WorldWideScience

Sample records for displayed higher levels

  1. Human isolates of Salmonella enterica serovar Typhimurium from Taiwan displayed significantly higher levels of antimicrobial resistance than those from Denmark.

    Science.gov (United States)

    Torpdahl, Mia; Lauderdale, Tsai-Ling; Liang, Shiu-Yun; Li, Ishien; Wei, Sung-Hsi; Chiou, Chien-Shun

    2013-02-01

    Salmonella enterica serovar Typhimurium is a major zoonotic pathogen with a high prevalence of antimicrobial resistance. This pathogen can disseminate across borders and spread far distances via the food trade and international travel. In this study, we compared the genotypes and antimicrobial resistance of 378 S. Typhimurium isolates collected in Taiwan and Denmark between 2009 and 2010. Genotyping revealed that many S. Typhimurium strains were concurrently circulating in Taiwan, Denmark and other countries in 2009 and 2010. When compared to the isolates collected from Denmark, the isolates from Taiwan displayed a significantly higher level of resistance to 11 of the 12 tested antimicrobials. Seven genetic clusters (A-G) were designated for the isolates. A high percentage of the isolates in genetic clusters C, F and G were multidrug-resistant. Of the isolates in cluster C, 79.2% were ASSuT-resistant, characterized by resistance to ampicillin, streptomycin, sulfamethoxazole, and tetracycline. In cluster F, 84.1% of the isolates were ACSSuT-resistant (resistant to ASSuT and chloramphenicol). Cluster G was unique to Taiwan and characterized in most isolates by the absence of three VNTRs (ST20, ST30 and STTR6) as well as a variety of multidrug resistance profiles. This cluster exhibited very high to extremely high levels of resistance to several first-line drugs, and among the seven clusters, it displayed the highest levels of resistance to cefotaxime and ceftazidime, ciprofloxacin and gentamicin. The high prevalence of antimicrobial resistance in S. Typhimurium from Taiwan highlights the necessity to strictly regulate the use of antimicrobials in the agriculture and human health care sectors. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. [Influence of different lighting levels at workstations with video display terminals on operators' work efficiency].

    Science.gov (United States)

    Janosik, Elzbieta; Grzesik, Jan

    2003-01-01

    The aim of this work was to evaluate the influence of different lighting levels at workstations with video display terminals (VDTs) on the course of the operators' visual work, and to determine the optimal levels of lighting at VDT workstations. For two kinds of job (entry of figures from a typescript and edition of the text displayed on the screen), the work capacity, the degree of the visual strain and the operators' subjective symptoms were determined for four lighting levels (200, 300, 500 and 750 lx). It was found that the work at VDT workstations may overload the visual system and cause eyes complaints as well as the reduction of accommodation or convergence strength. It was also noted that the edition of the text displayed on the screen is more burdening for operators than the entry of figures from a typescript. Moreover, the examination results showed that the lighting at VDT workstations should be higher than 200 lx and that 300 lx makes the work conditions most comfortable during the entry of figures from a typescript, and 500 lx during the edition of the text displayed on the screen.

  3. JAVA Stereo Display Toolkit

    Science.gov (United States)

    Edmonds, Karina

    2008-01-01

    This toolkit provides a common interface for displaying graphical user interface (GUI) components in stereo using either specialized stereo display hardware (e.g., liquid crystal shutter or polarized glasses) or anaglyph display (red/blue glasses) on standard workstation displays. An application using this toolkit will work without modification in either environment, allowing stereo software to reach a wider audience without sacrificing high-quality display on dedicated hardware. The toolkit is written in Java for use with the Swing GUI Toolkit and has cross-platform compatibility. It hooks into the graphics system, allowing any standard Swing component to be displayed in stereo. It uses the OpenGL graphics library to control the stereo hardware and to perform the rendering. It also supports anaglyph and special stereo hardware using the same API (application-program interface), and has the ability to simulate color stereo in anaglyph mode by combining the red band of the left image with the green/blue bands of the right image. This is a low-level toolkit that accomplishes simply the display of components (including the JadeDisplay image display component). It does not include higher-level functions such as disparity adjustment, 3D cursor, or overlays all of which can be built using this toolkit.

  4. An Evaluation of Detect and Avoid (DAA) Displays for Unmanned Aircraft Systems: The Effect of Information Level and Display Location on Pilot Performance

    Science.gov (United States)

    Fern, Lisa; Rorie, R. Conrad; Pack, Jessica S.; Shively, R. Jay; Draper, Mark H.

    2015-01-01

    A consortium of government, industry and academia is currently working to establish minimum operational performance standards for Detect and Avoid (DAA) and Control and Communications (C2) systems in order to enable broader integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS). One subset of these performance standards will need to address the DAA display requirements that support an acceptable level of pilot performance. From a pilot's perspective, the DAA task is the maintenance of self separation and collision avoidance from other aircraft, utilizing the available information and controls within the Ground Control Station (GCS), including the DAA display. The pilot-in-the-loop DAA task requires the pilot to carry out three major functions: 1) detect a potential threat, 2) determine an appropriate resolution maneuver, and 3) execute that resolution maneuver via the GCS control and navigation interface(s). The purpose of the present study was to examine two main questions with respect to DAA display considerations that could impact pilots' ability to maintain well clear from other aircraft. First, what is the effect of a minimum (or basic) information display compared to an advanced information display on pilot performance? Second, what is the effect of display location on UAS pilot performance? Two levels of information level (basic, advanced) were compared across two levels of display location (standalone, integrated), for a total of four displays. The authors propose an eight-stage pilot-DAA interaction timeline from which several pilot response time metrics can be extracted. These metrics were compared across the four display conditions. The results indicate that the advanced displays had faster overall response times compared to the basic displays, however, there were no significant differences between the standalone and integrated displays. Implications of the findings on understanding pilot performance on the DAA task, the

  5. Higher-level Innovization

    DEFF Research Database (Denmark)

    Bandaru, Sunith; Tutum, Cem Celal; Deb, Kalyanmoy

    2011-01-01

    we introduce the higher-level innovization task through an application of a manufacturing process simulation for the Friction Stir Welding (FSW) process where commonalities among two different Pareto-optimal fronts are analyzed. Multiple design rules are simultaneously deciphered from each front...

  6. Synthetic vision display evaluation studies

    Science.gov (United States)

    Regal, David M.; Whittington, David H.

    1994-01-01

    The goal of this research was to help us understand the display requirements for a synthetic vision system for the High Speed Civil Transport (HSCT). Four experiments were conducted to examine the effects of different levels of perceptual cue complexity in displays used by pilots in a flare and landing task. Increased levels of texture mapping of terrain and runway produced mixed results, including harder but shorter landings and a lower flare initiation altitude. Under higher workload conditions, increased texture resulted in an improvement in performance. An increase in familiar size cues did not result in improved performance. Only a small difference was found between displays using two patterns of high resolution texture mapping. The effects of increased perceptual cue complexity on performance was not as strong as would be predicted from the pilot's subjective reports or from related literature. A description of the role of a synthetic vision system in the High Speed Civil Transport is provide along with a literature review covering applied research related to perceptual cue usage in aircraft displays.

  7. Automatic adjustment of display window (gray-level condition) for MR images using neural networks

    International Nuclear Information System (INIS)

    Ohhashi, Akinami; Nambu, Kyojiro.

    1992-01-01

    We have developed a system to automatically adjust the display window width and level (WWL) for MR images using neural networks. There were three main points in the development of our system as follows: 1) We defined an index for the clarity of a displayed image, and called 'EW'. EW is a quantitative measure of the clarity of an image displayed in a certain WWL, and can be derived from the difference between gray-level with the WWL adjusted by a human expert and with a certain WWL. 2) We extracted a group of six features from a gray-level histogram of a displayed image. We designed two neural networks which are able to learn the relationship between these features and the desired output (teaching signal), 'EQ', which is normalized to 0 to 1.0 from EW. Two neural networks were used to share the patterns to be learned; one learns a variety of patterns with less accuracy, and the other learns similar patterns with accuracy. Learning was performed using a back-propagation method. As a result, the neural networks after learning are able to provide a quantitative measure, 'Q', of the clarity of images displayed in the designated WWL. 3) Using the 'Hill climbing' method, we have been able to determine the best possible WWL for a displaying image. We have tested this technique for MR brain images. The results show that this system can adjust WWL comparable to that adjusted by a human expert for the majority of test images. The neural network is effective for the automatic adjustment of the display window for MR images. We are now studying the application of this method to MR images of another regions. (author)

  8. Coherence across consciousness levels: Symmetric visual displays spare working memory resources.

    Science.gov (United States)

    Dumitru, Magda L

    2015-12-15

    Two studies demonstrate that the need for coherence could nudge individuals to use structural similarities between binary visual displays and two concurrent cognitive tasks to unduly solve the latter in similar fashion. In an overt truth-judgement task, participants decided whether symmetric colourful displays matched conjunction or disjunction descriptions (e.g., "the black and/or the orange"). In the simultaneous covert categorisation task, they decided whether a colour name (e.g., "black") described a two-colour object or half of a single-colour object. Two response patterns emerged as follows. Participants either acknowledged or rejected matches between disjunction descriptions and two visual stimuli and, similarly, either acknowledged or rejected matches between single colour names and two-colour objects or between single colour names and half of single-colour objects. These findings confirm the coherence hypothesis, highlight the role of coherence in preserving working-memory resources, and demonstrate an interaction between high-level and low-level consciousness. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. The effect of display movement angle, indicator type and display location on control/display stereotype strength.

    Science.gov (United States)

    Hoffmann, Errol R; Chan, Alan H S

    2017-08-01

    Much research on stereotype strength relating display and control movements for displays moving in the vertical or horizontal directions has been reported. Here we report effects of display movement angle, where the display moves at angles (relative to the vertical) of between 0° and 180°. The experiment used six different controls, four display locations relative to the operator and three types of indicator. Indicator types were included because of the strong effects of the 'scale-side principle' that are variable with display angle. A directional indicator had higher stereotype strength than a neutral indicator, and showed an apparent reversal in control/display stereotype direction beyond an angle of 90°. However, with a neutral indicator this control reversal was not present. Practitioner Summary: The effects of display moving at angles other than the four cardinal directions, types of control, location of display and types of indicator are investigated. Indicator types (directional and neutral) have an effect on stereotype strength and may cause an apparent control reversal with change of display movement angle.

  10. The availability of snack food displays that may trigger impulse purchases in Melbourne supermarkets

    OpenAIRE

    Thornton, Lukar E; Cameron, Adrian J; McNaughton, Sarah A; Worsley, Anthony; Crawford, David A

    2012-01-01

    Abstract Background Supermarkets play a major role in influencing the food purchasing behaviours of most households. Snack food exposures within these stores may contribute to higher levels of consumption and ultimately to increasing levels of obesity, particularly within socioeconomically disadvantaged neighbourhoods. We aimed to examine the availability of snack food displays at checkouts, end-of-aisle displays and island displays in major supermarket chains in the least and most socioecono...

  11. Computer-generated display system guidelines. Volume 2. Developing an evaluation plan

    International Nuclear Information System (INIS)

    1984-09-01

    Volume 1 of this report provides guidance to utilities on the design of displays and the selection and retrofit of a computer-generated display system in the control room of an operating nuclear power plant. Volume 2 provides guidance on planning and managing empirical evaluation of computer-generated display systems, particularly when these displays are primary elements of computer-based operator aids. The guidance provided is in terms of a multilevel evaluation methodology that enables sequential consideration of three primary issues: (1) compatibility; (2) understandability; and (3) effectiveness. The evaluation process approaches these three issues with a top-down review of system objectives, functions, tasks, and information requirements. The process then moves bottom-up from lower-level to higher-level issues, employing different evaluation methods at each level in order to maximize the efficiency and effectiveness of the evaluation process

  12. Effects of Higher and Lower Level Writing-To-Learn Assignments on Higher and Lower Level Examination Questions

    Science.gov (United States)

    Nevid, Jeffrey S.; Ambrose, Michael A.; Pyun, Yea Seul

    2017-01-01

    Our study examined whether brief writing-to-learn assignments linked to lower and higher levels in Bloom's taxonomy affected performance differentially on examination performance in assessing these skill levels. Using a quasi-random design, 91 undergraduate students in an introductory psychology class completed eight lower level and eight higher…

  13. Systems and methods for displaying data in split dimension levels

    Science.gov (United States)

    Stolte, Chris; Hanrahan, Patrick

    2015-07-28

    Systems and methods for displaying data in split dimension levels are disclosed. In some implementations, a method includes: at a computer, obtaining a dimensional hierarchy associated with a dataset, wherein the dimensional hierarchy includes at least one dimension and a sub-dimension of the at least one dimension; and populating information representing data included in the dataset into a visual table having a first axis and a second axis, wherein the first axis corresponds to the at least one dimension and the second axis corresponds to the sub-dimension of the at least one dimension.

  14. Safety parameter display systems' effect on operator performance

    International Nuclear Information System (INIS)

    Cerven, F.; Ford, R.E.; Blackman, H.S.

    1983-01-01

    Computer generated displays are a powerful and flexible tool for presenting data to the operators of nuclear power plants. Such displays are currently being developed in industry for use as safety parameter displays and for use in advanced control rooms. There exists a need for methods to objectively evaluate the effect of these displays, positive or negative, on the performance of control room personnel. Results of developing one such method, noninteractive simulation, and the two experiments that were performed to determine if it can be used as a method for evaluating computer displays are presented. This method is more objective and powerful than pencil and paper methods because it measures human performance rather than opinion or perference, has excellent control of the experimental variables, and has a higher fidelity to the control room environment. The results of these experiments indicates that the present methodology does not differentiate among the display types tested at a statistically significant level. In other words, all display types tested worked equally well in providing operators needed information

  15. DP: Parameter Display Page Program

    International Nuclear Information System (INIS)

    Anderson, M.

    1994-01-01

    The Parameter Display Page program (DP) is a Motif/X11-based program to allow easily configured, dynamic device and process variable monitoring and manipulation in the EPICS environment. DP provides a tabular data format for interactive viewing and manipulation of device and process variable statistics, as well as formatted PostScript output to files and printers. DP understands and operates in two (unfortunately disjoint at this time) namespaces in the EPICS environment ''devices'' and ''process variables''. The higher level namespace of devices includes Composite and Atomic Devices registered via the Device Access server; the lower level (flat) namespace is that of normal Process Variables accessible via Channel Access

  16. Evaluating display fidelity and interaction fidelity in a virtual reality game.

    Science.gov (United States)

    McMahan, Ryan P; Bowman, Doug A; Zielinski, David J; Brady, Rachael B

    2012-04-01

    In recent years, consumers have witnessed a technological revolution that has delivered more-realistic experiences in their own homes through high-definition, stereoscopic televisions and natural, gesture-based video game consoles. Although these experiences are more realistic, offering higher levels of fidelity, it is not clear how the increased display and interaction aspects of fidelity impact the user experience. Since immersive virtual reality (VR) allows us to achieve very high levels of fidelity, we designed and conducted a study that used a six-sided CAVE to evaluate display fidelity and interaction fidelity independently, at extremely high and low levels, for a VR first-person shooter (FPS) game. Our goal was to gain a better understanding of the effects of fidelity on the user in a complex, performance-intensive context. The results of our study indicate that both display and interaction fidelity significantly affect strategy and performance, as well as subjective judgments of presence, engagement, and usability. In particular, performance results were strongly in favor of two conditions: low-display, low-interaction fidelity (representative of traditional FPS games) and high-display, high-interaction fidelity (similar to the real world).

  17. Improvements in data display

    International Nuclear Information System (INIS)

    Ellis, G.W.

    1979-01-01

    An analog signal processor is described in this patent for connecting a source of analog signals to a cathode ray tube display in order to extend the dynamic range of the display. This has important applications in the field of computerised X-ray tomography since significant medical information, such as tumours in soft tissue, is often represented by minimal level changes in image density. Cathode ray tube displays are limited to approximately 15 intensity levels. Thus if both strong and weak absorption of the X-rays occurs, the dynamic range of the transmitted signals will be too large to permit small variations to be examined directly on a cathode ray display. Present tomographic image reconstruction methods are capable of quantising X-ray absorption density measurements into 256 or more distinct levels and a description is given of the electronics which enables the upper and lower range of intensity levels to be independently set and continuously varied. (UK)

  18. Service level status-a new real-time status display for IT services

    Energy Technology Data Exchange (ETDEWEB)

    Lopienski, S [IT Department, FIO group CERN, European Organization for Nuclear Research, 1211 Geneve 23 (Switzerland)], E-mail: Sebastian.Lopienski@cern.ch

    2008-07-15

    Nowadays, IT departments provide, and people use, computing services of an increasingly heterogeneous nature. There is thus a growing need for a status display that groups these different services and reports their status and availability in a uniform way. The Service Level Status (SLS) system addresses these needs by providing a web-based display that dynamically shows availability, basic information and statistics about various IT services, as well as the dependencies between them. This paper first introduces the requirements SLS had to meet, and the main concepts behind it, like service availability and status, Key Performance Indicators (KPIs), sub/meta-services, and service dependencies. It then describes the SLS system architecture, and some interesting implementation details, such as the usage of XML Schemas. Since clear visualization of service availability and status is one of the main goals of SLS, emphasis is put on describing the intuitive web-based user interface.

  19. Service level status-a new real-time status display for IT services

    International Nuclear Information System (INIS)

    Lopienski, S

    2008-01-01

    Nowadays, IT departments provide, and people use, computing services of an increasingly heterogeneous nature. There is thus a growing need for a status display that groups these different services and reports their status and availability in a uniform way. The Service Level Status (SLS) system addresses these needs by providing a web-based display that dynamically shows availability, basic information and statistics about various IT services, as well as the dependencies between them. This paper first introduces the requirements SLS had to meet, and the main concepts behind it, like service availability and status, Key Performance Indicators (KPIs), sub/meta-services, and service dependencies. It then describes the SLS system architecture, and some interesting implementation details, such as the usage of XML Schemas. Since clear visualization of service availability and status is one of the main goals of SLS, emphasis is put on describing the intuitive web-based user interface

  20. Displays in scintigraphy

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.E.; Pizer, S.M.

    1977-01-01

    Displays have several functions: to transmit images, to permit interaction, to quantitate features and to provide records. The main characteristics of displays used for image transmission are their resolution, dynamic range, signal-to-noise ratio and uniformity. Considerations of visual acuity suggest that the display element size should be much less than the data element size, and in current practice at least 256X256 for a gamma camera image. The dynamic range for image transmission should be such that at least 64 levels of grey (or equivalent) are displayed. Scanner displays are also considered, and in particular, the requirements of a whole-body camera are examined. A number of display systems and devices are presented including a 'new' heated object colour display system. Interaction with displays is considered, including background subtraction, contrast enhancement, position indication and region-of-interest generation. Such systems lead to methods of quantitation, which imply knowledge of the expected distributions. Methods for intercomparing displays are considered. Polaroid displays, which have for so long dominated the field, are in the process of being replaced by stored image displays, now that large cheap memories exist which give an equivalent image quality. The impact of this in nuclear medicine is yet to be seen, but a major effect will be to enable true quantitation. (author)

  1. Effect Displays in R for Generalised Linear Models

    Directory of Open Access Journals (Sweden)

    John Fox

    2003-07-01

    Full Text Available This paper describes the implementation in R of a method for tabular or graphical display of terms in a complex generalised linear model. By complex, I mean a model that contains terms related by marginality or hierarchy, such as polynomial terms, or main effects and interactions. I call these tables or graphs effect displays. Effect displays are constructed by identifying high-order terms in a generalised linear model. Fitted values under the model are computed for each such term. The lower-order "relatives" of a high-order term (e.g., main effects marginal to an interaction are absorbed into the term, allowing the predictors appearing in the high-order term to range over their values. The values of other predictors are fixed at typical values: for example, a covariate could be fixed at its mean or median, a factor at its proportional distribution in the data, or to equal proportions in its several levels. Variations of effect displays are also described, including representation of terms higher-order to any appearing in the model.

  2. The availability of snack food displays that may trigger impulse purchases in Melbourne supermarkets

    Directory of Open Access Journals (Sweden)

    Thornton Lukar E

    2012-03-01

    Full Text Available Abstract Background Supermarkets play a major role in influencing the food purchasing behaviours of most households. Snack food exposures within these stores may contribute to higher levels of consumption and ultimately to increasing levels of obesity, particularly within socioeconomically disadvantaged neighbourhoods. We aimed to examine the availability of snack food displays at checkouts, end-of-aisle displays and island displays in major supermarket chains in the least and most socioeconomically disadvantaged neighbourhoods of Melbourne. Methods Within-store audits of 35 Melbourne supermarkets. Supermarkets were sampled from the least and most socioeconomically disadvantaged suburbs within 30 km of the Melbourne CBD. We measured the availability of crisps, chocolate, confectionery, and soft drinks (diet and regular at the checkouts, in end-of-aisle displays, and in island bin displays. Results Snack food displays were most prominent at checkouts with only five stores not having snack foods at 100% of their checkouts. Snack foods were also present at a number of end-of-aisle displays (at both the front (median 38% and back (median 33% of store, and in island bin displays (median number of island displays: 7; median total circumference of island displays: 19.4 metres. Chocolate items were the most common snack food item on display. There was no difference in the availability of these snack food displays by neighbourhood disadvantage. Conclusions As a result of the high availability of snack food displays, exposure to snack foods is almost unavoidable in Melbourne supermarkets, regardless of levels of neighbourhood socioeconomic disadvantage. Results of this study could promote awareness of the prominence of unhealthy food items in chain-brand supermarkets outlets.

  3. Shape Memory Polymers Containing Higher Acrylate Content Display Increased Endothelial Cell Attachment

    Science.gov (United States)

    Govindarajan, Tina; Shandas, Robin

    2018-01-01

    Shape Memory Polymers (SMPs) are smart materials that can recall their shape upon the application of a stimulus, which makes them appealing materials for a variety of applications, especially in biomedical devices. Most prior SMP research has focused on tuning bulk properties; studying surface effects of SMPs may extend the use of these materials to blood-contacting applications, such as cardiovascular stents, where surfaces that support rapid endothelialization have been correlated to stent success. Here, we evaluate endothelial attachment onto the surfaces of a family of SMPs previously developed in our group that have shown promise for biomedical devices. Nine SMP formulations containing varying amounts of tert-Butyl acrylate (tBA) and Poly(ethylene glycol) dimethacrylate (PEGDMA) were analyzed for endothelial cell attachment. Dynamic mechanical analysis (DMA), contact angle studies, and atomic force microscopy (AFM) were used to verify bulk and surface properties of the SMPs. Human umbilical vein endothelial cell (HUVEC) attachment and viability was verified using fluorescent methods. Endothelial cells preferentially attached to SMPs with higher tBA content, which have rougher, more hydrophobic surfaces. HUVECs also displayed an increased metabolic activity on these high tBA SMPs over the course of the study. This class of SMPs may be promising candidates for next generation blood-contacting devices. PMID:29707382

  4. Shape Memory Polymers Containing Higher Acrylate Content Display Increased Endothelial Cell Attachment

    Directory of Open Access Journals (Sweden)

    Tina Govindarajan

    2017-11-01

    Full Text Available Shape Memory Polymers (SMPs are smart materials that can recall their shape upon the application of a stimulus, which makes them appealing materials for a variety of applications, especially in biomedical devices. Most prior SMP research has focused on tuning bulk properties; studying surface effects of SMPs may extend the use of these materials to blood-contacting applications, such as cardiovascular stents, where surfaces that support rapid endothelialization have been correlated to stent success. Here, we evaluate endothelial attachment onto the surfaces of a family of SMPs previously developed in our group that have shown promise for biomedical devices. Nine SMP formulations containing varying amounts of tert-Butyl acrylate (tBA and Poly(ethylene glycol dimethacrylate (PEGDMA were analyzed for endothelial cell attachment. Dynamic mechanical analysis (DMA, contact angle studies, and atomic force microscopy (AFM were used to verify bulk and surface properties of the SMPs. Human umbilical vein endothelial cell (HUVEC attachment and viability was verified using fluorescent methods. Endothelial cells preferentially attached to SMPs with higher tBA content, which have rougher, more hydrophobic surfaces. HUVECs also displayed an increased metabolic activity on these high tBA SMPs over the course of the study. This class of SMPs may be promising candidates for next generation blood-contacting devices.

  5. Ocular Tolerance of Contemporary Electronic Display Devices.

    Science.gov (United States)

    Clark, Andrew J; Yang, Paul; Khaderi, Khizer R; Moshfeghi, Andrew A

    2018-05-01

    Electronic displays have become an integral part of life in the developed world since the revolution of mobile computing a decade ago. With the release of multiple consumer-grade virtual reality (VR) and augmented reality (AR) products in the past 2 years utilizing head-mounted displays (HMDs), as well as the development of low-cost, smartphone-based HMDs, the ability to intimately interact with electronic screens is greater than ever. VR/AR HMDs also place the display at much closer ocular proximity than traditional electronic devices while also isolating the user from the ambient environment to create a "closed" system between the user's eyes and the display. Whether the increased interaction with these devices places the user's retina at higher risk of damage is currently unclear. Herein, the authors review the discovery of photochemical damage of the retina from visible light as well as summarize relevant clinical and preclinical data regarding the influence of modern display devices on retinal health. Multiple preclinical studies have been performed with modern light-emitting diode technology demonstrating damage to the retina at modest exposure levels, particularly from blue-light wavelengths. Unfortunately, high-quality in-human studies are lacking, and the small clinical investigations performed to date have failed to keep pace with the rapid evolutions in display technology. Clinical investigations assessing the effect of HMDs on human retinal function are also yet to be performed. From the available data, modern consumer electronic displays do not appear to pose any acute risk to vision with average use; however, future studies with well-defined clinical outcomes and illuminance metrics are needed to better understand the long-term risks of cumulative exposure to electronic displays in general and with "closed" VR/AR HMDs in particular. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:346-354.]. Copyright 2018, SLACK Incorporated.

  6. Display rules versus display autonomy: emotion regulation, emotional exhaustion, and task performance in a call center simulation.

    Science.gov (United States)

    Goldberg, Lori Sideman; Grandey, Alicia A

    2007-07-01

    "Service with a smile" is satisfying for the customer, but such display rules may be costly to the employee and the organization. Most previous research on such costs has used self-reported and cross-sectional designs. The authors use an experimental approach to test tenets of resource depletion theories; specifically, whether the self-regulation of emotions required by display rules depletes energy and attentional resources during a service encounter. Using a call center simulation with three "customer" interactions, the authors found that participants given positive display rules (e.g., be enthusiastic and hide frustration) reported more postsimulation exhaustion and made more errors on the order form compared to those with display autonomy. Customer hostility during one of the calls also increased exhaustion overall and the number of errors during that specific call, though proposed interactions with display rules were not supported. Surface-level emotion regulation, but not deep-level, was the mechanism for the energy depletion effect of display rules, while display rules had a direct effect on performance decrements. Theoretical and practical implications for display rules as part of job requirements are discussed. Copyright 2007 APA

  7. Development and evaluation of a method of calibrating medical displays based on fixed adaptation

    Energy Technology Data Exchange (ETDEWEB)

    Sund, Patrik, E-mail: patrik.sund@vgregion.se; Månsson, Lars Gunnar; Båth, Magnus [Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg SE-41345, Sweden and Department of Radiation Physics, University of Gothenburg, Gothenburg SE-41345 (Sweden)

    2015-04-15

    Purpose: The purpose of this work was to develop and evaluate a new method for calibration of medical displays that includes the effect of fixed adaptation and by using equipment and luminance levels typical for a modern radiology department. Methods: Low contrast sinusoidal test patterns were derived at nine luminance levels from 2 to 600 cd/m{sup 2} and used in a two alternative forced choice observer study, where the adaptation level was fixed at the logarithmic average of 35 cd/m{sup 2}. The contrast sensitivity at each luminance level was derived by establishing a linear relationship between the ten pattern contrast levels used at every luminance level and a detectability index (d′) calculated from the fraction of correct responses. A Gaussian function was fitted to the data and normalized to the adaptation level. The corresponding equation was used in a display calibration method that included the grayscale standard display function (GSDF) but compensated for fixed adaptation. In the evaluation study, the contrast of circular objects with a fixed pixel contrast was displayed using both calibration methods and was rated on a five-grade scale. Results were calculated using a visual grading characteristics method. Error estimations in both observer studies were derived using a bootstrap method. Results: The contrast sensitivities for the darkest and brightest patterns compared to the contrast sensitivity at the adaptation luminance were 37% and 56%, respectively. The obtained Gaussian fit corresponded well with similar studies. The evaluation study showed a higher degree of equally distributed contrast throughout the luminance range with the calibration method compensated for fixed adaptation than for the GSDF. The two lowest scores for the GSDF were obtained for the darkest and brightest patterns. These scores were significantly lower than the lowest score obtained for the compensated GSDF. For the GSDF, the scores for all luminance levels were statistically

  8. Children's Control/Display Stereotypes.

    Science.gov (United States)

    Hoffmann, Errol R; Chan, Alan H S; Tai, Judy P C

    2018-06-01

    Objective The aim of this study was to determine control/display stereotypes for children of a range of ages and development of these stereotypes with age. Background Little is known about control/display stereotypes for children of different ages and the way in which these stereotypes develop with age. This study is part of a program to determine the need to design differentially for these age groups. Method We tested four groups of children with various tasks (age groups 5 to 7, 8 to 10, 11 to 13, 14 to 16), with about 30 in each group. Examples of common tasks were opening a bottle, turning on taps, and allocating numbers to keypads. More complex tasks involved rotating a control to move a display in a requested direction. Results Tasks with which different age groups were familiar showed no effect of age group. Different control/display arrangements generally showed an increase in stereotype strength with age, with dependence on the form of the control/display arrangement. Two-dimensional arrangements, with the control on the same plane as the display, had higher stereotype strength than three-dimensional arrangements for all age groups, suggesting an effect of familiarity with controls and displays with increasing age. Conclusion Children's control/display stereotypes do not differ greatly from those of adults, and hence, design for children older than 5 years of age, for control/display stereotypes, can be the same as that for adult populations. Application When designing devices for children, the relationship between controls and displays can be as for adult populations, for which there are considerable experimental data.

  9. A nanobody:GFP bacterial platform that enables functional enzyme display and easy quantification of display capacity.

    Science.gov (United States)

    Wendel, Sofie; Fischer, Emil C; Martínez, Virginia; Seppälä, Susanna; Nørholm, Morten H H

    2016-05-03

    Bacterial surface display is an attractive technique for the production of cell-anchored, functional proteins and engineering of whole-cell catalysts. Although various outer membrane proteins have been used for surface display, an easy and versatile high-throughput-compatible assay for evaluating and developing surface display systems is missing. Using a single domain antibody (also called nanobody) with high affinity for green fluorescent protein (GFP), we constructed a system that allows for fast, fluorescence-based detection of displayed proteins. The outer membrane hybrid protein LppOmpA and the autotransporter C-IgAP exposed the nanobody on the surface of Escherichia coli with very different efficiency. Both anchors were capable of functionally displaying the enzyme Chitinase A as a fusion with the nanobody, and this considerably increased expression levels compared to displaying the nanobody alone. We used flow cytometry to analyse display capability on single-cell versus population level and found that the signal peptide of the anchor has great effect on display efficiency. We have developed an inexpensive and easy read-out assay for surface display using nanobody:GFP interactions. The assay is compatible with the most common fluorescence detection methods, including multi-well plate whole-cell fluorescence detection, SDS-PAGE in-gel fluorescence, microscopy and flow cytometry. We anticipate that the platform will facilitate future in-depth studies on the mechanism of protein transport to the surface of living cells, as well as the optimisation of applications in industrial biotech.

  10. X-Windows Widget for Image Display

    Science.gov (United States)

    Deen, Robert G.

    2011-01-01

    XvicImage is a high-performance XWindows (Motif-compliant) user interface widget for displaying images. It handles all aspects of low-level image display. The fully Motif-compliant image display widget handles the following tasks: (1) Image display, including dithering as needed (2) Zoom (3) Pan (4) Stretch (contrast enhancement, via lookup table) (5) Display of single-band or color data (6) Display of non-byte data (ints, floats) (7) Pseudocolor display (8) Full overlay support (drawing graphics on image) (9) Mouse-based panning (10) Cursor handling, shaping, and planting (disconnecting cursor from mouse) (11) Support for all user interaction events (passed to application) (12) Background loading and display of images (doesn't freeze the GUI) (13) Tiling of images.

  11. Software for graphic display systems

    International Nuclear Information System (INIS)

    Karlov, A.A.

    1978-01-01

    In this paper some aspects of graphic display systems are discussed. The design of a display subroutine library is described, with an example, and graphic dialogue software is considered primarily from the point of view of the programmer who uses a high-level language. (Auth.)

  12. Clinical evaluation of a medical high dynamic range display

    International Nuclear Information System (INIS)

    Marchessoux, Cedric; Paepe, Lode de; Vanovermeire, Olivier; Albani, Luigi

    2016-01-01

    Purpose: Recent new medical displays do have higher contrast and higher luminance but do not have a High Dynamic Range (HDR). HDR implies a minimum luminance value close to zero. A medical HDR display prototype based on two Liquid Crystal layers has been developed. The goal of this study is to evaluate the potential clinical benefit of such display in comparison with a low dynamic range (LDR) display. Methods: The study evaluated the clinical performance of the displays in a search and detection task. Eight radiologists read chest x-ray images some of which contained simulated lung nodules. The study used a JAFROC (Jacknife Free Receiver Operating Characteristic) approach for analyzing FROC data. The calculated figure of merit (FoM) is the probability that a lesion is rated higher than all rated nonlesions on all images. Time per case and accuracy for locating the center of the nodules were also compared. The nodules were simulated using Samei’s model. 214 CR and DR images [half were “healthy images” (chest nodule-free) and half “diseased images”] were used resulting in a total number of nodules equal to 199 with 25 images with 1 nodule, 51 images with 2 nodules, and 24 images with 3 nodules. A dedicated software interface was designed for visualizing the images for each session. For the JAFROC1 statistical analysis, the study is done per nodule category: all nodules, difficult nodules, and very difficult nodules. Results: For all nodules, the averaged FoM HDR is slightly higher than FoM LDR with 0.09% of difference. For the difficult nodules, the averaged FoM HDR is slightly higher than FoM LDR with 1.38% of difference. The averaged FoM HDR is slightly higher than FoM LDR with 0.71% of difference. For the true positive fraction (TPF), both displays (the HDR and the LDR ones) have similar TPF for all nodules, but looking at difficult and very difficult nodules, there are more TP for the HDR display. The true positive fraction has been also computed in

  13. A virtual image chain for perceived image quality of medical display

    Science.gov (United States)

    Marchessoux, Cédric; Jung, Jürgen

    2006-03-01

    This paper describes a virtual image chain for medical display (project VICTOR: granted in the 5th framework program by European commission). The chain starts from raw data of an image digitizer (CR, DR) or synthetic patterns and covers image enhancement (MUSICA by Agfa) and both display possibilities, hardcopy (film on viewing box) and softcopy (monitor). Key feature of the chain is a complete image wise approach. A first prototype is implemented in an object-oriented software platform. The display chain consists of several modules. Raw images are either taken from scanners (CR-DR) or from a pattern generator, in which characteristics of DR- CR systems are introduced by their MTF and their dose-dependent Poisson noise. The image undergoes image enhancement and comes to display. For soft display, color and monochrome monitors are used in the simulation. The image is down-sampled. The non-linear response of a color monitor is taken into account by the GOG or S-curve model, whereas the Standard Gray-Scale-Display-Function (DICOM) is used for monochrome display. The MTF of the monitor is applied on the image in intensity levels. For hardcopy display, the combination of film, printer, lightbox and viewing condition is modeled. The image is up-sampled and the DICOM-GSDF or a Kanamori Look-Up-Table is applied. An anisotropic model for the MTF of the printer is applied on the image in intensity levels. The density-dependent color (XYZ) of the hardcopy film is introduced by Look-Up-tables. Finally a Human Visual System Model is applied to the intensity images (XYZ in terms of cd/m2) in order to eliminate nonvisible differences. Comparison leads to visible differences, which are quantified by higher order image quality metrics. A specific image viewer is used for the visualization of the intensity image and the visual difference maps.

  14. Modeling the leakage of LCD displays with local backlight for quality assessment

    DEFF Research Database (Denmark)

    Mantel, Claire; Korhonen, Jari; Pedersen, Jesper M.

    2014-01-01

    The recent technique of local backlight dimming has a significant impact on the quality of images displayed with a LCD screen with LED local dimming. Therefore it represents a necessary step in the quality assessment chain, independently from the other processes applied to images. This paper...... investigates the modeling of one of the major spatial artifacts produced by local dimming: leakage. Leakage appears in dark areas when the backlight level is too high for LC cells to block sufficiently and the final displayed brightness is higher than it should. A subjective quality experiment was run...... on videos displayed on LCD TV with local backlight dimming viewed from a 0° and 15° angles. The subjective results are then compared objective data using different leakage models: constant over the whole display or horizontally varying and three leakage factor (no leakage, measured at 0° and 15...

  15. Digital image display system for emergency room

    International Nuclear Information System (INIS)

    Murry, R.C.; Lane, T.J.; Miax, L.S.

    1989-01-01

    This paper reports on a digital image display system for the emergency room (ER) in a major trauma hospital. Its objective is to reduce radiographic image delivery time to a busy ER while simultaneously providing a multimodality capability. Image storage, retrieval, and display will also be facilitated with this system. The system's backbone is a token-ring network of RISC and personal computers. The display terminals are higher- function RISC computers with 1,024 2 color or gray-scale monitors. The PCs serve as administrative terminals. Nuclear medicine, CT, MR, and digitized film images are transferred to the image display system

  16. A nanobody:GFP bacterial platform that enables functional enzyme display and easy quantification of display capacity

    DEFF Research Database (Denmark)

    Wendel, Sofie; Christian Fischer, Emil; Martinez, Virginia

    2016-01-01

    Background: Bacterial surface display is an attractive technique for the production of cell-anchored, functional proteins and engineering of whole-cell catalysts. Although various outer membrane proteins have been used for surface display, an easy and versatile high-throughput-compatible assay...... to displaying the nanobody alone. We used flow cytometry to analyse display capability on single-cell versus population level and found that the signal peptide of the anchor has great effect on display efficiency.Conclusions: We have developed an inexpensive and easy read-out assay for surface display using...... nanobody: GFP interactions. The assay is compatible with the most common fluorescence detection methods, including multi-well plate whole-cell fluorescence detection, SDS-PAGE in-gel fluorescence, microscopy and flow cytometry. We anticipate that the platform will facilitate future in-depth studies...

  17. Aortic Baroreceptors Display Higher Mechanosensitivity than Carotid Baroreceptors

    Directory of Open Access Journals (Sweden)

    Eva On-Chai Lau

    2016-08-01

    Full Text Available Arterial baroreceptors are mechanical sensors that detect blood pressure changes. It has long been suggested that the two arterial baroreceptors, aortic and carotid baroreceptors, have different pressure sensitivities. However, there is no consensus as to which of the arterial baroreceptors are more sensitive to changes in blood pressure. In the present study, we employed independent methods to compare the pressure sensitivity of the two arterial baroreceptors. Firstly, pressure-activated action potential firing was measured by whole-cell current clamp with a high-speed pressure clamp system in primary cultured baroreceptor neurons. The results show that aortic depressor neurons possessed a higher percentage of mechano-sensitive neurons. Furthermore, aortic baroreceptor neurons show a lower pressure threshold than that of carotid baroreceptor neurons. Secondly, uniaxial stretching of baroreceptor neurons, that mimics the forces exerted on blood vessels, elicited a larger increase in intracellular Ca2+ rise in aortic baroreceptor neurons than in carotid baroreceptor neurons. Thirdly, the pressure-induced action potential firing in the aortic depressor nerve recorded in vivo was also higher. The present study therefore provides for a basic physiological understanding on the pressure sensitivity of the two baroreceptor neurons and suggests that aortic baroreceptors have a higher pressure sensitivity than carotid baroreceptors.

  18. Evaluating stereoscopic displays: both efficiency measures and perceived workload sensitive to manipulations in binocular disparity

    Science.gov (United States)

    van Beurden, Maurice H. P. H.; Ijsselsteijn, Wijnand A.; de Kort, Yvonne A. W.

    2011-03-01

    Stereoscopic displays are known to offer a number of key advantages in visualizing complex 3D structures or datasets. The large majority of studies that focus on evaluating stereoscopic displays for professional applications use completion time and/or the percentage of correct answers to measure potential performance advantages. However, completion time and accuracy may not fully reflect all the benefits of stereoscopic displays. In this paper, we argue that perceived workload is an additional valuable indicator reflecting the extent to which users can benefit from using stereoscopic displays. We performed an experiment in which participants were asked to perform a visual path-tracing task within a convoluted 3D wireframe structure, varying in level of complexity of the visualised structure and level of disparity of the visualisation. The results showed that an optimal performance (completion time, accuracy and workload), depend both on task difficulty and disparity level. Stereoscopic disparity revealed a faster and more accurate task performance, whereas we observed a trend that performance on difficult tasks stands to benefit more from higher levels of disparity than performance on easy tasks. Perceived workload (as measured using the NASA-TLX) showed a similar response pattern, providing evidence that perceived workload is sensitive to variations in disparity as well as task difficulty. This suggests that perceived workload could be a useful concept, in addition to standard performance indicators, in characterising and measuring human performance advantages when using stereoscopic displays.

  19. Radio frequency plasma nitriding of aluminium at higher power levels

    International Nuclear Information System (INIS)

    Gredelj, Sabina; Kumar, Sunil; Gerson, Andrea R.; Cavallaro, Giuseppe P.

    2006-01-01

    Nitriding of aluminium 2011 using a radio frequency plasma at higher power levels (500 and 700 W) and lower substrate temperature (500 deg. C) resulted in higher AlN/Al 2 O 3 ratios than obtained at 100 W and 575 deg. C. AlN/Al 2 O 3 ratios derived from X-ray photoelectron spectroscopic analysis (and corroborated by heavy ion elastic recoil time of flight spectrometry) for treatments preformed at 100 (575 deg. C), 500 (500 deg. C) and 700 W (500 deg. C) were 1.0, 1.5 and 3.3, respectively. Scanning electron microscopy revealed that plasma nitrided surfaces obtained at higher power levels exhibited much finer nodular morphology than obtained at 100 W

  20. Assessing the Need for Higher Levels of Care Among Problem Gambling Outpatients.

    Science.gov (United States)

    Ledgerwood, David M; Arfken, Cynthia L

    2017-12-01

    Most treatment for gambling disorder is provided on an outpatient basis. Only a small number of jurisdictions in North America provide higher levels of gambling treatment, such as residential or intensive outpatient (IOP) care, despite the potential need for these services. Further, there appear to be few guidelines for determining appropriate level of gambling treatment. The aim of the present study was to assess the appropriateness of higher levels of problem gambling care among clients receiving outpatient treatment. Problem gamblers and their therapists independently completed questionnaires that assessed the need and desire for residential and IOP treatment. About 42% of problem gambling outpatients noted that they would be "probably" or "definitely" willing to attend residential treatment, and about half indicated they would be equally likely to attend IOP. Therapists recommended about a third of their clients as appropriate for higher levels of care. For both client and therapist assessments, there was a significant association between desire or recommendation for level of treatment and severity of gambling and co-occurring problems. Further, therapist recommendations for level of care were significantly associated with client willingness to attend higher levels of treatment. Our data reveal the potential need for higher levels of care for problem gambling, as evaluated by clients and their therapists. Policy implications for the funding of residential and IOP treatment are discussed.

  1. An Abstraction Hierarchy based mobile PC display design in NPP maintenance considering the level of expertise

    International Nuclear Information System (INIS)

    Yim, Ho Bin; Kim, In; Seong, Poong Hyun

    2011-01-01

    Research highlights: → Six levels of Abstraction Hierarchy based information for maintenance were proposed. → Errors and workload with AH based information display were reduced for LL subjects. → Design concerns discovered can be applied to practical use of mobile maintenance aids. - Abstract: Recently, the importance of effective maintenance in nuclear power plants (NPPs) has been emphasized and research into effective maintenance by adopting mobile maintenance aids (MMAs) have been attempted. For improved and effective use of an MMA display design method based on the hierarchy is proposed and its design considerations are discussed in this study. Six levels of hierarchy are proposed in this paper to classify the maintenance information. By classifying and organizing maintenance information using the hierarchy, maintenance information can be used effectively by users with either high or low levels of expertise. When information classification has been finished, the information for MMA design is selected and designed. With the considerations of MMA design analysis and guidelines, a hierarchy-based MMA is designed for the maintenance tasks. An experiment is conducted using the hierarchy-based MMA in order to estimate the effectiveness of the proposed method for the maintenance tasks and to identify design considerations to enhance the proposed MMAs. The result indicated that a hierarchy-based manual was more effective than a conventional manual in terms of task completion time and number of errors. The workload for the hierarchy-based manual was estimated less than the conventional manual for subjects with low level of expertise. As the level of expertise increases, subjects tended to follow more abstract information while the number of navigations decreased. It is believed that when mobile devices become pervasive in NPP maintenance fields, the hierarchy model applied MMAs can be used as an effective maintenance supporting tool.

  2. Characterisation of particulate exposure during fireworks displays

    Science.gov (United States)

    Joly, Alexandre; Smargiassi, Audrey; Kosatsky, Tom; Fournier, Michel; Dabek-Zlotorzynska, Ewa; Celo, Valbona; Mathieu, David; Servranckx, René; D'amours, Réal; Malo, Alain; Brook, Jeffrey

    2010-11-01

    Little is known about the level and content of exposure to fine particles (PM 2.5) among persons who attend fireworks displays and those who live nearby. An evaluation of the levels of PM 2.5 and their elemental content was carried out during the nine launches of the 2007 Montréal International Fireworks Competition. For each event, a prediction of the location of the firework plume was obtained from the Canadian Meteorological Centre (CMC) of the Meteorological Service of Canada. PM 2.5 was measured continuously with a photometer (Sidepak™, TSI) within the predicted plume location ("predicted sites"), and integrated samples were collected using portable personal samplers. An additional sampler was located on a nearby roof ("fixed site"). The elemental composition of the collected PM 2.5 samples from the "predicted sites" was determined using both a non-destructive energy dispersive ED-XRF method and an ICP-MS method with a near-total microwave-assisted acid digestion. The elemental composition of the "fixed site" samples was determined by the ICP-MS with the near-total digestion method. The highest PM 2.5 levels reached nearly 10 000 μg m -3, roughly 1000 times background levels. Elements such as K, Cl, Al, Mg and Ti were markedly higher in plume-exposed filters. This study shows that 1) persons in the plume and in close proximity to the launch site may be exposed to extremely high levels of PM 2.5 for the duration of the display and, 2) that the plume contains specific elements for which little is known of their acute cardio-respiratory toxicity.

  3. Wafer-level vacuum packaged resonant micro-scanning mirrors for compact laser projection displays

    Science.gov (United States)

    Hofmann, Ulrich; Oldsen, Marten; Quenzer, Hans-Joachim; Janes, Joachim; Heller, Martin; Weiss, Manfred; Fakas, Georgios; Ratzmann, Lars; Marchetti, Eleonora; D'Ascoli, Francesco; Melani, Massimiliano; Bacciarelli, Luca; Volpi, Emilio; Battini, Francesco; Mostardini, Luca; Sechi, Francesco; De Marinis, Marco; Wagner, Bernd

    2008-02-01

    Scanning laser projection using resonant actuated MEMS scanning mirrors is expected to overcome the current limitation of small display size of mobile devices like cell phones, digital cameras and PDAs. Recent progress in the development of compact modulated RGB laser sources enables to set up very small laser projection systems that become attractive not only for consumer products but also for automotive applications like head-up and dash-board displays. Within the last years continuous progress was made in increasing MEMS scanner performance. However, only little is reported on how mass-produceability of these devices and stable functionality even under harsh environmental conditions can be guaranteed. Automotive application requires stable MEMS scanner operation over a wide temperature range from -40° to +85°Celsius. Therefore, hermetic packaging of electrostatically actuated MEMS scanning mirrors becomes essential to protect the sensitive device against particle contamination and condensing moisture. This paper reports on design, fabrication and test of a resonant actuated two-dimensional micro scanning mirror that is hermetically sealed on wafer level. With resonant frequencies of 30kHz and 1kHz, an achievable Theta-D-product of 13mm.deg and low dynamic deformation <20nm RMS it targets Lissajous projection with SVGA-resolution. Inevitable reflexes at the vacuum package surface can be seperated from the projection field by permanent inclination of the micromirror.

  4. Low contrast detectability for color patterns variation of display images

    International Nuclear Information System (INIS)

    Ogura, Akio

    1998-01-01

    In recent years, the radionuclide images are acquired in digital form and displayed with false colors for signal intensity. This color scales for signal intensity have various patterns. In this study, low contrast detectability was compared the performance of gray scale cording with three color scales: the hot color scale, prism color scale and stripe color scale. SPECT images of brain phantom were displayed using four color patterns. These printed images and display images were evaluated with ROC analysis. Display images were indicated higher detectability than printed images. The hot scale and gray scale images indicated better Az of ROC than prism scale images because the prism scale images showed higher false positive rate. (author)

  5. Digital Display Integration Project Project Online 2.0

    International Nuclear Information System (INIS)

    Bardsley, J. N.

    1999-01-01

    The electronic display industry is changing in three important ways. First, the dominance of the cathode ray tube (CRT) is being challenged by the development of flat panel displays (FPDs). This will lead to the availability of displays of higher performance, albeit at greater cost. Secondly, the analog interfaces between displays that show data and the computers that generate the data are being replaced by digital connections. Finally, a high-resolution display is becoming the most expensive component in computer system for homes and small offices. It is therefore desirable that the useful lifetime of the display extend over several years and that the electronics allows the display to be used with many different image sources. Hopefully, the necessity of having three or four large CRTs in one office to accommodate different computer operating systems or communication protocols will soon disappear. Instead, we hope to see a set of flat panels that can be switched to show several independent images from multiple sources or a composite image from a single source. The more rapid rate of technological improvements and the higher cost of flat panel displays raise the incentive for greater planning and guidance in the acquisition and integration of high performance displays into large organizations, such as LLNL. The goal of the Digital Display Integration Project (DDIP) is to provide such support. This will be achieved through collaboration with leading suppliers of displays, communications equipment and image-processing products, and by greater exchange of information within the Laboratory. The project will start in October 1999. During the first two years (FY2000-1), the primary focus of the program will be upon: introducing displays with high information content (over 5M pixels); facilitating the transition from analog to digital interfaces; enabling data transfer from key computer platforms; incorporating optical communications to remove length restrictions on data

  6. Display of nuclear medicine imaging studies

    International Nuclear Information System (INIS)

    Singh, B.; Kataria, S.K.; Samuel, A.M.

    2002-08-01

    Nuclear medicine imaging studies involve evaluation of a large amount of image data. Digital signal processing techniques have introduced processing algorithms that increase the information content of the display. Nuclear medicine imaging studies require interactive selection of suitable form of display and pre-display processing. Static imaging study requires pre-display processing to detect focal defects. Point operations (histogram modification) along with zoom and capability to display more than one image in one screen is essential. This album mode of display is also applicable to dynamic, MUGA and SPECT data. Isometric display or 3-D graph of the image data is helpful in some cases e.g. point spread function, flood field data. Cine display is used on a sequence of images e.g. dynamic, MUGA and SPECT imaging studies -to assess the spatial movement of tracer with time. Following methods are used at the investigator's discretion for inspection of the 3-D object. 1) Display of orthogonal projections, 2) Display of album of user selected coronal/ sagital/ transverse orthogonal slices, 3) Display of three orthogonal slices through user selected point, 4) Display of a set of orthogonal slices generated in the user-selected volume, 5) Generation and display of 3-D shaded surface. 6) Generation of volume data and display along with the 3-D shaded surface, 7) Side by side display orthogonal slices of two 3-D objects. Displaying a set of two-dimensional slices of a 3-D reconstructed object through shows all the defects but lacks the 3-D perspective. Display of shaded surface lacks the ability to show the embedded defects. Volume display -combining the 3-D surface and gray level volume data is perhaps the best form of display. This report describes these forms of display along with the theory. (author)

  7. New ultraportable display technology and applications

    Science.gov (United States)

    Alvelda, Phillip; Lewis, Nancy D.

    1998-08-01

    MicroDisplay devices are based on a combination of technologies rooted in the extreme integration capability of conventionally fabricated CMOS active-matrix liquid crystal display substrates. Customized diffraction grating and optical distortion correction technology for lens-system compensation allow the elimination of many lenses and systems-level components. The MicroDisplay Corporation's miniature integrated information display technology is rapidly leading to many new defense and commercial applications. There are no moving parts in MicroDisplay substrates, and the fabrication of the color generating gratings, already part of the CMOS circuit fabrication process, is effectively cost and manufacturing process-free. The entire suite of the MicroDisplay Corporation's technologies was devised to create a line of application- specific integrated circuit single-chip display systems with integrated computing, memory, and communication circuitry. Next-generation portable communication, computer, and consumer electronic devices such as truly portable monitor and TV projectors, eyeglass and head mounted displays, pagers and Personal Communication Services hand-sets, and wristwatch-mounted video phones are among the may target commercial markets for MicroDisplay technology. Defense applications range from Maintenance and Repair support, to night-vision systems, to portable projectors for mobile command and control centers.

  8. Unit information system operational displays for VVER-1000 reactors

    International Nuclear Information System (INIS)

    Anikanov, S.S.; Carrera, J.P.; Gordon, P.

    1997-01-01

    The role of high level operational displays is explained as well as the principles of the design of such displays. The tasks of WWER operating personnel are described and the support provided by operational displays is highlighted. The architecture of the displays is also dealt with. (A.K.)

  9. Modification of booming level for higher correlation with booming sensation; Booming level no koseidoka

    Energy Technology Data Exchange (ETDEWEB)

    Hatano, S; Hashimoto, T [Seikei University, Tokyo (Japan)

    1997-10-01

    In our previous study, we proposed a objective measure, i.e., Booming Level for quantifying booming sensation caused by car interior noise. In this paper, Booming Level was modified with its weighting function and within the process of calculation 1/3 octave band level was modified for the best match with subjective result. These modifications were conducted through a subjective experiment rating booming sensation with sounds having much lower frequency contents below 63Hz. With this modified Booming Level, we have obtained higher correlation for rating booming sensation with sounds having prominent low frequency components. 1 ref., 10 figs.

  10. Design and Evaluation of a Thermal Tactile Display for Colour Rendering

    Directory of Open Access Journals (Sweden)

    Zhen Jia

    2015-11-01

    Full Text Available This paper proposes a novel method of manipulating both thermal change rate and thermal intensity to convey colour information by using a thermal tactile display. The colour-space transformation from {red, green, blue} to {hue, saturation, intensity} is introduced, and the mapping between colour and temperature is established based on warm and cold colours. Considering the lower resolution of the tactile channel, six limited stimulation levels are generated to represent colours. Based on the semi-infinite body model, the thermal response within the skin for each stimulation form is investigated. The Peltier element of the display is designed to convey different thermal stimuli to the human finger. Two experiments are performed to evaluate the performance of the display: colour identification and discrimination. Experimental results indicate that there is a response bias among the perceived colours for the traditional method of only employing thermal intensity, but there is no response bias for the proposed method; subjects’ mean recognition accuracy with the proposed method is significantly higher than that gained using the traditional method. Furthermore, colour information of the captured images can be reliably discriminated by using this devised thermal tactile display.

  11. Effect of price display on brand luxury perceptions

    OpenAIRE

    Parguel , Béatrice; Delécolle , Thierry; Valette-Florence , Pierre

    2014-01-01

    Based on two experimental studies, this paper investigates the impact of price display in the luxury sector on perceived brand luxury and brand attitude. Using a sample of students, Study1 shows that price display is associated with higher perceived quality, uniqueness, and conspicuousness for a fictitious luxury brand presented in a store window. Using two real luxury brands and a larger sample of consumers, Study 2 confirms the positive effect of price display on the brand’s perceived consp...

  12. Characterizing the reflectivity of handheld display devices.

    Science.gov (United States)

    Liu, Peter; Badano, Aldo

    2014-08-01

    With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using methods recommended by the American Association of Physicists in Medicine Task Group 18 (TG18). The authors modified the diffuse reflectance coefficient measurement method outlined in the TG18 report. The authors measured seven handheld display devices (two phones and five tablets) and three workstation displays. The device was attached to a black panel with Velcro. To study the effect of the back surface on the diffuse reflectance coefficient, the authors created Styrofoam masks with different size square openings and placed it in front of the device. Overall, for each display device, measurements of illuminance and reflected luminance on the display screen were taken. The authors measured with no mask, with masks of varying size, and with display-size masks, and calculated the corresponding diffuse reflectance coefficient. For all handhelds, the diffuse reflectance coefficient measured with no back panel were lower than measurements performed with a mask. The authors found an overall increase in reflectivity as the size of the mask decreases. For workstations displays, diffuse reflectance coefficients were higher when no back panel was used, and higher than with masks. In all cases, as luminance increased, illuminance increased, but not at the same rate. Since the size of handheld displays is smaller than that of workstation devices, the TG18 method suffers from a dependency on illumination condition. The authors show that the diffuse reflection coefficients can vary depending on the nature of the back surface of the illuminating box. The variability in the diffuse coefficient can be as large as 20% depending on the size of the mask. For all measurements

  13. Electron-positron annihilation into hadrons at the higher-loop levels

    Energy Technology Data Exchange (ETDEWEB)

    Nesterenko, A.V. [Joint Institute for Nuclear Research, Bogoliubov Laboratory of Theoretical Physics, Dubna (Russian Federation)

    2017-12-15

    The strong corrections to the R-ratio of electron-positron annihilation into hadrons are studied at the higher-loop levels. Specifically, the derivation of a general form of the commonly employed approximate expression for the R-ratio (which constitutes its truncated re-expansion at high energies) is delineated, the appearance of the pertinent π{sup 2}-terms is expounded, and their basic features are examined. It is demonstrated that the validity range of such approximation is strictly limited to √(s)/Λ > exp(π/2) ≅ 4.81 and that it converges rather slowly when the energy scale approaches this value. The spectral function required for the proper calculation of the R-ratio is explicitly derived and its properties at the higher-loop levels are studied. The developed method of calculation of the spectral function enables one to obtain the explicit expression for the latter at an arbitrary loop level. By making use of the derived spectral function the proper expression for the R-ratio is calculated up to the five-loop level and its properties are examined. It is shown that the loop convergence of the proper expression for the R-ratio is better than that of its commonly employed approximation. The impact of the omitted higher-order π{sup 2}-terms on the latter is also discussed. (orig.)

  14. Dimensions of Situatedness for Digital Public Displays

    Directory of Open Access Journals (Sweden)

    Rui José

    2014-01-01

    Full Text Available Public displays are often strongly situated signs deeply embedded in their physical, social, and cultural setting. Understanding how the display is coupled with on-going situations, its level of situatedness, provides a key element for the interpretation of the displays themselves but is also an element for the interpretation of place, its situated practices, and its social context. Most digital displays, however, do not achieve the same sense of situatedness that seems so natural in their nondigital counterparts. This paper investigates people’s perception of situatedness when considering the connection between public displays and their context. We have collected over 300 photos of displays and conducted a set of analysis tasks involving focus groups and structured interviews with 15 participants. The contribution is a consolidated list of situatedness dimensions that should provide a valuable resource for reasoning about situatedness in digital displays and informing the design and development of display systems.

  15. Effects of Viewing Displays from Different Distances on Human Visual System

    Directory of Open Access Journals (Sweden)

    Mohamed Z. Ramadan

    2017-11-01

    Full Text Available The current stereoscopic 3D displays have several human-factor issues including visual-fatigue symptoms such as eyestrain, headache, fatigue, nausea, and malaise. The viewing time and viewing distance are factors that considerably affect the visual fatigue associated with 3D displays. Hence, this study analyzes the effects of display type (2D vs. 3D and viewing distance on visual fatigue during a 60-min viewing session based on electroencephalogram (EEG relative beta power, and alpha/beta power ratio. In this study, twenty male participants watched four videos. The EEGs were recorded at two occipital lobes (O1 and O2 of each participant in the pre-session (3 min, post-session (3 min, and during a 60-min viewing session. The results showed that the decrease in relative beta power of the EEG and the increase in the alpha/beta ratio from the start until the end of the viewing session were significantly higher when watching the 3D display. When the viewing distance was increased from 1.95 m to 3.90 m, the visual fatigue was decreased in the case of the 3D-display, whereas the fatigue was increased in the case of the 2D-display. Moreover, there was approximately the same level of visual fatigue when watching videos in 2D or 3D from a long viewing distance (3.90 m.

  16. Digital Display Integration Project Project Online 2.0

    CERN Document Server

    Bardsley, J N

    1999-01-01

    The electronic display industry is changing in three important ways. First, the dominance of the cathode ray tube (CRT) is being challenged by the development of flat panel displays (FPDs). This will lead to the availability of displays of higher performance, albeit at greater cost. Secondly, the analog interfaces between displays that show data and the computers that generate the data are being replaced by digital connections. Finally, a high-resolution display is becoming the most expensive component in computer system for homes and small offices. It is therefore desirable that the useful lifetime of the display extend over several years and that the electronics allows the display to be used with many different image sources. Hopefully, the necessity of having three or four large CRTs in one office to accommodate different computer operating systems or communication protocols will soon disappear. Instead, we hope to see a set of flat panels that can be switched to show several independent images from multip...

  17. A programmable display layer for virtual reality system architectures.

    Science.gov (United States)

    Smit, Ferdi Alexander; van Liere, Robert; Froehlich, Bernd

    2010-01-01

    Display systems typically operate at a minimum rate of 60 Hz. However, existing VR-architectures generally produce application updates at a lower rate. Consequently, the display is not updated by the application every display frame. This causes a number of undesirable perceptual artifacts. We describe an architecture that provides a programmable display layer (PDL) in order to generate updated display frames. This replaces the default display behavior of repeating application frames until an update is available. We will show three benefits of the architecture typical to VR. First, smooth motion is provided by generating intermediate display frames by per-pixel depth-image warping using 3D motion fields. Smooth motion eliminates various perceptual artifacts due to judder. Second, we implement fine-grained latency reduction at the display frame level using a synchronized prediction of simulation objects and the viewpoint. This improves the average quality and consistency of latency reduction. Third, a crosstalk reduction algorithm for consecutive display frames is implemented, which improves the quality of stereoscopic images. To evaluate the architecture, we compare image quality and latency to that of a classic level-of-detail approach.

  18. Trophic assimilation efficiency markedly increases at higher trophic levels in four-level host-parasitoid food chain.

    Science.gov (United States)

    Sanders, Dirk; Moser, Andrea; Newton, Jason; van Veen, F J Frank

    2016-03-16

    Trophic assimilation efficiency (conversion of resource biomass into consumer biomass) is thought to be a limiting factor for food chain length in natural communities. In host-parasitoid systems, which account for the majority of terrestrial consumer interactions, a high trophic assimilation efficiency may be expected at higher trophic levels because of the close match of resource composition of host tissue and the consumer's resource requirements, which would allow for longer food chains. We measured efficiency of biomass transfer along an aphid-primary-secondary-tertiary parasitoid food chain and used stable isotope analysis to confirm trophic levels. We show high efficiency in biomass transfer along the food chain. From the third to the fourth trophic level, the proportion of host biomass transferred was 45%, 65% and 73%, respectively, for three secondary parasitoid species. For two parasitoid species that can act at the fourth and fifth trophic levels, we show markedly increased trophic assimilation efficiencies at the higher trophic level, which increased from 45 to 63% and 73 to 93%, respectively. In common with other food chains, δ(15)N increased with trophic level, with trophic discrimination factors (Δ(15)N) 1.34 and 1.49‰ from primary parasitoids to endoparasitic and ectoparasitic secondary parasitoids, respectively, and 0.78‰ from secondary to tertiary parasitoids. Owing to the extraordinarily high efficiency of hyperparasitoids, cryptic higher trophic levels may exist in host-parasitoid communities, which could alter our understanding of the dynamics and drivers of community structure of these important systems. © 2016 The Authors.

  19. 3D display system using monocular multiview displays

    Science.gov (United States)

    Sakamoto, Kunio; Saruta, Kazuki; Takeda, Kazutoki

    2002-05-01

    A 3D head mounted display (HMD) system is useful for constructing a virtual space. The authors have researched the virtual-reality systems connected with computer networks for real-time remote control and developed a low-priced real-time 3D display for building these systems. We developed a 3D HMD system using monocular multi-view displays. The 3D displaying technique of this monocular multi-view display is based on the concept of the super multi-view proposed by Kajiki at TAO (Telecommunications Advancement Organization of Japan) in 1996. Our 3D HMD has two monocular multi-view displays (used as a visual display unit) in order to display a picture to the left eye and the right eye. The left and right images are a pair of stereoscopic images for the left and right eyes, then stereoscopic 3D images are observed.

  20. Circular displays: control/display arrangements and stereotype strength with eight different display locations.

    Science.gov (United States)

    Chan, Alan H S; Hoffmann, Errol R

    2015-01-01

    Two experiments are reported that were designed to investigate control/display arrangements having high stereotype strengths when using circular displays. Eight display locations relative to the operator and control were tested with rotational and translational controls situated on different planes according to the Frame of Reference Transformation Tool (FORT) model of Wickens et al. (2010). (Left. No, Right! Development of the Frame of Reference Transformation Tool (FORT), Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting, 54: 1022-1026). In many cases, there was little effect of display locations, indicating the importance of the Worringham and Beringer (1998. Directional stimulus-response compatibility: a test of three alternative principles. Ergonomics, 41(6), 864-880) Visual Field principle and an extension of this principle for rotary controls (Hoffmann and Chan (2013). The Worringham and Beringer 'visual field' principle for rotary controls. Ergonomics, 56(10), 1620-1624). The initial indicator position (12, 3, 6 and 9 o'clock) had a major effect on control/display stereotype strength for many of the six controls tested. Best display/control arrangements are listed for each of the different control types (rotational and translational) and for the planes on which they are mounted. Data have application where a circular display is used due to limited display panel space and applies to space-craft, robotics operators, hospital equipment and home appliances. Practitioner Summary: Circular displays are often used when there is limited space available on a control panel. Display/control arrangements having high stereotype strength are listed for four initial indicator positions. These arrangements are best for design purposes.

  1. Higher-level gait disorders: an open frontier.

    Science.gov (United States)

    Nutt, John G

    2013-09-15

    The term higher-level gait disorders (HLGD) defines a category of balance and gait disorders that are not explained by deficits in strength, tone, sensation, or coordination. HLGD are characterized by various combinations of disequilibrium and impaired locomotion. A plethora of new imaging techniques are beginning to determine the neural circuits that are the basis of these disorders. Although a variety of neurodegenerative and other pathologies can produce HLGD, the most common cause appears to be microvascular disease that causes white-matter lesions and thereby disrupts balance/locomotor circuits. © 2013 Movement Disorder Society.

  2. Emotional display rules as work unit norms: a multilevel analysis of emotional labor among nurses.

    Science.gov (United States)

    Diefendorff, James M; Erickson, Rebecca J; Grandey, Alicia A; Dahling, Jason J

    2011-04-01

    Emotional labor theory has conceptualized emotional display rules as shared norms governing the expression of emotions at work. Using a sample of registered nurses working in different units of a hospital system, we provided the first empirical evidence that display rules can be represented as shared, unit-level beliefs. Additionally, controlling for the influence of dispositional affectivity, individual-level display rule perceptions, and emotion regulation, we found that unit-level display rules are associated with individual-level job satisfaction. We also showed that unit-level display rules relate to burnout indirectly through individual-level display rule perceptions and emotion regulation strategies. Finally, unit-level display rules also interacted with individual-level dispositional affectivity to predict employee use of emotion regulation strategies. We discuss how future research on emotional labor and display rules, particularly in the health care setting, can build on these findings.

  3. Image Quality Characteristics of Handheld Display Devices for Medical Imaging

    Science.gov (United States)

    Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo

    2013-01-01

    Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113

  4. Cerebrospinal fluid cortisol levels are higher in patients with delirium versus controls

    Directory of Open Access Journals (Sweden)

    White Timothy O

    2010-02-01

    Full Text Available Abstract Background High plasma cortisol levels can cause acute cognitive and neuropsychiatric dysfunction, and have been linked with delirium. CSF cortisol levels more closely reflect brain exposure to cortisol, but there are no studies of CSF cortisol levels in delirium. In this pilot study we acquired CSF specimens at the onset of spinal anaesthesia in patients undergoing hip fracture surgery, and compared CSF and plasma cortisol levels in delirium cases versus controls. Findings Delirium assessments were performed the evening before or on the morning of operation with a standard battery comprising cognitive tests, mental status assessments and the Confusion Assessment Method. CSF and plasma samples were obtained at the onset of the operation and cortisol levels measured. Twenty patients (15 female, 5 male aged 62 - 93 years were studied. Seven patients were diagnosed with delirium. The mean ages of cases (81.4 (SD 7.2 and controls (80.5 (SD 8.7 were not significantly different (p = 0.88. The median (interquartile range CSF cortisol levels were significantly higher in cases (63.9 (40.4-102.1 nmol/L than controls (31.4 (21.7-43.3 nmol/L; Mann-Whitney U, p = 0.029. The median (interquartile range of plasma cortisol was also significantly higher in cases (968.8 (886.2-1394.4 nmol/L, than controls (809.4 (544.0-986.4 nmol/L; Mann Whitney U, p = 0.036. Conclusions These findings support an association between higher CSF cortisol levels and delirium. This extends previous findings linking higher plasma cortisol and delirium, and suggests that more definitive studies of the relationship between cortisol levels and delirium are now required.

  5. Usability Comparisons of Head-Mounted vs. Stereoscopic Desktop Displays in a Virtual Reality Environment with Pain Patients.

    Science.gov (United States)

    Tong, Xin; Gromala, Diane; Gupta, Dimple; Squire, Pam

    2016-01-01

    Researchers have shown that immersive Virtual Reality (VR) can serve as an unusually powerful pain control technique. However, research assessing the reported symptoms and negative effects of VR systems indicate that it is important to ascertain if these symptoms arise from the use of particular VR display devices, particularly for users who are deemed "at risk," such as chronic pain patients Moreover, these patients have specific and often complex needs and requirements, and because basic issues such as 'comfort' may trigger anxiety or panic attacks, it is important to examine basic questions of the feasibility of using VR displays. Therefore, this repeated-measured experiment was conducted with two VR displays: the Oculus Rift's head-mounted display (HMD) and Firsthand Technologies' immersive desktop display, DeepStream3D. The characteristics of these immersive desktop displays differ: one is worn, enabling patients to move their heads, while the other is peered into, allowing less head movement. To assess the severity of physical discomforts, 20 chronic pain patients tried both displays while watching a VR pain management demo in clinical settings. Results indicated that participants experienced higher levels of Simulator Sickness using the Oculus Rift HMD. However, results also indicated other preferences of the two VR displays among patients, including physical comfort levels and a sense of immersion. Few studies have been conducted that compare usability of specific VR devices specifically with chronic pain patients using a therapeutic virtual environment in pain clinics. Thus, the results may help clinicians and researchers to choose the most appropriate VR displays for chronic pain patients and guide VR designers to enhance the usability of VR displays for long-term pain management interventions.

  6. Storytelling in the digital world: achieving higher-level learning objectives.

    Science.gov (United States)

    Schwartz, Melissa R

    2012-01-01

    Nursing students are not passive media consumers but instead live in a technology ecosystem where digital is the language they speak. To prepare the next generation of nurses, educators must incorporate multiple technologies to improve higher-order learning. The author discusses the evolution and use of storytelling as part of the digital world and how digital stories can be aligned with Bloom's Taxonomy so that students achieve higher-level learning objectives.

  7. Image quality evaluation of medical color and monochrome displays using an imaging colorimeter

    Science.gov (United States)

    Roehrig, Hans; Gu, Xiliang; Fan, Jiahua

    2012-10-01

    The purpose of this presentation is to demonstrate the means which permit examining the accuracy of Image Quality with respect to MTF (Modulation Transfer Function) and NPS (Noise Power Spectrum) of Color Displays and Monochrome Displays. Indications were in the past that color displays could affect the clinical performance of color displays negatively compared to monochrome displays. Now colorimeters like the PM-1423 are available which have higher sensitivity and color accuracy than the traditional cameras like CCD cameras. Reference (1) was not based on measurements made with a colorimeter. This paper focuses on the measurements of physical characteristics of the spatial resolution and noise performance of color and monochrome medical displays which were made with a colorimeter and we will after this meeting submit the data to an ROC study so we have again a paper to present at a future SPIE Conference.Specifically, Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) were evaluated and compared at different digital driving levels (DDL) between the two medical displays. This paper focuses on the measurements of physical characteristics of the spatial resolution and noise performance of color and monochrome medical displays which were made with a colorimeter and we will after this meeting submit the data to an ROC study so we have again a paper to present at a future Annual SPIE Conference. Specifically, Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) were evaluated and compared at different digital driving levels (DDL) between the two medical displays. The Imaging Colorimeter. Measurement of color image quality needs were done with an imaging colorimeter as it is shown below. Imaging colorimetry is ideally suited to FPD measurement because imaging systems capture spatial data generating millions of data points in a single measurement operation. The imaging colorimeter which was used was the PM-1423 from Radiant Imaging. It uses

  8. Excel Spreadsheet Tools for Analyzing Groundwater Level Records and Displaying Information in ArcMap

    Science.gov (United States)

    Tillman, Fred D.

    2009-01-01

    When beginning hydrologic investigations, a first action is often to gather existing sources of well information, compile this information into a single dataset, and visualize this information in a geographic information system (GIS) environment. This report presents tools (macros) developed using Visual Basic for Applications (VBA) for Microsoft Excel 2007 to assist in these tasks. One tool combines multiple datasets into a single worksheet and formats the resulting data for use by the other tools. A second tool produces summary information about the dataset, such as a list of unique site identification numbers, the number of water-level observations for each, and a table of the number of sites with a listed number of water-level observations. A third tool creates subsets of the original dataset based on user-specified options and produces a worksheet with water-level information for each well in the subset, including the average and standard deviation of water-level observations and maximum decline and rise in water levels between any two observations, among other information. This water-level information worksheet can be imported directly into ESRI ArcMap as an 'XY Data' file, and each of the fields of summary well information can be used for custom display. A separate set of VBA tools distributed in an additional Excel workbook creates hydrograph charts of each of the wells in the data subset produced by the aforementioned tools and produces portable document format (PDF) versions of the hydrograph charts. These PDF hydrographs can be hyperlinked to well locations in ArcMap or other GIS applications.

  9. Survey of standards for electronic image displays

    Science.gov (United States)

    Rowe, William A.

    1996-02-01

    Electronic visual displays have been evolving from the 1960's basis of cathode ray tube (CRT) technology. Now, many other technologies are also available, including both flat panels and projection displays. Standards for these displays are being developed at both the national level and the international levels. Standards activity within the United States is in its infancy and is fragmented according to the inclination of each of the standards developing organizations. The latest round of flat panel display technology was primarily developed in Japan. Initially standards arose from component vendor-to-OEM customer relationships. As a result, Japanese standards for components are the best developed. The Electronics Industries Association of Japan (EIAJ) is providing their standards to the International Electrotechnical Commission (IEC) for adoption. On the international level, professional societies such as the human factors society (hfs) and the International Organization for Standardization (ISO) have completed major standards, hfs developed the first ergonomic standard hfs-100 and the ISO has developed some sections of a broader ergonomic standard ISO 9241. This paper addresses the organization of standards activity. Active organizations and their areas of focus are identified. The major standards that have been completed or are in development are described. Finally, suggestions for improving the this standards activity are proposed.

  10. Egyptian greenhouse cultivation at a higher level with Dutch Technology ; Annual Report 2013

    NARCIS (Netherlands)

    Elings, A.; Helm, van der F.P.M.; Blok, C.; Meijer, R.J.M.; Lahiani, Y.; Janmaat, A.; Zaki, M.; Hassan, H.

    2014-01-01

    The project ‘Egyptian greenhouse cultivation at a higher level with Dutch technology’ is co-funded under the Top Sector Programme Horticulture and Starting Materials. The project wants to realizes through the use of Dutch technology a higher level of sustainability of Egyptian protected cultivation,

  11. Higher transcription levels in ascorbic acid biosynthetic and recycling genes were associated with higher ascorbic acid accumulation in blueberry.

    Science.gov (United States)

    Liu, Fenghong; Wang, Lei; Gu, Liang; Zhao, Wei; Su, Hongyan; Cheng, Xianhao

    2015-12-01

    In our preliminary study, the ripe fruits of two highbush blueberry (Vaccinium corymbosum L.) cultivars, cv 'Berkeley' and cv 'Bluecrop', were found to contain different levels of ascorbic acid. However, factors responsible for these differences are still unknown. In the present study, ascorbic acid content in fruits was compared with expression profiles of ascorbic acid biosynthetic and recycling genes between 'Bluecrop' and 'Berkeley' cultivars. The results indicated that the l-galactose pathway was the predominant route of ascorbic acid biosynthesis in blueberry fruits. Moreover, higher expression levels of the ascorbic acid biosynthetic genes GME, GGP, and GLDH, as well as the recycling genes MDHAR and DHAR, were associated with higher ascorbic acid content in 'Bluecrop' compared with 'Berkeley', which indicated that a higher efficiency ascorbic acid biosynthesis and regeneration was likely to be responsible for the higher ascorbic acid accumulation in 'Bluecrop'. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Generating high gray-level resolution monochrome displays with conventional computer graphics cards and color monitors.

    Science.gov (United States)

    Li, Xiangrui; Lu, Zhong-Lin; Xu, Pengjing; Jin, Jianzhong; Zhou, Yifeng

    2003-11-30

    Display systems based on conventional computer graphics cards are capable of generating images with about 8-bit luminance resolution. However, most vision experiments require more than 12 bits of luminance resolution. Pelli and Zhang [Spatial Vis. 10 (1997) 443] described a video attenuator for generating high luminance resolution displays on a monochrome monitor, or for driving just the green gun of a color monitor. Here we show how to achieve a white display by adding video amplifiers to duplicate the monochrome signal to drive all three guns of any color monitor. Because of the lack of the availability of high quality monochrome monitors, our method provides an inexpensive way to achieve high-resolution monochromatic displays using conventional, easy-to-get equipment. We describe the design principles, test results, and a few additional functionalities.

  13. Higher fuel prices are associated with lower air pollution levels.

    Science.gov (United States)

    Barnett, Adrian G; Knibbs, Luke D

    2014-05-01

    Air pollution is a persistent problem in urban areas, and traffic emissions are a major cause of poor air quality. Policies to curb pollution levels often involve raising the price of using private vehicles, for example, congestion charges. We were interested in whether higher fuel prices were associated with decreased air pollution levels. We examined an association between diesel and petrol prices and four traffic-related pollutants in Brisbane from 2010 to 2013. We used a regression model and examined pollution levels up to 16 days after the price change. Higher diesel prices were associated with statistically significant short-term reductions in carbon monoxide and nitrogen oxides. Changes in petrol prices had no impact on air pollution. Raising diesel taxes in Australia could be justified as a public health measure. As raising taxes is politically unpopular, an alternative political approach would be to remove schemes that put a downward pressure on fuel prices, such as industry subsidies and shopping vouchers that give fuel discounts. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Rating Emotion Communication: Display and Concealment as Effects of Culture, Gender, Emotion Type, and Relationship

    Directory of Open Access Journals (Sweden)

    Arne Vikan

    2009-01-01

    Full Text Available Students from a collectivistic (Brazilian, n= 401 and an individualistic (Norwegian, n= 418culture rated their ability to display and conceal anger, sadness, and anxiety in relation to immediate family, partner, friends, and "other persons." Norwegians showed higher display ratings for anger and sadness, and higher concealment ratings for anger and anxiety. Display ratings were much higher, and concealment ratings much lower in relation to close persons than in relation to "other persons." A culture x relationship interaction was that Brazilian' ratings suggested more emotional openness to friends than to family and partner, whereas Norwegians showed the inverse patterns. Gender differences supported previous research by showing higher display and lower concealment ratings, and less differentiation between relationships by females.

  15. Lateralisation of aggressive displays in a tephritid fly

    Science.gov (United States)

    Benelli, Giovanni; Donati, Elisa; Romano, Donato; Stefanini, Cesare; Messing, Russell H.; Canale, Angelo

    2015-02-01

    Lateralisation (i.e. different functional and/or structural specialisations of the left and right sides of the brain) of aggression has been examined in several vertebrate species, while evidence for invertebrates is scarce. In this study, we investigated lateralisation of aggressive displays (boxing with forelegs and wing strikes) in the Mediterranean fruit fly, Ceratitis capitata. We attempted to answer the following questions: (1) do medflies show lateralisation of aggressive displays at the population-level; (2) are there sex differences in lateralisation of aggressive displays; and (3) does lateralisation of aggression enhance fighting success? Results showed left-biased population-level lateralisation of aggressive displays, with no consistent differences among sexes. In both male-male and female-female conflicts, aggressive behaviours performed with left body parts led to greater fighting success than those performed with right body parts. As we found left-biased preferential use of body parts for both wing strikes and boxing, we predicted that the left foreleg/wing is quicker in exploring/striking than the right one. We characterised wing strike and boxing using high-speed videos, calculating mean velocity of aggressive displays. For both sexes, aggressive displays that led to success were faster than unsuccessful ones. However, left wing/legs were not faster than right ones while performing aggressive acts. Further research is needed on proximate causes allowing enhanced fighting success of lateralised aggressive behaviour. This is the first report supporting the adaptive role of lateralisation of aggressive displays in insects.

  16. OLED Display For Real Time Vision System

    Directory of Open Access Journals (Sweden)

    Sandhyalakshmi Narayanan

    2015-08-01

    Full Text Available This innovative glass design will carry an OLED based display controlled via nano Ardiuno board having Bluetooth connectivity with a Smartphone to exchange information along with onboard accelerometer. We are using a tilt angle sensor for detecting if the driver is feeling drowsy. An alcohol sensor has been used to promote the safe driving habit. The glasses will be getting latest updates about the current speed of the vehicle navigation directions nearby or approaching sign broads or services like petrol pumps. Itll also display information like incoming calls or received messages. All this information will be obtained through a Smartphone connected via Bluetooth. Also the car mileage can be monitored with help of fuel sensor as the consumption of fuel is directly related to it. Abnormalities if detected will be immediately notified in the glasses. Also the angle of the tilt angle sensor can be defined and set by the user according to his needs. Also the main idea of using OLED glasses is that it is organic thereby helps in reducing the carbon footprint and is quite slim. Therefore it can be easily mounted on the specs without making it heavy. Also they higher level of flexibility and have low power drain and energy consumption

  17. Organizational Citizenship Behavior (OCB) Display Levels of the Teachers at Secondary Schools According to the Perceptions of the School Administrators

    Science.gov (United States)

    Polat, Soner

    2009-01-01

    The main aim of this study is to determine in what level the teachers at secondary schools display organizational citizenship behavior (OCB) according to the perceptions of the school administrators. The data of this study, which is descriptive, were collected via the "the scale of OCB" which was developed by Podsakoff, MacKenzie,…

  18. Looking forward: In-vehicle auxiliary display positioning affects carsickness.

    Science.gov (United States)

    Kuiper, Ouren X; Bos, Jelte E; Diels, Cyriel

    2018-04-01

    Carsickness is associated with a mismatch between actual and anticipated sensory signals. Occupants of automated vehicles, especially when using a display, are at higher risk of becoming carsick than drivers of conventional vehicles. This study aimed to evaluate the impact of positioning of in-vehicle displays, and subsequent available peripheral vision, on carsickness of passengers. We hypothesized that increased peripheral vision during display use would reduce carsickness. Seated in the front passenger seat 18 participants were driven a 15-min long slalom on two occasions while performing a continuous visual search-task. The display was positioned either at 1) eye-height in front of the windscreen, allowing peripheral view on the outside world, and 2) the height of the glove compartment, allowing only limited view on the outside world. Motion sickness was reported at 1-min intervals. Using a display at windscreen height resulted in less carsickness compared to a display at glove compartment height. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Psychophysical analysis of monitor display functions affecting observer diagnostic performance of CT image on liquid crystal display monitors

    International Nuclear Information System (INIS)

    Yamaguchi, M.; Fujita, H.; Asai, Y.; Uemura, M.; Ookura, Y.; Matsumoto, M.; Johkoh, T.

    2005-01-01

    The aim of the present study was to propose suitable display functions for CT image representation on liquid crystal display (LCD) monitors by analyzing the characteristics of the monitor's typical display functions using psychophysical analysis. The luminance of the LCD monitor was adjusted to a maximum of 275 cd/m 2 and 480 cd/m 2 . Three types of postcalibrated display functions (i.e., GSDF, CIELAB, and Exponential γ 2.2) were evaluated. Luminance calculation of a new grayscale test pattern (NGTP) was done for the conversion of the digital driving level (DDL) into the CT value. The psychophysical gradient δ of display functions for the CT value was evaluated and compared via statistical analysis. The δ value of GSDF and CIE decreased exponentially; however, the δ value of Exponential γ 2.2 showed a convex curve with a peak at a specific point. There was a statistically significant difference among the δ values of the three types of display functions on the 480 cd/m 2 maximum via Kruskal Wallis test (P<0.001). The GSDF was suitable for observation of abdominal and lung CT images; however, the display function combined the Exponential γ 2.2 and the GSDF functions and was ideal for observation of brain CT images by psychophysical analysis. (orig.)

  20. An empirical study on educational investment for all levels of higher education in China

    OpenAIRE

    YANG Juan; David MAYSTON

    2009-01-01

    With the expanding of higher education in China from 1999, more and more youngsters are able to invest in higher education, resulting a high unemployment rate for higher education graduates and more and more graduates employed in non-graduate position, while the analysis upon risk and return to each level of high education is absent due to the limitation of dataset. The paper employs college students sample survey to research the determinants of all levels of higher education beginning wages,...

  1. A higher-level MRP supertree of placental mammals

    Directory of Open Access Journals (Sweden)

    Bininda-Emonds Olaf RP

    2006-11-01

    Full Text Available Abstract Background The higher-level phylogeny of placental mammals has long been a phylogenetic Gordian knot, with disagreement about both the precise contents of, and relationships between, the extant orders. A recent MRP supertree that favoured 'outdated' hypotheses (notably, monophyly of both Artiodactyla and Lipotyphla has been heavily criticised for including low-quality and redundant data. We apply a stringent data selection protocol designed to minimise these problems to a much-expanded data set of morphological, molecular and combined source trees, to produce a supertree that includes every family of extant placental mammals. Results The supertree is well-resolved and supports both polyphyly of Lipotyphla and paraphyly of Artiodactyla with respect to Cetacea. The existence of four 'superorders' – Afrotheria, Xenarthra, Laurasiatheria and Euarchontoglires – is also supported. The topology is highly congruent with recent (molecular phylogenetic analyses of placental mammals, but is considerably more comprehensive, being the first phylogeny to include all 113 extant families without making a priori assumptions of suprafamilial monophyly. Subsidiary analyses reveal that the data selection protocol played a key role in the major changes relative to a previously published higher-level supertree of placentals. Conclusion The supertree should provide a useful framework for hypothesis testing in phylogenetic comparative biology, and supports the idea that biogeography has played a crucial role in the evolution of placental mammals. Our results demonstrate the importance of minimising poor and redundant data when constructing supertrees.

  2. Patients with Ankylosing Spondylitis and Low Disease Activity because of Anti-TNF-Alpha Therapy Have Higher TRAIL Levels Than Controls: A Potential Compensatory Effect

    Directory of Open Access Journals (Sweden)

    Fernanda Genre

    2014-01-01

    Full Text Available Objective. TRAIL is a potential biomarker of cardiovascular (CV disease. Ankylosing spondylitis (AS is a chronic inflammatory disease associated with metabolic syndrome (MeS and accelerated atherosclerosis. We assessed whether disease activity, systemic inflammation, and MeS features were associated with circulating TRAIL levels in AS patients undergoing TNF-α antagonist infliximab therapy and if infliximab infusion modified TRAIL levels. Methods. We measured TRAIL serum levels in 30 nondiabetic AS patients without CV disease undergoing anti-TNF-α therapy, immediately before and after an infliximab infusion, and in 48 matched controls. Correlations of TRAIL levels with disease activity, systemic inflammation and MeS features, adipokines, and biomarkers of endothelial activation were evaluated. Changes in TRAIL levels following anti-TNF-α infusion were analyzed. Results. TRAIL levels were higher in AS patients than controls. TRAIL levels displayed an inverse correlation with total and LDL cholesterol. We observed an inverse correlation with QUICKI and a marginal association with HOMA-IR. We also found an inverse correlation with resistin and a marginal association with apelin and OPN. Anti-TNF-α infusion did not change TRAIL levels after 120′. Conclusion. Elevated TRAIL levels in AS patients may be the result of a compensatory mechanism to reduce CV risk in these patients.

  3. Projection display industry market and technology trends

    Science.gov (United States)

    Castellano, Joseph A.; Mentley, David E.

    1995-04-01

    The projection display industry is diverse, embracing a variety of technologies and applications. In recent years, there has been a high level of interest in projection displays, particularly those using LCD panels or light valves because of the difficulty in making large screen, direct view displays. Many developers feel that projection displays will be the wave of the future for large screen HDTV (high-definition television), penetrating the huge existing market for direct view CRT-based televisions. Projection displays can have the images projected onto a screen either from the rear or the front; the main characteristic is their ability to be viewed by more than one person. In addition to large screen home television receivers, there are numerous other uses for projection displays including conference room presentations, video conferences, closed circuit programming, computer-aided design, and military command/control. For any given application, the user can usually choose from several alternative technologies. These include CRT front or rear projectors, LCD front or rear projectors, LCD overhead projector plate monitors, various liquid or solid-state light valve projectors, or laser-addressed systems. The overall worldwide market for projection information displays of all types and for all applications, including home television, will top DOL4.6 billion in 1995 and DOL6.45 billion in 2001.

  4. Operational characteristics of pediatric radiology: Image display stations

    International Nuclear Information System (INIS)

    Taira, R.K.

    1987-01-01

    The display of diagnostic images is accomplished in the UCLA Pediatric Radiology Clinical Radiology Imaging System (CRIS) using 3 different types of digital viewing stations. These include a low resolution station with six 512 x 512 monitors, a high resolution station with three 1024 x 1024 monitors, and a very high resolution workstation with two 2048 x 2048 monitors. The display stations provide very basic image processing manipulations including zoom and scroll, contrast enhancement, and contrast reversal. The display stations are driven by a computer system which is dedicated for clinical use. During times when the clinical computer is unavailable (maintenance or system malfunction), the 512 x 512 workstation can be switched to operate from a research PACS system in the UCLA Image Processing Laboratory via a broadband communication network. Our initial clinical implementation involves digital viewing for pediatric radiology conferences. Presentation of inpatient cases use the six monitor 512 x 512 multiple viewing station. Later stages of the clinical implementation involve the use of higher resolution displays for the purpose of primary diagnosis from video displays

  5. European display scene

    Science.gov (United States)

    Bartlett, Christopher T.

    2000-08-01

    The manufacture of Flat Panel Displays (FPDs) is dominated by Far Eastern sources, particularly in Active Matrix Liquid Crystal Displays (AMLCD) and Plasma. The United States has a very powerful capability in micro-displays. It is not well known that Europe has a very active research capability which has lead to many innovations in display technology. In addition there is a capability in display manufacturing of organic technologies as well as the licensed build of Japanese or Korean designs. Finally, Europe has a display systems capability in military products which is world class.

  6. Effect of display location on control-display stereotype strength for translational and rotational controls with linear displays.

    Science.gov (United States)

    Chan, Alan H S; Hoffmann, Errol R

    2015-01-01

    Experiments were designed to investigate the effects of control type and display location, relative to the operator, on the strength of control/display stereotypes. The Worringham and Beringer Visual Field principle and an extension of this principle for rotary controls (Hoffmann E.R., and Chan A.H.S. 2013). "The Worringham and Beringer 'Visual Field' Principle for Rotary Controls. Ergonomics." 56 (10): 1620-1624) indicated that, for a number of different control types (rotary and lever) on different planes, there should be no significant effect of the display location relative to the seated operator. Past data were surveyed and stereotype strengths listed. Experiments filled gaps where data are not available. Six different control types and seven display locations were used, as in the Frame of Reference Transformation Tool (FORT) model of Wickens et al. (Wickens, C.D., Keller, J.W., and Small, R.L. (2010). "Left. No, Right! Development of the Frame of Reference Transformation Tool (FORT)." Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting September 2010, 54: 1022-1026). Control/display arrangements with high stereotype strengths were evaluated yielding data for designers of complex control/display arrangements where the control and display are in different planes and for where the operator is moving. It was found possible to predict display/control arrangements with high stereotype strength, based on past data. Practitioner Summary: Controls and displays in complex arrangements need to have high compatibility. These experiments provide arrangements for six different controls (rotary and translational) and seven different display locations relative to the operator.

  7. Visual Acuity does not Moderate Effect Sizes of Higher-Level Cognitive Tasks

    Science.gov (United States)

    Houston, James R.; Bennett, Ilana J.; Allen, Philip A.; Madden, David J.

    2016-01-01

    Background Declining visual capacities in older adults have been posited as a driving force behind adult age differences in higher-order cognitive functions (e.g., the “common cause” hypothesis of Lindenberger & Baltes, 1994). McGowan, Patterson and Jordan (2013) also found that a surprisingly large number of published cognitive aging studies failed to include adequate measures of visual acuity. However, a recent meta-analysis of three studies (LaFleur & Salthouse, 2014) failed to find evidence that visual acuity moderated or mediated age differences in higher-level cognitive processes. In order to provide a more extensive test of whether visual acuity moderates age differences in higher-level cognitive processes, we conducted a more extensive meta-analysis of topic. Methods Using results from 456 studies, we calculated effect sizes for the main effect of age across four cognitive domains (attention, executive function, memory, and perception/language) separately for five levels of visual acuity criteria (no criteria, undisclosed criteria, self-reported acuity, 20/80-20/31, and 20/30 or better). Results As expected, age had a significant effect on each cognitive domain. However, these age effects did not further differ as a function of visual acuity criteria. Conclusion The current meta-analytic, cross-sectional results suggest that visual acuity is not significantly related to age group differences in higher-level cognitive performance—thereby replicating LaFleur and Salthouse (2014). Further efforts are needed to determine whether other measures of visual functioning (e.g. contrast sensitivity, luminance) affect age differences in cognitive functioning. PMID:27070044

  8. Preferred viewing distance and screen angle of electronic paper displays.

    Science.gov (United States)

    Shieh, Kong-King; Lee, Der-Song

    2007-09-01

    This study explored the viewing distance and screen angle for electronic paper (E-Paper) displays under various light sources, ambient illuminations, and character sizes. Data analysis showed that the mean viewing distance and screen angle were 495 mm and 123.7 degrees. The mean viewing distances for Kolin Chlorestic Liquid Crystal display was 500 mm, significantly longer than Sony electronic ink display, 491 mm. Screen angle for Kolin was 127.4 degrees, significantly greater than that of Sony, 120.0 degrees. Various light sources revealed no significant effect on viewing distances; nevertheless, they showed significant effect on screen angles. The screen angle for sunlight lamp (D65) was similar to that of fluorescent lamp (TL84), but greater than that of tungsten lamp (F). Ambient illumination and E-paper type had significant effects on viewing distance and screen angle. The higher the ambient illumination was, the longer the viewing distance and the lesser the screen angle. Character size had significant effect on viewing distances: the larger the character size, the longer the viewing distance. The results of this study indicated that the viewing distance for E-Paper was similar to that of visual display terminal (VDT) at around 500 mm, but greater than normal paper at about 360 mm. The mean screen angle was around 123.7 degrees, which in terms of viewing angle is 29.5 degrees below horizontal eye level. This result is similar to the general suggested viewing angle between 20 degrees and 50 degrees below the horizontal line of sight.

  9. Franck--Hertz experiment with higher excitation level measurements

    International Nuclear Information System (INIS)

    Liu, F.H.

    1987-01-01

    The measurement of the higher levels of 6 3 P 2 and 6 1 P 1 of the mercury atom in the Franck--Hertz experiment has been introduced into the junior and senior laboratory course by using a homemade tetrode Franck--Hertz tube. The main structure of the tube is described. The optimum operating conditions are in the temperature range between 130 and 150 0 C and the collector currents are of the order of 10 -9 A. The additional observations of the famous Franck--Hertz experiment in the laboratory course will give the students more familiarity with the quantum behavior of atoms

  10. Cell wall structure suitable for surface display of proteins in Saccharomyces cerevisiae.

    Science.gov (United States)

    Matsuoka, Hiroyuki; Hashimoto, Kazuya; Saijo, Aki; Takada, Yuki; Kondo, Akihiko; Ueda, Mitsuyoshi; Ooshima, Hiroshi; Tachibana, Taro; Azuma, Masayuki

    2014-02-01

    A display system for adding new protein functions to the cell surfaces of microorganisms has been developed, and applications of the system to various fields have been proposed. With the aim of constructing a cell surface environment suitable for protein display in Saccharomyces cerevisiae, the cell surface structures of cell wall mutants were investigated. Four cell wall mutant strains were selected by analyses using a GFP display system via a GPI anchor. β-Glucosidase and endoglucanase II were displayed on the cell surface in the four mutants, and their activities were evaluated. mnn2 deletion strain exhibited the highest activity for both the enzymes. In particular, endoglucanase II activity using carboxymethylcellulose as a substrate in the mutant strain was 1.9-fold higher than that of the wild-type strain. In addition, the activity of endoglucanase II released from the mnn2 deletion strain by Zymolyase 20T treatment was higher than that from the wild-type strain. The results of green fluorescent protein (GFP) and endoglucanase displays suggest that the amounts of enzyme displayed on the cell surface were increased by the mnn2 deletion. The enzyme activity of the mnn2 deletion strain was compared with that of the wild-type strain. The relative value (mnn2 deletion mutant/wild-type strain) of endoglucanase II activity using carboxymethylcellulose as a substrate was higher than that of β-glucosidase activity using p-nitrophenyl-β-glucopyranoside as a substrate, suggesting that the cell surface environment of the mnn2 deletion strain facilitates the binding of high-molecular-weight substrates to the active sites of the displayed enzymes. Copyright © 2014 John Wiley & Sons, Ltd.

  11. Perceived Effectiveness of Professional Development Programs of Teachers at Higher Education Level

    Science.gov (United States)

    Malik, Sufiana Khatoon; Nasim, Uzma; Tabassum, Farkhanda

    2015-01-01

    The major purpose of the study was to assess the perceived effectiveness of professional development programs of teachers at higher educational level. The objectives of the study were: "to assess university level teachers'" opinion about effectiveness of professional development training with reference to quality teaching, to measure…

  12. Projection display technology and product trends

    Science.gov (United States)

    Kahn, Frederic J.

    1999-05-01

    Major technology and market trends that could generate a 20 billion dollar electronic projector market by 2010 are reviewed in the perspective of recent product introductions. A log linear analysis shows that the light outputs of benchmark transportable data video projectors have increased at a rate of almost 90 percent per year since 1993. The list prices of these same projectors have decreased at a rate of over 40 percent per year. The tradeoffs of light output vs. resolution and weight are illustrated. Recent trends in projector efficacy vs. year are discussed. Lumen output per dollar of list price is shown to be a useful market metric. Continued technical advances and innovations including higher throughput light valve technologies with integrated drivers, brighter light source, field sequential color, integrated- and micro-optical components, and aerospace materials are likely to sustain these trends. The new technologies will enable projection displays for entertainment and computer applications with unprecedented levels of performance, compactness, and cost-effectiveness.

  13. Determination of critical levels of residual oxygen to minimize discoloration of sliced packaged Norwegian salami under light display.

    Science.gov (United States)

    Sørheim, Oddvin; Måge, Ingrid; Larsen, Hanne

    2017-07-01

    Discoloration of sliced packaged salami is contributing to rejection of the product, food waste and economical loss. A combination of residual O 2 in the headspace of packages and light is causing photooxidation and deterioration of colour. The aim of this study was to establish maximum tolerable concentrations of residual O 2 in packages of salami slices with 100% N 2 under light display at 4 and 20°C. Salami sausages had variable inherent O 2 consumption rate. Storage of salami in 1% O 2 in darkness did not induce discoloration. The upper limits for O 2 for avoiding discoloration under light were variable in the range 0.1-1.0%, depending on temperature and type of salami. Display at 20°C increased the rate of O 2 depletion compared to 4°C. To minimize discoloration, sliced and packaged salami should be stored in darkness at approximately 20°C until the level of residual O 2 is reduced below a critical limit. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Seeking a Higher Level of Arts Integration across the Curriculum

    Science.gov (United States)

    Sotiropoulou-Zormpala, Marina

    2016-01-01

    To seek a higher level of arts integration across the education curriculum, I investigated designs of teaching through arts activities that would motivate educators to adopt the spirit of "aesthetic teaching." Two different designs were tested, with the second as a continuation of the first. Each ascribes a different educational role to…

  15. Monocular display unit for 3D display with correct depth perception

    Science.gov (United States)

    Sakamoto, Kunio; Hosomi, Takashi

    2009-11-01

    A study of virtual-reality system has been popular and its technology has been applied to medical engineering, educational engineering, a CAD/CAM system and so on. The 3D imaging display system has two types in the presentation method; one is a 3-D display system using a special glasses and the other is the monitor system requiring no special glasses. A liquid crystal display (LCD) recently comes into common use. It is possible for this display unit to provide the same size of displaying area as the image screen on the panel. A display system requiring no special glasses is useful for a 3D TV monitor, but this system has demerit such that the size of a monitor restricts the visual field for displaying images. Thus the conventional display can show only one screen, but it is impossible to enlarge the size of a screen, for example twice. To enlarge the display area, the authors have developed an enlarging method of display area using a mirror. Our extension method enables the observers to show the virtual image plane and to enlarge a screen area twice. In the developed display unit, we made use of an image separating technique using polarized glasses, a parallax barrier or a lenticular lens screen for 3D imaging. The mirror can generate the virtual image plane and it enlarges a screen area twice. Meanwhile the 3D display system using special glasses can also display virtual images over a wide area. In this paper, we present a monocular 3D vision system with accommodation mechanism, which is useful function for perceiving depth.

  16. Industrial Personal Computer based Display for Nuclear Safety System

    International Nuclear Information System (INIS)

    Kim, Ji Hyeon; Kim, Aram; Jo, Jung Hee; Kim, Ki Beom; Cheon, Sung Hyun; Cho, Joo Hyun; Sohn, Se Do; Baek, Seung Min

    2014-01-01

    The safety display of nuclear system has been classified as important to safety (SIL:Safety Integrity Level 3). These days the regulatory agencies are imposing more strict safety requirements for digital safety display system. To satisfy these requirements, it is necessary to develop a safety-critical (SIL 4) grade safety display system. This paper proposes industrial personal computer based safety display system with safety grade operating system and safety grade display methods. The description consists of three parts, the background, the safety requirements and the proposed safety display system design. The hardware platform is designed using commercially available off-the-shelf processor board with back plane bus. The operating system is customized for nuclear safety display application. The display unit is designed adopting two improvement features, i.e., one is to provide two separate processors for main computer and display device using serial communication, and the other is to use Digital Visual Interface between main computer and display device. In this case the main computer uses minimized graphic functions for safety display. The display design is at the conceptual phase, and there are several open areas to be concreted for a solid system. The main purpose of this paper is to describe and suggest a methodology to develop a safety-critical display system and the descriptions are focused on the safety requirement point of view

  17. Industrial Personal Computer based Display for Nuclear Safety System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hyeon; Kim, Aram; Jo, Jung Hee; Kim, Ki Beom; Cheon, Sung Hyun; Cho, Joo Hyun; Sohn, Se Do; Baek, Seung Min [KEPCO, Youngin (Korea, Republic of)

    2014-08-15

    The safety display of nuclear system has been classified as important to safety (SIL:Safety Integrity Level 3). These days the regulatory agencies are imposing more strict safety requirements for digital safety display system. To satisfy these requirements, it is necessary to develop a safety-critical (SIL 4) grade safety display system. This paper proposes industrial personal computer based safety display system with safety grade operating system and safety grade display methods. The description consists of three parts, the background, the safety requirements and the proposed safety display system design. The hardware platform is designed using commercially available off-the-shelf processor board with back plane bus. The operating system is customized for nuclear safety display application. The display unit is designed adopting two improvement features, i.e., one is to provide two separate processors for main computer and display device using serial communication, and the other is to use Digital Visual Interface between main computer and display device. In this case the main computer uses minimized graphic functions for safety display. The display design is at the conceptual phase, and there are several open areas to be concreted for a solid system. The main purpose of this paper is to describe and suggest a methodology to develop a safety-critical display system and the descriptions are focused on the safety requirement point of view.

  18. High level organizing principles for display of systems fault information for commercial flight crews

    Science.gov (United States)

    Rogers, William H.; Schutte, Paul C.

    1993-01-01

    Advanced fault management aiding concepts for commercial pilots are being developed in a research program at NASA Langley Research Center. One aim of this program is to re-evaluate current design principles for display of fault information to the flight crew: (1) from a cognitive engineering perspective and (2) in light of the availability of new types of information generated by advanced fault management aids. The study described in this paper specifically addresses principles for organizing fault information for display to pilots based on their mental models of fault management.

  19. Recent progress in OLED and flexible displays and their potential for application to aerospace and military display systems

    Science.gov (United States)

    Sarma, Kalluri

    2015-05-01

    Organic light emitting diode (OLED) display technology has advanced significantly in recent years and it is increasingly being adapted in consumer electronics products with premium performance, such as high resolution smart phones, Tablet PCs and TVs. Even flexible OLED displays are beginning to be commercialized in consumer electronic devices such as smart phones and smart watches. In addition to the advances in OLED emitters, successful development and adoption of OLED displays for premium performance applications relies on the advances in several enabling technologies including TFT backplanes, pixel drive electronics, pixel patterning technologies, encapsulation technologies and system level engineering. In this paper we will discuss the impact of the recent advances in LTPS and AOS TFTs, R, G, B and White OLED with color filter pixel architectures, and encapsulation, on the success of the OLEDs in consumer electronic devices. We will then discuss potential of these advances in addressing the requirements of OLED and flexible displays for the military and avionics applications.

  20. PRE-SERVICE MATHEMATICS TEACHERS’ CONCEPTION OF HIGHER-ORDER THINKING LEVEL IN BLOOM'S TAXONOMY

    OpenAIRE

    Damianus D Samo

    2017-01-01

    The purpose of this study is to explore pre-service mathematics teachers' conception of higher-order thinking in Bloom's Taxonomy, to explore pre-service mathematics teachers' ability in categorizing six cognitive levels of Bloom's Taxonomy as lower-order thinking and higher-order thinking, and pre-service mathematics teachers' ability in identifying some questionable items as lower-order and higher-order thinking. The higher-order thinking is the type of non-algorithm thinking which include ...

  1. Toward optimal color image quality of television display

    Science.gov (United States)

    MacDonald, Lindsay W.; Endrikhovski, Sergej N.; Bech, Soren; Jensen, Kaj

    1999-12-01

    A general framework and first experimental results are presented for the `OPTimal IMage Appearance' (OPTIMA) project, which aims to develop a computational model for achieving optimal color appearance of natural images on adaptive CRT television displays. To achieve this goal we considered the perceptual constraints determining quality of displayed images and how they could be quantified. The practical value of the notion of optimal image appearance was translated from the high level of the perceptual constraints into a method for setting the display's parameters at the physical level. In general, the whole framework of quality determination includes: (1) evaluation of perceived quality; (2) evaluation of the individual perceptual attributes; and (3) correlation between the physical measurements, psychometric parameters and the subjective responses. We performed a series of psychophysical experiments, with observers viewing a series of color images on a high-end consumer television display, to investigate the relationships between Overall Image Quality and four quality-related attributes: Brightness Rendering, Chromatic Rendering, Visibility of Details and Overall Naturalness. The results of the experiments presented in this paper suggest that these attributes are highly inter-correlated.

  2. On a "Level-Sensitive" Headcount Ratio: Revisiting Shorrocks' Poverty Index

    Science.gov (United States)

    Subramanian, Sreenivasan

    2008-01-01

    It is often argued that indicators of achievement or deprivation should be measured such that they display a property of "level-sensitivity", whereby a given change in the indicator acquires a greater significance the higher (lower) the level of achievement (deprivation) at which the change occurs. In this note, it is shown that a level-sensitive…

  3. Software Development for Remote Control and Firing Room Displays

    Science.gov (United States)

    Zambrano Pena, Jessica

    2014-01-01

    The Launch Control System (LCS) developed at NASA's Kennedy Space Center (KSC) will be used to launch future spacecraft. Two of the many components of this system are the Application Control Language (ACL) and remote displays. ACL is a high level domain specific language that is used to write remote control applications for LCS. Remote displays are graphical user interfaces (GUIs) developed to display vehicle and Ground Support Equipment (GSE) data, they also provide the ability to send commands to control GSE and the vehicle. The remote displays and the control applications have many facets and this internship experience dealt with several of them.

  4. Late Holocene higher sea level and its radiocarbon dates in Okierabu-jima, Ryukyus

    International Nuclear Information System (INIS)

    Koba, Motoharu; Omoto, Kunio; Takahashi, Tatsuo.

    1980-01-01

    Okierabu-jima of the Ryukyu Islands, which is a poly-terraced Pleistocene raised coral reef island, doesn't have a Holocene raised coral reef, but coastal erosional features showing higher sea levels in Holocene. The authors obtained some data indicating the period of one of the Holocene higher sea levels. All radiocarbon dates concerning Okierabu-jima's Holocene sea-level changes are plotted on the date-height coordinates. The paleo sea level between 5000 and 2000 y. B. P. lies above the broken line drawn from 6 m below to 2.18 m above the present sea level. The period of the highest sea level in Holocene seems to be about 3000 to 2000 y. B. P. in this island. Its height is presumably 2.4 m a. s. l. derived on an average from heights of stacks and coastal benches in the almost all coasts of the island (Koba, 1974). Beach rocks were already formed at the landward extremity of the reef flat corresponding to the almost present sea level about 1300 y. B. P. (author)

  5. Higher glucose levels associated with lower memory and reduced hippocampal microstructure.

    Science.gov (United States)

    Kerti, Lucia; Witte, A Veronica; Winkler, Angela; Grittner, Ulrike; Rujescu, Dan; Flöel, Agnes

    2013-11-12

    For this cross-sectional study, we aimed to elucidate whether higher glycosylated hemoglobin (HbA1c) and glucose levels exert a negative impact on memory performance and hippocampal volume and microstructure in a cohort of healthy, older, nondiabetic individuals without dementia. In 141 individuals (72 women, mean age 63.1 years ± 6.9 SD), memory was tested using the Rey Auditory Verbal Learning Test. Peripheral levels of fasting HbA1c, glucose, and insulin and 3-tesla MRI scans were acquired to assess hippocampal volume and microstructure, as indicated by gray matter barrier density. Linear regression and simple mediation models were calculated to examine associations among memory, glucose metabolism, and hippocampal parameters. Lower HbA1c and glucose levels were significantly associated with better scores in delayed recall, learning ability, and memory consolidation. In multiple regression models, HbA1c remained strongly associated with memory performance. Moreover, mediation analyses indicated that beneficial effects of lower HbA1c on memory are in part mediated by hippocampal volume and microstructure. Our results indicate that even in the absence of manifest type 2 diabetes mellitus or impaired glucose tolerance, chronically higher blood glucose levels exert a negative influence on cognition, possibly mediated by structural changes in learning-relevant brain areas. Therefore, strategies aimed at lowering glucose levels even in the normal range may beneficially influence cognition in the older population, a hypothesis to be examined in future interventional trials.

  6. Display Sharing: An Alternative Paradigm

    Science.gov (United States)

    Brown, Michael A.

    2010-01-01

    The current Johnson Space Center (JSC) Mission Control Center (MCC) Video Transport System (VTS) provides flight controllers and management the ability to meld raw video from various sources with telemetry to improve situational awareness. However, maintaining a separate infrastructure for video delivery and integration of video content with data adds significant complexity and cost to the system. When considering alternative architectures for a VTS, the current system's ability to share specific computer displays in their entirety to other locations, such as large projector systems, flight control rooms, and back supporting rooms throughout the facilities and centers must be incorporated into any new architecture. Internet Protocol (IP)-based systems also support video delivery and integration. IP-based systems generally have an advantage in terms of cost and maintainability. Although IP-based systems are versatile, the task of sharing a computer display from one workstation to another can be time consuming for an end-user and inconvenient to administer at a system level. The objective of this paper is to present a prototype display sharing enterprise solution. Display sharing is a system which delivers image sharing across the LAN while simultaneously managing bandwidth, supporting encryption, enabling recovery and resynchronization following a loss of signal, and, minimizing latency. Additional critical elements will include image scaling support, multi -sharing, ease of initial integration and configuration, integration with desktop window managers, collaboration tools, host and recipient controls. This goal of this paper is to summarize the various elements of an IP-based display sharing system that can be used in today's control center environment.

  7. Display-And-Alarm Circuit For Accelerometer

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Compact accelerometer assembly consists of commercial accelerometer retrofit with display-and-alarm circuit. Provides simple means for technician attending machine to monitor vibrations. Also simpifies automatic safety shutdown by providing local alarm or shutdown signal when vibration exceeds preset level.

  8. Testing the deGroot recall paradigm to evaluate displays for operating personnel

    International Nuclear Information System (INIS)

    Moray, N.; Jones, B.G.; Rasmussen, J.

    1991-01-01

    In this paper the authors report the results of experiments based on deGroot's work to assess the value of memory tests for measuring the quality of displays and the level of expertise of operators. Three kinds of display and people with three levels of expertise were included in the experiments. The displays were computer generated versions of traditional analog meters, traditional analog meters supplemented by a dynamic graphic representing the relation between temperature and pressure in some subsystems, and a dynamic graphic representing the underlying thermodynamics of power generation using the Rankine Cycle. The levels of expertise were represented by undergraduates with one semester of thermodynamics, graduate students of thermodynamics and nuclear engineering, and professional nuclear power plant operators. Each group watched a set of transients presented on the displays, using data generated by a high fidelity NPP training simulator, and were then asked three kinds of questions. The first measured their ability to recall the exact values of system state variables. The second measured their ability to recall what qualitative states the system had entered during the transient. The third measured their ability diagnose the nature of the transient. The results of the experiments are reported in relation to the possible use of memory tests to evaluate displays and the interaction of the quality of displays with the level of expertise of operators

  9. Market trends in the projection display industry

    Science.gov (United States)

    Dash, Sweta

    2000-04-01

    The projection display industry represents a multibillion- dollar market that includes four distinct technologies. High-volume consumer products and high-value business products drive the market, with different technologies being used in different application markets. The consumer market is dominated by rear CRT technology, especially in the projection television segment. But rear LCD (liquid crystal display) and rear reflective (DLP, or Digital Light ProcessingTM) televisions are slowly emerging as future competitors to rear CRT projectors. Front CRT projectors are still popular in the high-end home theater market. Front LCD technology and front DLP technology dominate the business market. Traditional light valve technology was the only solution for applications requiring high light outputs, but new three-chip DLP projectors meet the higher light output requirements at a lower price. In the last few years the strongest growth has been in the business market for multimedia presentation applications. This growth was due to the continued increase in display pixel formats, the continued reduction in projector weight, and the improved price/performance ratio. The projection display market will grow at a significant rate during the next five years, driven by the growth in ultraportable (market to digital and HDTV products.

  10. Factors identified with higher levels of career satisfaction of physicians in Andalusia, Spain

    Directory of Open Access Journals (Sweden)

    Juan Nicolás Peña-Sánchez

    2014-09-01

    Full Text Available The satisfaction of physicians is a world-wide issue linked with the quality of health services; their satisfaction needs to be studied from a multi-dimensional perspective, considering lower- and higher-order needs. The objectives of this study were to: i measure the career satisfaction of physicians; ii identify differences in the dimensions of career satisfaction; and iii test factors that affect higher- and lower-order needs of satisfaction among physicians working in Andalusian hospitals (Spain. Forty-one percent of 299 eligible physicians participated in a study conducted in six selected hospitals. Physicians reported higher professional, inherent, and performance satisfaction than personal satisfaction. Foreign physicians reported higher levels of personal and performance satisfaction than local physicians, and those who received non-monetary incentives had higher professional and performance satisfaction. In conclusion, physicians in the selected Andalusian hospitals reported low levels of personal satisfaction. Non-monetary incentives were more relevant to influence their career satisfaction. Further investigations are recommended to study differences in the career satisfaction between foreign and local physicians.

  11. Invisible Display in Aluminum

    DEFF Research Database (Denmark)

    Prichystal, Jan Phuklin; Hansen, Hans Nørgaard; Bladt, Henrik Henriksen

    2005-01-01

    Bang & Olufsen a/s has been working with ideas for invisible integration of displays in metal surfaces. Invisible integration of information displays traditionally has been possible by placing displays behind transparent or semitransparent materials such as plastic or glass. The wish for an integ......Bang & Olufsen a/s has been working with ideas for invisible integration of displays in metal surfaces. Invisible integration of information displays traditionally has been possible by placing displays behind transparent or semitransparent materials such as plastic or glass. The wish...... for an integrated display in a metal surface is often ruled by design and functionality of a product. The integration of displays in metal surfaces requires metal removal in order to clear the area of the display to some extent. The idea behind an invisible display in Aluminum concerns the processing of a metal...

  12. Intake of Lutein-Rich Vegetables Is Associated with Higher Levels of Physical Activity

    Directory of Open Access Journals (Sweden)

    Georgina Crichton

    2015-09-01

    Full Text Available Levels of physical inactivity, a major contributor to burden of disease, are high in many countries. Some preliminary research suggests that circulating lutein concentrations are associated with high levels of physical activity (PA. We aimed to assess whether the intake of lutein-containing foods, including vegetables and eggs, is associated with levels of PA in two studies conducted in different countries. Dietary data and PA data collected from participants in two cross-sectional studies: the Maine-Syracuse Longitudinal Study (MSLS, conducted in Central New York, USA (n = 972, and the Observation of Cardiovascular Risk Factors in Luxembourg Study (ORISCAV-LUX (n = 1331 were analyzed. Higher intakes of lutein containing foods, including green leafy vegetables, were associated with higher levels of PA in both study sites. Increasing the consumption of lutein-rich foods may have the potential to impact positively on levels of PA. This needs to be further explored in randomized controlled trials.

  13. Frequency of Gingival Display During Smiling and Comparison of Biometric Measurements in Subjects with and without Gingival Display

    International Nuclear Information System (INIS)

    Khan, F.; Abbas, M.

    2014-01-01

    Objective: To determine the frequency of gingival display during smiling and to compare biometric measurements in subjects with and without gingival display. Study Design: Cross-sectional study. Place and Duration of Study: Department of Prosthodontics, Dr. Ishrat-ul-Ibad Khan Institute of Oral Health Sciences, Dow University of Health Sciences, Karachi, from October 2012 to March 2013. Methodology: A total of 275 subjects (121 men and 154 women) were included in this study. The age of the participants ranged between 21 and 65 years. Measurements were carried out using digital caliper. For each participants, the gingival display was judged as either visible or not. The amounts of horizontal and vertical overlap of anterior teeth were measured using a digital caliper. Gender differences in these parameters and the relationship between subjects showing gingival display when smiling and the two intraoral dental biometric measurements were determined. Statistical analyses of data were performed using SPSS version 17.0 software. The mean scores for gender were calculated and a Student's t-test was used to identify significant differences between both groups. Significant level was set to 0.05. Results: A relatively small percentage of the subjects (37.8%) displayed gingiva when smiling. More women significantly displayed gingiva when smiling than men, with a 2:1 female: male ratio. Women had significantly (p=0.001) more horizontal overlap (3.34 +- 1.45 mm) than men (2.90 +- 1.44 mm), although no significant gender difference were found in vertical overlap. Subjects with gingival display had significantly (p < 0.05) more horizontal (3.49 +- 1.36 mm) and vertical (3.26 +- 1.47 mm) overlap of anterior teeth compared to those who did not display gingiva when smiling. Conclusion: Significantly more women displayed gingiva in smiling. Women had significantly more horizontal overlap than men. No gender differences were recorded between vertical overlap. Subjects who displayed

  14. Teaching at higher levels

    Science.gov (United States)

    1998-11-01

    Undergraduate physics programmes for the 21st century were under discussion at a recent event held in Arlington, USA, open to two or three members of the physics faculties of universities from across the whole country. The conference was organized by the American Association of Physics Teachers with co-sponsorship from the American Institute of Physics, the American Physical Society and Project Kaleidoscope. Among the various aims were to learn about physics departments that have successfully revitalized their undergraduate physics programmes with innovative introductory physics courses and multi-track majors programmes. Engineers and life scientists were to be asked directly how physics programmes can better serve their students, and business leaders would be speaking on how physics departments can help to prepare their students for the diverse careers that they will eventually follow. It was planned to highlight ways that departments could fulfil their responsibilities towards trainee teachers, to identify the resources needed for revitalizing a department's programme, and to develop guidelines and recommendations for a funding programme to support collaborative efforts among physics departments for carrying out the enhancements required. More details about the conference can be found on the AAPT website (see http://www.aapt.org/programs/rupc.html). Meanwhile the UK's Higher Education Funding Council has proposed a two-pronged approach to the promotion of high quality teaching and learning, as well as widening participation in higher education from 1999-2000. A total of £60m should be available to support these initiatives by the year 2001-2002. As part of this scheme the Council will invite bids from institutions to support individual academics in enhancing learning and teaching, as well as in recognition of individual excellence. As with research grants, such awards would enable staff to pursue activities such as the development of teaching materials

  15. Natural display mode for digital DICOM-conformant diagnostic imaging.

    Science.gov (United States)

    Peters, Klaus-Ruediger; Ramsby, Gale R

    2002-09-01

    The authors performed this study to investigate the verification of the contrast display properties defined by the digital imaging and communication in medicine (DICOM) PS (picture archiving and communication system [PACS] standard) 3.14-2001 gray-scale display function standard and their dependency on display luminance range and video signal bandwidth. Contrast sensitivity and contrast linearity of DICOM-conformant displays were measured in just-noticeable differences (JNDs) on special perceptual contrast test patterns. Measurements were obtained six times at various display settings under dark room conditions. Display luminance range and video bandwidth had a significant effect on contrast perception. The perceptual promises of the standard could be established only with displays that were calibrated to a unity contrast resolution, at which the number of displayed intensity steps was equal to the number of perceivable contrast steps (JNDs). Such display conditions provide for visual perception information at the level of single-step contrast sensitivity and full-range contrast linearity. These "natural display" conditions also help minimize the Mach banding effects that otherwise reduce contrast sensitivity and contrast linearity. Most, if not all, conventionally used digital display modalities are driven with a contrast resolution larger than 1. Such conditions reduce contrast perception when compared with natural imaging conditions. The DICOM-conformant display conditions at unity contrast resolution were characterized as the "natural display" mode, and, thus, the authors a priori recommend them as being useful for making a primary diagnosis with PACS and teleradiology and as a standard for psychophysical research and performance measurements.

  16. Management of excessive gingival display: Lip repositioning technique

    Directory of Open Access Journals (Sweden)

    Upasana Sthapak

    2015-01-01

    Full Text Available The lips form the frame of a smile and define the esthetic zone. Excessive gingival display during smile is often referred to as "gummy smile". A successful management of excessive gingival display with lip repositioning procedure has shown excellent results. The procedure involves removing a strip of partial thickness mucosa from maxillary vestibule, then suturing it back to the lip mucosa at the level of mucogingival junction. This technique results in restricted muscle pull and a narrow vestibule, thereby reducing the gingival display. In this case gummy smile was treated by modification of Rubinstein and Kostianovsky′s surgical lip repositioning technique which resulted in a harmonious smile.

  17. Process-oriented guided inquiry learning strategy enhances students' higher level thinking skills in a pharmaceutical sciences course.

    Science.gov (United States)

    Soltis, Robert; Verlinden, Nathan; Kruger, Nicholas; Carroll, Ailey; Trumbo, Tiffany

    2015-02-17

    To determine if the process-oriented guided inquiry learning (POGIL) teaching strategy improves student performance and engages higher-level thinking skills of first-year pharmacy students in an Introduction to Pharmaceutical Sciences course. Overall examination scores and scores on questions categorized as requiring either higher-level or lower-level thinking skills were compared in the same course taught over 3 years using traditional lecture methods vs the POGIL strategy. Student perceptions of the latter teaching strategy were also evaluated. Overall mean examination scores increased significantly when POGIL was implemented. Performance on questions requiring higher-level thinking skills was significantly higher, whereas performance on questions requiring lower-level thinking skills was unchanged when the POGIL strategy was used. Student feedback on use of this teaching strategy was positive. The use of the POGIL strategy increased student overall performance on examinations, improved higher-level thinking skills, and provided an interactive class setting.

  18. Advanced Colorimetry of Display Systems: Tetra-Chroma3 Display Unit

    Directory of Open Access Journals (Sweden)

    J. Kaiser

    2005-06-01

    Full Text Available High-fidelity color image reproduction is one of the key issues invisual telecommunication systems, for electronic commerce,telemedicine, digital museum and so on. All colorimetric standards ofdisplay systems are up to the present day trichromatic. But, from theshape of a horseshoe-area of all existing colors in the CIE xychromaticity diagram it follows that with three real reproductivelights, the stated area in the CIE xy chromaticity diagram cannot beoverlaid. The expansion of the color gamut of a display device ispossible in a few ways. In this paper, the way of increasing the numberof primaries is studied. The fourth cyan primary is added to threeconventional ones to enlarge the color gamut of reproduction towardscyans and yellow-oranges. The original method of color management forthis new display unit is introduced. In addition, the color gamut ofthe designed additive-based display is successfully compared with thecolor gamut of a modern subtractive-based system. A display with morethan three primary colors is called a multiprimary color display. Thevery advantageous property of such display is the possibility todisplay metameric colors.

  19. Extension of TFTR operations to higher toroidal field levels

    International Nuclear Information System (INIS)

    Woolley, R.D.

    1995-01-01

    For the past year, TFTR has sometimes operated at extended toroidal field (TF) levels. The extension to 5.6 Tesla (79 kA) was crucial for TFTR's November 1994 10.7 MW DT fusion power record. The extension to 6.0 Tesla (85 kA) was commissioned on 9 September 1995. There are several reasons that one could expect the TF coils to survive the higher stresses that develop at higher fields. They were designed to operate at 5.2 Tesla with a vertical field of 0.5 Tesla, whereas the actual vertical field needed for the plasma does not exceed 0.35 Tesla. Their design specification explicitly required they survive some pulses at 6.0 Tesla. TF coil mechanical analysis computer models available during coil design were crude, leading to conservative design. And design analyses also had to consider worst-case misoperations that TFTR's real time Coil Protection Calculators (CPCs) now positively prevent from occurring

  20. Factors associated with higher levels of depressive symptoms among international university students in the Philippines.

    Science.gov (United States)

    Lee, Romeo B; Maria, Madelene Sta; Estanislao, Susana; Rodriguez, Cristina

    2013-11-01

    Over the years, the number of international university students has been increasing in the Philippines. Depression tends to be common among this demographic sector, because of the varying challenges and expectations associated with studying abroad. Depression can be prevented if its symptoms, particularly those at higher levels, are identified and addressed early and effectively. This survey examined the social and demographic factors that are significantly associated with higher levels of depressive symptoms. One hundred twenty-six international university students were interviewed using the University Students Depression Inventory. Of the 13 factors analyzed, 3 were found with statistically significant associations with more intense levels of depressive symptoms. These factors were: level of satisfaction with one's financial condition, level of closeness with parents, and level of closeness with peers. In identifying international students with greater risk for depression, characteristics related to their financial condition and primary group relationships can be considered. There is a need to carry out more studies to confirm this initial evidence. The findings can help guide further discourse, research and program to benefit international students with higher levels of depressive symptoms.

  1. 72-directional display having VGA resolution for high-appearance image generation

    Science.gov (United States)

    Takaki, Yasuhiro; Dairiki, Takeshi

    2006-02-01

    The high-density directional display, which was originally developed in order to realize a natural 3D display, is not only a 3D display but also a high-appearance display. The appearances of objects, such as glare and transparency, are the results of the reflection and the refraction of rays. The faithful reproduction of such appearances of objects is impossible using conventional 2D displays because rays diffuse on the display screen. The high-density directional display precisely controls the horizontal ray directions so that it can reproduce the appearances of objects. The fidelity of the reproduction of object appearances depends on the ray angle sampling pitch. The angle sampling pitch is determined by considering the human eye imaging system. In the present study the high-appearance display which has the resolution of 640×400 and emits rays in 72 different horizontal directions with the angle pitch of 0.38° was constructed. Two 72-directional displays were combined, each of which consisted of a high-resolution LCD panel (3,840×2,400) and a slanted lenticular sheet. Two images produced by two displays were superimposed by a half mirror. A slit array was placed at the focal plane of the lenticular sheet for each display to reduce the horizontal image crosstalk in the combined image. The impression analysis shows that the high-appearance display provides higher appearances and presence than the conventional 2D displays do.

  2. Hazard Quotients, Hazard Indexes, and Cancer Risks of Toxic Metals in PM10 during Firework Displays

    Directory of Open Access Journals (Sweden)

    Siwatt Pongpiachan

    2018-04-01

    Full Text Available Bonfire night is a worldwide phenomenon given to numerous annual celebrations characterised by bonfires and fireworks. Since Thailand has no national ambient air quality standards for metal particulates, it is important to investigate the impacts of particulate injections on elevations of air pollutants and the ecological health impacts resulting from firework displays. In this investigation, Pb and Ba were considered potential firework tracers because their concentrations were significantly higher during the episode, and lower than/comparable with minimum detection limits during other periods, indicating that their elevated concentrations were principally due to pyrotechnic displays. Pb/Ca, Pb/Al, Pb/Mg, and Pb/Cu can be used to pin-point emissions from firework displays. Air mass backward trajectories (72 h from the Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT model indicated that areas east and north-east of the study site were the main sources of the airborne particles. Although the combined risk associated with levels of Pb, Cr, Co., Ni, Zn, As, Cd, V, and Mn was far below the standards mentioned in international guidelines, the lifetime cancer risks associated with As and Cr levels exceeded US-EPA guidelines, and may expose inhabitants of surrounding areas of Bangkok to an elevated cancer risk.

  3. Process-Oriented Guided Inquiry Learning Strategy Enhances Students’ Higher Level Thinking Skills in a Pharmaceutical Sciences Course

    Science.gov (United States)

    Verlinden, Nathan; Kruger, Nicholas; Carroll, Ailey; Trumbo, Tiffany

    2015-01-01

    Objective. To determine if the process-oriented guided inquiry learning (POGIL) teaching strategy improves student performance and engages higher-level thinking skills of first-year pharmacy students in an Introduction to Pharmaceutical Sciences course. Design. Overall examination scores and scores on questions categorized as requiring either higher-level or lower-level thinking skills were compared in the same course taught over 3 years using traditional lecture methods vs the POGIL strategy. Student perceptions of the latter teaching strategy were also evaluated. Assessment. Overall mean examination scores increased significantly when POGIL was implemented. Performance on questions requiring higher-level thinking skills was significantly higher, whereas performance on questions requiring lower-level thinking skills was unchanged when the POGIL strategy was used. Student feedback on use of this teaching strategy was positive. Conclusion. The use of the POGIL strategy increased student overall performance on examinations, improved higher-level thinking skills, and provided an interactive class setting. PMID:25741027

  4. Performance analysis of multi-primary color display based on OLEDs/PLEDs

    Science.gov (United States)

    Xiong, Yan; Deng, Fei; Xu, Shan; Gao, Shufang

    2017-09-01

    A multi-primary color display, such as the six-primary color format, is a solution in expanding the color gamut of a full-color flat panel display. The performance of a multi-primary color display based on organic/polymer light-emitting diodes was analyzed in this study using the fitting curves of the characteristics of devices (i.e., current density, voltage, luminance). A white emitter was introduced into a six-primary color format to form a seven-primary color format that contributes to energy saving, and the ratio of power efficiency of a seven-primary color display to that of a six-primary color display would increase from 1.027 to 1.061 by using emitting diodes with different electroluminescent efficiencies. Different color matching schemes of the seven-primary color format display were compared in a uniform color space, and the scheme of the color reproduction did not significantly affect the display performance. Although seven- and six-primary color format displays benefit a full-color display with higher quality, they are less efficient than three-primary (i.e., red (R), green (G), and blue (B), RGB) and four-primary (i.e., RGB+white, RGBW) color format displays. For the seven-primary color formats considered in this study, the advantages of white-primary-added display with efficiently developed light-emitting devices were more evident than the format without a white primary.

  5. Microlaser-based displays

    Science.gov (United States)

    Bergstedt, Robert; Fink, Charles G.; Flint, Graham W.; Hargis, David E.; Peppler, Philipp W.

    1997-07-01

    Laser Power Corporation has developed a new type of projection display, based upon microlaser technology and a novel scan architecture, which provides the foundation for bright, extremely high resolution images. A review of projection technologies is presented along with the limitations of each and the difficulties they experience in trying to generate high resolution imagery. The design of the microlaser based projector is discussed along with the advantage of this technology. High power red, green, and blue microlasers have been designed and developed specifically for use in projection displays. These sources, in combination with high resolution, high contrast modulator, produce a 24 bit color gamut, capable of supporting the full range of real world colors. The new scan architecture, which reduces the modulation rate and scan speeds required, is described. This scan architecture, along with the inherent brightness of the laser provides the fundamentals necessary to produce a 5120 by 4096 resolution display. The brightness and color uniformity of the display is excellent, allowing for tiling of the displays with far fewer artifacts than those in a traditionally tiled display. Applications for the display include simulators, command and control centers, and electronic cinema.

  6. Pride displays communicate self-interest and support for meritocracy.

    Science.gov (United States)

    Horberg, E J; Kraus, Michael W; Keltner, Dacher

    2013-07-01

    The present studies examined how observers infer moral attributes and beliefs from nonverbal pride displays. Pride is a self-focused positive emotion triggered by appraisals of the self's success, status, and competence. We hypothesized that when a target emits nonverbal cues of pride, he or she will be viewed by observers as higher in self-interest and therefore more likely to endorse ideologies that would benefit the self-specifically, merit-based resource distributions (meritocracy) as opposed to equality-based resource distributions (egalitarianism). Across studies, experimentally manipulated pride displays (Studies 1 and 3) and naturally occurring expressions of pride (Study 4) led observers to infer heightened support for meritocracy as opposed to egalitarianism. Analyses also revealed that people intuitively associate higher self-interest with enhanced support for meritocracy as opposed to egalitarianism (Study 2), and this association mediates the pathway from pride displays to inferences of heightened support for meritocracy and reduced support for egalitarianism (Studies 3 and 4). Across studies, we compare pride to expressions of joy or no emotion and demonstrate these effects using thin slices as well as static images. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  7. Function-oriented display system: background and first prototypes

    International Nuclear Information System (INIS)

    Andresen, Gisle; Friberg, Maarten; Teigen, Arild; Pirus, Dominique

    2004-04-01

    The objective of the function-oriented displays and alarm project is to design, implement and evaluate Human System Interfaces (HSI) based on a function-oriented design philosophy. Function-oriented design is an approach for designing HSIs where the plant's functions, identified through a function analysis, are used for determining the content, organisation, and management of displays. The project has used the 'FITNESS approach', originally developed by EDF in France, as a starting point. FITNESS provides an integrated display system consisting of process operating displays, operating procedures, alarms and trend displays - all based on a functional decomposition of the plant. So far, two prototypes have been implemented on the FRESH PWR simulator in HAMMLAB. The first prototype focused on the condensate pumps. Three process operating displays representing functions at different levels of the functional hierarchy were implemented. Computerised startup and shutdown procedures for the condensate pumps function were also implemented. In the second prototype, the scope was increased to cover the main feedwater system. The displays of the first prototype were redesigned and additional displays were created. In conclusion, the first phase of the project has been completed successfully, and we are now ready to enter the second phase. In the second phase, the scope of the prototype will be increased further to include the steam-generators and function-oriented disturbance operating procedures. The prototype will be evaluated in a user test conducted later in 2004. (Author)

  8. Experience with model based display for advanced diagnostics and control

    International Nuclear Information System (INIS)

    Staffon, J.D.; Lindsay, R.W.

    1989-01-01

    A full color, model based display system based on the Rankine thermodynamic cycle has been developed for use at the Experimental Breeder Reactor II by plant operators, engineers, and experimenters. The displays generate a real time thermodynamic model of the plant processes on computer screens to provide a direct indication of the plant performance. Operators and others who view the displays are no longer required to mentally ''construct'' a model of the process before acting. The model based display accurately depicts the plant states. It appears to effectively reduce the gulf of evaluation, which should result in a significant reduction in human operator errors if this plant display approach is adopted by the nuclear industry. Preliminary comments from users, including operators, indicate an overwhelming acceptance of the display approach. The displays incorporate alarm functions as well as levels of detail ''paging'' capability. The system is developed on a computer network which allows the easy addition of displays as well as extra computers. Constructing a complete console can be rapid and inexpensive. 1 ref., 2 figs

  9. Handbook of display technology

    CERN Document Server

    Castellano, Joseph A

    1992-01-01

    This book presents a comprehensive review of technical and commercial aspects of display technology. It provides design engineers with the information needed to select proper technology for new products. The book focuses on flat, thin displays such as light-emitting diodes, plasma display panels, and liquid crystal displays, but it also includes material on cathode ray tubes. Displays include a large number of products from televisions, auto dashboards, radios, and household appliances, to gasoline pumps, heart monitors, microwave ovens, and more.For more information on display tech

  10. Higher Levels of Psychopathy Predict Poorer Motor Control: Implications for Understanding the Psychopathy Construct

    OpenAIRE

    Robinson, Michael D.; Bresin, Konrad

    2014-01-01

    A review of the literature suggests that higher levels of psychopathy may be linked to less effective behavioral control. However, several commentators have urged caution in making statements of this type in the absence of direct evidence. In two studies (total N = 142), moment-to-moment accuracy in a motor control task was examined as a function of dimensional variations in psychopathy in an undergraduate population. As hypothesized, motor control was distinctively worse at higher levels of ...

  11. Liquid crystal display

    International Nuclear Information System (INIS)

    Takami, K.

    1981-01-01

    An improved liquid crystal display device is described which can display letters, numerals and other necessary patterns in the night time using a minimized amount of radioactive material. To achieve this a self-luminous light source is placed in a limited region corresponding to a specific display area. (U.K.)

  12. INFORMATION DISPLAY: CONSIDERATIONS FOR DESIGNING COMPUTER-BASED DISPLAY SYSTEMS

    International Nuclear Information System (INIS)

    O'HARA, J.M.; PIRUS, D.; BELTRATCCHI, L.

    2004-01-01

    This paper discussed the presentation of information in computer-based control rooms. Issues associated with the typical displays currently in use are discussed. It is concluded that these displays should be augmented with new displays designed to better meet the information needs of plant personnel and to minimize the need for interface management tasks (the activities personnel have to do to access and organize the information they need). Several approaches to information design are discussed, specifically addressing: (1) monitoring, detection, and situation assessment; (2) routine task performance; and (3) teamwork, crew coordination, collaborative work

  13. A qualitative study of users' engagement with real-time feedback from in-house energy consumption displays

    International Nuclear Information System (INIS)

    Oltra, Christian; Boso, Alex; Espluga, Josep; Prades, Ana

    2013-01-01

    Recent developments in feedback technologies and smart meters have advanced the introduction of energy consumption displays in the home. This could facilitate a significant amount of energy saving for the maximum number of homeowners. But empirical studies show that achieved savings in electricity consumption from in-house displays range approximately from 0 to 20%. In order to qualitatively explore the factors underlying such variation in the achieved saving, this paper studies how a small sample of householders interacted with the feedback from an energy consumption display. Following a heuristic model based on prior energy-related behavioral research, we explore the effects of the in-home display on household electricity. Results indicate that saving might be moderated by the level of user's engagement with the display, preceded by user's motivation to save energy, prior attitudes and, importantly, the level of involvement generated by the intervention. - Highlights: • We explore how householders interact with energy consumption displays. • Users' level of engagement with the display influence achieved savings. • User's motivation, level of involvement and prior attitudes are key elements

  14. Higher Level Visual Cortex Represents Retinotopic, Not Spatiotopic, Object Location

    Science.gov (United States)

    Kanwisher, Nancy

    2012-01-01

    The crux of vision is to identify objects and determine their locations in the environment. Although initial visual representations are necessarily retinotopic (eye centered), interaction with the real world requires spatiotopic (absolute) location information. We asked whether higher level human visual cortex—important for stable object recognition and action—contains information about retinotopic and/or spatiotopic object position. Using functional magnetic resonance imaging multivariate pattern analysis techniques, we found information about both object category and object location in each of the ventral, dorsal, and early visual regions tested, replicating previous reports. By manipulating fixation position and stimulus position, we then tested whether these location representations were retinotopic or spatiotopic. Crucially, all location information was purely retinotopic. This pattern persisted when location information was irrelevant to the task, and even when spatiotopic (not retinotopic) stimulus position was explicitly emphasized. We also conducted a “searchlight” analysis across our entire scanned volume to explore additional cortex but again found predominantly retinotopic representations. The lack of explicit spatiotopic representations suggests that spatiotopic object position may instead be computed indirectly and continually reconstructed with each eye movement. Thus, despite our subjective impression that visual information is spatiotopic, even in higher level visual cortex, object location continues to be represented in retinotopic coordinates. PMID:22190434

  15. Consequences of moral Kohlberg´s moral development levels in higher education

    OpenAIRE

    Bordignon, Nelso Antonio

    2011-01-01

    Abstract Introduction. This article presents the results of a research work about the implications of Kohlberg´s moral development level in higher education. Objective. To identify the state of moral development among higher education teachers, departing from the orientation they give to their lives and to those of their students, and from what they think and say they do for their students´ moral education.With the results, an analysis is done in order to establish the impli...

  16. Investigating Student Choices in Performing Higher-Level Comprehension Tasks Using TED

    Science.gov (United States)

    Bianchi, Francesca; Marenzi, Ivana

    2016-01-01

    The current paper describes a first experiment in the use of TED talks and open tagging exercises to train higher-level comprehension skills, and of automatic logging of the student's actions to investigate the student choices while performing analytical tasks. The experiment took advantage of an interactive learning platform--LearnWeb--that…

  17. Heterologous expression of carcinoembryonic antigen in Lactococcus lactis via LcsB-mediated surface displaying system for oral vaccine development.

    Science.gov (United States)

    Zhang, Xiaowei; Hu, Shumin; Du, Xue; Li, Tiejun; Han, Lanlan; Kong, Jian

    2016-12-01

    Carcinoembryonic antigen (CEA) is an attractive target for immunotherapy because it is expressed minimally in normal tissue, but is overexpressed in a wide variety of malignant epithelial tissues. Lactic acid bacteria (LABs), widely used in food processes, are attractive candidates for oral vaccination. Thus, we examined whether LABs could be used as a live vaccine vector to deliver CEA antigen. CEA was cloned into an Escherichia coli/Lactococcus lactis shuttle vector pSEC:LEISS under the control of a nisin promoter. For displaying the CEA on the cell surface of the L. lactis strain, the anchor motif LcsB from the S-layer protein of Lactobacillus crispatus was fused with CEA. Intracellular and cell surface expression of the CEA-LcsB fusion was confirmed by western blot analysis. Significantly higher levels of CEA-specific secretory immunoglobulin A in the sera of mice were observed upon oral administration of strain cultures containing the CEA-LcsB fused protein. In addition, the CEA-LcsB antigen group showed a higher spleen index compared to the CEA antigen alone or negative control, demonstrating that surface-displayed CEA antigen could induce a higher immune response. These results provided the first evidence for displaying CEA antigen on the cell surfaces of LABs as oral vaccines against cancer or infectious diseases. Copyright © 2014. Published by Elsevier B.V.

  18. Scanning laser beam displays based on a 2D MEMS

    Science.gov (United States)

    Niesten, Maarten; Masood, Taha; Miller, Josh; Tauscher, Jason

    2010-05-01

    The combination of laser light sources and MEMS technology enables a range of display systems such as ultra small projectors for mobile devices, head-up displays for vehicles, wearable near-eye displays and projection systems for 3D imaging. Images are created by scanning red, green and blue lasers horizontally and vertically with a single two-dimensional MEMS. Due to the excellent beam quality of laser beams, the optical designs are efficient and compact. In addition, the laser illumination enables saturated display colors that are desirable for augmented reality applications where a virtual image is used. With this technology, the smallest projector engine for high volume manufacturing to date has been developed. This projector module has a height of 7 mm and a volume of 5 cc. The resolution of this projector is WVGA. No additional projection optics is required, resulting in an infinite focus depth. Unlike with micro-display projection displays, an increase in resolution will not lead to an increase in size or a decrease in efficiency. Therefore future projectors can be developed that combine a higher resolution in an even smaller and thinner form factor with increased efficiencies that will lead to lower power consumption.

  19. Subjective comparison of brightness preservation methods for local backlight dimming displays

    DEFF Research Database (Denmark)

    Korhonen, Jari; Mantel, Claire; Forchhammer, Søren

    2015-01-01

    Local backlight dimming is a popular technology in high quality Liquid Crystal Displays (LCDs). In those displays, the backlight is composed of contributions from several individually adjustable backlight segments, set at different backlight luminance levels in different parts of the screen, acco...

  20. Obese with higher FNDC5/Irisin levels have a better metabolic profile, lower lipopolysaccharide levels and type 2 diabetes risk.

    Science.gov (United States)

    Bonfante, Ivan Luiz Padilha; Chacon-Mikahil, Mara Patricia Traina; Brunelli, Diego Trevisan; Gáspari, Arthur Fernandes; Duft, Renata Garbellini; Oliveira, Alexandre Gabarra; Araujo, Tiago Gomes; Saad, Mario Jose Abdalla; Cavaglieri, Cláudia Regina

    2017-12-01

    Thus, the aim of this study was to compare if higher or smaller fibronectin type 3 domain-containing protein 5 (FNDC5)/irisin levels are associated with inflammatory and metabolic markers, caloric/macronutrient intake, physical fitness and type 2 diabetes mellitus (T2DM) risk in obese middle-aged men, and also to correlate all variables analyzed with FNDC5/irisin. On the basis of a cluster study, middle-aged obese men (IMC: 31.01 ± 1.64 kg/m2) were divided into groups of higher and smaller levels of FNDC5/irisin. The levels of leptin, resistin, adiponectin, tumor necrosis factor alpha (TNFα), interleukin 6 and 10 (IL6, IL10), lipopolysaccharide (LPS), glucose, insulin, glycated hemoglobin, insulin resistance and sensibility, lipid profile, risk of T2DM development, body composition, rest energy expenditure, caloric/macronutrient intake and physical fitness were measured. The higher FNDC5/ irisin group presented improved insulin sensibility (homeostasis model assessment - sensibility (HOMA-S) (p = 0.01) and QUICKI index (p risk of T2DM development (p = 0.02), tendency to decrease serum resistin (p = 0.08) and significant lower LPS levels (p = 0.02). Inverse correlations between FNDC5/irisin and body weight (r -0.46, p = 0.04), neck circumference (r -0.51, p = 0.02), free fat mass (r -0.49, p = 0.02), triglycerides (r -0.43, p = 0.05) and risk of developing T2DM (r -0.61, p = 0.04) were observed. These results suggest that higher FNDC5/irisin levels in obese middle-aged men are related to a better metabolic profile and lower risk of T2DM development and serum LPS, a potential inducer of insulin resistance.

  1. Digital Immigrants and Digital Natives: Learning Business Informatics at Higher Educational Level

    Directory of Open Access Journals (Sweden)

    Suša Dalia

    2014-09-01

    Full Text Available Background: The term digital natives refer to those born since the 1980s and have been growing up surrounded by technology. On the other hand, digital immigrants are born before 1980s and learned how to use technology later in life. Objectives: Goal of the paper is to explore attitudes of digital native students on the course of Business Informatics at higher educational institutions (HEIs, and to compare them with attitudes of digital immigrants. Methods/Approach: The survey was conducted in 2014 using the sample of first-year Business Informatics students from the Faculty of Economics and Business in Zagreb, Croatia. Results were compared with a research conducted in 1998. Results: In comparison to an earlier research, digital natives perceive their level of competency in the subject of Business Informatics before teaching practices much higher compared to digital immigrants. However, there is still an increase in digital native students’ level of competency in the subject before and after teaching practices. Conclusions: The research confirms a shift from digital immigrants to digital natives who show high level of interest for Business Informatics course topics and find its utility very high. However, constant improvement of delivering knowledge is needed in order to keep these high levels.

  2. Genes with stable DNA methylation levels show higher evolutionary conservation than genes with fluctuant DNA methylation levels.

    Science.gov (United States)

    Zhang, Ruijie; Lv, Wenhua; Luan, Meiwei; Zheng, Jiajia; Shi, Miao; Zhu, Hongjie; Li, Jin; Lv, Hongchao; Zhang, Mingming; Shang, Zhenwei; Duan, Lian; Jiang, Yongshuai

    2015-11-24

    Different human genes often exhibit different degrees of stability in their DNA methylation levels between tissues, samples or cell types. This may be related to the evolution of human genome. Thus, we compared the evolutionary conservation between two types of genes: genes with stable DNA methylation levels (SM genes) and genes with fluctuant DNA methylation levels (FM genes). For long-term evolutionary characteristics between species, we compared the percentage of the orthologous genes, evolutionary rate dn/ds and protein sequence identity. We found that the SM genes had greater percentages of the orthologous genes, lower dn/ds, and higher protein sequence identities in all the 21 species. These results indicated that the SM genes were more evolutionarily conserved than the FM genes. For short-term evolutionary characteristics among human populations, we compared the single nucleotide polymorphism (SNP) density, and the linkage disequilibrium (LD) degree in HapMap populations and 1000 genomes project populations. We observed that the SM genes had lower SNP densities, and higher degrees of LD in all the 11 HapMap populations and 13 1000 genomes project populations. These results mean that the SM genes had more stable chromosome genetic structures, and were more conserved than the FM genes.

  3. Higher TSH Levels Within the Normal Range Are Associated With Unexplained Infertility.

    Science.gov (United States)

    Orouji Jokar, Tahereh; Fourman, Lindsay T; Lee, Hang; Mentzinger, Katherine; Fazeli, Pouneh K

    2018-02-01

    Unexplained infertility (UI), defined as the inability to conceive after 12 months of unprotected intercourse with no diagnosed cause, affects 10% to 30% of infertile couples. An improved understanding of the mechanisms underlying UI could lead to less invasive and less costly treatment strategies. Abnormalities in thyroid function and hyperprolactinemia are well-known causes of infertility, but whether thyrotropin (TSH) and prolactin levels within the normal range are associated with UI is unknown. To compare TSH and prolactin levels in women with UI and women with a normal fertility evaluation except for an azoospermic or severely oligospermic male partner. Cross-sectional study including women evaluated at a large academic health system between 1 January 2000 and 31 December 2012 with normal TSH (levels within the normal range of the assay and ≤5 mIU/L) and normal prolactin levels (≤20 ng/mL) and either UI (n = 187) or no other cause of infertility other than an azoospermic or severely oligospermic partner (n = 52). TSH and prolactin. Women with UI had significantly higher TSH levels than controls [UI: TSH 1.95 mIU/L, interquartile range: (1.54, 2.61); severe male factor: TSH 1.66 mIU/L, interquartile range: (1.25, 2.17); P = 0.003]. This finding remained significant after we controlled for age, body mass index, and smoking status. Nearly twice as many women with UI (26.9%) had a TSH ≥2.5 mIU/L compared with controls (13.5%; P < 0.05). Prolactin levels did not differ between the groups. Women with UI have higher TSH levels compared with a control population. More studies are necessary to determine whether treatment of high-normal TSH levels decreases time to conception in couples with UI. Copyright © 2017 Endocrine Society

  4. Evaluation of viewing experiences induced by a curved three-dimensional display

    Science.gov (United States)

    Mun, Sungchul; Park, Min-Chul; Yano, Sumio

    2015-10-01

    Despite an increased need for three-dimensional (3-D) functionality in curved displays, comparisons pertinent to human factors between curved and flat panel 3-D displays have rarely been tested. This study compared stereoscopic 3-D viewing experiences induced by a curved display with those of a flat panel display by evaluating subjective and objective measures. Twenty-four participants took part in the experiments and viewed 3-D content with two different displays (flat and curved 3-D display) within a counterbalanced and within-subject design. For the 30-min viewing condition, a paired t-test showed significantly reduced P300 amplitudes, which were caused by engagement rather than cognitive fatigue, in the curved 3-D viewing condition compared to the flat 3-D viewing condition at P3 and P4. No significant differences in P300 amplitudes were observed for 60-min viewing. Subjective ratings of realness and engagement were also significantly higher in the curved 3-D viewing condition than in the flat 3-D viewing condition for 30-min viewing. Our findings support that curved 3-D displays can be effective for enhancing engagement among viewers based on specific viewing times and environments.

  5. IMDISP - INTERACTIVE IMAGE DISPLAY PROGRAM

    Science.gov (United States)

    Martin, M. D.

    1994-01-01

    screen at once, the image can be "subsampled." For example, if the image were subsampled by a factor of 2, every other pixel from every other line would be displayed, starting from the upper left corner of the image. Any positive integer may be used for subsampling. The user may produce a histogram of an image file, which is a graph showing the number of pixels per DN value, or per range of DN values, for the entire image. IMDISP can also plot the DN value versus pixels along a line between two points on the image. The user can "stretch" or increase the contrast of an image by specifying low and high DN values; all pixels with values lower than the specified "low" will then become black, and all pixels higher than the specified "high" value will become white. Pixels between the low and high values will be evenly shaded between black and white. IMDISP is written in a modular form to make it easy to change it to work with different display devices or on other computers. The code can also be adapted for use in other application programs. There are device dependent image display modules, general image display subroutines, image I/O routines, and image label and command line parsing routines. The IMDISP system is written in C-language (94%) and Assembler (6%). It was implemented on an IBM PC with the MS DOS 3.21 operating system. IMDISP has a memory requirement of about 142k bytes. IMDISP was developed in 1989 and is a copyrighted work with all copyright vested in NASA. Additional planetary images can be obtained from the National Space Science Data Center at (301) 286-6695.

  6. Liquid Crystal Airborne Display

    Science.gov (United States)

    1977-08-01

    Cum.nings, J. P., et al., Properties and Limitations oe Liquid Crystals for Aircraft Displays, Honeywell Corporate Researc ."I Center, Final Report HR-72...basic module could be used to build displays for both the commercial and military! 157- marhecs, and so would establi sh a broad and sizable market ... market for the display becomes a reality; therein lies, f TABLE 16 THE COURSE OF FUTURE DISPLAY DEVELOPMENT Today 1976-77 1980 1985 Display Size 2" 1 3.2

  7. Evaluation of an organic light-emitting diode display for precise visual stimulation.

    Science.gov (United States)

    Ito, Hiroyuki; Ogawa, Masaki; Sunaga, Shoji

    2013-06-11

    A new type of visual display for presentation of a visual stimulus with high quality was assessed. The characteristics of an organic light-emitting diode (OLED) display (Sony PVM-2541, 24.5 in.; Sony Corporation, Tokyo, Japan) were measured in detail from the viewpoint of its applicability to visual psychophysics. We found the new display to be superior to other display types in terms of spatial uniformity, color gamut, and contrast ratio. Changes in the intensity of luminance were sharper on the OLED display than those on a liquid crystal display. Therefore, such OLED displays could replace conventional cathode ray tube displays in vision research for high quality stimulus presentation. Benefits of using OLED displays in vision research were especially apparent in the fields of low-level vision, where precise control and description of the stimulus are needed, e.g., in mesopic or scotopic vision, color vision, and motion perception.

  8. Off-line data processing and display for computed tomographic images (EMI brain)

    International Nuclear Information System (INIS)

    Takizawa, Masaomi; Maruyama, Kiyoshi; Yano, Kesato; Takenaka, Eiichi.

    1978-01-01

    Processing and multi-format display for the CT (EMI) scan data have been tried by using an off-line small computer and an analog memory. Four or six CT images after processing are displayed on the CRT by a small computer with a 16 kilo-words core memory and an analog memory. Multi-format display of the CT image can be selected as follows; multi-slice display, continuative multi-window display, separate multi-window display, and multi-window level display. Electronic zooming for the real size viewing can give magnified CT image with one of displayed images if necessary. Image substraction, edge enhancement, smoothing, non-linear gray scale display, and synthesized image for the plane tomography reconstracted by the normal CT scan data, have been tried by the off-line data processing. A possibility for an effective application of the data base with CT image was obtained by these trials. (auth.)

  9. Higher Plasma Myostatin Levels in Cor Pulmonale Secondary to Chronic Obstructive Pulmonary Disease.

    Science.gov (United States)

    Ju, Chun-Rong; Chen, Miao; Zhang, Jian-Heng; Lin, Zhi-Ya; Chen, Rong-Chang

    2016-01-01

    To analyze plasma myostatin levels and investigate their relationship with right ventricular (RV) function in patients with cor pulmonale secondary to chronic obstructive pulmonary disease (COPD). The study recruited 81 patients with advanced COPD and 40 age-matched controls. The patients were divided into two groups: those with cor pulmonale and those without. Echocardiography was used to evaluate RV function and morphology, and the value of tricuspid annular plane systolic excursion (TAPSE) less than 16 mm was considered RV dysfunction. Plasma myostatin levels were analyzed by enzyme-linked immunosorbent assay, and B-type natriuretic peptide (BNP) levels were analyzed as a comparison of myostatin. The data detected cor pulmonale in 39/81 patients, with the mean value of TAPSE of 14.3 mm. Plasma myostatin levels (ng/mL) were significantly higher in patients with cor pulmonale (16.68 ± 2.95) than in those without (13.56 ± 3.09), and much higher than in controls (8.79±2.79), with each pmyostatin levels were significantly correlated with the values of TAPSE and RV myocardium performance index among the COPD patients, and that BNP levels were significantly correlated only with systolic pulmonary arterial pressure, with each pmyostatin levels are increased in COPD patients who have cor pulmonale. Stronger correlations of plasma myostatin levels with echocardiographic indexes of the right heart suggest that myostatin might be superior to BNP in the early diagnosis of cor pulmonale in COPD.

  10. β-endorphins Plasma Level is Higher in Lean Polycystic Ovary Syndrome (PCOS) Women.

    Science.gov (United States)

    Kiałka, M; Milewicz, T; Spałkowska, M; Krzyczkowska-Sendrakowska, M; Wasyl, B; Pełka, A; Krzysiek, J

    2016-01-01

    The evaluation the β-endorphin plasma levels in lean women with polycystic ovary syndrome as well as in women without this disorder. The associations between β-endorphins and other laboratory parameters were also investigated. 31 women lean, defined as women with normal range body mass index, 15 with polycystic ovary syndrome and 16 without this disorder were included to the study. In all the patients the level of β-endorphins was measured. Also the diagnostic laboratory profile including hormone assessment was made in all patients. There were significant differences in β-endorphin levels between the 2 groups. The β-endorphin level was higher in the polycystic ovary syndrome group compared to the healthy controls (15.5±4.37 pg/ml vs. 6.9±2.47 pg/ml, ppolycystic ovary syndrome group. Increase in β-endorphin level of 1 pg/ml was associated with an increase of cortisol at 8 am level of 1.134 µg/dl and decrease of sex hormone binding globuline of 0.948 nmol/l in polycystic ovary syndrome group. Our study showed that the levels of β-endorphins were significantly higher in lean patients with polycystic ovary syndrome than in lean controls. Moreover, β-endorphins levels were found to be correlated with other hormonal parameters. In this respect, β-endorphins may play a role in polycystic ovary syndrome pathophysiology. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Change of direction ability test differentiates higher level and lower level soccer referees

    Science.gov (United States)

    Los, Arcos A; Grande, I; Casajús, JA

    2016-01-01

    This report examines the agility and level of acceleration capacity of Spanish soccer referees and investigates the possible differences between field referees of different categories. The speed test consisted of 3 maximum acceleration stretches of 15 metres. The change of direction ability (CODA) test used in this study was a modification of the Modified Agility Test (MAT). The study included a sample of 41 Spanish soccer field referees from the Navarre Committee of Soccer Referees divided into two groups: i) the higher level group (G1, n = 20): 2ndA, 2ndB and 3rd division referees from the Spanish National Soccer League (28.43 ± 1.39 years); and ii) the lower level group (G2, n = 21): Navarre Provincial League soccer referees (29.54 ± 1.87 years). Significant differences were found with respect to the CODA between G1 (5.72 ± 0.13 s) and G2 (6.06 ± 0.30 s), while no differences were encountered between groups in acceleration ability. No significant correlations were obtained in G1 between agility and the capacity to accelerate. Significant correlations were found between sprint and agility times in the G2 and in the total group. The results of this study showed that agility can be used as a discriminating factor for differentiating between national and regional field referees; however, no observable differences were found over the 5 and 15 m sprint tests. PMID:27274111

  12. Solar active region display system

    Science.gov (United States)

    Golightly, M.; Raben, V.; Weyland, M.

    2003-04-01

    The Solar Active Region Display System (SARDS) is a client-server application that automatically collects a wide range of solar data and displays it in a format easy for users to assimilate and interpret. Users can rapidly identify active regions of interest or concern from color-coded indicators that visually summarize each region's size, magnetic configuration, recent growth history, and recent flare and CME production. The active region information can be overlaid onto solar maps, multiple solar images, and solar difference images in orthographic, Mercator or cylindrical equidistant projections. Near real-time graphs display the GOES soft and hard x-ray flux, flare events, and daily F10.7 value as a function of time; color-coded indicators show current trends in soft x-ray flux, flare temperature, daily F10.7 flux, and x-ray flare occurrence. Through a separate window up to 4 real-time or static graphs can simultaneously display values of KP, AP, daily F10.7 flux, GOES soft and hard x-ray flux, GOES >10 and >100 MeV proton flux, and Thule neutron monitor count rate. Climatologic displays use color-valued cells to show F10.7 and AP values as a function of Carrington/Bartel's rotation sequences - this format allows users to detect recurrent patterns in solar and geomagnetic activity as well as variations in activity levels over multiple solar cycles. Users can customize many of the display and graph features; all displays can be printed or copied to the system's clipboard for "pasting" into other applications. The system obtains and stores space weather data and images from sources such as the NOAA Space Environment Center, NOAA National Geophysical Data Center, the joint ESA/NASA SOHO spacecraft, and the Kitt Peak National Solar Observatory, and can be extended to include other data series and image sources. Data and images retrieved from the system's database are converted to XML and transported from a central server using HTTP and SOAP protocols, allowing

  13. Effect of display type and room illuminance in chest radiographs

    International Nuclear Information System (INIS)

    Liukkonen, Esa; Jartti, Airi; Haapea, Marianne; Oikarinen, Heljae; Ahvenjaervi, Lauri; Mattila, Seija; Nevala, Terhi; Palosaari, Kari; Perhomaa, Marja; Nieminen, Miika T.

    2016-01-01

    To compare diagnostic accuracy in the detection of subtle chest lesions on digital chest radiographs using medical-grade displays, consumer-grade displays, and tablet devices under bright and dim ambient light. Five experienced radiologists independently assessed 50 chest radiographs (32 with subtle pulmonary findings and 18 without apparent findings) under bright (510 lx) and dim (16 lx) ambient lighting. Computed tomography was used as the reference standard for interstitial and nodular lesions and follow-up chest radiograph for pneumothorax. Diagnostic accuracy and sensitivity were calculated for assessments carried out in all displays and compared using the McNemar test. The level of significance was set to p < 0.05. Significant differences in sensitivity between the assessments under bright and dim lighting were found among consumer-grade displays in interstitial opacities with, and in pneumothorax without, Digital Imaging and Communication in Medicine-Grayscale Standard Display Function (DICOM-GSDF) calibration. Compared to 6 megapixel (MP) display under bright lighting, sensitivity in pneumothorax was lower in the tablet device and the consumer-grade display. Sensitivity in interstitial opacities was lower in the DICOM-GSDF calibrated consumer-grade display. A consumer-grade display with or without DICOM-GSDF calibration or a tablet device is not suitable for reading digital chest radiographs in bright lighting. No significant differences were observed between five displays in dim light. (orig.)

  14. Looking forward : In-vehicle auxiliary display positioning affects carsickness

    NARCIS (Netherlands)

    Kuiper, O.X.; Bos, J.E.; Diels, C.

    2018-01-01

    Carsickness is associated with a mismatch between actual and anticipated sensory signals. Occupants of automated vehicles, especially when using a display, are at higher risk of becoming carsick than drivers of conventional vehicles. This study aimed to evaluate the impact of positioning of

  15. Does peer learning or higher levels of e-learning improve learning abilities?

    DEFF Research Database (Denmark)

    Worm, Bjarne Skjødt; Jensen, Kenneth

    2013-01-01

    The fast development of e-learning and social forums demands us to update our understanding of e-learning and peer learning. We aimed to investigate if higher, pre-defined levels of e-learning or social interaction in web forums improved students' learning ability....

  16. Real-time Holographic Display Based on a Super Fast Response Thin Film

    International Nuclear Information System (INIS)

    Gao, Hongyue; Li, Xiao; He, Zhenghong; Su, Yikai; Poon, Ting-Chung

    2013-01-01

    Real-time dynamic holographic display is obtained with super fast response in a thin film without any applied electric field. Holograms can be refreshed in the order of a millisecond and there is no cross talk between the recorded holograms because the hologram formed in the film is transient and can be completely self erased, and the hologram formation time and self-erasure time are both ∼1 ms. Holographic video display is achieved, which shows the real-time holographic image display capability of the thin film, and its much higher resolution than those of commercially available spatial light modulators. Furthermore, multiplexed hologram display using two polarization directions of a recorded light and multiple color holographic display at different laser wavelengths are presented, which demonstrate the feasibility of a RGB color holographic three-dimensional display with the thin film. Because the sample is easy to be fabricated into a large size screen and needs no external applied electric field, we think that the film can be developed into a large-size, dynamic, and color holographic three-dimensional display in the future.

  17. Latest development of display technologies

    International Nuclear Information System (INIS)

    Gao Hong-Yue; Yao Qiu-Xiang; Liu Pan; Zheng Zhi-Qiang; Liu Ji-Cheng; Zheng Hua-Dong; Zeng Chao; Yu Ying-Jie; Sun Tao; Zeng Zhen-Xiang

    2016-01-01

    In this review we will focus on recent progress in the field of two-dimensional (2D) and three-dimensional (3D) display technologies. We present the current display materials and their applications, including organic light-emitting diodes (OLEDs), flexible OLEDs quantum dot light emitting diodes (QLEDs), active-matrix organic light emitting diodes (AMOLEDs), electronic paper (E-paper), curved displays, stereoscopic 3D displays, volumetric 3D displays, light field 3D displays, and holographic 3D displays. Conventional 2D display devices, such as liquid crystal devices (LCDs) often result in ambiguity in high-dimensional data images because of lacking true depth information. This review thus provides a detailed description of 3D display technologies. (topical review)

  18. Liquid crystals beyond displays chemistry, physics, and applications

    CERN Document Server

    Li, Quan

    2012-01-01

    The chemistry, physics, and applications of liquid crystals beyond LCDs Liquid Crystals (LCs) combine order and mobility on a molecular and supramolecular level. But while these remarkable states of matter are most commonly associated with visual display technologies, they have important applications for a variety of other fields as well. Liquid Crystals Beyond Displays: Chemistry, Physics, and Applications considers these, bringing together cutting-edge research from some of the most promising areas of LC science. Featuring contributions from respected researchers from around the globe, th

  19. A wide range gamma monitor with digital display for remote monitoring

    International Nuclear Information System (INIS)

    Risbud, V.H.; Thiagarajan, A.; Gangadharan, P.

    1976-01-01

    A wide range gamma monitor designed for remote monitoring in nuclear facilities is described. The instrument consists of two GM detectors and pre-amplifiers connected by a long coaxial cable to the power supply, scalers and timers and display devices. Automatic selection of detectors range of exposure rate and display (nixie) are achieved with this set up, radiation levels in active areas can easily be displayed in the control room. Other advantages are also pointed out. (A.K.)

  20. Displays and simulators

    Science.gov (United States)

    Mohon, N.

    A 'simulator' is defined as a machine which imitates the behavior of a real system in a very precise manner. The major components of a simulator and their interaction are outlined in brief form, taking into account the major components of an aircraft flight simulator. Particular attention is given to the visual display portion of the simulator, the basic components of the display, their interactions, and their characteristics. Real image displays are considered along with virtual image displays, and image generators. Attention is given to an advanced simulator for pilot training, a holographic pancake window, a scan laser image generator, the construction of an infrared target simulator, and the Apollo Command Module Simulator.

  1. The antioxidant level of Alaska's wild berries: high, higher and highest

    Directory of Open Access Journals (Sweden)

    Roxie Rodgers Dinstel

    2013-08-01

    Full Text Available Background . In the last few years, antioxidants have become the stars of the nutritional world. Antioxidants are important in terms of their ability to protect against oxidative cell damage that can lead to conditions, such as Alzheimer's disease, cancer and heart disease – conditions also linked with chronic inflammation. The antioxidant and anti-inflammatory effects of Alaska's wild berries may have the potential to help prevent these diseases. Objective . To discover the antioxidant levels of Alaska wild berries and the ways these antioxidant levels translate when preservation methods are applied to the berry. Design . This research centred on both the raw berries and products made from the berries. In the first year, a variety of wild berries were tested to discover their oxygen radical absorption capacity (ORAC in the raw berries. The second level of the research project processed 4 different berries – blueberries, lingonberries, salmonberries, highbush cranberries – into 8 or 9 products made from these berries. The products were tested for both ORAC as well as specific antioxidants. Results . The Alaska wild berries collected and tested in the first experiment ranged from 3 to 5 times higher in ORAC value than cultivated berries from the lower 48 states. For instance, cultivated blueberries have an ORAC scale of 30. Alaska wild dwarf blueberries measure 85. This is also higher than lower 48 wild blueberries, which had a score of 61. All of the Alaskan berries tested have a level of antioxidant considered nutritionally valuable, ranging from 19 for watermelon berries to 206 for lingonberries on the ORAC scale. With the processed products made from 4 Alaska wild berries, one of the unexpected outcomes of the research was that the berries continued to have levels of antioxidants considered high, despite the effects of commonly used heat-processing techniques. When berries were dehydrated, per gram ORAC values increased. Conclusion

  2. Ultra-realistic imaging: a new beginning for display holography

    Science.gov (United States)

    Bjelkhagen, Hans I.; Brotherton-Ratcliffe, David

    2014-02-01

    Recent improvements in key foundation technologies are set to potentially transform the field of Display Holography. In particular new recording systems, based on recent DPSS and semiconductor lasers combined with novel recording materials and processing, have now demonstrated full-color analogue holograms of both lower noise and higher spectral accuracy. Progress in illumination technology is leading to a further major reduction in display noise and to a significant increase of the clear image depth and brightness of such holograms. So too, recent progress in 1-step Direct-Write Digital Holography (DWDH) now opens the way to the creation of High Virtual Volume Displays (HVV) - large format full-parallax DWDH reflection holograms having fundamentally larger clear image depths. In a certain fashion HVV displays can be thought of as providing a high quality full-color digital equivalent to the large-format laser-illuminated transmission holograms of the sixties and seventies. Back then, the advent of such holograms led to much optimism for display holography in the market. However, problems with laser illumination, their monochromatic analogue nature and image noise are well cited as being responsible for their failure in reality. Is there reason for believing that the latest technology improvements will make the mark this time around? This paper argues that indeed there is.

  3. Displays enabling mobile multimedia

    Science.gov (United States)

    Kimmel, Jyrki

    2007-02-01

    With the rapid advances in telecommunications networks, mobile multimedia delivery to handsets is now a reality. While a truly immersive multimedia experience is still far ahead in the mobile world, significant advances have been made in the constituent audio-visual technologies to make this become possible. One of the critical components in multimedia delivery is the mobile handset display. While such alternatives as headset-style near-to-eye displays, autostereoscopic displays, mini-projectors, and roll-out flexible displays can deliver either a larger virtual screen size than the pocketable dimensions of the mobile device can offer, or an added degree of immersion by adding the illusion of the third dimension in the viewing experience, there are still challenges in the full deployment of such displays in real-life mobile communication terminals. Meanwhile, direct-view display technologies have developed steadily, and can provide a development platform for an even better viewing experience for multimedia in the near future. The paper presents an overview of the mobile display technology space with an emphasis on the advances and potential in developing direct-view displays further to meet the goal of enabling multimedia in the mobile domain.

  4. On Integrity of Flexible Displays

    Science.gov (United States)

    Bouten, Piet C. P.

    Nowadays two display types are dominant in the display market: the bulky cathode ray tube (CRT) and liquid crystal displays (LCD). Both types use glass as substrate material. The LCD display is the dominant player for mobile applications, in for instance mobile phones and portable computers. In the development of displays and their applications a clear interest exists to replace the rigid rectangular display cells by free-shaped, curved or even roll-up cells. These types of applications require flexible displays.

  5. Modeling the Quality of Videos Displayed With Local Dimming Backlight at Different Peak White and Ambient Light Levels

    DEFF Research Database (Denmark)

    Mantel, Claire; Søgaard, Jacob; Bech, Søren

    2016-01-01

    is computed using a model of the display. Widely used objective quality metrics are applied based on the rendering models of the videos to predict the subjective evaluations. As these predictions are not satisfying, three machine learning methods are applied: partial least square regression, elastic net......This paper investigates the impact of ambient light and peak white (maximum brightness of a display) on the perceived quality of videos displayed using local backlight dimming. Two subjective tests providing quality evaluations are presented and analyzed. The analyses of variance show significant...

  6. Multisensory Stimulation to Improve Low- and Higher-Level Sensory Deficits after Stroke: A Systematic Review.

    Science.gov (United States)

    Tinga, Angelica Maria; Visser-Meily, Johanna Maria Augusta; van der Smagt, Maarten Jeroen; Van der Stigchel, Stefan; van Ee, Raymond; Nijboer, Tanja Cornelia Wilhelmina

    2016-03-01

    The aim of this systematic review was to integrate and assess evidence for the effectiveness of multisensory stimulation (i.e., stimulating at least two of the following sensory systems: visual, auditory, and somatosensory) as a possible rehabilitation method after stroke. Evidence was considered with a focus on low-level, perceptual (visual, auditory and somatosensory deficits), as well as higher-level, cognitive, sensory deficits. We referred to the electronic databases Scopus and PubMed to search for articles that were published before May 2015. Studies were included which evaluated the effects of multisensory stimulation on patients with low- or higher-level sensory deficits caused by stroke. Twenty-one studies were included in this review and the quality of these studies was assessed (based on eight elements: randomization, inclusion of control patient group, blinding of participants, blinding of researchers, follow-up, group size, reporting effect sizes, and reporting time post-stroke). Twenty of the twenty-one included studies demonstrate beneficial effects on low- and/or higher-level sensory deficits after stroke. Notwithstanding these beneficial effects, the quality of the studies is insufficient for valid conclusion that multisensory stimulation can be successfully applied as an effective intervention. A valuable and necessary next step would be to set up well-designed randomized controlled trials to examine the effectiveness of multisensory stimulation as an intervention for low- and/or higher-level sensory deficits after stroke. Finally, we consider the potential mechanisms of multisensory stimulation for rehabilitation to guide this future research.

  7. Wellbeing in the Welfare State: level not higher, distribution not more equitable

    NARCIS (Netherlands)

    R. Veenhoven (Ruut)

    2000-01-01

    textabstract'Wellbeing' and 'welfare' are often bracketed together, in particular wellbeing and state-welfare. The level of wellbeing is believed to be higher in welfare states, and its distribution more equitable. This theory is tested in a comparative study of 40 nations 1980-1990. The size of

  8. Book Display as Adult Service

    Directory of Open Access Journals (Sweden)

    Matthew S. Moore

    1997-03-01

    Full Text Available 無Book display as an adult service is defined as choosing and positioning adult books from the collection to increase their circulation. The author contrasts bookstore arrangement for sales versus library arrangement for access. The paper considers the library-as-a-whole as a display, examines the right size for an in-library display, and discusses mass displays, end-caps, on-shelf displays, and the Tiffany approach. The author proposes that an effective display depends on an imaginative, unifying theme, and that book displays are part of the joy of libraries.

  9. The effect of base image window level selection on the dimensional measurement accuracy of resultant three-dimensional image displays

    International Nuclear Information System (INIS)

    Kurmis, A.P.; Hearn, T.C.; Reynolds, K.J.

    2003-01-01

    Purpose: The aim of this study was to determine the effect of base image window level selection on direct linear measurement of knee structures displayed using new magnetic resonance (MR)-based three-dimensional reconstructed computer imaging techniques. Methods: A prospective comparative study was performed using a series of three-dimensional knee images, generated from conventional MR imaging (MRI) sections. Thirty distinct anatomical structural features were identified within the image series of which repeated measurements were compared at 10 different window grey scale levels. Results: Statistical analysis demonstrated an excellent raw correlation between measurements and suggested no significant difference between measurements made at each of the 10 window level settings (P>0.05). Conclusions: The findings of this study suggest that unlike conventional MR or CT applications, grey scale window level selection at the time of imaging does not significantly affect the visual quality of resultant three-dimensional reconstructed images and hence the accuracy of subsequent direct linear measurement. The diagnostic potential of clinical progression from routine two-dimensional to advanced three-dimensional reconstructed imaging techniques may therefore be less likely to be degraded by inappropriate MR technician image windowing during the capturing of image series

  10. Higher Plasma Myostatin Levels in Cor Pulmonale Secondary to Chronic Obstructive Pulmonary Disease.

    Directory of Open Access Journals (Sweden)

    Chun-Rong Ju

    Full Text Available To analyze plasma myostatin levels and investigate their relationship with right ventricular (RV function in patients with cor pulmonale secondary to chronic obstructive pulmonary disease (COPD.The study recruited 81 patients with advanced COPD and 40 age-matched controls. The patients were divided into two groups: those with cor pulmonale and those without. Echocardiography was used to evaluate RV function and morphology, and the value of tricuspid annular plane systolic excursion (TAPSE less than 16 mm was considered RV dysfunction. Plasma myostatin levels were analyzed by enzyme-linked immunosorbent assay, and B-type natriuretic peptide (BNP levels were analyzed as a comparison of myostatin.The data detected cor pulmonale in 39/81 patients, with the mean value of TAPSE of 14.3 mm. Plasma myostatin levels (ng/mL were significantly higher in patients with cor pulmonale (16.68 ± 2.95 than in those without (13.56 ± 3.09, and much higher than in controls (8.79±2.79, with each p<0.01. Significant differences were also found in plasma BNP levels among the three groups (p<0.05. Multivariate regression analysis suggested that myostatin levels were significantly correlated with the values of TAPSE and RV myocardium performance index among the COPD patients, and that BNP levels were significantly correlated only with systolic pulmonary arterial pressure, with each p<0.05.Plasma myostatin levels are increased in COPD patients who have cor pulmonale. Stronger correlations of plasma myostatin levels with echocardiographic indexes of the right heart suggest that myostatin might be superior to BNP in the early diagnosis of cor pulmonale in COPD.

  11. High performance visual display for HENP detectors

    CERN Document Server

    McGuigan, M; Spiletic, J; Fine, V; Nevski, P

    2001-01-01

    A high end visual display for High Energy Nuclear Physics (HENP) detectors is necessary because of the sheer size and complexity of the detector. For BNL this display will be of special interest because of STAR and ATLAS. To load, rotate, query, and debug simulation code with a modern detector simply takes too long even on a powerful work station. To visualize the HENP detectors with maximal performance we have developed software with the following characteristics. We develop a visual display of HENP detectors on BNL multiprocessor visualization server at multiple level of detail. We work with general and generic detector framework consistent with ROOT, GAUDI etc, to avoid conflicting with the many graphic development groups associated with specific detectors like STAR and ATLAS. We develop advanced OpenGL features such as transparency and polarized stereoscopy. We enable collaborative viewing of detector and events by directly running the analysis in BNL stereoscopic theatre. We construct enhanced interactiv...

  12. Higher Dialysate Matrix Metalloproteinase-2 Levels Are Associated with Peritoneal Membrane Dysfunction

    Science.gov (United States)

    Cho, Yeoungjee; Johnson, David W.; Vesey, David A.; Hawley, Carmel M.; Pascoe, Elaine M.; Clarke, Margaret; Topley, Nicholas

    2016-01-01

    ♦ Background: Peritoneal dialysis (PD) patients develop progressive and cumulative peritoneal injury with longer time spent on PD. The present study aimed to a) describe the trend of peritoneal injury biomarkers, matrix metalloproteinase-2 (MMP-2) and tissue inhibitor of metalloproteinase-1 (TIMP-1), in incident PD patients, b) to explore the capacity of dialysate MMP-2 to predict peritoneal solute transport rate (PSTR) and peritonitis, and c) to evaluate the influence of neutral pH, low glucose degradation product (GDP) PD solution on these outcomes. ♦ Methods: The study included 178 participants from the balANZ trial who had at least 1 stored dialysate sample. Changes in PSTR and peritonitis were primary outcome measures, and the utility of MMP-2 in predicting these outcomes was analyzed using multilevel linear regression and multilevel Poisson regression, respectively. ♦ Results: Significant linear increases in dialysate MMP-2 and TIMP-1 concentrations were observed (p < 0.001), but neither was affected by the type of PD solutions received (MMP-2: p = 0.07; TIMP-1: p = 0.63). An increase in PSTR from baseline was associated with higher levels of MMP-2 (p = 0.02), and the use of standard solutions over longer PD duration (p = 0.001). The risk of peritonitis was independently predicted by higher dialysate MMP-2 levels (incidence rate ratio [IRR] per ng/mL 1.01, 95% confidence interval [CI] 1.005 – 1.02, p = 0.002) and use of standard solutions (Biocompatible solution: IRR 0.45, 95% CI 0.24 – 0.85, p = 0.01). ♦ Conclusion: Dialysate MMP-2 and TIMP-1 concentrations increased with longer PD duration. Higher MMP-2 levels were associated with faster PSTR and future peritonitis risk. Administration of biocompatible solutions exerted no significant effect on dialysate levels of MMP-2 or TIMP-1, but did counteract the increase in PSTR and the risk of peritonitis associated with the use of standard PD solutions. This is the first longitudinal study to examine

  13. Augmenting digital displays with computation

    Science.gov (United States)

    Liu, Jing

    As we inevitably step deeper and deeper into a world connected via the Internet, more and more information will be exchanged digitally. Displays are the interface between digital information and each individual. Naturally, one fundamental goal of displays is to reproduce information as realistically as possible since humans still care a lot about what happens in the real world. Human eyes are the receiving end of such information exchange; therefore it is impossible to study displays without studying the human visual system. In fact, the design of displays is rather closely coupled with what human eyes are capable of perceiving. For example, we are less interested in building displays that emit light in the invisible spectrum. This dissertation explores how we can augment displays with computation, which takes both display hardware and the human visual system into consideration. Four novel projects on display technologies are included in this dissertation: First, we propose a software-based approach to driving multiview autostereoscopic displays. Our display algorithm can dynamically assign views to hardware display zones based on multiple observers' current head positions, substantially reducing crosstalk and stereo inversion. Second, we present a dense projector array that creates a seamless 3D viewing experience for multiple viewers. We smoothly interpolate the set of viewer heights and distances on a per-vertex basis across the arrays field of view, reducing image distortion, crosstalk, and artifacts from tracking errors. Third, we propose a method for high dynamic range display calibration that takes into account the variation of the chrominance error over luminance. We propose a data structure for enabling efficient representation and querying of the calibration function, which also allows user-guided balancing between memory consumption and the amount of computation. Fourth, we present user studies that demonstrate that the ˜ 60 Hz critical flicker fusion

  14. Color display and encryption with a plasmonic polarizing metamirror

    Directory of Open Access Journals (Sweden)

    Song Maowen

    2018-01-01

    Full Text Available Structural colors emerge when a particular wavelength range is filtered out from a broadband light source. It is regarded as a valuable platform for color display and digital imaging due to the benefits of environmental friendliness, higher visibility, and durability. However, current devices capable of generating colors are all based on direct transmission or reflection. Material loss, thick configuration, and the lack of tunability hinder their transition to practical applications. In this paper, a novel mechanism that generates high-purity colors by photon spin restoration on ultrashallow plasmonic grating is proposed. We fabricated the sample by interference lithography and experimentally observed full color display, tunable color logo imaging, and chromatic sensing. The unique combination of high efficiency, high-purity colors, tunable chromatic display, ultrathin structure, and friendliness for fabrication makes this design an easy way to bridge the gap between theoretical investigations and daily-life applications.

  15. Higher Levels of Albuminuria within the Normal Range Predict Incident Hypertension

    OpenAIRE

    Forman, John P.; Fisher, Naomi D.L.; Schopick, Emily L.; Curhan, Gary C.

    2008-01-01

    Higher levels of albumin excretion within the normal range are associated with cardiovascular disease in high-risk individuals. Whether incremental increases in urinary albumin excretion, even within the normal range, are associated with the development of hypertension in low-risk individuals is unknown. This study included 1065 postmenopausal women from the first Nurses’ Health Study and 1114 premenopausal women from the second Nurses’ Health Study who had an albumin/creatinine ratio

  16. Display of adenoregulin with a novel Pichia pastoris cell surface display system.

    Science.gov (United States)

    Ren, Ren; Jiang, Zhengbing; Liu, Meiyun; Tao, Xinyi; Ma, Yushu; Wei, Dongzhi

    2007-02-01

    Two Pichia pastoris cell surface display vectors were constructed. The vectors consisted of the flocculation functional domain of Flo1p with its own secretion signal sequence or the alpha-factor secretion signal sequence, a polyhistidine (6xHis) tag for detection, an enterokinase recognition site, and the insertion sites for target proteins. Adenoregulin (ADR) is a 33-amino-acid antimicrobial peptide isolated from Phyllomedusa bicolor skin. The ADR was expressed and displayed on the Pichia pastoris KM71 cell surface with the system reported. The displayed recombinant ADR fusion protein was detected by fluorescence microscopy and confocal laser scanning microscopy (CLSM). The antimicrobial activity of the recombinant adenoregulin was detected after proteolytic cleavage of the fusion protein on cell surface. The validity of the Pichia pastoris cell surface display vectors was proved by the displayed ADR.

  17. Spacesuit Data Display and Management System

    Science.gov (United States)

    Hall, David G.; Sells, Aaron; Shah, Hemal

    2009-01-01

    A prototype embedded avionics system has been designed for the next generation of NASA extra-vehicular-activity (EVA) spacesuits. The system performs biomedical and other sensor monitoring, image capture, data display, and data transmission. An existing NASA Phase I and II award winning design for an embedded computing system (ZIN vMetrics - BioWATCH) has been modified. The unit has a reliable, compact form factor with flexible packaging options. These innovations are significant, because current state-of-the-art EVA spacesuits do not provide capability for data displays or embedded data acquisition and management. The Phase 1 effort achieved Technology Readiness Level 4 (high fidelity breadboard demonstration). The breadboard uses a commercial-grade field-programmable gate array (FPGA) with embedded processor core that can be upgraded to a space-rated device for future revisions.

  18. Controlling Power Consumption for Displays With Backlight Dimming

    DEFF Research Database (Denmark)

    Mantel, Claire; Burini, Nino; Nadernejad, Ehsan

    2013-01-01

    Backlight dimming of Liquid Crystal Displays (LCD) is a technology which aims at saving power and improving visual quality. The evolution of energy standards and the increasing public expectations regarding power consumption have made it necessary for backlight systems to manage their power....... Such a control is challenging to implement, because for LCD displays quality and power are closely interlinked, and one cannot be modified without affecting the other. To address this issue, we present a framework for power controlled backlight dimming defining some key concepts. Two methods to obtain backlights...... with a predefined power level for images are presented: one method has low complexity and the other achieves high performance in terms of quality/power trade-off. Those methods are evaluated on a modeled Light-Emitting Diode edge-lit backlight display. The high-performance method performs significantly better than...

  19. Control/display trade-off study for single-pilot instrument flight rule operations

    Science.gov (United States)

    Hoh, R.

    1983-01-01

    The objectives were to determine minimum autopilot functions and displays required to keep pilot workload at an acceptable level; to determine what constitutes an acceptable level of workload; to identify critical tasks; and to suggest specific experiments required to refine conclusions. It was determined that workload relief is derived from basic stability augmentation; that complex autopilots can lead to serious blunders; and that displays need to enhance positional awareness and minimize the likelihood of false hypothesis.

  20. Flat panel display - Impurity doping technology for flat panel displays

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Toshiharu [Advanced Technology Planning, Sumitomo Eaton Nova Corporation, SBS Tower 9F, 10-1, Yoga 4-chome, Setagaya-ku, 158-0097 Tokyo (Japan)]. E-mail: suzuki_tsh@senova.co.jp

    2005-08-01

    Features of the flat panel displays (FPDs) such as liquid crystal display (LCD) and organic light emitting diode (OLED) display, etc. using low temperature poly-Si (LTPS) thin film transistors (TFTs) are briefly reviewed comparing with other FPDs. The requirements for fabricating TFTs used for high performance FPDs and system on glass (SoG) are addressed. This paper focuses on the impurity doping technology, which is one of the key technologies together with crystallization by laser annealing, formation of high quality gate insulator and gate-insulator/poly-Si interface. The issues to be solved in impurity doping technology for state of the art and future TFTs are clarified.

  1. Flat panel display - Impurity doping technology for flat panel displays

    International Nuclear Information System (INIS)

    Suzuki, Toshiharu

    2005-01-01

    Features of the flat panel displays (FPDs) such as liquid crystal display (LCD) and organic light emitting diode (OLED) display, etc. using low temperature poly-Si (LTPS) thin film transistors (TFTs) are briefly reviewed comparing with other FPDs. The requirements for fabricating TFTs used for high performance FPDs and system on glass (SoG) are addressed. This paper focuses on the impurity doping technology, which is one of the key technologies together with crystallization by laser annealing, formation of high quality gate insulator and gate-insulator/poly-Si interface. The issues to be solved in impurity doping technology for state of the art and future TFTs are clarified

  2. Handbook of Visual Display Technology

    CERN Document Server

    Cranton, Wayne; Fihn, Mark

    2012-01-01

    The Handbook of Visual Display Technology is a unique work offering a comprehensive description of the science, technology, economic and human interface factors associated with the displays industry. An invaluable compilation of information, the Handbook will serve as a single reference source with expert contributions from over 150 international display professionals and academic researchers. All classes of display device are covered including LCDs, reflective displays, flexible solutions and emissive devices such as OLEDs and plasma displays, with discussion of established principles, emergent technologies, and particular areas of application. The wide-ranging content also encompasses the fundamental science of light and vision, image manipulation, core materials and processing techniques, display driving and metrology.

  3. Polymer Dispersed Liquid Crystal Displays

    Science.gov (United States)

    Doane, J. William

    The following sections are included: * INTRODUCTION AND HISTORICAL DEVELOPMENT * PDLC MATERIALS PREPARATION * Polymerization induced phase separation (PIPS) * Thermally induced phase separation (TIPS) * Solvent induced phase separation (SIPS) * Encapsulation (NCAP) * RESPONSE VOLTAGE * Dielectric and resistive effects * Radial configuration * Bipolar configuration * Other director configurations * RESPONSE TIME * DISPLAY CONTRAST * Light scattering and index matching * Incorporation of dyes * Contrast measurements * PDLC DISPLAY DEVICES AND INNOVATIONS * Reflective direct view displays * Large-scale, flexible displays * Switchable windows * Projection displays * High definition spatial light modulator * Haze-free PDLC shutters: wide angle view displays * ENVIRONMENTAL STABILITY * ACKNOWLEDGEMENTS * REFERENCES

  4. Information rich display design

    International Nuclear Information System (INIS)

    Welch, Robin; Braseth, Alf Ove; Veland, Oeystein

    2004-01-01

    This paper presents the concept Information Rich Displays. The purpose of Information Rich Displays (IRDs) is to condensate prevailing information in process displays in such a way that each display format (picture) contains more relevant information for the user. Compared to traditional process control displays, this new concept allows the operator to attain key information at a glance and at the same time allows for improved monitoring of larger portions of the process. This again allows for reduced navigation between both process and trend displays and ease the cognitive demand on the operator. This concept has been created while working on designing display prototypes for the offshore petroleum production facilities of tomorrow. Offshore installations basically consist of wells, separation trains (where oil, gas and water are separated from each other), an oil tax measurement system (where oil quality is measured and the pressure increased to allow for export), gas compression (compression of gas for export) and utility systems (water treatment, chemical systems etc.). This means that an offshore control room operator has to deal with a complex process that comprises several functionally different systems. The need for a new approach to offshore display format design is in particular based on shortcomings in today's designs related to the keyhole effect, where the display format only reveals a fraction of the whole process. Furthermore, the upcoming introduction of larger off- and on-shore operation centres will increase the size and complexity of the operators' work domain. In the light of the increased demands on the operator, the proposed IRDs aim to counter the negative effects this may have on the workload. In this work we have attempted to classify the wide range of different roles an operator can have in different situations. The information content and amount being presented to the operator in a display should be viewed in context of the roles the

  5. The behavioral context of visual displays in common marmosets (Callithrix jacchus).

    Science.gov (United States)

    de Boer, Raïssa A; Overduin-de Vries, Anne M; Louwerse, Annet L; Sterck, Elisabeth H M

    2013-11-01

    Communication is important in social species, and may occur with the use of visual, olfactory or auditory signals. However, visual communication may be hampered in species that are arboreal have elaborate facial coloring and live in small groups. The common marmoset fits these criteria and may have limited visual communication. Nonetheless, some (contradictive) propositions concerning visual displays in the common marmoset have been made, yet quantitative data are lacking. The aim of this study was to assign a behavioral context to different visual displays using pre-post-event-analyses. Focal observations were conducted on 16 captive adult and sub-adult marmosets in three different family groups. Based on behavioral elements with an unambiguous meaning, four different behavioral contexts were distinguished: aggression, fear, affiliation, and play behavior. Visual displays concerned behavior that included facial expressions, body postures, and pilo-erection of the fur. Visual displays related to aggression, fear, and play/affiliation were consistent with the literature. We propose that the visual display "pilo-erection tip of tail" is related to fear. Individuals receiving these fear signals showed a higher rate of affiliative behavior. This study indicates that several visual displays may provide cues or signals of particular social contexts. Since the three displays of fear elicited an affiliative response, they may communicate a request of anxiety reduction or signal an external referent. Concluding, common marmosets, despite being arboreal and living in small groups, use several visual displays to communicate with conspecifics and their facial coloration may not hamper, but actually promote the visibility of visual displays. © 2013 Wiley Periodicals, Inc.

  6. Color dependence with horizontal-viewing angle and colorimetric characterization of two displays using different backlighting

    Science.gov (United States)

    Castro, José J.; Pozo, Antonio M.; Rubiño, Manuel

    2013-11-01

    In this work we studied the color dependence with a horizontal-viewing angle and colorimetric characterization of two liquid-crystal displays (LCD) using two different backlighting: Cold Cathode Fluorescent Lamps (CCFLs) and light-emitting diodes (LEDs). The LCDs studied had identical resolution, size, and technology (TFT - thin film transistor). The colorimetric measurements were made with the spectroradiometer SpectraScan PR-650 following the procedure recommended in the European guideline EN 61747-6. For each display, we measured at the centre of the screen the chromaticity coordinates at horizontal viewing angles of 0, 20, 40, 60 and 80 degrees for the achromatic (A), red (R), green (G) and blue (B) channels. Results showed a greater color-gamut area for the display with LED backlight, compared with the CCFL backlight, showing a greater range of colors perceptible by human vision. This color-gamut area diminished with viewing angle for both displays. Higher differences between trends for viewing angles were observed in the LED-backlight, especially for the R- and G-channels, demonstrating a higher variability of the chromaticity coordinates with viewing angle. The best additivity was reached by the LED-backlight display (a lower error percentage). LED-backlight display provided better color performance of visualization.

  7. Gender in higher level education and professional training in water supply and sanitation.

    Science.gov (United States)

    Borba, M

    1997-01-01

    While more women are participating in training and decision-making in the local-level drinking water and sanitation sectors, this is not occurring at higher levels because of the gender imbalance that remains in higher-level sector education and professional training programs. This imbalance is characterized by gender-biased science curricula and by a lack of female role models. Even in developing countries where female enrollment outstrips that of men in higher education, women commonly prepare for careers in areas that are less valued than sanitary engineering. This imbalance ignores the fact that women can perform technical and managerial skills as competently as men. A similar male-dominated pattern emerges in professional training courses offered by development agencies, especially courses that focus on management issues. Low female school attendance begins when girls must forego primary school attendance to help their mothers in domestic chores, such as fetching water. Inadequate sanitation facilities for girls at schools also pose impediments. Efforts to improve this situation include 1) a promotional brochure developed by the Botswana Ministry of Education to raise awareness of the importance of men's and women's work as technicians and engineers in the water and sanitation sector among secondary school students; 2) creation of free schools and universities in Oman, where the numbers of women in previously male-dominated jobs are increasing; and 3) promotion of female education at the Asian Institute of Technology.

  8. An interactive display system for large-scale 3D models

    Science.gov (United States)

    Liu, Zijian; Sun, Kun; Tao, Wenbing; Liu, Liman

    2018-04-01

    With the improvement of 3D reconstruction theory and the rapid development of computer hardware technology, the reconstructed 3D models are enlarging in scale and increasing in complexity. Models with tens of thousands of 3D points or triangular meshes are common in practical applications. Due to storage and computing power limitation, it is difficult to achieve real-time display and interaction with large scale 3D models for some common 3D display software, such as MeshLab. In this paper, we propose a display system for large-scale 3D scene models. We construct the LOD (Levels of Detail) model of the reconstructed 3D scene in advance, and then use an out-of-core view-dependent multi-resolution rendering scheme to realize the real-time display of the large-scale 3D model. With the proposed method, our display system is able to render in real time while roaming in the reconstructed scene and 3D camera poses can also be displayed. Furthermore, the memory consumption can be significantly decreased via internal and external memory exchange mechanism, so that it is possible to display a large scale reconstructed scene with over millions of 3D points or triangular meshes in a regular PC with only 4GB RAM.

  9. A study on mobile PC display design in NPP maintenance considering the level of expertise

    International Nuclear Information System (INIS)

    Kim, In

    2010-02-01

    Recently, the importance of effective maintenance in nuclear power plants (NPPs) has been emphasized and research into effective maintenance by adopting mobile maintenance aids (MMAs) have been attempted. MMAs are currently used during operation and maintenance in NPPs, but no method that considers the limitations of mobile devices has been proposed. For improved and effective use, an MMA display design method based on abstraction hierarchy (AH) is proposed and its design considerations are discussed in this study. Six levels of abstraction hierarchy are proposed in this paper to classify the maintenance information. By classifying and organizing maintenance information using AH, maintenance information can be used effectively by users either high or low levels of expertise. When information classification has been finished, the information requirements and relationships for MMA design is extracted from the analysis of the AH result. Representative human-machine interface (HMI) guidelines issued by the US NRC, which are generally used in NPPs, are applied. With the considerations of MMA design analysis and practical guidelines, AH-based MMA is designed for maintenance tasks. An experiment is conducted using the AH-based MMA in order to estimate the effectiveness of the proposed method for maintenance tasks and to identify design considerations to enhance the proposed MMAs. The result indicated that an AH-based manual was more effective than a conventional manual in terms of task completion time and number of errors. The workload for the AH-based manual was estimated to be less than the conventional manual for low levels of expertise. However, a conventional manual was more comprehensive than the proposed manual and the steps contained in the maintenance manual were easier to remember. As the level of expertise increases, subjects tended to follow more abstract information while the number of navigations decreased. It is believed that when mobile devices become

  10. iFlit: an ambient display to induce cognitive dissonance and behaviour change

    Directory of Open Access Journals (Sweden)

    R. Maimone

    2014-03-01

    Full Text Available In this paper, we explore how persuasive ambient displays could induce cognitive dissonance to promote positive behaviour change among graduate students. We developed iFlit –an interactive and collective ambient display that enables a group of students to reflect on their burnout level, and sleeping and activity habits. iFlit shows a garden with birds representing students monitored behaviour. Birds move according to users’ activity level, and the garden’s background changes according to each user’s sleeping habits. Users match peers perceived burnout, and sleep and activity habits to induce cognitive dissonance. We argue such displays are more efficient than personal devices to empower individuals’ self-reflection due their capabilities for enabling a playful interaction with their personal data.

  11. Touch displays: the effects of palm rejection technology on productivity, comfort, biomechanics and positioning.

    Science.gov (United States)

    Camilleri, Matt J; Malige, Ajith; Fujimoto, Jeffrey; Rempel, David M

    2013-01-01

    Direct touch displays can improve the human-computer experience and productivity; however, the higher hand locations may increase shoulder fatigue. Palm rejection (PR) technology may reduce shoulder loads by allowing the palms to rest on the display and increase productivity by registering the touched content and fingertips through the palms rather than shoulders. The effects of PR were evaluated by having participants perform touch tasks while posture and reaction force on the display were measured. Enabling PR, during which the subjects could place the palms on the display (but were not required to), resulted in increased wrist extension, force applied to the display and productivity, and less discomfort, but had no effect on the self-selected positioning of the display. Participants did not deliberately place their palms on the display; therefore, there was no reduction in shoulder load and the increased productivity was not due to improved hand registration. The increased productivity may have been due to reduced interruptions from palm contacts or reduced motor control demands.

  12. Technical trends of large-size photomasks for flat panel displays

    Science.gov (United States)

    Yoshida, Koichiro

    2017-06-01

    Currently, flat panel displays (FPDs) are one of the main parts for information technology devices and sets. From 1990's to 2000's, liquid crystal displays (LCDs) and plasma displays had been mainstream FPDs. In the middle of 2000's, demand of plasma displays declined and organic light emitting diodes (OLEDs) newly came into FPD market. And today, major technology of FPDs are LCDs and OLEDs. Especially for mobile devices, the penetration of OLEDs is remarkable. In FPDs panel production, photolithography is the key technology as same as LSI. Photomasks for FPDs are used not only as original master of circuit pattern, but also as a tool to form other functional structures of FPDs. Photomasks for FPDs are called as "Large Size Photomasks(LSPMs)", since the remarkable feature is " Size" which reaches over 1- meter square and over 100kg. In this report, we discuss three LSPMs technical topics with FPDs technical transition and trend. The first topics is upsizing of LSPMs, the second is the challenge for higher resolution patterning, and the last is "Multi-Tone Mask" for "Half -Tone Exposure".

  13. Higher-level fusion for military operations based on abductive inference: proof of principle

    Science.gov (United States)

    Pantaleev, Aleksandar V.; Josephson, John

    2006-04-01

    The ability of contemporary military commanders to estimate and understand complicated situations already suffers from information overload, and the situation can only grow worse. We describe a prototype application that uses abductive inferencing to fuse information from multiple sensors to evaluate the evidence for higher-level hypotheses that are close to the levels of abstraction needed for decision making (approximately JDL levels 2 and 3). Abductive inference (abduction, inference to the best explanation) is a pattern of reasoning that occurs naturally in diverse settings such as medical diagnosis, criminal investigations, scientific theory formation, and military intelligence analysis. Because abduction is part of common-sense reasoning, implementations of it can produce reasoning traces that are very human understandable. Automated abductive inferencing can be deployed to augment human reasoning, taking advantage of computation to process large amounts of information, and to bypass limits to human attention and short-term memory. We illustrate the workings of the prototype system by describing an example of its use for small-unit military operations in an urban setting. Knowledge was encoded as it might be captured prior to engagement from a standard military decision making process (MDMP) and analysis of commander's priority intelligence requirements (PIR). The system is able to reasonably estimate the evidence for higher-level hypotheses based on information from multiple sensors. Its inference processes can be examined closely to verify correctness. Decision makers can override conclusions at any level and changes will propagate appropriately.

  14. Display technologies for augmented reality

    Science.gov (United States)

    Lee, Byoungho; Lee, Seungjae; Jang, Changwon; Hong, Jong-Young; Li, Gang

    2018-02-01

    With the virtue of rapid progress in optics, sensors, and computer science, we are witnessing that commercial products or prototypes for augmented reality (AR) are penetrating into the consumer markets. AR is spotlighted as expected to provide much more immersive and realistic experience than ordinary displays. However, there are several barriers to be overcome for successful commercialization of AR. Here, we explore challenging and important topics for AR such as image combiners, enhancement of display performance, and focus cue reproduction. Image combiners are essential to integrate virtual images with real-world. Display performance (e.g. field of view and resolution) is important for more immersive experience and focus cue reproduction may mitigate visual fatigue caused by vergence-accommodation conflict. We also demonstrate emerging technologies to overcome these issues: index-matched anisotropic crystal lens (IMACL), retinal projection displays, and 3D display with focus cues. For image combiners, a novel optical element called IMACL provides relatively wide field of view. Retinal projection displays may enhance field of view and resolution of AR displays. Focus cues could be reconstructed via multi-layer displays and holographic displays. Experimental results of our prototypes are explained.

  15. The effect of modifiable healthy practices on higher-level functional capacity decline among Japanese community dwellers

    Directory of Open Access Journals (Sweden)

    Rei Otsuka

    2017-03-01

    Full Text Available This study aimed to clarify the effects of the accumulation of 8 modifiable practices related to health, including smoking, alcohol drinking, physical activity, sleeping hours, body mass index, dietary diversity, ikigai (life worth living, and health checkup status, on higher-level functional capacity decline among Japanese community dwellers. Data were derived from the National Institute for Longevity Sciences - Longitudinal Study of Aging. Subjects comprised 1269 men and women aged 40 to 79 years at baseline (1997–2000 who participated in a follow-up postal survey (2013. Higher-level functional capacity was measured using the Tokyo Metropolitan Institute of Gerontology Index of Competence (total score and 3 subscales: instrumental self-maintenance, intellectual activity, and social role. The odds ratio (OR and 95% confidence interval (CI for a decline in higher-level functional capacity in the follow-up study according to the total number of healthy practices were analyzed using the lowest category as a reference. Multivariate adjusted ORs (95% CIs for the total score of higher-level functional capacity, which declined according to the total number of healthy practices (0–4, 5–6, 7–8 groups were 1.00 (reference, 0.63 (0.44–0.92, and 0.54 (0.31–0.94. For the score of social role decline, multivariate adjusted ORs (95% CIs were 1.00 (reference, 0.62 (0.40–0.97, and 0.46 (0.23–0.90, respectively (P for trend = 0.04. Having more modifiable healthy practices, especially in social roles, may protect against a decline in higher-level functional capacity among middle-aged and elderly community dwellers in Japan.

  16. The effect of modifiable healthy practices on higher-level functional capacity decline among Japanese community dwellers.

    Science.gov (United States)

    Otsuka, Rei; Nishita, Yukiko; Tange, Chikako; Tomida, Makiko; Kato, Yuki; Nakamoto, Mariko; Ando, Fujiko; Shimokata, Hiroshi; Suzuki, Takao

    2017-03-01

    This study aimed to clarify the effects of the accumulation of 8 modifiable practices related to health, including smoking, alcohol drinking, physical activity, sleeping hours, body mass index, dietary diversity, ikigai (life worth living), and health checkup status, on higher-level functional capacity decline among Japanese community dwellers. Data were derived from the National Institute for Longevity Sciences - Longitudinal Study of Aging. Subjects comprised 1269 men and women aged 40 to 79 years at baseline (1997-2000) who participated in a follow-up postal survey (2013). Higher-level functional capacity was measured using the Tokyo Metropolitan Institute of Gerontology Index of Competence (total score and 3 subscales: instrumental self-maintenance, intellectual activity, and social role). The odds ratio (OR) and 95% confidence interval (CI) for a decline in higher-level functional capacity in the follow-up study according to the total number of healthy practices were analyzed using the lowest category as a reference. Multivariate adjusted ORs (95% CIs) for the total score of higher-level functional capacity, which declined according to the total number of healthy practices (0-4, 5-6, 7-8 groups) were 1.00 (reference), 0.63 (0.44-0.92), and 0.54 (0.31-0.94). For the score of social role decline, multivariate adjusted ORs (95% CIs) were 1.00 (reference), 0.62 (0.40-0.97), and 0.46 (0.23-0.90), respectively (P for trend = 0.04). Having more modifiable healthy practices, especially in social roles, may protect against a decline in higher-level functional capacity among middle-aged and elderly community dwellers in Japan.

  17. Next generation smart window display using transparent organic display and light blocking screen.

    Science.gov (United States)

    Kim, Gyeong Woo; Lampande, Raju; Choe, Dong Cheol; Ko, Ik Jang; Park, Jin Hwan; Pode, Ramchandra; Kwon, Jang Hyuk

    2018-04-02

    Transparent organic light emitting diodes (TOLED) have widespread applications in the next-generation display devices particularly in the large size transparent window and interactive displays. Herein, we report high performance and stable attractive smart window displays using facile process. Advanced smart window display is realized by integrating the high performance light blocking screen and highly transparent white OLED panel. The full smart window display reveals a maximum transmittance as high as 64.2% at the wavelength of 600 nm and extremely good along with tunable ambient contrast ratio (171.94:1) compared to that of normal TOLED (4.54:1). Furthermore, the performance decisive light blocking screen has demonstrated an excellent optical and electrical characteristics such as i) high transmittance (85.56% at 562nm) at light-penetrating state, ii) superior absorbance (2.30 at 562nm) in light interrupting mode, iii) high optical contrast (85.50 at 562 nm), iv) high optical stability for more than 25,000 cycle of driving, v) fast switching time of 1.9 sec, and vi) low driving voltage of 1.7 V. The experimental results of smart window display are also validated using optical simulation. The proposed smart window display technology allows us to adjust the intensity of daylight entering the system quickly and conveniently.

  18. Progress on visual display terminal syndrome in children

    Directory of Open Access Journals (Sweden)

    Xiao-Fang Ren

    2013-12-01

    Full Text Available With the rapid development of information era, video display terminal(VDThas entered people's lives, and the operator's health problems have been recognized, which is so called VDT syndrome. At the same time, the frequency of children's exposure to the VDT is higher and higher. Childhood is the critical period of visual development. As the data show that the excessive use of VDT can cause eye fatigue, myopia, dry eye, abnormal blinking, headache and other symptoms. In this article, we will talk about the symptoms, mechanism, and the prevention and treatment of children's VDT syndrome.

  19. Visual merchandising window display

    Directory of Open Access Journals (Sweden)

    Opris (Cas. Stanila M.

    2013-12-01

    Full Text Available Window display plays a major part in the selling strategies; it does not only include the simple display of goods, nowadays it is a form of art, also having the purpose of sustaining the brand image. This article wants to reveal the tools that are essential in creating a fabulous window display. Being a window designer is not an easy job, you have to always think ahead trends, to have a sense of colour, to know how to use light to attract customers in the store after only one glance at the window. The big store window displays are theatre scenes: with expensive backgrounds, special effects and high fashion mannequins. The final role of the displays is to convince customers to enter the store and trigger the purchasing act which is the final goal of the retail activity.

  20. Associations between Depressive State and Impaired Higher-Level Functional Capacity in the Elderly with Long-Term Care Requirements.

    Science.gov (United States)

    Ogata, Soshiro; Hayashi, Chisato; Sugiura, Keiko; Hayakawa, Kazuo

    2015-01-01

    Depressive state has been reported to be significantly associated with higher-level functional capacity among community-dwelling elderly. However, few studies have investigated the associations among people with long-term care requirements. We aimed to investigate the associations between depressive state and higher-level functional capacity and obtain marginal odds ratios using propensity score analyses in people with long-term care requirements. We conducted a cross-sectional study based on participants aged ≥ 65 years (n = 545) who were community dwelling and used outpatient care services for long-term preventive care. We measured higher-level functional capacity, depressive state, and possible confounders. Then, we estimated the marginal odds ratios (i.e., the change in odds of impaired higher-level functional capacity if all versus no participants were exposed to depressive state) by logistic models using generalized linear models with the inverse probability of treatment weighting (IPTW) for propensity score and design-based standard errors. Depressive state was used as the exposure variable and higher-level functional capacity as the outcome variable. The all absolute standardized differences after the IPTW using the propensity scores were functional capacity.

  1. Nuclear Medicine Image Display. Chapter 14

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, H. [Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna (Austria)

    2014-12-15

    The final step in a medical imaging procedure is to display the image(s) on a suitable display system where it is presented to the medical specialist for diagnostic interpretation. The display of hard copy images on X ray film or photographic film has largely been replaced today by soft copy image display systems with cathode ray tube (CRT) or liquid crystal display (LCD) monitors as the image rendering device. Soft copy display requires a high quality display monitor and a certain amount of image processing to optimize the image both with respect to the properties of the display device and to some psychophysiological properties of the human visual system. A soft copy display system, therefore, consists of a display workstation providing some basic image processing functions and the display monitor as the intrinsic display device. Display devices of lower quality may be used during intermediate steps of the acquisition and analysis of a patient study. Display monitors with a quality suitable for diagnostic reading by the specialist medical doctor are called primary devices, also known as diagnostic devices. Monitors with lower quality but good enough to be used for positioning, processing of studies, presentation of images in the wards, etc. are referred to as secondary devices or clinical devices. Nuclear medicine images can be adequately displayed even for diagnostic purposes on secondary devices. However, the increasing use of X ray images on which to report jointly with images from nuclear medicine studies, such as those generated by dual modality imaging, notably by positron emission tomography (PET)/computed tomography (CT) and single photon emission computed tomography (SPECT)/CT, requires display devices capable of visualizing high resolution grey scale images at diagnostic quality, i.e. primary display devices. Both grey scale and colour display devices are used, the latter playing an important role in the display of processed nuclear medicine images and

  2. Nuclear Medicine Image Display. Chapter 14

    International Nuclear Information System (INIS)

    Bergmann, H.

    2014-01-01

    The final step in a medical imaging procedure is to display the image(s) on a suitable display system where it is presented to the medical specialist for diagnostic interpretation. The display of hard copy images on X ray film or photographic film has largely been replaced today by soft copy image display systems with cathode ray tube (CRT) or liquid crystal display (LCD) monitors as the image rendering device. Soft copy display requires a high quality display monitor and a certain amount of image processing to optimize the image both with respect to the properties of the display device and to some psychophysiological properties of the human visual system. A soft copy display system, therefore, consists of a display workstation providing some basic image processing functions and the display monitor as the intrinsic display device. Display devices of lower quality may be used during intermediate steps of the acquisition and analysis of a patient study. Display monitors with a quality suitable for diagnostic reading by the specialist medical doctor are called primary devices, also known as diagnostic devices. Monitors with lower quality but good enough to be used for positioning, processing of studies, presentation of images in the wards, etc. are referred to as secondary devices or clinical devices. Nuclear medicine images can be adequately displayed even for diagnostic purposes on secondary devices. However, the increasing use of X ray images on which to report jointly with images from nuclear medicine studies, such as those generated by dual modality imaging, notably by positron emission tomography (PET)/computed tomography (CT) and single photon emission computed tomography (SPECT)/CT, requires display devices capable of visualizing high resolution grey scale images at diagnostic quality, i.e. primary display devices. Both grey scale and colour display devices are used, the latter playing an important role in the display of processed nuclear medicine images and

  3. A deviation display method for visualising data in mobile gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kock, Peder, E-mail: Peder.Kock@med.lu.s [Department of Medical Radiation Physics, Clinical Sciences, Lund University, University Hospital, SE-221 85 Lund (Sweden); Finck, Robert R. [Swedish Radiation Protection Authority, SE-171 16 Stockholm (Sweden); Nilsson, Jonas M.C.; Ostlund, Karl; Samuelsson, Christer [Department of Medical Radiation Physics, Clinical Sciences, Lund University, University Hospital, SE-221 85 Lund (Sweden)

    2010-09-15

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded {sup 137}Cs and {sup 241}Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialisation time of about 10 min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.

  4. A deviation display method for visualising data in mobile gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Kock, Peder; Finck, Robert R.; Nilsson, Jonas M.C.; Ostlund, Karl; Samuelsson, Christer

    2010-01-01

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded 137 Cs and 241 Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialisation time of about 10 min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.

  5. Higher plasma level of STIM1, OPG are correlated with stent restenosis after PCI.

    Science.gov (United States)

    Li, Haibin; Jiang, Zhian; Liu, Xiangdong; Yang, Zhihui

    2015-01-01

    Percutaneous Coronary Intervention (PCI) is one of the most effective treatments for Coronary Heart Disease (CHD), but the high rate of In Stent Restenosis (ISR) has plagued clinicians after PCI. We aim to investigate the correlation of plasma Stromal Interaction Molecular 1 (STIM1) and Osteoprotegerin (OPG) level with stent restenosis after PCI. A total of 100 consecutive patients with Coronary Heart Disease (CHD) received PCI procedure were recruited. Coronary angiography was performed 8 months after their PCI. Then patients were divided into 2 groups: observation group was composed by patients who existing postoperative stenosis after intervention; Control group was composed by patients with no postoperative stenosis. The plasma levels of STIM, OPG in all patients were tested before and after intervention. Pearson correlation and multiple linear regression analysis were performed to analysis the correlation between STIM, OPG level and postoperative stenosis. 35 cases were divided into observation group and other 65 were divided into control group. The plasma levels of STIM, OPG have no statistical difference before their PCI procedure, but we observed higher level of High-sensitivity C-reactive protein (Hs-CRP) existed in observation group. We observed higher level of plasma STIM, OPG in observation group when compared with control group after PCI procedure (P PCI, which could provide useful information for the restenosis control after PCI.

  6. Multi-domain, higher order level set scheme for 3D image segmentation on the GPU

    DEFF Research Database (Denmark)

    Sharma, Ojaswa; Zhang, Qin; Anton, François

    2010-01-01

    to evaluate level set surfaces that are $C^2$ continuous, but are slow due to high computational burden. In this paper, we provide a higher order GPU based solver for fast and efficient segmentation of large volumetric images. We also extend the higher order method to multi-domain segmentation. Our streaming...

  7. Display systems for NPP control

    International Nuclear Information System (INIS)

    Rozov, S.S.

    1988-01-01

    Main trends in development of display systems used as the means for image displaying in NPP control systems are considered. It is shown that colour display devices appear to be the most universal means for concentrated data presentation. Along with digital means the display systems provide for high-speed response, sufficient for operative control of executive mechanisms. A conclusion is drawn that further development of display systems will move towards creation of large colour fields (on reflection base or with multicolour gas-discharge elements)

  8. Higher-level processes in the formation and application of associations during action understanding

    NARCIS (Netherlands)

    Heil, L.; Pelt, S. van; Kwisthout, J.H.P.; Rooij, I.J.E.I. van; Bekkering, H.

    2014-01-01

    The associative account described in the target article provides a viable explanation for the origin of mirror neurons. We argue here that if mirror neurons develop purely by associative learning, then they cannot by themselves explain intentional action understanding. Higher-level processes seem to

  9. LED-driven backlights for automotive displays

    Science.gov (United States)

    Strauch, Frank

    2007-09-01

    As a light source the LED has some advantage over the traditionally used fluorescence tube such as longer life or lower space consumption. Consequently customers are asking for the LED lighting design in their products. We introduced in a company owned backlight the white LED technology. This step opens the possibility to have access to the components in the display market. Instead of having a finalized display product which needs to be integrated in the head unit of a car we assemble the backlight, the glass, own electronics and the housing. A major advantage of this concept is the better control of the heat flow generated by the LEDs to the outer side because only a common housing is used for all the components. Also the requirement for slim products can be fulfilled. As always a new technology doesn't come with advantages only. An LED represents a point source compared to the well-known tube thus requiring a mixing zone for the multiple point sources when they enter a light guide. This zone can't be used in displays because of the lack of homogeneity. It's a design goal to minimize this zone which can be helped by the right choice of the LED in terms of slimness. A step ahead is the implementation of RGB LEDs because of their higher color rendering abilities. This allows for the control of the chromaticity point under temperature change but as a drawback needs a larger mixing zone.

  10. Concurrent immunomodulator therapy is associated with higher adalimumab trough levels during scheduled maintenance therapy.

    Science.gov (United States)

    Bond, Ashley; Dodd, Susanna; Fisher, Gareth; Skouras, Thomas; Subramanian, Sreedhar

    2017-02-01

    Combination therapy with infliximab and immunomodulators is superior to monotherapy, resulting in better outcomes and higher trough levels of infliximab. The role of concurrent immunomodulatory therapy on adalimumab trough levels has not been adequately investigated. We evaluated the impact of concomitant immunomodulation on adalimumab trough levels in patients on scheduled maintenance therapy. We conducted a prospective observational, cross-sectional study of all inflammatory bowel disease patients on maintenance therapy who had adalimumab trough levels measured between January 2013 and January 2016. Drug level and anti-drug antibody measurements were performed on sera using a solid phase assay. Pairwise comparison of means was used to compare trough levels in patients with and without concomitant immune modulator therapy. In total, 79 patients were included. Twenty-three patients (29.1%) were on weekly dosing whereas 56 (70.9%) were on alternate weeks. Median adalimumab trough levels were comparable in patients with and without clinical remission (6.8 μg/ml (IQR 5.6-8.1) versus 6.7 μg/ml (IQR 3.9-8.1), respectively. Patients with an elevated faecal calprotectin >250 μg/g had lower adalimumab trough levels (median 6.7, IQR 3.9-8) compared to patients with faecal calprotectin <250 μg/g (median 7.7, IQR 6.1-8.1) though this did not achieve statistical significance (p = .062). Median adalimumab trough levels among patients on concurrent immunomodulators was 7.2 μg/ml (IQR 5.7-8.1) compared to those not on concurrent immunomodulator, 6.1 μg/ml (IQR 2.7-7.7, p = .0297). Adalimumab trough levels were significantly higher in patients on concurrent immunomodulators during maintenance therapy. There was a trend towards a lower adalimumab trough level in patients with elevated calprotectin.

  11. Improved algorithm for surface display from volumetric data

    International Nuclear Information System (INIS)

    Lobregt, S.; Schaars, H.W.G.K.; OpdeBeek, J.C.A.; Zonneveld, F.W.

    1988-01-01

    A high-resolution surface display is produced from three-dimensional datasets (computed tomography or magnetic resonance imaging). Unlike other voxel-based methods, this algorithm does not show a cuberille surface structure, because the surface orientation is calculated from original gray values. The applied surface shading is a function of local orientation and position of the surface and of a virtual light source, giving a realistic impression of the surface of bone and soft tissue. The projection and shading are table driven, combining variable viewpoint and illumination conditions with speed. Other options are cutplane gray-level display and surface transparency. Combined with volume scanning, this algorithm offers powerful application possibilities

  12. Ribosome display: next-generation display technologies for production of antibodies in vitro.

    Science.gov (United States)

    He, Mingyue; Khan, Farid

    2005-06-01

    Antibodies represent an important and growing class of biologic research reagents and biopharmaceutical products. They can be used as therapeutics in a variety of diseases. With the rapid expansion of proteomic studies and biomarker discovery, there is a need for the generation of highly specific binding reagents to study the vast number of proteins encoded by the genome. Display technologies provide powerful tools for obtaining antibodies. Aside from the preservation of natural antibody repertoires, they are capable of exploiting diversity by DNA recombination to create very large libraries for selection of novel molecules. In contrast to in vivo immunization processes, display technologies allow selection of antibodies under in vitro-defined selection condition(s), resulting in enrichment of antibodies with desired properties from large populations. In addition, in vitro selection enables the isolation of antibodies against difficult antigens including self-antigens, and this can be applied to the generation of human antibodies against human targets. Display technologies can also be combined with DNA mutagenesis for antibody evolution in vitro. Some methods are amenable to automation, permitting high-throughput generation of antibodies. Ribosome display is considered as representative of the next generation of display technologies since it overcomes the limitations of cell-based display methods by using a cell-free system, offering advantages of screening larger libraries and continuously expanding new diversity during selection. Production of display-derived antibodies can be achieved by choosing one of a variety of prokaryotic and eukaryotic cell-based expression systems. In the near future, cell-free protein synthesis may be developed as an alternative for large-scale generation of antibodies.

  13. Design of the control system for full-color LED display based on MSP430 MCU

    Science.gov (United States)

    Li, Xue; Xu, Hui-juan; Qin, Ling-ling; Zheng, Long-jiang

    2013-08-01

    The LED display incorporate the micro electronic technique, computer technology and information processing as a whole, it becomes the most preponderant of a new generation of display media with the advantages of bright in color, high dynamic range, high brightness and long operating life, etc. The LED display has been widely used in the bank, securities trading, highway signs, airport and advertising, etc. According to the display color, the LED display screen is divided into monochrome screen, double color display and full color display. With the diversification of the LED display's color and the ceaseless rise of the display demands, the LED display's drive circuit and control technology also get the corresponding progress and development. The earliest monochrome screen just displaying Chinese characters, simple character or digital, so the requirements of the controller are relatively low. With the widely used of the double color LED display, the performance of its controller will also increase. In recent years, the full color LED display with three primary colors of red, green, blue and grayscale display effect has been highly attention with its rich and colorful display effect. Every true color pixel includes three son pixels of red, green, blue, using the space colour mixture to realize the multicolor. The dynamic scanning control system of LED full-color display is designed based on MSP430 microcontroller technology of the low power consumption. The gray control technology of this system used the new method of pulse width modulation (PWM) and 19 games show principle are combining. This method in meet 256 level grayscale display conditions, improves the efficiency of the LED light device, and enhances the administrative levels feels of the image. Drive circuit used 1/8 scanning constant current drive mode, and make full use of the single chip microcomputer I/O mouth resources to complete the control. The system supports text, pictures display of 256 grayscale

  14. Object Categorization in Finer Levels Relies More on Higher Spatial Frequencies and Takes Longer.

    Science.gov (United States)

    Ashtiani, Matin N; Kheradpisheh, Saeed R; Masquelier, Timothée; Ganjtabesh, Mohammad

    2017-01-01

    advantage of the superordinate (resp. basic) level to basic (resp. subordinate) level is mainly due to the computational constraints (the visual system processes higher spatial frequencies more slowly, and categorization in finer levels depends more on these higher spatial frequencies).

  15. Transgenic tobacco plants having a higher level of methionine are more sensitive to oxidative stress.

    Science.gov (United States)

    Hacham, Yael; Matityahu, Ifat; Amir, Rachel

    2017-07-01

    Methionine is an essential amino acid the low level of which limits the nutritional quality of plants. We formerly produced transgenic tobacco (Nicotiana tabacum) plants overexpressing CYSTATHIONE γ-SYNTHASE (CGS) (FA plants), methionine's main regulatory enzyme. These plants accumulate significantly higher levels of methionine compared with wild-type (WT) plants. The aim of this study was to gain more knowledge about the effect of higher methionine content on the metabolic profile of vegetative tissue and on the morphological and physiological phenotypes. FA plants exhibit slightly reduced growth, and metabolic profiling analysis shows that they have higher contents of stress-related metabolites. Despite this, FA plants were more sensitive to short- and long-term oxidative stresses. In addition, compared with WT plants and transgenic plants expressing an empty vector, the primary metabolic profile of FA was altered less during oxidative stress. Based on morphological and metabolic phenotypes, we strongly proposed that FA plants having higher levels of methionine suffer from stress under non-stress conditions. This might be one of the reasons for their lesser ability to cope with oxidative stress when it appeared. The observation that their metabolic profiling is much less responsive to stress compared with control plants indicates that the delta changes in metabolite contents between non-stress and stress conditions is important for enabling the plants to cope with stress conditions. © 2017 Scandinavian Plant Physiology Society.

  16. Event Displays for the Visualization of CMS Events

    CERN Document Server

    Jones, Christopher Duncan

    2010-01-01

    During the last year the CMS experiment engaged in consolidation of its existing event display programs. The core of the new system is based on the Fireworks event display program which was by-design directly integrated with the CMS Event Data Model (EDM) and the light version of the software framework (FWLite). The Event Visualization Environment (EVE) of the ROOT framework is used to manage a consistent set of 3D and 2D views, selection, user-feedback and user-interaction with the graphics windows; several EVE components were developed by CMS in collaboration with the ROOT project. In event display operation simple plugins are registered into the system to perform conversion from EDM collections into their visual representations which are then managed by the application. Full event navigation and filtering as well as collection-level filtering is supported. The same data-extraction principle can also be applied when Fireworks will eventually operate as a service within the full software framework.

  17. Event Display for the Visualization of CMS Events

    Science.gov (United States)

    Bauerdick, L. A. T.; Eulisse, G.; Jones, C. D.; Kovalskyi, D.; McCauley, T.; Mrak Tadel, A.; Muelmenstaedt, J.; Osborne, I.; Tadel, M.; Tu, Y.; Yagil, A.

    2011-12-01

    During the last year the CMS experiment engaged in consolidation of its existing event display programs. The core of the new system is based on the Fireworks event display program which was by-design directly integrated with the CMS Event Data Model (EDM) and the light version of the software framework (FWLite). The Event Visualization Environment (EVE) of the ROOT framework is used to manage a consistent set of 3D and 2D views, selection, user-feedback and user-interaction with the graphics windows; several EVE components were developed by CMS in collaboration with the ROOT project. In event display operation simple plugins are registered into the system to perform conversion from EDM collections into their visual representations which are then managed by the application. Full event navigation and filtering as well as collection-level filtering is supported. The same data-extraction principle can also be applied when Fireworks will eventually operate as a service within the full software framework.

  18. Event Display for the Visualization of CMS Events

    International Nuclear Information System (INIS)

    Bauerdick, L A T; Eulisse, G; Jones, C D; McCauley, T; Osborne, I; Kovalskyi, D; Tadel, A Mrak; Muelmenstaedt, J; Tadel, M; Tu, Y; Yagil, A

    2011-01-01

    During the last year the CMS experiment engaged in consolidation of its existing event display programs. The core of the new system is based on the Fireworks event display program which was by-design directly integrated with the CMS Event Data Model (EDM) and the light version of the software framework (FWLite). The Event Visualization Environment (EVE) of the ROOT framework is used to manage a consistent set of 3D and 2D views, selection, user-feedback and user-interaction with the graphics windows; several EVE components were developed by CMS in collaboration with the ROOT project. In event display operation simple plugins are registered into the system to perform conversion from EDM collections into their visual representations which are then managed by the application. Full event navigation and filtering as well as collection-level filtering is supported. The same data-extraction principle can also be applied when Fireworks will eventually operate as a service within the full software framework.

  19. Large-screen display industry: market and technology trends for direct view and projection displays

    Science.gov (United States)

    Castellano, Joseph A.; Mentley, David E.

    1996-03-01

    Large screen information displays are defined as dynamic electronic displays that can be viewed by more than one person and are at least 2-feet wide. These large area displays for public viewing provide convenience, entertainment, security, and efficiency to the viewers. There are numerous uses for large screen information displays including those in advertising, transportation, traffic control, conference room presentations, computer aided design, banking, and military command/control. A noticeable characteristic of the large screen display market is the interchangeability of display types. For any given application, the user can usually choose from at least three alternative technologies, and sometimes from many more. Some display types have features that make them suitable for specific applications due to temperature, brightness, power consumption, or other such characteristic. The overall worldwide unit consumption of large screen information displays of all types and for all applications (excluding consumer TV) will increase from 401,109 units in 1995 to 655,797 units in 2002. On a unit consumption basis, applications in business and education represent the largest share of unit consumption over this time period; in 1995, this application represented 69.7% of the total. The market (value of shipments) will grow from DOL3.1 billion in 1995 to DOL3.9 billion in 2002. The market will be dominated by front LCD projectors and LCD overhead projector plates.

  20. The mouse liver displays daily rhythms in the metabolism of phospholipids and in the activity of lipid synthesizing enzymes.

    Science.gov (United States)

    Gorné, Lucas D; Acosta-Rodríguez, Victoria A; Pasquaré, Susana J; Salvador, Gabriela A; Giusto, Norma M; Guido, Mario Eduardo

    2015-02-01

    The circadian system involves central and peripheral oscillators regulating temporally biochemical processes including lipid metabolism; their disruption leads to severe metabolic diseases (obesity, diabetes, etc). Here, we investigated the temporal regulation of glycerophospholipid (GPL) synthesis in mouse liver, a well-known peripheral oscillator. Mice were synchronized to a 12:12 h light-dark (LD) cycle and then released to constant darkness with food ad libitum. Livers collected at different times exhibited a daily rhythmicity in some individual GPL content with highest levels during the subjective day. The activity of GPL-synthesizing/remodeling enzymes: phosphatidate phosphohydrolase 1 (PAP-1/lipin) and lysophospholipid acyltransferases (LPLATs) also displayed significant variations, with higher levels during the subjective day and at dusk. We evaluated the temporal regulation of expression and activity of phosphatidylcholine (PC) synthesizing enzymes. PC is mainly synthesized through the Kennedy pathway with Choline Kinase (ChoK) as a key regulatory enzyme or through the phosphatidylethanolamine (PE) N-methyltransferase (PEMT) pathway. The PC/PE content ratio exhibited a daily variation with lowest levels at night, while ChoKα and PEMT mRNA expression displayed maximal levels at nocturnal phases. Our results demonstrate that mouse liver GPL metabolism oscillates rhythmically with a precise temporal control in the expression and/or activity of specific enzymes.

  1. LMDS Lightweight Modular Display System.

    Science.gov (United States)

    1982-02-16

    based on standard functions. This means that the cost to produce a particular display function can be met in the most economical fashion and at the same...not mean that the NTDS interface would be eliminated. What is anticipated is the use of ETHERNET at a low level of system interface, ie internal to...GENERATOR dSYMBOL GEN eCOMMUNICATION 3-2 The architecture of the unit’s (fig 3-4) input circuitry is based on a video table look-up ROM. The function

  2. Digital Holography and Three-Dimensional Display Principles and Applications

    CERN Document Server

    Poon, Ting-Chung

    2006-01-01

    About the Book Digital (or electronic) holography and its application to 3-D display is one of the formidable problems of evolving areas of high technology that has been receiving great attention in recent years. The realization of life-size interactive 3-D displays has been a seemingly unobtainable goal. Technology is not quite at that level yet, but advances in 3-D display now allow us to take important steps toward the achievement of this objective. The reader is presented with the state-of-the-art developments in both digital holography and 3-D display techniques. The book contains a large amount of research material as well as reviews, new ideas and insights that will be useful for graduate students, scientists, and engineers working in the field. About the Editor Ting-Chung Poon is a professor at Virgina Tech in the Bradley Department of Electrical and Computer Engineering, where he is also Director of the Optical Image Processing Laboratory. His research interests include acousto-optics, hybrid (optica...

  3. Automatic generation of computer programs servicing TFTR console displays

    International Nuclear Information System (INIS)

    Eisenberg, H.

    1983-01-01

    A number of alternatives were considered in providing programs to support the several hundred displays required for control and monitoring of TFTR equipment. Since similar functions were performed, an automated method of creating programs was suggested. The complexity of a single program servicing as many as thirty consoles mitigated against that approach. Similarly, creation of a syntactic language while elegant, was deemed to be too time consuming, and had the disadvantage of requiring a working knowledge of the language on a programming level. It was elected to pursue a method of generating an individual program to service a particular display. A feasibility study was conducted and the Control and Monitor Display Generator system (CMDG) was developed. A Control and Monitor Display Service Program (CMDS) provides a means of performing monitor and control functions for devices associated with TFTR subsystems, as well as other user functions, via TFTR Control Consoles. This paper discusses the specific capabilities provided by CMDS in a usage context, as well as the mechanics of implementation

  4. Proposed evaluation framework for assessing operator performance with multisensor displays

    Science.gov (United States)

    Foyle, David C.

    1992-01-01

    Despite aggressive work on the development of sensor fusion algorithms and techniques, no formal evaluation procedures have been proposed. Based on existing integration models in the literature, an evaluation framework is developed to assess an operator's ability to use multisensor, or sensor fusion, displays. The proposed evaluation framework for evaluating the operator's ability to use such systems is a normative approach: The operator's performance with the sensor fusion display can be compared to the models' predictions based on the operator's performance when viewing the original sensor displays prior to fusion. This allows for the determination as to when a sensor fusion system leads to: 1) poorer performance than one of the original sensor displays (clearly an undesirable system in which the fused sensor system causes some distortion or interference); 2) better performance than with either single sensor system alone, but at a sub-optimal (compared to the model predictions) level; 3) optimal performance (compared to model predictions); or, 4) super-optimal performance, which may occur if the operator were able to use some highly diagnostic 'emergent features' in the sensor fusion display, which were unavailable in the original sensor displays. An experiment demonstrating the usefulness of the proposed evaluation framework is discussed.

  5. Nonlinear mapping of the luminance in dual-layer high dynamic range displays

    Science.gov (United States)

    Guarnieri, Gabriele; Ramponi, Giovanni; Bonfiglio, Silvio; Albani, Luigi

    2009-02-01

    It has long been known that the human visual system (HVS) has a nonlinear response to luminance. This nonlinearity can be quantified using the concept of just noticeable difference (JND), which represents the minimum amplitude of a specified test pattern an average observer can discern from a uniform background. The JND depends on the background luminance following a threshold versus intensity (TVI) function. It is possible to define a curve which maps physical luminances into a perceptually linearized domain. This mapping can be used to optimize a digital encoding, by minimizing the visibility of quantization noise. It is also commonly used in medical applications to display images adapting to the characteristics of the display device. High dynamic range (HDR) displays, which are beginning to appear on the market, can display luminance levels outside the range in which most standard mapping curves are defined. In particular, dual-layer LCD displays are able to extend the gamut of luminance offered by conventional liquid crystals towards the black region; in such areas suitable and HVS-compliant luminance transformations need to be determined. In this paper we propose a method, which is primarily targeted to the extension of the DICOM curve used in medical imaging, but also has a more general application. The method can be modified in order to compensate for the ambient light, which can be significantly greater than the black level of an HDR display and consequently reduce the visibility of the details in dark areas.

  6. Evaluating the Effect of Display Realism on Natural Resource Decision Making

    Science.gov (United States)

    Chong, Steven S.

    2018-05-01

    Geographic information systems (GIS) facilitate location-based decision making. Despite the improved availability of GIS software to non-professionals, training in cartographic design has not followed suit. Prior research indicates that when presented with map choices, users are influenced by naïve realism, a preference for realistic displays cotaining irrelevant, extraneous details, leading to decreased task efficiency. This study investigated the role of naïve realism in decision making for natural resource management, a field that often employs geospatial tools. Data was collected through a GIS user ability test, a questionnaire and direct observation. Forty volunteer expert and non-expert resource managers evaluated the suitability of different sites for a land management scenario. Each participant was tested on two map display treatments containing different levels of realism - a simpler 2D display and a more complex 3D display - to compare task performance. Performance was measured by task accuracy and task completion time. User perceptions and preferences about the displays were also recorded. Display realism had an impact on performance and there were indications naïve realism was present. Users completed tasks significantly faster on the 2D display and many individuals misjudged which display they were most accurate or fastest with. The results are informative for designing information systems containing interactive maps, particularly for resource management applications. The results also suggest that the order displays were presented had a significant effect and may have implications for teaching users map-based tasks.

  7. Physiological Costs of Repetitive Courtship Displays in Cockroaches Handicap Locomotor Performance

    Science.gov (United States)

    Mowles, Sophie L.; Jepson, Natalie M.

    2015-01-01

    Courtship displays are typically thought to have evolved via female choice, whereby females select mates based on the characteristics of a display that is expected to honestly reflect some aspect of the male’s quality. Honesty is typically enforced by mechanistic costs and constraints that limit the level at which a display can be performed. It is becoming increasingly apparent that these costs may be energetic costs involved in the production of dynamic, often repetitive displays. A female attending to such a display may thus be assessing the physical fitness of a male as an index of his quality. Such assessment would provide information on his current physical quality as well as his ability to carry out other demanding activities, qualities with which a choosy female should want to provision her offspring. In the current study we use courtship interactions in the Cuban burrowing cockroach, Byrsotria fumigata to directly test whether courtship is associated with a signaler’s performance capacity. Males that had produced courtship displays achieved significantly lower speeds and distances in locomotor trials than non-courting control males. We also found that females mated more readily with males that produced a more vigorous display. Thus, males of this species have developed a strategy where they produce a demanding courtship display, while females choose males based on their ability to produce this display. Courtship displays in many taxa often involve dynamic repetitive actions and as such, signals of stamina in courtship may be more widespread than previously thought. PMID:26606147

  8. Models, controls, and levels of semiotic autonomy

    Energy Technology Data Exchange (ETDEWEB)

    Joslyn, C.

    1998-12-01

    In this paper the authors consider forms of autonomy, forms of semiotic systems, and any necessary relations among them. Levels of autonomy are identified as levels of system identity, from adiabatic closure to disintegration. Forms of autonomy or closure in systems are also recognized, including physical, dynamical, functional, and semiotic. Models and controls are canonical linear and circular (closed) semiotic relations respectively. They conclude that only at higher levels of autonomy do semiotic properties become necessary. In particular, all control systems display at least a minimal degree of semiotic autonomy; and all systems with sufficiently interesting functional autonomy are semiotically related to their environments.

  9. Physical evaluation of color and monochrome medical displays using an imaging colorimeter

    Science.gov (United States)

    Roehrig, Hans; Gu, Xiliang; Fan, Jiahua

    2013-03-01

    This paper presents an approach to physical evaluation of color and monochrome medical grade displays using an imaging colorimeter. The purpose of this study was to examine the influence of medical display types, monochrome or color at the same maximum luminance settings, on diagnostic performance. The focus was on the measurements of physical characteristics including spatial resolution and noise performance, which we believed could affect the clinical performance. Specifically, Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) were evaluated and compared at different digital driving levels (DDL) between two EIZO displays.

  10. Scalable Resolution Display Walls

    KAUST Repository

    Leigh, Jason; Johnson, Andrew; Renambot, Luc; Peterka, Tom; Jeong, Byungil; Sandin, Daniel J.; Talandis, Jonas; Jagodic, Ratko; Nam, Sungwon; Hur, Hyejung; Sun, Yiwen

    2013-01-01

    This article will describe the progress since 2000 on research and development in 2-D and 3-D scalable resolution display walls that are built from tiling individual lower resolution flat panel displays. The article will describe approaches and trends in display hardware construction, middleware architecture, and user-interaction design. The article will also highlight examples of use cases and the benefits the technology has brought to their respective disciplines. © 1963-2012 IEEE.

  11. Visual search asymmetries within color-coded and intensity-coded displays.

    Science.gov (United States)

    Yamani, Yusuke; McCarley, Jason S

    2010-06-01

    Color and intensity coding provide perceptual cues to segregate categories of objects within a visual display, allowing operators to search more efficiently for needed information. Even within a perceptually distinct subset of display elements, however, it may often be useful to prioritize items representing urgent or task-critical information. The design of symbology to produce search asymmetries (Treisman & Souther, 1985) offers a potential technique for doing this, but it is not obvious from existing models of search that an asymmetry observed in the absence of extraneous visual stimuli will persist within a complex color- or intensity-coded display. To address this issue, in the current study we measured the strength of a visual search asymmetry within displays containing color- or intensity-coded extraneous items. The asymmetry persisted strongly in the presence of extraneous items that were drawn in a different color (Experiment 1) or a lower contrast (Experiment 2) than the search-relevant items, with the targets favored by the search asymmetry producing highly efficient search. The asymmetry was attenuated but not eliminated when extraneous items were drawn in a higher contrast than search-relevant items (Experiment 3). Results imply that the coding of symbology to exploit visual search asymmetries can facilitate visual search for high-priority items even within color- or intensity-coded displays. PsycINFO Database Record (c) 2010 APA, all rights reserved.

  12. Bioadsorption of cadmium ion by cell surface-engineered yeasts displaying metallothionein and hexa-His

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, K.; Ueda, M. [Lab. of Applied Biological Chemistry, Kyoto Univ., Yoshida, Kyoto (Japan)

    2004-07-01

    The Cd{sup 2+}-chelating abilities of yeast metallothionein (YMT) and hexa-His displayed on the yeast-cell surface were compared. Display of YMT and hexa-His by {alpha}-agglutinin-based cell-surface engineering was confirmed by immunofluorescent labeling. Surface-engineered yeast cells with YMT and hexa-His fused in tandem showed superior cell-surface adsorption and recovery of Cd{sup 2+} under EDTA treatment on the cell surface than hexa-His-displaying cells. YMT was demonstrated to be more effective than hexa-His for the adsorption of Cd{sup 2+}. Yeast cells displaying YMT and/or hexa-His exhibited a higher potential for the adsorption of Cd{sup 2+} than Escherichia coli cells displaying these molecules. In order to investigate the effect of the displayed YMT and hexa-His on sensitivity to toxic Cd{sup 2+}, growth in Cd{sup 2+}-containing liquid medium was monitored. Unlike hexa-His-displaying cells, cells displaying YMT and hexa-His fused in tandem induced resistance to Cd{sup 2+} through active and enhanced adsorption of toxic Cd{sup 2+}. These results indicate that YMT-displaying yeast cells are a unique bioadsorbent with a functional chelating ability superior to that of E. coli. (orig.)

  13. Corticosteroid receptor expression in a teleost fish that displays alternative male reproductive tactics.

    Science.gov (United States)

    Arterbery, Adam S; Deitcher, David L; Bass, Andrew H

    2010-01-01

    Corticosteroid signaling mechanisms mediate a wide range of adaptive physiological responses, including those essential to reproduction. Here, we investigated the presence and relative abundance of corticosteroid receptors during the breeding season in the plainfin midshipman fish (Porichthys notatus), a species that has two male reproductive morphs. Only type I "singing" males acoustically court females and aggressively defend a nest site, whereas type II "sneaker" males steal fertilizations from nesting type I males. Cloning and sequencing first identified glucocorticoid (GR) and mineralocorticoid (MR) receptors in midshipman that exhibited high sequence identity with other vertebrate GRs and MRs. Absolute-quantitative real-time PCR then revealed higher levels of GR in the central nervous system (CNS) of type II males than type I males and females, while GR levels in the sound-producing, vocal muscle and the liver were higher in type I males than type II males and females. MR expression was also greater in the CNS of type II males than type I males or females, but the differences were more modest in magnitude. Lastly, plasma levels of cortisol, the main glucocorticoid in teleosts, were 2- to 3-fold greater in type II males compared to type I males. Together, the results suggest a link between corticosteroid regulation and physiological and behavioral variation in a teleost fish that displays male alternative reproductive tactics.

  14. The Neuromuscular Qualities of Higher- and Lower-Level Mixed-Martial-Arts Competitors.

    Science.gov (United States)

    James, Lachlan P; Beckman, Emma M; Kelly, Vincent G; Haff, G Gregory

    2017-05-01

    To determine whether the maximal strength, impulse, and power characteristics of competitive mixed-martial-arts (MMA) athletes differ according to competition level. Twenty-nine male semiprofessional and amateur MMA competitors were stratified into either higher-level (HL) or lower-level (LL) performers on the basis of competition grade and success. The 1-repetition-maximum (1RM) squat was used to assess lower-body dynamic strength, and a spectrum of impulse, power, force, and velocity variables were evaluated during an incremental-load jump squat. In addition, participants performed an isometric midthigh pull (IMTP) and 1RM bench press to determine whole-body isometric force and upper-body dynamic strength capabilities, respectively. All force and power variables were expressed relative to body mass (BM). The HL competitors produced significantly superior values across a multitude of measures. These included 1RM squat strength (1.84 ± 0.23 vs 1.56 ± 0.24 kg BM; P = .003), in addition to performance in the incremental-load jump squat that revealed greater peak power (P = .005-.002), force (P = .002-.004), and velocity (P = .002-.03) at each load. Higher measures of impulse (P = .01-.04) were noted in a number of conditions. Average power (P = .002-.02) and velocity (P = .01-.04) at all loads in addition to a series of rate-dependent measures were also superior in the HL group (P = .005-.02). The HL competitors' 1RM bench-press values approached significantly greater levels (P = .056) than the LL group's, but IMTP performance did not differ between groups. Maximal lower-body neuromuscular capabilities are key attributes distinguishing HL from LL MMA competitors. This information can be used to inform evidenced-based training and performance-monitoring practices.

  15. Study on the visibility of an electroluminescent display for automobiles; Jidoshayo EL display no shininsei

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, N; Harada, M; Idogaki, T [Denso Corp., Aichi (Japan)

    1997-10-01

    This report explores the visibility of an Electroluminescent (EL) display for automotive use. Displays for automobiles are exposed to the direct rays of the sun and forced to operate in wide temperature range. Therefore, luminous flux density by the lighting on EL display panel and operating environment temperature must be considered for the visibility evaluation. Sensory evaluation on the visibility and physical measurements such as contrast, chromaticity difference in accordance with the viewing angle change indicate that the visibility of the EL display for automobiles is advantageous over other displays. 6 refs., 11 figs., 1 tab.

  16. Laser illuminated flat panel display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T.

    1995-12-31

    A 10 inch laser illuminated flat panel Planar Optic Display (POD) screen has been constructed and tested. This POD screen technology is an entirely new concept in display technology. Although the initial display is flat and made of glass, this technology lends itself to applications where a plastic display might be wrapped around the viewer. The display screen is comprised of hundreds of planar optical waveguides where each glass waveguide represents a vertical line of resolution. A black cladding layer, having a lower index of refraction, is placed between each waveguide layer. Since the cladding makes the screen surface black, the contrast is high. The prototype display is 9 inches wide by 5 inches high and approximately I inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  17. OLED displays and lighting

    CERN Document Server

    Koden, Mitsuhiro

    2017-01-01

    Organic light-emitting diodes (OLEDs) have emerged as the leading technology for the new display and lighting market. OLEDs are solid-state devices composed of thin films of organic molecules that create light with the application of electricity. OLEDs can provide brighter, crisper displays on electronic devices and use less power than conventional light-emitting diodes (LEDs) or liquid crystal displays (LCDs) used today. This book covers both the fundamentals and practical applications of flat and flexible OLEDs.

  18. Why do French civil-law countries have higher levels of financial efficiency?

    OpenAIRE

    Asongu Simplice

    2011-01-01

    The dominance of English common-law countries in prospects for financial development in the legal-origins debate has been debunked by recent findings. Using exchange rate regimes and economic/monetary integration oriented hypotheses, this paper proposes an “inflation uncertainty theory” in providing theoretical justification and empirical validity as to why French civil-law countries have higher levels of financial allocation efficiency. Inflation uncertainty, typical of floating exchange rat...

  19. High performance visual display for HENP detectors

    International Nuclear Information System (INIS)

    McGuigan, Michael; Smith, Gordon; Spiletic, John; Fine, Valeri; Nevski, Pavel

    2001-01-01

    A high end visual display for High Energy Nuclear Physics (HENP) detectors is necessary because of the sheer size and complexity of the detector. For BNL this display will be of special interest because of STAR and ATLAS. To load, rotate, query, and debug simulation code with a modern detector simply takes too long even on a powerful work station. To visualize the HENP detectors with maximal performance we have developed software with the following characteristics. We develop a visual display of HENP detectors on BNL multiprocessor visualization server at multiple level of detail. We work with general and generic detector framework consistent with ROOT, GAUDI etc, to avoid conflicting with the many graphic development groups associated with specific detectors like STAR and ATLAS. We develop advanced OpenGL features such as transparency and polarized stereoscopy. We enable collaborative viewing of detector and events by directly running the analysis in BNL stereoscopic theatre. We construct enhanced interactive control, including the ability to slice, search and mark areas of the detector. We incorporate the ability to make a high quality still image of a view of the detector and the ability to generate animations and a fly through of the detector and output these to MPEG or VRML models. We develop data compression hardware and software so that remote interactive visualization will be possible among dispersed collaborators. We obtain real time visual display for events accumulated during simulations

  20. Dengue-Immune Humans Have Higher Levels of Complement-Independent Enhancing Antibody than Complement-Dependent Neutralizing Antibody.

    Science.gov (United States)

    Yamanaka, Atsushi; Konishi, Eiji

    2017-09-25

    Dengue is the most important arboviral disease worldwide. We previously reported that most inhabitants of dengue-endemic countries who are naturally immune to the disease have infection-enhancing antibodies whose in vitro activity does not decrease in the presence of complement (complement-independent enhancing antibodies, or CiEAb). Here, we compared levels of CiEAb and complement-dependent neutralizing antibodies (CdNAb) in dengue-immune humans. A typical antibody dose-response pattern obtained in our assay system to measure the balance between neutralizing and enhancing antibodies showed both neutralizing and enhancing activities depending on serum dilution factor. The addition of complement to the assay system increased the activity of neutralizing antibodies at lower dilutions, indicating the presence of CdNAb. In contrast, similar dose-response curves were obtained with and without complement at higher dilutions, indicating higher levels of CiEAb than CdNAb. For experimental support for the higher CiEAb levels, a cocktail of mouse monoclonal antibodies against dengue virus type 1 was prepared. The antibody dose-response curves obtained in this assay, with or without complement, were similar to those obtained with human serum samples when a high proportion of D1-V-3H12 (an antibody exhibiting only enhancing activity and thus a model for CiEAb) was used in the cocktail. This study revealed higher-level induction of CiEAb than CdNAb in humans naturally infected with dengue viruses.

  1. Dichroic Liquid Crystal Displays

    Science.gov (United States)

    Bahadur, Birendra

    The following sections are included: * INTRODUCTION * DICHROIC DYES * Chemical Structure * Chemical and Photochemical Stability * THEORETICAL MODELLING * DEFECTS CAUSED BY PROLONGED LIGHT IRRADIATION * CHEMICAL STRUCTURE AND PHOTOSTABILITY * OTHER PARAMETERS AFFECTING PHOTOSTABILITY * CELL PREPARATION * DICHROIC PARAMETERS AND THEIR MEASUREMENTS * Order Parameter and Dichroic Ratio Of Dyes * Absorbance, Order Parameter and Dichroic Ratio Measurements * IMPACT OF DYE STRUCTURE AND LIQUID CRYSTAL HOST ON PHYSICAL PROPERTIES OF A DICHROIC MIXTURE * Order Parameter and Dichroic Ratio * EFFECT OF LENGTH OF DICHROIC DYES ON THE ORDER PARAMETER * EFFECT OF THE BREADTH OF DYE ON THE ORDER PARAMETER * EFFECT OF THE HOST ON THE ORDER PARAMETER * TEMPERATURE VARIATION OF THE ORDER PARAMETER OF DYES IN A LIQUID CRYSTAL HOST * IMPACT OF DYE CONCENTRATION ON THE ORDER PARAMETER * Temperature Range * Viscosity * Dielectric Constant and Anisotropy * Refractive Indices and Birefringence * solubility43,153-156 * Absorption Wavelength and Auxochromic Groups * Molecular Engineering of Dichroic Dyes * OPTICAL, ELECTRO-OPTICAL AND LIFE PARAMETERS * Colour And CIE Colour space120,160-166 * CIE 1931 COLOUR SPACE * CIE 1976 CHROMATICITY DIAGRAM * CIE UNIFORM COLOUR SPACES & COLOUR DIFFERENCE FORMULAE120,160-166 * Electro-Optical Parameters120 * LUMINANCE * CONTRAST AND CONTRAST RATIO * SWITCHING SPEED * Life Parameters and Failure Modes * DICHROIC MIXTURE FORMULATION * Monochrome Mixture * Black Mixture * ACHROMATIC BLACK MIXTURE FOR HEILMEIER DISPLAYS * Effect of Illuminant on Display Colour * Colour of the Field-On State * Effect of Dye Linewidth * Optimum Centroid Wavelengths * Effect of Dye Concentration * Mixture Formulation Using More Than Three Dyes * ACHROMATIC MIXTURE FOR WHITE-TAYLOR TYPE DISPLAYS * HEILMEIER DISPLAYS * Theoretical Modelling * Threshold Characteristic * Effects of Dye Concentration on Electro-optical Parameters * Effect of Cholesteric Doping * Effect of Alignment

  2. Assessment of display performance for medical imaging systems: Executive summary of AAPM TG18 report

    International Nuclear Information System (INIS)

    Samei, Ehsan; Badano, Aldo; Chakraborty, Dev

    2005-01-01

    Digital imaging provides an effective means to electronically acquire, archive, distribute, and view medical images. Medical imaging display stations are an integral part of these operations. Therefore, it is vitally important to assure that electronic display devices do not compromise image quality and ultimately patient care. The AAPM Task Group 18 (TG18) recently published guidelines and acceptance criteria for acceptance testing and quality control of medical display devices. This paper is an executive summary of the TG18 report. TG18 guidelines include visual, quantitative, and advanced testing methodologies for primary and secondary class display devices. The characteristics, tested in conjunction with specially designed test patterns (i.e., TG18 patterns), include reflection, geometric distortion, luminance, the spatial and angular dependencies of luminance, resolution, noise, glare, chromaticity, and display artifacts. Geometric distortions are evaluated by linear measurements of the TG18-QC test pattern, which should render distortion coefficients less than 2%/5% for primary/secondary displays, respectively. Reflection measurements include specular and diffuse reflection coefficients from which the maximum allowable ambient lighting is determined such that contrast degradation due to display reflection remains below a 20% limit and the level of ambient luminance (L amb ) does not unduly compromise luminance ratio (LR) and contrast at low luminance levels. Luminance evaluation relies on visual assessment of low contrast features in the TG18-CT and TG18-MP test patterns, or quantitative measurements at 18 distinct luminance levels of the TG18-LN test patterns. The major acceptable criteria for primary/secondary displays are maximum luminance of greater than 170/100 cd/m 2 , LR of greater than 250/100, and contrast conformance to that of the grayscale standard display function (GSDF) of better than 10%/20%, respectively. The angular response is tested to

  3. Google Glass Glare: disability glare produced by a head-mounted visual display.

    Science.gov (United States)

    Longley, Chris; Whitaker, David

    2016-03-01

    Head mounted displays are a type of wearable technology - a market that is projected to expand rapidly over the coming years. Probably the most well known example is the device Google Glass (or 'Glass'). Here we investigate the extent to which the device display can interfere with normal visual function by producing monocular disability glare. Contrast sensitivity was measured in two normally sighted participants, 32 and 52 years of age. Data were recorded for the right eye, the left eye and then again in a binocular condition. Measurements were taken both with and without the Glass in place, across a range of stimulus luminance levels using a two-alternative forced-choice methodology. The device produced a significant reduction in contrast sensitivity in the right eye (>0.5 log units). The level of disability glare increased as stimulus luminance was reduced in a manner consistent with intraocular light scatter, resulting in a veiling retinal illuminance. Sensitivity in the left eye was unaffected. A significant reduction in binocular contrast sensitivity occurred at lower luminance levels due to a loss of binocular summation, although binocular sensitivity was not found to fall below the sensitivity of the better monocular level (binocular inhibition). Head mounted displays such as Google Glass have the potential to cause significant disability glare in the eye exposed to the visual display, particularly under conditions of low luminance. They can also cause a more modest binocular reduction in sensitivity by eliminating the benefits of binocular summation. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.

  4. Higher serum levels of rheumatoid factor and anti-nuclear antibodies in helicobacter pylori-infected peptic ulcer patients.

    Science.gov (United States)

    Jafarzadeh, Abdollah; Nemati, Maryam; Rezayati, Mohammad Taghi; Nabizadeh, Mansooreh; Ebrahimi, Medhi

    2013-07-01

    H. pylori infection has been associated with some autoimmune disorders. The aim of this study was to evaluate the serum concentrations of rheumatoid factor and anti-nuclear antibodies in H. pylori-infected peptic ulcer patients, H. pylori-infected asymptomatic carriers and a healthy control group. A Total of 100 H. pylori-infected peptic ulcer patients, 65 asymptomatic carriers and 30 healthy H. pylori-negative subjects (as a control group) were enrolled into study. Serum samples of participants tested for the levels of rheumatoid factor and anti-nuclear antibodies by use of ELISA. The mean serum levels of rheumatoid factor and anti-nuclear antibodies in peptic ulcer group was significantly higher in comparison to the control group (ppeptic ulcer patients and asymptomatic carriers groups regarding the mean serum levels of rheumatoid factor and anti-nuclear antibodies. The mean serum levels of rheumatoid factor in men with peptic ulcer was significantly higher compared to the group of healthy men (ppeptic ulcer patients or asymptomatic carriers groups, the mean serum levels of rheumatoid factor was higher than that in healthy women, but the differences were not statistically significant. Also, no significant differences were observed between men and women with peptic ulcer, asymptomatic carriers control groups based on the serum levels of anti-nuclear antibodies. The results showed higher serum levels of rheumatoid factor and anti-nuclear antibodies in H. pylori-infected patients with peptic ulcer disease which represent the H. pylori-related immune disturbance in these patients. Additional follow-up studies are necessary to clarify the clinical significance of these autoantibodies in patients with H. pylori infection.

  5. BMI mediates the association between low educational level and higher blood pressure during pregnancy in Japan.

    Science.gov (United States)

    Jwa, Seung Chik; Fujiwara, Takeo; Hata, Akira; Arata, Naoko; Sago, Haruhiko; Ohya, Yukihiro

    2013-04-25

    Research investigating the association between socioeconomic status (SES) and blood pressure (BP) during pregnancy is limited and its underlying pathway is unknown. The aim of this study was to investigate the mediators of the association between educational level as an indicator of the SES and BP in early and mid-pregnancy among Japanese women. Nine hundred and twenty-three pregnant women in whom BP was measured before 16 weeks and at 20 weeks of gestation were enrolled in this study. Maternal educational levels were categorized into three groups: high (university or higher), mid (junior college), and low (junior high school, high school, or vocational training school). The low educational group had higher systolic (low vs. high, difference = 2.39 mmHg, 95% confidence interval [CI]: 0.59 to 4.19) and diastolic BP levels (low vs. high, difference = 0.74 mmHg, 95% CI: -0.52 to 1.99) in early pregnancy. However, the same associations were not found after adjustment for pre-pregnancy body mass index (BMI). BP reduction was observed in mid-pregnancy in all three educational groups and there was no association between educational level and pregnancy-induced hypertension. In Japanese women, the low educational group showed higher BP during pregnancy than the mid or high educational groups. Pre-pregnancy BMI mediates the association between educational level and BP.

  6. Understanding the Relative Contributions of Lower-Level Word Processes, Higher-Level Processes, and Working Memory to Reading Comprehension Performance in Proficient Adult Readers

    Science.gov (United States)

    Hannon, Brenda

    2012-01-01

    Although a considerable amount of evidence has been amassed regarding the contributions of lower-level word processes, higher-level processes, and working memory to reading comprehension, little is known about the relationships among these sources of individual differences or their relative contributions to reading comprehension performance. This…

  7. Lower placental growth factor and higher free β-hCG and PAPP-A levels in the fetal circulation of near-term pregnancies complicated with severe preeclampsia.

    Science.gov (United States)

    Paredes, Verónica; Espinoza-Caicedo, Jasson A; Salazar-Pousada, Danny; Escobar, Gustavo S; Pérez-López, Faustino R; Chedraui, Peter

    2017-01-01

    An imbalance between anti- and angiogenic factors during early placentation is key for the development of preeclampsia. Nevertheless, the majority of studies addressing this issue relate to maternal blood and not the fetal circulation. To measure placental growth factor (PlGF), free beta human chorionic gonadotropin (β-hCG), and pregnancy-associated plasma protein-A (PAPP-A) levels in the fetal circulation of near-term pregnancies complicated with severe preeclampsia (n = 20), and their controls matched for parity, and maternal and gestational age. Upon delivery, a blood sample was withdrawn from the umbilical artery and vein of each case and its control in order to measure the proposed analytes using direct fluoroimmunoassay. Preeclampsia cases showed significantly lower median PlGF levels in fetal circulation as compared to controls (25.2 versus 36.9 and 23.6 versus 33.9 pg/mL, artery and vein, respectively, p < 0.05). Contrarily, cases displayed higher concentrations of PAPP-A (1024.0 versus 720.9 [median] and 1027.0 ± 298.4 versus 690.3 ± 401.9 mIU/L, artery and vein, respectively, p < 0.05), and free β-hCG (mean: 33.9 ± 4.3 versus 17.2 ± 4.0 and 30.1 ± 5.2 versus 13.7 ± 3.3 ng/mL, artery, and vein respectively, p < 0.05). Lower PlGF and higher PAPP-A and free β-hCG levels were found in the fetal circulation of near-term severe preeclamptic pregnancies. There is a need for more research in this regard.

  8. Procedure and information displays in advanced nuclear control rooms: experimental evaluation of an integrated design.

    Science.gov (United States)

    Chen, Yue; Gao, Qin; Song, Fei; Li, Zhizhong; Wang, Yufan

    2017-08-01

    In the main control rooms of nuclear power plants, operators frequently have to switch between procedure displays and system information displays. In this study, we proposed an operation-unit-based integrated design, which combines the two displays to facilitate the synthesis of information. We grouped actions that complete a single goal into operation units and showed these operation units on the displays of system states. In addition, we used different levels of visual salience to highlight the current unit and provided a list of execution history records. A laboratory experiment, with 42 students performing a simulated procedure to deal with unexpected high pressuriser level, was conducted to compare this design against an action-based integrated design and the existing separated-displays design. The results indicate that our operation-unit-based integrated design yields the best performance in terms of time and completion rate and helped more participants to detect unexpected system failures. Practitioner Summary: In current nuclear control rooms, operators frequently have to switch between procedure and system information displays. We developed an integrated design that incorporates procedure information into system displays. A laboratory study showed that the proposed design significantly improved participants' performance and increased the probability of detecting unexpected system failures.

  9. Crosstalk evaluation in stereoscopic displays

    NARCIS (Netherlands)

    Wang, L.; Teunissen, C.; Tu, Yan; Chen, Li; Zhang, P.; Zhang, T.; Heynderickx, I.E.J.

    2011-01-01

    Substantial progress in liquid-crystal display and polarization film technology has enabled several types of stereoscopic displays. Despite all progress, some image distortions still exist in these 3-D displays, of which interocular crosstalk - light leakage of the image for one eye to the other eye

  10. Implementing CLT at Higher Secondary Level in Bangladesh: A Review of Change Management

    Science.gov (United States)

    Rahman, Md Shidur

    2015-01-01

    CLT (Communicative Language Teaching) was substituted for GTM (Grammar Translation Method) at higher secondary level in Bangladesh in 2001. This replacement of ELT method was a significant change in the English curriculum. This study aimed to determine that the mismanagement of the change is a prime cause of not getting expected CLT outcomes at…

  11. Consortium for military LCD display procurement

    Science.gov (United States)

    Echols, Gregg

    2002-08-01

    International Display Consortium (IDC) is the joining together of display companies to combined their buying power and obtained favorable terms with a major LCD manufacturer. Consolidating the buying power and grouping the demand enables the rugged display industry of avionics, ground vehicles, and ship based display manufacturers to have unencumbered access to high performance AMLCDs while greatly reducing risk and lowering cost. With an unrestricted supply of AMLCD displays, the consortium members have total control of their risk, cost, deliveries and added value partners. Every display manufacturer desires a very close relationship with a display vender. With IDC each consortium member achieves a close relationship. Consortium members enjoy cost effective access to high performance, industry standard sized LCD panels, and modified commercial displays with 100 degree C clearing points and portrait configurations. Consortium members also enjoy proposal support, technical support and long-term support.

  12. Super high precision 200 ppi liquid crystal display series; Chokoseido 200 ppi ekisho display series

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    In mobile equipment, in demand is a high precision liquid crystal display (LCD) having the power of expression equivalent to printed materials like magazines because of the necessity of displaying a large amount of information on a easily potable small screen. In addition, with the spread and high-quality image of digital still cameras, it is strongly desired to display photographed digital image data in high quality. Toshiba Corp., by low temperature polysilicone (p-Si) technology, commercialized the liquid crystal display series of 200 ppi (pixels per inch) precision dealing with the rise of the high-precision high-image quality LCD market. The super high precision of 200 ppi enables the display of smooth beautiful animation comparable to printed sheets of magazines and photographs. The display series are suitable for the display of various information services such as electronic books and electronic photo-viewers including internet. The screen sizes lined up are No. 4 type VGA (640x480 pixels) of a small pocket notebook size and No. 6.3 type XGA (1,024x768 pixels) of a paperback size, with a larger screen to be furthered. (translated by NEDO)

  13. A Compressive Superresolution Display

    KAUST Repository

    Heide, Felix; Gregson, James; Wetzstein, Gordon; Raskar, Ramesh; Heidrich, Wolfgang

    2014-01-01

    In this paper, we introduce a new compressive display architecture for superresolution image presentation that exploits co-design of the optical device configuration and compressive computation. Our display allows for superresolution, HDR, or glasses-free 3D presentation.

  14. A Compressive Superresolution Display

    KAUST Repository

    Heide, Felix

    2014-06-22

    In this paper, we introduce a new compressive display architecture for superresolution image presentation that exploits co-design of the optical device configuration and compressive computation. Our display allows for superresolution, HDR, or glasses-free 3D presentation.

  15. Higher order corrections to energy levels of muonic atoms

    International Nuclear Information System (INIS)

    Rinker, G.A. Jr.; Steffen, R.M.

    1975-08-01

    In order to facilitate the analysis of muonic x-ray spectra, the results of numerical computations of all higher order quantum electrodynamical corrections to the energy levels of muonic atoms are presented in tabular and graphical form. These corrections include the vacuum polarization corrections caused by emission and reabsorption of virtual electron pairs to all orders, including ''double-bubble'' and ''cracked-egg'' diagrams. An estimate of the Delbruecke scattering-type correction is presented. The Lamb-shift (second- and fourth-order vertex) corrections have been calculated including the correction for the anomalous magnetic moment of the muon. The relativistic nuclear motion (or recoil) correction as well as the correction caused by the screening of the atomic electrons is presented in graphs. For the sake of completeness a graph of the nuclear polarization as computed on the basis of Chen's approach has been included. All calculations were made with a two-parameter Fermi distribution of the nuclear charge density. 7 figures, 23 references

  16. Pressure pain threshold and β-endorphins plasma level are higher in lean polycystic ovary syndrome women.

    Science.gov (United States)

    Kiałka, Marta; Milewicz, Tomasz; Mrozińska, Sandra; Rogatko, Iwona; Sztefko, Krystyna; Majewska, Renata

    2017-12-01

    Despite some evidence that indicates that the evolution of polycystic ovary syndrome (PCOS) is related to the activity of the endogenous opioid system, and that concentration of plasma β-endorphin levels can increase pain threshold, there are no studies which evaluate pressure pain threshold in the PCOS women population. In 48 lean women with PCOS and 38 lean women without this disorder plasma β-endorphins and PPT were measured. The β-endorphins level was higher in the PCOS group compared to the controls (15.28±2.49 pg/mL vs. 6.33±1.71 pg/mL, PPCOS group PPTs measured on deltoid and trapezius muscles were higher compared to the controls (9.33±1.3 kg/cm² vs. 5.19±0.57 kg/cm², PPCOS group. Increase in β-endorphin level of 1 pg/mL was associated with increase of PPT value on deltoid muscle of 0.23 kg/cm² (R=0.632, P=0.011) and of 0.18 kg/cm² on trapezius muscle (R=0.588, P=0.037). There were no correlations between testosterone level and PPT in PCOS group. β-endorphin serum level as well as PPT are higher in lean PCOS group than in controls. We found correlations between β-endorphin levels and PPT in the PCOS group. It may suggest the role of endogenous opioids in the pathogenesis of PCOS and also that the increases in circulating plasma β-endorphins concentration can increases PPT in this group.

  17. JTEC panel on display technologies in Japan

    Science.gov (United States)

    Tannas, Lawrence E., Jr.; Glenn, William E.; Credelle, Thomas; Doane, J. William; Firester, Arthur H.; Thompson, Malcolm

    1992-01-01

    This report is one in a series of reports that describes research and development efforts in Japan in the area of display technologies. The following are included in this report: flat panel displays (technical findings, liquid crystal display development and production, large flat panel displays (FPD's), electroluminescent displays and plasma panels, infrastructure in Japan's FPD industry, market and projected sales, and new a-Si active matrix liquid crystal display (AMLCD) factory); materials for flat panel displays (liquid crystal materials, and light-emissive display materials); manufacturing and infrastructure of active matrix liquid crystal displays (manufacturing logistics and equipment); passive matrix liquid crystal displays (LCD basics, twisted nematics LCD's, supertwisted nematic LCD's, ferroelectric LCD's, and a comparison of passive matrix LCD technology); active matrix technology (basic active matrix technology, investment environment, amorphous silicon, polysilicon, and commercial products and prototypes); and projection displays (comparison of Japanese and U.S. display research, and technical evaluation of work).

  18. Wavy Architecture Thin-Film Transistor for Ultrahigh Resolution Flexible Displays

    KAUST Repository

    Hanna, Amir Nabil; Kutbee, Arwa Talal; Subedi, Ram Chandra; Ooi, Boon S.; Hussain, Muhammad Mustafa

    2017-01-01

    A novel wavy-shaped thin-film-transistor (TFT) architecture, capable of achieving 70% higher drive current per unit chip area when compared with planar conventional TFT architectures, is reported for flexible display application. The transistor, due to its atypical architecture, does not alter the turn-on voltage or the OFF current values, leading to higher performance without compromising static power consumption. The concept behind this architecture is expanding the transistor's width vertically through grooved trenches in a structural layer deposited on a flexible substrate. Operation of zinc oxide (ZnO)-based TFTs is shown down to a bending radius of 5 mm with no degradation in the electrical performance or cracks in the gate stack. Finally, flexible low-power LEDs driven by the respective currents of the novel wavy, and conventional coplanar architectures are demonstrated, where the novel architecture is able to drive the LED at 2 × the output power, 3 versus 1.5 mW, which demonstrates the potential use for ultrahigh resolution displays in an area efficient manner.

  19. Wavy Architecture Thin-Film Transistor for Ultrahigh Resolution Flexible Displays

    KAUST Repository

    Hanna, Amir Nabil

    2017-11-13

    A novel wavy-shaped thin-film-transistor (TFT) architecture, capable of achieving 70% higher drive current per unit chip area when compared with planar conventional TFT architectures, is reported for flexible display application. The transistor, due to its atypical architecture, does not alter the turn-on voltage or the OFF current values, leading to higher performance without compromising static power consumption. The concept behind this architecture is expanding the transistor\\'s width vertically through grooved trenches in a structural layer deposited on a flexible substrate. Operation of zinc oxide (ZnO)-based TFTs is shown down to a bending radius of 5 mm with no degradation in the electrical performance or cracks in the gate stack. Finally, flexible low-power LEDs driven by the respective currents of the novel wavy, and conventional coplanar architectures are demonstrated, where the novel architecture is able to drive the LED at 2 × the output power, 3 versus 1.5 mW, which demonstrates the potential use for ultrahigh resolution displays in an area efficient manner.

  20. Australian Children's Understanding of Display Rules

    Science.gov (United States)

    Choy, Grace

    2009-01-01

    Cultural display rules govern the manifestation of emotional expressions. In compliance with display rules, the facial expressions displayed (i.e. apparent emotion) may be incongruent with the emotion experienced (i.e. real emotion). This study investigates Australian Caucasian children's understanding of display rules. A sample of 80 four year…

  1. The case for transparent depth display

    NARCIS (Netherlands)

    Kooi, F.L.

    2003-01-01

    Purpose: The continuing developments in display technology have resulted in the ability to present increasing amounts of data on computer displays. One of the coming break-throughs is generally believed to be the introduction of '3-D displays': displays with a true sense of depth. Though these types

  2. : Light Steering Projection Systems and Attributes for HDR Displays

    KAUST Repository

    Damberg, Gerwin

    2017-06-02

    New light steering projectors in cinema form images by moving light away from dark regions into bright areas of an image. In these systems, the peak luminance of small features can far exceed full screen white luminance. In traditional projectors where light is filtered or blocked in order to give shades of gray (or colors), the peak luminance is fixed. The luminance of chromatic features benefit in the same way as white features, and chromatic image details can be reproduced at high brightness leading to a much wider overall color gamut coverage than previously possible. Projectors of this capability are desired by the creative community to aid in and enhance storytelling. Furthermore, reduced light source power requirements of light steering projectors provide additional economic and environmental benefits. While the dependency of peak luminance level on (bright) image feature size is new in the digital cinema space, display technologies with identical characteristics such as OLED, LED LCD and Plasma TVs are well established in the home. Similarly, direct view LED walls are popular in events, advertising and architectural markets. To enable consistent color reproduction across devices in today’s content production pipelines, models that describe modern projectors and display attributes need to evolve together with HDR standards and available metadata. This paper is a first step towards rethinking legacy display descriptors such as contrast, peak luminance and color primaries in light of new display technology. We first summarize recent progress in the field of light steering projectors in cinema and then, based on new projector and existing display characteristics propose the inclusion of two simple display attributes: Maximum Average Luminance and Peak (Color) Primary Luminance. We show that the proposed attributes allow a better prediction of content reproducibility on HDR displays. To validate this assertion, we test professional content on a commercial HDR

  3. CLS to higher education administrator: the right navigational skills.

    Science.gov (United States)

    Campbell, Suzanne; LaCost, Barbara Y

    2010-01-01

    To identify the experiences, training, and opportunities that directed and influenced the career paths of women clinical laboratory scientists that transitioned to higher education administrators. A multi-site case study design was selected for this qualitative research involving a purposive sample of eight research participants. Data collection was guided by ten open-ended questions in seven face-to-face and one telephone semi-formal interviews. The purposive sample included women clinical laboratory scientists who held a current higher education administrative position at the dean's level, including associate and assistant dean positions, in a university setting. The participants were located in eight higher education institutions in Nebraska, Illinois, Ohio, Tennessee, Missouri, and Texas. MAIN Leadership skills/characteristics, professional development opportunities, mentoring experiences, opportunities for advancement. Possessing a doctoral degree, demonstrating competence and strong leadership skills, having a good role model and/or mentor, displaying the ability to see the big picture, and possessing exemplary communication skills were identified by this group of women as necessary requirements for obtaining and maintaining a position as a higher education administrator. The participants in this study confirmed that by possessing a terminal degree and a defined skill set, they were able to obtain a higher education administrator position.

  4. The Relationship between Multiplication Fact Speed-Recall and Fluency and Higher Level Mathematics Learning with Eighth Grade Middle School Students

    Science.gov (United States)

    Curry, Steven James

    2012-01-01

    This quantitative study investigated relationships between higher level mathematics learning and multiplication fact fluency, multiplication fact speed-recall, and reading grade equivalency of eighth grade students in Algebra I and Pre-Algebra. Higher level mathematics learning was indicated by an average score of 80% or higher on first and second…

  5. Bibliographic Displays in OPACs and Web Catalogs: How Well Do They Comply with Display Guidelines?

    Science.gov (United States)

    Cherry, Joan M.

    1998-01-01

    Evaluation of data from assessments of full bibliographic displays in academic library OPACs (online public access catalogs) and World Wide Web catalogs against a checklist of desirable features found that OPAC displays scored 58% and Web displays scored 60%. Discusses weaknesses, focusing on those found in the majority of the displays…

  6. Comparative Analysis of Conventional Electronic and OZ Concept Displays for Aircraft Energy Management

    Science.gov (United States)

    Baker, Erik Reese

    A repeated-measures, within-subjects design was conducted on 58 participant pilots to assess mean differences on energy management situation awareness response time and response accuracy between a conventional electronic aircraft display, a primary flight display (PFD), and an ecological interface design aircraft display, the OZ concept display. Participants were associated with a small Midwestern aviation university, including student pilots, flight instructors, and faculty with piloting experience. Testing consisted of observing 15 static screenshots of each cockpit display type and then selecting applicable responses from 27 standardized responses for each screen. A paired samples t-test was computed comparing accuracy and response time for the two displays. There was no significant difference in means between PFD Response Time and OZ Response Time. On average, mean PFD Accuracy was significantly higher than mean OZ Accuracy (MDiff = 13.17, SDDiff = 20.96), t(57) = 4.78, p performance differences were not operationally remarkable. There was no significant correlation between PFD Response Time and PFD Accuracy, but there was a significant correlation between OZ Response Time and OZ Accuracy, r (58) = .353, p performing as well as experienced professional pilots on dynamic flight tasks with the OZ display. A demographic questionnaire and a feedback survey were included in the trial. An equivalent three-quarters majority of participants rated the PFD as "easy" and the OZ as "confusing", yet performance accuracy and response times between the two displays were not operationally different.

  7. Reconfigurable Full-Page Braille Displays

    Science.gov (United States)

    Garner, H. Douglas

    1994-01-01

    Electrically actuated braille display cells of proposed type arrayed together to form full-page braille displays. Like other braille display cells, these provide changeable patterns of bumps driven by digitally recorded text stored on magnetic tapes or in solid-state electronic memories. Proposed cells contain electrorheological fluid. Viscosity of such fluid increases in strong electrostatic field.

  8. Diagnostic accuracy of different display types in detection of recurrent caries under restorations by using CBCT.

    Science.gov (United States)

    Baltacıoĝlu, İsmail H; Eren, Hakan; Yavuz, Yasemin; Kamburoğlu, Kıvanç

    To assess the in vitro diagnostic ability of CBCT images using seven different display types in the detection of recurrent caries. Our study comprised 128 extracted human premolar and molar teeth. 8 groups each containing 16 teeth were obtained as follows: (1) Black Class I (Occlusal) amalgam filling without caries; (2) Black Class I (Occlusal) composite filling without caries; (3) Black Class II (Proximal) amalgam filling without caries; (4) Black Class II (Proximal) composite filling without caries; (5) Black Class I (Occlusal) amalgam filling with caries; (6) Black Class I (Occlusal) composite filling with caries; (7) Black Class II (Proximal) amalgam filling with caries; and (8) Black Class II (Proximal) composite filling with caries. Teeth were imaged using 100 × 90 mm field of view at three different voxel sizes of a CBCT unit (Planmeca ProMax(®) 3D ProFace™; Planmeca, Helsinki, Finland). CBCT TIFF images were opened and viewed using custom-designed software for computers on different display types. Intra- and interobserver agreements were calculated. The highest area under the receiver operating characteristic curve (Az) values for each image type, observer, reading and restoration were compared using z-tests against Az = 0.5. The significance level was set at p = 0.05. We found poor and moderate agreements. In general, Az values were found when software and medical diagnostic monitor were utilized. For Observer 2, Az values were statistically significantly higher when software was used on medical monitor [p = 0.036, p = 0.015 and p = 0.002, for normal-resolution mode (0.200 mm(3) voxel size), high-resolution mode (0.150 mm(3) voxel size) and low-resolution mode (0.400 mm(3) voxel size), respectively]. No statistically significant differences were found among other display types for all modes (p > 0.05). In general, no difference was found among 3 different voxel sizes (p > 0.05). In general, higher Az values were

  9. Diagnostic accuracy of different display types in detection of recurrent caries under restorations by using CBCT

    Science.gov (United States)

    Baltacıoĝlu, İsmail H; Eren, Hakan; Yavuz, Yasemin

    2016-01-01

    Objectives: To assess the in vitro diagnostic ability of CBCT images using seven different display types in the detection of recurrent caries. Methods: Our study comprised 128 extracted human premolar and molar teeth. 8 groups each containing 16 teeth were obtained as follows: (1) Black Class I (Occlusal) amalgam filling without caries; (2) Black Class I (Occlusal) composite filling without caries; (3) Black Class II (Proximal) amalgam filling without caries; (4) Black Class II (Proximal) composite filling without caries; (5) Black Class I (Occlusal) amalgam filling with caries; (6) Black Class I (Occlusal) composite filling with caries; (7) Black Class II (Proximal) amalgam filling with caries; and (8) Black Class II (Proximal) composite filling with caries. Teeth were imaged using 100 × 90 mm field of view at three different voxel sizes of a CBCT unit (Planmeca ProMax® 3D ProFace™; Planmeca, Helsinki, Finland). CBCT TIFF images were opened and viewed using custom-designed software for computers on different display types. Intra- and interobserver agreements were calculated. The highest area under the receiver operating characteristic curve (Az) values for each image type, observer, reading and restoration were compared using z-tests against Az = 0.5. The significance level was set at p = 0.05. Results: We found poor and moderate agreements. In general, Az values were found when software and medical diagnostic monitor were utilized. For Observer 2, Az values were statistically significantly higher when software was used on medical monitor [p = 0.036, p = 0.015 and p = 0.002, for normal-resolution mode (0.200 mm3 voxel size), high-resolution mode (0.150 mm3 voxel size) and low-resolution mode (0.400 mm3 voxel size), respectively]. No statistically significant differences were found among other display types for all modes (p > 0.05). In general, no difference was found among 3 different voxel sizes (p > 0.05). In general

  10. Statistical analysis and data display an intermediate course with examples in R

    CERN Document Server

    Heiberger, Richard M

    2015-01-01

    This contemporary presentation of statistical methods features extensive use of graphical displays for exploring data and for displaying the analysis. The authors demonstrate how to analyze data—showing code, graphics, and accompanying tabular listings—for all the methods they cover. They emphasize how to construct and interpret graphs. They discuss principles of graphical design. They identify situations where visual impressions from graphs may need confirmation from traditional tabular results. All chapters have exercises. The authors provide and discuss R functions for all the new graphical display formats. All graphs and tabular output in the book were constructed using these functions. Complete R scripts for all examples and figures are provided for readers to use as models for their own analyses. This book can serve as a standalone text for statistics majors at the master’s level and for other quantitatively oriented disciplines at the doctoral level, and as a reference book for researchers. In-de...

  11. Toward raising the higher level of radiological nursing

    International Nuclear Information System (INIS)

    Kusama, Tomoko; Ban, Nobuhiko; Ono, Koji

    2013-01-01

    The role and purpose of nursing in the radiological field are discussed with essentials of radiological nursing for raising its higher level and needed fundamental education. The discussion is from the thought that, at Fukushima Nuclear Power Plant Accident (Mar. 2011), general medical staff including nurses are rather insufficient of radiological knowledge like the exposure, radiation effect and risk. In the medical radiological field, nurses are expected to play roles of arranging the circumstance for patient's ease like explanation about health effect/risk, appropriate nursing of them after radiological diagnosis, radiation protection of nurses themselves, and of environment. At such an emergency as the Accident, care for the acutely exposed victims, their decontamination and responding to patient's concern are necessary. At the later phase, also needed are nursing of victims undergoing health management done by authorities and of radiological workers concerned as well as the third item above. Therefore, fundamentals of radiological knowledge such as physics, exposure, health effects, protection, contamination, legal rules and risk communication are required in the education of nurses. Otherwise, this education can be conducted as a part of safety security and physical assessment. The Accident also gives us the importance of radiological risk communication with its victims. (T.T.)

  12. Effect of the Oculus Rift head mounted display on postural stability

    DEFF Research Database (Denmark)

    Epure, Paula; Gheorghe, Cristina; Nissen, Thomas

    2014-01-01

    board controlling a skiing game. Two tests were conducted: full-vision versus blindfolded and HMD versus monitor display. Results were that five of the six balance-impaired adults and six of the eight non-balance-impaired adults showed higher degree of postural stability while using a monitor display......This study explored how a HMD-experienced virtual environment influences physical balance of six balance-impaired adults 59-69 years-of-age, when compared to a control group of eight non-balance-impaired adults, 18-28 years-of-age. The setup included a Microsoft Kinect and a self-created balance....... Conclusions are that HMD, used in this context, leads to postural instability....

  13. Display-management system for MFTF

    International Nuclear Information System (INIS)

    Nelson, D.O.

    1981-01-01

    The Mirror Fusion Test Facility (MFTF) is controlled by 65 local control microcomputers which are supervised by a local network of nine 32-bit minicomputers. Associated with seven of the nine computers are state-of-the-art graphics devices, each with extensive local processing capability. These devices provide the means for an operator to interact with the control software running on the minicomputers. It is critical that the information the operator views accurately reflects the current state of the experiment. This information is integrated into dynamically changing pictures called displays. The primary organizational component of the display system is the software-addressable segment. The segments created by the display creation software are managed by display managers associated with each graphics device. Each display manager uses sophisticated storage management mechanisms to keep the proper segments resident in the local graphics device storage

  14. Data display with the Q system

    International Nuclear Information System (INIS)

    Oothoudt, M.A.

    1979-01-01

    The Q data-acquisition system for PDP-11 mini-computers at the Clinton P. Anderson Meson Physics Facility (LAMPF) provides experimenters with basic tools for on-line data display. Tasks are available to plot one- and two-parameter histograms on Tektronix 4000 series storage-tube terminals. The histograms to be displayed and the display format may be selected with simple keyboard commands. A task is also available to create and display live two-parameter scatter plots for any acquired or calculated quantities. Other tasks in the system manage the display data base, list display parameters and histogram contents on hardcopy devices, and save core histograms on disk or tape for off-line analysis. 8 figures

  15. Silenced rice in both cytosolic ascorbate peroxidases displays pre-acclimation to cope with oxidative stress induced by 3-aminotriazole-inhibited catalase.

    Science.gov (United States)

    Bonifacio, Aurenivia; Carvalho, Fabrício E L; Martins, Marcio O; Lima Neto, Milton C; Cunha, Juliana R; Ribeiro, Carolina W; Margis-Pinheiro, Marcia; Silveira, Joaquim A G

    2016-08-20

    The maintenance of H2O2 homeostasis and signaling mechanisms in plant subcellular compartments is greatly dependent on cytosolic ascorbate peroxidases (APX1 and APX2) and peroxisomal catalase (CAT) activities. APX1/2 knockdown plants were utilized in this study to clarify the role of increased cytosolic H2O2 levels as a signal to trigger the antioxidant defense system against oxidative stress generated in peroxisomes after 3-aminotriazole-inhibited catalase (CAT). Before supplying 3-AT, silenced APX1/2 plants showed marked changes in their oxidative and antioxidant profiles in comparison to NT plants. After supplying 3-AT, APX1/2 plants triggered up-expression of genes belonging to APX (OsAPX7 and OsAPX8) and GPX families (OsGPX1, OsGPX2, OsGPX3 and OsGPX5), but to a lower extent than in NT plants. In addition, APX1/2 exhibited lower glycolate oxidase (GO) activity, higher CO2 assimilation, higher cellular integrity and higher oxidation of GSH, whereas the H2O2 and lipid peroxidation levels remained unchanged. This evidence indicates that redox pre-acclimation displayed by silenced rice contributed to coping with oxidative stress generated by 3-AT. We suggest that APX1/2 plants were able to trigger alternative oxidative and antioxidant mechanisms involving signaling by H2O2, allowing these plants to display effective physiological responses for protection against oxidative damage generated by 3-AT, compared to non-transformed plants. Copyright © 2016 Elsevier GmbH. All rights reserved.

  16. Conceptual Design of Industrial Process Displays

    DEFF Research Database (Denmark)

    Pedersen, C.R.; Lind, Morten

    1999-01-01

    discusses aspects of process display design taking into account both the designer's and the operator's points of view. Three aspects are emphasized: the operator tasks, the display content and the display form. The distinction between these three aspects is the basis for proposing an outline for a display......Today, process displays used in industry are often designed on the basis of piping and instrumentation diagrams without any method of ensuring that the needs of the operators are fulfilled. Therefore, a method for a systematic approach to the design of process displays is needed. This paper...... by a simple example from a plant with batch processes. Later the method is applied to develop a supervisory display for a condenser system in a nuclear power plant. The differences between the continuous plant domain of power production and the batch processes from the example are analysed and broad...

  17. Renin-angiotensin-aldosterone system inhibitors lower hemoglobin and hematocrit only in renal transplant recipients with initially higher levels.

    Science.gov (United States)

    Mikolasevic, I; Zaputovic, L; Zibar, L; Begic, I; Zutelija, M; Klanac, A; Majurec, I; Simundic, T; Minazek, M; Orlic, L

    2016-04-01

    We have analyzed the effects of renin-angiotensin-aldosterone system (RAAS) inhibitors on evolution of hemoglobin (Hb) and hematocrit (Htc) levels as well as on the evaluation of kidney graft function in stable renal transplant recipients (RTRs) in respect with initially higher or lower Hb and Htc values. The study group comprised of 270 RTRs with stable graft function. Besides other prescribed antihypertensive therapy, 169 of them have been taking RAAS inhibitors. We wanted to analyze the effect of the use of RAAS inhibitors on Hb and Htc in patients with initially higher or lower Hb/Htc values. For this analysis, only RTRs that were taking RAAS inhibitors were stratified into two groups: one with higher Hb and Htc (initial Hb≥150g/L and Htc≥45%) and another one with lower Hb and Htc (initial Hb<150g/L and Htc<45%) values. Thirty-four RTRs with initially higher Hb and 41 RTRs with initially higher Htc had a statistically significant decrease in Hb (p=0.006) and Htc (p<0.0001) levels after 12-months of follow-up. In the group of patients with initially lower Hb (135 RTRs) and Htc (128 RTRs) there was a significant increase in Hb (p=0.0001) and Htc (p=0.004) levels through the observed period. The use of RAAS inhibitors has been associated with a trend of slowing renal insufficiency in RTRs (p=0.03). RAAS inhibitors lower Hb and Htc only in RTRs with initially higher levels. In patients with initially lower Hb and Htc levels, the use of these drugs is followed by beneficial impact on erythropoiesis and kidney graft function. Copyright © 2015 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  18. A universal and smart helmet-mounted display of large FOV

    Science.gov (United States)

    Zhang, Nan; Weng, Dongdong; Wang, Yongtian; Li, Xuan; Liu, Youhai

    2011-11-01

    HMD (head-mounted display) is an important virtual reality device, which has played a vital role in VR application system. Compared with traditional HMD which cannot be applied in the daily life owing to their disadvantage on the price and performance, a new universal and smart Helmet-Mounted Display of large FOV uses excellent performance and widespread popularity as its starting point. By adopting simplified visual system and transflective system that combines the transmission-type and reflection-type display system with transflective glass based on the Huggens-Fresnel principle, we have designed a HMD with wide field of view, which can be easy to promote and popularize. Its resolution is 800*600, and field of view is 36.87°(vertical)* 47.92°(horizontal). Its weight is only 1080g. It has caught up with the advanced world levels.

  19. Higher cortisol levels at diurnal trough predict greater attentional bias towards threat in healthy young adults.

    Science.gov (United States)

    Hakamata, Yuko; Izawa, Shuhei; Sato, Eisuke; Komi, Shotaro; Murayama, Norio; Moriguchi, Yoshiya; Hanakawa, Takashi; Inoue, Yusuke; Tagaya, Hirokuni

    2013-11-01

    Attentional bias (AB), selective information processing towards threat, can exacerbate anxiety and depression. Despite growing interest, physiological determinants of AB are yet to be understood. We examined whether stress hormone cortisol and its diurnal variation pattern contribute to AB. Eighty-seven healthy young adults underwent assessments for AB, anxious personality traits, depressive symptoms, and attentional function. Salivary cortisol was collected at three time points daily (at awakening, 30 min after awakening, and bedtime) for 2 consecutive days. We performed: (1) multiple regression analysis to examine the relationships between AB and the other measures and (2) analysis of variance (ANOVA) between groups with different cortisol variation patterns for the other measures. Multiple regression analysis revealed that higher cortisol levels at bedtime (pattention and cortisol measurement at three time points daily. We showed that higher cortisol levels at bedtime and blunted cortisol variation are associated with greater AB. Individuals who have higher cortisol levels at diurnal trough might be at risk of clinical anxiety or depression but could also derive more benefits from the attentional-bias-modification program. © 2013 Elsevier B.V. All rights reserved.

  20. Helmet-Mounted Display Design Guide

    Science.gov (United States)

    1997-11-03

    on openStack create menu "CSHMD" set the menuitems of "CSHMD" to "(Main Menu; References;-; Definitions;Display Criteria;Display Formats;Display Modes...34Macintosh" then put ":" into dirSep else put "V’ into dirSep put stackPathO&"Resource"&dirSep into gResPath put 0 into gXRef end openStack on

  1. Phase transitions between lower and higher level management learning in times of crisis: an experimental study based on synergetics.

    Science.gov (United States)

    Liening, Andreas; Strunk, Guido; Mittelstadt, Ewald

    2013-10-01

    Much has been written about the differences between single- and double-loop learning, or more general between lower level and higher level learning. Especially in times of a fundamental crisis, a transition between lower and higher level learning would be an appropriate reaction to a challenge coming entirely out of the dark. However, so far there is no quantitative method to monitor such a transition. Therefore we introduce theory and methods of synergetics and present results from an experimental study based on the simulation of a crisis within a business simulation game. Hypothesized critical fluctuations - as a marker for so-called phase transitions - have been assessed with permutation entropy. Results show evidence for a phase transition during the crisis, which can be interpreted as a transition between lower and higher level learning.

  2. Ruggedized Full-Color Flexible OLED Display

    National Research Council Canada - National Science Library

    Hack, Michael

    2003-01-01

    .... The team comprised Universal Display Corporation, Princeton University, the University of Southern California, Penn State University, L3 Displays and Vitex Systems, and was led by Universal Display Corporation (PI: Michael Hack...

  3. Do higher levels of education and skills in an area benefit wider society?

    OpenAIRE

    Winters, John V.

    2015-01-01

    Formal schooling increases earnings and provides other individual benefits. However, societal benefits of education may exceed individual benefits. Research finds that increased average education levels in an area are correlated with higher earnings, even for locals with relatively little education. Science, technology, engineering, and mathematics (STEM) graduates appear to have especially strong external effects, due to their role in stimulating innovation and economic growth. Several strat...

  4. Support for a ban on tobacco powerwalls and other point-of-sale displays: findings from focus groups.

    Science.gov (United States)

    Schmitt, Carol L; Allen, Jane A; Kosa, Katherine M; Curry, Laurel E

    2015-02-01

    This study uses focus group data to document consumer perceptions of powerwall and other point-of-sale (POS) tobacco displays, and support for a ban on tobacco displays. Four focus groups were conducted in 2012 by a trained moderator. The study comprised 34 adult residents of New York State, approximately half with children under age 18 years living at home. Measures used in the study were awareness and perceptions of powerwall and other POS displays, and level of support for a ban on tobacco displays. Analysis focused on perceptions of powerwall and other POS displays, level of support for a ban on tobacco displays and reasons participants oppose a display ban. This study documents a general lack of concern about tobacco use in the community, which does not appear to be associated with support for a ban on POS tobacco displays. Although all participants had seen tobacco powerwalls and most considered them to be a form of advertising, participants were divided as to whether they played a role in youth smoking. Additional research is warranted to determine what factors individuals weigh in assigning value to a ban on POS tobacco displays and other tobacco control policies and how educational efforts can influence those assessments. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  5. Biatriosporin D displays anti-virulence activity through decreasing the intracellular cAMP levels

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ming; Chang, Wenqiang; Shi, Hongzhuo; Zhou, Yanhui; Zheng, Sha; Li, Ying; Li, Lin; Lou, Hongxiang, E-mail: louhongxiang@sdu.edu.cn

    2017-05-01

    Candidiasis has long been a serious human health problem, and novel antifungal approaches are greatly needed. During both superficial and systemic infection, C. albicans relies on a battery of virulence factors, such as adherence, filamentation, and biofilm formation. In this study, we found that a small phenolic compound, Biatriosporin D (BD), isolated from an endolichenic fungus, Biatriospora sp., displayed anti-virulence activity by inhibiting adhesion, hyphal morphogenesis and biofilm formation of C. albicans. Of note is the high efficacy of BD in preventing filamentation with a much lower dose than its MIC value. Furthermore, BD prolonged the survival of worms infected by C. albicans in vivo. Quantitative real-time PCR analysis, exogenous cAMP rescue experiments and intracellular cAMP measurements revealed that BD regulates the Ras1-cAMP-Efg1 pathway by reducing cAMP levels to inhibit the hyphal formation. Further investigation showed that BD could upregulate Dpp3 to synthesize much more farnesol, which could inhibit the activity of Cdc35 and reduce the generation of cAMP. Taken together, these findings indicate that BD stimulates the expression of Dpp3 to synthesize more farnesol that directly inhibits the Cdc35 activity, reducing intracellular cAMP and thereby disrupting the morphologic transition and attenuating the virulence of C. albicans. Our study uncovers the underlying mechanism of BD as a prodrug in fighting against pathogenic C. albicans and provides a potential application of BD in fighting clinically relevant fungal infections by targeting fungal virulence. - Highlights: • BD inhibits the filamentation of C. albicans in multiple hypha-inducing conditions. • BD can prolong the survival of nematodes infected by C. albicans. • BD stimulates the expression of Dpp3 to synthesize more farnesol. • BD reduces intracellular cAMP and regulates Ras1-cAMP-PKA pathway.

  6. Biatriosporin D displays anti-virulence activity through decreasing the intracellular cAMP levels

    International Nuclear Information System (INIS)

    Zhang, Ming; Chang, Wenqiang; Shi, Hongzhuo; Zhou, Yanhui; Zheng, Sha; Li, Ying; Li, Lin; Lou, Hongxiang

    2017-01-01

    Candidiasis has long been a serious human health problem, and novel antifungal approaches are greatly needed. During both superficial and systemic infection, C. albicans relies on a battery of virulence factors, such as adherence, filamentation, and biofilm formation. In this study, we found that a small phenolic compound, Biatriosporin D (BD), isolated from an endolichenic fungus, Biatriospora sp., displayed anti-virulence activity by inhibiting adhesion, hyphal morphogenesis and biofilm formation of C. albicans. Of note is the high efficacy of BD in preventing filamentation with a much lower dose than its MIC value. Furthermore, BD prolonged the survival of worms infected by C. albicans in vivo. Quantitative real-time PCR analysis, exogenous cAMP rescue experiments and intracellular cAMP measurements revealed that BD regulates the Ras1-cAMP-Efg1 pathway by reducing cAMP levels to inhibit the hyphal formation. Further investigation showed that BD could upregulate Dpp3 to synthesize much more farnesol, which could inhibit the activity of Cdc35 and reduce the generation of cAMP. Taken together, these findings indicate that BD stimulates the expression of Dpp3 to synthesize more farnesol that directly inhibits the Cdc35 activity, reducing intracellular cAMP and thereby disrupting the morphologic transition and attenuating the virulence of C. albicans. Our study uncovers the underlying mechanism of BD as a prodrug in fighting against pathogenic C. albicans and provides a potential application of BD in fighting clinically relevant fungal infections by targeting fungal virulence. - Highlights: • BD inhibits the filamentation of C. albicans in multiple hypha-inducing conditions. • BD can prolong the survival of nematodes infected by C. albicans. • BD stimulates the expression of Dpp3 to synthesize more farnesol. • BD reduces intracellular cAMP and regulates Ras1-cAMP-PKA pathway.

  7. A variable-collimation display system

    Science.gov (United States)

    Batchko, Robert; Robinson, Sam; Schmidt, Jack; Graniela, Benito

    2014-03-01

    Two important human depth cues are accommodation and vergence. Normally, the eyes accommodate and converge or diverge in tandem; changes in viewing distance cause the eyes to simultaneously adjust both focus and orientation. However, ambiguity between accommodation and vergence cues is a well-known limitation in many stereoscopic display technologies. This limitation also arises in state-of-the-art full-flight simulator displays. In current full-flight simulators, the out-the-window (OTW) display (i.e., the front cockpit window display) employs a fixed collimated display technology which allows the pilot and copilot to perceive the OTW training scene without angular errors or distortions; however, accommodation and vergence cues are limited to fixed ranges (e.g., ~ 20 m). While this approach works well for long-range, the ambiguity of depth cues at shorter range hinders the pilot's ability to gauge distances in critical maneuvers such as vertical take-off and landing (VTOL). This is the first in a series of papers on a novel, variable-collimation display (VCD) technology that is being developed under NAVY SBIR Topic N121-041 funding. The proposed VCD will integrate with rotary-wing and vertical take-off and landing simulators and provide accurate accommodation and vergence cues for distances ranging from approximately 3 m outside the chin window to ~ 20 m. A display that offers dynamic accommodation and vergence could improve pilot safety and training, and impact other applications presently limited by lack of these depth cues.

  8. Liquid crystal true 3D displays for augmented reality applications

    Science.gov (United States)

    Li, Yan; Liu, Shuxin; Zhou, Pengcheng; Chen, Quanming; Su, Yikai

    2018-02-01

    Augmented reality (AR) technology, which integrates virtual computer-generated information into the real world scene, is believed to be the next-generation human-machine interface. However, most AR products adopt stereoscopic 3D display technique, which causes the accommodation-vergence conflict. To solve this problem, we have proposed two approaches. The first is a multi-planar volumetric display using fast switching polymer-stabilized liquid crystal (PSLC) films. By rapidly switching the films between scattering and transparent states while synchronizing with a high-speed projector, the 2D slices of a 3D volume could be displayed in time sequence. We delved into the research on developing high-performance PSLC films in both normal mode and reverse mode; moreover, we also realized the demonstration of four-depth AR images with correct accommodation cues. For the second approach, we realized a holographic AR display using digital blazed gratings and a 4f system to eliminate zero-order and higher-order noise. With a 4k liquid crystal on silicon device, we achieved a field of view (FOV) of 32 deg. Moreover, we designed a compact waveguidebased holographic 3D display. In the design, there are two holographic optical elements (HOEs), each of which functions as a diffractive grating and a Fresnel lens. Because of the grating effect, holographic 3D image light is coupled into and decoupled out of the waveguide by modifying incident angles. Because of the lens effect, the collimated zero order light is focused at a point, and got filtered out. The optical power of the second HOE also helps enlarge FOV.

  9. Combat vehicle crew helmet-mounted display: next generation high-resolution head-mounted display

    Science.gov (United States)

    Nelson, Scott A.

    1994-06-01

    The Combat Vehicle Crew Head-Mounted Display (CVC HMD) program is an ARPA-funded, US Army Natick Research, Development, and Engineering Center monitored effort to develop a high resolution, flat panel HMD for the M1 A2 Abrams main battle tank. CVC HMD is part of the ARPA High Definition Systems (HDS) thrust to develop and integrate small (24 micrometers square pels), high resolution (1280 X 1024 X 6-bit grey scale at 60 frame/sec) active matrix electroluminescent (AMEL) and active matrix liquid crystal displays (AMLCD) for head mounted and projection applications. The Honeywell designed CVC HMD is a next generation head-mounted display system that includes advanced flat panel image sources, advanced digital display driver electronics, high speed (> 1 Gbps) digital interconnect electronics, and light weight, high performance optical and mechanical designs. The resulting dramatic improvements in size, weight, power, and cost have already led to program spin offs for both military and commercial applications.

  10. Deafness and motor abilities level

    Directory of Open Access Journals (Sweden)

    A Zwierzchowska

    2008-09-01

    Full Text Available The audition injury hinders some motor motions and the organised coordination at the higher level and may be a cause of disturbances and disorder in some motor abilities adoption. It was assumed that deafness including its aetiology and injury mechanism may significantly influence the motor development of human being. The study aimed in checking if the deafness, as a result of various unfavourable factors, determines the motor development of children and youngsters. Consequently the dependency between qualitative features i.e.: signed motor level and aetiology, audition injury mechanism and the deafness degree was examined. The mechanism and aetiology of hearing correlated with the motor abilities displayed statistically significant dependencies in few motor trials only. Revealed correlations regarded mostly the coordination trials excluding the flexibility one. Statistically significant dependencies between the audition diminution and the motor abilities level were not found.

  11. Basics of Antibody Phage Display Technology.

    Science.gov (United States)

    Ledsgaard, Line; Kilstrup, Mogens; Karatt-Vellatt, Aneesh; McCafferty, John; Laustsen, Andreas H

    2018-06-09

    Antibody discovery has become increasingly important in almost all areas of modern medicine. Different antibody discovery approaches exist, but one that has gained increasing interest in the field of toxinology and antivenom research is phage display technology. In this review, the lifecycle of the M13 phage and the basics of phage display technology are presented together with important factors influencing the success rates of phage display experiments. Moreover, the pros and cons of different antigen display methods and the use of naïve versus immunized phage display antibody libraries is discussed, and selected examples from the field of antivenom research are highlighted. This review thus provides in-depth knowledge on the principles and use of phage display technology with a special focus on discovery of antibodies that target animal toxins.

  12. Three-dimensional hologram display system

    Science.gov (United States)

    Mintz, Frederick (Inventor); Chao, Tien-Hsin (Inventor); Bryant, Nevin (Inventor); Tsou, Peter (Inventor)

    2009-01-01

    The present invention relates to a three-dimensional (3D) hologram display system. The 3D hologram display system includes a projector device for projecting an image upon a display medium to form a 3D hologram. The 3D hologram is formed such that a viewer can view the holographic image from multiple angles up to 360 degrees. Multiple display media are described, namely a spinning diffusive screen, a circular diffuser screen, and an aerogel. The spinning diffusive screen utilizes spatial light modulators to control the image such that the 3D image is displayed on the rotating screen in a time-multiplexing manner. The circular diffuser screen includes multiple, simultaneously-operated projectors to project the image onto the circular diffuser screen from a plurality of locations, thereby forming the 3D image. The aerogel can use the projection device described as applicable to either the spinning diffusive screen or the circular diffuser screen.

  13. Health status among long-term breast cancer survivors suffering from higher levels of fatigue: a cross-sectional study.

    Science.gov (United States)

    Álvarez-Salvago, Francisco; Galiano-Castillo, Noelia; Arroyo-Morales, Manuel; Cruz-Fernández, Mayra; Lozano-Lozano, Mario; Cantarero-Villanueva, Irene

    2018-05-05

    The aims of this study were to evaluate the health status of long-term breast cancer survivors (LTBCS) suffering from higher levels of fatigue, to highlight their needs, and to establish the key points of intervention support programs. A cross-sectional observational study was conducted at the Sport and Health Joint University Institute (iMUDS) between September 2016 and July 2017 with 80 LTBCS that were classified into non-fatigued (≤ 3.9) or fatigued (≥ 4) according to the Piper Fatigue Scale (PFS) total score. The instruments used were the European Organization for Research and Treatment of Cancer Core 30 and its breast cancer (BC) module, the Visual Analog Scale (VAS), the Brief Pain Inventory (BPI), the Scale for Mood Assessment (EVEA), the International Fitness Scale (IFIS), and the Charlson Comorbidity Index. The analysis revealed that 41.2% of LTBCS were considered moderately fatigued and showed significantly higher levels for the categories of "nausea and vomiting" (P = .005), "pain," "dyspnea" and "insomnia" (P < .001), "appetite loss" (P = .002), "financial difficulties" (P = .010), "systemic therapy side effects" (P < .001), "breast symptoms" and "arm symptoms" (P = .002), and "upset by hair loss" (P = .016). In addition, LTBCS presented significantly higher levels of pain in the affected and non-affected arm, "sadness-depression." "anxiety," "anger/hostility" (All: P < .001), and lower general physical fitness (P < .001). The rest of the variables did not show significant differences. LTBCS suffering from higher levels of fatigue had lower QoL, higher level of pain, worse mood state, and lower physical fitness.

  14. Higher Alu methylation levels in catch-up growth in twenty-year-old offsprings.

    Directory of Open Access Journals (Sweden)

    Kittipan Rerkasem

    Full Text Available Alu elements and long interspersed element-1 (LINE-1 or L1 are two major human intersperse repetitive sequences. Lower Alu methylation, but not LINE-1, has been observed in blood cells of people in old age, and in menopausal women having lower bone mass and osteoporosis. Nevertheless, Alu methylation levels also vary among young individuals. Here, we explored phenotypes at birth that are associated with Alu methylation levels in young people. In 2010, 249 twenty-years-old volunteers whose mothers had participated in a study association between birth weight (BW and nutrition during pregnancy in 1990, were invited to take part in our present study. In this study, the LINE-1 and Alu methylation levels and patterns were measured in peripheral mononuclear cells and correlated with various nutritional parameters during intrauterine and postnatal period of offspring. This included the amount of maternal intake during pregnancy, the mother's weight gain during pregnancy, birth weight, birth length, and the rate of weight gain in the first year of life. Catch-up growth (CUG was defined when weight during the first year was >0.67 of the standard score, according to WHO data. No association with LINE-1 methylation was identified. The mean level of Alu methylation in the CUG group was significantly higher than those non-CUG (39.61% and 33.66 % respectively, P < 0.0001. The positive correlation between the history of CUG in the first year and higher Alu methylation indicates the role of Alu methylation, not only in aging cells, but also in the human growth process. Moreover, here is the first study that demonstrated the association between a phenotype during the newborn period and intersperse repetitive sequences methylation during young adulthood.

  15. Paediatric dose display

    International Nuclear Information System (INIS)

    Griffin, D.W.; Derges, S.; Hesslewood, S.

    1984-01-01

    A compact, inexpensive unit, based on an 8085 microprocessor, has been designed for calculating doses of intravenous radioactive injections for children. It has been used successfully for over a year. The dose is calculated from the body surface area and the result displayed in MBq. The operator can obtain the required dose on a twelve character alphanumeric display by entering the age of the patient and the adult dose using a hexadecimal keyboard. Circuit description, memory map and input/output, and firmware are dealt with. (U.K.)

  16. Finding-specific display presets for computed radiography soft-copy reading.

    Science.gov (United States)

    Andriole, K P; Gould, R G; Webb, W R

    1999-05-01

    Much work has been done to optimize the display of cross-sectional modality imaging examinations for soft-copy reading (i.e., window/level tissue presets, and format presentations such as tile and stack modes, four-on-one, nine-on-one, etc). Less attention has been paid to the display of digital forms of the conventional projection x-ray. The purpose of this study is to assess the utility of providing presets for computed radiography (CR) soft-copy display, based not on the window/level settings, but on processing applied to the image optimized for visualization of specific findings, pathologies, etc (i.e., pneumothorax, tumor, tube location). It is felt that digital display of CR images based on finding-specific processing presets has the potential to: speed reading of digital projection x-ray examinations on soft copy; improve diagnostic efficacy; standardize display across examination type, clinical scenario, important key findings, and significant negatives; facilitate image comparison; and improve confidence in and acceptance of soft-copy reading. Clinical chest images are acquired using an Agfa-Gevaert (Mortsel, Belgium) ADC 70 CR scanner and Fuji (Stamford, CT) 9000 and AC2 CR scanners. Those demonstrating pertinent findings are transferred over the clinical picture archiving and communications system (PACS) network to a research image processing station (Agfa PS5000), where the optimal image-processing settings per finding, pathologic category, etc, are developed in conjunction with a thoracic radiologist, by manipulating the multiscale image contrast amplification (Agfa MUSICA) algorithm parameters. Soft-copy display of images processed with finding-specific settings are compared with the standard default image presentation for 50 cases of each category. Comparison is scored using a 5-point scale with the positive scale denoting the standard presentation is preferred over the finding-specific processing, the negative scale denoting the finding

  17. Scaling Robotic Displays: Displays and Techniques for Dismounted Movement with Robots

    Science.gov (United States)

    2010-04-01

    you are performing the low crawl 4.25 5.00 Drive the robot while you are negotiating the hill 6.00 5.00 Drive the robot while you are climbing the... stairs 4.67 5.00 Drive the robot while you are walking 5.70 5.27 HMD It was fairly doable. 1 When you’re looking through the lens, it’s not...Scaling Robotic Displays: Displays and Techniques for Dismounted Movement with Robots by Elizabeth S. Redden, Rodger A. Pettitt

  18. Associations between social media displays and event-specific alcohol consumption by college students.

    Science.gov (United States)

    Moreno, Megan A; Kacvinsky, Lauren; Pumper, Megan; Wachowski, Leah; Whitehill, Jennifer M

    2013-12-01

    The Mifflin Street Block Party is a yearly Wisconsin event known for high levels of alcohol consumption and previous negative outcomes. This study investigated displayed Mifflin references on Facebook and their association with alcohol consumption at the block party. Participants included first-year college students who were enrolled in a longitudinal study involving Facebook profile assessments and interviews. We identified a subset of participants who were interviewed within 28 days following the Mifflin St Block Party. Participants were categorized as "Mifflin Displayers" or "Non-displayers" based on Facebook profile content. Interviews included the timeline follow-back method to assess alcohol use in the past 28 days. Analysis included logistic and linear regression. Among the 66 participants included in this study, 45 (68.2%) were female and 38 (50%) were Mifflin Displayers on Facebook. Among the Mifflin Displayer participants, 18 (27.2%) displayed prior to Mifflin, 11 displayed the day of Mifflin (16.7%) and 19 (28.8%) displayed after. Some participants displayed in more than 1 time frame. A total of 40 (60.6%) reported alcohol use on the day of the Mifflin Street Block Party. The mean number of drinks reported on the day of Mifflin was 8.8 (SD = 6.1), with a range of 1 to 35. Displayed references to Mifflin on Facebook were positively associated with reporting alcohol use at Mifflin (OR = 20.9, 95% CI 5.6-78.8). Displaying Facebook references to Mifflin was associated with alcohol consumption on the day of the event. Future prevention efforts could consider creating Facebook advertisements with safety messages triggered by Mifflin displays.

  19. Liquid crystal displays with plastic substrates

    Science.gov (United States)

    Lueder, Ernst H.

    1998-04-01

    Plastic substrates for the cells of displays exhibit only 1/6 of the weight of glass substrates; they are virtually unbreakable; their flexibility allows the designer to give them a shape suppressing reflections, to realize a display board on a curved surface or meeting the requirements for an appealing styling; displays with plastics are thinner which provides a wider viewing angle. These features render them attractive for displays in portable systems such as mobile phones, pagers, smart cards, personal digital assistants (PDAs) and portable computers. Reflective displays are especially attractive as they don't need a back light. The most important requirements are the protection of plastics against gas permeation and chemical agents, the prevention of layers on plastics to crack or peel off when the plastic is bent and the development of low temperature thin film processes because the plastics, as a rule, only tolerate temperatures below 150 degrees Celsius. Bistable reflective FLC- and PSCT-displays with plastic substrates will be introduced. Special sputtered SiO2-orientation layers preserve the displayed information even if pressure or torsion is applied. MIM-addressed PDLC-displays require additional Al- or Ti-layers which provide the necessary ductility. Sputtered or PECVD-generated TFTs can be fabricated on plastics at temperatures below 150 degrees Celsius.

  20. A gross anatomy flipped classroom effects performance, retention, and higher-level thinking in lower performing students.

    Science.gov (United States)

    Day, Leslie J

    2018-01-22

    A flipped classroom is a growing pedagogy in higher education. Many research studies on the flipped classroom have focused on student outcomes, with the results being positive or inconclusive. A few studies have analyzed confounding variables, such as student's previous achievement, or the impact of a flipped classroom on long-term retention and knowledge transfer. In the present study, students in a Doctor of Physical Therapy program in a traditional style lecture of gross anatomy (n = 105) were compared to similar students in a flipped classroom (n = 112). Overall, students in the flipped anatomy classroom had an increase in semester average grades (P = 0.01) and performance on higher-level analytical questions (P flipped anatomy classroom performing at a higher level in kinesiology (P flipped anatomy class, outperformed their traditional anatomy class counterparts in anatomy semester grades (P flipped classroom may benefit lower performing student's knowledge acquisition and transfer to a greater degree than higher performing students. Future studies should explore the underlying reasons for improvement in lower performing students. Anat Sci Educ. © 2018 American Association of Anatomists. © 2018 American Association of Anatomists.

  1. Transthyretin knockout mice display decreased susceptibility to AMPA-induced neurodegeneration

    DEFF Research Database (Denmark)

    Nunes, Ana Filipa; Montero, Maria; Franquinho, Filipa

    2009-01-01

    Transthyretin (TTR) has been regarded as a neuroprotective protein given that TTR knockout (KO) mice display increased susceptibility for amyloid beta deposition and memory deficits during aging. In parallel, TTR KO mice have increased levels of neuropeptide Y (NPY), which promotes neuroprotectio...

  2. Plant state display device

    International Nuclear Information System (INIS)

    Kadota, Kazuo; Ito, Toshiichiro.

    1994-01-01

    The device of the present invention conducts information processing suitable for a man to solve a problem in a plant such as a nuclear power plant incorporating a great amount of information, where safety is required and provides information to an operator. Namely, theories and rules with respect to the flow and balanced state of materials and energy upon plant start-up, and a vapor cycle of operation fluids are symbolized and displayed on the display screen of the device. Then, the display of the plant information suitable to the information processing for a man to dissolve problems is provided. Accordingly, a mechanism for analyzing a purpose of the plant is made more definite, thereby enabling to prevent an erroneous judgement of an operator and occurrence of plant troubles. In addition, a simular effect can also be expected when the theories and rules with respect to the flow and the balanced state of materials and energy and thermohydrodynamic behavior of the operation fluids in a state of after-heat removing operation during shutdown of the plant are symbolized and displayed. (I.S.)

  3. Lower serotonin level and higher rate of fibromyalgia syndrome with advancing pregnancy.

    Science.gov (United States)

    Atasever, Melahat; Namlı Kalem, Muberra; Sönmez, Çiğdem; Seval, Mehmet Murat; Yüce, Tuncay; Sahin Aker, Seda; Koç, Acar; Genc, Hakan

    2017-09-01

    The aim of the study is to investigate the relationship between changes in serotonin levels during pregnancy and fibromyalgia syndrome (FS) and the relationships between FS and the physical/psychological state, biochemical and hormonal parameters, which may be related to the musculoskeletal system. This study is a prospective case-control study conducted with 277 pregnant women at the obstetric unit of Ankara University Faculty of Medicine, in the period between January and June 2015. FS was determined based on the presence or absence of the 2010 ACR diagnostic criteria and all the volunteers were asked to answer the questionnaires as Fibromyalgia Impact Criteria (FIQ), Widespread Pain Index (WPI), Symptom Severity Scale (SS), Beck Depression Inventory and Visual Analog Scale (VAS). Biochemical and hormonal markers (glucose, TSH, T4, Ca (calcium), P (phosphate), PTH (parathyroid hormone) and serotonin levels) relating to muscle and bone metabolism were measured. In the presence of fibromyalgia, the physical and psychological parameters are negatively affected (p serotonin levels may contribute to the development of fibromyalgia but this was not statistically significant. The Beck Depression Inventory scale statistically showed that increasing scores also increase the risk of fibromyalgia (p serotonin levels in women with FS are lower than the control group and that serotonin levels reduce as pregnancy progresses. Anxiety and depression in pregnant women with FS are higher than the control group. The presence of depression increases the likelihood of developing FS at a statistically significant level. Serotonin impairment also increases the chance of developing FS, but this correlation has not been shown to be statistically significant.

  4. Multisensory Stimulation to Improve Low- and Higher-Level Sensory Deficits after Stroke: A Systematic Review

    OpenAIRE

    Tinga, Angelica Maria; Visser-Meily, Johanna Maria Augusta; van der Smagt, Maarten Jeroen; Van der Stigchel, Stefan; van Ee, Raymond; Nijboer, Tanja Cornelia Wilhelmina

    2015-01-01

    The aim of this systematic review was to integrate and assess evidence for the effectiveness of multisensory stimulation (i.e., stimulating at least two of the following sensory systems: visual, auditory, and somatosensory) as a possible rehabilitation method after stroke. Evidence was considered with a focus on low-level, perceptual (visual, auditory and somatosensory deficits), as well as higher-level, cognitive, sensory deficits. We referred to the electronic databases Scopus and PubMed to...

  5. Flat-panel video resolution LED display system

    Science.gov (United States)

    Wareberg, P. G.; Kennedy, D. I.

    The system consists of a 128 x 128 element X-Y addressable LED array fabricated from green-emitting gallium phosphide. The LED array is interfaced with a 128 x 128 matrix TV camera. Associated electronics provides for seven levels of grey scale above zero with a grey scale ratio of square root of 2. Picture elements are on 0.008 inch centers resulting in a resolution of 125 lines-per-inch and a display area of approximately 1 sq. in. The LED array concept lends itself to modular construction, permitting assembly of a flat panel screen of any desired size from 1 x 1 inch building blocks without loss of resolution. A wide range of prospective aerospace applications exist extending from helmet-mounted systems involving small dedicated arrays to multimode cockpit displays constructed as modular screens. High-resolution LED arrays are already used as CRT replacements in military film-marking reconnaissance applications.

  6. Efficient, deep-blue TADF-emitters for OLED display applications (Conference Presentation)

    Science.gov (United States)

    Volz, Daniel; Baumann, Thomas

    2016-09-01

    Currently, the mobile display market is strongly shifting towards AMOLED technology, in order to enable curved and flexible displays. This leads to a growing demand for highly efficient OLED emitters to reduce the power consumption and increase display resolution at the same time. While highly efficient green and red OLEDs already found their place in commercial OLED-displays, the lack of efficient blue emitters is still an issue. Consequently, the active area for blue is considerably larger than for green and red pixels, to make up for the lower efficiency. We intend to close this efficiency-gap with novel emitters based on thermally activated delayed fluorescence (TADF) technology. Compared to state-of-the-art fluorescent dopants, the efficiency of TADF-emitters is up to four times higher. At the same time, it is possible to design them in a way to maintain deep blue emission, i.e. CIE y < 0.2. These aspects are relevant to produce efficient high resolution AMOLED displays. Apart from these direct customer benefits, our TADF technology does not contain any rare elements, which allows for the fabrication of sustainable OLED technology. In this work, we highlight one of our recently developed blue TADF materials. Basic material properties as well as first device results are discussed. In a bottom-emitting device, a CIEx/CIEy coordinate of (0.16/0.17) was achieved with efficiency values close to 20% EQE.

  7. Color speckle in laser displays

    Science.gov (United States)

    Kuroda, Kazuo

    2015-07-01

    At the beginning of this century, lighting technology has been shifted from discharge lamps, fluorescent lamps and electric bulbs to solid-state lighting. Current solid-state lighting is based on the light emitting diodes (LED) technology, but the laser lighting technology is developing rapidly, such as, laser cinema projectors, laser TVs, laser head-up displays, laser head mounted displays, and laser headlamps for motor vehicles. One of the main issues of laser displays is the reduction of speckle noise1). For the monochromatic laser light, speckle is random interference pattern on the image plane (retina for human observer). For laser displays, RGB (red-green-blue) lasers form speckle patterns independently, which results in random distribution of chromaticity, called color speckle2).

  8. Different Levels in Orexin Concentrations and Risk Factors Associated with Higher Orexin Levels: Comparison between Detoxified Opiate and Methamphetamine Addicts in 5 Chinese Cities

    Directory of Open Access Journals (Sweden)

    Haoran Zhang

    2013-01-01

    Full Text Available This study sought to explore the degree of orexin levels in Chinese opiate and methamphetamine addicts and the differences between them. The cross-sectional study was conducted among detoxified drug addicts from Mandatory Detoxification Center (MDC in five Chinese cities. Orexin levels were assayed with radioimmunoassay (RIA. Mann-Whitney U test and Kruskal-Wallis test were used to detect differences across groups, and logistic regression was used to explore the association between orexin levels and characteristics of demographic and drug abuse. Between November 2009 and January 2011, 285 opiates addicts, 112 methamphetamine addicts, and 79 healthy controls were enrolled. At drug withdrawal period, both opiate and methamphetamine addicts had lower median orexin levels than controls, and median orexin levels in opiate addicts were higher than those in methamphetamine addicts (all above P<0.05. Adjusted odds of the above median concentration of orexin were higher for injection than “chasing the dragon” (AOR = 3.1, 95% CI = 1.2–7.9. No significant factors associated with orexin levels of methamphetamine addicts were found. Development of intervention method on orexin system by different administration routes especially for injected opiate addicts at detoxification phase may be significant and was welcome.

  9. Three-dimensional Imaging, Visualization, and Display

    CERN Document Server

    Javidi, Bahram; Son, Jung-Young

    2009-01-01

    Three-Dimensional Imaging, Visualization, and Display describes recent developments, as well as the prospects and challenges facing 3D imaging, visualization, and display systems and devices. With the rapid advances in electronics, hardware, and software, 3D imaging techniques can now be implemented with commercially available components and can be used for many applications. This volume discusses the state-of-the-art in 3D display and visualization technologies, including binocular, multi-view, holographic, and image reproduction and capture techniques. It also covers 3D optical systems, 3D display instruments, 3D imaging applications, and details several attractive methods for producing 3D moving pictures. This book integrates the background material with new advances and applications in the field, and the available online supplement will include full color videos of 3D display systems. Three-Dimensional Imaging, Visualization, and Display is suitable for electrical engineers, computer scientists, optical e...

  10. A deterministic model for deteriorating items with displayed inventory level dependent demand rate incorporating marketing decisions with transportation cost

    Directory of Open Access Journals (Sweden)

    A. K. Bhunia

    2011-01-01

    Full Text Available This paper deals with an inventory model, which considers the impact of marketing strategies such as pricing and advertising as well as the displayed inventory level on the demand rate of the system. In addition, the demand rate during the stock-out period differs from that during the stock-in period by a function varied on the waiting time up to the beginning of the next cycle. Shortage are allowed and partially backlogged. Here, the deterioration rate is assumed to follow the Weibull distribution. Considering all these factors with others, different scenarios of the system are investigated. To obtain the solutions of these cases and to illustrate the model, an example is considered. Finally, to study the effects of changes of different parameters of the system, sensitivity analyses have been carried out with respect to the different parameters of the system.

  11. Social interactions in different environments impacts and motivates reproductive displays in college students

    Directory of Open Access Journals (Sweden)

    J. Wortham

    2017-06-01

    Full Text Available Social environments can have an impact on the interactions between the sexes, specifically pre-courtship behaviors. Sexual selection theory may explain social interactions of the sexes, where males display and attract mates more than females. These behaviors may intensify in a sexual environment. It was hypothesized that individuals would display more in a sexualized environment compared to a non-sexualized location. This research sampled N = 880 participants at a university in a southern state in North America and asked which unisex sunglasses they preferred. While the most popular non-showy sunglasses were selected the most, showy new arrival sunglasses were selected more often when the surveyor’s behavior was flirty, compared to normal behavior and dressing sexy. Thus, social interactions such as flirting between the sexes impacted the behaviors of others and increased the intensity of reproductive displays. At the location with sexualized behaviors and dress, individuals selected the non-showy sunglasses, possibly to draw attention to their bodies in swimsuits, whereas at the non-sexy location, new arrivals were chosen at a higher frequency, possibly to stand out when wearing normal clothes. The sexes chose to stand out at equal frequencies as did single participants and people in a relationship, suggesting that all individuals are trying to display and attract mates equally. Social environments impacted display behaviors and the motivation to display is discussed. Keywords: Sociology, Psychology

  12. Computer system for nuclear power plant parameter display

    International Nuclear Information System (INIS)

    Stritar, A.; Klobuchar, M.

    1990-01-01

    The computer system for efficient, cheap and simple presentation of data on the screen of the personal computer is described. The display is in alphanumerical or graphical form. The system can be used for the man-machine interface in the process monitoring system of the nuclear power plant. It represents the third level of the new process computer system of the Nuclear Power Plant Krsko. (author)

  13. SNS online display technologies for EPICS

    International Nuclear Information System (INIS)

    Kasemir, K.U.; Chen, X.; Purcell, J.; Danilova, E.

    2012-01-01

    The ubiquitousness of web clients from personal computers to cell phones results in a growing demand for web-based access to control system data. At the Oak Ridge National Laboratory Spallation Neutron Source (SNS) we have investigated different technical approaches to provide read access to data in the Experimental Physics and Industrial Control System (EPICS) for a wide variety of web client devices. The core web technology, HTTP, is less than ideal for online control system displays. Appropriate use of Ajax, especially the Long Poll paradigm, can alleviate fundamental HTTP limitations. The SNS Status web uses basic Ajax technology to generate generic displays for a wide audience. The Dashboard uses Long Poll and more client-side Java-Script to offer more customization and faster updates for users that need specialized displays. The Web OPI uses RAP for web access to any BOY display, offering utmost flexibility because users can create their own BOY displays in CSS. These three approaches complement each other. Users can access generic status displays with zero effort, invest time in creating their fully customized displays for the Web OPI, or use the Dashboard as an intermediate solution

  14. Dyes for displays

    Science.gov (United States)

    Claussen, U.

    1984-01-01

    The improvement of contrast and visibility of LCD by two different means was undertaken. The two methods are: (1) development of fluorescent dyes to increase the visibility of fluorescent activated displays (FLAD); and (2) development of dichroic dyes to increase the contrast of displays. This work was done in close cooperation with the electronic industry, where the newly synthesized dyes were tested. The targets for the chemical synthesis were selected with the help of computer model calculations. A marketable range of dyes was developed. Since the interest of the electronic industries concerning FLAD was low, the investigations were stopped. Dichroic dyes, especially black mixtures with good light fastness, order parameter, and solubility in nematic phases were developed. The application of these dyes is restricted to indoor use because of an increase of viscosity below -10 C. Applications on a technical scale, e.g., for the automotive industry, will be possible if the displays work at temperatures down to -40 C. This problem requires a complex optimization of the dye/nematic phase system.

  15. Image processing of x-ray left ventricular cineangiocardiograms and displays of cardiac functions

    International Nuclear Information System (INIS)

    Eiho, Shigeru; Yamada, Shigeru; Kuwahara, Michiyoshi

    1980-01-01

    Cineangiocardiography has been often used as one of the highly helpful techniques to examine the cardiac function. This paper deals with the method of tracing automatically the boundaries of the left ventricle on cineangiocardiograms, the method to evaluate and display various cardiac functions, the method to reconstruct the left ventricular cavity from biplane cineangiocardiograms and the method to display a 3-dimensional shape of the left ventricle reconstructed. Our algorithm of boundary tracing is based on a heuristic search for a local maximum of the changing rate in the gray level of cineangiocardiogram. The boundaries of endocardial margins of the left ventricle on 80 to 120 consecutive frames are automatically traced by our method. By using the detected boundaries of the left ventricle, a lot of quantitative information may be established on the cardiac function. The volume change, the wall motions and the %-shortening are displayed graphically. The motion of the boundary of the left ventricle is displayed on a CRT as a moving picture. The left ventricular cavity is reconstructed from the detected boundaries of the left ventricle on biplane cineangiocardiograms. A reconstructed image can be shown as superimposed lines or halftone planes to produce a 3-dimensional perspective. The %-shortening which shows the contractility of the regional myocardium is displayed on a silhouette of the left ventricle. We can easily recognize the abnormal area of contraction and the level and spread of abnormality from this displayed image. With the use of the system described in this paper, we can grasp the movement of the left ventricle exactly and evaluate the cardiac function quantitatively. (author)

  16. Flat panel planar optic display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T. [Brookhaven National Lab., Upton, NY (United States). Dept. of Advanced Technology

    1994-11-01

    A prototype 10 inch flat panel Planar Optic Display, (POD), screen has been constructed and tested. This display screen is comprised of hundreds of planar optic class sheets bonded together with a cladding layer between each sheet where each glass sheet represents a vertical line of resolution. The display is 9 inches wide by 5 inches high and approximately 1 inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  17. Performance of NCAP projection displays

    Science.gov (United States)

    Jones, Philip J.; Tomita, Akira; Wartenberg, Mark

    1991-08-01

    Prototypes of projection displays based on dispersions of liquid crystal in polymer matrices are beginning to appear. The principle of operation depends on electrically switchable light scattering. They are potentially much brighter than current cathode ray tube (CRT) or twisted nematic liquid crystal (TN LC) cell based displays. Comparisons of efficacy and efficiency show this. The contrast and brightness of such displays depend on a combination of the f- number of the projection system and the scattering characteristics of the light valve. Simplified equations can be derived to show these effects. The degree of scattering of current NCAP formulations is sufficient to produce good contrast projection displays, at convenient voltages, that are around three times brighter than TN LC projectors because of the lack of polarizers in the former.

  18. Compressive multi-mode superresolution display

    KAUST Repository

    Heide, Felix

    2014-01-01

    Compressive displays are an emerging technology exploring the co-design of new optical device configurations and compressive computation. Previously, research has shown how to improve the dynamic range of displays and facilitate high-quality light field or glasses-free 3D image synthesis. In this paper, we introduce a new multi-mode compressive display architecture that supports switching between 3D and high dynamic range (HDR) modes as well as a new super-resolution mode. The proposed hardware consists of readily-available components and is driven by a novel splitting algorithm that computes the pixel states from a target high-resolution image. In effect, the display pixels present a compressed representation of the target image that is perceived as a single, high resolution image. © 2014 Optical Society of America.

  19. Auditory display as feedback for a novel eye-tracking system for sterile operating room interaction.

    Science.gov (United States)

    Black, David; Unger, Michael; Fischer, Nele; Kikinis, Ron; Hahn, Horst; Neumuth, Thomas; Glaser, Bernhard

    2018-01-01

    The growing number of technical systems in the operating room has increased attention on developing touchless interaction methods for sterile conditions. However, touchless interaction paradigms lack the tactile feedback found in common input devices such as mice and keyboards. We propose a novel touchless eye-tracking interaction system with auditory display as a feedback method for completing typical operating room tasks. Auditory display provides feedback concerning the selected input into the eye-tracking system as well as a confirmation of the system response. An eye-tracking system with a novel auditory display using both earcons and parameter-mapping sonification was developed to allow touchless interaction for six typical scrub nurse tasks. An evaluation with novice participants compared auditory display with visual display with respect to reaction time and a series of subjective measures. When using auditory display to substitute for the lost tactile feedback during eye-tracking interaction, participants exhibit reduced reaction time compared to using visual-only display. In addition, the auditory feedback led to lower subjective workload and higher usefulness and system acceptance ratings. Due to the absence of tactile feedback for eye-tracking and other touchless interaction methods, auditory display is shown to be a useful and necessary addition to new interaction concepts for the sterile operating room, reducing reaction times while improving subjective measures, including usefulness, user satisfaction, and cognitive workload.

  20. Measuring emotional and cognitive empathy using dynamic, naturalistic, and spontaneous emotion displays.

    Science.gov (United States)

    Buck, Ross; Powers, Stacie R; Hull, Kyle S

    2017-10-01

    Most measures of nonverbal receiving ability use posed expressions as stimuli. As empathy measures, such stimuli lack ecological validity, as the participant is not actually experiencing emotion. An alternative approach uses natural and dynamic displays of spontaneous expressions. The Communication of Affect Receiving Ability Test (CARAT) uses as stimuli spontaneous facial expressions and gestures filmed by an unobtrusive camera of solitary participants responding to emotional images. This article reports the development and initial validation of the CARAT-Spontaneous, Posed, Regulated (CARAT-SPR), which measures both abilities to detect emotion from spontaneous displays (emotion communication accuracy) and to differentiate spontaneous, posed, and regulated displays (expression categorization ability). Although spontaneous displays are natural responses to emotional images, posed displays involve asking the sender to display "as if" responding to a particular sort of image when no image is in fact present (simulation), while Regulated displays involve asking the sender to display "as if" responding to a particular sort of image when an image of opposite valence is in fact present (masking). Expression categorization ability involves judging deception-simulation and masking-and conceptually involves a kind of perspective-taking or cognitive empathy. Emotion communication using spontaneous clips achieved a high level of accuracy and was strongly correlated with ratings of sender expressivity. Expression categorization ability was not significantly correlated with expressivity ratings and was modestly negatively correlated with emotion communication accuracy. In a brief version of the CARAT-SPR, women showed evidence of greater emotion signal detection, whereas men reported greater confidence in expression categorization. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  1. Nuclear image display controller

    International Nuclear Information System (INIS)

    Roth, D.A.

    1985-01-01

    In a nuclear imaging system the digitized x and y coordinates of gamma ray photon emission events address memory locations corresponding to the coordinates. The respective locations are incremented each time they are addressed so at the end of a selected time or event count period the locations contain digital values or raw data corresponding to the intensity of pixels comprising an image frame. The raw data for a frame is coupled to one input of an arithmetic logic unit (ALU) whose output is coupled to a display controller memory. The output of the controller memory is coupled to another ALU input with a feedback bus and is also coupled to a further signal processing circuit which includes means for converting processed data to analog video signals for television display. The ALU is selectively controlled to let raw image data pass through to the display controllor memory or alternately to add (or subtract) raw data for the last image frame developed to the raw data for preceding frames held in the display controller to thereby produce the visual effect on the television screen of an isotope flowing through anatomy

  2. Potentials and limits of electronic situation displays

    International Nuclear Information System (INIS)

    Hable, K.; Hoebler, C.; Bieringer, P.

    2007-01-01

    In the field of precautionary radiation protection and disaster response, the amount of information and the number of its sources is steadily increasing. Central compilation and instant availability of information for all involved authorities becomes more and more important. In this context the structured presentation of documents on a web server in terms of an ''Electronic Situation Display'' (ESD) has been established. In Germany, there are several Electronic Situation Display prototypes run by federal and state authorities for various purposes and using different technical approaches. The systems of the federal states focus on workflow management. They provide emergency log books and information on the implementation of countermeasures for disaster response authorities. The Federal Ministry for the Environment, Nature Conservation and Nuclear Safety (BMU) tasked the Federal Office for Radiation Protection (BfS) to develop the Federal Electronic Situation Display (ELAN) that is mainly used as an information platform for decision making in case of nuclear emergencies. Documents containing radiological data or results from Decision Support Systems are almost automatically integrated into ELAN. Read and write permissions for users are managed by a concept of specific roles. The federal ESD and the systems of the federal states will be coordinated in order to achieve a better harmonisation. Interfaces for data exchange and data processing must be defined. Authorities of the federal states can use protected areas within the federal ESD where information is kept confidential for internal use before it is distributed to other states and federal authorities. In addition, key information of Electronic Situation Displays from the federal states can automatically be integrated into ELAN. Several task groups of the IAEA are working on the development and realization of a prototype for an information platform harmonising ESDs on international level. (orig.)

  3. Higher Levels of Serum Zonulin May Rather Be Associated with Increased Risk of Obesity and Hyperlipidemia, Than with Gastrointestinal Symptoms or Disease Manifestations.

    Science.gov (United States)

    Ohlsson, Bodil; Orho-Melander, Marju; Nilsson, Peter M

    2017-03-08

    Zonulin is considered a biomarker of increased intestinal permeability, and elevated levels have been found in celiac disease. The primary aim of this study was to examine the association between serum zonulin levels and gastrointestinal (GI) symptoms, and secondarily, between zonulin levels and anthropometric and metabolic factors. The offspring ( n = 363) of the participants of the Malmö Diet and Cancer cardiovascular cohort (MDC-CV) were invited to an anthropometric and clinical examination, where fasting plasma glucose levels were measured. Questionnaires about lifestyle factors and medical history were completed along with the Visual Analog Scale for Irritable Bowel Syndrome (VAS-IBS). Zonulin levels were measured in serum by ELISA. Neither GI symptoms nor GI diseases had any influence on zonulin levels. Higher zonulin levels were associated with higher waist circumference ( p = 0.003), diastolic blood pressure ( p = 0.003), and glucose levels ( p = 0.036). Higher zonulin levels were associated with increased risk of overweight ( p zonulin levels among individuals reporting GI symptoms or GI diseases, but higher zonulin levels are associated with higher waist circumference, diastolic blood pressure, fasting glucose, and increased risk of metabolic diseases.

  4. Does peer learning or higher levels of e-learning improve learning abilities? A randomized controlled trial.

    Science.gov (United States)

    Worm, Bjarne Skjødt; Jensen, Kenneth

    2013-01-01

    Background and aims The fast development of e-learning and social forums demands us to update our understanding of e-learning and peer learning. We aimed to investigate if higher, pre-defined levels of e-learning or social interaction in web forums improved students' learning ability. Methods One hundred and twenty Danish medical students were randomized to six groups all with 20 students (eCases level 1, eCases level 2, eCases level 2+, eTextbook level 1, eTextbook level 2, and eTextbook level 2+). All students participated in a pre-test, Group 1 participated in an interactive case-based e-learning program, while Group 2 was presented with textbook material electronically. The 2+ groups were able to discuss the material between themselves in a web forum. The subject was head injury and associated treatment and observation guidelines in the emergency room. Following the e-learning, all students completed a post-test. Pre- and post-tests both consisted of 25 questions randomly chosen from a pool of 50 different questions. Results All students concluded the study with comparable pre-test results. Students at Level 2 (in both groups) improved statistically significant compared to students at level 1 (p>0.05). There was no statistically significant difference between level 2 and level 2+. However, level 2+ was associated with statistically significant greater student's satisfaction than the rest of the students (p>0.05). Conclusions This study applies a new way of comparing different types of e-learning using a pre-defined level division and the possibility of peer learning. Our findings show that higher levels of e-learning does in fact provide better results when compared with the same type of e-learning at lower levels. While social interaction in web forums increase student satisfaction, learning ability does not seem to change. Both findings are relevant when designing new e-learning materials.

  5. Does peer learning or higher levels of e-learning improve learning abilities? A randomized controlled trial

    Science.gov (United States)

    Worm, Bjarne Skjødt; Jensen, Kenneth

    2013-01-01

    Background and aims The fast development of e-learning and social forums demands us to update our understanding of e-learning and peer learning. We aimed to investigate if higher, pre-defined levels of e-learning or social interaction in web forums improved students’ learning ability. Methods One hundred and twenty Danish medical students were randomized to six groups all with 20 students (eCases level 1, eCases level 2, eCases level 2+, eTextbook level 1, eTextbook level 2, and eTextbook level 2+). All students participated in a pre-test, Group 1 participated in an interactive case-based e-learning program, while Group 2 was presented with textbook material electronically. The 2+ groups were able to discuss the material between themselves in a web forum. The subject was head injury and associated treatment and observation guidelines in the emergency room. Following the e-learning, all students completed a post-test. Pre- and post-tests both consisted of 25 questions randomly chosen from a pool of 50 different questions. Results All students concluded the study with comparable pre-test results. Students at Level 2 (in both groups) improved statistically significant compared to students at level 1 (p>0.05). There was no statistically significant difference between level 2 and level 2+. However, level 2+ was associated with statistically significant greater student's satisfaction than the rest of the students (p>0.05). Conclusions This study applies a new way of comparing different types of e-learning using a pre-defined level division and the possibility of peer learning. Our findings show that higher levels of e-learning does in fact provide better results when compared with the same type of e-learning at lower levels. While social interaction in web forums increase student satisfaction, learning ability does not seem to change. Both findings are relevant when designing new e-learning materials. PMID:24229729

  6. Does peer learning or higher levels of e-learning improve learning abilities? A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Bjarne Skjødt Worm

    2013-11-01

    Full Text Available Background and aims : The fast development of e-learning and social forums demands us to update our understanding of e-learning and peer learning. We aimed to investigate if higher, pre-defined levels of e-learning or social interaction in web forums improved students’ learning ability. Methods : One hundred and twenty Danish medical students were randomized to six groups all with 20 students (eCases level 1, eCases level 2, eCases level 2+, eTextbook level 1, eTextbook level 2, and eTextbook level 2+. All students participated in a pre-test, Group 1 participated in an interactive case-based e-learning program, while Group 2 was presented with textbook material electronically. The 2+ groups were able to discuss the material between themselves in a web forum. The subject was head injury and associated treatment and observation guidelines in the emergency room. Following the e-learning, all students completed a post-test. Pre- and post-tests both consisted of 25 questions randomly chosen from a pool of 50 different questions. Results : All students concluded the study with comparable pre-test results. Students at Level 2 (in both groups improved statistically significant compared to students at level 1 (p>0.05. There was no statistically significant difference between level 2 and level 2+. However, level 2+ was associated with statistically significant greater student's satisfaction than the rest of the students (p>0.05. Conclusions : This study applies a new way of comparing different types of e-learning using a pre-defined level division and the possibility of peer learning. Our findings show that higher levels of e-learning does in fact provide better results when compared with the same type of e-learning at lower levels. While social interaction in web forums increase student satisfaction, learning ability does not seem to change. Both findings are relevant when designing new e-learning materials.

  7. On-line data display

    Science.gov (United States)

    Lang, Sherman Y. T.; Brooks, Martin; Gauthier, Marc; Wein, Marceli

    1993-05-01

    A data display system for embedded realtime systems has been developed for use as an operator's user interface and debugging tool. The motivation for development of the On-Line Data Display (ODD) have come from several sources. In particular the design reflects the needs of researchers developing an experimental mobile robot within our laboratory. A proliferation of specialized user interfaces revealed a need for a flexible communications and graphical data display system. At the same time the system had to be readily extensible for arbitrary graphical display formats which would be required for data visualization needs of the researchers. The system defines a communication protocol transmitting 'datagrams' between tasks executing on the realtime system and virtual devices displaying the data in a meaningful way on a graphical workstation. The communication protocol multiplexes logical channels on a single data stream. The current implementation consists of a server for the Harmony realtime operating system and an application written for the Macintosh computer. Flexibility requirements resulted in a highly modular server design, and a layered modular object- oriented design for the Macintosh part of the system. Users assign data types to specific channels at run time. Then devices are instantiated by the user and connected to channels to receive datagrams. The current suite of device types do not provide enough functionality for most users' specialized needs. Instead the system design allows the creation of new device types with modest programming effort. The protocol, design and use of the system are discussed.

  8. Flexible displays, rigid designs?

    DEFF Research Database (Denmark)

    Hornbæk, Kasper

    2015-01-01

    Rapid technological progress has enabled a wide range of flexible displays for computing devices, but the user experience--which we're only beginning to understand--will be the key driver for successful designs.......Rapid technological progress has enabled a wide range of flexible displays for computing devices, but the user experience--which we're only beginning to understand--will be the key driver for successful designs....

  9. Microencapsulated Electrophoretic Films for Electronic Paper Displays

    Science.gov (United States)

    Amundson, Karl

    2003-03-01

    Despite the dominance of liquid crystal displays, they do not perform some functions very well. While backlit liquid crystal displays can offer excellent color performance, they wash out in bright lighting and suffer from high power consumption. Reflective liquid crystal displays have limited brightness, making these devices challenging to read for long periods of time. Flexible liquid crystal displays are difficult to manufacture and keep stable. All of these attributes (long battery lifetime, bright reflective appearance, compatibility with flexible substrates) are traits that would be found in an ideal electronic paper display - an updateable substitute for paper that could be employed in electronic books, newspapers, and other applications. I will discuss technologies that are being developed for electronic-paper-like displays, and especially on particle-based technologies. A microencapsulated electrophoretic display technology is being developed at the E Ink corporation. This display film offers offer high brightness and an ink-on-paper appearance, compatibility with flexible substrates, and image stability that can lead to very low power consumption. I will present some of the physical and chemical challenges associated with making display films with high performance.

  10. Evaluation of inorganic and organic light-emitting diode displays for signage application

    Science.gov (United States)

    Sharma, Pratibha; Kwok, Harry

    2006-08-01

    High-brightness, inorganic light-emitting diodes (LEDs) have been successfully utilized for edge-lighting of large displays for signage. Further interest in solid-state lighting technology has been fueled with the emergence of small molecule and polymer-based organic light-emitting diodes (OLEDs). In this paper, edgelit inorganic LED-based displays and state-of-the-art OLED-based displays are evaluated on the basis of electrical and photometric measurements. The reference size for a signage system is assumed to be 600 mm x 600mm based on the industrial usage. With the availability of high power light-emitting diodes, it is possible to develop edgelit signage systems of the standard size. These displays possess an efficacy of 18 lm/W. Although, these displays are environmentally friendly and efficient, they suffer from some inherent limitations. Homogeneity of displays, which is a prime requirement for illuminated signs, is not accomplished. A standard deviation of 3.12 lux is observed between the illuminance values on the surface of the display. In order to distribute light effectively, reflective gratings are employed. Reflective gratings aid in reducing the problem but fail to eliminate it. In addition, the overall cost of signage is increased by 50% with the use of these additional components. This problem can be overcome by the use of a distributed source of light. Hence, the organic-LEDs are considered as a possible contender. In this paper, we experimentally determine the feasibility of using OLEDs for signage applications and compare their performance with inorganic LEDs. Passive matrix, small-molecule based, commercially available OLEDs is used. Design techniques for implementation of displays using organic LEDs are also discussed. It is determined that tiled displays based on organic LEDs possess better uniformity than the inorganic LED-based displays. However, the currently available OLEDs have lower light-conversion efficiency and higher costs than the

  11. Revisiting the debate on the relationship between display rules and performance: considering the explicitness of display rules.

    Science.gov (United States)

    Christoforou, Paraskevi S; Ashforth, Blake E

    2015-01-01

    We argue that the strength with which the organization communicates expectations regarding the appropriate emotional expression toward customers (i.e., explicitness of display rules) has an inverted U-shaped relationship with service delivery behaviors, customer satisfaction, and sales performance. Further, we argue that service organizations need a particular blend of explicitness of display rules and role discretion for the purpose of optimizing sales performance. As hypothesized, findings from 2 samples of salespeople suggest that either high or low explicitness of display rules impedes service delivery behaviors and sales performance, which peaks at moderate explicitness of display rules and high role discretion. The findings also suggest that the explicitness of display rules has a positive relationship with customer satisfaction. (c) 2015 APA, all rights reserved.

  12. Video display terminals - should operators be concerned

    International Nuclear Information System (INIS)

    Repacholi, M.H.

    1985-01-01

    Although modern offices have traditionally been thought to be among the safest places to work, over the past few years office workers have become concerned that video display terminals could be causing a variety of health problems. Extensive testing has occurred in many countries to determine if VDTs emit hazardous levels of ionizing or non-ionizing radiation. Results of these surveys suggest that radiation emissions are not of concern but that ergonomic factors in the office environment may need to be improved

  13. Software for Minsk-32 display station

    International Nuclear Information System (INIS)

    Belyaeva, L.M.; Gangrskaya, O.G.; Manno, I.; Fefilov, B.V.; Ehsenski, J.

    1976-01-01

    The mathematical provision is described of the Minsk-32 display station. Described is the application of editing program DOSE, assembler translator SLANG and program display-focal. Program DOSE permits to edit the texts with the aid of a rester display on Minsk-32 magnetic tape. The program system permits to use a disk monitor system

  14. An Investigation of Interval Management Displays

    Science.gov (United States)

    Swieringa, Kurt A.; Wilson, Sara R.; Shay, Rick

    2015-01-01

    NASA's first Air Traffic Management (ATM) Technology Demonstration (ATD-1) was created to transition the most mature ATM technologies from the laboratory to the National Airspace System. One selected technology is Interval Management (IM), which uses onboard aircraft automation to compute speeds that help the flight crew achieve and maintain precise spacing behind a preceding aircraft. Since ATD-1 focuses on a near-term environment, the ATD-1 flight demonstration prototype requires radio voice communication to issue an IM clearance. Retrofit IM displays will enable pilots to both enter information into the IM avionics and monitor IM operation. These displays could consist of an interface to enter data from an IM clearance and also an auxiliary display that presents critical information in the primary field-of-view. A human-in-the-loop experiment was conducted to examine usability and acceptability of retrofit IM displays, which flight crews found acceptable. Results also indicate the need for salient alerting when new speeds are generated and the desire to have a primary field of view display available that can display text and graphic trend indicators.

  15. Distributed rendering for multiview parallax displays

    Science.gov (United States)

    Annen, T.; Matusik, W.; Pfister, H.; Seidel, H.-P.; Zwicker, M.

    2006-02-01

    3D display technology holds great promise for the future of television, virtual reality, entertainment, and visualization. Multiview parallax displays deliver stereoscopic views without glasses to arbitrary positions within the viewing zone. These systems must include a high-performance and scalable 3D rendering subsystem in order to generate multiple views at real-time frame rates. This paper describes a distributed rendering system for large-scale multiview parallax displays built with a network of PCs, commodity graphics accelerators, multiple projectors, and multiview screens. The main challenge is to render various perspective views of the scene and assign rendering tasks effectively. In this paper we investigate two different approaches: Optical multiplexing for lenticular screens and software multiplexing for parallax-barrier displays. We describe the construction of large-scale multi-projector 3D display systems using lenticular and parallax-barrier technology. We have developed different distributed rendering algorithms using the Chromium stream-processing framework and evaluate the trade-offs and performance bottlenecks. Our results show that Chromium is well suited for interactive rendering on multiview parallax displays.

  16. Spielräume schulischer Displays

    Directory of Open Access Journals (Sweden)

    Antje Lehn

    2014-03-01

    Full Text Available Antje Lehn zeigt in ihrem Beitrag, wie durch einen erweiterten Display-Begriff in der Schulklasse durch konkrete Projekte Frontalunterricht unterwandert und das Klassenzimmer zu einem ergebnisoffenen Handlungsraum umgestaltet werden kann. Auch Decken, Spiegel, Tische und Spinde sind Displays ...

  17. Lower Squalene Epoxidase and Higher Scavenger Receptor Class B Type 1 Protein Levels Are Involved in Reduced Serum Cholesterol Levels in Stroke-Prone Spontaneously Hypertensive Rats.

    Science.gov (United States)

    Michihara, Akihiro; Mido, Mayuko; Matsuoka, Hiroshi; Mizutani, Yurika

    2015-01-01

    A lower serum cholesterol level was recently shown to be one of the causes of stroke in an epidemiological study. Spontaneously hypertensive rats stroke-prone (SHRSP) have lower serum cholesterol levels than normotensive Wistar-Kyoto rats (WKY). To elucidate the mechanisms responsible for the lower serum cholesterol levels in SHRSP, we determined whether the amounts of cholesterol biosynthetic enzymes or the receptor and transporter involved in cholesterol uptake and efflux in the liver were altered in SHRSP. When the mRNA levels of seven cholesterol biosynthetic enzymes were measured using real-time polymerase chain reaction (PCR), farnesyl pyrophosphate synthase and squalene epoxidase (SQE) levels in the liver of SHRSP were significantly lower than those in WKY. SQE protein levels were significantly reduced in tissues other than the brain of SHRSP. No significant differences were observed in low-density lipoprotein (LDL) receptor (uptake of serum LDL-cholesterol) or ATP-binding cassette transporter A1 (efflux of cholesterol from the liver/formation of high-density lipoprotein (HDL)) protein levels in the liver and testis between SHRSP and WKY, whereas scavenger receptor class B type 1 (SRB1: uptake of serum HDL-cholesterol) protein levels were higher in the livers of SHRSP. These results indicated that the lower protein levels of SQE and higher protein levels of SRB1 in the liver were involved in the reduced serum cholesterol levels in SHRSP.

  18. A passive cooling system proposal for multifunction and high-power displays

    Science.gov (United States)

    Tari, Ilker

    2013-03-01

    Flat panel displays are conventionally cooled by internal natural convection, which constrains the possible rate of heat transfer from the panel. On one hand, during the last few years, the power consumption and the related cooling requirement for 1080p displays have decreased mostly due to energy savings by the switch to LED backlighting and more efficient electronics. However, on the other hand, the required cooling rate recently started to increase with new directions in the industry such as 3D displays, and ultra-high-resolution displays (recent 4K announcements and planned introduction of 8K). In addition to these trends in display technology itself, there is also a trend to integrate consumer entertainment products into displays with the ultimate goal of designing a multifunction device replacing the TV, the media player, the PC, the game console and the sound system. Considering the increasing power requirement for higher fidelity in video processing, these multifunction devices tend to generate very high heat fluxes, which are impossible to dissipate with internal natural convection. In order to overcome this obstacle, instead of active cooling with forced convection that comes with drawbacks of noise, additional power consumption, and reduced reliability, a passive cooling system relying on external natural convection and radiation is proposed here. The proposed cooling system consists of a heat spreader flat heat pipe and aluminum plate-finned heat sink with anodized surfaces. For this system, the possible maximum heat dissipation rates from the standard size panels (in 26-70 inch range) are estimated by using our recently obtained heat transfer correlations for the natural convection from aluminum plate-finned heat sinks together with the surface-to-surface radiation. With the use of the proposed passive cooling system, the possibility of dissipating very high heat rates is demonstrated, hinting a promising green alternative to active cooling.

  19. Performance evaluation of a kinesthetic-tactual display

    Science.gov (United States)

    Jagacinski, R. J.; Flach, J. M.; Gilson, R. D.; Dunn, R. S.

    1982-01-01

    Simulator studies demonstrated the feasibility of using kinesthetic-tactual (KT) displays for providing collective and cyclic command information, and suggested that KT displays may increase pilot workload capability. A dual-axis laboratory tracking task suggested that beyond reduction in visual scanning, there may be additional sensory or cognitive benefits to the use of multiple sensory modalities. Single-axis laboratory tracking tasks revealed performance with a quickened KT display to be equivalent to performance with a quickened visual display for a low frequency sum-of-sinewaves input. In contrast, an unquickened KT display was inferior to an unquickened visual display. Full scale simulator studies and/or inflight testing are recommended to determine the generality of these results.

  20. Effect of display size on visual attention.

    Science.gov (United States)

    Chen, I-Ping; Liao, Chia-Ning; Yeh, Shih-Hao

    2011-06-01

    Attention plays an important role in the design of human-machine interfaces. However, current knowledge about attention is largely based on data obtained when using devices of moderate display size. With advancement in display technology comes the need for understanding attention behavior over a wider range of viewing sizes. The effect of display size on test participants' visual search performance was studied. The participants (N = 12) performed two types of visual search tasks, that is, parallel and serial search, under three display-size conditions (16 degrees, 32 degrees, and 60 degrees). Serial, but not parallel, search was affected by display size. In the serial task, mean reaction time for detecting a target increased with the display size.

  1. Effect of pretreatment of hydrothermally processed rice straw with laccase-displaying yeast on ethanol fermentation

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Akihito; Bae, Jun Gu; Fukai, Kotaro; Tokumoto, Naoki; Kuroda, Kouichi; Ogawa, Jun; Shimizu, Sakayu; Ueda, Mitsuyoshi [Kyoto Univ. (Japan). Div. of Applied Life Sciences; Nakatani, Masato [Daiwa Kasei, Shiga (Japan)

    2012-05-15

    A gene encoding laccase I was identified and cloned from the white-rot fungus Trametes sp. Ha1. Laccase I contained 10 introns and an original secretion signal sequence. After laccase I without introns was prepared by overlapping polymerase chain reaction, it was inserted into expression vector pULD1 for yeast cell surface display. The oxidation activity of a laccase-I-displaying yeast as a whole-cell biocatalyst was examined with 2,2{sup '}-azino-bis(3-ethylbenzthiazoline-6-sulphonic acid) (ABTS), and the constructed yeast showed a high oxidation activity. After the pretreatment of hydrothermally processed rice straw (HPRS) with laccase-I-displaying yeast with ABTS, fermentation was conducted with yeast codisplaying endoglucanase, cellobiohydrolase, and {beta}-glucosidase with HPRS. Fermentation of HPRS treated with laccase-I-displaying yeast was performed with 1.21-fold higher activities than those of HPRS treated with control yeast. The results indicated that pretreatment with laccase-I-displaying yeast with ABTS was effective for direct fermentation of cellulosic materials by yeast codisplaying endoglucanase, cellobiohydrolase, and {beta}-glucosidase. (orig.)

  2. Exploring interaction with 3D volumetric displays

    Science.gov (United States)

    Grossman, Tovi; Wigdor, Daniel; Balakrishnan, Ravin

    2005-03-01

    Volumetric displays generate true volumetric 3D images by actually illuminating points in 3D space. As a result, viewing their contents is similar to viewing physical objects in the real world. These displays provide a 360 degree field of view, and do not require the user to wear hardware such as shutter glasses or head-trackers. These properties make them a promising alternative to traditional display systems for viewing imagery in 3D. Because these displays have only recently been made available commercially (e.g., www.actuality-systems.com), their current use tends to be limited to non-interactive output-only display devices. To take full advantage of the unique features of these displays, however, it would be desirable if the 3D data being displayed could be directly interacted with and manipulated. We investigate interaction techniques for volumetric display interfaces, through the development of an interactive 3D geometric model building application. While this application area itself presents many interesting challenges, our focus is on the interaction techniques that are likely generalizable to interactive applications for other domains. We explore a very direct style of interaction where the user interacts with the virtual data using direct finger manipulations on and around the enclosure surrounding the displayed 3D volumetric image.

  3. SoftCopy Display Quality Assurance Program at Texas Children's Hospital.

    Science.gov (United States)

    Ly, Catherine Kim

    2002-01-01

    With growing dependence on picture archiving and communication systems for viewing images, a quality assurance program to monitor the condition of workstation displays has become increasingly important. At present there is no universally accepted program for PACS, but there are groups such as DICOM Working Group 11 of the ACR-NEMA and AAPM Task Group 18 that are working on image quality guidelines for interpretation from soft-copy displays. Texas Children's Hospital (TCH) is developing our own quality assurance program. Data is being collected to determine the appropriate frequency of calibration, the useful life of the displays, appropriate manufacturers, and model-dependent limits on maximum and minimum luminance (black level), symptoms of degradation, and monitor cleanliness. Our system includes a variety of monitors manufactured by Sun, AFP, Siemens, Image Systems, Barco, and Orwin. We are presently collecting data on individual monitor luminance functions but have not yet initiated service calls based on deviation from the DICOM Part 14 Grayscale Display Function (GSDF). The GSDF was intended to produce a grayscale in which driving levels produce changes in luminance that are perceptually equivalent throughout the entire luminance range for a specific test target. Our data is based on measurements of luminance from a digital Society of Motion Picture and Television Engineers (SMPTE) test pattern, which is a standard used by many other institutions. TCH's biomedical engineer measures luminance data each month from the display of the SMPTE pattern and record the results in a spreadsheet. The engineer also makes subjective evaluations of sharpness, geometric distortion, and artifacts. When a monitor's luminance falls outside of arbitrary 10% limits of maximum or minimum luminance, then a service call is placed to the vendor. The luminance check by the biomedical engineer is used to verify both routine and unscheduled calibrations. In addition to the monthly

  4. Higher Levels of Serum Zonulin May Rather Be Associated with Increased Risk of Obesity and Hyperlipidemia, Than with Gastrointestinal Symptoms or Disease Manifestations

    Directory of Open Access Journals (Sweden)

    Bodil Ohlsson

    2017-03-01

    Full Text Available Zonulin is considered a biomarker of increased intestinal permeability, and elevated levels have been found in celiac disease. The primary aim of this study was to examine the association between serum zonulin levels and gastrointestinal (GI symptoms, and secondarily, between zonulin levels and anthropometric and metabolic factors. The offspring (n = 363 of the participants of the Malmö Diet and Cancer cardiovascular cohort (MDC-CV were invited to an anthropometric and clinical examination, where fasting plasma glucose levels were measured. Questionnaires about lifestyle factors and medical history were completed along with the Visual Analog Scale for Irritable Bowel Syndrome (VAS-IBS. Zonulin levels were measured in serum by ELISA. Neither GI symptoms nor GI diseases had any influence on zonulin levels. Higher zonulin levels were associated with higher waist circumference (p = 0.003, diastolic blood pressure (p = 0.003, and glucose levels (p = 0.036. Higher zonulin levels were associated with increased risk of overweight (p < 0.001, obesity (p = 0.047, and hyperlipidemia (p = 0.048. We cannot detect altered zonulin levels among individuals reporting GI symptoms or GI diseases, but higher zonulin levels are associated with higher waist circumference, diastolic blood pressure, fasting glucose, and increased risk of metabolic diseases.

  5. Volume scanning three-dimensional display with an inclined two-dimensional display and a mirror scanner

    Science.gov (United States)

    Miyazaki, Daisuke; Kawanishi, Tsuyoshi; Nishimura, Yasuhiro; Matsushita, Kenji

    2001-11-01

    A new three-dimensional display system based on a volume-scanning method is demonstrated. To form a three-dimensional real image, an inclined two-dimensional image is rapidly moved with a mirror scanner while the cross-section patterns of a three-dimensional object are displayed sequentially. A vector-scan CRT display unit is used to obtain a high-resolution image. An optical scanning system is constructed with concave mirrors and a galvanometer mirror. It is confirmed that three-dimensional images, formed by the experimental system, satisfy all the criteria for human stereoscopic vision.

  6. A pocket warning γ-dosimeter with numerical display

    International Nuclear Information System (INIS)

    Jones, A.R.

    1980-09-01

    A pocket warning dosimeter is described. It provides alarms (continuous tone and a flashing red light) when a presettable dose has been accumulated in the range .064 - 16.4 rads (0.64 - 164 μGy). This warning level can be selected in nine steps of 2 with a switch inside the dosimeter. The dose rate is indicated by a series of sound pulses whose repetition rate is proportional to the dose rate. At 1 rad/h (10 mGy/h) about 17 pluses/minute are emitted. The accumulated dose up to 20 rads (0.2 Gy) is displayed in steps of 1 mrad (10 μGy) with a liquid crystal display. A red LED lights before battery failure occurs. The effects of changes in temperature, battery voltage, dose rate and photon energy upon dosimeter sensitivity are presented. Finally, the applications of the dosimeter are discussed. (auth)

  7. Identifying and Fostering Higher Levels of Geometric Thinking

    Science.gov (United States)

    Škrbec, Maja; Cadež, Tatjana Hodnik

    2015-01-01

    Pierre M. Van Hiele created five levels of geometric thinking. We decided to identify the level of geometric thinking in the students in Slovenia, aged 9 to 11 years. The majority of students (60.7%) are at the transition between the zero (visual) level and the first (descriptive) level of geometric thinking. Nearly a third (31.7%) of students is…

  8. Refreshing Refreshable Braille Displays.

    Science.gov (United States)

    Russomanno, Alexander; O'Modhrain, Sile; Gillespie, R Brent; Rodger, Matthew W M

    2015-01-01

    The increased access to books afforded to blind people via e-publishing has given them long-sought independence for both recreational and educational reading. In most cases, blind readers access materials using speech output. For some content such as highly technical texts, music, and graphics, speech is not an appropriate access modality as it does not promote deep understanding. Therefore blind braille readers often prefer electronic braille displays. But, these are prohibitively expensive. The search is on, therefore, for a low-cost refreshable display that would go beyond current technologies and deliver graphical content as well as text. And many solutions have been proposed, some of which reduce costs by restricting the number of characters that can be displayed, even down to a single braille cell. In this paper, we demonstrate that restricting tactile cues during braille reading leads to poorer performance in a letter recognition task. In particular, we show that lack of sliding contact between the fingertip and the braille reading surface results in more errors and that the number of errors increases as a function of presentation speed. These findings suggest that single cell displays which do not incorporate sliding contact are likely to be less effective for braille reading.

  9. Noninjured Knees of Patients With Noncontact ACL Injuries Display Higher Average Anterior and Internal Rotational Knee Laxity Compared With Healthy Knees of a Noninjured Population.

    Science.gov (United States)

    Mouton, Caroline; Theisen, Daniel; Meyer, Tim; Agostinis, Hélène; Nührenbörger, Christian; Pape, Dietrich; Seil, Romain

    2015-08-01

    Excessive physiological anterior and rotational knee laxity is thought to be a risk factor for noncontact anterior cruciate ligament (ACL) injuries and inferior reconstruction outcomes, but no thresholds have been established to identify patients with increased laxity. (1) To determine if the healthy contralateral knees of ACL-injured patients have greater anterior and rotational knee laxity, leading to different laxity profiles (combination of laxities), compared with healthy control knees and (2) to set a threshold to help discriminate anterior and rotational knee laxity between these groups. Case-sectional study; Level of evidence, 3. A total of 171 healthy contralateral knees of noncontact ACL-injured patients (ACL-H group) and 104 healthy knees of control participants (CTL group) were tested for anterior and rotational laxity. Laxity scores (measurements corrected for sex and body mass) were used to classify knees as hypolax (score 1). Proportions of patients in each group were compared using χ(2) tests. Receiver operating characteristic curves were computed to discriminate laxity between the groups. Odds ratios were calculated to determine the probability of being in the ACL-H group. The ACL-H group displayed greater laxity scores for anterior displacement and internal rotation in their uninjured knee compared with the CTL group (P knees of patients with noncontact ACL injuries display different laxity values both for internal rotation and anterior displacement compared with healthy control knees. The identification of knee laxity profiles may be of relevance for primary and secondary prevention programs of noncontact ACL injuries. © 2015 The Author(s).

  10. Gamma camera display system

    International Nuclear Information System (INIS)

    Stout, K.J.

    1976-01-01

    A gamma camera having an array of photomultipliers coupled via pulse shaping circuitry and a resistor weighting circuit to a display for forming an image of a radioactive subject is described. A linearizing circuit is coupled to the weighting circuit, the linearizing circuit including a nonlinear feedback circuit with diode coupling to the weighting circuit for linearizing the correspondence between points of the display and points of the subject. 4 Claims, 5 Drawing Figures

  11. Pakistanis living in Oslo have lower serum 1,25-dihydroxyvitamin D levels but higher serum ionized calcium levels compared with ethnic Norwegians. The Oslo Health Study

    Science.gov (United States)

    Holvik, Kristin; Meyer, Haakon E; Søgaard, Anne Johanne; Haug, Egil; Falch, Jan A

    2007-01-01

    Background Persons of Pakistani origin living in Oslo have a much higher prevalence of vitamin D deficiency and secondary hyperparathyroidism but similar bone mineral density compared with ethnic Norwegians. Our objective was to investigate whether Pakistani immigrants living in Oslo have an altered vitamin D metabolism by means of compensatory higher serum levels of 1,25-dihydroxyvitamin D (s-1,25(OH)2D) compared with ethnic Norwegians; and whether serum levels of ionized calcium (s-Ca2+) differ between Pakistanis and Norwegians. Methods In a cross-sectional, population-based study venous serum samples were drawn from 94 Pakistani men and 67 Pakistani women aged 30–60 years, and 290 Norwegian men and 270 Norwegian women aged 45–60 years; in total 721 subjects. Results Pakistanis had lower s-1,25(OH)2D compared with Norwegians (p Oslo with low vitamin D status and secondary hyperparathyroidism have lower s-1,25(OH)2D compared with ethnic Norwegians. However, the Pakistanis have higher s-Ca2+. The cause of the higher s-Ca2+ in Pakistanis in spite of their higher iPTH remains unclear. PMID:17945003

  12. Information Display: Considerations for Designing Modern Computer-Based Display Systems

    International Nuclear Information System (INIS)

    O'Hara, J.; Pirus, D.; Beltracchi, L.

    2003-01-01

    OAK- B135 To help nuclear utilities and suppliers design and implement plant information management systems and displays that provide accurate and timely information and require minimal navigation and interface management

  13. Transgenic banana plants overexpressing a native plasma membrane aquaporin MusaPIP1;2 display high tolerance levels to different abiotic stresses.

    Science.gov (United States)

    Sreedharan, Shareena; Shekhawat, Upendra K S; Ganapathi, Thumballi R

    2013-10-01

    Water transport across cellular membranes is regulated by a family of water channel proteins known as aquaporins (AQPs). As most abiotic stresses like suboptimal temperatures, drought or salinity result in cellular dehydration, it is imperative to study the cause-effect relationship between AQPs and the cellular consequences of abiotic stress stimuli. Although plant cells have a high isoform diversity of AQPs, the individual and integrated roles of individual AQPs in optimal and suboptimal physiological conditions remain unclear. Herein, we have identified a plasma membrane intrinsic protein gene (MusaPIP1;2) from banana and characterized it by overexpression in transgenic banana plants. Cellular localization assay performed using MusaPIP1;2::GFP fusion protein indicated that MusaPIP1;2 translocated to plasma membrane in transformed banana cells. Transgenic banana plants overexpressing MusaPIP1;2 constitutively displayed better abiotic stress survival characteristics. The transgenic lines had lower malondialdehyde levels, elevated proline and relative water content and higher photosynthetic efficiency as compared to equivalent controls under different abiotic stress conditions. Greenhouse-maintained hardened transgenic plants showed faster recovery towards normal growth and development after cessation of abiotic stress stimuli, thereby underlining the importance of these plants in actual environmental conditions wherein the stress stimuli is often transient but severe. Further, transgenic plants where the overexpression of MusaPIP1;2 was made conditional by tagging it with a stress-inducible native dehydrin promoter also showed similar stress tolerance characteristics in in vitro and in vivo assays. Plants developed in this study could potentially enable banana cultivation in areas where adverse environmental conditions hitherto preclude commercial banana cultivation. © 2013 Society for Experimental Biology, Association of Applied Biologists and John Wiley & Sons

  14. Systemic Glucose Level Changes with a Carbohydrate-Restricted and Higher Protein Diet Combined with Exercise

    Science.gov (United States)

    Bowden, Rodney G.; Lanning, Beth A.; Doyle, Eva I.; Slonaker, Becky; Johnston, Holly M.; Scanes, Georgene

    2007-01-01

    Objective: The authors' purpose in this study was to compare the effects of macronutrient intake on systemic glucose levels in previously sedentary participants who followed 1 of 4 diets that were either higher protein or high carbohydrate, while initiating an exercise program. Participants and Methods: The authors randomly assigned 94 sedentary…

  15. Emotional Labour in University Lecturers: Considerations for Higher Education Institutions

    Science.gov (United States)

    Berry, Karen; Cassidy, Simon

    2013-01-01

    Emotional labour is a state that exists when there is a discrepancy between the emotional demeanour that an individual displays and the genuinely felt emotions that would be inappropriate to display (Mann 1999b).The study examined levels of emotional labour in university lecturers and compared these data to other occupations. Employing a mixed…

  16. Refreshable Braille displays using EAP actuators

    Science.gov (United States)

    Bar-Cohen, Yoseph

    2010-04-01

    Refreshable Braille can help visually impaired persons benefit from the growing advances in computer technology. The development of such displays in a full screen form is a great challenge due to the need to pack many actuators in small area without interferences. In recent years, various displays using actuators such as piezoelectric stacks have become available in commercial form but most of them are limited to one line Braille code. Researchers in the field of electroactive polymers (EAP) investigated methods of using these materials to form full screen displays. This manuscript reviews the state of the art of producing refreshable Braille displays using EAP-based actuators.

  17. Refreshable Braille Displays Using EAP Actuators

    Science.gov (United States)

    Bar-Cohen, Yoseph

    2010-01-01

    Refreshable Braille can help visually impaired persons benefit from the growing advances in computer technology. The development of such displays in a full screen form is a great challenge due to the need to pack many actuators in small area without interferences. In recent years, various displays using actuators such as piezoelectric stacks have become available in commercial form but most of them are limited to one line Braille code. Researchers in the field of electroactive polymers (EAP) investigated methods of using these materials to form full screen displays. This manuscript reviews the state of the art of producing refreshable Braille displays using EAP-based actuators..

  18. Bacterial whole-cell biocatalysts by surface display of enzymes: toward industrial application.

    Science.gov (United States)

    Schüürmann, Jan; Quehl, Paul; Festel, Gunter; Jose, Joachim

    2014-10-01

    Despite the first report on the bacterial display of a recombinant peptide appeared almost 30 years ago, industrial application of cells with surface-displayed enzymes is still limited. To display an enzyme on the surface of a living cell bears several advantages. First of all, neither the substrate nor the product of the enzymatic reaction needs to cross a membrane barrier. Second, the enzyme being linked to the cell can be separated from the reaction mixture and hence the product by simple centrifugation. Transfer to a new substrate preparation results in multiple cycles of enzymatic conversion. Finally, the anchoring in a matrix, in this case, the cell envelope stabilizes the enzyme and makes it less accessible to proteolytic degradation and material adsorption resulting in continuous higher activities. These advantages in common need to balance some disadvantages before this application can be taken into account for industrial processes, e.g., the exclusion of the enzyme from the cellular metabolome and hence from redox factors or other co-factors that need to be supplied. Therefore, this digest describes the different systems in Gram-positive and Gram-negative bacteria that have been used for the surface display of enzymes so far and focuses on examples among these which are suitable for industrial purposes or for the production of valuable resources, not least in order to encourage a broader application of whole-cell biocatalysts with surface-displayed enzymes.

  19. System Would Generate Virtual Heads-Up Display

    Science.gov (United States)

    Lambert, James L.

    1994-01-01

    Proposed helmet-mounted electronic display system superimposes full-color alphanumerical and/or graphical information onto observer's visual field. Displayed information projected directly onto observer's retinas, giving observer illusion of full-size computer display in foreground or background. Display stereoscopic, holographic, or in form of virtual image. Used by pilots to view navigational information while looking outside or at instruments, by security officers to view information about critical facilities while looking at visitors, or possibly even stock-exchange facilities to view desktop monitors and overhead displays simultaneously. System includes acousto-optical tunable filter (AOTF), which acts as both spectral filter and spatial light modulator.

  20. Manufacturing considerations for AMLCD cockpit displays

    Science.gov (United States)

    Luo, Fang-Chen

    1995-06-01

    AMLCD cockpit displays need to meet more stringent requirements compared with AMLCD commercial displays in areas such as environmental conditions, optical performance and device reliability. Special considerations are required for the manufacturing of AMLCD cockpit displays in each process step to address these issues. Some examples are: UV stable polarizers, wide-temperature LC material, strong LC glue seal, ESS test system, gray scale voltage EEPROM, etc.

  1. Biomechanics of the Peacock's Display: How Feather Structure and Resonance Influence Multimodal Signaling.

    Science.gov (United States)

    Dakin, Roslyn; McCrossan, Owen; Hare, James F; Montgomerie, Robert; Amador Kane, Suzanne

    2016-01-01

    Courtship displays may serve as signals of the quality of motor performance, but little is known about the underlying biomechanics that determines both their signal content and costs. Peacocks (Pavo cristatus) perform a complex, multimodal "train-rattling" display in which they court females by vibrating the iridescent feathers in their elaborate train ornament. Here we study how feather biomechanics influences the performance of this display using a combination of field recordings and laboratory experiments. Using high-speed video, we find that train-rattling peacocks stridulate their tail feathers against the train at 25.6 Hz, on average, generating a broadband, pulsating mechanical sound at that frequency. Laboratory measurements demonstrate that arrays of peacock tail and train feathers have a broad resonant peak in their vibrational spectra at the range of frequencies used for train-rattling during the display, and the motion of feathers is just as expected for feathers shaking near resonance. This indicates that peacocks are able to drive feather vibrations energetically efficiently over a relatively broad range of frequencies, enabling them to modulate the feather vibration frequency of their displays. Using our field data, we show that peacocks with longer trains use slightly higher vibration frequencies on average, even though longer train feathers are heavier and have lower resonant frequencies. Based on these results, we propose hypotheses for future studies of the function and energetics of this display that ask why its dynamic elements might attract and maintain female attention. Finally, we demonstrate how the mechanical structure of the train feathers affects the peacock's visual display by allowing the colorful iridescent eyespots-which strongly influence female mate choice-to remain nearly stationary against a dynamic iridescent background.

  2. "It Looks Like an Adult Sweetie Shop": Point-of-Sale Tobacco Display Exposure and Brand Awareness in Scottish Secondary School Students.

    Science.gov (United States)

    van der Sluijs, Winfried; Haseen, Farhana; Miller, Martine; MacGregor, Andy; Sharp, Clare; Amos, Amanda; Best, Catherine; Stead, Martine; Eadie, Douglas; Pearce, Jamie; Frank, John; Haw, Sally

    2016-10-01

    As further restrictions have been placed on tobacco advertising and promotions, point-of-sale (PoS) displays of cigarettes in shops have become an increasingly important source of young people's exposure to tobacco products. This study explored the relationship between PoS displays of cigarettes and brand awareness among secondary school students in Scotland. Cross-sectional school surveys (n = 1406) and focus groups (n = 86) were conducted with S2 (13-14 years) and S4 (15-16 years) students in four schools of differing socioeconomic status in 2013, prior to the PoS display ban in large shops. Adjusted negative binomial regression analysis examined associations between brand awareness and exposure variables (visiting tobacco retailers, noticing displays of tobacco products). Students visiting small shops more frequently (relative rate ratio [RRR] 1.19, 95% confidence interval [CI] 1.01-1.41) and those who noticed cigarette displays in small shops (RRR 1.24, 95% CI 1.03-1.51) and large supermarkets (RRR 1.15, 95% CI 1.01-1.30) had higher brand awareness. The focus groups supported these findings. Participants described PoS tobacco displays as being eye-catching, colorful and potentially attractive to young people. This mixed-methods study showed that higher cigarette brand awareness was significantly associated with regularly visiting small shops and noticing PoS displays in small and large shops, even when students' smoking status, smoking in their social networks, leisure activities, and demographics were included as confounding variables. This highlights the importance of PoS displays of tobacco products in increasing brand awareness, which is known to increase youth smoking susceptibility, and thus the importance of implementing PoS display bans in all shops. As increasing restrictions have been placed on tobacco promotion in many countries, PoS displays of cigarettes in shops have become an important source of young people's exposure to tobacco products and

  3. Subjective quality of videos displayed with local backlight dimming at different peak white and ambient light levels

    DEFF Research Database (Denmark)

    Mantel, Claire; Korhonen, Jari; Forchhammer, Søren

    2015-01-01

    In this paper the influence of ambient light and peak white (maximum brightness) of a display on the subjective quality of videos shown with local backlight dimming is examined. A subjective experiment investigating those factors is set-up using high contrast test sequences. The results are firstly...

  4. Designing low cost LED display for the billboard

    Science.gov (United States)

    Hong, Yi-Jian; Uang, Chii-Maw; Wang, Ping-Chieh; Ho, Zu-Sheng

    2011-10-01

    With quickly advance of the computer, microelectronics and photonics technologies, LED display panel becomes a new electronic advertising media. It can be used to show any information whatever characters or graphics. Most LED display panels are built of many Light-Emitting Diodes arranged in a matrix form. The display has many advantages such as low power, low cost, long life and high definition. Because the display panel is asked to show rich color, the LED display panel's driving system becomes very complex. The design methodology of LED display panel's driver becomes more and more important to meet the market requirements. Cost is always the most important issue in public market domain. In this paper, we report a design methodology of LED display panel's driver based on the microprocessor control unit (MCU) system and LED display controller IC, HT1632C, to control three colors, RGB, color LED display panel and the modular panel size is 24*16 in matrix form. The HT1632C is a memory mapping LED display controller, it can be used on many applications, such as digital clock, thermometer, counter, voltmeter or other instrumentation readouts. Three pieces of HT1632C are used to drive a 24*16 RGB LED display panel, in our design case. Each HT163C chip is used to control one of the R, G and B color. As the drive mode is driven in DC mode, the RGB display panel can create and totally of seven colors under the control of MCU. The MCU generates the control signal to drive HT1632C. In this study, the software design methodology is adopted with dynamic display principle. When the scan frequency is 60Hz, LED display panel will get the clear picture and be able to display seven colors.

  5. ColorPhylo: A Color Code to Accurately Display Taxonomic Classifications.

    Science.gov (United States)

    Lespinats, Sylvain; Fertil, Bernard

    2011-01-01

    Color may be very useful to visualise complex data. As far as taxonomy is concerned, color may help observing various species' characteristics in correlation with classification. However, choosing the number of subclasses to display is often a complex task: on the one hand, assigning a limited number of colors to taxa of interest hides the structure imbedded in the subtrees of the taxonomy; on the other hand, differentiating a high number of taxa by giving them specific colors, without considering the underlying taxonomy, may lead to unreadable results since relationships between displayed taxa would not be supported by the color code. In the present paper, an automatic color coding scheme is proposed to visualise the levels of taxonomic relationships displayed as overlay on any kind of data plot. To achieve this goal, a dimensionality reduction method allows displaying taxonomic "distances" onto a Euclidean two-dimensional space. The resulting map is projected onto a 2D color space (the Hue, Saturation, Brightness colorimetric space with brightness set to 1). Proximity in the taxonomic classification corresponds to proximity on the map and is therefore materialised by color proximity. As a result, each species is related to a color code showing its position in the taxonomic tree. The so called ColorPhylo displays taxonomic relationships intuitively and can be combined with any biological result. A Matlab version of ColorPhylo is available at http://sy.lespi.free.fr/ColorPhylo-homepage.html. Meanwhile, an ad-hoc distance in case of taxonomy with unknown edge lengths is proposed.

  6. Projection displays and MEMS: timely convergence for a bright future

    Science.gov (United States)

    Hornbeck, Larry J.

    1995-09-01

    Projection displays and microelectromechanical systems (MEMS) have evolved independently, occasionally crossing paths as early as the 1950s. But the commercially viable use of MEMS for projection displays has been illusive until the recent invention of Texas Instruments Digital Light Processing TM (DLP) technology. DLP technology is based on the Digital Micromirror DeviceTM (DMD) microchip, a MEMS technology that is a semiconductor digital light switch that precisely controls a light source for projection display and hardcopy applications. DLP technology provides a unique business opportunity because of the timely convergence of market needs and technology advances. The world is rapidly moving to an all- digital communications and entertainment infrastructure. In the near future, most of the technologies necessary for this infrastrucutre will be available at the right performance and price levels. This will make commercially viable an all-digital chain (capture, compression, transmission, reception decompression, hearing, and viewing). Unfortunately, the digital images received today must be translated into analog signals for viewing on today's televisions. Digital video is the final link in the all-digital infrastructure and DLP technoogy provides that link. DLP technology is an enabler for digital, high-resolution, color projection displays that have high contrast, are bright, seamless, and have the accuracy of color and grayscale that can be achieved only by digital control. This paper contains an introduction to DMD and DLP technology, including the historical context from which to view their developemnt. The architecture, projection operation, and fabrication are presented. Finally, the paper includes an update about current DMD business opportunities in projection displays and hardcopy.

  7. [Application of the grayscale standard display function to general purpose liquid-crystal display monitors for clinical use].

    Science.gov (United States)

    Tanaka, Nobukazu; Naka, Kentaro; Sueoka, Masaki; Higashida, Yoshiharu; Morishita, Junji

    2010-01-20

    Interpretations of medical images have been shifting to soft-copy readings with liquid-crystal display (LCD) monitors. The display function of the medical-grade LCD monitor for soft-copy readings is recommended to calibrate the grayscale standard display function (GSDF) in accordance with the guidelines of Japan and other countries. In this study, the luminance and display function of five models of eight general purpose LCD monitors were measured to gain an understanding of their characteristics. Moreover, the display function (gamma 2.2 or gamma 1.8) of general purpose LCD monitors was converted to GSDF through the use of a look-up table, and the detectability of a simulated lung nodule in the chest x-ray image was examined. As a result, the maximum luminance, contrast ratio, and luminance uniformity of general purpose LCD monitors, except for one model of two LCD monitors, met the management grade 1 standard in the guideline JESRA X-0093-2005. In addition, the detectability of simulated lung nodule in the mediastinal space was obviously improved by converting the display function of a general purpose LCD monitor into GSDF.

  8. Stress Coping Levels and Mental States of Police Vocational School of Higher Education Students

    Directory of Open Access Journals (Sweden)

    Arzu Yildirim

    2011-06-01

    Full Text Available SUMMARY AIM: This study was planned and carried out with the objective of determining stress coping levels and mental state of students attending Police Vocational Schools of Higher Education, in addition to factors effecting these. MATERIAL and METHOD: This desciptive and cross-sectional study consisted of 300 male students enrolled in the 2005-2006 academic year, at Police Vocational School of Higher Education, located in central Erzincan, Turkey. In this study, instead of random sampling, 281 (93.7% students who were present at the school at the time of the study and accepted to partipate in it were included. Data for this study was collected using a desciptive form created by the researchers, Rosenbaum’s Learned Resourcefulness Scale (RLRS and The Symptom Check List-90-R (SCL-90-R. During the data analysis, frequency distributions, Mann-Whitney U, Kruskal-Wallis and analysis of variance (one-way ANOVA were used; and for analysis of independent groups, t-test was used. RESULTS: Among the students, it was determined that 54.8% were 1. grade, 90.7% had their parents living together, 43.5% had a father and 60.5% had a mother who graduated from elementary school, fathers of 23.5% of students were retired, 93.6% of them had mothers who were home makers. In addition, it was found out that 78.6% of students chose their profession willingly, the average family income of 71.5% of students were at medium levels, 82.9% always believed in themselves and 63.3% of students did not smoke. Based on the results obtained, it was observed that second grade students, those with mothers who are highly educated and those who trusted themselved all the time had significantly high stress coping levels; students who chose their own profession, believed in themselves and did not smoke had significantly low levels of mental symptom indications. CONCLUSION: In this study, the students were determined to posess averge levels of stress coping skills and they were found

  9. Soft tissue segmentation and 3D display from computerized tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Fan, R.T.; Trivedi, S.S.; Fellingham, L.L.; Gamboa-Aldeco, A.; Hedgcock, M.W.

    1987-01-01

    Volume calculation and 3D display of human anatomy facilitate a physician's diagnosis, treatment, and evaluation. Accurate segmentation of soft tissue structures is a prerequisite for such volume calculations and 3D displays, but segmentation by hand-outlining structures is often tedious and time-consuming. In this paper, methods based on analysis of statistics of image gray level are applied to segmentation of soft tissue in medical images, with the goal of making segmentation automatic or semi-automatic. The resulting segmented images, volume calculations, and 3D displays are analyzed and compared with results based on physician-drawn outlines as well as actual volume measurements

  10. Generating Animated Displays of Spacecraft Orbits

    Science.gov (United States)

    Candey, Robert M.; Chimiak, Reine A.; Harris, Bernard T.

    2005-01-01

    Tool for Interactive Plotting, Sonification, and 3D Orbit Display (TIPSOD) is a computer program for generating interactive, animated, four-dimensional (space and time) displays of spacecraft orbits. TIPSOD utilizes the programming interface of the Satellite Situation Center Web (SSCWeb) services to communicate with the SSC logic and database by use of the open protocols of the Internet. TIPSOD is implemented in Java 3D and effects an extension of the preexisting SSCWeb two-dimensional static graphical displays of orbits. Orbits can be displayed in any or all of the following seven reference systems: true-of-date (an inertial system), J2000 (another inertial system), geographic, geomagnetic, geocentric solar ecliptic, geocentric solar magnetospheric, and solar magnetic. In addition to orbits, TIPSOD computes and displays Sibeck's magnetopause and Fairfield's bow-shock surfaces. TIPSOD can be used by the scientific community as a means of projection or interpretation. It also has potential as an educational tool.

  11. Real-time analysis and display of reactor system mass inventory

    International Nuclear Information System (INIS)

    Dao, L.T.; Meachum, T.R.

    1982-01-01

    A mass inventory system (MIS) to evaluate, in real-time, the coolant distribution within the primary coolant system of the Loss-of-Fluid Test (LOFT) reactor has been developed. The computer-based system calculates and displays the coolant levels by two methods: using level measurements and performing a mass balance. The MIS is designed to provide up-to-date, intelligible information on the coolant distribution during any LOFT experiment. During LOFT experiments in which the primary coolant pumps are on, the method also provides void fraction information and the anticipated liquid level in the reactor vessel should the pumps be turned off

  12. Insulin signaling displayed a differential tissue-specific response to low-dose dihydrotestosterone in female mice.

    Science.gov (United States)

    Andrisse, Stanley; Billings, Katelyn; Xue, Ping; Wu, Sheng

    2018-04-01

    Hyperandrogenemia and hyperinsulinemia are believed to play prominent roles in polycystic ovarian syndrome (PCOS). We explored the effects of low-dose dihydrotestosterone (DHT), a model of PCOS, on insulin signaling in metabolic and reproductive tissues in a female mouse model. Insulin resistance in the energy storage tissues is associated with type 2 diabetes. Insulin signaling in the ovaries and pituitary either directly or indirectly stimulates androgen production. Energy storage and reproductive tissues were isolated and molecular assays were performed. Livers and white adipose tissue (WAT) from DHT mice displayed lower mRNA and protein expression of insulin signaling intermediates. However, ovaries and pituitaries of DHT mice exhibited higher expression levels of insulin signaling genes/proteins. Insulin-stimulated p-AKT levels were blunted in the livers and WAT of the DHT mice but increased or remained the same in the ovaries and pituitaries compared with controls. Glucose uptake decreased in liver and WAT but was unchanged in pituitary and ovary of DHT mice. Plasma membrane GLUTs were decreased in liver and WAT but increased in ovary and pituitary of DHT mice. Skeletal muscle insulin-signaling genes were not lowered in DHT mice compared with control. DHT mice did not display skeletal muscle insulin resistance. Insulin-stimulated glucose transport increased in skeletal muscles of DHT mice compared with controls. DHT mice were hyperinsulinemic. However, the differential mRNA and protein expression pattern was independent of hyperinsulinemia in cultured hepatocytes and pituitary cells. These findings demonstrate a differential effect of DHT on the insulin-signaling pathway in energy storage vs. reproductive tissues independent of hyperinsulinemia.

  13. Oil defect detection of electrowetting display

    Science.gov (United States)

    Chiang, Hou-Chi; Tsai, Yu-Hsiang; Yan, Yung-Jhe; Huang, Ting-Wei; Mang, Ou-Yang

    2015-08-01

    In recent years, transparent display is an emerging topic in display technologies. Apply in many fields just like mobile device, shopping or advertising window, and etc. Electrowetting Display (EWD) is one kind of potential transparent display technology advantages of high transmittance, fast response time, high contrast and rich color with pigment based oil system. In mass production process of Electrowetting Display, oil defects should be found by Automated Optical Inspection (AOI) detection system. It is useful in determination of panel defects for quality control. According to the research of our group, we proposed a mechanism of AOI detection system detecting the different kinds of oil defects. This mechanism can detect different kinds of oil defect caused by oil overflow or material deteriorated after oil coating or driving. We had experiment our mechanism with a 6-inch Electrowetting Display panel from ITRI, using an Epson V750 scanner with 1200 dpi resolution. Two AOI algorithms were developed, which were high speed method and high precision method. In high precision method, oil jumping or non-recovered can be detected successfully. This mechanism of AOI detection system can be used to evaluate the oil uniformity in EWD panel process. In the future, our AOI detection system can be used in quality control of panel manufacturing for mass production.

  14. Adrenocortical Production Is Associated with Higher Levels of Luteinizing Hormone in Nonobese Women with Polycystic Ovary Syndrome

    Directory of Open Access Journals (Sweden)

    Luciana Tock

    2014-01-01

    Full Text Available Objective. Insulin resistance (IR and ovarian and adrenal hyperandrogenism are a common finding in women with polycystic ovary syndrome (PCOS. The aim of the present study was to access possible differences in insulin resistance, gonadotropins, and androgens production in obese and nonobese PCOS women. Study Design. We studied 37 PCOS women (16 nonobese and 21 obese and 18 nonobese controls. Fasting glucose, insulin, androgens, and gonadotropins levels were determined. Salivary cortisol was measured basal and in the morning after dexamethasone (DEX 0.25 mg. Results. Nonobese PCOS women showed higher basal salivary cortisol and serum dehydroepiandrosterone sulfate and luteinizing hormone (LH levels than controls and obese PCOS. These hormones levels did not differ between the obese and control groups. After DEX administration no differences were found between the three groups. In PCOS women, salivary cortisol levels showed negative correlation with BMI (r=-0.52; P=0.001 and insulin (r=-0.47; P=0.003 and positive correlation with LH (r=0.40; P=0.016. Conclusion. Our results show an increased adrenocortical production in nonobese PCOS women, not related to IR and associated with a normal hypothalamic-pituitary-adrenal suppression. Higher LH levels might be involved in this event.

  15. You Be the Judge: Display.

    Science.gov (United States)

    Koeninger, Jimmy G.

    The instructional package was developed to provide the distributive education teacher-coordinator with visual materials that can be used to supplement existing textbook offerings in the area of display (visual merchandising). Designed for use with 35mm slides of retail store displays, the package allows the student to view the slides of displays…

  16. Exaggerated displays do not improve mounting success in male seaweed flies Fucellia tergina (Diptera: Anthomyiidae).

    Science.gov (United States)

    Memmott, Ruth; Briffa, Mark

    2015-11-01

    Signals of individual quality are assumed to be difficult to exaggerate, either because they are directly linked to underlying traits (indices) or because they are costly to perform (handicaps). In practise advertisement displays may consist of conventional and costly components, for instance where a morphological structure related to body size is used in visual displays. In this case, there is the potential for dishonest displays, due to the population level variance around the relationship between body size and display structures. We examine the use of wing flicking displays that we observed in situ in a strandline dwelling seaweed fly Fucellia tergina, using overall body size and the size of their eyes as underlying indicators of condition. Males displayed far more frequently than females, and were also observed to frequently mount other flies, a behaviour that was rare in females. The rate of display was greater for males that had positive residual values from relationships between wing length and body length. In other words those males with larger than expected wings for their underlying quality displayed more frequently, indicating that these displays are open to exaggeration. Males with larger than expected wings (for the size of their body or eyes), however, mounted less frequently. We suggest that small bodied males are less successful in terms of mounting, but that those small males with relatively large wings may attempt to compensate for this through increased display effort. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Method for control-room display design

    International Nuclear Information System (INIS)

    Montmayeul, R.

    1988-01-01

    This document describes a method for control-room displays design. It can be used either for isolated display to add to an existing system either for the design of a full system of operator aids. The method is a top-down design with steps of possible iteration. The emphasis is put on display design rather than on system design; system aspects are just mentioned. Advantages of using a method are described [fr

  18. Statistical Arbitrage Mining for Display Advertising

    OpenAIRE

    Zhang, Weinan; Wang, Jun

    2015-01-01

    We study and formulate arbitrage in display advertising. Real-Time Bidding (RTB) mimics stock spot exchanges and utilises computers to algorithmically buy display ads per impression via a real-time auction. Despite the new automation, the ad markets are still informationally inefficient due to the heavily fragmented marketplaces. Two display impressions with similar or identical effectiveness (e.g., measured by conversion or click-through rates for a targeted audience) may sell for quite diff...

  19. A large-scale, higher-level, molecular phylogenetic study of the insect order Lepidoptera (moths and butterflies)

    Science.gov (United States)

    Higher-level relationships within the Lepidoptera, and particularly within the species-rich subclade Ditrysia, are generally not well understood, although recent studies have yielded progress. 483 taxa spanning 115 of 124 families were sampled for 19 protein-coding nuclear genes. Their aligned nucle...

  20. Three-dimensional volumetric display by inclined-plane scanning

    Science.gov (United States)

    Miyazaki, Daisuke; Eto, Takuma; Nishimura, Yasuhiro; Matsushita, Kenji

    2003-05-01

    A volumetric display system based on three-dimensional (3-D) scanning that uses an inclined two-dimensional (2-D) image is described. In the volumetric display system a 2-D display unit is placed obliquely in an imaging system into which a rotating mirror is inserted. When the mirror is rotated, the inclined 2-D image is moved laterally. A locus of the moving image can be observed by persistence of vision as a result of the high-speed rotation of the mirror. Inclined cross-sectional images of an object are displayed on the display unit in accordance with the position of the image plane to observe a 3-D image of the object by persistence of vision. Three-dimensional images formed by this display system satisfy all the criteria for stereoscopic vision. We constructed the volumetric display systems using a galvanometer mirror and a vector-scan display unit. In addition, we constructed a real-time 3-D measurement system based on a light section method. Measured 3-D images can be reconstructed in the 3-D display system in real time.

  1. Higher weight, lower education: a longitudinal association between adolescents' body mass index and their subsequent educational achievement level?

    Science.gov (United States)

    Larsen, Junilla K; Kleinjan, Marloes; Engels, Rutger C M E; Fisher, Jennifer O; Hermans, Roel C J

    2014-12-01

    The purpose of this study was to examine the association between adolescents' body mass index (BMI) z-scores and their subsequent level of schooling, extending previous longitudinal research by using objectively measured weight and height data. A longitudinal study with 3 study waves (1-year intervals) involving 1248 Dutch adolescents (49% girls; mean age = 13.7 years) at schools providing different educational levels was used to determine adolescents who moved and did not move to a lower educational level in the first year, or in the second year, and to examine whether this movement could be predicted by BMI z-scores (zBMI), after controlling for a large range of potential confounding factors. A total of 1164 Dutch adolescents continued in the same level of education, whereas 84 adolescents moved to a lower educational level (43 moved in the first and 41 in the second year). A higher zBMI significantly increased the risk of a general transition to a lower educational level, and of a transition in the first year, but not in the second year, after controlling for potential demographic, behavioral, and psychological confounds. Findings suggest that a higher zBMI during adolescence immediately lowers educational achievement level during general secondary education. © 2014, American School Health Association.

  2. Displays: Entering a New Dimension

    Science.gov (United States)

    Starkman, Neal

    2007-01-01

    As display technologies prepare to welcome 3-D, the 21st-century classroom will soon bear little resemblance to anything students and teachers have ever seen. In this article, the author presents the latest innovations in the world of digital display technology. These include: (1) Touchlight, an interactive touch screen program that takes a normal…

  3. Irradiation from video display terminals

    International Nuclear Information System (INIS)

    Backe, S.; Hannevik, M.

    1987-01-01

    Video display terminals (VDT's) are in common use by computer operators. In the last years this group of workers has expressed growing concern about their work environment and possible hazardious effects in connection with radiation emission from VDT's. Radiation types and levels of emission and possible biological effects have been the subject of research activity in Norway and in other countries. This report summarizes the various radiation types and their levels of emission from VDT's. An overview of recent epidemiological studies and animal experiments, and the conclusions given by the research groups are also presented. The conclusions drawn in this report based on the current knowledge are: Radiation, other than low frequency pulsed magnetic fields, have low and negligible emission levels and will not represent any health hazard to VDT-operator or to the foetus of pregnant operators. The biological effects of low frequency pulsed mangetic fields have been the subject of epidemiological studies and animal experiments. Epidemiological studies carried out in Canada, Finland, Sweden and Norway gave no support for any correlation between pregnancy complications and operation of VDT's. From animal experiments it has so far been impossible to assert an effect on pregnancy outcome from low frequency pulsed magnetic fields

  4. Crystal ball single event display

    International Nuclear Information System (INIS)

    Grosnick, D.; Gibson, A.; Allgower, C.; Alyea, J.; Argonne National Lab., IL

    1997-01-01

    The Single Event Display (SED) is a routine that is designed to provide information graphically about a triggered event within the Crystal Ball. The SED is written entirely in FORTRAN and uses the CERN-based HICZ graphing package. The primary display shows the amount of energy deposited in each of the NaI crystals on a Mercator-like projection of the crystals. Ten different shades and colors correspond to varying amounts of energy deposited within a crystal. Information about energy clusters is displayed on the crystal map by outlining in red the thirteen (or twelve) crystals contained within a cluster and assigning each cluster a number. Additional information about energy clusters is provided in a series of boxes containing useful data about the energy distribution among the crystals within the cluster. Other information shown on the event display include the event trigger type and data about π o 's and η's formed from pairs of clusters as found by the analyzer. A description of the major features is given, along with some information on how to install the SED into the analyzer

  5. Mucosal vaccination by adenoviruses displaying reovirus sigma 1

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, Eric A. [Department of Internal Medicine, Division of Infectious Diseases, Translational Immunovirology and Biodefense Program, Mayo Clinic, Rochester, MN 55902 (United States); Camacho, Zenaido T. [Department of Cell Biology, Department of Natural Sciences, Western New Mexico University, Silver City, NM 88062 (United States); Hillestad, Matthew L. [Nephrology Training Program, Mayo Clinic, Rochester, MN 55902 (United States); Crosby, Catherine M.; Turner, Mallory A.; Guenzel, Adam J.; Fadel, Hind J. [Virology and Gene Therapy Graduate Program, Mayo Clinic, Rochester, MN 55902 (United States); Mercier, George T. [Department of Physics, University of Houston, Houston, TX 77004 (United States); Barry, Michael A., E-mail: mab@mayo.edu [Department of Internal Medicine, Division of Infectious Diseases, Translational Immunovirology and Biodefense Program, Mayo Clinic, Rochester, MN 55902 (United States); Department of Immunology and Department of Molecular Medicine, Mayo Clinic, Rochester, MN 55902 (United States)

    2015-08-15

    We developed adenovirus serotype 5 (Ad5) vectors displaying the sigma 1 protein from reovirus as mucosal vaccines. Ad5-sigma retargets to JAM-1 and sialic acid, but has 40-fold reduced gene delivery when compared to Ad5. While weaker at transduction, Ad5-sigma generates stronger T cell responses than Ad5 when used for mucosal immunization. In this work, new Ad5-fiber-sigma vectors were generated by varying the number of fiber β-spiral shaft repeats (R) between the fiber tail and sigma. Increasing chimera length led to decreasing insertion of these proteinsAd5 virions. Ad-R3 and R14 vectors effectively targeted JAM-1 in vitro while R20 did not. When wereused to immunize mice by the intranasal route, Ad5-R3-sigma produced higher serum and vaginal antibody responses than Ad5. These data suggest optimized Ad-sigma vectors may be useful vectors for mucosal vaccination. - Highlights: • Constructed adenoviruses (Ads) displaying different reovirus sigma 1 fusion proteins. • Progressively longer chimeras were more poorly encapsidated onto Ad virions. • Ad5-R3-sigma mediated better systemic and mucosal immune responses than Ad5.

  6. Mucosal vaccination by adenoviruses displaying reovirus sigma 1

    International Nuclear Information System (INIS)

    Weaver, Eric A.; Camacho, Zenaido T.; Hillestad, Matthew L.; Crosby, Catherine M.; Turner, Mallory A.; Guenzel, Adam J.; Fadel, Hind J.; Mercier, George T.; Barry, Michael A.

    2015-01-01

    We developed adenovirus serotype 5 (Ad5) vectors displaying the sigma 1 protein from reovirus as mucosal vaccines. Ad5-sigma retargets to JAM-1 and sialic acid, but has 40-fold reduced gene delivery when compared to Ad5. While weaker at transduction, Ad5-sigma generates stronger T cell responses than Ad5 when used for mucosal immunization. In this work, new Ad5-fiber-sigma vectors were generated by varying the number of fiber β-spiral shaft repeats (R) between the fiber tail and sigma. Increasing chimera length led to decreasing insertion of these proteinsAd5 virions. Ad-R3 and R14 vectors effectively targeted JAM-1 in vitro while R20 did not. When wereused to immunize mice by the intranasal route, Ad5-R3-sigma produced higher serum and vaginal antibody responses than Ad5. These data suggest optimized Ad-sigma vectors may be useful vectors for mucosal vaccination. - Highlights: • Constructed adenoviruses (Ads) displaying different reovirus sigma 1 fusion proteins. • Progressively longer chimeras were more poorly encapsidated onto Ad virions. • Ad5-R3-sigma mediated better systemic and mucosal immune responses than Ad5

  7. Design of the task-based display prototype and the first user-test

    International Nuclear Information System (INIS)

    Svengren, Haakan; Strand, Stine

    2005-09-01

    This report provides a description of the Task-based displays prototype for BWRs, and documents the results of the first user-test. Three different kinds of Task-based displays were designed: 1) displays for performing first checks and obtaining overview in emergency situations, 2) displays for performing emergency procedures, and 3) displays that facilitate understanding of the process and logic. The procedures included an expert-help function to support the operators in performing the procedures. The design was only implemented on the reactor side of the plant. The user-test was conducted using the HAMBO simulator in HAMMLAB. 6 crews from Forsmark 3 and Oskarshamn 3 participated in the test. The crews participated in 4 scenarios, which all were considered as highly complex scenarios that included actuation of several reactor protection signals. The data collection techniques (questionnaires and interviews) intended to cover usability-related issues and mainly involved the reactor operators. The results demonstrated that the Task-based design approach was very well received by the operators, and that the work initiated by the design of this first prototype should be continued. The operators generally found the procedure-implementation and the displays useful and easy to understand. They considered the amount of information contained in the procedures and the displays as good, and associated with low levels of frustration. The expert-help provided in the current test was very premature. This resulted in somewhat poorer usability ratings compared to the procedures and the displays. However, the operators explicitly stated the usefulness of providing expert-help in the combination with computerized procedures. The operators rated the computer-based procedures as slightly easier, less time-consuming, and slightly less mentally demanding than paper-based procedures. All the operators considered navigation within and between the procedures as easy, although some

  8. Touch sensitive electrorheological fluid based tactile display

    Science.gov (United States)

    Liu, Yanju; Davidson, Rob; Taylor, Paul

    2005-12-01

    A tactile display is programmable device whose controlled surface is intended to be investigated by human touch. It has a great number of potential applications in the field of virtual reality and elsewhere. In this research, a 5 × 5 tactile display array including electrorheological (ER) fluid has been developed and investigated. Force responses of the tactile display array have been measured while a probe was moved across the upper surface. The purpose of this was to simulate the action of touch performed by human finger. Experimental results show that the sensed surface information could be controlled effectively by adjusting the voltage activation pattern imposed on the tactels. The performance of the tactile display is durable and repeatable. The touch sensitivity of this ER fluid based tactile display array has also been investigated in this research. The results show that it is possible to sense the touching force normal to the display's surface by monitoring the change of current passing through the ER fluid. These encouraging results are helpful for constructing a new type of tactile display based on ER fluid which can act as both sensor and actuator at the same time.

  9. Association between sarcopenia and higher-level functional capacity in daily living in community-dwelling elderly subjects in Japan.

    Science.gov (United States)

    Tanimoto, Yoshimi; Watanabe, Misuzu; Sun, Wei; Sugiura, Yumiko; Tsuda, Yuko; Kimura, Motoshi; Hayashida, Itsushi; Kusabiraki, Toshiyuki; Kono, Koichi

    2012-01-01

    This study aimed to determine the association between sarcopenia, defined by muscle mass, muscle strength, and physical performance, and higher-level functional capacity in community-dwelling Japanese elderly people. Subjects were 1158 elderly, community-dwelling Japanese people aged 65 or older. We used bioelectrical impedance analysis to measure muscle mass, grip strength to measure muscle strength, and usual walking speed to measure physical performance. Sarcopenia was characterized by low muscle mass, plus low muscle strength or low physical performance. Subjects without low muscle mass, low muscle strength, and low physical performance were classified as "normal." Examination of higher-level functional capacity was performed using the Tokyo Metropolitan Institute of Gerontology Index of Competence (TMIG-IC). The TMIG-IC is a 13-item questionnaire completed by the subject; it contains five questions on self-maintenance and four questions each on intellectual activity and social role. Sarcopenia was identified in 11.3% and 10.7% of men and women, respectively. The percentage of disability for instrumental activities of daily living (IADL) was 39.0% in men with sarcopenia and 30.6% in women with sarcopenia. After adjustment for age, in men, sarcopenia was significantly associated with IADL disability compared with intermediate and normal subjects. In women, sarcopenia was significantly associated with every subscale of the TMIG-IC disability compared with intermediate and normal subjects. This study revealed that sarcopenia, defined by muscle mass, muscle strength, and physical performance, had a significant association with disability in higher-level functional capacity in elderly Japanese subjects. Interventions to prevent sarcopenia may prevent higher-level functional disability among elderly people. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Acquisition of L2 Japanese Geminates: Training with Waveform Displays

    Science.gov (United States)

    Motohashi-Saigo, Miki; Hardison, Debra M.

    2009-01-01

    The value of waveform displays as visual feedback was explored in a training study involving perception and production of L2 Japanese by beginning-level L1 English learners. A pretest-posttest design compared auditory-visual (AV) and auditory-only (A-only) Web-based training. Stimuli were singleton and geminate /t,k,s/ followed by /a,u/ in two…

  11. Biomechanics of the Peacock's Display: How Feather Structure and Resonance Influence Multimodal Signaling.

    Directory of Open Access Journals (Sweden)

    Roslyn Dakin

    Full Text Available Courtship displays may serve as signals of the quality of motor performance, but little is known about the underlying biomechanics that determines both their signal content and costs. Peacocks (Pavo cristatus perform a complex, multimodal "train-rattling" display in which they court females by vibrating the iridescent feathers in their elaborate train ornament. Here we study how feather biomechanics influences the performance of this display using a combination of field recordings and laboratory experiments. Using high-speed video, we find that train-rattling peacocks stridulate their tail feathers against the train at 25.6 Hz, on average, generating a broadband, pulsating mechanical sound at that frequency. Laboratory measurements demonstrate that arrays of peacock tail and train feathers have a broad resonant peak in their vibrational spectra at the range of frequencies used for train-rattling during the display, and the motion of feathers is just as expected for feathers shaking near resonance. This indicates that peacocks are able to drive feather vibrations energetically efficiently over a relatively broad range of frequencies, enabling them to modulate the feather vibration frequency of their displays. Using our field data, we show that peacocks with longer trains use slightly higher vibration frequencies on average, even though longer train feathers are heavier and have lower resonant frequencies. Based on these results, we propose hypotheses for future studies of the function and energetics of this display that ask why its dynamic elements might attract and maintain female attention. Finally, we demonstrate how the mechanical structure of the train feathers affects the peacock's visual display by allowing the colorful iridescent eyespots-which strongly influence female mate choice-to remain nearly stationary against a dynamic iridescent background.

  12. XY model with higher-order exchange.

    Science.gov (United States)

    Žukovič, Milan; Kalagov, Georgii

    2017-08-01

    An XY model, generalized by inclusion of up to an infinite number of higher-order pairwise interactions with an exponentially decreasing strength, is studied by spin-wave theory and Monte Carlo simulations. At low temperatures the model displays a quasi-long-range-order phase characterized by an algebraically decaying correlation function with the exponent η=T/[2πJ(p,α)], nonlinearly dependent on the parameters p and α that control the number of the higher-order terms and the decay rate of their intensity, respectively. At higher temperatures the system shows a crossover from the continuous Berezinskii-Kosterlitz-Thouless to the first-order transition for the parameter values corresponding to a highly nonlinear shape of the potential well. The role of topological excitations (vortices) in changing the nature of the transition is discussed.

  13. Volumetric, dashboard-mounted augmented display

    Science.gov (United States)

    Kessler, David; Grabowski, Christopher

    2017-11-01

    The optical design of a compact volumetric display for drivers is presented. The system displays a true volume image with realistic physical depth cues, such as focal accommodation, parallax and convergence. A large eyebox is achieved with a pupil expander. The windshield is used as the augmented reality combiner. A freeform windshield corrector is placed at the dashboard.

  14. Flexible Bistable Cholesteric Reflective Displays

    Science.gov (United States)

    Yang, Deng-Ke

    2006-03-01

    Cholesteric liquid crystals (ChLCs) exhibit two stable states at zero field condition-the reflecting planar state and the nonreflecting focal conic state. ChLCs are an excellent candidate for inexpensive and rugged electronic books and papers. This paper will review the display cell structure,materials and drive schemes for flexible bistable cholesteric (Ch) reflective displays.

  15. Reading Comprehension, Working Memory and Higher-Level Language Skills in Children with SLI and/or Dyslexia

    Science.gov (United States)

    Wong, Anita M.-Y.; Ho, Connie S.-H.; Au, Terry K.-F.; McBride, Catherine; Ng, Ashley K.-H.; Yip, Lesley P.-W.; Lam, Catherine C.-C.

    2017-01-01

    This study examined (1) whether working memory and higher-level languages skills--inferencing and comprehension monitoring--accounted for individual differences among Chinese children in Chinese reading comprehension, after controlling for age, Chinese word reading and oral language skills, and (2) whether children with specific language…

  16. Higher Serum Levels of Free ĸ plus λ Immunoglobulin Light Chains Ameliorate Survival of Hemodialysis Patients

    DEFF Research Database (Denmark)

    Thilo, Florian; Caspari, Christina; Scholze, Alexandra

    2011-01-01

    Background/Aims: Impaired immune function is common in patients with chronic renal failure. Now, we determined whether serum levels of free immunoglobulin light chains predict mortality in patients with chronic kidney disease stage 5 on hemodialysis. Methods: We performed a prospective cohort study...... of 160 hemodialysis patients with a median follow-up of 15 months (interquartile range, 3-44 months). Serum levels of free κ and λ immunoglobulin light chains were measured at the start of the study. The primary end point was mortality from any cause. Results: In survivors, median serum levels of free κ...... plus λ immunoglobulin light chains were significantly higher compared with nonsurvivors (p light chains above the median compared with patients with serum levels below the median of 210 mg...

  17. “It Looks Like an Adult Sweetie Shop”: Point-of-Sale Tobacco Display Exposure and Brand Awareness in Scottish Secondary School Students

    Science.gov (United States)

    van der Sluijs, Winfried; Miller, Martine; MacGregor, Andy; Sharp, Clare; Amos, Amanda; Best, Catherine; Stead, Martine; Eadie, Douglas; Pearce, Jamie; Frank, John; Haw, Sally

    2016-01-01

    Introduction: As further restrictions have been placed on tobacco advertising and promotions, point-of-sale (PoS) displays of cigarettes in shops have become an increasingly important source of young people’s exposure to tobacco products. This study explored the relationship between PoS displays of cigarettes and brand awareness among secondary school students in Scotland. Methods: Cross-sectional school surveys (n = 1406) and focus groups (n = 86) were conducted with S2 (13–14 years) and S4 (15–16 years) students in four schools of differing socioeconomic status in 2013, prior to the PoS display ban in large shops. Adjusted negative binomial regression analysis examined associations between brand awareness and exposure variables (visiting tobacco retailers, noticing displays of tobacco products). Results: Students visiting small shops more frequently (relative rate ratio [RRR] 1.19, 95% confidence interval [CI] 1.01–1.41) and those who noticed cigarette displays in small shops (RRR 1.24, 95% CI 1.03–1.51) and large supermarkets (RRR 1.15, 95% CI 1.01–1.30) had higher brand awareness. The focus groups supported these findings. Participants described PoS tobacco displays as being eye-catching, colorful and potentially attractive to young people. Conclusions: This mixed-methods study showed that higher cigarette brand awareness was significantly associated with regularly visiting small shops and noticing PoS displays in small and large shops, even when students’ smoking status, smoking in their social networks, leisure activities, and demographics were included as confounding variables. This highlights the importance of PoS displays of tobacco products in increasing brand awareness, which is known to increase youth smoking susceptibility, and thus the importance of implementing PoS display bans in all shops. Implications: As increasing restrictions have been placed on tobacco promotion in many countries, PoS displays of cigarettes in shops have become

  18. Multimethods approach to safety-parameter-display evaluation

    International Nuclear Information System (INIS)

    Banks, W.W.; Blackman, H.S.; Gertman, D.I.; Petersen, R.J.

    1982-01-01

    The Human Factors Engineering Office of EG and G Idaho performed this NRC-funded study to assist the NRC in objectively assessing licensee-developed safety parameter display (SPD) formats and designs. The purpose of this study was to quantitatively measure the degree to which a tachistoscopic method of display evaluation would correlate with the results of a multidimensional rating approach to display evaluation. Results of the following three experiments will be presented; (a) tachistoscopic, (b) multidimensional rating scale, and (c) the combined results of a and b. The test material for all experiments consisted of three multivariate data display formats all under development as SPDs for reactor control rooms presenting safety parameter display data at the loss-of-fluid test (LOFT) facility. The three display formats studied were stars, deviation bar graphs, and meters. Eighteen adult volunteers were used as subjects. All were currently qualified reactor operators from the LOFT reactor plant, with a mean of 9.4 years reactor operating experience

  19. Antecedents and consequences of emotional display rule perceptions.

    Science.gov (United States)

    Diefendorff, James M; Richard, Erin M

    2003-04-01

    Central to all theories of emotional labor is the idea that individuals follow emotional display rules that specify the appropriate expression of emotions on the job. This investigation examined antecedents and consequences of emotional display rule perceptions. Full-time working adults (N = 152) from a variety of occupations provided self-report data, and supervisors and coworkers completed measures pertaining to the focal employees. Results using structural equation modeling revealed that job-based interpersonal requirements, supervisor display rule perceptions, and employee extraversion and neuroticism were predictive of employee display rule perceptions. Employee display rule perceptions, in turn, were related to self-reported job satisfaction and coworker ratings of employees' emotional displays on the job. Finally, neuroticism had direct negative relationships with job satisfaction and coworker ratings of employees' emotional displays.

  20. New portable FELIX 3D display

    Science.gov (United States)

    Langhans, Knut; Bezecny, Daniel; Homann, Dennis; Bahr, Detlef; Vogt, Carsten; Blohm, Christian; Scharschmidt, Karl-Heinz

    1998-04-01

    An improved generation of our 'FELIX 3D Display' is presented. This system is compact, light, modular and easy to transport. The created volumetric images consist of many voxels, which are generated in a half-sphere display volume. In that way a spatial object can be displayed occupying a physical space with height, width and depth. The new FELIX generation uses a screen rotating with 20 revolutions per second. This target screen is mounted by an easy to change mechanism making it possible to use appropriate screens for the specific purpose of the display. An acousto-optic deflection unit with an integrated small diode pumped laser draws the images on the spinning screen. Images can consist of up to 10,000 voxels at a refresh rate of 20 Hz. Currently two different hardware systems are investigated. The first one is based on a standard PCMCIA digital/analog converter card as an interface and is controlled by a notebook. The developed software is provided with a graphical user interface enabling several animation features. The second, new prototype is designed to display images created by standard CAD applications. It includes the development of a new high speed hardware interface suitable for state-of-the- art fast and high resolution scanning devices, which require high data rates. A true 3D volume display as described will complement the broad range of 3D visualization tools, such as volume rendering packages, stereoscopic and virtual reality techniques, which have become widely available in recent years. Potential applications for the FELIX 3D display include imaging in the field so fair traffic control, medical imaging, computer aided design, science as well as entertainment.

  1. Visual ergonomic aspects of glare on computer displays: glossy screens and angular dependence

    Science.gov (United States)

    Brunnström, Kjell; Andrén, Börje; Konstantinides, Zacharias; Nordström, Lukas

    2007-02-01

    Recently flat panel computer displays and notebook computer are designed with a so called glare panel i.e. highly glossy screens, have emerged on the market. The shiny look of the display appeals to the costumers, also there are arguments that the contrast, colour saturation etc improves by using a glare panel. LCD displays suffer often from angular dependent picture quality. This has been even more pronounced by the introduction of Prism Light Guide plates into displays for notebook computers. The TCO label is the leading labelling system for computer displays. Currently about 50% of all computer displays on the market are certified according to the TCO requirements. The requirements are periodically updated to keep up with the technical development and the latest research in e.g. visual ergonomics. The gloss level of the screen and the angular dependence has recently been investigated by conducting user studies. A study of the effect of highly glossy screens compared to matt screens has been performed. The results show a slight advantage for the glossy screen when no disturbing reflexes are present, however the difference was not statistically significant. When disturbing reflexes are present the advantage is changed into a larger disadvantage and this difference is statistically significant. Another study of angular dependence has also been performed. The results indicates a linear relationship between the picture quality and the centre luminance of the screen.

  2. Evaluation of tactual displays for flight control

    Science.gov (United States)

    Levison, W. H.; Tanner, R. B.; Triggs, T. J.

    1973-01-01

    Manual tracking experiments were conducted to determine the suitability of tactual displays for presenting flight-control information in multitask situations. Although tracking error scores are considerably greater than scores obtained with a continuous visual display, preliminary results indicate that inter-task interference effects are substantially less with the tactual display in situations that impose high visual scanning workloads. The single-task performance degradation found with the tactual display appears to be a result of the coding scheme rather than the use of the tactual sensory mode per se. Analysis with the state-variable pilot/vehicle model shows that reliable predictions of tracking errors can be obtained for wide-band tracking systems once the pilot-related model parameters have been adjusted to reflect the pilot-display interaction.

  3. Real time speech formant analyzer and display

    Science.gov (United States)

    Holland, George E.; Struve, Walter S.; Homer, John F.

    1987-01-01

    A speech analyzer for interpretation of sound includes a sound input which converts the sound into a signal representing the sound. The signal is passed through a plurality of frequency pass filters to derive a plurality of frequency formants. These formants are converted to voltage signals by frequency-to-voltage converters and then are prepared for visual display in continuous real time. Parameters from the inputted sound are also derived and displayed. The display may then be interpreted by the user. The preferred embodiment includes a microprocessor which is interfaced with a television set for displaying of the sound formants. The microprocessor software enables the sound analyzer to present a variety of display modes for interpretive and therapeutic used by the user.

  4. The future of 2D metrology for display manufacturing

    Science.gov (United States)

    Sandstrom, Tor; Wahlsten, Mikael; Park, Youngjin

    2016-10-01

    The race to 800 PPI and higher in mobile devices and the transition to OLED displays are driving a dramatic development of mask quality: resolution, CDU, registration, and complexity. 2D metrology for large area masks is necessary and must follow the roadmap. Driving forces in the market place point to continued development of even more dense displays. State-of-the-art metrology has proven itself capable of overlay below 40 nm and registration below 65 nm for G6 masks. Future developments include incoming and recurrent measurements of pellicalized masks at the panel maker's factory site. Standardization of coordinate systems across supplier networks is feasible. This will enable better yield and production economy for both mask and panel maker. Better distortion correction methods will give better registration on the panels and relax the flatness requirements of the mask blanks. If panels are measured together with masks and the results are used to characterize the aligners, further quality and yield improvements are possible. Possible future developments include in-cell metrology and integration with other instruments in the same platform.

  5. Transparent 3D display for augmented reality

    Science.gov (United States)

    Lee, Byoungho; Hong, Jisoo

    2012-11-01

    Two types of transparent three-dimensional display systems applicable for the augmented reality are demonstrated. One of them is a head-mounted-display-type implementation which utilizes the principle of the system adopting the concave floating lens to the virtual mode integral imaging. Such configuration has an advantage in that the threedimensional image can be displayed at sufficiently far distance resolving the accommodation conflict with the real world scene. Incorporating the convex half mirror, which shows a partial transparency, instead of the concave floating lens, makes it possible to implement the transparent three-dimensional display system. The other type is the projection-type implementation, which is more appropriate for the general use than the head-mounted-display-type implementation. Its imaging principle is based on the well-known reflection-type integral imaging. We realize the feature of transparent display by imposing the partial transparency to the array of concave mirror which is used for the screen of reflection-type integral imaging. Two types of configurations, relying on incoherent and coherent light sources, are both possible. For the incoherent configuration, we introduce the concave half mirror array, whereas the coherent one adopts the holographic optical element which replicates the functionality of the lenslet array. Though the projection-type implementation is beneficial than the head-mounted-display in principle, the present status of the technical advance of the spatial light modulator still does not provide the satisfactory visual quality of the displayed three-dimensional image. Hence we expect that the head-mounted-display-type and projection-type implementations will come up in the market in sequence.

  6. New developments in flexible cholesteric liquid crystal displays

    Science.gov (United States)

    Schneider, Tod; Davis, Donald J.; Franklin, Sean; Venkataraman, Nithya; McDaniel, Diaz; Nicholson, Forrest; Montbach, Erica; Khan, Asad; Doane, J. William

    2007-02-01

    Flexible Cholesteric liquid crystal displays have been rapidly maturing into a strong contender in the flexible display market. Encapsulation of the Cholesteric liquid crystal permits the use of flexible plastic substrates and roll-to-roll production. Recent advances include ultra-thin displays, laser-cut segmented displays of variable geometry, and smart card applications. Exciting technologies such as simultaneous laser-edge sealing and singulation enable high volume production, excellent quality control and non-traditional display geometries and formats.

  7. Educational Testing of an Auditory Display of Mars Gamma Ray Spectrometer Data

    Science.gov (United States)

    Keller, J. M.; Pompea, S. M.; Prather, E. E.; Slater, T. F.; Boynton, W. V.; Enos, H. L.; Quinn, M.

    2003-12-01

    A unique, alternative educational and public outreach product was created to investigate the use and effectiveness of auditory displays in science education. The product, which allows students to both visualize and hear seasonal variations in data detected by the Gamma Ray Spectrometer (GRS) aboard the Mars Odyssey spacecraft, consists of an animation of false-color maps of hydrogen concentrations on Mars along with a musical presentation, or sonification, of the same data. Learners can access this data using the visual false-color animation, the auditory false-pitch sonification, or both. Central to the development of this product is the question of its educational effectiveness and implementation. During the spring 2003 semester, three sections of an introductory astronomy course, each with ˜100 non-science undergraduates, were presented with one of three different exposures to GRS hydrogen data: one auditory, one visual, and one both auditory and visual. Student achievement data was collected through use of multiple-choice and open-ended surveys administered before, immediately following, and three and six weeks following the experiment. It was found that the three student groups performed equally well in their ability to perceive and interpret the data presented. Additionally, student groups exposed to the auditory display reported a higher interest and engagement level than the student group exposed to the visual data alone. Based upon this preliminary testing,we have made improvements to both the educational product and our evaluation protocol. This fall, we will conduct further testing with ˜100 additional students, half receiving auditory data and half receiving visual data, and we will conduct interviews with individual students as they interface with the auditory display. Through this process, we hope to further assess both learning and engagement gains associated with alternative and multi-modal representations of scientific data that extend beyond

  8. Soccer Offside Judgments in Laypersons with Different Types of Static Displays.

    Directory of Open Access Journals (Sweden)

    Peter Wühr

    Full Text Available Four experiments investigated offside decisions in laypersons with different types of static displays. Previous research neglected this group although the majority of assistant referees in soccer games at the amateur level are laypersons. The aims of our research were (a to investigate the spatial resolution in laypersons' perception of offside situations, (b to search for biases in laypersons' offside judgments, and (c to develop useful displays for future research. The displays showed the moment when a midfielder passes the ball to a forward moving in the vicinity of a defender. We varied the spatial location of the forward around the defender in eleven steps and participants made their offside decision by pressing a key. Across experiments, displays varied in abstractness (simple shapes, clipart figures, photographs. There were two major findings. Firstly, both accuracy and speed of offside judgments deteriorated when the spatial distance between forward and defender decreased, approaching guessing rate at the smallest distances. Secondly, participants showed a consistent bias in favor of the non-offside response, in contrast to most studies on professional assistant referees. In sum, the results highlight the limited spatial resolution of the visual system and underscore the role of response bias in offside-judgment tasks.

  9. Large Display Interaction via Multiple Acceleration Curves and Multifinger Pointer Control

    Directory of Open Access Journals (Sweden)

    Andrey Esakia

    2014-01-01

    Full Text Available Large high-resolution displays combine high pixel density with ample physical dimensions. The combination of these factors creates a multiscale workspace where interactive targeting of on-screen objects requires both high speed for distant targets and high accuracy for small targets. Modern operating systems support implicit dynamic control-display gain adjustment (i.e., a pointer acceleration curve that helps to maintain both speed and accuracy. However, large high-resolution displays require a broader range of control-display gains than a single acceleration curve can usably enable. Some interaction techniques attempt to solve the problem by utilizing multiple explicit modes of interaction, where different modes provide different levels of pointer precision. Here, we investigate the alternative hypothesis of using a single mode of interaction for continuous pointing that enables both (1 standard implicit granularity control via an acceleration curve and (2 explicit switching between multiple acceleration curves in an efficient and dynamic way. We evaluate a sample solution that augments standard touchpad accelerated pointer manipulation with multitouch capability, where the choice of acceleration curve dynamically changes depending on the number of fingers in contact with the touchpad. Specifically, users can dynamically switch among three different acceleration curves by using one, two, or three fingers on the touchpad.

  10. Cross-Age Mentoring to Support A-Level Pupils' Transition into Higher Education and Undergraduate Students' Employability

    Science.gov (United States)

    James, Alana I.

    2014-01-01

    Two challenges identified for psychology higher education are supporting entry students' transition, and supporting graduates' transition into employment. The evaluation of the first phase of a cross-age mentoring action research project targeting these issues is presented; eight psychology undergraduates mentored 20 A-level psychology pupils in…

  11. 27 CFR 6.35 - Renting display space.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Renting display space. 6.35 Section 6.35 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU... Renting display space. The renting of display space by an industry member at a retail establishment...

  12. 27 CFR 6.56 - Renting display space.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Renting display space. 6.56 Section 6.56 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU... Distribution Service § 6.56 Renting display space. A promotion whereby an industry member rents display space...

  13. 14 CFR 255.4 - Display of information.

    Science.gov (United States)

    2010-01-01

    ... REGULATIONS AIRLINE COMPUTER RESERVATIONS SYSTEMS § 255.4 Display of information. (a) All systems shall provide at least one integrated display that includes the schedules, fares, rules, and availability of all... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Display of information. 255.4 Section 255.4...

  14. A higher score on the Aging Males' Symptoms scale is associated with insulin resistance in middle-aged men.

    Science.gov (United States)

    Hamanoue, Nobuya; Tanabe, Makito; Tanaka, Tomoko; Akehi, Yuko; Murakami, Junji; Nomiyama, Takashi; Yanase, Toshihiko

    2017-05-30

    An age-associated androgen decrease and its pathological conditions are defined as late-onset hypogonadism (LOH). Among the various symptoms associated with LOH, a visceral fat increase is strongly associated with relatively low levels of testosterone. However, few studies have investigated the relationship between the Aging Males' Symptoms (AMS) scores and metabolic abnormalities. Thus, we aimed to clarify this relationship by investigating the relationship between AMS scores and various markers in blood. During routine health examinations in 241 middle-aged males (52.7±7.5 years of age, mean±SD), 150 males (62.2%) displayed higher AMS values than normal. No statistical association was observed between total AMS scores and any testosterone value. All mental, physical and sexual AMS subscales were significantly positively correlated with insulin levels and HOMA-IR. Only sexual subscale scores were significantly inversely associated with free or bioavailable testosterone level. Males with insulin resistance (HOMA-IR≥2.5) demonstrated significantly higher AMS scores than those with normal insulin sensitivity (HOMA-IRinsulin and HOMA-IR values. Interestingly, univariate and multivariate analyses revealed that HOMA-IR≥2.5 was a significant predictor for detection of moderately severe AMS values (AMS≥37), whereas AMS≥37 was not a predictor of metabolic syndrome by International Diabetes Federation (IDF) criterion. In conclusion, almost 60% of healthy male subjects displayed abnormal AMS scores. AMS values were not associated with testosterone values but rather were related to insulin resistance, particularly in subjects with moderately severe AMS values. Insulin resistance-related general unwellness might be reflected by AMS values.

  15. Fusion methodologies in crisis management higher level fusion and decision making

    CERN Document Server

    Scott, Peter

    2016-01-01

    This book emphasizes a contemporary view on the role of higher level fusion in designing crisis management systems. It provides the formal foundations, architecture, and implementation strategies required for building dynamic current and future situational pictures. It goes on to discuss the state-of-the-art computational approaches to designing such processes and their inherent challenges. This book integrates recent advances in decision theory with those in fusion methodology to define an end-to-end framework for decision support in crisis management. The text discusses modern fusion and decision support methods for dealing with heterogeneous and often unreliable, low fidelity, contradictory, and redundant data and information, as well as rare, unknown, unconventional or even unimaginable critical situations. The book also examines the role of context in situation management, cognitive aspects of decision making and situation management, approaches to domain representation, visualization, as well as the rol...

  16. Effects of Display Gamma and Illuminant on the Appearance of Colours Viewed on LCD Monitors

    Directory of Open Access Journals (Sweden)

    Dragoljub Novakovic

    2009-11-01

    Full Text Available The CIECAM02 colour appearance model was developed to allow prediction of accurate colour appearance under various viewing conditions. In this study, a software module, based on mathematical transformations of the CIECAM02 model, was designed and implemented. Unlike the previous software modules, which were allowing use of only a limited choice of common standardized icc display profiles, the developed module also allows the use of optimized profiles created by the user. This paper presents prediction of the appearance of test images with assigned different display profiles after changing illuminant. The two used optimized profiles, created by software characterization of specific lcd display, have a different display gamma value (1.8 and 2.2.  It is observed that, after changing the initial cie D50 to a higher colour temperature illuminant (D65,  the colours of  images will be shifted to the blue hues, and, in the case of illuminant temperature less than D50 (A and F11,  to yellow hues. It is also observed that the intensity of colour shifts in the simulated images with associated profiles which have different gamma value will be significantly different, which implies that the icc display profile and display gamma value have the great impact on the prediction of the accurate colour appearance under various viewing conditions.

  17. Tooth display and lip position during spontaneous and posed smiling in adults.

    Science.gov (United States)

    Van Der Geld, Pieter; Oosterveld, Paul; Berge, Stefaan J; Kuijpers-Jagtman, Anne M

    2008-08-01

    To analyze differences in tooth display, lip-line height, and smile width between the posed smiling record, traditionally produced for orthodontic diagnosis, and the spontaneous (Duchenne) smile of joy. The faces of 122 male participants were each filmed during spontaneous and posed smiling. Spontaneous smiles were elicited through the participants watching a comical movie. Maxillary and mandibular lip-line heights, tooth display, and smile width were measured using a digital videographic method for smile analysis. Paired sample t-tests were used to compare measurements of posed and spontaneous smiling. Maxillary lip-line heights during spontaneous smiling were significantly higher than during posed smiling. Compared to spontaneous smiling, tooth display in the (pre)molar area during posed smiling decreased by up to 30%, along with a significant reduction of smile width. During posed smiling, also mandibular lip-line heights changed and the teeth were more covered by the lower lip than during spontaneous smiling. Reduced lip-line heights, tooth display, and smile width on a posed smiling record can have implications for the diagnostics of lip-line height, smile arc, buccal corridors, and plane of occlusion. Spontaneous smiling records next to posed smiling records are therefore recommended for diagnostic purposes. Because of the dynamic nature of spontaneous smiling, it is proposed to switch to dynamic video recording of the smile.

  18. Cold acclimation induces distinctive changes in the chromatin state and transcript levels of COR genes in Cannabis sativa varieties with contrasting cold acclimation capacities.

    Science.gov (United States)

    Mayer, Boris F; Ali-Benali, Mohamed Ali; Demone, Jordan; Bertrand, Annick; Charron, Jean-Benoit

    2015-11-01

    Little is known about the capacity of Cannabis sativa to cold-acclimate and develop freezing tolerance. This study investigates the cold acclimation (CA) capacity of nine C. sativa varieties and the underlying genetic and epigenetic responses. The varieties were divided into three groups based on their contrasting CA capacities by comparing the survival of non-acclimated and cold-acclimated plants in whole-plant freeze tests. In response to the CA treatment, all varieties accumulated soluble sugars but only the varieties with superior capacity for CA could maintain higher levels throughout the treatment. In addition, the varieties that acclimated most efficiently accumulated higher transcript levels of cold-regulated (COR) genes and genes involved in de novo DNA methylation while displaying locus- and variety-specific changes in the levels of H3K9ac, H3K27me3 and methylcytosine (MeC) during CA. Furthermore, these hardy C. sativa varieties displayed significant increases in MeC levels at COR gene loci when deacclimated, suggesting a role for locus-specific DNA methylation in deacclimation. This study uncovers the molecular mechanisms underlying CA in C. sativa and reveals higher levels of complexity regarding how genetic, epigenetic and environmental factors intertwine. © 2014 Scandinavian Plant Physiology Society.

  19. Brief history of electronic stereoscopic displays

    Science.gov (United States)

    Lipton, Lenny

    2012-02-01

    A brief history of recent developments in electronic stereoscopic displays is given concentrating on products that have succeeded in the market place and hence have had a significant influence on future implementations. The concentration is on plano-stereoscopic (two-view) technology because it is now the dominant display modality in the marketplace. Stereoscopic displays were created for the motion picture industry a century ago, and this technology influenced the development of products for science and industry, which in turn influenced product development for entertainment.

  20. Higher level WZW sectors from free fermions

    International Nuclear Information System (INIS)

    Boeckenhauer, J.

    1996-02-01

    We introduce a gauge group of internal symmetries of an ambient algebra as a new tool for investigating the superselection structure of WZW theories and the representation theory of the corresponding affine Lie algebras. The relevant ambient algebra arises from the description of these conformal field theories in terms of free fermions. As an illustration we analyze in detail the so(N) WZW theories at level two. In this case there is actually a homorphism from the representation ring of the gauge group to the WZW fusion ring, even though the level-two observable algebra is smaller than the gauge invariant subalgebra of the field algebra. (orig.)

  1. Advanced and tendencies in the development of display technologies

    Science.gov (United States)

    Kompanets, I. N.

    2006-06-01

    Advances and key display applications are discussed. Computer, compact mobile, TV and collective large screen displays are mentioned. Flat panel displays step on CRT devices to leave them behind in 2007. Materials, active matricies and applications of bright radiative field emission and organic LED displays are developing successively and pressing other technologies to be used in photo-cameras, cellular phones, auto-cars and avionics. Progress in flexible screens can substantially extend the display design and application soon. 3D display systems are under intensive development, and laser is an important unit in some vaiants of holographic and volumetric 3D displays. Value forecast of different display markets is presented.

  2. Color Analysis in Air Traffic Control Displays, Part II. Auxiliary Displays

    National Research Council Canada - National Science Library

    Xing, Jing

    2007-01-01

    ...), Traffic Management Advisor (TMA), and Integrated Terminal Weather System (ITWS). For each display, we documented the background and default colors, color-coding, color usage, associated purposes of color use, and color complexity...

  3. Predictors of Placement in Lower Level versus Higher Level High School Mathematics

    Science.gov (United States)

    Archbald, Doug; Farley-Ripple, Elizabeth N.

    2012-01-01

    Educators and researchers have long been interested in determinants of access to honors level and college prep courses in high school. Factors influencing access to upper level mathematics courses are particularly important because of the hierarchical and sequential nature of this subject and because students who finish high school with only lower…

  4. Visual Merchandising through Display: Advertising Services Occupations.

    Science.gov (United States)

    Maurer, Nelson S.

    The increasing use of displays by businessmen is creating a demand for display workers. This demand may be met by preparing high school students to enter the field of display. Additional workers might be recruited by offering adult training programs for individuals working within the stores. For this purpose a curriculum guide has been developed…

  5. 14 CFR 125.7 - Display of certificate.

    Science.gov (United States)

    2010-01-01

    ... OR MORE; AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT General § 125.7 Display of certificate. (a) The certificate holder must display a true copy of the certificate in each of its aircraft. (b... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Display of certificate. 125.7 Section 125.7...

  6. Evaluation of environmental education at higher secondary level in the model schools of Islamabad

    International Nuclear Information System (INIS)

    Tahir, F.; Ahmad, U.

    2000-01-01

    Environmental education (EE) has emerged as a new dimension in the dimensional sphere. It is a process aimed at the developing world's population, which should be well aware and concerned about the total environment and its associated problems and which should have knowledge, attitudes, skills, motivation and commitment to work, individually and collectively, towards the solution of current problems and the prevention of new ones. Evaluation is a process that provides feedback for the improvement of any project. The present study has been designed to investigate the current performance of EE at higher secondary level. Data were collected from Biology teachers and F. Sc. students of Islamabad Model Colleges, through separate questionnaires. The information collected from teachers was regarding their qualifications and involvement, institutional provisions and their opinion about EE. Students were evaluated on the basis of EE. The results showed that Biology is the only subject that contains a considerable content of EE at higher secondary level. In these institutions, although there is no deficiency of competent teaching staff, A/V aids and other physical facilities , the teacher's involvement and utility of teaching aids is not up to the mark, Book/magazines relevant to EE are not available in most of the institutions. Although students have enough knowledge and awareness about environmental issues, there is a need to produce appropriate skills and attitudes for making them 'environment-friendly'. (author)

  7. A higher level language data acquisition system (III) - the user data acquisition program

    International Nuclear Information System (INIS)

    Finn, J.M.; Gulbranson, R.L.; Huang, T.L.

    1983-01-01

    The nuclear physics group at the University of Illinois has implemented a data acquisition system using modified versions of the Concurrent Pascal and Sequential Pascal languages. The user, a physicist, develops a data acquisition ''operating system'', written in these higher level languages, which is tailored to the planned experiment. The user must include only those system functions which are essential to the task, thus improving efficiency. The user program is constructed from simple modules, mainly consisting of Concurrent Pascal PROCESSes, MONITORs, and CLASSes together with appropriate data type definitions. Entire programs can be put together using ''cut and paste'' techniques. Planned enhancements include the automating of this process. Systems written for the Perkin-Elmer 3220 using this approach can easily exceed 2 kHz data rates for event by event handling; 20 kHz data rates have been achieved by the addition of buffers in the interrupt handling software. These rates have been achieved without the use of special-purpose hardware such as micro-programmed branch drivers. With the addition of such devices even higher data rates should be possible

  8. [Peptide phage display in biotechnology and biomedicine].

    Science.gov (United States)

    Kuzmicheva, G A; Belyavskaya, V A

    2016-07-01

    To date peptide phage display is one of the most common combinatorial methods used for identifying specific peptide ligands. Phage display peptide libraries containing billions different clones successfully used for selection of ligands with high affinity and selectivity toward wide range of targets including individual proteins, bacteria, viruses, spores, different kind of cancer cells and variety of nonorganic targets (metals, alloys, semiconductors etc.) Success of using filamentous phage in phage display technologies relays on the robustness of phage particles and a possibility to genetically modify its DNA to construct new phage variants with novel properties. In this review we are discussing characteristics of the most known non-commercial peptide phage display libraries of different formats (landscape libraries in particular) and their successful applications in several fields of biotechnology and biomedicine: discovery of peptides with diagnostic values against different pathogens, discovery and using of peptides recognizing cancer cells, trends in using of phage display technologies in human interactome studies, application of phage display technologies in construction of novel nano materials.

  9. PathMAPA: a tool for displaying gene expression and performing statistical tests on metabolic pathways at multiple levels for Arabidopsis

    Directory of Open Access Journals (Sweden)

    Ma Ligeng

    2003-11-01

    Full Text Available Abstract Background To date, many genomic and pathway-related tools and databases have been developed to analyze microarray data. In published web-based applications to date, however, complex pathways have been displayed with static image files that may not be up-to-date or are time-consuming to rebuild. In addition, gene expression analyses focus on individual probes and genes with little or no consideration of pathways. These approaches reveal little information about pathways that are key to a full understanding of the building blocks of biological systems. Therefore, there is a need to provide useful tools that can generate pathways without manually building images and allow gene expression data to be integrated and analyzed at pathway levels for such experimental organisms as Arabidopsis. Results We have developed PathMAPA, a web-based application written in Java that can be easily accessed over the Internet. An Oracle database is used to store, query, and manipulate the large amounts of data that are involved. PathMAPA allows its users to (i upload and populate microarray data into a database; (ii integrate gene expression with enzymes of the pathways; (iii generate pathway diagrams without building image files manually; (iv visualize gene expressions for each pathway at enzyme, locus, and probe levels; and (v perform statistical tests at pathway, enzyme and gene levels. PathMAPA can be used to examine Arabidopsis thaliana gene expression patterns associated with metabolic pathways. Conclusion PathMAPA provides two unique features for the gene expression analysis of Arabidopsis thaliana: (i automatic generation of pathways associated with gene expression and (ii statistical tests at pathway level. The first feature allows for the periodical updating of genomic data for pathways, while the second feature can provide insight into how treatments affect relevant pathways for the selected experiment(s.

  10. Reactions of Air Transport Flight Crews to Displays of Weather During Simulated Flight

    Science.gov (United States)

    Bliss, James P.; Fallon, Corey; Bustamante, Ernesto; Bailey, William R., III; Anderson, Brittany

    2005-01-01

    . Measures of flight crew reactions included performance-based measures such as deviation decision accuracy, and judgment-based measures such as perceived decision confidence, workload, situation awareness, and display trust. Results demonstrated that pilots adopted a conservative reaction strategy, often choosing to deviate from weather rather than ride through it. When onboard and NEXRAD displays did not agree, flight crews reacted in a complex manner, trusting the onboard system more but using the NEXRAD system to augment their situation awareness. Distance to weather reduced situation awareness and heightened workload levels. Overall, flight crews tended to adopt a participative leadership style marked by open communication. These results suggest that future weather displays should exploit the existing benefits of NEXRAD presentation for situation awareness while retaining the display structure and logic inherent in the onboard system.

  11. Viewpoint adaptive display of HDR images

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Mantel, Claire

    2017-01-01

    In this paper viewpoint adaptive display of HDR images incorporating the effects of ambient light is presented and evaluated. LED backlight displays may render HDR images, but while at a global scale a high dynamic range may be achieved, locally the contrast is limited by the leakage of light...... through the LC elements of the display. To render high quality images, the display with backlight dimming can compute the values of the LED backlight and LC elements based on the input image, information about the viewpoint of the observer(s) and information of the ambient light. The goal is to achieve...... the best perceptual reproduction of the specified target image derived from the HDR input image in the specific viewing situation including multiple viewers, possibly having different preferences. An optimization based approach is presented. Some tests with reproduced images are also evaluated subjectively...

  12. Development and validation of a measure of display rule knowledge: the display rule assessment inventory.

    Science.gov (United States)

    Matsumoto, David; Yoo, Seung Hee; Hirayama, Satoko; Petrova, Galina

    2005-03-01

    As one component of emotion regulation, display rules, which reflect the regulation of expressive behavior, have been the topic of many studies. Despite their theoretical and empirical importance, however, to date there is no measure of display rules that assesses a full range of behavioral responses that are theoretically possible when emotion is elicited. This article reports the development of a new measure of display rules that surveys 5 expressive modes: expression, deamplification, amplification, qualification, and masking. Two studies provide evidence for its internal and temporal reliability and for its content, convergent, discriminant, external, and concurrent predictive validity. Additionally, Study 1, involving American, Russian, and Japanese participants, demonstrated predictable cultural differences on each of the expressive modes. Copyright 2005 APA, all rights reserved.

  13. Display analysis with the optimal control model of the human operator. [pilot-vehicle display interface and information processing

    Science.gov (United States)

    Baron, S.; Levison, W. H.

    1977-01-01

    Application of the optimal control model of the human operator to problems in display analysis is discussed. Those aspects of the model pertaining to the operator-display interface and to operator information processing are reviewed and discussed. The techniques are then applied to the analysis of advanced display/control systems for a Terminal Configured Vehicle. Model results are compared with those obtained in a large, fixed-base simulation.

  14. Instrument-mounted displays for reducing cognitive load during surgical navigation.

    Science.gov (United States)

    Herrlich, Marc; Tavakol, Parnian; Black, David; Wenig, Dirk; Rieder, Christian; Malaka, Rainer; Kikinis, Ron

    2017-09-01

    Surgical navigation systems rely on a monitor placed in the operating room to relay information. Optimal monitor placement can be challenging in crowded rooms, and it is often not possible to place the monitor directly beside the situs. The operator must split attention between the navigation system and the situs. We present an approach for needle-based interventions to provide navigational feedback directly on the instrument and close to the situs by mounting a small display onto the needle. By mounting a small and lightweight smartwatch display directly onto the instrument, we are able to provide navigational guidance close to the situs and directly in the operator's field of view, thereby reducing the need to switch the focus of view between the situs and the navigation system. We devise a specific variant of the established crosshair metaphor suitable for the very limited screen space. We conduct an empirical user study comparing our approach to using a monitor and a combination of both. Results from the empirical user study show significant benefits for cognitive load, user preference, and general usability for the instrument-mounted display, while achieving the same level of performance in terms of time and accuracy compared to using a monitor. We successfully demonstrate the feasibility of our approach and potential benefits. With ongoing technological advancements, instrument-mounted displays might complement standard monitor setups for surgical navigation in order to lower cognitive demands and for improved usability of such systems.

  15. Mind the Gap: An Initial Analysis of the Transition of a Second Level Curriculum Reform to Higher Education

    Science.gov (United States)

    Prendergast, Mark; Faulkner, Fiona; Breen, Cormac; Carr, Michael

    2017-01-01

    This article details an initial analysis of the transition of a second level curriculum reform to higher education in Ireland. The reform entitled 'Project Maths' involved changes to what second level students learn in mathematics, how they learn it, and how they are assessed. Changes were rolled out nationally on a phased basis in September 2010.…

  16. Hierarchy of higher-level physical functions: a longitudinal investigation on a nationally representative population of community-dwelling middle-aged and elderly persons.

    Science.gov (United States)

    Yeh, Chih-Jung; Wang, Ching-Yi; Tang, Pei-Fang; Lee, Meng-Chih; Lin, Hui-Sheng; Chen, Hui-Ya

    2012-01-01

    Understanding the hierarchy of higher-level physical functions to infer disability level (mild, moderate or severe) is essential for the precise targeting of preventive interventions and has been examined previously in a cross-sectional study. Based on longitudinal data, this study evaluated the hierarchy of higher-level physical functions. Data from a cohort of 2729 community-dwelling persons aged over 50 with no initial disability were drawn from the "Survey of Health and Living Status of the Elderly in Taiwan" from 1996 through 2007. The three-level hierarchy of eight chosen activities was examined by the median ages to disability onset with survival analyses and by Cox regressions, which examined the effects of sex and age on the development of this hierarchy. The progression of incident disability was as follows: mild level-running, carrying weight, and squatting; moderate level-climbing stairs, walking, and standing; and severe level-grasping and raising arms up. Women and older persons were at greater risk of developing more severe levels of disability. Another Cox regression with one index activity from each hierarchical level revealed similar results. The three-level hierarchy of higher-level physical functions has been validated longitudinally, suggesting rich research and clinical implications.

  17. Students' Commitment, Engagement and Locus of Control as Predictor of Academic Achievement at Higher Education Level

    Science.gov (United States)

    Sarwar, Muhammad; Ashrafi, Ghulam Muhammad

    2014-01-01

    The purpose of this study was to analyze Students' Commitment, Engagement and Locus of Control as predictors of Academic Achievement at Higher Education Level. We used analytical model and conclusive research approach to conduct study and survey method for data collection. We selected 369 students using multistage sampling technique from three…

  18. Higher levels of albuminuria within the normal range predict incident hypertension.

    Science.gov (United States)

    Forman, John P; Fisher, Naomi D L; Schopick, Emily L; Curhan, Gary C

    2008-10-01

    Higher levels of albumin excretion within the normal range are associated with cardiovascular disease in high-risk individuals. Whether incremental increases in urinary albumin excretion, even within the normal range, are associated with the development of hypertension in low-risk individuals is unknown. This study included 1065 postmenopausal women from the first Nurses' Health Study and 1114 premenopausal women from the second Nurses' Health Study who had an albumin/creatinine ratio who did not have diabetes or hypertension. Among the older women, 271 incident cases of hypertension occurred during 4 yr of follow-up, and among the younger women, 296 incident cases of hypertension occurred during 8 yr of follow-up. Cox proportional hazards regression was used to examine prospectively the association between the albumin/creatinine ratio and incident hypertension after adjustment for age, body mass index, estimated GFR, baseline BP, physical activity, smoking, and family history of hypertension. Participants who had an albumin/creatinine ratio in the highest quartile (4.34 to 24.17 mg/g for older women and 3.68 to 23.84 mg/g for younger women) were more likely to develop hypertension than those who had an albumin/creatinine ratio in the lowest quartile (hazard ratio 1.76 [95% confidence interval 1.21 to 2.56] and hazard ratio 1.35 [95% confidence interval 0.97 to 1.91] for older and younger women, respectively). Higher albumin/creatinine ratios, even within the normal range, are independently associated with increased risk for development of hypertension among women without diabetes. The definition of normal albumin excretion should be reevaluated.

  19. Developing an integrated digitizing and display surface

    Science.gov (United States)

    Hipple, James D.; Wedding, Daniel K.; Wedding, Donald K., Sr.

    1995-04-01

    The development of an integrated digitizing and display surface, which utilizes touch entry and flat panel display (FPD) technology, is a significant hardware advance in the field of geographic information systems (GIS). Inherent qualities of the FPD, notably the ac gas plasma display, makes such a marriage inevitable. Large diagonal sizes, high resolution color, screen flatness, and monitor thickness are desirable features of an integrated digitizing and display surface. Recently, the GIS literature has addressed a need for such an innovation. The development of graphics displays based on sophisticated technologies include `photorealistic' (or high definition) imaging at resolutions of 2048 X 2048 or greater, palates of 16.7 million colors, formats greater than 30 inches diagonal, and integrated touch entry. In this paper, there is an evaluation of FPDs and data input technologies in the development of such a product.

  20. Baculovirus virions displaying Plasmodium berghei circumsporozoite protein protect mice against malaria sporozoite infection

    International Nuclear Information System (INIS)

    Yoshida, Shigeto; Kondoh, Daisuke; Arai, Eriko; Matsuoka, Hiroyuki; Seki, Chisato; Tanaka, Takao; Okada, Masaji; Ishii, Akira

    2003-01-01

    The display of foreign proteins on the surface of baculovirus virions has provided a tool for the analysis of protein-protein interactions and for cell-specific targeting in gene transfer applications. To evaluate the baculovirus display system as a vaccine vehicle, we have generated a recombinant baculovirus (AcNPV-CSPsurf) that displays rodent malaria Plasmodium berghei circumsporozoite protein (PbCSP) on the virion surface as a fusion protein with the major baculovirus envelope glycoprotein gp64. The PbCSP-gp64 fusion protein was incorporated and oligomerized on the virion surface and led to a 12-fold increase in the binding activity of AcNPV-CSPsurf virions to HepG2 cells. Immunization with adjuvant-free AcNPV-CSPsurf virions induced high levels of antibodies and gamma interferon-secreting cells against PbCSP and protected 60% of mice against sporozoite challenge. These data demonstrate that AcNPV-CSPsurf displays sporozoite-like PbCSP on the virion surface and possesses dual potentials as a malaria vaccine candidate and a liver-directed gene delivery vehicle

  1. Helmet-mounted display requirements: just another head-up display (HUD) or a different animal altogether?

    Science.gov (United States)

    Newman, Richard L.; Haworth, Loran A.

    1994-06-01

    The helmet-mounted display (HMD) presents flight, navigation, and weapon information in the pilot's line of sight. The HMD was developed to allow the pilot to retain aircraft and weapon information while looking off boresight. The present study reviewed the state-of-the-art in HMDs and identified a number of issues applying to HMDs. Several are identical to head-up display (HUD) issues: symbol standardization, excessive clutter, and the need for integration with other cockpit displays and controls. Other issues are unique to the head-mounted display: symbol stabilization, inadequate definitions, undefined symbol drive laws, helmet considerations, and field-of-view (FOV) vs. resolution tradeoff requirements. Symbol stabilization is critical. In the Apache helicopter, the lack of compensation for pilot head motion creates excessive workload during hovering and nap-of-the-earth (NOE) flight. This high workload translates into excessive training requirements. At the same time, misleading symbology makes interpretation of the height of obstructions impossible. The underlying cause is the absence of design criteria for HMDs. The existing military standard does not reflect the current state of technology. In addition, there are inadequate test and evaluation guidelines. The situation parallels the situation for HUDs several years ago.

  2. Use resources of human exometabolites of different oxidation levels for higher plants cultivation on the soil-like substrate as applied to closed ecosystems

    Science.gov (United States)

    Tikhomirov, Alexander A.; Kudenko, Yurii; Ushakova, Sofya; Tirranen, Lyalya; Gribovskaya, Illiada; Gros, Jean-Bernard; Lasseur, Christophe

    The technology of ‘wet incineration' of human exometabolites and inedible plants biomass by means of H2 O2 in alternating electromagnetic field to increase a closure of mass exchange processes in bioregenerative life support systems (BLSS) was developed at the Institute of Biophysics of the Siberian Branch of Russian Academy of Sciences (Krasnoyarsk, Russia). Human exometabolites mineralized can be used in a nutrient solution for plants cultivation in the BLSS phototrophic link. The objective of the given work appears to be the study of use resources of human exometabolites of different oxidation levels processed by the abovementioned method for higher plants cultivation on the soil-like substrate (SLS). The mineralized human wastes were tested for the purpose of their sterility. Then the effect of human exometabolites of different oxidation levels both on wheat productivity and on the SLS microflora composition was examined. The SLS extract with a definite amount of human mineralized wastes was used as an irrigation solution. The conducted experiments demonstrated that the H2 O2 decreasing to 1 ml on 1 g of feces and to 0.25 ml on 1 ml of urine had not affected the sterility of mineralized human wastes. Wheat cultivation on the SLS with the addition in an irrigation solution of mineralized human wastes in the amount simulating 1/6 of a daily human diet showed the absence of basic dependence of plants productivity on oxidation level of human exometabolites. Yet the analysis of the microflora composition of the irrigation solutions demonstrated its dependence on the oxidation level of the exometabolites introduced. The amount of yeast-like fungi increased in 20 times in the solutions containing less oxidized exometabolites in comparison with the variant in which the human wastes were subjected to a full-scale oxidation. Besides, the solutions with less oxidized exometabolites displayed a bigger content of plant pathogenic bacteria and denitrifies. Consequently the

  3. Autostereoscopic display technology for mobile 3DTV applications

    Science.gov (United States)

    Harrold, Jonathan; Woodgate, Graham J.

    2007-02-01

    Mobile TV is now a commercial reality, and an opportunity exists for the first mass market 3DTV products based on cell phone platforms with switchable 2D/3D autostereoscopic displays. Compared to conventional cell phones, TV phones need to operate for extended periods of time with the display running at full brightness, so the efficiency of the 3D optical system is key. The desire for increased viewing freedom to provide greater viewing comfort can be met by increasing the number of views presented. A four view lenticular display will have a brightness five times greater than the equivalent parallax barrier display. Therefore, lenticular displays are very strong candidates for cell phone 3DTV. Selection of Polarisation Activated Microlens TM architectures for LCD, OLED and reflective display applications is described. The technology delivers significant advantages especially for high pixel density panels and optimises device ruggedness while maintaining display brightness. A significant manufacturing breakthrough is described, enabling switchable microlenses to be fabricated using a simple coating process, which is also readily scalable to large TV panels. The 3D image performance of candidate 3DTV panels will also be compared using autostereoscopic display optical output simulations.

  4. Service Level Status

    CERN Multimedia

    Lopienski, S

    2007-01-01

    Nowadays, IT departments provide, and people use, computing services of an increasingly heterogeneous nature. There is thus a growing need for a status display that groups these different services and reports status and availability in a uniform way. The Service Level Status (SLS) system addresses these needs by providing a web-based display that dynamically shows availability, basic information and statistics about various IT services, as well as the dependencies between them.

  5. Flow cytometric measurement of DNA level and steroid hormone receptor assay in breast cancer

    International Nuclear Information System (INIS)

    Zubrikhina, G.N.; Kuz'mina, Eh.V.; Bassalyk, L.S.; Murav'eva, N.I.

    1989-01-01

    DNA level measured by flow cytometry and estrogen and progesteron receptors assayed in tissue samples obtained from 85 malignant and 16 benign lesions of the breast. All the benign tumors revealed 2c DNA content and most of them were receptor-negative, while 74.1% of breast carcinomas displayed aneuploidy. Three patients (3.5%) had two lines of aneuploid cells. Many aneuploid tumors were receptor-negative. Preoperative radiation treatmet (14-20 Gy) did not significantly influence the level of steroid hormone receptors in tumors. Estrogen receptor level was higher in menopausal patients than in premenopausal ones

  6. Advanced image display systems in radiology

    International Nuclear Information System (INIS)

    Wendler, T.

    1987-01-01

    Advanced image display systems for the fully digital diagnostic imaging departments of the future will be far more than simple replacements of the traditional film-viewing equipment. The new capabilities of very high resolution and highly dynamic displays offer a userfriendly and problem-oriented way of image interpretation. Advanced harware-, software- and human-machine interaction-concepts have been outlined. A scenario for a future way of handling and displaying images, reflecting a new image viewing paradigm in radiology is sketched which has been realized in an experimental image workstation model in the laboratory which, despite its technical complexity, offers a consistent strategy for fast and convenient interaction with image objects. The perspective of knowledge based techniques for workstation control software with object-oriented programming environments and user- and task-adaptive behavior leads to more advanced display properties and a new quality of userfriendliness. 2 refs.; 5 figs

  7. Critical Sociological Thinking and Higher-Level Thinking: A Study of Sociologists' Teaching Goals and Assignments

    Science.gov (United States)

    Kane, Danielle; Otto, Kristin

    2018-01-01

    We argue that the literature on critical thinking in sociology has conflated two different skill sets: critical sociological thinking and higher-level thinking. To begin to examine how sociologists weigh and cultivate these skill sets, we interviewed 20 sociology instructors and conducted a content analysis of 26 assignments. We found that while…

  8. Three-dimensional display improves observer speed and accuracy

    International Nuclear Information System (INIS)

    Nelson, J.A.; Rowberg, A.H.; Kuyper, S.; Choi, H.S.

    1989-01-01

    In an effort to evaluate the potential cost-effectiveness of three-dimensional (3D) display equipment, we compared the speed and accuracy of experienced radiologists identifying in sliced uppercase letters from CT scans with 2D and pseudo-3D display. CT scans of six capital letters were obtained and printed as a 2D display or as a synthesized pseudo-3D display (Pixar). Six observes performed a timed identification task. Radiologists read the 3D display an average of 16 times faster than the 2D, and the average error rate of 2/6 (± 0.6/6) for 2D interpretations was totally eliminated. This degree of improvement in speed and accuracy suggests that the expense of 3D display may be cost-effective in a defined clinical setting

  9. Demonstration of Vibrational Braille Code Display Using Large Displacement Micro-Electro-Mechanical Systems Actuators

    Science.gov (United States)

    Watanabe, Junpei; Ishikawa, Hiroaki; Arouette, Xavier; Matsumoto, Yasuaki; Miki, Norihisa

    2012-06-01

    In this paper, we present a vibrational Braille code display with large-displacement micro-electro-mechanical systems (MEMS) actuator arrays. Tactile receptors are more sensitive to vibrational stimuli than to static ones. Therefore, when each cell of the Braille code vibrates at optimal frequencies, subjects can recognize the codes more efficiently. We fabricated a vibrational Braille code display that used actuators consisting of piezoelectric actuators and a hydraulic displacement amplification mechanism (HDAM) as cells. The HDAM that encapsulated incompressible liquids in microchambers with two flexible polymer membranes could amplify the displacement of the MEMS actuator. We investigated the voltage required for subjects to recognize Braille codes when each cell, i.e., the large-displacement MEMS actuator, vibrated at various frequencies. Lower voltages were required at vibration frequencies higher than 50 Hz than at vibration frequencies lower than 50 Hz, which verified that the proposed vibrational Braille code display is efficient by successfully exploiting the characteristics of human tactile receptors.

  10. To 'display' or not to 'display'- that is the peptide

    CSIR Research Space (South Africa)

    Crampton, Michael C

    2008-11-01

    Full Text Available eukaryotic and prokaryotic systems but has mainly focused around phages (Etz et al, 2001), yeast (Kondo and Ueda, 2004) and bacteria (Lee et al 2003). The central variable domain of the FliC protein is dispensable and can be used for the insertion and display...

  11. A study of quantitative scale display of the organ uptake with gamma-camera

    Energy Technology Data Exchange (ETDEWEB)

    Ishigami, K; Matsumoto, M [Kumamoto Univ. (Japan) School of Medicine

    1975-05-01

    The fundamental study of quantitative scale display of the organ uptake with ..gamma..-camera was performed in special respect of the thyroid gland and the pancreas. As one of the measurements on certain dimension of the organ, an optical progression outside the digital image was expressed, and was subjected to the quantitative scale with the use of the threshold level. And a rather satisfactory correlation was clinically obtained between the scale display and the thyroidal /sup 131/I uptake. For the purpose of revising the above scale display, the organ depth was measured with RI by the aid of the phantom. Then the pancreas depth determined by the count rate ratio curve of 140 and 270 keV peak of /sup 75/Se energies. However, the body background and the radioactive rays from the neighboring organs interfered with this curve.

  12. A higher level of education amplifies the inverse association between income and disability in the Spanish elderly.

    Science.gov (United States)

    Abellán, Antonio; Rodríguez-Laso, Ángel; Pujol, Rogelio; Barrios, Laura

    2015-12-01

    This paper aims to estimate if the education level modifies the association of income with disability prevalence in the elderly. Education can have a confounding effect on income or interact with it as a health determinant. It is important to analyze the relationship between socio-economic status and disability in older people, because it helps to better understand health inequalities and organize appropriate social policies. The study is based on the Survey on Disability, Personal Autonomy and Dependency Situations (Spanish National Statistics Institute). Binary logistic regression models are adjusted (bivariate, adjusted for gender and age, with all variables and with the interaction between income and education levels). A bad adjustment of the model is detected and a scobit link is added, which helps to differentiate disabled and non-disabled individuals better. People with difficulty in carrying out activities of daily living are much older, frequently women and with low education and income levels. The significant interaction between education level and income means that the odds of being disabled is 43% less in people of high income compared with people of low income if they are well educated, while it is only 21%, among those with low education. A higher education level amplifies significantly the inverse association between income and disability in the Spanish elderly, what suggests that those with higher education will profit more than those with lower education from universal economic benefits policies aimed at the disabled, increasing health inequalities between groups.

  13. Functional displays

    International Nuclear Information System (INIS)

    Angelis De, F.; Haentjens, J.

    1995-01-01

    The Functional Displays are directly derived from the Man-Machine Design key document: Function-Based Task Analysis. The presentation defines and describes the goals-means structure of the plant function along with applicable control volumes and parameters of interest. The purpose of the subject is to show, through an example of a preliminary design, what the main parts of a function are. (3 figs.)

  14. Display hardware

    International Nuclear Information System (INIS)

    Myers, D.R.

    1983-01-01

    To appreciate the limitations and possibilities of computer graphics it is necessary to have some acquaintance with the available technology. The aim of this chapter is to mention briefly the different display types and their 'ball-park' price ranges. It must be stressed that prices change rapidly, and so those quoted here are only intended to give an idea of the cost at the time of writing.

  15. A visual-display and storage device

    Science.gov (United States)

    Bosomworth, D. R.; Moles, W. H.

    1972-01-01

    Memory and display device uses cathodochromic material to store visual information and fast phosphor to recall information for display and electronic processing. Cathodochromic material changes color when bombarded with electrons, and is restored to its original color when exposed to light of appropiate wavelength.

  16. NCAP projection displays: key issues for commercialization

    Science.gov (United States)

    Tomita, Akira; Jones, Philip J.

    1992-06-01

    Recently there has been much interest in a new polymer nematic dispersion technology, often called as NCAP, PDLC, PNLC, LCPC, etc., since projection displays using this technology have been shown to produce much brighter display images than projectors using conventional twisted nematic (TN) lightvalves. For commercializing projection displays based on this polymer nematic dispersion technology, the new materials must not only meet various electro- optic requirements, e.g., operational voltage, `off-state'' scattering angle, voltage holding ratio and hysteresis, but must also be stable over the lifetime of the product. This paper reports recent progress in the development of NCAP based projection displays and discusses some of the key commercialization issues.

  17. Polyvalent Display of Biomolecules on Live Cells.

    Science.gov (United States)

    Shi, Peng; Zhao, Nan; Lai, Jinping; Coyne, James; Gaddes, Erin R; Wang, Yong

    2018-06-04

    Surface display of biomolecules on live cells offers new opportunities to treat human diseases and perform basic studies. Existing methods are primarily focused on monovalent functionalization, that is, the display of single biomolecules across the cell surface. Here we show that the surface of live cells can be functionalized to display polyvalent biomolecular structures through two-step reactions under physiological conditions. This polyvalent functionalization enables the cell surface to recognize the microenvironment one order of magnitude more effectively than with monovalent functionalization. Thus, polyvalent display of biomolecules on live cells holds great potential for various biological and biomedical applications. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. PENGARUH DISPLAY PRODUK PADA KEPUTUSAN PEMBELIAN KONSUMEN

    Directory of Open Access Journals (Sweden)

    Ina Melati

    2012-11-01

    Full Text Available Most of ritel outlet recently using product display as a one of their best marketing strategy, the reason is quiet easy to be understood, since consumers are too easy to be teased by those kind of beautiful product display that is being displayed by the retail outlet. The good retail outlets are trying their best to design and make the very good product display, so they can attract more consumers and make them not thinking twice to visit their store and purchase lots of thing. Clearly seeing that an attractive product design is able to influence a consumer to make a buying decision. 

  19. Pilot stereotypes for navigation symbols on electronic displays

    Science.gov (United States)

    2006-09-20

    There is currently no common symbology standard for the : electronic display of navigation information. The wide : range of display technologies and the different functions : these displays support make it difficult to design symbols : that are easil...

  20. Biomechanics of the Peacock’s Display: How Feather Structure and Resonance Influence Multimodal Signaling

    Science.gov (United States)

    Dakin, Roslyn; McCrossan, Owen; Hare, James F.; Montgomerie, Robert; Amador Kane, Suzanne

    2016-01-01

    Courtship displays may serve as signals of the quality of motor performance, but little is known about the underlying biomechanics that determines both their signal content and costs. Peacocks (Pavo cristatus) perform a complex, multimodal “train-rattling” display in which they court females by vibrating the iridescent feathers in their elaborate train ornament. Here we study how feather biomechanics influences the performance of this display using a combination of field recordings and laboratory experiments. Using high-speed video, we find that train-rattling peacocks stridulate their tail feathers against the train at 25.6 Hz, on average, generating a broadband, pulsating mechanical sound at that frequency. Laboratory measurements demonstrate that arrays of peacock tail and train feathers have a broad resonant peak in their vibrational spectra at the range of frequencies used for train-rattling during the display, and the motion of feathers is just as expected for feathers shaking near resonance. This indicates that peacocks are able to drive feather vibrations energetically efficiently over a relatively broad range of frequencies, enabling them to modulate the feather vibration frequency of their displays. Using our field data, we show that peacocks with longer trains use slightly higher vibration frequencies on average, even though longer train feathers are heavier and have lower resonant frequencies. Based on these results, we propose hypotheses for future studies of the function and energetics of this display that ask why its dynamic elements might attract and maintain female attention. Finally, we demonstrate how the mechanical structure of the train feathers affects the peacock’s visual display by allowing the colorful iridescent eyespots–which strongly influence female mate choice–to remain nearly stationary against a dynamic iridescent background. PMID:27119380

  1. The influence of lip form on incisal display with lips in repose on the esthetic preferences of dentists and lay people.

    Science.gov (United States)

    Kim, Jee; Topolski, Richard; Dickinson, Douglas; Ramos, Van

    2017-09-01

    Information is lacking for viewer preferences for incisal display with lips in repose. The purpose of this online survey was to establish measurement parameters to classify and define a lip form and to evaluate the influence of lip form on dentists' and laypersons' preferences for the amount of incisal display with lips in repose. Computer-generated male and female models were created using 3 different lip forms each, straight, moderate, and high. Three images of these models (frontal full face, zoomed-in frontal around the mouth, and oblique zoomed-in image of the mouth) were arranged in an interactive survey that was disseminated on the Websites Facebook, Instagram, DentalTown and by word-of-mouth. Respondents manipulated the incisal display of all 3 images in unison, using a slide bar, and the resulting incisal display was measured in millimeters and served as the primary dependent measure. Survey demographic data were obtained from an online survey site. Data were assessed for skewness, kurtosis, and outliers and analyzed with 5-way ANOVA: 2 sex levels for model, 2 levels for sex of respondent, 3 levels for lip height, 3 levels for occupation, and 5 levels of ethnicity, with multiple comparisons corrected with Bonferroni adjustments and post hoc comparisons performed using the Scheffé test (α=.05 for all comparisons). A total of 1039 individuals consented to the study. A final sample size of 687 respondents was obtained after excluding 352 who failed to complete the survey. The results indicated that lip form affected the esthetic perception of incisal display significantly (P<.001), with a preference for a greater amount of incisal display corresponding with increasing lip forms. Sex of the model was also significant, with greater incisal display being preferred for female faces. A significant difference was found for respondents' ethnicity, with African Americans generally preferring smaller incisal displays than other ethnic groups. No other main effects

  2. Registration and display of brain SPECT and MRI using external markers

    International Nuclear Information System (INIS)

    Pohjonen, H.; Nikkinen, P.; Sipilae, O.; Launes, J.; Salli, E.; Salonen, O.; Karp, P.; Ylae-Jaeaeski, J.; Katila, T.; Liewendahl, K.

    1996-01-01

    Accurate anatomical localisation of abnormalities observed in brain perfusion single-photon emission computed tomography (SPECT) is difficult, but can be improved by correlating data from SPECT and other tomographic imaging modalities. For this purpose we have developed software to register, analyse and display 99m Tc-hexamethylpropyleneamine oxime SPECT and 1.0 T MRI of the brain. For registration of SPECT and MRI data external skin markers containing 99m Tc (220 kBq) in 50 μl of coconut butter were used. The software is coded in the C programming language, and the X Window system and the OSF/Motif standards are used for graphics and definition of the user interface. The registration algorithm follows a noniterative least-squares method using singular value decomposition of a 3 x 3 covariance matrix. After registration, the image slices of both data sets are shown at identical tomographic levels. The registration error in phantom studies was on average 4 mm. In the two-dimensional display mode the orthogonal cross-sections of the data sets are displayed side by side. In the three-dimensional mode MRI data are displayed as a surface-shaded 3 D reconstruction and SPECT data as cut planes. The usefulness of this method is demonstrated in patients with cerebral infarcts, brain tumour, herpes simplex encephalitis and epilepsy. (orig.). With 9 figs

  3. Raising an Antibody Specific to Breast Cancer Subpopulations Using Phage Display on Tissue Sections

    DEFF Research Database (Denmark)

    Larsen, Simon Asbjørn; Meldgaard, Theresa; Fridriksdottir, Agla Jael Rubner

    2016-01-01

    BACKGROUND/AIM: Primary tumors display a great level of intra-tumor heterogeneity in breast cancer. The current lack of prognostic and predictive biomarkers limits accurate stratification and the ability to predict response to therapy. The aim of the present study was to select recombinant antibody...... fragments specific against breast cancer subpopulations, aiding the discovery of novel biomarkers. MATERIALS AND METHODS: Recombinant antibody fragments were selected by phage display. A novel shadowstick technology enabled the direct selection using tissue sections of antibody fragments specific against...

  4. Evaluating Ambient Displays in the Wild

    DEFF Research Database (Denmark)

    Messeter, Jörn; Molenaar, Daryn

    A prominent issue for evaluating ambient displays has been the conflict between the relative intrusiveness of evaluation methods and the intention to keep the display at the periphery of the user’s attention. There is a general lack of research discussing the difficulties of evaluating ambient di...

  5. Panoramic, large-screen, 3-D flight display system design

    Science.gov (United States)

    Franklin, Henry; Larson, Brent; Johnson, Michael; Droessler, Justin; Reinhart, William F.

    1995-01-01

    The report documents and summarizes the results of the required evaluations specified in the SOW and the design specifications for the selected display system hardware. Also included are the proposed development plan and schedule as well as the estimated rough order of magnitude (ROM) cost to design, fabricate, and demonstrate a flyable prototype research flight display system. The thrust of the effort was development of a complete understanding of the user/system requirements for a panoramic, collimated, 3-D flyable avionic display system and the translation of the requirements into an acceptable system design for fabrication and demonstration of a prototype display in the early 1997 time frame. Eleven display system design concepts were presented to NASA LaRC during the program, one of which was down-selected to a preferred display system concept. A set of preliminary display requirements was formulated. The state of the art in image source technology, 3-D methods, collimation methods, and interaction methods for a panoramic, 3-D flight display system were reviewed in depth and evaluated. Display technology improvements and risk reductions associated with maturity of the technologies for the preferred display system design concept were identified.

  6. White constancy method for mobile displays

    Science.gov (United States)

    Yum, Ji Young; Park, Hyun Hee; Jang, Seul Ki; Lee, Jae Hyang; Kim, Jong Ho; Yi, Ji Young; Lee, Min Woo

    2014-03-01

    In these days, consumer's needs for image quality of mobile devices are increasing as smartphone is widely used. For example, colors may be perceived differently when displayed contents under different illuminants. Displayed white in incandescent lamp is perceived as bluish, while same content in LED light is perceived as yellowish. When changed in perceived white under illuminant environment, image quality would be degraded. Objective of the proposed white constancy method is restricted to maintain consistent output colors regardless of the illuminants utilized. Human visual experiments are performed to analyze viewers'perceptual constancy. Participants are asked to choose the displayed white in a variety of illuminants. Relationship between the illuminants and the selected colors with white are modeled by mapping function based on the results of human visual experiments. White constancy values for image control are determined on the predesigned functions. Experimental results indicate that propsed method yields better image quality by keeping the display white.

  7. Higher levels of masculine gender role stress in masculine than in feminine nations. A thirteen-nations study

    NARCIS (Netherlands)

    Arrindell, W.A.; van Well, S.; Kolk, A.M.; Barelds, D.P.H.; Oei, T.P.S.; Lau, P.Y.

    2013-01-01

    It was hypothesized that societies that put greater emphasis on men being rigidly committed to culturally accepted models of masculinity (nations with high Hofstede MASculinity scores) would report higher mean national levels of masculine gender role stress (MGRS) than societies that emphasize such

  8. Higher Levels of Masculine Gender Role Stress in Masculine than in Feminine Nations : A Thirteen-Nations Study

    NARCIS (Netherlands)

    Arrindell, W. A.; van Well, Sonja; Kolk, Annemarie M.; Barelds, Dick P. H.; Oei, Tian P. S.; Lau, Pui Yi

    It was hypothesized that societies that put greater emphasis on men being rigidly committed to culturally accepted models of masculinity (nations with high Hofstede MASculinity scores) would report higher mean national levels of masculine gender role stress (MGRS) than societies that emphasize such

  9. Investigating pointing tasks across angularly coupled display areas

    DEFF Research Database (Denmark)

    Hennecke, Fabian; De Luca, Alexander; Nguyen, Ngo Dieu Huong

    2013-01-01

    Pointing tasks are a crucial part of today’s graphical user interfaces. They are well understood for flat displays and most prominently are modeled through Fitts’ Law. For novel displays (e.g., curved displays with multi-purpose areas), however, it remains unclear whether such models for predicting...... that the target position affects overall pointing speed and offset in both conditions. However, we also found that Fitts’ Law can in fact still be used to predict performance as on flat displays. Our results help designers to optimize user interfaces on angularly coupled displays when pointing tasks are involved....... user performance still hold – in particular when pointing is performed across differently oriented areas. To answer this question, we conducted an experiment on an angularly coupled display – the Curve – with two input conditions: direct touch and indirect mouse pointer. Our findings show...

  10. Laser display system for multi-depth screen projection scenarios.

    Science.gov (United States)

    La Torre, J Pablo; Mayes, Nathan; Riza, Nabeel A

    2017-11-10

    Proposed is a laser projection display system that uses an electronically controlled variable focus lens (ECVFL) to achieve sharp and in-focus image projection over multi-distance three-dimensional (3D) conformal screens. The system also functions as an embedded distance sensor that enables 3D mapping of the multi-level screen platform before the desired laser scanned beam focused/defocused projected spot sizes are matched to the different localized screen distances on the 3D screen. Compared to conventional laser scanning and spatial light modulator (SLM) based projection systems, the proposed design offers in-focus non-distorted projection over a multi-distance screen zone with varying depths. An experimental projection system for a screen depth variation of 65 cm is demonstrated using a 633 nm laser beam, 3 KHz scan speed galvo-scanning mirrors, and a liquid-based ECVFL. As a basic demonstration, an in-house developed MATLAB based graphic user interface is deployed to work along with the laser projection display, enabling user inputs like text strings or predefined image projection. The user can specify projection screen distance, scanned laser linewidth, projected text font size, projected image dimensions, and laser scanning rate. Projected images are shown highlighting the 3D control capabilities of the display, including the production of a non-distorted image onto two-depths versus a distorted image via dominant prior-art projection methods.

  11. User interface design in safety parameter display systems

    International Nuclear Information System (INIS)

    Schultz, E.E. Jr.; Johnson, G.L.

    1988-01-01

    The extensive installation of computerized safety Parameter Display Systems (SPDSs) in nuclear power plants since the Three-Mile Island accident has enhanced plant safety. It has also raised new issues of how best to ensure an effective interface between human operators and the plant via computer systems. New developments in interface technologies since the current generation of SPDSs was installed can contribute to improving display interfaces. These technologies include new input devices, three-dimensional displays, delay indicators, and auditory displays. Examples of how they might be applied to improve current SPDSs are given. These examples illustrate how the new use interface technology could be applied to future nuclear plant displays

  12. Analyzing of the self reported ICT literacy level of Slovakian and Serbian Students in the higher education

    Directory of Open Access Journals (Sweden)

    Kiss Gabor

    2017-01-01

    Full Text Available The students generally use technology for communication in the European Union and outside of the Union. First of all we have to see in this research the ICT knowledge level of the students in the higher education to make decision about the application and retraining methods. It is important to know can we find any difference in ICT literacy between the Slovakian and the Serbian students to see how long is the way to finish the ICT revolution in these countries. On the other hand is it important to see which topic need more attention from the teachers in the high school to give a good knowledge for the student before they go in the higher education. We measured the ICT literacy level with a tool consisting of 15 items (Likert scaled. The data analysis was performed with SPSS software using descriptive statistics and Mann-Whitney test.

  13. Position display device

    International Nuclear Information System (INIS)

    Nishizawa, Yukio.

    1974-01-01

    Object: To provide a device capable of easily and quickly reading mutual mounting relations of control bodies such as control rods mounted on a nuclear reactor and positions to which the control bodies are driven. Structure: A scanning circuit is provided to scan positions of controllably mounted control bodies such as control rods. Values detected by scanning the positions are converted into character signals according to the values and converted into preranked color signals. The character signals and color signals are stored in a memory circuit by synchronous signals in synchronism with the scanning in the scanning circuit. Outputs of the memory circuit are displayed by a display unit such as a color Braun tube in accordance with the synchronous signals to provide color representations according to positions to which control bodies are driven in the same positional relation as the mounting of the control bodies. (Kamimura, M.)

  14. EFFECTS OF HIGHER LEVELS OF CHROMIUM AND COPPER ON SOME HAEMATOLOGICAL PARAMETERS AND SERUM PROTEINS IN BROILERS

    Directory of Open Access Journals (Sweden)

    M. Tariq Javed, F, Ahmad. N, Z, Rafique1 and M, Bashir

    2003-01-01

    Full Text Available Effects of higher levels of chromium alone and in combination with copper were investigated in broiler chicks divided into seven equal groups viz. A, B, C, D, E, F and G. Group G served as control receiving no treatment. Groups A, B and F received chromium chloride at the rate of 2 g/kg and nicotinic acid 150 mg/kg feed while C, D and F received chromium chloride 8 g/kg and nicotinic acid 150mg/kg. Broilers of groups A and C received copper sulfate at the rate of 200 mg/kg while groups Band D 400 mg/kg feed. Haematological parameters studied revealed non-significant difference between treatment groups and control in haemoglobin concentration and total erythrocyte counts. However, only at 4th week, lower PCV was observed in birds fed higher levels of chromium chloride alone. Increase in TLC was observed in birds fed low chromium alone or' with low levels of copper. Results of serum proteins including total protein, albumin and globulin during first three weeks showed significantly or relatively lower values in treatment groups than control. Serum globulins generally revealed non-significant difference between treatment groups and control.

  15. Novel microscope-integrated stereoscopic heads-up display for intrasurgical optical coherence tomography

    Science.gov (United States)

    Shen, Liangbo; Carrasco-Zevallos, Oscar; Keller, Brenton; Viehland, Christian; Waterman, Gar; Hahn, Paul S.; Kuo, Anthony N.; Toth, Cynthia A.; Izatt, Joseph A.

    2016-01-01

    Intra-operative optical coherence tomography (OCT) requires a display technology which allows surgeons to visualize OCT data without disrupting surgery. Previous research and commercial intrasurgical OCT systems have integrated heads-up display (HUD) systems into surgical microscopes to provide monoscopic viewing of OCT data through one microscope ocular. To take full advantage of our previously reported real-time volumetric microscope-integrated OCT (4D MIOCT) system, we describe a stereoscopic HUD which projects a stereo pair of OCT volume renderings into both oculars simultaneously. The stereoscopic HUD uses a novel optical design employing spatial multiplexing to project dual OCT volume renderings utilizing a single micro-display. The optical performance of the surgical microscope with the HUD was quantitatively characterized and the addition of the HUD was found not to substantially effect the resolution, field of view, or pincushion distortion of the operating microscope. In a pilot depth perception subject study, five ophthalmic surgeons completed a pre-set dexterity task with 50.0% (SD = 37.3%) higher success rate and in 35.0% (SD = 24.8%) less time on average with stereoscopic OCT vision compared to monoscopic OCT vision. Preliminary experience using the HUD in 40 vitreo-retinal human surgeries by five ophthalmic surgeons is reported, in which all surgeons reported that the HUD did not alter their normal view of surgery and that live surgical maneuvers were readily visible in displayed stereoscopic OCT volumes. PMID:27231616

  16. Novel microscope-integrated stereoscopic heads-up display for intrasurgical optical coherence tomography.

    Science.gov (United States)

    Shen, Liangbo; Carrasco-Zevallos, Oscar; Keller, Brenton; Viehland, Christian; Waterman, Gar; Hahn, Paul S; Kuo, Anthony N; Toth, Cynthia A; Izatt, Joseph A

    2016-05-01

    Intra-operative optical coherence tomography (OCT) requires a display technology which allows surgeons to visualize OCT data without disrupting surgery. Previous research and commercial intrasurgical OCT systems have integrated heads-up display (HUD) systems into surgical microscopes to provide monoscopic viewing of OCT data through one microscope ocular. To take full advantage of our previously reported real-time volumetric microscope-integrated OCT (4D MIOCT) system, we describe a stereoscopic HUD which projects a stereo pair of OCT volume renderings into both oculars simultaneously. The stereoscopic HUD uses a novel optical design employing spatial multiplexing to project dual OCT volume renderings utilizing a single micro-display. The optical performance of the surgical microscope with the HUD was quantitatively characterized and the addition of the HUD was found not to substantially effect the resolution, field of view, or pincushion distortion of the operating microscope. In a pilot depth perception subject study, five ophthalmic surgeons completed a pre-set dexterity task with 50.0% (SD = 37.3%) higher success rate and in 35.0% (SD = 24.8%) less time on average with stereoscopic OCT vision compared to monoscopic OCT vision. Preliminary experience using the HUD in 40 vitreo-retinal human surgeries by five ophthalmic surgeons is reported, in which all surgeons reported that the HUD did not alter their normal view of surgery and that live surgical maneuvers were readily visible in displayed stereoscopic OCT volumes.

  17. A novel lentiviral scFv display library for rapid optimization and selection of high affinity antibodies.

    Science.gov (United States)

    Qudsia, Sehar; Merugu, Siva B; Mangukiya, Hitesh B; Hema, Negi; Wu, Zhenghua; Li, Dawei

    2018-04-30

    Antibody display libraries have become a popular technique to screen monoclonal antibodies for therapeutic purposes. An important aspect of display technology is to generate an optimization library by changing antibody affinity to antigen through mutagenesis and screening the high affinity antibody. In this study, we report a novel lentivirus display based optimization library antibody in which Agtuzumab scFv is displayed on cell membrane of HEK-293T cells. To generate an optimization library, hotspot mutagenesis was performed to achieve diverse antibody library. Based on sequence analysis of randomly selected clones, library size was estimated approximately to be 1.6 × 10 6 . Lentivirus display vector was used to display scFv antibody on cell surface and flow cytometery was performed to check the antibody affinity to antigen. Membrane bound scFv antibodies were then converted to secreted antibody through cre/loxP recombination. One of the mutant clones, M8 showed higher affinity to antigen in flow cytometery analysis. Further characterization of cellular and secreted scFv through western blot showed that antibody affinity was increased by three fold after mutagenesis. This study shows successful construction of a novel antibody library and suggests that hotspot mutagenesis could prove a useful and rapid optimization tool to generate similar libraries with various degree of antigen affinity. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. 27 CFR 6.55 - Display service.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Display service. 6.55 Section 6.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS âTIED-HOUSEâ Unlawful Inducements Paying for Advertising, Display Or...

  19. Druid, displaying root module used for linear collider detectors

    International Nuclear Information System (INIS)

    Ruan, M

    2012-01-01

    Based on the ROOT TEve/TGeo classes and the standard linear collider data structure, a dedicated linear collider event display has been developed. It supports the latest detector models for both International Linear Collider and Compact Linear Collider as well as the CALICE test beam prototypes. It can be used to visualise event information at the generation, simulation and reconstruction levels. Many options are provided in an intuitive interface. It has been heavily employed in a variety of analyses.

  20. Radon daughters and work at display devices

    International Nuclear Information System (INIS)

    Falk, R.; Nyblom, L.

    1986-01-01

    It has been shown that ions and electrically charged particles in the air can be transported in the electrostatic field between a face and a display device to either the face or the screen. Radon daughters can occur as ions, or sitting on charged particles. This prestudy shows that radon daughters were manifold concentrated on the face of a doll placed in front of a display device, or in a electrostatic field of the kind typical for displaying devices. The radiation dose, in the skin from the radon daughters in an ordinary office environment plus the addition caused by work at a display device, is not strong enough to cause skin damages alone. (BoK)

  1. A display to support knowledge based behavior

    International Nuclear Information System (INIS)

    Lindsay, R.W.

    1990-01-01

    A computerized display has been created for the Experimental Breeder Reactor II (EBR-II) that incorporates information from plant sensors in a thermodynamic model display. The display is designed to provide an operator with an overall view of the plant process as a heat engine. The thermodynamics of the plant are depicted through the use of ionic figures, animated by plant signals, that are related to the major plant components and systems such as the reactor, intermediate heat exchanger, secondary system, evaporators, superheaters, steam system, steam drum, and turbine-generator. This display supports knowledge based reasoning for the operator as well as providing the traditional rule and skill based behavior, and includes side benefits such a inherent signal validation

  2. A faster technique for rendering meshes in multiple display systems

    Science.gov (United States)

    Hand, Randall E.; Moorhead, Robert J., II

    2003-05-01

    Level of detail algorithms have widely been implemented in architectural VR walkthroughs and video games, but have not had widespread use in VR terrain visualization systems. This thesis explains a set of optimizations to allow most current level of detail algorithms run in the types of multiple display systems used in VR. It improves both the visual quality of the system through use of graphics hardware acceleration, and improves the framerate and running time through moifications to the computaitons that drive the algorithms. Using ROAM as a testbed, results show improvements between 10% and 100% on varying machines.

  3. 'Twisted' strings and higher level Kac-Moody representations

    International Nuclear Information System (INIS)

    Horvath, Z.; Palla, L.

    1989-01-01

    Using an orbifold-like construction the twisted sector of a closed string moving on GxG (with G simply laced) is determined. A level-two G current operating there is constructed explicitly. The decomposition of the twisted sector into products between appropriate conformal and level-two G representations is given if 2 rank G-2 dim G/(2+g)<1. (orig.)

  4. Optimizing height presentation for aircraft cockpit displays

    Science.gov (United States)

    Jordan, Chris S.; Croft, D.; Selcon, Stephen J.; Markin, H.; Jackson, M.

    1997-02-01

    This paper describes an experiment conducted to investigate the type of display symbology that most effectively conveys height information to users of head-down plan-view radar displays. The experiment also investigated the use of multiple information sources (redundancy) in the design of such displays. Subjects were presented with eight different height display formats. These formats were constructed from a control, and/or one, two, or three sources of redundant information. The three formats were letter coding, analogue scaling, and toggling (spatially switching the position of the height information from above to below the aircraft symbol). Subjects were required to indicate altitude awareness via a four-key, forced-choice keyboard response. Error scores and response times were taken as performance measures. There were three main findings. First, there was a significant performance advantage when the altitude information was presented above and below the symbol to aid the representation of height information. Second, the analogue scale, a line whose length indicated altitude, proved significantly detrimental to performance. Finally, no relationship was found between the number of redundant information sources employed and performance. The implications for future aircraft and displays are discussed in relation to current aircraft tactical displays and in the context of perceptual psychological theory.

  5. View interpolation for medical images on autostereoscopic displays

    NARCIS (Netherlands)

    Zinger, S.; Ruijters, D.; Do, Q.L.; With, de P.H.N.

    2012-01-01

    We present an approach for efficient rendering and transmitting views to a high-resolution autostereoscopic display for medical purposes. Displaying biomedical images on an autostereoscopic display poses different requirements than in a consumer case. For medical usage, it is essential that the

  6. Cholesteric Liquid Crystal Based Reflex Color Reflective Displays

    Science.gov (United States)

    Khan, Asad

    2012-02-01

    Bistable color cholesteric liquid crystal displays are unique LCDs that exhibit high reflectivity, good contrast, extremely low power operation, and are amenable to versatile roll-to-roll manufacturing. The display technology, now branded as Reflex has been in commercialized products since 1996. It has been the subject of extensive research and development globally by a variety of parties in both academic and industrial settings. Today, the display technology is in volume production for applications such as dedicated eWriters (Boogie Board), full color electronic skins (eSkin), and displays for smart cards. The flexibility comes from polymerization induced phase separation using unique materials unparalleled in any other display technology. The blend of monomers, polymers, cross linkers, and other components along with nematic liquid crystals and chiral dopants is created and processed in such ways so as to enable highly efficient manufactrable displays using ultra thin plastic substrates -- often as thin as 50μm. Other significant aspects include full color by stacking or spatial separation, night vision capability, ultra high resolution, as well as active matrix capabilities. Of particular note is the stacking approach of Reflex based displays to show full color. This approach for reflective color displays is unique to this technology. Owing to high transparency in wavelength bands outside the selective reflection band, three primarily color layers can be stacked on top of each other and reflect without interfering with other layers. This highly surprising architecture enables the highest reflectivity of any other reflective electronic color display technology. The optics, architecture, electro-topics, and process techniques will be discussed. This presentation will focus on the physics of the core technology and color, it's evolution from rigid glass based displays to flexible displays, development of products from the paradigm shifting concepts to consumer

  7. Interactive editing program using display

    International Nuclear Information System (INIS)

    Lang, I.; Ehsenski, J.; Namsraj, Yu.; Fefilov, B.V.

    1976-01-01

    A general description is given as well as principal functions are considered of 'DOSE' interactive editor program with a display involved. The program has been elaborated for TRA/1-1001 computer. This program enables one to edit and correct texts in algorithmical languages on a raster display screen as well as to provide perforated tapes for their further usage. 'DOSE' program is regarded as a basic program system for a set of TRA/1 and MINSK-32 computers

  8. Changing conditions require a higher level of entrepreneurship by farmers: use of an interactive strategic management tool

    NARCIS (Netherlands)

    Beldman, A.C.G.; Lakner, D.; Smit, A.B.

    2013-01-01

    Changing conditions require a higher level of entrepreneurship by farmers. The method of interactive strategic management (ISM) has been developed to support farmers in developing strategic skills. The method is based on three principles: (1) emphasis is on the entrepreneur; (2) interaction with the

  9. Small - Display Cartography

    DEFF Research Database (Denmark)

    Nissen, Flemming; Hvas, Anders; Münster-Swendsen, Jørgen

    Service Communication and finally, Part IV: Concluding remarks and topics for further research on small-display cartography. Part II includes a separate Appendix D consisting of a cartographic design specification. Part III includes a separate Appendix C consisting of a schema specification, a separate...

  10. Wired World-Wide Web Interactive Remote Event Display

    Energy Technology Data Exchange (ETDEWEB)

    De Groot, Nicolo

    2003-05-07

    WIRED (World-Wide Web Interactive Remote Event Display) is a framework, written in the Java{trademark} language, for building High Energy Physics event displays. An event display based on the WIRED framework enables users of a HEP collaboration to visualize and analyze events remotely using ordinary WWW browsers, on any type of machine. In addition, event displays using WIRED may provide the general public with access to the research of high energy physics. The recent introduction of the object-oriented Java{trademark} language enables the transfer of machine independent code across the Internet, to be safely executed by a Java enhanced WWW browser. We have employed this technology to create a remote event display in WWW. The combined Java-WWW technology hence assures a world wide availability of such an event display, an always up-to-date program and a platform independent implementation, which is easy to use and to install.

  11. Higher Education

    African Journals Online (AJOL)

    Kunle Amuwo: Higher Education Transformation: A Paradigm Shilt in South Africa? ... ty of such skills, especially at the middle management levels within the higher ... istics and virtues of differentiation and diversity. .... may be forced to close shop for lack of capacity to attract ..... necessarily lead to racial and gender equity,.

  12. Why is mean sea level along the Indian coast higher in the Bay of Bengal than in the Arabian Sea?

    Digital Repository Service at National Institute of Oceanography (India)

    Shankar, D.; Shetye, S.R.

    Levelling observations conducted during the Great Trigonometrical Survey of India (1858-1909) and subsequent observations showed that mean sea level along the coast of India is higher in the Bay of Bengal than in the Arabian Sea, the difference...

  13. Integrated multimodal human-computer interface and augmented reality for interactive display applications

    Science.gov (United States)

    Vassiliou, Marius S.; Sundareswaran, Venkataraman; Chen, S.; Behringer, Reinhold; Tam, Clement K.; Chan, M.; Bangayan, Phil T.; McGee, Joshua H.

    2000-08-01

    We describe new systems for improved integrated multimodal human-computer interaction and augmented reality for a diverse array of applications, including future advanced cockpits, tactical operations centers, and others. We have developed an integrated display system featuring: speech recognition of multiple concurrent users equipped with both standard air- coupled microphones and novel throat-coupled sensors (developed at Army Research Labs for increased noise immunity); lip reading for improving speech recognition accuracy in noisy environments, three-dimensional spatialized audio for improved display of warnings, alerts, and other information; wireless, coordinated handheld-PC control of a large display; real-time display of data and inferences from wireless integrated networked sensors with on-board signal processing and discrimination; gesture control with disambiguated point-and-speak capability; head- and eye- tracking coupled with speech recognition for 'look-and-speak' interaction; and integrated tetherless augmented reality on a wearable computer. The various interaction modalities (speech recognition, 3D audio, eyetracking, etc.) are implemented a 'modality servers' in an Internet-based client-server architecture. Each modality server encapsulates and exposes commercial and research software packages, presenting a socket network interface that is abstracted to a high-level interface, minimizing both vendor dependencies and required changes on the client side as the server's technology improves.

  14. When authenticity matters most: Physicians' regulation of emotional display and patient satisfaction.

    Science.gov (United States)

    Yagil, Dana; Shnapper-Cohen, Moran

    2016-10-01

    The emotions expressed by physicians in medical encounters have significant impact on health outcomes and patient satisfaction. This study explored how physicians' regulation of displayed emotions affects patients' satisfaction, under low and high levels of patient distress and length of physician-patient acquaintance. Questionnaires were administered to 46 physicians and 230 of their patients (before and after the medical encounter) in outpatient clinics of two hospitals. Data were analyzed with hierarchical linear modeling which takes the nested data structure into account. We found a significant interaction effect of physician regulation of displayed emotions and patient distress on satisfaction: When distress was high, physician regulation of emotions was negatively related to patient satisfaction. The results also show a significant interaction effect of physician regulation of displayed emotions and length of physician-patient acquaintance: With a longer acquaintance, physician regulation of emotions was negatively related to patient satisfaction. The effect of the physicians' emotional display on patient satisfaction depends on contextual factors, such as patient distress and length of physician-patient acquaintance, which affect patients' emotional needs and expectations. When patients have high emotional involvement in the encounter it is suggested that physicians consider presenting genuine emotions to patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Measurement of the Jones matrix of liquid crystal displays using a common path interferometer

    International Nuclear Information System (INIS)

    Sarkadi, Tamás; Koppa, Pál

    2011-01-01

    We propose a robust interferometric method to measure the Jones matrix of polarization components, especially liquid crystal displays. Phase values are measured by a simple common path interferometer containing a birefringent crystal as beam splitter and a polarizer as beam combiner. This solution eliminates the sensitivity of traditional interferometric techniques to vibration, temperature variation or wavefront distortion. The proposed phase measurement method is applicable to the measurement of both spatially homogeneous and binary modulated states, thus the modulation transfer function and inter-pixel interference can also be studied. We demonstrate this technique by the measurement of a liquid crystal on silicon display. The resulting Jones matrix, as a function of displayed gray level, can be efficiently embedded in any numeric model of an optical system containing the analyzed spatial light modulator

  16. Optimizing direct response in Internet display advertising

    OpenAIRE

    Aksakallı, Vural

    2013-01-01

    Internet display advertising has grown into a multi-billion dollar a year global industry and direct response campaigns account for about three-quarters of all Internet display advertising. In such campaigns, advertisers reach out to a target audience via some form of a visual advertisement (hereinafter also called “ad”) to maximize short-term sales revenue. In this study, we formulate an advertiser’s revenue maximization problem in direct response Internet display advertisement campaigns as ...

  17. Online Display Advertising Causal Attribution and Evaluation

    OpenAIRE

    Barajas Zamora, Joel

    2015-01-01

    The allocation of a given budget to online display advertising as a marketing channel has motivated the development of statistical methods to measure its effectiveness. Recent studies show that display advertising often triggers online users to search for more information on products. Eventually, many of these users convert at the advertiser’s website. A key challenge is to measure the effectiveness of display advertising when users are exposed to multiple unknown advertising channels.We deve...

  18. Methods and apparatus for transparent display using scattering nanoparticles

    Science.gov (United States)

    Hsu, Chia Wei; Qiu, Wenjun; Zhen, Bo; Shapira, Ofer; Soljacic, Marin

    2016-05-10

    Transparent displays enable many useful applications, including heads-up displays for cars and aircraft as well as displays on eyeglasses and glass windows. Unfortunately, transparent displays made of organic light-emitting diodes are typically expensive and opaque. Heads-up displays often require fixed light sources and have limited viewing angles. And transparent displays that use frequency conversion are typically energy inefficient. Conversely, the present transparent displays operate by scattering visible light from resonant nanoparticles with narrowband scattering cross sections and small absorption cross sections. More specifically, projecting an image onto a transparent screen doped with nanoparticles that selectively scatter light at the image wavelength(s) yields an image on the screen visible to an observer. Because the nanoparticles scatter light at only certain wavelengths, the screen is practically transparent under ambient light. Exemplary transparent scattering displays can be simple, inexpensive, scalable to large sizes, viewable over wide angular ranges, energy efficient, and transparent simultaneously.

  19. Higher levels of circulating chemerin in both lean and obese patients with polycystic ovary syndrome.

    Science.gov (United States)

    Ademoglu, E; Berberoglu, Z; Carlioglu, A; Dellal, F; Gorar, S; Alphan, Z; Uysal, S; Karakurt, F

    2014-12-01

    The aim of this paper was to compare serum chemerin levels in nonobese and overweight/obese patients with polycystic ovary syndrome (PCOS) with lean controls. Seventy women with newly diagnosed or untreated PCOS and 38 age-matched nonobese healthy controls were enrolled in the present study. Participants with PCOS were categorized as nonobese (Body Mass Index [BMI] PCOS group than in nonobese PCOS women but did not reach statistical significance. Nonobese healthy controls had significantly lower chemerin levels than two PCOS groups (Pwomen with PCOS than in other two groups. Also, these two parameters were higher in lean patients with PCOS than in healthy controls (PPCOS women but also in nonobese PCOS women. The physiological significance of elevated serum chemerin in PCOS remains unclear.

  20. Hijab and Depression: Does the Islamic Practice of Veiling Predict Higher Levels of Depressive Symptoms?

    Science.gov (United States)

    Hodge, David R; Husain, Altaf; Zidan, Tarek

    2017-07-01

    Hijab or veiling is commonly practiced by Muslim women but remains controversial in the broader secular society. Some Western feminists argue that veiling is an oppressive behavior that negatively affects women by, for example, engendering depression. This article tests this hypothesis with a national sample of American Muslim women (N = 194). The results of the regression analysis did not support the hypothesis. Indeed, women who veiled more frequently reported lower, rather than higher, levels of depressive symptoms. In other words, wearing the hijab appears to be a protective factor in the area of depression. Given the prevalence of depression among women, the results have important implications for practice with Muslim women at both the micro and the macro levels. © 2017 National Association of Social Workers.