WorldWideScience

Sample records for displays stronger dependence

  1. Spectral intensity dependence an isotropy of sources stronger than 0.1 Jy at 2700 MHz

    International Nuclear Information System (INIS)

    Balonek, T.J.; Broderick, J.J.; Condon, J.J.; Crawford, D.F.; Jauncey, D.L.

    1975-01-01

    The 1000-foot (305 m) telescope of the National Astronomy and Ionosphere Center was used to measure 430 MHz flux densities of sources stronger than 0.1 Jy at 2700 MHz. Distributions of the resulting two-point spectral indices α (430, 2700) of sources in the intensity range 0.1less than or equal toS<0.35 Jy were compared with α (318, 2700) distributions of sources stronger than 0.35 Jy at 2700 MHz. The median normal-component spectral index and fraction of flat-spectrum sources in the faintest sample do not continue the previously discovered trend toward increased spectral steepening of faint sources. This result differs from the prediction of simple evolutionary cosmological models and therefore favors the alternative explanation that local source-density inhomogeneities are responsible for the observed intensity dependence of spectral indices

  2. Visual ergonomic aspects of glare on computer displays: glossy screens and angular dependence

    Science.gov (United States)

    Brunnström, Kjell; Andrén, Börje; Konstantinides, Zacharias; Nordström, Lukas

    2007-02-01

    Recently flat panel computer displays and notebook computer are designed with a so called glare panel i.e. highly glossy screens, have emerged on the market. The shiny look of the display appeals to the costumers, also there are arguments that the contrast, colour saturation etc improves by using a glare panel. LCD displays suffer often from angular dependent picture quality. This has been even more pronounced by the introduction of Prism Light Guide plates into displays for notebook computers. The TCO label is the leading labelling system for computer displays. Currently about 50% of all computer displays on the market are certified according to the TCO requirements. The requirements are periodically updated to keep up with the technical development and the latest research in e.g. visual ergonomics. The gloss level of the screen and the angular dependence has recently been investigated by conducting user studies. A study of the effect of highly glossy screens compared to matt screens has been performed. The results show a slight advantage for the glossy screen when no disturbing reflexes are present, however the difference was not statistically significant. When disturbing reflexes are present the advantage is changed into a larger disadvantage and this difference is statistically significant. Another study of angular dependence has also been performed. The results indicates a linear relationship between the picture quality and the centre luminance of the screen.

  3. Switching speeds in NCAP displays: dependence on collection angle and wavelength

    Science.gov (United States)

    Reamey, Robert H.; Montoya, Wayne; Wartenberg, Mark

    1991-06-01

    The on and off switching speeds of nematic droplet-polymer films (NCAP) are shown to depend on the collection angle (f/#) and the wavelength of the light used in the measurement. Conventional twisted nematic liquid crystal displays have switching speeds which depend little on these factors. The switching speed dependence on collection angle (f/#) and wavelength for nematic droplet-polymer films is inherent to the mechanism by which light is modulated in these films. This mechanism is the scattering of light by the nematic droplets. The on times become faster and the off times become slower as the collection angle of detection is increased. The overall change in switching speed can be large. Greater than 100X changes in off time have been observed. As the wavelength of the light used to interrogate the sample is increased (blue yields green yields red) the on times become faster and the off times become slower. This dependence of switching speed on wavelength is apparent at all collection angles. An awareness of these effects is necessary when developing nematic droplet-polymer films for display applications and when comparing switching speed data from different sources.

  4. Density regulation in Northeast Atlantic fish populations: Density dependence is stronger in recruitment than in somatic growth.

    Science.gov (United States)

    Zimmermann, Fabian; Ricard, Daniel; Heino, Mikko

    2018-05-01

    Population regulation is a central concept in ecology, yet in many cases its presence and the underlying mechanisms are difficult to demonstrate. The current paradigm maintains that marine fish populations are predominantly regulated by density-dependent recruitment. While it is known that density-dependent somatic growth can be present too, its general importance remains unknown and most practical applications neglect it. This study aimed to close this gap by for the first time quantifying and comparing density dependence in growth and recruitment over a large set of fish populations. We fitted density-dependent models to time-series data on population size, recruitment and age-specific weight from commercially exploited fish populations in the Northeast Atlantic Ocean and the Baltic Sea. Data were standardized to enable a direct comparison within and among populations, and estimated parameters were used to quantify the impact of density regulation on population biomass. Statistically significant density dependence in recruitment was detected in a large proportion of populations (70%), whereas for density dependence in somatic growth the prevalence of density dependence depended heavily on the method (26% and 69%). Despite age-dependent variability, the density dependence in recruitment was consistently stronger among age groups and between alternative approaches that use weight-at-age or weight increments to assess growth. Estimates of density-dependent reduction in biomass underlined these results: 97% of populations with statistically significant parameters for growth and recruitment showed a larger impact of density-dependent recruitment on population biomass. The results reaffirm the importance of density-dependent recruitment in marine fishes, yet they also show that density dependence in somatic growth is not uncommon. Furthermore, the results are important from an applied perspective because density dependence in somatic growth affects productivity and

  5. Photon energy dependence and angular response of glass display used in mobile phones for accident dosimetry

    International Nuclear Information System (INIS)

    Discher, Michael; Greiter, Matthias; Woda, Clemens

    2014-01-01

    Previous studies have shown that glass displays extracted from mobile phones are suitable as emergency dosimeters in case of an accidental radiation overexposure using the thermoluminescence (TL) method. So far these studies have focused only on recovering the absorbed dose to the material. However, dose in air or dose to the victim carrying the device might be significantly different. Therefore the aim of this work was to investigate photon energy dependence and angular response of glass display used in modern mobile phones. An over-response of about a factor of five is observed for low photon energies compared to the response to Cs-137 (662 keV) which is in reasonable agreement with calculated values mass energy-absorption coefficients of glass and air. Little variation in the energy dependence can be seen for glass displays coming from three different mobile phone models. The angular response for display glass is flat with regard to air kerma within the incident angle of ±60°, independent of the irradiation setup used (with a water phantom or with air kerma reference conditions). For incident angles of 90° the shielding effect of the mobile phones becomes important. With the dosimetric characterization of the photon energy and angular dependencies the absorbed dose in a glass display can be transferred to a reference air kerma dose and provides a useful option for retrospective accident dosimetry. - Highlights: • Determination of the photon energy dependence and angular response for display glass used as an accident dosimeter. • Over-response of about a factor of five for low photon energies. • Flat angular response within incident angles between ±60°

  6. Content dependent selection of image enhancement parameters for mobile displays

    Science.gov (United States)

    Lee, Yoon-Gyoo; Kang, Yoo-Jin; Kim, Han-Eol; Kim, Ka-Hee; Kim, Choon-Woo

    2011-01-01

    Mobile devices such as cellular phones and portable multimedia player with capability of playing terrestrial digital multimedia broadcasting (T-DMB) contents have been introduced into consumer market. In this paper, content dependent image quality enhancement method for sharpness and colorfulness and noise reduction is presented to improve perceived image quality on mobile displays. Human visual experiments are performed to analyze viewers' preference. Relationship between the objective measures and the optimal values of image control parameters are modeled by simple lookup tables based on the results of human visual experiments. Content dependent values of image control parameters are determined based on the calculated measures and predetermined lookup tables. Experimental results indicate that dynamic selection of image control parameters yields better image quality.

  7. A configural dominant account of contextual cueing: Configural cues are stronger than colour cues.

    Science.gov (United States)

    Kunar, Melina A; John, Rebecca; Sweetman, Hollie

    2014-01-01

    Previous work has shown that reaction times to find a target in displays that have been repeated are faster than those for displays that have never been seen before. This learning effect, termed "contextual cueing" (CC), has been shown using contexts such as the configuration of the distractors in the display and the background colour. However, it is not clear how these two contexts interact to facilitate search. We investigated this here by comparing the strengths of these two cues when they appeared together. In Experiment 1, participants searched for a target that was cued by both colour and distractor configural cues, compared with when the target was only predicted by configural information. The results showed that the addition of a colour cue did not increase contextual cueing. In Experiment 2, participants searched for a target that was cued by both colour and distractor configuration compared with when the target was only cued by colour. The results showed that adding a predictive configural cue led to a stronger CC benefit. Experiments 3 and 4 tested the disruptive effects of removing either a learned colour cue or a learned configural cue and whether there was cue competition when colour and configural cues were presented together. Removing the configural cue was more disruptive to CC than removing colour, and configural learning was shown to overshadow the learning of colour cues. The data support a configural dominant account of CC, where configural cues act as the stronger cue in comparison to colour when they are presented together.

  8. Color dependence with horizontal-viewing angle and colorimetric characterization of two displays using different backlighting

    Science.gov (United States)

    Castro, José J.; Pozo, Antonio M.; Rubiño, Manuel

    2013-11-01

    In this work we studied the color dependence with a horizontal-viewing angle and colorimetric characterization of two liquid-crystal displays (LCD) using two different backlighting: Cold Cathode Fluorescent Lamps (CCFLs) and light-emitting diodes (LEDs). The LCDs studied had identical resolution, size, and technology (TFT - thin film transistor). The colorimetric measurements were made with the spectroradiometer SpectraScan PR-650 following the procedure recommended in the European guideline EN 61747-6. For each display, we measured at the centre of the screen the chromaticity coordinates at horizontal viewing angles of 0, 20, 40, 60 and 80 degrees for the achromatic (A), red (R), green (G) and blue (B) channels. Results showed a greater color-gamut area for the display with LED backlight, compared with the CCFL backlight, showing a greater range of colors perceptible by human vision. This color-gamut area diminished with viewing angle for both displays. Higher differences between trends for viewing angles were observed in the LED-backlight, especially for the R- and G-channels, demonstrating a higher variability of the chromaticity coordinates with viewing angle. The best additivity was reached by the LED-backlight display (a lower error percentage). LED-backlight display provided better color performance of visualization.

  9. Searing sentiment or cold calculation? the effects of leader emotional displays on team performance depend on follower epistemic motivation

    NARCIS (Netherlands)

    van Kleef, G.A.; Homan, A.C.; Beersma, B.; van Knippenberg, D.; van Knippenberg, B.; Damen, F.

    2009-01-01

    We examined how leader emotional displays affect team performance. We developed and tested the idea that effects of leader displays of anger versus happiness depend on followers' epistemic motivation, which is the desire to develop a thorough understanding of a situation. Experimental data on

  10. Energy-dependent imaging in digital radiography: a review on acquisition, processing and display technique

    International Nuclear Information System (INIS)

    Coppini, G.; Maltinti, G.; Valli, G.; Baroni, M.; Buchignan, M.; Valli, G.

    1986-01-01

    The capabilities of energy-dependent imaging in digital radiography are analyzed paying particular attention to digital video systems. The main techniques developed in recent years for selective energy imaging are reviewed following a unified approach. Discussion about advantages and limits of energy methods is carried out by a comparative analysis of computer simulated data and experimental results as obtained by standard x-ray equipments coupled to a digital video unit. Geometric phantoms are used as test object, as also images of a chest phantom are produced. Since signal-to-noise ratio degradation is one of the major problems when dealing with selective imaging, a particular effort is made to investigate noise effects. In this perspective, an original colour encoding display of energy sequences is presented. By mapping the various energy measurements on different colour bands (typically those of an RGB TV-monitor), an increased image conspicuity is obtained without a significant noise degradation: this is ensured by the energy dependence of attenuation coefficients and by the integrating characteristics of the display device

  11. Stronger Schrödinger-like uncertainty relations

    International Nuclear Information System (INIS)

    Song, Qiu-Cheng; Qiao, Cong-Feng

    2016-01-01

    Highlights: • A stronger Schrödinger-like uncertainty relation in the sum of variances of two observables is obtained. • An improved Schrödinger-like uncertainty relation in the product of variances of two observables is obtained. • A stronger uncertainty relation in the sum of variances of three observables is proposed. - Abstract: Uncertainty relation is one of the fundamental building blocks of quantum theory. Nevertheless, the traditional uncertainty relations do not fully capture the concept of incompatible observables. Here we present a stronger Schrödinger-like uncertainty relation, which is stronger than the relation recently derived by Maccone and Pati (2014) [11]. Furthermore, we give an additive uncertainty relation which holds for three incompatible observables, which is stronger than the relation newly obtained by Kechrimparis and Weigert (2014) [12] and the simple extension of the Schrödinger uncertainty relation.

  12. Female Psychology in August Strindberg's the Stronger

    OpenAIRE

    Sutandio, Anton; Apriliani, Erica

    2017-01-01

    This research aimed to offer interpretations of August Strindberg's The Stronger through the lens of female psychology. The Stronger is unique as it seemed very simple yet so intense and powerful with layers of interpretations. Written during 1888-1889, The Stronger, which only had two characters and only one speaking character, had become one of Strindberg's shortest yet important plays during his career. The female psychology approach used in the analysis would cover the discussion of gende...

  13. Stronger Fire-Resistant Epoxies

    Science.gov (United States)

    Fohlen, George M.; Parker, John A.; Kumar, Devendra

    1988-01-01

    New curing agent improves mechanical properties and works at lower temperature. Use of aminophenoxycyclotriphosphazene curing agents yields stronger, more heat- and fire-resistant epoxy resins. Used with solvent if necessary for coating fabrics or casting films.

  14. Book Display as Adult Service

    Directory of Open Access Journals (Sweden)

    Matthew S. Moore

    1997-03-01

    Full Text Available 無Book display as an adult service is defined as choosing and positioning adult books from the collection to increase their circulation. The author contrasts bookstore arrangement for sales versus library arrangement for access. The paper considers the library-as-a-whole as a display, examines the right size for an in-library display, and discusses mass displays, end-caps, on-shelf displays, and the Tiffany approach. The author proposes that an effective display depends on an imaginative, unifying theme, and that book displays are part of the joy of libraries.

  15. Prospects for stronger calandria tubes

    International Nuclear Information System (INIS)

    Ells, C.E.; Coleman, C.E.; Hosbons, R.R.; Ibrahim, E.F.; Doubt, G.L.

    1990-12-01

    The CANDU calandria tubes, made of seam welded and annealed Zircaloy-2, have given exemplary service in-reactor. Although not designed as a system pressure containment, calandria tubes may remain intact even in the face of pressure tube rupture. One such incident at Pickering Unit 2 demonstrated the economic advantage of such an outcome, and a case can be made for increasing the probability that other calandria tubes would perform in a similar fashion. Various methods of obtaining stronger calandria tubes are available, and reviewed here. When the tubes are internally pressurized, the weld is the weak section of the tube. Increasing the oxygen concentration in the starting sheet, and thickening the weld, are promising routes to a stronger tube

  16. Performance of NCAP projection displays

    Science.gov (United States)

    Jones, Philip J.; Tomita, Akira; Wartenberg, Mark

    1991-08-01

    Prototypes of projection displays based on dispersions of liquid crystal in polymer matrices are beginning to appear. The principle of operation depends on electrically switchable light scattering. They are potentially much brighter than current cathode ray tube (CRT) or twisted nematic liquid crystal (TN LC) cell based displays. Comparisons of efficacy and efficiency show this. The contrast and brightness of such displays depend on a combination of the f- number of the projection system and the scattering characteristics of the light valve. Simplified equations can be derived to show these effects. The degree of scattering of current NCAP formulations is sufficient to produce good contrast projection displays, at convenient voltages, that are around three times brighter than TN LC projectors because of the lack of polarizers in the former.

  17. Female Psychology in August Strindberg’s The Stronger

    Directory of Open Access Journals (Sweden)

    Anton Sutandio

    2017-11-01

    Full Text Available This research aimed to offer interpretations of August Strindberg’s The Stronger through the lens of female psychology. The Stronger is unique as it seemed very simple yet so intense and powerful with layers of interpretations. Written during 1888-1889, The Stronger, which only had two characters and only one speaking character, had become one of Strindberg’s shortest yet important plays during his career. The female psychology approach used in the analysis would cover the discussion of gender role, women’s self-esteem, competition for males, women’s friendships, ego style, and female psychology. It was an interdisciplinary research that combined structuralist, historical, biographical, and feminist approach to gain a better interpretation on the play. By referring to three different sources on the concept of female psychology, the analysis offered different and interesting interpretations on the nature and dynamics of the two female characters’ relationship. The Stronger has shown an enigmatic attraction in Strindberg’s authorship in which the readers could see the co-existence, collision, conflict, and merge of different paradigms concerning sex, gender, and sexuality.

  18. The Educational Program "Zajedno Jaci" (Stronger Together) in Croatia

    Science.gov (United States)

    Spanja, Sanja

    2011-01-01

    In this paper, we explore intercultural learning undertaken through the educational program "Stronger Together." The program "Stronger Together" was created in 1998 in order to support and educate teachers working with children in post-war regions of Croatia using intercultural education and cooperative learning as tools for…

  19. Stronger synergies

    CERN Multimedia

    Antonella Del Rosso

    2012-01-01

    CERN was founded 58 years ago under the auspices of UNESCO. Since then, both organisations have grown to become world leaders in their respective fields. The links between the two have always existed but today they are even stronger, with new projects under way to develop a more efficient way of exchanging information and devise a common strategy on topics of mutual interest.   CERN and UNESCO are a perfect example of natural partners: their common field is science and education is one of the pillars on which both are built. Historically, they share a common heritage. Both UNESCO and CERN were born of the desire to use scientific cooperation to rebuild peace and security in the aftermath of the Second World War. "Recently, building on our common roots and in close collaboration with UNESCO, we have been developing more structured links to ensure the continuity of the actions taken over the years," says Maurizio Bona, who is in charge of CERN relations with international orga...

  20. Temporal Dependency and the Structure of Early Looking.

    Science.gov (United States)

    Messinger, Daniel S; Mattson, Whitney I; Todd, James Torrence; Gangi, Devon N; Myers, Nicholas D; Bahrick, Lorraine E

    2017-01-01

    Although looking time is used to assess infant perceptual and cognitive processing, little is known about the temporal structure of infant looking. To shed light on this temporal structure, 127 three-month-olds were assessed in an infant-controlled habituation procedure and presented with a pre-recorded display of a woman addressing the infant using infant-directed speech. Previous individual look durations positively predicted subsequent look durations over a six look window, suggesting a temporal dependency between successive infant looks. The previous look duration continued to predict the subsequent look duration after accounting for habituation-linked declines in look duration, and when looks were separated by an inter-trial interval in which no stimulus was displayed. Individual differences in temporal dependency, the strength of associations between consecutive look durations, are distinct from individual differences in mean infant look duration. Nevertheless, infants with stronger temporal dependency had briefer mean look durations, a potential index of stimulus processing. Temporal dependency was evident not only between individual infant looks but between the durations of successive habituation trials (total looking within a trial). Finally, temporal dependency was evident in associations between the last look at the habituation stimulus and the first look at a novel test stimulus. Thus temporal dependency was evident across multiple timescales (individual looks and trials comprised of multiple individual looks) and persisted across conditions including brief periods of no stimulus presentation and changes from a familiar to novel stimulus. Associations between consecutive look durations over multiple timescales and stimuli suggest a temporal structure of infant attention that has been largely ignored in previous work on infant looking.

  1. Stronger multilayer acrylic dielectric elastomer actuators with silicone gel coatings

    Science.gov (United States)

    Lau, Gih-Keong; La, Thanh-Giang; Sheng-Wei Foong, Ervin; Shrestha, Milan

    2016-12-01

    Multilayer dielectric elastomer actuators (DEA) perform worst off than single-layer DEAs due to higher susceptibility to electro-thermal breakdown. This paper presents a hot-spot model to predict the electro-thermal breakdown field of DEAs and its dependence on thermal insulation. To inhibit the electrothermal breakdown, silicone gel coating was applied as barrier coating to multilayer acrylic DEA. The gel coating helps suppress the electro-thermally induced puncturing of DEA membrane at the hot spot. As a result, the gel-coated DEAs, in either a single layer or a multilayer stack, can produce 30% more isometric stress change as compared to those none-coated. These gel-coated acrylic DEAs show great potential to make stronger artificial muscles.

  2. Crosstalk in concurrent repeated games impedes direct reciprocity and requires stronger levels of forgiveness.

    Science.gov (United States)

    Reiter, Johannes G; Hilbe, Christian; Rand, David G; Chatterjee, Krishnendu; Nowak, Martin A

    2018-02-07

    Direct reciprocity is a mechanism for cooperation among humans. Many of our daily interactions are repeated. We interact repeatedly with our family, friends, colleagues, members of the local and even global community. In the theory of repeated games, it is a tacit assumption that the various games that a person plays simultaneously have no effect on each other. Here we introduce a general framework that allows us to analyze "crosstalk" between a player's concurrent games. In the presence of crosstalk, the action a person experiences in one game can alter the person's decision in another. We find that crosstalk impedes the maintenance of cooperation and requires stronger levels of forgiveness. The magnitude of the effect depends on the population structure. In more densely connected social groups, crosstalk has a stronger effect. A harsh retaliator, such as Tit-for-Tat, is unable to counteract crosstalk. The crosstalk framework provides a unified interpretation of direct and upstream reciprocity in the context of repeated games.

  3. Children's Control/Display Stereotypes.

    Science.gov (United States)

    Hoffmann, Errol R; Chan, Alan H S; Tai, Judy P C

    2018-06-01

    Objective The aim of this study was to determine control/display stereotypes for children of a range of ages and development of these stereotypes with age. Background Little is known about control/display stereotypes for children of different ages and the way in which these stereotypes develop with age. This study is part of a program to determine the need to design differentially for these age groups. Method We tested four groups of children with various tasks (age groups 5 to 7, 8 to 10, 11 to 13, 14 to 16), with about 30 in each group. Examples of common tasks were opening a bottle, turning on taps, and allocating numbers to keypads. More complex tasks involved rotating a control to move a display in a requested direction. Results Tasks with which different age groups were familiar showed no effect of age group. Different control/display arrangements generally showed an increase in stereotype strength with age, with dependence on the form of the control/display arrangement. Two-dimensional arrangements, with the control on the same plane as the display, had higher stereotype strength than three-dimensional arrangements for all age groups, suggesting an effect of familiarity with controls and displays with increasing age. Conclusion Children's control/display stereotypes do not differ greatly from those of adults, and hence, design for children older than 5 years of age, for control/display stereotypes, can be the same as that for adult populations. Application When designing devices for children, the relationship between controls and displays can be as for adult populations, for which there are considerable experimental data.

  4. The Risk of Individual Stocks’ Tail Dependence with the Market and Its Effect on Stock Returns

    Directory of Open Access Journals (Sweden)

    Guobin Fan

    2015-01-01

    Full Text Available Traditional beta is only a linear measure of overall market risk and places equal emphasis on upside and downside risks, but actually the latter is always much stronger probably due to the trading mechanism like short-sale constraints. Therefore, this paper employs the nonlinear measure, tail dependence, to measure the extreme downside risks that individual stocks crash together with the whole market and investigates whether such tail dependence risks will affect stock returns. Our empirical evidence based on Shanghai A shares confirms that most stocks display nonnegligible tail dependence with the whole market, and, more importantly, such tail dependence risks can indeed provide additional information beyond beta and other factors for asset pricing. In cross-sectional regression, it is proved that this tail dependence does help to explain monthly returns on Shanghai A shares, whereas the time-series regression further indicates that mimicking portfolio returns for tail dependence can capture strong common variation of Shanghai A stock returns.

  5. Characterizing the reflectivity of handheld display devices.

    Science.gov (United States)

    Liu, Peter; Badano, Aldo

    2014-08-01

    With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using methods recommended by the American Association of Physicists in Medicine Task Group 18 (TG18). The authors modified the diffuse reflectance coefficient measurement method outlined in the TG18 report. The authors measured seven handheld display devices (two phones and five tablets) and three workstation displays. The device was attached to a black panel with Velcro. To study the effect of the back surface on the diffuse reflectance coefficient, the authors created Styrofoam masks with different size square openings and placed it in front of the device. Overall, for each display device, measurements of illuminance and reflected luminance on the display screen were taken. The authors measured with no mask, with masks of varying size, and with display-size masks, and calculated the corresponding diffuse reflectance coefficient. For all handhelds, the diffuse reflectance coefficient measured with no back panel were lower than measurements performed with a mask. The authors found an overall increase in reflectivity as the size of the mask decreases. For workstations displays, diffuse reflectance coefficients were higher when no back panel was used, and higher than with masks. In all cases, as luminance increased, illuminance increased, but not at the same rate. Since the size of handheld displays is smaller than that of workstation devices, the TG18 method suffers from a dependency on illumination condition. The authors show that the diffuse reflection coefficients can vary depending on the nature of the back surface of the illuminating box. The variability in the diffuse coefficient can be as large as 20% depending on the size of the mask. For all measurements

  6. Movement reveals scale dependence in habitat selection of a large ungulate

    Science.gov (United States)

    Northrup, Joseph; Anderson, Charles R.; Hooten, Mevin B.; Wittemyer, George

    2016-01-01

    Ecological processes operate across temporal and spatial scales. Anthropogenic disturbances impact these processes, but examinations of scale dependence in impacts are infrequent. Such examinations can provide important insight to wildlife–human interactions and guide management efforts to reduce impacts. We assessed spatiotemporal scale dependence in habitat selection of mule deer (Odocoileus hemionus) in the Piceance Basin of Colorado, USA, an area of ongoing natural gas development. We employed a newly developed animal movement method to assess habitat selection across scales defined using animal-centric spatiotemporal definitions ranging from the local (defined from five hour movements) to the broad (defined from weekly movements). We extended our analysis to examine variation in scale dependence between night and day and assess functional responses in habitat selection patterns relative to the density of anthropogenic features. Mule deer displayed scale invariance in the direction of their response to energy development features, avoiding well pads and the areas closest to roads at all scales, though with increasing strength of avoidance at coarser scales. Deer displayed scale-dependent responses to most other habitat features, including land cover type and habitat edges. Selection differed between night and day at the finest scales, but homogenized as scale increased. Deer displayed functional responses to development, with deer inhabiting the least developed ranges more strongly avoiding development relative to those with more development in their ranges. Energy development was a primary driver of habitat selection patterns in mule deer, structuring their behaviors across all scales examined. Stronger avoidance at coarser scales suggests that deer behaviorally mediated their interaction with development, but only to a degree. At higher development densities than seen in this area, such mediation may not be possible and thus maintenance of sufficient

  7. Stronger interference from distractors in the right hemifield during visual search.

    Science.gov (United States)

    Carlei, Christophe; Kerzel, Dirk

    2018-03-01

    The orientation-bias hypothesis states that there is a bias to attend to the right visual hemifield (RVF) when there is spatial competition between stimuli in the left and right hemifield [Pollmann, S. (1996). A pop-out induced extinction-like phenomenon in neurologically intact subjects. Neuropsychologia, 34(5), 413-425. doi: 10.1016/0028-3932(95)00125-5 ]. In support of this hypothesis, stronger interference was reported for RVF distractors with contralateral targets. In contrast, previous studies using rapid serial visual presentation (RSVP) found stronger interference from distractors in the left visual hemifield (LVF). We used the additional singleton paradigm to test whether this discrepancy was due to the different distractor features that were employed (colour vs. orientation). Interference from the colour distractor with contralateral targets was larger in the RVF than in the LVF. However, the asymmetrical interference disappeared when observers had to search for an inconspicuous colour target instead of the inconspicuous shape target. We suggest that the LVF orienting-bias is limited to situations where search is driven by bottom-up saliency (singleton search) instead of top-down search goals (feature search). In contrast, analysis of the literature suggests the opposite for the LVF bias in RSVP tasks. Thus, the attentional asymmetry may depend on whether the task involves temporal or spatial competition, and whether search is based on bottom-up or top-down signals.

  8. Relations between emotions, display rules, social motives, and facial behaviour.

    Science.gov (United States)

    Zaalberg, Ruud; Manstead, Antony; Fischer, Agneta

    2004-02-01

    We report research on the relations between emotions, display rules, social motives, and facial behaviour. In Study 1 we used a questionnaire methodology to examine how respondents would react to a funny or a not funny joke told to them by a close friend or a stranger. We assessed display rules and motivations for smiling and/or laughing. Display rules and social motives (partly) mediated the relationship between the experimental manipulations and self-reported facial behaviour. Study 2 was a laboratory experiment in which funny or not funny jokes were told to participants by a male or female stranger. Consistent with hypotheses, hearing a funny joke evoked a stronger motivation to share positive affect by showing longer Duchenne smiling. Contrary to hypotheses, a not funny joke did not elicit greater prosocial motivation by showing longer "polite" smiling, although such a smiling pattern did occur. Rated funniness of the joke and the motivation to share positive affect mediated the relationship between the joke manipulation and facial behaviour. Path analysis was used to explore this mediating process in greater detail.

  9. A vanadium-dependent bromoperoxidase in the marine red alga Kappaphycus alvarezii (Doty) Doty displays clear substrate specificity.

    Science.gov (United States)

    Kamenarska, Zornitsa; Taniguchi, Tomokazu; Ohsawa, Noboru; Hiraoka, Masanori; Itoh, Nobuya

    2007-05-01

    Bromoperoxidase activity was initially detected in marine macroalgae belonging to the Solieriaceae family (Gigartinales, Rhodophyta), including Solieria robusta (Greville) Kylin, Eucheuma serra J. Agardh and Kappaphycus alvarezii (Doty) Doty, which are important industrial sources of the polysaccharide carrageenan. Notably, the purification of bromoperoxidase was difficult because due to the coexistence of viscoid polysaccharides. The activity of the partially purified enzyme was dependent on the vanadate ion, and displayed a distinct substrate spectrum from that of previously reported vanadium-dependent bromoperoxidases of marine macroalgae. The enzyme was specific for Br- and I- ions and inactive toward F- and Cl-. The K(m) values for Br- and H2O2 were 2.5x10(-3) M and 8.5x10(-5) M, respectively. The halogenated product, dibromoacetaldehyde, that accumulated in K. alvarezii was additionally determined.

  10. Tumour exosomes display different differential mechanical and complement activation properties dependent on malignant state: implications in endothelial leakiness

    DEFF Research Database (Denmark)

    Whitehead, Bradley Joseph; Wu, Linping; Hvam, Michael Lykke

    2015-01-01

    (QNM AFM) to determine size and nanomechanical properties. Effect of HCV-29, T24 and FL3 exosomes on human umbilical vein endothelial cell (HUVEC) monolayer integrity was determined by transendothelial electrical resistance (TEER) measurements and transport was determined by flow cytometry. Complement......). Malignant cell-derived exosomes activated complement through calcium-sensitive pathways in a concentration-dependent manner. Conclusions : Malignant (metastatic and non-metastatic) cell line exosomes display a markedly reduced stiffness and adhesion but an increased complement activation compared to non...

  11. Display Rules for Anger and Aggression in School-Age Children.

    Science.gov (United States)

    Underwood, Marion K.; And Others

    1992-01-01

    Two studies examined the development of display rules for anger and the relationship between the use of display rules for anger and aggressiveness as rated by school peers. Findings indicate that the phenomenon of display rules for anger is complex and depends on the way display rules are defined and the age and gender of the subjects. (GLR)

  12. Preferred Color Gamut Boundaries for Wide-Gamut and Multi-Primary Displays

    NARCIS (Netherlands)

    Murdoch, M.J.; Sekulovski, S.D.; Heynderickx, I.E.J.

    2012-01-01

    Preferred chroma enhancement and its dependence on hue were studiedin a two-part experiment using a wide-gamut multi-primary display.This builds on earlier experiments which showed a clear hue dependence but were limited by the gamut of the display they employed. In the first part of this

  13. Women's political participation leads to stronger local economies ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2016-06-08

    Jun 8, 2016 ... Under changes to India's constitution, Indian women are gaining a stronger ... Legal reforms are encouraging women to contribute to economic growth ... on a panel on empowering women entrepreneurs at IDRC in Ottawa.

  14. Chemical reaction due to stronger Ramachandran interaction

    Indian Academy of Sciences (India)

    The origin of a chemical reaction between two reactant atoms is associated with the activation energy, on the assumption that, high-energy collisions between these atoms, are the ones that overcome the activation energy. Here, we show that a stronger attractive van der Waals (vdW) and electron-ion Coulomb interactions ...

  15. Discovery of Paradigm Dependencies

    OpenAIRE

    Sun, Jizhou; Li, Jianzhong; Gao, Hong

    2017-01-01

    Missing and incorrect values often cause serious consequences. To deal with these data quality problems, a class of common employed tools are dependency rules, such as Functional Dependencies (FDs), Conditional Functional Dependencies (CFDs) and Edition Rules (ERs), etc. The stronger expressing ability a dependency has, data with the better quality can be obtained. To the best of our knowledge, all previous dependencies treat each attribute value as a non-splittable whole. Actually however, i...

  16. Stronger relationship of serum apolipoprotein A-1 and B with diabetic retinopathy than traditional lipids

    Directory of Open Access Journals (Sweden)

    B S Ankit

    2017-01-01

    Full Text Available Aim: Diabetic retinopathy (DR is the most common preventable cause of blindness where early detection and treatment can be sight-saving. Search for biomarkers of the disease has been relentless. We aimed to determine whether lipoproteins apolipoproteins A1 and B1 (Apo-A1 and Apo-B1 have stronger associations with DR in contrast to conventionally measured low-density lipoprotein (LDL and high-density lipoprotein cholesterol levels. Materials and Methods: We performed a cross-sectional study and studied 117 patients. Serum lipid profile was assessed by autoanalyzer. Serum Apo-A1 and Apo-B were measured using immunoturbidimetric kit on an autoanalyzer. Apo-B/A1 ratio was calculated. Retinopathy was graded from the digital retinal photographs, taken with nonmydriatic auto fundus camera and classified according to International Clinical DR Disease Severity Scale. Results: Mean Apo-A1 for mild, moderate, severe retinopathy, and proliferative DR (PDR shows a significant negative correlation (P = 0.001 with severity of retinopathy. Mean Apo-B for mild, moderate, severe, PDR displayed a significant positive correlation with severity of retinopathy (P = 0.001. Mean Apo-B/A1 for mild, moderate, severe, PDR showed highly significant positive correlation with severity of retinopathy (P < 0.001. In contrast, mean LDL for mild, moderate, severe, PDR showed insignificant association with severity of DR (P = 0.081. Conclusion: Apo-A1 and Apo-B have a stronger association with the development of DR than traditional lipids and can thus facilitate early detection and treatment of the disease.

  17. Prosocial Choice in Rats Depends on Food-Seeking Behavior Displayed by Recipients.

    Science.gov (United States)

    Márquez, Cristina; Rennie, Scott M; Costa, Diana F; Moita, Marta A

    2015-06-29

    Animals often are prosocial, displaying behaviors that result in a benefit to one another [1-15] even in the absence of self-benefit [16-21] (but see [22-25]). Several factors have been proposed to modulate these behaviors, namely familiarity [6, 13, 18, 20] or display of seeking behavior [16, 21]. Rats have been recently shown to be prosocial under distress [17, 18] (but see [26-29]); however, what drives prosociality in these animals remains unclear. To address this issue, we developed a two-choice task in which prosocial behavior did not yield a benefit or a cost to the focal rat. We used a double T-maze in which only the focal rat controlled access to the food-baited arms of its own and the recipient rat's maze. In this task, the focal rat could choose between one side of the maze, which yielded food only to itself (selfish choice), and the opposite side, which yielded food to itself and the recipient rat (prosocial choice). Rats showed a high proportion of prosocial choices. By manipulating reward delivery to the recipient and its ability to display a preference for the baited arm, we found that the display of food-seeking behavior leading to reward was necessary to drive prosocial choices. In addition, we found that there was more social investigation between rats in selfish trials than in prosocial trials, which may have influenced the focals' choices. This study shows that rats provide access to food to others in the absence of added direct self-benefit, bringing new insights into the factors that drive prosociality. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. The right of the stronger: The play Sisyphus and critias

    Directory of Open Access Journals (Sweden)

    Jordović Ivan

    2004-01-01

    Full Text Available The Focus of this study is the standpoint of the play Sisyphus and critias the leader of the thirty towards the right of the stronger. this is a question of constant interest in scientific circles, since its answer can serve as the indicator of the influence this famous theory has had. this interest has been encouraged by the fact that critias’ authorship of the play is questionable. however, the question of the author is not of primary importance for this article, because there are some arguments, among some well known ones, which were not considered and which Show that in this satire, regardless of the author and the purpose of this fragment, the right of the stronger is actually non-existant. the first argument to support this theory is that nomosphysis antithesis is nowhere explicitly mentioned although it is the crucial element of the right of the stronger. in addition there is no claim in the play that the exploitation of the strong by the week or by law accrued. the second argument is that despite the incapability of laws to prevent the secret injustice, they and their importance for the human society are depicted in a positive light. it should also be noted that, unlike callicles and glaucon, laws are created to stop the bad and not the good. the third argument is that the invention of religion is accepted as a positive achievement, which finally enables the overcoming of primeval times and lawlessness. the reflection of this argument is a positive characterization of the individual who invented the fear of gods. the fourth argument, which has not been taken into consideration so far is the way the supporters and opponents of lawlessness are described and marked as κακοί and έσξλοί in the satire only physically strong are considered as strong as opposed to callicles, where they are also spiritually superior. intelectually superior in Sisyphus is the inventor of the fear of gods who is also in favor of law and order. the fact

  19. Women's political participation leads to stronger local economies ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Edgard Rodriguez - IDRC. Women attend a self-help group meeting near Hyderabad, India. Keenara Khanderia. Under changes to India's constitution, Indian women are gaining a stronger political voice. Legal reforms are encouraging women to contribute to economic growth and investments in community growth.

  20. Mucosal vaccination by adenoviruses displaying reovirus sigma 1

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, Eric A. [Department of Internal Medicine, Division of Infectious Diseases, Translational Immunovirology and Biodefense Program, Mayo Clinic, Rochester, MN 55902 (United States); Camacho, Zenaido T. [Department of Cell Biology, Department of Natural Sciences, Western New Mexico University, Silver City, NM 88062 (United States); Hillestad, Matthew L. [Nephrology Training Program, Mayo Clinic, Rochester, MN 55902 (United States); Crosby, Catherine M.; Turner, Mallory A.; Guenzel, Adam J.; Fadel, Hind J. [Virology and Gene Therapy Graduate Program, Mayo Clinic, Rochester, MN 55902 (United States); Mercier, George T. [Department of Physics, University of Houston, Houston, TX 77004 (United States); Barry, Michael A., E-mail: mab@mayo.edu [Department of Internal Medicine, Division of Infectious Diseases, Translational Immunovirology and Biodefense Program, Mayo Clinic, Rochester, MN 55902 (United States); Department of Immunology and Department of Molecular Medicine, Mayo Clinic, Rochester, MN 55902 (United States)

    2015-08-15

    We developed adenovirus serotype 5 (Ad5) vectors displaying the sigma 1 protein from reovirus as mucosal vaccines. Ad5-sigma retargets to JAM-1 and sialic acid, but has 40-fold reduced gene delivery when compared to Ad5. While weaker at transduction, Ad5-sigma generates stronger T cell responses than Ad5 when used for mucosal immunization. In this work, new Ad5-fiber-sigma vectors were generated by varying the number of fiber β-spiral shaft repeats (R) between the fiber tail and sigma. Increasing chimera length led to decreasing insertion of these proteinsAd5 virions. Ad-R3 and R14 vectors effectively targeted JAM-1 in vitro while R20 did not. When wereused to immunize mice by the intranasal route, Ad5-R3-sigma produced higher serum and vaginal antibody responses than Ad5. These data suggest optimized Ad-sigma vectors may be useful vectors for mucosal vaccination. - Highlights: • Constructed adenoviruses (Ads) displaying different reovirus sigma 1 fusion proteins. • Progressively longer chimeras were more poorly encapsidated onto Ad virions. • Ad5-R3-sigma mediated better systemic and mucosal immune responses than Ad5.

  1. Mucosal vaccination by adenoviruses displaying reovirus sigma 1

    International Nuclear Information System (INIS)

    Weaver, Eric A.; Camacho, Zenaido T.; Hillestad, Matthew L.; Crosby, Catherine M.; Turner, Mallory A.; Guenzel, Adam J.; Fadel, Hind J.; Mercier, George T.; Barry, Michael A.

    2015-01-01

    We developed adenovirus serotype 5 (Ad5) vectors displaying the sigma 1 protein from reovirus as mucosal vaccines. Ad5-sigma retargets to JAM-1 and sialic acid, but has 40-fold reduced gene delivery when compared to Ad5. While weaker at transduction, Ad5-sigma generates stronger T cell responses than Ad5 when used for mucosal immunization. In this work, new Ad5-fiber-sigma vectors were generated by varying the number of fiber β-spiral shaft repeats (R) between the fiber tail and sigma. Increasing chimera length led to decreasing insertion of these proteinsAd5 virions. Ad-R3 and R14 vectors effectively targeted JAM-1 in vitro while R20 did not. When wereused to immunize mice by the intranasal route, Ad5-R3-sigma produced higher serum and vaginal antibody responses than Ad5. These data suggest optimized Ad-sigma vectors may be useful vectors for mucosal vaccination. - Highlights: • Constructed adenoviruses (Ads) displaying different reovirus sigma 1 fusion proteins. • Progressively longer chimeras were more poorly encapsidated onto Ad virions. • Ad5-R3-sigma mediated better systemic and mucosal immune responses than Ad5

  2. Facial Displays Are Tools for Social Influence.

    Science.gov (United States)

    Crivelli, Carlos; Fridlund, Alan J

    2018-05-01

    Based on modern theories of signal evolution and animal communication, the behavioral ecology view of facial displays (BECV) reconceives our 'facial expressions of emotion' as social tools that serve as lead signs to contingent action in social negotiation. BECV offers an externalist, functionalist view of facial displays that is not bound to Western conceptions about either expressions or emotions. It easily accommodates recent findings of diversity in facial displays, their public context-dependency, and the curious but common occurrence of solitary facial behavior. Finally, BECV restores continuity of human facial behavior research with modern functional accounts of non-human communication, and provides a non-mentalistic account of facial displays well-suited to new developments in artificial intelligence and social robotics. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Subjective usability of speech, touch and gesture in a heterogeneous multi-display environment

    NARCIS (Netherlands)

    Jong, A.P.J. de; Tak, S.; Toet, A.; Schultz, S.; Wijbenga, J.P.; Erp, J.B.F. van

    2013-01-01

    Several interaction techniques have been proposed to enable transfer of information between different displays in heterogeneous multi-display environments. However, it is not clear whether subjective user preference for these different techniques depends on the nature of the displays between which

  4. 3D display system using monocular multiview displays

    Science.gov (United States)

    Sakamoto, Kunio; Saruta, Kazuki; Takeda, Kazutoki

    2002-05-01

    A 3D head mounted display (HMD) system is useful for constructing a virtual space. The authors have researched the virtual-reality systems connected with computer networks for real-time remote control and developed a low-priced real-time 3D display for building these systems. We developed a 3D HMD system using monocular multi-view displays. The 3D displaying technique of this monocular multi-view display is based on the concept of the super multi-view proposed by Kajiki at TAO (Telecommunications Advancement Organization of Japan) in 1996. Our 3D HMD has two monocular multi-view displays (used as a visual display unit) in order to display a picture to the left eye and the right eye. The left and right images are a pair of stereoscopic images for the left and right eyes, then stereoscopic 3D images are observed.

  5. Circular displays: control/display arrangements and stereotype strength with eight different display locations.

    Science.gov (United States)

    Chan, Alan H S; Hoffmann, Errol R

    2015-01-01

    Two experiments are reported that were designed to investigate control/display arrangements having high stereotype strengths when using circular displays. Eight display locations relative to the operator and control were tested with rotational and translational controls situated on different planes according to the Frame of Reference Transformation Tool (FORT) model of Wickens et al. (2010). (Left. No, Right! Development of the Frame of Reference Transformation Tool (FORT), Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting, 54: 1022-1026). In many cases, there was little effect of display locations, indicating the importance of the Worringham and Beringer (1998. Directional stimulus-response compatibility: a test of three alternative principles. Ergonomics, 41(6), 864-880) Visual Field principle and an extension of this principle for rotary controls (Hoffmann and Chan (2013). The Worringham and Beringer 'visual field' principle for rotary controls. Ergonomics, 56(10), 1620-1624). The initial indicator position (12, 3, 6 and 9 o'clock) had a major effect on control/display stereotype strength for many of the six controls tested. Best display/control arrangements are listed for each of the different control types (rotational and translational) and for the planes on which they are mounted. Data have application where a circular display is used due to limited display panel space and applies to space-craft, robotics operators, hospital equipment and home appliances. Practitioner Summary: Circular displays are often used when there is limited space available on a control panel. Display/control arrangements having high stereotype strength are listed for four initial indicator positions. These arrangements are best for design purposes.

  6. LHC Season 2: A stronger machine

    CERN Multimedia

    Dominguez, Daniel

    2015-01-01

    1) New magnets / De nouveaux aimants 2) Stronger connections / Des jonctions électriques renforcées 3) Safer magnets / Des aimants plus sûrs 4) Higher energy beams / Des faisceaux d’énergie plus élevée 5) Narrower beams / Des faisceaux plus serrés 6) Smaller but closer proton packets / Des groupes de protons plus petits mais plus rapprochés 7) Higher voltage / Une tension plus haute 8) Superior cryogenics / Un système cryogénique amélioré 9) Radiation-resistant electronics / Une électronique qui résiste aux radiations 10) More secure vacuum / Un vide plus sûr

  7. Lower-Body Muscle Structure and Jump Performance of Stronger and Weaker Surfing Athletes.

    Science.gov (United States)

    Secomb, Josh L; Nimphius, Sophia; Farley, Oliver R; Lundgren, Lina; Tran, Tai T; Sheppard, Jeremy M

    2016-07-01

    To identify whether there are any significant differences in the lower-body muscle structure and countermovement-jump (CMJ) and squat-jump (SJ) performance between stronger and weaker surfing athletes. Twenty elite male surfers had their lower-body muscle structure assessed with ultrasonography and completed a series of lower-body strength and jump tests including isometric midthigh pull (IMTP), CMJ, and SJ. Athletes were separated into stronger (n = 10) and weaker (n = 10) groups based on IMTP performance. Large significant differences were identified between the groups for vastus lateralis (VL) thickness (P = .02, ES = 1.22) and lateral gastrocnemius (LG) pennation angle (P = .01, ES = 1.20), and a large nonsignificant difference was identified in LG thickness (P = .08, ES = 0.89). Furthermore, significant differences were present between the groups for peak force, relative peak force, and jump height in the CMJ and SJ (P Stronger surfing athletes in this study had greater VL and LG thickness and LG pennation angle. These muscle structures may explain their better performance in the CMJ and SJ. A unique finding in this study was that the stronger group appeared to better use their strength and muscle structure for braking as they had significantly higher eccentric peak velocity and vertical displacement during the CMJ. This enhanced eccentric phase may have resulted in a greater production and subsequent utilization of stored elastic strain energy that led to the significantly better CMJ performance in the stronger group.

  8. The effect of display movement angle, indicator type and display location on control/display stereotype strength.

    Science.gov (United States)

    Hoffmann, Errol R; Chan, Alan H S

    2017-08-01

    Much research on stereotype strength relating display and control movements for displays moving in the vertical or horizontal directions has been reported. Here we report effects of display movement angle, where the display moves at angles (relative to the vertical) of between 0° and 180°. The experiment used six different controls, four display locations relative to the operator and three types of indicator. Indicator types were included because of the strong effects of the 'scale-side principle' that are variable with display angle. A directional indicator had higher stereotype strength than a neutral indicator, and showed an apparent reversal in control/display stereotype direction beyond an angle of 90°. However, with a neutral indicator this control reversal was not present. Practitioner Summary: The effects of display moving at angles other than the four cardinal directions, types of control, location of display and types of indicator are investigated. Indicator types (directional and neutral) have an effect on stereotype strength and may cause an apparent control reversal with change of display movement angle.

  9. Evaluation of technical design of advanced information display

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Woo Chang; Kang, Young Ju; Ji, Jung Hun; Jang, Sung Pil; Jung, Sung Hae [Kumoh National Institute of Technology, Gumi (Korea, Republic of)

    2003-03-15

    The performance of human machine system such as nuclear power plant is highly dependent on the suitability of the interface design of the system. As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on CRT or CBP (Computer Based Procedure). This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing information display on CRT by finding the generic guidelines involving information display design issues as much as possible. The design Issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices.

  10. Evaluation of technical design of advanced information display

    International Nuclear Information System (INIS)

    Cha, Woo Chang; Kang, Young Ju; Ji, Jung Hun; Jang, Sung Pil; Jung, Sung Hae

    2003-03-01

    The performance of human machine system such as nuclear power plant is highly dependent on the suitability of the interface design of the system. As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on CRT or CBP (Computer Based Procedure). This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing information display on CRT by finding the generic guidelines involving information display design issues as much as possible. The design Issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices

  11. Human factors considerations for the use of color in display systems

    Science.gov (United States)

    Demars, S. A.

    1975-01-01

    Identified and assessed are those human factor considerations impacting an operator's ability to perform when information is displayed in color as contrasted to monochrome (black and white only). The findings provide valuable guidelines for the assessment of the advantages (and disadvantages) of using a color display system. The use of color provides an additional sensory channel (color perception) which is not available with black and white. The degree to which one can exploit the use of this channel is highly dependent on available display technology, mission information display requirements, and acceptable operational modes.

  12. Enhancing Electrophoretic Display Lifetime: Thiol-Polybutadiene Evaporation Barrier Property Response to Network Microstructure

    Energy Technology Data Exchange (ETDEWEB)

    Cook, Caitlyn Christian [California State Polytechnic State Univ., San Luis Obispo, CA (United States)

    2017-02-27

    11%, respectively. Oscillatory real-time rheological experiments confirmed a more uniform network to better dissipate applied shear in short chain length dithiol systems, as long chain length dithiols relayed a steep internal stress build-up due to less cross-links and chain entanglements. Thorough understanding of network formation aids the production of a stronger and impermeable elastomeric barrier for preservation of EPD displays.

  13. Blown by the wind: the ecology of male courtship display behavior in orchid bees.

    Science.gov (United States)

    Pokorny, Tamara; Vogler, Ira; Losch, René; Schlütting, Patrick; Juarez, Pedro; Bissantz, Nicolai; Ramírez, Santiago R; Eltz, Thomas

    2017-04-01

    Many insects rely on chemical signals to transmit precise information on the location, identity, and quality of potential mates. Chemical signals are often broadcasted at sites with physical properties that maximize signal propagation and signal transmission. Male neotropical orchid bees (Euglossini) perch and display on vertical branches and tree trunks in the forest to expose volatile blends (perfumes) that they previously collected from their environment. Previous studies have shown that the chemical composition of perfume blends is highly differentiated even between closely related species. However, variation in behavioral components of perfume exposure and male display remain poorly understood. We conducted a four-year study on orchid bee display sites (8 species) in pacific Costa Rica, using field observations along with chemical analysis and cage experiments to assess display niche partitioning among sympatric species. We evaluated the influence of physical factors (terrain, wind, light) on the distribution of perch sites and on display behavior, and tested a prediction of the sex pheromone-analogue hypothesis, i.e., that displaying males have above-average quantities or qualities of acquired perfumes. Males of different species displayed in the same general area and sometimes in close proximity to each other, but partitioned the display niche by selecting different perch diameters, display heights, and by displaying at different times of the day. Most perch sites were located inside the forest on elevated ground, especially along ridges, where stronger winds may help disperse perfume signals. Furthermore, the angular position of displaying males on perches was narrowly determined by wind direction, with males being positioned on the downwind side of the perch, where they would be most conspicuous to conspecifics approaching on an odor trail. Although our results generally support the hypothesis that perfumes serve as pheromone analogues, we did not find

  14. Natural display mode for digital DICOM-conformant diagnostic imaging.

    Science.gov (United States)

    Peters, Klaus-Ruediger; Ramsby, Gale R

    2002-09-01

    The authors performed this study to investigate the verification of the contrast display properties defined by the digital imaging and communication in medicine (DICOM) PS (picture archiving and communication system [PACS] standard) 3.14-2001 gray-scale display function standard and their dependency on display luminance range and video signal bandwidth. Contrast sensitivity and contrast linearity of DICOM-conformant displays were measured in just-noticeable differences (JNDs) on special perceptual contrast test patterns. Measurements were obtained six times at various display settings under dark room conditions. Display luminance range and video bandwidth had a significant effect on contrast perception. The perceptual promises of the standard could be established only with displays that were calibrated to a unity contrast resolution, at which the number of displayed intensity steps was equal to the number of perceivable contrast steps (JNDs). Such display conditions provide for visual perception information at the level of single-step contrast sensitivity and full-range contrast linearity. These "natural display" conditions also help minimize the Mach banding effects that otherwise reduce contrast sensitivity and contrast linearity. Most, if not all, conventionally used digital display modalities are driven with a contrast resolution larger than 1. Such conditions reduce contrast perception when compared with natural imaging conditions. The DICOM-conformant display conditions at unity contrast resolution were characterized as the "natural display" mode, and, thus, the authors a priori recommend them as being useful for making a primary diagnosis with PACS and teleradiology and as a standard for psychophysical research and performance measurements.

  15. A Stronger Reason for the Right to Sign Languages

    Science.gov (United States)

    Trovato, Sara

    2013-01-01

    Is the right to sign language only the right to a minority language? Holding a capability (not a disability) approach, and building on the psycholinguistic literature on sign language acquisition, I make the point that this right is of a stronger nature, since only sign languages can guarantee that each deaf child will properly develop the…

  16. Advances in infrastructure support for flat panel display manufacturing

    Science.gov (United States)

    Bardsley, James N.; Ciesinski, Michael F.; Pinnel, M. Robert

    1997-07-01

    The success of the US display industry, both in providing high-performance displays for the US Department of Defense at reasonable cost and in capturing a significant share of the global civilian market, depends on maintaining technological leadership and on building efficient manufacturing capabilities. The US Display Consortium (USDC) was set up in 1993 by the US Government and private industry to guide the development of the infrastructure needed to support the manufacturing of flat panel displays. This mainly involves the supply of equipment and materials, but also includes the formation of partnerships and the training of a skilled labor force. Examples are given of successful development projects, some involving USDC participation, others through independent efforts of its member companies. These examples show that US-based companies can achieve leadership positions in this young and rapidly growing global market.

  17. Stronger vection in junior high school children than in adults.

    Science.gov (United States)

    Shirai, Nobu; Imura, Tomoko; Tamura, Rio; Seno, Takeharu

    2014-01-01

    Previous studies have shown that even elementary school-aged children (7 and 11 years old) experience visually induced perception of illusory self-motion (vection) (Lepecq et al., 1995, Perception, 24, 435-449) and that children of a similar age (mean age = 9.2 years) experience more rapid and stronger vection than do adults (Shirai et al., 2012, Perception, 41, 1399-1402). These findings imply that although elementary school-aged children experience vection, this ability is subject to further development. To examine the subsequent development of vection, we compared junior high school students' (N = 11, mean age = 14.4 years) and adults' (N = 10, mean age = 22.2 years) experiences of vection. Junior high school students reported significantly stronger vection than did adults, suggesting that the perceptual experience of junior high school students differs from that of adults with regard to vection and that this ability undergoes gradual changes over a relatively long period of development.

  18. A virtual image chain for perceived image quality of medical display

    Science.gov (United States)

    Marchessoux, Cédric; Jung, Jürgen

    2006-03-01

    This paper describes a virtual image chain for medical display (project VICTOR: granted in the 5th framework program by European commission). The chain starts from raw data of an image digitizer (CR, DR) or synthetic patterns and covers image enhancement (MUSICA by Agfa) and both display possibilities, hardcopy (film on viewing box) and softcopy (monitor). Key feature of the chain is a complete image wise approach. A first prototype is implemented in an object-oriented software platform. The display chain consists of several modules. Raw images are either taken from scanners (CR-DR) or from a pattern generator, in which characteristics of DR- CR systems are introduced by their MTF and their dose-dependent Poisson noise. The image undergoes image enhancement and comes to display. For soft display, color and monochrome monitors are used in the simulation. The image is down-sampled. The non-linear response of a color monitor is taken into account by the GOG or S-curve model, whereas the Standard Gray-Scale-Display-Function (DICOM) is used for monochrome display. The MTF of the monitor is applied on the image in intensity levels. For hardcopy display, the combination of film, printer, lightbox and viewing condition is modeled. The image is up-sampled and the DICOM-GSDF or a Kanamori Look-Up-Table is applied. An anisotropic model for the MTF of the printer is applied on the image in intensity levels. The density-dependent color (XYZ) of the hardcopy film is introduced by Look-Up-tables. Finally a Human Visual System Model is applied to the intensity images (XYZ in terms of cd/m2) in order to eliminate nonvisible differences. Comparison leads to visible differences, which are quantified by higher order image quality metrics. A specific image viewer is used for the visualization of the intensity image and the visual difference maps.

  19. European display scene

    Science.gov (United States)

    Bartlett, Christopher T.

    2000-08-01

    The manufacture of Flat Panel Displays (FPDs) is dominated by Far Eastern sources, particularly in Active Matrix Liquid Crystal Displays (AMLCD) and Plasma. The United States has a very powerful capability in micro-displays. It is not well known that Europe has a very active research capability which has lead to many innovations in display technology. In addition there is a capability in display manufacturing of organic technologies as well as the licensed build of Japanese or Korean designs. Finally, Europe has a display systems capability in military products which is world class.

  20. Effect of display location on control-display stereotype strength for translational and rotational controls with linear displays.

    Science.gov (United States)

    Chan, Alan H S; Hoffmann, Errol R

    2015-01-01

    Experiments were designed to investigate the effects of control type and display location, relative to the operator, on the strength of control/display stereotypes. The Worringham and Beringer Visual Field principle and an extension of this principle for rotary controls (Hoffmann E.R., and Chan A.H.S. 2013). "The Worringham and Beringer 'Visual Field' Principle for Rotary Controls. Ergonomics." 56 (10): 1620-1624) indicated that, for a number of different control types (rotary and lever) on different planes, there should be no significant effect of the display location relative to the seated operator. Past data were surveyed and stereotype strengths listed. Experiments filled gaps where data are not available. Six different control types and seven display locations were used, as in the Frame of Reference Transformation Tool (FORT) model of Wickens et al. (Wickens, C.D., Keller, J.W., and Small, R.L. (2010). "Left. No, Right! Development of the Frame of Reference Transformation Tool (FORT)." Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting September 2010, 54: 1022-1026). Control/display arrangements with high stereotype strengths were evaluated yielding data for designers of complex control/display arrangements where the control and display are in different planes and for where the operator is moving. It was found possible to predict display/control arrangements with high stereotype strength, based on past data. Practitioner Summary: Controls and displays in complex arrangements need to have high compatibility. These experiments provide arrangements for six different controls (rotary and translational) and seven different display locations relative to the operator.

  1. Displays in scintigraphy

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.E.; Pizer, S.M.

    1977-01-01

    Displays have several functions: to transmit images, to permit interaction, to quantitate features and to provide records. The main characteristics of displays used for image transmission are their resolution, dynamic range, signal-to-noise ratio and uniformity. Considerations of visual acuity suggest that the display element size should be much less than the data element size, and in current practice at least 256X256 for a gamma camera image. The dynamic range for image transmission should be such that at least 64 levels of grey (or equivalent) are displayed. Scanner displays are also considered, and in particular, the requirements of a whole-body camera are examined. A number of display systems and devices are presented including a 'new' heated object colour display system. Interaction with displays is considered, including background subtraction, contrast enhancement, position indication and region-of-interest generation. Such systems lead to methods of quantitation, which imply knowledge of the expected distributions. Methods for intercomparing displays are considered. Polaroid displays, which have for so long dominated the field, are in the process of being replaced by stored image displays, now that large cheap memories exist which give an equivalent image quality. The impact of this in nuclear medicine is yet to be seen, but a major effect will be to enable true quantitation. (author)

  2. Halo Intrinsic Alignment: Dependence on Mass, Formation Time, and Environment

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Qianli; Kang, Xi; Wang, Peng; Luo, Yu [Purple Mountain Observatory, the Partner Group of MPI für Astronomie, 2 West Beijing Road, Nanjing 210008 (China); Yang, Xiaohu; Jing, Yipeng [Center for Astronomy and Astrophysics, Shanghai Jiao Tong University, Shanghai 200240 (China); Wang, Huiyuan [Key Laboratory for Research in Galaxies and Cosmology, Department of Astronomy, University of Science and Technology of China, Hefei, Anhui 230026 (China); Mo, Houjun, E-mail: kangxi@pmo.ac.cn [Astronomy Department and Center for Astrophysics, Tsinghua University, Beijing 10084 (China)

    2017-10-10

    In this paper we use high-resolution cosmological simulations to study halo intrinsic alignment and its dependence on mass, formation time, and large-scale environment. In agreement with previous studies using N -body simulations, it is found that massive halos have stronger alignment. For the first time, we find that for a given halo mass older halos have stronger alignment and halos in cluster regions also have stronger alignment than those in filaments. To model these dependencies, we extend the linear alignment model with inclusion of halo bias and find that the halo alignment with its mass and formation time dependence can be explained by halo bias. However, the model cannot account for the environment dependence, as it is found that halo bias is lower in clusters and higher in filaments. Our results suggest that halo bias and environment are independent factors in determining halo alignment. We also study the halo alignment correlation function and find that halos are strongly clustered along their major axes and less clustered along the minor axes. The correlated halo alignment can extend to scales as large as 100 h {sup −1} Mpc, where its feature is mainly driven by the baryon acoustic oscillation effect.

  3. The impact of the visual merchandise display on consumer purchases of luxury brands: the moderating role of cultural capital

    OpenAIRE

    Logkizidou, Maria

    2016-01-01

    This thesis argues that Visual Merchandise Display (VMD) can enhance consumers intentions to buy luxury brands and this influence is stronger for the consumers with higher cultural capital (CC) than those with lower CC. Prior research in store atmospherics has suggested that consumers make inferences about a product, a store or a seller based on high-image or low-image store environment cues. Contemporary research in the luxury retailing literature explores qualitatively, the role of of museo...

  4. Investigation of Energy-Efficient Supermarket Display Cases

    Energy Technology Data Exchange (ETDEWEB)

    Walker, D.H.

    2005-01-21

    Supermarkets represent one of the largest energy-intensive building groups in the commercial sector, consuming 2 to 3 million kWh/yr per store (ES-1). Over half of this energy use is for the refrigeration of food display cases and storage coolers. Display cases are used throughout a supermarket for the merchandising of perishable food products. The cases are maintained at air temperatures ranging from -10 to 35 F, depending upon the type of product stored. The operating characteristics and energy requirements of the refrigeration system are directly related to the refrigeration load. The sources of the display case refrigeration load consist of: (1) Moist and warm air infiltration through the open front of the case--air curtains are employed to inhibit this infiltration, but some ambient air is entrained, which adds a substantial portion to the refrigeration load. (2) Heat conduction through case panels and walls. (3) Thermal radiation from the ambient to the product and display case interior. (4) Internal thermal loads--the use of lights, evaporator fans, periodic defrosts, and antisweat heaters adds to the refrigeration load of the display case as well as directly consuming electric energy. The impact of each of these elements on the refrigeration load is very dependent upon case type (Figure ES-1). For example, air infiltration is the most significant portion of the refrigeration load for open, multi-deck cases, while radiation is the largest part of the load for tub-type cases. The door anti-sweat heaters represent a major share of the refrigeration load for frozen food door reach-in cases. Figure ES-2 shows the distribution of display cases in a typical supermarket (ES-2). Open, multi-deck, medium temperature display cases typically comprise about half of the refrigerated fixtures in a store (ES-3). In addition, medium temperature fixtures and storage coolers account for roughly 70 to 75 percent of the total store refrigeration load with open, multi-deck cases

  5. Monocular display unit for 3D display with correct depth perception

    Science.gov (United States)

    Sakamoto, Kunio; Hosomi, Takashi

    2009-11-01

    A study of virtual-reality system has been popular and its technology has been applied to medical engineering, educational engineering, a CAD/CAM system and so on. The 3D imaging display system has two types in the presentation method; one is a 3-D display system using a special glasses and the other is the monitor system requiring no special glasses. A liquid crystal display (LCD) recently comes into common use. It is possible for this display unit to provide the same size of displaying area as the image screen on the panel. A display system requiring no special glasses is useful for a 3D TV monitor, but this system has demerit such that the size of a monitor restricts the visual field for displaying images. Thus the conventional display can show only one screen, but it is impossible to enlarge the size of a screen, for example twice. To enlarge the display area, the authors have developed an enlarging method of display area using a mirror. Our extension method enables the observers to show the virtual image plane and to enlarge a screen area twice. In the developed display unit, we made use of an image separating technique using polarized glasses, a parallax barrier or a lenticular lens screen for 3D imaging. The mirror can generate the virtual image plane and it enlarges a screen area twice. Meanwhile the 3D display system using special glasses can also display virtual images over a wide area. In this paper, we present a monocular 3D vision system with accommodation mechanism, which is useful function for perceiving depth.

  6. Sexual Dimorphisms of Appendicular Musculoskeletal Morphology Related to Social Display in Cuban Anolis Lizards.

    Science.gov (United States)

    Anzai, Wataru; Cádiz, Antonio; Endo, Hideki

    2015-10-01

    In Anolis lizards, sexual dimorphism has been reported in morphological and ecological traits. Males show larger body size and longer limbs related to territorial combat and courtship display with the dewlap. Although functional-anatomical traits are closely related to locomotor behaviors, differences between sexes in musculoskeletal traits on limbs remain unclear. We explored the relationships among sexual dimorphisms in musculoskeletal morphology, habitat, and locomotor traits in Anolis lizards. Specifically, we examined appendicular musculoskeletal morphology in three species of Cuban Anolis by measuring muscle mass and lengths of moment arms. Through comparisons of crossing locomotion, we found that the runner species possessed larger extensors in hindlimbs, which are advantageous for running, whereas the masses of the humeral and femoral retractors were larger in climber species, allowing these lizards to hold up their bodies and occupy tree substrates. Comparisons between the sexes showed different trends among the three species. Males of A. porcatus, which inhabit narrow branches or leaves, had stronger elbow extensors that maintain the display posture. In contrast, males of A. sagrei, which occupy broad surfaces, did not show sexual differences that affected social display. Moreover, A. bartschi indicated sexual differences despite the absence of dewlapping behavior. Our findings suggest that both sexes show fundamentally similar relationships between muscular morphology and locomotor habits to adapt arboreal or terrestrial substrates, and yet sexual dimorphism in forelimb muscles may additionally affected by male specific display with the dewlap.

  7. 72-directional display having VGA resolution for high-appearance image generation

    Science.gov (United States)

    Takaki, Yasuhiro; Dairiki, Takeshi

    2006-02-01

    The high-density directional display, which was originally developed in order to realize a natural 3D display, is not only a 3D display but also a high-appearance display. The appearances of objects, such as glare and transparency, are the results of the reflection and the refraction of rays. The faithful reproduction of such appearances of objects is impossible using conventional 2D displays because rays diffuse on the display screen. The high-density directional display precisely controls the horizontal ray directions so that it can reproduce the appearances of objects. The fidelity of the reproduction of object appearances depends on the ray angle sampling pitch. The angle sampling pitch is determined by considering the human eye imaging system. In the present study the high-appearance display which has the resolution of 640×400 and emits rays in 72 different horizontal directions with the angle pitch of 0.38° was constructed. Two 72-directional displays were combined, each of which consisted of a high-resolution LCD panel (3,840×2,400) and a slanted lenticular sheet. Two images produced by two displays were superimposed by a half mirror. A slit array was placed at the focal plane of the lenticular sheet for each display to reduce the horizontal image crosstalk in the combined image. The impression analysis shows that the high-appearance display provides higher appearances and presence than the conventional 2D displays do.

  8. An interactive display system for large-scale 3D models

    Science.gov (United States)

    Liu, Zijian; Sun, Kun; Tao, Wenbing; Liu, Liman

    2018-04-01

    With the improvement of 3D reconstruction theory and the rapid development of computer hardware technology, the reconstructed 3D models are enlarging in scale and increasing in complexity. Models with tens of thousands of 3D points or triangular meshes are common in practical applications. Due to storage and computing power limitation, it is difficult to achieve real-time display and interaction with large scale 3D models for some common 3D display software, such as MeshLab. In this paper, we propose a display system for large-scale 3D scene models. We construct the LOD (Levels of Detail) model of the reconstructed 3D scene in advance, and then use an out-of-core view-dependent multi-resolution rendering scheme to realize the real-time display of the large-scale 3D model. With the proposed method, our display system is able to render in real time while roaming in the reconstructed scene and 3D camera poses can also be displayed. Furthermore, the memory consumption can be significantly decreased via internal and external memory exchange mechanism, so that it is possible to display a large scale reconstructed scene with over millions of 3D points or triangular meshes in a regular PC with only 4GB RAM.

  9. Invisible Display in Aluminum

    DEFF Research Database (Denmark)

    Prichystal, Jan Phuklin; Hansen, Hans Nørgaard; Bladt, Henrik Henriksen

    2005-01-01

    Bang & Olufsen a/s has been working with ideas for invisible integration of displays in metal surfaces. Invisible integration of information displays traditionally has been possible by placing displays behind transparent or semitransparent materials such as plastic or glass. The wish for an integ......Bang & Olufsen a/s has been working with ideas for invisible integration of displays in metal surfaces. Invisible integration of information displays traditionally has been possible by placing displays behind transparent or semitransparent materials such as plastic or glass. The wish...... for an integrated display in a metal surface is often ruled by design and functionality of a product. The integration of displays in metal surfaces requires metal removal in order to clear the area of the display to some extent. The idea behind an invisible display in Aluminum concerns the processing of a metal...

  10. Medial temporal lobe-dependent repetition suppression and enhancement due to implicit versus explicit processing of individual repeated search displays

    Directory of Open Access Journals (Sweden)

    Thomas eGeyer

    2012-10-01

    Full Text Available Using visual search, functional magnetic resonance imaging (fMRI and patient studies have demonstrated that medial temporal lobe (MTL structures differentiate repeated from novel displays – even when observers are unaware of display repetitions. This suggests a role for MTL in both explicit and, importantly, implicit learning of repeated sensory information (Greene et al., 2007. However, recent behavioral studies suggest, by examining visual search and recognition performance concurrently, that observers have explicit knowledge of at least some of the repeated displays (Geyer et al., 2010. The aim of the present fMRI study was thus to contribute new evidence regarding the contribution of MTL structures to explicit versus implicit learning in visual search. It was found that MTL activation was increased for explicit and, respectively, decreased for implicit relative to baseline displays. These activation differences were most pronounced in left anterior parahippocampal cortex, especially when observers were highly trained on the repeated displays. The data are taken to suggest that explicit and implicit memory processes are linked within MTL structures, but expressed via functionally separable mechanisms (repetition enhancement vs. -suppression. They further show that repetition effects in visual search would have to be investigated at the display level.

  11. Withaferin-A displays enhanced anxiolytic efficacy without tolerance ...

    African Journals Online (AJOL)

    Withaferin-A dose-dependently (10 tob40 mg/kg) displayed anxiolytic activity, as measured by an increase in open arm exploration time in the elevated plus-maze (EPM), following intraperitoneal (i.p.) administration in rats. Acute administration of withaferin-A at 40.0 mg/kg significantly (P<0.05) increased open arm ...

  12. Advanced Colorimetry of Display Systems: Tetra-Chroma3 Display Unit

    Directory of Open Access Journals (Sweden)

    J. Kaiser

    2005-06-01

    Full Text Available High-fidelity color image reproduction is one of the key issues invisual telecommunication systems, for electronic commerce,telemedicine, digital museum and so on. All colorimetric standards ofdisplay systems are up to the present day trichromatic. But, from theshape of a horseshoe-area of all existing colors in the CIE xychromaticity diagram it follows that with three real reproductivelights, the stated area in the CIE xy chromaticity diagram cannot beoverlaid. The expansion of the color gamut of a display device ispossible in a few ways. In this paper, the way of increasing the numberof primaries is studied. The fourth cyan primary is added to threeconventional ones to enlarge the color gamut of reproduction towardscyans and yellow-oranges. The original method of color management forthis new display unit is introduced. In addition, the color gamut ofthe designed additive-based display is successfully compared with thecolor gamut of a modern subtractive-based system. A display with morethan three primary colors is called a multiprimary color display. Thevery advantageous property of such display is the possibility todisplay metameric colors.

  13. Selector genes display tumor cooperation and inhibition in Drosophila epithelium in a developmental context-dependent manner

    Directory of Open Access Journals (Sweden)

    Ram Prakash Gupta

    2017-11-01

    Full Text Available During animal development, selector genes determine identities of body segments and those of individual organs. Selector genes are also misexpressed in cancers, although their contributions to tumor progression per se remain poorly understood. Using a model of cooperative tumorigenesis, we show that gain of selector genes results in tumor cooperation, but in only select developmental domains of the wing, haltere and eye-antennal imaginal discs of Drosophila larva. Thus, the field selector, Eyeless (Ey, and the segment selector, Ultrabithorax (Ubx, readily cooperate to bring about neoplastic transformation of cells displaying somatic loss of the tumor suppressor, Lgl, but in only those developmental domains that express the homeo-box protein, Homothorax (Hth, and/or the Zinc-finger protein, Teashirt (Tsh. In non-Hth/Tsh-expressing domains of these imaginal discs, however, gain of Ey in lgl− somatic clones induces neoplastic transformation in the distal wing disc and haltere, but not in the eye imaginal disc. Likewise, gain of Ubx in lgl− somatic clones induces transformation in the eye imaginal disc but not in its endogenous domain, namely, the haltere imaginal disc. Our results reveal that selector genes could behave as tumor drivers or inhibitors depending on the tissue contexts of their gains.

  14. Microlaser-based displays

    Science.gov (United States)

    Bergstedt, Robert; Fink, Charles G.; Flint, Graham W.; Hargis, David E.; Peppler, Philipp W.

    1997-07-01

    Laser Power Corporation has developed a new type of projection display, based upon microlaser technology and a novel scan architecture, which provides the foundation for bright, extremely high resolution images. A review of projection technologies is presented along with the limitations of each and the difficulties they experience in trying to generate high resolution imagery. The design of the microlaser based projector is discussed along with the advantage of this technology. High power red, green, and blue microlasers have been designed and developed specifically for use in projection displays. These sources, in combination with high resolution, high contrast modulator, produce a 24 bit color gamut, capable of supporting the full range of real world colors. The new scan architecture, which reduces the modulation rate and scan speeds required, is described. This scan architecture, along with the inherent brightness of the laser provides the fundamentals necessary to produce a 5120 by 4096 resolution display. The brightness and color uniformity of the display is excellent, allowing for tiling of the displays with far fewer artifacts than those in a traditionally tiled display. Applications for the display include simulators, command and control centers, and electronic cinema.

  15. Stronger misdirection in curved than in straight motion

    Directory of Open Access Journals (Sweden)

    Jorge eOtero-Millan

    2011-11-01

    Full Text Available Illusions developed by magicians are a rich and largely untapped source of insight into perception and cognition. Here we show that curved motion, as employed by the magician in a classic sleight of hand trick, generates stronger misdirection than rectilinear motion, and that this difference can be explained by the differential engagement of the smooth pursuit and the saccadic oculomotor systems. This research moreover exemplifies how the magician’s intuitive understanding of the spectator’s mindset can surpass that of the cognitive scientist in specific instances, and that observation-based behavioral insights developed by magicians are worthy of quantitative investigation in the neuroscience laboratory.

  16. Handbook of display technology

    CERN Document Server

    Castellano, Joseph A

    1992-01-01

    This book presents a comprehensive review of technical and commercial aspects of display technology. It provides design engineers with the information needed to select proper technology for new products. The book focuses on flat, thin displays such as light-emitting diodes, plasma display panels, and liquid crystal displays, but it also includes material on cathode ray tubes. Displays include a large number of products from televisions, auto dashboards, radios, and household appliances, to gasoline pumps, heart monitors, microwave ovens, and more.For more information on display tech

  17. IMDISP - INTERACTIVE IMAGE DISPLAY PROGRAM

    Science.gov (United States)

    Martin, M. D.

    1994-01-01

    screen at once, the image can be "subsampled." For example, if the image were subsampled by a factor of 2, every other pixel from every other line would be displayed, starting from the upper left corner of the image. Any positive integer may be used for subsampling. The user may produce a histogram of an image file, which is a graph showing the number of pixels per DN value, or per range of DN values, for the entire image. IMDISP can also plot the DN value versus pixels along a line between two points on the image. The user can "stretch" or increase the contrast of an image by specifying low and high DN values; all pixels with values lower than the specified "low" will then become black, and all pixels higher than the specified "high" value will become white. Pixels between the low and high values will be evenly shaded between black and white. IMDISP is written in a modular form to make it easy to change it to work with different display devices or on other computers. The code can also be adapted for use in other application programs. There are device dependent image display modules, general image display subroutines, image I/O routines, and image label and command line parsing routines. The IMDISP system is written in C-language (94%) and Assembler (6%). It was implemented on an IBM PC with the MS DOS 3.21 operating system. IMDISP has a memory requirement of about 142k bytes. IMDISP was developed in 1989 and is a copyrighted work with all copyright vested in NASA. Additional planetary images can be obtained from the National Space Science Data Center at (301) 286-6695.

  18. Liquid crystal display

    International Nuclear Information System (INIS)

    Takami, K.

    1981-01-01

    An improved liquid crystal display device is described which can display letters, numerals and other necessary patterns in the night time using a minimized amount of radioactive material. To achieve this a self-luminous light source is placed in a limited region corresponding to a specific display area. (U.K.)

  19. INFORMATION DISPLAY: CONSIDERATIONS FOR DESIGNING COMPUTER-BASED DISPLAY SYSTEMS

    International Nuclear Information System (INIS)

    O'HARA, J.M.; PIRUS, D.; BELTRATCCHI, L.

    2004-01-01

    This paper discussed the presentation of information in computer-based control rooms. Issues associated with the typical displays currently in use are discussed. It is concluded that these displays should be augmented with new displays designed to better meet the information needs of plant personnel and to minimize the need for interface management tasks (the activities personnel have to do to access and organize the information they need). Several approaches to information design are discussed, specifically addressing: (1) monitoring, detection, and situation assessment; (2) routine task performance; and (3) teamwork, crew coordination, collaborative work

  20. Indoor Tanning Dependence in Young Adult Women.

    Science.gov (United States)

    Mays, Darren; Atkins, Michael B; Ahn, Jaeil; Tercyak, Kenneth P

    2017-11-01

    Background: There is mounting evidence that young people can develop a dependence on indoor tanning, but research on factors associated with indoor tanning dependence remains limited. Methods: This cross-sectional study investigated factors associated with indoor tanning dependence in a community sample of 389 non-Hispanic white young adult women ages 18 to 30 who had indoor tanned ≥1 time in the past year. Participants completed measures of indoor tanning dependence, including the modified CAGE and modified Diagnostic and Statistical Manual for Mental Disorders-IV psychiatric screening assessments, indoor tanning behavior and beliefs, and behavioral and psychiatric comorbidity. Results: Overall, 22.6% of the sample screened positive for indoor tanning dependence. In multivariable analyses, indoor tanning dependence was associated with younger age of indoor tanning initiation [adjusted odds ratio (aOR) = 0.79; P = 0.017], indoor tanning ≥20 times in the past year (aOR = 3.03; P = 0.015), stronger beliefs about the benefits of tanning (aOR = 2.15; P = 0.004), greater perceived susceptibility to indoor tanning risks (aOR = 2.72; P tanning dependence among young, non-Hispanic white women is associated with behaviors that increase the risk of skin cancer, beliefs favoring the perceived benefits of tanning, and comorbid risks such as stronger beliefs about physical appearance and depressed mood. Impact: Comprehensive skin cancer prevention efforts should address indoor tanning dependence among young women and its leading risk factors. Cancer Epidemiol Biomarkers Prev; 26(11); 1636-43. ©2017 AACR . ©2017 American Association for Cancer Research.

  1. Bell inequalities stronger than the Clauser-Horne-Shimony-Holt inequality for three-level isotropic states

    International Nuclear Information System (INIS)

    Ito, Tsuyoshi; Imai, Hiroshi; Avis, David

    2006-01-01

    We show that some two-party Bell inequalities with two-valued observables are stronger than the CHSH inequality for 3x3 isotropic states in the sense that they are violated by some isotropic states in the 3x3 system that do not violate the CHSH inequality. These Bell inequalities are obtained by applying triangular elimination to the list of known facet inequalities of the cut polytope on nine points. This gives a partial solution to an open problem posed by Collins and Gisin. The results of numerical optimization suggest that they are candidates for being stronger than the I 3322 Bell inequality for 3x3 isotropic states. On the other hand, we found no Bell inequalities stronger than the CHSH inequality for 2x2 isotropic states. In addition, we illustrate an inclusion relation among some Bell inequalities derived by triangular elimination

  2. Myg1-deficient mice display alterations in stress-induced responses and reduction of sex-dependent behavioural differences.

    Science.gov (United States)

    Philips, Mari-Anne; Abramov, Urho; Lilleväli, Kersti; Luuk, Hendrik; Kurrikoff, Kaido; Raud, Sirli; Plaas, Mario; Innos, Jürgen; Puussaar, Triinu; Kõks, Sulev; Vasar, Eero

    2010-02-11

    Myg1 (Melanocyte proliferating gene 1) is a highly conserved and ubiquitously expressed gene, which encodes a protein with mitochondrial and nuclear localization. In the current study we demonstrate a gradual decline of Myg1 expression during the postnatal development of the mouse brain that suggests relevance for Myg1 in developmental processes. To study the effects of Myg1 loss-of-function, we created Myg1-deficient (-/-) mice by displacing the entire coding sequence of the gene. Initial phenotyping, covering a multitude of behavioural, cognitive, neurological, physiological and stress-related responses, revealed that homozygous Myg1 (-/-) mice are vital, fertile and display no gross abnormalities. Myg1 (-/-) mice showed an inconsistent pattern of altered anxiety-like behaviour in different tests. The plus-maze and social interaction tests revealed that male Myg1 (-/-) mice were significantly less anxious than their wild-type littermates; female (-/-) mice showed increased anxiety in the locomotor activity arena. Restraint-stress significantly reduced the expression of the Myg1 gene in the prefrontal cortex of female wild-type mice and restrained female (-/-) mice showed a blunted corticosterone response, suggesting involvement of Myg1 in stress-induced responses. The main finding of the present study was that Myg1 invalidation decreases several behavioural differences between male and female animals that were obvious in wild-type mice, indicating that Myg1 contributes to the expression of sex-dependent behavioural differences in mice. Taken together, we provide evidence for the involvement of Myg1 in anxiety- and stress-related responses and suggest that Myg1 contributes to the expression of sex-dependent behavioural differences.

  3. Painting Reproductions on Display

    Directory of Open Access Journals (Sweden)

    Joanna Iranowska

    2017-09-01

    Full Text Available Paintings in museums might occasionally be replaced by a photoprint mimicking the original. This article is an investigation of what constitutes a good reproduction of an artwork (oil painting that is meant to be displayed. The article discusses what the usefulness of reproductions depends on, applying the Valuation Studies approach, which means the primary concern is with the practice of valuing itself. In other words, the study focuses on how museum experts evaluate reproduc-tions of oil paintings. The article analyses three cases of displaying digitally prin-ted copies of Edvard Munch's oil paintings between 2013 and 2015 in the Munch Museum and in the National Gallery in Oslo. The study is based on a series of semi-structured interviews with the experts, working at and for the museums, that were involved in producing and exhibiting of the photoprints: curators, con-servators, museum educators, and external manufacturers. The interviews were grouped into five clusters, which I have chosen to call registers of valuing following Frank Heuts and Annemarie Mol (2013. The described valuation practices have to do with delivering experiences to the public, obtaining mimetic resemblance, solving ethical aspects, exhibitions' budget, and last but not least, with the time perspective.

  4. Predatory blue crabs induce stronger nonconsumptive effects in eastern oysters Crassostrea virginica than scavenging blue crabs

    Directory of Open Access Journals (Sweden)

    Avery E. Scherer

    2017-02-01

    Full Text Available By influencing critical prey traits such as foraging or habitat selection, predators can affect entire ecosystems, but the nature of cues that trigger prey reactions to predators are not well understood. Predators may scavenge to supplement their energetic needs and scavenging frequency may vary among individuals within a species due to preferences and prey availability. Yet prey reactions to consumers that are primarily scavengers versus those that are active foragers have not been investigated, even though variation in prey reactions to scavengers or predators might influence cascading nonconsumptive effects in food webs. Oysters Crassostrea virginica react to crab predators by growing stronger shells. We exposed oysters to exudates from crabs fed live oysters or fed aged oyster tissue to simulate scavenging, and to controls without crab cues. Oysters grew stronger shells when exposed to either crab exudate, but their shells were significantly stronger when crabs were fed live oysters. The stronger response to predators than scavengers could be due to inherent differences in diet cues representative of reduced risk in the presence of scavengers or to degradation of conspecific alarm cues in aged treatments, which may mask risk from potential predators subsisting by scavenging.

  5. 特质应对与展现规则对情绪劳动的影响%Effects of Trait Coping Styles and Emotional Display Rules on Emotional Labor Strategies

    Institute of Scientific and Technical Information of China (English)

    林川; 黄敏儿

    2011-01-01

    more emotional labor in the speech. Subjective emotional experiences at three points (e.g., before and after the memory task, after the speech) were recorded accordingly. Emotional labor strategies in speech were reported after the speech. MANOVA statistic method was employed to test the effects of the experiment. The results indicated: (1) Comparing to Negative Coping group, Positive Coping group reported stronger deep acting, and less surface acting just under condition of Positive Display Rule. (2) Comparing to control group, Positive and Negative Display Rule Groups reported stronger emotional labor both deep and surface acting. Further more, Positive Coping Group reported less surface acting under Positive rule, and Negative Coping Group reported more surface acting under Positive Rule. (3) Stronger positive emotions in Trait Positive Coping Group and stronger negative emotions in Trait Negative Coping may explain well on the main effect of the Traits and the interacting effects of The Traits and the Rules upon emotional labor strategies. The study suggests that Trait Positive Coping Style may be considered as an adaptive trait for working in emotional-labor-intense industries setting. Positive display rule fits well with the people of higher in Trait Positive Coping Style and negative display rule fits well with the people of higher in Trait Negative Coping Style. The study may be applied in working of personnel management (e.g., recruitment and psychological training) in emotional-labor- intense industry settings.

  6. When surging seas meet stronger rain: Nuclear techniques in flood management

    International Nuclear Information System (INIS)

    Quevenco, Rodolfo

    2015-01-01

    Unusually high rainfall in many parts of the world is a result of climate change, scientists say. Since warmer air can hold more water, the rationale goes, increased temperatures will increase the chances of stronger rainfall events. And when surging seas combine with stronger rain, the outcome is almost certain: floods. Floods are the most frequently occurring natural disasters, and south-east Asia is particularly vulnerable. Climate change and variability are expected to bring about increased typhoon activities, rising sea levels and off-season monsoon rains in southeast Asia and other regions. These can cause devastating floods in countries like Cambodia, Laos, Pakistan, the Philippines, Thailand and Viet Nam. For the residents of these countries who have survived the ravages of major floods, the road to recovery can be long and arduous. As the flood water recedes, they have to contend with new forms of flood: floods of concern and worries as to how to rebuild their houses, their lives and their cities. Governments, too, face huge challenges in rebuilding roads, public buildings, infrastructure and natural resources destroyed or polluted by the flood.

  7. Density dependence of relaxation dynamics in glass formers, and ...

    Indian Academy of Sciences (India)

    Anshul D S Parmar

    formers, we study the variation of relaxation dynamics with density, rather than temperature, as a control ... stronger behaviour, the use of scaled variables involving temperature and ... of the temperature dependence of B as written defines.

  8. Liquid Crystal Airborne Display

    Science.gov (United States)

    1977-08-01

    Cum.nings, J. P., et al., Properties and Limitations oe Liquid Crystals for Aircraft Displays, Honeywell Corporate Researc ."I Center, Final Report HR-72...basic module could be used to build displays for both the commercial and military! 157- marhecs, and so would establi sh a broad and sizable market ... market for the display becomes a reality; therein lies, f TABLE 16 THE COURSE OF FUTURE DISPLAY DEVELOPMENT Today 1976-77 1980 1985 Display Size 2" 1 3.2

  9. Evaluation of force-torque displays for use with space station telerobotic activities

    Science.gov (United States)

    Hendrich, Robert C.; Bierschwale, John M.; Manahan, Meera K.; Stuart, Mark A.; Legendre, A. Jay

    1992-01-01

    Recent experiments which addressed Space Station remote manipulation tasks found that tactile force feedback (reflecting forces and torques encountered at the end-effector through the manipulator hand controller) does not improve performance significantly. Subjective response from astronaut and non-astronaut test subjects indicated that force information, provided visually, could be useful. No research exists which specifically investigates methods of presenting force-torque information visually. This experiment was designed to evaluate seven different visual force-torque displays which were found in an informal telephone survey. The displays were prototyped in the HyperCard programming environment. In a within-subjects experiment, 14 subjects nullified forces and torques presented statically, using response buttons located at the bottom of the screen. Dependent measures included questionnaire data, errors, and response time. Subjective data generally demonstrate that subjects rated variations of pseudo-perspective displays consistently better than bar graph and digital displays. Subjects commented that the bar graph and digital displays could be used, but were not compatible with using hand controllers. Quantitative data show similar trends to the subjective data, except that the bar graph and digital displays both provided good performance, perhaps do to the mapping of response buttons to display elements. Results indicate that for this set of displays, the pseudo-perspective displays generally represent a more intuitive format for presenting force-torque information.

  10. JAVA Stereo Display Toolkit

    Science.gov (United States)

    Edmonds, Karina

    2008-01-01

    This toolkit provides a common interface for displaying graphical user interface (GUI) components in stereo using either specialized stereo display hardware (e.g., liquid crystal shutter or polarized glasses) or anaglyph display (red/blue glasses) on standard workstation displays. An application using this toolkit will work without modification in either environment, allowing stereo software to reach a wider audience without sacrificing high-quality display on dedicated hardware. The toolkit is written in Java for use with the Swing GUI Toolkit and has cross-platform compatibility. It hooks into the graphics system, allowing any standard Swing component to be displayed in stereo. It uses the OpenGL graphics library to control the stereo hardware and to perform the rendering. It also supports anaglyph and special stereo hardware using the same API (application-program interface), and has the ability to simulate color stereo in anaglyph mode by combining the red band of the left image with the green/blue bands of the right image. This is a low-level toolkit that accomplishes simply the display of components (including the JadeDisplay image display component). It does not include higher-level functions such as disparity adjustment, 3D cursor, or overlays all of which can be built using this toolkit.

  11. Latest development of display technologies

    International Nuclear Information System (INIS)

    Gao Hong-Yue; Yao Qiu-Xiang; Liu Pan; Zheng Zhi-Qiang; Liu Ji-Cheng; Zheng Hua-Dong; Zeng Chao; Yu Ying-Jie; Sun Tao; Zeng Zhen-Xiang

    2016-01-01

    In this review we will focus on recent progress in the field of two-dimensional (2D) and three-dimensional (3D) display technologies. We present the current display materials and their applications, including organic light-emitting diodes (OLEDs), flexible OLEDs quantum dot light emitting diodes (QLEDs), active-matrix organic light emitting diodes (AMOLEDs), electronic paper (E-paper), curved displays, stereoscopic 3D displays, volumetric 3D displays, light field 3D displays, and holographic 3D displays. Conventional 2D display devices, such as liquid crystal devices (LCDs) often result in ambiguity in high-dimensional data images because of lacking true depth information. This review thus provides a detailed description of 3D display technologies. (topical review)

  12. Adaptation of Control Center Software to Commerical Real-Time Display Applications

    Science.gov (United States)

    Collier, Mark D.

    1994-01-01

    NASA-Marshall Space Flight Center (MSFC) is currently developing an enhanced Huntsville Operation Support Center (HOSC) system designed to support multiple spacecraft missions. The Enhanced HOSC is based upon a distributed computing architecture using graphic workstation hardware and industry standard software including POSIX, X Windows, Motif, TCP/IP, and ANSI C. Southwest Research Institute (SwRI) is currently developing a prototype of the Display Services application for this system. Display Services provides the capability to generate and operate real-time data-driven graphic displays. This prototype is a highly functional application designed to allow system end users to easily generate complex data-driven displays. The prototype is easy to use, flexible, highly functional, and portable. Although this prototype is being developed for NASA-MSFC, the general-purpose real-time display capability can be reused in similar mission and process control environments. This includes any environment depending heavily upon real-time data acquisition and display. Reuse of the prototype will be a straight-forward transition because the prototype is portable, is designed to add new display types easily, has a user interface which is separated from the application code, and is very independent of the specifics of NASA-MSFC's system. Reuse of this prototype in other environments is a excellent alternative to creation of a new custom application, or for environments with a large number of users, to purchasing a COTS package.

  13. Displays and simulators

    Science.gov (United States)

    Mohon, N.

    A 'simulator' is defined as a machine which imitates the behavior of a real system in a very precise manner. The major components of a simulator and their interaction are outlined in brief form, taking into account the major components of an aircraft flight simulator. Particular attention is given to the visual display portion of the simulator, the basic components of the display, their interactions, and their characteristics. Real image displays are considered along with virtual image displays, and image generators. Attention is given to an advanced simulator for pilot training, a holographic pancake window, a scan laser image generator, the construction of an infrared target simulator, and the Apollo Command Module Simulator.

  14. The polar 2e/12c bond in phenalenyl-azaphenalenyl hetero-dimers: Stronger stacking interaction and fascinating interlayer charge transfer

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Rong-Lin; Li, Zhi-Ru, E-mail: hlxu@nenu.edu.cn, E-mail: lzr@jlu.edu.cn [Institute of Theoretical Chemistry, Jilin University, Changchun 130023 (China); Xu, Hong-Liang, E-mail: hlxu@nenu.edu.cn, E-mail: lzr@jlu.edu.cn [Institute of Functional Material Chemistry, Faculty of Chemistry, Northeast Normal University, Changchun, Jilin 130024 (China)

    2016-08-07

    An increasing number of chemists have focused on the two-electron/multicenter bond (2e/mc) that was first introduced to interpret the bonding mechanism of radical dimers. Herein, we report the polar two-electron/twelve center (2e/12c) bonding character in a series of phenalenyl-azaphenalenyl radical hetero-dimers. Interestingly, the bonding energy of weaker polar hetero-dimer (P-TAP) is dominated by the overlap of the two different singly occupied molecular orbital of radicals, while that of stronger polar hetero-dimer (P-HAP) is dominated by the electrostatic attraction. Results show that the difference between the electronegativity of the monomers plays a prominent role in the essential attribution of the polar 2e/12c bond. Correspondingly, a stronger stacking interaction in the hetero-dimer could be effectively achieved by increasing the difference of nitrogen atoms number between the monomers. It is worthy of note that an interesting interlayer charge transfer character is induced in the polar hetero-dimers, which is dependent on the difference between the electronegativity of the monomers. It is our expectation that the new knowledge about the bonding nature of radical hetero-dimers might provide important information for designing radical based functional materials with various applications.

  15. Displays enabling mobile multimedia

    Science.gov (United States)

    Kimmel, Jyrki

    2007-02-01

    With the rapid advances in telecommunications networks, mobile multimedia delivery to handsets is now a reality. While a truly immersive multimedia experience is still far ahead in the mobile world, significant advances have been made in the constituent audio-visual technologies to make this become possible. One of the critical components in multimedia delivery is the mobile handset display. While such alternatives as headset-style near-to-eye displays, autostereoscopic displays, mini-projectors, and roll-out flexible displays can deliver either a larger virtual screen size than the pocketable dimensions of the mobile device can offer, or an added degree of immersion by adding the illusion of the third dimension in the viewing experience, there are still challenges in the full deployment of such displays in real-life mobile communication terminals. Meanwhile, direct-view display technologies have developed steadily, and can provide a development platform for an even better viewing experience for multimedia in the near future. The paper presents an overview of the mobile display technology space with an emphasis on the advances and potential in developing direct-view displays further to meet the goal of enabling multimedia in the mobile domain.

  16. On Integrity of Flexible Displays

    Science.gov (United States)

    Bouten, Piet C. P.

    Nowadays two display types are dominant in the display market: the bulky cathode ray tube (CRT) and liquid crystal displays (LCD). Both types use glass as substrate material. The LCD display is the dominant player for mobile applications, in for instance mobile phones and portable computers. In the development of displays and their applications a clear interest exists to replace the rigid rectangular display cells by free-shaped, curved or even roll-up cells. These types of applications require flexible displays.

  17. Mechanical Stability of Flexible Graphene-Based Displays.

    Science.gov (United States)

    Anagnostopoulos, George; Pappas, Panagiotis-Nektarios; Li, Zheling; Kinloch, Ian A; Young, Robert J; Novoselov, Kostya S; Lu, Ching Yu; Pugno, Nicola; Parthenios, John; Galiotis, Costas; Papagelis, Konstantinos

    2016-08-31

    The mechanical behavior of a prototype touch panel display, which consists of two layers of CVD graphene embedded into PET films, is investigated in tension and under contact-stress dynamic loading. In both cases, laser Raman spectroscopy was employed to assess the stress transfer efficiency of the embedded graphene layers. The tensile behavior was found to be governed by the "island-like" microstructure of the CVD graphene, and the stress transfer efficiency was dependent on the size of graphene "islands" but also on the yielding behavior of PET at relatively high strains. Finally, the fatigue tests, which simulate real operation conditions, showed that the maximum temperature gradient developed at the point of "finger" contact after 80 000 cycles does not exceed the glass transition temperature of the PET matrix. The effect of these results on future product development and the design of new graphene-based displays are discussed.

  18. MCNP simulations of a glass display used in a mobile phone as an accident dosimeter

    International Nuclear Information System (INIS)

    Discher, Michael; Hiller, Mauritius; Woda, Clemens

    2015-01-01

    It has been demonstrated that glass display of mobile phones can be used as a device for accident dosimetry. Published studies concentrated on the experimental investigation of parts of the glass display. In the work presented here, the experimental results are compared with results of radiation transport calculations using the Monte Carlo code MCNP5. An experimental setup of an irradiation of an extracted glass display is simulated. The simulation is then extended to a simulation of a modern day mobile phone consisting of all major parts. Simulations are performed for various irradiation conditions and different geometric and material properties. The results of the simulation show a good agreement with the experiments for an extracted glass sample as well as for an actual modern mobile phone. The glass display is exposed to radiation in various angular and energy distributions. Simulated results were compared to experimentally determined results. The effects of the irradiation condition on the photon energy dependence were investigated and variations in the material constants of the display glass composition were discussed. This work affirms the usability of a mobile phone as a versatile and flexible accident radiation detector. - Highlights: • Simulations of a modern day mobile phone using MCNP are carried out. • Results of the simulation show a good agreement with the experiments. • Photon energy dependence and angular response for display glass are verified

  19. Optical Addressing of Multi-Colour Photochromic Material Mixture for Volumetric Display

    Science.gov (United States)

    Hirayama, Ryuji; Shiraki, Atsushi; Naruse, Makoto; Nakamura, Shinichiro; Nakayama, Hirotaka; Kakue, Takashi; Shimobaba, Tomoyoshi; Ito, Tomoyoshi

    2016-08-01

    This is the first study to demonstrate that colour transformations in the volume of a photochromic material (PM) are induced at the intersections of two control light channels, one controlling PM colouration and the other controlling decolouration. Thus, PM colouration is induced by position selectivity, and therefore, a dynamic volumetric display may be realised using these two control lights. Moreover, a mixture of multiple PM types with different absorption properties exhibits different colours depending on the control light spectrum. Particularly, the spectrum management of the control light allows colour-selective colouration besides position selectivity. Therefore, a PM-based, full-colour volumetric display is realised. We experimentally construct a mixture of two PM types and validate the operating principles of such a volumetric display system. Our system is constructed simply by mixing multiple PM types; therefore, the display hardware structure is extremely simple, and the minimum size of a volume element can be as small as the size of a molecule. Volumetric displays can provide natural three-dimensional (3D) perception; therefore, the potential uses of our system include high-definition 3D visualisation for medical applications, architectural design, human-computer interactions, advertising, and entertainment.

  20. Augmenting digital displays with computation

    Science.gov (United States)

    Liu, Jing

    As we inevitably step deeper and deeper into a world connected via the Internet, more and more information will be exchanged digitally. Displays are the interface between digital information and each individual. Naturally, one fundamental goal of displays is to reproduce information as realistically as possible since humans still care a lot about what happens in the real world. Human eyes are the receiving end of such information exchange; therefore it is impossible to study displays without studying the human visual system. In fact, the design of displays is rather closely coupled with what human eyes are capable of perceiving. For example, we are less interested in building displays that emit light in the invisible spectrum. This dissertation explores how we can augment displays with computation, which takes both display hardware and the human visual system into consideration. Four novel projects on display technologies are included in this dissertation: First, we propose a software-based approach to driving multiview autostereoscopic displays. Our display algorithm can dynamically assign views to hardware display zones based on multiple observers' current head positions, substantially reducing crosstalk and stereo inversion. Second, we present a dense projector array that creates a seamless 3D viewing experience for multiple viewers. We smoothly interpolate the set of viewer heights and distances on a per-vertex basis across the arrays field of view, reducing image distortion, crosstalk, and artifacts from tracking errors. Third, we propose a method for high dynamic range display calibration that takes into account the variation of the chrominance error over luminance. We propose a data structure for enabling efficient representation and querying of the calibration function, which also allows user-guided balancing between memory consumption and the amount of computation. Fourth, we present user studies that demonstrate that the ˜ 60 Hz critical flicker fusion

  1. : Light Steering Projection Systems and Attributes for HDR Displays

    KAUST Repository

    Damberg, Gerwin

    2017-06-02

    New light steering projectors in cinema form images by moving light away from dark regions into bright areas of an image. In these systems, the peak luminance of small features can far exceed full screen white luminance. In traditional projectors where light is filtered or blocked in order to give shades of gray (or colors), the peak luminance is fixed. The luminance of chromatic features benefit in the same way as white features, and chromatic image details can be reproduced at high brightness leading to a much wider overall color gamut coverage than previously possible. Projectors of this capability are desired by the creative community to aid in and enhance storytelling. Furthermore, reduced light source power requirements of light steering projectors provide additional economic and environmental benefits. While the dependency of peak luminance level on (bright) image feature size is new in the digital cinema space, display technologies with identical characteristics such as OLED, LED LCD and Plasma TVs are well established in the home. Similarly, direct view LED walls are popular in events, advertising and architectural markets. To enable consistent color reproduction across devices in today’s content production pipelines, models that describe modern projectors and display attributes need to evolve together with HDR standards and available metadata. This paper is a first step towards rethinking legacy display descriptors such as contrast, peak luminance and color primaries in light of new display technology. We first summarize recent progress in the field of light steering projectors in cinema and then, based on new projector and existing display characteristics propose the inclusion of two simple display attributes: Maximum Average Luminance and Peak (Color) Primary Luminance. We show that the proposed attributes allow a better prediction of content reproducibility on HDR displays. To validate this assertion, we test professional content on a commercial HDR

  2. Display of adenoregulin with a novel Pichia pastoris cell surface display system.

    Science.gov (United States)

    Ren, Ren; Jiang, Zhengbing; Liu, Meiyun; Tao, Xinyi; Ma, Yushu; Wei, Dongzhi

    2007-02-01

    Two Pichia pastoris cell surface display vectors were constructed. The vectors consisted of the flocculation functional domain of Flo1p with its own secretion signal sequence or the alpha-factor secretion signal sequence, a polyhistidine (6xHis) tag for detection, an enterokinase recognition site, and the insertion sites for target proteins. Adenoregulin (ADR) is a 33-amino-acid antimicrobial peptide isolated from Phyllomedusa bicolor skin. The ADR was expressed and displayed on the Pichia pastoris KM71 cell surface with the system reported. The displayed recombinant ADR fusion protein was detected by fluorescence microscopy and confocal laser scanning microscopy (CLSM). The antimicrobial activity of the recombinant adenoregulin was detected after proteolytic cleavage of the fusion protein on cell surface. The validity of the Pichia pastoris cell surface display vectors was proved by the displayed ADR.

  3. Mechanical Stability of Flexible Graphene-Based Displays

    Science.gov (United States)

    2016-01-01

    The mechanical behavior of a prototype touch panel display, which consists of two layers of CVD graphene embedded into PET films, is investigated in tension and under contact-stress dynamic loading. In both cases, laser Raman spectroscopy was employed to assess the stress transfer efficiency of the embedded graphene layers. The tensile behavior was found to be governed by the “island-like” microstructure of the CVD graphene, and the stress transfer efficiency was dependent on the size of graphene “islands” but also on the yielding behavior of PET at relatively high strains. Finally, the fatigue tests, which simulate real operation conditions, showed that the maximum temperature gradient developed at the point of “finger” contact after 80 000 cycles does not exceed the glass transition temperature of the PET matrix. The effect of these results on future product development and the design of new graphene-based displays are discussed. PMID:27494211

  4. Solvent-dependent fluorescence enhancement and piezochromism of a carbazole-substituted naphthopyran

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Lihui; Wang, Aixia [Faculty of Chemistry, Northeast Normal University, Changchun 130024 (China); Wang, Guang, E-mail: wangg923@nenu.edu.cn [Faculty of Chemistry, Northeast Normal University, Changchun 130024 (China); Munyentwari, Alexis [Faculty of Chemistry, Northeast Normal University, Changchun 130024 (China); Zhou, Yihan, E-mail: yhzhou@ciac.ac.cn [National Analytical Research Center of Electrochemistry and Spectroscopy, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China)

    2015-09-15

    A novel carbazole-substituted naphthopyran, 3,3-bis-(4-carbazolylphenyl)-[3H]-naphtho[2,1-b]pyran (CzNP) was designed and synthesized. The new compound exhibited normal photochromism in dichloromethane solution and the UV irradiation did not influence its fluorescence. On the contrary, the fluorescence of CzNP in N,N-dimethylformamide (DMF) was intensively enhanced to 29 times after 60 min of the UV irradiation and this enhanced fluorescence can be quenched by addition of triethylamine (TEA). The study of enhanced extent of fluorescence of CzNP in solvents with different polarities and in mixed solvents demonstrated that the enhanced fluorescence is dependent on the polarity of solvents. The larger the polarity of solvent was, the stronger was the fluorescence of CzNP. CzNP also exhibited piezochromic performance and the pressure led to the cleavage of the C–O bond of pyran ring. - Highlights: • A carbazole-substituted photochromic naphthopyran was designed and synthesized. • The fluorescence was enhanced under the existence of DMF and UV irradiation. • The polarity of solvent was the dominating factor to affect the fluorescence. • The new compound also displayed piezochromic performance.

  5. An experimental and theoretical study of new phosphors for full color field emission displays

    Science.gov (United States)

    Zhang, Fu-Li

    An in depth study is reported of the cathodoluminescent (CL) properties of three new highly efficiency blue phosphors for field emission display (FED) applications doped with fast activators. The superior performance of a new Eu-doped green SrGa2S4 will also be reported. This work addresses four main topics: (1) a detailed study of the dependence of the luminescent intensity on activator concentration, as a function of electron beam voltage and current density; (2) the optical properties of thew phosphors and the development of a CL efficiency characterization technique using a critical screen weight method, which can obtain maximum light output and improve measurement accuracy; (3) understanding the low voltage CL mechanism associated with nanocrystal size by developing a thin film and disk model based on transportation theory and experimental results; (4) Development of a comprehensive evaluation method of red, green, and blue (RGB) phosphors for full color displays by calculation of luminance ratios, required luminance, and measurements of spectra, efficiency and saturation behavior. For FEDs which combine the best properties of CRT and flat panel displays, the development of efficient phosphors at low voltages and high current densities is shown to be critical to meet the luminance and power requirement demands for portable displays. Of particular importance is the need for a good blue phosphor, and to understand the dependence of the CL efficiency on nanocrystal size, penetration depth, diffusion length and surface recombination rate. This has been obtained from the thin film and disk models and fits to experiment. Comparisons between full color phosphor sets show that the performance of a display can vary by over a factor of three depending on the choice of the RGB set. Other factors that are important for optimizing the performance of FED phosphors are reviewed.

  6. Flat panel display - Impurity doping technology for flat panel displays

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Toshiharu [Advanced Technology Planning, Sumitomo Eaton Nova Corporation, SBS Tower 9F, 10-1, Yoga 4-chome, Setagaya-ku, 158-0097 Tokyo (Japan)]. E-mail: suzuki_tsh@senova.co.jp

    2005-08-01

    Features of the flat panel displays (FPDs) such as liquid crystal display (LCD) and organic light emitting diode (OLED) display, etc. using low temperature poly-Si (LTPS) thin film transistors (TFTs) are briefly reviewed comparing with other FPDs. The requirements for fabricating TFTs used for high performance FPDs and system on glass (SoG) are addressed. This paper focuses on the impurity doping technology, which is one of the key technologies together with crystallization by laser annealing, formation of high quality gate insulator and gate-insulator/poly-Si interface. The issues to be solved in impurity doping technology for state of the art and future TFTs are clarified.

  7. Flat panel display - Impurity doping technology for flat panel displays

    International Nuclear Information System (INIS)

    Suzuki, Toshiharu

    2005-01-01

    Features of the flat panel displays (FPDs) such as liquid crystal display (LCD) and organic light emitting diode (OLED) display, etc. using low temperature poly-Si (LTPS) thin film transistors (TFTs) are briefly reviewed comparing with other FPDs. The requirements for fabricating TFTs used for high performance FPDs and system on glass (SoG) are addressed. This paper focuses on the impurity doping technology, which is one of the key technologies together with crystallization by laser annealing, formation of high quality gate insulator and gate-insulator/poly-Si interface. The issues to be solved in impurity doping technology for state of the art and future TFTs are clarified

  8. Handbook of Visual Display Technology

    CERN Document Server

    Cranton, Wayne; Fihn, Mark

    2012-01-01

    The Handbook of Visual Display Technology is a unique work offering a comprehensive description of the science, technology, economic and human interface factors associated with the displays industry. An invaluable compilation of information, the Handbook will serve as a single reference source with expert contributions from over 150 international display professionals and academic researchers. All classes of display device are covered including LCDs, reflective displays, flexible solutions and emissive devices such as OLEDs and plasma displays, with discussion of established principles, emergent technologies, and particular areas of application. The wide-ranging content also encompasses the fundamental science of light and vision, image manipulation, core materials and processing techniques, display driving and metrology.

  9. Polymer Dispersed Liquid Crystal Displays

    Science.gov (United States)

    Doane, J. William

    The following sections are included: * INTRODUCTION AND HISTORICAL DEVELOPMENT * PDLC MATERIALS PREPARATION * Polymerization induced phase separation (PIPS) * Thermally induced phase separation (TIPS) * Solvent induced phase separation (SIPS) * Encapsulation (NCAP) * RESPONSE VOLTAGE * Dielectric and resistive effects * Radial configuration * Bipolar configuration * Other director configurations * RESPONSE TIME * DISPLAY CONTRAST * Light scattering and index matching * Incorporation of dyes * Contrast measurements * PDLC DISPLAY DEVICES AND INNOVATIONS * Reflective direct view displays * Large-scale, flexible displays * Switchable windows * Projection displays * High definition spatial light modulator * Haze-free PDLC shutters: wide angle view displays * ENVIRONMENTAL STABILITY * ACKNOWLEDGEMENTS * REFERENCES

  10. Information rich display design

    International Nuclear Information System (INIS)

    Welch, Robin; Braseth, Alf Ove; Veland, Oeystein

    2004-01-01

    This paper presents the concept Information Rich Displays. The purpose of Information Rich Displays (IRDs) is to condensate prevailing information in process displays in such a way that each display format (picture) contains more relevant information for the user. Compared to traditional process control displays, this new concept allows the operator to attain key information at a glance and at the same time allows for improved monitoring of larger portions of the process. This again allows for reduced navigation between both process and trend displays and ease the cognitive demand on the operator. This concept has been created while working on designing display prototypes for the offshore petroleum production facilities of tomorrow. Offshore installations basically consist of wells, separation trains (where oil, gas and water are separated from each other), an oil tax measurement system (where oil quality is measured and the pressure increased to allow for export), gas compression (compression of gas for export) and utility systems (water treatment, chemical systems etc.). This means that an offshore control room operator has to deal with a complex process that comprises several functionally different systems. The need for a new approach to offshore display format design is in particular based on shortcomings in today's designs related to the keyhole effect, where the display format only reveals a fraction of the whole process. Furthermore, the upcoming introduction of larger off- and on-shore operation centres will increase the size and complexity of the operators' work domain. In the light of the increased demands on the operator, the proposed IRDs aim to counter the negative effects this may have on the workload. In this work we have attempted to classify the wide range of different roles an operator can have in different situations. The information content and amount being presented to the operator in a display should be viewed in context of the roles the

  11. Photophysical study of a cyclophane displaying intramolecular exciplex emission

    International Nuclear Information System (INIS)

    Galindo, Francisco; Isabel Burguete, M.; Luis, Santiago V.

    2004-01-01

    The photophysical behavior of cyclophane 1, comprised by two L-valine units and one naphthalene ring, has been studied. It displays exciplex (EX) emission with a maximum in the range 390-460 nm, depending on solvent polarity. From this dependence a dipole moment of 19.4 D for the excited charge-transfer state has been calculated. Fluorescence quantum yields in organic media ranging from 0.012 to 0.038 have been measured. This phenomenon has been interpreted taking into account the rigidity imposed by the cyclophane framework which could pre-orient the donor and the acceptor subunits for a favorable interaction

  12. Photophysical study of a cyclophane displaying intramolecular exciplex emission

    Energy Technology Data Exchange (ETDEWEB)

    Galindo, Francisco; Isabel Burguete, M.; Luis, Santiago V

    2004-07-12

    The photophysical behavior of cyclophane 1, comprised by two L-valine units and one naphthalene ring, has been studied. It displays exciplex (EX) emission with a maximum in the range 390-460 nm, depending on solvent polarity. From this dependence a dipole moment of 19.4 D for the excited charge-transfer state has been calculated. Fluorescence quantum yields in organic media ranging from 0.012 to 0.038 have been measured. This phenomenon has been interpreted taking into account the rigidity imposed by the cyclophane framework which could pre-orient the donor and the acceptor subunits for a favorable interaction.

  13. BUILDING STRONGER STATE ENERGY PARTNERSHIPS WITH THE U.S. DEPARTMENT OF ENERGY

    Energy Technology Data Exchange (ETDEWEB)

    Kate Burke

    2002-11-01

    This technical progress report includes an update of the progress during the second year of cooperative agreement DE-FC26-00NT40802, Building Stronger State Energy Partnerships with the U.S. Department of Energy. The report also describes the barriers in conduct of the effort, and our assessment of future progress and activities.

  14. Measurement techniques of LC display systems

    Science.gov (United States)

    Kosmowski, Bogdan B.; Becker, Michael E.; Neumeier, Juergen

    1993-10-01

    The strong increase of applications of liquid crystal displays in various areas (measuring, medical equipment, automotive, telecommunication, office, etc.) has forced the demand for the adequate specification of the LCDs performances. The optical, electro-optical and spectral properties of LCDs are strongly dependent on viewing direction, electrical driving conditions, illumination and temperature. All these quantities have to be precisely controlled, when one of them is varied, the resulting optical response of the object is recorded. In this paper we present measuring methods proposed for LCD panels and the computer controlled measuring system (DMS) for their evaluation.

  15. Producing EGS4 shower displays with the Unified Graphics System

    International Nuclear Information System (INIS)

    Cowan, R.F.

    1990-01-01

    The EGS4 Code System has been coupled with the SLAC Unified Graphics System in such a manner as to provide a means for displaying showers on UGS77-supported devices. This is most easily accomplished by attaching an auxiliary subprogram package (SHOWGRAF) to existing EGS4 User Codes and making use of a graphics display or a post-processor code called EGS4PL. SHOWGRAF may be used to create shower displays directly on interactive IBM 5080 color display devices, supporting three-dimensional rotations, translations, and zoom features, and providing illustration of particle types and energies by color and/or intensity. Alternatively, SHOWGRAF may be used to record a two-dimensional projection of the shower in a device-independent graphics file. The EGS4PL post-processor may then be used to convert this file into device-dependent graphics code for any UGS77-supported device. Options exist within EGS4PL that allow for two-dimensional translations and zoom, for creating line structure to indicate particle types and energies, and for optional display of particles by type. All of this is facilitated by means of the command processor EGS4PL EXEC together with new options (5080 and PDEV) with the standard EGS4IN EXEC routine for running EGS4 interactively under VM/SP. 6 refs

  16. Display of nuclear medicine imaging studies

    International Nuclear Information System (INIS)

    Singh, B.; Kataria, S.K.; Samuel, A.M.

    2002-08-01

    Nuclear medicine imaging studies involve evaluation of a large amount of image data. Digital signal processing techniques have introduced processing algorithms that increase the information content of the display. Nuclear medicine imaging studies require interactive selection of suitable form of display and pre-display processing. Static imaging study requires pre-display processing to detect focal defects. Point operations (histogram modification) along with zoom and capability to display more than one image in one screen is essential. This album mode of display is also applicable to dynamic, MUGA and SPECT data. Isometric display or 3-D graph of the image data is helpful in some cases e.g. point spread function, flood field data. Cine display is used on a sequence of images e.g. dynamic, MUGA and SPECT imaging studies -to assess the spatial movement of tracer with time. Following methods are used at the investigator's discretion for inspection of the 3-D object. 1) Display of orthogonal projections, 2) Display of album of user selected coronal/ sagital/ transverse orthogonal slices, 3) Display of three orthogonal slices through user selected point, 4) Display of a set of orthogonal slices generated in the user-selected volume, 5) Generation and display of 3-D shaded surface. 6) Generation of volume data and display along with the 3-D shaded surface, 7) Side by side display orthogonal slices of two 3-D objects. Displaying a set of two-dimensional slices of a 3-D reconstructed object through shows all the defects but lacks the 3-D perspective. Display of shaded surface lacks the ability to show the embedded defects. Volume display -combining the 3-D surface and gray level volume data is perhaps the best form of display. This report describes these forms of display along with the theory. (author)

  17. Display technologies for augmented reality

    Science.gov (United States)

    Lee, Byoungho; Lee, Seungjae; Jang, Changwon; Hong, Jong-Young; Li, Gang

    2018-02-01

    With the virtue of rapid progress in optics, sensors, and computer science, we are witnessing that commercial products or prototypes for augmented reality (AR) are penetrating into the consumer markets. AR is spotlighted as expected to provide much more immersive and realistic experience than ordinary displays. However, there are several barriers to be overcome for successful commercialization of AR. Here, we explore challenging and important topics for AR such as image combiners, enhancement of display performance, and focus cue reproduction. Image combiners are essential to integrate virtual images with real-world. Display performance (e.g. field of view and resolution) is important for more immersive experience and focus cue reproduction may mitigate visual fatigue caused by vergence-accommodation conflict. We also demonstrate emerging technologies to overcome these issues: index-matched anisotropic crystal lens (IMACL), retinal projection displays, and 3D display with focus cues. For image combiners, a novel optical element called IMACL provides relatively wide field of view. Retinal projection displays may enhance field of view and resolution of AR displays. Focus cues could be reconstructed via multi-layer displays and holographic displays. Experimental results of our prototypes are explained.

  18. Next generation smart window display using transparent organic display and light blocking screen.

    Science.gov (United States)

    Kim, Gyeong Woo; Lampande, Raju; Choe, Dong Cheol; Ko, Ik Jang; Park, Jin Hwan; Pode, Ramchandra; Kwon, Jang Hyuk

    2018-04-02

    Transparent organic light emitting diodes (TOLED) have widespread applications in the next-generation display devices particularly in the large size transparent window and interactive displays. Herein, we report high performance and stable attractive smart window displays using facile process. Advanced smart window display is realized by integrating the high performance light blocking screen and highly transparent white OLED panel. The full smart window display reveals a maximum transmittance as high as 64.2% at the wavelength of 600 nm and extremely good along with tunable ambient contrast ratio (171.94:1) compared to that of normal TOLED (4.54:1). Furthermore, the performance decisive light blocking screen has demonstrated an excellent optical and electrical characteristics such as i) high transmittance (85.56% at 562nm) at light-penetrating state, ii) superior absorbance (2.30 at 562nm) in light interrupting mode, iii) high optical contrast (85.50 at 562 nm), iv) high optical stability for more than 25,000 cycle of driving, v) fast switching time of 1.9 sec, and vi) low driving voltage of 1.7 V. The experimental results of smart window display are also validated using optical simulation. The proposed smart window display technology allows us to adjust the intensity of daylight entering the system quickly and conveniently.

  19. Linear perspective limitations on virtual reality and realistic displays

    Science.gov (United States)

    Temme, Leonard A.

    2007-04-01

    The visual images of the natural world, with their immediate intuitive appeal, seem like the logical gold standard for evaluating displays. After all, since photorealistic displays look so increasingly like the real world, what could be better? Part of the shortcoming of this intuitive appeal for displays is its naivete. Realism itself is full of potential illusions that we do not notice because, most of the time, realism is good enough for our everyday tasks. But when confronted with tasks that go beyond those for which our visual system has evolved, we may be blindsided. If we survive, blind to our erroneous perceptions and oblivious to our good fortune at having survived, we will not be any wiser next time. Realist displays depend on linear perspective (LP), the mathematical mapping of three dimensions onto two. Despite the fact that LP is a seductively elegant system that predicts results with defined mathematical procedures, artists do not stick to the procedures, not because they are math-phobic but because LP procedures, if followed explicitly, produce ugly, limited, and distorted images. If artists bother with formal LP procedures at all, they invariably temper the renderings by eye. The present paper discusses LP assumptions, limitations, and distortions. It provides examples of kluges to cover some of these LP shortcomings. It is important to consider the limitations of LP so that we do not let either naive assumptions or the seductive power of LP guide our thinking or expectations unrealistically as we consider its possible uses in advanced visual displays.

  20. Operation aid system upon occurrence of abnormality and display method therefor

    International Nuclear Information System (INIS)

    Kubota, Ryuji; Ueno, Takashi.

    1995-01-01

    The present invention provides an operation aid system for a plant having a large number of systematic equipments upon occurrence of an abnormality and a method of displaying it. Namely, contents of an operation manual upon occurrence of an abnormality is displayed in the form of a flow chart divided into a judging section and an operation section depending on symptoms of plant parameters. Discrimination numbers are provided to a plurality sets of the judging sections and the operation sections respectively. With such procedures, using various measured signals of the plant as inputted data, the discrimination numbers of the judging sections in accordance with the inputted data are stored. Then a flow chart for the judging sections and the operation sections corresponding to the stored discrimination numbers are displayed. Further, an operation manual upon occurrence of abnormalities relevant to the judging sections and the operation sections in the form of writings, and previously determined drawings of relevant systems and trend graphs of the plant are also displayed with reference to the discrimination numbers described above. As a result, both of an appropriate operation manual and relevant information are displayed simultaneously for the occurrence of a plant abnormality and an operator's erroneous operation. (I.S.)

  1. Visual merchandising window display

    Directory of Open Access Journals (Sweden)

    Opris (Cas. Stanila M.

    2013-12-01

    Full Text Available Window display plays a major part in the selling strategies; it does not only include the simple display of goods, nowadays it is a form of art, also having the purpose of sustaining the brand image. This article wants to reveal the tools that are essential in creating a fabulous window display. Being a window designer is not an easy job, you have to always think ahead trends, to have a sense of colour, to know how to use light to attract customers in the store after only one glance at the window. The big store window displays are theatre scenes: with expensive backgrounds, special effects and high fashion mannequins. The final role of the displays is to convince customers to enter the store and trigger the purchasing act which is the final goal of the retail activity.

  2. ACCURACY EVALUATION OF THE OBJECT LOCATION VISUALIZATION FOR GEO-INFORMATION AND DISPLAY SYSTEMS OF MANNED AIRCRAFTS NAVIGATION COMPLEXES

    Directory of Open Access Journals (Sweden)

    M. O. Kostishin

    2014-01-01

    Full Text Available The paper deals with the issue of accuracy estimating for the object location display in the geographic information systems and display systems of manned aircrafts navigation complexes. Application features of liquid crystal screens with a different number of vertical and horizontal pixels are considered at displaying of geographic information data on different scales. Estimation display of navigation parameters values on board the aircraft is done in two ways: a numeric value is directly displayed on the screen of multi-color indicator, and a silhouette of the object is formed on the screen on a substrate background, which is a graphical representation of area map in the flight zone. Various scales of area digital map display currently used in the aviation industry have been considered. Calculation results of one pixel scale interval, depending on the specifications of liquid crystal screen and zoom of the map display area on the multifunction digital display, are given. The paper contains experimental results of the accuracy evaluation for area position display of the aircraft based on the data from the satellite navigation system and inertial navigation system, obtained during the flight program run of the real object. On the basis of these calculations a family of graphs was created for precision error display of the object reference point position using the onboard indicators with liquid crystal screen with different screen resolutions (6 "×8", 7.2 "×9.6", 9"×12" for two map display scales (1:0 , 25 km, 1-2 km. These dependency graphs can be used both to assess the error value of object area position display in existing navigation systems and to calculate the error value in upgrading facilities.

  3. Nuclear Medicine Image Display. Chapter 14

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, H. [Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna (Austria)

    2014-12-15

    The final step in a medical imaging procedure is to display the image(s) on a suitable display system where it is presented to the medical specialist for diagnostic interpretation. The display of hard copy images on X ray film or photographic film has largely been replaced today by soft copy image display systems with cathode ray tube (CRT) or liquid crystal display (LCD) monitors as the image rendering device. Soft copy display requires a high quality display monitor and a certain amount of image processing to optimize the image both with respect to the properties of the display device and to some psychophysiological properties of the human visual system. A soft copy display system, therefore, consists of a display workstation providing some basic image processing functions and the display monitor as the intrinsic display device. Display devices of lower quality may be used during intermediate steps of the acquisition and analysis of a patient study. Display monitors with a quality suitable for diagnostic reading by the specialist medical doctor are called primary devices, also known as diagnostic devices. Monitors with lower quality but good enough to be used for positioning, processing of studies, presentation of images in the wards, etc. are referred to as secondary devices or clinical devices. Nuclear medicine images can be adequately displayed even for diagnostic purposes on secondary devices. However, the increasing use of X ray images on which to report jointly with images from nuclear medicine studies, such as those generated by dual modality imaging, notably by positron emission tomography (PET)/computed tomography (CT) and single photon emission computed tomography (SPECT)/CT, requires display devices capable of visualizing high resolution grey scale images at diagnostic quality, i.e. primary display devices. Both grey scale and colour display devices are used, the latter playing an important role in the display of processed nuclear medicine images and

  4. Nuclear Medicine Image Display. Chapter 14

    International Nuclear Information System (INIS)

    Bergmann, H.

    2014-01-01

    The final step in a medical imaging procedure is to display the image(s) on a suitable display system where it is presented to the medical specialist for diagnostic interpretation. The display of hard copy images on X ray film or photographic film has largely been replaced today by soft copy image display systems with cathode ray tube (CRT) or liquid crystal display (LCD) monitors as the image rendering device. Soft copy display requires a high quality display monitor and a certain amount of image processing to optimize the image both with respect to the properties of the display device and to some psychophysiological properties of the human visual system. A soft copy display system, therefore, consists of a display workstation providing some basic image processing functions and the display monitor as the intrinsic display device. Display devices of lower quality may be used during intermediate steps of the acquisition and analysis of a patient study. Display monitors with a quality suitable for diagnostic reading by the specialist medical doctor are called primary devices, also known as diagnostic devices. Monitors with lower quality but good enough to be used for positioning, processing of studies, presentation of images in the wards, etc. are referred to as secondary devices or clinical devices. Nuclear medicine images can be adequately displayed even for diagnostic purposes on secondary devices. However, the increasing use of X ray images on which to report jointly with images from nuclear medicine studies, such as those generated by dual modality imaging, notably by positron emission tomography (PET)/computed tomography (CT) and single photon emission computed tomography (SPECT)/CT, requires display devices capable of visualizing high resolution grey scale images at diagnostic quality, i.e. primary display devices. Both grey scale and colour display devices are used, the latter playing an important role in the display of processed nuclear medicine images and

  5. Problems in the optimum display of SPECT images

    International Nuclear Information System (INIS)

    Fielding, S.L.

    1988-01-01

    The instrumentation, computer hardware and software, and the image display system are all very important in the production of diagnostically useful SPECT images. Acquisition and processing parameters are discussed which can affect the quality of SPECT images. Regular quality control of the gamma camera and computer is important to keep the artifacts due to instrumentation to a minimum. The choice of reconstruction method will depend on the statistics in the study. The paper has shown that for high count rate studies, a high pass filter can be used to enhance the reconstructions. For lower count rate studies, pre-filtering is useful and the data can be reconstructed into thicker slices to reduce the effect of image noise. Finally, the optimum display for the images must be chosen, so that the information contained in the SPECT data can be easily perceived by the clinician. (orig.) [de

  6. Display systems for NPP control

    International Nuclear Information System (INIS)

    Rozov, S.S.

    1988-01-01

    Main trends in development of display systems used as the means for image displaying in NPP control systems are considered. It is shown that colour display devices appear to be the most universal means for concentrated data presentation. Along with digital means the display systems provide for high-speed response, sufficient for operative control of executive mechanisms. A conclusion is drawn that further development of display systems will move towards creation of large colour fields (on reflection base or with multicolour gas-discharge elements)

  7. SoftCopy Display Quality Assurance Program at Texas Children's Hospital.

    Science.gov (United States)

    Ly, Catherine Kim

    2002-01-01

    With growing dependence on picture archiving and communication systems for viewing images, a quality assurance program to monitor the condition of workstation displays has become increasingly important. At present there is no universally accepted program for PACS, but there are groups such as DICOM Working Group 11 of the ACR-NEMA and AAPM Task Group 18 that are working on image quality guidelines for interpretation from soft-copy displays. Texas Children's Hospital (TCH) is developing our own quality assurance program. Data is being collected to determine the appropriate frequency of calibration, the useful life of the displays, appropriate manufacturers, and model-dependent limits on maximum and minimum luminance (black level), symptoms of degradation, and monitor cleanliness. Our system includes a variety of monitors manufactured by Sun, AFP, Siemens, Image Systems, Barco, and Orwin. We are presently collecting data on individual monitor luminance functions but have not yet initiated service calls based on deviation from the DICOM Part 14 Grayscale Display Function (GSDF). The GSDF was intended to produce a grayscale in which driving levels produce changes in luminance that are perceptually equivalent throughout the entire luminance range for a specific test target. Our data is based on measurements of luminance from a digital Society of Motion Picture and Television Engineers (SMPTE) test pattern, which is a standard used by many other institutions. TCH's biomedical engineer measures luminance data each month from the display of the SMPTE pattern and record the results in a spreadsheet. The engineer also makes subjective evaluations of sharpness, geometric distortion, and artifacts. When a monitor's luminance falls outside of arbitrary 10% limits of maximum or minimum luminance, then a service call is placed to the vendor. The luminance check by the biomedical engineer is used to verify both routine and unscheduled calibrations. In addition to the monthly

  8. Real-time embedded system for stereo video processing for multiview displays

    Science.gov (United States)

    Berretty, R.-P. M.; Riemens, A. K.; Machado, P. F.

    2007-02-01

    In video systems, the introduction of 3D video might be the next revolution after the introduction of color. Nowadays multiview auto-stereoscopic displays are entering the market. Such displays offer various views at the same time. Depending on its positions, the viewers' eyes see different images. Hence, the viewers' left eye receives a signal that is different from what his right eye gets; this gives, provided the signals have been properly processed, the impression of depth. New auto-stereoscopic products use an image-plus-depth interface. On the other hand, a growing number of 3D productions from the entertainment industry use a stereo format. In this paper, we show how to compute depth from the stereo signal to comply with the display interface format. Furthermore, we present a realisation suitable for a real-time cost-effective implementation on an embedded media processor.

  9. Presidential laugh lines. Candidate display behavior and audience laughter in the 2008 primary debates.

    Science.gov (United States)

    Stewart, Patrick A

    2010-09-01

    Political humor has long been used by candidates to mobilize supporters by enhancing status or denigrating the opposition. Research concerning laughter provides insight into the building of social bonds; however, little research has focused on the nonverbal cues displayed by the individual making humorous comments. This study first investigates whether there is a relationship between facial display behavior and the presence and strength of laughter. Next, the analysis explores whether specific candidate displays during a humorous comment depend on the target of the comment. This paper analyzes the use of humor by Republican and Democratic candidates during ten 2008 presidential primary debates. Data analyzed here employs laughter as an indicator of a successful humorous comment and documents candidate display behavior in the seconds immediately preceding and during each laughter event. Findings suggest specific facial displays play an important communication role. Different types of smiles, whether felt, false, or fear-based, are related to who laughs as well as how intensely the audience is judged to laugh.

  10. Ribosome display: next-generation display technologies for production of antibodies in vitro.

    Science.gov (United States)

    He, Mingyue; Khan, Farid

    2005-06-01

    Antibodies represent an important and growing class of biologic research reagents and biopharmaceutical products. They can be used as therapeutics in a variety of diseases. With the rapid expansion of proteomic studies and biomarker discovery, there is a need for the generation of highly specific binding reagents to study the vast number of proteins encoded by the genome. Display technologies provide powerful tools for obtaining antibodies. Aside from the preservation of natural antibody repertoires, they are capable of exploiting diversity by DNA recombination to create very large libraries for selection of novel molecules. In contrast to in vivo immunization processes, display technologies allow selection of antibodies under in vitro-defined selection condition(s), resulting in enrichment of antibodies with desired properties from large populations. In addition, in vitro selection enables the isolation of antibodies against difficult antigens including self-antigens, and this can be applied to the generation of human antibodies against human targets. Display technologies can also be combined with DNA mutagenesis for antibody evolution in vitro. Some methods are amenable to automation, permitting high-throughput generation of antibodies. Ribosome display is considered as representative of the next generation of display technologies since it overcomes the limitations of cell-based display methods by using a cell-free system, offering advantages of screening larger libraries and continuously expanding new diversity during selection. Production of display-derived antibodies can be achieved by choosing one of a variety of prokaryotic and eukaryotic cell-based expression systems. In the near future, cell-free protein synthesis may be developed as an alternative for large-scale generation of antibodies.

  11. Service level status-a new real-time status display for IT services

    Energy Technology Data Exchange (ETDEWEB)

    Lopienski, S [IT Department, FIO group CERN, European Organization for Nuclear Research, 1211 Geneve 23 (Switzerland)], E-mail: Sebastian.Lopienski@cern.ch

    2008-07-15

    Nowadays, IT departments provide, and people use, computing services of an increasingly heterogeneous nature. There is thus a growing need for a status display that groups these different services and reports their status and availability in a uniform way. The Service Level Status (SLS) system addresses these needs by providing a web-based display that dynamically shows availability, basic information and statistics about various IT services, as well as the dependencies between them. This paper first introduces the requirements SLS had to meet, and the main concepts behind it, like service availability and status, Key Performance Indicators (KPIs), sub/meta-services, and service dependencies. It then describes the SLS system architecture, and some interesting implementation details, such as the usage of XML Schemas. Since clear visualization of service availability and status is one of the main goals of SLS, emphasis is put on describing the intuitive web-based user interface.

  12. Service level status-a new real-time status display for IT services

    International Nuclear Information System (INIS)

    Lopienski, S

    2008-01-01

    Nowadays, IT departments provide, and people use, computing services of an increasingly heterogeneous nature. There is thus a growing need for a status display that groups these different services and reports their status and availability in a uniform way. The Service Level Status (SLS) system addresses these needs by providing a web-based display that dynamically shows availability, basic information and statistics about various IT services, as well as the dependencies between them. This paper first introduces the requirements SLS had to meet, and the main concepts behind it, like service availability and status, Key Performance Indicators (KPIs), sub/meta-services, and service dependencies. It then describes the SLS system architecture, and some interesting implementation details, such as the usage of XML Schemas. Since clear visualization of service availability and status is one of the main goals of SLS, emphasis is put on describing the intuitive web-based user interface

  13. An organic white light-emitting dye: very small molecular architecture displays panchromatic emission.

    Science.gov (United States)

    Nandhikonda, Premchendar; Heagy, Michael D

    2010-11-14

    The synthesis and photophysical characterization of a new white-light fluorophore is described. The optimization of excitation wavelengths allows the naphthalimide (NI) dyes to display blue, green or white light emission depending on the excitation wavelength.

  14. Large-screen display industry: market and technology trends for direct view and projection displays

    Science.gov (United States)

    Castellano, Joseph A.; Mentley, David E.

    1996-03-01

    Large screen information displays are defined as dynamic electronic displays that can be viewed by more than one person and are at least 2-feet wide. These large area displays for public viewing provide convenience, entertainment, security, and efficiency to the viewers. There are numerous uses for large screen information displays including those in advertising, transportation, traffic control, conference room presentations, computer aided design, banking, and military command/control. A noticeable characteristic of the large screen display market is the interchangeability of display types. For any given application, the user can usually choose from at least three alternative technologies, and sometimes from many more. Some display types have features that make them suitable for specific applications due to temperature, brightness, power consumption, or other such characteristic. The overall worldwide unit consumption of large screen information displays of all types and for all applications (excluding consumer TV) will increase from 401,109 units in 1995 to 655,797 units in 2002. On a unit consumption basis, applications in business and education represent the largest share of unit consumption over this time period; in 1995, this application represented 69.7% of the total. The market (value of shipments) will grow from DOL3.1 billion in 1995 to DOL3.9 billion in 2002. The market will be dominated by front LCD projectors and LCD overhead projector plates.

  15. From Evolutionary Allometry to Sexual Display: (A Reply to Holman and Bro-Jørgensen).

    Science.gov (United States)

    Raia, Pasquale; Passaro, Federico; Carotenuto, Francesco; Meiri, Shai; Piras, Paolo

    2016-08-01

    Conventional wisdom holds that the complex shapes of deer antlers are produced under the sole influence of sexual selection. We questioned this view by demonstrating that trends for increased body size evolution passively yield more-complex ornaments, even in organisms where no effect of sexual selection is possible, with similar allometric slopes. Recent investigations suggest that sexual selection on antlers of larger deer species is stronger than that in smaller species; hence, the use of conspicuous antlers for display in large male deer is a secondary function driven by especially intense sexual selection on these large-bodied species. Since ancestral deer were small and had very simple antlers, such an intense selection on antlers shape was probably absent in early deer. Therefore, the evolution of complex ornaments is coupled with body size evolution, even in deer.

  16. The Integration Role of European Defense Procurement in Achieving a More Competitive and Stronger European Defense Equipment Market

    Science.gov (United States)

    2015-06-01

    and systems, even monopolistic ) essence of the supply side of the defense market . There are only a few suppliers that can meet today’s complex...DEFENSE PROCUREMENT IN ACHIEVING A MORE COMPETITIVE AND STRONGER EUROPEAN DEFENSE EQUIPMENT MARKET by Kiril O. Angelov June 2015 Thesis Advisor...COMPETITIVE AND STRONGER EUROPEAN DEFENSE EQUIPMENT MARKET 5. FUNDING NUMBERS 6. AUTHOR(S) Kiril O. Angelov 7. PERFORMING ORGANIZATION NAME(S) AND

  17. Increased fire frequency promotes stronger spatial genetic structure and natural selection at regional and local scales in Pinus halepensis Mill.

    Science.gov (United States)

    Budde, Katharina B; González-Martínez, Santiago C; Navascués, Miguel; Burgarella, Concetta; Mosca, Elena; Lorenzo, Zaida; Zabal-Aguirre, Mario; Vendramin, Giovanni G; Verdú, Miguel; Pausas, Juli G; Heuertz, Myriam

    2017-04-01

    The recurrence of wildfires is predicted to increase due to global climate change, resulting in severe impacts on biodiversity and ecosystem functioning. Recurrent fires can drive plant adaptation and reduce genetic diversity; however, the underlying population genetic processes have not been studied in detail. In this study, the neutral and adaptive evolutionary effects of contrasting fire regimes were examined in the keystone tree species Pinus halepensis Mill. (Aleppo pine), a fire-adapted conifer. The genetic diversity, demographic history and spatial genetic structure were assessed at local (within-population) and regional scales for populations exposed to different crown fire frequencies. Eight natural P. halepensis stands were sampled in the east of the Iberian Peninsula, five of them in a region exposed to frequent crown fires (HiFi) and three of them in an adjacent region with a low frequency of crown fires (LoFi). Samples were genotyped at nine neutral simple sequence repeats (SSRs) and at 251 single nucleotide polymorphisms (SNPs) from coding regions, some of them potentially important for fire adaptation. Fire regime had no effects on genetic diversity or demographic history. Three high-differentiation outlier SNPs were identified between HiFi and LoFi stands, suggesting fire-related selection at the regional scale. At the local scale, fine-scale spatial genetic structure (SGS) was overall weak as expected for a wind-pollinated and wind-dispersed tree species. HiFi stands displayed a stronger SGS than LoFi stands at SNPs, which probably reflected the simultaneous post-fire recruitment of co-dispersed related seeds. SNPs with exceptionally strong SGS, a proxy for microenvironmental selection, were only reliably identified under the HiFi regime. An increasing fire frequency as predicted due to global change can promote increased SGS with stronger family structures and alter natural selection in P. halepensis and in plants with similar life history traits

  18. Testing for long-range dependence in world stock markets

    OpenAIRE

    Cajueiro, Daniel Oliveira; Tabak, Benjamin Miranda

    2008-01-01

    In this paper, we show a novel approach to rank stock market indices in terms of weak form efficiency using state of the art methodology in statistical physics. We employ the R/S and V/S methodologies to test for long-range dependence in equity returns and volatility. Empirical results suggests that although emerging markets possess stronger long-range dependence in equity returns than developed economies, this is not true for volatility. In the case of volatility, Hurst exponents...

  19. Scalable Resolution Display Walls

    KAUST Repository

    Leigh, Jason; Johnson, Andrew; Renambot, Luc; Peterka, Tom; Jeong, Byungil; Sandin, Daniel J.; Talandis, Jonas; Jagodic, Ratko; Nam, Sungwon; Hur, Hyejung; Sun, Yiwen

    2013-01-01

    This article will describe the progress since 2000 on research and development in 2-D and 3-D scalable resolution display walls that are built from tiling individual lower resolution flat panel displays. The article will describe approaches and trends in display hardware construction, middleware architecture, and user-interaction design. The article will also highlight examples of use cases and the benefits the technology has brought to their respective disciplines. © 1963-2012 IEEE.

  20. System analysis of formation and perception processes of three-dimensional images in volumetric displays

    Science.gov (United States)

    Bolshakov, Alexander; Sgibnev, Arthur

    2018-03-01

    One of the promising devices is currently a volumetric display. Volumetric displays capable to visualize complex three-dimensional information as nearly as possible to its natural – volume form without the use of special glasses. The invention and implementation of volumetric display technology will expand opportunities of information visualization in various spheres of human activity. The article attempts to structure and describe the interrelation of the essential characteristics of objects in the area of volumetric visualization. Also there is proposed a method of calculation of estimate total number of voxels perceived by observers during the 3D demonstration, generated using a volumetric display with a rotating screen. In the future, it is planned to expand the described technique and implement a system for estimation the quality of generated images, depending on the types of biplanes and their initial characteristics.

  1. X-Windows Widget for Image Display

    Science.gov (United States)

    Deen, Robert G.

    2011-01-01

    XvicImage is a high-performance XWindows (Motif-compliant) user interface widget for displaying images. It handles all aspects of low-level image display. The fully Motif-compliant image display widget handles the following tasks: (1) Image display, including dithering as needed (2) Zoom (3) Pan (4) Stretch (contrast enhancement, via lookup table) (5) Display of single-band or color data (6) Display of non-byte data (ints, floats) (7) Pseudocolor display (8) Full overlay support (drawing graphics on image) (9) Mouse-based panning (10) Cursor handling, shaping, and planting (disconnecting cursor from mouse) (11) Support for all user interaction events (passed to application) (12) Background loading and display of images (doesn't freeze the GUI) (13) Tiling of images.

  2. Study on the visibility of an electroluminescent display for automobiles; Jidoshayo EL display no shininsei

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, N; Harada, M; Idogaki, T [Denso Corp., Aichi (Japan)

    1997-10-01

    This report explores the visibility of an Electroluminescent (EL) display for automotive use. Displays for automobiles are exposed to the direct rays of the sun and forced to operate in wide temperature range. Therefore, luminous flux density by the lighting on EL display panel and operating environment temperature must be considered for the visibility evaluation. Sensory evaluation on the visibility and physical measurements such as contrast, chromaticity difference in accordance with the viewing angle change indicate that the visibility of the EL display for automobiles is advantageous over other displays. 6 refs., 11 figs., 1 tab.

  3. Actively addressed single pixel full-colour plasmonic display

    Science.gov (United States)

    Franklin, Daniel; Frank, Russell; Wu, Shin-Tson; Chanda, Debashis

    2017-05-01

    Dynamic, colour-changing surfaces have many applications including displays, wearables and active camouflage. Plasmonic nanostructures can fill this role by having the advantages of ultra-small pixels, high reflectivity and post-fabrication tuning through control of the surrounding media. However, previous reports of post-fabrication tuning have yet to cover a full red-green-blue (RGB) colour basis set with a single nanostructure of singular dimensions. Here, we report a method which greatly advances this tuning and demonstrates a liquid crystal-plasmonic system that covers the full RGB colour basis set, only as a function of voltage. This is accomplished through a surface morphology-induced, polarization-dependent plasmonic resonance and a combination of bulk and surface liquid crystal effects that manifest at different voltages. We further demonstrate the system's compatibility with existing LCD technology by integrating it with a commercially available thin-film-transistor array. The imprinted surface interfaces readily with computers to display images as well as video.

  4. Laser illuminated flat panel display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T.

    1995-12-31

    A 10 inch laser illuminated flat panel Planar Optic Display (POD) screen has been constructed and tested. This POD screen technology is an entirely new concept in display technology. Although the initial display is flat and made of glass, this technology lends itself to applications where a plastic display might be wrapped around the viewer. The display screen is comprised of hundreds of planar optical waveguides where each glass waveguide represents a vertical line of resolution. A black cladding layer, having a lower index of refraction, is placed between each waveguide layer. Since the cladding makes the screen surface black, the contrast is high. The prototype display is 9 inches wide by 5 inches high and approximately I inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  5. OLED displays and lighting

    CERN Document Server

    Koden, Mitsuhiro

    2017-01-01

    Organic light-emitting diodes (OLEDs) have emerged as the leading technology for the new display and lighting market. OLEDs are solid-state devices composed of thin films of organic molecules that create light with the application of electricity. OLEDs can provide brighter, crisper displays on electronic devices and use less power than conventional light-emitting diodes (LEDs) or liquid crystal displays (LCDs) used today. This book covers both the fundamentals and practical applications of flat and flexible OLEDs.

  6. Gas Marbles: Much Stronger than Liquid Marbles

    Science.gov (United States)

    Timounay, Yousra; Pitois, Olivier; Rouyer, Florence

    2017-06-01

    Enwrapping liquid droplets with hydrophobic particles allows the manufacture of so-called "liquid marbles" [Aussillous and Quéré Nature (London) 411, 924 (2001); , 10.1038/35082026Mahadevan Nature (London)411, 895 (2001), 10.1038/35082164]. The recent intensive research devoted to liquid marbles is justified by their very unusual physical and chemical properties and by their potential for various applications, from microreactors to water storage, including water pollution sensors [Bormashenko Curr. Opin. Colloid Interface Sci. 16, 266 (2011), 10.1016/j.cocis.2010.12.002]. Here we demonstrate that this concept can be successfully applied for encapsulating and protecting small gas pockets within an air environment. Similarly to their liquid counterparts, those new soft-matter objects, that we call "gas marbles," can sustain external forces. We show that gas marbles are surprisingly tenfold stronger than liquid marbles and, more importantly, they can sustain both positive and negative pressure differences. This magnified strength is shown to originate from the strong cohesive nature of the shell. Those interesting properties could be exploited for imprisoning valuable or polluted gases or for designing new aerated materials.

  7. Energy Sharing and Energy Feedback: Affective and Behavioral Reactions to Communal Energy Displays

    Energy Technology Data Exchange (ETDEWEB)

    Leygue, Caroline, E-mail: caroline.leygue@nottingham.ac.uk [Horizon Digital Economy Research, University of Nottingham, Nottingham (United Kingdom); Ferguson, Eamonn [School of Psychology, University of Nottingham, Nottingham (United Kingdom); Skatova, Anya [Horizon Digital Economy Research, University of Nottingham, Nottingham (United Kingdom); Spence, Alexa [Horizon Digital Economy Research, University of Nottingham, Nottingham (United Kingdom); School of Psychology, University of Nottingham, Nottingham (United Kingdom)

    2014-07-25

    Smart meters and energy displays are being rolled out in many countries to help individuals monitor and reduce their energy usage. However, to date, there is little in depth understanding of how they may change behavior. While there is currently a great deal of technical research into developing smart metering, little research has been conducted on how this affects the energy user. This research addresses this gap and explores the user perspective of energy displays when energy is considered as a shared resource. We report an online experiment conducted across the UK examining affective and behavioral responses to energy sharing situations incorporating different types of energy displays. Reactions differed depending on the type of display. In a situation where one person used more than their fair share of energy, displays showing the average amount of usage in the house were associated with feelings of guilt and fear and a decrease in intention to use energy. Displays that identified the person who overused the resource were associated with anger, and direct sanction intentions on those who were overusing energy. Findings are discussed in terms of the smart meter rollout and the potential utility of detailed energy monitoring technologies for behavior change.

  8. Energy sharing and energy feedback: Affective and behavioral reactions to communal energy displays.

    Directory of Open Access Journals (Sweden)

    Caroline eLeygue

    2014-07-01

    Full Text Available Smart meters and energy displays are being rolled out in many countries to help individuals monitor and reduce their energy usage. However, to date there is little in depth understanding of how they may change behavior. While there is currently a great deal of technical research into developing smart metering, little research has been conducted on how this affects the energy user. This research addresses this gap and explores the user perspective of energy displays when energy is considered as a shared resource. We report an online experiment conducted across the UK examining affective and behavioral responses to energy sharing situations incorporating different types of energy displays. Reactions differed depending on the type of display. In a situation where one person used more than their fair share of energy, displays showing the average amount of usage in the house were associated with feelings of guilt and fear and a decrease in intention to use energy. Displays that identified the person who overused the resource were associated with anger, and direct sanction intentions on those who were overusing energy. Findings are discussed in terms of the smart meter rollout and the potential utility of detailed energy monitoring technologies for behavior change.

  9. Energy Sharing and Energy Feedback: Affective and Behavioral Reactions to Communal Energy Displays

    International Nuclear Information System (INIS)

    Leygue, Caroline; Ferguson, Eamonn; Skatova, Anya; Spence, Alexa

    2014-01-01

    Smart meters and energy displays are being rolled out in many countries to help individuals monitor and reduce their energy usage. However, to date, there is little in depth understanding of how they may change behavior. While there is currently a great deal of technical research into developing smart metering, little research has been conducted on how this affects the energy user. This research addresses this gap and explores the user perspective of energy displays when energy is considered as a shared resource. We report an online experiment conducted across the UK examining affective and behavioral responses to energy sharing situations incorporating different types of energy displays. Reactions differed depending on the type of display. In a situation where one person used more than their fair share of energy, displays showing the average amount of usage in the house were associated with feelings of guilt and fear and a decrease in intention to use energy. Displays that identified the person who overused the resource were associated with anger, and direct sanction intentions on those who were overusing energy. Findings are discussed in terms of the smart meter rollout and the potential utility of detailed energy monitoring technologies for behavior change.

  10. The consumer’s choice among television displays: A multinomial logit approach

    Directory of Open Access Journals (Sweden)

    Carlos Giovanni González Espitia

    2013-07-01

    Full Text Available The consumer’s choice over a bundle of products depends on observable and unobservable characteristics of goods and consumers. This choice is made in order to maximize utility subject to a budget constraint. At the same time, firms make product differentiation decisions to maximize profit. Quality is a form of differentiation. An example of this occurs in the TV market, where several displays are developed. Our objective is to determine the probability for a consumer of choosing a type of display from among five kinds: standard tube, LCD, plasma, projection and LED. Using a multinomial logit approach, we find that electronic appliances like DVDs and audio systems, as well as socioeconomic status, increase the probability of choosing a high-tech television display. Our empirical approximation contributes to further understanding rational consumer behavior through the theory of utility maximization and highlights the importance of studying market structure and analyzing changes in welfare and efficiency.

  11. Dichroic Liquid Crystal Displays

    Science.gov (United States)

    Bahadur, Birendra

    The following sections are included: * INTRODUCTION * DICHROIC DYES * Chemical Structure * Chemical and Photochemical Stability * THEORETICAL MODELLING * DEFECTS CAUSED BY PROLONGED LIGHT IRRADIATION * CHEMICAL STRUCTURE AND PHOTOSTABILITY * OTHER PARAMETERS AFFECTING PHOTOSTABILITY * CELL PREPARATION * DICHROIC PARAMETERS AND THEIR MEASUREMENTS * Order Parameter and Dichroic Ratio Of Dyes * Absorbance, Order Parameter and Dichroic Ratio Measurements * IMPACT OF DYE STRUCTURE AND LIQUID CRYSTAL HOST ON PHYSICAL PROPERTIES OF A DICHROIC MIXTURE * Order Parameter and Dichroic Ratio * EFFECT OF LENGTH OF DICHROIC DYES ON THE ORDER PARAMETER * EFFECT OF THE BREADTH OF DYE ON THE ORDER PARAMETER * EFFECT OF THE HOST ON THE ORDER PARAMETER * TEMPERATURE VARIATION OF THE ORDER PARAMETER OF DYES IN A LIQUID CRYSTAL HOST * IMPACT OF DYE CONCENTRATION ON THE ORDER PARAMETER * Temperature Range * Viscosity * Dielectric Constant and Anisotropy * Refractive Indices and Birefringence * solubility43,153-156 * Absorption Wavelength and Auxochromic Groups * Molecular Engineering of Dichroic Dyes * OPTICAL, ELECTRO-OPTICAL AND LIFE PARAMETERS * Colour And CIE Colour space120,160-166 * CIE 1931 COLOUR SPACE * CIE 1976 CHROMATICITY DIAGRAM * CIE UNIFORM COLOUR SPACES & COLOUR DIFFERENCE FORMULAE120,160-166 * Electro-Optical Parameters120 * LUMINANCE * CONTRAST AND CONTRAST RATIO * SWITCHING SPEED * Life Parameters and Failure Modes * DICHROIC MIXTURE FORMULATION * Monochrome Mixture * Black Mixture * ACHROMATIC BLACK MIXTURE FOR HEILMEIER DISPLAYS * Effect of Illuminant on Display Colour * Colour of the Field-On State * Effect of Dye Linewidth * Optimum Centroid Wavelengths * Effect of Dye Concentration * Mixture Formulation Using More Than Three Dyes * ACHROMATIC MIXTURE FOR WHITE-TAYLOR TYPE DISPLAYS * HEILMEIER DISPLAYS * Theoretical Modelling * Threshold Characteristic * Effects of Dye Concentration on Electro-optical Parameters * Effect of Cholesteric Doping * Effect of Alignment

  12. Bactericidal activity of LFchimera is stronger and less sensitive to ionic strength than its constituent lactoferricin and lactoferrampin peptides.

    Science.gov (United States)

    Bolscher, Jan G M; Adão, Regina; Nazmi, Kamran; van den Keybus, Petra A M; van 't Hof, Wim; Nieuw Amerongen, Arie V; Bastos, Margarida; Veerman, Enno C I

    2009-01-01

    The innate immunity factor lactoferrin harbours two antimicrobial moieties, lactoferricin and lactoferrampin, situated in close proximity in the N1 domain of the molecule. Most likely they cooperate in many of the beneficial activities of lactoferrin. To investigate whether chimerization of both peptides forms a functional unit we designed a chimerical structure containing lactoferricin amino acids 17-30 and lactoferrampin amino acids 265-284. The bactericidal activity of this LFchimera was found to be drastically stronger than that of the constituent peptides, as was demonstrated by the need for lower dose, shorter incubation time and less ionic strength dependency. Likewise, strongly enhanced interaction with negatively charged model membranes was found for the LFchimera relative to the constituent peptides. Thus, chimerization of the two antimicrobial peptides resembling their structural orientation in the native molecule strikingly improves their biological activity.

  13. Transgenic mice expressing constitutive active MAPKAPK5 display gender-dependent differences in exploration and activity

    Directory of Open Access Journals (Sweden)

    Moens Ugo

    2007-11-01

    Full Text Available Abstract Background The mitogen-activated protein kinases, MAPKs for short, constitute cascades of signalling pathways involved in the regulation of several cellular processes that include cell proliferation, differentiation and motility. They also intervene in neurological processes like fear conditioning and memory. Since little remains known about the MAPK-Activated Protein Kinase, MAPKAPK5, we constructed the first MAPKAPK knockin mouse model, using a constitutive active variant of MAPKAPK5 and analyzed the resulting mice for changes in anxiety-related behaviour. Methods We performed primary SHIRPA observations during background breeding into the C57BL/6 background and assessed the behaviour of the background-bred animals on the elevated plus maze and in the light-dark test. Our results were analyzed using Chi-square tests and homo- and heteroscedatic T-tests. Results Female transgenic mice displayed increased amounts of head dips and open arm time on the maze, compared to littermate controls. In addition, they also explored further into the open arm on the elevated plus maze and were less active in the closed arm compared to littermate controls. Male transgenic mice displayed no differences in anxiety, but their locomotor activity increased compared to non-transgenic littermates. Conclusion Our results revealed anxiety-related traits and locomotor differences between transgenic mice expressing constitutive active MAPKAPK5 and control littermates.

  14. Crosstalk evaluation in stereoscopic displays

    NARCIS (Netherlands)

    Wang, L.; Teunissen, C.; Tu, Yan; Chen, Li; Zhang, P.; Zhang, T.; Heynderickx, I.E.J.

    2011-01-01

    Substantial progress in liquid-crystal display and polarization film technology has enabled several types of stereoscopic displays. Despite all progress, some image distortions still exist in these 3-D displays, of which interocular crosstalk - light leakage of the image for one eye to the other eye

  15. Optical simulation of quantum algorithms using programmable liquid-crystal displays

    International Nuclear Information System (INIS)

    Puentes, Graciana; La Mela, Cecilia; Ledesma, Silvia; Iemmi, Claudio; Paz, Juan Pablo; Saraceno, Marcos

    2004-01-01

    We present a scheme to perform an all optical simulation of quantum algorithms and maps. The main components are lenses to efficiently implement the Fourier transform and programmable liquid-crystal displays to introduce space dependent phase changes on a classical optical beam. We show how to simulate Deutsch-Jozsa and Grover's quantum algorithms using essentially the same optical array programmed in two different ways

  16. Assessing nicotine dependence in adolescent E-cigarette users: The 4-item Patient-Reported Outcomes Measurement Information System (PROMIS) Nicotine Dependence Item Bank for electronic cigarettes.

    Science.gov (United States)

    Morean, Meghan E; Krishnan-Sarin, Suchitra; S O'Malley, Stephanie

    2018-04-26

    Adolescent e-cigarette use (i.e., "vaping") likely confers risk for developing nicotine dependence. However, there have been no studies assessing e-cigarette nicotine dependence in youth. We evaluated the psychometric properties of the 4-item Patient-Reported Outcomes Measurement Information System Nicotine Dependence Item Bank for E-cigarettes (PROMIS-E) for assessing youth e-cigarette nicotine dependence and examined risk factors for experiencing stronger dependence symptoms. In 2017, 520 adolescent past-month e-cigarette users completed the PROMIS-E during a school-based survey (50.5% female, 84.8% White, 16.22[1.19] years old). Adolescents also reported on sex, grade, race, age at e-cigarette use onset, vaping frequency, nicotine e-liquid use, and past-month cigarette smoking. Analyses included conducting confirmatory factor analysis and examining the internal consistency of the PROMIS-E. Bivariate correlations and independent-samples t-tests were used to examine unadjusted relationships between e-cigarette nicotine dependence and the proposed risk factors. Regression models were run in which all potential risk factors were entered as simultaneous predictors of PROMIS-E scores. The single-factor structure of the PROMIS-E was confirmed and evidenced good internal consistency. Across models, larger PROMIS-E scores were associated with being in a higher grade, initiating e-cigarette use at an earlier age, vaping more frequently, using nicotine e-liquid (and higher nicotine concentrations), and smoking cigarettes. Adolescent e-cigarette users reported experiencing nicotine dependence, which was assessed using the psychometrically sound PROMIS-E. Experiencing stronger nicotine dependence symptoms was associated with characteristics that previously have been shown to confer risk for frequent vaping and tobacco cigarette dependence. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Using k-dependence causal forest to mine the most significant dependency relationships among clinical variables for thyroid disease diagnosis.

    Directory of Open Access Journals (Sweden)

    LiMin Wang

    Full Text Available Numerous data mining models have been proposed to construct computer-aided medical expert systems. Bayesian network classifiers (BNCs are more distinct and understandable than other models. To graphically describe the dependency relationships among clinical variables for thyroid disease diagnosis and ensure the rationality of the diagnosis results, the proposed k-dependence causal forest (KCF model generates a series of submodels in the framework of maximum spanning tree (MST and demonstrates stronger dependence representation. Friedman test on 12 UCI datasets shows that KCF has classification accuracy advantage over the other state-of-the-art BNCs, such as Naive Bayes, tree augmented Naive Bayes, and k-dependence Bayesian classifier. Our extensive experimental comparison on 4 medical datasets also proves the feasibility and effectiveness of KCF in terms of sensitivity and specificity.

  18. Consortium for military LCD display procurement

    Science.gov (United States)

    Echols, Gregg

    2002-08-01

    International Display Consortium (IDC) is the joining together of display companies to combined their buying power and obtained favorable terms with a major LCD manufacturer. Consolidating the buying power and grouping the demand enables the rugged display industry of avionics, ground vehicles, and ship based display manufacturers to have unencumbered access to high performance AMLCDs while greatly reducing risk and lowering cost. With an unrestricted supply of AMLCD displays, the consortium members have total control of their risk, cost, deliveries and added value partners. Every display manufacturer desires a very close relationship with a display vender. With IDC each consortium member achieves a close relationship. Consortium members enjoy cost effective access to high performance, industry standard sized LCD panels, and modified commercial displays with 100 degree C clearing points and portrait configurations. Consortium members also enjoy proposal support, technical support and long-term support.

  19. Super high precision 200 ppi liquid crystal display series; Chokoseido 200 ppi ekisho display series

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    In mobile equipment, in demand is a high precision liquid crystal display (LCD) having the power of expression equivalent to printed materials like magazines because of the necessity of displaying a large amount of information on a easily potable small screen. In addition, with the spread and high-quality image of digital still cameras, it is strongly desired to display photographed digital image data in high quality. Toshiba Corp., by low temperature polysilicone (p-Si) technology, commercialized the liquid crystal display series of 200 ppi (pixels per inch) precision dealing with the rise of the high-precision high-image quality LCD market. The super high precision of 200 ppi enables the display of smooth beautiful animation comparable to printed sheets of magazines and photographs. The display series are suitable for the display of various information services such as electronic books and electronic photo-viewers including internet. The screen sizes lined up are No. 4 type VGA (640x480 pixels) of a small pocket notebook size and No. 6.3 type XGA (1,024x768 pixels) of a paperback size, with a larger screen to be furthered. (translated by NEDO)

  20. A Compressive Superresolution Display

    KAUST Repository

    Heide, Felix; Gregson, James; Wetzstein, Gordon; Raskar, Ramesh; Heidrich, Wolfgang

    2014-01-01

    In this paper, we introduce a new compressive display architecture for superresolution image presentation that exploits co-design of the optical device configuration and compressive computation. Our display allows for superresolution, HDR, or glasses-free 3D presentation.

  1. A Compressive Superresolution Display

    KAUST Repository

    Heide, Felix

    2014-06-22

    In this paper, we introduce a new compressive display architecture for superresolution image presentation that exploits co-design of the optical device configuration and compressive computation. Our display allows for superresolution, HDR, or glasses-free 3D presentation.

  2. Nonlinear mapping of the luminance in dual-layer high dynamic range displays

    Science.gov (United States)

    Guarnieri, Gabriele; Ramponi, Giovanni; Bonfiglio, Silvio; Albani, Luigi

    2009-02-01

    It has long been known that the human visual system (HVS) has a nonlinear response to luminance. This nonlinearity can be quantified using the concept of just noticeable difference (JND), which represents the minimum amplitude of a specified test pattern an average observer can discern from a uniform background. The JND depends on the background luminance following a threshold versus intensity (TVI) function. It is possible to define a curve which maps physical luminances into a perceptually linearized domain. This mapping can be used to optimize a digital encoding, by minimizing the visibility of quantization noise. It is also commonly used in medical applications to display images adapting to the characteristics of the display device. High dynamic range (HDR) displays, which are beginning to appear on the market, can display luminance levels outside the range in which most standard mapping curves are defined. In particular, dual-layer LCD displays are able to extend the gamut of luminance offered by conventional liquid crystals towards the black region; in such areas suitable and HVS-compliant luminance transformations need to be determined. In this paper we propose a method, which is primarily targeted to the extension of the DICOM curve used in medical imaging, but also has a more general application. The method can be modified in order to compensate for the ambient light, which can be significantly greater than the black level of an HDR display and consequently reduce the visibility of the details in dark areas.

  3. Neural response in obsessive-compulsive washers depends on individual fit of triggers

    Directory of Open Access Journals (Sweden)

    Ali eBaioui

    2013-04-01

    Full Text Available BackgroundPatients with obsessive-compulsive disorder (OCD have highly idiosyncratic triggers. To fully understand which role this idiosyncrasy plays in the neurobiological mechanisms behind OCD, it is necessary to elucidate the impact of individualization regarding the applied investigation methods.This functional magnetic resonance imaging (fMRI study explores the neural correlates of contamination/washing-related OCD with a highly individualized symptom provocation paradigm. Additionally, it is the first study to directly compare individualized and standardized symptom provocation. MethodsNineteen patients with washing compulsions created individual OCD hierarchies, which later served as instructions to photograph their own individualized stimulus sets. The patients and 19 case-by-case matched healthy controls participated in a symptom provocation fMRI experiment with individualized and standardized stimulus sets created for each patient. ResultsOCD patients compared to healthy controls displayed stronger activation in the basal ganglia (nucleus accumbens, nucleus caudatus, pallidum for individualized symptom provocation. Using standardized symptom provocation, this group comparison led to stronger activation in the nucleus caudatus. The direct comparison of between-group effects for both symptom provocation approaches revealed stronger activation of the orbitofronto-striatal network for individualized symptom provocation.ConclusionsThe present study provides insight into the differential impact of individualized and standardized symptom provocation on the orbitofronto-striatal network of OCD washers. Behavioral and neural responses imply a higher symptom-specificity of individualized symptom provocation.

  4. JTEC panel on display technologies in Japan

    Science.gov (United States)

    Tannas, Lawrence E., Jr.; Glenn, William E.; Credelle, Thomas; Doane, J. William; Firester, Arthur H.; Thompson, Malcolm

    1992-01-01

    This report is one in a series of reports that describes research and development efforts in Japan in the area of display technologies. The following are included in this report: flat panel displays (technical findings, liquid crystal display development and production, large flat panel displays (FPD's), electroluminescent displays and plasma panels, infrastructure in Japan's FPD industry, market and projected sales, and new a-Si active matrix liquid crystal display (AMLCD) factory); materials for flat panel displays (liquid crystal materials, and light-emissive display materials); manufacturing and infrastructure of active matrix liquid crystal displays (manufacturing logistics and equipment); passive matrix liquid crystal displays (LCD basics, twisted nematics LCD's, supertwisted nematic LCD's, ferroelectric LCD's, and a comparison of passive matrix LCD technology); active matrix technology (basic active matrix technology, investment environment, amorphous silicon, polysilicon, and commercial products and prototypes); and projection displays (comparison of Japanese and U.S. display research, and technical evaluation of work).

  5. Australian Children's Understanding of Display Rules

    Science.gov (United States)

    Choy, Grace

    2009-01-01

    Cultural display rules govern the manifestation of emotional expressions. In compliance with display rules, the facial expressions displayed (i.e. apparent emotion) may be incongruent with the emotion experienced (i.e. real emotion). This study investigates Australian Caucasian children's understanding of display rules. A sample of 80 four year…

  6. The case for transparent depth display

    NARCIS (Netherlands)

    Kooi, F.L.

    2003-01-01

    Purpose: The continuing developments in display technology have resulted in the ability to present increasing amounts of data on computer displays. One of the coming break-throughs is generally believed to be the introduction of '3-D displays': displays with a true sense of depth. Though these types

  7. New ultraportable display technology and applications

    Science.gov (United States)

    Alvelda, Phillip; Lewis, Nancy D.

    1998-08-01

    MicroDisplay devices are based on a combination of technologies rooted in the extreme integration capability of conventionally fabricated CMOS active-matrix liquid crystal display substrates. Customized diffraction grating and optical distortion correction technology for lens-system compensation allow the elimination of many lenses and systems-level components. The MicroDisplay Corporation's miniature integrated information display technology is rapidly leading to many new defense and commercial applications. There are no moving parts in MicroDisplay substrates, and the fabrication of the color generating gratings, already part of the CMOS circuit fabrication process, is effectively cost and manufacturing process-free. The entire suite of the MicroDisplay Corporation's technologies was devised to create a line of application- specific integrated circuit single-chip display systems with integrated computing, memory, and communication circuitry. Next-generation portable communication, computer, and consumer electronic devices such as truly portable monitor and TV projectors, eyeglass and head mounted displays, pagers and Personal Communication Services hand-sets, and wristwatch-mounted video phones are among the may target commercial markets for MicroDisplay technology. Defense applications range from Maintenance and Repair support, to night-vision systems, to portable projectors for mobile command and control centers.

  8. Bibliographic Displays in OPACs and Web Catalogs: How Well Do They Comply with Display Guidelines?

    Science.gov (United States)

    Cherry, Joan M.

    1998-01-01

    Evaluation of data from assessments of full bibliographic displays in academic library OPACs (online public access catalogs) and World Wide Web catalogs against a checklist of desirable features found that OPAC displays scored 58% and Web displays scored 60%. Discusses weaknesses, focusing on those found in the majority of the displays…

  9. A nanobody:GFP bacterial platform that enables functional enzyme display and easy quantification of display capacity

    DEFF Research Database (Denmark)

    Wendel, Sofie; Christian Fischer, Emil; Martinez, Virginia

    2016-01-01

    Background: Bacterial surface display is an attractive technique for the production of cell-anchored, functional proteins and engineering of whole-cell catalysts. Although various outer membrane proteins have been used for surface display, an easy and versatile high-throughput-compatible assay...... to displaying the nanobody alone. We used flow cytometry to analyse display capability on single-cell versus population level and found that the signal peptide of the anchor has great effect on display efficiency.Conclusions: We have developed an inexpensive and easy read-out assay for surface display using...... nanobody: GFP interactions. The assay is compatible with the most common fluorescence detection methods, including multi-well plate whole-cell fluorescence detection, SDS-PAGE in-gel fluorescence, microscopy and flow cytometry. We anticipate that the platform will facilitate future in-depth studies...

  10. Large Display Interaction via Multiple Acceleration Curves and Multifinger Pointer Control

    Directory of Open Access Journals (Sweden)

    Andrey Esakia

    2014-01-01

    Full Text Available Large high-resolution displays combine high pixel density with ample physical dimensions. The combination of these factors creates a multiscale workspace where interactive targeting of on-screen objects requires both high speed for distant targets and high accuracy for small targets. Modern operating systems support implicit dynamic control-display gain adjustment (i.e., a pointer acceleration curve that helps to maintain both speed and accuracy. However, large high-resolution displays require a broader range of control-display gains than a single acceleration curve can usably enable. Some interaction techniques attempt to solve the problem by utilizing multiple explicit modes of interaction, where different modes provide different levels of pointer precision. Here, we investigate the alternative hypothesis of using a single mode of interaction for continuous pointing that enables both (1 standard implicit granularity control via an acceleration curve and (2 explicit switching between multiple acceleration curves in an efficient and dynamic way. We evaluate a sample solution that augments standard touchpad accelerated pointer manipulation with multitouch capability, where the choice of acceleration curve dynamically changes depending on the number of fingers in contact with the touchpad. Specifically, users can dynamically switch among three different acceleration curves by using one, two, or three fingers on the touchpad.

  11. Reconfigurable Full-Page Braille Displays

    Science.gov (United States)

    Garner, H. Douglas

    1994-01-01

    Electrically actuated braille display cells of proposed type arrayed together to form full-page braille displays. Like other braille display cells, these provide changeable patterns of bumps driven by digitally recorded text stored on magnetic tapes or in solid-state electronic memories. Proposed cells contain electrorheological fluid. Viscosity of such fluid increases in strong electrostatic field.

  12. Construction of human antibody gene libraries and selection of antibodies by phage display.

    Science.gov (United States)

    Frenzel, André; Kügler, Jonas; Wilke, Sonja; Schirrmann, Thomas; Hust, Michael

    2014-01-01

    Antibody phage display is the most commonly used in vitro selection technology and has yielded thousands of useful antibodies for research, diagnostics, and therapy.The prerequisite for successful generation and development of human recombinant antibodies using phage display is the construction of a high-quality antibody gene library. Here, we describe the methods for the construction of human immune and naive scFv gene libraries.The success also depends on the panning strategy for the selection of binders from these libraries. In this article, we describe a panning strategy that is high-throughput compatible and allows parallel selection in microtiter plates.

  13. Display-management system for MFTF

    International Nuclear Information System (INIS)

    Nelson, D.O.

    1981-01-01

    The Mirror Fusion Test Facility (MFTF) is controlled by 65 local control microcomputers which are supervised by a local network of nine 32-bit minicomputers. Associated with seven of the nine computers are state-of-the-art graphics devices, each with extensive local processing capability. These devices provide the means for an operator to interact with the control software running on the minicomputers. It is critical that the information the operator views accurately reflects the current state of the experiment. This information is integrated into dynamically changing pictures called displays. The primary organizational component of the display system is the software-addressable segment. The segments created by the display creation software are managed by display managers associated with each graphics device. Each display manager uses sophisticated storage management mechanisms to keep the proper segments resident in the local graphics device storage

  14. Data display with the Q system

    International Nuclear Information System (INIS)

    Oothoudt, M.A.

    1979-01-01

    The Q data-acquisition system for PDP-11 mini-computers at the Clinton P. Anderson Meson Physics Facility (LAMPF) provides experimenters with basic tools for on-line data display. Tasks are available to plot one- and two-parameter histograms on Tektronix 4000 series storage-tube terminals. The histograms to be displayed and the display format may be selected with simple keyboard commands. A task is also available to create and display live two-parameter scatter plots for any acquired or calculated quantities. Other tasks in the system manage the display data base, list display parameters and histogram contents on hardcopy devices, and save core histograms on disk or tape for off-line analysis. 8 figures

  15. Orangutans modify facial displays depending on recipient attention

    Directory of Open Access Journals (Sweden)

    Bridget M. Waller

    2015-03-01

    Full Text Available Primate facial expressions are widely accepted as underpinned by reflexive emotional processes and not under voluntary control. In contrast, other modes of primate communication, especially gestures, are widely accepted as underpinned by intentional, goal-driven cognitive processes. One reason for this distinction is that production of primate gestures is often sensitive to the attentional state of the recipient, a phenomenon used as one of the key behavioural criteria for identifying intentionality in signal production. The reasoning is that modifying/producing a signal when a potential recipient is looking could demonstrate that the sender intends to communicate with them. Here, we show that the production of a primate facial expression can also be sensitive to the attention of the play partner. Using the orangutan (Pongo pygmaeus Facial Action Coding System (OrangFACS, we demonstrate that facial movements are more intense and more complex when recipient attention is directed towards the sender. Therefore, production of the playface is not an automated response to play (or simply a play behaviour itself and is instead produced flexibly depending on the context. If sensitivity to attentional stance is a good indicator of intentionality, we must also conclude that the orangutan playface is intentionally produced. However, a number of alternative, lower level interpretations for flexible production of signals in response to the attention of another are discussed. As intentionality is a key feature of human language, claims of intentional communication in related primate species are powerful drivers in language evolution debates, and thus caution in identifying intentionality is important.

  16. A nanobody:GFP bacterial platform that enables functional enzyme display and easy quantification of display capacity.

    Science.gov (United States)

    Wendel, Sofie; Fischer, Emil C; Martínez, Virginia; Seppälä, Susanna; Nørholm, Morten H H

    2016-05-03

    Bacterial surface display is an attractive technique for the production of cell-anchored, functional proteins and engineering of whole-cell catalysts. Although various outer membrane proteins have been used for surface display, an easy and versatile high-throughput-compatible assay for evaluating and developing surface display systems is missing. Using a single domain antibody (also called nanobody) with high affinity for green fluorescent protein (GFP), we constructed a system that allows for fast, fluorescence-based detection of displayed proteins. The outer membrane hybrid protein LppOmpA and the autotransporter C-IgAP exposed the nanobody on the surface of Escherichia coli with very different efficiency. Both anchors were capable of functionally displaying the enzyme Chitinase A as a fusion with the nanobody, and this considerably increased expression levels compared to displaying the nanobody alone. We used flow cytometry to analyse display capability on single-cell versus population level and found that the signal peptide of the anchor has great effect on display efficiency. We have developed an inexpensive and easy read-out assay for surface display using nanobody:GFP interactions. The assay is compatible with the most common fluorescence detection methods, including multi-well plate whole-cell fluorescence detection, SDS-PAGE in-gel fluorescence, microscopy and flow cytometry. We anticipate that the platform will facilitate future in-depth studies on the mechanism of protein transport to the surface of living cells, as well as the optimisation of applications in industrial biotech.

  17. Strategy and your stronger hand.

    Science.gov (United States)

    Moore, Geoffrey A

    2005-12-01

    There are two kinds of businesses in the world, says the author. Knowing what they are--and which one your company is--will guide you to the right strategic moves. One kind includes businesses that compete on a complex-systems model. These companies have large enterprises as their primary customers. They seek to grow a customer base in the thousands, with no more than a handful of transactions per customer per year (indeed, in some years there may be none), and the average price per transaction ranges from six to seven figures. In this model, 1,000 enterprises each paying dollar 1 million per year would generate dollar 1 billion in annual revenue. The other kind of business competes on a volume-operations model. Here, vendors seek to acquire millions of customers, with tens or even hundreds of transactions per customer per year, at an average price of relatively few dollars per transaction. Under this model, it would take 10 million customers each spending dollar 8 per month to generate nearly dollar 1 billion in revenue. An examination of both models shows that they could not be further apart in their approach to every step along the classic value chain. The problem, though, is that companies in one camp often attempt to create new value by venturing into the other. In doing so, they fail to realize how their managerial habits have been shaped by the model they've grown up with. By analogy, they have a "handedness"--the equivalent of a person's right- or left-hand dominance--that makes them as adroit in one mode as they are awkward in the other. Unless you are in an industry whose structure forces you to attempt ambidexterity (in which case, special efforts are required to manage the inevitable dropped balls), you'll be far more successful making moves that favor your stronger hand.

  18. Conceptual Design of Industrial Process Displays

    DEFF Research Database (Denmark)

    Pedersen, C.R.; Lind, Morten

    1999-01-01

    discusses aspects of process display design taking into account both the designer's and the operator's points of view. Three aspects are emphasized: the operator tasks, the display content and the display form. The distinction between these three aspects is the basis for proposing an outline for a display......Today, process displays used in industry are often designed on the basis of piping and instrumentation diagrams without any method of ensuring that the needs of the operators are fulfilled. Therefore, a method for a systematic approach to the design of process displays is needed. This paper...... by a simple example from a plant with batch processes. Later the method is applied to develop a supervisory display for a condenser system in a nuclear power plant. The differences between the continuous plant domain of power production and the batch processes from the example are analysed and broad...

  19. A configural dominant account of contextual cueing : configural cues are stronger than colour cues

    OpenAIRE

    Kunar, Melina A.; Johnston, Rebecca; Sweetman, Hollie

    2013-01-01

    Previous work has shown that reaction times to find a target in displays that have been repeated are faster than those for displays that have never been seen before. This learning effect, termed “contextual cueing” (CC), has been shown using contexts such as the configuration of the distractors in the display and the background colour. However, it is not clear how these two contexts interact to facilitate search. We investigated this here by comparing the strengths of these two cues when they...

  20. Improvements in data display

    International Nuclear Information System (INIS)

    Ellis, G.W.

    1979-01-01

    An analog signal processor is described in this patent for connecting a source of analog signals to a cathode ray tube display in order to extend the dynamic range of the display. This has important applications in the field of computerised X-ray tomography since significant medical information, such as tumours in soft tissue, is often represented by minimal level changes in image density. Cathode ray tube displays are limited to approximately 15 intensity levels. Thus if both strong and weak absorption of the X-rays occurs, the dynamic range of the transmitted signals will be too large to permit small variations to be examined directly on a cathode ray display. Present tomographic image reconstruction methods are capable of quantising X-ray absorption density measurements into 256 or more distinct levels and a description is given of the electronics which enables the upper and lower range of intensity levels to be independently set and continuously varied. (UK)

  1. Helmet-Mounted Display Design Guide

    Science.gov (United States)

    1997-11-03

    on openStack create menu "CSHMD" set the menuitems of "CSHMD" to "(Main Menu; References;-; Definitions;Display Criteria;Display Formats;Display Modes...34Macintosh" then put ":" into dirSep else put "V’ into dirSep put stackPathO&"Resource"&dirSep into gResPath put 0 into gXRef end openStack on

  2. Ruggedized Full-Color Flexible OLED Display

    National Research Council Canada - National Science Library

    Hack, Michael

    2003-01-01

    .... The team comprised Universal Display Corporation, Princeton University, the University of Southern California, Penn State University, L3 Displays and Vitex Systems, and was led by Universal Display Corporation (PI: Michael Hack...

  3. Understanding the exposure-time effect on speckle contrast measurements for laser displays

    Science.gov (United States)

    Suzuki, Koji; Kubota, Shigeo

    2018-02-01

    To evaluate the influence of exposure time on speckle noise for laser displays, speckle contrast measurement method was developed observable at a human eye response time using a high-sensitivity camera which has a signal multiplying function. The nonlinearity of camera light sensitivity was calibrated to measure accurate speckle contrasts, and the measuring lower limit noise of speckle contrast was improved by applying spatial-frequency low pass filter to the captured images. Three commercially available laser displays were measured over a wide range of exposure times from tens of milliseconds to several seconds without adjusting the brightness of laser displays. The speckle contrast of raster-scanned mobile projector without any speckle-reduction device was nearly constant over various exposure times. On the contrary to this, in full-frame projection type laser displays equipped with a temporally-averaging speckle-reduction device, some of their speckle contrasts close to the lower limits noise were slightly increased at the shorter exposure time due to the noise. As a result, the exposure-time effect of speckle contrast could not be observed in our measurements, although it is more reasonable to think that the speckle contrasts of laser displays, which are equipped with the temporally-averaging speckle-reduction device, are dependent on the exposure time. This discrepancy may be attributed to the underestimation of temporal averaging factor. We expected that this method is useful for evaluating various laser displays and clarify the relationship between the speckle noise and the exposure time for a further verification of speckle reduction.

  4. Resolution and noise measurements of five CRT and LCD medical displays

    International Nuclear Information System (INIS)

    Saunders, Robert S. Jr.; Samei, Ehsan

    2006-01-01

    The performance of soft-copy displays plays a significant role in the overall image quality of a digital radiographic system. In this work, we discuss methods to characterize the resolution and noise of both cathode ray tube (CRT) and liquid crystal display (LCD) devices. We measured the image quality of five different commercial display devices, representing both CRT and LCD technologies, using a high-quality charge-coupled device (CCD) camera. The modulation transfer function (MTF) was calculated using the line technique, correcting for the MTF of the CCD camera and the display pixel size. The normalized noise power spectrum (NPS) was computed from two-dimensional Fourier analysis of uniform images. To separate the effects of pixel structure from interpixel luminance variations, we created structure-free images by eliminating the pixel structures of the display device. The NPS was then computed from these structure-free images to isolate interpixel luminance variations. We found that the MTF of LCDs remained close to the theoretical limit dictated by their inherent pixel size (0.85±0.08 at Nyquist frequency), in contrast to the MTF for the two CRT displays, which dropped to 0.15±0.08 at the Nyquist frequency. However, the NPS of LCDs showed significant peaks due to the subpixel structure, while the NPS of CRT displays exhibited a nearly flat power spectrum. After removing the pixel structure, the structured noise peaks for LCDs were eliminated and the overall noise magnitude was significantly reduced. The average total noise-to-signal ratio for CRT displays was 6.55%±0.59%, of which 6.03%±0.24% was due to interpixel luminance variations, while LCD displays had total noise to signal ratios of 46.1%±5.1% of which 1.50%±0.41% were due to interpixel luminance variations. Depending on the extent of the blurring and prewhitening processes of the human visual system, the magnitude of the display noise (including pixel structure) potentially perceived by the

  5. A variable-collimation display system

    Science.gov (United States)

    Batchko, Robert; Robinson, Sam; Schmidt, Jack; Graniela, Benito

    2014-03-01

    Two important human depth cues are accommodation and vergence. Normally, the eyes accommodate and converge or diverge in tandem; changes in viewing distance cause the eyes to simultaneously adjust both focus and orientation. However, ambiguity between accommodation and vergence cues is a well-known limitation in many stereoscopic display technologies. This limitation also arises in state-of-the-art full-flight simulator displays. In current full-flight simulators, the out-the-window (OTW) display (i.e., the front cockpit window display) employs a fixed collimated display technology which allows the pilot and copilot to perceive the OTW training scene without angular errors or distortions; however, accommodation and vergence cues are limited to fixed ranges (e.g., ~ 20 m). While this approach works well for long-range, the ambiguity of depth cues at shorter range hinders the pilot's ability to gauge distances in critical maneuvers such as vertical take-off and landing (VTOL). This is the first in a series of papers on a novel, variable-collimation display (VCD) technology that is being developed under NAVY SBIR Topic N121-041 funding. The proposed VCD will integrate with rotary-wing and vertical take-off and landing simulators and provide accurate accommodation and vergence cues for distances ranging from approximately 3 m outside the chin window to ~ 20 m. A display that offers dynamic accommodation and vergence could improve pilot safety and training, and impact other applications presently limited by lack of these depth cues.

  6. Combat vehicle crew helmet-mounted display: next generation high-resolution head-mounted display

    Science.gov (United States)

    Nelson, Scott A.

    1994-06-01

    The Combat Vehicle Crew Head-Mounted Display (CVC HMD) program is an ARPA-funded, US Army Natick Research, Development, and Engineering Center monitored effort to develop a high resolution, flat panel HMD for the M1 A2 Abrams main battle tank. CVC HMD is part of the ARPA High Definition Systems (HDS) thrust to develop and integrate small (24 micrometers square pels), high resolution (1280 X 1024 X 6-bit grey scale at 60 frame/sec) active matrix electroluminescent (AMEL) and active matrix liquid crystal displays (AMLCD) for head mounted and projection applications. The Honeywell designed CVC HMD is a next generation head-mounted display system that includes advanced flat panel image sources, advanced digital display driver electronics, high speed (> 1 Gbps) digital interconnect electronics, and light weight, high performance optical and mechanical designs. The resulting dramatic improvements in size, weight, power, and cost have already led to program spin offs for both military and commercial applications.

  7. Basics of Antibody Phage Display Technology.

    Science.gov (United States)

    Ledsgaard, Line; Kilstrup, Mogens; Karatt-Vellatt, Aneesh; McCafferty, John; Laustsen, Andreas H

    2018-06-09

    Antibody discovery has become increasingly important in almost all areas of modern medicine. Different antibody discovery approaches exist, but one that has gained increasing interest in the field of toxinology and antivenom research is phage display technology. In this review, the lifecycle of the M13 phage and the basics of phage display technology are presented together with important factors influencing the success rates of phage display experiments. Moreover, the pros and cons of different antigen display methods and the use of naïve versus immunized phage display antibody libraries is discussed, and selected examples from the field of antivenom research are highlighted. This review thus provides in-depth knowledge on the principles and use of phage display technology with a special focus on discovery of antibodies that target animal toxins.

  8. Three-dimensional hologram display system

    Science.gov (United States)

    Mintz, Frederick (Inventor); Chao, Tien-Hsin (Inventor); Bryant, Nevin (Inventor); Tsou, Peter (Inventor)

    2009-01-01

    The present invention relates to a three-dimensional (3D) hologram display system. The 3D hologram display system includes a projector device for projecting an image upon a display medium to form a 3D hologram. The 3D hologram is formed such that a viewer can view the holographic image from multiple angles up to 360 degrees. Multiple display media are described, namely a spinning diffusive screen, a circular diffuser screen, and an aerogel. The spinning diffusive screen utilizes spatial light modulators to control the image such that the 3D image is displayed on the rotating screen in a time-multiplexing manner. The circular diffuser screen includes multiple, simultaneously-operated projectors to project the image onto the circular diffuser screen from a plurality of locations, thereby forming the 3D image. The aerogel can use the projection device described as applicable to either the spinning diffusive screen or the circular diffuser screen.

  9. Display rules versus display autonomy: emotion regulation, emotional exhaustion, and task performance in a call center simulation.

    Science.gov (United States)

    Goldberg, Lori Sideman; Grandey, Alicia A

    2007-07-01

    "Service with a smile" is satisfying for the customer, but such display rules may be costly to the employee and the organization. Most previous research on such costs has used self-reported and cross-sectional designs. The authors use an experimental approach to test tenets of resource depletion theories; specifically, whether the self-regulation of emotions required by display rules depletes energy and attentional resources during a service encounter. Using a call center simulation with three "customer" interactions, the authors found that participants given positive display rules (e.g., be enthusiastic and hide frustration) reported more postsimulation exhaustion and made more errors on the order form compared to those with display autonomy. Customer hostility during one of the calls also increased exhaustion overall and the number of errors during that specific call, though proposed interactions with display rules were not supported. Surface-level emotion regulation, but not deep-level, was the mechanism for the energy depletion effect of display rules, while display rules had a direct effect on performance decrements. Theoretical and practical implications for display rules as part of job requirements are discussed. Copyright 2007 APA

  10. Sexual harassment and emotional and behavioural symptoms in adolescence: stronger associations among boys than girls.

    Science.gov (United States)

    Kaltiala-Heino, Riittakerttu; Fröjd, Sari; Marttunen, Mauri

    2016-08-01

    To study the associations between subjection to sexual harassment and emotional (depression) and behavioural (delinquency) symptoms among 14-to-18-year-old adolescents, and gender differences within these associations. 90,953 boys and 91,746 girls aged 14-18 participated in the School Health Promotion Study (SHPS), a school-based survey designed to examine the health, health behaviours, and school experiences of teenagers. Experiences of sexual harassment were elicited with five questions addressing five separate forms of harassment. Depression was measured by the 13-item Beck Depression Inventory and delinquency with a modified version of the International Self-Report Delinquency Study (ISRD) instrument. Data were analysed using cross-tabulations with Chi-square statistics and logistic regression. All sexual harassment experiences studied were associated with both depression (adjusted odds ratios varied from 2.2 to 2.7 in girls and from 2.0 to 5.1 in boys) and delinquency (adjusted odds ratios 3.1-5.0 in girls and 1.7-6.9 in boys). Sexual name-calling had a stronger association with depression and with delinquency in girls (adjusted odds ratios, respectively, 2.4 and 4.2), than in boys (adjusted odds ratios, respectively, 2.0 and 1.7), but otherwise stronger associations with emotional and behavioural symptoms were seen in boys. Subjection to sexual harassment is associated with both emotional and behavioural symptoms in both girls and boys. The associations are mostly stronger for boys. Boys subjected to sexual harassment may feel particularly threatened regarding their masculinity, and there may be less support available for boys traumatised due to sexual harassment.

  11. Paediatric dose display

    International Nuclear Information System (INIS)

    Griffin, D.W.; Derges, S.; Hesslewood, S.

    1984-01-01

    A compact, inexpensive unit, based on an 8085 microprocessor, has been designed for calculating doses of intravenous radioactive injections for children. It has been used successfully for over a year. The dose is calculated from the body surface area and the result displayed in MBq. The operator can obtain the required dose on a twelve character alphanumeric display by entering the age of the patient and the adult dose using a hexadecimal keyboard. Circuit description, memory map and input/output, and firmware are dealt with. (U.K.)

  12. Scaling Robotic Displays: Displays and Techniques for Dismounted Movement with Robots

    Science.gov (United States)

    2010-04-01

    you are performing the low crawl 4.25 5.00 Drive the robot while you are negotiating the hill 6.00 5.00 Drive the robot while you are climbing the... stairs 4.67 5.00 Drive the robot while you are walking 5.70 5.27 HMD It was fairly doable. 1 When you’re looking through the lens, it’s not...Scaling Robotic Displays: Displays and Techniques for Dismounted Movement with Robots by Elizabeth S. Redden, Rodger A. Pettitt

  13. Display rules for anger, sadness, and pain: it depends on who is watching.

    Science.gov (United States)

    Zeman, J; Garber, J

    1996-06-01

    This study examined factors that may influence children's decisions to control or express their emotions including type of emotion (anger, sadness, physical pain), type of audience (mother, father, peer, alone), age, and sex. Children's reported use of display rules, reasons for their decisions, and reported method of expression were examined. Subjects were 32 boys and 32 girls in each of the first (M = 7.25 years old), third (M = 9.33 years old), and fifth grades (M = 11.75 years old). Regardless of the type of emotion experienced, children reported controlling their expression of emotion significantly more in the presence of peers than when they were with either their mother or father or when they were alone. Younger children reported expressing sadness and anger significantly more often than did older children, and girls were more likely than boys to report expressing sadness and pain. Children's primary reason for controlling their emotional expressions was the expectation of a negative interpersonal interaction following disclosure.

  14. Liquid crystal displays with plastic substrates

    Science.gov (United States)

    Lueder, Ernst H.

    1998-04-01

    Plastic substrates for the cells of displays exhibit only 1/6 of the weight of glass substrates; they are virtually unbreakable; their flexibility allows the designer to give them a shape suppressing reflections, to realize a display board on a curved surface or meeting the requirements for an appealing styling; displays with plastics are thinner which provides a wider viewing angle. These features render them attractive for displays in portable systems such as mobile phones, pagers, smart cards, personal digital assistants (PDAs) and portable computers. Reflective displays are especially attractive as they don't need a back light. The most important requirements are the protection of plastics against gas permeation and chemical agents, the prevention of layers on plastics to crack or peel off when the plastic is bent and the development of low temperature thin film processes because the plastics, as a rule, only tolerate temperatures below 150 degrees Celsius. Bistable reflective FLC- and PSCT-displays with plastic substrates will be introduced. Special sputtered SiO2-orientation layers preserve the displayed information even if pressure or torsion is applied. MIM-addressed PDLC-displays require additional Al- or Ti-layers which provide the necessary ductility. Sputtered or PECVD-generated TFTs can be fabricated on plastics at temperatures below 150 degrees Celsius.

  15. A full-parallax 3D display with restricted viewing zone tracking viewer's eye

    Science.gov (United States)

    Beppu, Naoto; Yendo, Tomohiro

    2015-03-01

    The Three-Dimensional (3D) vision became widely known as familiar imaging technique now. The 3D display has been put into practical use in various fields, such as entertainment and medical fields. Development of 3D display technology will play an important role in a wide range of fields. There are various ways to the method of displaying 3D image. There is one of the methods that showing 3D image method to use the ray reproduction and we focused on it. This method needs many viewpoint images when achieve a full-parallax because this method display different viewpoint image depending on the viewpoint. We proposed to reduce wasteful rays by limiting projector's ray emitted to around only viewer using a spinning mirror, and to increase effectiveness of display device to achieve a full-parallax 3D display. We propose a method by using a tracking viewer's eye, a high-speed projector, a rotating mirror that tracking viewer (a spinning mirror), a concave mirror array having the different vertical slope arranged circumferentially (a concave mirror array), a cylindrical mirror. About proposed method in simulation, we confirmed the scanning range and the locus of the movement in the horizontal direction of the ray. In addition, we confirmed the switching of the viewpoints and convergence performance in the vertical direction of rays. Therefore, we confirmed that it is possible to realize a full-parallax.

  16. Plant state display device

    International Nuclear Information System (INIS)

    Kadota, Kazuo; Ito, Toshiichiro.

    1994-01-01

    The device of the present invention conducts information processing suitable for a man to solve a problem in a plant such as a nuclear power plant incorporating a great amount of information, where safety is required and provides information to an operator. Namely, theories and rules with respect to the flow and balanced state of materials and energy upon plant start-up, and a vapor cycle of operation fluids are symbolized and displayed on the display screen of the device. Then, the display of the plant information suitable to the information processing for a man to dissolve problems is provided. Accordingly, a mechanism for analyzing a purpose of the plant is made more definite, thereby enabling to prevent an erroneous judgement of an operator and occurrence of plant troubles. In addition, a simular effect can also be expected when the theories and rules with respect to the flow and the balanced state of materials and energy and thermohydrodynamic behavior of the operation fluids in a state of after-heat removing operation during shutdown of the plant are symbolized and displayed. (I.S.)

  17. Dependence on zenith angle of the strength of 3-meter equatorial electrojet irregularities

    International Nuclear Information System (INIS)

    Ierkic, H.M.; Fejer, B.G.; Farley, D.T.

    1980-01-01

    Radar measurements in Peru were used to deduce the zenith angle dependence of the scattering cross section of plasma irregularities generated by instabilities in the equatorial electrojet. The irregularities probed by the 50 MHz Jicamarca radar had a wavelength of 3m. The cross section for the type 2 irregularities was isotopic in the plane perpendicular to the magnetic field, while the cross section for the stronger type 1 irregularities varied with zenith angle at a rate of approximately 0.3 dB/degree; the horizontally traveling waves were more than 100 times stronger than those traveling vertically

  18. Thermodynamic studies of a series of homologous HIV-1 TAR RNA ligands reveal that loose binders are stronger Tat competitors than tight ones.

    Science.gov (United States)

    Pascale, Lise; Azoulay, Stéphane; Di Giorgio, Audrey; Zenacker, Laura; Gaysinski, Marc; Clayette, Pascal; Patino, Nadia

    2013-06-01

    RNA is a major drug target, but the design of small molecules that modulate RNA function remains a great challenge. In this context, a series of structurally homologous 'polyamide amino acids' (PAA) was studied as HIV-1 trans-activating response (TAR) RNA ligands. An extensive thermodynamic study revealed the occurence of an enthalpy-entropy compensation phenomenon resulting in very close TAR affinities for all PAA. However, their binding modes and their ability to compete with the Tat fragment strongly differ according to their structure. Surprisingly, PAA that form loose complexes with TAR were shown to be stronger Tat competitors than those forming tight ones, and thermal denaturation studies demonstrated that loose complexes are more stable than tight ones. This could be correlated to the fact that loose and tight ligands induce distinct RNA conformational changes as revealed by circular dichroism experiments, although nuclear magnetic resonance (NMR) experiments showed that the TAR binding site is the same in all cases. Finally, some loose PAA also display promising inhibitory activities on HIV-infected cells. Altogether, these results lead to a better understanding of RNA interaction modes that could be very useful for devising new ligands of relevant RNA targets.

  19. Dependence of Glass Mechanical Properties on Thermal and Pressure History

    DEFF Research Database (Denmark)

    Smedskjær, Morten Mattrup; Bauchy, Mathieu

    Predicting the properties of new glasses prior to manufacturing is a topic attracting great industrial and scientific interest. Mechanical properties are currently of particular interest given the increasing demand for stronger, thinner, and more flexible glasses in recent years. However, as a non......-equilibrium material, the structure and properties of glass depend not only on its composition, but also on its thermal and pressure histories. Here we review our recent findings regarding the thermal and pressure history dependence of indentation-derived mechanical properties of oxide glasses....

  20. Color speckle in laser displays

    Science.gov (United States)

    Kuroda, Kazuo

    2015-07-01

    At the beginning of this century, lighting technology has been shifted from discharge lamps, fluorescent lamps and electric bulbs to solid-state lighting. Current solid-state lighting is based on the light emitting diodes (LED) technology, but the laser lighting technology is developing rapidly, such as, laser cinema projectors, laser TVs, laser head-up displays, laser head mounted displays, and laser headlamps for motor vehicles. One of the main issues of laser displays is the reduction of speckle noise1). For the monochromatic laser light, speckle is random interference pattern on the image plane (retina for human observer). For laser displays, RGB (red-green-blue) lasers form speckle patterns independently, which results in random distribution of chromaticity, called color speckle2).

  1. Development of Real-Time Dual-Display Handheld and Bench-Top Hybrid-Mode SD-OCTs

    Directory of Open Access Journals (Sweden)

    Nam Hyun Cho

    2014-01-01

    Full Text Available Development of a dual-display handheld optical coherence tomography (OCT system for retina and optic-nerve-head diagnosis beyond the volunteer motion constraints is reported. The developed system is portable and easily movable, containing the compact portable OCT system that includes the handheld probe and computer. Eye posterior chambers were diagnosed using the handheld probe, and the probe could be fixed to the bench-top cradle depending on the volunteers’ physical condition. The images obtained using this handheld probe were displayed in real time on the computer monitor and on a small secondary built-in monitor; the displayed images were saved using the handheld probe’s built-in button. Large-scale signal-processing procedures such as k-domain linearization, fast Fourier transform (FFT, and log-scaling signal processing can be rapidly applied using graphics-processing-unit (GPU accelerated processing rather than central-processing-unit (CPU processing. The Labview-based system resolution is 1,024 × 512 pixels, and the frame rate is 56 frames/s, useful for real-time display. The 3D images of the posterior chambers including the retina, optic-nerve head, blood vessels, and optic nerve were composed using real-time displayed images with 500 × 500 × 500 pixel resolution. A handheld and bench-top hybrid mode with a dual-display handheld OCT was developed to overcome the drawbacks of the conventional method.

  2. An integrated vendor-buyer model with stock-dependent demand

    DEFF Research Database (Denmark)

    Sajadieh, Mohsen S.; Thorstenson, Anders; Akbari Jokar, Mohammad R.

    in a display area. The end-customer demand is assumed to be positively dependent on the amount of items shown in the display area. With the proposed model we determine the buyer's optimal shipment quantity and number of shipments, as well as the vendor's optimal production batch. The objective is to maximize...... total supply chain profit. The numerical analysis shows that it is more profitable for the buyer and the vendor to cooperate in situations when the demand is more stock-dependent. The analysis also shows the effect of double marginalization in this integrated vendor-buyer model....

  3. An integrated vendor-buyer model with stock-dependent demand

    DEFF Research Database (Denmark)

    Sajadieh, Mohsen S.; Thorstenson, Anders; Akbari Jokar, Mohammad R.

    2010-01-01

    We develop an integrated vendor-buyer model for a two-stage supply chain. The vendor manufactures the product and delivers it in a number of equal-sized batches to the buyer. The items delivered are presented to the end customers in a display area. Demand is assumed to be positively dependent...... on the amount of items displayed. The objective is to maximize total supply chain profit. The numerical analysis shows that buyer-vendor coordination is more profitable in situations when demand is more stock dependent. It also shows that the effect of double marginalization provides a link between the non...

  4. An Integrated Vendor-Buyer Model with Stock-Dependent Demand

    DEFF Research Database (Denmark)

    Thorstenson, Anders; Sajadieh, Mohsen S.; Akbari Jokar, Mohammad R.

    2009-01-01

    in the buyer's warehouse. The demand is assumed to be positively dependent on the amount of items shown in the display area. The proposed model determines the buyer's optimal shipment quantity and number of shipments, as well as the vendor's optimal production batch. The objective is to maximize total supply......-chain profit. The numerical analysis shows that as long as the maximum display area is not used, it is more valuable for the buyer and the vendor to cooperate in situations when the demand is more stock- dependent. It also shows the effect of double marginalization in this integrated vendor-buyer model....

  5. Three-dimensional Imaging, Visualization, and Display

    CERN Document Server

    Javidi, Bahram; Son, Jung-Young

    2009-01-01

    Three-Dimensional Imaging, Visualization, and Display describes recent developments, as well as the prospects and challenges facing 3D imaging, visualization, and display systems and devices. With the rapid advances in electronics, hardware, and software, 3D imaging techniques can now be implemented with commercially available components and can be used for many applications. This volume discusses the state-of-the-art in 3D display and visualization technologies, including binocular, multi-view, holographic, and image reproduction and capture techniques. It also covers 3D optical systems, 3D display instruments, 3D imaging applications, and details several attractive methods for producing 3D moving pictures. This book integrates the background material with new advances and applications in the field, and the available online supplement will include full color videos of 3D display systems. Three-Dimensional Imaging, Visualization, and Display is suitable for electrical engineers, computer scientists, optical e...

  6. Language experience enhances early cortical pitch-dependent responses

    Science.gov (United States)

    Krishnan, Ananthanarayan; Gandour, Jackson T.; Ananthakrishnan, Saradha; Vijayaraghavan, Venkatakrishnan

    2014-01-01

    Pitch processing at cortical and subcortical stages of processing is shaped by language experience. We recently demonstrated that specific components of the cortical pitch response (CPR) index the more rapidly-changing portions of the high rising Tone 2 of Mandarin Chinese, in addition to marking pitch onset and sound offset. In this study, we examine how language experience (Mandarin vs. English) shapes the processing of different temporal attributes of pitch reflected in the CPR components using stimuli representative of within-category variants of Tone 2. Results showed that the magnitude of CPR components (Na-Pb and Pb-Nb) and the correlation between these two components and pitch acceleration were stronger for the Chinese listeners compared to English listeners for stimuli that fell within the range of Tone 2 citation forms. Discriminant function analysis revealed that the Na-Pb component was more than twice as important as Pb-Nb in grouping listeners by language affiliation. In addition, a stronger stimulus-dependent, rightward asymmetry was observed for the Chinese group at the temporal, but not frontal, electrode sites. This finding may reflect selective recruitment of experience-dependent, pitch-specific mechanisms in right auditory cortex to extract more complex, time-varying pitch patterns. Taken together, these findings suggest that long-term language experience shapes early sensory level processing of pitch in the auditory cortex, and that the sensitivity of the CPR may vary depending on the relative linguistic importance of specific temporal attributes of dynamic pitch. PMID:25506127

  7. Integrated multimodal human-computer interface and augmented reality for interactive display applications

    Science.gov (United States)

    Vassiliou, Marius S.; Sundareswaran, Venkataraman; Chen, S.; Behringer, Reinhold; Tam, Clement K.; Chan, M.; Bangayan, Phil T.; McGee, Joshua H.

    2000-08-01

    We describe new systems for improved integrated multimodal human-computer interaction and augmented reality for a diverse array of applications, including future advanced cockpits, tactical operations centers, and others. We have developed an integrated display system featuring: speech recognition of multiple concurrent users equipped with both standard air- coupled microphones and novel throat-coupled sensors (developed at Army Research Labs for increased noise immunity); lip reading for improving speech recognition accuracy in noisy environments, three-dimensional spatialized audio for improved display of warnings, alerts, and other information; wireless, coordinated handheld-PC control of a large display; real-time display of data and inferences from wireless integrated networked sensors with on-board signal processing and discrimination; gesture control with disambiguated point-and-speak capability; head- and eye- tracking coupled with speech recognition for 'look-and-speak' interaction; and integrated tetherless augmented reality on a wearable computer. The various interaction modalities (speech recognition, 3D audio, eyetracking, etc.) are implemented a 'modality servers' in an Internet-based client-server architecture. Each modality server encapsulates and exposes commercial and research software packages, presenting a socket network interface that is abstracted to a high-level interface, minimizing both vendor dependencies and required changes on the client side as the server's technology improves.

  8. When authenticity matters most: Physicians' regulation of emotional display and patient satisfaction.

    Science.gov (United States)

    Yagil, Dana; Shnapper-Cohen, Moran

    2016-10-01

    The emotions expressed by physicians in medical encounters have significant impact on health outcomes and patient satisfaction. This study explored how physicians' regulation of displayed emotions affects patients' satisfaction, under low and high levels of patient distress and length of physician-patient acquaintance. Questionnaires were administered to 46 physicians and 230 of their patients (before and after the medical encounter) in outpatient clinics of two hospitals. Data were analyzed with hierarchical linear modeling which takes the nested data structure into account. We found a significant interaction effect of physician regulation of displayed emotions and patient distress on satisfaction: When distress was high, physician regulation of emotions was negatively related to patient satisfaction. The results also show a significant interaction effect of physician regulation of displayed emotions and length of physician-patient acquaintance: With a longer acquaintance, physician regulation of emotions was negatively related to patient satisfaction. The effect of the physicians' emotional display on patient satisfaction depends on contextual factors, such as patient distress and length of physician-patient acquaintance, which affect patients' emotional needs and expectations. When patients have high emotional involvement in the encounter it is suggested that physicians consider presenting genuine emotions to patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Performance and Preference with Various VDT (Video Display Terminal) Phosphors

    Science.gov (United States)

    1987-04-24

    aesthetic judgment, but that ignore psycnophysics and task requirements, can degrade visual performance and comfort." The quality of a retinal image depends...K.N, (1961). Poveal contrast thresholds with blurring of the retinal image and increasing size of test stimulus. J. Opt. Soc. Am. 51:862-869. Ohlsson...Van Nes, F.L. (1986). Space, colour and typography on visual display terminals. Behav. and Info, Tech. 5: 99-118. Van Nes, F.L. and Bouman, M.A. (1967

  10. SNS online display technologies for EPICS

    International Nuclear Information System (INIS)

    Kasemir, K.U.; Chen, X.; Purcell, J.; Danilova, E.

    2012-01-01

    The ubiquitousness of web clients from personal computers to cell phones results in a growing demand for web-based access to control system data. At the Oak Ridge National Laboratory Spallation Neutron Source (SNS) we have investigated different technical approaches to provide read access to data in the Experimental Physics and Industrial Control System (EPICS) for a wide variety of web client devices. The core web technology, HTTP, is less than ideal for online control system displays. Appropriate use of Ajax, especially the Long Poll paradigm, can alleviate fundamental HTTP limitations. The SNS Status web uses basic Ajax technology to generate generic displays for a wide audience. The Dashboard uses Long Poll and more client-side Java-Script to offer more customization and faster updates for users that need specialized displays. The Web OPI uses RAP for web access to any BOY display, offering utmost flexibility because users can create their own BOY displays in CSS. These three approaches complement each other. Users can access generic status displays with zero effort, invest time in creating their fully customized displays for the Web OPI, or use the Dashboard as an intermediate solution

  11. Dyes for displays

    Science.gov (United States)

    Claussen, U.

    1984-01-01

    The improvement of contrast and visibility of LCD by two different means was undertaken. The two methods are: (1) development of fluorescent dyes to increase the visibility of fluorescent activated displays (FLAD); and (2) development of dichroic dyes to increase the contrast of displays. This work was done in close cooperation with the electronic industry, where the newly synthesized dyes were tested. The targets for the chemical synthesis were selected with the help of computer model calculations. A marketable range of dyes was developed. Since the interest of the electronic industries concerning FLAD was low, the investigations were stopped. Dichroic dyes, especially black mixtures with good light fastness, order parameter, and solubility in nematic phases were developed. The application of these dyes is restricted to indoor use because of an increase of viscosity below -10 C. Applications on a technical scale, e.g., for the automotive industry, will be possible if the displays work at temperatures down to -40 C. This problem requires a complex optimization of the dye/nematic phase system.

  12. Flat panel planar optic display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T. [Brookhaven National Lab., Upton, NY (United States). Dept. of Advanced Technology

    1994-11-01

    A prototype 10 inch flat panel Planar Optic Display, (POD), screen has been constructed and tested. This display screen is comprised of hundreds of planar optic class sheets bonded together with a cladding layer between each sheet where each glass sheet represents a vertical line of resolution. The display is 9 inches wide by 5 inches high and approximately 1 inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  13. Extreme-value dependence: An application to exchange rate markets

    Science.gov (United States)

    Fernandez, Viviana

    2007-04-01

    Extreme value theory (EVT) focuses on modeling the tail behavior of a loss distribution using only extreme values rather than the whole data set. For a sample of 10 countries with dirty/free float regimes, we investigate whether paired currencies exhibit a pattern of asymptotic dependence. That is, whether an extremely large appreciation or depreciation in the nominal exchange rate of one country might transmit to another. In general, after controlling for volatility clustering and inertia in returns, we do not find evidence of extreme-value dependence between paired exchange rates. However, for asymptotic-independent paired returns, we find that tail dependency of exchange rates is stronger under large appreciations than under large depreciations.

  14. M2e-displaying virus-like particles with associated RNA promote T helper 1 type adaptive immunity against influenza A.

    Directory of Open Access Journals (Sweden)

    Lorena Itatí Ibañez

    Full Text Available The ectodomain of influenza A matrix protein 2 (M2e is a candidate for a universal influenza A vaccine. We used recombinant Hepatitis B core antigen to produce virus-like particles presenting M2e (M2e-VLPs. We produced the VLPs with and without entrapped nucleic acids and compared their immunogenicity and protective efficacy. Immunization of BALB/c mice with M2e-VLPs containing nucleic acids induced a stronger, Th1-biased antibody response compared to particles lacking nucleic acids. The former also induced a stronger M2e-specific CD4(+ T cell response, as determined by ELISPOT. Mice vaccinated with alum-adjuvanted M2e-VLPs containing the nucleic acid-binding domain were better protected against influenza A virus challenge than mice vaccinated with similar particles lacking this domain, as deduced from the loss in body weight following challenge with X47 (H3N2 or PR/8 virus. Challenge of mice that had been immunized with M2e-VLPs with or without nucleic acids displayed significantly lower mortality, morbidity and lung virus titers than control-immunized groups. We conclude that nucleic acids present in M2e-VLPs correlate with improved immune protection.

  15. Compressive multi-mode superresolution display

    KAUST Repository

    Heide, Felix

    2014-01-01

    Compressive displays are an emerging technology exploring the co-design of new optical device configurations and compressive computation. Previously, research has shown how to improve the dynamic range of displays and facilitate high-quality light field or glasses-free 3D image synthesis. In this paper, we introduce a new multi-mode compressive display architecture that supports switching between 3D and high dynamic range (HDR) modes as well as a new super-resolution mode. The proposed hardware consists of readily-available components and is driven by a novel splitting algorithm that computes the pixel states from a target high-resolution image. In effect, the display pixels present a compressed representation of the target image that is perceived as a single, high resolution image. © 2014 Optical Society of America.

  16. Nuclear image display controller

    International Nuclear Information System (INIS)

    Roth, D.A.

    1985-01-01

    In a nuclear imaging system the digitized x and y coordinates of gamma ray photon emission events address memory locations corresponding to the coordinates. The respective locations are incremented each time they are addressed so at the end of a selected time or event count period the locations contain digital values or raw data corresponding to the intensity of pixels comprising an image frame. The raw data for a frame is coupled to one input of an arithmetic logic unit (ALU) whose output is coupled to a display controller memory. The output of the controller memory is coupled to another ALU input with a feedback bus and is also coupled to a further signal processing circuit which includes means for converting processed data to analog video signals for television display. The ALU is selectively controlled to let raw image data pass through to the display controllor memory or alternately to add (or subtract) raw data for the last image frame developed to the raw data for preceding frames held in the display controller to thereby produce the visual effect on the television screen of an isotope flowing through anatomy

  17. Dimensions of Situatedness for Digital Public Displays

    Directory of Open Access Journals (Sweden)

    Rui José

    2014-01-01

    Full Text Available Public displays are often strongly situated signs deeply embedded in their physical, social, and cultural setting. Understanding how the display is coupled with on-going situations, its level of situatedness, provides a key element for the interpretation of the displays themselves but is also an element for the interpretation of place, its situated practices, and its social context. Most digital displays, however, do not achieve the same sense of situatedness that seems so natural in their nondigital counterparts. This paper investigates people’s perception of situatedness when considering the connection between public displays and their context. We have collected over 300 photos of displays and conducted a set of analysis tasks involving focus groups and structured interviews with 15 participants. The contribution is a consolidated list of situatedness dimensions that should provide a valuable resource for reasoning about situatedness in digital displays and informing the design and development of display systems.

  18. Visual memory performance for color depends on spatiotemporal context.

    Science.gov (United States)

    Olivers, Christian N L; Schreij, Daniel

    2014-10-01

    Performance on visual short-term memory for features has been known to depend on stimulus complexity, spatial layout, and feature context. However, with few exceptions, memory capacity has been measured for abruptly appearing, single-instance displays. In everyday life, objects often have a spatiotemporal history as they or the observer move around. In three experiments, we investigated the effect of spatiotemporal history on explicit memory for color. Observers saw a memory display emerge from behind a wall, after which it disappeared again. The test display then emerged from either the same side as the memory display or the opposite side. In the first two experiments, memory improved for intermediate set sizes when the test display emerged in the same way as the memory display. A third experiment then showed that the benefit was tied to the original motion trajectory and not to the display object per se. The results indicate that memory for color is embedded in a richer episodic context that includes the spatiotemporal history of the display.

  19. On-line data display

    Science.gov (United States)

    Lang, Sherman Y. T.; Brooks, Martin; Gauthier, Marc; Wein, Marceli

    1993-05-01

    A data display system for embedded realtime systems has been developed for use as an operator's user interface and debugging tool. The motivation for development of the On-Line Data Display (ODD) have come from several sources. In particular the design reflects the needs of researchers developing an experimental mobile robot within our laboratory. A proliferation of specialized user interfaces revealed a need for a flexible communications and graphical data display system. At the same time the system had to be readily extensible for arbitrary graphical display formats which would be required for data visualization needs of the researchers. The system defines a communication protocol transmitting 'datagrams' between tasks executing on the realtime system and virtual devices displaying the data in a meaningful way on a graphical workstation. The communication protocol multiplexes logical channels on a single data stream. The current implementation consists of a server for the Harmony realtime operating system and an application written for the Macintosh computer. Flexibility requirements resulted in a highly modular server design, and a layered modular object- oriented design for the Macintosh part of the system. Users assign data types to specific channels at run time. Then devices are instantiated by the user and connected to channels to receive datagrams. The current suite of device types do not provide enough functionality for most users' specialized needs. Instead the system design allows the creation of new device types with modest programming effort. The protocol, design and use of the system are discussed.

  20. Flexible displays, rigid designs?

    DEFF Research Database (Denmark)

    Hornbæk, Kasper

    2015-01-01

    Rapid technological progress has enabled a wide range of flexible displays for computing devices, but the user experience--which we're only beginning to understand--will be the key driver for successful designs.......Rapid technological progress has enabled a wide range of flexible displays for computing devices, but the user experience--which we're only beginning to understand--will be the key driver for successful designs....

  1. Microencapsulated Electrophoretic Films for Electronic Paper Displays

    Science.gov (United States)

    Amundson, Karl

    2003-03-01

    Despite the dominance of liquid crystal displays, they do not perform some functions very well. While backlit liquid crystal displays can offer excellent color performance, they wash out in bright lighting and suffer from high power consumption. Reflective liquid crystal displays have limited brightness, making these devices challenging to read for long periods of time. Flexible liquid crystal displays are difficult to manufacture and keep stable. All of these attributes (long battery lifetime, bright reflective appearance, compatibility with flexible substrates) are traits that would be found in an ideal electronic paper display - an updateable substitute for paper that could be employed in electronic books, newspapers, and other applications. I will discuss technologies that are being developed for electronic-paper-like displays, and especially on particle-based technologies. A microencapsulated electrophoretic display technology is being developed at the E Ink corporation. This display film offers offer high brightness and an ink-on-paper appearance, compatibility with flexible substrates, and image stability that can lead to very low power consumption. I will present some of the physical and chemical challenges associated with making display films with high performance.

  2. Establishment of the method of surface shaded display for brain PET imaging

    International Nuclear Information System (INIS)

    Zhang Xiangsong; Tang Anwu; He Zuoxiang

    2003-01-01

    Objective: To establish the method of surface shaded display (SSD) for brain PET imaging. Methods: The original brain PET images volume data were transferred to the personal computer by the local area network, and scaled into 256 grayscale values between 0 and 255. An appropriate threshold could be selected with three differential methods: depended on the histogram or maximum percentage of the volume data and the opposite value percentage of the lesion. The list of vertices and triangles describing the contour surface was produced with a high resolution three dimensional (3D) surface construction algorithm. Results: The final software of SSD for brain PET imaging with interactive user interface can produce 3D brain PET images which can be rotated, scaled, and saved or outputted with several image formats. Conclusion: The method of SSD for brain PET imaging can directly and integrally reflect the surface of brain cortex, and be helpful to locate lesions and display the range of lesions, but can not reflect the severity of lesions, nor can display the structure under brain cortex

  3. Revisiting the debate on the relationship between display rules and performance: considering the explicitness of display rules.

    Science.gov (United States)

    Christoforou, Paraskevi S; Ashforth, Blake E

    2015-01-01

    We argue that the strength with which the organization communicates expectations regarding the appropriate emotional expression toward customers (i.e., explicitness of display rules) has an inverted U-shaped relationship with service delivery behaviors, customer satisfaction, and sales performance. Further, we argue that service organizations need a particular blend of explicitness of display rules and role discretion for the purpose of optimizing sales performance. As hypothesized, findings from 2 samples of salespeople suggest that either high or low explicitness of display rules impedes service delivery behaviors and sales performance, which peaks at moderate explicitness of display rules and high role discretion. The findings also suggest that the explicitness of display rules has a positive relationship with customer satisfaction. (c) 2015 APA, all rights reserved.

  4. Daytime warming has stronger negative effects on soil nematodes than night-time warming

    OpenAIRE

    Yan, Xiumin; Wang, Kehong; Song, Lihong; Wang, Xuefeng; Wu, Donghui

    2017-01-01

    Warming of the climate system is unequivocal, that is, stronger warming during night-time than during daytime. Here we focus on how soil nematodes respond to the current asymmetric warming. A field infrared heating experiment was performed in the western of the Songnen Plain, Northeast China. Three warming modes, i.e. daytime warming, night-time warming and diurnal warming, were taken to perform the asymmetric warming condition. Our results showed that the daytime and diurnal warming treatmen...

  5. Software for Minsk-32 display station

    International Nuclear Information System (INIS)

    Belyaeva, L.M.; Gangrskaya, O.G.; Manno, I.; Fefilov, B.V.; Ehsenski, J.

    1976-01-01

    The mathematical provision is described of the Minsk-32 display station. Described is the application of editing program DOSE, assembler translator SLANG and program display-focal. Program DOSE permits to edit the texts with the aid of a rester display on Minsk-32 magnetic tape. The program system permits to use a disk monitor system

  6. An Investigation of Interval Management Displays

    Science.gov (United States)

    Swieringa, Kurt A.; Wilson, Sara R.; Shay, Rick

    2015-01-01

    NASA's first Air Traffic Management (ATM) Technology Demonstration (ATD-1) was created to transition the most mature ATM technologies from the laboratory to the National Airspace System. One selected technology is Interval Management (IM), which uses onboard aircraft automation to compute speeds that help the flight crew achieve and maintain precise spacing behind a preceding aircraft. Since ATD-1 focuses on a near-term environment, the ATD-1 flight demonstration prototype requires radio voice communication to issue an IM clearance. Retrofit IM displays will enable pilots to both enter information into the IM avionics and monitor IM operation. These displays could consist of an interface to enter data from an IM clearance and also an auxiliary display that presents critical information in the primary field-of-view. A human-in-the-loop experiment was conducted to examine usability and acceptability of retrofit IM displays, which flight crews found acceptable. Results also indicate the need for salient alerting when new speeds are generated and the desire to have a primary field of view display available that can display text and graphic trend indicators.

  7. Distributed rendering for multiview parallax displays

    Science.gov (United States)

    Annen, T.; Matusik, W.; Pfister, H.; Seidel, H.-P.; Zwicker, M.

    2006-02-01

    3D display technology holds great promise for the future of television, virtual reality, entertainment, and visualization. Multiview parallax displays deliver stereoscopic views without glasses to arbitrary positions within the viewing zone. These systems must include a high-performance and scalable 3D rendering subsystem in order to generate multiple views at real-time frame rates. This paper describes a distributed rendering system for large-scale multiview parallax displays built with a network of PCs, commodity graphics accelerators, multiple projectors, and multiview screens. The main challenge is to render various perspective views of the scene and assign rendering tasks effectively. In this paper we investigate two different approaches: Optical multiplexing for lenticular screens and software multiplexing for parallax-barrier displays. We describe the construction of large-scale multi-projector 3D display systems using lenticular and parallax-barrier technology. We have developed different distributed rendering algorithms using the Chromium stream-processing framework and evaluate the trade-offs and performance bottlenecks. Our results show that Chromium is well suited for interactive rendering on multiview parallax displays.

  8. Cue reactivity is associated with duration and severity of alcohol dependence: an FMRI study.

    Directory of Open Access Journals (Sweden)

    Zsuzsika Sjoerds

    Full Text Available INTRODUCTION: With the progression of substance dependence, drug cue-related brain activation is thought to shift from motivational towards habit pathways. However, a direct association between cue-induced brain activation and dependence duration has not yet been shown. We therefore examined the relationship between alcohol cue-reactivity in the brain, cue-induced subjective craving and alcohol dependence duration and severity. Since alcohol dependence is highly comorbid with depression/anxiety, which may modulate brain responses to alcohol cues, we also examined the relation between comorbid depression/anxiety and cue-reactivity. METHODS: We compared 30 alcohol dependent patients with 15 healthy controls and 15 depression/anxiety patients during a visual alcohol cue-reactivity task using functional magnetic resonance imaging blood oxygenated level-dependent responses and subjective craving as outcomes. Within the alcohol dependent group we correlated cue-reactivity with alcohol dependence severity and duration, with cue-induced craving and with depression/anxiety levels. RESULTS: Alcohol dependent patients showed greater cue-reactivity in motivational brain pathways and stronger subjective craving than depression/anxiety patients and healthy controls. Depression/anxiety was not associated with cue-reactivity, but depression severity in alcohol dependent patients was positively associated with craving. Within alcohol dependence, longer duration of alcohol dependence was associated with stronger cue-related activation of the posterior putamen, a structure involved in habits, whereas higher alcohol dependence severity was associated with lower cue-reactivity in the anterior putamen, an area implicated in goal-directed behavior preceding habit formation. CONCLUSION: Cue-reactivity in alcohol dependence is not modulated by comorbid depression or anxiety. More importantly, the current data confirm the hypothesis of a ventral to dorsal striatal shift

  9. Spielräume schulischer Displays

    Directory of Open Access Journals (Sweden)

    Antje Lehn

    2014-03-01

    Full Text Available Antje Lehn zeigt in ihrem Beitrag, wie durch einen erweiterten Display-Begriff in der Schulklasse durch konkrete Projekte Frontalunterricht unterwandert und das Klassenzimmer zu einem ergebnisoffenen Handlungsraum umgestaltet werden kann. Auch Decken, Spiegel, Tische und Spinde sind Displays ...

  10. A Human Capital Framework for a Stronger Teacher Workforce. Advancing Teaching--Improving Learning. White Paper

    Science.gov (United States)

    Myung, Jeannie; Martinez, Krissia; Nordstrum, Lee

    2013-01-01

    Building a stronger teacher workforce requires the thoughtful orchestration of multiple processes working together in a human capital system. This white paper presents a framework that can be used to take stock of current efforts to enhance the teacher workforce in school districts or educational organizations, as well as their underlying theories…

  11. Performance evaluation of a kinesthetic-tactual display

    Science.gov (United States)

    Jagacinski, R. J.; Flach, J. M.; Gilson, R. D.; Dunn, R. S.

    1982-01-01

    Simulator studies demonstrated the feasibility of using kinesthetic-tactual (KT) displays for providing collective and cyclic command information, and suggested that KT displays may increase pilot workload capability. A dual-axis laboratory tracking task suggested that beyond reduction in visual scanning, there may be additional sensory or cognitive benefits to the use of multiple sensory modalities. Single-axis laboratory tracking tasks revealed performance with a quickened KT display to be equivalent to performance with a quickened visual display for a low frequency sum-of-sinewaves input. In contrast, an unquickened KT display was inferior to an unquickened visual display. Full scale simulator studies and/or inflight testing are recommended to determine the generality of these results.

  12. Effect of display size on visual attention.

    Science.gov (United States)

    Chen, I-Ping; Liao, Chia-Ning; Yeh, Shih-Hao

    2011-06-01

    Attention plays an important role in the design of human-machine interfaces. However, current knowledge about attention is largely based on data obtained when using devices of moderate display size. With advancement in display technology comes the need for understanding attention behavior over a wider range of viewing sizes. The effect of display size on test participants' visual search performance was studied. The participants (N = 12) performed two types of visual search tasks, that is, parallel and serial search, under three display-size conditions (16 degrees, 32 degrees, and 60 degrees). Serial, but not parallel, search was affected by display size. In the serial task, mean reaction time for detecting a target increased with the display size.

  13. Spatial variation in pollinator-mediated selection on phenology, floral display and spur length in the orchid Gymnadenia conopsea.

    Science.gov (United States)

    Chapurlat, Elodie; Ågren, Jon; Sletvold, Nina

    2015-12-01

    Spatial variation in plant-pollinator interactions may cause variation in pollinator-mediated selection on floral traits, but to establish this link conclusively experimental studies are needed. We quantified pollinator-mediated selection on flowering phenology and morphology in four populations of the fragrant orchid Gymnadenia conopsea, and compared selection mediated by diurnal and nocturnal pollinators in two of the populations. Variation in pollinator-mediated selection explained most of the among-population variation in the strength of directional and correlational selection. Pollinators mediated correlational selection on pairs of display traits, and on one display trait and spur length, a trait affecting pollination efficiency. Only nocturnal pollinators selected for longer spurs, and mediated stronger selection on the number of flowers compared with diurnal pollinators in one population. The two types of pollinators caused correlational selection on different pairs of traits and selected for different combinations of spur length and number of flowers. The results demonstrate that spatial variation in interactions with pollinators may result in differences in directional and correlational selection on floral traits in a plant with a semi-generalized pollination system, and suggest that differences in the relative importance of diurnal and nocturnal pollinators can cause variation in selection. © 2015 The Authors. New Phytologist © 2015 New Phytologist Trust.

  14. Exploring interaction with 3D volumetric displays

    Science.gov (United States)

    Grossman, Tovi; Wigdor, Daniel; Balakrishnan, Ravin

    2005-03-01

    Volumetric displays generate true volumetric 3D images by actually illuminating points in 3D space. As a result, viewing their contents is similar to viewing physical objects in the real world. These displays provide a 360 degree field of view, and do not require the user to wear hardware such as shutter glasses or head-trackers. These properties make them a promising alternative to traditional display systems for viewing imagery in 3D. Because these displays have only recently been made available commercially (e.g., www.actuality-systems.com), their current use tends to be limited to non-interactive output-only display devices. To take full advantage of the unique features of these displays, however, it would be desirable if the 3D data being displayed could be directly interacted with and manipulated. We investigate interaction techniques for volumetric display interfaces, through the development of an interactive 3D geometric model building application. While this application area itself presents many interesting challenges, our focus is on the interaction techniques that are likely generalizable to interactive applications for other domains. We explore a very direct style of interaction where the user interacts with the virtual data using direct finger manipulations on and around the enclosure surrounding the displayed 3D volumetric image.

  15. A stronger patch test elicitation reaction to the allergen hydroxycitronellal plus the irritant sodium lauryl sulfate

    DEFF Research Database (Denmark)

    Heydorn, S; Andersen, K E; Johansen, J D

    2003-01-01

    Household and cleaning products often contain both allergens and irritants. The aim of this double-blinded, randomized, paired study was to determine whether patch testing with an allergen (hydroxycitronellal) combined with an irritant [sodium lauryl sulfate (SLS)] cause a stronger patch test...

  16. Fathers see stronger family resemblances than non-fathers in unrelated children's faces.

    Science.gov (United States)

    Bressan, Paola; Dal Pos, Stefania

    2012-12-01

    Even after they have taken all reasonable measures to decrease the probability that their spouses cheat on them, men still face paternal uncertainty. Such uncertainty can lead to paternal disinvestment, which reduces the children's probability to survive and reproduce, and thus the reproductive success of the fathers themselves. A theoretical model shows that, other things being equal, men who feel confident that they have fathered their spouses' offspring tend to enjoy greater fitness (i.e., leave a larger number of surviving progeny) than men who do not. This implies that fathers should benefit from exaggerating paternal resemblance. We argue that the self-deceiving component of this bias could be concealed by generalizing this resemblance estimation boost to (1) family pairs other than father-child and (2) strangers. Here, we tested the prediction that fathers may see, in unrelated children's faces, stronger family resemblances than non-fathers. In Study 1, 70 men and 70 women estimated facial resemblances between children paired, at three different ages (as infants, children, and adolescents), either to themselves or to their parents. In Study 2, 70 men and 70 women guessed the true parents of the same children among a set of adults. Men who were fathers reported stronger similarities between faces than non-fathers, mothers, and non-mothers did, but were no better at identifying childrens' real parents. We suggest that, in fathers, processing of facial resemblances is biased in a manner that reflects their (adaptive) wishful thinking that fathers and children are related.

  17. Reference-dependent Preferences and the Transmission of Monetary Policy

    DEFF Research Database (Denmark)

    Gaffeo, Edoardo; Petrella, Ivan; Pfajfar, Damjan

    depends on deviations of their consumption from a reference level below which aversion to loss is displayed. In line with the theory developed by Kahneman and Tversky (1979), losses in consumption utility loom larger than gains. This implies state-dependent degrees of real rigidity and elasticity...

  18. Volume scanning three-dimensional display with an inclined two-dimensional display and a mirror scanner

    Science.gov (United States)

    Miyazaki, Daisuke; Kawanishi, Tsuyoshi; Nishimura, Yasuhiro; Matsushita, Kenji

    2001-11-01

    A new three-dimensional display system based on a volume-scanning method is demonstrated. To form a three-dimensional real image, an inclined two-dimensional image is rapidly moved with a mirror scanner while the cross-section patterns of a three-dimensional object are displayed sequentially. A vector-scan CRT display unit is used to obtain a high-resolution image. An optical scanning system is constructed with concave mirrors and a galvanometer mirror. It is confirmed that three-dimensional images, formed by the experimental system, satisfy all the criteria for human stereoscopic vision.

  19. Refreshing Refreshable Braille Displays.

    Science.gov (United States)

    Russomanno, Alexander; O'Modhrain, Sile; Gillespie, R Brent; Rodger, Matthew W M

    2015-01-01

    The increased access to books afforded to blind people via e-publishing has given them long-sought independence for both recreational and educational reading. In most cases, blind readers access materials using speech output. For some content such as highly technical texts, music, and graphics, speech is not an appropriate access modality as it does not promote deep understanding. Therefore blind braille readers often prefer electronic braille displays. But, these are prohibitively expensive. The search is on, therefore, for a low-cost refreshable display that would go beyond current technologies and deliver graphical content as well as text. And many solutions have been proposed, some of which reduce costs by restricting the number of characters that can be displayed, even down to a single braille cell. In this paper, we demonstrate that restricting tactile cues during braille reading leads to poorer performance in a letter recognition task. In particular, we show that lack of sliding contact between the fingertip and the braille reading surface results in more errors and that the number of errors increases as a function of presentation speed. These findings suggest that single cell displays which do not incorporate sliding contact are likely to be less effective for braille reading.

  20. Building Stronger State Energy Partnerships with the U.S. Department of Energy

    Energy Technology Data Exchange (ETDEWEB)

    Marks, Kate

    2011-09-30

    This final technical report details the results of total work efforts and progress made from October 2007 – September 2011 under the National Association of State Energy Officials (NASEO) cooperative agreement DE-FC26-07NT43264, Building Stronger State Energy Partnerships with the U.S. Department of Energy. Major topical project areas in this final report include work efforts in the following areas: Energy Assurance and Critical Infrastructure, State and Regional Technical Assistance, Regional Initiative, Regional Coordination and Technical Assistance, and International Activities in China. All required deliverables have been provided to the National Energy Technology Laboratory and DOE program officials.

  1. Gamma camera display system

    International Nuclear Information System (INIS)

    Stout, K.J.

    1976-01-01

    A gamma camera having an array of photomultipliers coupled via pulse shaping circuitry and a resistor weighting circuit to a display for forming an image of a radioactive subject is described. A linearizing circuit is coupled to the weighting circuit, the linearizing circuit including a nonlinear feedback circuit with diode coupling to the weighting circuit for linearizing the correspondence between points of the display and points of the subject. 4 Claims, 5 Drawing Figures

  2. Software for graphic display systems

    International Nuclear Information System (INIS)

    Karlov, A.A.

    1978-01-01

    In this paper some aspects of graphic display systems are discussed. The design of a display subroutine library is described, with an example, and graphic dialogue software is considered primarily from the point of view of the programmer who uses a high-level language. (Auth.)

  3. Remote handling recognition and display device

    International Nuclear Information System (INIS)

    Kimura, Motohiko.

    1979-01-01

    Purpose: To surely recognize the movements of remote handling equipments in a reactor by the use of a device in a simple structure. Constitution: A light emission surface and a light reception surface are provided, for example, putting therebetween a hook of a nob of a control rod as a remote control equipment. Depending on the position of the hook, there are two possible cases where the light can not arrive the light reception surface inhibited by the hook and where the light can be received not inhibited by the hook. By visually monitoring the presence or absence of the light reception from the outside of the reactor, the movement of the nob for the control rod can be recognized. Optical fibers connect the optical source with the light emission surface, and the light reception surface with the display surface. (Ikeda, J.)

  4. The relation of personality to alcohol abuse/dependence in a high-risk sample.

    Science.gov (United States)

    Loukas, A; Krull, J L; Chassin, L; Carle, A C

    2000-12-01

    The current study had two goals. The first goal was to test the mediational role of young adult personality in the relation between parental alcoholism and young adult alcoholism. The second was to examine the associations between personality and alcohol use motives and reasons to limit drinking in order to explore possible mechanisms by which personality may influence alcohol abuse/dependence. Multilevel modeling techniques were used to analyze data obtained from a community sample of young adult children of alcoholics and demographically matched controls. Results revealed that young adult neuroticism and agreeableness each, in part, mediated the effect of parental alcoholism on young adult alcoholism. Moreover, individuals high in neuloticism reported stronger coping motives to use alcohol, individuals low in agreeableness reported stronger coping motives and weaker upbringing reasons to limit drinking, and individuals low in conscientiousness reported stronger coping and enhancement motives to use alcohol, and weaker performance reasons to limit drinking.

  5. Information Display: Considerations for Designing Modern Computer-Based Display Systems

    International Nuclear Information System (INIS)

    O'Hara, J.; Pirus, D.; Beltracchi, L.

    2003-01-01

    OAK- B135 To help nuclear utilities and suppliers design and implement plant information management systems and displays that provide accurate and timely information and require minimal navigation and interface management

  6. Do External or Internal Technology Spillovers Have a Stronger Influence on Innovation Efficiency in China?

    Directory of Open Access Journals (Sweden)

    Xionghe Qin

    2017-09-01

    Full Text Available In this study, we bridge an important gap in the literature by comparing the extent to which external technology spillovers, as indicated by foreign direct investment (FDI, and internal technology spillovers, as indicated by university-institute-industry cooperation (UIC, influence innovation efficiency in China. We divide the innovation process into two sequential stages, namely the knowledge creation and technology commercialization stages, and employ a network data envelopment analysis approach to measure innovation efficiency at each stage. The spatial analysis of the distribution of knowledge creation efficiency and technology commercialization efficiency reveals the heterogeneity of innovation efficiency at the provincial level. Then, a panel data regression is used to analyze the effect of FDI and UIC on innovation efficiency at each stage, using data from 2009 to 2015 for 30 provinces in China. By comparing FDI with UIC, we find that FDI has a higher coefficient and stronger significance level at the knowledge creation stage, while only industry-institute linkages exhibit a stronger association with innovation efficiency at the technology commercialization stage.

  7. Operational status display and automation tools for FERMI-Elettra

    International Nuclear Information System (INIS)

    Scafuri, C.

    2012-01-01

    Detecting and locating faults and malfunctions of an accelerator is a difficult and time consuming task. The situation is even more difficult during the commissioning phase of a new accelerator, when the plants are not yet well known. Faults involving single devices are easy to detect, however a fault free machine does not imply that it is ready to run: the definition of malfunction depends on what is the expected behavior of the plant. In the case of FERMI-Elettra, in which the electron beam goes to different branches of the machine depending on the programmed activity, the configuration of the plant determines the rules for detecting malfunctions. In order to help the detection of faults and malfunctions and to display the status of the plant, a tool, known as the 'Matrix', has been developed. It is composed by a graphical front-end which displays a synthetic view of the plant status grouped by subsystem and location along the accelerator, and by a back-end calculation engine. The graphical front-end gives also the possibility, once a problem is detected, to focus on its details. The calculation engine is composed by a set of objects known as Sequencers. The calculation rules have been determined by analyzing the various subsystems and global working of the accelerator with plant and operations experts. The Sequencer is designed so that it can also issue commands to the plant. This will be used in the next releases of the Matrix for actively switching from one accelerator configuration to another. (author)

  8. Refreshable Braille displays using EAP actuators

    Science.gov (United States)

    Bar-Cohen, Yoseph

    2010-04-01

    Refreshable Braille can help visually impaired persons benefit from the growing advances in computer technology. The development of such displays in a full screen form is a great challenge due to the need to pack many actuators in small area without interferences. In recent years, various displays using actuators such as piezoelectric stacks have become available in commercial form but most of them are limited to one line Braille code. Researchers in the field of electroactive polymers (EAP) investigated methods of using these materials to form full screen displays. This manuscript reviews the state of the art of producing refreshable Braille displays using EAP-based actuators.

  9. Refreshable Braille Displays Using EAP Actuators

    Science.gov (United States)

    Bar-Cohen, Yoseph

    2010-01-01

    Refreshable Braille can help visually impaired persons benefit from the growing advances in computer technology. The development of such displays in a full screen form is a great challenge due to the need to pack many actuators in small area without interferences. In recent years, various displays using actuators such as piezoelectric stacks have become available in commercial form but most of them are limited to one line Braille code. Researchers in the field of electroactive polymers (EAP) investigated methods of using these materials to form full screen displays. This manuscript reviews the state of the art of producing refreshable Braille displays using EAP-based actuators..

  10. System Would Generate Virtual Heads-Up Display

    Science.gov (United States)

    Lambert, James L.

    1994-01-01

    Proposed helmet-mounted electronic display system superimposes full-color alphanumerical and/or graphical information onto observer's visual field. Displayed information projected directly onto observer's retinas, giving observer illusion of full-size computer display in foreground or background. Display stereoscopic, holographic, or in form of virtual image. Used by pilots to view navigational information while looking outside or at instruments, by security officers to view information about critical facilities while looking at visitors, or possibly even stock-exchange facilities to view desktop monitors and overhead displays simultaneously. System includes acousto-optical tunable filter (AOTF), which acts as both spectral filter and spatial light modulator.

  11. Manufacturing considerations for AMLCD cockpit displays

    Science.gov (United States)

    Luo, Fang-Chen

    1995-06-01

    AMLCD cockpit displays need to meet more stringent requirements compared with AMLCD commercial displays in areas such as environmental conditions, optical performance and device reliability. Special considerations are required for the manufacturing of AMLCD cockpit displays in each process step to address these issues. Some examples are: UV stable polarizers, wide-temperature LC material, strong LC glue seal, ESS test system, gray scale voltage EEPROM, etc.

  12. Context-dependent lexical ambiguity resolution: MEG evidence for the time-course of activity in left inferior frontal gyrus and posterior middle temporal gyrus.

    Science.gov (United States)

    Mollo, Giovanna; Jefferies, Elizabeth; Cornelissen, Piers; Gennari, Silvia P

    An MEG study investigated the role of context in semantic interpretation by examining the comprehension of ambiguous words in contexts leading to different interpretations. We compared high-ambiguity words in minimally different contexts (to bowl, the bowl) to low-ambiguity counterparts (the tray, to flog). Whole brain beamforming revealed the engagement of left inferior frontal gyrus (LIFG) and posterior middle temporal gyrus (LPMTG). Points of interest analyses showed that both these sites showed a stronger response to verb-contexts by 200 ms post-stimulus and displayed overlapping ambiguity effects that were sustained from 300 ms onwards. The effect of context was stronger for high-ambiguity words than for low-ambiguity words at several different time points, including within the first 100 ms post-stimulus. Unlike LIFG, LPMTG also showed stronger responses to verb than noun contexts in low-ambiguity trials. We argue that different functional roles previously attributed to LIFG and LPMTG are in fact played out at different periods during processing. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  13. Peptide-MHC class I stability is a stronger predictor of CTL immunogenicity than peptide affinity

    DEFF Research Database (Denmark)

    Harndahl, Mikkel Nors; Rasmussen, Michael; Nielsen, Morten

    2012-01-01

    Peptide-MHC class I stability is a stronger predictor of CTL immunogenicity than peptide affinity Mikkel Harndahla, Michael Rasmussena, Morten Nielsenb, Soren Buusa,∗ a Laboratory of Experimental Immunology, Faculty of Health Sciences, University of Copenhagen, Denmark b Center for Biological Seq...... al., 2007. J. Immunol. 178, 7890–7901. doi:10.1016/j.molimm.2012.02.025...

  14. Designing low cost LED display for the billboard

    Science.gov (United States)

    Hong, Yi-Jian; Uang, Chii-Maw; Wang, Ping-Chieh; Ho, Zu-Sheng

    2011-10-01

    With quickly advance of the computer, microelectronics and photonics technologies, LED display panel becomes a new electronic advertising media. It can be used to show any information whatever characters or graphics. Most LED display panels are built of many Light-Emitting Diodes arranged in a matrix form. The display has many advantages such as low power, low cost, long life and high definition. Because the display panel is asked to show rich color, the LED display panel's driving system becomes very complex. The design methodology of LED display panel's driver becomes more and more important to meet the market requirements. Cost is always the most important issue in public market domain. In this paper, we report a design methodology of LED display panel's driver based on the microprocessor control unit (MCU) system and LED display controller IC, HT1632C, to control three colors, RGB, color LED display panel and the modular panel size is 24*16 in matrix form. The HT1632C is a memory mapping LED display controller, it can be used on many applications, such as digital clock, thermometer, counter, voltmeter or other instrumentation readouts. Three pieces of HT1632C are used to drive a 24*16 RGB LED display panel, in our design case. Each HT163C chip is used to control one of the R, G and B color. As the drive mode is driven in DC mode, the RGB display panel can create and totally of seven colors under the control of MCU. The MCU generates the control signal to drive HT1632C. In this study, the software design methodology is adopted with dynamic display principle. When the scan frequency is 60Hz, LED display panel will get the clear picture and be able to display seven colors.

  15. Enforcement costs: some humanitarian alternatives to stronger patent rights.

    Science.gov (United States)

    Trotter, Andrew

    2012-01-01

    Diseases that cause comparatively few problems in developed countries kill millions of people in the Third World each year. In many cases, people die because they cannot afford the medication needed to save their lives. In others, there are simply no drugs available because there are no wealthy western patients to justify pharmaceutical companies investing in a cure. This reveals a deep-seated problem within the patent system and the pharmaceutical industry that emphasises markets and profits at the expense of health and global welfare. Global efforts have seen substantial improvements in access to medicines in isolated areas, but with international agreements driving towards stronger patent protection and the expiry date for the TRIPS grace period fast approaching, it is time to consider alternatives which will allow the patent system to work for the humanitarian cause rather than against it. This paper considers two such problems in the patent system and pharmaceutical industry - prohibitive pricing and misdirected incentives - to offer a mode of regulation and enforcement that will support both a viable pharmaceutical industry and the human right to health and medication.

  16. [Application of the grayscale standard display function to general purpose liquid-crystal display monitors for clinical use].

    Science.gov (United States)

    Tanaka, Nobukazu; Naka, Kentaro; Sueoka, Masaki; Higashida, Yoshiharu; Morishita, Junji

    2010-01-20

    Interpretations of medical images have been shifting to soft-copy readings with liquid-crystal display (LCD) monitors. The display function of the medical-grade LCD monitor for soft-copy readings is recommended to calibrate the grayscale standard display function (GSDF) in accordance with the guidelines of Japan and other countries. In this study, the luminance and display function of five models of eight general purpose LCD monitors were measured to gain an understanding of their characteristics. Moreover, the display function (gamma 2.2 or gamma 1.8) of general purpose LCD monitors was converted to GSDF through the use of a look-up table, and the detectability of a simulated lung nodule in the chest x-ray image was examined. As a result, the maximum luminance, contrast ratio, and luminance uniformity of general purpose LCD monitors, except for one model of two LCD monitors, met the management grade 1 standard in the guideline JESRA X-0093-2005. In addition, the detectability of simulated lung nodule in the mediastinal space was obviously improved by converting the display function of a general purpose LCD monitor into GSDF.

  17. Generating Animated Displays of Spacecraft Orbits

    Science.gov (United States)

    Candey, Robert M.; Chimiak, Reine A.; Harris, Bernard T.

    2005-01-01

    Tool for Interactive Plotting, Sonification, and 3D Orbit Display (TIPSOD) is a computer program for generating interactive, animated, four-dimensional (space and time) displays of spacecraft orbits. TIPSOD utilizes the programming interface of the Satellite Situation Center Web (SSCWeb) services to communicate with the SSC logic and database by use of the open protocols of the Internet. TIPSOD is implemented in Java 3D and effects an extension of the preexisting SSCWeb two-dimensional static graphical displays of orbits. Orbits can be displayed in any or all of the following seven reference systems: true-of-date (an inertial system), J2000 (another inertial system), geographic, geomagnetic, geocentric solar ecliptic, geocentric solar magnetospheric, and solar magnetic. In addition to orbits, TIPSOD computes and displays Sibeck's magnetopause and Fairfield's bow-shock surfaces. TIPSOD can be used by the scientific community as a means of projection or interpretation. It also has potential as an educational tool.

  18. Spin-dependent optics with metasurfaces

    Directory of Open Access Journals (Sweden)

    Xiao Shiyi

    2016-11-01

    Full Text Available Optical spin-Hall effect (OSHE is a spin-dependent transportation phenomenon of light as an analogy to its counterpart in condensed matter physics. Although being predicted and observed for decades, this effect has recently attracted enormous interests due to the development of metamaterials and metasurfaces, which can provide us tailor-made control of the light-matter interaction and spin-orbit interaction. In parallel to the developments of OSHE, metasurface gives us opportunities to manipulate OSHE in achieving a stronger response, a higher efficiency, a higher resolution, or more degrees of freedom in controlling the wave front. Here, we give an overview of the OSHE based on metasurface-enabled geometric phases in different kinds of configurational spaces and their applications on spin-dependent beam steering, focusing, holograms, structured light generation, and detection. These developments mark the beginning of a new era of spin-enabled optics for future optical components.

  19. Oil defect detection of electrowetting display

    Science.gov (United States)

    Chiang, Hou-Chi; Tsai, Yu-Hsiang; Yan, Yung-Jhe; Huang, Ting-Wei; Mang, Ou-Yang

    2015-08-01

    In recent years, transparent display is an emerging topic in display technologies. Apply in many fields just like mobile device, shopping or advertising window, and etc. Electrowetting Display (EWD) is one kind of potential transparent display technology advantages of high transmittance, fast response time, high contrast and rich color with pigment based oil system. In mass production process of Electrowetting Display, oil defects should be found by Automated Optical Inspection (AOI) detection system. It is useful in determination of panel defects for quality control. According to the research of our group, we proposed a mechanism of AOI detection system detecting the different kinds of oil defects. This mechanism can detect different kinds of oil defect caused by oil overflow or material deteriorated after oil coating or driving. We had experiment our mechanism with a 6-inch Electrowetting Display panel from ITRI, using an Epson V750 scanner with 1200 dpi resolution. Two AOI algorithms were developed, which were high speed method and high precision method. In high precision method, oil jumping or non-recovered can be detected successfully. This mechanism of AOI detection system can be used to evaluate the oil uniformity in EWD panel process. In the future, our AOI detection system can be used in quality control of panel manufacturing for mass production.

  20. Becoming Stronger at Broken Places: A Model for Group Work with Young Adult from Divorced Families.

    Science.gov (United States)

    Hage, Sally M.; Nosanow, Mia

    2000-01-01

    Describes a model for group work with young adults from divorced families using an 8-session psychoeducational group intervention. Goals include reducing isolation, establishing connectedness, and building a stronger sense of identify. By educating young adults on topics such as assertiveness, communication skills, and self-esteem, it will give…

  1. You Be the Judge: Display.

    Science.gov (United States)

    Koeninger, Jimmy G.

    The instructional package was developed to provide the distributive education teacher-coordinator with visual materials that can be used to supplement existing textbook offerings in the area of display (visual merchandising). Designed for use with 35mm slides of retail store displays, the package allows the student to view the slides of displays…

  2. Psychophysical analysis of monitor display functions affecting observer diagnostic performance of CT image on liquid crystal display monitors

    International Nuclear Information System (INIS)

    Yamaguchi, M.; Fujita, H.; Asai, Y.; Uemura, M.; Ookura, Y.; Matsumoto, M.; Johkoh, T.

    2005-01-01

    The aim of the present study was to propose suitable display functions for CT image representation on liquid crystal display (LCD) monitors by analyzing the characteristics of the monitor's typical display functions using psychophysical analysis. The luminance of the LCD monitor was adjusted to a maximum of 275 cd/m 2 and 480 cd/m 2 . Three types of postcalibrated display functions (i.e., GSDF, CIELAB, and Exponential γ 2.2) were evaluated. Luminance calculation of a new grayscale test pattern (NGTP) was done for the conversion of the digital driving level (DDL) into the CT value. The psychophysical gradient δ of display functions for the CT value was evaluated and compared via statistical analysis. The δ value of GSDF and CIE decreased exponentially; however, the δ value of Exponential γ 2.2 showed a convex curve with a peak at a specific point. There was a statistically significant difference among the δ values of the three types of display functions on the 480 cd/m 2 maximum via Kruskal Wallis test (P<0.001). The GSDF was suitable for observation of abdominal and lung CT images; however, the display function combined the Exponential γ 2.2 and the GSDF functions and was ideal for observation of brain CT images by psychophysical analysis. (orig.)

  3. Method for control-room display design

    International Nuclear Information System (INIS)

    Montmayeul, R.

    1988-01-01

    This document describes a method for control-room displays design. It can be used either for isolated display to add to an existing system either for the design of a full system of operator aids. The method is a top-down design with steps of possible iteration. The emphasis is put on display design rather than on system design; system aspects are just mentioned. Advantages of using a method are described [fr

  4. Statistical Arbitrage Mining for Display Advertising

    OpenAIRE

    Zhang, Weinan; Wang, Jun

    2015-01-01

    We study and formulate arbitrage in display advertising. Real-Time Bidding (RTB) mimics stock spot exchanges and utilises computers to algorithmically buy display ads per impression via a real-time auction. Despite the new automation, the ad markets are still informationally inefficient due to the heavily fragmented marketplaces. Two display impressions with similar or identical effectiveness (e.g., measured by conversion or click-through rates for a targeted audience) may sell for quite diff...

  5. Frequency of Gingival Display During Smiling and Comparison of Biometric Measurements in Subjects with and without Gingival Display

    International Nuclear Information System (INIS)

    Khan, F.; Abbas, M.

    2014-01-01

    Objective: To determine the frequency of gingival display during smiling and to compare biometric measurements in subjects with and without gingival display. Study Design: Cross-sectional study. Place and Duration of Study: Department of Prosthodontics, Dr. Ishrat-ul-Ibad Khan Institute of Oral Health Sciences, Dow University of Health Sciences, Karachi, from October 2012 to March 2013. Methodology: A total of 275 subjects (121 men and 154 women) were included in this study. The age of the participants ranged between 21 and 65 years. Measurements were carried out using digital caliper. For each participants, the gingival display was judged as either visible or not. The amounts of horizontal and vertical overlap of anterior teeth were measured using a digital caliper. Gender differences in these parameters and the relationship between subjects showing gingival display when smiling and the two intraoral dental biometric measurements were determined. Statistical analyses of data were performed using SPSS version 17.0 software. The mean scores for gender were calculated and a Student's t-test was used to identify significant differences between both groups. Significant level was set to 0.05. Results: A relatively small percentage of the subjects (37.8%) displayed gingiva when smiling. More women significantly displayed gingiva when smiling than men, with a 2:1 female: male ratio. Women had significantly (p=0.001) more horizontal overlap (3.34 +- 1.45 mm) than men (2.90 +- 1.44 mm), although no significant gender difference were found in vertical overlap. Subjects with gingival display had significantly (p < 0.05) more horizontal (3.49 +- 1.36 mm) and vertical (3.26 +- 1.47 mm) overlap of anterior teeth compared to those who did not display gingiva when smiling. Conclusion: Significantly more women displayed gingiva in smiling. Women had significantly more horizontal overlap than men. No gender differences were recorded between vertical overlap. Subjects who displayed

  6. Three-dimensional volumetric display by inclined-plane scanning

    Science.gov (United States)

    Miyazaki, Daisuke; Eto, Takuma; Nishimura, Yasuhiro; Matsushita, Kenji

    2003-05-01

    A volumetric display system based on three-dimensional (3-D) scanning that uses an inclined two-dimensional (2-D) image is described. In the volumetric display system a 2-D display unit is placed obliquely in an imaging system into which a rotating mirror is inserted. When the mirror is rotated, the inclined 2-D image is moved laterally. A locus of the moving image can be observed by persistence of vision as a result of the high-speed rotation of the mirror. Inclined cross-sectional images of an object are displayed on the display unit in accordance with the position of the image plane to observe a 3-D image of the object by persistence of vision. Three-dimensional images formed by this display system satisfy all the criteria for stereoscopic vision. We constructed the volumetric display systems using a galvanometer mirror and a vector-scan display unit. In addition, we constructed a real-time 3-D measurement system based on a light section method. Measured 3-D images can be reconstructed in the 3-D display system in real time.

  7. Displays: Entering a New Dimension

    Science.gov (United States)

    Starkman, Neal

    2007-01-01

    As display technologies prepare to welcome 3-D, the 21st-century classroom will soon bear little resemblance to anything students and teachers have ever seen. In this article, the author presents the latest innovations in the world of digital display technology. These include: (1) Touchlight, an interactive touch screen program that takes a normal…

  8. Crystal ball single event display

    International Nuclear Information System (INIS)

    Grosnick, D.; Gibson, A.; Allgower, C.; Alyea, J.; Argonne National Lab., IL

    1997-01-01

    The Single Event Display (SED) is a routine that is designed to provide information graphically about a triggered event within the Crystal Ball. The SED is written entirely in FORTRAN and uses the CERN-based HICZ graphing package. The primary display shows the amount of energy deposited in each of the NaI crystals on a Mercator-like projection of the crystals. Ten different shades and colors correspond to varying amounts of energy deposited within a crystal. Information about energy clusters is displayed on the crystal map by outlining in red the thirteen (or twelve) crystals contained within a cluster and assigning each cluster a number. Additional information about energy clusters is provided in a series of boxes containing useful data about the energy distribution among the crystals within the cluster. Other information shown on the event display include the event trigger type and data about π o 's and η's formed from pairs of clusters as found by the analyzer. A description of the major features is given, along with some information on how to install the SED into the analyzer

  9. Synthetic vision display evaluation studies

    Science.gov (United States)

    Regal, David M.; Whittington, David H.

    1994-01-01

    The goal of this research was to help us understand the display requirements for a synthetic vision system for the High Speed Civil Transport (HSCT). Four experiments were conducted to examine the effects of different levels of perceptual cue complexity in displays used by pilots in a flare and landing task. Increased levels of texture mapping of terrain and runway produced mixed results, including harder but shorter landings and a lower flare initiation altitude. Under higher workload conditions, increased texture resulted in an improvement in performance. An increase in familiar size cues did not result in improved performance. Only a small difference was found between displays using two patterns of high resolution texture mapping. The effects of increased perceptual cue complexity on performance was not as strong as would be predicted from the pilot's subjective reports or from related literature. A description of the role of a synthetic vision system in the High Speed Civil Transport is provide along with a literature review covering applied research related to perceptual cue usage in aircraft displays.

  10. Angular dependence of spin-orbit spin-transfer torques

    KAUST Repository

    Lee, Ki-Seung

    2015-04-06

    In ferromagnet/heavy-metal bilayers, an in-plane current gives rise to spin-orbit spin-transfer torque, which is usually decomposed into fieldlike and dampinglike torques. For two-dimensional free-electron and tight-binding models with Rashba spin-orbit coupling, the fieldlike torque acquires nontrivial dependence on the magnetization direction when the Rashba spin-orbit coupling becomes comparable to the exchange interaction. This nontrivial angular dependence of the fieldlike torque is related to the Fermi surface distortion, determined by the ratio of the Rashba spin-orbit coupling to the exchange interaction. On the other hand, the dampinglike torque acquires nontrivial angular dependence when the Rashba spin-orbit coupling is comparable to or stronger than the exchange interaction. It is related to the combined effects of the Fermi surface distortion and the Fermi sea contribution. The angular dependence is consistent with experimental observations and can be important to understand magnetization dynamics induced by spin-orbit spin-transfer torques.

  11. Angular dependence of spin-orbit spin-transfer torques

    KAUST Repository

    Lee, Ki-Seung; Go, Dongwook; Manchon, Aurelien; Haney, Paul M.; Stiles, M. D.; Lee, Hyun-Woo; Lee, Kyung-Jin

    2015-01-01

    In ferromagnet/heavy-metal bilayers, an in-plane current gives rise to spin-orbit spin-transfer torque, which is usually decomposed into fieldlike and dampinglike torques. For two-dimensional free-electron and tight-binding models with Rashba spin-orbit coupling, the fieldlike torque acquires nontrivial dependence on the magnetization direction when the Rashba spin-orbit coupling becomes comparable to the exchange interaction. This nontrivial angular dependence of the fieldlike torque is related to the Fermi surface distortion, determined by the ratio of the Rashba spin-orbit coupling to the exchange interaction. On the other hand, the dampinglike torque acquires nontrivial angular dependence when the Rashba spin-orbit coupling is comparable to or stronger than the exchange interaction. It is related to the combined effects of the Fermi surface distortion and the Fermi sea contribution. The angular dependence is consistent with experimental observations and can be important to understand magnetization dynamics induced by spin-orbit spin-transfer torques.

  12. Gliding lizards use the position of the sun to enhance social display.

    Science.gov (United States)

    Klomp, Danielle A; Stuart-Fox, Devi; Das, Indraneil; Ord, Terry J

    2017-02-01

    Effective communication requires animal signals to be readily detected by receivers in the environments in which they are typically given. Certain light conditions enhance the visibility of colour signals and these conditions can vary depending on the orientation of the sun and the position of the signaller. We tested whether Draco sumatranus gliding lizards modified their position relative to the sun to enhance the conspicuousness of their throat-fan (dewlap) during social display to conspecifics. The dewlap was translucent, and we found that lizards were significantly more likely to orient themselves perpendicular to the sun when displaying. This increases the dewlap's radiance, and likely, its conspicuousness, by increasing the amount of light transmitted through the ornament. This is a rare example of a behavioural adaptation for enhancing the visibility of an ornament to distant receivers. © 2017 The Author(s).

  13. Touch sensitive electrorheological fluid based tactile display

    Science.gov (United States)

    Liu, Yanju; Davidson, Rob; Taylor, Paul

    2005-12-01

    A tactile display is programmable device whose controlled surface is intended to be investigated by human touch. It has a great number of potential applications in the field of virtual reality and elsewhere. In this research, a 5 × 5 tactile display array including electrorheological (ER) fluid has been developed and investigated. Force responses of the tactile display array have been measured while a probe was moved across the upper surface. The purpose of this was to simulate the action of touch performed by human finger. Experimental results show that the sensed surface information could be controlled effectively by adjusting the voltage activation pattern imposed on the tactels. The performance of the tactile display is durable and repeatable. The touch sensitivity of this ER fluid based tactile display array has also been investigated in this research. The results show that it is possible to sense the touching force normal to the display's surface by monitoring the change of current passing through the ER fluid. These encouraging results are helpful for constructing a new type of tactile display based on ER fluid which can act as both sensor and actuator at the same time.

  14. Volumetric, dashboard-mounted augmented display

    Science.gov (United States)

    Kessler, David; Grabowski, Christopher

    2017-11-01

    The optical design of a compact volumetric display for drivers is presented. The system displays a true volume image with realistic physical depth cues, such as focal accommodation, parallax and convergence. A large eyebox is achieved with a pupil expander. The windshield is used as the augmented reality combiner. A freeform windshield corrector is placed at the dashboard.

  15. Flexible Bistable Cholesteric Reflective Displays

    Science.gov (United States)

    Yang, Deng-Ke

    2006-03-01

    Cholesteric liquid crystals (ChLCs) exhibit two stable states at zero field condition-the reflecting planar state and the nonreflecting focal conic state. ChLCs are an excellent candidate for inexpensive and rugged electronic books and papers. This paper will review the display cell structure,materials and drive schemes for flexible bistable cholesteric (Ch) reflective displays.

  16. Head-worn display-based augmented reality system for manufacturing

    Science.gov (United States)

    Sarwal, Alok; Baker, Chris; Filipovic, Dragan

    2005-05-01

    This system provides real-time guidance for training and problem-solving on production-line machinery. A prototype of a wearable, real-time, video guidance, interactive system for use in manufacturing, has been developed and demonstrated. Anticipated benefits are: relatively inexperienced personnel can provide machine servicing and the dependency on the vendor to repair or maintain equipment is significantly reduced. Additionally, servicing, training or part change-over schedules can be exercised more predictably and with less training. This approach utilizes Head Worn Display or Head Mounted Display (HMD) technology that can be readily adapted for various machines on the factory floor with training steps for a new location. Such a system can support various applications in manufacturing such as direct video guiding or applying scheduled maintenance and training to effectively resolve servicing emergencies and reduce machine downtime. It can also provide training of inexperienced operators and maintenance personnel. The gap between production line complexity and ability of production personnel to effectively maintain equipment is expected to widen in the future and advanced equipment will require complex servicing procedures that are neither well documented nor user-friendly. This system offers benefits in increased manufacturing equipment availability by facilitating effective servicing and training and can interface to a server system for additional computational resources on an as-needed basis. This system utilizes markers to guide the user and enforces a well defined sequence of operations. It performs augmentation of information on the display in order to provide guidance in real-time.

  17. Multimethods approach to safety-parameter-display evaluation

    International Nuclear Information System (INIS)

    Banks, W.W.; Blackman, H.S.; Gertman, D.I.; Petersen, R.J.

    1982-01-01

    The Human Factors Engineering Office of EG and G Idaho performed this NRC-funded study to assist the NRC in objectively assessing licensee-developed safety parameter display (SPD) formats and designs. The purpose of this study was to quantitatively measure the degree to which a tachistoscopic method of display evaluation would correlate with the results of a multidimensional rating approach to display evaluation. Results of the following three experiments will be presented; (a) tachistoscopic, (b) multidimensional rating scale, and (c) the combined results of a and b. The test material for all experiments consisted of three multivariate data display formats all under development as SPDs for reactor control rooms presenting safety parameter display data at the loss-of-fluid test (LOFT) facility. The three display formats studied were stars, deviation bar graphs, and meters. Eighteen adult volunteers were used as subjects. All were currently qualified reactor operators from the LOFT reactor plant, with a mean of 9.4 years reactor operating experience

  18. Antecedents and consequences of emotional display rule perceptions.

    Science.gov (United States)

    Diefendorff, James M; Richard, Erin M

    2003-04-01

    Central to all theories of emotional labor is the idea that individuals follow emotional display rules that specify the appropriate expression of emotions on the job. This investigation examined antecedents and consequences of emotional display rule perceptions. Full-time working adults (N = 152) from a variety of occupations provided self-report data, and supervisors and coworkers completed measures pertaining to the focal employees. Results using structural equation modeling revealed that job-based interpersonal requirements, supervisor display rule perceptions, and employee extraversion and neuroticism were predictive of employee display rule perceptions. Employee display rule perceptions, in turn, were related to self-reported job satisfaction and coworker ratings of employees' emotional displays on the job. Finally, neuroticism had direct negative relationships with job satisfaction and coworker ratings of employees' emotional displays.

  19. New portable FELIX 3D display

    Science.gov (United States)

    Langhans, Knut; Bezecny, Daniel; Homann, Dennis; Bahr, Detlef; Vogt, Carsten; Blohm, Christian; Scharschmidt, Karl-Heinz

    1998-04-01

    An improved generation of our 'FELIX 3D Display' is presented. This system is compact, light, modular and easy to transport. The created volumetric images consist of many voxels, which are generated in a half-sphere display volume. In that way a spatial object can be displayed occupying a physical space with height, width and depth. The new FELIX generation uses a screen rotating with 20 revolutions per second. This target screen is mounted by an easy to change mechanism making it possible to use appropriate screens for the specific purpose of the display. An acousto-optic deflection unit with an integrated small diode pumped laser draws the images on the spinning screen. Images can consist of up to 10,000 voxels at a refresh rate of 20 Hz. Currently two different hardware systems are investigated. The first one is based on a standard PCMCIA digital/analog converter card as an interface and is controlled by a notebook. The developed software is provided with a graphical user interface enabling several animation features. The second, new prototype is designed to display images created by standard CAD applications. It includes the development of a new high speed hardware interface suitable for state-of-the- art fast and high resolution scanning devices, which require high data rates. A true 3D volume display as described will complement the broad range of 3D visualization tools, such as volume rendering packages, stereoscopic and virtual reality techniques, which have become widely available in recent years. Potential applications for the FELIX 3D display include imaging in the field so fair traffic control, medical imaging, computer aided design, science as well as entertainment.

  20. Digital Display Integration Project Project Online 2.0

    International Nuclear Information System (INIS)

    Bardsley, J. N.

    1999-01-01

    The electronic display industry is changing in three important ways. First, the dominance of the cathode ray tube (CRT) is being challenged by the development of flat panel displays (FPDs). This will lead to the availability of displays of higher performance, albeit at greater cost. Secondly, the analog interfaces between displays that show data and the computers that generate the data are being replaced by digital connections. Finally, a high-resolution display is becoming the most expensive component in computer system for homes and small offices. It is therefore desirable that the useful lifetime of the display extend over several years and that the electronics allows the display to be used with many different image sources. Hopefully, the necessity of having three or four large CRTs in one office to accommodate different computer operating systems or communication protocols will soon disappear. Instead, we hope to see a set of flat panels that can be switched to show several independent images from multiple sources or a composite image from a single source. The more rapid rate of technological improvements and the higher cost of flat panel displays raise the incentive for greater planning and guidance in the acquisition and integration of high performance displays into large organizations, such as LLNL. The goal of the Digital Display Integration Project (DDIP) is to provide such support. This will be achieved through collaboration with leading suppliers of displays, communications equipment and image-processing products, and by greater exchange of information within the Laboratory. The project will start in October 1999. During the first two years (FY2000-1), the primary focus of the program will be upon: introducing displays with high information content (over 5M pixels); facilitating the transition from analog to digital interfaces; enabling data transfer from key computer platforms; incorporating optical communications to remove length restrictions on data

  1. Evaluation of tactual displays for flight control

    Science.gov (United States)

    Levison, W. H.; Tanner, R. B.; Triggs, T. J.

    1973-01-01

    Manual tracking experiments were conducted to determine the suitability of tactual displays for presenting flight-control information in multitask situations. Although tracking error scores are considerably greater than scores obtained with a continuous visual display, preliminary results indicate that inter-task interference effects are substantially less with the tactual display in situations that impose high visual scanning workloads. The single-task performance degradation found with the tactual display appears to be a result of the coding scheme rather than the use of the tactual sensory mode per se. Analysis with the state-variable pilot/vehicle model shows that reliable predictions of tracking errors can be obtained for wide-band tracking systems once the pilot-related model parameters have been adjusted to reflect the pilot-display interaction.

  2. Real time speech formant analyzer and display

    Science.gov (United States)

    Holland, George E.; Struve, Walter S.; Homer, John F.

    1987-01-01

    A speech analyzer for interpretation of sound includes a sound input which converts the sound into a signal representing the sound. The signal is passed through a plurality of frequency pass filters to derive a plurality of frequency formants. These formants are converted to voltage signals by frequency-to-voltage converters and then are prepared for visual display in continuous real time. Parameters from the inputted sound are also derived and displayed. The display may then be interpreted by the user. The preferred embodiment includes a microprocessor which is interfaced with a television set for displaying of the sound formants. The microprocessor software enables the sound analyzer to present a variety of display modes for interpretive and therapeutic used by the user.

  3. Transparent 3D display for augmented reality

    Science.gov (United States)

    Lee, Byoungho; Hong, Jisoo

    2012-11-01

    Two types of transparent three-dimensional display systems applicable for the augmented reality are demonstrated. One of them is a head-mounted-display-type implementation which utilizes the principle of the system adopting the concave floating lens to the virtual mode integral imaging. Such configuration has an advantage in that the threedimensional image can be displayed at sufficiently far distance resolving the accommodation conflict with the real world scene. Incorporating the convex half mirror, which shows a partial transparency, instead of the concave floating lens, makes it possible to implement the transparent three-dimensional display system. The other type is the projection-type implementation, which is more appropriate for the general use than the head-mounted-display-type implementation. Its imaging principle is based on the well-known reflection-type integral imaging. We realize the feature of transparent display by imposing the partial transparency to the array of concave mirror which is used for the screen of reflection-type integral imaging. Two types of configurations, relying on incoherent and coherent light sources, are both possible. For the incoherent configuration, we introduce the concave half mirror array, whereas the coherent one adopts the holographic optical element which replicates the functionality of the lenslet array. Though the projection-type implementation is beneficial than the head-mounted-display in principle, the present status of the technical advance of the spatial light modulator still does not provide the satisfactory visual quality of the displayed three-dimensional image. Hence we expect that the head-mounted-display-type and projection-type implementations will come up in the market in sequence.

  4. New developments in flexible cholesteric liquid crystal displays

    Science.gov (United States)

    Schneider, Tod; Davis, Donald J.; Franklin, Sean; Venkataraman, Nithya; McDaniel, Diaz; Nicholson, Forrest; Montbach, Erica; Khan, Asad; Doane, J. William

    2007-02-01

    Flexible Cholesteric liquid crystal displays have been rapidly maturing into a strong contender in the flexible display market. Encapsulation of the Cholesteric liquid crystal permits the use of flexible plastic substrates and roll-to-roll production. Recent advances include ultra-thin displays, laser-cut segmented displays of variable geometry, and smart card applications. Exciting technologies such as simultaneous laser-edge sealing and singulation enable high volume production, excellent quality control and non-traditional display geometries and formats.

  5. 27 CFR 6.35 - Renting display space.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Renting display space. 6.35 Section 6.35 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU... Renting display space. The renting of display space by an industry member at a retail establishment...

  6. 27 CFR 6.56 - Renting display space.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Renting display space. 6.56 Section 6.56 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU... Distribution Service § 6.56 Renting display space. A promotion whereby an industry member rents display space...

  7. 14 CFR 255.4 - Display of information.

    Science.gov (United States)

    2010-01-01

    ... REGULATIONS AIRLINE COMPUTER RESERVATIONS SYSTEMS § 255.4 Display of information. (a) All systems shall provide at least one integrated display that includes the schedules, fares, rules, and availability of all... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Display of information. 255.4 Section 255.4...

  8. Volumetric 3D display with multi-layered active screens for enhanced the depth perception (Conference Presentation)

    Science.gov (United States)

    Kim, Hak-Rin; Park, Min-Kyu; Choi, Jun-Chan; Park, Ji-Sub; Min, Sung-Wook

    2016-09-01

    Three-dimensional (3D) display technology has been studied actively because it can offer more realistic images compared to the conventional 2D display. Various psychological factors such as accommodation, binocular parallax, convergence and motion parallax are used to recognize a 3D image. For glass-type 3D displays, they use only the binocular disparity in 3D depth cues. However, this method cause visual fatigue and headaches due to accommodation conflict and distorted depth perception. Thus, the hologram and volumetric display are expected to be an ideal 3D display. Holographic displays can represent realistic images satisfying the entire factors of depth perception. But, it require tremendous amount of data and fast signal processing. The volumetric 3D displays can represent images using voxel which is a physical volume. However, it is required for large data to represent the depth information on voxel. In order to simply encode 3D information, the compact type of depth fused 3D (DFD) display, which can create polarization distributed depth map (PDDM) image having both 2D color image and depth image is introduced. In this paper, a new volumetric 3D display system is shown by using PDDM image controlled by polarization controller. In order to introduce PDDM image, polarization states of the light through spatial light modulator (SLM) was analyzed by Stokes parameter depending on the gray level. Based on the analysis, polarization controller is properly designed to convert PDDM image into sectioned depth images. After synchronizing PDDM images with active screens, we can realize reconstructed 3D image. Acknowledgment This work was supported by `The Cross-Ministry Giga KOREA Project' grant from the Ministry of Science, ICT and Future Planning, Korea

  9. Enhanced Adsorption and Recovery of Uranyl Ions by NikR Mutant-Displaying Yeast

    Directory of Open Access Journals (Sweden)

    Kouichi Kuroda

    2014-04-01

    Full Text Available Uranium is one of the most important metal resources, and the technology for the recovery of uranyl ions (UO22+ from aqueous solutions is required to ensure a semi-permanent supply of uranium. The NikR protein is a Ni2+-dependent transcriptional repressor of the nickel-ion uptake system in Escherichia coli, but its mutant protein (NikRm is able to selectively bind uranyl ions in the interface of the two monomers. In this study, NikRm protein with ability to adsorb uranyl ions was displayed on the cell surface of Saccharomyces cerevisiae. To perform the binding of metal ions in the interface of the two monomers, two metal-binding domains (MBDs of NikRm were tandemly fused via linker peptides and displayed on the yeast cell surface by fusion with the cell wall-anchoring domain of yeast α-agglutinin. The NikRm-MBD-displaying yeast cells with particular linker lengths showed the enhanced adsorption of uranyl ions in comparison to the control strain. By treating cells with citrate buffer (pH 4.3, the uranyl ions adsorbed on the cell surface were recovered. Our results indicate that the adsorption system by yeast cells displaying tandemly fused MBDs of NikRm is effective for simple and concentrated recovery of uranyl ions, as well as adsorption of uranyl ions.

  10. Projection display industry market and technology trends

    Science.gov (United States)

    Castellano, Joseph A.; Mentley, David E.

    1995-04-01

    The projection display industry is diverse, embracing a variety of technologies and applications. In recent years, there has been a high level of interest in projection displays, particularly those using LCD panels or light valves because of the difficulty in making large screen, direct view displays. Many developers feel that projection displays will be the wave of the future for large screen HDTV (high-definition television), penetrating the huge existing market for direct view CRT-based televisions. Projection displays can have the images projected onto a screen either from the rear or the front; the main characteristic is their ability to be viewed by more than one person. In addition to large screen home television receivers, there are numerous other uses for projection displays including conference room presentations, video conferences, closed circuit programming, computer-aided design, and military command/control. For any given application, the user can usually choose from several alternative technologies. These include CRT front or rear projectors, LCD front or rear projectors, LCD overhead projector plate monitors, various liquid or solid-state light valve projectors, or laser-addressed systems. The overall worldwide market for projection information displays of all types and for all applications, including home television, will top DOL4.6 billion in 1995 and DOL6.45 billion in 2001.

  11. Brief history of electronic stereoscopic displays

    Science.gov (United States)

    Lipton, Lenny

    2012-02-01

    A brief history of recent developments in electronic stereoscopic displays is given concentrating on products that have succeeded in the market place and hence have had a significant influence on future implementations. The concentration is on plano-stereoscopic (two-view) technology because it is now the dominant display modality in the marketplace. Stereoscopic displays were created for the motion picture industry a century ago, and this technology influenced the development of products for science and industry, which in turn influenced product development for entertainment.

  12. Digest: Context matters: the effects of light environment and female presence on the structure of wolf spider courtship displays.

    Science.gov (United States)

    Fialko, Kristina

    2018-03-31

    Does variation in the environment in which a signal is presented affect the components of a complex, ritualized animal display? Using a signal phenotype network, Rosenthal et al. (2018) find that light and female presence alter the structure of wolf spider courtship displays, providing evidence that complex signaling behaviors may be modified depending on the social and environmental context. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  13. Advanced and tendencies in the development of display technologies

    Science.gov (United States)

    Kompanets, I. N.

    2006-06-01

    Advances and key display applications are discussed. Computer, compact mobile, TV and collective large screen displays are mentioned. Flat panel displays step on CRT devices to leave them behind in 2007. Materials, active matricies and applications of bright radiative field emission and organic LED displays are developing successively and pressing other technologies to be used in photo-cameras, cellular phones, auto-cars and avionics. Progress in flexible screens can substantially extend the display design and application soon. 3D display systems are under intensive development, and laser is an important unit in some vaiants of holographic and volumetric 3D displays. Value forecast of different display markets is presented.

  14. Color Analysis in Air Traffic Control Displays, Part II. Auxiliary Displays

    National Research Council Canada - National Science Library

    Xing, Jing

    2007-01-01

    ...), Traffic Management Advisor (TMA), and Integrated Terminal Weather System (ITWS). For each display, we documented the background and default colors, color-coding, color usage, associated purposes of color use, and color complexity...

  15. Visual Merchandising through Display: Advertising Services Occupations.

    Science.gov (United States)

    Maurer, Nelson S.

    The increasing use of displays by businessmen is creating a demand for display workers. This demand may be met by preparing high school students to enter the field of display. Additional workers might be recruited by offering adult training programs for individuals working within the stores. For this purpose a curriculum guide has been developed…

  16. 14 CFR 125.7 - Display of certificate.

    Science.gov (United States)

    2010-01-01

    ... OR MORE; AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT General § 125.7 Display of certificate. (a) The certificate holder must display a true copy of the certificate in each of its aircraft. (b... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Display of certificate. 125.7 Section 125.7...

  17. Screening for Internet dependence: do the proposed diagnostic criteria differentiate normal from dependent Internet use?

    Science.gov (United States)

    Dowling, Nicki A; Quirk, Kelly L

    2009-02-01

    There is continued discussion of including Internet dependence as a diagnosis in future editions of the Diagnostic and Statistical Manual of Mental Disorders. The primary aim of the study was to evaluate the utility of the proposed diagnostic criteria for Internet dependence as measured by Young's Diagnostic Questionnaire (YDQ). Although the YDQ does not provide any measure of severity, there is emerging recognition that some Internet users may display less severe or at risk Internet dependence. The degree to which the cutoff of 5 out of 8 criteria is appropriate to differentiate nondependent from dependent Internet use was evaluated by comparing the Internet usage and psychological dysfunction of 424 university students endorsing 3 and 4 diagnostic criteria (at-risk Internet dependence) to those endorsing less than 3 criteria (nondependent) and those endorsing 5 or more criteria (Internet dependence). The findings suggest that the proposed diagnostic criteria do not adequately discriminate individuals scoring 3 or 4 from those currently classified as Internet dependent. The implications of the findings for the assessment, diagnosis, and treatment of Internet dependence are discussed.

  18. Phosphorylation of purified mitochondrial Voltage-Dependent Anion Channel by c-Jun N-terminal Kinase-3 modifies channel voltage-dependence

    Directory of Open Access Journals (Sweden)

    Rajeev Gupta

    2017-06-01

    Full Text Available Voltage-Dependent Anion Channel (VDAC phosphorylated by c-Jun N-terminal Kinase-3 (JNK3 was incorporated into the bilayer lipid membrane. Single-channel electrophysiological properties of the native and the phosphorylated VDAC were compared. The open probability versus voltage curve of the native VDAC displayed symmetry around the voltage axis, whereas that of the phosphorylated VDAC showed asymmetry. This result indicates that phosphorylation by JNK3 modifies voltage-dependence of VDAC.

  19. Phosphorylation of purified mitochondrial Voltage-Dependent Anion Channel by c-Jun N-terminal Kinase-3 modifies channel voltage-dependence.

    Science.gov (United States)

    Gupta, Rajeev; Ghosh, Subhendu

    2017-06-01

    Voltage-Dependent Anion Channel (VDAC) phosphorylated by c-Jun N-terminal Kinase-3 (JNK3) was incorporated into the bilayer lipid membrane. Single-channel electrophysiological properties of the native and the phosphorylated VDAC were compared. The open probability versus voltage curve of the native VDAC displayed symmetry around the voltage axis, whereas that of the phosphorylated VDAC showed asymmetry. This result indicates that phosphorylation by JNK3 modifies voltage-dependence of VDAC.

  20. [Peptide phage display in biotechnology and biomedicine].

    Science.gov (United States)

    Kuzmicheva, G A; Belyavskaya, V A

    2016-07-01

    To date peptide phage display is one of the most common combinatorial methods used for identifying specific peptide ligands. Phage display peptide libraries containing billions different clones successfully used for selection of ligands with high affinity and selectivity toward wide range of targets including individual proteins, bacteria, viruses, spores, different kind of cancer cells and variety of nonorganic targets (metals, alloys, semiconductors etc.) Success of using filamentous phage in phage display technologies relays on the robustness of phage particles and a possibility to genetically modify its DNA to construct new phage variants with novel properties. In this review we are discussing characteristics of the most known non-commercial peptide phage display libraries of different formats (landscape libraries in particular) and their successful applications in several fields of biotechnology and biomedicine: discovery of peptides with diagnostic values against different pathogens, discovery and using of peptides recognizing cancer cells, trends in using of phage display technologies in human interactome studies, application of phage display technologies in construction of novel nano materials.

  1. Industrial Personal Computer based Display for Nuclear Safety System

    International Nuclear Information System (INIS)

    Kim, Ji Hyeon; Kim, Aram; Jo, Jung Hee; Kim, Ki Beom; Cheon, Sung Hyun; Cho, Joo Hyun; Sohn, Se Do; Baek, Seung Min

    2014-01-01

    The safety display of nuclear system has been classified as important to safety (SIL:Safety Integrity Level 3). These days the regulatory agencies are imposing more strict safety requirements for digital safety display system. To satisfy these requirements, it is necessary to develop a safety-critical (SIL 4) grade safety display system. This paper proposes industrial personal computer based safety display system with safety grade operating system and safety grade display methods. The description consists of three parts, the background, the safety requirements and the proposed safety display system design. The hardware platform is designed using commercially available off-the-shelf processor board with back plane bus. The operating system is customized for nuclear safety display application. The display unit is designed adopting two improvement features, i.e., one is to provide two separate processors for main computer and display device using serial communication, and the other is to use Digital Visual Interface between main computer and display device. In this case the main computer uses minimized graphic functions for safety display. The display design is at the conceptual phase, and there are several open areas to be concreted for a solid system. The main purpose of this paper is to describe and suggest a methodology to develop a safety-critical display system and the descriptions are focused on the safety requirement point of view

  2. Industrial Personal Computer based Display for Nuclear Safety System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hyeon; Kim, Aram; Jo, Jung Hee; Kim, Ki Beom; Cheon, Sung Hyun; Cho, Joo Hyun; Sohn, Se Do; Baek, Seung Min [KEPCO, Youngin (Korea, Republic of)

    2014-08-15

    The safety display of nuclear system has been classified as important to safety (SIL:Safety Integrity Level 3). These days the regulatory agencies are imposing more strict safety requirements for digital safety display system. To satisfy these requirements, it is necessary to develop a safety-critical (SIL 4) grade safety display system. This paper proposes industrial personal computer based safety display system with safety grade operating system and safety grade display methods. The description consists of three parts, the background, the safety requirements and the proposed safety display system design. The hardware platform is designed using commercially available off-the-shelf processor board with back plane bus. The operating system is customized for nuclear safety display application. The display unit is designed adopting two improvement features, i.e., one is to provide two separate processors for main computer and display device using serial communication, and the other is to use Digital Visual Interface between main computer and display device. In this case the main computer uses minimized graphic functions for safety display. The display design is at the conceptual phase, and there are several open areas to be concreted for a solid system. The main purpose of this paper is to describe and suggest a methodology to develop a safety-critical display system and the descriptions are focused on the safety requirement point of view.

  3. Viewpoint adaptive display of HDR images

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Mantel, Claire

    2017-01-01

    In this paper viewpoint adaptive display of HDR images incorporating the effects of ambient light is presented and evaluated. LED backlight displays may render HDR images, but while at a global scale a high dynamic range may be achieved, locally the contrast is limited by the leakage of light...... through the LC elements of the display. To render high quality images, the display with backlight dimming can compute the values of the LED backlight and LC elements based on the input image, information about the viewpoint of the observer(s) and information of the ambient light. The goal is to achieve...... the best perceptual reproduction of the specified target image derived from the HDR input image in the specific viewing situation including multiple viewers, possibly having different preferences. An optimization based approach is presented. Some tests with reproduced images are also evaluated subjectively...

  4. Display Sharing: An Alternative Paradigm

    Science.gov (United States)

    Brown, Michael A.

    2010-01-01

    The current Johnson Space Center (JSC) Mission Control Center (MCC) Video Transport System (VTS) provides flight controllers and management the ability to meld raw video from various sources with telemetry to improve situational awareness. However, maintaining a separate infrastructure for video delivery and integration of video content with data adds significant complexity and cost to the system. When considering alternative architectures for a VTS, the current system's ability to share specific computer displays in their entirety to other locations, such as large projector systems, flight control rooms, and back supporting rooms throughout the facilities and centers must be incorporated into any new architecture. Internet Protocol (IP)-based systems also support video delivery and integration. IP-based systems generally have an advantage in terms of cost and maintainability. Although IP-based systems are versatile, the task of sharing a computer display from one workstation to another can be time consuming for an end-user and inconvenient to administer at a system level. The objective of this paper is to present a prototype display sharing enterprise solution. Display sharing is a system which delivers image sharing across the LAN while simultaneously managing bandwidth, supporting encryption, enabling recovery and resynchronization following a loss of signal, and, minimizing latency. Additional critical elements will include image scaling support, multi -sharing, ease of initial integration and configuration, integration with desktop window managers, collaboration tools, host and recipient controls. This goal of this paper is to summarize the various elements of an IP-based display sharing system that can be used in today's control center environment.

  5. Development and validation of a measure of display rule knowledge: the display rule assessment inventory.

    Science.gov (United States)

    Matsumoto, David; Yoo, Seung Hee; Hirayama, Satoko; Petrova, Galina

    2005-03-01

    As one component of emotion regulation, display rules, which reflect the regulation of expressive behavior, have been the topic of many studies. Despite their theoretical and empirical importance, however, to date there is no measure of display rules that assesses a full range of behavioral responses that are theoretically possible when emotion is elicited. This article reports the development of a new measure of display rules that surveys 5 expressive modes: expression, deamplification, amplification, qualification, and masking. Two studies provide evidence for its internal and temporal reliability and for its content, convergent, discriminant, external, and concurrent predictive validity. Additionally, Study 1, involving American, Russian, and Japanese participants, demonstrated predictable cultural differences on each of the expressive modes. Copyright 2005 APA, all rights reserved.

  6. Why is the radial flow in central pA collisions stronger than in AA?

    International Nuclear Information System (INIS)

    Kalaydzhyan, Tigran; Shuryak, Edward

    2014-01-01

    Both the transverse size and entropy density per area in central pA collisions is smaller than in central AA, and yet the radial flow is stronger. We propose an explanation to this puzzle. Using a weak attraction between strings through the σ-meson exchange, fitted to the lattice data, we find collective implosion of the “spaghetti” multi-string state. Collectivization of the sigma field of the strings is the QCD analog of the black hole formation occurring in holographic models

  7. Display analysis with the optimal control model of the human operator. [pilot-vehicle display interface and information processing

    Science.gov (United States)

    Baron, S.; Levison, W. H.

    1977-01-01

    Application of the optimal control model of the human operator to problems in display analysis is discussed. Those aspects of the model pertaining to the operator-display interface and to operator information processing are reviewed and discussed. The techniques are then applied to the analysis of advanced display/control systems for a Terminal Configured Vehicle. Model results are compared with those obtained in a large, fixed-base simulation.

  8. Solar active region display system

    Science.gov (United States)

    Golightly, M.; Raben, V.; Weyland, M.

    2003-04-01

    The Solar Active Region Display System (SARDS) is a client-server application that automatically collects a wide range of solar data and displays it in a format easy for users to assimilate and interpret. Users can rapidly identify active regions of interest or concern from color-coded indicators that visually summarize each region's size, magnetic configuration, recent growth history, and recent flare and CME production. The active region information can be overlaid onto solar maps, multiple solar images, and solar difference images in orthographic, Mercator or cylindrical equidistant projections. Near real-time graphs display the GOES soft and hard x-ray flux, flare events, and daily F10.7 value as a function of time; color-coded indicators show current trends in soft x-ray flux, flare temperature, daily F10.7 flux, and x-ray flare occurrence. Through a separate window up to 4 real-time or static graphs can simultaneously display values of KP, AP, daily F10.7 flux, GOES soft and hard x-ray flux, GOES >10 and >100 MeV proton flux, and Thule neutron monitor count rate. Climatologic displays use color-valued cells to show F10.7 and AP values as a function of Carrington/Bartel's rotation sequences - this format allows users to detect recurrent patterns in solar and geomagnetic activity as well as variations in activity levels over multiple solar cycles. Users can customize many of the display and graph features; all displays can be printed or copied to the system's clipboard for "pasting" into other applications. The system obtains and stores space weather data and images from sources such as the NOAA Space Environment Center, NOAA National Geophysical Data Center, the joint ESA/NASA SOHO spacecraft, and the Kitt Peak National Solar Observatory, and can be extended to include other data series and image sources. Data and images retrieved from the system's database are converted to XML and transported from a central server using HTTP and SOAP protocols, allowing

  9. Digital image display system for emergency room

    International Nuclear Information System (INIS)

    Murry, R.C.; Lane, T.J.; Miax, L.S.

    1989-01-01

    This paper reports on a digital image display system for the emergency room (ER) in a major trauma hospital. Its objective is to reduce radiographic image delivery time to a busy ER while simultaneously providing a multimodality capability. Image storage, retrieval, and display will also be facilitated with this system. The system's backbone is a token-ring network of RISC and personal computers. The display terminals are higher- function RISC computers with 1,024 2 color or gray-scale monitors. The PCs serve as administrative terminals. Nuclear medicine, CT, MR, and digitized film images are transferred to the image display system

  10. Developing an integrated digitizing and display surface

    Science.gov (United States)

    Hipple, James D.; Wedding, Daniel K.; Wedding, Donald K., Sr.

    1995-04-01

    The development of an integrated digitizing and display surface, which utilizes touch entry and flat panel display (FPD) technology, is a significant hardware advance in the field of geographic information systems (GIS). Inherent qualities of the FPD, notably the ac gas plasma display, makes such a marriage inevitable. Large diagonal sizes, high resolution color, screen flatness, and monitor thickness are desirable features of an integrated digitizing and display surface. Recently, the GIS literature has addressed a need for such an innovation. The development of graphics displays based on sophisticated technologies include `photorealistic' (or high definition) imaging at resolutions of 2048 X 2048 or greater, palates of 16.7 million colors, formats greater than 30 inches diagonal, and integrated touch entry. In this paper, there is an evaluation of FPDs and data input technologies in the development of such a product.

  11. Helmet-mounted display requirements: just another head-up display (HUD) or a different animal altogether?

    Science.gov (United States)

    Newman, Richard L.; Haworth, Loran A.

    1994-06-01

    The helmet-mounted display (HMD) presents flight, navigation, and weapon information in the pilot's line of sight. The HMD was developed to allow the pilot to retain aircraft and weapon information while looking off boresight. The present study reviewed the state-of-the-art in HMDs and identified a number of issues applying to HMDs. Several are identical to head-up display (HUD) issues: symbol standardization, excessive clutter, and the need for integration with other cockpit displays and controls. Other issues are unique to the head-mounted display: symbol stabilization, inadequate definitions, undefined symbol drive laws, helmet considerations, and field-of-view (FOV) vs. resolution tradeoff requirements. Symbol stabilization is critical. In the Apache helicopter, the lack of compensation for pilot head motion creates excessive workload during hovering and nap-of-the-earth (NOE) flight. This high workload translates into excessive training requirements. At the same time, misleading symbology makes interpretation of the height of obstructions impossible. The underlying cause is the absence of design criteria for HMDs. The existing military standard does not reflect the current state of technology. In addition, there are inadequate test and evaluation guidelines. The situation parallels the situation for HUDs several years ago.

  12. Visual Stability of Objects and Environments Viewed through Head-Mounted Displays

    Science.gov (United States)

    Ellis, Stephen R.; Adelstein, Bernard D.

    2015-01-01

    Virtual Environments (aka Virtual Reality) is again catching the public imagination and a number of startups (e.g. Oculus) and even not-so-startup companies (e.g. Microsoft) are trying to develop display systems to capitalize on this renewed interest. All acknowledge that this time they will get it right by providing the required dynamic fidelity, visual quality, and interesting content for the concept of VR to take off and change the world in ways it failed to do so in past incarnations. Some of the surprisingly long historical background of the technology that the form of direct simulation that underlies virtual environment and augmented reality displays will be briefly reviewed. An example of a mid 1990's augmented reality display system with good dynamic performance from our lab will be used to illustrate some of the underlying phenomena and technology concerning visual stability of virtual environments and objects during movement. In conclusion some idealized performance characteristics for a reference system will be proposed. Interestingly, many systems more or less on the market now may actually meet many of these proposed technical requirements. This observation leads to the conclusion that the current success of the IT firms trying to commercialize the technology will depend on the hidden costs of using the systems as well as the development of interesting and compelling content.

  13. Digital Display Integration Project Project Online 2.0

    CERN Document Server

    Bardsley, J N

    1999-01-01

    The electronic display industry is changing in three important ways. First, the dominance of the cathode ray tube (CRT) is being challenged by the development of flat panel displays (FPDs). This will lead to the availability of displays of higher performance, albeit at greater cost. Secondly, the analog interfaces between displays that show data and the computers that generate the data are being replaced by digital connections. Finally, a high-resolution display is becoming the most expensive component in computer system for homes and small offices. It is therefore desirable that the useful lifetime of the display extend over several years and that the electronics allows the display to be used with many different image sources. Hopefully, the necessity of having three or four large CRTs in one office to accommodate different computer operating systems or communication protocols will soon disappear. Instead, we hope to see a set of flat panels that can be switched to show several independent images from multip...

  14. Autostereoscopic display technology for mobile 3DTV applications

    Science.gov (United States)

    Harrold, Jonathan; Woodgate, Graham J.

    2007-02-01

    Mobile TV is now a commercial reality, and an opportunity exists for the first mass market 3DTV products based on cell phone platforms with switchable 2D/3D autostereoscopic displays. Compared to conventional cell phones, TV phones need to operate for extended periods of time with the display running at full brightness, so the efficiency of the 3D optical system is key. The desire for increased viewing freedom to provide greater viewing comfort can be met by increasing the number of views presented. A four view lenticular display will have a brightness five times greater than the equivalent parallax barrier display. Therefore, lenticular displays are very strong candidates for cell phone 3DTV. Selection of Polarisation Activated Microlens TM architectures for LCD, OLED and reflective display applications is described. The technology delivers significant advantages especially for high pixel density panels and optimises device ruggedness while maintaining display brightness. A significant manufacturing breakthrough is described, enabling switchable microlenses to be fabricated using a simple coating process, which is also readily scalable to large TV panels. The 3D image performance of candidate 3DTV panels will also be compared using autostereoscopic display optical output simulations.

  15. Fabrication of WO3-based electrochromic displays using solid or gel-like organic electrolytes

    International Nuclear Information System (INIS)

    Vasilopoulou, M; Aspiotis, G; Kostis, I; Argitis, P; Davazoglou, D

    2005-01-01

    New all solid-state electrochromic displays were fabricated by chemically vapor depositing and patterning a tungsten oxide film on SnO 2 :F covered glass substrates. Aluminum sheets were used as counter electrodes to form electrochromic displays using solid or gel-like organic electrolytes. These ionically conductive and electronically insulating electrolytes were based on poly(methyl methacrylate) (PMMA) and poly(2-hydrohyethyl methacrylate) (PHEMA) into which phospho-tungstic acid was added at various concentrations. In some devices the electrolyte was formed by addition of photoacid generator into the polymeric matrix and exposure at deep UV light. It was found that displays exhibit an intense, reversible electrochromic effect with reflectivity varying by a factor of five between the uncolored to the colored state. The coloring voltage depends strongly on the polymeric matrix, the thickness of the electrolyte and post-apply baking conditions and is of the order of 6-9 V. The response time was found to be of the order of 500 ms; coloration and bleaching times were comparable

  16. Advanced image display systems in radiology

    International Nuclear Information System (INIS)

    Wendler, T.

    1987-01-01

    Advanced image display systems for the fully digital diagnostic imaging departments of the future will be far more than simple replacements of the traditional film-viewing equipment. The new capabilities of very high resolution and highly dynamic displays offer a userfriendly and problem-oriented way of image interpretation. Advanced harware-, software- and human-machine interaction-concepts have been outlined. A scenario for a future way of handling and displaying images, reflecting a new image viewing paradigm in radiology is sketched which has been realized in an experimental image workstation model in the laboratory which, despite its technical complexity, offers a consistent strategy for fast and convenient interaction with image objects. The perspective of knowledge based techniques for workstation control software with object-oriented programming environments and user- and task-adaptive behavior leads to more advanced display properties and a new quality of userfriendliness. 2 refs.; 5 figs

  17. Three-dimensional display improves observer speed and accuracy

    International Nuclear Information System (INIS)

    Nelson, J.A.; Rowberg, A.H.; Kuyper, S.; Choi, H.S.

    1989-01-01

    In an effort to evaluate the potential cost-effectiveness of three-dimensional (3D) display equipment, we compared the speed and accuracy of experienced radiologists identifying in sliced uppercase letters from CT scans with 2D and pseudo-3D display. CT scans of six capital letters were obtained and printed as a 2D display or as a synthesized pseudo-3D display (Pixar). Six observes performed a timed identification task. Radiologists read the 3D display an average of 16 times faster than the 2D, and the average error rate of 2/6 (± 0.6/6) for 2D interpretations was totally eliminated. This degree of improvement in speed and accuracy suggests that the expense of 3D display may be cost-effective in a defined clinical setting

  18. To 'display' or not to 'display'- that is the peptide

    CSIR Research Space (South Africa)

    Crampton, Michael C

    2008-11-01

    Full Text Available eukaryotic and prokaryotic systems but has mainly focused around phages (Etz et al, 2001), yeast (Kondo and Ueda, 2004) and bacteria (Lee et al 2003). The central variable domain of the FliC protein is dispensable and can be used for the insertion and display...

  19. Functional displays

    International Nuclear Information System (INIS)

    Angelis De, F.; Haentjens, J.

    1995-01-01

    The Functional Displays are directly derived from the Man-Machine Design key document: Function-Based Task Analysis. The presentation defines and describes the goals-means structure of the plant function along with applicable control volumes and parameters of interest. The purpose of the subject is to show, through an example of a preliminary design, what the main parts of a function are. (3 figs.)

  20. Display hardware

    International Nuclear Information System (INIS)

    Myers, D.R.

    1983-01-01

    To appreciate the limitations and possibilities of computer graphics it is necessary to have some acquaintance with the available technology. The aim of this chapter is to mention briefly the different display types and their 'ball-park' price ranges. It must be stressed that prices change rapidly, and so those quoted here are only intended to give an idea of the cost at the time of writing.

  1. A visual-display and storage device

    Science.gov (United States)

    Bosomworth, D. R.; Moles, W. H.

    1972-01-01

    Memory and display device uses cathodochromic material to store visual information and fast phosphor to recall information for display and electronic processing. Cathodochromic material changes color when bombarded with electrons, and is restored to its original color when exposed to light of appropiate wavelength.

  2. NCAP projection displays: key issues for commercialization

    Science.gov (United States)

    Tomita, Akira; Jones, Philip J.

    1992-06-01

    Recently there has been much interest in a new polymer nematic dispersion technology, often called as NCAP, PDLC, PNLC, LCPC, etc., since projection displays using this technology have been shown to produce much brighter display images than projectors using conventional twisted nematic (TN) lightvalves. For commercializing projection displays based on this polymer nematic dispersion technology, the new materials must not only meet various electro- optic requirements, e.g., operational voltage, `off-state'' scattering angle, voltage holding ratio and hysteresis, but must also be stable over the lifetime of the product. This paper reports recent progress in the development of NCAP based projection displays and discusses some of the key commercialization issues.

  3. Polyvalent Display of Biomolecules on Live Cells.

    Science.gov (United States)

    Shi, Peng; Zhao, Nan; Lai, Jinping; Coyne, James; Gaddes, Erin R; Wang, Yong

    2018-06-04

    Surface display of biomolecules on live cells offers new opportunities to treat human diseases and perform basic studies. Existing methods are primarily focused on monovalent functionalization, that is, the display of single biomolecules across the cell surface. Here we show that the surface of live cells can be functionalized to display polyvalent biomolecular structures through two-step reactions under physiological conditions. This polyvalent functionalization enables the cell surface to recognize the microenvironment one order of magnitude more effectively than with monovalent functionalization. Thus, polyvalent display of biomolecules on live cells holds great potential for various biological and biomedical applications. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. PENGARUH DISPLAY PRODUK PADA KEPUTUSAN PEMBELIAN KONSUMEN

    Directory of Open Access Journals (Sweden)

    Ina Melati

    2012-11-01

    Full Text Available Most of ritel outlet recently using product display as a one of their best marketing strategy, the reason is quiet easy to be understood, since consumers are too easy to be teased by those kind of beautiful product display that is being displayed by the retail outlet. The good retail outlets are trying their best to design and make the very good product display, so they can attract more consumers and make them not thinking twice to visit their store and purchase lots of thing. Clearly seeing that an attractive product design is able to influence a consumer to make a buying decision. 

  5. Pilot stereotypes for navigation symbols on electronic displays

    Science.gov (United States)

    2006-09-20

    There is currently no common symbology standard for the : electronic display of navigation information. The wide : range of display technologies and the different functions : these displays support make it difficult to design symbols : that are easil...

  6. An inexpensive modification of the laboratory computer display changes emergency physicians' work habits and perceptions.

    Science.gov (United States)

    Marinakis, Harry A; Zwemer, Frank L

    2003-02-01

    Little is known about how the availability of laboratory data affects emergency physicians' practice habits and satisfaction. We modified our clinical information system to display laboratory test status with continuous updates, similar to an airport arrival display. The objective of this study was to determine whether the laboratory test status display altered emergency physicians' work habits and increased satisfaction compared with the time period before implementation of laboratory test status. A retrospective analysis was performed of emergency physicians' actual use of the clinical information system before and after implementation of the laboratory test status display. Emergency physicians were retrospectively surveyed regarding the effect of laboratory test status display on their practice habits and clinical information system use. Survey responses were matched with actual use of the clinical information system. Data were analyzed by using dependent t tests and Pearson correlation coefficients. The study was conducted at a university hospital. Clinical information system use by 46 emergency physicians was analyzed. Twenty-five surveys were returned (71.4% of available emergency physicians). All emergency physicians perceived fewer clinical information system log ons per day after laboratory test status display. The actual average decrease was 19%. Emergency physicians who reported the greatest decrease in log ons per day tended to have the greatest actual decrease (r =-0.36). There was no significant correlation between actual and perceived total time logged on (r =0.08). In regard to effect on emergency physicians' practice habits, 95% reported increased efficiency, 80% reported improved satisfaction with data access, and 65% reported improved communication with patients. An inexpensive computer modification, laboratory test status display, significantly increased subjective efficiency, changed work habits, and improved satisfaction regarding data access

  7. Evaluating Ambient Displays in the Wild

    DEFF Research Database (Denmark)

    Messeter, Jörn; Molenaar, Daryn

    A prominent issue for evaluating ambient displays has been the conflict between the relative intrusiveness of evaluation methods and the intention to keep the display at the periphery of the user’s attention. There is a general lack of research discussing the difficulties of evaluating ambient di...

  8. Tilt-effect of holograms and images displayed on a spatial light modulator.

    Science.gov (United States)

    Harm, Walter; Roider, Clemens; Bernet, Stefan; Ritsch-Marte, Monika

    2015-11-16

    We show that a liquid crystal spatial light modulator (LCOS-SLM) can be used to display amplitude images, or phase holograms, which change in a pre-determined way when the display is tilted, i.e. observed under different angles. This is similar to the tilt-effect (also called "latent image effect") known from various security elements ("kinegrams") on credit cards or bank notes. The effect is achieved without any specialized optical components, simply by using the large phase shifting capability of a "thick" SLM, which extends over several multiples of 2π, in combination with the angular dependence of the phase shift. For hologram projection one can use the fact that the phase of a monochromatic wave is only defined modulo 2π. Thus one can design a phase pattern extending over several multiples of 2π, which transforms at different readout angles into different 2π-wrapped phase structures, due to the angular dependence of the modulo 2π operation. These different beams then project different holograms at the respective readout angles. In amplitude modulation mode (with inserted polarizer) the intensity of each SLM pixel oscillates over several periods when tuning its control voltage. Since the oscillation period depends on the readout angle, it is possible to find a certain control voltage which produces two (or more) selectable gray levels at a corresponding number of pre-determined readout angles. This is done with all SLM pixels individually, thus constructing different images for the selected angles. We experimentally demonstrate the reconstruction of multiple (Fourier- and Fresnel-) holograms, and of different amplitude images, by readout of static diffractive patterns in a variable angular range between 0° and 60°.

  9. Panoramic, large-screen, 3-D flight display system design

    Science.gov (United States)

    Franklin, Henry; Larson, Brent; Johnson, Michael; Droessler, Justin; Reinhart, William F.

    1995-01-01

    The report documents and summarizes the results of the required evaluations specified in the SOW and the design specifications for the selected display system hardware. Also included are the proposed development plan and schedule as well as the estimated rough order of magnitude (ROM) cost to design, fabricate, and demonstrate a flyable prototype research flight display system. The thrust of the effort was development of a complete understanding of the user/system requirements for a panoramic, collimated, 3-D flyable avionic display system and the translation of the requirements into an acceptable system design for fabrication and demonstration of a prototype display in the early 1997 time frame. Eleven display system design concepts were presented to NASA LaRC during the program, one of which was down-selected to a preferred display system concept. A set of preliminary display requirements was formulated. The state of the art in image source technology, 3-D methods, collimation methods, and interaction methods for a panoramic, 3-D flight display system were reviewed in depth and evaluated. Display technology improvements and risk reductions associated with maturity of the technologies for the preferred display system design concept were identified.

  10. White constancy method for mobile displays

    Science.gov (United States)

    Yum, Ji Young; Park, Hyun Hee; Jang, Seul Ki; Lee, Jae Hyang; Kim, Jong Ho; Yi, Ji Young; Lee, Min Woo

    2014-03-01

    In these days, consumer's needs for image quality of mobile devices are increasing as smartphone is widely used. For example, colors may be perceived differently when displayed contents under different illuminants. Displayed white in incandescent lamp is perceived as bluish, while same content in LED light is perceived as yellowish. When changed in perceived white under illuminant environment, image quality would be degraded. Objective of the proposed white constancy method is restricted to maintain consistent output colors regardless of the illuminants utilized. Human visual experiments are performed to analyze viewers'perceptual constancy. Participants are asked to choose the displayed white in a variety of illuminants. Relationship between the illuminants and the selected colors with white are modeled by mapping function based on the results of human visual experiments. White constancy values for image control are determined on the predesigned functions. Experimental results indicate that propsed method yields better image quality by keeping the display white.

  11. Safety parameter display systems' effect on operator performance

    International Nuclear Information System (INIS)

    Cerven, F.; Ford, R.E.; Blackman, H.S.

    1983-01-01

    Computer generated displays are a powerful and flexible tool for presenting data to the operators of nuclear power plants. Such displays are currently being developed in industry for use as safety parameter displays and for use in advanced control rooms. There exists a need for methods to objectively evaluate the effect of these displays, positive or negative, on the performance of control room personnel. Results of developing one such method, noninteractive simulation, and the two experiments that were performed to determine if it can be used as a method for evaluating computer displays are presented. This method is more objective and powerful than pencil and paper methods because it measures human performance rather than opinion or perference, has excellent control of the experimental variables, and has a higher fidelity to the control room environment. The results of these experiments indicates that the present methodology does not differentiate among the display types tested at a statistically significant level. In other words, all display types tested worked equally well in providing operators needed information

  12. Investigating pointing tasks across angularly coupled display areas

    DEFF Research Database (Denmark)

    Hennecke, Fabian; De Luca, Alexander; Nguyen, Ngo Dieu Huong

    2013-01-01

    Pointing tasks are a crucial part of today’s graphical user interfaces. They are well understood for flat displays and most prominently are modeled through Fitts’ Law. For novel displays (e.g., curved displays with multi-purpose areas), however, it remains unclear whether such models for predicting...... that the target position affects overall pointing speed and offset in both conditions. However, we also found that Fitts’ Law can in fact still be used to predict performance as on flat displays. Our results help designers to optimize user interfaces on angularly coupled displays when pointing tasks are involved....... user performance still hold – in particular when pointing is performed across differently oriented areas. To answer this question, we conducted an experiment on an angularly coupled display – the Curve – with two input conditions: direct touch and indirect mouse pointer. Our findings show...

  13. Considerations for the composition of visual scene displays: potential contributions of information from visual and cognitive sciences.

    Science.gov (United States)

    Wilkinson, Krista M; Light, Janice; Drager, Kathryn

    2012-09-01

    Aided augmentative and alternative (AAC) interventions have been demonstrated to facilitate a variety of communication outcomes in persons with intellectual disabilities. Most aided AAC systems rely on a visual modality. When the medium for communication is visual, it seems likely that the effectiveness of intervention depends in part on the effectiveness and efficiency with which the information presented in the display can be perceived, identified, and extracted by communicators and their partners. Understanding of visual-cognitive processing - that is, how a user attends, perceives, and makes sense of the visual information on the display - therefore seems critical to designing effective aided AAC interventions. In this Forum Note, we discuss characteristics of one particular type of aided AAC display, that is, Visual Scene Displays (VSDs) as they may relate to user visual and cognitive processing. We consider three specific ways in which bodies of knowledge drawn from the visual cognitive sciences may be relevant to the composition of VSDs, with the understanding the direct research with children with complex communication needs is necessary to verify or refute our speculations.

  14. User interface design in safety parameter display systems

    International Nuclear Information System (INIS)

    Schultz, E.E. Jr.; Johnson, G.L.

    1988-01-01

    The extensive installation of computerized safety Parameter Display Systems (SPDSs) in nuclear power plants since the Three-Mile Island accident has enhanced plant safety. It has also raised new issues of how best to ensure an effective interface between human operators and the plant via computer systems. New developments in interface technologies since the current generation of SPDSs was installed can contribute to improving display interfaces. These technologies include new input devices, three-dimensional displays, delay indicators, and auditory displays. Examples of how they might be applied to improve current SPDSs are given. These examples illustrate how the new use interface technology could be applied to future nuclear plant displays

  15. In roots of Arabidopsis thaliana, the damage-associated molecular pattern AtPep1 is a stronger elicitor of immune signalling than flg22 or the chitin heptamer.

    Directory of Open Access Journals (Sweden)

    Lorenzo Poncini

    Full Text Available Plants interpret their immediate environment through perception of small molecules. Microbe-associated molecular patterns (MAMPs such as flagellin and chitin are likely to be more abundant in the rhizosphere than plant-derived damage-associated molecular patterns (DAMPs. We investigated how the Arabidopsis thaliana root interprets MAMPs and DAMPs as danger signals. We monitored root development during exposure to increasing concentrations of the MAMPs flg22 and the chitin heptamer as well as of the DAMP AtPep1. The tissue-specific expression of defence-related genes in roots was analysed using a toolkit of promoter::YFPN lines reporting jasmonic acid (JA-, salicylic acid (SA-, ethylene (ET- and reactive oxygen species (ROS- dependent signalling. Finally, marker responses were analysed during invasion by the root pathogen Fusarium oxysporum. The DAMP AtPep1 triggered a stronger activation of the defence markers compared to flg22 and the chitin heptamer. In contrast to the tested MAMPs, AtPep1 induced SA- and JA-signalling markers in the root and caused a severe inhibition of root growth. Fungal attack resulted in a strong activation of defence genes in tissues close to the invading fungal hyphae. The results collectively suggest that AtPep1 presents a stronger danger signal to the Arabidopsis root than the MAMPs flg22 and chitin heptamer.

  16. Position display device

    International Nuclear Information System (INIS)

    Nishizawa, Yukio.

    1974-01-01

    Object: To provide a device capable of easily and quickly reading mutual mounting relations of control bodies such as control rods mounted on a nuclear reactor and positions to which the control bodies are driven. Structure: A scanning circuit is provided to scan positions of controllably mounted control bodies such as control rods. Values detected by scanning the positions are converted into character signals according to the values and converted into preranked color signals. The character signals and color signals are stored in a memory circuit by synchronous signals in synchronism with the scanning in the scanning circuit. Outputs of the memory circuit are displayed by a display unit such as a color Braun tube in accordance with the synchronous signals to provide color representations according to positions to which control bodies are driven in the same positional relation as the mounting of the control bodies. (Kamimura, M.)

  17. Ocular Tolerance of Contemporary Electronic Display Devices.

    Science.gov (United States)

    Clark, Andrew J; Yang, Paul; Khaderi, Khizer R; Moshfeghi, Andrew A

    2018-05-01

    Electronic displays have become an integral part of life in the developed world since the revolution of mobile computing a decade ago. With the release of multiple consumer-grade virtual reality (VR) and augmented reality (AR) products in the past 2 years utilizing head-mounted displays (HMDs), as well as the development of low-cost, smartphone-based HMDs, the ability to intimately interact with electronic screens is greater than ever. VR/AR HMDs also place the display at much closer ocular proximity than traditional electronic devices while also isolating the user from the ambient environment to create a "closed" system between the user's eyes and the display. Whether the increased interaction with these devices places the user's retina at higher risk of damage is currently unclear. Herein, the authors review the discovery of photochemical damage of the retina from visible light as well as summarize relevant clinical and preclinical data regarding the influence of modern display devices on retinal health. Multiple preclinical studies have been performed with modern light-emitting diode technology demonstrating damage to the retina at modest exposure levels, particularly from blue-light wavelengths. Unfortunately, high-quality in-human studies are lacking, and the small clinical investigations performed to date have failed to keep pace with the rapid evolutions in display technology. Clinical investigations assessing the effect of HMDs on human retinal function are also yet to be performed. From the available data, modern consumer electronic displays do not appear to pose any acute risk to vision with average use; however, future studies with well-defined clinical outcomes and illuminance metrics are needed to better understand the long-term risks of cumulative exposure to electronic displays in general and with "closed" VR/AR HMDs in particular. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:346-354.]. Copyright 2018, SLACK Incorporated.

  18. 27 CFR 6.55 - Display service.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Display service. 6.55 Section 6.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS âTIED-HOUSEâ Unlawful Inducements Paying for Advertising, Display Or...

  19. AUTOET code (a code for automatically constructing event trees and displaying subsystem interdependencies)

    International Nuclear Information System (INIS)

    Wilson, J.R.; Burdick, G.R.

    1977-06-01

    This is a user's manual for AUTOET I and II. AUTOET I is a computer code for automatic event tree construction. It is designed to incorporate and display subsystem interdependencies and common or key component dependencies in the event tree format. The code is written in FORTRAN IV for the CDC Cyber 76 using the Integrated Graphics System (IGS). AUTOET II incorporates consequence and risk calculations, in addition to some other refinements. 5 figures

  20. Radon daughters and work at display devices

    International Nuclear Information System (INIS)

    Falk, R.; Nyblom, L.

    1986-01-01

    It has been shown that ions and electrically charged particles in the air can be transported in the electrostatic field between a face and a display device to either the face or the screen. Radon daughters can occur as ions, or sitting on charged particles. This prestudy shows that radon daughters were manifold concentrated on the face of a doll placed in front of a display device, or in a electrostatic field of the kind typical for displaying devices. The radiation dose, in the skin from the radon daughters in an ordinary office environment plus the addition caused by work at a display device, is not strong enough to cause skin damages alone. (BoK)

  1. A display to support knowledge based behavior

    International Nuclear Information System (INIS)

    Lindsay, R.W.

    1990-01-01

    A computerized display has been created for the Experimental Breeder Reactor II (EBR-II) that incorporates information from plant sensors in a thermodynamic model display. The display is designed to provide an operator with an overall view of the plant process as a heat engine. The thermodynamics of the plant are depicted through the use of ionic figures, animated by plant signals, that are related to the major plant components and systems such as the reactor, intermediate heat exchanger, secondary system, evaporators, superheaters, steam system, steam drum, and turbine-generator. This display supports knowledge based reasoning for the operator as well as providing the traditional rule and skill based behavior, and includes side benefits such a inherent signal validation

  2. An update on zolpidem abuse and dependence.

    Science.gov (United States)

    Victorri-Vigneau, Caroline; Gérardin, Marie; Rousselet, Morgane; Guerlais, Marylène; Grall-Bronnec, Marie; Jolliet, Pascale

    2014-01-01

    In 2004, the health authorities (French National Agency for Medicines and Health Products Safety-ANSM) modified the summary of zolpidem characteristics. Particularly it now includes the sentence "a pharmacodependence may materialize." The current article aims to show that despite this modification, zolpidem continues to be associated with problematic drug use, as the official system (Center for Evaluation and Information on Pharmacodependence-Addictovigilance network) providing information on the abuse and dependence potential of drugs informs us. The authors reviewed the literature on this topic and analyzed French data from zolpidem's postmarketing period that were collected by the Addictovigilance network from 2003 to 2010. Postmarketing data and the 30 case reports yielded from the literature review highlight a significant dependence and abuse potential for zolpidem. This survey led to propose in stronger additional rules in France to try to mitigate the abuse potential of zolpidem.

  3. Optimizing height presentation for aircraft cockpit displays

    Science.gov (United States)

    Jordan, Chris S.; Croft, D.; Selcon, Stephen J.; Markin, H.; Jackson, M.

    1997-02-01

    This paper describes an experiment conducted to investigate the type of display symbology that most effectively conveys height information to users of head-down plan-view radar displays. The experiment also investigated the use of multiple information sources (redundancy) in the design of such displays. Subjects were presented with eight different height display formats. These formats were constructed from a control, and/or one, two, or three sources of redundant information. The three formats were letter coding, analogue scaling, and toggling (spatially switching the position of the height information from above to below the aircraft symbol). Subjects were required to indicate altitude awareness via a four-key, forced-choice keyboard response. Error scores and response times were taken as performance measures. There were three main findings. First, there was a significant performance advantage when the altitude information was presented above and below the symbol to aid the representation of height information. Second, the analogue scale, a line whose length indicated altitude, proved significantly detrimental to performance. Finally, no relationship was found between the number of redundant information sources employed and performance. The implications for future aircraft and displays are discussed in relation to current aircraft tactical displays and in the context of perceptual psychological theory.

  4. View interpolation for medical images on autostereoscopic displays

    NARCIS (Netherlands)

    Zinger, S.; Ruijters, D.; Do, Q.L.; With, de P.H.N.

    2012-01-01

    We present an approach for efficient rendering and transmitting views to a high-resolution autostereoscopic display for medical purposes. Displaying biomedical images on an autostereoscopic display poses different requirements than in a consumer case. For medical usage, it is essential that the

  5. Cholesteric Liquid Crystal Based Reflex Color Reflective Displays

    Science.gov (United States)

    Khan, Asad

    2012-02-01

    Bistable color cholesteric liquid crystal displays are unique LCDs that exhibit high reflectivity, good contrast, extremely low power operation, and are amenable to versatile roll-to-roll manufacturing. The display technology, now branded as Reflex has been in commercialized products since 1996. It has been the subject of extensive research and development globally by a variety of parties in both academic and industrial settings. Today, the display technology is in volume production for applications such as dedicated eWriters (Boogie Board), full color electronic skins (eSkin), and displays for smart cards. The flexibility comes from polymerization induced phase separation using unique materials unparalleled in any other display technology. The blend of monomers, polymers, cross linkers, and other components along with nematic liquid crystals and chiral dopants is created and processed in such ways so as to enable highly efficient manufactrable displays using ultra thin plastic substrates -- often as thin as 50μm. Other significant aspects include full color by stacking or spatial separation, night vision capability, ultra high resolution, as well as active matrix capabilities. Of particular note is the stacking approach of Reflex based displays to show full color. This approach for reflective color displays is unique to this technology. Owing to high transparency in wavelength bands outside the selective reflection band, three primarily color layers can be stacked on top of each other and reflect without interfering with other layers. This highly surprising architecture enables the highest reflectivity of any other reflective electronic color display technology. The optics, architecture, electro-topics, and process techniques will be discussed. This presentation will focus on the physics of the core technology and color, it's evolution from rigid glass based displays to flexible displays, development of products from the paradigm shifting concepts to consumer

  6. Interactive editing program using display

    International Nuclear Information System (INIS)

    Lang, I.; Ehsenski, J.; Namsraj, Yu.; Fefilov, B.V.

    1976-01-01

    A general description is given as well as principal functions are considered of 'DOSE' interactive editor program with a display involved. The program has been elaborated for TRA/1-1001 computer. This program enables one to edit and correct texts in algorithmical languages on a raster display screen as well as to provide perforated tapes for their further usage. 'DOSE' program is regarded as a basic program system for a set of TRA/1 and MINSK-32 computers

  7. Evaluating stereoscopic displays: both efficiency measures and perceived workload sensitive to manipulations in binocular disparity

    Science.gov (United States)

    van Beurden, Maurice H. P. H.; Ijsselsteijn, Wijnand A.; de Kort, Yvonne A. W.

    2011-03-01

    Stereoscopic displays are known to offer a number of key advantages in visualizing complex 3D structures or datasets. The large majority of studies that focus on evaluating stereoscopic displays for professional applications use completion time and/or the percentage of correct answers to measure potential performance advantages. However, completion time and accuracy may not fully reflect all the benefits of stereoscopic displays. In this paper, we argue that perceived workload is an additional valuable indicator reflecting the extent to which users can benefit from using stereoscopic displays. We performed an experiment in which participants were asked to perform a visual path-tracing task within a convoluted 3D wireframe structure, varying in level of complexity of the visualised structure and level of disparity of the visualisation. The results showed that an optimal performance (completion time, accuracy and workload), depend both on task difficulty and disparity level. Stereoscopic disparity revealed a faster and more accurate task performance, whereas we observed a trend that performance on difficult tasks stands to benefit more from higher levels of disparity than performance on easy tasks. Perceived workload (as measured using the NASA-TLX) showed a similar response pattern, providing evidence that perceived workload is sensitive to variations in disparity as well as task difficulty. This suggests that perceived workload could be a useful concept, in addition to standard performance indicators, in characterising and measuring human performance advantages when using stereoscopic displays.

  8. Small - Display Cartography

    DEFF Research Database (Denmark)

    Nissen, Flemming; Hvas, Anders; Münster-Swendsen, Jørgen

    Service Communication and finally, Part IV: Concluding remarks and topics for further research on small-display cartography. Part II includes a separate Appendix D consisting of a cartographic design specification. Part III includes a separate Appendix C consisting of a schema specification, a separate...

  9. Wired World-Wide Web Interactive Remote Event Display

    Energy Technology Data Exchange (ETDEWEB)

    De Groot, Nicolo

    2003-05-07

    WIRED (World-Wide Web Interactive Remote Event Display) is a framework, written in the Java{trademark} language, for building High Energy Physics event displays. An event display based on the WIRED framework enables users of a HEP collaboration to visualize and analyze events remotely using ordinary WWW browsers, on any type of machine. In addition, event displays using WIRED may provide the general public with access to the research of high energy physics. The recent introduction of the object-oriented Java{trademark} language enables the transfer of machine independent code across the Internet, to be safely executed by a Java enhanced WWW browser. We have employed this technology to create a remote event display in WWW. The combined Java-WWW technology hence assures a world wide availability of such an event display, an always up-to-date program and a platform independent implementation, which is easy to use and to install.

  10. Optimizing direct response in Internet display advertising

    OpenAIRE

    Aksakallı, Vural

    2013-01-01

    Internet display advertising has grown into a multi-billion dollar a year global industry and direct response campaigns account for about three-quarters of all Internet display advertising. In such campaigns, advertisers reach out to a target audience via some form of a visual advertisement (hereinafter also called “ad”) to maximize short-term sales revenue. In this study, we formulate an advertiser’s revenue maximization problem in direct response Internet display advertisement campaigns as ...

  11. Online Display Advertising Causal Attribution and Evaluation

    OpenAIRE

    Barajas Zamora, Joel

    2015-01-01

    The allocation of a given budget to online display advertising as a marketing channel has motivated the development of statistical methods to measure its effectiveness. Recent studies show that display advertising often triggers online users to search for more information on products. Eventually, many of these users convert at the advertiser’s website. A key challenge is to measure the effectiveness of display advertising when users are exposed to multiple unknown advertising channels.We deve...

  12. Methods and apparatus for transparent display using scattering nanoparticles

    Science.gov (United States)

    Hsu, Chia Wei; Qiu, Wenjun; Zhen, Bo; Shapira, Ofer; Soljacic, Marin

    2016-05-10

    Transparent displays enable many useful applications, including heads-up displays for cars and aircraft as well as displays on eyeglasses and glass windows. Unfortunately, transparent displays made of organic light-emitting diodes are typically expensive and opaque. Heads-up displays often require fixed light sources and have limited viewing angles. And transparent displays that use frequency conversion are typically energy inefficient. Conversely, the present transparent displays operate by scattering visible light from resonant nanoparticles with narrowband scattering cross sections and small absorption cross sections. More specifically, projecting an image onto a transparent screen doped with nanoparticles that selectively scatter light at the image wavelength(s) yields an image on the screen visible to an observer. Because the nanoparticles scatter light at only certain wavelengths, the screen is practically transparent under ambient light. Exemplary transparent scattering displays can be simple, inexpensive, scalable to large sizes, viewable over wide angular ranges, energy efficient, and transparent simultaneously.

  13. Array display tool ADT reference manual. Version 1.2

    International Nuclear Information System (INIS)

    Evans, K. Jr.

    1995-12-01

    Array Display Tool (ADT) is a Motif program to display arrays of process variables from the Advanced Photon Source control system. A typical use is to display the horizontal and vertical monitor readings. A picture of the ADT interface is here. The screen layout, apart from the menu bar, consists of two types of graphic areas in which the values for the arrays of process variables are shown: Display areas, which display one or more arrays as a function of index, and a zoom area. In the zoom area specified arrays only are displayed as a function of lattice position along with symbols for the major elements of the lattice. There can be several display areas, but at most one zoom area. When the screen is resized these areas change size proportionally. There are a number of options in the View Menu to change the way the values are displayed. It is also possible via the Options Menu to: (1) Store the current values internally. (2) Store the values from a snapshot file internally. (3) Display one of the stored sets of values along with the current values. (4) Display the difference of the current values with one of the stored sets of values. (5) Write the current values to a snapshot file. There are several (currently 5) slots in which you can store values internally. In addition you can display the values with specified reference values subtracted

  14. Young Children's Responses to Guilt Displays

    Science.gov (United States)

    Vaish, Amrisha; Carpenter, Malinda; Tomasello, Michael

    2011-01-01

    Displaying guilt after a transgression serves to appease the victim and other group members, restore interpersonal relationships, and indicate the transgressors' awareness of and desire to conform to the group's norms. We investigated whether and when young children are sensitive to these functions of guilt displays. In Study 1, after 4- and…

  15. Pervasive displays understanding the future of digital signage

    CERN Document Server

    Davies, Nigel; Alt, Florian

    2014-01-01

    Fueled by falling display hardware costs and rising demand, digital signage and pervasive displays are becoming ever more ubiquitous. Such systems have traditionally been used for advertising and information dissemination, with digital signage commonplace in shopping malls, airports and public spaces. While advertising and broadcasting announcements remain important applications, developments in sensing and interaction technologies are enabling entirely new classes of display applications that tailor content to the situation and audience of the display. As a result, signage systems are beginni

  16. Securing information display by use of visual cryptography.

    Science.gov (United States)

    Yamamoto, Hirotsugu; Hayasaki, Yoshio; Nishida, Nobuo

    2003-09-01

    We propose a secure display technique based on visual cryptography. The proposed technique ensures the security of visual information. The display employs a decoding mask based on visual cryptography. Without the decoding mask, the displayed information cannot be viewed. The viewing zone is limited by the decoding mask so that only one person can view the information. We have developed a set of encryption codes to maintain the designed viewing zone and have demonstrated a display that provides a limited viewing zone.

  17. Plant diversity increases with the strength of negative density dependence at the global scale

    Science.gov (United States)

    LaManna, Joseph A.; Mangan, Scott A.; Alonso, Alfonso; Bourg, Norman; Brockelman, Warren Y.; Bunyavejchewin, Sarayudh; Chang, Li-Wan; Chiang, Jyh-Min; Chuyong, George B.; Clay, Keith; Condit, Richard; Cordell, Susan; Davies, Stuart J.; Furniss, Tucker J.; Giardina, Christian P.; Gunatilleke, I.A.U. Nimal; Gunatilleke, C.V. Savitri; He, Fangliang; Howe, Robert W.; Hubbell, Stephen P.; Hsieh, Chang-Fu; Inman-Narahari, Faith M.; Janik, David; Johnson, Daniel J.; Kenfack, David; Korte, Lisa; Kral, Kamil; Larson, Andrew J.; Lutz, James A.; McMahon, Sean M.; McShea, William J.; Memiaghe, Herve R.; Nathalang, Anuttara; Novotny, Vojtech; Ong, Perry S.; Orwig, David A.; Ostertag, Rebecca; Parker, Geoffrey G.; Phillips, Richard P.; Sack, Lawren; Sun, I-Fang; Tello, J. Sebastian; Thomas, Duncan W.; Turner, Benjamin L.; Vela Diaz, Dilys M.; Vrska, Tomas; Weiblen, George D.; Wolf, Amy; Yap, Sandra; Myers, Jonathan A.

    2017-01-01

    Theory predicts that higher biodiversity in the tropics is maintained by specialized interactions among plants and their natural enemies that result in conspecific negative density dependence (CNDD). By using more than 3000 species and nearly 2.4 million trees across 24 forest plots worldwide, we show that global patterns in tree species diversity reflect not only stronger CNDD at tropical versus temperate latitudes but also a latitudinal shift in the relationship between CNDD and species abundance. CNDD was stronger for rare species at tropical versus temperate latitudes, potentially causing the persistence of greater numbers of rare species in the tropics. Our study reveals fundamental differences in the nature of local-scale biotic interactions that contribute to the maintenance of species diversity across temperate and tropical communities.

  18. Unit information system operational displays for VVER-1000 reactors

    International Nuclear Information System (INIS)

    Anikanov, S.S.; Carrera, J.P.; Gordon, P.

    1997-01-01

    The role of high level operational displays is explained as well as the principles of the design of such displays. The tasks of WWER operating personnel are described and the support provided by operational displays is highlighted. The architecture of the displays is also dealt with. (A.K.)

  19. A display to support knowledge based behavior

    International Nuclear Information System (INIS)

    Lindsay, R.W.

    1990-01-01

    This paper reports on a computerized display that has been created for the Experimental Breeder Reactor II that incorporates information from plant sensors in a thermodynamic model display. The display is designed to provide an operator with an overall view of the plant process as a heat engine. The thermodynamics of the plant are depicted through the use of iconic figures, animated by plant signals, that are related to the major plant components and systems such as the reactor, intermediate heat exchanger, secondary system, evaporators, superheaters, steam system, steam drum, and turbine-generator. This display supports knowledge based reasoning for the operator as well as providing data for the traditional rule and skill based behavior, and includes side benefits such as inherent signal validation

  20. Policies toward advanced display in the Clinton administration

    Science.gov (United States)

    Hart, Jeffrey A.

    1994-04-01

    The Clinton administration is using its policy toward advanced displays as a test case for making industry-specific policies. They have established a number of criteria for advanced displays that they hope to apply to other industries in the future. For example, they want to support the development of generic technologies through ARPA and NIST, while minimizing the government's role in key business decisions. They want the industry (by which they mean the tool makers, the component assemblers, and the systems firms) to agree internally before they go ahead with their promotional policies. Given the past history of the advanced display industry, especially its disunity in regard to the enforcement of the successful antidumping petition of the Advanced Display Manufacturers Association and to efforts to create the U.S. Display Consortium, these criteria will be hard to meet. Nevertheless, there now appears to be much greater consensus among the three groups than in the past on the need to build indigenous technological capabilities in advanced displays.

  1. Attention-dependent modulation of cortical taste circuits revealed by Granger causality with signal-dependent noise.

    Directory of Open Access Journals (Sweden)

    Qiang Luo

    2013-10-01

    Full Text Available We show, for the first time, that in cortical areas, for example the insular, orbitofrontal, and lateral prefrontal cortex, there is signal-dependent noise in the fMRI blood-oxygen level dependent (BOLD time series, with the variance of the noise increasing approximately linearly with the square of the signal. Classical Granger causal models are based on autoregressive models with time invariant covariance structure, and thus do not take this signal-dependent noise into account. To address this limitation, here we describe a Granger causal model with signal-dependent noise, and a novel, likelihood ratio test for causal inferences. We apply this approach to the data from an fMRI study to investigate the source of the top-down attentional control of taste intensity and taste pleasantness processing. The Granger causality with signal-dependent noise analysis reveals effects not identified by classical Granger causal analysis. In particular, there is a top-down effect from the posterior lateral prefrontal cortex to the insular taste cortex during attention to intensity but not to pleasantness, and there is a top-down effect from the anterior and posterior lateral prefrontal cortex to the orbitofrontal cortex during attention to pleasantness but not to intensity. In addition, there is stronger forward effective connectivity from the insular taste cortex to the orbitofrontal cortex during attention to pleasantness than during attention to intensity. These findings indicate the importance of explicitly modeling signal-dependent noise in functional neuroimaging, and reveal some of the processes involved in a biased activation theory of selective attention.

  2. A programmable display layer for virtual reality system architectures.

    Science.gov (United States)

    Smit, Ferdi Alexander; van Liere, Robert; Froehlich, Bernd

    2010-01-01

    Display systems typically operate at a minimum rate of 60 Hz. However, existing VR-architectures generally produce application updates at a lower rate. Consequently, the display is not updated by the application every display frame. This causes a number of undesirable perceptual artifacts. We describe an architecture that provides a programmable display layer (PDL) in order to generate updated display frames. This replaces the default display behavior of repeating application frames until an update is available. We will show three benefits of the architecture typical to VR. First, smooth motion is provided by generating intermediate display frames by per-pixel depth-image warping using 3D motion fields. Smooth motion eliminates various perceptual artifacts due to judder. Second, we implement fine-grained latency reduction at the display frame level using a synchronized prediction of simulation objects and the viewpoint. This improves the average quality and consistency of latency reduction. Third, a crosstalk reduction algorithm for consecutive display frames is implemented, which improves the quality of stereoscopic images. To evaluate the architecture, we compare image quality and latency to that of a classic level-of-detail approach.

  3. A multi-viewer tiled autostereoscopic virtual reality display

    KAUST Repository

    Kooima, Robert; Prudhomme, Andrew; Schulze, Jurgen; Sandin, Daniel; DeFanti, Thomas

    2010-01-01

    Recognizing the value of autostereoscopy for 3D displays in public contexts, we pursue the goal of large-scale, high-resolution, immersive virtual reality using lenticular displays. Our contributions include the scalable tiling of lenticular displays to large fields of view and the use of GPU image interleaving and application optimization for real-time performance. In this context, we examine several ways to improve group-viewing by combining user tracking with multi-view displays. Copyright © 2010 by the Association for Computing Machinery, Inc.

  4. Aquaglyceroporin-null trypanosomes display glycerol transport defects and respiratory-inhibitor sensitivity.

    Directory of Open Access Journals (Sweden)

    Laura Jeacock

    2017-03-01

    Full Text Available Aquaglyceroporins (AQPs transport water and glycerol and play important roles in drug-uptake in pathogenic trypanosomatids. For example, AQP2 in the human-infectious African trypanosome, Trypanosoma brucei gambiense, is responsible for melarsoprol and pentamidine-uptake, and melarsoprol treatment-failure has been found to be due to AQP2-defects in these parasites. To further probe the roles of these transporters, we assembled a T. b. brucei strain lacking all three AQP-genes. Triple-null aqp1-2-3 T. b. brucei displayed only a very moderate growth defect in vitro, established infections in mice and recovered effectively from hypotonic-shock. The aqp1-2-3 trypanosomes did, however, display glycerol uptake and efflux defects. They failed to accumulate glycerol or to utilise glycerol as a carbon-source and displayed increased sensitivity to salicylhydroxamic acid (SHAM, octyl gallate or propyl gallate; these inhibitors of trypanosome alternative oxidase (TAO can increase intracellular glycerol to toxic levels. Notably, disruption of AQP2 alone generated cells with glycerol transport defects. Consistent with these findings, AQP2-defective, melarsoprol-resistant clinical isolates were sensitive to the TAO inhibitors, SHAM, propyl gallate and ascofuranone, relative to melarsoprol-sensitive reference strains. We conclude that African trypanosome AQPs are dispensable for viability and osmoregulation but they make important contributions to drug-uptake, glycerol-transport and respiratory-inhibitor sensitivity. We also discuss how the AQP-dependent inverse sensitivity to melarsoprol and respiratory inhibitors described here might be exploited.

  5. An Advanced Diagnostic Display for Core Protection Calculator System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji-Hyeon; Jeong, See-Chae; Sohn, Se-Do [Korea Power Engineering Company, Daejeon (Korea, Republic of)

    2008-10-15

    The main purpose of a Nuclear Power Plant Instrumentation and Control (I and C) Display System is to provide operator's interface for I and C systems. The CPCS display(Shin-Kori 1 and 2) provides operators with 1) plant monitoring values of field input and algorithm variables that reflect the reactor core conditions, 2) operation values that operators can change and 3) CPCS status. It will be an optimal case if operators can understand the plant (including CPCS itself) condition intuitively with the displayed values but it is not easy in CPCS. For example, if the CPCS Channel Trouble light is lit, operators need some amount of time to investigate what caused the trouble light because there are more than hundred causes that can generate the channel trouble. If a Display supports diagnostic information that shows what cause the displayed alarms, it will greatly help operators in easy understanding the CPCS status. To provide these diagnostic information, this paper suggests an active self-explanatory display mechanism. This self-explanatory diagnostic display mechanism utilizes an ontology in XML that describes parent child, sibling relationships of display variables, through which in-depth, in-breadth diagnostic tracking is possible. This paper consists of two parts. First, the key features of CPCS Flat Panel Display System (FPDS) are described. Second, the features of active self explanatory diagnostic display are discussed.

  6. An Advanced Diagnostic Display for Core Protection Calculator System

    International Nuclear Information System (INIS)

    Kim, Ji-Hyeon; Jeong, See-Chae; Sohn, Se-Do

    2008-01-01

    The main purpose of a Nuclear Power Plant Instrumentation and Control (I and C) Display System is to provide operator's interface for I and C systems. The CPCS display(Shin-Kori 1 and 2) provides operators with 1) plant monitoring values of field input and algorithm variables that reflect the reactor core conditions, 2) operation values that operators can change and 3) CPCS status. It will be an optimal case if operators can understand the plant (including CPCS itself) condition intuitively with the displayed values but it is not easy in CPCS. For example, if the CPCS Channel Trouble light is lit, operators need some amount of time to investigate what caused the trouble light because there are more than hundred causes that can generate the channel trouble. If a Display supports diagnostic information that shows what cause the displayed alarms, it will greatly help operators in easy understanding the CPCS status. To provide these diagnostic information, this paper suggests an active self-explanatory display mechanism. This self-explanatory diagnostic display mechanism utilizes an ontology in XML that describes parent child, sibling relationships of display variables, through which in-depth, in-breadth diagnostic tracking is possible. This paper consists of two parts. First, the key features of CPCS Flat Panel Display System (FPDS) are described. Second, the features of active self explanatory diagnostic display are discussed

  7. Dependence between sea surge, river flow and precipitation in south and west Britain

    Directory of Open Access Journals (Sweden)

    C. Svensson

    2004-01-01

    northwards has slightly stronger flow-surge dependence in summer than in winter, whereas dependence is stronger in winter than in summer for the southern part of the study area. Keywords: : Britain, dependence, sea surge, river flow, precipitation, mid-latitude cyclone, seasonality, time lag

  8. The inner mantle of the giant clam, Tridacna squamosa, expresses a basolateral Na+/K+-ATPase α-subunit, which displays light-dependent gene and protein expression along the shell-facing epithelium.

    Directory of Open Access Journals (Sweden)

    Mel V Boo

    Full Text Available Na+/K+-ATPase (NKA is essential for maintaining the Na+ and K+ gradients, and supporting the secondary active transport of certain ions/molecules, across the plasma membrane of animal cells. This study aimed to clone the NKA α-subunit (NKAα from the inner mantle adjacent to the extrapallial fluid of Tridacna squamosa, to determine its subcellular localization, and to examine the effects of light exposure on its transcript level and protein abundance. The cDNA coding sequence of NKAα from T. squamosa comprised 3105 bp, encoding 1034 amino acids with an estimated molecular mass of 114 kDa. NKAα had a basolateral localization along the shell-facing epithelium of the inner mantle. Exposure to 12 h of light led to a significantly stronger basolateral NKAα-immunofluorescence at the shell-facing epithelium, indicating that NKA might play a role in light-enhanced calcification in T. squamosa. After 3 h of light exposure, the transcript level of NKAα decreased transiently in the inner mantle, but returned to the control level thereafter. In comparison, the protein abundance of NKAα remained unchanged at hour 3, but became significantly higher than the control after 12 h of light exposure. Hence, the expression of NKAα in the inner mantle of T. squamosa was light-dependent. It is probable that a higher expression level of NKA was needed in the shell-facing epithelial cells of the inner mantle to cope with a rise in Na+ influx, possibly caused by increases in activities of some Na+-dependent ion transporters/channels involved in light-enhanced calcification.

  9. Function-oriented display system: background and first prototypes

    International Nuclear Information System (INIS)

    Andresen, Gisle; Friberg, Maarten; Teigen, Arild; Pirus, Dominique

    2004-04-01

    The objective of the function-oriented displays and alarm project is to design, implement and evaluate Human System Interfaces (HSI) based on a function-oriented design philosophy. Function-oriented design is an approach for designing HSIs where the plant's functions, identified through a function analysis, are used for determining the content, organisation, and management of displays. The project has used the 'FITNESS approach', originally developed by EDF in France, as a starting point. FITNESS provides an integrated display system consisting of process operating displays, operating procedures, alarms and trend displays - all based on a functional decomposition of the plant. So far, two prototypes have been implemented on the FRESH PWR simulator in HAMMLAB. The first prototype focused on the condensate pumps. Three process operating displays representing functions at different levels of the functional hierarchy were implemented. Computerised startup and shutdown procedures for the condensate pumps function were also implemented. In the second prototype, the scope was increased to cover the main feedwater system. The displays of the first prototype were redesigned and additional displays were created. In conclusion, the first phase of the project has been completed successfully, and we are now ready to enter the second phase. In the second phase, the scope of the prototype will be increased further to include the steam-generators and function-oriented disturbance operating procedures. The prototype will be evaluated in a user test conducted later in 2004. (Author)

  10. Reflective and transflective liquid crystal displays

    Science.gov (United States)

    Zhou, Fushan

    Recently transflective liquid crystal displays (LCD) received a lot of attention. A transflective display has a transmissive mode and a reflective mode. It combines the high contrast, high brightness of the transmissive mode with energy-saving of reflective mode and has good performance in various illumination conditions. However, state-of-the-art transflective displays have problems such as different electro-optical properties, difficulty in compatibility and optimization of both modes, low efficiency of light utilization, and complexity in structure. This dissertation focuses on finding new designs of transflective displays that address those problems. One way to do this is to study film compensation of LCD. We first studied film compensation of bistable twisted nematic (BTN) LCD. Starting form the reduced (3x3) Mueller matrices, we derived and simplified the conditions that film compensated BTN can be optimized. Based on these relations, electro-optical properties of some particular configurations, and designs of transflective BTN with high brightness and contrast were given. To confirm and get a better understanding of the results, we use the Poincare sphere to analyze film compensated BTN. The key to this approach is the existence of "fixed points". Compared with the matrix approach, this approach is more simple, elegant, and efficient. We then generalized the Poincare sphere approach to a universal approach of LCD. We applied the universal approach to film compensation of ECB and IPS, and the design of achromatic birefringent filters. We also give two more new designs of transflective displays. In the first design, a dichroic mirror is used to split the visible spectrum into two parts used in transmissive and reflective modes, respectively. Both modes can be optimized. It has a simple structure and good light utilization. A design for a full-color transflective display with good performance is also given. In the second design, each pixel is divided into two

  11. A kinesthetic-tactual display for stall deterrence

    Science.gov (United States)

    Gilson, R. D.; Ventola, R. W.; Fenton, R. E.

    1975-01-01

    A kinesthetic tactual display may be effectively used as a control aid per previous flight tests. Angle of attack information would be continuously presented to a pilot, via this display, during critical operational phases where stalls are probable. A two phase plan for evaluating this concept is presented. A first development phase would encompass: (1) display fabrication for a conventional control yoke; (2) its installation, together with other necessary instrumentation, in an experimental aircraft; and (3) preliminary flight testing by experienced pilots.

  12. Illuminant-adaptive color reproduction for mobile display

    Science.gov (United States)

    Kim, Jong-Man; Park, Kee-Hyon; Kwon, Oh-Seol; Cho, Yang-Ho; Ha, Yeong-Ho

    2006-01-01

    This paper proposes an illuminant-adaptive reproduction method using light adaptation and flare conditions for a mobile display. Mobile displays, such as PDAs and cellular phones, are viewed under various lighting conditions. In particular, images displayed in daylight are perceived as quite dark due to the light adaptation of the human visual system, as the luminance of a mobile display is considerably lower than that of an outdoor environment. In addition, flare phenomena decrease the color gamut of a mobile display by increasing the luminance of dark areas and de-saturating the chroma. Therefore, this paper presents an enhancement method composed of lightness enhancement and chroma compensation. First, the ambient light intensity is measured using a lux-sensor, then the flare is calculated based on the reflection ratio of the display device and the ambient light intensity. The relative cone response is nonlinear to the input luminance. This is also changed by the ambient light intensity. Thus, to improve the perceived image, the displayed luminance is enhanced by lightness linearization. In this paper, the image's luminance is transformed by linearization of the response to the input luminance according to the ambient light intensity. Next, the displayed image is compensated according to the physically reduced chroma, resulting from flare phenomena. The reduced chroma value is calculated according to the flare for each intensity. The chroma compensation method to maintain the original image's chroma is applied differently for each hue plane, as the flare affects each hue plane differently. At this time, the enhanced chroma also considers the gamut boundary. Based on experimental observations, the outer luminance-intensity generally ranges from 1,000 lux to 30,000 lux. Thus, in the case of an outdoor environment, i.e. greater than 1,000 lux, this study presents a color reproduction method based on an inverse cone response curve and flare condition. Consequently

  13. Assessment of display performance for medical imaging systems: Executive summary of AAPM TG18 report

    International Nuclear Information System (INIS)

    Samei, Ehsan; Badano, Aldo; Chakraborty, Dev

    2005-01-01

    Digital imaging provides an effective means to electronically acquire, archive, distribute, and view medical images. Medical imaging display stations are an integral part of these operations. Therefore, it is vitally important to assure that electronic display devices do not compromise image quality and ultimately patient care. The AAPM Task Group 18 (TG18) recently published guidelines and acceptance criteria for acceptance testing and quality control of medical display devices. This paper is an executive summary of the TG18 report. TG18 guidelines include visual, quantitative, and advanced testing methodologies for primary and secondary class display devices. The characteristics, tested in conjunction with specially designed test patterns (i.e., TG18 patterns), include reflection, geometric distortion, luminance, the spatial and angular dependencies of luminance, resolution, noise, glare, chromaticity, and display artifacts. Geometric distortions are evaluated by linear measurements of the TG18-QC test pattern, which should render distortion coefficients less than 2%/5% for primary/secondary displays, respectively. Reflection measurements include specular and diffuse reflection coefficients from which the maximum allowable ambient lighting is determined such that contrast degradation due to display reflection remains below a 20% limit and the level of ambient luminance (L amb ) does not unduly compromise luminance ratio (LR) and contrast at low luminance levels. Luminance evaluation relies on visual assessment of low contrast features in the TG18-CT and TG18-MP test patterns, or quantitative measurements at 18 distinct luminance levels of the TG18-LN test patterns. The major acceptable criteria for primary/secondary displays are maximum luminance of greater than 170/100 cd/m 2 , LR of greater than 250/100, and contrast conformance to that of the grayscale standard display function (GSDF) of better than 10%/20%, respectively. The angular response is tested to

  14. Improvements in or relating to information display arrangements

    International Nuclear Information System (INIS)

    Blay, A.G.

    1975-01-01

    An information display arrangement for use in biomedical radiography with either X- or γ-radiation or ultrasonic waves is described. This invention overcomes the drawbacks of conventional three-dimensional displays where certain features may be partially or completely obscured from view by matter which is not of interest. This improvement is achieved by interactive means using a light pen on a cathode ray tube display to effectively draw boundaries between relevant and irrelevant features. The computerised display is then up-dated from the information store containing the transmission data. (U.K.)

  15. Visual Attention to Radar Displays

    Science.gov (United States)

    Moray, N.; Richards, M.; Brophy, C.

    1984-01-01

    A model is described which predicts the allocation of attention to the features of a radar display. It uses the growth of uncertainty and the probability of near collision to call the eye to a feature of the display. The main source of uncertainty is forgetting following a fixation, which is modelled as a two dimensional diffusion process. The model was used to predict information overload in intercept controllers, and preliminary validation obtained by recording eye movements of intercept controllers in simulated and live (practice) interception.

  16. Whole-brain functional connectivity during acquisition of novel grammar: Distinct functional networks depend on language learning abilities.

    Science.gov (United States)

    Kepinska, Olga; de Rover, Mischa; Caspers, Johanneke; Schiller, Niels O

    2017-03-01

    In an effort to advance the understanding of brain function and organisation accompanying second language learning, we investigate the neural substrates of novel grammar learning in a group of healthy adults, consisting of participants with high and average language analytical abilities (LAA). By means of an Independent Components Analysis, a data-driven approach to functional connectivity of the brain, the fMRI data collected during a grammar-learning task were decomposed into maps representing separate cognitive processes. These included the default mode, task-positive, working memory, visual, cerebellar and emotional networks. We further tested for differences within the components, representing individual differences between the High and Average LAA learners. We found high analytical abilities to be coupled with stronger contributions to the task-positive network from areas adjacent to bilateral Broca's region, stronger connectivity within the working memory network and within the emotional network. Average LAA participants displayed stronger engagement within the task-positive network from areas adjacent to the right-hemisphere homologue of Broca's region and typical to lower level processing (visual word recognition), and increased connectivity within the default mode network. The significance of each of the identified networks for the grammar learning process is presented next to a discussion on the established markers of inter-individual learners' differences. We conclude that in terms of functional connectivity, the engagement of brain's networks during grammar acquisition is coupled with one's language learning abilities. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Which global stock indices trigger stronger contagion risk in the Vietnamese stock market? Evidence using a bivariate analysis

    Directory of Open Access Journals (Sweden)

    Wang Kuan-Min

    2013-01-01

    Full Text Available This paper extends recent investigations into risk contagion effects on stock markets to the Vietnamese stock market. Daily data spanning October 9, 2006 to May 3, 2012 are sourced to empirically validate the contagion effects between stock markets in Vietnam, and China, Japan, Singapore, and the US. To facilitate the validation of contagion effects with market-related coefficients, this paper constructs a bivariate EGARCH model of dynamic conditional correlation coefficients. Using the correlation contagion test and Dungey et al.’s (2005 contagion test, we find contagion effects between the Vietnamese and four other stock markets, namely Japan, Singapore, China, and the US. Second, we show that the Japanese stock market causes stronger contagion risk in the Vietnamese stock market compared to the stock markets of China, Singapore, and the US. Finally, we show that the Chinese and US stock markets cause weaker contagion effects in the Vietnamese stock market because of stronger interdependence effects between the former two markets.

  18. General multiplex centralized fire-alarm display system

    International Nuclear Information System (INIS)

    Zhu Liqun; Chen Jinming

    2002-01-01

    The fire-alarm display system is developed, which can connect with each type of fire controllers produced in the factory and SIGMASYS controllers. It can display whole alarm information. The display system software gathers communication, database and multimedia, has functions of inspecting fire, showing alarm, storing data, searching information and so on. The drawing software lets the user expediently add, delete, move and modify fire detection or fire fighting facilities on the building floor maps. The graphic transform software lets the display use the vectorgraph produced by popular plotting software such as Auto CAD. The system software provides the administration function, such as log book of changing shift and managing workers etc.. The software executed on Windows 98 platform. The user interface is friendly and reliable in operation

  19. Third-Generation Display Technology: Nominally Transparent Material

    Directory of Open Access Journals (Sweden)

    Charles Willow

    2010-12-01

    Full Text Available Display technology is reshaping the consumer, business, government, and even not-for-profit markets in the midst of the digital convergence, coupled with recent smart phones led by Apple, Inc. First-Generation (1G display technology was dominated by the Cathode Ray Tubes, followed by Liquid Crystal Display and Plasma in 2G. A radically innovative shift as a disruptive technology is expected to follow in 3G to utilize virtually any transparent material, which wirelessly connects to portable access points. This paper studies the feasibility of the 3G Display Technology (DT with Technology S-Curves, and presents possible business models and technology strategies which may be generated from it. Additional subsets of business models may be derived for a wide range of industry applications.

  20. Beyond passivity: Dependency as a risk factor for intimate partner violence.

    Science.gov (United States)

    Kane, Fallon A; Bornstein, Robert F

    2016-02-01

    Interpersonal dependency in male perpetrators of intimate partner violence (IPV) is an understudied phenomenon but one that has noteworthy clinical implications. The present investigation used meta-analytic techniques to quantify the dependency-IPV link in all extant studies examining this relationship (n of studies = 17). Studies were gathered via an extensive literature search using relevant dependency/IPV search terms in the PsychInfo, Medline and Google Scholar databases. Results revealed a small but statistically significant relationship between dependency and perpetration of IPV in men (r = 0.150, Combined Z = 4.25, p dependency-IPV link becoming stronger (r = 0.365, Combined Z = 6.00, p dependent personality disorder symptoms were omitted. Other moderators of the dependency-IPV effect size included IPV measure, type of sample and perpetrator age. These findings illuminate the underlying dynamics and interpersonal processes involved in some instances of IPV and may aid in understanding how to identify and treat male perpetrators of domestic violence. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Obstacle Detection Display for Visually Impaired: Coding of Direction, Distance, and Height on a Vibrotactile Waist Band

    Directory of Open Access Journals (Sweden)

    Jan B. F. van Erp

    2017-10-01

    Full Text Available Electronic travel aids (ETAs can potentially increase the safety and comfort of blind users by detecting and displaying obstacles outside the range of the white cane. In a series of experiments, we aim to balance the amount of information displayed and the comprehensibility of the information taking into account the risk of information overload. In Experiment 1, we investigate perception of compound signals displayed on a tactile vest while walking. The results confirm that the threat of information overload is clear and present. Tactile coding parameters that are sufficiently discriminable in isolation may not be so in compound signals and while walking and using the white cane. Horizontal tactor location is a strong coding parameter, and temporal pattern is the preferred secondary coding parameter. Vertical location is also possible as coding parameter but it requires additional tactors and makes the display hardware more complex and expensive and less user friendly. In Experiment 2, we investigate how we can off-load the tactile modality by mitigating part of the information to an auditory display. Off-loading the tactile modality through auditory presentation is possible, but this off-loading is limited and may result in a new threat of auditory overload. In addition, taxing the auditory channel may in turn interfere with other auditory cues from the environment. In Experiment 3, we off-load the tactile sense by reducing the amount of displayed information using several filter rules. The resulting design was evaluated in Experiment 4 with visually impaired users. Although they acknowledge the potential of the display, the added of the ETA as a whole also depends on its sensor and object recognition capabilities. We recommend to use not more than two coding parameters in a tactile compound message and apply filter rules to reduce the amount of obstacles to be displayed in an obstacle avoidance ETA.

  2. Pairmate-dependent pup retrieval as parental behavior in male mice

    Directory of Open Access Journals (Sweden)

    Mingkun eLiang

    2014-07-01

    Full Text Available Appropriate parental care by fathers can greatly facilitate healthy human family life. However, much less is known about paternal behavior in animals compared to those regarding maternal behavior. Previously, we reported that male ICR strain laboratory mice, although not spontaneously parental, can be induced to display maternal-like parental care (pup retrieval when separated from their pups by signals from the pairmate dam (Liu et al., Nat. Commun, 4:1346, 2013. This parental behavior by the ICR sires, which are not genetically biparental, is novel and has been designated as pairmate-dependent paternal behavior. However, the factors critical for this paternal behavior are unclear. Here, we report that the pairmate-dependent paternal retrieval behavior is observed especially in the ICR strain and not in C57BL/6 or BALB/c mice. An ICR sire displays retrieval behavior only toward his biological pups. A sire co-housed with an unrelated non-pairing dam in a new environment, under which 38-kHz ultrasonic vocalizations are not detected, does not show parenting behavior. It is important for sires to establish their own home territory (cage by continuous housing and testing to display retrieval behavior. These results indicated that the ICR sires display distinct paternity, including father-child social interaction, and shed light on parental behavior, although further analyses of paternal care at the neuroendocrinological and neurocircuitry levels are required.

  3. Head Worn Display System for Equivalent Visual Operations

    Science.gov (United States)

    Cupero, Frank; Valimont, Brian; Wise, John; Best. Carl; DeMers, Bob

    2009-01-01

    Head-Worn Displays or so-called, near-to-eye displays have potentially significant advantages in terms of cost, overcoming cockpit space constraints, and for the display of spatially-integrated information. However, many technical issues need to be overcome before these technologies can be successfully introduced into commercial aircraft cockpits. The results of three activities are reported. First, the near-to-eye display design, technological, and human factors issues are described and a literature review is presented. Second, the results of a fixed-base piloted simulation, investigating the impact of near to eye displays on both operational and visual performance is reported. Straight-in approaches were flown in simulated visual and instrument conditions while using either a biocular or a monocular display placed on either the dominant or non-dominant eye. The pilot's flight performance, visual acuity, and ability to detect unsafe conditions on the runway were tested. The data generally supports a monocular design with minimal impact due to eye dominance. Finally, a method for head tracker system latency measurement is developed and used to compare two different devices.

  4. Scream-embrace displays in wild black-horned capuchin monkeys.

    Science.gov (United States)

    Lynch Alfaro, Jessica

    2008-06-01

    Reintroduction of capuchin monkeys (Cebus apella) into their social group in captivity can elicit sirena screams and embraces. Captive scream-embrace displays are male biased, and females never perform sirena screams. One hypothesis is that scream-embrace displays serve a tension-reduction or reconciliatory function between males with conflicting interests. Alternatively, these displays may function to maintain strong affiliative bonds between friendly male dyads. Scream and/or embrace displays in wild Brazilian black-horned capuchins were analyzed for social and ecological contexts, behavioral components, and individuals involved. Seventy-two displays were observed during the 199-day study period. Among the 66 displays for which both members could be identified by sex, there were 42 occurrences of male-male dyads, 17 of male-female dyads, and seven of female-female dyads. Scream-embrace dyads were male-male pairs significantly more often than expected from group membership, and the alpha male was the only male to engage in scream-embrace displays with females. Female-female pairs did embrace, but never emitted sirena screams. Displays most commonly occurred in "reunion" contexts, primarily the reuniting of subgroups after hours or days out of contact, but also after intergroup encounters, and across groups in "intergroup" displays. Displays were rare, but socially contagious, and subgroup reunions could elicit multiple displays in rapid succession. Although the occurrence of screams and embraces was positively correlated, both behaviors also occurred independently, and their functions may be different. Male sirena screams may be honest advertisements of united alliances, directed toward a third party, whereas the embrace may be a risky affiliative signal, directed primarily within the dyad. Copyright 2008 Wiley-Liss, Inc.

  5. An Evaluation of Detect and Avoid (DAA) Displays for Unmanned Aircraft Systems: The Effect of Information Level and Display Location on Pilot Performance

    Science.gov (United States)

    Fern, Lisa; Rorie, R. Conrad; Pack, Jessica S.; Shively, R. Jay; Draper, Mark H.

    2015-01-01

    A consortium of government, industry and academia is currently working to establish minimum operational performance standards for Detect and Avoid (DAA) and Control and Communications (C2) systems in order to enable broader integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS). One subset of these performance standards will need to address the DAA display requirements that support an acceptable level of pilot performance. From a pilot's perspective, the DAA task is the maintenance of self separation and collision avoidance from other aircraft, utilizing the available information and controls within the Ground Control Station (GCS), including the DAA display. The pilot-in-the-loop DAA task requires the pilot to carry out three major functions: 1) detect a potential threat, 2) determine an appropriate resolution maneuver, and 3) execute that resolution maneuver via the GCS control and navigation interface(s). The purpose of the present study was to examine two main questions with respect to DAA display considerations that could impact pilots' ability to maintain well clear from other aircraft. First, what is the effect of a minimum (or basic) information display compared to an advanced information display on pilot performance? Second, what is the effect of display location on UAS pilot performance? Two levels of information level (basic, advanced) were compared across two levels of display location (standalone, integrated), for a total of four displays. The authors propose an eight-stage pilot-DAA interaction timeline from which several pilot response time metrics can be extracted. These metrics were compared across the four display conditions. The results indicate that the advanced displays had faster overall response times compared to the basic displays, however, there were no significant differences between the standalone and integrated displays. Implications of the findings on understanding pilot performance on the DAA task, the

  6. Temperature dependence of mode conversion in warm, unmagnetized plasmas with a linear density profile

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Dae Jung; Lee, Dong-Hun [School of Space Research, Kyung Hee University, Yongin (Korea, Republic of); Kim, Kihong [Division of Energy Systems Research, Ajou University, Suwon (Korea, Republic of)

    2013-06-15

    We study theoretically the linear mode conversion between electromagnetic waves and Langmuir waves in warm, stratified, and unmagnetized plasmas, using a numerically precise calculation based on the invariant imbedding method. We verify that the principle of reciprocity for the forward and backward mode conversion coefficients holds precisely regardless of temperature. We also find that the temperature dependence of the mode conversion coefficient is substantially stronger than that previously reported. Depending on the wave frequency and the incident angle, the mode conversion coefficient is found to increase or decrease with the increase of temperature.

  7. Drag and drop display & builder

    Energy Technology Data Exchange (ETDEWEB)

    Bolshakov, Timofei B.; Petrov, Andrey D.; /Fermilab

    2007-12-01

    The Drag and Drop (DnD) Display & Builder is a component-oriented system that allows users to create visual representations of data received from data acquisition systems. It is an upgrade of a Synoptic Display mechanism used at Fermilab since 2002. Components can be graphically arranged and logically interconnected in the web-startable Project Builder. Projects can be either lightweight AJAX- and SVG-based web pages, or they can be started as Java applications. The new version was initiated as a response to discussions between the LHC Controls Group and Fermilab.

  8. Attentional bias and executive control in treatment-seeking substance-dependent adolescents: A cross-sectional and follow-up study.

    Science.gov (United States)

    van Hemel-Ruiter, Madelon E; Wiers, Reinout W; Brook, Frank G; de Jong, Peter J

    2016-02-01

    Research in adults shows that substance dependent individuals demonstrate attentional bias (AB) for substance-related stimuli. This study investigated the role of AB in adolescents diagnosed with alcohol, cannabis, amphetamine or GHB dependency on entering therapy and six months later, and the role of executive control (EC) as a moderator of the relationship between problem severity and AB. Seventy-eight young substance-dependent (SD) patients (mean age=19.5), and 64 healthy controls (HC; mean age=19.0) were tested. Thirty-eight SD patients took part at 6-month follow-up (FU). AB was indexed by a visual probe task, EC by the attention network task, problem severity by the short alcohol (or drug) use disorder identification test and the severity of dependence questionnaire. SD patients demonstrated an AB for substance stimuli presented for 500 ms and 1250 ms, with the latter related to severity of dependence. There was a nonsignificant tendency indicating that EC was higher in HC than SD participants, but EC did not moderate the relationship between AB and dependency. Substance use, dependency, EC and AB remained unchanged in the 6 month FU period. Young SD patients showed a stronger relatively early as well as maintained AB toward substance cues. A stronger maintained attention was related to higher severity of dependence. Further, there were some indications that EC might play a role in adolescent substance use. The finding that at FU AB and problem severity were not decreased, and EC was not increased underlines the persistent character of addiction. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Time-dependent Hartree-Fock dynamics and phase transition in Lipkin-Meshkov-Glick model

    International Nuclear Information System (INIS)

    Kan, K.; Lichtner, P.C.; Dworzecka, M.; Griffin, J.J.

    1980-01-01

    The time-dependent Hartree-Fock solutions of the two-level Lipkin-Meshkov-Glick model are studied by transforming the time-dependent Hartree-Fock equations into Hamilton's canonical form and analyzing the qualitative structure of the Hartree-Fock energy surface in the phase space. It is shown that as the interaction strength increases these time-dependent Hartree-Fock solutions undergo a qualitative change associated with the ground state phase transition previously studied in terms of coherent states. For two-body interactions stronger than the critical value, two types of time-dependent Hartree-Fock solutions (the ''librations'' and ''rotations'' in Hamilton's mechanics) exist simultaneously, while for weaker interactions only the rotations persist. It is also shown that the coherent states with the maximum total pseudospin value are determinants, so that time-dependent Hartree-Fock analysis is equivalent to the coherent state method

  10. Dependence of the transference of a reduced eye on frequency of light*

    Directory of Open Access Journals (Sweden)

    T. Evans

    2011-12-01

    Full Text Available In Gaussian optics the transference is a matrix that is a complete representation of the effects of the system on a ray traversing it. Almost all of the familiar optical properties of the system, such asrefractive error and power of the system, can be calculated from the transference. Because of the central importance of the transference it is useful to have some idea of how it depends on the frequencyof light. This paper examines the simplest model eye, the reduced eye. The dependence of the transference is calculated in terms of both frequency andwavelength of light and both dependencies are displayed graphically. The principal matrix logarithms are also calculated and displayed graphically. Chromatic difference in refractive compensation, power and ametropia are obtained for the reduced eye from the transferences.  (S Afr Optom 2011 70(4 149-155

  11. Recent progress in OLED and flexible displays and their potential for application to aerospace and military display systems

    Science.gov (United States)

    Sarma, Kalluri

    2015-05-01

    Organic light emitting diode (OLED) display technology has advanced significantly in recent years and it is increasingly being adapted in consumer electronics products with premium performance, such as high resolution smart phones, Tablet PCs and TVs. Even flexible OLED displays are beginning to be commercialized in consumer electronic devices such as smart phones and smart watches. In addition to the advances in OLED emitters, successful development and adoption of OLED displays for premium performance applications relies on the advances in several enabling technologies including TFT backplanes, pixel drive electronics, pixel patterning technologies, encapsulation technologies and system level engineering. In this paper we will discuss the impact of the recent advances in LTPS and AOS TFTs, R, G, B and White OLED with color filter pixel architectures, and encapsulation, on the success of the OLEDs in consumer electronic devices. We will then discuss potential of these advances in addressing the requirements of OLED and flexible displays for the military and avionics applications.

  12. Local fluctuations of the signed traded volumes and the dependencies of demands: a copula analysis

    Science.gov (United States)

    Wang, Shanshan; Guhr, Thomas

    2018-03-01

    We investigate how the local fluctuations of the signed traded volumes affect the dependence of demands between stocks. We analyze the empirical dependence of demands using copulas and show that they are well described by a bivariate K copula density function. We find that large local fluctuations strongly increase the positive dependence but lower slightly the negative one in the copula density. This interesting feature is due to cross-correlations of volume imbalances between stocks. Also, we explore the asymmetries of tail dependencies of the copula density, which are moderate for the negative dependencies but strong for the positive ones. For the latter, we reveal that large local fluctuations of the signed traded volumes trigger stronger dependencies of demands than of supplies, probably indicating a bull market with persistent raising of prices.

  13. An algorithm for generating data accessibility recommendations for flight deck Automatic Dependent Surveillance-Broadcast (ADS-B) applications

    Science.gov (United States)

    2014-09-09

    Automatic Dependent Surveillance-Broadcast (ADS-B) In technology supports the display of traffic data on Cockpit Displays of Traffic Information (CDTIs). The data are used by flightcrews to perform defined self-separation procedures, such as the in-t...

  14. Stronger activation of SREBP-1a by nucleus-localized HBx

    International Nuclear Information System (INIS)

    Wu, Qi; Qiao, Ling; Yang, Jian; Zhou, Yan; Liu, Qiang

    2015-01-01

    We previously showed that hepatitis B virus (HBV) X protein activates the sterol regulatory element-binding protein-1a (SREBP-1a). Here we examined the role of nuclear localization of HBx in this process. In comparison to the wild-type and cytoplasmic HBx, nuclear HBx had stronger effects on SREBP-1a and fatty acid synthase transcription activation, intracellular lipid accumulation and cell proliferation. Furthermore, nuclear HBx could activate HBV enhancer I/X promoter and was more effective on up-regulating HBV mRNA level in the context of HBV replication than the wild-type HBx, while the cytoplasmic HBx had no effect. Our results demonstrate the functional significance of the nucleus-localized HBx in regulating host lipogenic pathway and HBV replication. - Highlights: • Nuclear HBx is more effective on activating SREBP-1a and FASN transcription. • Nuclear HBx is more effective on enhancing intracellular lipid accumulation. • Nuclear HBx is more effective on enhancing cell proliferation. • Nuclear HBx up-regulates HBV enhancer I/X promoter activity. • Nuclear HBx increases HBV mRNA level in the context of HBV replication

  15. Conservatives Anticipate and Experience Stronger Emotional Reactions to Negative Outcomes.

    Science.gov (United States)

    Joel, Samantha; Burton, Caitlin M; Plaks, Jason E

    2014-02-01

    The present work examined whether conservatives and liberals differ in their anticipation of their own emotional reactions to negative events. In two studies, participants imagined experiencing positive or negative outcomes in domains that do not directly concern politics. In Study 1, 190 American participants recruited online (64 male, Mage  = 32 years) anticipated their emotional responses to romantic relationship outcomes. In Study 2, 97 Canadian undergraduate students (26 male, Mage  = 21 years) reported on their anticipated and experienced emotional responses to academic outcomes. In both studies, more conservative participants predicted they would feel stronger negative emotions following negative outcomes than did more liberal participants. Furthermore, a longitudinal follow-up of Study 2 participants revealed that more conservative participants actually felt worse than more liberal participants after receiving a lower-than-desired exam grade. These effects remained even when controlling for the Big Five traits, prevention focus, and attachment style (Study 1), and optimism (Study 2). We discuss how the relationship between political orientation and anticipated affect likely contributes to differences between conservatives and liberals in styles of decision and policy choices. © 2013 Wiley Periodicals, Inc.

  16. Stronger activation of SREBP-1a by nucleus-localized HBx

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Qi [VIDO-InterVac, Veterinary Microbiology, University of Saskatchewan, Saskatoon (Canada); Qiao, Ling [VIDO-InterVac, University of Saskatchewan, Saskatoon, Saskatchewan (Canada); Yang, Jian [Drug Discovery Group, University of Saskatchewan, Saskatoon, Saskatchewan (Canada); Zhou, Yan [VIDO-InterVac, Veterinary Microbiology, Vaccinology and Immunotherapeutics, University of Saskatchewan, Saskatoon, Saskatchewan (Canada); Liu, Qiang, E-mail: qiang.liu@usask.ca [VIDO-InterVac, Veterinary Microbiology, Vaccinology and Immunotherapeutics, University of Saskatchewan, Saskatoon, Saskatchewan (Canada)

    2015-05-08

    We previously showed that hepatitis B virus (HBV) X protein activates the sterol regulatory element-binding protein-1a (SREBP-1a). Here we examined the role of nuclear localization of HBx in this process. In comparison to the wild-type and cytoplasmic HBx, nuclear HBx had stronger effects on SREBP-1a and fatty acid synthase transcription activation, intracellular lipid accumulation and cell proliferation. Furthermore, nuclear HBx could activate HBV enhancer I/X promoter and was more effective on up-regulating HBV mRNA level in the context of HBV replication than the wild-type HBx, while the cytoplasmic HBx had no effect. Our results demonstrate the functional significance of the nucleus-localized HBx in regulating host lipogenic pathway and HBV replication. - Highlights: • Nuclear HBx is more effective on activating SREBP-1a and FASN transcription. • Nuclear HBx is more effective on enhancing intracellular lipid accumulation. • Nuclear HBx is more effective on enhancing cell proliferation. • Nuclear HBx up-regulates HBV enhancer I/X promoter activity. • Nuclear HBx increases HBV mRNA level in the context of HBV replication.

  17. An integrated acquisition, display, and analysis system

    International Nuclear Information System (INIS)

    Ahmad, T.; Huckins, R.J.

    1987-01-01

    The design goal of the ND9900/Genuie was to integrate a high performance data acquisition and display subsystem with a state-of-the-art 32-bit supermicrocomputer. This was achieved by integrating a Digital Equipment Corporation MicroVAX II CPU board with acquisition and display controllers via the Q-bus. The result is a tightly coupled processing and analysis system for Pulse Height Analysis and other applications. The system architecture supports distributed processing, so that acquisition and display functions are semi-autonomous, making the VAX concurrently available for applications programs

  18. Review of defense display research programs

    Science.gov (United States)

    Tulis, Robert W.; Hopper, Darrel G.; Morton, David C.; Shashidhar, Ranganathan

    2001-09-01

    Display research has comprised a substantial portion of the defense investment in new technology for national security for the past 13 years. These investments have been made by the separate service departments and, especially, via several Defense Research Projects Agency (DARPA) programs, known collectively as the High Definition Systems (HDS) Program (which ended in 2001) and via the Office of the Secretary of Defense (OSD) Defense Production Act (DPA) Title III Program (efforts ended in 2000). Using input from the Army, Navy, and Air Force to focus research and identify insertion opportunities, DARPA and the Title III Program Office have made investments to develop the national technology base and manufacturing infrastructure necessary to meet the twin challenge of providing affordable displays in current systems and enabling the DoD strategy of winning future conflicts by getting more information to all participants during the battle. These completed DARPA and DPA research and infrastructure programs are reviewed. Service investments have been and are being made to transition display technology; examples are described. Display science and technology (S&T) visions are documented for each service to assist the identification of areas meriting consideration for future defense research.

  19. A simple device for the stereoscopic display of 3D CT images

    International Nuclear Information System (INIS)

    Haveri, M.; Suramo, I.; Laehde, S.; Karhula, V.; Junila, J.

    1997-01-01

    We describe a simple device for creating true 3D views of image pairs obtained at 3D CT reconstruction. The device presents the images in a slightly different angle of view for the left and the right eyes. This true 3D viewing technique was applied experimentally in the evaluation of complex acetabular fractures. Experiments were also made to determine the optimal angle between the images for each eye. The angle varied between 1 and 7 for different observers and also depended on the display field of view used. (orig.)

  20. 3D Display of Spacecraft Dynamics Using Real Telemetry

    Directory of Open Access Journals (Sweden)

    Sanguk Lee

    2002-12-01

    Full Text Available 3D display of spacecraft motion by using telemetry data received from satellite in real-time is described. Telemetry data are converted to the appropriate form for 3-D display by the real-time preprocessor. Stored playback telemetry data also can be processed for the display. 3D display of spacecraft motion by using real telemetry data provides intuitive comprehension of spacecraft dynamics.

  1. Children's 5-HTTLPR genotype moderates the link between maternal criticism and attentional biases specifically for facial displays of anger.

    Science.gov (United States)

    Gibb, Brandon E; Johnson, Ashley L; Benas, Jessica S; Uhrlass, Dorothy J; Knopik, Valerie S; McGeary, John E

    2011-09-01

    Theorists have proposed that negative experiences in childhood may contribute to the development of experience-specific information-processing biases, including attentional biases. There are also clear genetic influences on cognitive processes, with evidence that polymorphisms in specific candidate genes may moderate the impact of environmental stress on attentional biases (e.g., a functional polymorphism in the serotonin transporter gene; 5-HTTLPR). In the current study, we tested a gene×environment (G×E) model of risk for attentional biases. We hypothesised that children whose mothers exhibit high levels of expressed emotion criticism (EE-Crit) would display attentional biases specifically for angry, but not happy or sad, faces, and that this link would be stronger among children carrying one or two copies of the 5-HTTLPR short allele than among those homozygous for the long allele. Results generally supported these hypotheses, though we found that carriers of the 5-HTTLPR short allele who also had a critical mother exhibited attentional avoidance of angry faces rather than preferential attention.

  2. Volumetric 3D Display System with Static Screen

    Science.gov (United States)

    Geng, Jason

    2011-01-01

    Current display technology has relied on flat, 2D screens that cannot truly convey the third dimension of visual information: depth. In contrast to conventional visualization that is primarily based on 2D flat screens, the volumetric 3D display possesses a true 3D display volume, and places physically each 3D voxel in displayed 3D images at the true 3D (x,y,z) spatial position. Each voxel, analogous to a pixel in a 2D image, emits light from that position to form a real 3D image in the eyes of the viewers. Such true volumetric 3D display technology provides both physiological (accommodation, convergence, binocular disparity, and motion parallax) and psychological (image size, linear perspective, shading, brightness, etc.) depth cues to human visual systems to help in the perception of 3D objects. In a volumetric 3D display, viewers can watch the displayed 3D images from a completely 360 view without using any special eyewear. The volumetric 3D display techniques may lead to a quantum leap in information display technology and can dramatically change the ways humans interact with computers, which can lead to significant improvements in the efficiency of learning and knowledge management processes. Within a block of glass, a large amount of tiny dots of voxels are created by using a recently available machining technique called laser subsurface engraving (LSE). The LSE is able to produce tiny physical crack points (as small as 0.05 mm in diameter) at any (x,y,z) location within the cube of transparent material. The crack dots, when illuminated by a light source, scatter the light around and form visible voxels within the 3D volume. The locations of these tiny voxels are strategically determined such that each can be illuminated by a light ray from a high-resolution digital mirror device (DMD) light engine. The distribution of these voxels occupies the full display volume within the static 3D glass screen. This design eliminates any moving screen seen in previous

  3. ENERGY STAR Certified Displays

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 7.0 ENERGY STAR Program Requirements for Displays that are effective as of July 1, 2016....

  4. The Real Time Interactive Display Environment (RTIDE), a display building tool developed by Space Shuttle flight controllers

    Science.gov (United States)

    Kalvelage, Thomas A.

    1989-01-01

    NASA's Mission Control Center, located at Johnson Space Center, is incrementally moving from a centralized architecture to a distributed architecture. Starting with STS-29, some host-driven console screens will be replaced with graphics terminals driven by workstations. These workstations will be supplied realtime data first by the Real Time Data System (RTDS), a system developed inhouse, and then months later (in parallel with RTDS) by interim and subsequently operational versions of the Mission Control Center Upgrade (MCCU) software package. The Real Time Interactive Display Environment (RTIDE) was built by Space Shuttle flight controllers to support the rapid development of multiple new displays to support Shuttle flights. RTIDE is a display building tool that allows non-programmers to define object-oriented, event-driven, mouseable displays. Particular emphasis was placed on upward compatibility between RTIDE versions, ability to acquire data from different data sources, realtime performance, ability to modularly upgrade RTIDE, machine portability, and a clean, powerful user interface. The operational and organizational factors that drove RTIDE to its present form, the actual design itself, simulation and flight performance, and lessons learned in the process are discussed.

  5. Synthetic Vision System Commercial Aircraft Flight Deck Display Technologies for Unusual Attitude Recovery

    Science.gov (United States)

    Prinzel, Lawrence J., III; Ellis, Kyle E.; Arthur, Jarvis J.; Nicholas, Stephanie N.; Kiggins, Daniel

    2017-01-01

    A Commercial Aviation Safety Team (CAST) study of 18 worldwide loss-of-control accidents and incidents determined that the lack of external visual references was associated with a flight crew's loss of attitude awareness or energy state awareness in 17 of these events. Therefore, CAST recommended development and implementation of virtual day-Visual Meteorological Condition (VMC) display systems, such as synthetic vision systems, which can promote flight crew attitude awareness similar to a day-VMC environment. This paper describes the results of a high-fidelity, large transport aircraft simulation experiment that evaluated virtual day-VMC displays and a "background attitude indicator" concept as an aid to pilots in recovery from unusual attitudes. Twelve commercial airline pilots performed multiple unusual attitude recoveries and both quantitative and qualitative dependent measures were collected. Experimental results and future research directions under this CAST initiative and the NASA "Technologies for Airplane State Awareness" research project are described.

  6. Advanced Plasmonic Materials for Dynamic Color Display.

    Science.gov (United States)

    Shao, Lei; Zhuo, Xiaolu; Wang, Jianfang

    2018-04-01

    Plasmonic structures exhibit promising applications in high-resolution and durable color generation. Research on advanced hybrid plasmonic materials that allow dynamically reconfigurable color control has developed rapidly in recent years. Some of these results may give rise to practically applicable reflective displays in living colors with high performance and low power consumption. They will attract broad interest from display markets, compared with static plasmonic color printing, for example, in applications such as digital signage, full-color electronic paper, and electronic device screens. In this progress report, the most promising recent examples of utilizing advanced plasmonic materials for the realization of dynamic color display are highlighted and put into perspective. The performances, advantages, and disadvantages of different technologies are discussed, with emphasis placed on both the potential and possible limitations of various hybrid materials for dynamic plasmonic color display. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Chemical display of pyrimidine bases flipped out by modification-dependent restriction endonucleases of MspJI and PvuRts1I families.

    Directory of Open Access Journals (Sweden)

    Evelina Zagorskaitė

    Full Text Available The epigenetic DNA modifications 5-methylcytosine (5mC and 5-hydroxymethylcytosine (5hmC in eukaryotes are recognized either in the context of double-stranded DNA (e.g., by the methyl-CpG binding domain of MeCP2, or in the flipped-out state (e.g., by the SRA domain of UHRF1. The SRA-like domains and the base-flipping mechanism for 5(hmC recognition are also shared by the recently discovered prokaryotic modification-dependent endonucleases of the MspJI and PvuRts1I families. Since the mechanism of modified cytosine recognition by many potential eukaryotic and prokaryotic 5(hmC "readers" is still unknown, a fast solution based method for the detection of extrahelical 5(hmC would be very useful. In the present study we tested base-flipping by MspJI- and PvuRts1I-like restriction enzymes using several solution-based methods, including fluorescence measurements of the cytosine analog pyrrolocytosine and chemical modification of extrahelical pyrimidines with chloroacetaldehyde and KMnO4. We find that only KMnO4 proved an efficient probe for the positive display of flipped out pyrimidines, albeit the method required either non-physiological pH (4.3 or a substitution of the target cytosine with thymine. Our results imply that DNA recognition mechanism of 5(hmC binding proteins should be tested using a combination of all available methods, as the lack of a positive signal in some assays does not exclude the base flipping mechanism.

  8. Identifying Bacterial Immune Evasion Proteins Using Phage Display.

    Science.gov (United States)

    Fevre, Cindy; Scheepmaker, Lisette; Haas, Pieter-Jan

    2017-01-01

    Methods aimed at identification of immune evasion proteins are mainly rely on in silico prediction of sequence, structural homology to known evasion proteins or use a proteomics driven approach. Although proven successful these methods are limited by a low efficiency and or lack of functional identification. Here we describe a high-throughput genomic strategy to functionally identify bacterial immune evasion proteins using phage display technology. Genomic bacterial DNA is randomly fragmented and ligated into a phage display vector that is used to create a phage display library expressing bacterial secreted and membrane bound proteins. This library is used to select displayed bacterial secretome proteins that interact with host immune components.

  9. Human factors guidelines for large-screen displays

    International Nuclear Information System (INIS)

    Collier, Steve

    2005-09-01

    Any control-room project (including upgrades or evolutionary improvements to existing control-rooms) is well advised at the outset first to gather and update related background material for the design. This information-gathering exercise should also take into account experience from similar projects and operating experience. For these reasons, we decided to use our research, and experience in large-screen display design with several clients to update human factors guidance for large-screen displays, to take into account new ergonomics guidelines, operating experience, and work from similar projects. To write the updated guidelines, we drew on much of our experience across several departments at IFE, including research funded by the HRP programme, and experience with individual clients. Guidance here is accordingly focused mainly on recent areas of technical and human innovations in the man-machine interface. One particular area of focus was on the increasing use of large-screen display systems in modern control-rooms, and on how guidelines could be adapted and supplemented for their design. Guidance or reference to recommended sources is also given for control suite arrangement and layout, control-room layout, workstation layout, design of displays and controls, and design of the work environment, especially insofar as these ergonomic issues interact with the effectiveness of modern displays, in particular large screen displays. The work shows that there can be synergy between HRP research and bilateral activities: the one side offers a capability to develop tools and guidelines, while the other side gives an opportunity to test and refine these in practice, to the benefit of both parties. (Author)

  10. Human factors guidelines for large-screen displays

    Energy Technology Data Exchange (ETDEWEB)

    Collier, Steve

    2005-09-15

    Any control-room project (including upgrades or evolutionary improvements to existing control-rooms) is well advised at the outset first to gather and update related background material for the design. This information-gathering exercise should also take into account experience from similar projects and operating experience. For these reasons, we decided to use our research, and experience in large-screen display design with several clients to update human factors guidance for large-screen displays, to take into account new ergonomics guidelines, operating experience, and work from similar projects. To write the updated guidelines, we drew on much of our experience across several departments at IFE, including research funded by the HRP programme, and experience with individual clients. Guidance here is accordingly focused mainly on recent areas of technical and human innovations in the man-machine interface. One particular area of focus was on the increasing use of large-screen display systems in modern control-rooms, and on how guidelines could be adapted and supplemented for their design. Guidance or reference to recommended sources is also given for control suite arrangement and layout, control-room layout, workstation layout, design of displays and controls, and design of the work environment, especially insofar as these ergonomic issues interact with the effectiveness of modern displays, in particular large screen displays. The work shows that there can be synergy between HRP research and bilateral activities: the one side offers a capability to develop tools and guidelines, while the other side gives an opportunity to test and refine these in practice, to the benefit of both parties. (Author)

  11. Real-time Image Generation for Compressive Light Field Displays

    International Nuclear Information System (INIS)

    Wetzstein, G; Lanman, D; Hirsch, M; Raskar, R

    2013-01-01

    With the invention of integral imaging and parallax barriers in the beginning of the 20th century, glasses-free 3D displays have become feasible. Only today—more than a century later—glasses-free 3D displays are finally emerging in the consumer market. The technologies being employed in current-generation devices, however, are fundamentally the same as what was invented 100 years ago. With rapid advances in optical fabrication, digital processing power, and computational perception, a new generation of display technology is emerging: compressive displays exploring the co-design of optical elements and computational processing while taking particular characteristics of the human visual system into account. In this paper, we discuss real-time implementation strategies for emerging compressive light field displays. We consider displays composed of multiple stacked layers of light-attenuating or polarization-rotating layers, such as LCDs. The involved image generation requires iterative tomographic image synthesis. We demonstrate that, for the case of light field display, computed tomographic light field synthesis maps well to operations included in the standard graphics pipeline, facilitating efficient GPU-based implementations with real-time framerates.

  12. Hewlett-Packard's Approaches to Full Color Reflective Displays

    Science.gov (United States)

    Gibson, Gary

    2012-02-01

    Reflective displays are desirable in applications requiring low power or daylight readability. However, commercial reflective displays are currently either monochrome or capable of only dim color gamuts. Low cost, high-quality color technology would be rapidly adopted in existing reflective display markets and would enable new solutions in areas such as retail pricing and outdoor digital signage. Technical breakthroughs are required to enable bright color gamuts at reasonable cost. Pixel architectures that rely on pure reflection from a single layer of side-by-side primary-color sub-pixels use only a fraction of the display area to reflect incident light of a given color and are, therefore, unacceptably dark. Reflective devices employing stacked color primaries offer the possibility of a somewhat brighter color gamut but can be more complex to manufacture. In this talk, we describe HP's successes in addressing these fundamental challenges and creating both high performance stacked-primary reflective color displays as well as inexpensive single layer prototypes that provide good color. Our stacked displays utilize a combination of careful light management techniques, proprietary high-contrast electro-optic shutters, and highly transparent active-matrix TFT arrays based on transparent metal oxides. They also offer the possibility of relatively low cost manufacturing through roll-to-roll processing on plastic webs. To create even lower cost color displays with acceptable brightness, we have developed means for utilizing photoluminescence to make more efficient use of ambient light in a single layer device. Existing reflective displays create a desired color by reflecting a portion of the incident spectrum while absorbing undesired wavelengths. We have developed methods for converting the otherwise-wasted absorbed light to desired wavelengths via tailored photoluminescent composites. Here we describe a single active layer prototype display that utilizes these materials

  13. NIST display colorimeter calibration facility

    Science.gov (United States)

    Brown, Steven W.; Ohno, Yoshihiro

    2003-07-01

    A facility has been developed at the National Institute of Standards and Technology (NIST) to provide calibration services for color-measuring instruments to address the need for improving and certifying the measurement uncertainties of this type of instrument. While NIST has active programs in photometry, flat panel display metrology, and color and appearance measurements, these are the first services offered by NIST tailored to color-measuring instruments for displays. An overview of the facility, the calibration approach, and associated uncertainties are presented. Details of a new tunable colorimetric source and the development of new transfer standard instruments are discussed.

  14. 3D Image Display Courses for Information Media Students.

    Science.gov (United States)

    Yanaka, Kazuhisa; Yamanouchi, Toshiaki

    2016-01-01

    Three-dimensional displays are used extensively in movies and games. These displays are also essential in mixed reality, where virtual and real spaces overlap. Therefore, engineers and creators should be trained to master 3D display technologies. For this reason, the Department of Information Media at the Kanagawa Institute of Technology has launched two 3D image display courses specifically designed for students who aim to become information media engineers and creators.

  15. Lateralisation of aggressive displays in a tephritid fly

    Science.gov (United States)

    Benelli, Giovanni; Donati, Elisa; Romano, Donato; Stefanini, Cesare; Messing, Russell H.; Canale, Angelo

    2015-02-01

    Lateralisation (i.e. different functional and/or structural specialisations of the left and right sides of the brain) of aggression has been examined in several vertebrate species, while evidence for invertebrates is scarce. In this study, we investigated lateralisation of aggressive displays (boxing with forelegs and wing strikes) in the Mediterranean fruit fly, Ceratitis capitata. We attempted to answer the following questions: (1) do medflies show lateralisation of aggressive displays at the population-level; (2) are there sex differences in lateralisation of aggressive displays; and (3) does lateralisation of aggression enhance fighting success? Results showed left-biased population-level lateralisation of aggressive displays, with no consistent differences among sexes. In both male-male and female-female conflicts, aggressive behaviours performed with left body parts led to greater fighting success than those performed with right body parts. As we found left-biased preferential use of body parts for both wing strikes and boxing, we predicted that the left foreleg/wing is quicker in exploring/striking than the right one. We characterised wing strike and boxing using high-speed videos, calculating mean velocity of aggressive displays. For both sexes, aggressive displays that led to success were faster than unsuccessful ones. However, left wing/legs were not faster than right ones while performing aggressive acts. Further research is needed on proximate causes allowing enhanced fighting success of lateralised aggressive behaviour. This is the first report supporting the adaptive role of lateralisation of aggressive displays in insects.

  16. A green-color portable waveguide eyewear display system

    Science.gov (United States)

    Xia, Lingbo; Xu, Ke; Wu, Zhengming; Hu, Yingtian; Li, Zhenzhen; Wang, Yongtian; Liu, Juan

    2013-08-01

    Waveguide display systems are widely used in various display fields, especially in head mounted display. Comparing with the traditional head mounted display system, this device dramatically reduce the size and mass. However, there are still several fatal problems such as high scatting, the cumbersome design and chromatic aberration that should be solved. We designed and fabricated a monochromatic portable eyewear display system consist of a comfortable eyewear device and waveguide system with two holographic gratings located on the substrate symmetrically. We record the gratings on the photopolymer medium with high efficiency and wavelength sensitivity. The light emitting from the micro-display is diffracted by the grating and trapped in the glass substrate by total internal reflection. The relationship between the diffraction efficiency and exposure value is studied and analyzed, and we fabricated the gratings with appropriate diffraction efficiency in a optimization condition. To avoid the disturbance of the stray light, we optimize the waveguide system numerically and perform the optical experiments. With this system, people can both see through the waveguide to obtain the information outside and catch the information from the micro display. After considering the human body engineering and industrial production, we design the structure in a compact and portable way. It has the advantage of small-type configuration and economic acceptable. It is believe that this kind of planar waveguide system is a potentially replaceable choice for the portable devices in future mobile communications.

  17. A Qualitative Method to Estimate HSI Display Complexity

    International Nuclear Information System (INIS)

    Hugo, Jacques; Gertman, David

    2013-01-01

    There is mounting evidence that complex computer system displays in control rooms contribute to cognitive complexity and, thus, to the probability of human error. Research shows that reaction time increases and response accuracy decreases as the number of elements in the display screen increase. However, in terms of supporting the control room operator, approaches focusing on addressing display complexity solely in terms of information density and its location and patterning, will fall short of delivering a properly designed interface. This paper argues that information complexity and semantic complexity are mandatory components when considering display complexity and that the addition of these concepts assists in understanding and resolving differences between designers and the preferences and performance of operators. This paper concludes that a number of simplified methods, when combined, can be used to estimate the impact that a particular display may have on the operator's ability to perform a function accurately and effectively. We present a mixed qualitative and quantitative approach and a method for complexity estimation

  18. 14 CFR 147.39 - Display of certificate.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Display of certificate. 147.39 Section 147...) SCHOOLS AND OTHER CERTIFICATED AGENCIES AVIATION MAINTENANCE TECHNICIAN SCHOOLS Operating Rules § 147.39 Display of certificate. Each holder of an aviation maintenance technician school certificate and ratings...

  19. A ROOT based event display software for JUNO

    Science.gov (United States)

    You, Z.; Li, K.; Zhang, Y.; Zhu, J.; Lin, T.; Li, W.

    2018-02-01

    An event display software SERENA has been designed for the Jiangmen Underground Neutrino Observatory (JUNO). The software has been developed in the JUNO offline software system and is based on the ROOT display package EVE. It provides an essential tool to display detector and event data for better understanding of the processes in the detectors. The software has been widely used in JUNO detector optimization, simulation, reconstruction and physics study.

  20. Liquid Crystal Microlenses for Autostereoscopic Displays

    Directory of Open Access Journals (Sweden)

    José Francisco Algorri

    2016-01-01

    Full Text Available Three-dimensional vision has acquired great importance in the audiovisual industry in the past ten years. Despite this, the first generation of autostereoscopic displays failed to generate enough consumer excitement. Some reasons are little 3D content and performance issues. For this reason, an exponential increase in three-dimensional vision research has occurred in the last few years. In this review, a study of the historical impact of the most important technologies has been performed. This study is carried out in terms of research manuscripts per year. The results reveal that research on spatial multiplexing technique is increasing considerably and today is the most studied. For this reason, the state of the art of this technique is presented. The use of microlenses seems to be the most successful method to obtain autostereoscopic vision. When they are fabricated with liquid crystal materials, extended capabilities are produced. Among the numerous techniques for manufacturing liquid crystal microlenses, this review covers the most viable designs for its use in autostereoscopic displays. For this reason, some of the most important topologies and their relation with autostereoscopic displays are presented. Finally, the challenges in some recent applications, such as portable devices, and the future of three-dimensional displays based on liquid crystal microlenses are outlined.

  1. A wearable navigation display can improve attentiveness to the surgical field.

    Science.gov (United States)

    Stewart, James; Billinghurst, Mark

    2016-06-01

    Surgical navigation is typically shown on a computer display that is distant from the patient, making it difficult for the surgeon to watch the patient while performing a guided task. We investigate whether a light-weight, untracked, wearable display (such as Google Glass, which has the same size and weight as corrective glasses) can improve attentiveness to the surgical field in a simulated surgical task. Three displays were tested: a computer monitor; a peripheral display above the eye; and a through-the-lens display in front of the eye. Twelve subjects performed a task to position and orient a tracked tool on a plastic femur. Both wearable displays were tested on the dominant and non-dominant eyes of each subject. Attentiveness during the task was measured by the time taken to respond to randomly illuminated LEDs on the femur. Attentiveness was improved with the wearable displays at the cost of a decrease in accuracy. The through-the-lens display performed better than the peripheral display. The peripheral display performed better when on the dominant eye, while the through-the-lens display performed better when on the non-dominant eye. Attentiveness to the surgical field can be improved with the use of a light-weight, untracked, wearable display. A through-the-lens display performs better than a peripheral display, and both perform better than a computer monitor. Eye dominance should be considered when positioning the display.

  2. The q-dependent detrended cross-correlation analysis of stock market

    Science.gov (United States)

    Zhao, Longfeng; Li, Wei; Fenu, Andrea; Podobnik, Boris; Wang, Yougui; Stanley, H. Eugene

    2018-02-01

    Properties of the q-dependent cross-correlation matrices of the stock market have been analyzed by using random matrix theory and complex networks. The correlation structures of the fluctuations at different magnitudes have unique properties. The cross-correlations among small fluctuations are much stronger than those among large fluctuations. The large and small fluctuations are dominated by different groups of stocks. We use complex network representation to study these q-dependent matrices and discover some new identities. By utilizing those q-dependent correlation-based networks, we are able to construct some portfolios of those more independent stocks which consistently perform better. The optimal multifractal order for portfolio optimization is around q  =  2 under the mean-variance portfolio framework, and q\\in[2, 6] under the expected shortfall criterion. These results have deepened our understanding regarding the collective behavior of the complex financial system.

  3. Evaluation of technical design of advanced information display(III)

    International Nuclear Information System (INIS)

    Cha, Woo Chang; Jung, Sung Hae; Park, Joon Yong; Kim, Nam Cheol; Park, Soon Hyuk

    2005-02-01

    As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on visual display terminal. This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing digitalized information display by finding the generic guidelines involving information display design issues, and the relationship among the guidelines. The design issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices. The Design Review Supporting System for Advanced Information Display(DReSS-AID) was developed for the practical usage of evaluators-in-field, which was implemented with Hangul version guidelines

  4. Evaluation of technical design of advanced information display(III)

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Woo Chang; Jung, Sung Hae; Park, Joon Yong; Kim, Nam Cheol [Kumoh National Institute of Technology, Gumi (Korea, Republic of); Park, Soon Hyuk [DNT Inc., Daejeon (Korea, Republic of)

    2005-02-15

    As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on visual display terminal. This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing digitalized information display by finding the generic guidelines involving information display design issues, and the relationship among the guidelines. The design issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices. The Design Review Supporting System for Advanced Information Display(DReSS-AID) was developed for the practical usage of evaluators-in-field, which was implemented with Hangul version guidelines.

  5. Varifocal mirror display of organ surfaces from CT scans

    International Nuclear Information System (INIS)

    Pizer, S.M.; Fuchs, H.; Bloomberg, S.H.; Li Ching Tsai; Heinz, E.R.

    1982-01-01

    A means will be presented of constructing a powerful varifocal mirror 3D display system with limited cost based on an ordinary color video digital display system. The importance of dynamic interactive control of the display of these images will be discussed; in particular, the design and usefulness of a method allowing real-time user-controlled motion of the 3D object being displayed will be discussed. Also, an effective method will be described of presenting images made of surfaces by the straightforward, automatic calculation of 3D edge strength, the ordering of the resulting voxels by edge strength, and the 3D grey-scale display of the top voxels on this ordered list. The application of these ideas to the 3D display of the intimal wall of the region of bifurcation of the carotid artery from 12-24 CT scans of the neck will be discussed

  6. Effects of alcohol intake on brain structure and function in non-alcohol-dependent drinkers

    NARCIS (Netherlands)

    Bruin, Eveline Astrid de

    2005-01-01

    About 85% of the adult population in the Netherlands regularly drinks alcohol. Chronic excessive alcohol intake in alcohol-dependent individuals is known to have damaging effects on brain structure and function. Relatives of alcohol-dependent individuals display differences in brain function that

  7. Simulation of the Nonlinear Dose Dependence of Stabilized Point Defects

    International Nuclear Information System (INIS)

    Chen, R; Pagonis, V; Lawless, J L

    2010-01-01

    The dose dependence of the concentration of point defects in alkali-halides as well as other crystals, as exhibited by the dependence of the thermoluminescence (TL), optical absorption and ESR on the dose of non-ionizing UV excitation is studied using numerical simulation. The relevant set of coupled rate equations are first written and plausible sets of trapping parameters are chosen. Instead of using simplifying assumptions previously used for reaching conclusions concerning this dose behavior, exact numerical solutions have now been reached. Depending on the parameters chosen, different dose dependencies are seen. In some cases, linear dose dependence is reached in a broad range. Sublinear dose dependence, close to a D 1/2 dependence when D is the dose of excitation can be reached when retrapping is stronger than trapping in other traps stabilizing the defects. When strong competition between stabilizing traps takes place, an initial linear range is observed followed by strong superlinearity and an approach to saturation. All these behaviors have been observed experimentally in TL measurements as well as ESR and optical absorption in different materials. Similarities and dissimilarities to linear and non-linear dose dependencies obtained experimentally and by simulations when ionizing irradiation is used for excitation are discussed.

  8. A programmable display layer for virtual reality system architectures

    NARCIS (Netherlands)

    Smit, F.A.; Liere, van R.; Fröhlich, B.

    2010-01-01

    Display systems typically operate at a minimum rate of 60 Hz. However, existing VR-architectures generally produce application updates at a lower rate. Consequently, the display is not updated by the application every display frame. This causes a number of undesirable perceptual artifacts. We

  9. DUMA - a program to display distributions in hexagonal geometry

    International Nuclear Information System (INIS)

    Tran Quoc Dung; Makai, M.

    1987-09-01

    DUMA program displays hexagonal structures applied in WWER-440 reactors or one or two distributions in them. It helps users to display either integer, literal or real arrays in an arbitrary hexagonal structure. Possible applications: displaying reactor core layout, power distribution or activity measurements. (author)

  10. Image Quality Characteristics of Handheld Display Devices for Medical Imaging

    Science.gov (United States)

    Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo

    2013-01-01

    Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113

  11. Thermoluminescence emission spectrometry of glass display in mobile phones and resulting evaluation of the dosimetric properties of a specific type of display glass

    International Nuclear Information System (INIS)

    Discher, Michael; Woda, Clemens

    2014-01-01

    Glass displays of mobile phones are sensitive to ionizing radiation and can be used for retrospective dosimetry for the purpose of triage after a radiological accident or attack. In this study the two main types of glass display that are used in modern mobile phones were investigated using thermoluminescence (TL) emission spectrometry. A different TL spectrum was observed for the glass display of category A (lime-aluminosilicate glass) and category B (boron-silicate glass). Based on the spectral measurements an optimized detection window was chosen to re-evaluate the dosimetric properties (dose response, optical and long-term stability) of glass display category B. - Highlights: • Two display glass types show similar TL emission peaks but with strongly different relative intensities. • The intrinsic background TL signal peaks at similar wavelengths as the radiation induced signal. • Dosimetric properties of one display glass type were re-evaluated using an optimized detection window

  12. FORMATION AND ELECTROCHEMICAL BEHAVIOUR OF POLYION COMPLEXES FOR ELECTROCHROMIC DISPLAY MATERIAL

    Institute of Scientific and Technical Information of China (English)

    WAN Guoxiang; WANG Bing; DENG Zhenghua; LUO Chunqiao

    1988-01-01

    Formation of intermacromolecular complexes containing viologen and electron-transfer reaction occurred on the electrode modified by the complex films were studied. Compositions and morphology of the complexes depend on the properties of polyanion and chemical environment of complexation. The analytical results of cyclic voltammetry (CV) and rotating disk voltammetry(RDV) indicated: (1) active sites of viologen in network of complexes transferred single electron reversibly; (2) the redox peak currents showed excellent symmetry and stability; (3) redox potentials were related to properties of polyanions, varying from -0.4 to -0.6V (vs. SCE). Electrochromic materials with different displaying colors could be obtained by changing the structure of polyviologen.

  13. Smart TV-Smartphone Multiscreen Interactive Middleware for Public Displays.

    Science.gov (United States)

    Martinez-Pabon, Francisco; Caicedo-Guerrero, Jaime; Ibarra-Samboni, Jhon Jairo; Ramirez-Gonzalez, Gustavo; Hernández-Leo, Davinia

    2015-01-01

    A new generation of public displays demands high interactive and multiscreen features to enrich people's experience in new pervasive environments. Traditionally, research on public display interaction has involved mobile devices as the main characters during the use of personal area network technologies such as Bluetooth or NFC. However, the emergent Smart TV model arises as an interesting alternative for the implementation of a new generation of public displays. This is due to its intrinsic connection capabilities with surrounding devices like smartphones or tablets. Nonetheless, the different approaches proposed by the most important vendors are still underdeveloped to support multiscreen and interaction capabilities for modern public displays, because most of them are intended for domestic environments. This research proposes multiscreen interactive middleware for public displays, which was developed from the principles of a loosely coupled interaction model, simplicity, stability, concurrency, low latency, and the usage of open standards and technologies. Moreover, a validation prototype is proposed in one of the most interesting public display scenarios: the advertising.

  14. Latency requirements for head-worn display S/EVS applications

    Science.gov (United States)

    Bailey, Randall E.; Arthur, Jarvis J., III; Williams, Steven P.

    2004-08-01

    NASA's Aviation Safety Program, Synthetic Vision Systems Project is conducting research in advanced flight deck concepts, such as Synthetic/Enhanced Vision Systems (S/EVS), for commercial and business aircraft. An emerging thrust in this activity is the development of spatially-integrated, large field-of-regard information display systems. Head-worn or helmet-mounted display systems are being proposed as one method in which to meet this objective. System delays or latencies inherent to spatially-integrated, head-worn displays critically influence the display utility, usability, and acceptability. Research results from three different, yet similar technical areas - flight control, flight simulation, and virtual reality - are collectively assembled in this paper to create a global perspective of delay or latency effects in head-worn or helmet-mounted display systems. Consistent definitions and measurement techniques are proposed herein for universal application and latency requirements for Head-Worn Display S/EVS applications are drafted. Future research areas are defined.

  15. Looking forward: In-vehicle auxiliary display positioning affects carsickness.

    Science.gov (United States)

    Kuiper, Ouren X; Bos, Jelte E; Diels, Cyriel

    2018-04-01

    Carsickness is associated with a mismatch between actual and anticipated sensory signals. Occupants of automated vehicles, especially when using a display, are at higher risk of becoming carsick than drivers of conventional vehicles. This study aimed to evaluate the impact of positioning of in-vehicle displays, and subsequent available peripheral vision, on carsickness of passengers. We hypothesized that increased peripheral vision during display use would reduce carsickness. Seated in the front passenger seat 18 participants were driven a 15-min long slalom on two occasions while performing a continuous visual search-task. The display was positioned either at 1) eye-height in front of the windscreen, allowing peripheral view on the outside world, and 2) the height of the glove compartment, allowing only limited view on the outside world. Motion sickness was reported at 1-min intervals. Using a display at windscreen height resulted in less carsickness compared to a display at glove compartment height. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Nucleic acid secondary structure prediction and display.

    OpenAIRE

    Stüber, K

    1986-01-01

    A set of programs has been developed for the prediction and display of nucleic acid secondary structures. Information from experimental data can be used to restrict or enforce secondary structural elements. The predictions can be displayed either on normal line printers or on graphic devices like plotters or graphic terminals.

  17. Effect of display type and room illuminance in chest radiographs

    International Nuclear Information System (INIS)

    Liukkonen, Esa; Jartti, Airi; Haapea, Marianne; Oikarinen, Heljae; Ahvenjaervi, Lauri; Mattila, Seija; Nevala, Terhi; Palosaari, Kari; Perhomaa, Marja; Nieminen, Miika T.

    2016-01-01

    To compare diagnostic accuracy in the detection of subtle chest lesions on digital chest radiographs using medical-grade displays, consumer-grade displays, and tablet devices under bright and dim ambient light. Five experienced radiologists independently assessed 50 chest radiographs (32 with subtle pulmonary findings and 18 without apparent findings) under bright (510 lx) and dim (16 lx) ambient lighting. Computed tomography was used as the reference standard for interstitial and nodular lesions and follow-up chest radiograph for pneumothorax. Diagnostic accuracy and sensitivity were calculated for assessments carried out in all displays and compared using the McNemar test. The level of significance was set to p < 0.05. Significant differences in sensitivity between the assessments under bright and dim lighting were found among consumer-grade displays in interstitial opacities with, and in pneumothorax without, Digital Imaging and Communication in Medicine-Grayscale Standard Display Function (DICOM-GSDF) calibration. Compared to 6 megapixel (MP) display under bright lighting, sensitivity in pneumothorax was lower in the tablet device and the consumer-grade display. Sensitivity in interstitial opacities was lower in the DICOM-GSDF calibrated consumer-grade display. A consumer-grade display with or without DICOM-GSDF calibration or a tablet device is not suitable for reading digital chest radiographs in bright lighting. No significant differences were observed between five displays in dim light. (orig.)

  18. OZ: An Innovative Primary Flight Display, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed SBIR project will develop OZ, an innovative primary flight display for aircraft. The OZ display, designed from "first principles" of vision science,...

  19. A comparison of tracking with visual and kinesthetic-tactual displays

    Science.gov (United States)

    Jagacinski, R. J.; Flach, J. M.; Gilson, R. D.

    1981-01-01

    Recent research on manual tracking with a kinesthetic-tactual (KT) display suggests that under appropriate conditions it may be an effective means of providing visual workload relief. In order to better understand how KT tracking differs from visual tracking, both a critical tracking task and stationary single-axis tracking tasks were conducted with and without velocity quickening. On the critical tracking task, the visual displays were superior; however, the KT quickened display was approximately equal to the visual unquickened display. Mean squared error scores in the stationary tracking tasks for the visual and KT displays were approximately equal in the quickened conditions, and the describing functions were very similar. In the unquickened conditions, the visual display was superior. Subjects using the unquickened KT display exhibited a low frequency lead-lag that may be related to sensory adaptation.

  20. Arginine-dependent acid resistance in Salmonella enterica serovar Typhimurium

    NARCIS (Netherlands)

    Kieboom, J.; Abee, T.

    2006-01-01

    Salmonella enterica serovar Typhimurium does not survive a pH 2.5 acid challenge under conditions similar to those used for Escherichia coli (J. W. Foster, Nat. Rev. Microbiol. 2:898-907, 2004). Here, we provide evidence that S. enterica serovar Typhimurium can display arginine-dependent acid

  1. Cyclin-Dependent Kinase Inhibitor AT7519 as a Potential Drug for MYCN-Dependent Neuroblastoma.

    Science.gov (United States)

    Dolman, M Emmy M; Poon, Evon; Ebus, Marli E; den Hartog, Ilona J M; van Noesel, Carel J M; Jamin, Yann; Hallsworth, Albert; Robinson, Simon P; Petrie, Kevin; Sparidans, Rolf W; Kok, Robbert J; Versteeg, Rogier; Caron, Huib N; Chesler, Louis; Molenaar, Jan J

    2015-11-15

    MYCN-dependent neuroblastomas have low cure rates with current multimodal treatment regimens and novel therapeutic drugs are therefore urgently needed. In previous preclinical studies, we have shown that targeted inhibition of cyclin-dependent kinase 2 (CDK2) resulted in specific killing of MYCN-amplified neuroblastoma cells. This study describes the in vivo preclinical evaluation of the CDK inhibitor AT7519. Preclinical drug testing was performed using a panel of MYCN-amplified and MYCN single copy neuroblastoma cell lines and different MYCN-dependent mouse models of neuroblastoma. AT7519 killed MYCN-amplified neuroblastoma cell lines more potently than MYCN single copy cell lines with a median LC50 value of 1.7 compared to 8.1 μmol/L (P = 0.0053) and a significantly stronger induction of apoptosis. Preclinical studies in female NMRI homozygous (nu/nu) mice with neuroblastoma patient-derived MYCN-amplified AMC711T xenografts revealed dose-dependent growth inhibition, which correlated with intratumoral AT7519 levels. CDK2 target inhibition by AT7519 was confirmed by significant reductions in levels of phosphorylated retinoblastoma (p-Rb) and nucleophosmin (p-NPM). AT7519 treatment of Th-MYCN transgenic mice resulted in improved survival and clinically significant tumor regression (average tumor size reduction of 86% at day 7 after treatment initiation). The improved efficacy of AT7519 observed in Th-MYCN mice correlated with higher tumor exposure to the drug. This study strongly suggests that AT7519 is a promising drug for the treatment of high-risk neuroblastoma patients with MYCN amplification. ©2015 American Association for Cancer Research.

  2. A novel shape-changing haptic table-top display

    Science.gov (United States)

    Wang, Jiabin; Zhao, Lu; Liu, Yue; Wang, Yongtian; Cai, Yi

    2018-01-01

    A shape-changing table-top display with haptic feedback allows its users to perceive 3D visual and texture displays interactively. Since few existing devices are developed as accurate displays with regulatory haptic feedback, a novel attentive and immersive shape changing mechanical interface (SCMI) consisting of image processing unit and transformation unit was proposed in this paper. In order to support a precise 3D table-top display with an offset of less than 2 mm, a custommade mechanism was developed to form precise surface and regulate the feedback force. The proposed image processing unit was capable of extracting texture data from 2D picture for rendering shape-changing surface and realizing 3D modeling. The preliminary evaluation result proved the feasibility of the proposed system.

  3. [Microcomputer control of a LED stimulus display device].

    Science.gov (United States)

    Ohmoto, S; Kikuchi, T; Kumada, T

    1987-02-01

    A visual stimulus display system controlled by a microcomputer was constructed at low cost. The system consists of a LED stimulus display device, a microcomputer, two interface boards, a pointing device (a "mouse") and two kinds of software. The first software package is written in BASIC. Its functions are: to construct stimulus patterns using the mouse, to construct letter patterns (alphabet, digit, symbols and Japanese letters--kanji, hiragana, katakana), to modify the patterns, to store the patterns on a floppy disc, to translate the patterns into integer data which are used to display the patterns in the second software. The second software package, written in BASIC and machine language, controls display of a sequence of stimulus patterns in predetermined time schedules in visual experiments.

  4. Reciprocal Engagement Between a Scientist and Visual Displays

    Science.gov (United States)

    Nolasco, Michelle Maria

    In this study the focus of investigation was the reciprocal engagement between a professional scientist and the visual displays with which he interacted. Visual displays are considered inextricable from everyday scientific endeavors and their interpretation requires a "back-and-forthness" between the viewers and the objects being viewed. The query that drove this study was: How does a scientist engage with visual displays during the explanation of his understanding of extremely small biological objects? The conceptual framework was based in embodiment where the scientist's talk, gesture, and body position were observed and microanalyzed. The data consisted of open-ended interviews that positioned the scientist to interact with visual displays when he explained the structure and function of different sub-cellular features. Upon microanalyzing the scientist's talk, gesture, and body position during his interactions with two different visual displays, four themes were uncovered: Naming, Layering, Categorizing, and Scaling . Naming occurred when the scientist added markings to a pre-existing, hand-drawn visual display. The markings had meaning as stand-alone label and iconic symbols. Also, the markings transformed the pre-existing visual display, which resulted in its function as a new visual object. Layering occurred when the scientist gestured over images so that his gestures aligned with one or more of the image's features, but did not touch the actual visual display. Categorizing occurred when the scientist used contrasting categories, e.g. straight vs. not straight, to explain his understanding about different characteristics that the small biological objects held. Scaling occurred when the scientist used gesture to resize an image's features so that they fit his bodily scale. Three main points were drawn from this study. First, the scientist employed a variety of embodied strategies—coordinated talk, gesture, and body position—when he explained the structure

  5. States agree on stronger physical protection regime

    International Nuclear Information System (INIS)

    2005-01-01

    Full text: Delegates from 89 countries agreed on 8 July to fundamental changes that will substantially strengthen the Convention on the Physical Protection of Nuclear Material (CPPNM). IAEA Director General Mohamed ElBaradei welcomed the agreement in saying 'This new and stronger treaty is an important step towards greater nuclear security by combating, preventing, and ultimately punishing those who would engage in nuclear theft, sabotage or even terrorism. It demonstrates that there is indeed a global commitment to remedy weaknesses in our nuclear security regime.' The amended CPPNM makes it legally binding for States Parties to protect nuclear facilities and material in peaceful domestic use, storage as well as transport. It will also provide for expanded cooperation between and among States regarding rapid measures to locate and recover stolen or smuggled nuclear material, mitigate any radiological consequences of sabotage, and prevent and combat related offences. The original CPPNM applied only to nuclear material in international transport. Conference President Dr. Alec Baer said 'All 89 delegations demonstrated real unity of purpose. They put aside some very genuine national concerns in favour of the global interest and the result is a much improved convention that is better suited to addressing the nuclear security challenges we currently face.' The new rules will come into effect once they have been ratified by two-thirds of the 112 States Parties of the Convention, expected to take several years. 'But concrete actions are already taking place around the world. For more than 3 years, the IAEA has been implementing a systematic Nuclear Security plan, including physical protection activities designed to prevent, detect and respond to malicious acts,' said Anita Nillson, Director of the IAEA's Office of Nuclear Security. The Agency's Nuclear Security Fund, set up after the events of 9/11, has delivered $19.5 million in practical assistance to 121 countries

  6. Evaluation of technical design of advanced information display(II)

    International Nuclear Information System (INIS)

    Cha, Woo Chang; Kang, Young Ju; Ji, Jung Hun; Jang, Sung Pil; Jung, Sung Hae; Park, Hyun Jin

    2004-02-01

    As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on visual display terminal such as CRT. This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing information display on CRT by finding the generic guidelines involving information display design issues, and the relationship among the guidelines. The design issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices

  7. Evaluation of technical design of advanced information display(II)

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Woo Chang; Kang, Young Ju; Ji, Jung Hun; Jang, Sung Pil; Jung, Sung Hae; Park, Hyun Jin [Kumoh National Univ., Gumi (Korea, Republic of)

    2004-02-15

    As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on visual display terminal such as CRT. This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing information display on CRT by finding the generic guidelines involving information display design issues, and the relationship among the guidelines. The design issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices.

  8. Large Display Interaction Using Mobile Devices

    OpenAIRE

    Bauer, Jens

    2015-01-01

    Large displays become more and more popular, due to dropping prices. Their size and high resolution leverages collaboration and they are capable of dis- playing even large datasets in one view. This becomes even more interesting as the number of big data applications increases. The increased screen size and other properties of large displays pose new challenges to the Human- Computer-Interaction with these screens. This includes issues such as limited scalability to the number of users, diver...

  9. Projection display technology for avionics applications

    Science.gov (United States)

    Kalmanash, Michael H.; Tompkins, Richard D.

    2000-08-01

    Avionics displays often require custom image sources tailored to demanding program needs. Flat panel devices are attractive for cockpit installations, however recent history has shown that it is not possible to sustain a business manufacturing custom flat panels in small volume specialty runs. As the number of suppliers willing to undertake this effort shrinks, avionics programs unable to utilize commercial-off-the-shelf (COTS) flat panels are placed in serious jeopardy. Rear projection technology offers a new paradigm, enabling compact systems to be tailored to specific platform needs while using a complement of COTS components. Projection displays enable improved performance, lower cost and shorter development cycles based on inter-program commonality and the wide use of commercial components. This paper reviews the promise and challenges of projection technology and provides an overview of Kaiser Electronics' efforts in developing advanced avionics displays using this approach.

  10. The human factors of CRT displays for nuclear power plant control

    International Nuclear Information System (INIS)

    Danchak, M.M.

    1984-01-01

    This chapter attempts to show how the Cathode Ray Tube (CRT) can be used to effectively present information to the operator rather than just data. The capabilities of the human as a sensing and information processing subsystem are discussed with CRT displays in mind. The display system is described in terms of its hardware and functioning. The interface between the two is examined by providing substantive guidelines for the effective design of CRT displays for nuclear power plant control. Alphanumeric displays, graphic displays, and representational displays are treated. The design of CRT displays for nuclear power plant control requires an extensive knowledge of cognitive psychology, computer display systems and the process being controlled

  11. Experience with model based display for advanced diagnostics and control

    International Nuclear Information System (INIS)

    Staffon, J.D.; Lindsay, R.W.

    1989-01-01

    A full color, model based display system based on the Rankine thermodynamic cycle has been developed for use at the Experimental Breeder Reactor II by plant operators, engineers, and experimenters. The displays generate a real time thermodynamic model of the plant processes on computer screens to provide a direct indication of the plant performance. Operators and others who view the displays are no longer required to mentally ''construct'' a model of the process before acting. The model based display accurately depicts the plant states. It appears to effectively reduce the gulf of evaluation, which should result in a significant reduction in human operator errors if this plant display approach is adopted by the nuclear industry. Preliminary comments from users, including operators, indicate an overwhelming acceptance of the display approach. The displays incorporate alarm functions as well as levels of detail ''paging'' capability. The system is developed on a computer network which allows the easy addition of displays as well as extra computers. Constructing a complete console can be rapid and inexpensive. 1 ref., 2 figs

  12. Operational characteristics of pediatric radiology: Image display stations

    International Nuclear Information System (INIS)

    Taira, R.K.

    1987-01-01

    The display of diagnostic images is accomplished in the UCLA Pediatric Radiology Clinical Radiology Imaging System (CRIS) using 3 different types of digital viewing stations. These include a low resolution station with six 512 x 512 monitors, a high resolution station with three 1024 x 1024 monitors, and a very high resolution workstation with two 2048 x 2048 monitors. The display stations provide very basic image processing manipulations including zoom and scroll, contrast enhancement, and contrast reversal. The display stations are driven by a computer system which is dedicated for clinical use. During times when the clinical computer is unavailable (maintenance or system malfunction), the 512 x 512 workstation can be switched to operate from a research PACS system in the UCLA Image Processing Laboratory via a broadband communication network. Our initial clinical implementation involves digital viewing for pediatric radiology conferences. Presentation of inpatient cases use the six monitor 512 x 512 multiple viewing station. Later stages of the clinical implementation involve the use of higher resolution displays for the purpose of primary diagnosis from video displays

  13. A Qualitative Method to Estimate HSI Display Complexity

    Energy Technology Data Exchange (ETDEWEB)

    Hugo, Jacques; Gertman, David [Idaho National Laboratory, Idaho (United States)

    2013-04-15

    There is mounting evidence that complex computer system displays in control rooms contribute to cognitive complexity and, thus, to the probability of human error. Research shows that reaction time increases and response accuracy decreases as the number of elements in the display screen increase. However, in terms of supporting the control room operator, approaches focusing on addressing display complexity solely in terms of information density and its location and patterning, will fall short of delivering a properly designed interface. This paper argues that information complexity and semantic complexity are mandatory components when considering display complexity and that the addition of these concepts assists in understanding and resolving differences between designers and the preferences and performance of operators. This paper concludes that a number of simplified methods, when combined, can be used to estimate the impact that a particular display may have on the operator's ability to perform a function accurately and effectively. We present a mixed qualitative and quantitative approach and a method for complexity estimation.

  14. Adaptive controller for volumetric display of neuroimaging studies

    Science.gov (United States)

    Bleiberg, Ben; Senseney, Justin; Caban, Jesus

    2014-03-01

    Volumetric display of medical images is an increasingly relevant method for examining an imaging acquisition as the prevalence of thin-slice imaging increases in clinical studies. Current mouse and keyboard implementations for volumetric control provide neither the sensitivity nor specificity required to manipulate a volumetric display for efficient reading in a clinical setting. Solutions to efficient volumetric manipulation provide more sensitivity by removing the binary nature of actions controlled by keyboard clicks, but specificity is lost because a single action may change display in several directions. When specificity is then further addressed by re-implementing hardware binary functions through the introduction of mode control, the result is a cumbersome interface that fails to achieve the revolutionary benefit required for adoption of a new technology. We address the specificity versus sensitivity problem of volumetric interfaces by providing adaptive positional awareness to the volumetric control device by manipulating communication between hardware driver and existing software methods for volumetric display of medical images. This creates a tethered effect for volumetric display, providing a smooth interface that improves on existing hardware approaches to volumetric scene manipulation.

  15. A comparison of visual and kinesthetic-tactual displays for compensatory tracking

    Science.gov (United States)

    Jagacinski, R. J.; Flach, J. M.; Gilson, R. D.

    1983-01-01

    Recent research on manual tracking with a kinesthetic-tactual (KT) display suggests that under certain conditions it can be an effective alternative or supplement to visual displays. In order to understand better how KT tracking compares with visual tracking, both a critical tracking and stationary single-axis tracking tasks were conducted with and without velocity quickening. In the critical tracking task, the visual displays were superior, however, the quickened KT display was approximately equal to the unquickened visual display. In stationary tracking tasks, subjects adopted lag equalization with the quickened KT and visual displays, and mean-squared error scores were approximately equal. With the unquickened displays, subjects adopted lag-lead equalization, and the visual displays were superior. This superiority was partly due to the servomotor lag in the implementation of the KT display and partly due to modality differences.

  16. Three-dimensional display techniques: description and critique of methods

    International Nuclear Information System (INIS)

    Budinger, T.F.

    1982-01-01

    The recent advances in non invasive medical imaging of 3 dimensional spatial distribution of radionuclides, X-ray attenuation coefficients, and nuclear magnetic resonance parameters necessitate development of a general method for displaying these data. The objective of this paper is to give a systematic description and comparison of known methods for displaying three dimensional data. The discussion of display methods is divided into two major categories: 1) computer-graphics methods which use a two dimensional display screen; and 2) optical methods (such as holography, stereopsis and vari-focal systems)

  17. Multichannel waveform display system

    International Nuclear Information System (INIS)

    Kolvankar, V.G.

    1989-01-01

    For any multichannel data acquisition system, a multichannel paper chart recorder undoubtedly forms an essential part of the system. When deployed on-line, it instantaneously provides, for visual inspection, hard copies of the signal waveforms on common time base at any desired sensitivity and time resolution. Within the country, only a small range of these strip chart recorder s is available, and under stringent specifications imported recorders are often procured. The cost of such recorders may range from 1 to 5 lakhs of rupees in foreign exchange. A system to provide on the oscilloscope a steady display of multichannel waveforms, refreshed from the digital data stored in the memory is developed. The merits and demerits of the display system are compared with that built around a conventional paper chart recorder. Various illustrations of multichannel seismic event data acquired at Gauribidanur seismic array station are also presented. (author). 2 figs

  18. Heterologous surface display on lactic acid bacteria: non-GMO alternative?

    Science.gov (United States)

    Zadravec, Petra; Štrukelj, Borut; Berlec, Aleš

    2015-01-01

    Lactic acid bacteria (LAB) are food-grade hosts for surface display with potential applications in food and therapy. Alternative approaches to surface display on LAB would avoid the use of recombinant DNA technology and genetically-modified organism (GMO)-related regulatory requirements. Non-covalent surface display of proteins can be achieved by fusing them to various cell-wall binding domains, of which the Lysine motif domain (LysM) is particularly well studied. Fusion proteins have been isolated from recombinant bacteria or from their growth medium and displayed on unmodified bacteria, enabling heterologous surface display. This was demonstrated on non-viable cells devoid of protein content, termed bacteria-like particles, and on various species of genus Lactobacillus. Of the latter, Lactobacillus salivarius ATCC 11741 was recently shown to be particularly amenable for LysM-mediated display. Possible regulatory implications of heterologous surface display are discussed, particularly those relevant for the European Union.

  19. Pilot Designed Aircraft Displays in General Aviation: An Exploratory Study and Analysis

    Science.gov (United States)

    Conaway, Cody R.

    From 2001-2011, the General Aviation (GA) fatal accident rate remained unchanged (Duquette & Dorr, 2014) with an overall stagnant accident rate between 2004 and 2013. The leading cause, loss of control in flight (NTSB, 2015b & 2015c) due to pilot inability to recognize approach to stall/spin conditions (NTSB, 2015b & 2016b). In 2013, there were 1,224 GA accidents in the U.S., accounting for 94% of all U.S. aviation accidents and 90% of all U.S. aviation fatalities that year (NTSB, 2015c). Aviation entails multiple challenges for pilots related to task management, procedural errors, perceptual distortions, and cognitive discrepancies. While machine errors in airplanes have continued to decrease over the years, human error still has not (NTSB, 2013). A preliminary analysis of a PC-based, Garmin G1000 flight deck was conducted with 3 professional pilots. Analyses revealed increased task load, opportunities for distraction, confusing perceptual ques, and hindered cognitive performance. Complex usage problems were deeply ingrained in the functionality of the system, forcing pilots to use fallible work arounds, add unnecessary steps, and memorize knob turns or button pushes. Modern computing now has the potential to free GA cockpit designs from knobs, soft keys, or limited display options. Dynamic digital displays might include changes in instrumentation or menu structuring depending on the phase of flight. Airspeed indicators could increase in size to become more salient during landing, simultaneously highlighting pitch angle on Attitude Indicators and automatically decluttering unnecessary information for landing. Likewise, Angle-of-Attack indicators demonstrate a great safety and performance advantage for pilots (Duquette & Dorr, 2014; NTSB, 2015b & 2016b), an instrument typically found in military platforms and now the Icon A5, light-sport aircraft (Icon, 2016). How does the design of pilots' environment---the cockpit---further influence their efficiency and

  20. Time-Sequential Working Wavelength-Selective Filter for Flat Autostereoscopic Displays

    Directory of Open Access Journals (Sweden)

    René de la Barré

    2017-02-01

    Full Text Available A time-sequential working, spatially-multiplexed autostereoscopic 3D display design consisting of a fast switchable RGB-color filter array and a fast color display is presented. The newly-introduced 3D display design is usable as a multi-user display, as well as a single-user system. The wavelength-selective filter barrier emits the light from a larger aperture than common autostereoscopic barrier displays with similar barrier pitch and ascent. Measurements on a demonstrator with commercial display components, simulations and computational evaluations have been carried out to describe the proposed wavelength-selective display design in static states and to show the weak spots of display filters in commercial displays. An optical modelling of wavelength-selective barriers has been used for instance to calculate the light ray distribution properties of that arrangement. In the time-sequential implementation, it is important to avoid that quick eye or eyelid movement leads to visible color artifacts. Therefore, color filter cells, switching faster than conventional LC display cells, must distribute directed light from different primaries at the same time, to create a 3D presentation. For that, electric tunable liquid crystal Fabry–Pérot color filters are presented. They switch on-off the colors red, green and blue in the millisecond regime. Their active areas consist of a sub-micrometer-thick nematic layer sandwiched between dielectric mirrors and indium tin oxide (ITO-electrodes. These cells shall switch narrowband light of red, green or blue. A barrier filter array for a high resolution, glasses-free 3D display has to be equipped with several thousand switchable filter elements having different color apertures.

  1. Flatbed-type 3D display systems using integral imaging method

    Science.gov (United States)

    Hirayama, Yuzo; Nagatani, Hiroyuki; Saishu, Tatsuo; Fukushima, Rieko; Taira, Kazuki

    2006-10-01

    We have developed prototypes of flatbed-type autostereoscopic display systems using one-dimensional integral imaging method. The integral imaging system reproduces light beams similar of those produced by a real object. Our display architecture is suitable for flatbed configurations because it has a large margin for viewing distance and angle and has continuous motion parallax. We have applied our technology to 15.4-inch displays. We realized horizontal resolution of 480 with 12 parallaxes due to adoption of mosaic pixel arrangement of the display panel. It allows viewers to see high quality autostereoscopic images. Viewing the display from angle allows the viewer to experience 3-D images that stand out several centimeters from the surface of the display. Mixed reality of virtual 3-D objects and real objects are also realized on a flatbed display. In seeking reproduction of natural 3-D images on the flatbed display, we developed proprietary software. The fast playback of the CG movie contents and real-time interaction are realized with the aid of a graphics card. Realization of the safety 3-D images to the human beings is very important. Therefore, we have measured the effects on the visual function and evaluated the biological effects. For example, the accommodation and convergence were measured at the same time. The various biological effects are also measured before and after the task of watching 3-D images. We have found that our displays show better results than those to a conventional stereoscopic display. The new technology opens up new areas of application for 3-D displays, including arcade games, e-learning, simulations of buildings and landscapes, and even 3-D menus in restaurants.

  2. Effect of price display on brand luxury perceptions

    OpenAIRE

    Parguel , Béatrice; Delécolle , Thierry; Valette-Florence , Pierre

    2014-01-01

    Based on two experimental studies, this paper investigates the impact of price display in the luxury sector on perceived brand luxury and brand attitude. Using a sample of students, Study1 shows that price display is associated with higher perceived quality, uniqueness, and conspicuousness for a fictitious luxury brand presented in a store window. Using two real luxury brands and a larger sample of consumers, Study 2 confirms the positive effect of price display on the brand’s perceived consp...

  3. Flat panel planar optic display. Revision 4/95

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T.

    1995-05-01

    A prototype 10 inch flat panel Planar Optic display, (POD), screen has been constructed and tested. This display screen is comprised of hundreds of planar optic glass sheets bonded together with a cladding layer between each sheet where each glass sheet represents a vertical line of resolution. The display is 9 inches wide by 5 inches high and approximately 1 inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  4. Orthoscopic real-image display of digital holograms.

    Science.gov (United States)

    Makowski, P L; Kozacki, T; Zaperty, W

    2017-10-01

    We present a practical solution for the long-standing problem of depth inversion in real-image holographic display of digital holograms. It relies on a field lens inserted in front of the spatial light modulator device addressed by a properly processed hologram. The processing algorithm accounts for pixel size and wavelength mismatch between capture and display devices in a way that prevents image deformation. Complete images of large dimensions are observable from one position with a naked eye. We demonstrate the method experimentally on a 10-cm-long 3D object using a single full-HD spatial light modulator, but it can supplement most holographic displays designed to form a real image, including circular wide angle configurations.

  5. Angular distribution of scission neutrons studied with time-dependent Schrödinger equation

    Science.gov (United States)

    Wada, Takahiro; Asano, Tomomasa; Carjan, Nicolae

    2018-03-01

    We investigate the angular distribution of scission neutrons taking account of the effects of fission fragments. The time evolution of the wave function of the scission neutron is obtained by integrating the time-dependent Schrodinger equation numerically. The effects of the fission fragments are taken into account by means of the optical potentials. The angular distribution is strongly modified by the presence of the fragments. In the case of asymmetric fission, it is found that the heavy fragment has stronger effects. Dependence on the initial distribution and on the properties of fission fragments is discussed. We also discuss on the treatment of the boundary to avoid artificial reflections

  6. Student displays of academic competence in the international university

    DEFF Research Database (Denmark)

    Kristiansen, Elisabeth Dalby

    that there may be a connection, on the one hand between students'​ orientation to language as a relevant ressource for displaying academic competence and the project report as the sole product of the students'​ project, and on the other hand between the orientation to multimodal resources for displaying academic......The study presents an ethnomethodologically founded understanding of academic competence as situated social practices displayed in and through social interaction. The project uses Conversation Analysis as a method for describing such displays of competence. The project describes the conversational...... phenomenon of the 'Writing aloud Voice'​ (WAV) and describes how students use WAV sequences to demonstrate their knowledge of and ability to use certain academic conventions for formulating research questions. This constitutes one method for displaying academic competence. The project also describes...

  7. Stronger Association Between Valence- and Arousal Ratings of Affective Pictures with Older Age: Evidence for Variation Across Emotion Categories

    DEFF Research Database (Denmark)

    Mikkelsen, Mai Bjørnskov; Mehlsen, Mimi Yung; Lyby, Marlene Skovgaard

    A sample of older and younger adults rated affective pictures according to valence, arousal and emotion category (happiness, sadness and disgust). Results indicate that older age is associated with a stronger linear association between ratings of arousal and valence. Further, the strength...... of the association vary according to emotion category....

  8. Analysis of Display Latency for 3D Perceptual Experiments

    Science.gov (United States)

    2016-11-01

    Stereoscopic images were displayed on an LG 55 in. Class (54.6 in. diagonal) cinema 3D 1080p 240 Hz LED TV for stimulus display. The 3D display...were nearly identical to those in Recording 3, where we had the variation in stimulus depth and the randomly sampled ISI times. The camera position

  9. Pins and posters: Paradigms for content publication on situated displays.

    Science.gov (United States)

    José, Rui; Pinto, Hélder; Silva, Bruno; Melro, Ana

    2013-01-01

    Public-display systems are still far from being a medium for meeting people's diverse communication goals. Moving toward open displays will require publication paradigms that can overcome the challenges of meaningful engagement and enable users to fully understand and control the publication process. The metaphors of pins and posters have inspired two complementary paradigms for public displays. Researchers implemented these paradigms in the Instant Places system, which they deployed on 10 displays in diverse urban locations for six months. They collected user and system data regarding the users' practices. The findings improve the understanding of what might drive user-generated content in networks of urban displays. Such knowledge can inform the design of tools and procedures for situated publication in public displays.

  10. Smart TV-Smartphone Multiscreen Interactive Middleware for Public Displays

    Directory of Open Access Journals (Sweden)

    Francisco Martinez-Pabon

    2015-01-01

    Full Text Available A new generation of public displays demands high interactive and multiscreen features to enrich people’s experience in new pervasive environments. Traditionally, research on public display interaction has involved mobile devices as the main characters during the use of personal area network technologies such as Bluetooth or NFC. However, the emergent Smart TV model arises as an interesting alternative for the implementation of a new generation of public displays. This is due to its intrinsic connection capabilities with surrounding devices like smartphones or tablets. Nonetheless, the different approaches proposed by the most important vendors are still underdeveloped to support multiscreen and interaction capabilities for modern public displays, because most of them are intended for domestic environments. This research proposes multiscreen interactive middleware for public displays, which was developed from the principles of a loosely coupled interaction model, simplicity, stability, concurrency, low latency, and the usage of open standards and technologies. Moreover, a validation prototype is proposed in one of the most interesting public display scenarios: the advertising.

  11. Smart TV-Smartphone Multiscreen Interactive Middleware for Public Displays

    Science.gov (United States)

    Martinez-Pabon, Francisco; Caicedo-Guerrero, Jaime; Ibarra-Samboni, Jhon Jairo; Ramirez-Gonzalez, Gustavo; Hernández-Leo, Davinia

    2015-01-01

    A new generation of public displays demands high interactive and multiscreen features to enrich people's experience in new pervasive environments. Traditionally, research on public display interaction has involved mobile devices as the main characters during the use of personal area network technologies such as Bluetooth or NFC. However, the emergent Smart TV model arises as an interesting alternative for the implementation of a new generation of public displays. This is due to its intrinsic connection capabilities with surrounding devices like smartphones or tablets. Nonetheless, the different approaches proposed by the most important vendors are still underdeveloped to support multiscreen and interaction capabilities for modern public displays, because most of them are intended for domestic environments. This research proposes multiscreen interactive middleware for public displays, which was developed from the principles of a loosely coupled interaction model, simplicity, stability, concurrency, low latency, and the usage of open standards and technologies. Moreover, a validation prototype is proposed in one of the most interesting public display scenarios: the advertising. PMID:25950018

  12. Selection is stronger in early-versus-late stages of divergence in a Neotropical livebearing fish.

    Science.gov (United States)

    Ingley, Spencer J; Johnson, Jerald B

    2016-03-01

    How selection acts to drive trait evolution at different stages of divergence is of fundamental importance in our understanding of the origins of biodiversity. Yet, most studies have focused on a single point along an evolutionary trajectory. Here, we provide a case study evaluating the strength of divergent selection acting on life-history traits at early-versus-late stages of divergence in Brachyrhaphis fishes. We find that the difference in selection is stronger in the early-diverged population than the late-diverged population, and that trait differences acquired early are maintained over time. © 2016 The Author(s).

  13. Super long viewing distance light homogeneous emitting three-dimensional display

    Science.gov (United States)

    Liao, Hongen

    2015-04-01

    Three-dimensional (3D) display technology has continuously been attracting public attention with the progress in today's 3D television and mature display technologies. The primary characteristics of conventional glasses-free autostereoscopic displays, such as spatial resolution, image depths, and viewing angle, are often limited due to the use of optical lenses or optical gratings. We present a 3D display using MEMS-scanning-mechanism-based light homogeneous emitting (LHE) approach and demonstrate that the display can directly generate an autostereoscopic 3D image without the need for optical lenses or gratings. The generated 3D image has the advantages of non-aberration and a high-definition spatial resolution, making it the first to exhibit animated 3D images with image depth of six meters. Our LHE 3D display approach can be used to generate a natural flat-panel 3D display with super long viewing distance and alternative real-time image update.

  14. Application of verification and validation on safety parameter display systems

    International Nuclear Information System (INIS)

    Thomas, N.C.

    1983-01-01

    Offers some explanation of how verification and validation (VandV) can support development and licensing of the Safety Parameter Display Systems (SPDS). Advocates that VandV can be more readily accepted within the nuclear industry if a better understanding exists of what the objectives of VandV are and should be. Includes a discussion regarding a reasonable balance of costs and benefits of VandV as applied to the SPDS and to other digital systems. Represents the author's perception of the regulator's perspective based on background information and experience, and discussions with regulators about their current concerns and objectives. Suggests that the introduction of the SPDS into the Control Room is a first step towards growing dependency on use of computers

  15. Emotional display rules and emotional labor: the moderating role of commitment.

    Science.gov (United States)

    Gosserand, Robin H; Diefendorff, James M

    2005-11-01

    The authors examined whether commitment to emotional display rules is a necessary condition for emotional display rules to affect behavior at work. Results using structural equation modeling revealed that display rule commitment moderated the relationships of emotional display rule perceptions with surface acting, deep acting, and positive affective delivery at work, such that the relationships were strong and positive when commitment to display rules was high and weak when commitment to display rules was low. These findings suggest that motivation plays a role in the emotional labor process in that individuals must be committed to display rules for these rules to affect behavior. ((c) 2005 APA, all rights reserved).

  16. Yeast Surface Display of Two Proteins Previously Shown to Be Protective Against White Spot Syndrome Virus (WSSV) in Shrimp.

    Science.gov (United States)

    Ananphongmanee, Vorawit; Srisala, Jiraporn; Sritunyalucksana, Kallaya; Boonchird, Chuenchit

    2015-01-01

    Cell surface display using the yeasts Saccharomyces cerevisiae and Pichia pastoris has been extensively developed for application in bioindustrial processes. Due to the rigid structure of their cell walls, a number of proteins have been successfully displayed on their cell surfaces. It was previously reported that the viral binding protein Rab7 from the giant tiger shrimp Penaeus monodon (PmRab7) and its binding partner envelope protein VP28 of white spot syndrome virus (WSSV) could independently protect shrimp against WSSV infection. Thus, we aimed to display these two proteins independently on the cell surfaces of 2 yeast clones with the ultimate goal of using a mixture of the two clones as an orally deliverable, antiviral agent to protect shrimp against WSSV infection. PmRab7 and VP28 were modified by N-terminal tagging to the C-terminal half of S. cerevisiae α-agglutinin. DNA fragments, harboring fused-gene expression cassettes under control of an alcohol oxidase I (AOX1) promoter were constructed and used to transform the yeast cells. Immunofluorescence microscopy with antibodies specific to both proteins demonstrated that mutated PmRab7 (mPmRab7) and partial VP28 (pVP28) were localized on the cell surfaces of the respective clones, and fluorescence intensity for each was significantly higher than that of control cells by flow cytometry. Enzyme-linked immunosorbant assay (ELISA) using cells displaying mPmRab7 or pVP28 revealed that the binding of specific antibodies for each was dose-dependent, and could be saturated. In addition, the binding of mPmRab7-expressing cells with free VP28, and vice versa was dose dependent. Binding between the two surface-expressed proteins was confirmed by an assay showing agglutination between cells expressing complementary mPmRab7 and pVP28. In summary, our genetically engineered P. pastoris can display biologically active mPmRab7 and pVP28 and is now ready for evaluation of efficacy in protecting shrimp against WSSV by oral

  17. Yeast Surface Display of Two Proteins Previously Shown to Be Protective Against White Spot Syndrome Virus (WSSV in Shrimp.

    Directory of Open Access Journals (Sweden)

    Vorawit Ananphongmanee

    Full Text Available Cell surface display using the yeasts Saccharomyces cerevisiae and Pichia pastoris has been extensively developed for application in bioindustrial processes. Due to the rigid structure of their cell walls, a number of proteins have been successfully displayed on their cell surfaces. It was previously reported that the viral binding protein Rab7 from the giant tiger shrimp Penaeus monodon (PmRab7 and its binding partner envelope protein VP28 of white spot syndrome virus (WSSV could independently protect shrimp against WSSV infection. Thus, we aimed to display these two proteins independently on the cell surfaces of 2 yeast clones with the ultimate goal of using a mixture of the two clones as an orally deliverable, antiviral agent to protect shrimp against WSSV infection. PmRab7 and VP28 were modified by N-terminal tagging to the C-terminal half of S. cerevisiae α-agglutinin. DNA fragments, harboring fused-gene expression cassettes under control of an alcohol oxidase I (AOX1 promoter were constructed and used to transform the yeast cells. Immunofluorescence microscopy with antibodies specific to both proteins demonstrated that mutated PmRab7 (mPmRab7 and partial VP28 (pVP28 were localized on the cell surfaces of the respective clones, and fluorescence intensity for each was significantly higher than that of control cells by flow cytometry. Enzyme-linked immunosorbant assay (ELISA using cells displaying mPmRab7 or pVP28 revealed that the binding of specific antibodies for each was dose-dependent, and could be saturated. In addition, the binding of mPmRab7-expressing cells with free VP28, and vice versa was dose dependent. Binding between the two surface-expressed proteins was confirmed by an assay showing agglutination between cells expressing complementary mPmRab7 and pVP28. In summary, our genetically engineered P. pastoris can display biologically active mPmRab7 and pVP28 and is now ready for evaluation of efficacy in protecting shrimp against

  18. Smart displays in intelligent environments: a vision for Europe 2007+

    Science.gov (United States)

    Maiser, Eric

    2005-07-01

    Future electronic systems will create "ambient intelligence": environments that recognise us, applications which can be used intuitively. Displays will always be a key part of such systems, because visual information provides a densely packed fast link to our brain. European researchers and suppliers are global drivers in display innovation - on the other hand Europe is a major influence on the market for display applications. However, today displays are produced in Asia, European research and development is scattered, and lacks both collaboration and a strong production base. That is why adria, a European network for the displays community, has been formed: Its goal is to substantially enhance the standing of the displays industry in Europe by creating a common knowledge base, by generating a common vision for a display future in Europe and by establishing appreciated services for a future association that will serve as a "one-stop-shop" for the community. To effectively start the discussion, a vision paper1 has been compiled including inputs from 95 individuals from 17 European countries. It describes the state displays research and industry are in today and estimates future developments displays will take towards intelligent systems in the next decade and beyond. Recommendations are made to reinforce the displays industry in a sustainable way building on existing strengths in research, as well as in the materials and equipment sectors. The adria network, its roadmapping approach as well as key projections and findings of the vision paper are described here, going beyond the topic of Organic Light Emitting Diodes alone.

  19. Scale dependence and small-x behaviour of polarized parton distributions

    International Nuclear Information System (INIS)

    Ball, R.D.; Forte, S.; Ridolfi, G.

    1995-01-01

    We discuss perturbative evolution of the polarized structure function g 1 in the (x, Q 2 ) plane, with special regard to the small-x region. We determine g 1 in terms of polarized quark and gluon distributions using coefficient functions to order α s . At small x g 1 then displays substantial scale dependence, which necessarily implies a corresponding scale dependence in the large-x region. This scale dependence has significant consequences for the extraction of the first moment from the experimental data, reducing its value while increasing the error. Conversely, the scale dependence may be used to constrain the size of the polarized gluon distribution. ((orig.))

  20. Scale dependence and small x behaviour of polarized parton distributions

    CERN Document Server

    Ball, R D; Ridolfi, G; Forte, S; Ridolfi, G

    1995-01-01

    We discuss perturbative evolution of the polarized structure function g_1 in the (x,Q^2) plane, with special regard to the small-x region. We determine g_1 in terms of polarized quark and gluon distributions using coefficient functions to order alpha_s. At small x g_1 then displays substantial scale dependence, which necessarily implies a corresponding scale dependence in the large-x region. This scale dependence has significant consequences for the extraction of the first moment from the experimental data, reducing its value while increasing the error. Conversely, the scale dependence may be used to constrain the size of the polarized gluon distribution.

  1. Calcium-dependent protein kinase CPK31 interacts with arsenic transporter AtNIP1;1 and regulates arsenite uptake in Arabidopsis thaliana.

    Directory of Open Access Journals (Sweden)

    Ruijie Ji

    Full Text Available Although arsenite [As(III] is non-essential and toxic for plants, it is effectively absorbed through various transporters into the roots. Here we identified a calcium-dependent protein kinase (CPK31 response for As(III tolerance in Arabidopsis. We identified CPK31 as an interacting protein of a nodulin 26-like intrinsic protein (NIP1;1, an aquaporin involved in As(III uptake. Similarly to the nip1;1 mutants, the loss-of-function mutants of CPK31 improved the tolerance against As(III but not As(V, and accumulated less As(III in roots than that of the wild-type plants. The promoter-β-glucuronidase and quantitative Real-Time PCR analysis revealed that CPK31 displayed overlapping expression profiles with NIP1;1 in the roots, suggesting that they might function together in roots. Indeed, the cpk31 nip1;1 double mutants exhibited stronger As(III tolerance than cpk31 mutants, but similar to nip1;1 mutants, supporting the idea that CPK31 might serve as an upstream regulator of NIP1;1. Furthermore, transient CPK31 overexpression induced by dexamethasone caused the decrease in As(III tolerance of transgenic Arabidopsis lines. These findings reveal that CPK31 is a key factor in As(III response in plants.

  2. Versatile microbial surface-display for environmental remediation and biofuels production

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Cindy H.; Mulchandani, Ashok; Chen, wilfred

    2008-02-14

    Surface display is a powerful technique that utilizes natural microbial functional components to express proteins or peptides on the cell exterior. Since the reporting of the first surface-display system in the mid-1980s, a variety of new systems have been reported for yeast, Gram-positive and Gram-negative bacteria. Non-conventional display methods are emerging, eliminating the generation of genetically modified microorganisms. Cells with surface display are used as biocatalysts, biosorbents and biostimulants. Microbial cell-surface display has proven to be extremely important for numerous applications ranging from combinatorial library screening and protein engineering to bioremediation and biofuels production.

  3. An IBM-Compatible 640 X 200 Electroluminescent (EL) Display Monitor

    Science.gov (United States)

    Gullick, Paul; Schmachtenberg, Richard; Laakso, Carl

    1986-05-01

    An electroluminescent flat-panel display has been developed and recently introduced that fills any of the needs of the portable computer market. The display is very thin, yet rugged enough for the rigors of portability. It is highly integrated, and very reliable. It has the crisp and clear display image that is typical of high quality electroluminescent displays. The unit has a pixel matrix organization and pixel dimensions that are not only asthetically and ergonomically pleasing, but also make the display compatible with the most widely used software packages run on today's personal computers (Figure 1).

  4. Pester power: snackfoods displayed at supermarket checkouts in Melbourne, Australia.

    Science.gov (United States)

    Dixon, Helen; Scully, Maree; Parkinson, Kristiina

    2006-08-01

    To establish the amount and accessibility of snack food displayed at supermarket checkouts located in Melbourne, Australia. Observational survey of 24 randomly selected supermarkets situated within a 20-kilometre radius of Melbourne's General Post Office. Individual checkouts within each store (n=257) were observed to determine the types of items that were displayed, how they were promoted, and whether they were within the reach of children. All supermarkets surveyed displayed food products at their checkouts, with most checkouts displaying chocolate (87%), gum (81%) and sweets (80%). Only 7% of checkouts had their display of foods or drinks out of the reach of children. Foods displayed at supermarket checkouts in Melbourne are predominantly energy-dense confectionery items. They are often promoted in a way that targets children and encourages parents to impulse buy for their children.

  5. GROPE-1: a computer display to the sense of feel

    Energy Technology Data Exchange (ETDEWEB)

    Batter, J J; Brooks, Jr, F P

    1972-01-01

    A computer display system was built and programmed that exerts programmable forces on the fingers as one moves a knob in a plane. The system includes a movable carriage, position sensors, mechanisms for converting computer outputs to forces, a visual graphic display, and, most important, the programs. A controlled experiment measured the utility of force output. Two groups were taught topics in elementary field theory and exercised with the computer displays. One group had force displayed to the hand as well as to the eye. The other had visual display only. The experiment was repeated with three different sets of students. The force-display groups performed significantly better in two of the three cases; in the third case, interest in the subject was low and this seems to account for low performance.

  6. Reconfigurable Auditory-Visual Display

    Science.gov (United States)

    Begault, Durand R. (Inventor); Anderson, Mark R. (Inventor); McClain, Bryan (Inventor); Miller, Joel D. (Inventor)

    2008-01-01

    System and method for visual and audible communication between a central operator and N mobile communicators (N greater than or equal to 2), including an operator transceiver and interface, configured to receive and display, for the operator, visually perceptible and audibly perceptible signals from each of the mobile communicators. The interface (1) presents an audible signal from each communicator as if the audible signal is received from a different location relative to the operator and (2) allows the operator to select, to assign priority to, and to display, the visual signals and the audible signals received from a specified communicator. Each communicator has an associated signal transmitter that is configured to transmit at least one of the visual signals and the audio signal associated with the communicator, where at least one of the signal transmitters includes at least one sensor that senses and transmits a sensor value representing a selected environmental or physiological parameter associated with the communicator.

  7. Interactive computer graphics displays for hierarchical data structures

    International Nuclear Information System (INIS)

    Cahn, D.F.; Murano, C.V.

    1980-05-01

    An interactive computer graphical display program was developed as an aid to user visualization and manipulation of hierarchically structured data systems such as thesauri. In the present configuration, a thesaurus term and its primary and secondary conceptual neighbors are presented to the user in tree graph form on a CRT; the user then designates, via light pen or keyboard, any of the neighbors as the next term of interest and receives a new display centered on this term. By successive specification of broader, narrower, and related terms, the user can course rapidly through the thesaurus space and refine his search file. At any stage, he deals with a term-centered, conceptually meaningful picture of a localized portion of the thesaurus, and is freed from the artificial difficulties of handling the traditional alphabetized thesaurus. Intentional limitation of the associative range of each display frame, and the use of color, case, and interconnecting vectors to encode relationships among terms, enhance interpretability of the display. Facile movement through the term space, provided by interactive computation, allows the display to remain simple, and is an essential element of the system. 3 figures

  8. Instrumentation for on-line mountain range displays

    International Nuclear Information System (INIS)

    van Asselt, W.K.; Ahrens, L.A.

    1994-01-01

    A method to obtain and process 'mountain range' displays of beam signals is described. A custom-made trigger generator and a digital oscilloscope are used for the data acquisition and the graphical interface package LabVIEW is used to process the data. High resolution displays of wall monitor signals updating every AGS cycle have proven very powerful as a beam diagnostic

  9. Advanced display concepts in nuclear control rooms

    International Nuclear Information System (INIS)

    Clark, M.T.; Banks, W.W.; Blackman, H.S.; Gertman, D.I.

    1982-01-01

    Precursors necessary for the development of a full-scale predictor display/control system have been under development since the mid 1940's. The predictor display itself has been available for use in manual control systems since 1958. However, the nuclear industry has not yet explored the uses and benefits of predictor systems. The purpose of this paper is to provide information on the application of this technology to the nuclear industry. The possibility of employing a simulation-based control system for nuclear plant systems that currently use conventional auto/manual schemes is discussed. By employing simulation-based systems, a predictor display could be made available to the operator during manual operations, thus facilitating control without outwardly affecting the overall control scheme

  10. Secondary visual workload capability with primary visual and kinesthetic-tactual displays

    Science.gov (United States)

    Gilson, R. D.; Burke, M. W.; Jagacinski, R. J.

    1978-01-01

    Subjects performed a cross-adaptive tracking task with a visual secondary display and either a visual or a quickened kinesthetic-tactual (K-T) primary display. The quickened K-T display resulted in superior secondary task performance. Comparisons of secondary workload capability with integrated and separated visual displays indicated that the superiority of the quickened K-T display was not simply due to the elimination of visual scanning. When subjects did not have to perform a secondary task, there was no significant difference between visual and quickened K-T displays in performing a critical tracking task.

  11. Issues in symbol design for electronic displays of navigation information

    Science.gov (United States)

    2004-10-24

    An increasing number of electronic displays, ranging from small hand-held displays for general aviation to installed displays for air transport, are showing navigation information, such as symbols representing navigational aids. The wide range of dis...

  12. Study finds stronger nicotine dependency associated with higher risk of lung cancer

    Science.gov (United States)

    NCI headed study finds people who are highly addicted to nicotine -- those who smoke their first cigarette within five minutes after awakening -- are at higher risk of developing lung cancer than those who wait for an hour or more to smoke.

  13. Intraspecific density dependence and a guild of consumers coexisting on one resource.

    Science.gov (United States)

    McPeek, Mark A

    2012-12-01

    The importance of negative intraspecific density dependence to promoting species coexistence in a community is well accepted. However, such mechanisms are typically omitted from more explicit models of community dynamics. Here I analyze a variation of the Rosenzweig-MacArthur consumer-resource model that includes negative intraspecific density dependence for consumers to explore its effect on the coexistence of multiple consumers feeding on a single resource. This analysis demonstrates that a guild of multiple consumers can easily coexist on a single resource if each limits its own abundance to some degree, and stronger intraspecific density dependence permits a wider variety of consumers to coexist. The mechanism permitting multiple consumers to coexist works in a fashion similar to apparent competition or to each consumer having its own specialized predator. These results argue for a more explicit emphasis on how negative intraspecific density dependence is generated and how these mechanisms combine with species interactions to shape overall community structure.

  14. Performance analysis of multi-primary color display based on OLEDs/PLEDs

    Science.gov (United States)

    Xiong, Yan; Deng, Fei; Xu, Shan; Gao, Shufang

    2017-09-01

    A multi-primary color display, such as the six-primary color format, is a solution in expanding the color gamut of a full-color flat panel display. The performance of a multi-primary color display based on organic/polymer light-emitting diodes was analyzed in this study using the fitting curves of the characteristics of devices (i.e., current density, voltage, luminance). A white emitter was introduced into a six-primary color format to form a seven-primary color format that contributes to energy saving, and the ratio of power efficiency of a seven-primary color display to that of a six-primary color display would increase from 1.027 to 1.061 by using emitting diodes with different electroluminescent efficiencies. Different color matching schemes of the seven-primary color format display were compared in a uniform color space, and the scheme of the color reproduction did not significantly affect the display performance. Although seven- and six-primary color format displays benefit a full-color display with higher quality, they are less efficient than three-primary (i.e., red (R), green (G), and blue (B), RGB) and four-primary (i.e., RGB+white, RGBW) color format displays. For the seven-primary color formats considered in this study, the advantages of white-primary-added display with efficiently developed light-emitting devices were more evident than the format without a white primary.

  15. A head-mounted display-based personal integrated-image monitoring system for transurethral resection of the prostate.

    Science.gov (United States)

    Yoshida, Soichiro; Kihara, Kazunori; Takeshita, Hideki; Fujii, Yasuhisa

    2014-12-01

    The head-mounted display (HMD) is a new image monitoring system. We developed the Personal Integrated-image Monitoring System (PIM System) using the HMD (HMZ-T2, Sony Corporation, Tokyo, Japan) in combination with video splitters and multiplexers as a surgical guide system for transurethral resection of the prostate (TURP). The imaging information obtained from the cystoscope, the transurethral ultrasonography (TRUS), the video camera attached to the HMD, and the patient's vital signs monitor were split and integrated by the PIM System and a composite image was displayed by the HMD using a four-split screen technique. Wearing the HMD, the lead surgeon and the assistant could simultaneously and continuously monitor the same information displayed by the HMD in an ergonomically efficient posture. Each participant could independently rearrange the images comprising the composite image depending on the engaging step. Two benign prostatic hyperplasia (BPH) patients underwent TURP performed by surgeons guided with this system. In both cases, the TURP procedure was successfully performed, and their postoperative clinical courses had no remarkable unfavorable events. During the procedure, none of the participants experienced any HMD-wear related adverse effects or reported any discomfort.

  16. Strategy-oriented display concept to assist severe accident management

    International Nuclear Information System (INIS)

    Jeong, Kwangsub; Ha, Jaejoo

    2000-01-01

    The Critical Function Monitoring System (CFMS) is a typical Safety Parameter Display System (SPDS) to assist the operation of Korean Standard Nuclear Power Plants during normal and emergency operation, and SPDS for severe accident is being developed in Korea. When the existing CFMS is used under a severe accident situation, some problems are expected from: (1) different design basis, i.e. prevention of core melt vs. protection of radiation release to environment, (2) different parameters for decision-making, and (3) different domain and depth of information to restore the plant. To resolve the above problems, a concept, 'Strategy-Oriented Information Display' concept, for displaying information for severe accident management is developed in this paper. Whereas the existing SPDS structure is based on the critical safety function, the developed concept is based on the severe accident management strategy. The display for each strategy includes the plant parameters to check the status of plant and component with the logical or graphical views necessary for executing the strategy. As the application of the proposed concept, KAERI is developing a display system, the prototype severe accident SPDS, Severe Accident Management Display System (SAMDIS), to assist plant personnel for executing Korean Severe Accident Management Guidelines. CFMS is developed for a general display suitable to all situations with various displays. On the contrary, SAMDIS provides all the relevant information on one screen based on the proposed concept. The SAMDIS screen shows more extensive area than CFMS and thus plant personnel can recognize the overall plant status at a glance. This concept is quite effective when used with severe accident management guidelines because of the relatively macroscopic characteristics of a severe accident management strategy. (author)

  17. Electro Spray Method for Flexible Display

    Science.gov (United States)

    2016-05-12

    AFRL-AFOSR-JP-TR-2016-0095 Electro Spray Method for Flexible Display Yukiharu Uraoka NARA INSTITUTE OF SCIENCE AND TECHNOLOGY Final Report 11/26/2016...DATES COVERED (From - To)  20 Mar 2013 to 19 May 2016 4. TITLE AND SUBTITLE Electro Spray Method for Flexible Display 5a.  CONTRACT NUMBER 5b.  GRANT...NUMBER FA2386-13-1-4024 5c.  PROGRAM ELEMENT NUMBER 61102F 6. AUTHOR(S) Yukiharu Uraoka 5d.  PROJECT NUMBER 5e.  TASK NUMBER 5f.   WORK UNIT NUMBER 7

  18. Paradigm for expert display systems in nuclear plant and elsewhere

    International Nuclear Information System (INIS)

    Gabriel, J.R.

    1986-02-01

    Display of relevant data concerning plant operation has been a concern of the nuclear industry from its beginnings. Since the incident at Three Mile Island, this matter has had much careful scrutiny. L. Beltracchi, in particular, has originated a sequence of important steps to improve the operator's ability to recognize plant states and their changes. In the early 1980's, Beltracchi (1983, 1984) proposed a display based on the Rankine cycle for light water reactors. More recently, in an unpublished work (1986b), he described an extension that includes a small, rule-based system in the display program, drawing inferences about plant operation from sensor readings, and displaying those inferences on the Rankine display. Our paper examines Beltracchi's rule-based display from the perspective of knowledge bases. Earlier (Gabriel, 1983) we noted that analytical models of system behavior are just as much a knowledge base as are the rules of a conventional expert system. The problem of finding useful displays for a complex plant is discussed from this perspective. We then present a paradigm for developing designs with properties similar to those in Beltracchi's Rankine cycle display. Finally, to clarify the issue, we give a small example from an imaginary plant

  19. Is eye damage caused by stereoscopic displays?

    Science.gov (United States)

    Mayer, Udo; Neumann, Markus D.; Kubbat, Wolfgang; Landau, Kurt

    2000-05-01

    A normal developing child will achieve emmetropia in youth and maintain it. Thereby cornea, lens and axial length of the eye grow astonishingly coordinated. In the last years research has evidenced that this coordinated growing process is a visually controlled closed loop. The mechanism has been studied particularly in animals. It was found that the growth of the axial length of the eyeball is controlled by image focus information from the retina. It was shown that maladjustment can occur by this visually-guided growth control mechanism that result in ametropia. Thereby it has been proven that e.g. short-sightedness is not only caused by heredity, but is acquired under certain visual conditions. It is shown that these conditions are similar to the conditions of viewing stereoscopic displays where the normal accommodation convergence coupling is disjoint. An evaluation is given of the potential of damaging the eyes by viewing stereoscopic displays. Concerning this, different viewing methods for stereoscopic displays are evaluated. Moreover, clues are given how the environment and display conditions shall be set and what users shall be chosen to minimize the risk of eye damages.

  20. Market trends in the projection display industry

    Science.gov (United States)

    Dash, Sweta

    2000-04-01

    The projection display industry represents a multibillion- dollar market that includes four distinct technologies. High-volume consumer products and high-value business products drive the market, with different technologies being used in different application markets. The consumer market is dominated by rear CRT technology, especially in the projection television segment. But rear LCD (liquid crystal display) and rear reflective (DLP, or Digital Light ProcessingTM) televisions are slowly emerging as future competitors to rear CRT projectors. Front CRT projectors are still popular in the high-end home theater market. Front LCD technology and front DLP technology dominate the business market. Traditional light valve technology was the only solution for applications requiring high light outputs, but new three-chip DLP projectors meet the higher light output requirements at a lower price. In the last few years the strongest growth has been in the business market for multimedia presentation applications. This growth was due to the continued increase in display pixel formats, the continued reduction in projector weight, and the improved price/performance ratio. The projection display market will grow at a significant rate during the next five years, driven by the growth in ultraportable (market to digital and HDTV products.