerk Hermann Matern', Dresden, an adjustable radiation protection device has been developed. This supplementary equipment for fluoroscopes ensures a sufficient protection of the gonads against undesirable X radiation, can be handled easily and does not annoy patients, esp. children

  5. Device for protecting deformations of reactor cores

    International Nuclear Information System (INIS)

    Kato, Yasuyoshi; Urushihara, Hiroshi.

    1975-01-01

    Object: To provide a fluid pressure cylinder, which is operated according to change in temperature of coolant for a reactor to restrain or release a core, to simply and effectively protect deformation of the core. Structure: A closed fluid pressure cylinder interiorly filled with suitable fluid is disposed in peripherally equally spaced relation in an annular space between a core barrel of a reactor and a reactor vessel. A piston is mounted in fluid-tight fashion in a plurality of piston openings made in the cylinder, the piston being slidably moved according to expansion and contraction of the fluid filled in the cylinder. The piston has a movable frame mounted at the foremost end thereof, the movable frame being moved integral with the piston, and the surface opposite the mount thereof biasing the outermost peripheral surface of the core. (Kamimura, M.)

  6. Overcurrent protection device for neutral beam sources

    International Nuclear Information System (INIS)

    Praeg, W.F.

    1983-01-01

    Electrical loads connected to capacitance elements in high voltage direct current systems are protected from damage caused by capacitance discharge overcurrents by connecting a longitudinal inductor between the capacitance element and the load. The inductor comprises a bifilar winding wound about a magnetic core, which forms an incomplete magnetic circuit. A diode is connected across a portion of the bifilar winding. Most of the energy discharged from the capacitance element is stored in the inductor and then dissipated, away from the load, in an L-R circuit comprising the diode and the coil winding. Multiple high voltage circuits having capacitance elements may be connected to loads through bifilar windings all wound about the aforementioned magnetic core

  7. Distal and Proximal Religiosity as Protective Factors for Adolescent and Emerging Adult Alcohol Use

    Directory of Open Access Journals (Sweden)

    Michelle V. Porche

    2015-04-01

    Full Text Available Data from emerging adults (ages 18–29, N = 900 in the National Comorbidity Survey Replication Study was used to examine the influence of childhood and emerging adult religiosity and religious-based decision-making, and childhood adversity, on alcohol use. Childhood religiosity was protective against early alcohol use and progression to later abuse or dependence, but did not significantly offset the influence of childhood adversity on early patterns of heavy drinking in adjusted logistic regression models. Religiosity in emerging adulthood was negatively associated with alcohol use disorders. Protective associations for religiosity varied by gender, ethnicity and childhood adversity histories. Higher religiosity may be protective against early onset alcohol use and later development of alcohol problems, thus, should be considered in prevention programming for youth, particularly in faith-based settings. Mental health providers should allow for integration of clients’ religiosity and spirituality beliefs and practices in treatment settings if clients indicate such interest.

  8. Consumer protection issues in energy: a guide for attorneys general. Insulation, solar, automobile device, home devices

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Harry I.; Hulse, William S.; Jones, Robert R.; Langer, Robert M.; Petrucelli, Paul J.; Schroeder, Robert J.

    1979-11-01

    The guide attempts to bring together two important and current issues: energy and consumer protection. Perhaps the most basic consumer-protection issue in the energy area is assuring adequate supplies at adequate prices. It is anticipated, though, that consumers will want to consider new ways to lower enegy consumption and cost, and will thus be susceptible to fraudulent energy claims. Information is prepared on insulation, solar, energy-saving devices for the home, and energy-saving devices for the automobile.

  9. Protective device for organs exposed to medical X-radiation

    International Nuclear Information System (INIS)

    Zimmer, K.

    1978-01-01

    The protective device for male or female gonads consists of a protective screen made of hard lead coated with silicon caoutchouc, a flexible supporting arm, and a base plate on which the supporting arm for the protective screen is monted. The protective screen has got the shape of a dish resp. a pear-shaped contour for male resp. female persons. The base may be arranged on a Bucky table between the legs of the person to be examined by means of suction cups. (DG) [de

  10. Randomized comparison of distal and proximal cerebral protection during carotid artery stenting.

    Science.gov (United States)

    Cano, Manuel N; Kambara, Antônio M; de Cano, Silvia J F; Pezzi Portela, Luiz Antônio; Paes, Ângela Tavares; Costa, J Ribamar; Abizaid, Alexandre Antônio Cunha; Moreira, Samuel Martins; Sousa, Amanda G M R; Sousa, J Eduardo Moraes Rego

    2013-11-01

    This study sought to randomly compare cerebral protection with ANGIOGUARD (Cordis Corporation, Bridgewater, New Jersey) with Mo.Ma (Invatec/Medtronic Vascular Inc, Santa Rosa, California) during carotid artery stenting (CAS), using diffusion-weighted magnetic resonance imaging (DW-MRI) to detect new ischemic cerebral lesions. The number, size, and location of lesions were analyzed. The choice of the type of cerebral protection during CAS is controversial. From July 2008 to July 2011, 60 patients undergoing CAS were randomized to ANGIOGUARD or Mo.Ma, distributed by chance, 30 patients for each group. All patients underwent DW-MRI before and after CAS. An independent neuroradiologist blinded to the cerebral protection used analyzed the images. Univariate and multivariate logistic models were fitted to analyze new ischemic lesions. Alternatively, a propensity score approach was used to reduce the bias due to differences between the groups. For the number of lesions, we used Poisson regression models. New ischemic lesions seen on DW-MRI were present in 63.3% of the ANGIOGUARD group versus 66.7% of the Mo.Ma cohort (p = 0.787). The number of ischemic cerebral lesions per patient, when present, was significantly lower in the Mo.Ma group (a median of 6 lesions per patient vs. a median of 10 in the ANGIOGUARD, p minor stroke during CAS (1.66%). New ischemic lesions seen on DW-MRI were present in both groups in >60%, but the number of lesions per patient was greater in the ANGIOGUARD group. No death or disabling stroke occurred during at least 1 year of follow-up in both cohorts. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Investigation of surge protective devices operation of a wind generator

    International Nuclear Information System (INIS)

    Dimitrov, D.; Vasileva, M.

    2008-01-01

    The interest to the investments in a wind energetics increases in the last years. The wind energetics is the fastest developing direction in the energetics in global scale. The wind energy is more attractive because its prices are lower in comparison of the other technologies for generating energy. The right choice of the surge protective devices has the important meaning on building and exploitation of the wind generators. The aim of this paper is investigation of the surge protective devices operation when they are installation to a wind generator. (authors)

  12. Endovascular rescue of a fused monorail balloon and cerebral protection device.

    Science.gov (United States)

    Campbell, John E; Bates, Mark C; Elmore, Michael

    2007-08-01

    To present a case of successful endovascular retrieval of a monorail predilation balloon fused to an embolic protection device (EPD) in the distal internal carotid artery (ICA) of a high-risk symptomatic patient. A 60-year-old man with documented systemic atherosclerotic disease had a severe (>70%) restenosis in the left ICA 3 years after endarterectomy. He was scheduled for carotid artery stenting (CAS) with cerebral protection; however, he developed unstable angina and was transferred to our facility, where the admitting team decided that staged CAS followed by coronary bypass grafting would be the best option. During the CAS procedure, a 6-mm AccuNet filter was passed across the lesion via a 6-F carotid sheath and deployed in the distal ICA without incident. However, the 4-x20-mm predilation monorail balloon was then advanced without visualizing the markers, resulting in inadvertent aggressive interaction that trapped the balloon's tip in the filter. Several maneuvers to separate the devices were unsuccessful. Finally, the filter/balloon combination was moved gently retrograde until the balloon was straddling the subtotal ICA lesion. The lesion was dilated to 4 mm with the balloon, and the sheath was gently advanced across the lesion as the balloon was deflated. Angiography excluded interval occlusion of the filter from the embolic debris during the aforementioned aggressive maneuvers and documented antegrade flow. The filter was slowly withdrawn into the 6-F sheath with simultaneous aspiration. A second 6-mm filter was deployed, and the procedure was completed satisfactorily. The patient did well, with no neurological sequelae. EPDs are an essential in carotid artery stenting and, keeping in mind the potential risks associated with their use, will help the operator avoid complications such as this one.

  13. Method of and device for querying of protected structured data

    NARCIS (Netherlands)

    Jonker, Willem; Brinkman, Richard; Doumen, J.M.; Schoenmakers, Berry

    2005-01-01

    Method of and device for querying of protected data structured in the form of a tree. A corresponding tree of node polynomials is constructed such that each node polynomial evaluates to zero for an input equal to an identifier assigned to a node name occurring in a branch of the data tree starting

  14. Method of and device for querying of protected structured data

    NARCIS (Netherlands)

    Brinkman, Richard; Doumen, J.M.; Jonker, Willem; Schoenmakers, B.

    Method of and device for querying of protected data structured in the form of a tree. A corresponding tree of node polynomials is constructed such that each node polynomial evaluates to zero for an input equal to an identifier assigned to a node name occurring in a branch of the data tree starting

  15. Awareness and utilization of protective eye device among welders in ...

    African Journals Online (AJOL)

    Ramakantb

    was a high level of awareness of protective eye devices among the welders (367, 90.6%), being higher among arc welders compared ... each respondent in the field. The welders' ... Thermal retinal damage can also occur from near infrared ...

  16. Improving 200 MW NDHR reactor protection system with GAL devices

    International Nuclear Information System (INIS)

    Shi Mingde; Li Duo; Xie Zhengguo

    1999-01-01

    The emergence of General Array Logic (GAL), a fairly new type of logic devices with the characteristics of user-definable logic functions, have led to a revolutionary change in the design of logical circuits. The improvements of the reactor protection system for the 200 MW nuclear district heating reactor (NDHR) using GAL are covered

  17. Neutron protection material and neutron protection devices made of such material

    International Nuclear Information System (INIS)

    Ries, W.

    1984-01-01

    This is concerned with a neutron protection material made of thermoplastic or thermosetting plastic from high molecule hydrocarbon compounds with particularly high hydrogen and carbon contents as braking or shielding material (moderator) for fast neutrons. The plastic can contain boron for absorbing low energy neutrons. The material is used to manufacture foil, plates, pipes, shielding walls, components, bodies for radiation protection equipment, devices and plant and for neutron protection clothes. (orig./HP) [de

  18. Dependable Design Flow for Protection Systems using Programmable Logic Devices

    CERN Document Server

    Kwiatkowski, M

    2011-01-01

    Programmable Logic Devices (PLD) such as Field Programmable Gate Arrays (FPGA) are becoming more prevalent in protection and safety-related electronic systems. When employing such programmable logic devices, extra care and attention needs to be taken. The final synthesis result, used to generate the bit-stream to program the device, must be shown to meet the design’s requirements. This paper describes how to maximize confidence using techniques such as Formal Methods, exhaustive Hardware Description Language (HDL) code simulation and hardware testing. An example is given for one of the critical functions of the Safe Machine Parameters (SMP) system, used in the protection of the Large Hadron Collider (LHC) at CERN. CERN is also working towards an adaptation of the IEC- 61508 lifecycle designed for Machine Protection Systems (MPS), and the High Energy Physics environment, implementation of a protection function in FPGA code is only one small step of this lifecycle. The ultimate aim of this project is to cre...

  19. The radiation protective devices for interventional procedures using computed tomography

    International Nuclear Information System (INIS)

    Iida, Hiroji; Chabatake, Mitsuhiro; Shimizu, Mitsuru; Tamura, Sakio

    2002-01-01

    A scattered dose and a surface dose from phantom measurements during interventional procedures with computed tomography (IVR-CT) were evaluated. To reduce the personnel exposure in IVR-CT, the new protective devices were developed and its effect evaluated. Two radiation protection devices were experimentally made using a lead vinyl sheet with lead equivalent 0.125 mmPb. The first device is a lead curtain which shields the space of CT-gantry and phantom for the CT examination. The second device is a lead drape which shields on the phantom surface adjacent to the scanning plane for the CT-fluoroscopy. Scattered dose and phantom surface dose were measured with an abdominal phantom during Cine-CT (130 kV, 150 mA, 5 seconds, 10 mm section thickness). They were measured by using ionization chamber dosimeter. They were measured with and without a lead curtain and a lead drape. Scattered dose rate was measured at distance of 50-150 cm from the scanning plane. And, surface dose was measured at distance of 4-21 cm from the scanning plane on the phantom. On operator's standing position, scattered dose rates were from 8.4 to 11.6 μGy/sec at CT examination. The lead curtain and the lead drape reduced scattered dose rate at distance of 50 cm from the scanning plane by 66% and 58.3% respectively. Surface dose rate were 118 μGy/sec at distance of 5 cm from the scanning plane at CT-fluoroscopy. The lead drape reduced the surface dose by 60.5%. High scattered exposure to personnel may occur during interventional procedures using CT. They were considerably reduced during CT-arteriography by attaching the lead curtain in CT equipment. And they were substantially reduced during CT-fluoroscopy by placing the lead drape adjacent to the scanning plane, in addition, operator's hand would be protected from unnecessary radiation scattered by phantom. It was suggested that the scattered exposure to personnel could be sufficiently reduced by using radiation protection devices in IVR-CT. The

  20. Protective device for the head of a gushing well

    Energy Technology Data Exchange (ETDEWEB)

    Kutepov, A.I.; Prokopov, O.I.

    1982-01-01

    A protective device is proposed for the head of a gushing well. It includes a housing with assembly for attachment to the pipe string. It is distinguished by the fact that in order to simplify insulation of the device at the well head and to improve its reliable operation, the housing is made in the form of sections, each of which is made in the form of a crimped sleeve with upper and lower flanges on the ends. The lower flange is equipped with a guide bushing installed inside the sleeve and clamps for attaching it in relation to the upper flange.

  1. DISTAL MYOPATHIES

    Science.gov (United States)

    Dimachkie, Mazen M.; Barohn, Richard J.

    2014-01-01

    Over a century ago, Gowers described two young patients in whom distal muscles weakness involved the hand, foot, sternocleidomastoid, and facial muscles in the other case the shoulder and distal leg musculature. Soon after, , similar distal myopathy cases were reported whereby the absence of sensory symptoms and of pathologic changes in the peripheral nerves and spinal cord at postmortem examination allowed differentiation from Charcot-Marie-Tooth disease. In 1951, Welander described autosomal dominant (AD) distal arm myopathy in a large Scandanavian cohort. Since then the number of well-characterized distal myopathies has continued to grow such that the distal myopathies have formed a clinically and genetically heterogeneous group of disorders. Affected kindred commonly manifest weakness that is limited to foot and toe muscles even in advanced stages of the disease, with variable mild proximal leg, distal arm, neck and laryngeal muscle involvement in selected individuals. An interesting consequence of the molecular characterization of the distal myopathies has been the recognition that mutation in a single gene can lead to more than one clinical disorder. For example, Myoshi myopathy (MM) and limb girdle muscular dystrophy (LGMD) type 2B are allelic disorders due to defects in the gene that encodes dysferlin. The six well described distal myopathy syndromes are shown in Table 1. Table 2 lists advances in our understanding of the myofibrillar myopathy group and Table 3 includes more recently delineated and less common distal myopathies. In the same manner, the first section of this review pertains to the more traditional six distal myopathies followed by discussion of the myofibrillar myopathies. In the third section, we review other clinically and genetically distinctive distal myopathy syndromes usually based upon single or smaller family cohorts. The fourth section considers other neuromuscular disorders that are important to recognize as they display prominent

  2. Device for the burst protection of nuclear reactor pressure vessels

    International Nuclear Information System (INIS)

    Daublebsky, P.

    1976-01-01

    The burst protection device has a hood over top and bottom of the pressure vessel with superimposed hinged supports lying in their turn against supporting rings which are connected with each other by vertical bracing. It is proposed to place an intermediate layer between hoods and vertical bracing absorbing thermal stresses, i.e. deforming plastically with gradually increasing pressure, but behaving like a rigid body in the case of shock loads. As a material lead e.g. is proposed. (UWI) [de

  3. Turbine protecting device in a BWR type nuclear power plant

    International Nuclear Information System (INIS)

    Kasuga, Hajime; Oka, Yoko.

    1984-01-01

    Purpose: To prevent highly humid steams from flowing into the turbine upon abnormal reduction in the reactor water level in order to ensure the turbine soundness, as well as in order to trip the turbine with no undesired effect on the reactor. Constitution: A protection device comprising a judging device and a timer are disposed in a BWR type reactor, in order to control a water level signal from a reactor water level gage. If the reactor water level is reduced during rated power operation, steams are kept to be generated due to decay heat although reactor is scramed. When a signal from the reactor water level detector is inputted to the protection device, a trip signal is outputted by way of a judging device after 15 second by means of the timer, when the main steam check valve is closed to trip the turbine. With this delay of time, abrupt increase in the pressure of the reactor due to sudden shutdown can be prevented. (Nakamoto, H)

  4. Carotid Stenting with Distal Protection in High-Surgical-Risk Patients: One-Year Results of the ASTI Trial

    Energy Technology Data Exchange (ETDEWEB)

    Bosiers, Marc, E-mail: marc.bosiers@telenet.be [A.Z. Sint-Blasius, Department of Vascular Surgery (Belgium); Scheinert, Dierk, E-mail: dierk.scheinert@gmx.de [Park Hospital, Center for Vascular Medicine-Angiology and Vascular Surgery (Germany); Mathias, Klaus, E-mail: k.mathias@asklepios.com [Klinikum Dortmund GmbH (Germany); Langhoff, Ralf, E-mail: ralf.langhoff@sankt-gertrauden.de [Sankt Gertrauden-Krankenhaus (Germany); Mudra, Harald, E-mail: haraldmudra@aol.com [Klinikum Neuperlach (Germany); Diaz-Cartelle, Juan, E-mail: juan.diazcartelle@bostonscientific.com [One Boston Scientific Place, Boston Scientific Corporation (United States)

    2015-04-15

    PurposeThis prospective, multicenter, nonrandomized study evaluated the periprocedural and 1-year outcomes in high-surgical-risk patients with carotid artery stenosis treated with the Adapt Carotid Stent plus FilterWire EZ distal protection catheter (Boston Scientific Corporation, Natick, MA).Materials and MethodsThe study enrolled 100 patients (32 symptomatic, 63 asymptomatic, 5 unknown) at high risk for carotid endarterectomy due to prespecified anatomical criteria and/or medical comorbidities. Thirty-day and 1-year follow-up included clinical evaluation, carotid duplex ultrasound, and independent neurologic and NIH stroke scale assessments. One-year endpoints included the composite rate of major adverse events (MAE), defined as death, stroke, and myocardial infarction (MI) and the rates of late ipsilateral stroke (31–365 days), target lesion revascularization, and in-stent restenosis.ResultsOf the 100 enrolled patients, technical success was achieved in 90.9 % (90/99). The 30-day MAE rate (5.1 %) consisted of major stroke (2.0 %) and minor stroke (3.1 %); no deaths or MIs occurred. The 1-year MAE rate (12.2 %) consisted of death, MI, and stroke rates of 4.4, 3.3, and 8.9 %, respectively. Late ipsilateral stroke (31–365 days) rate was 1.1 %. Symptomatic patients had higher rates of death (11.1 vs. 1.7 %) and MI (7.4 vs. 1.7 %), but lower rates of major (7.4 vs. 10.0 %) and minor stroke (0.0 vs. 6.7 %), compared with asymptomatic patients.ConclusionResults through 1 year postprocedure demonstrated that carotid artery stenting with Adapt Carotid Stent and FilterWire EZ is safe and effective in high-risk-surgical patients.

  5. Carotid Stenting with Distal Protection in High-Surgical-Risk Patients: One-Year Results of the ASTI Trial

    International Nuclear Information System (INIS)

    Bosiers, Marc; Scheinert, Dierk; Mathias, Klaus; Langhoff, Ralf; Mudra, Harald; Diaz-Cartelle, Juan

    2015-01-01

    PurposeThis prospective, multicenter, nonrandomized study evaluated the periprocedural and 1-year outcomes in high-surgical-risk patients with carotid artery stenosis treated with the Adapt Carotid Stent plus FilterWire EZ distal protection catheter (Boston Scientific Corporation, Natick, MA).Materials and MethodsThe study enrolled 100 patients (32 symptomatic, 63 asymptomatic, 5 unknown) at high risk for carotid endarterectomy due to prespecified anatomical criteria and/or medical comorbidities. Thirty-day and 1-year follow-up included clinical evaluation, carotid duplex ultrasound, and independent neurologic and NIH stroke scale assessments. One-year endpoints included the composite rate of major adverse events (MAE), defined as death, stroke, and myocardial infarction (MI) and the rates of late ipsilateral stroke (31–365 days), target lesion revascularization, and in-stent restenosis.ResultsOf the 100 enrolled patients, technical success was achieved in 90.9 % (90/99). The 30-day MAE rate (5.1 %) consisted of major stroke (2.0 %) and minor stroke (3.1 %); no deaths or MIs occurred. The 1-year MAE rate (12.2 %) consisted of death, MI, and stroke rates of 4.4, 3.3, and 8.9 %, respectively. Late ipsilateral stroke (31–365 days) rate was 1.1 %. Symptomatic patients had higher rates of death (11.1 vs. 1.7 %) and MI (7.4 vs. 1.7 %), but lower rates of major (7.4 vs. 10.0 %) and minor stroke (0.0 vs. 6.7 %), compared with asymptomatic patients.ConclusionResults through 1 year postprocedure demonstrated that carotid artery stenting with Adapt Carotid Stent and FilterWire EZ is safe and effective in high-risk-surgical patients

  6. Negative pressure wound therapy using a portable single-use device for free skin grafts on the distal extremity in seven dogs.

    Science.gov (United States)

    Miller, A J; Cashmore, R G; Marchevsky, A M; Havlicek, M; Brown, P M; Fearnside, S M

    2016-09-01

    Retrospective study to describe clinical experience with a portable single-use negative pressure wound therapy device after application of full-thickness meshed skin grafts to wounds on the distal extremities of seven dogs. Seven dogs were treated with portable NPWT after receiving skin grafts; six as the result of tumour resection and one for traumatic injury. Medical records were reviewed and data recorded on patient signalment, cause and location of wound, surgical technique, application and maintenance of portable NPWT, graft survival and outcome, and complications encountered with the system. NPWT was provided for between 4 and 7 days. Five patients were discharged from hospital during the treatment period. Application and maintenance of the portable device was technically easy and no major complications were encountered. Minor complications consisted of fluid accumulation in the evacuation tubing. All dogs achieved 100% graft survival. Application and maintenance of the portable device was technically straightforward. All dogs receiving portable NPWT after transfer of a free skin graft to the distal extremity had a successful outcome. © 2016 Australian Veterinary Association.

  7. Respiratory protective device design using control system techniques

    Science.gov (United States)

    Burgess, W. A.; Yankovich, D.

    1972-01-01

    The feasibility of a control system analysis approach to provide a design base for respiratory protective devices is considered. A system design approach requires that all functions and components of the system be mathematically identified in a model of the RPD. The mathematical notations describe the operation of the components as closely as possible. The individual component mathematical descriptions are then combined to describe the complete RPD. Finally, analysis of the mathematical notation by control system theory is used to derive compensating component values that force the system to operate in a stable and predictable manner.

  8. First-in-man use of a novel embolic protection device for patients undergoing transcatheter aortic valve implantation.

    Science.gov (United States)

    Naber, Christoph K; Ghanem, Alexander; Abizaid, Alexander A; Wolf, Alexander; Sinning, Jan-Malte; Werner, Nikos; Nickenig, Georg; Schmitz, Thomas; Grube, Eberhard

    2012-05-15

    We describe the first-in-human experience with a novel cerebral embolic protection device used during transcatheter aortic valve implantation (TAVI). One current challenge of TAVI is the reduction of procedural stroke. Procedural mobilisation of debris is a known source of cerebral embolisation. Mechanical protection by transient filtration of cerebral blood flow might reduce the embolic burden during TAVI. We aimed to evaluate the feasibility and safety of the Claret CE Pro™ cerebral protection device in patients undergoing TAVI. Patients scheduled for TAVI were prospectively enrolled at three centres. The Claret CE Pro™ (Claret Medical, Inc. Santa Rosa, CA, USA) cerebral protection device was placed via the right radial/brachial artery prior to TAVI and was removed after the procedure. The primary endpoint was technical success rate. Secondary endpoints encompassed procedural and 30-day stroke rates, as well as device-related complications. Deployment of the Claret CE Pro™ cerebral protection device was intended for use in 40 patients, 35 devices were implanted into the aortic arch. Technical success rate with delivery of the proximal and distal filter was 60% for the first generation device and 87% for the second-generation device. Delivery times for the first-generation device were 12.4±12.1 minutes and 4.4 ± 2.5 minutes for the second-generation device (pto the Claret CE Pro System was 19.6 ± 3.8 ml. Captured debris was documented in at least 19 of 35 implanted devices (54.3%). No procedural transient ischaemic attacks, minor strokes or major strokes occurred. Thirty-day follow-up showed one minor stroke occurring 30 days after the procedure, and two major strokes both occurring well after the patient had completed TAVI. The use of the Claret CE Pro™ system is feasible and safe. Capture of debris in more than half of the patients provides evidence for the potential to reduce the procedural cerebral embolic burden utilising this dedicated filter

  9. Distal mdx muscle groups exhibiting up-regulation of utrophin and rescue of dystrophin-associated glycoproteins exemplify a protected phenotype in muscular dystrophy

    Science.gov (United States)

    Dowling, Paul; Culligan, Kevin; Ohlendieck, Kay

    2002-02-01

    Unique unaffected skeletal muscle fibres, unlike necrotic torso and limb muscles, may pave the way for a more detailed understanding of the molecular pathogenesis of inherited neuromuscular disorders and help to develop new treatment strategies for muscular dystrophies. The sparing of extraocular muscle in Duchenne muscular dystrophy is mostly attributed to the special protective properties of extremely fast-twitching small-diameter fibres, but here we show that distal muscles also represent a particular phenotype that is more resistant to necrosis. Immunoblot analysis of membranes isolated from the well established dystrophic animal model mdx shows that, in contrast to dystrophic limb muscles, the toe musculature exhibits an up-regulation of the autosomal dystrophin homologue utrophin and a concomitant rescue of dystrophin-associated glycoproteins. Thus distal mdx muscle groups provide a cellular system that naturally avoids myofibre degeneration which might be useful in the search for naturally occurring compensatory mechanisms in inherited skeletal muscle diseases.

  10. Relationship Between the Elevated Muscle FDG Uptake in the Distal Upper Extremities on PET/CT Scan and Prescan Utilization of Mobile Devices in Young Patients.

    Science.gov (United States)

    Bai, Xia; Wang, Xuemei; Zhuang, Hongming

    2018-03-01

    It is common to notice increased FDG activity in the muscles of the forearms or hands on PET/CT images. The purpose of this study was to determine relationship between the prevalence of increased FDG activity in the forearms or hands and using mobile devices prior to the FDG PET/CT study. A total of 443 young patients with ages between 5 and 19 years who underwent FDG PET/CT scan were included in this retrospective analysis. All patients had FDG PET/CT with their arms within the field of views. The images were reviewed for elevated activity in the muscles of the distal upper extremities (DUEs), which include forearms and hands. The preimaging questionnaire/interview records regarding using mobile devices prior to FDG PET/CT were also reviewed and compared with the imaging findings. Most patients (72.0% [319/443]) used mobile devices more than 60 minutes in the period of 24 hours prior to the FDG PET/CT study. Elevated uptake in the muscles in the DUEs was observed in 38.6% (123/319) of these patients. In contrast, among 124 patients who did not use the mobile devices or used the mobile device minimally prior to the study, only 6.5% (8/124) of them had elevated FDG activity in the DUEs. The difference persisted following stratification analysis for sex, age, and serum glucose level in our patient population. Increased FDG uptake in the muscles of the DUEs in young patients is commonly seen in those who used mobile devices prior to PET/CT study. Recommendation should be considered to reduce using mobile devices prior to FDG PET/CT study in young patient population.

  11. Safety and effectiveness of the INVATEC MO.MA proximal cerebral protection device during carotid artery stenting: results from the ARMOUR pivotal trial.

    Science.gov (United States)

    Ansel, Gary M; Hopkins, L Nelson; Jaff, Michael R; Rubino, Paolo; Bacharach, J Michael; Scheinert, Dierk; Myla, Subbarao; Das, Tony; Cremonesi, Alberto

    2010-07-01

    The multicenter ARMOUR (ProximAl PRotection with the MO.MA Device DUring CaRotid Stenting) trial evaluated the 30-day safety and effectiveness of the MO.MA Proximal Cerebral Protection Device (Invatec, Roncadelle, Italy) utilized to treat high surgical risk patients undergoing carotid artery stenting (CAS). Distal embolic protection devices (EPD) have been traditionally utilized during CAS. The MO.MA device acts as a balloon occlusion "endovascular clamping" system to achieve cerebral protection prior to crossing the carotid stenosis. This prospective registry enrolled 262 subjects, 37 roll-in and 225 pivotal subjects evaluated with intention to treat (ITT) from September 2007 to February 2009. Subjects underwent CAS using the MO.MA device. The primary endpoint, myocardial infarction, stroke, or death through 30 days (30-day major adverse cardiac and cerebrovascular events [MACCE]) was compared to a performance goal of 13% derived from trials utilizing distal EPD. For the ITT population, the mean age was 74.7 years with 66.7% of the cohort being male. Symptomatic patients comprised 15.1% and 28.9% were octogenarians. Device success was 98.2% and procedural success was 93.2%. The 30-day MACCE rate was 2.7% [95% CI (1.0-5.8%)] with a 30-day major stroke rate of 0.9%. No symptomatic patient suffered a stroke during this trial. The ARMOUR trial demonstrated that the MO.MA(R) Proximal Cerebral Protection Device is safe and effective for high surgical risk patients undergoing CAS. The absence of stroke in symptomatic patients is the lowest rate reported in any independently adjudicated prospective multicenter registry trial to date. (c) 2010 Wiley-Liss, Inc.

  12. Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting. Comparison of several anti-embolic protection devices

    International Nuclear Information System (INIS)

    Taha, M.M.; Maeda, Masayuki; Sakaida, Hiroshi

    2009-01-01

    Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm 3 vs. 86.9 mm 3 , respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm 3 ) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm 3 and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions. (author)

  13. Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting: Comparison of several anti-embolic protection devices.

    Science.gov (United States)

    Taha, Mahmoud M; Maeda, Masayuki; Sakaida, Hiroshi; Kawaguchi, Kenji; Toma, Naoki; Yamamoto, Akitaka; Hirose, Tomofumi; Miura, Youichi; Fujimoto, Masashi; Matsushima, Satoshi; Taki, Waro

    2009-09-01

    Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm(3) vs. 86.9 mm(3), respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm(3)) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm(3) and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions.

  14. Filtration of nanoparticles - Application to respiratory protecting devices

    International Nuclear Information System (INIS)

    Brochot, C.

    2012-01-01

    This study aims to determine how the respiratory protective devices (RPD), whose performances are qualified for particles above 100 nm, are effective for nanoparticles. Indeed, if the use of a collective filtration is inadequate, wearing a RPD is the last protection recommended. A literature review showed that no research concerned the effectiveness of half-masks for nanoparticles. The test bench ETNA has been sized and built to overcome these lacks. Two half masks were tested according to different configurations: constant flow rate and cyclic flow rate (average flow of 84 L /min), particle size (from 5 to 100 nm), positions of the mask (sealed, usual, or with calibrated leaks). The results show that, since the RPD contain high efficiency filter media (without charged fibers) for the most penetrating particle size (100 nm - 300 nm), the RPD is more efficient for nanoparticles. Furthermore, the results obtained in the presence of actual and calibrated leaks, highlighted the importance of face seal leakages in determining the performance of RPD. A model for calculating the protection factor was established based on the balance between the airflow through the filter and the leak. This model was validated using measurements obtained in the presence of calibrated leaks, and applied for the analysis of our results in usual position. (author)

  15. Problematic radiation protective devices for X-ray diagnostics

    International Nuclear Information System (INIS)

    Beck, A.; Nanko, N.; Bruggmoser, G.; Eble, M.

    1988-01-01

    The authors report experimental test results of radiation safety glasses with a lead equivalence of 0.5 mm Pb. The glasses were tested on a phantom, with various radiation projections, for their shielding effect with regard to the eye lens. The protective effect at AP projection was 90%, which corresponds to the data given by the manufacturer. But in most cases of interventional radiology, the examiner's eyes are exposed to lateral radiation, due to the positioning of the monitor. In these cases, reflected radiation at the side of the glasses facing the eye may induce a dose to the lens that can be fourfold the dose received without wearing the glasses, so that wearing these glasses may enhance the hazard. Another protective device tested was lead-coated gloves. The manufacturer promises a protective effect of 50% at 100 kV. The experimental test data, obtained by taking into account technical characteristics of angiographic components, confirm a radiation shielding of about 20%. (orig./HP) [de

  16. Increased rate of stent thrombosis and target lesion revascularization after filter protection in primary percutaneous coronary intervention for ST-segment elevation myocardial infarction: 15-month follow-up of the DEDICATION (Drug Elution and Distal Protection in ST Elevation Myocardial Infarction) trial

    DEFF Research Database (Denmark)

    Kaltoft, Anne; Kelbaek, Henning; Kløvgaard, Lene

    2010-01-01

    The purpose of this study was to evaluate the long-term effects of distal protection during percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI).......The purpose of this study was to evaluate the long-term effects of distal protection during percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI)....

  17. Aging assessment of surge protective devices in nuclear power plants

    International Nuclear Information System (INIS)

    Davis, J.F.; Subudhi, M.; Carroll, D.P.

    1996-01-01

    An assessment was performed to determine the effects of aging on the performance and availability of surge protective devices (SPDs), used in electrical power and control systems in nuclear power plants. Although SPDs have not been classified as safety-related, they are risk-important because they can minimize the initiating event frequencies associated with loss of offsite power and reactor trips. Conversely, their failure due to age might cause some of those initiating events, e.g., through short circuit failure modes, or by allowing deterioration of the safety-related component(s) they are protecting from overvoltages, perhaps preventing a reactor trip, from an open circuit failure mode. From the data evaluated during 1980--1994, it was found that failures of surge arresters and suppressers by short circuits were neither a significant risk nor safety concern, and there were no failures of surge suppressers preventing a reactor trip. Simulations, using the ElectroMagnetic Transients Program (EMTP) were performed to determine the adequacy of high voltage surge arresters

  18. Attenuation of earmuffs used simultaneously with respiratory protective devices

    Directory of Open Access Journals (Sweden)

    Emil Kozłowski

    2017-06-01

    Full Text Available Background: In the work environment, apart from the noise, employees may be exposed to other harmful factors. Therefore, they wear hearing protectors and other personal protective equipment. The aim of the study was to determine whether simultaneous use of earmuffs and respiratory protective devices affects the attenuation of earmuffs. Material and Methods: The study was conducted in laboratory conditions using the subjective REAT (Real Ear Attenuation at Threshold and objective MIRE (Microphone in Real Ear methods. The REAT method was used to measure sound attenuation of earmuffs, while MIRE was used to determine changes in attenuation of earmuffs due to the use of other personal protective equipment. Results: The study showed reduction in attenuation of earmuffs due to the use of a full face mask up to 20 dB. Using a full face mask causes that attenuation of earmuffs in the low frequency range is close to zero. Reduction in attenuation due to the use of half masks for complete with particle filters (half masks is 3–15 dB. Simultaneous use of earmuffs and filtering half masks makes small changes in attenuation not exceeding 3 dB. Conclusions: The study showed that full face masks give the greatest reduction in attenuation of earmuffs. On the other hand, the least reduction is observed in the case of filtering half masks. There is a significant difference between the reduction in attenuation of earmuffs worn with half masks for complete with particle filters because they may be equipped with different kind of the head strap. Med Pr 2017;68(3:349–361

  19. Towards an Active Hearing Protection Device for Musicians =

    Science.gov (United States)

    Bernier, Antoine

    Professional musicians are oftentimes exposed to high levels of sound. Prolonged or severe exposure to high sound levels could lead to permanent hearing loss and compromise their career. The logical solution would be to wear hearing protection devices (HPDs) when appropriate. However, perceptual discomfort associated with wearing HPD can discourage their use by musicians. The perceptual discomfort is caused by two detrimental effects: the occlusion effect and the isolation effect. The occlusion effect is often reported as an augmented, unnatural and annoying perception of one's own voice or instrument mechanically coupled to the head when wearing HPDs. The isolation effect is the unnatural sensation of being isolated from a given sound environment and can be caused by wearing HPDs that do not compensate for psychoacoustical factors and therefore alter the wearer's auditory perception. Both effects are highly unfavorable to the musicians' auditory perception and compromise their capacity to perform to the best of their abilities for their audience. They are among the reasons most often reported by musicians to decide not to wear HPDs. This master's project presents the concept and first prototype of an active HPD for musicians that aims at solving the detrimental effects while protecting the musician's hearing. A solution for the occlusion effect is presented in the form of an earplug complemented with in-ear active noise control. Practical design issues and required trade-off are analyzed through a literature review and the implementation and characterization of an active occlusion effect reduction system, allowing reduction of the occlusion effect between 8.5 and 12 dB at 250 Hz. A solution for the isolation effect is presented in the form of an earplug complemented with digital signal processing capabilities. Factors that may cause the isolation effect are identified through a literature review and corresponding algorithms that aim at re-establishing the

  20. Usefulness of the protection motivation theory in explaining hearing protection device use among male industrial workers.

    Science.gov (United States)

    Melamed, S; Rabinowitz, S; Feiner, M; Weisberg, E; Ribak, J

    1996-05-01

    The present study examined the usefulness of personal variables: noise annoyance, and components of the protection motivation theory (R. W. Rogers, 1983) along with social-organizational factors in explaining hearing protection device (HPD) use among Israeli manufacturing workers. Participants were 281 men exposed to harmful noise levels for which routine HPD use is required by regulation. In practice, 3 HPD user groups were identified: nonusers (n = 38), occasional users (n = 125), and regular users (n = 118). HPD use was objectively verified. HPD use was primarily related to the personal variables but not to management pressure, coworker pressure, or family support. The most powerful predictors of HPD use were perceived self-efficacy (for long-term HPD use), perceived susceptibility (to hearing loss), and noise annoyance, together explaining 48% of the outcome variance. These findings have implications for interventions aimed at motivating workers to use HPDs regularly.

  1. Protective coatings for in-vessel fusion devices

    International Nuclear Information System (INIS)

    Brossa, F.

    1984-01-01

    Coatings of Al/Si, SAP (Sintered Aluminium Powder), Al 2 O 3 , TiC (low-Z material) and Ta have been developed for in-vessel component protection. Anodic oxidation, vapor depositions, reactive sputtering, chemical vapor deposition (CVD) and plasma spray have been the coating formation methods studied. AISI 316, 310, 304, Inconel 600 and Mo were adopted as base materials. the coatings were characterized in terms of composition, structure and connection with the supporting material. The behavior of coatings under H + , D + and He + irradiation in the energy range 100 eV-8 keV was tested and compared to the solid massive samples. TiC and Ta coatings were tested with thermal shock under power density pulses of 1 kW/cm 2 generated by an electron beam gun. Temperature-dependence of the erosion of TiC by vacuum arcs in a magnetic field was also studied. TiC coatings have low sputtering values, good resistance to arcing and a high chemical stability. TiC and Ta, CVD and plasma spray coatings are thermal-shock resistant. High thermal loads produce cracks but no spalling. Destruction occurred only after melting of the base material. The plasma spray coating method seems to be most appropriate for developing remote handling applications in fusion devices. (orig.)

  2. [Distal clavicle fracture].

    Science.gov (United States)

    Seppel, G; Lenich, A; Imhoff, A B

    2014-06-01

    Reposition and fixation of unstable distal clavicle fractures with a low profile locking plate (Acumed, Hempshire, UK) in conjunction with a button/suture augmentation cerclage (DogBone/FibreTape, Arthrex, Naples, FL, USA). Unstable fractures of the distal clavicle (Jäger and Breitner IIA) in adults. Unstable fractures of the distal clavicle (Jäger and Breitner IV) in children. Distal clavicle fractures (Jäger and Breitner I, IIB or III) with marked dislocation, injury of nerves and vessels, or high functional demand. Patients in poor general condition. Fractures of the distal clavicle (Jäger and Breitner I, IIB or III) without marked dislocation or vertical instability. Local soft-tissue infection. Combination procedure: Initially the lateral part of the clavicle is exposed by a 4 cm skin incision. After reduction of the fracture, stabilization is performed with a low profile locking distal clavicle plate. Using a special guiding device, a transclavicular-transcoracoidal hole is drilled under arthroscopic view. Additional vertical stabilization is arthroscopically achieved by shuttling the DogBone/FibreTape cerclage from the lateral portal cranially through the clavicular plate. The two ends of the FibreTape cerclage are brought cranially via adjacent holes of the locking plate while the DogBone button is placed under the coracoid process. Thus, plate bridging is achieved. Finally reduction is performed and the cerclage is secured by surgical knotting. Use of an arm sling for 6 weeks. Due to the fact that the described technique is a relatively new procedure, long-term results are lacking. In the short term, patients postoperatively report high subjective satisfaction without persistent pain.

  3. Staging workers' use of hearing protection devices: application of the transtheoretical model.

    Science.gov (United States)

    Raymond, Delbert M; Lusk, Sally L

    2006-04-01

    The threat of noise-induced hearing loss is a serious concern for many workers. This study explores use of the transtheoretical model as a framework for defining stages of workers' acceptance of hearing protection devices. A secondary analysis was performed using a cross-section of data from a randomized, controlled clinical trial of an intervention to increase use of hearing protection. Use of hearing protection devices was well distributed across the theorized stages of change. Chi-square analysis and analysis of variance revealed significant differences between stages for the variables studied. Discrete stages of hearing protection device use can be identified, laying the foundation for further work investigating use of the transtheoretical model for promoting hearing protection device use. The model can provide a framework for tailoring interventions and evaluating their effects. With further development of the transtheoretical model, nurses may be able to easily identify workers' readiness to use hearing protection devices and tailor training toward that goal.

  4. Study of the Effective Parameters on the Making Use of Protective Devices

    Directory of Open Access Journals (Sweden)

    Y Tabaraie

    2012-05-01

    Full Text Available

    Background and objectives

    Noise threats health of many groups of industrial workers and causes hearing loss. Use of personal protective device is the best control method to protect against hazardous conditions. Hence, this investigation was carried out to determine situation of using of protective devices and effective parameters on it, in Qom province workers community in 2006.

     

    Methods

    This research is descriptive-sectional study. Sample volume was designed 378 persons working in factories in Qom. First of all, list of Qom factories with noise pollution problems, were collected and 30 important factories among them were selected randomly. In the second stage, 378 persons were selected randomly from workers. The interest information was obtained by questionnaire and collected data were analyzed by SPSS software.

     

    Results

    The obtained results showed that, 83.6% of workers have been using ear protective devices. 296 of them, which were using ear protective devices, had an occupational hygienist in their workplaces. This research also showed that, 109 workers that used ear protective devices, had moderate knowledge level. Moreover, 82.5% of trained workers have used ear protective devices. The statistical analysis of the results showed that there were no significant relationship between use of ear protective devices and existence of occupational hygienist in workplace, knowledge and age of workers, worker’s antecedent, physical health of workers and kind of ear protective devices (p> 0.05. 

     

    Conclusion

    These results showed that among all considered parameters; only four parameters were effective in using ear protective devices; education of workers before employment, head workman and employer’s knowledge level, factories facilitation and kind of ear protective devices.

     

  5. Renal embolic protection devices improve blood flow after stenting for atherosclerotic renal artery stenosis.

    Science.gov (United States)

    Paul, Timir K; Lee, John H; White, Christopher J

    2012-11-15

    We sought to measure angiographic renal frame counts (RFC), as a quantitative angiographic assessment of renal blood flow, to evaluate microvascular compromise due to atheroembolism associated with RAS. Atheroembolism associated with renal artery stenting (RAS) has been implicated as a cause for worsening renal function following successful intervention. Use of a distal embolic protection device (EPD) during RAS has been shown to be safe with debris capture in a high percentage of cases. However, objective benefit for renal function with EPD has been difficult to demonstrate. A control group of 30 consecutive patients (33 kidneys) who underwent RAS without EPD were compared with 33 consecutive patients (33 kidneys) who underwent RAS with EPD using RFC measurement. The prestent and poststent mean RFC for the control group was 30.4 ± 12.1 vs. 23.7 ± 9.9 (P = 0.002) and for the EPD group it was 42.6 ± 12.6 vs. 28.3 ± 9.2 (P renal blood flow, manifested by a greater reduction of the RFC (Δ RFC) 14.2 ± 15.2 vs. 6.7 ± 11.7 (P = 0.03) compared with the control group. The use of an EPD was associated with a much larger improvement in renal blood flow (lower RFC) following RAS. This suggests that EPD's may be effective in preventing renal atheroembolic injury and that a controlled trial measuring the impact of EPD's on renal blood flow following RAS should be performed. Copyright © 2012 Wiley Periodicals, Inc.

  6. Safeguards of basic protection devices, high-protection devices, full-protection devices and school X-ray devices. Guideline for manufacturer and evaluating experts, rev. 1.0; Sicherheitsvorrichtungen von Basisschutzgeraeten, Hochschutzgeraeten, Vollschutzgeraeten und Schulroentgeneinrichtungen. Anforderungen fuer die Bauartpruefung nach der Roentgenverordnung. Leitfaden fuer Hersteller und Gutachter Rev. 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Dombrowski, Harald; Grottker, Ulrich; Pullner, Bjoern; Roettger, Annette; Zwiener, Roland

    2017-07-15

    This report describes the PTB requirements for engineered safeguards of basic-protection devices, high-protection devices, full-protection devices and school X-ray devices within the framework of type tests according to the German X-ray Ordinance. It contains detailed requirements for the hard- and software to ensure the required safety level. Especially manufacturers and evaluators of such X-ray tube assemblies are addressed.

  7. 30 CFR 77.600 - Trailing cables; short-circuit protection; disconnecting devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cables; short-circuit protection... AREAS OF UNDERGROUND COAL MINES Trailing Cables § 77.600 Trailing cables; short-circuit protection; disconnecting devices. Short-circuit protection for trailing cables shall be provided by an automatic circuit...

  8. The use of hearing protection devices by older adults during recreational noise exposure.

    Science.gov (United States)

    Nondahl, D M; Cruickshanks, K J; Dalton, D S; Klein, B E K; Klein, R; Tweed, T S; Wiley, T L

    2006-01-01

    A population-based study to assess the use of hearing protection devices by older adults during noisy recreational activities was performed. The population-based Epidemiology of Hearing Loss Study was designed to measure the prevalence of hearing loss in adults residing in Beaver Dam, Wisconsin. The use of hearing protection devices during noisy recreational activities was assessed by performing three examinations over a period of 10 years (1993-1995, no. of participants (n)=3753, aged 48-92 years; 1998-2000, n=2800, aged 53-97 years; 2003-2005, n=2395, aged 58-100 years). The recreational activities included hunting, target shooting, woodworking/carpentry, metalworking, driving loud recreational vehicles, and performing yard work using either power tools or a chain saw. The prevalence of using hearing protection devices during any of these activities increased with time (9.5%, 15.0%, and 19.9% at baseline, 5 years, and 10 years, respectively). However, the use of hearing protection devices remained low for most activities. Those under the age of 65 were twice as likely to use hearing protection devices during noisy activities than were older adults. Men, those with a hearing handicap, and those with significant tinnitus were more likely to use hearing protection devices. Smokers and the less educated were less likely to use hearing protection devices. The results demonstrated that many adults expose themselves to potentially damaging recreational noise, leaving them at risk for hearing loss.

  9. Graphene in NLO Devices for High Laser Energy Protection

    Science.gov (United States)

    2010-10-01

    manufacturing graphene in > tonlyr quantities suitable for industrial applications, has been working to advance the application base ofgJ1lphene. We have...Transfer A suspension of graphene in toluene was sent to the Army’s Tank- Automotive Research, Development, and Engineering Center (TARDEC) for evaluation in...protection efficiency. Therefore, a critical component for evaluation and use of graphene suspensions for laser protection is dispersion of the graphene

  10. Using Protection Layers for a 2-Photon Water Splitting Device

    DEFF Research Database (Denmark)

    Seger, Brian; Mei, Bastian Timo; Frydendal, Rasmus

    2015-01-01

    The 2-photon tandem device for photocatalytic water splitting has been theoretically shown to provide a higher efficiency than a single photon device(1). This increased efficiency can be achieved by having one material optimized to absorb high energy photons (large bandgap) and another material...... optimized to absorb low energy photons (small bandgap). To a large degree this approach has been hindered by corrosion issues. In this talk I will first discuss how our computational screening of 2,400 materials showed that very few materials can efficiently absorb light without corroding in water splitting...

  11. Awareness training and hearing protection devices: Current practices in the South African mining industry

    CSIR Research Space (South Africa)

    Edwards, A

    2012-09-01

    Full Text Available This presentation outlines the importance of awareness training of managers at all levels and miners regarding the importance of hearing protection devices and adequate knowledge, motivation and training to prevent hearing loss....

  12. Research and development to protect soldiers from landmines and improvised explosive devices

    CSIR Research Space (South Africa)

    Ahmed, R

    2015-10-01

    Full Text Available Landmines and Improvised Explosive Devices (IEDs) remain a major threat for military vehicles, their occupants and other assets. It is thus imperative that traditional methods of protection need to be adapted or new technologies developed....

  13. Clothing, equipment and devices for personnel protection: Its selection according to occupational risks

    International Nuclear Information System (INIS)

    1989-01-01

    This Venezuelan standard establishes the selection of the type of clothing, equipment and devices for personnel protection, to be used by workers according to the occupational risk they deal with, in order to avoid or to reduce the factors that can, directly or indirectly, affect their physical integrity. For the risks not contemplated in this norm, the selection of the type of clothing, equipment and devices for personnel protection, must be done following the corresponding international standard [es

  14. Evaluating Tree Protection Devices: Effects on Growth and Survival–First-Year Results

    Science.gov (United States)

    L. R. Costello; R. H. Schmidt; Gregory A. Giusti

    1991-01-01

    The protection of seedlings from animal browsing is critical for the survival and growth of many tree species. This is particularly true in wildland areas and arid areas (McAuliffe, 1986), and oftentimes in urban areas. A variety of techniques and devices have been used to protect seedlings, from using straw stubble to milk cartons to plastic or metal screens. Recently...

  15. Intercomparison of radiation protection protection devices in a high-energy stray neutron field. Part III: Instrument response

    Czech Academy of Sciences Publication Activity Database

    Silari, M.; Agosteo, S.; Beck, P.; Bedogni, R.; Cale, E.; Caresana, M.; Domingo, C.; Donadille, L.; Dubourg, N.; Esposito, A.; Fehrenbacher, G.; Fernández, F.; Ferrarini, M.; Fiechtner, A.; Fuchs, A.; García, M. J.; Golnik, N.; Gutermuth, F.; Khurana, S.; Klages, T.; Latocha, M.; Mares, V.; Mayer, S.; Radon, T.; Reithmeier, H.; Rollet, S.; Roos, H.; Rühm, W.; Sandri, S.; Schardt, D.; Simmer, G.; Spurný, František; Trompier, F.; Villa-Grasa, C.; Weitzenegger, E.; Wiegel, B.; Wielunski, M.; Wissmann, F.; Zechner, A.; Zielczyński, M.

    2009-01-01

    Roč. 44, 7-8 (2009), s. 673-691 ISSN 1350-4487 R&D Projects: GA AV ČR IAA100480902 Institutional research plan: CEZ:AV0Z10480505 Keywords : radiation protection devices * radiation field * detectors * dosemeters Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.973, year: 2009

  16. Implementation of Transformer Protection by Intelligent Electronic Device for Different Faults

    OpenAIRE

    Y V Aruna, Beena S

    2015-01-01

    Protection of power system equipments was traditionally done by using electromagnetic relay, static relays, and numerical relays. At present the microprocessor based relays are replacing the old Electromagnetic relays because of their high level accuracy and fast operation. RET670(Transformer protection relay ), an IED (INTELLIGENT ELECTRONIC DEVICE) provides fast and selective protection, monitoring, and control of all types of transformer. The configured IED is tested under diff...

  17. Corrosion and corrosion protection of support structures for offshore wind energy devices (OWEA)

    Energy Technology Data Exchange (ETDEWEB)

    Momber, A. [Muehlhan AG, Schlinckstrasse 3, D-21107 Hamburg (Germany)

    2011-05-15

    The paper provides a review about the corrosion and corrosion protection of offshore wind energy devices (OWEA). Firstly, special features resulting from location and operation of OWEA are being discussed. Secondly, types of corrosion and corrosion phenomena are summarized in a systematic way. Finally, practical solutions to the corrosion protection of OWEA, including steel allowances, cathodic protection and coatings and linings, are discussed. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. A Study on the technology of the Protective Device Application for the power Telecommunication Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B.K.; Lee, S.J.; Choi, H.Y. [Korea Electric Power Research Insitute, Taejeon (Korea, Republic of); Lee, B.H.; Jeon, D.K.; Lee, K.O.; Ahn, C.H.; Kim, S.O.; Kim, J.S. [Electrical Engineering and Science Research Center, Seoul (Korea, Republic of)

    1997-12-31

    In order to protect the power telecommunication system from surge by lightning or switching and ground potential rise, characteristics of surge are analyzed when surge strikes communication system. Surge generator which meets international standard was made and test of protective devices was carried out by using it. Counter measures against surge is established through the analysis of ground potential which varies with transient ground impedance. Also specification for installing protective devices was recommended, which is proper to apply to the field system. (author). 186 refs., 203 figs., 21 tabs.

  19. PLZT thermal/flash protective goggles: device concepts and constraints

    International Nuclear Information System (INIS)

    Cutchen, J.T.

    1979-01-01

    In 1975 Sandia Laboratories began the design and development of PLZT Goggles for the US Air Force to provide protection from temporary flashblindness and permanent retinal burns caused by the brilliant flash of nuclear explosions. The user requirements, system and physical constraints, and use/storage environments were all considered in arriving at the final design goals. When the program began, there was no industrial capability to manufacture large-aperture PLZT materials or bonded lens assemblies. The technology has been established from a laboratory baseline in a brief period, and operational testing and evaluation by the Air Force has been completed. The goggles, identified as the EEU-2/P,, are now in production

  20. An overcurrent protection device for neutral beam sources

    International Nuclear Information System (INIS)

    Praeg, W.F.

    1983-01-01

    Electrical loads connected to capacitance elements in high voltage direct current systems are protected from damage caused by capacitance discharge overcurrents by connecting a longitudinal inductor between the capacitance element and the load. The inductor comprises a bifilar winding wound about a magnetic core, which forms an incomplete magnetic circuit. A diode is connected across a portion of the bifilar winding. Most of the energy discharged from the capacitance element is stored in the inductor and then dissipated, away from the load, in an L-R circuit comprising the diode and the coil winding. Multiple high voltage circuits having capacitance elements may be connected to loads through bifilar windings all wound about the aforementioned magnetic core

  1. New supporting and protecting device for nuclear boilers

    International Nuclear Information System (INIS)

    Pierart, Robert.

    1980-01-01

    A rigid supporting device is described. It is intended for permanently connected equipment such as a nuclear reactor vessel and its steam generators. It consists of a double thick metal plate structure, the two parts of which are rigidly fixed together: 1/ The lower part is provided with a central body enveloping and supporting the vessel by means of pivots welded to it. These pivots are adjusted and slide in bearings integrated into the above mentioned structure, which is double skinned by an external body enveloping at least partially the water boxes of the steam generators and supporting the steam generators by adjusted pivots sliding in bearings integrated into this external body. The bottom parts of the central and external bodies are welded onto a thick metallic base. 2/ The upper part is partitioned by vertical extensions of the central body in such a way as to form a discharging reservoir in its central part. Lateral bodies on both sides envelope the steam generator tube bundles. The upper part of these lateral bodies are connected together by casings which act as stiffeners [fr

  2. Preventive protection device and method for bottom of reactor pressure vessel

    International Nuclear Information System (INIS)

    Hayashi, Eisaku; Kurosawa, Koichi; Furukawa, Hideyasu; Morinaka, Ren; Enomoto, Kunio; Otaka, Masahiro; Yoshikubo, Fujio; Chiba, Noboru; Sato, Kazunori.

    1995-01-01

    In a preventive protection device for improving stresses in reactor structural components by jetting highly pressurized water with cavitation bubbles from a jetting nozzle toward structural components in a reactor pressure vessel, a fixed structure to a CRD housing is provided with a rotational body attached to the structure, a multi joint arm and a jetting nozzle supported to the multi joint arm. The jetting nozzle is disposed at a position where the center of the jetting deviates from the center of the CRD housing. In addition, a monitoring camera is disposed for displaying the target for preventive protection. The state of stresses on a plurality of targets for preventive protection can be improved by the preventive protection device at a fixed position in the bottom of a reactor pressure vessel where housings stand densely, thereby enabling to attain the preventive protection operation easily and rapidly. (N.H.)

  3. Protection relay of phase-shifting device with thyristor switch for high voltage power transmission lines

    Science.gov (United States)

    Lachugin, V. F.; Panfilov, D. I.; Akhmetov, I. M.; Astashev, M. G.; Shevelev, A. V.

    2014-12-01

    Problems of functioning of differential current protection systems of phase shifting devices (PSD) with mechanically changed coefficient of transformation of shunt transformer are analyzed. Requirements for devices of protection of PSD with thyristor switch are formulated. Based on use of nonlinear models of series-wound and shunt transformers of PSD modes of operation of major protection during PSD, switching to zero load operation and to operation under load and during short circuit operation were studied for testing PSD with failures. Use of the principle of duplicating by devices of differential current protection (with realization of functions of breaking) of failures of separate pares of PSD with thyristor switch was substantiated. To ensure protection sensitivity to the shunt transformer winding short circuit, in particular, to a short circuit that is not implemented in the current differential protection for PSD with mechanical switch, the differential current protection reacting to the amount of primary ampere-turns of high-voltage and low-voltage winding of this transformer was designed. Studies have shown that the use of differential current cutoff instead of overcurrent protection for the shunt transformer wndings allows one to provide the sensitivity during thyristor failure with the formation of a short circuit. The results of simulation mode for the PSD with switch thyristor designed to be installed as switching point of Voskhod-Tatarskaya-Barabinsk 220 kV transmission line point out the efficiency of the developed solutions that ensure reliable functioning of the PSD.

  4. Novel material and structural design for large-scale marine protective devices

    International Nuclear Information System (INIS)

    Qiu, Ang; Lin, Wei; Ma, Yong; Zhao, Chengbi; Tang, Youhong

    2015-01-01

    Highlights: • Large-scale protective devices with different structural designs have been optimized. • Large-scale protective devices with novel material designs have been optimized. • Protective devices constructed of sandwich panels have the best anti-collision performance. • Protective devices with novel material design can reduce weight and construction cost. - Abstract: Large-scale protective devices must endure the impact of severe forces, large structural deformation, the increased stress and strain rate effects, and multiple coupling effects. In evaluation of the safety of conceptual design through simulation, several key parameters considered in this research are maximum impact force, energy dissipated by the impactor (e.g. a ship) and energy absorbed by the device and the impactor stroke. During impact, the main function of the ring beam structure is to resist and buffer the impact force between ship and bridge pile caps, which could guarantee that the magnitude of impact force meets the corresponding requirements. The means of improving anti-collision performance can be to increase the strength of the beam section or to exchange the steel material with novel fiber reinforced polymer laminates. The main function of the buoyancy tank is to absorb and transfer the ship’s kinetic energy through large plastic deformation, damage, or friction occurring within itself. The energy absorption effect can be improved by structure optimization or by the use of new sandwich panels. Structural and material optimization schemes are proposed on the basis of conceptual design in this research, and protective devices constructed of sandwich panels prove to have the best anti-collision performance

  5. Study of efficiency and current use of respiratory protective devices

    International Nuclear Information System (INIS)

    Linauskas, S.H.; Kalos, F.

    1984-12-01

    The efficiency of a helmet-type powered air-purifying respirator was studied in the work environment of an underground uranium mine. Workplace protection factors (WPF) were measured, using approximately 30-minute air sampling periods and repeated sampling throughout the work shifts for six miners during three shifts each. The WPF of the modified Racal AH-5 helmet was 17.8 (geometric mean) with new filters in the respirator; the WPF dropped to 5.3 when four-day-old filters were used. The WPF results were lognormally distributed. The test population appeared to be a homogeneous set: there was no significant difference in the mean WPFs of individual test subjects. The study could not resolve any effect of elapsed time within the work shift or of ambient Working Level on the WPF. The actual use levels and the problems associated with respirator use were studied at the same time, principally via a user survey. The respirators have a high level of acceptance among the user population of underground uranium miners and 72.5 percent of the 207 survey respondents stated six or more hours use with the visor in the correct 'down' position per shift

  6. Surge protective device response to steep front transient in low voltage circuit

    Energy Technology Data Exchange (ETDEWEB)

    Marcuz, J.; Binczak, S.; Bilbault, J.M. [Universite de Bourgogne, Dijon (France)], Emails: jerome.marcuz@ laposte.net, stbinc@u-bourgogne.fr, bilbault@u-bourgogne.fr; Girard, F. [ADEE Electronic, Pont de Pany (France)

    2007-07-01

    Surge propagation on cables of electrical or data lines leads to a major protection problem as the number of equipment based on solid-state circuits or microprocessors increases. Sub-microsecond components of real surge waveform has to be taken into account for a proper protection even in the case of surges caused by indirect lightning effects. The response of a model of transient voltage suppressor diode based surge protection device (SPD) to fast front transient is analytically studied, then compared to simulations, including the lines connected to the SPD and to the protected equipment. (author)

  7. Smart Electrochemical Energy Storage Devices with Self-Protection and Self-Adaptation Abilities.

    Science.gov (United States)

    Yang, Yun; Yu, Dandan; Wang, Hua; Guo, Lin

    2017-12-01

    Currently, with booming development and worldwide usage of rechargeable electrochemical energy storage devices, their safety issues, operation stability, service life, and user experience are garnering special attention. Smart and intelligent energy storage devices with self-protection and self-adaptation abilities aiming to address these challenges are being developed with great urgency. In this Progress Report, we highlight recent achievements in the field of smart energy storage systems that could early-detect incoming internal short circuits and self-protect against thermal runaway. Moreover, intelligent devices that are able to take actions and self-adapt in response to external mechanical disruption or deformation, i.e., exhibiting self-healing or shape-memory behaviors, are discussed. Finally, insights into the future development of smart rechargeable energy storage devices are provided. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Influence of stent design and use of protection devices on outcome of carotid artery stenting: a pooled analysis of individual patient data.

    Science.gov (United States)

    Wodarg, Fritz; Turner, Elisabeth L; Dobson, Joanna; Ringleb, Peter A; Mali, Willem P; Fraedrich, Gustav; Chatellier, Gilles; Bequemin, Jean-Pierre; Brown, Martin M; Algra, Ale; Mas, Jean-Louis; Jansen, Olav; Bonati, Leo H

    2018-04-19

    Carotid artery stenting is an alternative to endarterectomy for the treatment of symptomatic carotid stenosis but was associated with a higher risk of procedural stroke or death in randomized controlled trials (RCTs). Technical aspects of treatment may partly explain these results. The purpose of this analysis was to investigate the influence of technical aspects such as stent design or the use of protection devices, as well as clinical variables, on procedural risk. We pooled data of 1557 individual patients receiving stent treatment in three large RCTs comparing stenting versus endarterectomy for symptomatic carotid stenosis. The primary outcome event was any procedural stroke or death occurring within 30 days after stenting. Procedural stroke or death occurred significantly more often with the use of open-cell stents (61/595 patients, 10.3%) than with closed-cell stents (58/962 patients, 6.0%; RR 1.76; 95% CI 1.23 to 2.52; P=0.002). Procedural stroke or death occurred in 76/950 patients (8.0%) treated with protection devices (predominantly distal filters) and in 43/607 (7.1%) treated without protection devices (RR 1.10; 95% CI 0.71 to 1.70; P=0.67). Clinical variables predicting the primary outcome event were age, severity of the qualifying event, history of prior stroke, and level of disability at baseline. The effect of stent design remained similar after adjustment for these variables. In symptomatic carotid stenosis, the use of stents with a closed-cell design is independently associated with a lower risk of procedural stroke or death compared with open-cell stents. Filter-type protection devices do not appear to reduce procedural risk. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Reverse Distal Transverse Palmar Arch in Distal Digital Replantation.

    Science.gov (United States)

    Wei, Ching-Yueh; Orozco, Oscar; Vinagre, Gustavo; Shafarenko, Mark

    2017-11-01

    Refinements in microsurgery have made distal finger replantation an established technique with high success rates and good functional and aesthetic outcomes. However, it still represents a technically demanding procedure due to the small vessel caliber and frequent lack of vessel length, requiring the use of interpositional venous grafts in some instances. We describe a new technique for anastomosis in fingertip replantation, whereby the need for venous grafts is eliminated. Applying the reverse distal transverse palmar arch technique, 11 cases of distal digital replantation were performed between January 2011 and July 2016. The described procedure was used for arterial anastomosis in 10 cases and arteriovenous shunting for venous drainage in 1 case. A retrospective case review was conducted. The technical description and clinical outcome evaluations are presented. Ten of the 11 replanted digits survived, corresponding to an overall success rate of 91%. One replant failed due to venous insufficiency. Blood transfusions were not required for any of the patients. Follow-up (range, 1.5-5 months) revealed near-normal range of motion and good aesthetic results. All of the replanted digits developed protective sensation. The average length of hospital admission was 5 days. All patients were satisfied with the results and were able to return to their previous work. The use of the reverse distal transverse palmar arch is a novel and reliable technique in distal digital replantation when an increase in vessel length is required, allowing for a tension-free arterial repair without the need for vein grafts.

  10. Estimation of digital protection devices applicability on basis of multiple characterizing parameters

    Directory of Open Access Journals (Sweden)

    Dimitar Bogdanov

    2018-01-01

    Full Text Available The contemporary electrical power systems (EPS impose increased requirements for the functionality of the protection systems. The necessity of improved EPS stability is in some extent resulting of the increased integration of renewable sources of electrical energy. The future grid development gives perspective for connection of more converter based generations. The power electronic schemes and associated functional requirements impose necessity of high speed, sensitive, selective and reliable operation of the protection devices. These requirements have always been target of the protection equipment producers and grid operators. The electronic converting schemes specifics impose these requirements for the protection devices in more straightened way, as the converter connected generator may need to trip in shorter time than classical machine generator. In the article is presented a generalized overview of some of the characteristics of the digital “relay” protection devices, and approach for device selection is proposed. Investment planning may utilize such approach in order to have an optimal design from financial point of view.

  11. Electronic Systems for the Protection of Superconducting Devices in the LHC

    CERN Document Server

    Denz, R; Mess, K H

    2008-01-01

    The Large Hadron Collider LHC [1] incorporates an unprecedented amount of superconducting components: magnets, bus-bars, and current leads. Most of them require active protection in case of a transition from the superconducting to the resistive state, the so-called quench. The electronic systems ensuring the reliable quench detection and further protection of these devices have been developed and produced over the last years and are currently being put into operation

  12. Nonconformance in electromechanical output relays of microprocessor-based protection devices under actual operating conditions

    OpenAIRE

    Gurevich, Vladimir

    2006-01-01

    Microprocessor-based protection relays are gradually driving out traditional electromechanical and even electronic protection devices from virtually all fields of power and electrical engineering. In this paper, one of many problems of microprocessor-based relays is discussed: nonconformance of miniature electromechanical output relays under actual operation conditions: switching inductive loads (with tripping CB coils or lockout relay coils) at 220 VDC, and "dry" switching of some control ci...

  13. Gender and other factors associated with the use of hearing protection devices at work

    Directory of Open Access Journals (Sweden)

    Tatiane Costa Meira

    2015-01-01

    Full Text Available OBJECTIVE To analyze whether sociodemographic, occupational, and health-related data are associated with the use of hearing protection devices at work, according to gender.METHODS A cross-sectional study was conducted in 2006, using a random sample of 2,429 workers, aged between 18 and 65 years old, from residential sub-areas in Salvador, BA, Northeastern Brazil. Questionnaires were used to obtain sociodemographic, occupational, and health-related data. Workers who reported that they worked in places where they needed to shout in order to be heard were considered to be exposed to noise. Exposed workers were asked whether they used hearing protection devices, and if so, how frequently. Analyses were conducted according to gender, with estimates made about prevalence of the use of hearing protection devices, prevalence ratios, and their respective 95% confidence intervals.RESULTS Twelve percent (12.3% of study subjects reported that they were exposed to noise while working. Prevalence of the use of hearing protection devices was 59.3% for men and 21.4% for women. Men from higher socioeconomic levels (PR = 1.47; 95%CI 1.14;1.90 and who had previous audiometric tests (PR = 1.47; 95%CI 1.15;1.88 were more likely to use hearing protection devices. For women, greater perceived safety was associated with the use of protection devices (PR = 2.92; 95%CI 1.34;6.34. This perception was specifically related to the presence of supervisors committed to safety (PR = 2.09; 95%CI 1.04;4.21, the existence of clear rules to prevent workplace injuries (PR = 2.81; 95%CI 1.41;5.59, and whether they were informed about workplace safety (PR = 2.42; 95%CI 1.23;4.76.CONCLUSIONS There is a gender bias regarding the use of hearing protection devices that is less favorable to women. The use of such devices among women is positively influenced by their perception of a safe workplace, suggesting that gender should be considered as a factor in hearing conservation programs.

  14. Distal renal tubular acidosis

    Science.gov (United States)

    ... this disorder. Alternative Names Renal tubular acidosis - distal; Renal tubular acidosis type I; Type I RTA; RTA - distal; Classical RTA Images Kidney anatomy Kidney - blood and urine flow References Bose A, Monk RD, Bushinsky DA. Kidney ...

  15. Diffusion-weighted magnetic resonance imaging in carotid angioplasty and stenting with balloon embolic protection devices

    International Nuclear Information System (INIS)

    Asakura, Fumio; Kawaguchi, Kenji; Sakaida, Hiroshi; Toma, Naoki; Matsushima, Satoshi; Kuraishi, Keita; Tanemura, Hiroshi; Miura, Yoichi; Taki, Waro; Maeda, Masayuki

    2006-01-01

    We compared the results of two procedures to protect against distal embolism caused by embolic debris from carotid angioplasty with stent deployment (CAS) using diffusion-weighted magnetic resonance imaging (MRI). The study group comprised 39 men and 3 women (42 and 3 CAS procedures, respectively) with severe carotid stenosis (average age 70.0±6.6 years). During 20 CAS procedures the internal carotid artery was protected with a single balloon. A PercuSurge GuardWire was used for temporary occlusion. During 25 CAS procedures the internal and external carotid arteries were simultaneously temporarily occluded with a PercuSurge GuardWire and a Sentry balloon catheter, respectively. Diffusion-weighted MRI was performed 1 to 3 days after CAS. Data from 26 patients undergoing conventional angiography for diagnosis of cerebral ischemic disease, cerebral aneurysm or brain tumors were included as controls. Diffusion-weighted MRI after conventional diagnostic angiography showed ischemic spots in 3 of the 26 controls (11.5%). Ischemic spots were observed during 11 of 20 CAS procedures with the internal carotid artery protected with a single balloon (55.0%), and were observed during 9 of 25 CAS procedures with both the internal and external carotid arteries protected (36.0%). This difference was significant (P=0.0068). Ischemic lesions appeared not only ipsilateral to the carotid stenosis but also in the contralateral carotid artery (31.9%) and vertebrobasilar territory (25.3%). Better protection was obtained with simultaneous double occlusion of both the internal and external carotid artery than with single protection of the internal carotid artery during CAS. (orig.)

  16. Identification, investigation and analysis of end-of-wind protection devices for vertical and incline shafts.

    CSIR Research Space (South Africa)

    Ottermann, RW

    2000-12-01

    Full Text Available The occurrence and cause of overwind and underwind events in underground mining were investigated in conjunction with devices, which are at present being applied to prevent and control such incidents. Proposals for in-shaft systems to protect...

  17. Effects of Hearing Protection Device Attenuation on Unmanned Aerial Vehicle (UAV) Audio Signatures

    Science.gov (United States)

    2016-03-01

    UAV ) Audio Signatures by Melissa Bezandry, Adrienne Raglin, and John Noble Approved for public release; distribution...Research Laboratory Effects of Hearing Protection Device Attenuation on Unmanned Aerial Vehicle ( UAV ) Audio Signatures by Melissa Bezandry...Aerial Vehicle ( UAV ) Audio Signatures 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Melissa Bezandry

  18. Tests of microprocessor-based relay protection devices: Problems and solutions

    Directory of Open Access Journals (Sweden)

    Gurevich Vladimir

    2009-01-01

    Full Text Available Usually, the operational condition of relay protection devices is checked with specific settings used for the relay operation in a certain network point. In the author's opinion in order to verify the proper operation of complex multifunctional microprocessor-based protection devices (MPD at their inspection, start-up after repairs or during periodic tests there is no need to use the actual settings at which the relay is to be operated in a certain network's point. It should be tested for proper operation at several of its most critical preset characteristic points as well as in several preset characteristics constituting its most complicated (combined operation modes, including the dynamic operation modes with preset transition processes specific for standard power networks (not necessarily for a specific point. The proposed set of actions for the unification of software platforms of the modern, microprocessor-based relay protection test systems will enable examination of modern MPD in an absolutely new way. .

  19. A study on ship impacting a flexible crashworthy device for protecting bridge pier

    Directory of Open Access Journals (Sweden)

    Yang Liming

    2015-01-01

    Full Text Available As the accident of a vessel impacting a bridge pier will cause serious disaster, such as destroyed bridge, sinking ship and polluting environment, the technology and method to protect bridge pier from ship collision have been widely investigated recently. Due to the huge kinetic energy of large-tonnage ship and the short time duration in the collision, the studies involve impact mechanics. A developed flexible crashworthy device has been developed to protect bridges, which consists of an outer steel-periphery, an inner steel-periphery and the rubber coating SWRCs(soft elements installed between them. When the SWRC crashworthy device is installed, the collision duration under low impact force is prolonged due to its high compliance, which results in the ship having enough time to turn its navigation direction and most of the remainder kinetic energy being carried off by the turned away ship. Consequently, both impact forces on the ship and on the bridge pier decrease markedly. This is the key reason as to why the SWRC crashworthy device can avoid the destruction of both the bridge and the ship. Based on our results of theoretical studies and numerical simulations, the present paper will propose an experiment-adopted a real ship to impact a flexible crashworthy device. The collision test has been performed 12 times with different speed, carrying capacity, and impact angle of the ship. After the experiments, the ship, flexible crashworthy device and the pier are not damaged. The experiments show that the flexible crashworthy device can turn away the impact ship, so that the ship moves along the outer part of the device, which reduces the ship impact force on the bridge pier obviously. It not only protects bridges but also avoids the damage to ships.

  20. Web software for the control and management of radiation protection devices in the Cadarache site

    International Nuclear Information System (INIS)

    Beltritti, F.

    2010-01-01

    This series of slides presents how to use a new software dedicated to the management of the periodical controls that have to be performed on the equipment involved in radiation protection. This software is ready to be dispatched on the CEA site of Cadarache. This software gives information on: the device to be controlled, the controls that have to be performed, the procedures to follow to make the test, the equipment necessary for the test particularly the need for radioactive sources, the maintenance of the device, the previous measurements and in the end the device's conformity. An evaluation of the conformity of all the devices present in a building or an area or of a particular type can be easily obtained. (A.C.)

  1. MODELING OF POWER SYSTEMS AND TESTING OF RELAY PROTECTION DEVICES IN REAL AND MODEL TIME

    Directory of Open Access Journals (Sweden)

    I. V. Novash

    2017-01-01

    Full Text Available The methods of modelling of power system modes and of testing of relay protection devices with the aid the simulation complexes in real time and with the help of computer software systems that enables the simulation of virtual time scale are considered. Information input protection signals in the simulation of the virtual model time are being obtained in the computational experiment, whereas the tests of protective devices are carried out with the help of hardware and software test systems with the use of estimated input signals. Study of power system stability when modes of generating and consuming electrical equipment and conditions of devices of relay protection are being changed requires testing with the use of digital simulators in a mode of a closed loop. Herewith feedbacks between a model of the power system operating in a real time and external devices or their models must be determined (modelled. Modelling in real time and the analysis of international experience in the use of digital simulation power systems for real-time simulation (RTDS simulator have been fulfilled. Examples are given of the use of RTDS systems by foreign energy companies to test relay protection systems and control, to test the equipment and devices of automatic control, analysis of cyber security and evaluation of the operation of energy systems under different scenarios of occurrence of emergency situations. Some quantitative data on the distribution of RTDS in different countries and Russia are presented. It is noted that the leading energy universities of Russia use the real-time simulation not only to solve scientific and technical problems, but also to conduct training and laboratory classes on modelling of electric networks and anti-emergency automatic equipment with the students. In order to check serviceability of devices of relay protection without taking into account the reaction of the power system tests can be performed in an open loop mode with the

  2. Privacy Protection for Personal Health Device Communication and Healthcare Building Applications

    Directory of Open Access Journals (Sweden)

    Soon Seok Kim

    2014-01-01

    Full Text Available This paper proposes a new method for protecting patient privacy when communicating with a gateway which collects bioinformation through using personal health devices, a type of biosensor for telemedicine, at home and in other buildings. As the suggested method is designed to conform with ISO/IEEE 11073-20601, which is the international standard, interoperability with various health devices was considered. We believe it will be a highly valuable resource for dealing with basic data because it suggests an additional standard for security with the Continua Health Alliance or related international groups in the future.

  3. The solar ultraviolet B radiation protection provided by shading devices with regard to its diffuse component.

    Science.gov (United States)

    Kudish, Avraham I; Harari, Marco; Evseev, Efim G

    2011-10-01

    The composition of the incident solar global ultraviolet B (UVB) radiation with regard to its beam and diffuse radiation fractions is highly relevant with regard to outdoor sun protection. This is especially true with respect to sun protection during leisure-time outdoor sun exposure at the shore and pools, where people tend to escape the sun under shade trees or different types of shading devices, e.g., umbrellas, overhangs, etc., believing they offer protection from the erythemal solar radiation. The degree of sun protection offered by such devices is directly related to the composition of the solar global UVB radiation, i.e., its beam and diffuse fractions. The composition of the incident solar global UVB radiation can be determined by measuring the global UVB (using Solar Light Co. Inc., Model 501A UV-Biometer) and either of its components. The beam component of the UVB radiation was determined by measuring the normal incidence beam radiation using a prototype, tracking instrument consisting of a Solar Light Co. Inc. Model 501A UV-Biometer mounted on an Eppley Solar Tracker Model St-1. The horizontal beam component of the global UVB radiation was calculated from the measured normal incidence using a simple geometric correlation and the diffuse component is determined as the difference between global and horizontal beam radiations. Horizontal and vertical surfaces positioned under a horizontal overhang/sunshade or an umbrella are not fully protected from exposure to solar global UVB radiation. They can receive a significant fraction of the UVB radiation, depending on their location beneath the shading device, the umbrella radius and the albedo (reflectance) of the surrounding ground surface in the case of a vertical surface. Shading devices such as an umbrella or horizontal overhang/shade provide relief from the solar global radiation and do block the solar global UVB radiation to some extent; nevertheless, a significant fraction of the solar global UVB

  4. Plasma sprayed TiC coatings for first wall protection in fusion devices

    International Nuclear Information System (INIS)

    Groot, P.; Laan, J.G. van der; Laas, L.; Mack, M.; Dvorak, M.

    1989-01-01

    For protection of plasma facing components in nuclear fusion devices thick titanium carbide coatings are being developed. Coatings have been produced by plasma spraying at atmospheric pressure (APS) and low pressure (LPPS) and analyzed with respect to microstructure and chemical composition. Thermo-mechanical evaluation has been performed by applying short pulse laser heat flux tests. The influence of coating thickness and porosity on the resistance to spalling by thermal shocks appears to be more important than aspects of chemical composition. (author)

  5. Balance between Privacy Protecting and Selling User Data of Wearable Devices

    OpenAIRE

    Huang, Kuang-Chiu; Hsu, Jung-Fang

    2017-01-01

    Smart bracelets are capable of identifying individual data, which can synchronize the step count, mileage, calorie consumption, heart rate, sleeping data and even the pictures users uploaded with the APP. This feature is so convenient on one hand but makes us lose control of our privacy on the other hand. With poor privacy protection mechanism embedded in these wearable devices that hackers can easily invade and steal user data. In addition, most smart bracelet companies have not made a clear...

  6. Fish protection at steam-electric power plants: alternative screening devices

    International Nuclear Information System (INIS)

    Cannon, J.B.

    1978-01-01

    Since the enactment of the Federal Water Pollution Control Act Amendments of 1972, very few innovations have surfaced that advance the state of intake technology for fish protection at steam-electric power plants. After careful examination of basic hydrology, hydraulics, and ecology of the source water body is completed and after a suitable location for the intake is established, the design process reduces to the development of proper screening techniques and to the provision of a means of preventing resident and migratory species from entering the intake structure. As a result of this design process, three basic fish protection concepts have evolved: fish deterrence, fish collection and removal, and fish diversion. Intake screening devices that protect fish are discussed

  7. Cerebral protection devices for use during carotid artery angioplasty with stenting: a health technology assessment.

    Science.gov (United States)

    Menon, Devidas; Stafinski, Tania

    2006-01-01

    This study sought to examine the safety, efficacy, and economic implications of the use of cerebral protection devices during carotid artery angioplasty and stenting (CAS) in high-risk patients with severe carotid artery disease (CAD). A comprehensive search for peer- and non-peer-reviewed studies that compared carotid endarterectomy (CEA) or CAS without cerebral protection to CAS with cerebral protection and appeared in the English language literature between January 1990 and January 2005 was completed. Information from studies identified was extracted using a common data abstraction form and then critically appraised against published quality assessment criteria. Of the eight studies found, six provided information on technical or procedural success rates, with values ranging from 95.6 percent to 100 percent. Three of the four studies comparing groups of patients who received CAS with cerebral protection with those who received only CAS reported a non-statistically significantly higher 30-day incidence of death and stroke (major or minor) in the latter group. None of the three studies comparing CAS with cerebral protection to CEA demonstrated a statistically significant difference in the 30-day incidence of death, major stroke, or myocardial infarction between treatment groups. No economic analyses were found. In high-risk patients with severe CAD, the evidence suggests that CAS with cerebral protection may offer a safe and efficacious alternative to CEA, reducing the risk of embolic peri-procedural complications associated with CAS to acceptable levels.

  8. Fish-protection devices at unscreened water diversions can reduce entrainment: evidence from behavioural laboratory investigations

    Science.gov (United States)

    Poletto, Jamilynn B.; Cocherell, Dennis E.; Mussen, Timothy D.; Ercan, Ali; Bandeh, Hossein; Kavvas, M. Levent; Cech, Joseph J.; Fangue, Nann A.

    2015-01-01

    Diversion (i.e. extraction) of water from rivers and estuaries can potentially affect native wildlife populations if operation is not carefully managed. For example, open, unmodified water diversions can act as a source of injury or mortality to resident or migratory fishes from entrainment and impingement, and can cause habitat degradation and fragmentation. Fish-protection devices, such as exclusion screens, louvres or sensory deterrents, can physically or behaviourally deter fish from approaching or being entrained into water diversions. However, empirical assessment of their efficacy is often lacking or is investigated only for particular economically or culturally important fishes, such as salmonids. The Southern population of anadromous green sturgeon (Acipenser medirostris) is listed as threatened in California, and there is a high density of water diversions located within their native range (the Sacramento–San Joaquin watershed). Coupled with their unique physiology and behaviour compared with many other fishes native to California, the green sturgeon is susceptible to entrainment into diversions and is an ideal species with which to study the efficacy of mitigation techniques. Therefore, we investigated juvenile green sturgeon (188–202 days post-hatch) in the presence of several fish-protection devices to assess behaviour and entrainment risk. Using a large experimental flume (∼500 kl), we found that compared with an open diversion pipe (control), the addition of a trash-rack box, louvre box, or perforated cylinder on the pipe inlet all significantly reduced the proportion of fish that were entrained through the pipe (P = 0.03, P = 0.028, and P = 0.028, respectively). Likewise, these devices decreased entrainment risk during a single movement past the pipe by between 60 and 96%. These fish-protection devices should decrease the risk of fish entrainment during water-diversion activities. PMID:27293725

  9. Distal digital replantation.

    Science.gov (United States)

    Jazayeri, Leila; Klausner, Jill Q; Chang, James

    2013-11-01

    Hand surgeons have been hesitant to perform distal digital replantation because of the technical challenges and the perception of a high cost-to-benefit ratio. Recent studies, however, have shown high survival rates and excellent functional and aesthetic results, providing renewed enthusiasm for distal replantation. The authors reviewed the literature and summarize key points regarding the surgical treatment, perioperative care, and outcomes of distal digital replantation. They describe specific techniques and considerations for surgical repair in each of four distal zones as described by Sebastin and Chung. Zone 1A replantation involves an artery-only anastomosis of a longitudinal pulp artery. Venous anastomosis first becomes possible in zone 1B. Zone 1C involves periarticular amputations where arthrodesis of the distal interphalangeal joint is usually indicated. Repair of the artery, vein, and nerve is technically optimal in zone 1D, where venous anastomosis should be performed. Overall, survival rates for distal digital replantation are similar to those reported for more proximal replantation. The literature reports good outcomes regarding nail salvage, fingertip sensibility, and range of motion, with restoration of length and aesthetic appearance. Distal replantation performed at institutions that specialize in microsurgery and specifically tailored to the level of injury is associated with good survival, function, and patient satisfaction and superior aesthetic outcome. More prospective data are needed to evaluate the cost of treatment, psychological outcomes, and functional outcomes of distal replantation compared with revision amputation.

  10. Device for protecting the containment vessel dome of a nuclear reactor

    International Nuclear Information System (INIS)

    Allain, A.; Filloleau, E.; Mulot, P.

    1976-01-01

    A device is disclosed for protecting the dome of a nuclear reactor containment vessel against the upward displacement of the concrete shield slab of said reactor and the resultant effects of tilting of an equipment unit mounted on the shield slab at the periphery of said slab, wherein said device comprises: (1) means for separating the equipment unit into two sections consisting of an upper section and a lower section, said lower section being rigidly fixed to said shield slab and said means being actuated by the upward displacement of said slab, (2) a system for vertical rectilinear guiding of said upper section within the containment vessel, and (3) rigid mechanical components which provide a coupling between the aforesaid upper and lower sections of the equipment unit and exert on said upper section under the action of the tilting motion of said lower section a thrust which causes the upward displacement of said upper section

  11. A simple device to protect against osteoradionecrosis induced by interstitial irradiation

    International Nuclear Information System (INIS)

    Levendag, P.C.; Visch, L.L.; Driver, N.

    1990-01-01

    The incidence of osteoradionecrosis has declined since the introduction of preventive oral hygiene programs and meticulous dental evaluations before and after irradiation. Nevertheless, radiation dose per se still remains an important factor in osteoradionecrosis. Interstitial radiation has received much attention in the past decade since the use of flexible afterloading systems. It has become common practice in large oncology centers to implant radiation carriers in bulky tumor in the oral cavity and/or oropharynx. For interstitial radiation, with or without external radiation, minimal tumor doses are often cited to be more than 70 Gy. Unfortunately, if the mandible receives more than 70 Gy, it is at risk for the development of osteoradionecrosis. Therefore a simple protective lead device has been designed for routine use in brachytherapy in oral cavity tumors to reduce the dose to the mandible. This device will diminish the potential risk of osteoradionecrosis development

  12. Research on Experiment of Islanding Protection Device of Grid-connected Photovoltaic System Based on RTDS

    Science.gov (United States)

    Zhou, Ning; Yang, Jia; Cheng, Zheng; Chen, Bo; Su, Yong Chun; Shu, Zhan; Zou, Jin

    2017-06-01

    Solar photovoltaic power generation is the power generation using solar cell module converting sunlight into DC electric energy. In the paper an equivalent model of solar photovoltaic power generation system is built in RTDS. The main circuit structure of the two-stage PV grid-connected system consists of the DC-DC, DC-AC circuit. The MPPT (Maximum Power Point Tracking) control of the PV array is controlled by adjusting the duty ratio of the DC-DC circuit. The proposed control strategy of constant voltage/constant reactive power (V/Q) control is successfully implemented grid-connected control of the inverter when grid-connected operation. The closed-loop experiment of islanding protection device of photovoltaic power plant on RTDS, verifies the correctness of the simulation model, and the experimental verification can be applied to this type of device.

  13. Related factors to workers' use of hearing protection device in knitting & ppinning factories of Yazd city based on Protection Motivation Theory

    Directory of Open Access Journals (Sweden)

    A. Barkhordi

    2009-10-01

    Full Text Available Background and aimsNoise-Induced Hearing Loss (NIHL is an important occupational disorder. High percentage of workers in occupational environments did not use the hearing protection device against harmful noise. This study was carried out to study factors related to workers' use of Hearing protection Device in Knitting & spinning factories of Yazd city based on protection motivation theory.MethodsIn this cross-sectional analytical study 280 workers of the knitting & spinning factories of Yazd City who exposed to harmful noise (over 85dB selected among the three factories by cluster sampling. The data gathered via exclusive interviews with selected workers  using the questionnaire designed based on protection motivation theory and were analyzedResults42/5 percent of workers permanently used hearing protection devices, and 20/7 percent of workers never use.There was a significant correlation between the age of workers and the mean score components of PMT; perceived severity, perceived vulnerability, perceived response efficacy and protection motivation. There was also a significant correlation between the work experience and the mean score of PMT factors; perceived severity, perceived response efficacy and perceived vulnerability. Also there was a significant correlation between workers' education level and the mean score of perceived response efficacy and there was a significant correlation between protection motivation and the mean score components of PMT; perceived vulnerability, perceived self-efficacy, perceived response efficacy, perceived costs and behaviorConclusionRegarding the significant correlations between the more constructs of PMT and protection motivation of workers for using hearing protective device, designing educational program based on PMT to increase hearing protection devices usage among workers is recommended.

  14. Fire protection devices in the controlled region of GKN nuclear power station

    International Nuclear Information System (INIS)

    Bernhardt, S.; Grauf, E.

    1976-01-01

    In the GKN nuclear power station ('Neckar reactor'), an 805 MW PWR reactor whose start-up is scheduled for the near future, fire protection measures have been realized that go far beyond those realized in other German nuclear power stations until now. One of the main reasons is that the authorities have been sensibilized by a fire in the refuelling cavity during construction and by the Browns Ferry fire and are therefore extremely thorough in their examination. Further subsections have been added to the fire prevention sections in order to provide better quenching devices for potential fire sites. (orig./AK) [de

  15. Security Hi-tech Individual Extra-light Device Mask: a new protection for [soccer] players.

    Science.gov (United States)

    Cascone, Piero; Petrucci, Bernardino; Ramieri, Valerio; Marianetti, Titto Matteo; TitoMatteo, Marianetti

    2008-05-01

    Among professional [soccer] players, a relevant incidence of maxillofacial trauma has been reported. The main challenge in these particular patients is to give them the possibility of a very short convalescence period and to make possible their agonistic activity as soon as possible. The authors here present an innovative technique to realize this--the Security Hi-tech Individual Extra-Light Device Mask, a customizable protective shield based on the player's face cast. A completely customized mask was forged over the player's face cast to protect the injured area. This mask shortens convalescence period, and due to its realization, it is comfortable and easy fitting, thus allowing the player to perform at a professional level in his sport activity in the shortest time possible.

  16. On-field evaluation of operator lens protective devices in interventional radiology

    International Nuclear Information System (INIS)

    Strocchi, S.; Chiaravalli, A.; Veronese, I.; Novario, R.

    2016-01-01

    The recent publication of the Euratom Directive 2013/59, adopting the reduction of eye lens dose limits from 150 to 20 mSv y"-"1, calls for the development of new tools and methodologies for evaluating the eye lens dose absorbed by the medical staff involved in interventional radiology practices. Moreover, the effectiveness of the protective devices, like leaded glasses, which can be employed for radiation protection purposes, must be tested under typical exposure scenarios. In this work, eye lens dose measurements were carried out on an anthropomorphic phantom simulating a physician bound to perform standard interventional neuroradiology angiographic procedures. The correlation between eye lens doses, in terms of Hp(0.07), and the equivalent dose [again in terms of Hp(0.07)] monthly measured with thermoluminescent dosemeters placed above the lead apron at the chest level was studied, in the presence and in the absence of different types of leaded glasses. (authors)

  17. Improvement of the protection devices for JT-60U LHRF antenna system

    International Nuclear Information System (INIS)

    Suzuki, Sadaaki; Seki, Masami; Shinozaki, Shinichi; Sato, Fumiaki; Hiranai, Shinichi; Hasegawa, Koichi; Moriyama, Shinichi; Ishii, Kazuhiro

    2007-09-01

    In the experiments featuring lower hybrid range of frequency (LHRF) system in JT-60U, carbon grills were attached to the plasma-facing part of the antenna in order to avoid the damage by the excessive heat load from the plasma. However some electric discharge traces were found there in the observation after the experiments. To avoid such discharges, improvements of the arc detector and the protection interlock by visible picture detection were tackled. In the arc detector, the amplification circuit was improved in order to obtain shorter response time and higher resolution of optical detection. Moreover, in visible picture detection, a new function of RF-on/off control utilizing PC image processing was added to distinguish the light of the arc from one of the plasma. This report summarizes improvement of the protection interlock device in a LHRF heating system. (author)

  18. Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

    International Nuclear Information System (INIS)

    D’Ercole, Loredana; Quaretti, Pietro; Cionfoli, Nicola; Klersy, Catherine; Bocchiola, Milena; Rodolico, Giuseppe; Azzaretti, Andrea; Lisciandro, Francesco; Cascella, Tommaso; Zappoli Thyrion, Federico

    2013-01-01

    To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 ± 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 ± 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 ± 0.42 Gy) were FR ) were 269 Gy cm 2 , 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1–102.7, p FR overexposures (OR 10.8, 95 % CI 1.1–109.5, p FR overexposure (OR 2.8, 95 % CI 1.1–7.4, p = 0.040). At multivariable analysis, stenosis ≥ 90 % (OR 2.8, 95 % CI 1.1–7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1–109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

  19. Design And Development Of An Automatic Single Phase Protective Device Using Ssr

    Directory of Open Access Journals (Sweden)

    Michael E.

    2017-10-01

    Full Text Available Since the discovery of energy safety has been a paramount subject matter. This we can see in todays electrical systems where protective devices such as fuse and circuit breakers are used to prevent fire hazards resulting from overload overvoltage and short circuits. However with all the revolution in technology these options may be considered less smart since the fuse made with wire strands calculated for specific current capacity faults permanently when the specified current rating is exceeded. While the circuit breaker which is made up of mechanical switch fails as a result of carbon forming and the wearing away of the contacts because of arcing. As a means of improvement this paper presents the design and development of an automatic single phase protective device using solid state relay SSR. This study is to ensure automatic cut off from power supply in cases of overvoltage above 240 V AC or when overload and short circuit current above 8amps is detected without permanent damage of a fuse placed along current path. Also the design will ensure that there is an automatic close circuit whenever the trigger switch is momentary switch is closed. The system is achieved via the use of PIC micro-controller current sensor and other discrete components. The system is tested and works well inhibiting the frequent faulting of fuses. It also helps to prevent hazard as a result of overvoltage overload and short circuit and ensures a close circuit when the trigger switch is closed.

  20. A New Orthodontic Appliance with a Mini Screw for Upper Molar Distalization.

    Science.gov (United States)

    Ozkalayci, Nurhat; Yetmez, Mehmet

    2016-01-01

    The aim of this study is to present a new upper molar distalization appliance called Cise distalizer designed as intraoral device supported with orthodontic mini screw for upper permanent molar distalization. The new appliance consists of eight main components. In order to understand the optimum force level, the appliance under static loading is tested by using strain gage measurement techniques. Results show that one of the open coils produces approximately 300 gr distalization force. Cise distalizer can provide totally 600 gr distalization force. This range of force level is enough for distalization of upper first and second molar teeth.

  1. A New Orthodontic Appliance with a Mini Screw for Upper Molar Distalization

    Directory of Open Access Journals (Sweden)

    Nurhat Ozkalayci

    2016-01-01

    Full Text Available The aim of this study is to present a new upper molar distalization appliance called Cise distalizer designed as intraoral device supported with orthodontic mini screw for upper permanent molar distalization. The new appliance consists of eight main components. In order to understand the optimum force level, the appliance under static loading is tested by using strain gage measurement techniques. Results show that one of the open coils produces approximately 300 gr distalization force. Cise distalizer can provide totally 600 gr distalization force. This range of force level is enough for distalization of upper first and second molar teeth.

  2. Absorbed doses by a technician, with and without (simulating) use of protection devices, in bone scintigraphy examination

    International Nuclear Information System (INIS)

    Jesus Lopes Filho, F. de; Antonio Filho, J.; Colaco, W.; Silveira, S.V. da

    1992-01-01

    The relation between the whole-body dose and the dose localized in body pants of a technician work in nuclear medicine was investigated by dosimetric films and thermoluminescent dosemeters. The investigation was made with and without a suitable protection devices. The results were discussed by a radiological protection view. (C.G.C.)

  3. New challenge for the radiation protection: devices for the radioactivity dispersion

    International Nuclear Information System (INIS)

    Mora, J. C.; Robles, B.; Cancio, C.

    2006-01-01

    In recent years the terrorist attacks produced in several countries have changed the mind of the security experts. This has also included the Radiation Protection aspects. Newly considered features have required the update of emergency response and preparedness, ad well as a greater emphasis on security. Within the Radiation Protection field has been introduced the radiological and nuclear terrorism definition. almost every organism and research centre involved in Radiation Protection is nowadays working on. The possible terrorist attack scenarios have already been defined and the use of an explosive to disperse radioactive material, known as a Radiation Dispersion Devices (RDD), has been specified as the most probable one. Studies to mitigate against the chance of attack and to mitigate the consequences of any attack with a RDD are complex, due to the innovation that introduce. This leads to a need to take some immediate preventative actions and to carry out additional R and D efforts. This document presents some considerations on the possible RDD design and behaviour in order to prevent and prepare against a possible attack. (Author) 17 refs

  4. The use of hearing protection devices with approach risk perception of noise induced hearing loss in several manufacturing industry

    Directory of Open Access Journals (Sweden)

    Behzad Fouladi Deahghi

    2015-06-01

    Full Text Available Background & Objective : Noise is a widespread physical agent and although is a most risk factors in workplaces that workers of health to exposed. Thus, different actions is done for reduce exposure to it in work places, which one of them is use of hearing protection devices. The use of hearing protection devices with approach risk perception of noise induced hearing loss in several manufacturing industry Method: This study was Cross-sectional study and done in five industrial unit with a sound pressure level more of 85 dB-A with the participation of 340 workers. To collect data , individual risk perception and self-investigator questionnaires were used. After collecting data, statistical analysis including Cronbach's alpha and regression were used to analyze the data. Results : Range use of hearing protection devices during shifts work by workers, respectively equal to: 50.4% sometimes, 31.58% never and 18.2% at all times. Also, results indicate significant differences between individual differences and hearing protection devices. Conclusion : Results of this study showed that individual risk perception as an important factor, can do a significant role in predicting the behavior of personals in the use of hearing protection devices, which should be considered in any design and implementation of hearing protection program.

  5. Protecting Touch: Authenticated App-To-Server Channels for Mobile Devices Using NFC Tags

    Directory of Open Access Journals (Sweden)

    Fernando Kaway Carvalho Ota

    2017-07-01

    Full Text Available Traditional authentication methods (e.g., password, PIN often do not scale well to the context of mobile devices in terms of security and usability. However, the adoption of Near Field Communication (NFC on a broad range of smartphones enables the use of NFC-enabled tokens as an additional authentication factor. This additional factor can help to improve the security, as well as usability of mobile apps. In this paper, we evaluate the use of different types of existing NFC tags as tokens for establishing authenticated secure sessions between smartphone apps and web services. Based on this evaluation, we present two concepts for a user-friendly secure authentication mechanism for mobile apps, the Protecting Touch (PT architectures. These two architectures are designed to be implemented with either end of the spectrum of inexpensive and widely-available NFC tags while maintaining a reasonable trade-off between security, availability and cost.

  6. Investigation of Vehicle Rear Under Run Protection Device (RUPD) Using Aluminium Foam

    Science.gov (United States)

    Nagaraj Goud, B.; pachori, Avinash

    2017-08-01

    Whenever the passenger cars meet with accidents with the heavy duty truck from rear, it will tend to penetrate under the truck bed called truck trailer under-ride crash. This is responsible for the thousands of accidents, causing severe injuries and spot death. This is mostly due to the lack of effective guarding system. The Present paper gives an importance on energy absorption mechanism of a Rear under Run Protection Device (RUPD) under crash effect of the truck. The aim of the study is to replace Steel RUPD with aluminum foam, which promises an improvement of vehicle crashworthiness as well as to reduce weight of the vehicle. The aluminum foam is selected due to the high specific strength and specific stiffness. This inborn character makes it a promising candidate in the modern lightweight structures in the automotive engineering which can contribute to the improvement of mileage in addition to safety of the occupants.

  7. TREATMENT OF INTERNAL CAROTID ARTERY OCCLUSION USING PROXIMAL CEREBRAL PROTECTION DEVICE AND ITS EFFECT ON THE BLOOD PRESSURE DYNAMICS. CLINICAL CASE

    Directory of Open Access Journals (Sweden)

    F. В. Shukurov

    2018-01-01

    Full Text Available In 2016, according to the Ministry of Health of the Russian Federation, about 200 thousand people died from stroke. Strokes are considered as the main cause of disability of the population, causing huge economic damage to the country. One of the most common causes of ischemic stroke is atherosclerosis of the branches of the aortic arch. The most common localization of atherosclerotic plaques is the extracranial section of the carotid arteries – bifurcation and ostium of the common carotid artery and the internal carotid artery. Recanalization of occlusion of the internal carotid artery until recently was an insoluble task for interventional surgery due to the high risk of distal embolization. The invention and use of the proximal cerebral protection device, which ensure the complete cessation of blood flow, has changed the situation. Effect of carotid revascularization on arterial hypertension, due to the effect on the baroreceptors of the carotid plexus by balloon angioplasty, which leads to a reflex decrease in arterial pressure, is an additional advantage of the endovascular technique in some cases. This effect requires further study. One also needs to pay careful attention to the diagnosis and imaging of carotid artery lesions before procedure. This clinical case is the illustration that an adequate assessment of the risk factors for intraoperative complications allows to achieve maximum results of endovascular treatment.

  8. Quality control devices for intraoperative gamma probes: physical, technical and radiation protection aspects

    International Nuclear Information System (INIS)

    Varela, C.; Diaz, M.; Salvador, F.J.; Hernandez, M.; Jimenez, P.

    2008-01-01

    Now a day, radio guided surgery -a novelty in Nuclear Medicine- is increasingly used. The clinical efficiency of these procedures requires the existence of well-trained professionals and implementation of quality assurance programs. It is essential for achieving the main objective, which is an effective and safe surgical procedure, a reliable performance of the detection device. Probes' parameters must remain within the acceptance limits, so they should be checked periodically. NEMA Standards Publication NU 3-2004 'Performance Measurement and Quality Control Guidelines for Non-Imaging Intraoperative Gamma Probes' recommends 13 tests; although only 3 of them -sensibility in air, visual inspection and power source check- are considered as steadiness tests. Space resolution in a scatter medium is also a test that needs to be carried out. These tests are considerably complex since open radioactive sources are used into a liquid medium in most of the procedures. The immersion of the probe and of the radioactive sources in each case represents both risks of radioactive contamination, and of damages to the equipment. On the other hand, tests in air demand a good reproducibility. Since they are recommended be carried out before any surgery procedure, they also should be easy and quick. This paper presents 3 devices with its accessories for acceptance and quality control tests of intraoperative gamma probes. They were designed and built taking into consideration important aspects of radiological protection to handle the calibration sources and probes, both in air and into a scatter medium. These devices are designed to fit any kind of probe. Regulatory bodies as part of their instrument audits can also use them. (author)

  9. Burst protection device for largely cylindrical steam raising units, preferably of pressurized water nuclear power stations

    International Nuclear Information System (INIS)

    Mutzl, J.

    1978-01-01

    This burst protection device controls forces to be expected in an accident by resolving them into axial (vertical) and radial (horizontal) components, which are taken by a large number of elements stressed in tension. The steam raising unit is surrounded by a containment, but remains easily accessible. The containment consists of a steel jacket, lid and floor. Several cylindrical sections above one another form the steel jacket, which surrounds the steam raising unit with an intermediate insulating layer of concrete. The insulating concrete cylinder is of several times the thickness of the steel jacket, and also consists of cylindrical sections. An outer supporting ring for the lid and floor of the containment have outside diameters which project beyond the jacket. Prestressed circumferential vertical tension ropes between the supporting ring and floor take any additional tensional forces. The lid is domed with downward curvature towards the upper boiler dome. Internal bursting forces produce compressive stresses in the lid, which thus pass along its outside diameter into the surrounding ring. The lid, which is devided along one diameter, makes dismantling and access to the boiler easy even with a central steam pipe going upwards. The floor of the burst protection is also the floor of the steam raising unit. It is of several times the thickness of the tube floor, which, with its spacing above the floor forms the usual inlet and outlet space for the reactor cooling water. The main coolant pump installed there is driven by an external motor through a floor penetration. (HP) [de

  10. Weibull aging models for the single protective channel unavailability analysis by the device of stages

    International Nuclear Information System (INIS)

    Nunes, M.E.C.; Noriega, H.C.; Melo, P.F.F.

    1997-01-01

    Among the features to take into account in the unavailability analysis of protective channels, there is one that plays a dominant role - that of considering the equipment aging. In this sense, the exponential failure model is not adequate, since some transition rates are no more constant. As a consequence, Markovian models cannot be used anymore. As an alternative, one may use the device of stages that allows for transforming a Non Markovian model into an equivalent Markovian one by insertion of a fictitious states set, called stages. For a given time-dependent transition rate, its failure density is analysed as to the best combination of exponential distributions and then the moments of the original distribution and those of the combination are matched to estimate the necessary parameters. In this paper, the aging of the protective channel is supposed to follow Weibull distributions. Typical means and variances for the times to failure are considered and combinations of stages are checked. Initial conditions features are discussed in connection with states that are fictitious and to check the validity of the developed models. Alternative solutions by the discretization of the failure rates are generated. The results obtained agree quite well. (author). 7 refs., 6 figs

  11. Gender differences in use of hearing protection devices among farm operators

    Directory of Open Access Journals (Sweden)

    Marjorie C McCullagh

    2016-01-01

    Full Text Available Purpose: Although farm operators have frequent exposure to hazardous noise and high rates of noise-induced hearing loss, they have low use of hearing protection devices (HPDs. Women represent about one-third of farm operators, and their numbers are climbing. However, among published studies examining use of HPDs in this worker group, none have examined gender-related differences. The purpose of this study was to examine gender-related differences in use of hearing protection and related predictors among farm operators. Materials and Methods: Data previously collected at farm shows and by telephone were analyzed using t-tests and generalized linear model with zero inflated negative binomial (ZINB distribution. Findings: The difference in rate of hearing protector use between men and women farm operators was not significant. There was no difference between men and women in most hearing protector-related attitudes and beliefs. Conclusion: Although men and women farm operators had similar rates of use of hearing protectors when working in high-noise environments, attitudes about HPD use differed. Specifically, interpersonal role modeling was a predictor of HPD use among women, but not for men. This difference suggests that while farm operators of both genders may benefit from interventions designed to reduce barriers to HPD use (e.g., difficulty communicating with co-workers and hearing warning sounds, farm women have unique needs in relation to cognitive-perceptual factors that predict HPD use. Women farm operators may lack role models for use of HPDs (e.g., in peers and advertising, contributing to their less frequent use of protection.

  12. Application of Detailed Phase Comparison Protection Models for the Analysis of its Operation in Networks with Facts Devices

    Directory of Open Access Journals (Sweden)

    Ruban Nikolay Yu.

    2015-01-01

    Full Text Available The problem of relay protection misoperations in networks with FACTS devices is considered in the paper. It is offered a solution to this problem for a phase comparison protection of transmission power line through the use of its detailed model for the analysis of the functioning for a case of various normal, emergency and post-emergency modes of electric power systems. The research results of this approach are given in the paper.

  13. Functional needs which led to the use of digital computing devices in the protection system of 1300 MW units

    International Nuclear Information System (INIS)

    Dalle, H.

    1986-01-01

    After a review of classical protection functions used in 900 MW power plants, it is concluded that in order to have functioning margins it is useful to calculate more finely the controled parameters. These calculating needs lead to the use of digital computing devices. Drawing profit from the new possibilities one can improve the general performances of the protection system with regard to availability, safety and maintenance. These options in the case of PALUEL led to the realization of SPIN, described here

  14. Distal finger replantation.

    Science.gov (United States)

    Scheker, Luis R; Becker, Giles W

    2011-03-01

    Reconstruction of the fingertip distal to the flexor tendon insertion by replantation remains controversial and technically challenging, but the anatomy of the fingertip has been well described and provides help in surgical planning. The open-book surgical technique is described with potential complications and is illustrated with clinical cases. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  15. Distal radioulnar joint injuries

    Directory of Open Access Journals (Sweden)

    Binu P Thomas

    2012-01-01

    Full Text Available Distal radioulnar joint is a trochoid joint relatively new in evolution. Along with proximal radioulnar joint , forearm bones and interosseous membrane, it allows pronosupination and load transmission across the wrist. Injuries around distal radioulnar joint are not uncommon, and are usually associated with distal radius fractures,fractures of the ulnar styloid and with the eponymous Galeazzi or Essex_Lopresti fractures. The injury can be purely involving the soft tissue especially the triangular fibrocartilage or the radioulnar ligaments.The patients usually present with ulnar sided wrist pain, features of instability, or restriction of rotation. Difficulty in carrying loads in the hand is a major constraint for these patients. Thorough clinical examination to localize point of tenderness and appropriate provocative tests help in diagnosis. Radiology and MRI are extremely useful, while arthroscopy is the gold standard for evaluation. The treatment protocols are continuously evolving and range from conservative, arthroscopic to open surgical methods. Isolated dislocation are uncommon. Basal fractures of the ulnar styloid tend to make the joint unstable and may require operative intervention. Chronic instability requires reconstruction of the stabilizing ligaments to avoid onset of arthritis. Prosthetic replacement in arthritis is gaining acceptance in the management of arthritis.

  16. Percutaneous renal angioplasty and stenting: application of embolic protection device in patients with normal renal function

    International Nuclear Information System (INIS)

    Tong Xiaoqiang; Yang Ming; Wang Jian; Song Li; Wang Chao; Lv Yongxing; Sun Hongliang; Zou Yinghua; Yin Ming

    2007-01-01

    Objective: To investigate the Value of embolic protection device (EPD)in renal artery stenting (RAS)for the patients with normal renal function. Methods: Total 24 patients (26 renal arteries) suffering from renal artery stenosis with normal serum creatinine were divided into two groups: EPD group (n12)and non-EPD group (n=12). Serum creatinine was calculated and analized statistically between the two groups, 1 month and 6months after stenting respectively, and followed by comparisons taking inside of each group and between both groups. Results: Serum creatinine of the EPD and non-EPD groups before, 1 month and 6 month after stenting were(99.18 ± 18.26) μmol/L, (101.73 ± 12.65) μmol/L, (96.82 ± 15.81) μmol/L and (100.18 ± 19.81) μmol/L, (107.36 ± 29.49) μmol/L, (127.64 ± 88.05) μmol/L, respectively; showing no significant difference inside each group individually (P>0.05), and also no statistically significant difference between the two groups (P>0.05). Conclusion: For the patients suffering from renal artery stenosis with normal serum creatinine, application of EPD may have no impact on renal function. Further evaluation is needed. (authors)

  17. About the influence of wheel slide protection devices action on longitudinal dynamic of trains

    Directory of Open Access Journals (Sweden)

    Cruceanu Cătălin

    2017-01-01

    Full Text Available Wheel slide protection devices (WSPD are destined to avoid important sliding of wheels during braking actions in case of temporarily impaired wheel-rail adhesion by correspondent reductions of air pressure in brake cylinders. Accordingly, longer braking distances and higher longitudinal in-train forces occur, potentially affecting the traffic safety and the passengers comfort. A general analyse and evaluation of these effects are the main targets of the present study. The theoretical considerations are sustained by simulations of braking process, considering situations of normal, respectively diminished wheel-rail adhesion determining random actuations of WSPD. The air pressure evolution in brake cylinders of was experimentally determined on a computerized brake system test stand and adequately used as input in simulations. The results indicate an increase of in-train forces and a more complex evolution of the longitudinal dynamic actions between the vehicles in the case of degraded wheel-rail adhesion, when the random actuation of WSPD have major influence in the whole braking process.

  18. Optical-electronic device based on diffraction optical element for control of special protective tags executed from luminophor

    Science.gov (United States)

    Polyakov, M.; Odinokov, S.

    2017-05-01

    The report focuses on special printing industry, which is called secure printing, which uses printing techniques to prevent forgery or falsification of security documents. The report considered the possibility of establishing a spectral device for determining the authenticity of certain documents that are protected by machine-readable luminophor labels. The device works in two spectral ranges - visible and near infrared that allows to register Stokes and anti-Stokes spectral components of protective tags. The proposed device allows verification of the authenticity of security documents based on multiple criteria in different spectral ranges. It may be used at enterprises related to the production of security printing products, expert units of law enforcement bodies at check of authenticity of banknotes and other structures.

  19. Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

    Energy Technology Data Exchange (ETDEWEB)

    D' Ercole, Loredana, E-mail: l.dercole@smatteo.pv.it [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Quaretti, Pietro; Cionfoli, Nicola [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy); Klersy, Catherine [Fondazione IRCCS Policlinico San Matteo, Biometry and Clinical Epidemiology Service, Research Department, (Italy); Bocchiola, Milena [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Rodolico, Giuseppe; Azzaretti, Andrea [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy); Lisciandro, Francesco [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Cascella, Tommaso; Zappoli Thyrion, Federico [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy)

    2013-04-15

    To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

  20. To a question on thermal protection of constructional elements of vacuum-plasma devices

    International Nuclear Information System (INIS)

    Borisko, V.N.; Borisko, S.V.; Zinovev, D.V.; Lapshin, V.I.; Tselujko, A.F.

    2005-01-01

    The progress in development of vacuum-plasma devices is connected with the design and creation of constructional elements from materials, which have a high erosion resistance and can maintain the large specific flux of energy per effective area. Recently as the materials of such constructional elements it was offered to use the reversible sorbents of hydrogen of Zr-V system, which have high-rates of sorption-desorption and large thermal effect of the hydride phases decomposition. In the paper an experimental research of the thermal conditions features of the metal-hydride electrodes, which subjected of the energy loads in the vacuum-plasma devices, are given. The simulation of the energy loads on the electrodes was carried out with the help of gas discharge plasma as there is an possibility to vary the energy spectrum of the bombarding particles and to gather a necessary radiation dose to the material surface. For comparative examinations of various materials under the irradiation by high-energy heavy particles it is the most convenient to use the Penning discharge. In this case, the cathodes made of different materials are under the identical conditions even at the change of working discharge modes. Therefore in the device on the basis of the Penning discharge the cathodes of metal-hydride and stainless steel were set. It was detected, that the increase of the temperature gradient of metal-hydride cathode goes down with the increase of discharge current value. The dependence of operating temperatures difference of cathodes from exposure time has shown that the temperature of the metal-hydride cathode is sufficiently lower than the temperature of the stainless steel cathode. Such a softening of the thermal operation conditions of the metal hydride cathode is caused by thermal decomposition of hydride phases. Besides there is the energy flow dissipation of bombarding particles on the protective gas target formed by desorbed hydrogen. The considerable decrease of

  1. Multicriteria Analysis model for the comparison of different rockfalls protection devices

    Science.gov (United States)

    Mignelli, C.; Pomarico, S.; Peila, D.

    2012-04-01

    which provides a comparison of the considered options. The developed model takes into account five different aspects of the decision-making process (economic, environmental, design, transport and social aspects) that have been organized according the hierarchical framework of the AHP technique. The criteria that were identified in the analysis and their weights, in the decision-making process, have been discussed and determined by means of specific focus groups with technical experts in the geo-engineering field. Three different protection devices, usually used for rockfall protection (embankment, shelter topped by rockfall barrier and tunnel), are compared through the AHP method, in a specific "geo" environment to show the feasibility of the method. The application of the AHP technique, which was performed using the Expert Choice software, allowed the most relevant aspects of the decision-making process to be highlighted and showing how the proposed method can be a valuable tool for public administration. Furthermore, in order to test the robustness of the proposed model a sensitivity analysis was carried out. The research has an originality value since it focuses on a participative methodological approach thus making the decision process more traceable and reliable.

  2. Measurement of hearing protection devices performance in the workplace during full-shift working operations.

    Science.gov (United States)

    Nélisse, Hugues; Gaudreau, Marc-André; Boutin, Jérôme; Voix, Jérémie; Laville, Frédéric

    2012-03-01

    The effectiveness of hearing protection devices (HPDs), when used in workplace conditions, has been shown over the years to be usually lower than the labeled values obtained under well-controlled laboratory conditions. Causes for such discrepancies have been listed and discussed by many authors. This study is an attempt to understand the issues in greater details and quantify some of these factors by looking at the performance of hearing protectors as a function of time during full work shift conditions. A non-invasive field microphone in the real ear (F-MIRE)-based method has been developed for measuring the effectiveness of different HPDs as a function of time in the workplace. Details of the test procedures, the equipment used, and the post-processing operations are presented and discussed. The methodology was developed in such a way that a complete time and frequency representation are possible. The system was used on a total of 24 workers in eight different companies. Work shifts of up to 9-h long were recorded. Various types of earmuffs and one type of molded earplugs were tested. Attenuation data reported as a function of time showed, for most workers tested, considerable fluctuations over entire work shift periods. Parts of these fluctuations are attributed to variations in the low-frequency content in the noise (in particular for earmuffs) as well as poor insertion and/or fitting of earplugs. Lower performances than laboratory-based ones were once again observed for most cases tested but also, important left and right ear differences were obtained for many individuals. When reported as a function of frequency, the attenuation results suggested that the few approximations used to relate the measurements to subjective real-ear-attenuation-at-threshold (REAT) data were realistic. The use of individualized attenuation data and performance ratings for HPDs as well as a good knowledge of the ambient noise in the workplace are key ingredients when evaluating the

  3. Social marketing campaign promoting the use of respiratory protection devices among farmers.

    Science.gov (United States)

    Pounds, Lea; Duysen, Ellen; Romberger, Debra; Cramer, Mary E; Wendl, Mary; Rautiainen, Risto

    2014-01-01

    This article describes the formal use of marketing concepts in a systematic approach to influence farmers to voluntarily increase respiratory protective device (RPD) use. The planning process for the project incorporated six key decision or action points, each informed by formative research or health behavior theory. The planning process included developing behavior change strategies based on a 4P model (product, price, place, and promotion). The resulting campaign elements included print and e-mail messages that leveraged motivators related to family and health in order to increase farmers' knowledge about the risks of exposure to dusty environments, four instructional videos related to the primary barriers identified in using RPDs, and a brightly colored storage bag to address barriers to using RPDs related to mask storage. Campaign implementation included a series of e-mails using a bulk e-mail subscription service, use of social media in the form of posting instructional videos on a YouTube channel, and in-person interactions with members of the target audience at farm shows throughout the Central States Center for Agricultural Safety and Health seven-state region. Evaluation of the e-mail campaigns indicated increased knowledge about RPD use and intent to use RPDs in dusty conditions. YouTube analytic data indicated continuing exposure of the instructional videos beyond the life of the campaign. The project demonstrates the efficacy of a planning process that incorporates formative research and clear decision points throughout. This process could be used to plan health behavior change interventions to address other agriculture-related health and safety issues.

  4. Soft tissue conduction as a possible contributor to the limited attenuation provided by hearing protection devices

    Directory of Open Access Journals (Sweden)

    Shai Chordekar

    2016-01-01

    Full Text Available Context: Damage to the auditory system by loud sounds can be avoided by hearing protection devices (HPDs such as earmuffs, earplugs, or both for maximum attenuation. However, the attenuation can be limited by air conduction (AC leakage around the earplugs and earmuffs by the occlusion effect (OE and by skull vibrations initiating bone conduction (BC. Aims: To assess maximum attenuation by HPDs and possible flanking pathways to the inner ear. Subjects and Methods: AC attenuation and resulting thresholds were assessed using the real ear attenuation at threshold (REAT procedure on 15 normal-hearing participants in four free-field conditions: (a unprotected ears, (b ears covered with earmuffs, (c ears blocked with deeply inserted customized earplugs, and (d ears blocked with both earplugs and earmuffs. BC thresholds were assessed with and without earplugs to assess the OE. Results: Addition of earmuffs to earplugs did not cause significantly greater attenuation than earplugs alone, confirming minimal AC leakage through the external meatus and the absence of the OE. Maximum REATs ranged between 40 and 46 dB, leading to thresholds of 46–54 dB HL. Furthermore, calculation of the acoustic impedance mismatch between air and bone predicted at least 60 dB attenuation of BC. Conclusion: Results do not support the notion that skull vibrations (BC contributed to the limited attenuation provided by traditional HPDs. An alternative explanation, supported by experimental evidence, suggests transmission of sound to inner ear via non-osseous pathways such as skin, soft tissues, and fluid. Because the acoustic impedance mismatch between air and soft tissues is smaller than that between air and bone, air-borne sounds would be transmitted to soft tissues more effectively than to bone, and therefore less attenuation is expected through soft tissue sound conduction. This can contribute to the limited attenuation provided by traditional HPDs. The present study

  5. Main radiation protection actions for medical personnel as primary responders front of an event with radiological dispersive device

    International Nuclear Information System (INIS)

    Duque, Hildanielle Ramos

    2015-01-01

    After the terrorist attack in New York, USA, in 2001, there was a worldwide concern about possible attacks using radioactive material in conventional detonators, called as Radiological Dispersal Device (RDD) or 'dirty bomb'. Several studies have been and are being made to form a global knowledge about this type of event. As until now, fortunately, there has not been an event with RDD, the Goiania Radiological Accident in Brazil, 1987, is used as a reference for decision-making. Several teams with technical experts should act in an event with RDD, but the medical staffs who respond quickly to the event must be properly protected from the harmful effects of radiation. Based on the radiological protection experts performance during the Goiania accident and the knowledge from lessons learned of many radiological accidents worldwide, this work presents an adaptation of the radiation protection actions for an event with RDD that helps a medical team as primary responders. The following aspects are presented: the problem of radioactive contamination from the explosion of the device in underground environment, the actions of the first responders and evaluation of health radiation effects. This work was based on specialized articles and papers about radiological accidents and RDD; as well as personal communication and academic information of the Institute of Radiation Protection and Dosimetry. The radiation protection actions, adapted to a terrorist attack event with RDD, have as a scenario a subway station in the capital. The main results are: the use of the basic radiation protection principle of time because there is no condition to take care of a patient keeping distance or using a shielding; the use of full appropriate protection cloths for contaminating materials ensuring the physical safety of professionals, and the medical team monitoring at the end of a medical procedure, checking for surface contamination. The main conclusion is that all medical actions

  6. Hybrid reed: Solid-state devices are a new generation of protective relays

    Directory of Open Access Journals (Sweden)

    Gurevich Vladimir

    2007-01-01

    Full Text Available Research and development in the field of electromechanical protective relays has not been conducted for tens of years. Author’s approach allows viewing the problem of re-equipment of relay protection in a new way. In the author’s opinion combination of reed switches with magnetic circuits and semiconductor elements opens new avenues in development of the promising protective relays featuring reliability, simplicity and low cost. Examples of protective relays made with these elements are given below.

  7. Biometric template data protection in mobile device environment using XML-database

    DEFF Research Database (Denmark)

    Thirumathyam, Rubathas; Derawi, Mohammad; Fischer, Paul

    2010-01-01

    recognition or gait recognition. To gain a real understanding of how it is possible to protect the biometric data, this paper first starts out with introducing a technique for security in a biometric system and emphasizes that template protection is important by going through the vulnerabilities and threats....... Furthermore, it points out requirements for template protection, a recital of various template protection schemes and a brief overview of biometric standards....

  8. 46 CFR 111.50-5 - Location of overcurrent protective devices.

    Science.gov (United States)

    2010-10-01

    ... Section 111.50-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-5 Location of overcurrent protective... primary side of a single phase transformer (two wire with single-voltage secondary) also protects the...

  9. A novel mechanical design of broken rope protection device for enhancing the safety performances of overhead manned equipment in coal mine

    Directory of Open Access Journals (Sweden)

    Xiaoguang Zhang

    2015-08-01

    Full Text Available A novel mechanical design of the broken rope protection device is proposed to enhance the safety performances of the overhead manned equipment. According to the operating characteristics and functional requirements of the overhead manned equipment, a three-dimensional mechanical model of the broken rope protection device was redesigned. Based on the known parameters of the mechanical model, the stress and strength of the main components are readjusted using the statics characteristics of finite element analysis. To ensure the reliability of the control system of the broken rope protection device, the process of people’s falling, the response performance of the tension sensor, and the signal extraction of the broken rope are analyzed under different loading and unloading speeds. The working principle of the broken rope protection device is expounded in detail. The experimental results showed that better effect is obtained by the new broken rope protection device, which is characterized by good durability, low investment, and high reliability.

  10. Thin-film encapsulation of organic electronic devices based on vacuum evaporated lithium fluoride as protective buffer layer

    Science.gov (United States)

    Peng, Yingquan; Ding, Sihan; Wen, Zhanwei; Xu, Sunan; Lv, Wenli; Xu, Ziqiang; Yang, Yuhuan; Wang, Ying; Wei, Yi; Tang, Ying

    2017-03-01

    Encapsulation is indispensable for organic thin-film electronic devices to ensure reliable operation and long-term stability. For thin-film encapsulating organic electronic devices, insulating polymers and inorganic metal oxides thin films are widely used. However, spin-coating of insulating polymers directly on organic electronic devices may destroy or introduce unwanted impurities in the underlying organic active layers. And also, sputtering of inorganic metal oxides may damage the underlying organic semiconductors. Here, we demonstrated that by utilizing vacuum evaporated lithium fluoride (LiF) as protective buffer layer, spin-coated insulating polymer polyvinyl alcohol (PVA), and sputtered inorganic material Er2O3, can be successfully applied for thin film encapsulation of copper phthalocyanine (CuPc)-based organic diodes. By encapsulating with LiF/PVA/LiF trilayer and LiF/Er2O3 bilayer films, the device lifetime improvements of 10 and 15 times can be achieved. These methods should be applicable for thin-film encapsulation of all kinds of organic electronic devices. Moisture-induced hole trapping, and Al top electrode oxidation are suggest to be the origins of current decay for the LiF/PVA/LiF trilayer and LiF/Er2O3 bilayer films encapsulated devices, respectively.

  11. Protecting computer-based medical devices: defending against viruses and other threats.

    Science.gov (United States)

    2005-07-01

    The increasing integration of computer hardware has exposed medical devices to greater risks than ever before. More and more devices rely on commercial off-the-shelf software and operating systems, which are vulnerable to the increasing proliferation of viruses and other malicious programs that target computers. Therefore, it is necessary for hospitals to take steps such as those outlined in this article to ensure that their computer-based devices are made safe and continue to remain safe in the future. Maintaining the security of medical devices requires planning, careful execution, and a commitment of resources. A team should be created to develop a process for surveying the security status of all computerized devices in the hospital and making sure that patches and other updates are applied as needed. These patches and updates should be approved by the medical system supplier before being implemented. The team should consider using virtual local area networks to isolate susceptible devices on the hospital's network. All security measures should be carefully documented, and the documentation should be kept up-to-date. Above all, care must be taken to ensure that medical device security involves a collaborative, supportive partnership between the hospital's information technology staff and biomedical engineering personnel.

  12. Efficient Protection of Android Applications through User Authentication Using Peripheral Devices

    OpenAIRE

    Jinseong Kim; Im Y. Jung

    2018-01-01

    Android applications store large amounts of sensitive information that may be exposed and exploited. To prevent this security risk, some applications such as Syrup and KakaoTalk use physical device values to authenticate or encrypt application data. However, by manipulating these physical device values, an attacker can circumvent the authentication by executing a Same Identifier Attack and obtain the same application privileges as the user. In our work, WhatsApp, KakaoTalk, Facebook, Amazon, ...

  13. 30 CFR 77.802 - Protection of high-voltage circuits; neutral grounding resistors; disconnecting devices.

    Science.gov (United States)

    2010-07-01

    ... AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.802 Protection... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection of high-voltage circuits; neutral... grounded through a suitable resistor at the source transformers, and a grounding circuit, originating at...

  14. Reliability of microprocessor-based relay protection devices: Myths and reality

    Directory of Open Access Journals (Sweden)

    Gurevich Vladimir

    2009-01-01

    Full Text Available The article examines four basic theses about the ostensibly extremely high reliability of microprocessor-based relay protection (MP touted by supporters of MP. Through detailed analysis based on many references it is shown that the basis of these theses are widespread myths, and actually MP reliability is lower than the reliability of electromechanical and electronic protective relays on discrete components.

  15. Electric protection of the ion sources of the Ogra-4 device

    International Nuclear Information System (INIS)

    Matveev, N.V.; Obysov, V.A.

    1984-01-01

    Electric circuit of an ion source power supply comprising elements for protection from damages in case of discharges inside the source, has been described. The possibility of protection against discharge and subsequent reclosing switching of the ion source using consecutive protective key element in the circuit of power supply emission electrode, electron commutator being used as one, has been studied. Results of the use of commutators on the basis of electron-beam valves as the main commutating element are presented. Application of the circuit described permitted to achieve voltage restoration on the ion source electrodes when the valve reclosing switching time delay constituted 200 μs

  16. Distal corporoplasty for distal cylinders extrusion after penile prosthesis implantation.

    Science.gov (United States)

    Carrino, Maurizio; Chiancone, Francesco; Battaglia, Gaetano; Pucci, Luigi; Fedelini, Paolo

    2017-02-03

    Distal extrusion of cylinders is a potential complication of the penile prosthesis implantation. Several methods have been proposed for repairing a distal penile erosion. We present our preliminary experience in "Distal corporoplasty" technique. We enrolled 18 consecutive patients whose underwent a distal corporoplasty with simultaneous reimplantation of an "AMS 700 inflatable penile prosthesis (LGX)" from January 2013 to November 2015 at our hospital. All procedures were performed by a single surgical team. Intraoperative and postoperative complications have been classified and reported according to Satava6 and Clavien-Dindo (CD) system.7 Mean values with standard deviations (±SD) were computed and reported for all items. Mean age of the patients was 53.61 (±11.90) years. Mean body max index (BMI) was 24.22 (±2.51). Mean operative time was 85.2 (±13.1) minutes. Blood losses were minimal. No intraoperative complications are reported according to Satava classification. Four out of 18 patients (22.22%) experienced postoperative complications according to CD system. All patients had sexual intercourse for the first time postsurgery after a mean of 59.11 ± 2.08 days. Mean follow-up was 22.11 (±9.95). Distal extrusion of cylinders is a potential complication of the penile prosthesis implantation. Distal corporoplasty was first described by Mulcahy. He reported a series of 14 patients with a follow-up of about 2 years with optimal functional outcomes. Moreover, distal corporoplasty resulted in shorter operative time, better function, less pain, and fewer recurrences than Gortex windsock repair.10 In our experience, distal corporoplasty is a simple and safe procedure in the treatment of distal cylinders extrusion when the prosthetic material is not exposed to the exterior.

  17. Location Privacy Protection Based on Improved K-Value Method in Augmented Reality on Mobile Devices

    Directory of Open Access Journals (Sweden)

    Chunyong Yin

    2017-01-01

    Full Text Available With the development of Augmented Reality technology, the application of location based service (LBS is more and more popular, which provides enormous convenience to people’s life. User location information could be obtained at anytime and anywhere. So user location privacy security suffers huge threats. Therefore, it is crucial to pay attention to location privacy protection in LBS. Based on the architecture of the trusted third party (TTP, we analyzed the advantages and shortages of existing location privacy protection methods in LBS on mobile terminal. Then we proposed the improved K-value location privacy protection method according to privacy level, which combines k-anonymity method with pseudonym method. Through the simulation experiment, the results show that this improved method can anonymize all service requests effectively. In addition to the experiment of execution time, it demonstrated that our proposed method can realize the location privacy protection more efficiently.

  18. Ubiquitous Nature of Distal Athero/Thromboembolic Events during Lower Extremity Atherectomy Procedures Involving the Superficial Femoral Artery

    Science.gov (United States)

    Wasty, Najam; Khakwani, M. Z.; Kotev, Spas; Boiangiu, Catalin; Hasan, Omar; Anna, Manjusha; Tayal, Rajiv; Kaid, Khalil; Baker, Gail; Cohen, Marc

    2016-01-01

    This study aims to evaluate occurrence, size, composition, and clinical significance of embolized debris during superficial femoral artery atherectomy using all commercially available atherectomy devices. Distal athero/thromboembolic events (DATE) are a universal phenomenon in lower extremity atherectomy procedures (LEAPs) due to the sheer volume of atheroma and the thrombus burden in peripheral arterial disease. Some of these events can be clinically significant. We prospectively gathered clinical and histopathological data on all commercially available atherectomy devices by using embolic protection devices (EPD) in every case. After intervention, the contents of EPD were examined both microscopically and macroscopically. Data from 59 consecutive patients undergoing LEAP were analyzed. DATE occurred 100% of the time. The composition of particulate debris varied with the device used. Grossly visible agglomerated debris was captured by the filter in the majority of patients 54/59 (91.5%). Clinically significant debris, defined by the Preventing Lower Extremity Distal Embolization Using Embolic Filter Protection registry as particle diameter > 0.2 cm, was found in 33/59 (56%) patients. The size of captured debris particles ranged from 0.1 to 2.4 mm. While DATE occurred in all patients, clinically significant DATE occurred in 56% patients undergoing LEAP regardless of the atherectomy device. In spite of a large fraction of the clinically significant debris occurring on our routine dual antiplatelet regimen, no patient suffered an amputation. Although DATE was prevented by the use of EPD in all 59 cases, more data are needed to determine whether the use of EPD translates into a long-term clinical benefit. Use of EPD and optimal thromboprophylaxis should be considered in patients, especially in the setting of compromised distal runoff. PMID:27867291

  19. Evaluation of personal protective devices used in diagnostic radiology; Avaliacao de dispositivos de protecao individual utilizados em radiologia diagnostica

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Fernanda Cristina Salvador

    2006-07-01

    In this work protective devices of five manufacturers were evaluated according to the NBR/IEC 61331-1 and NBR/IEC 61331-3 standards. Three different methodologies (linear interpolation, Archer model and sum of exponentials) were applied for the determination of the attenuation equivalent, since the standard does not indicate how it must be determined. Moreover, the uncertainties associated to each method, and the influence of the number of measurements in the combined uncertainty were estimated. The evaluated manufacture characteristics were: accompanying document, design, materials, dimensions and label marking. For this evaluation a check list about the requirements of the NBR/IEC 61331-3 standard was elaborated. The results showed a great difference between nominal and measured attenuation equivalent values. The comparison of the results using the three methodologies showed small variations among the obtained values and among the associated uncertainties in the different methodologies. It was possible to observe that the number of measurements does not contribute significantly for the increase of the uncertainty in all three methodologies. The best methodology for the laboratory routine is the linear interpolation methodology, with five measurements for each air kerma rate value. The discrepancy between the results obtained in this work and the requirements of the applied standards show the need to adopt a compulsory certification process for protective devices, thus contributing for the increase of the radiation protection of the users. (author)

  20. AntibIoTic: Protecting IoT Devices Against DDoS Attacks

    DEFF Research Database (Denmark)

    De Donno, Michele; Dragoni, Nicola; Giaretta, Alberto

    2018-01-01

    The 2016 is remembered as the year that showed to the world how dangerous Distributed Denial of Service attacks can be. Gauge of the disruptiveness of DDoS attacks is the number of bots involved: the bigger the botnet, the more powerful the attack. This character, along with the increasing...... availability of connected and insecure IoT devices, makes DDoS and IoT the perfect pair for the malware industry. In this paper we present the main idea behind AntibIoTic, a palliative solution to prevent DDoS attacks perpetrated through IoT devices....

  1. Mini-implant-supported Molar Distalization

    Directory of Open Access Journals (Sweden)

    Amit Goyal

    2012-01-01

    Full Text Available Temporary anchorage devices popularly called mini-implants or miniscrews are the latest addition to an orthodontist′s armamentarium. The following case report describes the treatment of a 16-year-old girl with a pleasant profile, moderate crowding and Angle′s Class II molar relationship. Maxillary molar distalization was planned and mini-implants were used to preserve the anterior anchorage. After 13 months of treatment, Class I molar and canine relation was achieved bilaterally and there was no anterior proclination. Thus, mini-implants provide a viable option to the clinician to carry out difficult tooth movements without any side effects.

  2. Enabling GPU-assisted Antivirus Protection on Android Devices Through Edge Offloading

    DEFF Research Database (Denmark)

    Deyannis, Dimitris; Tsirbas, Rafail; Vasiliadis, Giorgos

    2018-01-01

    Antivirus software are the most popular tools for detecting and stopping malicious or unwanted files. However, the performance requirements of traditional host-based antivirus make their wide adoption to mobile, embedded, and hand-held devices questionable. Their computational- and memory...

  3. Thermal protection of electronic devices with the Nylon6/66-PEG nanofiber membranes

    OpenAIRE

    Li Ya; Li Xue-Weis; He Ji-Huan; Wang Ping

    2014-01-01

    Phase change materials for thermal energy storage have been widely applied to clothing insulation, electronic products of heat energy storage. The thermal storage potential of the nanofiber membranes was analyzed using the differential scanning calorimetry. Effect of microstructure of the membrane on energy storage was analyzed, and its applications to electronic devices were elucidated.

  4. Protection of stapled colorectal anastomoses with a biodegradable device : the C-Seal feasibility study

    NARCIS (Netherlands)

    Kolkert, Joe L.; Havenga, Klaas; Hoedemaker, Henk O. ten Cate; Zuidema, Johan; Ploeg, Rutger J.

    BACKGROUND: A colorectal anastomotic leak can be life-threatening. We have assessed the feasibility of a new intraluminal biodegradable bypass device that we designed to avoid anastomotic leakage and the necessity of a temporary stoma. METHODS: Fifteen patients underwent colorectal surgery. Before

  5. Multiobjective optimal placement of switches and protective devices in electric power distribution systems using ant colony optimization

    Energy Technology Data Exchange (ETDEWEB)

    Tippachon, Wiwat; Rerkpreedapong, Dulpichet [Department of Electrical Engineering, Kasetsart University, 50 Phaholyothin Rd., Ladyao, Jatujak, Bangkok 10900 (Thailand)

    2009-07-15

    This paper presents a multiobjective optimization methodology to optimally place switches and protective devices in electric power distribution networks. Identifying the type and location of them is a combinatorial optimization problem described by a nonlinear and nondifferential function. The multiobjective ant colony optimization (MACO) has been applied to this problem to minimize the total cost while simultaneously minimize two distribution network reliability indices including system average interruption frequency index (SAIFI) and system interruption duration index (SAIDI). Actual distribution feeders are used in the tests, and test results have shown that the algorithm can determine the set of optimal nondominated solutions. It allows the utility to obtain the optimal type and location of devices to achieve the best system reliability with the lowest cost. (author)

  6. Overcurrent protection co-ordination: A modern approach for modern devices

    Energy Technology Data Exchange (ETDEWEB)

    Hindle, P.J.

    1995-12-31

    The increasing densities and reduced geographical spans of urban and industrial power systems call for the coordination of more stages of overcurrent protection up to increasingly high fault levels. Applying existing rules of relay coordination, especially for industrial power systems, may make achieving satisfactory coordination difficult. This paper proposes a modern approach to coordination which is able to take advantage of the improved performance of modern protective relays and circuit breakers. The proposed method can handle a mix of new and old equipment and is made most useful when implemented with commonly available spreadsheet software. The suggested approach justifies reduced time margins for relay coordination in many difficult applications. Example calculations are included to illustrate typical considerations for coordinating two digital protection relays where a vacuum circuit breaker is used to clear a downstream fault.

  7. An investigation into the effect of protective devices on the dose to radiosensitive organs in the head and neck

    International Nuclear Information System (INIS)

    Marshall, N.W.; Faulkner, K.; Clarke, P.

    1992-01-01

    A series of experiments were performed to determine the dose reduction afforded to radiosensitive organs in the head and neck by various protective devices. These included spectacles with plastic, standard glass, photochromic and lead-glass lenses, a thyroid collar and a lead-acrylic face mask. The measurements were performed using an anthropomorphic phantom loaded with lithium fluoride thermoluminescent dosemeters, in conditions realistic of clinical practice. Irradiations were performed using scattered radiation produced by a pelvic phantom, for X-ray beams generated at 80 kVp and 110 KVp. Also presented is the ratio of organ dose to dose to the bridge of the nose for thyroid, oesophagus, brain and sinuses, as measured for the case of no head or neck protection. (author)

  8. Definition and production of calibration standard neutron sources for radiation protection device calibration

    International Nuclear Information System (INIS)

    De Matos, E.

    1987-01-01

    To improve the characterization of radioprotection devices performances, it would be advisable to calibrate these devices in neutron spectra which are nearly like those met in practice (nuclear reactors, plutonium technology laboratories...). The purpose of this work is, in a first time, to choose the nature and the dimensions of the different shields used to achieve broad typical neutron spectra extending to lower energies from a 14.8 MeV neutron beam. The second step is the evaluation of spectral distribution and calculation of associated dosimetric quantities. For that, several spectrometric techniques are employed: on one hand, activation detectors and Bonner spheres method named rough spectrometry; on the other hand, an accurate spectrometry which uses recoil proton counters. The dosimetric quantities, especially the value of kerma deduced from these spectra must be in good agreement with those measured with a tissue equivalent ionization chamber [fr

  9. Ionizing secondary radiation generated by analog radiological and digital coronary cine angiographic equipment. Influence of external protection devices

    International Nuclear Information System (INIS)

    Ramirez N, Alfredo; Farias Ch, Eric; Silva J, Ana Maria; Leyton L, Fernando; Oyarzun C, Carlos; Ugalde P, Hector; Dussaillant, Gaston; Cumsille G, Angel

    2000-01-01

    Exposure to ionizing radiation is a know hazard of radiological procedures. Aim: to compare the emission of secondary ionizing radiation from two coronary angiographic equipments, one with digital and the other with analog image generation. To evaluate the effectiveness of external radiological protection devices. Material and methods: environmental and fluoroscopy generated radiation in the cephalic region of the patient was measured during diagnostic coronary angiographies. Ionizing radiation generated in anterior left oblique protection (ALO) and anterior right oblique protection (ARO) were measured with and without leaded protections. In 19 patients (group 1), a digital equipment was used and in 21 (group 2), an analog equipment. Results: header radiation for group 1 and 2 was 1194±337 and 364±222 μGray/h respectively (p≤0.001). During fluoroscopy and with leaded protection generated radiation for groups 1 and 2 was 612±947 and 70±61μGray/h respectively (p≤0.001). For ALO projection, generated for groups 1 and 2 was 105±47 and 71±192 μGray/h respectively (p≤0.001). During filming the radiation for ALO projection for groups 1 and 2 was 7252±9569 and 1671±2038 μGray/h respectively (p=0.03). Out of the protection zone, registered radiation during fluoroscopy for groups 1 and 2 was 2800±1741 and 1318±954 μGray/h respectively (p≤0.001); during filming, the figures were 15500±5840 and 18961±10599 μGray/h respectively (NS). Conclusions: digital radiological equipment has a lower level of ionizing radiation emission than the analog equipment

  10. Perspective pulse devices and automatic systems fire explosive protection of the radioactive infected objects

    International Nuclear Information System (INIS)

    Zakhmatov, V.D.; Kozhemyakin, A.S.; Pyatova, A.V.

    1999-01-01

    The suppression of fires in Chernobyl zone has shown complete unprofitable of traditional fire engineering to work on is radioactive of the infected district. In this connection as effective ways extinguishive in object 'Shelter' alongside with known traditional means and the systems offer to apply more perspective pulse systems, based on use energy small practically safe charges of gunpowder or explosive substances, in particular. Pulse explosive cone extinguishive of the device various sizes

  11. Process and device for the protection of steam-raising units, particularly of nuclear reactors

    International Nuclear Information System (INIS)

    Beyer, W.; Wieling, N.; Stellwag, B.

    1986-01-01

    To protect the housing against corrosion by chemical conditioning of the feedwater, the redox potential of the feedwater and the corrosion potential of at least one pipe of the pipe bundle is continuously determined during operation of the steam raising unit. With potentials indicating the danger of corrosion, the quality of the secondary water can be improved by suitable measures. (orig./HP) [de

  12. Improvements in or relating to the protection of thermoelectric devices against shocks and accelerations

    International Nuclear Information System (INIS)

    Brown, M.H.; Myatt, J.

    1979-01-01

    Heart pacemakers are protected against shock and acceleration by surrounding the heat source, but not in contact with the source or the thermoelectric unit, with a plurity of spring fingers. These arrest the radioactive source in the event of movement on its resilient mounting of the thermoelectric unit relative to the casing in excess of a predetermined amount. (UK)

  13. Efficient Protection of Android Applications through User Authentication Using Peripheral Devices

    Directory of Open Access Journals (Sweden)

    Jinseong Kim

    2018-04-01

    Full Text Available Android applications store large amounts of sensitive information that may be exposed and exploited. To prevent this security risk, some applications such as Syrup and KakaoTalk use physical device values to authenticate or encrypt application data. However, by manipulating these physical device values, an attacker can circumvent the authentication by executing a Same Identifier Attack and obtain the same application privileges as the user. In our work, WhatsApp, KakaoTalk, Facebook, Amazon, and Syrup were subjected to the Same Identifier Attack, and it was found that an attacker could gain the same privileges as the user, in all five applications. To solve such a problem, we propose a technical scheme—User Authentication using Peripheral Devices. We applied the proposed scheme to a Nexus 5X smartphone running Android version 7.1 and confirmed that the average execution time was 0.005 s, which does not affect the other applications’ execution significantly. We also describe the security aspects of the proposed scheme and its compatibility with the Android platform and other applications. The proposed scheme is practical and efficient in terms of resource usage; therefore, it will be useful for Android users to improve Android application security.

  14. Comparison of performance of three different types of respiratory protection devices.

    Science.gov (United States)

    Lawrence, Robert B; Duling, Matthew G; Calvert, Catherine A; Coffey, Christopher C

    2006-09-01

    Respiratory protection is offered to American workers in a variety of ways to guard against potential inhalation hazards. Two of the most common ways are elastomeric N95 respirators and N95 filtering-facepiece respirators. Some in the health care industry feel that surgical masks provide an acceptable level of protection in certain situations against particular hazards. This study compared the performance of these types of respiratory protection during a simulated workplace test that measured both filter penetration and face-seal leakage. A panel of 25 test subjects with varying face sizes tested 15 models of elastomeric N95 respirators, 15 models of N95 filtering-facepiece respirators, and 6 models of surgical masks. Simulated workplace testing was conducted using a TSI PORTACOUNT Plus model 8020, and consisted of a series of seven exercises. Six simulated workplace tests were performed with redonning of the respirator/mask occurring between each test. The results of these tests produced a simulated workplace protection factor (SWPF). The geometric mean (GM) and the 5th percentile values of the SWPFs were computed by category of respiratory protection using the six overall SWPF values. The level of protection provided by each of the three respiratory protection types was compared. The GM and 5th percentile SWPF values without fit testing were used for the comparison, as surgical masks were not intended to be fit tested. The GM values were 36 for elastomeric N95 respirators, 21 for N95 filtering-facepiece respirators, and 3 for surgical masks. An analysis of variance demonstrated a statistically significant difference between all three. Elastomeric N95 respirators had the highest 5th percentile SWPF of 7. N95 filtering-facepiece respirators and surgical masks had 5th percentile SWPFs of 3 and 1, respectively. A Fisher Exact Test revealed that the 5th percentile SWPFs for all three types of respiratory protection were statistically different. In addition, both

  15. Balancing protection of public health and safety with the free movement of goods in the EU medical device sector : The case of ‘borderline products’ classification

    NARCIS (Netherlands)

    Tseliou, Tasoula

    2015-01-01

    In 2013, the CJEU ruled on the ‘Lyocentre’ case touching upon an important and contemporary issue in the EU Medical Device regime – the classification issue between medical devices and medicinal products. This problem is connected with the internal market v. protection of health dilemma as well as

  16. Reference neutron radiations. Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field

    International Nuclear Information System (INIS)

    2000-01-01

    ISO 8529 consists of the following parts, under the general title Reference neutron radiations: Part 1: Characteristics and methods of production; Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field; Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence. This Part 2. of ISO 8529 takes as its starting point the neutron sources described in ISO 8529-1. It specifies the procedures to be used for realizing the calibration conditions of radiation protection devices in neutron fields produced by these calibration sources, with particular emphasis on the corrections for extraneous effects (e.g., the neutrons scattered from the walls of the calibration room). In this part of ISO 8529, particular emphasis is placed on calibrations using radionuclide sources (clauses 4 to 6) due to their widespread application, with less details given on the use of accelerator and reactor sources (8.2 and 8.3). This part of ISO 8529 then leads to ISO 8529-3 which gives conversion coefficients and the general rules and procedures for calibration

  17. Operating devices for radiation protection: acceptable deviations from legal metrology point of view

    International Nuclear Information System (INIS)

    Soukup, T.

    2008-01-01

    The objective of this paper is to draw attention to possible discrepancies in the measuring the quantities of ionizing radiation mainly in natural environment, that cannot be explained by faulty gauges. In addition I would like to draw the attention to these issue radiation protection researchers, document that uncertainties in estimating the impact of exposure and transfer them into the language of used meters tolerances. (authors)

  18. Class II correction prior to orthodontics with the carriere distalizer.

    Science.gov (United States)

    McFarlane, Bruce

    2013-01-01

    Class II correction is a challenge in orthodontics with many existing devices being complex, too compliance-driven, or too prone to breakage. The Carriere Distalizer allows for straightforward Class II correction prior to orthodontics (fixed or clear aligners) at a time when no other mechanics interfere, and compliance is at its best.

  19. Evaluation of novel disposable, light-weight radiation protection devices in an interventional radiology setting: a randomized controlled trial.

    Science.gov (United States)

    Uthoff, Heiko; Peña, Constantino; West, James; Contreras, Francisco; Benenati, James F; Katzen, Barry T

    2013-04-01

    Radiation exposure to interventionalists is increasing. The currently available standard radiation protection devices are heavy and do not protect the head of the operator. The aim of this study was to evaluate the effectiveness and comfort of caps and thyroid collars made of a disposable, light-weight, lead-free material (XPF) for occupational radiation protection in a clinical setting. Up to two interventional operators were randomized to wear a XPF or standard 0.5-mm lead-equivalent thyroid collars in 60 consecutive endovascular procedures requiring fluoroscopy. Simultaneously a XPF cap was worn by all operators. Radiation doses were measured using dosimeters placed outside and underneath the caps and thyroid collars. Wearing comfort was assessed at the end of each procedure on a visual analog scale (0-100 [100 = optimal]). Patient and procedure data did not differ between the XPF and standard protection groups. The cumulative radiation dose measured outside the cap was 15,700 μSv and outside the thyroid collars 21,240 μSv. Measured radiation attenuation provided by the XPF caps (n = 70), XPF thyroid collars (n = 40), and standard thyroid collars (n = 38) was 85.4% ± 25.6%, 79.7% ± 25.8% and 71.9% ± 34.2%, respectively (mean difference XPF vs standard thyroid collars, 7.8% [95% CI, -5.9% to 21.6%]; p = 0.258). The median XPF cap weight was 144 g (interquartile range, 128-170 g), and the XPF thyroid collars were 27% lighter than the standard thyroid collars (p disposable caps and thyroid collars made of XPF were assessed as being comfortable to wear, and they provide radiation protection similar to that of standard 0.5-mm lead-equivalent thyroid collars.

  20. Preparation and thermal performance of paraffin/Nano-SiO2 nanocomposite for passive thermal protection of electronic devices

    International Nuclear Information System (INIS)

    Wang, Yaqin; Gao, Xuenong; Chen, Peng; Huang, Zhaowen; Xu, Tao; Fang, Yutang; Zhang, Zhengguo

    2016-01-01

    Highlights: • Three types of paraffin/nano-SiO 2 nanocomposites were prepared and characterized. • Thermo-physical properties of these composites were determined and compared. • One composite with lower thermal conductivity showed better thermal insulation properties. • This composite was identified as thermal insulation material for electronic components. - Abstract: In this paper, three grades of nano silicon dioxide (nano-SiO 2 ), NS1, NS2 and NS3, were mixed into paraffin to prepare nanocomposites as novel insulation materials for electronic passive thermal protection applications. The optimal mass percentages of paraffin for the three composites, NS1P, NS2P and NS3P, were determined to be 75%, 70% and 65%, respectively. Investigations by means of scanning electron micrographs (SEM), differential scanning calorimeter (DSC), thermogravimetric analysis (TG), hot disk analyzer and thermal protection performance tests were devoted to the morphology, thermal properties and thermal protection performance analysis of composites. Experimental results showed that paraffin uniformly distributed into the pores and on the surface of nano-SiO 2 . Melting points of composites declined and experimental latent heat became lower than the calculated values with the decrease of nano-SiO 2 pore size. The NS1P composite had larger thermal storage capacity, better reliability and stability compared with NS2P and NS3P. In addition, compared with 90% wt.% paraffin/EG composite, the incorporation of NS1 (25 wt.%) into paraffin caused not only 63.2% reduction in thermal conductivity, but also 21.8% increase in thermal protection time affected by the ambient temperature. Thus those good properties confirmed that NS1P (75 wt.%) composite was a viable candidate for protecting electronic devices under high temperature environment.

  1. Exploiting heat treatment effects on SMAs macro and microscopic properties in developing fire protection devices

    Science.gov (United States)

    Burlacu, L.; Cimpoeşu, N.; Bujoreanu, L. G.; Lohan, N. M.

    2017-08-01

    Ni-Ti shape memory alloys (SMAs) are intelligent alloys which demonstrate unique properties, such as shape memory effect, two-way shape memory effect, super-elasticity and vibration damping which, accompanied by good processability, excellent corrosion resistance and biocompatibility as well as fair wear resistance and cyclic stability, enabled the development of important industrial applications (such as sensors, actuators, fasteners, couplings and valves), medical applications (such as stents, bone implants, orthodontic archwires, minimal invasive surgical equipment) as well as environmental health and safety devices (anti-seismic dampers, fire safety devices). The phase transitions in Ni-Ti SMAs are strongly influenced by processing methods, chemical compositions and thermomechanical history. This paper presents a study of the effects of heat treatment on the mechanical and thermal properties of commercial Ni-Ti shape memory alloy (SMA). The experimental work involved subjecting a SMA rod to heat-treatment consisting in heating up to 500°C, 10 minutes-maintaining and water quenching. Mechanical properties were highlighted by microhardness tests while thermal characteristics were emphasized by differential scanning calorimetry (DSC). The presence of chemical composition fluctuations was checked by X-ray energy dispersive spectroscopy performed with an EDAX Bruker analyzer.

  2. Overcurrent protection co-ordination. A modern approach for modern devices

    Energy Technology Data Exchange (ETDEWEB)

    Hindle, P. [GEC Alsthom Engineering Systems Ltd., Whetstone (United Kingdom); Sanderson, J.V.H. [Power Engineering Consultants Ltd., Cheshire (United Kingdom)

    1995-12-31

    A modern approach to relay co-ordination that takes advantage of the improved performance of modern protective relays and circuits was proposed. The proposed method dealt with a mixture of new and old equipment and was most useful when implemented using common spreadsheet software. The suggested approach justified reduced time margins for relay co-ordination in many difficult applications. Other established approaches were reviewed. A discussion of fixed and variable time margin allowances was presented. The formulation of an equation to determine the required upstream relay operating time was explained, with sample calculations. Relay performance standards and modern protective equipment were discussed. It was concluded that modern relays and circuit breakers are much more advanced than designs of the recent past. The method described allowed significant reductions in margins which enabled modern relays to operate faster. While calculations for the procedures were said to be tedious to perform by hand, they can be easily done with spreadsheet software. 10 refs., 4 figs.

  3. Analysis of the network protection devices action connected with the Krsko NPP operation safety

    International Nuclear Information System (INIS)

    Omahen, P.; Struc, S.

    1995-01-01

    The example of failure that took place in Zagreb on 30 March, 1995, has been investigated in order to obtain appropriate answers to the unexpected electric power system (ESP) response and consecutive outage of the Krsko nuclear power plant (NPP). The analysis has been made of particular operating and stability conditions, related to the functioning of distance relays line protection. Using a consequent simulation model of the EPS (European interconnection) under specified fault condition, the research of EPS operation (relays action) and stability has been done. The appropriate simulation results have been compared to the available measured data which had been collected by the SOREL on-line data acquisition system. In the end, a practise proposal for measures to be taken with the target of achieving the foreseen and expected operation of the EPS equipment that effects operation of the Krsko NPP is given. (author)

  4. Isopropyl Myristate-Modified Polyether-Urethane Coatings as Protective Barriers for Implantable Medical Devices

    Science.gov (United States)

    Roohpour, Nima; Wasikiewicz, Jaroslaw M.; Moshaverinia, Alireza; Paul, Deepen; Rehman, Ihtesham U.; Vadgama, Pankaj

    2009-01-01

    Polyurethane films have potential applications in medicine, especially for packaging implantable medical devices. Although polyether-urethanes have superior mechanical properties and are biocompatible, achieving water resistance is still a challenge. Polyether based polyurethanes with two different molecular weights (PTMO1000, PTMO2000) were prepared from 4,4’-diphenylmethane diisocyanate and poly(tetra-methylene oxide). Polymer films were introduced using different concentrations (0.5-10 wt %) of isopropyl myristate lipid (IPM) as a non-toxic modifying agent. The physical and mechanical properties of these polymers were characterised using physical and spectroscopy techniques (FTIR, Raman, DSC, DMA, tensile testing). Water contact angle and water uptake of the membranes as a function of IPM concentration was also determined accordingly. The FTIR and Raman data indicate that IPM is dispersed in polyurethane at ≤ 2wt% and thermal analysis confirmed this miscibility to be dependent on soft segment length. Modified polymers showed increased tensile strength and failure strain as well as reduced water uptake by up to 24% at 1-2 wt% IPM.

  5. Isopropyl Myristate-Modified Polyether-Urethane Coatings as Protective Barriers for Implantable Medical Devices

    Directory of Open Access Journals (Sweden)

    Pankaj Vadgama

    2009-06-01

    Full Text Available Polyurethane films have potential applications in medicine, especially for packaging implantable medical devices. Although polyether-urethanes have superior mechanical properties and are biocompatible, achieving water resistance is still a challenge. Polyether based polyurethanes with two different molecular weights (PTMO1000, PTMO2000 were prepared from 4,4’-diphenylmethane diisocyanate and poly(tetra-methylene oxide. Polymer films were introduced using different concentrations (0.5-10 wt % of isopropyl myristate lipid (IPM as a non-toxic modifying agent. The physical and mechanical properties of these polymers were characterised using physical and spectroscopy techniques (FTIR, Raman, DSC, DMA, tensile testing. Water contact angle and water uptake of the membranes as a function of IPM concentration was also determined accordingly. The FTIR and Raman data indicate that IPM is dispersed in polyurethane at ≤ 2wt% and thermal analysis confirmed this miscibility to be dependent on soft segment length. Modified polymers showed increased tensile strength and failure strain as well as reduced water uptake by up to 24% at 1-2 wt% IPM.

  6. Traumatic Distal Ulnar Artery Thrombosis

    Directory of Open Access Journals (Sweden)

    Ahmet A. Karaarslan

    2014-01-01

    Full Text Available This paper is about a posttraumatic distal ulnar artery thrombosis case that has occurred after a single blunt trauma. The ulnar artery thrombosis because of chronic trauma is a frequent condition (hypothenar hammer syndrome but an ulnar artery thrombosis because of a single direct blunt trauma is rare. Our patient who has been affected by a single blunt trauma to his hand and developed ulnar artery thrombosis has been treated by resection of the thrombosed ulnar artery segment. This report shows that a single blunt trauma can cause distal ulnar artery thrombosis in the hand and it can be treated merely by thrombosed segment resection in suitable cases.

  7. Evaluation of the Survivability of Microorganisms Deposited on Filtering Respiratory Protective Devices under Varying Conditions of Humidity

    Directory of Open Access Journals (Sweden)

    Katarzyna Majchrzycka

    2016-01-01

    Full Text Available Bioaerosols are common biological factors in work environments, which require routine use of filtering respiratory protective devices (FRPDs. Currently, no studies link humidity changes in the filter materials of such devices, during use, with microorganism survivability. Our aim was to determine the microclimate inside FRPDs, by simulating breathing, and to evaluate microorganism survivability under varying humidity conditions. Breathing was simulated using commercial filtering facepiece respirators in a model system. Polypropylene melt-blown nonwoven fabrics with moisture contents of 40%, 80%, and 200%, were used for assessment of microorganisms survivability. A modified AATCC 100-2004 method was used to measure the survivability of ATCC and NCAIM microorganisms: Escherichia coli, Staphylococcus aureus, Bacillus subtilis, Candida albicans and Aspergillus niger. During simulation relative humidity under the facepiece increased after 7 min of usage to 84%–92% and temperature increased to 29–30 °C. S. aureus survived the best on filter materials with 40%–200% moisture content. A decrease in survivability was observed for E. coli and C. albicans when mass humidity decreased. We found that B. subtilis and A. niger proliferated for 48–72 h of incubation and then died regardless of the moisture content. In conclusion, our tests showed that the survivability of microorganisms on filter materials depends on the amount of accumulated moisture and microorganism type.

  8. Evaluation of the Survivability of Microorganisms Deposited on Filtering Respiratory Protective Devices under Varying Conditions of Humidity.

    Science.gov (United States)

    Majchrzycka, Katarzyna; Okrasa, Małgorzata; Skóra, Justyna; Gutarowska, Beata

    2016-01-04

    Bioaerosols are common biological factors in work environments, which require routine use of filtering respiratory protective devices (FRPDs). Currently, no studies link humidity changes in the filter materials of such devices, during use, with microorganism survivability. Our aim was to determine the microclimate inside FRPDs, by simulating breathing, and to evaluate microorganism survivability under varying humidity conditions. Breathing was simulated using commercial filtering facepiece respirators in a model system. Polypropylene melt-blown nonwoven fabrics with moisture contents of 40%, 80%, and 200%, were used for assessment of microorganisms survivability. A modified AATCC 100-2004 method was used to measure the survivability of ATCC and NCAIM microorganisms: Escherichia coli, Staphylococcus aureus, Bacillus subtilis, Candida albicans and Aspergillus niger. During simulation relative humidity under the facepiece increased after 7 min of usage to 84%-92% and temperature increased to 29-30 °C. S. aureus survived the best on filter materials with 40%-200% moisture content. A decrease in survivability was observed for E. coli and C. albicans when mass humidity decreased. We found that B. subtilis and A. niger proliferated for 48-72 h of incubation and then died regardless of the moisture content. In conclusion, our tests showed that the survivability of microorganisms on filter materials depends on the amount of accumulated moisture and microorganism type.

  9. Effects of Active and Passive Hearing Protection Devices on Sound Source Localization, Speech Recognition, and Tone Detection.

    Directory of Open Access Journals (Sweden)

    Andrew D Brown

    Full Text Available Hearing protection devices (HPDs such as earplugs offer to mitigate noise exposure and reduce the incidence of hearing loss among persons frequently exposed to intense sound. However, distortions of spatial acoustic information and reduced audibility of low-intensity sounds caused by many existing HPDs can make their use untenable in high-risk (e.g., military or law enforcement environments where auditory situational awareness is imperative. Here we assessed (1 sound source localization accuracy using a head-turning paradigm, (2 speech-in-noise recognition using a modified version of the QuickSIN test, and (3 tone detection thresholds using a two-alternative forced-choice task. Subjects were 10 young normal-hearing males. Four different HPDs were tested (two active, two passive, including two new and previously untested devices. Relative to unoccluded (control performance, all tested HPDs significantly degraded performance across tasks, although one active HPD slightly improved high-frequency tone detection thresholds and did not degrade speech recognition. Behavioral data were examined with respect to head-related transfer functions measured using a binaural manikin with and without tested HPDs in place. Data reinforce previous reports that HPDs significantly compromise a variety of auditory perceptual facilities, particularly sound localization due to distortions of high-frequency spectral cues that are important for the avoidance of front-back confusions.

  10. Radiation beans characterization and implantation for study of lead equivalent individual protection device used in radiodiagnostic practices

    International Nuclear Information System (INIS)

    Pereira, Leslie Silva

    2004-01-01

    The protective shielding (IPC) must be used by occupationally exposed professionals, patients and volunteers, in order to optimize the doses who receive due to radiological practices. International and national norms establish the methodology to be adopted for determination of the IPC attenuation. In this work, the IPC had been submitted to X-rays beams with known characteristics, standardized for determination of their attenuation equivalent thickness by comparison to an experimental lead attenuation slope. This comparison technique allowed insurance estimative of the IPC attenuation equivalent thickness in mm of lead. Thus, it was possible to verify the conformity of the attenuation equivalent thickness determined experimentally and the value of the thickness indicated by the manufacturer. To carry out this work, it was necessary the implementation of experimental setups stated in the specifics norms, the study of the X-rays beams original features and the determination of combined additional filters, in order to allow the X-ray equipment used operates in compliance with Norm IEC 61331-1 IEC. The radiation quality selected is characterized by a 100 kV voltage and a 0.25 mm of copper overall filtration. The implementation of this radiation quality it was carried through of its first and second HVL (Half Value Layer). Thus, a methodology according to the international Norms has been implemented in the laboratory. The results of the present work provide suitable and useful information about radiation beams features related to the determination techniques of the attenuation properties. Once implemented the procedures for conformity evaluation of the protection devices, it will be possible to carry out specific quality control tests, which will be helpful to manufacturers, customers, as well as authorities in the radiological protection and health areas. (author)

  11. Proposal for the award of a blanket order contract for the supply of microprocessor-based protection and control devices for the CERN HV distribution network

    CERN Document Server

    2004-01-01

    This document concerns the award of a blanket contract for the supply of microprocessor-based protection and control devices for the CERN HV distribution network. The Finance Committee is invited to agree to the negotiation of a blanket order contract with SCHNEIDER ELECTRIC (PT), the lowest technically acceptable bidder after realignment, for the supply of microprocessor-based protection and control devices for the CERN HV distribution network for a total amount of 1 900 000 euros (2 924 128 Swiss francs), subject to revision for inflation after 1 January 2007. The rate of exchange used is that stipulated in the tender

  12. Study of performance of acoustic fixture for using in noise reduction rate tests of hearing protection devices

    Directory of Open Access Journals (Sweden)

    zam Biabani

    2016-06-01

    Full Text Available Introduction:One of the recommended methods for evaluation effectiveness of hearing protection is use the acoustic fixture accordance with standard ISO 4869-3. The aim of this study was evaluate the acoustic performance of fixture for using in noise reduction rate tests of hearing protection devices in the laboratory. Methods: In this cross-sectional study , noise reduction rates of five common ear muffs used in the Iran industries were investigated based on the ISO 11904 standard, microphone in real ear method, using noise dosimeter (SVANTEK , Model SV102 equipped with microphone SV25 model which can install inside the ear on 30 subjects under laboratory conditions. Also, noise reduction rate of earmuffs was determined using the fixture model AVASINA9402 accordance with standard procedures. Data were analyzed using the software SPSS21. Results: The results showed the real noise reduction rates of the earmuffs on the studied subjects are from 59% to 94% nominal reduction rates. That rates for the ear muffs on the studied fixture are from 64% to 92.The results showed that the noise reduction rates of the ear muffs on subjects compared with and noise reduction rates of the ear muffs on fixture were not statistically significant (p> 0.05. Conclusion: The results showed the accuracy of noise reduction rate of earmuffs using the fixture compared with real subjects is acceptable. Hence, the fixture is good choice for environments where there’s no possibility of acoustic evaluation on real subjects, also for quality control of productions in the earmuff manufacturers.

  13. Modeling Speech Level as a Function of Background Noise Level and Talker-to-Listener Distance for Talkers Wearing Hearing Protection Devices

    Science.gov (United States)

    Bouserhal, Rachel E.; Bockstael, Annelies; MacDonald, Ewen; Falk, Tiago H.; Voix, Jérémie

    2017-01-01

    Purpose: Studying the variations in speech levels with changing background noise level and talker-to-listener distance for talkers wearing hearing protection devices (HPDs) can aid in understanding communication in background noise. Method: Speech was recorded using an intra-aural HPD from 12 different talkers at 5 different distances in 3…

  14. Directive of the Minister of Public Health and Environmental Protection of 14 October 1975, Stcrt. 203 in implementation of Section 28 of the Nuclear Energy Act (Devices) Decree

    International Nuclear Information System (INIS)

    1975-01-01

    This Directive lays down the procedure for applications for licences under the Devices Decree. The competent authority in this respect is the Minister of Public Health and Environmental Protection, formerly the State Secretary for Social Affairs and Public Health. (NEA) [fr

  15. Final Results of the Protected Superficial Femoral Artery Trial Using the FilterWire EZ System

    International Nuclear Information System (INIS)

    Mueller-Huelsbeck, Stefan; Huemme, Tim H.; Philipp Schaefer, J.; Charalambous, Nikolas; Paulsen, Friedrich; Heller, Martin; Jahnke, Thomas

    2010-01-01

    The purpose of this study was to evaluate the safety and efficacy of debris-capture for distal protection using the FilterWire EZ Embolic Protection System (Boston Scientific, Mountain View, CA) with the additional aim to further define the incidence of distal embolization during superficial femoral artery (SFA) interventions. A prospective, single-centre registry was designed to evaluate the performance of the FilterWire EZ in capturing debris during standard SFA percutaneous intervention. The PRO-RATA study included 30 patients suitable for PTA (Fontaine IIb to III or Rutherford I to II classification). The primary end points were occurrence of distal embolization or decreased runoff, improvement in ankle-brachial index ankle-brachial index (ABI) after the procedure, and number of filters containing emboli. Secondary end points included major adverse events (i.e., procedure- or device-related death and/or clinical target lesion revascularisation), device delivery, deployment success, and incidence of embolic recovery (patients with device success exhibiting embolic protection in the filter). Procedural success was determined as ≤30% residual stenosis with no worsening of distal runoff as determined on angiography. A total of 29 patients (age 66.2 ± 12 years; total no. of limbs = 30; total no. of lesions = 30) suitable for PTA were enrolled in the study between February 2007 and March 2008. There were 26 patients with claudication (Fontaine IIB) and 3 patients with stage IV peripheral vascular disease. In one patient, lesions in both legs were treated. No procedural or device-related complications occured. The average degree of stenosis was 86 ± 7%. Stenosis length ranged from 8 to 88 mm. The average degree of residual stenosis was 10 ± 10%. ABI improved from 0.56 ± 0.16 to 0.92 ± 0.19 (P < 0.05). No restenosis or dissection was seen at 1-month ultrasound follow-up. Macroscopic debris was found in 27 of 30 filters of all distal protection devices used in

  16. Effects of low speed wind on the recognition/identification and pass-through communication tasks of auditory situation awareness afforded by military hearing protection/enhancement devices and tactical communication and protective systems.

    Science.gov (United States)

    Lee, Kichol; Casali, John G

    2016-01-01

    To investigate the effect of controlled low-speed wind-noise on the auditory situation awareness performance afforded by military hearing protection/enhancement devices (HPED) and tactical communication and protective systems (TCAPS). Recognition/identification and pass-through communications tasks were separately conducted under three wind conditions (0, 5, and 10 mph). Subjects wore two in-ear-type TCAPS, one earmuff-type TCAPS, a Combat Arms Earplug in its 'open' or pass-through setting, and an EB-15LE electronic earplug. Devices with electronic gain systems were tested under two gain settings: 'unity' and 'max'. Testing without any device (open ear) was conducted as a control. Ten subjects were recruited from the student population at Virginia Tech. Audiometric requirements were 25 dBHL or better at 500, 1000, 2000, 4000, and 8000 Hz in both ears. Performance on the interaction of communication task-by-device was significantly different only in 0 mph wind speed. The between-device performance differences varied with azimuthal speaker locations. It is evident from this study that stable (non-gusting) wind speeds up to 10 mph did not significantly degrade recognition/identification task performance and pass-through communication performance of the group of HPEDs and TCAPS tested. However, the various devices performed differently as the test sound signal speaker location was varied and it appears that physical as well as electronic features may have contributed to this directional result.

  17. Limited open reduction is better for simple- distal tibial shaft fractures than minimally invasive plate osteosynthesis.

    Science.gov (United States)

    Li, Q; Zeng, B F; Luo, C F; Song, S; Zhang, C Q; Kong, W Q

    2014-07-24

    The aim of this study was to compare the effects and indications of minimally invasive plate osteosynthesis (MIPO) and limited open reduction (LOR) for managing distal tibial shaft fractures. A total of 79 cases of distal tibial shaft fractures were treated surgically in our trauma center. The 79 fracture cases were classified into type A, B, and C (C1) according to the Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification, with 28, 32, and 19 cases, respectively. Among the 79 fracture cases, 52 were closed fractures and 27 were open fractures (GUSTILO, I-II). After adequate preparation, 48 cases were treated with LOR and 31 cases were treated with MIPO. All cases were followed up for 12 to 18 months, with an average of 16.4 months. During the follow-up period, 76 fracture cases were healed in the first stage, whereas the 3 cases that developed non-union were treated by changing the fixation device and autografting. For types A, B, and some of C simple fractures (C1), LOR accelerated the fracture healing and lowered the non-union rate. One case suffered from regional soft tissue infection, which was controlled by wound dressing and intravenous antibiotics. Another case that developed local skin necrosis underwent local flap transplant. LOR promoted bone healing and lowered the non-union rate of several simple-distal tibial shaft fractures. Thereafter, the incidence of soft tissue complication was not significantly increased. However, for complex and comminuted fractures, MIPO was the preferred method for correcting bone alignment and protecting soft tissue, leading to functional recovery.

  18. Embolic Protection using the WIRION Embolic Protection System with JetStream Atherectomy in a Patient with Superficial Femoral Artery Chronic total Occlusion.

    Science.gov (United States)

    Shammas, Nicolas W

    2017-06-01

    Distal embolization is a common occurrence with peripheral arterial interventions and is more frequent with the use of atherectomy devices. We report the first case of JetStream atherectomy (Boston Scientific, Maple Grove, MN) with the use of the novel WIRION embolic protection system filter. The procedure was performed successfully with no distal embolizations beyond the filter and with no complications in the delivery or retrieval of the filter. The pros and cons of the off label use of this filter with JetStream atherectomy are discussed.

  19. Cerebral ischemia after filter-protected carotid artery stenting is common and cannot be predicted by the presence of substantial amount of debris captured by the filter device.

    Science.gov (United States)

    Maleux, G; Demaerel, P; Verbeken, E; Daenens, K; Heye, S; Van Sonhoven, F; Nevelsteen, A; Wilms, G

    2006-10-01

    Protected carotid artery stent placement is currently under clinical evaluation as a potential alternative to carotid endarterectomy. The current study was undertaken to determine the incidence of new ischemic lesions found on diffusion-weighted MR imaging (DWI) in nonselected patients after protected carotid artery stent placement using a filter device and to determine the potential relationship between these new ischemic lesions and the presence or absence of a clear amount of debris captured by the neuroprotection filter device. A nonrandomized cohort of 52 patients (40 men, 12 women) presenting with carotid occlusive disease underwent protected carotid artery stent placement using a filter device. DWI obtained 1 day before stent placement was compared with that obtained 1 day after stent placement. In addition, the macroscopic and microscopic analysis of debris captured by the filter device during the carotid stent placement procedure was assessed. Neuroprotected carotid stent placement was technically successful in all 53 procedures but was complicated by a transient ischemic attack in 3 patients (5.6%). In 22 patients (41.5%), new ischemic lesions were found on DWI, and in 21 filter devices (39.6%), a substantial amount of atheromatous plaque and/or fibrin was found. No clear relationship between the presence of debris captured by the filter device and new lesions detected by DWI was found (P = .087; odds ratio 3.067). Neuroprotected carotid artery stent placement will not avoid silent cerebral ischemia. Systematic microscopic analysis of debris captured by the filter device has no predictive value for potential cerebral ischemia after carotid artery stent placement.

  20. Spleen-preserving distal pancreatectomy in trauma.

    Science.gov (United States)

    Schellenberg, Morgan; Inaba, Kenji; Cheng, Vincent; Bardes, James M; Lam, Lydia; Benjamin, Elizabeth; Matsushima, Kazuhide; Demetriades, Demetrios

    2018-01-01

    Traumatic injuries to the distal pancreas are infrequent. Universally accepted recommendations about the need for routine splenectomy with distal pancreatectomy do not exist. The aims of this study were to compare outcomes after distal pancreatectomy and splenectomy versus spleen-preserving distal pancreatectomy, and to define the appropriate patient population for splenic preservation. All patients who underwent distal pancreatectomy (January 1, 2007, to December 31, 2014) were identified from the National Trauma Data Bank. Patients with concomitant splenic injury and those who underwent partial splenectomy were excluded. Demographics, clinical data, procedures, and outcomes were collected. Study groups were defined by surgical procedure: distal pancreatectomy and splenectomy versus spleen-preserving distal pancreatectomy. Baseline characteristics between groups were compared with univariate analysis. Multivariate analysis was performed with logistic and linear regression to examine differences in outcomes. Over the 8-year study period, 2,223 patients underwent distal pancreatectomy. After excluding 1,381 patients with concomitant splenic injury (62%) and 8 (pancreatectomy and splenectomy, those who underwent spleen-preserving distal pancreatectomy were younger (p pancreatectomy (p = 0.017). Complications, mortality, and intensive care unit LOS were not significantly different. In young patients after blunt trauma who are not severely injured, a spleen-preserving distal pancreatectomy should be considered to allow for conservation of splenic function and a shorter hospital LOS. In all other patients, the surgeon should not hesitate to remove the spleen with the distal pancreas. Therapy, level IV.

  1. Exposure to hazardous workplace noise and use of hearing protection devices among US workers--NHANES, 1999-2004.

    Science.gov (United States)

    Tak, Sangwoo; Davis, Rickie R; Calvert, Geoffrey M

    2009-05-01

    To estimate the prevalence of workplace noise exposure and use of hearing protection devices (HPDs) at noisy work, NIOSH analyzed 1999-2004 data from the National Health and Nutrition Examination Survey (NHANES). A total of 9,275 currently employed workers aged > or =16 years were included in the weighted analysis. Hazardous workplace noise exposure was defined as self-reported exposure to noise at their current job that was so loud that the respondent had to speak in a raised voice to be heard. Industry and occupation were determined based on the respondent's current place and type of work. Twenty-two million US workers (17%) reported exposure to hazardous workplace noise. The weighted prevalence of workplace noise exposure was highest for mining (76%, SE = 7.0) followed by lumber/wood product manufacturing (55%, SE = 2.5). High-risk occupations included repair and maintenance, motor vehicle operators, and construction trades. Overall, 34% of the estimated 22 million US workers reporting hazardous workplace exposure reported non-use of HPDs. The proportion of noise-exposed workers who reported non-use of HPDs was highest for healthcare and social services (73.7%, SE = 8.1), followed by educational services (55.5%). Hearing loss prevention and intervention programs should be targeted at those industries and occupations identified to have a high prevalence of workplace noise exposure and those industries with the highest proportion of noise-exposed workers who reported non-use of HPDs. Published 2009 Wiley-Liss, Inc.

  2. Exclusion of Atherosclerotic Plaque from the Circulation Using Stent-Grafts: Alternative to Carotid Stenting with a Protection Device?

    International Nuclear Information System (INIS)

    Peynircioglu, Bora; Geyik, Serdar; Yavuz, Kivilcim; Cil, Barbaros E.; Saatci, Isil; Cekirge, Saruhan

    2007-01-01

    Purpose. To retrospectively assess the feasibility, safety, and clinical mid-term outcome of patients undergoing carotid artery stenting with stent-grafts. Methods. Over a 4 year period stent-grafts were used in the endovascular treatment of symptomatic internal carotid artery stenosis in 12 patients (2 women, 10 men, aged 47-83 (mean 64) years). Protection devices were not used. Possible microembolic complications were evaluated by magnetic resonance imaging (MRI) examinations of the brain before and the day after the procedure in all patients. Mean follow-up was 22 months (range 1-42 months), by Doppler ultrasonography and conventional angiography as well as clinical examination .Results. The technical success rate was 100%. A total of 13 coronary stent-grafts were used. The mean stenosis rate (in terms of diameter) was 85% and the mean length of stent-grafts used was 20.9 mm. The mean diameter to which the stent-grafts were dilated was 4.66 mm. In-hospital complications occurred in 1 patient who suffered a minor femoral access hematoma that did not require transfusion or surgical decompression. Post-stenting diffusion-weighted MRI revealed several ipsilateral silent microemboli in only 1 case, which was completely asymptomatic. Two patients had a major stroke after 2 years of follow-up. Restenosis was found in 2 patients who underwent successful balloon dilatation followed by placement of a self-expandable bare stent within the stent-grafts. Conclusions. Stent-grafts may prevent microembolic complications during stenting of atherosclerotic carotid lesions in selected cases, offering immediate exclusion of the atherosclerotic lesion from the circulation by pressing the plaque against the vessel wall. Comparative, randomized studies in larger series of patients are needed with carotid-dedicated stent-graft designs

  3. Portable hyperspectral device as a valuable tool for the detection of protective agents applied on hystorical buildings

    Science.gov (United States)

    Vettori, S.; Pecchioni, E.; Camaiti, M.; Garfagnoli, F.; Benvenuti, M.; Costagliola, P.; Moretti, S.

    2012-04-01

    In the recent past, a wide range of protective products (in most cases, synthetic polymers) have been applied to the surfaces of ancient buildings/artefacts to preserve them from alteration [1]. The lack of a detailed mapping of the permanence and efficacy of these treatments, in particular when applied on large surfaces such as building facades, may be particularly noxious when new restoration treatments are needed and the best choice of restoration protocols has to be taken. The presence of protective compounds on stone surfaces may be detected in laboratory by relatively simple diagnostic tests, which, however, normally require invasive (or micro-invasive) sampling methodologies and are time-consuming, thus limiting their use only to a restricted number of samples and sampling sites. On the contrary, hyperspectral sensors are rapid, non-invasive and non-destructive tools capable of analyzing different materials on the basis of their different patterns of absorption at specific wavelengths, and so particularly suitable for the field of cultural heritage [2,3]. In addition, they can be successfully used to discriminate between inorganic (i.e. rocks and minerals) and organic compounds, as well as to acquire, in short times, many spectra and compositional maps at relatively low costs. In this study we analyzed a number of stone samples (Carrara Marble and biogenic calcarenites - "Lecce Stone" and "Maastricht Stone"-) after treatment of their surfaces with synthetic polymers (synthetic wax, acrylic, perfluorinated and silicon based polymers) of common use in conservation-restoration practice. The hyperspectral device used for this purpose was ASD FieldSpec FR Pro spectroradiometer, a portable, high-resolution instrument designed to acquire Visible and Near-Infrared (VNIR: 350-1000 nm) and Short-Wave Infrared (SWIR: 1000-2500 nm) punctual reflectance spectra with a rapid data collection time (about 0.1 s for each spectrum). The reflectance spectra so far obtained in

  4. Nuclear fast neutron reactor cooled by a liquid metal and of which internal structures are equipped with a thermal protection device

    International Nuclear Information System (INIS)

    Lemercier, G.; Lions, N.

    1986-01-01

    The internal structures of a nuclear fast neutron reactor are covered at least partially, on the most hot side, by a thermal protection device. This device comprises modular plates arranged end to end with a certain play between themselves and taking approximately the shape of the internal structures. Each plate is fixed in its center on the internal structures by a stud. A small plate fixed at one of the corners of each plate and covering partially the adjacent plates ensures the safety fixing of these ones [fr

  5. CT virtual reality in the preoperative workup of malunited distal radius fractures: preliminary results

    International Nuclear Information System (INIS)

    Rieger, Michael; Gruber, Hannes; Jaschke, Werner R.; Gabl, Markus; Mallouhi, Ammar

    2005-01-01

    Our objective was to evaluate the usefulness of CT virtual preoperative planning in the surgical repositioning of malunited distal radius fracture. Eleven patients with malunited distal radius fracture underwent multislice CT of both wrists. A preoperative workup was performed in a virtual reality environment created from the CT data sets. Virtual planning comprised three main procedures, carrying out the virtual osteotomy of the radius, prediction of the final position of the distal radius after osteotomy and computer-assisted manufacturing of a repositioning device, which was later placed at the surgical osteotomy site to reposition objectively the distal radius fragment before fixation with the osteosynthesis. All patients tolerated the surgical procedure well. During surgery, the orthopedic surgeons were not required in any of the cases to alter the position of the distal radius that was determined by the repositioning device. At postoperative follow-up, the anatomic relationship of the distal radius was restored (radial inclination, 21.4 ; volar tilt, 10.3 ; ulnar variance, 0.5 mm). Clinically, a significant improvement of pronation (P=0.012), supination (P=0.01), flexion (P=0.001) and extension (P=0.006) was achieved. Pain decreased from 54 to 7 points. CT virtual reality is a valuable adjunct for the preoperative workup and surgical reposition of malunited distal radius fractures. (orig.)

  6. Professional installation of overvoltage protection devices. The most common installation errors; Fachgerechte Installation von Ueberspannungsschutzgeraeten. Die haeufigsten Installationsfehler

    Energy Technology Data Exchange (ETDEWEB)

    Gmelch, L. [Dehn und Soehne GmbH und Co. KG, Neumarkt (Germany)

    2007-07-01

    Increasingly sensitive electronic equipment and high demands on plant and system availability necesstate effective protection against lightning and overvoltage. Apart from the measures that must be taken already in the projecting phase in order to minimize the risk of interferences, disturbances and destruction of plants and systems, there are also some basic principles that must be observed when installing overvoltage protection equipment. If these are neglected, the protective function of overvoltage protection systems may be seriously impaired. (orig.)

  7. Development of the self-learning machine for creating models of microprocessor of single-phase earth fault protection devices in networks with isolated neutral voltage above 1000 V

    Science.gov (United States)

    Utegulov, B. B.; Utegulov, A. B.; Meiramova, S.

    2018-02-01

    The paper proposes the development of a self-learning machine for creating models of microprocessor-based single-phase ground fault protection devices in networks with an isolated neutral voltage higher than 1000 V. Development of a self-learning machine for creating models of microprocessor-based single-phase earth fault protection devices in networks with an isolated neutral voltage higher than 1000 V. allows to effectively implement mathematical models of automatic change of protection settings. Single-phase earth fault protection devices.

  8. Protective

    Directory of Open Access Journals (Sweden)

    Wessam M. Abdel-Wahab

    2013-10-01

    Full Text Available Many active ingredients extracted from herbal and medicinal plants are extensively studied for their beneficial effects. Antioxidant activity and free radical scavenging properties of thymoquinone (TQ have been reported. The present study evaluated the possible protective effects of TQ against the toxicity and oxidative stress of sodium fluoride (NaF in the liver of rats. Rats were divided into four groups, the first group served as the control group and was administered distilled water whereas the NaF group received NaF orally at a dose of 10 mg/kg for 4 weeks, TQ group was administered TQ orally at a dose of 10 mg/kg for 5 weeks, and the NaF-TQ group was first given TQ for 1 week and was secondly administered 10 mg/kg/day NaF in association with 10 mg/kg TQ for 4 weeks. Rats intoxicated with NaF showed a significant increase in lipid peroxidation whereas the level of reduced glutathione (GSH and the activity of superoxide dismutase (SOD, catalase (CAT, glutathione S-transferase (GST and glutathione peroxidase (GPx were reduced in hepatic tissues. The proper functioning of the liver was also disrupted as indicated by alterations in the measured liver function indices and biochemical parameters. TQ supplementation counteracted the NaF-induced hepatotoxicity probably due to its strong antioxidant activity. In conclusion, the results obtained clearly indicated the role of oxidative stress in the induction of NaF toxicity and suggested hepatoprotective effects of TQ against the toxicity of fluoride compounds.

  9. Pancreatic Tissue Transplanted in TheraCyte Encapsulation Devices Is Protected and Prevents Hyperglycemia in a Mouse Model of Immune-Mediated Diabetes.

    Science.gov (United States)

    Boettler, Tobias; Schneider, Darius; Cheng, Yang; Kadoya, Kuniko; Brandon, Eugene P; Martinson, Laura; von Herrath, Matthias

    2016-01-01

    Type 1 diabetes (T1D) is characterized by destruction of glucose-responsive insulin-producing pancreatic β-cells and exhibits immune infiltration of pancreatic islets, where CD8 lymphocytes are most prominent. Curative transplantation of pancreatic islets is seriously hampered by the persistence of autoreactive immune cells that require high doses of immunosuppressive drugs. An elegant approach to confer graft protection while obviating the need for immunosuppression is the use of encapsulation devices that allow for the transfer of oxygen and nutrients, yet prevent immune cells from making direct contact with the islet grafts. Here we demonstrate that macroencapsulation devices (TheraCyte) loaded with neonatal pancreatic tissue and transplanted into RIP-LCMV.GP mice prevented disease onset in a model of virus-induced diabetes mellitus. Histological analyses revealed that insulin-producing cells survived within the device in animal models of diabetes. Our results demonstrate that these encapsulation devices can protect from an immune-mediated attack and can contain a sufficient amount of insulin-producing cells to prevent overt hyperglycemia.

  10. Systematic review: comparative effectiveness of adjunctive devices in patients with ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention of native vessels

    Directory of Open Access Journals (Sweden)

    Sobieraj Diana M

    2011-12-01

    Full Text Available Abstract Background During percutaneous coronary intervention (PCI, dislodgement of atherothrombotic material from coronary lesions can result in distal embolization, and may lead to increased major adverse cardiovascular events (MACE and mortality. We sought to systematically review the comparative effectiveness of adjunctive devices to remove thrombi or protect against distal embolization in patients with ST-segment elevation myocardial infarction (STEMI undergoing PCI of native vessels. Methods We conducted a systematic literature search of Medline, the Cochrane Database, and Web of Science (January 1996-March 2011, http://www.clinicaltrials.gov, abstracts from major cardiology meetings, TCTMD, and CardioSource Plus. Two investigators independently screened citations and extracted data from randomized controlled trials (RCTs that compared the use of adjunctive devices plus PCI to PCI alone, evaluated patients with STEMI, enrolled a population with 95% of target lesion(s in native vessels, and reported data on at least one pre-specified outcome. Quality was graded as good, fair or poor and the strength of evidence was rated as high, moderate, low or insufficient. Disagreement was resolved through consensus. Results 37 trials met inclusion criteria. At the maximal duration of follow-up, catheter aspiration devices plus PCI significantly decreased the risk of MACE by 27% compared to PCI alone. Catheter aspiration devices also significantly increased the achievement of ST-segment resolution by 49%, myocardial blush grade of 3 (MBG-3 by 39%, and thrombolysis in myocardial infarction (TIMI 3 flow by 8%, while reducing the risk of distal embolization by 44%, no reflow by 48% and coronary dissection by 70% versus standard PCI alone. In a majority of trials, the use of catheter aspiration devices increased procedural time upon qualitative assessment. Distal filter embolic protection devices significantly increased the risk of target revascularization

  11. Posttraumatic osteolysis of the distal clavicula end

    International Nuclear Information System (INIS)

    Hermanns, P.H.; Beeger, R.; Koetter, D.; Hamburg Univ.

    1981-01-01

    Posttraumatic osteolysis of bone is rare. Its etiology is unknown. A case of posttraumatic osteolysis of the distal clavicle end is reported. Differentialdiagnostical and ethiological relations are discussed. The literature of posttraumatic osteolysis especially of distal clavicle osteolysis is reported. (orig.) [de

  12. Contemporary Management of Primary Distal Urethral Cancer

    NARCIS (Netherlands)

    Traboulsi, S.L.; Witjes, J.A.; Kassouf, W.

    2016-01-01

    Primary urethral cancer is one of the rare urologic tumors. Distal urethral tumors are usually less advanced at diagnosis compared with proximal tumors and have a good prognosis if treated appropriately. Low-stage distal tumors can be managed successfully with a surgical approach in men or radiation

  13. Components for containment enclosures. Part 4: Ventilation and gas-cleaning systems such as filters, traps, safety and regulation valves, control and protection devices

    International Nuclear Information System (INIS)

    2001-01-01

    ISO 11933 consists of the following parts, under the general title Components for containment enclosures: Part 1: Glove/bag ports, bungs for glove/bag ports, enclosure rings and interchangeable units; Part 2: Gloves, welded bags, gaiters for remote-handling tongs and for manipulators; Part 3: Transfer systems such as plain doors, airlock chambers, double door transfer systems, leaktight connections for waste drums; Part 4: Ventilation and gas-cleaning systems such as filters, traps, safety and regulation valves, control and protection devices; Part 5: Penetrations for electrical and fluid circuits. This part of ISO 11933 specifies the design criteria and the characteristics of various components used for ventilation and gas-cleaning in containment enclosures. These components are either directly fixed to the containment enclosure wall, or used in the environment of a shielded or unshielded containment enclosure or line of such enclosures. They can be used alone or in conjunction with other mechanical components, including those specified in ISO 11933-1 and ISO 11933-3. This part of ISO 11933 is applicable to: filtering devices, including high-efficiency particulate air (HEPA) filters and iodine traps; safety valves and pressure regulators; systems ensuring the mechanical protection of containment enclosures; control and pressure-measurement devices

  14. IAEA calls for enhanced radiation protection of patients. Safety specialists warn against overuse of new imaging devices

    International Nuclear Information System (INIS)

    2009-01-01

    Advances in medical imaging techniques are allowing doctors to detect hidden diseases and make ever more accurate diagnoses. But radiation safety experts at the International Atomic Energy Agency (IAEA) say that overuse of high-tech scanning procedures may unnecessarily expose patients to increased radiation levels. The IAEA, in collaboration with other international organizations, is developing a series of measures aimed at strengthening patient protection. The focus of recent efforts is a Smart Card project, to log how much radiation a person receives in the course of a lifetime. Concern surrounds procedures such as computed tomography (CT) scans because they deliver higher doses of radiation to patients in comparison to conventional X-rays (radiographs). It's been estimated that the average radiation dose of one CT scan is equal to roughly 500 chest X-rays. And that can increase a patient's lifetime risk of cancer, particularly if CT scans are repeated. The IAEA is one of the key international players in the field of patient radiation protection. A unit dedicated to the Radiological Protection of Patients (RPoP) was established in 2001. The IAEA's activities in radiation protection of patients include training, knowledge sharing and capacity building in the medical use of radiation. Extensive, up-to-date training material for health professionals is freely available on the RPoP website. An International Action Plan on the Radiological Protection of Patients that has been established together with leading international organizations such as the World Health Organization (WHO), UNSCEAR, the International Commission on Radiological Protection (ICRP) and others to identify strategies for strengthening radiation protection of patients. Coordinating and managing technical cooperation projects with Member States on patient dose assessment. The aim is to identify the factors that contribute to unnecessary radiation dose to patients, provide guidance on dealing with

  15. Modeling Speech Level as a Function of Background Noise Level and Talker-to-Listener Distance for Talkers Wearing Hearing Protection Devices

    DEFF Research Database (Denmark)

    Bouserhal, Rachel E.; Bockstael, Annelies; MacDonald, Ewen

    2017-01-01

    Purpose: Studying the variations in speech levels with changing background noise level and talker-to-listener distance for talkers wearing hearing protection devices (HPDs) can aid in understanding communication in background noise. Method: Speech was recorded using an intra-aural HPD from 12...... complements the existing model presented by Pelegrín-García, Smits, Brunskog, and Jeong (2011) and expands on it by taking into account the effects of occlusion and background noise level on changes in speech sound level. Conclusions: Three models of the relationship between vocal effort, background noise...

  16. A PROSPECTIVE STUDY OF DISTAL TIBIAL FRACTURES BY MIPO (LCP

    Directory of Open Access Journals (Sweden)

    Chandra Sekharam Naidu

    2015-05-01

    Full Text Available INTRODUCTION: D istal tibial fractures represent a significant challenge to most of the surgeons even today. They constitute 1 - 10% of all lower extremity fractures . 1 The difficulty in treating the fractures of distal tibial end is exemplif ied by orthopedists, who in the first half of twentieth century, believed these injuries were so severe and fraught with so many complications, that these fractures were deemed not amenable for surgical reconstruction . 2 Conservative treatment by POP cast l ead to prolonged immobilization, leading to ankle and knee stiffness affecting quality of life of the patient . 3 Operative treatment is indicated for most tibial fractures caused by high energy trauma. Operative treatment allows early motion, and avoids sho rtening and other complications associated with prolonged immobilization . 4 The fundamental goal of treatment of distal tibial fractures is restoration of normal or near normal alignment and articular congruity and finally to obtain a well healed fracture; pain free weight bearing ; and functional ROM of ankle joint. For the past decade, plating has been successful in treating complex fractures of the lower extremity especially distal tibia . 5 Conventional ORIF have been associated with complications like infe ction and delayed or non - union due to devitalisation of bony fragments and additional damage to the soft tissues . 6 To improve fracture healing, more “biological” methods have been developed in the last decade to lessen the surgical dissection, preserving b lood supply to bony fragments and containing at least partially the fracture haematoma . 7 Recently, the trend is towards use of a Locking compression plate for treatment of fractures of the distal part of the tibia 8 . Compared with a conventional plate, a Lo cking compression plate imparts a higher degree of stability and provides better protection against primary and secondary losses of reduction and minimization of bone

  17. A Novel Technique Using a Protection Filter During Fibrin Sheath Removal for Implanted Venous Access Device Dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Sotiriadis, Charalampos; Hajdu, Steven David [University Hospital of Lausanne, Cardiothoracic and Vascular Unit, Department of Radiology (Switzerland); Degrauwe, Sophie [University Hospital of Lausanne, Department of Cardiology (Switzerland); Barras, Heloise; Qanadli, Salah Dine, E-mail: salah.qanadli@chuv.ch [University Hospital of Lausanne, Cardiothoracic and Vascular Unit, Department of Radiology (Switzerland)

    2016-08-15

    With the increased use of implanted venous access devices (IVADs) for continuous long-term venous access, several techniques such as percutaneous endovascular fibrin sheath removal, have been described, to maintain catheter function. Most standard techniques do not capture the stripped fibrin sheath, which is subsequently released in the pulmonary circulation and may lead to symptomatic pulmonary embolism. The presented case describes an endovascular technique which includes stripping, capture, and removal of fibrin sheath using a novel filter device. A 64-year-old woman presented with IVAD dysfunction. Stripping was performed using a co-axial snare to the filter to capture the fibrin sheath. The captured fragment was subsequently removed for visual and pathological verification. No immediate complication was observed and the patient was discharged the day of the procedure.

  18. Device for protecting the section of the airline electricity transmission with insulated neutral from incomplete phase modes

    Energy Technology Data Exchange (ETDEWEB)

    Sagutdinov, R.Sh.; Batoyev, D.

    1982-01-01

    The device for USSR certificate of authorship 792439 is improved in order to raise reliability of isolating the damage zone by including into operation an antenna filter for voltage of zero sequence (AFNIP) only during the operating time of the electrical unit in incomplete phase mode. The newly introduced circuit breaker contract of the inlet relay of the voltage filter for reverse sequence is connected between the outlet of the AFNIP and the ground. The device additionally has a time relay which is connected to the outlet of the voltage filter of reverse sequence. The circuit breaker contact of the inlet relay AFNIP is connected in series to the closure contact of the time relay and the winding of the second outlet relay of the actuating mechanism.

  19. Metoda ispitivanja kompatibilnosti sredstava lične NHB zaštite / Method of testing compatibility of personal NBC protection devices

    Directory of Open Access Journals (Sweden)

    Dušan Rajić

    2009-07-01

    Full Text Available Na primeru izabranih sredstava lične NHB zaštite demonstrirana je primena metode procene kompatibilnosti, kao vrlo bitne taktičko-tehničke karakteristike za svako novouvedeno sredstvo naoružanja i vojne opreme (NVO u Vojsci Srbije. Utvrđeno je da zaštitno filtrirajuće odelo, zaštitni laki ogrtač i zaštitne rukavice ispunjavaju postavljene kriterijume kompatibilnosti. Opisana metoda provere kompatibilnosti može da se primenjuje i na druga sredstva NVO u fazama razvoja, proizvodnje i eksploatacije. / The selected personal NBC protection devices have served as an example for demonstrating the application of the compatibility evaluation method as a very important tactical-technical characteristic of each newly introduced item of weapon and military equipment in the Serbian army. It has been determined that a filtering protective suit, a light protective coat and protective gloves meet the required criteria of compatibility. The described method of testing compatibility can be also applied to other weapons and military equipment in stages of development, production and exploitation.

  20. Can Smartphones and Privacy Coexist Assessing Technologies and Regulations Protecting Personal Data on Android and iOS Devices

    Science.gov (United States)

    2016-01-01

    from unknown sources even if they have not been approved for the app store (“Google Report: Android Security 2014 Year in Review,” 2014). This makes...Report: Android Security 2014 Year in Review,” 2014. As of October 2015: https://static.googleusercontent.com/media/source.android.com/ en//devices...Experience Returns for Security (BADGERS), September 11, 2014. Lockheimer, Hiroshi, “ Android and Security ,” Google Mobile Blog, February 2, 2012. As

  1. Development of a test device to characterize thermal protective performance of fabrics against hot steam and thermal radiation

    International Nuclear Information System (INIS)

    Su, Yun; Li, Jun

    2016-01-01

    Steam burns severely threaten the life of firefighters in the course of their fire-ground activities. The aim of this paper was to characterize thermal protective performance of flame-retardant fabrics exposed to hot steam and low-level thermal radiation. An improved testing apparatus based on ASTM F2731-11 was developed in order to simulate the routine fire-ground conditions by controlling steam pressure, flow rate and temperature of steam box. The thermal protective performance of single-layer and multi-layer fabric system with/without an air gap was studied based on the calibrated tester. It was indicated that the new testing apparatus effectively evaluated thermal properties of fabric in hot steam and thermal radiation. Hot steam significantly exacerbated the skin burn injuries while the condensed water on the skin’s surface contributed to cool down the skin tissues during the cooling. Also, the absorbed thermal energy during the exposure and the cooling was mainly determined by the fabric’s configuration, the air gap size, the exposure time and the existence of hot steam. The research provides a effective method to characterize the thermal protection of fabric in complex conditions, which will help in optimization of thermal protection performance of clothing and reduction of steam burn. (paper)

  2. Electromagnetic Pulse/Transient Threat Testing of Protection Devices for Amateur/Military Affiliate Radio System Equipment. Volume 2

    Science.gov (United States)

    1985-10-31

    4-45 4-1 SPC =. NTiC)NS I SPIKEGUARD SUPPRESSORS NANOSECOND TRANSIENT PROTECTION MODELS AVAILABLE FOR ,u * COAXIAL LINES...molded epoxy casc 4-40 General1- ~ *Sewiconductor4*industries,, Inc. Squats D oE.!v! MAXIMUM RATINGS DESCRIPTION coNro CASE 19 * Steady State POWr I

  3. Conceptualizing distal drivers in land use competition

    DEFF Research Database (Denmark)

    Niewhöner, Jörg; Nielsen, Jonas Ø; Gasparri, Gasparri

    2016-01-01

    This introductory chapter explores the notion of ‘distal drivers’ in land use competition. Research has moved beyond proximate causes of land cover and land use change to focus on the underlying drivers of these dynamics. We discuss the framework of telecoupling within human–environment systems...... as a first step to come to terms with the increasingly distal nature of driving forces behind land use practices. We then expand the notion of distal as mainly a measure of Euclidian space to include temporal, social, and institutional dimensions. This understanding of distal widens our analytical scope...... for the analysis of land use competition as a distributed process to consider the role of knowledge and power, technology, and different temporalities within a relational or systemic analysis of practices of land use competition. We conclude by pointing toward the historical and social contingency of land use...

  4. Distal technologies and type 1 diabetes management.

    Science.gov (United States)

    Duke, Danny C; Barry, Samantha; Wagner, David V; Speight, Jane; Choudhary, Pratik; Harris, Michael A

    2018-02-01

    Type 1 diabetes requires intensive self-management to avoid acute and long-term health complications. In the past two decades, substantial advances in technology have enabled more effective and convenient self-management of type 1 diabetes. Although proximal technologies (eg, insulin pumps, continuous glucose monitors, closed-loop and artificial pancreas systems) have been the subject of frequent systematic and narrative reviews, distal technologies have received scant attention. Distal technologies refer to electronic systems designed to provide a service remotely and include heterogeneous systems such as telehealth, mobile health applications, game-based support, social platforms, and patient portals. In this Review, we summarise the empirical literature to provide current information about the effectiveness of available distal technologies to improve type 1 diabetes management. We also discuss privacy, ethics, and regulatory considerations, issues of global adoption, knowledge gaps in distal technology, and recommendations for future directions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Genetics Home Reference: distal arthrogryposis type 1

    Science.gov (United States)

    ... 1 is a disorder characterized by joint deformities (contractures) that restrict movement in the hands and feet. ... distal arthrogryposis type 1 . However, researchers speculate that contractures may be related to problems with muscle contraction ...

  6. Potassium secretion in mammalian distal colon

    DEFF Research Database (Denmark)

    Sørensen, Mads Vaarby

    2009-01-01

    Epithelial organs adjust the „inner milieu“ of the body and are crucial for all homeostatic processes. Epithelial transport of different solutes and water is regulated phenomena. The regulation processes include both long term hormonal regulation and short term local agonist mediated regulation....... This research project is the summary of 3 original papers addressing the functional role of different regulating factors on ion transport in mouse distal colon. The first paper addresses the effect of luminal nucleotides on electrogenic Na+ absorption. The distal colon, like the distal nephron is an aldosterone......-sensitive tissue and participates in the regulation of Na+ excretion. In the distal nephron it was found that luminal nucleotides inhibit ENaC-mediated Na+ absorption. Here it was addressed whether luminal nucleotides regulate Na+ absorption and if so, which of the known luminal P2 receptors are involved. Using...

  7. Normal distal pulmonary vein anatomy

    Directory of Open Access Journals (Sweden)

    Wiesława Klimek-Piotrowska

    2016-01-01

    Full Text Available Background. It is well known that the pulmonary veins (PVs, especially their myocardial sleeves play a critical role in the initiation and maintenance of atrial fibrillation. Understanding the PV anatomy is crucial for the safety and efficacy of all procedures performed on PVs. The aim of this study was to present normal distal PV anatomy and to create a juxtaposition of all PV ostium variants.Methods. A total of 130 randomly selected autopsied adult human hearts (Caucasian were examined. The number of PVs ostia was evaluated and their diameter was measured. The ostium-to-last-tributary distance and macroscopic presence of myocardial sleeves were also evaluated.Results. Five hundred forty-one PV ostia were identified. Four classical PV ostia patterns (two left and two right PVs were observed in 70.8% of all cases. The most common variant was the classical pattern with additional middle right PV (19.2%, followed by the common ostium for the left superior and the inferior PVs (4.44%. Mean diameters of PV ostia (for the classical pattern were: left superior = 13.8 ± 2.9 mm; left inferior = 13.3 ± 3.4 mm; right superior = 14.3 ± 2.9 mm; right inferior = 13.7 ± 3.3 mm. When present, the additional middle right PV ostium had the smallest PV ostium diameter in the heart (8.2 ± 4.1 mm. The mean ostium-to-last-tributary (closest to the atrium distances were: left superior = 15.1 ± 4.6 mm; left inferior = 13.5 ± 4.0 mm; right superior = 11.8 ± 4.0 mm; right inferior = 11.0 ± 3.7 mm. There were no statistically significant differences between sexes in ostia diameters and ostium-to-last-tributary distances.Conclusion. Only 71% of the cases have four standard pulmonary veins. The middle right pulmonary vein is present in almost 20% of patients. Presented data can provide useful information for the clinicians during interventional procedures or radiologic examinations of PVs.

  8. Revascularization for critical limb ischemia using the SpiderFX embolic protection device in the below-the-knee circulation: initial results.

    Science.gov (United States)

    Ward, Thomas J; Piechowiak, Rachel L; Patel, Rahul S; Fischman, Aaron M; Nowakowski, F Scott; Kim, Edward; Ellozy, Sharif H; Faries, Peter L; Lookstein, Robert A

    2014-10-01

    To examine the safety and efficacy of the SpiderFX embolic protection device (EPD) in the below-the-knee (BTK) circulation in patients with critical limb ischemia (CLI). A single-center retrospective review was performed to identify patients with CLI and single-vessel runoff in whom the SpiderFX EPD was used in the BTK circulation. Technical success and device-related complications were the primary endpoints. Retrieval of macroscopic debris in the EPD, 1-year freedom from major adverse limb events (MALEs), and 30-day perioperative death were also evaluated. A major amputation, surgical bypass, endovascular thrombectomy, or endovascular thrombolysis was considered a MALE. Thirty-six patients (21 men; mean age, 75.8 y) treated between 2008 and 2013 had endovascular revascularization with use of the SpiderFX EPD in the BTK circulation. The SpiderFX EPD was successfully deployed in all cases; the technical success rate of revascularization was 100%. Two minor and zero major complications were observed related to the SpiderFX. Two MALEs, a major amputation and a subsequent surgical bypass, were observed in the cohort. All MALEs occurred within 1 year of treatment (1-y freedom from MALE rate, 90%). Debris was retrieved in the SpiderFX device in 47% of patients. The use of the SpiderFX EPD in the BTK circulation in patients with CLI is safe and frequently retrieves debris. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  9. Computer-assisted surgery for screw insertion into the distal sesamoid bone in horses: an in vitro study.

    Science.gov (United States)

    Gygax, Diego; Lischer, Christoph; Auer, Joerg A

    2006-10-01

    To compare the precision of computer-assisted surgery with a conventional technique (CV) using a special guiding device for screw insertion into the distal sesamoid bone in horses. In vitro experimental study. Cadaveric forelimb specimens. Insertion of a 3.5 mm cortex screw in lag fashion along the longitudinal axis of intact (non-fractured) distal sesamoid bones was evaluated in 2 groups (8 limbs each): CV and computer-assisted surgery (CAS). For CV, the screw was inserted using a special guiding device and fluoroscopy, whereas for CAS, the screw was inserted using computer-assisted navigation. The accuracy of screw placement was verified by radiography, computed tomography, and specimen dissection. Surgical precision was better in CAS compared with CV. CAS improves the accuracy of lateromedial screw insertion, in lag fashion, into the distal sesamoid bone. The CAS technique should be considered for improved accuracy of screw insertion in fractures of the distal sesamoid bone.

  10. Electrochemical device

    Science.gov (United States)

    Grimes, Patrick G.; Einstein, Harry; Bellows, Richard J.

    1988-01-12

    A tunnel protected electrochemical device features channels fluidically communicating between manifold, tunnels and cells. The channels are designed to provide the most efficient use of auxiliary power. The channels have a greater hydraulic pressure drop and electrical resistance than the manifold. This will provide a design with the optimum auxiliary energy requirements.

  11. Study of protection devices against the effects of electric discharges inside a very high voltage generator: the Vivitron accelerator

    International Nuclear Information System (INIS)

    Nolot, E.

    1996-01-01

    The Vivitron tandem is a large electrostatic accelerator comprising a Van de Graaff generator designed to reach terminal voltages of around 30 MV. The machine is limited at rather lower nominal voltages (about 20 MV) due to the sensitivity of the insulating column structure to transient overvoltages. These are induced by electrical discharges in compressed SF 6 . This thesis first aims at analysing the fundamental reasons of electrical discharges in order to limit the probability of their occurrence. Then we simulate the transient overvoltages induced and present some improvements which may lead to a stable behaviour of the Vivitron at nominal voltages higher than 20 MV. Initially we deduce discharge onset voltages and actual breakdown field limitations in the different gap geometries from analysis of possible breakdown mechanisms in compressed SF 6 . In a second part, some electrical characteristics of the insulating column structure are measured at high voltage. Fast rising oscillating waves induced by sparking in the Vivitron, along with the associated energies,are determined in the third part. The last part deals with new surge protections of the insulating column structure. Spark gaps with precise onset voltage and optimized shielding electrodes are discussed. ZnO-based varistors designed for operation at very high fields have also been developed in order to reduce transient overvoltage values. (author)

  12. Methods for the Application of Programmable Logic Devices in Electronic Protection Systems for High Energy Particle Accelerators

    CERN Document Server

    Kwiatkowski, Maciej; Todd, Benjamin

    The present thesis was realised within the framework of the Doctoral Student programme at the European Organisation for Nuclear Research CERN, which is situated near Geneva. The aim of this thesis was to develop a method for reliable firmware implementation and to use that method to implement a new firmware for the Safe Machine Parameters (SMP) system. That system relies heavily on the Field Programmable Gate Arrays (FPGA) and it is one of the key machine protection systems of the Large Hadron Collider (LHC). The conception of the SMP hardware originates from the fully tested Beam Interlock System (BIS) being a result of another PhD thesis. For that reason the reliable SMP hardware was preserved unchanged. The first version of the SMP was ready for the LHC startup in the year 2008. Nevertheless the quality of the SMP firmware was objectionable. There were new requirements and therefore the SMP specification was extended. On that occasion it was decided that the existing SMP firmware will not be continued and ...

  13. Methods for the application of programmable logic devices in electronic protection systems for high energy particle accelerators

    CERN Document Server

    Kwiatkowski, M

    2014-01-01

    The present thesis was realised within the framework of the Doctoral Student programme at the European Organisation for Nuclear Research CERN, which is situated near Geneva. The aim of this thesis was to develop a method for reliable rmware implementation and to use that method to implement a new rmware for the Safe Machine Parameters (SMP) system. That system relies heavily on the Field Programmable Gate Arrays (FPGA) and it is one of the key machine protection systems of the Large Hadron Collider (LHC). The conception of the SMP hardware originates from the fully tested Beam Interlock System (BIS) being a result of another PhD thesis [1]. For that reason the reliable SMP hardware was preserved unchanged. The rst version of the SMP was ready for the LHC startup in the year 2008. Nevertheless the quality of the SMP rmware was objectionable. There were new requirements and therefore the SMP speci cation was extended. On that occasion it was decided that the existing SMP rmware will not be continued and that it...

  14. A Comprehensive Reanalysis of the Distal Iliotibial Band: Quantitative Anatomy, Radiographic Markers, and Biomechanical Properties.

    Science.gov (United States)

    Godin, Jonathan A; Chahla, Jorge; Moatshe, Gilbert; Kruckeberg, Bradley M; Muckenhirn, Kyle J; Vap, Alexander R; Geeslin, Andrew G; LaPrade, Robert F

    2017-09-01

    The qualitative anatomy of the distal iliotibial band (ITB) has previously been described. However, a comprehensive characterization of the quantitative anatomic, radiographic, and biomechanical properties of the Kaplan fibers of the deep distal ITB has not yet been established. It is paramount to delineate these characteristics to fully understand the distal ITB's contribution to rotational knee stability. Purpose/Hypothesis: There were 2 distinct purposes for this study: (1) to perform a quantitative anatomic and radiographic evaluation of the distal ITB's attachment sites and their relationships to pertinent osseous and soft tissue landmarks, and (2) to quantify the biomechanical properties of the deep (Kaplan) fibers of the distal ITB. It was hypothesized that the distal ITB has definable parameters concerning its anatomic attachments and consistent relationships to surgically pertinent landmarks with correlating plain radiographic findings. In addition, it was hypothesized that the biomechanical properties of the Kaplan fibers would support their role as important restraints against internal rotation. Descriptive laboratory study. Ten nonpaired, fresh-frozen human cadaveric knees (mean age, 61.1 years; range, 54-65 years) were dissected for anatomic and radiographic purposes. A coordinate measuring device quantified the attachment areas of the distal ITB to the distal femur, patella, and proximal tibia and their relationships to pertinent bony landmarks. A radiographic analysis was performed by inserting pins into the attachment sites of relevant anatomic structures to assess their location relative to pertinent bony landmarks with fluoroscopic guidance. A further biomechanical assessment of 10 cadaveric knees quantified the load to failure and stiffness of the Kaplan fibers' insertion on the distal femur after a preconditioning protocol. Two separate deep (Kaplan) fiber bundles were identified with attachments to 2 newly identified femoral bony prominences

  15. Distal splenorenal shunt with partial spleen resection

    Directory of Open Access Journals (Sweden)

    Gajin Predrag

    2007-01-01

    Full Text Available Introduction: Hypersplenism is a common complication of portal hypertension. Cytopenia in hypersplenism is predominantly caused by splenomegaly. Distal splenorenal shunt (Warren with partial spleen resection is an original surgical technique that regulates cytopenia by reduction of the enlarged spleen. Objective. The aim of our study was to present the advantages of distal splenorenal shunt (Warren with partial spleen resection comparing morbidity and mortality in a group of patients treated by distal splenorenal shunt with partial spleen resection with a group of patients treated only by a distal splenorenal shunt. Method. From 1995 to 2003, 41 patients with portal hypertension were surgically treated due to hypersplenism and oesophageal varices. The first group consisted of 20 patients (11 male, mean age 42.3 years who were treated by distal splenorenal shunt with partial spleen resection. The second group consisted of 21 patients (13 male, mean age 49.4 years that were treated by distal splenorenal shunt only. All patients underwent endoscopy and assessment of oesophageal varices. The size of the spleen was evaluated by ultrasound, CT or by scintigraphy. Angiography was performed in all patients. The platelet and white blood cell count and haemoglobin level were registered. Postoperatively, we noted blood transfusion, complications and total hospital stay. Follow-up period was 12 months, with first checkup after one month. Results In the first group, only one patient had splenomegaly postoperatively (5%, while in the second group there were 13 patients with splenomegaly (68%. Before surgery, the mean platelet count in the first group was 51.6±18.3x109/l, to 118.6±25.4x109/l postoperatively. The mean platelet count in the second group was 67.6±22.8x109/l, to 87.8±32.1x109/l postoperatively. Concerning postoperative splenomegaly, statistically significant difference was noted between the first and the second group (p<0.05. Comparing the

  16. Contemporary Management of Primary Distal Urethral Cancer.

    Science.gov (United States)

    Traboulsi, Samer L; Witjes, Johannes Alfred; Kassouf, Wassim

    2016-11-01

    Primary urethral cancer is one of the rare urologic tumors. Distal urethral tumors are usually less advanced at diagnosis compared with proximal tumors and have a good prognosis if treated appropriately. Low-stage distal tumors can be managed successfully with a surgical approach in men or radiation therapy in women. There are no clear-cut indications for the choice of the most appropriate treatment modality. Organ-preserving modalities have shown effective and should be used whenever they do not compromise the oncological safety to decrease the physical and psychological trauma of dismemberment or loss of sexual/urinary function. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Spontaneous distal rupture of the plantar fascia.

    Science.gov (United States)

    Gitto, Salvatore; Draghi, Ferdinando

    2018-07-01

    Spontaneous ruptures of the plantar fascia are uncommon injuries. They typically occur at its calcaneal insertion and usually represent a complication of plantar fasciitis and local treatment with steroid injections. In contrast, distal ruptures commonly result from traumatic injuries. We describe the case of a spontaneous distal rupture of the plantar fascia in a 48-year-old woman with a low level of physical activity and no history of direct injury to the foot, plantar fasciitis, or steroid injections. © 2017 Wiley Periodicals, Inc.

  18. Torsion of wandering spleen and distal pancreas

    International Nuclear Information System (INIS)

    Sheflin, J.R.; Lee, C.M.; Kretchmar, K.A.

    1984-01-01

    Wandering spleen is the term applied to the condition in which a long pedicle allows the spleen to lie in an abnormal location. Torsion of a wandering spleen is an unusual cause of an acute abdomen and is rarely diagnosed preoperatively. Associated torsion of the distal pancreas is even more uncommon. The authors describe a patient with torsion of a wandering spleen and distal pancreas, who was correctly diagnosed, and define the merits of the imaging methods used. The initial examination should be 99 /sup m/Tc-sulfur colloid liner-spleen scanning

  19. Outcomes of Distal Femur Fracture Treated with Dynamic Condylar Screw

    International Nuclear Information System (INIS)

    Razaq, M. N. U.; Muhammad, T.; Ahmed, A.; Adeel, M.; Ahmad, S.; Ahmad, S.; Sultan, S.

    2016-01-01

    Background: Implants for open reduction and internal fixation of distal femoral fracture includes angle blade plate, rush nails, enders nail and interlocking nails. But all these devices are technically demanding and less effective in providing inter-fragmentary compression in osteoporotic bones. These problems can be solved with dynamic condylar screw (DCS).The objective of the study was to determine the frequency of different outcomes of distal femoral fracture treated with dynamic condylar screw Methods: This case series study was carried out in the Department of Trauma and Orthopaedics, Ayub Teaching Hospital Abbottabad from 1st October 2014 to August 2015, after approval of the ethical committee of the institution. Data of all patients with distal femoral fractures aged 20-70 years, recruited through emergency, OPD or consultant clinic collected on a proforma. Standard treatment of trauma was given to the patients. Detailed history was taken including the past medical and surgical history. Detailed examination including air-way, breathing and circulation, general physical examination and abdomino-pelvic examination was done in each patient. Investigations including urinalysis, haemoglobin percent, full blood count, X-ray (both AP and lateral view) of the involved femur (including hip and knee) was done. Results: Mean age of the patients was 43.18±14.647 ranging from 20 to 70 years. Mean duration of hospital stay in days was 2.21±1.111 ranging from 1 to 6 days. Patients follow-up assessment after 4 months of surgery for union of femoral fracture treated with dynamic condylar screw was found in 96 (94.1 percent), wound infection was found in 7 (6.9 percent), knee stiffness was found in 21 (20.6 percent) and limb shortening was found in 7 (6.9 percent). Conclusion: Dynamic condylar screw is an easy, scientifically less difficult and satisfying method of treatment for fractures of femur. (author)

  20. Complicated distal femoral epiphyseolysis treated by Ilizarov method: Case report

    Directory of Open Access Journals (Sweden)

    Jovanović Vesna

    2010-01-01

    Full Text Available Introduction Injuries of the distal femur are rare in children; however, they are frequently associated with complications. They are almost always physeal, most frequently Salter-Harris type II epiphyseolysis. The treatment of such injuries is similar in all physeal injuries. It is intended to provide growth plate recovery by gentle reduction and stable fixation thus preventing secondary complications, and also to provide decompression of the segment to solve the compartment syndrome and recover the neurovascular structures. Case Outline A seven-year old boy presented with a right knee injury while sleigh riding. He was admitted three weeks following the injury with distal femoral epiphysiolysis associated with peroneal palsy. A day after admission to our Institute the reduction was performed using the Ilizarov device. Physical therapy was started immediately after surgery, as well as walking with weight bearing on the operated leg. Five months after surgery the patient was anatomically and functionally recovered. Conclusion The presented method is recommended in the treatment of such injuries because of several reasons; reposition is simple and complete, there is no need to open the fracture site, fixation is stable, the growth plate is preserved, there is no need for additional external immobilisation, and physical therapy involving walking with weight bearing on the operated leg may be started immediately after surgery. .

  1. Endovascular treatment of ruptured distal posterior inferior ...

    African Journals Online (AJOL)

    2014-03-01

    Mar 1, 2014 ... there are lots of reports regarding the interventional therapy of the artery aneurysms (including proximal and distal), all of which are considered to be safe and effective. All the incidences of interventional-related complications are below 10% and there is no report of injury of lower cranial nerves [11, 12].

  2. Urethral mobilization and advancement for distal hypospadias ...

    African Journals Online (AJOL)

    Background/purpose Despite the existence of numerous techniques for the repair of distal penile hypospadias, none of them is completely satisfactory. Advancing the urethra without mobilization for repair of glanular hypospadias has the advantage of avoiding a common problem occurring with other techniques: ...

  3. Safety and Effectiveness of the Nav-6 Filter in Preventing Distal Embolization During Jetstream Atherectomy of Infrainguinal Peripheral Artery Lesions.

    Science.gov (United States)

    Banerjee, Avantika; Sarode, Karan; Mohammad, Atif; Brilakis, Emmanouil S; Banerjee, Subhash; Shammas, Gail A; Shammas, Nicolas W

    2016-08-01

    The risk of distal embolization (DE) during infrainguinal peripheral artery interventions (PAI) is often mitigated by the use of embolic protection devices. There are limited data on the use of filters with the Jetstream (JS) atherectomy device, a rotational cutter with aspiration capacity. The Nav-6 filter is uniquely suited for use with the JS due to its wire compatibility and detachment from the filter; however, data on the off-label use of this combination have not been reported. Consecutive patients between October 2008 and April 2015 undergoing endovascular infrainguinal PAI with JS were analyzed as part of the Excellence in Peripheral Artery Disease (XL-PAD) registry (NCT01904851). Patients were divided into two subgroups with Nav-6 filter use vs no filter use. Descriptive and univariate analyses were performed. Among 141 patients (mean age, 67.8 ± 10.8 years; 169 lesions) included in this study, the Nav-6 filter was used in 82 (59%). Use of a filter was more frequent in longer lesions (146 ± 106 mm vs 91 ± 72 mm; P=.01), in more severe stenoses (95% vs 87%; P=.04), and in chronic total occlusions (33% vs 8.3%; P=.01). Patients receiving filters had longer procedure duration (102 ± 51 min vs 66 ± 41 min; P=.01) and longer fluoroscopy times (31 ± 16 min vs 21 ± 10 min; Patherectomy was predominantly used during complex infrainguinal PAI and was associated with less occurrence of DE.

  4. Minimally invasive locked plating of distal tibia fractures is safe and effective.

    Science.gov (United States)

    Ronga, Mario; Longo, Umile Giuseppe; Maffulli, Nicola

    2010-04-01

    Distal tibial fractures are difficult to manage. Limited soft tissue and poor vascularity impose limitations for traditional plating techniques that require large exposures. The nature of the limitations for traditional plating techniques is intrinsic to the large exposure required to approach distal tibia, a bone characterized by limited soft tissue coverage and poor vascularity. The locking plate (LP) is a new device for treatment of fractures. We assessed the bone union rate, deformity, leg-length discrepancy, ankle range of motion, return to preinjury activities, infection, and complication rate in 21 selected patients who underwent minimally invasive osteosynthesis of closed distal tibia fractures with an LP. According to the AO classification, there were 12 Type A, 5 Type B, and 4 Type C fractures. The minimum followup was 2 years (average, 2.8 years; range, 2-4 years). Two patients were lost to followup. Union was achieved in all but one patient by the 24th postoperative week. Four patients had angular deformity less than 7 degrees . No patient had a leg-length discrepancy more than 1.1 cm. Five patients had ankle range of motion less than 20 degrees compared with the contralateral side. Sixteen patients had not returned to their preinjury sporting or leisure activities. Three patients developed a delayed infection. We judge the LP a reasonable device for treating distal tibia fractures. The level of physical activities appears permanently reduced in most patients. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  5. Deep pain thresholds in the distal limbs of healthy human subjects.

    Science.gov (United States)

    Rolke, R; Andrews Campbell, K; Magerl, W; Treede, R-D

    2005-02-01

    Pressure pain thresholds (PPTs) in distal limbs have been under-investigated despite their potential clinical importance. Therefore, we compared PPTs over nail bed, bony prominences, and muscle in distal parts of upper and lower limbs. We investigated 12 healthy subjects using three handheld devices: a spring-loaded, analogue pressure threshold meter (PTM) with two operating ranges, and an electronic Algometer. PPTs were determined with three series of ascending stimulus intensities with a ramp of about 50 kPa/s. PPTs were normally distributed in logarithmic space. PPTs over different tissues varied significantly (ANOVA, pAlgometer than with PTMs (ANOVA, ptesting over muscle. There was no significant right-left difference (ANOVA, p=0.33). In spite of considerable variability across subjects, reproducibility within subjects was high (correlation coefficients>0.90). For within-subject comparisons, threshold elevations beyond 33-43% would be abnormal (95% confidence intervals), whereas only deviations from the group mean by at least a factor of two would be abnormal with respect to absolute normative values. PPTs over distal muscles were comparable to published values on proximal limb and trunk muscles. These findings suggest that pressure pain testing over distal muscles may be a sensitive test for deep pain sensitivity and that the simple and less expensive devices are sufficient for testing this tissue type. Intra-individual site-to-site comparisons will be more sensitive than absolute normative values.

  6. Palmar reconstruction of the triangular fibrocartilage complex for instability of the distal radioulnar joint: a biomechanical study.

    Science.gov (United States)

    Kataoka, T; Moritomo, H; Omokawa, S; Iida, A; Wada, T; Aoki, M

    2013-06-01

    We developed a new triangular fibrocartilage complex reconstruction technique for distal radioulnar joint instability in which the palmar portion of the triangular fibrocartilage complex was predominantly reconstructed, and evaluated whether such reconstruction can restore stability of the distal radioulnar joint in seven fresh cadaver upper extremities. Distal radioulnar joint instability was induced by cutting all soft-tissue stabilizers around the distal ulna. Using a palmar approach, a palmaris longus tendon graft was sutured to the remnant of the palmar radioulnar and ulnocarpal ligaments. The graft was then passed through a bone tunnel created at the fovea and was sutured. Loads were applied to the radius, and dorsopalmar displacements of the radius relative to the ulna were measured using an electromagnetic tracking device in neutral rotation, 60° supination and 60° pronation. We compared the dorsopalmar displacements before sectioning, before reconstruction and after reconstruction. Dorsopalmar instability produced by sectioning significantly improved in all forearm positions after reconstruction.

  7. Distal displacement of the maxilla and the upper first molar.

    Science.gov (United States)

    Baumrind, S; Molthen, R; West, E E; Miller, D M

    1979-06-01

    Data from a sample of 198 Class II cases treated with various appliances which deliver distally directed forces to the maxilla were examined to determine the frequency of absolute distal displacement of the upper first molar and of the maxilla. Analysis revealed that such distal displacement is possible and that it is, in fact, a frequent finding following treatment. Long-range stability of distal displacement was not assessed.

  8. Distal radioulnar joint: functional anatomy, including pathomechanics.

    Science.gov (United States)

    Haugstvedt, J R; Langer, M F; Berger, R A

    2017-05-01

    The distal radioulnar joint allows the human to rotate the forearm to place the hand in a desired position to perform different tasks, without interfering with the grasping function of the hand. The ulna is the stable part of the forearm around which the radius rotates; the stability of the distal radioulnar joint is provided by the interaction between ligaments, muscles and bones. The stabilizing structures are the triangular fibrocartilage complex, the ulnocarpal ligament complex, the extensor carpi ulnaris tendon and tendon sheath, the pronator quadratus, the interosseous membrane and ligament, the bone itself and the joint capsule. The purpose of this review article is to present and illustrate the current understanding of the functional anatomy and pathomechanics of this joint.

  9. Distal Stressors and Depression among Homeless Men

    OpenAIRE

    Coohey, Carol; Easton, Scott D.

    2016-01-01

    Depression is a common problem among homeless men that may interfere with functional tasks, such as securing stable housing, obtaining employment, and accessing health services. Previous research on depression among homeless men has largely focused on current psychosocial resources, substance abuse, and past victimization. Guided by Ensel and Lin’s life course stress process model, the authors examined whether distal stressors, including victimization and exposure to parent problems in childh...

  10. Fractures of the distal phalanx in the horse

    International Nuclear Information System (INIS)

    Yovich, J.V.

    1989-01-01

    Fractures of the distal phalanx are an important cause of lameness referable to the foot. Depending on the fracture configuration and articular involvement, conservative or surgical treatment may be required. Fractures of the distal phalanx have been divided into six categories based on fracture configuration. Discussion of clinical features, management, and prognosis for horses with distal phalangeal fractures is presented for each fracture type

  11. Nonunions of the distal tibia treated by reamed intramedullary nailing

    NARCIS (Netherlands)

    Richmond, Jeffrey; Colleran, Kevin; Borens, Olivier; Kloen, Peter; Helfet, David L.

    2004-01-01

    The purpose of this study is to determine the efficacy of reamed intramedullary nailing in the treatment of nonunions of the distal one-fourth of the tibia. Nonunions of the distal tibia are particularly difficult to treat given the short distal segment, the proximity to the ankle joint, and the

  12. Report by the work-group on 'safety of medical devices emitting ionizing radiations'. Articulation of radiation protection requirements of the 97/43/Euratom directive and IAEA recommendations with the essential requirements of the 93/42/CEE directive related to medical devices used in external radiotherapy

    International Nuclear Information System (INIS)

    2010-01-01

    As some dysfunctions and events had been reported in 2007 and 2008 in field of radiotherapy, this report aims at clarifying the articulation between the different European regulations concerning medical devices emitting ionizing radiations and radiation protection. The authors report a survey with device manufacturers, and analyze the content of the different regulations and recommendations. Then, the authors recommend and propose a set of actions related to the IAEA requirements and recommendations, to CE marking requirements, and to new radiation protection and safety requirements present in the Euratom directive

  13. Management and treatment of distal ulcerative colitis

    Directory of Open Access Journals (Sweden)

    Andrea Calafiore

    2013-12-01

    Full Text Available Ulcerative colitis (UC is a chronic inflammatory condition that is confined to the colonic mucosa. Its main symptoms include diarrhea, rectal bleeding and abdominal pain. Approximately two-thirds of UC patients have disease confined distal to the splenic flexure, which can be treated effectively with topical therapy. This means the active drug can be delivered directly to the site of inflammation, limiting the systemic absorption and potential side effects. Topical treatment with aminosalicylates is the most effective approach in the treatment of these forms, provided that the formulation reaches the upper margin of the disease. Given this, the suppository formulation is the treatment of choice for proctitis and distal sigmoiditis. Thanks to their proximal spread, enemas, foams and gels represent the treatment of choice for proctosigmoiditis and for distal ulcerative colitis. Oral aminosalicylates are less effective than topical therapies in patients with active disease, while the combination of topical and oral treatment is more effective in patients refractory to topical or oral mono-therapy. Topically administered aminosalicylates play an important role in the maintenance of remission, but the long-term adhesion to therapy is poor. For this reason, the oral formulation is the first-line therapy in the maintenance of remission. Refractory patients can be treated with topical steroids or systemic steroids and TNF-alpha inhibitors in severe forms.

  14. The Impact of Hearing Protection Devices (HPDs on Blood Pressure in Workers Exposed to Noise: A Cross-sectional Study in a Textile Industry

    Directory of Open Access Journals (Sweden)

    Jafar Akbari

    2018-06-01

    Full Text Available Many studies have reported that exposure to workplace noise leads to increase in blood pressure. The aim of this study was to investigate the effect of hearing protection devices (HPDs including ear plug and ear muff on the systolic and diastolic blood pressures of workers exposed to workplace noise in a textile industry. A total of 120 male workers that exposed to 95 dB noise were investigated in this study. The systolic and diastolic blood pressures of the workers were measured for three situations of earplug, earmuff and earplug along earmuff applications. Data analyses were conducted through SPSS software (version 20 and statistical tests of ANOVA and Independent Sample Tests. The comparison of mean blood pressure in three situations showed that using ear muff had a significant effect on the systolic and diastolic blood pressures in the workers. Furthermore, the use of ear plug only had an effect on the systolic blood pressure. But, the application of ear muff caused to decrease in the systolic and diastolic blood pressures only in the third stage of the study. With regard to the results in this study, in order to control the blood pressure changes of the workers, it is recommended to use ear muff in the textile industry.

  15. Development of a new model of actinic enteritis in rats using a cobalt-60 open source and a protection device as a collimator

    Energy Technology Data Exchange (ETDEWEB)

    Nunes, Vinicius Rodrigues Taranto; Vidigal, Paula Vieira Teixeira; Barbuto, Rafael Calvao; Duval-Araujo, Ivana, E-mail: vivas1912@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (UFMG), MG (Brazil); Pereira, Marcio Tadeu; Ladeira, Luis Carlos Duarte [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-03-15

    Purpose: To describe a new model of actinic enteritis that does not use radiotherapy machines. Methods: Sixteen Wistar rats were divided into four groups, consisting of four animals each: control (group A), two weeks after irradiation (group B), five weeks after irradiation (group C) and eight weeks after irradiation (group D). Animals were given a 10Gy radiation from a Cobalt-60 natural source in a nuclear technology research center. Protections of the surrounding tissues were obtained through the usage of plumb devices with a hole in the center, which served as a collimator. We obtained irradiated and non-irradiated colons from each animal. Results: In group B we found an important inflammatory response in the irradiated colon, which appeared in a reduced way in group C and was minimal in group D, in which we found a relevant collagen submucosal deposition/fibrosis. In all groups, the non-irradiated colon had a lower pathological damage in comparison with the irradiated colon. Conclusion: We thus described an efficient and feasible technique for obtaining an animal model of actinic enteritis. (author)

  16. Maxillary molar distalization with the dual-force distalizer supported by mini-implants: a clinical study.

    Science.gov (United States)

    Oberti, Giovanni; Villegas, Carlos; Ealo, Martha; Palacio, John Camilo; Baccetti, Tiziano

    2009-03-01

    The objective of this prospective study was to describe the clinical effects of a bone-supported molar distalizing appliance, the dual-force distalizer. The study group included 16 patients (mean age, 14.3 years) with Class II molar relationships. Study models and lateral cephalograms were taken before and after the distalizing movement to record significant dental and skeletal changes (Wilcoxon test). The average distalization time was 5 months, with a movement rate of 1.2 mm per month; the distalization amounts were 5.9 +/- 1.72 mm at the crown level and 4.4 +/- 1.41 mm at the furcation level. The average molar inclination was 5.6 degrees +/- 3.7 degrees ; this was less than the amount of inclination generated by bone-supported appliances that use single distalizing forces. The correlation between inclination and distalization was not significant, indicating predominantly bodily movement. The teeth anterior to the first molar moved distally also; the second premolars distalized an average of 4.26 mm, and the incisors retruded by 0.53 mm. The dual-force distalizer is a valid alternative distalizing appliance that generates controlled molar distalization with a good rate of movement and no loss of anchorage.

  17. Robotic distal pancreatectomy versus conventional laparoscopic distal pancreatectomy: a comparative study for short-term outcomes.

    Science.gov (United States)

    Lai, Eric C H; Tang, Chung Ngai

    2015-09-01

    Robotic system has been increasingly used in pancreatectomy. However, the effectiveness of this method remains uncertain. This study compared the surgical outcomes between robot-assisted laparoscopic distal pancreatectomy and conventional laparoscopic distal pancreatectomy. During a 15-year period, 35 patients underwent minimally invasive approach of distal pancreatectomy in our center. Seventeen of these patients had robot-assisted laparoscopic approach, and the remaining 18 had conventional laparoscopic approach. Their operative parameters and perioperative outcomes were analyzed retrospectively in a prospective database. The mean operating time in the robotic group (221.4 min) was significantly longer than that in the laparoscopic group (173.6 min) (P = 0.026). Both robotic and conventional laparoscopic groups presented no significant difference in spleen-preservation rate (52.9% vs. 38.9%) (P = 0.505), operative blood loss (100.3 ml vs. 268.3 ml) (P = 0.29), overall morbidity rate (47.1% vs. 38.9%) (P = 0.73), and post-operative hospital stay (11.4 days vs. 14.2 days) (P = 0.46). Both groups also showed no perioperative mortality. Similar outcomes were observed in robotic distal pancreatectomy and conventional laparoscopic approach. However, robotic approach tended to have the advantages of less blood loss and shorter hospital stay. Further studies are necessary to determine the clinical position of robotic distal pancreatectomy.

  18. An innovative technique to distalize maxillary molar using microimplant supported rapid molar distalizer

    Directory of Open Access Journals (Sweden)

    Meenu Goel

    2013-01-01

    Full Text Available Introduction: In recent years, enhancements in implants have made their use possible as a mode of absolute anchorage in orthodontic patients. In this paper, the authors have introduced an innovative technique to unilaterally distalize the upper left 1 st molar to obtain an ideal Class I molar relationship from a Class II existing molar relationship with an indigenous designed distalizer. Clinical Innovation: For effective unilateral diatalization of molar, a novel cantilever sliding jig assembly was utilized with coil spring supported by a buccally placed single micro implant. The results showed 3 mm of bodily distalization with 1 mm of intrusion and 2° of distal tipping of upper left 1 st molar in 1.5 months. Discussion: This appliance is relatively easy to insert, well-tolerated, and requires minimal patient cooperation compared to other present techniques of molar distalization. Moreover, it is particularly useful in cases that are Class II on one side and Class I on the other, with a minor midline discrepancy and nominal overjet. Patient acceptance level was reported to be within patients physiological and comfort limits.

  19. [New anterolateral approach of distal femur for treatment of distal femoral fractures].

    Science.gov (United States)

    Zhang, Bin; Dai, Min; Zou, Fan; Luo, Song; Li, Binhua; Qiu, Ping; Nie, Tao

    2013-11-01

    To assess the effectiveness of the new anterolateral approach of the distal femur for the treatment of distal femoral fractures. Between July 2007 and December 2009, 58 patients with distal femoral fractures were treated by new anterolateral approach of the distal femur in 28 patients (new approach group) and by conventional approach in 30 patients (conventional approach group). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, disease duration, complication, or preoperative intervention (P > 0.05). The operation time, intraoperative blood loss, intraoperative fluoroscopy frequency, hospitalization days, and Hospital for Special Surgery (HSS) score of knee were recorded. Operation was successfully completed in all patients of 2 groups, and healing of incision by first intention was obtained; no vascular and nerves injuries occurred. The operation time and intraoperative fluoroscopy frequency of new approach group were significantly less than those of conventional approach group (P 0.05). All patients were followed up 12-36 months (mean, 19.8 months). Bone union was shown on X-ray films; the fracture healing time was (12.62 +/- 2.34) weeks in the new approach group and was (13.78 +/- 1.94) weeks in the conventional approach group, showing no significant difference (t=2.78, P=0.10). The knee HSS score at last follow-up was 94.4 +/- 4.2 in the new approach group, and was 89.2 +/- 6.0 in the conventional approach group, showing significant difference between 2 groups (t=3.85, P=0.00). New anterolateral approach of the distal femur for distal femoral fractures has the advantages of exposure plenitude, minimal tissue trauma, and early function rehabilitation training so as to enhance the function recovery of knee joint.

  20. Miniscrew-assisted mandibular molar distalization in a patient with skeletal class-III malocclusion: A clinical case report

    Directory of Open Access Journals (Sweden)

    Seyed Mohammadreza Safavi

    2013-01-01

    Full Text Available In nongrowing patients with mild skeletal Class-III malocclusion, premolar extraction or molar distalization in the lower arch can be done as a part of camouflage treatment. Temporary anchorage devices are widely used for this purpose because they do not produce undesirable reciprocal effects and do not depend on the patient′s cooperation. However, most reported cases in this regard have used interradicular miniscrews in the mandibular arch and these have a risk of failure as they can loosen due to collision with adjacent roots. This article showcases mandibular molar distalization utilizing miniscrews, inserted at the retromolar area to correct a Class-III problem. A 24-year-old girl with a mild skeletal Class-III malocclusion and dental Class-III molar and canine relationship bilaterally was referred for orthodontic treatment. The treatment plan included distalization of the lower molars bilaterally followed by full fixed appliance therapy, after third molar extractions. For the lower molar distalization, the miniscrews were inserted at the retromolar pad. At the end of 21 months, a Class-I molar and canine relationship, normal overjet and overbite were obtained. The average amount of distalization of mandibular first molar was 3.2 mm at the crown level. In conclusion, placing miniscrews at the retromolar pad area for lower molar distalization was found to be a simple and effective method for correcting anterior cross bite and mandibular anterior crowding or protrusion, without the need for patient compliance.

  1. Periosteal osteoblastoma of the distal femur

    Energy Technology Data Exchange (ETDEWEB)

    Nakatani, Tetsuya; Yamamoto, Tetsuji; Akisue, Toshihiro; Marui, Takashi; Hitora, Toshiaki; Kawamoto, Teruya; Nagira, Keiko; Yoshiya, Shinichi; Kurosaka, Masahiro [Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe (Japan); Fujita, Ikuo; Matsumoto, Keiji [Department of Orthopaedic Surgery, Hyogo Medical Center for Adults, Akashi, Hyogo (Japan)

    2004-02-01

    Osteoblastomas located on the surface of the cortical bone, so-called periosteal osteoblastomas, are extremely rare. We report on a case of periosteal osteoblastoma arising from the posterior surface of the right distal femur in a 17-year-old man. Roentgenographic, computed tomographic, magnetic resonance imaging, and histologic features of the case are presented. Periosteal osteoblastoma should be radiologically and histologically differentiated from myositis ossificans, avulsive cortical irregularity syndrome, osteoid osteoma, parosteal osteosarcoma, periosteal osteosarcoma, and high-grade surface osteosarcoma. Although periosteal osteoblastoma is rare, this tumor should be included in the differential diagnosis of surface-type bone tumors. (orig.)

  2. Distal anastomotic vein adjunct usage in infrainguinal prosthetic bypasses.

    Science.gov (United States)

    McPhee, James T; Goodney, Philip P; Schanzer, Andres; Shaykevich, Shimon; Belkin, Michael; Menard, Matthew T

    2013-04-01

    ). The DVA group had a higher rate of completion angiogram performed (55.7% vs 37.5%; P =.002) and were more likely to be discharged on coumadin (53.4% vs 37.1%; P =.01). By multivariable analysis, use of a distal DVA was protective against MALEs (hazard ratio, 0.36; 95% confidence interval, 0.14-0.90; P = .03). This contemporary multi-institutional propensity-matched study demonstrates that patients that receive distal anastomotic vein adjuncts as part of infrainguinal prosthetic bypass operations in general have more extreme comorbidities and more technically challenging operations based on level of target vessel and prior bypass attempts. After propensity-matched analysis, the use of a DVA may protect against MALEs in prosthetic bypass surgery and should be considered when feasible. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  3. Main radiation protection actions for medical personnel as primary responders front of an event with radiological dispersive device; Principais acoes de protecao radiologica para equipe medica como primeiros respondedores frente a um evento com dispositivo de dispersao radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Duque, Hildanielle Ramos

    2015-07-01

    After the terrorist attack in New York, USA, in 2001, there was a worldwide concern about possible attacks using radioactive material in conventional detonators, called as Radiological Dispersal Device (RDD) or 'dirty bomb'. Several studies have been and are being made to form a global knowledge about this type of event. As until now, fortunately, there has not been an event with RDD, the Goiania Radiological Accident in Brazil, 1987, is used as a reference for decision-making. Several teams with technical experts should act in an event with RDD, but the medical staffs who respond quickly to the event must be properly protected from the harmful effects of radiation. Based on the radiological protection experts performance during the Goiania accident and the knowledge from lessons learned of many radiological accidents worldwide, this work presents an adaptation of the radiation protection actions for an event with RDD that helps a medical team as primary responders. The following aspects are presented: the problem of radioactive contamination from the explosion of the device in underground environment, the actions of the first responders and evaluation of health radiation effects. This work was based on specialized articles and papers about radiological accidents and RDD; as well as personal communication and academic information of the Institute of Radiation Protection and Dosimetry. The radiation protection actions, adapted to a terrorist attack event with RDD, have as a scenario a subway station in the capital. The main results are: the use of the basic radiation protection principle of time because there is no condition to take care of a patient keeping distance or using a shielding; the use of full appropriate protection cloths for contaminating materials ensuring the physical safety of professionals, and the medical team monitoring at the end of a medical procedure, checking for surface contamination. The main conclusion is that all medical actions

  4. Radiographic anatomy of the distal dural SAC

    International Nuclear Information System (INIS)

    Larsen, J.L.; Olsen, K.O.

    1991-01-01

    A radio-anatomical study was performed of the distal dural sac (DS) in 121 patients subjected to myelography. In 83.4% the termination of the DS was located from the upper half of the S1-segment to the lower half of the S2-segment. In the remaining patients the dural terminations were more distally located. The average location of the DS-termination was higher than that found in a previous anatomic study. The inference is that in patients with low-back pain and sciatica, the DS tends to terminate at a higher spinal level than in a non-selected anatomic material. The caudal reduction in sagittal diameter of the DS was less than that of the frontal diameter of the sac. The linear diminution in cross-sectional area of the DS from the level of L3 towards the lumbosacral junction was not correlated with the degree of caudal extension of the DS into the sacrum. Thus the length of the DS and its transverse diameters are independent of each other. These results supported the view that the location of the termination of the DS (and hence that of the spinal cord) is not related to stenosis of the central spinal canal. (orig.)

  5. Maxillary molar distalization with first class appliance.

    Science.gov (United States)

    Ramesh, Namitha; Palukunnu, Biswas; Ravindran, Nidhi; Nair, Preeti P

    2014-02-27

    Non-extraction treatment has gained popularity for corrections of mild-to-moderate class II malocclusion over the past few decades. The distalization of maxillary molars is of significant value for treatment of cases with minimal arch discrepancy and mild class II molar relation associated with a normal mandibular arch and acceptable profile. This paper describes our experience with a 16-year-old female patient who reported with irregularly placed upper front teeth and unpleasant smile. The patient was diagnosed to have angles class II malocclusion with moderate maxillary anterior crowding, deep bite of 4 mm on a skeletal class II base with an orthognathic maxilla and retrognathic mandible and normal growth pattern. She presented an ideal profile and so molar distalization was planned with the first-class appliance. Molars were distalised by 8 mm on the right and left quadrants and class I molar relation achieved within 4 months. The space gained was utilised effectively to align the arch and establish a class I molar and canine relation.

  6. Dermal pocketing following distal finger replantation.

    Science.gov (United States)

    Puhaindran, Mark E; Paavilainen, Pasi; Tan, David M K; Peng, Yeong Pin; Lim, Aymeric Y T

    2010-08-01

    Replantation is an ideal technique for reconstruction following fingertip amputation as it provides 'like for like' total reconstruction of the nail complex, bone pulp tissue and skin with no donor-site morbidity. However, fingertips are often not replanted because veins cannot be found or are thought to be too small to repair. Attempts at 'cap-plasty' or pocketing of replanted tips with and without microvascular anastomosis have been done in the past with varying degrees of success. We prospectively followed up a group of patients who underwent digital replantation and dermal pocketing in the palm to evaluate the outcome of this procedure. There were 10 patients with 14 amputated digits (two thumbs, five index, four middle, two ring and one little) who underwent dermal pocketing of the amputated digit following replantation. Among the 14 digits that were treated with dermal pocketing, 11 survived completely, one had partial atrophy and two were completely lost. Complications encountered included finger stiffness (two patients) and infection of the replanted fingertip with osteomyelitis of the distal phalanx (one patient). We believe that this technique can help increase the chance of survival for distal replantation with an acceptable salvage rate of 85% in our series. Copyright 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Osteoid osteoma of the distal clavicle

    Directory of Open Access Journals (Sweden)

    Bernardo Barcellos Terra

    Full Text Available ABSTRACT The osteoid osteoma is a bone tumor that accounts for 10% of benign tumors. It was described in 1935 by Jaffe, as a tumor that affects the young adult population, with a predominance of males. This study aims to present a case of late diagnosis of a patient with osteoid osteoma of the distal clavicle region. Female patient, 44 years old, non-professional volleyball player, reported pain in the anterior and superior region of the shoulder girdle, specifically in the acromioclavicular joint, which worsened at night and had been treated for nine months as tendinitis of the rotator cuff and acromioclavicular joint arthritis. After confirming the diagnosis, the patient underwent open surgery with resection of the distal clavicle. At two years of follow-up, the patient presents without local pain. In the radiographic evaluation, coracoclavicular distance is preserved and there are no signs of recurrence. Tumors of the shoulder girdle are rare and are often diagnosed late. A high degree of suspicion for the diagnosis of tumors of the shoulder girdle is needed in order to avoid late diagnosis.

  8. Biotin absorption by distal rat intestine

    International Nuclear Information System (INIS)

    Bowman, B.B.; Rosenberg, I.H.

    1987-01-01

    We used the in vivo intestinal loop approach, with short (10-min) and long (3-h) incubations, to examine biotin absorption in proximal jejunum, distal ileum, cecum and proximal colon. In short-term studies, luminal biotin disappearance from rat ileum was about half that observed in the jejunum, whereas absorption by proximal colon was about 12% of that in the jejunum. In 3-h closed-loop studies, the absorption of 1.0 microM biotin varied regionally. Biotin absorption was nearly complete in the small intestine after 3 h; however, only about 15% of the dose had been absorbed in the cecum and 27% in the proximal colon after 3 h. Independent of site of administration, the major fraction of absorbed biotin was recovered in the liver; measurable amounts of radioactive biotin were also present in kidney and plasma. The results support the potential nutritional significance for the rat of biotin synthesized by bacteria in the distal intestine, by demonstrating directly an absorptive capability of mammalian large bowel for this vitamin

  9. [Distal ureteral lithiasis. ESWL versus ambulatory URS].

    Science.gov (United States)

    Miján Ortiz, J L; Gutiérrez Tejero, F; López Carmona, F; Nogueras Ocaña, M; Arrabal Martín, M; Zuluaga Gómez, A

    2001-11-01

    To present the results achieved in the treatment of 1802 distal ureteral stones treated at the Lithotripsy Unit of the San Cecilio University Hospital over the last 10 years (1990-2000). Stones were treated by extracorporeal shock wave lithotripsy (ESWL) or ureteroscopy (URS). ESWL was the initial treatment in 81% of the cases (1460 calculi) and URS in the remaining 19% (342 stones). URS was performed for complication or failed ESWL (102 stones) and ESWL was performed for failed URS, basically due to stone migration (24 stones). Ureterolithotomy was required on 7 occasions. Sedation-analgesia with fentanyl and midazolam was routinely used in URS. Sedation was required in only 55% of the ESWL procedures. Elective ESWL resolved 93% of the cases, a percentage which is similar to that achieved with URS as first treatment. The ESWL retreatment rate was 1.3. URS was successful in 98% of the cases of failed ESWL. There are two treatment modalities for stones in the distal ureter: ESWL and URS. We advocate the use of outpatient URS with sedation preferably in the female patient, impacted stones, obstructive uropathy, stones larger than 2 cm and radiotransparent stones.

  10. A STUDY OF SURGICAL MANAGEMENT OF DISTAL FEMORAL FRACTURES BY DISTAL FEMORAL LOCKING COMPRESSION PLATE OSTEOSYNTHESIS

    Directory of Open Access Journals (Sweden)

    Dema Rajaiah

    2016-08-01

    Full Text Available AIMS AND OBJECTIVES To study the fractures of distal end of femur and the mechanism of injury in distal end femur fractures, the advantages and disadvantages of open reduction and internal fixation of distal end femur fractures by distal femoral locking compression plate osteosynthesis and to analyse the outcome in terms of range of Knee motion, time to union, and limb shortening. RESULTS The mean age of patient is 44 years, 85% are males, road traffic accidents account for majority (80%, right side involved in 70%, Muller’s type C fracture is common, good range of movements is seen 90% of cases and union occurred in 95% in 5 months. The results were assessed using Neer’s score, seven (35% patients had excellent results, eight (40% patients had good results, four (20% patients had fair results and one (5% patient had poor result. CONCLUSION From our study, we conclude that DF-LCP is a safe and reliable implant and has shown excellent to satisfactory results in majority of intra-articular fractures (AO type C. Fixation with locking compression plate showed more effectiveness in severely osteoporotic bones, shorter operative stay, faster recovery, faster union rates and excellent functional outcome.

  11. Is there any evidence that cerebral protection is beneficial? Experimental data.

    Science.gov (United States)

    Macdonald, S

    2006-04-01

    This article presents the available experimental data from the world literature on the use of cerebral protection devices during carotid artery stenting (CAS). Clinical studies relying on surrogate markers of cerebral embolisation in place of neurological event rate as primary outcome measures are evaluated alongside bench-top and animal studies. These surrogate markers include evaluations of outcomes using procedural transcranial Doppler (TCD) and diffusion-weighted magnetic resonance imaging of brain (DWI). Pathological analyses of debris retrieved from in-vivo analyses of protection devices are also included in this review because although the focus of these studies was primarily clinical, the laboratory data will be preferentially presented and it provides interesting insights. It can be shown that each of the three philosophies of cerebral protection, namely flow arrest (proximal or distal), flow reversal and distal filtration is capable of the entrapment of sizeable debris that would logically threaten devastating stroke if it embolized to the brain. Whilst balloon occlusion significantly reduces the procedural microembolic load (particles less than 60 mm) and flow reversal may be the first means to entirely eliminate it, filters may be associated with increased microembolization. This has been described by some workers as controlled embolization. Certainly, particles smaller than the pore size of currently available filters (60-140 mm) will readily evade capture due to filter periflow and through-flow. There is evidence to suggest that tens of thousands of particles of this size may be released during CAS and there is some evidence that this may be associated with more new white lesions on DWI of brain. The clinical consequences of this controlled embolization however, remain unclear and sophisticated neuropsychometric test batteries may need to be applied at later time points to detect subtle injury that may be compounded by a late inflammatory response

  12. The anatomy and physiology of the suspensory apparatus of the distal phalanx.

    Science.gov (United States)

    Pollitt, Christopher C

    2010-04-01

    The equine hoof capsule protects the softer, more sensitive, structures within. Failure of the connection between hoof and bone (suspensory apparatus of the distal phalanx or SADP) results in the crippling lameness of laminitis. Active basal cell proliferation occurs principally in tubular hoof and proximal and distal lamellae. The remaining lamellae are virtually non-proliferative and the hoof wall moves past the stationary distal phalanx, by controlled activation and inhibition of constituent proteases. The lamellar corium derives most of its blood supply from the branches of the terminal arch which perforate the distal phalanx. Valveless veins within the foot can be exploited clinically for retrograde venous therapy or contrast radiography (venography). The basement membrane (BM) forms the interface between the lamellar epidermis and the adjacent dermis and the plasma membrane of each lamellar basal cell is attached to the BM by numerous electron dense adhesion plaques or hemidesmosomes the ultimate attachment unit of the SADP. Laminitis destroys and dislocates the BM and its components and without an intact, functional BM, the structure and function of the lamellar epidermis is pathologically compromised. Transcription and activation of constituent proteases occurs in normal hoof lamellae but in increased amounts during laminitis. Copyright 2010 Elsevier Inc. All rights reserved.

  13. Distal Communication by Chimpanzees (Pan troglodytes): Evidence for Common Ground?

    Science.gov (United States)

    Leavens, David A; Reamer, Lisa A; Mareno, Mary Catherine; Russell, Jamie L; Wilson, Daniel; Schapiro, Steven J; Hopkins, William D

    2015-01-01

    van der Goot et al. (2014) proposed that distal, deictic communication indexed the appreciation of the psychological state of a common ground between a signaler and a receiver. In their study, great apes did not signal distally, which they construed as evidence for the human uniqueness of a sense of common ground. This study exposed 166 chimpanzees to food and an experimenter, at an angular displacement, to ask, "Do chimpanzees display distal communication?" Apes were categorized as (a) proximal or (b) distal signalers on each of four trials. The number of chimpanzees who communicated proximally did not statistically differ from the number who signaled distally. Therefore, contrary to the claim by van der Goot et al., apes do communicate distally. © 2015 The Authors. Child Development © 2015 Society for Research in Child Development, Inc.

  14. Outflow protection filters during percutaneous recanalization of lower extremities' arterial occlusions: a pilot study

    International Nuclear Information System (INIS)

    Siablis, Dimitrios; Karnabatidis, Dimitrios; Katsanos, Konstantinos; Ravazoula, Panagiota; Kraniotis, Pantelis; Kagadis, George C.

    2005-01-01

    Purpose: Filter devices are already employed for the protection of carotid, coronary and renal distal vascular bed during endovascular procedures. This is a pilot study investigating their feasibility, safety and distal emboli protection capability during recanalization of lower extremities' acute and subacute occlusions. Materials and methods: Study population included 16 patients, 11 with a subacute arterial occlusion and 5 with an acute episode. The Trap filter (Microvena, USA) and its successor the Spider filter (EV3, USA) were utilized. Subacute occlusions were dealt with standard angioplasty and stenting procedures, while acute ones were managed primarily with Angiojet rheolytic thrombectomy. Outflow arterial tree was checked angiographically in-between consequent procedural steps. Embolic material collected after filter recovery was analyzed histopathologically. Patients' follow-up was scheduled at 1 month. Results: Seventeen filter baskets were applied in the recanalization of 16 target lesions in total. Mean length of the occluded segments was 6.1 (range: 2-15 cm; S.D. = 3.7 cm). Mean in situ time of the filters was 38.75 min (range: 20-60 min; S.D. 12.71 min). Technical success rate of deployment and utilization of the filtration devices was 100% (17/17). Procedural success rate of the recanalization was 100% (16/16) without any clinical or angiographic evidence of periprocedural distal embolization. Macroscopic particulate debris was extracted from all the filters (17/17) containing fresh thrombus, calcification minerals, cholesterol and fibrin. Mean diameter of the largest particle per specimen was 1702.80 (range: 373.20-4680.00 μm; S.D. 1155.12 μm). No adverse clinical events occurred at 1-month follow-up with 100% limb salvage (16/16). Conclusion: The application of outflow protection filters is safe, feasible and efficacious in hindering distal embolization complications and safeguarding the distal capillary bed. Nevertheless, this is a pilot study

  15. Study on the influence of package parasitics and substrate resistance on the Charged Device Model(CDM) failure levels - possible protection methodology

    NARCIS (Netherlands)

    Sowariraj, M.S.B.; Smedes, Theo; Salm, Cora; Mouthaan, A.J.; Kuper, F.G.

    2003-01-01

    Charged Device Model (CDM) type of Electrostatic Discharge (ESD) stress events are becoming the major reason for field returns in the Integrated Circuit (IC) industry especially with downscaling of device dimensions and increased usage of automated handlers. In the case of CDM stress, the IC is both

  16. Distal renal tubular acidosis and hepatic lipidosis in a cat.

    Science.gov (United States)

    Brown, S A; Spyridakis, L K; Crowell, W A

    1986-11-15

    Clinical and laboratory evidence of hepatic failure was found in a chronically anorectic cat. Simultaneous blood and urine pH determinations established a diagnosis of distal renal tubular acidosis. The cat did not respond to treatment. Necropsy revealed distal tubular nephrosis and hepatic lipidosis. The finding of distal renal tubular acidosis in a cat with hepatic lipidosis emphasizes the importance of complete evaluation of acid-base disorders in patients.

  17. MODELING PROTECTIVE DEVICES FOR DISTRIBUTION SYSTEMS WITH DISTRIBUTED GENERATION USING AN EMTP-TYPE TOOL REPRESENTACIÓN EN EMTP DE DISPOSITIVOS DE PROTECCIÓN DE REDES DE DISTRIBUCIÓN CON GENERACIÓN DISTRIBUIDA

    Directory of Open Access Journals (Sweden)

    Juan A Martínez-Velasco

    2010-08-01

    Full Text Available This paper presents the main features of a library of modules for representation of protective devices of distribution networks with distributed generation (DG. The impact of distributed generation in a distribution network depends, among other aspects, on the design of the protection system and the coordination between the different protective devices. The presence of distributed generation changes the radial nature of distribution systems and affects the performance of the protection system. This document discusses the present protection practices for distribution systems and DG interties, describes the implementation of protective devices (circuit breakers, relays, reclosers, fuses, sectionalizers in an EMTP-type tool, and presents some simulation results whose main goal is to analyze the impact of synchronous machine-based embedded generators on the coordination between the different types of protective devices.Este artículo presenta las características principales de una librería de módulos desarrollada para representar dispositivos de protección de una red de distribución de energía eléctrica con generación distribuida (GD. El impacto de la generación distribuida depende, entre otros aspectos, del diseño del sistema de protección, y de la coordinación entre los diferentes dispositivos de protección. La presencia de unidades generadoras altera el flujo radial inherente a un sistema de distribución y afecta al comportamiento del sistema de protección. Este trabajo presenta una introducción de los sistemas de protección de las redes de distribución y de la interconexión de unidades generadoras, describe la implantación de dispositivos de protección (interruptores, relés, reenganchadores, fusibles, seccionalizadores en un programa tipo EMTP, y presenta algunos resultados obtenidos mediante simulación, cuyo principal objetivo es ilustrar el impacto que la generación distribuida basada en generadores síncronos puede

  18. Post-transplant distal limb syndrome

    Directory of Open Access Journals (Sweden)

    María Florencia Borghi Torzillo

    2017-02-01

    Full Text Available The post-transplant distal limb syndrome is a not well known entity, with a prevalence of 5% in patients with renal transplant. Its diagnosis is based on clinical symptoms, bone scintigraphy and MRI, it has a benign course and the patient recovers without sequel. We present the case of a 37-year-old male, with medical history of hypertension, Berger's disease in 1999 that required dialysis three times a week for four years (2009-2013 and renal transplant in 2013. The patient consults on January 2014 referring severe pain in both feet, with sudden onset; he remembers the exact date of the beginning of the pain and denies trauma, pain prevents ambulation. The bone scintigraphy shows pathological uptake in both feet with no difference between the two. Although there is no treatment for this disease, it has a benign course

  19. Development of a colonoscopy add-on device for improvement of the intubation process

    Directory of Open Access Journals (Sweden)

    Litten JD

    2011-12-01

    Full Text Available Jonathan D Litten1, JungHun Choi2, David Drozek31Department of Mechanical Engineering; 2Department of Mechanical Engineering and Biomedical Engineering Program; 3College of Osteopathic Medicine, Department of Specialty Medicine, Ohio University, Athens, OH, USAAbstract: A colonoscopy add-on device has been developed to reduce intubation time without modification of the current colonoscope and peripheral devices. One of the main purposes of the system is to minimize trauma caused by the distal tip of the colonoscope. The detachable sensory fixture at the end of the distal tip measures the distance between the distal tip and the colon wall in three directions, and the actuation system attached at the base of the colonoscope controls the distal tip by rotating two dial knobs. The device controls the distal tip to minimize contact between the distal tip and the colon wall, and the distal tip ideally points out the next possible lumen. A compatibility test of the infrared sensory system was carried out, and the design of the actuation system was accomplished. The system is integrated and controlled by a microprocessor. The device was tested in a silicon colon and porcine intestine. The results showed that a colonoscopist successfully reached the cecum with the aid of the colonoscopy add-on device without significant contact between the colon wall and the distal tip. The colonoscopy aid device was very helpful for the novice colonoscopist.Keywords: colonoscope, infrared sensors, intubation, trauma, colonoscopy training model

  20. Comparison of standard laparoscopic distal pancreatectomy with minimally invasive distal pancreatectomy using the da Vinci S system.

    Science.gov (United States)

    Ito, Masahiro; Asano, Yukio; Shimizu, Tomohiro; Uyama, Ichiro; Horiguchi, Akihiko

    2014-01-01

    Minimally invasive procedures for pancreatic pathologies are increasingly being used, including distal pancreatectomy. This study aimed to assess the indications for and outcomes of the da Vinci distal pancreatectomy procedure. We reviewed the medical records of patients who underwent pancreatic head resection from April 2009 to September 2013. Four patients (mean age, 52.7 years) underwent da Vinci distal pancreatectomy and 10 (mean age, 68.0 +/- 12.1 years) underwent laparoscopic distal pancreatectomy. The mean surgical duration was 292 +/- 153 min and 306 +/- 29 min, the mean blood loss was 153 +/- 71 mL and 61.7 +/- 72 mL, and the mean postoperative length of stay was 24 +/- 11 days and 14 +/- 3 days in the da Vinci distal pancreatectomy and laparoscopic distal pancreatectomy groups, respectively. One patient who underwent da Vinci distal pancreatectomy developed a pancreatic fistula, while 2 patients in the laparoscopic distal pancreatectomy group developed splenic ischemia and gastric torsion, respectively. Laparoscopic and robotic pancreatic resection were both safe and feasible in selected patients with distal pancreatic pathologies. Further studies are necessary to clarify the role of robotic surgery in the advanced laparoscopic era.

  1. [Comparison of laparoscopic distal pancreatectomy and open distal pancreatectomy in pancreatic ductal adenocarcinoma].

    Science.gov (United States)

    Xu, K; Su, J J; Su, M; Yan, L; Feng, J; Xin, X L; Chen, Y L

    2017-10-23

    Objective: To compare and evaluate the curative effect of laparoscopic distal pancreatectomy(LDP) and traditional open distal pancreatectomy(ODP) in pancreatic ductal adenocarcinoma. Methods: The clinical data of 15 patients treated by LDP and 87 contemporaneous cases treated by ODP from January 2010 to November 2015 was collected, and the curative effect and prognosis of these patients were retrospectively analyzed. Results: The operation time of LDP group was (286.5±48.1) min, significantly longer than that of OPD group(226.6±56.8) min ( P 0.05). In both LDP group and ODP group, none occurred percutaneous drainage, re-admissions, second operation or perioperative death. Conclusions: Compared to ODP, LDP is much safer and more steady in perioperative periodand operation. Patients of pancreatic ductal adenocarcinoma received LDP can acquire more benefit and recovery sooner, and LDP is a safe and effective operative method.

  2. Early control of distal internal carotid artery during carotid endarterectomy: does it reduce cerebral microemboli?

    Science.gov (United States)

    Mommertz, G; Das, M; Langer, S; Koeppel, T A; Krings, T; Mess, W H; Schiefer, J; Jacobs, M J

    2010-06-01

    According to the results of the large trials on carotid endarterectomy (CEA), this type of surgery is only warranted if perioperative mortality and morbidity are kept considerably low. Less attention has been paid to methods of cerebral protection during CEA, although intraoperative transcranial Doppler (TCD) can visualise intracerebral microemboli (MES) during routine carotid dissection, although MES occur throughout the CEA, only those during dissection are related to neurological outcome. Prevention of MES by means of early control of the distal internal carotid artery dislodging from the carotid artery plaque during dissection is very likely the mechanism behind an eventual benefit from this approach. Hence, the amount of MES might serve as a surrogate parameter for the risk of periprocedural neurological events. So, the aim of the present study was to evaluate whether early control of the distal carotid artery during CEA is capable of reducing the number of MES by means of a prospective randomised trial. Twenty-eight patients (29 procedures) could be prospectively included in our study. Before surgery we randomly assigned the patients to two groups: group A (N.=12): CEA by means of early control of the distal internal carotid artery; group B (N.=17): CEA with dissection of the total carotid bifurcation before clamping the arteries. Periprocedurally, we continuously monitored the cerebral blood flow in the ipsilateral middle cerebral artery by means of TCD. Pre- and postoperative morbidity were independently verified by a neurologist control of the distal internal carotid artery did not reduce the occurrence of MES during dissection of the carotid bifurcation. Also, the total number of MES throughout the procedure and postoperatively was comparable between both groups. The procedure related times as well as the clinical outcome did not differ significantly. Thus, early control of the distal internal carotid artery has got no advantage but also no disadvantage

  3. Young Children's Sibling Relationship Quality: Distal and Proximal Correlates

    Science.gov (United States)

    Kretschmer, Tina; Pike, Alison

    2009-01-01

    Background: Relationships within families are interdependent and related to distal environmental factors. Low socioeconomic status (SES) and high household chaos (distal factors) have been linked to less positive marital and parent-child relationships, but have not yet been examined with regard to young children's sibling relationships. The…

  4. Distal clavicular osteolysis: MR evidence for subchondral fracture

    Energy Technology Data Exchange (ETDEWEB)

    Kassarjian, Ara; Palmer, William E. [Massachusetts General Hospital, Department of Radiology, Division of Musculoskeletal Radiology, Yawkey Center, Boston, MA (United States); Llopis, Eva [Hospital de la Ribera, Department of Radiology, Valencia (Spain)

    2007-01-15

    To investigate the association between distal clavicular osteolysis and subchondral fractures of the distal clavicle at MRI. This study was approved by the hospital human research committee, which waived the need for informed consent. Three radiologists retrospectively analyzed 36 shoulder MR examinations in 36 patients with imaging findings of distal clavicular osteolysis. The presence of a subchondral fracture of the distal clavicle, abnormalities of the acromioclavicular joint, rotator cuff tears and labral tears were assessed by MRI. These cases were then compared with 36 age-matched controls. At MRI, 31 of 36 patients (86%) had a subchondral line within the distal clavicular edema, consistent with a subchondral fracture. Of the 36 patients, 32 (89%) had fluid in the acromioclavicular joint, while 27 of 36 patients (75%) had cysts or erosions in the distal clavicle. There were 13 patients (36%) with associated labral tears, while eight patients (22%) had partial-thickness rotator cuff tears. In the control group one of 36 (3%) had a subchondral line (P<0.05), while ten of 36 (28%) had rotator cuff tears and 13 of 36 (36%) had labral tears. These latter two were not statistically significant between the groups. A distal clavicular subchondral fracture is a common finding in patients with imaging evidence of distal clavicular osteolysis. These subchondral fractures may be responsible for the propensity of findings occurring on the clavicular side of the acromioclavicular joint. (orig.)

  5. Distal clavicular osteolysis: MR evidence for subchondral fracture

    International Nuclear Information System (INIS)

    Kassarjian, Ara; Palmer, William E.; Llopis, Eva

    2007-01-01

    To investigate the association between distal clavicular osteolysis and subchondral fractures of the distal clavicle at MRI. This study was approved by the hospital human research committee, which waived the need for informed consent. Three radiologists retrospectively analyzed 36 shoulder MR examinations in 36 patients with imaging findings of distal clavicular osteolysis. The presence of a subchondral fracture of the distal clavicle, abnormalities of the acromioclavicular joint, rotator cuff tears and labral tears were assessed by MRI. These cases were then compared with 36 age-matched controls. At MRI, 31 of 36 patients (86%) had a subchondral line within the distal clavicular edema, consistent with a subchondral fracture. Of the 36 patients, 32 (89%) had fluid in the acromioclavicular joint, while 27 of 36 patients (75%) had cysts or erosions in the distal clavicle. There were 13 patients (36%) with associated labral tears, while eight patients (22%) had partial-thickness rotator cuff tears. In the control group one of 36 (3%) had a subchondral line (P<0.05), while ten of 36 (28%) had rotator cuff tears and 13 of 36 (36%) had labral tears. These latter two were not statistically significant between the groups. A distal clavicular subchondral fracture is a common finding in patients with imaging evidence of distal clavicular osteolysis. These subchondral fractures may be responsible for the propensity of findings occurring on the clavicular side of the acromioclavicular joint. (orig.)

  6. Intra-articular osteotomy for distal humerus malunion

    NARCIS (Netherlands)

    Marti, René K.; Doornberg, Job

    2009-01-01

    Intra-articular osteotomy is considered in the rare case of malunion after a fracture of the distal humerus to restore humeral alignment and gain a functional arc of elbow motion. Traumatic and iatrogenic disruption of the limited blood flow to the distal end of the humerus resulting in avascular

  7. Clinical relevance of distal biceps insertional and footprint anatomy

    NARCIS (Netherlands)

    van den Bekerom, Michel P J; Kodde, Izaäk F.; Aster, Asir; Bleys, Ronald L A W; Eygendaal, Denise

    2016-01-01

    Purpose: The aim of this review was to present an overview, based on a literature search, of surgical anatomy for distal biceps tendon repairs, based on the current literature. Methods: A narrative review was performed using Pubmed/Medline using key words: Search terms were distal biceps,

  8. Distal tibiofibular synostosis in a Nigerian: A case report | Owoeye ...

    African Journals Online (AJOL)

    X-ray of the bones showed an oblique fracture in the distal end of the shaft of fibula which is suggestive of post traumatic tibiofibular synostosis (TFS). Knowledge of distal TFS is important in resolving the puzzle of chronic shin pain of unknown origin and in accurate diagnosis of causes of ankle deformity and malformations.

  9. Radiographic study of distal radial physeal closure in thoroughbred horses

    International Nuclear Information System (INIS)

    Vulcano, L.C.; Mamprim, M.J.; Muniz, L.M.R.; Moreira, A.F.; Luna, S.P.L.

    1997-01-01

    Monthly radiography was performed to study distal radial physeal closure in ten male and ten female Throughbred horses. The height, thoracic circumference and metacarpus circumference were also measured, Distal radial physeal closure time was sooner in females than males, and took 701 +/- 37 and 748 +/- 55 days respectively

  10. A FUNCTIONAL EVALUATION STUDY OF DISTAL FEMORAL FRACTURES FIXED WITH DISTAL FEMORAL LOCKING PLATE

    Directory of Open Access Journals (Sweden)

    Manikumar C. J

    2017-04-01

    Full Text Available BACKGROUND Fractures of the distal femur present considerable challenges in management. Older patients especially women sustain fractures due to osteoporosis. Supracondylar fractures of femur have a bimodal distribution. They account for 6% of all femur fractures and 31% if hip fractures were excluded. Nearly, 50% of distal femur intra-articular fractures are open fractures. Before 1970, most supracondylar fractures were treated nonoperatively; however, difficulties were often encountered including persistent angulatory deformity, knee joint incongruity, loss of knee motion and delayed mobilisation. The trend of open reduction and internal fixation has become evident in recent years with good results being obtained with AO blade plate, dynamic condylar screw, intramedullary supracondylar nail and locking compression plate. Elderly patients and osteoporosis pose difficulty in treating intra-articular fractures of the lower end of femur. Loss of stable fixation is of great concern in these cases. Hence, locking compression plate use has an advantage in these patients. MATERIALS AND METHODS In this study, 20 patients with closed fracture of distal femur were studied. All the cases were treated at the Department of Orthopaedics, Rangaraya Medical College/Government General Hospital, Kakinada, Andhra Pradesh, between November 2013 and November 2015. The method used for fracture fixation was open reduction and internal fixation with distal femoral locking plate. The duration of follow up ranged from 3 months to 24 months. All the fractures in this series were posttraumatic. The patients were functionally evaluated with Neer’s scoring system. 1 RESULTS Twenty distal femoral fractures were treated with distal femoral locking plates. 15 patients were males and 5 patients were females. The median age was 47 years ranging from 28-70 years. 16 of the fractures were caused by road traffic accidents and 2 were due to fall, 2 were due to assault. 12 patients

  11. Rehabilitation for distal radial fractures in adults.

    Science.gov (United States)

    Handoll, Helen H G; Elliott, Joanne

    2015-09-25

    Fracture of the distal radius is a common clinical problem, particularly in older people with osteoporosis. There is considerable variation in the management, including rehabilitation, of these fractures. This is an update of a Cochrane review first published in 2002 and last updated in 2006. To examine the effects of rehabilitation interventions in adults with conservatively or surgically treated distal radial fractures. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL 2014; Issue 12), MEDLINE, EMBASE, CINAHL, AMED, PEDro, OTseeker and other databases, trial registers, conference proceedings and reference lists of articles. We did not apply any language restrictions. The date of the last search was 12 January 2015. Randomised controlled trials (RCTs) or quasi-RCTs evaluating rehabilitation as part of the management of fractures of the distal radius sustained by adults. Rehabilitation interventions such as active and passive mobilisation exercises, and training for activities of daily living, could be used on their own or in combination, and be applied in various ways by various clinicians. The review authors independently screened and selected trials, and reviewed eligible trials. We contacted study authors for additional information. We did not pool data. We included 26 trials, involving 1269 mainly female and older patients. With few exceptions, these studies did not include people with serious fracture or treatment-related complications, or older people with comorbidities and poor overall function that would have precluded trial participation or required more intensive treatment. Only four of the 23 comparisons covered by these 26 trials were evaluated by more than one trial. Participants of 15 trials were initially treated conservatively, involving plaster cast immobilisation. Initial treatment was surgery (external fixation or internal fixation) for all participants

  12. Distal Stressors and Depression among Homeless Men.

    Science.gov (United States)

    Coohey, Carol; Easton, Scott D

    2016-05-01

    Depression is a common problem among homeless men that may interfere with functional tasks, such as securing stable housing, obtaining employment, and accessing health services. Previous research on depression among homeless men has largely focused on current psychosocial resources, substance abuse, and past victimization. Guided by Ensel and Lin's life course stress process model, the authors examined whether distal stressors, including victimization and exposure to parent problems in childhood, contributed to men's depression above and beyond current (or proximal) stressors, such as substance abuse and health problems, and social resources. The sample consisted of 309 homeless men who had entered a federally funded emergency shelter. Using the Burns Depression Checklist, the authors found that one out of three men met the threshold for moderate to severe depression during the past week. The logistic regression showed that past exposure to parent problems was related to depression after accounting for current stressors and social resources (number of close adult relationships and whether their emotional support needs were met). Past victimization was not related to depression. To address men's depression, workers should concurrently provide services that meet men's basic needs (for example, housing) and address their relationship needs, including their need for emotional support.

  13. One-stage lengthening using a locked nailing technique for distal femoral shaft nonunions associated with shortening.

    Science.gov (United States)

    Wu, Chi-Chuan; Lee, Zhon-Liau

    2004-02-01

    To assess the effectiveness of a one-stage lengthening using a locked nail technique for the treatment of distal femoral shaft nonunions associated with shortening. Retrospective. University hospital. During a 6-year period, 36 distal femoral shaft nonunions associated with shortening (>1.5 cm) were treated by the one-stage lengthening technique. Indications for this technique were distal femoral shaft aseptic or quiescent infected nonunions, 1.5-5 cm shortening, and a fracture level suitable for the insertion of two distal locked screws. The surgical technique involved skeletal traction using the femoral condyle, local débridement, lengthening by lengthening was 2.5 cm (range 1.5-3.5 cm). One-stage lengthening using the locked nailing technique to treat distal femoral shaft nonunions associated with shortening can achieve a high success rate and low complication rate. The key to successful treatment is the patient's complete cooperation with strictly protected weight bearing until the fracture has healed.

  14. Linear intra-bone geometry dependencies of the radius: Radius length determination by maximum distal width

    International Nuclear Information System (INIS)

    Baumbach, S.F.; Krusche-Mandl, I.; Huf, W.; Mall, G.; Fialka, C.

    2012-01-01

    Purpose: The aim of the study was to investigate possible linear intra-bone geometry dependencies by determining the relation between the maximum radius length and maximum distal width in two independent populations and test for possible gender or age effects. A strong correlation can help develop more representative fracture models and osteosynthetic devices as well as aid gender and height estimation in anthropologic/forensic cases. Methods: First, maximum radius length and distal width of 100 consecutive patients, aged 20–70 years, were digitally measured on standard lower arm radiographs by two independent investigators. Second, the same measurements were performed ex vivo on a second cohort, 135 isolated, formalin fixed radii. Standard descriptive statistics as well as correlations were calculated and possible gender age influences tested for both populations separately. Results: The radiographic dataset resulted in a correlation of radius length and width of r = 0.753 (adj. R 2 = 0.563, p 2 = 0.592) and side no influence on the correlation. Radius length–width correlation for the isolated radii was r = 0.621 (adj. R 2 = 0.381, p 2 = 0.598). Conclusion: A relatively strong radius length–distal width correlation was found in two different populations, indicating that linear body proportions might not only apply to body height and axial length measurements of long bones but also to proportional dependency of bone shapes in general.

  15. Arthroscopic knotless anchor repair of triangular fibrocartilage in distal radius fracture.

    Science.gov (United States)

    García-Ruano, Á A; Najarro-Cid, F; Jiménez-Martín, A; Gómez de los Infantes-Troncoso, J G; Sicre-González, M

    2015-01-01

    Lesions of triangular fibrocartilage (TFC) are associated with distal radioulnar joint instability. Arthroscopic treatment of these lesions improves functional outcome of affected patients. The aim of the present work is to evaluate functional and occupational outcome of TCF repair using an arthroscopic knotless anchor device in patients with associated distal radius fracture. An observational, descriptive study was carried out between November 2011 and January 2014 including 21 patients with distal radius fracture and Palmer 1B lesions of TCF (Atzei class 2 and 3) that were treated by arthroscopic knotless anchor (PopLok® 2,8mm, ConMed, USA). Mean follow-up was 18 months. Functional (Mayo Wrist Score) and occupational outcome results were analyzed. Mean age of the group was 43.0±8.8 years, with 19% of the patients being female. There was an associated scapholunate lesion in 5 cases. Functional results reached a mean of 83.4±16.1 points onMayo Wrist Score. Mean sick-leave time was 153.16±48.5 days. Complete occupational reintegration was reached in 89.5% of cases. There were no postoperative complications. Arthroscopic knotless anchor repair of 1B TFC tears is a minimally invasive method of treatment that improves tension of fixation, avoiding subsequent loosen, in our experience, with few complications and good functional and occupational results. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  16. Protective effect of blue-light shield eyewear for adults against light pollution from self-luminous devices used at night.

    Science.gov (United States)

    Ayaki, Masahiko; Hattori, Atsuhiko; Maruyama, Yusuke; Nakano, Masaki; Yoshimura, Michitaka; Kitazawa, Momoko; Negishi, Kazuno; Tsubota, Kazuo

    2016-01-01

    We investigated sleep quality and melatonin in 12 adults who wore blue-light shield or control eyewear 2 hours before sleep while using a self-luminous portable device, and assessed visual quality for the two eyewear types. Overnight melatonin secretion was significantly higher after using the blue-light shield (P light shield (P light shield as providing acceptable visual quality.

  17. A comparison between robotic-assisted laparoscopic distal pancreatectomy versus laparoscopic distal pancreatectomy.

    Science.gov (United States)

    Goh, Brian K P; Chan, Chung Yip; Soh, Hui-Ling; Lee, Ser Yee; Cheow, Peng-Chung; Chow, Pierce K H; Ooi, London L P J; Chung, Alexander Y F

    2017-03-01

    This study aims to compare the early perioperative outcomes of robotic-assisted laparoscopic distal pancreatectomy (RDP) versus laparoscopic distal pancreatectomy (LDP). The clinicopathologic features of 45 consecutive patients who underwent minimally-invasive distal pancreatectomy from 2006 to 2015 were retrospectively reviewed. Thirty-nine patients who met our study criteria were included. Eight patients underwent RDP and 31 had LDP. There were 10 (25.6%) open conversions. Six (15.4%) patients had major (> grade 2) morbidities and there was no in-hospital mortality. There were 14 (35.9%) grade A and 9 (23.1%) grade B pancreatic fistulas. Comparison between RDP and LDP demonstrated no significant difference between the patients' baseline characteristics except there was increased frequency of spleen-preserving pancreatectomies (3 (37.5%) vs 25 (80.6%), P=0.016) and splenic-vessel preservation (5 (62.5%) vs 4 (12.9%), P=0.003) in RDP. Comparison between outcomes demonstrated that RDP was associated with a longer median operation time (452.5 (range, 300-685) vs 245 min (range, 85-430), P=0.001) and increased frequency of the procedure completed purely laparoscopically (8 (100%) vs 18 (58.1%), P=0.025). RDP can be safely adopted and is equivalent to LDP in most perioperative outcomes. It is also associated with a decreased frequency of the need for hand-assistance laparoscopic surgery or open conversion but needed a longer operation time. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Unilateral maxillary molar distalization with zygoma-gear appliance.

    Science.gov (United States)

    Kilkis, Dogan; Bayram, Mehmet; Celikoglu, Mevlut; Nur, Metin

    2012-08-01

    The aim of this study was to present the orthodontic treatment of a 15-year-old boy with a unilateral maxillary molar distalization system, called the zygoma-gear appliance. It consisted of a zygomatic anchorage miniplate, an inner bow, and a Sentalloy closed coil spring (GAC International, Bohemia, NY). A distalizing force of 350 g was used during the distalization period. The unilateral Class II malocclusion was corrected in 5 months with the zygoma-gear appliance. The maxillary left first molar showed distalization of 4 mm with an inclination of 3°. The maxillary premolars moved distally with the help of the transseptal fibers. In addition, there were slight decreases in overjet (-0.5 mm) and maxillary incisor inclination (-1°), indicating no anchorage loss from the zygoma-gear appliance. Preadjusted fixed appliances (0.022 × 0.028-in, MBT system; 3M Unitek, Monrovia, Calif) were placed in both arches to achieve leveling and alignment. After 14 months of unilateral distalization with the zygoma-gear appliance and fixed appliances, Class I molar and canine relationships were established with satisfactory interdigitation of the posterior teeth. Acceptable overjet and overbite were also achieved. This article shows that this new system, the zygoma-gear appliance, can be used for unilateral maxillary molar distalization without anchorage loss. Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  19. Potassium transport across guinea pig distal colon

    International Nuclear Information System (INIS)

    Rechkemmer, G.; Halm, D.R.; Frizzell, R.A.

    1986-01-01

    Active absorption and secretion of K was studied by measuring bidirectional 42 K fluxes across short-circuited guinea pig distal colon. Tissues were pretreated with mucosal (m) and serosal (s) indomethacin (1 μM) and amiloride (0.1 mM, m) to suppress spontaneous, electrogenic Cl secretion and Na absorption. Under these conditions, the short-circuit current (I/sub sc/) was 0.4 μeq/cm 2 h while electroneutral K absorption was 2.8 μeq/cm 2 h. Epinephrine (5 μM, s) stimulated electrogenic K secretion, reducing net K absorption to 1.3 μeq/cm 2 h. Bumetanide (0.1 mM, s) abolished this K secretion and restored K absorption to control values, suggesting mechanistic similarities between K and Cl secretion. K absorption was inhibited 40% by the gastric H/K ATPase inhibitor, omeprazole (0.1 mM, m), and was abolished by ouabain (0.1 mM, m). Neutral K absorption does not appear to be mediated by an apical membrane Na/K pump since: the effect of mucosal ouabain on K absorption does not require the presence of mucosal or serosal Na, unidirectional Na fluxes are not influenced by mucosal ouabain, and K absorption is not affected when Na absorption is abolished by amiloride. Net K transport is determined by the balance between electroneutral K absorption and electrogenic K secretion. The ouabain sensitivity of K absorption suggests that colonic H/K ATPase differs from its gastric counterpart

  20. Histology of the distal dural ring.

    Science.gov (United States)

    Graffeo, Christopher S; Perry, Avital; Copeland, William R; Raghunathan, Aditya; Link, Michael J

    2017-09-01

    The distal dural ring (DDR) is a conserved intracranial anatomic structure marking the boundary point at which the internal carotid artery (ICA) exits the cavernous sinus (CS) and enters the subarachnoid space. Although the CS has been well described in a range of anatomic studies, to our knowledge no prior study has analyzed the histologic relationship between the ICA and DDR. Correspondingly, our objective was to assess the relationship of the DDR to the ICA and determine whether the DDR can be dissected from the ICA and thus divided, or can only be circumferentially trimmed around the artery. The authors examined ten fresh-frozen, adult cadaveric specimens. A standard frontotemporal craniotomy, orbito-optic osteotomy, and extradural anterior clinoidectomy was performed bilaterally. The cavernous ICA, DDR, and supraclinoid ICA were harvested as an en bloc specimen. Specimens formalin-fixed and paraffin-embedded prior to routine histochemical staining with hematoxylin and eosin and Masson trichrome. In all specimens, marked microscopic investment of the DDR throughout the ICA adventitia was noted. Dural collagen fibers extensively permeated the arterial layers superficial to the muscularis propria, with no evidence of a clear separation between the DDR and arterial adventitia. Histologic analysis suggests that the ICA and DDR are highly interrelated, continuous structures, and therefore attempted intraoperative dissection between these structures may carry an elevated risk of injury to the ICA. We correspondingly recommend careful circumferential trimming of the DDR in lieu of direct dissection in cases requiring mobilization of the clinoidal ICA. Clin. Anat. 30:742-746, 2017. © 2017Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  1. Two-wave propagation in in vitro swine distal ulna

    Science.gov (United States)

    Mano, Isao; Horii, Kaoru; Matsukawa, Mami; Otani, Takahiko

    2015-07-01

    Ultrasonic transmitted waves were obtained in an in vitro swine distal ulna specimen, which mimics a human distal radius, that consists of interconnected cortical bone and cancellous bone. The transmitted waveforms appeared similar to the fast waves, slow waves, and overlapping fast and slow waves measured in the specimen after removing the surface cortical bone (only cancellous bone). In addition, the circumferential waves in the cortical bone and water did not affect the fast and slow waves. This suggests that the fast-and-slow-wave phenomenon can be observed in an in vivo human distal radius.

  2. Intra-Articular Osteotomy for Distal Humerus Malunion

    Directory of Open Access Journals (Sweden)

    René K. Marti

    2009-01-01

    Full Text Available Intra-articular osteotomy is considered in the rare case of malunion after a fracture of the distal humerus to restore humeral alignment and gain a functional arc of elbow motion. Traumatic and iatrogenic disruption of the limited blood flow to the distal end of the humerus resulting in avascular necrosis of capitellum or trochlea is a major pitfall of the this technically challenging procedure. Two cases are presented which illustrate the potential problems of intra-articular osteotomy for malunion of the distal humerus.

  3. Eye Protection

    OpenAIRE

    Pashby, Tom

    1986-01-01

    Eye injuries frequently occur in the home, at work and at play. Many result in legally blind eyes, and most are preventable. Awareness of potential hazards is essential to preventing eye injuries, particularly in children. In addition, protective devices must be used appropriately. We have developed eye protectors that have proved effective in reducing both the overall incidence and the severity of sports eye injuries.

  4. The distally-based island ulnar artery perforator flap for wrist defects

    Directory of Open Access Journals (Sweden)

    Karki Durga

    2007-01-01

    Full Text Available Background: Reconstruction of soft tissue defects around the wrist with exposed tendons, joints, nerves and bone represents a challenge to plastic surgeons, and such defects necessitate flap coverage to preserve hand functions and to protect its vital structures. We evaluated the use of a distally-based island ulnar artery perforator flap in patients with volar soft tissue defects around the wrist. Materials and Methods: Between June 2004 and June 2006, seven patients of soft tissue defects on the volar aspect of the wrist underwent distally-based island ulnar artery perforator flap. Out of seven patients, five were male and two patients were female. This flap was used in the reconstruction of the post road traffic accident defects in four patients and post electric burn defects in three patients. Flap was raised on one or two perforators and was rotated to 180°. Results: All flaps survived completely. Donor sites were closed primarily without donor site morbidity. Conclusion: The distally-based island Ulnar artery perforator flap is convenient, reliable, easy to manage and is a single-stage technique for reconstructing soft tissue defects of the volar aspect of the wrist. Early use of this flap allows preservation of vital structures, decreases morbidity and allows for early rehabilitation.

  5. Evaluation of the Scott Aviation Portable Protective Breathing Device for contaminant leakage as prescribed by FAA Action Notice A-8150.2.

    Science.gov (United States)

    1989-11-01

    Two types of crewmember protective breathing equipment (PBE) were performance tested for compliance with Action Notice A-8150.2 at ground level (- 1,300 feet) and 8,000 feet altitude. PBE 1 was a 'hood with oral-nasal mask,' which used potassium supe...

  6. Miniplate-Aided Mandibular Dentition Distalization as a Camouflage Treatment of a Class III Malocclusion in an Adult

    Directory of Open Access Journals (Sweden)

    Zaki Hakami

    2018-01-01

    Full Text Available This case report describes orthodontic camouflage treatment for a 32-year-old African American male patient with Class III malocclusion. The treatment included nonextraction, nonsurgical orthodontic camouflage by en masse distalization of the mandibular teeth using skeletal anchorage devices. The total treatment time was 23 months. Normal overjet and overbite with Class I occlusion were obtained despite the compensated dentition to the skeletal malocclusion. His smile esthetics was significantly improved at the completion of his treatment.

  7. Miniscrew-assisted mandibular molar distalization in a patient with skeletal class-III malocclusion: A clinical case report

    OpenAIRE

    Seyed Mohammadreza Safavi; Farnaz Younessian; Sarvraj Kohli

    2013-01-01

    In nongrowing patients with mild skeletal Class-III malocclusion, premolar extraction or molar distalization in the lower arch can be done as a part of camouflage treatment. Temporary anchorage devices are widely used for this purpose because they do not produce undesirable reciprocal effects and do not depend on the patient′s cooperation. However, most reported cases in this regard have used interradicular miniscrews in the mandibular arch and these have a risk of failure as they can loosen ...

  8. Miniplate-Aided Mandibular Dentition Distalization as a Camouflage Treatment of a Class III Malocclusion in an Adult.

    Science.gov (United States)

    Hakami, Zaki; Chen, Po Jung; Ahmida, Ahmad; Janakiraman, Nandakumar; Uribe, Flavio

    2018-01-01

    This case report describes orthodontic camouflage treatment for a 32-year-old African American male patient with Class III malocclusion. The treatment included nonextraction, nonsurgical orthodontic camouflage by en masse distalization of the mandibular teeth using skeletal anchorage devices. The total treatment time was 23 months. Normal overjet and overbite with Class I occlusion were obtained despite the compensated dentition to the skeletal malocclusion. His smile esthetics was significantly improved at the completion of his treatment.

  9. Combined open proximal and stent-graft distal repair for distal arch aneurysms: an alternative to total debranching.

    Science.gov (United States)

    Zierer, Andreas; Sanchez, Luis A; Moon, Marc R

    2009-07-01

    We present herein a novel, combined, simultaneous open proximal and stent-graft distal repair for complex distal aortic arch aneurysms involving the descending aorta. In the first surgical step, the transverse arch is opened during selective antegrade cerebral perfusion, and a Dacron graft (DuPont, Wilmington, DE) is positioned down the descending aorta in an elephant trunk-like fashion with its proximal free margin sutured circumferentially to the aorta just distal to the left subclavian or left common carotid artery. With the graft serving as the new proximal landing zone, subsequent endovascular repair is performed antegrade during rewarming through the ascending aorta.

  10. early functional outcome of distal femoral fractures at kenyatta

    African Journals Online (AJOL)

    The leading cause was RTA, followed by falls from a height. ... Distal femoral fractures cause considerable morbidity .... as means and standard deviations. .... Anaesthesia. Spinal. 37 (80). General Anaesthesia (GA). 9 (20). Transfusion.

  11. Subtrochanteric and Distal Femur Fractures in a Patient with ...

    African Journals Online (AJOL)

    This study reports the surgical management for this rare case and the treatment ... car accident and presented closed femoral shaft fracture associated with a ... to fix the distal femur fracture, enhancing the construction stability [Figures 4 and 5].

  12. Minimally invasive percutaneous plate fixation of distal tibia fractures.

    LENUS (Irish Health Repository)

    Bahari, Syah

    2007-10-01

    We report a series of 42 patients reviewed at a mean of 19.6 months after treatment of distal tibial and pilon fractures using the AO distal tibia locking plate with a minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. Mean time to union was 22.4 weeks. All fractures united with acceptable alignment and angulation. Two cases of superficial infection were noted, with one case of deep infection. Mean SF36 score was 85 and mean AOFAS score was 90 at a mean of 19 months follow-up. We report satisfactory outcomes with the use of the AO distal tibia locking plate in treatment of unstable distal tibial fractures. Eighty-nine percent of the patients felt that they were back to their pre injury status and 95% back to their previous employment.

  13. Surgical treatment of distal biceps tendon rupture: a case report

    Directory of Open Access Journals (Sweden)

    Cristina N. Cozma

    2017-11-01

    Full Text Available Objectives. Distal biceps tendon rupture affects the functional upperextremity movement, impairing supination and flexion strength. According to age, profession and additional risks treatment might be nonoperative or surgical. Methods. We describe the case of a 43 years old male patient who sustained an injury to his right distal biceps and was diagnosed with acute right distal biceps rupture. Surgical treatment was decided and biceps tendon was reinserted to the radius tuberosity using a combination of a cortical button fixation associated with an interference screw. Results. Postoperative functional result was favorable with no complications and with no movement limitation after one month. Conclusions. When possible, distal biceps tendon repair should be realized surgically because this permits restoring of the muscle strength to near normal levels with no loss of motion. Nerve complications are common; therefore the surgery should be realized by experienced upper extremity surgeons.

  14. Protection devices in the transmission grids, German practice. Typical protection concepts in Germany's power transmission lines; Schutzsysteme im Uebertragungsnetz, deutsche Praxis. Typische Schutzkonzepte im deutschen Uebertragungsnetz

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, Hans-Joachim [Siemens AG, Nuernberg (Germany). Sektor Energy, Energy Automation; Ludwig, Andrea [50 Hertz Transmission GmbH, Berlin (Germany). Schutztechnik, Anlagenmanagement; Kuehn, Holger [Tennet TSO GmbH, Bayreuth (Germany). Schutztechnik, Assetmanagement/Umspannwerke; Oechsle, Fred [EnBW Regional AG, Stuttgart (Germany). Netzschutz, Netzservice - Projekte Strom

    2011-04-18

    The contribution presents typical protection concepts for power grids. Solutions for power plant feed-in, bus bar, transmission lines and coupling transformer are explained. General information is provided on triggering concepts, on the design of d.c. power supply, selection of current inverters, and other subjects.

  15. Enclavado endomedular en fracturas del tercio distal de la tibia

    OpenAIRE

    Arroquy, Damian; Chahla, Jorge; Gomez Rodriguez, Gustavo; Cid Casteulani, Alberto; Svarzchtein, Santiago; Gomez, Diego; Pesciallo, Cesar

    2015-01-01

    Objetivo: Describir los resultados obtenidos con el enclavado endomedular acerrojado en pacientes con fractura del tercio distal de la tibia. Materiales y Métodos: Se incluyeron pacientes con fracturas desplazadas del tercio distal de la tibia, tratadas con clavo endomedular. La muestra incluyo 35 pacientes. El tiempo de seguimiento posoperatorio fue de 29.2 meses. Se evaluaron el tiempo de consolidacion, la consolidacion viciosa y las complicaciones. Los resultados funcionales se determinaro...

  16. Fractures of the Distal Tibia Treated with Polyaxial Locking Plating

    OpenAIRE

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2008-01-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial in...

  17. The role of imaging in diagnosing diseases of the distal radioulnar joint, triangular fibrocartilage complex, and distal ulna.

    Science.gov (United States)

    Squires, Judy H; England, Eric; Mehta, Kaushal; Wissman, Robert D

    2014-07-01

    The purpose of this article is to review the anatomy, biomechanics, and multimodality imaging findings of common and uncommon distal radioulnar joint (DRUJ), triangular fibrocartilage complex, and distal ulna abnormalities. The DRUJ is a common site for acute and chronic injuries and is frequently imaged to evaluate chronic wrist pain, forearm dysfunction, and traumatic forearm injury. Given the complex anatomy of the wrist, the radiologist plays a vital role in the diagnosis of wrist pain and dysfunction.

  18. Industrial fabrication of an optical security device for document protection using plasmon resonant transmission through a thin corrugated metallic film embedded on a plastic foil

    Science.gov (United States)

    Sauvage-Vincent, Jean; Jourlin, Yves; Tonchev, Svetlen; Veillas, Colette; Claude, Pedri; Parriaux, Olivier

    2012-06-01

    Known since a long time in polymer banknotes and presented in the few years in paper banknotes, the principle of windowed documents has been currently extended to ID documents. We present an innovative solution which combines resonant transmission and Zero Order Device technologies and which is dedicated to improve windows in terms of the overt security level. With this R&D program, Hologram Industries targeted to obtain an overt visual security device that should be readily checked in transmission in the same manner as the established paper watermark. The proposed solution is based on the propagation of resonant modes in a thin continuous corrugated metallic layer embedded (encapsulated) between two dielectric layers of near equal refractive index. The mode of most interest is the Long Range Plasmon Mode. The coupling condition to the Long Range Mode is principally related to the corrugation, the metal layer thickness and the index of the two dielectric layers. If the condition of the mode excitation through the grating is fulfilled, a predetermined wavelength will be coupled to the Long Range Plasmon Mode. This mode will propagate at each metal/dielectric interface with a low loss and will concentrate the electric field inside the metal layer. This effect of coupling enables the transmission of a peak at this wavelength through the metallic layer. It defines the so called "extraordinary resonant transmission".

  19. Volar plating for distal radius fractures--do not trust the image intensifier when judging distal subchondral screw length.

    Science.gov (United States)

    Park, Derek H; Goldie, Boyd S

    2012-09-01

    The use of the volar plate to treat distal radius fractures is increasing but despite the theoretical advantages of a volar approach there have been reports of extensor tendon ruptures due to prominent screw tips protruding past the dorsal cortex. The valley in the intermediate column between Lister tubercle and the sigmoid notch of the distal radius makes it difficult to rely on fluoroscopy to judge screw length. Our aim was to quantify the dimensions of this valley and to demonstrate the danger of relying on intraoperative image intensification fluoroscopy to determine lengths of distal screws. We measured the depth of this valley in the intermediate column of the distal radius in 33 patients with computed tomographic (9 patients) or magnetic resonance image (24 patients) scans of the wrist. There was a consistent valley in all images examined [average 1.8 mm (95% confidence interval, 1.6-2.0 mm)]. Thirty-nine percent of wrists had a valley depth of at least 2 mm. Standard lateral views or rotation of the forearm to obtain oblique views does not identify prominent screw tips; and whatever the rotation of the forearm, screw tips protruding beyond dorsal cortex may look as if it is within the bone when in fact it is out. When drilling we suggest noting the depth at which the drill bit just penetrates dorsal cortex and routinely downsize the distal screw length by 2 mm. We caution against relying on flourosocopy when judging the length of the distal subchondral screws.

  20. Protection and isolation device for pipe maintenance, particularly for pipes of nuclear power plants. Dispositif d'isolement et de protection pour intervention sur tuyauterie, notamment tuyauterie de centrale nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Dohlen, G.; Le Marquis, J.C.; Oberlin, C.

    1984-09-28

    The device is aimed to be introduced and deployed inside a pipe, to collect and remove debris (dust or scraps) or foreign bodies, resulting from the work especially maintenance work being carried out. It comprises a central mast, a deformable sealing joint, mating with the interior of the conduit; a number of arms regularly distributed around the mast, which can be folded back against the mast, to permit introduction of the device into the conduit, each arm supporting the joint at one end and being pivoted on a common base at its other end; mechanical compression apparatus, connected to the mast and the base for deploying the apparatus, and flattening the joint against the interior surface of the conduit to which it is mated; and two sheets of material, each supported at its periphery by the joint, at least one of the sheets being suitable for isolating in sealed manner the space volumes which it delimits. The invention applies to maintenance operations for which the pipes have to be maintained under a controlled inert gas atmosphere, such as sodium circuits maintenance of nuclear power plants.

  1. Nitinol Embolic Protection Filters: Design Investigation by Finite Element Analysis

    Science.gov (United States)

    Conti, Michele; de Beule, Matthieu; Mortier, Peter; van Loo, Denis; Verdonck, Pascal; Vermassen, Frank; Segers, Patrick; Auricchio, Ferdinando; Verhegghe, Benedict

    2009-08-01

    The widespread acceptance of carotid artery stenting (CAS) to treat carotid artery stenosis and its effectiveness compared with surgical counterpart, carotid endarterectomy (CEA), is still a matter of debate. Transient or permanent neurological deficits may develop in patients undergoing CAS due to distal embolization or hemodynamic changes. Design, development, and usage of embolic protection devices (EPDs), such as embolic protection filters, appear to have a significant impact on the success of CAS. Unfortunately, some drawbacks, such as filtering failure, inability to cross tortuous high-grade stenoses, malpositioning and vessel injury, still remain and require design improvement. Currently, many different designs of such devices are available on the rapidly growing dedicated market. In spite of such a growing commercial interest, there is a significant need for design tools as well as for careful engineering investigations and design analyses of such nitinol devices. The present study aims to investigate the embolic protection filter design by finite element analysis. We first developed a parametrical computer-aided design model of an embolic filter based on micro-CT scans of the Angioguard™ XP (Cordis Endovascular, FL) EPD by means of the open source pyFormex software. Subsequently, we used the finite element method to simulate the deployment of the nitinol filter as it exits the delivery sheath. Comparison of the simulations with micro-CT images of the real device exiting the catheter showed excellent correspondence with our simulations. Finally, we evaluated circumferential basket-vessel wall apposition of a 4 mm size filter in a straight vessel of different sizes and shape. We conclude that the proposed methodology offers a useful tool to evaluate and to compare current or new designs of EPDs. Further simulations will investigate vessel wall apposition in a realistic tortuous anatomy.

  2. Arthroplasty of the distal ulna distal in managing patients with post-traumatic disorders of the distal radioulnar joint: measurement of quality of life

    Directory of Open Access Journals (Sweden)

    Marcio Aurélio Aita

    2015-12-01

    Full Text Available ABSTRACT OBJECTIVE: To measure the quality of life and clinical-functional results from patients diagnosed with osteoarthrosis of the distal radioulnar joint who underwent surgical treatment using the technique of total arthroplasty of the ulna, with a total or partial Ascension(r prosthesis of the distal ulna. METHODS: Ten patients were evaluated after 12 months of follow-up subsequent to total or partial arthroplasty of the distal ulna. All of them presented post-traumatic osteoarthrosis and/or chronic symptomatic instability of the distal radioulnar joint. The study was prospective. Seven patients had previously undergone wrist procedures (two cases with Darrach, three with Sauvé-Kapandji and two with ligament reconstruction of the fibrocartilage complex and three presented fractures of the distal ulna that evolved with pain, instability and osteoarthrosis of the distal radioulnar joint. The following were assessed: quality of life (DASH scale; percentage degree of palm grip strength (kgf and pronosupination range of motion in relation to the unaffected side; pain (VAS; return to work; subjective evaluation of radiography; and complications. RESULTS: The patients presented a mean range of motion of 174.5° (normal side: 180°. Quality of life was analyzed by applying the DASH questionnaire and the mean value found was 5.9. The mean pain score using the VAS was 2.3. The mean degree of palm grip strength (kgf was 50.7, which represented 90.7% of the strength on the unaffected side. The complication rate was 10%: this patient presented slight dorsal instability of the ulna and persistent pain, and did not return to work. This patient is still being followed up in the outpatient clinic and occupational therapy sector, with little improvement. He does not wish to undergo a new procedure. The mean length of follow-up was 16.8 months, with a minimum of 10 and maximum of 36 months. CONCLUSION: This concept is subject to the test of time

  3. Intake of specific nonfermented soy foods may be inversely associated with risk of distal gastric cancer in a Chinese population.

    Science.gov (United States)

    Kweon, Sun-Seog; Shu, Xiao-Ou; Xiang, Yongbing; Cai, Hui; Yang, Gong; Ji, Bu-Tian; Li, Honglan; Gao, Yu-Tang; Zheng, Wei; Epplein, Meira

    2013-11-01

    Because the association between soy consumption and gastric cancer is inconsistent, we evaluated the putative preventive effect of soy food on gastric cancer risk in the Shanghai Women's and Men's Health Studies, comprising a total of 128,687 participants. Intake of nonfermented soy foods was estimated using 2 validated food-frequency questionnaires. HRs were calculated with 95% CIs for intake amounts of total nonfermented soy food intake, soy protein, and isoflavones as well as individual soy food groups using Cox proportional hazards regression. A total of 493 distal gastric cancer cases were identified by 2010. Although all risk estimates for summary measures of soy food intake above the lowest quartile (quartile 1) were suggestive of a protective effect, no statistically significant associations with risk of distal gastric cancer were found. Among the separate soy food groups, significant reductions in risk of distal gastric cancer by increasing intake of tofu were found in men in quartile 2 (HR: 0.59; 95% CI: 0.40, 0.86), quartile 3 (HR: 0.62; 95% CI: 0.44, 0.88), and quartile 4 (HR: 0.64; 95% CI: 0.42, 0.99), resulting in a significant trend (P-trend = 0.02). Dry bean intake was also inversely associated with decreased risk of gastric cancer, but in postmenopausal women only [quartile 2 (HR: 0.54; 95% CI: 0.30, 0.96); quartile 3 (HR: 0.90; 95% CI: 0.64, 1.27); and quartile 4 (HR: 0.63; 95% CI: 0.43, 0.91)], resulting in a significant trend (P-trend = 0.03). Overall, our study found no statistically significant association between nonfermented soy food intake and distal gastric cancer risk, though the data supported the hypothesis that tofu may protect against distal gastric cancer in men and dry bean consumption may decrease the risk of gastric cancer in postmenopausal women.

  4. [TREATMENT OF PRONATION EXTERNAL ROTATION ANKLE FRACTURE COMBINED WITH SEPARATION OF DISTAL TIBIOFIBULAR SYNDESMOSIS].

    Science.gov (United States)

    Wu, Benwen; Ding, Zhenqi; Huang, Guofeng; Liu, Guojun; Cai, Zhemin; Ding, Luobin; Li, Xiang

    2016-09-08

    To evaluate the difference between using and not using syndesmotic screw to treat pronation external rotation (PER) ankle fracture combined with separation of distal tibiofibular syndesmosis. Between April 2011 and October 2014, 46 cases of PER ankle fracture combined with separation of distal tibiofibular syndesmosis were treated, and syndesmotic screw was used in 24 cases (fixation group) and syndesmotic screw was not used in 22 cases (non-fixation group). There was no significant difference in gender, age, weight, cause of injury, side, injury to operation time, and fracture type between 2 groups ( P >0.05). The time for full weight-bearing, fracture healing time, and complications were recorded after operation. Anteroposterior and lateral X-ray films were taken to measure the tibiofibular overlap (TBOL) and tibiofibular clear space (TBCS). Baird-Jackson score was used to evaluate functional recovery of the ankle. All incision healed by first intention without complications. The cases were followed up 13-18 months (mean, 15.2 months) in 2 groups. The time for full weight-bearing was 8-12 weeks (median, 11 weeks) in fixation group, which was significantly later than that in non-fixation group (range, 6-10 weeks; median, 8 weeks) ( Z =-5.049, P =0.000). X-ray examination showed reduction of separation of distal tibiofibular syndesmosis. All fractures healed. The fracture healing time was (13.83±1.37) weeks in fixation group, and was (13.91±1.31) weeks in non-fixation group, showing no significant difference ( t =-0.191, P =0.945). No separation of distal tibiofibular syndesmosis, delayed union, nonunion, loosening, or breakage of fixation devices was observed in 2 groups. There was no significant difference in TBOL, TBCS, Baird-Jackson score and the excellent and good rate between 2 groups ( P >0.05). If the medial, lateral, and posterior structures of the ankle could be repaired according to injury, no significant influence on functional outcome of ankle or

  5. Limited distal organelles and synaptic function in extensive monoaminergic innervation.

    Science.gov (United States)

    Tao, Juan; Bulgari, Dinara; Deitcher, David L; Levitan, Edwin S

    2017-08-01

    Organelles such as neuropeptide-containing dense-core vesicles (DCVs) and mitochondria travel down axons to supply synaptic boutons. DCV distribution among en passant boutons in small axonal arbors is mediated by circulation with bidirectional capture. However, it is not known how organelles are distributed in extensive arbors associated with mammalian dopamine neuron vulnerability, and with volume transmission and neuromodulation by monoamines and neuropeptides. Therefore, we studied presynaptic organelle distribution in Drosophila octopamine neurons that innervate ∼20 muscles with ∼1500 boutons. Unlike in smaller arbors, distal boutons in these arbors contain fewer DCVs and mitochondria, although active zones are present. Absence of vesicle circulation is evident by proximal nascent DCV delivery, limited impact of retrograde transport and older distal DCVs. Traffic studies show that DCV axonal transport and synaptic capture are not scaled for extensive innervation, thus limiting distal delivery. Activity-induced synaptic endocytosis and synaptic neuropeptide release are also reduced distally. We propose that limits in organelle transport and synaptic capture compromise distal synapse maintenance and function in extensive axonal arbors, thereby affecting development, plasticity and vulnerability to neurodegenerative disease. © 2017. Published by The Company of Biologists Ltd.

  6. Fractures of the distal radius in children: A retrospective evaluation

    Directory of Open Access Journals (Sweden)

    Selma Yazıcı

    2012-06-01

    Full Text Available Objectives: This study designed to evaluate the resultsof treatment, closed reduction and percutaneous wires, ofthe distal radius fractures in children.Materials and methods: A retrospective analysis wascarried out in children aged between 5-15 years who presentedwith a displaced fracture of the distal radius to ourhospital. They were initially treated with closed reductionand cast immobilization. If the fractures redisplaced treatedby percutaneous Kirschner (K- wire with scope undera general anaesthesia.Results: Totally 104 patients, who have distal radius fractureswere treated by closed reduction and immobilizationin a plaster cast. 13 patient who have distal radiusfractures were treated by closed reduction under generalanaesthesia and fixed by percutaneous Kirschner (K-wire. Patients with impaired the alignment of the fracturein late period were usually completely displaced fractures.(n=5, 4,3%, in early period, completely displaced fractures(n=5, 4,3% are superior to partial displaced fractures(n=2, 1,7%.Conclusion: In our study, when children with distal radiusfracture first come, they were treated by closed reductionand immobilization in a plaster cast. We thought that inredisplaced fractures patients were suitable for the closedreduction with percutaneous wire treatment.

  7. Mobile device security for dummies

    CERN Document Server

    Campagna, Rich; Krishnan, Ashwin

    2011-01-01

    The information you need to avoid security threats on corporate mobile devices Mobile devices have essentially replaced computers for corporate users who are on the go and there are millions of networks that have little to no security. This essential guide walks you through the steps for securing a network and building a bulletproof framework that will protect and support mobile devices in the enterprise. Featuring real-world case scenarios, this straightforward guide shares invaluable advice for protecting mobile devices from the loss of sensitive and confidential corporate informati

  8. Laparoscopic versus open distal pancreatectomy for pancreatic cancer.

    Science.gov (United States)

    Riviere, Deniece; Gurusamy, Kurinchi Selvan; Kooby, David A; Vollmer, Charles M; Besselink, Marc G H; Davidson, Brian R; van Laarhoven, Cornelis J H M

    2016-04-04

    Surgical resection is currently the only treatment with the potential for long-term survival and cure of pancreatic cancer. Surgical resection is provided as distal pancreatectomy for cancers of the body and tail of the pancreas. It can be performed by laparoscopic or open surgery. In operations on other organs, laparoscopic surgery has been shown to reduce complications and length of hospital stay as compared with open surgery. However, concerns remain about the safety of laparoscopic distal pancreatectomy compared with open distal pancreatectomy in terms of postoperative complications and oncological clearance. To assess the benefits and harms of laparoscopic distal pancreatectomy versus open distal pancreatectomy for people undergoing distal pancreatectomy for pancreatic ductal adenocarcinoma of the body or tail of the pancreas, or both. We used search strategies to search the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, Science Citation Index Expanded and trials registers until June 2015 to identify randomised controlled trials (RCTs) and non-randomised studies. We also searched the reference lists of included trials to identify additional studies. We considered for inclusion in the review RCTs and non-randomised studies comparing laparoscopic versus open distal pancreatectomy in patients with resectable pancreatic cancer, irrespective of language, blinding or publication status.. Two review authors independently identified trials and independently extracted data. We calculated odds ratios (ORs), mean differences (MDs) or hazard ratios (HRs) along with 95% confidence intervals (CIs) using both fixed-effect and random-effects models with RevMan 5 on the basis of intention-to-treat analysis when possible. We found no RCTs on this topic. We included in this review 12 non-randomised studies that compared laparoscopic versus open distal pancreatectomy (1576 participants: 394 underwent laparoscopic distal pancreatectomy and 1182

  9. Giant Cell Tumour of the Distal Ulna: A Rare Presentation

    Directory of Open Access Journals (Sweden)

    Ruben Jaya Kumar

    2011-07-01

    Full Text Available Giant-cell tumour (GCT of bone, a primary yet locally aggressive benign tumour, commonly affects patients between the ages of 20 and 40 years, with the peak incidence occurring in the third decade. Women are affected slightly more than men. The distal end of the ulna is an extremely uncommon site for primary bone tumours in general and giant cell tumours in particular. Wide resection of the distal ulna is the recommended treatment for GCT in such locations. Radio-ulna convergence and dorsal displacement of the ulna stump are known complications following ulna resection proximal to the insertion of the pronator quadratus. This leads to reduction in grip power and forearm rotatory motion. Stabilization of the ulna stump with extensor carpi ulnaris (ECU tendon after wide resection of the tumour has been described in the literature. We report a case of GCT of distal end of ulna treated with wide resection and stabilization with ECU tendon.

  10. Segmental reversal of distal small intestine in short bowel syndrome

    DEFF Research Database (Denmark)

    Grave, Pernille Kock; Thomsen, Sabrina Valentin; Clark, Pia Susanne

    2018-01-01

    were the influence on cell proliferation and mucosal architecture shown by histological analysis. Methods: Sixteen piglets underwent a 60% resection of the distal small intestine and were randomized into two groups. Group 1 short bowel syndrome alone (SBS) (n = 8) and group 2 with reversal of a distal...... small intestinal segment (SBS-RS) (n = 8). Body weight was measured daily and the pigs were euthanized after 1 month. Crypt depths, villus heights and muscle layers thicknesses were measured. For the evaluation of microvilli of the brush border of the epithelium and cell proliferation...... was found in the SBS group and increase in the thickness of the circular and longitudinal muscle layers in the SBS-RS group. In the distal ileal segment the longitudinal muscle layer thicknesses were increased in the SBS group. Otherwise, no significant changes were found. Conclusion: Reversal of a 20-cm...

  11. Fractures of the distal tibia treated with polyaxial locking plating.

    Science.gov (United States)

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2009-03-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial infections and evidence of delayed wound healing. Using the American Orthopaedic Foot and Ankle Society ankle score, the average functional score was 87.3 points (of 100 total possible points). Our results show the polyaxial locking plates, which offer more fixation versatility, may be a reasonable treatment option for distal tibia fractures with very short metaphyseal segments.

  12. [Intramedullary nailing of the distal tibia illustrated with the Expert(TM) tibia nail].

    Science.gov (United States)

    El Attal, R; Hansen, M; Rosenberger, R; Smekal, V; Rommens, P M; Blauth, M

    2011-12-01

    Restoration of axis, length, and rotation of the lower leg. Sufficient primary stability of the osteosynthesis for functional aftercare and to maintain joint mobility. Good bony healing in closed and open fractures. Closed and open fractures of the tibia and complete lower leg fractures distal to the isthmus (AO 42), extraarticular fractures of the distal tibia (AO 43 A1/A2/A3), segmental fractures of the tibia with a fracture in the distal tibia, and certain intraarticular fractures of the distal tibia without impression of the joint line with the use of additional implants (AO 43 C1) Patient in reduced general condition (e.g., bed ridden), flexion of the knee of less than 90°, patients with knee arthroplasty of the affected leg, infection in the area of the nail's insertion, infection of the tibial cavity, complex articular fractures of the proximal or distal tibia with joint depression. Closed reduction of the fracture preferably on a fracture table or using a distractor or an external fixation frame. If necessary, use pointed reduction clamps or sterile drapery. In some cases, additional implants like percutaneous small fragment screws, poller screws or k-wires are helpful. Open reduction is rarely necessary and must be avoided. Opening of the proximal tibia in line with the medullary canal. Canulated insertion of the Expert(TM) tibia nail (ETN; Synthes GmbH, Oberdorf, Switzerland) with reaming of the medullary canal. Control of axis, length, and rotation. Distal interlocking with the radiolucent drill and proximal interlocking with the targeting device. Immediate mobilization of ankle and knee joint. Mobilization with 20 kg weight-bearing with crutches. X-ray control 6 weeks postoperatively and increased weight-bearing depending on the fracture status. In cases with simple fractures, good bony contact, or transverse fracture pattern, full weight-bearing at the end of week 6 is targeted. Between July 2004 and May 2005, 180 patients were included in a

  13. Minimally Invasive Distal Pancreatectomy: Review of the English Literature.

    Science.gov (United States)

    Wang, Kai; Fan, Ying

    2017-02-01

    Recently, the superiority of the minimally invasive approach, which results in a better cosmetic result, faster recovery, and shorter length of hospital stay, is a technique that has been progressively recognized as it has developed. And the minimally invasive approach has been applied to distal pancreatectomy (DP), which is a standard method for the treatment of benign, borderline, and part of malignant lesions of the pancreatic body and tail. This article aims to analyze the types, postoperative recovery, and outcomes of laparoscopic distal pancreatectomy (LDP). A systematic search of the scientific literature was performed using PubMed, EMBASE, online journals, and the Internet for all publications on LDP. Articles were selected if the abstract contained patients who underwent LDP for pancreatic diseases. All selected articles were reviewed and analyzed. If there were no contraindications for LDP, this operation is suitable for benign, borderline, or malignant tumors of the pancreatic body and tail, which should try to be performed with preservation of the spleen. LDP is safe and feasible under some conditions to experienced surgeon. Single-incision laparoscopic distal pancreatectomy (S-LDP) and robotic laparoscopic distal pancreatectomy (R-LDP) perioperative outcomes are similar with conventional multi-incision laparoscopic distal pancreatectomy (C-LDP). And the advantages of S-LDP and R-LDP require further exploration. With the application of enhanced recovery program (ERP), length of hospital stay and costs are reduced. LDP is safe and feasible under some conditions. Compared with open distal pancreatectomy, LDP has a lot of advantages; a trend was observed for LDP to replace traditional open surgery. LDP combined with ERP is expected to become standard in the treatment of pancreatic body and tail lesions.

  14. Laparoscopic distal pancreatectomy for adenocarcinoma: safe and reasonable?

    Science.gov (United States)

    Postlewait, Lauren M.

    2015-01-01

    As a result of technological advances during the past two decades, surgeons now use minimally invasive surgery (MIS) approaches to pancreatic resection more frequently, yet the role of these approaches for pancreatic ductal adenocarcinoma resections remains uncertain, given the aggressive nature of this malignancy. Although there are no controlled trials comparing MIS technique to open surgical technique, laparoscopic distal pancreatectomy for pancreatic adenocarcinoma is performed with increasing frequency. Data from retrospective studies suggest that perioperative complication profiles between open and laparoscopic distal pancreatectomy are similar, with perhaps lower blood loss and fewer wound infections in the MIS group. Concerning oncologic outcomes, there appear to be no differences in the rate of achieving negative margins or in the number of lymph nodes (LNs) resected when compared to open surgery. There are limited recurrence and survival data on laparoscopic compared to open distal pancreatectomy for pancreatic adenocarcinoma, but in the few studies that assess long term outcomes, recurrence rates and survival outcomes appear similar. Recent studies show that though laparoscopic distal pancreatectomy entails a greater operative cost, the associated shorter length of hospital stay leads to decreased overall cost compared to open procedures. Multiple new technologies are emerging to improve resection of pancreatic cancer. Robotic pancreatectomy is feasible, but there are limited data on robotic resection of pancreatic adenocarcinoma, and outcomes appear similar to laparoscopic approaches. Additionally fluorescence-guided surgery represents a new technology on the horizon that could improve oncologic outcomes after resection of pancreatic adenocarcinoma, though published data thus far are limited to animal models. Overall, MIS distal pancreatectomy appears to be a safe and reasonable approach to treating selected patients with pancreatic ductal

  15. Biocarbon device for cutaneous ureterostomy.

    Science.gov (United States)

    Pow-Sang, J; Ojeda, J; Benavente, V; Pow-Sang, J

    1984-01-01

    The surgical technique for a new alternative to urinary diversion is described. The biocarbon conduit is an inert device implanted in the abdominal wall. Its inner end is anastomosed to the distal ureter, and the outlet is over the abdominal skin and connected to a collector tube into a urinary bag. Twenty implants were performed between March, 1980, and July, 1981. Seventeen patients had carcinoma of the uterine cervix, and 3 had carcinoma of the urinary bladder (age range 34 to 79 years). All had severe urinary tract infection, retrodilation, and were in poor general physical condition. Eight fistulas developed in the 20 implants.

  16. Neglected Distal Humeral Epiphyseal Injury - Two Case Reports

    Directory of Open Access Journals (Sweden)

    Dr. Pankaj Kumar

    2008-07-01

    Full Text Available Distal humeral epiphyseal separation is an uncommon injury in children, which can be missed or misdiagnosed at initial presentation. Awareness of this injury and appropriate radiological assessment helps in proper management. Neglected cases because of inappropriate diagnosis can result in cubitus varus deformity. Full range of movements of elbow can be achieved if properly diagnosed and managed. We present two cases of neglected distal humeral epiphyseal injury in children that resulted in cubitus varus deformity in one case. Full range of movements was achieved in both cases after proper management.

  17. Distal vertebral artery reconstruction when managing vertebrobasilar insufficiency

    Directory of Open Access Journals (Sweden)

    D. M. Galaktionov

    2017-11-01

    Full Text Available This article presents a literature review devoted to the reconstruction of the distal vertebral artery and a clinical case of successful surgical treatment of a patient suffering from vertebrobasilar insufficiency caused by occlusion of the vertebral artery in a proximal segment. The external carotid artery-distal vertebral artery bypass was performed by using the radial artery.Received 27 February 2017. Revised 25 July 2017. Accepted 3 August 2017.Funding: The study did not have sponsorship.Conflict of interest: The authors declare no conflict of interest. 

  18. Robotic spleen-preserving distal pancreatectomy. A case report.

    Science.gov (United States)

    Vasilescu, C; Sgarbura, O; Tudor, S; Herlea, V; Popescu, I

    2009-01-01

    Distal pancreatectomy (DP) is the removal of the pancreatic tissue at the left side of the superior mesenteric vein and it is traditionally approached by an open or laparoscopic exposure. Preservation of the spleen is optional but appears to have a better immunological outcome. We present the case of a 53-year old patient with a 2.4/2.2 tumor located in the tail of the pancreas, with high tumour marker values for whom we decided to perform a robotic spleen-preserving distal pancreatectomy (RSPDP). The postoperative outcome was satisfactory. In conclusion, we recommend this type of approach for small pancreatic tail lesions.

  19. Locking plates in distal humerus fractures: study of 43 patients

    Directory of Open Access Journals (Sweden)

    Gupta Rakesh Kumar

    2013-08-01

    Full Text Available 【Abstract】Objective: The treatment of multi-fragmentary, intraarticular fractures of the distal humerus is difficult, even in young patients with bone of good quality. Small distal fragment, diminished bone mineral quality and increased trauma-associated joint destruction make stable joint reconstruction more problematic. The anatomically preshaped locking plates allow angular stable fixation for these complex fractures. We evaluated functional results of patients treated with open reduction and internal fixation with distal humerus locking plates for complex distal hu-merus fractures. Methods: Forty-three consecutive patients with ar-ticular fractures of the distal humerus were treated by open reduction and internal fixation with AO distal humerus plate system and locking reconstruction plates. Forty patients were available for the final outcome analysis. According to AO/ASIF classification, there were 2 cases of type A2, 4 cases of type A3, 1 case of type B1, 1 case of type B2, 14 cases of type C1, 7 cases of type C2 and 11 cases of type C3. Open reduction with triceps splitting technique was used in all patients. The clinical and radiographic follow-up was performed and outcome measures included pain assessment, range of motion, and Mayo elbow performance score. Results: Forty patients were available for the final outcome analysis. There were 29 males and 11 females with an average age of 38.4 years (18-73 years. Clinical and ra-diological consolidation of the fracture was observed in all cases at an average of 11.6 weeks (9-14 weeks. The average follow-up was 12 months (10-18 months. Using the Mayo elbow performance score the results obtained were graded as excellent or good results in 33 patients (82.5%. One pa-tient had superficial infection, and 4 had myositis ossificans. There were no cases of primary malposition or secondary displacement, implant failure or ulnar neuropathy. Conclusion: Anatomically preshaped distal humerus locking

  20. Traumatisk distal humerus-epifysiolyse hos nyfødt

    DEFF Research Database (Denmark)

    Al-Aubaidi, Zaid; Nielsen, Keld Daubjerg

    2010-01-01

    Traumatic distal humerus epiphysiolysis (TDHE) is a rare injury in infants with an incidence of about 1:35,000 births. It is primarily a birth injury, but it is also seen in cases of battered child syndrome. Because of its rare occurrence and the diagnostic difficulties, the lesion may be overloo......Traumatic distal humerus epiphysiolysis (TDHE) is a rare injury in infants with an incidence of about 1:35,000 births. It is primarily a birth injury, but it is also seen in cases of battered child syndrome. Because of its rare occurrence and the diagnostic difficulties, the lesion may...

  1. Primary bone lymphoma of the distal tibia mimicking brodie's abscess

    International Nuclear Information System (INIS)

    Park, Jina; Lee, Seung Hun; Joo, Kyung Bin; Park, Chan Kum

    2014-01-01

    The 'penumbra sign' on an unenhanced T1-weighted image is a well-known characteristic of Brodie's abscess, and this sign is extremely helpful for discriminating subacute osteomyelitis from other bone lesions. We present a case of primary bone lymphoma of the distal tibia mimicking subacute osteomyelitis with Brodie's abscess in a 50-year-old woman. Initial radiographs and MRI showed a lesion in the distal tibia consistent with Brodie's abscess with the penumbra sign. Histopathological examination of the surgical biopsy specimen confirmed the presence of a diffuse large B-cell lymphoma involving the bone.

  2. Nontraumatic osteonecrosis of the distal pole of the scaphoid

    Directory of Open Access Journals (Sweden)

    Bhavuk Garg

    2011-01-01

    Full Text Available Post traumatic osteonecrosis of distal pole of scaphoid is very rare. We present a case of 34 years old male, drill operator by occupation with nontraumatic osteonecrosis of distal pole of the scaphoid. The patient was managed conservatively and was kept under regular follow-up every three months. The patient was also asked to change his profession. Two years later, the patient had no pain and had mild restriction of wrist movements (less than 15 degrees in either direction. The radiographs revealed normal density of the scaphoid suggesting revascularization.

  3. Osteoblastoma-like osteosarcoma of the distal tibia

    Energy Technology Data Exchange (ETDEWEB)

    Abramovici, Luigia; Steiner, German C. [Department of Pathology and Laboratory Medicine, Hospital for Joint Diseases, New York, NY (United States); Kenan, Samuel [Department of Orthopaedic Oncology Surgery, Hospital for Joint Diseases, New York, NY (United States); Hytiroglou, Prodromos [Aristotle University, Thessaloniki (Greece); Rafii, Mahvash [Department of Radiology, Hospital for Joint Diseases, New York, NY (United States)

    2002-03-01

    We report a case of a 14-year-old boy with an intracompartmental lytic lesion with poorly defined margins in the right distal tibia that was originally treated with curettage and bone grafting. Histologic examination showed an osteoblastic tumor with unusual features, which was found on consultation to be an osteoblastoma-like osteosarcoma, a rare, low-grade variant of osteosarcoma. Subsequently, the patient underwent en bloc resection of the distal tibia, which was replaced with vascularized bone graft and followed by chemotherapy. Two years later, he is alive with lung metastases. (orig.)

  4. Osteoblastoma-like osteosarcoma of the distal tibia

    International Nuclear Information System (INIS)

    Abramovici, Luigia; Steiner, German C.; Kenan, Samuel; Hytiroglou, Prodromos; Rafii, Mahvash

    2002-01-01

    We report a case of a 14-year-old boy with an intracompartmental lytic lesion with poorly defined margins in the right distal tibia that was originally treated with curettage and bone grafting. Histologic examination showed an osteoblastic tumor with unusual features, which was found on consultation to be an osteoblastoma-like osteosarcoma, a rare, low-grade variant of osteosarcoma. Subsequently, the patient underwent en bloc resection of the distal tibia, which was replaced with vascularized bone graft and followed by chemotherapy. Two years later, he is alive with lung metastases. (orig.)

  5. Distal renal tubular acidosis and amelogenesis imperfecta: A rare association

    Directory of Open Access Journals (Sweden)

    P Ravi

    2013-01-01

    Full Text Available Renal tubular acidosis (RTA is characterized by a normal anion gap with hyperchloremic metabolic acidosis. Primary distal RTA (type I is the most common RTA in children. Childhood presentation of distal RTA includes vomiting, failure to thrive, metabolic acidosis, and hypokalemia. Amelogenesis imperfecta (AI represents a condition where the dental enamel and oral tissues are affected in an equal manner resulting in the hypoplastic or hypopigmented teeth. We report a 10-year-old girl, previously asymptomatic presented with the hypokalemic paralysis and on work-up found out to have type I RTA. The discoloration of teeth and enamel was diagnosed as AI.

  6. Modified distal shoe appliance--fabrication and clinical performance.

    Science.gov (United States)

    Gujjar, Kumar Raghav; Indushekar, K R; Amith, H V; Sharma, Shefali Li

    2012-01-01

    When the primary second molar is prematurely lost, mesial movement and migration of the permanent first molar often occurs. This is one of the most difficult problems of the developing dentition confronted by pediatric dentists. Use of a space maintainer that will guide the permanent first molar into its normal position is indicated. In cases with bilateral premature loss of primary molars, the conventional design of distal shoe poses a variety of problems and, therefore, necessitates a customized design for the eruption guidance of permanent first molars. The purpose of this case report is to discuss an innovative design of a distal shoe appliance, which was used with good clinical results.

  7. Screening renal stone formers for distal renal tubular acidosis

    DEFF Research Database (Denmark)

    Osther, P J; Hansen, A B; Røhl, H F

    1989-01-01

    A group of 110 consecutive renal stone formers were screened for distal renal tubular acidosis (RTA) using morning fasting urinary pH (mfUpH) levels followed by a short ammonium chloride loading test in patients with levels above 6.0. In 14 patients (12.7%) a renal acidification defect was noted...... RTA in renal stone formers. Regardless of whether the acidification defect is primary or secondary to stone formation, however, all renal stone formers with distal RTA can expect to benefit from prophylactic alkaline therapy and it is recommended that the screening procedure, which is easy to use...

  8. 33 CFR 159.75 - Overcurrent protection.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Overcurrent protection. 159.75...) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.75 Overcurrent protection. Overcurrent protection must be provided within the unit to protect subcomponents of the device if the...

  9. Digital protection in power plants. Electrical unit and line protection. Digital protection systems for NPP

    International Nuclear Information System (INIS)

    Kaczmarek, A.

    2000-01-01

    In this presentation author deals with the digital protection systems for nuclear power plants. The evolution of protection devices, protection concept for power plants, concept of functional redundancy, references for digital protection, benefits for the customer well as concept fault recorder are presented. (author)

  10. Distally based superficial sural artery flap for soft tissue coverage in the distal 2/3 of leg and foot

    Directory of Open Access Journals (Sweden)

    Kamath B

    2005-01-01

    Full Text Available Background: Skin coverage for defects in the lower 2/3 of leg, ankle region and posterior heel has always been a difficult challenge for reconstructive surgeon. Methods: We describe our experience with the distally based superficial sural artery flap coverage in 48 patients with moderate sized defects in these difficult areas. Results: One out of 48 flaps (in 48 patients was lost totally and 3 suffered marginal necrosis which did not require any secondary procedure. These complications could have been avoided by proper selection of cases and refining technical skills. Conclusion: This simple procedure could be an important and versatile tool for any reconstructive surgeon in providing skin coverage in the distal leg and proximal foot. Preservation of major arteries of the lower limb, minimal donor defect, relatively uninjured donor area in compound fracture or poly trauma involving distal leg are some of the advantages of the flap.

  11. Protection of electronic circuits from overvoltages

    CERN Document Server

    Standler, Ronald B

    1989-01-01

    Practical rules and strategies designed to protect electronic systems from damage by transient overvoltages include symptoms and threats, remedies, protective devices and their applications, and validation of protective measures. 1989 edition.

  12. Photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  13. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  14. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  15. Lesion-Related Carotid Angioplasty and Stenting with Closed-Cell Design without Embolic Protection Devices in High-Risk Elderly Patients-Can This Concept Work Out? A Single Center Experience Focusing on Stent Design.

    Science.gov (United States)

    Hopf-Jensen, Silke; Marques, Leonardo; Preiß, Michael; Müller-Hülsbeck, Stefan

    2014-12-01

    To compare the performance differences of three carotid artery stents in high-risk elderly patients without embolic protection devices (EPDs) on the basis of stent design, procedure-related complications, conveniences in handling, in-stent restenosis, 30-day outcome, and long-term follow-up. A total of 101 symptomatic internal carotid stenoses of 94 patients were prospectively treated with stent-protected angioplasty to 94 patients. Three closed-cell stents, one of those being hybrid cell design, were chosen depending on vascular anatomy: curved vessel, lesion length > 1 cm: 64 Carotid Wallstent (Boston Scientific, Natick, MA); curved vessel, lesion length  1 cm: 16 Xact (Vascular Abbott, Santa Clara, CA). Comparisons of demographics, procedures, and outcomes were performed. The mean age of patients was 73.1 years (standard deviation [SD], ± 7.9; range, 58-87 years), 71% of the patients were older than 70 years and 20% were octogenarians. Male/female ratio was 3.1:1. About 13.9% (14/101) had contralateral internal carotid artery occlusion. Overall peri-interventional complication rate was 2.9% and 30-day mortality rate was 1%. During the long-term follow-up (34 months, range 1-59) no ipsilateral stroke was documented. Ten deaths (three after MI) were recognized. Two in-stent restenosis were detected (> 70% North American Symptomatic Carotid Endarterectomy Trial) during follow-up, one patient was detected with previous carotid endarterectomy. Especially, if individual anatomical variance is considered, lesion-related stent-protected carotid angioplasty with lesion-adapted closed-cell design is an effective, reliable, safe, and comprehensible treatment option in symptomatic patients. Even without EPDs, the rate of complications is low, when compared with symptomatic carotid artery stenosis described in the literature. In-stent restenosis seems to play no significant role in follow-up.

  16. Radiation beans characterization and implantation for study of lead equivalent individual protection device used in radiodiagnostic practices; Caracterizacao e implantacao de feixes de radiacao para estudo de dispositivos de protecao individual com equivalencia em chumbo utilizados em praticas de radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Leslie Silva

    2004-07-01

    The protective shielding (IPC) must be used by occupationally exposed professionals, patients and volunteers, in order to optimize the doses who receive due to radiological practices. International and national norms establish the methodology to be adopted for determination of the IPC attenuation. In this work, the IPC had been submitted to X-rays beams with known characteristics, standardized for determination of their attenuation equivalent thickness by comparison to an experimental lead attenuation slope. This comparison technique allowed insurance estimative of the IPC attenuation equivalent thickness in mm of lead. Thus, it was possible to verify the conformity of the attenuation equivalent thickness determined experimentally and the value of the thickness indicated by the manufacturer. To carry out this work, it was necessary the implementation of experimental setups stated in the specifics norms, the study of the X-rays beams original features and the determination of combined additional filters, in order to allow the X-ray equipment used operates in compliance with Norm IEC 61331-1 IEC. The radiation quality selected is characterized by a 100 kV voltage and a 0.25 mm of copper overall filtration. The implementation of this radiation quality it was carried through of its first and second HVL (Half Value Layer). Thus, a methodology according to the international Norms has been implemented in the laboratory. The results of the present work provide suitable and useful information about radiation beams features related to the determination techniques of the attenuation properties. Once implemented the procedures for conformity evaluation of the protection devices, it will be possible to carry out specific quality control tests, which will be helpful to manufacturers, customers, as well as authorities in the radiological protection and health areas. (author)

  17. Arthrodesis of the thumb interphalangeal joint and finger distal interphalangeal joints with a headless compression screw.

    Science.gov (United States)

    Cox, Christopher; Earp, Brandon E; Floyd, W Emerson; Blazar, Philip E

    2014-01-01

    To study the results of using a small, headless compression screw (AcuTwist) for thumb interphalangeal (IP) joint and finger distal interphalangeal (DIP) joint arthrodeses. Between November 2007 and January 2012, 48 primary arthrodeses of the thumb IP joint or DIP joint in the other digits were performed in 29 consecutive patients with AcuTwist devices. Indications for arthrodesis included 19 cases of osteoarthritis in 25 fingers, 3 cases of lupus in 9 fingers, 2 cases of post-traumatic osteoarthritis in 2 fingers, and 1 case and finger each of acute trauma, neuromuscular disorder, postinfectious osteoarthritis, boutonniere deformity, and Dupuytren contracture. Charts were reviewed for clinical data, and radiographs were assessed for alignment and healing. Age averaged 59 years and follow-up averaged 12 months (range, 2-50 mo). Union occurred in 43 out of 46 fingers (94%). There were no cases of nail deformity, wound complications, tip hypersensitivity, or clinically notable malalignment. Three arthrodeses failed to fuse, including 2 asymptomatic nonunions and 1 fixation loss requiring revision with autograft. The complication rate was 9%. Distal digital joint arthrodesis with the AcuTwist resulted in a fusion rate of 94% with a complication rate of 9%. Our rate of fusion compares favorably with prior series using other methods of fixation. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  18. Genetics Home Reference: CAV3-related distal myopathy

    Science.gov (United States)

    ... gene causes a peculiar form of distal myopathy. Neurology. 2002 Jan 22;58(2):323-5. Erratum in: Neurology 2002 Mar 12;58(5):839. Itoyoma Y [ ... 3 cause four distinct autosomal dominant muscle diseases. Neurology. 2004 Feb 24;62(4):538-43. Review. ...

  19. Urethral advancement procedure in the treatment of primary distal ...

    African Journals Online (AJOL)

    advancement in the repair of primary distal penile hypospadias with regard to feasibility, complication rates .... stones and growth, and any associated congenital anomaly. Meticulous local examination was performed ... with a tourniquet placed on the root of the penis. A submeatal crescent-like incision was performed a few.

  20. Neglected distal humeral epiphyseal injury - Two Case Reports ...

    African Journals Online (AJOL)

    We present two cases of neglected distal humeral epiphyseal injury in children that resulted in cubitus varus deformity in one case. Full range of movements was achieved in both cases after proper management. Keywords: Neglected epiphyseal injury; Cubitus varus; Diagnosis; Treatment Internet Journal of Medical Update ...

  1. Evaluation of Various Filling Techniques in Distal Canals of ...

    African Journals Online (AJOL)

    2017-03-06

    Mar 6, 2017 ... How to cite this article: Dumani A, Yilmaz S, Yoldas O, Kuden C. Evaluation ... Niger J. Clin Pract 2017;20:307-12. This is an open access article distributed ... in oval-shaped distal canals of mandibular molars was inadequate.

  2. Social Support Contributes to Outcomes following Distal Radius Fractures

    Directory of Open Access Journals (Sweden)

    Caitlin J. Symonette

    2013-01-01

    Full Text Available Background. Distal radius fractures are the most common fracture of the upper extremity and cause variable disability. This study examined the role of social support in patient-reported pain and disability at one year following distal radius fracture. Methods. The Medical Outcomes Study Social Support Survey was administered to a prospective cohort of 291 subjects with distal radius fractures at their baseline visit. Pearson correlations and stepwise linear regression models (F-to-remove 0.10 were used to identify whether social support contributes to wrist fracture outcomes. The primary outcome of pain and disability at one year was measured using the Patient Rated Wrist Evaluation. Results. Most injuries were low energy (67.5% and were treated nonoperatively (71.9%. Pearson correlation analysis revealed that higher reported social support correlated with improved Patient Rated Wrist Evaluation scores at 1 year, r(n=181=-0.22, P<0.05. Of the subscales within the Social Support Survey, emotional/informational support explained a significant proportion of the variance in 1-year Patient Rated Wrist Evaluation scores, R2=4.7%, F (1, 181 = 9.98, P<0.05. Conclusion. Lower emotional/informational social support at the time of distal radius fracture contributes a small but significant percentage to patient-reported pain and disability outcomes.

  3. Simultaneous bilateral distal biceps tendon repair: case report

    Directory of Open Access Journals (Sweden)

    Thiago Medeiros Storti

    Full Text Available ABSTRACT Simultaneous bilateral rupture of the distal biceps tendon is a rare clinical entity, seldom reported in the literature and with unclear therapeutic setting. The authors report the case of a 39-year-old white man who suffered a simultaneous bilateral rupture while working out. When weightlifting with elbows at 90° of flexion, he suddenly felt pain on the anterior aspect of the arms, coming for evaluation after two days. He presented bulging contour of the biceps muscle belly and ecchymosis in the antecubital fossa, extending distally to the medial aspect of the forearm, as well as a marked decrease of supination strength and pain in active elbow flexion. MRI confirmed the rupture with retraction of the distal biceps bilaterally. The authors opted for performing the tendon repairs simultaneously through the double incision technique and fixation to the bicipital tuberosity with anchors. The patient progressed quite well, with full return to labor and sports activities, being satisfied with the result after two years of surgery. In the literature search, few reports of simultaneous bilateral rupture of the distal biceps were retrieved, with only one treated in the acute phase of injury. Therefore, the authors consider this procedure to be a good option to solve this complex condition.

  4. Simultaneous bilateral distal biceps tendon repair: case report.

    Science.gov (United States)

    Storti, Thiago Medeiros; Paniago, Alexandre Firmino; Faria, Rafael Salomon Silva

    2017-01-01

    Simultaneous bilateral rupture of the distal biceps tendon is a rare clinical entity, seldom reported in the literature and with unclear therapeutic setting. The authors report the case of a 39-year-old white man who suffered a simultaneous bilateral rupture while working out. When weightlifting with elbows at 90° of flexion, he suddenly felt pain on the anterior aspect of the arms, coming for evaluation after two days. He presented bulging contour of the biceps muscle belly and ecchymosis in the antecubital fossa, extending distally to the medial aspect of the forearm, as well as a marked decrease of supination strength and pain in active elbow flexion. MRI confirmed the rupture with retraction of the distal biceps bilaterally. The authors opted for performing the tendon repairs simultaneously through the double incision technique and fixation to the bicipital tuberosity with anchors. The patient progressed quite well, with full return to labor and sports activities, being satisfied with the result after two years of surgery. In the literature search, few reports of simultaneous bilateral rupture of the distal biceps were retrieved, with only one treated in the acute phase of injury. Therefore, the authors consider this procedure to be a good option to solve this complex condition.

  5. Evaluation of various filling techniques in distal canals of mandibular ...

    African Journals Online (AJOL)

    Evaluation of various filling techniques in distal canals of mandibular molars instrumented with different single-file nickel-titanium systems. ... Comparisons between groups were applied using Student's t-test or one-way ANOVA for normally distributed data. The Mann-Whitney U-test or Kruskal-Wallis test was used when ...

  6. A unique physeal injury of the distal phalanx.

    Science.gov (United States)

    Berber, Onur; Singh, Bijayendra

    2015-01-01

    An unusual Salter-Harris Type 1 fracture variant of the distal phalanx of the index finger is described. The epiphysis was dislocated, sitting dorsally over the middle phalanx head with the articular surface facing dorsal. Reduction could only be achieved through an open procedure. The reduction was stable without supplemental fixation.

  7. Unusual migration of ventriculo peritoneal distal catheter into vagina

    Directory of Open Access Journals (Sweden)

    Sghavamedin Tavallaee

    2015-04-01

    Full Text Available VP shunt is one of the most popular methods for ICP reduction and treatment of hydrocephalus. Various complications of this method are not uncommon such as shunt malfunction, infection and unusual migration of distal catheter. I present a case of migration of the peritoneal catheter out of the vagina.

  8. Laparoscopic versus open distal pancreatectomy for pancreatic cancer

    NARCIS (Netherlands)

    Riviere, D.M.; Gurusamy, K.S.; Kooby, D.A.; Vollmer, C.M.; Besselink, M.G.; Davidson, B.R.; Laarhoven, C.J.H.M. van

    2016-01-01

    BACKGROUND: Surgical resection is currently the only treatment with the potential for long-term survival and cure of pancreatic cancer. Surgical resection is provided as distal pancreatectomy for cancers of the body and tail of the pancreas. It can be performed by laparoscopic or open surgery. In

  9. Laparoscopic versus open distal pancreatectomy for pancreatic cancer

    NARCIS (Netherlands)

    Riviere, Deniece; Gurusamy, Kurinchi Selvan; Kooby, David A.; Vollmer, Charles M.; Besselink, Marc G. H.; Davidson, Brian R.; van Laarhoven, Cornelis J. H. M.

    2016-01-01

    Surgical resection is currently the only treatment with the potential for long-term survival and cure of pancreatic cancer. Surgical resection is provided as distal pancreatectomy for cancers of the body and tail of the pancreas. It can be performed by laparoscopic or open surgery. In operations on

  10. Autosomal dominant distal myopathy: Linkage to chromosome 14

    Energy Technology Data Exchange (ETDEWEB)

    Laing, N.G.; Laing, B.A.; Wilton, S.D.; Dorosz, S.; Mastaglia, F.L.; Kakulas, B.A. [Australian Neuromuscular Research Institute, Perth (Australia); Robbins, P.; Meredith, C.; Honeyman, K.; Kozman, H.

    1995-02-01

    We have studied a family segregating a form of autosomal dominant distal myopathy (MIM 160500) and containing nine living affected individuals. The myopathy in this family is closest in clinical phenotype to that first described by Gowers in 1902. A search for linkage was conducted using microsatellite, VNTR, and RFLP markers. In total, 92 markers on all 22 autosomes were run. Positive linkage was obtained with 14 of 15 markers tested on chromosome 14, with little indication of linkage elsewhere in the genome. Maximum two-point LOD scores of 2.60 at recombination fraction .00 were obtained for the markers MYH7 and D14S64 - the family structure precludes a two-point LOD score {ge} 3. Recombinations with D14S72 and D14S49 indicate that this distal myopathy locus, MPD1, should lie between these markers. A multipoint analysis assuming 100% penetrance and using the markers D14S72, D14S50, MYH7, D14S64, D14S54, and D14S49 gave a LOD score of exactly 3 at MYH7. Analysis at a penetrance of 80% gave a LOD score of 2.8 at this marker. This probable localization of a gene for distal myopathy, MPD1, on chromosome 14 should allow other investigators studying distal myopathy families to test this region for linkage in other types of the disease, to confirm linkage or to demonstrate the likely genetic heterogeneity. 24 refs., 3 figs., 1 tab.

  11. Detection of Lateglacial distal tephra layers in the Netherlands

    NARCIS (Netherlands)

    Davies, S.M.; Hoek, W.Z.; Bohncke, S.J.P.; Lowe, J.; Pyne O'Donnle, S.; Turney, C.S.M.

    2005-01-01

    Three distal tephra layers or cryptotephras have been detected within a sedimentary sequence from the Netherlands that spans the last glacial-interglacial transition. Geochemical analyses identify one as the Vedde Ash, which represents the southernmost discovery of this mid-Younger Dryas tephra so

  12. Outcome of management of distal radius fractures in ...

    African Journals Online (AJOL)

    Background and Purpose: Distal radial fractures are common fractures of postmenopausal age group patients. They are often called fractures of osteoporosis. These fractures are considered to be one of the commonest minor injuries to cause major morbidity in the community. A lot of patient who need surgery, fail to afford ...

  13. Snodgrass repair for distal hypospadias: a review of 75 cases

    African Journals Online (AJOL)

    urologists for distal hypospadias correction. We review our cases to find out whether there was any difference in the rate of urethrocutaneous fistula after the use of single- versus double-layer tubularization, the use of thick versus thin dorsal prepuce subcutaneous flap (DPF), the use of. DPF versus the ventral dartos flap for ...

  14. Spontaneous resolution of splenic infarcts after distal splenorenal ...

    African Journals Online (AJOL)

    Background: In cases of portal hypertension with splenic infarcts, splenectomy with proximal splenorenal shunt has been recommended. We are sharing our experience with distal splenorenal shunt in these cases contrary to the popular belief. Materials and Methods: Splenic infarcts were graded as mild, moderate and ...

  15. The distal shoe space maintainer chairside fabrication and clinical performance.

    Science.gov (United States)

    Brill, Warren A

    2002-01-01

    The chairside-fabricated distal shoe appliance, with a stainless steel crown as the retainer, is an efficacious and cost-effective appliance for guiding the unerupted permanent first molar into position after premature loss or extraction of the second primary molar. The fabrication technique is illustrated in this case report and data is presented on the success rate of the appliance.

  16. Eye Protection in Kansas Schools.

    Science.gov (United States)

    Hay, Kenneth M.; And Others

    A law passed by a state legislature requires that students in industrial arts shops and science laboratories must wear eye protective devices. Explanatory material presents the text of the bill and guidelines for implementation, including--(1) types of eye hazards, (2) types of protective devices, (3) administrating eye safety equipment, (4)…

  17. Reinforcing the role of the conventional C-arm - a novel method for simplified distal interlocking

    Directory of Open Access Journals (Sweden)

    Windolf Markus

    2012-01-01

    .018. Conclusions In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses.

  18. Reinforcing the role of the conventional C-arm--a novel method for simplified distal interlocking.

    Science.gov (United States)

    Windolf, Markus; Schroeder, Josh; Fliri, Ladina; Dicht, Benno; Liebergall, Meir; Richards, R Geoff

    2012-01-25

    shot to screw tightened) was on average 22% reduced by guided freehand (p = 0.018). In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses.

  19. Tritium removal and retention device

    International Nuclear Information System (INIS)

    Boyle, R.F.; Durigon, D.D.

    1980-01-01

    A device is provided for removing and retaining tritium from a gaseous medium, and also a method of manufacturing the device. The device, consists of an inner core of zirconium alloy, preferably Zircaloy-4, and an outer adherent layer of nickel which acts as a selective and protective window for passage of tritium. The tritium then reacts with or is absorbed by the zirconium alloy, and is retained until such time as it is desirable to remove it during reprocessing. (auth)

  20. Laparoscopic radical nephroureterectomy: dilemma of the distal ureter.

    Science.gov (United States)

    Steinberg, Jordan R; Matin, Surena F

    2004-03-01

    Laparoscopic nephroureterectomy has recently emerged as a safe, minimally invasive approach to upper tract urothelial cancers. The most controversial and challenging feature of laparoscopic nephroureterectomy is the management of the distal ureter. We review the most common methods of managing the distal ureter, with emphasis on contemporary oncologic outcomes, indications, advantages, and disadvantages. There are currently in excess of five different approaches to the lower ureter. These techniques often combine features of endoscopic, laparoscopic, or open management. They include open excision, a transvesical laparoscopic detachment and ligation technique, laparoscopic stapling of the distal ureter and bladder cuff, the "pluck" technique, and ureteral intussusception. Each technique has distinct advantages and disadvantages, differing not only in technical approach, but oncological principles as well. While the existing published data do not overwhelmingly support one approach over the others, the open approach remains one of the most reliable and oncologically sound procedures. The principles of surgical oncology dictate that a complete, en-bloc resection, with avoidance of tumor seeding, remains the preferred treatment of all urothelial cancers. The classical open technique of securing the distal ureter and bladder cuff achieves this principle and has withstood the test of time. Transvesical laparoscopic detachment and ligation is an oncologically valid approach in patients without bladder tumors, but is limited by technical considerations. The laparoscopic stapling technique maintains a closed system but risks leaving behind ureteral and bladder cuff segments. Both transurethral resection of the ureteral orifice (pluck) and intussusception techniques should be approached with caution, as the potential for tumor seeding exists. Additional long-term comparative outcomes are needed to solve the dilemma of the distal ureter.

  1. Distal pancreatectomy and splenectomy: a robotic or LESS approach.

    Science.gov (United States)

    Ryan, Carrie E; Ross, Sharona B; Sukharamwala, Prashant B; Sadowitz, Benjamin D; Wood, Thomas W; Rosemurgy, Alexander S

    2015-01-01

    The role and application of robotic surgery are debated, particularly given the expansion of laparoscopy, especially laparoendoscopic single-site (LESS) surgery. This cohort study was undertaken to delineate differences in outcomes between LESS and robotic distal pancreatectomy and splenectomy. With Institutional Review Board approval, patients undergoing LESS or robotic distal pancreatectomy and splenectomy from September 1, 2012, through December 31, 2014, were prospectively observed, and data were collected. The results are expressed as the median, with the mean ± SD. Thirty-four patients underwent a minimally invasive distal pancreatectomy and splenectomy: 18 with robotic and 16 with LESS surgery. The patients were similar in sex, age, and body mass index. Conversions to open surgery and estimated blood loss were similar. There were two intraoperative complications in the group that underwent the robotic approach. Time spent in the operating room was significantly longer with the robot (297 vs 254 minutes, P = .03), although operative duration (i.e., incision to closure) was not longer (225 vs 190 minutes; P = .15). Of the operations studied, 79% were undertaken for neoplastic processes. Tumor size was 3.5 cm for both approaches; R0 resections were achieved in all patients. Length of stay was similar in the two study groups (5 vs 4 days). There was one 30-day readmission after robotic surgery. Patient outcomes are similar with LESS or robotic distal pancreatectomy and splenectomy. Robotic operations require more time in the operating room. Both are safe and efficacious minimally invasive operations that follow similar oncologic principles for similar tumors, and both should be in the surgeon's armamentarium for distal pancreatectomy and splenectomy.

  2. Distal Oblique Bundle Reinforcement for Treatment of DRUJ Instability.

    Science.gov (United States)

    Brink, Peter R G; Hannemann, Pascal F W

    2015-08-01

    Background Chronic, dynamic bidirectional instability in the distal radioulnar joint (DRUJ) is diagnosed clinically, based on the patient's complaints and the finding of abnormal laxity in the vicinity of the distal ulna. In cases where malunion is ruled out or treated and there are no signs of osteoarthritis, stabilization of the DRUJ may offer relief. To this end, several different techniques have been investigated over the past 90 years. Materials and Methods In this article we outline the procedure for a new technique using a tendon graft to reinforce the distal edge of the interosseous membrane. Description of Technique A percutaneous technique is used to harvest the palmaris longus tendon and to create a tunnel, just proximal to the sigmoid notch, through the ulna and radius in an oblique direction. By overdrilling the radial cortex, the knotted tendon can be pulled through the radius and ulna and the knot blocked at the second radial cortex, creating a strong connection between the radius and ulna at the site of the distal oblique bundle (DOB). The tendon is fixed in the ulna with a small interference screw in full supination, preventing subluxation of the ulna out of the sigmoid notch during rotation. Results Fourteen patients were treated with this novel technique between 2011 and October 2013. The QuickDASH score at 25 months postoperatively (range 16-38 months) showed an improvement of 32 points. Similarly, an improvement of 33 points (67-34 months) was found on the PRWHE. Only one recurrence of chronic, dynamic bidirectional instability in the DRUJ was observed. Conclusion This simple percutaneous tenodesis technique between radius and ulna at the position of the distal edge of the interosseous membrane shows promise in terms of both restoring stability and relieving complaints related to chronic subluxation in the DRUJ.

  3. Information booklet on personal protective equipment: eye and face protection

    International Nuclear Information System (INIS)

    1992-01-01

    In all work places where hazards of various kinds are present and the same cannot be totally controlled by engineering methods, suitable personal protective equipment (PPE) shall be used. There are several types of eye and face protection devices available in the market and it is important that employees use the proper type for the particular job. The main classes of eye and face protection devices required for the industrial operations are as follows: (a) eye protection devices which includes: (i) safety goggles (ii) safety spectacles (iii) safety clipons and eye and face protection devices which are (i) eye shield, (ii) face shield, (iii) wire mesh screen guard. Guide lines for selecting appropriate ear and face protection equipment for nuclear installations are given. (M.K.V.). 4 annexures, 1 appendix

  4. Minimally invasive plating osteosynthesis for mid-distal third humeral shaft fractures.

    Science.gov (United States)

    Lian, Kejian; Wang, Lei; Lin, Dasheng; Chen, Zhiwen

    2013-08-01

    Mid-distal third humeral shaft fractures can be effectively treated with minimally invasive plating osteosynthesis and intramedullary nailing (IMN). However, these 2 treatments have not been adequately compared. Forty-seven patients (47 fractures) with mid-distal third humeral shaft fractures were randomly allocated to undergo either minimally invasive plating osteosynthesis (n=24) or IMN (n=23). The 2 groups were similar in terms of fracture patterns, fracture location, age, and associated injuries. Intraoperative measurements included blood loss and operative time. Clinical outcome measurements included fracture healing, radial nerve recovery, and elbow and shoulder discomfort. Radiographic measurements included fracture alignment, time to healing, delayed union, and nonunion. Functional outcome was satisfactory in both groups. Mean American Shoulder and Elbow Surgeons score and Mayo score were both better for the minimally invasive plating osteosynthesis group than for the IMN group (98.2 vs 97.6, respectively, and 93.5 vs 94.1, respectively; Pshaft fractures. Minimally invasive plating osteosynthesis is more suitable for complex fractures, especially for radial protection and motion recovery of adjacent joints, compared with IMN for simple fractures. Copyright 2013, SLACK Incorporated.

  5. Sealing device

    Science.gov (United States)

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  6. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  7. Gauging device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1979-01-01

    A gauge supporting device for measuring say a square tube comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a compression member or members. The tensioned guides provide planes of reference for measuring devices moved therealong on a carriage. The device is especially useful for making on site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (UK)

  8. A three-dimensional finite element analysis of molar distalization with a palatal plate, pendulum, and headgear according to molar eruption stage

    Science.gov (United States)

    Kang, Ju-Man; Park, Jae Hyun; Bayome, Mohamed; Oh, Moonbee; Park, Chong Ook; Mo, Sung-Seo

    2016-01-01

    Objective This study aimed to (1) evaluate the effects of maxillary second and third molar eruption status on the distalization of first molars with a modified palatal anchorage plate (MPAP), and (2) compare the results to the outcomes of the use of a pendulum and that of a headgear using three-dimensional finite element analysis. Methods Three eruption stages were established: an erupting second molar at the cervical one-third of the first molar root (Stage 1), a fully erupted second molar (Stage 2), and an erupting third molar at the cervical one-third of the second molar root (Stage 3). Retraction forces were applied via three anchorage appliance models: an MPAP with bracket and archwire, a bone-anchored pendulum appliance, and cervical-pull headgear. Results An MPAP showed greater root movement of the first molar than crown movement, and this was more noticeable in Stages 2 and 3. With the other devices, the first molar showed distal tipping. Transversely, the first molar had mesial-out rotation with headgear and mesial-in rotation with the other devices. Vertically, the first molar was intruded with an MPAP, and extruded with the other appliances. Conclusions The second molar eruption stage had an effect on molar distalization, but the third molar follicle had no effect. The application of an MPAP may be an effective treatment option for maxillary molar distalization. PMID:27668192

  9. Frequent complications and severe bone loss associated with the repiphysis expandable distal femoral prosthesis.

    Science.gov (United States)

    Cipriano, Cara A; Gruzinova, Irina S; Frank, Rachel M; Gitelis, Steven; Virkus, Walter W

    2015-03-01

    The treatment of choice for distal femur malignancies in skeletally immature patients remains controversial. An expandable endoprosthesis device (Repiphysis Limb Salvage System; Wright Medical Technology, Arlington, TN, USA) allows for limb preservation and noninvasive lengthening but has been associated with significant complications; however, the extent and implications of bone loss associated with this implant have not been reported. Our goals were to report (1) the 2-year minimum clinical outcomes after placement of the Repiphysis expandable prosthesis for pediatric distal femur malignancies; (2) the complications associated with this prosthesis; (3) the failure rate of this prosthesis; and (4) the revision alternatives available for salvage procedures. Between 2002 and 2010, one surgeon (SG) treated all skeletally immature patients (mean age, 10.1 years; range, 4.7-13.6 years) with distal femoral osteosarcoma using a Repiphysis expandable prosthesis. Of the 12 patients who met these criteria, two were excluded for death from disease before 2 years, and mean followup for the remaining 10 was 72 months (range, 26-119 months). Medical records were retrospectively reviewed for complications and clinical outcomes, as assessed by the Musculoskeletal Tumor Society (MSTS) scoring system. Radiographs at final followup were reviewed for bone loss and analyzed by the two senior authors (SG, WWV) to determine reconstruction options available for future revisions. MSTS scores averaged 67%, and we observed 37 implant-related complications requiring a total of 15 reoperations. Six patients underwent implant revisions with aseptic loosening being the predominant mode of failure; ultimately, four of these were converted to adult modular oncology prostheses, and two underwent total femoral replacements. Bone loss in this series was severe in terms of femoral length, cortical thinning, and metadiaphyseal compromise, and most patients will not have sufficient bone stock to permit

  10. Multicentre prospective evaluation of implant-assisted mandibular bilateral distal extension removable partial dentures: patient satisfaction

    NARCIS (Netherlands)

    Wismeijer, D.; Tawse-Smith, A.; Payne, A.G.T.

    2013-01-01

    Objective To compare the levels of patient satisfaction with either conventional mandibular bilateral distal extension partial dentures or those assisted by bilateral distal implants. Materials and methods Forty-eight participants who were dissatisfied with their existing conventional mandibular

  11. Minimally invasive versus open distal pancreatectomy (LEOPARD) : Study protocol for a randomized controlled trial

    NARCIS (Netherlands)

    de Rooij, Thijs; van Hilst, Jony; Vogel, Jantien A.; van Santvoort, Hjalmar C.; de Boer, Marieke T.; Boerma, Djamila; van den Boezem, Peter B.; Bonsing, Bert A.; Bosscha, Koop; Coene, Peter-Paul; Daams, Freek; van Dam, Ronald M.; Dijkgraaf, Marcel G.; van Eijck, Casper H.; Festen, Sebastiaan; Gerhards, Michael F.; Koerkamp, Bas Groot; Hagendoorn, Jeroen; van der Harst, Erwin; de Hingh, Ignace H.; Dejong, Cees H.; Kazemier, Geert; Klaase, Joost; de Kleine, Ruben H.; van Laarhoven, Cornelis J.; Lips, Daan J.; Luyer, Misha D.; Molenaar, I. Quintus; Nieuwenhuijs, Vincent B.; Patijn, Gijs A.; Roos, Daphne; Scheepers, Joris J.; van der Schelling, George P.; Steenvoorde, Pascal; Swijnenburg, Rutger-Jan; Wijsman, Jan H.; Abu Hilal, Moh'd; Busch, Olivier R.; Besselink, Marc G.

    2017-01-01

    Background: Observational cohort studies have suggested that minimally invasive distal pancreatectomy (MIDP) is associated with better short-term outcomes compared with open distal pancreatectomy (ODP), such as less intraoperative blood loss, lower morbidity, shorter length of hospital stay, and

  12. Multicenter comparative study of laparoscopic and open distal pancreatectomy using propensity score-matching.

    Science.gov (United States)

    Nakamura, Masafumi; Wakabayashi, Go; Miyasaka, Yoshihiro; Tanaka, Masao; Morikawa, Takanori; Unno, Michiaki; Tajima, Hiroshi; Kumamoto, Yusuke; Satoi, Sohei; Kwon, Masanori; Toyama, Hirochika; Ku, Yonson; Yoshitomi, Hideyuki; Nara, Satoshi; Shimada, Kazuaki; Yokoyama, Takahide; Miyagawa, Shinichi; Toyama, Yoichi; Yanaga, Katsuhiko; Fujii, Tsutomu; Kodera, Yasuhiro; Tomiyama, Yasuyuki; Miyata, Hiroaki; Takahara, Takeshi; Beppu, Toru; Yamaue, Hiroki; Miyazaki, Masaru; Takada, Tadahiro

    2015-10-01

    Laparoscopic distal pancreatectomy has been shown to be associated with favorable postoperative outcomes using meta-analysis. However, there have been no randomized controlled studies yet. This study aimed to compare laparoscopic and open distal pancreatectomy using propensity score-matching. We retrospectively collected perioperative data of 2,266 patients who underwent distal pancreatectomy in 69 institutes from 2006-2013 in Japan. Among them, 2,010 patients were enrolled in this study and divided into two groups, laparoscopic distal pancreatectomy and open distal pancreatectomy. Perioperative outcomes were compared between the groups using unmatched and propensity matched analysis. After propensity score-matching, laparoscopic distal pancreatectomy was associated with favorable perioperative outcomes compared with open distal pancreatectomy, including higher rate of preservation of spleen and splenic vessels (P pancreatectomy was associated with more favorable perioperative outcomes than open distal pancreatectomy. © 2015 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  13. Fusion devices

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1977-01-01

    Three types of thermonuclear fusion devices currently under development are reviewed for an electric utilities management audience. Overall design features of laser fusion, tokamak, and magnetic mirror type reactors are described and illustrated. Thrusts and trends in current research on these devices that promise to improve performance are briefly reviewed. Twenty photographs and drawings are included

  14. BRAKE DEVICE

    Science.gov (United States)

    O'Donnell, T.J.

    1959-03-10

    A brake device is described for utilization in connection with a control rod. The device comprises a pair of parallelogram link mechanisms, a control rod moveable rectilinearly therebetween in opposite directions, and shoes resiliently supported by the mechanism for frictional engagement with the control rod.

  15. Guide wire extension for shape memory polymer occlusion removal devices

    Science.gov (United States)

    Maitland, Duncan J [Pleasant Hill, CA; Small, IV, Ward; Hartman, Jonathan [Sacramento, CA

    2009-11-03

    A flexible extension for a shape memory polymer occlusion removal device. A shape memory polymer instrument is transported through a vessel via a catheter. A flexible elongated unit is operatively connected to the distal end of the shape memory polymer instrument to enhance maneuverability through tortuous paths en route to the occlusion.

  16. Single absorbable polydioxanone pin fixation for distal chevron bunion osteotomies.

    Science.gov (United States)

    Deorio, J K; Ware, A W

    2001-10-01

    The distal chevron osteotomy is a well-established technique for correction of symptomatic mild to moderate metatarsus primus varus with hallux valgus deformity. Fixation of the osteotomy ranges from none to bone pegs, Kirschner wires, screws, or absorbable pins. We evaluated one surgeon's (J.K.D.) results of distal chevron osteotomy fixation with a single, nonpredrilled, 1.3-mm poly-p-dioxanone pin and analyzed any differences in patients with unilateral or bilateral symptomatic metatarsus primus varus with hallux valgus deformities. All osteotomies healed without evidence of infection, osteolysis, nonunion, or necrosis. Equal correction was achieved in unilateral and bilateral procedures. The technique is quick and easy, and adequate fixation is achieved.

  17. Osteomyelitis Caused by Candida glabrata in the Distal Phalanx

    Directory of Open Access Journals (Sweden)

    Shunichi Toki

    2014-01-01

    Full Text Available Osteomyelitis caused by Candida glabrata is rare and its optimal treatment is unknown. Here we report a case of osteomyelitis caused by C. glabrata in the distal phalanx in a 54-year-old woman. Despite partial resection of the nail and administering a 1-month course of antibiotics for paronychia, the local swelling remained and an osteolytic lesion was found. C. glabrata osteomyelitis of the distal phalanx was later diagnosed after curettage. Thereafter, the patient was treated with antifungal agents for 3 months. The infection eventually resolved, and radiological healing of the osteolytic lesion was achieved. Antifungal susceptibility testing should be performed in the case of osteomyelitis caused by nonalbicans Candida species, due to their resistance to fluconazole.

  18. Retrograde nailing for distal femur fractures in the elderly

    Directory of Open Access Journals (Sweden)

    Giddie Jasdeep

    2015-01-01

    Full Text Available Introduction: We report the results of treating a series of 56 fractures in 54 elderly patients with a distal femur fracture with a retrograde femoral nail. Methods: Fifty-four of the nails were inserted percutaneously with a closed reduction. After surgery all patients were allowed to weight bear as tolerated. Four fractures were supported in a temporary external splint. Results: The mean age of patients was 80.6 years (range 51–103 years, 52/54 (96% were females. There were no cases of nail related complications and no re-operations were required. One patient was lost to follow up. The 30-day mortality was 5/54 (9.3% and the one year mortality was 17/54 (31.5%. Conclusions: Distal femoral nail fixation provides a good method of fixation allowing immediate mobilisation for this group of patients.

  19. Pendulum Therapy of Molar Distalization in Mixed Dentition.

    Science.gov (United States)

    Patil, Raju Umaji; Prakash, Amit; Agarwal, Anshu

    2016-01-01

    Early and timely pedo-orthodontic treatment is aimed at eliminating the disturbances of skeletal or dentoalveolar development, to harmonize the stomatognathic system before the full eruption of all permanent teeth. The advantages of pendulum appliance are its minimal dependence on patient's compliance (child cooperation), ease of fabrication, onetime activation and adjustment of the springs if necessary to correct minor transverse and vertical molar positions. This article reports a successful treatment method of class II malocclusion with pendulum appliance in mixed dentition phase. Distalization of maxillary molar was done, followed by guidance of canine impaction orthodontically and other dental correction using 0.022 MBT appliances. Posttreatment results were stable and remarkable. How to cite this article: Patil RU, Prakash A, Agarwal A. Pendulum Therapy of Molar Distalization in Mixed Dentition. Int J Clin Pediatr Dent 2016;9(1):67-73.

  20. Unravelling intention: distal intentions increase the subjective sense of agency.

    Science.gov (United States)

    Vinding, Mikkel C; Pedersen, Michael N; Overgaard, Morten

    2013-09-01

    Experimental studies investigating the contribution of conscious intention to the generation of a sense of agency for one's own actions tend to rely upon a narrow definition of intention. Often it is operationalized as the conscious sensation of wanting to move right before movement. Existing results and discussion are therefore missing crucial aspects of intentions, namely intention as the conscious sensation of wanting to move in advance of the movement. In the present experiment we used an intentional binding paradigm, in which we distinguished between immediate (proximal) intention, as usually investigated, and longer standing (distal) intention. The results showed that the binding effect was significantly enhanced for distal intentions compared to proximal intentions, indicating that the former leads to stronger sense of agency. Our finding provides empirical support for a crucial distinction between at least two types of intention when addressing the efficacy of conscious intentions. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Optimal fit of chairside-fabricated distal shoe space maintainer.

    Science.gov (United States)

    Nouri, M R; Kennedy, D B

    2013-10-01

    Premature loss of a primary second molar may lead to space loss in the dental arch. This space loss tends to be more severe in unfavourable malocclusions. The distal shoe space maintainer (DSSM) may be beneficial in controlling the path of eruption of an unerupted permanent first molar from the primary into the early mixed dentition. This article describes the technique for achieving optimal fit of a chairside-fabricated band and DSSM in a single visit by contouring the distal shoe blade, and by extending it to the mesial surface of the permanent first molar. Upon the eruption of the permanent first molar DSSM may be modified to a reverse band-and-loop, or replaced by a lingual holding arch.

  2. PLASMA DEVICE

    Science.gov (United States)

    Gow, J.D.; Wilcox, J.M.

    1961-12-26

    A device is designed for producing and confining highenergy plasma from which neutrons are generated in copious quantities. A rotating sheath of electrons is established in a radial electric field and axial magnetic field produced within the device. The electron sheath serves as a strong ionizing medium to gas introdueed thereto and also functions as an extremely effective heating mechanism to the resulting plasma. In addition, improved confinement of the plasma is obtained by ring magnetic mirror fields produced at the ends of the device. Such ring mirror fields are defined by the magnetic field lines at the ends of the device diverging radially outward from the axis of the device and thereafter converging at spatial annular surfaces disposed concentrically thereabout. (AFC)

  3. Fast-response protection from high currents

    International Nuclear Information System (INIS)

    Novikov, A.A.

    1989-01-01

    Protection devices for power electronic equipment from shorting current are described. The device is shunted using spark gaps with minimal possible number of spark gaps to protect it. High fast-response (<100 ns) and operation voltage wide range (6-100 kV) are attained using Arkadiev-Marx generator-base trigger devices and air-core pulse transformer

  4. The effect of distal utility value intervention for students’ learning

    OpenAIRE

    KERA, Masaki; NAKAYA, Motoyuki

    2017-01-01

    The purpose of this study was to determine whether a utility value intervention influenced students’motivation and performance. Specifically, we examined the effect of distal utility value (i.e., the recognition of content usefulness for skill development that can improve daily and future endeavors) instruction in this study.Fifty-one Japanese undergraduate students completed an experimental session in the laboratory, in which they performed a series of logical reasoning problem-solving tasks...

  5. Epidemiology of distal forearm fractures in Oslo, Norway.

    Science.gov (United States)

    Lofthus, C M; Frihagen, F; Meyer, H E; Nordsletten, L; Melhuus, K; Falch, J A

    2008-06-01

    The population of Oslo has the highest incidence of hip fracture reported. The present study shows that the overall incidence of distal forearm fractures in Oslo is higher than in other countries and has not changed significantly when comparing the incidence of 1998/99 with 1979. The population of Oslo has the highest incidence of hip fracture reported. The present study reports the incidence of distal forearm fracture in Oslo and the fracture rates of immigrants. Patients aged > or = 20 years resident in Oslo sustaining a distal forearm fracture in a one-year period in 1998/99 were identified using electronic diagnosis registers, patient protocols, and/or X-ray registers of the clinics in Oslo. Medical records were obtained and the diagnosis verified. The age- and sex-specific incidence rates were calculated and compared with those for 1979. Data on immigrant category and country of origin of the patients were obtained. The age-adjusted fracture rates per 10,000 for the age group > or = 50 years were 109.8 and 25.4 in 1998/99 compared with 108.3 and 23.5 in 1979 for women and men, respectively (n.s.). The relative risk of fracture in Asians was 0.72 (95% CI 0.53-1.00) compared with ethnic Norwegians. The overall incidence of distal forearm fractures in Oslo is higher than in other countries and has not changed significantly when comparing the incidence of 1998/99 with 1979. Furthermore, the present data suggest that Asian immigrants in Oslo have a slightly lower fracture risk than ethnic Norwegians.

  6. Dual-port distal gastrectomy for the early gastric cancer

    OpenAIRE

    Kashiwagi, Hiroyuki; Kumagai, Kenta; Monma, Eiji; Nozue, Mutsumi

    2014-01-01

    Background Although recent trends in laparoscopic procedures have been toward minimizing the number of incisions, four or five ports are normally required to complete laparoscopic gastrectomy because of the complexity of this procedure. Multi-channel ports, such as the SILS port (Covidien, JAPAN), are now available and are crucial for performing single-incision laparoscopic surgery (SILS) or reduced port surgery (RPS). We carried out reduced port distal gastrectomy (RPDG) using a dual-port me...

  7. Factors Associated with Infection Following Open Distal Radius Fractures

    OpenAIRE

    Glueck, Dane A.; Charoglu, Constantine P.; Lawton, Jeffrey N.

    2009-01-01

    Open fractures are often classified according to a system described by Gustilo and Anderson. However, this system was applied to open long bone factures, which may not predict the incidence of infection in open metaphyseal fractures of the upper extremity. Other studies have found that wound contamination and systemic illness were the best predictors of infections in open hand fractures. Our study assessed infection in open distal radius fractures and identifies factors that are associated wi...

  8. Is nonoperative management of partial distal biceps tears really successful?

    Science.gov (United States)

    Bauer, Tyler M; Wong, Justin C; Lazarus, Mark D

    2018-04-01

    The current treatment of partial distal biceps tears is a period of nonoperative management, followed by surgery, if symptoms persist. Little is known about the success rate and outcomes of nonoperative management of this illness. We identified 132 patients with partial distal biceps tears through an International Classification of Diseases, Ninth Revision code query of our institution's database. Patient records were reviewed to abstract demographic information and confirm partial tears of the distal biceps tendon based on clinical examination findings and confirmatory magnetic resonance imaging (MRI). Seventy-four patients completed an outcome survey. In our study, 55.7% of the contacted patients who tried a nonoperative course (34 of 61 patients) ultimately underwent surgery, and 13 patients underwent immediate surgery. High-need patients, as defined by occupation, were more likely to report that they recovered ideally if they underwent surgery, as compared with those who did not undergo surgery (odds ratio, 11.58; P = .0138). For low-need patients, the same analysis was not statistically significant (P = .139). There was no difference in satisfaction scores between patients who tried a nonoperative course before surgery and those who underwent immediate surgery (P = .854). An MRI-diagnosed tear of greater than 50% was a predictor of needing surgery (odds ratio, 3.0; P = .006). This study has identified clinically relevant information for the treatment of partial distal biceps tears, including the following: the failure rate of nonoperative treatment, the establishment of MRI percent tear as a predictor of failing nonoperative management, the benefit of surgery for the high-need occupational group, and the finding that nonoperative management does not negatively affect outcome if subsequent surgery is necessary. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  9. Characterisation of osseous bodies of the distal phalanx of foals

    International Nuclear Information System (INIS)

    Kaneps, A.J.; O'Brien, T.R.; Redden, R.F.; Stover, S.M.; Pool, R.R.

    1993-01-01

    The distal phalanx and metacarpal physis of both forelimbs of 32 Thoroughbred foals 3-32 weeks of age were radiographed to identify those limbs with osseous bodies at a palmar process (PP) of the distal phalanx. Osseous bodies (ossicles) were identified radiographically in 19% of the foals. Sixteen of the 32 foals were selected for microradiographic and histological evaluation: 6 foals with radiographic evidence of ossicles and 10 foals without. Fourteen ossicles of the PP were observed radiographically. Ossicles were either a triangular bone fragment at the palmar aspect of the distal angle of the PP, or an oblong bone fragment separated from P3 by a radiolucent line extending 1-3 cm from the incisure of the PP to the solar margin. One foal had radiographic evidence of bilateral distal metacarpal physitis. Seventeen of 35 PPs examined microradiographically were considered normal, in that the dorsal and solar cortices were thin with trabecular bone orientated parallel to the cortical surfaces, and there was a depression in the dorsal cortical surface (i.e. parietal sulcus). Abnormal microradiographic findings in the other 18 PPs included a fracture line extending from the dorsal cortical surfaces and trabecular bridging of the fracture gap. The fracture line was often continuous with the parietal sulcus. Microradiographic evidence of a fracture was found in 75% of foals evaluated. Normal histological findings in 16 PPs included thin dorsal and solar cortices with trabeculae orientated parallel to the cortical surfaces, parallel-fibred dense connective tissue attachments of the deep digital flexor tendon to the solar cortical surfaces, and a neurovascular bundle associated with the parietal sulcus

  10. External jig in the placement of distal interlocking screws | Ikem ...

    African Journals Online (AJOL)

    Retrograde (52.2%) was the commonest surgical approach used for femur. The main indication for SIGN interlocking surgery was recent fracture 77.8%. Open reduction 97.8% was the commonest method of reduction used. The mean±SD bone union time was 3.58±0.56 months and range 3-5 months. Distal screw insertion ...

  11. A PROSPECTIVE STUDY OF DISTAL TIBIAL FRACTURES BY MIPO (LCP)

    OpenAIRE

    Chandra Sekharam Naidu; Ch.Murali Krishna; Sankara Rao; Dharma Rao; Ashok Kumar

    2015-01-01

    INTRODUCTION: D istal tibial fractures represent a significant challenge to most of the surgeons even today. They constitute 1 - 10% of all lower extremity fractures . 1 The difficulty in treating the fractures of distal tibial end is exemplif ied by orthopedists, who in the first half of twentieth century, believed these injuries were so severe and fraught with so many complications, that these fractures wer...

  12. Distal renal tubular acidosis in recurrent renal stone formers

    DEFF Research Database (Denmark)

    Osther, P J; Hansen, A B; Røhl, H F

    1989-01-01

    Renal acidification ability was examined in 90 recurrent renal stone formers, using fasting morning urinary pH levels followed by a short ammonium chloride loading test in subjects with pH levels above 6.0. Fifteen patients (16.6%) revealed a distal renal tubular acidification defect: one patient......, this has important therapeutic implications. The pathological sequence in renal stone formers with dRTA is discussed....

  13. Impact of a Nationwide Training Program in Minimally Invasive Distal Pancreatectomy (LAELAPS)

    NARCIS (Netherlands)

    de Rooij, Thijs; van Hilst, Jony; Boerma, Djamila; Bonsing, Bert A.; Daams, Freek; van Dam, Ronald M.; Dijkgraaf, Marcel G.; van Eijck, Casper H.; Festen, Sebastiaan; Gerhards, Michael F.; Koerkamp, Bas Groot; van der Harst, Erwin; de Hingh, Ignace H.; Kazemier, Geert; Klaase, Joost; de Kleine, Ruben H.; van Laarhoven, Cornelis J.; Lips, Daan J.; Luyer, Misha D.; Molenaar, I. Quintus; Patijn, Gijs A.; Roos, Daphne; Scheepers, Joris J.; van der Schelling, George P.; Steenvoorde, Pascal; Vriens, Menno R.; Wijsman, Jan H.; Gouma, Dirk J.; Busch, Olivier R.; Hilal, Mohammed Abu; Besselink, Marc G.; de Boer, Marieke T.

    2016-01-01

    Objective:To study the feasibility and impact of a nationwide training program in minimally invasive distal pancreatectomy (MIDP).Summary of Background Data:Superior outcomes of MIDP compared with open distal pancreatectomy have been reported. In the Netherlands (2005 to 2013) only 10% of distal

  14. Cost-effectiveness of laparoscopic versus open distal pancreatectomy for pancreatic cancer

    NARCIS (Netherlands)

    Gurusamy, Kurinchi Selvan; Riviere, Deniece; van Laarhoven, C. J. H.; Besselink, Marc; Abu-Hilal, Mohammed; Davidson, Brian R.; Morris, Steve

    2017-01-01

    A recent Cochrane review compared laparoscopic versus open distal pancreatectomy for people with for cancers of the body and tail of the pancreas and found that laparoscopic distal pancreatectomy may reduce the length of hospital stay. We compared the cost-effectiveness of laparoscopic distal

  15. [Injury to the Scapholunate Ligament in Distal Radius Fractures: Peri-Operative Diagnosis and Treatment Results].

    Science.gov (United States)

    Gajdoš, R; Pilný, J; Pokorná, A

    2016-01-01

    PURPOSE OF THE STUDY Injury to the scapholunate ligament is frequently associated with a fracture of the distal radius. At present neither a unified concept of treatment nor a standard method of diagnosis in these concomitant injuries is available. The aim of the study was to evaluate a group of surgically treated patients with distal radius fractures in order to assess a contribution of combined conventional X-ray and intra-operative fluoroscopic examinations to the diagnosis of associated lesions and to compare short-term functional outcomes of sugically treated patients with those of patients treated conservatively. MATERIAL AND METHODS A group of patients undergoiong surgery for distal radius fractures using plate osteosynthesis was evaluated retrospectively. The peri-operative diagnosis of associated injury to the scapholunate ligament was based on pre-operative standard X-ray views and intra-operative fluoroscopy. The latter consisted of images of maximum radial and ulnar deviation as well as an image of the forearm in traction exerted manually along the long axis. All views were in postero-anterior projection. Results were read directly on the monitor of a fluoroscopic device after its calibration or were obtained by comparing the thickness of an attached Kirschner wire with the distance to be measured. Subsequently, pixels were converted to millimetres. When a scapholunate ligament injury was found and confirmed by examination of the contralateral wrist, the finding was verified by open reduction or arthroscopy. Both static and dynamic instabilities were treated together with the distal radius fracture at one-stage surgery. After surgery, the patients without ligament injury had the wrist immobilised for 4 weeks, then rehabilitation followed. In the patients with a damaged ligament, immobilisation in a short brace lasted until transarticular wires were removed. All patients were followed up for a year at least. At follow-up, the injured wrist was examined

  16. Computer tomographic assessment of postoperative peripancreatic collections after distal pancreatectomy.

    Science.gov (United States)

    Uchida, Yuichiro; Masui, Toshihiko; Sato, Asahi; Nagai, Kazuyuki; Anazawa, Takayuki; Takaori, Kyoichi; Uemoto, Shinji

    2018-03-27

    Peripancreatic collections occur frequently after distal pancreatectomy. However, the sequelae of peripancreatic collections vary from case to case, and their clinical impact is uncertain. In this study, the correlations between CT findings of peripancreatic collections and complications after distal pancreatectomy were investigated. Ninety-six consecutive patients who had undergone distal pancreatectomy between 2010 and 2015 were retrospectively investigated. The extent and heterogeneity of peripancreatic collections and background clinicopathological characteristics were analyzed. The extent of peripancreatic collections was calculated based on three-dimensional computed tomography images, and the degree of heterogeneity of peripancreatic collections was assessed based on the standard deviation of their density on computed tomography. Of 85 patients who underwent postoperative computed tomography imaging, a peripancreatic collection was detected in 77 (91%). Patients with either a large extent or a high degree of heterogeneity of peripancreatic collection had a significantly higher rate of clinically relevant pancreatic fistula than those without (odds ratio 5.95, 95% confidence interval 2.12-19.72, p = 0.001; odds ratio 8.0, 95% confidence interval 2.87-24.19, p = 0.0001, respectively). A large and heterogeneous peripancreatic collection was significantly associated with postoperative complications, especially clinically relevant postoperative pancreatic fistula. A small and homogenous peripancreatic collection could be safely observed.

  17. Total elbow arthroplasty for the treatment of distal humeral fractures.

    Science.gov (United States)

    Gallucci, G L; Larrondo Calderón, W; Boretto, J G; Castellaro Lantermo, J A; Terán, J; de Carli, P

    2016-01-01

    To report the clinical-functional outcomes of the treatment of humeral distal fractures with a total elbow prosthesis. This retrospective study was performed in two surgical centres. A total of 23patients were included, with a mean age of 79years, and of which 21 were women. The inclusion criteria were: patients with humeral distal fractures, operated on using a Coonrad-Morrey prosthesis, and with a follow-up of more than one year. According to AO classification, 15fractures were type C3, 7 C2 and 1 A2. All patients were operated on without de-insertion of the extensor mechanism. The mean follow-up was 40 months. Flexor-extension was 123-17°, with a total mobility arc of 106° (80% of the contralateral side). Pain, according to a visual analogue scale was 1. The Mayo Elbow Performance Index (MEPI) was 83 points. Excellent results were obtained in 8 patients, good in 13, medium in 1, and poor in 1. The mean DASH (disability) score was 24 points. Treatment of humeral distal fractures with total elbow arthroplasty could be a good treatment option, but indications must be limited to patients with complex fractures, poor bone quality, with osteoporosis and low functional demands. In younger patients, the use is limited to serious cases where there is no other treatment option. Level of Evidence IV. Copyright © 2016 SECOT. Published by Elsevier Espana. All rights reserved.

  18. Distal antebrachial fractures in toy-breed dogs

    International Nuclear Information System (INIS)

    Muir, P.

    1997-01-01

    Antebrachial fractures account for approximately 17% of all canine fractures, with motor vehicle trauma cited as one of the primary causes. However, antebrachial fractures in toy-breed dogs are often sustained after apparently minimal trauma, such as jumping or falling, and are usually distal. The cause of antebrachial fractures in toy breeds is not well understood. Complications after treatment of distal antebrachial fractures in toy-breed dogs, including delayed union, nonunion, and malunion, are common and are potentially serious because they may necessitate limb amputation. This article reports on distal antebrachial fractures in 26 toy-breed dogs that wee presented to the University of California, Davis, Veterinary Medical Teaching Hospital from April 1987 to March 1996. The author found that (1) these fractures typically occur in growing or adolescent dogs; (2) the presence of complications of union is typically associated with prior treatment using intramedullary pinning or external coaptation; and (3) successful healing of this type of fracture is obtained via rigid stabilization with bone plating in combination with cancellous bone autograft

  19. Suture anchor tenodesis in repair of distal Achilles tendon injuries.

    Science.gov (United States)

    Kiliçoğlu, Onder; Türker, Mehmet; Yildız, Fatih; Akalan, Ekin; Temelli, Yener

    2014-01-01

    Distal Achilles tendon avulsions are in the form of either bony and nonbony avulsion of Achilles tendon from its calcaneal insertion. Four patients with distal Achilles tendon avulsions or ruptures which were treated with tendon to bone repair using suture anchors are presented here. Operated leg was immobilized in above-knee cast for 4 weeks while the patient walked non-weight-bearing. Then, cast was changed to below knee, and full weight-bearing was allowed. Patients underwent gait analysis minimum at first postoperative year. Mean American Orthopedics Foot Ankle Society ankle/hindfoot score of patients at last visit was 88.75 (range 85-100), and Achilles tendon total rupture score was 77.75 (range 58-87). Mean passive dorsiflexion of injured ankles (14° ± 5°) was lower than uninjured ankles (23° ± 9°). All the kinematic parameters of gait analysis were comparable to the uninjured side. Maximum plantar flexion power of injured ankle was 1.40 W/kg, and this was significantly lower than the contralateral side value 2.38 W/kg; (P = 0.0143). There were no visually altered gait or problems in daily life. Suture anchor tenodesis technique of distal Achilles tendon avulsions was successful in achieving durable osteotendinous repairs.

  20. Laparoscopic distal pancreatectomy for adenocarcinoma of the pancreas

    Science.gov (United States)

    Björnsson, Bergthor; Sandström, Per

    2014-01-01

    Since the first report on laparoscopic distal pancreatectomy (LDP) appeared in the 1990s, the procedure has been performed increasingly frequently to treat both benign and malignant lesions of the pancreas. Many earlier publications have shown LDP to be a good alternative to open distal pancreatectomy for benign lesions, although this has never been studied in a prospective, randomized manner. The evidence for the use of LDP to treat adenocarcinoma of the pancreas is not as well established. The purpose of this review is to evaluate the current evidence for LDP in cases of pancreatic adenocarcinoma. We conducted a review of English language publications reporting LDP results between 1990 and 2013. All studies reporting results in patients with histologically proven pancreatic adenocarcinoma were included. Thirty-nine publications were found and included in the results for a total of 309 cases of pancreatic adenocarcinoma (potential double publications were not eliminated). Most LDP procedures are performed in selected cases and generally involve smaller tumors than open distal pancreatectomy (ODP) procedures. Some of the papers report unselected cases and include procedures on larger tumors. The number of lymph nodes harvested using LDP is comparable to the number obtained with ODP, as is the frequency of R0 resections. Current data suggest that similar short term oncological results can be obtained using LDP as those obtained using ODP. PMID:25309072

  1. Importance of early audiologic assessment in distal renal tubular acidosis

    Directory of Open Access Journals (Sweden)

    Elizabeth Norgett

    2010-12-01

    Full Text Available Anand P Swayamprakasam1, Elizabeth Stover1, Elizabeth Norgett1, Katherine G Blake-Palmer1, Michael J Cunningham2, Fiona E Karet11Department of Medical Genetics, Cambridge Institute for Medical Research, Cambridge, UK; 2Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston, MA, USAAbstract: Autosomal recessive distal renal tubular acidosis is usually a severe disease of childhood, often presenting as failure to thrive in infancy. It is often, but not always, accompanied by sensorineural hearing loss, the clinical severity and age of onset of which may be different from the other clinical features. Mutations in either ATP6V1B1 or ATP6V0A4 are the chief causes of primary distal renal tubular acidosis with or without hearing loss, although the loss is often milder in the latter. We describe a kindred with compound heterozygous alterations in ATP6V0A4, where hearing loss was formally diagnosed late in both siblings such that they missed early opportunities for hearing support. This kindred highlights the importance of routine audiologic assessments of all children with distal renal tubular acidosis, irrespective either of age at diagnosis or of which gene is mutated. In addition, when diagnostic genetic testing is undertaken, both genes should be screened irrespective of current hearing status. A strategy for this is outlined.Keywords: sensorineural hearing loss, renal tubular acidosis, recessive, genetics, mutation

  2. Ionotropic GABA Receptors and Distal Retinal ON and OFF Responses

    Directory of Open Access Journals (Sweden)

    E. Popova

    2014-01-01

    Full Text Available In the vertebrate retina, visual signals are segregated into parallel ON and OFF pathways, which provide information for light increments and decrements. The segregation is first evident at the level of the ON and OFF bipolar cells in distal retina. The activity of large populations of ON and OFF bipolar cells is reflected in the b- and d-waves of the diffuse electroretinogram (ERG. The role of gamma-aminobutyric acid (GABA, acting through ionotropic GABA receptors in shaping the ON and OFF responses in distal retina, is a matter of debate. This review summarized current knowledge about the types of the GABAergic neurons and ionotropic GABA receptors in the retina as well as the effects of GABA and specific GABAA and GABAC receptor antagonists on the activity of the ON and OFF bipolar cells in both nonmammalian and mammalian retina. Special emphasis is put on the effects on b- and d-waves of the ERG as a useful tool for assessment of the overall function of distal retinal ON and OFF channels. The role of GABAergic system in establishing the ON-OFF asymmetry concerning the time course and absolute and relative sensitivity of the ERG responses under different conditions of light adaptation in amphibian retina is also discussed.

  3. Three-stage treatment protocol for recalcitrant distal femoral nonunion.

    Science.gov (United States)

    Ma, Ching-Hou; Chiu, Yen-Chun; Tu, Yuan-Kun; Yen, Cheng-Yo; Wu, Chin-Hsien

    2017-04-01

    In this study, we proposed a three-stage treatment protocol for recalcitrant distal femoral nonunion and aimed to analyze the clinical results. We retrospective reviewed 12 consecutive patients with recalcitrant distal femoral nonunion undergoing our three-stage treatment protocol from January 2010 to December 2014 in our institute. The three-stage treatment protocol comprised debridement of the nonunion site, lengthening to eliminate leg length discrepancy, deformity correction, stabilization with a locked plate, filling of the defect with cement spacer for inducing membrane formation, and bone reconstruction using a cancellous bone autograft (Masquelet technique) or free vascularized fibular bone graft. The bone union time, wound complication, lower limbs alignment, amount of lengthening, knee range of motion, and functional outcomes were evaluated. Osseous union with angular deformity lengthening was 5.88 cm (range 3.5-12 cm). Excellent or good outcomes were obtained in 9 patients. Although the current study involved only a small number of patients and the intervention comprised three stages, we believe that such a protocol may be a valuable alternative for the treatment of recalcitrant distal femoral nonunion.

  4. Radiation protection measuring device SSM-1

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Product information from the producer on a universal measuring instrument for alpha, beta and gamma radiation designed for stationary and field use by military, police and fire brigades. 4 figs. (qui)

  5. Biomechanics of the Proximal Radius Following Drilling of the Bicipital Tuberosity to Mimic Cortical Button Distal Biceps Repair Technique.

    Science.gov (United States)

    Oak, Nikhil R; Lien, John R; Brunfeldt, Alexander; Lawton, Jeffrey N

    2018-05-01

    A fracture through the proximal radius is a theoretical concern after cortical button distal biceps fixation in an active patient. The permanent, nonossified cortical defect and medullary tunnel is at risk during a fall eliciting rotational and compressive forces. We hypothesized that during simulated torsion and compression, in comparison with unaltered specimens, the cortical button distal biceps repair model would have decreased torsional and compressive strength and would fracture in the vicinity of the bicipital tuberosity bone tunnel. Sixteen fourth-generation composite radius Sawbones models were used in this controlled laboratory study. A bone tunnel was created through the bicipital tuberosity to mimic the exact bone tunnel, 8 mm near cortex and 3.2 mm far cortex, made for the BicepsButton distal biceps tendon repair. The radius was then prepared and mounted on either a torsional or compression testing device and compared with undrilled control specimens. Compression tests resulted in average failure loads of 9015.2 N in controls versus 8253.25 N in drilled specimens ( P = .074). Torsional testing resulted in an average failure torque of 27.3 Nm in controls and 19.3 Nm in drilled specimens ( P = .024). Average fracture angle was 35.1° in controls versus 21.1° in drilled. Gross fracture patterns were similar in compression testing; however, in torsional testing all fractures occurred through the bone tunnel in the drilled group. There are weaknesses in the vicinity of the bone tunnel in the proximal radius during biomechanical stress testing which may not be clinically relevant in nature. In cortical button fixation, distal biceps repairs creates a permanent, nonossified cortical defect with tendon interposed in the bone tunnel, which can alter the biomechanical properties of the proximal radius during compressive and torsional loading.

  6. Risk of injury to the sural nerve during posterolateral approach to the distal tibia: An ultrasound simulation study.

    Science.gov (United States)

    Mizia, Ewa; Pękala, Przemysław A; Chomicki-Bindas, Piotr; Marchewka, Wojciech; Loukas, Marios; Zayachkowski, Alexander G; Tomaszewski, Krzysztof A

    2018-05-08

    Introduction When surgeons operate on the foot and ankle, the most common complication that may arise is injury of the cutaneous nerves. The sural nerve (SN) is potentially at risk of being injured when treating fractures involving the distal tibia using the posterolateral approach. The aim of this study was to evaluate how differences in length and position of the surgical treatment of fractures involving the distal tibia can affect the risk of SN injury. Materials and Methods The study involved 40 healthy volunteers (n=80 lower limbs). Ultrasound simulation of each potential surgical incision site was used to locate the SN and to assess the risk of injury. Results The study showed that the SN predominantly travels more posteriorly at levels more proximal from the tip of the lateral malleolus. At these more proximal points of the SN's course, it was proven that there was an overall increased incidence of iatrogenic injury to the SN in incisions made closer to the Achilles tendon. Based on these results, a quasi 3 dimensional figure was created showing the anatomical structures of this region to identify areas at high risk for SN injury. Conclusions By revealing how length and position of the surgical incision can influence the risk of SN injury, we hope to provide information to surgeons on the optimal technique to avoid iatrogenic SN injury while operating on the distal tibia via a posterolateral approach. This article is protected by copyright. All rights reserved. © 2018 Wiley Periodicals, Inc.

  7. [Results After Distal Digital Replantation - Is It Worth The Effort?

    Science.gov (United States)

    Braig, David; Thiele, Jan R; Penna, Vincenzo; Stark, G Björn; Eisenhardt, Steffen U

    2017-02-01

    There are only relative indications for distal digital replantation in zones 1 and 2 according to Tamai. In contrast to primary closure for fingertip amputations, replantation is a complex procedure that requires skills in supermicrosurgical techniques, as vessels with diameters between 0.3-0.8 mm are connected. In addition the time spent in hospital and the time off from work are longer. Distal digital replantation is thus only indicated, if the expected functional and aesthetic benefits surmount those of primary closure. We retrospectively analysed all fingertip amputations in zone 1 and 2 according to Tamai between 9/2009 and 7/2014 where we attempted distal digital replantation. The success of replantation, wound healing and functional results were evaluated according to Yamano. We performed 11 distal digital replantations in the study period. There were 6 total amputations, 4 subtotal amputations and 1 avulsion of the digital pulp. Revascularisation with long-term reattachment of the amputated tissues was possible in 8 cases (73%). In 3 cases (27%) secondary amputation closure was necessary. The mean operating time was 3 h 56 min. 6 patients, which had a successful replantation, were available for follow-up examinations after a mean period of 19 months. 5 patients were satisfied with the result and would again prefer replantation over primary amputation closure. 4 patients reported a good function of the replanted digits and did not complain about any limitations in their use. 2 patients complained about restricted function. All patients could return to their previous places of employment and were free of pain. Of the 12 affected digital nerves 11 nerves had a 2-point discrimination (2-PD) of ≤15 mm, 3 of them had a 2-PD between 7 and 10 mm and 4 of them of replanted digits and nail deformities in 2 patients. Distal digital replantation is complex and technically challenging. It leads to high patient satisfaction with only minimal functional

  8. The assessment of clinical distal symmetric polyneuropathy in type 1 diabetes: A comparison of methodologies from the Pittsburgh Epidemiology of Diabetes Complications Cohort

    OpenAIRE

    Pambianco, G.; Costacou, T.; Strotmeyer, Elsa; Orchard, T.J.

    2011-01-01

    Distal symmetrical polyneuropathy (DSP) is the most common type of diabetic neuropathy, but often difficult to diagnose reliably. We evaluated the cross-sectional association between three point-of-care devices, Vibratron II, NC-stat®, and Neurometer®, and two clinical protocols, MNSI and monofilament, in identifying those with DSP, and/or amputation/ulcer/neuropathic pain (AUP), the two outcomes of major concern. This report presents data from 195 type 1 diabetic participants of the Epidemio...

  9. 21 CFR 820.130 - Device packaging.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Device packaging. 820.130 Section 820.130 Food and... QUALITY SYSTEM REGULATION Labeling and Packaging Control § 820.130 Device packaging. Each manufacturer shall ensure that device packaging and shipping containers are designed and constructed to protect the...

  10. Anti-malware software and medical devices.

    Science.gov (United States)

    2010-10-01

    Just as much as healthcare information systems, medical devices need protection against cybersecurity threats. Anti-malware software can help safeguard the devices in your facility-but it has limitations and even risks. Find out what steps you can take to manage anti-malware applications in your devices.

  11. Instrument comprising a cable or tube provided provided with a propulsion device

    NARCIS (Netherlands)

    Breedveld, P.

    2006-01-01

    The invention relates to an instrument (1) comprising a cable or tube (3), at a distal end of which a propulsion device (4) is provided for moving the cable or tube in a hollow space, the propulsion device being shaped like a donut lying in a plane at right angles to the longitudinal direction of

  12. Sealing devices

    International Nuclear Information System (INIS)

    Coulson, R.A.

    1980-01-01

    A sealing device for minimising the leakage of toxic or radioactive contaminated environments through a biological shield along an opening through which a flexible component moves that penetrates the shield. The sealing device comprises an outer tubular member which extends over a length not less than the maximum longitudinal movement of the component along the opening. An inner sealing block is located intermediate the length of the component by connectors and is positioned in the bore of the outer tubular member to slide in the bore and effect a seal over the entire longitudinal movement of the component. The cross-section of the device may be circular and the block may be of polytetrafluoroethylene or of nylon impregnated with molybdenum or may be metallic. A number of the sealing devices may be combined into an assembly for a plurality of adjacent longitudinally movable components, each adapted to sustain a tensile load, providing the various drives of a master-slave manipulator. (author)

  13. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  14. Concave distal end of ulna metaphysis alone is not a sign of rickets

    Energy Technology Data Exchange (ETDEWEB)

    Oestreich, Alan E. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, 5031, Cincinnati, OH (United States)

    2015-07-15

    Statements have been made in the literature and in legal testimony that misrepresent the radiographic finding of concave distal end of the ulnar metaphysis. To demonstrate that a concave distal end of the ossified ulna in infancy can be normal. Eighty distal wrists of randomly selected infants in the first year of life with radiographic evidence that ruled out rickets were reviewed. In 16 of the cases (20%), mild or moderate concavity of the distal end of the ulna was seen. An intact metaphyseal collar of distal radius or ulna confirmed the absence of radiographic rickets. The finding of 20% of concave distal ulnas in the first year of life confirms the widely acknowledged statements that concave distal end of the ulna alone is not indicative of rickets. Statements to the contrary are not justified. (orig.)

  15. Concave distal end of ulna metaphysis alone is not a sign of rickets

    International Nuclear Information System (INIS)

    Oestreich, Alan E.

    2015-01-01

    Statements have been made in the literature and in legal testimony that misrepresent the radiographic finding of concave distal end of the ulnar metaphysis. To demonstrate that a concave distal end of the ossified ulna in infancy can be normal. Eighty distal wrists of randomly selected infants in the first year of life with radiographic evidence that ruled out rickets were reviewed. In 16 of the cases (20%), mild or moderate concavity of the distal end of the ulna was seen. An intact metaphyseal collar of distal radius or ulna confirmed the absence of radiographic rickets. The finding of 20% of concave distal ulnas in the first year of life confirms the widely acknowledged statements that concave distal end of the ulna alone is not indicative of rickets. Statements to the contrary are not justified. (orig.)

  16. 49 CFR 178.337-10 - Accident damage protection.

    Science.gov (United States)

    2010-10-01

    ... failure of the sacrificial device must leave the protected lading protection device and its attachment to the cargo tank wall intact and capable of retaining product. [Order 59-B, 30 FR 581, Jan. 16, 1965...

  17. [Effect factors analysis of knee function recovery after distal femoral fracture operation].

    Science.gov (United States)

    Bei, Chaoyong; Wang, Ruiying; Tang, Jicun; Li, Qiang

    2009-09-01

    To investigate the effect factors of knee function recovery after operation in distal femoral fractures. From January 2001 to May 2007, 92 cases of distal femoral fracture were treated. There were 50 males and 42 females, aged 20-77 years old (average 46.7 years old). Fracture was caused by traffic accident in 48 cases, by falling from height in 26 cases, by bruise in 12 cases and by tumble in 6 cases. According to Müller's Fracture classification, there were 29 cases of type A, 12 cases of type B and 51 cases of type C. According to American Society of Anesthesiologists (ASA) classification, there were 21 cases of grade I, 39 cases of grade II, 24 cases of grade III, and 8 cases of grade IV. The time from injury to operation was 4 hours to 24 days with an average of 7 days. Anatomical plate was used in 43 cases, retrograde interlocking intramedullary nail in 37 cases, and bone screws, bolts and internal fixation with Kirschner pins in 12 cases. After operation, the HSS knee function score was used to evaluate efficacy. Ten related factors were applied for statistical analysis, to knee function recovery after operation in distal femoral fractures, such as age, sex, preoperative ASA classification, injury to surgery time, fracture type, treatment, reduction quality, functional exercise after operation, whether or not CPM functional training and postoperative complications. Wound healed by first intention in 88 cases, infection occurred in 4 cases. All patients followed up 16-32 months with an average of 23.1 months. Clinical union of fracture was achieved within 3-7 months after operation. Extensor device adhesions and the scope of activities of fracture displacement in 6 cases, mild knee varus or valgus in 7 cases and implant loosening in 6 cases. According to HSS knee function score, the results were excellent in 52 cases, good in 15 cases, fair in 10 cases and poor in 15 cases with an excellent and good rate of 72.83%. Single factor analysis showed that age

  18. Factors associated with infection following open distal radius fractures.

    Science.gov (United States)

    Glueck, Dane A; Charoglu, Constantine P; Lawton, Jeffrey N

    2009-09-01

    Open fractures are often classified according to a system described by Gustilo and Anderson. However, this system was applied to open long bone fractures, which may not predict the incidence of infection in open metaphyseal fractures of the upper extremity. Other studies have found that wound contamination and systemic illness were the best predictors of infections in open hand fractures. Our study assessed infection in open distal radius fractures and identifies factors that are associated with these infections. We hypothesize that contamination, rather than absolute wound size, is the best predictor of infection associated with open distal radius fractures. A review by CPT code yielded 42 patients with open distal radius fractures between 1997 and 2002 treated at a level one trauma center. Medical records and radiographic follow-up were reviewed to assess the time to irrigation and debridement, the number of debridements in initial treatment period, the method of operative stabilization, the Gustilo and Anderson type of fracture, the Swanson type of fracture, and description of wound contamination. Forty-two patients were followed up for an average of 15 months (range 4 to 68 months). Twenty-four fractures were classified as Gustilo and Anderson type I, ten were type II, and eight were type III, 30 were Swanson type I, and 12 were Swanson type II. Five of the 42 fractures were considered contaminated. Two were exposed to fecal contamination. The others were contaminated with tar, dirt/grass, and gravel, respectively. Three of 42 (7%) fractures developed infections. All three infected cases received a single irrigation and debridement. Two of five contaminated fractures (40%) developed a polymicrobial infection. Both were exposed to fecal contamination and, therefore, considered Swanson type II fractures. They were classified as Gustilo and Anderson type II and IIIB based solely upon the size of the wound. Both required multiple debridements and eventually wrist

  19. Simple Device for Treating Prolapsing Loop Colostomy

    Directory of Open Access Journals (Sweden)

    Ming-Yu Hsieh

    2006-03-01

    Full Text Available Stoma prolapse is a common complication of intestinal stoma. Although various surgical methods yield satisfactory results, nonsurgical treatment may be better for a temporary stoma. We report a case of a patient with a distal limb prolapse of a right transverse colostomy who received nonsurgical treatment with satisfactory results. For the treatment of a temporary transverse loop colostomy with distal limb prolapse, we designed a simple device consisting of a pediatric plastic medicine cup, which was rolled into a towel to shape the bottom of the cup into a compressor. The towel was put on the stoma outside of the colostomy bag with the compressor above the prolapsing limb of the colostomy. An abdominal binder was applied to fix the towel.

  20. [Lithiasis of the distal ureter: ESWL or URS].

    Science.gov (United States)

    González Enguita, C; Sánchez Gómez, J; Rodríguez-Miñon Cifuentes, J L; Cabrera Pérez, J; Calahorra Fernández, F J; García Cardoso, J; García de la Peña, E; Vela Navarrete, R

    1998-10-01

    A nephritic colic is the clinical picture that evidences the presence of ureteral stones, the natural evolution being their spontaneous passing. Stones in the distal ureter are self-eliminated in about 71-80% cases. The adoption of a "watchful wait" involves an uncertain occupational and medical evolution since, although in some cases the stones will pass with no problems, in other instances they can result in severe, life threatening situations for the patient's health (intractable pain, anuria or sepsis). When a decision is made to treat the condition, there are two choices available: "in situ" SWEL (extracorporeal lithotrity), or URS (ureterorenoscopy), long-standing conflicting techniques each with its own advantages and disadvantages, which should now be considered complementary. SWEL's major disadvantage is the number of repetitions required and the long wait, sometimes even months, until the last fragment is passed. The greater strength of URS is that it can be resolutive in just one episode (95% cases), thus avoiding the obstruction problems that can arise after SWEL. In the Lithiasis-Lithotrity Unit of FJD, SWEL is the first therapeutical option for the treatment of stones in the distal ureter. SWEL and URS are equally likely to be performed although SWEL is the initial choice for efficiency reasons that are explained. We achieve 93.6% positive results with a 1.82% re-SWEL rate (retreatment), 0.60 coefficient of efficiency (EQ) and 0.69 modified coefficient of efficiency (EQM) (Chart). No serious complications were recorded. Morbidity is variable with little clinical significance. Distal ureter lithiasis can be treated with either URS and SWEL, both considered "different and complementary". The choice in each particular case and within each hospital will depend on availability of means to perform one or the other, equipment's efficiency, skill of the urologist, patient's preference and cost of each treatment.

  1. Clinicopathologic characteristics and prognosis of proximal and distal gastric cancer

    Directory of Open Access Journals (Sweden)

    Yu X

    2018-02-01

    Full Text Available Xuefeng Yu,1,* Fulan Hu,2,* Chunfeng Li,1 Qiang Yao,1 Hongfeng Zhang,1 Yingwei Xue1 1Department of Gastrointestinal Surgery, Harbin Medical University Cancer Hospital, Harbin Medical University, Harbin, China; 2Department of Epidemiology, Public Health College, Harbin Medical University, Harbin, China *These authors contributed equally to this work Background and objectives: The dismal prognosis of gastric cancer patients is a global problem. We aim to evaluate the clinicopathologic features and prognostic factors of proximal and distal gastric cancer.Materials and methods: Gastric cancer cases diagnosed and treated at the same surgical unit between 2007 and 2010 were reviewed. Follow-up data from all patients were collected for at least 5 years until 2015. A total of 964 patients were studied (distal gastric cancer [DG], n=777 and proximal gastric cancer [PG], n=187.Results: DG patients had a relatively higher percentage of females, more thorough therapy (R0 [D0/D1/D2], fewer combined organ resections, younger age, smaller tumors (<5 cm, shorter surgery durations, less blood loss during surgery, and a relatively lower percentage of nodal metastases and a TNM stage of 4 (p<0.05. A significantly higher 5-year survival rate was observed in DG patients compared to PG patients (DG: 51%, PG: 28%; p<0.001. A multivariate analysis demonstrated that tumor size, blood loss during surgery, surgery approach of lymph node dissection, treatment with palliative surgery, histopathologic type, TNM stage, and tumor location were independent predictors of poor outcome.Conclusion: The different characteristics and prognosis of DG and PG cases have implications for the development of guiding strategies for a surgical program and assessment of prognosis of gastric cancer patients based on tumor location. Keywords: gastric cancer, tumor location, clinicopathologic features, prognosis, distal gastric cancer, proximal gastric cancer 

  2. Outcome Assessment after Aptis Distal Radioulnar Joint (DRUJ Implant Arthroplasty

    Directory of Open Access Journals (Sweden)

    Amir Reza Kachooei

    2014-09-01

    Full Text Available Background:  Conventional treatments after complicated injuries of the distal radioulnar joint (DRUJ such as Darrach and Kapandji-Sauvé procedures have many drawbacks, which may eventually lead to a painful unstable distal ulna.  The development of DRUJ prosthesis has significantly evolved over the past years. In this study, we assessed the outcome results of patients after DRUJ implant arthroplasty using the Aptis (Scheker prosthesis. Methods: We identified 13 patients with 14 prosthesis during the past 10 years. Patients underwent DRUJ arthroplasty due to persistent symptoms of instability, chronic pain, and stiffness. Records and follow-up visits were reviewed to find the final post-operative symptoms, pain, range of motion, and grip strength with a mean follow-up of 12 months (range: 2-25 months. Also, patients were contacted prospectively by phone in order to  minister the disabilities of the armshoulder and hand (DASH, patient rated wrist evaluation (PRWE, and visual analogue scale (VAS, and to interview regarding satisfaction and progress in daily activities. Eleven patients out of 13 could be reached with a median followup time of 60 months (range: 2 to 102 months.  Results: No patient required removal of the prosthesis. Only two patients underwent secondary surgeries in which both required debridement of the screw tip over the radius. The median DASH score, PRWE score, VAS, and satisfaction were 1.3, 2.5, 0, and 10, respectively. The mean range of flexion, extension, supination, and pronation was 62, 54, 51, and 64, respectively. Conclusions: Distal radioulnar joint injuries are disabling and patients usually undergo one or more salvage surgeries prior to receiving an arthroplasty. The Scheker prosthesis has shown satisfactory results with 100% survival rate in all reports. The constrained design of this prosthesis gives enough stability to prevent painful subluxation.

  3. Medical expulsive treatment of distal ureteral stone using tamsulosin

    International Nuclear Information System (INIS)

    Ahmad, H.; Azim, W.; Akmal, M.; Murtaza, B.

    2015-01-01

    Many minimally invasive interventional techniques as well as expectant treatments exist for the management of lower ureteric calculi. This study was conducted to evaluate the efficacy of tamsulosin as an expulsive pharmacologic therapy for the treatment of distal ureteral stone. Methods: This randomized control trial included 100 patients over 18 years of age with stone Size = 8mm in distal 1/3 of ureter. Patients were randomly assigned into two groups (A and B). Group A Patients were given Capsule Tamsulosin 0.4 mg, 1 daily up to 4 weeks while group B patients were given placebo, 1 Capsule daily up to 4 weeks. The primary endpoint was expulsion rate. A written informed consent was taken from all the patients. Expulsion time, need for analgesics, need for hospitalization and drug side effects were secondary endpoints. Results: A total of 49 patients in group A and 48 patients in group B reported back, therefore 97 out of 100 patients were evaluated. Mean age of the patients was 36.34 years (range 18-57 years). Mean stone size was 5.78 mm (range 4-8 mm) in greatest dimension. A stone expulsion rate of 85.71% (42 patients) was noted in group A and 54.20% (26 patients) in group B. Group A revealed a statistically significant advantage in term of stone expulsion rate (p=0.032). Considering expulsion time in days group A showed statistically significant advantage (p=0.015). Regarding age, sex, stone size and stone lateralization (right/left), there was no significant difference between the group A and B. No drug side effects were noted in both the groups. Conclusion: By using tamsulosin a higher stone expulsion rates can be achieved in a shorter time. More randomized control trials are required to establish tamsulosin as a standard medical expulsive treatment for small distal ureteric calculus. (author)

  4. Prevention of distal extension cantilever fracture in mandibular overdentures.

    Science.gov (United States)

    Quirynen, Thomas; Quirynen, Marc; Duyck, Joke

    2015-09-01

    Fractures of distal bar extensions, supporting a mandibular overdenture, do occur with significant functional and economic consequences for the patient. This study therefore aims to evaluate the effect of different bar cross-sectional shapes and surfaces, bar extension lengths and the placement of a support rib under the distal bar extension on fracture resistance. The 2nd moment area and static strength were calculated for 11 frequently used bar designs using finite element analysis (FEA). For two specific designs (Ackermann round Ø 1.8mm and Dolder-Y macro, the former with and without a support rib) additional physical static and fatigue strength tests were included. The FEA static strength data corresponded well to the 2nd moment area (a similar ranking when maximum allowed force was considered). The application of a rib support (Ackermann Ø 1.8mm) and limitations of the bar extension length (6mm for the Ackermann Ø 1.8mm, 8mm for the Dolder-Y macro) allowed the bars to exceed 5 × 10(6) cycles of 120 and 250N, respectively, before fracture. The region of highest stresses in FEA corresponded well with the locations of the fractures observed in static- and fatigue-testing. With some simple guidelines/modifications, the number of bar extension fractures can be reduced significantly. This study focusses on distal bar extensions which improve the positioning of an implant supported overdenture. By combining laboratory testing and finite element simulations we aim to: (1) explain why fractures occur (dependent on physical characteristics of the bar), and (2) give clinical guidelines on how to prevent such fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Fractal analysis of bone architecture at distal radius

    International Nuclear Information System (INIS)

    Tomomitsu, Tatsushi; Mimura, Hiroaki; Murase, Kenya; Sone, Teruki; Fukunaga, Masao

    2005-01-01

    Bone strength depends on bone quality (architecture, turnover, damage accumulation, and mineralization) as well as bone mass. In this study, human bone architecture was analyzed using fractal image analysis, and the clinical relevance of this method was evaluated. The subjects were 12 healthy female controls and 16 female patients suspected of having osteoporosis (age range, 22-70 years; mean age, 49.1 years). High-resolution CT images of the distal radius were acquired and analyzed using a peripheral quantitative computed tomography (pQCT) system. On the same day, bone mineral densities of the lumbar spine (L-BMD), proximal femur (F-BMD), and distal radius (R-BMD) were measured by dual-energy X-ray absorptiometry (DXA). We examined the correlation between the fractal dimension and six bone mass indices. Subjects diagnosed with osteopenia or osteoporosis were divided into two groups (with and without vertebral fracture), and we compared measured values between these two groups. The fractal dimension correlated most closely with L-BMD (r=0.744). The coefficient of correlation between the fractal dimension and L-BMD was very similar to the coefficient of correlation between L-BMD and F-BMD (r=0.783) and the coefficient of correlation between L-BMD and R-BMD (r=0.742). The fractal dimension was the only measured value that differed significantly between both the osteopenic and the osteoporotic subjects with and without vertebral fracture. The present results suggest that the fractal dimension of the distal radius can be reliably used as a bone strength index that reflects bone architecture as well as bone mass. (author)

  6. Preventive Long-Term Effects of a Topical Film-Forming Medical Device with Ultra-High UV Protection Filters and DNA Repair Enzyme in Xeroderma Pigmentosum: A Retrospective Study of Eight Cases

    Directory of Open Access Journals (Sweden)

    Sandra Giustini

    2014-09-01

    Full Text Available Skin cancer is common in xeroderma pigmentosum (XP due to a DNA repair mechanisms genetic defect. Ultraviolet (UV exposure is the main cause of increased incidence of actinic keratosis (AK, basal cell carcinoma (BCC and squamous cell carcinoma (SCC observed in XP subjects. Photoprotection is therefore a mandatory strategy in order to reduce skin damage. A topical DNA repair enzyme has been shown to slow down the development of skin lesions in XP. However, there are no data regarding the effects of photoprotection combined with DNA repair strategies in this clinical setting. A film-forming medical device containing the DNA repair enzyme photolyase and very high-protection UV filters (Eryfotona AK-NMSC, Ery is currently available. We report retrospective data regarding the use of Ery in 8 patients (5 women, 3 men with a diagnosis of XP treated for at least 12 consecutive months, comparing the rate of new skin lesions (AK, BCC and SCC during active treatment with Ery and during 12 months just before the use of the product. New AK, BCC and SCC mean lesion numbers during the 1-year Ery treatment were 5, 3 and 0, respectively in comparison with 14, 6.8 and 3 lesions, respectively during the 1-year pre-treatment period. Ery use was associated with a 65% reduction in appearance of new AK lesions and with 56 and 100% reductions in the incidence of new BCC and SCC lesions, respectively. These data suggest that topical use of photoprotection and DNA repair enzyme could help lower skin cancer lesions in XP. Control prospective trials are advisable in this clinical setting.

  7. Lesiones de la sindesmosis tibioperonea distal: Review article

    OpenAIRE

    Álvarez López, Alejandro; Rodríguez Rodríguez, Eugenio; García Lorenzo, Yenima; Muñoz Infante, Arnaldo

    2008-01-01

    Se realizó una revisión bibliográfica sobre las lesiones traumáticas de la articulación tibioperonea distal. Se recuerda y actualiza sobre aspectos como: anatomía, mecanismo de producción y cuadro clínico. Reciben especial énfasis los estudios imagenológicos y se subraya el uso e interpretación de la radiografía simple. Para terminar esta revisión se exponen las variantes de tratamiento tanto para las lesiones ligamentosas aisladas o asociadas a fractura del tobillo y su manejo posoperatorio....

  8. Paediatric post-traumatic cortical defects of the distal radius

    International Nuclear Information System (INIS)

    Roach, Richard T.; Summers, Bruce N.; Cassar-Pullicino, Victor

    2002-01-01

    Paediatric post-traumatic cortical defects, although rare, are predominately seen affecting the distal radius following a greenstick or torus fracture. We review the literature and present a further two cases supported by CT and MRI. Images from an acute greenstick fracture are also presented to help understand the pathogenesis. Defects are typically solitary on plain radiographs and are usually noticed late, proximal to the site of compression. They are non-expansile in an otherwise healthy child. CT and MRI may reveal smaller multiple subperiosteal defects. Typical defects require no further management other than reassurance and advice that they may occasionally cause discomfort but resolve with time. (orig.)

  9. Proximal and distal adjustments of reaching behavior in preterm infants.

    Science.gov (United States)

    de Toledo, Aline Martins; Soares, Daniele de Almeida; Tudella, Eloisa

    2011-01-01

    The authors aimed to investigate proximal and distal adjustments of reaching behavior and grasping in 5-, 6-, and 7-month-old preterm infants. Nine low-risk preterm and 10 full-term infants participated. Both groups showed the predominance of unimanual reaching, an age-related increase in the frequency of vertical-oriented and open hand movement, and also an increase in successful grasping from 6 to 7 months. The frequency of open hand was higher in the preterm group at 6 months. Intrinsic restrictions imposed by prematurity did not seem to have impaired reaching performance of preterm infants throughout the months of age.

  10. Perimenopausal risk of falling and incidence of distal forearm fracture.

    OpenAIRE

    Winner, S. J.; Morgan, C. A.; Evans, J. G.

    1989-01-01

    A postal survey of 2000 women and 2000 men sampled from the electoral roll in Oxford was undertaken to ascertain whether changes with age in the risk of falling might explain the stepwise increases in age specific incidence rates of distal forearm fracture which occur in women at around the age of 50. Corrected response rates were 83% for women and 72% for men. In women, but not in men, there was a rise in the risk of falling from 45 years, peaking in the 55-59 year age group, and sinking to ...

  11. Giant cells tumor of radius distal end and bone reconstruction

    International Nuclear Information System (INIS)

    La O Duran, Eldis; Monzon Fernandez, Abel Nicolas; Sanz Delgado, Licett

    2009-01-01

    This is the case of a black women aged 40 presenting with a tumor of distal end of right radium with histological diagnosis of low-grade malignancy giant cells tumor and proposal of limb amputation. A conservative surgery was performed with a two-steps total exeresis of lesion sparing the oncologic margin. A fibular free-graft was used and wrist arthrodesis and internal fixation of graft using AO system. There was a good graft consolidation and an active incorporation of patient to social activities. The diagnosis, treatment, follow-up, rehabilitation and case prognosis are exposed

  12. Guide device

    International Nuclear Information System (INIS)

    Brammer, C.M. Jr.

    1977-01-01

    Disclosed is a fuel handling guide tube centering device for use in nuclear reactors during fuel assembly handling operations. The device comprises an outer ring secured to the flange of a nuclear reactor pressure vessel, a rotatable table rotatably coupled to the outer ring, and a plurality of openings through the table. Truncated locating cones are positioned in each of the openings in the table, and the locating cones center the guide tube during fuel handling operations. The openings in the table are located such that each fuel assembly in the nuclear core may be aligned with one of the openings by a suitable rotation of the table. The locating cones thereby provide alignment between the fuel handling mechanism located in the guide tube and the individual fuel assemblies of the cone. The need for a device to provide alignment is especially critical for floating nuclear power plants, where wave motion may exist during fuel handling operations. 5 claims, 4 figures

  13. RF and dc desensitized electroexplosive device

    Science.gov (United States)

    Krainiak, John W.; Speaks, Paul D.; Cornett, Michael S.

    1989-07-01

    This patent application relates to electroexplosive devices (EEDs) such as detonators, blasting caps and squibs, in particular to a method and device for desensitizing EEDs to electromagnetic radiation and electrostatic charges with the added ability to desensitize the device to essentially dc currents. An insensitive electroexplosive device to electrically ignite explosive is disclosed. This device is inherently immune to radio frequency (RF) radiation, and also provides protection against dc or very low frequency RF induced by arcing. A central feature is use of zeners and capacitors to form a reactively balanced bridge circuit. When constructed in semiconductor form, as described in this application, the device is capable of incorporation in small caliber ordnance.

  14. Cost-effectiveness of laparoscopic versus open distal pancreatectomy for pancreatic cancer.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Riviere, Deniece; van Laarhoven, C J H; Besselink, Marc; Abu-Hilal, Mohammed; Davidson, Brian R; Morris, Steve

    2017-01-01

    A recent Cochrane review compared laparoscopic versus open distal pancreatectomy for people with for cancers of the body and tail of the pancreas and found that laparoscopic distal pancreatectomy may reduce the length of hospital stay. We compared the cost-effectiveness of laparoscopic distal pancreatectomy versus open distal pancreatectomy for pancreatic cancer. Model based cost-utility analysis estimating mean costs and quality-adjusted life years (QALYs) per patient from the perspective of the UK National Health Service. A decision tree model was constructed using probabilities, outcomes and cost data from published sources. A time horizon of 5 years was used. One-way and probabilistic sensitivity analyses were undertaken. The probabilistic sensitivity analysis showed that the incremental net monetary benefit was positive (£3,708.58 (95% confidence intervals (CI) -£9,473.62 to £16,115.69) but the 95% CI includes zero, indicating that there is significant uncertainty about the cost-effectiveness of laparoscopic distal pancreatectomy versus open distal pancreatectomy. The probability laparoscopic distal pancreatectomy was cost-effective compared to open distal pancreatectomy for pancreatic cancer was between 70% and 80% at the willingness-to-pay thresholds generally used in England (£20,000 to £30,000 per QALY gained). Results were sensitive to the survival proportions and the operating time. There is considerable uncertainty about whether laparoscopic distal pancreatectomy is cost-effective compared to open distal pancreatectomy for pancreatic cancer in the NHS setting.

  15. Correction of Hallux Valgus Interphalangeus With an Osteotomy of the Distal End of the Proximal Phalanx (Distal Akin Osteotomy).

    Science.gov (United States)

    Vander Griend, Robert

    2017-02-01

    Operative correction of a symptomatic hallux valgus interphalangeus (HVI) deformity is often achieved with an osteotomy at the proximal end of the proximal phalanx (Akin osteotomy). However, the apex of the typical HVI deformity (center of rotation angle) is at the interphalangeal joint of the hallux. This study was done to evaluate the results of performing a medial closing wedge osteotomy at the distal end of the proximal phalanx. Thirty-three patients (33 feet) underwent an osteotomy at the distal end of the proximal phalanx for correction of HVI. All of the patients had other forefoot deformities which were corrected at the same time. Eight of these were revision procedures of prior forefoot operations. The length of follow-up was determined by the associated procedures with a minimum follow-up of 4 months. The preoperative hallux valgus interphalangeus angle averaged 16 degrees of valgus (range 7-32 degrees) and was corrected to an average of 2 degrees of valgus (range 5 degrees valgus to 5 degrees varus). All of the patients were satisfied with the postoperative appearance and function of the first toe. Because of simultaneous correction of numerous other forefoot problems, it was not possible to specifically isolate or evaluate the effects and benefits of this osteotomy using outcomes measures. There was one intraoperative complication resulting in a fracture extending into the adjacent IP joint. Correction of an HVI deformity can be achieved with an osteotomy at the distal end of the proximal phalanx. This was a safe technique with few complications and with good results in terms of both correction and patient satisfaction. Level IV, retrospective case series.

  16. Comparison of 3 Minimally Invasive Methods for Distal Tibia Fractures.

    Science.gov (United States)

    Fang, Jun-Hao; Wu, Yao-Sen; Guo, Xiao-Shan; Sun, Liao-Jun

    2016-07-01

    This study compared the results of external fixation combined with limited open reduction and internal fixation (EF + LORIF), minimally invasive percutaneous plate osteosynthesis (MIPPO), and intramedullary nailing (IMN) for distal tibia fractures. A total of 84 patients with distal tibia shaft fractures were randomized to operative stabilization using EF + LORIF (28 cases), MIPPO (28 cases), or IMN (28 cases). The 3 groups were comparable with respect to patient demographics. Data were collected on operative time and radiation time, union time, complications, time of recovery to work, secondary operations, and measured joint function using the American Orthopaedic Foot and Ankle Society (AOFAS) score. There was no significant difference in time to union, incidence of union status, time of recovery to work, and AOFAS scores among the 3 groups (P>.05). Mean operative time and radiation time in the MIPPO group were longer than those in the IMN or EF + LORIF groups (Pknee pain occurred frequently after IMN (32.1%), and irritation symptoms were encountered more frequently after MIPPO (46.4%). Although EF + LORIF was associated with fewer secondary procedures vs MIPPO or IMN, it was related with more pin-tract infections (14.3%). Findings indicated that EF + LORIF, MIPPO, and IMN all achieved similar good functional results. However, EF + LORIF had some advantages over MIPPO and IMN in reducing operative and radiation times, postoperative complications, and reoperation rate. [Orthopedics. 2016; 39(4):e627-e633.]. Copyright 2016, SLACK Incorporated.

  17. DIAGNOSTICS AND TREATMENT OF DISTAL RADIOULNAR JOINT INJURIES

    Directory of Open Access Journals (Sweden)

    A. V. Skoroglyadov

    2010-01-01

    Full Text Available We present the experience of treatment of 169 patients with distal radioulnar joint injuries, operated in specialized hand surgery department of the Clinic of traumatology and orthopedics of Russian State Medical University on the base of Moscow city clinical hospital № 4. We have carried out the following operations: closed osteoclasia of the distal epimetaphys fractures, osteotomy of the radius with the external fixator application in 97 (57,4% patients, percutaneous 2 Kirschner wires fixation of the ulna head to the radius after reposition of dislocation - 38 (22,5% patients, lavsanoplasty of DRUJ ligaments - 12 (7,1%, fixation of the ulna head to the radius by pin - 7 (4,1%, open reposition of dislocation of the ulna head and K-wire fixation - 8 (4,8%, osteotomy of synostosis of forearm bones, W. Darrach and Sauve-Kapandji operations - 7 (4,1%. Complications were observed in 13 (7,7% cases. Postponed results (1 year after operation were studied in 110 patients. We got good results in 95 (86,4% cases, satisfactory - in 12 (10,9% cases, unsatisfactory - in 3 (2,7% cases.

  18. Distraction lengthening of the proximal phalanx in distal thumb amputations.

    Science.gov (United States)

    Cansü, Eren; Ünal, Mehmet Bekir; Parmaksızoğlu, Fatih; Gürcan, Serkan

    2015-01-01

    Thumb amputation is a major cause of hand dysfunction, and the treatment for distal thumb amputations remains controversial. Although finger reconstruction methods using distraction lengthening are known to restore finger length and function, we found no reports in the literature regarding phalangeal lengthening in thumb amputations. We aimed to evaluate proximal phalangeal lengthening in thumb amputations at or near the interphalangeal (IP) joint. We retrospectively evaluated patients who had undergone distraction lengthening of the proximal phalanx of the thumb. All patients underwent osteotomy, either during the initial procedure or as a second-stage procedure. Distraction began 10 days after osteotomy with the use of an external fixator that remained in place until ossification of the gap occurred without bone grafting. Patients were evaluated using the QuickDASH score. Fourteen patients with a mean age of 27 years and a mean follow-up period of 7 years were enrolled. The mean phalangeal lengthening achieved was 20 mm. Ossification occurred at all distraction sites, and the fixators were maintained for a mean of 85 days. The mean healing index was 42.5 days/cm. All 14 patients achieved the desired amount of phalangeal lengthening without major complications such as nonunion, premature union, or gross infection. For reconstruction in cases of distal thumb amputations, distraction lengthening of the proximal phalanx can be used to improve absolute length, web space, and grip distance. The technique is safe and effective, improves functionality/cosmesis, and offers a low complication risk.

  19. Intramedullary Venous Drainage System for Distal Fingertip Replantations.

    Science.gov (United States)

    Purisa, Husrev; Ozturk, Muhammed Besir; Kabakas, Fatih; Mersa, Berkan; Ozcelik, Ismail Bulent; Sezer, Ilker

    2017-08-01

    The number of venous anastomoses performed during fingertip replantation is one of the most important factors affecting the success of replantation. However, because vessel diameters decrease in the zone 1 level, vessel anastomoses, especially vein anastomoses, are technically difficult and, thus, cannot be performed in most cases. Alternative venous drainage methods are crucial when any reliable vein repair is not possible. In the literature, so many artery-only replantation techniques have been defined, such as arteriovenous anastomoses, forming an arteriovenous or venocutaneous fistula, manual milking and massage, puncturing, and external bleeding via a fishmouth incision and using a medical leech. It has been shown that, in distal fingertip replantations, the medullary cavity may also be a good way for venous return. In this study, we introduce an alternative intramedullary venous drainage system we developed to facilitate venous drainage in artery-only fingertip replantations. The results of 24 fingertip replantations distal to the nail fold by using this system are presented with a literature review.

  20. Radiographic evaluation for AVN following distal metatarsal Stoffella bunion osteotomy.

    Science.gov (United States)

    Klein, Christian; Zembsch, Alexander; Dorn, Ulrich

    2009-01-01

    Avascular necrosis of the metatarsal head, delayed bone healing and nonunion are complications that may occur after distal first metatarsal osteotomies. Intraoperative damage to the extraosseous blood supply, the location of the osteotomy and postoperative vasospasm have been cited as possible causes of such changes. We evaluated Stoffella's subcapital osteotomies which were performed at our department for the correction of moderate to severe hallux valgus deformities. Standardized radiographs of 300 feet, taken 6weeks, 3 months, and 6 months postoperatively and at the final followup were examined with regard to postoperative AVN or signs of delayed bone healing. Of 228 patients, 202 were women and 26 were men. The patients' mean age was 49 years, and the mean followup was 12 months. In 278 cases the radiographs revealed an unremarkable first metatarsal head. Seventeen cases showed diffuse or localized osteopenia or small cysts in the subchondral bone. These changes fully resolved on subsequent radiographs. The X-rays of two patients revealed progressive narrowing of the joint space, irregular contours on the surface of the joint and an abnormal bone structure. The patients subsequently developed a characteristic picture of avascular necrosis, in one case combined with nonunion. Three patients had delayed bone healing, but ultimately healed successfully. Ischemic changes in bone are known to occur after distal first metatarsal osteotomies. There is a very low incidence of postoperative perfusion problems after Stoffella;s technique, even with lateral soft tissue release.

  1. DO PROXIMAL AND DISTAL GASTRIC TUMOURS BEHAVE DIFFERENTLY?

    Science.gov (United States)

    Costa, Laurence Bedin da; Toneto, Marcelo Garcia; Moreira, Luis Fernando

    2016-01-01

    Although the incidence of gastric (adenocarcinoma) cancer has been decreasing over time, it is still one of the most common malignancies worldwide, and proximal tumours tend to have a worse prognosis. To compare surgical outcomes and prognosis between proximal - excluding tumours of the cardia - and distal gastric cancer. Out of 293 cases reviewed - 209 with distal and 69 with proximal gastric cancer - were compared for clinical and pathological features, stage, surgical outcome, mortality and survival. Statistically, there was no significant difference between patients in both groups regarding mortality (p=0.661), adjuvant chemotherapy (p 0.661), and radiation (p=1.000). However, there was significant difference in the degree of lymph node dissection employed (p=0.002) and the number of positive lymph nodes resected (p=0.038) between the two groups. The odds of death at five years for patients who had a D0 dissection was three times greater (odds ratio 2.78; (95%CI 1.33-5.82) than that for patients who had a D2 dissection, while for patients who had a D1 dissection the odds ratio was only 1.41 (95%CI 0.71-2.83) compared to D2-dissected patients. Although no significant differences were found between proximal and distal gastric cancer, the increased risk of death in D0- and D1-dissected patients clearly suggests an important role of radical D2 lymph node dissection in survival. Embora a incidência do câncer gástrico esteja diminuindo nas últimas décadas, ele ainda aparece como uma das neoplasias malignas mais comuns, e tumores proximais tendem a ter pior prognóstico. Comparar os resultados cirúrgicos e o prognóstico entre o câncer gástrico proximal, excluindo os tumores da cárdia e junção esofagogástrica, e o distal. De 293 casos revistos - 209 distais e 69 proximais - foram comparados quanto aos achados clínicos e patológicos, estágio, resultados cirúrgicos, mortalidade e sobrevida. Estatisticamente não houve diferença entre pacientes em ambos

  2. Haptic device for telerobotic surgery

    Science.gov (United States)

    Salisbury, Curt; Salisbury, Jr., J. Kenneth

    2014-12-30

    A haptic device for telerobotic surgery, including a base; a linkage system having first and second linkage members coupled to the base; a motor that provides a motor force; a transmission including first and second driving pulleys arranged such that their faces form an angle and their axes form a plane, first and second idler pulleys offset from the plane and arranged between the first and second driving pulleys such that their axes divide the angle between the first and second driving pulleys, and a cable that traverses the first and second driving pulleys and the set of idler pulleys and transfers the motor force to the linkage system; an end effector coupled to distal ends of the first and second linkage members and maneuverable relative to the base; and a controller that modulates the motor force to simulate a body part at a point portion of the end effector.

  3. Medical Devices

    NARCIS (Netherlands)

    Verkerke, Gijsbertus Jacob; Mahieu, H.F.; Geertsema, A.A.; Hermann, I.F.; van Horn, J.R.; Hummel, J. Marjan; van Loon, J.P.; Mihaylov, D.; van der Plaats, A.; Schraffordt Koops, H.; Schutte, H.K.; Veth, R.P.H.; de Vries, M.P.; Rakhorst, G.; Shi, Donglu

    2004-01-01

    The development of new medical devices is a very time-consuming and costly process. Besides the time between the initial idea and the time that manufacturing and testing of prototypes takes place, the time needed for the development of production facilities, production of test series, marketing,

  4. Assistive Devices

    Science.gov (United States)

    If you have a disability or injury, you may use a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get ...

  5. Detection device

    Science.gov (United States)

    Smith, J.E.

    1981-02-27

    The present invention is directed to a detection device comprising: (1) an entrance chamber; (2) a central chamber; and (3) an exit chamber. The central chamber includes an ionizing gas, anode, and means for connecting the anode with an external power supply and pulse counter.

  6. Cooling device in thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Tsutomu.

    1988-01-01

    Purpose: To prevent loss of cooling effect over the entire torus structure directly after accidental toubles in a cooling device of a thermonuclear device. Constitution: Coolant recycling means of a cooling device comprises two systems, which are alternately connected with in-flow pipeways and exit pipeways of adjacent modules. The modules are cooled by way of the in-flow pipeways and the exist pipeways connected to the respective modules by means of the coolant recycling means corresponding to the respective modules. So long as one of the coolant recycling means is kept operative, since every one other modules of the torus structure is still kept cooled, the heat generated from the module put therebetween, for which the coolant recycling is interrupted, is removed by means of heat conduction or radiation from the module for which the cooling is kept continued. No back-up emergency cooling system is required and it can provide high economic reliability. (Kamimura, M.)

  7. Selecting the Protective Ear Plugs

    OpenAIRE

    Manouchehr Omidvari

    1999-01-01

    Exposure to noise is a one of the common problems in any industrial places. Many solutions have been introduced to overcome the deleterious effects of noise pollution maintaining and repairing systems in the equipments, environmental control and hearing conservation systems are some of these solutions that could be mentioned. "nThere are various types of Hearing protection devices and each one is useful under special circumstances. Commonly, different Hearing protection devices have a particu...

  8. Reactor power measuring device

    International Nuclear Information System (INIS)

    Izumi, Mikio; Sano, Yuji; Seki, Eiji; Yoshida, Toshifumi; Ito, Toshiaki.

    1993-01-01

    The present invention provides a self-powered long detector having a sensitivity over the entire length of a reactor core as an entire control rod withdrawal range of a BWR type reactor, and a reactor power measuring device using a gamma ray thermometer which scarcely causes sensitivity degradation. That is, a hollow protection pipe is disposed passing through the reactor core from the outside of a reactor pressure vessel. The self-powered long detectors and the gamma ray thermometers are inserted and installed in the protection pipe. An average reactor power in an axial direction of the reactor relative to a certain position in the horizontal cross section of the reactor core is determined based on the power of the self-powered long detector over the entire length of the reactor core. Since the response of the self-powered detector relative to a local power change is rapid, the output is used as an input signal to a safety protection device of the reactor core. Further, a gamma ray thermometer secured in the reactor and having scarce sensitivity degradation is used instead of an incore travelling neutron monitor used for relative calibration of an existent neutron monitor secured in the reactor. (I.S.)

  9. Renal denervation beyond the bifurcation: The effect of distal ablation placement on safety and blood pressure.

    Science.gov (United States)

    Beeftink, Martine M A; Spiering, Wilko; De Jong, Mark R; Doevendans, Pieter A; Blankestijn, Peter J; Elvan, Arif; Heeg, Jan-Evert; Bots, Michiel L; Voskuil, Michiel

    2017-04-01

    Renal denervation may be more effective if performed distal in the renal artery because of smaller distances between the lumen and perivascular nerves. The authors reviewed the angiographic results of 97 patients and compared blood pressure reduction in relation to the location of the denervation. No significant differences in blood pressure reduction or complications were found between patient groups divided according to their spatial distribution of the ablations (proximal to the bifurcation in both arteries, distal to the bifurcation in one artery and distal in the other artery, or distal to the bifurcation in both arteries), but systolic ambulatory blood pressure reduction was significantly related to the number of distal ablations. No differences in adverse events were observed. In conclusion, we found no reason to believe that renal denervation distal to the bifurcation poses additional risks over the currently advised approach of proximal denervation, but improved efficacy remains to be conclusively established. ©2017 Wiley Periodicals, Inc.

  10. Safety work with MRI devices in medicine

    International Nuclear Information System (INIS)

    Zivkovic, D.; Hrnjak, M.

    1999-01-01

    This paper gives the basis of biological effects of physical factors which could affect personnel working on MRI devices and patients, and corresponding protection measures. Medical personnel working with MRI devices and patients could be exposed to static magnetic field, time varying fields and radiofrequency radiation, danger from electric current and chemical matters, and there is a high risk from moving metal objects which could wound the persons near-by. The protection from static magnetic field could be ensured by increasing the distance from the source. If MRI device is put in Faradays cage it could be corresponding protection of radiofrequency radiation. (author)

  11. Health hazards of uranium dust from radioactive battlefields of the Balkan conflicts, Eastern Afghanistan and Iraq after the Gulf wars. Lessons for civil protection in the terrorist scenario of radiological dispersion devices

    International Nuclear Information System (INIS)

    Durakovic, A.; Klimaschewski, F.

    2007-01-01

    Complete text of publication follows. Purpose: The purpose of this study is to identify key health hazards of uranium dust from the radioactive battlefields (Balkan, Middle East and Eastern Afghanistan conflicts) to draw lessons for civil protection in the terrorist scenario of radiological dispersion devices (RDD). Gulf War I (GW I) in 1991 resulted in 350 metric tons of depleted uranium (DU) deposited in the environment and 3 to 6 million grams of DU aerosol dust particles released into the atmosphere, by the most conservative estimates. Its possible legacy (Gulf War disease) continues after the military conflicts (Operation Enduring Freedom, OEF, in Afghanistan and Gulf War II in Iraq). The symptoms of the multiorgan incapacitating progressive disease have been as numerous as their names, including incapacitating fatigue, musculoskeletal and joint pains, headaches, neuropsychiatric disorders, affects changes, confusion, visual problems, changes of gait, loss of memory, lympadenopathies, respiratory impairment, impotence, and urinary tract morphological and functional alterations. The disease is still a matter of controversy regarding etiology and pathogenesis of the syndrome commonly named Gulf War disease. It was underestimated and subsequently evolved in its clinical description through recognition of progressive symptomatology. Methods: UMRC's studies of the human contamination with uranium isotopes were conducted with the exposed subjects of Jalalabad, Spin Gar, Tora Bora, and Kabul areas in Afghanistan after OEF as well as Samawah, Baghdad and Basrah in Iraq after GW II. The urine samples of the subjects were analysed by the plasma mass spectrometry. The analytical methodology involved pre-concentration of the uranium using co-precipitation and/or evaporation, oxidation of organic matter, purification of uranium with ion exchange chromatography, and mass spectrometry with a double focusing Thermo-Elemental Plasma54 multi-collector ICP-MS equipped with a

  12. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients

    OpenAIRE

    Gupta, Rakesh K.; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2009-01-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-...

  13. Intersphincteric Resection and Coloanal Anastomosis in Treatment of Distal Rectal Cancer

    OpenAIRE

    Cipe, Gokhan; Muslumanoglu, Mahmut; Yardimci, Erkan; Memmi, Naim; Aysan, Erhan

    2012-01-01

    In the treatment of distal rectal cancer, abdominoperineal resection is traditionally performed. However, the recognition of shorter safe distal resection line, intersphincteric resection technique has given a chance of sphincter-saving surgery for patients with distal rectal cancer during last two decades and still is being performed as an alternative choice of abdominoperineal resection. The first aim of this study is to assess the morbidity, mortality, oncological, and functional outcomes ...

  14. Classification of Distal Fingertip Amputation Based on the Arterial System for Replantation

    OpenAIRE

    Park, Hyun Chul; Bahar-Moni, Ahmed Suparno; Cho, Sang Hyun; Kim, Sang Soo; Park, Hyun Sik; Ahn, Sang Cheon

    2012-01-01

    During replantation of distal fingertip amputation, identification of the artery is the most important but time consuming procedure. Depending on the damaged arterial structure, we classified distal fingertip amputations into 4 zones, on the basis of three dimensional concept. Zone 1 injury was defined as damage to the proximal central pulp artery; zone 2 injury, damage to the branch of the central pulp artery; zone 3 injury, damage to the distal central pulp artery; and zone 4 injury, no inj...

  15. Reliability of radiographic measurements for acute distal radius fractures

    International Nuclear Information System (INIS)

    Watson, Narelle J.; Asadollahi, Saeed; Parrish, Frank; Ridgway, Jacqueline; Tran, Phong; Keating, Jennifer L.

    2016-01-01

    The management of distal radial fractures is guided by the interpretation of radiographic findings. The aim of this investigation was to determine the intra- and inter-observer reliability of eight traditionally reported anatomic radiographic parameters in adults with an acute distal radius fracture. Five observers participated. All were routinely involved in making treatment decisions based on distal radius fracture radiographs. Observers performed independent repeated measurements on 30 radiographs for eight anatomical parameters: dorsal shift (mm), intra-articular gap (mm), intra-articular step (mm), palmar tilt (degrees), radial angle (degrees), radial height (mm), radial shift (mm), ulnar variance (mm). Intraclass correlation coefficients (ICCs) and the magnitude of retest errors were calculated. Measurement reliability was summarised as high (ICC > 0.80), moderate (0.60–0.80) or low (<0.60). Intra-observer reliability was high for dorsal shift and palmar tilt; moderate for radial angle, radial height, ulnar variance and radial shift; and low for intra-articular gap and step. Inter-observer reliability was high for palmar tilt; moderate for dorsal shift, ulnar variance, radial angle and radial height; and low for radial shift, intra-articular gap and step. Error magnitude (95 % confidence interval) was within 1–2 mm for intra-articular gap and step, 2–4 mm for ulnar variance, 4–6 mm for radial shift, dorsal shift and radial height, and 6–8° for radial angle and palmar tilt. Based on previous reports of critical values for palmar tilt, ulnar variance and radial angle, error margins appear small enough for measurements to be useful in guiding treatment decisions. Our findings indicate that clinicians cannot reliably measure values ≤1 mm for intra-articular gap and step when interpreting radiographic parameters using the standardised methods investigated in this study. As a guide for treatment selection, palmar tilt, ulnar variance and radial angle

  16. 46 CFR 111.51-3 - Protection of vital equipment.

    Science.gov (United States)

    2010-10-01

    ...-GENERAL REQUIREMENTS Coordination of Overcurrent Protective Devices § 111.51-3 Protection of vital equipment. (a) The coordination of overcurrent protective devices must be demonstrated for all potential... 46 Shipping 4 2010-10-01 2010-10-01 false Protection of vital equipment. 111.51-3 Section 111.51-3...

  17. Thin film device applications

    CERN Document Server

    Kaur, Inderjeet

    1983-01-01

    Two-dimensional materials created ab initio by the process of condensation of atoms, molecules, or ions, called thin films, have unique properties significantly different from the corresponding bulk materials as a result of their physical dimensions, geometry, nonequilibrium microstructure, and metallurgy. Further, these characteristic features of thin films can be drasti­ cally modified and tailored to obtain the desired and required physical characteristics. These features form the basis of development of a host of extraordinary active and passive thin film device applications in the last two decades. On the one extreme, these applications are in the submicron dimensions in such areas as very large scale integration (VLSI), Josephson junction quantum interference devices, magnetic bubbles, and integrated optics. On the other extreme, large-area thin films are being used as selective coatings for solar thermal conversion, solar cells for photovoltaic conver­ sion, and protection and passivating layers. Ind...

  18. Thermonuclear device

    International Nuclear Information System (INIS)

    Tezuka, Masaru.

    1993-01-01

    Protrusions and recesses are formed to a vacuum vessel and toroidal magnetic coils, and they are engaged. Since the vacuum vessel is generally supported firmly by a rack or the like by support legs, the toroidal magnetic field coils can be certainly supported against tumbling force. Then, there can be attained strong supports for the toroidal magnetic field coils, in addition to support by wedges on the side of inboard and support by share panels on the side of outboard, capable of withstanding great electromagnetic forces which may occur in large-scaled next-generation devices. That is, toroidal magnetic field coils excellent from a view point of deformation and stress can be obtained, to provide a thermonuclear device of higher reliability. (N.H.)

  19. Thermonuclear device

    International Nuclear Information System (INIS)

    Oosaki, Osamu; Masuda, Kenju.

    1980-01-01

    Purpose: To provide excellent electric properties and high reliability in a thermonuclear device by improving a current collecting board connected to a coil device. Constitution: A current collecting board element perforated with an opening for enserting a connecting terminal is sized to be inserted into a plating tank, and is surface treated in the plating tank. Only the current collecting board element preferably surface treated is picked up. A plurality of such current collecting board elements are connected and welded to form a large current collecting board. In this manner, the current collecting board having several m 2 to several ten order m 2 in area can be obtained as preferably surface treated at the connecting terminal hole. The current collecting board element can be determined in shape with the existing facility without increasing the size of a surface treating tank. (Kamimura, M.)

  20. Thermonuclear device

    International Nuclear Information System (INIS)

    Yagi, Yasuomi; Takahashi, Ken; Hashimoto, Hiroshi.

    1984-01-01

    Purpose: To improve the plasma confining performances by bringing the irregular magnetic fields nearly to zero and decreasing the absolute value of the irregular magnetic fields at every positions. Constitution: The winding direction of a plurality of coil elements, for instance, double pan cake coils of toroidal coils in a torus type or mirror type thermonuclear device are reversed to each other in their laminating direction, whereby the irregular magnetic fields due to the coil-stepped portions in each toroidal coils are brought nearly to zero. This enables to bring the average irregular magnetic fields as a whole in the thermonuclear device nearly to zero, as well as, decrease the absolute value of the irregular magnetic fields in each positions. Thus, the plasma confining performances can be improved. (Moriyama, K.)